1995-01-01
FURTHER ACTION DECISION UNDER CERCLAI STUDY AREA 31 MOORE ARMY AIRFIELD FIRE FIGHTING TRAINING AREA FORT DEVENS , MASSACHUSETFS TABLE OF CONTENTS jSection...Inc. 31DD.DOC 6917.11 111,, NO FURTHER ACTION DECISION UNDER CERCLA I STUDY AREA 31 MOORE ARMY AIRFIELD FIRE FIGHTING TRAINING AREA 3 FORT DEVENS ...Fire Fighting Training Area) at Fort Devens , Massachusetts, have resulted in the decision that no further studies or remediation are required at this
Installation Restoration Program. Phase 1. Records Search, Kelly AFB, Texas
1982-02-01
1000-1500 gallons per year based on two training sessions per year. The ultimate BOD of AFFF ( FC -780B, manufactured by 3M) is 370,000 mg/l in...Landfill 1917-1942 44 24 FC -i Fire Control Training Area ?-1950’s 42 25 FC -2 Fire Control Training Area 1950’s-1981 41 26 RD-i Radioactive Disposal Area...were buried had very short half-lifes. This site received a low score of 45. 6) Fire Control Training Areas a. The Fire Control Training Areas FC -I and
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nacht, S.
1999-08-01
The Mercury Fire Training Pit is a former fire training area located in Area 23 of the Nevada Test Site (NTS). The Mercury Fire Training Pit was used from approximately 1965 to the early 1990s to train fire-fighting personnel at the NTS, and encompasses an area approximately 107 meters (m) (350 feet [ft]) by 137 m (450 ft). The Mercury Fire Training Pit formerly included a bermed burn pit with four small burn tanks, four large above ground storage tanks an overturned bus, a telephone pole storage area, and areas for burning sheds, pallets, and cables. Closure activities will includemore » excavation of the impacted soil in the aboveground storage tank and burn pit areas to a depth of 1.5 m (5 ft), and excavation of the impacted surface soil downgradient of the former ASTs and burnpit areas to a depth of 0.3 m (1 ft). Excavated soil will be disposed in the Area 6 Hydrocarbon Landfill at the NTS.« less
14 CFR 139.321 - Handling and storing of hazardous substances and materials.
Code of Federal Regulations, 2014 CFR
2014-01-01
...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...
14 CFR 139.321 - Handling and storing of hazardous substances and materials.
Code of Federal Regulations, 2011 CFR
2011-01-01
...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...
14 CFR 139.321 - Handling and storing of hazardous substances and materials.
Code of Federal Regulations, 2010 CFR
2010-01-01
...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...
14 CFR 139.321 - Handling and storing of hazardous substances and materials.
Code of Federal Regulations, 2013 CFR
2013-01-01
...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...
14 CFR 139.321 - Handling and storing of hazardous substances and materials.
Code of Federal Regulations, 2012 CFR
2012-01-01
...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...
Establishing Fire Safety Skills Using Behavioral Skills Training
ERIC Educational Resources Information Center
Houvouras, Andrew J., IV; Harvey, Mark T.
2014-01-01
The use of behavioral skills training (BST) to educate 3 adolescent boys on the risks of lighters and fire setting was evaluated using in situ assessment in a school setting. Two participants had a history of fire setting. After training, all participants adhered to established rules: (a) avoid a deactivated lighter, (b) leave the training area,…
2016-08-01
ER D C TR -1 6- 1 Integrated Climate Assessment for Army Enterprise Planning Effects of Climate Change and Urban Development on Army...ERDC TR-16-1 January 2016 Effects of Climate Change and Urban Development on Army Training Capabilities Firing Ranges and Maneuver Areas Michelle E... changes associated with climate and urban development might affect the ability of Army installa- tions to continue to conduct training on firing ranges
Todd E. Bruce
1995-01-01
Fire agencies throughout the San Francisco Bay Area formed a grassroots organization to influence a firesafe environment. The Bay Area Wildfire Forum (BAWF) was organized in 1992 to coordinate wildland fire training while promoting and encouraging further activities regarding wildland firefighting and fire prevention.
Your Fire Department. Organization--Recruitment--Equipment--Training. Revised.
ERIC Educational Resources Information Center
Pribyl, Paul F.
This publication is intended as a guide in the organization, staffing, equipping, and training of fire departments in Wisconsin. A separate section focuses on each of these four areas. The first section discusses an ordinance to create a fire department, qualifications and authority of the fire chief, and an outline of duties and responsibilities…
Fire Safety of Passenger Trains: A Review of U.S. and Foreign Approaches
DOT National Transportation Integrated Search
1993-12-01
could develop into potentially life-threatening events. Fire safety is an area of particular interest for both : conventional intercity and commuter trains, as well as new alternative high-speed train technologies. These : technologies include steel-...
U.S. Coast Guard cutter personnel on Sweetbriar train their fire ...
U.S. Coast Guard cutter personnel on Sweetbriar train their fire hoses on a burning pleasure boat in an Alaskan harbor. A U.S. Coast Guard rigid-hull inflatable helps with the fire-fighting effort - U.S. Coast Guard Cutter SWEETBRIER, Cordova, Valdez-Cordova Census Area, AK
Removal of Invasive Fire-Prone Grasses to Increase Training Lands in the Pacific
2008-09-01
Boone Kauffman. U.S. Forest Service. Pacific Northwest Research Center. Hilo . Hawaii . SWCA, Inc. 39 SWCA also acknowledges Amy Brown Curtis...Marine Corps Base Hawaii (MCBH), Marine Corps Training Area Bellows (MCTAB), Army installations Makua Valley, Schofield Barracks, Pohakuloa Training...Area, the Hawaii Army National Guard facility at Diamond Head Crater, and at the Naval Magazine on the Island of Guam. Invasive, fire-prone
Moody, Cheryl A; Hebert, Gretchen N; Strauss, Steven H; Field, Jennifer A
2003-04-01
Various formulations of fire-extinguishing materials, including aqueous film-forming foams (AFFFs), were used as part of fire-training exercises conducted at Wurtsmith Air Force Base (WAFB) in northeastern Michigan from the 1950s until the base was decommissioned in 1993. As a result of past fire-training exercises, AFFF-laden wastewater containing fuels, solvents, and other materials directly entered groundwater without prior treatment. Perfluorinated surfactants are key components in some AFFF formulations. In this study, groundwater was analyzed for perfluoroalkanesulfonates and perfluorocarboxylates. Perfluoroalkanesulfonates were directly detected using negative-ion electrospray ionization mass spectrometry. Derivatized perfluorocarboxylates were detected using electron impact gas chromatography-mass spectrometry. Groundwater from wells around fire-training area FTA-02 at WAFB contained four perfluorinated surfactants ranging in concentration from 3 to 120 microg L(-1): perfluorooctanesulfonate (PFOS); perfluorohexanesulfonate; perfluorooctanoate; and perfluorohexanoate. This is the first report demonstrating that PFOS, recently shown to be toxic to organisms ranging from zooplankton to primates, is still present in groundwater in measurable quantities five or more years after its last known use.
Eva K. Strand; Kathy H. Schon; Jeff Jones
2010-01-01
Technological advances in the area of fuel and wildland fire management have created a need for effective decision support tools and technology training. The National Interagency Fuels Committee and LANDFIRE have chartered a team to develop science-based learning tools for assessment of fire and fuels and to provide online training and technology transfer to help...
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
Preliminary Assessment/Site Inspection Report of Areas Of concern (AOC) A thru F at WK Kellogg, Battle Creek, MI. A Preliminary Assessment/Site Inspection was performed on 6 AOC`s at WK Kellogg to confirm or deny the presence of contamination a the AOC`s. The AOC`s involved in this investigation include. AOC A, Waste Accumulation Area; AOC B, Motor Pool Drainage Ditch; AOC C, Fire Training Area South; AOC D, Fire Training Area West; AOC E, Old Hanger (Building 6900); AOC F, New Hanger (Building 6901). The recommendation is for AOC`s A and B continue to the RI/FS stage.
Effects of military training activities on shrub-steppe raptors in southwestern Idaho, USA
Lehman, Robert N.; Steenhof, Karen; Kochert, Michael N.; Carpenter, L.B.
1999-01-01
Between 1991 and 1994, we assessed relative abundance, nesting success, and distribution of ferruginous hawks (Buteo regalis), northern harriers (Circus cyaneus), burrowing owls (Athene cunicularia), and short-eared owls (Asio flammeus) inside and outside a military training site in the Snake River Birds of Prey National Conservation Area, southwestern Idaho. The Orchard Training Area is used primarily for armored vehicle training and artillery firing by the Idaho Army National Guard. Relative abundance of nesting pairs inside and outside the training site was not significantly different from 1991 to 1993 but was significantly higher on the training site in 1994 (Pa??a??a??0.03). Nesting success varied among years but was not significantly different inside and outside the training site (Pa??>a??0.26). In 1994, short-eared owl and burrowing owl nests were significantly closer to firing ranges used early in the spring before owls laid eggs than were random points (Pa??
DOE Office of Scientific and Technical Information (OSTI.GOV)
C. M. Obi
2000-04-01
The purpose of this Closure Report (CR) is to provide documentation of the completed corrective action and to provide data confirming the corrective action. The corrective action was performed following the approved Corrective Action Plan (CAP) (U.S. Department of Energy [DOE], 1999b) and consisted of closure-in-place with partial excavation, disposal, backfilling, administrative controls, and post-closure monitoring. Soil with petroleum hydrocarbon concentrations above the Nevada Division of Environmental Protection (NDEP) Action Level of 100 milligrams per kilogram (mg/kg) (Nevada Administrative Code, 1996) was removed to a depth of 1.5 meters (m) (5 feet [ft]). The excavations were backfilled with clean fillmore » to restore the site and to prevent contact with deeper, closed-in-place soil that exceeded the NDEP Action Level. According to the Corrective Action Investigation Plan (CAIP) (DOE, 1998), the Mercury Fire Training Pit was used from approximately 1965 to the early 1990s to train fire-fighting and emergency response personnel at the NTS and encompasses an area approximately 85 by 115 m (280 by 380 ft). The location of the Mercury Fire Training Pit is shown in Figure 1 and a site plan is shown in Figure 2. The Mercury Fire Training Pit formerly included a bermed bum pit with four small bum tanks; four large above ground storage tanks (ASTS); an overturned bus, a telephone pole storage area; and several areas for burning sheds, pallets, and cables. During the active life of the Mercury Fire Training Pit, training events were conducted at least monthly and sometimes as often as weekly. Fuels burned during these events included off-specification or rust-contaminated gasoline, diesel, and aviation fuel (JP-4). Other items burned during these events included paint, tires, a pond liner, wood, paper, cloth, and copper cable. Approximately 570 liters (L) (150 gallons [gal]) of fuel were used for each training event resulting in an approximate total of 136,000 L (36,000 gal) of fuel used over the life of the Mercury Fire Training Pit. Unburned fuel was allowed to pool on the ground and was left to eventually volatilize or soak into the soil. In addition, fuels from the ASTS and fuels and fluids from the overturned bus leaked or spilled onto the ground. Approximately 19 L to 38 L (5 to 10 gal) of paint were also burned monthly until sometime in the 1970s.« less
ERIC Educational Resources Information Center
Kloss, Frank E.
The report briefly describes a project whose purpose was to provide guidance and training for rural volunteer fire chiefs and firefighters in Wisconsin to increase the knowledge and skills they use to protect lives and property. The training was provided by part-time instructors who taught and demonstrated the courses and curriculum to suit the…
Communicating with wildland interface communities during wildfire
Taylor, Jonathan G.; Gillette, Shana C.
2005-01-01
Communications during fire events are complex. Nevertheless, training fire information officers to plan fire communications before events, and to communicate during fires in a way that accurately and promptly informs residents in fire-affected areas, can increase effectiveness, reduce anxiety, ensure residents have accurate information on which to act, help them make better decisions, and possibly save lives.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1992-06-16
The 7-acre Mountain Home Air Force Base (AFB) site was a fire department training area located in Mountain Home, Elmore County, Idaho. From 1962 to 1975, the Mountain Home Air Force Base used the site for fire department training exercises. Each exercise began by saturating the bermed training area with water, followed directly by applying 250 to 500 gallons of fuel. The flames were extinguished with Aqueous Film Forming Foam (AFFF), or prior to 1972, with a water-based protein foam. The training session was completed with a post-exercise ignition of the residual fuel in a bermed area. The USAF investigationsmore » identified solvents and petroleum, oil, lubricant (POL) wastes in the soil. Under the Installation Restoration Program (IRP), the USAF conducted a record search, drilling, and sampling of soil borings to bedrock, the installation of monitoring wells, and hand auger samples. The ROD provided a final remedy for onsite soil as OU4. Because contaminants were found at such low concentrations, the soil was covered by crushed asphalt and has little potential to impact ecological receptors. The soil posed low risks for humans at the site and no remediation was necessary.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cantrell, Kirk J; Liikala, Terry L; Strenge, Dennis L
PNNL conducted independent site evaluations for four sites at Fort Lewis, Washington, to determine their suitability for closure on behalf of the installation. These sites were recommended for ''No Further Action'' by previous investigators and included the Storm Water Outfalls/Industrial Waste Water Treatment Plant (IWTP), the Pesticide Rinse Area, the Old Fire Fighting Training Pit, and the Illicit PCB Dump Site.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cantrell, Kirk J.; Liikala, Terry L.; Strenge, Dennis L.
PNNL conducted independent site evaluations for four sites at Fort Lewis, Washington, to determine their suitability for closure on behalf of the installation. These sites were recommended for "No Further Action" by previous invesitgators and included the Storm Water Outfalls/Industrial Waste Water Treatment Plant (IWTP), the Pesticide Rinse Area, the Old Fire Fighting Training Pit, and the Illicit PCB Dump Site.
Prevention and suppression of metal packing fires.
Roberts, Mark; Rogers, William J; Sam Mannan, M; Ostrowski, Scott W
2003-11-14
Structured packing has been widely used because of large surface area that makes possible columns with high capacity and efficiency. The large surface area also contributes to fire hazards because of hydrocarbon deposits that can easily combust and promote combustion of the thin metal packing materials. Materials of high surface area that can fuel fires include reactive metals, such as titanium, and materials that are not considered combustible, such as stainless steel. Column design and material selection for packing construction is discussed together with employee training and practices for safe column maintenance and operations. Presented also are methods and agents for suppression of metal fires. Guidance for prevention and suppression of metal fires is related to incidents involving packing fires in columns.
2016-02-01
forecasting the risk of munitions constituents (MC), such as high explosives and metals , that leave firing and training ranges and contaminate the...quality terrestrial natural infrastructure exist down- range of small arms training ranges on Department of Defense (DoD) in- stallations. Live- fire ...CERL TN-16-1 iv Illustrations Figures A-1 Initial horizontal trajectory of a tracer bullet fired at a 600 m target at the Malone 5 range on Fort
Estimation of fire danger in Hawai'i using limited weather data and simulation
D.R. Weise; S.L. Stephens; F.M. Fujioka; T.J. Moody; J. Benoit
2010-01-01
The presence of fire in Hawai'i has increased with introduction of nonnative grasses. Fire danger estimation using the National Fire Danger Rating System (NFDRS) typically requires 5 to 10 yr of data to determine percentile weather values and fire activity. The U.S. Army Pōhakuloa Training Area in Hawaiâi is located in the interface zone between windward...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-19
... (paperwork) requirements. In general, the Standard requires employers to develop a written fire safety plan... of the details of the fire safety plan and that employees have been trained as required by the... to post the fire safety plan or to place it in an area accessible to employees to 12 hours for firms...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-26
... Construction and Operation of an Infantry Platoon Battle Course at P[omacr]hakuloa Training Area, Hawai`i... requirements at P[omacr]hakuloa Training Area (PTA), Hawai`i. The proposed IPBC would support the live- fire... Western Range Area Alternative (preferred) and the Charlie Circle Alternative. Both proposed IPBC...
Miller, J.D.; Knapp, E.E.; Key, C.H.; Skinner, C.N.; Isbell, C.J.; Creasy, R.M.; Sherlock, J.W.
2009-01-01
Multispectral satellite data have become a common tool used in the mapping of wildland fire effects. Fire severity, defined as the degree to which a site has been altered, is often the variable mapped. The Normalized Burn Ratio (NBR) used in an absolute difference change detection protocol (dNBR), has become the remote sensing method of choice for US Federal land management agencies to map fire severity due to wildland fire. However, absolute differenced vegetation indices are correlated to the pre-fire chlorophyll content of the vegetation occurring within the fire perimeter. Normalizing dNBR to produce a relativized dNBR (RdNBR) removes the biasing effect of the pre-fire condition. Employing RdNBR hypothetically allows creating categorical classifications using the same thresholds for fires occurring in similar vegetation types without acquiring additional calibration field data on each fire. In this paper we tested this hypothesis by developing thresholds on random training datasets, and then comparing accuracies for (1) fires that occurred within the same geographic region as the training dataset and in similar vegetation, and (2) fires from a different geographic region that is climatically and floristically similar to the training dataset region but supports more complex vegetation structure. We additionally compared map accuracies for three measures of fire severity: the composite burn index (CBI), percent change in tree canopy cover, and percent change in tree basal area. User's and producer's accuracies were highest for the most severe categories, ranging from 70.7% to 89.1%. Accuracies of the moderate fire severity category for measures describing effects only to trees (percent change in canopy cover and basal area) indicated that the classifications were generally not much better than random. Accuracies of the moderate category for the CBI classifications were somewhat better, averaging in the 50%-60% range. These results underscore the difficulty in isolating fire effects to individual vegetation strata when fire effects are mixed. We conclude that the models presented here and in Miller and Thode ([Miller, J.D. & Thode, A.E., (2007). Quantifying burn severity in a heterogeneous landscape with a relative version of the delta Normalized Burn Ratio (dNBR). Remote Sensing of Environment, 109, 66-80.]) can produce fire severity classifications (using either CBI, or percent change in canopy cover or basal area) that are of similar accuracy in fires not used in the original calibration process, at least in conifer dominated vegetation types in Mediterranean-climate California.
Chaos-induced modulation of reliability boosts output firing rate in downstream cortical areas.
Tiesinga, P H E
2004-03-01
The reproducibility of neural spike train responses to an identical stimulus across different presentations (trials) has been studied extensively. Reliability, the degree of reproducibility of spike trains, was found to depend in part on the amplitude and frequency content of the stimulus [J. Hunter and J. Milton, J. Neurophysiol. 90, 387 (2003)]. The responses across different trials can sometimes be interpreted as the response of an ensemble of similar neurons to a single stimulus presentation. How does the reliability of the activity of neural ensembles affect information transmission between different cortical areas? We studied a model neural system consisting of two ensembles of neurons with Hodgkin-Huxley-type channels. The first ensemble was driven by an injected sinusoidal current that oscillated in the gamma-frequency range (40 Hz) and its output spike trains in turn drove the second ensemble by fast excitatory synaptic potentials with short term depression. We determined the relationship between the reliability of the first ensemble and the response of the second ensemble. In our paradigm the neurons in the first ensemble were initially in a chaotic state with unreliable and imprecise spike trains. The neurons became entrained to the oscillation and responded reliably when the stimulus power was increased by less than 10%. The firing rate of the first ensemble increased by 30%, whereas that of the second ensemble could increase by an order of magnitude. We also determined the response of the second ensemble when its input spike trains, which had non-Poisson statistics, were replaced by an equivalent ensemble of Poisson spike trains. The resulting output spike trains were significantly different from the original response, as assessed by the metric introduced by Victor and Purpura [J. Neurophysiol. 76, 1310 (1996)]. These results are a proof of principle that weak temporal modulations in the power of gamma-frequency oscillations in a given cortical area can strongly affect firing rate responses downstream by way of reliability in spite of rather modest changes in firing rate in the originating area.
Heather Heward; Kathy H. Schon
2009-01-01
As technology continues to evolve in the area of fuel and wildland fire management so does the need to have effective tools and training on these technologies. The National Interagency Fuels Coordination Group has chartered a team of professionals to coordinate, develop, and transfer consistent, efficient, science-based fuel and fire ecology assessment GIS tools and...
30 CFR 77.1100 - Fire protection; training and organization.
Code of Federal Regulations, 2010 CFR
2010-07-01
....1100 Section 77.1100 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF... facilities and equipment shall be provided commensurate with the potential fire hazards at each structure...
1992-12-01
warfare ? • How does one develop training exercises to exploit this medium? • What are some of the implications for institutional training? The DARPA...IDT Inactive Duty Training JEW IIntelligencel•ectronic Warfare I FOR Intelligent Forces IPB Intelligence Preparation of the Battlefield JAAT Joint Air... Chemical xiI NFA No Fire Area NGB Nationhl Guard Bureau NTC National Training Center OAC Officers Advanced Cours- OC Observer/Controllcr OCI Observer
Teaching Health and Safety: Preparing Staff for the Unexpected.
ERIC Educational Resources Information Center
Cronin, Greg
1999-01-01
Discusses methods for training camp counselors in safety standards. Safety awareness and camp wellness should be introduced during staff interviews. During precamp training, staff should complete a test in OSHA requirements, followed by role playing to expand staff's knowledge in each OSHA safety and health area. First aid training, fire safety,…
Fire Extinguisher Training for Fire Watch and Designated Workers, Course 9893
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, Jimmy D.
At Los Alamos National Laboratory (LANL), all workers must be aware of LANL fire protection policies and be trained on what to do in the event of a fire. This course, Fire Extinguisher Training for Fire Watch and Designated Workers (#9893), provides awareness-level and hands-on training for fire watch personnel and designated workers. Fire watch personnel and designated workers are appointed by line management and must receive both awareness-level training and hands-on training in the use of portable fire extinguishers to extinguish an incipient-stage fire. This training meets the requirements of the Occupational Safety and Health Administration (OSHA) Code ofmore » Federal Regulations (CFR) 29 CFR 1910.157, Portable Fire Extinguishers, and Procedure (P) 101-26, Welding, Cutting, and Other Spark-/Flame-Producing Operations.« less
Fire service and first responder thermal imaging camera (TIC) advances and standards
NASA Astrophysics Data System (ADS)
Konsin, Lawrence S.; Nixdorff, Stuart
2007-04-01
Fire Service and First Responder Thermal Imaging Camera (TIC) applications are growing, saving lives and preventing injury and property damage. Firefighters face a wide range of serious hazards. TICs help mitigate the risks by protecting Firefighters and preventing injury, while reducing time spent fighting the fire and resources needed to do so. Most fire safety equipment is covered by performance standards. Fire TICs, however, are not covered by such standards and are also subject to inadequate operational performance and insufficient user training. Meanwhile, advancements in Fire TICs and lower costs are driving product demand. The need for a Fire TIC Standard was spurred in late 2004 through a Government sponsored Workshop where experts from the First Responder community, component manufacturers, firefighter training, and those doing research on TICs discussed strategies, technologies, procedures, best practices and R&D that could improve Fire TICs. The workshop identified pressing image quality, performance metrics, and standards issues. Durability and ruggedness metrics and standard testing methods were also seen as important, as was TIC training and certification of end-users. A progress report on several efforts in these areas and their impact on the IR sensor industry will be given. This paper is a follow up to the SPIE Orlando 2004 paper on Fire TIC usage (entitled Emergency Responders' Critical Infrared) which explored the technological development of this IR industry segment from the viewpoint of the end user, in light of the studies and reports that had established TICs as a mission critical tool for firefighters.
2006-04-01
06-9 ABSTRACT The gopher tortoise (Gopherus polyphemus) is a terrestrial reptile that was once quite plentiful throughout the Southeastern...Gopherus polyphemus) is a terrestrial reptile that was once quite plentiful throughout the Southeastern United States from South Carolina into...foraging, nesting, thermoregulation , etc., they are less likely to move into training areas. b) If prescribed fire is to be used to restore shrub
DOE Office of Scientific and Technical Information (OSTI.GOV)
Whitten, C.B.; Miller, S.P.; Derryberry, N.A.
1992-12-01
In 1986, the US Environmental Protection Agency (EPA) issued a Hazardous Waste Management Permit to Aberdeen Proving Ground (APG), Maryland. The permit required a Resource Conservation and Recovery Act (RCRA) Facility Assessment (RFA) of sites in the Aberdeen Area (AA) of APG. Recommendations from a draft RFA report suggested further investigations at the Fire Training Area (FTA). This study is in response to the recommendations. Three soil borings and twelve groundwater monitor wells were installed. Three rounds of groundwater sampling and analyses were conducted. APG lies in the Coastal Plain Physiographic Province which is underlain by sediments consisting of threemore » major units, the Potomac Group, the Talbot Formation, and Recent (Holocene) sediments. The Lower Cretaceous sediments of the Potomac Group lie unconformably on the older Precambrian rocks. In the early 1960's fire training was initiated and training has been conducted as often as once a week. Trenches were ignited after being filled with oil and water. The exercises concluded in 1989. During the RFA shallow boring soil gas surveys were conducted for volatile organic compound (VOC) contamination at the FTA. Deeper borings were conducted for monitor wells and geologic mapping. Sampling and monitoring of groundwater, surface water, and soils was conducted. Analyses of groundwater from the monitor wells and two supply wells indicate the AFTA is contributing chemical contaminants to the upper aquifer, which is at a depth of approximately 30 feet below ground surface. ....Aberdeen Proving Ground, Maryland, Hydrogeology, Groundwater, Site characterization, Groundwater contamination.« less
Quantifying post-fire fallen trees using multi-temporal lidar
NASA Astrophysics Data System (ADS)
Bohlin, Inka; Olsson, Håkan; Bohlin, Jonas; Granström, Anders
2017-12-01
Massive tree-felling due to root damage is a common fire effect on burnt areas in Scandinavia, but has so far not been analyzed in detail. Here we explore if pre- and post-fire lidar data can be used to estimate the proportion of fallen trees. The study was carried out within a large (14,000 ha) area in central Sweden burnt in August 2014, where we had access to airborne lidar data from both 2011 and 2015. Three data-sets of predictor variables were tested: POST (post-fire lidar metrics), DIF (difference between post- and pre-fire lidar metrics) and combination of those two (POST_DIF). Fractional logistic regression was used to predict the proportion of fallen trees. Training data consisted of 61 plots, where the number of fallen and standing trees was calculated both in the field and with interpretation of drone images. The accuracy of the best model was tested based on 100 randomly selected validation plots with a size of 25 × 25 m. Our results showed that multi-temporal lidar together with field-collected training data can be used for quantifying post-fire tree felling over large areas. Several height-, density- and intensity metrics correlated with the proportion of fallen trees. The best model combined metrics from both datasets (POST_DIF), resulting in a RMSE of 0.11. Results were slightly poorer in the validation plots with RMSE of 0.18 using pixel size of 12.5 m and RMSE of 0.15 using pixel size of 6.25 m. Our model performed least well for stands that had been exposed to high-intensity crown fire. This was likely due to the low amount of echoes from the standing black tree skeletons. Wall-to-wall maps produced with this model can be used for landscape level analysis of fire effects and to explore the relationship between fallen trees and forest structure, soil type, fire intensity or topography.
Fire Extinguisher Designated Worker and Fire Watch: Self-Study Course 15672
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, Jimmy D.
At Los Alamos National Laboratory (LANL), all workers must be aware of LANL fire protection policies and be trained on what to do in the event of a fire. This course, Fire Extinguisher Training for Fire Watch and Designated Workers (#9893), provides awareness-level and hands-on training for fire watch personnel and designated workers. Fire watch personnel and designated workers are appointed by line management and must receive both awareness-level training and hands-on training in the use of portable fire extinguishers to extinguish an incipient-stage fire. This training meets the requirements of the Occupational Safety and Health Administration (OSHA) Code ofmore » Federal Regulations (CFR) 29 CFR 1910.157, Portable Fire Extinguishers, and Procedure (P) 101-26, Welding, Cutting, and Other Spark-/Flame-Producing Operations.« less
[Forest lighting fire forecasting for Daxing'anling Mountains based on MAXENT model].
Sun, Yu; Shi, Ming-Chang; Peng, Huan; Zhu, Pei-Lin; Liu, Si-Lin; Wu, Shi-Lei; He, Cheng; Chen, Feng
2014-04-01
Daxing'anling Mountains is one of the areas with the highest occurrence of forest lighting fire in Heilongjiang Province, and developing a lightning fire forecast model to accurately predict the forest fires in this area is of importance. Based on the data of forest lightning fires and environment variables, the MAXENT model was used to predict the lightning fire in Daxing' anling region. Firstly, we studied the collinear diagnostic of each environment variable, evaluated the importance of the environmental variables using training gain and the Jackknife method, and then evaluated the prediction accuracy of the MAXENT model using the max Kappa value and the AUC value. The results showed that the variance inflation factor (VIF) values of lightning energy and neutralized charge were 5.012 and 6.230, respectively. They were collinear with the other variables, so the model could not be used for training. Daily rainfall, the number of cloud-to-ground lightning, and current intensity of cloud-to-ground lightning were the three most important factors affecting the lightning fires in the forest, while the daily average wind speed and the slope was of less importance. With the increase of the proportion of test data, the max Kappa and AUC values were increased. The max Kappa values were above 0.75 and the average value was 0.772, while all of the AUC values were above 0.5 and the average value was 0. 859. With a moderate level of prediction accuracy being achieved, the MAXENT model could be used to predict forest lightning fire in Daxing'anling Mountains.
Landscape characteristics of disturbed shrubsteppe habitats in southwestern Idaho (USA)
Knick, Steven T.; Rotenberry, J.T.
1997-01-01
We compared 5 zones in shrubsteppe habitats of southwestern Idaho to determine the effect of differing disturbance combinations on landscapes that once shared historically similar disturbance regimes. The primary consequence of agriculture, wildfires, and extensive fires ignited by the military during training activities was loss of native shrubs from the landscape. Agriculture created large square blocks on the landscape, and the landscape contained fewer small patches and more large shrub patches than non-agricultural areas. In contrast, fires left a more fragmented landscape. Repeated fires did not change the distribution of patch sizes, but decreased the total area of remaining shrublands and increased the distance between remaining shrub patches that provide seed sources. Military training with tracked vehicles was associated with a landscape characterized by small, closely spaced, shrub patches. Our results support the general model hypothesized for conversion of shrublands to annual grasslands by disturbance. Larger shrub patches in our region, historically resistant to fire spread and large-scale fires because of a perennial bunchgrass understory, were more fragmented than small patches. Presence of cheatgrass (Bromus tectorum), an exotic annual, was positively related to landscape patchiness and negatively related to number of shrub cells. Thus, cheatgrass dominance can contribute to further fragmentation and loss of the shrub patch by facilitating spread of subsequent fires, carried by continuous fuels, through the patch. The synergistic processes of fragmentation of shrub patches by disturbance, invasion and subsequent dominance by exotic annuals, and fire are converting shrubsteppe in southwestern Idaho to a new state dominated by exotic annual grasslands and high fire frequencies.
STS-48 crew participates in JSC fire fighting and fire training exercises
NASA Technical Reports Server (NTRS)
1991-01-01
STS-48 Mission Specialist (MS) Charles D. Gemar opens water hose nozzle as he approaches a fire blazing in JSC's Fire Training Pit during fire fighting and fire training exercises. Pilot Kenneth S. Reightler, Jr steadies the hose behind Gemar. At Gemars right is an unidentified fire department Official, MS Mark N. Brown, and Commander John O. Creighton. Brown and Crieghton are obscured by the water spray. The Fire Training Pit is located across from the Gilruth Center Bldg 207.
2016-11-01
Engagement Simulation Training, and a day of dry -fire. The comparison was conducted during training with iron sights. On the two criterion measures, the...other five days of training consisted of two days of Engagement Skills Trainer (EST) 2000 training, one day of dry -fire, and two days of live-fire...0 / RM1 Preliminary Marksmanship Training Same as Baseline 1 / RM2 EST 2000 (grouping/zeroing) Test-D Drills 2 / RM3 Dry -Fire Training 25m Live-Fire
29 CFR Appendix A to Subpart L of... - Fire Protection
Code of Federal Regulations, 2010 CFR
2010-07-01
... the International Fire Service Training Association, the National Fire Protection Association (NFPA-1041), the International Society of Fire Service Instructors and other fire training sources be... planning, and safety practices. It is again suggested that fire service training sources be consulted for...
30 CFR 75.1504 - Mine emergency evacuation training and drills.
Code of Federal Regulations, 2013 CFR
2013-07-01
... of travel to the surface, abandoned areas, and refuge alternatives. (5) Operation of the fire... communicate, until the miner reaches fresh air; and (iii) Proper use of the SCSR by controlling breathing and...) Breathing through a realistic SCSR training unit that provides the sensation of SCSR airflow resistance and...
30 CFR 75.1504 - Mine emergency evacuation training and drills.
Code of Federal Regulations, 2014 CFR
2014-07-01
... of travel to the surface, abandoned areas, and refuge alternatives. (5) Operation of the fire... communicate, until the miner reaches fresh air; and (iii) Proper use of the SCSR by controlling breathing and...) Breathing through a realistic SCSR training unit that provides the sensation of SCSR airflow resistance and...
30 CFR 75.1504 - Mine emergency evacuation training and drills.
Code of Federal Regulations, 2012 CFR
2012-07-01
... of travel to the surface, abandoned areas, and refuge alternatives. (5) Operation of the fire... communicate, until the miner reaches fresh air; and (iii) Proper use of the SCSR by controlling breathing and...) Breathing through a realistic SCSR training unit that provides the sensation of SCSR airflow resistance and...
30 CFR 75.1504 - Mine emergency evacuation training and drills.
Code of Federal Regulations, 2010 CFR
2010-07-01
... of travel to the surface, abandoned areas, and refuge alternatives. (5) Operation of the fire... communicate, until the miner reaches fresh air; and (iii) Proper use of the SCSR by controlling breathing and...) Breathing through a realistic SCSR training unit that provides the sensation of SCSR airflow resistance and...
30 CFR 75.1504 - Mine emergency evacuation training and drills.
Code of Federal Regulations, 2011 CFR
2011-07-01
... of travel to the surface, abandoned areas, and refuge alternatives. (5) Operation of the fire... communicate, until the miner reaches fresh air; and (iii) Proper use of the SCSR by controlling breathing and...) Breathing through a realistic SCSR training unit that provides the sensation of SCSR airflow resistance and...
STS-30 crewmembers participate in fire fighting training at JSC
NASA Technical Reports Server (NTRS)
1989-01-01
STS-30 Atlantis, Orbiter Vehicle (OV) 104, crewmembers participate in fire fighting training at JSC's fire training pit across from the Gilruth Center Bldg 207. Commander David M. Walker and Pilot Ronald J. Grabe use fire extinguishers to control blaze. Fire / security staff member Robert Fife coaches the two crewmembers during the training exercise.
Fire Problems in High-Rise Buildings. California Fire Service Training Program.
ERIC Educational Resources Information Center
California State Dept. of Education, Sacramento. Bureau of Industrial Education.
Resulting from a conference concerned with high-rise fire problems, this manual has been prepared as a fire department training manual and as a reference for students enrolled in fire service training courses. Information is provided for topics dealing with: (1) Typical Fire Problems in High-Rise Buildings, (2) Heat, (3) Smoke and Fire Gases, (4)…
Accidental fires in clinical laboratories.
Hoeltge, G A; Miller, A; Klein, B R; Hamlin, W B
1993-12-01
The National Fire Protection Association, Quincy, Mass, estimates that 169 fires have occurred annually in health care, medical, and chemical laboratories. On the average, there are 13 civilian injuries and $1.5 million per year in direct property damage. Most fires in which the cause or ignition source can be identified originate in malfunctioning electrical equipment (41.6%) or in the facility's electrical distribution system (14.7%). The prevalence of fire safety deficiencies was measured in the College of American Pathologists Laboratory Accreditation Program. Of the 1732 inspected laboratories, 5.5% lacked records of electrical receptacle polarity and ground checks in the preceding year. Of these inspected laboratories, 4.7% had no or incomplete documentation of electrical safety checks on laboratory instruments. There was no evidence of quarterly fire exit drills in 9% of the laboratories. Deficiencies were also found in precautionary labeling (6.8%), in periodic review of safe work practices (4.2%), in the use of safety cans (3.7%), and in venting of flammable liquid storage areas (2.8%). Fire preparedness would be improved if all clinical laboratories had smoke detectors and automatic fire-extinguishing systems. In-service training courses in fire safety should be targeted to the needs of specific service areas.
77 FR 35308 - Proposed Amendment of Restricted Area R-6601; Fort A.P. Hill, VA
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-13
...-0561; Airspace Docket No. 12-AEA-7] Proposed Amendment of Restricted Area R-6601; Fort A.P. Hill, VA...: This action proposes to expand the vertical limits and time of designation of restricted area R-6601... ceiling of restricted area R-6601. Currently, this training is conducted in a controlled firing area (CFA...
1992-03-29
Moreover, nuclear and coal-fired power plants could be built further away from high population areas. Magnetically levitated ( maglev ) trains may be the...Japanese bullet trains, going 120 miles/hour, must have their tracks realigned each night. The maglev trains would make this realignment unnecessary
ERIC Educational Resources Information Center
Cordell, Curtis C.; And Others
A training effectiveness evaluation of the Navy Advanced Fire Fighting Training System was conducted. This system incorporates simulated fires as well as curriculum materials and instruction. The fires are non-pollutant, computer controlled, and installed in a simulated shipboard environment. Two teams of 15 to 16 persons, with varying amounts of…
Incipient I Fire Brigade Training & Certification.
ERIC Educational Resources Information Center
Anoka-Hennepin Technical Coll., Minneapolis, MN.
This document contains course materials for the minimum general and Koch-specific requirements for the fire suppression training and education portion of the integrated industrial emergency response team training program. The various levels of performance were developed with the National Fire standard 600, Private Fire Brigades. The training is…
"Taking Women One Step Further..." Women in Technology. End of Year Report, July '93-June '94.
ERIC Educational Resources Information Center
El Paso Community Coll., TX.
The primary purpose of El Paso Community College's (EPCC's) Women in Technology (WIT) Program is to recruit women into nontraditional occupations through technical/vocational education and training. Credit training areas include automotive technology, drafting, electronics, fire technology, heating/ventilation and air conditioning, and welding.…
STS-42 crewmembers participate in JSC fire fighting training exercises
NASA Technical Reports Server (NTRS)
1991-01-01
STS-42 Discovery, Orbiter Vehicle (OV) 103, Payload Specialist Ulf D. Merbold (far left), fire fighting trainer (center), Payload Specialist Roberta L. Bondar (holding hose nozzle), and backup Payload Specialist Roger K. Crouch position water hoses in the direction of a blazing fire in JSC's Fire Training Pit. The crewmembers and backup are learning fire extinguishing techniques during fire fighting and fire training exercises held at JSC's Fire Training Pit located across from the Gilruth Center Bldg 207. Merbold is representing the European Space Agency (ESA) and Bondar is representing Canada during the International Microgravity Laboratory 1 (IML-1) mission aboard OV-103.
1984-04-01
firing ranges, and training areas--four conventional methods have been used to treat human wastes: trenching and cat holing, pit latrines, vault toilets...stations, and training and recrea- tional areas. The Army now uses four conventional methods to treat human wastes at such sites: trenching and cat ...holing, pit latrines, vault toilets, and chemical toilets ("port-a-pots"). Trenching and cat holing are used when troops are on bivouac; waste is
Fire Service Training. Rescue Practices. (Revised).
ERIC Educational Resources Information Center
North Carolina State Dept. of Community Colleges, Raleigh.
One of a set of fourteen instructional outlines for use in a course to train novice firemen, this guide covers the topic of rescue operations. Two types of rescue functions are recognized: the primary one consists of locating and saving trapped victims, and the secondary one of recovering bodies and making the area safe for other workers and…
STS-48 crew participates in JSC fire fighting and fire training exercises
NASA Technical Reports Server (NTRS)
1991-01-01
In this overall view, STS-48 crewmembers approach a firey blaze armed with water hoses. Left to right are Mission Specialist (MS) Charles D. Gemar, Pilot Kenneth S. Reightler, Jr, an unidentified fire department Official, MS Mark N. Brown, and Commander John O. Creighton. These fire fighting and fire training exercises were conducted at JSC's Fire Training Pit located across from the Gilruth Center Bldg 207.
OR fire virtual training simulator: design and face validity.
Dorozhkin, Denis; Olasky, Jaisa; Jones, Daniel B; Schwaitzberg, Steven D; Jones, Stephanie B; Cao, Caroline G L; Molina, Marcos; Henriques, Steven; Wang, Jinling; Flinn, Jeff; De, Suvranu
2017-09-01
The Virtual Electrosurgical Skill Trainer is a tool for training surgeons the safe operation of electrosurgery tools in both open and minimally invasive surgery. This training includes a dedicated team-training module that focuses on operating room (OR) fire prevention and response. The module was developed to allow trainees, practicing surgeons, anesthesiologist, and nurses to interact with a virtual OR environment, which includes anesthesia apparatus, electrosurgical equipment, a virtual patient, and a fire extinguisher. Wearing a head-mounted display, participants must correctly identify the "fire triangle" elements and then successfully contain an OR fire. Within these virtual reality scenarios, trainees learn to react appropriately to the simulated emergency. A study targeted at establishing the face validity of the virtual OR fire simulator was undertaken at the 2015 Society of American Gastrointestinal and Endoscopic Surgeons conference. Forty-nine subjects with varying experience participated in this Institutional Review Board-approved study. The subjects were asked to complete the OR fire training/prevention sequence in the VEST simulator. Subjects were then asked to answer a subjective preference questionnaire consisting of sixteen questions, focused on the usefulness and fidelity of the simulator. On a 5-point scale, 12 of 13 questions were rated at a mean of 3 or greater (92%). Five questions were rated above 4 (38%), particularly those focusing on the simulator effectiveness and its usefulness in OR fire safety training. A total of 33 of the 49 participants (67%) chose the virtual OR fire trainer over the traditional training methods such as a textbook or an animal model. Training for OR fire emergencies in fully immersive VR environments, such as the VEST trainer, may be the ideal training modality. The face validity of the OR fire training module of the VEST simulator was successfully established on many aspects of the simulation.
Barbaro, Jeffrey R.; Neupane, Pradumna P.
2002-01-01
Ground-water and surface-water sampling was conducted in the natural attenuation study area in the East Management Unit of Dover Air Force Base, Delaware to determine the distributions of volatile organic compounds in the vicinity of four sites?Fire Training Area Three, the Rubble Area Landfill, the Receiver Station Landfill, and the Liquid Waste Disposal Landfill. This work was done by the U.S. Geological Survey, in cooperation with the U.S. Air Force, as part of an ongoing assessment of the effectiveness of natural attenuation at these sites. The specific objectives of the study were to (1) determine the areal and vertical extent of the contaminant plumes and source areas, (2) measure volatile organic compound concentrations in ground-water discharge areas and in surface water under base-flow conditions, (3) evaluate the potential for off-site migration of the mapped plumes, and (4) estimate the amount of mass loss downgradient of the Liquid Waste Disposal and Receiver Station Landfills. A direct-push drill rig and previously installed multi-level piezometers were used to determine the three-dimensional distributions of volatile organic compounds in the 30?60-foot-thick surficial aquifer underlying the natural attenuation study area. A hand -driven mini-piezometer was used to collect ground-water samples in ground-water discharge areas. A total of 319 ground-water and 4 surface-water samples were collected from November 2000 to February 2001 and analyzed for chlorinated solvents and fuel hydrocarbons. The contaminant plumes migrating from Fire Training Area Three and the Rubble Area Landfill are approximately 500 feet and 800 feet, respectively, in length. These plumes consist predominantly of cis-1,2-dichloroethene, a daughter product, indicating that extensive dechlorination of tetrachloroethene and trichloroethene has occurred at these sites. With an approximate length of 2,200 feet, the plume migrating from the Receiver Station and Liquid Waste Disposal Landfills is the largest of the three plumes in the East Management Unit. In this plume, the parent compounds, tetrachloroethene and trichloroethene, as well as cis-1,2-dichloroethene, are present downgradient of the source. Vinyl chloride was not detected in the natural attenuation study area. Vertical water-quality profiles indicate that volatile organic compounds are present mainly in the upper part of the surficial aquifer. Plumes of fuel hydrocarbon constituents were not detected in the natural attenuation study area. Volatile organic compounds were present at concentrations above detection limits in 6 of 14 samples collected from the aquifer underlying the bed of Pipe Elm Branch and the drainage ditch adjacent to Fire Training Area Three, indicating that the plumes migrating from Fire Training Area Three and the Receiver Station and Liquid Waste Disposal Landfills are reaching these ground-water discharge areas. In contrast, sampling results indicated that the plume from the Rubble Area Landfill does not reach these ground-water discharge areas. Trichloroethene was present above detection limits in one of four surface-water samples collected from Pipe Elm Branch and the drainage ditch adjacent to Fire Training Area Three. The trichloroethene concentration is below applicable Delaware Department of Natural Resources and Environmental Control surface-water-quality standards for human health. An assessment of chlorinated-solvent mass loss in the plume migrating from the Receiver Station and Liquid Waste Disposal Landfills indicates that tetrachloroethene and trichloroethene mass loss downgradient of the source is negligible. Cis-1,2-dichloroethene, however, appears to biodegrade by an unidentified reaction in the plume. Plan-view maps of the plume migrating from the Receiver Station and Liquid Waste Disposal Landfills indicate that tetrachloroethene, trichloroethene, and cis-1,2-dichloroethene may migrate off Dover Air Force Base property approximately 1,500 f
Fire training in a virtual-reality environment
NASA Astrophysics Data System (ADS)
Freund, Eckhard; Rossmann, Jurgen; Bucken, Arno
2005-03-01
Although fire is very common in our daily environment - as a source of energy at home or as a tool in industry - most people cannot estimate the danger of a conflagration. Therefore it is important to train people in combating fire. Beneath training with propane simulators or real fires and real extinguishers, fire training can be performed in virtual reality, which means a pollution-free and fast way of training. In this paper we describe how to enhance a virtual-reality environment with a real-time fire simulation and visualisation in order to establish a realistic emergency-training system. The presented approach supports extinguishing of the virtual fire including recordable performance data as needed in teletraining environments. We will show how to get realistic impressions of fire using advanced particle-simulation and how to use the advantages of particles to trigger states in a modified cellular automata used for the simulation of fire-behaviour. Using particle systems that interact with cellular automata it is possible to simulate a developing, spreading fire and its reaction on different extinguishing agents like water, CO2 or oxygen. The methods proposed in this paper have been implemented and successfully tested on Cosimir, a commercial robot-and VR-simulation-system.
STS-42 crewmembers participate in JSC fire fighting training exercises
NASA Technical Reports Server (NTRS)
1991-01-01
STS-42 Discovery, Orbiter Vehicle (OV) 103, Mission Specialist (MS) Norman E. Thagard, holding hose nozzle, is followed by Payload Specialist Ulf D. Merbold and backup Payload Specialist Kenneth Money as the team positions the water hose in the direction of a blazing fire at JSC's Fire Training Pit. A second team of crewmembers, manning another hose, forms a line parallel to the first. The crewmembers and backups are learning fire extinguishing techniques during fire fighting and fire training exercises held at JSC's Fire Training Pit located across from the Gilruth Center Bldg 207. Merbold is representing the European Space Agency (ESA) during the International Microgravity Laboratory 1 (IML-1) mission aboard OV-103.
Engagement Skills Trainer: The Commander’s Perspective
2017-06-09
recommends using EST as a record of fire for a sustainment training event . This record of fire event can only occur once per year and after a live fire...mandatory part of marksmanship training. The author also recommends using EST as a record of fire for a sustainment training event . This record of fire... event can only occur once per year and after a live fire qualification. v ACKNOWLEDGMENTS The author would like to thank the following persons
The Human and Physical Determinants of Wildfires and Burnt Areas in Israel
NASA Astrophysics Data System (ADS)
Levin, Noam; Tessler, Naama; Smith, Andrew; McAlpine, Clive
2016-09-01
Wildfires are expected to increase in Mediterranean landscapes as a result of climate change and changes in land-use practices. In order to advance our understanding of human and physical factors shaping spatial patterns of wildfires in the region, we compared two independently generated datasets of wildfires for Israel that cover approximately the same study period. We generated a site-based dataset containing the location of 10,879 wildfires (1991-2011), and compared it to a dataset of burnt areas derived from MODIS imagery (2000-2011). We hypothesized that the physical and human factors explaining the spatial distribution of burnt areas derived from remote sensing (mostly large fires, >100 ha) will differ from those explaining site-based wildfires recorded by national agencies (mostly small fires, <10 ha). Small wildfires recorded by forestry agencies were concentrated within planted forests and near built-up areas, whereas the largest wildfires were located in more remote regions, often associated with military training areas and herbaceous vegetation. We conclude that to better understand wildfire dynamics, consolidation of wildfire databases should be achieved, combining field reports and remote sensing. As nearly all wildfires in Mediterranean landscapes are caused by human activities, improving the management of forest areas and raising public awareness to fire risk are key considerations in reducing fire danger.
The Human and Physical Determinants of Wildfires and Burnt Areas in Israel.
Levin, Noam; Tessler, Naama; Smith, Andrew; McAlpine, Clive
2016-09-01
Wildfires are expected to increase in Mediterranean landscapes as a result of climate change and changes in land-use practices. In order to advance our understanding of human and physical factors shaping spatial patterns of wildfires in the region, we compared two independently generated datasets of wildfires for Israel that cover approximately the same study period. We generated a site-based dataset containing the location of 10,879 wildfires (1991-2011), and compared it to a dataset of burnt areas derived from MODIS imagery (2000-2011). We hypothesized that the physical and human factors explaining the spatial distribution of burnt areas derived from remote sensing (mostly large fires, >100 ha) will differ from those explaining site-based wildfires recorded by national agencies (mostly small fires, <10 ha). Small wildfires recorded by forestry agencies were concentrated within planted forests and near built-up areas, whereas the largest wildfires were located in more remote regions, often associated with military training areas and herbaceous vegetation. We conclude that to better understand wildfire dynamics, consolidation of wildfire databases should be achieved, combining field reports and remote sensing. As nearly all wildfires in Mediterranean landscapes are caused by human activities, improving the management of forest areas and raising public awareness to fire risk are key considerations in reducing fire danger.
Fire/security staff member instructs STS-29 crew on fire extinguisher usage
NASA Technical Reports Server (NTRS)
1988-01-01
STS-29 Discovery, Orbiter Vehicle (OV) 103, crewmembers are trained in procedures to follow in the event of a fire. Here, the crew is briefed on the correct handling of the fire extinguisher by Robert Fife (far left) of NASA's fire / security staff. Pictured, left to right are Pilot John E. Blaha, Commander Michael L. Coats, Mission Specialist (MS) Robert C. Springer, MS James F. Buchli, and MS James P. Bagian. The in fire fighting training took place at JSC's fire training pit across from the Gilruth Center Bldg 207.
Zhuang, Chengxu; Wang, Yulong; Yamins, Daniel; Hu, Xiaolin
2017-01-01
Visual information in the visual cortex is processed in a hierarchical manner. Recent studies show that higher visual areas, such as V2, V3, and V4, respond more vigorously to images with naturalistic higher-order statistics than to images lacking them. This property is a functional signature of higher areas, as it is much weaker or even absent in the primary visual cortex (V1). However, the mechanism underlying this signature remains elusive. We studied this problem using computational models. In several typical hierarchical visual models including the AlexNet, VggNet, and SHMAX, this signature was found to be prominent in higher layers but much weaker in lower layers. By changing both the model structure and experimental settings, we found that the signature strongly correlated with sparse firing of units in higher layers but not with any other factors, including model structure, training algorithm (supervised or unsupervised), receptive field size, and property of training stimuli. The results suggest an important role of sparse neuronal activity underlying this special feature of higher visual areas.
Zhuang, Chengxu; Wang, Yulong; Yamins, Daniel; Hu, Xiaolin
2017-01-01
Visual information in the visual cortex is processed in a hierarchical manner. Recent studies show that higher visual areas, such as V2, V3, and V4, respond more vigorously to images with naturalistic higher-order statistics than to images lacking them. This property is a functional signature of higher areas, as it is much weaker or even absent in the primary visual cortex (V1). However, the mechanism underlying this signature remains elusive. We studied this problem using computational models. In several typical hierarchical visual models including the AlexNet, VggNet, and SHMAX, this signature was found to be prominent in higher layers but much weaker in lower layers. By changing both the model structure and experimental settings, we found that the signature strongly correlated with sparse firing of units in higher layers but not with any other factors, including model structure, training algorithm (supervised or unsupervised), receptive field size, and property of training stimuli. The results suggest an important role of sparse neuronal activity underlying this special feature of higher visual areas. PMID:29163117
Ultrafine and respirable particle exposure during vehicle fire suppression
Fent, Kenneth W.
2015-01-01
Vehicle fires are a common occurrence, yet few studies have reported exposures associated with burning vehicles. This article presents an assessment of firefighters’ potential for ultrafine and respirable particle exposure during vehicle fire suppression training. Fires were initiated within the engine compartment and passenger cabins of three salvaged vehicles, with subsequent water suppression by fire crews. Firefighter exposures were monitored with an array of direct reading particle and air quality instruments. A flexible metallic duct and blower drew contaminants to the instrument array, positioned at a safe distance from the burning vehicles, with the duct inlet positioned at the nozzle operator’s shoulder. The instruments measured the particle number, active surface area, respirable particle mass, photoelectric response, aerodynamic particle size distributions, and air quality parameters. Although vehicle fires were suppressed quickly (<10 minutes), firefighters may be exposed to short duration, high particle concentration episodes during fire suppression, which are orders of magnitude greater than the ambient background concentration. A maximum transient particle concentration of 1.21 × 107 particles per cm3, 170 mg m−3 respirable particle mass, 4700 μm2 cm−3 active surface area and 1400 (arbitrary units) in photoelectric response were attained throughout the series of six fires. Expressed as fifteen minute time-weighted averages, engine compartment fires averaged 5.4 × 104 particles per cm3, 0.36 mg m−3 respirable particle mass, 92 μm2 cm−3 active particle surface area and 29 (arbitrary units) in photoelectric response. Similarly, passenger cabin fires averaged 2.04 × 105 particles per cm3, 2.7 mg m−3 respirable particle mass, 320 μm2 cm−3 active particle surface area, and 34 (arbitrary units) in photoelectric response. Passenger cabin fires were a greater potential source of exposure than engine compartment fires. The wind direction and the relative position of the fire crew to the stationary burning vehicle played a primary role in fire crews’ potential for exposure. We recommend that firefighters wear self-contained breathing apparatus during all phases of the vehicle fire response to significantly reduce their potential for particulate, vapor, and gaseous exposures. PMID:26308547
Ultrafine and respirable particle exposure during vehicle fire suppression.
Evans, Douglas E; Fent, Kenneth W
2015-10-01
Vehicle fires are a common occurrence, yet few studies have reported exposures associated with burning vehicles. This article presents an assessment of firefighters' potential for ultrafine and respirable particle exposure during vehicle fire suppression training. Fires were initiated within the engine compartment and passenger cabins of three salvaged vehicles, with subsequent water suppression by fire crews. Firefighter exposures were monitored with an array of direct reading particle and air quality instruments. A flexible metallic duct and blower drew contaminants to the instrument array, positioned at a safe distance from the burning vehicles, with the duct inlet positioned at the nozzle operator's shoulder. The instruments measured the particle number, active surface area, respirable particle mass, photoelectric response, aerodynamic particle size distributions, and air quality parameters. Although vehicle fires were suppressed quickly (<10 minutes), firefighters may be exposed to short duration, high particle concentration episodes during fire suppression, which are orders of magnitude greater than the ambient background concentration. A maximum transient particle concentration of 1.21 × 10(7) particles per cm(3), 170 mg m(-3) respirable particle mass, 4700 μm(2) cm(-3) active surface area and 1400 (arbitrary units) in photoelectric response were attained throughout the series of six fires. Expressed as fifteen minute time-weighted averages, engine compartment fires averaged 5.4 × 10(4) particles per cm(3), 0.36 mg m(-3) respirable particle mass, 92 μm(2) cm(-3) active particle surface area and 29 (arbitrary units) in photoelectric response. Similarly, passenger cabin fires averaged 2.04 × 10(5) particles per cm(3), 2.7 mg m(-3) respirable particle mass, 320 μm(2) cm(-3) active particle surface area, and 34 (arbitrary units) in photoelectric response. Passenger cabin fires were a greater potential source of exposure than engine compartment fires. The wind direction and the relative position of the fire crew to the stationary burning vehicle played a primary role in fire crews' potential for exposure. We recommend that firefighters wear self-contained breathing apparatus during all phases of the vehicle fire response to significantly reduce their potential for particulate, vapor, and gaseous exposures.
