Sample records for fire training pit

  1. Corrective action plan for corrective action Unit 342: Area 23 Mercury Fire Training Pit, Nevada Test Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nacht, S.

    1999-08-01

    The Mercury Fire Training Pit is a former fire training area located in Area 23 of the Nevada Test Site (NTS). The Mercury Fire Training Pit was used from approximately 1965 to the early 1990s to train fire-fighting personnel at the NTS, and encompasses an area approximately 107 meters (m) (350 feet [ft]) by 137 m (450 ft). The Mercury Fire Training Pit formerly included a bermed burn pit with four small burn tanks, four large above ground storage tanks an overturned bus, a telephone pole storage area, and areas for burning sheds, pallets, and cables. Closure activities will includemore » excavation of the impacted soil in the aboveground storage tank and burn pit areas to a depth of 1.5 m (5 ft), and excavation of the impacted surface soil downgradient of the former ASTs and burnpit areas to a depth of 0.3 m (1 ft). Excavated soil will be disposed in the Area 6 Hydrocarbon Landfill at the NTS.« less

  2. STS-32 crewmembers use water hose during exercises at JSC fire training pit

    NASA Technical Reports Server (NTRS)

    1989-01-01

    STS-32 Commander Daniel C. Brandenstein (left) and Pilot James D. Wetherbee handle water hose during fire training exercises conducted at JSC Fire Training Pit across from the Gilruth Center Bldg 207.

  3. STS-48 crew participates in JSC fire fighting and fire training exercises

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-48 Mission Specialist (MS) Charles D. Gemar opens water hose nozzle as he approaches a fire blazing in JSC's Fire Training Pit during fire fighting and fire training exercises. Pilot Kenneth S. Reightler, Jr steadies the hose behind Gemar. At Gemars right is an unidentified fire department Official, MS Mark N. Brown, and Commander John O. Creighton. Brown and Crieghton are obscured by the water spray. The Fire Training Pit is located across from the Gilruth Center Bldg 207.

  4. STS-47 crew participates in fire fighting exercises at JSC Fire Training Pit

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-47 Endeavour, Orbiter Vehicle (OV) 105, Mission Specialist (MS) N. Jan Davis (foreground) and MS and Payload Commander (PLC) Mark C. Lee, squinting and holding water hose, listen to instructions prior to participating in fire fighting exercises held at JSC's Fire Training Pit across from Gilruth Center Bldg 207.

  5. STS-42 crewmembers participate in JSC fire fighting training exercises

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-42 Discovery, Orbiter Vehicle (OV) 103, Payload Specialist Ulf D. Merbold (far left), fire fighting trainer (center), Payload Specialist Roberta L. Bondar (holding hose nozzle), and backup Payload Specialist Roger K. Crouch position water hoses in the direction of a blazing fire in JSC's Fire Training Pit. The crewmembers and backup are learning fire extinguishing techniques during fire fighting and fire training exercises held at JSC's Fire Training Pit located across from the Gilruth Center Bldg 207. Merbold is representing the European Space Agency (ESA) and Bondar is representing Canada during the International Microgravity Laboratory 1 (IML-1) mission aboard OV-103.

  6. STS-47 crew during JSC fire fighting exercises in the Fire Training Pit

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-47 Endeavour, Orbiter Vehicle (OV) 105, crewmembers line up along water hoses during JSC fire fighting exercises held at JSC's Fire Training Pit. In the foreground are (left to right) Pilot Curtis L. Brown, Jr, holding the hose nozzle, Mission Specialist (MS) N. Jan Davis, MS and Payload Commander (PLC) Mark C. Lee, and backup Payload Specialist Stan Koszelak, partially visible at the end of the line. In the background, manning a second hose are backup Payload Specialist Takao Doi, MS Jerome Apt, and Commander Robert L. Gibson. A veteran fire fighter (behind Brown) stands between the two hoses giving instructions. The Fire Training Pit is located across from the Gilruth Center Bldg 207. Doi represents Japan's National Space Development Agency (NASDA).

  7. STS-42 crewmembers participate in JSC fire fighting training exercises

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-42 Discovery, Orbiter Vehicle (OV) 103, Mission Specialist (MS) Norman E. Thagard, holding hose nozzle, is followed by Payload Specialist Ulf D. Merbold and backup Payload Specialist Kenneth Money as the team positions the water hose in the direction of a blazing fire at JSC's Fire Training Pit. A second team of crewmembers, manning another hose, forms a line parallel to the first. The crewmembers and backups are learning fire extinguishing techniques during fire fighting and fire training exercises held at JSC's Fire Training Pit located across from the Gilruth Center Bldg 207. Merbold is representing the European Space Agency (ESA) during the International Microgravity Laboratory 1 (IML-1) mission aboard OV-103.

  8. STS-47 crew during fire fighting exercises at JSC's Fire Training Pit

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-47 Endeavour, Orbiter Vehicle (OV) 105, crewmembers line up along water hoses to extinguish a blaze in JSC's Fire Training Pit during fire fighting exercises. Manning the hose in the foreground are Payload Specialist Mamoru Mohri, holding the hose nozzle, backup Payload Specialist Takao Doi, Mission Specialist (MS) Jerome Apt, and Commander Robert L. Gibson, at rear. Lined up on the second hose are Pilot Curtis L. Brown, Jr, holding the hose nozzle, followed by MS N. Jan Davis, MS and Payload Commander (PLC) Mark C. Lee, and backup Payload Specialist Stan Koszelak. A veteran firefighter monitors the effort from a position between the two hoses. In the background, backup Payload Specialist Chiaki Naito-Mukai, donning gloves, and MS Mae C. Jemison look on. The Fire Training Pit is located across from the Gilruth Center Bldg 207. Mohri, Doi, and Mukai all represent Japan's National Space Development Agency (NASDA).

  9. Optimization of Skill Retention in the U. S. Army through Initial Training Analysis and Design: Skill Sustainment Exercises. Volume 3.

    DTIC Science & Technology

    1983-05-01

    Firing data cards. PROCEDURES I. Prior to live fire exercises all firers must be oriented on range procedures. 2. Preparatory marksmanship training...Ordnance detail. 2. Range safety officer. 7. Medical personnel. 3. Firing line safety NCOs. 8. Control tower operators. i 4. Scorer (I per firer ). 9. Pit...phones and wire (for PIT commo). PROCEDURES I. Prior to live fire exercises, all firers must be oriented on range procedures. 2. Scorers are responsible

  10. STS-30 crewmembers participate in fire fighting training at JSC

    NASA Technical Reports Server (NTRS)

    1989-01-01

    STS-30 Atlantis, Orbiter Vehicle (OV) 104, crewmembers participate in fire fighting training at JSC's fire training pit across from the Gilruth Center Bldg 207. Commander David M. Walker and Pilot Ronald J. Grabe use fire extinguishers to control blaze. Fire / security staff member Robert Fife coaches the two crewmembers during the training exercise.

  11. Closure Report for Corrective Action Unit 342: Area 23 Mercury Fire Training Pit Nevada Test Site, Nevada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    C. M. Obi

    2000-04-01

    The purpose of this Closure Report (CR) is to provide documentation of the completed corrective action and to provide data confirming the corrective action. The corrective action was performed following the approved Corrective Action Plan (CAP) (U.S. Department of Energy [DOE], 1999b) and consisted of closure-in-place with partial excavation, disposal, backfilling, administrative controls, and post-closure monitoring. Soil with petroleum hydrocarbon concentrations above the Nevada Division of Environmental Protection (NDEP) Action Level of 100 milligrams per kilogram (mg/kg) (Nevada Administrative Code, 1996) was removed to a depth of 1.5 meters (m) (5 feet [ft]). The excavations were backfilled with clean fillmore » to restore the site and to prevent contact with deeper, closed-in-place soil that exceeded the NDEP Action Level. According to the Corrective Action Investigation Plan (CAIP) (DOE, 1998), the Mercury Fire Training Pit was used from approximately 1965 to the early 1990s to train fire-fighting and emergency response personnel at the NTS and encompasses an area approximately 85 by 115 m (280 by 380 ft). The location of the Mercury Fire Training Pit is shown in Figure 1 and a site plan is shown in Figure 2. The Mercury Fire Training Pit formerly included a bermed bum pit with four small bum tanks; four large above ground storage tanks (ASTS); an overturned bus, a telephone pole storage area; and several areas for burning sheds, pallets, and cables. During the active life of the Mercury Fire Training Pit, training events were conducted at least monthly and sometimes as often as weekly. Fuels burned during these events included off-specification or rust-contaminated gasoline, diesel, and aviation fuel (JP-4). Other items burned during these events included paint, tires, a pond liner, wood, paper, cloth, and copper cable. Approximately 570 liters (L) (150 gallons [gal]) of fuel were used for each training event resulting in an approximate total of 136,000 L (36,000 gal) of fuel used over the life of the Mercury Fire Training Pit. Unburned fuel was allowed to pool on the ground and was left to eventually volatilize or soak into the soil. In addition, fuels from the ASTS and fuels and fluids from the overturned bus leaked or spilled onto the ground. Approximately 19 L to 38 L (5 to 10 gal) of paint were also burned monthly until sometime in the 1970s.« less

  12. Decision Document for the Storm Water Outfalls/Industrial Wastewater Treatment Plant, Pesticide Rinse Area, Old Fire Fighting Training Pit, Illicit PCB Dump Site, and the Battery Acid Pit Fort Lewis, Washington

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cantrell, Kirk J; Liikala, Terry L; Strenge, Dennis L

    PNNL conducted independent site evaluations for four sites at Fort Lewis, Washington, to determine their suitability for closure on behalf of the installation. These sites were recommended for ''No Further Action'' by previous investigators and included the Storm Water Outfalls/Industrial Waste Water Treatment Plant (IWTP), the Pesticide Rinse Area, the Old Fire Fighting Training Pit, and the Illicit PCB Dump Site.

  13. Decision Document for the Storm Water Outfalls/Industrial Wastewater Treatment Plant, Pesticide Rinse Area, Old Fire Fighting Training Pit, Illicit PCB Dump Site, and the Battery Acid Pit Fort Lewis, Washington

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cantrell, Kirk J.; Liikala, Terry L.; Strenge, Dennis L.

    PNNL conducted independent site evaluations for four sites at Fort Lewis, Washington, to determine their suitability for closure on behalf of the installation. These sites were recommended for "No Further Action" by previous invesitgators and included the Storm Water Outfalls/Industrial Waste Water Treatment Plant (IWTP), the Pesticide Rinse Area, the Old Fire Fighting Training Pit, and the Illicit PCB Dump Site.

  14. STS-48 crew participates in JSC fire fighting and fire training exercises

    NASA Technical Reports Server (NTRS)

    1991-01-01

    In this overall view, STS-48 crewmembers approach a firey blaze armed with water hoses. Left to right are Mission Specialist (MS) Charles D. Gemar, Pilot Kenneth S. Reightler, Jr, an unidentified fire department Official, MS Mark N. Brown, and Commander John O. Creighton. These fire fighting and fire training exercises were conducted at JSC's Fire Training Pit located across from the Gilruth Center Bldg 207.

  15. Final Environmental Assessment For the Construction and Operation of a Fire Training Facility

    DTIC Science & Technology

    2010-04-29

    practice drafting (i.e., water uptake through hoses ) operations during live fires. The proposed drafting pit would also allow the department to...FTF to allow the Clear FD to practice drafting (i.e., water uptake through hoses ) operations during live fires. The proposed drafting pit would also...respirators, etc.), but trucks, hoses , and other large equipment would need to be supplied by the host fire department (so as not to leave Clear AFS

  16. STS-30 crewmembers participate in fire fighting training at JSC

    NASA Technical Reports Server (NTRS)

    1989-01-01

    STS-30 Atlantis, Orbiter Vehicle (OV) 104, crewmembers participate in fire fighting training at JSC's fire training pit across from the Gilruth Center Bldg 207. Crewmembers listen to hose and nozzle instructions given by fire / security staff member Robert Fife. Left to right Commander David M. Walker (holding hose nozzle), Mission Specialist (MS) Mark C. Lee, MS Mary L. Cleave, Pilot Ronald J. Grabe, and MS Norman E. Thagard.

  17. STS-48 crew participates in JSC fire fighting and fire training exercises

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-48 Pilot Kenneth S. Reightler, Jr directs water hose nozzle as Mission Specialist (MS) Charles D. Gemar pulls the hose toward the blaze. In the background, an unidentified fire department Official instructs Commander John O. Creighton and MS Mark N. Brown (wearing cap), manning a second hose, on how to approach the blaze. These fire fighting and fire training exercises were conducted at JSC's Fire Training Pit located across from the Gilruth Center Bldg 207.

  18. Fire/security staff member instructs STS-29 crew on fire extinguisher usage

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-29 Discovery, Orbiter Vehicle (OV) 103, crewmembers are trained in procedures to follow in the event of a fire. Here, the crew is briefed on the correct handling of the fire extinguisher by Robert Fife (far left) of NASA's fire / security staff. Pictured, left to right are Pilot John E. Blaha, Commander Michael L. Coats, Mission Specialist (MS) Robert C. Springer, MS James F. Buchli, and MS James P. Bagian. The in fire fighting training took place at JSC's fire training pit across from the Gilruth Center Bldg 207.

  19. STS-29 crewmembers participate in fire fighting training at JSC

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-29 Discovery, Orbiter Vehicle (OV) 103, crewmembers participate in fire fighting training at JSC's fire training pit across from the Gilruth Center Bldg 207. Mission Specialist (MS) Robert C. Springer (left) and Pilot John E. Blaha, controlling water hose nozzles, approach the blaze and attempt to extinguish it. They are followed by fire / security staff member Robert Fife (between hoses), Commander Michael L. Coats (left), and MS James P. Bagian.

  20. 14 CFR 139.321 - Handling and storing of hazardous substances and materials.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...

  1. 14 CFR 139.321 - Handling and storing of hazardous substances and materials.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...

  2. 14 CFR 139.321 - Handling and storing of hazardous substances and materials.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...

  3. 14 CFR 139.321 - Handling and storing of hazardous substances and materials.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...

  4. 14 CFR 139.321 - Handling and storing of hazardous substances and materials.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...) Public protection. (3) Control of access to storage areas. (4) Fire safety in fuel farm and storage areas. (5) Fire safety in mobile fuelers, fueling pits, and fueling cabinets. (6) Training of fueling personnel in fire safety in accordance with paragraph (e) of this section. Such training at Class III...

  5. STS-40 MS Seddon pauses during fire fighting training at JSC's Fire Pit

    NASA Image and Video Library

    1990-08-22

    S90-46497 (18 Aug 1990) --- Astronaut Rhea Seddon, STS-40 mission specialist, takes a break from firefighting training at the Johnson Space Center (JSC). In less than a year Dr. Seddon will be joined by four NASA astronauts and two payload specialists for the Spacelab Life Sciences (SLS-1) mission aboard Columbia.

  6. STS-32 crewmembers use water hoses during fire fighting training at JSC

    NASA Image and Video Library

    1989-09-22

    STS-32 crewmembers use water hoses during fire fighting exercises at JSC's Fire Training Pit across from the Gilruth Center Bldg 207. Mission Specialist (MS) G. David Low with nozzle open directs water into the fire as fire/ security personnel coaches and instructs him on his attempt to extinguish the blaze. MS Bonnie J. Dunbar maneuvers the hose behind Low. A second group of crewmembers alongside Low and Dunbar, MS Marsha S. Ivins, holding hose nozzle, Commander Daniel C. Brandenstein, and Pilot James D. Wetherbee position themselves before opening hose nozzle.

  7. STS-32 crewmembers use water hoses during fire fighting training at JSC

    NASA Technical Reports Server (NTRS)

    1989-01-01

    STS-32 crewmembers use water hoses during fire fighting exercises at JSC's Fire Training Pit across from the Gilruth Center Bldg 207. Mission Specialist (MS) G. David Low with nozzle open directs water into the fire as fire/ security personnel coaches and instructs him on his attempt to extinguish the blaze. MS Bonnie J. Dunbar maneuvers the hose behind Low. A second group of crewmembers alongside Low and Dunbar, MS Marsha S. Ivins, holding hose nozzle, Commander Daniel C. Brandenstein, and Pilot James D. Wetherbee position themselves before opening hose nozzle.

  8. Accounting for Mass Transfer Kinetics when Modeling the Impact of Low Permeability Layers in a Groundwater Source Zone on Dissolved Contaminant Fate and Transport

    DTIC Science & Technology

    2014-03-27

    Clay Interface) ...................................................................................................... 40 Figure 9: Time-Dependent...vs Constant Dissolution Rate BTCs (Monitoring Well in Clay ...pits, poured down sanitary sewer systems, and partially burned in fire training pits. Poor handling and disposal of chlorinated solvents have

  9. Appropriate Technology for Treating Wastewater at Remote Sites on Army Installations: Preliminary Findings

    DTIC Science & Technology

    1984-04-01

    firing ranges, and training areas--four conventional methods have been used to treat human wastes: trenching and cat holing, pit latrines, vault toilets...stations, and training and recrea- tional areas. The Army now uses four conventional methods to treat human wastes at such sites: trenching and cat ...holing, pit latrines, vault toilets, and chemical toilets ("port-a-pots"). Trenching and cat holing are used when troops are on bivouac; waste is

  10. ENHANCED REMEDIATION DEMONSTRATIONS AT HILL AFB: INTRODUCTION

    EPA Science Inventory

    Nine enhanced aquifer remediation technologies were demonstrated side-by-side at a Hill Air Force Base Chemical Disposal Pit/Fire Training Area site. The demonstrations were performed inside 3 x 5 m cells isolated from the surrounding shallow aquifer by steel piling. The site w...

  11. Geologic, geotechnical, and geophysical properties of core from the Acme Fire-Pit-1 drill hole, Sheridan County, Wyoming

    USGS Publications Warehouse

    Collins, Donley S.

    1983-01-01

    A preliminary core study from the Acme Fire-Pit-1 drill hole, Sheridan County, Wyoming, revealed that the upper portion of the core had been baked by a fire confined to the underlying Monarch coal bed. The baked (clinkered) sediment above the Monarch coal bed was determined to have higher point-load strength values (greater than 2 MPa) than the sediment under the burned coal

  12. Heart rate and core temperature responses of elite pit crews during automobile races.

    PubMed

    Ferguson, David P; Bowen, Robert S; Lightfoot, J Timothy

    2011-08-01

    There is limited information regarding the physiological and psychological demands of the racing environment, and the subsequent effect on the performance of pit crew athletes. The purpose of this study was to evaluate heart rates (HRs) and core body temperatures (CTs) of pit crew athletes in the race environment. The HR and CT of pit crew athletes (n = 7) and control subjects were measured during 6 National Association for Stock Car Automobile Racing Sprint Cup races using ingestible sensors (HQ Inc, Palmetto, FL, USA). The HR and CT were measured before each race, at 15-minute intervals during the race, and upon completion of each pit stop. Compared to the control subject at each race, the pit crew athletes had significantly (p = 0.014) lower core temperatures (CTs). The pit crew athletes displayed higher HRs on the asphalt tracks than on concrete tracks (p = 0.011), and HR responses of the crew members were significantly (p = 0.012) different between pit crew positions, with the tire changers and jackman exhibiting higher HRs than the tire carriers. Unexpectedly, the CTs of the pit crew athletes were not elevated in the race environment, despite high ambient temperatures and the extensive fire-protection equipment (e.g., helmet, suit, gloves) each pit crew athlete wore. The lack of CT change is possibly the result of the increased HR more efficiently shunting blood to the skin and dissipating heat as a consequence of the athletes' extensive training regimen and ensuing heat acclimation. Additionally, it is possible that psychological stress unique to several of the tracks provided an additive effect resulting in increased heart rates.

  13. Estimating root biomass and distribution after fire in a Great Basin woodland using cores and pits

    Treesearch

    Benjamin M. Rau; Dale W. Johnson; Jeanne C. Chambers; Robert R. Blank; Annmarie Lucchesi

    2009-01-01

    Quantifying root biomass is critical to an estimation and understanding of ecosystem net primary production, biomass partitioning, and belowground competition. We compared 2 methods for determining root biomass: a new soil-coring technique and traditional excavation of quantitative pits. We conducted the study in an existing Joint Fire Sciences demonstration area in...

  14. Novel approach for extinguishing large-scale coal fires using gas-liquid foams in open pit mines.

    PubMed

    Lu, Xinxiao; Wang, Deming; Qin, Botao; Tian, Fuchao; Shi, Guangyi; Dong, Shuaijun

    2015-12-01

    Coal fires are a serious threat to the workers' security and safe production in open pit mines. The coal fire source is hidden and innumerable, and the large-area cavity is prevalent in the coal seam after the coal burned, causing the conventional extinguishment technology difficult to work. Foams are considered as an efficient means of fire extinguishment in these large-scale workplaces. A noble foam preparation method is introduced, and an original design of cavitation jet device is proposed to add foaming agent stably. The jet cavitation occurs when the water flow rate and pressure ratio reach specified values. Through self-building foaming system, the high performance foams are produced and then infused into the blast drilling holes at a large flow. Without complicated operation, this system is found to be very suitable for extinguishing large-scale coal fires. Field application shows that foam generation adopting the proposed key technology makes a good fire extinguishment effect. The temperature reduction using foams is 6-7 times higher than water, and CO concentration is reduced from 9.43 to 0.092‰ in the drilling hole. The coal fires are controlled successfully in open pit mines, ensuring the normal production as well as the security of personnel and equipment.

  15. Utilization of open pit burned household waste ash--a feasibility study in Dhaka.

    PubMed

    Haque, Md Obaidul; Sharif, Ahmed

    2014-05-01

    Informal incineration or open pit burning of waste materials is a common practice in the peripheral area of Dhaka, one of the fastest growing mega-cities in the world. This study deals with the effect of open pit burned (i.e. open burned) household waste bottom ash on fired clay bricks. Between 0 to 50% (by weight) of open pit burned household waste bottom ash was mixed with clay to make bricks. The molded specimens were air-dried at room temperature for 24 h and then oven dried at 100 °C for another 24 h to remove the water. The raw bricks were fired in a muffle furnace to a designated temperature (800, 900 and 1000 °C, respectively). The firing behaviour (mechanical strength, water absorption and shrinkage) was determined. The microstructures, phase compositions and leachates were evaluated for bricks manufactured at different firing temperatures. These results demonstrate that open pit burned ash can be recycled in clay bricks. This study also presents physical observations of the incinerated ash particles and determination of the chemical compositions of the raw materials by wet analysis. Open pit burned ash can be introduced easily into bricks up to 20% wt. The concentrations of hazardous components in the leachates were below the standard threshold for inert waste category landfill and their environmental risk during their use-life step can be considered negligible.

  16. Addendum to the Closure Report for Corrective Action Unit 342: Area 23 Mercury Fire Training Pit Nevada Test Site, Nevada, Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lynn Kidman

    This document constitutes an addendum to the April 2000, Closure Report for Corrective Action Unit 342: Area 23 Mercury Fire Training Pit as described in the document Recommendations and Justifications for Modifications for Use Restrictions Established under the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office Federal Facility Agreement and Consent Order (UR Modification document) dated February 2008. The UR Modification document was approved by NDEP on February 26, 2008. The approval of the UR Modification document constituted approval of each of the recommended UR modifications. In conformance with the UR Modification document, this addendum consists of:more » • This cover page that refers the reader to the UR Modification document for additional information • The cover and signature pages of the UR Modification document • The NDEP approval letter • The corresponding section of the UR Modification document This addendum provides the documentation justifying the cancellation of the UR for CAS 23-56-01, Former Mercury Fire Training Pit. This UR was established as part of a Federal Facility Agreement and Consent Order (FFACO) corrective action and is based on the presence of contaminants at concentrations greater than the action levels established at the time of the initial investigation (FFACO, 1996; as amended August 2006). Since this UR was established, practices and procedures relating to the implementation of risk-based corrective actions (RBCA) have changed. Therefore, this UR was re-evaluated against the current RBCA criteria as defined in the Industrial Sites Project Establishment of Final Action Levels (NNSA/NSO, 2006c). This re-evaluation consisted of comparing the original data (used to define the need for the UR) to risk-based final action levels (FALs) developed using the current Industrial Sites RBCA process. The re-evaluation resulted in a recommendation to remove the UR because contamination is not present at the site above the risk-based FALs. Requirements for inspecting and maintaining this UR will be canceled, and the postings and signage at this site will be removed. Fencing and posting may be present at this site that are unrelated to the FFACO UR such as for radiological control purposes as required by the NV/YMP Radiological Control Manual (NNSA/NSO, 2004f). This modification will not affect or modify any non-FFACO requirements for fencing, posting, or monitoring at this site.« less

  17. VOC identification and inter-comparison from laboratory biomass burning using PTR-MS and PIT-MS

    Treesearch

    C. Warneke; J. M. Roberts; P. Veres; J. Gilman; W. C. Kuster; I. Burling; R. Yokelson; J. A. de Gouw

    2011-01-01

    Volatile organic compounds (VOCs) emitted from fires of biomass commonly found in the southeast and southwest U.S. were investigated with PTR-MS and PIT-MS, which are capable of fast measurements of a large number of VOCs. Both instruments were calibrated with gas standards and mass dependent calibration curves are determined. The sensitivity of the PIT-MS linearly...

  18. Analytical results from an environmental investigation of six sites on Kirtland Air Force Base, New Mexico, 1993-94

    USGS Publications Warehouse

    Wilcox, Ralph

    1995-01-01

    The six sites investigated include silver recovery units; a buried caustic drain line; a neutralization pit; an evaporation/infiltration pond; the Manzano fire training area; and a waste oil underground storage tank. Environmental samples of soil, pond sediment, soil gas, and water and gas in floor drains were collected and analyzed. Field quality-control samples were also collected and analyzed in association with the environmental samples. The six sites were investigated because past or current activities could have resulted in contamination of soil, pond sediment, or water and sediment in drains.

  19. Microbial contents of soil from fire pits

    NASA Astrophysics Data System (ADS)

    Moon, K.; Esparza, V.; de Sandre, J.; Cheney, S.; Anderson, A.; White, M. A.

    2006-12-01

    Forest fires generate polycylic aromatic hydrocarbons (PAHs) that can lead to carcinogenic compounds, which are potential health risks. PAHs can be degraded to water and carbon dioxide by certain soil microbes. Thus, during participation in a NASA-funded summer research experience at Utah State University, our high school student team sampled soils from a month-old fire pit in which plant materials had been burnt. We detected in soil samples, from surface, 10 and 20 cm depths, microbes that would grow on a defined minimal medium source. Other microbes were cultured from the roots of plants that had established at the fire pit. A diversity of microbes was present in all samples based on visible differences in cell shape and color. It was surprising that the surface ash, although exposed to sunlight over the month interval, had culturable colonies. Many of these culturable bacteria were pigmented perhaps as a protection against UV radiation from the sun. We searched for genes in the microbes that encoded enzymes called dioxygenases that in other bacteria are involved in degradation of PAHs. This test involved using polymerase chain reactions to detect the genes. PCR products were found in two of the fifteen isolates tested although their sizes differed from the control gene product from a PAH-degrading mycobacterium isolate. These results suggest that the soils did contain microbes with the possible potential to alter the PAH compounds generated from vegetation fires. Our findings serve as a starting point for future studies looking at recovery and remediation of fired acreages.

  20. Particle and gas emissions from a simulated coal-burning household fire pit.

    PubMed

    Tian, Linwei; Lucas, Donald; Fischer, Susan L; Lee, S C; Hammond, S Katharine; Koshland, Catherine P

    2008-04-01

    An open fire was assembled with firebricks to simulate the household fire pit used in rural China, and 15 different coals from this area were burned to measure the gaseous and particulate emissions. Particle size distribution was studied with a microorifice uniform-deposit impactor (MOUDI). Over 90% of the particulate mass was attributed to sub-micrometer particles. The carbon balance method was used to calculate the emission factors. Emission factors for four pollutants (particulate matter, CO2, total hydrocarbons, and NOx) were 2-4 times higherfor bituminous coals than for anthracites. In past inventories of carbonaceous emissions used for climate modeling, these two types of coal were not treated separately. The dramatic emission factor difference between the two types of coal warrants attention in the future development of emission inventories.

  1. 76 FR 19765 - Toutant Hydropower Inc.; Notice of Application Accepted for Filing, Soliciting Comments, Motions...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-08

    ... refurbished and re-installed small ``fire pump'' turbine direct coupled to a 120 kilowatt, 2300 volt, AC synchronous vertically mounted generator. The ``fire pump'' turbine is located in the southwest corner of the existing turbine pit. The ``fire pump'' turbine has a rated maximum hydraulic capacity of 106 cubic feet...

  2. Haulage Truck Operator. Open Pit Mining Job Training Series.

    ERIC Educational Resources Information Center

    British Columbia Dept. of Education, Victoria.

    This training outline for haulage truck operators, one in a series of eight outlines, is designed primarily for company training foremen or supervisors and for trainers to use as an industry-wide guideline for heavy equipment operator training in open pit mining in British Columbia. Intended as a guide for preparation of lesson plans both for…

  3. Rotary Drill Operator. Open Pit Mining Job Training Series.

    ERIC Educational Resources Information Center

    Savilow, Bill

    This training outline for rotary drill operators, one in a series of eight outlines, is designed primarily for company training foremen or supervisors and for trainers to use as an industry-wide guideline for heavy equipment operator training in open pit mining in British Columbia. Intended as a guide for preparation of lesson plans both for…

  4. Track Dozer Operator. Open Pit Mining Job Training Series.

    ERIC Educational Resources Information Center

    British Columbia Dept. of Education, Victoria.

    This training outline for track dozer operators, one in a series of eight outlines, is designed primarily for company training foremen or supervisors and for trainers to use as an industry-wide guideline for heavy equipment operator training in open pit mining in British Columbia. Intended as a guide for preparation of lesson plans both for…

  5. Grader Operator. Open Pit Mining Job Training Series.

    ERIC Educational Resources Information Center

    Savilow, Bill

    This training outline for grader operators, one in a series of eight outlines, is designed primarily for company training foremen or supervisors and for trainers to use as an industry-wide guideline for heavy equipment operator training in open pit mining in British Columbia. Intended as a guide for preparation of lesson plans both for classroom…

  6. Heavy Duty Tireman. Open Pit Mining Job Training Series.

    ERIC Educational Resources Information Center

    McColman, Don

    This training outline for heavy duty tiremen, one in a series of eight outlines, is designed primarily for company training foremen or supervisors and for trainers to use as an industry-wide guideline for heavy equipment operator training in open pit mining in British Columbia. Intended as a guide for preparation of lesson plans both for classroom…

  7. Rubber Tire Dozer Operator. Open Pit Mining Job Training Series.

    ERIC Educational Resources Information Center

    British Columbia Dept. of Education, Victoria.

    This training outline for rubber tire dozer operators, one in a series of eight outlines, is designed primarily for company training foremen or supervisors and for trainers to use as an industry-wide guideline for heavy equipment operator training in open pit mining in British Columbia. Intended as a guide for preparation of lesson plans both for…

  8. Front End Loader Operator. Open Pit Mining Job Training Series.

    ERIC Educational Resources Information Center

    Savilow, Bill

    This training outline for front end loader operators, one in a series of eight outlines, is designed primarily for company training foremen or supervisors and for trainers to use as an industry-wide guideline for heavy equipment operator training in open pit mining in British Columbia. Intended as a guide for preparation of lesson plans both for…

  9. Shovel Operator. Open Pit Mining Job Training Series.

    ERIC Educational Resources Information Center

    Hartley, Larry

    This training outline for shovel operators, one in a series of eight outlines, is designed primarily for company training foremen or supervisors and for trainers to use as an industry-wide guideline for heavy equipment operator training in open pit mining in British Columbia. Intended as a guide for preparation of lesson plans both for classroom…

  10. 89. ARAIII. Petrochem oilfired gas heater installed in reactor building ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    89. ARA-III. Petro-chem oil-fired gas heater installed in reactor building (ARA-608). View is at floor level. Shows hand rails around heater pit and top of pit extending upwards through ceiling. January 20, 1959. Ineel photo no. 59-321. Photographer: Jack L. Anderson. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  11. Pitting failure of copper pipings for emergency fire sprinkler in ground water

    NASA Astrophysics Data System (ADS)

    Baek, Seung-won; Lee, Jong-kwon; Kim, Jong-jip; Kim, Kyung-ja

    2015-05-01

    The possibility of microbiologically influenced corrosion was investigated in the early pitted copper pipes. The pipes were installed for less than 6 months as an immergency fire sprinkler. The bacteria were cultured by sampling of corrosion by-product near pits on failed copper pipes for the aerobic as well as anaerobic bacteria. However, only aerobic bacteria was found, which were Micrococcus Luteus and Bacillus sp.. The corrosion rate of copper pipes were studied by weight loss in the groundwater and polarization method. In immersion test as well as the electrochemical polarization test in ground water, only Micrococcus Luteus could activate corrosion of copper by 20% and 15%, respectively. On the other hand, Bacillus sp. showed little effect on corrosion in the above two tests. The shape and characteristics of failed copper pipes as well as simulated copper were investigated using stereoscope, optical microscopy, scanning electron microscope and EDS. The cause of pits were discussed, related with the dissolved copper concentrations, pH, and optical density. It could be concluded that the early failure of copper pipings could be ascribed to the acceration of copper in the presence of bacteria, i.e., Micrococcus Luteus.

  12. Fire tests to evaluate the potential fire threat and its effects on HEPA filter integrity in cell ventilation at the Oak Ridge National Laboratory, Building 7920

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hasegawa, H.K.; Staggs, K.J.; Doughty, S.M.

    1992-12-01

    As a result of a DOE (Tiger Team) Technical Safety Appraisal (November 1990) of the Radiochemical Engineering Development Center (REDC), ORNL Building 7920, a number of fire protection concerns were identified. The primary concern was the perceived loss of ventilation system containment due to the thermal destruction and/or breaching of the prefilters and/or high-efficiency particulate air filters (HEPA `s) and the resultant radioactive release to the external environment. The following report describes the results of an extensive fire test program performed by the Fire Research Discipline (FRD) of the Special Projects Division of Lawrence Livermore National Lab (LLNL) and fundedmore » by ORNL to address these concerns. Full scale mock-ups of a REDC hot cell tank pit, adjacent cubicle pit, and associated ventilation system were constructed at LLNL and 13 fire experiments were conducted to specifically answer the questions raised by the Tiger Team. Our primary test plan was to characterize the burning of a catastrophic solvent spill (kerosene) of 40 liters and its effect on the containment ventilation system prefilters and HEPA filters. In conjunction with ORNL and Lockwood Greene we developed a test matrix that assessed the fire performance of the prefilters and HEPA filters; evaluated the fire response of the fiber reinforced plastic (FRP) epoxy ventilation duct work; the response and effectiveness of the fire protection system, the effect of fire in a cubicle on the vessel off-gas (VOG) elbow, and other fire safety questions.« less

  13. How food cues can enhance and inhibit motivation to obtain and consume food.

    PubMed

    Colagiuri, Ben; Lovibond, Peter F

    2015-01-01

    Learning may play an important role in over-eating. One example is Pavlovian-to-instrumental transfer (PIT), whereby reward cues facilitate responding to obtain that reward. Whilst there is increasing research indicating PIT for food in humans, these studies have exclusively tested PIT under instrumental extinction (i.e. when the food is no longer available), which may reduce their ecological validity. To address this, we conducted two experiments exploring PIT for food in humans when tested under instrumental reinforcement. Participants first underwent Pavlovian discrimination training with an auditory cue paired with a chocolate reward (CS+) and another auditory cue unpaired (CS-). In instrumental training participants learnt to press a button to receive the chocolate reward on a VR10 schedule. In the test phase, each CS was presented whilst participants maintained the opportunity to press the button to receive chocolate. In Experiment 1, the PIT test was implemented after up to 20 min of instrumental training (satiation) whereas in Experiment 2 it was implemented after only 4 min of instrumental training. In both experiments there was evidence for differential PIT, but the pattern differed according to the rate of responding at the time of the PIT test. In low baseline responders the CS+ facilitated both button press responding and consumption, whereas in high baseline responders the CS- suppressed responding. These findings suggest that both excitatory and inhibitory associations may be learnt during PIT training and that the expression of these associations depends on motivation levels at the time the cues are encountered. Particularly concerning is that a food-paired cue can elicit increased motivation to obtain and consume food even when the participant is highly satiated and no longer actively seeking food, as this may be one mechanism by which over-consumption is maintained. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Collective secondary cremation in a pit grave: a unique funerary context in Portuguese Chalcolithic burial practices.

    PubMed

    Silva, A M; Leandro, I; Pereira, D; Costa, C; Valera, A C

    2015-02-01

    Perdigões is a large site with a set of ditched enclosures located at Reguengos de Monsaraz, Alentejo, South Portugal. Recently at the central area of this site burnt human remains were found in a pit (#16). This structure had inside human remains, animal bones (namely pig, sheep or goat, cattle, dog, deer and rabbit), shards, ivory idols and arrowheads. All have been subjected to fire and later deposited in that pit, resulting in a secondary disposal of human bones. The recovered fragmented human bones (4845.18 g) correspond to a minimal number of 9 individuals: 6 adults and 3 sub-adults. The aim of this work is to document and interpret this funerary context based on the study of the recovered human remains. For that purpose, observations of all alterations due to fire, such as colour change and type of bone distortion, as well as anthropological data were collected. The data obtained suggest that these human remains were probably intentionally cremated, carefully collected and finally deposited in this pit. The cremation was conducted on probably complete corpses, some of them still fairly fresh and fleshed, as some bones presented thumbnail fractures. The collective cremation of the pit 16 represents an unprecedented funerary context for Portuguese, and Iberian Peninsula, Chalcolithic burial practices. Moreover, it is an example of the increasing diversity of mortuary practices of Chalcolithic human populations described in present Portuguese territory, as well as, in the Iberian Peninsula. Copyright © 2014 Elsevier GmbH. All rights reserved.

  15. Installation Restoration Program, Phase 1. Records Search, Wheeler Air Force Base, Oahu, Hawaii

    DTIC Science & Technology

    1983-07-01

    the 3vegetation was already exotic, consisting of trees such as guava , koa haole, eucalyptus and silver oak, and shrubs and 3 grasses including lantana...Alkalioo Soap 5 gal GrounOd S~r Of f Base Fire Pit fir.Pit Of f Base PmecI" CoCAClo 20$ P 680 1S Sa.L Cro-..d tAint 10-20 gal 8w L..dt±u Off km. Thinmar

  16. Quantifying black carbon deposition over the Greenland ice sheet from forest fires in Canada

    NASA Astrophysics Data System (ADS)

    Thomas, J. L.; Polashenski, C. M.; Soja, A. J.; Marelle, L.; Casey, K. A.; Choi, H. D.; Raut, J.-C.; Wiedinmyer, C.; Emmons, L. K.; Fast, J. D.; Pelon, J.; Law, K. S.; Flanner, M. G.; Dibb, J. E.

    2017-08-01

    Black carbon (BC) concentrations observed in 22 snowpits sampled in the northwest sector of the Greenland ice sheet in April 2014 have allowed us to identify a strong and widespread BC aerosol deposition event, which was dated to have accumulated in the pits from two snow storms between 27 July and 2 August 2013. This event comprises a significant portion (57% on average across all pits) of total BC deposition over 10 months (July 2013 to April 2014). Here we link this deposition event to forest fires burning in Canada during summer 2013 using modeling and remote sensing tools. Aerosols were detected by both the Cloud-Aerosol Lidar with Orthogonal Polarization (on board CALIPSO) and Moderate Resolution Imaging Spectroradiometer (Aqua) instruments during transport between Canada and Greenland. We use high-resolution regional chemical transport modeling (WRF-Chem) combined with high-resolution fire emissions (FINNv1.5) to study aerosol emissions, transport, and deposition during this event. The model captures the timing of the BC deposition event and shows that fires in Canada were the main source of deposited BC. However, the model underpredicts BC deposition compared to measurements at all sites by a factor of 2-100. Underprediction of modeled BC deposition originates from uncertainties in fire emissions and model treatment of wet removal of aerosols. Improvements in model descriptions of precipitation scavenging and emissions from wildfires are needed to correctly predict deposition, which is critical for determining the climate impacts of aerosols that originate from fires.

  17. Quantifying Black Carbon Deposition Over the Greenland Ice Sheet from Forest Fires in Canada

    NASA Technical Reports Server (NTRS)

    Thomas, J. L.; Polashenski, C. M.; Soja, Amber J.; Marelle, L.; Casey, K. A.; Choi, H. D.; Raut, J.-C.; Wiedinmyer, C.; Emmons, L. K.; Fast, J. D.; hide

    2017-01-01

    Black carbon (BC) concentrations observed in 22 snowpits sampled in the northwest sector of the Greenland ice sheet in April 2014 have allowed us to identify a strong and widespread BC aerosol deposition event, which was dated to have accumulated in the pits from two snow storms between 27 July and 2 August 2013. This event comprises a significant portion (57 on average across all pits) of total BC deposition over 10 months (July 2013 to April 2014). Here we link this deposition event to forest fires burning in Canada during summer 2013 using modeling and remote sensing tools. Aerosols were detected by both the Cloud-Aerosol Lidar with Orthogonal Polarization (on board CALIPSO) and Moderate Resolution Imaging Spectroradiometer (Aqua) instruments during transport between Canada and Greenland. We use high-resolution regional chemical transport modeling (WRF-Chem) combined with high-resolution fire emissions (FINNv1.5) to study aerosol emissions, transport, and deposition during this event. The model captures the timing of the BC deposition event and shows that fires in Canada were the main source of deposited BC. However, the model underpredicts BC deposition compared to measurements at all sites by a factor of 2100. Underprediction of modeled BC deposition originates from uncertainties in fire emissions and model treatment of wet removal of aerosols. Improvements in model descriptions of precipitation scavenging and emissions from wildfires are needed to correctly predict deposition, which is critical for determining the climate impacts of aerosols that originate from fires.

  18. Modeling Forest Understory Fires in an Eastern Amazonian Landscape

    NASA Technical Reports Server (NTRS)

    Alencar, A. A. C.; Solorzano, L. A.; Nepstad, D. C.

    2004-01-01

    Forest understory fires are an increasingly important cause of forest impoverishment in Ammonia, but little is known of the landscape characteristics and climatic phenomena that determine their occurrence. We developed empirical functions relating the occurrence of understory fires to landscape features near Paragominas, a 35- yr-old ranching and logging center in eastern Ammonia. An historical sequence of maps of forest understory fire was created based on field interviews With local farmers and Landsat TM images. Several landscape features that might explain spatial variations in the occurrence of understory fires were also mapped and co-registered for each of the sample dates, including: forest fragment size and shape, forest impoverishment through logging and understory fires, source of ignition (settlements and charcoal pits), roads, forest edges, and others. The spatial relationship between forest understory fire and each landscape characteristic was tested by regression analyses. Fire probability models were then developed for various combinations of landscape characteristics. The analyses were conducted separately for years of the El Nino Southern Oscillation (ENSO), which are associated with severe drought in eastern Amazonia, and non-ENS0 years. Most (91 %) of the forest area that burned during the 10-yr sequence caught fire during ENSO years, when severe drought may have increased both forest flammability and the escape of agricultural management fires. Forest understory fires were associated with forest edges, as reported in previous studies from Ammonia. But the strongest predictor of forest fire was the percentage of the forest fragment that had been previously logged or burned. Forest fragment size, distance to charcoal pits, distance to agricultural settlement, proximity to forest edge, and distance to roads were also correlated with forest understory fire. Logistic regression models using information on fragment degradation and distance to ignition sources accurately predicted the location of lss than 80% of the forest fires observed during the ENSO event of 1997- 1998. In this Amazon landscape, forest understory fire is a complex function of several variables that influence both the flammability and ignition exposure of the forest.

  19. The Coast Artillery Journal. Volume 65, Number 6, December 1926

    DTIC Science & Technology

    1926-12-01

    both mortars are fired from the same pit, due to the increased concussion and general pit activity. A more thorough test of the system will result...Chiiteau-Salins. This result will be attained by the occupation of the heights of Baronville-~forhange. Also to begin the encirclement of Metz on the right...assure its full success. The enemy, in fact, considers that Metz and the Lorraine front constitute the left pillar of his dispositions, and we must seek

  20. Open-pit coal mine production sequencing incorporating grade blending and stockpiling options: An application from an Indian mine

    NASA Astrophysics Data System (ADS)

    Kumar, Ashish; Chatterjee, Snehamoy

    2017-05-01

    Production scheduling is a crucial aspect of the mining industry. An optimal and efficient production schedule can increase the profits manifold and reduce the amount of waste to be handled. Production scheduling for coal mines is necessary to maintain consistency in the quality and quantity parameters of coal supplied to power plants. Irregularity in the quality parameters of the coal can lead to heavy losses in coal-fired power plants. Moreover, the stockpiling of coal poses environmental and fire problems owing to low incubation periods. This article proposes a production scheduling formulation for open-pit coal mines including stockpiling and blending opportunities, which play a major role in maintaining the quality and quantity of supplied coal. The proposed formulation was applied to a large open-pit coal mine in India. This contribution provides an efficient production scheduling formulation for coal mines after utilizing the stockpile coal within the incubation periods with the maximization of discounted cash flows. At the same time, consistency is maintained in the quality and quantity of coal to power plants through blending and stockpiling options to ensure smooth functioning.

  1. Optimizing the physical conditioning of the NASCAR sprint cup pit crew athlete.

    PubMed

    Ferguson, David P; Davis, Adam M; Lightfoot, J Timothy

    2015-03-01

    Stock car racing is the largest spectator sport in the United States. As a result, National Association for Stock Car Automobile Racing (NASCAR) Sprint Cup teams have begun to invest in strength and conditioning programs for their pit crew athletes. However, there is limited knowledge regarding the physical characteristics of elite NASCAR pit crew athletes, how the NASCAR Sprint Cup season affects basic physiological parameters such as body composition, and what is the most appropriate physical training program that meets the needs of a pit crew athlete. We conducted 3 experiments involving Sprint Cup motorsport athletes to determine predictors of success at the elite level, seasonal physiological changes, and appropriate physical training programs. Our results showed that hamstring flexibility (p = 0.015) and the score on the 2-tire front run test (p = 0.012) were significant predictors of NASCAR Sprint Cup Pit Crew athlete performance. Additionally, during the off season, pit crew athletes lost lean body mass, which did not return until the middle of the season. Therefore, a strength and conditioning program was developed to optimize pit crew athlete performance throughout the season. Implementation of this strength and conditioning program in 1 NASCAR Sprint Cup team demonstrated that pit crew athletes were able to prevent lean body mass loss and have increased muscle power output from the start of the season to the end of the season.

  2. Extinction of specific stimulus-outcome (S-O) associations in Pavlovian learning with an extended CS procedure.

    PubMed

    Delamater, Andrew R; Schneider, Kevin; Derman, Rifka C

    2017-07-01

    Three experiments with male and female rats were conducted to examine the effects of Pavlovian extinction training on Pavlovian-to-instrumental transfer (PIT) in a task in which the unconditioned stimulus (US) was presented at an early time point within an extended conditioned stimulus (CS). Two instrumental responses were trained with different reinforcing outcomes (R1-O1, R2-O2) and then, independently, 2 stimuli were trained with those outcomes (S1-O1, S2-O2). One group then underwent an extinction treatment (S1-, S2-) and a second was merely exposed to the experimental contexts without any stimulus events. Finally, the effects of the 2 stimuli on instrumental responding were assessed in PIT tests. Across experiments we varied the number of Pavlovian training trials prior to extinction (8, 16, or 64 trials) and the length of time following extinction prior to test (i.e., 1 or 21 days, in a test for spontaneous recovery). We observed that outcome-specific PIT was reduced by extinction in all of our training conditions and that this extinction effect was durable, surviving a 3-week spontaneous recovery interval even though conditioned magazine approach spontaneously recovered over this interval. Although extinction reduced the magnitude of PIT, the temporal expression of PIT was mostly unaffected. We found these effects in both male and female rats, though in 1 study females were extinction-resistant. These data suggest that under the conditions studied here Pavlovian extinction may permanently weaken the ability of Pavlovian cues to retrieve a representation of their associated outcomes without impacting the temporal organization of responding. This suggests that different features of learning may be differentially sensitive to extinction. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  3. Fire Extinguisher Training for Fire Watch and Designated Workers, Course 9893

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harris, Jimmy D.

