Sample records for fire safety evaluation

  1. Progress Report for Student Research: Fire Safety Skills for Mentally Retarded Children.

    ERIC Educational Resources Information Center

    Hayden, Mary F.; Lefcowitz, M. Jack

    A comprehensive fire safety skills program was evaluated with 32 moderately to mildly retarded adolescents. The program used a fire safety program manual and lessons in basic preventive fire skills, fire safety procedures, and fire escape skills. Across-group comparisons indicated differences in performance between males and females. Fire safety…

  2. 41 CFR 102-80.120 - What analytical and empirical tools should be used to support the life safety equivalency...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) FEDERAL MANAGEMENT REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Accident and Fire... used to support the life safety equivalency evaluation? Analytical and empirical tools, including fire models and grading schedules such as the Fire Safety Evaluation System (Alternative Approaches to Life...

  3. 41 CFR 102-80.120 - What analytical and empirical tools should be used to support the life safety equivalency...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) FEDERAL MANAGEMENT REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Accident and Fire... used to support the life safety equivalency evaluation? Analytical and empirical tools, including fire models and grading schedules such as the Fire Safety Evaluation System (Alternative Approaches to Life...

  4. 41 CFR 102-80.120 - What analytical and empirical tools should be used to support the life safety equivalency...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) FEDERAL MANAGEMENT REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Accident and Fire... used to support the life safety equivalency evaluation? Analytical and empirical tools, including fire models and grading schedules such as the Fire Safety Evaluation System (Alternative Approaches to Life...

  5. Fire safety

    Treesearch

    Robert H. White; Mark A. Dietenberger

    1999-01-01

    Fire safety is an important concern in all types of construction. The high level of national concern for fire safety is reflected in limitations and design requirements in building codes. These code requirements are discussed in the context of fire safety design and evaluation in the initial section of this chapter. Since basic data on fire behavior of wood products...

  6. Fire safety of wood construction

    Treesearch

    Robert H. White; Mark A. Dietenberger

    2010-01-01

    Fire safety is an important concern in all types of construction. The high level of national concern for fire safety is reflected in limitations and design requirements in building codes. These code requirements and related fire performance data are discussed in the context of fire safety design and evaluation in the initial section of this chapter. Because basic data...

  7. An evaluation of The Great Escape: can an interactive computer game improve young children's fire safety knowledge and behaviors?

    PubMed

    Morrongiello, Barbara A; Schwebel, David C; Bell, Melissa; Stewart, Julia; Davis, Aaron L

    2012-07-01

    Fire is a leading cause of unintentional injury and, although young children are at particularly increased risk, there are very few evidence-based resources available to teach them fire safety knowledge and behaviors. Using a pre-post randomized design, the current study evaluated the effectiveness of a computer game (The Great Escape) for teaching fire safety information to young children (3.5-6 years). Using behavioral enactment procedures, children's knowledge and behaviors related to fire safety were compared to a control group of children before and after receiving the intervention. The results indicated significant improvements in knowledge and fire safety behaviors in the intervention group but not the control. Using computer games can be an effective way to promote young children's understanding of safety and how to react in different hazardous situations.

  8. 41 CFR 102-80.120 - What analytical and empirical tools should be used to support the life safety equivalency...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... used to support the life safety equivalency evaluation? Analytical and empirical tools, including fire models and grading schedules such as the Fire Safety Evaluation System (Alternative Approaches to Life... empirical tools should be used to support the life safety equivalency evaluation? 102-80.120 Section 102-80...

  9. 41 CFR 102-80.120 - What analytical and empirical tools should be used to support the life safety equivalency...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... used to support the life safety equivalency evaluation? Analytical and empirical tools, including fire models and grading schedules such as the Fire Safety Evaluation System (Alternative Approaches to Life... empirical tools should be used to support the life safety equivalency evaluation? 102-80.120 Section 102-80...

  10. Fire safety evaluation system for NASA office/laboratory buildings

    NASA Astrophysics Data System (ADS)

    Nelson, H. E.

    1986-11-01

    A fire safety evaluation system for office/laboratory buildings is developed. The system is a life safety grading system. The system scores building construction, hazardous areas, vertical openings, sprinklers, detectors, alarms, interior finish, smoke control, exit systems, compartmentation, and emergency preparedness.

  11. Program for developing and implementing a new approach to designing for fire safety in buildings

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The traditional method of providing for fire safety in buildings through reliance on codes and standards that prescribe specific measures to be taken in the design and construction of buildings to minimize the potential for a fire occurring and to protect property and life should a fire occur was evaluated. A new approach to designing for fire safety in buildings is outlined.

  12. Quantitative assessment of building fire risk to life safety.

    PubMed

    Guanquan, Chu; Jinhua, Sun

    2008-06-01

    This article presents a quantitative risk assessment framework for evaluating fire risk to life safety. Fire risk is divided into two parts: probability and corresponding consequence of every fire scenario. The time-dependent event tree technique is used to analyze probable fire scenarios based on the effect of fire protection systems on fire spread and smoke movement. To obtain the variation of occurrence probability with time, Markov chain is combined with a time-dependent event tree for stochastic analysis on the occurrence probability of fire scenarios. To obtain consequences of every fire scenario, some uncertainties are considered in the risk analysis process. When calculating the onset time to untenable conditions, a range of fires are designed based on different fire growth rates, after which uncertainty of onset time to untenable conditions can be characterized by probability distribution. When calculating occupant evacuation time, occupant premovement time is considered as a probability distribution. Consequences of a fire scenario can be evaluated according to probability distribution of evacuation time and onset time of untenable conditions. Then, fire risk to life safety can be evaluated based on occurrence probability and consequences of every fire scenario. To express the risk assessment method in detail, a commercial building is presented as a case study. A discussion compares the assessment result of the case study with fire statistics.

  13. Special report. Revising your fire safety plans.

    PubMed

    1993-12-01

    Every hospital has a fire safety plan, although some fail to update their plans when circumstances change, such as when the facility is refurbished or new fire protection equipment is added, or when new wings bring in additional patients and staff. Others may fail to develop new education programs to heighten staff awareness of what is expected of them during a fire and to train employees to meet those expectations. In this report, we'll examine the new fire safety plans at two Massachusetts hospitals and the revisions they made to address these issues. We'll offer suggestions for effectively evaluating and revising your own fire safety plans.

  14. Bibliography on aircraft fire hazards and safety. Volume 2: Safety. Part 1: Key numbers 1 to 524

    NASA Technical Reports Server (NTRS)

    Pelouch, J. J., Jr. (Compiler); Hacker, P. T. (Compiler)

    1974-01-01

    Bibliographic citations are presented to describe and define aircraft safety methods, equipment, and criteria. Some of the subjects discussed are: (1) fire and explosion suppression using whiffle balls, (2) ultraviolet flame detecting sensors, (3) evaluation of flame arrestor materials for aircraft fuel systems, (4) crash fire prevention system for supersonic commercial aircraft, and (5) fire suppression for aerospace vehicles.

  15. Fire safety in transit systems fault tree analysis

    DOT National Transportation Integrated Search

    1981-09-01

    Fire safety countermeasures applicable to transit vehicles are identified and evaluated. This document contains fault trees which illustrate the sequences of events which may lead to a transit-fire related casualty. A description of the basis for the...

  16. Fire Safety Power. Sixth Grade. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the sixth grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of sixth grade students, its objectives include: (1) developing a comprehensive understanding of fire physics, (2) evaluating electrical hazards and how to respond to those hazards, and (3)…

  17. Fire Safety of Passenger Trains : Phase II : Application of Fire Hazard Analysis Techniques

    DOT National Transportation Integrated Search

    2001-12-01

    On May 12, 1999, the Federal Railroad Administration (FRA) issued regulations for passenger rail equipment safety standards that included small-scale fire tests and performance criteria to evaluate the flammability and smoke characteristics of indivi...

  18. Fire safety of passenger trains. Phase II, Application of fire hazard analysis techniques.

    DOT National Transportation Integrated Search

    2001-12-01

    On May 12, 1999, the Federal Railroad Administration (FRA) issued regulations for passenger rail equipment safety standards that included small-scale fire tests and performance criteria to evaluate the flammability and smoke characteristics of indivi...

  19. Using Modeling and Rehearsal to Teach Fire Safety to Children with Autism

    ERIC Educational Resources Information Center

    Garcia, David; Dukes, Charles; Brady, Michael P.; Scott, Jack; Wilson, Cynthia L.

    2016-01-01

    We evaluated the efficacy of an instructional procedure to teach young children with autism to evacuate settings and notify an adult during a fire alarm. A multiple baseline design across children showed that an intervention that included modeling, rehearsal, and praise was effective in teaching fire safety skills. Safety skills generalized to…

  20. A qualitative evaluation of fire safety education programs for older adults.

    PubMed

    Diekman, Shane T; Stewart, Tamara A; Teh, S Leesia; Ballesteros, Michael F

    2010-03-01

    This article presents a qualitative evaluation of six fire safety education programs for older adults delivered by public fire educators. Our main aims were to explore how these programs are implemented and to determine important factors that may lead to program success, from the perspectives of the public fire educators and the older adults. For each program, we interviewed the public fire educator(s), observed the program in action, and conducted focus groups with older adults attending the program. Analysis revealed three factors that were believed to facilitate program success (established relationships with the older adult community, rapport with older adult audiences, and presentation relevance) as well as three challenges (lack of a standardized curriculum and program implementation strategies, attendance difficulties, and physical limitations due to age). More fire safety education should be developed for older adult populations. For successful programs, public fire educators should address the specific needs of their local older adult community.

  1. Evaluation of critical nuclear power plant electrical cable response to severe thermal fire conditions

    NASA Astrophysics Data System (ADS)

    Taylor, Gabriel James

    The failure of electrical cables exposed to severe thermal fire conditions are a safety concern for operating commercial nuclear power plants (NPPs). The Nuclear Regulatory Commission (NRC) has promoted the use of risk-informed and performance-based methods for fire protection which resulted in a need to develop realistic methods to quantify the risk of fire to NPP safety. Recent electrical cable testing has been conducted to provide empirical data on the failure modes and likelihood of fire-induced damage. This thesis evaluated numerous aspects of the data. Circuit characteristics affecting fire-induced electrical cable failure modes have been evaluated. In addition, thermal failure temperatures corresponding to cable functional failures have been evaluated to develop realistic single point thermal failure thresholds and probability distributions for specific cable insulation types. Finally, the data was used to evaluate the prediction capabilities of a one-dimension conductive heat transfer model used to predict cable failure.

  2. The development of fire evaluation system for detention and correctional occupancies

    NASA Astrophysics Data System (ADS)

    Nelson, H. E.; Shibe, A. J.

    1984-12-01

    A fire safety evaluation system for detention and correctional occupancies was developed. It can be used for determining if a facility has fire safety equivalent to that obtained by meeting the requirement of a given code. The system was calibrated for use with proposed chapters for detention and correctional occupancies of the Life Safety Code (1985). There are separate sets of requirements for each of four use conditions: one for zoned egress, one for zoned impeded egress, one for impeded egress, and one for contained. Within each set, there are two levels of evaluation: one for partially sprinklered and nonsprinklered buildings, and one for totally sprinklered buildings.

  3. Fire Prevention in California's Riverside County Headstart Project: An Evaluation.

    ERIC Educational Resources Information Center

    Folkman, William S.; Taylor, Jean

    Results of evaluation are reported for a safety program devised by Head Start teachers and California Division of Forestry personnel to teach fire prevention education to Head Start children. Chapters describe the place of fire prevention in Head Start and causes of fire starting behavior in children. The Head Start Fire Prevention Kit is also…

  4. Partnership working between the Fire Service and NHS: delivering a cost-saving service to improve the safety of high-risk people.

    PubMed

    Craig, Joyce A; Creegan, Shelagh; Tait, Martin; Dolan, Donna

    2015-04-14

    The Scottish Fire and Rescue Service and NHS Tayside piloted partnership working. A Community Fire Safety Link Worker provided Risk Assessments to adults, identified by community health teams, at high risk of fires, with the aim of reducing fires. An existing evaluation shows the Service developed a culture of 'high trust' between partners and had high client satisfaction. This paper reports on an economic evaluation of the costs and benefits of the Link Worker role. An economic evaluation of the costs and benefits of the Link Worker role was undertaken. Changes in the Risk Assessment score following delivery of the Service were used to estimate the potential fires avoided. These were valued using a national cost of a fire. The estimated cost of delivering the Service was deducted from these savings. The pilot was estimated to save 4.4 fires, equivalent to £286 per client. The estimated cost of delivering the Service was £55 per client, giving net savings of £231 per client. The pilot was cost-saving under all scenarios, with results sensitive to the probability of a fire. We believe this is the first evaluation of Fire Safety Risk Assessments. Partnership working, delivering joint Risk Assessments in the homes of people at high risk of fire, is modelled to be cost saving. Uncertainties in data and small sample are key limitations. Further research is required into the ex ante risk of fire by risk category. Despite these limitations, potential savings identified in this study supports greater adoption of this partnership initiative.

  5. Evaluated community fire safety interventions in the United States: a review of current literature.

    PubMed

    Ta, Van M; Frattaroli, Shannon; Bergen, Gwendolyn; Gielen, Andrea Carlson

    2006-06-01

    The purpose of the study was to assess the state of fire prevention research, provide an updated synthesis of evaluated fire prevention programs, and discuss the role of fire fighters and data systems in prevention efforts. The review included all evaluations of U.S. based fire prevention interventions published between January 1998 and September 2004 and any earlier articles about U.S. fire prevention interventions not included in two prior review articles. We retrieved information from each identified study including evaluation findings, involvement of fire service personnel and use of existing data systems. We identified twelve articles: seven reported on smoke alarm interventions, three on multi-faceted programs, and two other programs. Five programs involved fire service personnel in the design, implementation, and/or evaluation, and three used existing data systems. Studies reviewed suggest that canvassing and smoke alarm installations are the most effective means of distributing alarms and increasing the functional status of distributed alarms. The functionality of smoke alarms, an issue noted in earlier reviews, remains a problem. Programs involving partnerships with fire departments have indicated success in preventing fires and deaths, improving smoke alarm ownership and functional status, and improving children's fire safety knowledge. Using existing data systems to target and to evaluate interventions was effective. In the years since prior reviews, some improvements in the rigor of evaluation designs have been made, but there is still a need for high quality evaluations that will inform fire injury prevention efforts.

  6. Evaluation of detection and response times of fire sensors using an atmospheric monitoring system

    PubMed Central

    Rowland, J.H.; Litton, C.D.; Thomas, R.A.

    2017-01-01

    Atmospheric monitoring systems (AMS) are required when using air from conveyor belt entries to ventilate working sections in U.S. underground coal mines. AMS technology has the potential to increase fire safety mine-wide, but research is needed to determine the detection and response times for fires of a variety of combustible materials. To evaluate the potential of an AMS for fire detection in other areas of a coal mine, a series of full-scale fire experiments were conducted to determine detection and response times from fires of different combustible materials that are found in U.S. underground coal mines, including high- and low-volatility coals, conveyor belts, brattice materials, different types of wood, diesel fuel, and a foam sealant. These experiments were conducted in the Safety Research Coal Mine (SRCM) of the U.S. National Institute for Occupational Safety and Health (NIOSH) located in Pittsburgh, PA, using a commercially available AMS that is typical of current technology. The results showed that through proper selection of sensors and their locations, a mine-wide AMS can provide sufficient early fire warning times and improve the health and safety of miners. PMID:28529442

  7. Evaluation of detection and response times of fire sensors using an atmospheric monitoring system.

    PubMed

    Rowland, J H; Litton, C D; Thomas, R A

    2016-01-01

    Atmospheric monitoring systems (AMS) are required when using air from conveyor belt entries to ventilate working sections in U.S. underground coal mines. AMS technology has the potential to increase fire safety mine-wide, but research is needed to determine the detection and response times for fires of a variety of combustible materials. To evaluate the potential of an AMS for fire detection in other areas of a coal mine, a series of full-scale fire experiments were conducted to determine detection and response times from fires of different combustible materials that are found in U.S. underground coal mines, including high- and low-volatility coals, conveyor belts, brattice materials, different types of wood, diesel fuel, and a foam sealant. These experiments were conducted in the Safety Research Coal Mine (SRCM) of the U.S. National Institute for Occupational Safety and Health (NIOSH) located in Pittsburgh, PA, using a commercially available AMS that is typical of current technology. The results showed that through proper selection of sensors and their locations, a mine-wide AMS can provide sufficient early fire warning times and improve the health and safety of miners.

  8. Safety. Fire Service Certification Series. Unit FSCS-FF-2-80.

    ERIC Educational Resources Information Center

    Pribyl, Paul F.

    This training unit on safety is part of a 17-unit course package written to aid instructors in the development, teaching, and evaluation of fire fighters in the Wisconsin Fire Service Certification Series. The purpose stated for the 4-hour unit is to assist firefighters in understanding the hazards of their profession and some methods of reducing…

  9. Fire Accident Testing Evaluation (FATE)

    NASA Technical Reports Server (NTRS)

    Ross, H. D.; Mell, W.; Pettegrew, R.; Hicks, M.; Urban, D.

    2001-01-01

    By performing parametric experiments both in normal gravity and reduced gravity on the KC-135 aircraft, as well as developing and analyzing related modeling, generality of the interpretation of the experimental findings will be pursued along with direct recommendations for fire safety practices and policies for fire safety on spacecraft and in Martian habitats. This is the principal value of the research.

  10. Safe separation distance score: A new metric for evaluating wildland firefighter safety zones using lidar

    Treesearch

    Michael J. Campbell; Philip E. Dennison; Bret W. Butler

    2016-01-01

    Safety zones are areas where firefighters can retreat to in order to avoid bodily harm when threatened by burnover or entrapment from wildland fire. At present, safety zones are primarily designated by firefighting personnel as part of daily fire management activities. Though critical to safety zone assessment, the effectiveness of this approach is inherently limited...

  11. Fire Safety Tests for Cesium-Loaded Spherical Resorcinol Formaldehyde Resin: Data Summary Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Dong-Sang; Schweiger, Michael J.; Peterson, Reid A.

    2012-09-01

    A draft safety evaluation of the scenario for spherical resorcinol formaldehyde (SRF) resin fire inside the ion exchange column was performed by the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Fire Safety organization. The result of this draft evaluation suggested a potential change of the fire safety classification for the Cesium Ion Exchange Process System (CXP) emergency elution vessels, equipment, and piping. To resolve this question, the fire properties of the SRF resin were measured by Southwest Research Institute (SwRI) through a subcontract managed by Pacific Northwest National Laboratory (PNNL). The results of initial fire safety tests on themore » SRF resin were documented in a previous report (WTP-RPT-218). The present report summarizes the results of additional tests performed by SwRI on the cesium-loaded SRF resin. The efforts by PNNL were limited to summarizing the test results provided by SwRI into one consolidated data report. The as-received SwRI report is attached to this report in the Appendix A. Where applicable, the precision and bias of each test method, as given by each American Society for Testing and Materials (ASTM) standard procedure, are included and compared with the SwRI test results of the cesium-loaded SRF resin.« less

  12. Health hazard evaluation report HETA 98-0152-2729, Wolfeboro Public Safety Building, Wolfeboro, New Hampshire

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sylvain, D.; Echt, A.

    On March 17, 1998, the National Institute for Occupational Safety and Health (NIOSH) received a Health Hazard Evaluation request (HHE) from the New Hampshire Department of Labor to conduct an evaluation of diesel exhaust exposure at the Wolfeboro Public Safety Building, in Wolfeboro, New Hampshire. The request indicated that Fire and Police personnel were exposed to diesel exhaust from fire apparatus. Asthmatic bronchitis was listed as a health problem resulting from this exposure. On June 23, 1998, NIOSH investigators, accompanied by an industrial hygienist from the New Hampshire Bureau of Health Risk Assessment, conducted an industrial hygiene evaluation at themore » Wolfeboro Public Safety Building.« less

  13. Using modeling and rehearsal to teach fire safety to children with autism.

    PubMed

    Garcia, David; Dukes, Charles; Brady, Michael P; Scott, Jack; Wilson, Cynthia L

    2016-09-01

    We evaluated the efficacy of an instructional procedure to teach young children with autism to evacuate settings and notify an adult during a fire alarm. A multiple baseline design across children showed that an intervention that included modeling, rehearsal, and praise was effective in teaching fire safety skills. Safety skills generalized to novel settings and maintained during a 5-week follow-up in both training and generalization settings. © 2016 Society for the Experimental Analysis of Behavior.

  14. Development of a hazard-based method for evaluating the fire safety of passenger trains

    DOT National Transportation Integrated Search

    1999-01-01

    The fire safety of U.S. passenger rail trains currently is addressed through small-scale flammability and smoke emission tests and performance criteria promulgated by the Federal Railroad Administration (FRA). The FRA approach relies heavily on test ...

  15. Fire safety of passenger trains : phase I : material evaluation (cone calorimeter)

    DOT National Transportation Integrated Search

    1999-01-01

    As part of the passenger equipment rulemaking required by Congress, the Federal Railroad Administration (FRA) has proposed that its existing fire safety guidelines be made mandatory. A major conclusion of a FRA-funded 1993 study by the National Insti...

  16. The development of the residential Fire H.E.L.P. tool kit: a resource to protect homebound older adults.

    PubMed

    Diekman, Shane; Huitric, Michele; Netterville, Linda

    2010-01-01

    This article describes the development of the Fire H.E.L.P. tool kit for training selected Meals On Wheels (MOW) staff in Texas to implement a fire safety program for homebound older adults. We used a formative evaluation approach during the tool kit's development, testing, and initial implementation stages. The tool kit includes instructional curricula on how to implement Fire H.E.L.P., a home assessment tool to determine a residence's smoke alarm needs, and fire safety educational materials. During the tool kit's pilot test, MOW participants showed enhanced fire safety knowledge and high levels of confidence about applying their newfound training skills. After the pilot test, MOW staff used the tool kit to conduct local training sessions, provide fire safety education, and install smoke alarms in the homes of older adults. We believe the approach used to develop this tool kit can be applied to education efforts for other, related healthy home topics.

  17. Fire Safety Tests for Spherical Resorcinol Formaldehyde Resin: Data Summary Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Dong-Sang; Peterson, Reid A.; Schweiger, Michael J.

    2012-07-30

    A draft safety evaluation of the scenario for spherical resorcinol-formaldehyde (SRF) resin fire inside the ion exchange column was performed by the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Fire Safety organization. The result of this draft evaluation suggested a potential change of the fire safety classification for the Cesium Ion Exchange Process System (CXP) emergency elution vessels, equipment, and piping, which may be overly bounding based on the fire performance data from the manufacturer of the ion exchange resin selected for use at the WTP. To resolve this question, the fire properties of the SRF resin were measuredmore » by Southwest Research Institute (SwRI), following the American Society for Testing and Materials (ASTM) standard procedures, through a subcontract managed by Pacific Northwest National Laboratory (PNNL). For some tests, the ASTM standard procedures were not entirely appropriate or practical for the SRF resin material, so the procedures were modified and deviations from the ASTM standard procedures were noted. This report summarizes the results of fire safety tests performed and reported by SwRI. The efforts by PNNL were limited to summarizing the test results provided by SwRI into one consolidated data report. All as-received SwRI reports are attached to this report in the Appendix. Where applicable, the precision and bias of each test method, as given by each ASTM standard procedure, are included and compared with the SwRI test results of the SRF resin.« less

  18. Teaching safety at a summer camp: evaluation of a fire safety curriculum in an urban community setting.

    PubMed

    Chavez, Audrie A; Duzinski, Sarah V; Wheeler, Tareka C; Lawson, Karla A

    2014-09-01

    To evaluate the effectiveness of the Danger Rangers Fire Safety Curriculum in increasing the fire safety knowledge of low-income, minority children in an urban community setting. Data was collected from child participants via teacher/researcher administered pre-, post-, and retention tests. A self-administered questionnaire was collected from parents pre- and post-intervention to assess fire/burn prevention practices. Paired t-tests were conducted to compare pre-, post-, and retention test mean scores by grade group. McNemar's test was used to determine if there was a change in parent-reported prevention practices following the intervention. The first/second grade group and the third grade group scored significantly higher on the post- and retention test as compared to the pre-test (p<0.0001 for all comparisons). There was no significant change in scores for the pre-k/k group after the intervention. There was a significant increase in 2 of 4 parent-reported fire/burn-related prevention practices after the intervention. Fire safety knowledge improved among first to third grade children, but not among pre-kinder and kindergarten children who participated in the intervention. This study also showed that a program targeted towards children and delivered in a classroom setting has the potential to influence familial prevention practices by proxy. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.

  19. Investment appraisal using quantitative risk analysis.

    PubMed

    Johansson, Henrik

    2002-07-01

    Investment appraisal concerned with investments in fire safety systems is discussed. Particular attention is directed at evaluating, in terms of the Bayesian decision theory, the risk reduction that investment in a fire safety system involves. It is shown how the monetary value of the change from a building design without any specific fire protection system to one including such a system can be estimated by use of quantitative risk analysis, the results of which are expressed in terms of a Risk-adjusted net present value. This represents the intrinsic monetary value of investing in the fire safety system. The method suggested is exemplified by a case study performed in an Avesta Sheffield factory.

  20. Spacecraft fire-safety experiments for space station: Technology development mission

    NASA Technical Reports Server (NTRS)

    Youngblood, Wallace W.

    1988-01-01

    Three concept designs for low-gravity, fire-safety related experiments are presented, as selected for the purpose of addressing key issues of enhancing safety and yet encouraging access to long-duration, manned spacecraft such as the NASA space station. The selected low-gravity experiments are the following: (1) an investigation of the flame-spread rate and combustion-product evolution of the burning of typical thicknesses of spacecraft materials in very low-speed flows; (2) an evaluation of the interaction of fires and candidate extinguishers in various fire scenarios; and (3) an investigation of the persistence and propagation of smoldering and deep-seated combustion. Each experiment is expected to provide fundamental combustion-science data, as well as the fire-safety applications, and each requires the unique long-duration, low-gravity environment of the space station. Two generic test facilities, i.e., the Combustion Tunnel Facility and the Combustion Facility, are proposed for space station accommodation to support the selected experiments. In addition, three near-term, fire-safety related experiments are described along with other related precursor activities.

  1. Evaluation of fire hazard inspection procedures in Butte County, California

    Treesearch

    William S. Folkman

    1967-01-01

    To assess effectiveness of fire hazard inspection procedures in securing compliance with fire safety requirements, effects of different types and combinations of contacts and timing were determined, and the production capacity of inspectors measured. It was demonstrated that fire law inspection is as much fire prevention education and engineering as it is law...

  2. Halogenated flame retardants: do the fire safety benefits justify the risks?

    PubMed

    Shaw, Susan D; Blum, Arlene; Weber, Roland; Kannan, Kurunthachalam; Rich, David; Lucas, Donald; Koshland, Catherine P; Dobraca, Dina; Hanson, Sarah; Birnbaum, Linda S

    2010-01-01

    Since the 1970s, an increasing number of regulations have expanded the use of brominated and chlorinated flame retardants. Many of these chemicals are now recognized as global contaminants and are associated with adverse health effects in animals and humans, including endocrine and thyroid disruption, immunotoxicity, reproductive toxicity, cancer, and adverse effects on fetal and child development and neurologic function. Some flame retardants such as polybrominated diphenyl ethers (PBDEs) have been banned or voluntarily phased out by manufacturers because of their environmental persistence and toxicity, only to be replaced by other organohalogens of unknown toxicity. Despite restrictions on further production in some countries, consumer products previously treated with banned retardants are still in use and continue to release toxic chemicals into the environment, and the worldwide use of organohalogen retardants continues to increase. This paper examines major uses and known toxic effects of commonly-used organohalogen flame retardants, replacements for those that have been phased out, their combustion by-products, and their effectiveness at reducing fire hazard. Policy and other solutions to maintain fire safety while reducing toxicity are suggested. The major conclusions are: (1) Flammability regulations can cause greater adverse environmental and health impacts than fire safety benefits. (2) The current options for end-of-life disposal of products treated with organohalogens retardants are problematic. (3) Life-cycle analyses evaluating benefits and risks should consider the health and environmental effects of the chemicals, as well as their fire safety impacts. (4) Most fire deaths and most fire injuries result from inhaling carbon monoxide, irritant gases, and soot. The incorporation of organohalogens can increase the yield of these toxic by-products during combustion. (5) Fire-safe cigarettes, fire-safe candles, child-resistant lighters, sprinklers, and smoke detectors can prevent fires without the potential adverse effects of flame retardant chemicals. (6) Alternatives to organohalogen flame retardant chemicals include using less flammable materials, design changes, and safer chemicals. To date, before evaluating their health and environmental impacts, many flame retardant chemicals have been produced and used, resulting in high levels of human exposure. As a growing literature continues to find adverse impacts from such chemicals, a more systematic approach to their regulation is needed. Before implementing new flammability standards, decision-makers should evaluate the potential fire safety benefit versus the health and environmental impacts of the chemicals, materials, or technologies likely to be used to meet the standard. Reducing the use of toxic or untested flame retardant chemicals in consumer products can protect human and animal health and the global environment without compromising fire safety.

  3. Massachusetts Public Fire and Safety Education Curriculum Planning Guidebook. Second Version.

    ERIC Educational Resources Information Center

    Massachusetts Department of Fire Services, Stow.

    This updated curriculum planning guidebook is a resource for fire educators throughout the state of Massachusetts. It is designed to be a tool in efforts to: identify fire problems in the community; select appropriate behaviors and lessons to correct the fire problems; design fire education programs; and implement and evaluate the programs. The…

  4. The potential for pulmonary heat injury resulting from the activation of a cabin water spray system to fight aircraft cabin fires.

    DOT National Transportation Integrated Search

    1995-05-01

    A cabin water spray system (CWSS) has been suggested as a means of attenuating the severity of smoke and fire commonly associated with aircraft accidents. All aspects of passenger and cabin safety must be considered when evaluating a new safety syste...

  5. KSC-2011-6637

    NASA Image and Video Library

    2011-08-31

    CAPE CANAVERAL, Fla. -- NASA Fire Rescue personnel assist a volunteer portraying an injured Huey II helicopter crew member participating in the aviation safety exercise during Emergency Response Safety Training at the Shuttle Landing Facility, Runway 33, at NASA’s Kennedy Space Center in Florida. The simulated helicopter mishap exercise was conducted to evaluate emergency response and mishap investigations of aircraft at Kennedy. Participants included Air Rescue Fire Fighters, Flight Operations, Disaster Preparedness, Security, and Safety. NASA mandates simulated aviation safety training take place every two years. Photo credit: NASA/Kim Shiflett

  6. KSC-2011-6644

    NASA Image and Video Library

    2011-08-31

    CAPE CANAVERAL, Fla. -- An ambulance and several NASA Fire Rescue Services vehicles arrive to assist a Huey II helicopter participating in the aviation safety exercise during Emergency Response Safety Training at the Shuttle Landing Facility, Runway 33, at NASA’s Kennedy Space Center in Florida. The simulated helicopter mishap exercise was conducted to evaluate emergency response and mishap investigations of aircraft at Kennedy. Participants included Air Rescue Fire Fighters, Flight Operations, Disaster Preparedness, Security, and Safety. NASA mandates simulated aviation safety training take place every two years. Photo credit: NASA/Kim Shiflett

  7. KSC-2011-6640

    NASA Image and Video Library

    2011-08-31

    CAPE CANAVERAL, Fla. -- NASA Fire Rescue personnel assist volunteers portraying injured Huey II helicopter crew members participating in the aviation safety exercise during Emergency Response Safety Training at the Shuttle Landing Facility, Runway 33, at NASA’s Kennedy Space Center in Florida. The simulated helicopter mishap exercise was conducted to evaluate emergency response and mishap investigations of aircraft at Kennedy. Participants included Air Rescue Fire Fighters, Flight Operations, Disaster Preparedness, Security, and Safety. NASA mandates simulated aviation safety training take place every two years. Photo credit: NASA/Kim Shiflett

  8. KSC-2011-6639

    NASA Image and Video Library

    2011-08-31

    CAPE CANAVERAL, Fla. -- NASA Fire Rescue personnel assist volunteers portraying injured Huey II helicopter crew members participating in the aviation safety exercise during Emergency Response Safety Training at the Shuttle Landing Facility, Runway 33, at NASA’s Kennedy Space Center in Florida. The simulated helicopter mishap exercise was conducted to evaluate emergency response and mishap investigations of aircraft at Kennedy. Participants included Air Rescue Fire Fighters, Flight Operations, Disaster Preparedness, Security, and Safety. NASA mandates simulated aviation safety training take place every two years. Photo credit: NASA/Kim Shiflett

  9. KSC-2011-6634

    NASA Image and Video Library

    2011-08-31

    CAPE CANAVERAL, Fla. -- A NASA Fire Rescue Services vehicle and a Huey II helicopter support the aviation safety exercise during Emergency Response Safety Training at the Shuttle Landing Facility, Runway 33, at NASA’s Kennedy Space Center in Florida. The simulated helicopter mishap exercise was conducted to evaluate emergency response and mishap investigations of aircraft at Kennedy. Participants included Air Rescue Fire Fighters, Flight Operations, Disaster Preparedness, Security, and Safety. NASA mandates simulated aviation safety training take place every two years. Photo credit: NASA/Kim Shiflett

  10. KSC-2011-6638

    NASA Image and Video Library

    2011-08-31

    CAPE CANAVERAL, Fla. -- NASA Fire Rescue personnel assist volunteers portraying injured Huey II helicopter crew members participating in the aviation safety exercise during Emergency Response Safety Training at the Shuttle Landing Facility, Runway 33, at NASA’s Kennedy Space Center in Florida. The simulated helicopter mishap exercise was conducted to evaluate emergency response and mishap investigations of aircraft at Kennedy. Participants included Air Rescue Fire Fighters, Flight Operations, Disaster Preparedness, Security, and Safety. NASA mandates simulated aviation safety training take place every two years. Photo credit: NASA/Kim Shiflett

  11. KSC-2011-6636

    NASA Image and Video Library

    2011-08-31

    CAPE CANAVERAL, Fla. -- A NASA Fire Rescue Services vehicle, ambulance and Huey II helicopter take part in the aviation safety exercise during Emergency Response Safety Training at the Shuttle Landing Facility, Runway 33, at NASA’s Kennedy Space Center in Florida. The simulated helicopter mishap exercise was conducted to evaluate emergency response and mishap investigations of aircraft at Kennedy. Participants included Air Rescue Fire Fighters, Flight Operations, Disaster Preparedness, Security, and Safety. NASA mandates simulated aviation safety training take place every two years. Photo credit: NASA/Kim Shiflett

  12. KSC-2011-6641

    NASA Image and Video Library

    2011-08-31

    CAPE CANAVERAL, Fla. -- NASA Fire Rescue personnel assist volunteers portraying injured Huey II helicopter crew members participating in the aviation safety exercise during Emergency Response Safety Training at the Shuttle Landing Facility, Runway 33, at NASA’s Kennedy Space Center in Florida. The simulated helicopter mishap exercise was conducted to evaluate emergency response and mishap investigations of aircraft at Kennedy. Participants included Air Rescue Fire Fighters, Flight Operations, Disaster Preparedness, Security, and Safety. NASA mandates simulated aviation safety training take place every two years. Photo credit: NASA/Kim Shiflett

  13. KSC-2011-6645

    NASA Image and Video Library

    2011-08-31

    CAPE CANAVERAL, Fla. -- Volunteers portraying injured Huey II helicopter crew members are assisted by NASA Fire Rescue personnel in support of the aviation safety exercise during Emergency Response Safety Training at the Shuttle Landing Facility, Runway 33, at NASA’s Kennedy Space Center in Florida. The simulated helicopter mishap exercise was conducted to evaluate emergency response and mishap investigations of aircraft at Kennedy. Participants included Air Rescue Fire Fighters, Flight Operations, Disaster Preparedness, Security, and Safety. NASA mandates simulated aviation safety training take place every two years. Photo credit: NASA/Kim Shiflett

  14. Evaluating Injury Prevention Programs: The Oklahoma City Smoke Alarm Project.

    ERIC Educational Resources Information Center

    Mallonee, Sue

    2000-01-01

    Illustrates how evaluating the Oklahoma City Smoke Alarm Project increased its success in reducing residential fire-related injuries and deaths. The program distributed and tested smoke alarms in residential dwellings and offered educational materials on fire prevention and safety. Evaluation provided sound data on program processes and outcomes,…

  15. Risks and issues in fire safety on the Space Station

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1993-01-01

    A fire in the inhabited portion of a spacecraft is a greatly feared hazard, but fire protection in space operations is complicated by two factors. First, the spacecraft cabin is an enclosed volume, which limits the resources for fire fighting and the options for crew escape. Second, an orbiting spacecraft experiences a balance of forces, creating a near-zero-gravity (microgravity) environment that profoundly affects the characteristics of fire initiation, spread, and suppression. The current Shuttle Orbiter is protected by a fire-detection and suppression system whose requirements are derived of necessity from accepted terrestrial and aircraft standards. While experience has shown that Shuttle fire safety is adequate, designers recognize that improved systems to respond specifically to microgravity fire characteristics are highly desirable. Innovative technology is particularly advisable for the Space Station, a forthcoming space community with a complex configuration and long-duration orbital missions, in which the effectiveness of current fire-protection systems is unpredictable. The development of risk assessments to evaluate the probabilities and consequences of fire incidents in spacecraft are briefly reviewed. It further discusses the important unresolved issues and needs for improved fire safety in the Space Station, including those of material selection, spacecraft atmospheres, fire detection, fire suppression, and post-fire restoration.