46 CFR 185.524 - Fire fighting drills and training.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Fire fighting drills and training. 185.524 Section 185... 100 GROSS TONS) OPERATIONS Preparations for Emergencies § 185.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar...
46 CFR 185.524 - Fire fighting drills and training.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Fire fighting drills and training. 185.524 Section 185... 100 GROSS TONS) OPERATIONS Preparations for Emergencies § 185.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar...
46 CFR 185.524 - Fire fighting drills and training.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Fire fighting drills and training. 185.524 Section 185... 100 GROSS TONS) OPERATIONS Preparations for Emergencies § 185.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar...
46 CFR 185.524 - Fire fighting drills and training.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Fire fighting drills and training. 185.524 Section 185... 100 GROSS TONS) OPERATIONS Preparations for Emergencies § 185.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar...
46 CFR 185.524 - Fire fighting drills and training.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Fire fighting drills and training. 185.524 Section 185... 100 GROSS TONS) OPERATIONS Preparations for Emergencies § 185.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar...
STS-48 crew participates in JSC fire fighting and fire training exercises
NASA Technical Reports Server (NTRS)
1991-01-01
STS-48 Pilot Kenneth S. Reightler, Jr directs water hose nozzle as Mission Specialist (MS) Charles D. Gemar pulls the hose toward the blaze. In the background, an unidentified fire department Official instructs Commander John O. Creighton and MS Mark N. Brown (wearing cap), manning a second hose, on how to approach the blaze. These fire fighting and fire training exercises were conducted at JSC's Fire Training Pit located across from the Gilruth Center Bldg 207.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-23
... Equipment, Training and Drills Onboard Offshore Facilities and Mobile Offshore Drilling Units (MODUs... lifesaving and fire-fighting equipment, training and drills on board offshore facilities and MODUs operating... guidance concerning lifesaving and fire-fighting equipment, training, and drills onboard manned offshore...
2014-04-30
CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, a Fire Rescue vehicle stands by in a parking area near the Vehicle Assembly Building for training with pilots in NASA Aircraft Operations. The exercise is designed to develop procedures for using agency helicopters to transport injured patients to a local hospital. The activity taking place in Kennedy's Launch Complex 39 turn-basin parking lot was only one of several drills. It was part of a new training program that was developed by Kennedy's Fire Rescue department along with NASA Aircraft Operations to sharpen the skills needed to help rescue personnel learn how to collaborate with helicopter pilots in taking injured patients to hospitals as quickly as possible. Photo credit: NASA/Dan Casper
2014-04-29
CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, Fire Rescue vehicles line up in a parking area near the Vehicle Assembly Building for training with pilots in NASA Aircraft Operations. The exercise is designed to develop procedures for using agency helicopters to transport injured patients to a local hospital. The activity taking place in Kennedy's Launch Complex 39 turn-basin parking lot was only one of several drills. It was part of a new training program that was developed by Kennedy's Fire Rescue department along with NASA Aircraft Operations to sharpen the skills needed to help rescue personnel learn how to collaborate with helicopter pilots in taking injured patients to hospitals as quickly as possible. Photo credit: NASA/Dan Casper
Mapping Fire Severity Using Imaging Spectroscopy and Kernel Based Image Analysis
NASA Astrophysics Data System (ADS)
Prasad, S.; Cui, M.; Zhang, Y.; Veraverbeke, S.
2014-12-01
Improved spatial representation of within-burn heterogeneity after wildfires is paramount to effective land management decisions and more accurate fire emissions estimates. In this work, we demonstrate feasibility and efficacy of airborne imaging spectroscopy (hyperspectral imagery) for quantifying wildfire burn severity, using kernel based image analysis techniques. Two different airborne hyperspectral datasets, acquired over the 2011 Canyon and 2013 Rim fire in California using the Airborne Visible InfraRed Imaging Spectrometer (AVIRIS) sensor, were used in this study. The Rim Fire, covering parts of the Yosemite National Park started on August 17, 2013, and was the third largest fire in California's history. Canyon Fire occurred in the Tehachapi mountains, and started on September 4, 2011. In addition to post-fire data for both fires, half of the Rim fire was also covered with pre-fire images. Fire severity was measured in the field using Geo Composite Burn Index (GeoCBI). The field data was utilized to train and validate our models, wherein the trained models, in conjunction with imaging spectroscopy data were used for GeoCBI estimation wide geographical regions. This work presents an approach for using remotely sensed imagery combined with GeoCBI field data to map fire scars based on a non-linear (kernel based) epsilon-Support Vector Regression (e-SVR), which was used to learn the relationship between spectra and GeoCBI in a kernel-induced feature space. Classification of healthy vegetation versus fire-affected areas based on morphological multi-attribute profiles was also studied. The availability of pre- and post-fire imaging spectroscopy data over the Rim Fire provided a unique opportunity to evaluate the performance of bi-temporal imaging spectroscopy for assessing post-fire effects. This type of data is currently constrained because of limited airborne acquisitions before a fire, but will become widespread with future spaceborne sensors such as those on the planned NASA HyspIRI mission.
Design and Realization of Ship Fire Simulation Training System Based on Unity3D
NASA Astrophysics Data System (ADS)
Ting, Ye; Feng, Chen; Wenqiang, Wang; Kai, Yang
2018-01-01
Ship fire training is a very important training to ensure the safety of the ship, but limited by the characteristics of the ship itself, it is difficult to carry out fire training on the ship. This paper proposes to introduce a virtual reality technology to build a set of ship fire simulation training system, used to improve the quality of training, reduce training costs. First, the system design ideas are elaborated, and the system architecture diagram is given. Then, the key technologies in the process of system implementation are analyzed. Finally, the system examples are built and tested.
Satellite-based products for forest fire prevention and recovery: the PREFER experience
NASA Astrophysics Data System (ADS)
Laneve, Giovanni; Bernini, Guido; Fusilli, Lorenzo; Marzialetti, Pablo
2016-08-01
PREFER is a three years projects funded in 2012 in the framework of the FP7 Emergency call. The project objective was to set up a space-based service infrastructure and up-to-date cartographic products, based on remote sensing data, to support the preparedness, prevention, recovery and reconstruction phases of the Forest Fires emergency cycle in the European Mediterranean Region. The products of PREFER were tested and evaluated during the training and the demonstration period of the project, which coincided with the forest fire season of 2015. The products were tested using the online PREFER service and the tests were linked to the pilot areas of the project which are Minho (Portugal), Messenia (Greece), Andalucía (Spain), Sardinia (Italy) and Corse (France). Testing was performed by members of the User Advisory Board (UAB) starting from the training event organized in Coimbra, Portugal in June 2015. The tests continued till the end of the fire season (October 2015) and the end users were provided with updated information for the areas of interest during the entire demonstration period. Due to data availability restrictions (in particular to ancillary required data) not all products were available for testing in all the test areas. However all the PREFER products were tested at least in one pilot area and in cooperation with at least one end user organization. It has to be mentioned that beyond the product suitability and usefulness to the end users the tests included evaluation of the usability of the web-based service of PREFER and the respective quality of service provided. This paper aims at presenting the results of the demonstration activity, the lessons learned and ideas for further enhancement of the developed products devoted to support prevention and recovery phases of the wildfire cycle.
STS-32 crewmembers use water hose during exercises at JSC fire training pit
NASA Technical Reports Server (NTRS)
1989-01-01
STS-32 Commander Daniel C. Brandenstein (left) and Pilot James D. Wetherbee handle water hose during fire training exercises conducted at JSC Fire Training Pit across from the Gilruth Center Bldg 207.
Lanza, Heather A; Cochran, Rebecca S; Mudge, Joseph F; Olson, Adric D; Blackwell, Brett R; Maul, Jonathan D; Salice, Christopher J; Anderson, Todd A
2017-08-01
Perfluoroalkyl substances (PFAS) have recently received increased research attention, particularly concerning aquatic organisms and in regions of exposure to aqueous film forming foams (AFFFs). Air Force bases historically applied AFFFs in the interest of fire training exercises and have since expressed concern for PFAS contamination in biota from water bodies surrounding former fire training areas. Six PFAS were monitored, including perfluorooctane sulfonate (PFOS), in aquatic species from 8 bayou locations at Barksdale Air Force Base in Bossier City, Louisiana (USA) over the course of 1 yr. The focus was to evaluate temporal and spatial variability in PFAS concentrations from historic use of AFFF. The PFOS concentrations in fish peaked in early summer, and also increased significantly downstream of former fire training areas. Benthic organisms had lower PFOS concentrations than pelagic species, contrary to previous literature observations. Bioconcentration factors varied with time but were reduced compared with previously reported literature values. The highest concentration of PFOS in whole fish was 9349 ng/g dry weight, with 15% of samples exceeding what is believed to be the maximum whole fish concentration reported to date of 1500 ng/g wet weight. Further studies are ongoing, to measure PFAS in larger fish and tissue-specific partitioning data to compare with the current whole fish values. The high concentrations presently observed could have effects on higher trophic level organisms in this system or pose a potential risk to humans consuming contaminated fish. Environ Toxicol Chem 2017;36:2022-2029. © 2016 SETAC. © 2016 SETAC.
46 CFR 122.524 - Fire fighting drills and training.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Fire fighting drills and training. 122.524 Section 122... Preparations for Emergencies § 122.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a...
46 CFR 122.524 - Fire fighting drills and training.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Fire fighting drills and training. 122.524 Section 122... Preparations for Emergencies § 122.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a...
46 CFR 122.524 - Fire fighting drills and training.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Fire fighting drills and training. 122.524 Section 122... Preparations for Emergencies § 122.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a...
46 CFR 122.524 - Fire fighting drills and training.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Fire fighting drills and training. 122.524 Section 122... Preparations for Emergencies § 122.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a...
46 CFR 122.524 - Fire fighting drills and training.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Fire fighting drills and training. 122.524 Section 122... Preparations for Emergencies § 122.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a...
Maryland Fire-Rescue Education and Training System. Organizational Design.
ERIC Educational Resources Information Center
Maryland Fire-Rescue Education and Training Commission.
This is a description of the Maryland system which was created to evaluate local fire-rescue education and training needs and capabilities and to assist local authorities with fire-rescue education and training. In the first of four parts, an historical presentation is used to identify and describe in general terms the state fire, rescue, and…
Training and Education in the Fire Services (Proceedings of a Symposium, April 8-9 1970).
ERIC Educational Resources Information Center
National Academy of Sciences-National Research Council, Washington, DC. Div. of Engineering.
Issues in the improvement of training for fire fighters and officer personnel were taken up in ten symposium papers. Session I covered legal and other constraints that affect what a fire fighter should know; and current practices in volunteer, rural, and municipal fire fighter training in the United States. Papers from the other sessions dealt…
Water in Fire Control--Basic Training Course.
ERIC Educational Resources Information Center
Forest Service (USDA), Washington, DC.
Prepared by a team of fire control officers, the training guide is designed to help fire crewmen learn the fundamentals of water use. The entire package can be used for a complete course or individual lessons and can be adapted to specific training needs. Throughout the guide, emphasis is placed on one primary training objective, performance in…
Training Fires on Indian Reservations in Idaho, Oregon, and Washington
The Federal Air Rules for Reservations (FARR) Open Burning Rule allows Fire Protection Services to request permission from EPA to conduct an outdoor burn by qualified personnel to train firefighters on fire suppression and fire fighting techniques.
FIRE SERVICE TRAINING, INSTRUCTOR'S MANUAL, BASIC COURSE.
ERIC Educational Resources Information Center
BERNDT, WILLIAM M.; AND OTHERS
INSTRUCTORS CAN USE THIS MANUAL IN CONDUCTING A 34-HOUR FIRE STATION OR TRAINING CENTER EXTENSION PROGRAM TO IMPROVE THE COMPETENCIES AND SKILLS OF LOCAL FIRE PERSONNEL IN THE SPECIALIZED FIELD OF FIRE SERVICE. IT WAS DEVELOPED BY A STATEWIDE COMMITTEE OF FIRE FIGHTING CONSULTANTS AND ADVISORY GROUPS. THE 26 TEACHING GUIDES PROVIDE INSTRUCTIONAL…
2010-04-12
truancy, exploding crime rates, and waning family values that created a sense of desolation within the community.23 Drive-by shootings killed three...Fire Depart- ment. 51 Augmenting the response with National Guard forces also helped stop the increase in fires and crimes in the area.62 Just before... seditions and insurrections. While Federalist No. 29 recommended forming a highly trained militia to a:pply necessary force correctly.2 The Calling
STS-30 crewmembers participate in fire fighting training at JSC
NASA Technical Reports Server (NTRS)
1989-01-01
STS-30 Atlantis, Orbiter Vehicle (OV) 104, crewmembers participate in fire fighting training at JSC's fire training pit across from the Gilruth Center Bldg 207. Crewmembers listen to hose and nozzle instructions given by fire / security staff member Robert Fife. Left to right Commander David M. Walker (holding hose nozzle), Mission Specialist (MS) Mark C. Lee, MS Mary L. Cleave, Pilot Ronald J. Grabe, and MS Norman E. Thagard.
Fire detection from hyperspectral data using neural network approach
NASA Astrophysics Data System (ADS)
Piscini, Alessandro; Amici, Stefania
2015-10-01
This study describes an application of artificial neural networks for the recognition of flaming areas using hyper- spectral remote sensed data. Satellite remote sensing is considered an effective and safe way to monitor active fires for environmental and people safeguarding. Neural networks are an effective and consolidated technique for the classification of satellite images. Moreover, once well trained, they prove to be very fast in the application stage for a rapid response. At flaming temperature, thanks to its low excitation energy (about 4.34 eV), potassium (K) ionize with a unique doublet emission features. This emission features can be detected remotely providing a detection map of active fire which allows in principle to separate flaming from smouldering areas of vegetation even in presence of smoke. For this study a normalised Advanced K Band Difference (AKBD) has been applied to airborne hyper spectral sensor covering a range of 400-970 nm with resolution 2.9 nm. A back propagation neural network was used for the recognition of active fires affecting the hyperspectral image. The network was trained using all channels of sensor as inputs, and the corresponding AKBD indexes as target output. In order to evaluate its generalization capabilities, the neural network was validated on two independent data sets of hyperspectral images, not used during neural network training phase. The validation results for the independent data-sets had an overall accuracy round 100% for both image and a few commission errors (0.1%), therefore demonstrating the feasibility of estimating the presence of active fires using a neural network approach. Although the validation of the neural network classifier had a few commission errors, the producer accuracies were lower due to the presence of omission errors. Image analysis revealed that those false negatives lie in "smoky" portion fire fronts, and due to the low intensity of the signal. The proposed method can be considered effective both in terms of classification accuracy and generalization capability. In particular our approach proved to be robust in the rejection of false positives, often corresponding to noisy or smoke pixels, whose presence in hyperspectral images can often undermine the performance of traditional classification algorithms. In order to improve neural network performance, future activities will include also the exploiting of hyperspectral images in the shortwave infrared region of the electromagnetic spectrum, covering wavelengths from 1400 to 2500 nm, which include significant emitted radiance from fire.
Applying Open Source Game Engine for Building Visual Simulation Training System of Fire Fighting
NASA Astrophysics Data System (ADS)
Yuan, Diping; Jin, Xuesheng; Zhang, Jin; Han, Dong
There's a growing need for fire departments to adopt a safe and fair method of training to ensure that the firefighting commander is in a position to manage a fire incident. Visual simulation training systems, with their ability to replicate and interact with virtual fire scenarios through the use of computer graphics or VR, become an effective and efficient method for fire ground education. This paper describes the system architecture and functions of a visual simulated training system of fire fighting on oil storage, which adopting Delat3D, a open source game and simulation engine, to provide realistic 3D views. It presents that using open source technology provides not only the commercial-level 3D effects but also a great reduction of cost.
NASA Astrophysics Data System (ADS)
Tajedi, Noor Aqilah A.; Sukor, Nur Sabahiah A.; Ismail, Mohd Ashraf M.; Shamsudin, Shahrul A.
2017-10-01
The purpose of this paper is to compare the fire evacuation plan and preparation at the underground train stations in the different countries. The methodology for this study was using the extended questionnaire survey to investigate the Rapid Rail Sdn Bhd, Malaysia's fire safety plan and preparation at the underground train stations. There were four sections in the questionnaire which included (i) background of the respondents, (ii) the details on the train stations, safety instruction and fire evacuation exercises (iii) technical systems, installation and equipment at the underground stations and (iv) procedures and technical changes related to fire safety that had been applied by the operators. Previously, the respondents from the different train operator services in the developed countries had completed the questionnaires. This paper extends the response from the Rapid Rail Sdn Bhd to compare the emergency procedures and preparation for fire event with the developed countries. As a result, this study found that the equipment and facilities that provided at the underground train stations that operated by Rapid Rail are relevant for fire safety procedures and needs. The main advantage for Rapid Rail is the underground stations were designed with two or more entrances/exits that may perform better evacuation compare to one main entrance/exit train stations in the other developed countries.
Mapping burned areas using dense time-series of Landsat data
Hawbaker, Todd J.; Vanderhoof, Melanie; Beal, Yen-Ju G.; Takacs, Joshua; Schmidt, Gail L.; Falgout, Jeff T.; Williams, Brad; Brunner, Nicole M.; Caldwell, Megan K.; Picotte, Joshua J.; Howard, Stephen M.; Stitt, Susan; Dwyer, John L.
2017-01-01
Complete and accurate burned area data are needed to document patterns of fires, to quantify relationships between the patterns and drivers of fire occurrence, and to assess the impacts of fires on human and natural systems. Unfortunately, in many areas existing fire occurrence datasets are known to be incomplete. Consequently, the need to systematically collect burned area information has been recognized by the United Nations Framework Convention on Climate Change and the Intergovernmental Panel on Climate Change, which have both called for the production of essential climate variables (ECVs), including information about burned area. In this paper, we present an algorithm that identifies burned areas in dense time-series of Landsat data to produce the Landsat Burned Area Essential Climate Variable (BAECV) products. The algorithm uses gradient boosted regression models to generate burn probability surfaces using band values and spectral indices from individual Landsat scenes, lagged reference conditions, and change metrics between the scene and reference predictors. Burn classifications are generated from the burn probability surfaces using pixel-level thresholding in combination with a region growing process. The algorithm can be applied anywhere Landsat and training data are available. For this study, BAECV products were generated for the conterminous United States from 1984 through 2015. These products consist of pixel-level burn probabilities for each Landsat scene, in addition to, annual composites including: the maximum burn probability and a burn classification. We compared the BAECV burn classification products to the existing Global Fire Emissions Database (GFED; 1997–2015) and Monitoring Trends in Burn Severity (MTBS; 1984–2013) data. We found that the BAECV products mapped 36% more burned area than the GFED and 116% more burned area than MTBS. Differences between the BAECV products and the GFED were especially high in the West and East where the BAECV products mapped 32% and 88% more burned area, respectively. However, the BAECV products found less burned area than the GFED in regions with frequent agricultural fires. Compared to the MTBS data, the BAECV products identified 31% more burned area in the West, 312% more in the Great Plains, and 233% more in the East. Most pixels in the MTBS data were detected by the BAECV, regardless of burn severity. The BAECV products document patterns of fire similar to those in the GFED but also showed patterns of fire that are not well characterized by the existing MTBS data. We anticipate the BAECV products will be useful to studies that seek to understand past patterns of fire occurrence, the drivers that created them, and the impacts fires have on natural and human systems.
Weiss, Odulf; Wiesmüller, Gerhard A; Bunte, Anne; Göen, Thomas; Schmidt, Carsten K; Wilhelm, Michael; Hölzer, Jürgen
2012-02-01
In Cologne, Germany, increased concentrations of perfluorinated compounds (PFC) have been observed in two private wells used for drinking water purposes. Both wells are located in the vicinity of a fire training area. Use of well water as a source of drinking water was prohibited by the Public Health Department of the City of Cologne. A human biomonitoring (HBM) survey was performed among all persons, who consumed water from these private wells (N=10). PFC concentrations in water of the private wells and in blood samples were analysed by tandem mass spectrometry with electrospray ionization (LC-ESI-MS/MS). Repeated water analyses (seven measurements between December 2009 and November 2010) indicated a decrease of PFOS from 8.35 to 1.60 μg/l, (PFHxS: 2.36-0.15 μg/l; PFOA: 0.16-0.03 μg/l) in one private well. Although situated close together, PFC-concentrations in the other private well were significantly lower. PFOS-concentrations in blood samples of private well water consumers ranged from 4.8 to 295 μg/l (PFHxS: 12.1-205 μg/l; PFOA: 4.0-18 μg/l). Although no data on the formulation of the firefighting foams applied on the fire training area is available, firefighting foams are supposed to be the most likely source of contamination. These findings give reason to track systematically the application of PFC-containing firefighting foams in order to identify contaminations of surface, ground and drinking waters. Copyright © 2011 Elsevier GmbH. All rights reserved.
The Effect of Computer-Based Simulation Training on Fire Ground Incident Commander Decision Making
ERIC Educational Resources Information Center
Hall, Kurt A.
2010-01-01
Since the establishment of the first volunteer fire brigades in the United States, firefighters have lost their lives in fire fighting operations at emergency incidents and live-fire training activities. While there are various reasons for these firefighter deaths and injuries, the United States Fire Administration (2002) reported that many of…
2014-11-01
SV © Her Majesty the Queen in Right of Canada, as represented by the Minister of National Defence, 2014 © Sa Majesté la Reine (en droit du Canada... dragged over to fire hydrants to be attached to the steamer caps. Bolt cutters can be used to cut holes in fences allowing better access to the train...derailment fire. Ground monitors (for blitz fire) can be positioned for fire attack. 65mm attack lines can be dragged from fire engines and
STS-29 crewmembers participate in fire fighting training at JSC
NASA Technical Reports Server (NTRS)
1988-01-01
STS-29 Discovery, Orbiter Vehicle (OV) 103, crewmembers participate in fire fighting training at JSC's fire training pit across from the Gilruth Center Bldg 207. Mission Specialist (MS) Robert C. Springer (left) and Pilot John E. Blaha, controlling water hose nozzles, approach the blaze and attempt to extinguish it. They are followed by fire / security staff member Robert Fife (between hoses), Commander Michael L. Coats (left), and MS James P. Bagian.
ENHANCED REMEDIATION DEMONSTRATIONS AT HILL AFB: INTRODUCTION
Nine enhanced aquifer remediation technologies were demonstrated side-by-side at a Hill Air Force Base Chemical Disposal Pit/Fire Training Area site. The demonstrations were performed inside 3 x 5 m cells isolated from the surrounding shallow aquifer by steel piling. The site w...
Orbiter fire rescue and crew escape training for EVA crew systems support
1993-01-28
Photos of orbiter fire rescue and crew escape training for extravehicular activity (EVA) crew systems support conducted in Bldg 9A Crew Compartment Trainer (CCT) and Fuel Fuselage Trainer (FFT) include views of CCT interior of middeck starboard fuselage showing middeck forward (MF) locker and COAS assembly filter, artiflex film and camcorder bag (26834); launch/entry suit (LES) helmet assembly, neckring and helmet hold-down assembly (26835-26836); middeck aft (MA) lockers (26837); area of middeck airlock and crew escape pole (26838); connectors of crew escape pole in the middeck (268390); three test subjects in LES in the flight deck (26840); emergency side hatch slide before inflated stowage (26841); area of below adjacent to floor panel MD23R (26842); a test subject in LES in the flight deck (26843); control board and also showing sign of "orbital maneuvering system (OMS) secure and OMS TK" (26844); test subject in the flight deck also showing chart of "ascent/abort summary" (26845).
Anderson, R Hunter; Long, G Cornell; Porter, Ronald C; Anderson, Janet K
2016-05-01
The use of aqueous film-forming foam (AFFF) to extinguish hydrocarbon-based fires is recognized as a significant source of environmental poly- and perfluoroalkyl substances (PFASs). Although the occurrence of select PFASs in soil and groundwater at former fire-training areas (FTAs) at military installations operable since 1970 has been consistently confirmed, studies reporting the occurrence of PFASs at other AFFF-impacted sites (e.g. emergency response locations, AFFF lagoons, hangar-related AFFF storage tanks and pipelines, and fire station testing and maintenance areas) are largely missing from the literature. Further, studies have mostly focused on a single site (i.e., FTAs at military installations) and, thus, lack a comparison of sites with diverse AFFF release history. Therefore, the purpose of this investigation was to evaluate select PFAS occurrence at non-FTA sites on active U.S. Air Force installations with historic AFFF use of varying magnitude. Concentrations of fifteen perfluoroalkyl acids (PFAAs) and perfluorooctane sulfonamide (PFOSA), an important PFOS precursor, were measured from several hundred samples among multiple media (i.e., surface soil, subsurface soil, sediment, surface water, and groundwater) collected from forty AFFF-impacted sites across ten installations between March and September 2014, representing one of the most comprehensive datasets on environmental PFAS occurrence to date. Differences in detection frequencies and observed concentrations due to AFFF release volume are presented along with rigorous data analyses that quantitatively demonstrate phase-dependent (i.e., solid-phase vs aqueous-phase) differences in the chemical signature as a function of carbon chain-length and in situ PFOS (and to a slightly lesser extent PFHxS) formation, presumably due to precursor biotransformation. Published by Elsevier Ltd.
Lead Exposure in Military Outdoor Firing Ranges.
Greenberg, Nili; Frimer, Ron; Meyer, Robert; Derazne, Estella; Chodick, Gabrial
2016-09-01
Several studies have reported significant airborne lead exposures during training at indoor firing ranges. Scarce attention has been given to airborne lead exposures in outdoor shooting ranges with automatic weapons. To assess the prevalence and magnitude of airborne and blood lead levels (BLL) among firing instructors and shooters in military outdoor ranges. Exposure assessment, for both trainees and instructors, included airborne and BLL during basic and advanced training at outdoor firing ranges. Personal airborne samples were collected in both day and night shooting during both training periods. During basic training, there is 95% likelihood that up to 25% of instructors and 99% likelihood that up to 5% of trainees might be exposed above the action level (AL) (25 μg/m(3)). During advanced training, there is 90% likelihood that 10% of instructors and 99% likelihood that up to 10% of trainees might be exposed above the AL. Military personnel participating in automatic weapon marksmanship training can be exposed to considerable levels of airborne lead during outdoor firing range training. As a result, the Israel Defense Force Medical Corp has classified firing range instructors as workers that require periodic medical examinations. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.
Holmes, William R; Huwe, Janice A; Williams, Barbara; Rowe, Michael H; Peterson, Ellengene H
2017-05-01
Vestibular bouton afferent terminals in turtle utricle can be categorized into four types depending on their location and terminal arbor structure: lateral extrastriolar (LES), striolar, juxtastriolar, and medial extrastriolar (MES). The terminal arbors of these afferents differ in surface area, total length, collecting area, number of boutons, number of bouton contacts per hair cell, and axon diameter (Huwe JA, Logan CJ, Williams B, Rowe MH, Peterson EH. J Neurophysiol 113: 2420-2433, 2015). To understand how differences in terminal morphology and the resulting hair cell inputs might affect afferent response properties, we modeled representative afferents from each region, using reconstructed bouton afferents. Collecting area and hair cell density were used to estimate hair cell-to-afferent convergence. Nonmorphological features were held constant to isolate effects of afferent structure and connectivity. The models suggest that all four bouton afferent types are electrotonically compact and that excitatory postsynaptic potentials are two to four times larger in MES afferents than in other afferents, making MES afferents more responsive to low input levels. The models also predict that MES and LES terminal structures permit higher spontaneous firing rates than those in striola and juxtastriola. We found that differences in spike train regularity are not a consequence of differences in peripheral terminal structure, per se, but that a higher proportion of multiple contacts between afferents and individual hair cells increases afferent firing irregularity. The prediction that afferents having primarily one bouton contact per hair cell will fire more regularly than afferents making multiple bouton contacts per hair cell has implications for spike train regularity in dimorphic and calyx afferents. NEW & NOTEWORTHY Bouton afferents in different regions of turtle utricle have very different morphologies and afferent-hair cell connectivities. Highly detailed computational modeling provides insights into how morphology impacts excitability and also reveals a new explanation for spike train irregularity based on relative numbers of multiple bouton contacts per hair cell. This mechanism is independent of other proposed mechanisms for spike train irregularity based on ionic conductances and can explain irregularity in dimorphic units and calyx endings. Copyright © 2017 the American Physiological Society.
29 CFR Appendix A to Subpart L of... - Fire Protection
Code of Federal Regulations, 2014 CFR
2014-07-01
..., amount, and frequency of training and education will be as varied as are the purposes for which fire... should be qualified to train fire brigade members and demonstrate skills in communication, methods of... situations including “wet drills” and, when feasible, extinguishment of actual mock fires. Frequency of...
29 CFR Appendix A to Subpart L of... - Fire Protection
Code of Federal Regulations, 2012 CFR
2012-07-01
..., amount, and frequency of training and education will be as varied as are the purposes for which fire... should be qualified to train fire brigade members and demonstrate skills in communication, methods of... situations including “wet drills” and, when feasible, extinguishment of actual mock fires. Frequency of...
29 CFR Appendix A to Subpart L of... - Fire Protection
Code of Federal Regulations, 2011 CFR
2011-07-01
..., amount, and frequency of training and education will be as varied as are the purposes for which fire... should be qualified to train fire brigade members and demonstrate skills in communication, methods of... situations including “wet drills” and, when feasible, extinguishment of actual mock fires. Frequency of...
29 CFR Appendix A to Subpart L of... - Fire Protection
Code of Federal Regulations, 2013 CFR
2013-07-01
..., amount, and frequency of training and education will be as varied as are the purposes for which fire... should be qualified to train fire brigade members and demonstrate skills in communication, methods of... situations including “wet drills” and, when feasible, extinguishment of actual mock fires. Frequency of...
49 CFR 193.2717 - Training: fire protection.
Code of Federal Regulations, 2013 CFR
2013-10-01
... under § 193.2801. (b) A written plan of continuing instruction, including plant fire drills, must be... 49 Transportation 3 2013-10-01 2013-10-01 false Training: fire protection. 193.2717 Section 193...: fire protection. (a) All personnel involved in maintenance and operations of an LNG plant, including...
49 CFR 193.2717 - Training: fire protection.
Code of Federal Regulations, 2011 CFR
2011-10-01
... under § 193.2801. (b) A written plan of continuing instruction, including plant fire drills, must be... 49 Transportation 3 2011-10-01 2011-10-01 false Training: fire protection. 193.2717 Section 193...: fire protection. (a) All personnel involved in maintenance and operations of an LNG plant, including...
49 CFR 193.2717 - Training: fire protection.
Code of Federal Regulations, 2012 CFR
2012-10-01
... under § 193.2801. (b) A written plan of continuing instruction, including plant fire drills, must be... 49 Transportation 3 2012-10-01 2012-10-01 false Training: fire protection. 193.2717 Section 193...: fire protection. (a) All personnel involved in maintenance and operations of an LNG plant, including...
49 CFR 193.2717 - Training: fire protection.
Code of Federal Regulations, 2014 CFR
2014-10-01
... under § 193.2801. (b) A written plan of continuing instruction, including plant fire drills, must be... 49 Transportation 3 2014-10-01 2014-10-01 false Training: fire protection. 193.2717 Section 193...: fire protection. (a) All personnel involved in maintenance and operations of an LNG plant, including...
Skin antiseptics and the risk of operating theatre fires.
Spigelman, Allan D; Swan, Judith R
2005-07-01
Following press reports of patients catching fire or receiving chemical burns in the operating theatre, a review was conducted on the flammability of skin antiseptics. The purpose of the paper was to clarify confusion regarding povidine-iodine (Betadine), which had been reported as being flammable, and also to determine the use of alcohol-based solutions in the Hunter Area Health Service. A risk assessment was conducted and risk reduction strategies outlined. Risk assessment was made following a literature review and an audit of 10 operating theatres in the Hunter Area Health Service. Risk for operating room fires from alcohol-based skin antiseptics was confirmed. Antiseptics in aqueous solutions only smoulder. The Hunter Health survey indicated that although alcohol-based solutions were not used in operating theatres, they were used in anaesthetic bays for insertion of epidural and central line catheters. Strategies to reduce the risk of fire include discontinuation of use of alcohol-based skin antiseptics in operating theatres; using fire retardant surgical drapes; installing over-current protection devices on electrical equipment; minimizing flammable conditions by avoiding nitrous oxide and using the lowest required concentration of inspired oxygen; use of non-flammable cuffed endotracheal tubes; education and training of operating theatre personnel in fire hazards. Operating theatre fires continue to be a major risk for patient safety. In order to reduce this risk, the strategies outlined here should be followed.
An assessment of air quality impacts of fires associated with fire fighting operations.
Leahey, D M; Hansen, M C; Schroeder, M B
1993-03-01
Fire fighters in Canada's navy must undergo regular training with fires from simulated helicopter crashes. Visible emissions from these fires often create health concerns in surrounding communities. This paper presents air quality implications of plume dispersion associated with "helicopter fires." Evaluations involved measuring plume rise, estimating emissions, dispersion modeling and ambient monitoring. Results of the evaluation provided ground-level concentration estimates of plume particulate matter, oxides of nitrogen, hydrogen fluoride, carbon monoxide, 22 metals, 15 PAH and 13 VOC. The study showed that the air quality impact of the fire fighting training is much lower than the relevant time-weighted averages established to protect workers' health. This paper will be of interest to people in environmental protection agencies because it demonstrates the effects of fire fighting operations that must frequently occur as part of training exercises.
Stock, Matt S; Thompson, Brennan J
2014-01-01
Previous investigations that have studied motor unit firing rates following strength training have been limited to small muscles, isometric training, or interventions involving exercise machines. We examined the effects of ten weeks of supervised barbell deadlift training on motor unit firing rates for the vastus lateralis and rectus femoris during a 50% maximum voluntary contraction (MVC) assessment. Twenty-four previously untrained men (mean age = 24 years) were randomly assigned to training (n = 15) or control (n = 9) groups. Before and following the intervention, the subjects performed isometric testing of the right knee extensors while bipolar surface electromyographic signals were detected from the two muscles. The signals were decomposed into their constituent motor unit action potential trains, and motor units that demonstrated accuracy levels less than 92.0% were not considered for analysis. One thousand eight hundred ninety-two and 2,013 motor units were examined for the vastus lateralis and rectus femoris, respectively. Regression analyses were used to determine the linear slope coefficients (pulses per second [pps]/% MVC) and y-intercepts (pps) of the mean firing rate and firing rate at recruitment versus recruitment threshold relationships. Deadlift training significantly improved knee extensor MVC force (Cohen's d = .70), but did not influence force steadiness. Training had no influence on the slopes and y-intercepts for the mean firing rate and firing rate at recruitment versus recruitment threshold relationships. In agreement with previous cross-sectional comparisons and randomized control trials, our findings do not support the notion that strength training affects the submaximal control of motor units.
Saliency Detection and Deep Learning-Based Wildfire Identification in UAV Imagery.
Zhao, Yi; Ma, Jiale; Li, Xiaohui; Zhang, Jie
2018-02-27
An unmanned aerial vehicle (UAV) equipped with global positioning systems (GPS) can provide direct georeferenced imagery, mapping an area with high resolution. So far, the major difficulty in wildfire image classification is the lack of unified identification marks, the fire features of color, shape, texture (smoke, flame, or both) and background can vary significantly from one scene to another. Deep learning (e.g., DCNN for Deep Convolutional Neural Network) is very effective in high-level feature learning, however, a substantial amount of training images dataset is obligatory in optimizing its weights value and coefficients. In this work, we proposed a new saliency detection algorithm for fast location and segmentation of core fire area in aerial images. As the proposed method can effectively avoid feature loss caused by direct resizing; it is used in data augmentation and formation of a standard fire image dataset 'UAV_Fire'. A 15-layered self-learning DCNN architecture named 'Fire_Net' is then presented as a self-learning fire feature exactor and classifier. We evaluated different architectures and several key parameters (drop out ratio, batch size, etc.) of the DCNN model regarding its validation accuracy. The proposed architecture outperformed previous methods by achieving an overall accuracy of 98%. Furthermore, 'Fire_Net' guarantied an average processing speed of 41.5 ms per image for real-time wildfire inspection. To demonstrate its practical utility, Fire_Net is tested on 40 sampled images in wildfire news reports and all of them have been accurately identified.
STS-47 crew participates in fire fighting exercises at JSC Fire Training Pit
NASA Technical Reports Server (NTRS)
1992-01-01
STS-47 Endeavour, Orbiter Vehicle (OV) 105, Mission Specialist (MS) N. Jan Davis (foreground) and MS and Payload Commander (PLC) Mark C. Lee, squinting and holding water hose, listen to instructions prior to participating in fire fighting exercises held at JSC's Fire Training Pit across from Gilruth Center Bldg 207.
Model Training Guide. Firefighter I.
ERIC Educational Resources Information Center
Hagevig, William A.; Gallagher, Leigh S.
This firefighter training guide for a 180-hour course was developed to assist training officers in planning training with emphasis on conformance to recommended National Fire Protection Association (NFPA 1001) standards. The material in the guide is referenced to current editions of the International Fire Service Training Association manuals and…
Simulating the effect of ignition source type on forest fire statistics
NASA Astrophysics Data System (ADS)
Krenn, Roland; Hergarten, Stefan
2010-05-01
Forest fires belong to the most frightening natural hazards, and have long-term ecological and economic effects on the regions involved. It was found that their frequency-area distributions show power-law behaviour under a wide variety of conditions, interpreting them as a self-organised critical phenomenon. Using computer simulations, self-organised critical behaviour manifests in simple cellular automaton models. With respect to ignition source, forest fires can be categorised as lightning-induced or as a result of human activity. Lightning fires are considered to be natural, whereas ``man made'' fires are frequently caused by some sort of technological disaster, such as sparks from wheels of trains, the rupture of overhead electrical lines, the misuse of electrical or mechanical devices and so on. Taking into account that such events rarely occur deep in the woods, man made fires should start preferably on the edge of a forest or where the forest is not very dense. We present a modification in the self-organised critical Drossel-Schwabl forest fire model that takes these two different triggering mechanisms into account and increases the scaling exponent of the frequency-area distribution by ca. 1/3. Combined simulations further predict a dependence of the overall event-size distribution on the ratio of lightning-induced and man made fires as well as a splitting of their partial distributions. Lightning is identified as the dominant mechanism in the regime of the largest fires. The results are confirmed by the analysis of the Canadian Large Fire Database and suggest that lightning-induced and man made forest fires cannot be treated separately in wildfire modelling, hazard assessment and forest management.
Influence of military activities on raptor abundance and behavior
Schueck, Linda S.; Marzluff, J.M.; Steenhof, Karen
2001-01-01
We investigated the influence of military training on the abundance and behavior of raptors at a military training area in the Snake River Birds of Prey National Conservation Area in Idaho during the breeding seasons of 1991a??1994. Raptor counts on military training ranges did not differ when we compared all training days to all non-training days. However, during one period of intensive military training in one breeding season, raptor counts were lower during training than on non-training days. During training, Northern Harriers (Circus cyaneus) did not alter their behavior on training days. In years when prey numbers were low, falcons, hawks, and eagles perched and flew at low levels less often and flew at higher altitudes more often during training than they did when training did not occur. We observed fewer prey capture attempts on ranges on days with training than on days without training. Specific types of military training activity affected counts of raptors on ranges. The lowest raptor counts were associated with firing of artillery, small arms, and main turret guns or machine guns on tanks. Raptor counts associated with tank preparation (i.e., assembling and loading ammunition), driving, laser training, and convoy traffic were similar to non-training periods.
2006-03-01
Figure 25. Undecorated and decorated rim sherds from 3 1HK695 52 Figure 26. Decorated porcelain cup sherds from 3 1HK695 52 Figure 27. Decorated...pressed-glass sherd and medicine/bitters bottle neck from 3 1HK695 52 Figure 28. Bisque-fired porcelain doll sherd and Prosser type buttons from 3 1HK695...quartz that varies in quality, color and crystalline structure. A single bipolar core fragment of crystal "smoky" quartz was found on the surface in
Chen, Jessie; Reitzen, Shari D; Kohlenstein, Jane B; Gardner, Esther P
2009-12-01
Studies of hand manipulation neurons in posterior parietal cortex of monkeys suggest that their spike trains represent objects by the hand postures needed for grasping or by the underlying patterns of muscle activation. To analyze the role of hand kinematics and object properties in a trained prehension task, we correlated the firing rates of neurons in anterior area 5 with hand behaviors as monkeys grasped and lifted knobs of different shapes and locations in the workspace. Trials were divided into four classes depending on the approach trajectory: forward, lateral, and local approaches, and regrasps. The task factors controlled by the animal-how and when he used the hand-appeared to play the principal roles in modulating firing rates of area 5 neurons. In all, 77% of neurons studied (58/75) showed significant effects of approach style on firing rates; 80% of the population responded at higher rates and for longer durations on forward or lateral approaches that included reaching, wrist rotation, and hand preshaping prior to contact, but only 13% distinguished the direction of reach. The higher firing rates in reach trials reflected not only the arm movements needed to direct the hand to the target before contact, but persisted through the contact, grasp, and lift stages. Moreover, the approach style exerted a stronger effect on firing rates than object features, such as shape and location, which were distinguished by half of the population. Forty-three percent of the neurons signaled both the object properties and the hand actions used to acquire them. However, the spread in firing rates evoked by each knob on reach and no-reach trials was greater than distinctions between different objects grasped with the same approach style. Our data provide clear evidence for synergies between reaching and grasping that may facilitate smooth, coordinated actions of the arm and hand.
Analysis of Idaho fire service education
NASA Astrophysics Data System (ADS)
Roberts, Walter O.
1999-01-01
Becoming a career fire fighter in the state of Idaho requires specialized knowledge and training. Fire science education at Idaho colleges and universities is available only to people who are affiliated with a fire department. Law enforcement curriculum, on the other hand, is available to any interested persons. A student in law enforcement can attend the Police Officers Standards and Training (POST) academy or participate in classes in one of Idaho's institutions for higher education. There are no fire academies in Idaho. Applicants wanting to become professional fire fighters in Idaho are required to compete with applicants from other states; many of whom have had prior fire education and training. Resident Idaho fire fighter applicants are at a disadvantage when applying for Idaho fire fighting positions. Because of this apparent need, I surveyed the Idaho fire chiefs, using a research instrument I developed in a graduate field research class. I wrote the research instrument to determine the educational needs of the Idaho fire service. The College of Southern Idaho (CSI) and the Idaho Fire Chiefs Association (IFCA) were the recipients of this survey. This report, Analysis of Idaho Fire Service Education, describes that research process from beginning to end.
Stock, Matt S.; Thompson, Brennan J.
2014-01-01
Previous investigations that have studied motor unit firing rates following strength training have been limited to small muscles, isometric training, or interventions involving exercise machines. We examined the effects of ten weeks of supervised barbell deadlift training on motor unit firing rates for the vastus lateralis and rectus femoris during a 50% maximum voluntary contraction (MVC) assessment. Twenty-four previously untrained men (mean age = 24 years) were randomly assigned to training (n = 15) or control (n = 9) groups. Before and following the intervention, the subjects performed isometric testing of the right knee extensors while bipolar surface electromyographic signals were detected from the two muscles. The signals were decomposed into their constituent motor unit action potential trains, and motor units that demonstrated accuracy levels less than 92.0% were not considered for analysis. One thousand eight hundred ninety-two and 2,013 motor units were examined for the vastus lateralis and rectus femoris, respectively. Regression analyses were used to determine the linear slope coefficients (pulses per second [pps]/% MVC) and y-intercepts (pps) of the mean firing rate and firing rate at recruitment versus recruitment threshold relationships. Deadlift training significantly improved knee extensor MVC force (Cohen's d = .70), but did not influence force steadiness. Training had no influence on the slopes and y-intercepts for the mean firing rate and firing rate at recruitment versus recruitment threshold relationships. In agreement with previous cross-sectional comparisons and randomized control trials, our findings do not support the notion that strength training affects the submaximal control of motor units. PMID:25531294
1987-01-01
or C, where military training is intense. A lot of species (Stonechat, Tree pipit, Wheatear, Linnet, Yellowhammer, Woodiar’, Willow warb-er, Great tit...no: P•a ’fully legible lajury to game tarough firing or vohic•a traffii seldon happona e.gnd biars no relaticn to that whiet ta.os place outioide of
Firefighters from Mayport Naval Station train at CCAFS
NASA Technical Reports Server (NTRS)
2000-01-01
Firefighters in full gear douse a fire on a simulated aircraft. The firefighters, who are with Fire and Emergency Services at the Naval Station Mayport, Fla., are taking part in fire training exercises at Cape Canaveral Air Force Station Pad 30.
Prediction suppression and surprise enhancement in monkey inferotemporal cortex.
Ramachandran, Suchitra; Meyer, Travis; Olson, Carl R
2017-07-01
Exposing monkeys, over the course of days and weeks, to pairs of images presented in fixed sequence, so that each leading image becomes a predictor for the corresponding trailing image, affects neuronal visual responsiveness in area TE. At the end of the training period, neurons respond relatively weakly to a trailing image when it appears in a trained sequence and, thus, confirms prediction, whereas they respond relatively strongly to the same image when it appears in an untrained sequence and, thus, violates prediction. This effect could arise from prediction suppression (reduced firing in response to the occurrence of a probable event) or surprise enhancement (elevated firing in response to the omission of a probable event). To identify its cause, we compared firing under the prediction-confirming and prediction-violating conditions to firing under a prediction-neutral condition. The results provide strong evidence for prediction suppression and limited evidence for surprise enhancement. NEW & NOTEWORTHY In predictive coding models of the visual system, neurons carry signed prediction error signals. We show here that monkey inferotemporal neurons exhibit prediction-modulated firing, as posited by these models, but that the signal is unsigned. The response to a prediction-confirming image is suppressed, and the response to a prediction-violating image may be enhanced. These results are better explained by a model in which the visual system emphasizes unpredicted events than by a predictive coding model. Copyright © 2017 the American Physiological Society.
The Potential for Restoration to Break the Grass/Fire Cycle in Dryland Ecosystems in Hawaii
2016-11-01
Content of a Leaf PSAG Pleistocene Substrate Age Gradient PSW Pacific Southwest Station PTA Pohakuloa Training Area PV Photosynthetic Vegetation...resampled these images to 1.5 m resolution, and the study area encompassed 23 individual photographs. Due to variable solar illumination among...ecosystems many plant species benefit from similar conditions during regeneration, such as increased water availability, decreased solar radiation, and
78 FR 65678 - Assistance to Firefighters Grant Program
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-01
... (EMS) organizations, and state fire training academies for the purpose of enhancing the abilities of... medical services (EMS) organizations, and State Fire Training Academies (SFTAs) to enhance their ability.... Emergency Medical Services Providers: Fire departments and nonaffiliated EMS organizations; not less than 3...
NASA Astrophysics Data System (ADS)
Giannakopoulos, Christos; Karali, Anna; Roussos, Anargyros
2014-05-01
Greece, being part of the eastern Mediterranean basin, is an area particularly vulnerable to climate change and associated forest fire risk. The aim of this study is to assess the vulnerability of Greek forests to fire risk occurrence and identify potential adaptation options within the context of climate change through continuous interaction with local stakeholders. To address their needs, the following tools for the provision of climate information services were developed: 1. An application providing fire risk forecasts for the following 3 days (http://cirrus.meteo.noa.gr/forecast/bolam/index.htm) was developed from NOA to address the needs of short term fire planners. 2. A web-based application providing long term fire risk and other fire related indices changes due to climate change (time horizon up to 2050 and 2100) was developed in collaboration with the WWF Greece office to address the needs of long term fire policy makers (http://www.oikoskopio.gr/map/). 3. An educational tool was built in order to complement the two web-based tools and to further expand knowledge in fire risk modeling to address the needs for in-depth training. In particular, the second product provided the necessary information to assess the exposure to forest fires. To this aim, maps depicting the days with elevated fire risk (FWI>30) both for the control (1961-1990) and the near future period (2021-2050) were created by the web-application. FWI is a daily index that provides numerical ratings of relative fire potential based solely on weather observations. The meteorological inputs to the FWI System are daily noon values of temperature, air relative humidity, 10m wind speed and precipitation during the previous 24 hours. It was found that eastern lowlands are more exposed to fire risk followed by eastern high elevation areas, for both the control and near future period. The next step towards vulnerability assessment was to address sensitivity, ie the human-environmental conditions that can worsen or ameliorate the hazard. In our study static information concerning fire affecting factors, namely the topography and vegetation, was used to create a fire hazard map in order to assess the sensitivity factor. Land cover types for the year 2007 were combined with topographic information deriving from a digital elevation model order to produce these maps. High elevation continental areas were found to be the most sensitive areas followed by the lowland continental areas. Exposure and sensitivity were combined to produce the overall impact of climate change to forest fire risk. The adaptive capacity is defined by the ability of forests to adapt to changing environmental conditions. To assess the adaptive capacity of Greek forests, a Multi-Criteria Analysis (MCA) tool was implemented and used by the stakeholders. The major proposed adaptation measures for Greek forests included fire prevention measures and the inclusion of the private forest covered areas in the fire fighting. Finally, vulnerability of Greek forest to fire was estimated as the overall impact of climate change minus the forests' adaptive capacity and was found to be medium for most areas in the country. Acknowledgement: This work was supported by the EU project CLIM-RUN under contract FP7-ENV-2010-265192.
Integrating remote sensing and terrain data in forest fire modeling
NASA Astrophysics Data System (ADS)
Medler, Michael Johns
Forest fire policies are changing. Managers now face conflicting imperatives to re-establish pre-suppression fire regimes, while simultaneously preventing resource destruction. They must, therefore, understand the spatial patterns of fires. Geographers can facilitate this understanding by developing new techniques for mapping fire behavior. This dissertation develops such techniques for mapping recent fires and using these maps to calibrate models of potential fire hazards. In so doing, it features techniques that strive to address the inherent complexity of modeling the combinations of variables found in most ecological systems. Image processing techniques were used to stratify the elements of terrain, slope, elevation, and aspect. These stratification images were used to assure sample placement considered the role of terrain in fire behavior. Examination of multiple stratification images indicated samples were placed representatively across a controlled range of scales. The incorporation of terrain data also improved preliminary fire hazard classification accuracy by 40%, compared with remotely sensed data alone. A Kauth-Thomas transformation (KT) of pre-fire and post-fire Thematic Mapper (TM) remotely sensed data produced brightness, greenness, and wetness images. Image subtraction indicated fire induced change in brightness, greenness, and wetness. Field data guided a fuzzy classification of these change images. Because fuzzy classification can characterize a continuum of a phenomena where discrete classification may produce artificial borders, fuzzy classification was found to offer a range of fire severity information unavailable with discrete classification. These mapped fire patterns were used to calibrate a model of fire hazards for the entire mountain range. Pre-fire TM, and a digital elevation model produced a set of co-registered images. Training statistics were developed from 30 polygons associated with the previously mapped fire severity. Fuzzy classifications of potential burn patterns were produced from these images. Observed field data values were displayed over the hazard imagery to indicate the effectiveness of the model. Areas that burned without suppression during maximum fire severity are predicted best. Areas with widely spaced trees and grassy understory appear to be misrepresented, perhaps as a consequence of inaccuracies in the initial fire mapping.
Firefighters from Mayport Naval Station train at CCAFS
NASA Technical Reports Server (NTRS)
2000-01-01
A Mobile Aircraft Fire Trainer vehicle from Naval Station Mayport, Fla., stands by during fire training exercises at Cape Canaveral Air Force Station Pad 30. In the background is the simulated aircraft that was set on fire for the exercise. Firefighters with the Fire and Emergency Services at the Naval Station (in the background) gather around the site of the extinguished flames.
75 FR 44720 - Safety Zone; Live-Fire Gun Exercise, M/V Del Monte, James River, VA
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-29
...-AA00 Safety Zone; Live-Fire Gun Exercise, M/V Del Monte, James River, VA AGENCY: Coast Guard, DHS... mariners from the hazards associated with live fire and explosive training events. DATES: This rule is... Hampton Roads was notified that the U.S. Navy will conduct a live fire and explosive training event...
STS-47 crew during JSC fire fighting exercises in the Fire Training Pit
NASA Technical Reports Server (NTRS)
1992-01-01
STS-47 Endeavour, Orbiter Vehicle (OV) 105, crewmembers line up along water hoses during JSC fire fighting exercises held at JSC's Fire Training Pit. In the foreground are (left to right) Pilot Curtis L. Brown, Jr, holding the hose nozzle, Mission Specialist (MS) N. Jan Davis, MS and Payload Commander (PLC) Mark C. Lee, and backup Payload Specialist Stan Koszelak, partially visible at the end of the line. In the background, manning a second hose are backup Payload Specialist Takao Doi, MS Jerome Apt, and Commander Robert L. Gibson. A veteran fire fighter (behind Brown) stands between the two hoses giving instructions. The Fire Training Pit is located across from the Gilruth Center Bldg 207. Doi represents Japan's National Space Development Agency (NASDA).