    At Los Alamos National Laboratory (LANL), all workers must be aware of LANL fire protection policies and be trained on what to do in the event of a fire. This course, Fire Extinguisher Training for Fire Watch and Designated Workers (#9893), provides awareness-level and hands-on training for fire watch personnel and designated workers. Fire watch personnel and designated workers are appointed by line management and must receive both awareness-level training and hands-on training in the use of portable fire extinguishers to extinguish an incipient-stage fire. This training meets the requirements of the Occupational Safety and Health Administration (OSHA) Code ofmore » Federal Regulations (CFR) 29 CFR 1910.157, Portable Fire Extinguishers, and Procedure (P) 101-26, Welding, Cutting, and Other Spark-/Flame-Producing Operations.« less

  4. Fire Extinguisher Designated Worker and Fire Watch: Self-Study Course 15672

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harris, Jimmy D.

    At Los Alamos National Laboratory (LANL), all workers must be aware of LANL fire protection policies and be trained on what to do in the event of a fire. This course, Fire Extinguisher Training for Fire Watch and Designated Workers (#9893), provides awareness-level and hands-on training for fire watch personnel and designated workers. Fire watch personnel and designated workers are appointed by line management and must receive both awareness-level training and hands-on training in the use of portable fire extinguishers to extinguish an incipient-stage fire. This training meets the requirements of the Occupational Safety and Health Administration (OSHA) Code ofmore » Federal Regulations (CFR) 29 CFR 1910.157, Portable Fire Extinguishers, and Procedure (P) 101-26, Welding, Cutting, and Other Spark-/Flame-Producing Operations.« less

  5. Reliance on Simulation in Initial Entry Rifle Marksmanship Training and Future Directions for Simulation

    DTIC Science & Technology

    2016-11-01

    Engagement Simulation Training, and a day of dry -fire. The comparison was conducted during training with iron sights. On the two criterion measures, the...other five days of training consisted of two days of Engagement Skills Trainer (EST) 2000 training, one day of dry -fire, and two days of live-fire...0 / RM1 Preliminary Marksmanship Training Same as Baseline 1 / RM2 EST 2000 (grouping/zeroing) Test-D Drills 2 / RM3 Dry -Fire Training 25m Live-Fire

  6. Portfolio: Ceramics.

    ERIC Educational Resources Information Center

    Hardy, Jane; And Others

    1982-01-01

    Describes eight art activities using ceramics. Elementary students created ceramic tiles to depict ancient Egyptian and medieval European art, made ceramic cookie stamps, traced bisque plates on sketch paper, constructed clay room-tableaus, and designed clay relief masks. Secondary students pit-fired ceramic pots and designed ceramic Victorian…

  7. 10 CFR 1045.15 - Classification and declassification presumptions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... criteria in § 1045.16 indicates otherwise: (1) Basic science: mathematics, chemistry, theoretical and experimental physics, engineering, materials science, biology and medicine; (2) Magnetic confinement fusion...); (5) Fact of use of safety features (e.g., insensitive high explosives, fire resistant pits) to lower...

  8. 10 CFR 1045.15 - Classification and declassification presumptions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... criteria in § 1045.16 indicates otherwise: (1) Basic science: mathematics, chemistry, theoretical and experimental physics, engineering, materials science, biology and medicine; (2) Magnetic confinement fusion...); (5) Fact of use of safety features (e.g., insensitive high explosives, fire resistant pits) to lower...

  9. 29 CFR Appendix A to Subpart L of... - Fire Protection

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the International Fire Service Training Association, the National Fire Protection Association (NFPA-1041), the International Society of Fire Service Instructors and other fire training sources be... planning, and safety practices. It is again suggested that fire service training sources be consulted for...

  10. The effects of amphetamine sensitization on conditioned inhibition during a Pavlovian-instrumental transfer task in rats.

    PubMed

    Shiflett, Michael W; Riccie, Meaghan; DiMatteo, RoseMarie

    2013-11-01

    Psychostimulant sensitization heightens behavioral and motivational responses to reward-associated stimuli; however, its effects on stimuli associated with reward absence are less understood. We examined whether amphetamine sensitization alters performance during Pavlovian-instrumental transfer (PIT) to conditioned excitors and inhibitors. We further sought to characterize the effects of amphetamine sensitization on learning versus performance by exposing rats to amphetamine prior to Pavlovian training or between training and test. Adult male Long-Evans rats were given conditioned inhibition (A+/AX-) and Pavlovian (B+) training, followed by variable-interval instrumental conditioning. Rats were sensitized to D-amphetamine (2 mg/kg daily injections for 7 days) or served as non-exposed controls. Rats were given a PIT test, in which they were presented with stimulus B alone or in compound with the conditioned inhibitor (BX). During the PIT test, control rats significantly reduced instrumental responding on BX trials (to approximately 50 % of responding to B). Amphetamine sensitization prior to Pavlovian conditioning increased lever pressing on BX trials and reduced lever pressing on B trials compared to controls. Amphetamine sensitization between training and test increased lever pressing on B and BX trials compared to controls. No effects of sensitization were observed on conditioned food cup approach. Amphetamine sensitization increases instrumental responding during PIT to a conditioned inhibitor by enhancing the excitation of conditioned stimuli and reducing the inhibition of conditioned inhibitors.

  11. Technology and Organisation of Inka Pottery Production in the Leche Valley. Part II: Study of Fired Vessels

    NASA Astrophysics Data System (ADS)

    Hayashida, F.; Häusler, W.; Riederer, J.; Wagner, U.

    2003-09-01

    Ceramic finds from the Inka workshops at Tambo Real and La Viña in the Leche Valley in northern Peru were studied by Mössbauer spectroscopy, thin section microscopy and X-ray diffraction. Sherds of Inka style vessels and of local style vessels can be distinguished by their shape, although local techniques appear to have been used in making both types. A reconstruction of the firing techniques by scientific studies of the ceramic material does not reveal a substantial difference in material or in the firing of both forms, although high firing temperatures were necessary to achieve sufficient stability of the large Inka style vessels. It cannot be decided whether the smaller local vessels were fired together with the Inka vessels or separately. Most of the variation in the maximum firing temperature can be explained with the normal temperature and atmosphere fluctuations in an open pit kiln.

  12. Are we training pit bulls to review our manuscripts?

    PubMed

    Walbot, Virginia

    2009-01-01

    Good early training of graduate students and postdocs is needed to prevent them turning into future generations of manuscript-savaging reviewers. How can we intercalate typical papers into our training?

  13. Fire Problems in High-Rise Buildings. California Fire Service Training Program.

    ERIC Educational Resources Information Center

    California State Dept. of Education, Sacramento. Bureau of Industrial Education.

    Resulting from a conference concerned with high-rise fire problems, this manual has been prepared as a fire department training manual and as a reference for students enrolled in fire service training courses. Information is provided for topics dealing with: (1) Typical Fire Problems in High-Rise Buildings, (2) Heat, (3) Smoke and Fire Gases, (4)…

  14. Training Effectiveness Evaluation (TEE) of the Advanced Fire Fighting Training System. Focus on the Trained Person.

    ERIC Educational Resources Information Center

    Cordell, Curtis C.; And Others

    A training effectiveness evaluation of the Navy Advanced Fire Fighting Training System was conducted. This system incorporates simulated fires as well as curriculum materials and instruction. The fires are non-pollutant, computer controlled, and installed in a simulated shipboard environment. Two teams of 15 to 16 persons, with varying amounts of…

  15. Incipient I Fire Brigade Training & Certification.

    ERIC Educational Resources Information Center

    Anoka-Hennepin Technical Coll., Minneapolis, MN.

    This document contains course materials for the minimum general and Koch-specific requirements for the fire suppression training and education portion of the integrated industrial emergency response team training program. The various levels of performance were developed with the National Fire standard 600, Private Fire Brigades. The training is…

  16. Pit 9 Category of Transuranic Waste Stored Below Ground within Area G

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hargis, Kenneth M.

    2014-01-08

    A large wildfire called the Las Conchas Fire burned large areas near Los Alamos National Laboratory (LANL) in 2011 and heightened public concern and news media attention over transuranic (TRU) waste stored at LANL’s Technical Area 54 (TA-54) Area G waste management facility. The removal of TRU waste from Area G had been placed at a lower priority in budget decisions for environmental cleanup at LANL because TRU waste removal is not included in the March 2005 Compliance Order on Consent (Reference 1) that is the primary regulatory driver for environmental cleanup at LANL. The Consent Order is an agreementmore » between LANL and the New Mexico Environment Department (NMED) that contains specific requirements and schedules for cleaning up historical contamination at the LANL site. After the Las Conchas Fire, discussions were held by the U.S. Department of Energy (DOE) with the NMED on accelerating TRU waste removal from LANL and disposing it at the Waste Isolation Pilot Plant (WIPP).This report summarizes available information on the origin, configuration, and composition of the waste containers within Pit 9, their physical and radiological characteristics, and issues that may be encountered in their retrieval and processing. Review of the available information indicates that Pit 9 should present no major issues in retrieval and processing, and most drums contain TRU waste that can be shipped to WIPP. The primary concern in retrieval is the integrity of containers that have been stored below-ground for 35 to 40 years. The most likely issue that will be encountered in processing containers retrieved from Pit 9 is the potential for items that are prohibited at WIPP such as sealed containers greater than four liters in size and free liquids that exceed limits for WIPP.« less

  17. Physiological Ischemic Training Promotes Brain Collateral Formation and Improves Functions in Patients with Acute Cerebral Infarction.

    PubMed

    Zhen, Xiaoyue; Zheng, Yu; Hong, Xunning; Chen, Yan; Gu, Ping; Tang, Jinrong; Cheng, Hong; Yuan, Ti-Fei; Lu, Xiao

    2016-01-01

    To observe the effectiveness and mechanisms of physiological ischemic training (PIT) on brain cerebral collateral formation and functional recovery in patients with acute cerebral infarction. 20 eligible patients with acute cerebral infarction were randomly assigned to either PIT group ( n  = 10) or Control group ( n  = 10). Both groups received 4 weeks of routine rehabilitation therapy, while an additional session of PIT, which consisted of 10 times of maximal voluntary isometric handgrip for 1 min followed by 1 min rest, was prescribed for patients in the PIT groups. Each patient was trained with four sections a day and 5 days a week for 4 weeks. The Fugl-Meyer Assessment (FMA), the Modified Barthel Index (MBI), and the short-form 36-item health survey questionnaire (SF-36) were applied for the evaluation of motor impairment, activity of daily living, and quality of life at the baseline and endpoint. MRI was applied to detect the collateral formation in the brain. The concentration of vascular endothelial growth factor (VEGF) and endothelial progenitor cells (EPCs) number in plasma were also tested at the endpoint. Demographic data were consistent between experimental groups. At the endpoint, the scores of the FMA, MBI, and SF-36 were significantly higher than that at baseline. As compared to the Control group, the score of FMA and SF-36 in PIT group was significantly higher, while no significant difference was detected between groups in terms of MBI. Both groups had significantly higher cerebral blood flow (CBF) level at endpoint as compared to that at baseline. Moreover, the CBF level was even higher in the PIT group as compared to that in the Control group after 4 weeks of training. The same situations were also found in the plasma VEGF and EPCs assessment. In addition, positive correlations were found between FMA score and CBF level ( r  = 0.686, p  < 0.01), CBF level and VEGF concentration ( r  = 0.675, p  < 0.01), and VEGF concentration and EPC number ( r  = 0.722, p  < 0.01). PIT may be effective in increasing the expression of VEGF and recruitment of EPCs and in turn promote the formation of brain collateral circulation. The positive correlations may demonstrate a potential association between biological and functional parameters, and PIT may be able to improve the motor function, activity of daily living, and quality of life in patients with stroke.

  18. The effects of amphetamine sensitization on conditioned inhibition during a Pavlovian-instrumental transfer task in rats

    PubMed Central

    Shiflett, Michael W.; Riccie, Meaghan; DiMatteo, RoseMarie

    2013-01-01

    Rationale Psychostimulant sensitization heightens behavioral and motivational responses to reward-associated stimuli; however, its effects on stimuli associated with reward absence are less understood. Objectives We examined whether amphetamine sensitization alters performance during Pavlovian-instrumental transfer (PIT) to conditioned excitors and inhibitors. We further sought to characterize the effects of amphetamine sensitization on learning versus performance by exposing rats to amphetamine prior to Pavlovian training or between training and test. Methods Adult male Long Evans rats were given conditioned inhibition (A+/AX−) and Pavlovian (B+) training, followed by variable-interval instrumental conditioning. Rats were sensitized to d-amphetamine (2 mg/kg daily injections for seven days), or served as non-exposed controls. Rats were given a PIT test, in which they were presented with stimulus B alone or in compound with the conditioned inhibitor (BX). Results During the PIT test, control rats significantly reduced instrumental responding on BX trials (to approximately 50% of responding to B). Amphetamine sensitization prior to Pavlovian conditioning increased lever-pressing on BX trials and reduced lever-pressing on B trials compared to controls. Amphetamine sensitization between training and test increased lever-pressing on B and BX trials compared to controls. No effects of sensitization were observed on conditioned food-cup approach. Conclusions Amphetamine sensitization increases instrumental responding during PIT to a conditioned inhibitor, by enhancing excitation of conditioned stimuli and reducing inhibition of conditioned inhibitors. PMID:23715640

  19. Pottery from a Chimú Workshop Studied by Mössbauer Spectroscopy

    NASA Astrophysics Data System (ADS)

    Tschauner, H.; Wagner, U.

    2003-09-01

    Ceramic finds from a pottery workshop in the Lambayeque valley were studied by neutron activation analysis, Mössbauer spectroscopy and X-ray diffraction in an attempt to assess an advanced division of labour on the North Coast of Peru during the Chimú period (AD 1350-1460). The study suggests that the material was predominantly fired in a reducing environment with partial reoxidation at the end of the firing cycles, although firing in an oxidising atmosphere has taken place occasionally. The observed variation of firing conditions is characteristic for the use of pit kilns. The results of the archaeometric studies confirm the stylistic studies and show that pottery was no status symbol and far less important as a carrier of Chimú style than metal artefacts.

  20. Changes in the Influence of Alcohol-Paired Stimuli on Alcohol Seeking across Extended Training

    PubMed Central

    Corbit, Laura H.; Janak, Patricia H.

    2016-01-01

    Previous work has demonstrated that goal-directed control of alcohol-seeking and other drug-related behaviors is reduced following extended self-administration and drug exposure. Here, we examined how the magnitude of stimulus influences on responding changes across similar training and drug exposure. Rats self-administered alcohol or sucrose for 2 or 8 weeks. Previous work has shown that 8 weeks, but not 2 weeks of self-administration produces habitual alcohol seeking. Next, all animals received equivalent Pavlovian conditioning sessions where a discrete stimulus predicted the delivery of alcohol or sucrose. Finally, the impact of the stimuli on ongoing instrumental responding was examined in a Pavlovian–instrumental transfer (PIT) test. While a significant PIT effect was observed following 2 weeks of either alcohol or sucrose self-administration, the magnitude of this effect was greater following 8 weeks of training. The specificity of the PIT effect appeared unchanged by extended training. While it is well established that evaluation of the outcome of responding contributes less to behavioral control following extended training and/or drug exposure, our data indicate that reward–predictive stimuli have a stronger contribution to responding after extended training. Together, these findings provide insight into the factors that control behavior after extended drug use, which will be important for developing effective methods for controlling and ideally reducing these behaviors. PMID:27777560

  1. Safewalk: Improving Enrichment and Adoption Rates for Shelter Dogs by Changing Human Behavior.

    PubMed

    Bright, Terri M; Hadden, Louise

    2017-01-01

    Shelter dogs are typically cared for by staff and volunteers. At the Boston location of the Massachusetts Society for the Prevention of Cruelty to Animals, prior to 2009, any member of the public who was older than 16 years of age and attended 1 orientation could walk dogs available for adoption. There was no systematic method of training volunteers or staff to walk unruly, strong, or fearful dogs, nor was there any organized system of enrichment in the form of in-kennel or out-of-kennel training for the population of 20 to 40 dogs in the shelter. Using the Dick and Carey ( 1996 ) model of instructional design, a curriculum called "Safewalk" was devised and implemented. Safewalk created a hierarchical training system for volunteers. After training was implemented, outcomes and lengths of stay were then compared for dogs for the 3 years before and 4 years after Safewalk. Changes in adoption rates for pit bull-type dogs and non-pit bulls were significantly improved, and length of stay for non-pit bulls was significantly decreased. Other components of shelter life for dogs and people were also improved.

  2. OR fire virtual training simulator: design and face validity.

    PubMed

    Dorozhkin, Denis; Olasky, Jaisa; Jones, Daniel B; Schwaitzberg, Steven D; Jones, Stephanie B; Cao, Caroline G L; Molina, Marcos; Henriques, Steven; Wang, Jinling; Flinn, Jeff; De, Suvranu

    2017-09-01

    The Virtual Electrosurgical Skill Trainer is a tool for training surgeons the safe operation of electrosurgery tools in both open and minimally invasive surgery. This training includes a dedicated team-training module that focuses on operating room (OR) fire prevention and response. The module was developed to allow trainees, practicing surgeons, anesthesiologist, and nurses to interact with a virtual OR environment, which includes anesthesia apparatus, electrosurgical equipment, a virtual patient, and a fire extinguisher. Wearing a head-mounted display, participants must correctly identify the "fire triangle" elements and then successfully contain an OR fire. Within these virtual reality scenarios, trainees learn to react appropriately to the simulated emergency. A study targeted at establishing the face validity of the virtual OR fire simulator was undertaken at the 2015 Society of American Gastrointestinal and Endoscopic Surgeons conference. Forty-nine subjects with varying experience participated in this Institutional Review Board-approved study. The subjects were asked to complete the OR fire training/prevention sequence in the VEST simulator. Subjects were then asked to answer a subjective preference questionnaire consisting of sixteen questions, focused on the usefulness and fidelity of the simulator. On a 5-point scale, 12 of 13 questions were rated at a mean of 3 or greater (92%). Five questions were rated above 4 (38%), particularly those focusing on the simulator effectiveness and its usefulness in OR fire safety training. A total of 33 of the 49 participants (67%) chose the virtual OR fire trainer over the traditional training methods such as a textbook or an animal model. Training for OR fire emergencies in fully immersive VR environments, such as the VEST trainer, may be the ideal training modality. The face validity of the OR fire training module of the VEST simulator was successfully established on many aspects of the simulation.

  3. Fire training in a virtual-reality environment

    NASA Astrophysics Data System (ADS)

    Freund, Eckhard; Rossmann, Jurgen; Bucken, Arno

    2005-03-01

    Although fire is very common in our daily environment - as a source of energy at home or as a tool in industry - most people cannot estimate the danger of a conflagration. Therefore it is important to train people in combating fire. Beneath training with propane simulators or real fires and real extinguishers, fire training can be performed in virtual reality, which means a pollution-free and fast way of training. In this paper we describe how to enhance a virtual-reality environment with a real-time fire simulation and visualisation in order to establish a realistic emergency-training system. The presented approach supports extinguishing of the virtual fire including recordable performance data as needed in teletraining environments. We will show how to get realistic impressions of fire using advanced particle-simulation and how to use the advantages of particles to trigger states in a modified cellular automata used for the simulation of fire-behaviour. Using particle systems that interact with cellular automata it is possible to simulate a developing, spreading fire and its reaction on different extinguishing agents like water, CO2 or oxygen. The methods proposed in this paper have been implemented and successfully tested on Cosimir, a commercial robot-and VR-simulation-system.

  4. δ-Opioid and Dopaminergic Processes in Accumbens Shell Modulate the Cholinergic Control of Predictive Learning and Choice

    PubMed Central

    Laurent, Vincent; Bertran-Gonzalez, Jesus; Chieng, Billy C.

    2014-01-01

    Decision-making depends on the ability to extract predictive information from the environment to guide future actions. Outcome-specific Pavlovian-instrumental transfer (PIT) provides an animal model of this process in which a stimulus predicting a particular outcome biases choice toward actions earning that outcome. Recent evidence suggests that cellular adaptations of δ-opioid receptors (DORs) on cholinergic interneurons (CINs) in the nucleus accumbens shell (NAc-S) are necessary for PIT. Here we found that modulation of DORs in CINs critically influences D1-receptor (D1R)-expressing projection neurons in the NAc-S to promote PIT. First, we assessed PIT-induced changes in signaling processes in dopamine D1- and D2-receptor-expressing neurons using drd2-eGFP mice, and found that PIT-related signaling was restricted to non-D2R-eGFP-expressing neurons, suggesting major involvement of D1R-neurons. Next we confirmed the role of D1Rs pharmacologically: the D1R antagonist SCH-23390, but not the D2R antagonist raclopride, infused into the NAc-S abolished PIT in rats, an effect that depended on DOR activity. Moreover, asymmetrical infusion of SCH-23390 and the DOR antagonist naltrindole into the NAc-S also abolished PIT. DOR agonists were found to sensitize the firing responses of CINs in brain slices prepared immediately after the PIT test. We confirmed the opioid-acetylcholinergic influence over D1R-neurons by selectively blocking muscarinic M4 receptors in the NAc-S, which tightly regulate the activity of D1Rs, a treatment that rescued the deficit in PIT induced by naltrindole. We describe a model of NAc-S function in which DORs modulate CINs to influence both D1R-neurons and stimulus-guided choice between goal-directed actions. PMID:24453326

  5. Environmental Assessment. Proposed Sahara Mustard Control on the Barry M. Goldwater Range - East

    DTIC Science & Technology

    2012-02-01

    While some sites consist of only a few artifacts or a single archaeological feature such as a trail or a hearth ; others cover a large area and...such as hearths , roasting pits, and fire-affected rock, cleared areas or sleeping circles, linear and circular rock alignments, rock cairns, trails

  6. The Coast Artillery Journal. Volume 58, Number 2, February 1923

    DTIC Science & Technology

    1923-02-01

    firing mechanism block with a fresh primer in place. No.5 acted as a powder runner between the powder pit and No.2. Nos. 6 and 7 carried the loading...obstruct these routes. Xumerous passive obstructions have been conceived: metallic cables raised and maintained in the air by kites ; cables shot into the

  7. Engagement Skills Trainer: The Commander’s Perspective

    DTIC Science & Technology

    2017-06-09

    recommends using EST as a record of fire for a sustainment training event . This record of fire event can only occur once per year and after a live fire...mandatory part of marksmanship training. The author also recommends using EST as a record of fire for a sustainment training event . This record of fire... event can only occur once per year and after a live fire qualification. v ACKNOWLEDGMENTS The author would like to thank the following persons

  8. Physiologic ischaemic training induces endothelial progenitor cell mobilization and myocardial angiogenesis via endothelial nitric oxide synthase related pathway in rabbits.

    PubMed

    Xiao, Mingyue; Lu, Xiao; Li, Jianan; Li, Ling; Li, Yongxue

    2014-04-01

    Ischaemia-induced angiogenesis promises to improve neovascularization by delivery of angiogenic factors or endothelial progenitor cells (EPCs) to cardiac ischaemic areas. In order to avoid the risk of excessive myocardial ischaemia, therefore, we hypothesized that physiological ischaemic training (PIT) of normal skeletal muscle might contribute to myocardial angiogenesis via nitric oxide mediated mobilization of EPCs from the bone marrow in the established rabbit model of controllable myocardial ischaemia. The rabbits were grouped by sham-operation, myocardial ischaemia without PIT, PIT and PIT with pretreatment with the endothelial nitric oxide synthase (eNOS) inhibitor L-nitroarginine methyl ester (L-NAME). Controlled myocardial ischaemia was modelled by a water balloon constrictor implanted on the left ventricular branch in a rabbit. The PIT procedure included three cycles of 3 min of cuff inflation followed by 5 min of deflation on hind limbs of the rabbits for 4 weeks. At the endpoints, circulating EPCs (CD34/Flk-1) were measured by fluorescence-activated cell sorter; capillary density, by immunohistochemistry; blood flow, by a microsphere technique; endothelial nitric oxide synthase (eNOS) mRNA and protein, by real-time reverse transcriptase (RT)-PCR and Western blotting. The mRNA levels of eNOS were significantly higher in the PIT and L-NAME groups than in the sham-operation group (P < 0.05). Phospho-eNOS protein expression was higher in the PIT group than in the sham-operation and myocardial ischaemia without PIT groups (P < 0.05), and the effect was inhibited by L-NAME pretreatment (P < 0.05). Compared with sham-operation and myocardial ischaemia without PIT groups, the PIT group had the highest EPC count (P < 0.001), and the increase of capillary density (P < 0.01) and collateral blood flow (P < 0.05) in the ischaemic myocardium was consistent with the finding of EPC count. These effects were also inhibited by pretreatment with the eNOS inhibitor L-NAME. Capillary density and collateral blood flow were highly correlated with the increase of EPC count (r = 0.913 and r = 0.929, respectively, P = 0.000). PIT improved EPC mobilization and contributed to compensatory neovascularization via eNOS-related pathway. These results might support the future development of strategies for therapeutic neovascularization.

  9. Investigation of Formative Assessment of Learning (INFORMAL): The Performance Indicator Tool (PIT)

    ERIC Educational Resources Information Center

    Dutton, Philip J.; Bickerstaff, Helen E.; Rymer, Janice M.; Webb, Mary E.; Ballinger-Mills, Deborah; Greenough, Anne; Reynolds, Patricia A.

    2017-01-01

    This pilot study evaluated the student user experience of a performance indicator tool (PIT) for formative assessment of a cohort of fourth year medical undergraduates undertaking a 12 week rotation. Scoping and elaboration for the standalone web-based tool was based on the existing paper-based formative assessment system for which training and…

  10. 46 CFR 185.524 - Fire fighting drills and training.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Fire fighting drills and training. 185.524 Section 185... 100 GROSS TONS) OPERATIONS Preparations for Emergencies § 185.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar...

  11. 46 CFR 185.524 - Fire fighting drills and training.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Fire fighting drills and training. 185.524 Section 185... 100 GROSS TONS) OPERATIONS Preparations for Emergencies § 185.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar...

  12. 46 CFR 185.524 - Fire fighting drills and training.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Fire fighting drills and training. 185.524 Section 185... 100 GROSS TONS) OPERATIONS Preparations for Emergencies § 185.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar...

  13. 46 CFR 185.524 - Fire fighting drills and training.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Fire fighting drills and training. 185.524 Section 185... 100 GROSS TONS) OPERATIONS Preparations for Emergencies § 185.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar...

  14. 46 CFR 185.524 - Fire fighting drills and training.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Fire fighting drills and training. 185.524 Section 185... 100 GROSS TONS) OPERATIONS Preparations for Emergencies § 185.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar...

  15. 77 FR 70172 - Lifesaving and Fire-Fighting Equipment, Training and Drills Onboard Offshore Facilities and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-23

    ... Equipment, Training and Drills Onboard Offshore Facilities and Mobile Offshore Drilling Units (MODUs... lifesaving and fire-fighting equipment, training and drills on board offshore facilities and MODUs operating... guidance concerning lifesaving and fire-fighting equipment, training, and drills onboard manned offshore...

  16. Design and Realization of Ship Fire Simulation Training System Based on Unity3D

    NASA Astrophysics Data System (ADS)

    Ting, Ye; Feng, Chen; Wenqiang, Wang; Kai, Yang

    2018-01-01

    Ship fire training is a very important training to ensure the safety of the ship, but limited by the characteristics of the ship itself, it is difficult to carry out fire training on the ship. This paper proposes to introduce a virtual reality technology to build a set of ship fire simulation training system, used to improve the quality of training, reduce training costs. First, the system design ideas are elaborated, and the system architecture diagram is given. Then, the key technologies in the process of system implementation are analyzed. Finally, the system examples are built and tested.

  17. The Relationship Between Specific Pavlovian Instrumental Transfer and Instrumental Reward Probability

    PubMed Central

    Cartoni, Emilio; Moretta, Tania; Puglisi-Allegra, Stefano; Cabib, Simona; Baldassarre, Gianluca

    2015-01-01

    Goal-directed behavior is influenced by environmental cues: in particular, cues associated with a reward can bias action choice toward actions directed to that same reward. This effect is studied experimentally as specific Pavlovian-instrumental transfer (specific PIT). We have investigated the hypothesis that cues associated to an outcome elicit specific PIT by rising the estimates of reward probability of actions associated to that same outcome. In other words, cues reduce the uncertainty on the efficacy of instrumental actions. We used a human PIT experimental paradigm to test the effects of two different instrumental contingencies: one group of participants had a 33% chance of being rewarded for each button press, while another had a 100% chance. The group trained with 33% reward probability showed a stronger PIT effect than the 100% group, in line with the hypothesis that Pavlovian cues linked to an outcome work by reducing the uncertainty of receiving it. The 100% group also showed a significant specific PIT effect, highlighting additional factors that could contribute to specific PIT beyond the instrumental training contingency. We hypothesize that the uncertainty about reward delivery due to testing in extinction might be one of these factors. These results add knowledge on how goal-directed behavior is influenced by the presence of environmental cues associated with a reward: such influence depends on the probability that we have to reach a reward, namely when there is less chance of getting a reward we are more influenced by cues associated with it, and vice versa. PMID:26635645

  18. 46 CFR 122.524 - Fire fighting drills and training.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Fire fighting drills and training. 122.524 Section 122... Preparations for Emergencies § 122.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a...

  19. 46 CFR 122.524 - Fire fighting drills and training.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Fire fighting drills and training. 122.524 Section 122... Preparations for Emergencies § 122.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a...

  20. 46 CFR 122.524 - Fire fighting drills and training.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Fire fighting drills and training. 122.524 Section 122... Preparations for Emergencies § 122.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a...

  1. 46 CFR 122.524 - Fire fighting drills and training.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Fire fighting drills and training. 122.524 Section 122... Preparations for Emergencies § 122.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a...

  2. 46 CFR 122.524 - Fire fighting drills and training.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Fire fighting drills and training. 122.524 Section 122... Preparations for Emergencies § 122.524 Fire fighting drills and training. (a) The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a...

  3. Maryland Fire-Rescue Education and Training System. Organizational Design.

    ERIC Educational Resources Information Center

    Maryland Fire-Rescue Education and Training Commission.

    This is a description of the Maryland system which was created to evaluate local fire-rescue education and training needs and capabilities and to assist local authorities with fire-rescue education and training. In the first of four parts, an historical presentation is used to identify and describe in general terms the state fire, rescue, and…

  4. Installation Restoration Program. Phase 1. Records Search, Kelly AFB, Texas

    DTIC Science & Technology

    1982-02-01

    1000-1500 gallons per year based on two training sessions per year. The ultimate BOD of AFFF ( FC -780B, manufactured by 3M) is 370,000 mg/l in...Landfill 1917-1942 44 24 FC -i Fire Control Training Area ?-1950’s 42 25 FC -2 Fire Control Training Area 1950’s-1981 41 26 RD-i Radioactive Disposal Area...were buried had very short half-lifes. This site received a low score of 45. 6) Fire Control Training Areas a. The Fire Control Training Areas FC -I and

  5. Is the ipsilateral cortex surrounding the lesion or the non-injured contralateral cortex important for motor recovery in rats with photochemically induced cortical lesions?

    PubMed

    Takata, Kotaro; Yamauchi, Hideki; Tatsuno, Hisashi; Hashimoto, Keiji; Abo, Masahiro

    2006-01-01

    To determine whether the ipsilateral cortex surrounding the lesion or the non-injured contralateral cortex is important for motor recovery after brain damage in the photochemically initiated thrombosis (PIT) model. We induced PIT in the sensorimotor cortex in rats and examined the recovery of motor function using the beam-walking test. In 24 rats, the right sensorimotor cortex was lesioned after 2 days of training for the beam-walking test (group 1). After 10 days, PIT was induced in the left sensorimotor cortex. Eight additional rats (group 2) received 2 days training in beam walking, then underwent the beam-walking test to evaluate function. After 10 days of testing, the left sensorimotor cortex was lesioned and recovery was monitored by the beam-walking test for 8 days. In group 1 animals, left hindlimb function caused by a right sensorimotor cortex lesion recovered within 10 days after the operation. Right hindlimb function caused by the left-side lesion recovered within 6 days. In group 2, right hindlimb function caused by induction of the left-side lesion after a total of 12 days of beam-walking training and testing recovered within 6 days as with the double PIT model. The training effect may be relevant to reorganization and neuromodulation. Motor recovery patterns did not indicate whether motor recovery was dependent on the ipsilateral cortex surrounding the lesion or the cortex of the contralateral side. The results emphasize the need for selection of appropriate programs tailored to the area of cortical damage in order to enhance motor functional recovery in this model. Copyright 2006 S. Karger AG, Basel.

  6. 40 CFR 60.3062 - What is an air curtain incinerator?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... curtain of air across an open, integrated combustion chamber (fire box) or open pit or trench (trench... 40 Protection of Environment 6 2011-07-01 2011-07-01 false What is an air curtain incinerator? 60... Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3062 What is...

  7. Three-phase foam analysis and development of a lab-scale foaming capacity and stability test for swine manure

    USDA-ARS?s Scientific Manuscript database

    Foam accumulation on the manure slurry at deep pit swine facilities has been linked to flash fire incidents, making it a serious safety concern for pork producers. In order to investigate this phenomenon, samples of swine manure were collected from over 50 swine production facilities in Iowa with va...

  8. Training and Education in the Fire Services (Proceedings of a Symposium, April 8-9 1970).

    ERIC Educational Resources Information Center

    National Academy of Sciences-National Research Council, Washington, DC. Div. of Engineering.

    Issues in the improvement of training for fire fighters and officer personnel were taken up in ten symposium papers. Session I covered legal and other constraints that affect what a fire fighter should know; and current practices in volunteer, rural, and municipal fire fighter training in the United States. Papers from the other sessions dealt…

  9. Algorithms for detecting cherry pits on the basis of transmittance mode hyperspectral data

    NASA Astrophysics Data System (ADS)

    Siedliska, Anna; Zubik, Monika; Baranowski, Piotr; Mazurek, Wojciech

    2017-10-01

    The suitability of the hyperspectral transmittance imaging technique was assessed in terms of detecting the internal intrusions (pits and their fragments) in cherries. Herein, hyperspectral transmission images were acquired in the visible and near-infrared range (450-1000 nm) from pitted and intact cherries of three popular cultivars: `Łutówka', `Pandy 103', and `Groniasta', differing by soluble solid content. The hyperspectral transmittance data of fresh cherries were used to determine the influence of differing soluble solid content in fruit tissues on pit detection effectiveness. Models for predicting the soluble solid content of cherries were also developed. The principal component analysis and the second derivative pre-treatment of the hyperspectral data were used to construct the supervised classification models. In this study, five classifiers were tested for pit detection. From all the classifiers studied, the best prediction accuracies for the whole pit or pit fragment detection were obtained via the backpropagation neural networks model (87.6% of correctly classified instances for the training/test set and 81.4% for the validation set). The accuracy of distinguishing between drilled and intact cherries was close to 96%. These results showed that the hyperspectral transmittance imaging technique is feasible and useful for the non-destructive detection of pits in cherries.

  10. No Further Action Decision Under CERCLA, Study Area 31, Moore Army Airfield Fire Fighting Training Area, Fort Devens, Massachusetts

    DTIC Science & Technology

    1995-01-01

    FURTHER ACTION DECISION UNDER CERCLAI STUDY AREA 31 MOORE ARMY AIRFIELD FIRE FIGHTING TRAINING AREA FORT DEVENS , MASSACHUSETFS TABLE OF CONTENTS jSection...Inc. 31DD.DOC 6917.11 111,, NO FURTHER ACTION DECISION UNDER CERCLA I STUDY AREA 31 MOORE ARMY AIRFIELD FIRE FIGHTING TRAINING AREA 3 FORT DEVENS ...Fire Fighting Training Area) at Fort Devens , Massachusetts, have resulted in the decision that no further studies or remediation are required at this

  11. Water in Fire Control--Basic Training Course.

    ERIC Educational Resources Information Center

    Forest Service (USDA), Washington, DC.

    Prepared by a team of fire control officers, the training guide is designed to help fire crewmen learn the fundamentals of water use. The entire package can be used for a complete course or individual lessons and can be adapted to specific training needs. Throughout the guide, emphasis is placed on one primary training objective, performance in…

  12. Establishing Fire Safety Skills Using Behavioral Skills Training

    ERIC Educational Resources Information Center

    Houvouras, Andrew J., IV; Harvey, Mark T.

    2014-01-01

    The use of behavioral skills training (BST) to educate 3 adolescent boys on the risks of lighters and fire setting was evaluated using in situ assessment in a school setting. Two participants had a history of fire setting. After training, all participants adhered to established rules: (a) avoid a deactivated lighter, (b) leave the training area,…

  13. Training Fires on Indian Reservations in Idaho, Oregon, and Washington

    EPA Pesticide Factsheets

    The Federal Air Rules for Reservations (FARR) Open Burning Rule allows Fire Protection Services to request permission from EPA to conduct an outdoor burn by qualified personnel to train firefighters on fire suppression and fire fighting techniques.

  14. FIRE SERVICE TRAINING, INSTRUCTOR'S MANUAL, BASIC COURSE.

    ERIC Educational Resources Information Center

    BERNDT, WILLIAM M.; AND OTHERS

    INSTRUCTORS CAN USE THIS MANUAL IN CONDUCTING A 34-HOUR FIRE STATION OR TRAINING CENTER EXTENSION PROGRAM TO IMPROVE THE COMPETENCIES AND SKILLS OF LOCAL FIRE PERSONNEL IN THE SPECIALIZED FIELD OF FIRE SERVICE. IT WAS DEVELOPED BY A STATEWIDE COMMITTEE OF FIRE FIGHTING CONSULTANTS AND ADVISORY GROUPS. THE 26 TEACHING GUIDES PROVIDE INSTRUCTIONAL…

  15. Applying Open Source Game Engine for Building Visual Simulation Training System of Fire Fighting

    NASA Astrophysics Data System (ADS)

    Yuan, Diping; Jin, Xuesheng; Zhang, Jin; Han, Dong

    There's a growing need for fire departments to adopt a safe and fair method of training to ensure that the firefighting commander is in a position to manage a fire incident. Visual simulation training systems, with their ability to replicate and interact with virtual fire scenarios through the use of computer graphics or VR, become an effective and efficient method for fire ground education. This paper describes the system architecture and functions of a visual simulated training system of fire fighting on oil storage, which adopting Delat3D, a open source game and simulation engine, to provide realistic 3D views. It presents that using open source technology provides not only the commercial-level 3D effects but also a great reduction of cost.

  16. Preparedness of fire safety in underground train station: Comparison between train operators in Malaysia with other operators from the developed countries

    NASA Astrophysics Data System (ADS)

    Tajedi, Noor Aqilah A.; Sukor, Nur Sabahiah A.; Ismail, Mohd Ashraf M.; Shamsudin, Shahrul A.

    2017-10-01

    The purpose of this paper is to compare the fire evacuation plan and preparation at the underground train stations in the different countries. The methodology for this study was using the extended questionnaire survey to investigate the Rapid Rail Sdn Bhd, Malaysia's fire safety plan and preparation at the underground train stations. There were four sections in the questionnaire which included (i) background of the respondents, (ii) the details on the train stations, safety instruction and fire evacuation exercises (iii) technical systems, installation and equipment at the underground stations and (iv) procedures and technical changes related to fire safety that had been applied by the operators. Previously, the respondents from the different train operator services in the developed countries had completed the questionnaires. This paper extends the response from the Rapid Rail Sdn Bhd to compare the emergency procedures and preparation for fire event with the developed countries. As a result, this study found that the equipment and facilities that provided at the underground train stations that operated by Rapid Rail are relevant for fire safety procedures and needs. The main advantage for Rapid Rail is the underground stations were designed with two or more entrances/exits that may perform better evacuation compare to one main entrance/exit train stations in the other developed countries.

  17. The Effect of Computer-Based Simulation Training on Fire Ground Incident Commander Decision Making

    ERIC Educational Resources Information Center

    Hall, Kurt A.

    2010-01-01

    Since the establishment of the first volunteer fire brigades in the United States, firefighters have lost their lives in fire fighting operations at emergency incidents and live-fire training activities. While there are various reasons for these firefighter deaths and injuries, the United States Fire Administration (2002) reported that many of…

  18. First Responder Immersive Training Environment (FRITSE): Development of a Games-Based Simulator for CBRN First Responder Training

    DTIC Science & Technology

    2014-11-01

    SV © Her Majesty the Queen in Right of Canada, as represented by the Minister of National Defence, 2014 © Sa Majesté la Reine (en droit du Canada... dragged over to fire hydrants to be attached to the steamer caps. Bolt cutters can be used to cut holes in fences allowing better access to the train...derailment fire. Ground monitors (for blitz fire) can be positioned for fire attack. 65mm attack lines can be dragged from fire engines and

  19. 28. VIEW OF BOILER 901 (IS IT 900?) AT GROUND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    28. VIEW OF BOILER 901 (IS IT 900?) AT GROUND LEVEL. INSTALLED IN 1928 IT WAS FIRED WITH PULVERIZED COAL. THE PULVERIZERS ARE LOCATED TO THE LEFT AND RIGHT OF THE CENTER ASH PIT ACCESS, BELOW THE CIRCULAR AIR INTAKES. THE PULVERIZED ON THE LEFT WAS POWERED WITH AN ELECTRIC MOTOR WHILE THE UNIT ON THE RIGHT WAS DRIVEN BY A STEAM TURBINE. THE HOPPER (TOP CENTER) WAS FILLED VIA A LARRY CAR WHICH RODE ON TRACKS SUSPENDED ABOVE THE FIRING AISLE. THIS BOILER WAS SHUT DOWN IN 1957. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT

  20. Lead Exposure in Military Outdoor Firing Ranges.

    PubMed

    Greenberg, Nili; Frimer, Ron; Meyer, Robert; Derazne, Estella; Chodick, Gabrial

    2016-09-01

    Several studies have reported significant airborne lead exposures during training at indoor firing ranges. Scarce attention has been given to airborne lead exposures in outdoor shooting ranges with automatic weapons. To assess the prevalence and magnitude of airborne and blood lead levels (BLL) among firing instructors and shooters in military outdoor ranges. Exposure assessment, for both trainees and instructors, included airborne and BLL during basic and advanced training at outdoor firing ranges. Personal airborne samples were collected in both day and night shooting during both training periods. During basic training, there is 95% likelihood that up to 25% of instructors and 99% likelihood that up to 5% of trainees might be exposed above the action level (AL) (25 μg/m(3)). During advanced training, there is 90% likelihood that 10% of instructors and 99% likelihood that up to 10% of trainees might be exposed above the AL. Military personnel participating in automatic weapon marksmanship training can be exposed to considerable levels of airborne lead during outdoor firing range training. As a result, the Israel Defense Force Medical Corp has classified firing range instructors as workers that require periodic medical examinations. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  1. 29 CFR Appendix A to Subpart L of... - Fire Protection

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., amount, and frequency of training and education will be as varied as are the purposes for which fire... should be qualified to train fire brigade members and demonstrate skills in communication, methods of... situations including “wet drills” and, when feasible, extinguishment of actual mock fires. Frequency of...

  2. 29 CFR Appendix A to Subpart L of... - Fire Protection

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., amount, and frequency of training and education will be as varied as are the purposes for which fire... should be qualified to train fire brigade members and demonstrate skills in communication, methods of... situations including “wet drills” and, when feasible, extinguishment of actual mock fires. Frequency of...

  3. 29 CFR Appendix A to Subpart L of... - Fire Protection

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., amount, and frequency of training and education will be as varied as are the purposes for which fire... should be qualified to train fire brigade members and demonstrate skills in communication, methods of... situations including “wet drills” and, when feasible, extinguishment of actual mock fires. Frequency of...

  4. 29 CFR Appendix A to Subpart L of... - Fire Protection

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., amount, and frequency of training and education will be as varied as are the purposes for which fire... should be qualified to train fire brigade members and demonstrate skills in communication, methods of... situations including “wet drills” and, when feasible, extinguishment of actual mock fires. Frequency of...

  5. 49 CFR 193.2717 - Training: fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... under § 193.2801. (b) A written plan of continuing instruction, including plant fire drills, must be... 49 Transportation 3 2013-10-01 2013-10-01 false Training: fire protection. 193.2717 Section 193...: fire protection. (a) All personnel involved in maintenance and operations of an LNG plant, including...

  6. 49 CFR 193.2717 - Training: fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... under § 193.2801. (b) A written plan of continuing instruction, including plant fire drills, must be... 49 Transportation 3 2011-10-01 2011-10-01 false Training: fire protection. 193.2717 Section 193...: fire protection. (a) All personnel involved in maintenance and operations of an LNG plant, including...

  7. 49 CFR 193.2717 - Training: fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... under § 193.2801. (b) A written plan of continuing instruction, including plant fire drills, must be... 49 Transportation 3 2012-10-01 2012-10-01 false Training: fire protection. 193.2717 Section 193...: fire protection. (a) All personnel involved in maintenance and operations of an LNG plant, including...

  8. 49 CFR 193.2717 - Training: fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... under § 193.2801. (b) A written plan of continuing instruction, including plant fire drills, must be... 49 Transportation 3 2014-10-01 2014-10-01 false Training: fire protection. 193.2717 Section 193...: fire protection. (a) All personnel involved in maintenance and operations of an LNG plant, including...

  9. An assessment of air quality impacts of fires associated with fire fighting operations.

    PubMed

    Leahey, D M; Hansen, M C; Schroeder, M B

    1993-03-01

    Fire fighters in Canada's navy must undergo regular training with fires from simulated helicopter crashes. Visible emissions from these fires often create health concerns in surrounding communities. This paper presents air quality implications of plume dispersion associated with "helicopter fires." Evaluations involved measuring plume rise, estimating emissions, dispersion modeling and ambient monitoring. Results of the evaluation provided ground-level concentration estimates of plume particulate matter, oxides of nitrogen, hydrogen fluoride, carbon monoxide, 22 metals, 15 PAH and 13 VOC. The study showed that the air quality impact of the fire fighting training is much lower than the relevant time-weighted averages established to protect workers' health. This paper will be of interest to people in environmental protection agencies because it demonstrates the effects of fire fighting operations that must frequently occur as part of training exercises.

  10. Effects of barbell deadlift training on submaximal motor unit firing rates for the vastus lateralis and rectus femoris.

    PubMed

    Stock, Matt S; Thompson, Brennan J

    2014-01-01

    Previous investigations that have studied motor unit firing rates following strength training have been limited to small muscles, isometric training, or interventions involving exercise machines. We examined the effects of ten weeks of supervised barbell deadlift training on motor unit firing rates for the vastus lateralis and rectus femoris during a 50% maximum voluntary contraction (MVC) assessment. Twenty-four previously untrained men (mean age  = 24 years) were randomly assigned to training (n = 15) or control (n = 9) groups. Before and following the intervention, the subjects performed isometric testing of the right knee extensors while bipolar surface electromyographic signals were detected from the two muscles. The signals were decomposed into their constituent motor unit action potential trains, and motor units that demonstrated accuracy levels less than 92.0% were not considered for analysis. One thousand eight hundred ninety-two and 2,013 motor units were examined for the vastus lateralis and rectus femoris, respectively. Regression analyses were used to determine the linear slope coefficients (pulses per second [pps]/% MVC) and y-intercepts (pps) of the mean firing rate and firing rate at recruitment versus recruitment threshold relationships. Deadlift training significantly improved knee extensor MVC force (Cohen's d = .70), but did not influence force steadiness. Training had no influence on the slopes and y-intercepts for the mean firing rate and firing rate at recruitment versus recruitment threshold relationships. In agreement with previous cross-sectional comparisons and randomized control trials, our findings do not support the notion that strength training affects the submaximal control of motor units.

  11. Your Fire Department. Organization--Recruitment--Equipment--Training. Revised.

    ERIC Educational Resources Information Center

    Pribyl, Paul F.

    This publication is intended as a guide in the organization, staffing, equipping, and training of fire departments in Wisconsin. A separate section focuses on each of these four areas. The first section discusses an ordinance to create a fire department, qualifications and authority of the fire chief, and an outline of duties and responsibilities…

  12. Model Training Guide. Firefighter I.

    ERIC Educational Resources Information Center

    Hagevig, William A.; Gallagher, Leigh S.

    This firefighter training guide for a 180-hour course was developed to assist training officers in planning training with emphasis on conformance to recommended National Fire Protection Association (NFPA 1001) standards. The material in the guide is referenced to current editions of the International Fire Service Training Association manuals and…

  13. The effects of amphetamine exposure on outcome-selective Pavlovian-instrumental transfer in rats

    PubMed Central

    Shiflett, Michael W.

