46 CFR 108.633 - Fire stations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Fire stations. 108.633 Section 108.633 Shipping COAST... Equipment Markings and Instructions § 108.633 Fire stations. Each fire station must be identified by marking: “FIRE STATION NO. __;” next to the station in letters and numbers at least 5 centimeters (2 inches) high. ...
46 CFR 108.633 - Fire stations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Equipment Markings and Instructions § 108.633 Fire stations. Each fire station must be identified by marking: “FIRE STATION NO. __;” next to the station in letters and numbers at least 5 centimeters (2 inches) high. ... 46 Shipping 4 2013-10-01 2013-10-01 false Fire stations. 108.633 Section 108.633 Shipping COAST...
46 CFR 108.633 - Fire stations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Equipment Markings and Instructions § 108.633 Fire stations. Each fire station must be identified by marking: “FIRE STATION NO. __;” next to the station in letters and numbers at least 5 centimeters (2 inches) high. ... 46 Shipping 4 2014-10-01 2014-10-01 false Fire stations. 108.633 Section 108.633 Shipping COAST...
46 CFR 108.633 - Fire stations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Equipment Markings and Instructions § 108.633 Fire stations. Each fire station must be identified by marking: “FIRE STATION NO. __;” next to the station in letters and numbers at least 5 centimeters (2 inches) high. ... 46 Shipping 4 2011-10-01 2011-10-01 false Fire stations. 108.633 Section 108.633 Shipping COAST...
46 CFR 108.633 - Fire stations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Equipment Markings and Instructions § 108.633 Fire stations. Each fire station must be identified by marking: “FIRE STATION NO. __;” next to the station in letters and numbers at least 5 centimeters (2 inches) high. ... 46 Shipping 4 2012-10-01 2012-10-01 false Fire stations. 108.633 Section 108.633 Shipping COAST...
Space station internal environmental and safety concerns
NASA Technical Reports Server (NTRS)
Cole, Matthew B.
1987-01-01
Space station environmental and safety concerns, especially those involving fires, are discussed. Several types of space station modules and the particular hazards associated with each are briefly surveyed. A brief history of fire detection and suppression aboard spacecraft is given. Microgravity fire behavior, spacecraft fire detector systems, space station fire suppression equipment and procedures, and fire safety in hyperbaric chambers are discussed.
A portable station for recording fire weather data
John R. Murray; Clive M. Countryman
1968-01-01
A portable station for recording fire weather data has been developed for use in wildland fires, prescribed burns, evaluating sites for fire weather stations, and fire research. Housed in a mechanic's tool box, the station weighs about 60 pounds. One man can have it ready to operate in about 15 minutes. The unit can record five weather variables, but additional...
46 CFR 132.130 - Fire stations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Fire stations. 132.130 Section 132.130 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS FIRE-PROTECTION EQUIPMENT Fire Main § 132.130 Fire stations. (a) Except as provided by paragraph (b) of this section, ire...
Firefighters from Mayport Naval Station train at CCAFS
NASA Technical Reports Server (NTRS)
2000-01-01
A Mobile Aircraft Fire Trainer vehicle from Naval Station Mayport, Fla., stands by during fire training exercises at Cape Canaveral Air Force Station Pad 30. In the background is the simulated aircraft that was set on fire for the exercise. Firefighters with the Fire and Emergency Services at the Naval Station (in the background) gather around the site of the extinguished flames.
An aid to streamlining fire-weather station networks
R. William Furman
1975-01-01
For reasons of economy it may be necessary to close one or several fire-weather stations in a protection area. Since it is logical to close those stations that will have the least impact on the ability of the fire manager to assess overall fire danger, it is desirable to know if there is duplication in monitoring fire climate, and to what degree. A method is proposed...
Firefighters from Mayport Naval Station train at CCAFS
NASA Technical Reports Server (NTRS)
2000-01-01
Firefighters in full gear douse a fire on a simulated aircraft. The firefighters, who are with Fire and Emergency Services at the Naval Station Mayport, Fla., are taking part in fire training exercises at Cape Canaveral Air Force Station Pad 30.
73. BUILDING NO. 3316, PICATINNY ARSENAL FIRE STATION, LOOKING NORTH ...
73. BUILDING NO. 3316, PICATINNY ARSENAL FIRE STATION, LOOKING NORTH AT NORTHWEST AND SOUTHWEST SIDES OF 1903 FIRE STATION. BUILDING NO. 3315, AUTO SHOP, IS VISIBLE IN BACKGROUND. - Picatinny Arsenal, State Route 15 near I-80, Dover, Morris County, NJ
FIRE STATION AND GUARD HOUSE, ELEVATIONS, SECTIONS, AND DETAILS. Plan ...
FIRE STATION AND GUARD HOUSE, ELEVATIONS, SECTIONS, AND DETAILS. Plan No. 6754-320, dated August 1, 1933. Constructing Division, Office of the Constructing Quartermaster - Hamilton Field, Fire Station & Guard House, Southwest corner of Seventh Street & Hangar Avenue, Novato, Marin County, CA
FIRE STATION AND GUARD HOUSE, PLANS AND DETAILS. Plan No. ...
FIRE STATION AND GUARD HOUSE, PLANS AND DETAILS. Plan No. 6754-319, dated August 1, 1933. Construction Division, Office of the Constructing Quartermaster - Hamilton Field, Fire Station & Guard House, Southwest corner of Seventh Street & Hangar Avenue, Novato, Marin County, CA
2000-09-14
KENNEDY SPACE CENTER, FLA. -- A Mobile Aircraft Fire Trainer vehicle from Naval Station Mayport, Fla., stands by during fire training exercises at Cape Canaveral Air Force Station Pad 30. In the background is the simulated aircraft that was set on fire for the exercise. Firefighters with the Fire and Emergency Services at the Naval Station (in the background) gather around the site of the extinguished flames.
2000-09-14
KENNEDY SPACE CENTER, FLA. -- A Mobile Aircraft Fire Trainer vehicle from Naval Station Mayport, Fla., stands by during fire training exercises at Cape Canaveral Air Force Station Pad 30. In the background is the simulated aircraft that was set on fire for the exercise. Firefighters with the Fire and Emergency Services at the Naval Station (in the background) gather around the site of the extinguished flames.
33 CFR 165.152 - Coast Guard Station Fire Island, Long Island, New York-safety zone.
Code of Federal Regulations, 2011 CFR
2011-07-01
... § 165.152 Coast Guard Station Fire Island, Long Island, New York—safety zone. (a) Location. The following waters of Fire Island Inlet are a safety zone: Beginning at a point on shore at 40°37.523′ N, 073... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Coast Guard Station Fire Island...
Burton, Carmen; Hoefen, Todd M.; Plumlee, Geoffrey S.; Baumberger, Katherine L.; Backlin, Adam R.; Gallegos, Elizabeth; Fisher, Robert N.
2016-01-01
Most research on the effects of wildfires on stream water quality has focused on suspended sediment and nutrients in streams and water bodies, and relatively little research has examined the effects of wildfires on trace elements. The purpose of this study was two-fold: 1) to determine the effect of the 2009 Station Fire in the Angeles National Forest northeast of Los Angeles, CA on trace element concentrations in streams, and 2) compare trace elements in post-fire stormflow water quality to criteria for aquatic life to determine if trace elements reached concentrations that can harm aquatic life. Pre-storm and stormflow water-quality samples were collected in streams located inside and outside of the burn area of the Station Fire. Ash and burned soil samples were collected from several locations within the perimeter of the Station Fire. Filtered concentrations of Fe, Mn, and Hg and total concentrations of most trace elements in storm samples were elevated as a result of the Station Fire. In contrast, filtered concentrations of Cu, Pb, Ni, and Se and total concentrations of Cu were elevated primarily due to storms and not the Station Fire. Total concentrations of Se and Zn were elevated as a result of both storms and the Station Fire. Suspended sediment in stormflows following the Station Fire was an important transport mechanism for trace elements. Cu, Pb, and Zn primarily originate from ash in the suspended sediment. Fe primarily originates from burned soil in the suspended sediment. As, Mn, and Ni originate from both ash and burned soil. Filtered concentrations of trace elements in stormwater samples affected by the Station Fire did not reach levels that were greater than criteria established for aquatic life. Total concentrations for Fe, Pb, Ni, and Zn were detected at concentrations above criteria established for aquatic life.
Burton, Carmen A.; Hoefen, Todd M.; Plumlee, Geoffrey S.; Baumberger, Katherine L.; Backlin, Adam R.; Gallegos, Elizabeth; Fisher, Robert N.
2016-01-01
Most research on the effects of wildfires on stream water quality has focused on suspended sediment and nutrients in streams and water bodies, and relatively little research has examined the effects of wildfires on trace elements. The purpose of this study was two-fold: 1) to determine the effect of the 2009 Station Fire in the Angeles National Forest northeast of Los Angeles, CA on trace element concentrations in streams, and 2) compare trace elements in post-fire stormflow water quality to criteria for aquatic life to determine if trace elements reached concentrations that can harm aquatic life. Pre-storm and stormflow water-quality samples were collected in streams located inside and outside of the burn area of the Station Fire. Ash and burned soil samples were collected from several locations within the perimeter of the Station Fire. Filtered concentrations of Fe, Mn, and Hg and total concentrations of most trace elements in storm samples were elevated as a result of the Station Fire. In contrast, filtered concentrations of Cu, Pb, Ni, and Se and total concentrations of Cu were elevated primarily due to storms and not the Station Fire. Total concentrations of Se and Zn were elevated as a result of both storms and the Station Fire. Suspended sediment in stormflows following the Station Fire was an important transport mechanism for trace elements. Cu, Pb, and Zn primarily originate from ash in the suspended sediment. Fe primarily originates from burned soil in the suspended sediment. As, Mn, and Ni originate from both ash and burned soil. Filtered concentrations of trace elements in stormwater samples affected by the Station Fire did not reach levels that were greater than criteria established for aquatic life. Total concentrations for Fe, Pb, Ni, and Zn were detected at concentrations above criteria established for aquatic life. PMID:27144270
NASA Astrophysics Data System (ADS)
Tajedi, Noor Aqilah A.; Sukor, Nur Sabahiah A.; Ismail, Mohd Ashraf M.; Shamsudin, Shahrul A.
2017-10-01
The purpose of this paper is to compare the fire evacuation plan and preparation at the underground train stations in the different countries. The methodology for this study was using the extended questionnaire survey to investigate the Rapid Rail Sdn Bhd, Malaysia's fire safety plan and preparation at the underground train stations. There were four sections in the questionnaire which included (i) background of the respondents, (ii) the details on the train stations, safety instruction and fire evacuation exercises (iii) technical systems, installation and equipment at the underground stations and (iv) procedures and technical changes related to fire safety that had been applied by the operators. Previously, the respondents from the different train operator services in the developed countries had completed the questionnaires. This paper extends the response from the Rapid Rail Sdn Bhd to compare the emergency procedures and preparation for fire event with the developed countries. As a result, this study found that the equipment and facilities that provided at the underground train stations that operated by Rapid Rail are relevant for fire safety procedures and needs. The main advantage for Rapid Rail is the underground stations were designed with two or more entrances/exits that may perform better evacuation compare to one main entrance/exit train stations in the other developed countries.
Assistance to Firefighters Program: Distribution of Fire Grant Funding
2010-07-13
shows the appropriations history for firefighter assistance, including AFG, SAFER, and the Fire Station Construction Grants ( SCG ) provided in the...1.109 billion $210 million $6.521 billion a. Assistance to Firefighters Fire Station Construction Grants ( SCG ) grants were funded by the American...and FY2010. The application period for ARRA Assistance to Firefighters Fire Station Construction Grants ( SCG ) opened on June 11 and closed on July 10
46 CFR 132.130 - Fire stations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... discharge both solid stream and water spray. (h) Each pipe and fire hydrant must be placed so that the fire... or other suitable corrosion-resistant material and comply with NFPA 1963. (k) Each fire hydrant must... 46 Shipping 4 2011-10-01 2011-10-01 false Fire stations. 132.130 Section 132.130 Shipping COAST...
Sparer, Emily H; Prendergast, Daniel P; Apell, Jennifer N; Bartzak, Madeleine R; Wagner, Gregory R; Adamkiewicz, Gary; Hart, Jaime E; Sorensen, Glorian
2017-10-01
Firefighters are at an increased risk for many types of cancer. Although most studies on this topic focus on exposures encountered while fighting fires, exposures at the fire station are also cause for concern. This pilot study aimed to describe air quality within a few fire stations in and around Boston, Massachusetts, and to investigate physical and organizational factors that may influence levels of contaminants in stations. Air sampling of particulate matter less than 2.5 μm in diameter (PM2.5) and particle-bound polycyclic aromatic hydrocarbons (PAHs) was completed at four fire stations in Spring, 2016. Sampling occurred in the kitchen, truck bay, and just outside the station. Data were analyzed to assess differences between and within stations. Interviews (n =7) were conducted with officers at each station to explore health and safety-related organizational policies and practices. Interviews were transcribed and analyzed for thematic content. At each station, levels of contaminants were higher in the truck bays than either the outdoors or kitchen, and varied the most throughout the day. The station with the highest exposures in the truck bay had the lowest levels in the kitchen, which was possibly explained by new building materials and effective separation between building zones. The age and layout of the stations appeared to determine the extent to which policies favoring exhaust capture were implemented. Levels of PM2.5 and PAH inside fire stations may contribute to firefighter cancer risk. Through understanding contaminant variability, we can begin to design and test interventions that improve cancer prevention.
NASA Technical Reports Server (NTRS)
Youngblood, Wallace W.
1990-01-01
Viewgraphs of increased fire and toxic contaminant detection responsivity by use of distributed, aspirating sensors for space station are presented. Objectives of the concept described are (1) to enhance fire and toxic contaminant detection responsivity in habitable regions of space station; (2) to reduce system weight and complexity through centralized detector/monitor systems; (3) to increase fire signature information from selected locations in a space station module; and (4) to reduce false alarms.
33 CFR 165.152 - Coast Guard Station Fire Island, Long Island, New York-safety zone.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Coast Guard Station Fire Island, Long Island, New York-safety zone. 165.152 Section 165.152 Navigation and Navigable Waters COAST GUARD... § 165.152 Coast Guard Station Fire Island, Long Island, New York—safety zone. (a) Location. The...
77 FR 42228 - Proposed Amendment of Class E Airspace; Wilkes-Barre, PA
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-18
... airport. This action would also recognize the name change of Hanover Township Fire Station 5 Heliport... Hanover Township Fire Station 5 Heliport. Class E airspace designations are published in Paragraph 6005 of...]24'00'' N., long. 75[deg]39'39'' W.) Hanover Township Fire Station 5 Heliport (Lat. 41[deg]14'08'' N...
Test of wind predictions for peak fire-danger stations in Oregon and Washington.
Owen P. Cramer
1957-01-01
Relative accuracy of several wind-speed forecasting methods was tested during the forest fire seasons of 1950 and 1951. For the study, three fire-weather forecast centers of the U. S. Weather Bureau prepared individual station forecasts for 11 peak stations within the national. forests of Oregon and Washington. These spot forecasts were considered...
49 CFR 192.171 - Compressor stations: Additional safety equipment.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 3 2011-10-01 2011-10-01 false Compressor stations: Additional safety equipment... Pipeline Components § 192.171 Compressor stations: Additional safety equipment. (a) Each compressor station must have adequate fire protection facilities. If fire pumps are a part of these facilities, their...
Firefighters from Mayport Naval Station train at CCAFS
NASA Technical Reports Server (NTRS)
2000-01-01
During training exercises at Cape Canaveral Air Force Station Pad 30, firefighters with the Fire and Emergency Services at the Naval Station Mayport, Fla., turn their hoses toward the fire on the simulated aircraft.
Rocky Mountain Research Station 2008-2012 National Fire Plan Investments
Erika Gallegos
2013-01-01
This report highlights selected accomplishments by the USDA Forest Service Rocky Mountain Research Station's Wildland Fire and Fuels Research & Development projects in support of the National Fire Plan from 2008 through 2012. These projects are examples of the broad range of knowledge and tools developed by National Fire Plan funding beginning in 2008.
Fire danger rating network density
Rudy M. King; R. William Furman
1976-01-01
Conventional statistical techniques are used to answer the question, "What is the necessary station density for a fire danger network?" The Burning Index of the National Fire-Danger Rating System is used as an indicator of fire danger. Results are presented as station spacing in tabular form for each of six regions in the western United States.
2000-09-14
KENNEDY SPACE CENTER, FLA. -- Firefighters in full gear douse a fire on a simulated aircraft. The firefighters, who are with Fire and Emergency Services at the Naval Station Mayport, Fla., are taking part in fire training exercises at Cape Canaveral Air Force Station Pad 30.
2000-09-14
KENNEDY SPACE CENTER, FLA. -- Firefighters in full gear douse a fire on a simulated aircraft. The firefighters, who are with Fire and Emergency Services at the Naval Station Mayport, Fla., are taking part in fire training exercises at Cape Canaveral Air Force Station Pad 30.
Glare-reducing goggles for lookouts.
Richard E. McArdle; William G. Morris; Thornton T. Munger
1936-01-01
Detection of forest fires while they are still small is so important in forest protection that studies of the visibility of forest fire smokes from lookout points has been one of the principal phases of the fire studies program of the Pacific Northwest Forest Experiment Station. One phase of fire detection is the personal efficiency of the lookout. The Station has...
Computer evaluation of existing and proposed fire lookouts
Romain M. Mees
1976-01-01
A computer simulation model has been developed for evaluating the fire detection capabilities of existing and proposed lookout stations. The model uses coordinate location of fires and lookouts, tower elevation, and topographic data to judge location of stations, and to determine where a fire can be seen. The model was tested by comparing it with manual detection on a...
46 CFR 76.10-10 - Fire station hydrants, hose and nozzles.
Code of Federal Regulations, 2014 CFR
2014-10-01
...) Use National Standard fire hose coupling threads for the 11/2 inch (38 millimeter) and 21/2 inch (64... 46 Shipping 3 2014-10-01 2014-10-01 false Fire station hydrants, hose and nozzles. 76.10-10 Section 76.10-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE...
Firefighters from Mayport Naval Station train at CCAFS
NASA Technical Reports Server (NTRS)
2000-01-01
A training officer controls elements of a fire training exercise at Cape Canaveral Air Force Station Pad 30 for firefighters with Fire and Emergency Services at the Naval Station Mayport, Fla. The firefighters tackled flames from a burning simulated aircraft.
Meteorological factors in the Quartz Creek forest fire
H. T. Gisborne
1927-01-01
It is not often that a large forest fire occurs conveniently near a weather station specially equipped for measuring forest-fire weather. The 13,000-acre Quartz Creek fire on the Kaniksu National Forest during the summer of 1936 was close enough to the Priest River Experimental Forest of the Northern Rocky Mountain Forest Experiment Station for the roar of the flumes...
46 CFR 76.10-10 - Fire station hydrants, hose and nozzles-T/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) Use National Standard fire hose coupling threads for the 11/2 inch (38 millimeter) and 21/2 inch (64... 46 Shipping 3 2010-10-01 2010-10-01 false Fire station hydrants, hose and nozzles-T/ALL. 76.10-10 Section 76.10-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE...
46 CFR 76.10-10 - Fire station hydrants, hose and nozzles-T/ALL.
Code of Federal Regulations, 2011 CFR
2011-10-01
...) Use National Standard fire hose coupling threads for the 11/2 inch (38 millimeter) and 21/2 inch (64... 46 Shipping 3 2011-10-01 2011-10-01 false Fire station hydrants, hose and nozzles-T/ALL. 76.10-10 Section 76.10-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE...
46 CFR 76.10-10 - Fire station hydrants, hose and nozzles-T/ALL.
Code of Federal Regulations, 2012 CFR
2012-10-01
...) Use National Standard fire hose coupling threads for the 11/2 inch (38 millimeter) and 21/2 inch (64... 46 Shipping 3 2012-10-01 2012-10-01 false Fire station hydrants, hose and nozzles-T/ALL. 76.10-10 Section 76.10-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE...
46 CFR 76.10-10 - Fire station hydrants, hose and nozzles-T/ALL.
Code of Federal Regulations, 2013 CFR
2013-10-01
...) Use National Standard fire hose coupling threads for the 11/2 inch (38 millimeter) and 21/2 inch (64... 46 Shipping 3 2013-10-01 2013-10-01 false Fire station hydrants, hose and nozzles-T/ALL. 76.10-10 Section 76.10-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE...
Experiments to ensure Space Station fire safety - A challenge
NASA Technical Reports Server (NTRS)
Youngblood, W. W.; Seiser, K. M.
1988-01-01
Three experiments have been formulated in order to address prominent fire safety requirements aboard the NASA Space Shuttle; these experiments are to be conducted as part of a Space Station-based Technology Development Mission for the growth phase of Space Station construction and operation. The experiments are: (1) an investigation of the flame-spread rate and combustion-product evolution in the burning of typical spacecraft materials in low gravity; (2) an evaluation of the interaction of fires and candidate fire extinguishers in low gravity; and (3) an investigation of the persistence and propagation of smoldering and deep-seated combustion in low gravity.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River... Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River, Maryland, danger zones. (a) Aerial firing range—(1) The danger zone. The waters...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River... Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River, Maryland, danger zones. (a) Aerial firing range—(1) The danger zone. The waters...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River... Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River, Maryland, danger zones. (a) Aerial firing range—(1) The danger zone. The waters...
Deborah J. Chavez; James D. Absher; Patricia L. Winter
2008-01-01
Fire events often have a large impact on recreation and tourism, yet these issues had not been addressed from a social science perspective. To address his, the Wildland Recreation and Urban Cultures Research Work Unit (RWU) of the Pacific Southwest Research Station acquired funding through the National Fire Plan within the community assistance topic area. The three...
Combustion and fires in low gravity
NASA Technical Reports Server (NTRS)
Friedman, Robert
1994-01-01
Fire safety always receives priority attention in NASA mission designs and operations, with emphasis on fire prevention and material acceptance standards. Recently, interest in spacecraft fire-safety research and development has increased because improved understanding of the significant differences between low-gravity and normal-gravity combustion suggests that present fire-safety techniques may be inadequate or, at best, non-optimal; and the complex and permanent orbital operations in Space Station Freedom demand a higher level of safety standards and practices. This presentation outlines current practices and problems in fire prevention and detection for spacecraft, specifically the Space Station Freedom's fire protection. Also addressed are current practices and problems in fire extinguishment for spacecraft.
NASA Astrophysics Data System (ADS)
Hoskins, Aaron B.
Forest fires cause a significant amount of damage and destruction each year. Optimally dispatching resources reduces the amount of damage a forest fire can cause. Models predict the fire spread to provide the data required to optimally dispatch resources. However, the models are only as accurate as the data used to build them. Satellites are one valuable tool in the collection of data for the forest fire models. Satellites provide data on the types of vegetation, the wind speed and direction, the soil moisture content, etc. The current operating paradigm is to passively collect data when possible. However, images from directly overhead provide better resolution and are easier to process. Maneuvering a constellation of satellites to fly directly over the forest fire provides higher quality data than is achieved with the current operating paradigm. Before launch, the location of the forest fire is unknown. Therefore, it is impossible to optimize the initial orbits for the satellites. Instead, the expected cost of maneuvering to observe the forest fire determines the optimal initial orbits. A two-stage stochastic programming approach is well suited for this class of problem where initial decisions are made with an uncertain future and then subsequent decisions are made once a scenario is realized. A repeat ground track orbit provides a non-maneuvering, natural solution providing a daily flyover of the forest fire. However, additional maneuvers provide a second daily flyover of the forest fire. The additional maneuvering comes at a significant cost in terms of additional fuel, but provides more data collection opportunities. After data are collected, ground stations receive the data for processing. Optimally selecting the ground station locations reduce the number of built ground stations and reduces the data fusion issues. However, the location of the forest fire alters the optimal ground station sites. A two-stage stochastic programming approach optimizes the selection of ground stations to maximize the expected amount of data downloaded from a satellite. The approaches of selecting initial orbits and ground station locations including uncertainty will provide a robust system to reduce the amount of damage caused by forest fires.
Risks and issues in fire safety on the Space Station
NASA Technical Reports Server (NTRS)
Friedman, Robert
1993-01-01
A fire in the inhabited portion of a spacecraft is a greatly feared hazard, but fire protection in space operations is complicated by two factors. First, the spacecraft cabin is an enclosed volume, which limits the resources for fire fighting and the options for crew escape. Second, an orbiting spacecraft experiences a balance of forces, creating a near-zero-gravity (microgravity) environment that profoundly affects the characteristics of fire initiation, spread, and suppression. The current Shuttle Orbiter is protected by a fire-detection and suppression system whose requirements are derived of necessity from accepted terrestrial and aircraft standards. While experience has shown that Shuttle fire safety is adequate, designers recognize that improved systems to respond specifically to microgravity fire characteristics are highly desirable. Innovative technology is particularly advisable for the Space Station, a forthcoming space community with a complex configuration and long-duration orbital missions, in which the effectiveness of current fire-protection systems is unpredictable. The development of risk assessments to evaluate the probabilities and consequences of fire incidents in spacecraft are briefly reviewed. It further discusses the important unresolved issues and needs for improved fire safety in the Space Station, including those of material selection, spacecraft atmospheres, fire detection, fire suppression, and post-fire restoration.
Pedestrian evacuation at the subway station under fire
NASA Astrophysics Data System (ADS)
Xiao-Xia, Yang; Hai-Rong, Dong; Xiu-Ming, Yao; Xu-Bin, Sun
2016-04-01
With the development of urban rail transit, ensuring the safe evacuation of pedestrians at subway stations has become an important issue in the case of an emergency such as a fire. This paper chooses the platform of line 4 at the Beijing Xuanwumen subway station to study the emergency evacuation process under fire. Based on the established platform, effects of the fire dynamics, different initial pedestrian densities, and positions of fire on evacuation are investigated. According to simulation results, it is found that the fire increases the air temperature and the smoke density, and decreases pedestrians’ visibility and walking velocity. Also, there is a critical initial density at the platform if achieving a safe evacuation within the required 6 minutes. Furthermore, different positions of fire set in this paper have little difference on crowd evacuation if the fire is not large enough. The suggestions provided in this paper are helpful for the subway operators to prevent major casualties. Project supported by the National Natural Science Foundation of China (Grant Nos. 61322307 and 61233001).
27. CONTEXT VIEW LOOKING EAST SHOWING BUILDING 227 (FIRE STATION) ...
27. CONTEXT VIEW LOOKING EAST SHOWING BUILDING 227 (FIRE STATION) AT RIGHT AND BUILDING 229 (ELECTRIC POWER STATION) AT LEFT IN ASSEMBLY AREA. - Loring Air Force Base, Weapons Storage Area, Northeastern corner of base at northern end of Maine Road, Limestone, Aroostook County, ME
13. Readville Station (destroyed by fire in June 1983) and ...
13. Readville Station (destroyed by fire in June 1983) and the Franklin Branch Bridge crossing the Northeast Corridor to the right. Readville, Suffolk Co., MA. Sec. 4116, MP 219.41. - Northeast Railroad Corridor, Amtrak Route between RI/MA State Line & South Station, Boston, Suffolk County, MA
Firefighters from Mayport Naval Station train at CCAFS
NASA Technical Reports Server (NTRS)
2000-01-01
Firefighters surround a burning simulated aircraft during training exercises Cape Canaveral Air Force Station Pad 30. Those at left wait their turn as the crew on the right turn their hoses toward the fire. The firefighters are with Fire and Emergency Services at the Naval Station Mayport, Fla.
26 CFR 49.4252-7 - Wire and equipment service.
Code of Federal Regulations, 2013 CFR
2013-04-01
... services, burglar alarm or fire alarm service, and all other similar services (whether or not oral... following are examples of wire and equipment service: (1) Burglar, fire, or other alarm service where the..., or a police or fire station, or a central station, and over which a signal is transmitted in the case...
26 CFR 49.4252-7 - Wire and equipment service.
Code of Federal Regulations, 2012 CFR
2012-04-01
... services, burglar alarm or fire alarm service, and all other similar services (whether or not oral... following are examples of wire and equipment service: (1) Burglar, fire, or other alarm service where the..., or a police or fire station, or a central station, and over which a signal is transmitted in the case...
NASA Technical Reports Server (NTRS)
Margle, Janice M. (Editor)
1987-01-01
Fire detection, fire standards and testing, fire extinguishment, inerting and atmospheres, fire-related medical science, aircraft fire safety, Space Station safety concerns, microgravity combustion, spacecraft material flammability testing, and metal combustion are among the topics considered.
Spacecraft fire-safety experiments for space station: Technology development mission
NASA Technical Reports Server (NTRS)
Youngblood, Wallace W.
1988-01-01
Three concept designs for low-gravity, fire-safety related experiments are presented, as selected for the purpose of addressing key issues of enhancing safety and yet encouraging access to long-duration, manned spacecraft such as the NASA space station. The selected low-gravity experiments are the following: (1) an investigation of the flame-spread rate and combustion-product evolution of the burning of typical thicknesses of spacecraft materials in very low-speed flows; (2) an evaluation of the interaction of fires and candidate extinguishers in various fire scenarios; and (3) an investigation of the persistence and propagation of smoldering and deep-seated combustion. Each experiment is expected to provide fundamental combustion-science data, as well as the fire-safety applications, and each requires the unique long-duration, low-gravity environment of the space station. Two generic test facilities, i.e., the Combustion Tunnel Facility and the Combustion Facility, are proposed for space station accommodation to support the selected experiments. In addition, three near-term, fire-safety related experiments are described along with other related precursor activities.
Firefighters from Mayport Naval Station train at CCAFS
NASA Technical Reports Server (NTRS)
2000-01-01
A firefighter (right) holds a water hose in readiness as others enter a smoke-filled simulated aircraft. The activities are part of fire training exercises at Cape Canaveral Air Force Station Pad 30 for firefighters with Fire and Emergency Services at the Naval Station Mayport, Fla. The firefighters have already extinguished flames from the aircraft.
VIEW OF EMERGENCY RESPONSE VEHICLES PARKED OUTSIDE BUILDING 331, THE ...
VIEW OF EMERGENCY RESPONSE VEHICLES PARKED OUTSIDE BUILDING 331, THE VEHICLE MAINTENANCE GARAGE AND FIRE STATION. THE BUILDING, ORIGINALLY CONSTRUCTED IN 1953, WAS DESIGNED AND UTILIZED AS A WAREHOUSE. ADDITIONS TO THE STRUCTURE, INCLUDING THE FIRE DEPARTMENT STRUCTURE, WERE COMPLETED IN 1967. (4/7/87) - Rocky Flats Plant, Vehicle Maintenance Garage & Fire Station, Golden, Jefferson County, CO
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-22
... gas-fired combined-cycle power station in Warren County, Virginia, extending over the next 9 years... construction of a new natural gas-fired combined-cycle power station in Warren County, Virginia. A conservation... cause take of the Madison Cave isopod. Dominion Virginia Power proposes to construct a natural gas-fired...
Fire safety practices in the Shuttle and the Space Station Freedom
NASA Technical Reports Server (NTRS)
Friedman, Robert
1993-01-01
The Shuttle reinforces its policy of fire-preventive measures with onboard smoke detectors and Halon 1301 fire extinguishers. The forthcoming Space Station Freedom will have expanded fire protection with photoelectric smoke detectors, radiation flame detectors, and both fixed and portable carbon dioxide fire extinguishers. Many design and operational issues remain to be resolved for Freedom. In particular, the fire-suppression designs must consider the problems of gas leakage in toxic concentrations, alternative systems for single-failure redundancy, and commonality with the corresponding systems of the Freedom international partners. While physical and engineering requirements remain the primary driving forces for spacecraft fire-safety technology, there are, nevertheless, needs and opportunities for the application of microgravity combustion knowledge to improve and optimize the fire-protective systems.
26. SOUTH CORNER OF BUILDING 227 (FIRE STATION) IN ASSEMBLY ...
26. SOUTH CORNER OF BUILDING 227 (FIRE STATION) IN ASSEMBLY AREA. - Loring Air Force Base, Weapons Storage Area, Northeastern corner of base at northern end of Maine Road, Limestone, Aroostook County, ME
25. SOUTHEAST FRONT ELEVATION OF BUILDING 227 (FIRE STATION) IN ...
25. SOUTHEAST FRONT ELEVATION OF BUILDING 227 (FIRE STATION) IN ASSEMBLY AREA. - Loring Air Force Base, Weapons Storage Area, Northeastern corner of base at northern end of Maine Road, Limestone, Aroostook County, ME
2000-09-14
KENNEDY SPACE CENTER, FLA. -- During training exercises at Cape Canaveral Air Force Station Pad 30, firefighters with the Fire and Emergency Services at the Naval Station Mayport, Fla., turn their hoses toward the fire on the simulated aircraft.
2000-09-14
KENNEDY SPACE CENTER, FLA. -- During training exercises at Cape Canaveral Air Force Station Pad 30, firefighters with the Fire and Emergency Services at the Naval Station Mayport, Fla., turn their hoses toward the fire on the simulated aircraft.
The Development of Tactical Leadership Exercises for SIMCAT
1987-07-01
Weapon Station (CWS) "* Engage Targets with a Caliber .50 Machinegun "* Fire the M239 or the M250 Grenade Launcher Other Tasks. The following tasks cannot...commander’s weapon station (CWS). - Engage targets with the coaxial machinegun from the commander’s weapon station (CWS). Fire the M239 or the M250 grenade
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-23
... the E by S Pulaski Rd, Chicago, 10000724 Johnson County Johnson County Courthouse, Courthouse Square... Hamilton County Pillsbury Mountain Forest Fire Observation Station, (Fire Observation Stations of New York...
Critical safety assurance factors for manned spacecraft - A fire safety perspective
NASA Technical Reports Server (NTRS)
Rodney, George A.
1990-01-01
Safety assurance factors for manned spacecraft are discussed with a focus on the Space Station Freedom. A hazard scenario is provided to demonstrate a process commonly used by safety engineers and other analysts to identify onboard safety risks. Fire strategies are described, including a review of fire extinguishing agents being considered for the Space Station. Lessons learned about fire safety technology in other areas are also noted. NASA and industry research on fire safety applications is discussed. NASA's approach to ensuring safety for manned spacecraft is addressed in the context of its multidiscipline program.
FLIGHT LINE, LOOKING TOWARD FLIGHT LINE FIRE STATION (BUILDING 2748)CENTER ...
FLIGHT LINE, LOOKING TOWARD FLIGHT LINE FIRE STATION (BUILDING 2748)CENTER AND AIRCRAFT MAINTENANCE DOCKS (BUILDINGS 2741 AND 2766)LEFT. VIEW TO NORTH - Plattsburgh Air Force Base, U.S. Route 9, Plattsburgh, Clinton County, NY
Smoke from Station Fire Blankets Southern California Anaglyph
2009-09-04
NASA Terra satellite took this anaglyph of several pyrocumulus clouds, created by the Station Fire, visible above the smoke plumes rising from the San Gabriel Mountains north of Los Angeles. 3D glasses are necessary to view this image.
2000-09-14
KENNEDY SPACE CENTER, FLA. -- A training officer controls elements of a fire training exercise at Cape Canaveral Air Force Station Pad 30 for firefighters with Fire and Emergency Services at the Naval Station Mayport, Fla. The firefighters tackled flames from a burning simulated aircraft.
2000-09-14
KENNEDY SPACE CENTER, FLA. -- A training officer controls elements of a fire training exercise at Cape Canaveral Air Force Station Pad 30 for firefighters with Fire and Emergency Services at the Naval Station Mayport, Fla. The firefighters tackled flames from a burning simulated aircraft.
Anemometer performance at fire-weather stations.
Donald A. Haines; John S. Frost
1984-01-01
A survey of 142 fire-weather stations in the Northeastern United States showed that, although maintenance was generally satisfactory, calibration or testing of anemometers was virtually nonexistent. We tested these anemometers using portable equipment that we designed and found the deviations from true wind speed.
2012-09-11
CAPE CANAVERAL, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, Fire and Rescue personnel stand at attention as Kennedy Director Robert Cabana, at right, participates in a 9/11 memorial dedication at Fire Station 1. Kennedy Fire and Rescue Services commemorated the 11th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Kennedy center-wide emergency units dispatched by Fire Control engaged in one-minute sirens, the new memorial was dedicated and the Honor Guard performed a flag-folding ceremony. Photo credit: NASA/Dimitri Gerondidakis
2012-09-11
CAPE CANAVERAL, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, Fire and Rescue personnel stand at attention as Kennedy Director Robert Cabana, at right, participates in a 9/11 memorial dedication at Fire Station 1. Kennedy Fire and Rescue Services commemorated the 11th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Kennedy center-wide emergency units dispatched by Fire Control engaged in one-minute sirens, the new memorial was dedicated and the Honor Guard performed a flag-folding ceremony. Photo credit: NASA/Dimitri Gerondidakis
2012-09-11
CAPE CANAVERAL, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, Fire and Rescue personnel stand at attention as Kennedy Director Robert Cabana participates in a 9/11 memorial dedication at Fire Station 1. Kennedy Fire and Rescue Services commemorated the 11th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Kennedy center-wide emergency units dispatched by Fire Control engaged in one-minute sirens, the new memorial was dedicated and the Honor Guard performed a flag-folding ceremony. Photo credit: NASA/Dimitri Gerondidakis
2012-09-11
CAPE CANAVERAL, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, Fire and Rescue personnel stand at attention as Kennedy Director Robert Cabana, at right, participates in a 9/11 memorial dedication at Fire Station 1. Kennedy Fire and Rescue Services commemorated the 11th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Kennedy center-wide emergency units dispatched by Fire Control engaged in one-minute sirens, the new memorial was dedicated and the Honor Guard performed a flag-folding ceremony. Photo credit: NASA/Dimitri Gerondidakis
2013 Annual Report: Fire Modeling Institute
Robin J. Innes; Faith Ann Heinsch; Kristine M. Lee
2014-01-01
The Fire Modeling Institute (FMI) of the U.S. Forest Service, Rocky Mountain Research Station (RMRS), is a national and international resource for fire managers. Located within the Fire, Fuel, and Smoke Science Program at the Missoula Fire Sciences Laboratory (Fire Lab) in Montana, FMI helps managers utilize fire and fuel science and technology developed throughout the...
