Recovery Act: Oxy-Combustion Techology Development for Industrial-Scale Boiler Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levasseur, Armand
2014-04-30
Alstom Power Inc. (Alstom), under U.S. DOE/NETL Cooperative Agreement No. DE-NT0005290, is conducting a development program to generate detailed technical information needed for application of oxy-combustion technology. The program is designed to provide the necessary information and understanding for the next step of large-scale commercial demonstration of oxy combustion in tangentially fired boilers and to accelerate the commercialization of this technology. The main project objectives include: • Design and develop an innovative oxyfuel system for existing tangentially-fired boiler units that minimizes overall capital investment and operating costs. • Evaluate performance of oxyfuel tangentially fired boiler systems in pilot scale testsmore » at Alstom’s 15 MWth tangentially fired Boiler Simulation Facility (BSF). • Address technical gaps for the design of oxyfuel commercial utility boilers by focused testing and improvement of engineering and simulation tools. • Develop the design, performance and costs for a demonstration scale oxyfuel boiler and auxiliary systems. • Develop the design and costs for both industrial and utility commercial scale reference oxyfuel boilers and auxiliary systems that are optimized for overall plant performance and cost. • Define key design considerations and develop general guidelines for application of results to utility and different industrial applications. The project was initiated in October 2008 and the scope extended in 2010 under an ARRA award. The project completion date was April 30, 2014. Central to the project is 15 MWth testing in the BSF, which provided in-depth understanding of oxy-combustion under boiler conditions, detailed data for improvement of design tools, and key information for application to commercial scale oxy-fired boiler design. Eight comprehensive 15 MWth oxy-fired test campaigns were performed with different coals, providing detailed data on combustion, emissions, and thermal behavior over a matrix of fuels, oxyprocess variables and boiler design parameters. Significant improvement of CFD modeling tools and validation against 15 MWth experimental data has been completed. Oxy-boiler demonstration and large reference designs have been developed, supported with the information and knowledge gained from the 15 MWth testing. The results from the 15 MWth testing in the BSF and complimentary bench-scale testing are addressed in this volume (Volume II) of the final report. The results of the modeling efforts (Volume III) and the oxy boiler design efforts (Volume IV) are reported in separate volumes.« less
APPLICATION OF REBURNING TO COAL-FIRED INDUSTRIAL BOILERS IN TAIWAN
The paper gives an overview of the characteristics of coal-fired industrial boilers in Taiwan and projections of the cost and performance data for retrofitting several boilers with reburning. The impacts of reburning fuel type on the reburning system design and cost effectivenes...
COST OF SELECTIVE CATALYTIC REDUCTION (SCR) APPLICATION FOR NOX CONTROL ON COAL-FIRED BOILERS
The report provides a methodology for estimating budgetary costs associated with retrofit applications of selective catalytic reduction (SCR) technology on coal-fired boilers. SCR is a postcombustion nitrogen oxides (NOx) control technology capable of providing NOx reductions >90...
COST OF SELECTIVE CATALYTIC REDUCTION (SCR) APPLICATION FOR NOX CONTROL ON COAL-FIRED BOILERS
The report provides a methodology for estimating budgetary costs associ-ated with retrofit applications of selec-tive catalytic reduction (SCR) technology on coal-fired boilers. SCR is a post-combustion nitrogen oxides (NOX) con-trol technology capable of providing NOX reductions...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sommer, T.; Melick, T.; Morrison, D.
The objective of this DOE sponsored project was to successfully fire coal-water slurry in a fire-tube boiler that was designed for oil/gas firing and establish a data base that will be relevant to a large number of existing installations. Firing slurry in a fire-tube configuration is a very demanding application because of the extremely high heat release rates and the correspondingly low furnace volume where combustion can be completed. Recognizing that combustion efficiency is the major obstacle when firing slurry in a fire-tube boiler, the program was focused on innovative approaches for improving carbon burnout without major modifications to themore » boiler. The boiler system was successfully designed and operated to fire coal-water slurry for extended periods of time with few slurry related operational problems. The host facility was a 3.8 million Btu/hr Cleaver-Brooks fire-tube boiler located on the University of Alabama Campus. A slurry atomizer was designed that provided outstanding atomization and was not susceptible to pluggage. The boiler was operated for over 1000 hours and 12 shipments of slurry were delivered. The new equipment engineered for the coal-water slurry system consisted of the following: combustion air and slurry heaters; cyclone; baghouse; fly ash reinjection system; new control system; air compressor; CWS/gas burner and gas valve train; and storage tank and slurry handling system.« less
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Applicability. The provisions of this section shall apply to each owner or operator of the fossil fuel-fired... the fossil fuel-fired, steam-generating equipment at the NGS, or the auxiliary steam boilers at the... of fires in the boiler with fuel oil, to the time when the electrostatic precipitator is sufficiently...
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Applicability. The provisions of this section shall apply to each owner or operator of the fossil fuel-fired... the fossil fuel-fired, steam-generating equipment at the NGS, or the auxiliary steam boilers at the... of fires in the boiler with fuel oil, to the time when the electrostatic precipitator is sufficiently...
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Applicability. The provisions of this section shall apply to each owner or operator of the fossil fuel-fired... the fossil fuel-fired, steam-generating equipment at the NGS, or the auxiliary steam boilers at the... of fires in the boiler with fuel oil, to the time when the electrostatic precipitator is sufficiently...
The report reviews information and estimated costs on 15 emissioncontrol technology categories applicable to existing coal-fired electric utility boilers. he categories include passive controls such as least emission dispatching, conventional processes, and emerging technologies ...
Coal-Burning Technologies Applicable to Air Force Central Heating Plants
1989-12-01
8 3. DESCRIPTION OF REPLACEMENT OR EXPANSION TECHNOLOGIES ........ 9 3.1.1 Shell (Fire- Tube ) Boilers ........... 9...3.1.2 Water- Tube Boilers .*.*........***.... 10 3.1.3 Packaged vs Field-Erected Construction ...... 11 3.2 STOKER FIRING ...... .. 11 3.2.1 Description...FIGURES 4 Figure Pg 1 Schematic diagram of a typical scotch shell boiler: wet-back, three-pass design ..~............... 9 2 Commnon tube patterns for
Accomplishments of the American-Polish program for elimination of low emissions in Krakow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Butcher, T.A.; Pierce, B.
1998-12-31
Since 1990 the US Department of Energy (DOE) has been involved in a program aimed at reducing air pollution caused by small, coal-fired sources in Poland. The activity is focused on the city of Cracow, Poland with the intention that results will be applicable and extendable to the entire region. The effort under this program has been focused into 5 main areas of interest as follows: (1) energy conservation and extension of central station district heating; (2) replacement of coal- and coke-fired boilers with natural gas-fired boilers; (3) replacement of coal-fired home stoves with electric heating appliances; (4) reduction ofmore » emissions from stoker-fired boiler houses; and (5) reduction of emissions from coal-fired home heating stoves.« less
DESIGN REPORT: LOW-NOX BURNERS FOR PACKAGE BOILERS
The report describes a low-NOx burner design, presented for residual-oil-fired industrial boilers and boilers cofiring conventional fuels and nitrated hazardous wastes. The burner offers lower NOx emission levels for these applications than conventional commercial burners. The bu...
BOILER DESIGN CRITERIA FOR DRY SORBENT SO2 CONTROL WITH LOW-NOX BURNERS: NEW UNIT APPLICATIONS
The report describes a study to define boiler modifications required to achieve 70% SO2 removal with sorbent injection on a large tangentially fired utility boiler without supplemental spray drying. The study is a follow on to a recently completed broader evaluation of boiler des...
Retrofitted coal-fired firetube boiler and method employed therewith
Wagoner, Charles L.; Foote, John P.
1995-01-01
A coal-fired firetube boiler and a method for converting a gas-fired firetube boiler to a coal-fired firetube boiler, the converted boiler including a plurality of combustion zones within the firetube and controlled stoichiometry within the combustion zones.
Combustion performance of pyrolysis oil/ethanol blends in a residential-scale oil-fired boiler
USDA-ARS?s Scientific Manuscript database
A 40 kWth oil-fired commercial boiler was fueled with blends of biomass pyrolysis oil (py-oil) and ethanol to determine the feasibility of using these blends as a replacement for fuel oil in home heating applications. An optimal set of test parameters was determined for the combustion of these blend...
Retrofitted coal-fired firetube boiler and method employed therewith
Wagoner, C.L.; Foote, J.P.
1995-07-04
A coal-fired firetube boiler and a method for converting a gas-fired firetube boiler to a coal-fired firetube boiler are disclosed. The converted boiler includes a plurality of combustion zones within the firetube and controlled stoichiometry within the combustion zones. 19 figs.
Microfine coal firing results from a retrofit gas/oil-designed industrial boiler
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patel, R.; Borio, R.W.; Liljedahl, G.
1995-12-31
The development of a High Efficiency Advanced Coal Combustor (HEACC) has been in progress since 1987 and the ABB Power Plant Laboratories. The initial work on this concept produced an advanced coal firing system that was capable of firing both water-based and dry pulverized coal in an industrial boiler environment. Economics may one day dictate that it makes sense to replace oil or natural gas with coal in boilers that were originally designed to burn these fuels. The objective of the current program is to demonstrate the technical and economic feasibility of retrofitting a gas/oil designed boiler to burn micronizedmore » coal. In support of this overall objective, the following specific areas were targeted: A coal handling/preparation system that can meet the technical requirements for retrofitting microfine coal on a boiler designed for burning oil or natural gas; Maintaining boiler thermal performance in accordance with specifications when burning oil or natural gas; Maintaining NOx emissions at or below 0.6 lb/MBtu; Achieving combustion efficiencies of 98% or higher; and Calculating economic payback periods as a function of key variables. The overall program has consisted of five major tasks: (1) A review of current state-of-the-art coal firing system components; (2) Design and experimental testing of a prototype HEACC burner; (3) Installation and testing of a HEACC system in a commercial retrofit application; (4) Economic evaluation of the HEACC concept for retrofit applications; and (5) Long term demonstration under commercial user demand conditions. This paper will summarize the latest key experimental results (Task 3) and the economic evaluation (Task 4) of the HEACC concept for retrofit applications. 28 figs., 6 tabs.« less
Demonstration of coal reburning for cyclone boiler NO{sub x} control. Appendix, Book 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Based on the industry need for a pilot-scale cyclone boiler simulator, Babcock Wilcox (B&W) designed, fabricated, and installed such a facility at its Alliance Research Center (ARC) in 1985. The project involved conversion of an existing pulverized coal-fired facility to be cyclone-firing capable. Additionally, convective section tube banks were installed in the upper furnace in order to simulate a typical boiler convection pass. The small boiler simulator (SBS) is designed to simulate most fireside aspects of full-size utility boilers such as combustion and flue gas emissions characteristics, fireside deposition, etc. Prior to the design of the pilot-scale cyclone boiler simulator,more » the various cyclone boiler types were reviewed in order to identify the inherent cyclone boiler design characteristics which are applicable to the majority of these boilers. The cyclone boiler characteristics that were reviewed include NO{sub x} emissions, furnace exit gas temperature (FEGT) carbon loss, and total furnace residence time. Previous pilot-scale cyclone-fired furnace experience identified the following concerns: (1) Operability of a small cyclone furnace (e.g., continuous slag tapping capability). (2) The optimum cyclone(s) configuration for the pilot-scale unit. (3) Compatibility of NO{sub x} levels, carbon burnout, cyclone ash carryover to the convection pass, cyclone temperature, furnace residence time, and FEGT.« less
MUNICIPAL WASTE COMBUSTION ASSESSMENT: FOSSIL FUEL CO-FIRING
The report identifies refuse derived fuel (RDF) processing operations and various RDF types; describes such fossil fuel co-firing techniques as coal fired spreader stokers, pulverized coal wall fired boilers, pulverized coal tangentially fired boilers, and cyclone fired boilers; ...
Designing, installing and operating low NOx combustion systems in power plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lazzeri, L.; Santis, R. de
1997-09-01
Ansaldo Energia, in strict cooperation with the Italian Electricity Board (ENEL), has developed and implemented innovative technologies for in furnace NOx control which have been applied, both in italy and abroad, on over 20,000 MWe boilers of every kind (Tangentially Fired, Front Fired, Opposite Fired) and for different fuels like oil, gas, coal and ORIMULSION{reg_sign}. Taking advantage of innovative low NOx burners and of optimized air and fuel staging techniques NOx reductions up to 85% have been obtained with no significant impact on boiler efficiency. The paper describes: characteristics and industrial application of TEA{reg_sign} oil/gas LNB which is now capablemore » of attaining NOx reductions up to 60% in respect to original circular burners; development and industrial applications of the TEA C{reg_sign} (oil/coal) LNB, capable of attaining NOx reductions up to 50% with contemporary control of unburned carbon levels (typical values less than 300 ppm NOx corrected to 6% O{sub 2} and less than 7% UBC); application of reburning oil over oil and gas over oil for both tangential and front-opposite fired boilers rated up 660 MWe; and information on the CEE THERMIE projects of gas over coal reburning in a 600 MWe Scottish Power boiler and oil over coal and coal over coal reburning in the ENEL plant of Vado Ligure unit 4, rated 320 MWe.« less
33 CFR 145.10 - Locations and number of fire extinguishers required.
Code of Federal Regulations, 2011 CFR
2011-07-01
... vicinity of exits, either inside or outside of spaces. machinery spaces Gas-fired boilers B-II (CO2 or dry chemical) 2 required. Gas-fired boilers B-V 1 required. 1 Oil-fired boilers B-II 2 required. Oil-fired boilers B-V 2 required. 1 Internal combustion or gas turbine engines B-II 1 for each engine. 2 Electric...
33 CFR 145.10 - Locations and number of fire extinguishers required.
Code of Federal Regulations, 2012 CFR
2012-07-01
... vicinity of exits, either inside or outside of spaces. machinery spaces Gas-fired boilers B-II (CO2 or dry chemical) 2 required. Gas-fired boilers B-V 1 required. 1 Oil-fired boilers B-II 2 required. Oil-fired boilers B-V 2 required. 1 Internal combustion or gas turbine engines B-II 1 for each engine. 2 Electric...