Saliency Detection and Deep Learning-Based Wildfire Identification in UAV Imagery
Zhao, Yi; Ma, Jiale; Li, Xiaohui
2018-01-01
An unmanned aerial vehicle (UAV) equipped with global positioning systems (GPS) can provide direct georeferenced imagery, mapping an area with high resolution. So far, the major difficulty in wildfire image classification is the lack of unified identification marks, the fire features of color, shape, texture (smoke, flame, or both) and background can vary significantly from one scene to another. Deep learning (e.g., DCNN for Deep Convolutional Neural Network) is very effective in high-level feature learning, however, a substantial amount of training images dataset is obligatory in optimizing its weights value and coefficients. In this work, we proposed a new saliency detection algorithm for fast location and segmentation of core fire area in aerial images. As the proposed method can effectively avoid feature loss caused by direct resizing; it is used in data augmentation and formation of a standard fire image dataset ‘UAV_Fire’. A 15-layered self-learning DCNN architecture named ‘Fire_Net’ is then presented as a self-learning fire feature exactor and classifier. We evaluated different architectures and several key parameters (drop out ratio, batch size, etc.) of the DCNN model regarding its validation accuracy. The proposed architecture outperformed previous methods by achieving an overall accuracy of 98%. Furthermore, ‘Fire_Net’ guarantied an average processing speed of 41.5 ms per image for real-time wildfire inspection. To demonstrate its practical utility, Fire_Net is tested on 40 sampled images in wildfire news reports and all of them have been accurately identified. PMID:29495504
Kim, J H; Ohara, S; Lenz, F A
2009-04-01
Primate thalamic action potential bursts associated with low-threshold spikes (LTS) occur during waking sensory and motor activity. We now test the hypothesis that different firing and LTS burst characteristics occur during quiet wakefulness (spontaneous condition) versus mental arithmetic (counting condition). This hypothesis was tested by thalamic recordings during the surgical treatment of tremor. Across all neurons and epochs, preburst interspike intervals (ISIs) were bimodal at median values, consistent with the duration of type A and type B gamma-aminobutyric acid inhibitory postsynaptic potentials. Neuronal spike trains (117 neurons) were categorized by joint ISI distributions into those firing as LTS bursts (G, grouped), firing as single spikes (NG, nongrouped), or firing as single spikes with sporadic LTS bursting (I, intermediate). During the spontaneous condition (46 neurons) only I spike trains changed category. Overall, burst rates (BRs) were lower and firing rates (FRs) were higher during the counting versus the spontaneous condition. Spike trains in the G category sometimes changed to I and NG categories at the transition from the spontaneous to the counting condition, whereas those in the I category often changed to NG. Among spike trains that did not change category by condition, G spike trains had lower BRs during counting, whereas NG spike trains had higher FRs. BRs were significantly greater than zero for G and I categories during wakefulness (both conditions). The changes between the spontaneous and counting conditions are most pronounced for the I category, which may be a transitional firing pattern between the bursting (G) and relay modes of thalamic firing (NG).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Denise Baclawski
2010-03-08
The University of Nevada, Reno Fire Science Academy (FSA) applied for grant funding to develop and deliver programs for municipal, rural, and volunteer firefighters. The FSA specializes in preparing responders for a variety of emergency events, including flammable liquid fires resulting from accidents, intentional acts, or natural disasters. Live fire training on full scale burnable props is the hallmark of FSA training, allowing responders to practice critical skills in a realistic, yet safe environment. Unfortunately, flammable liquid live fire training is often not accessible to municipal, rural, or volunteer firefighters due to limited department training budgets, even though most departmentmore » personnel will be exposed to flammable liquid fire incidents during the course of their careers. In response to this training need, the FSA developed a course during the first year of the grant (Year One), Responding to Terrorist Incidents in Your Community: Flammable-Liquid Fire Fighting Techniques for Municipal and Rural Firefighters. During the three years of the grant, a total of 2,029 emergency responders received this training. In Year Three, two new courses, a train-the-trainer for Responding to Terrorist Incidents in Your Community and Management of Large-Scale Disasters for Public Officials were developed and pilot tested during the Real-World Disaster Management Conference held at the FSA in June of 2007. Two research projects were conducted during Years Two and Three. The first, conducted over a two year period, evaluated student surveys regarding the value of the flammable liquids training received. The second was a needs assessment conducted for rural Nevada. Both projects provided important feedback and a basis for curricula development and improvements.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1999-03-01
This decision document presents the Air Force Center for Environmental Excellence (AFCEE) selected remedial action decisions for contaminant source areas at the following Areas of Contamination (AOCs) at the Massachusetts Military Reservation (MMR) in Barnstable County on Cape Cod, Massachusetts: Fire Training Area No. 2 and Landfill No. 2 (FTA-2/LF-2); Petroleum Fuels Storage Area, Fuel Spill No. 10, and Fuel Spill No. 11 (PFSA/FS-10/FS-11); Storm Drainage Ditch No. 2, Fuel Spill No. 6, and Fuel Spill No. 8 (SD-2/FS-6/FS-8); Storm Drainage Ditch No. 2, Fire Training Area No. 3, and Coal Storage Yard No. 4 (SF-3/FTA-3/CY-4); Storm Drainage Ditch No.more » 4 (SD-4); and Storm Drainage Ditch No. 5 and Fuel Spill No. 5 (SD-5/FS-5). The selected remedy for AOC FTA-2/LF-2 is Biosparging with Ambient Air Monitoring. This remedial action is a source control action that addresses leaching of organic compounds to groundwater, the principal known threat at AOC FTA-2/LF-2. It consists of designing, constructing, and operating a biosparging treatment system, maintaining institutional controls, and five-year reviews of remedy protectiveness. The remedy reduces the release of contaminants from subsurface soils by treating subsurface soils to meet protective cleanup levels.« less
Gilson, Matthieu; Burkitt, Anthony N; Grayden, David B; Thomas, Doreen A; van Hemmen, J Leo
2009-12-01
In neuronal networks, the changes of synaptic strength (or weight) performed by spike-timing-dependent plasticity (STDP) are hypothesized to give rise to functional network structure. This article investigates how this phenomenon occurs for the excitatory recurrent connections of a network with fixed input weights that is stimulated by external spike trains. We develop a theoretical framework based on the Poisson neuron model to analyze the interplay between the neuronal activity (firing rates and the spike-time correlations) and the learning dynamics, when the network is stimulated by correlated pools of homogeneous Poisson spike trains. STDP can lead to both a stabilization of all the neuron firing rates (homeostatic equilibrium) and a robust weight specialization. The pattern of specialization for the recurrent weights is determined by a relationship between the input firing-rate and correlation structures, the network topology, the STDP parameters and the synaptic response properties. We find conditions for feed-forward pathways or areas with strengthened self-feedback to emerge in an initially homogeneous recurrent network.
Report on Technical Advisory Services. Fiscal Year 1965
1965-12-01
and train- ing problem areas depicted in movies of ET firings were reviewed . e. Visitors were provided information on requirementsfor a small tracking...Director’s Office from Division No. 1 served on a special Army committee to prepare an historical review of the training and use of marginnl personnel...Personnel: of. Smith. Capt. Shepherd (USN net.) Dotes: Sp-Doec 64 Days expentlef. 1 2ri ’-A ,,C VL 7. Assistance is being given in the review of Army
History of the 4th Battalion, 37th Armored Regiment in Operation Desert Shield/Storm. Volume 1
1992-04-15
find and unpack the MILVAN with his canvas inside. One of the big issues was our concern over the new model 900 series sabot ammunition. It was...Recommendations 3rd Brigade Change of Command Sand Storms Visit to Rear Assembly Area Huebner Live Fire Training Day-to-Day Business and...the S2. It consisted of model terrain boards of the battalion’s General Defense Plan (GDP) in the FRG, the National Training Center (NTC), and the
NASA Astrophysics Data System (ADS)
Tourigny, E.; Nobre, C.; Cardoso, M. F.
2012-12-01
Deforestation of tropical forests for logging and agriculture, associated to slash-and-burn practices, is a major source of CO2 emissions, both immediate due to biomass burning and future due to the elimination of a potential CO2 sink. Feedbacks between climate change and LUCC (Land-Use and Land-Cover Change) can potentially increase the loss of tropical forests and increase the rate of CO2 emissions, through mechanisms such as land and soil degradation and the increase in wildfire occurrence and severity. However, current understanding of the processes of fires (including ignition, spread and consequences) in tropical forests and climatic feedbacks are poorly understood and need further research. As the processes of LUCC and associated fires occur at local scales, linking them to large-scale atmospheric processes requires a means of up-scaling higher resolutions processes to lower resolutions. Our approach is to couple models which operate at various spatial and temporal scales: a Global Climate Model (GCM), Dynamic Global Vegetation Model (DGVM) and local-scale LUCC and fire spread model. The climate model resolves large scale atmospheric processes and forcings, which are imposed on the surface DGVM and fed-back to climate. Higher-resolution processes such as deforestation, land use management and associated (as well as natural) fires are resolved at the local level. A dynamic tiling scheme allows to represent local-scale heterogeneity while maintaining computational efficiency of the land surface model, compared to traditional landscape models. Fire behavior is modeled at the regional scale (~500m) to represent the detailed landscape using a semi-empirical fire spread model. The relatively coarse scale (as compared to other fire spread models) is necessary due to the paucity of detailed land-cover information and fire history (particularly in the tropics and developing countries). This work presents initial results of a spatially-explicit fire spread model coupled to the IBIS DGVM model. Our area of study comprises selected regions in and near the Brazilian "arc of deforestation". For model training and evaluation, several areas have been mapped using high-resolution imagery from the Landsat TM/ETM+ sensors (Figure 1). This high resolution reference data is used for local-scale simulations and also to evaluate the accuracy of the global MCD45 burned area product, which will be used in future studies covering the entire "arc of deforestation".; Area of study along the arc of deforestation and cerrado: landsat scenes used and burned area (2010) from MCD45 product.
Harrington, Susan S.; Walker, Bonnie L.
2010-01-01
Background Older adults in small residential board and care facilities are at a particularly high risk of fire death and injury because of their characteristics and environment. Methods The authors investigated computer-based instruction as a way to teach fire emergency planning to owners, operators, and staff of small residential board and care facilities. Participants (N = 59) were randomly assigned to a treatment or control group. Results Study participants who completed the training significantly improved their scores from pre- to posttest when compared to a control group. Participants indicated on the course evaluation that the computers were easy to use for training (97%) and that they would like to use computers for future training courses (97%). Conclusions This study demonstrates the potential for using interactive computer-based training as a viable alternative to instructor-led training to meet the fire safety training needs of owners, operators, and staff of small board and care facilities for the elderly. PMID:19263929
49 CFR 193.2717 - Training: fire protection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... their immediate supervisors, must be trained according to a written plan of initial instruction... under § 193.2801. (b) A written plan of continuing instruction, including plant fire drills, must be... personnel hands-on experience in carrying out their duties under the fire emergency procedures required by...
Identifying persistent and characteristic features in firearm tool marks on cartridge cases
NASA Astrophysics Data System (ADS)
Ott, Daniel; Soons, Johannes; Thompson, Robert; Song, John
2017-12-01
Recent concerns about subjectivity in forensic firearm identification have motivated the development of algorithms to compare firearm tool marks that are imparted on ammunition and to generate quantitative measures of similarity. In this paper, we describe an algorithm that identifies impressed tool marks on a cartridge case that are both consistent between firings and contribute strongly to a surface similarity metric. The result is a representation of the tool mark topography that emphasizes both significant and persistent features across firings. This characteristic surface map is useful for understanding the variability and persistence of the tool marks created by a firearm and can provide improved discrimination between the comparison scores of samples fired from the same firearm and the scores of samples fired from different firearms. The algorithm also provides a convenient method for visualizing areas of similarity that may be useful in providing quantitative support for visual comparisons by trained examiners.
Jones, R T; Kazdin, A E; Haney, J I
1981-01-01
A multifaceted behavioral program designed to teach emergency fire escape procedures to children was evaluated in a multiple-baseline design. Five children were trained to respond correctly to nine home emergency fire situations under simulated conditions. The situations and responses focused upon in training were identified by a social validation procedure involving consultation with several safety agencies, including the direct input of firefighters. Training, carried out in simulated bedrooms at school, resulted in significant improvements in both overt behavior and self-report of fire safety skills. The gains were maintained at a post-check assessment 2 weeks after training had been terminated. The results are discussed in relation both to the importance of social validation of targets and outcomes and the implications for further research in assessing and developing emergency response skills. PMID:7298537
Emergency Management Computer-Aided Trainer (EMCAT)
NASA Technical Reports Server (NTRS)
Rodriguez, R. C.; Johnson, R. P.
1986-01-01
The Emergency Management Computer-Aided Trainer (EMCAT) developed by Essex Corporation or NASA and the Federal Emergency Management Administration's (FEMA) National Fire Academy (NFA) is described. It is a computer based training system for fire fighting personnel. A prototype EMCAT system was developed by NASA first using video tape images and then video disk images when the technology became available. The EMCAT system is meant to fill the training needs of the fire fighting community with affordable state-of-the-art technologies. An automated real time simulation of the fire situation was needed to replace the outdated manual training methods currently being used. In order to be successful, this simulator had to provide realism, be user friendly, be affordable, and support multiple scenarios. The EMCAT system meets these requirements and therefore represents an innovative training tool, not only for the fire fighting community, but also for the needs of other disciplines.
Tactical Requirements for Peacekeeping Operations.
1985-12-02
is the slum area of Burj - Al -Barjneh, which houses Palestinian refugees and Shia Muslims. Sniper fire from ’o.- this area became one of the greatest...isolation and low target value of most outposts, the only organization that might benefit from attacking them would be radical Arab terrorists, either...prevention and treatment (1/2 hr) Navigate in a desert environment (8 hrs) CD training (16 hrs) Handling POW’s (1 hr) Arabic familiarization course (40 hrs
Firefighters from Mayport Naval Station train at CCAFS
NASA Technical Reports Server (NTRS)
2000-01-01
A training officer controls elements of a fire training exercise at Cape Canaveral Air Force Station Pad 30 for firefighters with Fire and Emergency Services at the Naval Station Mayport, Fla. The firefighters tackled flames from a burning simulated aircraft.
ERIC Educational Resources Information Center
New England Board of Higher Education, Wellesley, MA.
Issues in the improvement of training for fire fighters and officer personnel were taken up in ten symposium papers. Session 1 covered legal and other constraints that affect what a fire fighter should know; and current practices in volunteer, rural, and municipal fire fighter training in the United States. Papers from the other sessions dealt…
Millwright Apprenticeship. Related Training Modules. 1.1-1.8 Safety.
ERIC Educational Resources Information Center
Lane Community Coll., Eugene, OR.
This packet, part of the instructional materials for the Oregon apprenticeship program for millwright training, contains eight modules covering safety. The modules provide information on the following topics: general safety, hand tool safety, power tool safety, fire safety, hygiene, safety and electricity, types of fire and fire prevention, and…
Steenhof, Karen; Kochert, Michael N.; Carpenter, L.B.; Lehman, Robert N.
1999-01-01
We studied a nesting population of Prairie Falcons (Falco mexicanus) in the Snake River Birds of Prey National Conservation Area (NCA) from 1974-1997 to identify factors that influence abundance and reproduction. Our sampling period included two major droughts and associated crashes in Townsend's ground squirrel (Spermophilus townsendii) populations. The number of Prairie Falcon pairs found on long-term survey segments declined significantly from 1976-1997. Early declines were most severe at the eastern end of the NCA, where fires and agriculture have changed native shrubsteppe habitat. More recent declines occurred in the portion of canyon near the Orchard Training Area (OTA), where the Idaho Army National Guard conducts artillery firing and tank maneuvers. Overall Prairie Falcon reproductive rates were tied closely to annual indexes of ground squirrel abundance, but precipitation before and during the breeding season was related inversely to some measures of reproduction. Most reproductive parameters showed no significant trends over time, but during the 1990s, nesting success and productivity were lower in the stretch of canyon near the OTA than in adjacent areas. Extensive shrub loss, by itself, did not explain the pattern of declines in abundance and reproduction that we observed. Recent military training activities likely have interacted with fire and livestock grazing to create less than favorable foraging opportunities for Prairie Falcons in a large part of the NCA. To maintain Prairie Falcon populations in the NCA, managers should suppress wildfires, restore native plant communities, and regulate potentially incompatible land uses.
ERIC Educational Resources Information Center
Campbell, Clifton P.; Buchanan, Joseph P.
1977-01-01
Fire emergency preparedness measures to take to prevent school fires and to protect against injury and minimize damage when fire does occur are presented. Includes fire safety practices, extinguishers for different classes of fires and their use, and the need for fire safety training in schools. (MF)
46 CFR 166.15 - Training for maintenance of discipline; ship sanitation; fire and lifeboat drills.
Code of Federal Regulations, 2010 CFR
2010-10-01
...; fire and lifeboat drills. 166.15 Section 166.15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... maintenance of discipline; ship sanitation; fire and lifeboat drills. All students shall be trained to obey... the fundamentals of ship sanitation as prescribed by law and regulations, and shall be given intensive...
46 CFR 166.15 - Training for maintenance of discipline; ship sanitation; fire and lifeboat drills.
Code of Federal Regulations, 2014 CFR
2014-10-01
...; fire and lifeboat drills. 166.15 Section 166.15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... maintenance of discipline; ship sanitation; fire and lifeboat drills. All students shall be trained to obey... the fundamentals of ship sanitation as prescribed by law and regulations, and shall be given intensive...
46 CFR 166.15 - Training for maintenance of discipline; ship sanitation; fire and lifeboat drills.
Code of Federal Regulations, 2011 CFR
2011-10-01
...; fire and lifeboat drills. 166.15 Section 166.15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... maintenance of discipline; ship sanitation; fire and lifeboat drills. All students shall be trained to obey... the fundamentals of ship sanitation as prescribed by law and regulations, and shall be given intensive...
46 CFR 166.15 - Training for maintenance of discipline; ship sanitation; fire and lifeboat drills.
Code of Federal Regulations, 2012 CFR
2012-10-01
...; fire and lifeboat drills. 166.15 Section 166.15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... maintenance of discipline; ship sanitation; fire and lifeboat drills. All students shall be trained to obey... the fundamentals of ship sanitation as prescribed by law and regulations, and shall be given intensive...
46 CFR 166.15 - Training for maintenance of discipline; ship sanitation; fire and lifeboat drills.
Code of Federal Regulations, 2013 CFR
2013-10-01
...; fire and lifeboat drills. 166.15 Section 166.15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... maintenance of discipline; ship sanitation; fire and lifeboat drills. All students shall be trained to obey... the fundamentals of ship sanitation as prescribed by law and regulations, and shall be given intensive...
Sarnaik, Rashmi
2018-01-01
Neurons of the cerebellar nuclei (CbN), which generate cerebellar output, are inhibited by Purkinje cells. With extracellular recordings during voluntary locomotion in head-fixed mice, we tested how the rate and coherence of inhibition influence CbN cell firing and well-practiced movements. Firing rates of Purkinje and CbN cells were modulated systematically through the stride cycle (~200–300 ms). Optogenetically stimulating ChR2-expressing Purkinje cells with light steps or trains evoked either asynchronous or synchronous inhibition of CbN cells. Steps slowed CbN firing. Trains suppressed CbN cell firing less effectively, but consistently altered millisecond-scale spike timing. Steps or trains that perturbed stride-related modulation of CbN cell firing rates correlated well with irregularities of movement, suggesting that ongoing locomotion is sensitive to alterations in modulated CbN cell firing. Unperturbed locomotion continued more often during trains than steps, however, suggesting that stride-related modulation of CbN spiking is less readily disrupted by synchronous than asynchronous inhibition. PMID:29659351
Diekman, Shane; Huitric, Michele; Netterville, Linda
2010-01-01
This article describes the development of the Fire H.E.L.P. tool kit for training selected Meals On Wheels (MOW) staff in Texas to implement a fire safety program for homebound older adults. We used a formative evaluation approach during the tool kit's development, testing, and initial implementation stages. The tool kit includes instructional curricula on how to implement Fire H.E.L.P., a home assessment tool to determine a residence's smoke alarm needs, and fire safety educational materials. During the tool kit's pilot test, MOW participants showed enhanced fire safety knowledge and high levels of confidence about applying their newfound training skills. After the pilot test, MOW staff used the tool kit to conduct local training sessions, provide fire safety education, and install smoke alarms in the homes of older adults. We believe the approach used to develop this tool kit can be applied to education efforts for other, related healthy home topics.
STS-32 crewmembers use water hoses during fire fighting training at JSC
1989-09-22
STS-32 crewmembers use water hoses during fire fighting exercises at JSC's Fire Training Pit across from the Gilruth Center Bldg 207. Mission Specialist (MS) G. David Low with nozzle open directs water into the fire as fire/ security personnel coaches and instructs him on his attempt to extinguish the blaze. MS Bonnie J. Dunbar maneuvers the hose behind Low. A second group of crewmembers alongside Low and Dunbar, MS Marsha S. Ivins, holding hose nozzle, Commander Daniel C. Brandenstein, and Pilot James D. Wetherbee position themselves before opening hose nozzle.
STS-32 crewmembers use water hoses during fire fighting training at JSC
NASA Technical Reports Server (NTRS)
1989-01-01
STS-32 crewmembers use water hoses during fire fighting exercises at JSC's Fire Training Pit across from the Gilruth Center Bldg 207. Mission Specialist (MS) G. David Low with nozzle open directs water into the fire as fire/ security personnel coaches and instructs him on his attempt to extinguish the blaze. MS Bonnie J. Dunbar maneuvers the hose behind Low. A second group of crewmembers alongside Low and Dunbar, MS Marsha S. Ivins, holding hose nozzle, Commander Daniel C. Brandenstein, and Pilot James D. Wetherbee position themselves before opening hose nozzle.
Fire/security staff member instructs STS-29 crew on fire extinguisher usage
1988-12-06
S88-54948 (6 Dec 1988) --- The STS-29 crewmembers are trained in procedures to follow in the event of a fire with their spacecraft. Here, the crew is briefed on correct handling of the fire extinguisher by Robert Fife (far left) of NASA's fire and security staff. Pictured, left to right, are Astronauts John E. Blaha, pilot; Michael L. Coats, mission commander; Robert C. Springer, James F. Buchli and James P. Bagian, mission specialists. The training exercise took place on the northern end of the 1625-acre JSC facility.
Nursing home evacuation plans.
Castle, Nicholas G
2008-07-01
I examined evacuation plans from 2134 nursing homes and analyzed national data to determine the types of nursing homes cited for deficiencies in their evacuation plans. Evacuation plans were assessed according to criteria developed by an expert panel funded by the Office of the Inspector General. Deficiency citations came from the Online Survey, Certification, and Recording database, collected from 1997 to 2005. Four specific citations, for written emergency plans, staff training, written evacuation plans, and fire drills, were examined with multivariate logistic regression. Most plans had water supply provisions (96%). Only 31% specified an evacuation route. The rate of citations was relatively stable throughout the study period: each year approximately 0.6% of facilities were found to be deficient in written emergency plans, 2.1% in staff training, 1.2% in written evacuation plans, and 7.9% in fire drills. Some nursing homes need more specific evacuation plans. Water supply was the most and evacuation routes were the least well-addressed areas.
Mayer, John M; Nuzzo, James L
2015-01-01
Firefighting is a dangerous occupation with a high incidence of low back pain and injury. Abnormal back muscle function and morphology has been linked to low back pain and poor physical performance. The effect of exercise training on back muscle size and symmetry has not been investigated in firefighters. The purpose of this study was to assess the effect of worksite exercise training for eliciting lumbar multifidus muscle hypertrophy in firefighters. A cluster randomized controlled trial was conducted with healthy, career firefighters (n=64) from a medium-sized fire department. Participants were randomized by fire station to exercise training (n=36) (supervised back and core exercise performed on duty, 2X/week, 24 weeks) or control (n=28). The cross-sectional area (CSA) of the L4 and L5 lumbar multifidus muscle was assessed with ultrasonography at baseline and following the intervention. At 24 weeks, no significant differences were noted between the groups in the adjusted (by baseline scores and body mass) L4 and L5 lumbar multifidus muscle CSA and asymmetry values. A worksite exercise training program targeting the back and core is not effective for eliciting hypertrophy of the lumbar multifidus muscle in healthy firefighters.
Requirements and Regulations for Open Burning and Fire Training
Intentional burning of facilities is considered demolition under federal asbestos regulations, even if no asbestos is present. Learn about regulations and requirements for open burning and fire training.
Hazardous materials responses in a mid-sized metropolitan area.
Walter, Frank G; Bates, Gerry; Criss, Elizabeth A; Bey, Tareg; Spaite, Daniel W; Valenzuela, Terence
2003-01-01
To determine the chemicals involved in fire department hazardous materials (hazmat) responses and analyze the concomitant emergency medical services' patient care needs. The setting was a mid-sized metropolitan area in the southwestern United States with a population base of 400,000 and an incorporated area of 165 square miles. The authors conducted a retrospective evaluation of all fire department hazmat reports, with associated emergency medical services patient encounter forms, and in-patient hospital records from January 1, 1992, through December 31, 1994. The fire department hazardous materials control team responded to 468 hazmat incidents, involving 62 chemicals. The majority of incidents occurred on city streets, with a mean incident duration of 46 minutes. More than 70% of the responses involved flammable gases or liquids. A total of 32 incidents generated 85 patients, 53% of whom required transport for further evaluation and care. Most patients were exposed to airborne toxicants. Only two patients required hospital admission for carbon monoxide poisoning. Most hazmat incidents result in few exposed patients who require emergency medical services care. Most patients were exposed to airborne toxicants and very few required hospitalization. Routine data analysis such as this provides emergency response personnel with the opportunity to evaluate current emergency plans and identify areas where additional training may be necessary.
ERIC Educational Resources Information Center
Florida State Dept. of Education, Tallahassee. Div. of Vocational, Adult, and Community Education.
Florida's community college and school district postsecondary adult vocational programs in fire fighter training and fire science technology were subjected to a statewide program review. Efforts were made to reach Florida's entire community of career and volunteer fire fighters. Data were collected in the following ways: site interviews with…
Fire fighters as basic life support responders: a study of successful implementation.
Høyer, Christian Bjerre; Christensen, Erika Frischknecht
2009-04-02
First responders are recommended as a supplement to the Emergency Medical Services (EMS) in order to achieve early defibrillation. Practical and organisational aspects are essential when trying to implement new parts in the "Chain of Survival"; areas to address include minimizing dispatch time, ensuring efficient and quick communication, and choosing areas with appropriate driving distances. The aim of this study was to implement a system using Basic Life Support (BLS) responders equipped with an automatic external defibrillator in an area with relatively short emergency medical services' response times. Success criteria for implementation was defined as arrival of the BLS responders before the EMS, attachment (and use) of the AED, and successful defibrillation. This was a prospective observational study from September 1, 2005 to December 31, 2007 (28 months) in the city of Aarhus, Denmark. The BLS responder system was implemented in an area up to three kilometres (driving distance) from the central fire station, encompassing approximately 81,500 inhabitants. The team trained on each shift and response times were reduced by choice of area and by sending the alarm directly to the fire brigade dispatcher. The BLS responders had 1076 patient contacts. The median response time was 3.5 minutes (25th percentile 2.75, 75th percentile 4.25). The BLS responders arrived before EMS in 789 of the 1076 patient contacts (73%). Cardiac arrest was diagnosed in 53 cases, the AED was attached in 29 cases, and a shockable rhythm was detected in nine cases. Eight were defibrillated using an AED. Seven of the eight obtained return of spontaneous circulation (ROSC). Six of the seven obtaining ROSC survived more than 30 days. In this study, the implementation of BLS responders may have resulted in successful resuscitations. On basis of the close corporation between all participants in the chain of survival this project contributed to the first link: short response time and trained personnel to ensure early defibrillation.
Fire fighters as basic life support responders: A study of successful implementation
Høyer, Christian Bjerre; Christensen, Erika Frischknecht
2009-01-01
Background First responders are recommended as a supplement to the Emergency Medical Services (EMS) in order to achieve early defibrillation. Practical and organisational aspects are essential when trying to implement new parts in the "Chain of Survival"; areas to address include minimizing dispatch time, ensuring efficient and quick communication, and choosing areas with appropriate driving distances. The aim of this study was to implement a system using Basic Life Support (BLS) responders equipped with an automatic external defibrillator in an area with relatively short emergency medical services' response times. Success criteria for implementation was defined as arrival of the BLS responders before the EMS, attachment (and use) of the AED, and successful defibrillation. Methods This was a prospective observational study from September 1, 2005 to December 31, 2007 (28 months) in the city of Aarhus, Denmark. The BLS responder system was implemented in an area up to three kilometres (driving distance) from the central fire station, encompassing approximately 81,500 inhabitants. The team trained on each shift and response times were reduced by choice of area and by sending the alarm directly to the fire brigade dispatcher. Results The BLS responders had 1076 patient contacts. The median response time was 3.5 minutes (25th percentile 2.75, 75th percentile 4.25). The BLS responders arrived before EMS in 789 of the 1076 patient contacts (73%). Cardiac arrest was diagnosed in 53 cases, the AED was attached in 29 cases, and a shockable rhythm was detected in nine cases. Eight were defibrillated using an AED. Seven of the eight obtained return of spontaneous circulation (ROSC). Six of the seven obtaining ROSC survived more than 30 days. Conclusion In this study, the implementation of BLS responders may have resulted in successful resuscitations. On basis of the close corporation between all participants in the chain of survival this project contributed to the first link: short response time and trained personnel to ensure early defibrillation. PMID:19341457
Intelligent Conduct of Fire Trainer: Intelligent Technology Applied to Simulator-Based Training.
ERIC Educational Resources Information Center
Newman, Denis; And Others
1989-01-01
Describes an intelligent tutoring system (ITS) that demonstrates how intelligent feedback can enhance conventional simulation-based training. An explanation is given of the Intelligent Conduct of Fire Trainer (INCOFT), which was designed to provide training exercises for soldiers operating the PATRIOT missile system, and its implications for…
46 CFR 12.602 - Basic training.
Code of Federal Regulations, 2014 CFR
2014-10-01
...) Swimming while wearing a lifejacket. (v) Keeping afloat without a lifejacket. (2) Fire prevention and... extinguishers. (ii) Extinguishing smaller fires. e.g., electrical fires, oil fires, and propane fires. (iii... firefighting agent in an accommodation room or simulated engine room with fire and heavy smoke. (vii...
An Implementing Strategy for Improving Wildland Fire Environmental Literacy
NASA Astrophysics Data System (ADS)
McCalla, M. R.; Andrus, D.; Barnett, K.
2007-12-01
Wildland fire is any planned or unplanned fire which occurs in wildland ecosystems. Wildland fires affect millions of acres annually in the U.S. An average of 5.4 million acres a year were burned in the U.S. between 1995 and 2004, approximately 142 percent of the average burned area between 1984 and 1994. In 2005 alone, Federal agencies spent nearly $1 billion on fire suppression and state and local agencies contributed millions more. Many Americans prefer to live and vacation in relatively remote surroundings, (i.e., woods and rangelands). These choices offer many benefits, but they also present significant risks. Most of North America is fire-prone and every day developed areas and home sites are extending further into natural wildlands, which increases the chances of catastrophic fire. In addition, an abundance of accumulated biomass in forests and rangelands and persistent drought conditions are contributing to larger, costlier wildland fires. To effectively prevent, manage, suppress, respond to, and recover from wildland fires, fire managers, and other communities which are impacted by wildland fires (e.g., the business community; healthcare providers; federal, state, and local policymakers; the media; the public, etc.) need timely, accurate, and detailed wildland fire weather and climate information to support their decision-making activities. But what are the wildland fire weather and climate data, products, and information, as well as information dissemination technologies, needed to reach out and promote wildland fire environmental literacy in these communities? The Office of the Federal Coordinator for Meteorological Services and Supporting Research (OFCM) conducted a comprehensive review and assessment of weather and climate needs of providers and users in their wildland fire and fuels management activities. The assessment has nine focus areas, one of which is environmental literacy (e.g., education, training, outreach, partnering, and collaboration). The OFCM model for promoting wildland fire environmental literacy, the model's component parts, as well as an implementing strategy to execute the model will be presented. That is, the presentation will lay out the framework and methodology which the OFCM used to systematically define the wildland fire weather and climate education and outreach needs through interdepartmental collaboration within the OFCM coordinating infrastructure. A key element of the methodology is to improve the overall understanding and use of wildland fire forecast and warning climate and weather products and to exploit current and emerging technologies to improve the dissemination of customer-tailored forecast and warning information and products to stakeholders and users. Thus, the framework and methodology define the method used to determine the target public, private, and academic sector audiences. The methodology also identifies the means for determining the optimal channels, formats, and content for informing end users in time for effective action to be taken.
Fire Safety Training with Adults Who Are Profoundly Mentally Retarded.
ERIC Educational Resources Information Center
Rae, Rosamond; Roll, David
1985-01-01
An intensive fire safety training program for profoundly mentally retarded institutionalized persons resulted in a significant decrease in mean evacuation time and gradual substitution of verbal for physical prompts. (CL)
2014-03-06
CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida prepare to participate in a training exercise at the Shuttle Landing Facility. A small fire is burning near a mock-up of a plane during the training exercise. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett
2014-03-06
CAPE CANAVERAL, Fla. - During a training exercise, Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida use hoses to put out a fire burning on a mock-up of a small plane at the Shuttle Landing Facility. They are wearing protective gear for the training exercise. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett
Hu, Xindi C; Andrews, David Q; Lindstrom, Andrew B; Bruton, Thomas A; Schaider, Laurel A; Grandjean, Philippe; Lohmann, Rainer; Carignan, Courtney C; Blum, Arlene; Balan, Simona A; Higgins, Christopher P; Sunderland, Elsie M
2016-10-11
Drinking water contamination with poly- and perfluoroalkyl substances (PFASs) poses risks to the developmental, immune, metabolic, and endocrine health of consumers. We present a spatial analysis of 2013-2015 national drinking water PFAS concentrations from the U.S. Environmental Protection Agency's (US EPA) third Unregulated Contaminant Monitoring Rule (UCMR3) program. The number of industrial sites that manufacture or use these compounds, the number of military fire training areas, and the number of wastewater treatment plants are all significant predictors of PFAS detection frequencies and concentrations in public water supplies. Among samples with detectable PFAS levels, each additional military site within a watershed's eight-digit hydrologic unit is associated with a 20% increase in PFHxS, a 10% increase in both PFHpA and PFOA, and a 35% increase in PFOS. The number of civilian airports with personnel trained in the use of aqueous film-forming foams is significantly associated with the detection of PFASs above the minimal reporting level. We find drinking water supplies for 6 million U.S. residents exceed US EPA's lifetime health advisory (70 ng/L) for PFOS and PFOA. Lower analytical reporting limits and additional sampling of smaller utilities serving <10000 individuals and private wells would greatly assist in further identifying PFAS contamination sources.
2016-01-01
Drinking water contamination with poly- and perfluoroalkyl substances (PFASs) poses risks to the developmental, immune, metabolic, and endocrine health of consumers. We present a spatial analysis of 2013–2015 national drinking water PFAS concentrations from the U.S. Environmental Protection Agency’s (US EPA) third Unregulated Contaminant Monitoring Rule (UCMR3) program. The number of industrial sites that manufacture or use these compounds, the number of military fire training areas, and the number of wastewater treatment plants are all significant predictors of PFAS detection frequencies and concentrations in public water supplies. Among samples with detectable PFAS levels, each additional military site within a watershed’s eight-digit hydrologic unit is associated with a 20% increase in PFHxS, a 10% increase in both PFHpA and PFOA, and a 35% increase in PFOS. The number of civilian airports with personnel trained in the use of aqueous film-forming foams is significantly associated with the detection of PFASs above the minimal reporting level. We find drinking water supplies for 6 million U.S. residents exceed US EPA’s lifetime health advisory (70 ng/L) for PFOS and PFOA. Lower analytical reporting limits and additional sampling of smaller utilities serving <10000 individuals and private wells would greatly assist in further identifying PFAS contamination sources. PMID:27752509
Fire Safety Training Handbook.
ERIC Educational Resources Information Center
Montgomery County Dept. of Fire and Rescue Services, Rockville, MD. Div. of Fire Prevention.
Designed for a community fire education effort, particularly in which local volunteers present general information on fire safety to their fellow citizens, this workbook contains nine lessons. Included are an overview of the household fire problem; instruction in basic chemistry and physics of fire, flammable liquids, portable fire extinguishers,…
1983-05-01
Firing data cards. PROCEDURES I. Prior to live fire exercises all firers must be oriented on range procedures. 2. Preparatory marksmanship training...Ordnance detail. 2. Range safety officer. 7. Medical personnel. 3. Firing line safety NCOs. 8. Control tower operators. i 4. Scorer (I per firer ). 9. Pit...phones and wire (for PIT commo). PROCEDURES I. Prior to live fire exercises, all firers must be oriented on range procedures. 2. Scorers are responsible
Detection of Bursts and Pauses in Spike Trains
Ko, D.; Wilson, C. J.; Lobb, C. J.; Paladini, C. A.
2012-01-01
Midbrain dopaminergic neurons in vivo exhibit a wide range of firing patterns. They normally fire constantly at a low rate, and speed up, firing a phasic burst when reward exceeds prediction, or pause when an expected reward does not occur. Therefore, the detection of bursts and pauses from spike train data is a critical problem when studying the role of phasic dopamine (DA) in reward related learning, and other DA dependent behaviors. However, few statistical methods have been developed that can identify bursts and pauses simultaneously. We propose a new statistical method, the Robust Gaussian Surprise (RGS) method, which performs an exhaustive search of bursts and pauses in spike trains simultaneously. We found that the RGS method is adaptable to various patterns of spike trains recorded in vivo, and is not influenced by baseline firing rate, making it applicable to all in vivo spike trains where baseline firing rates vary over time. We compare the performance of the RGS method to other methods of detecting bursts, such as the Poisson Surprise (PS), Rank Surprise (RS), and Template methods. Analysis of data using the RGS method reveals potential mechanisms underlying how bursts and pauses are controlled in DA neurons. PMID:22939922
Firefighters from Mayport Naval Station train at CCAFS
NASA Technical Reports Server (NTRS)
2000-01-01
During training exercises at Cape Canaveral Air Force Station Pad 30, firefighters with the Fire and Emergency Services at the Naval Station Mayport, Fla., turn their hoses toward the fire on the simulated aircraft.
1995-05-05
impoundment for a metal products manufacturer in Florida. During the site investigation, evidence of offsite contamination was found to be migrating onto...equipment, cross contamination through improper storage of samples) " Audit sampling documentation and procedures to ensure that samples are labeled...characterization of the occurrence and distribution of chemical contamination and site characteristics that are likely to influence human exposure or remediation
Claar, D.V.; Lilly, M.R.
1995-01-01
Ground-water and surface-water elevation data were collected at 52 sites from 1990 to 1994 by the U.S. Geological Survey in cooperation with the Alaska Department of Transportation and Public Facilities, Fairbanks International Airport. Water elevations were measured in 32 ground-water observation wells and at 20 surface-water sites to help characterize the geohydrology of the Fairbanks International Airport area. From 1990 to 1993, data were collected in the vicinity of the former fire-training area at the airport. From 1993 to 1994, the data-collection area was expanded to include the entire airport area.
The Development of a Single Tank Tactical Exercise for Training M1 Tank Commanders
1987-06-01
Evaluate the Conduct of Training NL NL NS Fire an M250 Grenade Launcher S S NS Identify Adjoining Map Sheets S S NS Identify Terrain Features on a Map S S...the Commander’s Weapon Station Establish, Enter, and Leave a Radio Net Estimate Range Evaluate the Conduct of Training Fire an M250 Grenade Launcher...from the Commander’s Weapon S Station (CWS) Fire an M250 Smoke Grenade Launcher Set Headspace and Timing on a Caliber .50 M2 HB Machinegun Zero a
ERIC Educational Resources Information Center
Lafayette School Corp., IN.
A two-pronged project model aimed to reduce the volume and increase the usefulness of health care materials and improve the literacy, verbal communication, and problem-solving skills of hospital employees. Regular meetings with hospital staff led project personnel to begin training with the cleaning staff in the areas of fire safety, back care,…
1990-07-01
Nitroaniline 4-Nitroaniline N-Nitroso-di-n-butylamine N-Nitrosopiperidine Pentachlorobenzene Pentachloronitrobenzene Phenacetin 2- Picoline Pronarnide 1,2,4,5... chromium . Cu: Chemical symbol for copper. 3 DARCY’S LAW: An equation describing the flow of fluids in porous media based on the assumption that the flow
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-01
... hot shutdown for fire areas in which both trains of safe-shutdown cables or equipment are located in... proposed action. The staff has concluded that such actions would not adversely affect the environment. The... case. This exemption request will not have a significant effect on the environment, as the largest...
Yanagawa, Youichi; Ishikawa, Kouhei; Takeuchi, Ikuto; Nagasawa, Hiroki; Jitsuiki, Kei; Ohsaka, Hiromichi; Omori, Kazuhiko
The local fire department executed a training simulation for chemical and explosive incidents at a large sports facility. In this training simulation, a physician-staffed helicopter arrived at the request of the fire department and landed just outside the cold zone in the parking area. The doctor and nurse of the helicopter were escorted to a red area in the cold zone, which was selected based on the results of postdecontamination triage. After the patients had been treated, they were air medically evacuated to the base hospital. In the Tokyo subway sarin attack in 1995, St Luke's International Hospital admitted over 600 victims. During this incident, 23.2% of medical staff suffered secondary injury from sarin exposure. If air medial crews respond with subsequent postexposure effects during flight, an affected pilot could lose control of the helicopter, resulting in a fatal crash. Based on potential safety concerns for air medical and ground personnel, our recommendation would be that air medical helicopters not be dispatched to sites of chemical, biological, radiological, nuclear, and explosive incidents. Copyright © 2018 Air Medical Journal Associates. Published by Elsevier Inc. All rights reserved.
Fire Weather Products for Public and Emergency Use: Extending Professional Resources to the Public
NASA Astrophysics Data System (ADS)
Rogers, M. A.; Schranz, S.; Kriederman, L.
2012-12-01
Large wildfires require significant resources to combat, including dedicated meteorological support to provide accurate and timely forecasts to assist incident commanders in making decisions for logistical and tactical firefighting operations. Smaller fires often require the same capabilities for understanding fire and the fire weather environment, but access to needed resources and tools is often limited due to technical, training, or education limitations. Providing fire weather information and training to incident commanders for smaller wildfires should prove to enhance firefighting capabilities and improve safety for both firefighters and for the public as well. One of the premier tools used to support fire weather forecasting for the largest wildfires is the FX-Net product, a thin-client version of the Advanced Weather Interactive Processing System used by NWS incident meteorologists (IMETs) deployed to large wildfires. We present results from an ongoing project to extend the sophisticated products available from FX-Net to more accessible and mobile software platforms, such as Google Earth. The project involves input from IMETs and fire commanders to identify the key parameters used in fighting wildfires, and involves a large training component for fire responders to utilize simplified products to improve understanding of fire weather in the context of firefighting operations.
Fire frequency, area burned, and severity: A quantitative approach to defining a normal fire year
Lutz, J.A.; Key, C.H.; Kolden, C.A.; Kane, J.T.; van Wagtendonk, J.W.
2011-01-01
Fire frequency, area burned, and fire severity are important attributes of a fire regime, but few studies have quantified the interrelationships among them in evaluating a fire year. Although area burned is often used to summarize a fire season, burned area may not be well correlated with either the number or ecological effect of fires. Using the Landsat data archive, we examined all 148 wildland fires (prescribed fires and wildfires) >40 ha from 1984 through 2009 for the portion of the Sierra Nevada centered on Yosemite National Park, California, USA. We calculated mean fire frequency and mean annual area burned from a combination of field- and satellite-derived data. We used the continuous probability distribution of the differenced Normalized Burn Ratio (dNBR) values to describe fire severity. For fires >40 ha, fire frequency, annual area burned, and cumulative severity were consistent in only 13 of 26 years (50 %), but all pair-wise comparisons among these fire regime attributes were significant. Borrowing from long-established practice in climate science, we defined "fire normals" to be the 26 year means of fire frequency, annual area burned, and the area under the cumulative probability distribution of dNBR. Fire severity normals were significantly lower when they were aggregated by year compared to aggregation by area. Cumulative severity distributions for each year were best modeled with Weibull functions (all 26 years, r2 ??? 0.99; P < 0.001). Explicit modeling of the cumulative severity distributions may allow more comprehensive modeling of climate-severity and area-severity relationships. Together, the three metrics of number of fires, size of fires, and severity of fires provide land managers with a more comprehensive summary of a given fire year than any single metric.
A Feasibility Study on the Establishment of a Fire Fighting Academy for the State of New Mexico.
ERIC Educational Resources Information Center
Sanchez, Alex A.
The report on the desirability and feasibility of establishing the New Mexico State Fire Academy and firemen training program is presented in three parts: (1) the result of a survey of firemen training, (2) a proposal for a total system of firemen training, and (3) an analysis of the cost of implementing this program of training and education. The…
2014-03-06
CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida review procedures after participating in a training exercise at the Shuttle Landing Facility. During the training simulation, firefighters used fire trucks and hoses to extinguish flames burning on and around a mock-up of a small plane. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett
STS-47 crew during fire fighting exercises at JSC's Fire Training Pit
NASA Technical Reports Server (NTRS)
1992-01-01
STS-47 Endeavour, Orbiter Vehicle (OV) 105, crewmembers line up along water hoses to extinguish a blaze in JSC's Fire Training Pit during fire fighting exercises. Manning the hose in the foreground are Payload Specialist Mamoru Mohri, holding the hose nozzle, backup Payload Specialist Takao Doi, Mission Specialist (MS) Jerome Apt, and Commander Robert L. Gibson, at rear. Lined up on the second hose are Pilot Curtis L. Brown, Jr, holding the hose nozzle, followed by MS N. Jan Davis, MS and Payload Commander (PLC) Mark C. Lee, and backup Payload Specialist Stan Koszelak. A veteran firefighter monitors the effort from a position between the two hoses. In the background, backup Payload Specialist Chiaki Naito-Mukai, donning gloves, and MS Mae C. Jemison look on. The Fire Training Pit is located across from the Gilruth Center Bldg 207. Mohri, Doi, and Mukai all represent Japan's National Space Development Agency (NASDA).
ERIC Educational Resources Information Center
Holburn, C. Steven; Dougher, Michael J.
1985-01-01
Techniques for training a severely retarded blind client to exit his living unit during a fire drill used a combination of negative and positive reinforcement. Following a shaping procedure, the client learned to leave his living unit from any internal point through generalization training and subsequent test probes. (Author/CL)
29 CFR 1910.156 - Fire brigades.
Code of Federal Regulations, 2010 CFR
2010-07-01
... training schools as the Maryland Fire and Rescue Institute; Iowa Fire Service Extension; West Virginia Fire... University, Lamar University, Reno Fire School, or the Delaware State Fire School.) (4) The employer shall... laboratory oven at a temperature of 500 °F (260 °C) for a period of five minutes. After cooling to ambient...
Warmack, Robert J. Bruce; Wolf, Dennis A.; Frank, Steven Shane
2016-09-06
Various apparatus and methods for smoke detection are disclosed. In one embodiment, a method of training a classifier for a smoke detector comprises inputting sensor data from a plurality of tests into a processor. The sensor data is processed to generate derived signal data corresponding to the test data for respective tests. The derived signal data is assigned into categories comprising at least one fire group and at least one non-fire group. Linear discriminant analysis (LDA) training is performed by the processor. The derived signal data and the assigned categories for the derived signal data are inputs to the LDA training. The output of the LDA training is stored in a computer readable medium, such as in a smoke detector that uses LDA to determine, based on the training, whether present conditions indicate the existence of a fire.
Warmack, Robert J. Bruce; Wolf, Dennis A.; Frank, Steven Shane
2015-10-27
Various apparatus and methods for smoke detection are disclosed. In one embodiment, a method of training a classifier for a smoke detector comprises inputting sensor data from a plurality of tests into a processor. The sensor data is processed to generate derived signal data corresponding to the test data for respective tests. The derived signal data is assigned into categories comprising at least one fire group and at least one non-fire group. Linear discriminant analysis (LDA) training is performed by the processor. The derived signal data and the assigned categories for the derived signal data are inputs to the LDA training. The output of the LDA training is stored in a computer readable medium, such as in a smoke detector that uses LDA to determine, based on the training, whether present conditions indicate the existence of a fire.
29 CFR 1926.155 - Definitions applicable to this subpart.
Code of Federal Regulations, 2014 CFR
2014-07-01
... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...
29 CFR 1926.155 - Definitions applicable to this subpart.
Code of Federal Regulations, 2012 CFR
2012-07-01
... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...
29 CFR 1926.155 - Definitions applicable to this subpart.
Code of Federal Regulations, 2011 CFR
2011-07-01
... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...
29 CFR 1926.155 - Definitions applicable to this subpart.
Code of Federal Regulations, 2013 CFR
2013-07-01
... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...
29 CFR 1926.155 - Definitions applicable to this subpart.
Code of Federal Regulations, 2010 CFR
2010-07-01
... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...
UNC Pembroke Laser Scanning Confocal Microscopy Facility
2016-04-29
cultures. INVASIVE FIRE ANTS Professor Lisa Kelly of UNC Pembroke has been trained on the new confocal system. Dr. Kelly’s research...interest in the trophic ecology of the invasive fire ant has begun to benefit from the wide field view and long working distances of a confocal imaging...of protein clearance pathways in living brain tissue cultures. INVASIVE FIRE ANTS Professor Lisa Kelly of UNC Pembroke has been trained on
How EPA's Asbestos Regulations Apply to Residential Buildings Used for Fire Training
Memos and guidance from the Office of Air Quality Planning and Standards that clarify how the Asbestos National Emissions Standard for Hazardous Air Pollutants applies to residential buildings used for fire training, also known as acquired structures.
2000-09-14
KENNEDY SPACE CENTER, FLA. -- A training officer controls elements of a fire training exercise at Cape Canaveral Air Force Station Pad 30 for firefighters with Fire and Emergency Services at the Naval Station Mayport, Fla. The firefighters tackled flames from a burning simulated aircraft.
2000-09-14
KENNEDY SPACE CENTER, FLA. -- A training officer controls elements of a fire training exercise at Cape Canaveral Air Force Station Pad 30 for firefighters with Fire and Emergency Services at the Naval Station Mayport, Fla. The firefighters tackled flames from a burning simulated aircraft.
Alvarado, Swanni T; Silva, Thiago Sanna Freire; Archibald, Sally
2018-07-15
Humans can alter fire dynamics in grassland systems by changing fire frequency, fire seasonality and fuel conditions. These changes have effects on vegetation structure and recovery, species composition, and ecosystem function. Understanding how human management can affect fire regimes is vital to detect potential changes in the resilience of plant communities, and to predict vegetation responses to human interventions. We evaluated the fire regimes of two recently protected areas in Madagascar (Ibity and Itremo NPA) and one in Brazil (Serra do Cipó NP) before and after livestock exclusion and fire suppression policies. We compare the pre- and post-management fire history in these areas and analyze differences in terms of total annual burned area, density of ignitions, burn scar size distribution, fire return period and seasonal fire distribution. More than 90% of total park areas were burned at least once during the studied period, for all parks. We observed a significant reduction in the number of ignitions for Ibity NPA and Serra do Cipó NP after livestock exclusion and active fire suppression, but no significant change in total burned area for each protected area. We also observed a seasonal shift in burning, with fires happening later in the fire season (October-November) after management intervention. However, the protected areas in Madagascar had shorter fire return intervals (3.23 and 1.82 years) than those in Brazil (7.91 years). Our results demonstrate that fire exclusion is unattainable, and probably unwarranted in tropical grassland conservation areas, but show how human intervention in fire and vegetation patterns can alter various aspects of the fire regimes. This information can help with formulating realistic and effective fire management policies in these valuable conservation areas. Copyright © 2018 Elsevier Ltd. All rights reserved.
Chen, Xuexia; Liu, Shuguang; Zhu, Zhiliang; Vogelmann, James E.; Li, Zhengpeng; Ohlen, Donald O.
2011-01-01
The concentrations of CO2 and other greenhouse gases in the atmosphere have been increasing and greatly affecting global climate and socio-economic systems. Actively growing forests are generally considered to be a major carbon sink, but forest wildfires lead to large releases of biomass carbon into the atmosphere. Aboveground forest biomass carbon (AFBC), an important ecological indicator, and fire-induced carbon emissions at regional scales are highly relevant to forest sustainable management and climate change. It is challenging to accurately estimate the spatial distribution of AFBC across large areas because of the spatial heterogeneity of forest cover types and canopy structure. In this study, Forest Inventory and Analysis (FIA) data, Landsat, and Landscape Fire and Resource Management Planning Tools Project (LANDFIRE) data were integrated in a regression tree model for estimating AFBC at a 30-m resolution in the Utah High Plateaus. AFBC were calculated from 225 FIA field plots and used as the dependent variable in the model. Of these plots, 10% were held out for model evaluation with stratified random sampling, and the other 90% were used as training data to develop the regression tree model. Independent variable layers included Landsat imagery and the derived spectral indicators, digital elevation model (DEM) data and derivatives, biophysical gradient data, existing vegetation cover type and vegetation structure. The cross-validation correlation coefficient (r value) was 0.81 for the training model. Independent validation using withheld plot data was similar with r value of 0.82. This validated regression tree model was applied to map AFBC in the Utah High Plateaus and then combined with burn severity information to estimate loss of AFBC in the Longston fire of Zion National Park in 2001. The final dataset represented 24 forest cover types for a 4 million ha forested area. We estimated a total of 353 Tg AFBC with an average of 87 MgC/ha in the Utah High Plateaus. We also estimated that 8054 Mg AFBC were released from 2.24 km2 burned forest area in the Longston fire. These results demonstrate that an AFBC spatial map and estimated biomass carbon consumption can readily be generated using existing database. The methodology provides a consistent, practical, and inexpensive way for estimating AFBC at 30-m resolution over large areas throughout the United States.
Teach Children Fire Will Burn.
ERIC Educational Resources Information Center
Children's Bureau (DHEW), Washington, DC.
This handbook, addressed to parents and others responsible for the safety of children, presents information on fire hazards, prevention and protection. Emphasizing an early start to fire safety training, it outlines the basic facts of fire safety education, listing the most frequent causes of fire and suggesting the organization of a Family Fire…
14 CFR 121.417 - Crewmember emergency training.
Code of Federal Regulations, 2014 CFR
2014-01-01
... fire extinguishers, with emphasis on type of extinguisher to be used on different classes of fires; and... handling of emergency situations including— (i) Rapid decompression; (ii) Fire in flight or on the surface... crewmember combats an actual or simulated fire using at least one type of installed hand fire extinguisher or...
14 CFR 121.417 - Crewmember emergency training.
Code of Federal Regulations, 2013 CFR
2013-01-01
... fire extinguishers, with emphasis on type of extinguisher to be used on different classes of fires; and... handling of emergency situations including— (i) Rapid decompression; (ii) Fire in flight or on the surface... crewmember combats an actual or simulated fire using at least one type of installed hand fire extinguisher or...
14 CFR 121.417 - Crewmember emergency training.
Code of Federal Regulations, 2012 CFR
2012-01-01
... fire extinguishers, with emphasis on type of extinguisher to be used on different classes of fires; and... handling of emergency situations including— (i) Rapid decompression; (ii) Fire in flight or on the surface... crewmember combats an actual or simulated fire using at least one type of installed hand fire extinguisher or...
Fire Safety. Managing School Facilities, Guide 6.
ERIC Educational Resources Information Center
Department for Education and Employment, London (England). Architects and Building Branch.
This booklet discusses how United Kingdom schools can manage fire safety and minimize the risk of fire. The guide examines what legislation school buildings must comply with and covers the major risks. It also describes training and evacuation procedures and provides guidance on fire precautions, alarm systems, fire fighting equipment, and escape…
Xie, Xiurui; Qu, Hong; Yi, Zhang; Kurths, Jurgen
2017-06-01
The spiking neural network (SNN) is the third generation of neural networks and performs remarkably well in cognitive tasks, such as pattern recognition. The temporal neural encode mechanism found in biological hippocampus enables SNN to possess more powerful computation capability than networks with other encoding schemes. However, this temporal encoding approach requires neurons to process information serially on time, which reduces learning efficiency significantly. To keep the powerful computation capability of the temporal encoding mechanism and to overcome its low efficiency in the training of SNNs, a new training algorithm, the accurate synaptic-efficiency adjustment method is proposed in this paper. Inspired by the selective attention mechanism of the primate visual system, our algorithm selects only the target spike time as attention areas, and ignores voltage states of the untarget ones, resulting in a significant reduction of training time. Besides, our algorithm employs a cost function based on the voltage difference between the potential of the output neuron and the firing threshold of the SNN, instead of the traditional precise firing time distance. A normalized spike-timing-dependent-plasticity learning window is applied to assigning this error to different synapses for instructing their training. Comprehensive simulations are conducted to investigate the learning properties of our algorithm, with input neurons emitting both single spike and multiple spikes. Simulation results indicate that our algorithm possesses higher learning performance than the existing other methods and achieves the state-of-the-art efficiency in the training of SNN.
Fire and worker health and safety: an introduction to the special issue.
Campbell, Richard; Levenstein, Charles
2015-02-01
One century ago, the landmark fire at the Triangle Shirtwaist Factory in New York City claimed the lives of 146 garment workers and helped spur the adoption of fire safety measures and laws targeting dangerous working conditions. Since that time, continuing advances have been made to address the threat of fire-in workplace fire safety practices and regulations, in training and safety requirements for firefighters and first responders, and in hazard communication laws that enhance disaster planning and response. Recent high profile events, including the West, Texas fertilizer plant explosion, derailments of fuel cargo trains, and garment factory fires in Bangladesh, have brought renewed attention to fire as a workplace health and safety issue and to the unevenness of safety standards and regulatory enforcement, in the United States as well as internationally. In this article, we provide an overview of fire as a workplace health and safety hazard and an introduction to the essays included in this special issue of New Solutions on fire and work. © 2015 SAGE Publications.