30 CFR 57.4261 - Shaft-station waterlines.
Code of Federal Regulations, 2010 CFR
2010-07-01
....4261 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention... located at underground shaft stations and are part of the mine's fire protection system shall have at...
2012-06-27
ISS031-E-146344 (27 June 2012) --- An Expedition 31 crew member aboard the International Space Station, flying approximately 240 miles above Earth, recorded a series of images of the current wild fires in the southwestern United States. For this particular image, taken from the station?s Cupola, he used a 16mm lens, which gives this view a ?fisheye? affect. The fires give rise to thick smoke plumes on the southernmost extremity of the Wyoming Range, which occupies the center of the image. Slopes of the central Salt River Range appear at left. Three helicopters and more than 100 personnel are fighting the fire, which is being managed by the Bridger?Teton National Forest.
NASA Astrophysics Data System (ADS)
Soja, Amber; Westberg, David; Stackhouse, Paul, Jr.; McRae, Douglas; Jin, Ji-Zhong; Sukhinin, Anatoly
2010-05-01
Fire is the dominant disturbance that precipitates ecosystem change in boreal regions, and fire is largely under the control of weather and climate. Fire frequency, fire severity, area burned and fire season length are predicted to increase in boreal regions under current climate change scenarios. Therefore, changes in fire regimes have the potential to compel ecological change, moving ecosystems more quickly towards equilibrium with a new climate. The ultimate goal of this research is to assess the viability of large-scale (1°) data to be used to define fire weather danger and fire regimes, so that large-scale data can be confidently used to predict future fire regimes using large-scale fire weather data, like that available from current Intergovernmental Panel on Climate Change (IPCC) climate change scenarios. In this talk, we intent to: (1) evaluate Fire Weather Indices (FWI) derived using reanalysis and interpolated station data; (2) discuss the advantages and disadvantages of using these distinct data sources; and (3) highlight established relationships between large-scale fire weather data, area burned, active fires and ecosystems burned. Specifically, the Canadian Forestry Service (CFS) Fire Weather Index (FWI) will be derived using: (1) NASA Goddard Earth Observing System version 4 (GEOS-4) large-scale reanalysis and NASA Global Precipitation Climatology Project (GPCP) data; and National Climatic Data Center (NCDC) surface station-interpolated data. Requirements of the FWI are local noon surface-level air temperature, relative humidity, wind speed, and daily (noon-noon) rainfall. GEOS-4 reanalysis and NCDC station-interpolated fire weather indices are generally consistent spatially, temporally and quantitatively. Additionally, increased fire activity coincides with increased FWI ratings in both data products. Relationships have been established between large-scale FWI to area burned, fire frequency, ecosystem types, and these can be use to estimate historic and future fire regimes.
Mark A. Finney; Charles W. McHugh; Roberta Bartlette; Kelly Close; Paul Langowski
2003-01-01
This report summarizes the progress of the Hayman Fire, its behavior, and the influence of environmental conditions. Data were obtained from narratives from fire behavior analysts assigned to the fire management teams, discussions with fire management staff, meteorology from local weather stations and Bradshaw and others (2003), photographs, satellite imagery, and...
Monthly fire behavior patterns
Mark J. Schroeder; Craig C. Chandler
1966-01-01
From tabulated frequency distributions of fire danger indexes for a nationwide network of 89 stations, the probabilities of four types of fire behavior ranging from 'fire out' to 'critical' were calculated for each month and are shown in map form.
Remote sensing of fire and deforestation in the tropics from the International Space Station
NASA Astrophysics Data System (ADS)
Hoffman, James W.; Riggan, Philip J.; Brass, James A.
2000-01-01
In August of 1999 over 30,000 fire counts were registered by the Advanced Very High Resolution Radiometer aboard NOAA satellites over central Brazil, and an extensive smoke pall produced a health hazard and hindered commercial aviation across large portions of the states of Mato Grosso and Mato Grosso do Sul. Clearly fire was an important part of the Brazilian environment, but limitations in satellite and airborne remote sensing prevented a clear picture of what was burning, how much biomass was consumed, where the most critical resources were threatened, or exactly what was the global environmental impact. Another important problem that must be addressed is the deforestation of the rain forest by unauthorized logging operations. To detect these illegal clear cutting activities, continuous, high resolution monitoring must be initiated. The low altitude Space Station offers an ideal platform from which to monitor the tropical regions for both fires and deforestation from an equatorial orbit. A new micro-bolometer-based thermal imager, the FireMapper, has been designed to provide a solution for these problems in fire and resource monitoring. In this paper we describe potential applications of the FireMapper aboard the International Space Station for demonstration of space-borne fire detection and measurement. .
Earthquake Warning Performance in Vallejo for the South Napa Earthquake
NASA Astrophysics Data System (ADS)
Wurman, G.; Price, M.
2014-12-01
In 2002 and 2003, Seismic Warning Systems, Inc. installed first-generation QuakeGuardTM earthquake warning devices at all eight fire stations in Vallejo, CA. These devices are designed to detect the P-wave of an earthquake and initiate predetermined protective actions if the impending shaking is estimated at approximately Modifed Mercalli Intensity V or greater. At the Vallejo fire stations the devices were set up to sound an audio alert over the public address system and to command the equipment bay doors to open. In August 2014, after more than 11 years of operating in the fire stations with no false alarms, the five units that were still in use triggered correctly on the MW 6.0 South Napa earthquake, less than 16 km away. The audio alert sounded in all five stations, providing fire fighters with 1.5 to 2.5 seconds of warning before the arrival of the S-wave, and the equipment bay doors opened in three of the stations. In one station the doors were disconnected from the QuakeGuard device, and another station lost power before the doors opened completely. These problems highlight just a small portion of the complexity associated with realizing actionable earthquake warnings. The issues experienced in this earthquake have already been addressed in subsequent QuakeGuard product generations, with downstream connection monitoring and backup power for critical systems. The fact that the fire fighters in Vallejo were afforded even two seconds of warning at these epicentral distances results from the design of the QuakeGuard devices, which focuses on rapid false positive rejection and ground motion estimates. We discuss the performance of the ground motion estimation algorithms, with an emphasis on the accuracy and timeliness of the estimates at close epicentral distances.
Fire, Fuel, and Smoke Science Program 2015 Research Accomplishments
Faith Ann Heinsch; Charles W. McHugh; Colin C. Hardy
2016-01-01
The Fire, Fuel, and Smoke Science Program (FFS) of the U.S. Forest Service, Rocky Mountain Research Station focuses on fundamental and applied research in wildland fire, from fire physics and fire ecology to fuels management and smoke emissions. Located at the Missoula Fire Sciences Laboratory in Montana, the scientists, engineers, technicians, and support...
49 CFR 192.171 - Compressor stations: Additional safety equipment.
Code of Federal Regulations, 2010 CFR
2010-10-01
... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Design of... must have adequate fire protection facilities. If fire pumps are a part of these facilities, their... event of inadequate cooling or lubrication of the unit. (d) Each compressor station gas engine that...
2000-09-14
KENNEDY SPACE CENTER, FLA. -- Firefighters surround a burning simulated aircraft during training exercises Cape Canaveral Air Force Station Pad 30. Those at left wait their turn as the crew on the right turn their hoses toward the fire. The firefighters are with Fire and Emergency Services at the Naval Station Mayport, Fla
2000-09-14
KENNEDY SPACE CENTER, FLA. -- Firefighters surround a burning simulated aircraft during training exercises Cape Canaveral Air Force Station Pad 30. Those at left wait their turn as the crew on the right turn their hoses toward the fire. The firefighters are with Fire and Emergency Services at the Naval Station Mayport, Fla
2010-09-20
ISS024-E-015121 (20 Sept. 2010) --- Twitchell Canyon Fire in central Utah is featured in this image photographed by an Expedition 24 crew member on the International Space Station (ISS). The Twitchell Canyon Fire near central Utah?s Fishlake National Forest is reported to have an area of approximately 13,383 hectares (approximately 134 square kilometers, or 33,071 acres). This detailed image shows smoke plumes generated by several fire spots close to the southwestern edge of the burned area. The fire was started by a lightning strike on July 20, 2010. Whereas many of the space station images of Earth are looking straight down (nadir), this photograph was exposed at an angle. The space station was located over a point approximately 509 kilometers (316 miles) to the northeast, near the Colorado/Wyoming border, at the time the image was taken on Sept. 20. Southwesterly winds were continuing to extend smoke plumes from the fire to the northeast. While the Twitchell Canyon region is sparsely populated, Interstate Highway 15 is visible at upper left.
Infrared fiber-optic fire sensors - Concepts and designs for Space Station applications
NASA Technical Reports Server (NTRS)
Tapphorn, Ralph M.; Porter, Alan R.
1990-01-01
Various design configurations used for testing IR fiber-optic (IFO) fire-sensor concepts are presented. Responsibility measurements conducted to select the best concept are reviewed. The results indicate that IFO fire-sensor systems based on distributed fiber sensors are feasible for future aerospace applications. For Space Station Freedom, these systems offer alternative fire detectors for monitoring areas within equipment or stage compartments where the ventilation may be inadequate for proper operation of smoke detectors. They also allow a large number of areas to be monitored by a single central detector unit, which reduces the associated cost and weight.
15. "FIRING CONTROL BLOCKHOUSE; STATION '0' AREA; PLAN, AND SECTIONS." ...
15. "FIRING CONTROL BLOCKHOUSE; STATION '0' AREA; PLAN, AND SECTIONS." Specifications No. ENG-04-353-57-75; Drawing No. AF-60-09-15; sheet 40 of 96; D.O. Series No. AF 1394/60, Rev. A. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 5296 Rev. A, Date: 11/17/59. - Edwards Air Force Base, South Base Sled Track, Firing Control Blockhouse, South of Sled Track at east end, Lancaster, Los Angeles County, CA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grier, H.E.
1985-09-01
An automatic remote-control system armed and fired the bomb and sent out a sequence of time signals to experimental equipment on the atoll. A central station at Parry Island sent signals via submarine cables to a timer station on a shot island. The timer station controlled signals to the zero station and to experiments on the island, and through auxiliary stations, it also controlled signal distribution on adjacent islands. Light-sensitive triggering units for apparatus and for accurate standard zero-time reference were provided in the form of Blue Boxes, or fiducial markers.
46 CFR 78.45-1 - When required.
Code of Federal Regulations, 2012 CFR
2012-10-01
... the following plans: (1) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
46 CFR 78.45-1 - When required.
Code of Federal Regulations, 2010 CFR
2010-10-01
... the following plans: (1) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
46 CFR 78.45-1 - When required.
Code of Federal Regulations, 2011 CFR
2011-10-01
... the following plans: (1) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
46 CFR 78.45-1 - When required.
Code of Federal Regulations, 2013 CFR
2013-10-01
... the following plans: (1) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
46 CFR 78.45-1 - When required.
Code of Federal Regulations, 2014 CFR
2014-10-01
... the following plans: (1) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
Fire, Fuel, and Smoke Program: 2014 Research Accomplishments
Faith Ann Heinsch; Robin J. Innes; Colin C. Hardy; Kristine M. Lee
2015-01-01
The Fire, Fuel, and Smoke Science Program (FFS) of the U.S. Forest Service, Rocky Mountain Research Station focuses on fundamental and applied research in wildland fire, from fire physics and fire ecology to fuels management and smoke emissions. Located at the Missoula Fire Sciences Laboratory in Montana, the scientists, engineers, technicians, and support staff in FFS...
Fire, Fuel, and Smoke Science Program: 2013 Research accomplishments
Faith Ann Heinsch; Robin J. Innes; Colin C. Hardy; Kristine M. Lee
2014-01-01
The Fire, Fuel, and Smoke Science Program (FFS) of the U.S. Forest Service, Rocky Mountain Research Station, focuses on fundamental and applied research in wildland fire, from fire physics and fire ecology to fuels management and smoke emissions. Located at the Missoula Fire Sciences Laboratory in Montana, the scientists, engineers, technicians, and support staff in...
Fire Modeling Institute: FY2012 Annual Report: Bridging scientists and managers
Robin J. Innes
2013-01-01
The Fire Modeling Institute (FMI) brings the best available fire and fuel science and technology developed throughout the research community to bear in fire-related management issues. Although located within the Fire, Fuel, and Smoke Science Program of the U.S. Forest Service Rocky Mountain Research Station, FMI is a national and international resource, serving fire...
14. "FIRING CONTROL BLOCKHOUSE; STATION '0' AREA; PLAN, ELEVATIONS, SECTION, ...
14. "FIRING CONTROL BLOCKHOUSE; STATION '0' AREA; PLAN, ELEVATIONS, SECTION, DETAIL AND SCHED." Specifications No. ENG-04-353-57-75; Drawing No. AF-60-09-15; sheet 21 of 96; D.O. Series No. AF 1394/39, Rev. A. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 5296 Rev. A, Date: 11/17/59. - Edwards Air Force Base, South Base Sled Track, Firing Control Blockhouse, South of Sled Track at east end, Lancaster, Los Angeles County, CA
2000-09-14
KENNEDY SPACE CENTER, FLA. -- A firefighter (right) holds a water hose in readiness as others enter a smoke-filled simulated aircraft. The activities are part of fire training exercises at Cape Canaveral Air Force Station Pad 30 for firefighters with Fire and Emergency Services at the Naval Station Mayport, Fla. The firefighters have already extinguished flames from the aircraft
2000-09-14
KENNEDY SPACE CENTER, FLA. -- A firefighter (right) holds a water hose in readiness as others enter a smoke-filled simulated aircraft. The activities are part of fire training exercises at Cape Canaveral Air Force Station Pad 30 for firefighters with Fire and Emergency Services at the Naval Station Mayport, Fla. The firefighters have already extinguished flames from the aircraft
4. Photocopy of photograph, U.S. Army, ca. 1943 (original print ...
4. Photocopy of photograph, U.S. Army, ca. 1943 (original print located at Rocky Mountain Arsenal, Commerce City, Colorado). R.M.A. - 312 - FIRE & POLICE STATION LOOKING N.E. - Rocky Mountain Arsenal, Fire Station, 80 feet North of December Seventh Avenue; 120 feet East of D Street, Commerce City, Adams County, CO
46 CFR 97.36-1 - When required.
Code of Federal Regulations, 2012 CFR
2012-10-01
... the vessel the following plans: (a) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
46 CFR 97.36-1 - When required.
Code of Federal Regulations, 2013 CFR
2013-10-01
... the vessel the following plans: (a) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
46 CFR 97.36-1 - When required.
Code of Federal Regulations, 2014 CFR
2014-10-01
... the vessel the following plans: (a) General arrangement plans showing for each deck the fire control stations, the various sections enclosed by fire-resisting bulkheads, together with particulars of the fire alarms, detecting systems, the sprinkler installation (if any), the fire extinguishing appliances, means...
Earth observations taken by the Expedition 12 crew
2005-11-15
ISS012-E-13692 (2 Jan. 2006) --- A Forest Fire in Ouachita National Wildlife Refuge, Louisiana is featured in this image photographed by an Expedition 12 crew member on the International Space Station. Dry conditions and high winds have led to numerous recent fire outbreaks throughout much of the southwestern and south-central USA. This image captures the smoke plume from a fire in the Upper Ouachita National Wildlife Refuge in northeastern Louisiana. Drought conditions have persisted for much of the past year, leading to an increased fuel load comprised of dried grasses, shrubs, and trees. The combination of high amounts of dry fuel and frequent high winds has stoked small point fires into widespread brush fires. The fires generating this minimum 25-kilometer smoke plume started at approximately 13:00 hours local time. This image was acquired approximately 3.5 hours later as the station passed over the Texas/Louisiana border to the southwest. The extent of the plume reflects the strong westerly winds that drove the fire eastwards and damaged an estimated 200-300 acres of the wildlife refuge. The striking illumination of the plume is caused by a very low sun angle (angle between the horizon and the Sun directly below the space station), but this also results in generally low illumination of other scene features such as agricultural fields.
Introducing GFWED: The Global Fire Weather Database
NASA Technical Reports Server (NTRS)
Field, R. D.; Spessa, A. C.; Aziz, N. A.; Camia, A.; Cantin, A.; Carr, R.; de Groot, W. J.; Dowdy, A. J.; Flannigan, M. D.; Manomaiphiboon, K.;
2015-01-01
The Canadian Forest Fire Weather Index (FWI) System is the mostly widely used fire danger rating system in the world. We have developed a global database of daily FWI System calculations, beginning in 1980, called the Global Fire WEather Database (GFWED) gridded to a spatial resolution of 0.5 latitude by 2-3 longitude. Input weather data were obtained from the NASA Modern Era Retrospective-Analysis for Research and Applications (MERRA), and two different estimates of daily precipitation from rain gauges over land. FWI System Drought Code calculations from the gridded data sets were compared to calculations from individual weather station data for a representative set of 48 stations in North, Central and South America, Europe, Russia,Southeast Asia and Australia. Agreement between gridded calculations and the station-based calculations tended to be most different at low latitudes for strictly MERRA based calculations. Strong biases could be seen in either direction: MERRA DC over the Mato Grosso in Brazil reached unrealistically high values exceeding DCD1500 during the dry season but was too low over Southeast Asia during the dry season. These biases are consistent with those previously identified in MERRAs precipitation, and they reinforce the need to consider alternative sources of precipitation data. GFWED can be used for analyzing historical relationships between fire weather and fire activity at continental and global scales, in identifying large-scale atmosphereocean controls on fire weather, and calibration of FWI-based fire prediction models.
FIRE SERVICE TRAINING, INSTRUCTOR'S MANUAL, BASIC COURSE.
ERIC Educational Resources Information Center
BERNDT, WILLIAM M.; AND OTHERS
INSTRUCTORS CAN USE THIS MANUAL IN CONDUCTING A 34-HOUR FIRE STATION OR TRAINING CENTER EXTENSION PROGRAM TO IMPROVE THE COMPETENCIES AND SKILLS OF LOCAL FIRE PERSONNEL IN THE SPECIALIZED FIELD OF FIRE SERVICE. IT WAS DEVELOPED BY A STATEWIDE COMMITTEE OF FIRE FIGHTING CONSULTANTS AND ADVISORY GROUPS. THE 26 TEACHING GUIDES PROVIDE INSTRUCTIONAL…
Children's Knowledge of Fire Safety: A Report for the New Zealand Fire Service.
ERIC Educational Resources Information Center
Constable, Cheryl; Renwick, Margery
The study reported in this document was conducted to measure the impact of the New Zealand Fire Service's new fire safety program on elementary school students. Firefighters in each fire station and voluntary fire brigade in New Zealand were responsible for arranging a visit to every elementary school within their area to present a learning…
Quantitative Risk Modeling of Fire on the International Space Station
NASA Technical Reports Server (NTRS)
Castillo, Theresa; Haught, Megan
2014-01-01
The International Space Station (ISS) Program has worked to prevent fire events and to mitigate their impacts should they occur. Hardware is designed to reduce sources of ignition, oxygen systems are designed to control leaking, flammable materials are prevented from flying to ISS whenever possible, the crew is trained in fire response, and fire response equipment improvements are sought out and funded. Fire prevention and mitigation are a top ISS Program priority - however, programmatic resources are limited; thus, risk trades are made to ensure an adequate level of safety is maintained onboard the ISS. In support of these risk trades, the ISS Probabilistic Risk Assessment (PRA) team has modeled the likelihood of fire occurring in the ISS pressurized cabin, a phenomenological event that has never before been probabilistically modeled in a microgravity environment. This paper will discuss the genesis of the ISS PRA fire model, its enhancement in collaboration with fire experts, and the results which have informed ISS programmatic decisions and will continue to be used throughout the life of the program.
Use of regionalisation approach to develop fire frequency curves for Victoria, Australia
NASA Astrophysics Data System (ADS)
Khastagir, Anirban; Jayasuriya, Niranjali; Bhuyian, Muhammed A.
2017-11-01
It is important to perform fire frequency analysis to obtain fire frequency curves (FFC) based on fire intensity at different parts of Victoria. In this paper fire frequency curves (FFCs) were derived based on forest fire danger index (FFDI). FFDI is a measure related to fire initiation, spreading speed and containment difficulty. The mean temperature (T), relative humidity (RH) and areal extent of open water (LC2) during summer months (Dec-Feb) were identified as the most important parameters for assessing the risk of occurrence of bushfire. Based on these parameters, Andrews' curve equation was applied to 40 selected meteorological stations to identify homogenous stations to form unique clusters. A methodology using peak FFDI from cluster averaged FFDIs was developed by applying Log Pearson Type III (LPIII) distribution to generate FFCs. A total of nine homogeneous clusters across Victoria were identified, and subsequently their FFC's were developed in order to estimate the regionalised fire occurrence characteristics.
Science and technology issues in spacecraft fire safety
NASA Technical Reports Server (NTRS)
Friedman, Robert; Sacksteder, Kurt R.
1987-01-01
The space station, a permanently-inhabited orbiting laboratory, places new demands on spacecraft fire safety. Long-duration missions may call for more-constrained fire controls, but the accessibility of the space station to a variety of users may call for less-restrictive measures. This paper discusses fire safety issues through a review of the state of the art and a presentation of key findings from a recent NASA Lewis Research Center Workshop. The subjects covered are the fundamental science of low-gravity combustion and the technology advances in fire detection, extinguishment, materials assessment, and atmosphere selection. Key concerns are for the adoption of a fire-safe atmosphere and the substitution for the effective but toxic extinguishant, halon 1301. The fire safety studies and reviews provide several recommendations for further action. One is the expanded research in combustion, sensors, and materials in the low-gravity environment of space. Another is the development of generalized fire-safety standards for spacecraft through cooperative endeavors with aerospace and outside Government and industry sources.
Effect of litter type upon fuel-moisture indicator stick values
W. L. Fons; C. M. Countryman
1950-01-01
Instructions for establishing fire-weather stations in Region 5 have usually specified that the fuel-moisture indicator sticks be placed over a bed of ponderosa pine needles. This specification was made to insure uniform ground-cover effect for all stations. Because ponderosa pine needles are not readily available in all areas of California fire control...
2012-06-27
ISS031-E-146343 (27 June 2012) --- An Expedition 31 crew member aboard the International Space Station, flying approximately 240 miles above Earth, recorded a series of images of the current wild fires in the west and southwestern United States. For this particular image, taken from the station?s Cupola, he used a 16mm lens, which gives this view a ?fisheye? affect. The fires give rise to thick smoke plumes on the southernmost extremity of the Wyoming Range, which occupies the bottom left portion of the image. Three helicopters and more than 100 personnel are fighting the fire, which is being managed by the Bridger?Teton National Forest. Part of a docked Russian Soyuz spacecraft and the Multi-Purpose Logistics Module (MPLM) are at lower right.
A suite of fire, fuels, and smoke management tools
Roger D. Ottmar; Clint S. Wright; Susan J. Prichard
2009-01-01
The Fire and Environmental Research Applications Team (FERA) of the Forest Service, Pacific Northwest Research Station, is an interdisciplinary team of scientists that conduct primary research on wildland fire and provide decision support for fire hazard and smoke management. The team is committed to providing easy-to-use tools that help managers in their fire and...
Effects of drought and fire on bird communities of the Kofa National Wildlife Refuge, Arizona
McCreedy, Chris; van Riper, Charles; Esque, Todd C.; Darrah, Abigail J.
2016-01-08
In chapter 2, we examine the effects of the King Valley fire on breeding and migrant birds within the Kofa NWR. This fire was caused by incendiary weapons testing within Yuma Proving Ground, south of the Kofa NWRboundary (Esque and others, 2013). We found large differences in spring migrant and breeding species abundance and richness between bird count stations within the 2005 King Valley fire zone and bird count stations immediately outside the fire perimeter. Habitat loss to fire, and the subsequent slow regeneration of a Sonoran Desert flora that is not well adapted to fire disturbance, is a recognized threat to bird populations (McCreedy and others, 2009; Latta, 1999), and of all Sonoran Desert wildlife, birds may be the most impacted by loss of perennial Sonoran Desert vegetation to fire (Esque and Schwalbe, 2002). We conclude that decreases in both breeding and migrant use of washes within burned areas will likely persist into the long term (>25 years) due to slow return rates of xeroriparian woodlands lost in the fire.
Operation Flambeau - civil defense experiment and support: eyewitness accounts of a mass fire
Clay P. Butler; Theodore G. Storey; Richard C. Rothermel; Michael Woolliscroft; Clive M. Countryman; A.M. Western; Abraham Broido; Thomas Y. Palmer
1969-01-01
Seven men skilled in fire research were stationed around the periphery of Flambeau Fire 760-12 and recorded visual impressions of its magnitude. Also, instrumental data were taken both inside the fire zone and outside, so that visual magnitudes of the mass fire may be compared with its measured physical parameters. Visual magnitudes for this fire were: Flame heights up...
46 CFR 167.55-5 - Marking of fire and emergency equipment.
Code of Federal Regulations, 2013 CFR
2013-10-01
.../2-inch red letters: “General Alarm—When Bell Rings Go to Your Station.” (c) Steam, foam or CO 2 fire smothering apparatus. Steam, foam or CO2 fire smothering apparatus shall be marked “Steam Fire Apparatus” or “Foam Fire Apparatus” or “CO2 Fire Apparatus”, as appropriate, in not less than 2-inch red letters. The...
46 CFR 167.55-5 - Marking of fire and emergency equipment.
Code of Federal Regulations, 2011 CFR
2011-10-01
.../2-inch red letters: “General Alarm—When Bell Rings Go to Your Station.” (c) Steam, foam or CO 2 fire smothering apparatus. Steam, foam or CO2 fire smothering apparatus shall be marked “Steam Fire Apparatus” or “Foam Fire Apparatus” or “CO2 Fire Apparatus”, as appropriate, in not less than 2-inch red letters. The...
46 CFR 167.55-5 - Marking of fire and emergency equipment.
Code of Federal Regulations, 2010 CFR
2010-10-01
.../2-inch red letters: “General Alarm—When Bell Rings Go to Your Station.” (c) Steam, foam or CO 2 fire smothering apparatus. Steam, foam or CO2 fire smothering apparatus shall be marked “Steam Fire Apparatus” or “Foam Fire Apparatus” or “CO2 Fire Apparatus”, as appropriate, in not less than 2-inch red letters. The...
46 CFR 167.55-5 - Marking of fire and emergency equipment.
Code of Federal Regulations, 2012 CFR
2012-10-01
.../2-inch red letters: “General Alarm—When Bell Rings Go to Your Station.” (c) Steam, foam or CO 2 fire smothering apparatus. Steam, foam or CO2 fire smothering apparatus shall be marked “Steam Fire Apparatus” or “Foam Fire Apparatus” or “CO2 Fire Apparatus”, as appropriate, in not less than 2-inch red letters. The...
46 CFR 167.55-5 - Marking of fire and emergency equipment.
Code of Federal Regulations, 2014 CFR
2014-10-01
.../2-inch red letters: “General Alarm—When Bell Rings Go to Your Station.” (c) Steam, foam or CO 2 fire smothering apparatus. Steam, foam or CO2 fire smothering apparatus shall be marked “Steam Fire Apparatus” or “Foam Fire Apparatus” or “CO2 Fire Apparatus”, as appropriate, in not less than 2-inch red letters. The...
14. View south from first level roof of firing pier. ...
14. View south from first level roof of firing pier. Pitched corrugated metal roof marks location of the frame approach connecting the firing pier to the shop (shown in left distance). - Naval Torpedo Station, Firing Pier, North end of Gould Island in Narragansett Bay, Newport, Newport County, RI
The Development of a Single Tank Tactical Exercise for Training M1 Tank Commanders
1987-06-01
Evaluate the Conduct of Training NL NL NS Fire an M250 Grenade Launcher S S NS Identify Adjoining Map Sheets S S NS Identify Terrain Features on a Map S S...the Commander’s Weapon Station Establish, Enter, and Leave a Radio Net Estimate Range Evaluate the Conduct of Training Fire an M250 Grenade Launcher...from the Commander’s Weapon S Station (CWS) Fire an M250 Smoke Grenade Launcher Set Headspace and Timing on a Caliber .50 M2 HB Machinegun Zero a
Development of a Global Fire Weather Database
NASA Technical Reports Server (NTRS)
Field, R. D.; Spessa, A. C.; Aziz, N. A.; Camia, A.; Cantin, A.; Carr, R.; de Groot, W. J.; Dowdy, A. J.; Flannigan, M. D.; Manomaiphiboon, K.;
2015-01-01
The Canadian Forest Fire Weather Index (FWI) System is the mostly widely used fire danger rating system in the world. We have developed a global database of daily FWI System calculations, beginning in 1980, called the Global Fire WEather Database (GFWED) gridded to a spatial resolution of 0.5 latitude by 2/3 longitude. Input weather data were obtained from the NASA Modern Era Retrospective- Analysis for Research and Applications (MERRA), and two different estimates of daily precipitation from rain gauges over land. FWI System Drought Code calculations from the gridded data sets were compared to calculations from individual weather station data for a representative set of 48 stations in North, Central and South America, Europe, Russia, Southeast Asia and Australia. Agreement between gridded calculations and the station-based calculations tended to be most different at low latitudes for strictly MERRA based calculations. Strong biases could be seen in either direction: MERRA DC over the Mato Grosso in Brazil reached unrealistically high values exceeding DCD1500 during the dry season but was too low over Southeast Asia during the dry season. These biases are consistent with those previously identified in MERRA's precipitation, and they reinforce the need to consider alternative sources of precipitation data. GFWED can be used for analyzing historical relationships between fire weather and fire activity at continental and global scales, in identifying large-scale atmosphere-ocean controls on fire weather, and calibration of FWI-based fire prediction models.
NASA Technical Reports Server (NTRS)
Rodriquez, Branelle; Graf, John; Carlile, Christie; Young, GIna
2012-01-01
The National Aeronautics and Space Administration (NASA) is developing a Fine Water Mist (FWM) Portable Fire Extinguisher (PFE) for use on the International Space Station (ISS). The ISS presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segment, and a carbon dioxide extinguisher in the United States Orbital Segments, which include Columbus and Kibo pressurized elements. Currently, there are operational concerns with the emergency breathing equipment and the carbon dioxide extinguisher. The toxicity of the carbon dioxide requires the crew members to have an oxygen supply present during a fire event, therefore inherently creating an unsafe environment. The FWM PFE extinguishes a fire without creating a hazardous breathing environment for crew members. The following paper will discuss the unique functional and performance requirements that have been levied on the FWM PFE, identify unique microgravity design considerations for liquid and gas systems, as well as discuss the NASA ISS specific fire standards that were developed to establish an acceptable portable fire extinguisher s performance.
Automatic forest-fire measuring using ground stations and Unmanned Aerial Systems.
Martínez-de Dios, José Ramiro; Merino, Luis; Caballero, Fernando; Ollero, Anibal
2011-01-01
This paper presents a novel system for automatic forest-fire measurement using cameras distributed at ground stations and mounted on Unmanned Aerial Systems (UAS). It can obtain geometrical measurements of forest fires in real-time such as the location and shape of the fire front, flame height and rate of spread, among others. Measurement of forest fires is a challenging problem that is affected by numerous potential sources of error. The proposed system addresses them by exploiting the complementarities between infrared and visual cameras located at different ground locations together with others onboard Unmanned Aerial Systems (UAS). The system applies image processing and geo-location techniques to obtain forest-fire measurements individually from each camera and then integrates the results from all the cameras using statistical data fusion techniques. The proposed system has been extensively tested and validated in close-to-operational conditions in field fire experiments with controlled safety conditions carried out in Portugal and Spain from 2001 to 2006.
Automatic Forest-Fire Measuring Using Ground Stations and Unmanned Aerial Systems
Martínez-de Dios, José Ramiro; Merino, Luis; Caballero, Fernando; Ollero, Anibal
2011-01-01
This paper presents a novel system for automatic forest-fire measurement using cameras distributed at ground stations and mounted on Unmanned Aerial Systems (UAS). It can obtain geometrical measurements of forest fires in real-time such as the location and shape of the fire front, flame height and rate of spread, among others. Measurement of forest fires is a challenging problem that is affected by numerous potential sources of error. The proposed system addresses them by exploiting the complementarities between infrared and visual cameras located at different ground locations together with others onboard Unmanned Aerial Systems (UAS). The system applies image processing and geo-location techniques to obtain forest-fire measurements individually from each camera and then integrates the results from all the cameras using statistical data fusion techniques. The proposed system has been extensively tested and validated in close-to-operational conditions in field fire experiments with controlled safety conditions carried out in Portugal and Spain from 2001 to 2006. PMID:22163958
Crew Exploration Vehicle Environmental Control and Life Support Fire Protection Approach
NASA Technical Reports Server (NTRS)
Lewis, John F.; Barido, Richard; Tuan, George C.
2007-01-01
As part of preparing for the Crew Exploration Vehicle (CEV), the National Aeronautics and Space Administration (NASA) worked on developing the requirements to manage the fire risk. The new CEV poses unique challenges to current fire protection systems. The size and configuration of the vehicle resembles the Apollo capsule instead of the current Space Shuttle or the International Space Station. The smaller free air volume and fully cold plated avionic bays of the CEV requires a different approach in fire protection than the ones currently utilized. The fire protection approach discussed in this paper incorporates historical lessons learned and fire detection and suppression system design philosophy spanning from Apollo to the International Space Station. Working with NASA fire and materials experts, this approach outlines the best requirements for both the closed out area of the vehicle, such as the avionics bay, and the crew cabin area to address the unique challenges due to the size and configuration of the CEV.
Training Effectiveness and Cost Iterative Technique (TECIT). Volume 2. Cost Effectiveness Analysis
1988-07-01
Moving Tank in a Field Exercise A The task cluster identified as tank commander’s station/tank gunnery and the sub-task of firing an M250 grenade launcher...Firing Procedures, Task Number 171-126-1028. I OBJECTIVE: Given an Ml tank with crew, loaded M250 I grenade launcher, the commander’s station powered up
30 CFR 77.1106 - Battery-charging stations; ventilation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Battery-charging stations; ventilation. 77.1106... COAL MINES Fire Protection § 77.1106 Battery-charging stations; ventilation. Battery-charging stations shall be located in well-ventilated areas. Battery-charging stations shall be equipped with reverse...
30 CFR 77.1106 - Battery-charging stations; ventilation.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Battery-charging stations; ventilation. 77.1106... COAL MINES Fire Protection § 77.1106 Battery-charging stations; ventilation. Battery-charging stations shall be located in well-ventilated areas. Battery-charging stations shall be equipped with reverse...
30 CFR 77.1106 - Battery-charging stations; ventilation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Battery-charging stations; ventilation. 77.1106... COAL MINES Fire Protection § 77.1106 Battery-charging stations; ventilation. Battery-charging stations shall be located in well-ventilated areas. Battery-charging stations shall be equipped with reverse...
30 CFR 77.1106 - Battery-charging stations; ventilation.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Battery-charging stations; ventilation. 77.1106... COAL MINES Fire Protection § 77.1106 Battery-charging stations; ventilation. Battery-charging stations shall be located in well-ventilated areas. Battery-charging stations shall be equipped with reverse...
30 CFR 77.1106 - Battery-charging stations; ventilation.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Battery-charging stations; ventilation. 77.1106... COAL MINES Fire Protection § 77.1106 Battery-charging stations; ventilation. Battery-charging stations shall be located in well-ventilated areas. Battery-charging stations shall be equipped with reverse...
2010-07-25
ISS024-E-009526 (25 July 2010) --- Dominic Point Fire in Montana is featured in this image photographed by an Expedition 24 crew member on the International Space Station. Lightning strikes in the forested mountains of the western United States, and human activities, can spark wild fires during the summer dry season. The Dominic Point Fire was first reported near 3:00 p.m. local time on July 25 2010. Approximately one hour later, the space station crew photographed the fire?s large smoke plume ? already extending at least eight kilometers to the east ? from orbit as they passed almost directly overhead. Forest Service fire crews, slurry bombers and helicopters were on the scene by that evening. The fire may have been started by a lightning strike, as there are no trails leading into the fire area located approximately 22 kilometers northeast of Hamilton, MT (according to local reports). As of July 26, 2010 the fire had burned approximately 283?405 hectares of the Bitterroot National Forest in western Montana. The fire is thought to have expanded quickly due to high temperatures, low humidity, and favorable winds with an abundance of deadfall ? dead trees and logs that provide readily combustible fuels ? in the area.
Medical events during the 2009 Los Angeles County Station Fire: lessons for wildfire EMS planning.
Squire, Benjamin; Chidester, Cathy; Raby, Stephanie
2011-01-01
Little is known about the types of injuries and medical problems encountered by fire department personnel during suppression of large campaign-type wildland fires. Such information could help to plan for response to medical incidents during future wildfires. To describe the injuries and medical problems experienced by firefighters during the 2009 Los Angeles County Station Fire. This was a retrospective analysis of case records of patients treated during the Los Angeles County Station Fire. Data were abstracted from two sources: the incident command medical tracking sheet and prehospital patient care reports (PCRs). The sample included 183 patient contacts, of which PCRs were available for 65. For the remaining 118 patients, data were abstracted from the incident command medical tracking sheet. The most common chief complaint was extremity injury, accounting for 44 patient contacts (24% of all patients), with smoke inhalation second, at 32 patient contacts (17%). Of the 65 patients with PCRs, 31 (52%) were treated with oxygen, 26 (40%) had intravenous (IV) lines started, and 15 (23%) received an IV fluid bolus. Half of the patients were transported to an emergency department (ED); the remainder were treated on scene or self-transported to a non-acute care facility. Most firefighter injuries and illnesses encountered during the Los Angeles Station Fire were minor. The prevalence of injuries observed should be taken into consideration in creation of protocols and mandatory equipment lists for fireline paramedics. Furthermore, advanced training for paramedics in the diagnosis and treatment of minor medical conditions may be useful.