33 CFR 145.10 - Locations and number of fire extinguishers required.
Code of Federal Regulations, 2013 CFR
2013-07-01
... vicinity of exits, either inside or outside of spaces. machinery spaces Gas-fired boilers B-II (CO2 or dry chemical) 2 required. Gas-fired boilers B-V 1 required. 1 Oil-fired boilers B-II 2 required. Oil-fired boilers B-V 2 required. 1 Internal combustion or gas turbine engines B-II 1 for each engine. 2 Electric...
33 CFR 145.10 - Locations and number of fire extinguishers required.
Code of Federal Regulations, 2014 CFR
2014-07-01
... vicinity of exits, either inside or outside of spaces. machinery spaces Gas-fired boilers B-II (CO2 or dry chemical) 2 required. Gas-fired boilers B-V 1 required. 1 Oil-fired boilers B-II 2 required. Oil-fired boilers B-V 2 required. 1 Internal combustion or gas turbine engines B-II 1 for each engine. 2 Electric...
33 CFR 145.10 - Locations and number of fire extinguishers required.
Code of Federal Regulations, 2010 CFR
2010-07-01
... vicinity of exits, either inside or outside of spaces. machinery spaces Gas-fired boilers B-II (CO2 or dry chemical) 2 required. Gas-fired boilers B-V 1 required. 1 Oil-fired boilers B-II 2 required. Oil-fired boilers B-V 2 required. 1 Internal combustion or gas turbine engines B-II 1 for each engine. 2 Electric...
REBURNING APPLICATION TO FIRETUBE PACKAGE BOILERS
The report gives results of pilot-scale experimental research that examined the physical and chemical phenomena associated with the NOx control technology of reburning applied to gas- and liquid-fired firetube package boilers. Reburning (staged fuel combustion) diverts some of th...
DOE Office of Scientific and Technical Information (OSTI.GOV)
De Michele, G.; Pasini, S.; Tarli, R.
1996-01-01
ENEL is conducting a comprehensive modification program within its generating system, in order to comply with the new Italian air quality standards for fossil fuel-fired power plants, which set a limit for NO{sub x} of 200 mg/Nm{sup 3} corrected to 3% O{sub 2} for oil and gas and to 6% O{sub 2} for coal. Among all combustion modification technologies reburning has proven particularly attractive, since it has been demonstrated that it generally permits to satisfy the regulatory requirements in gas and oil fired units, thus avoiding the use of SCR. The ENEL generating system essentially employs tangentially fired (TF) andmore » front/opposed wall fired boilers belonging, respectively, to the CEI and Babcock & Wilcox (B&W) technology, designed and constructed by Ansaldo and Franco Tosi (now bought by Ansaldo). In this framework ENEL has signed respectively with Ansaldo Energia and Combustion Engineering Inc. (CEI), and with Ansaldo Energia two separate agreements to apply Reburn Technology in oil and gas, tangentially-fired (TF) utility boilers, the first, and oil and gas wall-fired (WF) utility boilers, the second, both in Italy and abroad. This paper outlines the technical knowledge available for the design of reburn systems for a retrofit application and describes the main results obtained, after retrofit, at Torvaldaliga No. 2 power station, 320 MW{sub e} (TF), firing both oil and gas as reburn fuels, and at Cassano unit No. 1, 75 MW{sub e} (WF), firing gas as main and reburn fuels. Reference is also made to the development of the projects for the application of the technology at Monfalcone, 320 MW{sub e} (WF), in the oil over oil configuration, whose demonstration is planned for the Autumn of 1995, and at Porto Tolle unit No. 1, 660 MW{sub e} (TF), that is planned to start in January 1996.« less
RDF (Refuse Derived Fuel) Utilization in a Navy Stoker Coal-Fired Boiler.
1984-10-01
the energy production in any coal-fired boiler conversion consideration. The selection of the actual RDF to be used in a converted boiler should be... industrial boilers by gathering information from the Navy Energy and Environmental Support Activity, engineering field divi- sions, and field...activities. Currently the Navy has 27 industrial size boilers firing coal as a primary fuel and 10 firing coal as a secondary fuel. The four principal factors
Fire-tube boiler optimization criteria and efficiency indicators rational values defining
NASA Astrophysics Data System (ADS)
Batrakov, P. A.; Mikhailov, A. G.; Ignatov, V. Yu
2018-01-01
Technical and economic calculations problems solving with the aim of identifying the opportunity to recommend the project for industrial implementation are represented in the paper. One of the main determining factors impacting boiler energy efficiency is the exhaust gases temperature, as well as the furnace volume thermal stress. Fire-tube boilers with different types of furnaces are considered in the study. The fullest analysis of the boiler performance thermal and technical indicators for the following engineering problem: Q=idem, M=idem and evaluation according to η, B is presented. The furnace with the finned ellipse profile application results in the fuel consumption decrease due to a more efficient heat exchange surface of the furnace compared to other examined ones.
Feasibility of a medium-size central cogenerated energy facility, energy management memorandum
NASA Astrophysics Data System (ADS)
Porter, R. W.
1982-09-01
The thermal-economic feasibility was studied of a medium-size central cogenerated energy facility designed to serve five varied industries. Generation options included one dual-fuel diesel and one gas turbine, both with waste heat boilers, and five fired boilers. Fuels included natural gas, and for the fired-boiler cases, also low-sulphur coal and municipal refuse. The fired-boiler cogeneration systems employed back-pressure steam turbines. For coal and refuse, the option of steam only without cogeneration was also assessed. The refuse-fired cases utilized modular incinerators. The options provided for a wide range of steam and electrical capacities. Deficient steam was assumed generated independently in existing equipment. Excess electrical power over that which could be displaced was assumed sold to Commonwealth Edison Company under PURPA (Public Utility Regulator Policies Act). The facility was assumed operated by a mutually owned corporation formed by the cogenerated power users. The economic analysis was predicted on currently applicable energy-investment tax credits and accelerated depreciation for a January 1985 startup date. Based on 100% equity financing, the results indicated that the best alternative was the modular-incinerator cogeneration system.
NASA Astrophysics Data System (ADS)
Kumar, M.; Singh, H.; Singh, N.; Chavan, N. M.; Kumar, S.; Joshi, S. V.
2015-12-01
The erosion-corrosion (E-C) behavior of a cold-spray nanostructured Ni-20Cr coating was studied under cyclic conditions in a coal-fired boiler. This study was done for 15 cycles (1500 h), in which each cycle comprised 100 h of heating in the boiler environment, followed by 1 h of cooling under ambient air conditions. The E-C extent was evaluated in terms of thickness loss data of the samples. The eroded-corroded samples were characterized using XRD, SEM/EDS, and x-ray mapping analyses. The nanostructured coating offered excellent E-C protection to boiler tube material (SA 516 steel) under harsh live conditions of the boiler. This E-C resistance offered by investigated coating may be attributed to the presence of protective NiO and Cr2O3 phases in its oxide scale and its superior as-sprayed microhardness.
Heating boilers in Krakow, Poland: Options for improving efficiency and reducing emissions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cyklis, P.; Kowalski, J.; Kroll, J.
1995-08-01
In Krakow, Poland, coal-fired boilers are used to heat single apartment buildings and local heating districts. The population includes 2,930 small, hand-fired boilers and 227 larger traveling grate stoker-fired boilers. These boilers are important contributors to air quality problems in Krakow, and an assessment of their efficiency and emissions characteristics was recently undertaken. For the larger, stoker-fired boilers, efficiency was measured using a stack-loss method. In addition to the normal baseline fuel, the effects of coal cleaning and grading were evaluated. Testing was done at two selected sites. Boiler efficiencies were found to be low--50% to 67%. These boilers operatemore » without combustion controls or instrumentation for flue gas analysis. As a result, excess air levels are very high--up to 400%--leading to poor performance. Emissions were found to be typical for boilers of this type. Using the improved fuels yields reductions in emissions and improvement in efficiency when combined with proper adjustments. In the case of the hand-fired boilers, one set of cast-iron boilers and one set of steel boilers were tested. Efficiency in this case was measured using an input-output method for sets of three boilers taken together as a system. Emissions from these boilers are lowest when low volatile fuels, such as coke or smokeless briquettes, are used.« less
NASA Astrophysics Data System (ADS)
Yue, Tao; Gao, Xiang; Gao, Jiajia; Tong, Yali; Wang, Kun; Zuo, Penglai; Zhang, Xiaoxi; Tong, Li; Wang, Chenlong; Xue, Yifeng
2018-07-01
In the past decade, due to the management policies and coal combustion controls in Beijing, the consumption of natural gas has increased gradually. Nevertheless, the research on the emission characteristics of gaseous pollutants emitted from gas-fired industrial boilers, especially considering the influence of low nitrogen (low-NOx) retrofit policy of gas boilers, is scarcely. In this study, based on literature and field investigations, onsite measurements of NOx, CO, NH3 and VOCs (Volatile Organic Compounds) emissions from gas-fired industrial boilers as well as the key factors that affected the emission of gaseous pollutants were discussed. Category-specific emission factors (EFs) of NOx, CO, NH3 and VOCs were obtained from the field measurements of 1107 "low-NOx" retrofitted and unabated gas-fired industrial boilers. Our results showed that operating load and control measures were the two key factors affecting the formation of gaseous pollutants. The EFs of NOx (EFNOx) and CO (EFCO) of atmospheric combustion boilers (ACBs) were much higher than the EFs of chamber combustion boilers (CCBs). The total emissions of NOx, CO, NH3 and VOCs from gas-fired industrial boilers in Beijing in the year of 2015 were estimated at 10489.6 t, 3272.8 t, 196.4 t and 235.4 t, respectively. Alkanes, BTEX, oxygenated VOCs and non-reactive organic matter were the four main chemical components of VOCs. As for the spatial distributions, the emissions of NOx, CO, NH3 and VOCs from gas-fired industrial boilers in Beijing were predominantly concentrated in central six urban districts. In the future, more detailed investigation and field tests for all kinds of gas-fired industrial boilers are still greatly needed to achieve more reliable estimations of atmospheric pollutants from gas-fired industrial boilers.
40 CFR 76.5 - NOX emission limitations for Group 1 boilers.
Code of Federal Regulations, 2010 CFR
2010-07-01
... wall-fired boiler (other than units applying cell burner technology) shall not discharge, or allow to... input on an annual average basis for tangentially fired boilers. (2) 0.50 lb/mmBtu of heat input on an annual average basis for dry bottom wall-fired boilers (other than units applying cell burner technology...
The report describes an investigation of the adequacy of a modeling approach in predicting the thermal environment and flow field of pulverized-coal-fired utility boilers. Two 420 MWe coal-fired boilers were evaluated: a single-wall-fired unit and a tangentially fired unit, repre...
11. RW Meyer Sugar Mill: 18761889. Locomotive=type, firetube, portable boiler, ...
11. RW Meyer Sugar Mill: 1876-1889. Locomotive=type, fire-tube, portable boiler, model No. 1, Manufactured by Ames Iron Works, Oswego, New York, 1879. 120 lbs./sq. in. working pressure, 66 sq. ft. heating surface in tubes. View: the boiler provided steam for steam engine which in turn powered the centrifugals. View shows front fire box, end of boiler. Below fire-box,used for removing ashes, is a door. Circular openings at the rear of the fire-box are where fire-tubes connected with furnace. Column to right of fire-box carried pressure and water level gauges. Fluted chimney-type structure is steam-port, safety valve, and whistle. Weights originally sat on the arm extending from the top of the port and controlled the boiler pressure. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI
40 CFR 65.149 - Boilers and process heaters.
Code of Federal Regulations, 2010 CFR
2010-07-01
... stream is not introduced as or with the primary fuel, a temperature monitoring device in the fire box...-throughput transfer racks, as applicable, shall meet the requirements of this section. (2) The vent stream... thermal units per hour) or greater. (ii) A boiler or process heater into which the vent stream is...
Coal reburning for cost-effective NO{sub x} compliance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Folsom, B.A.; Sommer, T.M.; Engelhardt, D.A.
1997-12-31
This paper presents the application of micronized coal reburning to a cyclone-fired boiler in order to meet RACT emissions requirements in New York State. Discussed in the paper are reburning technology, the use of a coal micronizer, and the application of the technology to an Eastman Kodak unit. The program is designed to demonstrate the economical reduction of NO{sub x} emissions without adverse impact to the boiler.
Drying Milk With Boiler Exhaust
NASA Technical Reports Server (NTRS)
Broussard, M. R.
1984-01-01
Considerable energy saved in powdered-milk industry. Only special requirement boiler fired with natural gas or other clean fuel. Boiler flue gas fed to spray drier where it directly contacts product to be dried. Additional heat supplied by auxillary combustor when boiler output is low. Approach adaptable to existing plants with minimal investment because most already equipped with natural-gas-fired boilers.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-20
... the Operation of Outdoor Wood-Fired Boilers AGENCY: Environmental Protection Agency (EPA). ACTION... the operation of outdoor wood-fired boilers (OWBs). EPA is approving this revision to reduce particular matter emissions from the operation of outdoor wood-fired boilers in accordance with the...
12. Forward end of Boiler Room showing open firing doors ...
12. Forward end of Boiler Room showing open firing doors for boilers. Note ladderway retracted overhead by which firemen entered and left Boiler Room. Coal ejectors shown at extreme left of view. - Steamboat TICONDEROGA, Shelburne Museum Route 7, Shelburne, Chittenden County, VT
NASA Astrophysics Data System (ADS)
Zong, Y.; He, K.; Zhang, Q.; Hong, C.