  16. Fire Detector

    NASA Technical Reports Server (NTRS)

    1978-01-01

    An early warning fire detection sensor developed for NASA's Space Shuttle Orbiter is being evaluated as a possible hazard prevention system for mining operations. The incipient Fire Detector represents an advancement over commercially available smoke detectors in that it senses and signals the presence of a fire condition before the appearance of flame and smoke, offering an extra margin of safety.

  17. Can fire safety in hotels be improved? Results from the survey of a panel of experts in Spain.

    PubMed

    Rubio-Romero, Juan Carlos; Márquez-Sierra, Francisco; Suárez-Cebador, Manuel

    2016-06-08

    The hotel industry is an important driver of the European labour market with over 250,000 hotels employing some 2 million people. In Spain, 240 workers were injured by fires in hotels from 2004 to 2008. Fire is considered to be the most important risk in the hotel industry, but the lack of an EU-wide data recording system for hotels makes it difficult to give exact figures for fire events. We analysed the state of fire prevention systems in hotels in Spain with the aim of proposing strategies to improve fire safety. A 10-item questionnaire was administered from 2007 to 2009 to 15 Spanish experts in fire safety. The questions were measured using a Likert scale and classified into 4 sections: current state of installations, influence of establishment characteristics, application of regulations and priority ranking of actions. Descriptive statistics summarized the data and t-tests evaluated the agreement foreach statement in the questionnaire. The statistical analysis showed homogeneity in the responses by the experts in all four categories: current state of fire safety installations, influence of establishment characteristics, application of regulations, and priority of actions. There was consensus among the experts over the necessity to improve the enforcement of regulations and also regarding the existence of an association between the hotel category (in Spain they are ranked using a 1 to 5 "star" rating system) and the level of fire safety; hotels with a higher category had higher levels of safety. There is a need to identify ways to apply fire safety standards to older hotels so that they comply with new regulations, to standardize regulations for different regions and countries, to improve the maintenance of installations and equipment, to increase the effectiveness of inspections conducted by government bodies, and to raise the general awareness of stakeholders involved in hotel fire prevention.

  18. Impacts: NIST Building and Fire Research Laboratory (technical and societal)

    NASA Astrophysics Data System (ADS)

    Raufaste, N. J.

    1993-08-01

    The Building and Fire Research Laboratory (BFRL) of the National Institute of Standards and Technology (NIST) is dedicated to the life cycle quality of constructed facilities. The report describes major effects of BFRL's program on building and fire research. Contents of the document include: structural reliability; nondestructive testing of concrete; structural failure investigations; seismic design and construction standards; rehabilitation codes and standards; alternative refrigerants research; HVAC simulation models; thermal insulation; residential equipment energy efficiency; residential plumbing standards; computer image evaluation of building materials; corrosion-protection for reinforcing steel; prediction of the service lives of building materials; quality of construction materials laboratory testing; roofing standards; simulating fires with computers; fire safety evaluation system; fire investigations; soot formation and evolution; cone calorimeter development; smoke detector standards; standard for the flammability of children's sleepwear; smoldering insulation fires; wood heating safety research; in-place testing of concrete; communication protocols for building automation and control systems; computer simulation of the properties of concrete and other porous materials; cigarette-induced furniture fires; carbon monoxide formation in enclosure fires; halon alternative fire extinguishing agents; turbulent mixing research; materials fire research; furniture flammability testing; standard for the cigarette ignition resistance of mattresses; support of navy firefighter trainer program; and using fire to clean up oil spills.

  19. Experiments to ensure Space Station fire safety - A challenge

    NASA Technical Reports Server (NTRS)

    Youngblood, W. W.; Seiser, K. M.

    1988-01-01

    Three experiments have been formulated in order to address prominent fire safety requirements aboard the NASA Space Shuttle; these experiments are to be conducted as part of a Space Station-based Technology Development Mission for the growth phase of Space Station construction and operation. The experiments are: (1) an investigation of the flame-spread rate and combustion-product evolution in the burning of typical spacecraft materials in low gravity; (2) an evaluation of the interaction of fires and candidate fire extinguishers in low gravity; and (3) an investigation of the persistence and propagation of smoldering and deep-seated combustion in low gravity.

  20. Plutonium Oxide Containment and the Potential for Water-Borne Transport as a Consequence of ARIES Oxide Processing Operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wayne, David Matthew; Rowland, Joel C.

    2015-02-01

    The question of oxide containment during processing and storage has become a primary concern when considering the continued operability of the Plutonium Facility (PF-4) at Los Alamos National Laboratory (LANL). An Evaluation of the Safety of the Situation (ESS), “Potential for Criticality in a Glovebox Due to a Fire” (TA55-ESS-14-002-R2, since revised to R3) first issued in May, 2014 summarizes these concerns: “The safety issue of fire water potentially entering a glovebox is: the potential for the water to accumulate in the bottom of a glovebox and result in an inadvertent criticality due to the presence of fissionable materials inmore » the glovebox locations and the increased reflection and moderation of neutrons from the fire water accumulation.” As a result, the existing documented safety analysis (DSA) was judged inadequate and, while it explicitly considered the potential for criticality resulting from water intrusion into gloveboxes, criticality safety evaluation documents (CSEDs) for the affected locations did not evaluate the potential for fire water intrusion into a glovebox.« less

  1. Fire safety knowledge and practices among residents of an assisted living facility.

    PubMed

    Jaslow, David; Ufberg, Jacob; Yoon, Russell; McQueen, Clay; Zecher, Derek; Jakubowski, Greg

    2005-01-01

    Assisted living facilities (ALFs) pose unique fire risks to the elderly that may be linked to specific fire safety (FS) practices. To evaluate self-reported FS practices among ALF residents. All residents of a small ALF were surveyed regarding actual and hypothetical FS behaviors, self-perceived fire risk, and FS preparedness. Fifty-eight ALF residents completed the survey. Thirty-three (58%) individuals reported one or more disabilities. Seven (12%) residents ignored the fire alarm and 21 (35%) could not hear it clearly. Sixteen (28%) residents would attempt to locate the source of a fire rather than escape from the building. Only 24 (42%) residents were familiar with the building fire plan. Twenty-three (40%) people surveyed believed that they were not at risk of fire in the study facility. Residents of an ALF may be at increased fire injury risk due to their FS practices and disabilities.

  2. KSC-2011-6642

    NASA Image and Video Library

    2011-08-31

    CAPE CANAVERAL, Fla. -- Volunteers, portraying their individual roles, stand beside a NASA Fire Rescue Services vehicle and a Huey II helicopter in support of the aviation safety exercise during Emergency Response Safety Training at the Shuttle Landing Facility, Runway 33, at NASA’s Kennedy Space Center in Florida. The simulated helicopter mishap exercise was conducted to evaluate emergency response and mishap investigations of aircraft at Kennedy. Participants included Air Rescue Fire Fighters, Flight Operations, Disaster Preparedness, Security, and Safety. NASA mandates simulated aviation safety training take place every two years. Photo credit: NASA/Kim Shiflett

  3. Evaluating a smartphone application to improve child passenger safety and fire safety knowledge and behaviour.

    PubMed

    Omaki, Elise; Shields, Wendy C; McDonald, Eileen; Aitken, Mary E; Bishai, David; Case, James; Gielen, Andrea

    2017-02-01

    Although proven measures for reducing injury due to motor vehicle collision and residential fires exist, the number of families properly and consistently using child passenger restraints and smoke alarms remains low. This paper describes the design of the Safety In Seconds (SIS) 2.0 study, which aims to evaluate the impact of a smartphone app on parents' use of child restraints and smoke alarms. SIS is a multisite randomised controlled trial. Participants are parents of children aged 4-7 years who are visiting the Pediatric Emergency Department or Pediatric Trauma Service. Parents are randomised to receive tailored education about child passenger safety or about fire safety via the SIS smartphone app. A baseline and two follow-up surveys at 3 months and 6 months are conducted. Primary outcomes are: (1) having the correct child restraint for the child's age and size; (2) restraining the child in the back seat of the car; (3) buckling the child up for every ride; (4) having the restraint inspected by a child passenger safety technician; (5) having a working smoke alarm on every level of the home; (6) having hard-wired or lithium battery smoke alarms; (7) having and (8) practising a fire escape plan. Finding ways to communicate with parents about child passenger and fire safety continues to be a research priority. This study will contribute to the evidence about how to promote benefits of proper and consistent child restraint and smoke alarm use. NCT02345941; Pre-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  4. A Fire Safety Certification System for Board and Care Operators and Staff. SBIR Phase II: Final Report.

    ERIC Educational Resources Information Center

    Walker, Bonnie L.

    This report describes Phase II of a project which developed a system for delivering fire safety training to board and care providers who serve adults with developmental disabilities. Phase II focused on developing and pilot testing a "train the trainers" workshop for instructors and field testing the provider's workshop. Evaluation of…

  5. Comparison of public safety provider injury rates.

    PubMed

    Suyama, Joe; Rittenberger, Jon C; Patterson, P Daniel; Hostler, David

    2009-01-01

    During normal operations, public safety personnel may become injured, leading them to seek medical care and possible time off. Examining the nature and patterns of injury may help to identify preventive health measures for all public safety personnel and address specific needs of each discipline based on actual risk. Objective. To determine the types and severity of injuries encountered by public safety personnel during routine work conditions within a single urban population. De-identified workers' compensation data for emergency medical services (EMS), fire, and police providers from one urban center between January 1, 2005, and May 31, 2007, were examined. Data included type of injury, severity of injury, and date of event. Severity was categorized as follows: lost time (type 1), medical evaluation (type 2), report only (type 3), restricted duty (type 4), and not reported (type 5). Analysis of variance (ANOVA) and a pairwise t-test between groups with a Bonferroni correction was performed to determine the relative risk of injuries between groups. During the 29-month interval, an average workforce of 850 firefighters, 194 EMS providers, and 850 police officers were employed. A total of 1,295 workers' compensation events were documented, with 243 (18%) reported from EMS, 477 (36%) from fire, and 608 (46%) from police. Type 1 injuries were more common in fire (39%) and police (38%) than EMS (23%). EMS had higher rates of lost work (type 1) and medical evaluations (type 2) than both fire and police. Workers' compensation events common to all bureaus were minor trauma (76%) and exposures to blood-borne pathogens (12%). Minor traumatic injuries, mostly associated with axial musculoskeletal strains and extremity injuries, were responsible for the majority of injuries resulting in missed work. Injuries more common in a specific bureau included motor vehicle crashes and gunshot wounds (police) and cardiovascular disease, burns, and heat illness (fire). Public safety personnel are affected by both profession-specific and non-profession-specific injuries. Overall, EMS has higher rates of missed time and medical evaluations than both fire and police. These data highlight the need to make direct comparisons of various public safety personnel bureaus using a common time interval and locale in order to rationally plan interventions and apply resources.

  6. Social validation and training of emergency fire safety skills for potential injury prevention and life saving.

    PubMed Central

    Jones, R T; Kazdin, A E; Haney, J I

    1981-01-01

    A multifaceted behavioral program designed to teach emergency fire escape procedures to children was evaluated in a multiple-baseline design. Five children were trained to respond correctly to nine home emergency fire situations under simulated conditions. The situations and responses focused upon in training were identified by a social validation procedure involving consultation with several safety agencies, including the direct input of firefighters. Training, carried out in simulated bedrooms at school, resulted in significant improvements in both overt behavior and self-report of fire safety skills. The gains were maintained at a post-check assessment 2 weeks after training had been terminated. The results are discussed in relation both to the importance of social validation of targets and outcomes and the implications for further research in assessing and developing emergency response skills. PMID:7298537

  7. Experimental optimization of the FireFly 600 photovoltaic off-grid system.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyson, William Earl; Orozco, Ron; Ralph, Mark E.

    2003-10-01

    A comprehensive evaluation and experimental optimization of the FireFly{trademark} 600 off-grid photovoltaic system manufactured by Energia Total, Ltd. was conducted at Sandia National Laboratories in May and June of 2001. This evaluation was conducted at the request of the manufacturer and addressed performance of individual system components, overall system functionality and performance, safety concerns, and compliance with applicable codes and standards. A primary goal of the effort was to identify areas for improvement in performance, reliability, and safety. New system test procedures were developed during the effort.

  8. Fire Safety - Multiple Languages

    MedlinePlus

    ... Arabic (العربية) Expand Section Fire Safety at Home - English PDF Fire Safety at Home - العربية (Arabic) PDF ... Bosnian (bosanski) Expand Section Fire Safety at Home - English PDF Fire Safety at Home - bosanski (Bosnian) PDF ...

  9. Safety in the Chemical Laboratory: Fire Safety and Fire Control in the Chemistry Laboratory.

    ERIC Educational Resources Information Center

    Wilbraham, A. C.

    1979-01-01

    Discusses fire safety and fire control in the chemistry laboratory. The combustion process, extinguishing equipment, extinguisher maintenance and location, and fire safety and practices are included. (HM)

  10. Large-Scale Spacecraft Fire Safety Tests

    NASA Technical Reports Server (NTRS)

    Urban, David; Ruff, Gary A.; Ferkul, Paul V.; Olson, Sandra; Fernandez-Pello, A. Carlos; T'ien, James S.; Torero, Jose L.; Cowlard, Adam J.; Rouvreau, Sebastien; Minster, Olivier; hide

    2014-01-01

    An international collaborative program is underway to address open issues in spacecraft fire safety. Because of limited access to long-term low-gravity conditions and the small volume generally allotted for these experiments, there have been relatively few experiments that directly study spacecraft fire safety under low-gravity conditions. Furthermore, none of these experiments have studied sample sizes and environment conditions typical of those expected in a spacecraft fire. The major constraint has been the size of the sample, with prior experiments limited to samples of the order of 10 cm in length and width or smaller. This lack of experimental data forces spacecraft designers to base their designs and safety precautions on 1-g understanding of flame spread, fire detection, and suppression. However, low-gravity combustion research has demonstrated substantial differences in flame behavior in low-gravity. This, combined with the differences caused by the confined spacecraft environment, necessitates practical scale spacecraft fire safety research to mitigate risks for future space missions. To address this issue, a large-scale spacecraft fire experiment is under development by NASA and an international team of investigators. This poster presents the objectives, status, and concept of this collaborative international project (Saffire). The project plan is to conduct fire safety experiments on three sequential flights of an unmanned ISS re-supply spacecraft (the Orbital Cygnus vehicle) after they have completed their delivery of cargo to the ISS and have begun their return journeys to earth. On two flights (Saffire-1 and Saffire-3), the experiment will consist of a flame spread test involving a meter-scale sample ignited in the pressurized volume of the spacecraft and allowed to burn to completion while measurements are made. On one of the flights (Saffire-2), 9 smaller (5 x 30 cm) samples will be tested to evaluate NASAs material flammability screening tests. The first flight (Saffire-1) is scheduled for July 2015 with the other two following at six-month intervals. A computer modeling effort will complement the experimental effort. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew removes the need for strict containment of combustion products. This will facilitate the first examination of fire behavior on a scale that is relevant to spacecraft fire safety and will provide unique data for fire model validation.

  11. Assessment of the impact of dipped guideways on urban rail transit systems: Ventilation and safety requirements

    NASA Technical Reports Server (NTRS)

    1982-01-01

    The ventilation and fire safety requirements for subway tunnels with dipped profiles between stations as compared to subway tunnels with level profiles were evaluated. This evaluation is based upon computer simulations of a train fire emergency condition. Each of the tunnel configurations evaluated was developed from characteristics that are representative of modern transit systems. The results of the study indicate that: (1) The level tunnel system required about 10% more station cooling than dipped tunnel systems in order to meet design requirements; and (2) The emergency ventilation requirements are greater with dipped tunnel systems than with level tunnel systems.

  12. The Blue Dog: evaluation of an interactive software program to teach young children how to interact safely with dogs.

    PubMed

    Schwebel, David C; Morrongiello, Barbara A; Davis, Aaron L; Stewart, Julia; Bell, Melissa

    2012-04-01

    Pre-post-randomized design evaluated The Blue Dog, a dog safety software program. 76 children aged 3.5-6 years completed 3 tasks to evaluate dog safety pre- and postintervention: (a) pictures (recognition of safe/risky behavior), (b) dollhouse (recall of safe behavior via simulated dollhouse scenarios), and (c) live dog (actual behavior with unfamiliar live dog). Following preintervention evaluation, children were randomly assigned to dog or fire safety conditions, each involving 3 weeks of home computer software use. Children using Blue Dog had greater change in recognition of risky dog situations than children learning fire safety. No between-group differences emerged in recall (dollhouse) or engagement (live-dog) in risky behavior. Families enjoyed using the software. Blue Dog taught children knowledge about safe engagement with dogs, but did not influence recall or implementation of safe behaviors. Dog bites represent a significant pediatric injury concern and continued development of effective interventions is needed.

  13. Evaluation of Less-Flammable Insulation Fluids and Fire-Prevention Guidance for Transformers

    NASA Astrophysics Data System (ADS)

    Yamagishi, Akira; Sugawa, Osami

    This paper concerns the definition and evaluation of less-flammable of insulation fluids for transformers. In particular it focuses on the ISO5660 cone calorimeter method, which is widely used as an evaluation method for the less-flammable of solids, and proposes that such method is also valid for quantitative evaluation of the less-flammable of insulating fluids. Quantifying the combustion characteristics of insulation fluids and analyzing the causes of fires can be said to be the first step toward implementing appropriate safety measures that will render electric utility equipment more fire retardant or fireproof in the future.

  14. Establishing Fire Safety Skills Using Behavioral Skills Training

    ERIC Educational Resources Information Center

    Houvouras, Andrew J., IV; Harvey, Mark T.

    2014-01-01

    The use of behavioral skills training (BST) to educate 3 adolescent boys on the risks of lighters and fire setting was evaluated using in situ assessment in a school setting. Two participants had a history of fire setting. After training, all participants adhered to established rules: (a) avoid a deactivated lighter, (b) leave the training area,…

  15. Spacecraft Fire Safety

    NASA Technical Reports Server (NTRS)

    Margle, Janice M. (Editor)

    1987-01-01

    Fire detection, fire standards and testing, fire extinguishment, inerting and atmospheres, fire-related medical science, aircraft fire safety, Space Station safety concerns, microgravity combustion, spacecraft material flammability testing, and metal combustion are among the topics considered.

  16. The three Rs of fire safety, emergency action, and fire prevention planning: promoting safety at the worksite.

    PubMed

    Thompson, Marcella R

    2003-04-01

    Fire safety is of paramount importance for everyone. In many workplaces, the occupational health nurse's scope of practice encompasses safety related activities. Included within this role is the responsibility for fire safety, emergency action, and fire prevention planning. The Three Rs of fire safety, emergency action, and fire prevention plans are rules, responsibilities, and resources. Myriad building and fire safety codes, regulations, and standards exist with which an employer must comply. An employer's responsibility for installing, testing, inspecting, and maintaining fire safety related equipment is extensive. Emergency action and fire prevention planning begins with conducting a detailed physical survey and preparing site maps. It includes making key policy decisions, writing procedures, and training employees in those procedures by practicing and executing site drills. The best resources available for emergency planning are the local fire department and the property insurer. Planning ahead means an efficient emergency response if disaster strikes. It saves lives, limits property damage, and preserves the environment.

  17. The quest for all-purpose plants

    Treesearch

    Susan L. Frommer; David R. Weise

    1995-01-01

    The fire safety of a home in the wildland/urban interface is influenced by several factors-one of which is the presence and proximity of vegetation to the home. Landscaping may either provide a significant barrier to fire spread and thus potentially increase a home's fire safety or favor fire spread and reduce a home's fire safety. However, fire safety of...

  18. Follow-up evaluation of fire hazard inspection procedures...Butte County, California

    Treesearch

    William S. Folkman

    1968-01-01

    A study made in 1966 in Butte County, Calif., to assess the effectiveness of fire hazard inspection procedures was repeated in 1967. Purpose of the inspections is to secure compliance with fire safety requirements. The observed drop in number of violations suggests a carryover effect in 1967 from the first study. In many cases, personal contact was still necessary to...

  19. Federal Aviation Administration Plan for Research, Engineering & Development, 1998.

    DTIC Science & Technology

    1998-02-01

    release rate. • Improved fracture toughness of non-combustible geopolymer composite fire barriers to enable use as interior and secondary composites ...Fire Resistant, Non-Toxic Interior Panels for Evaluation of Heat Release Rate ♦ Improved Fracture Toughness of Non-Combustible Geopolymer Composite ... composites , atmospheric hazards, crash worthiness, fire safety, and forensics capabilities to support accident investigations. Aviation Security R,E&D

  20. Preventing Fire Death and Injury, Conducting a Fire Drill in a Group Home [and] When You Need a Fire Safety Expert. National Fire Safety Certification System. Continuing Education Program. Volume 1, Numbers 1-3.

    ERIC Educational Resources Information Center

    Walker, Bonnie

    Three booklets provide fire safety information for staff of residential facilities serving people with developmental disabilities. Booklets focus on: (1) preventing fire death and injury, (2) conducting a fire drill in a group home, and (3) the role of fire safety experts. The first booklet stresses the elimination of the following dangers:…

  1. 29 CFR Appendix A to Subpart P of... - Model Fire Safety Plan (Non-Mandatory)

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 7 2013-07-01 2013-07-01 false Model Fire Safety Plan (Non-Mandatory) A Appendix A to...—Model Fire Safety Plan (Non-Mandatory) Model Fire Safety Plan Note: This appendix is non-mandatory and provides guidance to assist employers in establishing a Fire Safety Plan as required in § 1915.502. Table...

  2. 29 CFR Appendix A to Subpart P to... - Model Fire Safety Plan (Non-Mandatory)

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 7 2012-07-01 2012-07-01 false Model Fire Safety Plan (Non-Mandatory) A Appendix A to...—Model Fire Safety Plan (Non-Mandatory) Model Fire Safety Plan Note: This appendix is non-mandatory and provides guidance to assist employers in establishing a Fire Safety Plan as required in § 1915.502. Table...

  3. 29 CFR Appendix A to Subpart P of... - Model Fire Safety Plan (Non-Mandatory)

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 7 2014-07-01 2014-07-01 false Model Fire Safety Plan (Non-Mandatory) A Appendix A to...—Model Fire Safety Plan (Non-Mandatory) Model Fire Safety Plan Note: This appendix is non-mandatory and provides guidance to assist employers in establishing a Fire Safety Plan as required in § 1915.502. Table...

  4. The Spacecraft Fire Experiment (Saffire) - Objectives, Development and Status

    NASA Technical Reports Server (NTRS)

    Schoren, William; Ruff, Gary A.; Urban, David L.

    2016-01-01

    Since 2012, the Spacecraft Fire Experiment (Saffire) has been under development by the Spacecraft Fire Safety Demonstration (SFS Demo) project that is funded by NASA's Advanced Exploration Systems Division in the Human Exploration and Operations Mission Directorate. The overall objective of this project is to reduce the uncertainty and risk associated with the design of spacecraft fire safety systems for NASA's exploration missions. This is accomplished by defining, developing, and conducting experiments that address gaps in spacecraft fire safety knowledge and capabilities identified by NASA's Fire Safety System Maturation Team. This paper describes the three Spacecraft Fire Experiments (Saffire-I, -II, and -III) that were developed at NASA-GRC and that will conduct a series of material flammability tests in low-gravity and at length scales that are realistic for a spacecraft fire. The experiments will be conducted in Orbital ATK's Cygnus vehicle after it has unberthed from the International Space Station. The tests will be fully automated with the data downlinked at the conclusion of the test and before the Cygnus vehicle reenters the atmosphere. The objectives of these experiments are to (1) determine how rapidly a large scale fire grows in low-gravity and (2) investigate the low-g flammability limits compared to those obtained in NASA's normal gravity material flammability screening test. The hardware for these experiments has been completed and is awaiting their respective launches, all planned for 2016. This paper will review the objectives of these experiments and how they address several of the knowledge gaps for NASA's exploration missions. The hardware development will be discussed including several novel approaches that were taken for testing and evaluation of these series payloads. The status of the missions and operational status will also be presented.

  5. Fire tests to evaluate the potential fire threat and its effects on HEPA filter integrity in cell ventilation at the Oak Ridge National Laboratory, Building 7920

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hasegawa, H.K.; Staggs, K.J.; Doughty, S.M.

    1992-12-01

    As a result of a DOE (Tiger Team) Technical Safety Appraisal (November 1990) of the Radiochemical Engineering Development Center (REDC), ORNL Building 7920, a number of fire protection concerns were identified. The primary concern was the perceived loss of ventilation system containment due to the thermal destruction and/or breaching of the prefilters and/or high-efficiency particulate air filters (HEPA `s) and the resultant radioactive release to the external environment. The following report describes the results of an extensive fire test program performed by the Fire Research Discipline (FRD) of the Special Projects Division of Lawrence Livermore National Lab (LLNL) and fundedmore » by ORNL to address these concerns. Full scale mock-ups of a REDC hot cell tank pit, adjacent cubicle pit, and associated ventilation system were constructed at LLNL and 13 fire experiments were conducted to specifically answer the questions raised by the Tiger Team. Our primary test plan was to characterize the burning of a catastrophic solvent spill (kerosene) of 40 liters and its effect on the containment ventilation system prefilters and HEPA filters. In conjunction with ORNL and Lockwood Greene we developed a test matrix that assessed the fire performance of the prefilters and HEPA filters; evaluated the fire response of the fiber reinforced plastic (FRP) epoxy ventilation duct work; the response and effectiveness of the fire protection system, the effect of fire in a cubicle on the vessel off-gas (VOG) elbow, and other fire safety questions.« less

  6. Critical safety assurance factors for manned spacecraft - A fire safety perspective

    NASA Technical Reports Server (NTRS)

    Rodney, George A.

    1990-01-01

    Safety assurance factors for manned spacecraft are discussed with a focus on the Space Station Freedom. A hazard scenario is provided to demonstrate a process commonly used by safety engineers and other analysts to identify onboard safety risks. Fire strategies are described, including a review of fire extinguishing agents being considered for the Space Station. Lessons learned about fire safety technology in other areas are also noted. NASA and industry research on fire safety applications is discussed. NASA's approach to ensuring safety for manned spacecraft is addressed in the context of its multidiscipline program.

  7. Fire Safety in Extraterrestrial Environments

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1998-01-01

    Despite rigorous fire-safety policies and practices, fire incidents are possible during lunar and Martian missions. Fire behavior and hence preventive and responsive safety actions in the missions are strongly influenced by the low-gravity environments in flight and on the planetary surfaces. This paper reviews the understanding and key issues of fire safety in the missions, stressing flame spread, fire detection, suppression, and combustion performance of propellants produced from Martian resources.

  8. 77 FR 21595 - Applications and Amendments to Facility Operating Licenses and Combined Licenses Involving...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-10

    ... must be one which, if proven, would entitle the requestor/petitioner to relief. A requestor/ petitioner..., and fire modeling calculations, have been performed to demonstrate that the performance-based... may include engineering evaluations, probabilistic safety assessments, and fire modeling calculations...

  9. 40 CFR 30.18 - Hotel and motel fire safety.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 1 2013-07-01 2013-07-01 false Hotel and motel fire safety. 30.18... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 30.18 Hotel and motel fire safety. The Hotel and Motel Fire Safety Act of 1990 (Public Law 101-391) establishes a number of fire...

  10. 40 CFR 30.18 - Hotel and motel fire safety.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 1 2014-07-01 2014-07-01 false Hotel and motel fire safety. 30.18... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 30.18 Hotel and motel fire safety. The Hotel and Motel Fire Safety Act of 1990 (Public Law 101-391) establishes a number of fire...

  11. 40 CFR 30.18 - Hotel and motel fire safety.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 1 2012-07-01 2012-07-01 false Hotel and motel fire safety. 30.18... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 30.18 Hotel and motel fire safety. The Hotel and Motel Fire Safety Act of 1990 (Public Law 101-391) establishes a number of fire...

  12. 40 CFR 30.18 - Hotel and motel fire safety.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 1 2011-07-01 2011-07-01 false Hotel and motel fire safety. 30.18... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 30.18 Hotel and motel fire safety. The Hotel and Motel Fire Safety Act of 1990 (Public Law 101-391) establishes a number of fire...

  13. 40 CFR 30.18 - Hotel and motel fire safety.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Hotel and motel fire safety. 30.18... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 30.18 Hotel and motel fire safety. The Hotel and Motel Fire Safety Act of 1990 (Public Law 101-391) establishes a number of fire...

  14. Impact of reduced ignition propensity cigarette regulation on consumer smoking behavior and quit intentions: evidence from 6 waves (2004–11) of the ITC Four Country Survey

    PubMed Central

    2013-01-01

    Background Although on the decline, smoking-related fires remain a leading cause of fire death in the United States and United Kingdom and account for over 10% of fire-related deaths worldwide. This has prompted lawmakers to enact legislation requiring manufacturers to implement reduced ignition propensity (RIP) safety standards for cigarettes. The current research evaluates how implementation of RIP safety standards in different countries influenced smokers’ perceptions of cigarette self-extinguishment, frequency of extinguishment, and the impact on consumer smoking behaviors, including cigarettes smoked per day and planning to quit. Methods Participants for this research come from Waves 3 through 8 of the International Tobacco Control (ITC) Four Country Survey conducted longitudinally from 2004 through 2011 in the United States, United Kingdom, Australia, and Canada. Results Perceptions of cigarette self-extinguishment and frequency of extinguishment increased concurrently with an increase in the prevalence of RIP safety standards for cigarettes. Presence of RIP safety standards was also associated with a greater intention to quit smoking, but was not associated with the number of cigarettes smoked per day. Intention to quit was higher among those who were more likely to report that their cigarettes self-extinguish sometimes and often, but we found no evidence of an interaction between frequency of extinguishment and RIP safety standards on quit intentions. Conclusions Overall, because these standards largely do not influence consumer smoking behavior, RIP implementation may significantly reduce the number of cigarette-related fires and the associated death and damages. Further research should assess how implementation of RIP safety standards has influenced smoking-related fire incidence, deaths, and other costs associated with smoking-related fires. PMID:24359292

  15. Impact of reduced ignition propensity cigarette regulation on consumer smoking behavior and quit intentions: evidence from 6 waves (2004-11) of the ITC Four Country Survey.

