Sample records for fire safety analysis

  1. 49 CFR 238.103 - Fire safety.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Fire safety. 238.103 Section 238.103... § 238.103 Fire safety. (a) Materials. (1) Materials used in constructing a passenger car or a cab of a... section at the time it was tested. (c) Fire safety analysis for procuring new passenger cars and...

  2. 49 CFR 238.103 - Fire safety.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Fire safety. 238.103 Section 238.103... § 238.103 Fire safety. (a) Materials. (1) Materials used in constructing a passenger car or a cab of a... section at the time it was tested. (c) Fire safety analysis for procuring new passenger cars and...

  3. 49 CFR 238.103 - Fire safety.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Fire safety. 238.103 Section 238.103... § 238.103 Fire safety. (a) Materials. (1) Materials used in constructing a passenger car or a cab of a... section at the time it was tested. (c) Fire safety analysis for procuring new passenger cars and...

  4. Heat Transfer Principles in Thermal Calculation of Structures in Fire

    PubMed Central

    Zhang, Chao; Usmani, Asif

    2016-01-01

    Structural fire engineering (SFE) is a relatively new interdisciplinary subject, which requires a comprehensive knowledge of heat transfer, fire dynamics and structural analysis. It is predominantly the community of structural engineers who currently carry out most of the structural fire engineering research and design work. The structural engineering curriculum in universities and colleges do not usually include courses in heat transfer and fire dynamics. In some institutions of higher education, there are graduate courses for fire resistant design which focus on the design approaches in codes. As a result, structural engineers who are responsible for structural fire safety and are competent to do their jobs by following the rules specified in prescriptive codes may find it difficult to move toward performance-based fire safety design which requires a deep understanding of both fire and heat. Fire safety engineers, on the other hand, are usually focused on fire development and smoke control, and may not be familiar with the heat transfer principles used in structural fire analysis, or structural failure analysis. This paper discusses the fundamental heat transfer principles in thermal calculation of structures in fire, which might serve as an educational guide for students, engineers and researchers. Insights on problems which are commonly ignored in performance based fire safety design are also presented. PMID:26783379

  5. Motorcoach and school bus fire safety analysis.

    DOT National Transportation Integrated Search

    2016-11-01

    This report documents a motorcoach and school bus fire safety analysis performed by the John A. Volpe National Transportation Systems Center (Volpe) for the Federal Motor Carrier Safety Administration. This report aims to: 1) identify the causes, fre...

  6. Motorcoach and school bus fire safety analysis : technology brief.

    DOT National Transportation Integrated Search

    2016-11-01

    In 2009, the Federal Motor Carrier Safety Administration (FMCSA) published findings from a study entitled Motorcoach Fire Safety Analysis. The objective of this study was to gather and analyze information regarding the causes, frequency, and se...

  7. 41 CFR 102-80.110 - What must an equivalent level of safety analysis indicate?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., and reliability of all building systems impacting fire growth, occupant knowledge of the fire, and... Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Accident and Fire Prevention Equivalent Level of Safety...

  8. 41 CFR 102-80.110 - What must an equivalent level of safety analysis indicate?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., and reliability of all building systems impacting fire growth, occupant knowledge of the fire, and... Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Accident and Fire Prevention Equivalent Level of Safety...

  9. 41 CFR 102-80.110 - What must an equivalent level of safety analysis indicate?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., and reliability of all building systems impacting fire growth, occupant knowledge of the fire, and... Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Accident and Fire Prevention Equivalent Level of Safety...

  10. 41 CFR 102-80.110 - What must an equivalent level of safety analysis indicate?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., and reliability of all building systems impacting fire growth, occupant knowledge of the fire, and... Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Accident and Fire Prevention Equivalent Level of Safety...

  11. Comparing the performance of residential fire sprinklers with other life-safety technologies.

    PubMed

    Butry, David T

    2012-09-01

    Residential fire sprinklers have long proven themselves as life-safety technologies to the fire service community. Yet, about 1% of all one- and two-family dwelling fires occur in homes protected by sprinklers. It has been argued that measured sprinkler performance has ignored factors confounding the relationship between sprinkler use and performance. In this analysis, sprinkler performance is measured by comparing 'like' structure fires, while conditioning on smoke detection technology and neighborhood housing and socioeconomic conditions, using propensity score matching. Results show that residential fire sprinklers protect occupant and firefighter health and safety, and are comparable to other life-safety technologies. Published by Elsevier Ltd.

  12. Fire safety in transit systems fault tree analysis

    DOT National Transportation Integrated Search

    1981-09-01

    Fire safety countermeasures applicable to transit vehicles are identified and evaluated. This document contains fault trees which illustrate the sequences of events which may lead to a transit-fire related casualty. A description of the basis for the...

  13. Fire Safety of Passenger Trains : Phase II : Application of Fire Hazard Analysis Techniques

    DOT National Transportation Integrated Search

    2001-12-01

    On May 12, 1999, the Federal Railroad Administration (FRA) issued regulations for passenger rail equipment safety standards that included small-scale fire tests and performance criteria to evaluate the flammability and smoke characteristics of indivi...

  14. Fire safety of passenger trains. Phase II, Application of fire hazard analysis techniques.

    DOT National Transportation Integrated Search

    2001-12-01

    On May 12, 1999, the Federal Railroad Administration (FRA) issued regulations for passenger rail equipment safety standards that included small-scale fire tests and performance criteria to evaluate the flammability and smoke characteristics of indivi...

  15. Investment appraisal using quantitative risk analysis.

    PubMed

    Johansson, Henrik

    2002-07-01

    Investment appraisal concerned with investments in fire safety systems is discussed. Particular attention is directed at evaluating, in terms of the Bayesian decision theory, the risk reduction that investment in a fire safety system involves. It is shown how the monetary value of the change from a building design without any specific fire protection system to one including such a system can be estimated by use of quantitative risk analysis, the results of which are expressed in terms of a Risk-adjusted net present value. This represents the intrinsic monetary value of investing in the fire safety system. The method suggested is exemplified by a case study performed in an Avesta Sheffield factory.

  16. The Safety Analysis of Shipborne Ammunition in Fire Environment

    NASA Astrophysics Data System (ADS)

    Ren, Junpeng; Wang, Xudong; Yue, Pengfei

    2017-12-01

    The safety of Ammunition has always been the focus of national military science and technology issues. And fire is one of the major safety threats to the ship’s ammunition storage environment, In this paper, Mk-82 shipborne aviation bomb has been taken as the study object, simulated the whole process of fire by using the FDS (Fire Detection System) software. According to the simulation results of FDS, ANSYS software was used to simulate the temperature field of Mk-82 carrier-based aviation bomb under fire environment, and the safety of aviation bomb in fire environment was analyzed. The result shows that the aviation bombs under the fire environment can occur the combustion or explosion after 70s constant cook-off, and it was a huge threat to the ship security.

  17. Motorcoach fire safety analysis : the causes, frequency, and severity of motorcoach fires in the United States

    DOT National Transportation Integrated Search

    2012-06-28

    The Federal Motor Carrier Safety Administrations (FMCSA) mission is to reduce crashes, injuries, and fatalities on our nations roads involving motor vehicles, and to further its work the agency set out to identify ways to reduce motorcoach fire...

  18. Ring the Alarm! A Memo to the Schools on Fire and Human Beings.

    ERIC Educational Resources Information Center

    Educational Facilities Labs., Inc., New York, NY.

    An analysis is presented of the handling of the human elements in fire safety. Emphasis is given to considerations such as how fires kill children, the school's responsibility for fire safety, causes of human failure, and the necessity for organized emergency programs and drills. Also included is a check list of items concerned with protection…

  19. Quantitative assessment of building fire risk to life safety.

    PubMed

    Guanquan, Chu; Jinhua, Sun

    2008-06-01

    This article presents a quantitative risk assessment framework for evaluating fire risk to life safety. Fire risk is divided into two parts: probability and corresponding consequence of every fire scenario. The time-dependent event tree technique is used to analyze probable fire scenarios based on the effect of fire protection systems on fire spread and smoke movement. To obtain the variation of occurrence probability with time, Markov chain is combined with a time-dependent event tree for stochastic analysis on the occurrence probability of fire scenarios. To obtain consequences of every fire scenario, some uncertainties are considered in the risk analysis process. When calculating the onset time to untenable conditions, a range of fires are designed based on different fire growth rates, after which uncertainty of onset time to untenable conditions can be characterized by probability distribution. When calculating occupant evacuation time, occupant premovement time is considered as a probability distribution. Consequences of a fire scenario can be evaluated according to probability distribution of evacuation time and onset time of untenable conditions. Then, fire risk to life safety can be evaluated based on occurrence probability and consequences of every fire scenario. To express the risk assessment method in detail, a commercial building is presented as a case study. A discussion compares the assessment result of the case study with fire statistics.

  20. 41 CFR 102-80.125 - Who has the responsibility for determining the acceptability of each equivalent level of safety...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... departments or other local authorities for use in developing pre-fire plans. ... Fire Prevention Equivalent Level of Safety Analysis § 102-80.125 Who has the responsibility for... acceptability must include a review of the fire protection engineer's qualifications, the appropriateness of the...

  1. 41 CFR 102-80.125 - Who has the responsibility for determining the acceptability of each equivalent level of safety...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... departments or other local authorities for use in developing pre-fire plans. ... Fire Prevention Equivalent Level of Safety Analysis § 102-80.125 Who has the responsibility for... acceptability must include a review of the fire protection engineer's qualifications, the appropriateness of the...

  2. 41 CFR 102-80.125 - Who has the responsibility for determining the acceptability of each equivalent level of safety...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... departments or other local authorities for use in developing pre-fire plans. ... Fire Prevention Equivalent Level of Safety Analysis § 102-80.125 Who has the responsibility for... acceptability must include a review of the fire protection engineer's qualifications, the appropriateness of the...

  3. 41 CFR 102-80.125 - Who has the responsibility for determining the acceptability of each equivalent level of safety...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... departments or other local authorities for use in developing pre-fire plans. ... Fire Prevention Equivalent Level of Safety Analysis § 102-80.125 Who has the responsibility for... acceptability must include a review of the fire protection engineer's qualifications, the appropriateness of the...

  4. 41 CFR 102-80.125 - Who has the responsibility for determining the acceptability of each equivalent level of safety...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... departments or other local authorities for use in developing pre-fire plans. ... Fire Prevention Equivalent Level of Safety Analysis § 102-80.125 Who has the responsibility for... acceptability must include a review of the fire protection engineer's qualifications, the appropriateness of the...

  5. Fire safety distances for open pool fires

    NASA Astrophysics Data System (ADS)

    Sudheer, S.; Kumar, Lokendra; Manjunath, B. S.; Pasi, Amit; Meenakshi, G.; Prabhu, S. V.

    2013-11-01

    Fire accidents that carry huge loss with them have increased in the previous two decades than at any time in the history. Hence, there is a need for understanding the safety distances from different fires with different fuels. Fire safety distances are computed for different open pool fires. Diesel, gasoline and hexane are used as fuels for circular pool diameters of 0.5 m, 0.7 m and 1.0 m. A large square pool fire of 4 m × 4 m is also conducted with diesel as a fuel. All the prescribed distances in this study are purely based on the thermal analysis. IR camera is used to get the thermal images of pool fires and there by the irradiance at different locations is computed. The computed irradiance is presented with the threshold heat flux limits for human beings.

  6. Using modeling and rehearsal to teach fire safety to children with autism.

    PubMed

    Garcia, David; Dukes, Charles; Brady, Michael P; Scott, Jack; Wilson, Cynthia L

    2016-09-01

    We evaluated the efficacy of an instructional procedure to teach young children with autism to evacuate settings and notify an adult during a fire alarm. A multiple baseline design across children showed that an intervention that included modeling, rehearsal, and praise was effective in teaching fire safety skills. Safety skills generalized to novel settings and maintained during a 5-week follow-up in both training and generalization settings. © 2016 Society for the Experimental Analysis of Behavior.

  7. Optimization of Skill Retention in the U. S. Army through Initial Training Analysis and Design: Skill Sustainment Exercises. Volume 3.

    DTIC Science & Technology

    1983-05-01

    Firing data cards. PROCEDURES I. Prior to live fire exercises all firers must be oriented on range procedures. 2. Preparatory marksmanship training...Ordnance detail. 2. Range safety officer. 7. Medical personnel. 3. Firing line safety NCOs. 8. Control tower operators. i 4. Scorer (I per firer ). 9. Pit...phones and wire (for PIT commo). PROCEDURES I. Prior to live fire exercises, all firers must be oriented on range procedures. 2. Scorers are responsible

  8. A qualitative evaluation of fire safety education programs for older adults.

    PubMed

    Diekman, Shane T; Stewart, Tamara A; Teh, S Leesia; Ballesteros, Michael F

    2010-03-01

    This article presents a qualitative evaluation of six fire safety education programs for older adults delivered by public fire educators. Our main aims were to explore how these programs are implemented and to determine important factors that may lead to program success, from the perspectives of the public fire educators and the older adults. For each program, we interviewed the public fire educator(s), observed the program in action, and conducted focus groups with older adults attending the program. Analysis revealed three factors that were believed to facilitate program success (established relationships with the older adult community, rapport with older adult audiences, and presentation relevance) as well as three challenges (lack of a standardized curriculum and program implementation strategies, attendance difficulties, and physical limitations due to age). More fire safety education should be developed for older adult populations. For successful programs, public fire educators should address the specific needs of their local older adult community.

  9. Analysis of the Influence of Construction Insulation Systems on Public Safety in China

    PubMed Central

    Zhang, Guowei; Zhu, Guoqing; Zhao, Guoxiang

    2016-01-01

    With the Government of China’s proposed Energy Efficiency Regulations (GB40411-2007), the implementation of external insulation systems will be mandatory in China. The frequent external insulation system fires cause huge numbers of casualties and extensive property damage and have rapidly become a new hot issue in construction evacuation safety in China. This study attempts to reconstruct an actual fire scene and propose a quantitative risk assessment method for upward insulation system fires using thermal analysis tests and large eddy simulations (using the Fire Dynamics Simulator (FDS) software). Firstly, the pyrolysis and combustion characteristics of Extruded polystyrene board (XPS panel), such as ignition temperature, combustion heat, limiting oxygen index, thermogravimetric analysis and thermal radiation analysis were studied experimentally. Based on these experimental data, large eddy simulation was then applied to reconstruct insulation system fires. The results show that upward insulation system fires could be accurately reconstructed by using thermal analysis test and large eddy simulation. The spread of insulation material system fires in the vertical direction is faster than that in the horizontal direction. Moreover, we also find that there is a possibility of flashover in enclosures caused by insulation system fires as the smoke temperature exceeds 600 °C. The simulation methods and experimental results obtained in this paper could provide valuable references for fire evacuation, hazard assessment and fire resistant construction design studies. PMID:27589774

  10. Analysis of the Influence of Construction Insulation Systems on Public Safety in China.

    PubMed

    Zhang, Guowei; Zhu, Guoqing; Zhao, Guoxiang

    2016-08-30

    With the Government of China's proposed Energy Efficiency Regulations (GB40411-2007), the implementation of external insulation systems will be mandatory in China. The frequent external insulation system fires cause huge numbers of casualties and extensive property damage and have rapidly become a new hot issue in construction evacuation safety in China. This study attempts to reconstruct an actual fire scene and propose a quantitative risk assessment method for upward insulation system fires using thermal analysis tests and large eddy simulations (using the Fire Dynamics Simulator (FDS) software). Firstly, the pyrolysis and combustion characteristics of Extruded polystyrene board (XPS panel), such as ignition temperature, combustion heat, limiting oxygen index, thermogravimetric analysis and thermal radiation analysis were studied experimentally. Based on these experimental data, large eddy simulation was then applied to reconstruct insulation system fires. The results show that upward insulation system fires could be accurately reconstructed by using thermal analysis test and large eddy simulation. The spread of insulation material system fires in the vertical direction is faster than that in the horizontal direction. Moreover, we also find that there is a possibility of flashover in enclosures caused by insulation system fires as the smoke temperature exceeds 600 °C. The simulation methods and experimental results obtained in this paper could provide valuable references for fire evacuation, hazard assessment and fire resistant construction design studies.

  11. 41 CFR 102-80.130 - Who must perform the equivalent level of safety analysis?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-SAFETY AND ENVIRONMENTAL MANAGEMENT Accident and Fire Prevention Equivalent Level of Safety Analysis... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Who must perform the equivalent level of safety analysis? 102-80.130 Section 102-80.130 Public Contracts and Property Management...

  12. Fire behavior and risk analysis in spacecraft

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Sacksteder, Kurt R.

    1988-01-01

    Practical risk management for present and future spacecraft, including space stations, involves the optimization of residual risks balanced by the spacecraft operational, technological, and economic limitations. Spacecraft fire safety is approached through three strategies, in order of risk: (1) control of fire-causing elements, through exclusion of flammable materials for example; (2) response to incipient fires through detection and alarm; and (3) recovery of normal conditions through extinguishment and cleanup. Present understanding of combustion in low gravity is that, compared to normal gravity behavior, fire hazards may be reduced by the absence of buoyant gas flows yet at the same time increased by ventilation flows and hot particle expulsion. This paper discusses the application of low-gravity combustion knowledge and appropriate aircraft analogies to fire detection, fire fighting, and fire-safety decisions for eventual fire-risk management and optimization in spacecraft.

  13. Fire hazard analysis for Plutonium Finishing Plant complex

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MCKINNIS, D.L.

    1999-02-23

    A fire hazards analysis (FHA) was performed for the Plutonium Finishing Plant (PFP) Complex at the Department of Energy (DOE) Hanford site. The scope of the FHA focuses on the nuclear facilities/structures in the Complex. The analysis was conducted in accordance with RLID 5480.7, [DOE Directive RLID 5480.7, 1/17/94] and DOE Order 5480.7A, ''Fire Protection'' [DOE Order 5480.7A, 2/17/93] and addresses each of the sixteen principle elements outlined in paragraph 9.a(3) of the Order. The elements are addressed in terms of the fire protection objectives stated in paragraph 4 of DOE 5480.7A. In addition, the FHA also complies with WHC-CM-4-41,more » Fire Protection Program Manual, Section 3.4 [1994] and WHC-SD-GN-FHA-30001, Rev. 0 [WHC, 1994]. Objectives of the FHA are to determine: (1) the fire hazards that expose the PFP facilities, or that are inherent in the building operations, (2) the adequacy of the fire safety features currently located in the PFP Complex, and (3) the degree of compliance of the facility with specific fire safety provisions in DOE orders, related engineering codes, and standards.« less

  14. Can fire safety in hotels be improved? Results from the survey of a panel of experts in Spain.

    PubMed

    Rubio-Romero, Juan Carlos; Márquez-Sierra, Francisco; Suárez-Cebador, Manuel

    2016-06-08

    The hotel industry is an important driver of the European labour market with over 250,000 hotels employing some 2 million people. In Spain, 240 workers were injured by fires in hotels from 2004 to 2008. Fire is considered to be the most important risk in the hotel industry, but the lack of an EU-wide data recording system for hotels makes it difficult to give exact figures for fire events. We analysed the state of fire prevention systems in hotels in Spain with the aim of proposing strategies to improve fire safety. A 10-item questionnaire was administered from 2007 to 2009 to 15 Spanish experts in fire safety. The questions were measured using a Likert scale and classified into 4 sections: current state of installations, influence of establishment characteristics, application of regulations and priority ranking of actions. Descriptive statistics summarized the data and t-tests evaluated the agreement foreach statement in the questionnaire. The statistical analysis showed homogeneity in the responses by the experts in all four categories: current state of fire safety installations, influence of establishment characteristics, application of regulations, and priority of actions. There was consensus among the experts over the necessity to improve the enforcement of regulations and also regarding the existence of an association between the hotel category (in Spain they are ranked using a 1 to 5 "star" rating system) and the level of fire safety; hotels with a higher category had higher levels of safety. There is a need to identify ways to apply fire safety standards to older hotels so that they comply with new regulations, to standardize regulations for different regions and countries, to improve the maintenance of installations and equipment, to increase the effectiveness of inspections conducted by government bodies, and to raise the general awareness of stakeholders involved in hotel fire prevention.

  15. The effects of the lower ignition propensity cigarettes standard in Estonia: time-series analysis.

    PubMed

    Saar, Indrek

    2018-02-01

    In 2011, the lower ignition propensity (LIP) standard for cigarettes was implemented in the European Union. Evidence about the impact of that safety measure is scarce. The aim of this paper is to examine the effects of the LIP standard on fire safety in Estonia. The absolute level of smoking-related fire incidents and related deaths was modelled using dynamic time-series regression analysis. The data about house fire incidents for the 2007-2013 period were obtained from the Estonian Rescue Board. Implementation of the LIP standard has reduced the monthly level of smoking-related fires by 6.2 (p<0.01, SE=1.95) incidents and by 26% (p<0.01, SE=9%) when estimated on the log scale. Slightly weaker evidence was found about the fatality reduction effects of the LIP regulation. All results were confirmed through counterfactual models for non-smoking-related fire incidents and deaths. This paper indicates that implementation of the LIP cigarettes standard has improved fire safety in Estonia. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  16. Fire Safety - Multiple Languages

    MedlinePlus

    ... Arabic (العربية) Expand Section Fire Safety at Home - English PDF Fire Safety at Home - العربية (Arabic) PDF ... Bosnian (bosanski) Expand Section Fire Safety at Home - English PDF Fire Safety at Home - bosanski (Bosnian) PDF ...

  17. Safety in the Chemical Laboratory: Fire Safety and Fire Control in the Chemistry Laboratory.

    ERIC Educational Resources Information Center

    Wilbraham, A. C.

    1979-01-01

    Discusses fire safety and fire control in the chemistry laboratory. The combustion process, extinguishing equipment, extinguisher maintenance and location, and fire safety and practices are included. (HM)

  18. Large Scale Experiments on Spacecraft Fire Safety

    NASA Technical Reports Server (NTRS)

    Urban, David L.; Ruff, Gary A.; Minster, Olivier; Toth, Balazs; Fernandez-Pello, A. Carlos; T'ien, James S.; Torero, Jose L.; Cowlard, Adam J.; Legros, Guillaume; Eigenbrod, Christian; hide

    2012-01-01

    Full scale fire testing complemented by computer modelling has provided significant know how about the risk, prevention and suppression of fire in terrestrial systems (cars, ships, planes, buildings, mines, and tunnels). In comparison, no such testing has been carried out for manned spacecraft due to the complexity, cost and risk associated with operating a long duration fire safety experiment of a relevant size in microgravity. Therefore, there is currently a gap in knowledge of fire behaviour in spacecraft. The entire body of low-gravity fire research has either been conducted in short duration ground-based microgravity facilities or has been limited to very small fuel samples. Still, the work conducted to date has shown that fire behaviour in low-gravity is very different from that in normal-gravity, with differences observed for flammability limits, ignition delay, flame spread behaviour, flame colour and flame structure. As a result, the prediction of the behaviour of fires in reduced gravity is at present not validated. To address this gap in knowledge, a collaborative international project, Spacecraft Fire Safety, has been established with its cornerstone being the development of an experiment (Fire Safety 1) to be conducted on an ISS resupply vehicle, such as the Automated Transfer Vehicle (ATV) or Orbital Cygnus after it leaves the ISS and before it enters the atmosphere. A computer modelling effort will complement the experimental effort. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew removes the need for strict containment of combustion products. This will facilitate the possibility of examining fire behaviour on a scale that is relevant to spacecraft fire safety and will provide unique data for fire model validation. This unprecedented opportunity will expand the understanding of the fundamentals of fire behaviour in spacecraft. The experiment is being developed by an international topical team that is collaboratively defining the experiment requirements and performing supporting analysis, experimentation and technology development. This paper presents the objectives, status and concept of this project.

  19. Large Scale Experiments on Spacecraft Fire Safety

    NASA Technical Reports Server (NTRS)

    Urban, David; Ruff, Gary A.; Minster, Olivier; Fernandez-Pello, A. Carlos; Tien, James S.; Torero, Jose L.; Legros, Guillaume; Eigenbrod, Christian; Smirnov, Nickolay; Fujita, Osamu; hide

    2012-01-01

    Full scale fire testing complemented by computer modelling has provided significant knowhow about the risk, prevention and suppression of fire in terrestrial systems (cars, ships, planes, buildings, mines, and tunnels). In comparison, no such testing has been carried out for manned spacecraft due to the complexity, cost and risk associated with operating a long duration fire safety experiment of a relevant size in microgravity. Therefore, there is currently a gap in knowledge of fire behaviour in spacecraft. The entire body of low-gravity fire research has either been conducted in short duration ground-based microgravity facilities or has been limited to very small fuel samples. Still, the work conducted to date has shown that fire behaviour in low-gravity is very different from that in normal gravity, with differences observed for flammability limits, ignition delay, flame spread behaviour, flame colour and flame structure. As a result, the prediction of the behaviour of fires in reduced gravity is at present not validated. To address this gap in knowledge, a collaborative international project, Spacecraft Fire Safety, has been established with its cornerstone being the development of an experiment (Fire Safety 1) to be conducted on an ISS resupply vehicle, such as the Automated Transfer Vehicle (ATV) or Orbital Cygnus after it leaves the ISS and before it enters the atmosphere. A computer modelling effort will complement the experimental effort. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew removes the need for strict containment of combustion products. This will facilitate the possibility of examining fire behaviour on a scale that is relevant to spacecraft fire safety and will provide unique data for fire model validation. This unprecedented opportunity will expand the understanding of the fundamentals of fire behaviour in spacecraft. The experiment is being developed by an international topical team that is collaboratively defining the experiment requirements and performing supporting analysis, experimentation and technology development. This paper presents the objectives, status and concept of this project.

  20. Progress Report for Student Research: Fire Safety Skills for Mentally Retarded Children.

    ERIC Educational Resources Information Center

    Hayden, Mary F.; Lefcowitz, M. Jack

    A comprehensive fire safety skills program was evaluated with 32 moderately to mildly retarded adolescents. The program used a fire safety program manual and lessons in basic preventive fire skills, fire safety procedures, and fire escape skills. Across-group comparisons indicated differences in performance between males and females. Fire safety…

  1. An Operational Safety and Health Program.

    ERIC Educational Resources Information Center

    Uhorchak, Robert E.

    1983-01-01

    Describes safety/health program activities at Research Triangle Institute (North Carolina). These include: radioisotope/radiation and hazardous chemical/carcinogen use, training, monitoring, disposal; chemical waste management; air monitoring and analysis; medical program; fire safety/training, including emergency planning; Occupational Safety and…

  2. Spacecraft Fire Safety

    NASA Technical Reports Server (NTRS)

    Margle, Janice M. (Editor)

    1987-01-01

    Fire detection, fire standards and testing, fire extinguishment, inerting and atmospheres, fire-related medical science, aircraft fire safety, Space Station safety concerns, microgravity combustion, spacecraft material flammability testing, and metal combustion are among the topics considered.

  3. Large-Scale Spacecraft Fire Safety Experiments in ISS Resupply Vehicles

    NASA Technical Reports Server (NTRS)

    Ruff, Gary A.; Urban, David

    2013-01-01

    Our understanding of the fire safety risk in manned spacecraft has been limited by the small scale of the testing we have been able to conduct in low-gravity. Fire growth and spread cannot be expected to scale linearly with sample size so we cannot make accurate predictions of the behavior of realistic scale fires in spacecraft based on the limited low-g testing to date. As a result, spacecraft fire safety protocols are necessarily very conservative and costly. Future crewed missions are expected to be longer in duration than previous exploration missions outside of low-earth orbit and accordingly, more complex in terms of operations, logistics, and safety. This will increase the challenge of ensuring a fire-safe environment for the crew throughout the mission. Based on our fundamental uncertainty of the behavior of fires in low-gravity, the need for realistic scale testing at reduced gravity has been demonstrated. To address this concern, a spacecraft fire safety research project is underway to reduce the uncertainty and risk in the design of spacecraft fire safety systems by testing at nearly full scale in low-gravity. This project is supported by the NASA Advanced Exploration Systems Program Office in the Human Exploration and Operations Mission Directorate. The activity of this project is supported by an international topical team of fire experts from other space agencies to maximize the utility of the data and to ensure the widest possible scrutiny of the concept. The large-scale space flight experiment will be conducted on three missions; each in an Orbital Sciences Corporation Cygnus vehicle after it has deberthed from the ISS. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew allows the fire products to be released into the cabin. The tests will be fully automated with the data downlinked at the conclusion of the test before the Cygnus vehicle reenters the atmosphere. The international topical team is collaborating with the NASA team in the definition of the experiment requirements and performing supporting analysis, experimentation and technology development.

  4. The three Rs of fire safety, emergency action, and fire prevention planning: promoting safety at the worksite.

    PubMed

    Thompson, Marcella R

    2003-04-01

    Fire safety is of paramount importance for everyone. In many workplaces, the occupational health nurse's scope of practice encompasses safety related activities. Included within this role is the responsibility for fire safety, emergency action, and fire prevention planning. The Three Rs of fire safety, emergency action, and fire prevention plans are rules, responsibilities, and resources. Myriad building and fire safety codes, regulations, and standards exist with which an employer must comply. An employer's responsibility for installing, testing, inspecting, and maintaining fire safety related equipment is extensive. Emergency action and fire prevention planning begins with conducting a detailed physical survey and preparing site maps. It includes making key policy decisions, writing procedures, and training employees in those procedures by practicing and executing site drills. The best resources available for emergency planning are the local fire department and the property insurer. Planning ahead means an efficient emergency response if disaster strikes. It saves lives, limits property damage, and preserves the environment.

  5. 10 CFR 70.62 - Safety program and integrated safety analysis.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...; (iv) Potential accident sequences caused by process deviations or other events internal to the... of occurrence of each potential accident sequence identified pursuant to paragraph (c)(1)(iv) of this... have experience in nuclear criticality safety, radiation safety, fire safety, and chemical process...

  6. 10 CFR 70.62 - Safety program and integrated safety analysis.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...; (iv) Potential accident sequences caused by process deviations or other events internal to the... of occurrence of each potential accident sequence identified pursuant to paragraph (c)(1)(iv) of this... have experience in nuclear criticality safety, radiation safety, fire safety, and chemical process...

  7. 10 CFR 70.62 - Safety program and integrated safety analysis.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...; (iv) Potential accident sequences caused by process deviations or other events internal to the... of occurrence of each potential accident sequence identified pursuant to paragraph (c)(1)(iv) of this... have experience in nuclear criticality safety, radiation safety, fire safety, and chemical process...

  8. Improving freight fire safety : experiment testing and computer modeling to further development of mist-controlling additives for fire mitigation.