2016-12-01
Coal has long been an important energy type of Beijing's energy consumption. Since 1998, to improve urban air quality, Beijing has vigorously promoted the structure optimization of energy consumption. Primary measures included the implementation of strict emission standards for coal-fired power plant boilers, subsidized replacement and after-treatment retrofit of coal-fired boilers, the mandatory application of low-sulfur coal, and the accelerated use of natural gas, imported electricity and other clean energy. This work attempts to assess the emission reduction benefits on measures of three sectors, including replacing with clean energy and application of end-of-pipe control technologies in power plants, comprehensive control on coal-fired boilers and residential heating renovation. This study employs the model of Multi-resolution Emission Inventory for China (MEIC) to quantify emission reductions from upfront measures. These control measures have effectively reduced local emissions of major air pollutants in Beijing. The total emissions of PM2.5, PM10, SO2 and NOX from power plants in Beijing are estimated to have reduced 14.5 kt, 23.7 kt, 45.0 kt and 7.6 kt from 1998 to 2013, representing reductions of 86%, 87%, 85% and 16%, respectively. Totally, 14.3 kt, 24.0 kt, 136 kt and 48.7kt of PM2.5, PM10, SO2 and NOX emissions have been mitigated due to the comprehensive control measures on coal-fired boilers from 1998 to 2013. Residential heating renovation projects by replacing coal with electricity in Beijing's conventional old house areas contribute to emission reductions of 630 t, 870 t, 2070 t and 790 t for PM2.5, PM10, SO2 and NOX, respectively.
Co-firing switchgrass in a 50 MW pulverized coal boiler
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ragland, K.W.; Aerts, D.J.; Weiss, C.
1996-12-31
Switchgrass is being co-fired with pulverized coal in a 50 MW wall-fired, radiant boiler at MG&E`s Blount Street generating station. Shredded switchgrass is fed to a hammermill onto a live bottom storage bunker. Twin screw augers move the switchgrass onto a belt conveyor which leads to a rotary air lock valve and through a pressurized pipe to the boiler where it is injected into the furnace at two points between first and second level coal burners. The main objective of the project is to evaluate the boiler performance, slagging behavior, and emissions of the co-fired switchgrass at replacement of ratesmore » of up to 20% by mass (13% by heat input). Initial co-firing tests to examine fuel handling and feeding, combustion behavior, boiler response and emissions are favorable. In November a 100 hour co-fire test is planned.« less
1968-05-01
flue gas . Is one. The more popular method Is wet limestone scrubbing. In the limestone Injection system, ground limestone Is mixed with the coal and...is removed. The remainder must be eliminated from the flue gas as SO2 by wet scrubbing. Reduced boiler efficiency, due to ash accumulation on the...use of the fluldlzed-bed boiler, rather than a conventional coal-fired boiler requiring a flue gas cleanup system, will result In an
Control Techtronics International
DOE Office of Scientific and Technical Information (OSTI.GOV)
West, J.
1995-12-31
Polish graded coal can be burned in existing stoker boilers and meet the 1998 Air Quality standard. This is accomplished with the Control Techtronics microprocessor-based combustion controller accurately and repeatedly: (a) matching the combustion air to the coal firing rate, with continuous stack sensor feedback; (b) continuously varying the boiler`s firing rate based on output water temperature or steam pressure; (c) continuously varying the exhaust fan`s speed to maintain minimum negative pressure in the boiler`s combustion chamber; and recirculating a portion of the flue gas, at varying amounts throughout the boiler`s firing rate. Systems for five boilers have been installedmore » and are operating on MPEC`s Balicka plant in Krakow. Control Techtronics International has $10 million of U.S. Export-Import Bank funds available for similar projects throughout Poland.« less
Characterization of Oxy-combustion Impacts in Existing Coal-fired Boilers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adams, Bradley; Davis, Kevin; Senior, Constance
Reaction Engineering International (REI) managed a team of experts from University of Utah, Siemens Energy, Praxair, Vattenfall AB, Sandia National Laboratories, Brigham Young University (BYU) and Corrosion Management Ltd. to perform multi-scale experiments, coupled with mechanism development, process modeling and CFD modeling, for both applied and fundamental investigations. The primary objective of this program was to acquire data and develop tools to characterize and predict impacts of CO{sub 2} flue gas recycle and burner feed design on flame characteristics (burnout, NO{sub x}, SO{sub x}, mercury and fine particle emissions, heat transfer) and operational concerns (fouling, slagging and corrosion) inherent inmore » the retrofit of existing coal-fired boilers for oxy-coal combustion. Experimental work was conducted at Sandia National Laboratories’ Entrained Flow Reactor, the University of Utah Industrial Combustion Research Facility, and Brigham Young University. Process modeling and computational fluid dynamics (CFD) modeling was performed at REI. Successful completion of the project objectives resulted in the following key deliverables: 1) Multi-scale test data from 0.1 kW bench-scale, 100 kW and 200 kW laboratory-scale, and 1 MW semi-industrial scale combustors that describe differences in flame characteristics, fouling, slagging and corrosion for coal combustion under air-firing and oxygen-firing conditions, including sensitivity to oxy-burner design and flue gas recycle composition. 2) Validated mechanisms developed from test data that describe fouling, slagging, waterwall corrosion, heat transfer, char burnout and sooting under coal oxy-combustion conditions. The mechanisms were presented in a form suitable for inclusion in CFD models or process models. 3) Principles to guide design of pilot-scale and full-scale coal oxy-firing systems and flue gas recycle configurations, such that boiler operational impacts from oxy-combustion retrofits are minimized. 4) Assessment of oxy-combustion impacts in two full-scale coal-fired utility boiler retrofits based on computational fluid dynamics (CFD) modeling of air-fired and oxygen-fired operation. This research determined that it is technically feasible to retrofit the combustion system in an air-fired boiler for oxy-fired operation. The impacts of CO{sub 2} flue gas recycle and burner design on flame characteristics (burnout, NO{sub x}, SO{sub x}, mercury and fine particle emissions, heat transfer) and operational concerns (fouling, slagging and corrosion) were minimal, with the exception of high sulfur levels resulting from untreated flue gas recycle with medium and high-sulfur coals. This work focused on combustion in the radiant and convective sections of the boiler and did not address boiler system integration issues, plant efficiencies, impacts on downstream air pollution control devices, or CO{sub 2} capture and compression. The experimental data, oxy-firing system principles and oxy-combustion process mechanisms provided by this work can be used by electric utilities, boiler OEMs, equipment suppliers, design firms, software vendors, consultants and government agencies to assess retrofit applications of oxy-combustion technologies to existing boilers and to guide development of new designs.« less
Apparatus and method of controlling the thermal performance of an oxygen-fired boiler
Levasseur, Armand A.; Kang, Shin G.; Kenney, James R.; Edberg, Carl D.
2017-09-05
Disclosed herein is a method of controlling the operation of an oxy-fired boiler; the method comprising combusting a fuel in a boiler; producing a heat absorption pattern in the boiler; discharging flue gases from the boiler; recycling a portion of the flue gases to the boiler; combining a first oxidant stream with the recycled flue gases to form a combined stream; splitting the combined stream into several fractions; and introducing each fraction of the combined stream to the boiler at different points of entry to the boiler.
Research, Development and Demonstration of Bio-Mass Boiler for Food Industry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fisher, Steve; Knapp, David
2012-07-01
Frito-Lay is working to reduce carbon emissions from their manufacturing plants. As part of this effort, they invested in a biomass-fired boiler at the Topeka, Kansas, plant. Frito-Lay partnered with Burns & McDonnell Engineering, Inc. and CPL Systems, Inc., to design and construct a steam producing boiler using carbon neutral fuels such as wood wastes (e.g. tree bark), shipping pallets, and used rubber vehicle tires. The U.S. Department of Energy (DOE) joined with Frito-Lay, Burns & McDonnell, and CPL to analyze the reductions in carbon dioxide (CO 2) emissions that result from use of biomass-fired boilers in the food manufacturingmore » environment. DOE support provided for the data collection and analysis, and reporting necessary to evaluate boiler efficiencies and reductions in CO 2 emissions. The Frito-Lay biomass-fired boiler has resulted in significant reductions in CO 2 emissions from the Topeka production facility. The use of natural gas has been reduced by 400 to 420 million standard cubic feet per year with corresponding reductions of 24,000 to 25,000 tons of CO 2. The boiler does require auxiliary functions, however, that are unnecessary for a gas-fired boiler. These include heavy motors and fans for moving fuel and firing the boiler, trucks and equipment for delivering the fuel and moving at the boiler plant, and chippers for preparing the fuel prior to delivery. Each of these operations requires the combustion of fossil fuels or electricity and has associated CO 2 emissions. Even after accounting for each of these auxiliary processes, however, the biomass-fired boiler results in net emission reductions of 22,500 to 23,500 tons of CO 2 per year.« less
76 FR 1192 - Notice of Lodging of Consent Decree Under the Clean Air Act
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-07
..., the Commonwealth will control particulate matter emissions at the facilities by either shutting down coal-fired boilers, installing air emission controls, or converting the coal-fired boilers to natural gas-fired boilers. The Commonwealth will pay a civil penalty of $300,000 for past violations. The...
46 CFR 52.01-35 - Auxiliary, donkey, fired thermal fluid heater, and heating boilers.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 2 2011-10-01 2011-10-01 false Auxiliary, donkey, fired thermal fluid heater, and heating boilers. 52.01-35 Section 52.01-35 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-35 Auxiliary, donkey, fired thermal...
46 CFR 52.01-35 - Auxiliary, donkey, fired thermal fluid heater, and heating boilers.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false Auxiliary, donkey, fired thermal fluid heater, and heating boilers. 52.01-35 Section 52.01-35 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-35 Auxiliary, donkey, fired thermal...
46 CFR 52.01-35 - Auxiliary, donkey, fired thermal fluid heater, and heating boilers.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Auxiliary, donkey, fired thermal fluid heater, and heating boilers. 52.01-35 Section 52.01-35 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-35 Auxiliary, donkey, fired thermal...
46 CFR 52.01-35 - Auxiliary, donkey, fired thermal fluid heater, and heating boilers.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 2 2013-10-01 2013-10-01 false Auxiliary, donkey, fired thermal fluid heater, and heating boilers. 52.01-35 Section 52.01-35 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-35 Auxiliary, donkey, fired thermal...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-15
... the Operation of Outdoor Wood-Fired Boilers AGENCY: Environmental Protection Agency (EPA). ACTION... from the operation of outdoor wood-fired boilers. This action is being taken under the Clean Air Act... the operation of outdoor wood-fired boilers (OWBs). I. Background On July 18, 1997 (62 FR 38652), EPA...
Joint Long-Range Energy Study for Greater Fairbanks Military Complex
2005-02-01
be viewed as a two - stage processor of a fuel or feedstock. The feedstock is first gasified using high-temperature plasma heating sys- tems at...Coal-Fired Boilers with New Circulating Fluidized- Bed Boilers (CFBs). EAFB anticipates replacing two current boilers with two new boilers. This...definition to support DD Form 1391 budget level cost estimates for new coal-fired CHPPs at FWA and EAFB and for two new coal-fired CFBs at EAFB • update
40 CFR 63.11194 - What is the affected source of this subpart?
Code of Federal Regulations, 2014 CFR
2014-07-01
... requirements of this subpart after June 4, 2010 due to a fuel switch from gaseous fuel to solid fossil fuel, biomass, or liquid fuel is considered to be an existing source under this subpart as long as the boiler... applicability criteria at the time you commence reconstruction. (e) An existing dual-fuel fired boiler meeting...
40 CFR 63.11194 - What is the affected source of this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
... requirements of this subpart after June 4, 2010 due to a fuel switch from gaseous fuel to solid fossil fuel, biomass, or liquid fuel is considered to be an existing source under this subpart as long as the boiler... applicability criteria at the time you commence reconstruction. (e) An existing dual-fuel fired boiler meeting...
EPA Research Highlights: Minimizing SO3 Emissions from Coal-Fired Power Plants
There have been substantial reductions in emissions of particulate matter, nitrogen oxides, and sulfur dioxide through the application of control technologies and strategies. The installation of control technologies has added to the complexity of coal-fired boilers and their ope...
77 FR 49830 - Notice of Lodging of Proposed Amendment to the Consent Decree Under the Clean Air Act
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-17
... control particulate matter emissions at its Huntingdon, Pennsylvania facility (``the Huntingdon facility'') by either shutting down coal-fired boilers, installing air emission controls on the existing unit, or converting the coal-fired boilers to natural gas-fired boilers by June 30, 2012. The Commonwealth did not...
46 CFR 52.01-35 - Auxiliary, donkey, fired thermal fluid heater, and heating boilers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... heating boilers. 52.01-35 Section 52.01-35 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS General Requirements § 52.01-35 Auxiliary, donkey, fired thermal fluid heater, and heating boilers. (a) To determine the appropriate part of the regulations where...
Solar augmentation for process heat with central receiver technology
NASA Astrophysics Data System (ADS)
Kotzé, Johannes P.; du Toit, Philip; Bode, Sebastian J.; Larmuth, James N.; Landman, Willem A.; Gauché, Paul
2016-05-01
Coal fired boilers are currently one of the most widespread ways to deliver process heat to industry. John Thompson Boilers (JTB) offer industrial steam supply solutions for industry and utility scale applications in Southern Africa. Transport cost add significant cost to the coal price in locations far from the coal fields in Mpumalanga, Gauteng and Limpopo. The Helio100 project developed a low cost, self-learning, wireless heliostat technology that requires no ground preparation. This is attractive as an augmentation alternative, as it can easily be installed on any open land that a client may have available. This paper explores the techno economic feasibility of solar augmentation for JTB coal fired steam boilers by comparing the fuel savings of a generic 2MW heliostat field at various locations throughout South Africa.
40 CFR 96.304 - Applicability.
Code of Federal Regulations, 2013 CFR
2013-07-01
... requirements of this subpart and subparts BBBB through HHHH of this part: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine serving at any time, since the later of... combust fossil fuel or to serve a generator with nameplate capacity of more than 25 MWe producing...