    PubMed

    Adkison, Sarah E; O'Connor, Richard J; Borland, Ron; Yong, Hua-Hie; Cummings, K Michael; Hammond, David; Fong, Geoffrey T

    2013-12-21

    Although on the decline, smoking-related fires remain a leading cause of fire death in the United States and United Kingdom and account for over 10% of fire-related deaths worldwide. This has prompted lawmakers to enact legislation requiring manufacturers to implement reduced ignition propensity (RIP) safety standards for cigarettes. The current research evaluates how implementation of RIP safety standards in different countries influenced smokers' perceptions of cigarette self-extinguishment, frequency of extinguishment, and the impact on consumer smoking behaviors, including cigarettes smoked per day and planning to quit. Participants for this research come from Waves 3 through 8 of the International Tobacco Control (ITC) Four Country Survey conducted longitudinally from 2004 through 2011 in the United States, United Kingdom, Australia, and Canada. Perceptions of cigarette self-extinguishment and frequency of extinguishment increased concurrently with an increase in the prevalence of RIP safety standards for cigarettes. Presence of RIP safety standards was also associated with a greater intention to quit smoking, but was not associated with the number of cigarettes smoked per day. Intention to quit was higher among those who were more likely to report that their cigarettes self-extinguish sometimes and often, but we found no evidence of an interaction between frequency of extinguishment and RIP safety standards on quit intentions. Overall, because these standards largely do not influence consumer smoking behavior, RIP implementation may significantly reduce the number of cigarette-related fires and the associated death and damages. Further research should assess how implementation of RIP safety standards has influenced smoking-related fire incidence, deaths, and other costs associated with smoking-related fires.

  16. Crisis management of fire in the OR.

    PubMed

    Seifert, Patricia C; Peterson, Erik; Graham, Karen

    2015-02-01

    Fire in the OR is a life-threatening emergency that demands prompt, coordinated, and effective interventions. Specific applications of fire protocols and guidelines for perioperative nurses and their interprofessional colleagues may take several approaches. The perioperative nurse’s role is one that can frequently prevent or ameliorate the damaging thermal effects of a fire. For example, to some degree, the nurse can control all three components of the fire triangle: the ignition sources used during surgery (eg, fiberoptic lights, ESU devices), the oxidizers (eg, room air, supplemental oxygen administered during procedures under straight local anesthesia), and the fuel sources (eg, alcohol-based prep solutions). Although all members of the surgical team play an important role, the ability of and the opportunity for the nurse to minimize the risks of fire are important patient safety attributes of the nurse. Team training, rehearsing appropriate actions, and reacting effectively are essential to preparing health care providers to respond in emergent situations and be able to deliver optimal care. In most jurisdictions, any fired--regardless of size--must be reported to the local fire department. Personnel, managers, and administrators should be prepared also for the possibility of participating in postcrisis evaluations by the fire marshal, The Joint Commission, the Occupational Safety and Health Administration, Centers for Medicare & Medicaid Services, and possibly other fire safety-related organizations. Additionally, supplemental information related to investigating a fire is available through the ECRI Institute.28 The ECRI Institute serves as a third-party investigator and can facilitate root-cause analyses, identify whether the crisis ought to be reported and to whom, and assist in restoring clinical operations.

  17. Health and environmental effects of refuse derived fuel (RDF) production and RDF/coal co-firing technologies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Toole, J.J.; Wessels, T.E.; Lynch, J.F.

    1981-10-01

    Six facilities, representing the scope of different co-firing techniques with their associated RDF production systems were reviewed in detail for combustion equipment, firing modes, emission control systems, residue handling/disposal, and effluent wastewater treatment. These facilities encompass all currently operational or soon to be operational co-firing plants and associated RDF production systems. Occupational health and safety risks for these plants were evaluated on the basis of fatal and nonfatal accidents and disease arising from the respective fuel cycles, coal and RDF. Occupational risks include exposure to pathogenic organisms in the workplace. Unusual events that are life threatening in the RDF processingmore » industry (e.g., explosions) are also discussed and remedial and safety measures reviewed. 80 refs., 4 figs., 30 tabs.« less

  18. 76 FR 10246 - Updating Fire Safety Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-24

    ... DEPARTMENT OF VETERANS AFFAIRS 38 CFR Parts 17 and 59 RIN 2900-AN57 Updating Fire Safety Standards... regulations and update the standards for VA approval of such facilities, including standards for fire safety... to ``RIN 2900-AN57--Updating Fire Safety [[Page 10247

  19. Carbon Dioxide Dispersion in the Combustion Integrated Rack Simulated Numerically

    NASA Technical Reports Server (NTRS)

    Wu, Ming-Shin; Ruff, Gary A.

    2004-01-01

    When discharged into an International Space Station (ISS) payload rack, a carbon dioxide (CO2) portable fire extinguisher (PFE) must extinguish a fire by decreasing the oxygen in the rack by 50 percent within 60 sec. The length of time needed for this oxygen reduction throughout the rack and the length of time that the CO2 concentration remains high enough to prevent the fire from reigniting is important when determining the effectiveness of the response and postfire procedures. Furthermore, in the absence of gravity, the local flow velocity can make the difference between a fire that spreads rapidly and one that self-extinguishes after ignition. A numerical simulation of the discharge of CO2 from PFE into the Combustion Integrated Rack (CIR) in microgravity was performed to obtain the local velocity and CO2 concentration. The complicated flow field around the PFE nozzle exits was modeled by sources of equivalent mass and momentum flux at a location downstream of the nozzle. The time for the concentration of CO2 to reach a level that would extinguish a fire anywhere in the rack was determined using the Fire Dynamics Simulator (FDS), a computational fluid dynamics code developed by the National Institute of Standards and Technology specifically to evaluate the development of a fire and smoke transport. The simulation shows that CO2, as well as any smoke and combustion gases produced by a fire, would be discharged into the ISS cabin through the resource utility panel at the bottom of the rack. These simulations will be validated by comparing the results with velocity and CO2 concentration measurements obtained during the fire suppression system verification tests conducted on the CIR in March 2003. Once these numerical simulations are validated, portions of the ISS labs and living areas will be modeled to determine the local flow conditions before, during, and after a fire event. These simulations can yield specific information about how long it takes for smoke and combustion gases produced by a fire to reach a detector location, how large the fire would be when the detector alarms, and the behavior of the fire until it has been extinguished. This new capability could then be used to optimize the location of fire detectors and fire-suppression ports as well as to evaluate the effectiveness of fire suppressants and response strategies. Numerical data collected from these simulations could also be used to develop a virtual reality fire event for crew training and fire safety awareness. This work is funded by NASA's Bioastronautics Initiative, which has the objective of ensuring and enhancing the health, safety, and performance of humans in space. As part of this initiative, the Microgravity Combustion Science Branch at the NASA Glenn Research Center is conducting spacecraft fire safety research to significantly improve fire safety on inhabited spacecraft.

  20. Fire and worker health and safety: an introduction to the special issue.

    PubMed

    Campbell, Richard; Levenstein, Charles

    2015-02-01

    One century ago, the landmark fire at the Triangle Shirtwaist Factory in New York City claimed the lives of 146 garment workers and helped spur the adoption of fire safety measures and laws targeting dangerous working conditions. Since that time, continuing advances have been made to address the threat of fire-in workplace fire safety practices and regulations, in training and safety requirements for firefighters and first responders, and in hazard communication laws that enhance disaster planning and response. Recent high profile events, including the West, Texas fertilizer plant explosion, derailments of fuel cargo trains, and garment factory fires in Bangladesh, have brought renewed attention to fire as a workplace health and safety issue and to the unevenness of safety standards and regulatory enforcement, in the United States as well as internationally. In this article, we provide an overview of fire as a workplace health and safety hazard and an introduction to the essays included in this special issue of New Solutions on fire and work. © 2015 SAGE Publications.

  1. Fire safety: A case study of technology transfer

    NASA Technical Reports Server (NTRS)

    Heins, C. F.

    1975-01-01

    Two basic ways in which NASA-generated technology is being used by the fire safety community are described. First, improved products and systems that embody NASA technical advances are entering the marketplace. Second, NASA test data and technical information related to fire safety are being used by persons concerned with reducing the hazards of fire through improved design information and standards. The development of commercial fire safety products and systems typically requires adaptation and integration of aerospace technologies that may not have been originated for NASA fire safety applications.

  2. Vehicle fires and fire safety in tunnels

    DOT National Transportation Integrated Search

    2002-09-20

    Tunnels present what is arguably the most hazardous environment, from the point of view of fire safety, that members of the public ever experience. The fire safety design of tunnels is carried out by tunnel engineers on the basis of a potential fire ...

  3. Fire! Fire Prevention and Safety: A Teacher's Handbook.

    ERIC Educational Resources Information Center

    New York City Board of Education, Brooklyn, NY. Div. of Educational Planning and Support.

    In this curriculum guide, guidelines for teaching children about fire safety and related topics and activities representing an interdisciplinary approach to fire safety are outlined. Major fire hazards and methods of dealing with them are described. Possible sites for field trips and films relating to fire are listed. The rules of the New York…

  4. Fire Safety Educational Material.

    ERIC Educational Resources Information Center

    Cohn, Bert M.

    The state of the art of home fire safety educational material was reviewed to prepare a bibliography of home fire safety educational materials available from major public and private sources. Sources contacted were: National Fire Protection Association, National Safety Council, U.S. government agencies, private publishers and film distributors,…

  5. Millwright Apprenticeship. Related Training Modules. 1.1-1.8 Safety.

    ERIC Educational Resources Information Center

    Lane Community Coll., Eugene, OR.

    This packet, part of the instructional materials for the Oregon apprenticeship program for millwright training, contains eight modules covering safety. The modules provide information on the following topics: general safety, hand tool safety, power tool safety, fire safety, hygiene, safety and electricity, types of fire and fire prevention, and…

  6. Initial Evaluation of Burn Characteristics of Phenolic Foam Runway Brake Arrestor Material

    DTIC Science & Technology

    1993-12-01

    foam immersed in a jet fuel fire when extinguished using 3-percent Aqueous Film Forming Foam ( AFFF ). Three pool...extinguishment time of phenolic foam immersed in a jet fuel fire, using 3-percent Aqueous Film Forming Foam ( AFFF ) extinguishing agent. The wind was negligible...percent Aqueous Film Forming Foam ( AFFF ) agent. This project is an initial assessment of the fire safety of phenolic foam

  7. Caught in a tightening fire safety net.

    PubMed

    Baillie, Jonathan

    2008-06-01

    How the Regulatory Reform (Fire Safety) Order 2005 has shifted responsibility for hospital fire safety from local fire authorities to so-called "responsible persons", and the implications for senior management/board-level personnel, as well as for hospital fire officers, fire wardens and department managers charged with implementation, was expertly examined by a leading expert in fire law at May's National Association of Healthcare Fire Officers (NAHFO) 2008 conference in Nottingham. Jonathan Baillie reports.

  8. 75 FR 17641 - Updating Fire Safety Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-07

    ... DEPARTMENT OF VETERANS AFFAIRS 38 CFR Parts 17 and 59 RIN 2900-AN57 Updating Fire Safety Standards... for VA approval of such facilities, including standards for fire safety and heating and cooling... submitted in response to ``RIN 2900-AN57--Updating Fire Safety Standards.'' Copies of comments received will...

  9. 29 CFR 1915.502 - Fire safety plan.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 7 2012-07-01 2012-07-01 false Fire safety plan. 1915.502 Section 1915.502 Labor... Employment § 1915.502 Fire safety plan. (a) Employer responsibilities. The employer must develop and implement a written fire safety plan that covers all the actions that employers and employees must take to...

  10. 29 CFR 1915.502 - Fire safety plan.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 7 2014-07-01 2014-07-01 false Fire safety plan. 1915.502 Section 1915.502 Labor... Employment § 1915.502 Fire safety plan. (a) Employer responsibilities. The employer must develop and implement a written fire safety plan that covers all the actions that employers and employees must take to...

  11. 29 CFR 1915.502 - Fire safety plan.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 7 2013-07-01 2013-07-01 false Fire safety plan. 1915.502 Section 1915.502 Labor... Employment § 1915.502 Fire safety plan. (a) Employer responsibilities. The employer must develop and implement a written fire safety plan that covers all the actions that employers and employees must take to...

  12. Community partnership to promote home fire safety in children with special needs.

    PubMed

    Lehna, Carlee; Janes, Erika G; Rengers, Sharon; Graviss, Jackie; Scrivener, Drane; Knabel, Tom; Carver, Elizabeth; Myers, John

    2014-09-01

    Parents of children with special needs are vigilant as their child may have difficulty independently escaping a burning home. The purpose of this study was to evaluate if providing home fire safety information via a digital video disc (DVD) increases families' knowledge, behavior and ability regarding home fire safety. A school based classroom intervention (using a home fire safety DVD) was provided to parents (n=40) of children with and without special needs to improve home fire safety knowledge, behavior and ability. In addition, parents seen at the Kentucky Commission for Children with Special Health Care Needs clinics (n=47) received the same intervention in cohorts of 1-2 children. For both groups, knowledge, and behavior were measured before and after intervention. Repeated measures ANOVA were used to test for differences between groups and over time. Significance was set at p<0.05. No difference in scores between pre- and post-test scores existed between groups (with special needs vs. without special needs, or classroom vs. individualized instruction). However, some differences were noted for some individual survey questions during post-hoc comparisons. Having a smoke alarm in the home (90% vs. 95%, p=0.029) and having a smoke alarm outside of where everyone sleeps (75% vs. 95%, p=0.005) increased over time and was retained. Having a fire escape plan increased at post intervention (58% vs. 79%, p=0.033), but returned to pre levels at follow-up (58%). Perceived knowledge (7.7 vs. 9.3, p<0.001) and ability (8.7 vs. 9.1, p=0.069) increased over time. Parents of children with special needs had a significant increase in knowledge and behavior over those parents of children without special needs. They also perceived having a high fire safety ability. Many of the post-test questions/behaviors (e.g., capable of exiting home during a fire, etc.) were reported at 100%. The intervention was well received, but may not necessarily be needed. Focus for home fire safety may need to look at younger children and smaller families. Parents of special needs children may have had frequent interaction with health care professionals. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.

  13. Can Preschool Children Learn Safety Skills? Evaluation of the Safe at Home Curriculum.

    ERIC Educational Resources Information Center

    Clark, E. Audrey; Simmons, Robert A.

    The American Lung Association of Los Angeles County developed the SAFE-AT-HOME curriculum to teach preschool children home safety concepts through early childhood group experiences. This report evaluates the efficacy of the curriculum by testing 2 experimental and 2 control groups of children from 34 preschool classes on fire, water, foreign…

  14. Teaching About Fire Safety.

    ERIC Educational Resources Information Center

    Brady, Holly; Arnold, Anne Jurmu

    1982-01-01

    This unit on fire safety teaches students how to act in or during a fire and presents fire prevention measures that students can implement at home. Two reproducible masters concerning fire safety and prevention are presented along with class activities, student reading resources, and organizations and companies that offer classroom materials about…

  15. Teach Children Fire Will Burn.

    ERIC Educational Resources Information Center

    Children's Bureau (DHEW), Washington, DC.

    This handbook, addressed to parents and others responsible for the safety of children, presents information on fire hazards, prevention and protection. Emphasizing an early start to fire safety training, it outlines the basic facts of fire safety education, listing the most frequent causes of fire and suggesting the organization of a Family Fire…

  16. Applications of aerospace technology in industry, a technology transfer profile: Fire safety

    NASA Technical Reports Server (NTRS)

    Kottenstette, J. P.; Freeman, J. E.; Heins, C. R.; Hildred, W. M.; Johnson, F. D.; Staskin, E. R.

    1971-01-01

    The fire safety field is considered as being composed of three parts: an industry, a technology base, and a user base. An overview of the field is presented, including a perspective on the magnitude of the national fire safety problem. Selected NASA contributions to the technology of fire safety are considered. Communication mechanisms, particularly conferences and publications, used by NASA to alert the community to new developments in the fire safety field, are reviewed. Several examples of nonaerospace applications of NASA-generated fire safety technology are also presented. Issues associated with attempts to transfer this technology from the space program to other sectors of the American economy are outlined.

  17. Space station internal environmental and safety concerns

    NASA Technical Reports Server (NTRS)

    Cole, Matthew B.

    1987-01-01

    Space station environmental and safety concerns, especially those involving fires, are discussed. Several types of space station modules and the particular hazards associated with each are briefly surveyed. A brief history of fire detection and suppression aboard spacecraft is given. Microgravity fire behavior, spacecraft fire detector systems, space station fire suppression equipment and procedures, and fire safety in hyperbaric chambers are discussed.

  18. Combustion and fires in low gravity

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1994-01-01

    Fire safety always receives priority attention in NASA mission designs and operations, with emphasis on fire prevention and material acceptance standards. Recently, interest in spacecraft fire-safety research and development has increased because improved understanding of the significant differences between low-gravity and normal-gravity combustion suggests that present fire-safety techniques may be inadequate or, at best, non-optimal; and the complex and permanent orbital operations in Space Station Freedom demand a higher level of safety standards and practices. This presentation outlines current practices and problems in fire prevention and detection for spacecraft, specifically the Space Station Freedom's fire protection. Also addressed are current practices and problems in fire extinguishment for spacecraft.

  19. 49 CFR 238.103 - Fire safety.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Fire safety. 238.103 Section 238.103... § 238.103 Fire safety. (a) Materials. (1) Materials used in constructing a passenger car or a cab of a... section at the time it was tested. (c) Fire safety analysis for procuring new passenger cars and...

  20. 42 CFR 403.744 - Condition of participation: Life safety from fire.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 2 2014-10-01 2014-10-01 false Condition of participation: Life safety from fire... safety from fire. (a) General. An RNHCI must meet the following conditions: (1) Except as otherwise... Safety Code of the National Fire Protection Association. The Director of the Office of the Federal...

  1. 49 CFR 238.103 - Fire safety.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Fire safety. 238.103 Section 238.103... § 238.103 Fire safety. (a) Materials. (1) Materials used in constructing a passenger car or a cab of a... section at the time it was tested. (c) Fire safety analysis for procuring new passenger cars and...

  2. 49 CFR 238.103 - Fire safety.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Fire safety. 238.103 Section 238.103... § 238.103 Fire safety. (a) Materials. (1) Materials used in constructing a passenger car or a cab of a... section at the time it was tested. (c) Fire safety analysis for procuring new passenger cars and...

  3. Development of lightweight, fire-retardant, low-smoke, high-strength, thermally stable aircraft floor paneling

    NASA Technical Reports Server (NTRS)

    Anderson, R. A.; Ougland, R. M.; Karch, R. J.

    1978-01-01

    Extensive fire resistance and mechanical property tests were conducted on sandwich configurations composed of resin-fiberglass laminates bonded with adhesive to Nomex honeycomb and foam core. The test results were used to select a combination of materials that would improve the fire safety of the airplane without sacrificing mechanical performance of the aircraft floor panels. A test panel is being service evaluated in a commercial aircraft.

  4. 30 CFR 75.1103-11 - Tests of fire hydrants and fire hose; record of tests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tests of fire hydrants and fire hose; record of tests. 75.1103-11 Section 75.1103-11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1103-11 Tests of fire hydrants and...

  5. 30 CFR 75.1103-11 - Tests of fire hydrants and fire hose; record of tests.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Tests of fire hydrants and fire hose; record of tests. 75.1103-11 Section 75.1103-11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1103-11 Tests of fire hydrants and...

  6. 30 CFR 75.1103-11 - Tests of fire hydrants and fire hose; record of tests.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Tests of fire hydrants and fire hose; record of tests. 75.1103-11 Section 75.1103-11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1103-11 Tests of fire hydrants and...

  7. 30 CFR 75.1103-11 - Tests of fire hydrants and fire hose; record of tests.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Tests of fire hydrants and fire hose; record of tests. 75.1103-11 Section 75.1103-11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1103-11 Tests of fire hydrants and...

  8. 30 CFR 75.1103-11 - Tests of fire hydrants and fire hose; record of tests.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Tests of fire hydrants and fire hose; record of tests. 75.1103-11 Section 75.1103-11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1103-11 Tests of fire hydrants and...

  9. 36 CFR 910.37 - Fire and life safety.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false Fire and life safety. 910.37... DEVELOPMENT AREA Standards Uniformly Applicable to the Development Area § 910.37 Fire and life safety. As a... recommended that all new development be guided by standards of the NFPA Codes for fire and life safety and...

  10. 36 CFR 910.37 - Fire and life safety.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Fire and life safety. 910.37... DEVELOPMENT AREA Standards Uniformly Applicable to the Development Area § 910.37 Fire and life safety. As a... recommended that all new development be guided by standards of the NFPA Codes for fire and life safety and...

  11. Fire in the Shop!

    ERIC Educational Resources Information Center

    Campbell, Clifton P.; Buchanan, Joseph P.

    1977-01-01

    Fire emergency preparedness measures to take to prevent school fires and to protect against injury and minimize damage when fire does occur are presented. Includes fire safety practices, extinguishers for different classes of fires and their use, and the need for fire safety training in schools. (MF)

  12. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...

  13. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...

  14. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...

  15. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...

  16. Aircraft fire safety research

    NASA Technical Reports Server (NTRS)

    Botteri, Benito P.

    1987-01-01

    During the past 15 years, very significant progress has been made toward enhancing aircraft fire safety in both normal and hostile (combat) operational environments. Most of the major aspects of the aircraft fire safety problem are touched upon here. The technology of aircraft fire protection, although not directly applicable in all cases to spacecraft fire scenarios, nevertheless does provide a solid foundation to build upon. This is particularly true of the extensive research and testing pertaining to aircraft interior fire safety and to onboard inert gas generation systems, both of which are still active areas of investigation.

  17. Applicability of Aerospace Materials Ground Flammability Test Data to Spacecraft Environments Theory and Applied Technologies

    NASA Technical Reports Server (NTRS)

    Hirsch, David; Williams, Jim; Beeson, Harold

    2009-01-01

    This slide presentation reviews the use of ground test data in reference to flammability to spacecraft environments. It reviews the current approach to spacecraft fire safety, the challenges to fire safety that the Constellation program poses, the current trends in the evaluation of the Constellation materials flammability, and the correlation of test data from ground flammability tests with the spacecraft environment. Included is a proposal for testing and the design of experiments to test the flammability of materials under similar spacecraft conditions.

  18. 49 CFR 238.103 - Fire safety.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Fire safety. 238.103 Section 238.103..., DEPARTMENT OF TRANSPORTATION PASSENGER EQUIPMENT SAFETY STANDARDS Safety Planning and General Requirements § 238.103 Fire safety. (a) Materials. (1) Materials used in constructing a passenger car or a cab of a...

  19. Impact of a community based fire prevention intervention on fire safety knowledge and behavior in elementary school children

    PubMed Central

    Hwang, V; Duchossois, G P; Garcia‐Espana, J F; Durbin, D R

    2006-01-01

    The objective of this study was to determine the impact of a community based fire prevention intervention directed only to parents on the fire safety knowledge and behavior in elementary school children. This was a prospective, quasi‐randomized controlled study in which third and fourth grade students from two elementary schools in an urban, poor, minority community completed knowledge/behavior surveys at baseline and following completion of the intervention. The intervention group received an in‐home visit from fire department personnel who installed free lithium smoke detectors and provided a fire escape plan. After accounting for a small difference in baseline summary scores of knowledge and behavior between the control and intervention groups, this study found a modest improvement in fire safety behavior among children whose families received a fire prevention intervention reflecting a change in household fire safety practices. However, there was no significant change in fire safety knowledge. PMID:17018679

  20. Research Needs in Fire Safety for the Human Exploration and Utilization of Space

    NASA Technical Reports Server (NTRS)

    Ruff, Gary A.

    2003-01-01

    This viewgraph presentation provides information on developments in spacecraft fire safety research. The presentation includes an overview of the previous Spacecraft Fire Safety Workshop, from 1986, and the influences since then of bioastronautics on combustion science and fire safety. The presentation then gives of overview of the current conference, stating goals and giving a schedule.

  1. Acquisition of Fire Safety Knowledge and Skills With Virtual Reality Simulation.

    PubMed

    Rossler, Kelly L; Sankaranarayanan, Ganesh; Duvall, Adrianne

    2018-05-25

    Prelicensure nursing students seeking to enter perioperative nursing need preparatory fire safety knowledge and skills training to participate as a member of an operating room (OR) team. This pilot study examined the effectiveness of the Virtual Electrosurgery Skill Trainer (VEST) on OR fire safety skills among prelicensure nursing students. An experimental pretest-posttest design was used in this study. Twenty nursing students were randomized to a control or an intervention group. Knowledge and skills acquisition of OR fire safety were assessed. There were no statistically significant findings in knowledge for either group. Fisher exact test demonstrated significant relationships between the skills performance criteria of following emergency procedures for a fire and demonstrating PASS (pull-aim-squeeze-sweep) technique (P = .001). Academic and hospital educators may consider incorporating virtual reality simulation to teach fire safety education or reinforce general fire safety practices to nursing students and novice nurses.

  2. Help Children--and Families--Learn Basic Fire Safety.

    ERIC Educational Resources Information Center

    Texas Child Care, 2001

    2001-01-01

    Presents tips to help early childhood teachers and caregivers teach young children fire safety. Provides checklist for preventing fires in the kitchen, classrooms, and storage areas. Offers suggestions for classroom learning activities and for educating families about fire safety. Includes annotated bibliography of children's books dealing with…

  3. 76 FR 70885 - Updating Fire Safety Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-16

    ... DEPARTMENT OF VETERANS AFFAIRS 38 CFR Part 59 RIN 2900-AN57 Updating Fire Safety Standards AGENCY... Fire Protection Association (NFPA) 101. This rule helps ensure the safety of veterans in the affected... publications are: NFPA 10, Standard for Portable Fire Extinguishers; NFPA 99, Standard for Health Care...

  4. A full-scale fire program to evaluate new furnishings and textile materials developed by the National Aeronautics and Space Administration

    NASA Technical Reports Server (NTRS)

    Hillenbrand, L. J.; Wray, J. A.

    1974-01-01

    A program of experimental fires was carried out to establish the advantages offered by new materials for improved fire safety. Four full-scale bedrooms, differing only in the materials used to furnish them, were built and burned to provide comparative data on the fire hazards produced. Cost and availability differences were not considered. The visual evidence provided by TV and photographic coverage of the four experimental room fires showed clearly that the rooms responded very differently to a common ignition condition. Resistance to the ignition and spread of fire was substantially improved in the rooms furnished completely or partially with the new materials.

  5. Fire safety evaluation of aircraft lavatory and cargo compartments

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Parker, J. A.; Hilado, C. J.; Anderson, R. A.; Tustin, E.; Arnold, D. E.; Gaume, J. G.; Binding, A. T.; Mikeska, J. L.

    1975-01-01

    Large-scale aircraft lavatory and cargo compartment fire tests are described. Tests were conducted to evaluate the effectiveness of these compartments to contain fire and smoke. Two tests were conducted and are detailed. Test 1 involved a production Boeing 747 lavatory of the latest design installed in an enclosure outside the aircraft, to collect gases and expose animals to these gases. Results indicate that the interior of the lavatory was completely burned, evolving smoke and combustion products in the enclosure. Test 2 involved a simulated Douglas DC-10 cargo compartment retro-fitted with standard fiberglass liner. The fire caused excessive damage to the liner and burned through the ceiling in two areas. Test objectives, methods, materials, and results are presented and discussed.

  6. EVALUATION OF SMOKE AND GAS SENSOR RESPONSES FOR FIRES OF COMMON MINE COMBUSTIBLES

    PubMed Central

    Perera, Inoka Eranda; Litton, Charles D.

    2015-01-01

    Experiments were conducted to evaluate the response characteristics of commercially available gas, smoke, and flame sensors to fires of common combustible mine materials. The experiments were conducted in the large-scale Fire gallery located at the National Institute for Occupational Safety and Health (NIOSH) Lake Lynn Laboratory (LLL) in Fairchance, PA, using Ponderosa Pine, Red Oak, Douglas-fir, high and low volatile coals, PVC and SBR conveyor belt, No. 2 diesel fuel, and diesel exhaust. All the experiments (except those using No. 2 diesel fuel and the diesel exhaust tests) were conducted in a similar manner, with combustible materials heated rapidly by electrical strip heaters producing smoldering fires that quickly transitioned into flaming fires. The sensors included a diffusion-type carbon monoxide (CO) sensor, photoelectric- and ionization-type smoke sensors, a video smoke/flame detector, and an optical flame detector. Simultaneous measurements were obtained for average gas concentrations, smoke mass concentrations, and smoke optical densities in order to quantify the levels of combustion products at the alert and alarm times of the sensors. Because the required sensor alarm levels are 10 ppm and 0.044 m−1 optical density for CO and smoke sensors, respectively, the different sensor alarms are compared to the time at which the CO and smoke reached these alarm levels (1). In addition, the potential impact of using smoke sensors that have met the performance standards from accredited testing laboratories is also evaluated using the response of an Underwriters’ Laboratory (UL)-approved combination photoelectric/ionization smoke detector. The results are discussed relative to fire sensor needs that can have a positive impact on mine fire safety. PMID:26229418

  7. EVALUATION OF SMOKE AND GAS SENSOR RESPONSES FOR FIRES OF COMMON MINE COMBUSTIBLES.

    PubMed

    Perera, Inoka Eranda; Litton, Charles D

    Experiments were conducted to evaluate the response characteristics of commercially available gas, smoke, and flame sensors to fires of common combustible mine materials. The experiments were conducted in the large-scale Fire gallery located at the National Institute for Occupational Safety and Health (NIOSH) Lake Lynn Laboratory (LLL) in Fairchance, PA, using Ponderosa Pine, Red Oak, Douglas-fir, high and low volatile coals, PVC and SBR conveyor belt, No. 2 diesel fuel, and diesel exhaust. All the experiments (except those using No. 2 diesel fuel and the diesel exhaust tests) were conducted in a similar manner, with combustible materials heated rapidly by electrical strip heaters producing smoldering fires that quickly transitioned into flaming fires. The sensors included a diffusion-type carbon monoxide (CO) sensor, photoelectric- and ionization-type smoke sensors, a video smoke/flame detector, and an optical flame detector. Simultaneous measurements were obtained for average gas concentrations, smoke mass concentrations, and smoke optical densities in order to quantify the levels of combustion products at the alert and alarm times of the sensors. Because the required sensor alarm levels are 10 ppm and 0.044 m -1 optical density for CO and smoke sensors, respectively, the different sensor alarms are compared to the time at which the CO and smoke reached these alarm levels (1). In addition, the potential impact of using smoke sensors that have met the performance standards from accredited testing laboratories is also evaluated using the response of an Underwriters' Laboratory (UL)-approved combination photoelectric/ionization smoke detector. The results are discussed relative to fire sensor needs that can have a positive impact on mine fire safety.

  8. Safety survey report EBR-II safety survey, ANL-west health protection, industrial safety and fire protection survey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dunbar, K.A.

    1972-01-10

    A safety survey covering the disciplines of Reactor Safety, Nuclear Criticality Safety, Health Protection and Industrial Safety and Fire Protection was conducted at the ANL-West EBR-II FEF Complex during the period January 10-18, 1972. In addition, the entire ANL-West site was surveyed for Health Protection and Industrial Safety and Fire Protection. The survey was conducted by members of the AEC Chicago Operations Office, a member of RDT-HQ and a member of the RDT-ID site office. Eighteen recommendations resulted from the survey, eleven in the area of Industrial Safety and Fire Protection, five in the area of Reactor Safety and twomore » in the area of Nuclear Criticality Safety.« less

  9. 24 CFR 232.620 - Determination of compliance by HHS.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... of Fire Safety Equipment Special Requirements § 232.620 Determination of compliance by HHS. An... the fire safety equipment has been installed, will be in compliance with the HHS requirements for fire... Security Act upon the installation of the fire safety equipment. The architectural exhibits, as approved...

  10. 46 CFR 62.35-15 - Fire safety.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Fire safety. 62.35-15 Section 62.35-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Requirements for Specific Types of Automated Vital Systems § 62.35-15 Fire safety. (a) All required fire pump...

  11. 78 FR 17140 - Upholstered Furniture Fire Safety Technology; Meeting and Request for Comments

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-20

    ... Furniture Fire Safety Technology; Meeting and Request for Comments AGENCY: Consumer Product Safety... Commission (CPSC, Commission, or we) is announcing its intent to hold a meeting on upholstered furniture fire... http://www.cpsc.gov/meetingsignup.html and click on the link titled, ``Upholstered Furniture Fire...

  12. 46 CFR 62.35-15 - Fire safety.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Fire safety. 62.35-15 Section 62.35-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Requirements for Specific Types of Automated Vital Systems § 62.35-15 Fire safety. (a) All required fire pump...

  13. 30 CFR 75.1107-16 - Inspection of fire suppression devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-16 Section 75.1107-16 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire... Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA...

  14. 30 CFR 75.1107-16 - Inspection of fire suppression devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-16 Section 75.1107-16 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire... Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA...

  15. 48 CFR 2052.235-71 - Safety, health, and fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....235-71 Safety, health, and fire protection. As prescribed in 2035.70(a)(2), the contracting officer... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Safety, health, and fire..., Health, and Fire Protection (JAN 1993) The contractor shall take all reasonable precautions in the...

  16. 48 CFR 2052.235-71 - Safety, health, and fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....235-71 Safety, health, and fire protection. As prescribed in 2035.70(a)(2), the contracting officer... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Safety, health, and fire..., Health, and Fire Protection (JAN 1993) The contractor shall take all reasonable precautions in the...

  17. 48 CFR 2052.235-71 - Safety, health, and fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....235-71 Safety, health, and fire protection. As prescribed in 2035.70(a)(2), the contracting officer... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false Safety, health, and fire..., Health, and Fire Protection (JAN 1993) The contractor shall take all reasonable precautions in the...