    DOT National Transportation Integrated Search

    2012-08-01

    With the purpose to minimize or prevent crash-induced fires in road and rail transportation, the : current interest in bio-derived and blended transportation fuels is increasing. Based on two years : of preliminary testing and analysis, it appears to...

  9. Partnerships: The Path to Improving Crisis Communication

    DTIC Science & Technology

    2007-03-01

    News Media Perceives Relationships with Public Safety.................32 Table 4. Public Safety SWOT Analysis ...opportunities and threats ( SWOT ) of the Seattle fire and police departments. The SWOT analysis is an assessment tool common to strategic planning for...requirements for training • Lack of strategic planning experience Table 4. Public Safety SWOT Analysis 46 Table 4 compares the strengths and

  10. The quest for all-purpose plants

    Treesearch

    Susan L. Frommer; David R. Weise

    1995-01-01

    The fire safety of a home in the wildland/urban interface is influenced by several factors-one of which is the presence and proximity of vegetation to the home. Landscaping may either provide a significant barrier to fire spread and thus potentially increase a home's fire safety or favor fire spread and reduce a home's fire safety. However, fire safety of...

  11. Field modeling of heat transfer in atrium

    NASA Astrophysics Data System (ADS)

    Nedryshkin, Oleg; Gravit, Marina; Bushuev, Nikolay

    2017-10-01

    The results of calculating fire risk are an important element in the system of modern fire safety assessment. The article reviews the work on the mathematical modeling of fire in the room. A comparison of different calculation models in the programs of fire risk assessment and fire modeling was performed. The results of full-scale fire tests and fire modeling in the FDS program are presented. The analysis of empirical and theoretical data on fire modeling is made, a conclusion is made about the modeling accuracy in the FDS program.

  12. Preventing Fire Death and Injury, Conducting a Fire Drill in a Group Home [and] When You Need a Fire Safety Expert. National Fire Safety Certification System. Continuing Education Program. Volume 1, Numbers 1-3.

    ERIC Educational Resources Information Center

    Walker, Bonnie

    Three booklets provide fire safety information for staff of residential facilities serving people with developmental disabilities. Booklets focus on: (1) preventing fire death and injury, (2) conducting a fire drill in a group home, and (3) the role of fire safety experts. The first booklet stresses the elimination of the following dangers:…

  13. Risk factors for rural residential fires.

    PubMed

    Allareddy, Veerasathpurush; Peek-Asa, Corinne; Yang, Jingzhen; Zwerling, Craig

    2007-01-01

    Rural households report high fire-related mortality and injury rates, but few studies have examined the risk factors for fires. This study aims to identify occupant and household characteristics that are associated with residential fires in a rural cohort. Of 1,005 households contacted in a single rural county, 691 (68.8%) agreed to participate. One household with missing information on a reported fire was excluded from the analysis. We used logistic regression to examine the independent association of occupant and household characteristics with reported fires, controlling for years lived in the residence. We also examined the association between the occurrence of previous fires and the adoption of safety measures. A total of 78 (11.3%) households reported a residential fire. Occupant characteristics that were associated with significantly higher odds of reported fires included the presence of an occupant with alcohol problems (OR = 1.82, 95% CI = 1.01-3.28) and being married (OR = 2.11, 95% CI = 1.14-3.91). Rural farm households were associated with significantly higher odds (OR = 1.72, 95% CI = 1.01-2.93) of reporting a fire when compared to residences in towns, after controlling for all other occupant and household characteristics. The presence of a fire extinguisher (OR = 2.00, 95% CI = 1.10-3.64) was the only fire safety measure that had a statistically significant association with reported fire. Rural farm households report higher incidences of fire when compared to households located in towns. Experiencing a fire is not associated with an increased likelihood of adopting safety measures to prevent injuries once a fire has started.

  14. 29 CFR Appendix A to Subpart P of... - Model Fire Safety Plan (Non-Mandatory)

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 7 2013-07-01 2013-07-01 false Model Fire Safety Plan (Non-Mandatory) A Appendix A to...—Model Fire Safety Plan (Non-Mandatory) Model Fire Safety Plan Note: This appendix is non-mandatory and provides guidance to assist employers in establishing a Fire Safety Plan as required in § 1915.502. Table...

  15. 29 CFR Appendix A to Subpart P to... - Model Fire Safety Plan (Non-Mandatory)

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 7 2012-07-01 2012-07-01 false Model Fire Safety Plan (Non-Mandatory) A Appendix A to...—Model Fire Safety Plan (Non-Mandatory) Model Fire Safety Plan Note: This appendix is non-mandatory and provides guidance to assist employers in establishing a Fire Safety Plan as required in § 1915.502. Table...

  16. 29 CFR Appendix A to Subpart P of... - Model Fire Safety Plan (Non-Mandatory)

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 7 2014-07-01 2014-07-01 false Model Fire Safety Plan (Non-Mandatory) A Appendix A to...—Model Fire Safety Plan (Non-Mandatory) Model Fire Safety Plan Note: This appendix is non-mandatory and provides guidance to assist employers in establishing a Fire Safety Plan as required in § 1915.502. Table...

  17. Coal Canyon Fire: Serious Accident Investigation Report

    Treesearch

    Charles L. Myers; Randy Draeger; Antoine Dixon; Cliff Dahl; Jim Saveland; Brad Mayhew; Gary Brown; Tony Petrilli; Ben Murphy; Erin Newman; Karen Mora; Tim Foley

    2012-01-01

    The purpose of this report is to present the facts proximal to the accident and share the Team's analysis in a way that enhances the reliability and resilience of Federal, State, and Local wildland fire organizations. The intent is to spur discussion and learning for those in the fire and safety community at all levels.

  18. Improving Freight Fire Safety: Analysis and Testing of Real Engine Conditions to Progress Development of Mist-controlling Additives for Fire Mitigation

    DOT National Transportation Integrated Search

    2009-12-01

    The formation of a fuel mist resulting from high shear stresses acting on the fuel during violent sloshing and tank rupture under the energy of a crash severely increases the occurrence and intensity of fires in transportation related accidents. In o...

  19. Fire safety

    Treesearch

    Robert H. White; Mark A. Dietenberger

    1999-01-01

    Fire safety is an important concern in all types of construction. The high level of national concern for fire safety is reflected in limitations and design requirements in building codes. These code requirements are discussed in the context of fire safety design and evaluation in the initial section of this chapter. Since basic data on fire behavior of wood products...

  20. Motorcoach Fire Safety Analysis.

    DOT National Transportation Integrated Search

    2009-07-01

    This purpose of this study was to collect and analyze information from Government, industry, and media sources on the causes, frequency, and severity of motorcoach fires in the U.S., and to identify potential risk reduction measures. The Volpe Center...

  1. Fire Signatures of Materials Used in Spacecraft Construction

    NASA Technical Reports Server (NTRS)

    Taylor, Christina

    2003-01-01

    The focus of my work this summer was fire safety, specifically determining fire signatures from the combustion of materials commonly found in the construction of spacecraft. This project was undertaken with the aim of addressing concerns for health and safety onboard spacecraft. Under certain conditions, burning electronics produce surprisingly large amounts of acrid smoke, release fine airborne particles and expel condensable aerosols. Similarly, some wire insulation and packing material evolves smoke when in contact with a hot surface. In the limited, enclosed space available on spacecraft, these combustion products may pose a nuisance at the very least - at worst, a hazard to health or equipment. There is also a concern for fire safety in early detection on spacecraft. Our goal for the summer was to determine the most effective methods to test the materials, develop a protocol for sampling, and generate samples for analysis. We restricted our testing to electronic components, packaging and insulation materials, and wire insulation materials.

  2. Critical safety assurance factors for manned spacecraft - A fire safety perspective

    NASA Technical Reports Server (NTRS)

    Rodney, George A.

    1990-01-01

    Safety assurance factors for manned spacecraft are discussed with a focus on the Space Station Freedom. A hazard scenario is provided to demonstrate a process commonly used by safety engineers and other analysts to identify onboard safety risks. Fire strategies are described, including a review of fire extinguishing agents being considered for the Space Station. Lessons learned about fire safety technology in other areas are also noted. NASA and industry research on fire safety applications is discussed. NASA's approach to ensuring safety for manned spacecraft is addressed in the context of its multidiscipline program.

  3. Fire Safety in Extraterrestrial Environments

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1998-01-01

    Despite rigorous fire-safety policies and practices, fire incidents are possible during lunar and Martian missions. Fire behavior and hence preventive and responsive safety actions in the missions are strongly influenced by the low-gravity environments in flight and on the planetary surfaces. This paper reviews the understanding and key issues of fire safety in the missions, stressing flame spread, fire detection, suppression, and combustion performance of propellants produced from Martian resources.

  4. Fire safety of wood construction

    Treesearch

    Robert H. White; Mark A. Dietenberger

    2010-01-01

    Fire safety is an important concern in all types of construction. The high level of national concern for fire safety is reflected in limitations and design requirements in building codes. These code requirements and related fire performance data are discussed in the context of fire safety design and evaluation in the initial section of this chapter. Because basic data...

  5. 40 CFR 30.18 - Hotel and motel fire safety.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 1 2013-07-01 2013-07-01 false Hotel and motel fire safety. 30.18... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 30.18 Hotel and motel fire safety. The Hotel and Motel Fire Safety Act of 1990 (Public Law 101-391) establishes a number of fire...

  6. 40 CFR 30.18 - Hotel and motel fire safety.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 1 2014-07-01 2014-07-01 false Hotel and motel fire safety. 30.18... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 30.18 Hotel and motel fire safety. The Hotel and Motel Fire Safety Act of 1990 (Public Law 101-391) establishes a number of fire...

  7. 40 CFR 30.18 - Hotel and motel fire safety.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 1 2012-07-01 2012-07-01 false Hotel and motel fire safety. 30.18... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 30.18 Hotel and motel fire safety. The Hotel and Motel Fire Safety Act of 1990 (Public Law 101-391) establishes a number of fire...

  8. 40 CFR 30.18 - Hotel and motel fire safety.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 1 2011-07-01 2011-07-01 false Hotel and motel fire safety. 30.18... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 30.18 Hotel and motel fire safety. The Hotel and Motel Fire Safety Act of 1990 (Public Law 101-391) establishes a number of fire...

  9. 40 CFR 30.18 - Hotel and motel fire safety.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Hotel and motel fire safety. 30.18... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 30.18 Hotel and motel fire safety. The Hotel and Motel Fire Safety Act of 1990 (Public Law 101-391) establishes a number of fire...

  10. 76 FR 10246 - Updating Fire Safety Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-24

    ... DEPARTMENT OF VETERANS AFFAIRS 38 CFR Parts 17 and 59 RIN 2900-AN57 Updating Fire Safety Standards... regulations and update the standards for VA approval of such facilities, including standards for fire safety... to ``RIN 2900-AN57--Updating Fire Safety [[Page 10247

  11. A study on fire spreading model for the safety distance between the neighborhood occupancies and historical buildings in Taiwan

    NASA Astrophysics Data System (ADS)

    Chen, C. H.; Chien, S. W.; Ho, M. C.

    2015-08-01

    Cultural heritages and historical buildings are vulnerable against severe threats from fire. Since the 1970s, ten fire-spread events involving historic buildings have occurred in Taiwan, affecting a total of 132 nearby buildings. Developed under the influence of traditional Taiwanese culture, historic buildings in Taiwan are often built using non-fire resistant brick-wood structure and located in proximity to residential occupancies. Fire outbreak in these types of neighborhood will lead to severe damage of antiquities, leaving only unrecoverable historical imagery. This study is aimed to investigate the minimal safety distance required between a historical building and its surroundings in order to reduce the risk of external fire. This study is based on literature analysis and the fire spread model using a Fire Dynamics Simulator. The selected target is Jingmei Temple in Taipei City. This study explored local geography to identify patterns behind historical buildings distribution. In the past, risk reduction engineering for cultural heritages and historical buildings focused mainly on fire equipment and the available personnel with emergency response ability, and little attention was given to external fire risks and the affected damage. Through discussions on the required safety distance, this research provides guidelines for the following items: management of neighborhoods with historical buildings and consultation between the protection of cultural heritages and disaster prevention, reducing the frequency and extent of fire damages, and preserving cultural resource.

  12. Fire and worker health and safety: an introduction to the special issue.

    PubMed

    Campbell, Richard; Levenstein, Charles

    2015-02-01

    One century ago, the landmark fire at the Triangle Shirtwaist Factory in New York City claimed the lives of 146 garment workers and helped spur the adoption of fire safety measures and laws targeting dangerous working conditions. Since that time, continuing advances have been made to address the threat of fire-in workplace fire safety practices and regulations, in training and safety requirements for firefighters and first responders, and in hazard communication laws that enhance disaster planning and response. Recent high profile events, including the West, Texas fertilizer plant explosion, derailments of fuel cargo trains, and garment factory fires in Bangladesh, have brought renewed attention to fire as a workplace health and safety issue and to the unevenness of safety standards and regulatory enforcement, in the United States as well as internationally. In this article, we provide an overview of fire as a workplace health and safety hazard and an introduction to the essays included in this special issue of New Solutions on fire and work. © 2015 SAGE Publications.

  13. Fire safety: A case study of technology transfer

    NASA Technical Reports Server (NTRS)

    Heins, C. F.

    1975-01-01

    Two basic ways in which NASA-generated technology is being used by the fire safety community are described. First, improved products and systems that embody NASA technical advances are entering the marketplace. Second, NASA test data and technical information related to fire safety are being used by persons concerned with reducing the hazards of fire through improved design information and standards. The development of commercial fire safety products and systems typically requires adaptation and integration of aerospace technologies that may not have been originated for NASA fire safety applications.

  14. Vehicle fires and fire safety in tunnels

    DOT National Transportation Integrated Search

    2002-09-20

    Tunnels present what is arguably the most hazardous environment, from the point of view of fire safety, that members of the public ever experience. The fire safety design of tunnels is carried out by tunnel engineers on the basis of a potential fire ...

  15. Fire! Fire Prevention and Safety: A Teacher's Handbook.

    ERIC Educational Resources Information Center

    New York City Board of Education, Brooklyn, NY. Div. of Educational Planning and Support.

    In this curriculum guide, guidelines for teaching children about fire safety and related topics and activities representing an interdisciplinary approach to fire safety are outlined. Major fire hazards and methods of dealing with them are described. Possible sites for field trips and films relating to fire are listed. The rules of the New York…

  16. Fire Safety Educational Material.

    ERIC Educational Resources Information Center

    Cohn, Bert M.

    The state of the art of home fire safety educational material was reviewed to prepare a bibliography of home fire safety educational materials available from major public and private sources. Sources contacted were: National Fire Protection Association, National Safety Council, U.S. government agencies, private publishers and film distributors,…

  17. Millwright Apprenticeship. Related Training Modules. 1.1-1.8 Safety.

    ERIC Educational Resources Information Center

    Lane Community Coll., Eugene, OR.

    This packet, part of the instructional materials for the Oregon apprenticeship program for millwright training, contains eight modules covering safety. The modules provide information on the following topics: general safety, hand tool safety, power tool safety, fire safety, hygiene, safety and electricity, types of fire and fire prevention, and…

  18. Caught in a tightening fire safety net.

    PubMed

    Baillie, Jonathan

    2008-06-01

    How the Regulatory Reform (Fire Safety) Order 2005 has shifted responsibility for hospital fire safety from local fire authorities to so-called "responsible persons", and the implications for senior management/board-level personnel, as well as for hospital fire officers, fire wardens and department managers charged with implementation, was expertly examined by a leading expert in fire law at May's National Association of Healthcare Fire Officers (NAHFO) 2008 conference in Nottingham. Jonathan Baillie reports.

  19. 75 FR 17641 - Updating Fire Safety Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-07

    ... DEPARTMENT OF VETERANS AFFAIRS 38 CFR Parts 17 and 59 RIN 2900-AN57 Updating Fire Safety Standards... for VA approval of such facilities, including standards for fire safety and heating and cooling... submitted in response to ``RIN 2900-AN57--Updating Fire Safety Standards.'' Copies of comments received will...

  20. 29 CFR 1915.502 - Fire safety plan.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 7 2012-07-01 2012-07-01 false Fire safety plan. 1915.502 Section 1915.502 Labor... Employment § 1915.502 Fire safety plan. (a) Employer responsibilities. The employer must develop and implement a written fire safety plan that covers all the actions that employers and employees must take to...

  1. 29 CFR 1915.502 - Fire safety plan.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 7 2014-07-01 2014-07-01 false Fire safety plan. 1915.502 Section 1915.502 Labor... Employment § 1915.502 Fire safety plan. (a) Employer responsibilities. The employer must develop and implement a written fire safety plan that covers all the actions that employers and employees must take to...

  2. 29 CFR 1915.502 - Fire safety plan.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 7 2013-07-01 2013-07-01 false Fire safety plan. 1915.502 Section 1915.502 Labor... Employment § 1915.502 Fire safety plan. (a) Employer responsibilities. The employer must develop and implement a written fire safety plan that covers all the actions that employers and employees must take to...

  3. Teaching About Fire Safety.

    ERIC Educational Resources Information Center

    Brady, Holly; Arnold, Anne Jurmu

    1982-01-01

    This unit on fire safety teaches students how to act in or during a fire and presents fire prevention measures that students can implement at home. Two reproducible masters concerning fire safety and prevention are presented along with class activities, student reading resources, and organizations and companies that offer classroom materials about…

  4. Teach Children Fire Will Burn.

    ERIC Educational Resources Information Center

    Children's Bureau (DHEW), Washington, DC.

    This handbook, addressed to parents and others responsible for the safety of children, presents information on fire hazards, prevention and protection. Emphasizing an early start to fire safety training, it outlines the basic facts of fire safety education, listing the most frequent causes of fire and suggesting the organization of a Family Fire…

  5. Applications of aerospace technology in industry, a technology transfer profile: Fire safety

    NASA Technical Reports Server (NTRS)

    Kottenstette, J. P.; Freeman, J. E.; Heins, C. R.; Hildred, W. M.; Johnson, F. D.; Staskin, E. R.

    1971-01-01

    The fire safety field is considered as being composed of three parts: an industry, a technology base, and a user base. An overview of the field is presented, including a perspective on the magnitude of the national fire safety problem. Selected NASA contributions to the technology of fire safety are considered. Communication mechanisms, particularly conferences and publications, used by NASA to alert the community to new developments in the fire safety field, are reviewed. Several examples of nonaerospace applications of NASA-generated fire safety technology are also presented. Issues associated with attempts to transfer this technology from the space program to other sectors of the American economy are outlined.

  6. Space station internal environmental and safety concerns

    NASA Technical Reports Server (NTRS)

    Cole, Matthew B.

    1987-01-01

    Space station environmental and safety concerns, especially those involving fires, are discussed. Several types of space station modules and the particular hazards associated with each are briefly surveyed. A brief history of fire detection and suppression aboard spacecraft is given. Microgravity fire behavior, spacecraft fire detector systems, space station fire suppression equipment and procedures, and fire safety in hyperbaric chambers are discussed.

  7. Combustion and fires in low gravity

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1994-01-01

    Fire safety always receives priority attention in NASA mission designs and operations, with emphasis on fire prevention and material acceptance standards. Recently, interest in spacecraft fire-safety research and development has increased because improved understanding of the significant differences between low-gravity and normal-gravity combustion suggests that present fire-safety techniques may be inadequate or, at best, non-optimal; and the complex and permanent orbital operations in Space Station Freedom demand a higher level of safety standards and practices. This presentation outlines current practices and problems in fire prevention and detection for spacecraft, specifically the Space Station Freedom's fire protection. Also addressed are current practices and problems in fire extinguishment for spacecraft.

  8. 42 CFR 403.744 - Condition of participation: Life safety from fire.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 2 2014-10-01 2014-10-01 false Condition of participation: Life safety from fire... safety from fire. (a) General. An RNHCI must meet the following conditions: (1) Except as otherwise... Safety Code of the National Fire Protection Association. The Director of the Office of the Federal...

  9. Development of Large-Scale Spacecraft Fire Safety Experiments

    NASA Technical Reports Server (NTRS)

    Ruff, Gary A.; Urban, David; Fernandez-Pello, A. Carlos; T'ien, James S.; Torero, Jose L.; Legros, Guillaume; Eigenbrod, Christian; Smirnov, Nickolay; Fujita, Osamu; Cowlard, Adam J.; hide

    2013-01-01

    The status is presented of a spacecraft fire safety research project that is under development to reduce the uncertainty and risk in the design of spacecraft fire safety systems by testing at nearly full scale in low-gravity. Future crewed missions are expected to be more complex and longer in duration than previous exploration missions outside of low-earth orbit. This will increase the challenge of ensuring a fire-safe environment for the crew throughout the mission. Based on our fundamental uncertainty of the behavior of fires in low-gravity, the need for realistic scale testing at reduced gravity has been demonstrated. To address this gap in knowledge, a project has been established under the NASA Advanced Exploration Systems Program under the Human Exploration and Operations Mission directorate with the goal of substantially advancing our understanding of the spacecraft fire safety risk. Associated with the project is an international topical team of fire experts from other space agencies who conduct research that is integrated into the overall experiment design. The experiments are under development to be conducted in an Orbital Science Corporation Cygnus vehicle after it has undocked from the ISS. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew removes the need for strict containment of combustion products. The tests will be fully automated with the data downlinked at the conclusion of the test before the Cygnus vehicle reenters the atmosphere. A computer modeling effort will complement the experimental effort. The international topical team is collaborating with the NASA team in the definition of the experiment requirements and performing supporting analysis, experimentation and technology development. The status of the overall experiment and the associated international technology development efforts are summarized.

  10. 30 CFR 75.1103-11 - Tests of fire hydrants and fire hose; record of tests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tests of fire hydrants and fire hose; record of tests. 75.1103-11 Section 75.1103-11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1103-11 Tests of fire hydrants and...

  11. 30 CFR 75.1103-11 - Tests of fire hydrants and fire hose; record of tests.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Tests of fire hydrants and fire hose; record of tests. 75.1103-11 Section 75.1103-11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1103-11 Tests of fire hydrants and...

  12. 30 CFR 75.1103-11 - Tests of fire hydrants and fire hose; record of tests.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Tests of fire hydrants and fire hose; record of tests. 75.1103-11 Section 75.1103-11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1103-11 Tests of fire hydrants and...

  13. 30 CFR 75.1103-11 - Tests of fire hydrants and fire hose; record of tests.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Tests of fire hydrants and fire hose; record of tests. 75.1103-11 Section 75.1103-11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1103-11 Tests of fire hydrants and...

  14. 30 CFR 75.1103-11 - Tests of fire hydrants and fire hose; record of tests.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Tests of fire hydrants and fire hose; record of tests. 75.1103-11 Section 75.1103-11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1103-11 Tests of fire hydrants and...

  15. 36 CFR 910.37 - Fire and life safety.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false Fire and life safety. 910.37... DEVELOPMENT AREA Standards Uniformly Applicable to the Development Area § 910.37 Fire and life safety. As a... recommended that all new development be guided by standards of the NFPA Codes for fire and life safety and...

  16. 36 CFR 910.37 - Fire and life safety.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Fire and life safety. 910.37... DEVELOPMENT AREA Standards Uniformly Applicable to the Development Area § 910.37 Fire and life safety. As a... recommended that all new development be guided by standards of the NFPA Codes for fire and life safety and...

  17. Fire in the Shop!

    ERIC Educational Resources Information Center

    Campbell, Clifton P.; Buchanan, Joseph P.

    1977-01-01

    Fire emergency preparedness measures to take to prevent school fires and to protect against injury and minimize damage when fire does occur are presented. Includes fire safety practices, extinguishers for different classes of fires and their use, and the need for fire safety training in schools. (MF)

  18. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...

  19. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...

  20. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...

  1. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...

  2. Aircraft fire safety research

    NASA Technical Reports Server (NTRS)

    Botteri, Benito P.

    1987-01-01

    During the past 15 years, very significant progress has been made toward enhancing aircraft fire safety in both normal and hostile (combat) operational environments. Most of the major aspects of the aircraft fire safety problem are touched upon here. The technology of aircraft fire protection, although not directly applicable in all cases to spacecraft fire scenarios, nevertheless does provide a solid foundation to build upon. This is particularly true of the extensive research and testing pertaining to aircraft interior fire safety and to onboard inert gas generation systems, both of which are still active areas of investigation.

  3. 49 CFR 238.103 - Fire safety.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Fire safety. 238.103 Section 238.103..., DEPARTMENT OF TRANSPORTATION PASSENGER EQUIPMENT SAFETY STANDARDS Safety Planning and General Requirements § 238.103 Fire safety. (a) Materials. (1) Materials used in constructing a passenger car or a cab of a...

  4. Impact of a community based fire prevention intervention on fire safety knowledge and behavior in elementary school children

    PubMed Central

    Hwang, V; Duchossois, G P; Garcia‐Espana, J F; Durbin, D R

    2006-01-01

    The objective of this study was to determine the impact of a community based fire prevention intervention directed only to parents on the fire safety knowledge and behavior in elementary school children. This was a prospective, quasi‐randomized controlled study in which third and fourth grade students from two elementary schools in an urban, poor, minority community completed knowledge/behavior surveys at baseline and following completion of the intervention. The intervention group received an in‐home visit from fire department personnel who installed free lithium smoke detectors and provided a fire escape plan. After accounting for a small difference in baseline summary scores of knowledge and behavior between the control and intervention groups, this study found a modest improvement in fire safety behavior among children whose families received a fire prevention intervention reflecting a change in household fire safety practices. However, there was no significant change in fire safety knowledge. PMID:17018679

  5. Research Needs in Fire Safety for the Human Exploration and Utilization of Space

    NASA Technical Reports Server (NTRS)

    Ruff, Gary A.

    2003-01-01

    This viewgraph presentation provides information on developments in spacecraft fire safety research. The presentation includes an overview of the previous Spacecraft Fire Safety Workshop, from 1986, and the influences since then of bioastronautics on combustion science and fire safety. The presentation then gives of overview of the current conference, stating goals and giving a schedule.

  6. Acquisition of Fire Safety Knowledge and Skills With Virtual Reality Simulation.

    PubMed

    Rossler, Kelly L; Sankaranarayanan, Ganesh; Duvall, Adrianne

    2018-05-25

    Prelicensure nursing students seeking to enter perioperative nursing need preparatory fire safety knowledge and skills training to participate as a member of an operating room (OR) team. This pilot study examined the effectiveness of the Virtual Electrosurgery Skill Trainer (VEST) on OR fire safety skills among prelicensure nursing students. An experimental pretest-posttest design was used in this study. Twenty nursing students were randomized to a control or an intervention group. Knowledge and skills acquisition of OR fire safety were assessed. There were no statistically significant findings in knowledge for either group. Fisher exact test demonstrated significant relationships between the skills performance criteria of following emergency procedures for a fire and demonstrating PASS (pull-aim-squeeze-sweep) technique (P = .001). Academic and hospital educators may consider incorporating virtual reality simulation to teach fire safety education or reinforce general fire safety practices to nursing students and novice nurses.

  7. Occupational burns from oxygen resuscitator fires: the hazard of aluminum regulators.

    PubMed

    Hodous, Thomas K; Washenitz, Frank; Newton, Barry

    2002-07-01

    There have been over 30 incidents of oxygen resuscitator fires over the last 6 years, causing severe burns to a number of fire fighters, emergency medical service personnel, health care workers, and patients. The National Institute for Occupational Safety and Health (NIOSH) was requested to investigate three such incidents. NIOSH conducted site investigations of the incidents, and the requesters also sent the involved oxygen resuscitators to a forensic engineering company for a causal analysis. The investigated fires were associated with aluminum regulators, all from one manufacturer, on compressed pure oxygen cylinders. The investigations indicated that the cause of the fires was an initial small ignition in the high-pressure area of the aluminum regulator, which then consumed itself in a massive burnout. Aluminum regulators used with high-pressure oxygen systems are subject to rare, but potentially catastrophic combustion in normal use. Replacement of such regulators with those made of more fire-resistant materials or designs, as well as education and improved safety practices are needed to reduce this hazard.

  8. 41 CFR 102-80.110 - What must an equivalent level of safety analysis indicate?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What must an equivalent... Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Accident and Fire Prevention Equivalent Level of Safety...

  9. Summaries of BFRL fire research in-house projects and grants, 1993

    NASA Astrophysics Data System (ADS)

    Jason, Nora H.

    1993-09-01

    The report describes the fire research projects performed in the Building and Fire Research Laboratory (BFRL) and under its extramural grants program during fiscal year 1993. The BFRL Fire Research Program has directed its efforts under three program thrusts. The in-house priority projects, grants, and externally-funded efforts thus form an integrated, focussed ensemble. The publication is organized along those lines: fire risk and hazard prediction - carbon monoxide prediction, turbulent combustion, soot, engineering analysis, fire hazard assessment, and large fires; fire safety of products and materials - materials combustion, furniture flammability, and wall and ceiling fires; and advanced technologies for fire sensing and control - fire detection and fire suppression. For the convenience of the reader, an alphabetical listing of all grants is contained in Part 2.0.

  10. Help Children--and Families--Learn Basic Fire Safety.

    ERIC Educational Resources Information Center

    Texas Child Care, 2001

    2001-01-01

    Presents tips to help early childhood teachers and caregivers teach young children fire safety. Provides checklist for preventing fires in the kitchen, classrooms, and storage areas. Offers suggestions for classroom learning activities and for educating families about fire safety. Includes annotated bibliography of children's books dealing with…

  11. 76 FR 70885 - Updating Fire Safety Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-16

    ... DEPARTMENT OF VETERANS AFFAIRS 38 CFR Part 59 RIN 2900-AN57 Updating Fire Safety Standards AGENCY... Fire Protection Association (NFPA) 101. This rule helps ensure the safety of veterans in the affected... publications are: NFPA 10, Standard for Portable Fire Extinguishers; NFPA 99, Standard for Health Care...

  12. Safety survey report EBR-II safety survey, ANL-west health protection, industrial safety and fire protection survey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dunbar, K.A.

    1972-01-10

    A safety survey covering the disciplines of Reactor Safety, Nuclear Criticality Safety, Health Protection and Industrial Safety and Fire Protection was conducted at the ANL-West EBR-II FEF Complex during the period January 10-18, 1972. In addition, the entire ANL-West site was surveyed for Health Protection and Industrial Safety and Fire Protection. The survey was conducted by members of the AEC Chicago Operations Office, a member of RDT-HQ and a member of the RDT-ID site office. Eighteen recommendations resulted from the survey, eleven in the area of Industrial Safety and Fire Protection, five in the area of Reactor Safety and twomore » in the area of Nuclear Criticality Safety.« less

  13. 24 CFR 232.620 - Determination of compliance by HHS.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... of Fire Safety Equipment Special Requirements § 232.620 Determination of compliance by HHS. An... the fire safety equipment has been installed, will be in compliance with the HHS requirements for fire... Security Act upon the installation of the fire safety equipment. The architectural exhibits, as approved...