Study of flue-gas temperature difference in supercritical once-through boiler
NASA Astrophysics Data System (ADS)
Kang, Yanchang; Li, Bing; Song, Ang
2018-02-01
The 600 MW coal-fired once-through Boilers with opposed firing at a power plant are found to experience marked temperature variation and even overtemperature on the wall of the heating surface as a result of flue-gas temperature (FGT) variation in the boiler. In this study, operational adjustments were made to the pulverizing, combustion, and secondary air box systems in these boilers, in order to solve problems in internal combustion. The adjustments were found to reduce FGT difference and optimize the boiler’ combustion conditions. The results of this study can provide a reference for optimization of coal-fired boiler of the same type in similar conditions.
40 CFR 97.504 - Applicability.
Code of Federal Regulations, 2013 CFR
2013-07-01
... subpart: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine... paragraph (a)(1) of this section, is not a TR NOX Ozone Season unit begins to combust fossil fuel or to... date on which it both combusts fossil fuel and serves such generator. (b) Any unit in a State (and...
40 CFR 97.504 - Applicability.
Code of Federal Regulations, 2014 CFR
2014-07-01
... subpart: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine... paragraph (a)(1) of this section, is not a TR NOX Ozone Season unit begins to combust fossil fuel or to... date on which it both combusts fossil fuel and serves such generator. (b) Any unit in a State (and...
40 CFR 97.204 - Applicability.
Code of Federal Regulations, 2011 CFR
2011-07-01
...: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine serving... unit begins to combust fossil fuel or to serve a generator with nameplate capacity of more than 25 MWe... this section on the first date on which it both combusts fossil fuel and serves such generator. (b) The...
40 CFR 97.204 - Applicability.
Code of Federal Regulations, 2010 CFR
2010-07-01
...: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine serving... unit begins to combust fossil fuel or to serve a generator with nameplate capacity of more than 25 MWe... this section on the first date on which it both combusts fossil fuel and serves such generator. (b) The...
40 CFR 97.104 - Applicability.
Code of Federal Regulations, 2014 CFR
2014-07-01
...: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine serving... unit begins to combust fossil fuel or to serve a generator with nameplate capacity of more than 25 MWe... this section on the first date on which it both combusts fossil fuel and serves such generator. (b) The...
Code of Federal Regulations, 2012 CFR
2012-07-01
...: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine serving... unit begins to combust fossil fuel or to serve a generator with nameplate capacity of more than 25 MWe... this section on the first date on which it both combusts fossil fuel and serves such generator. (b) The...
40 CFR 97.404 - Applicability.
Code of Federal Regulations, 2014 CFR
2014-07-01
... subpart: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine... paragraph (a)(1) of this section, is not a TR NOX Annual unit begins to combust fossil fuel or to serve a... both combusts fossil fuel and serves such generator. (b) Any unit in a State (and Indian country within...
40 CFR 97.204 - Applicability.
Code of Federal Regulations, 2014 CFR
2014-07-01
...: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine serving... unit begins to combust fossil fuel or to serve a generator with nameplate capacity of more than 25 MWe... this section on the first date on which it both combusts fossil fuel and serves such generator. (b) The...
Code of Federal Regulations, 2010 CFR
2010-07-01
...: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine serving... unit begins to combust fossil fuel or to serve a generator with nameplate capacity of more than 25 MWe... this section on the first date on which it both combusts fossil fuel and serves such generator. (b) The...
40 CFR 97.204 - Applicability.
Code of Federal Regulations, 2013 CFR
2013-07-01
...: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine serving... unit begins to combust fossil fuel or to serve a generator with nameplate capacity of more than 25 MWe... this section on the first date on which it both combusts fossil fuel and serves such generator. (b) The...
40 CFR 97.204 - Applicability.
Code of Federal Regulations, 2012 CFR
2012-07-01
...: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine serving... unit begins to combust fossil fuel or to serve a generator with nameplate capacity of more than 25 MWe... this section on the first date on which it both combusts fossil fuel and serves such generator. (b) The...
40 CFR 97.404 - Applicability.
Code of Federal Regulations, 2012 CFR
2012-07-01
... subpart: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine... paragraph (a)(1) of this section, is not a TR NOX Annual unit begins to combust fossil fuel or to serve a... both combusts fossil fuel and serves such generator. (b) Any unit in a State (and Indian country within...
40 CFR 97.104 - Applicability.
Code of Federal Regulations, 2013 CFR
2013-07-01
...: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine serving... unit begins to combust fossil fuel or to serve a generator with nameplate capacity of more than 25 MWe... this section on the first date on which it both combusts fossil fuel and serves such generator. (b) The...
40 CFR 97.404 - Applicability.
Code of Federal Regulations, 2013 CFR
2013-07-01
... subpart: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine... paragraph (a)(1) of this section, is not a TR NOX Annual unit begins to combust fossil fuel or to serve a... both combusts fossil fuel and serves such generator. (b) Any unit in a State (and Indian country within...
40 CFR 97.504 - Applicability.
Code of Federal Regulations, 2012 CFR
2012-07-01
... subpart: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine... paragraph (a)(1) of this section, is not a TR NOX Ozone Season unit begins to combust fossil fuel or to... date on which it both combusts fossil fuel and serves such generator. (b) Any unit in a State (and...
Code of Federal Regulations, 2011 CFR
2011-07-01
...: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine serving... unit begins to combust fossil fuel or to serve a generator with nameplate capacity of more than 25 MWe... this section on the first date on which it both combusts fossil fuel and serves such generator. (b) The...
FUNDAMENTAL SCIENCE AND ENGINEERING OF MERCURY CONTROL IN COAL-FIRED POWER PLANTS
The paper discusses the existing knowledge base applicable to mercury (Hg) control in coal-fired boilers and outlines the gaps in knowledge that can be filled by experimentation and data gathering. Mercury can be controlled by existing air pollution control devices or by retrofit...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1991-12-31
It is the objective of the Coal Reburning for Cyclone Boiler NO{sub x} Control Project to fully establish that the cola reburning clean coal technology offers cost-effective alternatives to cyclone operating electric utilities for overall oxides of nitrogen control. The project will evaluate the applicability of the reburning technology for reducing NO{sub x} emissions in full scale cyclone-fired boilers which use coal as a primary fuel. The performance goals while burning coal are: (1) Greater than 50 percent reduction in NO{sub x} emissions, as referenced to the uncontrolled (baseline) conditions at full load. (2) No serious impact on cyclone combustormore » operation, boiler efficiency or boiler fireside performance (corrosion and deposition), or boiler ash removal system performance.« less
Coal reburning for cyclone boiler NO sub x control demonstration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1991-01-01
It is the objective of the Coal Reburning for Cyclone Boiler NO{sub x} Control Project to fully establish that the cola reburning clean coal technology offers cost-effective alternatives to cyclone operating electric utilities for overall oxides of nitrogen control. The project will evaluate the applicability of the reburning technology for reducing NO{sub x} emissions in full scale cyclone-fired boilers which use coal as a primary fuel. The performance goals while burning coal are: (1) Greater than 50 percent reduction in NO{sub x} emissions, as referenced to the uncontrolled (baseline) conditions at full load. (2) No serious impact on cyclone combustormore » operation, boiler efficiency or boiler fireside performance (corrosion and deposition), or boiler ash removal system performance.« less
Industrial Application Study on New-Type Mixed-Flow Fluidized Bed Bottom Ash Cooler
NASA Astrophysics Data System (ADS)
Zeng, B.; Lu, X. F.; Liu, H. Z.
As a key auxiliary device of CFB boiler, the bottom ash cooler (BAC) has a direct influence on secure and economic operation of the boiler. The operating situation of domestic CFB power plant is complex and changeable with a bad coal-fired condition. The principle for designing BAC suitable for the bad coal-fired condition and high parameter CFB boilers was summarized in this paper. Meanwhile, a new-type mixed-flow fluidized bed bottom ash cooler was successfully designed on the basis of the comprehensive investigation on the existing BAC s merits and drawbacks. Using coarse/fine slag separation technology and micro-bubbling fluidization are the significant characteristics of this new BAC. This paper also puts great emphasis on its industrial test in a 460t/h CFB boiler. The results indicate that it achieves significant separation of the coarse/fine slag, an obvious cooling effect, no slag block and coking phenomenon, and continuous stable operation. Figs 7, Tabs 4 and Refs 11.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., petroleum, coal, or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired... right-of-way tree trimmings. Boiler means an enclosed fossil-or other-fuel-fired combustion device used... means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine: (1...
Code of Federal Regulations, 2011 CFR
2011-07-01
..., petroleum, coal, or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired... right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used..., fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine: (1) Having equipment used...
Code of Federal Regulations, 2014 CFR
2014-07-01
..., petroleum, coal, or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired... right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used..., fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine: (1) Having equipment used...
Code of Federal Regulations, 2012 CFR
2012-07-01
..., petroleum, coal, or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired... right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used..., fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine: (1) Having equipment used...
Code of Federal Regulations, 2012 CFR
2012-07-01
..., petroleum, coal, or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired... right-of-way tree trimmings. Boiler means an enclosed fossil-or other-fuel-fired combustion device used... means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine: (1...
Code of Federal Regulations, 2014 CFR
2014-07-01
..., petroleum, coal, or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired... right-of-way tree trimmings. Boiler means an enclosed fossil-or other-fuel-fired combustion device used... means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine: (1...
Code of Federal Regulations, 2010 CFR
2010-07-01
..., petroleum, coal, or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired... right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used..., fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine: (1) Having equipment used...
Code of Federal Regulations, 2013 CFR
2013-07-01
..., petroleum, coal, or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired... right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used..., fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine: (1) Having equipment used...
Code of Federal Regulations, 2013 CFR
2013-07-01
..., petroleum, coal, or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired... right-of-way tree trimmings. Boiler means an enclosed fossil-or other-fuel-fired combustion device used... means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine: (1...
Code of Federal Regulations, 2010 CFR
2010-07-01
..., petroleum, coal, or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired... right-of-way tree trimmings. Boiler means an enclosed fossil-or other-fuel-fired combustion device used... means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine: (1...
Mutagenicity in emissions from coal- and oil-fired boilers.
Alfheim, I; Bergström, J G; Jenssen, D; Møller, M
1983-01-01
The mutagenicity of emission samples from three oil-fired and four coal-fired boilers have been compared by using the Salmonella/microsome assay. Very little or no mutagenic activity was observed in samples from five of these boilers. The sample from one oil-fired boiler showed mutagenic activity of about 500 revertants/MJ, and the sample from a coal-fired fluidized bed combustor had an activity of 58,000 revertants/MJ measured with strain TA 98 in the absence of metabolic activation. All samples contained substances that were cytotoxic to the test bacteria, thus making it difficult to obtain linear dose-response curves. Mutagenic activity at low levels may remain undetected due to this toxicity of the samples. Samples with mutagenic activity below the detection limit in the Salmonella test have also been tested for forward mutations at the HGPRT locus in V79 hamster cells. Weak mutagenic effects were detected in two of the samples, whereas the sample from one oil-fired boiler remained negative. In this test, as well as in the Salmonella test, a strong cytotoxic effect could be observed with all samples. PMID:6825617
NASA Astrophysics Data System (ADS)
Talovskaya, Anna V.; Osipova, Nina A.; Yazikov, Egor G.; Shakhova, Tatyana S.
2017-11-01
The article deals with assessment of anthropogenic pollution in vicinity of local boilers using the data on microelement composition of solid airborne particles deposited in snow. The anthropogenic feature of elevated accumulation levels of solid airborne particles deposited in snow in the vicinity of coal-fired boiler house is revealed in elevated concentrations (3-25 higher than background) of Cd, Sb, Mo, Pb, Sr, Ba, Ni, Mo, Zn and Co. In the vicinity oil-fired boiler house the specific elements as parts of solid airborne particles deposited in snow are V, Ni and Sb, as their content exceeds the background from 3 to 8 times. It is determined that the maximum shares in non-carcinogenic human health risk from chronic inhalation of trace elements to the human body in the vicinity of coal-fired boiler house belong to Al, Mn, Cu, Ba, Co, Pb, whereas in the vicinity of oil-fired boiler house - Al, Mn, Cu, Ni, V.
40 CFR 96.104 - Applicability.
Code of Federal Regulations, 2014 CFR
2014-07-01
... through HH of this part: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired... section, is not a CAIR NOX unit begins to combust fossil fuel or to serve a generator with nameplate... provided in paragraph (a)(1) of this section on the first date on which it both combusts fossil fuel and...
40 CFR 97.604 - Applicability.
Code of Federal Regulations, 2013 CFR
2013-07-01
... subpart: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine... paragraph (a)(1) of this section, is not a TR SO2 Group 1 unit begins to combust fossil fuel or to serve a... both combusts fossil fuel and serves such generator. (b) Any unit in a State (and Indian country within...
40 CFR 96.104 - Applicability.
Code of Federal Regulations, 2013 CFR
2013-07-01
... through HH of this part: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired... section, is not a CAIR NOX unit begins to combust fossil fuel or to serve a generator with nameplate... provided in paragraph (a)(1) of this section on the first date on which it both combusts fossil fuel and...
40 CFR 96.204 - Applicability.
Code of Federal Regulations, 2013 CFR
2013-07-01
... through HHH of this part: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired... section, is not a CAIR SO2 unit begins to combust fossil fuel or to serve a generator with nameplate... provided in paragraph (a)(1) of this section on the first date on which it both combusts fossil fuel and...
40 CFR 96.304 - Applicability.
Code of Federal Regulations, 2014 CFR
2014-07-01
... this subpart and subparts BBBB through HHHH of this part: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine serving at any time, since the later of November 15, 1990 or... paragraph (a)(1) of this section, is not a CAIR NOX Ozone Season unit begins to combust fossil fuel or to...
40 CFR 97.604 - Applicability.
Code of Federal Regulations, 2014 CFR
2014-07-01
... subpart: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine... paragraph (a)(1) of this section, is not a TR SO2 Group 1 unit begins to combust fossil fuel or to serve a... both combusts fossil fuel and serves such generator. (b) Any unit in a State (and Indian country within...