  18. 48 CFR 2052.235-71 - Safety, health, and fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....235-71 Safety, health, and fire protection. As prescribed in 2035.70(a)(2), the contracting officer... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Safety, health, and fire..., Health, and Fire Protection (JAN 1993) The contractor shall take all reasonable precautions in the...

  19. An organizational process for promoting home fire safety in two community settings.

    PubMed

    Lehna, Carlee; Twyman, Stephanie; Fahey, Erin; Coty, Mary-Beth; Williams, Joe; Scrivener, Drane; Wishnia, Gracie; Myers, John

    2017-02-01

    The purpose of this study was to describe the home fire safety quality improvement model designed to aid organizations in achieving institutional program goals. The home fire safety model was developed from community-based participatory research (CBPR) applying training-the-trainer methods and is illustrated by an institutional case study. The model is applicable to other types of organizations to improve home fire safety in vulnerable populations. Utilizing the education model leaves trained employees with guided experience to build upon, adapt, and modify the home fire safety intervention to more effectively serve their clientele, promote safety, and meet organizational objectives. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  20. [Considering the current state of fire safety in Taiwan's care environment from the perspective of the nation's worst recent hospital fire].

    PubMed

    Tseng, Wei-Wen; Shih, Chung-Liang; Chien, Shen-Wen

    2013-04-01

    Taiwan's worst hospital fire in history on October 23rd, 2012 at Sinying Hospital's Bei-Men Branch resulted in 13 elderly patient deaths and over 70 injuries. The heavy casualties were due in part to the serious condition of patients. Some patients on life-support machines were unable to move or be moved. This disaster highlights the issue of fire safety in small-scale hospitals that have transformed existing hospital space into special care environments for elderly patients. Compared with medical centers and general hospitals, these small-scale health facilities are ill equipped to deal properly with fire safety management and emergency response issues due to inadequate fire protection facilities, fire safety equipment, and human resources. Small-scale facilities that offer health care and medical services to mostly immobile patients face fire risks that differ significantly from general health care facilities. This paper focuses on fire risks in small-scale facilities and suggests a strategy for fire prevention and emergency response procedures, including countermeasures for fire risk assessment, management, and emergency response, in order to improve fire safety at these institutions in Taiwan.

  1. Safety Performance of Exterior Wall Insulation Material Based on Large Security Concept

    NASA Astrophysics Data System (ADS)

    Zuo, Q. L.; Wang, Y. J.; Li, J. S.

    2018-05-01

    In order to evaluate the fire spread characteristics of building insulation materials under corner fire, an experiment is carried out with small-scale fire spread test system. The change rule of the parameters such as the average height of the flame, the average temperature of the flame and the shape of the flame are analyzed. The variations of the fire spread characteristic parameters of the building insulation materials are investigated. The results show that the average temperature of Expanded Polystyrene (EPS) board, with different thickness, decrease - rise - decrease - increase. During the combustion process, the fire of 4cm thick plate spreads faster.

  2. Fire safety concerns in space operations

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1987-01-01

    This paper reviews the state-of-the-art in fire control techniques and identifies important issues for continuing research, technology, and standards. For the future permanent orbiting facility, the space station, fire prevention and control calls for not only more stringent fire safety due to the long-term and complex missions, but also for simplified and flexible safety rules to accommodate the variety of users. Future research must address a better understanding of the microgravity space environment as it influences fire propagation and extinction and the application of the technology of fire detection, extinguishment, and material assessment. Spacecraft fire safety should also consider the adaptation of methods and concepts derived from aircraft and undersea experience.

  3. Study to develop improved fire resistant aircraft passenger seat materials, phase 1

    NASA Technical Reports Server (NTRS)

    Trabold, E. L.

    1977-01-01

    The procurement and testing of a wide range of candidate materials is reported. Improved fire resistant nonmetallic materials were subjected to tests to evaluate their thermal characteristics, such as burn, smoke generation, heat release rate and toxicity. In addition, candidate materials were evaluated for mechanical, physical and aesthetic properties. Other properties considered included safety, comfort, durability and maintainability. The fiscal year 1977 and the projected 1980 cost data were obtained for aircraft seat materials.

  4. 29 CFR 1915.502 - Fire safety plan.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 7 2011-07-01 2011-07-01 false Fire safety plan. 1915.502 Section 1915.502 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard...

  5. 29 CFR 1915.502 - Fire safety plan.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Fire safety plan. 1915.502 Section 1915.502 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard...

  6. Charged Up for Fire Safety. Fifth Grade. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the fifth grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of fifth grade students, its objectives include: (1) exploring heating equipment safety, (2) analyzing the impact of fire on the outdoor environment and methods to reduce that impact, (3) developing…

  7. Directory of workers in the fire field

    NASA Technical Reports Server (NTRS)

    Kuvshinoff, B. W.; Mcleod, S. B.; Katz, R. G.

    1973-01-01

    A directory was compiled to provide a list of workers engaged in fire research, their addresses and affiliations, and their principal fields of activity. The initial criteria for the selection of names for the directory are recent contributions to fire literature, teaching of subjects relevant to fire science, or participation in or support of fire research programs. With some exceptions, fire service personnel and fire protection engineers were excluded because directories already exist for these professionals. Also excluded are investigators engaged principally in studies of propulsion, combustion, and explosion phenomena, because these areas of study are somewhat aside from the main focus of fire research. For purposes of the directory, fire science is taken to be the body of knowledge, art, and skill related to the investigation, analysis, and interpretation of the phenomena of unwanted fires and the evaluation of materials methods, systems, and equipment related to fire safety, prevention, detection, and suppression.

  8. Fire safety applications for spacecraft

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Olson, Sandra L.

    1989-01-01

    Fire safety for spacecraft is reviewed by first describing current practices, many of which are adapted directly from aircraft. Then, current analyses and experimental knowledge in low-gravity combustion, with implications for fire safety are discussed. In orbiting spacecraft, the detection and suppression of flames are strongly affected by the large reduction in buoyant flows under low gravity. Generally, combustion intensity is reduced in low gravity. There are some notable exceptions, however, one example being the strong enhancement of flames by low-velocity ventilation flows in space. Finally, the future requirements in fire safety, particularly the needs of long-duration space stations in fire prevention, detection, extinguishment, and atmospheric control are examined. The goal of spacecraft fire-safety investigations is the establishment of trade-offs that promote maximum safety without hampering the useful human and scientific activities in space.

  9. Fire Safety Training Handbook.

    ERIC Educational Resources Information Center

    Montgomery County Dept. of Fire and Rescue Services, Rockville, MD. Div. of Fire Prevention.

    Designed for a community fire education effort, particularly in which local volunteers present general information on fire safety to their fellow citizens, this workbook contains nine lessons. Included are an overview of the household fire problem; instruction in basic chemistry and physics of fire, flammable liquids, portable fire extinguishers,…

  10. Revised fire safety system cuts emergency response time.

    PubMed

    Keir, D C

    1979-03-01

    As Margaret R. Pardee Memorial Hospital, Hendersonville, NC. expanded, fire safety plans had to be reevaluated. With each new addition, fire safety responsibilities for hospital personnel multiplied and overlapped. Confusion resulted, and a revised, simplified, and coordinated fire safety system was devised. Seventeen false alarms within one year, caused by a faulty sprinkler system, gave hospital personnel ample opportunity to test the system and iron out unexpected problems.

  11. 36 CFR § 910.37 - Fire and life safety.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... for fire and life safety and that all buildings be equipped with an approved sprinkler system. ... 36 Parks, Forests, and Public Property 3 2013-07-01 2012-07-01 true Fire and life safety. § 910... PENNSYLVANIA AVENUE DEVELOPMENT AREA Standards Uniformly Applicable to the Development Area § 910.37 Fire and...

  12. Comparing the performance of residential fire sprinklers with other life-safety technologies.

    PubMed

    Butry, David T

    2012-09-01

    Residential fire sprinklers have long proven themselves as life-safety technologies to the fire service community. Yet, about 1% of all one- and two-family dwelling fires occur in homes protected by sprinklers. It has been argued that measured sprinkler performance has ignored factors confounding the relationship between sprinkler use and performance. In this analysis, sprinkler performance is measured by comparing 'like' structure fires, while conditioning on smoke detection technology and neighborhood housing and socioeconomic conditions, using propensity score matching. Results show that residential fire sprinklers protect occupant and firefighter health and safety, and are comparable to other life-safety technologies. Published by Elsevier Ltd.

  13. Where's the Fire?

    ERIC Educational Resources Information Center

    Needham, Dorothy

    1977-01-01

    National Fire Protection Week is a perfect time for launching a fire safety learning center. The activities described here are intended to help children recognize fire hazards in their homes, play areas and public buildings; learn how to act intelligently in fire emergencies; be able to share their knowledge of fire safety with others and…

  14. Surgical fires: a patient safety perspective.

    PubMed

    2006-02-01

    A surgical fire is a fire that occurs on or in a surgical patient. Such fires are rare--they occur in only an extremely small percentage of surgical cases. Nevertheless, the actual number of incidents that occur each year may surprise many healthcare professionals. ECRI estimates that 50 to 100 or more surgical fires occur each year in the United States alone. And such fires can have devastating consequences, not only for the patient, but also for the surgical staff and for the healthcare facility. Fortunately, through awareness of the hazards-and with emphasis placed on following safe practices-virtually all surgical fires can be prevented. Thus, it's important that surgical fire safety be incorporated into formal patient safety initiatives. In this article, we describe a few surgical fire patient safety initiatives that have been instituted in recent years. In addition, we describe in detail the causes of surgical fires and the preventive measures that are available for healthcare personnel to follow. In addition, we review how staff should respond in the event of a surgical fire.

  15. Designing fire safe interiors.

    PubMed

    Belles, D W

    1992-01-01

    Any product that causes a fire to grow large is deficient in fire safety performance. A large fire in any building represents a serious hazard. Multiple-death fires almost always are linked to fires that grow quickly to a large size. Interior finishes have large, continuous surfaces over which fire can spread. They are regulated to slow initial fire growth, and must be qualified for use on the basis of fire tests. To obtain meaningful results, specimens must be representative of actual installation. Variables--such as the substrate, the adhesive, and product thickness and density--can affect product performance. The tunnel test may not adequately evaluate some products, such as foam plastics or textile wall coverings, thermoplastic materials, or materials of minimal mass. Where questions exist, products should be evaluated on a full-scale basis. Curtains and draperies are examples of products that ignite easily and spread flames readily. The present method for testing curtains and draperies evaluates one fabric at a time. Although a fabric tested alone may perform well, fabrics that meet test standards individually sometimes perform poorly when tested in combination. Contents and furnishings constitute the major fuels in many fires. Contents may involve paper products and other lightweight materials that are easily ignited and capable of fast fire growth. Similarly, a small source may ignite many items of furniture that are capable of sustained fire growth. Upholstered furniture can reach peak burning rates in less than 5 minutes. Furnishings have been associated with many multiple-death fires.(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Science and technology issues in spacecraft fire safety

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Sacksteder, Kurt R.

    1987-01-01

    The space station, a permanently-inhabited orbiting laboratory, places new demands on spacecraft fire safety. Long-duration missions may call for more-constrained fire controls, but the accessibility of the space station to a variety of users may call for less-restrictive measures. This paper discusses fire safety issues through a review of the state of the art and a presentation of key findings from a recent NASA Lewis Research Center Workshop. The subjects covered are the fundamental science of low-gravity combustion and the technology advances in fire detection, extinguishment, materials assessment, and atmosphere selection. Key concerns are for the adoption of a fire-safe atmosphere and the substitution for the effective but toxic extinguishant, halon 1301. The fire safety studies and reviews provide several recommendations for further action. One is the expanded research in combustion, sensors, and materials in the low-gravity environment of space. Another is the development of generalized fire-safety standards for spacecraft through cooperative endeavors with aerospace and outside Government and industry sources.

  17. 29 CFR Appendix D to Subpart L of... - Availability of Publications Incorporated by Reference in Section 1910.156 Fire Brigades

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Criteria for Structural Firefighter's Helmets” (1977) U.S. Fire Administration, National Fire Safety and... Section 1910.156 Fire Brigades D Appendix D to Subpart L of Part 1910 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH...

  18. Measuring behaviours for escaping from house fires: use of latent variable models to summarise multiple behaviours.

    PubMed

    Ploubidis, G B; Edwards, P; Kendrick, D

    2015-12-15

    This paper reports the development and testing of a construct measuring parental fire safety behaviours for planning escape from a house fire. Latent variable modelling of data on parental-reported fire safety behaviours and plans for escaping from a house fire and multivariable logistic regression to quantify the association between groups defined by the latent variable modelling and parental-report of having a plan for escaping from a house fire. Data comes from 1112 participants in a cluster randomised controlled trial set in children's centres in 4 study centres in the UK. A two class model provided the best fit to the data, combining responses to five fire safety planning behaviours. The first group ('more behaviours for escaping from a house fire') comprised 86% of participants who were most likely to have a torch, be aware of how their smoke alarm sounds, to have external door and window keys accessible, and exits clear. The second group ('fewer behaviours for escaping from a house fire') comprised 14% of participants who were less likely to report these five behaviours. After adjusting for potential confounders, participants allocated to the 'more behaviours for escaping from a house fire group were 2.5 times more likely to report having an escape plan (OR 2.48; 95% CI 1.59-3.86) than those in the "fewer behaviours for escaping from a house fire" group. Multiple fire safety behaviour questions can be combined into a single binary summary measure of fire safety behaviours for escaping from a house fire. Our findings will be useful to future studies wishing to use a single measure of fire safety planning behaviour as measures of outcome or exposure. NCT 01452191. Date of registration 13/10/2011.

  19. The influence of fire exposure on austenitic stainless steel for pressure vessel fitness-for-service assessment: Experimental research

    NASA Astrophysics Data System (ADS)

    Li, Bo; Shu, Wenhua; Zuo, Yantian

    2017-04-01

    The austenitic stainless steels are widely applied to pressure vessel manufacturing. The fire accident risk exists in almost all the industrial chemical plants. It is necessary to make safety evaluation on the chemical equipment including pressure vessels after fire. Therefore, the present research was conducted on the influences of fire exposure testing under different thermal conditions on the mechanical performance evolution of S30408 austenitic stainless steel for pressure vessel equipment. The metallurgical analysis described typical appearances in micro-structure observed in the material suffered by fire exposure. Moreover, the quantitative degradation of mechanical properties was investigated. The material thermal degradation mechanism and fitness-for-service assessment process of fire damage were further discussed.

  20. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 3 2010-07-01 2010-07-01 false Institutional fire safety policies and fire statistics... fire statistics. (a) Additional definitions that apply to this section. Cause of fire: The factor or... statistics described in paragraph (c) of this section. (2) A description of each on-campus student housing...

  1. 24 CFR 3280.201 - Scope.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.201 Scope. The purpose of this subpart is to set forth requirements that will assure reasonable fire safety to the occupants by reducing fire hazards and by providing measures for early detection. ...

  2. 24 CFR 3280.201 - Scope.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.201 Scope. The purpose of this subpart is to set forth requirements that will assure reasonable fire safety to the occupants by reducing fire hazards and by providing measures for early detection. ...

  3. 24 CFR 3280.201 - Scope.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.201 Scope. The purpose of this subpart is to set forth requirements that will assure reasonable fire safety to the occupants by reducing fire hazards and by providing measures for early detection. ...

  4. 24 CFR 3280.201 - Scope.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.201 Scope. The purpose of this subpart is to set forth requirements that will assure reasonable fire safety to the occupants by reducing fire hazards and by providing measures for early detection. ...

  5. 24 CFR 3280.201 - Scope.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.201 Scope. The purpose of this subpart is to set forth requirements that will assure reasonable fire safety to the occupants by reducing fire hazards and by providing measures for early detection. ...

  6. 29 CFR 1915.501 - General provisions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard... require employers to protect all employees from fire hazards in shipyard employment, including employees...

  7. 29 CFR 1915.501 - General provisions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard... require employers to protect all employees from fire hazards in shipyard employment, including employees...

  8. 29 CFR 1915.501 - General provisions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard... require employers to protect all employees from fire hazards in shipyard employment, including employees...

  9. The Safety Analysis of Shipborne Ammunition in Fire Environment

    NASA Astrophysics Data System (ADS)

    Ren, Junpeng; Wang, Xudong; Yue, Pengfei

    2017-12-01

    The safety of Ammunition has always been the focus of national military science and technology issues. And fire is one of the major safety threats to the ship’s ammunition storage environment, In this paper, Mk-82 shipborne aviation bomb has been taken as the study object, simulated the whole process of fire by using the FDS (Fire Detection System) software. According to the simulation results of FDS, ANSYS software was used to simulate the temperature field of Mk-82 carrier-based aviation bomb under fire environment, and the safety of aviation bomb in fire environment was analyzed. The result shows that the aviation bombs under the fire environment can occur the combustion or explosion after 70s constant cook-off, and it was a huge threat to the ship security.

  10. Commonalities in Transportation Fire Safety : Regulations, Research and Development, and Data Bases

    DOT National Transportation Integrated Search

    1980-01-01

    This report presents a comprehensive review of current modal fire safety efforts within the U.S. Department of Transportation. Common fire safety problems and modal administration response are identified. Work completed includes a review of modal adm...

  11. House fire injury prevention update. Part II. A review of the effectiveness of preventive interventions

    PubMed Central

    Warda, L.; Tenenbein, M.; Moffatt, M.

    1999-01-01

    Objective—To evaluate and summarize the house fire injury prevention literature. Methods—MEDLINE (1983 to March 1997) was searched by keyword: fire, burn, etiology, cause, prevention, epidemiology, and smoke detector/alarm. ERIC (1966 to March 1997) and PSYCLIT (1974 to June 1997) were searched by keyword: as above, and safety, skills, education, and training. Other sources included references of retrieved publications, review articles, and books; Injury Prevention hand search; government documents; and internet sources. Sources relevant to residential fire injury prevention were selected, evaluated, and summarized. Results—Forty three publications were selected for review, including seven randomized controlled trials, nine quasiexperiments, two natural experiments, 21 prospective cohort studies, two cross sectional surveys, one case report, and one program evaluation. These studies examined the following types of interventions: school (9), preschool (1), and community based educational programs (5); fire response training programs for children (7), blind adolescents (2), and mentally retarded adults (5) and children (1); office based counseling (4); home inspection programs (3); smoke detector giveaway campaigns (5); and smoke detector legislation (1). Conclusions—This review of house fire prevention interventions underscores the importance of program evaluation. There is a need for more rigorous evaluation of educational programs, particularly those targeted at schools. An evidence based, coordinated approach to house fire injury prevention is critical, given current financial constraints and the potential for program overload for communities and schools. PMID:10518271

  12. Incidental Reflector Comparison of Containerized Dry Fire Extinguishing Agents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chapman, Bryan Scott; Wysong, Andrew Russell

    This document addresses the incidental reflector reactivity worth of containerized fire extinguishing agents authorized for use in PF-4 at Los Alamos National Laboratory (LANL). The intent of the document is to analyze dry fire extinguishing agent that remains in a container and is not actively being used in a fire emergency. The incidental reflector reactivity worth is determined by comparison to various thicknesses of close fitting water reflection which is commonly used to bound incidental reflectors in criticality safety evaluations. The conclusion is that even in unlimited quantities, when containerized the authorized dry fire extinguishing agents are bound by 0.4more » inches of close fitting water.« less

  13. Testing and Selection of Fire-Resistant Materials for Spacecraft Use

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Jackson, Brian; Olson, Sandra

    2000-01-01

    Spacecraft fire-safety strategy emphasizes prevention, mostly through the selection of onboard items classified accord- ing to their fire resistance. The principal NASA acceptance tests described in this paper assess the flammability of materials and components under "worst-case" normal-gravity conditions of upward flame spread in controlled-oxygen atmospheres. Tests conducted on the ground, however, cannot duplicate the unique fire characteristics in the nonbuoyant low-gravity environment of orbiting spacecraft. Research shows that flammability an fire-spread rates in low gravity are sensitive to forced convection (ventilation flows) and atmospheric-oxygen concentration. These research results are helping to define new material-screening test methods that will better evaluate material performance in spacecraft.

  14. 24 CFR 3280.209 - Fire testing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Fire testing. 3280.209 Section 3280... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.209 Fire testing. All fire testing conducted in accordance with this subpart shall be performed by nationally recognized testing...

  15. 24 CFR 3280.209 - Fire testing.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Fire testing. 3280.209 Section 3280... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.209 Fire testing. All fire testing conducted in accordance with this subpart shall be performed by nationally recognized testing...

  16. 24 CFR 3280.209 - Fire testing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Fire testing. 3280.209 Section 3280... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.209 Fire testing. All fire testing conducted in accordance with this subpart shall be performed by nationally recognized testing...

  17. 24 CFR 3280.209 - Fire testing.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Fire testing. 3280.209 Section 3280... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.209 Fire testing. All fire testing conducted in accordance with this subpart shall be performed by nationally recognized testing...

  18. Fire safety of ground-based space facilities on the spaceport ;Vostochny;

    NASA Astrophysics Data System (ADS)

    Artamonov, Vladimir S.; Gordienko, Denis M.; Melikhov, Anatoly S.

    2017-06-01

    The facilities of the spaceport ;Vostochny; and the innovative technologies for fire safety to be implemented are considered. The planned approaches and prospects for fire safety ensuring at the facilities of the spaceport ;Vostochny; are presented herein, based on the study of emergency situations having resulted in fire accidents and explosion cases at the facilities supporting space vehicles operation.

  19. 76 FR 3178 - Fire Protection in Shipyard Employment Standard; Extension of the Office of Management and Budget...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-19

    ... (paperwork) requirements. In general, the Standard requires employers to develop a written fire safety plan... of the details of the fire safety plan and that employees have been trained as required by the... to post the fire safety plan or to place it in an area accessible to employees to 12 hours for firms...

  20. Fire Safety: Stop the Heat. Fourth Grade. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the fourth grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of fourth grade students, its objectives include: (1) understanding principles of extinguishing fires, (2) investigating issues of peer pressure related to fire setting, (3) developing…

  1. Medical Oxygen Safety

    MedlinePlus

    ... to the air a patient uses to breathe. Fire needs oxygen to burn. If a fire should start in an oxygen-enriched area, the ... Homes where medical oxygen is used need specific fire safety rules to keep people safe from fire ...

  2. Experimental And Numerical Evaluation Of Gaseous Agents For Suppressing Cup-Burner Flames In Low Gravity

    NASA Technical Reports Server (NTRS)

    Takahashi, Fumiaki; Linteris, Gregory T.; Katta, Viswanath R.

    2003-01-01

    Longer duration missions to the moon, to Mars, and on the International Space Station (ISS) increase the likelihood of accidental fires. NASA's fire safety program for human-crewed space flight is based largely on removing ignition sources and controlling the flammability of the material on-board. There is ongoing research to improve the flammability characterization of materials in low gravity; however, very little research has been conducted on fire suppression in the low-gravity environment. Although the existing suppression systems aboard the Space Shuttle (halon 1301, CF3Br) and the ISS (CO2 or water-based form) may continue to be used, alternative effective agents or techniques are desirable for long-duration missions. The goal of the present investigation is to: (1) understand the physical and chemical processes of fire suppression in various gravity and O2 levels simulating spacecraft, Mars, and moon missions; (2) provide rigorous testing of analytical models, which include detailed combustion-suppression chemistry and radiation sub-models, so that the model can be used to interpret (and predict) the suppression behavior in low gravity; and (3) provide basic research results useful for advances in space fire safety technology, including new fire-extinguishing agents and approaches.

  3. Risks, designs, and research for fire safety in spacecraft

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Sacksteder, Kurt R.; Urban, David

    1991-01-01

    Current fire protection for spacecraft relies mainly on fire prevention through the use of nonflammable materials and strict storage controls of other materials. The Shuttle also has smoke detectors and fire extinguishers, using technology similar to aircraft practices. While experience has shown that the current fire protection is adequate, future improvements in fire safety technology to meet the challenges of long duration space missions, such as the Space Station Freedom, are essential. All spacecraft fire protection systems, however, must deal with the unusual combustion characteristics and operational problems in the low gravity environment. The features of low gravity combustion that affect spacecraft fire safety, and the issues in fire protection for Freedom that must be addressed eventually to provide effective and conservative fire protection systems are discussed.

  4. 48 CFR 245.7311-2 - Safety, security, and fire regulations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Safety, security, and fire regulations. 245.7311-2 Section 245.7311-2 Federal Acquisition Regulations System DEFENSE ACQUISITION... Inventory 245.7311-2 Safety, security, and fire regulations. ...

  5. 30 CFR 57.4560 - Mine entrances.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control... escapeways shall be— (a) Provided with a fire suppression system, other than fire extinguishers and water...

  6. 30 CFR 75.1107-13 - Approval of other fire suppression devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-13 Approval of... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approval of other fire suppression devices. 75...

  7. Fire Safety for Retired Adults: Participant's Coursebook.

    ERIC Educational Resources Information Center

    Walker (Bonnie) and Associates, Inc., Crofton, MD.

    The risk of dying from fire increases substantially among older adults. This document contains a collection of fire safety information for elderly people. Information includes procedures to follow in case of fire and early warning technologies such as smoke alarms. The booklet describes potential sources of fires (smoking, home heating, kitchens,…

  8. 24 CFR 3280.209 - Fire testing.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Fire testing. 3280.209 Section 3280... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.209 Fire testing. Link to an amendment published at 78 FR 73982, Dec. 9, 2013. All fire testing conducted in accordance with...

  9. Fire Safety. Managing School Facilities, Guide 6.

    ERIC Educational Resources Information Center

    Department for Education and Employment, London (England). Architects and Building Branch.

    This booklet discusses how United Kingdom schools can manage fire safety and minimize the risk of fire. The guide examines what legislation school buildings must comply with and covers the major risks. It also describes training and evacuation procedures and provides guidance on fire precautions, alarm systems, fire fighting equipment, and escape…

  10. KSC-2011-6635

    NASA Image and Video Library

    2011-08-31

    CAPE CANAVERAL, Fla. -- Smoke billows from a Huey II helicopter supporting the aviation safety exercise during Emergency Response Safety Training at the Shuttle Landing Facility, Runway 33, at NASA’s Kennedy Space Center in Florida. The simulated helicopter mishap exercise was conducted to evaluate emergency response and mishap investigations of aircraft at Kennedy. Participants included Air Rescue Fire Fighters, Flight Operations, Disaster Preparedness, Security, and Safety. NASA mandates simulated aviation safety training take place every two years. Photo credit: NASA/Kim Shiflett

  11. KSC-2011-6643

    NASA Image and Video Library

    2011-08-31

    CAPE CANAVERAL, Fla. -- The Cape Canaveral Spaceport Mobile Command Center vehicle participates in the aviation safety exercise during Emergency Response Safety Training at the Shuttle Landing Facility, Runway 33, at NASA’s Kennedy Space Center in Florida. The simulated helicopter mishap exercise was conducted to evaluate emergency response and mishap investigations of aircraft at Kennedy. Participants included Air Rescue Fire Fighters, Flight Operations, Disaster Preparedness, Security, and Safety. NASA mandates simulated aviation safety training take place every two years. Photo credit: NASA/Kim Shiflett

  12. Current State of European Railway Fire Safety Research

    DOT National Transportation Integrated Search

    1985-06-01

    This report describes the recent fire safety research and practical fire experience of the major European railways. It includes a summary of the main causes and characteristics of railway vehicle fires, general approaches to the problem, and existing...

  13. 33 CFR 165.152 - Coast Guard Station Fire Island, Long Island, New York-safety zone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... § 165.152 Coast Guard Station Fire Island, Long Island, New York—safety zone. (a) Location. The following waters of Fire Island Inlet are a safety zone: Beginning at a point on shore at 40°37.523′ N, 073... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Coast Guard Station Fire Island...

  14. Children's Knowledge of Fire Safety: A Report for the New Zealand Fire Service.

    ERIC Educational Resources Information Center

    Constable, Cheryl; Renwick, Margery

    The study reported in this document was conducted to measure the impact of the New Zealand Fire Service's new fire safety program on elementary school students. Firefighters in each fire station and voluntary fire brigade in New Zealand were responsible for arranging a visit to every elementary school within their area to present a learning…

  15. Fire Safety's My Job. Eighth Grade. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the eighth grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of eighth grade students, its objectives include: (1) focusing on technical aspects of fire hazards and detection, and (2) exploring fire hazards outside the home. Texas essential elements of…

  16. Responsible for Fire Safety. Seventh Grade. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the seventh grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of seventh grade students, its objectives include: (1) practicing responsible decision-making regarding fire and burn hazards, including peer pressure related to fire risks; and (2) practicing…

  17. Fire safety evaluation of aircraft lavatory and cargo compartments

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Parker, J. A.; Hilado, C. J.; Anderson, R. A.; Tustin, E.; Arnold, D. B.; Gaume, J. G.; Binding, A. T.; Mikeska, J. L.

    1976-01-01

    A program of experimental fires has been carried out to assess fire containment and other fire hazards in lavatory and cargo compartments of wide-body jet aircraft by evaluation of ignition time, burn-through time, fire spread rate, smoke density, evolution of selected combustible and toxic gases, heat flux, and detector response. Two tests were conducted: one involving a standard Boeing 747 lavatory and one involving a simulated DC-10 cargo compartment. A production lavatory module was furnished with conventional materials and was installed in an enclosure. The ignition load was four polyethylene bags containing paper and plastic waste materials representive of a maximum flight cabin waste load. Standard aircraft ventilation conditions were utilized and the lavatory door was closed during the test. Lavatory wall and ceiling panels contained the fire spread during the 30-minute test. Smoke was driven into the enclosure primarily through the ventilation grille in the door and through the gaps between the bifold door and the jamb where the door distorted from the heat earlier in the test. The interior of the lavatory was almost completely destroyed by the fire.

  18. THE EFFECTS OF COMPUTER-BASED FIRE SAFETY TRAINING ON THE KNOWLEDGE, ATTITUDES, AND PRACTICES OF CAREGIVERS

    PubMed Central

    Harrington, Susan S.; Walker, Bonnie L.

    2010-01-01

    Background Older adults in small residential board and care facilities are at a particularly high risk of fire death and injury because of their characteristics and environment. Methods The authors investigated computer-based instruction as a way to teach fire emergency planning to owners, operators, and staff of small residential board and care facilities. Participants (N = 59) were randomly assigned to a treatment or control group. Results Study participants who completed the training significantly improved their scores from pre- to posttest when compared to a control group. Participants indicated on the course evaluation that the computers were easy to use for training (97%) and that they would like to use computers for future training courses (97%). Conclusions This study demonstrates the potential for using interactive computer-based training as a viable alternative to instructor-led training to meet the fire safety training needs of owners, operators, and staff of small board and care facilities for the elderly. PMID:19263929

  19. Heat Transfer Principles in Thermal Calculation of Structures in Fire

    PubMed Central

    Zhang, Chao; Usmani, Asif

    2016-01-01

    Structural fire engineering (SFE) is a relatively new interdisciplinary subject, which requires a comprehensive knowledge of heat transfer, fire dynamics and structural analysis. It is predominantly the community of structural engineers who currently carry out most of the structural fire engineering research and design work. The structural engineering curriculum in universities and colleges do not usually include courses in heat transfer and fire dynamics. In some institutions of higher education, there are graduate courses for fire resistant design which focus on the design approaches in codes. As a result, structural engineers who are responsible for structural fire safety and are competent to do their jobs by following the rules specified in prescriptive codes may find it difficult to move toward performance-based fire safety design which requires a deep understanding of both fire and heat. Fire safety engineers, on the other hand, are usually focused on fire development and smoke control, and may not be familiar with the heat transfer principles used in structural fire analysis, or structural failure analysis. This paper discusses the fundamental heat transfer principles in thermal calculation of structures in fire, which might serve as an educational guide for students, engineers and researchers. Insights on problems which are commonly ignored in performance based fire safety design are also presented. PMID:26783379

  20. First Aid: Burns

    MedlinePlus

    ... for: Parents Kids Teens Kitchen: Household Safety Checklist Fireworks Safety First Aid: Sunburn Firesetting Fire Safety Burns ... Being Safe in the Kitchen Finding Out About Fireworks Safety Playing With Fire? Dealing With Burns Fireworks ...

  1. Fire Safety in Nursing Facilities: Participant's Coursebook.

    ERIC Educational Resources Information Center

    Walker (Bonnie) and Associates, Inc., Crofton, MD.

    Fewer people die in nursing facility fires than in fires occurring in other places where older people live. Fire remains, however, a significant threat in nursing facilities. This book is centered around six "modules" that present a fire safety training program for managers and staff in nursing homes. These modules present the following…

  2. 30 CFR 57.4202 - Fire hydrants.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fire hydrants. 57.4202 Section 57.4202 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control...

  3. 30 CFR 56.4202 - Fire hydrants.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fire hydrants. 56.4202 Section 56.4202 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control...

  4. 30 CFR 57.4230 - Surface self-propelled equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 57.4230 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire... fire or its effects could impede escape from self-propelled equipment, a fire extinguisher shall be on...

  5. 41 CFR 102-80.110 - What must an equivalent level of safety analysis indicate?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., and reliability of all building systems impacting fire growth, occupant knowledge of the fire, and... Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Accident and Fire Prevention Equivalent Level of Safety...

  6. 41 CFR 102-80.110 - What must an equivalent level of safety analysis indicate?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., and reliability of all building systems impacting fire growth, occupant knowledge of the fire, and... Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Accident and Fire Prevention Equivalent Level of Safety...

  7. 41 CFR 102-80.110 - What must an equivalent level of safety analysis indicate?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., and reliability of all building systems impacting fire growth, occupant knowledge of the fire, and... Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Accident and Fire Prevention Equivalent Level of Safety...