ERIC Educational Resources Information Center
Dixon, Dennis R.; Bergstrom, Ryan; Smith, Marlena N.; Tarbox, Jonathan
2010-01-01
Safety skills are an important but often neglected area of training for persons with developmental disabilities (DD). The present study reviewed the literature on teaching safety skills to persons with DD. Safety skills involve a variety of behaviors such as knowing how to cross the street or what to do in case of a house fire. A number of studies…
Bruce-Low, S S; Cotterrell, D; Jones, G E
2007-01-15
Fire fighter breathing apparatus instructors (BAIs) must possess the ability to respond to both the extrinsic stress of a high temperature environment and the intrinsic stress from wearing personal protective equipment (PPE) and self-contained breathing apparatus (SCBA), repeatedly and regularly, whilst training recruits in live fire training exercises (LFTEs). There are few previous investigations on BAIs in hot environments such as LFTEs, since the main research focus has been on regular fire fighters undertaking exercises in temperate or fire conditions at a moderate to high exercise intensity. In this study, the intrinsic cardiovascular stress effects of wearing PPE + SCBA were first investigated using a step test whilst wearing gym kit (control), weighted gym kit (a rucksack weighted to the equivalent of PPE + SCBA) and full PPE + SCBA (weight plus the effects of protective clothing). The extrinsic effects of the very hot environment were investigated in BIAs in LFTEs compared to mock fire training exercises (MFTEs), where the fire was not ignited. There was an increase in heart rate due to the modest workload imposed on the BAIs through carrying out the MFTEs (25.0 (18.7)%) compared to resting. However, when exposed to fire during the LFTEs, heat storage appears to be significant as the heart rate increased by up to 39.8 (+/-20.1)% over that of the mock LFTEs at temperate conditions. Thus, being able to dissipate heat from the PPE is particularly important in reducing the cardiovascular responses for BAIs during LFTEs.
Cohen-Hatton, Sabrina R; Honey, R C
2015-12-01
Decisions made by operational commanders at emergency incidents have been characterized as involving a period of information gathering followed by courses of action that are often generated without explicit plan formulation. We examined the efficacy of goal-oriented training in engendering explicit planning that would enable better communication at emergency incidents. While standard training mirrored current operational guidance, goal-oriented training incorporated "decision controls" that highlighted the importance of evaluating goals, anticipated consequences, and risk/benefit analyses once a potential course of action has been identified. In Experiment 1, 3 scenarios (a house fire, road traffic collision, and skip fire) were presented in a virtual environment, and in Experiment 2 they were recreated on the fireground. In Experiment 3, the house fire was recreated as a "live burn," and incident commanders and their crews responded to this scenario as an emergency incident. In all experiments, groups given standard training showed the reported tendency to move directly from information gathering to action, whereas those given goal-oriented training were more likely to develop explicit plans and show anticipatory situational awareness. These results indicate that training can be readily modified to promote explicit plan formulation that could facilitate plan sharing between incident commanders and their teams. (c) 2015 APA, all rights reserved).
Factors Controlling Vegetation Fires in Protected and Non-Protected Areas of Myanmar
Biswas, Sumalika; Vadrevu, Krishna Prasad; Lwin, Zin Mar; Lasko, Kristofer; Justice, Christopher O.
2015-01-01
Fire is an important disturbance agent in Myanmar impacting several ecosystems. In this study, we quantify the factors impacting vegetation fires in protected and non-protected areas of Myanmar. Satellite datasets in conjunction with biophysical and anthropogenic factors were used in a spatial framework to map the causative factors of fires. Specifically, we used the frequency ratio method to assess the contribution of each causative factor to overall fire susceptibility at a 1km scale. Results suggested the mean fire density in non-protected areas was two times higher than the protected areas. Fire-land cover partition analysis suggested dominant fire occurrences in the savannas (protected areas) and woody savannas (non-protected areas). The five major fire causative factors in protected areas in descending order include population density, land cover, tree cover percent, travel time from nearest city and temperature. In contrast, the causative factors in non-protected areas were population density, tree cover percent, travel time from nearest city, temperature and elevation. The fire susceptibility analysis showed distinct spatial patterns with central Myanmar as a hot spot of vegetation fires. Results from propensity score matching suggested that forests within protected areas have 11% less fires than non-protected areas. Overall, our results identify important causative factors of fire useful to address broad scale fire risk concerns at a landscape scale in Myanmar. PMID:25909632
Factors controlling vegetation fires in protected and non-protected areas of myanmar.
Biswas, Sumalika; Vadrevu, Krishna Prasad; Lwin, Zin Mar; Lasko, Kristofer; Justice, Christopher O
2015-01-01
Fire is an important disturbance agent in Myanmar impacting several ecosystems. In this study, we quantify the factors impacting vegetation fires in protected and non-protected areas of Myanmar. Satellite datasets in conjunction with biophysical and anthropogenic factors were used in a spatial framework to map the causative factors of fires. Specifically, we used the frequency ratio method to assess the contribution of each causative factor to overall fire susceptibility at a 1km scale. Results suggested the mean fire density in non-protected areas was two times higher than the protected areas. Fire-land cover partition analysis suggested dominant fire occurrences in the savannas (protected areas) and woody savannas (non-protected areas). The five major fire causative factors in protected areas in descending order include population density, land cover, tree cover percent, travel time from nearest city and temperature. In contrast, the causative factors in non-protected areas were population density, tree cover percent, travel time from nearest city, temperature and elevation. The fire susceptibility analysis showed distinct spatial patterns with central Myanmar as a hot spot of vegetation fires. Results from propensity score matching suggested that forests within protected areas have 11% less fires than non-protected areas. Overall, our results identify important causative factors of fire useful to address broad scale fire risk concerns at a landscape scale in Myanmar.
Development of a hazard-based method for evaluating the fire safety of passenger trains
DOT National Transportation Integrated Search
1999-01-01
The fire safety of U.S. passenger rail trains currently is addressed through small-scale flammability and smoke emission tests and performance criteria promulgated by the Federal Railroad Administration (FRA). The FRA approach relies heavily on test ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Palmer, E.
1997-04-01
This report documents the Resource Conservation and Recovery Act (RCRA) Facility Investigation/Remedial Investigation/Baseline Risk Assessment (RFI/RI/BRA) for the Fire Department Hose Training Facility (FDTF) (904-113G).
Information transmission using non-poisson regular firing.
Koyama, Shinsuke; Omi, Takahiro; Kass, Robert E; Shinomoto, Shigeru
2013-04-01
In many cortical areas, neural spike trains do not follow a Poisson process. In this study, we investigate a possible benefit of non-Poisson spiking for information transmission by studying the minimal rate fluctuation that can be detected by a Bayesian estimator. The idea is that an inhomogeneous Poisson process may make it difficult for downstream decoders to resolve subtle changes in rate fluctuation, but by using a more regular non-Poisson process, the nervous system can make rate fluctuations easier to detect. We evaluate the degree to which regular firing reduces the rate fluctuation detection threshold. We find that the threshold for detection is reduced in proportion to the coefficient of variation of interspike intervals.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warmack, Robert J. Bruce; Wolf, Dennis A.; Frank, Steven Shane
Various apparatus and methods for smoke detection are disclosed. In one embodiment, a method of training a classifier for a smoke detector comprises inputting sensor data from a plurality of tests into a processor. The sensor data is processed to generate derived signal data corresponding to the test data for respective tests. The derived signal data is assigned into categories comprising at least one fire group and at least one non-fire group. Linear discriminant analysis (LDA) training is performed by the processor. The derived signal data and the assigned categories for the derived signal data are inputs to the LDAmore » training. The output of the LDA training is stored in a computer readable medium, such as in a smoke detector that uses LDA to determine, based on the training, whether present conditions indicate the existence of a fire.« less
An organizational process for promoting home fire safety in two community settings.
Lehna, Carlee; Twyman, Stephanie; Fahey, Erin; Coty, Mary-Beth; Williams, Joe; Scrivener, Drane; Wishnia, Gracie; Myers, John
2017-02-01
The purpose of this study was to describe the home fire safety quality improvement model designed to aid organizations in achieving institutional program goals. The home fire safety model was developed from community-based participatory research (CBPR) applying training-the-trainer methods and is illustrated by an institutional case study. The model is applicable to other types of organizations to improve home fire safety in vulnerable populations. Utilizing the education model leaves trained employees with guided experience to build upon, adapt, and modify the home fire safety intervention to more effectively serve their clientele, promote safety, and meet organizational objectives. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
2014-03-06
CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters use a fire truck to put out a fire burning close to a mock-up of a small plane and a truck. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett
NASA Astrophysics Data System (ADS)
Smith, Mark A.; Turner, Monica G.; Rusch, Donald H.
2002-01-01
The US Department of Defense (DOD) manages over 10.1 million ha of land, much of which is used for training military personnel. However, vast sections receive little or no use, and military lands have become refuges for many species. At Fort McCoy, Wisconsin, USA, populations of the endangered Karner blue butterfly ( Lycaeides melissa samuelis) are found in oak and pine barren communities where wild lupine ( Lupinus perennis), a perennial forb required by Karner blue butterfly larvae, still occurs. Oak and pine barren communities are disturbance-dependent, and the barrens ecosystems in the Midwest have declined in extent by 98% because of fire suppression, succession, and habitat fragmentation. We studied the effects of disturbance by military manuever training on the density of lupine and Karner blue butterfly at Fort McCoy. We also wanted to determine whether military training activity could enhance Karner blue butterfly habitat. At locations where tracked vehicles had driven through lupine patches, the abundance of lupine and nectar-producing plants was greater in the median strip between vehicle ruts than in vehicle ruts or 5 m outside the vehicle ruts. The proportion of lupine stems with Karner blue butterfly larvae feeding sign (the ratio of stems fed upon to stems examined) was greater in areas where military vehicles had traveled than where they had not. The proportion of lupine stems with feeding sign and lupine stem density was also positively related to the occurrence of prior bivouacs and fires caused by military munitions. Shrub and forest canopy abundance were lower in areas traveled by tracked vehicles. At the scale of the lupine patch, lupine abundance and the proportion of lupine stems with feeding sign were positively correlated with military training activities, suggesting that maintenance of lupine habitat can be achieved in concert with military training.
Smith, Mark A; Turner, Monica G; Rusch, Donald H
2002-01-01
The US Department of Defense (DOD) manages over 10.1 million ha of land, much of which is used for training military personnel. However, vast sections receive little or no use, and military lands have become refuges for many species. At Fort McCoy, Wisconsin, USA, populations of the endangered Karner blue butterfly (Lycaeides melissa samuelis) are found in oak and pine barren communities where wild lupine (Lupinus perennis), a perennial forb required by Karner blue butterfly larvae, still occurs. Oak and pine barren communities are disturbance-dependent, and the barrens ecosystems in the Midwest have declined in extent by 98% because of fire suppression, succession, and habitat fragmentation. We studied the effects of disturbance by military manuever training on the density of lupine and Karner blue butterfly at Fort McCoy. We also wanted to determine whether military training activity could enhance Karner blue butterfly habitat. At locations where tracked vehicles had driven through lupine patches, the abundance of lupine and nectar-producing plants was greater in the median strip between vehicle ruts than in vehicle ruts or 5 m outside the vehicle ruts. The proportion of lupine stems with Karner blue butterfly larvae feeding sign (the ratio of stems fed upon to stems examined) was greater in areas where military vehicles had traveled than where they had not. The proportion of lupine stems with feeding sign and lupine stem density was also positively related to the occurrence of prior bivouacs and fires caused by military munitions. Shrub and forest canopy abundance were lower in areas traveled by tracked vehicles. At the scale of the lupine patch, lupine abundance and the proportion of lupine stems with feeding sign were positively correlated with military training activities, suggesting that maintenance of lupine habitat can be achieved in concert with military training.
Fire Streams. Fire Service Certification Series. Unit FSCS-FF-10-80.
ERIC Educational Resources Information Center
Pribyl, Paul F.
This training unit on fire streams is part of a 17-unit course package written to aid instructors in the development, teaching, and evaluation of fire fighters in the Wisconsin Fire Service Certification Series. The purpose stated for the 8-hour unit is to provide the fire fighters with an understanding of the characteristics, use, and application…
Fire Safety in Nursing Facilities: Participant's Coursebook.
ERIC Educational Resources Information Center
Walker (Bonnie) and Associates, Inc., Crofton, MD.
Fewer people die in nursing facility fires than in fires occurring in other places where older people live. Fire remains, however, a significant threat in nursing facilities. This book is centered around six "modules" that present a fire safety training program for managers and staff in nursing homes. These modules present the following…
Firefighter noise exposure during training activities and general equipment use.
Root, Kyle S; Schwennker, Catherine; Autenrieth, Daniel; Sandfort, Delvin R; Lipsey, Tiffany; Brazile, William J
2013-01-01
Multiple noise measurements were taken on 6 types of fire station equipment and 15 types of emergency response vehicle-related equipment used by firefighters during routine and emergency operations at 10 fire stations. Five of the six types of fire station equipment, when measured at a distance of one meter and ear level, emitted noise equal to or greater than 85 dBA, including lawn maintenance equipment, snow blowers, compressors, and emergency alarms. Thirteen of 15 types of equipment located on the fire engines emitted noise levels equal to or greater than 85 dBA, including fans, saws, alarms, and extrication equipment. In addition, noise measurements were taken during fire engine operations, including the idling vehicle, vehicle sirens, and water pumps. Results indicated that idling fire-engine noise levels were below 85 dBA; however, during water pump and siren use, noise levels exceeded 85 dBA, in some instances, at different locations around the trucks where firefighters would be stationed during emergency operations. To determine if the duration and use of fire fighting equipment was sufficient to result in overexposures to noise during routine training activities, 93 firefighter personal noise dosimetry samples were taken during 10 firefighter training activities. Two training activities per sampling day were monitored during each sampling event, for a mean exposure time of 70 min per day. The noise dosimetry samples were grouped based on job description to compare noise exposures between the different categories of job tasks commonly associated with fire fighting. The three job categories were interior, exterior, and engineering. Mean personal dosimetry results indicated that the average noise exposure was 78 dBA during the training activities that lasted 70 min on average. There was no significant difference in noise exposure between each of the three job categories. Although firefighters routinely use equipment and emergency response vehicles that can produce hazardous levels of noise, this study showed that the average noise levels experienced by firefighters was below generally accepted guidelines.
NASA Astrophysics Data System (ADS)
Randerson, J. T.; Chen, Y.; Giglio, L.; Rogers, B. M.; van der Werf, G.
2011-12-01
In several important biomes, including croplands and tropical forests, many small fires exist that have sizes that are well below the detection limit for the current generation of burned area products derived from moderate resolution spectroradiometers. These fires likely have important effects on greenhouse gas and aerosol emissions and regional air quality. Here we developed an approach for combining 1km thermal anomalies (active fires; MOD14A2) and 500m burned area observations (MCD64A1) to estimate the prevalence of these fires and their likely contribution to burned area and carbon emissions. We first estimated active fires within and outside of 500m burn scars in 0.5 degree grid cells during 2001-2010 for which MCD64A1 burned area observations were available. For these two sets of active fires we then examined mean fire radiative power (FRP) and changes in enhanced vegetation index (EVI) derived from 16-day intervals immediately before and after each active fire observation. To estimate the burned area associated with sub-500m fires, we first applied burned area to active fire ratios derived solely from within burned area perimeters to active fires outside of burn perimeters. In a second step, we further modified our sub-500m burned area estimates using EVI changes from active fires outside and within of burned areas (after subtracting EVI changes derived from control regions). We found that in northern and southern Africa savanna regions and in Central and South America dry forest regions, the number of active fires outside of MCD64A1 burned areas increased considerably towards the end of the fire season. EVI changes for active fires outside of burn perimeters were, on average, considerably smaller than EVI changes associated with active fires inside burn scars, providing evidence for burn scars that were substantially smaller than the 25 ha area of a single 500m pixel. FRP estimates also were lower for active fires outside of burn perimeters. In our analysis we quantified how including sub-500m burned area influenced global burned area, carbon emissions, and net ecosystem exchange (NEE) in different continental regions using the Global Fire Emissions Database (GFED) biogeochemical model. We conclude by discussing validation needs using higher resolution visible and thermal imagery.
2014-03-01
purpose of the study was to determine if the use of a simulator is at least as effective in marksmanship training as traditional dry fire techniques...determine if the use of a simulator is at least as effective in marksmanship training as traditional dry fire techniques. A between-groups study with a...marksmanship. Naval commands could use the information to effectively maintain gun qualifications for inport duty section watch bills and constant anti
Suggested Guide for Fire Service Standard Operating Procedures.
ERIC Educational Resources Information Center
Gillett, Merl; Hertzler, Simon L.
Suggested guidelines for the development of fire service standard operating procedures are presented in this document. Section topics are as follow: chain of command; communications; emergency response; apparatus; fire service training; disaster response; aircraft fire safety; mutual aid; national reporting system (example reporting forms);…
State of Alaska Fire Service Training. Instructor Certification Standards.
ERIC Educational Resources Information Center
Hagevig, William
Designed for local Alaskan fire departments, this pamphlet provides the criteria and qualifications for certificates of firefighter instructors (basic, advanced, master), a list of approved subject categories for each level of certification, sample certification applications, a list of resource publications, and a training course outline (basic…
Managing multiple-casualty incidents: a rural medical preparedness training assessment.
Glow, Steven D; Colucci, Vincent J; Allington, Douglas R; Noonan, Curtis W; Hall, Earl C
2013-08-01
The objectives of this study were to develop a novel training model for using mass-casualty incident (MCI) scenarios that trained hospital and prehospital staff together using Microsoft Visio, images from Google Earth and icons representing first responders, equipment resources, local hospital emergency department bed capacity, and trauma victims. The authors also tested participants' knowledge in the areas of communications, incident command systems (ICS), and triage. Participants attended Managing Multiple-Casualty Incidents (MCIs), a one-day training which offered pre- and post-tests, two one-hour functional exercises, and four distinct, one-hour didactic instructional periods. Two MCI functional exercises were conducted. The one-hour trainings focused on communications, National Incident Management Systems/Incident Command Systems (NIMS/ICS) and professional roles and responsibilities in NIMS and triage. The trainings were offered throughout communities in western Montana. First response resource inventories and general manpower statistics for fire, police, Emergency Medical Services (EMS), and emergency department hospital bed capacity were determined prior to MCI scenario construction. A test was given prior to and after the training activities. A total of 175 firefighters, EMS, law enforcement, hospital personnel or other first-responders completed the pre- and post-test. Firefighters produced higher baseline scores than all other disciplines during pre-test analysis. At the end of the training all disciplines demonstrated significantly higher scores on the post-test when compared with their respective baseline averages. Improvements in post-test scores were noted for participants from all disciplines and in all didactic areas: communications, NIMS/ICS, and triage. Mass-casualty incidents offer significant challenges for prehospital and emergency room workers. Fire, Police and EMS personnel must secure the scene, establish communications, define individuals' roles and responsibilities, allocate resources, triage patients, and assign transport priorities. After emergency department notification and in advance of arrival, emergency department personnel must assess available physical resources and availability and type of manpower, all while managing patients already under their care. Mass-casualty incident trainings should strengthen the key, individual elements essential to well-coordinated response such as communications, incident management system and triage. The practice scenarios should be matched to the specific resources of the community. The authors also believe that these trainings should be provided with all disciplines represented to eliminate training "silos," to allow for discussion of overlapping jurisdictional or organizational responsibilities, and to facilitate team building.
NASA Technical Reports Server (NTRS)
Brass, J. A.; Riggan, P. J.; Ambrosia, V. G.; Lockwood, R. N.; Pereira, J. A.; Higgins, R. G.; Peterson, David L. (Technical Monitor)
1995-01-01
Remotely sensed estimations of regional and global emissions from biomass combustion have been used to characterize fire behavior, determine fire intensity, and estimate burn area. Highly temporal, low resolution satellite data have been used to calculate estimates of fire numbers and area burned. These estimates of fire activity and burned area have differed dramatically, resulting in a wide range of predictions on the ecological and environmental impacts of fires. As part of the Brazil/United States Fire Initiative, an aircraft campaign was initiated in 1992 and continued in 1994. This multi-aircraft campaign was designed to assist in the characterization of fire activity, document fire intensity and determine area burned over prescribed, agricultural and wildland fires in the savanna and forests of central Brazil. Using a unique, multispectral scanner (AIRDAS), designed specifically for fire characterization, a variety of fires and burned areas were flown with a high spatial and high thermal resolution scanner. The system was used to measure flame front size, rate of spread, ratio of smoldering to flaming fronts and fire intensity. In addition, long transects were flown to determine the size of burned areas within the cerrado and transitional ecosystems. The authors anticipate that the fire activity and burned area estimates reported here will lead to enhanced information for precise regional trace gas prediction.
ERIC Educational Resources Information Center
International Association of Fire Chiefs, New York, NY.
A manual intended to help fire departments and Civil Defense organizations train people to support regular fire forces during a national emergency is presented. It contains 11 chapters: Introduction, Modern Weapons and Radioactive Fallout, Role of Fire Service in Civil Defense, Local Fire Department Organization, Role of Support Assistants in…
Inspection. Fire Service Certification Series. Unit FSCS-FF-17-81.
ERIC Educational Resources Information Center
Pribyl, Paul F.
This training unit on inspection is part of a 17-unit course package written to aid instructors in the development, teaching, and evaluation of fire fighters in the Wisconsin Fire Service Certification Series. The purpose stated for the 4.5-hour unit is to give the fire fighters an insight into their responsibilities concerning fire prevention and…
Resilience and high performance: What the wildland fire community can learn from the U.S. Military
James Saveland
2011-01-01
Recent advances in the science of psychology are rapidly mending the Cartesian mind-body rift. The U.S. Military has recognized the importance of mental fitness to compliment physical fitness. Health-of- the-Force was a strategic priority of the Chairman of the Joint Chiefs of Staff in 2009-2010. Wellness enhancement and training is one of the four focus areas of a...
The decommissioned Wurtsmith Air Force Base former Fire Training Cell (FT-02) facility has been the focus of several geophysical investigations. After several decades of fire training exercises, significant amounts of hydrocarbons and some solvents seeped into the subsurface cont...
The decommissioned Wurtsmith Air Force Base former Fire Training Cell (FT-02) facility has been the focus of several geophysical investigations. After several decades of fire training exercises, significant amounts of hydrocarbons and some solvents seeped into the Subsurface cont...
Fire management assessment of Eastern Province, Zambia
L. T. Hollingsworth; D. Johnson; G. Sikaundi; S. Siame
2015-01-01
The mission that produced this assessment was prompted by requests from Forestry Department personnel in Zambia to the United States Agency for International Development (USAID) for formal fire management training. USAID contacted the United States Forest Service's (USFS) International Programs (IP) with the training request. Together, USFS, USAID, and Zambian...
Firefighters from Mayport Naval Station train at CCAFS
NASA Technical Reports Server (NTRS)
2000-01-01
Firefighters surround a burning simulated aircraft during training exercises Cape Canaveral Air Force Station Pad 30. Those at left wait their turn as the crew on the right turn their hoses toward the fire. The firefighters are with Fire and Emergency Services at the Naval Station Mayport, Fla.
Evidence of fuels management and fire weather influencing fire severity in an extreme fire event
Lydersen, Jamie M; Collins, Brandon M.; Brooks, Matthew L.; Matchett, John R.; Shive, Kristen L.; Povak, Nicholas A.; Kane, Van R.; Smith, Douglas F.
2017-01-01
Following changes in vegetation structure and pattern, along with a changing climate, large wildfire incidence has increased in forests throughout the western U.S. Given this increase there is great interest in whether fuels treatments and previous wildfire can alter fire severity patterns in large wildfires. We assessed the relative influence of previous fuels treatments (including wildfire), fire weather, vegetation and water balance on fire severity in the Rim Fire of 2013. We did this at three different spatial scales to investigate whether the influences on fire severity changed across scales. Both fuels treatments and previous low to moderate severity wildfire reduced the prevalence of high severity fire. In general, areas without recent fuels treatments and areas that previously burned at high severity tended to have a greater proportion of high severity fire in the Rim Fire. Areas treated with prescribed fire, especially when combined with thinning, had the lowest proportions of high severity. Proportion of the landscape burned at high severity was most strongly influenced by fire weather and proportional area previously treated for fuels or burned by low to moderate severity wildfire. The proportion treated needed to effectively reduce the amount of high fire severity fire varied by spatial scale of analysis, with smaller spatial scales requiring a greater proportion treated to see an effect on fire severity. When moderate and high severity fire encountered a previously treated area, fire severity was significantly reduced in the treated area relative to the adjacent untreated area. Our results show that fuels treatments and low to moderate severity wildfire can reduce fire severity in a subsequent wildfire, even when burning under fire growth conditions. These results serve as further evidence that both fuels treatments and lower severity wildfire can increase forest resilience.
Brandon M. Collins; Richard G. Everett; Scott L. Stephens
2011-01-01
We re-sampled areas included in an unbiased 1911 timber inventory conducted by the U.S. Forest Service over a 4000 ha study area. Over half of the re-sampled area burned in relatively recent management- and lightning-ignited fires. This allowed for comparisons of both areas that have experienced recent fire and areas with no recent fire, to the same areas historically...
Trial by Fire (and Tornado) Taught Us to Plan for Crises.
ERIC Educational Resources Information Center
Caylor, Mary Jane
1991-01-01
Based on Huntsville (Alabama) schools' experience with a devastating fire, the superintendent later ensured adequate fire insurance coverage, promoted regular fire drills, and developed an emergency response plan that delineated staff responsibilities, communication modes, and training and updating procedures. The plan served the district well…
14 CFR 121.417 - Crewmember emergency training.
Code of Federal Regulations, 2011 CFR
2011-01-01
... crewmember combats an actual or simulated fire using at least one type of installed hand fire extinguisher or... by paragraph (d) of this section for combatting fires aboard airplanes; (ii) At least one approved firefighting drill in which the crewmember combats an actual fire using at least one type of installed hand...
Fire Prevention Inspection Procedures.
ERIC Educational Resources Information Center
Pribyl, Paul F.
Lesson plans are provided for a fire prevention inspection course of the Wisconsin Fire Service Training program. Objectives for the course are to enable students to describe and conduct fire prevention inspections, to identify and correct hazards common to most occupancies, to understand the types of building construction and occupancy, and to…
Keeping Haines Real - Or Really Changing Haines?
Brian E. Potter; Dan Borsum; Don Haines
2002-01-01
Most incident command teams can handle low- to moderate-intensity fires with few unanticipated problems. However, high-intensity situations, especially the plume-dominated fires that often develop when winds are low and erratic behavior is unexpected, can create dangerous situations even for well-trained, experienced fire crews (Rothermel 1991). Plume-dominated fires...
LVQ and backpropagation neural networks applied to NASA SSME data
NASA Technical Reports Server (NTRS)
Doniere, Timothy F.; Dhawan, Atam P.
1993-01-01
Feedfoward neural networks with backpropagation learning have been used as function approximators for modeling the space shuttle main engine (SSME) sensor signals. The modeling of these sensor signals is aimed at the development of a sensor fault detection system that can be used during ground test firings. The generalization capability of a neural network based function approximator depends on the training vectors which in this application may be derived from a number of SSME ground test-firings. This yields a large number of training vectors. Large training sets can cause the time required to train the network to be very large. Also, the network may not be able to generalize for large training sets. To reduce the size of the training sets, the SSME test-firing data is reduced using the learning vector quantization (LVQ) based technique. Different compression ratios were used to obtain compressed data in training the neural network model. The performance of the neural model trained using reduced sets of training patterns is presented and compared with the performance of the model trained using complete data. The LVQ can also be used as a function approximator. The performance of the LVQ as a function approximator using reduced training sets is presented and compared with the performance of the backpropagation network.
Migala, Alexandre F; Brown, Susann E
2012-12-01
In September 2011, wildfires in Bastrop County, TX, were the most destructive in the state's history, consuming more than 34000 acres (13759 hectares) and more than 1600 homes in the process. The wildfires began by consuming more than 30 homes across 2 miles (3.2 km) in 17 minutes, raising the fear that local residents may not have had sufficient time to escape the conflagration. Texas Task Force 1 deployed for a new mission, the search and recovery of human remains. Although there have been other larger and more widespread fires in the past, it was the speed at which this fire spread that created the environment requiring such a search. The mission was focused primarily on human detection, searching an area almost 72 square miles (186 km(2)) between September 7 and 11, 2011. To our knowledge, never before have human remains detection dogs been tasked with such an undertaking. Lessons learned from this event will educate all levels of government agencies, emergency medical services, fire departments, law enforcement, utilities, veterinary services, and search and rescue/recovery activities in the future. The utilization of human remains detection canines integrated with search teams trained in larger scale events is one such area that will benefit from this experience, with a final area searched of 15 598 acres (6312 hectares). Copyright © 2012 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.
Global Burned Area and Biomass Burning Emissions from Small Fires
NASA Technical Reports Server (NTRS)
Randerson, J. T.; Chen, Y.; vanderWerf, G. R.; Rogers, B. M.; Morton, D. C.
2012-01-01
In several biomes, including croplands, wooded savannas, and tropical forests, many small fires occur each year that are well below the detection limit of the current generation of global burned area products derived from moderate resolution surface reflectance imagery. Although these fires often generate thermal anomalies that can be detected by satellites, their contributions to burned area and carbon fluxes have not been systematically quantified across different regions and continents. Here we developed a preliminary method for combining 1-km thermal anomalies (active fires) and 500 m burned area observations from the Moderate Resolution Imaging Spectroradiometer (MODIS) to estimate the influence of these fires. In our approach, we calculated the number of active fires inside and outside of 500 m burn scars derived from reflectance data. We estimated small fire burned area by computing the difference normalized burn ratio (dNBR) for these two sets of active fires and then combining these observations with other information. In a final step, we used the Global Fire Emissions Database version 3 (GFED3) biogeochemical model to estimate the impact of these fires on biomass burning emissions. We found that the spatial distribution of active fires and 500 m burned areas were in close agreement in ecosystems that experience large fires, including savannas across southern Africa and Australia and boreal forests in North America and Eurasia. In other areas, however, we observed many active fires outside of burned area perimeters. Fire radiative power was lower for this class of active fires. Small fires substantially increased burned area in several continental-scale regions, including Equatorial Asia (157%), Central America (143%), and Southeast Asia (90%) during 2001-2010. Globally, accounting for small fires increased total burned area by approximately by 35%, from 345 Mha/yr to 464 Mha/yr. A formal quantification of uncertainties was not possible, but sensitivity analyses of key model parameters caused estimates of global burned area increases from small fires to vary between 24% and 54%. Biomass burning carbon emissions increased by 35% at a global scale when small fires were included in GFED3, from 1.9 Pg C/yr to 2.5 Pg C/yr. The contribution of tropical forest fires to year-to-year variability in carbon fluxes increased because small fires amplified emissions from Central America, South America and Southeast Asia-regions where drought stress and burned area varied considerably from year to year in response to El Nino-Southern Oscillation and other climate modes.
Impact of postfire management on soil respiration and C concentration in a managed hemiboreal forest
NASA Astrophysics Data System (ADS)
Köster, Kajar; Seglinš, Katrin; Parro, Kristi; Metslaid, Marek
2017-04-01
Fire is the main natural disturbance in boreal forests and it is expected that its frequency will increase as a result of climate change. Fire is the primary process which organizes the physical and biological attributes of the boreal biome and influences energy flows and biogeochemical cycles, particularly the carbon (C) cycle. The objective of this study was to assess the impact of forest fire and time since forest fire on soil respiration and soil C concentrations in scenarios where the area was managed or was not managed after fire disturbance. This study was carried out in two permanent research areas in northwestern Estonia (hemiboreal forest zone) that were damaged by fire: Vihterpalu (59o13' N 23o49' E) and Nõva (59o10' N 23o45' E). Fire occurred in Vihterpalu in year 1992 (550 ha burned), when the forest was 52 years old, and in Nõva in year 2008 (800 ha burned), when the forest was 70 years old. Before the fire disturbance both sites were covered with planted or sown Scots pine (Pinus sylvestris L.) forests originally regenerated after heavy fires in 1940 (Nõva) and 1951 (Vihterpalu). In all areas we are dealing with stand replacing fires where all (or almost all) of the stand was destroyed by fire. In both study areas three different types of sample areas were set up: 1) control areas (CO), that are unburned and no management activities carried out; 2) burned and cleared (BC) with salvage logging, areas in which all dead and live trees were harvested from the plot after fire; 3) burned and uncleared areas (BU), areas without management in which both dead and live trees were left on the plots after fire disturbance. On every area three measuring transects (40 m long) were established where soil respiration (g CO2 m-2h-1) was measured on five collars, and five soil samples (0.5 m long and 0.05 m in diameter) were taken to estimate soil C (kg m-2) content. In our study, highest soil respiration values were recorded in control (CO) areas, which are not affected by forest fires. In the fire areas (BC and BU) the average soil respiration values were more than two times lower than in the areas which were not affected by forest fires. Different post-fire management activities (removing or leaving damaged trees) did not affect the soil respiration values. Soil temperature had a significant impact on the CO2 flows. The recorded average soil temperature was lowest in CO and highest in BU areas, respectively. In spring and autumn soil temperatures in disturbed areas, as well as in cleared areas, were rising faster than in CO areas. In our study, 1992 fire areas had thicker litter and organic layer compared to 2008 fire areas. Most of the litter and organic matter was found in CO areas, followed by BU and BC areas. The highest C concentrations were found in CO areas. In the fire areas C concentration was also affected by the post-disturbance management, as in BC areas soil C concentration was lower compared to BU areas.
Gębka, Karolina; Bełdowski, Jacek; Bełdowska, Magdalena
2016-11-01
Military activities have been conducted on land and at sea. Both during conflicts and in peace time, some regions served as a military training ground which included firing positions and bunkers. Mercury fulminate has been used in ammunition primers and detonators. Certain amount of ammunition was dumped into the Baltic Sea after the Second World War. Because of corroded containers, mercury can be released into the marine environment. The soil and sediment samples were taken from military training grounds, southern Baltic in 2014 and 2015. The concentration of mercury was determined by AMA-254 analyzer. Hg concentration was higher in the places of military activities, as compared to other areas. Ten times increased concentration of Hg was determined in soil sample collected in area of active gun range compared to the reference station. The significant higher concentration of mercury was detected in stations where chemical warfare agents were found.
Firefighters from Mayport Naval Station train at CCAFS
NASA Technical Reports Server (NTRS)
2000-01-01
A firefighter (right) holds a water hose in readiness as others enter a smoke-filled simulated aircraft. The activities are part of fire training exercises at Cape Canaveral Air Force Station Pad 30 for firefighters with Fire and Emergency Services at the Naval Station Mayport, Fla. The firefighters have already extinguished flames from the aircraft.
Johnson, Lane B; Kipfmueller, Kurt F
2016-06-01
We reconstructed fire occurrence near a fur-trade era canoe travel corridor (used ca. 1780-1802) in the Quetico-Superior region west of Lake Superior to explore the possibility of human influence on pre-fire suppression rates of fire occurrence. Our research objectives were to (1) examine the spatial and temporal patterns of fire in the study area, (2) test fires' strength of association with regional drought, and (3) assess whether reconstructed fire frequencies could be explained by observed rates of lightning fire ignition over the modern period of record. We developed a 420-year fire history for the eastern portion of Lac La Croix in the Boundary Waters Canoe Area Wilderness (BWCAW). Seventy-one fire-scarred samples were collected from remnant Pinus resinosa Ait. (red pine) stumps and logs from thirteen distinct island and three mainland forest stands. Collectively these samples contained records of 255 individual fire scars representing 79 fire events from 1636 to 1933 (study area mean fire intervals [MFI] 3.8 yr). Reconstructed fires were spatially and temporally asynchronous and not strongly associated with regional drought (P > 0.05). When compared to the conservative, tree-ring reconstructed estimate of historical fire occurrence and modern lightning-caused fires (1929-2012), a noticeable change in the distribution and frequency of fires within the study area was evident with only two lightning-ignited island fires since 1934 in the study area. Our results suggest a high likelihood that indigenous land use contributed to surface fire ignitions within our study area and highlights the importance of examining the potential effects of past indigenous land use when determining modern approaches to fire and wilderness management in fire-adapted ecosystems.
Miettinen, Jukka; Shi, Chenghua; Liew, Soo Chin
2017-10-01
In this paper, we analyze the spatio-temporal distribution of vegetation fires in Peninsular Malaysia, Sumatra, and Borneo in the severe El Niño year of 2015, concentrating on the distribution of fires between mineral soils and peatland areas, and between land cover types in peatland areas. The results reveal that 53% of all Moderate Resolution Imaging Spectroradiometer (MODIS) fire detections were recorded in peatlands that cover only 12% of the study area. However, fire occurrence in the peatland areas was highly dependent on land cover type. Pristine peat swamp forests (PSF) experienced only marginal fire activity (30 fire detections per 1000 km 2 ) compared to deforested undeveloped peatlands (831-915 fire detections per 1000 km 2 ). Our results also highlight the extreme fire vulnerability of the southern Sumatran and Bornean peatlands under strong El Niño conditions: 71% of all peatland hotspots were detected in the provinces of South Sumatra and Central Kalimantan, which contain 29% of peatlands in the study area. Degraded PSF and all deforested peatland land cover types, including managed areas, in the two provinces were severely affected, demonstrating how difficult it is to protect even managed drained agricultural areas from unwanted fires during dry periods. Our results thereby advocate rewetting and rehabilitation as the primary management option for highly fire prone degraded undeveloped peatland areas, whenever feasible, as a means to reduce fire risk during future dry episodes.
NASA Astrophysics Data System (ADS)
Miettinen, Jukka; Shi, Chenghua; Liew, Soo Chin
2017-10-01
In this paper, we analyze the spatio-temporal distribution of vegetation fires in Peninsular Malaysia, Sumatra, and Borneo in the severe El Niño year of 2015, concentrating on the distribution of fires between mineral soils and peatland areas, and between land cover types in peatland areas. The results reveal that 53% of all Moderate Resolution Imaging Spectroradiometer (MODIS) fire detections were recorded in peatlands that cover only 12% of the study area. However, fire occurrence in the peatland areas was highly dependent on land cover type. Pristine peat swamp forests (PSF) experienced only marginal fire activity (30 fire detections per 1000 km2) compared to deforested undeveloped peatlands (831-915 fire detections per 1000 km2). Our results also highlight the extreme fire vulnerability of the southern Sumatran and Bornean peatlands under strong El Niño conditions: 71% of all peatland hotspots were detected in the provinces of South Sumatra and Central Kalimantan, which contain 29% of peatlands in the study area. Degraded PSF and all deforested peatland land cover types, including managed areas, in the two provinces were severely affected, demonstrating how difficult it is to protect even managed drained agricultural areas from unwanted fires during dry periods. Our results thereby advocate rewetting and rehabilitation as the primary management option for highly fire prone degraded undeveloped peatland areas, whenever feasible, as a means to reduce fire risk during future dry episodes.
Physical fitness of an industrial fire department vs. a municipal fire department.
Garver, Julie N; Jankovitz, Kristine Z; Danks, Jane M; Fittz, Ashley A; Smith, Heather S; Davis, Steven C
2005-05-01
Both industrial and municipal firefighters need to maintain high levels of physical fitness and minimize cardiovascular risk factors. The nature of firefighter responsibilities in industrial and municipal settings may vary, affecting the ability to sustain high levels of physical fitness. We compared the working conditions, physical fitness, and exercise training practices of an industrial fire department (n = 17) to those of a nearby municipal fire department (n = 55). After informed consent, aerobic capacity, muscular strength, muscular endurance, body composition, flexibility, blood lipid concentrations, and blood pressure levels were measured. Exercise training practices and related factors were assessed using a questionnaire. Despite programmatic differences, these departments demonstrated similar, relatively high degrees of physical fitness and similar blood lipid concentrations, blood pressure levels, and cardiac risk factors. It is recommended that fire departments involve appropriately trained staff, schedule on-duty times for exercise, offer well-equipped exercise facilities, and follow National Strength and Conditioning Association (NSCA) and American College of Sports Medicine (ACSM) guidelines for exercise conditioning in order to maintain a high degree of physical fitness.
Fire regime in Mediterranean ecosystem
NASA Astrophysics Data System (ADS)
Biondi, Guido; Casula, Paolo; D'Andrea, Mirko; Fiorucci, Paolo
2010-05-01
The analysis of burnt areas time series in Mediterranean regions suggests that ecosystems characterising this area consist primarily of species highly vulnerable to the fire but highly resilient, as characterized by a significant regenerative capacity after the fire spreading. In a few years the area burnt may once again be covered by the same vegetation present before the fire. Similarly, Mediterranean conifer forests, which often refers to plantations made in order to reforest the areas most severely degraded with high erosion risk, regenerate from seed after the fire resulting in high resilience to the fire as well. Only rarely, and usually with negligible damages, fire affects the areas covered by climax species in relation with altitude and soil types (i.e, quercus, fagus, abies). On the basis of these results, this paper shows how the simple Drossel-Schwabl forest fire model is able to reproduce the forest fire regime in terms of number of fires and burned area, describing whit good accuracy the actual fire perimeters. The original Drossel-Schwabl model has been slightly modified in this work by introducing two parameters (probability of propagation and regrowth) specific for each different class of vegetation cover. Using model selection methods based on AIC, the model with the optimal number of classes with different fire behaviour was selected. Two different case studies are presented in this work: Regione Liguria and Regione Sardegna (Italy). Both regions are situated in the center of the Mediterranean and are characterized by a high number of fires and burned area. However, the two regions have very different fire regimes. Sardinia is affected by the fire phenomenon only in summer whilst Liguria is affected by fires also in winter, with higher number of fires and larger burned area. In addition, the two region are very different in vegetation cover. The presence of Mediterranean conifers, (Pinus Pinaster, Pinus Nigra, Pinus halepensis) is quite spread in Liguria and is limited in Sardinia. What is common in the two regions is the widespread presence of shrub species frequently spread by fire. The analysis in the two regions thus allows in a rather limited area to study almost all the species that characterize the Mediterranean region. This work shows that the fire regime in Mediterranean area is strongly related with vegetation patterns, is almost totally independent by the cause of ignition, and only partially dependent by fire extinguishing actions.
Fire Protection for Rural Communities.
ERIC Educational Resources Information Center
Hagevig, William A.
Fire protection in rural Alaskan communities depends on individual home fire prevention and protection rather than on the services offered by a centralized fire department. Even when help is summoned to extinguish a blaze, aid does not come in the form of a cadre of highly trained firefighters; it comes instead from whomever happens to be in the…
Near real-time estimation of burned area using VIIRS 375 m active fire product
NASA Astrophysics Data System (ADS)
Oliva, P.; Schroeder, W.
2016-12-01
Every year, more than 300 million hectares of land burn globally, causing significant ecological and economic consequences, and associated climatological effects as a result of fire emissions. In recent decades, burned area estimates generated from satellite data have provided systematic global information for ecological analysis of fire impacts, climate and carbon cycle models, and fire regimes studies, among many others. However, there is still need of near real-time burned area estimations in order to assess the impacts of fire and estimate smoke and emissions. The enhanced characteristics of the Visible Infrared Imaging Radiometer Suite (VIIRS) 375 m channels on board the Suomi National Polar-orbiting Partnesship (S-NPP) make possible the use of near real-time active fire detection data for burned area estimation. In this study, consecutive VIIRS 375 m active fire detections were aggregated to produce the VIIRS 375 m burned area (BA) estimation over ten ecologically diverse study areas. The accuracy of the BA estimations was assessed by comparison with Landsat-8 supervised burned area classification. The performance of the VIIRS 375 m BA estimates was dependent on the ecosystem characteristics and fire behavior. Higher accuracy was observed in forested areas characterized by large long-duration fires, while grasslands, savannas and agricultural areas showed the highest omission and commission errors. Complementing those analyses, we performed the burned area estimation of the largest fires in Oregon and Washington states during 2015 and the Fort McMurray fire in Canada 2016. The results showed good agreement with NIROPs airborne fire perimeters proving that the VIIRS 375 m BA estimations can be used for near real-time assessments of fire effects.
NASA A-Train and Terra Observations of the 2010 Russian Wildfires
NASA Technical Reports Server (NTRS)
Witte, J. C.; Douglass, A. R.; DaSilva, A.; Torres, O.; Levy, R.; Duncan, B. N.
2011-01-01
Wildfires raged throughout western Russia and parts of Eastern Europe during a persistent heat wave in the summer of 2010. Anomalously high surface temperatures (35 - 41 C) and low relative humidity (9 - 25 %) from mid- June to mid-August 2010 shown by analysis of radiosonde data from multiple sites in western Russia were ideal conditions for the wildfires to thrive. Measurements of outgoing longwave radiation (OLR) from the Atmospheric Infrared Sounder (AIRS) over western Russian indicate persistent subsidence during the heat wave. Daily three-day back-trajectories initiated over Moscow reveal a persistent anticyclonic circulation for 18 days in August, coincident with the most intense period of fire activity observed by Moderate Resolution Imaging Spectroradiometer (MODIS). This unfortunate meteorological coincidence allowed transport of polluted air from the region of intense fires to Moscow and the surrounding area. We demonstrate that the 2010 Russian wildfires are unique in the record of observations obtained by remote-sensing instruments on-board NASA satellites: Aura and Aqua (part of the A-Train Constellation) and Terra. Analysis of the distribution of MODIS fire products and aerosol optical thickness (AOT), UV aerosol index (AI) and single-scattering albedo (SSA) from Aura's Ozone Monitoring Instrument (OMI), and total column carbon monoxide (CO) from Aqua s Atmospheric Infrared Sounder (AIRS) show that the region in the center of western Russia surrounding Moscow (52-58 deg N, 33 -43 deg E) is most severely impacted by wildfire emissions. Over this area, AIRS CO, OMI AI, and MODIS AOT are significantly enhanced relative to the historical satellite record during the first 18 days in August when the anti-cyclonic circulation persisted. By mid-August, the anti-cyclonic circulation was replaced with westerly transport over Moscow and vicinity. The heat wave
Salice, Christopher J; Anderson, Todd A; Anderson, Richard H; Olson, Adric D
2018-04-25
Per- and polyfluoroalkyl substances (PFASs) continue to receive significant attention with particular concern for PFASs such as perfluorooctane sulfonate (PFOS) which was a constituent of Aqueous Film-Forming Foam used widely as a fire suppressant for aircraft since the 1970 s. We were interested in the potential for risk to ecological receptors inhabiting Cooper Bayou which is adjacent to two former fire-training areas (FTAs) at Barksdale Air Force Base, LA. Previous research showed higher PFOS concentrations in surface water and biota from Cooper Bayou compared to reference sites. To estimate risk, we compared surface water concentrations from multiple sites within Cooper Bayou to several PFOS chronic toxicity benchmarks for freshwater aquatic organisms (∼0.4-5.1 µg PFOS/L), and showed probility of exceedances from 0.04 to 0.5 suggesting a potential for adverse effects in the most contaminated habitats. A tissue residue assessment similarly showed some exceedance of benchmarks but with with a lower probability (max = 0.17). Both FTAs have been inactive for more than a decade so exposures (and, thus, risks) are expected to decline. Several uncertainties limit confidence in our risk estimates and include, highly dynamic surface water concentrations and limited chronic toxicity data for relevant species. Also, we have little data concerning organisms higher in the food chain which may receive higher lifetime exposures given the potential for PFOS to bioaccumulate and the longevity of many of these organisms. Overall, this study suggests PFOS can occur at concentrations that may cause adverse effects to ecological receptors although additional, focused research is needed to reduce uncertainties. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
2007-01-01
from the Spokane area southwestward to Moses Lake and as far south as the Columbia River . Soils in the channeled scablands can be quite variable...western bluebird, red-necked grebe, great blue heron, turkey vulture, Caspian tern , black tern , and osprey. The white-tailed jackrabbit, a state...frequency are the Spokane Raceway along Hayford Road and firing range activities on FAFB and along the Spokane River . Residential development is
Air Force Groundwater Contamination Cleanup: An Evaluation of the Pump- and-Treat Method.
1988-09-01
Other contaminants commonly detected at Air Force installations are benzene, mercury , pesticides, polychlori- nated biphenyls (PCBs), and Toxaphene...the air base experienced a 3000 gallon fuel (JP-4) spill at Fire Training Area 5 and contracted the DETOX company to conduct cleanup operations. After...several months of pumping, DETOX estimated that only 300 gallons of the fuel had been recovered. Wright-Patterson Air Force Base, unsatisfied with
A Preliminary Investigation on the Application of Robotics to Missile Fire Control.
1983-11-01
application. Even this is a broad area, but it is one in which Okhe general theories and concepts of robo - tics and/or artificial intelligence can be...K::. 3. Expert Advisors .J1. %4. Data Assimilation and Access Aids 5. Handling Support Systems 6. Support Systems 7...appears, therefore, that a robo - tic forward observer can be manufactured in quantities for a reasonable cost when compared to the cost of training
Prediction of forest fires occurrences with area-level Poisson mixed models.
Boubeta, Miguel; Lombardía, María José; Marey-Pérez, Manuel Francisco; Morales, Domingo
2015-05-01
The number of fires in forest areas of Galicia (north-west of Spain) during the summer period is quite high. Local authorities are interested in analyzing the factors that explain this phenomenon. Poisson regression models are good tools for describing and predicting the number of fires per forest areas. This work employs area-level Poisson mixed models for treating real data about fires in forest areas. A parametric bootstrap method is applied for estimating the mean squared errors of fires predictors. The developed methodology and software are applied to a real data set of fires in forest areas of Galicia. Copyright © 2015 Elsevier Ltd. All rights reserved.
2014-03-06
CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters, wearing protective gear, use hoses to put out a fire burning close to a mock-up of a small plane. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett
2014-03-06
CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters, wearing protective gear, use hoses to put out a fire burning near the mock-up of a small plane. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett
2014-03-06
CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters, wearing protective gear, use hoses to put out a fire burning on a mock-up of a small plane. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett
2014-03-06
CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters use fire trucks and hoses to extinguish flames burning on and around a mock-up of a small plane. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett
Large forest fires in Canada, 1959-1997
NASA Astrophysics Data System (ADS)
Stocks, B. J.; Mason, J. A.; Todd, J. B.; Bosch, E. M.; Wotton, B. M.; Amiro, B. D.; Flannigan, M. D.; Hirsch, K. G.; Logan, K. A.; Martell, D. L.; Skinner, W. R.
2002-01-01
A Large Fire Database (LFDB), which includes information on fire location, start date, final size, cause, and suppression action, has been developed for all fires larger than 200 ha in area for Canada for the 1959-1997 period. The LFDB represents only 3.1% of the total number of Canadian fires during this period, the remaining 96.9% of fires being suppressed while <200 ha in size, yet accounts for ˜97% of the total area burned, allowing a spatial and temporal analysis of recent Canadian landscape-scale fire impacts. On average ˜2 million ha burned annually in these large fires, although more than 7 million ha burned in some years. Ecozones in the boreal and taiga regions experienced the greatest areas burned, with an average of 0.7% of the forested land burning annually. Lightning fires predominate in northern Canada, accounting for 80% of the total LFDB area burned. Large fires, although small in number, contribute substantially to area burned, most particularly in the boreal and taiga regions. The Canadian fire season runs from late April through August, with most of the area burned occurring in June and July due primarily to lightning fire activity in northern Canada. Close to 50% of the area burned in Canada is the result of fires that are not actioned due to their remote location, low values-at-risk, and efforts to accommodate the natural role of fire in these ecosystems. The LFDB is updated annually and is being expanded back in time to permit a more thorough analysis of long-term trends in Canadian fire activity.
Large forest fires in Canada, 1959-1997
NASA Astrophysics Data System (ADS)
Stocks, B. J.; Mason, J. A.; Todd, J. B.; Bosch, E. M.; Wotton, B. M.; Amiro, B. D.; Flannigan, M. D.; Hirsch, K. G.; Logan, K. A.; Martell, D. L.; Skinner, W. R.
2003-01-01
A Large Fire Database (LFDB), which includes information on fire location, start date, final size, cause, and suppression action, has been developed for all fires larger than 200 ha in area for Canada for the 1959-1997 period. The LFDB represents only 3.1% of the total number of Canadian fires during this period, the remaining 96.9% of fires being suppressed while <200 ha in size, yet accounts for ~97% of the total area burned, allowing a spatial and temporal analysis of recent Canadian landscape-scale fire impacts. On average ~2 million ha burned annually in these large fires, although more than 7 million ha burned in some years. Ecozones in the boreal and taiga regions experienced the greatest areas burned, with an average of 0.7% of the forested land burning annually. Lightning fires predominate in northern Canada, accounting for 80% of the total LFDB area burned. Large fires, although small in number, contribute substantially to area burned, most particularly in the boreal and taiga regions. The Canadian fire season runs from late April through August, with most of the area burned occurring in June and July due primarily to lightning fire activity in northern Canada. Close to 50% of the area burned in Canada is the result of fires that are not actioned due to their remote location, low values-at-risk, and efforts to accommodate the natural role of fire in these ecosystems. The LFDB is updated annually and is being expanded back in time to permit a more thorough analysis of long-term trends in Canadian fire activity.
Román-Cuesta, María Rosa; Martínez-Vilalta, Jordi
2006-08-01
Since the severe 1982-1983 El Niño drought, recurrent burning has been reported inside tropical protected areas (TPAs). Despite the key role of fire in habitat degradation, little is known about the effectiveness of TPAs in mitigating fire incidence and burned areas. We used a GPS fire database (1995-2005) (n=3590 forest fires) obtained from the National Forest Commission to compare fire incidence (number of fires) and burned areas inside TPAs and their surrounding adjacent buffer areas in Southern Mexico (Chiapas). Burned areas inside parks ranged from 2% (Palenque) to 45% (Lagunas de Montebello) of a park's area, and the amount burned was influenced by two severe El Niño events (1998 and 2003). These two years together resulted in 67% and 46% of the total area burned in TPAs and buffers, respectively during the period under analysis. Larger burned areas in TPAs than in their buffers were exclusively related to the extent of natural habitats (flammable area excluding agrarian and pasture lands). Higher fuel loads together with access and extinction difficulties were likely behind this trend. A higher incidence of fire in TPAs than in their buffers was exclusively related to anthropogenic factors such as higher road densities and agrarian extensions. Our results suggest that TPAs are failing to mitigate fire impacts, with both fire incidence and total burned areas being significantly higher in the reserves than in adjacent buffer areas. Management plans should consider those factors that facilitate fires in TPAs: anthropogenic origin of fires, sensitivity of TPAs to El Niñio-droughts, large fuel loads and fuel continuity inside parks, and limited financial resources. Consideration of these factors favors lines of action such as alternatives to the use of fire (e.g., mucuna-maize system), climatic prediction to follow the evolution of El Niño, fuel management strategies that favor extinction practices, and the strengthening of local communities and ecotourism.
Claar, David V.; Lilly, Michael R.
1997-01-01
Ground-water and surface-water elevation data were collected at 61 sites from 1990 to 1996 by the U.S. Geological Survey in cooperation with the Alaska Department of Transportation and Public Facilities, Fairbanks International Airport. Water-surface elevations were measured in 41 ground-water observation wells and at 20 surface-water sites to help characterize the geohydrology of the Fairbanks International Airport area. From 1990 to 1993, data were collected in the vicinity of the former fire-training area at the airport. From 1993 to 1996, the data-collection area was expanded to include the entire airport area. The total number of data-collection sites varied each year because of changing project objectives and increased understanding of the geohydrology in the area.
2006-08-01
SMP) 1 Trg Area 1330-1430 SMP 2 Trg Area 16 nov 0800-0900 SMP 3 Trg Area 0930-1200 Offensive Fire - LIVE FIRE Range 1 Range Complex 1300-1530 Command...Control Evaluation (C2) 1 Range Complex 1600-1700 SMP 4 Trg Area 17 nov 0930-1200 Defensive Fire - LIVE FIRE Range 2 Range Complex 1300-1530 Command...Control Evaluation (C2) 2 Range Complex 18 nov 0800-0900 SMP 5 Trg Area 0930-1200 Offensive Fire - LIVE FIRE Range 2 Range Complex 1300-1530
Fire Safety of Passenger Trains : Phase II : Application of Fire Hazard Analysis Techniques
DOT National Transportation Integrated Search
2001-12-01
On May 12, 1999, the Federal Railroad Administration (FRA) issued regulations for passenger rail equipment safety standards that included small-scale fire tests and performance criteria to evaluate the flammability and smoke characteristics of indivi...