Nuclear techniques for the on-line bulk analysis of carbon in coal-fired power stations.
Sowerby, B D
2009-09-01
Carbon trading schemes usually require large emitters of CO(2), such as coal-fired power stations, to monitor, report and be audited on their CO(2) emissions. The emission price provides a significant additional incentive for power stations to improve efficiency. In the present paper, previous work on the bulk determination of carbon in coal is reviewed and assessed. The most favourable method is that based on neutron inelastic scattering. The potential role of on-line carbon analysers in improving boiler efficiency and in carbon accounting is discussed.
Firefighter noise exposure during training activities and general equipment use.
Root, Kyle S; Schwennker, Catherine; Autenrieth, Daniel; Sandfort, Delvin R; Lipsey, Tiffany; Brazile, William J
2013-01-01
Multiple noise measurements were taken on 6 types of fire station equipment and 15 types of emergency response vehicle-related equipment used by firefighters during routine and emergency operations at 10 fire stations. Five of the six types of fire station equipment, when measured at a distance of one meter and ear level, emitted noise equal to or greater than 85 dBA, including lawn maintenance equipment, snow blowers, compressors, and emergency alarms. Thirteen of 15 types of equipment located on the fire engines emitted noise levels equal to or greater than 85 dBA, including fans, saws, alarms, and extrication equipment. In addition, noise measurements were taken during fire engine operations, including the idling vehicle, vehicle sirens, and water pumps. Results indicated that idling fire-engine noise levels were below 85 dBA; however, during water pump and siren use, noise levels exceeded 85 dBA, in some instances, at different locations around the trucks where firefighters would be stationed during emergency operations. To determine if the duration and use of fire fighting equipment was sufficient to result in overexposures to noise during routine training activities, 93 firefighter personal noise dosimetry samples were taken during 10 firefighter training activities. Two training activities per sampling day were monitored during each sampling event, for a mean exposure time of 70 min per day. The noise dosimetry samples were grouped based on job description to compare noise exposures between the different categories of job tasks commonly associated with fire fighting. The three job categories were interior, exterior, and engineering. Mean personal dosimetry results indicated that the average noise exposure was 78 dBA during the training activities that lasted 70 min on average. There was no significant difference in noise exposure between each of the three job categories. Although firefighters routinely use equipment and emergency response vehicles that can produce hazardous levels of noise, this study showed that the average noise levels experienced by firefighters was below generally accepted guidelines.
VIEW OF THE DISPATCH OFFICE IN BUILDING 331. ALL SITEWIDE ...
VIEW OF THE DISPATCH OFFICE IN BUILDING 331. ALL SITE-WIDE FIRE ALARM SIGNALS, INCLUDING ALL FIRE PHONES, FIRE PULL BOXES, HEAT AND SMOKE DETECTORS, AND SUPPRESSION SYSTEM FLOW ALARMS, ARE TRANSMITTED TO THE BUILDING 331 DISPATCHER'S OFFICE. (3/77) - Rocky Flats Plant, Vehicle Maintenance Garage & Fire Station, Golden, Jefferson County, CO
46 CFR 116.530 - Fire control plan.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Fire control plan. 116.530 Section 116.530 Shipping... and Embarkation Station Requirements § 116.530 Fire control plan. A fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers. The plan must show...
46 CFR 116.530 - Fire control plan.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Fire control plan. 116.530 Section 116.530 Shipping... and Embarkation Station Requirements § 116.530 Fire control plan. A fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers. The plan must show...
46 CFR 116.530 - Fire control plan.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Fire control plan. 116.530 Section 116.530 Shipping... and Embarkation Station Requirements § 116.530 Fire control plan. A fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers. The plan must show...
46 CFR 116.530 - Fire control plan.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Fire control plan. 116.530 Section 116.530 Shipping... and Embarkation Station Requirements § 116.530 Fire control plan. A fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers. The plan must show...
46 CFR 116.530 - Fire control plan.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Fire control plan. 116.530 Section 116.530 Shipping... and Embarkation Station Requirements § 116.530 Fire control plan. A fire control plan must be posted on the vessel in a location that is accessible and visible to all passengers. The plan must show...
Fire Modeling Institute 2011 Annual Report
Robin J. Innes
2012-01-01
The Fire Modeling Institute (FMI), a part of the Rocky Mountain Research Station, Fire, Fuel, and Smoke Science Program, provides a bridge between scientists and managers. The mission of FMI is to bring the best available science and technology developed throughout the research community to bear on fire-related management issues across the nation. Resource management...
75 FR 35437 - Notice of Request for Extension of a Currently Approved Information Collection
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-22
... from construction of a fire station with fire fighting and rescue equipment to financing a 911 emergency system. These facilities are designed to provide fire protection and emergency rescue services to... for a currently approved information collection in support of the program for Fire and Rescue Loans...
ZrP nanoplates based fire-fighting foams stabilizer
NASA Astrophysics Data System (ADS)
Zhang, Lecheng; Cheng, Zhengdong; Li, Hai
2015-03-01
Firefighting foam, as a significant innovation in fire protection, greatly facilitates extinguishments for liquid pool fire. Recently, with developments in LNG industry, high-expansion firefighting foams are also used for extinguishing LNG fire or mitigating LNG leakage. Foam stabilizer, an ingredient in fire-fighting foam, stabilizes foam bubbles and maintains desired foam volume. Conventional foam stabilizers are organic molecules. In this work, we developed a inorganic based ZrP (Zr(HPO4)2 .H2O, Zirconium phosphate) plates functionalized as firefighting foam stabilizer, improving firefighting foam performance under harsh conditions. Several tests were conducted to illustrate performance. The mechanism for the foam stabilization is also proposed. Artie McFerrin Department of Chemical Engineering, Texas A&M University, College Station, TX 77843, USA. Mary Kay O'Connor Process Safety Center, Texas A&M University, College Station, TX, 77843-3122
The National Fire Danger Rating System: Derivation of Spread Index for Eastern and Southern States
Ralph M. Nelson
1964-01-01
Presents standards for locating, operating, and maintaining forest fire danger stations in Eastern and Southern States. Includes tables and forms for deriving the Spread Index of the new National Fire-Danger Rating System.
Atmospheric Science Data Center
2015-11-25
FIRE_CI2_ETL_RADAR Project Title: FIRE II CIRRUS Discipline: ... Platform: Ground Station Instrument: Radar Spatial Coverage: (37.06, -95.34) Spatial ... Order Data Guide Documents: ETL_RADAR Guide Readme Files: Readme ETL_RADAR (PS) ...
Pettit performs a session of BASS Fire Safety Tests at the MSG
2012-03-30
ISS030-E-178648 (30 March 2012) --- NASA astronaut Don Pettit, Expedition 30 flight engineer, performs a session of Burning and Suppression of Solids (BASS) fire safety tests at the Microgravity Sciences Glovebox (MSG) in the International Space Station?s Destiny laboratory. BASS uses Smoke Point in Coflow Experiment (SPICE) equipment but burns solid fuel samples instead of gaseous jets.
Large UAS Operations in the NAS - The NASA 2007 Western States Fire Missions (WSFM)
NASA Technical Reports Server (NTRS)
Buoni, Gregory P.; Howell, Kathleen M.
2008-01-01
Objectives: Demonstrate capabilities of UAS to overfly and collect sensor data on wildfires throughout Western US. Demonstrate long-endurance mission capabilities (20+ hours). Image multiple fires (greater than 4 fires per mission), to showcase extendable mission configuration and ability to either linger over key fires or station over disparate regional fires. Deliver real-time imagery to (within 10-minutes of acquisition).
Spacecraft Fire Safety: A Human Space Flight Program Perspective
NASA Technical Reports Server (NTRS)
Pedley, Michael D.
2003-01-01
This paper presents viewgraphs on the International Space Station's fire safety program from a human space flight perspective. The topics include: 1) Typical Manned Spacecraft Materials; 2) Typical Flammable Hardware Protection; 3) Materials Flammability; 4) Fire Retardants; 5) Nonflammable Foam Cushion Material; 6) Electrical Wire and Cable; 7) Russian Solid-Fuel Oxygen Generator (SFOG); 8) GOX Ignition Mechanisms; 9) Fire Detection; and 10) Fire Suppression.
Station set requirements document. Volume 82: Fire support. Book 2: Preliminary functional fire plan
NASA Technical Reports Server (NTRS)
Gray, N. C.
1974-01-01
The fire prevention/protection requirements for all shuttle facility and ground support equipment are presented for the hazardous operations. These include: preparing the orbiter for launch, launch operations, landing operations, safing operations, and associated off-line activities.
46 CFR 78.47-23 - Supervised patrol stations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 3 2012-10-01 2012-10-01 false Supervised patrol stations. 78.47-23 Section 78.47-23... Fire and Emergency Equipment, Etc. § 78.47-23 Supervised patrol stations. (a) Each supervised patrol clock or key station shall be numbered. (b) [Reserved] ...
46 CFR 78.47-23 - Supervised patrol stations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 3 2011-10-01 2011-10-01 false Supervised patrol stations. 78.47-23 Section 78.47-23... Fire and Emergency Equipment, Etc. § 78.47-23 Supervised patrol stations. (a) Each supervised patrol clock or key station shall be numbered. (b) [Reserved] ...
46 CFR 78.47-23 - Supervised patrol stations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 3 2010-10-01 2010-10-01 false Supervised patrol stations. 78.47-23 Section 78.47-23... Fire and Emergency Equipment, Etc. § 78.47-23 Supervised patrol stations. (a) Each supervised patrol clock or key station shall be numbered. (b) [Reserved] ...
Introducing the Global Fire WEather Database (GFWED)
NASA Astrophysics Data System (ADS)
Field, R. D.
2015-12-01
The Canadian Fire Weather Index (FWI) System is the mostly widely used fire danger rating system in the world. We have developed a global database of daily FWI System calculations beginning in 1980 called the Global Fire WEather Database (GFWED) gridded to a spatial resolution of 0.5° latitude by 2/3° longitude. Input weather data were obtained from the NASA Modern Era Retrospective-Analysis for Research (MERRA), and two different estimates of daily precipitation from rain gauges over land. FWI System Drought Code calculations from the gridded datasets were compared to calculations from individual weather station data for a representative set of 48 stations in North, Central and South America, Europe, Russia, Southeast Asia and Australia. Agreement between gridded calculations and the station-based calculations tended to be most different at low latitudes for strictly MERRA-based calculations. Strong biases could be seen in either direction: MERRA DC over the Mato Grosso in Brazil reached unrealistically high values exceeding DC=1500 during the dry season but was too low over Southeast Asia during the dry season. These biases are consistent with those previously-identified in MERRA's precipitation and reinforce the need to consider alternative sources of precipitation data. GFWED is being used by researchers around the world for analyzing historical relationships between fire weather and fire activity at large scales, in identifying large-scale atmosphere-ocean controls on fire weather, and calibration of FWI-based fire prediction models. These applications will be discussed. More information on GFWED can be found at http://data.giss.nasa.gov/impacts/gfwed/
Repeated Habitat Disturbances by Fire Decrease Local Effective Population Size
Ragsdale, Alexandria K.; McCoy, Earl D.; Mushinsky, Henry R.
2016-01-01
Effective population size is a fundamental parameter in population genetics, and factors that alter effective population size will shape the genetic characteristics of populations. Habitat disturbance may have a large effect on genetic characteristics of populations by influencing immigration and gene flow, particularly in fragmented habitats. We used the Florida Sand Skink (Plestiodon reynoldsi) to investigate the effect of fire-based habitat disturbances on the effective population size in the highly threatened, severely fragmented, and fire dependent Florida scrub habitat. We screened 7 microsatellite loci in 604 individuals collected from 12 locations at Archbold Biological Station. Archbold Biological Station has an active fire management plan and detailed records of fires dating to 1967. Our objective was to determine how the timing, number, and intervals between fires affect effective population size, focusing on multiple fires in the same location. Effective population size was higher in areas that had not been burned for more than 10 years and decreased with number of fires and shorter time between fires. A similar pattern was observed in abundance: increasing abundance with time-since-fire and decreasing abundance with number of fires. The ratio of effective population size to census size was higher at sites with more recent fires and tended to decrease with time-since-last-fire. These results suggest that habitat disturbances, such as fire, may have a large effect in the genetic characteristics of local populations and that Florida Sand Skinks are well adapted to the natural fire dynamics required to maintain Florida scrub. PMID:26976940
A study of forest fire danger district division in Lushan Mountain based on RS and GIS
NASA Astrophysics Data System (ADS)
Xiao, Jinxiang; Huang, Shu-E.; Zhong, Anjian; Zhu, Biqin; Ye, Qing; Sun, Lijun
2009-09-01
The study selected 9 factors, average maximum temperature, average temperature, average precipitation, average the longest days of continuous drought and average wind speed during fire prevention period, vegetation type, altitude, slope and aspect as the index of forest fire danger district division, which has taken the features of Lushan Mountain's forest fire history into consideration, then assigned subjective weights to each factor according to their sensitivity to fire or their fire-inducing capability. By remote sensing and GIS, vegetation information layer were gotten from Landsat TM image and DEM with a scale of 1:50000 was abstracted from the digital scanned relief map. Topography info. (elevation, slope, aspect) layers could be gotten after that. A climate resource databank that contained the data from the stations of Lushan Mountain and other nearby 7 stations was built up and extrapolated through the way of grid extrapolation in order to make the distribution map of climate resource. Finally synthetical district division maps were made by weighing and integrating all the single factor special layers,and the study area were divided into three forest fire danger district, include special fire danger district, I-fire danger district and II-fire danger district. It could be used as a basis for developing a forest fire prevention system, preparing the annual investment plan, allocating reasonably the investment of fire prevention, developing the program of forest fire prevention and handle, setting up forest fire brigade, leaders' decisions on forest fire prevention work.
Firefighters from Mayport Naval Station train at CCAFS
NASA Technical Reports Server (NTRS)
2000-01-01
Firefighters in full gear wait to approach a burning simulated aircraft during training exercises at Cape Canaveral Air Force Station Pad 30. The firefighters are with the Fire and Emergency Services at the Naval Station Mayport, Fla.
Paul Sopko; Larry Bradshaw; Matt Jolly
2016-01-01
The Wildland Fire Assessment System (WFAS, www.wfas.net) is a one-stop-shop giving wildland fire managers the ability to assess fire potential ranging in scale from national to regional and temporally from 1 to 5 days. Each day, broad-area maps are produced from fire weather station and lightning location networks. Three products are created using 24 hour...
Analysis of the Large Urban Fire Environment. Part 1. Theory
1982-07-01
the fire. It is the buoyancy-generated pressure forces, and not diffusive entrainment, that control the low-level induction of ambient air into the...18-- IV. RESULTS FLAMBEAU FIRES The multiple-fuel-bed Flambeau fires (Countryman, 1969; Palmer, 1981] were large, controlled burns conducted to...Station Northern Forest Fire Laboratory Alexandria, VA 22314 (12) Missoula, MT 59801 (1) Department of Defense 2. Mr. Clay F. Butler Command and Control
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-15
... facilities: New compressor station (Redd Farm Compressor Station) on Columbia's existing Line 1570 in... setting; Modifications to the Smithfield Compressor Station consisting of upgrades to the existing... coolers; Modifications to the Glenville Compressor Station by installing two gas-fired turbines, each...
Credit BG. Interior of Deluge Water Booster Station displaying highcapacity ...
Credit BG. Interior of Deluge Water Booster Station displaying high-capacity electrically driven water pumps for fire fighting service - Edwards Air Force Base, North Base, Deluge Water Booster Station, Northeast of A Street, Boron, Kern County, CA
Comparative ratings of 1951 forest fire weather in western Oregon.
Owen P. Cramer; Robert Kirkpatrick
1951-01-01
The 1951 forest fire weather in western Oregon is generally conceded to have been unusually severe. In order to compare this season with others, this report uses a scheme for rating fire seasons recently developed by the Fire Research section of the Experiment Station, The rating is based on indices of three weather characteristics which generally control burning...
46 CFR 27.203 - What are the requirements for fire detection on towing vessels?
Code of Federal Regulations, 2014 CFR
2014-10-01
...— (a) Each detector, each control panel, and each fire alarm are approved under 46 CFR subpart 161.002...; (c) The system is arranged and installed so a fire in the engine room automatically sets off alarms... light; (2) Both an audible alarm to notify crew at the operating station of fire and visible alarms to...
46 CFR 27.203 - What are the requirements for fire detection on towing vessels?
Code of Federal Regulations, 2013 CFR
2013-10-01
...— (a) Each detector, each control panel, and each fire alarm are approved under 46 CFR subpart 161.002...; (c) The system is arranged and installed so a fire in the engine room automatically sets off alarms... light; (2) Both an audible alarm to notify crew at the operating station of fire and visible alarms to...
46 CFR 27.203 - What are the requirements for fire detection on towing vessels?
Code of Federal Regulations, 2011 CFR
2011-10-01
...— (a) Each detector, each control panel, and each fire alarm are approved under 46 CFR subpart 161.002...; (c) The system is arranged and installed so a fire in the engine room automatically sets off alarms... light; (2) Both an audible alarm to notify crew at the operating station of fire and visible alarms to...
46 CFR 27.203 - What are the requirements for fire detection on towing vessels?
Code of Federal Regulations, 2012 CFR
2012-10-01
...— (a) Each detector, each control panel, and each fire alarm are approved under 46 CFR subpart 161.002...; (c) The system is arranged and installed so a fire in the engine room automatically sets off alarms... light; (2) Both an audible alarm to notify crew at the operating station of fire and visible alarms to...
Measuring Ecological Effects of Prescribed Fire Using Birds as Indicators of Forest Conditions
Nathaniel E. Seavy; John D. Alexander
2006-01-01
To evaluate the ecological effects of prescribed fire, bird and vegetation surveys were conducted in four study areas of the Klamath National Forest where prescribed fires are being used for management. Bird and vegetation data were collected at sites treated with prescribed fire and nearby untreated control sites. Data were collected at stations from 2000 (pre-...
Fire weather and large fire potential in the northern Sierra Nevada
Brandon M. Collins
2014-01-01
Fuels, weather, and topography all contribute to observed fire behavior. Of these, weather is not only the most dynamic factor, it is the most likely to be directly influenced by climate change. In this study 40 years of daily fire weather observations from five weather stations across the northern Sierra Nevada were analyzed to investigate potential changes or trends...
Development of the International Space Station Fine Water Mist Portable Fire Extinguisher
NASA Technical Reports Server (NTRS)
Rodriquez, Branelle; Young, GIna
2013-01-01
The National Aeronautics and Space Administration (NASA) is developing a Fine Water Mist (FWM) Portable Fire Extinguisher (PFE) for use on the International Space Station (ISS). The ISS presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segments, and a carbon dioxide extinguisher in the United States Orbital Segments, which include Columbus and Kibo pressurized elements. Currently, there are operational and compatibility concerns with the emergency breathing equipment and the carbon dioxide extinguisher. ISS emergency response breathing equipment does not filter carbon dioxide; therefore, crew members are required to have an oxygen supply present during a fire event since the carbon dioxide PFE creates an unsafe breathing environment. The ISS program recommended a nontoxic fire extinguisher to mitigate this operational risk. The FWM PFE can extinguish a fire without creating a hazardous breathing environment for crewmembers. This paper will discuss the unique functional and performance requirements that have been levied on the FWM PFE, identify unique microgravity design considerations for liquid and gas systems, and discuss the NASA ISS specific fire standards that were developed to establish an acceptable portable fire extinguisher s performance.
Atmospheric Science Data Center
2014-05-15
... title: Smoke from Station Fire Blankets Southern California View Larger Image ... that had not burned in decades, and years of extended drought contributed to the explosive growth of wildfires throughout southern ...
NASA Technical Reports Server (NTRS)
Rivas, Mauricio
2017-01-01
Ikhana demonstrates capabilities of UAS to overfly and collect sensor data on widespread fires throughout Western US and also demonstrate long-endurance mission capabilities (20-hours+). Ikhana images multiple fires (greater than 4 fires per mission), to showcase extendable mission configuration and ability to either linger over key fires or station over disparate regional fires. Ikhana also demonstrates new UAV-compatible, autonomous sensor for improved thermal characterization of fires. Also it provides automated, on-board, terrain and geo-rectified sensor imagery over the horizon SATCOM links to national fire personnel and Incident commanders.
7. ELEVATIONS OF FIRE EQUIPMENT BUILDING, SHEET 1 OF 2, ...
7. ELEVATIONS OF FIRE EQUIPMENT BUILDING, SHEET 1 OF 2, 8' X 10' NEGATIVE AND PRINT MADE FROM COPIES OF ORIGINAL PLANS, MAY 6, 1936, WALLOWA-WHITMAN NATIONAL FOREST SUPERVISOR'S OFFICE, BAKER CITY, OREGON. - Wallowa Ranger Station, Fire Equipment Building, 602 First Street, Wallowa, Wallowa County, OR
8. FLOOR PLANS OF FIRE EQUIPMENT BUILDING, SHEET 2 OF ...
8. FLOOR PLANS OF FIRE EQUIPMENT BUILDING, SHEET 2 OF 2, 8' X 10' NEGATIVE AND PRINT MADE FROM COPIES OF ORIGINAL PLANS, MAY 6, 1936, WALLOWA-WHITMAN NATIONAL FOREST SUPERVISOR'S OFFICE, BAKER CITY, OREGON. - Wallowa Ranger Station, Fire Equipment Building, 602 First Street, Wallowa, Wallowa County, OR
International Space Station (ISS)
2002-06-18
This is a photo of the Hayman Fire burning in the foothills southwest of Denver, Colorado, as viewed by an Expedition Five crewmember aboard the International Space Station (ISS). Astronauts use a variety of lenses and look angles as their orbits pass over the wildfires to document the long-distance movements of smoke from the fires as well as details of the burning areas. In this view, Littleton, Chatfield Lake, and the Arkansas River are all visible.
Repeated Habitat Disturbances by Fire Decrease Local Effective Population Size.
Schrey, Aaron W; Ragsdale, Alexandria K; McCoy, Earl D; Mushinsky, Henry R
2016-07-01
Effective population size is a fundamental parameter in population genetics, and factors that alter effective population size will shape the genetic characteristics of populations. Habitat disturbance may have a large effect on genetic characteristics of populations by influencing immigration and gene flow, particularly in fragmented habitats. We used the Florida Sand Skink (Plestiodon reynoldsi) to investigate the effect of fire-based habitat disturbances on the effective population size in the highly threatened, severely fragmented, and fire dependent Florida scrub habitat. We screened 7 microsatellite loci in 604 individuals collected from 12 locations at Archbold Biological Station. Archbold Biological Station has an active fire management plan and detailed records of fires dating to 1967. Our objective was to determine how the timing, number, and intervals between fires affect effective population size, focusing on multiple fires in the same location. Effective population size was higher in areas that had not been burned for more than 10 years and decreased with number of fires and shorter time between fires. A similar pattern was observed in abundance: increasing abundance with time-since-fire and decreasing abundance with number of fires. The ratio of effective population size to census size was higher at sites with more recent fires and tended to decrease with time-since-last-fire. These results suggest that habitat disturbances, such as fire, may have a large effect in the genetic characteristics of local populations and that Florida Sand Skinks are well adapted to the natural fire dynamics required to maintain Florida scrub. © The American Genetic Association. 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Firefighters from Mayport Naval Station train at CCAFS
NASA Technical Reports Server (NTRS)
2000-01-01
A firefighter waits for his companions before tackling the flames on a simulated aircraft. Firefighters with Fire and Emergency Services at the Naval Station Mayport, Fla., are taking part in training exercises at Cape Canaveral Air Force Station Pad 30.
View of Signal Corps Radar (S.C.R.) 296 Station 5 Transmitter ...
View of Signal Corps Radar (S.C.R.) 296 Station 5 Transmitter Building foundation, showing Fire Control Stations (Buildings 621 and 622) and concrete stairway (top left) camera facing southwest - Fort Barry, Signal Corps Radar 296, Station 5, Transmitter Building Foundation, Point Bonita, Marin Headlands, Sausalito, Marin County, CA
Fire suppression in human-crew spacecraft
NASA Technical Reports Server (NTRS)
Friedman, Robert; Dietrich, Daniel L.
1991-01-01
Fire extinguishment agents range from water and foam in early-design spacecraft (Halon 1301 in the present Shuttle) to carbon dioxide proposed for the Space Station Freedom. The major challenge to spacecraft fire extinguishment design and operations is from the micro-gravity environment, which minimizes natural convection and profoundly influences combustion and extinguishing agent effectiveness, dispersal, and post-fire cleanup. Discussed here are extinguishment in microgravity, fire-suppression problems anticipated in future spacecraft, and research needs and opportunities.
Rawhide Energy Station, Fort Collins, Colorado
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peltier, R.
2008-10-15
The staff of Platte River Power Authority's Rawhide Energy Station have been racking up operating stats and an environmental performance record that is the envy of other plant managers. In the past decade Rawhide has enjoyed an equivalent availability factor in the mid to high 90s and an average capacity factor approaching 90%. Still not content with this performance, Rawhide invested in new technology and equipment upgrades to further optimise performance, reduce emissions, and keep cost competitive. The Energy Station includes four GE France 7EA natural gas-fired turbines totalling 260 MW and a 274 MW coal-fired unit located in northeasternmore » Colorado. 7 figs.« less
Final Environmental Assessment: Proposed Fire Crash Rescue Station, Hill Air Force Base, Utah
2008-10-02
storage shed (Building 16) would be demolished and converted to parking ( see Figure 1 for the approximate locations). 1.3 Need for the Action The...existing facilities ( see Section 2.3.3.1), and other potential locations for siting the proposed fire crash rescue station ( see Section 2.3.3.2). 2.3...during scoping meetings, but eliminated from detailed consideration ( see Section 1.7.3) include: • geology and surface soils (seismicity, topography
2006-06-23
KENNEDY SPACE CENTER, FLA. - An overview of the new Firing Room 4 shows the expanse of computer stations and the various operations the facility will be able to manage. FR4 is now designated the primary firing room for all remaining shuttle launches, and will also be used daily to manage operations in the Orbiter Processing Facilities and for integrated processing for the shuttle. The firing room now includes sound-suppressing walls and floors, new humidity control, fire-suppression systems and consoles, support tables with computer stations, communication systems and laptop computer ports. FR 4 also has power and computer network connections and a newly improved Checkout, Control and Monitor Subsystem. The renovation is part of the Launch Processing System Extended Survivability Project that began in 2003. United Space Alliance's Launch Processing System directorate managed the FR 4 project for NASA. Photo credit: NASA/Dimitri Gerondidakis
Meteorological conditions affecting the Freeman Lake (Idaho) fire
George M. Jemison
1932-01-01
Measurements of meteorological conditions prevailing during the rapid spread of forest fires are greatly needed so that when their recurrence seems probable, fire-weather forecasters may issue warnings of the danger. Such determinations also can be used by forest protective agencies which operate meteorological stations to guide their own action in the distribution of...
19. Interior first level view looking north within forward (north) ...
19. Interior first level view looking north within forward (north) section of firing pier. Objects pictured include torpedo cart (left), floor-mounted roller tray (extending to lower right), and (at center rear), deck-type firing tube. - Naval Torpedo Station, Firing Pier, North end of Gould Island in Narragansett Bay, Newport, Newport County, RI
14 CFR 25.857 - Cargo compartment classification.
Code of Federal Regulations, 2012 CFR
2012-01-01
... detector or fire detector system to give warning at the pilot or flight engineer station. (c) Class C. A... compartment but in which— (1) There is a separate approved smoke detector or fire detector system to give... a separate approved smoke or fire detector system to give warning at the pilot or flight engineer...
14 CFR 25.857 - Cargo compartment classification.
Code of Federal Regulations, 2010 CFR
2010-01-01
... detector or fire detector system to give warning at the pilot or flight engineer station. (c) Class C. A... compartment but in which— (1) There is a separate approved smoke detector or fire detector system to give... a separate approved smoke or fire detector system to give warning at the pilot or flight engineer...
14 CFR 25.857 - Cargo compartment classification.
Code of Federal Regulations, 2013 CFR
2013-01-01
... detector or fire detector system to give warning at the pilot or flight engineer station. (c) Class C. A... compartment but in which— (1) There is a separate approved smoke detector or fire detector system to give... a separate approved smoke or fire detector system to give warning at the pilot or flight engineer...
14 CFR 25.857 - Cargo compartment classification.
Code of Federal Regulations, 2014 CFR
2014-01-01
... detector or fire detector system to give warning at the pilot or flight engineer station. (c) Class C. A... compartment but in which— (1) There is a separate approved smoke detector or fire detector system to give... a separate approved smoke or fire detector system to give warning at the pilot or flight engineer...
14 CFR 25.857 - Cargo compartment classification.
Code of Federal Regulations, 2011 CFR
2011-01-01
... detector or fire detector system to give warning at the pilot or flight engineer station. (c) Class C. A... compartment but in which— (1) There is a separate approved smoke detector or fire detector system to give... a separate approved smoke or fire detector system to give warning at the pilot or flight engineer...
28. CONTEXT VIEW OF BUILDING 229 (ELECTRIC POWER STATION) IN ...
28. CONTEXT VIEW OF BUILDING 229 (ELECTRIC POWER STATION) IN ASSEMBLY AREA WITH BUILDING 227 (FIRE STATION) IMMEDIATELY TO THE LEFT. - Loring Air Force Base, Weapons Storage Area, Northeastern corner of base at northern end of Maine Road, Limestone, Aroostook County, ME
Firefighters from Mayport Naval Station train at CCAFS
NASA Technical Reports Server (NTRS)
2000-01-01
During training exercises at Cape Canaveral Air Force Station Pad 30, firefighters with the Fire and Emergency Services at the Naval Station Mayport, Fla., wait while the NASA/USAF water carrier truck directs its water cannon toward a burning simulated aircraft (out of view).
49 CFR 192.167 - Compressor stations: Emergency shutdown.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Components § 192.167 Compressor stations: Emergency shutdown. (a) Except for unattended field compressor... fires, and electrical facilities in the vicinity of gas headers and in the compressor building, except that: (i) Electrical circuits that supply emergency lighting required to assist station personnel in...
49 CFR 192.167 - Compressor stations: Emergency shutdown.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Components § 192.167 Compressor stations: Emergency shutdown. (a) Except for unattended field compressor... fires, and electrical facilities in the vicinity of gas headers and in the compressor building, except that: (i) Electrical circuits that supply emergency lighting required to assist station personnel in...
Overview of ISS U.S. Fire Detection and Suppression System
NASA Technical Reports Server (NTRS)
Whitaker, Alana
2003-01-01
This paper presents a general overview of the International Space Station's Fire Detection and Suppression System. The topics include: 1) Introduction to Fire Detection and Suppression (FDS); 2) Description of (FDS) Subsystems; 3) FDS System Component Location and Status; 4) FDS System Capabilities; 5) FDS Automatic and Manual Response; 6) Post Fire Atmosphere Restoration and Air Quality Assessment; and 7) FDS Research Needs. This paper is in viewgraph form.
Smoke from Station Fire Blankets Southern California
2009-09-01
The Multi-angle Imaging SpectroRadiometer MISR instrument on NASA Terra satellite captured this Aug. 30 image of smoke plumes from the Station and other wildfires burning throughout Southern California.
46 CFR 28.325 - Fire detection systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... space must be equipped with an independent modular smoke detector or a smoke actuated fire detecting... detector must meet UL 217 and be listed as a “Single Station Smoke Detector—Also suitable for use in...
46 CFR 28.325 - Fire detection systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... space must be equipped with an independent modular smoke detector or a smoke actuated fire detecting... detector must meet UL 217 and be listed as a “Single Station Smoke Detector—Also suitable for use in...
46 CFR 28.325 - Fire detection systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... space must be equipped with an independent modular smoke detector or a smoke actuated fire detecting... detector must meet UL 217 and be listed as a “Single Station Smoke Detector—Also suitable for use in...
46 CFR 28.325 - Fire detection systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... space must be equipped with an independent modular smoke detector or a smoke actuated fire detecting... detector must meet UL 217 and be listed as a “Single Station Smoke Detector—Also suitable for use in...
46 CFR 28.325 - Fire detection systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... space must be equipped with an independent modular smoke detector or a smoke actuated fire detecting... detector must meet UL 217 and be listed as a “Single Station Smoke Detector—Also suitable for use in...
Fire in the OR--developing a fire safety plan.
McCarthy, Patricia M; Gaucher, Kenneth A
2004-03-01
Approximately 100 operating room fire occur each year in the United States. Although rare, fire in a perioperative setting can be disastrous for both patients and staff members. It is crucial that all perioperative departments have a well thought out and previously rehearsed fire plan in place. Multidisciplinary planning and implementation of regularly scheduled and scripted fire drills are essential to prevent adverse outcomes. Fire drills ensure that all staff members are familiar with the use and location of fire pull stations, fire extinguishers, and fire blankets. Fire drills also prepare staff members to evacuate the OR area if necessary. This article provides the information and framework necessary to develop and implement comprehensive OR fire safety plans that could make the difference between life and death in a fire emergency.
NASA Astrophysics Data System (ADS)
Valencia, J. M.; Sepúlveda, J.; Hoyos, C.; Herrera, L.
2017-12-01
Characterization and identification of fire and hailstorm events using weather radar data in a tropical complex topography region is an important task in risk management and agriculture. Polarimetric variables from a C-Band Dual polarization weather radar have potential uses in particle classification, due to the relationship their sensitivity to shape, spatial orientation, size and fall behavior of particles. In this sense, three forest fires and two chemical fires were identified for the Áburra Valley regions. Measurements were compared between each fire event type and with typical data radar retrievals for liquid precipitation events. Results of this analysis show different probability density functions for each type of event according to the particles present in them. This is very important and useful result for early warning systems to avoid precipitation false alarms during fire events within the study region, as well as for the early detection of fires using radar retrievals in remote cases. The comparative methodology is extended to hailstorm cases. Complementary sensors like laser precipitation sensors (LPM) disdrometers and meteorological stations were used to select dates of solid precipitation occurrence. Then, in this dates weather radar data variables were taken in pixels surrounding the stations and solid precipitation polar values were statistically compared with liquid precipitation values. Spectrum precipitation measured by LPM disdrometer helps to define typical features like particles number, fall velocities and diameters for both precipitation types. In addition, to achieve a complete hailstorm characterization, other meteorological variables were analyzed: wind field from meteorological stations and radar wind profiler, profiling data from Micro Rain Radar (MRR), and thermodynamic data from a microwave radiometer.
NASA Astrophysics Data System (ADS)
Yoon, S.; Won, M.; Jang, K.; Lim, J.
2016-12-01
As there has been a recent increase in the case of forest fires in North Korea descending southward through the De-Militarized Zone (DMZ), ensuring proper response to such events has been a challenge. Therefore, in order to respond and manage these forest fires appropriately, an improvement in the forest fire predictability through integration of mountain weather information observed at the most optimal site is necessary. This study is a proactive case in which a spatial analysis and an on-site assessment method were developed for selecting an optimum site for a mountain weather observation in national forest. For spatial analysis, the class 1 and 2 forest fire danger areas for the past 10 years, accessibility maximum 100m, Automatic Weather Station (AWS) redundancy within 2.5km, and mountain terrains higher than 200m were analyzed. A final overlay analysis was performed to select the candidates for the field assessment. The sites selected through spatial analysis were quantitatively evaluated based on the optimal meteorological environment, forest and hiking trail accessibility, AWS redundancy, and supply of wireless communication and solar powered electricity. The sites with total score of 70 and higher were accepted as adequate. At the final selected sites, an AMOS was established, and integration of mountain and Korea Meteorological Administration (KMA) weather data improved the forest fire predictability in South Korea by 10%. Given these study results, we expect that establishing an automatic mountain meteorology observation station at the optimal sites in inaccessible area and integrating mountain weather data will improve the predictability of forest fires.
Earth Observation - Forest Fire
2011-06-27
ISS028-E-010044 (27 June 2011) --- A crew member aboard the International Space Station, flying at an altitude of approximately 235 statute miles on June 27, 2011, exposed this still photograph of a major fire in the Jemez Mountains of the Santa Fe National Forest in north-central New Mexico. The fire is just southwest of Los Alamos National Laboratories.
Wildfire, research, and a climate station
Ward McCaughey
2008-01-01
In August, the human-caused Tin Cup Fire took off a few miles to the north of where the Fire Sciences Laboratory crew was busy collecting fuels data on the Trapper Bunkhouse study site west of Darby. The fire demonstrated how quickly wildfire can escape initial attack in untreated stands, especially under extremely dry conditions, and how treated areas helped moderate...
Natural phenomena exhibited by forest fires
J. S. Barrows
1961-01-01
Forest fire phenomena are presented through a series of motion pictures and 35 mm slides. These films have been taken by the staffs of the Southeastern, Pacific Southwest, and Intermountain Forest and Range Experiment Stations of the U. S. Forest Service and by Dr. Vincent J. Schaefer during the course of fire research activities. Both regular speed and time-lapse...