  8. 41 CFR 102-80.110 - What must an equivalent level of safety analysis indicate?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., and reliability of all building systems impacting fire growth, occupant knowledge of the fire, and... Management Federal Property Management Regulations System (Continued) FEDERAL MANAGEMENT REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Accident and Fire Prevention Equivalent Level of Safety...

  9. 77 FR 4897 - Safety Zone; M/V Del Monte Live-Fire Gun Exercise, James River, Isle of Wight, VA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-01

    ...-AA00 Safety Zone; M/V Del Monte Live-Fire Gun Exercise, James River, Isle of Wight, VA AGENCY: Coast... provide for the safety of life on navigable waters during the live-fire gun exercises on the M/V Del Monte... associated with the live-fire gun exercise. DATES: This rule is effective in the CFR on February 1, 2012...

  10. 76 FR 31848 - Safety Zone; M/V Del Monte Live-Fire Gun Exercise, James River, Isle of Wight, Virginia

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-02

    ...-AA00 Safety Zone; M/V Del Monte Live-Fire Gun Exercise, James River, Isle of Wight, Virginia AGENCY... provide for the safety of life on navigable waters during the live-fire gun exercises on the M/V Del Monte... associated with the live-fire gun exercise. DATES: This rule will be effective from 11 a.m. June 6, 2011...

  11. What's Your Fire Safety IQ?

    ERIC Educational Resources Information Center

    PTA Today, 1992

    1992-01-01

    The National Fire Protection Association offers a quiz on fire safety designed to help people learn about the major fire dangers and change the way they respond to them. Recommends that families sit down and take the quiz together, focusing on the correct answers provided. (SM)

  12. Fire Won't Wait--Plan Your Escape!

    ERIC Educational Resources Information Center

    PTA Today, 1991

    1991-01-01

    Discusses the importance of home fire escape drills, detailing fire safety plans. Early detection and warning (smoke detectors) coupled with well-rehearsed escape plans help prevent serious injury. Children need to be taught about fire safety beginning at a very early age. (SM)

  13. 77 FR 32136 - Agency Information Collection Activities:

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-31

    ... Fire Safety Authority of Storage of Explosive Materials. (3) Agency form number, if any, and the... safety of emergency response personnel responding to fires at sites where explosives are stored. The information is provided both orally and in writing to the authority having jurisdiction for fire safety in the...

  14. 24 CFR 232.565 - Maximum loan amount.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Fire Safety Equipment Eligible Security Instruments § 232.565 Maximum loan amount. The principal amount of the loan shall not exceed the lower of the Commissioner's estimate of the cost of the fire safety... Secretary of Health and Human Services and the Commissioner to enhance the fire safety of the project, and...

  15. 24 CFR 232.565 - Maximum loan amount.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Fire Safety Equipment Eligible Security Instruments § 232.565 Maximum loan amount. The principal amount of the loan shall not exceed the lower of the Commissioner's estimate of the cost of the fire safety... Secretary of Health and Human Services and the Commissioner to enhance the fire safety of the project, and...

  16. 24 CFR 232.565 - Maximum loan amount.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Fire Safety Equipment Eligible Security Instruments § 232.565 Maximum loan amount. The principal amount of the loan shall not exceed the lower of the Commissioner's estimate of the cost of the fire safety... Secretary of Health and Human Services and the Commissioner to enhance the fire safety of the project, and...

  17. 30 CFR 57.4161 - Use of fire underground.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Use of fire underground. 57.4161 Section 57.4161 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention...

  18. 36 CFR 910.37 - Fire and life safety.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... that all buildings be equipped with an approved sprinkler system. ... 36 Parks, Forests, and Public Property 3 2014-07-01 2014-07-01 false Fire and life safety. 910.37... DEVELOPMENT AREA Standards Uniformly Applicable to the Development Area § 910.37 Fire and life safety. As a...

  19. 36 CFR 910.37 - Fire and life safety.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... that all buildings be equipped with an approved sprinkler system. ... 36 Parks, Forests, and Public Property 3 2012-07-01 2012-07-01 false Fire and life safety. 910.37... DEVELOPMENT AREA Standards Uniformly Applicable to the Development Area § 910.37 Fire and life safety. As a...

  20. 77 FR 2306 - Agency Information Collection Activities: Submission for OMB Review; Comment Request, Federal...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-17

    ... Request, Federal Hotel and Motel Fire Safety Declaration Form AGENCY: Federal Emergency Management Agency... Title: Federal Hotel and Motel Fire Safety Declaration Form. Type of information collection: Extension... Numbers: FEMA Form 516-0-1, Federal Hotel and Motel Fire Safety Declaration Form. Abstract: FEMA collects...

  1. A Lifetime for Fire Safety. Health (High School). Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the high school health component of a series of curriculum guides on fire and burn prevention. It is designed to meet the age-specific needs of ninth and tenth grade students. Objectives include: (1) reviewing comprehensive fire and burn prevention techniques and emergency actions; (2) developing an awareness of fire safety…

  2. Fire safety arrangement of inhabited pressurized compartments of manned spacecraft

    NASA Astrophysics Data System (ADS)

    Bolodian, Ivan; Melikhov, Anatoliy; Tanklevskiy, Leonid

    2017-06-01

    The article deals with innovative technical solutions that provide fire safety in inhabited pressurized compartments of manned spacecraft by means of a fireproof device of inhabited pressurized compartments via application of engineering means of fire prevention and fire spreading prevention by lowering fire load in an inhabited pressurized module up to the point when the maximum possible levels of fire factors in an inhabited pressurized compartment of a manned spacecraft are prevented. Represented technical solutions are used at the present time according to stated recommendations during provision of fire safety of equipment created by a number of Russian organizations for equipage of inhabited pressurized compartments of spacecraft of the Russian segment of International space station.

  3. Applications of Living Fire PRA models to Fire Protection Significance Determination Process in Taiwan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De-Cheng, Chen; Chung-Kung, Lo; Tsu-Jen, Lin

    2004-07-01

    The living fire probabilistic risk assessment (PRA) models for all three operating nuclear power plants (NPPs) in Taiwan had been established in December 2000. In that study, a scenario-based PRA approach was adopted to systematically evaluate the fire and smoke hazards and associated risks. Using these fire PRA models developed, a risk-informed application project had also been completed in December 2002 for the evaluation of cable-tray fire-barrier wrapping exemption. This paper presents a new application of the fire PRA models to fire protection issues using the fire protection significance determination process (FP SDP). The fire protection issues studied may involvemore » the selection of appropriate compensatory measures during the period when an automatic fire detection or suppression system in a safety-related fire zone becomes inoperable. The compensatory measure can either be a 24-hour fire watch or an hourly fire patrol. The living fire PRA models were used to estimate the increase in risk associated with the fire protection issue in terms of changes in core damage frequency (CDF) and large early release frequency (LERF). In compliance with SDP at-power and the acceptance guidelines specified in RG 1.174, the fire protection issues in question can be grouped into four categories; red, yellow, white and green, in accordance with the guidelines developed for FD SDP. A 24-hour fire watch is suggested only required for the yellow condition, while an hourly fire patrol may be adopted for the white condition. More limiting requirement is suggested for the red condition, but no special consideration is needed for the green condition. For the calculation of risk measures, risk impacts from any additional fire scenarios that may have been introduced, as well as more severe initiating events and fire damages that may accompany the fire protection issue should be considered carefully. Examples are presented in this paper to illustrate the evaluation process. (authors)« less

  4. Operating room fire prevention: creating an electrosurgical unit fire safety device.

    PubMed

    Culp, William C; Kimbrough, Bradly A; Luna, Sarah; Maguddayao, Aris J

    2014-08-01

    To reduce the incidence of surgical fires. Operating room fires represent a potentially life-threatening hazard and are triggered by the electrosurgical unit (ESU) pencil. Carbon dioxide is a fire suppressant and is a routinely used medical gas. We hypothesize that a shroud of protective carbon dioxide covering the tip of the ESU pencil displaces oxygen, thereby preventing fire ignition. Using 3-dimensional modeling techniques, a polymer sleeve was created and attached to an ESU pencil. This sleeve was connected to a carbon dioxide source and directed the gas through multiple precisely angled ports, generating a cone of fire-suppressive carbon dioxide surrounding the active pencil tip. This device was evaluated in a flammability test chamber containing 21%, 50%, and 100% oxygen with sustained ESU activation. The sleeve was tested with and without carbon dioxide (control) until a fuel was ignited or 30 seconds elapsed. Time to ignition was measured by high-speed videography. Fires were ignited with each control trial (15/15 trials). The control group median ± SD ignition time in 21% oxygen was 3.0 ± 2.4 seconds, in 50% oxygen was 0.1 ± 1.8 seconds, and in 100% oxygen was 0.03 ± 0.1 seconds. No fire was observed when the fire safety device was used in all concentrations of oxygen (0/15 trials; P < 0.0001). The exact 95% confidence interval for absolute risk reduction of fire ignition was 76% to 100%. A sleeve creating a cone of protective carbon dioxide gas enshrouding the sparks from an ESU pencil effectively prevents fire in a high-flammability model. Clinical application of this device may reduce the incidence of operating room fires.

  5. Review of fire test methods and incident data for portable electric cables in underground coal mines

    NASA Astrophysics Data System (ADS)

    Braun, E.

    1981-06-01

    Electrically powered underground coal mining machinery is connected to a load center or distribution box by electric cables. The connecting cables used on mobile machines are required to meet fire performance requirements defined in the Code of Federal Regulations. This report reviews Mine Safety and Health Administration's (MSHA) current test method and compares it to British practices. Incident data for fires caused by trailing cable failures and splice failures were also reviewed. It was found that the MSHA test method is more severe than the British but that neither evaluated grouped cable fire performance. The incident data indicated that the grouped configuration of cables on a reel accounted for a majority of the fires since 1970.

  6. Fight Fire with These Safety Strategies.

    ERIC Educational Resources Information Center

    Jackson, Lisa M.

    1998-01-01

    Provides expert guidelines on ways to keep schools and children safe from building fires, such as maintenance of exits for easy egress in emergencies, maintaining fire-protection systems, and utilizing evacuation planning and drilling. Highlights fire-safety ideas as part of school-building and renovation projects. (GR)

  7. How to Escape a Home Fire (Take This Safety Quiz).

    ERIC Educational Resources Information Center

    PTA Today, 1994

    1994-01-01

    A checklist/safety quiz from the National Fire Protection Association examines individual knowledge of how to escape if a home fire breaks out. The organization recommends that every household develop a fire escape plan and practice it at least twice a year. (SM)

  8. 29 CFR Appendix A to Subpart P to... - Model Fire Safety Plan (Non-Mandatory)

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Subpart P to Part 1915 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... Fire Protection in Shipyard Employment Pt. 1915, Subpt. P, App. A Appendix A to Subpart P to Part 1915... fire. D. Potential ignition sources for fires and how to control them. E. Types of fire protection...

  9. 29 CFR Appendix A to Subpart P to... - Model Fire Safety Plan (Non-Mandatory)

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Subpart P to Part 1915 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... Fire Protection in Shipyard Employment Pt. 1915, Subpt. P, App. A Appendix A to Subpart P to Part 1915... fire. D. Potential ignition sources for fires and how to control them. E. Types of fire protection...

  10. Carbon Monoxide Safety

    MedlinePlus

    ... portable generators? Source: National Institute of Standards and Technology More information on carbon monoxide safety Heating fire safety NFPA Educational Messages Desk Reference – these messages provide fire and ...

  11. Semiannual Report to the Congress. April 1, 2010 - September 30, 2010

    DTIC Science & Technology

    2010-01-01

    passes.” APRIL 1, 2010 TO SEPTEMBER 30, 2010 59 Services USAAA evaluated practices used to manage BlackBerry devices. personnel...practices used to manage cellular telephones and BlackBerry devices by activities at U.S. Army Training and Doctrine Command, U.S. Army Forces...some tanks. In addition, there were fire and safety hazards identified. For example, the Red Hill fuel tunnel complex lacked adequate fire

  12. Research in fire prevention.

    PubMed

    Pearce, N

    1985-10-01

    This paper describes in broad terms, the fire testing programme we carried out on whole bed assemblies in 1984. It should be clear that the tests were carried out in a thoroughly rigorous scientific manner. As always there is more to be done. The immediate task of finding the so called 'safe' bed assembly is proceeding with the search this year for safer pillows. Softer barrier foams are now being produced and it may be that the NHS could use full depth foam mattresses rather than a barrier foam wrap. On the engineering side I have explained the false alarm problem, and I have reviewed some of the research we are doing to see that new technology is used to give us better systems in future. Life safety sprinkler systems give the possibility of truly active fire protection in patient areas. They will enhance fire safety but at the moment no trade-offs can be offered in other areas of fire protection--either active or passive. My final point is that although I have considered the Department's fire research by looking separately at specific projects, the fire safety of a hospital must always be considered as a total package. To be effective, individual components of fire safety must not be considered in isolation but as part of the overall fire safety system.

  13. 14 CFR 139.321 - Handling and storing of hazardous substances and materials.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...

  14. 14 CFR 139.321 - Handling and storing of hazardous substances and materials.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...

  15. 14 CFR 139.321 - Handling and storing of hazardous substances and materials.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...

  16. 14 CFR 139.321 - Handling and storing of hazardous substances and materials.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...

  17. 14 CFR 139.321 - Handling and storing of hazardous substances and materials.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...

  18. Firefighters United for Safety, Ethics, and Ecology (FUSEE): Torchbearers for a new fire management paradigm

    Treesearch

    Timothy Ingalsbee; Joseph Fox; Patrick Withen

    2007-01-01

    Firefighters United for Safety, Ethics, and Ecology (FUSEE) is a nonprofit organization promoting safe, ethical, ecological wildland fire management. FUSEE believes firefighter and community safety are ultimately interdependent with ethical public service, wildlands protection, and ecological restoration of fire-adapted ecosystems. Our members include current, former,...

  19. 24 CFR 232.510 - Commitment and commitment fee.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... of Fire Safety Equipment Fees and Charges § 232.510 Commitment and commitment fee. (a) Issuance of... setting forth the terms and conditions upon which the fire safety loan will be insured. (b) Type of... installation of the fire safety equipment, as determined by the Secretary of HHS. (c) Term of commitment. (1...

  20. 24 CFR 232.510 - Commitment and commitment fee.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... of Fire Safety Equipment Fees and Charges § 232.510 Commitment and commitment fee. (a) Issuance of... setting forth the terms and conditions upon which the fire safety loan will be insured. (b) Type of... installation of the fire safety equipment, as determined by the Secretary of HHS. (c) Term of commitment. (1...

  1. 24 CFR 232.510 - Commitment and commitment fee.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... of Fire Safety Equipment Fees and Charges § 232.510 Commitment and commitment fee. (a) Issuance of... setting forth the terms and conditions upon which the fire safety loan will be insured. (b) Type of... installation of the fire safety equipment, as determined by the Secretary of HHS. (c) Term of commitment. (1...

  2. Operation and Development Status of the Spacecraft Fire Experiments (Saffire)

    NASA Technical Reports Server (NTRS)

    Ruff, Gary A.; Urban, David L.

    2016-01-01

    Since 2012, a series of Spacecraft Fire Experiments (Saffire) have been under development by the Spacecraft Fire Safety Demonstration (SFS Demo) project, funded by NASA's Advanced Exploration Systems Division. The overall objective of this project is to reduce the uncertainty and risk associated with the design of spacecraft fire safety systems for NASA's exploration missions. The approach to achieving this goal has been to define, develop, and conduct experiments that address gaps in spacecraft fire safety knowledge and capabilities identified by NASA's Fire Safety System Maturation Team. The Spacecraft Fire Experiments (Saffire-I, -II, and -III) are material flammability tests at length scales that are realistic for a spacecraft fire in low-gravity. The specific objectives of these three experiments are to (1) determine how rapidly a large scale fire grows in low-gravity and (2) investigate the low-g flammability limits compared to those obtained in NASA's normal gravity material flammability screening test. The experiments will be conducted in Orbital ATK's Cygnus vehicle after it has unberthed from the International Space Station. The tests will be fully automated with the data downlinked at the conclusion of the test before the Cygnus vehicle reenters the atmosphere. This paper discusses the status of the Saffire-I, II, and III experiments followed by a review of the fire safety technology gaps that are driving the development of objectives for the next series of experiments, Saffire-IV, V, and VI.

  3. Safety Education. A Guide To Help Prevent Accidents Associated with the Home, Student Transportation, Disasters, Pedestrians, Passengers, Fires, Consumerism, Recreation.

    ERIC Educational Resources Information Center

    Texas Education Agency, Austin.

    This teacher's guide presents 10 instructional units for one portion of the Texas-approved course in driver and safety education. The units cover the following topics: what is safety?; accident causation and prevention; home safety; student transportation safety; disasters; pedestrian safety; passenger safety; fire safety; consumer safety; and…

  4. Risk-based Spacecraft Fire Safety Experiments

    NASA Technical Reports Server (NTRS)

    Apostolakis, G.; Catton, I.; Issacci, F.; Paulos, T.; Jones, S.; Paxton, K.; Paul, M.

    1992-01-01

    Viewgraphs on risk-based spacecraft fire safety experiments are presented. Spacecraft fire risk can never be reduced to a zero probability. Probabilistic risk assessment is a tool to reduce risk to an acceptable level.

  5. Advanced spacecraft fire safety: Proposed projects and program plan

    NASA Technical Reports Server (NTRS)

    Youngblood, Wallace W.; Vedha-Nayagam, M.

    1989-01-01

    A detailed review identifies spacecraft fire safety issues and the efforts for their resolution, particularly for the threats posed by the increased on-orbit duration, size, and complexity of the Space Station Freedom. Suggestions provided by a survey of Wyle consultants and outside fire safety experts were combined into 30 research and engineering projects. The projects were then prioritized with respect to urgency to meet Freedom design goals, status of enabling technology, cost, and so on, to yield 14 highest priority projects, described in terms of background, work breakdown structure, and schedule. These highest priority projects can be grouped into the thematic areas of fire detection, fire extinguishment, risk assessment, toxicology and human effects, and ground based testing. Recommendations for overall program management stress the need for NASA Headquarters and field center coordination, with information exchange through spacecraft fire safety oversight committees.

  6. An Educational Program Dealing with Fire Safety. Curriculum and Resource Guide.

    ERIC Educational Resources Information Center

    Rhode Island State Dept. of Education, Providence.

    A series of activities for fire safety education in grades K-12 is presented. The document is organized into three parts: grades K-3; 4-6; and 7-12. Each activity is preceded by general and specific concepts to be stressed. Concepts for grades K-3 stress usefulness and types of fire, fire drills, the fire fighting profession, and the…

  7. Fire Safety: Any Time, Any Place. First Grade. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the first grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of first grade students, its objectives include acquiring basic knowledge of fire and burn hazards, developing a basic understanding of simple injury reduction, and encouraging parent involvement.…

  8. Ten Fire Safety Tips for Schools.

    ERIC Educational Resources Information Center

    Lake, James D.

    1999-01-01

    Provides 10 basic tips, compiled from the National Fire Protection Association's Life Safety Code 101, to ensure that educational facilities are fire safe. Tips include use of frequent and unexpected fire drills, limiting wall space of student artwork and teaching materials, being alert to preventing arson, planning speedy and safe emergency…

  9. 30 CFR 75.1103-1 - Automatic fire sensors.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic fire sensors. 75.1103-1 Section 75.1103-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... fire sensors. A fire sensor system shall be installed on each underground belt conveyor. Sensors so...

  10. 30 CFR 75.1103-1 - Automatic fire sensors.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Automatic fire sensors. 75.1103-1 Section 75.1103-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... fire sensors. A fire sensor system shall be installed on each underground belt conveyor. Sensors so...

  11. 30 CFR 75.1103-1 - Automatic fire sensors.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Automatic fire sensors. 75.1103-1 Section 75.1103-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... fire sensors. A fire sensor system shall be installed on each underground belt conveyor. Sensors so...

  12. 30 CFR 75.1103-1 - Automatic fire sensors.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Automatic fire sensors. 75.1103-1 Section 75.1103-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... fire sensors. A fire sensor system shall be installed on each underground belt conveyor. Sensors so...

  13. 30 CFR 75.1103-1 - Automatic fire sensors.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Automatic fire sensors. 75.1103-1 Section 75.1103-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY... fire sensors. A fire sensor system shall be installed on each underground belt conveyor. Sensors so...

  14. Efficacy of a proactive health and safety risk management system in the fire service.

    PubMed

    Poplin, Gerald S; Griffin, Stephanie; Pollack Porter, Keshia; Mallett, Joshua; Hu, Chengcheng; Day-Nash, Virginia; Burgess, Jefferey L

    2018-04-16

    This study evaluated the efficacy of a fire department proactive risk management program aimed at reducing firefighter injuries and their associated costs. Injury data were collected for the intervention fire department and a contemporary control department. Workers' compensation claim frequency and costs were analyzed for the intervention fire department only. Total, exercise, patient transport, and fireground operations injury rates were calculated for both fire departments. There was a post-intervention average annual reduction in injuries (13%), workers' compensation injury claims (30%) and claims costs (21%). Median monthly injury rates comparing the post-intervention to the pre-intervention period did not show statistically significant changes in either the intervention or control fire department. Reduced workers' compensation claims and costs were observed following the risk management intervention, but changes in injury rates were not statistically significant.

  15. 46 CFR 62.35-15 - Fire safety.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Requirements for Specific Types of Automated Vital Systems § 62.35-15 Fire safety. (a) All required fire pump remote control locations must include the controls necessary to charge the firemain and— (1) A firemain...

  16. 46 CFR 62.35-15 - Fire safety.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Requirements for Specific Types of Automated Vital Systems § 62.35-15 Fire safety. (a) All required fire pump remote control locations must include the controls necessary to charge the firemain and— (1) A firemain...

  17. 46 CFR 62.35-15 - Fire safety.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Requirements for Specific Types of Automated Vital Systems § 62.35-15 Fire safety. (a) All required fire pump remote control locations must include the controls necessary to charge the firemain and— (1) A firemain...

  18. Campus Fire Safety Today.

    ERIC Educational Resources Information Center

    Thompson, Mike

    2001-01-01

    Reviews information on recent college and university dormitory fire fatalities, and highlights five examples of building features reported to be major contributing factors in residence-hall fires. Explains how public awareness and expectations are affecting school dormitory safety. (GR)

  19. Smoke Detection: Critical Element of a University Residential Fire Safety Program.

    ERIC Educational Resources Information Center

    Robinson, Donald A.

    1979-01-01

    A program at the University of Massachusetts/Amherst to assess the fire protection needs of its residential system is described. The study culminated in a multiphase fire safety improvement plan. (JMF)

  20. Evaluation of Risk and Possible Mitigation Schemes for Previously Unidentified Hazards

    NASA Technical Reports Server (NTRS)

    Linzey, William; McCutchan, Micah; Traskos, Michael; Gilbrech, Richard; Cherney, Robert; Slenski, George; Thomas, Walter, III

    2006-01-01

    In April 2004, the NASA Engineering and Safety Center (NESC) was commissioned by NASA's Chief Safety and Mission Assurance (S&MA) Officer to review and render a technical opinion on the probability of a catastrophic failure related to this scenario: The Space Shuttle Program (SSP) recognized a zero-fault-tolerant design related to an inadvertent firing of the primary reaction control system (RCS) jets on the Orbiter during mated operations with the International Space Station (ISS). It was determined that an un-commanded firing of an RCS jet could cause serious damage or loss of both the SSP Orbiter and the ISS. Several scenarios were suggested in which an un-commanded firing of the RCS jet is possible. These scenarios include an arc track event in the 28-volt heater circuits that could result in a wire-to-wire short to the adjacent reaction control jet wire. In this worst-case scenario, enough current and power could be applied to activate the reaction control jet valves and fire a thruster. The following report summarizes the work that was sponsored by the NESC as part of their assessment of the Orbiter inadvertent firing of a RCS thruster while attached to the ISS.

  1. 29 CFR 1915.501 - General provisions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard...

  2. 29 CFR 1915.501 - General provisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... safety plan including hazards, controls, fire safety and health rules, and emergency procedures; (ii... Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard...

  3. 33 CFR 165.152 - Coast Guard Station Fire Island, Long Island, New York-safety zone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Coast Guard Station Fire Island, Long Island, New York-safety zone. 165.152 Section 165.152 Navigation and Navigable Waters COAST GUARD... § 165.152 Coast Guard Station Fire Island, Long Island, New York—safety zone. (a) Location. The...

  4. Fire Safety Trianing in Health Care Institutions.

    ERIC Educational Resources Information Center

    American Hospital Association, Chicago, IL.

    The manual details the procedures to be followed in developing and implementing a fire safety plan. The three main steps are first, to organize; second, to set up a procedure and put it in writing; and third, to train and drill employees and staff. Step 1 involves organizing a safety committee, appointing a fire marshall, and seeking help from…

  5. Fire safety distances for open pool fires

    NASA Astrophysics Data System (ADS)

    Sudheer, S.; Kumar, Lokendra; Manjunath, B. S.; Pasi, Amit; Meenakshi, G.; Prabhu, S. V.

    2013-11-01

    Fire accidents that carry huge loss with them have increased in the previous two decades than at any time in the history. Hence, there is a need for understanding the safety distances from different fires with different fuels. Fire safety distances are computed for different open pool fires. Diesel, gasoline and hexane are used as fuels for circular pool diameters of 0.5 m, 0.7 m and 1.0 m. A large square pool fire of 4 m × 4 m is also conducted with diesel as a fuel. All the prescribed distances in this study are purely based on the thermal analysis. IR camera is used to get the thermal images of pool fires and there by the irradiance at different locations is computed. The computed irradiance is presented with the threshold heat flux limits for human beings.

  6. Spacecraft Fire Safety: A Human Space Flight Program Perspective

    NASA Technical Reports Server (NTRS)

    Pedley, Michael D.

    2003-01-01

    This paper presents viewgraphs on the International Space Station's fire safety program from a human space flight perspective. The topics include: 1) Typical Manned Spacecraft Materials; 2) Typical Flammable Hardware Protection; 3) Materials Flammability; 4) Fire Retardants; 5) Nonflammable Foam Cushion Material; 6) Electrical Wire and Cable; 7) Russian Solid-Fuel Oxygen Generator (SFOG); 8) GOX Ignition Mechanisms; 9) Fire Detection; and 10) Fire Suppression.

  7. Overview of safety research

    NASA Technical Reports Server (NTRS)

    Enders, J. H.

    1978-01-01

    Aircraft safety is reviewed by first establishing a perspective of air transportation accidents as a function of calendar year, geographic area, and phase of flight, and then by describing the threats to safety and NASA research underway in the three representative areas of engine operational problems, meteorological phenomena, and fire. Engine rotor burst protection, aircraft nacelle fire extinguishment, the aircraft-weather interface, severe weather wind shears and turbulence, clear air turbulence, and lightning are among the topics covered. Fire impact management through fire resistant materials technology development is emphasized.

  8. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  9. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  10. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  11. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  12. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  13. 30 CFR 75.1103-5 - Automatic fire warning devices; actions and response.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... hours after the belt is stopped, unless an examination for hot rollers and fire is made as prescribed in... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Automatic fire warning devices; actions and... OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire...

  14. 30 CFR 75.1103-5 - Automatic fire warning devices; actions and response.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... hours after the belt is stopped, unless an examination for hot rollers and fire is made as prescribed in... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Automatic fire warning devices; actions and... OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire...

  15. Study of aircraft crashworthiness for fire protection

    NASA Technical Reports Server (NTRS)

    Cominsky, A.

    1981-01-01

    Impact-survivable postcrash fire accidents were surveyed. The data base developed includes foreign and domestic accidents involving airlines and jet aircraft. The emphasis was placed on domestic accidents, airlines, and jet aircraft due principally to availability of information. Only transport category aircraft in commercial service designed under FAR Part 25 were considered. A matrix was prepared to show the relationships between the accident characteristics and the fire fatalities. Typical postcrash fire scenaries were identified. Safety concepts were developed for three engineering categories: cabin interiors - cabin subsystems; power plant - engines and fuel systems; and structural mechanics - primary and secondary structures. The parameters identified for concept evaluation are cost, effectiveness, and societal concerns. Three concepts were selected for design definition and cost and effectiveness analysis: improved fire-resistant seat materials; anti-misting kerosene; and additional cabin emergency exits.

  16. Accidental fires in clinical laboratories.

    PubMed

    Hoeltge, G A; Miller, A; Klein, B R; Hamlin, W B

    1993-12-01

    The National Fire Protection Association, Quincy, Mass, estimates that 169 fires have occurred annually in health care, medical, and chemical laboratories. On the average, there are 13 civilian injuries and $1.5 million per year in direct property damage. Most fires in which the cause or ignition source can be identified originate in malfunctioning electrical equipment (41.6%) or in the facility's electrical distribution system (14.7%). The prevalence of fire safety deficiencies was measured in the College of American Pathologists Laboratory Accreditation Program. Of the 1732 inspected laboratories, 5.5% lacked records of electrical receptacle polarity and ground checks in the preceding year. Of these inspected laboratories, 4.7% had no or incomplete documentation of electrical safety checks on laboratory instruments. There was no evidence of quarterly fire exit drills in 9% of the laboratories. Deficiencies were also found in precautionary labeling (6.8%), in periodic review of safe work practices (4.2%), in the use of safety cans (3.7%), and in venting of flammable liquid storage areas (2.8%). Fire preparedness would be improved if all clinical laboratories had smoke detectors and automatic fire-extinguishing systems. In-service training courses in fire safety should be targeted to the needs of specific service areas.

  17. Multicentre cluster randomised controlled trial evaluating implementation of a fire prevention Injury Prevention Briefing in children's centres: study protocol.

    PubMed

    Deave, Toity; Towner, Elizabeth; McColl, Elaine; Reading, Richard; Sutton, Alex; Coupland, Carol; Cooper, Nicola; Stewart, Jane; Hayes, Mike; Pitchforth, Emma; Watson, Michael; Kendrick, Denise

    2014-01-22

    The UK has one of the highest fatality rates for deaths from fire-related injuries in children aged 0-14 years; these injuries have the steepest social gradient of all injuries in the UK. Children's centres provide children under five years old and their families with a range of services and information, including home safety, but their effectiveness in promoting injury prevention has yet to be evaluated. We developed a fire prevention intervention for use in children's centres comprising an Injury Prevention Briefing (IPB) which provides evidence on what works and best practice from those running injury prevention programmes, and a facilitation package to support implementation of the IPB. This protocol describes the design and methods of a trial evaluating the effectiveness and cost-effectiveness of the IPB and facilitation package in promoting fire prevention. Pragmatic, multicentre cluster randomised controlled trial, with a nested qualitative study, in four study centres in England. Children's centres in the most disadvantaged areas will be eligible to participate and will be randomised to one of three treatment arms comprising: IPB with facilitation package; IPB with no facilitation package; usual care (control). The primary outcome measure will be the proportion of families who have a fire escape plan at follow-up. Eleven children's centres per arm are required to detect an absolute difference in the percentage of families with a fire escape plan of 20% in either of the two intervention arms compared with the control arm, with 80% power and a 5% significance level (2-sided), an intraclass correlation coefficient of 0.05 and assuming outcomes are assessed on 20 families per children's centre. Secondary outcomes include the assessment of the cost-effectiveness of the intervention, other fire safety behaviours and factors associated with degree of implementation of the IPB. This will be the first trial to develop and evaluate a fire prevention intervention for use in children's centres in the UK. Its findings will be generalisable to children's centres in the most disadvantaged areas of the UK and may also be generalisable to similar interventions to prevent other types of injury. http://NCT01452191 (date of registration: 13/10/2011).

  18. Multicentre cluster randomised controlled trial evaluating implementation of a fire prevention Injury Prevention Briefing in children’s centres: study protocol

    PubMed Central

    2014-01-01

    Background The UK has one of the highest fatality rates for deaths from fire-related injuries in children aged 0–14 years; these injuries have the steepest social gradient of all injuries in the UK. Children’s centres provide children under five years old and their families with a range of services and information, including home safety, but their effectiveness in promoting injury prevention has yet to be evaluated. We developed a fire prevention intervention for use in children’s centres comprising an Injury Prevention Briefing (IPB) which provides evidence on what works and best practice from those running injury prevention programmes, and a facilitation package to support implementation of the IPB. This protocol describes the design and methods of a trial evaluating the effectiveness and cost-effectiveness of the IPB and facilitation package in promoting fire prevention. Methods/Design Pragmatic, multicentre cluster randomised controlled trial, with a nested qualitative study, in four study centres in England. Children’s centres in the most disadvantaged areas will be eligible to participate and will be randomised to one of three treatment arms comprising: IPB with facilitation package; IPB with no facilitation package; usual care (control). The primary outcome measure will be the proportion of families who have a fire escape plan at follow-up. Eleven children’s centres per arm are required to detect an absolute difference in the percentage of families with a fire escape plan of 20% in either of the two intervention arms compared with the control arm, with 80% power and a 5% significance level (2-sided), an intraclass correlation coefficient of 0.05 and assuming outcomes are assessed on 20 families per children’s centre. Secondary outcomes include the assessment of the cost-effectiveness of the intervention, other fire safety behaviours and factors associated with degree of implementation of the IPB. Discussion This will be the first trial to develop and evaluate a fire prevention intervention for use in children’s centres in the UK. Its findings will be generalisable to children’s centres in the most disadvantaged areas of the UK and may also be generalisable to similar interventions to prevent other types of injury. Trial registration http://NCT01452191 (date of registration: 13/10/2011). PMID:24450931

  19. Systematic control of nonmetallic materials for improved fire safety

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The elements of a systematic fire safety program are summarized and consist of fire safety criteria, design considerations, testing of materials, development of nonmetallic materials, nonmetallic materials information systems, design reviews, and change control. The system described in this report was developed for the Apollo spacecraft. The system can, however, be tailored to many industrial, commercial, and military activities.