Fire safety of passenger trains. Phase II, Application of fire hazard analysis techniques.
DOT National Transportation Integrated Search
2001-12-01
On May 12, 1999, the Federal Railroad Administration (FRA) issued regulations for passenger rail equipment safety standards that included small-scale fire tests and performance criteria to evaluate the flammability and smoke characteristics of indivi...
ERIC Educational Resources Information Center
Wright, Dorothy
1999-01-01
Discusses how one college's experience with a tragic fire in one of its residence halls prompted a reevaluation of its fire-prevention-and-response strategies. Staff training, sprinkler installation, new alarm systems, and exit hardware to help make building exiting more efficient are discussed. (GR)
2000-09-14
KENNEDY SPACE CENTER, FLA. -- Firefighters in full gear douse a fire on a simulated aircraft. The firefighters, who are with Fire and Emergency Services at the Naval Station Mayport, Fla., are taking part in fire training exercises at Cape Canaveral Air Force Station Pad 30.
2000-09-14
KENNEDY SPACE CENTER, FLA. -- Firefighters in full gear douse a fire on a simulated aircraft. The firefighters, who are with Fire and Emergency Services at the Naval Station Mayport, Fla., are taking part in fire training exercises at Cape Canaveral Air Force Station Pad 30.
The role of fire in the pan-tropical carbon budget
NASA Astrophysics Data System (ADS)
van der Werf, G.; Randerson, J. T.; Giglio, L.; Baccini, A.; Morton, D. C.; DeFries, R. S.
2012-12-01
Fires are an important management tool in the tropics and subtropics, and are used in the deforestation process, to manage savanna areas, and burn agricultural waste. Satellite-derived datasets of precipitation, aboveground tree biomass, and burned area are now available with over a decade worth of data for precipitation and burned area. Here we used these datasets to assess fire carbon emissions, to better understand relations between interannual variability in precipitation rates and fire activity, and to test ecological hypotheses centered on the role of fire and climate in governing biomass loads in the tropics and subtropics. We show that while most fire carbon emissions are from savanna fires, fires in deforestation regions are crucial from a net carbon emissions perspective and for emissions of reduced trace gases. These tropical fires burning in the dry season increase the amplitude of the CO2 exchange seasonality, in contrast to fires in the boreal region. We then show the large interannual variability of fires and highlight the difference in response of fires to changes in precipitation rates between dry and wet regions. Finally, by studying relations between fire, climate, and biomass, we show that savanna areas that saw fires over the past decade had lower tree biomass than those that did not, but only in medium or high rainfall areas. In areas up to about a meter of rain annually, tree biomass increased monotonically whether there were fires or not. In higher rainfall areas, precipitation seasonality appeared to be a crucial factor in explaining potential biomass. These results show that a world without fires may change the savanna carbon landscape less dramatically than often thought.
Fire Patterns and Drivers of Fires in the West African Tropical Forest
NASA Astrophysics Data System (ADS)
Dwomoh, F. K.; Wimberly, M. C.
2015-12-01
The West African tropical forest (referred to as the Upper Guinean forest, UGF), is a global biodiversity hotspot providing vital ecosystem services for the region's socio-economic and environmental wellbeing. It is also one of the most fragmented and human-modified tropical forest ecosystems, with the only remaining large patches of original forests contained in protected areas. However, these remnant forests are susceptible to continued fire-mediated degradation and forest loss due to intense climatic, demographic and land use pressures. We analyzed human and climatic drivers of fire activity in the sub-region to better understand the spatial and temporal patterns of these risks. We utilized MODIS active fire and burned area products to identify fire activity within the sub-region. We measured climatic variability using TRMM rainfall data and derived indicators of human land use from a variety of geospatial datasets. We used a boosted regression trees model to determine the influences of predictor variables on fire activity. Our analyses indicated that the spatial and temporal variability of precipitation is a key driving factor of fire activity in the UGF. Anthropogenic effects on fire activity in the area were evident through the influences of agriculture and low-density populations. These human footprints in the landscape make forests more susceptible to fires through forest fragmentation, degradation, and fire spread from agricultural areas. Forested protected areas within the forest savanna mosaic experienced frequent fires, whereas the more humid forest areas located in the south and south-western portions of the study area had fewer fires as these rainforests tend to offer some buffering against fire encroachment. These results improve characterization of UGF fire regime and expand our understanding of the spatio-temporal dynamics of tropical forest fires in response to human and climatic pressures.
Fire protection review revisit no. 2, Argonne National Laboratory, Argonne, Illinois
NASA Astrophysics Data System (ADS)
Dobson, P. H.; Earley, M. W.; Mattern, L. J.
1985-05-01
A fire protection survey was conducted at Argonne National Laboratory on April 1-5, 8-12, and April 29-May 2, 1985. The purpose was to review the facility fire protection program and to make recommendations or identify areas according to criteria established by the Department of Energy. There has been a substantial improvement in fire protection at this laboratory since the 1977 audit. Numerous areas which were previously provided with detection systems only have since been provided with automatic sprinkler protection. The following basic fire protection features are not properly controlled: (1) resealing wall and floor penetrations between fire areas after installation of services; (2) cutting and welding; and (3) housekeeping. The present Fire Department manpower level appears adequate to control a route fire. Their ability to adequately handle a high-challenge fire, or one involving injuries to personnel, or fire spread beyond the initial fire area is doubtful.
NASA Astrophysics Data System (ADS)
Urbieta, Itziar R.; Zavala, Gonzalo; Bedia, Joaquín; Gutiérrez, José M.; San Miguel-Ayanz, Jesús; Camia, Andrea; Keeley, Jon E.; Moreno, José M.
2015-11-01
Climate has a strong influence on fire activity, varying across time and space. We analyzed the relationships between fire-weather conditions during the main fire season and antecedent water-balance conditions and fires in two Mediterranean-type regions with contrasted management histories: five southern countries of the European Union (EUMED)(all fires); the Pacific western coast of the USA (California and Oregon, PWUSA)(national forest fires). Total number of fires (≥1 ha), number of large fires (≥100 ha) and area burned were related to mean seasonal fire weather index (FWI), number of days over the 90th percentile of the FWI, and to the standardized precipitation-evapotranspiration index (SPEI) from the preceding 3 (spring) or 8 (autumn through spring) months. Calculations were made at three spatial aggregations in each area, and models related first-difference (year-to-year change) of fires and FWI/climate variables to minimize autocorrelation. An increase in mean seasonal FWI resulted in increases in the three fire variables across spatial scales in both regions. SPEI contributed little to explain fires, with few exceptions. Negative water-balance (dry) conditions from autumn through spring (SPEI8) were generally more important than positive conditions (moist) in spring (SPEI3), both of which contributed positively to fires. The R2 of the models generally improved with increasing area of aggregation. For total number of fires and area burned, the R2 of the models tended to decrease with increasing mean seasonal FWI. Thus, fires were more susceptible to change with climate variability in areas with less amenable conditions for fires (lower FWI) than in areas with higher mean FWI values. The relationships were similar in both regions, albeit weaker in PWUSA, probably due to the wider latitudinal gradient covered in PWUSA than in EUMED. The large variance explained by some of the models indicates that large-scale seasonal forecast could help anticipating fire activity in the investigated areas.
Identity and distribution of residues of energetic compounds at army live-fire training ranges.
Jenkins, Thomas F; Hewitt, Alan D; Grant, Clarence L; Thiboutot, Sonia; Ampleman, Guy; Walsh, Marianne E; Ranney, Thomas A; Ramsey, Charles A; Palazzo, Antonio J; Pennington, Judith C
2006-05-01
Environmental investigations have been conducted at 23 military firing ranges in the United States and Canada. The specific training facilities most frequently evaluated were hand grenade, antitank rocket, and artillery ranges. Energetic compounds (explosives and propellants) were determined and linked to the type of munition used and the major mechanisms of deposition.
STS-40 MS Seddon pauses during fire fighting training at JSC's Fire Pit
1990-08-22
S90-46497 (18 Aug 1990) --- Astronaut Rhea Seddon, STS-40 mission specialist, takes a break from firefighting training at the Johnson Space Center (JSC). In less than a year Dr. Seddon will be joined by four NASA astronauts and two payload specialists for the Spacelab Life Sciences (SLS-1) mission aboard Columbia.
Fire. Youth Training Scheme. Core Exemplar Work Based Project.
ERIC Educational Resources Information Center
Further Education Staff Coll., Blagdon (England).
This trainer's guide is intended to assist supervisors of work-based career training projects in teaching students the basics of fire prevention in the kitchen. The guide is one in a series of core curriculum modules that is intended for use in combination on- and off-the-job programs to familiarize youth with the skills, knowledge, and attitudes…
Gis-Based Multi-Criteria Decision Analysis for Forest Fire Risk Mapping
NASA Astrophysics Data System (ADS)
Akay, A. E.; Erdoğan, A.
2017-11-01
The forested areas along the coastal zone of the Mediterranean region in Turkey are classified as first-degree fire sensitive areas. Forest fires are major environmental disaster that affects the sustainability of forest ecosystems. Besides, forest fires result in important economic losses and even threaten human lives. Thus, it is critical to determine the forested areas with fire risks and thereby minimize the damages on forest resources by taking necessary precaution measures in these areas. The risk of forest fire can be assessed based on various factors such as forest vegetation structures (tree species, crown closure, tree stage), topographic features (slope and aspect), and climatic parameters (temperature, wind). In this study, GIS-based Multi-Criteria Decision Analysis (MCDA) method was used to generate forest fire risk map. The study was implemented in the forested areas within Yayla Forest Enterprise Chiefs at Dursunbey Forest Enterprise Directorate which is classified as first degree fire sensitive area. In the solution process, "extAhp 2.0" plug-in running Analytic Hierarchy Process (AHP) method in ArcGIS 10.4.1 was used to categorize study area under five fire risk classes: extreme risk, high risk, moderate risk, and low risk. The results indicated that 23.81 % of the area was of extreme risk, while 25.81 % was of high risk. The result indicated that the most effective criterion was tree species, followed by tree stages. The aspect had the least effective criterion on forest fire risk. It was revealed that GIS techniques integrated with MCDA methods are effective tools to quickly estimate forest fire risk at low cost. The integration of these factors into GIS can be very useful to determine forested areas with high fire risk and also to plan forestry management after fire.
Inaja Fire - 1956, Pine Hills Fire - 1967...similar, yet different
Mark J. Schroeder; Bernadine B. Taylor
1968-01-01
Two fires burned in the same area in southern California under nearly similar weather conditions, 11 years apart. Yet the Inaja fire of 1956 was much more disastrous than the Pine Hills fire of 1967. The earlier fire claimed 11 lives, and covered an area five times larger than the 1967 fire. Differences in fuels, topography, fire behavior, fire-control action, and...
Solution Focused Empathy Training Groups for Students with Fire-Setting Behaviors
ERIC Educational Resources Information Center
Froeschle, Janet G.
2006-01-01
Fire-setting students are those who intentionally or unintentionally set one or more fires due to curiosity, stress, a need for attention, or due to criminal delinquency. This article describes the nature of fire-setting behaviors, discusses the profile and risk factors associated with the behavior, and outlines a group program using empathy…
ERIC Educational Resources Information Center
Ohio State Univ., Columbus. National Center for Research in Vocational Education.
This military-developed text contains the first three blocks of a five-block course for use in training fire protection specialists. Covered in the individual volumes are the following topics: fire protection objectives and responsibilities (fire protection and occupational safety, extinguishing agents, principles and theory of combustion, natural…
Fuel age and fire spread: Natural conditions versus opportunities for fire suppression
Halsey, Richard W.; Keeley, Jon E.; Wilson, Kit
2009-01-01
Wildfires are driven and restrained by an interplay of variables that can lead to many potential outcomes. As every wildland firefighter learns in basic training, the ability of a fire to spread is determined by three basic variables: fuel type and condition, weather, and topography. Fire suppression obviously plays a significant role in determining fire spread as well, so firefighter activity becomes an additional variable.
78 FR 58967 - Airworthiness Directives; ATR-GIE Avions de Transport Régional Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-25
... extinction and allow fire propagation out of the nacelle fire protected area, resulting in damage to the... efficiency, delay the fire extinction and allow fire propagation out of the nacelle fire protected area... the decrease of the fire extinguishing agent efficiency, which could delay fire extinction and allow...
NASA Astrophysics Data System (ADS)
Tonbul, H.; Kavzoglu, T.
2017-12-01
Forest fires are among the most important natural disasters with the damage to the natural habitat and human-life. Mapping damaged forest fires is crucial for assessing ecological effects caused by fire, monitoring land cover changes and modeling atmospheric and climatic effects of fire. In this context, satellite data provides a great advantage to users by providing a rapid process of detecting burning areas and determining the severity of fire damage. Especially, Mediterranean ecosystems countries sets the suitable conditions for the forest fires. In this study, the determination of burnt areas of forest fire in Pedrógão Grande region of Portugal occurred in June 2017 was carried out using Landsat 8 OLI and Sentinel-2A satellite images. The Pedrógão Grande fire was one of the largest fires in Portugal, more than 60 people was killed and thousands of hectares were ravaged. In this study, four pairs of pre-fire and post-fire top of atmosphere (TOA) and atmospherically corrected images were utilized. The red and near infrared (NIR) spectral bands of pre-fire and post-fire images were stacked and multiresolution segmentation algorithm was applied. In the segmentation processes, the image objects were generated with estimated optimum homogeneity criteria. Using eCognition software, rule sets have been created to distinguish unburned areas from burned areas. In constructing the rule sets, NDVI threshold values were determined pre- and post-fire and areas where vegetation loss was detected using the NDVI difference image. The results showed that both satellite images yielded successful results for burned area discrimination with a very high degree of consistency in terms of spatial overlap and total burned area (over 93%). Object based image analysis (OBIA) was found highly effective in delineation of burnt areas.
AEGIS: a wildfire prevention and management information system
NASA Astrophysics Data System (ADS)
Kalabokidis, K.; Ager, A.; Finney, M.; Athanasis, N.; Palaiologou, P.; Vasilakos, C.
2015-10-01
A Web-GIS wildfire prevention and management platform (AEGIS) was developed as an integrated and easy-to-use decision support tool (http://aegis.aegean.gr). The AEGIS platform assists with early fire warning, fire planning, fire control and coordination of firefighting forces by providing access to information that is essential for wildfire management. Databases were created with spatial and non-spatial data to support key system functionalities. Updated land use/land cover maps were produced by combining field inventory data with high resolution multispectral satellite images (RapidEye) to be used as inputs in fire propagation modeling with the Minimum Travel Time algorithm. End users provide a minimum number of inputs such as fire duration, ignition point and weather information to conduct a fire simulation. AEGIS offers three types of simulations; i.e. single-fire propagations, conditional burn probabilities and at the landscape-level, similar to the FlamMap fire behavior modeling software. Artificial neural networks (ANN) were utilized for wildfire ignition risk assessment based on various parameters, training methods, activation functions, pre-processing methods and network structures. The combination of ANNs and expected burned area maps produced an integrated output map for fire danger prediction. The system also incorporates weather measurements from remote automatic weather stations and weather forecast maps. The structure of the algorithms relies on parallel processing techniques (i.e. High Performance Computing and Cloud Computing) that ensure computational power and speed. All AEGIS functionalities are accessible to authorized end users through a web-based graphical user interface. An innovative mobile application, AEGIS App, acts as a complementary tool to the web-based version of the system.
ESA fire_cci product assessment
NASA Astrophysics Data System (ADS)
Heil, Angelika; Yue, Chao; Mouillot, Florent; Storm, Thomas; Chuvieco, Emilio; Ramo Sanchez, Ruben; Kaiser, Johannes W.
2017-04-01
Vegetation fires are a major disturbance in the Earth System. Fires change the biophysical properties and dynamics of ecosystems and alter terrestrial carbon pools. By altering the atmosphere's composition, fire emissions exert a significant climate forcing. To realistically model past and future changes of the Earth System, fire disturbances must be taken into account. Related modelling efforts require consistent global burned area observations covering at least 10 to 20 years. Guided by the specific requirements of a wide range of end users, the ESA fire_cci project has computed a new global burned area dataset. It applies a newly developed spectral change detection algorithm upon the ENVISAT-MERIS archive. The algorithm relies on MODIS active fire information as "seed". It comprises a pixel burned area product (spatial resolution of 333 m) with date detection information and a biweekly grid product at 0.25 degree spatial resolution. We compare fire_cci burned area with other global burned area products (MCD64 Collection 6, MCD45, GFED4, GFED4s and GEOLAND) and a set of active fires data (hotspots from MODIS, TRMM, AATSR and fire radiative power from GFAS). The analysis of patterns of agreement and disagreement between fire_cci and other products provides a better understanding of product characteristics and uncertainties. The intercomparison of the 2005-2011 fire_cci time series shows a close agreement with GFED4 data in terms of global burned area and the general spatial and temporal patterns. Pronounced differences, however, emerge for specific regions or fire events. Burned area mapped by fire_cci tends to be notably higher in regions where small agricultural fires predominate. The improved detection of small agricultural fires by fire_cci can be related to the increased spatial resolution of the MERIS sensor (333 m compared to 500 in MODIS). This is illustrated in detail using the example of the extreme 2006 spring fires in Eastern Europe.
Safety in the Chemical Laboratory: Advanced Firemanship: How to Teach Your Audience a Lesson.
ERIC Educational Resources Information Center
Pitt, Martin J.
1984-01-01
Provides tips to assist in preparing a training program designed to show that: (1) fire is dangerous; (2) ordinary individuals can neither understand fire nor extinguish it; and (3) a fire safety officer can do both. (JN)
NASA Astrophysics Data System (ADS)
Tambunan, L.; Salamah, H.; Asriana, N.
2017-03-01
This study aims to determine the influence of architectural design on the risk of fire spread in densely urban settlement area. Cellular Automata (CA) is used to analyse the fire spread pattern, speed, and the extent of damage. Four cells represent buildings, streets, and fields characteristic in the simulated area, as well as their flammability level and fire spread capabilities. Two fire scenarios are used to model the spread of fire: (1) fire origin in a building with concrete and wood material majority, and (2) fire origin in building with wood material majority. Building shape, building distance, road width, and total area of wall openings are considered constant, while wind is ignored. The result shows that fire spread faster in the building area with wood majority than with concrete majority. Significant amount of combustible building material, absence of distance between buildings, narrow streets and limited fields are factors which influence fire spread speed and pattern as well as extent of damage when fire occurs in the densely urban settlement area.
High-fire-risk behavior in critical fire areas
William S. Folkman
1977-01-01
Observations of fire-related behavior of wildland visitors were made in three types of areas-wilderness, established campground, and built-up commercial and residential areas-within the San Bernardino National Forest, California. Interviews were conducted with all persons so observed. Types of fire-related behavior differed markedly from one area to another, as did the...
Garcia, Mariano; Saatchi, Sassan; Casas, Angeles; Koltunov, Alexander; Ustin, Susan; Ramirez, Carlos; Garcia-Gutierrez, Jorge; Balzter, Heiko
2017-02-01
Quantifying biomass consumption and carbon release is critical to understanding the role of fires in the carbon cycle and air quality. We present a methodology to estimate the biomass consumed and the carbon released by the California Rim fire by integrating postfire airborne LiDAR and multitemporal Landsat Operational Land Imager (OLI) imagery. First, a support vector regression (SVR) model was trained to estimate the aboveground biomass (AGB) from LiDAR-derived metrics over the unburned area. The selected model estimated AGB with an R 2 of 0.82 and RMSE of 59.98 Mg/ha. Second, LiDAR-based biomass estimates were extrapolated to the entire area before and after the fire, using Landsat OLI reflectance bands, Normalized Difference Infrared Index, and the elevation derived from LiDAR data. The extrapolation was performed using SVR models that resulted in R 2 of 0.73 and 0.79 and RMSE of 87.18 (Mg/ha) and 75.43 (Mg/ha) for the postfire and prefire images, respectively. After removing bias from the AGB extrapolations using a linear relationship between estimated and observed values, we estimated the biomass consumption from postfire LiDAR and prefire Landsat maps to be 6.58 ± 0.03 Tg (10 12 g), which translate into 12.06 ± 0.06 Tg CO2 e released to the atmosphere, equivalent to the annual emissions of 2.57 million cars.
Saatchi, Sassan; Casas, Angeles; Koltunov, Alexander; Ustin, Susan; Ramirez, Carlos; Garcia‐Gutierrez, Jorge; Balzter, Heiko
2017-01-01
Abstract Quantifying biomass consumption and carbon release is critical to understanding the role of fires in the carbon cycle and air quality. We present a methodology to estimate the biomass consumed and the carbon released by the California Rim fire by integrating postfire airborne LiDAR and multitemporal Landsat Operational Land Imager (OLI) imagery. First, a support vector regression (SVR) model was trained to estimate the aboveground biomass (AGB) from LiDAR‐derived metrics over the unburned area. The selected model estimated AGB with an R 2 of 0.82 and RMSE of 59.98 Mg/ha. Second, LiDAR‐based biomass estimates were extrapolated to the entire area before and after the fire, using Landsat OLI reflectance bands, Normalized Difference Infrared Index, and the elevation derived from LiDAR data. The extrapolation was performed using SVR models that resulted in R 2 of 0.73 and 0.79 and RMSE of 87.18 (Mg/ha) and 75.43 (Mg/ha) for the postfire and prefire images, respectively. After removing bias from the AGB extrapolations using a linear relationship between estimated and observed values, we estimated the biomass consumption from postfire LiDAR and prefire Landsat maps to be 6.58 ± 0.03 Tg (1012 g), which translate into 12.06 ± 0.06 Tg CO2e released to the atmosphere, equivalent to the annual emissions of 2.57 million cars. PMID:28405539
AEGIS: a wildfire prevention and management information system
NASA Astrophysics Data System (ADS)
Kalabokidis, Kostas; Ager, Alan; Finney, Mark; Athanasis, Nikos; Palaiologou, Palaiologos; Vasilakos, Christos
2016-03-01
We describe a Web-GIS wildfire prevention and management platform (AEGIS) developed as an integrated and easy-to-use decision support tool to manage wildland fire hazards in Greece (http://aegis.aegean.gr). The AEGIS platform assists with early fire warning, fire planning, fire control and coordination of firefighting forces by providing online access to information that is essential for wildfire management. The system uses a number of spatial and non-spatial data sources to support key system functionalities. Land use/land cover maps were produced by combining field inventory data with high-resolution multispectral satellite images (RapidEye). These data support wildfire simulation tools that allow the users to examine potential fire behavior and hazard with the Minimum Travel Time fire spread algorithm. End-users provide a minimum number of inputs such as fire duration, ignition point and weather information to conduct a fire simulation. AEGIS offers three types of simulations, i.e., single-fire propagation, point-scale calculation of potential fire behavior, and burn probability analysis, similar to the FlamMap fire behavior modeling software. Artificial neural networks (ANNs) were utilized for wildfire ignition risk assessment based on various parameters, training methods, activation functions, pre-processing methods and network structures. The combination of ANNs and expected burned area maps are used to generate integrated output map of fire hazard prediction. The system also incorporates weather information obtained from remote automatic weather stations and weather forecast maps. The system and associated computation algorithms leverage parallel processing techniques (i.e., High Performance Computing and Cloud Computing) that ensure computational power required for real-time application. All AEGIS functionalities are accessible to authorized end-users through a web-based graphical user interface. An innovative smartphone application, AEGIS App, also provides mobile access to the web-based version of the system.
Riley, Karin L.; Loehman, Rachel A.
2016-01-01
Climate changes are expected to increase fire frequency, fire season length, and cumulative area burned in the western United States. We focus on the potential impact of mid-21st-century climate changes on annual burn probability, fire season length, and large fire characteristics including number and size for a study area in the Northern Rocky Mountains. Although large fires are rare they account for most of the area burned in western North America, burn under extreme weather conditions, and exhibit behaviors that preclude methods of direct control. Allocation of resources, development of management plans, and assessment of fire effects on ecosystems all require an understanding of when and where fires are likely to burn, particularly under altered climate regimes that may increase large fire occurrence. We used the large fire simulation model FSim to model ignition, growth, and containment of wildfires under two climate scenarios: contemporary (based on instrumental weather) and mid-century (based on an ensemble average of global climate models driven by the A1B SRES emissions scenario). Modeled changes in fire patterns include increased annual burn probability, particularly in areas of the study region with relatively short contemporary fire return intervals; increased individual fire size and annual area burned; and fewer years without large fires. High fire danger days, represented by threshold values of Energy Release Component (ERC), are projected to increase in number, especially in spring and fall, lengthening the climatic fire season. For fire managers, ERC is an indicator of fire intensity potential and fire economics, with higher ERC thresholds often associated with larger, more expensive fires. Longer periods of elevated ERC may significantly increase the cost and complexity of fire management activities, requiring new strategies to maintain desired ecological conditions and limit fire risk. Increased fire activity (within the historical range of frequency and severity, and depending on the extent to which ecosystems are adapted) may maintain or restore ecosystem functionality; however, in areas that are highly departed from historical fire regimes or where there is disequilibrium between climate and vegetation, ecosystems may be rapidly and persistently altered by wildfires, especially those that burn under extreme conditions.
NASA Astrophysics Data System (ADS)
Yin, Hang; Jin, Hui; Zhao, Ying; Fan, Yuguang; Qin, Liwu; Chen, Qinghong; Huang, Liya; Jia, Xiang; Liu, Lijie; Dai, Yuhong; Xiao, Ying
2018-03-01
The forest-fire not only brings great loss to natural resources, but also destructs the ecosystem and reduces the soil fertility, causing some natural disasters as soil erosion and debris flow. However, due to the lack of the prognosis for forest fire spreading trend in forest fire fighting, it is difficult to formulate rational and effective fire-fighting scheme. In the event of forest fire, achieving accurate judgment to the fire behavior would greatly improve the fire-fighting efficiency, and reduce heavy losses caused by fire. Researches on forest fire spread simulation can effectively reduce the loss of disasters. The present study focused on the simulation of "29 May 2012" wildfire in windthrow area of Changbai Mountain. Basic data were retrieved from the "29 May 2012" wildfire and field survey. A self-development forest fire behavior simulated program based on Rothermel Model was used in the simulation. Kappa coefficient and Sørensen index were employed to evaluate the simulation accuracy. The results showed that: The perimeter of simulated burned area was 4.66 km, the area was 56.47 hm2 and the overlapped burned area was 33.68 hm2, and the estimated rate of fire spread was 0.259 m/s. Between the simulated fire and actual fire, the Kappa coefficient was 0.7398 and the Sørensen co-efficient was 0.7419. This proved the application of Rothermel model to conduct fire behavior simulation in windthrow meadow was feasible. It can achieve the goal of forecasting for the spread behavior in windthrow area of Changbai Mountain. Thus, our self-development program based on the Rothermel model can provide a effective forecast of fire spread, which will facilitate the fire suppression work.
Fire Safety for the Oral and Maxillofacial Surgeon and Surgical Staff.
Di Pasquale, LisaMarie; Ferneini, Elie M
2017-05-01
Fire in the operating room is a life-threatening emergency that demands quick, efficient intervention. Because the circumstances surrounding fires are generally well-understood, virtually every operating room fire is preventable. Before every operating room case, thorough preprocedure "time outs" should address each team members' awareness of specific fire risks and agreement regarding fire concerns and emergency actions. Fire prevention centers on 3 constituent parts of the fire triad necessary for fire formation. Regular fire drills should guide policies and procedures to prevent surgical fires. Delivering optimal patient care in emergent situations requires surgical team training, practicing emergency roles, and specific actions. Copyright © 2016 Elsevier Inc. All rights reserved.
Analysis of weather condition influencing fire regime in Italy
NASA Astrophysics Data System (ADS)
Bacciu, Valentina; Masala, Francesco; Salis, Michele; Sirca, Costantino; Spano, Donatella
2014-05-01
Fires have a crucial role within Mediterranean ecosystems, with both negative and positive impacts on all biosphere components and with reverberations on different scales. Fire determines the landscape structure and plant composition, but it is also the cause of enormous economic and ecological damages, beside the loss of human life. In addition, several authors are in agreement suggesting that, during the past decades, changes on fire patterns have occurred, especially in terms of fire-prone areas expansion and fire season lengthening. Climate and weather are two of the main controlling agents, directly and indirectly, of fire regime influencing vegetation productivity, causing water stress, igniting fires through lightning, or modulating fire behavior through wind. On the other hand, these relationships could be not warranted in areas where most ignitions are caused by people (Moreno et al. 2009). Specific analyses of the driving forces of fire regime across countries and scales are thus still required in order to better anticipate fire seasons and also to advance our knowledge of future fire regimes. The objective of this work was to improve our knowledge of the relative effects of several weather variables on forest fires in Italy for the period 1985-2008. Meteorological data were obtained through the MARS (Monitoring Agricultural Resources) database, interpolated at 25x25 km scale. Fire data were provided by the JRC (Join Research Center) and the CFVA (Corpo Forestale e di Vigilanza Ambientale, Sardinia). A hierarchical cluster analysis, based on fire and weather data, allowed the identification of six homogeneous areas in terms of fire occurrence and climate (pyro-climatic areas). Two statistical techniques (linear and non-parametric models) were applied in order to assess if inter-annual variability in weather pattern and fire events had a significant trend. Then, through correlation analysis and multi-linear regression modeling, we investigated the influence of weather variables on fire activity across a range of time- and spatial-scales. The analysis revealed a general decrease of both number of fires and burned area, although not everywhere with the same magnitude. Overall, regression models where highly significant (p<0.001), and the explained variance ranged from 36% to 80% for fire number and from 37% to 76% for burned area, depending on pyro-climatic area. Moreover, our results contributed in determining the relative importance of climate variables acting at different timescales as control on intrinsic (i.e. flammability and moisture) and extrinsic (i.e. fuel amount and structure) characteristics of vegetation, thus strongly influencing fire occurrence. The good performance of our models, especially in the most fire affected pyro-climatic areas of Italy, and the better understanding of the main driver of fire variability gained through this work could be of great help for fire management among the different pyro-climatic areas.
Urbieta, Itziar R.; Zavala, Gonzalo; Bedia, Joaquin; Gutierrez, Jose M.; San Miguel-Ayanz, Jesus; Camia, Andrea; Keeley, Jon E.; Moreno, Jose M.
2015-01-01
Climate has a strong influence on fire activity, varying across time and space. We analyzed the relationships between fire–weather conditions during the main fire season and antecedent water-balance conditions and fires in two Mediterranean-type regions with contrasted management histories: five southern countries of the European Union (EUMED)(all fires); the Pacific western coast of the USA (California and Oregon, PWUSA)(national forest fires). Total number of fires (≥1 ha), number of large fires (≥100 ha) and area burned were related to mean seasonal fire weather index (FWI), number of days over the 90th percentile of the FWI, and to the standardized precipitation-evapotranspiration index (SPEI) from the preceding 3 (spring) or 8 (autumn through spring) months. Calculations were made at three spatial aggregations in each area, and models related first-difference (year-to-year change) of fires and FWI/climate variables to minimize autocorrelation. An increase in mean seasonal FWI resulted in increases in the three fire variables across spatial scales in both regions. SPEI contributed little to explain fires, with few exceptions. Negative water-balance (dry) conditions from autumn through spring (SPEI8) were generally more important than positive conditions (moist) in spring (SPEI3), both of which contributed positively to fires. The R2 of the models generally improved with increasing area of aggregation. For total number of fires and area burned, the R2 of the models tended to decrease with increasing mean seasonal FWI. Thus, fires were more susceptible to change with climate variability in areas with less amenable conditions for fires (lower FWI) than in areas with higher mean FWI values. The relationships were similar in both regions, albeit weaker in PWUSA, probably due to the wider latitudinal gradient covered in PWUSA than in EUMED. The large variance explained by some of the models indicates that large-scale seasonal forecast could help anticipating fire activity in the investigated areas.
Handbook for Individualized Instruction.
1983-07-01
support of exploratory development task area CF63-521-080-102 (USMC Training and Education), work unit 03.06 (USMC Professional Military Education). The...they did. Example: Suppose the subject is fire support coordination. If a student works a problem and gets the wrong answer, get him or her to walk...the answers that apply. It would be better to say, " Select the one weapon system best able to provide close air support ." Rules 2 and 3 are self
2009-06-01
Figure 2. Examples of surface vegetation at a firing point (inset) and near the crater of an 81-mm mortar projectile low-order detonation on an artillery... mortar impact range.......................... 7 Figure 3. Fort Richardson and surrounding areas...crater where an 81-mm mortar projectile had low-ordered on an impact range. If vegetation is removed or avoided during sampling, energetic residue
NASA Astrophysics Data System (ADS)
McCarty, J. L.; Pouliot, G. A.; Soja, A. J.; Miller, M. E.; Rao, T.
2013-12-01
Prescribed fires in agricultural landscapes generally produce smaller burned areas than wildland fires but are important contributors to emissions impacting air quality and human health. Currently, there are a variety of available satellite-based estimates of crop residue burning, including the NOAA/NESDIS Hazard Mapping System (HMS) the Satellite Mapping Automated Reanalysis Tool for Fire Incident Reconciliation (SMARTFIRE 2), the Moderate Resolution Imaging Spectroradiometer (MODIS) Official Burned Area Product (MCD45A1)), the MODIS Direct Broadcast Burned Area Product (MCD64A1) the MODIS Active Fire Product (MCD14ML), and a regionally-tuned 8-day cropland differenced Normalized Burn Ratio product for the contiguous U.S. The purpose of this NASA-funded research was to refine the regionally-tuned product utilizing higher spatial resolution crop type data from the USDA NASS Cropland Data Layer and burned area training data from field work and high resolution commercial satellite data to improve the U.S. Environmental Protection Agency's (EPA) National Emissions Inventory (NEI). The final product delivered to the EPA included a detailed database of 25 different atmospheric emissions at the county level, emission distributions by crop type and seasonality, and GIS data. The resulting emission databases were shared with the U.S. EPA and regional offices, the National Wildfire Coordinating Group (NWGC) Smoke Committee, and all 48 states in the contiguous U.S., with detailed error estimations for Wyoming and Indiana and detailed analyses of results for Florida, Minnesota, North Dakota, Oklahoma, and Oregon. This work also provided opportunities in discovering the different needs of federal and state partners, including the various geospatial abilities and platforms across the many users and how to incorporate expert air quality, policy, and land management knowledge into quantitative earth observation-based estimations of prescribed fire emissions. Finally, this work created direct communication paths between federal and state partners to the scientists creating the remote sensing-based products, further improving the geospatial products and understanding of air quality impacts of prescribed burning at the state, regional, and national scales.
NASA Astrophysics Data System (ADS)
Bekisz, Marek; Shendye, Ninad; Raciborska, Ida; Wróbel, Andrzej; Waleszczyk, Wioletta J.
2017-08-01
The process of learning induces plastic changes in neuronal network of the brain. Our earlier studies on mice showed that classical conditioning in which monocular visual stimulation was paired with an electric shock to the tail enhanced GABA immunoreactivity within layer 4 of the monocular part of the primary visual cortex (V1), contralaterally to the stimulated eye. In the present experiment we investigated whether the same classical conditioning paradigm induces changes of neuronal excitability in this cortical area. Two experimental groups were used: mice that underwent 7-day visual classical conditioning and controls. Patch-clamp whole-cell recordings were performed from ex vivo slices of mouse V1. The slices were perfused with the modified artificial cerebrospinal fluid, the composition of which better mimics the brain interstitial fluid in situ and induces spontaneous activity. The neuronal excitability was characterized by measuring the frequency of spontaneous action potentials. We found that layer 4 star pyramidal cells located in the monocular representation of the "trained" eye in V1 had lower frequency of spontaneous activity in comparison with neurons from the same cortical region of control animals. Weaker spontaneous firing indicates decreased general excitability of star pyramidal neurons within layer 4 of the monocular representation of the "trained" eye in V1. Such effect could result from enhanced inhibitory processes accompanying learning in this cortical area.
DETERMINATION OF PERFLUOROCARBOXYLATES IN GROUNDWATER IMPACTED BY FIRE-FIGHTING ACTIVITY. (R821195)
Perfluorinated surfactants are used in aqueous film forming foam (AFFF)
formulations, which are used to extinguish hydrocarbon-fuel fires. Virtually
nothing is known about the occurrence of perfluorinated surfactants in the
environment, in particular, at fire-train...
ERIC Educational Resources Information Center
Walker, Bonnie L.
This report describes Phase II of a project which developed a system for delivering fire safety training to board and care providers who serve adults with developmental disabilities. Phase II focused on developing and pilot testing a "train the trainers" workshop for instructors and field testing the provider's workshop. Evaluation of…
ERIC Educational Resources Information Center
International Association of Fire Chiefs, New York, NY.
A course designed to develop performance capabilities in the student of the fire service is presented in a manual. Each chapter is designed to give the student a basic understanding of the material covered in class. Specific objectives are: (1) To train "Support Assistant" B personnel to augment and assist firefighters, (2) To train personnel to…
Altering the Mission Statement: The Training of Firefighters as Intelligence Gatherers
2008-09-01
estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Washington headquarters Services ...distribution is unlimited 12b. DISTRIBUTION CODE A 13. ABSTRACT (maximum 200 words) The fire service is one of the...safety of our communities. 15. NUMBER OF PAGES 71 14. SUBJECT TERMS Fire Service , first responders, intelligence, firefighter training, awareness
2012-03-01
on the standard Navy Handgun Qualification Course. Results partially supported the hypotheses. The simulation group showed greater improvement in MPI...standard Navy Handgun Qualification Course. Results partially supported the hypotheses. The simulation group showed greater improvement in MPI than the...14 3. Navy Handgun Qualification Course Firing Sequence ..................15 F. PROCEDURES
Baduel, Christine; Mueller, Jochen F; Rotander, Anna; Corfield, John; Gomez-Ramos, Maria-José
2017-10-01
Aqueous film forming foams (AFFFs) have been released at fire training facilities for several decades resulting in the contamination of soil and groundwater by per- and polyfluoroalkyl substances (PFASs). AFFF compositions are proprietary and may contain a broad range of PFASs for which the chemical structures and degradation products are not known. In this study, high resolution quadrupole-time-of-flight tandem mass spectrometry (LC-QTOF-MS/MS) in combination with data processing using filtering strategies was applied to characterize and elucidate the PFASs present in concrete extracts collected at a fire training ground after the historical use of various AFFF formulations. Twelve different fluorochemical classes, representing more than 60 chemicals, were detected and identified in the concrete extracts. Novel PFASs homologues, unmonitored before in environmental samples such as chlorinated PFSAs, ketone PFSAs, dichlorinated PFSAs and perfluoroalkane sulphonamides (FASAs) were detected in soil samples collected in the vicinity of the fire training ground. Their detection in the soil cores (from 0 to 2 m) give an insight on the potential mobility of these newly identified PFASs. Copyright © 2017 Elsevier Ltd. All rights reserved.
2014-03-06
CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters, wearing protective gear, use hoses to put out a fire burning near the mock-up of a small plane as another firefighter checks inside the plane. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett
Geoffrey J. Cary; Robert E. Keane; Mike D. Flannigan; Ian D. Davies; Russ A. Parsons
2015-01-01
Understanding what determines area burned in large landscapes is critical for informing wildland fire management in fire-prone environments and for representing fire activity in Dynamic Global Vegetation Models. For the past ten years, a group of landscape-fire modellers have been exploring the relative influence of key determinants of area burned in temperate and...
44 CFR 204.3 - Definitions used throughout this part.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Worksheet. Fire complex. Two or more individual fires located in the same general area, which are assigned.... The ranking official responsible for overseeing the management of fire operations, planning, logistics... existing fire prevention or suppression resources from an area of lower fire danger to one of higher fire...
44 CFR 204.3 - Definitions used throughout this part.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Worksheet. Fire complex. Two or more individual fires located in the same general area, which are assigned.... The ranking official responsible for overseeing the management of fire operations, planning, logistics... existing fire prevention or suppression resources from an area of lower fire danger to one of higher fire...
44 CFR 204.3 - Definitions used throughout this part.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Worksheet. Fire complex. Two or more individual fires located in the same general area, which are assigned.... The ranking official responsible for overseeing the management of fire operations, planning, logistics... existing fire prevention or suppression resources from an area of lower fire danger to one of higher fire...
Pulvinar thalamic nucleus allows for asynchronous spike propagation through the cortex
Cortes, Nelson; van Vreeswijk, Carl
2015-01-01
We create two multilayered feedforward networks composed of excitatory and inhibitory integrate-and-fire neurons in the balanced state to investigate the role of cortico-pulvino-cortical connections. The first network consists of ten feedforward levels where a Poisson spike train with varying firing rate is applied as an input in layer one. Although the balanced state partially avoids spike synchronization during the transmission, the average firing-rate in the last layer either decays or saturates depending on the feedforward pathway gain. The last layer activity is almost independent of the input even for a carefully chosen intermediate gain. Adding connections to the feedforward pathway by a nine areas Pulvinar structure improves the firing-rate propagation to become almost linear among layers. Incoming strong pulvinar spikes balance the low feedforward gain to have a unit input-output relation in the last layer. Pulvinar neurons evoke a bimodal activity depending on the magnitude input: synchronized spike bursts between 20 and 80 Hz and an asynchronous activity for very both low and high frequency inputs. In the first regime, spikes of last feedforward layer neurons are asynchronous with weak, low frequency, oscillations in the rate. Here, the uncorrelated incoming feedforward pathway washes out the synchronized thalamic bursts. In the second regime, spikes in the whole network are asynchronous. As the number of cortical layers increases, long-range pulvinar connections can link directly two or more cortical stages avoiding their either saturation or gradual activity falling. The Pulvinar acts as a shortcut that supplies the input-output firing-rate relationship of two separated cortical areas without changing the strength of connections in the feedforward pathway. PMID:26042026
Tedim, Fantina; Remelgado, Ruben; Martins, João; Carvalho, Salete
2015-01-01
Portugal is a European country with highest forest fires density and burned area. Since beginning of official forest fires database in 1980, an increase in number of fires and burned area as well as appearance of large and catastrophic fires have characterized fire activity in Portugal. In 1980s, the largest fires were just a little bit over 10,000 ha. However, in the beginning of 21st century several fires occurred with a burned area over 20,000 ha. Some of these events can be classified as mega-fires due to their ecological and socioeconomic severity. The present study aimed to discuss the characterization of large forest fires trend, in order to understand if the largest fires that occurred in Portugal were exceptional events or evidences of a new trend, and the constraints of fire size to characterize fire effects because, usually, it is assumed that larger the fire higher the damages. Using Portuguese forest fire database and satellite imagery, the present study showed that the largest fires could be seen at the same time as exceptional events and as evidence of a new fire regime. It highlighted the importance of size and patterns of unburned patches within fire perimeter as well as heterogeneity of fire ecological severity, usually not included in fire regime description, which are critical to fire management and research. The findings of this research can be used in forest risk reduction and suppression planning.
Sprinklers/Standpipes/Detection Systems. Fire Service Certification Series. Unit FSCS-FF-11-80.
ERIC Educational Resources Information Center
Pribyl, Paul F.
This training unit on sprinklers, standpipes, and detection systems is part of a 17-unit course package written to aid instructors in the development, teaching, and evaluation of fire fighters in the Wisconsin Fire Service Certification Series. The purpose stated for the 6-hour unit is to provide the fire fighter with an understanding of the…
2000-09-14
KENNEDY SPACE CENTER, FLA. -- A Mobile Aircraft Fire Trainer vehicle from Naval Station Mayport, Fla., stands by during fire training exercises at Cape Canaveral Air Force Station Pad 30. In the background is the simulated aircraft that was set on fire for the exercise. Firefighters with the Fire and Emergency Services at the Naval Station (in the background) gather around the site of the extinguished flames.
2000-09-14
KENNEDY SPACE CENTER, FLA. -- A Mobile Aircraft Fire Trainer vehicle from Naval Station Mayport, Fla., stands by during fire training exercises at Cape Canaveral Air Force Station Pad 30. In the background is the simulated aircraft that was set on fire for the exercise. Firefighters with the Fire and Emergency Services at the Naval Station (in the background) gather around the site of the extinguished flames.
Saranya, K R L; Reddy, C Sudhakar; Rao, P V V Prasada; Jha, C S
2014-05-01
Analyzing the spatial extent and distribution of forest fires is essential for sustainable forest resource management. There is no comprehensive data existing on forest fires on a regular basis in Biosphere Reserves of India. The present work have been carried out to locate and estimate the spatial extent of forest burnt areas using Resourcesat-1 data and fire frequency covering decadal fire events (2004-2013) in Similipal Biosphere Reserve. The anomalous quantity of forest burnt area was recorded during 2009 as 1,014.7 km(2). There was inconsistency in the fire susceptibility across the different vegetation types. The spatial analysis of burnt area shows that an area of 34.2 % of dry deciduous forests, followed by tree savannah, shrub savannah, and grasslands affected by fires in 2013. The analysis based on decadal time scale satellite data reveals that an area of 2,175.9 km(2) (59.6 % of total vegetation cover) has been affected by varied rate of frequency of forest fires. Fire density pattern indicates low count of burnt area patches in 2013 estimated at 1,017 and high count at 1,916 in 2004. An estimate of fire risk area over a decade identifies 12.2 km(2) is experiencing an annual fire damage. Summing the fire frequency data across the grids (each 1 km(2)) indicates 1,211 (26 %) grids are having very high disturbance regimes due to repeated fires in all the 10 years, followed by 711 grids in 9 years and 418 in 8 years and 382 in 7 years. The spatial database offers excellent opportunities to understand the ecological impact of fires on biodiversity and is helpful in formulating conservation action plans.
A human-driven decline in global burned area
NASA Astrophysics Data System (ADS)
Andela, N.
2017-12-01
Fire regimes are changing rapidly across the globe, driven by human land management and climate. We assessed long-term trends in fire activity using multiple satellite data sets and developed a new global data set on individual fire dynamics to understand the implications of changing fire regimes. Despite warming climate, burned area declined across most of the tropics, contributing to a global decline in burned area of 24.3 ± 8.8% over the past 18 years. The estimated decrease in burned area was largest in savannas and grasslands, where agricultural expansion and intensification were primary drivers of declining fire activity. In tropical forests, frequent fires for deforestation and agricultural management yield a sharp rise in fire activity with the expansion of settled land uses, but the use of fire decreases with increasing investment in agricultural areas in both savanna and forested landscapes. Disparate patterns of recent socieconomic development resulted in contrasting fire trends between southern Africa (increase) and South America (decrease). A strong inverse relationship between burned area and economic development in savannas and grasslands suggests that despite potential increasing fire risk from climate change, ongoing socioeconomic development will likely sustain observed declines in fire in these ecosystems during coming decades. Fewer and smaller fires reduced aerosol concentrations, modified vegetation structure, and increased the magnitude of the terrestrial carbon sink. The spatiotemporal distribution of fire size, duration, speed and direction of spread provided new insights in continental scale differences in fire regimes driven by human and climatic factors. Understanding these dynamics over larger scales is critical to achieve a balance between conservation of fire-dependent ecosystems and increasing agricultural production to support growing populations that will require careful management of fire activity in human-dominated landscapes.
NASA Astrophysics Data System (ADS)
Arca, B.; Salis, M.; Bacciu, V.; Duce, P.; Pellizzaro, G.; Ventura, A.; Spano, D.
2009-04-01
Although in many countries lightning is the main cause of ignition, in the Mediterranean Basin the forest fires are predominantly ignited by arson, or by human negligence. The fire season peaks coincide with extreme weather conditions (mainly strong winds, hot temperatures, low atmospheric water vapour content) and high tourist presence. Many works reported that in the Mediterranean Basin the projected impacts of climate change will cause greater weather variability and extreme weather conditions, with drier and hotter summers and heat waves. At long-term scale, climate changes could affect the fuel load and the dead/live fuel ratio, and therefore could change the vegetation flammability. At short-time scale, the increase of extreme weather events could directly affect fuel water status, and it could increase large fire occurrence. In this context, detecting the areas characterized by both high probability of large fire occurrence and high fire severity could represent an important component of the fire management planning. In this work we compared several fire probability and severity maps (fire occurrence, rate of spread, fireline intensity, flame length) obtained for a study area located in North Sardinia, Italy, using FlamMap simulator (USDA Forest Service, Missoula). FlamMap computes the potential fire behaviour characteristics over a defined landscape for given weather, wind and fuel moisture data. Different weather and fuel moisture scenarios were tested to predict the potential impact of climate changes on fire parameters. The study area, characterized by a mosaic of urban areas, protected areas, and other areas subject to anthropogenic disturbances, is mainly composed by fire-prone Mediterranean maquis. The input themes needed to run FlamMap were input as grid of 10 meters; the wind data, obtained using a computational fluid-dynamic model, were inserted as gridded file, with a resolution of 50 m. The analysis revealed high fire probability and severity in most of the areas, and therefore a high potential danger. The FlamMap outputs and the derived fire probability maps can be used in decision support systems for fire spread and behaviour and for fire danger assessment with actual and future fire regimes.
Ponderosa pine snag densities following multiple fires in the Gila Wilderness, New Mexico
Holden, Z.A.; Morgan, P.; Rollins, M.G.; Wright, R.G.
2006-01-01
Fires create and consume snags (standing dead trees), an important structural and ecological component of ponderosa pine forests. The effects of repeated fires on snag densities in ponderosa pine forests of the southwestern USA have not been studied. Line intercept sampling was used to estimate snag densities in areas of the Gila Wilderness that had burned one to three times under Wildland Fire Use for Resource Benefit (WFU), a fire management policy implemented since 1974 aimed at restoring natural fire regimes. Twenty randomly located transects were measured in areas burned since 1946; six in once-burned areas, six in twice-burned areas and eight in thrice-burned areas. The mean density ?? standard errors of large (>47.5 cm dbh) snags for areas that burned once, twice and thrice was 7.0 ?? 2.7, 4.4 ?? 1.1 and 4.1 ?? 1.3 snags/ha, respectively. Differences in snag densities between once- and multiple-burned areas were significant (F-test; p < 0.05). There was no significant difference in density of large snags between twice- and thrice-burned areas. Proportions of type 1 snags (recently created) were higher in once- and twice-burned areas than in areas that burned three times, likely reflecting high tree mortality and snag recruitment resulting from an initial entry fire. Type 3 snags (charred by previous fire) were more abundant in areas that burned multiple times. The lack of differences in snag densities between areas that burned two and three times suggests that repeated fires leave many snags standing. The increasing proportion of type 3 snags with repeated fires supports this conclusion. ?? 2005 Elsevier B.V. All rights reserved.
Bukowski, Beth E; Baker, William L
2013-04-01
Sagebrush landscapes provide habitat for Sage-Grouse and other sagebrush obligates, yet historical fire regimes and the structure of historical sagebrush landscapes are poorly known, hampering ecological restoration and management. To remedy this, General Land Office Survey (GLO) survey notes were used to reconstruct over two million hectares of historical vegetation for four sagebrush-dominated (Artemisia spp.) study areas in the western United States. Reconstructed vegetation was analyzed for fire indicators used to identify historical fires and reconstruct historical fire regimes. Historical fire-size distributions were inverse-J shaped, and one fire > 100 000 ha was identified. Historical fire rotations were estimated at 171-342 years for Wyoming big sagebrush (A. tridentata ssp. wyomingensis) and 137-217 years for mountain big sagebrush (A. tridentata ssp. vaseyana). Historical fire and patch sizes were significantly larger in Wyoming big sagebrush than mountain big sagebrush, and historical fire rotations were significantly longer in Wyoming big sagebrush than mountain big sagebrush. Historical fire rotations in Wyoming were longer than those in other study areas. Fine-scale mosaics of burned and unburned area and larger unburned inclusions within fire perimeters were less common than in modern fires. Historical sagebrush landscapes were dominated by large, contiguous areas of sagebrush, though large grass-dominated areas and finer-scale mosaics of grass and sagebrush were also present in smaller amounts. Variation in sagebrush density was a common source of patchiness, and areas classified as "dense" made up 24.5% of total sagebrush area, compared to 16.3% for "scattered" sagebrush. Results suggest significant differences in historical and modern fire regimes. Modern fire rotations in Wyoming big sagebrush are shorter than historical fire rotations. Results also suggest that historical sagebrush landscapes would have fluctuated, because of infrequent episodes of large fires and long periods of recovery and maturity. Due to fragmentation of sagebrush landscapes, the large, contiguous expanses of sagebrush that dominated historically are most at risk and in need of conservation, including both dense and scattered sagebrush. Fire suppression in Wyoming big sagebrush may also be advisable, as modern fire rotations are shorter than their historical counterparts.
NASA Astrophysics Data System (ADS)
Davies, D.; Wong, M.; Ilavajhala, S.; Molinario, G.; Justice, C. O.
2012-12-01
This paper discusses the broad uptake of MODIS near-real-time (NRT) active fire data for applications. Prior to the launch of MODIS most real-time satellite-derived fire information was obtained from NOAA AVHRR via direct broadcast (DB) systems. Whilst there were efforts to make direct broadcast stations affordable in developing countries, such as through the Local Applications of Satellite Remote Technologies (LARST), these systems were relatively few and far between and required expertise to manage and operate. One such system was in Etosha National Park (ENP) in Namibia. Prior to the installation of the AVHRR DB system in ENP, fires were reported by rangers and the quality, accuracy and timing of reports was variable. With the introduction of the DB station, early warning of fires improved and fire maps could be produced for park managers within 2-3 hours by staff trained to process data, interpret images and produce maps. Up keep and maintenance of such systems was relatively costly for parks with limited resources therefore when global fire data from MODIS became available uptake was widespread. NRT data from MODIS became availalbe through a collaboration between the MODIS Fire Team and the US Forest Service (USFS) Remote Sensing Applications Center to provide rapid access to imagery to help fight the Montana wildfires of 2001. This prompted the development of a Rapid Response System for fire data that eventually led to the operational use of MODIS data by the USFS for fire monitoring. Building on this success, the Fire Information for Resource Management System (FIRMS) project was funded by NASA Applications, and developed under the umbrella of the GOFC-GOLD Fire program, to further improve products and services for the global fire information community. FIRMS was developed as a web-based geospatial tool, offering a range of geospatial data services, including a fire email alert service which is widely used around the world. FIRMS was initially developed to meet the needs of protected area managers, who like the managers in ENP had limited resources to cover large, remote areas. It was quickly realized that these data could be used for a wide range of applications beyond wildfire management including ecological studies, informing fire policy and public outreach. Today, FIRMS sends approximately 2000 email alerts daily to users in over 120 countries. In addition to the direct users of the MODIS fire data, there are a growing number of brokers who add value to the data, by combining them with targeted geospatial information and re-distribute the information. In addition to the English, French and Spanish fire notifications sent out by FIRMS, some brokers translate the alerts in to local languages and distribute them in Thailand, Indonesia, Russia and India.
2014-03-06
CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida practice firefighting skills at the Shuttle Landing Facility. A firefighter dons protective gear to prepare for the training simulation. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett
Climate, lightning ignitions, and fire severity in Yosemite National Park, California, USA
Lutz, J.A.; van Wagtendonk, J.W.; Thode, A.E.; Miller, J.D.; Franklin, J.F.