  14. 46 CFR 62.35-15 - Fire safety.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Fire safety. 62.35-15 Section 62.35-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Requirements for Specific Types of Automated Vital Systems § 62.35-15 Fire safety. (a) All required fire pump...

  15. 78 FR 17140 - Upholstered Furniture Fire Safety Technology; Meeting and Request for Comments

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-20

    ... Furniture Fire Safety Technology; Meeting and Request for Comments AGENCY: Consumer Product Safety... Commission (CPSC, Commission, or we) is announcing its intent to hold a meeting on upholstered furniture fire... http://www.cpsc.gov/meetingsignup.html and click on the link titled, ``Upholstered Furniture Fire...

  16. 46 CFR 62.35-15 - Fire safety.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Fire safety. 62.35-15 Section 62.35-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Requirements for Specific Types of Automated Vital Systems § 62.35-15 Fire safety. (a) All required fire pump...

  17. 30 CFR 75.1107-16 - Inspection of fire suppression devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-16 Section 75.1107-16 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire... Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA...

  18. 30 CFR 75.1107-16 - Inspection of fire suppression devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-16 Section 75.1107-16 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire... Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA...

  19. 48 CFR 2052.235-71 - Safety, health, and fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....235-71 Safety, health, and fire protection. As prescribed in 2035.70(a)(2), the contracting officer... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Safety, health, and fire..., Health, and Fire Protection (JAN 1993) The contractor shall take all reasonable precautions in the...

  20. 48 CFR 2052.235-71 - Safety, health, and fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....235-71 Safety, health, and fire protection. As prescribed in 2035.70(a)(2), the contracting officer... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Safety, health, and fire..., Health, and Fire Protection (JAN 1993) The contractor shall take all reasonable precautions in the...

  1. 48 CFR 2052.235-71 - Safety, health, and fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....235-71 Safety, health, and fire protection. As prescribed in 2035.70(a)(2), the contracting officer... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false Safety, health, and fire..., Health, and Fire Protection (JAN 1993) The contractor shall take all reasonable precautions in the...

  2. 48 CFR 2052.235-71 - Safety, health, and fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....235-71 Safety, health, and fire protection. As prescribed in 2035.70(a)(2), the contracting officer... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Safety, health, and fire..., Health, and Fire Protection (JAN 1993) The contractor shall take all reasonable precautions in the...

  3. An organizational process for promoting home fire safety in two community settings.

    PubMed

    Lehna, Carlee; Twyman, Stephanie; Fahey, Erin; Coty, Mary-Beth; Williams, Joe; Scrivener, Drane; Wishnia, Gracie; Myers, John

    2017-02-01

    The purpose of this study was to describe the home fire safety quality improvement model designed to aid organizations in achieving institutional program goals. The home fire safety model was developed from community-based participatory research (CBPR) applying training-the-trainer methods and is illustrated by an institutional case study. The model is applicable to other types of organizations to improve home fire safety in vulnerable populations. Utilizing the education model leaves trained employees with guided experience to build upon, adapt, and modify the home fire safety intervention to more effectively serve their clientele, promote safety, and meet organizational objectives. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  4. [Considering the current state of fire safety in Taiwan's care environment from the perspective of the nation's worst recent hospital fire].

    PubMed

    Tseng, Wei-Wen; Shih, Chung-Liang; Chien, Shen-Wen

    2013-04-01

    Taiwan's worst hospital fire in history on October 23rd, 2012 at Sinying Hospital's Bei-Men Branch resulted in 13 elderly patient deaths and over 70 injuries. The heavy casualties were due in part to the serious condition of patients. Some patients on life-support machines were unable to move or be moved. This disaster highlights the issue of fire safety in small-scale hospitals that have transformed existing hospital space into special care environments for elderly patients. Compared with medical centers and general hospitals, these small-scale health facilities are ill equipped to deal properly with fire safety management and emergency response issues due to inadequate fire protection facilities, fire safety equipment, and human resources. Small-scale facilities that offer health care and medical services to mostly immobile patients face fire risks that differ significantly from general health care facilities. This paper focuses on fire risks in small-scale facilities and suggests a strategy for fire prevention and emergency response procedures, including countermeasures for fire risk assessment, management, and emergency response, in order to improve fire safety at these institutions in Taiwan.

  5. Fire safety concerns in space operations

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1987-01-01

    This paper reviews the state-of-the-art in fire control techniques and identifies important issues for continuing research, technology, and standards. For the future permanent orbiting facility, the space station, fire prevention and control calls for not only more stringent fire safety due to the long-term and complex missions, but also for simplified and flexible safety rules to accommodate the variety of users. Future research must address a better understanding of the microgravity space environment as it influences fire propagation and extinction and the application of the technology of fire detection, extinguishment, and material assessment. Spacecraft fire safety should also consider the adaptation of methods and concepts derived from aircraft and undersea experience.

  6. 29 CFR 1915.502 - Fire safety plan.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 7 2011-07-01 2011-07-01 false Fire safety plan. 1915.502 Section 1915.502 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard...

  7. 29 CFR 1915.502 - Fire safety plan.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Fire safety plan. 1915.502 Section 1915.502 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard...

  8. Charged Up for Fire Safety. Fifth Grade. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the fifth grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of fifth grade students, its objectives include: (1) exploring heating equipment safety, (2) analyzing the impact of fire on the outdoor environment and methods to reduce that impact, (3) developing…

  9. Fire safety applications for spacecraft

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Olson, Sandra L.

    1989-01-01

    Fire safety for spacecraft is reviewed by first describing current practices, many of which are adapted directly from aircraft. Then, current analyses and experimental knowledge in low-gravity combustion, with implications for fire safety are discussed. In orbiting spacecraft, the detection and suppression of flames are strongly affected by the large reduction in buoyant flows under low gravity. Generally, combustion intensity is reduced in low gravity. There are some notable exceptions, however, one example being the strong enhancement of flames by low-velocity ventilation flows in space. Finally, the future requirements in fire safety, particularly the needs of long-duration space stations in fire prevention, detection, extinguishment, and atmospheric control are examined. The goal of spacecraft fire-safety investigations is the establishment of trade-offs that promote maximum safety without hampering the useful human and scientific activities in space.

  10. An evaluation of The Great Escape: can an interactive computer game improve young children's fire safety knowledge and behaviors?

    PubMed

    Morrongiello, Barbara A; Schwebel, David C; Bell, Melissa; Stewart, Julia; Davis, Aaron L

    2012-07-01

    Fire is a leading cause of unintentional injury and, although young children are at particularly increased risk, there are very few evidence-based resources available to teach them fire safety knowledge and behaviors. Using a pre-post randomized design, the current study evaluated the effectiveness of a computer game (The Great Escape) for teaching fire safety information to young children (3.5-6 years). Using behavioral enactment procedures, children's knowledge and behaviors related to fire safety were compared to a control group of children before and after receiving the intervention. The results indicated significant improvements in knowledge and fire safety behaviors in the intervention group but not the control. Using computer games can be an effective way to promote young children's understanding of safety and how to react in different hazardous situations.

  11. The analysis of factors of management of safety of critical information infrastructure with use of dynamic models

    NASA Astrophysics Data System (ADS)

    Trostyansky, S. N.; Kalach, A. V.; Lavlinsky, V. V.; Lankin, O. V.

    2018-03-01

    Based on the analysis of the dynamic model of panel data by region, including fire statistics for surveillance sites and statistics of a set of regional socio-economic indicators, as well as the time of rapid response of the state fire service to fires, the probability of fires in the surveillance sites and the risk of human death in The result of such fires from the values of the corresponding indicators for the previous year, a set of regional social-economics factors, as well as regional indicators time rapid response of the state fire service in the fire. The results obtained are consistent with the results of the application to the fire risks of the model of a rational offender. Estimation of the economic equivalent of human life from data on surveillance objects for Russia, calculated on the basis of the analysis of the presented dynamic model of fire risks, correctly agrees with the known literary data. The results obtained on the basis of the econometric approach to fire risks allow us to forecast fire risks at the supervisory sites in the regions of Russia and to develop management solutions to minimize such risks.

  12. Fire Safety Training Handbook.

    ERIC Educational Resources Information Center

    Montgomery County Dept. of Fire and Rescue Services, Rockville, MD. Div. of Fire Prevention.

    Designed for a community fire education effort, particularly in which local volunteers present general information on fire safety to their fellow citizens, this workbook contains nine lessons. Included are an overview of the household fire problem; instruction in basic chemistry and physics of fire, flammable liquids, portable fire extinguishers,…

  13. Revised fire safety system cuts emergency response time.

    PubMed

    Keir, D C

    1979-03-01

    As Margaret R. Pardee Memorial Hospital, Hendersonville, NC. expanded, fire safety plans had to be reevaluated. With each new addition, fire safety responsibilities for hospital personnel multiplied and overlapped. Confusion resulted, and a revised, simplified, and coordinated fire safety system was devised. Seventeen false alarms within one year, caused by a faulty sprinkler system, gave hospital personnel ample opportunity to test the system and iron out unexpected problems.

  14. Safety issues of high-concentrated hydrogen peroxide production used as rocket propellant

    NASA Astrophysics Data System (ADS)

    Romantsova, O. V.; Ulybin, V. B.

    2015-04-01

    The article dwells on the possibility of production of high-concentrated hydrogen peroxide with the Russian technology of isopropyl alcohol autoxidation. Analysis of fire/explosion hazards and reasons of insufficient quality is conducted for the technology. Modified technology is shown. Non-standard fire/explosion characteristics required for integrated fire/explosion hazards rating for modified hydrogen peroxide production based on the autoxidation of isopropyl alcohol are defined.

  15. 36 CFR § 910.37 - Fire and life safety.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... for fire and life safety and that all buildings be equipped with an approved sprinkler system. ... 36 Parks, Forests, and Public Property 3 2013-07-01 2012-07-01 true Fire and life safety. § 910... PENNSYLVANIA AVENUE DEVELOPMENT AREA Standards Uniformly Applicable to the Development Area § 910.37 Fire and...

  16. Special report. Revising your fire safety plans.

    PubMed

    1993-12-01

    Every hospital has a fire safety plan, although some fail to update their plans when circumstances change, such as when the facility is refurbished or new fire protection equipment is added, or when new wings bring in additional patients and staff. Others may fail to develop new education programs to heighten staff awareness of what is expected of them during a fire and to train employees to meet those expectations. In this report, we'll examine the new fire safety plans at two Massachusetts hospitals and the revisions they made to address these issues. We'll offer suggestions for effectively evaluating and revising your own fire safety plans.

  17. Where's the Fire?

    ERIC Educational Resources Information Center

    Needham, Dorothy

    1977-01-01

    National Fire Protection Week is a perfect time for launching a fire safety learning center. The activities described here are intended to help children recognize fire hazards in their homes, play areas and public buildings; learn how to act intelligently in fire emergencies; be able to share their knowledge of fire safety with others and…

  18. Surgical fires: a patient safety perspective.

    PubMed

    2006-02-01

    A surgical fire is a fire that occurs on or in a surgical patient. Such fires are rare--they occur in only an extremely small percentage of surgical cases. Nevertheless, the actual number of incidents that occur each year may surprise many healthcare professionals. ECRI estimates that 50 to 100 or more surgical fires occur each year in the United States alone. And such fires can have devastating consequences, not only for the patient, but also for the surgical staff and for the healthcare facility. Fortunately, through awareness of the hazards-and with emphasis placed on following safe practices-virtually all surgical fires can be prevented. Thus, it's important that surgical fire safety be incorporated into formal patient safety initiatives. In this article, we describe a few surgical fire patient safety initiatives that have been instituted in recent years. In addition, we describe in detail the causes of surgical fires and the preventive measures that are available for healthcare personnel to follow. In addition, we review how staff should respond in the event of a surgical fire.

  19. Program for developing and implementing a new approach to designing for fire safety in buildings

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The traditional method of providing for fire safety in buildings through reliance on codes and standards that prescribe specific measures to be taken in the design and construction of buildings to minimize the potential for a fire occurring and to protect property and life should a fire occur was evaluated. A new approach to designing for fire safety in buildings is outlined.

  20. Science and technology issues in spacecraft fire safety

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Sacksteder, Kurt R.

    1987-01-01

    The space station, a permanently-inhabited orbiting laboratory, places new demands on spacecraft fire safety. Long-duration missions may call for more-constrained fire controls, but the accessibility of the space station to a variety of users may call for less-restrictive measures. This paper discusses fire safety issues through a review of the state of the art and a presentation of key findings from a recent NASA Lewis Research Center Workshop. The subjects covered are the fundamental science of low-gravity combustion and the technology advances in fire detection, extinguishment, materials assessment, and atmosphere selection. Key concerns are for the adoption of a fire-safe atmosphere and the substitution for the effective but toxic extinguishant, halon 1301. The fire safety studies and reviews provide several recommendations for further action. One is the expanded research in combustion, sensors, and materials in the low-gravity environment of space. Another is the development of generalized fire-safety standards for spacecraft through cooperative endeavors with aerospace and outside Government and industry sources.

  1. 29 CFR Appendix D to Subpart L of... - Availability of Publications Incorporated by Reference in Section 1910.156 Fire Brigades

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Criteria for Structural Firefighter's Helmets” (1977) U.S. Fire Administration, National Fire Safety and... Section 1910.156 Fire Brigades D Appendix D to Subpart L of Part 1910 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH...

  2. Measuring behaviours for escaping from house fires: use of latent variable models to summarise multiple behaviours.

    PubMed

    Ploubidis, G B; Edwards, P; Kendrick, D

    2015-12-15

    This paper reports the development and testing of a construct measuring parental fire safety behaviours for planning escape from a house fire. Latent variable modelling of data on parental-reported fire safety behaviours and plans for escaping from a house fire and multivariable logistic regression to quantify the association between groups defined by the latent variable modelling and parental-report of having a plan for escaping from a house fire. Data comes from 1112 participants in a cluster randomised controlled trial set in children's centres in 4 study centres in the UK. A two class model provided the best fit to the data, combining responses to five fire safety planning behaviours. The first group ('more behaviours for escaping from a house fire') comprised 86% of participants who were most likely to have a torch, be aware of how their smoke alarm sounds, to have external door and window keys accessible, and exits clear. The second group ('fewer behaviours for escaping from a house fire') comprised 14% of participants who were less likely to report these five behaviours. After adjusting for potential confounders, participants allocated to the 'more behaviours for escaping from a house fire group were 2.5 times more likely to report having an escape plan (OR 2.48; 95% CI 1.59-3.86) than those in the "fewer behaviours for escaping from a house fire" group. Multiple fire safety behaviour questions can be combined into a single binary summary measure of fire safety behaviours for escaping from a house fire. Our findings will be useful to future studies wishing to use a single measure of fire safety planning behaviour as measures of outcome or exposure. NCT 01452191. Date of registration 13/10/2011.

  3. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 3 2010-07-01 2010-07-01 false Institutional fire safety policies and fire statistics... fire statistics. (a) Additional definitions that apply to this section. Cause of fire: The factor or... statistics described in paragraph (c) of this section. (2) A description of each on-campus student housing...

  4. 24 CFR 3280.201 - Scope.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.201 Scope. The purpose of this subpart is to set forth requirements that will assure reasonable fire safety to the occupants by reducing fire hazards and by providing measures for early detection. ...

  5. 24 CFR 3280.201 - Scope.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.201 Scope. The purpose of this subpart is to set forth requirements that will assure reasonable fire safety to the occupants by reducing fire hazards and by providing measures for early detection. ...

  6. 24 CFR 3280.201 - Scope.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.201 Scope. The purpose of this subpart is to set forth requirements that will assure reasonable fire safety to the occupants by reducing fire hazards and by providing measures for early detection. ...

  7. 24 CFR 3280.201 - Scope.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.201 Scope. The purpose of this subpart is to set forth requirements that will assure reasonable fire safety to the occupants by reducing fire hazards and by providing measures for early detection. ...

  8. 24 CFR 3280.201 - Scope.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.201 Scope. The purpose of this subpart is to set forth requirements that will assure reasonable fire safety to the occupants by reducing fire hazards and by providing measures for early detection. ...

  9. 29 CFR 1915.501 - General provisions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard... require employers to protect all employees from fire hazards in shipyard employment, including employees...

  10. 29 CFR 1915.501 - General provisions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard... require employers to protect all employees from fire hazards in shipyard employment, including employees...

  11. 29 CFR 1915.501 - General provisions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard... require employers to protect all employees from fire hazards in shipyard employment, including employees...

  12. 41 CFR 102-80.120 - What analytical and empirical tools should be used to support the life safety equivalency...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) FEDERAL MANAGEMENT REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Accident and Fire... used to support the life safety equivalency evaluation? Analytical and empirical tools, including fire models and grading schedules such as the Fire Safety Evaluation System (Alternative Approaches to Life...

  13. 41 CFR 102-80.120 - What analytical and empirical tools should be used to support the life safety equivalency...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) FEDERAL MANAGEMENT REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Accident and Fire... used to support the life safety equivalency evaluation? Analytical and empirical tools, including fire models and grading schedules such as the Fire Safety Evaluation System (Alternative Approaches to Life...

  14. 41 CFR 102-80.120 - What analytical and empirical tools should be used to support the life safety equivalency...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) FEDERAL MANAGEMENT REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Accident and Fire... used to support the life safety equivalency evaluation? Analytical and empirical tools, including fire models and grading schedules such as the Fire Safety Evaluation System (Alternative Approaches to Life...

  15. Commonalities in Transportation Fire Safety : Regulations, Research and Development, and Data Bases

    DOT National Transportation Integrated Search

    1980-01-01

    This report presents a comprehensive review of current modal fire safety efforts within the U.S. Department of Transportation. Common fire safety problems and modal administration response are identified. Work completed includes a review of modal adm...

  16. 24 CFR 3280.209 - Fire testing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Fire testing. 3280.209 Section 3280... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.209 Fire testing. All fire testing conducted in accordance with this subpart shall be performed by nationally recognized testing...

  17. 24 CFR 3280.209 - Fire testing.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Fire testing. 3280.209 Section 3280... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.209 Fire testing. All fire testing conducted in accordance with this subpart shall be performed by nationally recognized testing...

  18. 24 CFR 3280.209 - Fire testing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Fire testing. 3280.209 Section 3280... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.209 Fire testing. All fire testing conducted in accordance with this subpart shall be performed by nationally recognized testing...

  19. 24 CFR 3280.209 - Fire testing.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Fire testing. 3280.209 Section 3280... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.209 Fire testing. All fire testing conducted in accordance with this subpart shall be performed by nationally recognized testing...

  20. Fire safety of ground-based space facilities on the spaceport ;Vostochny;

    NASA Astrophysics Data System (ADS)

    Artamonov, Vladimir S.; Gordienko, Denis M.; Melikhov, Anatoly S.

    2017-06-01

    The facilities of the spaceport ;Vostochny; and the innovative technologies for fire safety to be implemented are considered. The planned approaches and prospects for fire safety ensuring at the facilities of the spaceport ;Vostochny; are presented herein, based on the study of emergency situations having resulted in fire accidents and explosion cases at the facilities supporting space vehicles operation.

  1. 76 FR 3178 - Fire Protection in Shipyard Employment Standard; Extension of the Office of Management and Budget...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-19

    ... (paperwork) requirements. In general, the Standard requires employers to develop a written fire safety plan... of the details of the fire safety plan and that employees have been trained as required by the... to post the fire safety plan or to place it in an area accessible to employees to 12 hours for firms...

  2. Fire Safety: Stop the Heat. Fourth Grade. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the fourth grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of fourth grade students, its objectives include: (1) understanding principles of extinguishing fires, (2) investigating issues of peer pressure related to fire setting, (3) developing…

  3. Medical Oxygen Safety

    MedlinePlus

    ... to the air a patient uses to breathe. Fire needs oxygen to burn. If a fire should start in an oxygen-enriched area, the ... Homes where medical oxygen is used need specific fire safety rules to keep people safe from fire ...

  4. Risks, designs, and research for fire safety in spacecraft

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Sacksteder, Kurt R.; Urban, David

    1991-01-01

    Current fire protection for spacecraft relies mainly on fire prevention through the use of nonflammable materials and strict storage controls of other materials. The Shuttle also has smoke detectors and fire extinguishers, using technology similar to aircraft practices. While experience has shown that the current fire protection is adequate, future improvements in fire safety technology to meet the challenges of long duration space missions, such as the Space Station Freedom, are essential. All spacecraft fire protection systems, however, must deal with the unusual combustion characteristics and operational problems in the low gravity environment. The features of low gravity combustion that affect spacecraft fire safety, and the issues in fire protection for Freedom that must be addressed eventually to provide effective and conservative fire protection systems are discussed.

  5. A composite system approach to aircraft cabin fire safety

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Parker, J. A.; Gilwee, W. J., Jr.; Lerner, N. R.; Hilado, C. J.; Labossiere, L. A.; Hsu, M.-T.

    1976-01-01

    The thermochemical and flammability characteristics of two polymeric composites currently in use and seven others being considered for use as aircraft interior panels are described. The properties studied included: (1) limiting oxygen index of the composite constituents; (2) fire containment capability of the composite; (3) smoke evolution from the composite; (4) thermogravimetric analysis; (5) composition of the volatile products of thermal degradation; and (6) relative toxicity of the volatile products of pyrolysis. The performance of high-temperature laminating resins such as bismaleimides is compared with the performance of phenolics and epoxies. The relationship of increased fire safety with the use of polymers with high anaerobic char yield is shown. Processing parameters of one of the bismaleimide composites is detailed.

  6. A composite system approach to aircraft cabin fire safety

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Parker, J. A.; Gilwee, W. J., Jr.; Lerner, N. R.; Hilado, C. J.; Labossiere, L. A.; Hsu, M. T. S.

    1976-01-01

    The thermochemical and flammability characteristics of two polymeric composites currently in use and seven others being considered for use as aircraft interior panels are described. The properties studied included: (1) limiting oxygen index of the composite constituents; (2) fire containment capability of the composite; (3) smoke evolution from the composite; (4) thermogravimetric analysis; (5) composition of the volatile products of thermal degradation; and (6) relative toxicity of the volatile products of pyrolysis. The performance of high temperature laminating resins such as bismaleimides is compared with the performance of phenolics and epoxies. The relationship of increased fire safety with the use of polymers with high anaerobic char yield is shown. Processing parameters of one of the baremaleimide composites are detailed.

  7. Materials research for aircraft fire safety

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Parker, J. A.; Bricker, R. W.

    1976-01-01

    The thermochemical and flammability characteristics of two polymeric composites currently in use and seven others being considered for use as aircraft interior panels are described. The properties studied included: (1) limiting oxygen index of the composite constituents; (2) fire containment capability of the composite; (3) smoke evolution from the composite; (4) thermogravimetric analysis; (5) composition of the volatile products of thermal degradation; and (6) relative toxicity of the volatile products of pyrolysis. The performance of high-temperature laminating resins such as bismaleimides is compared with the performance of phenolics and epoxies. The relationship of increased fire safety with the use of polymers with high anaerobic char yield is shown. Processing parameters of the state-of-the-art and the advanced bismaleimide composites are detailed.

  8. Unmanned Vehicle Material Flammability Test

    NASA Technical Reports Server (NTRS)

    Urban, David L.; Ruff, Gary A.; Minster, Olivier; Toth, Balazs; Fernandez-Pello, A. Carlos; Tien, James S.; Torero, Jose L.; Cowlard, Adam J.; Legros, Guillaume; Eigenbrod, Christian; hide

    2012-01-01

    Microgravity fire behaviour remains poorly understood and a significant risk for spaceflight An experiment is under development that will provide the first real opportunity to examine this issue focussing on two objectives: a) Flame Spread. b) Material Flammability. This experiment has been shown to be feasible on both ESA's ATV and Orbital Science's Cygnus vehicles with the Cygnus as the current base-line carrier. An international topical team has been formed to develop concepts for that experiment and support its implementation: a) Pressure Rise prediction. b) Sample Material Selection. This experiment would be a landmark for spacecraft fire safety with the data and subsequent analysis providing much needed verification of spacecraft fire safety protocols for the crews of future exploration vehicles and habitats.

  9. 48 CFR 245.7311-2 - Safety, security, and fire regulations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Safety, security, and fire regulations. 245.7311-2 Section 245.7311-2 Federal Acquisition Regulations System DEFENSE ACQUISITION... Inventory 245.7311-2 Safety, security, and fire regulations. ...

  10. 30 CFR 57.4560 - Mine entrances.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control... escapeways shall be— (a) Provided with a fire suppression system, other than fire extinguishers and water...

  11. 30 CFR 75.1107-13 - Approval of other fire suppression devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-13 Approval of... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approval of other fire suppression devices. 75...

  12. Fire Safety for Retired Adults: Participant's Coursebook.

    ERIC Educational Resources Information Center

    Walker (Bonnie) and Associates, Inc., Crofton, MD.

    The risk of dying from fire increases substantially among older adults. This document contains a collection of fire safety information for elderly people. Information includes procedures to follow in case of fire and early warning technologies such as smoke alarms. The booklet describes potential sources of fires (smoking, home heating, kitchens,…

  13. 24 CFR 3280.209 - Fire testing.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Fire testing. 3280.209 Section 3280... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.209 Fire testing. Link to an amendment published at 78 FR 73982, Dec. 9, 2013. All fire testing conducted in accordance with...

  14. Fire Safety. Managing School Facilities, Guide 6.

    ERIC Educational Resources Information Center

    Department for Education and Employment, London (England). Architects and Building Branch.

    This booklet discusses how United Kingdom schools can manage fire safety and minimize the risk of fire. The guide examines what legislation school buildings must comply with and covers the major risks. It also describes training and evacuation procedures and provides guidance on fire precautions, alarm systems, fire fighting equipment, and escape…

  15. Current State of European Railway Fire Safety Research

    DOT National Transportation Integrated Search

    1985-06-01

    This report describes the recent fire safety research and practical fire experience of the major European railways. It includes a summary of the main causes and characteristics of railway vehicle fires, general approaches to the problem, and existing...

  16. 33 CFR 165.152 - Coast Guard Station Fire Island, Long Island, New York-safety zone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... § 165.152 Coast Guard Station Fire Island, Long Island, New York—safety zone. (a) Location. The following waters of Fire Island Inlet are a safety zone: Beginning at a point on shore at 40°37.523′ N, 073... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Coast Guard Station Fire Island...

  17. Children's Knowledge of Fire Safety: A Report for the New Zealand Fire Service.

    ERIC Educational Resources Information Center

    Constable, Cheryl; Renwick, Margery

    The study reported in this document was conducted to measure the impact of the New Zealand Fire Service's new fire safety program on elementary school students. Firefighters in each fire station and voluntary fire brigade in New Zealand were responsible for arranging a visit to every elementary school within their area to present a learning…

  18. Fire Safety's My Job. Eighth Grade. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the eighth grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of eighth grade students, its objectives include: (1) focusing on technical aspects of fire hazards and detection, and (2) exploring fire hazards outside the home. Texas essential elements of…

  19. Responsible for Fire Safety. Seventh Grade. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the seventh grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of seventh grade students, its objectives include: (1) practicing responsible decision-making regarding fire and burn hazards, including peer pressure related to fire risks; and (2) practicing…

  20. Fire Safety Analysis of the Polar Icebreaker Replacement Design. Volume 2

    DTIC Science & Technology

    1987-10-01

    report. ; iote : At t tne -3f incident only five or sx men were aboard: therefore, they could not atterrot to attack a fire of this intensmtp t hemse I...fire extinguisher (PKP) AUTOMATIC: A1301 Halon 1301 total flooding system - remotely actuated AF AFFF (3%) sprinkler system - remotely actuated AFM...simulate wind effects, we have found that its judicious use along with the vent and shaft routines allows for the modelling of simple HVAC systems

  1. First Aid: Burns

    MedlinePlus

    ... for: Parents Kids Teens Kitchen: Household Safety Checklist Fireworks Safety First Aid: Sunburn Firesetting Fire Safety Burns ... Being Safe in the Kitchen Finding Out About Fireworks Safety Playing With Fire? Dealing With Burns Fireworks ...

  2. Directory of workers in the fire field

    NASA Technical Reports Server (NTRS)

    Kuvshinoff, B. W.; Mcleod, S. B.; Katz, R. G.

    1973-01-01

    A directory was compiled to provide a list of workers engaged in fire research, their addresses and affiliations, and their principal fields of activity. The initial criteria for the selection of names for the directory are recent contributions to fire literature, teaching of subjects relevant to fire science, or participation in or support of fire research programs. With some exceptions, fire service personnel and fire protection engineers were excluded because directories already exist for these professionals. Also excluded are investigators engaged principally in studies of propulsion, combustion, and explosion phenomena, because these areas of study are somewhat aside from the main focus of fire research. For purposes of the directory, fire science is taken to be the body of knowledge, art, and skill related to the investigation, analysis, and interpretation of the phenomena of unwanted fires and the evaluation of materials methods, systems, and equipment related to fire safety, prevention, detection, and suppression.

  3. Fire Safety in Nursing Facilities: Participant's Coursebook.

    ERIC Educational Resources Information Center

    Walker (Bonnie) and Associates, Inc., Crofton, MD.

    Fewer people die in nursing facility fires than in fires occurring in other places where older people live. Fire remains, however, a significant threat in nursing facilities. This book is centered around six "modules" that present a fire safety training program for managers and staff in nursing homes. These modules present the following…

  4. 30 CFR 57.4202 - Fire hydrants.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fire hydrants. 57.4202 Section 57.4202 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control...

  5. 30 CFR 56.4202 - Fire hydrants.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fire hydrants. 56.4202 Section 56.4202 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control...

  6. 30 CFR 57.4230 - Surface self-propelled equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 57.4230 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire... fire or its effects could impede escape from self-propelled equipment, a fire extinguisher shall be on...

  7. Plutonium Oxide Containment and the Potential for Water-Borne Transport as a Consequence of ARIES Oxide Processing Operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wayne, David Matthew; Rowland, Joel C.