    2012-01-01

    Rationale Repeated exposure to psychostimulants alters behavioral responses to reward-related cues; however, the motivational underpinnings of this effect have not been fully characterized. Objectives The following study was designed to examine how amphetamine sensitization affects performance in rats on a series of Pavlovian and operant tasks that distinguish between general-incentive and outcome-selective forms of conditioned responses. Methods Adult male rats underwent Pavlovian and instrumental training for food pellet rewards. Following training, rats were sensitized to d-amphetamine (2 mg/kg for 7 days). Rats were subsequently tested on an outcome-selective Pavlovian-instrumental transfer (PIT) task, an outcome-reinstatement task, and an outcome devaluation task. Additionally, in a separate experiment PIT was assessed in amphetamine-sensitized and control rats using a Pavlovian backward-conditioned stimulus. Results Repeated amphetamine exposure sensitized locomotor activity to acute amphetamine challenge. Amphetamine altered responses to CS presentations by increasing conditioned approach. During tests of PIT amphetamine-treated rats showed no outcome-selectivity in their responding, responding to a CS whether or not it shared a common outcome with the instrumental response. No effect of amphetamine sensitization was observed on tests of outcome-selective reinstatement by outcome delivery, or action selection based on outcome value. Amphetamine-sensitized rats showed impaired outcome-selective PIT to a backward CS but were unaltered in conditioned approach. Conclusions Amphetamine sensitization prevents outcome-selective responding during PIT, which is dissociable from amphetamine’s effects on conditioned approach. These data suggest fundamental alterations in how stimuli motivate action in addiction. PMID:22562522

  14. Analysis of Idaho fire service education

    NASA Astrophysics Data System (ADS)

    Roberts, Walter O.

    1999-01-01

    Becoming a career fire fighter in the state of Idaho requires specialized knowledge and training. Fire science education at Idaho colleges and universities is available only to people who are affiliated with a fire department. Law enforcement curriculum, on the other hand, is available to any interested persons. A student in law enforcement can attend the Police Officers Standards and Training (POST) academy or participate in classes in one of Idaho's institutions for higher education. There are no fire academies in Idaho. Applicants wanting to become professional fire fighters in Idaho are required to compete with applicants from other states; many of whom have had prior fire education and training. Resident Idaho fire fighter applicants are at a disadvantage when applying for Idaho fire fighting positions. Because of this apparent need, I surveyed the Idaho fire chiefs, using a research instrument I developed in a graduate field research class. I wrote the research instrument to determine the educational needs of the Idaho fire service. The College of Southern Idaho (CSI) and the Idaho Fire Chiefs Association (IFCA) were the recipients of this survey. This report, Analysis of Idaho Fire Service Education, describes that research process from beginning to end.

  15. Effects of Barbell Deadlift Training on Submaximal Motor Unit Firing Rates for the Vastus Lateralis and Rectus Femoris

    PubMed Central

    Stock, Matt S.; Thompson, Brennan J.

    2014-01-01

    Previous investigations that have studied motor unit firing rates following strength training have been limited to small muscles, isometric training, or interventions involving exercise machines. We examined the effects of ten weeks of supervised barbell deadlift training on motor unit firing rates for the vastus lateralis and rectus femoris during a 50% maximum voluntary contraction (MVC) assessment. Twenty-four previously untrained men (mean age  = 24 years) were randomly assigned to training (n = 15) or control (n = 9) groups. Before and following the intervention, the subjects performed isometric testing of the right knee extensors while bipolar surface electromyographic signals were detected from the two muscles. The signals were decomposed into their constituent motor unit action potential trains, and motor units that demonstrated accuracy levels less than 92.0% were not considered for analysis. One thousand eight hundred ninety-two and 2,013 motor units were examined for the vastus lateralis and rectus femoris, respectively. Regression analyses were used to determine the linear slope coefficients (pulses per second [pps]/% MVC) and y-intercepts (pps) of the mean firing rate and firing rate at recruitment versus recruitment threshold relationships. Deadlift training significantly improved knee extensor MVC force (Cohen's d = .70), but did not influence force steadiness. Training had no influence on the slopes and y-intercepts for the mean firing rate and firing rate at recruitment versus recruitment threshold relationships. In agreement with previous cross-sectional comparisons and randomized control trials, our findings do not support the notion that strength training affects the submaximal control of motor units. PMID:25531294

  16. Firefighters from Mayport Naval Station train at CCAFS

    NASA Technical Reports Server (NTRS)

    2000-01-01

    Firefighters in full gear douse a fire on a simulated aircraft. The firefighters, who are with Fire and Emergency Services at the Naval Station Mayport, Fla., are taking part in fire training exercises at Cape Canaveral Air Force Station Pad 30.

  17. 78 FR 65678 - Assistance to Firefighters Grant Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-01

    ... (EMS) organizations, and state fire training academies for the purpose of enhancing the abilities of... medical services (EMS) organizations, and State Fire Training Academies (SFTAs) to enhance their ability.... Emergency Medical Services Providers: Fire departments and nonaffiliated EMS organizations; not less than 3...

  18. Firefighters from Mayport Naval Station train at CCAFS

    NASA Technical Reports Server (NTRS)

    2000-01-01

    A Mobile Aircraft Fire Trainer vehicle from Naval Station Mayport, Fla., stands by during fire training exercises at Cape Canaveral Air Force Station Pad 30. In the background is the simulated aircraft that was set on fire for the exercise. Firefighters with the Fire and Emergency Services at the Naval Station (in the background) gather around the site of the extinguished flames.

  19. 75 FR 44720 - Safety Zone; Live-Fire Gun Exercise, M/V Del Monte, James River, VA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-29

    ...-AA00 Safety Zone; Live-Fire Gun Exercise, M/V Del Monte, James River, VA AGENCY: Coast Guard, DHS... mariners from the hazards associated with live fire and explosive training events. DATES: This rule is... Hampton Roads was notified that the U.S. Navy will conduct a live fire and explosive training event...

  20. Spin Pit Application of Image Derotated Holographic Interferometry.

    DTIC Science & Technology

    1980-09-01

    temperatures resulting from induction heating of the test structuore through the interaction of the electromagnets and the magnetic ring. Subsequent...reference beam, and a Tektronix Model 7633 storage oscilloscope. When the laser is fired, a trigger signal from the laser power supply initiates the...rapid induction heating of the test structure due to the interaction of the electromagnets and the magnetic ring was evi(lent with the switch from dc to

  1. Improved Web 2.0 Strategy for FEMA to Enable Collaboration and a Shared Situational Awareness Across the Whole of Community

    DTIC Science & Technology

    2012-03-01

    Special thanks to Tamekia and Mia who dealt with all the sleepless nights, travel, mood swings and stress that goes with the program. I love you to...the actor, and the Mahddi; I will miss the fire pit, getting kicked out of snacko’s room, golfing with my fam, Gigs’mobile (he has the best cars

  2. Mental arithmetic leads to multiple discrete changes from baseline in the firing patterns of human thalamic neurons.

    PubMed

    Kim, J H; Ohara, S; Lenz, F A

    2009-04-01

    Primate thalamic action potential bursts associated with low-threshold spikes (LTS) occur during waking sensory and motor activity. We now test the hypothesis that different firing and LTS burst characteristics occur during quiet wakefulness (spontaneous condition) versus mental arithmetic (counting condition). This hypothesis was tested by thalamic recordings during the surgical treatment of tremor. Across all neurons and epochs, preburst interspike intervals (ISIs) were bimodal at median values, consistent with the duration of type A and type B gamma-aminobutyric acid inhibitory postsynaptic potentials. Neuronal spike trains (117 neurons) were categorized by joint ISI distributions into those firing as LTS bursts (G, grouped), firing as single spikes (NG, nongrouped), or firing as single spikes with sporadic LTS bursting (I, intermediate). During the spontaneous condition (46 neurons) only I spike trains changed category. Overall, burst rates (BRs) were lower and firing rates (FRs) were higher during the counting versus the spontaneous condition. Spike trains in the G category sometimes changed to I and NG categories at the transition from the spontaneous to the counting condition, whereas those in the I category often changed to NG. Among spike trains that did not change category by condition, G spike trains had lower BRs during counting, whereas NG spike trains had higher FRs. BRs were significantly greater than zero for G and I categories during wakefulness (both conditions). The changes between the spontaneous and counting conditions are most pronounced for the I category, which may be a transitional firing pattern between the bursting (G) and relay modes of thalamic firing (NG).

  3. Responding to Terrorist Incidents in Your Community: Flammable-Liquid Fire Fighting Techniques for Municipal and Rural Firefighters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denise Baclawski

    2010-03-08

    The University of Nevada, Reno Fire Science Academy (FSA) applied for grant funding to develop and deliver programs for municipal, rural, and volunteer firefighters. The FSA specializes in preparing responders for a variety of emergency events, including flammable liquid fires resulting from accidents, intentional acts, or natural disasters. Live fire training on full scale burnable props is the hallmark of FSA training, allowing responders to practice critical skills in a realistic, yet safe environment. Unfortunately, flammable liquid live fire training is often not accessible to municipal, rural, or volunteer firefighters due to limited department training budgets, even though most departmentmore » personnel will be exposed to flammable liquid fire incidents during the course of their careers. In response to this training need, the FSA developed a course during the first year of the grant (Year One), Responding to Terrorist Incidents in Your Community: Flammable-Liquid Fire Fighting Techniques for Municipal and Rural Firefighters. During the three years of the grant, a total of 2,029 emergency responders received this training. In Year Three, two new courses, a train-the-trainer for Responding to Terrorist Incidents in Your Community and Management of Large-Scale Disasters for Public Officials were developed and pilot tested during the Real-World Disaster Management Conference held at the FSA in June of 2007. Two research projects were conducted during Years Two and Three. The first, conducted over a two year period, evaluated student surveys regarding the value of the flammable liquids training received. The second was a needs assessment conducted for rural Nevada. Both projects provided important feedback and a basis for curricula development and improvements.« less

  4. The effects of acute stress on Pavlovian-instrumental transfer in rats.

    PubMed

    Pielock, Steffi M; Braun, Stephanie; Hauber, Wolfgang

    2013-03-01

    Pavlovian stimuli invigorate ongoing instrumental action, a phenomenon termed the Pavlovian-instrumental transfer (PIT) effect. Acute stressors can markedly enhance the release of corticotropin-releasing factor (CRF), and CRF injection into the nucleus accumbens increases the PIT effect. However, it is unknown whether acute stressors by themselves would amplify the PIT effect. Here, we examined the effects of acute stressors on PIT. Rats first received Pavlovian and instrumental training, and then the impact of the Pavlovian stimuli on instrumental responding was analyzed in the subsequent PIT test. Acute stressors were applied prior to the PIT test. Because the effects of acute stressors critically depend on stressor type and time of day, we used two acute stressors that involved one or several distinct stressors (denoted here as "single" vs. "multiple" stressors) applied either in the light or the dark period of the light:dark cycle. The results revealed that single and multiple stressors applied in the light period did not alter the PIT effect--that is, the ability of an appetitive Pavlovian stimulus to enhance leverpressing--or the basal leverpress rate. When applied in the dark period, single and multiple stressors also did not alter the PIT effect, but they did markedly reduce the basal leverpress rate. Diazepam pretreatment did not counteract the declines in basal instrumental responding in the PIT test that were induced by either a single or multiple stressors. Our findings suggest that acute stressors were unable to amplify the incentive salience of reward-predictive Pavlovian stimuli to activate instrumental responding, but, depending on the time of day of stressor exposure, they did reduce basal instrumental responding.

  5. THE EFFECTS OF COMPUTER-BASED FIRE SAFETY TRAINING ON THE KNOWLEDGE, ATTITUDES, AND PRACTICES OF CAREGIVERS

    PubMed Central

    Harrington, Susan S.; Walker, Bonnie L.

    2010-01-01

    Background Older adults in small residential board and care facilities are at a particularly high risk of fire death and injury because of their characteristics and environment. Methods The authors investigated computer-based instruction as a way to teach fire emergency planning to owners, operators, and staff of small residential board and care facilities. Participants (N = 59) were randomly assigned to a treatment or control group. Results Study participants who completed the training significantly improved their scores from pre- to posttest when compared to a control group. Participants indicated on the course evaluation that the computers were easy to use for training (97%) and that they would like to use computers for future training courses (97%). Conclusions This study demonstrates the potential for using interactive computer-based training as a viable alternative to instructor-led training to meet the fire safety training needs of owners, operators, and staff of small board and care facilities for the elderly. PMID:19263929

  6. 49 CFR 193.2717 - Training: fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... their immediate supervisors, must be trained according to a written plan of initial instruction... under § 193.2801. (b) A written plan of continuing instruction, including plant fire drills, must be... personnel hands-on experience in carrying out their duties under the fire emergency procedures required by...

  7. Occupational exposure to polybrominated diphenyl ethers (PBDEs) and other flame retardant foam additives at gymnastics studios: Before, during and after the replacement of pit foam with PBDE-free foams.

    PubMed

    Ceballos, Diana M; Broadwater, Kendra; Page, Elena; Croteau, Gerry; La Guardia, Mark J

    2018-07-01

    Coaches spend long hours training gymnasts of all ages aided by polyurethane foam used in loose blocks, mats, and other padded equipment. Polyurethane foam can contain flame retardant additives such as polybrominated diphenyl ethers (PBDEs), to delay the spread of fires. However, flame retardants have been associated with endocrine disruption and carcinogenicity. The National Institute for Occupational Safety and Health (NIOSH) evaluated employee exposure to flame retardants in four gymnastics studios utilized by recreational and competitive gymnasts. We evaluated flame retardant exposure at the gymnastics studios before, during, and after the replacement of foam blocks used in safety pits with foam blocks certified not to contain several flame retardants, including PBDEs. We collected hand wipes on coaches to measure levels of flame retardants on skin before and after their work shift. We measured flame retardant levels in the dust on window glass in the gymnastics areas and office areas, and in the old and new foam blocks used throughout the gymnastics studios. We found statistically higher levels of 9 out of 13 flame retardants on employees' hands after work than before, and this difference was reduced after the foam replacement. Windows in the gymnastics areas had higher levels of 3 of the 13 flame retardants than windows outside the gymnastics areas, suggesting that dust and vapor containing flame retardants became airborne. Mats and other padded equipment contained levels of bromine consistent with the amount of brominated flame retardants in foam samples analyzed in the laboratory. New blocks did not contain PBDEs, but did contain the flame retardants 2-ethylhexyl 2,3,4,5-tetrabromobenzoate and 2-ethylhexyl 2,3,4,5-tetrabromophthalate. We conclude that replacing the pit foam blocks eliminated a source of PBDEs, but not 2-ethylhexyl 2,3,4,5-tetrabromobenzoate and 2-ethylhexyl 2,3,4,5-tetrabromophthalate. We recommend ways to further minimize employee exposure to flame retardants at work and acknowledge the challenges consumers have identifying chemical contents of new products. Published by Elsevier Ltd.

  8. Distribution of petroleum hydrocarbons and toluene biodegradation, Knox Street fire pits, Fort Bragg, North Carolina

    USGS Publications Warehouse

    Harden, S.L.; Landmeyer, J.E.

    1996-01-01

    An investigation was conducted at the Knox Street fire pits, Fort Bragg, North Carolina, to monitor the distribution of toluene, ethylbenzene, and xylene (TEX) in soil vapor, ground water, and ground-water/vapor to evaluate if total concentrations of TEX at the site are decreasing with time, and to quantify biodegradation rates of toluene in the unsaturated and saturated zones. Soil-vapor and ground-water samples were collected around the fire pits and ground-water/vapor samples were collected along the ground-water discharge zone, Beaver Creek, on a monthly basis from June 1994 through June 1995. Concentrations of TEX compounds in these samples were determined with a field gas chro- matograph. Laboratory experiments were performed on aquifer sediment samples to measure rates of toluene biodegradation by in situ micro- organisms. Based on field gas chromatographic analytical results, contamination levels of TEX compounds in both soil vapor and ground water appear to decrease downgradient of the fire-pit source area. During the 1-year study period, the observed temporal and spatial trends in soil vapor TEX concentrations appear to reflect differences in the distribution of TEX among solid, aqueous, and gaseous phases within fuel-contaminated soils in the unsaturated zone. Soil temperature and soil moisture are two important factors which influence the distribution of TEX com- pounds among the different phases. Because of the short period of data collection, it was not possible to distinguish between seasonal fluc- tuations in soil vapor TEX concentrations and an overall net decrease in TEX concentrations at the study site. No seasonal trend was observed in total TEX concentrations for ground- water samples collected at the study site. Although the analytical results could not be used to determine if ground-water TEX concen- trations decreased during the study at a specific location, the data were used to examine rate constants of toluene biodegradation. Based on ground-water toluene concentration data, a maximum rate constant for anaerobic biodegradation of toluene in the saturated zone was estimated to be as low as 0.002 d-1 or as high as 0.026 d-1. Based on analyses of ground-water/vapor samples, toluene was the prin- cipal TEX compound identified in ground water discharging to Beaver Creek. Observed decreases in ground-water/vapor toluene concentrations during the study period may reflect a decrease in source inputs, an increase in dilution caused by higher ground-water flow, and(or) removal by biological or other physical processes. Rate constants of toluene anaerobic biodegradation determined by laboratory measurements illustrate a typical acclimation response of micro-organisms to hydrocarbon contamination in sediments collected from the site. Toluene biodegradation rate constants derived from laboratory microcosm studies ranged from 0.001 to 0.027 d-1, which is similar to the range of 0.002 to 0.026 d-1 for toluene biodegradation rate constants derived from ground-water analytical data. The close agreement of toluene biodegradation rate constants reported using both approaches offer strong evidence that toluene can be degraded at environmentally significant rates at the study site.

  9. Social validation and training of emergency fire safety skills for potential injury prevention and life saving.

    PubMed Central

    Jones, R T; Kazdin, A E; Haney, J I

    1981-01-01

    A multifaceted behavioral program designed to teach emergency fire escape procedures to children was evaluated in a multiple-baseline design. Five children were trained to respond correctly to nine home emergency fire situations under simulated conditions. The situations and responses focused upon in training were identified by a social validation procedure involving consultation with several safety agencies, including the direct input of firefighters. Training, carried out in simulated bedrooms at school, resulted in significant improvements in both overt behavior and self-report of fire safety skills. The gains were maintained at a post-check assessment 2 weeks after training had been terminated. The results are discussed in relation both to the importance of social validation of targets and outcomes and the implications for further research in assessing and developing emergency response skills. PMID:7298537

  10. Emergency Management Computer-Aided Trainer (EMCAT)

    NASA Technical Reports Server (NTRS)

    Rodriguez, R. C.; Johnson, R. P.

    1986-01-01

    The Emergency Management Computer-Aided Trainer (EMCAT) developed by Essex Corporation or NASA and the Federal Emergency Management Administration's (FEMA) National Fire Academy (NFA) is described. It is a computer based training system for fire fighting personnel. A prototype EMCAT system was developed by NASA first using video tape images and then video disk images when the technology became available. The EMCAT system is meant to fill the training needs of the fire fighting community with affordable state-of-the-art technologies. An automated real time simulation of the fire situation was needed to replace the outdated manual training methods currently being used. In order to be successful, this simulator had to provide realism, be user friendly, be affordable, and support multiple scenarios. The EMCAT system meets these requirements and therefore represents an innovative training tool, not only for the fire fighting community, but also for the needs of other disciplines.

  11. Fire Safety of Passenger Trains: A Review of U.S. and Foreign Approaches

    DOT National Transportation Integrated Search

    1993-12-01

    could develop into potentially life-threatening events. Fire safety is an area of particular interest for both : conventional intercity and commuter trains, as well as new alternative high-speed train technologies. These : technologies include steel-...

  12. Firefighters from Mayport Naval Station train at CCAFS

    NASA Technical Reports Server (NTRS)

    2000-01-01

    A training officer controls elements of a fire training exercise at Cape Canaveral Air Force Station Pad 30 for firefighters with Fire and Emergency Services at the Naval Station Mayport, Fla. The firefighters tackled flames from a burning simulated aircraft.

  13. Education for Public Service.

    ERIC Educational Resources Information Center

    New England Board of Higher Education, Wellesley, MA.

    Issues in the improvement of training for fire fighters and officer personnel were taken up in ten symposium papers. Session 1 covered legal and other constraints that affect what a fire fighter should know; and current practices in volunteer, rural, and municipal fire fighter training in the United States. Papers from the other sessions dealt…

  14. Millwright Apprenticeship. Related Training Modules. 1.1-1.8 Safety.

    ERIC Educational Resources Information Center

    Lane Community Coll., Eugene, OR.

    This packet, part of the instructional materials for the Oregon apprenticeship program for millwright training, contains eight modules covering safety. The modules provide information on the following topics: general safety, hand tool safety, power tool safety, fire safety, hygiene, safety and electricity, types of fire and fire prevention, and…

  15. U.S. Coast Guard cutter personnel on Sweetbriar train their fire ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    U.S. Coast Guard cutter personnel on Sweetbriar train their fire hoses on a burning pleasure boat in an Alaskan harbor. A U.S. Coast Guard rigid-hull inflatable helps with the fire-fighting effort - U.S. Coast Guard Cutter SWEETBRIER, Cordova, Valdez-Cordova Census Area, AK

  16. Gear Tooth Wear Detection Algorithm

    NASA Technical Reports Server (NTRS)

    Delgado, Irebert R.

    2015-01-01

    Vibration-based condition indicators continue to be developed for Health Usage Monitoring of rotorcraft gearboxes. Testing performed at NASA Glenn Research Center have shown correlations between specific condition indicators and specific types of gear wear. To speed up the detection and analysis of gear teeth, an image detection program based on the Viola-Jones algorithm was trained to automatically detect spiral bevel gear wear pitting. The detector was tested using a training set of gear wear pictures and a blind set of gear wear pictures. The detector accuracy for the training set was 75 percent while the accuracy for the blind set was 15 percent. Further improvements on the accuracy of the detector are required but preliminary results have shown its ability to automatically detect gear tooth wear. The trained detector would be used to quickly evaluate a set of gear or pinion pictures for pits, spalls, or abrasive wear. The results could then be used to correlate with vibration or oil debris data. In general, the program could be retrained to detect features of interest from pictures of a component taken over a period of time.

  17. Fire in the Shop!

    ERIC Educational Resources Information Center

    Campbell, Clifton P.; Buchanan, Joseph P.

    1977-01-01

    Fire emergency preparedness measures to take to prevent school fires and to protect against injury and minimize damage when fire does occur are presented. Includes fire safety practices, extinguishers for different classes of fires and their use, and the need for fire safety training in schools. (MF)

  18. Earth Observation taken during the Expedition 37 mission

    NASA Image and Video Library

    2013-10-30

    ISS037-E-022990 (30 Oct. 2013) --- This detailed image, photographed by an Expedition 37 crew member on the International Space Station, features the former US Borax mine located to the northwest of Boron, California. The mine, currently owned by the Rio Tinto Group, is the largest open-pit mine in California (covering approximately 54 square kilometers) and is among the largest borate mines in the world. Borates, chemical compounds that include the element boron (B), are important both as providers of an essential plant micronutrient, for metallurgical applications, and as components of specialized types of glass, anticorrosive coatings, fire retardants, and detergents (among other uses). Borate minerals such as borax, kernite, and ulexite are found in deposits at the Rio Tinto borax mine. The geologic setting is a structural, nonmarine basin ? a permanent shallow lake ? fed by thermal springs rich in sodium and boron that existed approximately 16 million years ago, according to scientists. The first mining claim in the area was filed in 1913, following discovery of boron-bearing nodules during well drilling. Much of the mine workings were underground until 1957, when US Borax changed to open-pit mining. The open pit is clearly visible at center; concentric benches along the pit wall are accentuated by shadows and mark successive levels of material extraction. Mine tailings are visible as stacked terraces along the northern boundary of the mine. Ore processing facilities occupy a relatively small percentage of the mine area, and are located directly to the west of the open pit. The Rio Tinto mine is one of the Earth?s richest borate deposits; together with mines in Argentina, they produce almost 40 percent of the world?s supply of industrial borate minerals.

  19. Effects of Climate Change and Urban Development on Army Training Capabilities: Firing Ranges and Maneuver Areas

    DTIC Science & Technology

    2016-08-01

    ER D C TR -1 6- 1 Integrated Climate Assessment for Army Enterprise Planning Effects of Climate Change and Urban Development on Army...ERDC TR-16-1 January 2016 Effects of Climate Change and Urban Development on Army Training Capabilities Firing Ranges and Maneuver Areas Michelle E... changes associated with climate and urban development might affect the ability of Army installa- tions to continue to conduct training on firing ranges

  20. Dynamic interactions of the asialoglycoprotein receptor subunits with coated pits. Enhanced interactions of H2 following association with H1.

    PubMed

    Katzir, Z; Nardi, N; Geffen, I; Fuhrer, C; Henis, Y I

    1994-08-26

    Lateral mobility studies comparing native and mutated membrane proteins, combined with treatments that alter clathrin lattice structure, can measure membrane protein-coated pit interactions in intact cells (Fire, E., Zwart, D., Roth, M. G., and Henis, Y. I. (1991) J. Cell Biol. 115, 1585-1594). We applied this approach to study the interactions of the H1 and H2 human asialoglycoprotein receptor subunits with coated pits. The lateral mobilities of singly expressed and coexpressed H1 and H2B (the H2 species that reaches the cell surface) were measured by fluorescence photobleaching recovery. They were compared with mutant proteins, H1(5A) (Tyr-5 replaced by Ala) and H2(5A) (Phe-5 replaced by Ala). While the mobile fractions of H1, H2B, and their mutants were similar, the lateral diffusion rate (measured by D, the lateral diffusion coefficient) was significantly slower for H1, whether expressed alone or with H2B. Coexpression with H1 reduced D of H2B to that of H1. Disruption of the clathrin lattices by hypertonic medium elevated D of H1, H1(5A), H2B, and H2(5A) to the same final level, without affecting their mobile fractions. Cytosol acidification, which retains altered clathrin lattices attached to the membrane and prevents coated vesicle formation, immobilized part of the H1 molecules, reflecting stable entrapment in "frozen" coated pits. H1(5A), H2B, and H2(5A) were not affected; however, coexpression of H2B with H1 conferred the sensitivity to cytosol acidification on H2B. Our results suggest that H1 lateral mobility is inhibited by dynamic interactions with coated pits in which Tyr-5 is involved. H2B resembles H1(5A) rather than H1, and its interactions with coated pits are weaker; efficient interaction of H2B with coated pits depends on complex formation with H1.

  1. 46 CFR 166.15 - Training for maintenance of discipline; ship sanitation; fire and lifeboat drills.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...; fire and lifeboat drills. 166.15 Section 166.15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... maintenance of discipline; ship sanitation; fire and lifeboat drills. All students shall be trained to obey... the fundamentals of ship sanitation as prescribed by law and regulations, and shall be given intensive...

  2. 46 CFR 166.15 - Training for maintenance of discipline; ship sanitation; fire and lifeboat drills.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...; fire and lifeboat drills. 166.15 Section 166.15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... maintenance of discipline; ship sanitation; fire and lifeboat drills. All students shall be trained to obey... the fundamentals of ship sanitation as prescribed by law and regulations, and shall be given intensive...

  3. 46 CFR 166.15 - Training for maintenance of discipline; ship sanitation; fire and lifeboat drills.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...; fire and lifeboat drills. 166.15 Section 166.15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... maintenance of discipline; ship sanitation; fire and lifeboat drills. All students shall be trained to obey... the fundamentals of ship sanitation as prescribed by law and regulations, and shall be given intensive...

  4. 46 CFR 166.15 - Training for maintenance of discipline; ship sanitation; fire and lifeboat drills.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...; fire and lifeboat drills. 166.15 Section 166.15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... maintenance of discipline; ship sanitation; fire and lifeboat drills. All students shall be trained to obey... the fundamentals of ship sanitation as prescribed by law and regulations, and shall be given intensive...

  5. 46 CFR 166.15 - Training for maintenance of discipline; ship sanitation; fire and lifeboat drills.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...; fire and lifeboat drills. 166.15 Section 166.15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... maintenance of discipline; ship sanitation; fire and lifeboat drills. All students shall be trained to obey... the fundamentals of ship sanitation as prescribed by law and regulations, and shall be given intensive...

  6. Control of voluntary and optogenetically perturbed locomotion by spike rate and timing of neurons of the mouse cerebellar nuclei

    PubMed Central

    Sarnaik, Rashmi

    2018-01-01

    Neurons of the cerebellar nuclei (CbN), which generate cerebellar output, are inhibited by Purkinje cells. With extracellular recordings during voluntary locomotion in head-fixed mice, we tested how the rate and coherence of inhibition influence CbN cell firing and well-practiced movements. Firing rates of Purkinje and CbN cells were modulated systematically through the stride cycle (~200–300 ms). Optogenetically stimulating ChR2-expressing Purkinje cells with light steps or trains evoked either asynchronous or synchronous inhibition of CbN cells. Steps slowed CbN firing. Trains suppressed CbN cell firing less effectively, but consistently altered millisecond-scale spike timing. Steps or trains that perturbed stride-related modulation of CbN cell firing rates correlated well with irregularities of movement, suggesting that ongoing locomotion is sensitive to alterations in modulated CbN cell firing. Unperturbed locomotion continued more often during trains than steps, however, suggesting that stride-related modulation of CbN spiking is less readily disrupted by synchronous than asynchronous inhibition. PMID:29659351

  7. The development of the residential Fire H.E.L.P. tool kit: a resource to protect homebound older adults.

    PubMed

    Diekman, Shane; Huitric, Michele; Netterville, Linda

    2010-01-01

    This article describes the development of the Fire H.E.L.P. tool kit for training selected Meals On Wheels (MOW) staff in Texas to implement a fire safety program for homebound older adults. We used a formative evaluation approach during the tool kit's development, testing, and initial implementation stages. The tool kit includes instructional curricula on how to implement Fire H.E.L.P., a home assessment tool to determine a residence's smoke alarm needs, and fire safety educational materials. During the tool kit's pilot test, MOW participants showed enhanced fire safety knowledge and high levels of confidence about applying their newfound training skills. After the pilot test, MOW staff used the tool kit to conduct local training sessions, provide fire safety education, and install smoke alarms in the homes of older adults. We believe the approach used to develop this tool kit can be applied to education efforts for other, related healthy home topics.

  8. Fire/security staff member instructs STS-29 crew on fire extinguisher usage

    NASA Image and Video Library

    1988-12-06

    S88-54948 (6 Dec 1988) --- The STS-29 crewmembers are trained in procedures to follow in the event of a fire with their spacecraft. Here, the crew is briefed on correct handling of the fire extinguisher by Robert Fife (far left) of NASA's fire and security staff. Pictured, left to right, are Astronauts John E. Blaha, pilot; Michael L. Coats, mission commander; Robert C. Springer, James F. Buchli and James P. Bagian, mission specialists. The training exercise took place on the northern end of the 1625-acre JSC facility.

  9. Requirements and Regulations for Open Burning and Fire Training

    EPA Pesticide Factsheets

    Intentional burning of facilities is considered demolition under federal asbestos regulations, even if no asbestos is present. Learn about regulations and requirements for open burning and fire training.

  10. Credit PSR. This view depicts the southwest and southeast facades ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit PSR. This view depicts the southwest and southeast facades as seen when looking west southwest (260°). The building consists of a small lean-to control room and a two-story space containing a large casting pit. The pit, which can be seen through the open doors, was never used due to changes in JPL's mission. This steel frame structure is clad in "Transite" board (a fire resistant pressed asbestos composite material) and interior lighting consists of individual explosion proof lamps mounted around the walls. The building was rated for 10,000 pounds (4,545 Kg) of class 2 materials and four personnel. It was licensed 5 June 1989 for ammonium perchlorate (NH4C10,), ammonium nitrate (NH4NO3), and sodium nitrate (NaNO3) - Jet Propulsion Laboratory Edwards Facility, Casting & Curing Building, Edwards Air Force Base, Boron, Kern County, CA

  11. A Comprehensive Review of Firefighter Post-Secondary Training and Education in Florida. Program Review Report.

    ERIC Educational Resources Information Center

    Florida State Dept. of Education, Tallahassee. Div. of Vocational, Adult, and Community Education.

    Florida's community college and school district postsecondary adult vocational programs in fire fighter training and fire science technology were subjected to a statewide program review. Efforts were made to reach Florida's entire community of career and volunteer fire fighters. Data were collected in the following ways: site interviews with…

  12. Intelligent Conduct of Fire Trainer: Intelligent Technology Applied to Simulator-Based Training.

    ERIC Educational Resources Information Center

    Newman, Denis; And Others

    1989-01-01

    Describes an intelligent tutoring system (ITS) that demonstrates how intelligent feedback can enhance conventional simulation-based training. An explanation is given of the Intelligent Conduct of Fire Trainer (INCOFT), which was designed to provide training exercises for soldiers operating the PATRIOT missile system, and its implications for…

  13. Wildfires in Chile: A review

    NASA Astrophysics Data System (ADS)

    Úbeda, Xavier; Sarricolea, Pablo

    2016-11-01

    This paper reviews the literature examining the wildfire phenomenon in Chile. Since ancient times, Chile's wildfires have shaped the country's landscape, but today, as in many other parts of the world, the fire regime - pattern, frequency and intensity - has grown at an alarming rate. In 2014, > 8000 fires were responsible for burning c. 130,000 ha, making it the worst year in Chile's recent history. The reasons for this increase appear to be the increment in the area planted with flammable species; the rejection of these landscape modifications on the part of local communities that target these plantations in arson attacks; and, the adoption of intensive forest management practices resulting in the accumulation of a high fuel load. These trends have left many native species in a precarious situation and forest plantation companies under considerable financial pressure. An additional problem is posed by fires at the wildland urban interface (WUI), threatening those inhabitants that live in Chile's most heavily populated cities. The prevalence of natural fires in Chile; the relationship between certain plant species and fire in terms of seed germination strategies and plant adaptation; the relationship between fire and invasive species; and, the need for fire prevention systems and territorial plans that include fire risk assessments are some of the key aspects discussed in this article. Several of the questions raised will require further research, including just how fire-dependent the ecosystems in Chile are, how the forest at the WUI can be better managed to prevent human and material damage, and how best to address the social controversy that pits the Mapuche population against the timber companies.

  14. 46 CFR 12.602 - Basic training.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) Swimming while wearing a lifejacket. (v) Keeping afloat without a lifejacket. (2) Fire prevention and... extinguishers. (ii) Extinguishing smaller fires. e.g., electrical fires, oil fires, and propane fires. (iii... firefighting agent in an accommodation room or simulated engine room with fire and heavy smoke. (vii...

  15. Fire Safety Training with Adults Who Are Profoundly Mentally Retarded.

    ERIC Educational Resources Information Center

    Rae, Rosamond; Roll, David

    1985-01-01

    An intensive fire safety training program for profoundly mentally retarded institutionalized persons resulted in a significant decrease in mean evacuation time and gradual substitution of verbal for physical prompts. (CL)

  16. Fire Rescue Exercise

    NASA Image and Video Library

    2014-03-06

    CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida prepare to participate in a training exercise at the Shuttle Landing Facility. A small fire is burning near a mock-up of a plane during the training exercise. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett

  17. Fire Rescue Exercise

    NASA Image and Video Library

    2014-03-06

    CAPE CANAVERAL, Fla. - During a training exercise, Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida use hoses to put out a fire burning on a mock-up of a small plane at the Shuttle Landing Facility. They are wearing protective gear for the training exercise. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett

  18. Fire Safety Training Handbook.

    ERIC Educational Resources Information Center

    Montgomery County Dept. of Fire and Rescue Services, Rockville, MD. Div. of Fire Prevention.

    Designed for a community fire education effort, particularly in which local volunteers present general information on fire safety to their fellow citizens, this workbook contains nine lessons. Included are an overview of the household fire problem; instruction in basic chemistry and physics of fire, flammable liquids, portable fire extinguishers,…

  19. Detection of Bursts and Pauses in Spike Trains

    PubMed Central

    Ko, D.; Wilson, C. J.; Lobb, C. J.; Paladini, C. A.

    2012-01-01

    Midbrain dopaminergic neurons in vivo exhibit a wide range of firing patterns. They normally fire constantly at a low rate, and speed up, firing a phasic burst when reward exceeds prediction, or pause when an expected reward does not occur. Therefore, the detection of bursts and pauses from spike train data is a critical problem when studying the role of phasic dopamine (DA) in reward related learning, and other DA dependent behaviors. However, few statistical methods have been developed that can identify bursts and pauses simultaneously. We propose a new statistical method, the Robust Gaussian Surprise (RGS) method, which performs an exhaustive search of bursts and pauses in spike trains simultaneously. We found that the RGS method is adaptable to various patterns of spike trains recorded in vivo, and is not influenced by baseline firing rate, making it applicable to all in vivo spike trains where baseline firing rates vary over time. We compare the performance of the RGS method to other methods of detecting bursts, such as the Poisson Surprise (PS), Rank Surprise (RS), and Template methods. Analysis of data using the RGS method reveals potential mechanisms underlying how bursts and pauses are controlled in DA neurons. PMID:22939922

  20. Firefighters from Mayport Naval Station train at CCAFS

    NASA Technical Reports Server (NTRS)

    2000-01-01

    During training exercises at Cape Canaveral Air Force Station Pad 30, firefighters with the Fire and Emergency Services at the Naval Station Mayport, Fla., turn their hoses toward the fire on the simulated aircraft.

  1. The Development of a Single Tank Tactical Exercise for Training M1 Tank Commanders

    DTIC Science & Technology

    1987-06-01

    Evaluate the Conduct of Training NL NL NS Fire an M250 Grenade Launcher S S NS Identify Adjoining Map Sheets S S NS Identify Terrain Features on a Map S S...the Commander’s Weapon Station Establish, Enter, and Leave a Radio Net Estimate Range Evaluate the Conduct of Training Fire an M250 Grenade Launcher...from the Commander’s Weapon S Station (CWS) Fire an M250 Smoke Grenade Launcher Set Headspace and Timing on a Caliber .50 M2 HB Machinegun Zero a

  2. Fire Weather Products for Public and Emergency Use: Extending Professional Resources to the Public

    NASA Astrophysics Data System (ADS)

    Rogers, M. A.; Schranz, S.; Kriederman, L.

    2012-12-01

    Large wildfires require significant resources to combat, including dedicated meteorological support to provide accurate and timely forecasts to assist incident commanders in making decisions for logistical and tactical firefighting operations. Smaller fires often require the same capabilities for understanding fire and the fire weather environment, but access to needed resources and tools is often limited due to technical, training, or education limitations. Providing fire weather information and training to incident commanders for smaller wildfires should prove to enhance firefighting capabilities and improve safety for both firefighters and for the public as well. One of the premier tools used to support fire weather forecasting for the largest wildfires is the FX-Net product, a thin-client version of the Advanced Weather Interactive Processing System used by NWS incident meteorologists (IMETs) deployed to large wildfires. We present results from an ongoing project to extend the sophisticated products available from FX-Net to more accessible and mobile software platforms, such as Google Earth. The project involves input from IMETs and fire commanders to identify the key parameters used in fighting wildfires, and involves a large training component for fire responders to utilize simplified products to improve understanding of fire weather in the context of firefighting operations.

  3. A Feasibility Study on the Establishment of a Fire Fighting Academy for the State of New Mexico.

    ERIC Educational Resources Information Center

    Sanchez, Alex A.

    The report on the desirability and feasibility of establishing the New Mexico State Fire Academy and firemen training program is presented in three parts: (1) the result of a survey of firemen training, (2) a proposal for a total system of firemen training, and (3) an analysis of the cost of implementing this program of training and education. The…

  4. Tools, courses, and learning pathways offered by the National Interagency Fuels, Fire, and Vegetation Technology Transfer

    Treesearch

    Eva K. Strand; Kathy H. Schon; Jeff Jones

    2010-01-01

    Technological advances in the area of fuel and wildland fire management have created a need for effective decision support tools and technology training. The National Interagency Fuels Committee and LANDFIRE have chartered a team to develop science-based learning tools for assessment of fire and fuels and to provide online training and technology transfer to help...

  5. Fire Rescue Exercise

    NASA Image and Video Library

    2014-03-06

    CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida review procedures after participating in a training exercise at the Shuttle Landing Facility. During the training simulation, firefighters used fire trucks and hoses to extinguish flames burning on and around a mock-up of a small plane. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett

  6. Occurrence and persistence of perfluorooctanesulfonate and other perfluorinated surfactants in groundwater at a fire-training area at Wurtsmith Air Force Base, Michigan, USA.

    PubMed

    Moody, Cheryl A; Hebert, Gretchen N; Strauss, Steven H; Field, Jennifer A

    2003-04-01

    Various formulations of fire-extinguishing materials, including aqueous film-forming foams (AFFFs), were used as part of fire-training exercises conducted at Wurtsmith Air Force Base (WAFB) in northeastern Michigan from the 1950s until the base was decommissioned in 1993. As a result of past fire-training exercises, AFFF-laden wastewater containing fuels, solvents, and other materials directly entered groundwater without prior treatment. Perfluorinated surfactants are key components in some AFFF formulations. In this study, groundwater was analyzed for perfluoroalkanesulfonates and perfluorocarboxylates. Perfluoroalkanesulfonates were directly detected using negative-ion electrospray ionization mass spectrometry. Derivatized perfluorocarboxylates were detected using electron impact gas chromatography-mass spectrometry. Groundwater from wells around fire-training area FTA-02 at WAFB contained four perfluorinated surfactants ranging in concentration from 3 to 120 microg L(-1): perfluorooctanesulfonate (PFOS); perfluorohexanesulfonate; perfluorooctanoate; and perfluorohexanoate. This is the first report demonstrating that PFOS, recently shown to be toxic to organisms ranging from zooplankton to primates, is still present in groundwater in measurable quantities five or more years after its last known use.

  7. The Fire-Alarm Game: Exit Training Using Negative and Positive Reinforcement under Varied Stimulus Conditions. Short Reports.

    ERIC Educational Resources Information Center

    Holburn, C. Steven; Dougher, Michael J.

    1985-01-01

    Techniques for training a severely retarded blind client to exit his living unit during a fire drill used a combination of negative and positive reinforcement. Following a shaping procedure, the client learned to leave his living unit from any internal point through generalization training and subsequent test probes. (Author/CL)

  8. Prospective Assessment of Chronic Multisymptom Illness Reporting Possibly Associated with Open-Air Burn Pit Smoke Exposure in Iraq

    DTIC Science & Technology

    2012-06-01

    clearly implicating any specific war exposure as a cause of postwar symptoms, which is noteworthy, given the large and contin- ued military presence in...dioxide, sulfur dioxide, and polycyclic aromatic hydrocarbons are being released in the smoke from the fires, and many are known carcinogens and may cause ...exposure by providing benefits to veterans who self-report this type of exposure and have a variety of health conditions.26 The Millennium Cohort Study was

  9. Providing Boiler Inspections at US Army Installations: How to Perform Internal/Operational, Efficiency, and Emissions Testing

    DTIC Science & Technology

    2013-08-01

    corrosion can be found on tubes , tubesheets, and in steam- drums, most often near the waterline in steam boilers . Oxygen pitting can also occur anywhere...components present in the feedwater onto wetted boiler surfaces including fire- tubes and water- tubes . Since scale is a good insulator, the thicker...steel surfaces of a steam boiler . However, heavier scale accumulates on the lower steel surfaces of the tubes , mud-drum, and boiler shell. SLUDGE

  10. 29 CFR 1910.156 - Fire brigades.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... training schools as the Maryland Fire and Rescue Institute; Iowa Fire Service Extension; West Virginia Fire... University, Lamar University, Reno Fire School, or the Delaware State Fire School.) (4) The employer shall... laboratory oven at a temperature of 500 °F (260 °C) for a period of five minutes. After cooling to ambient...

  11. Smoke detection

    DOEpatents

    Warmack, Robert J. Bruce; Wolf, Dennis A.; Frank, Steven Shane

    2016-09-06

    Various apparatus and methods for smoke detection are disclosed. In one embodiment, a method of training a classifier for a smoke detector comprises inputting sensor data from a plurality of tests into a processor. The sensor data is processed to generate derived signal data corresponding to the test data for respective tests. The derived signal data is assigned into categories comprising at least one fire group and at least one non-fire group. Linear discriminant analysis (LDA) training is performed by the processor. The derived signal data and the assigned categories for the derived signal data are inputs to the LDA training. The output of the LDA training is stored in a computer readable medium, such as in a smoke detector that uses LDA to determine, based on the training, whether present conditions indicate the existence of a fire.

  12. Smoke detection

    DOEpatents

    Warmack, Robert J. Bruce; Wolf, Dennis A.; Frank, Steven Shane

    2015-10-27

    Various apparatus and methods for smoke detection are disclosed. In one embodiment, a method of training a classifier for a smoke detector comprises inputting sensor data from a plurality of tests into a processor. The sensor data is processed to generate derived signal data corresponding to the test data for respective tests. The derived signal data is assigned into categories comprising at least one fire group and at least one non-fire group. Linear discriminant analysis (LDA) training is performed by the processor. The derived signal data and the assigned categories for the derived signal data are inputs to the LDA training. The output of the LDA training is stored in a computer readable medium, such as in a smoke detector that uses LDA to determine, based on the training, whether present conditions indicate the existence of a fire.

  13. 29 CFR 1926.155 - Definitions applicable to this subpart.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...

  14. 29 CFR 1926.155 - Definitions applicable to this subpart.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...

  15. 29 CFR 1926.155 - Definitions applicable to this subpart.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...

  16. 29 CFR 1926.155 - Definitions applicable to this subpart.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...

  17. 29 CFR 1926.155 - Definitions applicable to this subpart.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... part, fire resistance shall be determined by the Standard Methods of Fire Tests of Building... knowledgeable, trained, and skilled in the safe evacuation of employees during emergency situations and in assisting in fire fighting operations. (f) Fire resistance means so resistant to fire that, for specified...

  18. UNC Pembroke Laser Scanning Confocal Microscopy Facility

    DTIC Science & Technology

    2016-04-29

    cultures. INVASIVE FIRE ANTS Professor Lisa Kelly of UNC Pembroke has been trained on the new confocal system. Dr. Kelly’s research...interest in the trophic ecology of the invasive fire ant has begun to benefit from the wide field view and long working distances of a confocal imaging...of protein clearance pathways in living brain tissue cultures. INVASIVE FIRE ANTS Professor Lisa Kelly of UNC Pembroke has been trained on

  19. How EPA's Asbestos Regulations Apply to Residential Buildings Used for Fire Training

    EPA Pesticide Factsheets

    Memos and guidance from the Office of Air Quality Planning and Standards that clarify how the Asbestos National Emissions Standard for Hazardous Air Pollutants applies to residential buildings used for fire training, also known as acquired structures.

  20. KSC-00pp1442

    NASA Image and Video Library

    2000-09-14

    KENNEDY SPACE CENTER, FLA. -- A training officer controls elements of a fire training exercise at Cape Canaveral Air Force Station Pad 30 for firefighters with Fire and Emergency Services at the Naval Station Mayport, Fla. The firefighters tackled flames from a burning simulated aircraft.

  1. KSC00pp1442

    NASA Image and Video Library

    2000-09-14

    KENNEDY SPACE CENTER, FLA. -- A training officer controls elements of a fire training exercise at Cape Canaveral Air Force Station Pad 30 for firefighters with Fire and Emergency Services at the Naval Station Mayport, Fla. The firefighters tackled flames from a burning simulated aircraft.

  2. Teach Children Fire Will Burn.

    ERIC Educational Resources Information Center

    Children's Bureau (DHEW), Washington, DC.

    This handbook, addressed to parents and others responsible for the safety of children, presents information on fire hazards, prevention and protection. Emphasizing an early start to fire safety training, it outlines the basic facts of fire safety education, listing the most frequent causes of fire and suggesting the organization of a Family Fire…

  3. 14 CFR 121.417 - Crewmember emergency training.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... fire extinguishers, with emphasis on type of extinguisher to be used on different classes of fires; and... handling of emergency situations including— (i) Rapid decompression; (ii) Fire in flight or on the surface... crewmember combats an actual or simulated fire using at least one type of installed hand fire extinguisher or...

  4. 14 CFR 121.417 - Crewmember emergency training.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... fire extinguishers, with emphasis on type of extinguisher to be used on different classes of fires; and... handling of emergency situations including— (i) Rapid decompression; (ii) Fire in flight or on the surface... crewmember combats an actual or simulated fire using at least one type of installed hand fire extinguisher or...