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Applicability. The provisions of this section shall apply to each owner or operator of the fossil fuel-fired... the fossil fuel-fired, steam-generating equipment at the NGS, or the auxiliary steam boilers at the... of fires in the boiler with fuel oil, to the time when the electrostatic precipitator is sufficiently...
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Applicability. The provisions of this section shall apply to each owner or operator of the fossil fuel-fired... the fossil fuel-fired, steam-generating equipment at the NGS, or the auxiliary steam boilers at the... of fires in the boiler with fuel oil, to the time when the electrostatic precipitator is sufficiently...
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Applicability. The provisions of this section shall apply to each owner or operator of the fossil fuel-fired... the fossil fuel-fired, steam-generating equipment at the NGS, or the auxiliary steam boilers at the... of fires in the boiler with fuel oil, to the time when the electrostatic precipitator is sufficiently...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-06
... Unit 1 structure. However, neither the diesel generator fire zone nor any OMAs related to the Unit 2 station blackout diesel generator were included in the licensee's request for exemptions. As a result, the... ``However, neither the diesel generator fire [DELETED (area)] zone * * *'' Response Fire zones are subsets...
41. 'Firing Pier, Second Floor Plan, Section No. 2,' submitted ...
41. 'Firing Pier, Second Floor Plan, Section No. 2,' submitted 29 December 1941 by John Brackett, Consulting Engineer, to Public Works Department, Bureau of Yards & Docks. PW Drawing 3867-46, Y&D Drawing 190841. Scale 1/4' = 1'. - Naval Torpedo Station, Firing Pier, North end of Gould Island in Narragansett Bay, Newport, Newport County, RI
42. 'Firing Pier, Second Floor Plan, Section No. 3,' submitted ...
42. 'Firing Pier, Second Floor Plan, Section No. 3,' submitted 29 December 1941 by John Brackett, Consulting Engineer, to Public Works Department, Bureau of Yards & Docks. PW Drawing 3868-46, Y&D Drawing 190842. Scale 1/4' = 1'. - Naval Torpedo Station, Firing Pier, North end of Gould Island in Narragansett Bay, Newport, Newport County, RI
36. 'Firing Pier, First Floor Plan, Section No. 1,' submitted ...
36. 'Firing Pier, First Floor Plan, Section No. 1,' submitted 29 December 1941 by John Brackett, Consulting Engineer, to Public Works Department, Bureau of Yards & Docks. PW Drawing 3862-46, Y&D Drawing 190836. Scale 1/4' = 1'. - Naval Torpedo Station, Firing Pier, North end of Gould Island in Narragansett Bay, Newport, Newport County, RI
43. 'Firing Pier, Third and Fourth Floors and Roof Plan,' ...
43. 'Firing Pier, Third and Fourth Floors and Roof Plan,' submitted 29 December 1941 by John Brackett, Consulting Engineer, to Public Works Department, Bureau of Yards & Docks. PW Drawing 3869-46, Y&D Drawing 190843. Scale 1/4' = 1'. - Naval Torpedo Station, Firing Pier, North end of Gould Island in Narragansett Bay, Newport, Newport County, RI
38. 'Firing Pier, First Floor Plan, Section No. 3,' submitted ...
38. 'Firing Pier, First Floor Plan, Section No. 3,' submitted 29 December 1941 by John Brackett, Consulting Engineer, to Public Works Department, Bureau of Yards & Docks. PW Drawing 3864-46, Y&D Drawing 190838. Scale 1/4' = 1'. - Naval Torpedo Station, Firing Pier, North end of Gould Island in Narragansett Bay, Newport, Newport County, RI
40. 'Firing Pier, Second Floor Plan, Section No. 1,' submitted ...
40. 'Firing Pier, Second Floor Plan, Section No. 1,' submitted 29 December 1941 by John Brackett, Consulting Engineer, to Public Works Department, Bureau of Yards & Docks. PW Drawing 3866-46, Y&D Drawing 190840. Scale 1/4' = 1'. - Naval Torpedo Station, Firing Pier, North end of Gould Island in Narragansett Bay, Newport, Newport County, RI
39. 'Firing Pier, First Floor Plan, Section No. 4,' submitted ...
39. 'Firing Pier, First Floor Plan, Section No. 4,' submitted 29 December 1941 by John Brackett, Consulting Engineer, to Public Works Department, Bureau of Yards & Docks. PW Drawing 3865-46, Y&D Drawing 190839. Scale 1/4' = 1'. - Naval Torpedo Station, Firing Pier, North end of Gould Island in Narragansett Bay, Newport, Newport County, RI
37. 'Firing Pier, First Floor Plan, Section No. 2,' submitted ...
37. 'Firing Pier, First Floor Plan, Section No. 2,' submitted 29 December 1941 by John Brackett, Consulting Engineer, to Public Works Department, Bureau of Yards & Docks. PW Drawing 3863-46, Y&D Drawing 190837. Scale 1/4' = 1. - Naval Torpedo Station, Firing Pier, North end of Gould Island in Narragansett Bay, Newport, Newport County, RI
Richard E. McArdle; Donald N. Matthews
1934-01-01
This number of Forest Research Motes is primarily for the forest fire protectionist. It consists of a number of very short articles, each of which gives the essence of the results of a study made recently by this Forest Experiment Station. These so-called fire studies which are represented herein by brief fragments are all part of an organized research program, having...
Who starts forest fires in Maine - and how?
Wayne G. Banks; Fred E. Holt
1966-01-01
In 1964 the Maine Forest Service, in cooperation with the Northeastern Forest Experiment Station, conducted intensive investigations of a systematically selected sample of the fires that occurred in the State that year. The immediate purpose was to determine precisely how the fires started and who or what started them, and to assemble relevant information about the...
DETAIL VIEW OF OPERATIONS MANAGEMENT ROOM, FIRING ROOM NO. 3, ...
DETAIL VIEW OF OPERATIONS MANAGEMENT ROOM, FIRING ROOM NO. 3, FACING NORTH - Cape Canaveral Air Force Station, Launch Complex 39, Launch Control Center, LCC Road, East of Kennedy Parkway North, Cape Canaveral, Brevard County, FL
DETAIL VIEW OF OPERATIONS MANAGEMENT ROOM, FIRING ROOM NO. 3, ...
DETAIL VIEW OF OPERATIONS MANAGEMENT ROOM, FIRING ROOM NO. 3, FACING SOUTHEAST - Cape Canaveral Air Force Station, Launch Complex 39, Launch Control Center, LCC Road, East of Kennedy Parkway North, Cape Canaveral, Brevard County, FL
DETAIL VIEW OF OPERATIONS MANAGEMENT ROOM, FIRING ROOM NO. 3, ...
DETAIL VIEW OF OPERATIONS MANAGEMENT ROOM, FIRING ROOM NO. 3, FACING EAST - Cape Canaveral Air Force Station, Launch Complex 39, Launch Control Center, LCC Road, East of Kennedy Parkway North, Cape Canaveral, Brevard County, FL
DETAIL VIEW OF OPERATIONS MANAGEMENT ROOM, FIRING ROOM NO. 4, ...
DETAIL VIEW OF OPERATIONS MANAGEMENT ROOM, FIRING ROOM NO. 4, FACING WEST - Cape Canaveral Air Force Station, Launch Complex 39, Launch Control Center, LCC Road, East of Kennedy Parkway North, Cape Canaveral, Brevard County, FL
DETAIL VIEW OF VIDEO MONITORS, FIRING ROOM NO. 2, FACING ...
DETAIL VIEW OF VIDEO MONITORS, FIRING ROOM NO. 2, FACING SOUTHWEST - Cape Canaveral Air Force Station, Launch Complex 39, Launch Control Center, LCC Road, East of Kennedy Parkway North, Cape Canaveral, Brevard County, FL
DETAIL VIEW OF VIDEO MONITORS, FIRING ROOM NO. 3, FACING ...
DETAIL VIEW OF VIDEO MONITORS, FIRING ROOM NO. 3, FACING SOUTH - Cape Canaveral Air Force Station, Launch Complex 39, Launch Control Center, LCC Road, East of Kennedy Parkway North, Cape Canaveral, Brevard County, FL
Minimization of Roll Firings for Optimal Propellant Maneuvers
NASA Astrophysics Data System (ADS)
Leach, Parker C.
Attitude control of the International Space Station (ISS) is critical for operations, impacting power, communications, and thermal systems. The station uses gyroscopes and thrusters for attitude control, and reorientations are normally assisted by thrusters on docked vehicles. When the docked vehicles are unavailable, the reduction in control authority in the roll axis results in frequent jet firings and massive fuel consumption. To improve this situation, new guidance and control schemes are desired that provide control with fewer roll firings. Optimal control software was utilized to solve for potential candidates that satisfied desired conditions with the goal of minimizing total propellant. An ISS simulation too was then used to test these solutions for feasibility. After several problem reformulations, multiple candidate solutions minimizing or completely eliminating roll firings were found. Flight implementation would not only save massive amounts of fuel and thus money, but also reduce ISS wear and tear, thereby extending its lifetime.
Brian Cooke; Jane Kapler Smith; Robin Innes; Janet Fryer; Kris Zouhar; Ilana Abrahamson; Shannon Murphy; Eva Masin
2015-01-01
The Rocky Mountain Research Stationâs Fire Effects Information System (FEIS) team synthesizes information about wildland fires, their history in U.S. ecosystems, and their effects on U.S. wildland plants, lichens, and animals. Found at www.feis-crs.org/feis/, FEIS publications can be used for many purposes, including land use planning, restoration and rehabilitation...
NASA Technical Reports Server (NTRS)
2002-01-01
This photograph taken from the International Space Station on June 7, 2002, shows the Copper Fire burning in the hills outside Los Angeles. Astronauts use a variety of lenses and look angles as their orbits pass over wildfires to document the long-distance movements of smoke from the fires as well as details of the burning areas. This image clearly illustrates the difficult, rugged terrain that firefighters must face when fighting these wildland fires.
Firefighters from Mayport Naval Station train at CCAFS
NASA Technical Reports Server (NTRS)
2000-01-01
Firefighters hold their hoses on a burning simulated aircraft, creating a rainbow. Watching at right (red uniform) and in the foreground are trainers. The training exercises for firefighters with Fire and Emergency Services at Naval Station Mayport, Fla., are being held at Cape Canaveral Air Force Station Pad 30.
View of building 11050 looking southeast. Naval Ordnance Test ...
View of building 11050 looking southeast. - Naval Ordnance Test Station Inyokern, China Lake Pilot Plant, Fire Station & Marine Barracks, D Street, at corner of 4th Street, China Lake, Kern County, CA
Promises of advanced technology realized at Martin
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swanekamp, R.
1996-09-01
The 2,488-MW Martin station is a gas/oil-fired facility that embodies today`s demand for flexible operations, technological advances, and reduced production costs. Martin station first rose up from the Everglades in the early 1980s, with the construction of two 814-MW oil-fired steam plants, Units 1 and 2. Natural-gas-firing capability was added to the balanced-draft, natural-circulation boilers in 1986, increasing the station`s fuel flexibility. Martin then leaped into the headlines in the early 1990s when it added combined-cycle (CC) Units 3 and 4. With this 860-MW expansion, FP and L boldly became the fleet leader for the advanced, 2350F-class 7FA gas turbines.more » Further pushing he technology envelope, the CC includes a three-pressure reheat steam system that raises net plant efficiency for Units 3 and 4 to 54%, on a lower-heating-value (LHV) basis. Incorporating the reheat cycle required significant redesign of the gas-turbine/heat-recovery steam generator (HRSG) train, in order to maintain a rapid startup capability without exceeding metallurgical limits. Perhaps even more important than the technological achievements, Martin stands out from the crowd for its people power, which ensured that the promises of advanced technology actually came to fruition. This station`s aggressive, empowered O and M team shows that you can pioneer technology, reduce operating costs, and deliver high availability--all at the same time.« less
Oliveira, Marta; Slezakova, Klara; Alves, Maria José; Fernandes, Adília; Teixeira, João Paulo; Delerue-Matos, Cristina; Pereira, Maria do Carmo; Morais, Simone
2017-02-05
This work characterizes levels of eighteen polycyclic aromatic hydrocarbons (PAHs) in the breathing air zone of firefighters during their regular work shift at eight Portuguese fire stations, and the firefighters' total internal dose by six urinary monohydroxyl metabolites (OH-PAHs). Total PAHs (ΣPAHs) concentrations varied widely (46.4-428ng/m 3 ), mainly due to site specificity (urban/rural) and characteristics (age and layout) of buildings. Airborne PAHs with 2-3 rings were the most abundant (63.9-95.7% ΣPAHs). Similarly, urinary 1-hydroxynaphthalene and 1-hydroxyacenaphthene were the predominant metabolites (66-96% ΣOH-PAHs). Naphthalene contributed the most to carcinogenic ΣPAHs (39.4-78.1%) in majority of firehouses; benzo[a]pyrene, the marker of carcinogenic PAHs, accounted with 1.5-10%. Statistically positive significant correlations (r≥0.733, p≤0.025) were observed between ΣPAHs and urinary ΣOH-PAHs for firefighters of four fire stations suggesting that, at these sites, indoor air was their major exposure source of PAHs. Firefighter's personal exposure to PAHs at Portuguese fire stations were well below the existent occupational exposure limits. Also, the quantified concentrations of post-shift urinary 1-hydroxypyrene in all firefighters were clearly lower than the benchmark level (0.5μmol/mol) recommended by the American Conference of Governmental Industrial Hygienists. Copyright © 2016 Elsevier B.V. All rights reserved.
Progress in Fire Detection and Suppression Technology for Future Space Missions
NASA Technical Reports Server (NTRS)
Friedman, Robert; Urban, David L.
2000-01-01
Fire intervention technology (detection and suppression) is a critical part of the strategy of spacecraft fire safety. This paper reviews the status, trends, and issues in fire intervention, particularly the technology applied to the protection of the International Space Station and future missions beyond Earth orbit. An important contribution to improvements in spacecraft fire safety is the understanding of the behavior of fires in the non-convective (microgravity) environment of Earth-orbiting and planetary-transit spacecraft. A key finding is the strong influence of ventilation flow on flame characteristics, flammability limits and flame suppression in microgravity. Knowledge of these flow effects will aid the development of effective processes for fire response and technology for fire suppression.
Grant J. Williamson; Lynda D. Prior; Matt Jolly; Mark A. Cochrane; Brett P. Murphy; David M. J. S. Bowman
2016-01-01
Climate dynamics at diurnal, seasonal and inter-annual scales shape global fire activity, although difficulties of assembling reliable fire and meteorological data with sufficient spatio-temporal resolution have frustrated quantification of this variability. Using Australia as a case study, we combine data from 4760 meteorological stations with 12 years of satellite-...
Owen P. Cramer
1958-01-01
Any agency engaged in forest-fire control needs accurate weather forecasts and systematic procedures for making the best use of predicted and reported weather information. This study explores the practicability of using several tabular and graphical aids for converting area forecasts and local observations of relative humidity and wind speed into predicted values for...
A Combined Water-Bromotrifluoromethane Crash-Fire Protection System for a T-56 Turbopropeller Engine
NASA Technical Reports Server (NTRS)
Campbell, John A.; Busch, Arthur M.
1959-01-01
A crash-fire protection system is described which will suppress the ignition of crash-spilled fuel that may be ingested by a T-56 turbo-propeller engine. This system includes means for rapidly extinguishing the combustor flame, means for cooling and inerting with water the hot engine parts likely to ignite engine ingested fuel, and means for blanketing with bromotrifluoromethane massive metal parts that may reheat after the engine stops rotating. Combustion-chamber flames were rapidly extinguished at the engine fuel nozzles by a fuel shutoff and drain valve. Hot engine parts were inerted and cooled by 42 pounds of water discharged at seven engine stations. Massive metal parts that could reheat were inerted with 10 pounds of bromotrifluoromethane discharged at two engine stations. Performance trials of the crash-fire protection system were conducted by bringing the engine up to takeoff temperature, actuating the crash-fire protection system, and then spraying fuel into the engine to simulate crash-ingested fuel. No fires occurred during these trials, although fuel was sprayed into the engine from 0.3 second to 15 minutes after actuating the crash-fire protection system.
Systems Study of an Automated Fire Weather Data System
NASA Technical Reports Server (NTRS)
Nishioka, K.
1974-01-01
A sensor system applicable to an automated weather station was developed. The sensor provides automated fire weather data which correlates with manual readings. The equipment and methods are applied as an aid to the surveillance and protection of wildlands from fire damage. The continuous readings provided by the sensor system make it possible to determine the periods of time that the wilderness areas should be closed to the public to minimize the possibilities of fire.
Expert systems applied to spacecraft fire safety
NASA Technical Reports Server (NTRS)
Smith, Richard L.; Kashiwagi, Takashi
1989-01-01
Expert systems are problem-solving programs that combine a knowledge base and a reasoning mechanism to simulate a human expert. The development of an expert system to manage fire safety in spacecraft, in particular the NASA Space Station Freedom, is difficult but clearly advantageous in the long-term. Some needs in low-gravity flammability characteristics, ventilating-flow effects, fire detection, fire extinguishment, and decision models, all necessary to establish the knowledge base for an expert system, are discussed.
29. Aerial photograph (1973) looking south across Gould Island. Firing ...
29. Aerial photograph (1973) looking south across Gould Island. Firing pier (still possessing third and fourth levels) in foreground. Pitched roof extending from south end of firing pier marks location of frame approach between pier and shop building (center rear) and power plant (to right of shop). Photo courtesy of Naval Undersea Warfare Center, Division Newport, Rhode Island. - Naval Torpedo Station, Firing Pier, North end of Gould Island in Narragansett Bay, Newport, Newport County, RI
Bioremediation for coal-fired power stations using macroalgae.
Roberts, David A; Paul, Nicholas A; Bird, Michael I; de Nys, Rocky
2015-04-15
Macroalgae are a productive resource that can be cultured in metal-contaminated waste water for bioremediation but there have been no demonstrations of this biotechnology integrated with industry. Coal-fired power production is a water-limited industry that requires novel approaches to waste water treatment and recycling. In this study, a freshwater macroalga (genus Oedogonium) was cultivated in contaminated ash water amended with flue gas (containing 20% CO₂) at an Australian coal-fired power station. The continuous process of macroalgal growth and intracellular metal sequestration reduced the concentrations of all metals in the treated ash water. Predictive modelling shows that the power station could feasibly achieve zero discharge of most regulated metals (Al, As, Cd, Cr, Cu, Ni, and Zn) in waste water by using the ash water dam for bioremediation with algal cultivation ponds rather than storage of ash water. Slow pyrolysis of the cultivated algae immobilised the accumulated metals in a recalcitrant C-rich biochar. While the algal biochar had higher total metal concentrations than the algae feedstock, the biochar had very low concentrations of leachable metals and therefore has potential for use as an ameliorant for low-fertility soils. This study demonstrates a bioremediation technology at a large scale for a water-limited industry that could be implemented at new or existing power stations, or during the decommissioning of older power stations. Copyright © 2015 Elsevier Ltd. All rights reserved.
Concentrating Solar Power Projects - Solar Electric Generating Station I |
fire in 1999 damaged the storage system and it was not replaced. Status Date: April 14, 2017 Photo with : 3 hour(s) Thermal Storage Description: Storage system was damaged by fire in 1999 and was not
VIEW OF COMPUTER/DATA COLLECTION AREA, SOUTH OF FIRING ROOM NO. ...
VIEW OF COMPUTER/DATA COLLECTION AREA, SOUTH OF FIRING ROOM NO. 3, FACING SOUTHEAST - Cape Canaveral Air Force Station, Launch Complex 39, Launch Control Center, LCC Road, East of Kennedy Parkway North, Cape Canaveral, Brevard County, FL
Risks, designs, and research for fire safety in spacecraft
NASA Technical Reports Server (NTRS)
Friedman, Robert; Sacksteder, Kurt R.; Urban, David
1991-01-01
Current fire protection for spacecraft relies mainly on fire prevention through the use of nonflammable materials and strict storage controls of other materials. The Shuttle also has smoke detectors and fire extinguishers, using technology similar to aircraft practices. While experience has shown that the current fire protection is adequate, future improvements in fire safety technology to meet the challenges of long duration space missions, such as the Space Station Freedom, are essential. All spacecraft fire protection systems, however, must deal with the unusual combustion characteristics and operational problems in the low gravity environment. The features of low gravity combustion that affect spacecraft fire safety, and the issues in fire protection for Freedom that must be addressed eventually to provide effective and conservative fire protection systems are discussed.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-09
... proposed Project would consist of the following: Compressor Station 205--Washington County, Iowa Construct and operate a new 3,550 hp gas-fired compressor unit at Natural's Compressor Station 205 located near... Natural's Compressor Station 205. Install new 10-inch-diameter meter. [[Page 69718
The +vbar breakout during approach to Space Station Freedom
NASA Technical Reports Server (NTRS)
Dunham, Scott D.
1993-01-01
A set of burn profiles was developed to provide bounding jet firing histories for a +vbar breakout during approaches to Space Station Freedom. The delta-v sequences were designed to place the Orbiter on a safe trajectory under worst case conditions and to try to minimize plume impingement on Space Station Freedom structure.
The impact of air pollution from the coal-fired Columbia Generating Station upon vegetation was investigated. Air monitoring of 03 and 02 documented levels that occurred before and with operation of the generating station. Field sampling of alfalfa, lichens, and white pines was u...
Automatic fire-extinguishing system for inhabited pressurized compartments of manned spacecraft
NASA Astrophysics Data System (ADS)
Bolodian, Ivan; Melikhov, Anatoliy; Tanklevskiy, Leonid
2017-06-01
There is an innovational fire-extinguishing technology implemented via equipage of inhabited pressurized modules of the space station "Mir" and compartments of the Russian segment of International space station by automatic fire extinguishing systems in an orbital flight. Fire-safety in inhabited pressurized compartments of spacecraft (further - InPC SC) became one of the most dangerous factors during an orbital flight after a number of fire-hazardous situations occurred in different countries during preparation and execution of spaceflights [1,2]. High fire-risk in InPC of manned SC is determined by the following specific peculiarities of a arrangement and usage conditions of these items: - atmosphere of inhabited compartments is considerably enriched with oxygen - up to 25-40%; - there are many structural non-metal materials (here and after - materials) in order to lower the weight of InPC SC, most part of these materials is combustible under a given concentration of oxygen (here and after - Cox) in the atmosphere of InPC SC; - ventilation flow (here and after - Vvf) under normal operation of ventilation means in InPC SC considerably increases a possibility of fast fire-spread in InPC. - inhabited pressurized compartments of SC are filled with electrical equipment, which elements during failures even in low-current circuits became fire sources in oxygen-rich atmosphere; - indoor spaces of inhabited pressurized compartments of SC, as a rule, have complicated figuration with isolated for usage of local fire extinguishing zones with elements of electrical devices.
2000-09-14
KENNEDY SPACE CENTER, FLA. -- Firefighters in full gear wait to approach a burning simulated aircraft during training exercises at Cape Canaveral Air Force Station Pad 30. The firefighters are with the Fire and Emergency Services at the Naval Station Mayport, Fla.
2000-09-14
KENNEDY SPACE CENTER, FLA. -- Firefighters in full gear wait to approach a burning simulated aircraft during training exercises at Cape Canaveral Air Force Station Pad 30. The firefighters are with the Fire and Emergency Services at the Naval Station Mayport, Fla.
Forest fire autonomous decision system based on fuzzy logic
NASA Astrophysics Data System (ADS)
Lei, Z.; Lu, Jianhua
2010-11-01
The proposed system integrates GPS / pseudolite / IMU and thermal camera in order to autonomously process the graphs by identification, extraction, tracking of forest fire or hot spots. The airborne detection platform, the graph-based algorithms and the signal processing frame are analyzed detailed; especially the rules of the decision function are expressed in terms of fuzzy logic, which is an appropriate method to express imprecise knowledge. The membership function and weights of the rules are fixed through a supervised learning process. The perception system in this paper is based on a network of sensorial stations and central stations. The sensorial stations collect data including infrared and visual images and meteorological information. The central stations exchange data to perform distributed analysis. The experiment results show that working procedure of detection system is reasonable and can accurately output the detection alarm and the computation of infrared oscillations.
Fire safety concerns in space operations
NASA Technical Reports Server (NTRS)
Friedman, Robert
1987-01-01
This paper reviews the state-of-the-art in fire control techniques and identifies important issues for continuing research, technology, and standards. For the future permanent orbiting facility, the space station, fire prevention and control calls for not only more stringent fire safety due to the long-term and complex missions, but also for simplified and flexible safety rules to accommodate the variety of users. Future research must address a better understanding of the microgravity space environment as it influences fire propagation and extinction and the application of the technology of fire detection, extinguishment, and material assessment. Spacecraft fire safety should also consider the adaptation of methods and concepts derived from aircraft and undersea experience.
Fire safety arrangement of inhabited pressurized compartments of manned spacecraft
NASA Astrophysics Data System (ADS)
Bolodian, Ivan; Melikhov, Anatoliy; Tanklevskiy, Leonid
2017-06-01
The article deals with innovative technical solutions that provide fire safety in inhabited pressurized compartments of manned spacecraft by means of a fireproof device of inhabited pressurized compartments via application of engineering means of fire prevention and fire spreading prevention by lowering fire load in an inhabited pressurized module up to the point when the maximum possible levels of fire factors in an inhabited pressurized compartment of a manned spacecraft are prevented. Represented technical solutions are used at the present time according to stated recommendations during provision of fire safety of equipment created by a number of Russian organizations for equipage of inhabited pressurized compartments of spacecraft of the Russian segment of International space station.
2014-09-11
Cape Canaveral, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, Fire and Rescue personnel salute or stand at attention as the American flag is raised during a ceremony held by Kennedy’s Fire and Rescue personnel. Kennedy Fire and Rescue Services commemorated the 13th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Photo credit: Jim Grossmann
2014-09-11
Cape Canaveral, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, Fire and Rescue personnel stand at attention as the American flag is raised during a ceremony held by Kennedy’s Fire and Rescue personnel. Kennedy Fire and Rescue Services commemorated the 13th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Photo credit: Jim Grossmann
2014-09-11
Cape Canaveral, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, Fire and Rescue personnel salute or stand at attention as the American flag is raised during a ceremony held by Kennedy’s Fire and Rescue personnel. Kennedy Fire and Rescue Services commemorated the 13th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Photo credit: Jim Grossmann
The report gives results of measurements of nitrous oxide (N2O) emissions from coal-fired utility boilers at three electric power generating stations. Six units were tested, two at each site, including sizes ranging from 165 to 700 MW. Several manufacturers and boiler firing type...
3. Credit BG. Interior view looks northeast (46°) at fire ...
3. Credit BG. Interior view looks northeast (46°) at fire pumps, valves, and emergency generator (powered by an internal combustion engine). - Edwards Air Force Base, North Base, Deluge Water Pumping Station, Near Second & D Streets, Boron, Kern County, CA
The fire research program at the Silas Little Experimental Forest, New Lisbon, New Jersey
Kenneth L. Clark; Nicholas Skowronski; Michael Gallagher
2014-01-01
In this chapter, we document the development and current research efforts of the fire research program at the Silas Little Experimental Forest of the Northern Research Station, USDA Forest Service, in the Pinelands of southern New Jersey. The 450,000-ha (1.1 million-acre) Pinelands National Reserve contains some of the most challenging fuel types for wildland fire...
Earth Observation - Forest Fire
2011-06-27
ISS028-E-010043 (27 June 2011) --- A crew member aboard the International Space Station, flying at an altitude of approximately 235 statute miles on June 27, 2011, exposed this still photograph of a major fire in the Jemez Mountains of the Santa Fe National Forest in north-central New Mexico. The fire is just southwest of Los Alamos National Laboratories, which can be seen just right of center.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River... Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U.S. Naval Air...) The regulations. (i) Through navigation of surface craft outside the target areas will be permitted at...
Wild Fire Computer Model Helps Firefighters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Canfield, Jesse
2012-09-04
A high-tech computer model called HIGRAD/FIRETEC, the cornerstone of a collaborative effort between U.S. Forest Service Rocky Mountain Research Station and Los Alamos National Laboratory, provides insights that are essential for front-line fire fighters. The science team is looking into levels of bark beetle-induced conditions that lead to drastic changes in fire behavior and how variable or erratic the behavior is likely to be.
Wild Fire Computer Model Helps Firefighters
Canfield, Jesse
2018-02-14
A high-tech computer model called HIGRAD/FIRETEC, the cornerstone of a collaborative effort between U.S. Forest Service Rocky Mountain Research Station and Los Alamos National Laboratory, provides insights that are essential for front-line fire fighters. The science team is looking into levels of bark beetle-induced conditions that lead to drastic changes in fire behavior and how variable or erratic the behavior is likely to be.
1. Photographic copy of fire alarm plan for Control and ...
1. Photographic copy of fire alarm plan for Control and Recording Center Building 4221/E-22, showing layout of rooms. California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering 'Edwards Test Station, Fire Alarm Plan, Bldg. E-22,' drawing no. EFA/11-1, December 15, 1961. - Jet Propulsion Laboratory Edwards Facility, Control & Recording Center, Edwards Air Force Base, Boron, Kern County, CA
Project Fire Model: Summary Progress Report, Period November 1, 1958 to April 30, 1960
W.L. Fons; H.D. Bruce; W.Y. Pong; S.S. Richards
1960-01-01
This report summarizes progress from November 1, 1958, to April 30, 1960, in a study conducted by the Pacific Southwest Forest and Range Experiment Station of the Forest Service in cooperation with the Office of Civil and Defense Mobilization. Called PROJECT FIRE MODEL for convenience, the project sought to develop and study a laboratory-scale fire which would...
Climate and forest fires in Montana and northern Idaho, 1909-1919
J. A. Larsen; C. C. Delavan
1922-01-01
The present report is a result of the study of the relation between climate and forest fires in Montana and northern Idaho. This region is designated as District I of the United States Forest Service. The data used are the weather records of the United States Weather Bureau for the regular and cooperative stations, and the detail fire reports of the United States...
Earth Observations taken by the Expedition 17 Crew
2008-07-04
ISS017-E-010310 (4 July 2008) --- The Piute fire in California is featured in this image photographed by an Expedition 17 crewmember on the International Space Station. The Piute fire, burning south of Lake Isabella in the Sequoia National Forest in the southern Sierra Nevada Mountains, is one of the more than 300 wildfires burning across the state of California. The fire started June 28 just north of Twin Oaks, California, and has burned nearly 14,000 acres so far. Current estimates by fire officials suggest the fire may not be brought under control for another two weeks.
Expedition 21 Crew Members participate in Fire Drill/OBT
2009-10-15
ISS021-E-007175 (15 Oct. 2009) --- European Space Agency astronaut Frank De Winne (left), Expedition 21 commander; and Canadian Space Agency astronaut Robert Thirsk, flight engineer, conduct an onboard training (OBT) fire drill in the Columbus laboratory of the International Space Station.
‘Rutpink’ (Scarlet Fire®) Kousa Dogwood
USDA-ARS?s Scientific Manuscript database
‘Rutpink’ is a new kousa dogwood (Cornus kousa) cultivar released from the woody ornamentals breeding program of the New Jersey Agricultural Experiment Station (NJAES) and Rutgers University and marketed under the name Scarlet Fire® dogwood (Fig. 1). It exhibits a moderately vigorous, upright growt...
2014-08-19
ISS040-E-103496 (19 Aug. 2014) --- On an unusually cloud-free day at the height of the dry season in Amazonia, several fires were burning, giving rise to a broad smoke pall easily seen from the International Space Station, photographed by an Expedition 40 crew member. Parts of the space station appear along the margins of the image. Against the backdrop of the dark green rainforest, several fires follow the major highway BR 163 (lower center of the image to the top left). Fires are set to clear patches of forest for agriculture, a process that reveals red-brown soils. A long line of new cleared patches snakes east from BR 163 towards the remote valley of the Rio Crepori. Extensive deforested areas in Brazil?s state of Mato Grosso appear as tan areas across the top of the image. Fires show the advance of deforestation into the state of Para, the area shown in most of this view. Para is now second after Mato Grosso in terms of deforestation acreage.
Wood River recovery project -- speed and cooperation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Franczak, D.F.; Santschi, M.F.; Sander, S.
1998-12-31
A unit trip is a situation avoided by power generators because it affects their bottom line. The ability to recover from the trip quickly, and restore MW generation is the desired goal. However, what do you do if you lose your unit to a disastrous fire? How do you recover from this situation? This will be the subject of this paper describing such an event which affected the Illinois Power Company`s (IPC) operation. IPC`s Wood River Power Station suffered a disastrous fire which knocked out the Station`s only two operable units--4 and 5. The fire was the result of amore » coal mill explosion and damaged beyond repair, the units control systems and operating capabilities. A total of 488 MW in generating capacity was lost at a time when the IPC system required all available generation now, and in the foreseeable future. This paper will describe the event, the immediate mobilization efforts, and the challenges of recovering both units in the most expedient time frame possible. The keys to the success of the recovery project will be described in detail.« less
Fire safety experiments on MIR Orbital Station
NASA Technical Reports Server (NTRS)
Egorov, S. D.; Belayev, A. YU.; Klimin, L. P.; Voiteshonok, V. S.; Ivanov, A. V.; Semenov, A. V.; Zaitsev, E. N.; Balashov, E. V.; Andreeva, T. V.
1995-01-01
The process of heterogeneous combustion of most materials under zero-g without forced motion of air is practically impossible. However, ventilation is required to support astronauts' life and cool equipment. The presence of ventilation flows in station compartments at accidental ignition can cause a fire. An additional, but exceedingly important parameter of the fire risk of solid materials under zero-g is the minimum air gas velocity at which the extinction of materials occurs. Therefore, the conception of fire safety can be based on temporarily lowering the intensity of ventilation and even turning it off. The information on the limiting conditions of combustion under natural conditions is needed from both scientific and practical points of view. It will enable us to judge the reliability of results of ground-based investigations and develop a conception of fire safety of inhabited sealed compartments of space stations to by provided be means of nontraditional and highly-effective methods without both employing large quantities of fire-extinguishing compounds and hard restrictions on use of polymers. In this connection, an experimental installation was created to study the process of heterogeneous combustion of solid non-metals and to determine the conditions of its extinction under microgravity. This installation was delivered to the orbital station 'Mir' and the cosmonauts Viktorenko and Kondakova performed initial experiments on it in late 1994. The experimental installation consists of a combustion chamber with an electrical systems for ignition of samples, a device for cleaning air from combustion products, an air suction unit, air pipes and a control panel. The whole experiment is controlled by telemetry and recorded with two video cameras located at two different places. Besides the picture, parameters are recorded to determine the velocity of the air flow incoming to the samples, the time points of switching on/off the devices, etc. The combustion chamber temperature is also controlled. The main objectives of experiments of this series were as follows: (1) verification of the reliability of the installation in orbital flight; (2) verification of the experimental procedure; and (3) investigation of combustion of two types of materials under microgravity at various velocities of the incoming air flow.
Oblique view of building 11050, showing east and south sides, ...
Oblique view of building 11050, showing east and south sides, looking northwest. - Naval Ordnance Test Station Inyokern, China Lake Pilot Plant, Fire Station & Marine Barracks, D Street, at corner of 4th Street, China Lake, Kern County, CA
2000-09-14
KENNEDY SPACE CENTER, FLA. -- A firefighter waits for his companions before tackling the flames on a simulated aircraft. Firefighters with Fire and Emergency Services at the Naval Station Mayport, Fla., are taking part in training exercises at Cape Canaveral Air Force Station Pad 30.
2000-09-14
KENNEDY SPACE CENTER, FLA. -- A firefighter waits for his companions before tackling the flames on a simulated aircraft. Firefighters with Fire and Emergency Services at the Naval Station Mayport, Fla., are taking part in training exercises at Cape Canaveral Air Force Station Pad 30.
2007 Western States Fire Mission
NASA Technical Reports Server (NTRS)
Howell, Kathleen
2008-01-01
A general overview of the Ikhana Uninhabited Air System (UAS) is presented. The contents include: 1) Ikhana UAS; 2) Ikhana UAS / Ground Control Station (GCS); 3) Ikhana UAS / Antennas; 4) Western States Fire Mission 2007 Partners; 5) FAA Certificate of Authorization (COA); 6) Western States Fire Missions (WSFM) 2007; 7) WSFM 1-4 2007; 8) California Wildfire Emergency Response 2007; 9) WSFM 5-8 Emergency Response 2007; 10) WSFM Achievements; and 11) WSFM Challenges.
NASA Technical Reports Server (NTRS)
Clements, Anna L.
2011-01-01
NASA is developing a Fine Water Mist Portable Fire Extinguisher for use on the International Space Station. The International Space Station presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segment, and a carbon dioxide extinguisher in the US Segment and Columbus and Kibo pressurized elements. Changes in emergency breathing equipment make Fine Water Mist operationally preferable. Supplied oxygen breathing systems allow for safe discharge of a carbon dioxide fire extinguisher, without concerns of the crew inhaling unsafe levels of carbon dioxide. But the Portable Breathing Apparatus (PBA) offers no more than 15 minutes of capability, and continued use of hose based supplied oxygen system increases the oxygen content in a fire situation. NASA has developed a filtering respirator cartridge for use in a fire environment. It is qualified to provide up to 90 minutes of capability, and because it is a filtering respirator it does not add oxygen to the environment. The fire response respirator cartridge does not filter carbon dioxide (CO2), so a crew member discharging a CO2 fire extinguisher while wearing this filtering respirator would be at risk of inhaling unsafe levels of CO2. Fine Water Mist extinguishes a fire without creating a large volume of air with reduced oxygen and elevated CO2. From a flight hardware design perspective, the fine water mist fire extinguisher has two major elements: (1) the nozzle and crew interface, and (2) the tank. The nozzle and crew interface has been under development for several years. It has gone through several design iterations, and has been part of more than 400 fire challenge and spray characterizations. The crew and vehicle interface aspects of the design will use the heritage of the CO2 based Portable Fire Extinguisher, to minimize the disruption to the crew and integration impacts to the ISS. The microgravity use environment of the system poses a set of unique design requirements specifically for the tank. The nozzle requirements drive a tank pressure that is 2-5 times higher than any commercially available water mist systems. Microgravity requires deliberate separation of gas and water, facilitated by a bladder, a diaphragm, a piston, or separate tanks. This paper will describe the design details of the tank and the nozzle, and discuss the trade studies that informed the decisions to select the tank and nozzle configuration.