  20. Defining the Role and Responsibility of the Fire Service Within Homeland Security

    DTIC Science & Technology

    2010-03-01

    Occupational Safety and Health NPS Naval Postgraduate School NRF National Response Framework OSHA Occupational Safety and Health Administration ...Kingdom USAR Urban Search and Rescue USFA United States Fire Administration USMA United States Military Academy xiii ACKNOWLEDGMENTS I want...Association (NFPA), the Occupational Safety and Health Administration (OSHA), the United States Fire Administration (USFA), and the National Institute for

  1. Burns and Fire Safety

    MedlinePlus

    Number of Deaths Death Rate Burns and Fire Safety Fact Sheet (2015) Fatalities • 334 children ages 19 and under died from fires or burns ... burns were ages 4 and under. 1 The death rate for children this age (0.73 per 100, ...

  2. Directory of DOT Fire Research, 1979 edition

    DOT National Transportation Integrated Search

    1980-12-01

    This document presents the results of a survey of the fire safety projects conducted by the modal administrations of the U.S. Department of Transportation. Ongoing and recently completed modal fire safety projects for the period June 1978 to December...

  3. Management of a fire in the operating room.

    PubMed

    Kaye, Alan David; Kolinsky, Daniel; Urman, Richard D

    2014-04-01

    Operating room (OR) fires remain a significant source of liability for anesthesia providers and injury for patients, despite existing practice guidelines and other improvements in operating room safety. Factors contributing to OR fires are well understood and these occurrences are generally preventable. OR personnel must be familiar with the fire triad which consists of a fuel supply, an oxidizing agent, and an ignition source. Existing evidence shows that OR-related fires can result in significant patient complications and malpractice claims. Steps to reduce fires include taking appropriate safety measures before a patient is brought to the OR, taking proper preventive measures during surgery, and effectively managing fire and patient complications when they occur. Decreasing the incidence of fires should be a team effort involving the entire OR personnel, including surgeons, anesthesia providers, nurses, scrub technologists, and administrators. Communication and coordination among members of the OR team is essential to creating a culture of safety.

  4. Large Scale Experiments on Spacecraft Fire Safety

    NASA Technical Reports Server (NTRS)

    Urban, David L.; Ruff, Gary A.; Minster, Olivier; Toth, Balazs; Fernandez-Pello, A. Carlos; T'ien, James S.; Torero, Jose L.; Cowlard, Adam J.; Legros, Guillaume; Eigenbrod, Christian; hide

    2012-01-01

    Full scale fire testing complemented by computer modelling has provided significant know how about the risk, prevention and suppression of fire in terrestrial systems (cars, ships, planes, buildings, mines, and tunnels). In comparison, no such testing has been carried out for manned spacecraft due to the complexity, cost and risk associated with operating a long duration fire safety experiment of a relevant size in microgravity. Therefore, there is currently a gap in knowledge of fire behaviour in spacecraft. The entire body of low-gravity fire research has either been conducted in short duration ground-based microgravity facilities or has been limited to very small fuel samples. Still, the work conducted to date has shown that fire behaviour in low-gravity is very different from that in normal-gravity, with differences observed for flammability limits, ignition delay, flame spread behaviour, flame colour and flame structure. As a result, the prediction of the behaviour of fires in reduced gravity is at present not validated. To address this gap in knowledge, a collaborative international project, Spacecraft Fire Safety, has been established with its cornerstone being the development of an experiment (Fire Safety 1) to be conducted on an ISS resupply vehicle, such as the Automated Transfer Vehicle (ATV) or Orbital Cygnus after it leaves the ISS and before it enters the atmosphere. A computer modelling effort will complement the experimental effort. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew removes the need for strict containment of combustion products. This will facilitate the possibility of examining fire behaviour on a scale that is relevant to spacecraft fire safety and will provide unique data for fire model validation. This unprecedented opportunity will expand the understanding of the fundamentals of fire behaviour in spacecraft. The experiment is being developed by an international topical team that is collaboratively defining the experiment requirements and performing supporting analysis, experimentation and technology development. This paper presents the objectives, status and concept of this project.

  5. Large Scale Experiments on Spacecraft Fire Safety

    NASA Technical Reports Server (NTRS)

    Urban, David; Ruff, Gary A.; Minster, Olivier; Fernandez-Pello, A. Carlos; Tien, James S.; Torero, Jose L.; Legros, Guillaume; Eigenbrod, Christian; Smirnov, Nickolay; Fujita, Osamu; hide

    2012-01-01

    Full scale fire testing complemented by computer modelling has provided significant knowhow about the risk, prevention and suppression of fire in terrestrial systems (cars, ships, planes, buildings, mines, and tunnels). In comparison, no such testing has been carried out for manned spacecraft due to the complexity, cost and risk associated with operating a long duration fire safety experiment of a relevant size in microgravity. Therefore, there is currently a gap in knowledge of fire behaviour in spacecraft. The entire body of low-gravity fire research has either been conducted in short duration ground-based microgravity facilities or has been limited to very small fuel samples. Still, the work conducted to date has shown that fire behaviour in low-gravity is very different from that in normal gravity, with differences observed for flammability limits, ignition delay, flame spread behaviour, flame colour and flame structure. As a result, the prediction of the behaviour of fires in reduced gravity is at present not validated. To address this gap in knowledge, a collaborative international project, Spacecraft Fire Safety, has been established with its cornerstone being the development of an experiment (Fire Safety 1) to be conducted on an ISS resupply vehicle, such as the Automated Transfer Vehicle (ATV) or Orbital Cygnus after it leaves the ISS and before it enters the atmosphere. A computer modelling effort will complement the experimental effort. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew removes the need for strict containment of combustion products. This will facilitate the possibility of examining fire behaviour on a scale that is relevant to spacecraft fire safety and will provide unique data for fire model validation. This unprecedented opportunity will expand the understanding of the fundamentals of fire behaviour in spacecraft. The experiment is being developed by an international topical team that is collaboratively defining the experiment requirements and performing supporting analysis, experimentation and technology development. This paper presents the objectives, status and concept of this project.

  6. Report on the oversight assessment of the operational readiness review of the Replacement Tritium Facility at Savannah River Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, B.T.

    1993-03-01

    This report presents the results of an oversight assessment (OA) conducted by the US Department of Energy's (DOE) Office of Environment, Safety and Health (EH) of operational readiness review (ORR) activities for the Replacement Tritium Facility (RTF) located at Savannah River Site (SRS). The EH OA of this facility took place concurrently with an ORR conducted by the DOE Office of Defense Programs (DP). The DP ORR was conducted from January 19 through February 5, 1993. The EH OA was performed in accordance with the protocol and procedures specified in EH Program for Oversight Assessment of Operational Readiness Evaluations formore » Startups and Restarts,'' dated September 15, 1992. The EH OA Team evaluated the DP ORR to determine whether it was thorough and demonstrated sufficient inquisitiveness to verify that the implementation of programs and procedures adequately ensures the protection of worker safety and health. The EH OA Team performed its evaluation of the DP ORR in the following technical areas: occupational safety, industrial hygiene, and respiratory protection; fire protection; and chemical safety. In the areas of fire protection and chemical safety, the EH OA Team conducted independent vertical-slice reviews to confirm DP ORR results. Within each technical area, the EH OA Team reviewed the DP ORR Plan, including the Criteria Review and Approach Documents (CRADs); the qualifications of individual DP ORR team members; the performance of planned DP ORR activities; and the results of the DP ORR.« less

  7. Report on the oversight assessment of the operational readiness review of the Replacement Tritium Facility at Savannah River Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, B.T.

    1993-03-01

    This report presents the results of an oversight assessment (OA) conducted by the US Department of Energy`s (DOE) Office of Environment, Safety and Health (EH) of operational readiness review (ORR) activities for the Replacement Tritium Facility (RTF) located at Savannah River Site (SRS). The EH OA of this facility took place concurrently with an ORR conducted by the DOE Office of Defense Programs (DP). The DP ORR was conducted from January 19 through February 5, 1993. The EH OA was performed in accordance with the protocol and procedures specified in ``EH Program for Oversight Assessment of Operational Readiness Evaluations formore » Startups and Restarts,`` dated September 15, 1992. The EH OA Team evaluated the DP ORR to determine whether it was thorough and demonstrated sufficient inquisitiveness to verify that the implementation of programs and procedures adequately ensures the protection of worker safety and health. The EH OA Team performed its evaluation of the DP ORR in the following technical areas: occupational safety, industrial hygiene, and respiratory protection; fire protection; and chemical safety. In the areas of fire protection and chemical safety, the EH OA Team conducted independent vertical-slice reviews to confirm DP ORR results. Within each technical area, the EH OA Team reviewed the DP ORR Plan, including the Criteria Review and Approach Documents (CRADs); the qualifications of individual DP ORR team members; the performance of planned DP ORR activities; and the results of the DP ORR.« less

  8. Wire insulation degradation and flammability in low gravity

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1994-01-01

    This view-graph presentation covers the following topics: an introduction to spacecraft fire safety, concerns in fire prevention in low gravity, shuttle wire insulation flammability experiment, drop tower risk-based fire safety experiment, and experimental results, conclusions, and proposed studies.

  9. Health hazard evaluation report HETA 90-168-2248, Independence Police Department Indoor Range, Independence, Missouri

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rinehart, R.D.; Almaguer, D.; Klein, M.K.

    1992-08-01

    On February 14, 1990, the National Institute for Occupational Safety and Health (NIOSH) received a request from a management representative of the Independence, Missouri, Police Department Headquarters for a Health Hazard Evaluation. The Police Department requested NIOSH to evaluate the effectiveness of a newly redesigned air handling system installed inside their indoor firing range. On August 6, 1991, NIOSH investigators met with the firing range supervisor and toured the facility. On August 8, ten personal breathing-zone (PBZ) air samples and 3 area air samples were collected on filters inside the range and the filters were subsequently analyzed for lead bymore » atomic absorption spectroscopy (AAS). Surface lead contamination inside the firing range was measured in two locations and hand (dermal) lead contamination was measured on two instructors and two field officers. These samples were also analyzed for lead by AAS.« less

  10. Fire in the OR--developing a fire safety plan.

    PubMed

    McCarthy, Patricia M; Gaucher, Kenneth A

    2004-03-01

    Approximately 100 operating room fire occur each year in the United States. Although rare, fire in a perioperative setting can be disastrous for both patients and staff members. It is crucial that all perioperative departments have a well thought out and previously rehearsed fire plan in place. Multidisciplinary planning and implementation of regularly scheduled and scripted fire drills are essential to prevent adverse outcomes. Fire drills ensure that all staff members are familiar with the use and location of fire pull stations, fire extinguishers, and fire blankets. Fire drills also prepare staff members to evacuate the OR area if necessary. This article provides the information and framework necessary to develop and implement comprehensive OR fire safety plans that could make the difference between life and death in a fire emergency.

  11. 46 CFR 160.170-3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety... Safety of Life at Sea, 1974, as amended. [USCG-2010-0048, 76 FR 63007, Oct. 11, 2011, as amended by USCG...

  12. 46 CFR 160.133-3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety... Convention for the Safety of Life at Sea, 1974, as amended. [USCG-2010-0048, 76 FR 62983, Oct. 11, 2011, as...

  13. 46 CFR 160.170-3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety... Safety of Life at Sea, 1974, as amended. [USCG-2010-0048, 76 FR 63007, Oct. 11, 2011, as amended by USCG...

  14. Large-Scale Spacecraft Fire Safety Experiments in ISS Resupply Vehicles

    NASA Technical Reports Server (NTRS)

    Ruff, Gary A.; Urban, David

    2013-01-01

    Our understanding of the fire safety risk in manned spacecraft has been limited by the small scale of the testing we have been able to conduct in low-gravity. Fire growth and spread cannot be expected to scale linearly with sample size so we cannot make accurate predictions of the behavior of realistic scale fires in spacecraft based on the limited low-g testing to date. As a result, spacecraft fire safety protocols are necessarily very conservative and costly. Future crewed missions are expected to be longer in duration than previous exploration missions outside of low-earth orbit and accordingly, more complex in terms of operations, logistics, and safety. This will increase the challenge of ensuring a fire-safe environment for the crew throughout the mission. Based on our fundamental uncertainty of the behavior of fires in low-gravity, the need for realistic scale testing at reduced gravity has been demonstrated. To address this concern, a spacecraft fire safety research project is underway to reduce the uncertainty and risk in the design of spacecraft fire safety systems by testing at nearly full scale in low-gravity. This project is supported by the NASA Advanced Exploration Systems Program Office in the Human Exploration and Operations Mission Directorate. The activity of this project is supported by an international topical team of fire experts from other space agencies to maximize the utility of the data and to ensure the widest possible scrutiny of the concept. The large-scale space flight experiment will be conducted on three missions; each in an Orbital Sciences Corporation Cygnus vehicle after it has deberthed from the ISS. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew allows the fire products to be released into the cabin. The tests will be fully automated with the data downlinked at the conclusion of the test before the Cygnus vehicle reenters the atmosphere. The international topical team is collaborating with the NASA team in the definition of the experiment requirements and performing supporting analysis, experimentation and technology development.

  15. Safety in the Chemical Laboratory: Advanced Firemanship: How to Teach Your Audience a Lesson.

    ERIC Educational Resources Information Center

    Pitt, Martin J.

    1984-01-01

    Provides tips to assist in preparing a training program designed to show that: (1) fire is dangerous; (2) ordinary individuals can neither understand fire nor extinguish it; and (3) a fire safety officer can do both. (JN)

  16. Alternatives Assessment: Partnership to Evaluate Flame Retardants in Printed Circuit Boards

    EPA Pesticide Factsheets

    The partnership project on flame retardants in printed circuit boards seeks to improve understanding of the environmental and human health impacts of new and current materials that can be used to meet fire safety standards

  17. Motorcoach and school bus fire safety analysis.

    DOT National Transportation Integrated Search

    2016-11-01

    This report documents a motorcoach and school bus fire safety analysis performed by the John A. Volpe National Transportation Systems Center (Volpe) for the Federal Motor Carrier Safety Administration. This report aims to: 1) identify the causes, fre...

  18. Motorcoach and school bus fire safety analysis : technology brief.

    DOT National Transportation Integrated Search

    2016-11-01

    In 2009, the Federal Motor Carrier Safety Administration (FMCSA) published findings from a study entitled Motorcoach Fire Safety Analysis. The objective of this study was to gather and analyze information regarding the causes, frequency, and se...

  19. Ring the Alarm! A Memo to the Schools on Fire and Human Beings.

    ERIC Educational Resources Information Center

    Educational Facilities Labs., Inc., New York, NY.

    An analysis is presented of the handling of the human elements in fire safety. Emphasis is given to considerations such as how fires kill children, the school's responsibility for fire safety, causes of human failure, and the necessity for organized emergency programs and drills. Also included is a check list of items concerned with protection…

  20. 75 FR 44720 - Safety Zone; Live-Fire Gun Exercise, M/V Del Monte, James River, VA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-29

    ...-AA00 Safety Zone; Live-Fire Gun Exercise, M/V Del Monte, James River, VA AGENCY: Coast Guard, DHS... mariners from the hazards associated with live fire and explosive training events. DATES: This rule is... Hampton Roads was notified that the U.S. Navy will conduct a live fire and explosive training event...

  1. 36 CFR Appendix B to Part 1234 - Alternative Certified Fire-Safety Detection and Suppression System(s)

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the system at the base of the main sprinkler riser. l. Fire hydrants must be located within 250 feet... Suppression System(s) 1. General. This Appendix B contains information on the Fire-safety Detection and Suppression System(s) tested by NARA through independent live fire testing that are certified to meet the...

  2. 36 CFR Appendix B to Part 1234 - Alternative Certified Fire-Safety Detection and Suppression System(s)

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the system at the base of the main sprinkler riser. l. Fire hydrants must be located within 250 feet... Suppression System(s) 1. General. This Appendix B contains information on the Fire-safety Detection and Suppression System(s) tested by NARA through independent live fire testing that are certified to meet the...

  3. 36 CFR Appendix B to Part 1234 - Alternative Certified Fire-Safety Detection and Suppression System(s)

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the system at the base of the main sprinkler riser. l. Fire hydrants must be located within 250 feet... Suppression System(s) 1. General. This Appendix B contains information on the Fire-safety Detection and Suppression System(s) tested by NARA through independent live fire testing that are certified to meet the...

  4. Fire Safety for Consumers. Economics (High School). Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the high school economics component of a series of curriculum guides on fire and burn prevention. It is designed to meet the age-specific needs of eleventh and twelfth grade students. Objectives include: (1) developing an awareness of adult responsibilities to preserve family, property, and economy; (2) preparing for…

  5. 75 FR 17644 - Update to NFPA 101, Life Safety Code, for State Home Facilities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-07

    ... DEPARTMENT OF VETERANS AFFAIRS 38 CFR Part 51 RIN 2900-AN59 Update to NFPA 101, Life Safety Code... certain provisions of the 2009 edition of the National Fire Protection Association's NFPA 101, Life Safety... standards regarding life safety and fire safety. DATES: Written comments must be received by VA on or before...

  6. Fire hazard considerations for composites in vehicle design

    NASA Technical Reports Server (NTRS)

    Gordon, Rex B.

    1994-01-01

    Military ground vehicles fires are a significant cause of system loss, equipment damage, and crew injury in both combat and non-combat situations. During combat, the ability to successfully fight an internal fire, without losing fighting and mobility capabilities, is often the key to crew survival and mission success. In addition to enemy hits in combat, vehicle fires are initiated by electrical system failures, fuel line leaks, munitions mishaps and improper personnel actions. If not controlled, such fires can spread to other areas of the vehicle, causing extensive damage and the potential for personnel injury and death. The inherent fire safety characteristics (i.e. ignitability, compartments of these vehicles play a major roll in determining rather a newly started fire becomes a fizzle or a catastrophe. This paper addresses a systems approach to assuring optimum vehicle fire safety during the design phase of complex vehicle systems utilizing extensive uses of composites, plastic and related materials. It provides practical means for defining the potential fire hazard risks during a conceptual design phase, and criteria for the selection of composite materials based on its fire safety characteristics.

  7. Fighting Fire with Fire.

    ERIC Educational Resources Information Center

    Spoor, Dana L.

    1996-01-01

    School districts are integrating security and life-safety systems into school buildings to protect students and property. This proactive approach includes sprinkler systems, fire alarms, and security systems that monitor door movement. Some school districts that are incorporating the latest life-safety technology are in Missouri, Ohio, California,…

  8. Working toward the elimination of residential fire deaths: the Centers for Disease Control and Prevention's Smoke Alarm Installation and Fire Safety Education (SAIFE) program.

    PubMed

    Ballesteros, Michael F; Jackson, Mark L; Martin, Maurice W

    2005-01-01

    To address residential fires and related injuries, the Centers for Disease Control and Prevention funds state health departments to deliver a Smoke Alarm Installation and Fire Safety Education (SAIFE) program in high-risk homes in 16 states. This program involves recruiting local communities and community partners, hiring a local coordinator, canvassing neighborhood homes, installing long-lasting lithium-powered smoke alarms, and providing general fire safety education and 6-month follow-up to determine alarm functionality. Local fire departments are vital community partners in delivering this program. Since the program's inception, more than 212,000 smoke alarms have been installed in more than 126,000 high-risk homes. Additionally, approximately 610 lives have potentially been saved as a result of a program alarm that provided early warning to a dangerous fire incident.

  9. 30 CFR 56.4101 - Warning signs.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control... open flames shall be posted where a fire or explosion hazard exists. ...

  10. 30 CFR 57.4101 - Warning signs.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control... open flames shall be posted where a fire or explosion hazard exists. ...

  11. 30 CFR 56.4530 - Exits.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control... a sufficient number of exits to permit prompt escape in case of fire. ...

  12. A Full-Scale Fire Program to Evaluate New Furnishings and Textile Materials Developed by the National Aeronautics and Space Administration

    NASA Technical Reports Server (NTRS)

    Hillenbrand, L. J.; Wray, J. A.

    1973-01-01

    The plans for the present series of full-scale experimental fires were initiated at the suggestion of NASA following the presentation of a film and discussion illustrating Battelle-Columbus' recent work in fire research. That film showed bedroom-type fires carried out as a part of a program to determine the influence of the cyclic characteristics of real fires under limited ventilation on the burning and pyrolysis properties of the room furnishings. A new series of fires was suggested by NASA designed to show the performance of new fire resistant and fire retardant materials by providing comparative fire and smoldering environmental conditions. More recently, the goal for the new series of fires was written in a meeting with NASA personnel and others at Battelle on May 3 and 4, 1972. The goal was as follows: To establish the need for special materials of improved fire safety in domiciliary settings of public concern, and to assess, in a professionally acceptable manner, the potential of materials arising from the new space-age technology for this purpose. It was anticipated that some new materials arising from the space-age technology and not yet available through conventional commercial channels might provide significant improvements in fire safety if the best of the commercially available materials showed important shortcomings in this area. It was the intent of this program to assess the benefits that could accrue from the use of these new materials. Fire safety is a matter requiring the evaluation of a number of factors. For example, fire resistance and fire spread, visibility during the fire, toxicity of evolved gases, and the fire-fighting problem that is created must be evaluated before the relative hazard can be assessed. The plan of the program provided for sampling and instrumentation to evaluate these factors, consistent with the goal of technological utilization that has been specified. Arrangements were made with the Columbus Fire Department to use an existing six-story concrete building', designed and used as a fire training tower, as the site for the experimental fires. The visual evidence provided by TV and photographic coverage of the four experimental room fires showed clearly that the rooms responded very differently to a common ignition condition. In particular: (1) The Typical room, furnished from conventional retail sources, ignited easily and burned rapidly so that after 8 minutes the contents of the room were nearly destroyed. (2) The Improved room, furnished with materials selected as being among the best commercially available, showed substantial improvement over the Typical room in that there was slower fire spread. However, the relatively complete destruction of the room contents that resulted, and the large amounts of smoke, made it clear that substantial further improvements were needed. This fire was stopped after 29 minutes. (3) The Space-age room, furnished completely with new materials that were not yet commercially available, did not ignite under the common ignition condition and soon demonstrated the substantial improvement in fire resistance available for those components close to the ignition source. A second and larger ignition arrangement showed that this room can burn, but the difficulty with which this was brought about confirmed the improved fire resistance available with use of these materials. (4) The Mixed room ensemble, furnished with 'materials identical to the Typical room except for the substitution of the bed from the Space-age room, illustrated the improvement in control of fire spread available by careful placement of fire materials in the important paths of fire development of an otherwise ordinary room. The most significant hazards at early times in each fire were due to the rapid rise in heat flux and the abrupt obscuration of vision by smoke. The most consistent toxicity hazard was due to CO and its importance would depend on the ability of the occupant to survive the initial heat and smoke menace which characterized each fire room. Other gases and vapors were shown to reach hazardous levels in certain fire rooms and, again, their significance to an occupant, would relate to the times in which such hazards occurred, and probably to the synergistic nature of the hazard arising from mixtures of such gases. Fire retardant items in the room are caused to pyrolyze by the heat of burning from other items in the room and so contribute to combustible and toxic vapor accumulations, even though they may not have entered into the burning process. This effect of a mixture of combustible materials to produce burning and pyrolysis not characteristic of any one item individually we have chosen to call the "ensemble effect". Further full-scale fire trials may be expected to show the significant changes that control the burning and pyrolytic processes and in that event a programmed fire chamber should be developed to yield realistic laboratory results.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laurinat, J.; Kesterson, M.; Hensel, S.

    The documented safety analysis for the Savannah River Site evaluates the consequences of a postulated 1000 °C fire in a glovebox. The radiological dose consequences for a pressurized release of plutonium oxide powder during such a fire depend on the maximum pressure that is attained inside the oxide storage vial. To enable evaluation of the dose consequences, pressure transients and venting flow rates have been calculated for exposure of the storage vial to the fire. A standard B vial with a capacity of approximately 8 cc was selected for analysis. The analysis compares the pressurization rate from heating and evaporationmore » of moisture adsorbed onto the plutonium oxide contents of the vial with the pressure loss due to venting of gas through the threaded connection between the vial cap and body. Tabulated results from the analysis include maximum pressures, maximum venting velocities, and cumulative vial volumes vented during the first 10 minutes of the fire transient. Results are obtained for various amounts of oxide in the vial, various amounts of adsorbed moisture, different vial orientations, and different surface fire exposures.« less

  14. 24 CFR 232.620 - Determination of compliance by HHS.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... AUTHORITIES MORTGAGE INSURANCE FOR NURSING HOMES, INTERMEDIATE CARE FACILITIES, BOARD AND CARE HOMES, AND... of Fire Safety Equipment Special Requirements § 232.620 Determination of compliance by HHS. An... the fire safety equipment has been installed, will be in compliance with the HHS requirements for fire...

  15. Motorcoach fire safety analysis : the causes, frequency, and severity of motorcoach fires in the United States

    DOT National Transportation Integrated Search

    2012-06-28

    The Federal Motor Carrier Safety Administrations (FMCSA) mission is to reduce crashes, injuries, and fatalities on our nations roads involving motor vehicles, and to further its work the agency set out to identify ways to reduce motorcoach fire...

  16. Can Fire and Rescue Services and the National Health Service work together to improve the safety and wellbeing of vulnerable older people? Design of a proof of concept study.

    PubMed

    Lowton, Karen; Laybourne, Anne H; Whiting, David G; Martin, Finbarr C

    2010-12-03

    Older adults are at increased risk both of falling and of experiencing accidental domestic fire. In addition to advanced age, these adverse events share the risk factors of balance or mobility problems, cognitive impairment and socioeconomic deprivation. For both events, the consequences include significant injury and death, and considerable socioeconomic costs for the individual and informal carers, as well as for emergency services, health and social care agencies.Secondary prevention services for older people who have fallen or who are identifiable as being at high risk of falling include NHS Falls clinics, where a multidisciplinary team offers an individualised multifactorial targeted intervention including strength and balance exercise programmes, medication changes and home hazard modification. A similar preventative approach is employed by most Fire and Rescue Services who conduct Home Fire Safety Visits to assess and, if necessary, remedy domestic fire risk, fit free smoke alarms with instruction for use and maintenance, and plan an escape route. We propose that the similarity of population at risk, location, specific risk factors and the commonality of preventative approaches employed could offer net gains in terms of feasibility, effectiveness and acceptability if activities within these two preventative approaches were to be combined. This prospective proof of concept study, currently being conducted in two London boroughs, (Southwark and Lambeth) aims to reduce the incidence of both fires and falls in community-dwelling older adults. It comprises two concurrent 12-month interventions: the integration of 1) fall risk assessments into the Brigade's Home Fire Safety Visit and 2) fire risk assessments into Falls services by inviting older clinic attendees to book a Visit. Our primary objective is to examine the feasibility and effectiveness of these interventions. Furthermore, we are evaluating their acceptability and value to key stakeholders and services users. If our approach proves feasible and the risk assessment is both effective and acceptable, we envisage advocating a partnership model of working more broadly to fire and rescue services and health services in Britain, such that effective integration of preventative services for older people becomes routine for an ageing population.

  17. Children's Knowledge of Fire Safety. Stage 2. The Final Report for the New Zealand Fire Service.

    ERIC Educational Resources Information Center

    Dunn, Karyn; Renwick, Margery

    In 1991 the New Zealand Fire Service planned a primary school fire-safety education program for children from new entrants to form 2. The program introduces a new module to the children each year of their primary education. This study was undertaken in an attempt to measure the effectiveness of the program. A sample of 1,089 children completed…

  18. Engineering and Development Program Plan, Aircraft Cabin Fire Safety.

    DTIC Science & Technology

    1980-06-01

    relative to a postcrash fuel fire, or whether advanced materials provide a significant safety benefit in comparison to inservice materials. if either...have always been controlled by early detection and prompt extinguishment action by effectively trained crew members. In addition, the fire resistant...occupants. g. Develop a computer fire test data bank with broad user availability for inservice and candidate cabin interior materials. h. Identify

  19. Ignorance and Hazards in Academe: The Dilemma of Fire Safety in American Higher Education.

    ERIC Educational Resources Information Center

    Crnkovich, John J.; Dye, Charles M.

    An examination was made of five major campus fires between 1971 and 1983 in an attempt to better understand the fire hazards associated with the operation of a modern U.S. college or university campus. Overall research revealed a general lack of interest in campus fire safety by colleges and universities in the United States and Canada. Analysis…

  20. Final Report: Fire Prevention, Detection, and Suppression Project, Exploration Technology Development Program

    NASA Technical Reports Server (NTRS)

    Ruff, Gary A.

    2011-01-01

    The Fire Prevention, Detection, and Suppression (FPDS) project is a technology development effort within the Exploration Technology Development Program of the Exploration System Missions Directorate (ESMD) that addresses all aspects of fire safety aboard manned exploration systems. The overarching goal for work in the FPDS area is to develop technologies that will ensure crew health and safety on exploration missions by reducing the likelihood of a fire, or, if one does occur, minimizing the risk to the crew, mission, or system. This is accomplished by addressing the areas of (1) fire prevention and material flammability, (2) fire signatures and detection, and (3) fire suppression and response. This report describes the outcomes of this project from the formation of the Exploration Technology Development Program (ETDP) in October 2005 to September 31, 2010 when the Exploration Technology Development Program was replaced by the Enabling Technology Development and Demonstration Program. NASA s fire safety work will continue under this new program and will build upon the accomplishments described herein.

  1. Microfabricated Chemical Sensors for Aerospace Fire Detection Applications

    NASA Technical Reports Server (NTRS)

    Hunter, Gary W.; Neudeck, Philip G.; Fralick, Gustave; Thomas, Valarie; Makel, D.; Liu, C. C.; Ward, B.; Wu, Q. H.

    2001-01-01

    The detection of fires on-board commercial aircraft is extremely important for safety reasons. Although dependable fire detection equipment presently exists within the cabin, detection of fire within the cargo hold has been less reliable and susceptible to false alarms. A second, independent method of fire detection to complement the conventional smoke detection techniques, such as the measurement of chemical species indicative of a fire, will help reduce false alarms and improve aircraft safety. Although many chemical species are indicative of a fire, two species of particular interest are CO and CO2. This paper discusses microfabricated chemical sensor development tailored to meet the needs of fire safety applications. This development is based on progress in three types of technology: 1) Micromachining and microfabrication (Microsystem) technology to fabricate miniaturized sensors. 2) The use of nanocrystalline materials to develop sensors with improved stability combined with higher sensitivity. 3) The development of high temperature semiconductors, especially silicon carbide. The individual sensor being developed and their level of maturity will be presented.

  2. Evaluating implementation of a fire-prevention injury prevention briefing in children's centres: Cluster randomised controlled trial

    PubMed Central

    Deave, Toity; Hawkins, Adrian; Kumar, Arun; Hayes, Mike; Cooper, Nicola; Watson, Michael; Ablewhite, Joanne; Coupland, Carol; Sutton, Alex; Majsak-Newman, Gosia; McDaid, Lisa; Goodenough, Trudy; Beckett, Kate; McColl, Elaine; Reading, Richard; Kendrick, Denise

    2017-01-01

    Background Many developed countries have high mortality rates for fire-related deaths in children aged 0–14 years with steep social gradients. Evidence-based interventions to promote fire safety practices exist, but the impact of implementing a range of these interventions in children’s services has not been assessed. We developed an Injury Prevention Briefing (IPB), which brought together evidence about effective fire safety interventions and good practice in delivering interventions; plus training and facilitation to support its use and evaluated its implementation. Methods We conducted a cluster randomised controlled trial, with integrated qualitative and cost-effectiveness nested studies, across four study sites in England involving children’s centres in disadvantaged areas; participants were staff and families attending those centres. Centres were stratified by study site and randomised within strata to one of three arms: IPB plus facilitation (IPB+), IPB only, usual care. IPB+ centres received initial training and facilitation at months 1, 3, and 8. Baseline data from children’s centres were collected between August 2011 and January 2012 and follow-up data were collected between June 2012 and June 2013. Parent baseline data were collected between January 2012 and May 2012 and follow-up data between May 2013 and September 2013. Data comprised baseline and 12 month parent- and staff-completed questionnaires, facilitation contact data, activity logs and staff interviews. The primary outcome was whether families had a plan for escaping from a house fire. Treatment arms were compared using multilevel models to account for clustering by children’s centre. Results 1112 parents at 36 children’s centres participated. There was no significant effect of the intervention on families’ possession of plans for escaping from a house fire (adjusted odds ratio (AOR) IPB only vs. usual care: 0.93, 95%CI 0.58, 1.49; AOR IPB+ vs. usual care 1.41, 95%CI 0.91, 2.20). However, significantly more families in the intervention arms reported more behaviours for escaping from house fires (AOR IPB only vs. usual care: 2.56, 95%CI 01.38, 4.76; AOR IPB+ vs. usual care 1.78, 95%CI 1.01, 3.15). Conclusion Our study demonstrated that children’s centres can deliver an injury prevention intervention to families in disadvantaged communities and achieve changes in home safety behaviours. PMID:28339460

  3. Evaluating implementation of a fire-prevention injury prevention briefing in children's centres: Cluster randomised controlled trial.