40 CFR 96.104 - Applicability.
Code of Federal Regulations, 2010 CFR
2010-07-01
... through HH of this part: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired... section, is not a CAIR NOX unit begins to combust fossil fuel or to serve a generator with nameplate... provided in paragraph (a)(1) of this section on the first date on which it both combusts fossil fuel and...
40 CFR 96.304 - Applicability.
Code of Federal Regulations, 2011 CFR
2011-07-01
... this subpart and subparts BBBB through HHHH of this part: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine serving at any time, since the later of November 15, 1990 or... paragraph (a)(1) of this section, is not a CAIR NOX Ozone Season unit begins to combust fossil fuel or to...
40 CFR 96.204 - Applicability.
Code of Federal Regulations, 2014 CFR
2014-07-01
... through HHH of this part: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired... section, is not a CAIR SO2 unit begins to combust fossil fuel or to serve a generator with nameplate... provided in paragraph (a)(1) of this section on the first date on which it both combusts fossil fuel and...
40 CFR 97.604 - Applicability.
Code of Federal Regulations, 2012 CFR
2012-07-01
... subpart: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine... paragraph (a)(1) of this section, is not a TR SO2 Group 1 unit begins to combust fossil fuel or to serve a... both combusts fossil fuel and serves such generator. (b) Any unit in a State (and Indian country within...
40 CFR 96.204 - Applicability.
Code of Federal Regulations, 2011 CFR
2011-07-01
... through HHH of this part: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired... section, is not a CAIR SO2 unit begins to combust fossil fuel or to serve a generator with nameplate... provided in paragraph (a)(1) of this section on the first date on which it both combusts fossil fuel and...
40 CFR 97.304 - Applicability.
Code of Federal Regulations, 2013 CFR
2013-07-01
... subpart and subparts BBBB through HHHH of this part: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine serving at any time, since the later of November 15, 1990 or... paragraph (a)(1) of this section, is not a CAIR NOX Ozone Season unit begins to combust fossil fuel or to...
40 CFR 97.304 - Applicability.
Code of Federal Regulations, 2012 CFR
2012-07-01
... subpart and subparts BBBB through HHHH of this part: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine serving at any time, since the later of November 15, 1990 or... paragraph (a)(1) of this section, is not a CAIR NOX Ozone Season unit begins to combust fossil fuel or to...
40 CFR 97.304 - Applicability.
Code of Federal Regulations, 2014 CFR
2014-07-01
... subpart and subparts BBBB through HHHH of this part: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine serving at any time, since the later of November 15, 1990 or... paragraph (a)(1) of this section, is not a CAIR NOX Ozone Season unit begins to combust fossil fuel or to...
40 CFR 96.104 - Applicability.
Code of Federal Regulations, 2011 CFR
2011-07-01
... through HH of this part: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired... section, is not a CAIR NOX unit begins to combust fossil fuel or to serve a generator with nameplate... provided in paragraph (a)(1) of this section on the first date on which it both combusts fossil fuel and...
40 CFR 96.304 - Applicability.
Code of Federal Regulations, 2012 CFR
2012-07-01
... this subpart and subparts BBBB through HHHH of this part: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine serving at any time, since the later of November 15, 1990 or... paragraph (a)(1) of this section, is not a CAIR NOX Ozone Season unit begins to combust fossil fuel or to...
40 CFR 97.704 - Applicability.
Code of Federal Regulations, 2012 CFR
2012-07-01
... subpart: Any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine... paragraph (a)(1) of this section, is not a TR SO2 Group 2 unit begins to combust fossil fuel or to serve a... both combusts fossil fuel and serves such generator. (b) Any unit in a State (and Indian country within...
40 CFR 96.204 - Applicability.
Code of Federal Regulations, 2012 CFR
2012-07-01
... through HHH of this part: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired... section, is not a CAIR SO2 unit begins to combust fossil fuel or to serve a generator with nameplate... provided in paragraph (a)(1) of this section on the first date on which it both combusts fossil fuel and...
40 CFR 96.104 - Applicability.
Code of Federal Regulations, 2012 CFR
2012-07-01
... through HH of this part: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired... section, is not a CAIR NOX unit begins to combust fossil fuel or to serve a generator with nameplate... provided in paragraph (a)(1) of this section on the first date on which it both combusts fossil fuel and...
40 CFR 97.304 - Applicability.
Code of Federal Regulations, 2011 CFR
2011-07-01
... subpart and subparts BBBB through HHHH of this part: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine serving at any time, since the later of November 15, 1990 or... paragraph (a)(1) of this section, is not a CAIR NOX Ozone Season unit begins to combust fossil fuel or to...
40 CFR 97.704 - Applicability.
Code of Federal Regulations, 2014 CFR
2014-07-01
... subpart: Any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine... paragraph (a)(1) of this section, is not a TR SO2 Group 2 unit begins to combust fossil fuel or to serve a... both combusts fossil fuel and serves such generator. (b) Any unit in a State (and Indian country within...
40 CFR 96.304 - Applicability.
Code of Federal Regulations, 2010 CFR
2010-07-01
... this subpart and subparts BBBB through HHHH of this part: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine serving at any time, since the later of November 15, 1990 or... paragraph (a)(1) of this section, is not a CAIR NOX Ozone Season unit begins to combust fossil fuel or to...
40 CFR 97.304 - Applicability.
Code of Federal Regulations, 2010 CFR
2010-07-01
... subpart and subparts BBBB through HHHH of this part: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine serving at any time, since the later of November 15, 1990 or... paragraph (a)(1) of this section, is not a CAIR NOX Ozone Season unit begins to combust fossil fuel or to...
40 CFR 96.204 - Applicability.
Code of Federal Regulations, 2010 CFR
2010-07-01
... through HHH of this part: any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired... section, is not a CAIR SO2 unit begins to combust fossil fuel or to serve a generator with nameplate... provided in paragraph (a)(1) of this section on the first date on which it both combusts fossil fuel and...
40 CFR 97.704 - Applicability.
Code of Federal Regulations, 2013 CFR
2013-07-01
... subpart: Any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine... paragraph (a)(1) of this section, is not a TR SO2 Group 2 unit begins to combust fossil fuel or to serve a... both combusts fossil fuel and serves such generator. (b) Any unit in a State (and Indian country within...
Coal-Fired Boilers at Navy Bases, Navy Energy Guidance Study, Phase II and III.
1979-05-01
several sizes were performed. Central plants containing four equal-sized boilers and central flue gas desulfurization facilities were shown to be less...Conceptual design and parametric cost studies of steam and power generation systems using coal-fired stoker boilers and stack gas scrubbers in
46 CFR 52.25-15 - Fired thermal fluid heaters.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false Fired thermal fluid heaters. 52.25-15 Section 52.25-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-15 Fired thermal fluid heaters. (a) Fired thermal fluid heaters shall be designed...
46 CFR 52.25-15 - Fired thermal fluid heaters.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 2 2013-10-01 2013-10-01 false Fired thermal fluid heaters. 52.25-15 Section 52.25-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-15 Fired thermal fluid heaters. (a) Fired thermal fluid heaters shall be designed...
46 CFR 52.25-15 - Fired thermal fluid heaters.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Fired thermal fluid heaters. 52.25-15 Section 52.25-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-15 Fired thermal fluid heaters. (a) Fired thermal fluid heaters shall be designed...
Analysis of Flue Gas Desulfurization (FGD) Processes for Potential Use on Army Coal-Fired Boilers
1980-09-01
TECHNICAL REPORT N-93 September 1980 ANALYSIS OF FLUE GAS DESULFURIZATION (FGD) PROCESSES FOR POTENTIAL USE ON ARMY COAL-FIRED BOILERS TECHNICAL LIBRARY...REFERENCE: Technical Report N-93, Analysis of Flue Gas Desulfurization (FGD) Ppooesses for Potential Use on Army Coal-Fired Boilers Please take a few...REPORT DOCUMENTATION PAGE 1. REPORT NUMBER CERL-TR-N-93 2. GOVT ACCESSION NO «. TITLE (end Subtitle) ANALYSIS OF FLUE GAS DESULFURIZATION (FGD
[Predicting low NOx combustion property of a coal-fired boiler].
Zhou, Hao; Mao, Jianbo; Chi, Zuohe; Jiang, Xiao; Wang, Zhenhua; Cen, Kefa
2002-03-01
More attention was paid to the low NOx combustion property of the high capacity tangential firing boiler, but the NOx emission and unburned carbon content in fly ash of coal burned boiler were complicated, they were affected by many factors, such as coal character, boiler's load, air distribution, boiler style, burner style, furnace temperature, excess air ratio, pulverized coal fineness and the uniformity of the air and coal distribution, etc. In this paper, the NOx emission property and unburned carbon content in fly ash of a 600 MW utility tangentially firing coal burned boiler was experimentally investigated, and taking advantage of the nonlinear dynamics characteristics and self-learning characteristics of artificial neural network, an artificial neural network model on low NOx combustion property of the high capacity boiler was developed and verified. The results illustrated that such a model can predicate the NOx emission concentration and unburned carbon content under various operating conditions, if combined with the optimization algorithm, the operator can find the best operation condition of the low NOx combustion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Castaldini, C.; Waterland, L.R.
1987-03-01
The two-volume report gives results from field tests of a wood-waste-fired industrial watertube boiler. Two series of tests were performed: one firing dry (11% moisture) wood waste, and the other firing green (34% moisture) wood waste. Emission measurements included: continuous monitoring of flue-gas emissions; source-assessment sampling system (SASS) sampling of the flue gas with subsequent laboratory analysis of samples to give total flue-gas organics in two boiling-point ranges, compound category information within these ranges, specific quantitation of the semi-volatile organic priority pollutants, and flue-gas concentrations of 73 trace elements; Method 5 sampling for particulate; controlled condensation system sampling for SO/submore » 2/ and SO/sub 3/; and grab sampling of boiler mechanical collector hopper ash for inorganic composition determinations. Total organic emissions decreased from 60-135 mg/dscm firing dry wood to 2-65 mg/dscm firing green wood, in parallel with corresponding boiler CO emissions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Castaldini, C.; Waterland, L.R.
1987-03-01
The two-volume report gives results from field tests of a wood-waste-fired industrial watertube boiler. Two series of tests were performed: one firing dry (11% moisture) wood waste, and the other firing green (34% moisture) wood waste. Emission measurements included: continuous monitoring of flue-gas emissions; source-assessment sampling system (SASS) sampling of the flue-gas with subsequent laboratory analysis of samples to give total flue-gas organics in two boiling-point ranges, compound category information within these ranges, specific quantitation of the semi-volatile organic priority pollutants, and flue gas concentrations of 73 trace elements; Method 5 sampling for particulate; controlled condensation system sampling for SO/submore » 2/ and SO/sub 3/; and grab sampling of boiler mechanical collector hopper ash for inorganic and organic composition determinations. Total organic emissions decreased from 60-135 mg/dscm firing dry wood to 2-65 mg/dscm firing green wood, in parallel with corresponding boiler CO emissions.« less
Code of Federal Regulations, 2014 CFR
2014-07-01
... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... electricity through the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming...
Code of Federal Regulations, 2012 CFR
2012-07-01
... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... electricity through the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming...
Code of Federal Regulations, 2014 CFR
2014-07-01
... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... electricity through the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming...
Code of Federal Regulations, 2012 CFR
2012-07-01
... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... electricity through the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming...
Code of Federal Regulations, 2013 CFR
2013-07-01
... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... electricity through the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming...
Code of Federal Regulations, 2013 CFR
2013-07-01
... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... electricity through the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming...
NASA Astrophysics Data System (ADS)
Itahashi, S.; Yan, X.; Song, G.; Yan, J.; Xue, Y.
2017-12-01
Gas-fired boilers will become the main stationary sources of NOx in Beijing. However, the knowledge of gas-fired boilers in Beijing is limited. In the present study, the emission characteristics of NOx, SO2, and CO from gas-fired boilers in Beijing were established using category-specific emission factors (EFs) from field measurements. In order to obtain category-specific EFs, boilers were classified through influence analysis. Factors such as combustion mode, boiler type, and installed capacity were considered critical for establishing EFs because they play significant roles in pollutant formation. The EFs for NOx, CO, and SO2 ranged from 1.42-6.86 g m-3, 0.05-0.67 g m-3 and 0.03-0.48 g m-3. The emissions of NOx, SO2, and CO for gas-fired boilers in Beijing were 11121 t, 468 t, and 222 t in 2014, respectively. The emissions were spatially allocated into grid cells with a resolution of 1 km × 1 km, and the results indicated that top emitters were in central Beijing. The uncertainties were quantified using a Monte Carlo simulation. The results indicated high uncertainties in CO (-157% to 154%) and SO2 (-127% to 182%) emissions, and relatively low uncertainties (-34% to 34%) in NOx emission. Furthermore, approximately 61.2% and 96.8% of the monitored chamber combustion boilers (CCBs) met the standard limits for NOx and SO2, respectively. Concerning NOx, low-NOx burners and NOx emission control measures are urgently needed for implementing of stricter standards. Adopting terminal control measures is unnecessary for SO2, although its concentration occasionally exceeds standard limits, because reduction of its concentration can be achieved thorough control of the sulfur content of natural gas at a stable low level. Furthermore, the atmospheric combustion boilers (ACBs) should be substituted with CCBs, because ACBs have a higher emission despite lower gross installed capacity. The results of this study will enable in understanding and controlling emissions from gas-fired boilers in Beijing.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Petitions Petitioning state Named source categories Connecticut Fossil fuel-fired boilers or other indirect.... New Hampshire Fossil fuel-fired indirect heat exchange combustion units and fossil fuel-fired electric generating facilities which emit ten tons of NOX or more per day. New York Fossil fuel-fired boilers or...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Petitions Petitioning state Named source categories Connecticut Fossil fuel-fired boilers or other indirect.... New Hampshire Fossil fuel-fired indirect heat exchange combustion units and fossil fuel-fired electric generating facilities which emit ten tons of NOX or more per day. New York Fossil fuel-fired boilers or...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Petitions Petitioning state Named source categories Connecticut Fossil fuel-fired boilers or other indirect.... New Hampshire Fossil fuel-fired indirect heat exchange combustion units and fossil fuel-fired electric generating facilities which emit ten tons of NOX or more per day. New York Fossil fuel-fired boilers or...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Petitions Petitioning state Named source categories Connecticut Fossil fuel-fired boilers or other indirect.... New Hampshire Fossil fuel-fired indirect heat exchange combustion units and fossil fuel-fired electric generating facilities which emit ten tons of NOX or more per day. New York Fossil fuel-fired boilers or...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Petitions Petitioning state Named source categories Connecticut Fossil fuel-fired boilers or other indirect.... New Hampshire Fossil fuel-fired indirect heat exchange combustion units and fossil fuel-fired electric generating facilities which emit ten tons of NOX or more per day. New York Fossil fuel-fired boilers or...