Modeling Payload Stowage Impacts on Fire Risks On-Board the International Space Station
NASA Technical Reports Server (NTRS)
Anton, Kellie e.; Brown, Patrick F.
2010-01-01
The purpose of this presentation is to determine the risks of fire on-board the ISS due to non-standard stowage. ISS stowage is constantly being reexamined for optimality. Non-standard stowage involves stowing items outside of rack drawers, and fire risk is a key concern and is heavily mitigated. A Methodology is needed to account for fire risk due to non-standard stowage to capture the risk. The contents include: 1) Fire Risk Background; 2) General Assumptions; 3) Modeling Techniques; 4) Event Sequence Diagram (ESD); 5) Qualitative Fire Analysis; 6) Sample Qualitative Results for Fire Risk; 7) Qualitative Stowage Analysis; 8) Sample Qualitative Results for Non-Standard Stowage; and 9) Quantitative Analysis Basic Event Data.
Fire behavior and risk analysis in spacecraft
NASA Technical Reports Server (NTRS)
Friedman, Robert; Sacksteder, Kurt R.
1988-01-01
Practical risk management for present and future spacecraft, including space stations, involves the optimization of residual risks balanced by the spacecraft operational, technological, and economic limitations. Spacecraft fire safety is approached through three strategies, in order of risk: (1) control of fire-causing elements, through exclusion of flammable materials for example; (2) response to incipient fires through detection and alarm; and (3) recovery of normal conditions through extinguishment and cleanup. Present understanding of combustion in low gravity is that, compared to normal gravity behavior, fire hazards may be reduced by the absence of buoyant gas flows yet at the same time increased by ventilation flows and hot particle expulsion. This paper discusses the application of low-gravity combustion knowledge and appropriate aircraft analogies to fire detection, fire fighting, and fire-safety decisions for eventual fire-risk management and optimization in spacecraft.
NASA Technical Reports Server (NTRS)
Josephs, R. H.
1982-01-01
The design and performance of a modestly sized utility-connected power conditioning system and its supporting photovoltaic collector are described and estimated. Utility preparations and guidelines to conform with the output of a small generating station with that of a large power network are examined.
History of Fire and Fire Impacts at Tonto National Monument, Arizona
Phillips, Barbara G.
1997-01-01
A study of the history of fire and fire impacts on desert plants of Tonto National Monument was made in 1990-1991 by the author. Four major fires and several minor ones have occurred on the monument since 1942, all lightning caused. Twenty photo stations set up after the 1964 Schultz Fire were found and replicate photos made at the rebar-marked sites. Photographic documentation of the impacts of several fires made comparison of vegetation changes over time possible. Five monitoring plots were established in March and April 1990, representing a variety of vegetation associations in burned and unburned areas. An inventory of plants of the monument was completed in 1964 by Burgess (1965) prior to the first major fire. Comparisons of change across the 26-year span were made during this study. The effects of fire?in some areas multiple fires?were determined and reported on.
View of building 11050 looking northeast, showing metal sided and ...
View of building 11050 looking northeast, showing metal sided and roofed addition on east elevation. - Naval Ordnance Test Station Inyokern, China Lake Pilot Plant, Fire Station & Marine Barracks, D Street, at corner of 4th Street, China Lake, Kern County, CA
View of building 11050 looking northwest, with metal sided and ...
View of building 11050 looking northwest, with metal sided and roofed addition on east elevation. - Naval Ordnance Test Station Inyokern, China Lake Pilot Plant, Fire Station & Marine Barracks, D Street, at corner of 4th Street, China Lake, Kern County, CA
2012-06-27
ISS031-E-146306 (27 June 2012) --- An Expedition 31 crew member aboard the International Space Station, flying approximately 240 miles (386 kilometers) above Earth, captured this view of the Fontenelle fire on June 27, 2012. The fire, burning in Wyoming 18 miles (29 kilometers) west of Big Piney, was discovered on June 24. [Editor?s update --- By the morning of June 28, the fire had burned 25,000 acres (101 square kilometers). By July 6, the area burned had more than doubled to 57,324 acres (232 square kilometers), and the fire was 25 percent contained].
The report gives results of the full-scale demonstration of Limestone Injection Multistage Burner (LIMB) technology on the coal-fired, 105 MW, Unit 4 boiler at Ohio Edison's Edgewater Station. eveloped as a technology aimed at moderate levels of sulfur dioxide (SO2) and nitrogen ...
Characterizing fuels in the 21st century.
David Sandberg; Roger D. Ottmar; Geoffrey H. Cushon
2001-01-01
The ongoing development of sophisticated fire behavior and effects models has demonstrated the need for a comprehensive system of fuel classification that more accurately captures the structural complexity and geographic diversity of fuelbeds. The Fire and Environmental Research Applications Team (FERA) of the USD Forest Service, Pacific Northwest Research Station, is...
46 CFR 15.1105 - Familiarization and basic training (BT).
Code of Federal Regulations, 2014 CFR
2014-10-01
... onboard about elementary safety matters and understand informational symbols, signs, and alarm signals concerning safety; (ii) Knows what to do if a person falls overboard; if fire or smoke is detected; or if the fire alarm or abandon-ship alarm sounds; (iii) Can identify stations for muster and embarkation, and...
Forest research notes, Pacific Northwest Forest Experiment Station, No. 27, May 1, 1939.
Thornton T. Munger; Donald N. Matthews; Douglas C. Welch; Theodore Kachin; Loyd Bransford; Ernest L. Kolbe; Donald F. McKay; Leo A. Isaac
1939-01-01
Security from fire is the all-important prerequisite for timber growing after clear-cut logging in this region. Maximum security from fire is attained only when the land is again covered with a continuous cover of trees 20 to 30 or more years old.
Potential climate change impacts on fire weather in the United States
Warren E. Heilman; Ying Tang; Lifeng Luo; Shiyuan Zhong; Julie Winkler; Xindi. Bian
2015-01-01
Researchers at Michigan State University and the Forest Service's Northern Research Station worked on a joint study to examine the possible effects of future global and regional climate change on the occurrence of fire-weather patterns often associated with extreme and erratic wildfire behavior in the United States.
Shi, Jianwu; Deng, Hao; Bai, Zhipeng; Kong, Shaofei; Wang, Xiuyan; Hao, Jiming; Han, Xinyu; Ning, Ping
2015-05-15
107 kinds of C₂-C₁₂ volatile organic compound (VOC) mass concentrations and profiles for four types of coal-fired stationary sources in Liaoning Province were studied by a dilution sampling system and GC-MS analysis method, which are of significant importance with regard to VOC emissions in northeast of China. The results showed that there were some differences among these VOC source profiles. The total mass concentrations of analyzed 107 VOC species varied from 10,917 to 19,652 μg m(-3). Halogenated hydrocarbons exhibited higher mass percentages for the VOC source profiles of iron smelt (48.8%) and coke production plant (37.7%). Aromatic hydrocarbons were the most abundant in heating station plant (69.1%). Ketones, alcohols and acetates held 45.0% of total VOCs in thermal power plant. For non-methane hydrocarbons (NMHCs), which are demanded for photochemical assessment in the USA, toluene and n-hexane were the most abundant species in the iron smelt, coke production and thermal power plant, with the mass percentages of 64.8%, 52.7% and 38.6%, respectively. Trimethylbenzene, n-propylbenzene and o,m-ethyltoluene approximately accounted for 70.0% in heating station plant. NMHCs emitted from coke production, iron smelt, heating station and power plant listed above presented different chemical reactivities. The average OH loss rate of NMHCs from heating station, was 4 to 5.6 times higher than that of NMHCs from iron smelt, coke production and power plant, which implies that VOCs emitted from heating station in northeast of China should be controlled firstly to avoid photochemical ozone pollution and protect human health. There are significant variations in the ratios of benzene/toluene and m, p-xylene/ethylbenzene of these coal-fired source profiles. The representativeness of the coal-fired sources studied and the VOC samples collected should be more closely examined. The accuracy of VOC source profiles related to coal-fired processes is highly dependent on location and sampling method. Copyright © 2015 Elsevier B.V. All rights reserved.
Fire Safety Aspects of Polymeric Materials. Volume 4. Fire Dynamics and Scenarios
1978-01-01
Toxicology and In- dustrial Medicine, E. I. duPont de Nemours and Co., Newark Delaware ARNOLD ROSENTHAL, Celanese Research Company, Summit, New Jersey...Station, Atlantic City, N.J. PAUL W. SMITH, Aviation Toxicology Laboratory, Civil A^romedical Institute, Oklahoma City, Oklahoma ROBERT C. MCQUIRE, DoT...research. Table 1, based on estimates, is a representation of the total funding for fire dynamics research. (In Table 1, research on the toxicology
2014-09-11
Cape Canaveral, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, the 9/11 memorial is shown before a ceremony held by Kennedy’s Fire and Rescue personnel. Kennedy Fire and Rescue Services commemorated the 13th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Photo credit: Jim Grossmann
2014-09-11
Cape Canaveral, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, the 9/11 memorial emblem is shown during a ceremony held by Kennedy’s Fire and Rescue personnel. Kennedy Fire and Rescue Services commemorated the 13th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Photo credit: Jim Grossmann
Changes in contaminant loading and hydro-chemical storm behavior after the Station Fire
NASA Astrophysics Data System (ADS)
Burke, M. P.; Hogue, T. S.; Barco, J.; Wessel, C. J.
2010-12-01
The 2009 Station Fire, currently noted as the largest fire in Los Angeles County history, consumed over 650 square kilometers of National Forest land in the San Gabriel Mountain Range. These mountains, located on the east side (leeward) of the Los Angeles basin, are known to have some of the highest deposition rates of atmospheric pollutants in the nation. Even pre-fire, urban-fringe basins in this mountain range serve as an upstream source of contaminants to downstream urban streams. Burned watersheds undergo significant physical and chemical changes that dramatically alter hydrologic flowpaths, erosion potential, surface soil chemistry, and pollutant delivery. Much of the degradation in water quality is attributed to the extensive soil erosion during post-fire runoff events which carry large sediment loads, mobilizing and transporting contaminants to and within downstream waters. High resolution storm samples collected from a small front range watershed provide a unique opportunity to investigate the impacts of wildfire contaminant loading in a watershed that is significantly impacted by high atmospheric deposition of urban contaminates. Data includes four events from WY 2009 (pre-fire) and WY 2010 (post-fire), along with inter-storm grab samples from each storm season. Samples were analyzed for basic anions, nutrients, trace metals, and total suspended solids. Following the fire, storms with similar precipitation patterns yielded loads up to three orders of magnitude greater than pre-fire for some toxic metals, including lead and cadmium. Dramatic increases were also observed in trace metal concentrations typically associated with particulates, while weathering solute concentrations decreased. Post fire intra-storm dynamics exhibited a shift back toward pre-fire behavior by the end of the first rainy season for most of the measured constituents. Additionally, some unexpected behaviors were observed; specifically mercury loads continued to increase throughout the first post-fire rainy season regardless of storm size.
Characterization of fire regime in Sardinia (Italy)
NASA Astrophysics Data System (ADS)
Bacciu, V. M.; Salis, M.; Mastinu, S.; Masala, F.; Sirca, C.; Spano, D.
2012-12-01
In the last decades, a number of Authors highlighted the crucial role of forest fires within Mediterranean ecosystems, with impacts both negative and positive on all biosphere components and with reverberations on different scales. Fire determines the landscape structure and plant composition, but it is also the cause of enormous economic and ecological damages, beside the loss of human life. In Sardinia (Italy), the second largest island of the Mediterranean Basin, forest fires are perceived as one of the main environmental and social problems, and data are showing that the situation is worsening especially within the rural-urban peripheries and the increasing number of very large forest fires. The need for information concerning forest fire regime has been pointed out by several Authors (e.g. Rollins et al., 2002), who also emphasized the importance of understanding the factors (such as weather/climate, socio-economic, and land use) that determine spatial and temporal fire patterns. These would be used not only as a baseline to predict the climate change effect on forest fires, but also as a fire management and mitigation strategy. The main aim of this paper is, thus, to analyze the temporal and spatial patterns of fire occurrence in Sardinia (Italy) during the last three decades (1980-2010). For the analyzed period, fire statistics were provided by the Sardinian Forest Service (CFVA - Corpo Forestale e di Vigilanza Ambientale), while weather data for eight weather stations were obtained from the web site www.tutiempo.it. For each station, daily series of precipitation, mean, maximum and minimum temperature, relative humidity and wind speed were available. The present study firstly analyzed fire statistics (burned area and number of fires) according to the main fire regime characteristics (seasonality, fire return interval, fire incidence, fire size distribution). Then, fire and weather daily values were averaged to obtain monthly, seasonal and annual values, and a set of parametric and not parametric statistical tests were used to analyze the fire-weather relationships. Results showed a high inter- and intra-annual variability, also considering the different type of affected vegetation. As for other Mediterranean areas, a smaller number of large fires caused a high proportion of burned area. Land cover greatly influenced fire occurrence and fire size distribution across the landscape. Furthermore, fire activity (number of fires and area burned) showed significant correlations with weather variables, especially summer precipitation and wind, which seemed to drive the fire seasons and the fire propagation, respectively.
2000-09-14
KENNEDY SPACE CENTER, FLA. -- During training exercises at Cape Canaveral Air Force Station Pad 30, firefighters with the Fire and Emergency Services at the Naval Station Mayport, Fla., wait while the NASA/USAF water carrier truck directs its water cannon toward a burning simulated aircraft (out of view).
2000-09-14
KENNEDY SPACE CENTER, FLA. -- During training exercises at Cape Canaveral Air Force Station Pad 30, firefighters with the Fire and Emergency Services at the Naval Station Mayport, Fla., wait while the NASA/USAF water carrier truck directs its water cannon toward a burning simulated aircraft (out of view).
NASA Technical Reports Server (NTRS)
Priem, Richard J.
1988-01-01
The purpose of this study is to define the requirements of commercially motivated microgravity combustion experiments and the optimal way for space station to accommodate these requirements. Representatives of commercial organizations, universities and government agencies were contacted. Interest in and needs for microgravity combustion studies are identified for commercial/industrial groups involved in fire safety with terrestrial applications, fire safety with space applications, propulsion and power, industrial burners, or pollution control. From these interests and needs experiments involving: (1) no flow with solid or liquid fuels; (2) homogeneous mixtures of fuel and air; (3) low flow with solid or liquid fuels; (4) low flow with gaseous fuel; (5) high pressure combustion; and (6) special burner systems are described and space station resource requirements for each type of experiment provided. Critical technologies involving the creation of a laboratory environment and methods for combining experimental needs into one experiment in order to obtain effective use of space station are discussed. Diagnostic techniques for monitoring combustion process parameters are identified.
NASA Technical Reports Server (NTRS)
Clements, Anna L.; Carlile, Christie; Graf, John; Young, Gina
2011-01-01
NASA is developing a Fine Water Mist (FWM) Portable Fire Extinguisher (PFE) for use on the International Space Station. The International Space Station presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segment, and a carbon dioxide extinguisher in the US Segment and Columbus and Kibo pressurized elements. Changes in emergency breathing equipment make Fine Water Mist operationally preferable. Supplied oxygen breathing systems allow for safe discharge of a carbon dioxide fire extinguisher, without concerns of the crew inhaling unsafe levels of carbon dioxide. But the Portable Breathing Apparatus (PBA) offers no more than 15 minutes of capability, and continued use of hose based supplied oxygen system increases the oxygen content in a fire situation. NASA has developed a filtering respirator cartridge for use in a fire environment. It is qualified to provide up to 90 minutes of capability, and because it is a filtering respirator it does not add oxygen to the environment. The fire response respirator cartridge does not filter carbon dioxide (CO2), so a crew member discharging a CO2 fire extinguisher while wearing this filtering respirator would be at risk of inhaling unsafe levels of CO2. FWM extinguishes a fire without creating a large volume of air with reduced oxygen and elevated CO2. The following paper will discuss the unique functional and performance requirements that have been levied on the FWM PFE. In addition, the NASA ISS specific fire standards will be described which were developed to establish acceptable extinguisher performance. The paper will also discuss the flight hardware design. The fin e water mist fire extinguisher has two major elements: (1) the nozzle and crew interface, and (2) the tank. The nozzle and crew interface have been under development for several years. They have gone through several design iterations, and have been part of more than 400 fire challenge and spray characterizations. The crew and vehicle interface aspects of the design will use the heritage of the CO2 based Portable Fire Extinguisher, to minimize the disruption to the crew and integration impacts to the ISS. The microgravity use environment of the system poses a set of unique design requirements specifically for the tank. The nozzle requirements drive a tank pressure that is 2-5 times higher than any commercially available water mist systems. Microgravity requires deliberate separation of gas and water, facilitated by a bladder, a diaphragm, a piston, or separate tanks. This paper will describe status of the project to date, the design details of the tank and the nozzle, and discuss the trade studies that informed the decisions to select the tank and nozzle configuration.
Emergency Response Fire-Imaging UAS Missions over the Southern California Wildfire Disaster
NASA Technical Reports Server (NTRS)
DelFrate, John H.
2008-01-01
Objectives include: Demonstrate capabilities of UAS to overfly and collect sensor data on widespread fires throughout Western US. Demonstrate long-endurance mission capabilities (20-hours+). Image multiple fires (greater than 4 fires per mission), to showcase extendable mission configuration and ability to either linger over key fires or station over disparate regional fires. Demonstrate new UAV-compatible, autonomous sensor for improved thermal characterization of fires. Provide automated, on-board, terrain and geo-rectified sensor imagery over OTH satcom links to national fire personnel and Incident commanders. Deliver real-time imagery (within 10-minutes of acquisition). Demonstrate capabilities of OTS technologies (GoogleEarth) to serve and display mission-critical sensor data, coincident with other pertinent data elements to facilitate information processing (WX data, ground asset data, other satellite data, R/T video, flight track info, etc).
Emergency Response Fire-Imaging UAS Missions over the Southern California Wildfire Disaster
NASA Technical Reports Server (NTRS)
Cobleigh, Brent R.
2007-01-01
Objectives include: Demonstrate capabilities of UAS to overfly and collect sensor data on widespread fires throughout Western US. Demonstrate long-endurance mission capabilities (20-hours+). Image multiple fires (greater than 4 fires per mission), to showcase extendable mission configuration and ability to either linger over key fires or station over disparate regional fires. Demonstrate new UAV-compatible, autonomous sensor for improved thermal characterization of fires. Provide automated, on-board, terrain and geo-rectified sensor imagery over OTH satcom links to national fire personnel and Incident commanders. Deliver real-time imagery (within 10-minutes of acquisition). Demonstrate capabilities of OTS technologies (GoogleEarth) to serve and display mission-critical sensor data, coincident with other pertinent data elements to facilitate information processing (WX data, ground asset data, other satellite data, R/T video, flight track info, etc).
Heavy metals in Parmelia sulcata collected in the neighborhood of a coal-fired power station.
Freitas, M C
1994-01-01
The epiphytic lichen Parmelia sulcata was collected in the neighborhood of a Portuguese coal-fired power station (Sines coal power station) as monitor for heavy metal air pollution. A study of the metal contents variability along 1991 and 1992 was performed. The heavy metals Ag, As, Br, Co, Cr, Fe, Hg, Sb, Se, and Zn were determined by k0-based instrumental neutron activation analysis. The concentrations found in 1991 and 1992 show an accumulating process of Co and Fe (approximately 5%/mo) and of Cr and Sb (approximately 7%/mo). Low accumulation is observed for Ag, Se, and Zn (approximately 2%/mo), and no concentration variation is observed for As, Br, and Hg. It is concluded that the metal accumulation observed is the result of the nearby ash and coal deposits.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-26
... (NO X ) for Milton R. Young Station Units 1 and 2 and Leland Olds Station Unit 2, which are coal-fired... approval of North Dakota's BART emission limits for NO X for Milton R. Young Station Units 1 and 2 and... appropriate. The limitation is to ensure that everyone who wants to make comments has the opportunity to do so...
Rodeo and Chediski Fires in Arizona
NASA Technical Reports Server (NTRS)
2002-01-01
Over the weekend, the Rodeo and Chediski Fires in Arizona grew explosively, and the two large fires are now beginning to merge. Smoke from the fires is stretching hundreds of kilometers northeast, where it may be mingling with smoke from the Missionary Ridge Fire in Colorado. The Rodeo Fire is now 205,000 acres, and the Chediski is over 100,000. More than 200 structures have been lost in the two blazes, but many more hundreds have been saved by firefighters. This Moderate Resolution Imaging Spectroradiometer (MODIS) image was acquired Sunday, June 23, 2002. The data were collected via MODIS? Direct Broadcast capability, in which real time data are continuously broadcast, and can be received by ground stations directly in the path of the Terra satellite.
Earth Observations taken by the Expedition 15 Crew
2007-08-13
ISS015-E-22274 (13 Aug. 2007) --- Smoke plumes from a forest fire in the Gallatin National Forest, Montana is featured in this image photographed by an Expedition 15 crewmember on the International Space Station while Space Shuttle Endeavour (STS-118) was docked with the station.
SOUTH FIRE HOUSE, ELEVATIONS AND DETAILS, BUILDING NO. 726. Navy ...
SOUTH FIRE HOUSE, ELEVATIONS AND DETAILS, BUILDING NO. 726. Navy Yard, Mare Island, CA. Y & D (Yards and Docks) drawing no. 282851, approved October 23, 194_ (year not given); file no. 726-CR-2; stamped "Record drawing to accompany technical report on contract no. 4550, project no. 16." Various scales. 71 cm x 86 cm. Ink on vellum. - Mare Island Naval Shipyard, South Fire Station, Railroad Avenue near Eighteenth Street, Vallejo, Solano County, CA
D.J. Kitchen; J.M. Blair; M.A. Callaham
2009-01-01
Management practices, such as fire andmowing, can affect the distribution and quality of roots and soil C and N in grasslands. We examined long-term (13 years) effects of annual fire and mowing on fine (<2 mm) roots and soil C and N content in a native tallgrass prairie at Konza Prairie Biological Station in northeastern Kansas, USA. Using 90 cm deep soil cores...
2017-11-01
From left, Col. Z. Walter Jackim, vice commander, 45th Space Wing, Cape Canaveral Air Force Station; Michael Good, assistant fire management officer, Merritt Island National Wildlife Refuge; John Fish, chief, Florida Forest Service; Mark Schollmeyer, chief, Brevard County Fire Rescue; and Kelvin Manning, associate director, NASA's Kennedy Space Center, pose for a portrait following a ceremony Nov. 1 on the Merritt Island National Wildlife Refuge in Florida. During the joint ceremony, the Spaceport Integration Team and its partners were presented with the prestigious 2017 Pulaski Award and a new memorial marker was dedicated. The multi-agency team includes representatives from NASA's Kennedy Space Center, Cape Canaveral Air Force Station's 45th Space Wing, the Merritt Island National Wildlife Refuge, as well as the Florida Forest Service and Brevard County Fire Rescue. The memorial marker honors two fallen firefighters, Scott Maness and Beau Sauselein, who died fighting a wildfire on space center property in 1981. Held outdoors, the ceremony was attended by 140 guests.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-04-01
The proposed Penelec project is one of 5 projects for potential funding under the fifth solicitation under the Clean Coal Technology program. In Penelec, two existing boilers would be replaced at Warren Station, PA; the new unit would produce 73 MW(e) in a combined cycle mode (using both gas-fired and steam turbines). The project would fill the need for a full utility-size demonstration of externally fire combined cycle (EFCC) technology as the next step toward commercialization. This environmental assessment was prepared for compliance with NEPA; its purpose is to provide sufficient basis for determining whether to prepare an environmental impactmore » statement or to issue a finding of no significant impact. It is divided into the sections: purpose and need for proposed action; alternatives; brief description of affected environment; environmental consequences, including discussion of commercial operation beyond the demonstration period.« less
Family and Nation: Cherokee Orphan Care, 1835-1903
ERIC Educational Resources Information Center
Reed, Julie L.
2010-01-01
On November 17, 1903, fifteen miles from the nearest railway station and fifty miles northwest of the capital of the Cherokee Nation in Tahlequah, a fire engulfed the Cherokee Orphan Asylum. After the fire the Cherokee Nation relocated the homeless children to the nation's Insane Asylum in Tahlequah, where Sequoyah School stands today. The…
This report summarizes the effects of a coal-fired power plant on terrestrial plants and animals. Research was conducted from 1971 through 1977 at the Columbia Generating Station in the eastern flood-plain of the Wisconsin River in south-central Wisconsin. Initial studies were la...
Cornerstones: Building Rural America through Service Learning.
ERIC Educational Resources Information Center
Pace, Jerry
Students in a poor, rural county in South Carolina worked with their community to build a new volunteer fire station, enabling many residents to get fire insurance. The project enabled students to see the relevance of education and to be seen as solutions to problems rather than as problems, generated enthusiasm among students toward the community…
Earth observations taken by the Expedition Seven crew
2003-08-02
ISS007-E-11613 (2 August 2003) --- This digital still camera's view from the International Space Station features early August forest fires in the Lost Creek area on the border of Alberta and British Columbia, just to the southwest of Calgary. Across the international border, fires were raging in the Glacier National Park in Montana
Earth observations taken by the Expedition Seven crew
2003-08-02
ISS007-E-11614 (2 August 2003) --- This digital still camera's view from the International Space Station features early August forest fires in the Lost Creek area on the border of Alberta and British Columbia, just to the southwest of Calgary. Across the international border, fires were raging in the Glacier National Park in Montana
46 CFR 28.830 - Fire detection system.
Code of Federal Regulations, 2011 CFR
2011-10-01
... must be equipped with an independent modular smoke detector or a smoke actuated fire detecting unit installed in accordance with § 76.33 of this chapter. (b) An independent modular smoke detector must meet UL 217 and be listed as a “Single Station Smoke Detector—Also Suitable for Use in Recreational Vehicles”. ...
46 CFR 28.830 - Fire detection system.
Code of Federal Regulations, 2013 CFR
2013-10-01
... must be equipped with an independent modular smoke detector or a smoke actuated fire detecting unit installed in accordance with § 76.33 of this chapter. (b) An independent modular smoke detector must meet UL 217 and be listed as a “Single Station Smoke Detector—Also Suitable for Use in Recreational Vehicles”. ...
46 CFR 28.830 - Fire detection system.
Code of Federal Regulations, 2010 CFR
2010-10-01
... must be equipped with an independent modular smoke detector or a smoke actuated fire detecting unit installed in accordance with § 76.33 of this chapter. (b) An independent modular smoke detector must meet UL 217 and be listed as a “Single Station Smoke Detector—Also Suitable for Use in Recreational Vehicles”. ...
46 CFR 28.830 - Fire detection system.
Code of Federal Regulations, 2012 CFR
2012-10-01
... must be equipped with an independent modular smoke detector or a smoke actuated fire detecting unit installed in accordance with § 76.33 of this chapter. (b) An independent modular smoke detector must meet UL 217 and be listed as a “Single Station Smoke Detector—Also Suitable for Use in Recreational Vehicles”. ...
46 CFR 28.830 - Fire detection system.
Code of Federal Regulations, 2014 CFR
2014-10-01
... must be equipped with an independent modular smoke detector or a smoke actuated fire detecting unit installed in accordance with § 76.33 of this chapter. (b) An independent modular smoke detector must meet UL 217 and be listed as a “Single Station Smoke Detector—Also Suitable for Use in Recreational Vehicles”. ...
Real time forest fire warning and forest fire risk zoning: a Vietnamese case study
NASA Astrophysics Data System (ADS)
Chu, T.; Pham, D.; Phung, T.; Ha, A.; Paschke, M.
2016-12-01
Forest fire occurs seriously in Vietnam and has been considered as one of the major causes of forest lost and degradation. Several studies of forest fire risk warning were conducted using Modified Nesterov Index (MNI) but remaining shortcomings and inaccurate predictions that needs to be urgently improved. In our study, several important topographic and social factors such as aspect, slope, elevation, distance to residential areas and road system were considered as "permanent" factors while meteorological data were updated hourly using near-real-time (NRT) remotely sensed data (i.e. MODIS Terra/Aqua and TRMM) for the prediction and warning of fire. Due to the limited number of weather stations in Vietnam, data from all active stations (i.e. 178) were used with the satellite data to calibrate and upscale meteorological variables. These data with finer resolution were then used to generate MNI. The only significant "permanent" factors were selected as input variables based on the correlation coefficients that computed from multi-variable regression among true fire-burning (collected from 1/2007) and its spatial characteristics. These coefficients also used to suggest appropriate weight for computing forest fire risk (FR) model. Forest fire risk model was calculated from the MNI and the selected factors using fuzzy regression models (FRMs) and GIS based multi-criteria analysis. By this approach, the FR was slightly modified from MNI by the integrated use of various factors in our fire warning and prediction model. Multifactor-based maps of forest fire risk zone were generated from classifying FR into three potential danger levels. Fire risk maps were displayed using webgis technology that is easy for managing data and extracting reports. Reported fire-burnings thereafter have been used as true values for validating the forest fire risk. Fire probability has strong relationship with potential danger levels (varied from 5.3% to 53.8%) indicating that the higher potential risk, the more chance of fire happen. By adding spatial factors to continuous daily updated remote sensing based meteo-data, results are valuable for both mapping forest fire risk zones in short and long-term and real time fire warning in Vietnam. Key words: Near-real-time, forest fire warning, fuzzy regression model, remote sensing.
NASA Technical Reports Server (NTRS)
1982-01-01
The ventilation and fire safety requirements for subway tunnels with dipped profiles between stations as compared to subway tunnels with level profiles were evaluated. This evaluation is based upon computer simulations of a train fire emergency condition. Each of the tunnel configurations evaluated was developed from characteristics that are representative of modern transit systems. The results of the study indicate that: (1) The level tunnel system required about 10% more station cooling than dipped tunnel systems in order to meet design requirements; and (2) The emergency ventilation requirements are greater with dipped tunnel systems than with level tunnel systems.
Earth Observations taken by the Expedition 13 crew
2006-09-17
ISS013-E-81687 (17 Sept. 2006) --- A forest fire in southern California is featured in this image photographed by an Expedition 13 crewmember on the International Space Station. The day fire started in Los Padres National Forest north of Los Angeles on Sept. 4, 2006. Easterly winds on Sept. 17 blew the smoke west out to sea, and this wind shift was observed by station crewmembers. The forested mountains north of Los Angeles appear dark green, the smoke a dusky gray. Dense farmland at the south end of California's central valley is framed by the forested Sierra Nevada mountain range. White patches near the center of the view are dry lakes of the Mojave Desert, one of which acts as a landing site for the space shuttle. The dark irregular shape at image right is part of the space station. Death Valley and Las Vegas are visible at image right. The extent of the day fire smoke plume can be gauged from the gray urban region of greater Los Angeles (center) which stretches along 50 miles of coastline. The plume obscures the northern Channel Islands, but the southern Channel Islands are silhouetted against the ocean.
2014-09-11
Cape Canaveral, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, Kennedy Space Center Fire Chief Richard Anderson, center and Commander of the Honor Guard James Dumont, left, share emotional words at the 9/11 memorial during a ceremony held by Kennedy’s Fire and Rescue personnel. Behind the pair are members of NASA's Protective Services. Kennedy Fire and Rescue Services commemorated the 13th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Photo credit: Jim Grossmann
Method of locating underground mines fires
Laage, Linneas; Pomroy, William
1992-01-01
An improved method of locating an underground mine fire by comparing the pattern of measured combustion product arrival times at detector locations with a real time computer-generated array of simulated patterns. A number of electronic fire detection devices are linked thru telemetry to a control station on the surface. The mine's ventilation is modeled on a digital computer using network analysis software. The time reguired to locate a fire consists of the time required to model the mines' ventilation, generate the arrival time array, scan the array, and to match measured arrival time patterns to the simulated patterns.
2012-09-11
CAPE CANAVERAL, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, Fire and Rescue personnel salute or stand at attention during the 9/11 memorial dedication ceremony. Kennedy Fire and Rescue Services commemorated the 11th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Kennedy center-wide emergency units dispatched by Fire Control engaged in one-minute sirens, the new memorial was dedicated and the Honor Guard performed a flag-folding ceremony. Photo credit: NASA/Dimitri Gerondidakis
2012-09-11
CAPE CANAVERAL, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, Fire and Rescue personnel pause for a moment of silence during the 9/11 memorial dedication ceremony. Kennedy Fire and Rescue Services commemorated the 11th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Kennedy center-wide emergency units dispatched by Fire Control engaged in one-minute sirens, the new memorial was dedicated and the Honor Guard performed a flag-folding ceremony. Photo credit: NASA/Dimitri Gerondidakis
2012-09-11
CAPE CANAVERAL, Fla. – NASA Kennedy Space Center’s Fire and Rescue personnel stand at attention during a 9/11 memorial dedication ceremony in front of Fire Station 1 at Kennedy in Florida. Kennedy Fire and Rescue Services commemorated the 11th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Kennedy center-wide emergency units dispatched by Fire Control engaged in one-minute sirens, the new memorial was dedicated and the Honor Guard performed a flag-folding ceremony. Photo credit: NASA/Dimitri Gerondidakis
2012-09-11
CAPE CANAVERAL, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, Fire and Rescue personnel gathered near the new 9/11 memorial after the dedication ceremony. Kennedy Fire and Rescue Services commemorated the 11th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Kennedy center-wide emergency units dispatched by Fire Control engaged in one-minute sirens, the new memorial was dedicated and the Honor Guard performed a flag-folding ceremony. Photo credit: NASA/Dimitri Gerondidakis
2012-09-11
CAPE CANAVERAL, Fla. – NASA Kennedy Space Center’s Fire and Rescue personnel stand at attention during a 9/11 memorial dedication ceremony in front of Fire Station 1 at Kennedy in Florida. Kennedy Fire and Rescue Services commemorated the 11th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Kennedy center-wide emergency units dispatched by Fire Control engaged in one-minute sirens, the new memorial was dedicated and the Honor Guard performed a flag-folding ceremony. Photo credit: NASA/Dimitri Gerondidakis
2012-09-11
CAPE CANAVERAL, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, Fire and Rescue personnel salute during the 9/11 memorial dedication ceremony. Kennedy Fire and Rescue Services commemorated the 11th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Kennedy center-wide emergency units dispatched by Fire Control engaged in one-minute sirens, the new memorial was dedicated and the Honor Guard performed a flag-folding ceremony. Photo credit: NASA/Dimitri Gerondidakis
77 FR 26543 - UGI Storage Company; Notice of Request Under Blanket Authorization
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-04
... approximately 3,450 horsepower (hp) of gas fired compression at its existing Palmer Station in Tioga County... compressor units and one 690 hp unit at the Palmer Station located at the downstream terminus of the TL-94...-3-12; 8:45 am] BILLING CODE 6717-01-P ...
46 CFR 190.07-10 - Construction.
Code of Federal Regulations, 2010 CFR
2010-10-01
... use of other suitable material in special cases, having in mind the risk of fire. (b) The boundary... bulkheads and decks separating the accomodations and control stations from hold and machinery spaces... square feet or less from accommodations and control stations shall be of “A-15” Class construction as...
2000-09-14
KENNEDY SPACE CENTER, FLA. -- Firefighters hold their hoses on a burning simulated aircraft, creating a rainbow. Watching at right (red uniform) and in the foreground are trainers. The training exercises for firefighters with Fire and Emergency Services at Naval Station Mayport, Fla., are being held at Cape Canaveral Air Force Station Pad 30.
2000-09-14
KENNEDY SPACE CENTER, FLA. -- Firefighters hold their hoses on a burning simulated aircraft, creating a rainbow. Watching at right (red uniform) and in the foreground are trainers. The training exercises for firefighters with Fire and Emergency Services at Naval Station Mayport, Fla., are being held at Cape Canaveral Air Force Station Pad 30.
SOUTH FIRE HOUSE, PLANS AND DETAILS, BUILDING NO. 726 (Also ...
SOUTH FIRE HOUSE, PLANS AND DETAILS, BUILDING NO. 726 (Also includes a plot plan). Navy Yard, Mare Island, CA. Y & D (Yards and Docks) drawing no. 282850, approved October 23, 194_ (year not given); file no. 726-CR-1; stamped "Record drawing to accompany technical report on contract no. 4550, project no. 16." Various scales. 71 cm x 86 cm. Ink on vellum. - Mare Island Naval Shipyard, South Fire Station, Railroad Avenue near Eighteenth Street, Vallejo, Solano County, CA
SOUTH FIRE HOUSE, FIRST FLOOR FRAMING AND DETAILS, BUILDING NO. ...
SOUTH FIRE HOUSE, FIRST FLOOR FRAMING AND DETAILS, BUILDING NO. 726 (Also includes a foundation plan). Navy Yard, Mare Island, CA. Y & D (Yards & Docks) drawing no. 282852, approved October 22, 194_ (year not given); file no. 726-S-1; stamped "Record drawing to accompany technical report on contract no. 4550, project no. 16." Various scales. 71 cm x 86 cm. Ink on vellum. - Mare Island Naval Shipyard, South Fire Station, Railroad Avenue near Eighteenth Street, Vallejo, Solano County, CA
2010-11-10
Fire and steam signal a successful test firing of Orbital Sciences Corporation's Aerojet AJ26 rocket engine at John C. Stennis Space Center. AJ26 engines will be used to power Orbital's Taurus II space vehicle on commercial cargo flights to the International Space Station. On Nov. 10, operators at Stennis' E-1 Test Stand conducted a 10-second test fire of the engine, the first of a series of three verification tests. Orbital has partnered with NASA to provide eight missions to the ISS by 2015.