    PubMed

    Deave, Toity; Hawkins, Adrian; Kumar, Arun; Hayes, Mike; Cooper, Nicola; Watson, Michael; Ablewhite, Joanne; Coupland, Carol; Sutton, Alex; Majsak-Newman, Gosia; McDaid, Lisa; Goodenough, Trudy; Beckett, Kate; McColl, Elaine; Reading, Richard; Kendrick, Denise

    2017-01-01

    Many developed countries have high mortality rates for fire-related deaths in children aged 0-14 years with steep social gradients. Evidence-based interventions to promote fire safety practices exist, but the impact of implementing a range of these interventions in children's services has not been assessed. We developed an Injury Prevention Briefing (IPB), which brought together evidence about effective fire safety interventions and good practice in delivering interventions; plus training and facilitation to support its use and evaluated its implementation. We conducted a cluster randomised controlled trial, with integrated qualitative and cost-effectiveness nested studies, across four study sites in England involving children's centres in disadvantaged areas; participants were staff and families attending those centres. Centres were stratified by study site and randomised within strata to one of three arms: IPB plus facilitation (IPB+), IPB only, usual care. IPB+ centres received initial training and facilitation at months 1, 3, and 8. Baseline data from children's centres were collected between August 2011 and January 2012 and follow-up data were collected between June 2012 and June 2013. Parent baseline data were collected between January 2012 and May 2012 and follow-up data between May 2013 and September 2013. Data comprised baseline and 12 month parent- and staff-completed questionnaires, facilitation contact data, activity logs and staff interviews. The primary outcome was whether families had a plan for escaping from a house fire. Treatment arms were compared using multilevel models to account for clustering by children's centre. 1112 parents at 36 children's centres participated. There was no significant effect of the intervention on families' possession of plans for escaping from a house fire (adjusted odds ratio (AOR) IPB only vs. usual care: 0.93, 95%CI 0.58, 1.49; AOR IPB+ vs. usual care 1.41, 95%CI 0.91, 2.20). However, significantly more families in the intervention arms reported more behaviours for escaping from house fires (AOR IPB only vs. usual care: 2.56, 95%CI 01.38, 4.76; AOR IPB+ vs. usual care 1.78, 95%CI 1.01, 3.15). Our study demonstrated that children's centres can deliver an injury prevention intervention to families in disadvantaged communities and achieve changes in home safety behaviours.

  4. 30 CFR 57.4600 - Extinguishing equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....4600 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention... electrically conductive extinguishing agent could create an electrical hazard, a multipurpose dry-chemical fire...

  5. 30 CFR 56.4500 - Heat sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control... shall be separated from combustible materials if a fire hazard could be created. ...

  6. 30 CFR 56.4600 - Extinguishing equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....4600 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and... conductive extinguishing agent could create an electrical hazard, a multipurpose dry-chemical fire...

  7. 30 CFR 57.4500 - Heat sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control... shall be separated from combustible materials if a fire hazard could be created. ...

  8. 30 CFR 57.4532 - Blacksmith shops.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and... combustion; and (c) Inspected for smoldering fires at the end of each shift. ...

  9. 29 CFR 1926.24 - Fire protection and prevention.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION General Safety and Health... and maintenance of an effective fire protection and prevention program at the job site throughout all...

  10. Design of monocular head-mounted displays for increased indoor firefighting safety and efficiency

    NASA Astrophysics Data System (ADS)

    Wilson, Joel; Steingart, Dan; Romero, Russell; Reynolds, Jessica; Mellers, Eric; Redfern, Andrew; Lim, Lloyd; Watts, William; Patton, Colin; Baker, Jessica; Wright, Paul

    2005-05-01

    Four monocular Head-Mounted Display (HMD) prototypes from the Fire Information and Rescue Equipment (FIRE) project at UC Berkeley are presented. The FIRE project aims to give firefighters a system of information technology tools for safer and more efficient firefighting in large buildings. The paper begins by describing the FIRE project and its use of a custom wireless sensor network (WSN) called SmokeNet for personnel tracking. The project aims to address urban/industrial firefighting procedures in need of improvement. Two "user-needs" studies with the Chicago and Berkeley Fire Departments are briefly presented. The FIRE project"s initial HMD prototype designs are then discussed with regard to feedback from the user-needs studies. These prototypes are evaluated in their potential costs and benefits to firefighters and found to need improvement. Next, some currently available commercial HMDs are reviewed and compared in their cost, performance, and potential for use by firefighters. Feedback from the Berkeley Fire Department user-needs study, in which the initial prototypes were demonstrated, is compiled into a concept selection matrix for the next prototypes. This matrix is used to evaluate a variety of HMDs, including some of the commercial units presented, and to select the best design options. Finally, the current prototypes of the two best design options are presented and discussed.

  11. Bridging the divide between fire safety research and fighting fire safely: How do we convey research innovation to contribute more effectively to wildland firefighter safety?

    Treesearch

    Theodore Ted Adams; Bret W. Butler; Sara Brown; Vita Wright; Anne Black

    2017-01-01

    Creating a safe workplace for wildland firefighters has long been at the centre of discussion for researchers and practitioners. The goal of wildland fire safety research has been to protect operational firefighters, yet its contributions often fall short of potential because much is getting lost in the translation of peer-reviewed results to potential and intended...

  12. Using GIS to evaluate a fire safety program in North Carolina.

    PubMed

    Dudley, Thomas; Creppage, Kathleen; Shanahan, Meghan; Proescholdbell, Scott

    2013-10-01

    Evaluating program impact is a critical aspect of public health. Utilizing Geographic Information Systems (GIS) is a novel way to evaluate programs which try to reduce residential fire injuries and deaths. The purpose of this study is to demonstrate the application of GIS within the evaluation of a smoke alarm installation program in North Carolina. This approach incorporates national fire incident data which, when linked with program data, provides a clear depiction of the 10 years impact of the Get Alarmed, NC! program and estimates the number of potential lives saved. We overlapped Get Alarmed, NC! program installation data with national information on fires using GIS to identify homes that experienced a fire after an alarm was installed and calculated potential lives saved based on program documentation and average housing occupancy. We found that using GIS was an efficient and quick way to match addresses from two distinct sources. From this approach we estimated that between 221 and 384 residents were potentially saved due to alarms installed in their homes by Get Alarmed, NC!. Compared with other program evaluations that require intensive and costly participant telephone surveys and/or in-person interviews, the GIS approach is inexpensive, quick, and can easily analyze large disparate datasets. In addition, it can be used to help target the areas most at risk from the onset. These benefits suggest that by incorporating previously unutilized data, the GIS approach has the potential for broader applications within public health program evaluation.

  13. 41 CFR 301-11.11 - How do I select lodging and make lodging reservations?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... always stay in a “fire safe” facility. This is a facility that meets the fire safety requirements of the Hotel and Motel Fire Safety Act of 1990 (the Act), as amended (see 5 U.S.C. 5707a). (c) When selecting a...

  14. 41 CFR 301-11.11 - How do I select lodging and make lodging reservations?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... always stay in a “fire safe” facility. This is a facility that meets the fire safety requirements of the Hotel and Motel Fire Safety Act of 1990 (the Act), as amended (see 5 U.S.C. 5707a). (c) When selecting a...

  15. 41 CFR 301-11.11 - How do I select lodging and make lodging reservations?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... always stay in a “fire safe” facility. This is a facility that meets the fire safety requirements of the Hotel and Motel Fire Safety Act of 1990 (the Act), as amended (see 5 U.S.C. 5707a). (c) When selecting a...

  16. 77 FR 17504 - Agency Information Collection Activities: Proposed Collection; Comments Requested: Notification...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-26

    ...: Notification to Fire Safety Authority of Storage of Explosive Materials. (3) Agency form number, if any, and... provided both orally and in writing to the authority having jurisdiction for fire safety in the locality in...] Agency Information Collection Activities: Proposed Collection; Comments Requested: Notification to Fire...

  17. 30 CFR 77.1913 - Fire-resistant wood.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Fire-resistant wood. 77.1913 Section 77.1913 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Shaft Sinking § 77.1913 Fire-resistant wood. Except for crossties, timbers, and other wood products...

  18. 30 CFR 77.1913 - Fire-resistant wood.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Fire-resistant wood. 77.1913 Section 77.1913 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Shaft Sinking § 77.1913 Fire-resistant wood. Except for crossties, timbers, and other wood products...

  19. 30 CFR 77.1913 - Fire-resistant wood.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Fire-resistant wood. 77.1913 Section 77.1913 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Shaft Sinking § 77.1913 Fire-resistant wood. Except for crossties, timbers, and other wood products...

  20. Fire and Life Safety Training Needs of Rail Rapid Transit System and Fire Service Personnel

    DOT National Transportation Integrated Search

    1983-05-01

    This report presents a summary and the results of the successful workshop "On Track to Fire and Life Safety in Rail Rapid Transit," held on August 2-4, 1982, at Crystal City, Virginia. Sponsored by the Urban Mass Transportation Administration (UMTA) ...

  1. 29 CFR 1910.39 - Fire prevention plans.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 5 2012-07-01 2012-07-01 false Fire prevention plans. 1910.39 Section 1910.39 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH STANDARDS Exit Routes and Emergency Planning § 1910.39 Fire prevention plans. (a...

  2. 24 CFR 232.620 - Determination of compliance by HHS.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... of Fire Safety Equipment Special Requirements § 232.620 Determination of compliance by HHS. An... the fire safety equipment has been installed, will be in compliance with the HHS requirements for fire... services along with a plan prepared by the applicant for correcting those deficiencies. In such event, HHS...

  3. 24 CFR 232.620 - Determination of compliance by HHS.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... of Fire Safety Equipment Special Requirements § 232.620 Determination of compliance by HHS. An... the fire safety equipment has been installed, will be in compliance with the HHS requirements for fire... services along with a plan prepared by the applicant for correcting those deficiencies. In such event, HHS...

  4. 30 CFR 77.1913 - Fire-resistant wood.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Fire-resistant wood. 77.1913 Section 77.1913 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Shaft Sinking § 77.1913 Fire-resistant wood. Except for crossties, timbers, and other wood products...

  5. 30 CFR 77.1913 - Fire-resistant wood.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fire-resistant wood. 77.1913 Section 77.1913 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH... Shaft Sinking § 77.1913 Fire-resistant wood. Except for crossties, timbers, and other wood products...

  6. Progress in Fire Detection and Suppression Technology for Future Space Missions

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Urban, David L.

    2000-01-01

    Fire intervention technology (detection and suppression) is a critical part of the strategy of spacecraft fire safety. This paper reviews the status, trends, and issues in fire intervention, particularly the technology applied to the protection of the International Space Station and future missions beyond Earth orbit. An important contribution to improvements in spacecraft fire safety is the understanding of the behavior of fires in the non-convective (microgravity) environment of Earth-orbiting and planetary-transit spacecraft. A key finding is the strong influence of ventilation flow on flame characteristics, flammability limits and flame suppression in microgravity. Knowledge of these flow effects will aid the development of effective processes for fire response and technology for fire suppression.

  7. 30 CFR 57.4430 - Surface storage facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....4430 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention... ignition sources to prevent fire or explosion; and (4) Vented or otherwise constructed to prevent...

  8. 30 CFR 57.4360 - Underground alarm systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....4360 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4360 Underground alarm systems. (a) Fire alarm...

  9. 30 CFR 57.4263 - Underground belt conveyors.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....4263 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Equipment § 57.4263 Underground belt conveyors. Fire protection shall be...

  10. 30 CFR 57.4203 - Extinguisher recharging or replacement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 57.4203 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Equipment § 57.4203 Extinguisher recharging or replacement. Fire...

  11. 30 CFR 56.4201 - Inspection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control... following schedules: (1) Fire extinguishers shall be inspected visually at least once a month to determine...

  12. 30 CFR 56.4203 - Extinguisher recharging or replacement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 56.4203 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Equipment § 56.4203 Extinguisher recharging or replacement. Fire...

  13. 30 CFR 57.4201 - Inspection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control... following schedules: (1) Fire extinguishers shall be inspected visually at least once a month to determine...

  14. 30 CFR 57.4200 - General requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Equipment § 57.4200 General requirements. (a) For fighting fires that could endanger...

  15. 30 CFR 56.4430 - Storage facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and... separated from ignition sources to prevent fire or explosion; and (4) Vented or otherwise constructed to...

  16. 30 CFR 56.4200 - General requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Equipment § 56.4200 General requirements. (a) For fighting fires that could endanger...

  17. 30 CFR 56.4104 - Combustible waste.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and... liquids, shall not accumulate in quantities that could create a fire hazard. (b) Until disposed of...

  18. 30 CFR 56.4104 - Combustible waste.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... properly, waste or rags containing flammable or combustible liquids that could create a fire hazard shall... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and...

  19. 30 CFR 56.4104 - Combustible waste.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... properly, waste or rags containing flammable or combustible liquids that could create a fire hazard shall... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and...

  20. 30 CFR 56.4104 - Combustible waste.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... properly, waste or rags containing flammable or combustible liquids that could create a fire hazard shall... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and...

  1. 30 CFR 56.4104 - Combustible waste.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... properly, waste or rags containing flammable or combustible liquids that could create a fire hazard shall... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and...

  2. Fire fighter fatalities 1998–2001: overview with an emphasis on structure related traumatic fatalities

    PubMed Central

    Hodous, T; Pizatella, T; Braddee, R; Castillo, D

    2004-01-01

    Objective: To review the causes of all fire fighter line-of-duty-deaths from 1998 through 2001, and present recommendations for preventing fatalities within the specific subgroup of structure related events. Methods: Fire fighter fatality data from the United States Fire Administration were reviewed and classified into three main categories of injury. Investigations conducted through the National Institute for Occupational Safety and Health (NIOSH) Fire Fighter Fatality Investigation and Prevention Program provided the basis for the recommendations presented in this paper. Results: During the time period from 1998–2001, there were 410 line-of-duty deaths among fire fighters in the United States, excluding the 343 fire fighters who died at the World Trade Center on 11 September 2001. The 410 fatalities included 191 medical (non-traumatic) deaths (47%), 75 motor vehicle related fatalities (18%), and 144 other traumatic fatalities (35%). The latter group included 68 fatalities that were associated with structures which commonly involved structural collapse, rapid fire progression, and trapped fire fighters. Conclusions: Structural fires pose particular hazards to fire fighters. Additional efforts must be directed to more effectively use what we have learned through the NIOSH investigations and recommendations from published experts in the safety community, consensus standards, and national fire safety organizations to reduce fire fighter fatalities during structural fire fighting. PMID:15314049

  3. OSHA safety requirements and the general duty clause.

    PubMed

    Mills, Anne C; Chillock, Cynthia A; Edelman, Harold; Mills, Shannon E

    2005-03-01

    Dental offices and clinics are subject to the same general safety requirements as other workplaces. Current guidelines, inspections, education, and training focus on infectious disease as the major workplace hazard for dental health care personnel (DHCP). However, the Occupational Safety and Health Administration has cited an increasing variety and number of general safety hazards during inspections of dental offices. A review of the general safety requirements for personal protective equipment and fire safety as they relate to DHCP follows. The authors discuss the responsibility of both employers and employees to perform workplace hazard evaluation and to implement education, engineering controls, and work practice controls to minimize their exposure to recognized and emerging workplace hazards.

  4. A job safety program for construction workers designed to reduce the potential for occupational injury using tool box training sessions and computer-assisted biofeedback stress management techniques.

    PubMed

    Johnson, Kenneth A; Ruppe, Joan

    2002-01-01

    This project was conducted with a multicultural construction company in Hawaii, USA. The job duties performed included drywall and carpentry work. The following objectives were selected for this project: (a) fire prevention training and inspection of first aid equipment; (b) blood-borne pathogen training and risk evaluation; (c) ergonomic and risk evaluation intervention program; (d) electrical safety training and inspection program; (e) slips, trips, and falls safety training; (f) stress assessment and Personal Profile System; (g) safety and health program survey; (h) improving employee relations and morale by emphasizing spirituality; and (i) computer-assisted biofeedback stress management training. Results of the project indicated that observed safety hazards, reported injuries, and levels of perceived stress. were reduced for the majority of the population.

  5. Application of fire and evacuation models in evaluation of fire safety in railway tunnels

    NASA Astrophysics Data System (ADS)

    Cábová, Kamila; Apeltauer, Tomáš; Okřinová, Petra; Wald, František

    2017-09-01

    The paper describes an application of numerical simulation of fire dynamics and evacuation of people in a tunnel. The software tool Fire Dynamics Simulator is used to simulate temperature resolution and development of smoke in a railway tunnel. Comparing to temperature curves which are usually used in the design stage results of the model show that the numerical model gives lower temperature of hot smoke layer. Outputs of the numerical simulation of fire also enable to improve models of evacuation of people during fires in tunnels. In the presented study the calculated high of smoke layer in the tunnel is in 10 min after the fire ignition lower than the level of 2.2 m which is considered as the maximal limit for safe evacuation. Simulation of the evacuation process in bigger scale together with fire dynamics can provide very valuable information about important security conditions like Available Safe Evacuation Time (ASET) vs Required Safe Evacuation Time (RSET). On given example in software EXODUS the paper summarizes selected results of evacuation model which should be in mind of a designer when preparing an evacuation plan.

  6. Preparedness of fire safety in underground train station: Comparison between train operators in Malaysia with other operators from the developed countries

    NASA Astrophysics Data System (ADS)

    Tajedi, Noor Aqilah A.; Sukor, Nur Sabahiah A.; Ismail, Mohd Ashraf M.; Shamsudin, Shahrul A.

    2017-10-01

    The purpose of this paper is to compare the fire evacuation plan and preparation at the underground train stations in the different countries. The methodology for this study was using the extended questionnaire survey to investigate the Rapid Rail Sdn Bhd, Malaysia's fire safety plan and preparation at the underground train stations. There were four sections in the questionnaire which included (i) background of the respondents, (ii) the details on the train stations, safety instruction and fire evacuation exercises (iii) technical systems, installation and equipment at the underground stations and (iv) procedures and technical changes related to fire safety that had been applied by the operators. Previously, the respondents from the different train operator services in the developed countries had completed the questionnaires. This paper extends the response from the Rapid Rail Sdn Bhd to compare the emergency procedures and preparation for fire event with the developed countries. As a result, this study found that the equipment and facilities that provided at the underground train stations that operated by Rapid Rail are relevant for fire safety procedures and needs. The main advantage for Rapid Rail is the underground stations were designed with two or more entrances/exits that may perform better evacuation compare to one main entrance/exit train stations in the other developed countries.

  7. Safety engineering in handling fuels and lubricants in civil aviation

    NASA Astrophysics Data System (ADS)

    Protoereiskii, Aleksandr Stepanovich

    The book is concerned with methods of improving working conditions, work hygiene, safety engineering, and fire and explosion prevention during the storage and handling of petroleum products at fuel and lubricant storage facilities. The discussion covers methods of protection against static and atmospheric discharges, lightning protection, safety engineering in fuel and lubricant laboratories, and methods of fire prevention and fire extinction. Attention is also given to methods for administering first aid in case of accidents and poisoning.

  8. National Conference on Campus Safety (15th, University of Vermont, Burlington, June 21-26, 1968).

    ERIC Educational Resources Information Center

    Green, Jack N., Ed.

    Presentations made at the fifteenth National Conference on Campus Safety. The following topics are dealt with--(1) Occupational Health on Campus, (2) Teacher Liability in School Accidents, (3) Indoctrinating Students in Fire Safety, (4) Computer Installations Safety and Fire Protection, (5) The Design of Laboratory Buildings, (6) A Uniform System…

  9. 30 CFR 57.4104 - Combustible waste.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and... liquids, shall not accumulate in quantities that could create a fire hazard. (b) Waste or rags containing...

  10. 30 CFR 57.4503 - Conveyor belt slippage.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and... within confined areas where evacuation would be restricted in the event of a fire resulting from belt...

  11. 30 CFR 57.4260 - Underground self-propelled equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 57.4260 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire... self-propelled equipment is used underground, a fire extinguisher shall be on the equipment. This...

  12. 30 CFR 57.4361 - Underground evacuation drills.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 57.4361 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire...) Involve activation of the fire alarm system; and (3) Include evacuation of all persons from their work...

  13. 30 CFR 57.4261 - Shaft-station waterlines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....4261 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention... located at underground shaft stations and are part of the mine's fire protection system shall have at...

  14. 30 CFR 57.4761 - Underground shops.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and... toxic gases from a fire originating in an underground shop where maintenance work is routinely done on...

  15. 30 CFR 56.4503 - Conveyor belt slippage.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and... confined areas where evacuation would be restricted in the event of a fire resulting from belt-slippage...

  16. 30 CFR 57.4505 - Fuel lines to underground areas.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 57.4505 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire... shotcrete, one-half inch of gunite, or other noncombustible material with equivalent fire protection...

  17. 30 CFR 57.4104 - Combustible waste.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... flammable or combustible liquids that could create a fire hazard shall be placed in the following containers... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and...

  18. 30 CFR 57.4104 - Combustible waste.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... flammable or combustible liquids that could create a fire hazard shall be placed in the following containers... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and...

  19. 30 CFR 57.4104 - Combustible waste.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... flammable or combustible liquids that could create a fire hazard shall be placed in the following containers... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and...

  20. 30 CFR 57.4104 - Combustible waste.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... flammable or combustible liquids that could create a fire hazard shall be placed in the following containers... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and...

  1. Infrared-fiber-optic fire sensor developments - Role of measurement uncertainty in evaluation of background limited range. [in spacecraft safety

    NASA Technical Reports Server (NTRS)

    Tapphorn, Ralph M.; Kays, Randy; Porter, Alan

    1989-01-01

    Fire-detector systems based on distributed infrared fiber-sensors have been investigated for potential applications in the aerospace industry. Responsivities to blackbody and flame radiations were measured with various design configurations of an infrared fiber-optic sensor. Signal processing techniques were also investigated, and the results show significant differences in the fire-sensor performance depending on the design configuration. Measurement uncertainties were used to determine the background-limited ranges for the various fire-sensor concepts, and the probability of producing false alarms caused by fluctuations in the background signals were determined using extreme probability theory. The results of the research show that infrared fiber-optic fire sensors are feasible for application on manned spacecraft; however, additional development work will be required to eliminate false alarms caused by high temperature objects such as incandescent lamps.

  2. A GIS-based approach for comparative analysis of potential fire risk assessment

    NASA Astrophysics Data System (ADS)

    Sun, Ying; Hu, Lieqiu; Liu, Huiping

    2007-06-01

    Urban fires are one of the most important sources of property loss and human casualty and therefore it is necessary to assess the potential fire risk with consideration of urban community safety. Two evaluation models are proposed, both of which are integrated with GIS. One is the single factor model concerning the accessibility of fire passage and the other is grey clustering approach based on the multifactor system. In the latter model, fourteen factors are introduced and divided into four categories involving security management, evacuation facility, construction resistance and fire fighting capability. A case study on campus of Beijing Normal University is presented to express the potential risk assessment models in details. A comparative analysis of the two models is carried out to validate the accuracy. The results are approximately consistent with each other. Moreover, modeling with GIS promotes the efficiency the potential risk assessment.

  3. Prevention of 3 "never events" in the operating room: fires, gossypiboma, and wrong-site surgery.

    PubMed

    Zahiri, Hamid R; Stromberg, Jeffrey; Skupsky, Hadas; Knepp, Erin K; Folstein, Matthew; Silverman, Ronald; Singh, Devinder

    2011-03-01

    This study sought to identify and provide preventative recommendations for potentially devastating safety violations in the operating room. A Medline database search from 1950 to current using the terms patient safety and operating room was conducted. All topics identified were reviewed. Three patient safety violations with potential for immediate and devastating outcomes were selected for discussion using evidence-based literature. The search identified 2851 articles, 807 of which were directly related to patient safety in the operating room. Topics addressed by these 807 included infectious complications (26%), fires (11%), communication/teamwork (6%), retained foreign objects (3%), safety checklists (1%), and wrong-site surgery (1%). Fires, gossypiboma, and wrong-site surgery were selected for discussion. Although fire, gossypiboma, and wrong-site surgery should be "never events" in the operating room, they continue to persist as 3 common patient safety violations. This study provides the epidemiology, common etiologies, and evidence-based preventative recommendations for each.

  4. 24 CFR 232.515 - Refund of fees.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... FACILITIES Eligibility Requirements-Supplemental Loans To Finance Purchase and Installation of Fire Safety... that the installation of fire safety equipment for the project has been prevented because of...

  5. 24 CFR 232.515 - Refund of fees.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... FACILITIES Eligibility Requirements-Supplemental Loans To Finance Purchase and Installation of Fire Safety... that the installation of fire safety equipment for the project has been prevented because of...

  6. 24 CFR 232.515 - Refund of fees.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... FACILITIES Eligibility Requirements-Supplemental Loans To Finance Purchase and Installation of Fire Safety... that the installation of fire safety equipment for the project has been prevented because of...

  7. School Fire Safety. Bulletin, 1951, No. 13

    ERIC Educational Resources Information Center

    Viles, N. E.

    1951-01-01

    School fires endanger pupils' lives and take annually a heavy toll in school property losses. If not controlled, these potentials may be changed quickly into serious losses. School officials, teachers, parents, and the public have an interest in school fire safety. Because of other interests and a lack of assigned responsibility in this area fire…

  8. 30 CFR 57.4531 - Surface flammable or combustible liquid storage buildings or rooms.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Installation/construction/maintenance § 57.4531 Surface... fire resistance rating of at least one hour; or (2) Equipped with an automatic fire supression system...

  9. 41 CFR 102-80.125 - Who has the responsibility for determining the acceptability of each equivalent level of safety...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... departments or other local authorities for use in developing pre-fire plans. ... Fire Prevention Equivalent Level of Safety Analysis § 102-80.125 Who has the responsibility for... acceptability must include a review of the fire protection engineer's qualifications, the appropriateness of the...

  10. 41 CFR 102-80.125 - Who has the responsibility for determining the acceptability of each equivalent level of safety...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... departments or other local authorities for use in developing pre-fire plans. ... Fire Prevention Equivalent Level of Safety Analysis § 102-80.125 Who has the responsibility for... acceptability must include a review of the fire protection engineer's qualifications, the appropriateness of the...

  11. 41 CFR 102-80.125 - Who has the responsibility for determining the acceptability of each equivalent level of safety...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... departments or other local authorities for use in developing pre-fire plans. ... Fire Prevention Equivalent Level of Safety Analysis § 102-80.125 Who has the responsibility for... acceptability must include a review of the fire protection engineer's qualifications, the appropriateness of the...

  12. 41 CFR 102-80.125 - Who has the responsibility for determining the acceptability of each equivalent level of safety...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... departments or other local authorities for use in developing pre-fire plans. ... Fire Prevention Equivalent Level of Safety Analysis § 102-80.125 Who has the responsibility for... acceptability must include a review of the fire protection engineer's qualifications, the appropriateness of the...

  13. 41 CFR 102-80.125 - Who has the responsibility for determining the acceptability of each equivalent level of safety...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... departments or other local authorities for use in developing pre-fire plans. ... Fire Prevention Equivalent Level of Safety Analysis § 102-80.125 Who has the responsibility for... acceptability must include a review of the fire protection engineer's qualifications, the appropriateness of the...

  14. 24 CFR 3280.206 - Fireblocking.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.206 Fireblocking. (a... materials: (1) Minimum one inch nominal lumber, 5/16 inch thick gypsum board, or equivalent fire resistive...

  15. 24 CFR 3280.206 - Fireblocking.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.206 Fireblocking. (a... materials: (1) Minimum one inch nominal lumber, 5/16 inch thick gypsum board, or equivalent fire resistive...

  16. 24 CFR 3280.206 - Fireblocking.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.206 Fireblocking. (a... materials: (1) Minimum one inch nominal lumber, 5/16 inch thick gypsum board, or equivalent fire resistive...

  17. 24 CFR 3280.206 - Fireblocking.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.206 Fireblocking. (a... materials: (1) Minimum one inch nominal lumber, 5/16 inch thick gypsum board, or equivalent fire resistive...

  18. 24 CFR 3280.206 - Fireblocking.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... DEVELOPMENT MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS Fire Safety § 3280.206 Fireblocking. (a... materials: (1) Minimum one inch nominal lumber, 5/16 inch thick gypsum board, or equivalent fire resistive...

  19. NASA technical advances in aircraft occupant safety. [clear air turbulence detectors, fire resistant materials, and crashworthiness

    NASA Technical Reports Server (NTRS)

    Enders, J. H.

    1978-01-01

    NASA's aviation safety technology program examines specific safety problems associated with atmospheric hazards, crash-fire survival, control of aircraft on runways, human factors, terminal area operations hazards, and accident factors simulation. While aircraft occupants are ultimately affected by any of these hazards, their well-being is immediately impacted by three specific events: unexpected turbulence encounters, fire and its effects, and crash impact. NASA research in the application of laser technology to the problem of clear air turbulence detection, the development of fire resistant materials for aircraft construction, and to the improvement of seats and restraint systems to reduce crash injuries are reviewed.

  20. Fire safety practices in the Shuttle and the Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1993-01-01

    The Shuttle reinforces its policy of fire-preventive measures with onboard smoke detectors and Halon 1301 fire extinguishers. The forthcoming Space Station Freedom will have expanded fire protection with photoelectric smoke detectors, radiation flame detectors, and both fixed and portable carbon dioxide fire extinguishers. Many design and operational issues remain to be resolved for Freedom. In particular, the fire-suppression designs must consider the problems of gas leakage in toxic concentrations, alternative systems for single-failure redundancy, and commonality with the corresponding systems of the Freedom international partners. While physical and engineering requirements remain the primary driving forces for spacecraft fire-safety technology, there are, nevertheless, needs and opportunities for the application of microgravity combustion knowledge to improve and optimize the fire-protective systems.

  1. Safety, Health, and Fire Prevention Guide for Hospital Safety Managers

    DTIC Science & Technology

    1993-03-01

    Safety committee S 2-5 Oxygen quality assurance program 0 2-6 Safety and fire prevention library 0 2-7 Safety services to Dental Activities • 2-8...Chapter 2 Safety Management 2-1. Safety policy statement Health Services Command (HSC) Supplement (Suppl) 1 to Army Regulation (AR) 385-10 and the...Management. (b) The medical staff. (c) The nursing service . (d) Logistics. (e) Nutritional care. (f) Preventive medicine. * 2-3 USAEHA TG No. 152 March 1993 (g

  2. Fire!

    ERIC Educational Resources Information Center

    Jones, Rebecca

    1996-01-01

    The number of school fires is up nationwide. This article describes unsafe school conditions, problems with new fire codes, and the factors that contribute to school fires. Installation of sprinkler systems is recommended. A fire-safety checklist is included. (LMI)

  3. 46 CFR 160.135-3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., the term: Commandant means the Chief of the Lifesaving and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety Division, U.S. Coast Guard Stop 7509, 2703 Martin... the position before displacement. SOLAS means the International Convention for the Safety of Life at...

  4. 46 CFR 160.135-3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., the term: Commandant means the Chief of the Lifesaving and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety Division, U.S. Coast Guard Stop 7509, 2703 Martin... the position before displacement. SOLAS means the International Convention for the Safety of Life at...

  5. 49 CFR 192.171 - Compressor stations: Additional safety equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Compressor stations: Additional safety equipment... Pipeline Components § 192.171 Compressor stations: Additional safety equipment. (a) Each compressor station must have adequate fire protection facilities. If fire pumps are a part of these facilities, their...

  6. 30 CFR 57.4501 - Fuel lines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control... stopping the flow of fuel at the source and shall be located and maintained to minimize fire hazards. This...

  7. 30 CFR 57.4533 - Mine opening vicinity.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and... materials; or (b) Constructed to meet a fire resistance rating of no less than one hour; or (c) Provided...

  8. 30 CFR 56.4102 - Spillage and leakage.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and... liquid spillage or leakage shall be removed in a timely manner or controlled to prevent a fire hazard. ...

  9. 30 CFR 57.4363 - Underground evacuation instruction.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 57.4363 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire... and evacuation plans and procedures and fire warning signals in effect at the mine. (b) Whenever a...

  10. 30 CFR 57.4102 - Spillage and leakage.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and... liquid spillage or leakage shall be removed in a timely manner or controlled to prevent a fire hazard. ...

  11. 30 CFR 56.4501 - Fuel lines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control... stopping the flow of fuel at the source and shall be located and maintained to minimize fire hazards. This...

  12. 30 CFR 56.4230 - Self-propelled equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....4230 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Equipment § 56.4230 Self-propelled equipment. (a)(1) Whenever a fire or its effects...

  13. 30 CFR 77.1100 - Fire protection; training and organization.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....1100 Section 77.1100 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF... facilities and equipment shall be provided commensurate with the potential fire hazards at each structure...

  14. Flame Resistant Fibrous Materials Development

    NASA Technical Reports Server (NTRS)

    Coskren, R. J.

    1982-01-01

    Since 1973, Albany International Research Co. has been engaged by NASA-JSC under Contract No. NAS9-13673 to conduct studies aimed at developing fibers and flexible structures made therefrom which would provide improved flame resistance over existing commercially available materials in oxygen enriched atmospheres. A portion of the crew bay area life support system and crew equipment for the space shuttle was initially designed to function at a 30% oxygen, 70% nitrogen atmosphere at 9 psia pressure. This oxygen concentration imposed certain fire safety and smoke generation requirements which could not be completely met by commonly accepted textiles. Potentially useful new polymers were investigated both for fire safety and mechanical properties. During the course of the work, three candidate fibers were studied and evaluated and the results of each of these efforts are summarized.

  15. Nursing students practice primary fire prevention.

    PubMed

    Lehna, Carlee; Todd, Julie A; Keller, Rachel; Presley, Lynn; Jackson, Jessica; Davis, Stephanie; Hockman, Kristi; Phillips-Payne, Charles; Sauer, Sarah; Wessemeier, Sarah

    2013-09-01

    The purpose of this project was to evaluate a standardized, interactive, home fire safety program for elementary school students. Senior baccalaureate nursing students in their pediatric clinical rotation taught burn prevention techniques using Hazard House, a model house filled with common household fire hazards (Hazard House, 2006, Ref. 1). Elementary school students were encouraged to identify the hazards and discuss ways in which the house could be made safer. Local firemen then briefly presented what to do if a fire occurred, how firemen may look during a rescue, and the importance of working smoke alarms in the home. A pretest-posttest design was used to examine the effectiveness of an educational intervention. The three groups of participants included 128 kindergarten students, 311 students in grades 1-2, and 61 students in grades 3-4. The tests and interventions were tailored appropriately for each age group. There was no difference in pre- and post-test scores for the students in kindergarten and grades 3-4 (p>0.05). However, there was a significant difference for students in grades 1-2 (p<0.001). It is important for nurses to assess for and teach about fire injury prevention to prevent potentially devastating irreversible injuries. The results suggest that the educational intervention was effective in improving the understanding of fire safety for students in grades 1-2. Future studies may need to include a larger sample of students for the other grades. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.