2009-01-01
Continental-scale studies of western North America have attributed recent increases in annual area burned and fire size to a warming climate, but these studies have focussed on large fires and have left the issues of fire severity and ignition frequency unaddressed. Lightning ignitions, any of which could burn a large area given appropriate conditions for fire spread, could be the first indication of more frequent fire. We examined the relationship between snowpack and the ignition and size of fires that occurred in Yosemite National Park, California (area 3027 km2), between 1984 and 2005. During this period, 1870 fires burned 77 718 ha. Decreased spring snowpack exponentially increased the number of lightning-ignited fires. Snowpack mediated lightning-ignited fires by decreasing the proportion of lightning strikes that caused lightning-ignited fires and through fewer lightning strikes in years with deep snowpack. We also quantified fire severity for the 103 fires >40 ha with satellite fire-severity indices using 23 years of Landsat Thematic Mapper data. The proportion of the landscape that burned at higher severities and the complexity of higher-severity burn patches increased with the log10 of annual area burned. Using one snowpack forecast, we project that the number of lightning-ignited fires will increase 19.1% by 2020 to 2049 and the annual area burned at high severity will increase 21.9%. Climate-induced decreases in snowpack and the concomitant increase in fire severity suggest that existing assumptions may be understated-fires may become more frequent and more severe. ?? IAWF 2009.
Fire growth maps for the 1988 Greater Yellowstone Area Fires
Richard C. Rothermel; Roberta A Hartford; Carolyn H. Chase
1994-01-01
Daily fire growth maps display the growth of the 1988 fires in the Greater Yellowstone Area. Information and data sources included daily infrared photography flights, satellite imagery, ground and aerial reconnaissance, command center intelligence, and the personal recollections of fire behavior observers. Fire position was digitized from topographic maps using GRASS...
Grabinski, Christin M; Methner, Mark M; Jackson, Jerimiah M; Moore, Alexander L; Flory, Laura E; Tilly, Trevor; Hussain, Saber M; Ott, Darrin K
2017-06-01
U.S. Air Force small arms firing ranges began using copper-based, lead-free frangible ammunition in the early 2000s due to environmental and health concerns related to the use of lead-based ammunition. Exposure assessments at these firing ranges have routinely detected chemicals and metals in amounts much lower than their mass-based occupational exposure limits, yet, instructors report work-related health concerns including respiratory distress, nausea, and headache. The objective of this study at one firing range was to characterize the aerosol emissions produced by weapons during firing events and evaluate the ventilation system's effectiveness in controlling instructor exposure to these emissions. The ventilation system was assessed by measuring the range static air pressure differential and the air velocity at the firing line. Air flow patterns were near the firing line. Instructor exposure was sampled using a filter-based air sampling method for metals and a wearable, real-time ultrafine particle counter. Area air sampling was simultaneously performed to characterize the particle size distribution, morphology, and composition. In the instructor's breathing zone, the airborne mass concentration of copper was low (range = <1 µg/m 3 to 16 µg/m 3 ), yet the ultrafine (nanoscale) particle number concentration increased substantially during each firing event. Ultrafine particles contained some copper and were complex in morphology and composition. The ventilation assessment found that the average velocity across all shooting lanes was acceptable compared to the recommended guideline (20% of the ideal 0.38 m/s (75 ft/min). However, uniform, downrange airflow pattern requirements were not met. These results suggest that the mass-based occupational exposure limits, as applied to this environment, may not be protective enough to eliminate health complaints reported by instructors whose full-time job involves training personnel on weapons that fire lead-free frangible ammunition. Using an ultrafine particle counter appears to be an alternative method of assessing ventilation effectiveness in removing ultrafine particulate produced during firing events.
Tarimo, Beatrice; Dick, Øystein B; Gobakken, Terje; Totland, Ørjan
2015-12-01
Anthropogenic uses of fire play a key role in regulating fire regimes in African savannas. These fires contribute the highest proportion of the globally burned area, substantial biomass burning emissions and threaten maintenance and enhancement of carbon stocks. An understanding of fire regimes at local scales is required for the estimation and prediction of the contribution of these fires to the global carbon cycle and for fire management. We assessed the spatio-temporal distribution of fires in miombo woodlands of Tanzania, utilizing the MODIS active fire product and Landsat satellite images for the past ~40 years. Our results show that up to 50.6% of the woodland area is affected by fire each year. An early and a late dry season peak in wetter and drier miombo, respectively, characterize the annual fire season. Wetter miombo areas have higher fire activity within a shorter annual fire season and have shorter return intervals. The fire regime is characterized by small-sized fires, with a higher ratio of small than large burned areas in the frequency-size distribution (β = 2.16 ± 0.04). Large-sized fires are rare, and occur more frequently in drier than in wetter miombo. Both fire prevalence and burned extents have decreased in the past decade. At a large scale, more than half of the woodland area has less than 2 years of fire return intervals, which prevent the occurrence of large intense fires. The sizes of fires, season of burning and spatial extent of occurrence are generally consistent across time, at the scale of the current analysis. Where traditional use of fire is restricted, a reassessment of fire management strategies may be required, if sustainability of tree cover is a priority. In such cases, there is a need to combine traditional and contemporary fire management practices.
Projecting climate-driven increases in North American fire activity
NASA Astrophysics Data System (ADS)
Wang, D.; Morton, D. C.; Collatz, G. J.
2013-12-01
Climate regulates fire activity through controls on vegetation productivity (fuels), lightning ignitions, and conditions governing fire spread. In many regions of the world, human management also influences the timing, duration, and extent of fire activity. These coupled interactions between human and natural systems make fire a complex component of the Earth system. Satellite data provide valuable information on the spatial and temporal dynamics of recent fire activity, as active fires, burned area, and land cover information can be combined to separate wildfires from intentional burning for agriculture and forestry. Here, we combined satellite-derived burned area data with land cover and climate data to assess fire-climate relationships in North America between 2000-2012. We used the latest versions of the Global Fire Emissions Database (GFED) burned area product and Modern-Era Retrospective Analysis for Research and Applications (MERRA) climate data to develop regional relationships between burned area and potential evaporation (PE), an integrated dryness metric. Logistic regression models were developed to link burned area with PE and individual climate variables during and preceding the fire season, and optimal models were selected based on Akaike Information Criterion (AIC). Overall, our model explained 85% of the variance in burned area since 2000 across North America. Fire-climate relationships from the era of satellite observations provide a blueprint for potential changes in fire activity under scenarios of climate change. We used that blueprint to evaluate potential changes in fire activity over the next 50 years based on twenty models from the Coupled Model Intercomparison Project Phase 5 (CMIP5). All models suggest an increase of PE under low and high emissions scenarios (Representative Concentration Pathways (RCP) 4.5 and 8.5, respectively), with largest increases in projected burned area across the western US and central Canada. Overall, near-term climate projections point to pronounced changes in fire season length, total burned area, and the frequency of extreme events across North America by 2050.
High resolution fire risk mapping in Italy
NASA Astrophysics Data System (ADS)
Fiorucci, Paolo; Biondi, Guido; Campo, Lorenzo; D'Andrea, Mirko
2014-05-01
The high topographic and vegetation heterogeneity makes Italy vulnerable to forest fires both in the summer and in winter. In particular, northern regions are predominantly characterized by a winter fire regime, mainly due to frequent extremely dry winds from the north, while southern and central regions and the large islands are characterized by a severe summer fire regime, because of the higher temperatures and prolonged lack of precipitation. The threat of wildfires in Italy is not confined to wooded areas as they extend to agricultural areas and urban-forest interface areas. The agricultural and rural areas, in the last century, have been gradually abandoned, especially in areas with complex topography. Many of these areas were subject to reforestation, leading to the spread of pioneer species mainly represented by Mediterranean conifer, which are highly vulnerable to fire. Because of the frequent spread of fire, these areas are limited to the early successional stages, consisting mainly of shrub vegetation; its survival in the competition with the climax species being ensured by the spread of fire itself. Due to the frequency of fire ignition — almost entirely man caused — the time between fires on the same area is at least an order of magnitude less than the time that would allow the establishment of forest climax species far less vulnerable to fire. In view of the limited availability of fire risk management resources, most of which are used in the management of national and regional air services, it is necessary to precisely identify the areas most vulnerable to fire risk. The few resources available can thus be used on a yearly basis to mitigate problems in the areas at highest risk by defining a program of forest management interventions, which is expected to make a significant contribution to the problem in a few years' time. The goal of such detailed planning is to dramatically reduce the costs associated with water bombers fleet management and fire extinguishing actions, leaving more resources to improve safety in areas at risk. With the availability of fire perimeters mapped over a period spanning from 5 to 10 years, depending by the region, a procedure was defined in order to assess areas at risk with high spatial resolution (900 m2) based on objective criteria by observing past fire events. The availability of fire perimeters combined with a detailed knowledge of topography and land cover allowed to understand which are the main features involved in forest fire occurrences and their behaviour. The seasonality of the fire regime was also considered, partitioning the analysis in two macro season (November- April and May- October). In addition, the total precipitation obtained from the interpolation of 30 years-long time series from 460 raingauges and the average air temperature obtained downscaling 30 years ERA-INTERIM data series were considered. About 48000 fire perimeters which burnt about 5500 km2 were considered in the analysis. The analysis has been carried out at 30 m spatial resolution. Some important considerations relating to climate and the territorial features that characterize the fire regime at national level contribute to better understand the forest fire phenomena. These results allow to define new strategies for forest fire prevention and management extensible to other geographical areas.
Thetford plastics fire, October 1991: the role of a preventive medical team in chemical incidents.
Baxter, P J; Heap, B J; Rowland, M G; Murray, V S
1995-01-01
OBJECTIVES--To review the role of a medical team in the emergency management of a major polyvinyl chloride (PVC) fire in an urban area. METHODS--The district health authority's consultant in communicable disease control (CCDC) was requested to advise on the health impacts of a fire that consumed some 1000 tonnes of plastic, mainly PVC, over 72 hours and which emitted a large smoke plume that threatened the health of local residents and emergency workers alike, constituting one of the largest incidents the local emergency services had dealt with in recent years. A medical team was formed comprising the CCDC, a regional epidemiologist, an occupational physician, and a medical toxicologist. This paper is an account of this team's experience of advising on the medical management of the emergency without having any formally established role or previous training for the task. RESULTS--The main issues requiring the input of the medical team included: the possible products of combustion and their effects on health; the clinical management of those exposed; the alerting of local hospitals to the type of casualties to expect; the special health risks posed to emergency workers, especially the firemen; the need for evacuation of local residents; the risks of contamination of soil, water, and crops; the potential health impact of the plume; and the provision of expert and authoritative advice on the short and long term health implications to the public. Active surveillance systems, which included the local general practitioners and hospitals, were established and air monitoring instigated. The 46 casualties were restricted to emergency personnel who had inadvertently received exposure to the fire smoke: all recovered within 48 hours. Local residents were unharmed. CONCLUSION--The incident showed the need for preventive medical teams trained to fill a formal advisory and investigative role for chemical releases and fires, and which can play an integral part in emergency management. PMID:7489061
Thetford plastics fire, October 1991: the role of a preventive medical team in chemical incidents.
Baxter, P J; Heap, B J; Rowland, M G; Murray, V S
1995-10-01
To review the role of a medical team in the emergency management of a major polyvinyl chloride (PVC) fire in an urban area. The district health authority's consultant in communicable disease control (CCDC) was requested to advise on the health impacts of a fire that consumed some 1000 tonnes of plastic, mainly PVC, over 72 hours and which emitted a large smoke plume that threatened the health of local residents and emergency workers alike, constituting one of the largest incidents the local emergency services had dealt with in recent years. A medical team was formed comprising the CCDC, a regional epidemiologist, an occupational physician, and a medical toxicologist. This paper is an account of this team's experience of advising on the medical management of the emergency without having any formally established role or previous training for the task. The main issues requiring the input of the medical team included: the possible products of combustion and their effects on health; the clinical management of those exposed; the alerting of local hospitals to the type of casualties to expect; the special health risks posed to emergency workers, especially the firemen; the need for evacuation of local residents; the risks of contamination of soil, water, and crops; the potential health impact of the plume; and the provision of expert and authoritative advice on the short and long term health implications to the public. Active surveillance systems, which included the local general practitioners and hospitals, were established and air monitoring instigated. The 46 casualties were restricted to emergency personnel who had inadvertently received exposure to the fire smoke: all recovered within 48 hours. Local residents were unharmed. The incident showed the need for preventive medical teams trained to fill a formal advisory and investigative role for chemical releases and fires, and which can play an integral part in emergency management.
Trends and causes of severity, size, and number of fires in northwestern California, USA.
Miller, J D; Skinner, C N; Safford, H D; Knapp, E E; Ramirez, C M
2012-01-01
Research in the last several years has indicated that fire size and frequency are on the rise in western U.S. forests. Although fire size and frequency are important, they do not necessarily scale with ecosystem effects of fire, as different ecosystems have different ecological and evolutionary relationships with fire. Our study assessed trends and patterns in fire size and frequency from 1910 to 2008 (all fires > 40 ha), and the percentage of high-severity in fires from 1987 to 2008 (all fires > 400 ha) on the four national forests of northwestern California. During 1910-2008, mean and maximum fire size and total annual area burned increased, but we found no temporal trend in the percentage of high-severity fire during 1987-2008. The time series of severity data was strongly influenced by four years with region-wide lightning events that burned huge areas at primarily low-moderate severity. Regional fire rotation reached a high of 974 years in 1984 and fell to 95 years by 2008. The percentage of high-severity fire in conifer-dominated forests was generally higher in areas dominated by smaller-diameter trees than in areas with larger-diameter trees. For Douglas-fir forests, the percentage of high-severity fire did not differ significantly between areas that re-burned and areas that only burned once (10% vs. 9%) when re-burned within 30 years. Percentage of high-severity fire decreased to 5% when intervals between first and second fires were > 30 years. In contrast, in both mixed-conifer and fir/high-elevation conifer forests, the percentage of high-severity fire was less when re-burned within 30 years compared to first-time burned (12% vs. 16% for mixed conifer; 11% vs. 19% for fir/high-elevation conifer). Additionally, the percentage of high-severity fire did not differ whether the re-burn interval was less than or greater than 30 years. Years with larger fires and greatest area burned were produced by region-wide lightning events, and characterized by less winter and spring precipitation than years dominated by smaller human-ignited fires. Overall percentage of high-severity fire was generally less in years characterized by these region-wide lightning events. Our results suggest that, under certain conditions, wildfires could be more extensively used to achieve ecological and management objectives in northwestern California.
Using Matrix and Tensor Factorizations for the Single-Trial Analysis of Population Spike Trains.
Onken, Arno; Liu, Jian K; Karunasekara, P P Chamanthi R; Delis, Ioannis; Gollisch, Tim; Panzeri, Stefano
2016-11-01
Advances in neuronal recording techniques are leading to ever larger numbers of simultaneously monitored neurons. This poses the important analytical challenge of how to capture compactly all sensory information that neural population codes carry in their spatial dimension (differences in stimulus tuning across neurons at different locations), in their temporal dimension (temporal neural response variations), or in their combination (temporally coordinated neural population firing). Here we investigate the utility of tensor factorizations of population spike trains along space and time. These factorizations decompose a dataset of single-trial population spike trains into spatial firing patterns (combinations of neurons firing together), temporal firing patterns (temporal activation of these groups of neurons) and trial-dependent activation coefficients (strength of recruitment of such neural patterns on each trial). We validated various factorization methods on simulated data and on populations of ganglion cells simultaneously recorded in the salamander retina. We found that single-trial tensor space-by-time decompositions provided low-dimensional data-robust representations of spike trains that capture efficiently both their spatial and temporal information about sensory stimuli. Tensor decompositions with orthogonality constraints were the most efficient in extracting sensory information, whereas non-negative tensor decompositions worked well even on non-independent and overlapping spike patterns, and retrieved informative firing patterns expressed by the same population in response to novel stimuli. Our method showed that populations of retinal ganglion cells carried information in their spike timing on the ten-milliseconds-scale about spatial details of natural images. This information could not be recovered from the spike counts of these cells. First-spike latencies carried the majority of information provided by the whole spike train about fine-scale image features, and supplied almost as much information about coarse natural image features as firing rates. Together, these results highlight the importance of spike timing, and particularly of first-spike latencies, in retinal coding.
Using Matrix and Tensor Factorizations for the Single-Trial Analysis of Population Spike Trains
Onken, Arno; Liu, Jian K.; Karunasekara, P. P. Chamanthi R.; Delis, Ioannis; Gollisch, Tim; Panzeri, Stefano
2016-01-01
Advances in neuronal recording techniques are leading to ever larger numbers of simultaneously monitored neurons. This poses the important analytical challenge of how to capture compactly all sensory information that neural population codes carry in their spatial dimension (differences in stimulus tuning across neurons at different locations), in their temporal dimension (temporal neural response variations), or in their combination (temporally coordinated neural population firing). Here we investigate the utility of tensor factorizations of population spike trains along space and time. These factorizations decompose a dataset of single-trial population spike trains into spatial firing patterns (combinations of neurons firing together), temporal firing patterns (temporal activation of these groups of neurons) and trial-dependent activation coefficients (strength of recruitment of such neural patterns on each trial). We validated various factorization methods on simulated data and on populations of ganglion cells simultaneously recorded in the salamander retina. We found that single-trial tensor space-by-time decompositions provided low-dimensional data-robust representations of spike trains that capture efficiently both their spatial and temporal information about sensory stimuli. Tensor decompositions with orthogonality constraints were the most efficient in extracting sensory information, whereas non-negative tensor decompositions worked well even on non-independent and overlapping spike patterns, and retrieved informative firing patterns expressed by the same population in response to novel stimuli. Our method showed that populations of retinal ganglion cells carried information in their spike timing on the ten-milliseconds-scale about spatial details of natural images. This information could not be recovered from the spike counts of these cells. First-spike latencies carried the majority of information provided by the whole spike train about fine-scale image features, and supplied almost as much information about coarse natural image features as firing rates. Together, these results highlight the importance of spike timing, and particularly of first-spike latencies, in retinal coding. PMID:27814363
ESA Fire CCI product assessment
NASA Astrophysics Data System (ADS)
Heil, Angelika; Yue, Chao; Mouillot, Florent; Storm, Thomas; Chuvieco, Emilio; Kaiser, Johannes
2016-04-01
Vegetation fires are a major disturbance in the Earth System. Fires change the biophysical properties and dynamics of ecosystems and alter terrestrial carbon pools. By altering the atmosphere's composition, fire emissions exert a significant climate forcing. To realistically model past and future changes of the Earth System, fire disturbances must be taken into account. Related modelling efforts require consistent global burned area observations covering at least 10 to 20 years. Guided by the specific requirements of a wide range of end users, the ESA fire_cci project is currently computing a new global burned area dataset. It applies a newly developed spectral change detection algorithm upon the full ENVISAT-MERIS archive (2002 to 2012). The algorithm relies on MODIS active fire information as "seed". A first, formally validated version has been released for the period 2006 to 2008. It comprises a pixel burned area product (spatial resolution of 333 m) with date detection information and a biweekly grid product at 0.5 degree spatial resolution. We compare fire_cci burned area with other global burned area products (MCD64, GFED4(s), GEOLAND) and a set of active fires data (hotspots from MODIS, TRMM, AATSR and fire radiative power from GFAS). Output from the ongoing processing of the full MERIS timeseries will be incorporated into the study, as far as available. The analysis of patterns of agreement and disagreement between fire_cci and other products provides a better understanding of product characteristics and uncertainties. The intercomparison of the 2006-2008 fire_cci time series shows a close agreement with GFED4 data in terms of global burned area and the general spatial and temporal patterns. Pronounced differences, however, emerge for specific regions or fire events. Burned area mapped by fire_cci tends to be notably higher in regions where small agricultural fires predominate. The improved detection of small agricultural fires by fire_cci can be related to the increased spatial resolution of the MERIS sensor (333 m compared to 500 in MODIS). This is illustrated in detail using the example of the extreme 2006 spring fires in Eastern Europe.
Automated integration of lidar into the LANDFIRE product suite
Peterson, Birgit; Nelson, Kurtis; Seielstad, Carl; Stoker, Jason M.; Jolly, W. Matt; Parsons, Russell
2015-01-01
Accurate information about three-dimensional canopy structure and wildland fuel across the landscape is necessary for fire behaviour modelling system predictions. Remotely sensed data are invaluable for assessing these canopy characteristics over large areas; lidar data, in particular, are uniquely suited for quantifying three-dimensional canopy structure. Although lidar data are increasingly available, they have rarely been applied to wildland fuels mapping efforts, mostly due to two issues. First, the Landscape Fire and Resource Planning Tools (LANDFIRE) program, which has become the default source of large-scale fire behaviour modelling inputs for the US, does not currently incorporate lidar data into the vegetation and fuel mapping process because spatially continuous lidar data are not available at the national scale. Second, while lidar data are available for many land management units across the US, these data are underutilized for fire behaviour applications. This is partly due to a lack of local personnel trained to process and analyse lidar data. This investigation addresses these issues by developing the Creating Hybrid Structure from LANDFIRE/lidar Combinations (CHISLIC) tool. CHISLIC allows individuals to automatically generate a suite of vegetation structure and wildland fuel parameters from lidar data and infuse them into existing LANDFIRE data sets. CHISLIC will become available for wider distribution to the public through a partnership with the U.S. Forest Service’s Wildland Fire Assessment System (WFAS) and may be incorporated into the Wildland Fire Decision Support System (WFDSS) with additional design and testing. WFAS and WFDSS are the primary systems used to support tactical and strategic wildland fire management decisions.
2011-12-01
Pennsylvania Emergency Management Agency QHSR Quadrennial Homeland Security Review Report RCP Regional Catastrophic Preparedness SAA State...service has evolved from a single-purpose service focused on controlling fires to a multidimensional response element responsible for pre- hospital ... hospital preparedness program Preparedness Training for all personnel; training and network activities during prior year assist in preparedness
Fire Fighter Trainer Environmental Considerations
1981-01-08
established by the Environmental Protection Agency and various state and local ordinances. At present, the Navy’s fire fighter train- ing facilities use...necessary. All operational capabilities for military communications equipment have been retained. Each training compartment has a local communications...the state or local air pollution-control agencies on a case-by-case basis. 4.2.4 Japanese Air Pollution-Control Regulations. The Japanese Air Quality
Assessing Landscape Scale Wildfire Exposure for Highly Valued Resources in a Mediterranean Area
NASA Astrophysics Data System (ADS)
Alcasena, Fermín J.; Salis, Michele; Ager, Alan A.; Arca, Bachisio; Molina, Domingo; Spano, Donatella
2015-05-01
We used a fire simulation modeling approach to assess landscape scale wildfire exposure for highly valued resources and assets (HVR) on a fire-prone area of 680 km2 located in central Sardinia, Italy. The study area was affected by several wildfires in the last half century: some large and intense fire events threatened wildland urban interfaces as well as other socioeconomic and cultural values. Historical wildfire and weather data were used to inform wildfire simulations, which were based on the minimum travel time algorithm as implemented in FlamMap. We simulated 90,000 fires that replicated recent large fire events in the area spreading under severe weather conditions to generate detailed maps of wildfire likelihood and intensity. Then, we linked fire modeling outputs to a geospatial risk assessment framework focusing on buffer areas around HVR. The results highlighted a large variation in burn probability and fire intensity in the vicinity of HVRs, and allowed us to identify the areas most exposed to wildfires and thus to a higher potential damage. Fire intensity in the HVR buffers was mainly related to fuel types, while wind direction, topographic features, and historically based ignition pattern were the key factors affecting fire likelihood. The methodology presented in this work can have numerous applications, in the study area and elsewhere, particularly to address and inform fire risk management, landscape planning and people safety on the vicinity of HVRs.
Fire and Life Safety Training Needs of Rail Rapid Transit System and Fire Service Personnel
DOT National Transportation Integrated Search
1983-05-01
This report presents a summary and the results of the successful workshop "On Track to Fire and Life Safety in Rail Rapid Transit," held on August 2-4, 1982, at Crystal City, Virginia. Sponsored by the Urban Mass Transportation Administration (UMTA) ...
Industrial Fire Brigade Training.
ERIC Educational Resources Information Center
North Carolina State Dept. of Community Colleges, Raleigh.
Organized as a teaching outline for an industrial plant fire brigade course, this manual contains a rationale for an industrial plant brigade as an adjunct to the local firefighting services; information to the instructor concerning the implementation of an industrial fire brigade program; and a teaching outline consisting of eleven sections: (1)…
ERIC Educational Resources Information Center
Kerkhoff, Todd
2009-01-01
School fire drills are quickly becoming insignificant and inconvenient to school administrators. When the time for the monthly fire drill rolls around, it is often performed with a "let's get this over with" attitude. Although all schools conduct fire drills, seldom do they effectively train students and staff members how to respond in a real…
Sowmya, S V; Somashekar, R K
2010-11-01
Fire is the most spectacular natural disturbance that affects the forest ecosystem composition and diversity. Fire has a devastating effect on the landscape and its impact is felt at every level of the ecosystem and it is possible to map forest fire risk zone and thereby minimize the frequency of fire. There is a need for supranational approaches that analyze wide scenarios of factors involved and global fire effects. Fires can be monitored and analyzed over large areas in a timely and cost effective manner by using satellite imagery. Also Geographical Information System (GIS) can be used effectively to demarcate the fire risk zone map. Bhadra wildlife Sanctuary located in Kamataka, India was selected for this study. Vegetation, slope, distance from roads, settlements parameters were derived for a study area using topographic maps and field information. The Remote Sensing (RS) and Geographical Information System (GIS)-based forest fire risk model of the study area appeared to be highly compatible with the actual fire-affected sites. The temporal satellite data from 1989 to2006 have been analyzed to map the burnt areas. These classes were weighted according to their influence on forest fire. Four categories of fire risk regions such as Low, Moderate, High and Very high fire intensity zones were identified. It is predicted that around 10.31% of the area falls undermoderate risk zone.
Engineering and Development Program Plan, Aircraft Cabin Fire Safety.
1980-06-01
relative to a postcrash fuel fire, or whether advanced materials provide a significant safety benefit in comparison to inservice materials. if either...have always been controlled by early detection and prompt extinguishment action by effectively trained crew members. In addition, the fire resistant...occupants. g. Develop a computer fire test data bank with broad user availability for inservice and candidate cabin interior materials. h. Identify
Culture of fire and environmental education in wildfire-prone areas: current situation in Spain
Clara Quesada-Fernández; Daniel Quesada-Fernández
2013-01-01
The culture of fire in the context of climate change has become a complicated relationship between people and natural areas. The interaction between people and fire is not a new issue. The use of fire by humans in most aspects of life, especially in rural areas, together with rapid and haphazard growth of structures in wildfire-prone areas, has led...
Fire history and pattern in a Cascade Range landscape.
Peter H. Morrison; Frederick J. Swanson
1990-01-01
Fire history from years 1150 to 1985 was reconstructed by analyzing forest stands in two 1940-hectare areas in the central-western Cascade Range of Oregon. Serving as records for major fire episodes, these stands revealed a highly variable fire regime. The steeper, more dissected, lower elevation Cook-Quentin study area experienced more frequent fires (natural fire...
NASA Astrophysics Data System (ADS)
Bedia, J.; Herrera, S.; Gutiérrez, J. M.
2013-09-01
We develop fire occurrence and burned area models in peninsular Spain, an area of high variability in climate and fuel types, for the period 1990-2008. We based the analysis on a phytoclimatic classification aiming to the stratification of the territory into homogeneous units in terms of climatic and fuel type characteristics, allowing to test model performance under different climatic and fuel conditions. We used generalized linear models (GLM) and multivariate adaptive regression splines (MARS) as modelling algorithms and temperature, relative humidity, precipitation and wind speed, taken from the ERA-Interim reanalysis, as well as the components of the Canadian Forest Fire Weather Index (FWI) System as predictors. We also computed the standardized precipitation-evapotranspiration index (SPEI) as an additional predictor for the models of burned area. We found two contrasting fire regimes in terms of area burned and number of fires: one characterized by a bimodal annual pattern, characterizing the Nemoral and Oro-boreal phytoclimatic types, and another one exhibiting an unimodal annual cycle, with the fire season concentrated in the summer months in the Mediterranean and Arid regions. The fire occurrence models attained good skill in most of the phytoclimatic zones considered, yielding in some zones notably high correlation coefficients between the observed and modelled inter-annual fire frequencies. Total area burned also exhibited a high dependence on the meteorological drivers, although their ability to reproduce the observed annual burned area time series was poor in most cases. We identified temperature and some FWI system components as the most important explanatory variables, and also SPEI in some of the burned area models, highlighting the adequacy of the FWI system for fire modelling applications and leaving the door opened to the development a more complex modelling framework based on these predictors. Furthermore, we demonstrate the potential usefulness of ERA-Interim reanalysis data for the reconstruction of historical fire-climate relationships at the scale of analysis. Fire frequency predictions may provide a preferable basis for past fire history reconstruction, long-term monitoring and the assessment of future climate impacts on fire regimes across regions, posing several advantages over burned area as response variable.
NASA Astrophysics Data System (ADS)
Jin, Yufang; Goulden, Michael L.; Faivre, Nicolas; Veraverbeke, Sander; Sun, Fengpeng; Hall, Alex; Hand, Michael S.; Hook, Simon; Randerson, James T.
2015-09-01
The area burned by Southern California wildfires has increased in recent decades, with implications for human health, infrastructure, and ecosystem management. Meteorology and fuel structure are universally recognized controllers of wildfire, but their relative importance, and hence the efficacy of abatement and suppression efforts, remains controversial. Southern California’s wildfires can be partitioned by meteorology: fires typically occur either during Santa Ana winds (SA fires) in October through April, or warm and dry periods in June through September (non-SA fires). Previous work has not quantitatively distinguished between these fire regimes when assessing economic impacts or climate change influence. Here we separate five decades of fire perimeters into those coinciding with and without SA winds. The two fire types contributed almost equally to burned area, yet SA fires were responsible for 80% of cumulative 1990-2009 economic losses (3.1 Billion). The damage disparity was driven by fire characteristics: SA fires spread three times faster, occurred closer to urban areas, and burned into areas with greater housing values. Non-SA fires were comparatively more sensitive to age-dependent fuels, often occurred in higher elevation forests, lasted for extended periods, and accounted for 70% of total suppression costs. An improved distinction of fire type has implications for future projections and management. The area burned in non-SA fires is projected to increase 77% (±43%) by the mid-21st century with warmer and drier summers, and the SA area burned is projected to increase 64% (±76%), underscoring the need to evaluate the allocation and effectiveness of suppression investments.
GIS applied to location of fires detection towers in domain area of tropical forest.
Eugenio, Fernando Coelho; Rosa Dos Santos, Alexandre; Fiedler, Nilton Cesar; Ribeiro, Guido Assunção; da Silva, Aderbal Gomes; Juvanhol, Ronie Silva; Schettino, Vitor Roberto; Marcatti, Gustavo Eduardo; Domingues, Getúlio Fonseca; Alves Dos Santos, Gleissy Mary Amaral Dino; Pezzopane, José Eduardo Macedo; Pedra, Beatriz Duguy; Banhos, Aureo; Martins, Lima Deleon
2016-08-15
In most countries, the loss of biodiversity caused by the fires is worrying. In this sense, the fires detection towers are crucial for rapid identification of fire outbreaks and can also be used in environmental inspection, biodiversity monitoring, telecommunications mechanisms, telemetry and others. Currently the methodologies for allocating fire detection towers over large areas are numerous, complex and non-standardized by government supervisory agencies. Therefore, this study proposes and evaluates different methodologies to best location of points to install fire detection towers considering the topography, risk areas, conservation units and heat spots. Were used Geographic Information Systems (GIS) techniques and unaligned stratified systematic sampling for implementing and evaluating 9 methods for allocating fire detection towers. Among the methods evaluated, the C3 method was chosen, represented by 140 fire detection towers, with coverage of: a) 67% of the study area, b) 73.97% of the areas with high risk, c) 70.41% of the areas with very high risk, d) 70.42% of the conservation units and e) 84.95% of the heat spots in 2014. The proposed methodology can be adapted to areas of other countries. Copyright © 2016 Elsevier B.V. All rights reserved.
Using Natural Cementation Systems to Control Corrosion Dust on Un-surfaced Roads
2010-02-01
metallurgical slags ), volcanic glass , fly ash and low-fired clays • Can use waste alkali from manufacturing operations • No Portland cement is involved Soil...solidified with alkali- activated glass slag US Army Corps of Engineers 4 Pohakuloa Training Area (PTA) as a Test Site • Serious dust problem at site...Conventional Cement? • Glass can be both the aggregate and form the cementing phase • Waste glass ( slag , fly ash) can be used • More alkaline solution is
2008-06-01
complex, formally known as the Birch Creek Shist. Figure 3-3 – Proposed Donnelly Ridge Tower Site 3.1.4 Soils 3.1.4.1 The Delta Creek channel...in elevation, and fire history. Major vegetation types include white and black spruce coniferous forests; paper birch and poplar broadleaf forests...consists primarily of black spruce, dwarf birch , willow, sedges, and grasses (Figure 3-4). 3.2.2 Wildlife 3.2.2.1 The lands associated
1997-02-01
Winter, 1987, p. 64-71. Bartha , R., 1986, Biotechnology of petroleum pollutant biodegradation: Microbial Ecology , vol. 12, p. 155-172. Bauman, B., 1991...Prepared for Air Force Systems Command, Wright-Patterson Air Force Base, Ohio, June. Atlas , R.M., 1981, Microbial degradation of petroleum hydrocarbons...of jet fuel and gasoline, including the BTEX compounds (e.g., lamison et at., 1975; Atlas , 1981, 1984, 1988; Gibson and Subramanian, 1984; Reinhard et
1997-01-01
Command, Wright-Patterson Air Force Base, Ohio, June. Atlas , R.M., 1981, Microbial degradation of petroleum hydrocarbons - an environmental perspective...fuel and gasoline, including the BTEX compounds (e.g., Jamison et al, 1975; Atlas , 1981 1984, 1988; Gibson and Subramanian, 1984; Reinhard et al, 1984...Young, 1984; Bartha , 1986; Wilson et al, 1986, 1987, and 1990; Barker et al, 1987; Baedecker et al, 1988; Lee, 1988; Chiang et al, 1989; Grbic-Galic
A Near Term Approach to Embedded Training: Battle Command Visualization 101
2006-05-01
Example of Task Guidance area at the end of Module 1, Exercise 1 (Level 1) ...... 26 Figure 9 Example of Robo -Scout information, accessed through the...unmanned ground vehicle (UGV) sensor, the Robo -Scout. They will be equipped with both passive and active systems to provide target acquisition, real...PIR# Track of Update RqieTemplated Required 1 Tracked & NAI 1, 2 S, T S200 synthetic L 2 hrs Vehicle type, Intel, Fires (PIR 1) Wheeled aperture radar
Mitani, Satoko; Fujita, Masatoshi; Sakamoto, Satoko; Shirakawa, Taro
2006-05-01
We investigated the effect of autogenic training (AT) on cardiac autonomic nervous activity in fire services workers with the use of the questionnaire of the Japanese-language version of Impact of Event Scale-Revised (IES-R-J) and indexes of heart rate variability. We studied 22 male fire services workers who were divided into posttraumatic stress disorder (PTSD)-related stress group (n=10) and control group (n=12). They underwent AT twice or three times a week for 2 months. Posttraumatic stress disorder-related stress group showed a significantly higher cardiac sympathetic nervous activity and a significantly lower cardiac parasympathetic nervous activity than control group at baseline. Autogenic training significantly decreased cardiac sympathetic nervous activity and significantly increased cardiac parasympathetic nervous activity in both groups. These changes were accompanied by a significant decrease in the total points of IES-R-J. Autogenic training is effective for ameliorating the disturbance of cardiac autonomic nervous activity and psychological issues secondary to PTSD.
Dynamics and Physiological Roles of Stochastic Firing Patterns Near Bifurcation Points
NASA Astrophysics Data System (ADS)
Jia, Bing; Gu, Huaguang
2017-06-01
Different stochastic neural firing patterns or rhythms that appeared near polarization or depolarization resting states were observed in biological experiments on three nervous systems, and closely matched those simulated near bifurcation points between stable equilibrium point and limit cycle in a theoretical model with noise. The distinct dynamics of spike trains and interspike interval histogram (ISIH) of these stochastic rhythms were identified and found to build a relationship to the coexisting behaviors or fixed firing frequency of four different types of bifurcations. Furthermore, noise evokes coherence resonances near bifurcation points and plays important roles in enhancing information. The stochastic rhythms corresponding to Hopf bifurcation points with fixed firing frequency exhibited stronger coherence degree and a sharper peak in the power spectrum of the spike trains than those corresponding to saddle-node bifurcation points without fixed firing frequency. Moreover, the stochastic firing patterns changed to a depolarization resting state as the extracellular potassium concentration increased for the injured nerve fiber related to pathological pain or static blood pressure level increased for aortic depressor nerve fiber, and firing frequency decreased, which were different from the physiological viewpoint that firing frequency increased with increasing pressure level or potassium concentration. This shows that rhythms or firing patterns can reflect pressure or ion concentration information related to pathological pain information. Our results present the dynamics of stochastic firing patterns near bifurcation points, which are helpful for the identification of both dynamics and physiological roles of complex neural firing patterns or rhythms, and the roles of noise.
Fire tolerance of a resprouting Artemisia (Asteraceae) shrub
Winter, S.L.; Fuhlendorf, S.D.; Goad, C.L.; Davis, C.A.; Hickman, K.R.; Leslie, David M.
2011-01-01
In North America, most Artemisia (Asteraceae) shrub species lack the ability to resprout after disturbances that remove aboveground biomass. We studied the response of one of the few resprouting Artemisia shrubs, Artemisia filifolia (sand sagebrush), to the effects of prescribed fires. We collected data on A. filifolia density and structural characteristics (height, canopy area, and canopy volume) in an A. filifolia shrubland in the southern Great Plains of North America. Our study sites included areas that had not been treated with prescribed fire, areas that had been treated with only one prescribed fire within the previous 5 years, and areas that had been treated with two prescribed fires within the previous 10 years. Our data were collected at time periods ranging from 1/2 to 5 years after the prescribed fires. Density of A. filifolia was not affected by one or two fires. Structural characteristics, although initially altered by prescribed fire, recovered to levels characteristic of unburned areas in 3-4 years after those fires. In contrast to most non-sprouting North American Artemisia shrub species, our research suggested that the resprouting A. filifolia is highly tolerant to the effects of fire. ?? 2011 Springer Science+Business Media B.V.
Sean A. Parks; Carol Miller; Cara R. Nelson; Zachary A. Holden
2014-01-01
Wildland fire is an important natural process in many ecosystems. However, fire exclusion has reduced frequency of fire and area burned in many dry forest types, which may affect vegetation structure and composition, and potential fire behavior. In forests of the western U.S., these effects pose a challenge for fire and land managers who seek to restore the ecological...
NASA Astrophysics Data System (ADS)
Jiménez-Ruano, Adrián; Rodrigues Mimbrero, Marcos; de la Riva Fernández, Juan
2017-04-01
Understanding fire regime is a crucial step towards achieving a better knowledge of the wildfire phenomenon. This study proposes a method for the analysis of fire regime based on multidimensional scatterplots (MDS). MDS are a visual approach that allows direct comparison among several variables and fire regime features so that we are able to unravel spatial patterns and relationships within the region of analysis. Our analysis is conducted in Spain, one of the most fire-affected areas within the Mediterranean region. Specifically, the Spanish territory has been split into three regions - Northwest, Hinterland and Mediterranean - considered as representative fire regime zones according to MAGRAMA (Spanish Ministry of Agriculture, Environment and Food). The main goal is to identify key relationships between fire frequency and burnt area, two of the most common fire regime features, with socioeconomic activity and climate. In this way we will be able to better characterize fire activity within each fire region. Fire data along the period 1974-2010 was retrieved from the General Statistics Forest Fires database (EGIF). Specifically, fire frequency and burnt area size was examined for each region and fire season (summer and winter). Socioeconomic activity was defined in terms of human pressure on wildlands, i.e. the presence and intensity of anthropogenic activity near wildland or forest areas. Human pressure was built from GIS spatial information about land use (wildland-agriculture and wildland-urban interface) and demographic potential. Climate variables (average maximum temperature and annual precipitation) were extracted from MOTEDAS (Monthly Temperature Dataset of Spain) and MOPREDAS (Monthly Precipitation Dataset of Spain) datasets and later reclassified into ten categories. All these data were resampled to fit the 10x10 Km grid used as spatial reference for fire data. Climate and socioeconomic variables were then explored by means of MDS to find the extent to which fire frequency and burnt areas are controlled by either environmental, human, or both factors. Results reveal a noticeable link between fire frequency and human activity, especially in the Northwest area during winter. On the other hand, in the Hinterland and Mediterranean regions, human and climate factors 'work' together in terms of their relationship with fire activity, being the concurrence of high human pressure and favourable climate conditions the main driver. In turn, burned area shows a similar behaviour except in the Hinterland region, were fire-affected area depends mostly on climate factors. Overall, we can conclude that the visual analysis of multidimensional scatterplots has proved to be a powerful tool that facilitates characterization and investigation of fire regimes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaul, G.; Nakhamkin, M.; Swensen, E.
1994-12-01
Turbomachinery trains were conceptually developed for three power plant concepts: Compressed Air Storage with Humidification and Integrated Gasification and Natural Gas Firing (CASHING), Natural Gas fired Compressed Air Storage with Humidification (NGCASH), and Integrated Gasification fired Compressed Air Storage with Humidification (IGCASH). Performance data, arrangement drawings, cost estimates, and other technical information for the three turboexpander trains were developed based on the Westinghouse BB51 steam turbine for the high pressure expander and the expander section of the W501F or W501D5 combustion turbine for the low pressure expander. The study supports previous EPRI projects investigating the performance and cost of CASHING,more » NGCASH, and IGCASH concepts and provides a basis for quotations that can be used in evaluating compressed air energy storage concepts in future projects.« less
The impact of a 2 X CO2 climate on lightning-caused fires
NASA Technical Reports Server (NTRS)
Price, Colin; Rind, David
1994-01-01
Future climate change could have significant repercussions for lightning-caused wildfires. Two empirical fire models are presented relating the frequency of lightning fires and the area burned by these fires to the effective precipitation and the frequency of thunderstorm activity. One model deals with the seasonal variations in lightning fires, while the second model deals with the interannual variations of lightning fires. These fire models are then used with the Goddard Institute for Space Studies General Circulation Model to investigate possible changes in fire frequency and area burned in a 2 X CO2 climate. In the United States, the annual mean number of lightning fires increases by 44%, while the area burned increases by 78%. On a global scale, the largest increase in lightning fires can be expected in untouched tropical ecosystems where few natural fires occur today.
The impact of antecedent fire area on burned area in southern California coastal ecosystems
Price, Owen F.; Bradstock, Ross A.; Keeley, Jon E.; Syphard, Alexandra D.
2012-01-01
Frequent wildfire disasters in southern California highlight the need for risk reduction strategies for the region, of which fuel reduction via prescribed burning is one option. However, there is no consensus about the effectiveness of prescribed fire in reducing the area of wildfire. Here, we use 29 years of historical fire mapping to quantify the relationship between annual wildfire area and antecedent fire area in predominantly shrub and grassland fuels in seven southern California counties, controlling for annual variation in weather patterns. This method has been used elsewhere to measure leverage: the reduction in wildfire area resulting from one unit of prescribed fire treatment. We found little evidence for a leverage effect (leverage = zero). Specifically our results showed no evidence that wildfire area was negatively influenced by previous fires, and only weak relationships with weather variables rainfall and Santa Ana wind occurrences, which were variables included to control for inter-annual variation. We conclude that this is because only 2% of the vegetation burns each year and so wildfires rarely encounter burned patches and chaparral shrublands can carry a fire within 1 or 2 years after previous fire. Prescribed burning is unlikely to have much influence on fire regimes in this area, though targeted treatment at the urban interface may be effective at providing defensible space for protecting assets. These results fit an emerging global model of fire leverage which position California at the bottom end of a continuum, with tropical savannas at the top (leverage = 1: direct replacement of wildfire by prescribed fire) and Australian eucalypt forests in the middle (leverage ∼ 0.25).
The impact of antecedent fire area on burned area in southern California coastal ecosystems.
Price, Owen F; Bradstock, Ross A; Keeley, Jon E; Syphard, Alexandra D
2012-12-30
Frequent wildfire disasters in southern California highlight the need for risk reduction strategies for the region, of which fuel reduction via prescribed burning is one option. However, there is no consensus about the effectiveness of prescribed fire in reducing the area of wildfire. Here, we use 29 years of historical fire mapping to quantify the relationship between annual wildfire area and antecedent fire area in predominantly shrub and grassland fuels in seven southern California counties, controlling for annual variation in weather patterns. This method has been used elsewhere to measure leverage: the reduction in wildfire area resulting from one unit of prescribed fire treatment. We found little evidence for a leverage effect (leverage = zero). Specifically our results showed no evidence that wildfire area was negatively influenced by previous fires, and only weak relationships with weather variables rainfall and Santa Ana wind occurrences, which were variables included to control for inter-annual variation. We conclude that this is because only 2% of the vegetation burns each year and so wildfires rarely encounter burned patches and chaparral shrublands can carry a fire within 1 or 2 years after previous fire. Prescribed burning is unlikely to have much influence on fire regimes in this area, though targeted treatment at the urban interface may be effective at providing defensible space for protecting assets. These results fit an emerging global model of fire leverage which position California at the bottom end of a continuum, with tropical savannas at the top (leverage = 1: direct replacement of wildfire by prescribed fire) and Australian eucalypt forests in the middle (leverage ~ 0.25). Copyright © 2012 Elsevier Ltd. All rights reserved.
Fire-climate interactions in the Selway-Bitterroot Wilderness area
Kurt F. Kipfmueller; Thomas W. Swetnam
2000-01-01
Tree-ring reconstructed summer drought was examined in relation to the occurrence of 15 fires in the Selway-Bitterroot Wilderness Area (SBW). The ten largest fire years between 1880 and 1995 were selected from historical fire atlas data; five additional fire years were selected from a fire history completed in a subalpine forest within the SBW. Results of the analysis...
Waste Technology Engineering Laboratory (324 building)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kammenzind, D.E.
The 324 Facility Standards/Requirements Identification Document (S/RID) is comprised of twenty functional areas. Two of the twenty functional areas (Decontamination and Decommissioning and Environmental Restoration) were determined as nonapplicable functional areas and one functional area (Research and Development and Experimental Activities) was determined applicable, however, requirements are found in other functional areas and will not be duplicated. Each functional area follows as a separate chapter, either containing the S/RID or a justification for nonapplicability. The twenty functional areas listed below follow as chapters: 1. Management Systems; 2. Quality Assurance; 3. Configuration Management; 4. Training and Qualification; 5. Emergency Management; 6.more » Safeguards and Security; 7. Engineering Program; 8. Construction; 9. Operations; 10. Maintenance; 11. Radiation Protection; 12. Fire Protection; 13. Packaging and Transportation; 14. Environmental Restoration; 15. Decontamination and Decommissioning; 16. Waste Management; 17. Research and Development and Experimental Activities; 18. Nuclear Safety; 19. Occupational Safety and Health; 20. Environmental Protection.« less
Estimation of the Forest Fire Risk in Indonesia based on Satellite Remote Sensing
NASA Astrophysics Data System (ADS)
Suzuki, H.; Takahashi, Y.; Hashimoto, A.; Akita, M.; Hasegawa, Y.; Ogino, Y.; Naruse, N.; Takahashi, Y.
2016-12-01
To minimize forest fires in tropical area is extremely important, because the fire has a large impact on global warming, biodiversity, and human society. In the previous study, Shimada and Ishibashi monitored the ground-water lever from the value of Normalized Difference Vegetation Index (NDVI) obtained in Kalimantan Island to predict where the forest fires will happen. We have developed a method to map the forest fire risk by calculating the value of Modified Soil Adjusted Vegetation Index 2 (MSAVI2). Moreover, we investigated the relation between the distance from a road as an artificial factor and the occurrence of the fire.First, calculating the MSAVI2 from Landsat 7 and 8 images of August, 2015 around Martapura in South Sumatra, Indonesia, we mapped the area where the plants were stressed. Next, we checked the degrees of matching between the area of low MSAVI2 and the forest fire points.As a result, half of the fires happened in the area having the MSAVI2 values of 0.20 to 0.35. When we focused on only the area which is over 5 kilometers far from a road, the degrees of matching became higher; it rose up to 62 percent.Those results indicate that the fire risks relate to the dry area calculated as low MSAVI2 in the case with less human activities. We need to consider an effect of artificial factors to estimate the whole risk of forest fire.In conclusion, the map of forest fire risk by calculating the value of MSAVI2 is applicable to an area with less artificial factor, while we have to take the effect of artificial fire factor into the consideration.
NASA Astrophysics Data System (ADS)
Semenova, O. M.; Lebedeva, L. S.; Nesterova, N. V.; Vinogradova, T. A.
2015-06-01
Twelve mountainous basins of the Vitim Plateau (Eastern Siberia, Russia) with areas ranging from 967 to 18 200 km2 affected by extensive fires in 2003 (from 13 to 78% of burnt area) were delineated based on MODIS Burned Area Product. The studied area is characterized by scarcity of hydrometeorological observations and complex hydrological processes. Combined analysis of monthly series of flow and precipitation was conducted to detect short-term fire impact on hydrological response of the basins. The idea of basin-analogues which have significant correlation of flow with "burnt" watersheds in stationary (pre-fire) period with the assumption that fire impact produced an outlier of established dependence was applied. Available data allowed for qualitative detection of fire-induced changes at two basins from twelve studied. Summer flow at the Amalat and Vitimkan Rivers (22 and 78% proportion of burnt area in 2003, respectively) increased by 40-50% following the fire.The impact of fire on flow from the other basins was not detectable.The hydrological model Hydrograph was applied to simulate runoff formation processes for stationary pre-fire and non-stationary post-fire conditions. It was assumed that landscape properties changed after the fire suggest a flow increase. These changes were used to assess the model parameters which allowed for better model performance in the post-fire period.
Timothy Ingalsbee
2001-01-01
Since 1992 a collaborative group of fire scientists, forest conservationists, and Federal resource specialists have been developing proposals for a Research Natural Area (RNA) in the Warner Creek Fire area on the Willamette National Forest in Oregon. Inspired by these proposals, the Oregon Natural Heritage Plan created the new category of "Fire Process RNAs"...
NASA Astrophysics Data System (ADS)
Reddy, C. Sudhakar; Padma Alekhya, V. V. L.; Saranya, K. R. L.; Athira, K.; Jha, C. S.; Diwakar, P. G.; Dadhwal, V. K.
2017-02-01
Carbon emissions released from forest fires have been identified as an environmental issue in the context of global warming. This study provides data on spatial and temporal patterns of fire incidences, burnt area and carbon emissions covering natural vegetation types (forest, scrub and grassland) and Protected Areas of India. The total area affected by fire in the forest, scrub and grasslands have been estimated as 48765.45, 6540.97 and 1821.33 km 2, respectively, in 2014 using Resourcesat-2 AWiFS data. The total CO 2 emissions from fires of these vegetation types in India were estimated to be 98.11 Tg during 2014. The highest emissions were caused by dry deciduous forests, followed by moist deciduous forests. The fire season typically occurs in February, March, April and May in different parts of India. Monthly CO 2 emissions from fires for different vegetation types have been calculated for February, March, April and May and estimated as 2.26, 33.53, 32.15 and 30.17 Tg, respectively. Protected Areas represent 11.46% of the total natural vegetation cover of India. Analysis of fire occurrences over a 10-year period with two types of sensor data, i.e., AWiFS and MODIS, have found fires in 281 (out of 614) Protected Areas of India. About 16.78 Tg of CO 2 emissions were estimated in Protected Areas in 2014. The natural vegetation types of Protected Areas have contributed for burnt area of 17.3% and CO 2 emissions of 17.1% as compared to total natural vegetation burnt area and emissions in India in 2014. 9.4% of the total vegetation in the Protected Areas was burnt in 2014. Our results suggest that Protected Areas have to be considered for strict fire management as an effective strategy for mitigating climate change and biodiversity conservation.
James L. Murphy; Frank T. Cole
1987-01-01
The Fish and Wildlife Service, U.S. Department of the Interior, uses prescribed fire for habitat improvement on over 400 National Wildlife Refuges across the United States. Wildfire is a problem on some refuges. Escaped fires have resulted in fatalities and the loss of millions of dollars in natural and man-made resources. The Service recognized the critical need for...
Assessing landscape scale wildfire exposure for highly valued resources in a Mediterranean area.
Alcasena, Fermín J; Salis, Michele; Ager, Alan A; Arca, Bachisio; Molina, Domingo; Spano, Donatella
2015-05-01
We used a fire simulation modeling approach to assess landscape scale wildfire exposure for highly valued resources and assets (HVR) on a fire-prone area of 680 km(2) located in central Sardinia, Italy. The study area was affected by several wildfires in the last half century: some large and intense fire events threatened wildland urban interfaces as well as other socioeconomic and cultural values. Historical wildfire and weather data were used to inform wildfire simulations, which were based on the minimum travel time algorithm as implemented in FlamMap. We simulated 90,000 fires that replicated recent large fire events in the area spreading under severe weather conditions to generate detailed maps of wildfire likelihood and intensity. Then, we linked fire modeling outputs to a geospatial risk assessment framework focusing on buffer areas around HVR. The results highlighted a large variation in burn probability and fire intensity in the vicinity of HVRs, and allowed us to identify the areas most exposed to wildfires and thus to a higher potential damage. Fire intensity in the HVR buffers was mainly related to fuel types, while wind direction, topographic features, and historically based ignition pattern were the key factors affecting fire likelihood. The methodology presented in this work can have numerous applications, in the study area and elsewhere, particularly to address and inform fire risk management, landscape planning and people safety on the vicinity of HVRs.
A WSN-based tool for urban and industrial fire-fighting.
De San Bernabe Clemente, Alberto; Martínez-de Dios, José Ramiro; Ollero Baturone, Aníbal
2012-11-06
This paper describes a WSN tool to increase safety in urban and industrial fire-fighting activities. Unlike most approaches, we assume that there is no preexisting WSN in the building, which involves interesting advantages but imposes some constraints. The system integrates the following functionalities: fire monitoring, firefighter monitoring and dynamic escape path guiding. It also includes a robust localization method that employs RSSI-range models dynamically trained to cope with the peculiarities of the environment. The training and application stages of the method are applied simultaneously, resulting in significant adaptability. Besides simulations and laboratory tests, a prototype of the proposed system has been validated in close-to-operational conditions.
NASA Astrophysics Data System (ADS)
Filizzola, Carolina; Belloni, Antonella; Benigno, Giuseppe; Biancardi, Alberto; Corrado, Rosita; Coviello, Irina; De Costanzo, Giovanni; Genzano, Nicola; Lacava, Teodosio; Lisi, Mariano; Marchese, Francesco; Mazzeo, Giuseppe; Merzagora, Cinzio; Paciello, Rossana; Pergola, Nicola; Sannazzaro, Filomena; Serio, Salvatore; Tramutoli, Valerio
2013-04-01
Every year, hundreds of thousands of hectares of European forests are destroyed by fires. Due to the particular topography, landscape and demographic distribution in Europe (very different from typical scenarios of China, USA, Canada and Australia), rapidity in fire sighting is still the determining factor in limiting damages to people and goods. Moreover, the possibility of early fire detection means also potentially to reduce the size of the event to be faced, the necessary fire fighting resources and, therefore, even the reaction times. In such a context, integration of satellite technologies (mainly high temporal resolution data) and traditional surveillance systems within the fire fighting procedures seems to positively impact on the effectiveness of active fire fighting as demonstrated by recent experiences over Italian territory jointly performed by University of Basilicata, IMAA-CNR and Local Authorities. Real time implementation was performed since 2007, during fire seasons, over several Italian regions with different fire regimes and features, in order to assess the actual potential of different satellite-based fire detection products to support regional and local authorities in efficiently fighting fires and better mitigating their negative effects. Real-time campaigns were carried out in strict collaboration with end-users within the framework of specific projects (i.e. the AVVISA, AVVISTA and AVVISA-Basilicata projects) funded by Civil Protection offices of Regione Lombardia, Provincia Regionale di Palermo and Regione Basilicata in charge of fire risk management and mitigation. A tailored training program was dedicated to the personnel of Regional Civil Protection offices in order to ensure the full understanding and the better integration of satellite based products and tools within the existing fire fighting protocols. In this work, outcomes of these practices are shown and discussed, especially highlighting the impact that a real time satellite system may have in assisting and complementing traditional surveillance systems to mitigate damages due to fires. In particular, the usefulness of satellite technology in an operational context was demonstrated mainly in reference to: i) the possibility of identifying fires at an early stage (so avoiding that small hotbeds could extend and become dangerous for citizens and destructive for environmental protected areas) as well as ii) the possibility to have an effective territorial control (e.g. discovering illegal burning fires such as unauthorized cleaning fires, and permitting local authorities to rapidly intervene and catch red-handed pyromaniacs).