Code of Federal Regulations, 2014 CFR
2014-07-01
... subcategory . . . You must meet the following . . . 1. Existing or new coal-fired, new biomass-fired, or new... as specified in § 63.11223. 6. Existing biomass-fired boilers that do not meet the definition of... biennially as specified in § 63.11223. 7. New biomass-fired boilers that do not meet the definition of...
Code of Federal Regulations, 2013 CFR
2013-07-01
... subcategory . . . You must meet the following . . . 1. Existing or new coal-fired, new biomass-fired, or new... as specified in § 63.11223. 6. Existing biomass-fired boilers that do not meet the definition of... biennially as specified in § 63.11223. 7. New biomass-fired boilers that do not meet the definition of...
Economic Benefit of Coal Utilization/Conversion at Air Force Bases: Screening Study
1989-08-01
fire-tLbe) boilers that are small enough to be shipped by rail. The field-erected units are larger, water- tube boilers. The pulverized coal-fired and...circulating FBC boilers considered are field-erected, water- tube boilers. Pollution control technology costs were considered to a limited extent. All...Coal/H 0 mix (S/MBtu) = 3.00 OPTIONS Cal/oil mix (S/MBtu) 3.50 Soot blower multiplier = 0.0 Tube bank mod multiplier = 1.0 Primary fuel is 1 Bottom ash
Yang, Xiaoyang; Geng, Chunmei; Sun, Xuesong; Yang, Wen; Wang, Xinhua; Chen, Jianhua
2016-02-01
Polycyclic aromatic hydrocarbons (PAHs) are carcinogenic or mutagenic and are important toxic pollutants in the flue gas of boilers. Two industrial grade biomass boilers were selected to investigate the characteristics of particulate-bound PAHs: one biomass boiler retro-fitted from an oil boiler (BB1) and one specially designed (BB2) biomass boiler. One coal-fired boiler was also selected for comparison. By using a dilution tunnel system, particulate samples from boilers were collected and 10 PAH species were analyzed by gas chromatography-mass spectrometry (GC-MS). The total emission factors (EFs) of PAHs ranged from 0.0064 to 0.0380 mg/kg, with an average of 0.0225 mg/kg, for the biomass boiler emission samples. The total PAH EFs for the tested coal-fired boiler were 1.8 times lower than the average value of the biomass boilers. The PAH diagnostic ratios for wood pellets and straw pellets were similar. The ratio of indeno(1,2,3-cd)pyrene/[indeno(1,2,3-cd)pyrene+benzo(g,h,i)perylene] for the two biomass boilers was lower than those of the reference data for other burning devices, which can probably be used as an indicator to distinguish the emission of biomass boilers from that of industrial coal-fired boilers and residential stoves. The toxic potential of the emission from wood pellet burning was higher than that from straw pellet burning, however both of them were much lower than residential stove exhausts. Copyright © 2015. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Cioccolanti, L.; Arteconi, A.; Bartolini, C. M.; Polonara, F.
2017-11-01
Nowadays the thermal energy demand in the industrial sector is usually satisfied by means of fire tube boilers while electricity is supplied from the grid. Alternatively cogeneration units could be adopted for thermal and electrical energy self-production, whilst installing boilers only as back-up units. However, even when cogeneration is profitable, it is not widespread because industries are usually unwilling to accept cogeneration plants for reliability and high investment costs issues. In this work a system aimed at overcoming the above mentioned market difficulties is proposed. It consists of an innovative coupling of a combined heat and power unit with a modified fire tube boiler. In particular, a CFD analysis was carried out by the authors in order to address the most critical aspects related with the coupling of the two systems. More precisely, the following aspects were evaluated in detail: (i) pressure losses of the exhausts going from the prime mover to the boiler due to the sudden cross-section area variations; (ii) thermal power recoverable from the exhausts in the tubes of the boiler; (iii) dependence of the system on the final users’ specification.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Takano, Shin-Ichi; Kiga, Takashi; Miyamae, Shigehiro
1994-12-31
In some future, it is expected for Japanese power stations to be hard to get a high-grade coal like a bituminous coal. We conducted therefore pilot scale tests of pulverized blends of bituminous coal and anthracite using a 1.2MWt tunnel furnace in order to evaluate the applicability of the blends of bituminous coal and anthracite to conventional pulverized coal firing boilers. One kind of bituminous coal and two kinds of anthracite, one was of low ash content and another was of high ash content, were prepared for the test. Previously to pilot scale tests, coal properties and ash properties ofmore » the blends of bituminous coal and anthracite were analyzed to estimate the characteristics of combustion, ash deposition, and so on. In the test, we investigated the combustion efficiency, NOx emission, characteristics of ignition stability and grindability changing the blend rate of anthracite. Results of our study indicated that the critical restrictions on the blending rate of anthracite were unburnt carbon in fly ash and NOx emission as for coals tested. The acceptable limitation on blending rate of anthracite was 10 and 20%, respectively for two kinds of conventional pulverized coal fired boiler. Concerning to the grindability, it became worse with increasing the blending rate of anthracite from grindability test using a roller mill, while it became better estimating from HGI.« less
Code of Federal Regulations, 2010 CFR
2010-07-01
... combustion of fossil fuel in a utility boiler. Group 1 boiler means a tangentially fired boiler or a dry... (boiler information) of the Department of Energy's Form EIA-767 for 1995. Non-plug-in combustion controls...
Code of Federal Regulations, 2013 CFR
2013-07-01
... combustion of fossil fuel in a utility boiler. Group 1 boiler means a tangentially fired boiler or a dry... (boiler information) of the Department of Energy's Form EIA-767 for 1995. Non-plug-in combustion controls...
Code of Federal Regulations, 2014 CFR
2014-07-01
... combustion of fossil fuel in a utility boiler. Group 1 boiler means a tangentially fired boiler or a dry... (boiler information) of the Department of Energy's Form EIA-767 for 1995. Non-plug-in combustion controls...
Code of Federal Regulations, 2011 CFR
2011-07-01
... combustion of fossil fuel in a utility boiler. Group 1 boiler means a tangentially fired boiler or a dry... (boiler information) of the Department of Energy's Form EIA-767 for 1995. Non-plug-in combustion controls...
Code of Federal Regulations, 2012 CFR
2012-07-01
... combustion of fossil fuel in a utility boiler. Group 1 boiler means a tangentially fired boiler or a dry... (boiler information) of the Department of Energy's Form EIA-767 for 1995. Non-plug-in combustion controls...
NASA Astrophysics Data System (ADS)
Kumari, Amrita; Das, Suchandan Kumar; Srivastava, Prem Kumar
2016-04-01
Application of computational intelligence for predicting industrial processes has been in extensive use in various industrial sectors including power sector industry. An ANN model using multi-layer perceptron philosophy has been proposed in this paper to predict the deposition behaviors of oxide scale on waterwall tubes of a coal fired boiler. The input parameters comprises of boiler water chemistry and associated operating parameters, such as, pH, alkalinity, total dissolved solids, specific conductivity, iron and dissolved oxygen concentration of the feed water and local heat flux on boiler tube. An efficient gradient based network optimization algorithm has been employed to minimize neural predictions errors. Effects of heat flux, iron content, pH and the concentrations of total dissolved solids in feed water and other operating variables on the scale deposition behavior have been studied. It has been observed that heat flux, iron content and pH of the feed water have a relatively prime influence on the rate of oxide scale deposition in water walls of an Indian boiler. Reasonably good agreement between ANN model predictions and the measured values of oxide scale deposition rate has been observed which is corroborated by the regression fit between these values.
Increase of efficiency and reliability of liquid fuel combustion in small-sized boilers
NASA Astrophysics Data System (ADS)
Roslyakov, P. V.; Proskurin, Yu V.; Ionkin, I. L.
2017-11-01
One of the ways to increase the efficiency of using fuels is to create highly efficient domestic energy equipment, in particular small-sized hot-water boilers in autonomous heating systems. Increasing the efficiency of the boiler requires a reduction in the temperature of the flue gases leaving, which, in turn, can be achieved by installing additional heating surfaces. The purpose of this work was to determine the principal design solutions and to develop a draft design for a high-efficiency 3-MW hot-water boiler using crude oil as its main fuel. Ensuring a high efficiency of the boiler is realized through the use of an external remote economizer, which makes it possible to reduce the dimensions of the boiler, facilitate the layout of equipment in a limited size block-modular boiler house and virtually eliminate low-temperature corrosion of boiler heat exchange surfaces. In the article the variants of execution of the water boiler and remote economizer are considered and the preliminary design calculations of the remote economizer for various schemes of the boiler layout in the Boiler Designer software package are made. Based on the results of the studies, a scheme was chosen with a three-way boiler and a two-way remote economizer. The design of a three-way fire tube hot water boiler and an external economizer with an internal arrangement of the collectors, providing for its location above the boiler in a block-modular boiler house and providing access for servicing both a remote economizer and a hot water boiler, is proposed. Its mass-dimensional and design parameters are determined. In the software package Boiler Designer thermal, hydraulic and aerodynamic calculations of the developed fire tube boiler have been performed. Optimization of the boiler design was performed, providing the required 94% efficiency value for crude oil combustion. The description of the developed flue and fire-tube hot water boiler and the value of the main design and technical and economic parameters are given.
Li, Zhengqi; Ren, Feng; Chen, Zhichao; Liu, Guangkui; Xu, Zhenxing
2010-05-15
A new technique combining high boiler efficiency and low-NO(x) emissions was employed in a 300MWe down-fired boiler as an economical means to reduce NO(x) emissions in down-fired boilers burning low-volatile coals. Experiments were conducted on this boiler after the retrofit with measurements taken of gas temperature distributions along the primary air and coal mixture flows and in the furnace, furnace temperatures along the main axis and gas concentrations such as O(2), CO and NO(x) in the near-wall region. Data were compared with those obtained before the retrofit and verified that by applying the combined technique, gas temperature distributions in the furnace become more reasonable. Peak temperatures were lowered from the upper furnace to the lower furnace and flame stability was improved. Despite burning low-volatile coals, NO(x) emissions can be lowered by as much as 50% without increasing the levels of unburnt carbon in fly ash and reducing boiler thermal efficiency.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woerner, W.L.
1994-12-31
The steam production potential of older biomass-fired boilers currently in operation may be significantly increased through the application of a commercially available gasifier. A large percentage of boiler systems in lumber mills and similar applications were initially designed to generate steam through convection heat transfer, and have been horse power rated at approximately 7 to 10 square feet of heating surface to the horse power. This paper deals with the before and after performance characteristics of the first gasifier retrofit installation based on an AED designed unit currently commercially available.
Rajh, Boštjan; Yin, Chungen; Samec, Niko; Hriberšek, Matjaž; Kokalj, Filip; Zadravec, Matej
2018-07-15
Grate-fired boilers are commonly used to burn biomass/wastes for heat and power production. In spite of the recent breakthrough in integration of advanced secondary air systems in grate boilers, grate-firing technology needs to be advanced for higher efficiency and lower emissions. In this paper, innovative staging of combustion air and recycled flue gas in a 13 MW th waste wood-fired grate boiler is comprehensively studied based on a numerical model that has been previously validated. In particular, the effects of the jet momentum, position and orientation of the combustion air and recycled flue gas streams on in-furnace mixing, combustion and pollutant emissions from the boiler are examined. It is found that the optimized air and recycled flue gas jets remarkably enhance mixing and heat transfer, result in a more uniform temperature and velocity distribution, extend the residence time of the combustibles in the hot zone and improve burnout in the boiler. Optimizing the air and recycled flue gas jet configuration can reduce carbon monoxide emission from the boiler by up to 86%, from the current 41.0 ppm to 5.7 ppm. The findings of this study can serve as useful guidelines for novel design and optimization of the combustion air supply and flue gas recycling for grate boilers of this type. Copyright © 2018 Elsevier Ltd. All rights reserved.
Xue, Yifeng; Tian, Hezhong; Yan, Jing; Zhou, Zhen; Wang, Junling; Nie, Lei; Pan, Tao; Zhou, Junrui; Hua, Shenbing; Wang, Yong; Wu, Xiaoqing
2016-06-01
Coal-fired combustion is recognized as a significant anthropogenic source of atmospheric compounds in Beijing, causing heavy air pollution events and associated deterioration in visibility. Obtaining an accurate understanding of the temporal trends and spatial variation characteristics of emissions from coal-fired industrial combustion is essential for predicting air quality changes and evaluating the effectiveness of current control measures. In this study, an integrated emission inventory of primary air pollutants emitted from coal-fired industrial boilers in Beijing is developed for the period of 2007-2013 using a technology-based approach. Future emission trends are projected through 2030 based on current energy-related and emission control policies. Our analysis shows that there is a general downward trend in primary air pollutants emissions because of the implementation of stricter local emission standards and the promotion by the Beijing municipal government of converting from coal-fired industrial boilers to gas-fired boilers. However, the ratio of coal consumed by industrial boilers to total coal consumption has been increasing, raising concerns about the further improvement of air quality in Beijing. Our estimates indicate that the total emissions of PM10, PM2.5, SO2, NOx, CO and VOCs from coal-fired industrial boilers in Beijing in 2013 are approximately 19,242 t, 13,345 t, 26,615 t, 22,965 t, 63,779 t and 1406 t, respectively. Under the current environmental policies and relevant energy savings and emission control plans, it may be possible to reduce NOx and other air pollutant emissions by 94% and 90% by 2030, respectively, if advanced flue gas purification technologies are implemented and coal is replaced with natural gas in the majority of existing boilers. Copyright © 2016 Elsevier Ltd. All rights reserved.