  16. An assessment of three different fire resistance tests for hydraulic fluids

    NASA Astrophysics Data System (ADS)

    Loftus, J. J.

    1981-10-01

    The Center for Fire Research at the National Bureau of Standards at the request of the Mine Safety and Health Administration (MSHA) and the Bureau of Mines made an evaluation or assessment of the three different flammability tests used by MSHA for measuring the fire resistance of hydraulic fluids intended for use in underground coal mining operations. The methods described in the Code of Federal Regulations Schedule 30, Part 35, consist of the following: an Autogenous Ignition Temperature Test, a Temperature-Pressure Spray Ignition Test, and a Test to Determine the Effect of Evaporation on the Flammability of Hydraulic Fluids. Recommendations for improvement of the three test procedures are provided.

  17. 24 CFR 232.605 - Contract requirements.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Fire Safety Equipment Form of Contract § 232.605 Contract requirements. (a) The contract between the... contract. Either form of contract shall include the cost of fire safety equipment, its installation, and...

  18. 24 CFR 232.605 - Contract requirements.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Fire Safety Equipment Form of Contract § 232.605 Contract requirements. (a) The contract between the... contract. Either form of contract shall include the cost of fire safety equipment, its installation, and...

  19. 24 CFR 232.605 - Contract requirements.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Fire Safety Equipment Form of Contract § 232.605 Contract requirements. (a) The contract between the... contract. Either form of contract shall include the cost of fire safety equipment, its installation, and...

  20. Fight Fire Without Fire Fighters!

    ERIC Educational Resources Information Center

    Peacock, Richard D.

    1977-01-01

    There is a role for the classroom teacher in teaching fire safety. Discusses the inadequacies of present fire prevention programs and provides ten specific steps teachers can take to avoid suffering and death from fire. (Author/RK)

  1. 46 CFR 160.132-3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...), in this subpart, the term: Commandant means the Chief of the Lifesaving and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety Division, U.S. Coast Guard Stop... described. SOLAS means the International Convention for the Safety of Life at Sea, 1974, as amended. [USCG...

  2. 46 CFR 160.151-3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... subpart, the term: Commandant means the Chief of the Lifesaving and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety Division, U.S. Coast Guard Stop 7509...-57. SOLAS means the International Convention for the Safety of Life at Sea, 1974, as amended by the...

  3. 46 CFR 160.132-3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...), in this subpart, the term: Commandant means the Chief of the Lifesaving and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety Division, U.S. Coast Guard Stop... described. SOLAS means the International Convention for the Safety of Life at Sea, 1974, as amended. [USCG...

  4. 46 CFR 160.151-3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... subpart, the term: Commandant means the Chief of the Lifesaving and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety Division, U.S. Coast Guard Stop 7509...-57. SOLAS means the International Convention for the Safety of Life at Sea, 1974, as amended by the...

  5. 46 CFR 160.133-3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Chief of the Lifesaving and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety Division, U.S. Coast Guard Stop 7509, 2703 Martin Luther King Jr. Avenue SE... International Convention for the Safety of Life at Sea, 1974, as amended. [USCG-2010-0048, 76 FR 62983, Oct. 11...

  6. 46 CFR 160.115-3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...), in this subpart, the term: Commandant means the Chief of the Lifesaving and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety Division, U.S. Coast Guard Stop... described. SOLAS means the International Convention for the Safety of Life at Sea, 1974, as amended. [USCG...

  7. 46 CFR 160.115-3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...), in this subpart, the term: Commandant means the Chief of the Lifesaving and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety Division, U.S. Coast Guard Stop... described. SOLAS means the International Convention for the Safety of Life at Sea, 1974, as amended. [USCG...

  8. 49 CFR 192.171 - Compressor stations: Additional safety equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Design of... must have adequate fire protection facilities. If fire pumps are a part of these facilities, their... event of inadequate cooling or lubrication of the unit. (d) Each compressor station gas engine that...

  9. 30 CFR 57.4100 - Smoking and use of open flames.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 57.4100 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire... flammable gases are— (a) Used or transported in a manner that could create a fire hazard; or (b) Stored or...

  10. 30 CFR Appendix I to Subpart C of... - National Consensus Standards

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Subpart C of Part 56 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire... Standards Mine operators seeking further information in the area of fire prevention and control may consult...

  11. 30 CFR 56.4100 - Smoking and use of open flames.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 56.4100 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire... flammable gases are— (a) Used or transported in a manner that could create a fire hazard; or (b) Stored or...

  12. 30 CFR 75.341 - Direct-fired intake air heaters.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 75.341 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.341 Direct-fired intake air heaters. (a) If any system used to heat intake air malfunctions, the heaters affected shall switch...

  13. 41 CFR 102-80.115 - Is there more than one option for establishing that an equivalent level of safety exists?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., complete sprinkler protection can be expected to prevent flashover in the room of fire origin, limit fire... the times required for egress. If a combination of fire protection systems provides a margin of safety... Contracts and Property Management Federal Property Management Regulations System (Continued) FEDERAL...

  14. 41 CFR 102-80.115 - Is there more than one option for establishing that an equivalent level of safety exists?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., complete sprinkler protection can be expected to prevent flashover in the room of fire origin, limit fire... the times required for egress. If a combination of fire protection systems provides a margin of safety... Contracts and Property Management Federal Property Management Regulations System (Continued) FEDERAL...

  15. 41 CFR 102-80.115 - Is there more than one option for establishing that an equivalent level of safety exists?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., complete sprinkler protection can be expected to prevent flashover in the room of fire origin, limit fire... the times required for egress. If a combination of fire protection systems provides a margin of safety... Contracts and Property Management Federal Property Management Regulations System (Continued) FEDERAL...

  16. 41 CFR 102-80.115 - Is there more than one option for establishing that an equivalent level of safety exists?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., complete sprinkler protection can be expected to prevent flashover in the room of fire origin, limit fire... the times required for egress. If a combination of fire protection systems provides a margin of safety... Contracts and Property Management Federal Property Management Regulations System (Continued) FEDERAL...

  17. Fire Prevention and Emergency Procedures. Module SH-05. Safety and Health.

    ERIC Educational Resources Information Center

    Center for Occupational Research and Development, Inc., Waco, TX.

    This student module on fire prevention and emergency procedures is one of 50 modules concerned with job safety and health. This module discusses the chemistry of fire and the methods for extinguishment, along with the steps necessary for emergency action. Following the introduction, 10 objectives (each keyed to a page in the text) the student is…

  18. 38 CFR 17.81 - Contracts for residential treatment services for veterans with alcohol or drug dependence or...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Meet fire safety requirements as follows: (i) The building must meet the requirements in the applicable...) Portable fire extinguishers shall be installed, inspected, and maintained in accordance with NFPA 10... 101. (vi) An annual fire and safety inspection shall be conducted at the halfway house or residential...

  19. 38 CFR 17.81 - Contracts for residential treatment services for veterans with alcohol or drug dependence or...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Meet fire safety requirements as follows: (i) The building must meet the requirements in the applicable...) Portable fire extinguishers shall be installed, inspected, and maintained in accordance with NFPA 10... 101. (vi) An annual fire and safety inspection shall be conducted at the halfway house or residential...

  20. An assessment of the impact of home safety assessments on fires and fire-related injuries: a case study of Cheshire Fire and Rescue Service.

    PubMed

    Arch, B N; Thurston, M N

    2013-06-01

    Deaths and injuries related to fires are largely preventable events. In the UK, a plethora of community-based fire safety initiatives have been introduced over the last 25 years, often led by fire and rescue services, to address this issue. This paper focuses on one such initiative--home safety assessments (HSAs). Cheshire Fire and Rescue Service (in England) implemented a uniquely large-scale HSA intervention. This paper assesses its effectiveness. The impact of HSAs was assessed in relation to three outcomes: accidental dwelling fires (ADFs), ADFs contained and injuries arising from ADFs. A two-period comparison in fire-related rates of incidences in Cheshire between 2002 and 2011 was implemented, using Poisson regression and adjusting for the national temporal trend using a control group comprising the 37 other English non-metropolitan fire-services. Significant reductions were observed in rates of ADFs [incidence rate ratios (IRR): 0.79, 95% confidence interval (CI): 0.74-0.83, P < 0.001, 2002/03-2007/08 versus 2008/09-2010/11] and associated injuries (IRR: 0.49, 95% CI: 0.39-0.60, P < 0.001, 2002/03-2006/07 versus 2007/08-2010/11), but not in the proportion of fires contained to room of origin. There is strong evidence to suggest that the intervention was successful in reducing domestic fires and related injuries.

  1. 24 CFR 232.570 - Endorsement of credit instrument.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... of Fire Safety Equipment Eligible Security Instruments § 232.570 Endorsement of credit instrument.... (c) Statement by the Secretary of Health and Human Services that the fire safety equipment noted in...

  2. 24 CFR 232.570 - Endorsement of credit instrument.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... of Fire Safety Equipment Eligible Security Instruments § 232.570 Endorsement of credit instrument.... (c) Statement by the Secretary of Health and Human Services that the fire safety equipment noted in...

  3. 24 CFR 232.570 - Endorsement of credit instrument.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... of Fire Safety Equipment Eligible Security Instruments § 232.570 Endorsement of credit instrument.... (c) Statement by the Secretary of Health and Human Services that the fire safety equipment noted in...

  4. Expert systems applied to spacecraft fire safety

    NASA Technical Reports Server (NTRS)

    Smith, Richard L.; Kashiwagi, Takashi

    1989-01-01

    Expert systems are problem-solving programs that combine a knowledge base and a reasoning mechanism to simulate a human expert. The development of an expert system to manage fire safety in spacecraft, in particular the NASA Space Station Freedom, is difficult but clearly advantageous in the long-term. Some needs in low-gravity flammability characteristics, ventilating-flow effects, fire detection, fire extinguishment, and decision models, all necessary to establish the knowledge base for an expert system, are discussed.

  5. Wildfires

    MedlinePlus

    ... motels Expand sub-navigation Hotel fire safety tips Marijuana grow & extraction facilities Nightclubs and other assembly occupancies ... Fire behavior research Fire loss and injury research Benefits of home fire sprinklers Expand sub-navigation Environmental ...

  6. Risk factors for rural residential fires.

    PubMed

    Allareddy, Veerasathpurush; Peek-Asa, Corinne; Yang, Jingzhen; Zwerling, Craig

    2007-01-01

    Rural households report high fire-related mortality and injury rates, but few studies have examined the risk factors for fires. This study aims to identify occupant and household characteristics that are associated with residential fires in a rural cohort. Of 1,005 households contacted in a single rural county, 691 (68.8%) agreed to participate. One household with missing information on a reported fire was excluded from the analysis. We used logistic regression to examine the independent association of occupant and household characteristics with reported fires, controlling for years lived in the residence. We also examined the association between the occurrence of previous fires and the adoption of safety measures. A total of 78 (11.3%) households reported a residential fire. Occupant characteristics that were associated with significantly higher odds of reported fires included the presence of an occupant with alcohol problems (OR = 1.82, 95% CI = 1.01-3.28) and being married (OR = 2.11, 95% CI = 1.14-3.91). Rural farm households were associated with significantly higher odds (OR = 1.72, 95% CI = 1.01-2.93) of reporting a fire when compared to residences in towns, after controlling for all other occupant and household characteristics. The presence of a fire extinguisher (OR = 2.00, 95% CI = 1.10-3.64) was the only fire safety measure that had a statistically significant association with reported fire. Rural farm households report higher incidences of fire when compared to households located in towns. Experiencing a fire is not associated with an increased likelihood of adopting safety measures to prevent injuries once a fire has started.

  7. Demonstration of Spacecraft Fire Safety Technology

    NASA Technical Reports Server (NTRS)

    Ruff, Gary A.; Urban, David L.

    2012-01-01

    During the Constellation Program, the development of spacecraft fire safety technologies were focused on the immediate questions related to the atmosphere of the habitable volume and implementation of fire detection, suppression, and postfire clean-up systems into the vehicle architectures. One of the difficulties encountered during the trade studies for these systems was the frequent lack of data regarding the performance of a technology, such as a water mist fire suppression system or an optically-based combustion product monitor. Even though a spacecraft fire safety technology development project was being funded, there was insufficient time and funding to address all the issues as they were identified. At the conclusion of the Constellation Program, these knowledge gaps formed the basis for a project proposed to the Advanced Exploration Systems (AES) Program. This project, subsequently funded by the AES Program and in operation since October 2011, has as its cornerstone the development of an experiment to be conducted on an ISS resupply vehicle, such as the European Space Agency (ESA) Automated Transfer Vehicle (ATV) or Orbital Science s Cygnus vehicle after it leaves the ISS and before it enters the atmosphere. The technology development efforts being conducted in this project include continued quantification of low- and partial-gravity maximum oxygen concentrations of spacecraft-relevant materials, development and verification of sensors for fire detection and post-fire monitoring, development of standards for sizing and selecting spacecraft fire suppression systems, and demonstration of post-fire cleanup strategies. The major technology development efforts are identified in this paper but its primary purpose is to describe the spacecraft fire safety demonstration being planned for the reentry vehicle.

  8. Fire and the Design of Educational Buildings. Building Bulletin 7. Sixth Edition.

    ERIC Educational Resources Information Center

    Department of Education and Science, London (England).

    This bulletin offers guidance on English school premises regulations applying to safety protection against fires in the following general areas: means of escape in case of fire; precautionary measures to prevent fire; fire warning systems and fire fighting; fire spreading speed; structures and materials resistant to fires; and damage control. It…

  9. The estimation of electrical cable fire-induced damage limits

    NASA Astrophysics Data System (ADS)

    Nowlen, S. P.; Jacobus, M. J.

    Sandia National Laboratories has, for several years, been engaged in the performance of both fire safety and electrical equipment qualification research under independent programs sponsored by the US Nuclear Regulatory Commission. Recent comparisons between electrical cable thermal damageability data gathered independently in these two efforts indicate that a direct correlation exists between certain of the recent cable thermal vulnerability information gathered under equipment qualification conditions and thermal damageability in a fire environment. This direct correlation allows for a significant expansion of the data base on estimated cable thermal vulnerability limits in a fire environment because of the wide range of cable types and products that have been evaluated as a part of the equipment qualification research. This paper provides a discussion of the basis for the derived correlation, and presents estimated cable thermal damage limits for a wide range of generic cable types and specific cable products. The supposition that a direct correlation exists is supported through direct comparisons of the test results for certain specific cable products. The proposed supplemental cable fire vulnerability data gained from examination of the equipment qualification results is presented. These results should be of particular interest to those engaged in the evaluation of fire risk for industrial facilities, including nuclear power plants.

  10. Counting the cost of false alarms.

    PubMed

    2013-05-01

    While fire and rescue service personnel, the Government, those responsible for fire safety in the healthcare sector, the Health and Safety Executive, fire and rescue services, and indeed fire alarm and detection equipment manufacturers, must be pleased that the number of false fire alarms continues to fall, fire services still attended just under 585,000 fires or false alarm incidents across Great Britain in 2011/12. Of this total, 272,000 were actual fires, of which around 24,000 were in premises classified by the Department for Communities and Local Government (DCLG) as 'other buildings', i.e. not 'dwellings', a category that includes healthcare facilities (representing a 4% fall on 2010-2011). HEJ looks behind the statistics, and at the possibility that some fire services could, in future, charge healthcare providers that persistently report incidents that turn out to be false alarms.

  11. Fire behavior and risk analysis in spacecraft

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Sacksteder, Kurt R.

    1988-01-01

    Practical risk management for present and future spacecraft, including space stations, involves the optimization of residual risks balanced by the spacecraft operational, technological, and economic limitations. Spacecraft fire safety is approached through three strategies, in order of risk: (1) control of fire-causing elements, through exclusion of flammable materials for example; (2) response to incipient fires through detection and alarm; and (3) recovery of normal conditions through extinguishment and cleanup. Present understanding of combustion in low gravity is that, compared to normal gravity behavior, fire hazards may be reduced by the absence of buoyant gas flows yet at the same time increased by ventilation flows and hot particle expulsion. This paper discusses the application of low-gravity combustion knowledge and appropriate aircraft analogies to fire detection, fire fighting, and fire-safety decisions for eventual fire-risk management and optimization in spacecraft.

  12. Reported fire safety and first-aid amenities in Airbnb venues in 16 American cities.

    PubMed

    Kennedy, Hudson R; Jones, Vanya C; Gielen, Andrea

    2018-05-07

    Airbnb helps hosts rent all or part of their home to guests as an alternative to traditional hospitality settings. Airbnb venues are not uniformly regulated across the USA. This study quantified the reported prevalence of fire safety and first-aid amenities in Airbnb venues in the USA. The sample includes 120 691 venues in 16 US cities. Proportions of host-reported smoke and carbon monoxide (CO) detectors, fire extinguishers and first-aid kits were calculated. The proportion of venues that reportedly contained amenities are as follows: smoke detectors 80% (n=96 087), CO detectors 57.5% (n=69 346), fire extinguishers 42% (n=50 884) and first-aid kits 36% (n=43 497). Among this sample of Airbnb venues, safety deficiencies were noted. While most venues had smoke alarms, approximately 1/2 had CO alarms and less than 1/2 reported having a fire extinguishers or first-aid kits. Local and state governments or Airbnb must implement regulations compliant with current National Fire Protection Association fire safety standards. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  13. 46 CFR 160.076-5 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Definitions. As used in this part: Commandant means the Chief of the Lifesaving and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety Division, U.S. Coast Guard Stop...

  14. 46 CFR 160.076-5 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Definitions. As used in this part: Commandant means the Chief of the Lifesaving and Fire Safety Standards Division, Life Saving and Fire Safety Division: Commandant (CG-ENG-4), U.S. Coast Guard Headquarters, 2100...

  15. 46 CFR 160.076-5 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Definitions. As used in this part: Commandant means the Chief of the Lifesaving and Fire Safety Standards Division. Address: Commandant (CG-ENG-4), Attn: Lifesaving and Fire Safety Division, U.S. Coast Guard Stop...

  16. Fire Safety Training with Adults Who Are Profoundly Mentally Retarded.

    ERIC Educational Resources Information Center

    Rae, Rosamond; Roll, David

    1985-01-01

    An intensive fire safety training program for profoundly mentally retarded institutionalized persons resulted in a significant decrease in mean evacuation time and gradual substitution of verbal for physical prompts. (CL)

  17. Climate change and wildland firefighter health and safety.

    PubMed

    Withen, Patrick

    2015-02-01

    The author examines how climate change is impacting wildland firefighters. Climate change has made wildland fires more frequent and more intense. The increase in frequency and intensity of fires has pushed the number of fatalities and injuries higher in recent decades. The most common hazards on fires follow the trend of fire in general in that these hazards become more frequent and intense. Burnovers, heat exhaustion, tree hazards, and many other common fire hazards are more likely. The fire suppression agencies are making every effort to improve health and safety on fires by improving communication, weather forecasting, mapping, fire shelters, decision making and more. Despite these efforts, wildfires are becoming ever more hazardous because of climate change and the increasing frequency and intensity of wildfires. © 2015 SAGE Publications.

  18. Total Approach to Fire Safety.

    ERIC Educational Resources Information Center

    Burgener, Edward

    1979-01-01

    A study completed by the fire department of the City of Winnipeg has documented the effectiveness of smoke detectors in reducing fire losses. The entire Winnipeg fire prevention program is described. (MLF)

  19. 29 CFR Appendix A to Subpart L of... - Fire Protection

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the International Fire Service Training Association, the National Fire Protection Association (NFPA-1041), the International Society of Fire Service Instructors and other fire training sources be... planning, and safety practices. It is again suggested that fire service training sources be consulted for...

  20. Application of the Life Safety Code to a Historic Test Stand

    NASA Technical Reports Server (NTRS)

    Askins, Bruce; Lemke, Paul R.; Lewis, William L.; Covell, Carol C.

    2011-01-01

    NASA has conducted a study to assess alternatives to refurbishing existing launch vehicle modal test facilities as opposed to developing new test facilities to meet the demands of a very fiscally constrained test and evaluation environment. The results of this study showed that Marshall Space Flight Center (MSFC) Test Stand (TS) 4550 could be made compliant, within reasonable cost and schedule impacts, if safety processes and operational limitations were put in place to meet the safety codes and concerns of the Fire Marshall. Trades were performed with key selection criteria to ensure that appropriate levels of occupant safety are incorporated into test facility design modifications. In preparation for the ground vibration tests that were to be performed on the Ares I launch vehicle, the Ares Flight and Integrated Test Office (FITO) organization evaluated the available test facility options, which included the existing mothballed structural dynamic TS4550 used by Apollo and Shuttle, alternative ground vibration test facilities at other locations, and construction of a new dynamic test stand. After an exhaustive assessment of the alternatives, the results favored modifying the TS4550 because it was the lowest cost option and presented the least schedule risk to the NASA Constellation Program for Ares Integrated Vehicle Ground Vibration Test (IVGVT). As the renovation design plans and drawings were being developed for TS4550, a safety concern was discovered the original design for the construction of the test stand, originally built for the Apollo Program and renovated for the Shuttle Program, was completed before NASA s adoption of the currently imposed safety and building codes per National Fire Protection Association Life Safety Code [NFPA 101] and International Building Codes. The initial FITO assessment of the design changes, required to make TS4550 compliant with current safety and building standards, identified a significant cost increase and schedule impact. An effort was launched to thoroughly evaluate the applicable life safety requirements, examine the context in which they were derived, and determine a means by which the TS4550 modifications could be made within budget and on schedule, while still providing the occupants with appropriate levels of safety.

  1. 42 CFR 482.41 - Condition of participation: Physical environment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...: Life safety from fire. (1) Except as otherwise provided in this section— (i) The hospital must meet the applicable provisions of the 2000 edition of the Life Safety Code of the National Fire Protection Association... Life Safety Code, issued January 14, 2000, for incorporation by reference in accordance with 5 U.S.C...

  2. 42 CFR 482.41 - Condition of participation: Physical environment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...: Life safety from fire. (1) Except as otherwise provided in this section— (i) The hospital must meet the applicable provisions of the 2000 edition of the Life Safety Code of the National Fire Protection Association... Life Safety Code, issued January 14, 2000, for incorporation by reference in accordance with 5 U.S.C...

  3. Efforts to update firefighter safety zone guidelines

    Treesearch

    Bret Butler

    2009-01-01

    One of the most critical decisions made on wildland fires is the identification of suitable safety zones for firefighters during daily fire management operations. To be effective (timely, repeatable, and accurate), these decisions rely on good training and judgment, but also on clear, concise guidelines. This article is a summary of safety zone guidelines and the...

  4. 20 CFR 654.417 - Fire, safety, and first aid.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Fire, safety, and first aid. 654.417 Section..., safety, and first aid. (a) All buildings in which people sleep or eat shall be constructed and maintained...-type water extinguisher. (g) First aid facilities shall be provided and readily accessible for use at...

  5. Maintenance Facilities for Ammunition, Explosives, and Toxics. Design Manual 28.3.

    DTIC Science & Technology

    1981-11-01

    LOADING DOCK RAMP PROTECTION 28.3-2 8. FIRE PROTECTION 28.3-2 9. SECURITY 28.3-2 10. SAFETY 28.3-2 Section 2. GENERAL AMMUNITION MAINTENANCE SHOPS 28.3...protection in accordance with Section 3 1910.23c, Occupatioual Safety and Health Act Standards Manual. 5 8. FIRE PROTECTION. Fire protection for all...Volume 1, and Fire Protection Engineering, NAVFAC DM-8. 9. SECURITY. Maintenance facilities for ammunition, explosives, and I toxics shall be located so

  6. Optimization of Skill Retention in the U. S. Army through Initial Training Analysis and Design: Skill Sustainment Exercises. Volume 3.

    DTIC Science & Technology

    1983-05-01

    Firing data cards. PROCEDURES I. Prior to live fire exercises all firers must be oriented on range procedures. 2. Preparatory marksmanship training...Ordnance detail. 2. Range safety officer. 7. Medical personnel. 3. Firing line safety NCOs. 8. Control tower operators. i 4. Scorer (I per firer ). 9. Pit...phones and wire (for PIT commo). PROCEDURES I. Prior to live fire exercises, all firers must be oriented on range procedures. 2. Scorers are responsible

  7. 24 CFR 201.20 - Property improvement loan eligibility.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... preservation of historic structures. (2) Where the proceeds are to be used for a fire safety equipment loan... jurisdiction over the fire safety requirements of health care facilities prior to making application for a loan...

  8. 24 CFR 201.20 - Property improvement loan eligibility.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... preservation of historic structures. (2) Where the proceeds are to be used for a fire safety equipment loan... jurisdiction over the fire safety requirements of health care facilities prior to making application for a loan...

  9. 24 CFR 201.20 - Property improvement loan eligibility.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... preservation of historic structures. (2) Where the proceeds are to be used for a fire safety equipment loan... jurisdiction over the fire safety requirements of health care facilities prior to making application for a loan...

  10. 24 CFR 232.540 - Method of loan payment and amortization period.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Purchase and Installation of Fire Safety Equipment Eligible Security Instruments § 232.540 Method of loan... either 60, 120, or 180 monthly amortization payments. No fire safety loan shall have an amortization...

  11. 24 CFR 232.540 - Method of loan payment and amortization period.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Purchase and Installation of Fire Safety Equipment Eligible Security Instruments § 232.540 Method of loan... either 60, 120, or 180 monthly amortization payments. No fire safety loan shall have an amortization...

  12. 24 CFR 232.540 - Method of loan payment and amortization period.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Purchase and Installation of Fire Safety Equipment Eligible Security Instruments § 232.540 Method of loan... either 60, 120, or 180 monthly amortization payments. No fire safety loan shall have an amortization...

  13. 24 CFR 201.20 - Property improvement loan eligibility.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... preservation of historic structures. (2) Where the proceeds are to be used for a fire safety equipment loan... jurisdiction over the fire safety requirements of health care facilities prior to making application for a loan...

  14. Report of the oversight assessment of the operational readiness review of the Savannah River Site Defense Waste Processing Facility Cold Chemical Runs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, B.

    1993-03-01

    This report presents the results of an oversight assessment (OA) conducted by the US Department of Energy's (DOE) Office of Environment, Safety and Health (EH) of the operational readiness review (ORR) activities for the Cold Chemical Runs (CCRs) at the Defense Waste Processing Facility (DWPF) located at Savannah River Site (SRS). The EH OA of this facility took place concurrently with an ORR performed by the DOE Office of Environmental Restoration and Waste Management (EM). The EM ORR was conducted from September 28, 1992, through October 9, 1992, although portions of the EM ORR were extended beyond this period. Themore » EH OA evaluated the comprehensiveness and effectiveness of the EM ORR. The EH OA was designed to ascertain whether the EM ORR was thorough and demonstrated sufficient inquisitiveness to verify that the implementation of programs and procedures is adequate to assure the protection of worker safety and health. The EH OA was carried out in accordance with the protocol and procedures of the EH Program for Oversight Assessment of Operational Readiness Evaluations for Startups and Restarts,'' dated September 15, 1992. Based on its OA and verification of the resolution of EH OA findings, the EH OA Team believes that the startup of the CCRs may be safely begun, pending satisfactory completion and verification of the prestart findings identified by the EM ORR. The EH OA was based primarily on an evaluation of the comprehensiveness and effectiveness of the EM ORR and addressed the following areas: industrial safety, industrial hygiene, and respiratory protection; fire protection; and chemical safety. The EH OA conducted independent vertical-slice'' reviews to confirm EM ORR results in the areas of confined-space entry, respiratory protection, fire protection, and chemical safety.« less

  15. Can Fire and Rescue Services and the National Health Service work together to improve the safety and wellbeing of vulnerable older people? Design of a proof of concept study

    PubMed Central

    2010-01-01

    Background Older adults are at increased risk both of falling and of experiencing accidental domestic fire. In addition to advanced age, these adverse events share the risk factors of balance or mobility problems, cognitive impairment and socioeconomic deprivation. For both events, the consequences include significant injury and death, and considerable socioeconomic costs for the individual and informal carers, as well as for emergency services, health and social care agencies. Secondary prevention services for older people who have fallen or who are identifiable as being at high risk of falling include NHS Falls clinics, where a multidisciplinary team offers an individualised multifactorial targeted intervention including strength and balance exercise programmes, medication changes and home hazard modification. A similar preventative approach is employed by most Fire and Rescue Services who conduct Home Fire Safety Visits to assess and, if necessary, remedy domestic fire risk, fit free smoke alarms with instruction for use and maintenance, and plan an escape route. We propose that the similarity of population at risk, location, specific risk factors and the commonality of preventative approaches employed could offer net gains in terms of feasibility, effectiveness and acceptability if activities within these two preventative approaches were to be combined. Methods/Design This prospective proof of concept study, currently being conducted in two London boroughs, (Southwark and Lambeth) aims to reduce the incidence of both fires and falls in community-dwelling older adults. It comprises two concurrent 12-month interventions: the integration of 1) fall risk assessments into the Brigade's Home Fire Safety Visit and 2) fire risk assessments into Falls services by inviting older clinic attendees to book a Visit. Our primary objective is to examine the feasibility and effectiveness of these interventions. Furthermore, we are evaluating their acceptability and value to key stakeholders and services users. Discussion If our approach proves feasible and the risk assessment is both effective and acceptable, we envisage advocating a partnership model of working more broadly to fire and rescue services and health services in Britain, such that effective integration of preventative services for older people becomes routine for an ageing population. PMID:21129185

  16. Major Losses

    ERIC Educational Resources Information Center

    Kravis, Miles

    2009-01-01

    From 2003 to 2005, fires on school properties cost about $85 million a year. An estimated 14,700 fires required a fire department response: 36 percent were trash fires, 19 percent were fires in open fields, and 43 percent were structural fires. Sometimes, the needs of school security seem to conflict with the requirements of fire safety. In this…

  17. Foam composite structures. [for fire retardant airframe materials

    NASA Technical Reports Server (NTRS)

    Delano, C. B.; Milligan, R. J.

    1976-01-01

    The need to include fire resistant foams into state of the art aircraft interior paneling to increase passenger safety in aircraft fires was studied. Present efforts were directed toward mechanical and fire testing of panels with foam inclusions. Skinned foam filled honeycomb and PBI structural foams were the two constructions investigated with attention being directed toward weight/performance/cost trade-off. All of the new panels demonstrated improved performance in fire and some were lighter weight but not as strong as the presently used paneling. Continued efforts should result in improved paneling for passenger safety. In particular the simple partial filling (fire side) of state-of-the-art honeycomb with fire resistant foams with little sacrifice in weight would result in panels with increased fire resistance. More important may be the retarded rate of toxic gas evolution in the fire due to the protection of the honeycomb by the foam.

  18. Cockpit emergency safety system

    NASA Astrophysics Data System (ADS)

    Keller, Leo

    2000-06-01

    A comprehensive safety concept is proposed for aircraft's experiencing an incident to the development of fire and smoke in the cockpit. Fire or excessive heat development caused by malfunctioning electrical appliance may produce toxic smoke, may reduce the clear vision to the instrument panel and may cause health-critical respiration conditions. Immediate reaction of the crew, safe respiration conditions and a clear undisturbed view to critical flight information data can be assumed to be the prerequisites for a safe emergency landing. The personal safety equipment of the aircraft has to be effective in supporting the crew to divert the aircraft to an alternate airport in the shortest possible amount of time. Many other elements in the cause-and-effect context of the emergence of fire, such as fire prevention, fire detection, the fire extinguishing concept, systematic redundancy, the wiring concept, the design of the power supplying system and concise emergency checklist procedures are briefly reviewed, because only a comprehensive and complete approach will avoid fatal accidents of complex aircraft in the future.

  19. Consequences of Fire: The Killing Fumes

    MedlinePlus

    ... Electric Vehicles Fire Fighter Safety and Response for Solar Power Systems Fire Fighting Tactics Under Wind Driven ... Protection Devices Development of Fire Mitigations Solutions for PV Systems Installed on Building Roofs - Phase 1 Electric/ ...

  20. Research on ignition and flame spread of solid materials in Japan

    NASA Technical Reports Server (NTRS)

    Ito, Kenichi; Fujita, Osamu

    1995-01-01

    Fire safety is one of the main concerns for crewed missions such as the space station. Materials used in spacecraft may burn even if metalic. There are severe restrictions on the materials used in spacecraft from the view of fire safety. However, such restrictions or safety standards are usually determined based on experimental results under normal gravity, despite large differences between the phenomena under normal and microgravity. To evaluate the appropriateness of materials for use in space, large amount of microgravity fire-safety combustion data is urgently needed. Solid material combustion under microgravity, such as ignition and flame spread, is a relatively new research field in Japan. As the other reports in this workshop describe, most of microgravity combustion research in Japan is droplet combustion as well as some research on gas phase combustion. Since JAMIC, the Japan Microgravity Center, (which offers 10 seconds microgravity time) opened in 1992, microgravity combustion research is robust, and many drop tests relating to solid combustion (paper combustion, cotton string combustion, metal combustion with Aluminium or Magnesium) have been performed. These tests proved that the 10 seconds of microgravity time at JAMIC is useful for solid combustion research. Some experiments were performed before JAMIC opened. For example, latticed paper was burned under microgravity by using a 50 m drop tower to simulate porous material combustion under microgravity. A 50 m tower provides only 2 seconds microgravity time however, and it was not long enough to investigate the solid combustion phenomena.

Top