Catastrophic Fires in Russian Forests
NASA Astrophysics Data System (ADS)
Sukhinin, A. I.; McRae, D. J.; Stocks, B. J.; Conard, S. G.; Hao, W.; Soja, A. J.; Cahoon, D.
2010-12-01
We evaluated the contribution of catastrophic fires to the total burned area and the amount of tree mortality in Russia since the 1970’s. Such fires occurred in the central regions of European Russia (1972, 1976, 1989, 2002, 2010), Khabarovsk krai (1976, 1988, 1998), Amur region (1997-2002), Republics of Yakutia and Tuva (2002), Magadan and Kamchatka oblast (1984, 2001, 2010), and Irkutsk, Chita, Amur regions, Buryat, Agin national districts (2003, 2007-08). We define a catastrophic fire as a single high-severity fire that covers more than 10,000 ha and results in total consumption of the litter and humus layers and in high tree mortality, or the simultaneous occurrence of several high-severity fires in a given region with a total area exceeding 10,000 km2. Fires on this scale can cause substantial economic, social and environmental effects, with regional to global impacts. We hypothesize that there is a positive feedback between anticyclone growth and energy release from wildfires burning over large areas. Usually the first blocking anticyclone appears in June in Russia, bringing with it dry weather that increases fire hazard. The anticyclonic pattern has maximum activity in the end of July and disappears around the middle of August. When high fire activity occurs, the anticyclone may strengthen and develop a blocking character that prevents cyclonic patterns from moving into anticyclone-dominated areas, where the fire danger index may be more than six times the average maximum. The likelihood of uncontrolled fire situations developing increases greatly when the fire number and burned area exceed critical values as a function of conditions that favor high intensity fires. In such situations fire suppression by regional forest protection services becomes impossible and federal resources are required. If the appearance of a blocking anticyclone is forecast, active fire prevention and suppression of small fires (most of which appear to be human caused) is critical. Based on NOAA and TOMS daily data, we estimated fire emissions (including CO2, CO, CH4 and other smoke aerosols) of over 70 Tg Carbon for Yakutian fires in 2002 and more than 120 Tg C for all Russian fires in 2010. We note the potential for increasing amounts of methane emissions when fires occur in permafrost zones and peat bogs. Post-fire changes in permafrost and vegetation cover are discussed in the connection changes in solar radiance balance. During the fire season of 2006 in the Eastern-Siberian, Transbaikal, and Far East regions we identified more than 15,000 fires with a total area of 120,000 km2. From 2002-2010 the annual number of fires in this area ranged from 10,000 to 16,500, and annual burned areas ranged from a low of 30 000 km2 in 2004 to a high of 145,000 km2 in 2003.
ERIC Educational Resources Information Center
Ruan, Lian J.
2011-01-01
Fire service field staff instructors seek and share information and use information sources during their instructional work of teaching, training and curriculum development. This study is the first attempt to study their information-seeking and sharing behaviors, which have not previously been investigated empirically. Twenty-five fire service…
Prescribed Fire Education at Oklahoma State University: Training Our Future Pyros
John R. Weir
2008-01-01
The Rangeland Ecology and Management program at Oklahoma State University recognized the need for a practical, hands-on course designed for undergraduate and graduate students, with instruction on conducting prescribed fires for vegetation management, wildlife management, and livestock management. Two separate prescribed fire courses were initiated in the spring of...
Guidelines for Fire Service Education Programs in Community and Junior Colleges.
ERIC Educational Resources Information Center
Favreau, Donald F.
This report serves as a guideline for fire service education. For men filling the estimated 10,000 opportunities in career fire department organizations each year in the 1970s, it is necessary that they receive a supplement to department-level training in drills and skills. Knowledge of hydraulics, chemistry, mechanical engineering, law…
Guidance on spatial wildland fire analysis: models, tools, and techniques
Richard D. Stratton
2006-01-01
There is an increasing need for spatial wildland fire analysis in support of incident management, fuel treatment planning, wildland-urban assessment, and land management plan development. However, little guidance has been provided to the field in the form of training, support, or research examples. This paper provides guidance to fire managers, planners, specialists,...
Molly E. Hunter; Jose M. Iniguez; Calvin A. Farris
2014-01-01
Fire suppression has been the dominant fire management strategy in the West over the last century. However, managers of the Gila and Aldo Leopold Wilderness Complex in New Mexico and the Saguaro Wilderness Area in Arizona have allowed fire to play a more natural role for decades. This report summarizes the effects of these fire management practices on key resources,...
Mercury emission from coal seam fire at Wuda, Inner Mongolia, China
NASA Astrophysics Data System (ADS)
Liang, Yanci; Liang, Handong; Zhu, Shuquan
2014-02-01
The underground coal seam fire in the Wuda, Inner Mongolia of china is one of the most serious coal fires in the world with a history over 50 years and endangers the neighboring downwind urban area. To investigate the potential mercury emission and migration from the coal seam fire, in situ real-time measurement of total gaseous mercury (TGM) concentration using Lumex RA-915 + mercury analyzer were implemented on the fire zone and the urban area. The results show an average TGM concentration of 464 ng m-3 in the fumes released from surface vents and cracks on the fire zone, which leads to an elevated TGM concentration of 257 ng m-3 (211-375 ng m-3) in the near-surface air at the fire zone and 89 ng m-3 (23-211 ng m-3) at the peripheral area. The average TGM concentration in the adjoining downwind urban area of Wuda is 33 ng m-3. This result suggests that the coal seam fire may not only contribute to the global mercury inventory but also be a novel source for mercury pollution in the urban areas. The scenario of urban areas being adjacent to coal seam fires is not limited to Wuda but relatively common in northern China and elsewhere. Whether there are other cities under influence of coal seam fires merits further investigation.
Deave, Toity; Hawkins, Adrian; Kumar, Arun; Hayes, Mike; Cooper, Nicola; Watson, Michael; Ablewhite, Joanne; Coupland, Carol; Sutton, Alex; Majsak-Newman, Gosia; McDaid, Lisa; Goodenough, Trudy; Beckett, Kate; McColl, Elaine; Reading, Richard; Kendrick, Denise
2017-01-01
Background Many developed countries have high mortality rates for fire-related deaths in children aged 0–14 years with steep social gradients. Evidence-based interventions to promote fire safety practices exist, but the impact of implementing a range of these interventions in children’s services has not been assessed. We developed an Injury Prevention Briefing (IPB), which brought together evidence about effective fire safety interventions and good practice in delivering interventions; plus training and facilitation to support its use and evaluated its implementation. Methods We conducted a cluster randomised controlled trial, with integrated qualitative and cost-effectiveness nested studies, across four study sites in England involving children’s centres in disadvantaged areas; participants were staff and families attending those centres. Centres were stratified by study site and randomised within strata to one of three arms: IPB plus facilitation (IPB+), IPB only, usual care. IPB+ centres received initial training and facilitation at months 1, 3, and 8. Baseline data from children’s centres were collected between August 2011 and January 2012 and follow-up data were collected between June 2012 and June 2013. Parent baseline data were collected between January 2012 and May 2012 and follow-up data between May 2013 and September 2013. Data comprised baseline and 12 month parent- and staff-completed questionnaires, facilitation contact data, activity logs and staff interviews. The primary outcome was whether families had a plan for escaping from a house fire. Treatment arms were compared using multilevel models to account for clustering by children’s centre. Results 1112 parents at 36 children’s centres participated. There was no significant effect of the intervention on families’ possession of plans for escaping from a house fire (adjusted odds ratio (AOR) IPB only vs. usual care: 0.93, 95%CI 0.58, 1.49; AOR IPB+ vs. usual care 1.41, 95%CI 0.91, 2.20). However, significantly more families in the intervention arms reported more behaviours for escaping from house fires (AOR IPB only vs. usual care: 2.56, 95%CI 01.38, 4.76; AOR IPB+ vs. usual care 1.78, 95%CI 1.01, 3.15). Conclusion Our study demonstrated that children’s centres can deliver an injury prevention intervention to families in disadvantaged communities and achieve changes in home safety behaviours. PMID:28339460
Deave, Toity; Hawkins, Adrian; Kumar, Arun; Hayes, Mike; Cooper, Nicola; Watson, Michael; Ablewhite, Joanne; Coupland, Carol; Sutton, Alex; Majsak-Newman, Gosia; McDaid, Lisa; Goodenough, Trudy; Beckett, Kate; McColl, Elaine; Reading, Richard; Kendrick, Denise
2017-01-01
Many developed countries have high mortality rates for fire-related deaths in children aged 0-14 years with steep social gradients. Evidence-based interventions to promote fire safety practices exist, but the impact of implementing a range of these interventions in children's services has not been assessed. We developed an Injury Prevention Briefing (IPB), which brought together evidence about effective fire safety interventions and good practice in delivering interventions; plus training and facilitation to support its use and evaluated its implementation. We conducted a cluster randomised controlled trial, with integrated qualitative and cost-effectiveness nested studies, across four study sites in England involving children's centres in disadvantaged areas; participants were staff and families attending those centres. Centres were stratified by study site and randomised within strata to one of three arms: IPB plus facilitation (IPB+), IPB only, usual care. IPB+ centres received initial training and facilitation at months 1, 3, and 8. Baseline data from children's centres were collected between August 2011 and January 2012 and follow-up data were collected between June 2012 and June 2013. Parent baseline data were collected between January 2012 and May 2012 and follow-up data between May 2013 and September 2013. Data comprised baseline and 12 month parent- and staff-completed questionnaires, facilitation contact data, activity logs and staff interviews. The primary outcome was whether families had a plan for escaping from a house fire. Treatment arms were compared using multilevel models to account for clustering by children's centre. 1112 parents at 36 children's centres participated. There was no significant effect of the intervention on families' possession of plans for escaping from a house fire (adjusted odds ratio (AOR) IPB only vs. usual care: 0.93, 95%CI 0.58, 1.49; AOR IPB+ vs. usual care 1.41, 95%CI 0.91, 2.20). However, significantly more families in the intervention arms reported more behaviours for escaping from house fires (AOR IPB only vs. usual care: 2.56, 95%CI 01.38, 4.76; AOR IPB+ vs. usual care 1.78, 95%CI 1.01, 3.15). Our study demonstrated that children's centres can deliver an injury prevention intervention to families in disadvantaged communities and achieve changes in home safety behaviours.
Fire fighting and its influence on the body.
Rossi, René
2003-08-15
Working conditions for fire fighters can be described according to the environment temperature and the incident radiant heat flux. Measurements for this study in buildings for fire fighting training have shown that fire fighters are typically exposed to radiant heat fluxes of between 5 and 10 kWm(-2) during this kind of exercise. The heat load can nevertheless be much higher. In one case, 42 kWm(-2) was measured. The temperatures reached between 100 and 190 degrees C at 1 m above ground, going up to 278 degrees C in one case. Human trials have been performed with 17 fire fighters. After exercises (about 15 min) in a heated room, the mean core temperature of the fire fighters rose by 0.6 degrees C with a surrounding temperature of 31 degrees C and 1.0 degrees C with 38 degrees C. The sweat production varied from 0.7 to 2.1 lh(-1); 16% to 45% of sweat remained in the clothing layers. During the exercises in the training buildings, a mean of 48 degrees C has been measured between fire fighters' clothing and workwear. These conditions lead to an increase of the relative humidity in all the jackets up to 100%. When the fire fighters came out of the fire, the humidity remained at this level in the PVC coated jackets while it was in some cases strongly reduced in breathable jackets.
ALLTEM Multi-Axis Electromagnetic Induction System Demonstration and Validation
2011-11-17
fencing that test the capabilities of the platform systems Recently the Open Field area was reconfigured to emulate typical impact area conditions. The...surveyed. • Open field (indirect fire) The indirect fire subarea contains only three munition types that could be typically found at an impact area...direct fire subarea contains only three munition types that could be typically found at an impact area of a direct fire weapons range. These are 25 mm
Allen, J.C.; Krieger, S.M.; Walters, J.R.; Collazo, J.A.
2006-01-01
We determined the effects of fire history and a riparian-upland gradient on the breeding bird community at Fort Bragg Military Installation in North Carolina, one of the largest remnant areas of the endangered longleaf pine (Pinus palustris) ecosystem. Study sites were classified into two treatments: fire-intense (areas experiencing growing-season burns) and fire-suppressed (areas lacking fires). Within each treatment, bird and vegetation data were recorded at point-count stations positioned at three distances from streamhead pocosins to characterize the riparian-upland habitat gradient: 0, 75, and ≥150 m. Total bird abundance and species richness varied significantly along the riparian-upland gradient, with pocosins contributing greatly to avian biodiversity. Our data revealed strong effects of fire history and riparian-upland gradient on bird species, which we described in terms of breeding-bird assemblages. Members of the open longleaf assemblage (e.g., Red- cockaded Woodpecker [Picoides borealis], Bachman's Sparrow [Aimophila aestivalis]) were most common in fire-intense areas and at upland locations. Members of the fire-suppressed assemblage (e.g., Wood Thrush [Hylocichla mustelina], Ovenbird [Seiurus aurocapilla]) were confined to pocosins in fire-intense areas, but became more abundant in fire-suppressed areas. Members of the pocosin assemblage (e.g., Eastern Towhee [Pipilo erythropthalamus], Common Yellowthroat [Geothlypis trichas]) were largely confined to pocosins and, in some cases, were most abundant in fire-intense pocosins. Fire suppression increased structural diversity of vegetation and promoted one breeding-bird assemblage (fire-suppressed), but at the expense of two others (open longleaf, pocosin). Continued management of Fort Bragg to promote longleaf pine restoration is essential for supporting conservation of the open-longleaf bird assemblage; in addition, it will benefit the pocosin assemblage.
Parks, Sean A; Holsinger, Lisa M; Miller, Carol; Nelson, Cara R
2015-09-01
Theory suggests that natural fire regimes can result in landscapes that are both self-regulating and resilient to fire. For example, because fires consume fuel, they may create barriers to the spread of future fires, thereby regulating fire size. Top-down controls such as weather, however, can weaken this effect. While empirical examples demonstrating this pattern-process feedback between vegetation and fire exist, they have been geographically limited or did not consider the influence of time between fires and weather. The availability of remotely sensed data identifying fire activity over the last four decades provides an opportunity to explicitly quantify-the ability of wildland fire to limit the progression of subsequent fire. Furthermore, advances in fire progression mapping now allow an evaluation of how daily weather as a top-down control modifies this effect. In this study, we evaluated the ability of wildland fire to create barriers that limit the spread of subsequent fire along a gradient representing time between fires in four large study areas in the western United States. Using fire progression maps in conjunction with weather station data, we also evaluated the influence of daily weather. Results indicate that wildland fire does limit subsequent fire spread in all four study areas, but this effect decays over time; wildland fire no longer limits subsequent fire spread 6-18 years after fire, depending on the study area. We also found that the ability of fire to regulate, subsequent fire progression was substantially reduced under extreme conditions compared to moderate weather conditions in all four study areas. This study increases understanding of the spatial feedbacks that can lead to self-regulating landscapes as well as the effects of top-down controls, such as weather, on these feedbacks. Our results will be useful to managers who seek to restore natural fire regimes or to exploit recent burns when managing fire.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 3 2010-10-01 2010-10-01 false Training. 194.117 Section 194.117 Transportation... Response Plans § 194.117 Training. (a) Each operator shall conduct training to ensure that: (1) All... of equipment, fire suits, and breathing apparatus. (b) Each operator shall maintain a training record...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 3 2011-10-01 2011-10-01 false Training. 194.117 Section 194.117 Transportation... Response Plans § 194.117 Training. (a) Each operator shall conduct training to ensure that: (1) All... of equipment, fire suits, and breathing apparatus. (b) Each operator shall maintain a training record...
2011-11-17
to emulate typical impact area conditions. The Open Field area is now divided into four subareas: Legacy, Indirect fire, Direct fire, and Challenge...that could be typically found at an impact area of an indirect fire weapons range. These are 81 mm and 60 mm mortars and 105 ALLTEM APG...munitions. • Open field (direct fire) The direct fire subarea contains only three munition types that could be typically found at an impact area of
Sankaranarayanan, Ganesh; Wooley, Lizzy; Hogg, Deborah; Dorozhkin, Denis; Olasky, Jaisa; Chauhan, Sanket; Fleshman, James W; De, Suvranu; Scott, Daniel; Jones, Daniel B
2018-01-25
SAGES FUSE curriculum provides didactic knowledge on OR fire prevention. The objective of this study is to evaluate the impact of an immersive virtual reality (VR)-based OR fire training simulation system in combination with FUSE didactics. The study compared a control with a simulation group. After a pre-test questionnaire that assessed the baseline knowledge, both groups were given didactic material that consists of a 10-min presentation and reading materials about precautions and stopping an OR fire from the FUSE manual. The simulation group practiced on the OR fire simulation for one session that consisted of five trials within a week from the pre-test. One week later, both groups were reassessed using a questionnaire. A week after the post-test both groups also participated in a simulated OR fire scenario while their performance was videotaped for assessment. A total of 20 subjects (ten per group) participated in this IRB approved study. Median test scores for the control group increased from 5.5 to 9.00 (p = 0.011) and for the simulation group it increased from 5.0 to 8.5 (p = 0.005). Both groups started at the same baseline (pre-test, p = 0.529) and reached similar level in cognitive knowledge (post-test, p = 0.853). However, when tested in the mock OR fire scenario, 70% of the simulation group subjects were able to perform the correct sequence of steps in extinguishing the simulated fire whereas only 20% subjects in the control group were able to do so (p = 0.003). The simulation group was better than control group in correctly identifying the oxidizer (p = 0.03) and ignition source (p = 0.014). Interactive VR-based hands-on training was found to be a relatively inexpensive and effective mode for teaching OR fire prevention and management scenarios.
Rose, Eli T.; Simons, Theodore R.
2016-01-01
Fire suppression in southern Appalachian pine–oak forests during the past century dramatically altered the bird community. Fire return intervals decreased, resulting in local extirpation or population declines of many bird species adapted to post-fire plant communities. Within Great Smoky Mountains National Park, declines have been strongest for birds inhabiting xeric pine–oak forests that depend on frequent fire. The buildup of fuels after decades of fire suppression led to changes in the 1996 Great Smoky Mountains Fire Management Plan. Although fire return intervals remain well below historic levels, management changes have helped increase the amount of fire within the park over the past 20 years, providing an opportunity to study patterns of fire severity, time since burn, and bird occurrence. We combined avian point counts in burned and unburned areas with remote sensing indices of fire severity to infer temporal changes in bird occurrence for up to 28 years following fire. Using hierarchical linear models that account for the possibility of a species presence at a site when no individuals are detected, we developed occurrence models for 24 species: 13 occurred more frequently in burned areas, 2 occurred less frequently, and 9 showed no significant difference between burned and unburned areas. Within burned areas, the top models for each species included fire severity, time since burn, or both, suggesting that fire influenced patterns of species occurrence for all 24 species. Our findings suggest that no single fire management strategy will suit all species. To capture peak occupancy for the entire bird community within xeric pine–oak forests, at least 3 fire regimes may be necessary; one applying frequent low severity fire, another using infrequent low severity fire, and a third using infrequently applied high severity fire.
[Forest fire division by using MODIS data based on the temporal-spatial variation law].
He, Cheng; He, Cheng; Gong, Yin-xi; Zhang, Si-yu; He, Teng-fei; Chen, Feng; Sun, Yu; Feng, Zhong-ke
2013-09-01
Forest fires are harmful to the ecological environment, which have induced global attention. In the present paper fire activities extracted from MODIS and burned areas were compared, and it was found that the wave band of 8-9 extracted from MOD14A1 was useful for fire monitoring, and the data accorded with field investigation with goodness of fit reaching up to 0. 83. Through combining this wave band and the relative data to make the time and space analysis of the forest fires for 11 years, from 2000 to 2010, the study showed that the fire occurred most frequently in the spring, the autumn took the second place, and in the summer there was almost no fire occurrence unless drought. Through the analysis of the research area, the burned areas of the coniferous forest and temperate mixed forest were 53.68% and 44%, respectively, while the grassland was only 2.32%. Da Hinggan Ling region was the main combustion area, the burned areas were 64.7% and that for Xiao Hinggan Ling was about 23.49%, while those for other areas were less than 5%. The majority of forest land of burned areas has a gentle slope (< or =5 percent), and is in the middle altitude between 200 and 500 m. So, using satellite remote sensing to analyze the time series of burned areas in forests would make the relationship between the fire activities, climate change, topography and vegetation type clear and it is also helpful to predicting the risk level of the fire areas.
Trends in fire risk and burned area in Brazil in the 20th century
NASA Astrophysics Data System (ADS)
Silva, P.; Bastos, A.; DaCamara, C.; Libonati, R.
2016-12-01
Fire has a significant contribution to the global greenhouse gas emissions and vast ecological and climatic impacts. Worldwide, Brazil is one of the areas most affected by fire, which highly influences the state of the vegetation cover, the ecological diversity of the region and has significant consequences to the global CO2 balance [1]. Hence, with the increasing evidence of human induced climate change, it becomes essential to understand the present and future trends of fire risk in Brazil. Although a large number of fires in Brazil are anthropogenic, it has been shown that the burned area is mainly controlled by meteorological conditions [2], therefore being partially determined by fire risk. In this study we use a fire danger index specifically tailored for the Brazilian climate and biome characteristics, the MFDI developed by INPE, to assess the patterns and trends of fire risk in Brazil. The index relies on values of maximum temperature, accumulated precipitation over different periods, minimum relative humidity and vegetation cover to estimate the likelihood of fire occurrence. We test the sensitivity of the index to different climate reanalyses and evaluate the trends in fire risk in Brazil during the past four decades for different biomes. We further assess the link between the calculated fire risk and observed fire occurrence and burned area. Finally, we compare the results with fire risk simulated by a regional climate model (RCA4 forced by EC-Earth from CORDEX) in order to evaluate its suitability for future projections of fire risk and burned area. [1] Bowman, D. M. et al. Fire in the earth system. Science, v. 324, p. 481-484, 24 apr. 2009. [2] Libonati, R. et al. An Algorithm for Burned Area Detection in the Brazilian Cerrado Using 4 μm MODIS Imagery. Remote Sensing, v. 7, p. 15782-15803, 2015.
Calef, Monika; Varvak, Anna; McGuire, A. David
2017-01-01
In western North America, the carbon-rich boreal forest is experiencing warmer temperatures, drier conditions and larger and more frequent wildfires. However, the fire regime is also affected by direct human activities through suppression, ignition, and land use changes. Models are important predictive tools for understanding future conditions but they are based on regional generalizations of wildfire behavior and weather that do not adequately account for the complexity of human–fire interactions. To achieve a better understanding of the intensity of human influence on fires in this sparsely populated area and to quantify differences between human and lightning fires, we analyzed fires by both ignition types in regard to human proximity in urban (the Fairbanks subregion) and rural areas of interior Alaska using spatial (Geographic Information Systems) and quantitative analysis methods. We found substantial differences in drivers of wildfire: while increases in fire ignitions and area burned were caused by lightning in rural interior Alaska, in the Fairbanks subregion these increases were due to human fires, especially in the wildland urban interface. Lightning fires are starting earlier and fires are burning longer, which is much more pronounced in the Fairbanks subregion than in rural areas. Human fires differed from lightning fires in several ways: they started closer to settlements and highways, burned for a shorter duration, were concentrated in the Fairbanks subregion, and often occurred outside the brief seasonal window for lightning fires. This study provides important insights that improve our understanding of the direct human influence on recently observed changes in wildfire regime with implications for both fire modeling and fire management.
NASA Astrophysics Data System (ADS)
Wu, Minchao; Knorr, Wolfgang; Thonicke, Kirsten; Schurgers, Guy; Camia, Andrea; Arneth, Almut
2015-11-01
Global environmental changes and human activity influence wildland fires worldwide, but the relative importance of the individual factors varies regionally and their interplay can be difficult to disentangle. Here we evaluate projected future changes in burned area at the European and sub-European scale, and we investigate uncertainties in the relative importance of the determining factors. We simulated future burned area with LPJ-GUESS-SIMFIRE, a patch-dynamic global vegetation model with a semiempirical fire model, and LPJmL-SPITFIRE, a dynamic global vegetation model with a process-based fire model. Applying a range of future projections that combine different scenarios for climate changes, enhanced CO2 concentrations, and population growth, we investigated the individual and combined effects of these drivers on the total area and regions affected by fire in the 21st century. The two models differed notably with respect to the dominating drivers and underlying processes. Fire-vegetation interactions and socioeconomic effects emerged as important uncertainties for future burned area in some European regions. Burned area of eastern Europe increased in both models, pointing at an emerging new fire-prone region that should gain further attention for future fire management.
Syphard, Alexandra D; Radeloff, Volker C; Hawbaker, Todd J; Stewart, Susan I
2009-06-01
Periodic wildfire is an important natural process in Mediterranean-climate ecosystems, but increasing fire recurrence threatens the fragile ecology of these regions. Because most fires are human-caused, we investigated how human population patterns affect fire frequency. Prior research in California suggests the relationship between population density and fire frequency is not linear. There are few human ignitions in areas with low population density, so fire frequency is low. As population density increases, human ignitions and fire frequency also increase, but beyond a density threshold, the relationship becomes negative as fuels become sparser and fire suppression resources are concentrated. We tested whether this hypothesis also applies to the other Mediterranean-climate ecosystems of the world. We used global satellite databases of population, fire activity, and land cover to evaluate the spatial relationship between humans and fire in the world's five Mediterranean-climate ecosystems. Both the mean and median population densities were consistently and substantially higher in areas with than without fire, but fire again peaked at intermediate population densities, which suggests that the spatial relationship is complex and nonlinear. Some land-cover types burned more frequently than expected, but no systematic differences were observed across the five regions. The consistent association between higher population densities and fire suggests that regardless of differences between land-cover types, natural fire regimes, or overall population, the presence of people in Mediterranean-climate regions strongly affects the frequency of fires; thus, population growth in areas now sparsely settled presents a conservation concern. Considering the sensitivity of plant species to repeated burning and the global conservation significance of Mediterranean-climate ecosystems, conservation planning needs to consider the human influence on fire frequency. Fine-scale spatial analysis of relationships between people and fire may help identify areas where increases in fire frequency will threaten ecologically valuable areas. ©2009 Society for Conservation Biology.
Using unplanned fires to help suppressing future large fires in Mediterranean forests.
Regos, Adrián; Aquilué, Núria; Retana, Javier; De Cáceres, Miquel; Brotons, Lluís
2014-01-01
Despite the huge resources invested in fire suppression, the impact of wildfires has considerably increased across the Mediterranean region since the second half of the 20th century. Modulating fire suppression efforts in mild weather conditions is an appealing but hotly-debated strategy to use unplanned fires and associated fuel reduction to create opportunities for suppression of large fires in future adverse weather conditions. Using a spatially-explicit fire-succession model developed for Catalonia (Spain), we assessed this opportunistic policy by using two fire suppression strategies that reproduce how firefighters in extreme weather conditions exploit previous fire scars as firefighting opportunities. We designed scenarios by combining different levels of fire suppression efficiency and climatic severity for a 50-year period (2000-2050). An opportunistic fire suppression policy induced large-scale changes in fire regimes and decreased the area burnt under extreme climate conditions, but only accounted for up to 18-22% of the area to be burnt in reference scenarios. The area suppressed in adverse years tended to increase in scenarios with increasing amounts of area burnt during years dominated by mild weather. Climate change had counterintuitive effects on opportunistic fire suppression strategies. Climate warming increased the incidence of large fires under uncontrolled conditions but also indirectly increased opportunities for enhanced fire suppression. Therefore, to shift fire suppression opportunities from adverse to mild years, we would require a disproportionately large amount of area burnt in mild years. We conclude that the strategic planning of fire suppression resources has the potential to become an important cost-effective fuel-reduction strategy at large spatial scale. We do however suggest that this strategy should probably be accompanied by other fuel-reduction treatments applied at broad scales if large-scale changes in fire regimes are to be achieved, especially in the wider context of climate change.
A systematic conservation planning approach to fire risk management in Natura 2000 sites.
Foresta, Massimiliano; Carranza, Maria Laura; Garfì, Vittorio; Di Febbraro, Mirko; Marchetti, Marco; Loy, Anna
2016-10-01
A primary challenge in conservation biology is to preserve the most representative biodiversity while simultaneously optimizing the efforts associated with conservation. In Europe, the implementation of the Natura 2000 network requires protocols to recognize and map threats to biodiversity and to identify specific mitigation actions. We propose a systematic conservation planning approach to optimize management actions against specific threats based on two fundamental parameters: biodiversity values and threat pressure. We used the conservation planning software Marxan to optimize a fire management plan in a Natura 2000 coastal network in southern Italy. We address three primary questions: i) Which areas are at high fire risk? ii) Which areas are the most valuable for threatened biodiversity? iii) Which areas should receive priority risk-mitigation actions for the optimal effect?, iv) which fire-prevention actions are feasible in the management areas?. The biodiversity values for the Natura 2000 spatial units were derived from the distribution maps of 18 habitats and 89 vertebrate species of concern in Europe (Habitat Directive 92/43/EEC). The threat pressure map, defined as fire probability, was obtained from digital layers of fire risk and of fire frequency. Marxan settings were defined as follows: a) planning units of 40 × 40 m, b) conservation features defined as all habitats and vertebrate species of European concern occurring in the study area, c) conservation targets defined according with fire sensitivity and extinction risk of conservation features, and d) costs determined as the complement of fire probabilities. We identified 23 management areas in which to concentrate efforts for the optimal reduction of fire-induced effects. Because traditional fire prevention is not feasible for most of policy habitats included in the management areas, alternative prevention practices were identified that allows the conservation of the vegetation structure. The proposed approach has potential applications for multiple landscapes, threats and spatial scales and could be extended to other valuable natural areas, including protected areas. Copyright © 2016 Elsevier Ltd. All rights reserved.
30 CFR 57.4362 - Underground rescue and firefighting operations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4362 Underground rescue and firefighting operations. Following evacuation of a mine in a fire emergency, only persons wearing and trained...
30 CFR 57.4362 - Underground rescue and firefighting operations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4362 Underground rescue and firefighting operations. Following evacuation of a mine in a fire emergency, only persons wearing and trained...
30 CFR 57.4362 - Underground rescue and firefighting operations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4362 Underground rescue and firefighting operations. Following evacuation of a mine in a fire emergency, only persons wearing and trained...
Variable carbon losses from recurrent fires in drained tropical peatlands.
Konecny, Kristina; Ballhorn, Uwe; Navratil, Peter; Jubanski, Juilson; Page, Susan E; Tansey, Kevin; Hooijer, Aljosja; Vernimmen, Ronald; Siegert, Florian
2016-04-01
Tropical peatland fires play a significant role in the context of global warming through emissions of substantial amounts of greenhouse gases. However, the state of knowledge on carbon loss from these fires is still poorly developed with few studies reporting the associated mass of peat consumed. Furthermore, spatial and temporal variations in burn depth have not been previously quantified. This study presents the first spatially explicit investigation of fire-driven tropical peat loss and its variability. An extensive airborne Light Detection and Ranging data set was used to develop a prefire peat surface modelling methodology, enabling the spatially differentiated quantification of burned area depth over the entire burned area. We observe a strong interdependence between burned area depth, fire frequency and distance to drainage canals. For the first time, we show that relative burned area depth decreases over the first four fire events and is constant thereafter. Based on our results, we revise existing peat and carbon loss estimates for recurrent fires in drained tropical peatlands. We suggest values for the dry mass of peat fuel consumed that are 206 t ha(-1) for initial fires, reducing to 115 t ha(-1) for second, 69 t ha(-1) for third and 23 t ha(-1) for successive fires, which are 58-7% of the current IPCC Tier 1 default value for all fires. In our study area, this results in carbon losses of 114, 64, 38 and 13 t C ha(-1) for first to fourth fires, respectively. Furthermore, we show that with increasing proximity to drainage canals both burned area depth and the probability of recurrent fires increase and present equations explaining burned area depth as a function of distance to drainage canal. This improved knowledge enables a more accurate approach to emissions accounting and will support IPCC Tier 2 reporting of fire emissions. © 2015 John Wiley & Sons Ltd.
González-De Vega, S; De Las Heras, J; Moya, D
2016-12-15
In recent decades, the fire regime of the Mediterranean Basin has been disturbed by various factors: climate change; forest management policies; land cover; changed landscape. Size and severity have notably increased, which in turn have increased large fires events with >500ha burned (high severity). In spite of Mediterranean ecosystems' high resilience to fire, these changes have implied more vulnerability and reduced natural recovery with irreparable long-term negative effects. Knowledge of the response of ecosystems to increasing severity, mainly in semiarid areas, is still lacking, which is needed to rehabilitate and restore burned areas. Our approach assessed the resilience concept by focusing on the recovery of ecosystem functions and services, measured as changes in the composition and diversity of plant community vegetation and structure. This will be validated in the long term as a model of ecosystem response. Also, depending on the pre-fire characteristics of vegetation, fire severity and the post-fire management, this approach will lead to tools that can be applied to implement post-fire restoration efforts in order to help decision making in planning activities. Regarding Mediterranean ecosystems' ability to recover after wildfires, this study concludes that pre-fire communities are resilient in these fire-prone areas, but the window for natural recovery in semiarid areas of Aleppo pine forest in SE Iberian Peninsula varied from 3 to 15 post-fire years. Fire severity was also key for effects on the ecosystem: the vegetation types of areas burned with low and medium severity recovered naturally, while those areas with a high-severity burn induced shrublands. We concluded that very strong regeneration activity exists in the short term, and that the negative effects of medium- and high-severity fire are evidenced in the mid and long term, which affect natural recovery. Adaptive forest management to rehabilitate and restore burned Mediterranean ecosystems should be implemented. Copyright © 2016 Elsevier B.V. All rights reserved.
Modeling the Effects of Fire Frequency and Severity on Forests in the Northwestern United States
Busing, Richard T.; Solomon, Allen M.
2006-01-01
This study used a model of forest dynamics (FORCLIM) and actual forest survey data to demonstrate the effects of various fire regimes on different forest types in the Pacific Northwest. We examined forests in eight ecoregions ranging from wet coastal forests dominated by Pseudotsuga menziesii and other tall conifers to dry interior forests dominated by Pinus ponderosa. Fire effects simulated as elevated mortality of trees based on their species and size did alter forest structure and species composition. Low frequency fires characteristic of wetter forests (return interval >200 yr) had minor effects on composition. When fires were severe, they tended to reduce total basal area with little regard to species differences. High frequency fires characteristic of drier forests (return interval <30 yr) had major effects on species composition and on total basal area. Typically, they caused substantial reductions in total basal area and shifts in dominance toward highly fire tolerant species. With the addition of fire, simulated basal areas averaged across ecoregions were reduced to levels approximating observed basal areas.
Akay, Abdullah E; Wing, Michael G; Sivrikaya, Fatih; Sakar, Dursun
2012-03-01
The ability of firefighting vehicles and staff to reach a fire area as quickly as possible is critical in fighting against forest fires. In this study, a Geographical Information System-based decision support system was developed to assist fire managers in determining the fastest and the safest or more reliable access routes from firefighting headquarters to fire areas. The decision support system was tested in the Kahramanmaras Forestry Regional Directoratein the Mediterranean region of Turkey. The study area consisted of forested lands which had been classified according to fire sensitivity. The fire response routing simulations considered firefighting teams located in 20 firefighting headquarter locations. The road network, the locations of the firefighting headquarters, and possible fire locations were mapped for simulation analysis. In alternative application simulations, inaccessible roads which might be closed due to fire or other reasons were indicated in the network analysis so that the optimum route was not only the fastest but also the safest and most reliable path. The selection of which firefighting headquarters to use was evaluated by considering critical response time to potential fire areas based on fire sensitivity levels. Results indicated that new firefighting headquarters should be established in the region in order to provide sufficient firefighting response to all forested lands. In addition, building new fire access roads and increasing the design speed on current roads could also increase firefighting response capabilities within the study area.
Karin L. Riley; Rachel A. Loehman
2016-01-01
Climate changes are expected to increase fire frequency, fire season length, and cumulative area burned in the western United States. We focus on the potential impact of mid-21st- century climate changes on annual burn probability, fire season length, and large fire characteristics including number and size for a study area in the Northern Rocky Mountains....
Podur, Justin J; Martell, David L
2009-07-01
Forest fires are influenced by weather, fuels, and topography, but the relative influence of these factors may vary in different forest types. Compositional analysis can be used to assess the relative importance of fuels and weather in the boreal forest. Do forest or wild land fires burn more flammable fuels preferentially or, because most large fires burn in extreme weather conditions, do fires burn fuels in the proportions they are available despite differences in flammability? In the Canadian boreal forest, aspen (Populus tremuloides) has been found to burn in less than the proportion in which it is available. We used the province of Ontario's Provincial Fuels Database and fire records provided by the Ontario Ministry of Natural Resources to compare the fuel composition of area burned by 594 large (>40 ha) fires that occurred in Ontario's boreal forest region, a study area some 430,000 km2 in size, between 1996 and 2006 with the fuel composition of the neighborhoods around the fires. We found that, over the range of fire weather conditions in which large fires burned and in a study area with 8% aspen, fires burn fuels in the proportions that they are available, results which are consistent with the dominance of weather in controlling large fires.
Polyfluoroalkyl Substances ( PFAS ), like perfluorooctanoic acid, have been used for the last 50 years in a wide variety of industrial processes and...The Department of Defense (DoD) has used PFAS -based Aqueous Film Forming Foam (AFFF) at fire training facilities and aircraft hangars. These AFFFs have...contaminated approximately 600 sites classified as fire training facilities with PFAS (Huang, 2013). This study focused on testing the most likely
Burnt area detection and hotspot analysis of wildfires in Margalla Hills National Park
NASA Astrophysics Data System (ADS)
Khalid, Noora; Ullah, Saleem
2016-07-01
Wildfires have been a growing source for the forest degradation and reduction in carbon sequestration which cause climate change and global warming. Thus, severely affect the ecosystem when not checked. Studies have revealed that land managements that do not use fire reduce the fire incidents by as much as 69 percent. This study focuses on mapping the areas burnt by forest fires owing to both natural and anthropogenic causes and identifying the fire prone areas in biodiversity spot of Islamabad, Margalla Hills National Park. The methodology employed based on using remotely sensed data with the integration of GIS techniques to estimate the area in hectares turned to ashes which ensued from forest fires during summers of 2008, 2010 and 2011 by applying Normalized Burn Ratio. Moreover hotspot analysis has also been used to pin point the locations with frequent fire incidents in the past using Global Positioning System (GPS) acquired coordinates from the fire surveys and official burned area statistics. The results revealed that wildfires destroyed some common regions in three years towards west which comprise of dense woodland comprising mainly Acacia Modesta, Dalbergia sissoo and Pinus longifolia. The calculated burnt area was 516 hectares, 122 hectares and 45 hectares for 2008, 2010 and 2011 respectively. Although a decline in burnt area has been observed owing to responsible management of authorities and development of fire pickets, still measures need to be taken to eradicate the core causes in charge of these fires and to promote reforestation. This study will allow policy makers and regulatory authorities to identify risk prone areas which will assist them in formulating a strategy to suppress fire incidents.
Shock sensing dual mode warhead
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shamblen, M.; Walchak, M.T.; Richmond, L.
1980-12-31
A shock sensing dual mode warhead is provided for use against both soft and hard targets and is capable of sensing which type of target has been struck. The warhead comprises a casing made of a ductile material containing an explosive charge and a fuze assembly. The ductile warhead casing will mushroom upon striking a hard target while still confining the explosive. Proper ductility and confinement are necessary for fuze shock sensing. The fuze assembly contains a pair of parallel firing trains, one initiated only by dynamic pressure caused high impact deceleration and one initiated by low impact deceleration. Themore » firing train actuated by high impact deceleration senses dynamic pressure transmitted, during deformation of the warhead, through the explosive filler which is employed as a fuzing signature. The firing train actuated by low impact deceleration contains a pyrotechnic delay to allow penetration of soft targets.« less
Millisecond-Scale Motor Encoding in a Cortical Vocal Area
NASA Astrophysics Data System (ADS)
Nemenman, Ilya; Tang, Claire; Chehayeb, Diala; Srivastava, Kyle; Sober, Samuel
2015-03-01
Studies of motor control have almost universally examined firing rates to investigate how the brain shapes behavior. In principle, however, neurons could encode information through the precise temporal patterning of their spike trains as well as (or instead of) through their firing rates. Although the importance of spike timing has been demonstrated in sensory systems, it is largely unknown whether timing differences in motor areas could affect behavior. We tested the hypothesis that significant information about trial-by-trial variations in behavior is represented by spike timing in the songbird vocal motor system. We found that neurons in motor cortex convey information via spike timing far more often than via spike rate and that the amount of information conveyed at the millisecond timescale greatly exceeds the information available from spike counts. These results demonstrate that information can be represented by spike timing in motor circuits and suggest that timing variations evoke differences in behavior. This work was supported in part by the National Institutes of Health, National Science Foundation, and James S. McDonnell Foundation
Bugna, G C; Chanton, J P; Stauffer, T B; MacIntyre, W G; Libelo, E L
2005-07-01
The relative importance of jet fuel biodegradation relative to the respiration of natural organic matter in a contaminated organic-rich aquifer underlying a fire training area at Tyndall Air Force Base, Florida, USA was determined with isotopic measurements. Thirteen wells were sampled and analyzed for BTX (benzene, toluene, xylene), dissolved inorganic carbon (DIC) and CH4 concentrations, and delta13C and 14C of DIC. Results range from non-detectable to 3790 ppb, 1.4-24 mM, 0.2-776 microM, +5.8 per thousand to -22 per thousand, and from 52 to 99 pmc, respectively. Residual fuel was confined to two center wells underlying the fire training area. DIC and CH4 concentrations were elevated down-gradient of the contamination, but also at sites that were not in the apparent flow path of the contaminated groundwater. DIC exhibited greatest delta13C enrichment at highest DIC and CH4 concentrations indicating that CH4 production was an important respiration mode. Radiocarbon-depleted DIC was observed at sites with high hydrocarbon concentrations and down-gradient of the site. The results indicate that while natural attenuation was not rapidly reducing the quantity of free product overlying the aquifer at the site of contamination, it was at least constraining its flow away from the spill site. Apparently under the conditions of this study, BTX was degraded as rapidly as it was dissolved.
The dynamics of fire regimes in tropical peatlands in Central Kalimantan, Borneo
NASA Astrophysics Data System (ADS)
Hoscilo, Agata; Page, Susan; Tansey, Kevin
2010-05-01
As a carbon-rich ecosystem, tropical peatland contributes significantly to terrestrial carbon storage and stability of the global carbon cycle. Vast areas of tropical peatland in SE Asia are degraded by the increasingly intensive scale of human activities, illustrated by high rates of deforestation, poor land-use management, selective illegal logging, and frequently repeated fires. Analysis of time-series satellite images performed in this study confirmed that fire regimes have dramatically changed in tropical peatlands over the last three decades (1973-2005). The study was conducted in the southern part of Central Kalimantan (Indonesian Borneo). We found that there was an evident increase in fire frequency and a decline in the fire return interval after implementation of the Mega Rice Project (1997-2005). Up until 1997, fires had affected a relatively small area, in total 23% of the study area, and were largely related to land clearance. This situation changed significantly during the last decade (1997-2005), when the widespread, intensive fires of 1997 affected a much larger area. Five years later, in 2002, extensive fires returned, affecting again 22% of the study area. Then, in 2004 and 2005, a further large area of peatland was on fire. Fire frequency analysis showed that during the period 1997-2005, around 45% of the study area was subject to multiple fires, with 37% burnt twice and 8% burnt three or more times. Near-annual occurrence of fire events reduces the rate and nature of vegetation regrowth. Hence, we observed a shift in the fire fuel type and amount over the period of investigation. After 1997, the fire fuel shifted from mainly peat swamp forest biomass towards non-woody biomass, dominated by regenerating vegetation, mainly ferns and a few trees. This secondary vegetation has been shown to be fire prone, although fire propagation is slower than in forest and restricted by both low fuel quality and load. Furthermore, we investigated the interaction between human impacts and presence and extent of fires. We found that the majority of fire events were directly or indirectly associated with human activities (i.e. selective logging, land clearance, intensive drainage and transmigration re-settlement). The intensive drainage infrastructure associated with the Mega Rice Project initiative greatly impaired the peatland hydrological system, increasing the risk of fire. In addition, the network of canals allowed easy access for people whose activities provided ignition sources. Hence, multiple fires were located within close proximity to canals and declined with distance away from canals. These results emphasise the vulnerability of degraded tropical peatlands to fire and confirm that widespread and intensive fires have become an integral part of tropical peatland ecosystem and are now associated with most dry seasons.
Isobe, Kazuo; Otsuka, Shigeto; Sudiana, Imade; Nurkanto, Arif; Senoo, Keishi
2009-10-01
Soil bacterial community compositions in burnt and unburnt areas in a tropical rainforest in East Kalimantan, Indonesia, were investigated 8 and 9 years after a fire by denaturing gradient gel electrophoresis analysis targeting the 16S rRNA gene. Three study sites were set in the forest area devoid of fire damage (control), and in the lightly damaged and heavily damaged forest areas. Succession of aboveground vegetation in the two damaged areas had clearly proceeded after the fire, but the vegetation types still differed from the unburnt area at the time of this study. Community composition of total soil bacteria was similar among the three areas, and so was that of actinobacteria. However, the composition of ammonia oxidizing bacteria clearly differed depending on the presence or absence of past fire damage. These results indicate that even nearly a decade after the forest fire, impacts of the fire remained on the community composition of ammonia oxidizing bacteria, but not apparently on those of dominant bacteria and actinobacteria.
Andersen, Maria Helena Guerra; Saber, Anne Thoustrup; Pedersen, Peter Bøgh; Loft, Steffen; Hansen, Åse Marie; Koponen, Ismo Kalevi; Pedersen, Julie Elbæk; Ebbehøj, Niels; Nørskov, Eva-Carina; Clausen, Per Axel; Garde, Anne Helene; Vogel, Ulla; Møller, Peter
2017-09-06
Firefighters have increased risk of cardiovascular disease and of sudden death from coronary heart disease on duty while suppressing fires. This study investigated the effect of firefighting activities, using appropriate personal protective equipment (PPE), on biomarkers of cardiovascular effects in young conscripts training to become firefighters. Healthy conscripts (n = 43) who participated in a rescue educational course for firefighting were enrolled in the study. The exposure period consisted of a three-day training course where the conscripts participated in various firefighting exercises in a constructed firehouse and flashover container. The subjects were instructed to extinguish fires of either wood or wood with electrical cords and mattresses. The exposure to particulate matter (PM) was assessed at various locations and personal exposure was assessed by portable PM samplers and urinary excretion of 1-hydroxypyrene. Cardiovascular measurements included microvascular function and heart rate variability (HRV). The subjects were primarily exposed to PM in bystander positions, whereas self-contained breathing apparatus effectively abolished pulmonary exposure. Firefighting training was associated with elevated urinary excretion of 1-hydroxypyrene (105%, 95% CI: 52; 157%), increased body temperature, decreased microvascular function (-18%, 95% CI: -26; -9%) and altered HRV. There was no difference in cardiovascular measurements for the two types of fires. Observations from this fire extinction training show that PM exposure mainly occurs in situations where firefighters removed the self-contained breathing apparatus. Altered cardiovascular disease endpoints after the firefighting exercise period were most likely due to complex effects from PM exposure, physical exhaustion and increased core body temperature.
Fire Safety Trianing in Health Care Institutions.
ERIC Educational Resources Information Center
American Hospital Association, Chicago, IL.
The manual details the procedures to be followed in developing and implementing a fire safety plan. The three main steps are first, to organize; second, to set up a procedure and put it in writing; and third, to train and drill employees and staff. Step 1 involves organizing a safety committee, appointing a fire marshall, and seeking help from…
Simulating Building Fires for Movies
NASA Technical Reports Server (NTRS)
Rodriguez, Ricardo C.; Johnson, Randall P.
1987-01-01
Fire scenes for cinematography staged at relatively low cost in method that combines several existing techniques. Nearly realistic scenes, suitable for firefighter training, produced with little specialized equipment. Sequences of scenes set up quickly and easily, without compromising safety because model not burned. Images of fire, steam, and smoke superimposed on image of building to simulate burning of building.
Safety. Fire Service Certification Series. Unit FSCS-FF-2-80.
ERIC Educational Resources Information Center
Pribyl, Paul F.
This training unit on safety is part of a 17-unit course package written to aid instructors in the development, teaching, and evaluation of fire fighters in the Wisconsin Fire Service Certification Series. The purpose stated for the 4-hour unit is to assist firefighters in understanding the hazards of their profession and some methods of reducing…
ERIC Educational Resources Information Center
Rupe, Marvin L.; And Others
The Long Beach Fire Department (California), developed a program to foster and improve the development of future fire department managers who are promoted from within the department. A 10-day orientation program was developed. The competency-based program featured a mix of management-leadership training (the nature of leadership, personnel…
NASA Technical Reports Server (NTRS)
1984-01-01
Firefighting trainees conduct fire control exercises using a prototype simulator known as the Emergency Management Computer Aided Training System (EMCAT). Developed by Marshall Space Flight Center (MFS) in response to a request from the Huntsville (AL) Fire Department, EMCAT enables a trainee to assume the role of fireground commander and make quick decisions on best use of his fire fighting personnel and equipment.
NASA Astrophysics Data System (ADS)
Gómez-Nieto, Israel; Martín, María del Pilar; Salas, Francisco Javier; Gallardo, Marta
2013-04-01
Understanding the interaction between natural and socio-economic factors that determine fire regime is essential to make accurate projections and impact assessments. However, this requires having accurate historical, systematic, homogeneous and spatially explicit information on fire occurrence. Fire databases usually have serious limitations in this regard; therefore other sources of information, such as remote sensing, have emerged as alternatives to generate optimal fire maps on various spatial and temporal scales. Several national and international projects work in order to generate information to study the factors that determine the current fire regime and its future evolution. This work is included in the framework of the project "Forest fires under climate, social and economic Changes in Europe, the Mediterranean and other fire-affected areas of the World" (FUME http://www.fumeproject.eu), which aims to study the changes and factors related to fire regimes through time to determine the potential impacts on vegetation in Mediterranean regions and concrete steps to address future risk scenarios. We analyzed the changes in the fire regime in Madrid region (Spain) in the past three decades (1984-2010) and its relation to land use changes. We identified and mapped fires that have occurred in the region during those years using Landsat satellite images by combining digital techniques and visual analysis. The results show a clear cyclical behaviour of the fire, with years of high incidence (as 1985, 2000 and 2003, highlighted by the number of fires and the area concerned, over 2000 ha) followed by another with a clear occurrence decrease. At the same time, we analyzed the land use changes that have occurred in Madrid region between the early 80s and mid-2000s using as reference the CORINE Land-cover maps (1990, 2000 and 2006) and the Vegetation and Land Use map of the Community of Madrid, 1982. We studied the relationship between fire regimes and observed land-use and land-cover changes in the periods analyzed, it was determined that between years 1984 and 2006 most of the burned area remained pre-fire cover type (above 80% of the area). However, in areas that experienced change, the most important transitions were recorded in wooded areas, especially conifers, which became shrubs or sparsely vegetated areas, followed by non-irrigated crops, which were replaced by grasslands or industrial areas, and sparse vegetation which changed to shrubs. Finally, the analysis of land-use changes over burned areas situated shrubland as the most favored type of cover, either as a result of a vegetative degradation process after intense burning of wooded areas, especially conifers, or as stage of natural increase in areas previously covered by sparsely vegetation.
Using Unplanned Fires to Help Suppressing Future Large Fires in Mediterranean Forests
Regos, Adrián; Aquilué, Núria; Retana, Javier; De Cáceres, Miquel; Brotons, Lluís
2014-01-01
Despite the huge resources invested in fire suppression, the impact of wildfires has considerably increased across the Mediterranean region since the second half of the 20th century. Modulating fire suppression efforts in mild weather conditions is an appealing but hotly-debated strategy to use unplanned fires and associated fuel reduction to create opportunities for suppression of large fires in future adverse weather conditions. Using a spatially-explicit fire–succession model developed for Catalonia (Spain), we assessed this opportunistic policy by using two fire suppression strategies that reproduce how firefighters in extreme weather conditions exploit previous fire scars as firefighting opportunities. We designed scenarios by combining different levels of fire suppression efficiency and climatic severity for a 50-year period (2000–2050). An opportunistic fire suppression policy induced large-scale changes in fire regimes and decreased the area burnt under extreme climate conditions, but only accounted for up to 18–22% of the area to be burnt in reference scenarios. The area suppressed in adverse years tended to increase in scenarios with increasing amounts of area burnt during years dominated by mild weather. Climate change had counterintuitive effects on opportunistic fire suppression strategies. Climate warming increased the incidence of large fires under uncontrolled conditions but also indirectly increased opportunities for enhanced fire suppression. Therefore, to shift fire suppression opportunities from adverse to mild years, we would require a disproportionately large amount of area burnt in mild years. We conclude that the strategic planning of fire suppression resources has the potential to become an important cost-effective fuel-reduction strategy at large spatial scale. We do however suggest that this strategy should probably be accompanied by other fuel-reduction treatments applied at broad scales if large-scale changes in fire regimes are to be achieved, especially in the wider context of climate change. PMID:24727853
NASA Astrophysics Data System (ADS)
Parente, Joana; Pereira, Mário; Amraoui, Malik; Tedim, Fantina
2017-04-01
The European Mediterranean countries, such as Portugal, Spain, France, Italy and Greece, have the higher incidence of fire. Of these countries, Portugal present the highest average number of fires (NF) and one of the highest burnt area (BA), in spite of its relatively smaller land area. The study period is focused in the recent years of 2012 - 2014, when a total of 59 257 fires were recorded and the fire cause is known for more than 50% of the fire records. All fires with known causes were then classified into intentional (40% of the total number of fires) and negligent (60%), leading to a total of 45% of fires related with human factors and activities. Taking into account these values the authors believe it's necessary to better understand the fire regime of this type of fires for a better fire prevention, firefighting and crisis management. Accordingly, the use of statistical analysis and GIS techniques were used to assess the spatial distribution of the human caused fires in each of the NUTS (Nomenclature of Territorial Units for Statistics level I, which divides Portugal in 5 basic economic regions, namely Norte, Centro, Area Metropolitana de Lisboa, Alentejo, and Algarve. The number of fires distribution increases with latitude, making north of Portugal the region with the highest number of fires. The analysis will also aims to assess the role of the most important human and biophysical drivers of the spatial distribution, namely the population density, land use land cover (LULC), distance to communication routes (roads and railways) and topographic variables (altitude, slope). The results show that: a) population density is highly and positively correlated with the agglomeration of fire ignitions, but doesn't imply highest burned area; b) burnt area increase with the distance to roads and altitude; and, c) 58% of the fires occurred on agriculture areas and 33% of fires occurred in forest and scrubs areas. Acknowledgements: This work was supported by: (i) the project Interact - Integrative Research in Environment,Agro-Chain and Technology, NORTE-01-0145-FEDER-000017, research line BEST, cofinanced by FEDER/NORTE 2020; (ii) the FIREXTR project, PTDC/ATP¬GEO/0462/2014; and, (iii) European Investment Funds by FEDER/COMPETE/POCI-Operacional Competitiveness and Internacionalization Programme, under Project POCI-01-0145-FEDER-006958 and National Funds by FCT - Portuguese Foundation for Science and Technology, under the project UID/AGR/04033. We are especially grateful to ICNF for providing the fire data.