  5. 14 CFR 121.417 - Crewmember emergency training.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... fire extinguishers, with emphasis on type of extinguisher to be used on different classes of fires; and... handling of emergency situations including— (i) Rapid decompression; (ii) Fire in flight or on the surface... crewmember combats an actual or simulated fire using at least one type of installed hand fire extinguisher or...

  6. Fire Safety. Managing School Facilities, Guide 6.

    ERIC Educational Resources Information Center

    Department for Education and Employment, London (England). Architects and Building Branch.

    This booklet discusses how United Kingdom schools can manage fire safety and minimize the risk of fire. The guide examines what legislation school buildings must comply with and covers the major risks. It also describes training and evacuation procedures and provides guidance on fire precautions, alarm systems, fire fighting equipment, and escape…

  7. Fire and worker health and safety: an introduction to the special issue.

    PubMed

    Campbell, Richard; Levenstein, Charles

    2015-02-01

    One century ago, the landmark fire at the Triangle Shirtwaist Factory in New York City claimed the lives of 146 garment workers and helped spur the adoption of fire safety measures and laws targeting dangerous working conditions. Since that time, continuing advances have been made to address the threat of fire-in workplace fire safety practices and regulations, in training and safety requirements for firefighters and first responders, and in hazard communication laws that enhance disaster planning and response. Recent high profile events, including the West, Texas fertilizer plant explosion, derailments of fuel cargo trains, and garment factory fires in Bangladesh, have brought renewed attention to fire as a workplace health and safety issue and to the unevenness of safety standards and regulatory enforcement, in the United States as well as internationally. In this article, we provide an overview of fire as a workplace health and safety hazard and an introduction to the essays included in this special issue of New Solutions on fire and work. © 2015 SAGE Publications.

  8. Effect of wearing personal protective clothing and self-contained breathing apparatus on heart rate, temperature and oxygen consumption during stepping exercise and live fire training exercises.

    PubMed

    Bruce-Low, S S; Cotterrell, D; Jones, G E

    2007-01-15

    Fire fighter breathing apparatus instructors (BAIs) must possess the ability to respond to both the extrinsic stress of a high temperature environment and the intrinsic stress from wearing personal protective equipment (PPE) and self-contained breathing apparatus (SCBA), repeatedly and regularly, whilst training recruits in live fire training exercises (LFTEs). There are few previous investigations on BAIs in hot environments such as LFTEs, since the main research focus has been on regular fire fighters undertaking exercises in temperate or fire conditions at a moderate to high exercise intensity. In this study, the intrinsic cardiovascular stress effects of wearing PPE + SCBA were first investigated using a step test whilst wearing gym kit (control), weighted gym kit (a rucksack weighted to the equivalent of PPE + SCBA) and full PPE + SCBA (weight plus the effects of protective clothing). The extrinsic effects of the very hot environment were investigated in BIAs in LFTEs compared to mock fire training exercises (MFTEs), where the fire was not ignited. There was an increase in heart rate due to the modest workload imposed on the BAIs through carrying out the MFTEs (25.0 (18.7)%) compared to resting. However, when exposed to fire during the LFTEs, heat storage appears to be significant as the heart rate increased by up to 39.8 (+/-20.1)% over that of the mock LFTEs at temperate conditions. Thus, being able to dissipate heat from the PPE is particularly important in reducing the cardiovascular responses for BAIs during LFTEs.

  9. Goal-oriented training affects decision-making processes in virtual and simulated fire and rescue environments.

    PubMed

    Cohen-Hatton, Sabrina R; Honey, R C

    2015-12-01

    Decisions made by operational commanders at emergency incidents have been characterized as involving a period of information gathering followed by courses of action that are often generated without explicit plan formulation. We examined the efficacy of goal-oriented training in engendering explicit planning that would enable better communication at emergency incidents. While standard training mirrored current operational guidance, goal-oriented training incorporated "decision controls" that highlighted the importance of evaluating goals, anticipated consequences, and risk/benefit analyses once a potential course of action has been identified. In Experiment 1, 3 scenarios (a house fire, road traffic collision, and skip fire) were presented in a virtual environment, and in Experiment 2 they were recreated on the fireground. In Experiment 3, the house fire was recreated as a "live burn," and incident commanders and their crews responded to this scenario as an emergency incident. In all experiments, groups given standard training showed the reported tendency to move directly from information gathering to action, whereas those given goal-oriented training were more likely to develop explicit plans and show anticipatory situational awareness. These results indicate that training can be readily modified to promote explicit plan formulation that could facilitate plan sharing between incident commanders and their teams. (c) 2015 APA, all rights reserved).

  10. Effects of military training activities on shrub-steppe raptors in southwestern Idaho, USA

    USGS Publications Warehouse

    Lehman, Robert N.; Steenhof, Karen; Kochert, Michael N.; Carpenter, L.B.

    1999-01-01

    Between 1991 and 1994, we assessed relative abundance, nesting success, and distribution of ferruginous hawks (Buteo regalis), northern harriers (Circus cyaneus), burrowing owls (Athene cunicularia), and short-eared owls (Asio flammeus) inside and outside a military training site in the Snake River Birds of Prey National Conservation Area, southwestern Idaho. The Orchard Training Area is used primarily for armored vehicle training and artillery firing by the Idaho Army National Guard. Relative abundance of nesting pairs inside and outside the training site was not significantly different from 1991 to 1993 but was significantly higher on the training site in 1994 (Pa??a??a??0.03). Nesting success varied among years but was not significantly different inside and outside the training site (Pa??>a??0.26). In 1994, short-eared owl and burrowing owl nests were significantly closer to firing ranges used early in the spring before owls laid eggs than were random points (Pa??

  11. Development of a hazard-based method for evaluating the fire safety of passenger trains

    DOT National Transportation Integrated Search

    1999-01-01

    The fire safety of U.S. passenger rail trains currently is addressed through small-scale flammability and smoke emission tests and performance criteria promulgated by the Federal Railroad Administration (FRA). The FRA approach relies heavily on test ...

  12. RCRA Facility Investigation/Remedial Investigation Report with Baseline Risk Assessment for the Fire Department Hose Training Facility (904-113G)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Palmer, E.

    1997-04-01

    This report documents the Resource Conservation and Recovery Act (RCRA) Facility Investigation/Remedial Investigation/Baseline Risk Assessment (RFI/RI/BRA) for the Fire Department Hose Training Facility (FDTF) (904-113G).

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warmack, Robert J. Bruce; Wolf, Dennis A.; Frank, Steven Shane

    Various apparatus and methods for smoke detection are disclosed. In one embodiment, a method of training a classifier for a smoke detector comprises inputting sensor data from a plurality of tests into a processor. The sensor data is processed to generate derived signal data corresponding to the test data for respective tests. The derived signal data is assigned into categories comprising at least one fire group and at least one non-fire group. Linear discriminant analysis (LDA) training is performed by the processor. The derived signal data and the assigned categories for the derived signal data are inputs to the LDAmore » training. The output of the LDA training is stored in a computer readable medium, such as in a smoke detector that uses LDA to determine, based on the training, whether present conditions indicate the existence of a fire.« less

  14. An organizational process for promoting home fire safety in two community settings.

    PubMed

    Lehna, Carlee; Twyman, Stephanie; Fahey, Erin; Coty, Mary-Beth; Williams, Joe; Scrivener, Drane; Wishnia, Gracie; Myers, John

    2017-02-01

    The purpose of this study was to describe the home fire safety quality improvement model designed to aid organizations in achieving institutional program goals. The home fire safety model was developed from community-based participatory research (CBPR) applying training-the-trainer methods and is illustrated by an institutional case study. The model is applicable to other types of organizations to improve home fire safety in vulnerable populations. Utilizing the education model leaves trained employees with guided experience to build upon, adapt, and modify the home fire safety intervention to more effectively serve their clientele, promote safety, and meet organizational objectives. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  15. Fire Rescue Exercise

    NASA Image and Video Library

    2014-03-06

    CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters use a fire truck to put out a fire burning close to a mock-up of a small plane and a truck. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett

  16. Improving NIR snow pit stratigraphy observations by introducing a controlled NIR light source

    NASA Astrophysics Data System (ADS)

    Dean, J.; Marshall, H.; Rutter, N.; Karlson, A.

    2013-12-01

    Near-infrared (NIR) photography in a prepared snow pit measures mm-/grain-scale variations in snow structure, as reflectivity is strongly dependent on microstructure and grain size at the NIR wavelengths. We explore using a controlled NIR light source to maximize signal to noise ratio and provide uniform incident, diffuse light on the snow pit wall. NIR light fired from the flash is diffused across and reflected by an umbrella onto the snow pit; the lens filter transmits NIR light onto the spectrum-modified sensor of the DSLR camera. Lenses are designed to refract visible light properly, not NIR light, so there must be a correction applied for the subsequent NIR bright spot. To avoid interpolation and debayering algorithms automatically performed by programs like Adobe's Photoshop on the images, the raw data are analyzed directly in MATLAB. NIR image data show a doubling of the amount of light collected in the same time for flash over ambient lighting. Transitions across layer boundaries in the flash-lit image are detailed by higher camera intensity values than ambient-lit images. Curves plotted using median intensity at each depth, normalized to the average profile intensity, show a separation between flash- and ambient-lit images in the upper 10-15 cm; the ambient-lit image curve asymptotically approaches the level of the flash-lit image curve below 15cm. We hypothesize that the difference is caused by additional ambient light penetrating the upper 10-15 cm of the snowpack from above and transmitting through the wall of the snow pit. This indicates that combining NIR ambient and flash photography could be a powerful technique for studying penetration depth of radiation as a function of microstructure and grain size. The NIR flash images do not increase the relative contrast at layer boundaries; however, the flash more than doubles the amount of recorded light and controls layer noise as well as layer boundary transition noise.

  17. Fire Streams. Fire Service Certification Series. Unit FSCS-FF-10-80.

    ERIC Educational Resources Information Center

    Pribyl, Paul F.

    This training unit on fire streams is part of a 17-unit course package written to aid instructors in the development, teaching, and evaluation of fire fighters in the Wisconsin Fire Service Certification Series. The purpose stated for the 8-hour unit is to provide the fire fighters with an understanding of the characteristics, use, and application…

  18. Fire Safety in Nursing Facilities: Participant's Coursebook.

    ERIC Educational Resources Information Center

    Walker (Bonnie) and Associates, Inc., Crofton, MD.

    Fewer people die in nursing facility fires than in fires occurring in other places where older people live. Fire remains, however, a significant threat in nursing facilities. This book is centered around six "modules" that present a fire safety training program for managers and staff in nursing homes. These modules present the following…

  19. Firefighter noise exposure during training activities and general equipment use.

    PubMed

    Root, Kyle S; Schwennker, Catherine; Autenrieth, Daniel; Sandfort, Delvin R; Lipsey, Tiffany; Brazile, William J

    2013-01-01

    Multiple noise measurements were taken on 6 types of fire station equipment and 15 types of emergency response vehicle-related equipment used by firefighters during routine and emergency operations at 10 fire stations. Five of the six types of fire station equipment, when measured at a distance of one meter and ear level, emitted noise equal to or greater than 85 dBA, including lawn maintenance equipment, snow blowers, compressors, and emergency alarms. Thirteen of 15 types of equipment located on the fire engines emitted noise levels equal to or greater than 85 dBA, including fans, saws, alarms, and extrication equipment. In addition, noise measurements were taken during fire engine operations, including the idling vehicle, vehicle sirens, and water pumps. Results indicated that idling fire-engine noise levels were below 85 dBA; however, during water pump and siren use, noise levels exceeded 85 dBA, in some instances, at different locations around the trucks where firefighters would be stationed during emergency operations. To determine if the duration and use of fire fighting equipment was sufficient to result in overexposures to noise during routine training activities, 93 firefighter personal noise dosimetry samples were taken during 10 firefighter training activities. Two training activities per sampling day were monitored during each sampling event, for a mean exposure time of 70 min per day. The noise dosimetry samples were grouped based on job description to compare noise exposures between the different categories of job tasks commonly associated with fire fighting. The three job categories were interior, exterior, and engineering. Mean personal dosimetry results indicated that the average noise exposure was 78 dBA during the training activities that lasted 70 min on average. There was no significant difference in noise exposure between each of the three job categories. Although firefighters routinely use equipment and emergency response vehicles that can produce hazardous levels of noise, this study showed that the average noise levels experienced by firefighters was below generally accepted guidelines.

  20. Development and Evaluation of Curriculum and Media to Train Part-Time Fire Service Instructors in Rural Areas.

    ERIC Educational Resources Information Center

    Kloss, Frank E.

    The report briefly describes a project whose purpose was to provide guidance and training for rural volunteer fire chiefs and firefighters in Wisconsin to increase the knowledge and skills they use to protect lives and property. The training was provided by part-time instructors who taught and demonstrated the courses and curriculum to suit the…

  1. 76 FR 13401 - Environmental Impact Statements; Notice of Availability

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-11

    ... Mine Pits, Haul Roads, Water Management Structures, and Overburden Disposal Areas, Implementation..., Final EIS, TVA, KY, Tennessee Valley Authority (TVA) Integrated Resource Plan (IRP), To Address the... Activities, Proposal to Support and Conduct Current, Emerging, and Future Training Activities, Implementation...

  2. A Comparison of Current Naval Marksmanship Training Vs. Simulation-Based Marksmanship Training with the Use of Indoor Simulated Marksmanship Trainer (Ismt)

    DTIC Science & Technology

    2014-03-01

    purpose of the study was to determine if the use of a simulator is at least as effective in marksmanship training as traditional dry fire techniques...determine if the use of a simulator is at least as effective in marksmanship training as traditional dry fire techniques. A between-groups study with a...marksmanship. Naval commands could use the information to effectively maintain gun qualifications for inport duty section watch bills and constant anti

  3. Suggested Guide for Fire Service Standard Operating Procedures.

    ERIC Educational Resources Information Center

    Gillett, Merl; Hertzler, Simon L.

    Suggested guidelines for the development of fire service standard operating procedures are presented in this document. Section topics are as follow: chain of command; communications; emergency response; apparatus; fire service training; disaster response; aircraft fire safety; mutual aid; national reporting system (example reporting forms);…

  4. State of Alaska Fire Service Training. Instructor Certification Standards.

    ERIC Educational Resources Information Center

    Hagevig, William

    Designed for local Alaskan fire departments, this pamphlet provides the criteria and qualifications for certificates of firefighter instructors (basic, advanced, master), a list of approved subject categories for each level of certification, sample certification applications, a list of resource publications, and a training course outline (basic…

  5. Fire service and first responder thermal imaging camera (TIC) advances and standards

    NASA Astrophysics Data System (ADS)

    Konsin, Lawrence S.; Nixdorff, Stuart

    2007-04-01

    Fire Service and First Responder Thermal Imaging Camera (TIC) applications are growing, saving lives and preventing injury and property damage. Firefighters face a wide range of serious hazards. TICs help mitigate the risks by protecting Firefighters and preventing injury, while reducing time spent fighting the fire and resources needed to do so. Most fire safety equipment is covered by performance standards. Fire TICs, however, are not covered by such standards and are also subject to inadequate operational performance and insufficient user training. Meanwhile, advancements in Fire TICs and lower costs are driving product demand. The need for a Fire TIC Standard was spurred in late 2004 through a Government sponsored Workshop where experts from the First Responder community, component manufacturers, firefighter training, and those doing research on TICs discussed strategies, technologies, procedures, best practices and R&D that could improve Fire TICs. The workshop identified pressing image quality, performance metrics, and standards issues. Durability and ruggedness metrics and standard testing methods were also seen as important, as was TIC training and certification of end-users. A progress report on several efforts in these areas and their impact on the IR sensor industry will be given. This paper is a follow up to the SPIE Orlando 2004 paper on Fire TIC usage (entitled Emergency Responders' Critical Infrared) which explored the technological development of this IR industry segment from the viewpoint of the end user, in light of the studies and reports that had established TICs as a mission critical tool for firefighters.

  6. Dust, Elemental Carbon and Other Impurities on Central Asian Glaciers: Origin and Radiative Forcing

    NASA Astrophysics Data System (ADS)

    Schmale, J.; Flanner, M.; Kang, S.; Sprenger, M.; Zhang, Q.; Li, Y.; Guo, J.; Schwikowski, M.

    2015-12-01

    In Central Asia, more than 60 % of the population depends on water stored in glaciers and mountain snow. While temperature, precipitation and dynamic processes are key drivers of glacial change, deposition of light absorbing impurities such as mineral dust and black carbon can lead to accelerated melting through surface albedo reduction. Here, we discuss the origin of deposited mineral dust and black carbon and their impacts on albedo change and radiative forcing (RF). 218 snow samples were taken from 13 snow pits on 4 glaciers, Abramov (Pamir), Suek, Glacier No. 354 and Golubin (Tien Shan), representing deposition between summer 2012 and 2014. They were analyzed for elemental and organic carbon by a thermo-optical method, mineral dust by gravimetry, and iron by ICP-MS. Back trajectory ensembles were released every 6 hours with the Lagranto model for the covered period at all sites. Boundary layer "footprints" were calculated to estimate general source regions and combined with MODIS fire counts for potential fire contributions. Albedo reduction due to black carbon and mineral dust was calculated with the Snow-Ice-Aerosol-Radiative model (SNICAR), and surface spectral irradiances were derived from atmospheric radiative transfer calculations to determine the RF under clear-sky and all sky conditions using local radiation measurements. Dust contributions came from Central Asia, the Arabian Peninsula, the Sahara and partly the Taklimakan. Fire contributions were higher in 2014 and generally came from the West and North. We find that EC exerts roughly 3 times more RF than mineral dust in fresh and relatively fresh snow (~5 W/m2) and up to 6 times more in snow that experienced melting (> 10 W/m2) even though EC concentrations (average per snow pit from 90 to 700 ng/g) were up to two orders of magnitude lower than mineral dust (10 to 140 μg/g).

  7. Communicating with wildland interface communities during wildfire

    USGS Publications Warehouse

    Taylor, Jonathan G.; Gillette, Shana C.

    2005-01-01

    Communications during fire events are complex. Nevertheless, training fire information officers to plan fire communications before events, and to communicate during fires in a way that accurately and promptly informs residents in fire-affected areas, can increase effectiveness, reduce anxiety, ensure residents have accurate information on which to act, help them make better decisions, and possibly save lives.

  8. Support Assistants for Fire Emergencies; Student Manual, Part A. Firefighting for Civil Defense Emergencies.

    ERIC Educational Resources Information Center

    International Association of Fire Chiefs, New York, NY.

    A manual intended to help fire departments and Civil Defense organizations train people to support regular fire forces during a national emergency is presented. It contains 11 chapters: Introduction, Modern Weapons and Radioactive Fallout, Role of Fire Service in Civil Defense, Local Fire Department Organization, Role of Support Assistants in…

  9. Inspection. Fire Service Certification Series. Unit FSCS-FF-17-81.

    ERIC Educational Resources Information Center

    Pribyl, Paul F.

    This training unit on inspection is part of a 17-unit course package written to aid instructors in the development, teaching, and evaluation of fire fighters in the Wisconsin Fire Service Certification Series. The purpose stated for the 4.5-hour unit is to give the fire fighters an insight into their responsibilities concerning fire prevention and…

  10. Removal of Invasive Fire-Prone Grasses to Increase Training Lands in the Pacific

    DTIC Science & Technology

    2008-09-01

    Boone Kauffman. U.S. Forest Service. Pacific Northwest Research Center. Hilo . Hawaii . SWCA, Inc. 39 SWCA also acknowledges Amy Brown Curtis...Marine Corps Base Hawaii (MCBH), Marine Corps Training Area Bellows (MCTAB), Army installations Makua Valley, Schofield Barracks, Pohakuloa Training...Area, the Hawaii Army National Guard facility at Diamond Head Crater, and at the Naval Magazine on the Island of Guam. Invasive, fire-prone

  11. Temporal Geophysical Investigations of the FT-2-Plume at the Wurtsmith Air Force Base, Oscoda, Michigan

    EPA Science Inventory

    The decommissioned Wurtsmith Air Force Base former Fire Training Cell (FT-02) facility has been the focus of several geophysical investigations. After several decades of fire training exercises, significant amounts of hydrocarbons and some solvents seeped into the subsurface cont...

  12. TEMPORAL GEOPHYSICAL INVESTIGATIONS OF THE FT-2-PLUME AT THE WURTSMITH AIR FORCE BASE, OSCODA, MICHIGAN

    EPA Science Inventory

    The decommissioned Wurtsmith Air Force Base former Fire Training Cell (FT-02) facility has been the focus of several geophysical investigations. After several decades of fire training exercises, significant amounts of hydrocarbons and some solvents seeped into the Subsurface cont...

  13. Fire management assessment of Eastern Province, Zambia

    Treesearch

    L. T. Hollingsworth; D. Johnson; G. Sikaundi; S. Siame

    2015-01-01

    The mission that produced this assessment was prompted by requests from Forestry Department personnel in Zambia to the United States Agency for International Development (USAID) for formal fire management training. USAID contacted the United States Forest Service's (USFS) International Programs (IP) with the training request. Together, USFS, USAID, and Zambian...

  14. Firefighters from Mayport Naval Station train at CCAFS

    NASA Technical Reports Server (NTRS)

    2000-01-01

    Firefighters surround a burning simulated aircraft during training exercises Cape Canaveral Air Force Station Pad 30. Those at left wait their turn as the crew on the right turn their hoses toward the fire. The firefighters are with Fire and Emergency Services at the Naval Station Mayport, Fla.

  15. Assessment of Small Arms Munitions Impacts on Natural Infrastructure in Sensitive Downrange Areas on Military Installations

    DTIC Science & Technology

    2016-02-01

    forecasting the risk of munitions constituents (MC), such as high explosives and metals , that leave firing and training ranges and contaminate the...quality terrestrial natural infrastructure exist down- range of small arms training ranges on Department of Defense (DoD) in- stallations. Live- fire ...CERL TN-16-1 iv Illustrations Figures A-1 Initial horizontal trajectory of a tracer bullet fired at a 600 m target at the Malone 5 range on Fort

  16. Trial by Fire (and Tornado) Taught Us to Plan for Crises.

    ERIC Educational Resources Information Center

    Caylor, Mary Jane

    1991-01-01

    Based on Huntsville (Alabama) schools' experience with a devastating fire, the superintendent later ensured adequate fire insurance coverage, promoted regular fire drills, and developed an emergency response plan that delineated staff responsibilities, communication modes, and training and updating procedures. The plan served the district well…

  17. 14 CFR 121.417 - Crewmember emergency training.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... crewmember combats an actual or simulated fire using at least one type of installed hand fire extinguisher or... by paragraph (d) of this section for combatting fires aboard airplanes; (ii) At least one approved firefighting drill in which the crewmember combats an actual fire using at least one type of installed hand...

  18. Fire Prevention Inspection Procedures.

    ERIC Educational Resources Information Center

    Pribyl, Paul F.

    Lesson plans are provided for a fire prevention inspection course of the Wisconsin Fire Service Training program. Objectives for the course are to enable students to describe and conduct fire prevention inspections, to identify and correct hazards common to most occupancies, to understand the types of building construction and occupancy, and to…

  19. Keeping Haines Real - Or Really Changing Haines?

    Treesearch

    Brian E. Potter; Dan Borsum; Don Haines

    2002-01-01

    Most incident command teams can handle low- to moderate-intensity fires with few unanticipated problems. However, high-intensity situations, especially the plume-dominated fires that often develop when winds are low and erratic behavior is unexpected, can create dangerous situations even for well-trained, experienced fire crews (Rothermel 1991). Plume-dominated fires...

  20. LVQ and backpropagation neural networks applied to NASA SSME data

    NASA Technical Reports Server (NTRS)

    Doniere, Timothy F.; Dhawan, Atam P.

    1993-01-01

    Feedfoward neural networks with backpropagation learning have been used as function approximators for modeling the space shuttle main engine (SSME) sensor signals. The modeling of these sensor signals is aimed at the development of a sensor fault detection system that can be used during ground test firings. The generalization capability of a neural network based function approximator depends on the training vectors which in this application may be derived from a number of SSME ground test-firings. This yields a large number of training vectors. Large training sets can cause the time required to train the network to be very large. Also, the network may not be able to generalize for large training sets. To reduce the size of the training sets, the SSME test-firing data is reduced using the learning vector quantization (LVQ) based technique. Different compression ratios were used to obtain compressed data in training the neural network model. The performance of the neural model trained using reduced sets of training patterns is presented and compared with the performance of the model trained using complete data. The LVQ can also be used as a function approximator. The performance of the LVQ as a function approximator using reduced training sets is presented and compared with the performance of the backpropagation network.

  1. Firefighters from Mayport Naval Station train at CCAFS

    NASA Technical Reports Server (NTRS)

    2000-01-01

    A firefighter (right) holds a water hose in readiness as others enter a smoke-filled simulated aircraft. The activities are part of fire training exercises at Cape Canaveral Air Force Station Pad 30 for firefighters with Fire and Emergency Services at the Naval Station Mayport, Fla. The firefighters have already extinguished flames from the aircraft.

  2. Effects of coal mine subsidence in the Sheridan, Wyoming, area

    USGS Publications Warehouse

    Dunrud, C. Richard; Osterwald, Frank W.

    1980-01-01

    Analyses of the surface effects of past underground coal mining in the Sheridan, Wyoming, area suggest that underground mining of strippable coal deposits may damage the environment more over long periods of time than would modern surface mining, provided proper restoration procedures are followed after surface mining. Subsidence depressions and pits are a continuing hazard to the environment and to man's activities in the Sheridan, Wyo., area above abandoned underground mines in weak overburden less than about 60 m thick and where the overburden is less than about 10-15 times the thickness of coal mined. In addition, fires commonly start by spontaneous ignition when water and air enter the abandoned mine workings via subsidence cracks and pits. The fires can then spread to unmined coal as they create more cavities, more subsidence, and more cracks and pits through which air can circulate. In modern surface mining operations the total land surface underlain by minable coal is removed to expose the coal. The coal is removed, the overburden and topsoil are replaced, and the land is regraded and revegetated. The land, although disturbed, can be more easily restored and put back into use than can land underlain by abandoned underground mine workings in areas where the overburden is less than about 60 m thick or less than about 10-15 times the thickness of coal mined. The resource recovery of modern surface mining commonly is much greater than that of underground mining procedures. Although present-day underground mining technology is advanced as compared to that of 25-80 years ago, subsidence resulting from underground mining of thick coal beds beneath overburden less than about 60 m thick can still cause greater damage to surface drainage, ground water, and vegetation than can properly designed surface mining operations. This report discusses (11 the geology and surface and underground effects of former large-scale underground coal mining in a 50-km 2 area 5-20 km north of Sheridan, Wyo., (2) a ground and aerial reconnaissance study of a 5-km^2 coal mining area 8-10 km west of Sheridan, and (31 some environmental consequences and problems caused by coal mining.

  3. Physical fitness of an industrial fire department vs. a municipal fire department.

    PubMed

    Garver, Julie N; Jankovitz, Kristine Z; Danks, Jane M; Fittz, Ashley A; Smith, Heather S; Davis, Steven C

    2005-05-01

    Both industrial and municipal firefighters need to maintain high levels of physical fitness and minimize cardiovascular risk factors. The nature of firefighter responsibilities in industrial and municipal settings may vary, affecting the ability to sustain high levels of physical fitness. We compared the working conditions, physical fitness, and exercise training practices of an industrial fire department (n = 17) to those of a nearby municipal fire department (n = 55). After informed consent, aerobic capacity, muscular strength, muscular endurance, body composition, flexibility, blood lipid concentrations, and blood pressure levels were measured. Exercise training practices and related factors were assessed using a questionnaire. Despite programmatic differences, these departments demonstrated similar, relatively high degrees of physical fitness and similar blood lipid concentrations, blood pressure levels, and cardiac risk factors. It is recommended that fire departments involve appropriately trained staff, schedule on-duty times for exercise, offer well-equipped exercise facilities, and follow National Strength and Conditioning Association (NSCA) and American College of Sports Medicine (ACSM) guidelines for exercise conditioning in order to maintain a high degree of physical fitness.

  4. Pavlovian-to-instrumental transfer: A new paradigm to assess pathological mechanisms with regard to the use of Internet applications.

    PubMed

    Vogel, Verena; Kollei, Ines; Duka, Theodora; Snagowski, Jan; Brand, Matthias; Müller, Astrid; Loeber, Sabine

    2018-07-16

    At present, there is a considerable lack of human studies that investigated the impact of conditioned cues on instrumental responding although these processes are considered as core mechanisms contributing to the development and maintenance of addictive behaviours. No studies are available that assessed these processes with regard to Internet gaming or Internet shopping applications. We thus developed a Pavlovian-to-instrumental transfer (PIT)-Paradigm implementing appetitive stimuli related to Internet gaming and Internet shopping applications and investigated whether an outcome-specific PIT-Effect is observed. In addition, we assessed whether the problematic use of gaming or shopping applications, personality traits and stress would affect the acquisition of knowledge of the experimental contingencies during Pavlovian training and the impact of conditioned stimuli on instrumental responding. A PIT-Paradigm, screenings for Internet gaming disorder and Internet shopping disorder (s-IAT), and questionnaires on personality traits (NEO-FFI, BIS-15) and perceived stress (PSQ20) were administered to sixty-six participants. The PIT-Paradigm demonstrated the effects of stimuli conditioned to rewards related to Internet gaming and Internet shopping applications on instrumental responding to obtain such rewards. Findings also indicated that severity of problematic Internet gaming, but not Internet shopping, contributed to the acquisition of knowledge of the experimental contingencies. Stress, extraversion, neuroticism and gender emerged as further predictors. The strength of expectancy of the different reinforcers affected the 'gaming PIT'-Effect; however, none of the variables assessed in the present study showed any effect on the 'shopping PIT'-Effect. Future studies including participants with pathological use patterns that can be classified as internet use disorder are warranted to extend these findings. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Neural correlates of Pavlovian-to-instrumental transfer in the nucleus accumbens shell are selectively potentiated following cocaine self-administration

    PubMed Central

    Saddoris, Michael P.; Stamatakis, Alice; Carelli, Regina M.

    2013-01-01

    During Pavlovian-to-instrumental transfer (PIT), learned Pavlovian cues significantly modulate ongoing instrumental actions. This phenomenon is suggested as a mechanism under which conditioned stimuli may lead to relapse in addicted populations. Following discriminative Pavlovian learning and instrumental conditioning with sucrose, one group of rats (naive) underwent electrophysiological recordings in the nucleus accumbens core and shell during a single PIT session. Other groups, following Pavlovian and instrumental conditioning, were subsequently trained to self-administer cocaine with nosepoke responses, or received yoked saline infusions and nosepoked for water rewards, and then performed PIT while electrophysiological recordings were taken in the nucleus accumbens. Behaviorally, although both naive and saline-treated groups showed increases in lever pressing during the conditioned stimulus cue, this effect was significantly enhanced in the cocaine-treated group. Neurons in the core and shell tracked these behavioral changes. In control animals, core neurons were significantly more likely to encode general information about cues, rewards and responses than those in the shell, and positively correlated with behavioral PIT performance, whereas PIT-specific encoding in the shell, but not core, tracked PIT performance. In contrast, following cocaine exposure, there was a significant increase in neural encoding of all task-relevant events that was selective to the shell. Given that cocaine exposure enhanced both behavior and shell-specific task encoding, these findings suggest that, whereas the core is important for acquiring the information about cues and response contingencies, the shell is important for using this information to guide and modulate behavior and is specifically affected following a history of cocaine self-administration. PMID:21507084

  6. Fire Protection for Rural Communities.

    ERIC Educational Resources Information Center

    Hagevig, William A.

    Fire protection in rural Alaskan communities depends on individual home fire prevention and protection rather than on the services offered by a centralized fire department. Even when help is summoned to extinguish a blaze, aid does not come in the form of a cadre of highly trained firefighters; it comes instead from whomever happens to be in the…

  7. Fire Rescue Exercise

    NASA Image and Video Library

    2014-03-06

    CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters, wearing protective gear, use hoses to put out a fire burning close to a mock-up of a small plane. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett

  8. Fire Rescue Exercise

    NASA Image and Video Library

    2014-03-06

    CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters, wearing protective gear, use hoses to put out a fire burning near the mock-up of a small plane. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett

  9. Fire Rescue Exercise

    NASA Image and Video Library

    2014-03-06

    CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters, wearing protective gear, use hoses to put out a fire burning on a mock-up of a small plane. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett

  10. Fire Rescue Exercise

    NASA Image and Video Library

    2014-03-06

    CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters use fire trucks and hoses to extinguish flames burning on and around a mock-up of a small plane. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett

  11. The bay area wildfire forum

    Treesearch

    Todd E. Bruce

    1995-01-01

    Fire agencies throughout the San Francisco Bay Area formed a grassroots organization to influence a firesafe environment. The Bay Area Wildfire Forum (BAWF) was organized in 1992 to coordinate wildland fire training while promoting and encouraging further activities regarding wildland firefighting and fire prevention.

  12. Fire Safety of Passenger Trains : Phase II : Application of Fire Hazard Analysis Techniques

    DOT National Transportation Integrated Search

    2001-12-01

    On May 12, 1999, the Federal Railroad Administration (FRA) issued regulations for passenger rail equipment safety standards that included small-scale fire tests and performance criteria to evaluate the flammability and smoke characteristics of indivi...

  13. Fire safety of passenger trains. Phase II, Application of fire hazard analysis techniques.

    DOT National Transportation Integrated Search

    2001-12-01

    On May 12, 1999, the Federal Railroad Administration (FRA) issued regulations for passenger rail equipment safety standards that included small-scale fire tests and performance criteria to evaluate the flammability and smoke characteristics of indivi...

  14. Residence Hall Fires.

    ERIC Educational Resources Information Center

    Wright, Dorothy

    1999-01-01

    Discusses how one college's experience with a tragic fire in one of its residence halls prompted a reevaluation of its fire-prevention-and-response strategies. Staff training, sprinkler installation, new alarm systems, and exit hardware to help make building exiting more efficient are discussed. (GR)

  15. KSC00pp1447

    NASA Image and Video Library

    2000-09-14

    KENNEDY SPACE CENTER, FLA. -- Firefighters in full gear douse a fire on a simulated aircraft. The firefighters, who are with Fire and Emergency Services at the Naval Station Mayport, Fla., are taking part in fire training exercises at Cape Canaveral Air Force Station Pad 30.

  16. KSC-00pp1447

    NASA Image and Video Library

    2000-09-14

    KENNEDY SPACE CENTER, FLA. -- Firefighters in full gear douse a fire on a simulated aircraft. The firefighters, who are with Fire and Emergency Services at the Naval Station Mayport, Fla., are taking part in fire training exercises at Cape Canaveral Air Force Station Pad 30.

  17. Korean Affairs Report.

    DTIC Science & Technology

    1986-07-18

    a football ground, a 400-meter track, a jumping pit, training grounds for various events and gymnastic rooms. The tiers of seats are roofed with a...also at the airport. [Text] [Pyongyang KCNA in English 1054 GMT 21 Jun 86 SK] /12913 WPK DELEGATION IN PERU—Pyongyang 23 June (KCNA)— Peruvian

  18. Identity and distribution of residues of energetic compounds at army live-fire training ranges.

    PubMed

    Jenkins, Thomas F; Hewitt, Alan D; Grant, Clarence L; Thiboutot, Sonia; Ampleman, Guy; Walsh, Marianne E; Ranney, Thomas A; Ramsey, Charles A; Palazzo, Antonio J; Pennington, Judith C

    2006-05-01

    Environmental investigations have been conducted at 23 military firing ranges in the United States and Canada. The specific training facilities most frequently evaluated were hand grenade, antitank rocket, and artillery ranges. Energetic compounds (explosives and propellants) were determined and linked to the type of munition used and the major mechanisms of deposition.

  19. Fire. Youth Training Scheme. Core Exemplar Work Based Project.

    ERIC Educational Resources Information Center

    Further Education Staff Coll., Blagdon (England).

    This trainer's guide is intended to assist supervisors of work-based career training projects in teaching students the basics of fire prevention in the kitchen. The guide is one in a series of core curriculum modules that is intended for use in combination on- and off-the-job programs to familiarize youth with the skills, knowledge, and attitudes…

  20. Solution Focused Empathy Training Groups for Students with Fire-Setting Behaviors

    ERIC Educational Resources Information Center

    Froeschle, Janet G.

    2006-01-01

    Fire-setting students are those who intentionally or unintentionally set one or more fires due to curiosity, stress, a need for attention, or due to criminal delinquency. This article describes the nature of fire-setting behaviors, discusses the profile and risk factors associated with the behavior, and outlines a group program using empathy…

  1. Fire Protection Specialist, Blocks I, II, & III, 17-2. Military Curriculum Materials for Vocational and Technical Education.

    ERIC Educational Resources Information Center

    Ohio State Univ., Columbus. National Center for Research in Vocational Education.

    This military-developed text contains the first three blocks of a five-block course for use in training fire protection specialists. Covered in the individual volumes are the following topics: fire protection objectives and responsibilities (fire protection and occupational safety, extinguishing agents, principles and theory of combustion, natural…

  2. Fuel age and fire spread: Natural conditions versus opportunities for fire suppression

    USGS Publications Warehouse

    Halsey, Richard W.; Keeley, Jon E.; Wilson, Kit

    2009-01-01

    Wildfires are driven and restrained by an interplay of variables that can lead to many potential outcomes. As every wildland firefighter learns in basic training, the ability of a fire to spread is determined by three basic variables: fuel type and condition, weather, and topography. Fire suppression obviously plays a significant role in determining fire spread as well, so firefighter activity becomes an additional variable.

  3. Estimation of fire danger in Hawai'i using limited weather data and simulation

    Treesearch

    D.R. Weise; S.L. Stephens; F.M. Fujioka; T.J. Moody; J. Benoit

    2010-01-01

    The presence of fire in Hawai'i has increased with introduction of nonnative grasses. Fire danger estimation using the National Fire Danger Rating System (NFDRS) typically requires 5 to 10 yr of data to determine percentile weather values and fire activity. The U.S. Army Pōhakuloa Training Area in Hawai‘i is located in the interface zone between windward...

  4. Safety in the Chemical Laboratory: Advanced Firemanship: How to Teach Your Audience a Lesson.

    ERIC Educational Resources Information Center

    Pitt, Martin J.

    1984-01-01

    Provides tips to assist in preparing a training program designed to show that: (1) fire is dangerous; (2) ordinary individuals can neither understand fire nor extinguish it; and (3) a fire safety officer can do both. (JN)

  5. Fire Safety for the Oral and Maxillofacial Surgeon and Surgical Staff.

    PubMed

    Di Pasquale, LisaMarie; Ferneini, Elie M

    2017-05-01

    Fire in the operating room is a life-threatening emergency that demands quick, efficient intervention. Because the circumstances surrounding fires are generally well-understood, virtually every operating room fire is preventable. Before every operating room case, thorough preprocedure "time outs" should address each team members' awareness of specific fire risks and agreement regarding fire concerns and emergency actions. Fire prevention centers on 3 constituent parts of the fire triad necessary for fire formation. Regular fire drills should guide policies and procedures to prevent surgical fires. Delivering optimal patient care in emergent situations requires surgical team training, practicing emergency roles, and specific actions. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. DETERMINATION OF PERFLUOROCARBOXYLATES IN GROUNDWATER IMPACTED BY FIRE-FIGHTING ACTIVITY. (R821195)

    EPA Science Inventory

    Perfluorinated surfactants are used in aqueous film forming foam (AFFF)
    formulations, which are used to extinguish hydrocarbon-fuel fires. Virtually
    nothing is known about the occurrence of perfluorinated surfactants in the
    environment, in particular, at fire-train...

  7. A Fire Safety Certification System for Board and Care Operators and Staff. SBIR Phase II: Final Report.

    ERIC Educational Resources Information Center

    Walker, Bonnie L.

    This report describes Phase II of a project which developed a system for delivering fire safety training to board and care providers who serve adults with developmental disabilities. Phase II focused on developing and pilot testing a "train the trainers" workshop for instructors and field testing the provider's workshop. Evaluation of…

  8. Support Assistants for Fire Emergencies; Student Manual, Part B. Firefighting for Civil Defense Emergencies.

    ERIC Educational Resources Information Center

    International Association of Fire Chiefs, New York, NY.

    A course designed to develop performance capabilities in the student of the fire service is presented in a manual. Each chapter is designed to give the student a basic understanding of the material covered in class. Specific objectives are: (1) To train "Support Assistant" B personnel to augment and assist firefighters, (2) To train personnel to…

  9. Altering the Mission Statement: The Training of Firefighters as Intelligence Gatherers

    DTIC Science & Technology

    2008-09-01

    estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Washington headquarters Services ...distribution is unlimited 12b. DISTRIBUTION CODE A 13. ABSTRACT (maximum 200 words) The fire service is one of the...safety of our communities. 15. NUMBER OF PAGES 71 14. SUBJECT TERMS Fire Service , first responders, intelligence, firefighter training, awareness

  10. A Naval Marksmanship Training Transfer Study: The Use of Indoor Simulated Marksmanship Trainers to Train for Live Fire

    DTIC Science & Technology

    2012-03-01

    on the standard Navy Handgun Qualification Course. Results partially supported the hypotheses. The simulation group showed greater improvement in MPI...standard Navy Handgun Qualification Course. Results partially supported the hypotheses. The simulation group showed greater improvement in MPI than the...14 3. Navy Handgun Qualification Course Firing Sequence ..................15 F. PROCEDURES

  11. Discovery of novel per- and polyfluoroalkyl substances (PFASs) at a fire fighting training ground and preliminary investigation of their fate and mobility.

    PubMed

    Baduel, Christine; Mueller, Jochen F; Rotander, Anna; Corfield, John; Gomez-Ramos, Maria-José

    2017-10-01

    Aqueous film forming foams (AFFFs) have been released at fire training facilities for several decades resulting in the contamination of soil and groundwater by per- and polyfluoroalkyl substances (PFASs). AFFF compositions are proprietary and may contain a broad range of PFASs for which the chemical structures and degradation products are not known. In this study, high resolution quadrupole-time-of-flight tandem mass spectrometry (LC-QTOF-MS/MS) in combination with data processing using filtering strategies was applied to characterize and elucidate the PFASs present in concrete extracts collected at a fire training ground after the historical use of various AFFF formulations. Twelve different fluorochemical classes, representing more than 60 chemicals, were detected and identified in the concrete extracts. Novel PFASs homologues, unmonitored before in environmental samples such as chlorinated PFSAs, ketone PFSAs, dichlorinated PFSAs and perfluoroalkane sulphonamides (FASAs) were detected in soil samples collected in the vicinity of the fire training ground. Their detection in the soil cores (from 0 to 2 m) give an insight on the potential mobility of these newly identified PFASs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Fire Rescue Exercise

    NASA Image and Video Library

    2014-03-06

    CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida participate in a training exercise at the Shuttle Landing Facility. Firefighters, wearing protective gear, use hoses to put out a fire burning near the mock-up of a small plane as another firefighter checks inside the plane. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett

  13. Sprinklers/Standpipes/Detection Systems. Fire Service Certification Series. Unit FSCS-FF-11-80.

    ERIC Educational Resources Information Center

    Pribyl, Paul F.

    This training unit on sprinklers, standpipes, and detection systems is part of a 17-unit course package written to aid instructors in the development, teaching, and evaluation of fire fighters in the Wisconsin Fire Service Certification Series. The purpose stated for the 6-hour unit is to provide the fire fighter with an understanding of the…

  14. KSC-00pp1441

    NASA Image and Video Library

    2000-09-14

    KENNEDY SPACE CENTER, FLA. -- A Mobile Aircraft Fire Trainer vehicle from Naval Station Mayport, Fla., stands by during fire training exercises at Cape Canaveral Air Force Station Pad 30. In the background is the simulated aircraft that was set on fire for the exercise. Firefighters with the Fire and Emergency Services at the Naval Station (in the background) gather around the site of the extinguished flames.

  15. KSC00pp1441

    NASA Image and Video Library

    2000-09-14

    KENNEDY SPACE CENTER, FLA. -- A Mobile Aircraft Fire Trainer vehicle from Naval Station Mayport, Fla., stands by during fire training exercises at Cape Canaveral Air Force Station Pad 30. In the background is the simulated aircraft that was set on fire for the exercise. Firefighters with the Fire and Emergency Services at the Naval Station (in the background) gather around the site of the extinguished flames.

  16. 76 FR 3178 - Fire Protection in Shipyard Employment Standard; Extension of the Office of Management and Budget...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-19

    ... (paperwork) requirements. In general, the Standard requires employers to develop a written fire safety plan... of the details of the fire safety plan and that employees have been trained as required by the... to post the fire safety plan or to place it in an area accessible to employees to 12 hours for firms...

  17. Fire Rescue Exercise

    NASA Image and Video Library

    2014-03-06

    CAPE CANAVERAL, Fla. - Special Rescue Operations firefighters with NASA Fire Rescue Services in the Protective Services Office at NASA’s Kennedy Space Center in Florida practice firefighting skills at the Shuttle Landing Facility. A firefighter dons protective gear to prepare for the training simulation. Kennedy’s firefighters recently achieved Pro Board Certification in aerial fire truck operations and completed vehicle extrication training using the Jaws of Life. The Protective Services Office is one step closer to achieving certification in vehicle machinery extrication and other rescue skills. Kennedy’s firefighters are with G4S Government Solutions Inc., on the Kennedy Protective Services Contract. Photo credit: NASA/Kim Shiflett

  18. Calibration and validation of the relative differenced Normalized Burn Ratio (RdNBR) to three measures of fire severity in the Sierra Nevada and Klamath Mountains, California, USA

    USGS Publications Warehouse

    Miller, J.D.; Knapp, E.E.; Key, C.H.; Skinner, C.N.; Isbell, C.J.; Creasy, R.M.; Sherlock, J.W.

    2009-01-01

    Multispectral satellite data have become a common tool used in the mapping of wildland fire effects. Fire severity, defined as the degree to which a site has been altered, is often the variable mapped. The Normalized Burn Ratio (NBR) used in an absolute difference change detection protocol (dNBR), has become the remote sensing method of choice for US Federal land management agencies to map fire severity due to wildland fire. However, absolute differenced vegetation indices are correlated to the pre-fire chlorophyll content of the vegetation occurring within the fire perimeter. Normalizing dNBR to produce a relativized dNBR (RdNBR) removes the biasing effect of the pre-fire condition. Employing RdNBR hypothetically allows creating categorical classifications using the same thresholds for fires occurring in similar vegetation types without acquiring additional calibration field data on each fire. In this paper we tested this hypothesis by developing thresholds on random training datasets, and then comparing accuracies for (1) fires that occurred within the same geographic region as the training dataset and in similar vegetation, and (2) fires from a different geographic region that is climatically and floristically similar to the training dataset region but supports more complex vegetation structure. We additionally compared map accuracies for three measures of fire severity: the composite burn index (CBI), percent change in tree canopy cover, and percent change in tree basal area. User's and producer's accuracies were highest for the most severe categories, ranging from 70.7% to 89.1%. Accuracies of the moderate fire severity category for measures describing effects only to trees (percent change in canopy cover and basal area) indicated that the classifications were generally not much better than random. Accuracies of the moderate category for the CBI classifications were somewhat better, averaging in the 50%-60% range. These results underscore the difficulty in isolating fire effects to individual vegetation strata when fire effects are mixed. We conclude that the models presented here and in Miller and Thode ([Miller, J.D. & Thode, A.E., (2007). Quantifying burn severity in a heterogeneous landscape with a relative version of the delta Normalized Burn Ratio (dNBR). Remote Sensing of Environment, 109, 66-80.]) can produce fire severity classifications (using either CBI, or percent change in canopy cover or basal area) that are of similar accuracy in fires not used in the original calibration process, at least in conifer dominated vegetation types in Mediterranean-climate California.