    2015-02-01

    The question of oxide containment during processing and storage has become a primary concern when considering the continued operability of the Plutonium Facility (PF-4) at Los Alamos National Laboratory (LANL). An Evaluation of the Safety of the Situation (ESS), “Potential for Criticality in a Glovebox Due to a Fire” (TA55-ESS-14-002-R2, since revised to R3) first issued in May, 2014 summarizes these concerns: “The safety issue of fire water potentially entering a glovebox is: the potential for the water to accumulate in the bottom of a glovebox and result in an inadvertent criticality due to the presence of fissionable materials inmore » the glovebox locations and the increased reflection and moderation of neutrons from the fire water accumulation.” As a result, the existing documented safety analysis (DSA) was judged inadequate and, while it explicitly considered the potential for criticality resulting from water intrusion into gloveboxes, criticality safety evaluation documents (CSEDs) for the affected locations did not evaluate the potential for fire water intrusion into a glovebox.« less

  8. 77 FR 4897 - Safety Zone; M/V Del Monte Live-Fire Gun Exercise, James River, Isle of Wight, VA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-01

    ...-AA00 Safety Zone; M/V Del Monte Live-Fire Gun Exercise, James River, Isle of Wight, VA AGENCY: Coast... provide for the safety of life on navigable waters during the live-fire gun exercises on the M/V Del Monte... associated with the live-fire gun exercise. DATES: This rule is effective in the CFR on February 1, 2012...

  9. 76 FR 31848 - Safety Zone; M/V Del Monte Live-Fire Gun Exercise, James River, Isle of Wight, Virginia

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-02

    ...-AA00 Safety Zone; M/V Del Monte Live-Fire Gun Exercise, James River, Isle of Wight, Virginia AGENCY... provide for the safety of life on navigable waters during the live-fire gun exercises on the M/V Del Monte... associated with the live-fire gun exercise. DATES: This rule will be effective from 11 a.m. June 6, 2011...

  10. Bibliography on aircraft fire hazards and safety. Volume 2: Safety. Part 1: Key numbers 1 to 524

    NASA Technical Reports Server (NTRS)

    Pelouch, J. J., Jr. (Compiler); Hacker, P. T. (Compiler)

    1974-01-01

    Bibliographic citations are presented to describe and define aircraft safety methods, equipment, and criteria. Some of the subjects discussed are: (1) fire and explosion suppression using whiffle balls, (2) ultraviolet flame detecting sensors, (3) evaluation of flame arrestor materials for aircraft fuel systems, (4) crash fire prevention system for supersonic commercial aircraft, and (5) fire suppression for aerospace vehicles.

  11. What's Your Fire Safety IQ?

    ERIC Educational Resources Information Center

    PTA Today, 1992

    1992-01-01

    The National Fire Protection Association offers a quiz on fire safety designed to help people learn about the major fire dangers and change the way they respond to them. Recommends that families sit down and take the quiz together, focusing on the correct answers provided. (SM)

  12. Fire Won't Wait--Plan Your Escape!

    ERIC Educational Resources Information Center

    PTA Today, 1991

    1991-01-01

    Discusses the importance of home fire escape drills, detailing fire safety plans. Early detection and warning (smoke detectors) coupled with well-rehearsed escape plans help prevent serious injury. Children need to be taught about fire safety beginning at a very early age. (SM)

  13. 77 FR 32136 - Agency Information Collection Activities:

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-31

    ... Fire Safety Authority of Storage of Explosive Materials. (3) Agency form number, if any, and the... safety of emergency response personnel responding to fires at sites where explosives are stored. The information is provided both orally and in writing to the authority having jurisdiction for fire safety in the...

  14. 24 CFR 232.565 - Maximum loan amount.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Fire Safety Equipment Eligible Security Instruments § 232.565 Maximum loan amount. The principal amount of the loan shall not exceed the lower of the Commissioner's estimate of the cost of the fire safety... Secretary of Health and Human Services and the Commissioner to enhance the fire safety of the project, and...

  15. 24 CFR 232.565 - Maximum loan amount.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Fire Safety Equipment Eligible Security Instruments § 232.565 Maximum loan amount. The principal amount of the loan shall not exceed the lower of the Commissioner's estimate of the cost of the fire safety... Secretary of Health and Human Services and the Commissioner to enhance the fire safety of the project, and...

  16. 24 CFR 232.565 - Maximum loan amount.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Fire Safety Equipment Eligible Security Instruments § 232.565 Maximum loan amount. The principal amount of the loan shall not exceed the lower of the Commissioner's estimate of the cost of the fire safety... Secretary of Health and Human Services and the Commissioner to enhance the fire safety of the project, and...

  17. 30 CFR 57.4161 - Use of fire underground.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Use of fire underground. 57.4161 Section 57.4161 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention...

  18. 36 CFR 910.37 - Fire and life safety.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... that all buildings be equipped with an approved sprinkler system. ... 36 Parks, Forests, and Public Property 3 2014-07-01 2014-07-01 false Fire and life safety. 910.37... DEVELOPMENT AREA Standards Uniformly Applicable to the Development Area § 910.37 Fire and life safety. As a...

  19. 36 CFR 910.37 - Fire and life safety.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... that all buildings be equipped with an approved sprinkler system. ... 36 Parks, Forests, and Public Property 3 2012-07-01 2012-07-01 false Fire and life safety. 910.37... DEVELOPMENT AREA Standards Uniformly Applicable to the Development Area § 910.37 Fire and life safety. As a...

  20. 77 FR 2306 - Agency Information Collection Activities: Submission for OMB Review; Comment Request, Federal...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-17

    ... Request, Federal Hotel and Motel Fire Safety Declaration Form AGENCY: Federal Emergency Management Agency... Title: Federal Hotel and Motel Fire Safety Declaration Form. Type of information collection: Extension... Numbers: FEMA Form 516-0-1, Federal Hotel and Motel Fire Safety Declaration Form. Abstract: FEMA collects...

  1. A Lifetime for Fire Safety. Health (High School). Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the high school health component of a series of curriculum guides on fire and burn prevention. It is designed to meet the age-specific needs of ninth and tenth grade students. Objectives include: (1) reviewing comprehensive fire and burn prevention techniques and emergency actions; (2) developing an awareness of fire safety…

  2. Fire safety arrangement of inhabited pressurized compartments of manned spacecraft

    NASA Astrophysics Data System (ADS)

    Bolodian, Ivan; Melikhov, Anatoliy; Tanklevskiy, Leonid

    2017-06-01

    The article deals with innovative technical solutions that provide fire safety in inhabited pressurized compartments of manned spacecraft by means of a fireproof device of inhabited pressurized compartments via application of engineering means of fire prevention and fire spreading prevention by lowering fire load in an inhabited pressurized module up to the point when the maximum possible levels of fire factors in an inhabited pressurized compartment of a manned spacecraft are prevented. Represented technical solutions are used at the present time according to stated recommendations during provision of fire safety of equipment created by a number of Russian organizations for equipage of inhabited pressurized compartments of spacecraft of the Russian segment of International space station.

  3. Fight Fire with These Safety Strategies.

    ERIC Educational Resources Information Center

    Jackson, Lisa M.

    1998-01-01

    Provides expert guidelines on ways to keep schools and children safe from building fires, such as maintenance of exits for easy egress in emergencies, maintaining fire-protection systems, and utilizing evacuation planning and drilling. Highlights fire-safety ideas as part of school-building and renovation projects. (GR)

  4. How to Escape a Home Fire (Take This Safety Quiz).

    ERIC Educational Resources Information Center

    PTA Today, 1994

    1994-01-01

    A checklist/safety quiz from the National Fire Protection Association examines individual knowledge of how to escape if a home fire breaks out. The organization recommends that every household develop a fire escape plan and practice it at least twice a year. (SM)

  5. 29 CFR Appendix A to Subpart P to... - Model Fire Safety Plan (Non-Mandatory)

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Subpart P to Part 1915 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... Fire Protection in Shipyard Employment Pt. 1915, Subpt. P, App. A Appendix A to Subpart P to Part 1915... fire. D. Potential ignition sources for fires and how to control them. E. Types of fire protection...

  6. 29 CFR Appendix A to Subpart P to... - Model Fire Safety Plan (Non-Mandatory)

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Subpart P to Part 1915 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... Fire Protection in Shipyard Employment Pt. 1915, Subpt. P, App. A Appendix A to Subpart P to Part 1915... fire. D. Potential ignition sources for fires and how to control them. E. Types of fire protection...

  7. Fire prevention in Delaware: a case study of fire and life safety initiatives.

    PubMed

    Frattaroli, Shannon; Gielen, Andrea C; Piver-Renna, Jennifer; Pollack, Keshia M; Ta, Van M

    2011-01-01

    Injuries resulting from residential house fires are a significant public health issue. The fire service is engaged in fire prevention activities aimed at preventing fire-related morbidity and mortality. The fire service in Delaware is regarded by some leaders in the field as a model for fire and life safety education (FLSE). We identified 3 questions to guide this research. What is the culture and context of fire prevention in Delaware? What prevention programs and policies constitute Delaware's fire prevention efforts? What can be learned from select model programs regarding their impact, sustainability, strengths, limitations, and general applicability? A discussion of the lessons learned from Delaware's experience with FLSE initiatives concludes the article. We used a single case study design and collected and analyzed data from in-depth interviews, documents, and participant observation notes to address the research questions. Data were collected in Delaware. Interviewees included a purposeful sample of members of the Delaware fire service. Descriptions of the context in which fire prevention occurs, the initiatives underway, and the factors associated with successfully supporting fire prevention in the state. Data from 16 key informant interviews, relevant documents, and direct observations of FLSE events revealed a fire service rooted in tradition, dedication, and community. A compilation of state and local FLSE initiatives illustrates the diversity of FLSE in Delaware. Thematic analysis of the data emphasize the importance of a strategic, comprehensive, and coordinated approach to realizing success in Delaware's approach to FLSE. The fire service is an important part of the public health infrastructure. While their role as first responders is evident, their contributions to prevention are also significant. This research suggests ways to support fire service prevention efforts and more fully integrate their FLSE work into the public health infrastructure.

  8. Carbon Monoxide Safety

    MedlinePlus

    ... portable generators? Source: National Institute of Standards and Technology More information on carbon monoxide safety Heating fire safety NFPA Educational Messages Desk Reference – these messages provide fire and ...

  9. The Exposure Index: Developing firefighter safety performance measures

    Treesearch

    Dave Calkin; John Phipps; Tom Holmes; Jon Rieck; Matt Thompson

    2011-01-01

    A cornerstone of effective institutional learning and accountability is the development, tracking, and analysis of informative performance measures. In a previous issue of Fire Management Today ("A New Look at Risk Management," Winter 2011), a series of articles highlighted the importance of organizational safety and risk management and the challenges of...

  10. 41 CFR 102-80.105 - What information must be included in an equivalent level of safety analysis?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What information must be... Property Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Accident and Fire Prevention Equivalent Level...

  11. Research in fire prevention.

    PubMed

    Pearce, N

    1985-10-01

    This paper describes in broad terms, the fire testing programme we carried out on whole bed assemblies in 1984. It should be clear that the tests were carried out in a thoroughly rigorous scientific manner. As always there is more to be done. The immediate task of finding the so called 'safe' bed assembly is proceeding with the search this year for safer pillows. Softer barrier foams are now being produced and it may be that the NHS could use full depth foam mattresses rather than a barrier foam wrap. On the engineering side I have explained the false alarm problem, and I have reviewed some of the research we are doing to see that new technology is used to give us better systems in future. Life safety sprinkler systems give the possibility of truly active fire protection in patient areas. They will enhance fire safety but at the moment no trade-offs can be offered in other areas of fire protection--either active or passive. My final point is that although I have considered the Department's fire research by looking separately at specific projects, the fire safety of a hospital must always be considered as a total package. To be effective, individual components of fire safety must not be considered in isolation but as part of the overall fire safety system.

  12. 14 CFR 139.321 - Handling and storing of hazardous substances and materials.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...

  13. 14 CFR 139.321 - Handling and storing of hazardous substances and materials.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...

  14. 14 CFR 139.321 - Handling and storing of hazardous substances and materials.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...

  15. 14 CFR 139.321 - Handling and storing of hazardous substances and materials.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...

  16. 14 CFR 139.321 - Handling and storing of hazardous substances and materials.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...

  17. Firefighters United for Safety, Ethics, and Ecology (FUSEE): Torchbearers for a new fire management paradigm

    Treesearch

    Timothy Ingalsbee; Joseph Fox; Patrick Withen

    2007-01-01

    Firefighters United for Safety, Ethics, and Ecology (FUSEE) is a nonprofit organization promoting safe, ethical, ecological wildland fire management. FUSEE believes firefighter and community safety are ultimately interdependent with ethical public service, wildlands protection, and ecological restoration of fire-adapted ecosystems. Our members include current, former,...

  18. 24 CFR 232.510 - Commitment and commitment fee.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... of Fire Safety Equipment Fees and Charges § 232.510 Commitment and commitment fee. (a) Issuance of... setting forth the terms and conditions upon which the fire safety loan will be insured. (b) Type of... installation of the fire safety equipment, as determined by the Secretary of HHS. (c) Term of commitment. (1...

  19. 24 CFR 232.510 - Commitment and commitment fee.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... of Fire Safety Equipment Fees and Charges § 232.510 Commitment and commitment fee. (a) Issuance of... setting forth the terms and conditions upon which the fire safety loan will be insured. (b) Type of... installation of the fire safety equipment, as determined by the Secretary of HHS. (c) Term of commitment. (1...

  20. 24 CFR 232.510 - Commitment and commitment fee.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... of Fire Safety Equipment Fees and Charges § 232.510 Commitment and commitment fee. (a) Issuance of... setting forth the terms and conditions upon which the fire safety loan will be insured. (b) Type of... installation of the fire safety equipment, as determined by the Secretary of HHS. (c) Term of commitment. (1...

  1. Operation and Development Status of the Spacecraft Fire Experiments (Saffire)

    NASA Technical Reports Server (NTRS)

    Ruff, Gary A.; Urban, David L.

    2016-01-01

    Since 2012, a series of Spacecraft Fire Experiments (Saffire) have been under development by the Spacecraft Fire Safety Demonstration (SFS Demo) project, funded by NASA's Advanced Exploration Systems Division. The overall objective of this project is to reduce the uncertainty and risk associated with the design of spacecraft fire safety systems for NASA's exploration missions. The approach to achieving this goal has been to define, develop, and conduct experiments that address gaps in spacecraft fire safety knowledge and capabilities identified by NASA's Fire Safety System Maturation Team. The Spacecraft Fire Experiments (Saffire-I, -II, and -III) are material flammability tests at length scales that are realistic for a spacecraft fire in low-gravity. The specific objectives of these three experiments are to (1) determine how rapidly a large scale fire grows in low-gravity and (2) investigate the low-g flammability limits compared to those obtained in NASA's normal gravity material flammability screening test. The experiments will be conducted in Orbital ATK's Cygnus vehicle after it has unberthed from the International Space Station. The tests will be fully automated with the data downlinked at the conclusion of the test before the Cygnus vehicle reenters the atmosphere. This paper discusses the status of the Saffire-I, II, and III experiments followed by a review of the fire safety technology gaps that are driving the development of objectives for the next series of experiments, Saffire-IV, V, and VI.

  2. The influence of fire exposure on austenitic stainless steel for pressure vessel fitness-for-service assessment: Experimental research

    NASA Astrophysics Data System (ADS)

    Li, Bo; Shu, Wenhua; Zuo, Yantian

    2017-04-01

    The austenitic stainless steels are widely applied to pressure vessel manufacturing. The fire accident risk exists in almost all the industrial chemical plants. It is necessary to make safety evaluation on the chemical equipment including pressure vessels after fire. Therefore, the present research was conducted on the influences of fire exposure testing under different thermal conditions on the mechanical performance evolution of S30408 austenitic stainless steel for pressure vessel equipment. The metallurgical analysis described typical appearances in micro-structure observed in the material suffered by fire exposure. Moreover, the quantitative degradation of mechanical properties was investigated. The material thermal degradation mechanism and fitness-for-service assessment process of fire damage were further discussed.

  3. Safety Education. A Guide To Help Prevent Accidents Associated with the Home, Student Transportation, Disasters, Pedestrians, Passengers, Fires, Consumerism, Recreation.

    ERIC Educational Resources Information Center

    Texas Education Agency, Austin.

    This teacher's guide presents 10 instructional units for one portion of the Texas-approved course in driver and safety education. The units cover the following topics: what is safety?; accident causation and prevention; home safety; student transportation safety; disasters; pedestrian safety; passenger safety; fire safety; consumer safety; and…

  4. Risk-based Spacecraft Fire Safety Experiments

    NASA Technical Reports Server (NTRS)

    Apostolakis, G.; Catton, I.; Issacci, F.; Paulos, T.; Jones, S.; Paxton, K.; Paul, M.

    1992-01-01

    Viewgraphs on risk-based spacecraft fire safety experiments are presented. Spacecraft fire risk can never be reduced to a zero probability. Probabilistic risk assessment is a tool to reduce risk to an acceptable level.

  5. Advanced spacecraft fire safety: Proposed projects and program plan

    NASA Technical Reports Server (NTRS)

    Youngblood, Wallace W.; Vedha-Nayagam, M.

    1989-01-01

    A detailed review identifies spacecraft fire safety issues and the efforts for their resolution, particularly for the threats posed by the increased on-orbit duration, size, and complexity of the Space Station Freedom. Suggestions provided by a survey of Wyle consultants and outside fire safety experts were combined into 30 research and engineering projects. The projects were then prioritized with respect to urgency to meet Freedom design goals, status of enabling technology, cost, and so on, to yield 14 highest priority projects, described in terms of background, work breakdown structure, and schedule. These highest priority projects can be grouped into the thematic areas of fire detection, fire extinguishment, risk assessment, toxicology and human effects, and ground based testing. Recommendations for overall program management stress the need for NASA Headquarters and field center coordination, with information exchange through spacecraft fire safety oversight committees.

  6. An Educational Program Dealing with Fire Safety. Curriculum and Resource Guide.

    ERIC Educational Resources Information Center

    Rhode Island State Dept. of Education, Providence.

    A series of activities for fire safety education in grades K-12 is presented. The document is organized into three parts: grades K-3; 4-6; and 7-12. Each activity is preceded by general and specific concepts to be stressed. Concepts for grades K-3 stress usefulness and types of fire, fire drills, the fire fighting profession, and the…

  7. Fire Safety Power. Sixth Grade. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the sixth grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of sixth grade students, its objectives include: (1) developing a comprehensive understanding of fire physics, (2) evaluating electrical hazards and how to respond to those hazards, and (3)…

  8. Fire Safety: Any Time, Any Place. First Grade. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the first grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of first grade students, its objectives include acquiring basic knowledge of fire and burn hazards, developing a basic understanding of simple injury reduction, and encouraging parent involvement.…

  9. Ten Fire Safety Tips for Schools.

    ERIC Educational Resources Information Center

    Lake, James D.

    1999-01-01

    Provides 10 basic tips, compiled from the National Fire Protection Association's Life Safety Code 101, to ensure that educational facilities are fire safe. Tips include use of frequent and unexpected fire drills, limiting wall space of student artwork and teaching materials, being alert to preventing arson, planning speedy and safe emergency…

  10. 30 CFR 75.1103-1 - Automatic fire sensors.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic fire sensors. 75.1103-1 Section 75.1103-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... fire sensors. A fire sensor system shall be installed on each underground belt conveyor. Sensors so...

  11. 30 CFR 75.1103-1 - Automatic fire sensors.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Automatic fire sensors. 75.1103-1 Section 75.1103-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... fire sensors. A fire sensor system shall be installed on each underground belt conveyor. Sensors so...

  12. 30 CFR 75.1103-1 - Automatic fire sensors.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Automatic fire sensors. 75.1103-1 Section 75.1103-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... fire sensors. A fire sensor system shall be installed on each underground belt conveyor. Sensors so...

  13. 30 CFR 75.1103-1 - Automatic fire sensors.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Automatic fire sensors. 75.1103-1 Section 75.1103-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... fire sensors. A fire sensor system shall be installed on each underground belt conveyor. Sensors so...

  14. 30 CFR 75.1103-1 - Automatic fire sensors.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Automatic fire sensors. 75.1103-1 Section 75.1103-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... fire sensors. A fire sensor system shall be installed on each underground belt conveyor. Sensors so...

  15. The potential benefit of a home fire safety intervention during emergency medical services calls.

    PubMed

    Pirrallo, R G; Rubin, J M; Murawsky, G A

    1998-03-01

    To determine how often house fires occur at 1- and 2-family dwellings visited previously by emergency medical services (EMS) personnel and whether these visits were missed opportunities for a point-of-contact home fire safety intervention. A retrospective, consecutive, case series analysis of all Milwaukee Fire Department alarm responses during 1994 was performed. Measurements included date of service, type of response, property type, dollar loss estimate, number of injuries and fatalities, cause of alarm, and presence of an operational smoke detector. Descriptive, chi2, and relative risk statistics were used to describe the relationship between EMS responses and fire responses at 1- and 2-family dwellings. The Milwaukee Fire Department dispatched 94,378 requests for service to 43,556 addresses. 16,150 addresses generated multiple requests; 7.2% (1,162/16,150) were for an "alarm of fire" response [relative risk 1.83 (95% CI: 1.69-1.99) for addresses with multiple requests vs those with a single request for service]. Most [62% (721/1,162)] of the addresses were visited by EMS personnel prior to the alarm; 28% (205/721) were 1- and 2-family dwellings. A mean of 1.8 (376/205) EMS responses occurred prior to the "alarm of fire" response; 121 addresses received 1 response, 46 received 2, 18 received 3, and 20 received > or = 4 responses. Of 169 addresses with complete data, there was a total fire dollar loss of $1,963,020 (1994) along with 32 injuries and 0 fatalities. While 47% (80/169) of the 1- and 2-family dwellings had a smoke detector present, only 17% (29/169) of the dwellings had an operational smoke detector. A point-of-contact home fire safety intervention appears of potential benefit for frequent users of EMS care. Determination of the presence of an operational smoke detector in 1- and 2-family dwellings may be a useful injury prevention act during such EMS calls.

  16. 46 CFR 62.35-15 - Fire safety.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Requirements for Specific Types of Automated Vital Systems § 62.35-15 Fire safety. (a) All required fire pump remote control locations must include the controls necessary to charge the firemain and— (1) A firemain...

  17. 46 CFR 62.35-15 - Fire safety.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Requirements for Specific Types of Automated Vital Systems § 62.35-15 Fire safety. (a) All required fire pump remote control locations must include the controls necessary to charge the firemain and— (1) A firemain...

  18. 46 CFR 62.35-15 - Fire safety.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Requirements for Specific Types of Automated Vital Systems § 62.35-15 Fire safety. (a) All required fire pump remote control locations must include the controls necessary to charge the firemain and— (1) A firemain...

  19. Campus Fire Safety Today.

    ERIC Educational Resources Information Center

    Thompson, Mike

    2001-01-01

    Reviews information on recent college and university dormitory fire fatalities, and highlights five examples of building features reported to be major contributing factors in residence-hall fires. Explains how public awareness and expectations are affecting school dormitory safety. (GR)

  20. Smoke Detection: Critical Element of a University Residential Fire Safety Program.

    ERIC Educational Resources Information Center

    Robinson, Donald A.

    1979-01-01

    A program at the University of Massachusetts/Amherst to assess the fire protection needs of its residential system is described. The study culminated in a multiphase fire safety improvement plan. (JMF)

  1. 29 CFR 1915.501 - General provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard...

  2. 29 CFR 1915.501 - General provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard...

  3. 33 CFR 165.152 - Coast Guard Station Fire Island, Long Island, New York-safety zone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Coast Guard Station Fire Island, Long Island, New York-safety zone. 165.152 Section 165.152 Navigation and Navigable Waters COAST GUARD... § 165.152 Coast Guard Station Fire Island, Long Island, New York—safety zone. (a) Location. The...

  4. Fire Safety Trianing in Health Care Institutions.

    ERIC Educational Resources Information Center

    American Hospital Association, Chicago, IL.

    The manual details the procedures to be followed in developing and implementing a fire safety plan. The three main steps are first, to organize; second, to set up a procedure and put it in writing; and third, to train and drill employees and staff. Step 1 involves organizing a safety committee, appointing a fire marshall, and seeking help from…

  5. Using Modeling and Rehearsal to Teach Fire Safety to Children with Autism

    ERIC Educational Resources Information Center

    Garcia, David; Dukes, Charles; Brady, Michael P.; Scott, Jack; Wilson, Cynthia L.

    2016-01-01

    We evaluated the efficacy of an instructional procedure to teach young children with autism to evacuate settings and notify an adult during a fire alarm. A multiple baseline design across children showed that an intervention that included modeling, rehearsal, and praise was effective in teaching fire safety skills. Safety skills generalized to…

  6. A GIS-based approach for comparative analysis of potential fire risk assessment

    NASA Astrophysics Data System (ADS)

    Sun, Ying; Hu, Lieqiu; Liu, Huiping

    2007-06-01

    Urban fires are one of the most important sources of property loss and human casualty and therefore it is necessary to assess the potential fire risk with consideration of urban community safety. Two evaluation models are proposed, both of which are integrated with GIS. One is the single factor model concerning the accessibility of fire passage and the other is grey clustering approach based on the multifactor system. In the latter model, fourteen factors are introduced and divided into four categories involving security management, evacuation facility, construction resistance and fire fighting capability. A case study on campus of Beijing Normal University is presented to express the potential risk assessment models in details. A comparative analysis of the two models is carried out to validate the accuracy. The results are approximately consistent with each other. Moreover, modeling with GIS promotes the efficiency the potential risk assessment.

  7. Comparison of public safety provider injury rates.

    PubMed

    Suyama, Joe; Rittenberger, Jon C; Patterson, P Daniel; Hostler, David

    2009-01-01

    During normal operations, public safety personnel may become injured, leading them to seek medical care and possible time off. Examining the nature and patterns of injury may help to identify preventive health measures for all public safety personnel and address specific needs of each discipline based on actual risk. Objective. To determine the types and severity of injuries encountered by public safety personnel during routine work conditions within a single urban population. De-identified workers' compensation data for emergency medical services (EMS), fire, and police providers from one urban center between January 1, 2005, and May 31, 2007, were examined. Data included type of injury, severity of injury, and date of event. Severity was categorized as follows: lost time (type 1), medical evaluation (type 2), report only (type 3), restricted duty (type 4), and not reported (type 5). Analysis of variance (ANOVA) and a pairwise t-test between groups with a Bonferroni correction was performed to determine the relative risk of injuries between groups. During the 29-month interval, an average workforce of 850 firefighters, 194 EMS providers, and 850 police officers were employed. A total of 1,295 workers' compensation events were documented, with 243 (18%) reported from EMS, 477 (36%) from fire, and 608 (46%) from police. Type 1 injuries were more common in fire (39%) and police (38%) than EMS (23%). EMS had higher rates of lost work (type 1) and medical evaluations (type 2) than both fire and police. Workers' compensation events common to all bureaus were minor trauma (76%) and exposures to blood-borne pathogens (12%). Minor traumatic injuries, mostly associated with axial musculoskeletal strains and extremity injuries, were responsible for the majority of injuries resulting in missed work. Injuries more common in a specific bureau included motor vehicle crashes and gunshot wounds (police) and cardiovascular disease, burns, and heat illness (fire). Public safety personnel are affected by both profession-specific and non-profession-specific injuries. Overall, EMS has higher rates of missed time and medical evaluations than both fire and police. These data highlight the need to make direct comparisons of various public safety personnel bureaus using a common time interval and locale in order to rationally plan interventions and apply resources.

  8. Spacecraft Fire Safety: A Human Space Flight Program Perspective

    NASA Technical Reports Server (NTRS)

    Pedley, Michael D.

    2003-01-01

    This paper presents viewgraphs on the International Space Station's fire safety program from a human space flight perspective. The topics include: 1) Typical Manned Spacecraft Materials; 2) Typical Flammable Hardware Protection; 3) Materials Flammability; 4) Fire Retardants; 5) Nonflammable Foam Cushion Material; 6) Electrical Wire and Cable; 7) Russian Solid-Fuel Oxygen Generator (SFOG); 8) GOX Ignition Mechanisms; 9) Fire Detection; and 10) Fire Suppression.

  9. The development of the residential Fire H.E.L.P. tool kit: a resource to protect homebound older adults.

    PubMed

    Diekman, Shane; Huitric, Michele; Netterville, Linda

    2010-01-01

    This article describes the development of the Fire H.E.L.P. tool kit for training selected Meals On Wheels (MOW) staff in Texas to implement a fire safety program for homebound older adults. We used a formative evaluation approach during the tool kit's development, testing, and initial implementation stages. The tool kit includes instructional curricula on how to implement Fire H.E.L.P., a home assessment tool to determine a residence's smoke alarm needs, and fire safety educational materials. During the tool kit's pilot test, MOW participants showed enhanced fire safety knowledge and high levels of confidence about applying their newfound training skills. After the pilot test, MOW staff used the tool kit to conduct local training sessions, provide fire safety education, and install smoke alarms in the homes of older adults. We believe the approach used to develop this tool kit can be applied to education efforts for other, related healthy home topics.

  10. Overview of safety research

    NASA Technical Reports Server (NTRS)

    Enders, J. H.

    1978-01-01

    Aircraft safety is reviewed by first establishing a perspective of air transportation accidents as a function of calendar year, geographic area, and phase of flight, and then by describing the threats to safety and NASA research underway in the three representative areas of engine operational problems, meteorological phenomena, and fire. Engine rotor burst protection, aircraft nacelle fire extinguishment, the aircraft-weather interface, severe weather wind shears and turbulence, clear air turbulence, and lightning are among the topics covered. Fire impact management through fire resistant materials technology development is emphasized.

  11. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  12. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  13. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  14. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  15. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  16. 30 CFR 75.1103-5 - Automatic fire warning devices; actions and response.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... hours after the belt is stopped, unless an examination for hot rollers and fire is made as prescribed in... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Automatic fire warning devices; actions and... OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire...

  17. 30 CFR 75.1103-5 - Automatic fire warning devices; actions and response.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... hours after the belt is stopped, unless an examination for hot rollers and fire is made as prescribed in... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Automatic fire warning devices; actions and... OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire...

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laurinat, J.; Kesterson, M.; Hensel, S.