Workplace safety and health programs, practices, and conditions in auto collision repair businesses.
Brosseau, L M; Bejan, A; Parker, D L; Skan, M; Xi, M
2014-01-01
This article describes the results of a pre-intervention safety assessment conducted in 49 auto collision repair businesses and owners' commitments to specific improvements. A 92-item standardized audit tool employed interviews, record reviews, and observations to assess safety and health programs, training, and workplace conditions. Owners were asked to improve at least one-third of incorrect, deficient, or missing (not in compliance with regulations or not meeting best practice) items, of which a majority were critical or highly important for ensuring workplace safety. Two-thirds of all items were present, with the highest fraction related to electrical safety, machine safety, and lockout/tagout. One-half of shops did not have written safety programs and had not conducted recent training. Many had deficiencies in respiratory protection programs and practices. Thirteen businesses with a current or past relationship with a safety consultant had a significantly higher fraction of correct items, in particular related to safety programs, up-to-date training, paint booth and mixing room conditions, electrical safety, and respiratory protection. Owners selected an average of 58% of recommended improvements; they were most likely to select items related to employee Right-to-Know training, emergency exits, fire extinguishers, and respiratory protection. They were least likely to say they would improve written safety programs, stop routine spraying outside the booth, or provide adequate fire protection for spray areas outside the booth. These baseline results suggest that it may be possible to bring about workplace improvements using targeted assistance from occupational health and safety professionals.
Fine-scale spatial climate variation and drought mediate the likelihood of reburning.
Parks, Sean A; Parisien, Marc-André; Miller, Carol; Holsinger, Lisa M; Baggett, Larry Scott
2018-03-01
In many forested ecosystems, it is increasingly recognized that the probability of burning is substantially reduced within the footprint of previously burned areas. This self-limiting effect of wildland fire is considered a fundamental emergent property of ecosystems and is partly responsible for structuring landscape heterogeneity (i.e., mosaics of different age classes), thereby reducing the likelihood of uncharacteristically large fires in regions with active fire regimes. However, the strength and longevity of this self-limiting phenomenon is not well understood in most fire-prone ecosystems. In this study, we quantify the self-limiting effect in terms of its strength and longevity for five fire-prone study areas in western North America and investigate how each measure varies along a spatial climatic gradient and according to temporal (i.e., annual) climatic variation. Results indicate that the longevity (i.e., number of years) of the self-limiting effect ranges between 15 yr in the warm and dry study area in the southwestern United States to 33 yr in the cold, northern study areas in located in northwestern Montana and the boreal forest of Canada. We also found that spatial climatic variation has a strong influence on wildland fire's self-limiting capacity. Specifically, the self-limiting effect within each study area was stronger and lasted longer in areas with low mean moisture deficit (i.e., wetter and cooler settings) compared to areas with high mean moisture deficit (warmer and drier settings). Last, our findings show that annual climatic variation influences wildland fire's self-limiting effect: drought conditions weakened the strength and longevity of the self-limiting effect in all study areas, albeit at varying magnitudes. Overall, our study provides support for the idea that wildland fire contributes to spatial heterogeneity in fuel ages that subsequently mediate future fire sizes and effects. However, our findings show that the strength and longevity of the self-limiting effect varies considerably according to spatial and temporal climatic variation, providing land and fire managers relevant information for effective planning and management of fire and highlighting that fire itself is an important factor contributing to fire-free intervals. © 2017 by the Ecological Society of America.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River... Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River, Maryland, danger zones. (a) Aerial firing range—(1) The danger zone. The waters...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River... Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River, Maryland, danger zones. (a) Aerial firing range—(1) The danger zone. The waters...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River... Chesapeake Bay, Point Lookout to Cedar Point; aerial and surface firing range and target area, U.S. Naval Air Station, Patuxent River, Maryland, danger zones. (a) Aerial firing range—(1) The danger zone. The waters...
NASA Astrophysics Data System (ADS)
Montorio Llovería, Raquel; Pérez-Cabello, Fernando; García-Martín, Alberto
2016-09-01
Fire severity can be assessed by identifying and quantifying the fractional abundance of post-fire ground cover types, an approach with great capacity to predict ecosystem response. Focused on shrubland formations of Mediterranean-type ecosystems, three burned areas (Ibieca and Zuera wildfires and Peñaflor experimental fire) were sampled in the summers of 2006 and 2007. Two different ground measurements were made for each of the 356 plots: (i) 3-band high spatial resolution photography (HSRP) and (ii) the hemispherical-conical reflectance factor (HCRF) in the visible to near-infrared spectral range (VNIR, 400-900 nm). Stepwise multiple lineal regression (SMLR) models were fitted to spectral variables (HCRF, first derivative spectra or FDS, and four absorption indices) to estimate the fractional cover of seven post-fire ground cover types (vegetation and soil - unburned and charred components - and ash - char and ash, individually and as a combined category). Models were developed and validated at the Peñaflor site (training, n = 217; validation, n = 88) and applied to the samples from the Ibieca and Zuera sites (n = 51). The best results were observed for the abundance estimations of green vegetation (Radj.20.70-0.90), unburned soil (Radj.20.40-0.75), and the combination of ashes (Radj.20.65-0.80). In comparison of spectral data, FDS outperforms reflectance or absorption data because of its higher accuracy levels and, importantly, its greater capacity to yield generalizable models. Future efforts should be made to improve the estimation of intermediate severity levels and upscaling the developed models. In the context of fire severity assessment, our study demonstrates the potential of hyperspectral data to estimate in a quick and objective manner post-fire ground cover fractions and thus provide valuable information to guide management responses.
NASA Astrophysics Data System (ADS)
Martinez-Alonso, S.; Deeter, M. N.; Worden, H. M.; Gille, J. C.; Clerbaux, C.; George, M.
2014-12-01
Deforestation fires in the Amazon Basin abound during the dry season (July to October) and are mostly associated with "slash and burn" agricultural practices. Understory fires occur when fires escape from deforested areas into neighboring standing forests; they spread slowly below the canopy, affecting areas that may be comparable or even larger than clear-cut areas. The interannual variabilities of understory fires and deforestation rates appear to be uncorrelated. Areas burned in understory fires are particularly extensive during droughts. Because they progress below a canopy of living trees, understory fires and their effects are not as easily identifiable from space as deforestation fires. Here we analyze satellite remote sensing products for CO and fire to investigate differences between deforestation fires and understory fires in the Amazon Basin under varying climatic conditions. The MOPITT (Measurements Of Pollution In The Troposphere) instrument on board NASA's Terra satellite has been measuring tropospheric CO since 2000, providing the longest global CO record to date. IASI (the Infrared Atmospheric Sounding Interferometer) A and B are two instruments on board METOP-A and -B, respectively, measuring, among others, CO since 2006 and 2012. MODIS (the Moderate Resolution Imaging Spectroradiometer) instruments on board NASA's Terra and Aqua satellites provide, among other products, a daily record of fires and their effects since 2000 and 2002, respectively. The temporal extent of all these datasets allows for the detailed analysis of drought versus non-drought years. Initial results indicate that MOPITT CO emissions during the dry season peaked in 2005, 2007, and 2010. Those were draught years and coincide with peaks in area affected by understory fires.
2000-09-14
KENNEDY SPACE CENTER, FLA. -- During training exercises at Cape Canaveral Air Force Station Pad 30, firefighters with the Fire and Emergency Services at the Naval Station Mayport, Fla., turn their hoses toward the fire on the simulated aircraft.
2000-09-14
KENNEDY SPACE CENTER, FLA. -- During training exercises at Cape Canaveral Air Force Station Pad 30, firefighters with the Fire and Emergency Services at the Naval Station Mayport, Fla., turn their hoses toward the fire on the simulated aircraft.
NASA Astrophysics Data System (ADS)
Westberg, David; Soja, Amber; Stackhouse, Paul, Jr.
2010-05-01
Fire is the dominant disturbance that precipitates ecosystem change in boreal regions, and fire is largely under the control of weather and climate. Boreal systems contain the largest pool of terrestrial carbon, and Russia holds 2/3 of the global boreal forests. Fire frequency, fire severity, area burned and fire season length are predicted to increase in boreal regions under climate change scenarios. Meteorological parameters influence fire danger and fire is a catalyst for ecosystem change. Therefore to predict fire weather and ecosystem change, we must understand the factors that influence fire regimes and at what scale these are viable. Our data consists of NASA Langley Research Center (LaRC)-derived fire weather indices (FWI) and National Climatic Data Center (NCDC) surface station-derived FWI on a domain from 50°N-80°N latitude and 70°E-170°W longitude and the fire season from April through October for the years of 1999, 2002, and 2004. Both of these are calculated using the Canadian Forest Service (CFS) FWI, which is based on local noon surface-level air temperature, relative humidity, wind speed, and daily (noon-noon) rainfall. The large-scale (1°) LaRC product uses NASA Goddard Earth Observing System version 4 (GEOS-4) reanalysis and NASA Global Precipitation Climatology Project (GEOS-4/GPCP) data to calculate FWI. CFS Natural Resources Canada uses Geographic Information Systems (GIS) to interpolate NCDC station data and calculate FWI. We compare the LaRC GEOS- 4/GPCP FWI and CFS NCDC FWI based on their fraction of 1° grid boxes that contain satellite-derived fire counts and area burned to the domain total number of 1° grid boxes with a common FWI category (very low to extreme). These are separated by International Geosphere-Biosphere Programme (IGBP) 1°x1° resolution vegetation types to determine and compare fire regimes in each FWI/ecosystem class and to estimate the fraction of each of the 18 IGBP ecosystems burned, which are dependent on the FWI. On days with fire counts, the domain total of 1°x1° grid boxes with and without daily fire counts and area burned are totaled. The fraction of 1° grid boxes with fire counts and area burned to the total number of 1° grid boxes having common FWI category and vegetation type are accumulated, and a daily mean for the burning season is calculated. The mean fire counts and mean area burned plots appear to be well related. The ultimate goal of this research is to assess the viability of large-scale (1°) data to be used to assess fire weather danger and fire regimes, so these data can be confidently used to predict future fire regimes using large-scale fire weather data. Specifically, we related large-scale fire weather, area burned, and the amount of fire-induced ecosystem change. Both the LaRC and CFS FWI showed gradual linear increase in fraction of grid boxes with fire counts and area burned with increasing FWI category, with an exponential increase in the higher FWI categories in some cases, for the majority of the vegetation types. Our analysis shows a direct correlation between increased fire activity and increased FWI, independent of time or the severity of the fire season. During normal and extreme fire seasons, we noticed the fraction of fire counts and area burned per 1° grid box increased with increasing FWI rating. Given this analysis, we are confident large-scale weather and climate data, in this case from the GEOS-4 reanalysis and the GPCP data sets, can be used to accurately assess future fire potential. This increases confidence in the ability of large-scale IPCC weather and climate scenarios to predict future fire regimes in boreal regions.
The Chronotron: A Neuron That Learns to Fire Temporally Precise Spike Patterns
Florian, Răzvan V.
2012-01-01
In many cases, neurons process information carried by the precise timings of spikes. Here we show how neurons can learn to generate specific temporally precise output spikes in response to input patterns of spikes having precise timings, thus processing and memorizing information that is entirely temporally coded, both as input and as output. We introduce two new supervised learning rules for spiking neurons with temporal coding of information (chronotrons), one that provides high memory capacity (E-learning), and one that has a higher biological plausibility (I-learning). With I-learning, the neuron learns to fire the target spike trains through synaptic changes that are proportional to the synaptic currents at the timings of real and target output spikes. We study these learning rules in computer simulations where we train integrate-and-fire neurons. Both learning rules allow neurons to fire at the desired timings, with sub-millisecond precision. We show how chronotrons can learn to classify their inputs, by firing identical, temporally precise spike trains for different inputs belonging to the same class. When the input is noisy, the classification also leads to noise reduction. We compute lower bounds for the memory capacity of chronotrons and explore the influence of various parameters on chronotrons' performance. The chronotrons can model neurons that encode information in the time of the first spike relative to the onset of salient stimuli or neurons in oscillatory networks that encode information in the phases of spikes relative to the background oscillation. Our results show that firing one spike per cycle optimizes memory capacity in neurons encoding information in the phase of firing relative to a background rhythm. PMID:22879876
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loflin, Leonard
Through this grant, the U.S. Department of Energy (DOE) will review several functional areas within a nuclear power plant, including fire protection, operations and operations support, refueling, training, procurement, maintenance, site engineering, and others. Several functional areas need to be examined since there appears to be no single staffing area or approach that alone has the potential for significant staff optimization at new nuclear power plants. Several of the functional areas will require a review of technology options such as automation, remote monitoring, fleet wide monitoring, new and specialized instrumentation, human factors engineering, risk informed analysis and PRAs, component andmore » system condition monitoring and reporting, just in time training, electronic and automated procedures, electronic tools for configuration management and license and design basis information, etc., that may be applied to support optimization. Additionally, the project will require a review key regulatory issues that affect staffing and could be optimized with additional technology input. Opportunities to further optimize staffing levels and staffing functions by selection of design attributes of physical systems and structures need also be identified. A goal of this project is to develop a prioritized assessment of the functional areas, and R&D actions needed for those functional areas, to provide the best optimization« less
Stankov Jovanovic, V P; Ilic, M D; Markovic, M S; Mitic, V D; Nikolic Mandic, S D; Stojanovic, G S
2011-09-01
Fire has been considered as an improving factor in soil quality, but only if it is controlled. Severe wild fire occurred in the summer 2007 on the Vidlic Mountain (Serbia) overspreading a huge area of meadows and forests. Main soil characteristics and content of heavy metals (Cu, Pb, Cd, Zn) in different fractions obtained after sequential extraction of soil from post-fire areas and from fire non disturbed areas were studied. In four plant species of Lamiaceae family (Ajuga genevensis L., Lamium galeobdolon (L.) L., Teucrium chamaedrys L., Acinos alpinus (L.) Moench.), that grow in typical habitats of the mountain, distribution of heavy metals in aerial parts and roots was investigated too. For all samples from post-fire area cation exchange capacity and soil organic matter content are increased while rH is decreased. Fire caused slightly increased bioavailability of the observed metals but more significant rise happened in metal amounts bound to oxides and organics. The plants showed variable behavior. T. chamaedrys collected on the post-fire area contained elevated concentrations of all analyzed metals. A. alpinus showed higher phytoaccumulation for Zn and Cd, while the other two plant species for Pb and Cd in the post-fire areas. Copyright © 2011 Elsevier Ltd. All rights reserved.
Effect of feature-selective attention on neuronal responses in macaque area MT
Chen, X.; Hoffmann, K.-P.; Albright, T. D.
2012-01-01
Attention influences visual processing in striate and extrastriate cortex, which has been extensively studied for spatial-, object-, and feature-based attention. Most studies exploring neural signatures of feature-based attention have trained animals to attend to an object identified by a certain feature and ignore objects/displays identified by a different feature. Little is known about the effects of feature-selective attention, where subjects attend to one stimulus feature domain (e.g., color) of an object while features from different domains (e.g., direction of motion) of the same object are ignored. To study this type of feature-selective attention in area MT in the middle temporal sulcus, we trained macaque monkeys to either attend to and report the direction of motion of a moving sine wave grating (a feature for which MT neurons display strong selectivity) or attend to and report its color (a feature for which MT neurons have very limited selectivity). We hypothesized that neurons would upregulate their firing rate during attend-direction conditions compared with attend-color conditions. We found that feature-selective attention significantly affected 22% of MT neurons. Contrary to our hypothesis, these neurons did not necessarily increase firing rate when animals attended to direction of motion but fell into one of two classes. In one class, attention to color increased the gain of stimulus-induced responses compared with attend-direction conditions. The other class displayed the opposite effects. Feature-selective activity modulations occurred earlier in neurons modulated by attention to color compared with neurons modulated by attention to motion direction. Thus feature-selective attention influences neuronal processing in macaque area MT but often exhibited a mismatch between the preferred stimulus dimension (direction of motion) and the preferred attention dimension (attention to color). PMID:22170961
Effect of feature-selective attention on neuronal responses in macaque area MT.
Chen, X; Hoffmann, K-P; Albright, T D; Thiele, A
2012-03-01
Attention influences visual processing in striate and extrastriate cortex, which has been extensively studied for spatial-, object-, and feature-based attention. Most studies exploring neural signatures of feature-based attention have trained animals to attend to an object identified by a certain feature and ignore objects/displays identified by a different feature. Little is known about the effects of feature-selective attention, where subjects attend to one stimulus feature domain (e.g., color) of an object while features from different domains (e.g., direction of motion) of the same object are ignored. To study this type of feature-selective attention in area MT in the middle temporal sulcus, we trained macaque monkeys to either attend to and report the direction of motion of a moving sine wave grating (a feature for which MT neurons display strong selectivity) or attend to and report its color (a feature for which MT neurons have very limited selectivity). We hypothesized that neurons would upregulate their firing rate during attend-direction conditions compared with attend-color conditions. We found that feature-selective attention significantly affected 22% of MT neurons. Contrary to our hypothesis, these neurons did not necessarily increase firing rate when animals attended to direction of motion but fell into one of two classes. In one class, attention to color increased the gain of stimulus-induced responses compared with attend-direction conditions. The other class displayed the opposite effects. Feature-selective activity modulations occurred earlier in neurons modulated by attention to color compared with neurons modulated by attention to motion direction. Thus feature-selective attention influences neuronal processing in macaque area MT but often exhibited a mismatch between the preferred stimulus dimension (direction of motion) and the preferred attention dimension (attention to color).
Atwood, Elizabeth C.; Englhart, Sandra; Lorenz, Eckehard; Halle, Winfried; Wiedemann, Werner; Siegert, Florian
2016-01-01
Vast and disastrous fires occurred on Borneo during the 2015 dry season, pushing Indonesia into the top five carbon emitting countries. The region was affected by a very strong El Niño-Southern Oscillation (ENSO) climate phenomenon, on par with the last severe event in 1997/98. Fire dynamics in Central Kalimantan were investigated using an innovative sensor offering higher sensitivity to a wider range of fire intensities at a finer spatial resolution (160 m) than heretofore available. The sensor is onboard the TET-1 satellite, part of the German Aerospace Center (DLR) FireBird mission. TET-1 images (acquired every 2–3 days) from the middle infrared were used to detect fires continuously burning for almost three weeks in the protected peatlands of Sebangau National Park as well as surrounding areas with active logging and oil palm concessions. TET-1 detection capabilities were compared with MODIS active fire detection and Landsat burned area algorithms. Fire dynamics, including fire front propagation speed and area burned, were investigated. We show that TET-1 has improved detection capabilities over MODIS in monitoring low-intensity peatland fire fronts through thick smoke and haze. Analysis of fire dynamics revealed that the largest burned areas resulted from fire front lines started from multiple locations, and the highest propagation speeds were in excess of 500 m/day (all over peat > 2m deep). Fires were found to occur most often in concessions that contained drainage infrastructure but were not cleared prior to the fire season. Benefits of implementing this sensor system to improve current fire management techniques are discussed. Near real-time fire detection together with enhanced fire behavior monitoring capabilities would not only improve firefighting efforts, but also benefit analysis of fire impact on tropical peatlands, greenhouse gas emission estimations as well as mitigation measures to reduce severe fire events in the future. PMID:27486664
Atwood, Elizabeth C; Englhart, Sandra; Lorenz, Eckehard; Halle, Winfried; Wiedemann, Werner; Siegert, Florian
2016-01-01
Vast and disastrous fires occurred on Borneo during the 2015 dry season, pushing Indonesia into the top five carbon emitting countries. The region was affected by a very strong El Niño-Southern Oscillation (ENSO) climate phenomenon, on par with the last severe event in 1997/98. Fire dynamics in Central Kalimantan were investigated using an innovative sensor offering higher sensitivity to a wider range of fire intensities at a finer spatial resolution (160 m) than heretofore available. The sensor is onboard the TET-1 satellite, part of the German Aerospace Center (DLR) FireBird mission. TET-1 images (acquired every 2-3 days) from the middle infrared were used to detect fires continuously burning for almost three weeks in the protected peatlands of Sebangau National Park as well as surrounding areas with active logging and oil palm concessions. TET-1 detection capabilities were compared with MODIS active fire detection and Landsat burned area algorithms. Fire dynamics, including fire front propagation speed and area burned, were investigated. We show that TET-1 has improved detection capabilities over MODIS in monitoring low-intensity peatland fire fronts through thick smoke and haze. Analysis of fire dynamics revealed that the largest burned areas resulted from fire front lines started from multiple locations, and the highest propagation speeds were in excess of 500 m/day (all over peat > 2m deep). Fires were found to occur most often in concessions that contained drainage infrastructure but were not cleared prior to the fire season. Benefits of implementing this sensor system to improve current fire management techniques are discussed. Near real-time fire detection together with enhanced fire behavior monitoring capabilities would not only improve firefighting efforts, but also benefit analysis of fire impact on tropical peatlands, greenhouse gas emission estimations as well as mitigation measures to reduce severe fire events in the future.
Teodoro, Grazielle Sales; van den Berg, Eduardo; Arruda, Rafael
2013-01-01
Mistletoes are aerial hemiparasitic plants which occupy patches of favorable habitat (host trees) surrounded by unfavorable habitat and may be possibly modeled as a metapopulation. A metapopulation is defined as a subdivided population that persists due to the balance between colonization and extinction in discrete habitat patches. Our aim was to evaluate the dynamics of the mistletoe Psittacanthus robustus and its host Vochysia thyrsoidea in three Brazilian savanna areas using a metapopulation approach. We also evaluated how the differences in terms of fire occurrence affected the dynamic of those populations (two areas burned during the study and one was fire protected). We monitored the populations at six-month intervals. P. robustus population structure and dynamics met the expected criteria for a metapopulation: i) the suitable habitats for the mistletoe occur in discrete patches; (ii) local populations went extinct during the study and (iii) colonization of previously non-occupied patches occurred. The ratio of occupied patches decreased in all areas with time. Local mistletoe populations went extinct due to two different causes: patch extinction in area with no fire and fire killing in the burned areas. In a burned area, the largest decrease of occupied patch ratios occurred due to a fire event that killed the parasites without, however, killing the host trees. The greatest mortality of V. thyrsoidea occurred in the area without fire. In this area, all the dead trees supported mistletoe individuals and no mortality was observed for parasite-free trees. Because P. robustus is a fire sensitive species and V. thyrsoidea is fire tolerant, P. robustus seems to increase host mortality, but its effect is lessened by periodic burning that reduces the parasite loads. PMID:23776554
NASA Astrophysics Data System (ADS)
Jalilzadeh Shadlouei, A.; Delavar, M. R.
2013-09-01
There are many vegetation in Iran. This is because of extent of Iran and its width. One of these vegetation is forest vegetation most prevalent in Northern provinces named Guilan, Mazandaran, Gulestan, Ardebil as well as East Azerbaijan. These forests are always threatened by natural forest fires so much so that there have been reports of tens of fires in recent years. Forest fires are one of the major environmental as well as economic, social and security concerns in the world causing much damages. According to climatology, forest fires are one of the important factors in the formation and dispersion of vegetation. Also, regarding the environment, forest fires cause the emission of considerable amounts of greenhouse gases, smoke and dust into the atmosphere which in turn causes the earth temperature to rise up and are unhealthy to humans, animals and vegetation. In agriculture droughts are the usual side effects of these fires. The causes of forest fires could be categorized as either Human or Natural Causes. Naturally, it is impossible to completely contain forest fires; however, areas with high potentials of fire could be designated and analysed to decrease the risk of fires. The zoning of forest fire potential is a multi-criteria problem always accompanied by inherent uncertainty like other multi-criteria problems. So far, various methods and algorithm for zoning hazardous areas via Remote Sensing (RS) and Geospatial Information System (GIS) have been offered. This paper aims at zoning forest fire potential of Gulestan Province of Iran forests utilizing Remote Sensing, Geospatial Information System, meteorological data, MODIS images and granular computing method. Granular computing is part of granular mathematical and one way of solving multi-criteria problems such forest fire potential zoning supervised by one expert or some experts , and it offers rules for classification with the least inconsistencies. On the basis of the experts' opinion, 6 determinative criterias contributing to forest fires have been designated as follows: vegetation (NDVI), slope, aspect, temperature, humidity and proximity to roadways. By applying these variables on several tentatively selected areas and formation information tables and producing granular decision tree and extraction of rules, the zoning rules (for the areas in question) were extracted. According to them the zoning of the entire area has been conducted. The zoned areas have been classified into 5 categories: high hazard, medium hazard (high), medium hazard (low), low hazard (high), low hazard (low). According to the map, the zoning of most of the areas fall into the low hazard (high) class while the least number of areas have been classified as low hazard (low). Comparing the forest fires in these regions in 2010 with the MODIS data base for forest fires, it is concluded that areas with high hazards of forest fire have been classified with a 64 percent precision. In other word 64 percent of pixels that are in high hazard classification are classified according to MODIS data base. Using this method we obtain a good range of Perception. Manager will reduce forest fire concern using precautionary proceeding on hazardous area.
Climate, lightning ignitions, and fire severity in Yosemite National Park, California, USA
James A. Lutz; Jan W. van Wagtendonk; Andrea E. Thode; Jay D. Miller; Jerry F. Franklin
2009-01-01
Continental-scale studies of western North America have attributed recent increases in annual area burned and fire size to a warming climate, but these studies have focused on large fires and have left the issues of fire severity and ignition frequency unaddressed. Lightning ignitions, any of which could burn a large area given appropriate conditions for fire spread,...
Mapping Fire Scars in the Brazilian Cerrado Using AVHRR Imagery
NASA Technical Reports Server (NTRS)
Hlavka, C. A.; Ambrosia, V. G.; Brass, J. A.; Rezendez, A.; Alexander, S.; Guild, L. S.; Peterson, David L. (Technical Monitor)
1995-01-01
The Brazilian cerrado, or savanna, spans an area of 1,800,000 square kilometers on the great plateau of Central Brazil. Large fires covering hundreds of square kilometers, frequently occur in wildland areas of the cerrado, dominated by grasslands or grasslands mixed with shrubs and small trees, and also within area in the cerrado used for agricultural purposes, particularly for grazing. Smaller fires, typically extending over arm of a few square kilometers or less, are associated with the clewing of crops, such as dry land rice. A method for mapping fire scars and differentiating them from extensive areas of bare sod with AVHRR bands 1 (.55 -.68 micrometer) and 3 (3.5 - 3.9 micrometers) and measures of performance based on comparison with maps of fires with Landsat imagery will be presented. Methods of estimating total area burned from the AVHRR fire scar map will be discussed and related to land use and scar size.
A WSN-Based Tool for Urban and Industrial Fire-Fighting
De San Bernabe Clemente, Alberto; Dios, José Ramiro Martínez-de; Baturone, Aníbal Ollero
2012-01-01
This paper describes a WSN tool to increase safety in urban and industrial fire-fighting activities. Unlike most approaches, we assume that there is no preexisting WSN in the building, which involves interesting advantages but imposes some constraints. The system integrates the following functionalities: fire monitoring, firefighter monitoring and dynamic escape path guiding. It also includes a robust localization method that employs RSSI-range models dynamically trained to cope with the peculiarities of the environment. The training and application stages of the method are applied simultaneously, resulting in significant adaptability. Besides simulations and laboratory tests, a prototype of the proposed system has been validated in close-to-operational conditions. PMID:23202198
A Contextual Fire Detection Algorithm for Simulated HJ-1B Imagery.
Qian, Yonggang; Yan, Guangjian; Duan, Sibo; Kong, Xiangsheng
2009-01-01
The HJ-1B satellite, which was launched on September 6, 2008, is one of the small ones placed in the constellation for disaster prediction and monitoring. HJ-1B imagery was simulated in this paper, which contains fires of various sizes and temperatures in a wide range of terrestrial biomes and climates, including RED, NIR, MIR and TIR channels. Based on the MODIS version 4 contextual algorithm and the characteristics of HJ-1B sensor, a contextual fire detection algorithm was proposed and tested using simulated HJ-1B data. It was evaluated by the probability of fire detection and false alarm as functions of fire temperature and fire area. Results indicate that when the simulated fire area is larger than 45 m(2) and the simulated fire temperature is larger than 800 K, the algorithm has a higher probability of detection. But if the simulated fire area is smaller than 10 m(2), only when the simulated fire temperature is larger than 900 K, may the fire be detected. For fire areas about 100 m(2), the proposed algorithm has a higher detection probability than that of the MODIS product. Finally, the omission and commission error were evaluated which are important factors to affect the performance of this algorithm. It has been demonstrated that HJ-1B satellite data are much sensitive to smaller and cooler fires than MODIS or AVHRR data and the improved capabilities of HJ-1B data will offer a fine opportunity for the fire detection.
Jackson, B Scott
2004-10-01
Many different types of integrate-and-fire models have been designed in order to explain how it is possible for a cortical neuron to integrate over many independent inputs while still producing highly variable spike trains. Within this context, the variability of spike trains has been almost exclusively measured using the coefficient of variation of interspike intervals. However, another important statistical property that has been found in cortical spike trains and is closely associated with their high firing variability is long-range dependence. We investigate the conditions, if any, under which such models produce output spike trains with both interspike-interval variability and long-range dependence similar to those that have previously been measured from actual cortical neurons. We first show analytically that a large class of high-variability integrate-and-fire models is incapable of producing such outputs based on the fact that their output spike trains are always mathematically equivalent to renewal processes. This class of models subsumes a majority of previously published models, including those that use excitation-inhibition balance, correlated inputs, partial reset, or nonlinear leakage to produce outputs with high variability. Next, we study integrate-and-fire models that have (nonPoissonian) renewal point process inputs instead of the Poisson point process inputs used in the preceding class of models. The confluence of our analytical and simulation results implies that the renewal-input model is capable of producing high variability and long-range dependence comparable to that seen in spike trains recorded from cortical neurons, but only if the interspike intervals of the inputs have infinite variance, a physiologically unrealistic condition. Finally, we suggest a new integrate-and-fire model that does not suffer any of the previously mentioned shortcomings. By analyzing simulation results for this model, we show that it is capable of producing output spike trains with interspike-interval variability and long-range dependence that match empirical data from cortical spike trains. This model is similar to the other models in this study, except that its inputs are fractional-gaussian-noise-driven Poisson processes rather than renewal point processes. In addition to this model's success in producing realistic output spike trains, its inputs have long-range dependence similar to that found in most subcortical neurons in sensory pathways, including the inputs to cortex. Analysis of output spike trains from simulations of this model also shows that a tight balance between the amounts of excitation and inhibition at the inputs to cortical neurons is not necessary for high interspike-interval variability at their outputs. Furthermore, in our analysis of this model, we show that the superposition of many fractional-gaussian-noise-driven Poisson processes does not approximate a Poisson process, which challenges the common assumption that the total effect of a large number of inputs on a neuron is well represented by a Poisson process.
NASA Astrophysics Data System (ADS)
Ager, Alan; Barros, Ana; Day, Michelle; Preisler, Haiganoush; Evers, Cody
2015-04-01
We develop the idea of risk transmission from large wildfires and apply network analyses to understand its importance within the 3.2 million ha Fire-People-Forest study area in central Oregon, US. Historic wildfires within the study and elsewhere in the western US frequently burn over long distances (e.g., 20-50 km) through highly fragmented landscapes with respect to ownership, fuels, management intensity, population density, and ecological conditions. The collective arrangement of fuel loadings in concert with weather and suppression efforts ultimately determines containment and the resulting fire perimeter. While spatial interactions among land parcels in terms of fire spread and intensity have been frequently noted by fire managers, quantifying risk and exposure transmission is not well understood. In this paper we used simulation modeling to quantify wildfire transmission and built a transmission network among and within land owners and communities within the study area. The results suggested that 84% of the predicted area burned within the 25 communities in the study area was from simulated fires that ignited on federal lands. The wildland urban interface surrounding the communities was predicted to burn at a rate of 2 % per year, with 57% of the area burned from fires ignited on federal lands. The node degree for communities indicated that simulated fires originated on about 6 different landowners. Network analyses in general revealed independent variation in transmitted fire among landowners in terms of both node degree (diversity of landowners exchanging fire) and transmitted fire, indicating that both the spatial grain of land ownership and wildfire topology contribute to transmission among land parcels. We discuss how network analyses of wildfire transmission can inform fire management goals for creating fire adapted communities, conserving biodiversity, and resolving competing demands for fire-prone ecosystem services. We also discuss how biophysical fire networks can potentially be coupled with social fire networks to improve wildfire mitigation planning.
The 1977 tundra fire in the Kokolik River area of Alaska
NASA Technical Reports Server (NTRS)
1981-01-01
Presumably caused by lightning, a large fire occurred due east of Point Lay several kilometers southwest of the Kokolik River, the farthest north a fire was ever fought by Bureau of Land Management personnel in Alaska. The progress and area extent of the fire were determined by analysis of LANDSAT MSS band 5 and 7 imagery. Low altitude observations from helicopter showed the fire burned a range of vegetation and relief types which included low polygonized and upland tussock tundras. The burned area appeared wetter on the surface than the unburned area, due to a lack of moisture absorbing organic matter and the possible release of moisture from the deeper thawed zone. Suggestions for future investigations of the effects of fire on tundra and permafrost terrains are discussed.
Final Environmental Assessment For the Construction and Operation of a Fire Training Facility
2010-04-29
practice drafting (i.e., water uptake through hoses ) operations during live fires. The proposed drafting pit would also allow the department to...FTF to allow the Clear FD to practice drafting (i.e., water uptake through hoses ) operations during live fires. The proposed drafting pit would also...respirators, etc.), but trucks, hoses , and other large equipment would need to be supplied by the host fire department (so as not to leave Clear AFS
Automated Wildfire Detection Through Artificial Neural Networks
NASA Technical Reports Server (NTRS)
Miller, Jerry; Borne, Kirk; Thomas, Brian; Huang, Zhenping; Chi, Yuechen
2005-01-01
Wildfires have a profound impact upon the biosphere and our society in general. They cause loss of life, destruction of personal property and natural resources and alter the chemistry of the atmosphere. In response to the concern over the consequences of wildland fire and to support the fire management community, the National Oceanic and Atmospheric Administration (NOAA), National Environmental Satellite, Data and Information Service (NESDIS) located in Camp Springs, Maryland gradually developed an operational system to routinely monitor wildland fire by satellite observations. The Hazard Mapping System, as it is known today, allows a team of trained fire analysts to examine and integrate, on a daily basis, remote sensing data from Geostationary Operational Environmental Satellite (GOES), Advanced Very High Resolution Radiometer (AVHRR) and Moderate Resolution Imaging Spectroradiometer (MODIS) satellite sensors and generate a 24 hour fire product for the conterminous United States. Although assisted by automated fire detection algorithms, N O M has not been able to eliminate the human element from their fire detection procedures. As a consequence, the manually intensive effort has prevented NOAA from transitioning to a global fire product as urged particularly by climate modelers. NASA at Goddard Space Flight Center in Greenbelt, Maryland is helping N O M more fully automate the Hazard Mapping System by training neural networks to mimic the decision-making process of the frre analyst team as well as the automated algorithms.
NASA Astrophysics Data System (ADS)
Li, Tao; Xie, Wei
2017-04-01
The spiral tunnel arises as a new form of tunnel, with great differences in fire development pattern when compared with traditional straight line tunnel, this paper takes method of numerical simulation, based on computation fluid dynamics theory and fire-turbulence numerical simulation theory, establishing a full-scale spiral tunnel model, and applies CFX simulation software to research full-scale spiral tunnel fire and its ventilation condition. The results indicate that with increasing tunnel slope, high temperature area gradually extends to downstream area, high temperature mainly distributes near fire source area, and symmetrically distributes among the fire center point; With increasing tunnel slope, the highest temperature underneath tunnel arch rises first followed by a downward trend and then rising again, which strengthens chimney effect, and promotes more fresh cold air flow into the tunnel, suppressing fire smoke backflow and simultaneously accelerating fire smoke spread to downstream area; Fire plume presents vertical slender shape with 1% or 3% tunnel slope, and burning flame hits tunnel arch and then extending all around into the ceiling jet flow, when tunnel slope increases to 5% or 7%, fire plume cross section grows bigger and wider with unstable burning flame swaying in all directions, integrally incline to fire downstream.
Remote sensing techniques in monitoring areas affected by forest fire
NASA Astrophysics Data System (ADS)
Karagianni, Aikaterini Ch.; Lazaridou, Maria A.
2017-09-01
Forest fire is a part of nature playing a key role in shaping ecosystems. However, fire's environmental impacts can be significant, affecting wildlife habitat and timber, human settlements, man-made technical constructions and various networks (road, power networks) and polluting the air with emissions harmful to human health. Furthermore, fire's effect on the landscape may be long-lasting. Monitoring the development of a fire occurs as an important aspect at the management of natural hazards in general. Among the used methods for monitoring, satellite data and remote sensing techniques can be proven of particular importance. Satellite remote sensing offers a useful tool for forest fire detection, monitoring, management and damage assessment. Especially for fire scars detection and monitoring, satellite data derived from Landsat 8 can be a useful research tool. This paper includes critical considerations of the above and concerns in particular an example of the Greek area (Thasos Island). This specific area was hit by fires several times in the past and recently as well (September 2016). Landsat 8 satellite data are being used (pre and post fire imagery) and digital image processing techniques are applied (enhancement techniques, calculation of various indices) for fire scars detection. Visual interpretation of the example area affected by the fires is also being done, contributing to the overall study.
C. Alina Cansler; Donald. McKenzie
2014-01-01
Warmer and drier climate over the past few decades has brought larger fire sizes and increased annual area burned in forested ecosystems of western North America, and continued increases in annual area burned are expected due to climate change. As warming continues, fires may also increase in severity and produce larger contiguous patches of severely burned areas. We...
Site investigation for 125th fighter interceptor group Florida Air National Guard
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-03-01
A two-step Site Investigation (SI) was conducted to evaluate the nature and extent of environmental contamination that might have resulted from past activities at eight disposal/spill sites at the 125th Fighter Interceptor Group, Florida Air National Guard (FANG) in Jacksonville, Florida. The sites included in the SI are shown on the location map in Figure ES-i and briefly described below: Oil/water separator (OWS) inlets along the aircraft parking apron; Subsurface of aircraft parking apron; Fire training areas, separated for clarity into Site 3E for the east area and Site 3W for the west area; OWS at the Hush House; OWSmore » at the Vehicle Maintenance Building; Area outside the Munitions Building; Trim pad for aircraft run-up; OWS at the Wash Rack.« less
NASA Technical Reports Server (NTRS)
Kaminski, Charles F., Jr.
1999-01-01
A small project to compile remote sensing and in-site data to review the processes leading to the May 1998 Mexican/Central American fires was undertaken. A web page based on this project was assembled. The second project initiated involved an interactive and on-line program that will replace the paper version of the Earth Observations Preflight Training Manual. Technical support was provided to Prof. Marvin Glasser as needed.
Integral Color Anodizing of Aluminum Alloy 7075-T6 Upper Receivers of the M16A1 Rifle
1981-06-01
and control upper receivers were carried, fired, and maintained by soldiers in the field undergoing basic and advanced Infantry training and by other...soldiers undergoing Ranger training . The test and control items were subjected to typical field usage conditions involving rough handhng, firing...ICA hardcoat treatment will provide a longer inservice life for the M16A1 rifle receivers than will the low- temperature hardcoat process. 12
Fire-probability maps for the Brazilian Amazonia
NASA Astrophysics Data System (ADS)
Cardoso, M.; Nobre, C.; Obregon, G.; Sampaio, G.
2009-04-01
Most fires in Amazonia result from the combination between climate and land-use factors. They occur mainly in the dry season and are used as an inexpensive tool for land clearing and management. However, their unintended consequences are of important concern. Fire emissions are the most important sources of greenhouse gases and aerosols in the region, accidental fires are a major threat to protected areas, and frequent fires may lead to permanent conversion of forest areas into savannas. Fire-activity models have thus become important tools for environmental analyses in Amazonia. They are used, for example, in warning systems for monitoring the risk of burnings in protected areas, to improve the description of biogeochemical cycles and vegetation composition in ecosystem models, and to help estimate the long-term potential for savannas in biome models. Previous modeling studies for the whole region were produced in units of satellite fire pixels, which complicate their direct use for environmental applications. By reinterpreting remote-sensing based data using a statistical approach, we were able to calibrate models for the whole region in units of probability, or chance of fires to occur. The application of these models for years 2005 and 2006 provided maps of fire potential at 3-month and 0.25-deg resolution as a function of precipitation and distance from main roads. In both years, the performance of the resulting maps was better for the period July-September. During these months, most of satellite-based fire observations were located in areas with relatively high chance of fire, as determined by the modeled probability maps. In addition to reproduce reasonably well the areas presenting maximum fire activity as detected by remote sensing, the new results in units of probability are easier to apply than previous estimates from fire-pixel models.
Fire-probability maps for the Brazilian Amazonia
NASA Astrophysics Data System (ADS)
Cardoso, Manoel; Sampaio, Gilvan; Obregon, Guillermo; Nobre, Carlos
2010-05-01
Most fires in Amazonia result from the combination between climate and land-use factors. They occur mainly in the dry season and are used as an inexpensive tool for land clearing and management. However, their unintended consequences are of important concern. Fire emissions are the most important sources of greenhouse gases and aerosols in the region, accidental fires are a major threat to protected areas, and frequent fires may lead to permanent conversion of forest areas into savannas. Fire-activity models have thus become important tools for environmental analyses in Amazonia. They are used, for example, in warning systems for monitoring the risk of burnings in protected areas, to improve the description of biogeochemical cycles and vegetation composition in ecosystem models, and to help estimate the long-term potential for savannas in biome models. Previous modeling studies for the whole region were produced in units of satellite fire pixels, which complicate their direct use for environmental applications. By reinterpreting remote-sensing based data using a statistical approach, we were able to calibrate models for the whole region in units of probability, or chance of fires to occur. The application of these models for years 2005 and 2006 provided maps of fire potential at 3-month and 0.25-deg resolution as a function of precipitation and distance from main roads. In both years, the performance of the resulting maps was better for the period July-September. During these months, most of satellite-based fire observations were located in areas with relatively high chance of fire, as determined by the modeled probability maps. In addition to reproduce reasonably well the areas presenting maximum fire activity as detected by remote sensing, the new results in units of probability are easier to apply than previous estimates from fire-pixel models.
Nolte, Christoph; Agrawal, Arun
2013-02-01
Management-effectiveness scores are used widely by donors and implementers of conservation projects to prioritize, track, and evaluate investments in protected areas. However, there is little evidence that these scores actually reflect the capacity of protected areas to deliver conservation outcomes. We examined the relation between indicators of management effectiveness in protected areas and the effectiveness of protected areas in reducing fire occurrence in the Amazon rainforest. We used data collected with the Management Effectiveness Tracking Tool (METT) scorecard, adopted by some of the world's largest conservation organizations to track management characteristics believed to be crucial for protected-area effectiveness. We used the occurrence of forest fires from 2000 through 2010 as a measure of the effect of protected areas on undesired land-cover change in the Amazon basin. We used matching to compare the estimated effect of protected areas with low versus high METT scores on fire occurrence. We also estimated effects of individual protected areas on fire occurrence and explored the relation between these effects and METT scores. The relations between METT scores and effects of protected areas on fire occurrence were weak. Protected areas with higher METT scores in 2005 did not seem to have performed better than protected areas with lower METT scores at reducing fire occurrence over the last 10 years. Further research into the relations between management-effectiveness indicators and conservation outcomes in protected areas seems necessary, and our results show that the careful application of matching methods can be a suitable method for that purpose. ©2012 Society for Conservation Biology.
Interactions among wildland fires in a long-established Sierra Nevada natural fire area
Collins, B.M.; Miller, J.D.; Thode, A.E.; Kelly, M.; van Wagtendonk, J.W.; Stephens, S.L.
2009-01-01
We investigate interactions between successive naturally occurring fires, and assess to what extent the environments in which fires burn influence these interactions. Using mapped fire perimeters and satellite-based estimates of post-fire effects (referred to hereafter as fire severity) for 19 fires burning relatively freely over a 31-year period, we demonstrate that fire as a landscape process can exhibit self-limiting characteristics in an upper elevation Sierra Nevada mixed conifer forest. We use the term 'self-limiting' to refer to recurring fire as a process over time (that is, fire regime) consuming fuel and ultimately constraining the spatial extent and lessening fire-induced effects of subsequent fires. When the amount of time between successive adjacent fires is under 9 years, and when fire weather is not extreme (burning index <34.9), the probability of the latter fire burning into the previous fire area is extremely low. Analysis of fire severity data by 10-year periods revealed a fair degree of stability in the proportion of area burned among fire severity classes (unchanged, low, moderate, high). This is in contrast to a recent study demonstrating increasing high-severity burning throughout the Sierra Nevada from 1984 to 2006, which suggests freely burning fires over time in upper elevation Sierra Nevada mixed conifer forests can regulate fire-induced effects across the landscape. This information can help managers better anticipate short- and long-term effects of allowing naturally ignited fires to burn, and ultimately, improve their ability to implement Wildland Fire Use programs in similar forest types. ?? 2008 Springer Science+Business Media, LLC.
Geoffrey J. Cary; Ian D. Davies; Ross A. Bradstock; Robert E. Keane; Mike D. Flannigan
2017-01-01
Context: Wildland fire intensity influences natural communities, soil properties, erosion, and sequestered carbon. Measuring effectiveness of fuel treatment for reducing area of higher intensity unplanned fire is argued to be more meaningful than determining effect on total unplanned area burned. Objectives...
Sharon M. Hood; Donald Long; Melanie Miller; Kevin C. Ryan
2007-01-01
Many areas throughout the United States are facing the triple threat of increasing fire severity, residential growth in areas prone to wildland fire, and suppression costs and losses. In addition, substantial changes are occurring in the way we plan and implement management on federal lands relative to use of wildland fire, prescribed fire, and mechanical fuel...
Reconstructing grassland fire history using sedimentary charcoal: Considering count, size and shape.
Leys, Berangere A; Commerford, Julie L; McLauchlan, Kendra K
2017-01-01
Fire is a key Earth system process, with 80% of annual fire activity taking place in grassland areas. However, past fire regimes in grassland systems have been difficult to quantify due to challenges in interpreting the charcoal signal in depositional environments. To improve reconstructions of grassland fire regimes, it is essential to assess two key traits: (1) charcoal count, and (2) charcoal shape. In this study, we quantified the number of charcoal pieces in 51 sediment samples of ponds in the Great Plains and tested its relevance as a proxy for the fire regime by examining 13 potential factors influencing charcoal count, including various fire regime components (e.g. the fire frequency, the area burned, and the fire season), vegetation cover and pollen assemblages, and climate variables. We also quantified the width to length (W:L) ratio of charcoal particles, to assess its utility as a proxy of fuel types in grassland environments by direct comparison with vegetation cover and pollen assemblages. Our first conclusion is that charcoal particles produced by grassland fires are smaller than those produced by forest fires. Thus, a mesh size of 120μm as used in forested environments is too large for grassland ecosystems. We recommend counting all charcoal particles over 60μm in grasslands and mixed grass-forest environments to increase the number of samples with useful data. Second, a W:L ratio of 0.5 or smaller appears to be an indicator for fuel types, when vegetation surrounding the site is before composed of at least 40% grassland vegetation. Third, the area burned within 1060m of the depositional environments explained both the count and the area of charcoal particles. Therefore, changes in charcoal count or charcoal area through time indicate a change in area burned. The fire regimes of grassland systems, including both human and climatic influences on fire behavior, can be characterized by long-term charcoal records.
Reconstructing grassland fire history using sedimentary charcoal: Considering count, size and shape
Leys, Berangere A.; Commerford, Julie L.; McLauchlan, Kendra K.
2017-01-01
Fire is a key Earth system process, with 80% of annual fire activity taking place in grassland areas. However, past fire regimes in grassland systems have been difficult to quantify due to challenges in interpreting the charcoal signal in depositional environments. To improve reconstructions of grassland fire regimes, it is essential to assess two key traits: (1) charcoal count, and (2) charcoal shape. In this study, we quantified the number of charcoal pieces in 51 sediment samples of ponds in the Great Plains and tested its relevance as a proxy for the fire regime by examining 13 potential factors influencing charcoal count, including various fire regime components (e.g. the fire frequency, the area burned, and the fire season), vegetation cover and pollen assemblages, and climate variables. We also quantified the width to length (W:L) ratio of charcoal particles, to assess its utility as a proxy of fuel types in grassland environments by direct comparison with vegetation cover and pollen assemblages. Our first conclusion is that charcoal particles produced by grassland fires are smaller than those produced by forest fires. Thus, a mesh size of 120μm as used in forested environments is too large for grassland ecosystems. We recommend counting all charcoal particles over 60μm in grasslands and mixed grass-forest environments to increase the number of samples with useful data. Second, a W:L ratio of 0.5 or smaller appears to be an indicator for fuel types, when vegetation surrounding the site is before composed of at least 40% grassland vegetation. Third, the area burned within 1060m of the depositional environments explained both the count and the area of charcoal particles. Therefore, changes in charcoal count or charcoal area through time indicate a change in area burned. The fire regimes of grassland systems, including both human and climatic influences on fire behavior, can be characterized by long-term charcoal records. PMID:28448597
Special report. Revising your fire safety plans.
1993-12-01
Every hospital has a fire safety plan, although some fail to update their plans when circumstances change, such as when the facility is refurbished or new fire protection equipment is added, or when new wings bring in additional patients and staff. Others may fail to develop new education programs to heighten staff awareness of what is expected of them during a fire and to train employees to meet those expectations. In this report, we'll examine the new fire safety plans at two Massachusetts hospitals and the revisions they made to address these issues. We'll offer suggestions for effectively evaluating and revising your own fire safety plans.
Water Supply. Fire Service Certification Series. Unit FSCS-FF-9-80.
ERIC Educational Resources Information Center
Pribyl, Paul F.
This training unit on water supply is part of a 17-unit course package written to aid instructors in the development, teaching, and evaluation of fire fighters in the Wisconsin Fire Service Certification Series. The purpose stated for the 4-hour unit is to assist the firefighter in the proper use of water supplies and the understanding of the…
Fire Play: ICCARUS--Intelligent Command and Control, Acquisition and Review Using Simulation
ERIC Educational Resources Information Center
Powell, James; Wright, Theo; Newland, Paul; Creed, Chris; Logan, Brian
2008-01-01
Is it possible to educate a fire officer to deal intelligently with the command and control of a major fire event he will never have experienced? The authors of this paper believe there is, and present here just one solution to this training challenge. It involves the development of an intelligent simulation based upon computer managed interactive…
Boosting fire drill participation in hospital settings.
Prosper, Darryl
2015-01-01
In a health system with over 100 sites in a geographically dispersed region, boosting fire drill participation to meet government requirements, according to the author, is a constant effort, both to achieve and to maintain. In this article, he describes a comprehensive approach that entails engagement of executive, site committees and local fire authorities, as well as comprehensive training and awareness campaigns.
Emissions from Forest Fires near Mexico City
NASA Technical Reports Server (NTRS)
Yokelson, R.; Urbanski, S.; Atlas, E.; Toohey, D.; Alvarado, E.; Crounse, J.; Wennberg, P.; Fisher, M.; Wold, C.; Campos, T.;
2007-01-01
The emissions of NOx (defined as NO (nitric oxide) + NO2 (nitrogen dioxide)) and hydrogen cyanide (HCN), per unit amount of fuel burned, from fires in the pine forests that dominate the mountains surrounding Mexico City (MC) are about 2 times higher than normally observed for forest burning. The ammonia (NH3) emissions are about average for forest burning. The upper limit for the mass ratio of NOX to volatile organic compounds (VOC) for these MC-area mountain fires was approximately 0.38, which is similar to the NOx/VOC ratio in the MC urban area emissions inventory of 0.34, but much larger than the NOx/VOC ratio for tropical forest fires in Brazil (approximately 0.068). The nitrogen enrichment in the fire emissions may be due to deposition of nitrogen-containing pollutants in the outflow from the MC urban area. This effect may occur worldwide wherever biomass burning coexists with large urban areas (e.g. the tropics, southeastern US, Los Angeles Basin). The molar emission ratio of HCN to carbon monoxide (CO) for the mountain fires was 0.012 +/- 0.007, which is 2-9 times higher than widely used literature values for biomass burning. The ambient molar ratio HCN/CO in the MC-area outflow is about 0.003 +/- 0.0003. Thus, if only mountain fires emit significant amounts of HCN, these fires may be contributing about 25% of the CO production in the MCarea (approximately 98-100 W and 19-20 N). Comparing the PM10/CO and PM2.5/CO mass ratios in the MC Metropolitan Area emission inventory (0.01 15 and 0.0037) to the PM1/CO mass ratio for the mountain fires (0.133) then suggests that these fires could produce as much as approximately 79-92% of the primary fine particle mass generated in the MC-area. Considering both the uncertainty in the HCN/CO ratios and secondary aerosol formation in the urban and fire emissions implies that about 50 +/- 30% of the "aged" fine particle mass in the March 2006 MC-area outflow could be from these fires.
NASA Astrophysics Data System (ADS)
Westerling, A. L.; Fites, J. A.; Keyser, A.
2015-12-01
Annual wildfire burned area in federally managed Sierra Nevada forests has increased by more than 10,000 ha per decade since the early 1970s. At the same time, recent years have seen some extremely large fires compared to the historical record, with significant areas of moderate to high severity fire (e.g., McNally 2002, Rim 2013, King 2014 fires). Changes to fuels and fire regimes due to fire suppression and land use, as well as warming temperatures and the occurrence of drought, are thought to be significant factors contributing to increased risks of large, severe fires in Sierra Nevada forests. Over 70% of the vegetated area in federally managed forests in the Sierra Nevada is classified as having altered fuels and fire regimes, while average annual temperature in the Sierra Nevada has been above the long term mean for all but four years in the past two decades. As climate is expected to continue warming for decades to come, we explored fuels management scenarios as the primary tools available to modify risks of large, severe wildfires. We developed experimental statistical models of fire occurrence, fire size, and high severity burned area, to explore the interaction between climate and altered fuels conditions. These models were applied to historical climate conditions, a sample of future climate projections, and to both current fuels conditions and a range of scenarios for fuels treatments. Emissions from wildfires were estimated using the Fire Inventory from the National Center for Atmospheric Research. Our models project that average annual burned area in the Sierra Nevada will more than double by mid-century. Similarly, particulate and other pollution emissions from Sierra Nevada wildfires are projected to more than double, even if future fire severity does not change. Fuels treatment scenarios significantly reduced simulated future burned area and emissions below untreated projections. High severity burned area responded to both climate and fuels treatments. A sensitivity analysis indicated that in areas where the fraction of highly altered fuels is high, successfully restoring fuels to prehistoric conditions could more than compensate for expected climate change effects on fire severity by mid-century.
Matthew P. Thompson; Patrick Freeborn; Jon D. Rieck; Dave Calkin; Julie W. Gilbertson-Day; Mark A. Cochrane; Michael S. Hand
2016-01-01
We present a case study of the Las Conchas Fire (2011) to explore the role of previously burned areas (wildfires and prescribed fires) on suppression effectiveness and avoided exposure. Methodological innovations include characterisation of the joint dynamics of fire growth and suppression activities, development of a fire line effectiveness framework, and...
Seen areas and the distribution of fires about a lookout
Romain M. Mees
1978-01-01
From the location of a fire lookout and the sites of past fires within a given radius about a lookout, an estimate of the fire distribution with respect to distance from the lookout can be obtained. The estimated distribution can include all fires located within a given number of feet below the last maximum line of sight from the lookout. Seen areas for the same...
Analytical modeling of fire growth on fire-resistive wood-based materials with changing conditions
Mark A. Dietenberger
2006-01-01
Our analytical model of fire growth for the ASTM E 84 tunnel, which simultaneously predicts heat release rate, flame-over area, and pyrolysis area as functions of time for constant conditions, was documented in the 2001 BCC Symposium for different treated wood materials. The model was extended to predict ignition and fire growth on exterior fire-resistive structures...