NASA Technical Reports Server (NTRS)
Kaszubowski, M.; Raney, J. P.
1986-01-01
A study was conducted to determine the dynamic effects of firing the orbiter primary reaction control jets during assembly of protoflight space station structure. Maximum longeron compressive load was calculated as a function of jet pulse time length, number of jet pulses, and total torque imposed by the reaction control jets. The study shows that it is possible to fire selected jets to achieve a pitch maneuver without causing failure of the attached structure.
2014-09-11
Cape Canaveral, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, Gabe Wingard and Steve Dudgeon, both with NASA's Protective Services, fold the commemorative flag during a ceremony held by Kennedy’s Fire and Rescue personnel. Kennedy Fire and Rescue Services commemorated the 13th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Photo credit: Jim Grossmann
1. Credit USAF, ca. 1942. Original housed in the Muroc ...
1. Credit USAF, ca. 1942. Original housed in the Muroc Flight Test Base, Unit History, 1 September 1942 - 30 June 1945. Alfred F. Simpson Historical Research Agency. United States Air Force. Maxwell AFB, Alabama. Historical view looks west southwest at construction of Building 4317, Deluge Water Pumping Station (then designated Pump House No. 3). This in-ground structure houses fire pumps which draw water from an in-ground reservoir, Building 4316 (See HAER photos CA-170-I). Pumping station was built in-ground to take advantage of gravity, since water flows from reservoir to prime the pumps, and fire system piping is underground. Opening in far wall is to stairs leading up to ground level. Earth mound in background is part of water reservoir construction (Building 4316). - Edwards Air Force Base, North Base, Deluge Water Pumping Station, Near Second & D Streets, Boron, Kern County, CA
NASA Technical Reports Server (NTRS)
Williams, David E.
2011-01-01
The International Space Station (ISS) Node 1 Environmental Control and Life Support (ECLS) System is comprised of five subsystems: Atmosphere Control and Storage (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). This paper will provide a summary of the Node 1 ECLS THC subsystem design and a detailed discussion of the ISS ECLS Acceptance Testing methodology utilized for this subsystem.The International Space Station (ISS) Node 1 Environmental Control and Life Support (ECLS) System is comprised of five subsystems: Atmosphere Control and Storage (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). This paper will provide a summary of the Node 1 ECLS THC subsystem design and a detailed discussion of the ISS ECLS Acceptance Testing methodology utilized for this subsystem.
Accomplishments of the American-Polish program for elimination of low emissions in Krakow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Butcher, T.A.; Pierce, B.
1998-12-31
Since 1990 the US Department of Energy (DOE) has been involved in a program aimed at reducing air pollution caused by small, coal-fired sources in Poland. The activity is focused on the city of Cracow, Poland with the intention that results will be applicable and extendable to the entire region. The effort under this program has been focused into 5 main areas of interest as follows: (1) energy conservation and extension of central station district heating; (2) replacement of coal- and coke-fired boilers with natural gas-fired boilers; (3) replacement of coal-fired home stoves with electric heating appliances; (4) reduction ofmore » emissions from stoker-fired boiler houses; and (5) reduction of emissions from coal-fired home heating stoves.« less
Scale Modeling for the PATRIOT Electromagnetic Pulse Test.
1981-05-01
concerned with providing basic in- formation that is either too costly and time consuming or impossible to obtain in a full-scale field operation. This...tar:je’.s.l The missiles are mounted on launching stations that are .4,t pfys;ically w.,nnected to the fire control section kFCS ). Fire contxoi vs mirnt
Measuring fire weather and forest inflammability
H. T. Gisborne
1936-01-01
In the measurement of fire weather and forest inflammability, now practiced regularly at more than 90 forest stations in northern Idaho and western Montana, it is necessary to use many methods that are peculiar to this work. Some of these methods are familiar to meteorologists, but few foresters have had any appreciable training in meteorology. Others are of such,...
Managing wildfire risk in fire-prone landscapes: how are private landowners contributing?
Joan O’Callaghan; A. Paige Fischer; Susan Charnley
2013-01-01
The fire-prone landscapes of the West include both public and private lands. Wildfire burns indiscriminately across property boundaries, which means that the way potential fuels are managed on one piece of property can affect wildfire risk on neighboring lands. Paige Fischer and Susan Charnley, social scientists with the Pacific Northwest Research Station, surveyed...
46 CFR 34.10-10 - Fire station hydrants, hose and nozzles-T/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
... must be located to afford protection from heavy seas. The hose must be stored in a location that is... metal. Couplings shall either: (1) Use National Standard fire hose coupling threads for the 11/2 inch... shall be connected to outlets at all times. However, in heavy weather on open decks where no protection...
Fanning the flames: climate change stacks odds against fire suppression.
Jonathan Thompson
2005-01-01
There is little question that global warming would increase the risk of wildfires by drying out vegetation and stirring the winds that spread fire. Until recently, however, land managers were unable to formulate appropriate responses because the spatial scales of predictions were far too coarse. Current research being done at the PNW Research Station in Portland,...
Where and when to measure forest fire danger
G. Lloyd. Hayes
1944-01-01
This article presents the results of a study to determine the place, time, and number of measurements that should be made to obtain dependable ratings of "average-bad" fire conditions without an excessive number of stations or observations. The author concludes that under the conditions prevailing in the Priest River Experimental Forest in northern Idaho a...
The principles of measuring forest fire danger
H. T. Gisborne
1936-01-01
Research in fire danger measurement was commenced in 1922 at the Northern Rocky Mountain Forest and Range Experiment Station of the U. S. Forest Service, with headquarters at Missoula, Mont. Since then investigations have been made concerning ( 1) what to measure, (2) how to measure, and ( 3) field use of these measurements. In all cases the laboratory or restricted...
Earth observations taken by the Expedition Seven crew
2003-08-02
ISS007-E-11609 (2 August 2003) --- This digital still camera's view from the International Space Station features early August forest fires in the Lost Creek area on the border of Alberta and British Columbia, just to the southwest of Calgary. Across the international border, the fires were raging in the Glacier National Park in Montana
2015-09-11
The honor guard for the Fire Department at NASA's Kennedy Space Center conducts the dedication service for a memorial to the 343 first responder victims of the Sept. 11, 2001, terror attacks at Fire Station 1 at Kennedy on Sept. 11, 2015. The ceremony dedicated a monument that includes a section of steel I-beam from the World Trade Center in New York.
2015-09-11
The Brevard Police and Fire Pipe and Drum corps open the dedication service for a memorial to the 343 first responder victims of the Sept. 11, 2001, terror attacks at Fire Station 1 at NASA's Kennedy Space Center on Sept. 11, 2015. The ceremony dedicated a monument that includes a section of steel I-beam from the World Trade Center in New York.
2015-09-11
The Brevard Police and Fire Pipe and Drum corps perform during the dedication service for a memorial to the 343 first responder victims of the Sept. 11, 2001, terror attacks at Fire Station 1 at NASA's Kennedy Space Center on Sept. 11, 2015. The ceremony dedicated a monument that includes a section of steel I-beam from the World Trade Center in New York.
2014-09-11
Cape Canaveral, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, Fire and Rescue personnel pause for a moment of silence during a ceremony commemorating the 13th anniversary of 9/11 at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Photo credit: Jim Grossmann
2014-09-11
Cape Canaveral, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, Fire and Rescue personnel pause for a moment of silence during a ceremony commemorating the 13th anniversary of 9/11 at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Photo credit: Jim Grossmann
H2FIRST Reference Station Design Task: Project Deliverable 2-2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pratt, Joseph; Terlip, Danny; Ainscough, Chris
2015-04-20
This report presents near-term station cost results and discusses cost trends of different station types. It compares various vehicle rollout scenarios and projects realistic near-term station utilization values using the station infrastructure rollout in California as an example. It describes near-term market demands and matches those to cost-effective station concepts. Finally, the report contains detailed designs for five selected stations, which include piping and instrumentation diagrams, bills of materials, and several site-specific layout studies that incorporate the setbacks required by NFPA 2, the National Fire Protection Association Hydrogen Technologies Code. This work identified those setbacks as a significant factor affectingmore » the ability to site a hydrogen station, particularly liquid stations at existing gasoline stations. For all station types, utilization has a large influence on the financial viability of the station.« less
NASA 2007 Western States Fire Missions (WSFM)
NASA Technical Reports Server (NTRS)
Buoni, Greg
2008-01-01
This viewgraph presentation describes the Western states Fire Missions (WSFM) that occurred in 2007. The objectives of this mission are: (1) Demonstrate capabilities of UAS to overfly and collect sensor data on widespread fires throughout Western US. (1) Demonstrate long-endurance mission capabilities (20-hours+). (2) Image multiple fires (greater than 4 fires per mission), to showcase extendable mission configuration and ability to either linger over key fires or station over disparate regional fires. (3) Demonstrate new UAV-compatible, autonomous sensor for improved thermal characterization of fires. (4) Provide automated, on-board, terrain and geo-rectified sensor imagery over OTH satcom links to national fire personnel and Incident commanders. (5) Deliver real-time imagery to (within 10-minutes of acquisition). (6) Demonstrate capabilities of OTS technologies (GoogleEarth) to serve and display mission-critical sensor data, coincident with other pertinent data elements to facilitate information processing (WX data, ground asset data, other satellite data, R/T video, flight track info, etc).
Use of intumescent compounds in fire curtains
NASA Astrophysics Data System (ADS)
Nedryshkin, Oleg; Gravit, Marina; Mukhamedzhanova, Olga
2017-10-01
Automatic fire curtains are designed to divide sections of premises and structures into fire compartments for the purpose of localizing a fire, as well as filling openings in fire barriers. If a fire occurs due to a signal from a fire alarm sensor or a signal from a fire station, the blind automatically falls and locates the source of ignition. The paper presents the results of testing nine samples of fire curtains with an applied intumescent composition. Tests were conducted for 60 minutes before loss of sample integrity. The average temperature from the heated side of the sample reached 800 ∼ 1000 ° C. Depending on the sample, the temperature from the unheated side ranged from 70 ° C to 294 ° C. The best result was shown by a sample from a layer of needle-punched heat-insulating material with a thermal conductivity of 0.036 W/(m×K) placed between layers of foil and treated with water-based intumescent composition of silica material.
20. HANGAR BAY #2 FORWARD LOOKING AFT ON CENTERLINE ...
20. HANGAR BAY #2 - FORWARD LOOKING AFT ON CENTERLINE - STARBOARD SIDE SHOWING CONFLAGRATION STATION, UPTAKE SPACE AND DEHUMIDIFICATION MACHINES - PORT SIDE SHOWING VARIOUS DECK WINCHES, ROLLER DOORS, HANGAR DECK PLANE CONTROL STATION AND AQUEOUS FIRE FIGHTING FOAM HOSE REELS. - U.S.S. HORNET, Puget Sound Naval Shipyard, Sinclair Inlet, Bremerton, Kitsap County, WA
Wiseman working with BASS-II Experiment
2014-06-26
ISS040-E-021546 (26 June 2014) --- NASA astronaut Reid Wiseman, Expedition 40 flight engineer, conducts a combustion experiment known as the Burning and Suppression of Solids (BASS) inside the Microgravity Science Glovebox (MSG) located in the International Space Station?s Destiny laboratory. Without gravity, materials burn quite differently, with a spherical flame instead of the conical shape seen on Earth. BASS is studying the hypothesis that some materials may actually become more flammable in space. Results from BASS will help guide spacecraft materials selection and improve strategies for putting out accidental fires aboard spacecraft. The research also provides scientists with improved computational models that will aid in the design of fire detection and suppression systems here on Earth.
NASA Astrophysics Data System (ADS)
Ryabov, G. A.; Folomeev, O. M.; Litun, D. S.; Sankin, D. A.; Dmitryukova, I. G.
2009-01-01
The present state and development of circulating fluidized bed (CFB) technology around the world are briefly reviewed. Questions of increasing the capacity of single boiler units and raising the parameters of steam are discussed. CFB boilers for 225- and 330-MW power units are described and their parameters are estimated as applied to the conditions of firing different Russian fuels. Indicators characterizing CFB boilers and pulverized-coal boilers are given. Capital outlays and operational costs for new coal-fired units are compared, and the results from this comparison are used to show the field of the most promising use of the CFB technology during technical refitting of Russian thermal power stations.
Developing Standards to Qualify a Fine Water Mist Fire Extinguisher for Human Spaceflight
NASA Technical Reports Server (NTRS)
Graf, John
2011-01-01
NASA is developing a Fine Water Mist Portable Fire Extinguisher for use on the International Space Station. The International Space Station presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segment, and a carbon dioxide extinguisher in the US Segment and Columbus and Kibo pressurized elements. Changes in emergency breathing equipment make Fine Water Mist operationally preferable. Supplied oxygen breathing systems allow for safe discharge of a carbon dioxide fire extinguisher, without concerns of the crew inhaling unsafe levels of carbon dioxide. But the Portable Breathing Apparatus offers no more than 15 minutes of capability, and continued use of hose based supplied oxygen systems increases the oxygen content in a fire situation. NASA has developed a filtering respirator cartridge for use in a fire environment. It is qualified to provide up to 90 minutes of capability, and because it is a filtering respirator it does not add oxygen to the environment. The fire response respirator cartridge does not filter carbon dioxide, so a crew member discharging a CO2 fire extinguisher while wearing this filtering respirator would be at risk of inhaling unsafe levels of CO2. Fine Water Mist extinguishes a fire without creating a large volume of air with reduced oxygen and elevated CO2. Compared to the carbon dioxide based Portable Fire Extinguisher, the flight qualification of Fine Water Mist systems requires special care. Qualification of the CO2 based Portable Fire Extinguisher began with the assumption that any fire on ISS would be extinguished if the air in the fire environment reached a critical concentration of CO2. Qualification of a CO2 based system requires the developers to make assertions and assumptions about vehicle geometry and the ability of the extinguisher to deliver CO2 in different geometric configurations, but the developers did not need to make assertions or assumptions about the size of the fire, the temperature, or the heat generation rate. Fine Water Mist systems extinguish a fire predominantly by removing heat -- so qualification standards must evaluate geometry, but also temperature, heat transfer, and heat generation rate. This paper outlines and describes the methods used to develop standards used to qualify Fine Water Mist systems for a human spaceflight environment.
2012-09-11
CAPE CANAVERAL, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, Fire and Rescue personnel salute as the American flag is raised during the 9/11 memorial dedication ceremony. Kennedy Fire and Rescue Services commemorated the 11th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Kennedy center-wide emergency units dispatched by Fire Control engaged in one-minute sirens, the new memorial was dedicated and the Honor Guard performed a flag-folding ceremony. Photo credit: NASA/Dimitri Gerondidakis
2012-09-11
CAPE CANAVERAL, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, Fire and Rescue personnel salute or stand at attention during a flag folding ceremony at the 9/11 memorial dedication ceremony. Kennedy Fire and Rescue Services commemorated the 11th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Kennedy center-wide emergency units dispatched by Fire Control engaged in one-minute sirens, the new memorial was dedicated and the Honor Guard performed a flag-folding ceremony. Photo credit: NASA/Dimitri Gerondidakis
2012-09-11
CAPE CANAVERAL, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, Fire and Rescue personnel salute as the American flag is raised during the 9/11 memorial dedication ceremony. Kennedy Fire and Rescue Services commemorated the 11th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Kennedy center-wide emergency units dispatched by Fire Control engaged in one-minute sirens, the new memorial was dedicated and the Honor Guard performed a flag-folding ceremony. Photo credit: NASA/Dimitri Gerondidakis
2012-09-11
CAPE CANAVERAL, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, Fire and Rescue personnel salute or stand at attention as the American flag is raised during the 9/11 memorial dedication ceremony. Kennedy Fire and Rescue Services commemorated the 11th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Kennedy center-wide emergency units dispatched by Fire Control engaged in one-minute sirens, the new memorial was dedicated and the Honor Guard performed a flag-folding ceremony. Photo credit: NASA/Dimitri Gerondidakis
2012-09-11
CAPE CANAVERAL, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, Fire and Rescue personnel salute as the American flag is raised during the 9/11 memorial dedication ceremony. Kennedy Fire and Rescue Services commemorated the 11th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Kennedy center-wide emergency units dispatched by Fire Control engaged in one-minute sirens, the new memorial was dedicated and the Honor Guard performed a flag-folding ceremony. Photo credit: NASA/Dimitri Gerondidakis
2012-09-11
CAPE CANAVERAL, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, a new 9/11 memorial was dedicated during a ceremony held by Kennedy’s Fire and Rescue personnel. Kennedy Fire and Rescue Services commemorated the 11th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Kennedy center-wide emergency units dispatched by Fire Control engaged in one-minute sirens, the new memorial was dedicated and the Honor Guard performed a flag-folding ceremony. Photo credit: NASA/Dimitri Gerondidakis
Sustainability and wildland fire: The origins of Forest Service Wildland Fire Research
Diane M. Smith
2017-01-01
On June 1, 2015, the Forest Service, an agency of the U.S. Department of Agriculture (USDA), celebrated the 100th anniversary of the Branch of Research. Established in 1915 to centralize and elevate the pursuit of research throughout the agency, the Branch of Research focused on everything from silvicultural investigations conducted by the experiment stations to...
Paul Meznarich; Jane Smith; Tara Jennings
2013-01-01
Soil health is fundamental to ecosystem health. Disturbances such as fire and timber harvesting can affect the abundance, activity, and composition of soil microbial communities and thus affect soil productivity. In response to forest managers, scientists with the Pacific Northwest Research Station compared health and productivity indicators between soils disturbed by...
2003-01-18
This dramatic image of the Australian brushers was taken from orbit by one of the crew members aboard the International Space Station (ISS). Following the worst regional drought in 50 years, this summer's fire season has resulted in numerous large fires over much of the Great Dividing Range as well as the enormous smoke pall over New South Wales, Victoria, and the adjacent South Pacific Ocean.
Climate change and California: potential implications for vegetation, carbon, and fire.
Jonathan Thompson
2005-01-01
Nineteen scientists from leading research institutes in the United States collaborated to estimate how Californiaâs environment and economy would respond to global climate change. A scientist from the PNW Research Station led efforts to estimate effects on vegetation, carbon, and fire.To quantify the range of the possible effects of climate change over the...
M.A. Callaham; J.M. Blair; T.C. Todd; D.J. Kitchen; M.R. Whiles
2003-01-01
The responses of tallgrass prairie plant communities and ecosystem processes to fire and grazing are well characterized. However, responses of invertebrate consumer groups. and particularly soil-dwelling organisms, to these disturbances are not well known. At Konza Prairie Biological Station. we sampled soil macroinvertebrates in 1994 and 1999 as part of a long-term...
2015-09-11
Rick Anderson, fire chief at NASA's Kennedy Space Center, on podium, left, and Lt. James Dumont lead the dedication service for a memorial to the343 first responder victims of the Sept. 11, 2001, terror attacks at Kennedy's Fire Station 1 on Sept. 11, 2015. The ceremony dedicated a monument that includes a section of steel I-beam from the World Trade Center in New York.
6. Photocopy of photograph (original 53/4 x 31/2 inch negative ...
6. Photocopy of photograph (original 5-3/4 x 3-1/2 inch negative located in the Recreation files, Darrington Ranger District). R. L. Fromme, photographer, July 1942. FIRE & TRUCK STORAGE ('L') BLDG. 2275, FOREGROUND - R. & T. WAREHOUSE, DARRINGTON R.S. ('M') BLDG. 2215, BACKGROUND - Darrington Ranger Station, Fire & Truck Storage Building, 1405 Emmens Street, Darrington, Snohomish County, WA
Rehabilitation of fire-damaged forest lands in southwestern Maine
A. D. Nutting; James C. Rettie; Wayne G. Banks
1949-01-01
Recognizing that it can ill afford the loss of timber productivity on the large acreage of forest land burned over by the 1947 fires, the state of Maine requested assistance of the Northeastern Forest Experiment Station of the United States Forest Service in a program of research that would aid in the rehabilitation of the burned-over forest land.
Melanie Miller
2004-01-01
Fuels planning: science synthesis and integration; environmental consequences fact sheet 5: prescriptions and fire effects. Miller, Melanie. 2004. Res. Note RMRS-RN-23-5-WWW. Fort Collins, CO: U.S. Department of Agriculture, Forest Service, Rocky Mountain Research Station. 2 p. While our understanding of the causes for variation in postfire effects is increasing, burn...
2015-09-11
Rick Anderson, fire chief at NASA's Kennedy Space Center, on podium, left, and Lt. James Dumont lead the dedication service for a memorial to the 343 first responder victims of the Sept. 11, 2001, terror attacks at Kennedy's Fire Station 1 on Sept. 11, 2015. The ceremony dedicated a monument that includes a section of steel I-beam from the World Trade Center in New York.
Photocopy of drawing (this photograph is an 8" x 10" ...
Photocopy of drawing (this photograph is an 8" x 10" copy of an 8" x 10" negative; 1983 original architectural drawing located at Building No. 458, NAS Pensacola, Florida) CORRECT FIRE/SAFETY DEFICIENCIES, BUILDING NO. 1, FIRE PROTECTION CEILING PLANS, SHEET 2 OF 3 - U.S. Naval Air Station, Ship Carpenter's Workshop, 368 South Avenue, Pensacola, Escambia County, FL
Campbell, N R; Jeffrey, P; Kiss, K; Jones, C; Anton, A R
2001-12-01
In 1995, the Calgary Fire Department developed a program to assess blood pressure in community fire stations, selected businesses and public venues. The program has gradually expanded. Currently, all 30 fire stations across Calgary, Alberta assess blood pressures for the public seven days per week throughout the year. Since 1995, there have been 10,883 measurements in 3477 people. Most people (2106) assessed had hypertensive readings, and 72 had readings greater than 220 mmHg systolic or greater than 120 mmHg diastolic, and were referred for immediate medical assessment. The program has been recently integrated into a more global vision for the prevention and control of cardiovascular disease in Calgary. Future plans include offering lipid assessments, assisting other communities to adopt the program and using the program to provide physical measures (of blood pressure, glucose, total and high density lipoprotein cholesterol, height and weight) to an ongoing questionnaire that surveys the health of Calgarians. The history of the program, its training methods, quality control, preliminary results and future plans are presented in detail to provide an example of a community-based program that could aid in the detection, monitoring and awareness of hypertension.
Fire safety applications for spacecraft
NASA Technical Reports Server (NTRS)
Friedman, Robert; Olson, Sandra L.
1989-01-01
Fire safety for spacecraft is reviewed by first describing current practices, many of which are adapted directly from aircraft. Then, current analyses and experimental knowledge in low-gravity combustion, with implications for fire safety are discussed. In orbiting spacecraft, the detection and suppression of flames are strongly affected by the large reduction in buoyant flows under low gravity. Generally, combustion intensity is reduced in low gravity. There are some notable exceptions, however, one example being the strong enhancement of flames by low-velocity ventilation flows in space. Finally, the future requirements in fire safety, particularly the needs of long-duration space stations in fire prevention, detection, extinguishment, and atmospheric control are examined. The goal of spacecraft fire-safety investigations is the establishment of trade-offs that promote maximum safety without hampering the useful human and scientific activities in space.
Advanced spacecraft fire safety: Proposed projects and program plan
NASA Technical Reports Server (NTRS)
Youngblood, Wallace W.; Vedha-Nayagam, M.
1989-01-01
A detailed review identifies spacecraft fire safety issues and the efforts for their resolution, particularly for the threats posed by the increased on-orbit duration, size, and complexity of the Space Station Freedom. Suggestions provided by a survey of Wyle consultants and outside fire safety experts were combined into 30 research and engineering projects. The projects were then prioritized with respect to urgency to meet Freedom design goals, status of enabling technology, cost, and so on, to yield 14 highest priority projects, described in terms of background, work breakdown structure, and schedule. These highest priority projects can be grouped into the thematic areas of fire detection, fire extinguishment, risk assessment, toxicology and human effects, and ground based testing. Recommendations for overall program management stress the need for NASA Headquarters and field center coordination, with information exchange through spacecraft fire safety oversight committees.
Space Station crew safety alternatives study. Volume 2: Threat development
NASA Technical Reports Server (NTRS)
Raasch, R. F.; Peercy, R. L., Jr.; Rockoff, L. A.
1985-01-01
The first 15 years of accumulated space station concepts for initial operational capability (IOC) during the early 1990's were considered. Twenty-five threats to the space station are identified and selected threats addressed as impacting safety criteria, escape and rescue, and human factors safety concerns. Of the 25 threats identified, eight are discussed including strategy options for threat control: fire, biological or toxic contamination, injury/illness, explosion, loss of pressurization, radiation, meteoroid penetration, and debris.
Space station crew safety alternatives study, volume 1
NASA Technical Reports Server (NTRS)
Peercy, R. L., Jr.; Raasch, R. F.; Rockoff, L. A.
1985-01-01
The first 15 years of accumulated space station concepts for initial operational capability (IOC) during the early 1990's were considered. Twenty-five threats to the space station are identified and selected threats addressed as impacting safety criteria, escape and rescue, and human factors safety concerns. Of the 25 threats identified, eight are discussed including strategy options for threat control: fire, biological or toxic contamination, injury/illness, explosion, loss of pressurization, radiation, meteoroid penetration and debris.
Biomass power for rural development. Technical progress report, October 1--December 31, 1997
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neuhauser, E.
The focus of the DOE/USDA sponsored biomass power for rural development project is to develop commercial energy crops for power generation by the year 2000. The New York based Salix Consortium project is a multi-partner endeavor, implemented in three stages. Phase-1, Final Design and Project Development, will conclude with the preparation of construction and/or operating permits, feedstock production plans, and contracts ready for signature. Field trials of willow (Salix) have been initiated at several locations in New York (Tully, Lockport, King Ferry, La Fayette, Massena, and Himrod) and co-firing tests are underway at Greenidge Station (NYSEG) and Dunkirk Station (NMPC).more » Phase-2 of the project will focus on scale-up of willow crop acreage, construction of co-firing facilities at Dunkirk Station (NMPC), and final modifications for Greenidge Station. Cofiring willow is also under consideration for GPU`s Seward Station where testing is underway. There will be an evaluation of the energy crop as part of the gasification trials occurring at BED`s McNeill Power Station. Phase-3 will represent fullscale commercialization of the energy crop and power generation on a sustainable basis. During the fourth quarter of 1997 the Consortium submitted a Phase-2 proposal. A few of the other more important milestones are outlined below. The first quarter of 1998 will be dominated by pre-planting activity in the spring.« less
Low Power Wireless Smoke Alarm System in Home Fires
Luis, Juan Aponte; Galán, Juan Antonio Gómez; Espigado, Javier Alcina
2015-01-01
A novel sensing device for fire detection in domestic environments is presented. The fire detector uses a combination of several sensors that not only detect smoke, but discriminate between different types of smoke. This feature avoids false alarms and warns of different situations. Power consumption is optimized both in terms of hardware and software, providing a high degree of autonomy of almost five years. Data gathered from the device are transmitted through a wireless communication to a base station. The low cost and compact design provides wide application prospects. PMID:26307994
Low Power Wireless Smoke Alarm System in Home Fires.
Aponte Luis, Juan; Gómez Galán, Juan Antonio; Alcina Espigado, Javier
2015-08-21
A novel sensing device for fire detection in domestic environments is presented. The fire detector uses a combination of several sensors that not only detect smoke, but discriminate between different types of smoke. This feature avoids false alarms and warns of different situations. Power consumption is optimized both in terms of hardware and software, providing a high degree of autonomy of almost five years. Data gathered from the device are transmitted through a wireless communication to a base station. The low cost and compact design provides wide application prospects.
2012-09-11
CAPE CANAVERAL, Fla. – A new 9/11 memorial was dedicated in front of Fire Station 1 at NASA’s Kennedy Space Center in Florida. Kennedy Fire and Rescue Services commemorated the 11th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Kennedy center-wide emergency units dispatched by Fire Control engaged in one-minute sirens, the new memorial was dedicated and the Honor Guard performed a flag-folding ceremony. Photo credit: NASA/Dimitri Gerondidakis
2012-06-27
ISS031-E-146391 (27 June 2012) --- An Expedition 31 crew member aboard the International Space Station, flying approximately 240 miles above Earth, recorded a series of images of the current wild fires in the western and southwestern United States. These particular fires, of unknown cause, are burning at the south end of the Wyoming Range in southwestern Wyoming, and have affected 17,000 acres. The fires have produced two major smoke plumes, seen at center of the frame. Utah?s Great Salt Lake (bottom center) is about 120 miles away. Winds transport the smoke in a northeasterly direction.
2010-04-05
201004050001hq (5 April 2010) --- NASA Administrator Charles Bolden looks out the window of Firing Room Four in the Launch Control Center during the launch of the space shuttle Discovery and the start of the STS-131 mission at NASA Kennedy Space Center in Cape Canaveral, Fla. on April 5, 2010. Discovery is carrying a multi-purpose logistics module filled with science racks for the laboratories aboard the International Space Station. The mission has three planned spacewalks, with work to include replacing an ammonia tank assembly, retrieving a Japanese experiment from the station?s exterior, and switching out a rate gyro assembly on the station?s truss structure. Photo Credit: NASA/Bill Ingalls
Shrublands under fire: Disturbance and recovery in a changing world
Stanley G. Kitchen
2008-01-01
These proceedings are part of a series corresponding to fourteen symposia sponsored by the Shrub Research Consortium and published by the U.S. Forest Service, Intermountain Research Station (1983?1996) and Rocky Mountain Research Station (1999 to present). Themes for each symposium were selected to focus on various aspects of the biology, ecology, and management of...
SOXAL{trademark} pilot plant demonstration at Niagara Mohawk`s Dunkirk Station
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strangway, P.K.
This paper describes a six-month, nominal three megawatt (3 MW) pilot plant demonstration of the SOXAL{trademark} regenerative flue gas desulfurization (FGD) process at Niagara Mohawk Power Corporation`s Dunkirk, NY coal-fired power station. Using a slip-stream of flue gas from an actual coal-fired boiler, the pilot plant successfully demonstrated the absorption of sulfur dioxide and the simultaneous regeneration of sodium-based scrubbing liquor via bipolar membrane electrodialysis. Sulfur dioxide removal efficiency of greater than 98% was routinely achieved. The absorption and regeneration stages were both proven reliable and controllable. The pilot plant was successfully operated in both continuous and decoupled modes ofmore » operation, thus demonstrating the flexibility of this process.« less
STS-131 Launch from Firing Room 4
2010-04-05
STS131-S-050 (5 April 2010) --- NASA commentator Mike Curie and astronaut Kathryn (Kay) Hire discuss the launch of space shuttle Discovery on the STS-131 mission in the Launch Control Center's Firing Room 4 at NASA's Kennedy Space Center in Florida. The seven-member STS-131 crew will deliver the multi-purpose logistics module Leonardo, filled with supplies, a new crew sleeping quarters and science racks that will be transferred to the International Space Station's laboratories. The crew also will switch out a gyroscope on the station’s truss structure, install a spare ammonia storage tank and retrieve a Japanese experiment from the station’s exterior. STS-131 is the 33rd shuttle mission to the station and the 131st shuttle mission overall.
Differences in fire danger with altitude, aspect, and time of day
G. L. Hayes
1942-01-01
The measurement of fire danger has progressed remarkably since the early days of measuring humidity alone, or humidity and wind, or humidity, wind, and rain at a few valley bottom stations scattered widely apart over a forest of a million acres or more. Measuring the moisture content of the fuels directly is now known to be more accurate than measuring humidity and...
Rapid Decision Making on the Fire Ground
1988-06-01
Virtually all of the longer decisions are from incidents #30--32, a pumping station fire. This was a unique case in our interviews. First, it took almost...select one. In other words, we found virtually no Instances of the standard laboratory paradigm for decision making: conscious and deliberate...Heidi L. (1985). Eyewitness Memory Enhancement in the Police Interview: Cognitive Retrieval Mnemonics Versus Hypnosis . Journal of Applied Psychology, 70
25. Aerial photograph dated 20 June 1942, showing north end ...
25. Aerial photograph dated 20 June 1942, showing north end of Gould Island from the northeast (caption on photo is in error). Shop and power plant under construction at left, firing pier under construction at far right. Photo courtesy of Naval Undersea Warfare Center, Division Newport, Rhode Island. - Naval Torpedo Station, Firing Pier, North end of Gould Island in Narragansett Bay, Newport, Newport County, RI
Leading Preparedness for Local Fire Agencies
2014-12-01
tsunami that raced across coastal cities including Fukushima where the Fukushima - Daiichi nuclear power station was flooded. The disaster killed more than...emergency preparedness related governmental agencies and increased support at the federal level with a focus on natural disasters .13 The FEMA was...participation has led to increased safety and situational awareness through directed information sharing for all fire response personnel. The core capability of
2015-09-11
Rick Anderson, fire chief at NASA's Kennedy Space Center, on podium, left, and Brevard County Sheriff Wayne Ivey take part in the dedication service for a memorial to the 343 first responder victims of the Sept. 11, 2001, terror attacks at Kennedy's Fire Station 1 on Sept. 11, 2015. The ceremony dedicated a monument that includes a section of steel I-beam from the World Trade Center in New York.
2014-09-11
Cape Canaveral, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, Fire and Rescue personnel gathered near the 9/11 memorial after a ceremony commemorating the 13th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Photo credit: Jim Grossmann
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-10
... SSF diesel generator during a fire for which the SSF is credited. This modification along with... SSF equipment in the event of a failure of the SSF diesel generator during a fire for which the SSF is... provide water to the steam generators of all three units sufficient to remove decay heat following...
Residents' responses to wildland fire programs: a review of cognitive and behavioral studies
James D. Absher; Jerry J. Vaske; Lori B. Shelby
2009-01-01
During the past 8 years the U.S. Forest Serviceâs Pacific Southwest Research Station, in cooperation with Colorado State University has conducted 4 research projects aimed at developing a theoretical and practical understanding of homeownersâ attitudes and behaviors in the Wildland Urban Interface in relation to the threat from wildland fires. Initial work focused on...
Cafferata Peter; Leslie Reid
2013-01-01
For over 50 years, the Caspar Creek Experimental Watersheds, located in western Mendocino County, California, have been the site of long-term cooperative watershed research carried out by the U.S. Forest Service Pacific Southwest Research Station (PSW) and the California Department of Forestry and Fire Protection (CAL FIRE). Preliminary stream flow, suspended...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peffley, R.E.
Developing an operator training program depends on each individual power plant's operating characteristics. This paper deals with the development of the existing, workable program used at the Eckert and Erickson Stations - Board of Water and Light, Lansing, Michigan. The Eckert Station is a coal fired complex consisting of 3 to 45 MW, 3 to 80 MW, and 4 process steam boilers. This training program encompasses seven (7) operating classifications administered by a Head Operator. A similar program is employed at a single unit 160 MW Erickson Station, covering three (3) operating classifications.
Space Station crew safety alternatives study. Volume 4: Appendices
NASA Technical Reports Server (NTRS)
Peercy, R. L., Jr.; Raasch, R. F.; Rockoff, L. A.
1985-01-01
The scope of this study considered the first 15 years of accumulated space station concepts for Initial Operational Capability (10C) during the early 1990's. Twenty-five threats to the space station are identified and selected threats addressed as impacting safety criteria, escape and rescue, and human factors safety concerns. Of the 25 threats identified, eight are discussed including strategy options for threat control: fire, biological or toxic contamination, injury/illness, explosion, loss of pressurization, radiation, meteoroid penetration and debris.
NASA Astrophysics Data System (ADS)
Julià Selvas, Núria; Ninyerola Casals, Miquel
2015-04-01
It has been implemented an automatic system to predict the fire risk in the Principality of Andorra, a small country located in the eastern Pyrenees mountain range, bordered by Catalonia and France, due to its location, his landscape is a set of a rugged mountains with an average elevation around 2000 meters. The system is based on the Fire Weather Index (FWI) that consists on different components, each one, measuring a different aspect of the fire danger calculated by the values of the weather variables at midday. CENMA (Centre d'Estudis de la Neu i de la Muntanya d'Andorra) has a network around 10 automatic meteorological stations, located in different places, peeks and valleys, that measure weather data like relative humidity, wind direction and speed, surface temperature, rainfall and snow cover every ten minutes; this data is sent daily and automatically to the system implemented that will be processed in the way to filter incorrect measurements and to homogenizer measurement units. Then this data is used to calculate all components of the FWI at midday and for the level of each station, creating a database with the values of the homogeneous measurements and the FWI components for each weather station. In order to extend and model this data to all Andorran territory and to obtain a continuous map, an interpolation method based on a multiple regression with spline residual interpolation has been implemented. This interpolation considerer the FWI data as well as other relevant predictors such as latitude, altitude, global solar radiation and sea distance. The obtained values (maps) are validated using a cross-validation leave-one-out method. The discrete and continuous maps are rendered in tiled raster maps and published in a web portal conform to Web Map Service (WMS) Open Geospatial Consortium (OGC) standard. Metadata and other reference maps (fuel maps, topographic maps, etc) are also available from this geoportal.
Co-firing switchgrass in a 50 MW pulverized coal boiler
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ragland, K.W.; Aerts, D.J.; Weiss, C.