    The documented safety analysis for the Savannah River Site evaluates the consequences of a postulated 1000 °C fire in a glovebox. The radiological dose consequences for a pressurized release of plutonium oxide powder during such a fire depend on the maximum pressure that is attained inside the oxide storage vial. To enable evaluation of the dose consequences, pressure transients and venting flow rates have been calculated for exposure of the storage vial to the fire. A standard B vial with a capacity of approximately 8 cc was selected for analysis. The analysis compares the pressurization rate from heating and evaporationmore » of moisture adsorbed onto the plutonium oxide contents of the vial with the pressure loss due to venting of gas through the threaded connection between the vial cap and body. Tabulated results from the analysis include maximum pressures, maximum venting velocities, and cumulative vial volumes vented during the first 10 minutes of the fire transient. Results are obtained for various amounts of oxide in the vial, various amounts of adsorbed moisture, different vial orientations, and different surface fire exposures.« less

  19. Accidental fires in clinical laboratories.

    PubMed

    Hoeltge, G A; Miller, A; Klein, B R; Hamlin, W B

    1993-12-01

    The National Fire Protection Association, Quincy, Mass, estimates that 169 fires have occurred annually in health care, medical, and chemical laboratories. On the average, there are 13 civilian injuries and $1.5 million per year in direct property damage. Most fires in which the cause or ignition source can be identified originate in malfunctioning electrical equipment (41.6%) or in the facility's electrical distribution system (14.7%). The prevalence of fire safety deficiencies was measured in the College of American Pathologists Laboratory Accreditation Program. Of the 1732 inspected laboratories, 5.5% lacked records of electrical receptacle polarity and ground checks in the preceding year. Of these inspected laboratories, 4.7% had no or incomplete documentation of electrical safety checks on laboratory instruments. There was no evidence of quarterly fire exit drills in 9% of the laboratories. Deficiencies were also found in precautionary labeling (6.8%), in periodic review of safe work practices (4.2%), in the use of safety cans (3.7%), and in venting of flammable liquid storage areas (2.8%). Fire preparedness would be improved if all clinical laboratories had smoke detectors and automatic fire-extinguishing systems. In-service training courses in fire safety should be targeted to the needs of specific service areas.

  20. Systematic control of nonmetallic materials for improved fire safety

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The elements of a systematic fire safety program are summarized and consist of fire safety criteria, design considerations, testing of materials, development of nonmetallic materials, nonmetallic materials information systems, design reviews, and change control. The system described in this report was developed for the Apollo spacecraft. The system can, however, be tailored to many industrial, commercial, and military activities.

  1. Defining the Role and Responsibility of the Fire Service Within Homeland Security

    DTIC Science & Technology

    2010-03-01

    Occupational Safety and Health NPS Naval Postgraduate School NRF National Response Framework OSHA Occupational Safety and Health Administration ...Kingdom USAR Urban Search and Rescue USFA United States Fire Administration USMA United States Military Academy xiii ACKNOWLEDGMENTS I want...Association (NFPA), the Occupational Safety and Health Administration (OSHA), the United States Fire Administration (USFA), and the National Institute for

  2. Burns and Fire Safety

    MedlinePlus

    Number of Deaths Death Rate Burns and Fire Safety Fact Sheet (2015) Fatalities • 334 children ages 19 and under died from fires or burns ... burns were ages 4 and under. 1 The death rate for children this age (0.73 per 100, ...

  3. Directory of DOT Fire Research, 1979 edition

    DOT National Transportation Integrated Search

    1980-12-01

    This document presents the results of a survey of the fire safety projects conducted by the modal administrations of the U.S. Department of Transportation. Ongoing and recently completed modal fire safety projects for the period June 1978 to December...

  4. Modeling of Electrical Cable Failure in a Dynamic Assessment of Fire Risk

    NASA Astrophysics Data System (ADS)

    Bucknor, Matthew D.

    Fires at a nuclear power plant are a safety concern because of their potential to defeat the redundant safety features that provide a high level of assurance of the ability to safely shutdown the plant. One of the added complexities of providing protection against fires is the need to determine the likelihood of electrical cable failure which can lead to the loss of the ability to control or spurious actuation of equipment that is required for safe shutdown. A number of plants are now transitioning from their deterministic fire protection programs to a risk-informed, performance based fire protection program according to the requirements of National Fire Protection Association (NFPA) 805. Within a risk-informed framework, credit can be taken for the analysis of fire progression within a fire zone that was not permissible within the deterministic framework of a 10 CFR 50.48 Appendix R safe shutdown analysis. To perform the analyses required for the transition, plants need to be able to demonstrate with some level of assurance that cables related to safe shutdown equipment will not be compromised during postulated fire scenarios. This research contains the development of new cable failure models that have the potential to more accurately predict electrical cable failure in common cable bundle configurations. Methods to determine the thermal properties of the new models from empirical data are presented along with comparisons between the new models and existing techniques used in the nuclear industry today. A Dynamic Event Tree (DET) methodology is also presented which allows for the proper treatment of uncertainties associated with fire brigade intervention and its effects on cable failure analysis. Finally a shielding analysis is performed to determine the effects on the temperature response of a cable bundle that is shielded from a fire source by an intervening object such as another cable tray. The results from the analyses demonstrate that models of similar complexity to existing cable failure techniques and tuned to empirical data can better approximate the temperature response of a cables located in tightly packed cable bundles. The new models also provide a way to determine the conditions insides a cable bundle which allows for separate treatment of cables on the interior of the bundle from cables on the exterior of the bundle. The results from the DET analysis show that the overall assessed probability of cable failure can be significantly reduced by more realistically accounting for the influence that the fire brigade has on a fire progression scenario. The shielding analysis results demonstrate a significant reduction in the temperature response of a shielded versus a non-shielded cable bundle; however the computational cost of using a fire progression model that can capture these effects may be prohibitive for performing DET analyses with currently available computational fluid dynamics models and computational resources.

  5. Management of a fire in the operating room.

    PubMed

    Kaye, Alan David; Kolinsky, Daniel; Urman, Richard D

    2014-04-01

    Operating room (OR) fires remain a significant source of liability for anesthesia providers and injury for patients, despite existing practice guidelines and other improvements in operating room safety. Factors contributing to OR fires are well understood and these occurrences are generally preventable. OR personnel must be familiar with the fire triad which consists of a fuel supply, an oxidizing agent, and an ignition source. Existing evidence shows that OR-related fires can result in significant patient complications and malpractice claims. Steps to reduce fires include taking appropriate safety measures before a patient is brought to the OR, taking proper preventive measures during surgery, and effectively managing fire and patient complications when they occur. Decreasing the incidence of fires should be a team effort involving the entire OR personnel, including surgeons, anesthesia providers, nurses, scrub technologists, and administrators. Communication and coordination among members of the OR team is essential to creating a culture of safety.

  6. Metal fires and their implications for advanced reactors.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nowlen, Steven Patrick; Figueroa, Victor G.; Olivier, Tara Jean

    This report details the primary results of the Laboratory Directed Research and Development project (LDRD 08-0857) Metal Fires and Their Implications for Advance Reactors. Advanced reactors may employ liquid metal coolants, typically sodium, because of their many desirable qualities. This project addressed some of the significant challenges associated with the use of liquid metal coolants, primary among these being the extremely rapid oxidation (combustion) that occurs at the high operating temperatures in reactors. The project has identified a number of areas for which gaps existed in knowledge pertinent to reactor safety analyses. Experimental and analysis capabilities were developed in thesemore » areas to varying degrees. In conjunction with team participation in a DOE gap analysis panel, focus was on the oxidation of spilled sodium on thermally massive surfaces. These are spills onto surfaces that substantially cool the sodium during the oxidation process, and they are relevant because standard risk mitigation procedures seek to move spill environments into this regime through rapid draining of spilled sodium. While the spilled sodium is not quenched, the burning mode is different in that there is a transition to a smoldering mode that has not been comprehensively described previously. Prior work has described spilled sodium as a pool fire, but there is a crucial, experimentally-observed transition to a smoldering mode of oxidation. A series of experimental measurements have comprehensively described the thermal evolution of this type of sodium fire for the first time. A new physics-based model has been developed that also predicts the thermal evolution of this type of sodium fire for the first time. The model introduces smoldering oxidation through porous oxide layers to go beyond traditional pool fire analyses that have been carried out previously in order to predict experimentally observed trends. Combined, these developments add significantly to the safety analysis capabilities of the advanced-reactor community for directly relevant scenarios. Beyond the focus on the thermally-interacting and smoldering sodium pool fires, experimental and analysis capabilities for sodium spray fires have also been developed in this project.« less

  7. Spacecraft fire-safety experiments for space station: Technology development mission

    NASA Technical Reports Server (NTRS)

    Youngblood, Wallace W.

    1988-01-01

    Three concept designs for low-gravity, fire-safety related experiments are presented, as selected for the purpose of addressing key issues of enhancing safety and yet encouraging access to long-duration, manned spacecraft such as the NASA space station. The selected low-gravity experiments are the following: (1) an investigation of the flame-spread rate and combustion-product evolution of the burning of typical thicknesses of spacecraft materials in very low-speed flows; (2) an evaluation of the interaction of fires and candidate extinguishers in various fire scenarios; and (3) an investigation of the persistence and propagation of smoldering and deep-seated combustion. Each experiment is expected to provide fundamental combustion-science data, as well as the fire-safety applications, and each requires the unique long-duration, low-gravity environment of the space station. Two generic test facilities, i.e., the Combustion Tunnel Facility and the Combustion Facility, are proposed for space station accommodation to support the selected experiments. In addition, three near-term, fire-safety related experiments are described along with other related precursor activities.

  8. Wire insulation degradation and flammability in low gravity

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1994-01-01

    This view-graph presentation covers the following topics: an introduction to spacecraft fire safety, concerns in fire prevention in low gravity, shuttle wire insulation flammability experiment, drop tower risk-based fire safety experiment, and experimental results, conclusions, and proposed studies.

  9. Fire in the OR--developing a fire safety plan.

    PubMed

    McCarthy, Patricia M; Gaucher, Kenneth A

    2004-03-01

    Approximately 100 operating room fire occur each year in the United States. Although rare, fire in a perioperative setting can be disastrous for both patients and staff members. It is crucial that all perioperative departments have a well thought out and previously rehearsed fire plan in place. Multidisciplinary planning and implementation of regularly scheduled and scripted fire drills are essential to prevent adverse outcomes. Fire drills ensure that all staff members are familiar with the use and location of fire pull stations, fire extinguishers, and fire blankets. Fire drills also prepare staff members to evacuate the OR area if necessary. This article provides the information and framework necessary to develop and implement comprehensive OR fire safety plans that could make the difference between life and death in a fire emergency.

  10. 46 CFR 160.170-3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety... Safety of Life at Sea, 1974, as amended. [USCG-2010-0048, 76 FR 63007, Oct. 11, 2011, as amended by USCG...

  11. 46 CFR 160.133-3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety... Convention for the Safety of Life at Sea, 1974, as amended. [USCG-2010-0048, 76 FR 62983, Oct. 11, 2011, as...

  12. 46 CFR 160.170-3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety... Safety of Life at Sea, 1974, as amended. [USCG-2010-0048, 76 FR 63007, Oct. 11, 2011, as amended by USCG...

  13. Comparative Analysis of the Reliability of Steel Structure with Pinned and Rigid Nodes Subjected to Fire

    NASA Astrophysics Data System (ADS)

    Kubicka, Katarzyna; Radoń, Urszula; Szaniec, Waldemar; Pawlak, Urszula

    2017-10-01

    The paper concerns the reliability analysis of steel structures subjected to high temperatures of fire gases. Two types of spatial structures were analysed, namely with pinned and rigid nodes. The fire analysis was carried out according to prescriptions of Eurocode. The static-strength analysis was conducted using the finite element method (FEM). The MES3D program, developed by Szaniec (Kielce University of Technology, Poland), was used for this purpose. The results received from MES3D made it possible to carry out the reliability analysis using the Numpress Explore program that was developed at the Institute of Fundamental Technological Research of the Polish Academy of Sciences [9]. The measurement of reliability of structures is the Hasofer-Lind reliability index (β). The reliability analysis was carried out according to approximation (FORM, SORM) and simulation (Importance Sampling, Monte Carlo) methods. As the fire progresses, the value of reliability index decreases. The analysis conducted for the study made it possible to evaluate the impact of node types on those changes. In real structures, it is often difficult to define correctly types of nodes, so some simplifications are made. The presented analysis contributes to the recognition of consequences of such assumptions for the safety of structures, subjected to fire.

  14. Nonfatal residential fire-related injuries treated in emergency departments--United States, 2001.

    PubMed

    2003-09-26

    During 2000, the most recent year for which national mortality data are available, 3,907 persons died in the United States from fire-related injuries; residential fires accounted for 2,955 (76%) of these deaths. The National Fire Protection Association (NFPA) reported that approximately 396,500 residential fires occurred in 2001. Injuries from residential fires are preventable by improving awareness of the common causes of fires and by using simple interventions (e.g., properly maintained smoke alarms and fire escape plans). Surveillance of fire-related injuries can aid prevention by increasing the understanding of these injuries and by identifying at-risk populations to target for interventions and education. To characterize nonfatal residential fire-related injuries treated in U.S. hospital emergency departments (EDs) during 2001, CDC analyzed data from the National Electronic Injury Surveillance System-All Injury Program (NEISS-AIP). This report summarizes the results of that analysis, which indicate that, in 2001, an estimated 25,717 nonfatal residential fire-related injuries were treated in U.S. hospital EDs. Fire prevention and safety interventions and education should target at-risk populations for fire-related injuries.

  15. Safety in the Chemical Laboratory: Advanced Firemanship: How to Teach Your Audience a Lesson.

    ERIC Educational Resources Information Center

    Pitt, Martin J.

    1984-01-01

    Provides tips to assist in preparing a training program designed to show that: (1) fire is dangerous; (2) ordinary individuals can neither understand fire nor extinguish it; and (3) a fire safety officer can do both. (JN)

  16. Modelling Behaviour of a Carbon Epoxy Composite Exposed to Fire: Part I-Characterisation of Thermophysical Properties.

    PubMed

    Tranchard, Pauline; Samyn, Fabienne; Duquesne, Sophie; Estèbe, Bruno; Bourbigot, Serge

    2017-05-04

    Thermophysical properties of a carbon-reinforced epoxy composite laminate (T700/M21 composite for aircraft structures) were evaluated using different innovative characterisation methods. Thermogravimetric Analysis (TGA), Simultaneous Thermal analysis (STA), Laser Flash analysis (LFA), and Fourier Transform Infrared (FTIR) analysis were used for measuring the thermal decomposition, the specific heat capacity, the anisotropic thermal conductivity of the composite, the heats of decomposition and the specific heat capacity of released gases. It permits to get input data to feed a three-dimensional (3D) model given the temperature profile and the mass loss obtained during well-defined fire scenarios (model presented in Part II of this paper). The measurements were optimised to get accurate data. The data also permit to create a public database on an aeronautical carbon fibre/epoxy composite for fire safety engineering.

  17. 10 CFR 830.204 - Documented safety analysis.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., and accident conditions, including consideration of natural and man-made external events... radioactive and other hazardous materials, and consideration of the need for analysis of accidents which may... preparedness, fire protection, waste management, and radiation protection; and (6) With respect to a nonreactor...

  18. 10 CFR 830.204 - Documented safety analysis.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., and accident conditions, including consideration of natural and man-made external events... radioactive and other hazardous materials, and consideration of the need for analysis of accidents which may... preparedness, fire protection, waste management, and radiation protection; and (6) With respect to a nonreactor...

  19. 10 CFR 830.204 - Documented safety analysis.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., and accident conditions, including consideration of natural and man-made external events... radioactive and other hazardous materials, and consideration of the need for analysis of accidents which may... preparedness, fire protection, waste management, and radiation protection; and (6) With respect to a nonreactor...

  20. 10 CFR 830.204 - Documented safety analysis.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., and accident conditions, including consideration of natural and man-made external events... radioactive and other hazardous materials, and consideration of the need for analysis of accidents which may... preparedness, fire protection, waste management, and radiation protection; and (6) With respect to a nonreactor...

  1. 75 FR 44720 - Safety Zone; Live-Fire Gun Exercise, M/V Del Monte, James River, VA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-29

    ...-AA00 Safety Zone; Live-Fire Gun Exercise, M/V Del Monte, James River, VA AGENCY: Coast Guard, DHS... mariners from the hazards associated with live fire and explosive training events. DATES: This rule is... Hampton Roads was notified that the U.S. Navy will conduct a live fire and explosive training event...

  2. 36 CFR Appendix B to Part 1234 - Alternative Certified Fire-Safety Detection and Suppression System(s)

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the system at the base of the main sprinkler riser. l. Fire hydrants must be located within 250 feet... Suppression System(s) 1. General. This Appendix B contains information on the Fire-safety Detection and Suppression System(s) tested by NARA through independent live fire testing that are certified to meet the...

  3. 36 CFR Appendix B to Part 1234 - Alternative Certified Fire-Safety Detection and Suppression System(s)

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the system at the base of the main sprinkler riser. l. Fire hydrants must be located within 250 feet... Suppression System(s) 1. General. This Appendix B contains information on the Fire-safety Detection and Suppression System(s) tested by NARA through independent live fire testing that are certified to meet the...

  4. 36 CFR Appendix B to Part 1234 - Alternative Certified Fire-Safety Detection and Suppression System(s)

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the system at the base of the main sprinkler riser. l. Fire hydrants must be located within 250 feet... Suppression System(s) 1. General. This Appendix B contains information on the Fire-safety Detection and Suppression System(s) tested by NARA through independent live fire testing that are certified to meet the...

  5. Fire Safety for Consumers. Economics (High School). Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the high school economics component of a series of curriculum guides on fire and burn prevention. It is designed to meet the age-specific needs of eleventh and twelfth grade students. Objectives include: (1) developing an awareness of adult responsibilities to preserve family, property, and economy; (2) preparing for…

  6. Large-Scale Spacecraft Fire Safety Tests

    NASA Technical Reports Server (NTRS)

    Urban, David; Ruff, Gary A.; Ferkul, Paul V.; Olson, Sandra; Fernandez-Pello, A. Carlos; T'ien, James S.; Torero, Jose L.; Cowlard, Adam J.; Rouvreau, Sebastien; Minster, Olivier; hide

    2014-01-01

    An international collaborative program is underway to address open issues in spacecraft fire safety. Because of limited access to long-term low-gravity conditions and the small volume generally allotted for these experiments, there have been relatively few experiments that directly study spacecraft fire safety under low-gravity conditions. Furthermore, none of these experiments have studied sample sizes and environment conditions typical of those expected in a spacecraft fire. The major constraint has been the size of the sample, with prior experiments limited to samples of the order of 10 cm in length and width or smaller. This lack of experimental data forces spacecraft designers to base their designs and safety precautions on 1-g understanding of flame spread, fire detection, and suppression. However, low-gravity combustion research has demonstrated substantial differences in flame behavior in low-gravity. This, combined with the differences caused by the confined spacecraft environment, necessitates practical scale spacecraft fire safety research to mitigate risks for future space missions. To address this issue, a large-scale spacecraft fire experiment is under development by NASA and an international team of investigators. This poster presents the objectives, status, and concept of this collaborative international project (Saffire). The project plan is to conduct fire safety experiments on three sequential flights of an unmanned ISS re-supply spacecraft (the Orbital Cygnus vehicle) after they have completed their delivery of cargo to the ISS and have begun their return journeys to earth. On two flights (Saffire-1 and Saffire-3), the experiment will consist of a flame spread test involving a meter-scale sample ignited in the pressurized volume of the spacecraft and allowed to burn to completion while measurements are made. On one of the flights (Saffire-2), 9 smaller (5 x 30 cm) samples will be tested to evaluate NASAs material flammability screening tests. The first flight (Saffire-1) is scheduled for July 2015 with the other two following at six-month intervals. A computer modeling effort will complement the experimental effort. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew removes the need for strict containment of combustion products. This will facilitate the first examination of fire behavior on a scale that is relevant to spacecraft fire safety and will provide unique data for fire model validation.

  7. 75 FR 17644 - Update to NFPA 101, Life Safety Code, for State Home Facilities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-07

    ... DEPARTMENT OF VETERANS AFFAIRS 38 CFR Part 51 RIN 2900-AN59 Update to NFPA 101, Life Safety Code... certain provisions of the 2009 edition of the National Fire Protection Association's NFPA 101, Life Safety... standards regarding life safety and fire safety. DATES: Written comments must be received by VA on or before...

  8. Microbiological corrosion of ASTM SA105 carbon steel pipe for industrial fire water usage

    NASA Astrophysics Data System (ADS)

    Chidambaram, S.; Ashok, K.; Karthik, V.; Venkatakrishnan, P. G.

    2018-02-01

    The large number of metallic systems developed for last few decades against both general uniform corrosion and localized corrosion. Among all microbiological induced corrosion (MIC) is attractive, multidisciplinary and complex in nature. Many chemical processing industries utilizes fresh water for fire service to nullify major/minor fire. One such fire water service line pipe attacked by micro-organisms leads to leakage which is industrially important from safety point of view. Also large numbers of leakage reported in similar fire water service of nearby food processing plant, paper & pulp plant, steel plant, electricity board etc…In present investigation one such industrial fire water service line failure analysis of carbon steel line pipe was analyzed to determine the cause of failure. The water sample subjected to various chemical and bacterial analyses. Turbidity, pH, calcium hardness, free chlorine, oxidation reduction potential, fungi, yeasts, sulphide reducing bacteria (SRB) and total bacteria (TB) were measured on water sample analysis. The corrosion rate was measured on steel samples and corrosion coupon measurements were installed in fire water for validating non flow assisted localized corrosion. The sulphide reducing bacteria (SRB) presents in fire water causes a localized micro biological corrosion attack of line pipe.

  9. Fire hazard considerations for composites in vehicle design

    NASA Technical Reports Server (NTRS)

    Gordon, Rex B.

    1994-01-01

    Military ground vehicles fires are a significant cause of system loss, equipment damage, and crew injury in both combat and non-combat situations. During combat, the ability to successfully fight an internal fire, without losing fighting and mobility capabilities, is often the key to crew survival and mission success. In addition to enemy hits in combat, vehicle fires are initiated by electrical system failures, fuel line leaks, munitions mishaps and improper personnel actions. If not controlled, such fires can spread to other areas of the vehicle, causing extensive damage and the potential for personnel injury and death. The inherent fire safety characteristics (i.e. ignitability, compartments of these vehicles play a major roll in determining rather a newly started fire becomes a fizzle or a catastrophe. This paper addresses a systems approach to assuring optimum vehicle fire safety during the design phase of complex vehicle systems utilizing extensive uses of composites, plastic and related materials. It provides practical means for defining the potential fire hazard risks during a conceptual design phase, and criteria for the selection of composite materials based on its fire safety characteristics.

  10. Risks and issues in fire safety on the Space Station

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1993-01-01

    A fire in the inhabited portion of a spacecraft is a greatly feared hazard, but fire protection in space operations is complicated by two factors. First, the spacecraft cabin is an enclosed volume, which limits the resources for fire fighting and the options for crew escape. Second, an orbiting spacecraft experiences a balance of forces, creating a near-zero-gravity (microgravity) environment that profoundly affects the characteristics of fire initiation, spread, and suppression. The current Shuttle Orbiter is protected by a fire-detection and suppression system whose requirements are derived of necessity from accepted terrestrial and aircraft standards. While experience has shown that Shuttle fire safety is adequate, designers recognize that improved systems to respond specifically to microgravity fire characteristics are highly desirable. Innovative technology is particularly advisable for the Space Station, a forthcoming space community with a complex configuration and long-duration orbital missions, in which the effectiveness of current fire-protection systems is unpredictable. The development of risk assessments to evaluate the probabilities and consequences of fire incidents in spacecraft are briefly reviewed. It further discusses the important unresolved issues and needs for improved fire safety in the Space Station, including those of material selection, spacecraft atmospheres, fire detection, fire suppression, and post-fire restoration.

  11. Fighting Fire with Fire.

    ERIC Educational Resources Information Center

    Spoor, Dana L.

    1996-01-01

    School districts are integrating security and life-safety systems into school buildings to protect students and property. This proactive approach includes sprinkler systems, fire alarms, and security systems that monitor door movement. Some school districts that are incorporating the latest life-safety technology are in Missouri, Ohio, California,…

  12. Working toward the elimination of residential fire deaths: the Centers for Disease Control and Prevention's Smoke Alarm Installation and Fire Safety Education (SAIFE) program.

    PubMed

    Ballesteros, Michael F; Jackson, Mark L; Martin, Maurice W

    2005-01-01

    To address residential fires and related injuries, the Centers for Disease Control and Prevention funds state health departments to deliver a Smoke Alarm Installation and Fire Safety Education (SAIFE) program in high-risk homes in 16 states. This program involves recruiting local communities and community partners, hiring a local coordinator, canvassing neighborhood homes, installing long-lasting lithium-powered smoke alarms, and providing general fire safety education and 6-month follow-up to determine alarm functionality. Local fire departments are vital community partners in delivering this program. Since the program's inception, more than 212,000 smoke alarms have been installed in more than 126,000 high-risk homes. Additionally, approximately 610 lives have potentially been saved as a result of a program alarm that provided early warning to a dangerous fire incident.

  13. 30 CFR 56.4101 - Warning signs.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control... open flames shall be posted where a fire or explosion hazard exists. ...

  14. 30 CFR 57.4101 - Warning signs.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control... open flames shall be posted where a fire or explosion hazard exists. ...

  15. 30 CFR 56.4530 - Exits.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control... a sufficient number of exits to permit prompt escape in case of fire. ...

  16. Comparison of the characteristics of fire and non-fire households in the 2004-2005 survey of fire department-attended and unattended fires.

    PubMed

    Greene, Michael A

    2012-06-01

    Comparison of characteristics of fire with non-fire households to determine factors differentially associated with fire households (fire risk factors). National household telephone survey in 2004-2005 by the US Consumer Product Safety Commission with 916 fire households and a comparison sample of 2161 non-fire households. There were an estimated 7.4 million fires (96.6% not reported to fire departments) with 130,000 injuries. Bivariate analysis and multivariate logistic regression analyses to assess differences in household characteristics. Significant factors associated with fire households were renting vs. owning (OR 1.988 p<0.0001); household members under 18 year of age (OR 1.277 p<0.0001); lack of residents over 64 years old (OR 0.552 p=0.0007); and college or higher education (some college OR 1.444 p=0.0360, college graduate OR 1.873, p<0.0001, postgraduate OR 2.156 p<0.0001). Not significant were age of house; race; ethnicity; and income. Number of smokers was borderline significant (OR 1.132 p=0.1019) but was significant in the subset of fire households with non-cooking fires (OR 1.383 p=0.0011). Single family houses were associated with non-fire households in the bivariate analysis but not in the multivariate analyses. Renting, household members under 18 years old and smokers are risk factors for unattended fires, similar to the literature for fatal and injury fires. Differences included household members over 65 years old (associated with non-fire households), college/postgraduate education (associated with fire households) and lack of significance of income. Preventing cooking fires (64% of survey incidents), smoking prevention efforts and fire prevention education for families with young children have the potential for reducing unattended fires and injuries.

  17. Analysis of firetruck crashes and associated firefighter injuries in the United States.

    PubMed

    Donoughe, Kelly; Whitestone, Jennifer; Gabler, Hampton C

    2012-01-01

    Motor vehicle crashes are the second leading cause of death for on-duty firefighters. Firetruck crashes, occurring at a rate of approximately 30,000 crashes per year, have potentially dire consequences for the vehicle occupants and for the community if the firetruck was traveling to provide emergency services. Data from the United States Fire Administration and the National Highway Traffic Safety Administration shows that firefighters neglect to buckle their seatbelts while traveling in a fire apparatus, thus putting themselves at a high risk for injuries if the truck crashes, especially in rollover crashes. Despite national regulations and departmental guidelines aiming to improve safety on fire apparatuses, belt use among firefighters remains dangerously low. The results from this study indicate that further steps need to be taken to improve belt use. One promising solution would be to redesign firetruck seatbelts to improve the ease of buckling and to accommodate wider variations in firefighter sizes.

  18. Analysis of Firetruck Crashes and Associated Firefighter Injuries in the United States

    PubMed Central

    Donoughe, Kelly; Whitestone, Jennifer; Gabler, Hampton C.

    2012-01-01

    Motor vehicle crashes are the second leading cause of death for on-duty firefighters. Firetruck crashes, occurring at a rate of approximately 30,000 crashes per year, have potentially dire consequences for the vehicle occupants and for the community if the firetruck was traveling to provide emergency services. Data from the United States Fire Administration and the National Highway Traffic Safety Administration shows that firefighters neglect to buckle their seatbelts while traveling in a fire apparatus, thus putting themselves at a high risk for injuries if the truck crashes, especially in rollover crashes. Despite national regulations and departmental guidelines aiming to improve safety on fire apparatuses, belt use among firefighters remains dangerously low. The results from this study indicate that further steps need to be taken to improve belt use. One promising solution would be to redesign firetruck seatbelts to improve the ease of buckling and to accommodate wider variations in firefighter sizes. PMID:23169118

  19. 24 CFR 232.620 - Determination of compliance by HHS.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... AUTHORITIES MORTGAGE INSURANCE FOR NURSING HOMES, INTERMEDIATE CARE FACILITIES, BOARD AND CARE HOMES, AND... of Fire Safety Equipment Special Requirements § 232.620 Determination of compliance by HHS. An... the fire safety equipment has been installed, will be in compliance with the HHS requirements for fire...

  20. Children's Knowledge of Fire Safety. Stage 2. The Final Report for the New Zealand Fire Service.

    ERIC Educational Resources Information Center

    Dunn, Karyn; Renwick, Margery

    In 1991 the New Zealand Fire Service planned a primary school fire-safety education program for children from new entrants to form 2. The program introduces a new module to the children each year of their primary education. This study was undertaken in an attempt to measure the effectiveness of the program. A sample of 1,089 children completed…

  1. Engineering and Development Program Plan, Aircraft Cabin Fire Safety.

    DTIC Science & Technology

    1980-06-01

    relative to a postcrash fuel fire, or whether advanced materials provide a significant safety benefit in comparison to inservice materials. if either...have always been controlled by early detection and prompt extinguishment action by effectively trained crew members. In addition, the fire resistant...occupants. g. Develop a computer fire test data bank with broad user availability for inservice and candidate cabin interior materials. h. Identify

  2. Ignorance and Hazards in Academe: The Dilemma of Fire Safety in American Higher Education.

    ERIC Educational Resources Information Center

    Crnkovich, John J.; Dye, Charles M.

    An examination was made of five major campus fires between 1971 and 1983 in an attempt to better understand the fire hazards associated with the operation of a modern U.S. college or university campus. Overall research revealed a general lack of interest in campus fire safety by colleges and universities in the United States and Canada. Analysis…

  3. Final Report: Fire Prevention, Detection, and Suppression Project, Exploration Technology Development Program

    NASA Technical Reports Server (NTRS)

    Ruff, Gary A.