Research on the Application of Risk-based Inspection for the Boiler System in Power Plant
NASA Astrophysics Data System (ADS)
Li, Henan
2017-12-01
Power plant boiler is one of the three main equipment of coal-fired power plants, is very tall to the requirement of the safe and stable operation, in a significant role in the whole system of thermal power generation, a risk-based inspection is a kind of pursuit of security and economy of unified system management idea and method, can effectively evaluate equipment risk and reduce the operational cost.
Feasibility of a small central cogenerated energy facility: Energy management memorandum
NASA Astrophysics Data System (ADS)
Porter, R. N.
1982-10-01
The thermal economic feasibility of a small cogenerated energy facility designed to serve several industries in the Stockyards area was investigated. Cogeneration options included two dual fuel diesels and two gas turbines, all with waste heat boilers, and five fired boilers. Fuels included natural gas, and for the fired boiler cases, also low sulphur coal and municipal refuse. For coal and refuse, the option of steam only without cogeneration was also assessed. The fired boiler cogeneration systems employed back pressure steam turbines. The refuse fired cases utilized electrical capacities, 8500 to 52,400 lbm/hr and 0 to 9.9 MW (e), respectively. Deficient steam was assumed generated independently in existing equipment. Excess electrical power over that which was displaced was sold to Commonwealth Edison Company under PURPA (Public Utility Regulatory Policies Act). The facility was operated by a mutually owned corporation formed by the cogenerated power users.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jianzhong, L.; Xiang, Z.; Junhu, Z.
1999-07-01
The No.2 unit (670/H, 200MW) at Hebi Wanhe Power Generation C o. Ltd., was put into use in 1992. This is a coal-fired boiler with tangential fired method. The design coal is Hebi lean coal. To stabilize the combustion without oil at low load, eight original designed burners placed to No. 2 and 3 level on the No.2 boiler were replaced with the controllable pulverized rich/lean ones developed by the Institute for Thermal Power Engineering (ITPE) of Zhejiang University. The practice of successive operation shows that stable combustion can be achieved at 50% load without support oil, even at 45%more » load. The combustible matter in fly ash decreased to 1.12% and 1.17% from 1.83% and 1.32%, respectively at full load (200MW) and half load (100MW). The application has obvious economic benefits.« less
PILOT SCALE PROCESS EVALUATION OF REBURNING FOR IN-FURNACE NOX REDUCTION
The report gives results of coal and natural gas reburning application tests to a pilot scale 3.0 MWt furnace to provide the scaling information required for commercial application of reburning to pulverized-coal-fired boilers. Initial parametric studies had been conducted in a 2...
NASA Technical Reports Server (NTRS)
Knightly, W. F.
1980-01-01
Computer generated data on the performance of the cogeneration energy conversion system are presented. Performance parameters included fuel consumption and savings, capital costs, economics, and emissions of residual fired process boilers.
40 CFR Table 1 to Subpart Jjjjjj... - Emission Limits
Code of Federal Regulations, 2012 CFR
2012-07-01
... percent oxygen. 3. New biomass-fired boiler with heat input capacity of 30 million Btu per hour or greater a. Particulate Matter 0.03 lb per MMBtu of heat input. 4. New biomass fired boiler with heat input...
40 CFR Table 1 to Subpart Jjjjjj... - Emission Limits
Code of Federal Regulations, 2011 CFR
2011-07-01
... percent oxygen. 3. New biomass-fired boiler with heat input capacity of 30 million Btu per hour or greater a. Particulate Matter 0.03 lb per MMBtu of heat input. 4. New biomass fired boiler with heat input...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Units With Group 1 or Cell Burner Boilers A Appendix A to Part 76 Protection of Environment... 1 or Cell Burner Boilers Table 1—Phase I Tangentially Fired Units State Plant Unit Operator ALABAMA... TOWER 9 CEN ILLINOIS PUB SER. INDIANA CULLEY 2 STHERN IND GAS & EL. INDIANA CULLEY 3 STHERN IND GAS & EL...
[Emission characteristics of PM10 from coal-fired industrial boiler].
Li, Chao; Li, Xing-Hua; Duan, Lei; Zhao, Meng; Duan, Jing-Chun; Hao, Ji-Ming
2009-03-15
Through ELPI (electrical low-pressure impactor) based dilution sampling system, the emission characteristics of PM10 and PM2.5 was studied experimentally at the inlet and outlet of dust catchers at eight different coal-fired industrial boilers. Results showed that a peak existed at around 0.12-0.20 microm of particle size for both number size distribution and mass size distribution of PM10 emitted from most of the boilers. Chemical composition analysis indicated that PM2.5 was largely composed of organic carbon, elementary carbon, and sulfate, with mass fraction of 3.7%-21.4%, 4.2%-24.6%, and 1.5%-55.2% respectively. Emission factors of PM10 and PM2.5 measured were 0.13-0.65 kg x t(-1) and 0.08-0.49 kg x t(-1) respectively for grate boiler using raw coal, and 0.24 kg x t(-1) and 0.22 kg x t(-1) for chain-grate boiler using briquette. In comparison, the PM2.5 emission factor of fluidized bed boiler is 1.14 kg x t(-1), much her than that of grate boiler. Due to high coal consumption and low efficiency of dust separator, coal-fired industrial boiler may become the most important source of PM10, and should be preferentially controlled in China.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired means...) If a State elects to impose control measures on fossil fuel-fired non-EGUs that are boilers or... chapter. (ii) If the SIP revision contains measures to control fossil fuel-fired non-EGUs that are boilers...
Code of Federal Regulations, 2014 CFR
2014-07-01
..., or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired means...) If a State elects to impose control measures on fossil fuel-fired non-EGUs that are boilers or... chapter. (ii) If the SIP revision contains measures to control fossil fuel-fired non-EGUs that are boilers...
Code of Federal Regulations, 2010 CFR
2010-07-01
..., or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired means...) If a State elects to impose control measures on fossil fuel-fired non-EGUs that are boilers or... chapter. (ii) If the SIP revision contains measures to control fossil fuel-fired non-EGUs that are boilers...
Code of Federal Regulations, 2012 CFR
2012-07-01
..., or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired means...) If a State elects to impose control measures on fossil fuel-fired non-EGUs that are boilers or... chapter. (ii) If the SIP revision contains measures to control fossil fuel-fired non-EGUs that are boilers...
Code of Federal Regulations, 2011 CFR
2011-07-01
..., or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired means...) If a State elects to impose control measures on fossil fuel-fired non-EGUs that are boilers or... chapter. (ii) If the SIP revision contains measures to control fossil fuel-fired non-EGUs that are boilers...
Emissions During Co-Firing of RDF-5 with Coal in a 22 t/h Steam Bubbling Fluidized Bed Boiler
NASA Astrophysics Data System (ADS)
Wan, Hou-Peng; Chen, Jia-Yuan; Juch, Ching-I.; Chang, Ying-Hsi; Lee, Hom-Ti
The co-firing of biomass and fossil fuel in the same power plant is one of the most important issues when promoting the utilization of renewable energy in the world. Recently, the co-firing of coal together with biomass fuel, such as "densified refuse derived fuel" (d-RDF or RDF-5) or RPF (refuse paper & plastic fuel) from waste, has been considered as an environmentally sound and economical approach to both waste remediation and energy production in the world. Because of itscomplex characteristics when compared to fossil fuel, potential problems, such as combustion system stability, the corrosion of heat transfer tubes, the qualities of the ash, and the emissionof pollutants, are major concerns when co-firing the biomass fuel with fossil fuel in a traditional boiler. In this study, co-firing of coal with RDF-5 was conducted in a 22t/h bubbling fluidized bed (BFB) steam boiler to investigate the feasibility of utilizing RDF-5 as a sustainable fuels in a commercial coal-fired steam BFB boiler. The properties of the fly ash, bottom ash, and the emission of pollutants are analyzed and discussed in this study.
The report gives results of measurements of nitrous oxide (N2O) emissions from coal-fired utility boilers at three electric power generating stations. Six units were tested, two at each site, including sizes ranging from 165 to 700 MW. Several manufacturers and boiler firing type...
NOX EMISSION CONTROL OPTIONS FOR COAL-FIRED ELECTRIC UTILITY BOILERS
The paper reviews NOx control options for coal-fired electric utility boilers. (NOTE: Acid Rain NOx regulations, the Ozone Transport Commission's NOx Budget Program, revision of the New Source Performance Standards (NSPS) for NOx emissions from utility sources, and Ozone Transpor...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Boilers. 56.13030 Section 56.13030 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Compressed Air and Boilers § 56.13030 Boilers. (a) Fired pressure vessels (boiler...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Boilers. 56.13030 Section 56.13030 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Compressed Air and Boilers § 56.13030 Boilers. (a) Fired pressure vessels (boiler...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Boilers. 56.13030 Section 56.13030 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Compressed Air and Boilers § 56.13030 Boilers. (a) Fired pressure vessels (boiler...
SUMMARY REPORT CONTROL OF NOX EMISSIONS BY REBURNING
This report covers NOx control employing reburning technology: A new, effective method of controlling NOx emissions from a wide range of stationary combustion sources including large, coal-fired, utility boilers. Although reburning potentially is applicable ...
MENU OF NOX EMISSION CONTROL OPTIONS FOR COAL-FIRED ELECTRIC UTILITY BOILERS
The paper reviews NOx control options for coal-fired electric utility boilers. (NOTE: Acid Rain NOx regulations, the Ozone Transport Commission's NOx Budget Program, revision of the New Source Performance Standards (NSPS) for NOx emissions from utility sources, and Ozone Transpor...
DEVELOPMENT AND DEMONSTRATION OF NOVEL LOW-NOx BURNERS IN THE STEEL INDUSTRY
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cygan, David
Gas Technology Institute (GTI), together with Hamworthy Peabody Combustion Incorporated (formerly Peabody Engineering Corporation), the University of Utah, and Far West Electrochemical have developed and demonstrated an innovative combustion system suitable for natural gas and coke-oven gas firing within the steel industry. The combustion system is a simple, low-cost, energy-efficient burner that can reduce NOx by more than 75%. The U.S. steel industry needs to address NOx control at its steelmaking facilities. A significant part of NOx emissions comes from gas-fired boilers. In steel plants, byproduct gases – blast furnace gas (BFG) and coke-oven gas (COG) – are widely usedmore » together with natural gas to fire furnaces and boilers. In steel plants, natural gas can be fired together with BFG and COG, but, typically, the addition of natural gas raises NOx emissions, which can already be high because of residual fuel-bound nitrogen in COG. The Project Team has applied its expertise in low-NOx burners to lower NOx levels for these applications by combining advanced burner geometry and combustion staging with control strategies tailored to mixtures of natural gas and byproduct fuel gases. These methods reduce all varieties of NOx – thermal NOx produced by high flame temperatures, prompt NOx produced by complex chain reactions involving radical hydrocarbon species and NOx from fuel-bound nitrogen compounds such as ammonia found in COG. The Project Team has expanded GTI’s highly successful low-NOx forced internal recirculation (FIR) burner, previously developed for natural gas-fired boilers, into facilities that utilize BFG and COG. For natural gas firing, these burners have been shown to reduce NOx emissions from typical uncontrolled levels of 80-100 vppm to single-digit levels (9 vppm). This is done without the energy efficiency penalties incurred by alternative NOx control methods, such as external flue gas recirculation (FGR), water injection, and selective non-catalytic reduction. The FIR burner was previously demonstrated on firetube and watertube boilers, and these units are still operating at several industrial and commercial boiler sites in sizes ranging from 2.5 to 60 million Btu/h. This report covers the development of an innovative combustion system suitable for natural gas or coke-oven gas firing within the steel industry. The prototype FIR burner was evaluated on a 20 million Btu/h watertube boiler. Acceptable burner performance was obtained when firing natural gas and simulated coke-oven gas doped with ammonia. The laboratory data reveals a direct relationship between NOx formation and the ammonia concentration in the fuel. In addition, NOx formation increases as the primary stoichiometric ratio (PSR) increases. Representative ammonia concentrations, as documented in the steel industry, ranged from 200 to 500 vppm. When the laboratory burner/boiler was operated with 500 vppm ammonia in the fuel, NOx emissions ranged from 50 to 75 vppm. This, conservatively, is 75% less than state-of-the-art burner performance. When the burner is operated with 200 vppm ammonia in the fuel, the corresponding NOx emissions would range from 30 to 45 vppm, 84% less than present burner technology. During field evaluation on a 174 million Btu/h industrial prototype burner both natural gas and actual COG from on-site generation were tested. Despite the elevated hydrogen cyanide and ammonia content in the COG throughout the test program, the FIR burner showed an improvement over baseline emissions. At full load; 167 million Btu/h, NOx emissions were relatively low at 169 vppm. This represents a 30% reduction compared to baseline emissions not accounting for the higher hydrogen cyanide content in the COG. CO emissions remained below 20 vppm and were stable across the firing range. This represents a 68% reduction compared to baseline CO emissions. When firing natural gas, emissions were stable as firing rate increased over the range. At low fire; 45 million Btu/h, NOx emissions where 33 vppm and increased at full load; 144 million Btu/h, to 49 vppm. CO emissions fluctuated with the oxygen content and remained below 135 vppm during all tests. The boiler’s maximum output was not achieved due to a limitation dictated by the host site natural gas supply. The FIR burner benefits the public by simultaneously addressing the problems of air pollution and energy conservation through a low-NOx combustion technology that does not increase energy consumption. Continuing activities include the negotiation of a license with Hamworthy Peabody Combustion, Incorporated (Hamworthy Peabody) to commercialize the FIR burner for steel industry applications. Hamworthy Peabody is one of the largest U.S. manufacturers of combustion equipment for boilers in the Steel Industry, and has stated their intention to commercialize the FIR burner.« less
NATURAL GAS REBURNING FOR NOX CONTROL ON A CYCLONE-FIRED BOILER
The paper discusses natural gas reburning (fuel staging) for nitrogen oxide (NOx) control on a cyclone-fired boiler. eburning is an in-furnace NOx combustion modification technology that has been shown to reduce NOx by 50-60%. eburning is accomplished by injecting fuel downstream...