  19. Using Matrix and Tensor Factorizations for the Single-Trial Analysis of Population Spike Trains.

    PubMed

    Onken, Arno; Liu, Jian K; Karunasekara, P P Chamanthi R; Delis, Ioannis; Gollisch, Tim; Panzeri, Stefano

    2016-11-01

    Advances in neuronal recording techniques are leading to ever larger numbers of simultaneously monitored neurons. This poses the important analytical challenge of how to capture compactly all sensory information that neural population codes carry in their spatial dimension (differences in stimulus tuning across neurons at different locations), in their temporal dimension (temporal neural response variations), or in their combination (temporally coordinated neural population firing). Here we investigate the utility of tensor factorizations of population spike trains along space and time. These factorizations decompose a dataset of single-trial population spike trains into spatial firing patterns (combinations of neurons firing together), temporal firing patterns (temporal activation of these groups of neurons) and trial-dependent activation coefficients (strength of recruitment of such neural patterns on each trial). We validated various factorization methods on simulated data and on populations of ganglion cells simultaneously recorded in the salamander retina. We found that single-trial tensor space-by-time decompositions provided low-dimensional data-robust representations of spike trains that capture efficiently both their spatial and temporal information about sensory stimuli. Tensor decompositions with orthogonality constraints were the most efficient in extracting sensory information, whereas non-negative tensor decompositions worked well even on non-independent and overlapping spike patterns, and retrieved informative firing patterns expressed by the same population in response to novel stimuli. Our method showed that populations of retinal ganglion cells carried information in their spike timing on the ten-milliseconds-scale about spatial details of natural images. This information could not be recovered from the spike counts of these cells. First-spike latencies carried the majority of information provided by the whole spike train about fine-scale image features, and supplied almost as much information about coarse natural image features as firing rates. Together, these results highlight the importance of spike timing, and particularly of first-spike latencies, in retinal coding.

  20. Using Matrix and Tensor Factorizations for the Single-Trial Analysis of Population Spike Trains

    PubMed Central

    Onken, Arno; Liu, Jian K.; Karunasekara, P. P. Chamanthi R.; Delis, Ioannis; Gollisch, Tim; Panzeri, Stefano

    2016-01-01

    Advances in neuronal recording techniques are leading to ever larger numbers of simultaneously monitored neurons. This poses the important analytical challenge of how to capture compactly all sensory information that neural population codes carry in their spatial dimension (differences in stimulus tuning across neurons at different locations), in their temporal dimension (temporal neural response variations), or in their combination (temporally coordinated neural population firing). Here we investigate the utility of tensor factorizations of population spike trains along space and time. These factorizations decompose a dataset of single-trial population spike trains into spatial firing patterns (combinations of neurons firing together), temporal firing patterns (temporal activation of these groups of neurons) and trial-dependent activation coefficients (strength of recruitment of such neural patterns on each trial). We validated various factorization methods on simulated data and on populations of ganglion cells simultaneously recorded in the salamander retina. We found that single-trial tensor space-by-time decompositions provided low-dimensional data-robust representations of spike trains that capture efficiently both their spatial and temporal information about sensory stimuli. Tensor decompositions with orthogonality constraints were the most efficient in extracting sensory information, whereas non-negative tensor decompositions worked well even on non-independent and overlapping spike patterns, and retrieved informative firing patterns expressed by the same population in response to novel stimuli. Our method showed that populations of retinal ganglion cells carried information in their spike timing on the ten-milliseconds-scale about spatial details of natural images. This information could not be recovered from the spike counts of these cells. First-spike latencies carried the majority of information provided by the whole spike train about fine-scale image features, and supplied almost as much information about coarse natural image features as firing rates. Together, these results highlight the importance of spike timing, and particularly of first-spike latencies, in retinal coding. PMID:27814363

  1. A Decade of Experience: Which Network Structures Maximize Fire Service Capacity for Homeland Security Incidents in Metropolitan Regions?

    DTIC Science & Technology

    2011-12-01

    Pennsylvania Emergency Management Agency QHSR Quadrennial Homeland Security Review Report RCP Regional Catastrophic Preparedness SAA State...service has evolved from a single-purpose service focused on controlling fires to a multidimensional response element responsible for pre- hospital ... hospital preparedness program Preparedness Training for all personnel; training and network activities during prior year assist in preparedness

  2. Fire Fighter Trainer Environmental Considerations

    DTIC Science & Technology

    1981-01-08

    established by the Environmental Protection Agency and various state and local ordinances. At present, the Navy’s fire fighter train- ing facilities use...necessary. All operational capabilities for military communications equipment have been retained. Each training compartment has a local communications...the state or local air pollution-control agencies on a case-by-case basis. 4.2.4 Japanese Air Pollution-Control Regulations. The Japanese Air Quality

  3. Fire and Life Safety Training Needs of Rail Rapid Transit System and Fire Service Personnel

    DOT National Transportation Integrated Search

    1983-05-01

    This report presents a summary and the results of the successful workshop "On Track to Fire and Life Safety in Rail Rapid Transit," held on August 2-4, 1982, at Crystal City, Virginia. Sponsored by the Urban Mass Transportation Administration (UMTA) ...

  4. Industrial Fire Brigade Training.

    ERIC Educational Resources Information Center

    North Carolina State Dept. of Community Colleges, Raleigh.

    Organized as a teaching outline for an industrial plant fire brigade course, this manual contains a rationale for an industrial plant brigade as an adjunct to the local firefighting services; information to the instructor concerning the implementation of an industrial fire brigade program; and a teaching outline consisting of eleven sections: (1)…

  5. Drill, Baby, Drill

    ERIC Educational Resources Information Center

    Kerkhoff, Todd

    2009-01-01

    School fire drills are quickly becoming insignificant and inconvenient to school administrators. When the time for the monthly fire drill rolls around, it is often performed with a "let's get this over with" attitude. Although all schools conduct fire drills, seldom do they effectively train students and staff members how to respond in a real…

  6. Engineering and Development Program Plan, Aircraft Cabin Fire Safety.

    DTIC Science & Technology

    1980-06-01

    relative to a postcrash fuel fire, or whether advanced materials provide a significant safety benefit in comparison to inservice materials. if either...have always been controlled by early detection and prompt extinguishment action by effectively trained crew members. In addition, the fire resistant...occupants. g. Develop a computer fire test data bank with broad user availability for inservice and candidate cabin interior materials. h. Identify

  7. Computer-Assisted, Programmed Text, and Lecture Modes of Instruction in Three Medical Training Courses: Comparative Evaluation. Final Report.

    ERIC Educational Resources Information Center

    Deignan, Gerard M.; And Others

    This report contains a comparative analysis of the differential effectiveness of computer-assisted instruction (CAI), programmed instructional text (PIT), and lecture methods of instruction in three medical courses--Medical Laboratory, Radiology, and Dental. The summative evaluation includes (1) multiple regression analyses conducted to predict…

  8. Environmental Assessment for Explosives Ordnance Disposal Proficiency Training Range at Wright-Patterson Air Force Base, Ohio

    DTIC Science & Technology

    2010-06-01

    s) __ Test Plt(s) __ Test Trench(es) __ Deep Test(s) __ PZ or Humus Removal __ Testing/Excav. (strategy unknown) __ Mitigation/Block Excavation...Collection __ Surface Collection _Auger/Soil Corer _Shovel Test (s) .lL... Test Pit (s) _Test Trench (es) __ Deep Test (s) _ PZ or Humus Removal

  9. Effect of autogenic training on cardiac autonomic nervous activity in high-risk fire service workers for posttraumatic stress disorder.

    PubMed

    Mitani, Satoko; Fujita, Masatoshi; Sakamoto, Satoko; Shirakawa, Taro

    2006-05-01

    We investigated the effect of autogenic training (AT) on cardiac autonomic nervous activity in fire services workers with the use of the questionnaire of the Japanese-language version of Impact of Event Scale-Revised (IES-R-J) and indexes of heart rate variability. We studied 22 male fire services workers who were divided into posttraumatic stress disorder (PTSD)-related stress group (n=10) and control group (n=12). They underwent AT twice or three times a week for 2 months. Posttraumatic stress disorder-related stress group showed a significantly higher cardiac sympathetic nervous activity and a significantly lower cardiac parasympathetic nervous activity than control group at baseline. Autogenic training significantly decreased cardiac sympathetic nervous activity and significantly increased cardiac parasympathetic nervous activity in both groups. These changes were accompanied by a significant decrease in the total points of IES-R-J. Autogenic training is effective for ameliorating the disturbance of cardiac autonomic nervous activity and psychological issues secondary to PTSD.

  10. Dynamics and Physiological Roles of Stochastic Firing Patterns Near Bifurcation Points

    NASA Astrophysics Data System (ADS)

    Jia, Bing; Gu, Huaguang

    2017-06-01

    Different stochastic neural firing patterns or rhythms that appeared near polarization or depolarization resting states were observed in biological experiments on three nervous systems, and closely matched those simulated near bifurcation points between stable equilibrium point and limit cycle in a theoretical model with noise. The distinct dynamics of spike trains and interspike interval histogram (ISIH) of these stochastic rhythms were identified and found to build a relationship to the coexisting behaviors or fixed firing frequency of four different types of bifurcations. Furthermore, noise evokes coherence resonances near bifurcation points and plays important roles in enhancing information. The stochastic rhythms corresponding to Hopf bifurcation points with fixed firing frequency exhibited stronger coherence degree and a sharper peak in the power spectrum of the spike trains than those corresponding to saddle-node bifurcation points without fixed firing frequency. Moreover, the stochastic firing patterns changed to a depolarization resting state as the extracellular potassium concentration increased for the injured nerve fiber related to pathological pain or static blood pressure level increased for aortic depressor nerve fiber, and firing frequency decreased, which were different from the physiological viewpoint that firing frequency increased with increasing pressure level or potassium concentration. This shows that rhythms or firing patterns can reflect pressure or ion concentration information related to pathological pain information. Our results present the dynamics of stochastic firing patterns near bifurcation points, which are helpful for the identification of both dynamics and physiological roles of complex neural firing patterns or rhythms, and the roles of noise.

  11. Development of turbomachinery trains for the CASHING, NGCASH, and IGCASH cycle applications: Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaul, G.; Nakhamkin, M.; Swensen, E.

    1994-12-01

    Turbomachinery trains were conceptually developed for three power plant concepts: Compressed Air Storage with Humidification and Integrated Gasification and Natural Gas Firing (CASHING), Natural Gas fired Compressed Air Storage with Humidification (NGCASH), and Integrated Gasification fired Compressed Air Storage with Humidification (IGCASH). Performance data, arrangement drawings, cost estimates, and other technical information for the three turboexpander trains were developed based on the Westinghouse BB51 steam turbine for the high pressure expander and the expander section of the W501F or W501D5 combustion turbine for the low pressure expander. The study supports previous EPRI projects investigating the performance and cost of CASHING,more » NGCASH, and IGCASH concepts and provides a basis for quotations that can be used in evaluating compressed air energy storage concepts in future projects.« less

  12. Prescribed Fire and Fire Suppression Training in the U.S. Fish and Wildlife Service for the Year 2010

    Treesearch

    James L. Murphy; Frank T. Cole

    1987-01-01

    The Fish and Wildlife Service, U.S. Department of the Interior, uses prescribed fire for habitat improvement on over 400 National Wildlife Refuges across the United States. Wildfire is a problem on some refuges. Escaped fires have resulted in fatalities and the loss of millions of dollars in natural and man-made resources. The Service recognized the critical need for...

  13. Effects of injection position and transponder size on the performances of passive injectable transponders used for the electronic identification of cattle.

    PubMed

    Conill, C; Caja, G; Nehring, R; Ribó, O

    2000-12-01

    A total of 686 Tiris half-duplex passive injectable transponders (PIT) of two sizes (23 and 32 mm) were randomly injected s.c. in three positions, armpit, ear scutulum, and upper lip, in 343 fattening calves (1 to 3 mo old). Injections were performed by two trained and two untrained operators. Losses and breakages on the farm were recorded at wk 1, 3, 7, 11, and 15 in restrained animals using two types of hand-held transceivers with a stick antenna. Dynamic reading efficiency (DRE) in animals running through a raceway was also evaluated at wk 1 and 3 and monthly until slaughter, using a stationary transceiver working at 137 dB x microV x m(-1) at 3 m. The total number of PIT that fell or broke in the slaughtering line, the location method, and the recovery time were also recorded. Results on the farm showed low breakages on average (0.4%) and differences (P < 0.05) in losses according to position (armpit, 1.7%; ear, 5.2%; and lip, 14.0%). An interaction (P < 0.05) between position x size was observed, and losses were greatest using a 32-mm PIT in the lip. The DRE was affected (P < 0.05) by PIT position and size, and values were greater for the 32-mm PIT in all positions (armpit: 99.9 +/- 0.1 vs 95.8 +/- 4.9%; ear: 93.8 +/- 2.2 vs 81.9 +/- 4.6%; lip: 66.8 +/- 4.9 vs 53.4 +/- 4.7%, respectively, for 32 vs 23 mm). Recovery of PIT in the abattoir was on average 96.7, 96.7, and 99.2% for armpit, ear, and lip, respectively (P > 0.05). Most of the PIT injected in the armpit were recovered by sight or palpation, but 31.9% were recovered after cutting the muscles around the area and 10.7% were recovered on the internal side of the hide, which jeopardized carcass identification. Recovery of PIT injected in the ear was 23.4% in the hide and 76.6% in the auricular muscles of the head. The easiest recovery was in the lip, 8.9% of PIT were located in the hide and 91.1% in the head. Recovery time was affected (P < 0.05) by position: the quickest was lip (27 +/- 2 s), followed by ear (52 +/- 5 s) and armpit (78 +/- 7 s). In conclusion, taking into account retention and reading performances, injection of a 32-mm PIT into the armpit showed the best results on the farm, but a careful and longer recovery was needed in the abattoir. Improvement of recovery methodology and time would be necessary in order to recommend injection of PIT in the armpit instead of in the ear for cattle tracking or monitoring.

  14. Does training under consistent mapping conditions lead to automatic attention attraction to targets in search tasks?

    PubMed

    Lefebvre, Christine; Cousineau, Denis; Larochelle, Serge

    2008-11-01

    Schneider and Shiffrin (1977) proposed that training under consistent stimulus-response mapping (CM) leads to automatic target detection in search tasks. Other theories, such as Treisman and Gelade's (1980) feature integration theory, consider target-distractor discriminability as the main determinant of search performance. The first two experiments pit these two principles against each other. The results show that CM training is neither necessary nor sufficient to achieve optimal search performance. Two other experiments examine whether CM trained targets, presented as distractors in unattended display locations, attract attention away from current targets. The results are again found to vary with target-distractor similarity. Overall, the present study strongly suggests that CM training does not invariably lead to automatic attention attraction in search tasks.

  15. A WSN-based tool for urban and industrial fire-fighting.

    PubMed

    De San Bernabe Clemente, Alberto; Martínez-de Dios, José Ramiro; Ollero Baturone, Aníbal

    2012-11-06

    This paper describes a WSN tool to increase safety in urban and industrial fire-fighting activities. Unlike most approaches, we assume that there is no preexisting WSN in the building, which involves interesting advantages but imposes some constraints. The system integrates the following functionalities: fire monitoring, firefighter monitoring and dynamic escape path guiding. It also includes a robust localization method that employs RSSI-range models dynamically trained to cope with the peculiarities of the environment. The training and application stages of the method are applied simultaneously, resulting in significant adaptability. Besides simulations and laboratory tests, a prototype of the proposed system has been validated in close-to-operational conditions.

  16. Information-Seeking and Sharing Behaviors among Fire Service Field Staff Instructors: A Qualitative Study

    ERIC Educational Resources Information Center

    Ruan, Lian J.

    2011-01-01

    Fire service field staff instructors seek and share information and use information sources during their instructional work of teaching, training and curriculum development. This study is the first attempt to study their information-seeking and sharing behaviors, which have not previously been investigated empirically. Twenty-five fire service…

  17. Prescribed Fire Education at Oklahoma State University: Training Our Future Pyros

    Treesearch

    John R. Weir

    2008-01-01

    The Rangeland Ecology and Management program at Oklahoma State University recognized the need for a practical, hands-on course designed for undergraduate and graduate students, with instruction on conducting prescribed fires for vegetation management, wildlife management, and livestock management. Two separate prescribed fire courses were initiated in the spring of...

  18. Guidelines for Fire Service Education Programs in Community and Junior Colleges.

    ERIC Educational Resources Information Center

    Favreau, Donald F.

    This report serves as a guideline for fire service education. For men filling the estimated 10,000 opportunities in career fire department organizations each year in the 1970s, it is necessary that they receive a supplement to department-level training in drills and skills. Knowledge of hydraulics, chemistry, mechanical engineering, law…

  19. Guidance on spatial wildland fire analysis: models, tools, and techniques

    Treesearch

    Richard D. Stratton

    2006-01-01

    There is an increasing need for spatial wildland fire analysis in support of incident management, fuel treatment planning, wildland-urban assessment, and land management plan development. However, little guidance has been provided to the field in the form of training, support, or research examples. This paper provides guidance to fire managers, planners, specialists,...

  20. Charcoal records reveal past occurrences of disturbances in the forests of the Kisangani region, Democratic Republic of the Congo

    NASA Astrophysics Data System (ADS)

    Tshibamba Mukendi, John; Hubau, Wannes; Ntahobavuka, Honorine; Boyemba Bosela, Faustin; De Cannière, Charles; Beeckman, Hans

    2014-05-01

    Past disturbances have modified local density, structure and floristic composition of Central African rainforests. As such, these perturbations represent a driving force for forest dynamics and they were presumably at the origin of present-day forest mosaics. One of the most prominent disturbances within the forest is fire, leaving behind charcoal as a witness of past forest dynamics. Quantification and identification of ancient charcoal fragments found in soil layers (= pedoanthracology) allows a detailed reconstruction of forest history, including the possible occurrence of past perturbations. The primary objective of this study is to present palaeoenvironmental evidence for the existence of past disturbances in the forests of the Kisangani region (Democratic Republic of the Congo) using a pedoanthracological approach. We quantified and identified charcoal fragments from pedoanthracological excavations in the Yangambi, Yoko, Masako and Kole forest regions. Charcoal sampling was conducted in pit intervals of 10 cm, whereby pottery fragments were also registered and quantified. Floristic identifications were conducted using former protocols based on wood anatomy, which is largely preserved after charcoalification. 14 excavations were conducted and charcoal was found in most pit intervals. Specifically, 52 out of 56 sampled intervals from the Yangambi forest contained charcoal, along with 47 pit intervals from the Yoko forest reserve, 34 pit intervals from the Masako forest and 16 from the Kole forest. Highest specific anthracomasses were recorded in Yoko (167 mg charcoal per kg soil), followed by Yangambi (133 mg/kg), Masako (71,89 mg/kg) and finally Kole (42,4 mg/kg). Charcoal identifications point at a manifest presence of the family of Fabaceae (Caesalpinioideae). This family is characteristic for the tropical humid rainforest. The presence of charcoal fragments from these taxa, associated with pottery sherds on different depths within the profiles, suggests past occurrences of anthropogenic perturbations in these forests. Insights in past forest dynamics and the relative roles of climatic and anthropogenic disturbances enhance our overall understanding of present and future forest dynamics.

  1. Fire fighting and its influence on the body.

    PubMed

    Rossi, René

    2003-08-15

    Working conditions for fire fighters can be described according to the environment temperature and the incident radiant heat flux. Measurements for this study in buildings for fire fighting training have shown that fire fighters are typically exposed to radiant heat fluxes of between 5 and 10 kWm(-2) during this kind of exercise. The heat load can nevertheless be much higher. In one case, 42 kWm(-2) was measured. The temperatures reached between 100 and 190 degrees C at 1 m above ground, going up to 278 degrees C in one case. Human trials have been performed with 17 fire fighters. After exercises (about 15 min) in a heated room, the mean core temperature of the fire fighters rose by 0.6 degrees C with a surrounding temperature of 31 degrees C and 1.0 degrees C with 38 degrees C. The sweat production varied from 0.7 to 2.1 lh(-1); 16% to 45% of sweat remained in the clothing layers. During the exercises in the training buildings, a mean of 48 degrees C has been measured between fire fighters' clothing and workwear. These conditions lead to an increase of the relative humidity in all the jackets up to 100%. When the fire fighters came out of the fire, the humidity remained at this level in the PVC coated jackets while it was in some cases strongly reduced in breathable jackets.

  2. High explosive spot test analyses of samples from Operable Unit (OU) 1111

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McRae, D.; Haywood, W.; Powell, J.

    1995-01-01

    A preliminary evaluation has been completed of environmental contaminants at selected sites within the Group DX-10 (formally Group M-7) area. Soil samples taken from specific locations at this detonator facility were analyzed for harmful metals and screened for explosives. A sanitary outflow, a burn pit, a pentaerythritol tetranitrate (PETN) production outflow field, an active firing chamber, an inactive firing chamber, and a leach field were sampled. Energy dispersive x-ray fluorescence (EDXRF) was used to obtain semi-quantitative concentrations of metals in the soil. Two field spot-test kits for explosives were used to assess the presence of energetic materials in the soilmore » and in items found at the areas tested. PETN is the major explosive in detonators manufactured and destroyed at Los Alamos. No measurable amounts of PETN or other explosives were detected in the soil, but items taken from the burn area and a high-energy explosive (HE)/chemical sump were contaminated. The concentrations of lead, mercury, and uranium are given.« less

  3. 49 CFR 194.117 - Training.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Training. 194.117 Section 194.117 Transportation... Response Plans § 194.117 Training. (a) Each operator shall conduct training to ensure that: (1) All... of equipment, fire suits, and breathing apparatus. (b) Each operator shall maintain a training record...

  4. 49 CFR 194.117 - Training.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Training. 194.117 Section 194.117 Transportation... Response Plans § 194.117 Training. (a) Each operator shall conduct training to ensure that: (1) All... of equipment, fire suits, and breathing apparatus. (b) Each operator shall maintain a training record...

  5. Immersive virtual reality-based training improves response in a simulated operating room fire scenario.

    PubMed

    Sankaranarayanan, Ganesh; Wooley, Lizzy; Hogg, Deborah; Dorozhkin, Denis; Olasky, Jaisa; Chauhan, Sanket; Fleshman, James W; De, Suvranu; Scott, Daniel; Jones, Daniel B

    2018-01-25

    SAGES FUSE curriculum provides didactic knowledge on OR fire prevention. The objective of this study is to evaluate the impact of an immersive virtual reality (VR)-based OR fire training simulation system in combination with FUSE didactics. The study compared a control with a simulation group. After a pre-test questionnaire that assessed the baseline knowledge, both groups were given didactic material that consists of a 10-min presentation and reading materials about precautions and stopping an OR fire from the FUSE manual. The simulation group practiced on the OR fire simulation for one session that consisted of five trials within a week from the pre-test. One week later, both groups were reassessed using a questionnaire. A week after the post-test both groups also participated in a simulated OR fire scenario while their performance was videotaped for assessment. A total of 20 subjects (ten per group) participated in this IRB approved study. Median test scores for the control group increased from 5.5 to 9.00 (p = 0.011) and for the simulation group it increased from 5.0 to 8.5 (p = 0.005). Both groups started at the same baseline (pre-test, p = 0.529) and reached similar level in cognitive knowledge (post-test, p = 0.853). However, when tested in the mock OR fire scenario, 70% of the simulation group subjects were able to perform the correct sequence of steps in extinguishing the simulated fire whereas only 20% subjects in the control group were able to do so (p = 0.003). The simulation group was better than control group in correctly identifying the oxidizer (p = 0.03) and ignition source (p = 0.014). Interactive VR-based hands-on training was found to be a relatively inexpensive and effective mode for teaching OR fire prevention and management scenarios.

  6. Mapping Fire Severity Using Imaging Spectroscopy and Kernel Based Image Analysis

    NASA Astrophysics Data System (ADS)

    Prasad, S.; Cui, M.; Zhang, Y.; Veraverbeke, S.

    2014-12-01

    Improved spatial representation of within-burn heterogeneity after wildfires is paramount to effective land management decisions and more accurate fire emissions estimates. In this work, we demonstrate feasibility and efficacy of airborne imaging spectroscopy (hyperspectral imagery) for quantifying wildfire burn severity, using kernel based image analysis techniques. Two different airborne hyperspectral datasets, acquired over the 2011 Canyon and 2013 Rim fire in California using the Airborne Visible InfraRed Imaging Spectrometer (AVIRIS) sensor, were used in this study. The Rim Fire, covering parts of the Yosemite National Park started on August 17, 2013, and was the third largest fire in California's history. Canyon Fire occurred in the Tehachapi mountains, and started on September 4, 2011. In addition to post-fire data for both fires, half of the Rim fire was also covered with pre-fire images. Fire severity was measured in the field using Geo Composite Burn Index (GeoCBI). The field data was utilized to train and validate our models, wherein the trained models, in conjunction with imaging spectroscopy data were used for GeoCBI estimation wide geographical regions. This work presents an approach for using remotely sensed imagery combined with GeoCBI field data to map fire scars based on a non-linear (kernel based) epsilon-Support Vector Regression (e-SVR), which was used to learn the relationship between spectra and GeoCBI in a kernel-induced feature space. Classification of healthy vegetation versus fire-affected areas based on morphological multi-attribute profiles was also studied. The availability of pre- and post-fire imaging spectroscopy data over the Rim Fire provided a unique opportunity to evaluate the performance of bi-temporal imaging spectroscopy for assessing post-fire effects. This type of data is currently constrained because of limited airborne acquisitions before a fire, but will become widespread with future spaceborne sensors such as those on the planned NASA HyspIRI mission.

  7. 30 CFR 57.4362 - Underground rescue and firefighting operations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4362 Underground rescue and firefighting operations. Following evacuation of a mine in a fire emergency, only persons wearing and trained...

  8. 30 CFR 57.4362 - Underground rescue and firefighting operations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4362 Underground rescue and firefighting operations. Following evacuation of a mine in a fire emergency, only persons wearing and trained...

  9. 30 CFR 57.4362 - Underground rescue and firefighting operations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4362 Underground rescue and firefighting operations. Following evacuation of a mine in a fire emergency, only persons wearing and trained...

  10. STS-72 Mission Specialist Koichi Wakata during ASCAN training

    NASA Image and Video Library

    1995-01-09

    S95-00353 (12-14 September 1992) --- Several 1992 astronaut candidates brush the sand and gravel off one another following one of several phases of parachute familiarization and survival training at Vance Air Force Base in Oklahoma. Recognizable in the picture are Wendy B. Lawrence, Michael E. Lopez-Alegria, Chris A. Hadfield, Winston E. Scott and Koichi Wakata. The trainees had just completed an exercise, which required their jumping off a box into a gravel pit, in order to familiarize them the proper way to meet the ground following an emergency parachute drop.

  11. Removal of Perfluorooctanoic Acid from Water Using Primitive, Conventional and Novel Carbonaceous Sorbent Materials

    DTIC Science & Technology

    Polyfluoroalkyl Substances ( PFAS ), like perfluorooctanoic acid, have been used for the last 50 years in a wide variety of industrial processes and...The Department of Defense (DoD) has used PFAS -based Aqueous Film Forming Foam (AFFF) at fire training facilities and aircraft hangars. These AFFFs have...contaminated approximately 600 sites classified as fire training facilities with PFAS (Huang, 2013). This study focused on testing the most likely

  12. Shock sensing dual mode warhead

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shamblen, M.; Walchak, M.T.; Richmond, L.

    1980-12-31

    A shock sensing dual mode warhead is provided for use against both soft and hard targets and is capable of sensing which type of target has been struck. The warhead comprises a casing made of a ductile material containing an explosive charge and a fuze assembly. The ductile warhead casing will mushroom upon striking a hard target while still confining the explosive. Proper ductility and confinement are necessary for fuze shock sensing. The fuze assembly contains a pair of parallel firing trains, one initiated only by dynamic pressure caused high impact deceleration and one initiated by low impact deceleration. Themore » firing train actuated by high impact deceleration senses dynamic pressure transmitted, during deformation of the warhead, through the explosive filler which is employed as a fuzing signature. The firing train actuated by low impact deceleration contains a pyrotechnic delay to allow penetration of soft targets.« less

  13. Cardiovascular health effects following exposure of human volunteers during fire extinction exercises.

    PubMed

    Andersen, Maria Helena Guerra; Saber, Anne Thoustrup; Pedersen, Peter Bøgh; Loft, Steffen; Hansen, Åse Marie; Koponen, Ismo Kalevi; Pedersen, Julie Elbæk; Ebbehøj, Niels; Nørskov, Eva-Carina; Clausen, Per Axel; Garde, Anne Helene; Vogel, Ulla; Møller, Peter

    2017-09-06

    Firefighters have increased risk of cardiovascular disease and of sudden death from coronary heart disease on duty while suppressing fires. This study investigated the effect of firefighting activities, using appropriate personal protective equipment (PPE), on biomarkers of cardiovascular effects in young conscripts training to become firefighters. Healthy conscripts (n = 43) who participated in a rescue educational course for firefighting were enrolled in the study. The exposure period consisted of a three-day training course where the conscripts participated in various firefighting exercises in a constructed firehouse and flashover container. The subjects were instructed to extinguish fires of either wood or wood with electrical cords and mattresses. The exposure to particulate matter (PM) was assessed at various locations and personal exposure was assessed by portable PM samplers and urinary excretion of 1-hydroxypyrene. Cardiovascular measurements included microvascular function and heart rate variability (HRV). The subjects were primarily exposed to PM in bystander positions, whereas self-contained breathing apparatus effectively abolished pulmonary exposure. Firefighting training was associated with elevated urinary excretion of 1-hydroxypyrene (105%, 95% CI: 52; 157%), increased body temperature, decreased microvascular function (-18%, 95% CI: -26; -9%) and altered HRV. There was no difference in cardiovascular measurements for the two types of fires. Observations from this fire extinction training show that PM exposure mainly occurs in situations where firefighters removed the self-contained breathing apparatus. Altered cardiovascular disease endpoints after the firefighting exercise period were most likely due to complex effects from PM exposure, physical exhaustion and increased core body temperature.

  14. 30 CFR 48.28 - Annual refresher training of miners; minimum courses of instruction; hours of instruction.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Retraining of Miners Working at Surface Mines and Surface Areas of Underground Mines § 48.28 Annual refresher...) Ground control; working in areas of highwalls, water hazards, pits, and spoil banks; illumination and... ground control plans in effect at the mine; procedures for working safely in areas of highwalls, water...

  15. Fire Safety Trianing in Health Care Institutions.

    ERIC Educational Resources Information Center

    American Hospital Association, Chicago, IL.

    The manual details the procedures to be followed in developing and implementing a fire safety plan. The three main steps are first, to organize; second, to set up a procedure and put it in writing; and third, to train and drill employees and staff. Step 1 involves organizing a safety committee, appointing a fire marshall, and seeking help from…

  16. Simulating Building Fires for Movies

    NASA Technical Reports Server (NTRS)

    Rodriguez, Ricardo C.; Johnson, Randall P.

    1987-01-01

    Fire scenes for cinematography staged at relatively low cost in method that combines several existing techniques. Nearly realistic scenes, suitable for firefighter training, produced with little specialized equipment. Sequences of scenes set up quickly and easily, without compromising safety because model not burned. Images of fire, steam, and smoke superimposed on image of building to simulate burning of building.

  17. Safety. Fire Service Certification Series. Unit FSCS-FF-2-80.

    ERIC Educational Resources Information Center

    Pribyl, Paul F.

    This training unit on safety is part of a 17-unit course package written to aid instructors in the development, teaching, and evaluation of fire fighters in the Wisconsin Fire Service Certification Series. The purpose stated for the 4-hour unit is to assist firefighters in understanding the hazards of their profession and some methods of reducing…

  18. Final Report on the Development of the Long Beach Fire Department Company Officer Orientation Program.

    ERIC Educational Resources Information Center

    Rupe, Marvin L.; And Others

    The Long Beach Fire Department (California), developed a program to foster and improve the development of future fire department managers who are promoted from within the department. A 10-day orientation program was developed. The competency-based program featured a mix of management-leadership training (the nature of leadership, personnel…

  19. Firefighting Trainer

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Firefighting trainees conduct fire control exercises using a prototype simulator known as the Emergency Management Computer Aided Training System (EMCAT). Developed by Marshall Space Flight Center (MFS) in response to a request from the Huntsville (AL) Fire Department, EMCAT enables a trainee to assume the role of fireground commander and make quick decisions on best use of his fire fighting personnel and equipment.

  20. KSC00pp1439

    NASA Image and Video Library

    2000-09-14

    KENNEDY SPACE CENTER, FLA. -- During training exercises at Cape Canaveral Air Force Station Pad 30, firefighters with the Fire and Emergency Services at the Naval Station Mayport, Fla., turn their hoses toward the fire on the simulated aircraft.

  1. KSC-00pp1439

    NASA Image and Video Library

    2000-09-14

    KENNEDY SPACE CENTER, FLA. -- During training exercises at Cape Canaveral Air Force Station Pad 30, firefighters with the Fire and Emergency Services at the Naval Station Mayport, Fla., turn their hoses toward the fire on the simulated aircraft.

  2. The Chronotron: A Neuron That Learns to Fire Temporally Precise Spike Patterns

    PubMed Central

    Florian, Răzvan V.

    2012-01-01

    In many cases, neurons process information carried by the precise timings of spikes. Here we show how neurons can learn to generate specific temporally precise output spikes in response to input patterns of spikes having precise timings, thus processing and memorizing information that is entirely temporally coded, both as input and as output. We introduce two new supervised learning rules for spiking neurons with temporal coding of information (chronotrons), one that provides high memory capacity (E-learning), and one that has a higher biological plausibility (I-learning). With I-learning, the neuron learns to fire the target spike trains through synaptic changes that are proportional to the synaptic currents at the timings of real and target output spikes. We study these learning rules in computer simulations where we train integrate-and-fire neurons. Both learning rules allow neurons to fire at the desired timings, with sub-millisecond precision. We show how chronotrons can learn to classify their inputs, by firing identical, temporally precise spike trains for different inputs belonging to the same class. When the input is noisy, the classification also leads to noise reduction. We compute lower bounds for the memory capacity of chronotrons and explore the influence of various parameters on chronotrons' performance. The chronotrons can model neurons that encode information in the time of the first spike relative to the onset of salient stimuli or neurons in oscillatory networks that encode information in the phases of spikes relative to the background oscillation. Our results show that firing one spike per cycle optimizes memory capacity in neurons encoding information in the phase of firing relative to a background rhythm. PMID:22879876

  3. A WSN-Based Tool for Urban and Industrial Fire-Fighting

    PubMed Central

    De San Bernabe Clemente, Alberto; Dios, José Ramiro Martínez-de; Baturone, Aníbal Ollero

    2012-01-01

    This paper describes a WSN tool to increase safety in urban and industrial fire-fighting activities. Unlike most approaches, we assume that there is no preexisting WSN in the building, which involves interesting advantages but imposes some constraints. The system integrates the following functionalities: fire monitoring, firefighter monitoring and dynamic escape path guiding. It also includes a robust localization method that employs RSSI-range models dynamically trained to cope with the peculiarities of the environment. The training and application stages of the method are applied simultaneously, resulting in significant adaptability. Besides simulations and laboratory tests, a prototype of the proposed system has been validated in close-to-operational conditions. PMID:23202198

  4. Including long-range dependence in integrate-and-fire models of the high interspike-interval variability of cortical neurons.

    PubMed

    Jackson, B Scott

    2004-10-01

    Many different types of integrate-and-fire models have been designed in order to explain how it is possible for a cortical neuron to integrate over many independent inputs while still producing highly variable spike trains. Within this context, the variability of spike trains has been almost exclusively measured using the coefficient of variation of interspike intervals. However, another important statistical property that has been found in cortical spike trains and is closely associated with their high firing variability is long-range dependence. We investigate the conditions, if any, under which such models produce output spike trains with both interspike-interval variability and long-range dependence similar to those that have previously been measured from actual cortical neurons. We first show analytically that a large class of high-variability integrate-and-fire models is incapable of producing such outputs based on the fact that their output spike trains are always mathematically equivalent to renewal processes. This class of models subsumes a majority of previously published models, including those that use excitation-inhibition balance, correlated inputs, partial reset, or nonlinear leakage to produce outputs with high variability. Next, we study integrate-and-fire models that have (nonPoissonian) renewal point process inputs instead of the Poisson point process inputs used in the preceding class of models. The confluence of our analytical and simulation results implies that the renewal-input model is capable of producing high variability and long-range dependence comparable to that seen in spike trains recorded from cortical neurons, but only if the interspike intervals of the inputs have infinite variance, a physiologically unrealistic condition. Finally, we suggest a new integrate-and-fire model that does not suffer any of the previously mentioned shortcomings. By analyzing simulation results for this model, we show that it is capable of producing output spike trains with interspike-interval variability and long-range dependence that match empirical data from cortical spike trains. This model is similar to the other models in this study, except that its inputs are fractional-gaussian-noise-driven Poisson processes rather than renewal point processes. In addition to this model's success in producing realistic output spike trains, its inputs have long-range dependence similar to that found in most subcortical neurons in sensory pathways, including the inputs to cortex. Analysis of output spike trains from simulations of this model also shows that a tight balance between the amounts of excitation and inhibition at the inputs to cortical neurons is not necessary for high interspike-interval variability at their outputs. Furthermore, in our analysis of this model, we show that the superposition of many fractional-gaussian-noise-driven Poisson processes does not approximate a Poisson process, which challenges the common assumption that the total effect of a large number of inputs on a neuron is well represented by a Poisson process.

  5. Automated Wildfire Detection Through Artificial Neural Networks

    NASA Technical Reports Server (NTRS)

    Miller, Jerry; Borne, Kirk; Thomas, Brian; Huang, Zhenping; Chi, Yuechen

    2005-01-01

    Wildfires have a profound impact upon the biosphere and our society in general. They cause loss of life, destruction of personal property and natural resources and alter the chemistry of the atmosphere. In response to the concern over the consequences of wildland fire and to support the fire management community, the National Oceanic and Atmospheric Administration (NOAA), National Environmental Satellite, Data and Information Service (NESDIS) located in Camp Springs, Maryland gradually developed an operational system to routinely monitor wildland fire by satellite observations. The Hazard Mapping System, as it is known today, allows a team of trained fire analysts to examine and integrate, on a daily basis, remote sensing data from Geostationary Operational Environmental Satellite (GOES), Advanced Very High Resolution Radiometer (AVHRR) and Moderate Resolution Imaging Spectroradiometer (MODIS) satellite sensors and generate a 24 hour fire product for the conterminous United States. Although assisted by automated fire detection algorithms, N O M has not been able to eliminate the human element from their fire detection procedures. As a consequence, the manually intensive effort has prevented NOAA from transitioning to a global fire product as urged particularly by climate modelers. NASA at Goddard Space Flight Center in Greenbelt, Maryland is helping N O M more fully automate the Hazard Mapping System by training neural networks to mimic the decision-making process of the frre analyst team as well as the automated algorithms.

  6. Is There Any Scientific Basis of Hawan to be used in Epilepsy-Prevention/Cure?

    PubMed Central

    Bansal, Parveen; Kaur, Ramandeep; Gupta, Vikas; Kumar, Sanjiv; Kaur, RamanPreet

    2015-01-01

    Epilepsy is a neuropsychiatric disorder associated with religiosity and spirituality. Nasal drug delivery systems are the best for diseases related to brain. In older times RishiMuni, ancient scholars and physicians used to recommend Hawan for mental peace and well being. Gayatri Mantra also tells that sughandhim (aroma, fragrance) puushtivardhanam (gives rise to good health). Om triambkum yajamahe, sughandhim puushtivardhanam, urvarukmev vandhanaat, mrityu mokshay mamritaat! Hawan is a scientific experiment in which special herbs (Hawan Samagri) are offered in the fire of medicinal woods ignited in a specially designed fire pit called agnikuñda. Hawan seems to be designed by the ancient scholars to fight with the diseases of the brain. Our metadata analysis demonstrates that the components of Hawan are having a number of volatile oils that are specifically useful for epilepsy through one or the other mechanism of action. Due to high temperature of fire the vapors of these oils enter into the central nervous system through nasal route. The routine of performing Hawan might keep the threshold value of the therapeutic components in the body and help in preventing epilepsy. In the present manuscript authors have tried to highlight and integrate the modern and ancient concepts for treatment and prevention of epilepsy. PMID:26819935

  7. The Application for a Prediction of the Coal Spontaneous Ignition - Predisam

    NASA Astrophysics Data System (ADS)

    Moni, Vlastimil; Klouda, Petr; Blata, Jan; Helebrant, František

    2017-06-01

    The article follows the research of the project number TA01020351 called "The research of possibilities when predicting steam origin and consequent spontaneous ignition of brown coal fuels" which was researched with the support of the Technological Agency in the Czech Republic in 2011-2014 in the connection with a realized technical research. Therefore, it gives a summary information about the evaluation of the risk degree for the origin of spontaneous ignitions of the brown coal. The presented way of evaluation is based on a numeric expression of a value for MHU criteria - the point load of particular indicators is added together with other results gained from this research project. Then, more information is taken from companies running the dumps of brown coal products - both for suppliers (mining companies) and big consumers (power engineering). The complex knowledge about prediction of the origin of the spontaneous ignition enables to make an early response to eliminate a threat of mining fire in open pit mines or on the dumps of coal products. Consequently, it reduces the risk of fire and breakdowns of transportation means DPD, heavy machines and preparation plants. The working injuries are reduced as well - burns by coal in fire or inhalation of gas products from imperfect combustion.

  8. Support for Astronaut's View of Mexican/ Central American Fires and on-Line Earth Observations Training Manual

    NASA Technical Reports Server (NTRS)

    Kaminski, Charles F., Jr.

    1999-01-01

    A small project to compile remote sensing and in-site data to review the processes leading to the May 1998 Mexican/Central American fires was undertaken. A web page based on this project was assembled. The second project initiated involved an interactive and on-line program that will replace the paper version of the Earth Observations Preflight Training Manual. Technical support was provided to Prof. Marvin Glasser as needed.

  9. Integral Color Anodizing of Aluminum Alloy 7075-T6 Upper Receivers of the M16A1 Rifle

    DTIC Science & Technology

    1981-06-01

    and control upper receivers were carried, fired, and maintained by soldiers in the field undergoing basic and advanced Infantry training and by other...soldiers undergoing Ranger training . The test and control items were subjected to typical field usage conditions involving rough handhng, firing...ICA hardcoat treatment will provide a longer inservice life for the M16A1 rifle receivers than will the low- temperature hardcoat process. 12

  10. Measuring Synaptic Vesicle Endocytosis in Cultured Hippocampal Neurons.

    PubMed

    Villarreal, Seth; Lee, Sung Hoon; Wu, Ling-Gang

    2017-09-04

    During endocytosis, fused synaptic vesicles are retrieved at nerve terminals, allowing for vesicle recycling and thus the maintenance of synaptic transmission during repetitive nerve firing. Impaired endocytosis in pathological conditions leads to decreases in synaptic strength and brain functions. Here, we describe methods used to measure synaptic vesicle endocytosis at the mammalian hippocampal synapse in neuronal culture. We monitored synaptic vesicle protein endocytosis by fusing a synaptic vesicular membrane protein, including synaptophysin and VAMP2/synaptobrevin, at the vesicular lumenal side, with pHluorin, a pH-sensitive green fluorescent protein that increases its fluorescence intensity as the pH increases. During exocytosis, vesicular lumen pH increases, whereas during endocytosis vesicular lumen pH is re-acidified. Thus, an increase of pHluorin fluorescence intensity indicates fusion, whereas a decrease indicates endocytosis of the labelled synaptic vesicle protein. In addition to using the pHluorin imaging method to record endocytosis, we monitored vesicular membrane endocytosis by electron microscopy (EM) measurements of Horseradish peroxidase (HRP) uptake by vesicles. Finally, we monitored the formation of nerve terminal membrane pits at various times after high potassium-induced depolarization. The time course of HRP uptake and membrane pit formation indicates the time course of endocytosis.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keller, David Charles

    In 2014, baseline storm water monitoring samples for Potrillo Canyon Sample Management Area at Los Alamos National Laboratory (LANL) exceeded the National Pollutant Discharge Elimination System Individual Permit No. NM0030759 target action level (TAL) of 15 picocuries per liter (pCi/L) for gross-alpha radioactivity (393 pCi/L) and a TAL of 30 pCi/L for radium-226 and radium-228 (95.9 pCi/L). Consequently, erosion control measures within the management area are proposed to minimize sediment migration, a corrective action under the permit that is a requirement of the New Mexico Environment Department consent decree and a good management practice to limit off-site sediment migration. Themore » area proposed for erosion controls consists of portions of Technical Area 36 that were used as firing sites primarily involving high explosives (HE) and metal (e.g., depleted uranium, lead, copper, aluminum, and steel), small-explosives experiments and burn pits (burn pits were used for burning and disposal of test debris). In addition, underground explosive tests at an approximate depth of 100 feet were also conducted. These watershed-based storm water controls will focus on addressing erosion occurring within the floodplain through mitigating and reducing both current and future channelization and head cutting.« less

  12. Special report. Revising your fire safety plans.

    PubMed

    1993-12-01

    Every hospital has a fire safety plan, although some fail to update their plans when circumstances change, such as when the facility is refurbished or new fire protection equipment is added, or when new wings bring in additional patients and staff. Others may fail to develop new education programs to heighten staff awareness of what is expected of them during a fire and to train employees to meet those expectations. In this report, we'll examine the new fire safety plans at two Massachusetts hospitals and the revisions they made to address these issues. We'll offer suggestions for effectively evaluating and revising your own fire safety plans.

  13. Water Supply. Fire Service Certification Series. Unit FSCS-FF-9-80.

    ERIC Educational Resources Information Center

    Pribyl, Paul F.

    This training unit on water supply is part of a 17-unit course package written to aid instructors in the development, teaching, and evaluation of fire fighters in the Wisconsin Fire Service Certification Series. The purpose stated for the 4-hour unit is to assist the firefighter in the proper use of water supplies and the understanding of the…

  14. Fire Play: ICCARUS--Intelligent Command and Control, Acquisition and Review Using Simulation

    ERIC Educational Resources Information Center

    Powell, James; Wright, Theo; Newland, Paul; Creed, Chris; Logan, Brian

    2008-01-01

    Is it possible to educate a fire officer to deal intelligently with the command and control of a major fire event he will never have experienced? The authors of this paper believe there is, and present here just one solution to this training challenge. It involves the development of an intelligent simulation based upon computer managed interactive…

  15. Boosting fire drill participation in hospital settings.

    PubMed

    Prosper, Darryl

    2015-01-01

    In a health system with over 100 sites in a geographically dispersed region, boosting fire drill participation to meet government requirements, according to the author, is a constant effort, both to achieve and to maintain. In this article, he describes a comprehensive approach that entails engagement of executive, site committees and local fire authorities, as well as comprehensive training and awareness campaigns.

  16. 29 CFR 1915.508 - Training.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... responsibilities at all times; (2) Keep written standard operating procedures that address anticipated emergency... the employer's standard operating procedures; (5) Train new fire response employees before they engage in emergency operations; (6) At least quarterly, provide training on the written operating procedures...

  17. 29 CFR 1915.508 - Training.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... responsibilities at all times; (2) Keep written standard operating procedures that address anticipated emergency... the employer's standard operating procedures; (5) Train new fire response employees before they engage in emergency operations; (6) At least quarterly, provide training on the written operating procedures...

  18. 29 CFR 1915.508 - Training.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... responsibilities at all times; (2) Keep written standard operating procedures that address anticipated emergency... the employer's standard operating procedures; (5) Train new fire response employees before they engage in emergency operations; (6) At least quarterly, provide training on the written operating procedures...

  19. 29 CFR 1915.508 - Training.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... responsibilities at all times; (2) Keep written standard operating procedures that address anticipated emergency... the employer's standard operating procedures; (5) Train new fire response employees before they engage in emergency operations; (6) At least quarterly, provide training on the written operating procedures...

  20. 29 CFR 1915.508 - Training.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... responsibilities at all times; (2) Keep written standard operating procedures that address anticipated emergency... the employer's standard operating procedures; (5) Train new fire response employees before they engage in emergency operations; (6) At least quarterly, provide training on the written operating procedures...

  1. Evidence of a Transition from Perceptual to Category Induction in 3- to 9-Year-Old Children

    ERIC Educational Resources Information Center

    Badger, Julia R.; Shapiro, Laura R.

    2012-01-01

    We examined whether inductive reasoning development is better characterized by accounts assuming an early category bias versus an early perceptual bias. We trained 264 children aged 3 to 9 years to categorize novel insects using a rule that directly pitted category membership against appearance. This was followed by an induction task with…

  2. Landmark vs. Geometry Learning: Explaining Female Rats' Selective Preference for a Landmark

    ERIC Educational Resources Information Center

    Torres, Marta N.; Rodríguez, Clara A.; Chamizo, V. D.; Mackintosh, N. J.