    2011-01-01

    The Fire Prevention, Detection, and Suppression (FPDS) project is a technology development effort within the Exploration Technology Development Program of the Exploration System Missions Directorate (ESMD) that addresses all aspects of fire safety aboard manned exploration systems. The overarching goal for work in the FPDS area is to develop technologies that will ensure crew health and safety on exploration missions by reducing the likelihood of a fire, or, if one does occur, minimizing the risk to the crew, mission, or system. This is accomplished by addressing the areas of (1) fire prevention and material flammability, (2) fire signatures and detection, and (3) fire suppression and response. This report describes the outcomes of this project from the formation of the Exploration Technology Development Program (ETDP) in October 2005 to September 31, 2010 when the Exploration Technology Development Program was replaced by the Enabling Technology Development and Demonstration Program. NASA s fire safety work will continue under this new program and will build upon the accomplishments described herein.

  4. Microfabricated Chemical Sensors for Aerospace Fire Detection Applications

    NASA Technical Reports Server (NTRS)

    Hunter, Gary W.; Neudeck, Philip G.; Fralick, Gustave; Thomas, Valarie; Makel, D.; Liu, C. C.; Ward, B.; Wu, Q. H.

    2001-01-01

    The detection of fires on-board commercial aircraft is extremely important for safety reasons. Although dependable fire detection equipment presently exists within the cabin, detection of fire within the cargo hold has been less reliable and susceptible to false alarms. A second, independent method of fire detection to complement the conventional smoke detection techniques, such as the measurement of chemical species indicative of a fire, will help reduce false alarms and improve aircraft safety. Although many chemical species are indicative of a fire, two species of particular interest are CO and CO2. This paper discusses microfabricated chemical sensor development tailored to meet the needs of fire safety applications. This development is based on progress in three types of technology: 1) Micromachining and microfabrication (Microsystem) technology to fabricate miniaturized sensors. 2) The use of nanocrystalline materials to develop sensors with improved stability combined with higher sensitivity. 3) The development of high temperature semiconductors, especially silicon carbide. The individual sensor being developed and their level of maturity will be presented.

  5. School-based prevention program associated with increased short- and long-term retention of safety knowledge.

    PubMed

    Klas, Karla S; Vlahos, Peter G; McCully, Michael J; Piche, David R; Wang, Stewart C

    2015-01-01

    Validation of program effectiveness is essential in justifying school-based injury prevention education. Although Risk Watch (RW) targets burn, fire, and life safety, its effectiveness has not been previously evaluated in the medical literature. Between 2007 and 2012, a trained fire service public educator (FSPE) taught RW to all second grade students in one public school district. The curriculum was delivered in 30-minute segments for 9 consecutive weeks via presentations, a safety smoke house trailer, a model-sized hazard house, a student workbook, and parent letters. A written pre-test (PT) was given before RW started, a post-test (PT#1) was given immediately after RW, and a second post-test (PT#2) was administered to the same students the following school year (ranging from 12 to 13 months after PT). Students who did not complete the PT or at least one post-test were excluded. Comparisons were made by paired t-test, analysis of variance, and regression analysis. After 183 (8.7%) were excluded for missing tests, 1,926 remaining students scored significantly higher (P = .0001) on PT#1 (mean 14.8) and PT#2 (mean 14.7) than the PT (mean 12.1). There was 1 FSPE and 36 school teachers with class size ranging from 10 to 27 (mean 21.4). Class size was not predictive of test score improvement (R = 0%), while analysis of variance showed that individual teachers trended toward some influence. This 6-year prospective study demonstrated that the RW program delivered by an FSPE effectively increased short-term knowledge and long-term retention of fire/life safety in early elementary students. Collaborative partnerships are critical to preserving community injury prevention education programs.

  6. 30 CFR 57.4600 - Extinguishing equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....4600 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention... electrically conductive extinguishing agent could create an electrical hazard, a multipurpose dry-chemical fire...

  7. 30 CFR 56.4500 - Heat sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control... shall be separated from combustible materials if a fire hazard could be created. ...

  8. 30 CFR 56.4600 - Extinguishing equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....4600 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and... conductive extinguishing agent could create an electrical hazard, a multipurpose dry-chemical fire...

  9. 30 CFR 57.4500 - Heat sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control... shall be separated from combustible materials if a fire hazard could be created. ...

  10. 30 CFR 57.4532 - Blacksmith shops.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and... combustion; and (c) Inspected for smoldering fires at the end of each shift. ...

  11. 29 CFR 1926.24 - Fire protection and prevention.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION General Safety and Health... and maintenance of an effective fire protection and prevention program at the job site throughout all...

  12. Bridging the divide between fire safety research and fighting fire safely: How do we convey research innovation to contribute more effectively to wildland firefighter safety?

    Treesearch

    Theodore Ted Adams; Bret W. Butler; Sara Brown; Vita Wright; Anne Black

    2017-01-01

    Creating a safe workplace for wildland firefighters has long been at the centre of discussion for researchers and practitioners. The goal of wildland fire safety research has been to protect operational firefighters, yet its contributions often fall short of potential because much is getting lost in the translation of peer-reviewed results to potential and intended...

  13. Fault tree analysis of fire and explosion accidents for dual fuel (diesel/natural gas) ship engine rooms

    NASA Astrophysics Data System (ADS)

    Guan, Yifeng; Zhao, Jie; Shi, Tengfei; Zhu, Peipei

    2016-09-01

    In recent years, China's increased interest in environmental protection has led to a promotion of energy-efficient dual fuel (diesel/natural gas) ships in Chinese inland rivers. A natural gas as ship fuel may pose dangers of fire and explosion if a gas leak occurs. If explosions or fires occur in the engine rooms of a ship, heavy damage and losses will be incurred. In this paper, a fault tree model is presented that considers both fires and explosions in a dual fuel ship; in this model, dual fuel engine rooms are the top events. All the basic events along with the minimum cut sets are obtained through the analysis. The primary factors that affect accidents involving fires and explosions are determined by calculating the degree of structure importance of the basic events. According to these results, corresponding measures are proposed to ensure and improve the safety and reliability of Chinese inland dual fuel ships.

  14. 41 CFR 301-11.11 - How do I select lodging and make lodging reservations?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... always stay in a “fire safe” facility. This is a facility that meets the fire safety requirements of the Hotel and Motel Fire Safety Act of 1990 (the Act), as amended (see 5 U.S.C. 5707a). (c) When selecting a...

  15. 41 CFR 301-11.11 - How do I select lodging and make lodging reservations?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... always stay in a “fire safe” facility. This is a facility that meets the fire safety requirements of the Hotel and Motel Fire Safety Act of 1990 (the Act), as amended (see 5 U.S.C. 5707a). (c) When selecting a...

  16. 41 CFR 301-11.11 - How do I select lodging and make lodging reservations?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... always stay in a “fire safe” facility. This is a facility that meets the fire safety requirements of the Hotel and Motel Fire Safety Act of 1990 (the Act), as amended (see 5 U.S.C. 5707a). (c) When selecting a...

  17. 77 FR 17504 - Agency Information Collection Activities: Proposed Collection; Comments Requested: Notification...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-26

    ...: Notification to Fire Safety Authority of Storage of Explosive Materials. (3) Agency form number, if any, and... provided both orally and in writing to the authority having jurisdiction for fire safety in the locality in...] Agency Information Collection Activities: Proposed Collection; Comments Requested: Notification to Fire...

  18. 30 CFR 77.1913 - Fire-resistant wood.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Fire-resistant wood. 77.1913 Section 77.1913 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Shaft Sinking § 77.1913 Fire-resistant wood. Except for crossties, timbers, and other wood products...

  19. 30 CFR 77.1913 - Fire-resistant wood.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Fire-resistant wood. 77.1913 Section 77.1913 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Shaft Sinking § 77.1913 Fire-resistant wood. Except for crossties, timbers, and other wood products...

  20. 30 CFR 77.1913 - Fire-resistant wood.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Fire-resistant wood. 77.1913 Section 77.1913 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Shaft Sinking § 77.1913 Fire-resistant wood. Except for crossties, timbers, and other wood products...

  1. Fire and Life Safety Training Needs of Rail Rapid Transit System and Fire Service Personnel

    DOT National Transportation Integrated Search

    1983-05-01

    This report presents a summary and the results of the successful workshop "On Track to Fire and Life Safety in Rail Rapid Transit," held on August 2-4, 1982, at Crystal City, Virginia. Sponsored by the Urban Mass Transportation Administration (UMTA) ...

  2. 29 CFR 1910.39 - Fire prevention plans.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 5 2012-07-01 2012-07-01 false Fire prevention plans. 1910.39 Section 1910.39 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH STANDARDS Exit Routes and Emergency Planning § 1910.39 Fire prevention plans. (a...

  3. 24 CFR 232.620 - Determination of compliance by HHS.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... of Fire Safety Equipment Special Requirements § 232.620 Determination of compliance by HHS. An... the fire safety equipment has been installed, will be in compliance with the HHS requirements for fire... services along with a plan prepared by the applicant for correcting those deficiencies. In such event, HHS...

  4. 24 CFR 232.620 - Determination of compliance by HHS.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... of Fire Safety Equipment Special Requirements § 232.620 Determination of compliance by HHS. An... the fire safety equipment has been installed, will be in compliance with the HHS requirements for fire... services along with a plan prepared by the applicant for correcting those deficiencies. In such event, HHS...

  5. 30 CFR 77.1913 - Fire-resistant wood.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Fire-resistant wood. 77.1913 Section 77.1913 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Shaft Sinking § 77.1913 Fire-resistant wood. Except for crossties, timbers, and other wood products...

  6. 30 CFR 77.1913 - Fire-resistant wood.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fire-resistant wood. 77.1913 Section 77.1913 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Shaft Sinking § 77.1913 Fire-resistant wood. Except for crossties, timbers, and other wood products...

  7. Progress in Fire Detection and Suppression Technology for Future Space Missions

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Urban, David L.

    2000-01-01

    Fire intervention technology (detection and suppression) is a critical part of the strategy of spacecraft fire safety. This paper reviews the status, trends, and issues in fire intervention, particularly the technology applied to the protection of the International Space Station and future missions beyond Earth orbit. An important contribution to improvements in spacecraft fire safety is the understanding of the behavior of fires in the non-convective (microgravity) environment of Earth-orbiting and planetary-transit spacecraft. A key finding is the strong influence of ventilation flow on flame characteristics, flammability limits and flame suppression in microgravity. Knowledge of these flow effects will aid the development of effective processes for fire response and technology for fire suppression.

  8. Study of aircraft crashworthiness for fire protection

    NASA Technical Reports Server (NTRS)

    Cominsky, A.

    1981-01-01

    Impact-survivable postcrash fire accidents were surveyed. The data base developed includes foreign and domestic accidents involving airlines and jet aircraft. The emphasis was placed on domestic accidents, airlines, and jet aircraft due principally to availability of information. Only transport category aircraft in commercial service designed under FAR Part 25 were considered. A matrix was prepared to show the relationships between the accident characteristics and the fire fatalities. Typical postcrash fire scenaries were identified. Safety concepts were developed for three engineering categories: cabin interiors - cabin subsystems; power plant - engines and fuel systems; and structural mechanics - primary and secondary structures. The parameters identified for concept evaluation are cost, effectiveness, and societal concerns. Three concepts were selected for design definition and cost and effectiveness analysis: improved fire-resistant seat materials; anti-misting kerosene; and additional cabin emergency exits.

  9. The approach for shortest paths in fire succor based on component GIS technology

    NASA Astrophysics Data System (ADS)

    Han, Jie; Zhao, Yong; Dai, K. W.

    2007-06-01

    Fire safety is an important issue for the national economy and people's living. Efficiency and exactness of fire department succor directly relate to safety of peoples' lives and property. Many disadvantages of the traditional fire system have been emerged in practical applications. The preparation of pumpers is guided by wireless communication or wire communication, so its real-time and accurate performances are much poorer. The information about the reported fire, such as the position, disaster and map, et al., for alarm and command was processed by persons, which slows the reaction speed and delays the combat opportunity. In order to solve these disadvantages, it has an important role to construct a modern fire command center based on high technology. The construction of modern fire command center can realize the modernization and automation of fire command and management. It will play a great role in protecting safety of peoples' lives and property. The center can enhance battle ability and can reduce the direct and indirect loss of fire damage at most. With the development of science technology, Geographic Information System (GIS) has becoming a new information industry for hardware production, software development, data collection, space analysis and counseling. With the popularization of computers and the development of GIS, GIS has gained increasing broad applications for its strong functionality. Network analysis is one of the most important functions of GIS, and the most elementary and pivotal issue of network analysis is the calculation of shortest paths. The shortest paths are mostly applied to some emergent systems such as 119 fire alarms. These systems mainly require that the computation time of the optimal path should be 1-3 seconds. And during traveling, the next running path of the vehicles should be calculated in time. So the implement of the shortest paths must have a high efficiency. In this paper, the component GIS technology was applied to collect and record the data information (such as, the situation of this disaster, map and road status et al) of the reported fire firstly. The ant colony optimization was used to calculate the shortest path of fire succor secondly. The optimization results were sent to the pumpers, which can let pumpers choose the shortest paths intelligently and come to fire position with least time. The programming method for shortest paths is proposed in section 3. There are three parts in this section. The elementary framework of the proposed programming method is presented in part one. The systematic framework of GIS component is described in part two. The ant colony optimization employed is presented in part three. In section 4, a simple application instance was presented to demonstrate the proposed programming method. There are three parts in this section. The distributed Web application based on component GIS was described in part one. The optimization results without traffic constraint were presented in part two. The optimization results with traffic constraint were presented in part three. The contributions of this paper can be summarized as follows. (1) It proposed an effective approach for shortest paths in fire succor based on component GIS technology. This proposed approach can achieve the real-time decisions of shortest paths for fire succor. (2) It applied the ant colony optimization to implement the shortest path decision. The traffic information was considered in the shortest path decision using ant colony optimization. The final application instance suggests that the proposed approach is feasible, correct and valid.

  10. Intumescent coatings with improved properties for high-rise construction

    NASA Astrophysics Data System (ADS)

    Ustinov, Andrey; Zybina, Olga; Tanklevsky, Leonid; Lebedev, Vasily; Andreev, Andrey

    2018-03-01

    The paper overviews the way of creating intumescent fire-protective compositions with improved properties by adding nano-and micro-sized supplements into them. Intumescent paints are inert at low temperatures, and at higher temperatures they expand and degrade to provide a charred layer of low conductivity materials. The modified intumescent paints are able to form a more stable charred layer than the classical paints. The stability of a charred layer is crucial if the fire safety in high-rise construction must be secured, because a weak charred layer will not provide a required fire endurance for steel bearing structures and they will break down in case of fire. The fire-protective properties of modified intumescent paints were estimated using an electrical furnace. Also the way of thermal decomposition of the paints was studied with thermogravimetric analysis. Results show that modified intumescent paints form a charred layer with improved fire-protective properties; it can serve as a thermal barrier for a longer period of time. Thermogravimetric analysis confirms this fact showing that the temperatures of full thermal decay in case of modified paints are higher than those of non-modified paints.

  11. 30 CFR 57.4430 - Surface storage facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....4430 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention... ignition sources to prevent fire or explosion; and (4) Vented or otherwise constructed to prevent...

  12. 30 CFR 57.4360 - Underground alarm systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....4360 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4360 Underground alarm systems. (a) Fire alarm...

  13. 30 CFR 57.4263 - Underground belt conveyors.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....4263 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Equipment § 57.4263 Underground belt conveyors. Fire protection shall be...

  14. 30 CFR 57.4203 - Extinguisher recharging or replacement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 57.4203 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Equipment § 57.4203 Extinguisher recharging or replacement. Fire...

  15. 30 CFR 56.4201 - Inspection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control... following schedules: (1) Fire extinguishers shall be inspected visually at least once a month to determine...

  16. 30 CFR 56.4203 - Extinguisher recharging or replacement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 56.4203 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Equipment § 56.4203 Extinguisher recharging or replacement. Fire...

  17. 30 CFR 57.4201 - Inspection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control... following schedules: (1) Fire extinguishers shall be inspected visually at least once a month to determine...

  18. 30 CFR 57.4200 - General requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Equipment § 57.4200 General requirements. (a) For fighting fires that could endanger...

  19. 30 CFR 56.4430 - Storage facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and... separated from ignition sources to prevent fire or explosion; and (4) Vented or otherwise constructed to...

  20. 30 CFR 56.4200 - General requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Equipment § 56.4200 General requirements. (a) For fighting fires that could endanger...

  1. 30 CFR 56.4104 - Combustible waste.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and... liquids, shall not accumulate in quantities that could create a fire hazard. (b) Until disposed of...

  2. 30 CFR 56.4104 - Combustible waste.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... properly, waste or rags containing flammable or combustible liquids that could create a fire hazard shall... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and...

  3. 30 CFR 56.4104 - Combustible waste.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... properly, waste or rags containing flammable or combustible liquids that could create a fire hazard shall... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and...

  4. 30 CFR 56.4104 - Combustible waste.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... properly, waste or rags containing flammable or combustible liquids that could create a fire hazard shall... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and...

  5. 30 CFR 56.4104 - Combustible waste.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... properly, waste or rags containing flammable or combustible liquids that could create a fire hazard shall... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and...

  6. Fire safety evaluation system for NASA office/laboratory buildings

    NASA Astrophysics Data System (ADS)

    Nelson, H. E.

    1986-11-01

    A fire safety evaluation system for office/laboratory buildings is developed. The system is a life safety grading system. The system scores building construction, hazardous areas, vertical openings, sprinklers, detectors, alarms, interior finish, smoke control, exit systems, compartmentation, and emergency preparedness.

  7. Decision Analysis Model for Passenger-Aircraft Fire Safety with Application to Fire-Blocking of Seats

    DTIC Science & Technology

    1984-04-01

    50] Collision Aeronaves - Boeing 747 PH-BUF de KLI y Boeing N737PA de Pan Amt en los rodeos (Tenerife) el 27 Marzo de 1977, Joint Accident Report...SAMPLE APPLICATION: FIRE-BLOCKING OF SEATS .......................... 24 4.1 Expected Losses and Savings with Seat Blocking ................... 26 4.2...analyzed to examine the sensitivity of the results on the existing materials. 24 MI ɚ C0 .04 4 0 Cc00 C 0 CU 4’.4 .. c o 90 𔃾.~w - -J 440 c 0 0 cq I04 C.0

  8. Modelling Behaviour of a Carbon Epoxy Composite Exposed to Fire: Part I—Characterisation of Thermophysical Properties

    PubMed Central

    Tranchard, Pauline; Samyn, Fabienne; Duquesne, Sophie; Estèbe, Bruno; Bourbigot, Serge

    2017-01-01

    Thermophysical properties of a carbon-reinforced epoxy composite laminate (T700/M21 composite for aircraft structures) were evaluated using different innovative characterisation methods. Thermogravimetric Analysis (TGA), Simultaneous Thermal analysis (STA), Laser Flash analysis (LFA), and Fourier Transform Infrared (FTIR) analysis were used for measuring the thermal decomposition, the specific heat capacity, the anisotropic thermal conductivity of the composite, the heats of decomposition and the specific heat capacity of released gases. It permits to get input data to feed a three-dimensional (3D) model given the temperature profile and the mass loss obtained during well-defined fire scenarios (model presented in Part II of this paper). The measurements were optimised to get accurate data. The data also permit to create a public database on an aeronautical carbon fibre/epoxy composite for fire safety engineering. PMID:28772854

  9. 14 CFR Appendix C to Part 417 - Flight Safety Analysis Methodologies and Products for an Unguided Suborbital Launch Vehicle Flown...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... operator clearly and convincingly demonstrates that an alternative approach provides an equivalent level of... firing times of the stages, fuel flow rates, contributions from the wind weighting safety system employed... each stage of flight. (iv) Thrust as a function of time. (v) Propellant weight as a function of time...

  10. 14 CFR Appendix C to Part 417 - Flight Safety Analysis Methodologies and Products for an Unguided Suborbital Launch Vehicle Flown...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... operator clearly and convincingly demonstrates that an alternative approach provides an equivalent level of... firing times of the stages, fuel flow rates, contributions from the wind weighting safety system employed... each stage of flight. (iv) Thrust as a function of time. (v) Propellant weight as a function of time...

  11. 14 CFR Appendix C to Part 417 - Flight Safety Analysis Methodologies and Products for an Unguided Suborbital Launch Vehicle Flown...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... operator clearly and convincingly demonstrates that an alternative approach provides an equivalent level of... firing times of the stages, fuel flow rates, contributions from the wind weighting safety system employed... each stage of flight. (iv) Thrust as a function of time. (v) Propellant weight as a function of time...

  12. 14 CFR Appendix C to Part 417 - Flight Safety Analysis Methodologies and Products for an Unguided Suborbital Launch Vehicle Flown...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... operator clearly and convincingly demonstrates that an alternative approach provides an equivalent level of... firing times of the stages, fuel flow rates, contributions from the wind weighting safety system employed... each stage of flight. (iv) Thrust as a function of time. (v) Propellant weight as a function of time...

  13. 14 CFR Appendix C to Part 417 - Flight Safety Analysis Methodologies and Products for an Unguided Suborbital Launch Vehicle Flown...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... operator clearly and convincingly demonstrates that an alternative approach provides an equivalent level of... firing times of the stages, fuel flow rates, contributions from the wind weighting safety system employed... each stage of flight. (iv) Thrust as a function of time. (v) Propellant weight as a function of time...

  14. Toward cellulose nanomaterial commercialization: knowledge gap analysis for safety data sheets according to the globally harmonized system

    Treesearch

    Jo Anne Shatkin; Kimberly J. Ong; James D. Ede; Theodore H. Wegner; Michael Goergen

    2016-01-01

    Commercialization of cellulose nanomaterials (CNs) is rapidly advancing, to the benefit of many end-use product sectors, and providing information about the safe manufacturing and handling for CNs is a priority. Safety Data Sheets (SDS) are required for industrially produced materials to communicate information on their potential health, fire, reactivity, and...

  15. Fire fighter fatalities 1998–2001: overview with an emphasis on structure related traumatic fatalities

    PubMed Central

    Hodous, T; Pizatella, T; Braddee, R; Castillo, D

    2004-01-01

    Objective: To review the causes of all fire fighter line-of-duty-deaths from 1998 through 2001, and present recommendations for preventing fatalities within the specific subgroup of structure related events. Methods: Fire fighter fatality data from the United States Fire Administration were reviewed and classified into three main categories of injury. Investigations conducted through the National Institute for Occupational Safety and Health (NIOSH) Fire Fighter Fatality Investigation and Prevention Program provided the basis for the recommendations presented in this paper. Results: During the time period from 1998–2001, there were 410 line-of-duty deaths among fire fighters in the United States, excluding the 343 fire fighters who died at the World Trade Center on 11 September 2001. The 410 fatalities included 191 medical (non-traumatic) deaths (47%), 75 motor vehicle related fatalities (18%), and 144 other traumatic fatalities (35%). The latter group included 68 fatalities that were associated with structures which commonly involved structural collapse, rapid fire progression, and trapped fire fighters. Conclusions: Structural fires pose particular hazards to fire fighters. Additional efforts must be directed to more effectively use what we have learned through the NIOSH investigations and recommendations from published experts in the safety community, consensus standards, and national fire safety organizations to reduce fire fighter fatalities during structural fire fighting. PMID:15314049

  16. Evaluation of detection and response times of fire sensors using an atmospheric monitoring system

    PubMed Central

    Rowland, J.H.; Litton, C.D.; Thomas, R.A.

    2017-01-01

    Atmospheric monitoring systems (AMS) are required when using air from conveyor belt entries to ventilate working sections in U.S. underground coal mines. AMS technology has the potential to increase fire safety mine-wide, but research is needed to determine the detection and response times for fires of a variety of combustible materials. To evaluate the potential of an AMS for fire detection in other areas of a coal mine, a series of full-scale fire experiments were conducted to determine detection and response times from fires of different combustible materials that are found in U.S. underground coal mines, including high- and low-volatility coals, conveyor belts, brattice materials, different types of wood, diesel fuel, and a foam sealant. These experiments were conducted in the Safety Research Coal Mine (SRCM) of the U.S. National Institute for Occupational Safety and Health (NIOSH) located in Pittsburgh, PA, using a commercially available AMS that is typical of current technology. The results showed that through proper selection of sensors and their locations, a mine-wide AMS can provide sufficient early fire warning times and improve the health and safety of miners. PMID:28529442

  17. Evaluation of detection and response times of fire sensors using an atmospheric monitoring system.

    PubMed

    Rowland, J H; Litton, C D; Thomas, R A

    2016-01-01

    Atmospheric monitoring systems (AMS) are required when using air from conveyor belt entries to ventilate working sections in U.S. underground coal mines. AMS technology has the potential to increase fire safety mine-wide, but research is needed to determine the detection and response times for fires of a variety of combustible materials. To evaluate the potential of an AMS for fire detection in other areas of a coal mine, a series of full-scale fire experiments were conducted to determine detection and response times from fires of different combustible materials that are found in U.S. underground coal mines, including high- and low-volatility coals, conveyor belts, brattice materials, different types of wood, diesel fuel, and a foam sealant. These experiments were conducted in the Safety Research Coal Mine (SRCM) of the U.S. National Institute for Occupational Safety and Health (NIOSH) located in Pittsburgh, PA, using a commercially available AMS that is typical of current technology. The results showed that through proper selection of sensors and their locations, a mine-wide AMS can provide sufficient early fire warning times and improve the health and safety of miners.

  18. Risk analysis procedure for post-wildfire natural hazards in British Columbia

    NASA Astrophysics Data System (ADS)

    Jordan, Peter

    2010-05-01

    Following a severe wildfire season in 2003, and several subsequent damaging debris flow and flood events, the British Columbia Forest Service developed a procedure for analysing risks to public safety and infrastructure from such events. At the same time, the Forest Service undertook a research program to determine the extent of post-wildfire hazards, and examine the hydrologic and geomorphic processes contributing to the hazards. The risk analysis procedure follows the Canadian Standards Association decision-making framework for risk management (which in turn is based on international standards). This has several steps: identification of risk, risk analysis and estimation, evaluation of risk tolerability, developing control or mitigation strategies, and acting on these strategies. The Forest Service procedure deals only with the first two steps. The results are passed on to authorities such as the Provincial Emergency Program and local government, who are responsible for evaluating risks, warning residents, and applying mitigation strategies if appropriate. The objective of the procedure is to identify and analyse risks to public safety and infrastructure. The procedure is loosely based on the BAER (burned area emergency response) program in the USA, with some important differences. Our procedure focuses on identifying risks and warning affected parties, not on mitigation activities such as broadcast erosion control measures. Partly this is due to limited staff and financial resources. Also, our procedure is not multi-agency, but is limited to wildfires on provincial forest land; in British Columbia about 95% of forest land is in the publicly-owned provincial forest. Each fire season, wildfires are screened by size and proximity to values at risk such as populated areas. For selected fires, when the fire is largely contained, the procedure begins with an aerial reconnaissance of the fire, and photography with a hand-held camera, which can be used to make a preliminary map of vegetation burn severity if desired. The next steps include mapping catchment boundaries, field traverses to collect data on soil burn severity and water repellency, identification of unstable hillslopes and channels, and inspection of values at risk from hazards such as debris flows or flooding. BARC (burned area reflectance classification) maps based on satellite imagery are prepared for some fires, although these are typically not available for several weeks. Our objective is to make a preliminary risk analysis report available about two weeks after the fire is contained. If high risks to public safety or infrastructure are identified, the risk analysis reports may make recommendations for mitigation measures to be considered; however, acting on these recommendations is the responsibility of local land managers, local government, or landowners. Mitigation measures for some fires have included engineering treatments to reduce the hydrologic impact of logging roads, protective structures such as dykes or berms, and straw mulching to reduce runoff and erosion on severely burned areas. The Terrace Mountain Fire, with burned 9000 hectares in the Okanagan Valley in 2009, is used as an example of the application of the procedure.

  19. Preparedness of fire safety in underground train station: Comparison between train operators in Malaysia with other operators from the developed countries

    NASA Astrophysics Data System (ADS)

    Tajedi, Noor Aqilah A.; Sukor, Nur Sabahiah A.; Ismail, Mohd Ashraf M.; Shamsudin, Shahrul A.

    2017-10-01

    The purpose of this paper is to compare the fire evacuation plan and preparation at the underground train stations in the different countries. The methodology for this study was using the extended questionnaire survey to investigate the Rapid Rail Sdn Bhd, Malaysia's fire safety plan and preparation at the underground train stations. There were four sections in the questionnaire which included (i) background of the respondents, (ii) the details on the train stations, safety instruction and fire evacuation exercises (iii) technical systems, installation and equipment at the underground stations and (iv) procedures and technical changes related to fire safety that had been applied by the operators. Previously, the respondents from the different train operator services in the developed countries had completed the questionnaires. This paper extends the response from the Rapid Rail Sdn Bhd to compare the emergency procedures and preparation for fire event with the developed countries. As a result, this study found that the equipment and facilities that provided at the underground train stations that operated by Rapid Rail are relevant for fire safety procedures and needs. The main advantage for Rapid Rail is the underground stations were designed with two or more entrances/exits that may perform better evacuation compare to one main entrance/exit train stations in the other developed countries.

  20. Safety engineering in handling fuels and lubricants in civil aviation

    NASA Astrophysics Data System (ADS)

    Protoereiskii, Aleksandr Stepanovich

    The book is concerned with methods of improving working conditions, work hygiene, safety engineering, and fire and explosion prevention during the storage and handling of petroleum products at fuel and lubricant storage facilities. The discussion covers methods of protection against static and atmospheric discharges, lightning protection, safety engineering in fuel and lubricant laboratories, and methods of fire prevention and fire extinction. Attention is also given to methods for administering first aid in case of accidents and poisoning.

  1. National Conference on Campus Safety (15th, University of Vermont, Burlington, June 21-26, 1968).

    ERIC Educational Resources Information Center

    Green, Jack N., Ed.

    Presentations made at the fifteenth National Conference on Campus Safety. The following topics are dealt with--(1) Occupational Health on Campus, (2) Teacher Liability in School Accidents, (3) Indoctrinating Students in Fire Safety, (4) Computer Installations Safety and Fire Protection, (5) The Design of Laboratory Buildings, (6) A Uniform System…

  2. 41 CFR 102-80.120 - What analytical and empirical tools should be used to support the life safety equivalency...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... used to support the life safety equivalency evaluation? Analytical and empirical tools, including fire models and grading schedules such as the Fire Safety Evaluation System (Alternative Approaches to Life... empirical tools should be used to support the life safety equivalency evaluation? 102-80.120 Section 102-80...