1996-12-31
Switchgrass is being co-fired with pulverized coal in a 50 MW wall-fired, radiant boiler at MG&E`s Blount Street generating station. Shredded switchgrass is fed to a hammermill onto a live bottom storage bunker. Twin screw augers move the switchgrass onto a belt conveyor which leads to a rotary air lock valve and through a pressurized pipe to the boiler where it is injected into the furnace at two points between first and second level coal burners. The main objective of the project is to evaluate the boiler performance, slagging behavior, and emissions of the co-fired switchgrass at replacement of ratesmore » of up to 20% by mass (13% by heat input). Initial co-firing tests to examine fuel handling and feeding, combustion behavior, boiler response and emissions are favorable. In November a 100 hour co-fire test is planned.« less
2011-07-06
CAPE CANAVERAL, Fla. -- In the Launch Control Center at NASA's Kennedy Space Center in Florida, Firing Room 3 is serene as launch team members gather at their consoles in Firing Room 4 preparing for space shuttle Atlantis' STS-135 mission to the International Space Station. Atlantis and its crew of four are scheduled to lift off at 11:26 a.m. EDT on July 8 to deliver the Raffaello multi-purpose logistics module packed with supplies and spare parts to the station. The STS-135 mission also will fly a system to investigate the potential for robotically refueling existing satellites and return a failed ammonia pump module to help NASA better understand the failure mechanism and improve pump designs for future systems. STS-135 will be the 33rd flight of Atlantis, the 37th shuttle mission to the space station, and the 135th and final mission of NASA's Space Shuttle Program. For more information visit, www.nasa.gov/mission_pages/shuttle/shuttlemissions/sts135/index.html. Photo credit: NASA/Frankie Martin
Todd A. Rawlinson
2010-01-01
The Rocky Mountain Research Station (RMRS) is studying the effects of fuels reduction treatments on Mexican Spotted Owls and their prey in the Sacramento Mountains of New Mexico. One challenge facing Forest Service managers is that much of the landscape is dominated by overstocked stands resulting from years of fire suppression.
WNYC: 1922-1940-- The Early History of a Twentieth-Century Urban Service.
ERIC Educational Resources Information Center
Luscombe, Irving Foulds
Station WNYC, New York, began operation in 1924 as a means of improving police and fire department services and raising the educational and cultural level of the citizenry. However, Mayor Hylan tried to use WNYC for personal political purposes; and until 1933, under Mayors Walker, McKee, and O'Brien, the station was handicapped by the Hylan…
Hydrologic Effects of the 1988 Galena Fire, Black Hills Area, South Dakota
Driscoll, Daniel G.; Carter, Janet M.; Ohlen, Donald O.
2004-01-01
The Galena Fire burned about 16,788 acres of primarily ponderosa pine forest during July 5-8, 1988, in the Black Hills area of South Dakota. The fire burned primarily within the Grace Coolidge Creek drainage basin and almost entirely within the boundaries of Custer State Park. A U.S. Geological Survey gaging station with streamflow records dating back to 1977 was located along Grace Coolidge Creek within the burned area. About one-half of the gaging station's 26.8-square-mile drainage area was burned. The drainage basin for Bear Gulch, which is tributary to Grace Coolidge Creek, was burned particularly severely, with complete deforestation occurring in nearly the entirety of the area upstream from a gaging station that was installed in 1989. A study to evaluate effects of the Galena Fire on streamflow, geomorphology, and water quality was initiated in 1988. The geomorphologic and water-quality components of the study were completed by 1990 and are summarized in this report. A data-collection network consisting of streamflow- and precipitation-gaging stations was operated through water year 1998 for evaluation of effects on streamflow characteristics, including both annual-yield and peak-flow characteristics, which are the main focus of this report. Moderately burned areas did not experience a substantial increase in the rate of surface erosion; however, severely burned areas underwent surficial erosion nearly twice that of the unburned areas. The sediment production rate of Bear Gulch estimated 8 to 14 months after the fire was 870 ft3/acre (44 tons/acre). Substantial degradation of stream channels within the severely burned headwater areas of Bear Gulch was documented. Farther downstream, channel aggradation resulted from deposition of sediments transported from the headwater areas. The most notable water-quality effect was on concentrations of suspended sediment, which were orders of magnitude higher for Bear Gulch than for the unburned control area. Effects on several other water-quality constituents, such as organic carbon and nitrogen and phosphorus nutrient constituents, probably were influenced by the large concentrations of suspended matter that were documented in initial post-fire, storm-flow events. The first post-fire stormflow produced the highest measured concentrations of specific conductance, nitrogen, phosphorus, organic carbon, calcium, magnesium, potassium, manganese, and sulfate in the burned areas. For most constituents sampled, differences in concentrations between burned and unburned areas were no longer discernible within about 1 year following the Galena Fire. The effects of the Galena Fire on annual-yield characteristics of Grace Coolidge Creek were evaluated primarily from comparisons with long-term streamflow records for Battle Creek, which is hydrogeologically similar and is located immediately to the north. Annual yield for Grace Coolidge Creek increased by about 20 percent as a result of the fire. This estimate was based on relations between annual yield for Grace Coolidge Creek and Battle Creek for pre- and post-burn periods. Many of the post-burn data points are well beyond the range of the pre-burn data, which is a source of uncertainty for this estimate. Substantial increases in peak-flow characteristics for severely burned drainages were visually apparent from numerous post-fire field observations. Various analyses of streamflow data indicated substantial increases in peak-flow response for burned drainage areas; however, quantification of effects was particularly difficult because peak-flow response diminished quickly and returned to a generally pre-burn condition by about 1991. Field observations of vegetation and analysis of remotely sensed data indicated that establishment of grasses and forbs occurred within a similar timeframe. Comparison of pre-fire peak flows to post-1991 peak flows indicates that these grasses and forbs were equally effective in suppressing peak flows
Measuring Wildfires From Aircraft And Satellites
NASA Technical Reports Server (NTRS)
Brass, J. A.; Arvesen, J. C.; Ambrosia, V. G.; Riggan, P. J.; Meyers, J. S.
1991-01-01
Aircraft and satellite systems yield wide-area views, providing total coverage of affected areas. System developed for use aboard aircraft includes digital scanner that records data in 12 channels. Transmits data to ground station for immediate use in fighting fires. Enables researchers to estimate gaseous and particulate emissions from fires. Provides information on temperatures of flame fronts and soils, intensities and rate of spread of fires, characteristics of fuels and smoke plumes, energy-release rates, and concentrations and movements of trace gases. Data relates to heating and cooling of soils, loss of nutrients, and effects on atmospheric, terrestrial, and aquatic systems.
2012-09-11
CAPE CANAVERAL, Fla. – NASA Kennedy Space Center’s Director Robert Cabana participates in a 9/11 memorial dedication in front of Fire Station 1 at Kennedy in Florida. Kennedy Fire and Rescue Services commemorated the 11th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Kennedy center-wide emergency units dispatched by Fire Control engaged in one-minute sirens, the new memorial was dedicated and the Honor Guard performed a flag-folding ceremony. Photo credit: NASA/Dimitri Gerondidakis
Marie Oliver; Becky K. Kerns; Michelle Buonopane
2012-01-01
Scientists have had little information about how prescribed fire and cattle grazingâcommon practices in many Western ponderosa pine forestsâaffects plant abundance and reproduction in the forest understory. Pacific Northwest Research Station scientists began to explore how these practices affect vegetation in a five-year study of postfire vegetation in eastern Oregon...
1952 midsummer fuel moistures in Oregon and Washington national forests compared with other years.
Owen P. Cramer
1953-01-01
The inflammability of Oregon and Washington national forests during the middle of the 1952 fire season was slightly lass than the 12-year record high set in 1951 (table 1). The rating is based on the 25 lowest daily observations of fuel-moisture indicator sticks in the July 16 to August 21 period. Stick readings from 64 key fire-danger stations near the exterior...
Learn from the burn: The High Park Fire 5 years later
Sue Miller; Charles Rhodes; Pete Robichaud; Sandra Ryan; Jen Kovecses; Carl Chambers; Sara Rathburn; Jared Heath; Stephanie Kampf; Codie Wilson; Dan Brogan; Brad Piehl; Mary Ellen Miller; John Giordanengo; Erin Berryman; Monique Rocca
2017-01-01
It has been 5 years since the High Park Fire burned over 85,000 acres in Northern Colorado, causing extensive property damage, loss of life, and severe impacts to the water quality of the Poudre River. In the fall of 2016, a conference was organized by the USFS Rocky Mountain Research Station and the Coalition for the Poudre River Watershed to discuss what has been...
Formulation of low solids coal water slurry from advanced coal cleaning waste fines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Battista, J.J.; Morrison, J.L.; Lambert, A.
1997-07-01
GPU Genco, the New York State Electric and Gas Corporation (NYSEG), Penn State University and the Homer City Coal Processing Corporation are conducting characterization and formulation tests to determine the suitability of using minus 325 mesh coal waste fines as a low solids coal water slurry (CWS) co-firing fuel. The fine coal is contained in a centrifuge effluent stream at the recently modified Homer City Coal Preparation Plant. Recovering, thickening and then co-firing this material with pulverized coal is one means of alleviating a disposal problem and increasing the Btu recovery for the adjacent power plant. The project team ismore » currently proceeding with the design of a pilot scale system to formulate the effluent into a satisfactory co-firing fuel on a continuous basis for combustion testing at Seward Station. The ultimate goal is to burn the fuel at the pulverized coal units at the Homer City Generating Station. This paper presents the success to date of the slurry characterization and pilot scale design work. In addition, the paper will update GPU Genco`s current status for the low solids coal water slurry co-firing technology and will outline the company`s future plans for the technology.« less
Contributions of microgravity test results to the design of spacecraft fire-safety systems
NASA Technical Reports Server (NTRS)
Friedman, Robert; Urban, David L.
1993-01-01
Experiments conducted in spacecraft and drop towers show that thin-sheet materials have reduced flammability ranges and flame-spread rates under quiescent low-gravity environments (microgravity) compared to normal gravity. Furthermore, low-gravity flames may be suppressed more easily by atmospheric dilution or decreasing atmospheric total pressure than their normal-gravity counterparts. The addition of a ventilating air flow to the low-gravity flame zone, however, can greatly enhance the flammability range and flame spread. These results, along with observations of flame and smoke characteristics useful for microgravity fire-detection 'signatures', promise to be of considerable value to spacecraft fire-safety designs. The paper summarizes the fire detection and suppression techniques proposed for the Space Station Freedom and discusses both the application of low-gravity combustion knowledge to improve fire protection and the critical needs for further research.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Aeronautical Multicom Stations § 87.241 Frequencies. (a) 121.500 MHz: emergency and distress only; (b) 122.850... coordinating foresty management and fire suppression, fish and game management and protection, and...
NASA Astrophysics Data System (ADS)
Piketh, S.; Curtis, C.; Pienaar, K.; Khuzwayo, L.; van Zyl, P. G.; Conradie, E.
2016-12-01
South Africa is rich in natural resources that include large deposits of coal. As a result more than 90% of the energy in the country is generated by 13 coal fired power stations located on the Highveld region. Over the past 7 years South Africa has experienced severe power shortages which has resulted in the approval of two new mega coal fired power stations each with a 4800 Mw generating capacity. One of these power stations is at Lephalale in the Waterberg. This region is largely dominated by a natural to semi-natural landscape, but some areas have acid sensitive sub-soils (pH < 5.5) rendering their headwater streams vulnerable to acidification. There are only three other important sources of emissions close to Lephalale, a second coal fired power station, a char plant and domestic coal combustion. In an attempt to determine baseline conditions of air pollution, deposition and stream chemistry impacts prior to the commissioning of the new PS the following measurements have been undertaken, ambient concentrations of SO2, NOx, NH3 and O3 (at seven sites since 2010), rain water chemistry ( at one site for 2015 and 2016) and headwater stream vulnerability (2015 and 2016). Concentrations of sodium (Na+), ammonium (NH4+), potassium (K+), calcium (Ca2+), magnesium (Mg2+), nitrate 21 (NO3-), chloride (Cl-), sulphate (SO42-) in the rain water will be presented and compared to other long term sites around South Africa. Total deposition of S and N will in the Lephalale region will be presented. At least 30 acid-sensitive headwater streams, many with low pH <6 and low acid neutralizing capacity that are extremely sensitive to acid deposition inputs have been identified. Future deposition in the area of acidifying species will be modelled by including emissions from the new Power station and estimates of the potential impact will be assessed.
NASA Technical Reports Server (NTRS)
Ruff, Gary A.
2003-01-01
The purpose of the workshop documented in this publication was to bring together personnel responsible for the design and operations of the International Space Station (ISS) and the fire protection research community to review the current knowledge in fire safety relative to spacecraft. From this review, research needs were identified that were then used to formulate a research plan with specific objectives. In this document, I have attempted to capture the very informative and lively discussions that occurred in the plenary sessions and the working groups. I hope that it will be useful to readers and serve as a significant step in assuring fire protection for the crews of current and future spacecraft.
2010-12-03
CAPE CANAVERAL, Fla. -- The SpaceX Falcon 9 rocket awaits a static fire test on Space Launch Complex-40 at Cape Canaveral Air Force Station, in which all nine Merlin engines will fire at once. The engines use rocket-grade kerosene and liquid oxygen to produce 1 million pounds of thrust. After the test, SpaceX will conduct a thorough review of all data as engineers make final preparations for the first launch of the Commercial Orbital Transportation Services (COTS) Dragon spacecraft to low Earth orbit atop the Falcon 9. This first stage firing is part of a full launch dress rehearsal, which will end after the engines fire at full power for two seconds, with only the hold-down system restraining the rocket from flight. Photo credit: NASA/Rusty Backer
Numerical Simulations of SCR DeNOx System for a 660MW coal-fired power station
NASA Astrophysics Data System (ADS)
Yongqiang, Deng; Zhongming, Mei; Yijun, Mao; Nianping, Liu; Guoming, Yin
2018-06-01
Aimed at the selective catalytic reduction (SCR) DeNOx system of a 660 MW coal-fired power station, which is limited by low denitrification efficiency, large ammonia consumption and over-high ammonia escape rate, numerical simulations were conducted by employing STAR-CCM+ (CFD tool). The simulations results revealed the problems existed in the SCR DeNOx system. Aimed at limitations of the target SCR DeNOx system, factors affecting the denitrification performance of SCR, including the structural parameters and ammonia injected by the ammonia nozzles, were optimized. Under the optimized operational conditions, the denitrification efficiency of the SCR system was enhanced, while the ammonia escape rate was reduced below 3ppm. This study serves as references for optimization and modification of SCR systems.
Final Report to the Department of Energy Renewable Energy and Energy Efficiency
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaughen, Shasta
The Pala Band of Mission Indians was awarded a DOE-EERE Solar Energy Grant for FY 2016 and 2017. The project involved installing a 94.8 kW DC photovoltaic (PC) solar system on the Pala Fire Station to offset up to 95% of grid-derived energy and reduce overall CO 2 generation from the facility. Pala successfully installed rooftop and carport-mounted solar panels at the fire station, and to date has generated of 219,227 kWh of energy and offset 274,034 pounds of CO 2. The project was successfully executed, and we recommend other tribes to undertake similar projects if they are located inmore » areas with sufficient solar exposure. DOE should continue to make these funds available to tribes.« less
NASA Technical Reports Server (NTRS)
Williams, David E.
2008-01-01
The International Space Station (ISS) Node 1 Environmental Control and Life Support (ECLS) System is comprised of five subsystems: Atmosphere Control and Supply (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). This paper provides a summary of the Node 1 Emergency Response capability, which includes nominal and off-nominal FDS operation, off nominal ACS operation, and off-nominal THC operation. These subsystems provide the capability to help aid the crew members during an emergency cabin depressurization, a toxic spill, or a fire. The paper will also provide a discussion of the detailed Node 1 ECLS Element Verification methodologies for operation of the Node 1 Emergency Response hardware operations utilized during the Qualification phase.
STS-131 Launch from Firing Room 4
2010-04-05
STS131-S-055 (5 April 2010) --- Assistant Launch Director Mike Leinbach (right) speaks with NASA commentator Mike Curie in Firing Room 4 in the Launch Control Center at NASA's Kennedy Space Center in Florida prior to the launch of space shuttle Discovery's STS-131 mission. The seven-member STS-131 crew will deliver the multi-purpose logistics module Leonardo, filled with supplies, a new crew sleeping quarters and science racks that will be transferred to the International Space Station's laboratories. The crew also will switch out a gyroscope on the station’s truss structure, install a spare ammonia storage tank and retrieve a Japanese experiment from the station’s exterior. STS-131 is the 33rd shuttle mission to the station and the 131st shuttle mission overall.
Fire and deforestation dynamics in Amazonia (1973-2014).
van Marle, Margreet J E; Field, Robert D; van der Werf, Guido R; Estrada de Wagt, Ivan A; Houghton, Richard A; Rizzo, Luciana V; Artaxo, Paulo; Tsigaridis, Kostas
2017-01-01
Consistent long-term estimates of fire emissions are important to understand the changing role of fire in the global carbon cycle and to assess the relative importance of humans and climate in shaping fire regimes. However, there is limited information on fire emissions from before the satellite era. We show that in the Amazon region, including the Arc of Deforestation and Bolivia, visibility observations derived from weather stations could explain 61% of the variability in satellite-based estimates of bottom-up fire emissions since 1997 and 42% of the variability in satellite-based estimates of total column carbon monoxide concentrations since 2001. This enabled us to reconstruct the fire history of this region since 1973 when visibility information became available. Our estimates indicate that until 1987 relatively few fires occurred in this region and that fire emissions increased rapidly over the 1990s. We found that this pattern agreed reasonably well with forest loss data sets, indicating that although natural fires may occur here, deforestation and degradation were the main cause of fires. Compared to fire emissions estimates based on Food and Agricultural Organization's Global Forest and Resources Assessment data, our estimates were substantially lower up to the 1990s, after which they were more in line. These visibility-based fire emissions data set can help constrain dynamic global vegetation models and atmospheric models with a better representation of the complex fire regime in this region.
Earth Observations taken by the Expedition 15 Crew
2007-08-13
ISS015-E-22276 (13 Aug. 2007) --- Smoke plumes from wide-spread fires across Idaho, Utah and Montana are featured in this image photographed by an Expedition 15 crewmember on the International Space Station while Space Shuttle Endeavour (STS-118) was docked with the station. Looking westward toward the horizon, this image covers an expanse from northern Utah to central Idaho with southwest Montana in the foreground.
Forest research notes, Pacific Northwest Forest Experiment Station, No. 03, October 30, 1929.
1929-01-01
To obtain definite information which can be used in formulating slash disposal policies, the Pacific Northwest Forest Experiment Station has begun a study of the slash problem in the Douglas fir region. Although there are numerous related but widely different aspects to this study, only one phase is treated in this brief summary, namely, the effect of fire on the...
26 CFR 1.528-4 - Substantiality test.
Code of Federal Regulations, 2010 CFR
2010-04-01
... residence. Units which are used for purposes auxiliary to residential use (such as laundry areas, swimming... may be used for parking spaces, swimming pools, tennis courts, schools, fire stations, libraries...
49 CFR 193.2905 - Protective enclosures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... stations; (7) Control systems; (8) Fire control equipment; (9) Security communications systems; and (10... not be located near features outside of the facility, such as trees, poles, or buildings, which could...
NASA Astrophysics Data System (ADS)
Oertel, D.; Haschberger, P.; Tank, V.; Lanzl, F.; Zhukov, B.; Jahn, H.; Briess, K.; Lorenz, E.; Roeser, H.-P.; Ginati, A.; Tobehn, C.; Schulte in den Bäumen, J.; Christmann, U.
1999-01-01
Current and planned operational space-borne Earth observation systems provide spatially, radiometrically or temporally crude data for the detection and monitoring of high temperature phenomena on the surface of our planet. High Temperature Events (HTE) very often cause environmental disasters. Such HTE are forest and savannah fires, fires of open coal mines, volcanic activities and others (e.g. fires of oil wells, pipelines etc.). A simultaneous co-registration of a combination of infrared (IR) and visible (VIS) channels is the key for a reliable autonomous on-board detection of High Temperature Events (HTE) on Earth surface, such as vegetation fires and volcano eruptions. This is the main feature of the FOCUS experiment. Furthermore there are ecology-oriented objectives of the FOCUS experiment mainly related to spectrometric/imaging remote inspection and parameter extraction of selected HTEs, and to the assessment of some ecological consequences of HTEs, such as aerosol and gas emission. Based on own experimental work and supported by Co-Investigators from Italy, Greece, France, Spain, Russia and Germany, DLR proposed in 1997 to use the International Space Station (ISS) in its early utilization phase as a platform and test-bed for an Intelligent Infrared Sensor prototype FOCUS of a future Environmental Disaster Recognition Satellite System. FOCUS is considered by ESA as an important mission combining a number of proven technologies and observation techniques to provide the scientific and operational user community with key data for the classification and monitoring of forest fires. FOCUS was selected as one of five European ``Groupings'' to be flown as an externally mounted payload during the early utilisation phase of the ISS. The FOCUS Phase A Study will be performed by OHB-System, DLR and Zeiss from September 1998 until May 1999.
STS-98 and Expedition One crew with rack in U.S. Laboratory / Destiny module
2001-02-11
STS98-E-5159 (11 February 2001) --- Astronaut Mark L. Polansky, STS-98 pilot, works inside the newly attached Destiny laboratory onboard the International Space Station (ISS). After the Destiny hatch was opened early in the day, members of both the shuttle and station crews went to work quickly inside the new module, activating air systems, fire extinguishers, alarm systems, computers and internal communications. The crews also took some photos and continued equipment transfers from the shuttle to the station. The scene was taken with a digital still camera.
Expedition Five Crew Onboard Photo
NASA Technical Reports Server (NTRS)
2002-01-01
This is a photo of the Hayman Fire burning in the foothills southwest of Denver, Colorado, as viewed by an Expedition Five crewmember aboard the International Space Station (ISS). Astronauts use a variety of lenses and look angles as their orbits pass over the wildfires to document the long-distance movements of smoke from the fires as well as details of the burning areas. In this view, Littleton, Chatfield Lake, and the Arkansas River are all visible.
Assisted Migration as a Management Tool in Coastal Ecosystems Threatened by Climate Change
2016-04-30
upslope migration, the changes in community structure did not include establishment of downslope species. Instead, disturbed assemblages remained...concerns. Pages 134- 141 in Susan I. Cerulean and R. Todd Engstrom, eds. Fire in wetlands: a management perspective. Proceedings of the Tall Timbers Fire...Ecology Conference, No. 19. Tall Timbers Research Station, Tallahassee, FL. Pivovaroff, A. L., C. Swift, L. L. Battaglia, B. Kunz, W. J. Platt, and
Acquisition of wood fuel at the Joseph C. McNeil Generating Station
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kropelin, W.
1993-12-31
The Joseph C. McNeil Generating Station is the world`s largest single boiler, municipally-owned, wood-fired electrical generating plant. The 50 megawatt McNeil Station is located in Burlington, Vermont and is owned by several Vermont public and private electric utilities. The operator and majority owner is the City of Burlington Electric Department (BED). Wood fuel procurement for the McNeil Station has been conducted in an environmentally sensitive way. Harvesting is carried out in conformance with a comprehensive wood chip harvesting policy and monitored by professional foresters. Unpredictable levels of Station operation require rigid adherence to a wood storage plan that minimizes themore » risk of over heating and spontaneous combustion of stockpiled fuel.« less
2017-11-01
From left, Jon Wallace, deputy fire coordinator, U.S. Fish and Wildlife Service Southeast Region, Atlanta, Georgia; Chris Wilcox, U.S. Fish and Wildlife chief, Fire Management, National Interagency Fire Center, Boise, Idaho; and Mark Schollmeyer, chief, Brevard County Fire Rescue, pose for a portrait following a ceremony Nov. 1 on the Merritt Island National Wildlife Refuge in Florida. During the joint ceremony, the Spaceport Integration Team and its partners were presented with the prestigious 2017 Pulaski Award and a new memorial marker was dedicated. The multi-agency team includes representatives from NASA's Kennedy Space Center, Cape Canaveral Air Force Station's 45th Space Wing, the Merritt Island National Wildlife Refuge, as well as the Florida Forest Service and Brevard County Fire Rescue. The memorial marker honors two fallen firefighters, Scott Maness and Beau Sauselein, who died fighting a wildfire on space center property in 1981. Held outdoors, the ceremony was attended by 140 guests.
Contributions of Microgravity Test Results to the Design of Spacecraft Fire Safety Systems
NASA Technical Reports Server (NTRS)
Friedman, Robert; Urban, David L.
1993-01-01
Experiments conducted in spacecraft and drop towers show that thin-sheet materials have reduced flammability ranges and flame-spread rates under quiescent low-gravity environments (microgravity) as compared to normal gravity. Furthermore, low-gravity flames may be suppressed more easily by atmospheric dilution or decreasing atmospheric total pressure than their normal-gravity counterparts. The addition of a ventilating air flow to the low-gravity flame zone, however, can greatly enhance the flammability range and flame spread. These results, along with observations of flame and smoke characteristics useful for microgravity fire-detection 'signatures', promise to be of considerable value to spacecraft fire-safety designs. The paper summarizes the fire detection and suppression techniques proposed for the Space Station Freedom and discusses both the application of low-gravity combustion knowledge to improve fire protection and the critical needs for further research.
NASA Astrophysics Data System (ADS)
Davies, D.; Wong, M.; Ilavajhala, S.; Molinario, G.; Justice, C. O.
2012-12-01
This paper discusses the broad uptake of MODIS near-real-time (NRT) active fire data for applications. Prior to the launch of MODIS most real-time satellite-derived fire information was obtained from NOAA AVHRR via direct broadcast (DB) systems. Whilst there were efforts to make direct broadcast stations affordable in developing countries, such as through the Local Applications of Satellite Remote Technologies (LARST), these systems were relatively few and far between and required expertise to manage and operate. One such system was in Etosha National Park (ENP) in Namibia. Prior to the installation of the AVHRR DB system in ENP, fires were reported by rangers and the quality, accuracy and timing of reports was variable. With the introduction of the DB station, early warning of fires improved and fire maps could be produced for park managers within 2-3 hours by staff trained to process data, interpret images and produce maps. Up keep and maintenance of such systems was relatively costly for parks with limited resources therefore when global fire data from MODIS became available uptake was widespread. NRT data from MODIS became availalbe through a collaboration between the MODIS Fire Team and the US Forest Service (USFS) Remote Sensing Applications Center to provide rapid access to imagery to help fight the Montana wildfires of 2001. This prompted the development of a Rapid Response System for fire data that eventually led to the operational use of MODIS data by the USFS for fire monitoring. Building on this success, the Fire Information for Resource Management System (FIRMS) project was funded by NASA Applications, and developed under the umbrella of the GOFC-GOLD Fire program, to further improve products and services for the global fire information community. FIRMS was developed as a web-based geospatial tool, offering a range of geospatial data services, including a fire email alert service which is widely used around the world. FIRMS was initially developed to meet the needs of protected area managers, who like the managers in ENP had limited resources to cover large, remote areas. It was quickly realized that these data could be used for a wide range of applications beyond wildfire management including ecological studies, informing fire policy and public outreach. Today, FIRMS sends approximately 2000 email alerts daily to users in over 120 countries. In addition to the direct users of the MODIS fire data, there are a growing number of brokers who add value to the data, by combining them with targeted geospatial information and re-distribute the information. In addition to the English, French and Spanish fire notifications sent out by FIRMS, some brokers translate the alerts in to local languages and distribute them in Thailand, Indonesia, Russia and India.
SOUTH (SIDE) AND WEST (REAR) ELEVATIONS OF BUILDING. VIEW TO ...
SOUTH (SIDE) AND WEST (REAR) ELEVATIONS OF BUILDING. VIEW TO NORTH. - Plattsburgh Air Force Base, Fire Station, Off Alabama Avenue, between Arkansas Street & Idaho Avenue, Plattsburgh, Clinton County, NY
EAST (FRONT) AND SOUTH (SIDE) ELEVATIONS OF BUILDING. VIEW TO ...
EAST (FRONT) AND SOUTH (SIDE) ELEVATIONS OF BUILDING. VIEW TO WEST. - Plattsburgh Air Force Base, Fire Station, Off Alabama Avenue, between Arkansas Street & Idaho Avenue, Plattsburgh, Clinton County, NY
EAST (FRONT) AND NORTH (SIDE) ELEVATIONS OF BUILDING. VIEW TO ...
EAST (FRONT) AND NORTH (SIDE) ELEVATIONS OF BUILDING. VIEW TO SOUTH. - Plattsburgh Air Force Base, Fire Station, Off Alabama Avenue, between Arkansas Street & Idaho Avenue, Plattsburgh, Clinton County, NY
NORTH (SIDE) AND WEST (REAR) ELEVATIONS OF BUILDING. VIEW TO ...
NORTH (SIDE) AND WEST (REAR) ELEVATIONS OF BUILDING. VIEW TO SOUTHEAST. - Plattsburgh Air Force Base, Fire Station, Off Alabama Avenue, between Arkansas Street & Idaho Avenue, Plattsburgh, Clinton County, NY
... 5 centimeters) forward or sideways. Contact your local police or fire station for help installing your seat. ... Durbin DR; Committee on Injury, Violence, and Poison Prevention. Child ... PMID: 21422094 www.ncbi.nlm.nih.gov/pubmed/21422094 . ...
Tsunami Research Program | PEER Center
including coastal bridges, and important public facilities (fire and police stations, hospitals, and schools ). Failure of critical coastal structures and lifelines likely lead to loss of life, delays in emergency
2012-09-11
CAPE CANAVERAL, Fla. – At Fire Station 1 at NASA’s Kennedy Space Center in Florida, a horseless carriage in memory of firefighters lost on 9/11 is on display during the 9/11 memorial dedication ceremony. Kennedy Fire and Rescue Services commemorated the 11th anniversary of 9/11 with a ceremony that included a minute of silence at 10:28 a.m., which was the moment of collapse of the north tower of the World Trade Center. Kennedy center-wide emergency units dispatched by Fire Control engaged in one-minute sirens, the new memorial was dedicated and the Honor Guard performed a flag-folding ceremony. Photo credit: NASA/Dimitri Gerondidakis
Fire and Deforestation Dynamics in South America over the Past 50 Years
NASA Astrophysics Data System (ADS)
van Marle, M.; Field, R. D.; van der Werf, G.
2015-12-01
Fires play an important role in the Earth system and are one of the major sources of greenhouse gases and aerosols. Satellites have been key to understand their spatial and temporal variability in space and time, but the most frequently used satellite datasets start only in 1995. There are still large uncertainties about the frequency and intensity of fires in the pre-satellite time period, especially in regions with active deforestation, which may have changed dramatically in intensity in the past decades influencing fire dynamics. We used two datasets to extend the record of fires and deforestation in the Amazon region back in time: 1) annual forest loss rates starting in 1990 derived from Vegetation Optical Depth (VOD), which is a satellite-based vegetation product that can be used as proxy for forest loss, and 2) horizontal visibility as proxy for fire emissions, reported by weather stations and airports in the Amazon, which started around 1940, and having widespread coverage since 1973. We show that these datasets overlap with fire emission estimates from the Global Fire Emissions Database (GFED) enabling us to estimate fire emissions over the last 50 years. We will discuss how fires have varied over time in this region with globally significant emissions, how droughts have influenced fire activity and deforestation rates, and what the impact is of land-use change caused by fire on emissions in the Amazon region.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bearden, Mark D.; Davidson, Casie L.; Horner, Jacob A.
Presented here are the results of a techno-economic (TEA) study of the potential for coupling low-grade geothermal resources to boost the electrical output from coal-fired power plants. This study includes identification of candidate 500 MW subcritical coal-fired power plants in the continental United States, followed by down-selection and characterization of the North Valmy generating station, a Nevada coal-fired plant. Based on site and plant characteristics, ASPEN Plus models were designed to evaluate options to integrate geothermal resources directly into existing processes at North Valmy. Energy outputs and capital costing are presented for numerous hybrid strategies, including integration with Organic Rankinemore » Cycles (ORCs), which currently represent the primary technology for baseload geothermal power generation.« less
A Thermal Precipitator for Fire Characterization Research
NASA Technical Reports Server (NTRS)
Meyer, Marit; Bryg, Vicky
2008-01-01
Characterization of the smoke from pyrolysis of common spacecraft materials provides insight for the design of future smoke detectors and post-fire clean-up equipment on the International Space Station. A thermal precipitator was designed to collect smoke aerosol particles for microscopic analysis in fire characterization research. Information on particle morphology, size and agglomerate structure obtained from these tests supplements additional aerosol data collected. Initial modeling for the thermal precipitator design was performed with the finite element software COMSOL Multiphysics, and includes the flow field and heat transfer in the device. The COMSOL Particle Tracing Module was used to determine particle deposition on SEM stubs which include TEM grids. Modeling provided optimized design parameters such as geometry, flow rate and temperatures. Microscopy results from fire characterization research using the thermal precipitator are presented.
2010-12-03
CAPE CANAVERAL, Fla. -- The SpaceX Falcon 9 rocket awaits a static fire test on Space Launch Complex-40 at Cape Canaveral Air Force Station, in which all nine Merlin engines will fire at once. The engines use rocket-grade kerosene and liquid oxygen to produce 1 million pounds of thrust. After the test, SpaceX will conduct a thorough review of all data as engineers make final preparations for the first launch of the Commercial Orbital Transportation Services (COTS) Dragon spacecraft to low Earth orbit atop the Falcon 9. This first stage firing is part of a full launch dress rehearsal, which will end after the engines fire at full power for two seconds, with only the hold-down system restraining the rocket from flight. Photo credit: NASA/Tony Gray and Kevin O'Connell
2010-12-04
CAPE CANAVERAL, Fla. -- During a static fire test on Space Launch Complex-40 at Cape Canaveral Air Force Station, all nine Merlin engines of the SpaceX Falcon 9 rocket fire at once. The engines use rocket-grade kerosene and liquid oxygen to produce 1 million pounds of thrust. After the test, SpaceX began to conduct a thorough review of all data as engineers make final preparations for the first launch of the Commercial Orbital Transportation Services (COTS) Dragon spacecraft to low Earth orbit atop the Falcon 9. This first stage firing is part of a full launch dress rehearsal, which ended after the engines fired at full power for two seconds, with only the hold-down system restraining the rocket from flight. Photo credit: NASA/Tony Gray and Kevin O'Connell
2010-12-04
CAPE CANAVERAL, Fla. -- During a static fire test on Space Launch Complex-40 at Cape Canaveral Air Force Station, all nine Merlin engines of the SpaceX Falcon 9 rocket fire at once. The engines use rocket-grade kerosene and liquid oxygen to produce 1 million pounds of thrust. After the test, SpaceX began to conduct a thorough review of all data as engineers make final preparations for the first launch of the Commercial Orbital Transportation Services (COTS) Dragon spacecraft to low Earth orbit atop the Falcon 9. This first stage firing is part of a full launch dress rehearsal, which ended after the engines fired at full power for two seconds, with only the hold-down system restraining the rocket from flight. Photo credit: NASA/Tony Gray and Kevin O'Connell
2010-12-04
CAPE CANAVERAL, Fla. -- During a static fire test on Space Launch Complex-40 at Cape Canaveral Air Force Station, all nine Merlin engines of the SpaceX Falcon 9 rocket fire at once. The engines use rocket-grade kerosene and liquid oxygen to produce 1 million pounds of thrust. After the test, SpaceX began to conduct a thorough review of all data as engineers make final preparations for the first launch of the Commercial Orbital Transportation Services (COTS) Dragon spacecraft to low Earth orbit atop the Falcon 9. This first stage firing is part of a full launch dress rehearsal, which ended after the engines fired at full power for two seconds, with only the hold-down system restraining the rocket from flight. Photo credit: NASA/Tony Gray and Kevin O'Connell
2. Detail of tower foundation with lightning transfer wire, southeast ...
2. Detail of tower foundation with lightning transfer wire, southeast corner - Cold Mountain Fire Lookout Station, Lookout Tower, Krassel District, Frank Church River of No Return Wilderness, Dixie, Idaho County, ID
Fire and deforestation dynamics in Amazonia (1973–2014)
Field, Robert D.; van der Werf, Guido R.; Estrada de Wagt, Ivan A.; Houghton, Richard A.; Rizzo, Luciana V.; Artaxo, Paulo; Tsigaridis, Kostas
2017-01-01
Abstract Consistent long‐term estimates of fire emissions are important to understand the changing role of fire in the global carbon cycle and to assess the relative importance of humans and climate in shaping fire regimes. However, there is limited information on fire emissions from before the satellite era. We show that in the Amazon region, including the Arc of Deforestation and Bolivia, visibility observations derived from weather stations could explain 61% of the variability in satellite‐based estimates of bottom‐up fire emissions since 1997 and 42% of the variability in satellite‐based estimates of total column carbon monoxide concentrations since 2001. This enabled us to reconstruct the fire history of this region since 1973 when visibility information became available. Our estimates indicate that until 1987 relatively few fires occurred in this region and that fire emissions increased rapidly over the 1990s. We found that this pattern agreed reasonably well with forest loss data sets, indicating that although natural fires may occur here, deforestation and degradation were the main cause of fires. Compared to fire emissions estimates based on Food and Agricultural Organization's Global Forest and Resources Assessment data, our estimates were substantially lower up to the 1990s, after which they were more in line. These visibility‐based fire emissions data set can help constrain dynamic global vegetation models and atmospheric models with a better representation of the complex fire regime in this region. PMID:28286373
Fire protection for launch facilities using machine vision fire detection
NASA Astrophysics Data System (ADS)
Schwartz, Douglas B.