    2014-01-01

    Rats were trained in a triangular-shaped pool to find a hidden platform, whose location was defined in terms of two sources of information, a landmark outside the pool and a particular corner of the pool. Subsequent test trials without the platform pitted these two sources of information against one another. In Experiment 1 this test revealed a…

  3. Naval Training Equipment Center Index of Technical Reports,

    DTIC Science & Technology

    1982-09-01

    741 RECOMMENDED PROCEDURES AND TRAINING NAVAL TRAINING AIDS. tAMPHIBIOUS OPERATIONS PROCEDURES AND RESEARCH PLANNING AD- 642 590 TRAINING DEVICES FOR...PROCEDURES AND RESEARCH PLANNING OBSERVATION AND FIRE CONTROL WITH FOR ANTI-AIR WARFARE TRAINING SPECIFIC REFERENCE TO THE TRAINING *AMPUTEES PROGRAM...619 AD- 707 757 NAVAL PERSONNEL *COMMUNICATION SATELLITES PROCEDURES AND RESEARCH PLANNING *COMBUSTION PRODUCTS Computer Managed Instruction by FOR

  4. Fire in operating theatres: DaSH-ing to the rescue.

    PubMed

    Wilson, Liam; Farooq, Omer

    2018-01-01

    Operating theatres are dynamic environments that require multi professional team interactions. Effective team working is essential for efficient delivery of safe patient care. A fire in the operating theatre is a rare but potentially life threatening event for both patients and staff. A rapid and cohesive response from theatre and allied staff including porters, fire safety officer etc is paramount. We delivered a training session that utilised in situ simulation (simulation in workplace). After conducting needs analysis, learning objectives were agreed. After thorough planning, the date and location of the training session were identified. Contingency plans were put in place to ensure that patient care was not compromised at any point. To ensure success, checklists for faculty were devised and adhered to. A medium fidelity manikin with live monitoring was used. The first part of the scenario involved management of a surgical emergency by theatre staff. The second part involved management of a fire in the operating theatre while an emergency procedure was being undertaken. To achieve maximum learning potential, debriefing was provided immediately after each part of the scenario. A fire safety officer was present as a content expert. Latent errors (hidden errors in the workplace, staff knowledge etc) were identified. Malfunctioning of theatre floor windows and staff unawareness about the location of an evacuation site were some of the identified latent errors. Thorough feedback to address these issues was provided to the participants on the day. A detailed report of the training session was given to the relevant departments. This resulted in the equipment faults being rectified. The training session was a very positive experience and helped not only in improving participants' knowledge, behaviour and confidence but also it made system and environment better equipped.

  5. KSC-2011-6637

    NASA Image and Video Library

    2011-08-31

    CAPE CANAVERAL, Fla. -- NASA Fire Rescue personnel assist a volunteer portraying an injured Huey II helicopter crew member participating in the aviation safety exercise during Emergency Response Safety Training at the Shuttle Landing Facility, Runway 33, at NASA’s Kennedy Space Center in Florida. The simulated helicopter mishap exercise was conducted to evaluate emergency response and mishap investigations of aircraft at Kennedy. Participants included Air Rescue Fire Fighters, Flight Operations, Disaster Preparedness, Security, and Safety. NASA mandates simulated aviation safety training take place every two years. Photo credit: NASA/Kim Shiflett

  6. KSC-2011-6644

    NASA Image and Video Library

    2011-08-31

    CAPE CANAVERAL, Fla. -- An ambulance and several NASA Fire Rescue Services vehicles arrive to assist a Huey II helicopter participating in the aviation safety exercise during Emergency Response Safety Training at the Shuttle Landing Facility, Runway 33, at NASA’s Kennedy Space Center in Florida. The simulated helicopter mishap exercise was conducted to evaluate emergency response and mishap investigations of aircraft at Kennedy. Participants included Air Rescue Fire Fighters, Flight Operations, Disaster Preparedness, Security, and Safety. NASA mandates simulated aviation safety training take place every two years. Photo credit: NASA/Kim Shiflett

  7. KSC-2011-6640

    NASA Image and Video Library

    2011-08-31

    CAPE CANAVERAL, Fla. -- NASA Fire Rescue personnel assist volunteers portraying injured Huey II helicopter crew members participating in the aviation safety exercise during Emergency Response Safety Training at the Shuttle Landing Facility, Runway 33, at NASA’s Kennedy Space Center in Florida. The simulated helicopter mishap exercise was conducted to evaluate emergency response and mishap investigations of aircraft at Kennedy. Participants included Air Rescue Fire Fighters, Flight Operations, Disaster Preparedness, Security, and Safety. NASA mandates simulated aviation safety training take place every two years. Photo credit: NASA/Kim Shiflett

  8. KSC-2011-6639

    NASA Image and Video Library

    2011-08-31

    CAPE CANAVERAL, Fla. -- NASA Fire Rescue personnel assist volunteers portraying injured Huey II helicopter crew members participating in the aviation safety exercise during Emergency Response Safety Training at the Shuttle Landing Facility, Runway 33, at NASA’s Kennedy Space Center in Florida. The simulated helicopter mishap exercise was conducted to evaluate emergency response and mishap investigations of aircraft at Kennedy. Participants included Air Rescue Fire Fighters, Flight Operations, Disaster Preparedness, Security, and Safety. NASA mandates simulated aviation safety training take place every two years. Photo credit: NASA/Kim Shiflett

  9. KSC-2011-6634

    NASA Image and Video Library

    2011-08-31

    CAPE CANAVERAL, Fla. -- A NASA Fire Rescue Services vehicle and a Huey II helicopter support the aviation safety exercise during Emergency Response Safety Training at the Shuttle Landing Facility, Runway 33, at NASA’s Kennedy Space Center in Florida. The simulated helicopter mishap exercise was conducted to evaluate emergency response and mishap investigations of aircraft at Kennedy. Participants included Air Rescue Fire Fighters, Flight Operations, Disaster Preparedness, Security, and Safety. NASA mandates simulated aviation safety training take place every two years. Photo credit: NASA/Kim Shiflett

  10. KSC-2011-6638

    NASA Image and Video Library

    2011-08-31

    CAPE CANAVERAL, Fla. -- NASA Fire Rescue personnel assist volunteers portraying injured Huey II helicopter crew members participating in the aviation safety exercise during Emergency Response Safety Training at the Shuttle Landing Facility, Runway 33, at NASA’s Kennedy Space Center in Florida. The simulated helicopter mishap exercise was conducted to evaluate emergency response and mishap investigations of aircraft at Kennedy. Participants included Air Rescue Fire Fighters, Flight Operations, Disaster Preparedness, Security, and Safety. NASA mandates simulated aviation safety training take place every two years. Photo credit: NASA/Kim Shiflett

  11. KSC-2011-6636

    NASA Image and Video Library

    2011-08-31

    CAPE CANAVERAL, Fla. -- A NASA Fire Rescue Services vehicle, ambulance and Huey II helicopter take part in the aviation safety exercise during Emergency Response Safety Training at the Shuttle Landing Facility, Runway 33, at NASA’s Kennedy Space Center in Florida. The simulated helicopter mishap exercise was conducted to evaluate emergency response and mishap investigations of aircraft at Kennedy. Participants included Air Rescue Fire Fighters, Flight Operations, Disaster Preparedness, Security, and Safety. NASA mandates simulated aviation safety training take place every two years. Photo credit: NASA/Kim Shiflett

  12. KSC-2011-6641

    NASA Image and Video Library

    2011-08-31

    CAPE CANAVERAL, Fla. -- NASA Fire Rescue personnel assist volunteers portraying injured Huey II helicopter crew members participating in the aviation safety exercise during Emergency Response Safety Training at the Shuttle Landing Facility, Runway 33, at NASA’s Kennedy Space Center in Florida. The simulated helicopter mishap exercise was conducted to evaluate emergency response and mishap investigations of aircraft at Kennedy. Participants included Air Rescue Fire Fighters, Flight Operations, Disaster Preparedness, Security, and Safety. NASA mandates simulated aviation safety training take place every two years. Photo credit: NASA/Kim Shiflett

  13. KSC-2011-6645

    NASA Image and Video Library

    2011-08-31

    CAPE CANAVERAL, Fla. -- Volunteers portraying injured Huey II helicopter crew members are assisted by NASA Fire Rescue personnel in support of the aviation safety exercise during Emergency Response Safety Training at the Shuttle Landing Facility, Runway 33, at NASA’s Kennedy Space Center in Florida. The simulated helicopter mishap exercise was conducted to evaluate emergency response and mishap investigations of aircraft at Kennedy. Participants included Air Rescue Fire Fighters, Flight Operations, Disaster Preparedness, Security, and Safety. NASA mandates simulated aviation safety training take place every two years. Photo credit: NASA/Kim Shiflett

  14. The Development of a Rapid Train-Up Package and Platoon-Level Scenarios for Armor Training in the Army National Guard

    DTIC Science & Technology

    1991-11-01

    equipped with T-72 tanks and BMPs. He has extensive indirect fire and electronic warfare assets. No chemicals have been used in the past 48 hours...BMPs. He has an extensive electronic warfare and indirect fire capability. Chemical weapons have not been used in the past 24 hours. Indications are...and Campshure (1989) observed that some battlefield activities are not simulated at all on SIMNET (e.g., dismounting, employing chemical alarms

  15. Major International R and D Ranges and Test Facilities. Summary of Capabilities

    DTIC Science & Technology

    1990-01-01

    with a maximum impulse of firing of large numbers of rounds by a weapon in order to 1500 G and a maximum test item weight of 200 pounds. produce...millimetres may be fired safely, using test item weight of 1,000 pounds. training practice or training practice tracer ammunition. The :ange butts consist of...predictions of coherent sound propagation loss in the ocean. This information is useful in estimating the performance of low-frequency passive sonars

  16. Occupational exposure to airborne lead in Brazilian police officers.

    PubMed

    Rocha, Ernesto Díaz; Sarkis, Jorge E Souza; Carvalho, Maria de Fátima H; Santos, Gerson Vechio Dos; Canesso, Claudemir

    2014-07-01

    Shooting with lead-containing ammunition in indoor firing ranges is a known source of lead exposure in adults. Police officers may be at risk of lead intoxication when regular training shooting exercises are yearly mandatory to law enforcement officers. Effects on health must be documented, even when low-level elemental (inorganic) lead exposure is detected. Forty police officers (nineteen cadets and twenty-one instructors) responded to a questionnaire about health, shooting habits, and potential lead exposure before a training curse. Blood samples were collected and analyzed for blood lead level (BLL) before and after a three days training curse. The mean BLL for the instructors' group was 5.5 μg/dL ± 0.6. The mean BLL for the cadets' group before the training was 3.3 μg/dL ± 0.15 and after the training the main BLL was 18.2 μg/d L± 1.5. Samples were analyzed by Inductively Coupled Plasma Mass Spectrometer (ICP-MS). All the participants in the training curse had significantly increased BLL (mean increment about 15 μg/dL) after the three days indoor shooting season. In conclusion, occupational lead exposure in indoor firing ranges is a source of lead exposure in Brazilian police officers, and appears to be a health risk, especially when heavy weapons with lead-containing ammunition are used in indoor environments during the firing training seasons. Copyright © 2013 Elsevier GmbH. All rights reserved.

  17. Study of Training Device Needs for Meeting Basic Officer Tactics Training Requirements. Volume I of II. Final Report.

    ERIC Educational Resources Information Center

    Hammell, Thomas J.; And Others

    A study was conducted to determine the appropriate training objectives for fire control personnel aboard nuclear submarines, to identify specific requirements for training materials to accomplish these objectives, and to provide functional descriptions of recommended training devices. A task analysis was conducted to determine the skill and…

  18. KSC-04pd1656

    NASA Image and Video Library

    2004-08-05

    KENNEDY SPACE CENTER, FLA. - At the ribbon cutting for the Enhanced Firing Range on Schwartz Rd. at Kennedy Space Center, Center Director Jim Kennedy practices firing on the new range. NASA’s Federal Law Enforcement Training Academy’s firing range has been upgraded to include a “rifle-grade” shoot house, a portable, tactical “shoot-back” trailer for cover and concealment drills, automated running targets and a new classroom facility. They are added to the existing three firearms ranges, “pistol-grade” shoot house, obstacle course and rappel tower. NASA’s Security Management and Safeguards Office funded the enhancements in order to improve ability to train the KSC security force and to support local, state and federal law enforcement agencies in Homeland Security.

  19. Integrated Launch Operations Applications Remote Display Developer

    NASA Technical Reports Server (NTRS)

    Flemming, Cedric M., II

    2014-01-01

    This internship provides the opportunity to support the creation and use of Firing Room Displays and Firing Room Applications that use an abstraction layer called the Application Control Language (ACL). Required training included video watching, reading assignments, face-to-face instruction and job shadowing other Firing Room software developers as they completed their daily duties. During the training period various computer and access rights needed for creating the applications were obtained. The specific ground subsystems supported are the Cryogenics Subsystems, Liquid Hydrogen (LH2) and Liquid Oxygen (LO2). The cryogenics team is given the task of finding the best way to handle these very volatile liquids that are used to fuel the Space Launch System (SLS) and the Orion flight vehicles safely.

  20. Superfund record of decision (EPA Region 10): Mountain Home Air Force Base, Site 8, Fire Training Area 8, Operable Unit 4, Elmore County, Mountain Home, ID. (First remedial action), June 1992. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-06-16

    The 7-acre Mountain Home Air Force Base (AFB) site was a fire department training area located in Mountain Home, Elmore County, Idaho. From 1962 to 1975, the Mountain Home Air Force Base used the site for fire department training exercises. Each exercise began by saturating the bermed training area with water, followed directly by applying 250 to 500 gallons of fuel. The flames were extinguished with Aqueous Film Forming Foam (AFFF), or prior to 1972, with a water-based protein foam. The training session was completed with a post-exercise ignition of the residual fuel in a bermed area. The USAF investigationsmore » identified solvents and petroleum, oil, lubricant (POL) wastes in the soil. Under the Installation Restoration Program (IRP), the USAF conducted a record search, drilling, and sampling of soil borings to bedrock, the installation of monitoring wells, and hand auger samples. The ROD provided a final remedy for onsite soil as OU4. Because contaminants were found at such low concentrations, the soil was covered by crushed asphalt and has little potential to impact ecological receptors. The soil posed low risks for humans at the site and no remediation was necessary.« less

  1. GIS tools, courses, and learning pathways offered by The National Interagency Fuels, Fire, and Vegetation Technology Transfer (NIFTT)

    Treesearch

    Heather Heward; Kathy H. Schon

    2009-01-01

    As technology continues to evolve in the area of fuel and wildland fire management so does the need to have effective tools and training on these technologies. The National Interagency Fuels Coordination Group has chartered a team of professionals to coordinate, develop, and transfer consistent, efficient, science-based fuel and fire ecology assessment GIS tools and...

  2. Indianapolis Fire Department EMS Communications Center tracking truck, train HAZMAT cargoes with "Operation Respond" software

    DOT National Transportation Integrated Search

    1997-06-05

    When an accident involving the transportation of potentially dangerous materials occurs, local emergency response officials need accurate information about the material as quickly as possible. Using software donated to the Indianapolis Fire Departmen...

  3. A field demonstration of the microbial treatment of sour produced water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sublette, K.L.; Morse, D.; Raterman, K.

    1995-12-31

    The potential for detoxification and deodorization of sulfide-laden water (sour water) by microbial treatment was evaluated at a petroleum production site under field conditions. A sulfide-tolerant strain of the chemautotroph and facultative anaerobe, Thiobacillus denitrificans, was introduced into an oil-skimming pit of the Amoco Production Company LACT 10 Unit of the Salt Creek Field, Wyoming. Field-produced water enters this pit from the oil/water separation treatment train at an average flowrate of 5,000 bbl/D (795 m{sup 3}/D) with a potential maximum of 98,000 bbl/D (15,580 m{sup 3}/D). Water conditions at the pit inlet are 4,800 mg/l TDS, 100 mg/l sulfide, pHmore » 7.8, and 107{degrees}F. To this water an aqueous solution of ammonium nitrate and diphosphorous pentoxide was added to provide required nutrients for the bacteria. The first 20% of the pit was aerated to a maximum depth of 5 ft (1.5 m) to facilitate the aerobic oxidation of sulfide. No provisions for pH control or biomass recovery and recycle were made. Pilot operations were initiated in October 1992 with the inoculation of the 19,000 bbl (3,020 m{sup 3}) pit with 40 lb (18.1 kg) of dry weight biomass. After a brief acclimation period, a nearly constant mass flux of 175 lb/D (80 kg/D) sulfide was established to the pit. Bio-oxidation of sulfide to elemental sulfur and sulfate was immediate and complete. Subsequent pilot operations focused upon process optimization and process sensitivity to system upsets. The process appeared most sensitive to large variations in sulfide loading due to maximum water discharge events. However, recoveries from such events could be accomplished within hours. This paper details all pertinent aspects of pilot operation, performance, and economics. Based on this body of evidence, it is suggested that the oxidation of inorganic sulfides by T denitrificans represents a viable concept for the treatment of sour water coproduced with oil and gas.« less

  4. Discovering Cohorts of Pregnant Women From Social Media for Safety Surveillance and Analysis.

    PubMed

    Sarker, Abeed; Chandrashekar, Pramod; Magge, Arjun; Cai, Haitao; Klein, Ari; Gonzalez, Graciela

    2017-10-30

    Pregnancy exposure registries are the primary sources of information about the safety of maternal usage of medications during pregnancy. Such registries enroll pregnant women in a voluntary fashion early on in pregnancy and follow them until the end of pregnancy or longer to systematically collect information regarding specific pregnancy outcomes. Although the model of pregnancy registries has distinct advantages over other study designs, they are faced with numerous challenges and limitations such as low enrollment rate, high cost, and selection bias. The primary objectives of this study were to systematically assess whether social media (Twitter) can be used to discover cohorts of pregnant women and to develop and deploy a natural language processing and machine learning pipeline for the automatic collection of cohort information. In addition, we also attempted to ascertain, in a preliminary fashion, what types of longitudinal information may potentially be mined from the collected cohort information. Our discovery of pregnant women relies on detecting pregnancy-indicating tweets (PITs), which are statements posted by pregnant women regarding their pregnancies. We used a set of 14 patterns to first detect potential PITs. We manually annotated a sample of 14,156 of the retrieved user posts to distinguish real PITs from false positives and trained a supervised classification system to detect real PITs. We optimized the classification system via cross validation, with features and settings targeted toward optimizing precision for the positive class. For users identified to be posting real PITs via automatic classification, our pipeline collected all their available past and future posts from which other information (eg, medication usage and fetal outcomes) may be mined. Our rule-based PIT detection approach retrieved over 200,000 posts over a period of 18 months. Manual annotation agreement for three annotators was very high at kappa (κ)=.79. On a blind test set, the implemented classifier obtained an overall F 1 score of 0.84 (0.88 for the pregnancy class and 0.68 for the nonpregnancy class). Precision for the pregnancy class was 0.93, and recall was 0.84. Feature analysis showed that the combination of dense and sparse vectors for classification achieved optimal performance. Employing the trained classifier resulted in the identification of 71,954 users from the collected posts. Over 250 million posts were retrieved for these users, which provided a multitude of longitudinal information about them. Social media sources such as Twitter can be used to identify large cohorts of pregnant women and to gather longitudinal information via automated processing of their postings. Considering the many drawbacks and limitations of pregnancy registries, social media mining may provide beneficial complementary information. Although the cohort sizes identified over social media are large, future research will have to assess the completeness of the information available through them. ©Abeed Sarker, Pramod Chandrashekar, Arjun Magge, Haitao Cai, Ari Klein, Graciela Gonzalez. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 30.10.2017.

  5. House fire injury prevention update. Part II. A review of the effectiveness of preventive interventions

    PubMed Central

    Warda, L.; Tenenbein, M.; Moffatt, M.

    1999-01-01

    Objective—To evaluate and summarize the house fire injury prevention literature. Methods—MEDLINE (1983 to March 1997) was searched by keyword: fire, burn, etiology, cause, prevention, epidemiology, and smoke detector/alarm. ERIC (1966 to March 1997) and PSYCLIT (1974 to June 1997) were searched by keyword: as above, and safety, skills, education, and training. Other sources included references of retrieved publications, review articles, and books; Injury Prevention hand search; government documents; and internet sources. Sources relevant to residential fire injury prevention were selected, evaluated, and summarized. Results—Forty three publications were selected for review, including seven randomized controlled trials, nine quasiexperiments, two natural experiments, 21 prospective cohort studies, two cross sectional surveys, one case report, and one program evaluation. These studies examined the following types of interventions: school (9), preschool (1), and community based educational programs (5); fire response training programs for children (7), blind adolescents (2), and mentally retarded adults (5) and children (1); office based counseling (4); home inspection programs (3); smoke detector giveaway campaigns (5); and smoke detector legislation (1). Conclusions—This review of house fire prevention interventions underscores the importance of program evaluation. There is a need for more rigorous evaluation of educational programs, particularly those targeted at schools. An evidence based, coordinated approach to house fire injury prevention is critical, given current financial constraints and the potential for program overload for communities and schools. PMID:10518271

  6. Inferring oscillatory modulation in neural spike trains

    PubMed Central

    Arai, Kensuke; Kass, Robert E.

    2017-01-01

    Oscillations are observed at various frequency bands in continuous-valued neural recordings like the electroencephalogram (EEG) and local field potential (LFP) in bulk brain matter, and analysis of spike-field coherence reveals that spiking of single neurons often occurs at certain phases of the global oscillation. Oscillatory modulation has been examined in relation to continuous-valued oscillatory signals, and independently from the spike train alone, but behavior or stimulus triggered firing-rate modulation, spiking sparseness, presence of slow modulation not locked to stimuli and irregular oscillations with large variability in oscillatory periods, present challenges to searching for temporal structures present in the spike train. In order to study oscillatory modulation in real data collected under a variety of experimental conditions, we describe a flexible point-process framework we call the Latent Oscillatory Spike Train (LOST) model to decompose the instantaneous firing rate in biologically and behaviorally relevant factors: spiking refractoriness, event-locked firing rate non-stationarity, and trial-to-trial variability accounted for by baseline offset and a stochastic oscillatory modulation. We also extend the LOST model to accommodate changes in the modulatory structure over the duration of the experiment, and thereby discover trial-to-trial variability in the spike-field coherence of a rat primary motor cortical neuron to the LFP theta rhythm. Because LOST incorporates a latent stochastic auto-regressive term, LOST is able to detect oscillations when the firing rate is low, the modulation is weak, and when the modulating oscillation has a broad spectral peak. PMID:28985231

  7. Automated Wildfire Detection Through Artificial Neural Networks

    NASA Technical Reports Server (NTRS)

    Miller, Jerry; Borne, Kirk; Thomas, Brian; Huang, Zhenping; Chi, Yuechen

    2005-01-01

    We have tested and deployed Artificial Neural Network (ANN) data mining techniques to analyze remotely sensed multi-channel imaging data from MODIS, GOES, and AVHRR. The goal is to train the ANN to learn the signatures of wildfires in remotely sensed data in order to automate the detection process. We train the ANN using the set of human-detected wildfires in the U.S., which are provided by the Hazard Mapping System (HMS) wildfire detection group at NOAA/NESDIS. The ANN is trained to mimic the behavior of fire detection algorithms and the subjective decision- making by N O M HMS Fire Analysts. We use a local extremum search in order to isolate fire pixels, and then we extract a 7x7 pixel array around that location in 3 spectral channels. The corresponding 147 pixel values are used to populate a 147-dimensional input vector that is fed into the ANN. The ANN accuracy is tested and overfitting is avoided by using a subset of the training data that is set aside as a test data set. We have achieved an automated fire detection accuracy of 80-92%, depending on a variety of ANN parameters and for different instrument channels among the 3 satellites. We believe that this system can be deployed worldwide or for any region to detect wildfires automatically in satellite imagery of those regions. These detections can ultimately be used to provide thermal inputs to climate models.

  8. 40 CFR Appendix J to Subpart G of... - Substitutes listed in the January 29, 2002 Final Rule, effective April 1, 2002

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... from the fire protection system in conjunction with testing or servicing, and recycled for later use or... protective equipment (e.g., respiratory protection), fire protection, hazard communication, worker training...

  9. 40 CFR Appendix J to Subpart G of... - Substitutes listed in the January 29, 2002 Final Rule, effective April 1, 2002

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... from the fire protection system in conjunction with testing or servicing, and recycled for later use or... protective equipment (e.g., respiratory protection), fire protection, hazard communication, worker training...

  10. 40 CFR Appendix J to Subpart G of... - Substitutes listed in the January 29, 2002 Final Rule, effective April 1, 2002

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... from the fire protection system in conjunction with testing or servicing, and recycled for later use or... protective equipment (e.g., respiratory protection), fire protection, hazard communication, worker training...

  11. Fire safety of passenger trains : phase I : material evaluation (cone calorimeter)

    DOT National Transportation Integrated Search

    1999-01-01

    As part of the passenger equipment rulemaking required by Congress, the Federal Railroad Administration (FRA) has proposed that its existing fire safety guidelines be made mandatory. A major conclusion of a FRA-funded 1993 study by the National Insti...

  12. Comparison of the U.S. and European approaches to passenger train fire safety

    DOT National Transportation Integrated Search

    2012-09-28

    The Federal Railroad Administration (FRA) approach to passenger rail equipment fires safety requires the use of primarily small-scale flammability and smoke emission tests and performance criteria for interior materials, such as seats and wall and ce...

  13. Anomalous neuronal responses to fluctuated inputs

    NASA Astrophysics Data System (ADS)

    Hosaka, Ryosuke; Sakai, Yutaka

    2015-10-01

    The irregular firing of a cortical neuron is thought to result from a highly fluctuating drive that is generated by the balance of excitatory and inhibitory synaptic inputs. A previous study reported anomalous responses of the Hodgkin-Huxley neuron to the fluctuated inputs where an irregularity of spike trains is inversely proportional to an input irregularity. In the current study, we investigated the origin of these anomalous responses with the Hindmarsh-Rose neuron model, map-based models, and a simple mixture of interspike interval distributions. First, we specified the parameter regions for the bifurcations in the Hindmarsh-Rose model, and we confirmed that the model reproduced the anomalous responses in the dynamics of the saddle-node and subcritical Hopf bifurcations. For both bifurcations, the Hindmarsh-Rose model shows bistability in the resting state and the repetitive firing state, which indicated that the bistability was the origin of the anomalous input-output relationship. Similarly, the map-based model that contained bistability reproduced the anomalous responses, while the model without bistability did not. These results were supported by additional findings that the anomalous responses were reproduced by mimicking the bistable firing with a mixture of two different interspike interval distributions. Decorrelation of spike trains is important for neural information processing. For such spike train decorrelation, irregular firing is key. Our results indicated that irregular firing can emerge from fluctuating drives, even weak ones, under conditions involving bistability. The anomalous responses, therefore, contribute to efficient processing in the brain.

  14. KSC-2014-2805

    NASA Image and Video Library

    2014-05-01

    CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, Mark Huetter, assistant chief of Training for the center's Fire Rescue Department, is interviewed near the Shuttle Landing Facility. He discussed working with pilots in NASA Aircraft Operations to develop procedures for using agency helicopters to transport injured patients to a local hospital. The training activity took place in Kennedy's Launch Complex 39 turn-basin parking lot. It was part of a new training program developed by Kennedy's Fire Rescue department along with NASA Aircraft Operations to sharpen the skills needed to help rescue personnel learn how to collaborate with helicopter pilots in taking injured patients to hospitals as quickly as possible. Photo credit: NASA/Dimitri Gerondidakis

  15. KSC-2014-2806

    NASA Image and Video Library

    2014-05-01

    CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, Mark Huetter, assistant chief of Training for the center's Fire Rescue Department, is interviewed near the Shuttle Landing Facility. He discussed working with pilots in NASA Aircraft Operations to develop procedures for using agency helicopters to transport injured patients to a local hospital. The training activity took place in Kennedy's Launch Complex 39 turn-basin parking lot. It was part of a new training program developed by Kennedy's Fire Rescue department along with NASA Aircraft Operations to sharpen the skills needed to help rescue personnel learn how to collaborate with helicopter pilots in taking injured patients to hospitals as quickly as possible. Photo credit: NASA/Dimitri Gerondidakis

  16. KSC-2014-2794

    NASA Image and Video Library

    2014-04-30

    CAPE CANAVERAL, Fla. -- Following a training exercise at NASA's Kennedy Space Center in Florida, helicopter pilot Bill Martin, a URS Federal Technical Services in the agency's Aircraft Operations, left, confers with Mark Huetter of Chenega Security & Support Solutions. Martin serves as assistant chief of Training for the center's Fire Rescue Department. The activity taking place in Kennedy's Launch Complex 39 turn-basin parking lot was only one of several drills. It was part of a new training program that was developed by Kennedy's Fire Rescue department along with NASA Aircraft Operations to sharpen the skills needed to help rescue personnel learn how to collaborate with helicopter pilots in taking injured patients to hospitals as quickly as possible. Photo credit: NASA/Dan Casper

  17. Maturation of Spontaneous Firing Properties after Hearing Onset in Rat Auditory Nerve Fibers: Spontaneous Rates, Refractoriness, and Interfiber Correlations

    PubMed Central

    Wu, Jingjing Sherry; Young, Eric D.

    2016-01-01

    Auditory nerve fibers (ANFs) exhibit a range of spontaneous firing rates (SRs) that are inversely correlated with threshold for sounds. To probe the underlying mechanisms and time course of SR differentiation during cochlear maturation, loose-patch extracellular recordings were made from ANF dendrites using acutely excised rat cochlear preparations of different ages after hearing onset. Diversification of SRs occurred mostly between the second and the third postnatal week. Statistical properties of ANF spike trains showed developmental changes that approach adult-like features in older preparations. Comparison with intracellularly recorded EPSCs revealed that most properties of ANF spike trains derive from the characteristics of presynaptic transmitter release. Pharmacological tests and waveform analysis showed that endogenous firing produces some fraction of ANF spikes, accounting for their unusual properties; the endogenous firing diminishes gradually during maturation. Paired recordings showed that ANFs contacting the same inner hair cell could have different SRs, with no correlation in their spike timing. SIGNIFICANCE STATEMENT The inner hair cell (IHC)/auditory nerve fiber (ANF) synapse is the first synapse of the auditory pathway. Remarkably, each IHC is the sole partner of 10–30 ANFs with a range of spontaneous firing rates (SRs). Low and high SR ANFs respond to sound differently, and both are important for encoding sound information across varying acoustical environments. Here we demonstrate SR diversification after hearing onset by afferent recordings in acutely excised rat cochlear preparations. We describe developmental changes in spike train statistics and endogenous firing in immature ANFs. Dual afferent recordings provide the first direct evidence that fibers with different SRs contact the same IHCs and do not show correlated spike timing at rest. These results lay the groundwork for understanding the differential sensitivity of ANFs to acoustic trauma. PMID:27733610

  18. The three Rs of fire safety, emergency action, and fire prevention planning: promoting safety at the worksite.

    PubMed

    Thompson, Marcella R

    2003-04-01

    Fire safety is of paramount importance for everyone. In many workplaces, the occupational health nurse's scope of practice encompasses safety related activities. Included within this role is the responsibility for fire safety, emergency action, and fire prevention planning. The Three Rs of fire safety, emergency action, and fire prevention plans are rules, responsibilities, and resources. Myriad building and fire safety codes, regulations, and standards exist with which an employer must comply. An employer's responsibility for installing, testing, inspecting, and maintaining fire safety related equipment is extensive. Emergency action and fire prevention planning begins with conducting a detailed physical survey and preparing site maps. It includes making key policy decisions, writing procedures, and training employees in those procedures by practicing and executing site drills. The best resources available for emergency planning are the local fire department and the property insurer. Planning ahead means an efficient emergency response if disaster strikes. It saves lives, limits property damage, and preserves the environment.

  19. Detection of Wildfires with Artificial Neural Networks

    NASA Astrophysics Data System (ADS)

    Umphlett, B.; Leeman, J.; Morrissey, M. L.

    2011-12-01

    Currently fire detection for the National Oceanic and Atmospheric Administration (NOAA) using satellite data is accomplished with algorithms and error checking human analysts. Artificial neural networks (ANNs) have been shown to be more accurate than algorithms or statistical methods for applications dealing with multiple datasets of complex observed data in the natural sciences. ANNs also deal well with multiple data sources that are not all equally reliable or equally informative to the problem. An ANN was tested to evaluate its accuracy in detecting wildfires utilizing polar orbiter numerical data from the Advanced Very High Resolution Radiometer (AVHRR). Datasets containing locations of known fires were gathered from the NOAA's polar orbiting satellites via the Comprehensive Large Array-data Stewardship System (CLASS). The data was then calibrated and navigation corrected using the Environment for Visualizing Images (ENVI). Fires were located with the aid of shapefiles generated via ArcGIS. Afterwards, several smaller ten pixel by ten pixel datasets were created for each fire (using the ENVI corrected data). Several datasets were created for each fire in order to vary fire position and avoid training the ANN to look only at fires in the center of an image. Datasets containing no fires were also created. A basic pattern recognition neural network was established with the MATLAB neural network toolbox. The datasets were then randomly separated into categories used to train, validate, and test the ANN. To prevent over fitting of the data, the mean squared error (MSE) of the network was monitored and training was stopped when the MSE began to rise. Networks were tested using each channel of the AVHRR data independently, channels 3a and 3b combined, and all six channels. The number of hidden neurons for each input set was also varied between 5-350 in steps of 5 neurons. Each configuration was run 10 times, totaling about 4,200 individual network evaluations. Thirty network parameters were recorded to characterize performance. These parameters were plotted with various data display techniques to determine which network configuration was not only most accurate in fire classification, but also the most computationally efficient. The most accurate fire classification network used all six channels of AVHRR data to achieve an accuracy ranging from 73-90%.

  20. Secondary Fire Analysis.

    DTIC Science & Technology

    1981-09-01

    of wood frame and brick veneer, slab on grade construction), killed 33, injured more than 1,000, derailed a train, destroyed 4,000 cars, uprooted most... of a nuclear detonation) in or near structures, with emphasis on critical facil- ities and industries. Assessment of the potential for secondary fires...and/or 517 East Dayshore, Redwood City, CA 94063 DistI pial (DETACHABLE SUMMARY) SECONDARY FIRE ANALYSIS This report presents the results of a

  1. 49 CFR 195.403 - Emergency response training.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... to minimize the potential for fire, explosion, toxicity, or environmental damage; and (5) Learn the... changes to the emergency response training program as necessary to ensure that it is effective. (c) Each...

  2. 49 CFR 195.403 - Emergency response training.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... to minimize the potential for fire, explosion, toxicity, or environmental damage; and (5) Learn the... changes to the emergency response training program as necessary to ensure that it is effective. (c) Each...

  3. 49 CFR 195.403 - Emergency response training.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... to minimize the potential for fire, explosion, toxicity, or environmental damage; and (5) Learn the... changes to the emergency response training program as necessary to ensure that it is effective. (c) Each...

  4. 49 CFR 195.403 - Emergency response training.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... to minimize the potential for fire, explosion, toxicity, or environmental damage; and (5) Learn the... changes to the emergency response training program as necessary to ensure that it is effective. (c) Each...

  5. Reality-based practice under pressure improves handgun shooting performance of police officers.

    PubMed

    Oudejans, R R D

    2008-03-01

    The current study examined whether reality-based practice under pressure may help in preventing degradation of handgun shooting performance under pressure for police officers. Using a pre-post-test design, one group of nine police officers practised handgun shooting under pressure evoked by an opponent who also fired back using marking (coloured soap) cartridges. The control group (n = 8) practised handgun shooting on standard cardboard targets instead of real opponents. Within a fortnight after the pre-test, both groups received three training sessions of 1 h, in which each person fired a total of 72 rounds. During the pre- and post test each participant took 30 shots without pressure (cardboard targets) and 30 shots under additional pressure (with an opponent firing back). While during the pre-test both groups performed worse in front of an opponent firing back compared to the cardboard targets, after the training sessions shooting performance of the experimental group no longer deteriorated with an opponent while performance of the control group was equally harmed as during the pre-test. These results indicate that training exercises involving increased pressure can acclimatize shooting performance of ordinary police officers to those situations with elevated pressure that they may encounter during their police work.

  6. Expedition 21 Crew Members participate in Fire Drill/OBT

    NASA Image and Video Library

    2009-10-15

    ISS021-E-007175 (15 Oct. 2009) --- European Space Agency astronaut Frank De Winne (left), Expedition 21 commander; and Canadian Space Agency astronaut Robert Thirsk, flight engineer, conduct an onboard training (OBT) fire drill in the Columbus laboratory of the International Space Station.

  7. Franklin Pierce College's Fire Department: 17 Student Volunteers and a Vintage Engine.

    ERIC Educational Resources Information Center

    Meyer, Thomas J.

    1985-01-01

    Seventeen student volunteers form the Franklin Pierce College Fire Department. When the firefighters are on duty, they must carry electronic pagers at all times. They also participate in dormitory inspections and attend weekend sessions at a local firefighters' training school. (MLW)

  8. Uniform Corrosion and General Dissolution of Aluminum Alloys 2024-T3, 6061-T6, and 7075-T6

    NASA Astrophysics Data System (ADS)

    Huang, I.-Wen

    Uniform corrosion and general dissolution of aluminum alloys was not as well-studied in the past, although it was known for causing significant amount of weight loss. This work comprises four chapters to understand uniform corrosion of aluminum alloys 2024-T3, 6061-T6, and 7075-T6. A preliminary weight loss experiment was performed for distinguishing corrosion induced weight loss attributed to uniform corrosion and pitting corrosion. The result suggested that uniform corrosion generated a greater mass loss than pitting corrosion. First, to understand uniform corrosion mechanism and kinetics in different environments, a series of static immersion tests in NaCl solutions were performed to provide quantitative measurement of uniform corrosion. Thereafter, uniform corrosion development as a function of temperature, pH, Cl-, and time was investigated to understand the influence of environmental factors. Faster uniform corrosion rate has been found at lower temperature (20 and 40°C) than at higher temperature (60 and 80°C) due to accelerated corrosion product formation at high temperatures inhibiting corrosion reactions. Electrochemical tests including along with scanning electron microscopy (SEM) were utilized to study the temperature effect. Second, in order to further understand the uniform corrosion influence on pit growth kinetics, a long term exposures for 180 days in both immersion and ASTM-B117 test were performed. Uniform corrosion induced surface recession was found to have limited impact on pit geometry regardless of exposure methods. It was also found that the competition for limited cathodic current from uniform corrosion the primary rate limiting factor for pit growth. Very large pits were found after uniform corrosion growth reached a plateau due to corrosion product coverage. Also, optical microscopy and focused ion beam (FIB) imaging has provided more insights of distinctive pitting geometry and subsurface damages found from immersion samples and B117 samples. Although uniform corrosion was studied in various electrolytes, the pH impact was still difficult to discern due to ongoing cathodic reactions that changed electrolyte pH with time. Therefore, buffered pH electrolytes with pH values of 3, 5, 8, and 10 were prepared static immersion tests. Electrochemical experiments were performed in each buffered pH conditions for understanding corrosion mechanisms. Uniform corrosion was found exhibiting higher corrosion rate in buffered acidic and alkaline electrolytes due to pH- and temperature-dependent corrosion product precipitation. Observations were supported by electrochemical, SEM, and EDS observations. Due to the complexity of corrosion data, a reliable corrosion prediction based on empirical observations could be challenging. Artificial neural network (ANN) modeling was used for corrosion data pattern recognition by mimicking human neural network systems. Predictive models were developed based on corrosion data acquired in this study. The model was adaptable through iteratively update its prediction by error minimization during the training phase. Trained ANN model can predict uniform corrosion successfully. In addition to ANN, fuzzy curve analysis was utilized to rank the influence of each input (temperature, pH, Cl-, and time). For example, temperature and pH were found to be the most influential parameters to uniform corrosion. This information can provide feedback for ANN improvement, also known as "data pruning".

  9. Sodium-dependent phosphate cotransporters and phosphate-induced calcification of vascular smooth muscle cells: Redundant roles for PiT-1 and PiT-2

    PubMed Central

    Crouthamel, Matthew H.; Lau, Wei Ling; Leaf, Elizabeth M.; Chavkin, Nick; Wallingford, Mary C.; Peterson, Danielle F.; Li, Xianwu; Liu, Yonggang; Chin, Michael T.; Levi, Moshe; Giachelli, Cecilia M.

    2014-01-01

    Objective Elevated serum phosphate has emerged as a major risk factor for vascular calcification. The sodium-dependent phosphate cotransporter, PiT-1, was previously shown to be required for phosphate-induced osteogenic differentiation and calcification of cultured human VSMCs, but its importance in vascular calcification in vivo, as well as the potential role of its homologue, PiT-2, have not been determined. We investigated the in vivo requirement for PiT-1 in vascular calcification using a mouse model of chronic kidney disease, and the potential compensatory role of PiT-2 using in vitro knockdown and over-expression strategies. Approach and Results Mice with targeted deletion of PiT-1 in VSMCs were generated (PiT-1Δsm). PiT-1 mRNA levels were undetectable whereas PiT-2 mRNA levels were increased 2 fold in the vascular aortic media of PiT-1Δsm compared to PiT-1flox/flox control. When arterial medial calcification was induced in PiT-1Δsm and PiT-1flox/flox by chronic kidney disease followed by dietary phosphate loading, the degree of aortic calcification was not different between genotypes, suggesting compensation by PiT-2. Consistent with this possibility, VSMCs isolated from PiT-1Δsm mice had no PiT-1 mRNA expression, increased PiT-2 mRNA levels, and no difference in sodium-dependent phosphate uptake or phosphate-induced matrix calcification compared to PiT-1flox/flox VSMCs. Knockdown of PiT-2 decreased phosphate uptake and phosphate-induced calcification of PiT-1Δsm VSMCs. Furthermore, over-expression of PiT-2 restored these parameters in human PiT-1-deficient VSMCs. Conclusions PiT-2 can mediate phosphate uptake and calcification of VSMCs in the absence of PiT-1. Mechanistically, PiT-1 and PiT-2 appear to serve redundant roles in phosphate-induced calcification of vascular smooth muscle cells. PMID:23968976

  10. KSC-2011-6642

    NASA Image and Video Library

    2011-08-31

    CAPE CANAVERAL, Fla. -- Volunteers, portraying their individual roles, stand beside a NASA Fire Rescue Services vehicle and a Huey II helicopter in support of the aviation safety exercise during Emergency Response Safety Training at the Shuttle Landing Facility, Runway 33, at NASA’s Kennedy Space Center in Florida. The simulated helicopter mishap exercise was conducted to evaluate emergency response and mishap investigations of aircraft at Kennedy. Participants included Air Rescue Fire Fighters, Flight Operations, Disaster Preparedness, Security, and Safety. NASA mandates simulated aviation safety training take place every two years. Photo credit: NASA/Kim Shiflett

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Preliminary Assessment/Site Inspection Report of Areas Of concern (AOC) A thru F at WK Kellogg, Battle Creek, MI. A Preliminary Assessment/Site Inspection was performed on 6 AOC`s at WK Kellogg to confirm or deny the presence of contamination a the AOC`s. The AOC`s involved in this investigation include. AOC A, Waste Accumulation Area; AOC B, Motor Pool Drainage Ditch; AOC C, Fire Training Area South; AOC D, Fire Training Area West; AOC E, Old Hanger (Building 6900); AOC F, New Hanger (Building 6901). The recommendation is for AOC`s A and B continue to the RI/FS stage.

  12. Gold grade variation and particle microchemistry in exploration pits of the Batouri gold district, SE Cameroon

    NASA Astrophysics Data System (ADS)

    Vishiti, A.; Suh, C. E.; Lehmann, B.; Egbe, J. A.; Shemang, E. M.

    2015-11-01

    The Batouri area hosts lode-gold mineralization under several-m-thick lateritic cover. Pitting to bed rock on a geochemical Au anomaly defined from previous reconnaissance soil sampling identified five horizons ranging from saprock at the base to laterite at the top. Analysis of bulk samples from each horizon by fire assay shows that most of the horizons are barren although 119 ppb and 48 ppb Au values were obtained from one laterite horizon and one saprolite horizon, respectively, from two separate pits. All the horizons were panned and particulate gold was also recovered only from these two horizons. The gold grains from both horizons are morphologically and compositionally indistinguishable with rare quartz, pyrite and galena inclusions. The grains have irregular, sub-rounded, bean to elongated shapes and they show a remarkable core-rim zonation. Electron microprobe analysis of the grains recorded high gold content in the rims (86.3-100 wt%) and along fissures within the grains (95.1-100 wt%). The cores are relatively Ag rich (11.8-14 wt% Ag) while the rims (0.63-13.7 wt% Ag, most of the values fall within the lower limit of this range) and fissures (0.03-5.02 wt% Ag) are poor in Ag. The low Ag concentration in the rims and along fissures is attributed to preferential leaching of Ag; a process recognized in gold grains and platiniferous alloys from alluvia. The core composition of the grains is similar to that of primary gold composition in the bedrock. These results show that gold in the soil is relic particulate gold derived from the primary source with no evidence of secondary gold precipitation in the weathering cycle. In all the pits no horizon was systematically enriched in gold suggesting there has been no chemical remobilization of gold in this environment. Rather the dispersion of gold here is in the particulate form. Therefore combining particulate gold features with assay data is relevant to exploration in such tropical environments.

  13. Prevention and suppression of metal packing fires.

    PubMed

    Roberts, Mark; Rogers, William J; Sam Mannan, M; Ostrowski, Scott W

    2003-11-14

    Structured packing has been widely used because of large surface area that makes possible columns with high capacity and efficiency. The large surface area also contributes to fire hazards because of hydrocarbon deposits that can easily combust and promote combustion of the thin metal packing materials. Materials of high surface area that can fuel fires include reactive metals, such as titanium, and materials that are not considered combustible, such as stainless steel. Column design and material selection for packing construction is discussed together with employee training and practices for safe column maintenance and operations. Presented also are methods and agents for suppression of metal fires. Guidance for prevention and suppression of metal fires is related to incidents involving packing fires in columns.

  14. A novel pit pattern identifies the precursor of colorectal cancer derived from sessile serrated adenoma.

    PubMed

    Kimura, Tomoaki; Yamamoto, Eiichiro; Yamano, Hiro-O; Suzuki, Hiromu; Kamimae, Seiko; Nojima, Masanori; Sawada, Takeshi; Ashida, Masami; Yoshikawa, Kenjiro; Takagi, Ryo; Kato, Ryusuke; Harada, Taku; Suzuki, Ryo; Maruyama, Reo; Kai, Masahiro; Imai, Kohzoh; Shinomura, Yasuhisa; Sugai, Tamotsu; Toyota, Minoru

    2012-03-01

    Sessile serrated adenomas (SSAs) are known to be precursors of sporadic colorectal cancers (CRCs) with microsatellite instability (MSI), and to be tightly associated with BRAF mutation and the CpG island methylator phenotype (CIMP). Consequently, colonoscopic identification of SSAs has important implications for preventing CRCs, but accurate endoscopic diagnosis is often difficult. Our aim was to clarify which endoscopic findings are specific to SSAs. The morphological, histological and molecular features of 261 specimens from 226 colorectal tumors were analyzed. Surface microstructures were analyzed using magnifying endoscopy. Mutation in BRAF and KRAS was examined by pyrosequencing. Methylation of p16, IGFBP7, MLH1 and MINT1, -2, -12 and -31 was analyzed using bisulfite pyrosequencing. Through retrospective analysis of a training set (n=145), we identified a novel surface microstructure, the Type II open-shape pit pattern (Type II-O), which was specific to SSAs with BRAF mutation and CIMP. Subsequent prospective analysis of an independent validation set (n=116) confirmed that the Type II-O pattern is highly predictive of SSAs (sensitivity, 65.5%; specificity, 97.3%). BRAF mutation and CIMP occurred with significant frequency in Type II-O-positive serrated lesions. Progression of SSAs to more advanced lesions was associated with further accumulation of aberrant DNA methylation and additional morphological changes, including the Type III, IV and V pit patterns. Our results suggest the Type II-O pit pattern is a useful hallmark of the premalignant stage of CRCs with MSI and CIMP, which could serve to improve the efficacy of colonoscopic surveillance.