  3. 41 CFR 102-80.120 - What analytical and empirical tools should be used to support the life safety equivalency...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... used to support the life safety equivalency evaluation? Analytical and empirical tools, including fire models and grading schedules such as the Fire Safety Evaluation System (Alternative Approaches to Life... empirical tools should be used to support the life safety equivalency evaluation? 102-80.120 Section 102-80...

  4. 30 CFR 57.4104 - Combustible waste.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and... liquids, shall not accumulate in quantities that could create a fire hazard. (b) Waste or rags containing...

  5. 30 CFR 57.4503 - Conveyor belt slippage.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and... within confined areas where evacuation would be restricted in the event of a fire resulting from belt...

  6. 30 CFR 57.4260 - Underground self-propelled equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 57.4260 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire... self-propelled equipment is used underground, a fire extinguisher shall be on the equipment. This...

  7. 30 CFR 57.4361 - Underground evacuation drills.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 57.4361 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire...) Involve activation of the fire alarm system; and (3) Include evacuation of all persons from their work...

  8. 30 CFR 57.4261 - Shaft-station waterlines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....4261 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention... located at underground shaft stations and are part of the mine's fire protection system shall have at...

  9. 30 CFR 57.4761 - Underground shops.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and... toxic gases from a fire originating in an underground shop where maintenance work is routinely done on...

  10. 30 CFR 56.4503 - Conveyor belt slippage.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and... confined areas where evacuation would be restricted in the event of a fire resulting from belt-slippage...

  11. 30 CFR 57.4505 - Fuel lines to underground areas.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 57.4505 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire... shotcrete, one-half inch of gunite, or other noncombustible material with equivalent fire protection...

  12. 30 CFR 57.4104 - Combustible waste.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... flammable or combustible liquids that could create a fire hazard shall be placed in the following containers... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and...

  13. 30 CFR 57.4104 - Combustible waste.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... flammable or combustible liquids that could create a fire hazard shall be placed in the following containers... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and...

  14. 30 CFR 57.4104 - Combustible waste.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... flammable or combustible liquids that could create a fire hazard shall be placed in the following containers... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and...

  15. 30 CFR 57.4104 - Combustible waste.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... flammable or combustible liquids that could create a fire hazard shall be placed in the following containers... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and...

  16. Prevention of 3 "never events" in the operating room: fires, gossypiboma, and wrong-site surgery.

    PubMed

    Zahiri, Hamid R; Stromberg, Jeffrey; Skupsky, Hadas; Knepp, Erin K; Folstein, Matthew; Silverman, Ronald; Singh, Devinder

    2011-03-01

    This study sought to identify and provide preventative recommendations for potentially devastating safety violations in the operating room. A Medline database search from 1950 to current using the terms patient safety and operating room was conducted. All topics identified were reviewed. Three patient safety violations with potential for immediate and devastating outcomes were selected for discussion using evidence-based literature. The search identified 2851 articles, 807 of which were directly related to patient safety in the operating room. Topics addressed by these 807 included infectious complications (26%), fires (11%), communication/teamwork (6%), retained foreign objects (3%), safety checklists (1%), and wrong-site surgery (1%). Fires, gossypiboma, and wrong-site surgery were selected for discussion. Although fire, gossypiboma, and wrong-site surgery should be "never events" in the operating room, they continue to persist as 3 common patient safety violations. This study provides the epidemiology, common etiologies, and evidence-based preventative recommendations for each.

  17. 24 CFR 232.515 - Refund of fees.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... FACILITIES Eligibility Requirements-Supplemental Loans To Finance Purchase and Installation of Fire Safety... that the installation of fire safety equipment for the project has been prevented because of...

  18. 24 CFR 232.515 - Refund of fees.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... FACILITIES Eligibility Requirements-Supplemental Loans To Finance Purchase and Installation of Fire Safety... that the installation of fire safety equipment for the project has been prevented because of...

  19. 24 CFR 232.515 - Refund of fees.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... FACILITIES Eligibility Requirements-Supplemental Loans To Finance Purchase and Installation of Fire Safety... that the installation of fire safety equipment for the project has been prevented because of...

  20. School Fire Safety. Bulletin, 1951, No. 13

    ERIC Educational Resources Information Center

    Viles, N. E.

    1951-01-01

    School fires endanger pupils' lives and take annually a heavy toll in school property losses. If not controlled, these potentials may be changed quickly into serious losses. School officials, teachers, parents, and the public have an interest in school fire safety. Because of other interests and a lack of assigned responsibility in this area fire…

  1. 30 CFR 57.4531 - Surface flammable or combustible liquid storage buildings or rooms.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Installation/construction/maintenance § 57.4531 Surface... fire resistance rating of at least one hour; or (2) Equipped with an automatic fire supression system...

  2. 24 CFR 3280.206 - Fireblocking.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.206 Fireblocking. (a... materials: (1) Minimum one inch nominal lumber, 5/16 inch thick gypsum board, or equivalent fire resistive...

  3. 24 CFR 3280.206 - Fireblocking.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.206 Fireblocking. (a... materials: (1) Minimum one inch nominal lumber, 5/16 inch thick gypsum board, or equivalent fire resistive...

  4. 24 CFR 3280.206 - Fireblocking.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.206 Fireblocking. (a... materials: (1) Minimum one inch nominal lumber, 5/16 inch thick gypsum board, or equivalent fire resistive...

  5. 24 CFR 3280.206 - Fireblocking.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.206 Fireblocking. (a... materials: (1) Minimum one inch nominal lumber, 5/16 inch thick gypsum board, or equivalent fire resistive...

  6. 24 CFR 3280.206 - Fireblocking.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.206 Fireblocking. (a... materials: (1) Minimum one inch nominal lumber, 5/16 inch thick gypsum board, or equivalent fire resistive...

  7. NASA technical advances in aircraft occupant safety. [clear air turbulence detectors, fire resistant materials, and crashworthiness

    NASA Technical Reports Server (NTRS)

    Enders, J. H.

    1978-01-01

    NASA's aviation safety technology program examines specific safety problems associated with atmospheric hazards, crash-fire survival, control of aircraft on runways, human factors, terminal area operations hazards, and accident factors simulation. While aircraft occupants are ultimately affected by any of these hazards, their well-being is immediately impacted by three specific events: unexpected turbulence encounters, fire and its effects, and crash impact. NASA research in the application of laser technology to the problem of clear air turbulence detection, the development of fire resistant materials for aircraft construction, and to the improvement of seats and restraint systems to reduce crash injuries are reviewed.

  8. Fire safety practices in the Shuttle and the Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1993-01-01

    The Shuttle reinforces its policy of fire-preventive measures with onboard smoke detectors and Halon 1301 fire extinguishers. The forthcoming Space Station Freedom will have expanded fire protection with photoelectric smoke detectors, radiation flame detectors, and both fixed and portable carbon dioxide fire extinguishers. Many design and operational issues remain to be resolved for Freedom. In particular, the fire-suppression designs must consider the problems of gas leakage in toxic concentrations, alternative systems for single-failure redundancy, and commonality with the corresponding systems of the Freedom international partners. While physical and engineering requirements remain the primary driving forces for spacecraft fire-safety technology, there are, nevertheless, needs and opportunities for the application of microgravity combustion knowledge to improve and optimize the fire-protective systems.

  9. Safety, Health, and Fire Prevention Guide for Hospital Safety Managers

    DTIC Science & Technology

    1993-03-01

    Safety committee S 2-5 Oxygen quality assurance program 0 2-6 Safety and fire prevention library 0 2-7 Safety services to Dental Activities • 2-8...Chapter 2 Safety Management 2-1. Safety policy statement Health Services Command (HSC) Supplement (Suppl) 1 to Army Regulation (AR) 385-10 and the...Management. (b) The medical staff. (c) The nursing service . (d) Logistics. (e) Nutritional care. (f) Preventive medicine. * 2-3 USAEHA TG No. 152 March 1993 (g

  10. Fire!

    ERIC Educational Resources Information Center

    Jones, Rebecca

    1996-01-01

    The number of school fires is up nationwide. This article describes unsafe school conditions, problems with new fire codes, and the factors that contribute to school fires. Installation of sprinkler systems is recommended. A fire-safety checklist is included. (LMI)

  11. 46 CFR 160.135-3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., the term: Commandant means the Chief of the Lifesaving and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety Division, U.S. Coast Guard Stop 7509, 2703 Martin... the position before displacement. SOLAS means the International Convention for the Safety of Life at...

  12. 46 CFR 160.135-3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., the term: Commandant means the Chief of the Lifesaving and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety Division, U.S. Coast Guard Stop 7509, 2703 Martin... the position before displacement. SOLAS means the International Convention for the Safety of Life at...

  13. 49 CFR 192.171 - Compressor stations: Additional safety equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Compressor stations: Additional safety equipment... Pipeline Components § 192.171 Compressor stations: Additional safety equipment. (a) Each compressor station must have adequate fire protection facilities. If fire pumps are a part of these facilities, their...

  14. 30 CFR 57.4501 - Fuel lines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control... stopping the flow of fuel at the source and shall be located and maintained to minimize fire hazards. This...

  15. 30 CFR 57.4533 - Mine opening vicinity.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and... materials; or (b) Constructed to meet a fire resistance rating of no less than one hour; or (c) Provided...

  16. 30 CFR 56.4102 - Spillage and leakage.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and... liquid spillage or leakage shall be removed in a timely manner or controlled to prevent a fire hazard. ...

  17. 30 CFR 57.4363 - Underground evacuation instruction.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 57.4363 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire... and evacuation plans and procedures and fire warning signals in effect at the mine. (b) Whenever a...

  18. 30 CFR 57.4102 - Spillage and leakage.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and... liquid spillage or leakage shall be removed in a timely manner or controlled to prevent a fire hazard. ...

  19. 30 CFR 56.4501 - Fuel lines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control... stopping the flow of fuel at the source and shall be located and maintained to minimize fire hazards. This...

  20. 30 CFR 56.4230 - Self-propelled equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....4230 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Equipment § 56.4230 Self-propelled equipment. (a)(1) Whenever a fire or its effects...

  1. 30 CFR 77.1100 - Fire protection; training and organization.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....1100 Section 77.1100 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF... facilities and equipment shall be provided commensurate with the potential fire hazards at each structure...

  2. Fire Safety Tests for Cesium-Loaded Spherical Resorcinol Formaldehyde Resin: Data Summary Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Dong-Sang; Schweiger, Michael J.; Peterson, Reid A.

    2012-09-01

    A draft safety evaluation of the scenario for spherical resorcinol formaldehyde (SRF) resin fire inside the ion exchange column was performed by the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Fire Safety organization. The result of this draft evaluation suggested a potential change of the fire safety classification for the Cesium Ion Exchange Process System (CXP) emergency elution vessels, equipment, and piping. To resolve this question, the fire properties of the SRF resin were measured by Southwest Research Institute (SwRI) through a subcontract managed by Pacific Northwest National Laboratory (PNNL). The results of initial fire safety tests on themore » SRF resin were documented in a previous report (WTP-RPT-218). The present report summarizes the results of additional tests performed by SwRI on the cesium-loaded SRF resin. The efforts by PNNL were limited to summarizing the test results provided by SwRI into one consolidated data report. The as-received SwRI report is attached to this report in the Appendix A. Where applicable, the precision and bias of each test method, as given by each American Society for Testing and Materials (ASTM) standard procedure, are included and compared with the SwRI test results of the cesium-loaded SRF resin.« less

  3. Home fire safety beliefs and practices in homes of urban older adults.

    PubMed

    Coty, Mary-Beth; McCammon, Colette; Lehna, Carlee; Twyman, Stephanie; Fahey, Erin

    2015-01-01

    The purpose of this study is to examine factors influencing urban older adults and develop a thematic analysis of how these factors affect seniors' home fire safety (HFS) beliefs and practices. This was a focused ethnography using participant observation and semi-structured interviews. Additionally, public housing records, cognitive functioning, and general health status were assessed. Individual interviews were transcribed verbatim using a constant comparative analysis. Eight seniors participated in the study. Two main themes described older adults' HFS while aging in place: the risk associated with the living environment and the journey associated with maintaining independence. All participants experienced HFS challenges such as limited mobility and financial constraints. Participants' general health and cognitive status additionally influenced their ability to maintain HFS. The findings suggest that urban seniors may have diverse HFS environment risks compared with the general population, highlighting the need for older adult focused HFS interventions. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Safe separation distance score: A new metric for evaluating wildland firefighter safety zones using lidar

    Treesearch

    Michael J. Campbell; Philip E. Dennison; Bret W. Butler

    2016-01-01

    Safety zones are areas where firefighters can retreat to in order to avoid bodily harm when threatened by burnover or entrapment from wildland fire. At present, safety zones are primarily designated by firefighting personnel as part of daily fire management activities. Though critical to safety zone assessment, the effectiveness of this approach is inherently limited...

  5. 24 CFR 232.605 - Contract requirements.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Fire Safety Equipment Form of Contract § 232.605 Contract requirements. (a) The contract between the... contract. Either form of contract shall include the cost of fire safety equipment, its installation, and...

  6. 24 CFR 232.605 - Contract requirements.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Fire Safety Equipment Form of Contract § 232.605 Contract requirements. (a) The contract between the... contract. Either form of contract shall include the cost of fire safety equipment, its installation, and...

  7. 24 CFR 232.605 - Contract requirements.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Fire Safety Equipment Form of Contract § 232.605 Contract requirements. (a) The contract between the... contract. Either form of contract shall include the cost of fire safety equipment, its installation, and...

  8. Fight Fire Without Fire Fighters!

    ERIC Educational Resources Information Center

    Peacock, Richard D.

    1977-01-01

    There is a role for the classroom teacher in teaching fire safety. Discusses the inadequacies of present fire prevention programs and provides ten specific steps teachers can take to avoid suffering and death from fire. (Author/RK)

  9. 46 CFR 160.132-3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...), in this subpart, the term: Commandant means the Chief of the Lifesaving and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety Division, U.S. Coast Guard Stop... described. SOLAS means the International Convention for the Safety of Life at Sea, 1974, as amended. [USCG...

  10. 46 CFR 160.151-3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... subpart, the term: Commandant means the Chief of the Lifesaving and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety Division, U.S. Coast Guard Stop 7509...-57. SOLAS means the International Convention for the Safety of Life at Sea, 1974, as amended by the...

  11. 46 CFR 160.132-3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...), in this subpart, the term: Commandant means the Chief of the Lifesaving and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety Division, U.S. Coast Guard Stop... described. SOLAS means the International Convention for the Safety of Life at Sea, 1974, as amended. [USCG...

  12. 46 CFR 160.151-3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... subpart, the term: Commandant means the Chief of the Lifesaving and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety Division, U.S. Coast Guard Stop 7509...-57. SOLAS means the International Convention for the Safety of Life at Sea, 1974, as amended by the...

  13. 46 CFR 160.133-3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Chief of the Lifesaving and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety Division, U.S. Coast Guard Stop 7509, 2703 Martin Luther King Jr. Avenue SE... International Convention for the Safety of Life at Sea, 1974, as amended. [USCG-2010-0048, 76 FR 62983, Oct. 11...

  14. 46 CFR 160.115-3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...), in this subpart, the term: Commandant means the Chief of the Lifesaving and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety Division, U.S. Coast Guard Stop... described. SOLAS means the International Convention for the Safety of Life at Sea, 1974, as amended. [USCG...

  15. 46 CFR 160.115-3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...), in this subpart, the term: Commandant means the Chief of the Lifesaving and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety Division, U.S. Coast Guard Stop... described. SOLAS means the International Convention for the Safety of Life at Sea, 1974, as amended. [USCG...

  16. 49 CFR 192.171 - Compressor stations: Additional safety equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Design of... must have adequate fire protection facilities. If fire pumps are a part of these facilities, their... event of inadequate cooling or lubrication of the unit. (d) Each compressor station gas engine that...

  17. 30 CFR 57.4100 - Smoking and use of open flames.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 57.4100 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire... flammable gases are— (a) Used or transported in a manner that could create a fire hazard; or (b) Stored or...

  18. 30 CFR Appendix I to Subpart C of... - National Consensus Standards

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Subpart C of Part 56 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire... Standards Mine operators seeking further information in the area of fire prevention and control may consult...

  19. 30 CFR 56.4100 - Smoking and use of open flames.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 56.4100 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire... flammable gases are— (a) Used or transported in a manner that could create a fire hazard; or (b) Stored or...

  20. 30 CFR 75.341 - Direct-fired intake air heaters.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 75.341 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.341 Direct-fired intake air heaters. (a) If any system used to heat intake air malfunctions, the heaters affected shall switch...

  1. Safety. Fire Service Certification Series. Unit FSCS-FF-2-80.

    ERIC Educational Resources Information Center

    Pribyl, Paul F.

    This training unit on safety is part of a 17-unit course package written to aid instructors in the development, teaching, and evaluation of fire fighters in the Wisconsin Fire Service Certification Series. The purpose stated for the 4-hour unit is to assist firefighters in understanding the hazards of their profession and some methods of reducing…

  2. 41 CFR 102-80.115 - Is there more than one option for establishing that an equivalent level of safety exists?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., complete sprinkler protection can be expected to prevent flashover in the room of fire origin, limit fire... the times required for egress. If a combination of fire protection systems provides a margin of safety... Contracts and Property Management Federal Property Management Regulations System (Continued) FEDERAL...

  3. 41 CFR 102-80.115 - Is there more than one option for establishing that an equivalent level of safety exists?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., complete sprinkler protection can be expected to prevent flashover in the room of fire origin, limit fire... the times required for egress. If a combination of fire protection systems provides a margin of safety... Contracts and Property Management Federal Property Management Regulations System (Continued) FEDERAL...

  4. 41 CFR 102-80.115 - Is there more than one option for establishing that an equivalent level of safety exists?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., complete sprinkler protection can be expected to prevent flashover in the room of fire origin, limit fire... the times required for egress. If a combination of fire protection systems provides a margin of safety... Contracts and Property Management Federal Property Management Regulations System (Continued) FEDERAL...

  5. 41 CFR 102-80.115 - Is there more than one option for establishing that an equivalent level of safety exists?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., complete sprinkler protection can be expected to prevent flashover in the room of fire origin, limit fire... the times required for egress. If a combination of fire protection systems provides a margin of safety... Contracts and Property Management Federal Property Management Regulations System (Continued) FEDERAL...

  6. Fire Accident Testing Evaluation (FATE)

    NASA Technical Reports Server (NTRS)

    Ross, H. D.; Mell, W.; Pettegrew, R.; Hicks, M.; Urban, D.

    2001-01-01

    By performing parametric experiments both in normal gravity and reduced gravity on the KC-135 aircraft, as well as developing and analyzing related modeling, generality of the interpretation of the experimental findings will be pursued along with direct recommendations for fire safety practices and policies for fire safety on spacecraft and in Martian habitats. This is the principal value of the research.

  7. Fire Prevention and Emergency Procedures. Module SH-05. Safety and Health.

    ERIC Educational Resources Information Center

    Center for Occupational Research and Development, Inc., Waco, TX.

    This student module on fire prevention and emergency procedures is one of 50 modules concerned with job safety and health. This module discusses the chemistry of fire and the methods for extinguishment, along with the steps necessary for emergency action. Following the introduction, 10 objectives (each keyed to a page in the text) the student is…

  8. 38 CFR 17.81 - Contracts for residential treatment services for veterans with alcohol or drug dependence or...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Meet fire safety requirements as follows: (i) The building must meet the requirements in the applicable...) Portable fire extinguishers shall be installed, inspected, and maintained in accordance with NFPA 10... 101. (vi) An annual fire and safety inspection shall be conducted at the halfway house or residential...

  9. 38 CFR 17.81 - Contracts for residential treatment services for veterans with alcohol or drug dependence or...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Meet fire safety requirements as follows: (i) The building must meet the requirements in the applicable...) Portable fire extinguishers shall be installed, inspected, and maintained in accordance with NFPA 10... 101. (vi) An annual fire and safety inspection shall be conducted at the halfway house or residential...

  10. An assessment of the impact of home safety assessments on fires and fire-related injuries: a case study of Cheshire Fire and Rescue Service.

    PubMed

    Arch, B N; Thurston, M N

    2013-06-01

    Deaths and injuries related to fires are largely preventable events. In the UK, a plethora of community-based fire safety initiatives have been introduced over the last 25 years, often led by fire and rescue services, to address this issue. This paper focuses on one such initiative--home safety assessments (HSAs). Cheshire Fire and Rescue Service (in England) implemented a uniquely large-scale HSA intervention. This paper assesses its effectiveness. The impact of HSAs was assessed in relation to three outcomes: accidental dwelling fires (ADFs), ADFs contained and injuries arising from ADFs. A two-period comparison in fire-related rates of incidences in Cheshire between 2002 and 2011 was implemented, using Poisson regression and adjusting for the national temporal trend using a control group comprising the 37 other English non-metropolitan fire-services. Significant reductions were observed in rates of ADFs [incidence rate ratios (IRR): 0.79, 95% confidence interval (CI): 0.74-0.83, P < 0.001, 2002/03-2007/08 versus 2008/09-2010/11] and associated injuries (IRR: 0.49, 95% CI: 0.39-0.60, P < 0.001, 2002/03-2006/07 versus 2007/08-2010/11), but not in the proportion of fires contained to room of origin. There is strong evidence to suggest that the intervention was successful in reducing domestic fires and related injuries.

  11. 24 CFR 232.570 - Endorsement of credit instrument.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... of Fire Safety Equipment Eligible Security Instruments § 232.570 Endorsement of credit instrument.... (c) Statement by the Secretary of Health and Human Services that the fire safety equipment noted in...

  12. 24 CFR 232.570 - Endorsement of credit instrument.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... of Fire Safety Equipment Eligible Security Instruments § 232.570 Endorsement of credit instrument.... (c) Statement by the Secretary of Health and Human Services that the fire safety equipment noted in...

  13. 24 CFR 232.570 - Endorsement of credit instrument.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... of Fire Safety Equipment Eligible Security Instruments § 232.570 Endorsement of credit instrument.... (c) Statement by the Secretary of Health and Human Services that the fire safety equipment noted in...

  14. Modeling and Analysis of Realistic Fire Scenarios in Spacecraft

    NASA Technical Reports Server (NTRS)

    Brooker, J. E.; Dietrich, D. L.; Gokoglu, S. A.; Urban, D. L.; Ruff, G. A.

    2015-01-01

    An accidental fire inside a spacecraft is an unlikely, but very real emergency situation that can easily have dire consequences. While much has been learned over the past 25+ years of dedicated research on flame behavior in microgravity, a quantitative understanding of the initiation, spread, detection and extinguishment of a realistic fire aboard a spacecraft is lacking. Virtually all combustion experiments in microgravity have been small-scale, by necessity (hardware limitations in ground-based facilities and safety concerns in space-based facilities). Large-scale, realistic fire experiments are unlikely for the foreseeable future (unlike in terrestrial situations). Therefore, NASA will have to rely on scale modeling, extrapolation of small-scale experiments and detailed numerical modeling to provide the data necessary for vehicle and safety system design. This paper presents the results of parallel efforts to better model the initiation, spread, detection and extinguishment of fires aboard spacecraft. The first is a detailed numerical model using the freely available Fire Dynamics Simulator (FDS). FDS is a CFD code that numerically solves a large eddy simulation form of the Navier-Stokes equations. FDS provides a detailed treatment of the smoke and energy transport from a fire. The simulations provide a wealth of information, but are computationally intensive and not suitable for parametric studies where the detailed treatment of the mass and energy transport are unnecessary. The second path extends a model previously documented at ICES meetings that attempted to predict maximum survivable fires aboard space-craft. This one-dimensional model implies the heat and mass transfer as well as toxic species production from a fire. These simplifications result in a code that is faster and more suitable for parametric studies (having already been used to help in the hatch design of the Multi-Purpose Crew Vehicle, MPCV).

  15. Expert systems applied to spacecraft fire safety

    NASA Technical Reports Server (NTRS)

    Smith, Richard L.; Kashiwagi, Takashi

    1989-01-01

    Expert systems are problem-solving programs that combine a knowledge base and a reasoning mechanism to simulate a human expert. The development of an expert system to manage fire safety in spacecraft, in particular the NASA Space Station Freedom, is difficult but clearly advantageous in the long-term. Some needs in low-gravity flammability characteristics, ventilating-flow effects, fire detection, fire extinguishment, and decision models, all necessary to establish the knowledge base for an expert system, are discussed.

  16. Wildfires

    MedlinePlus

    ... motels Expand sub-navigation Hotel fire safety tips Marijuana grow & extraction facilities Nightclubs and other assembly occupancies ... Fire behavior research Fire loss and injury research Benefits of home fire sprinklers Expand sub-navigation Environmental ...

  17. Demonstration of Spacecraft Fire Safety Technology

    NASA Technical Reports Server (NTRS)

    Ruff, Gary A.; Urban, David L.

    2012-01-01

    During the Constellation Program, the development of spacecraft fire safety technologies were focused on the immediate questions related to the atmosphere of the habitable volume and implementation of fire detection, suppression, and postfire clean-up systems into the vehicle architectures. One of the difficulties encountered during the trade studies for these systems was the frequent lack of data regarding the performance of a technology, such as a water mist fire suppression system or an optically-based combustion product monitor. Even though a spacecraft fire safety technology development project was being funded, there was insufficient time and funding to address all the issues as they were identified. At the conclusion of the Constellation Program, these knowledge gaps formed the basis for a project proposed to the Advanced Exploration Systems (AES) Program. This project, subsequently funded by the AES Program and in operation since October 2011, has as its cornerstone the development of an experiment to be conducted on an ISS resupply vehicle, such as the European Space Agency (ESA) Automated Transfer Vehicle (ATV) or Orbital Science s Cygnus vehicle after it leaves the ISS and before it enters the atmosphere. The technology development efforts being conducted in this project include continued quantification of low- and partial-gravity maximum oxygen concentrations of spacecraft-relevant materials, development and verification of sensors for fire detection and post-fire monitoring, development of standards for sizing and selecting spacecraft fire suppression systems, and demonstration of post-fire cleanup strategies. The major technology development efforts are identified in this paper but its primary purpose is to describe the spacecraft fire safety demonstration being planned for the reentry vehicle.

  18. Fire and the Design of Educational Buildings. Building Bulletin 7. Sixth Edition.

    ERIC Educational Resources Information Center

    Department of Education and Science, London (England).

    This bulletin offers guidance on English school premises regulations applying to safety protection against fires in the following general areas: means of escape in case of fire; precautionary measures to prevent fire; fire warning systems and fire fighting; fire spreading speed; structures and materials resistant to fires; and damage control. It…

  19. Counting the cost of false alarms.

    PubMed

    2013-05-01

    While fire and rescue service personnel, the Government, those responsible for fire safety in the healthcare sector, the Health and Safety Executive, fire and rescue services, and indeed fire alarm and detection equipment manufacturers, must be pleased that the number of false fire alarms continues to fall, fire services still attended just under 585,000 fires or false alarm incidents across Great Britain in 2011/12. Of this total, 272,000 were actual fires, of which around 24,000 were in premises classified by the Department for Communities and Local Government (DCLG) as 'other buildings', i.e. not 'dwellings', a category that includes healthcare facilities (representing a 4% fall on 2010-2011). HEJ looks behind the statistics, and at the possibility that some fire services could, in future, charge healthcare providers that persistently report incidents that turn out to be false alarms.

  20. Fire Safety Tests for Spherical Resorcinol Formaldehyde Resin: Data Summary Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Dong-Sang; Peterson, Reid A.; Schweiger, Michael J.

    2012-07-30

    A draft safety evaluation of the scenario for spherical resorcinol-formaldehyde (SRF) resin fire inside the ion exchange column was performed by the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Fire Safety organization. The result of this draft evaluation suggested a potential change of the fire safety classification for the Cesium Ion Exchange Process System (CXP) emergency elution vessels, equipment, and piping, which may be overly bounding based on the fire performance data from the manufacturer of the ion exchange resin selected for use at the WTP. To resolve this question, the fire properties of the SRF resin were measuredmore » by Southwest Research Institute (SwRI), following the American Society for Testing and Materials (ASTM) standard procedures, through a subcontract managed by Pacific Northwest National Laboratory (PNNL). For some tests, the ASTM standard procedures were not entirely appropriate or practical for the SRF resin material, so the procedures were modified and deviations from the ASTM standard procedures were noted. This report summarizes the results of fire safety tests performed and reported by SwRI. The efforts by PNNL were limited to summarizing the test results provided by SwRI into one consolidated data report. All as-received SwRI reports are attached to this report in the Appendix. Where applicable, the precision and bias of each test method, as given by each ASTM standard procedure, are included and compared with the SwRI test results of the SRF resin.« less

  1. Reported fire safety and first-aid amenities in Airbnb venues in 16 American cities.

    PubMed

    Kennedy, Hudson R; Jones, Vanya C; Gielen, Andrea

    2018-05-07

    Airbnb helps hosts rent all or part of their home to guests as an alternative to traditional hospitality settings. Airbnb venues are not uniformly regulated across the USA. This study quantified the reported prevalence of fire safety and first-aid amenities in Airbnb venues in the USA. The sample includes 120 691 venues in 16 US cities. Proportions of host-reported smoke and carbon monoxide (CO) detectors, fire extinguishers and first-aid kits were calculated. The proportion of venues that reportedly contained amenities are as follows: smoke detectors 80% (n=96 087), CO detectors 57.5% (n=69 346), fire extinguishers 42% (n=50 884) and first-aid kits 36% (n=43 497). Among this sample of Airbnb venues, safety deficiencies were noted. While most venues had smoke alarms, approximately 1/2 had CO alarms and less than 1/2 reported having a fire extinguishers or first-aid kits. Local and state governments or Airbnb must implement regulations compliant with current National Fire Protection Association fire safety standards. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. 46 CFR 160.076-5 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Definitions. As used in this part: Commandant means the Chief of the Lifesaving and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety Division, U.S. Coast Guard Stop...

  3. 46 CFR 160.076-5 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Definitions. As used in this part: Commandant means the Chief of the Lifesaving and Fire Safety Standards Division, Life Saving and Fire Safety Division: Commandant (CG-ENG-4), U.S. Coast Guard Headquarters, 2100...

  4. 46 CFR 160.076-5 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Definitions. As used in this part: Commandant means the Chief of the Lifesaving and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety Division, U.S. Coast Guard Stop...