1993-02-01
Fire protection of critical space assets, including launch and fueling facilities and manned flight hardware, demands automatic sensors for continuous monitoring, and in certain high-threat areas, fast-reacting automatic suppression systems. Perhaps the most essential characteristic for these fire detection and suppression systems is high reliability; in other words, fire detectors should alarm only on actual fires and not be falsely activated by extraneous sources. Existing types of fire detectors have been greatly improved in the past decade; however, fundamental limitations of their method of operation leaves open a significant possibility of false alarms and restricts their usefulness. At the Civil Engineering Laboratory at Tyndall Air Force Base in Florida, a new type of fire detector is under development which 'sees' a fire visually, like a human being, and makes a reliable decision based on known visual characteristics of flames. Hardware prototypes of the Machine Vision (MV) Fire Detection System have undergone live fire tests and demonstrated extremely high accuracy in discriminating actual fires from false alarm sources. In fact, this technology promises to virtually eliminate false activations. This detector could be used to monitor fueling facilities, launch towers, clean rooms, and other high-value and high-risk areas. Applications can extend to space station and in-flight shuttle operations as well; fiber optics and remote camera heads enable the system to see around obstructed areas and crew compartments. The capability of the technology to distinguish fires means that fire detection can be provided even during maintenance operations, such as welding.
Fire protection for launch facilities using machine vision fire detection
NASA Technical Reports Server (NTRS)
Schwartz, Douglas B.
1993-01-01
Fire protection of critical space assets, including launch and fueling facilities and manned flight hardware, demands automatic sensors for continuous monitoring, and in certain high-threat areas, fast-reacting automatic suppression systems. Perhaps the most essential characteristic for these fire detection and suppression systems is high reliability; in other words, fire detectors should alarm only on actual fires and not be falsely activated by extraneous sources. Existing types of fire detectors have been greatly improved in the past decade; however, fundamental limitations of their method of operation leaves open a significant possibility of false alarms and restricts their usefulness. At the Civil Engineering Laboratory at Tyndall Air Force Base in Florida, a new type of fire detector is under development which 'sees' a fire visually, like a human being, and makes a reliable decision based on known visual characteristics of flames. Hardware prototypes of the Machine Vision (MV) Fire Detection System have undergone live fire tests and demonstrated extremely high accuracy in discriminating actual fires from false alarm sources. In fact, this technology promises to virtually eliminate false activations. This detector could be used to monitor fueling facilities, launch towers, clean rooms, and other high-value and high-risk areas. Applications can extend to space station and in-flight shuttle operations as well; fiber optics and remote camera heads enable the system to see around obstructed areas and crew compartments. The capability of the technology to distinguish fires means that fire detection can be provided even during maintenance operations, such as welding.
Earth Observation taken during the Expedition 36 mission
2013-08-24
ISS036-E-035677 (24 Aug. 2013) --- One of the Expedition 36 crew members aboard the International Space Station used a 50mm lens to record this high oblique view of the massive drought-aided Rim Fire in and around California's Yosemite National Park and the Stanislaus National Forest on Aug. 24. Editor's Note: The fire began on Aug. 17 and, as of Aug. 26, continues to burn. More than 224 square miles have been affected.
Temperature monitoring and Forest Fires in Góis Council, Portugal
NASA Astrophysics Data System (ADS)
Rodrigues, M. A. S.; Costa, M. E. G.
2012-04-01
In our school the activities linked with sciences are developed in a partnership with other school subjects. Interdisciplinary projects are always valued from beginning to end of a project. It is common for teachers of different areas to work together in a Science project. Research of English written articles is very important not only for the development of our students' scientific literacy but also as a way of widening knowledge and a view on different perspectives of life instead of being limited to research of any articles in Portuguese language. As in this area there is a strong occurrence of forest fires, we are going to study the influence of temperature and its occurrence. For this study we have selected six meteorological stations, distributed through the region and placed in different altitudes. Through the analysis of the temperatures we have verified the lack of data from some stations, so we have proceeded to the homogenisation of the series, using the correlation coefficient of a reference series. In a second stage we will analyse forest fires episodes in the region, with data collected from the Civil Protection and the Meteorological Institute from 1980 to 2010 and correlate this with the series of temperatures for the different areas selected for this study. This research allows an evaluation of the forest fire propagation in the region and recognise the most affected areas.
Warm Dry Weather Conditions Cause of 2016 Fort McMurray Wild Forest Fire and Associated Air Quality
NASA Astrophysics Data System (ADS)
de Azevedo, S. C.; Singh, R. P.; da Silva, E. A., Sr.
2016-12-01
The climate change is evident from the increasing temperature around the world, day to day life and increasing frequency of natural hazards. The warm and dry conditions are the cause of frequent forest fires around the globe. Forest fires severely affect the air quality and human health. Multi sensor satellites and dense network of ground stations provide information about vegetation health, meteorological, air quality and atmospheric parameters. We have carried out detailed analysis of satellite and ground data of wild forest fire that occurred in May 2016 in Fort McMurray, Alberta, Canada. This wild forest fire destroyed 10 per cent of Fort McMurray's housing and forced more than 90,000 people to evacuate the surrounding areas. Our results show that the warm and dry conditions with low rainfall were the cause of Fort McMurray wild fire. The air quality parameters (particulate matter, CO, ozone, NO2, methane) and greenhouse gases measured from Atmospheric Infrared Sounder (AIRS) satellite show enhanced levels soon after the forest fire. The emissions from the forest fire affected health of population living in surrounding areas up to 300 km radius.
Russell, Marie C; Belle, Jessica H; Liu, Yang
2017-01-01
Relative to the rest of the United States, the region of southwestern Pennsylvania, including metropolitan Pittsburgh, experiences high ambient concentrations of fine particulate matter (PM 2.5 ), which is known to be associated with adverse respiratory and cardiovascular health impacts. This study evaluates whether the closing of three coal-fired power plants within the southwestern Pennsylvania region resulted in a significant decrease in PM 2.5 concentration. Both PM 2.5 data obtained from EPA ground stations in the study region and aerosol optical depth (AOD) data retrieved from the Moderate Resolution Imaging Spectroradiometer (MODIS) instruments onboard the Terra and Aqua satellites were used to investigate regional air quality from January 2011 through December 2014. The impact of the plant closings on PM 2.5 concentration and AOD was evaluated using a series of generalized additive models. The model results show that monthly fuel consumption of the Elrama plant, which closed in October of 2012, and monthly fuel consumption of both the Mitchell and Hatfield's Ferry plants, which closed in October of 2013, were significant predictors of both PM 2.5 concentration and AOD at EPA ground stations in the study region, after controlling for multiple meteorological factors and long-term, region-wide air quality improvements. The model's power to predict PM 2.5 concentration increased from an adjusted R 2 of 0.61 to 0.68 after excluding data from ground stations with higher uncertainty due to recent increases in unconventional natural gas extraction activities. After preliminary analyses of mean PM 2.5 concentration and AOD showed a downward trend following each power plant shutdown, results from a series of generalized additive models confirmed that the activity of the three plants that closed, measured by monthly fuel consumption, was highly significant in predicting both AOD and PM 2.5 at 12 EPA ground stations; further research on PM 2.5 emissions from unconventional natural gas extraction is needed. With many coal-fired power plants scheduled to close across the United States in the coming years, there is interest in the potential impact on regional PM 2.5 concentrations. In southwestern Pennsylvania, recent coal-fired power plant closings were coupled with a boom in unconventional natural gas extraction. Natural gas is currently seen as an economically viable bridge fuel between coal and renewable energy. This study provides policymakers with more information on the potential ambient concentration changes associated with coal-fired power plant closings as the nation's energy reliance shifts toward natural gas.
NASA Astrophysics Data System (ADS)
Westberg, David; Soja, Amber; Stackhouse, Paul, Jr.
2010-05-01
Fire is the dominant disturbance that precipitates ecosystem change in boreal regions, and fire is largely under the control of weather and climate. Boreal systems contain the largest pool of terrestrial carbon, and Russia holds 2/3 of the global boreal forests. Fire frequency, fire severity, area burned and fire season length are predicted to increase in boreal regions under climate change scenarios. Meteorological parameters influence fire danger and fire is a catalyst for ecosystem change. Therefore to predict fire weather and ecosystem change, we must understand the factors that influence fire regimes and at what scale these are viable. Our data consists of NASA Langley Research Center (LaRC)-derived fire weather indices (FWI) and National Climatic Data Center (NCDC) surface station-derived FWI on a domain from 50°N-80°N latitude and 70°E-170°W longitude and the fire season from April through October for the years of 1999, 2002, and 2004. Both of these are calculated using the Canadian Forest Service (CFS) FWI, which is based on local noon surface-level air temperature, relative humidity, wind speed, and daily (noon-noon) rainfall. The large-scale (1°) LaRC product uses NASA Goddard Earth Observing System version 4 (GEOS-4) reanalysis and NASA Global Precipitation Climatology Project (GEOS-4/GPCP) data to calculate FWI. CFS Natural Resources Canada uses Geographic Information Systems (GIS) to interpolate NCDC station data and calculate FWI. We compare the LaRC GEOS- 4/GPCP FWI and CFS NCDC FWI based on their fraction of 1° grid boxes that contain satellite-derived fire counts and area burned to the domain total number of 1° grid boxes with a common FWI category (very low to extreme). These are separated by International Geosphere-Biosphere Programme (IGBP) 1°x1° resolution vegetation types to determine and compare fire regimes in each FWI/ecosystem class and to estimate the fraction of each of the 18 IGBP ecosystems burned, which are dependent on the FWI. On days with fire counts, the domain total of 1°x1° grid boxes with and without daily fire counts and area burned are totaled. The fraction of 1° grid boxes with fire counts and area burned to the total number of 1° grid boxes having common FWI category and vegetation type are accumulated, and a daily mean for the burning season is calculated. The mean fire counts and mean area burned plots appear to be well related. The ultimate goal of this research is to assess the viability of large-scale (1°) data to be used to assess fire weather danger and fire regimes, so these data can be confidently used to predict future fire regimes using large-scale fire weather data. Specifically, we related large-scale fire weather, area burned, and the amount of fire-induced ecosystem change. Both the LaRC and CFS FWI showed gradual linear increase in fraction of grid boxes with fire counts and area burned with increasing FWI category, with an exponential increase in the higher FWI categories in some cases, for the majority of the vegetation types. Our analysis shows a direct correlation between increased fire activity and increased FWI, independent of time or the severity of the fire season. During normal and extreme fire seasons, we noticed the fraction of fire counts and area burned per 1° grid box increased with increasing FWI rating. Given this analysis, we are confident large-scale weather and climate data, in this case from the GEOS-4 reanalysis and the GPCP data sets, can be used to accurately assess future fire potential. This increases confidence in the ability of large-scale IPCC weather and climate scenarios to predict future fire regimes in boreal regions.
Parks, Sean A; Holsinger, Lisa M; Miller, Carol; Nelson, Cara R
2015-09-01
Theory suggests that natural fire regimes can result in landscapes that are both self-regulating and resilient to fire. For example, because fires consume fuel, they may create barriers to the spread of future fires, thereby regulating fire size. Top-down controls such as weather, however, can weaken this effect. While empirical examples demonstrating this pattern-process feedback between vegetation and fire exist, they have been geographically limited or did not consider the influence of time between fires and weather. The availability of remotely sensed data identifying fire activity over the last four decades provides an opportunity to explicitly quantify-the ability of wildland fire to limit the progression of subsequent fire. Furthermore, advances in fire progression mapping now allow an evaluation of how daily weather as a top-down control modifies this effect. In this study, we evaluated the ability of wildland fire to create barriers that limit the spread of subsequent fire along a gradient representing time between fires in four large study areas in the western United States. Using fire progression maps in conjunction with weather station data, we also evaluated the influence of daily weather. Results indicate that wildland fire does limit subsequent fire spread in all four study areas, but this effect decays over time; wildland fire no longer limits subsequent fire spread 6-18 years after fire, depending on the study area. We also found that the ability of fire to regulate, subsequent fire progression was substantially reduced under extreme conditions compared to moderate weather conditions in all four study areas. This study increases understanding of the spatial feedbacks that can lead to self-regulating landscapes as well as the effects of top-down controls, such as weather, on these feedbacks. Our results will be useful to managers who seek to restore natural fire regimes or to exploit recent burns when managing fire.
jsc2017m000677_SpeedyTime2–Advanced_ Resistive_Exercise_ Device
2017-07-20
SpeedyTime #2 – Advanced Resistive Exercise Device Astronauts on the International Space Station have to exercise for two hours every day, but they can show off the hardware in a lot less time than that. In this “SpeedyTime” segment Expedition 52 flight engineer Peggy Whitson gives us a rapid-fire display of exercises that can be done with just one piece of equipment, the Advanced Resistive Exercise Device in the Tranquility module. _______________________________________ FOLLOW THE SPACE STATION! Twitter: https://twitter.com/Space_Station Facebook: https://www.facebook.com/ISS Instagram: https://instagram.com/iss/
Space station crew safety alternatives study. Volume 3: Safety impact of human factors
NASA Technical Reports Server (NTRS)
Rockoff, L. A.; Raasch, R. F.; Peercy, R. L., Jr.
1985-01-01
The first 15 years of accumulated space station concepts for Initial Operational Capability (IOC) during the early 1990's was considered. Twenty-five threats to the space station are identified and selected threats addressed as impacting safety criteria, escape and rescue, and human factors safety concerns. Of the 25 threats identified, eight are discussed including strategy options for threat control: fire, biological or toxic contamination, injury/illness, explosion, loss of pressurization, radiation, meteoroid penetration and debris. Of particular interest here is volume three (of five volumes) pertaining to the safety impact of human factors.
Identifying atmospheric monitoring needs for Space Station Freedom
NASA Technical Reports Server (NTRS)
Casserly, Dennis M.
1989-01-01
The atmospheric monitoring needs for Space Station Freedom were identified by examining the following from an industrial hygiene perspective: the experiences of past missions; ground based tests of proposed life support systems; the unique experimental and manufacturing facilities; the contaminant load model; metabolic production; and a fire. A target list of compounds to be monitored is presented and information is provided relative to the frequency of analysis, concentration ranges, and locations for monitoring probes.
Physical and Chemical Aspects of Fire Suppression in Extraterrestrial Environments
NASA Technical Reports Server (NTRS)
Takahashi, F.; Linteris, G. T.; Katta, V. R.
2001-01-01
A fire, whether in a spacecraft or in occupied spaces on extraterrestrial bases, can lead to mission termination or loss of life. While the fire-safety record of US space missions has been excellent, the advent of longer duration missions to Mars, the moon, or aboard the International Space Station (ISS) increases the likelihood of fire events, with more limited mission termination options. The fire safety program of NASA's manned space flight program is based largely upon the principles of controlling the flammability of on-board materials and greatly eliminating sources of ignition. As a result, very little research has been conducted on fire suppression in the microgravity or reduced-gravity environment. The objectives of this study are: to obtain fundamental knowledge of physical and chemical processes of fire suppression, using gravity and oxygen concentration as independent variables to simulate various extraterrestrial environments, including spacecraft and surface bases in Mars and moon missions; to provide rigorous testing of analytical models, which include comprehensive descriptions of combustion and suppression chemistry; and to provide basic research results useful for technological advances in fire safety, including the development of new fire-extinguishing agents and approaches, in the microgravity environment associated with ISS and in the partial-gravity Martian and lunar environments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hughes, E.; Tillman, D.
1997-12-01
Cofiring is considered to be the most promising near-term approach to fossil C0{sub 2} emissions mitigation through biomass usage. Consequently FETC and EPRI have entered into a cooperative agreement: `Cofiring Biomass and Waste-Derived fuels in Electric Utility Coal- Fired Boilers.` This agreement supports sixteen (16) EPRI research projects, each contributing to the commercialization of systems to address greenhouse gas emissions. These projects include: (1) cofiring combustion testing at the Seward Generating Station of GPU Genco; (2) fuel preparation testing at the Greenidge Generating Station of NYSEG; (3) precommercial testing of cofiring at the Allen and Colbert Fossil Plants of TVA;more » (4) testing of switchgrass cofiring at the Blount St. Station of Madison Gas & Electric; (5) high percentage biomass cofiring with Southern Company; (6) urban wood waste cofiring at the supercritical cyclone boiler at Michigan City Generating Station of Northern Indiana Public Service Co. (NIPSCO); (7) evaluation of switchgrass cofiring with Nebraska Public Power District at Sandia National Laboratories in Livermore, CA; (8) waste plastics cofiring with Duke Power in a tangentially-fired pulverized coal (PC) boiler; (9) cofiring a mixture of plastics, fiber, and pulp industry wastes with South Carolina Electric and Gas; (10) urban wood waste cofiring evaluation and testing by the University of Pittsburgh in stoker boilers; (11) assessment of toxic emissions from cofiring of wood and coal; (12) development of fuel and power plant models for analysis and interpretation of cofiring results; (13) analysis of C0{sub 2} utilization in algal systems for wastewater treatment; (14) combustion testing and combustor development focusing on high percentage cofiring; (15) analysis of problems and potential solutions to the sale of flyash from coal-fired boilers practicing cofiring; and (16) analysis of C0{sub 2} capture and disposal systems. During the second quarter of this contract, from January 1, 1997 through March 31, 1997, significant progress has been made on these projects. This progress focuses upon analysis of data from the cofiring tests, construction of systems to promote additional cofiring tests, and initiation of tasks evaluating alternatives to cofiring. This report contains a brief description of the progress made during the second quarter of the contract, focusing upon test results from the Seward Generating Station, where parametric testing at a wall-fired PC boiler was used to evaluate cofiring using separate feeding of wood and coal to the energy generation system.« less
The cost and distribution of firefighter injuries in a large Canadian Fire Department.
Frost, D M; Beach, T A C; Crosby, I; McGill, S M
2016-11-22
There is limited data available regarding the cost of firefighter injuries. This information is necessary to develop targeted injury prevention strategies. To categorize the cost of injuries filed in 2012 by firefighters from a from a large department by job duty, injury type, body part affected, and the general motion pattern employed at the time of injury. Data were taken from reports filed by CFD personnel and claims filed with the Workers' Compensation Board (WCB) of Alberta between January 1, 2012 and December 31, 2012. Of the 244 injuries reported, 65% were categorized as sprains and strains, the most frequent of which affected the back (32%). The total cost of all claims was $555,955; 77% were sprain/strain-related. Knee and back injuries were most costly ($157,383 and $100,459). Categorized by job duty, most sprains/strains (31%) were sustained while attending to fire station responsibilities, although physical training was associated with the highest costs (34%). Fireground operations were attributed to 18% of sprains/strains and 16% of costs. Lifting injuries were more frequent (23%) and costly (20%) than all injuries. The most common and costly injuries occurred while attending to fire station-related responsibilities and during physical training.
Aviation Maintenance Safety Articles, January/February 1990
1990-02-01
actually looked at the fast that you don’t know you’re response of the crew kept the deck-edge fire stations? Do tired or hurt. It wasn’t until fire...connector. Approx- tenance supervisors are caught up in administrative imately 2 inches of wire was added to the harness, tasks, and they fail to excercise ... fast -acting strain of dry rot attacked ear -ly preventable, the container within seven days prior to the accep- The proper routing for the arming cable
2009-07-11
Mike Suffredini, NASA Manager, International Space Station (ISS) Program, talks with other NASA mission managers in from Firing Room Four of the Launch Control Center at NASA's Kennedy Space Center in Cape Canaveral, Florida, Sunday, July 12, 2009. The space shuttle Endeavour is set to launch at 7:13p.m. EDT with the crew of STS-127 and start a 16-day mission that will feature five spacewalks and complete construction of the Japan Aerospace Exploration Agency's Kibo laboratory. Photo Credit: (NASA/Bill Ingalls)
2013-08-26
ISS036-E-037185 (26 Aug. 2013) --- One of the Expedition 36 crew members aboard the International Space Station used a 50mm lens to record this view of the massive drought-aided Rim Fire in and around California's Yosemite National Park and the Stanislaus National Forest on Aug. 26. The fire began on Aug. 17 and, at the time of this photo on Aug. 26, it still continues to burn, as some 3,700 firefighters battle it. More than 224 square miles have been affected.
2008-09-01
of up to 1000 individual boreholes is filled with 5000 to 10,000 lbs of material and delay fired over several seconds. The explosive array is...delay-fired mining events using seismic arrays : Application to the PDAR array in Wyoming, USA, Bull. Seism. Soc. Am. 97: pp .989–1001. Arrowsmith...regional seismic stations in monitoring areas of interest, particularly in countries where mining efforts are significant to the economy. As with other
NASA Technical Reports Server (NTRS)
Whitlock, Charles H.; Lecroy, Stuart R.; Rossow, William B.; Bell, Ken L.
1989-01-01
Maps and tables are presented which show 45 satellite derived physical, radiation, or cloud parameters from ISCCP CX tapes during the FIRE/SRB Wisconsin experiment region from October 14 through November 2, 1986. Pixel locations selected for presentation are for an area which coincided with a 100 x 100 km array of evenly spaced ground truth sites. Area-averaged parameters derived from the ISSCP data should be consistent with area averages from the groundtruth stations.
2006-06-23
KENNEDY SPACE CENTER, FLA. - NASA Test Director Ted Mosteller (center) briefs the media about Firing Room 4 (FR4), which has been undergoing renovations for two years. FR4 is now designated the primary firing room for all remaining shuttle launches, and will also be used daily to manage operations in the Orbiter Processing Facilities and for integrated processing for the shuttle. The firing room now includes sound-suppressing walls and floors, new humidity control, fire-suppression systems and consoles, support tables with computer stations, communication systems and laptop computer ports. FR 4 also has power and computer network connections and a newly improved Checkout, Control and Monitor Subsystem. The renovation is part of the Launch Processing System Extended Survivability Project that began in 2003. United Space Alliance's Launch Processing System directorate managed the FR 4 project for NASA. Photo credit: NASA/Dimitri Gerondidakis
2006-06-23
KENNEDY SPACE CENTER, FLA. - NASA Test Director Ted Mosteller (right) briefs the media about Firing Room 4 (FR4), which has been undergoing renovations for two years. FR4 is now designated the primary firing room for all remaining shuttle launches, and will also be used daily to manage operations in the Orbiter Processing Facilities and for integrated processing for the shuttle. The firing room now includes sound-suppressing walls and floors, new humidity control, fire-suppression systems and consoles, support tables with computer stations, communication systems and laptop computer ports. FR 4 also has power and computer network connections and a newly improved Checkout, Control and Monitor Subsystem. The renovation is part of the Launch Processing System Extended Survivability Project that began in 2003. United Space Alliance's Launch Processing System directorate managed the FR 4 project for NASA. Photo credit: NASA/Dimitri Gerondidakis
2006-06-23
KENNEDY SPACE CENTER, FLA. - Ted Mosteller (right), NASA test director, briefs the media about Firing Room 4 (FR4), which has been undergoing renovations for two years. FR4 is now designated the primary firing room for all remaining shuttle launches, and will also be used daily to manage operations in the Orbiter Processing Facilities and for integrated processing for the shuttle. The firing room now includes sound-suppressing walls and floors, new humidity control, fire-suppression systems and consoles, support tables with computer stations, communication systems and laptop computer ports. FR 4 also has power and computer network connections and a newly improved Checkout, Control and Monitor Subsystem. The renovation is part of the Launch Processing System Extended Survivability Project that began in 2003. United Space Alliance's Launch Processing System directorate managed the FR 4 project for NASA. Photo credit: NASA/Dimitri Gerondidakis
2010-12-03
CAPE CANAVERAL, Fla. -- The SpaceX Falcon 9 rocket static fire test on Space Launch Complex-40 at Cape Canaveral Air Force Station was aborted at T minus 1.1 seconds due to high engine chamber pressure. During the test, all nine Merlin engines, which use rocket-grade kerosene and liquid oxygen to produce 1 million pounds of thrust, are expected to fire at once. After the test, SpaceX will conduct a thorough review of all data as engineers make final preparations for the first launch of the Commercial Orbital Transportation Services (COTS) Dragon spacecraft to low Earth orbit atop the Falcon 9. This first stage firing is part of a full launch dress rehearsal, which will end after the engines fire at full power for two seconds, with only the hold-down system restraining the rocket from flight. Photo credit: NASA/Rusty Backer
2014-07-19
ISS040-E-070439 (19 July 2014) --- One of the Expedition 40 crew members aboard the Earth-orbiting International Space Station recorded this July 19 image of wildfires which are plaguing the Northwest and causing widespread destruction. The orbital outpost was flying 223 nautical miles above a point on Earth located at 48.0 degrees north latitude and 116.9 degrees west longitude when the image was exposed. The state of Washington is especially affected by the fires, many of which have been blamed on lightning. This particular fire was part of the Carlton Complex Fire, located near the city of Brewster in north central Washington. The reservoir visible near the center of the image is Banks Lake.
2012-06-27
ISS031-E-146397 (27 June 2012) --- An Expedition 31 crew member aboard the International Space Station, flying approximately 240 miles above Earth, recorded a series of images of the current wild fires in the western and southwestern United States. These particular fires, of unknown cause, are burning at the south end of the Wyoming Range in southwestern Wyoming, and have affected 17,000 acres. The fires have produced two major smoke plumes, seen at upper left of the 18mm frame. Winds transport the smoke in a northeasterly direction. Utah?s Great Salt Lake (center) is about 120 miles away. Bear Lake and Utah Lake (very light blue or gray) are also visible in the frame.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-27
... Monastery, 5700 N. Harlem Dr., Chicago, 13000048 Storkline Furniture Corporation Factory, 4400-4418 W. 26th St., Chicago, 13000049 MASSACHUSETTS Essex County North Street Fire Station, 142 North St., Salem...
Concentration and Transport of Carbon Monoxide from the California Wildfires
2009-09-04
Carbon monoxide in the smoke from the Station fire was lofted high into the atmosphere, where it was observed by JPL Atmospheric Infrared Sounder instrument onboard NASA Aqua satellite. Animation available at the Photojournal.
AmeriFlux US-Wrc Wind River Crane Site
Bible, Ken [University of Washington; Wharton, Sonia [Lawrence Livermore National Laboratory
2016-01-01
This is the AmeriFlux version of the carbon flux data for the site US-Wrc Wind River Crane Site. Site Description - Wind River Field Station flux tower site is located in the T.T. Munger Research Area of the Wind River Ranger District in the Gifford Pinchot National Forest. Protected since 1926, the T.T. Munger Research Natural Area (RNA) is administered by the USDA Forest Service Pacific Northwest Research Station and Gifford Pinchot National Forest. The Douglas-fir/western hemlock dominant stand is approximately 500 years old and represents end points of several ecological gradients including age, biomass, structural complexity, and density of the dominant overstory species. A complete stand replacement fire, approximately 450-500 years ago, resulted in the initial establishment. No significant disturbances have occurred since the fire aside from those confined to small groups of single trees, such as overturn from high wind activity and mechanical damage from winter precipitation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Becker, W.; Stalcup, T.; Schild, V.
1992-01-01
The Neil Simpson Unit is a 220,000 lb/hr pulverized coal boiler that was designed to fire a local Wyoming subbituminous coal. During the late 1980s, the Wyoming Department of Air Quality imposed emission limits on the Black Hills Power and Light Co., Neil Simpson Station. The new limits required Black Hills power to control not only particulate and sulfur dioxide (SO{sub 2}) emissions, but also nitrogen oxide (NO{sub x}) emissions. At the same time, Black Hills Power initiated an efficiency improvement study at Neil Simpson Station to investigate methods for reducing net electrical generation costs. This paper addresses the plantmore » efficiency and emissions studies, startup activities, the operating problems and successful operating solutions for NO{sub x} control when firing a Wyoming subbituminous coal. Also included is a summary of the post-0retrofit boiler performance data.« less
Observations of rapid-fire event tremor at Lascar volcano, Chile
Asch, Guenter; Wylegalla, K.; Hellweg, M.; Seidl, D.; Rademacher, H.
1996-01-01
During the Proyecto de Investigacio??n Sismolo??gica de la Cordillera Occidental (PISCO '94) in the Atacama desert of Northern Chile, a continuously recording broadband seismic station was installed to the NW of the currently active volcano, Lascar. For the month of April, 1994, an additional network of three, short period, three-component stations was deployed around the volcano to help discriminate its seismic signals from other local seismicity. During the deployment, the volcanic activity at Lascar appeared to be limited mainly to the emission of steam and SO2. Tremor from Lascar is a random, ??rapid-fire?? series of events with a wide range of amplitudes and a quasi-fractal structure. The tremor is generated by an ensemble of independent elementary sources clustered in the volcanic edifice. In the short-term, the excitation of the sources fluctuates strongly, while the long-term power spectrum is very stationary.
Operation and Development Status of the Spacecraft Fire Experiments (Saffire)
NASA Technical Reports Server (NTRS)
Ruff, Gary A.; Urban, David L.
2016-01-01
Since 2012, a series of Spacecraft Fire Experiments (Saffire) have been under development by the Spacecraft Fire Safety Demonstration (SFS Demo) project, funded by NASA's Advanced Exploration Systems Division. The overall objective of this project is to reduce the uncertainty and risk associated with the design of spacecraft fire safety systems for NASA's exploration missions. The approach to achieving this goal has been to define, develop, and conduct experiments that address gaps in spacecraft fire safety knowledge and capabilities identified by NASA's Fire Safety System Maturation Team. The Spacecraft Fire Experiments (Saffire-I, -II, and -III) are material flammability tests at length scales that are realistic for a spacecraft fire in low-gravity. The specific objectives of these three experiments are to (1) determine how rapidly a large scale fire grows in low-gravity and (2) investigate the low-g flammability limits compared to those obtained in NASA's normal gravity material flammability screening test. The experiments will be conducted in Orbital ATK's Cygnus vehicle after it has unberthed from the International Space Station. The tests will be fully automated with the data downlinked at the conclusion of the test before the Cygnus vehicle reenters the atmosphere. This paper discusses the status of the Saffire-I, II, and III experiments followed by a review of the fire safety technology gaps that are driving the development of objectives for the next series of experiments, Saffire-IV, V, and VI.
Automation of closed environments in space for human comfort and safety
NASA Technical Reports Server (NTRS)
1990-01-01
The Environmental Control and Life Support System (ECLSS) for the Space Station Freedom and future colonization of the Moon and Mars presents new challenges for present technologies. Current plans call for a crew of 8 to live in a safe, shirt-sleeve environment for 90 days without ground support. Because of these requirements, all life support systems must be self-sufficient and reliable. The ECLSS is composed of six subsystems. The temperature and humidity control (THC) subsystem maintains the cabin temperature and humidity at a comfortable level. The atmosphere control and supply (ACS) subsystem insures proper cabin pressure and partial pressures of oxygen and nitrogen. To protect the space station from fire damage, the fire detection and suppression (FDS) subsystem provides fire sensing alarms and extinguishers. The waste management (WM) subsystem compacts solid wastes for return to Earth, and collects urine for water recovery. Because it is impractical, if not impossible, to supply the station with enough fresh air and water for the duration of the space station's extended mission, these elements are recycled. The atmosphere revitalization (AR) subsystem removes CO2 and other dangerous contaminants from the air. The water recovery and management (WRM) subsystem collects and filters condensate from the cabin to replenish potable water supplies, and processes urine and other waste waters to replenish hygiene water supplies. These subsystems are not fully automated at this time. Furthermore, the control of these subsystems is not presently integrated; they are largely independent of one another. A fully integrated and automated ECLSS would increase astronauts' productivity and contribute to their safety and comfort. The Kansas State University Advanced Design Team is in the process of researching and designing controls for the automation of the ECLSS for Space Station Freedom and beyond. The approach chosen to solve this problem is to divide the design into three phases. The first phase is to research the ECLSS as a whole system and then concentrate efforts on the automation of a single subsystem. The AR subsystem was chosen for our focus. During the second phase, the system control process will then be applied to the AR subsystem.
Biomass power for rural development. Technical progress report, July 1--September 30, 1997
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neuhauser, E.
The focus of the DOE/USDA sponsored biomass power for rural development project is to develop commercial energy crops for power generation by the year 2000. The New York based Salix Consortium project is a multi-partner endeavor, implemented in three stages. Phase-1, Final Design and Project Development, will conclude with the preparation of construction and/or operating permits, feedstock production plans, and contracts ready for signature. Field trials of willow (Salix) have been initiated at several locations in New York (Tully, Lockport, King Ferry, La Fayette, Massena, and Himrod) and co-firing tests are underway at Greenidge Station (NYSEG) and Dunkirk Station (NMPC).more » Phase-2 of the project will focus on scale-up of willow crop acreage, construction of co-firing facilities at Dunkirk Station (NMPC), and final modifications for Greenidge Station. Cofiring willow is also under consideration for GPU`s Seward Station where testing is underway. There will be an evaluation of the energy crop as part of the gasification trials occurring at BED`s McNeill power station. Phase-3 will represent fullscale commercialization of the energy crop and power generation on a sustainable basis. During the third quarter of 1997, much of the Consortium`s effort has focused on outreach activities, continued feedstock development, fuel supply planning, and fuel contract development, and preparation for 1998 scale-up activities. The Consortium also submitted a Phase-1 extension proposal during this period. A few of the more important milestones are outlined below. The fourth quarter of 1997 is expected to be dominated by Phase-II proposal efforts and planning for 1998 activities.« less
2000-10-11
KENNEDY SPACE CENTER, Fla. -- Space Shuttle Discovery roars through the sky trailing fire and blue mach diamonds from the engines. The perfect on-time liftoff at 7:17 p.m. EDT sends a crew of seven on a construction flight to the International Space Station on mission STS-92, the 100th in the history of the Shuttle program. Discovery also carries a payload that includes the Integrated Truss Structure Z-1, first of 10 trusses that will form the backbone of the Space Station, and the third Pressurized Mating Adapter that will provide a Shuttle docking port for solar array installation on the sixth Station flight and Lab installation on the seventh Station flight. Discovery’s landing is expected Oct. 22 at 2:10 p.m. EDT
2000-10-11
KENNEDY SPACE CENTER, Fla. -- Space Shuttle Discovery roars through the sky trailing fire and blue mach diamonds from the engines. The perfect on-time liftoff at 7:17 p.m. EDT sends a crew of seven on a construction flight to the International Space Station on mission STS-92, the 100th in the history of the Shuttle program. Discovery also carries a payload that includes the Integrated Truss Structure Z-1, first of 10 trusses that will form the backbone of the Space Station, and the third Pressurized Mating Adapter that will provide a Shuttle docking port for solar array installation on the sixth Station flight and Lab installation on the seventh Station flight. Discovery’s landing is expected Oct. 22 at 2:10 p.m. EDT
Measurements of nitrous oxide emissions from P.F. fired power stations
NASA Astrophysics Data System (ADS)
Sloan, S. A.; Laird, C. K.
Nitrous oxide (N 2O) was measured in the flue gas from four wall-fired and three corner-fired 500 MW boilers, fitted with either conventional or low-NO x burners, at four C.E.G.B. power stations. Measurements were made both by on-line non-dispersive infra red (NDIR) monitors and by extractive sampling for later laboratory analysis by electron capture gas chromatography (ECD GC). It was found that the on-line and laboratory methods were in good agreement for samples analyzed within 1-3 h of sampling, but that the nitrous oxide concentration in the stored samples had a tendency to increase with time, which was dependent on the concentration of water in the sample. Experiments with synthetic mixtures showed that the increase in nitrous oxide concentration was consistent with the overall reaction2NO+SO 2→N 2O+SO 3 in which nitric oxide is reduced by sulphur dioxide. The highest average N 2O concentration measured by the on-line analyzer was 16 vpm, and for most of the boilers monitored the concentration was less than 10 vpm. There was no statistically significant difference between the measured N 2O emissions from normal boilers and those fitted with low-NO x burners. It is suggested that these values are close to the true levels of N 2O emissions from p.f. fired boilers and that recent reports of high levels (up to 200 vpm) are likely to be an artefact resulting from the observed generation of N 2O in stored samples. A consequence of these measurements of N 2O is that current estimates of the contribution of emissions from p.f. fired boilers to the global N 2O budget are likely to be too high.
NASA Technical Reports Server (NTRS)
Busch, Arthur M.; Campbell, John A.
1959-01-01
A crash-fire protection system to suppress the ignition of crash-spilled fuel that may be ingested by a T-56 turbopropeller engine is described. This system includes means for rapidly extinguishing the combustor flame and means for cooling and inerting with water the hot engine parts likely to ignite engine-ingested fuel. Combustion-chamber flames were extinguished in 0.07 second at the engine fuel manifold. Hot engine parts were inerted and cooled by 52 pounds of water discharged at ten engine stations. Performance trials of the crash-fire prevention system were conducted by bringing the engine up to takeoff temperature, stopping the normal fuel flow to the engine, starting the water discharge, and then spraying fuel into the engine to simulate crash-ingested fuel. No fires occurred during these trials, although fuel was sprayed into the engine from 0.3 second to 15 minutes after actuating the crash-fire protection system.
NASA Technical Reports Server (NTRS)
Clancy, Daniel J.; Oezguener, Uemit; Graham, Ronald E.
1994-01-01
The potential for excessive plume impingement loads on Space Station Freedom solar arrays, caused by jet firings from an approaching Space Shuttle, is addressed. An artificial neural network is designed to determine commanded solar array beta gimbal angle for minimum plume loads. The commanded angle would be determined dynamically. The network design proposed involves radial basis functions as activation functions. Design, development, and simulation of this network design are discussed.
Earth Observations taken by the Expedition 31 Crew
2012-06-02
ISS031-E-84006 (2 June 2012) --- This digital image from the Expedition 31 crew aboard the International Space Station is one of a series from a mounted, automated, and nighttime session of a still camera when viewed in sequence shows the flame-ring associated with wild fires in the Southwest slip by in the upper right while the lights of the El Paso-Las Cruces rise from bottom center. A Russian spacecraft is docked to the station