  15. Nobody’s perfect: can irregularities in pit structure influence vulnerability to cavitation?

    PubMed Central

    Plavcová, Lenka; Jansen, Steven; Klepsch, Matthias; Hacke, Uwe G.

    2013-01-01

    Recent studies have suggested that species-specific pit properties such as pit membrane thickness, pit membrane porosity, torus-to-aperture diameter ratio and pit chamber depth influence xylem vulnerability to cavitation. Despite the indisputable importance of using mean pit characteristics, considerable variability in pit structure within a single species or even within a single pit field should be acknowledged. According to the rare pit hypothesis, a single pit that is more air-permeable than many neighboring pits is sufficient to allow air-seeding. Therefore, any irregularities or morphological abnormalities in pit structure allowing air-seeding should be associated with increased vulnerability to cavitation. Considering the currently proposed models of air-seeding, pit features such as rare, large pores in the pit membrane, torus extensions, and plasmodesmatal pores in a torus can represent potential glitches. These aberrations in pit structure could either result from inherent developmental flaws, or from damage caused to the pit membrane by chemical and physical agents. This suggests the existence of interesting feedbacks between abiotic and biotic stresses in xylem physiology. PMID:24273549

  16. Battle Command Staff Training

    DTIC Science & Technology

    1992-12-01

    warfare ? • How does one develop training exercises to exploit this medium? • What are some of the implications for institutional training? The DARPA...IDT Inactive Duty Training JEW IIntelligencel•ectronic Warfare I FOR Intelligent Forces IPB Intelligence Preparation of the Battlefield JAAT Joint Air... Chemical xiI NFA No Fire Area NGB Nationhl Guard Bureau NTC National Training Center OAC Officers Advanced Cours- OC Observer/Controllcr OCI Observer

  17. The Effect of Ratio and Interval Training on Pavlovian-Instrumental Transfer in Mice

    PubMed Central

    Wiltgen, Brian J.; Sinclair, Courtney; Lane, Chadrick; Barrows, Frank; Molina, Martín; Chabanon-Hicks, Chloe

    2012-01-01

    Conditional stimuli (CS) that are paired with reward can be used to motivate instrumental responses. This process is called Pavlovian-instrumental transfer (PIT). A recent study in rats suggested that habitual responses are particularly sensitive to the motivational effects of reward cues. The current experiments examined this idea using ratio and interval training in mice. Two groups of animals were trained to lever press for food pellets that were delivered on random ratio or random interval schedules. Devaluation tests revealed that interval training led to habitual responding while ratio training produced goal-directed actions. The presentation of CSs paired with reward led to positive transfer in both groups, however, the size of this effect was much larger in mice that were trained on interval schedules. This result suggests that habitual responses are more sensitive to the motivational influence of reward cues than goal-directed actions. The implications for neurobiological models of motivation and drug seeking behaviors are discussed. PMID:23144742

  18. 30 CFR 57.4362 - Underground rescue and firefighting operations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4362 Underground rescue and firefighting operations. Following evacuation of a mine in a fire emergency, only persons wearing and trained...

  19. Pervasive Agility and Agile Fires in Support of Decisive Action

    DTIC Science & Technology

    2012-03-29

    Pervasive Agility and Agile Fires in Support of Decisive Action FORMAT: Civilian Research Project DATE: 29 March 2012 WORD COUNT : 12,599 PAGES: 54...will face, this pollenization may require creative measures, perhaps virtual or constructive scenarios. The National Training Center at Fort Irwin

  20. 30 CFR 77.1100 - Fire protection; training and organization.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....1100 Section 77.1100 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF... facilities and equipment shall be provided commensurate with the potential fire hazards at each structure...

  1. Military Training Lands Historic Context: Large Arms Ranges

    DTIC Science & Technology

    2010-03-01

    materials. The associated materials used with flamethrowers included gasoline and Diesel oil, and coconut fatty acids , oleic acids , and naphthenic acids ...The supply of loaded ammunition clips was replenished. At the command CEASE FIRING, the firer removed his foot from the 40mm anti-aircraft gun firing...to fire. If the misfired round could not be extracted in the normal manner, it was removed under the direct supervision of an officer using a

  2. The Joint Fire Science Program Fire Exchange Network: Facilitating Knowledge Exchange About Wildland Fire Science Across the U.S.

    NASA Astrophysics Data System (ADS)

    York, A.; Blocksome, C.; Cheng, T.; Creighton, J.; Edwards, G.; Frederick, S.; Giardina, C. P.; Goebel, P. C.; Gucker, C.; Kobziar, L.; Lane, E.; Leis, S.; Long, A.; Maier, C.; Marschall, J.; McGowan-Stinski, J.; Mohr, H.; MontBlanc, E.; Pellant, M.; Pickett, E.; Seesholtz, D.; Skowronski, N.; Stambaugh, M. C.; Stephens, S.; Thode, A.; Trainor, S. F.; Waldrop, T.; Wolfson, B.; Wright, V.; Zedler, P.

    2014-12-01

    The Joint Fire Science Program's (JFSP) Fire Exchange Network is actively working to accelerate the awareness, understanding, and adoption of wildland fire science information by federal, tribal, state, local, and private stakeholders within ecologically similar regions. Our network of 15 regional exchanges provides timely, accurate, and regionally relevant science-based information to assist with fire management challenges. Regional activities, through which we engage fire and resource managers, scientists, and private landowners, include online newsletters and announcements, social media, regionally focused web-based clearinghouses of relevant science, field trips and demonstration sites, workshops and conferences, webinars and online training, and syntheses and fact sheets. Exchanges also help investigators design research that is relevant to regional management needs and assist with technology transfer to management audiences. This poster provides an introduction to and map of the regional exchanges.

  3. [Forest lighting fire forecasting for Daxing'anling Mountains based on MAXENT model].

    PubMed

    Sun, Yu; Shi, Ming-Chang; Peng, Huan; Zhu, Pei-Lin; Liu, Si-Lin; Wu, Shi-Lei; He, Cheng; Chen, Feng

    2014-04-01

    Daxing'anling Mountains is one of the areas with the highest occurrence of forest lighting fire in Heilongjiang Province, and developing a lightning fire forecast model to accurately predict the forest fires in this area is of importance. Based on the data of forest lightning fires and environment variables, the MAXENT model was used to predict the lightning fire in Daxing' anling region. Firstly, we studied the collinear diagnostic of each environment variable, evaluated the importance of the environmental variables using training gain and the Jackknife method, and then evaluated the prediction accuracy of the MAXENT model using the max Kappa value and the AUC value. The results showed that the variance inflation factor (VIF) values of lightning energy and neutralized charge were 5.012 and 6.230, respectively. They were collinear with the other variables, so the model could not be used for training. Daily rainfall, the number of cloud-to-ground lightning, and current intensity of cloud-to-ground lightning were the three most important factors affecting the lightning fires in the forest, while the daily average wind speed and the slope was of less importance. With the increase of the proportion of test data, the max Kappa and AUC values were increased. The max Kappa values were above 0.75 and the average value was 0.772, while all of the AUC values were above 0.5 and the average value was 0. 859. With a moderate level of prediction accuracy being achieved, the MAXENT model could be used to predict forest lightning fire in Daxing'anling Mountains.

  4. Landscape characteristics of disturbed shrubsteppe habitats in southwestern Idaho (USA)

    USGS Publications Warehouse

    Knick, Steven T.; Rotenberry, J.T.

    1997-01-01

    We compared 5 zones in shrubsteppe habitats of southwestern Idaho to determine the effect of differing disturbance combinations on landscapes that once shared historically similar disturbance regimes. The primary consequence of agriculture, wildfires, and extensive fires ignited by the military during training activities was loss of native shrubs from the landscape. Agriculture created large square blocks on the landscape, and the landscape contained fewer small patches and more large shrub patches than non-agricultural areas. In contrast, fires left a more fragmented landscape. Repeated fires did not change the distribution of patch sizes, but decreased the total area of remaining shrublands and increased the distance between remaining shrub patches that provide seed sources. Military training with tracked vehicles was associated with a landscape characterized by small, closely spaced, shrub patches. Our results support the general model hypothesized for conversion of shrublands to annual grasslands by disturbance. Larger shrub patches in our region, historically resistant to fire spread and large-scale fires because of a perennial bunchgrass understory, were more fragmented than small patches. Presence of cheatgrass (Bromus tectorum), an exotic annual, was positively related to landscape patchiness and negatively related to number of shrub cells. Thus, cheatgrass dominance can contribute to further fragmentation and loss of the shrub patch by facilitating spread of subsequent fires, carried by continuous fuels, through the patch. The synergistic processes of fragmentation of shrub patches by disturbance, invasion and subsequent dominance by exotic annuals, and fire are converting shrubsteppe in southwestern Idaho to a new state dominated by exotic annual grasslands and high fire frequencies.

  5. General Employee Training Live, Course 15503

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gabel, Daniel Glen; Hughes, Heather

    This training at Los Alamos National Laboratory contains the following sections: Introduction to the Laboratory, Institutional Quality Assurance, Facilities, Policies, Procedures, and Other Requirements, Safety Expectations, Worker Protection: Occupational Safety and Health, Industrial Hygiene and Safety, Lockout/Tagout, General Employee Radiological Training, Fire Protection, Security, Emergency Operations, Occupational Health, and Environment.

  6. Technical Training for Managers.

    ERIC Educational Resources Information Center

    Haverland, Edgar M.

    The question has arisen as to what kind of information a manager without extensive technical training needs to learn to supervise effectively. For example, the Nike Hercules fire control platoon leader, usually an officer in his first active duty assignment, seldom has had extensive technical training. Yet he is responsibile for the…

  7. Communication and Diversity: Innovations in Teacher Education

    ERIC Educational Resources Information Center

    Simonds, Brent K.; Lippert, Lance R.; Hunt, Stephen K.; Angell, Maureen E.; Moore, Marilyn K.

    2008-01-01

    Teacher education programs have increasingly come under fire for not providing pre-service teachers communication skills training. Given that such training is essential to address diversity in the classroom and to meet the day-to-day functioning of teachers, higher education must provide communication skills training for teacher certification.…

  8. PYRONES: pyro-modeling and evacuation simulation system

    NASA Astrophysics Data System (ADS)

    Kanellos, Tassos; Doulgerakis, Adam; Georgiou, Eftichia; Kountouriotis, Vassilios I.; Paterakis, Manolis; Thomopoulos, Stelios C. A.; Pappou, Theodora; Vrahliotis, Socrates I.; Rekouniotis, Thrasos; Protopsaltis, Byron; Rozenberg, Ofir; Livneh, Ofer

    2016-05-01

    Structural fires continue to pose a great threat towards human life and property. Due to the complexity and non-deterministic characteristics of a building fire disaster, it is not a straightforward task to assess the effectiveness of fire protection measures embedded in the building design, planned evacuation strategies and potential modes of response for mitigating the fire's consequences. Additionally, there is a lack of means that realistically and accurately recreate the conditions of building fire disasters for the purpose of training personnel in order to be sufficiently prepared when vis-a-vis with such an environment. The propagation of fire within a building, the diffusion of its volatile products, the behavior of the occupants and the sustained injuries not only exhibit non-linear behaviors as individual phenomena, but are also intertwined in a web of co-dependencies. The PYRONES system has been developed to address all these aspects through a comprehensive approach that relies on accurate and realistic computer simulations of the individual phenomena and their interactions. PYRONES offers innovative tools and services to strategically targeted niches in two market domains. In the domain of building design and engineering, PYRONES is seamlessly integrated within existing engineering Building Information Modelling (BIM) workflows and serves as a building performance assessment platform, able to evaluate fire protection systems. On another front, PYRONES penetrates the building security management market, serving as a holistic training platform for specialists in evacuation strategy planning, firefighters and first responders, both at a Command and Control and at an individual trainee level.

  9. The application of neural networks to the SSME startup transient

    NASA Technical Reports Server (NTRS)

    Meyer, Claudia M.; Maul, William A.

    1991-01-01

    Feedforward neural networks were used to model three parameters during the Space Shuttle Main Engine startup transient. The three parameters were the main combustion chamber pressure, a controlled parameter, the high pressure oxidizer turbine discharge temperature, a redlined parameter, and the high pressure fuel pump discharge pressure, a failure-indicating performance parameter. Network inputs consisted of time windows of data from engine measurements that correlated highly to the modeled parameter. A standard backpropagation algorithm was used to train the feedforward networks on two nominal firings. Each trained network was validated with four additional nominal firings. For all three parameters, the neural networks were able to accurately predict the data in the validation sets as well as the training set.

  10. X-ray microtomography study of otic capsule deficiencies: three-dimensional modelling of the fissula ante fenestram.

    PubMed

    Lee, J W; Sale, P; Patel, N P

    2015-09-01

    The postulated sites of perilymph fistulae involve otic capsule deficiencies, in particular, at the fissula ante fenestram. Histological studies have revealed this to be a channel extending from the middle ear, and becoming continuous with the inner ear medial to the anterior limit of the oval window. The relationship between a patent fissula and symptoms of perilymph fistula is contentious. The understanding of the anatomy of the fissula ante fenestram is incomplete. Histopathology is inherently destructive to the delicate ultrastructure of the middle and inner ear. Conversely, X-ray microtomography allows non-destructive examination of the otic capsule. In this study, we used X-ray microtomography to characterise the fissula ante fenestram. We imaged cadaveric temporal bones with X-ray microtomography. We used the Avizo Fire (Visualization Science Group, Merignac Cedex, France) software to perform post-processing and image analysis. Three-dimensional modelling of the fissula ante fenestram allowed stratification into four forms: rudimentary pit; partial fissula; complete occluded fissula; and complete patent fissula. X-ray microtomography showed that the fissula ante fenestram is present in various forms from rudimentary pit to complete deficiency of the otic capsule. This understanding may have implications for otologic surgery and clinical diagnosis of perilymph fistula.

  11. 46 CFR 15.1105 - Familiarization and basic training (BT).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... onboard about elementary safety matters and understand informational symbols, signs, and alarm signals concerning safety; (ii) Knows what to do if a person falls overboard; if fire or smoke is detected; or if the fire alarm or abandon-ship alarm sounds; (iii) Can identify stations for muster and embarkation, and...

  12. KSC-00pp1445

    NASA Image and Video Library

    2000-09-14

    KENNEDY SPACE CENTER, FLA. -- Firefighters surround a burning simulated aircraft during training exercises Cape Canaveral Air Force Station Pad 30. Those at left wait their turn as the crew on the right turn their hoses toward the fire. The firefighters are with Fire and Emergency Services at the Naval Station Mayport, Fla

  13. KSC00pp1445

    NASA Image and Video Library

    2000-09-14

    KENNEDY SPACE CENTER, FLA. -- Firefighters surround a burning simulated aircraft during training exercises Cape Canaveral Air Force Station Pad 30. Those at left wait their turn as the crew on the right turn their hoses toward the fire. The firefighters are with Fire and Emergency Services at the Naval Station Mayport, Fla

  14. Fire Officer I Lesson Plans.

    ERIC Educational Resources Information Center

    Pribyl, Paul F.

    Lesson plans are provided for the Fire Officer I course. Material for each lesson is presented in this format: course title, lesson title, equipment required, training aids needed, and a content outline which details teaching points and related instructor references. These references, or suggested readings, are listed at the conclusion of each…

  15. Chaos-induced modulation of reliability boosts output firing rate in downstream cortical areas.

    PubMed

    Tiesinga, P H E

    2004-03-01

    The reproducibility of neural spike train responses to an identical stimulus across different presentations (trials) has been studied extensively. Reliability, the degree of reproducibility of spike trains, was found to depend in part on the amplitude and frequency content of the stimulus [J. Hunter and J. Milton, J. Neurophysiol. 90, 387 (2003)]. The responses across different trials can sometimes be interpreted as the response of an ensemble of similar neurons to a single stimulus presentation. How does the reliability of the activity of neural ensembles affect information transmission between different cortical areas? We studied a model neural system consisting of two ensembles of neurons with Hodgkin-Huxley-type channels. The first ensemble was driven by an injected sinusoidal current that oscillated in the gamma-frequency range (40 Hz) and its output spike trains in turn drove the second ensemble by fast excitatory synaptic potentials with short term depression. We determined the relationship between the reliability of the first ensemble and the response of the second ensemble. In our paradigm the neurons in the first ensemble were initially in a chaotic state with unreliable and imprecise spike trains. The neurons became entrained to the oscillation and responded reliably when the stimulus power was increased by less than 10%. The firing rate of the first ensemble increased by 30%, whereas that of the second ensemble could increase by an order of magnitude. We also determined the response of the second ensemble when its input spike trains, which had non-Poisson statistics, were replaced by an equivalent ensemble of Poisson spike trains. The resulting output spike trains were significantly different from the original response, as assessed by the metric introduced by Victor and Purpura [J. Neurophysiol. 76, 1310 (1996)]. These results are a proof of principle that weak temporal modulations in the power of gamma-frequency oscillations in a given cortical area can strongly affect firing rate responses downstream by way of reliability in spite of rather modest changes in firing rate in the originating area.

  16. 60. Photographic copy of historic photo, April 25, 1907 (original ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    60. Photographic copy of historic photo, April 25, 1907 (original print filed in Record Group 115, National Archives, Washington, D.C.). UPPER DEER FLAT EMBANKMENT. STEAM SHOVEL NO. 1 LOADING CARS IN EASTERLY BORROW PIT. CARS IN THIS TRAIN OF 12 NEARLY ALL LOADED. EAIGHT MINUTES REQUIRED TO LOAD 12 CARS EQUAL TO 42 CU YDS. PLACE MEASUREMENT. - Boise Project, Deer Flat Embankments, Lake Lowell, Nampa, Canyon County, ID

  17. Microwave Radiometers for Fire Detection in Trains: Theory and Feasibility Study.

    PubMed

    Alimenti, Federico; Roselli, Luca; Bonafoni, Stefania

    2016-06-17

    This paper introduces the theory of fire detection in moving vehicles by microwave radiometers. The system analysis is discussed and a feasibility study is illustrated on the basis of two implementation hypotheses. The basic idea is to have a fixed radiometer and to look inside the glass windows of the wagon when it passes in front of the instrument antenna. The proposed sensor uses a three-pixel multi-beam configuration that allows an image to be formed by the movement of the train itself. Each pixel is constituted by a direct amplification microwave receiver operating at 31.4 GHz. At this frequency, the antenna can be a 34 cm offset parabolic dish, whereas a 1 K brightness temperature resolution is achievable with an overall system noise figure of 6 dB, an observation bandwidth of 2 GHz and an integration time of 1 ms. The effect of the detector noise is also investigated and several implementation hypotheses are discussed. The presented study is important since it could be applied to the automatic fire alarm in trains and moving vehicles with dielectric wall/windows.

  18. Microwave Radiometers for Fire Detection in Trains: Theory and Feasibility Study †

    PubMed Central

    Alimenti, Federico; Roselli, Luca; Bonafoni, Stefania

    2016-01-01

    This paper introduces the theory of fire detection in moving vehicles by microwave radiometers. The system analysis is discussed and a feasibility study is illustrated on the basis of two implementation hypotheses. The basic idea is to have a fixed radiometer and to look inside the glass windows of the wagon when it passes in front of the instrument antenna. The proposed sensor uses a three-pixel multi-beam configuration that allows an image to be formed by the movement of the train itself. Each pixel is constituted by a direct amplification microwave receiver operating at 31.4 GHz. At this frequency, the antenna can be a 34 cm offset parabolic dish, whereas a 1 K brightness temperature resolution is achievable with an overall system noise figure of 6 dB, an observation bandwidth of 2 GHz and an integration time of 1 ms. The effect of the detector noise is also investigated and several implementation hypotheses are discussed. The presented study is important since it could be applied to the automatic fire alarm in trains and moving vehicles with dielectric wall/windows. PMID:27322280

  19. Use of VR Technology and Passive Haptics for MANPADS Training System

    DTIC Science & Technology

    2017-09-01

    this setup also does not offer a variety of challenging scenarios needed for good training as the aircraft are mostly flying in landing or take-off... customized high-fidelity immersive training facilities are limited. Moreover, low trainee throughput from such high-end facilities is an ongoing obstacle...opportunities allow few operators to fire during live exercises. Simulation training is effective, but customized high-fidelity immersive training

  20. Potential Operating Room Fire Hazard of Bone Cement.

    PubMed

    Sibia, Udai S; Connors, Kevin; Dyckman, Sarah; Zahiri, Hamid R; George, Ivan; Park, Adrian E; MacDonald, James H

    Approximately 600 cases of operating room (OR) fires are reported annually. Despite extensive fire safety education and training, complete elimination of OR fires still has not been achieved. Each fire requires an ignition source, a fuel source, and an oxidizer. In this case report, we describe the potential fire hazard of bone cement in the OR. A total knee arthroplasty was performed with a standard medial parapatellar arthrotomy. Tourniquet control was used. After bone cement was applied to the prepared tibial surface, the surgeon used an electrocautery device to resect residual lateral meniscus tissue-and started a fire in the operative field. The surgeon suffocated the fire with a dry towel and prevented injury to the patient. We performed a PubMed search with a cross-reference search for relevant papers and found no case reports outlining bone cement as a potential fire hazard in the OR. To our knowledge, this is the first case report identifying bone cement as a fire hazard. OR fires related to bone cement can be eliminated by correctly assessing the setting time of the cement and avoiding application sites during electrocautery.

  1. KSC-04pd1655

    NASA Image and Video Library

    2004-08-05

    KENNEDY SPACE CENTER, FLA. - At the ribbon cutting for the Enhanced Firing Range on Schwartz Rd. at Kennedy Space Center, Dave Saleeba practices firing on the new range. Saleeba is assistant administrator with the Office of Security Management and Safeguards at NASA Headquarters and was a guest speaker at the ceremony. NASA’s Federal Law Enforcement Training Academy’s firing range has been upgraded to include a “rifle-grade” shoot house, a portable, tactical “shoot-back” trailer for cover and concealment drills, automated running targets and a new classroom facility. They are added to the existing three firearms ranges, “pistol-grade” shoot house, obstacle course and rappel tower. NASA’s Security Management and Safeguards Office funded the enhancements in order to improve ability to train the KSC security force and to support local, state and federal law enforcement agencies in Homeland Security.

  2. Live Fire Range Environmental Assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1993-08-01

    The Central Training Academy (CTA) is a DOE Headquarters Organization located in Albuquerque, New Mexico, with the mission to effectively and efficiently educate and train personnel involved in the protection of vital national security interests of DOE. The CTA Live Fire Range (LFR), where most of the firearms and tactical training occurs, is a complex separate from the main campus. The purpose of the proposed action is to expand the LFR to allow more options of implementing required training. The Department of Energy has prepared this Environmental Assessment (EA) for the proposed construction and operation of an expanded Live Firemore » Range Facility at the Central Training Academy in Albuquerque, New Mexico. Based on the analysis in the EA, DOE has determined that the proposed action is not a major Federal action significantly affecting the quality of the human environment, within the meaning of the National Environmental Policy Act (NEPA) of 1969. Therefore, the preparation of an environmental impact statement is not required and DOE is issuing this Finding of No Significant Impact (FONSI).« less

  3. Transfer of Timing Information from RGC to LGN Spike Trains

    NASA Astrophysics Data System (ADS)

    Teich, Malvin C.; Lowen, Steven B.; Saleh, Bahaa E. A.; Kaplan, Ehud

    1998-03-01

    We have studied the firing patterns of retinal ganglion cells (RGCs) and their target lateral geniculate nucleus (LGN) cells. We find that clusters of spikes in the RGC neural firing pattern appear at the LGN output essentially unchanged, while isolated RGC firing events are more likely to be eliminated; thus the LGN action-potential sequence is therefore not merely a randomly deleted version of the RGC spike train. Employing information-theoretic techniques we developed for point processes,(B. E. A. Saleh and M. C. Teich, Phys. Rev. Lett.) 58, 2656--2659 (1987). we are able to estimate the information efficiency of the LGN neuronal output --- the proportion of the variation in the LGN firing pattern that carries information about its associated RGC input. A suitably modified integrate-and-fire neural model reproduces both the enhanced clustering in the LGN data (which accounts for the increased coefficient of variation) and the measured value of information efficiency, as well as mimicking the results of other observed statistical measures. Reliable information transmission therefore coexists with fractal fluctuations, which appear in RGC and LGN firing patterns.(M. C. Teich, C. Heneghan, S. B. Lowen, T. Ozaki, and E. Kaplan, J. Opt. Soc. Am. A) 14, 529--546 (1997).

  4. Firefighters from Mayport Naval Station train at CCAFS

    NASA Technical Reports Server (NTRS)

    2000-01-01

    Firefighters in full gear wait to approach a burning simulated aircraft during training exercises at Cape Canaveral Air Force Station Pad 30. The firefighters are with the Fire and Emergency Services at the Naval Station Mayport, Fla.

  5. Training Guidelines: Bricks Operatives.

    ERIC Educational Resources Information Center

    Ceramics, Glass, and Mineral Products Industry Training Board, Harrow (England).

    This manual offers guidelines for training of personnel involved in the manufacture of bricks, including employment practices; handling and preparation of raw materials; making, drying, firing, sorting, packing, and loading of bricks. A major emphasis is placed on industrial safety. (MF)

  6. Nucleation sites of Ge nanoislands grown on pit-patterned Si substrate prepared by electron-beam lithography

    NASA Astrophysics Data System (ADS)

    Smagina, Zh. V.; Zinovyev, V. A.; Rudin, S. A.; Novikov, P. L.; Rodyakina, E. E.; Dvurechenskii, A. V.

    2018-04-01

    Regular pit-patterned Si(001) substrates were prepared by electron-beam lithography followed by plasma chemical etching. The geometry of the pits was controlled by varying the etching conditions and the electron-beam exposure duration. It was shown that the location of three-dimensional (3D) Ge nanoislands subsequently grown on the pit-patterned Si substrates depends on the shape of the pit bottom. In the case of pits having a sharp bottom, 3D Ge islands nucleate inside the pits. For pits with a wide flat bottom, the 3D Ge island nucleation takes place at the pit periphery. This effect is attributed to the strain relaxation depending not only on the initial pit shape, but also on its evolution during the Ge wetting layer deposition. It was shown by Monte Carlo simulations that in the case of a pit with a pointed bottom, the relaxation is most effective inside the pit, while for a pit with a wide bottom, the most relaxed area migrates during Ge deposition from the pit bottom to its edges, where 3D Ge islands nucleate.

  7. Prediction and perception of hazards in professional drivers: Does hazard perception skill differ between safe and less-safe fire-appliance drivers?

    PubMed

    Crundall, David; Kroll, Victoria

    2018-05-18

    Can hazard perception testing be useful for the emergency services? Previous research has found emergency response drivers' (ERDs) to perform better than controls, however these studies used clips of normal driving. In contrast, the current study filmed footage from a fire-appliance on blue-light training runs through Nottinghamshire, and endeavoured to discriminate between different groups of EDRs based on experience and collision risk. Thirty clips were selected to create two variants of the hazard perception test: a traditional push-button test requiring speeded-responses to hazards, and a prediction test that occludes at hazard onset and provides four possible outcomes for participants to choose between. Three groups of fire-appliance drivers (novices, low-risk experienced and high-risk experienced), and age-matched controls undertook both tests. The hazard perception test only discriminated between controls and all FA drivers, whereas the hazard prediction test was more sensitive, discriminating between high and low-risk experienced fire appliance drivers. Eye movement analyses suggest that the low-risk drivers were better at prioritising the hazardous precursors, leading to better predictive accuracy. These results pave the way for future assessment and training tools to supplement emergency response driver training, while supporting the growing literature that identifies hazard prediction as a more robust measure of driver safety than traditional hazard perception tests. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Martian Central Pit Craters

    NASA Technical Reports Server (NTRS)

    Hillman, E.; Barlow, N. G.

    2005-01-01

    Impact craters containing central pits are rare on the terrestrial planets but common on icy bodies. Mars is the exception among the terrestrial planets, where central pits are seen on crater floors ( floor pits ) as well as on top of central peaks ( summit pits ). Wood et al. [1] proposed that degassing of subsurface volatiles during crater formation produced central pits. Croft [2] argued instead that central pits might form during the impact of volatile-rich comets. Although central pits are seen in impact craters on icy moons such as Ganymede, they do show some significant differences from their martian counterparts: (a) only floor pits are seen on Ganymede, and (b) central pits begin to occur at crater diameters where the peak ring interior morphology begins to appear in terrestrial planet craters [3]. A study of craters containing central pits was conducted by Barlow and Bradley [4] using Viking imagery. They found that 28% of craters displaying an interior morphology on Mars contain central pits. Diameters of craters containing central pits ranged from 16 to 64 km. Barlow and Bradley noted that summit pit craters tended to be smaller than craters containing floor pits. They also noted a correlation of central pit craters with the proposed rings of large impact basins. They argued that basin ring formation fractured the martian crust and allowed subsurface volatiles to concentrate in these locations. They favored the model that degassing of the substrate during crater formation was responsible for central pit formation due to the preferential location of central pit craters along these basin rings.

  9. Improving Abnormality Detection on Chest Radiography Using Game-Like Reinforcement Mechanics.

    PubMed

    Chen, Po-Hao; Roth, Howard; Galperin-Aizenberg, Maya; Ruutiainen, Alexander T; Gefter, Warren; Cook, Tessa S

    2017-11-01

    Despite their increasing prevalence, online textbooks, question banks, and digital references focus primarily on explicit knowledge. Implicit skills such as abnormality detection require repeated practice on clinical service and have few digital substitutes. Using mechanics traditionally deployed in video games such as clearly defined goals, rapid-fire levels, and narrow time constraints may be an effective way to teach implicit skills. We created a freely available, online module to evaluate the ability of individuals to differentiate between normal and abnormal chest radiographs by implementing mechanics, including instantaneous feedback, rapid-fire cases, and 15-second timers. Volunteer subjects completed the modules and were separated based on formal experience with chest radiography. Performance between training and testing sets were measured for each group, and a survey was administered after each session. The module contained 74 cases and took approximately 20 minutes to complete. Thirty-two cases were normal radiographs and 56 cases were abnormal. Of the 60 volunteers recruited, 25 were "never trained" and 35 were "previously trained." "Never trained" users scored 21.9 out of 37 during training and 24.0 out of 37 during testing (59.1% vs 64.9%, P value <.001). "Previously trained" users scored 28.0 out of 37 during training and 28.3 out of 37 during testing phases (75.6% vs 76.4%, P value = .56). Survey results showed that 87% of all subjects agreed the module is an efficient way of learning, and 83% agreed the rapid-fire module is valuable for medical students. A gamified online module may improve the abnormality detection rates of novice interpreters of chest radiography, although experienced interpreters are less likely to derive similar benefits. Users reviewed the educational module favorably. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  10. 46 CFR 131.535 - Firefighting training and drills.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Firefighting training and drills. 131.535 Section 131... OPERATIONS Tests, Drills, and Inspections § 131.535 Firefighting training and drills. (a) A fire drill must... drill, nor immediately before or after the abandon-ship drill. If none can be held on schedule, because...

  11. 46 CFR 131.535 - Firefighting training and drills.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Firefighting training and drills. 131.535 Section 131... OPERATIONS Tests, Drills, and Inspections § 131.535 Firefighting training and drills. (a) A fire drill must... drill, nor immediately before or after the abandon-ship drill. If none can be held on schedule, because...

  12. 46 CFR 131.535 - Firefighting training and drills.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Firefighting training and drills. 131.535 Section 131... OPERATIONS Tests, Drills, and Inspections § 131.535 Firefighting training and drills. (a) A fire drill must... drill, nor immediately before or after the abandon-ship drill. If none can be held on schedule, because...

  13. 46 CFR 131.535 - Firefighting training and drills.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Firefighting training and drills. 131.535 Section 131... OPERATIONS Tests, Drills, and Inspections § 131.535 Firefighting training and drills. (a) A fire drill must... drill, nor immediately before or after the abandon-ship drill. If none can be held on schedule, because...

  14. 46 CFR 131.535 - Firefighting training and drills.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Firefighting training and drills. 131.535 Section 131... OPERATIONS Tests, Drills, and Inspections § 131.535 Firefighting training and drills. (a) A fire drill must... drill, nor immediately before or after the abandon-ship drill. If none can be held on schedule, because...

  15. Teaching Health and Safety: Preparing Staff for the Unexpected.

    ERIC Educational Resources Information Center

    Cronin, Greg

    1999-01-01

    Discusses methods for training camp counselors in safety standards. Safety awareness and camp wellness should be introduced during staff interviews. During precamp training, staff should complete a test in OSHA requirements, followed by role playing to expand staff's knowledge in each OSHA safety and health area. First aid training, fire safety,…

  16. Evoking prescribed spike times in stochastic neurons

    NASA Astrophysics Data System (ADS)

    Doose, Jens; Lindner, Benjamin

    2017-09-01

    Single cell stimulation in vivo is a powerful tool to investigate the properties of single neurons and their functionality in neural networks. We present a method to determine a cell-specific stimulus that reliably evokes a prescribed spike train with high temporal precision of action potentials. We test the performance of this stimulus in simulations for two different stochastic neuron models. For a broad range of parameters and a neuron firing with intermediate firing rates (20-40 Hz) the reliability in evoking the prescribed spike train is close to its theoretical maximum that is mainly determined by the level of intrinsic noise.

  17. Application of Rapid Prototyping to the Investment Casting of Test Hardware (MSFC Center Director's Discretionary Fund Final Report, Project No. 98-08)

    NASA Technical Reports Server (NTRS)

    Cooper, K. G.; Wells, D.

    2000-01-01

    Investment casting masters of a selected propulsion hardware component, a fuel pump housing, were rapid prototyped on the several processes in-house, along with the new Z-Corp process acquired through this project. Also, tensile samples were prototyped and cast using the same significant parameters. The models were then shelled in-house using a commercial grade zircon-based slurry and stucco technique. Next, the shelled models were fired and cast by our in-house foundry contractor (IITRI), with NASA-23, a commonly used test hardware metal. The cast models are compared by their surface finish and overall appearance (i.e., the occurrence of pitting, warping, etc.), as well as dimensional accuracy.

  18. Pb, Sr and Nd isotopic composition and trace element characteristics of coarse airborne particles collected with passive samplers

    NASA Astrophysics Data System (ADS)

    Hoàng-Hòa, Thi Bich; Stille, Peter; Dietze, Volker; Guéguen, Florence; Perrone, Thierry; Gieré, Reto

    2015-09-01

    Passive samplers for collection of coarse airborne particulate matter have been installed in and around the coal-mining town of Cam Pha, Quang Ninh Province (Vietnam). Analysis of Pb, Sr, and Nd isotope ratios and of major and trace element distribution patterns in atmospheric particulates collected at three stations allowed for the identification of four important dust components: (1) coal dust from an open-pit mine and fly ash particles from a coal-fired power station, (2) diesel soot, (3) traffic dust from metal, tire and pavement abrasion, and (4) limestone-derived dust. Outside of the coal-mining area, traffic-derived dust defines the atmospheric baseline composition of the studied environment.

  19. Lightweight engine containment. [Kevlar shielding

    NASA Technical Reports Server (NTRS)

    Weaver, A. T.

    1977-01-01

    Kevlar fabric styles and weaves were studied, as well as methods of application for advanced gas turbine engines. The Kevlar material was subjected to high speed impacts by simple projectiles fired from a rifle, as well as more complex shapes such as fan blades released from gas turbine rotors in a spin pit. Just contained data was developed for a variety of weave and/or application techniques, and a comparative containment weight efficiency was established for Kevlar containment applications. The data generated during these tests is being incorporated into an analytical design system so that blade containment trade-off studies between Kevlar and metal case engine structures can be made. Laboratory tests and engine environment tests were performed to determine the survivability of Kevlar in a gas turbine environment.

  20. Acquisition of Fire Safety Knowledge and Skills With Virtual Reality Simulation.

    PubMed

    Rossler, Kelly L; Sankaranarayanan, Ganesh; Duvall, Adrianne

    2018-05-25

    Prelicensure nursing students seeking to enter perioperative nursing need preparatory fire safety knowledge and skills training to participate as a member of an operating room (OR) team. This pilot study examined the effectiveness of the Virtual Electrosurgery Skill Trainer (VEST) on OR fire safety skills among prelicensure nursing students. An experimental pretest-posttest design was used in this study. Twenty nursing students were randomized to a control or an intervention group. Knowledge and skills acquisition of OR fire safety were assessed. There were no statistically significant findings in knowledge for either group. Fisher exact test demonstrated significant relationships between the skills performance criteria of following emergency procedures for a fire and demonstrating PASS (pull-aim-squeeze-sweep) technique (P = .001). Academic and hospital educators may consider incorporating virtual reality simulation to teach fire safety education or reinforce general fire safety practices to nursing students and novice nurses.

  1. Mapping of the minimal inorganic phosphate transporting unit of human PiT2 suggests a structure universal to PiT-related proteins from all kingdoms of life

    PubMed Central

    2011-01-01

    Background The inorganic (Pi) phosphate transporter (PiT) family comprises known and putative Na+- or H+-dependent Pi-transporting proteins with representatives from all kingdoms. The mammalian members are placed in the outer cell membranes and suggested to supply cells with Pi to maintain house-keeping functions. Alignment of protein sequences representing PiT family members from all kingdoms reveals the presence of conserved amino acids and that bacterial phosphate permeases and putative phosphate permeases from archaea lack substantial parts of the protein sequence when compared to the mammalian PiT family members. Besides being Na+-dependent Pi (NaPi) transporters, the mammalian PiT paralogs, PiT1 and PiT2, also are receptors for gamma-retroviruses. We have here exploited the dual-function of PiT1 and PiT2 to study the structure-function relationship of PiT proteins. Results We show that the human PiT2 histidine, H502, and the human PiT1 glutamate, E70, - both conserved in eukaryotic PiT family members - are critical for Pi transport function. Noticeably, human PiT2 H502 is located in the C-terminal PiT family signature sequence, and human PiT1 E70 is located in ProDom domains characteristic for all PiT family members. A human PiT2 truncation mutant, which consists of the predicted 10 transmembrane (TM) domain backbone without a large intracellular domain (human PiT2ΔR254-V483), was found to be a fully functional Pi transporter. Further truncation of the human PiT2 protein by additional removal of two predicted TM domains together with the large intracellular domain created a mutant that resembles a bacterial phosphate permease and an archaeal putative phosphate permease. This human PiT2 truncation mutant (human PiT2ΔL183-V483) did also support Pi transport albeit at very low levels. Conclusions The results suggest that the overall structure of the Pi-transporting unit of the PiT family proteins has remained unchanged during evolution. Moreover, in combination, our studies of the gene structure of the human PiT1 and PiT2 genes (SLC20A1 and SLC20A2, respectively) and alignment of protein sequences of PiT family members from all kingdoms, along with the studies of the dual functions of the human PiT paralogs show that these proteins are excellent as models for studying the evolution of a protein's structure-function relationship. PMID:21586110

  2. Mapping of the minimal inorganic phosphate transporting unit of human PiT2 suggests a structure universal to PiT-related proteins from all kingdoms of life.

    PubMed

    Bøttger, Pernille; Pedersen, Lene

    2011-05-17

    The inorganic (Pi) phosphate transporter (PiT) family comprises known and putative Na(+)- or H(+)-dependent Pi-transporting proteins with representatives from all kingdoms. The mammalian members are placed in the outer cell membranes and suggested to supply cells with Pi to maintain house-keeping functions. Alignment of protein sequences representing PiT family members from all kingdoms reveals the presence of conserved amino acids and that bacterial phosphate permeases and putative phosphate permeases from archaea lack substantial parts of the protein sequence when compared to the mammalian PiT family members. Besides being Na(+)-dependent P(i) (NaP(i)) transporters, the mammalian PiT paralogs, PiT1 and PiT2, also are receptors for gamma-retroviruses. We have here exploited the dual-function of PiT1 and PiT2 to study the structure-function relationship of PiT proteins. We show that the human PiT2 histidine, H(502), and the human PiT1 glutamate, E(70),--both conserved in eukaryotic PiT family members--are critical for P(i) transport function. Noticeably, human PiT2 H(502) is located in the C-terminal PiT family signature sequence, and human PiT1 E(70) is located in ProDom domains characteristic for all PiT family members.A human PiT2 truncation mutant, which consists of the predicted 10 transmembrane (TM) domain backbone without a large intracellular domain (human PiT2ΔR(254)-V(483)), was found to be a fully functional P(i) transporter. Further truncation of the human PiT2 protein by additional removal of two predicted TM domains together with the large intracellular domain created a mutant that resembles a bacterial phosphate permease and an archaeal putative phosphate permease. This human PiT2 truncation mutant (human PiT2ΔL(183)-V(483)) did also support P(i) transport albeit at very low levels. The results suggest that the overall structure of the P(i)-transporting unit of the PiT family proteins has remained unchanged during evolution. Moreover, in combination, our studies of the gene structure of the human PiT1 and PiT2 genes (SLC20A1 and SLC20A2, respectively) and alignment of protein sequences of PiT family members from all kingdoms, along with the studies of the dual functions of the human PiT paralogs show that these proteins are excellent as models for studying the evolution of a protein's structure-function relationship. © 2011 Bøttger and Pedersen; licensee BioMed Central Ltd.

  3. Confined space emergency response: assessing employer and fire department practices.

    PubMed

    Wilson, Michael P; Madison, Heather N; Healy, Stephen B

    2012-01-01

    An emergency response plan for industrial permit-required confined space entry is essential for employee safety and is legally required. Maintaining a trained confined space rescue team, however, is costly and technically challenging. Some employers turn to public fire departments to meet their emergency response requirements. The confined space emergency response practices of employers and fire departments have not been previously assessed. We present (1) federal data on the U.S. occurrence between 1992 and 2005 of confined space fatal incidents involving toxic and/or oxygen-deficient atmospheres; (2) survey data from 21 large companies on permit-required confined space emergency response practices; (3) data on fire department arrival times; and (4) estimates by 10 senior fire officers of fire department rescue times for confined space incidents. Between 1992 and 2005, 431 confined space incidents that met the case definition claimed 530 lives, or about 0.63% of the 84,446 all-cause U.S. occupational fatal injuries that occurred during this period. Eighty-seven (20%) incidents resulted in multiple fatalities. Twelve (57%) of 21 surveyed companies reported that they relied on the fire department for permit-required confined space emergency response. Median fire department arrival times were about 5 min for engines and 7 min for technical rescue units. Fire department confined space rescue time estimates ranged from 48 to 123 min and increased to 70 and 173 min when hazardous materials were present. The study illustrates that (1) confined space incidents represent a small but continuing source of fatal occupational injuries in the United States; (2) a sizeable portion of employers may be relying on public fire departments for permit-required confined space emergency response; and (3) in the event of a life-threatening emergency, fire departments usually are not able to effect a confined space rescue in a timely manner. We propose that the appropriate role for the fire department is to support a properly trained and equipped on-site rescue team and to provide advanced life support intervention following extrication and during ambulance transportation.

  4. An Operational Safety and Health Program.

    ERIC Educational Resources Information Center

    Uhorchak, Robert E.

    1983-01-01

    Describes safety/health program activities at Research Triangle Institute (North Carolina). These include: radioisotope/radiation and hazardous chemical/carcinogen use, training, monitoring, disposal; chemical waste management; air monitoring and analysis; medical program; fire safety/training, including emergency planning; Occupational Safety and…

  5. Response of selected plants to fire on white sands missile range, New Mexico

    Treesearch

    Kenneth G. Boykin

    2008-01-01

    Little was known about the ecology, impacts, effects, and history of fire related to manyplants and communities within White Sands Missile Range. I began by identifying the knownaspects and the gaps in knowledge for White Sands Missile Range. I analyzed existing dataavailable for the Installation taken from the Integrated Training...

  6. FOI and Fire at the MGM Grand.

    ERIC Educational Resources Information Center

    Thompson, William N.; Marie, Janice

    The fire at the MGM Grand Hotel in Las Vegas, Nevada, brought to light a lack of compliance with the freedom of information philosophy and its supporting statutes. Freedom of information means circulation of important information. However, at the Grand Hotel, the hotel staff had not been properly trained in disaster procedures, the escape…

  7. Oxygen Assessments Ensure Safer Medical Devices

    NASA Technical Reports Server (NTRS)

    2013-01-01

    A team at White Sands Test Facility developed a test method to evaluate fire hazards in oxygen-enriched environments. Wendell Hull and Associates, located in Las Cruces, New Mexico, entered a Space Act Agreement with NASA and now provides services including fire and explosion investigations, oxygen testing and training, and accident reconstruction and forensic engineering.

  8. Efforts to update firefighter safety zone guidelines

    Treesearch

    Bret Butler

    2009-01-01

    One of the most critical decisions made on wildland fires is the identification of suitable safety zones for firefighters during daily fire management operations. To be effective (timely, repeatable, and accurate), these decisions rely on good training and judgment, but also on clear, concise guidelines. This article is a summary of safety zone guidelines and the...

  9. Rifle Marksmanship Diagnostic and Training Guide

    DTIC Science & Technology

    2011-05-01

    there any techniques you use to help prepare Soldiers to transition to firing with aiming lights (PEQ-2 or PAQ -4) and night vision goggles (ARM 1)? If...firing skills with the PAQ -4? A‐5    15. Are there any other diagnostic techniques you use that we haven’t discussed? a. Think back on your

  10. KSC-00pp1443

    NASA Image and Video Library

    2000-09-14

    KENNEDY SPACE CENTER, FLA. -- A firefighter (right) holds a water hose in readiness as others enter a smoke-filled simulated aircraft. The activities are part of fire training exercises at Cape Canaveral Air Force Station Pad 30 for firefighters with Fire and Emergency Services at the Naval Station Mayport, Fla. The firefighters have already extinguished flames from the aircraft

  11. KSC00pp1443

    NASA Image and Video Library

    2000-09-14

    KENNEDY SPACE CENTER, FLA. -- A firefighter (right) holds a water hose in readiness as others enter a smoke-filled simulated aircraft. The activities are part of fire training exercises at Cape Canaveral Air Force Station Pad 30 for firefighters with Fire and Emergency Services at the Naval Station Mayport, Fla. The firefighters have already extinguished flames from the aircraft

  12. Spike-train spectra and network response functions for non-linear integrate-and-fire neurons.

    PubMed

    Richardson, Magnus J E

    2008-11-01

    Reduced models have long been used as a tool for the analysis of the complex activity taking place in neurons and their coupled networks. Recent advances in experimental and theoretical techniques have further demonstrated the usefulness of this approach. Despite the often gross simplification of the underlying biophysical properties, reduced models can still present significant difficulties in their analysis, with the majority of exact and perturbative results available only for the leaky integrate-and-fire model. Here an elementary numerical scheme is demonstrated which can be used to calculate a number of biologically important properties of the general class of non-linear integrate-and-fire models. Exact results for the first-passage-time density and spike-train spectrum are derived, as well as the linear response properties and emergent states of recurrent networks. Given that the exponential integrate-fire model has recently been shown to agree closely with the experimentally measured response of pyramidal cells, the methodology presented here promises to provide a convenient tool to facilitate the analysis of cortical-network dynamics.

  13. The three principles of action: a Pavlovian-instrumental transfer hypothesis

    PubMed Central

    Cartoni, Emilio; Puglisi-Allegra, Stefano; Baldassarre, Gianluca

    2013-01-01

    Pavlovian conditioned stimuli can influence instrumental responding, an effect called Pavlovian-instrumental transfer (PIT). During the last decade, PIT has been subdivided into two types: specific PIT and general PIT, each having its own neural substrates. Specific PIT happens when a conditioned stimulus (CS) associated with a reward enhances an instrumental response directed to the same reward. Under general PIT, instead, the CS enhances a response directed to a different reward. While important progress has been made into identifying the neural substrates, the function of specific and general PIT and how they interact with instrumental responses are still not clear. In the experimental paradigm that distinguishes specific and general PIT an effect of PIT inhibition has also been observed and is waiting for an explanation. Here we propose an hypothesis that links these three PIT effects (specific PIT, general PIT and PIT inhibition) to three aspects of action evaluation. These three aspects, which we call “principles of action”, are: context, efficacy, and utility. In goal-directed behavior, an agent has to evaluate if the context is suitable to accomplish the goal, the efficacy of his action in getting the goal, and the utility of the goal itself: we suggest that each of the three PIT effects is related to one of these aspects of action evaluation. In particular, we link specific PIT with the estimation of efficacy, general PIT with the evaluation of utility, and PIT inhibition with the adequacy of context. We also provide a latent cause Bayesian computational model that exemplifies this hypothesis. This hypothesis and the model provide a new framework and new predictions to advance knowledge about PIT functioning and its role in animal adaptation. PMID:24312025

  14. Employment of Direct Fire Systems during Offensive Operations

    DTIC Science & Technology

    1990-06-01

    problems, this criteria suffers from a lack of offensive direct fire planning as part 115 of the scheme of maneuver. Limited TTP discussion in the...these specific occurrences. Doctrine writers could develop TTP to do so. This problem could involve unit training practices. If units differentiate ...10 0 0 0 5 PURPOSE) 4. - IDENTIFIES DIRECT FIRE I 76 15 20 130 21 15 115 R&S PRIORITY (PIR/IR) 5. - IDENTIFIES ENGAGEMENT 1 5 10 0 25 16 0 0 PRIORITY

  15. Using modeling and rehearsal to teach fire safety to children with autism.

    PubMed

    Garcia, David; Dukes, Charles; Brady, Michael P; Scott, Jack; Wilson, Cynthia L

    2016-09-01

    We evaluated the efficacy of an instructional procedure to teach young children with autism to evacuate settings and notify an adult during a fire alarm. A multiple baseline design across children showed that an intervention that included modeling, rehearsal, and praise was effective in teaching fire safety skills. Safety skills generalized to novel settings and maintained during a 5-week follow-up in both training and generalization settings. © 2016 Society for the Experimental Analysis of Behavior.