  5. Fire Safety Training with Adults Who Are Profoundly Mentally Retarded.

    ERIC Educational Resources Information Center

    Rae, Rosamond; Roll, David

    1985-01-01

    An intensive fire safety training program for profoundly mentally retarded institutionalized persons resulted in a significant decrease in mean evacuation time and gradual substitution of verbal for physical prompts. (CL)

  6. Climate change and wildland firefighter health and safety.

    PubMed

    Withen, Patrick

    2015-02-01

    The author examines how climate change is impacting wildland firefighters. Climate change has made wildland fires more frequent and more intense. The increase in frequency and intensity of fires has pushed the number of fatalities and injuries higher in recent decades. The most common hazards on fires follow the trend of fire in general in that these hazards become more frequent and intense. Burnovers, heat exhaustion, tree hazards, and many other common fire hazards are more likely. The fire suppression agencies are making every effort to improve health and safety on fires by improving communication, weather forecasting, mapping, fire shelters, decision making and more. Despite these efforts, wildfires are becoming ever more hazardous because of climate change and the increasing frequency and intensity of wildfires. © 2015 SAGE Publications.

  7. Total Approach to Fire Safety.

    ERIC Educational Resources Information Center

    Burgener, Edward

    1979-01-01

    A study completed by the fire department of the City of Winnipeg has documented the effectiveness of smoke detectors in reducing fire losses. The entire Winnipeg fire prevention program is described. (MLF)

  8. 29 CFR Appendix A to Subpart L of... - Fire Protection

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the International Fire Service Training Association, the National Fire Protection Association (NFPA-1041), the International Society of Fire Service Instructors and other fire training sources be... planning, and safety practices. It is again suggested that fire service training sources be consulted for...

  9. 42 CFR 482.41 - Condition of participation: Physical environment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...: Life safety from fire. (1) Except as otherwise provided in this section— (i) The hospital must meet the applicable provisions of the 2000 edition of the Life Safety Code of the National Fire Protection Association... Life Safety Code, issued January 14, 2000, for incorporation by reference in accordance with 5 U.S.C...

  10. 42 CFR 482.41 - Condition of participation: Physical environment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...: Life safety from fire. (1) Except as otherwise provided in this section— (i) The hospital must meet the applicable provisions of the 2000 edition of the Life Safety Code of the National Fire Protection Association... Life Safety Code, issued January 14, 2000, for incorporation by reference in accordance with 5 U.S.C...

  11. Efforts to update firefighter safety zone guidelines

    Treesearch

    Bret Butler

    2009-01-01

    One of the most critical decisions made on wildland fires is the identification of suitable safety zones for firefighters during daily fire management operations. To be effective (timely, repeatable, and accurate), these decisions rely on good training and judgment, but also on clear, concise guidelines. This article is a summary of safety zone guidelines and the...

  12. 20 CFR 654.417 - Fire, safety, and first aid.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Fire, safety, and first aid. 654.417 Section..., safety, and first aid. (a) All buildings in which people sleep or eat shall be constructed and maintained...-type water extinguisher. (g) First aid facilities shall be provided and readily accessible for use at...

  13. Maintenance Facilities for Ammunition, Explosives, and Toxics. Design Manual 28.3.

    DTIC Science & Technology

    1981-11-01

    LOADING DOCK RAMP PROTECTION 28.3-2 8. FIRE PROTECTION 28.3-2 9. SECURITY 28.3-2 10. SAFETY 28.3-2 Section 2. GENERAL AMMUNITION MAINTENANCE SHOPS 28.3...protection in accordance with Section 3 1910.23c, Occupatioual Safety and Health Act Standards Manual. 5 8. FIRE PROTECTION. Fire protection for all...Volume 1, and Fire Protection Engineering, NAVFAC DM-8. 9. SECURITY. Maintenance facilities for ammunition, explosives, and I toxics shall be located so

  14. 24 CFR 201.20 - Property improvement loan eligibility.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... preservation of historic structures. (2) Where the proceeds are to be used for a fire safety equipment loan... jurisdiction over the fire safety requirements of health care facilities prior to making application for a loan...

  15. 24 CFR 201.20 - Property improvement loan eligibility.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... preservation of historic structures. (2) Where the proceeds are to be used for a fire safety equipment loan... jurisdiction over the fire safety requirements of health care facilities prior to making application for a loan...

  16. 24 CFR 201.20 - Property improvement loan eligibility.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... preservation of historic structures. (2) Where the proceeds are to be used for a fire safety equipment loan... jurisdiction over the fire safety requirements of health care facilities prior to making application for a loan...

  17. 24 CFR 232.540 - Method of loan payment and amortization period.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Purchase and Installation of Fire Safety Equipment Eligible Security Instruments § 232.540 Method of loan... either 60, 120, or 180 monthly amortization payments. No fire safety loan shall have an amortization...

  18. 24 CFR 232.540 - Method of loan payment and amortization period.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Purchase and Installation of Fire Safety Equipment Eligible Security Instruments § 232.540 Method of loan... either 60, 120, or 180 monthly amortization payments. No fire safety loan shall have an amortization...

  19. 24 CFR 232.540 - Method of loan payment and amortization period.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Purchase and Installation of Fire Safety Equipment Eligible Security Instruments § 232.540 Method of loan... either 60, 120, or 180 monthly amortization payments. No fire safety loan shall have an amortization...

  20. 24 CFR 201.20 - Property improvement loan eligibility.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... preservation of historic structures. (2) Where the proceeds are to be used for a fire safety equipment loan... jurisdiction over the fire safety requirements of health care facilities prior to making application for a loan...

  1. Teaching safety at a summer camp: evaluation of a fire safety curriculum in an urban community setting.

    PubMed

    Chavez, Audrie A; Duzinski, Sarah V; Wheeler, Tareka C; Lawson, Karla A

    2014-09-01

    To evaluate the effectiveness of the Danger Rangers Fire Safety Curriculum in increasing the fire safety knowledge of low-income, minority children in an urban community setting. Data was collected from child participants via teacher/researcher administered pre-, post-, and retention tests. A self-administered questionnaire was collected from parents pre- and post-intervention to assess fire/burn prevention practices. Paired t-tests were conducted to compare pre-, post-, and retention test mean scores by grade group. McNemar's test was used to determine if there was a change in parent-reported prevention practices following the intervention. The first/second grade group and the third grade group scored significantly higher on the post- and retention test as compared to the pre-test (p<0.0001 for all comparisons). There was no significant change in scores for the pre-k/k group after the intervention. There was a significant increase in 2 of 4 parent-reported fire/burn-related prevention practices after the intervention. Fire safety knowledge improved among first to third grade children, but not among pre-kinder and kindergarten children who participated in the intervention. This study also showed that a program targeted towards children and delivered in a classroom setting has the potential to influence familial prevention practices by proxy. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.

  2. Major Losses

    ERIC Educational Resources Information Center

    Kravis, Miles

    2009-01-01

    From 2003 to 2005, fires on school properties cost about $85 million a year. An estimated 14,700 fires required a fire department response: 36 percent were trash fires, 19 percent were fires in open fields, and 43 percent were structural fires. Sometimes, the needs of school security seem to conflict with the requirements of fire safety. In this…

  3. Foam composite structures. [for fire retardant airframe materials

    NASA Technical Reports Server (NTRS)

    Delano, C. B.; Milligan, R. J.

    1976-01-01

    The need to include fire resistant foams into state of the art aircraft interior paneling to increase passenger safety in aircraft fires was studied. Present efforts were directed toward mechanical and fire testing of panels with foam inclusions. Skinned foam filled honeycomb and PBI structural foams were the two constructions investigated with attention being directed toward weight/performance/cost trade-off. All of the new panels demonstrated improved performance in fire and some were lighter weight but not as strong as the presently used paneling. Continued efforts should result in improved paneling for passenger safety. In particular the simple partial filling (fire side) of state-of-the-art honeycomb with fire resistant foams with little sacrifice in weight would result in panels with increased fire resistance. More important may be the retarded rate of toxic gas evolution in the fire due to the protection of the honeycomb by the foam.

  4. Fire safety knowledge and practices among residents of an assisted living facility.

    PubMed

    Jaslow, David; Ufberg, Jacob; Yoon, Russell; McQueen, Clay; Zecher, Derek; Jakubowski, Greg

    2005-01-01

    Assisted living facilities (ALFs) pose unique fire risks to the elderly that may be linked to specific fire safety (FS) practices. To evaluate self-reported FS practices among ALF residents. All residents of a small ALF were surveyed regarding actual and hypothetical FS behaviors, self-perceived fire risk, and FS preparedness. Fifty-eight ALF residents completed the survey. Thirty-three (58%) individuals reported one or more disabilities. Seven (12%) residents ignored the fire alarm and 21 (35%) could not hear it clearly. Sixteen (28%) residents would attempt to locate the source of a fire rather than escape from the building. Only 24 (42%) residents were familiar with the building fire plan. Twenty-three (40%) people surveyed believed that they were not at risk of fire in the study facility. Residents of an ALF may be at increased fire injury risk due to their FS practices and disabilities.

  5. Cockpit emergency safety system

    NASA Astrophysics Data System (ADS)

    Keller, Leo

    2000-06-01

    A comprehensive safety concept is proposed for aircraft's experiencing an incident to the development of fire and smoke in the cockpit. Fire or excessive heat development caused by malfunctioning electrical appliance may produce toxic smoke, may reduce the clear vision to the instrument panel and may cause health-critical respiration conditions. Immediate reaction of the crew, safe respiration conditions and a clear undisturbed view to critical flight information data can be assumed to be the prerequisites for a safe emergency landing. The personal safety equipment of the aircraft has to be effective in supporting the crew to divert the aircraft to an alternate airport in the shortest possible amount of time. Many other elements in the cause-and-effect context of the emergence of fire, such as fire prevention, fire detection, the fire extinguishing concept, systematic redundancy, the wiring concept, the design of the power supplying system and concise emergency checklist procedures are briefly reviewed, because only a comprehensive and complete approach will avoid fatal accidents of complex aircraft in the future.

  6. A case study on the structural assessment of fire damaged building

    NASA Astrophysics Data System (ADS)

    Osman, M. H.; Sarbini, N. N.; Ibrahim, I. S.; Ma, C. K.; Ismail, M.; Mohd, M. F.

    2017-11-01

    This paper presents a case study on the structural assessment of building damaged by fire and discussed on the site investigations and test results prior to determine the existing condition of the building. The building was on fire for about one hour before it was extinguished. In order to ascertain the integrity of the building, a visual inspection was conducted for all elements (truss, beam, column and wall), followed by non-destructive, load and material tests. The load test was conducted to determine the ability of truss to resist service load, while the material test to determine the residual strength of the material. At the end of the investigation, a structural analysis was carried out to determine the new factor of safety by considering the residual strength. The highlighted was on the truss element due to steel behaviour that is hardly been predicted. Meanwhile, reinforced concrete elements (beam, column and wall) were found externally affected and caused its strength to be considered as sufficient for further used of building. The new factor of safety is equal to 2, considered as the minimum calculated value for the truss member. Therefore, this fire damaged building was found safe and can be used for further application.

  7. Consequences of Fire: The Killing Fumes

    MedlinePlus

    ... Electric Vehicles Fire Fighter Safety and Response for Solar Power Systems Fire Fighting Tactics Under Wind Driven ... Protection Devices Development of Fire Mitigations Solutions for PV Systems Installed on Building Roofs - Phase 1 Electric/ ...

  8. Predicting Fire Season Severity in the Pacific Northwest

    Treesearch

    Paul Werth

    2006-01-01

    Projections of fire season severity that integrate historical weather and fire information can be used by fire managers when making decisions about allocating and prioritizing firefighting resources. They enable fire managers to anticipate fire activity and pre-position resources to maximize public and firefighter safety, reduce environmental impacts, and lower...

  9. Physical and Chemical Aspects of Fire Suppression in Extraterrestrial Environments

    NASA Technical Reports Server (NTRS)

    Takahashi, F.; Linteris, G. T.; Katta, V. R.

    2001-01-01

    A fire, whether in a spacecraft or in occupied spaces on extraterrestrial bases, can lead to mission termination or loss of life. While the fire-safety record of US space missions has been excellent, the advent of longer duration missions to Mars, the moon, or aboard the International Space Station (ISS) increases the likelihood of fire events, with more limited mission termination options. The fire safety program of NASA's manned space flight program is based largely upon the principles of controlling the flammability of on-board materials and greatly eliminating sources of ignition. As a result, very little research has been conducted on fire suppression in the microgravity or reduced-gravity environment. The objectives of this study are: to obtain fundamental knowledge of physical and chemical processes of fire suppression, using gravity and oxygen concentration as independent variables to simulate various extraterrestrial environments, including spacecraft and surface bases in Mars and moon missions; to provide rigorous testing of analytical models, which include comprehensive descriptions of combustion and suppression chemistry; and to provide basic research results useful for technological advances in fire safety, including the development of new fire-extinguishing agents and approaches, in the microgravity environment associated with ISS and in the partial-gravity Martian and lunar environments.

  10. 30 CFR 75.1107-7 - Water spray devices; capacity; water supply; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Water spray devices; capacity; water supply; minimum requirements. 75.1107-7 Section 75.1107-7 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...

  11. 30 CFR 75.1107-7 - Water spray devices; capacity; water supply; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Water spray devices; capacity; water supply; minimum requirements. 75.1107-7 Section 75.1107-7 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...

  12. 30 CFR 75.1107-7 - Water spray devices; capacity; water supply; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Water spray devices; capacity; water supply; minimum requirements. 75.1107-7 Section 75.1107-7 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...

  13. 30 CFR 75.1107-7 - Water spray devices; capacity; water supply; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Water spray devices; capacity; water supply; minimum requirements. 75.1107-7 Section 75.1107-7 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...

  14. 48 CFR 2052.235-71 - Safety, health, and fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... performance of the work under this contract to protect the health and safety of its employees and of members... hazards to life and property. The contractor shall comply with all applicable health, safety, and fire... an order stopping all or any part of the work. Thereafter, a start work order for resumption of work...

  15. Findings of a review of spacecraft fire safety needs

    NASA Technical Reports Server (NTRS)

    Apostolakis, G. E.; Catton, I.; Paulos, T.; Paxton, K.; Jones, S.

    1992-01-01

    Discussions from a workshop to guide UCLA and NASA investigators on the state of knowledge and perceived needs in spacecraft fire safety and its risk management are reviewed, for an introduction to an analytical and experimental project in this field. The report summarizes the workshop discussions and includes the visual aids used in the presentations. Probabilistic Safety Assessment (PSA) methods, which are currently not used, would be of great value to the designs and operation of future human-crew spacecraft. Key points in the discussions were the importance of understanding and testing smoldering as a likely fire scenario in space and the need for smoke damage modeling, since many fire-risk models ignore this mechanism and consider only heat damage.

  16. Fire endurance research at the Forest Products Laboratory

    Treesearch

    R. H. White

    1990-01-01

    Fire endurance research activities and facilities at the FPL concern the ability of a wood member or assembly to withstand the effects of fire while acting as a fire barrier and supporting a load. Fire endurance is generally concerned with the post-flashover portion of the fire. The importance of fire endurance in fire safety is reflected in building code requirements...

  17. Community partnership to promote home fire safety in children with special needs.

    PubMed

    Lehna, Carlee; Janes, Erika G; Rengers, Sharon; Graviss, Jackie; Scrivener, Drane; Knabel, Tom; Carver, Elizabeth; Myers, John

    2014-09-01

    Parents of children with special needs are vigilant as their child may have difficulty independently escaping a burning home. The purpose of this study was to evaluate if providing home fire safety information via a digital video disc (DVD) increases families' knowledge, behavior and ability regarding home fire safety. A school based classroom intervention (using a home fire safety DVD) was provided to parents (n=40) of children with and without special needs to improve home fire safety knowledge, behavior and ability. In addition, parents seen at the Kentucky Commission for Children with Special Health Care Needs clinics (n=47) received the same intervention in cohorts of 1-2 children. For both groups, knowledge, and behavior were measured before and after intervention. Repeated measures ANOVA were used to test for differences between groups and over time. Significance was set at p<0.05. No difference in scores between pre- and post-test scores existed between groups (with special needs vs. without special needs, or classroom vs. individualized instruction). However, some differences were noted for some individual survey questions during post-hoc comparisons. Having a smoke alarm in the home (90% vs. 95%, p=0.029) and having a smoke alarm outside of where everyone sleeps (75% vs. 95%, p=0.005) increased over time and was retained. Having a fire escape plan increased at post intervention (58% vs. 79%, p=0.033), but returned to pre levels at follow-up (58%). Perceived knowledge (7.7 vs. 9.3, p<0.001) and ability (8.7 vs. 9.1, p=0.069) increased over time. Parents of children with special needs had a significant increase in knowledge and behavior over those parents of children without special needs. They also perceived having a high fire safety ability. Many of the post-test questions/behaviors (e.g., capable of exiting home during a fire, etc.) were reported at 100%. The intervention was well received, but may not necessarily be needed. Focus for home fire safety may need to look at younger children and smaller families. Parents of special needs children may have had frequent interaction with health care professionals. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.

  18. Halogenated flame retardants: do the fire safety benefits justify the risks?

    PubMed

    Shaw, Susan D; Blum, Arlene; Weber, Roland; Kannan, Kurunthachalam; Rich, David; Lucas, Donald; Koshland, Catherine P; Dobraca, Dina; Hanson, Sarah; Birnbaum, Linda S

    2010-01-01

    Since the 1970s, an increasing number of regulations have expanded the use of brominated and chlorinated flame retardants. Many of these chemicals are now recognized as global contaminants and are associated with adverse health effects in animals and humans, including endocrine and thyroid disruption, immunotoxicity, reproductive toxicity, cancer, and adverse effects on fetal and child development and neurologic function. Some flame retardants such as polybrominated diphenyl ethers (PBDEs) have been banned or voluntarily phased out by manufacturers because of their environmental persistence and toxicity, only to be replaced by other organohalogens of unknown toxicity. Despite restrictions on further production in some countries, consumer products previously treated with banned retardants are still in use and continue to release toxic chemicals into the environment, and the worldwide use of organohalogen retardants continues to increase. This paper examines major uses and known toxic effects of commonly-used organohalogen flame retardants, replacements for those that have been phased out, their combustion by-products, and their effectiveness at reducing fire hazard. Policy and other solutions to maintain fire safety while reducing toxicity are suggested. The major conclusions are: (1) Flammability regulations can cause greater adverse environmental and health impacts than fire safety benefits. (2) The current options for end-of-life disposal of products treated with organohalogens retardants are problematic. (3) Life-cycle analyses evaluating benefits and risks should consider the health and environmental effects of the chemicals, as well as their fire safety impacts. (4) Most fire deaths and most fire injuries result from inhaling carbon monoxide, irritant gases, and soot. The incorporation of organohalogens can increase the yield of these toxic by-products during combustion. (5) Fire-safe cigarettes, fire-safe candles, child-resistant lighters, sprinklers, and smoke detectors can prevent fires without the potential adverse effects of flame retardant chemicals. (6) Alternatives to organohalogen flame retardant chemicals include using less flammable materials, design changes, and safer chemicals. To date, before evaluating their health and environmental impacts, many flame retardant chemicals have been produced and used, resulting in high levels of human exposure. As a growing literature continues to find adverse impacts from such chemicals, a more systematic approach to their regulation is needed. Before implementing new flammability standards, decision-makers should evaluate the potential fire safety benefit versus the health and environmental impacts of the chemicals, materials, or technologies likely to be used to meet the standard. Reducing the use of toxic or untested flame retardant chemicals in consumer products can protect human and animal health and the global environment without compromising fire safety.

  19. Fire safety at home

    MedlinePlus

    ... over the smoke alarm as needed. Using a fire extinguisher can put out a small fire to keep it from getting out of control. Tips for use include: Keep fire extinguishers in handy locations, at least one on ...

  20. 30 CFR 57.4160 - Underground electric substations and liquid storage facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Prohibitions/precautions/housekeeping § 57.4160... noncombustible materials with equivalent fire protection characteristics. ...

  1. 49 CFR 193.2611 - Fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Fire protection. 193.2611 Section 193.2611 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY LIQUEFIED NATURAL GAS FACILITIES...

  2. Compressed natural gas bus safety: a quantitative risk assessment.

    PubMed

    Chamberlain, Samuel; Modarres, Mohammad

    2005-04-01

    This study assesses the fire safety risks associated with compressed natural gas (CNG) vehicle systems, comprising primarily a typical school bus and supporting fuel infrastructure. The study determines the sensitivity of the results to variations in component failure rates and consequences of fire events. The components and subsystems that contribute most to fire safety risk are determined. Finally, the results are compared to fire risks of the present generation of diesel-fueled school buses. Direct computation of the safety risks associated with diesel-powered vehicles is possible because these are mature technologies for which historical performance data are available. Because of limited experience, fatal accident data for CNG bus fleets are minimal. Therefore, this study uses the probabilistic risk assessment (PRA) approach to model and predict fire safety risk of CNG buses. Generic failure data, engineering judgments, and assumptions are used in this study. This study predicts the mean fire fatality risk for typical CNG buses as approximately 0.23 fatalities per 100-million miles for all people involved, including bus passengers. The study estimates mean values of 0.16 fatalities per 100-million miles for bus passengers only. Based on historical data, diesel school bus mean fire fatality risk is 0.091 and 0.0007 per 100-million miles for all people and bus passengers, respectively. One can therefore conclude that CNG buses are more prone to fire fatality risk by 2.5 times that of diesel buses, with the bus passengers being more at risk by over two orders of magnitude. The study estimates a mean fire risk frequency of 2.2 x 10(-5) fatalities/bus per year. The 5% and 95% uncertainty bounds are 9.1 x 10(-6) and 4.0 x 10(-5), respectively. The risk result was found to be affected most by failure rates of pressure relief valves, CNG cylinders, and fuel piping.

  3. Analysis of toxic effluents released from PVC carpet under different fire conditions.

    PubMed

    Stec, A A; Readman, J; Blomqvist, P; Gylestam, D; Karlsson, D; Wojtalewicz, D; Dlugogorski, B Z

    2013-01-01

    A large number of investigations have been reported on minimising the PAH and PCDD/F yields during controlled combustion, such as incineration. This study is an attempt to quantify acute and chronic toxicants including PAH and PCDD/F in conditions relating to unwanted fires. This paper investigates distribution patterns of fire effluents between gas and aerosol phase, and the different particle size-ranges produced under different fire conditions. PVC carpet was selected as the fuel as a precursor for both PAH and PCDD/F. In order to generate fire effluents under controlled fire conditions, the steady-state tube furnace, was chosen as the physical fire model. Fire scenarios included oxidative pyrolysis, well-ventilated and under-ventilated fires. Fire effluent measurements included: carbon monoxide, carbon dioxide, hydrogen chloride, polycyclic aromatic hydrocarbons, chlorinated dibenzo-dioxins and furans and soot. The distribution patterns between gas and particle phase, and the size-ranges of the particles produced in these fires together with their chemical composition is also reported. Significant quantities of respirable submicron particles were detected, together with a range of PAHs. Lower levels of halogenated dioxins were detected in the fire residue compared with those found in other studies. Nevertheless, the findings do have implications for the health and safety of fire and rescue personnel, fire investigators, and other individuals exposed to the residue from unwanted fires. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Fire Safety Technician

    ERIC Educational Resources Information Center

    Moore, Pam

    2007-01-01

    Fire protection is one of the most important considerations in the construction and operation of industrial plants and commercial buildings. Fire insurance rates are determined by fire probability factors, such as the type of construction, ease of transporting personnel, and the quality and quantity of fire protection equipment available. Because…

  5. 30 CFR 75.1107 - Fire suppression devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Provisions] On and after March 30, 1971, fire-suppression devices meeting specifications prescribed by the... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Fire suppression devices. 75.1107 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...

  6. 30 CFR 75.1107 - Fire suppression devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Provisions] On and after March 30, 1971, fire-suppression devices meeting specifications prescribed by the... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Fire suppression devices. 75.1107 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...

  7. 30 CFR 75.1107 - Fire suppression devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Provisions] On and after March 30, 1971, fire-suppression devices meeting specifications prescribed by the... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Fire suppression devices. 75.1107 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...

  8. 30 CFR 75.1107 - Fire suppression devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Provisions] On and after March 30, 1971, fire-suppression devices meeting specifications prescribed by the... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Fire suppression devices. 75.1107 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...

  9. 30 CFR 75.1107 - Fire suppression devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Provisions] On and after March 30, 1971, fire-suppression devices meeting specifications prescribed by the... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fire suppression devices. 75.1107 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...

  10. Analysis of RHIC beam dump pre-fires

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, W.; Ahrens, L.; Fischer, W.

    2011-03-28

    It has been speculated that the beam may cause instability of the RHIC Beam Abort Kickers. In this study, we explore the available data of past beam operations, the device history of key modulator components, and the radiation patterns to examine the correlations. The RHIC beam abort kicker system was designed and built in the 90's. Over last decade, we have made many improvements to bring the RHIC beam abort kicker system to a stable operational state. However, the challenge continues. We present the analysis of the pre-fire, an unrequested discharge of kicker, issues which relates to the RHIC machinemore » safety and operational stability.« less

  11. Spacecraft Fire Safety and Microgravity Combustion Research

    NASA Technical Reports Server (NTRS)

    Tien, James S.; Ferkul, Paul (Technical Monitor)

    2001-01-01

    Fire safety is an important concern in our daily lives and it plays a special role in the human presence in space. In a spacecraft, the outside environment is hostile and the opportunity to escape is small. Rescue missions are difficult and time consuming. As a result, we should avoid the occurrence of fires in spacecraft as much as possible. If a fire occurs, we need to keep it small and under control. This implies that the materials used on board the spacecraft should be screened carefully, all the machines and devices need to be operated without accident, and fire detectors have to function properly. Once a fire is detected, it can be extinguished quickly and the cabin can be cleaned up to restore operation and sustain life.

  12. Fire Protection for Buildings

    ERIC Educational Resources Information Center

    Edmunds, Jane

    1972-01-01

    Reviews attack on fire safety in high rise buildings made by a group of experts representing the iron and steel industry at a recent conference. According to one expert, fire problems are people oriented, which calls for emphasis on fire prevention rather than reliance on fire suppression and for fire pretection to be built into a structure.…

  13. Smoke Alarms for People Who Are Deaf or Hard-of-Hearing

    MedlinePlus

    ... motels Expand sub-navigation Hotel fire safety tips Marijuana grow & extraction facilities Nightclubs and other assembly occupancies ... Fire behavior research Fire loss and injury research Benefits of home fire sprinklers Expand sub-navigation Environmental ...

  14. Application of petrographic examination techniques to the assessment of fire-damaged concrete and masonry structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ingham, Jeremy P., E-mail: inghamjp@halcrow.com

    The number of building fires has doubled over the last 50 years. There has never been a greater need for structures to be assessed for fire damage to ensure safety and enable appropriate repairs to be planned. Fortunately, even after a severe fire, concrete and masonry structures are generally capable of being repaired rather than demolished. By allowing direct examination of microcracking and mineralogical changes, petrographic examination has become widely used to determine the depth of fire damage for reinforced concrete elements. Petrographic examination can also be applied to fire-damaged masonry structures built of materials such as stone, brick andmore » mortar. Petrography can ensure accurate detection of damaged geomaterials, which provides cost savings during building repair and increased safety reassurance. This paper comprises a review of the role of petrography in fire damage assessments, drawing on a range of actual fire damage investigations.« less

  15. Fire Safety of Passenger Trains: A Review of U.S. and Foreign Approaches

    DOT National Transportation Integrated Search

    1993-12-01

    could develop into potentially life-threatening events. Fire safety is an area of particular interest for both : conventional intercity and commuter trains, as well as new alternative high-speed train technologies. These : technologies include steel-...

  16. 24 CFR 232.515 - Refund of fees.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... INSURANCE FOR NURSING HOMES, INTERMEDIATE CARE FACILITIES, BOARD AND CARE HOMES, AND ASSISTED LIVING FACILITIES Eligibility Requirements-Supplemental Loans To Finance Purchase and Installation of Fire Safety... that the installation of fire safety equipment for the project has been prevented because of...

  17. Review of BART "C" Car Fire Safety Characteristics

    DOT National Transportation Integrated Search

    1987-09-01

    The report presents the results of a review of the fire safety characteristics of the prototype BART "C" Car. Initiated in response to a request from the Urban Mass Transportation Administration (UMTA) Region IX Administrator, the review has been str...

  18. Key Problems of Fire Safety Enforcement in Traffic and Communication Centers (TCC)

    NASA Astrophysics Data System (ADS)

    Medyanik, M.; Zosimova, O.

    2017-10-01

    A Traffic and Communication Center (TCC) means facilities designed and used to distribute and redirect flows of humans and motor vehicles while they get serviced and operate. This paper sets forth the basic problems of fire safety enforcement on the TCC, and the causes that slow down human and vehicle traffic speeds. It proposes ways to solve the problems of fire safety enforcement on the TCC, in the Russian Federation and elsewhere. Engineering solutions are proposed for TCC design, with key outlooks of TCC future development as an alternative way to organize access in transportation.

  19. Fire Technology Abstracts, volume 4, issue 1, August, 1981

    NASA Astrophysics Data System (ADS)

    Holtschlag, L. J.; Kuvshinoff, B. W.; Jernigan, J. B.

    This bibliography contains over 400 citations with abstracts addressing various aspects of fire technology. Subjects cover the dynamics of fire, behavior and properties of materials, fire modeling and test burns, fire protection, fire safety, fire service organization, apparatus and equipment, fire prevention, suppression, planning, human behavior, medical problems, codes and standards, hazard identification, safe handling of materials, insurance, economics of loss and prevention, and more.

  20. On the temperature prediction in a fire escape passage

    NASA Astrophysics Data System (ADS)

    Casano, G.; Piva, S.

    2017-11-01

    Fire safety engineering requires a detailed understanding of fire behaviour and of its effects on structures and people. Many factors may condition the fire scenario, as for example, heat transfer between the flame and the boundary structures. Currently advanced numerical codes for the prediction of the fire behaviour are available. However, these solutions often require heavy calculations and long times. In this context analytical solutions can be useful for a fast analysis of simplified schematizations. After that, it is more effective the final utilization of the advanced fire codes. In this contribution, the temperature in a fire escape passage, separated with a thermally resistant wall from a fire room, is analysed. The escape space is included in a building where the neighbouring rooms are at a constant undisturbed temperature. The presence of the neighbouring rooms is considered with an equivalent heat transfer coefficient, in a boundary condition of the third type. An analytical solution is used to predict the temperature distribution during the fire. It allows to obtain useful information on the temperature reached in the escape area in contact with a burning room; it is useful also for a fast choice of the thermal characteristics of a firewall.

Top