  16. Lead absorption in indoor firing range users.

    PubMed Central

    Valway, S E; Martyny, J W; Miller, J R; Cook, M; Mangione, E J

    1989-01-01

    To determine if users of indoor firing ranges may be at risk from lead exposure, we studied a law enforcement trainee class during three months of firearms instruction. Blood lead levels were obtained before training and at four-week intervals during training. Air lead levels were measured three times during instruction. Blood lead levels rose from a pre-training mean of 0.31 mumol/L to 2.47 mumol/L. Mean air lead levels were above 2,000 micrograms/m3, more than 40 times the Occupational Safety and Health Administration's standard of 50 micrograms/m3. Cumulative exposure to lead and the change in blood lead were positively correlated. Control measures need to be studied to determine their efficacy in decreasing or eliminating this health risk. PMID:2751019

  17. A probability distribution model of tooth pits for evaluating time-varying mesh stiffness of pitting gears

    NASA Astrophysics Data System (ADS)

    Lei, Yaguo; Liu, Zongyao; Wang, Delong; Yang, Xiao; Liu, Huan; Lin, Jing

    2018-06-01

    Tooth damage often causes a reduction in gear mesh stiffness. Thus time-varying mesh stiffness (TVMS) can be treated as an indication of gear health conditions. This study is devoted to investigating the mesh stiffness variations of a pair of external spur gears with tooth pitting, and proposes a new model for describing tooth pitting based on probability distribution. In the model, considering the appearance and development process of tooth pitting, we model the pitting on the surface of spur gear teeth as a series of pits with a uniform distribution in the direction of tooth width and a normal distribution in the direction of tooth height, respectively. In addition, four pitting degrees, from no pitting to severe pitting, are modeled. Finally, influences of tooth pitting on TVMS are analyzed in details and the proposed model is validated by comparing with a finite element model. The comparison results show that the proposed model is effective for the TVMS evaluations of pitting gears.

  18. Effects of auditory radio interference on a fine, continuous, open motor skill.

    PubMed

    Lazar, J M; Koceja, D M; Morris, H H

    1995-06-01

    The effects of human speech on a fine, continuous, and open motor skill were examined. A tape of auditory human radio traffic was injected into a tank gunnery simulator during each training session for 4 wk. of training for 3 hr. a week. The dependent variables were identification time, fire time, kill time, systems errors, and acquisition errors. These were measured by the Unit Conduct Of Fire Trainer (UCOFT). The interference was interjected into the UCOFT Tank Table VIII gunnery test. A Solomon four-group design was used. A 2 x 2 analysis of variance was used to assess whether interference gunnery training resulted in improvements in interference posttest scores. During the first three weeks of training, the interference group committed 106% more systems errors and 75% more acquisition errors than the standard group. The interference training condition was associated with a significant improvement from pre- to posttest of 44% in over-all UCOFT scores; however, when examined on the posttest the standard training did not improve performance significantly over the same period. It was concluded that auditory radio interference degrades performance of this fine, continuous, open motor skill, and interference training appears to abate the effects of this degradation.

  19. Auto- and Crosscorrelograms for the Spike Response of Leaky Integrate-and-Fire Neurons with Slow Synapses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moreno-Bote, Ruben; Parga, Nestor; Center for Theoretical Neuroscience, Center for Neurobiology and Behavior, Columbia University, New York 10032-2695

    2006-01-20

    An analytical description of the response properties of simple but realistic neuron models in the presence of noise is still lacking. We determine completely up to the second order the firing statistics of a single and a pair of leaky integrate-and-fire neurons receiving some common slowly filtered white noise. In particular, the auto- and cross-correlation functions of the output spike trains of pairs of cells are obtained from an improvement of the adiabatic approximation introduced previously by Moreno-Bote and Parga [Phys. Rev. Lett. 92, 028102 (2004)]. These two functions define the firing variability and firing synchronization between neurons, and aremore » of much importance for understanding neuron communication.« less

  20. Compressed Natural Gas Vehicle Maintenance Facility Modification Handbook

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelly, K.; Melendez, M.; Gonzales, J.

    To ensure the safety of personnel and facilities, vehicle maintenance facilities are required by law and by guidelines of the National Fire Protection Association (NFPA) and the International Fire Code (IFC) to exhibit certain design features. They are also required to be fitted with certain fire protection equipment and devices because of the potential for fire or explosion in the event of fuel leakage or spills. All fuels have an explosion or fire potential if specific conditions are present. This handbook covers the primary elements that must be considered when developing a CNG vehicle maintenance facility design that will protectmore » against the ignition of natural gas releases. It also discusses specific protocols and training needed to ensure safety.« less

  1. Commonalities in Russian Military Operations in Urban Environments

    DTIC Science & Technology

    2003-06-06

    6th Army was the Russian 62nd Siberian Army commanded by Vasili I Chuikov. The 6th Siberian Army was demoralized and depleted after a year of warfare...Battle of Stalingrad pitted untrained Russian militia and civilians against a highly trained German Army. Predictably the Russians experienced...Pennsylvania: U.S. Army War College. Chuikov, Vasili I. 1964. The Battle for Stalingrad, Trans. by: Harold Silver, New York, New York: Holt, Rhinehart and

  2. Quantitative Risk Modeling of Fire on the International Space Station

    NASA Technical Reports Server (NTRS)

    Castillo, Theresa; Haught, Megan

    2014-01-01

    The International Space Station (ISS) Program has worked to prevent fire events and to mitigate their impacts should they occur. Hardware is designed to reduce sources of ignition, oxygen systems are designed to control leaking, flammable materials are prevented from flying to ISS whenever possible, the crew is trained in fire response, and fire response equipment improvements are sought out and funded. Fire prevention and mitigation are a top ISS Program priority - however, programmatic resources are limited; thus, risk trades are made to ensure an adequate level of safety is maintained onboard the ISS. In support of these risk trades, the ISS Probabilistic Risk Assessment (PRA) team has modeled the likelihood of fire occurring in the ISS pressurized cabin, a phenomenological event that has never before been probabilistically modeled in a microgravity environment. This paper will discuss the genesis of the ISS PRA fire model, its enhancement in collaboration with fire experts, and the results which have informed ISS programmatic decisions and will continue to be used throughout the life of the program.

  3. Strategic oil reserves catch fire too

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crull, A.W.

    The Federal strategic oil storage site at West Hackberry Dome in Louisiana caught fire in spite of DOE assurances that this is the safest way to store oil. Most of the oil was recovered, although confusion at the site aggravated the problem in getting the fire under control. DOE called the incident an industrial accident, but has not acknowledged the risks involved in all aspects of petroleum drilling or handling -- and the drastic limits of personnel able to handle resulting accidents. Inteviews with Boots and Coots, a team of fire fighters in Houston, provided the author with details ofmore » oil fires and ways to deal with them. The oil fire fighters point out that all energy source development and storage involves some risk and that steps should be taken to train personnel to deal with the negative aspects of petroleum.« less

  4. KSC-04pd1654

    NASA Image and Video Library

    2004-08-05

    KENNEDY SPACE CENTER, FLA. - At the ribbon cutting for the Enhanced Firing Range on Schwartz Rd. at Kennedy Space Center, Dave Saleeba (left with weapon) and Center Director Jim Kennedy (right, with weapon) practice firing on the new range. Saleeba is assistant administrator with the Office of Security Management and Safeguards at NASA Headquarters and was a guest speaker at the ceremony. NASA’s Federal Law Enforcement Training Academy’s firing range has been upgraded to include a “rifle-grade” shoot house, a portable, tactical “shoot-back” trailer for cover and concealment drills, automated running targets and a new classroom facility. They are added to the existing three firearms ranges, “pistol-grade” shoot house, obstacle course and rappel tower. NASA’s Security Management and Safeguards Office funded the enhancements in order to improve ability to train the KSC security force and to support local, state and federal law enforcement agencies in Homeland Security.

  5. KSC-04PD-1654

    NASA Technical Reports Server (NTRS)

    2004-01-01

    KENNEDY SPACE CENTER, FLA. At the ribbon cutting for the Enhanced Firing Range on Schwartz Rd. at Kennedy Space Center, Dave Saleeba (left with weapon) and Center Director Jim Kennedy (right, with weapon) practice firing on the new range. Saleeba is assistant administrator with the Office of Security Management and Safeguards at NASA Headquarters and was a guest speaker at the ceremony. NASAs Federal Law Enforcement Training Academys firing range has been upgraded to include a rifle-grade shoot house, a portable, tactical shoot-back trailer for cover and concealment drills, automated running targets and a new classroom facility. They are added to the existing three firearms ranges, pistol-grade shoot house, obstacle course and rappel tower. NASAs Security Management and Safeguards Office funded the enhancements in order to improve ability to train the KSC security force and to support local, state and federal law enforcement agencies in Homeland Security.

  6. KSC-2011-1492

    NASA Image and Video Library

    2011-02-18

    CAPE CANAVERAL, Fla. – Deputy Fire Chief Rick Anderson, left, Chief of Fire Training George Hoggard, and Assistant Chief of Fire Training David Seymour with NASA Kennedy Space Center Protective Services participated in the "National 9/11 Flag" stitching ceremony in the Debus Conference Facility at the Kennedy Space Center Visitor Complex in Florida. The contributions of NASA, Kennedy Space Center and the state of Florida were stitched into the fabric of the American Flag, which was recovered near ground zero following the World Trade Center attacks on Sept. 11, 2001. The "New York Says Thank You Foundation" is taking the flag on a cross-country journey to be restored to its original 13-stripe design using pieces of fabric from American flags destined for retirement in all 50 states. Once the flag is restored, it will become a permanent collection of the National September 11 Memorial Museum being built at the World Trade Center site. Photo credit: NASA/Kim Shiflett

  7. Occupational overpressure exposure of breachers and military personnel

    NASA Astrophysics Data System (ADS)

    Kamimori, G. H.; Reilly, L. A.; LaValle, C. R.; Olaghere Da Silva, U. B.

    2017-11-01

    Military and law enforcement personnel may be routinely and repetitively exposed to low-level blast (LLB) overpressure during training and in operations. This repeated exposure has been associated with symptoms similar to that reported for sports concussion. This study reports LLB exposure for various military and law enforcement sources in operational training environments. Peak overpressure and impulse data are presented from indoor breaching, outdoor breaching, shotgun door breaching, small arms discharge, and mortar and artillery fire missions. Data were collected using the Black Box Biometrics (B3) Blast Gauge sensors. In all cases, sensors were attached to the operators and, where possible, also statically mounted to walls or other fixed structures. Peak overpressures from below 1 psi (7 kPa) to over 12 psi (83 kPa) were recorded; all values reported are uncorrected for incidence angle to the blast exposure source. The results of these studies indicate that the current minimum safe distance calculations are often inaccurate for both indoor and outdoor breaching scenarios as true environmental exposure can consistently exceed the 4 psi (28 kPa) incident safe threshold prescribed by U.S. Army doctrine. While ballistic (shotgun) door breaching and small arms firing only expose the operator to low peak exposure levels, the sheer number of rounds fired during training may result in an excessive cumulative exposure. Mortar and artillery crew members received significantly different overpressure and impulse exposures based on their position (job) relative to the weapon. As both the artillery and mortar crews commonly fire hundreds of rounds during a single training session they are also likely to receive high cumulative exposures. These studies serve to provide the research community with estimates for typical operator exposure across a range of operational scenarios or in the discharge of various weapons systems.

  8. Risk management of emergency service vehicle crashes in the United States fire service: process, outputs, and recommendations.

    PubMed

    Bui, David P; Pollack Porter, Keshia; Griffin, Stephanie; French, Dustin D; Jung, Alesia M; Crothers, Stephen; Burgess, Jefferey L

    2017-11-17

    Emergency service vehicle crashes (ESVCs) are a leading cause of death in the United States fire service. Risk management (RM) is a proactive process for identifying occupational risks and reducing hazards and unwanted events through an iterative process of scoping hazards, risk assessment, and implementing controls. We describe the process, outputs, and lessons learned from the application of a proactive RM process to reduce ESVCs in US fire departments. Three fire departments representative of urban, suburban, and rural geographies, participated in a facilitated RM process delivered through focus groups and stakeholder discussion. Crash reports from department databases were reviewed to characterize the context, circumstances, hazards and risks of ESVCs. Identified risks were ranked using a risk matrix that considered risk likelihood and severity. Department-specific control measures were selected based on group consensus. Interviews, and focus groups were used to assess acceptability and utility of the RM process and perceived facilitators and barriers of implementation. Three to six RM meetings were conducted at each fire department. There were 7.4 crashes per 100 personnel in the urban department and 10.5 per 100 personnel in the suburban department; the rural department experienced zero crashes. All departments identified emergency response, backing, on scene struck by, driver distraction, vehicle/road visibility, and driver training as high or medium concerns. Additional high priority risks varied by department; the urban department prioritized turning and rear ending crashes; the suburban firefighters prioritized inclement weather/road environment and low visibility related crashes; and the rural volunteer fire department prioritized exiting station, vehicle failure, and inclement weather/road environment related incidents. Selected controls included new policies and standard operating procedures to reduce emergency response, cameras to enhance driver visibility while backing, and increased training frequency and enhanced training. The RM process was generally acceptable to department participants and considered useful. All departments reported that the focused and systematic analysis of crashes was particularly helpful. Implementation of controls was a commonly cited challenge. Proactive RM of ESVCs in three US fire departments was positively received and supported the establishment of interventions tailored to each department's needs and priorities.

  9. Firefighters from Mayport Naval Station train at CCAFS

    NASA Technical Reports Server (NTRS)

    2000-01-01

    A firefighter waits for his companions before tackling the flames on a simulated aircraft. Firefighters with Fire and Emergency Services at the Naval Station Mayport, Fla., are taking part in training exercises at Cape Canaveral Air Force Station Pad 30.

  10. NIR detection of pits and pit fragments in fresh cherries (abstract)

    USDA-ARS?s Scientific Manuscript database

    The feasibility of using near infrared (NIR) diffuse reflectance spectroscopy for the detection of pits and pit fragments in cherries was demonstrated. For detection of whole pits, 300 cherries were obtained locally and pits were removed from half. NIR reflectance spectra were obtained in triplicate...

  11. 7 CFR 52.779 - Freedom from pits.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Freedom from pits. 52.779 Section 52.779 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... Freedom from pits. (a) General. The factor of freedom from pits refers to the incidence of pits and pit...

  12. The effects of pitting on fatigue crack nucleation in 7075-T6 aluminum alloy

    NASA Technical Reports Server (NTRS)

    Ma, LI; Hoeppner, David W.

    1994-01-01

    A high-strength aluminum alloy, 7075-T6, was studied to quantitatively evaluate chemical pitting effects of its corrosion fatigue life. The study focused on pit nucleation, pit growth, and fatigue crack nucleation. Pitting corrosion fatigue experiments were conducted in 3.5 percent NaCl aqueous solution under constant amplitude sinusoidal loading at two frequencies, 5 and 20 Hz. Smooth and unnotched specimens were used in this investigation. A video recording system was developed to allow in situ observation of the surface changes of the specimens during testing. The results indicated that pitting corrosion considerably reduces the fatigue strength by accelerating fatigue crack nucleation. A metallographic examination was conducted on the specimens to evaluate the nature of corrosion pits. First, the actual shapes of the corrosion pits were evaluated by cross-sectioning the pits. Secondly, the relation between corrosion pits and microstructure was also investigated. Finally, the possibility of another corrosion mechanism that might be involved in pitting was explored in this investigation. The fractography of the tested specimens showed that corner corrosion pits were responsible for fatigue crack nucleation in the material due to the associated stress concentration. The pits exhibited variance of morphology. Fatigue life for the experimental conditions appeared to be strongly dependent on pitting kinetics and the crack nucleation stage.

  13. The role of BK-type Ca2+-dependent K+ channels in spike broadening during repetitive firing in rat hippocampal pyramidal cells

    PubMed Central

    Shao, Li-Rong; Halvorsrud, Ragnhild; Borg-Graham, Lyle; Storm, Johan F

    1999-01-01

    The role of large-conductance Ca2+-dependent K+ channels (BK-channels; also known as maxi-K- or slo-channels) in spike broadening during repetitive firing was studied in CA1 pyramidal cells, using sharp electrode intracellular recordings in rat hippocampal slices, and computer modelling. Trains of action potentials elicited by depolarizing current pulses showed a progressive, frequency-dependent spike broadening, reflecting a reduced rate of repolarization. During a 50 ms long 5 spike train, the spike duration increased by 63·6 ± 3·4% from the 1st to the 3rd spike. The amplitude of the fast after-hyperpolarization (fAHP) also rapidly declined during each train. Suppression of BK-channel activity with (a) the selective BK-channel blocker iberiotoxin (IbTX, 60 nM), (b) the non-peptidergic BK-channel blocker paxilline (2–10 μM), or (c) calcium-free medium, broadened the 1st spike to a similar degree (≈60%). BK-channel suppression also caused a similar change in spike waveform as observed during repetitive firing, and eliminated (occluded) most of the spike broadening during repetitive firing. Computer simulations using a reduced compartmental model with transient BK-channel current and 10 other active ionic currents, produced an activity-dependent spike broadening that was strongly reduced when the BK-channel inactivation mechanism was removed. These results, which are supported by recent voltage-clamp data, strongly suggest that in CA1 pyramidal cells, fast inactivation of a transient BK-channel current (ICT), substantially contributes to frequency-dependent spike broadening during repetitive firing. PMID:10562340

  14. Differences in the motor unit firing rates and amplitudes in relation to recruitment thresholds during submaximal contractions of the first dorsal interosseous between chronically resistance trained and physically active men.

    PubMed

    Sterczala, Adam J; Miller, Jonathan D; Trevino, Michael A; Dimmick, Hannah L; Herda, Trent J

    2018-02-26

    Previous investigations report no changes in motor unit (MU) firing rates during submaximal contractions following resistance training. These investigations did not account for MU recruitment or examine firing rates as a function of recruitment threshold (REC).Therefore, MU recruitment and firing rates in chronically resistance trained (RT) and physically active controls (CON) were examined. Surface electromyography signals were collected from the first dorsal interosseous (FDI) during isometric muscle actions at 40% and 70% maximal voluntary contraction (MVC). For each MU, force at REC, mean firing rate (MFR) during the steady force, and MU action potential amplitude (MUAPAMP) were analyzed. For each individual and contraction, the MFRs were linearly regressed against REC, whereas, exponential models were applied to the MFR vs. MUAPAMP and MUAPAMP vs. REC relationships with the y-intercepts and slopes (linear) and A and B terms (exponential) calculated. For the 40% MVC, the RT group had less negative slopes (p=0.001) and lower y-intercepts (p=0.006) of the MFR vs. REC relationships and lower B terms (p=0.011) of the MUAPAMP vs. REC relationships. There were no differences in either relationship between groups for the 70% MVC. During the 40% MVC, the RT had a smaller range of MFRs and MUAPAMPS in comparison to the CON, likely due to reduced MU recruitment. The RT had lower MFRs and recruitment during the 40% MVC that may indicate a leftward shift in the force-frequency relationship, and thus require less excitation to the motoneuron pool to match the same relative force.

  15. A Comparison of Computer-based and Instructor-led Training for Long-term Care Staff.

    ERIC Educational Resources Information Center

    Harrington, Susan S.; Walker, Bonnie L.

    2002-01-01

    Fire safety training was provided to long-term care staff by computer (n=47) or a print-based, instructor-led program (n=47). Compared to 47 controls, both treatment groups significantly increased knowledge. The computer-trained staff were enthusiastic about the learning method and expressed greater interest in additional safety topics. (SK)

  16. Fire Service Training. Immediate Care of the Burn Patient.

    ERIC Educational Resources Information Center

    North Carolina State Dept. of Community Colleges, Raleigh.

    Part of a series of instructional outlines intended for use in a training program for firemen with no previous formal training, this curriculum guide discusses the emergency treatment of thermal, chemical, and electrical burns. The topics covered are as follow: (1) evaluation of the degree and extent of the burn; (2) shock, its signs and…

  17. The effect of fatigue and training status on firefighter performance.

    PubMed

    Dennison, Katie J; Mullineaux, David R; Yates, James W; Abel, Mark G

    2012-04-01

    Firefighting is a strenuous occupation that requires optimal levels of physical fitness. The National Fire Protection Association suggests that firefighters should be allowed to exercise on duty to maintain adequate fitness levels. However, no research has addressed the effect of exercise-induced fatigue on subsequent fire ground performance. Therefore, the primary purpose of this study was to determine the effect that a single exercise session had on the performance of a simulated fire ground test (SFGT). Secondarily, this study sought to compare the effect of physical training status (i.e., trained vs. untrained firefighters) on the performance of an SFGT. Twelve trained (age: 31.8 ± 6.9 years; body mass index [BMI]: 27.7 ± 3.3 kg·m(-2); VO2peak: 45.6 ± 3.3 ml·kg(-1)·min(-1)) and 37 untrained (age: 31.0 ± 9.0 years; BMI: 31.3 ± 5.2 kg·m(-2); VO2peak: 40.2 ± 5.2 ml·kg(-1)·min(-1)) male career firefighters performed a baseline SFGT. The trained firefighters performed a second SFGT after an exercise session. Time to complete the SFGT, heart rate, and blood lactate were compared between baseline and exercise SFGT (EX-SFGT) conditions. In the trained firefighters, time to complete the SFGT (9.6% increase; p = 0.002) and heart rate (4.1% increase; p = 0.032) were greater during the EX-SFGT compared with baseline, with no difference in post-SFGT blood lactate (p = 0.841). The EX-SFGT time of the trained firefighters was faster than approximately 70% of the untrained firefighters' baseline SFGT time. In addition, the baseline SFGT time of the trained firefighters was faster than 81% of the untrained firefighters. This study demonstrated that on-duty exercise training reduced the work efficiency in firefighters. However, adaptations obtained through regular on-duty exercise training may limit decrements in work efficiency because of acute exercise fatigue and allow for superior work efficiency compared with not participating in a training program.

  18. Health Impacts of Climate Change-Induced Subzero Temperature Fires.

    PubMed

    Metallinou, Maria-Monika; Log, Torgrim

    2017-07-20

    General fire risk and the special risk related to cold climate cellulosic drying processes are outlined. Four recent subzero temperatures fires are studied with respect to health impacts: a wooden village fire, a single wood structure fire, a wildland urban interface (WUI) fire and a huge wildland fire. The health impacts range from stress related to loss of jobs, psychological effects of lost possessions, exposure to smoke and heat as well as immediate, or delayed, loss of lives. These four fires resulted in 32 fatalities, 385 persons hospitalized for shorter or longer periods, 104 structures lost and 1015 km² of wildland burned north of, and just south of, the Arctic Circle. It is shown that the combination of subzero temperature dry weather, strong winds, changing agricultural activities and declining snowpack may lead to previously anticipated threats to people and the environment. There are reasons to believe that these fires are a result of the ongoing climate changes. Risk impacts are discussed. Rural districts and/or vulnerable populations seem to be most affected. Training methods to identify and better monitor critical fire risk parameters are suggested to mitigate the health impacts of a possibly increasing number of such fires.

  19. Health Impacts of Climate Change-Induced Subzero Temperature Fires

    PubMed Central

    Metallinou, Maria-Monika; Log, Torgrim

    2017-01-01

    General fire risk and the special risk related to cold climate cellulosic drying processes are outlined. Four recent subzero temperatures fires are studied with respect to health impacts: a wooden village fire, a single wood structure fire, a wildland urban interface (WUI) fire and a huge wildland fire. The health impacts range from stress related to loss of jobs, psychological effects of lost possessions, exposure to smoke and heat as well as immediate, or delayed, loss of lives. These four fires resulted in 32 fatalities, 385 persons hospitalized for shorter or longer periods, 104 structures lost and 1015 km2 of wildland burned north of, and just south of, the Arctic Circle. It is shown that the combination of subzero temperature dry weather, strong winds, changing agricultural activities and declining snowpack may lead to previously anticipated threats to people and the environment. There are reasons to believe that these fires are a result of the ongoing climate changes. Risk impacts are discussed. Rural districts and/or vulnerable populations seem to be most affected. Training methods to identify and better monitor critical fire risk parameters are suggested to mitigate the health impacts of a possibly increasing number of such fires. PMID:28726752

  20. Dose-Dependent Dual Role of PIT-1 (POU1F1) in Somatolactotroph Cell Proliferation and Apoptosis

    PubMed Central

    Jullien, Nicolas; Roche, Catherine; Brue, Thierry; Figarella-Branger, Dominique; Graillon, Thomas; Barlier, Anne; Herman, Jean-Paul

    2015-01-01

    To test the role of wtPIT-1 (PITWT) or PIT-1 (R271W) (PIT271) in somatolactotroph cells, we established, using inducible lentiviral vectors, sublines of GH4C1 somatotroph cells that allow the blockade of the expression of endogenous PIT-1 and/or the expression of PITWT or PIT271, a dominant negative mutant of PIT-1 responsible for Combined Pituitary Hormone Deficiency in patients. Blocking expression of endogenous PIT-1 induced a marked decrease of cell proliferation. Overexpressing PITWT twofold led also to a dose-dependent decrease of cell proliferation that was accompanied by cell death. Expression of PIT271 induced a strong dose-dependent decrease of cell proliferation accompanied by a very pronounced cell death. These actions of PIT271 are independent of its interaction/competition with endogenous PIT-1, as they were unchanged when expression of endogenous PIT-1 was blocked. All these actions are specific for somatolactotroph cells, and could not be observed in heterologous cells. Cell death induced by PITWT or by PIT271 was accompanied by DNA fragmentation, but was not inhibited by inhibitors of caspases, autophagy or necrosis, suggesting that this cell death is a caspase-independent apoptosis. Altogether, our results indicate that under normal conditions PIT-1 is important for the maintenance of cell proliferation, while when expressed at supra-normal levels it induces cell death. Through this dual action, PIT-1 may play a role in the expansion/regression cycles of pituitary lactotroph population during and after lactation. Our results also demonstrate that the so-called “dominant-negative” action of PIT271 is independent of its competition with PIT-1 or a blockade of the actions of the latter, and are actions specific to this mutant variant of PIT-1. PMID:25822178

  1. Quantifying post-fire fallen trees using multi-temporal lidar

    NASA Astrophysics Data System (ADS)

    Bohlin, Inka; Olsson, Håkan; Bohlin, Jonas; Granström, Anders

    2017-12-01

    Massive tree-felling due to root damage is a common fire effect on burnt areas in Scandinavia, but has so far not been analyzed in detail. Here we explore if pre- and post-fire lidar data can be used to estimate the proportion of fallen trees. The study was carried out within a large (14,000 ha) area in central Sweden burnt in August 2014, where we had access to airborne lidar data from both 2011 and 2015. Three data-sets of predictor variables were tested: POST (post-fire lidar metrics), DIF (difference between post- and pre-fire lidar metrics) and combination of those two (POST_DIF). Fractional logistic regression was used to predict the proportion of fallen trees. Training data consisted of 61 plots, where the number of fallen and standing trees was calculated both in the field and with interpretation of drone images. The accuracy of the best model was tested based on 100 randomly selected validation plots with a size of 25 × 25 m. Our results showed that multi-temporal lidar together with field-collected training data can be used for quantifying post-fire tree felling over large areas. Several height-, density- and intensity metrics correlated with the proportion of fallen trees. The best model combined metrics from both datasets (POST_DIF), resulting in a RMSE of 0.11. Results were slightly poorer in the validation plots with RMSE of 0.18 using pixel size of 12.5 m and RMSE of 0.15 using pixel size of 6.25 m. Our model performed least well for stands that had been exposed to high-intensity crown fire. This was likely due to the low amount of echoes from the standing black tree skeletons. Wall-to-wall maps produced with this model can be used for landscape level analysis of fire effects and to explore the relationship between fallen trees and forest structure, soil type, fire intensity or topography.

  2. Measuring fire weather and forest inflammability

    Treesearch

    H. T. Gisborne

    1936-01-01

    In the measurement of fire weather and forest inflammability, now practiced regularly at more than 90 forest stations in northern Idaho and western Montana, it is necessary to use many methods that are peculiar to this work. Some of these methods are familiar to meteorologists, but few foresters have had any appreciable training in meteorology. Others are of such,...

  3. 46 CFR 27.209 - What are the requirements for training crews to respond to fires?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the engine room and effectively seal all natural openings to the space to prevent leakage of the.... (3) Reporting inoperative alarm systems and fire-detection systems. (4) Putting on a fireman's outfit...) Testing of all alarm and detection systems; and (4) Putting on protective clothing (by at least one person...

  4. Firefighter Math - a web-based learning tool

    Treesearch

    Dan Jimenez

    2010-01-01

    Firefighter Math is a web based interactive resource that was developed to help prepare wildland fire personnel for math based training courses. The website can also be used as a refresher for fire calculations including slope, flame length, relative humidity, flow rates, unit conversion, etc. The website is designed to start with basic math refresher skills and...

  5. Fire Protection Specialist, Blocks IV and V, 17-3. Military Curriculum Materials for Vocational and Technical Education.

    ERIC Educational Resources Information Center

    Ohio State Univ., Columbus. National Center for Research in Vocational Education.

    This military-developed text contains the fourth and fifth blocks of a five-block course for use in training fire protection specialists. Covered in the individual volumes are the following topics: structural firefighting (operation and maintenance of hydrants, emergency response activities, structural pumpers, vehicle positioning and relay, hose…

  6. Rain Erosion Studies of Sapphire, Aluminum Oxynitride, Spinel, Lanthana- Doped Yttria, and TAF Glass

    DTIC Science & Technology

    1990-07-01

    small , there is little change in average scatter for any material in any test. CONCLUSIONS AND DISCUSSION The principal conclusions are 1. ALON...20 Sample broke erosion damage 10 Slight pitting, 20 No change erosion damage 15 Pitting, cratering, 20 Small surface pits erosion damage 15 Pitting...Sample broke 10 No damage 15 Sample pitted, small edge fracture 15 Slight pitting, 1 crater, 20 Sample pitted, erosion damage small edge fracture 15 SUght

  7. Hazardous materials training : DOT and private sector initiatives generally complement each other

    DOT National Transportation Integrated Search

    2000-07-01

    Every day, trucks and trains transport over 770,000 shipments of hazardous materials across the United States. Accidents involving these materials-spills, fires, and explosions-cost the United States over $459 million annually and can have serious co...

  8. Impacts of prescribed fire on ecosystem C and N cycles at Fort Benning Installation, Georgia

    NASA Astrophysics Data System (ADS)

    Zhao, S.; Liu, S.; Tieszen, L.

    2007-12-01

    A critical challenge for the land managers at military installation is to maintain the ecological sustainability of natural resources while meeting the needs of military training. Prescribed ground fire as a land management practice has been used to remove the ground layer plants at Fort Benning for two purposes: to facilitate access for military training, and to maintain and restore fire-adapted longleaf pine communities that are critical habitat for the federally endangered red-cockaded woodpecker (Picoides borealis). Nevertheless, the impacts of prescribed fire on ecosystem processes and health are not well-understood and quantified at the plot to regional scales. Frequent fire may result in ecosystem nitrogen (N) deficiency due to repeated N loss through combustion, volatilization, and leaching, threatening ecosystem sustainability at Fort Benning. On the other hand, N loss may be offset by enhanced symbiotic N2 fixation since fire favors herbaceous legumes by scarifying legume seeds and stimulating germination. Quantifying the impacts of prescribed fire on ecosystem carbon (C) and N cycles is further complicated by interactions and feedbacks among burning, nitrogen inputs, other land use practices (e.g. tree thinning or clear-cutting), and soil properties. In this study, we used the Erosion-Deposition-Carbon Model (EDCM), a process-based biogeochemical model, to simulate C and N dynamic at Fort Benning under different combinations of fire frequency, fire intensity, nitrogen deposition, legume nitrogen input, forest harvesting, and soil sand content. Model simulations indicated that prescribed fire led to nitrogen losses from ecosystems at Fort Benning, especially with high intensity and high frequency fires. Forest harvesting further intensified ecosystem nitrogen limitation, leading to reduced biophysical potential of C sequestration. The adverse impacts of prescribed fire and forest harvesting on C and N cycles were much higher in more sandy soil than in less sandy soil. N inputs from nitrogen deposition and legume N fixation helped replenish N losses to some extent. However, N losses due to fire and harvesting were not balanced or exceeded under current atmospheric N deposition and legume N input rates, suggesting additional N input (e.g., fertilization) may be needed to maintain the sustainability of current ecosystem states and management practices at Fort Benning.

  9. Was Hawan Designed to Fight Anxiety-Scientific Evidences?

    PubMed

    Romana, R K; Sharma, A; Gupta, V; Kaur, R; Kumar, S; Bansal, P

    2017-01-06

    Anxiety is a psychiatric disorder with unknown neurobiology; however, neurotransmitters like gamma-amino butyric acid, norepinephrine and serotonin (5-HT) play crucial roles in mediating anxiety. Present drug modules pose dependence risk to the patient; hence, there is a great need to develop complementary therapies to fight this disorder. Aromatherapy has also been employed in ancient times for a number of mental disorders. Mahamrituanjay Mantra, Om triambkum yajamahe, sughandhim puushtivardhanam, urvarukmev vandhanaat, mrityu mokshay mamritaat!!!!, the part of veda enlightens that aroma gives rise to good health (sughandhim puushtivardhanam). Hawan is a religious practice recommended for mental peace. Hawan is a process in which special herbs are offered in the fire of medicinal woods ignited in a specially designed fire pit. Analysis of literature demonstrates that the components of Hawan are having a number of volatile oils that are specifically useful for prevention and treatment of anxiety through some mechanism of action. Due to high temperature of fire, the vapors of these oils from herbs enter into the central nervous system through nasal route. As per modern science and ancient texts on medicine, nasal drug delivery systems are the best for the diseases related to brain and head. The routine of performing Hawan might keep the threshold value of the therapeutic components in the body and help in preventing anxiety. In the present manuscript, authors highlight and integrate the modern and ancient concepts for treatment and prevention of anxiety through scientific evidences.

  10. The fire ant wars. Nature and science in the pesticide controversies of the late twentieth century.

    PubMed

    Buhs, Joshua Blu

    2002-09-01

    This essay uses an approach borrowed from environmental history to investigate the interaction of science and nature in a late twentieth-century controversy. This debate, over the proper response to fire ants that had been imported into the American South accidentally and then spread across the region, pitted Rachel Carson and loosely federated groups of conservationists, scientists, and citizens against the U.S. Department of Agriculture. The analysis falls into three sections: an examination of the natural history of the ants; an examination of the views of the competing factions; and an examination of how those views, transformed into action, affected the natural world. Both sides saw the ants in terms of a constellation of beliefs about the relationship between nature, science, and democracy. As various ideas were put into play, they interacted with the natural history of the insects in unexpected ways--and with consequences for the cultural authority of the antagonists. Combining insights from the history of science and environmental history helps explain how scientists gain and lose cultural authority and, more fundamentally, allows for an examination of how nature can be integrated into the history of science.

  11. Phosphate (Pi)-regulated heterodimerization of the high-affinity sodium-dependent Pi transporters PiT1/Slc20a1 and PiT2/Slc20a2 underlies extracellular Pi sensing independently of Pi uptake.

    PubMed

    Bon, Nina; Couasnay, Greig; Bourgine, Annabelle; Sourice, Sophie; Beck-Cormier, Sarah; Guicheux, Jérôme; Beck, Laurent

    2018-02-09

    Extracellular phosphate (P i ) can act as a signaling molecule that directly alters gene expression and cellular physiology. The ability of cells or organisms to detect changes in extracellular P i levels implies the existence of a P i -sensing mechanism that signals to the body or individual cell. However, unlike in prokaryotes, yeasts, and plants, the molecular players involved in P i sensing in mammals remain unknown. In this study, we investigated the involvement of the high-affinity, sodium-dependent P i transporters PiT1 and PiT2 in mediating P i signaling in skeletal cells. We found that deletion of PiT1 or PiT2 blunted the P i -dependent ERK1/2-mediated phosphorylation and subsequent gene up-regulation of the mineralization inhibitors matrix Gla protein and osteopontin. This result suggested that both PiTs are necessary for P i signaling. Moreover, the ERK1/2 phosphorylation could be rescued by overexpressing P i transport-deficient PiT mutants. Using cross-linking and bioluminescence resonance energy transfer approaches, we found that PiT1 and PiT2 form high-abundance homodimers and P i -regulated low-abundance heterodimers. Interestingly, in the absence of sodium-dependent P i transport activity, the PiT1-PiT2 heterodimerization was still regulated by extracellular P i levels. Of note, when two putative P i -binding residues, Ser-128 (in PiT1) and Ser-113 (in PiT2), were substituted with alanine, the PiT1-PiT2 heterodimerization was no longer regulated by extracellular P i These observations suggested that P i binding rather than P i uptake may be the key factor in mediating P i signaling through the PiT proteins. Taken together, these results demonstrate that P i -regulated PiT1-PiT2 heterodimerization mediates P i sensing independently of P i uptake. © 2018 by The American Society for Biochemistry and Molecular Biology, Inc.

  12. Dual mode warhead

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Obrsky, J.; Alexander, A.A.; Griffen, O.H.

    1980-12-31

    A dual mode warhead is provided for use against both soft and hard targets and capable of sensing which type of target has been struck comprising a casing made of a ductile material containing an explosive charge and a fuze assembly. The ductile warhead casing will mushroom and later split upon striking a hard target while still confining the explosive. Proper ductility and confinement are necessary for fuze sensing. The fuze assembly contains a pair of parallel firing trains, one initiated only by high and one by low impact deceleration. The firing train actuated by low impact deceleration contains amore » pyrotechnic delay to allow penetration of soft targets.« less

  13. Analysis of the bacterial community in aged and aging pit mud of Chinese Luzhou-flavour liquor by combined PCR-DGGE and quantitative PCR assay.

    PubMed

    Liang, Huipeng; Li, Wenfang; Luo, Qingchun; Liu, Chaolan; Wu, Zhengyun; Zhang, Wenxue

    2015-10-01

    The community structure of bacteria in aged and aging pit mud, which was judged according to their sensory and physicochemical characteristics, was analysed using polymerase chain reaction denaturing gradient gel electrophoresis (PCR-DGGE) and quantitative real-time PCR (qPCR). The phyla Firmicutes, Actinobacteria, Proteobacteria, Synergistetes and Unclassified Bacteria were detected and the fermentative Firmicutes was predominant in both types of pit mud in the PCR-DGGE analysis. Among Firmicutes, Clostridiales was dominant in aged pit mud while Bacillales and Lactobacillales were dominant in aging pit mud. The diversity of bacterial communities in aged pit mud was higher than that in aging pit mud. In the qPCR analysis the abundance of Clostridium IV in aged pit mud was higher than that in aging pit mud and there were significant differences in the quantity of Clostridium IV between aged and aging pit mud of the same cellar (P < 0.05). There were some significant differences in the microbial community structure between aged and aging pit mud. The differences in the quantity of Clostridium IV might be involved in the distinction that the aged pit mud has a strong aroma while the aging pit mud does not. © 2014 Society of Chemical Industry.

  14. Structure and function of bordered pits: new discoveries and impacts on whole-plant hydraulic function.

    PubMed

    Choat, Brendan; Cobb, Alexander R; Jansen, Steven

    2008-01-01

    Bordered pits are cavities in the lignified cell walls of xylem conduits (vessels and tracheids) that are essential components in the water-transport system of higher plants. The pit membrane, which lies in the center of each pit, allows water to pass between xylem conduits but limits the spread of embolism and vascular pathogens in the xylem. Averaged across a wide range of species, pits account for > 50% of total xylem hydraulic resistance, indicating that they are an important factor in the overall hydraulic efficiency of plants. The structure of pits varies dramatically across species, with large differences evident in the porosity and thickness of pit membranes. Because greater porosity reduces hydraulic resistance but increases vulnerability to embolism, differences in pit structure are expected to correlate with trade-offs between efficiency and safety of water transport. However, trade-offs in hydraulic function are influenced both by pit-level differences in structure (e.g. average porosity of pit membranes) and by tissue-level changes in conduit allometry (average length, diameter) and the total surface area of pit membranes that connects vessels. In this review we address the impact of variation in pit structure on water transport in plants from the level of individual pits to the whole plant.

  15. KSC-2014-2775

    NASA Image and Video Library

    2014-04-29

    CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, agency helicopter pilots ensure all is clear before taking off during a training exercise. Helicopter pilot Bill Martin, a URS Federal Technical Services in the agency's Aircraft Operations, is seen in the front seat. Behind Martin on the left, is Mark Huetter, of Chenega Security & Support Solutions. Martin serves as assistant chief of Training for the center's Fire Rescue Department. The activity taking place in Kennedy's Launch Complex 39 turn-basin parking lot was only one of several drills. It was part of a new training program that was developed by Kennedy's Fire Rescue department along with NASA Aircraft Operations to sharpen the skills needed to help rescue personnel learn how to collaborate with helicopter pilots in taking injured patients to hospitals as quickly as possible. Photo credit: NASA/Dan Casper

  16. Major incidents in Kenya: the case for emergency services development and training.

    PubMed

    Wachira, Benjamin W; Smith, Wayne

    2013-04-01

    Kenya's major incidents profile is dominated by droughts, floods, fires, terrorism, poisoning, collapsed buildings, accidents in the transport sector and disease/epidemics. With no integrated emergency services and a lack of resources, many incidents in Kenya escalate to such an extent that they become major incidents. Lack of specific training of emergency services personnel to respond to major incidents, poor coordination of major incident management activities, and a lack of standard operational procedures and emergency operation plans have all been shown to expose victims to increased morbidity and mortality. This report provides a review of some of the major incidents in Kenya for the period 2000-2012, with the hope of highlighting the importance of developing an integrated and well-trained Ambulance and Fire and Rescue service appropriate for the local health care system.

  17. PitScan: Computer-Assisted Feature Detection

    NASA Astrophysics Data System (ADS)

    Wagner, R. V.; Robinson, M. S.

    2018-04-01

    We developed PitScan to assist in searching the very large LROC image dataset for pits — unusual <200m wide vertical-walled holes in the Moon's surface. PitScan reduces analysts' workload by pre-filtering images to identify possible pits.

  18. Quantitative Correlation of 7B04 Aluminum Alloys Pitting Corrosion Morphology Characteristics with Stress Concentration Factor

    NASA Astrophysics Data System (ADS)

    Liu, Zhiguo; Yan, Guangyao; Mu, Zhitao; Li, Xudong

    2018-01-01

    The accelerated pitting corrosion test of 7B04 aluminum alloy specimen was carried out according to the spectrum which simulated airport environment, and the corresponding pitting corrosion damage was obtained and was defined through three parameters A and B and C which respectively denoted the corrosion pit surface length and width and corrosion pit depth. The ratio between three parameters could determine the morphology characteristics of corrosion pits. On this basis the stress concentration factor of typical corrosion pit morphology under certain load conditions was quantitatively analyzed. The research shows that the corrosion pits gradually incline to be ellipse in surface and moderate in depth, and most value of B/A and C/A lies in 1 between 4 and few maximum exceeds 4; The stress concentration factor Kf of corrosion pits is obviously affected by the its morphology, the value of Kf increases with corrosion pits depth increasement under certain corrosion pits surface geometry. Also, the value of Kf decreases with surface width increasement under certain corrosion pits depth. The research conclusion can set theory basis for corrosion fatigue life analysis of aircraft aluminum alloy structure.

  19. Effects of an ethanol-paired CS on responding for ethanol and food: Comparisons with a stimulus in a Truly-Random-Control group and to a food-paired CS on responding for food.

    PubMed

    Lamb, R J; Ginsburg, Brett C; Schindler, Charles W

    2016-12-01

    Motivational increases due to exposure to alcohol-paired Conditioned Stimuli (CS) are central to some accounts of alcoholism. However, few studies isolate a stimulus's function as a CS from its other potential functions. Pavlovian-Instrumental-Transfer (PIT) procedures isolate a stimulus's function as a CS from its other functions. Though there are several relevant studies using PIT, knowledge gaps exist. Particularly, it is not clear that an alcohol-paired CS will increase alcohol seeking compared to the same stimulus in a Truly-Random-Control group, nor whether such increases are specific to alcohol seeking. To address these knowledge gaps in Experiment 1, rats responded for ethanol (0.1 ml 8% w/v) under an RI 30-sec schedule, then the lever was removed and half the rats had ethanol delivered during occasional 120-sec light presentations, while the remainder had ethanol and the light presented under independent RT schedules. Later the lever was returned and the light was presented during responding in extinction (PIT test). Following this test, levers were again removed and the light was presented without ethanol (light extinction), following again by a PIT test. Responding in the two groups during light presentations did not differ in either PIT test. Experiment 2 repeated Experiment 1 using food instead of ethanol. In Experiment 2, responding during light presentations increased in the paired group. In Experiment 3, rats were trained on a concurrent FR schedule of food and ethanol delivery. Ethanol was delivered following 5 responses and the response requirement for food adjusted so that similar numbers of food and ethanol deliveries were obtained. Subsequently, rats underwent conditioning, control and testing procedures identical to those in Experiment 1. In Experiment 3, the ethanol-paired CS increased ethanol-responding, but not food-responding. These results are most easily interpreted as changes in responding resulting from CS-elicited behavior rather than motivational changes. This interpretation is more compatible with some descriptions of the role of an alcohol-paired CS in alcoholism than others. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Structures of Bordered Pits Potentially Contributing to Isolation of a Refilled Vessel from Negative Xylem Pressure in Stems of Morus australis Poir.: Testing of the Pit Membrane Osmosis and Pit Valve Hypotheses.

    PubMed

    Ooeda, Hiroki; Terashima, Ichiro; Taneda, Haruhiko

    2017-02-01

    Two hypotheses have been proposed to explain the mechanism preventing the refilling vessel water from being drained to the neighboring functional vessels under negative pressure. The pit membrane osmosis hypothesis proposes that the xylem parenchyma cells release polysaccharides that are impermeable to the intervessel pit membranes into the refilling vessel; this osmotically counteracts the negative pressure, thereby allowing the vessel to refill. The pit valve hypothesis proposes that gas trapped within intervessel bordered pits isolates the refilling vessel water from the surrounding functional vessels. Here, using the single-vessel method, we assessed these hypotheses in shoots of mulberry (Morus australis Poir.). First, we confirmed the occurrence of xylem refilling under negative pressure in the potted mulberry saplings. To examine the pit membrane osmosis hypothesis, we estimated the semi-permeability of pit membranes for molecules of various sizes and found that the pit membranes were not semi-permeable to polyethylene glycol of molecular mass <20,000. For the pit valve hypothesis, we formed pit valves in the intervessel pits in the short stem segments and measured the maximum liquid pressure up to which gases in bordered pits were retained. The threshold pressure ranged from 0.025 to 0.10 MPa. These values matched the theoretical value calculated from the geometry of the pit chamber (0.0692-0.101 MPa). Our results suggest that gas in the pits is retained by surface tension, even under substantial positive pressure to resolve gases in the refilling vessel, whereas the molecule size required for the pit membrane osmosis mechanism in mulberry would be unrealistically large. © The Author 2016. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists. All rights reserved. For permissions, please email: journals.permissions@oup.com.

Top