The report summarizes activities conducted and results achieved in an EPA-sponsored program to demonstrate Limestone Injection Multistage Burner (LIMB) technology on a tangentially fired coal-burning utility boiler, Virginia Power's 180-MWe Yorktown Unit No. 2. his successfully d...
11. Interior detail, Boiler Room, fire door to the adjacent ...
11. Interior detail, Boiler Room, fire door to the adjacent Blacksmith Shop, Roundhouse Machine Shop Extension, Southern Pacific Railroad Carlin Shops, view to southwest (90mm lens). - Southern Pacific Railroad, Carlin Shops, Roundhouse Machine Shop Extension, Foot of Sixth Street, Carlin, Elko County, NV
Code of Federal Regulations, 2011 CFR
2011-07-01
.... Fossil fuel means natural gas, petroleum, coal, or any form of solid, liquid, or gaseous fuel derived... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... any other fuel. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil...
Code of Federal Regulations, 2012 CFR
2012-07-01
... products), and landscape or right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel... unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine... limitation for the source for such control period. Fossil fuel means— (1) Natural gas, petroleum, coal, or...
Code of Federal Regulations, 2013 CFR
2013-07-01
... products), and landscape or right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel... unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine... limitation for the source for such control period. Fossil fuel means— (1) Natural gas, petroleum, coal, or...
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Fossil fuel means natural gas, petroleum, coal, or any form of solid, liquid, or gaseous fuel derived... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... any other fuel. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil...
Code of Federal Regulations, 2014 CFR
2014-07-01
.... Fossil fuel means natural gas, petroleum, coal, or any form of solid, liquid, or gaseous fuel derived... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... any other fuel. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil...
Code of Federal Regulations, 2010 CFR
2010-07-01
.... Fossil fuel means natural gas, petroleum, coal, or any form of solid, liquid, or gaseous fuel derived... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... any other fuel. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil...
Code of Federal Regulations, 2014 CFR
2014-07-01
... products), and landscape or right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel... unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine... limitation for the source for such control period. Fossil fuel means— (1) Natural gas, petroleum, coal, or...
Code of Federal Regulations, 2013 CFR
2013-07-01
.... Fossil fuel means natural gas, petroleum, coal, or any form of solid, liquid, or gaseous fuel derived... trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used to produce heat and... any other fuel. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil...
CONTROL OF NOX EMISSIONS FROM U.S. COAL-FIRED ELECTRIC UTILITY BOILERS
The paper discusses the control of nitrogen oxide (NOx) emissions from U.S. coal-fired electric utility boilers. (NOTE: In general, NOx control technologies are categorized as being either primary or secondary control technologies. Primary technologies reduce the amount of NOx pr...
SOURCE SAMPLING FINE PARTICULATE MATTER: WOOD-FIRED INDUSTRIAL BOILER
The report provides a profile for a wood-fired industrial boiler equipped with a multistage electrostatic precipitator control device. Along with the profile of emissions of fine particulate matter of aerodynamic diameter of 2.5 micrometers or less (PM-2.5), data are also provide...
9. RW Meyer Sugar Mill: 18761889. Locomotivetype, firetube, portable boiler, ...
9. RW Meyer Sugar Mill: 1876-1889. Locomotive-type, fire-tube, portable boiler, No. 1 model. Manufactured by Ames Iron Works, Oswego, New York, 1879. 120 lbs/sq. inch working pressure, 66 sq. ft. heating surface in tubes. View: from side. The boiler provided steam for steam engine which in turn powered the mill's centrifugals. The section on the left side included the firebox with its surrounding water-legs. The fluted chimney-type structure is the steam port, safety valve, and whistle. Column projecting from side was part of steam pressure and water gauge. Pipe running above boiler carried steam to the engine. Pipe running below boiler provided the boiler feed-water. Cylindrical section included 22 fire-tube surrounded by water. The far right ... - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI
NASA Astrophysics Data System (ADS)
E. Romero, Carlos; De Saro, Robert
Coal is a non-uniform material with large inherent variability in composition, and other important properties, such as calorific value and ash fusion temperature. This quality variability is very important when coal is used as fuel in steam generators, since it affects boiler operation and control, maintenance and availability, and the extent and treatment of environmental pollution associated with coal combustion. On-line/in situ monitoring of coal before is fed into a boiler is a necessity. A very few analytical techniques like X-ray fluorescence and prompt gamma neutron activation analysis are available commercially with enough speed and sophistication of data collection for continuous coal monitoring. However, there is still a need for a better on-line/in situ technique that has higher selectivity, sensitivity, accuracy and precision, and that is safer and has a lower installation and operating costs than the other options. Laser induced breakdown spectroscopy (LIBS) is ideal for coal monitoring in boiler applications as it need no sample preparation, it is accurate and precise it is fast, and it can detect all of the elements of concern to the coal-fired boiler industry. LIBS data can also be adapted with advanced data processing techniques to provide real-time information required by boiler operators nowadays. This chapter summarizes development of LIBS for on-line/in situ coal applications in utility boilers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sorge, J.N.; Larrimore, C.L.; Slatsky, M.D.
1997-12-31
This paper discusses the technical progress of a US Department of Energy Innovative Clean Coal Technology project demonstrating advanced wall-fired combustion techniques for the reduction of nitrogen oxide (NOx) emissions from coal-fired boilers. The primary objectives of the demonstration is to determine the long-term NOx reduction performance of advanced overfire air (AOFA), low NOx burners (LNB), and advanced digital control optimization methodologies applied in a stepwise fashion to a 500 MW boiler. The focus of this paper is to report (1) on the installation of three on-line carbon-in-ash monitors and (2) the design and results to date from the advancedmore » digital control/optimization phase of the project.« less
The report gives results of an evaluation of the effectiveness of combustion-type fuel oil additives to reduce emissions and increase efficiency in a 50-bhp (500 kw) commercial oil-fired packaged boiler. Most additive evaluation runs were made during continuous firing, constant-l...
A FIELD TEST USING COAL:DRDF BLENDS IN SPREADER STOKER-FIRED BOILERS
This program was conducted to characterize and demonstrate the technical, economic, and environmental feasibility of combustion densified forms of refuse derived fuel (dRDF) blended with coal in spreader stoker-fired boilers. A total of 258.5 Mg (285 tons) of pelletized 1/2-inch-...
PROTOTYPE SCALE TESTING OF LIMB TECHNOLOGY FOR A PULVERIZED-COAL-FIRED BOILER
The report summarizes results of an evaluation of furnace sorbent injection (FSI) to control sulfur dioxide (SO2) emissions from coal-fired utility boilers. (NOTE: FSI of calcium-based sorbents has shown promise as a moderate SO2 removal technology.) The Electric Power Research I...
The report gives results of the full-scale demonstration of Limestone Injection Multistage Burner (LIMB) technology on the coal-fired, 105 MW, Unit 4 boiler at Ohio Edison's Edgewater Station. eveloped as a technology aimed at moderate levels of sulfur dioxide (SO2) and nitrogen ...
Code of Federal Regulations, 2014 CFR
2014-07-01
... products), and landscape or right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel..., fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine: (1) Having equipment used... that any portion of a ton of excess emissions shall be treated as one ton of excess emissions. Fossil...
Code of Federal Regulations, 2013 CFR
2013-07-01
... products), and landscape or right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel..., fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine: (1) Having equipment used... that any portion of a ton of excess emissions shall be treated as one ton of excess emissions. Fossil...
Code of Federal Regulations, 2012 CFR
2012-07-01
... products), and landscape or right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel..., fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine: (1) Having equipment used... that any portion of a ton of excess emissions shall be treated as one ton of excess emissions. Fossil...
Code of Federal Regulations, 2010 CFR
2010-07-01
... products), and landscape or right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel..., fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine: (1) Having equipment used... that any portion of a ton of excess emissions shall be treated as one ton of excess emissions. Fossil...
Code of Federal Regulations, 2011 CFR
2011-07-01
... products), and landscape or right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel..., fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine: (1) Having equipment used... that any portion of a ton of excess emissions shall be treated as one ton of excess emissions. Fossil...
NOVEL ECONOMICAL HG(0) OXIDATION REAGENT FOR MERCURY EMISSIONS CONTROL FROM COAL-FIRED BOILERS
The authors have developed a novel economical additive for elemental mercury (Hg0) removal from coal-fired boilers. The oxidation reagent was rigorously tested in a lab-scale fixed-bed column with the Norit America's FGD activated carbon (DOE's benchmark sorbent) in a typical PRB...
The paper describes retrofitting and testing a 590 kW (2 MBtu/hr), oil-fired, three-pass, fire-tube package boiler with a combined selective noncatalytic reduction (SNCR) and selective catalytic reduction (SCR) system. The system demonstrated 85% nitrogen oxides (NOx) reduction w...
40 CFR 49.124 - Rule for limiting visible emissions.
Code of Federal Regulations, 2012 CFR
2012-07-01
...% opacity limit. (3) The visible emissions from an oil-fired boiler or solid fuel-fired boiler that..., fuel, fuel oil, fugitive dust, gaseous fuel, grate cleaning, marine vessel, mobile sources, motor..., PM10, PM2.5, reference method, refuse, Regional Administrator, residual fuel oil, smudge pot, solid...
40 CFR 49.124 - Rule for limiting visible emissions.
Code of Federal Regulations, 2014 CFR
2014-07-01
...% opacity limit. (3) The visible emissions from an oil-fired boiler or solid fuel-fired boiler that..., fuel, fuel oil, fugitive dust, gaseous fuel, grate cleaning, marine vessel, mobile sources, motor..., PM10, PM2.5, reference method, refuse, Regional Administrator, residual fuel oil, smudge pot, solid...
NASA Astrophysics Data System (ADS)
Gu, Hui; Zhu, Hongxia; Cui, Yanfeng; Si, Fengqi; Xue, Rui; Xi, Han; Zhang, Jiayu
2018-06-01
An integrated combustion optimization scheme is proposed for the combined considering the restriction in coal-fired boiler combustion efficiency and outlet NOx emissions. Continuous attribute discretization and reduction techniques are handled as optimization preparation by E-Cluster and C_RED methods, in which the segmentation numbers don't need to be provided in advance and can be continuously adapted with data characters. In order to obtain results of multi-objections with clustering method for mixed data, a modified K-prototypes algorithm is then proposed. This algorithm can be divided into two stages as K-prototypes algorithm for clustering number self-adaptation and clustering for multi-objective optimization, respectively. Field tests were carried out at a 660 MW coal-fired boiler to provide real data as a case study for controllable attribute discretization and reduction in boiler system and obtaining optimization parameters considering [ maxηb, minyNOx ] multi-objective rule.
The report describes a demonstration of reburning on a cyclone-fired boiler. The project included a review of reburn technology, aerodynamic flow model testing, long-term load dispatch testing, and boiler tube wall thickness monitoring. The report also contains a description of O...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Boilers. 57.13030 Section 57.13030 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Compressed Air and Boilers § 57.13030 Boilers. (a) Fired pressure vessels ...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Boilers. 57.13030 Section 57.13030 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Compressed Air and Boilers § 57.13030 Boilers. (a) Fired pressure vessels ...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Boilers. 57.13030 Section 57.13030 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Compressed Air and Boilers § 57.13030 Boilers. (a) Fired pressure vessels ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1981-08-01
This report presents the results of tests for polynuclear aromatic hydrocarbons (PAH) and inorganic trace elements in the effluent of eleven coal stoker fired boilers. These data are part of a larger stoker test program whose main objective was to produce information which will increase the ability of the boiler manufacturers to design and fabricate stoker boilers that are an economical and environmentally satisfactory alternative to oil and gas-fired units. The objectives of the SASS testing portion of this program are to determine the organic and inorganic makeup of boiler emissions which cannot be detected by using the standard EPAmore » Method 5 train. SASS tests were conducted in accordance with EPA Level 1 guidelines. Twenty-three SASS tests were run on 11 different coal stoker fired boilers to determine emissions data for 74 inorganic trace elements and 21 PAHs. The emissions of most concern are the suspected carcinogens or the emissions with high probability of being carcinogens. The inorganic trace elements that were investigated and are listed as carcinogens and high probability carcinogens by the Office of Air Quality Planning and Standards are: arsenic, beryllium, cadmium, and nickel. The SASS emissions data are presented in three different sets of units: nonograms per joule of energy input, micrograms per dry standard cubic meter of flue gas sampled, and grams per kilograms of fuel input. To protect the interests of the host boiler facilities, each site has been given a letter designation. A complete description of each unit and all tests run at each site can be found in the corresponding site reports referenced at the end of this report. This report contains a description of the test equipment and procedures, analytical procedures, data reduction techniques, the test data, and a brief description of each facility tested and the coals fired. 4 figures, 16 tables.« less
Exergy analysis on industrial boiler energy conservation and emission evaluation applications
NASA Astrophysics Data System (ADS)
Li, Henan
2017-06-01
Industrial boiler is one of the most energy-consuming equipments in china, the annual consumption of energy accounts for about one-third of the national energy consumption. Industrial boilers in service at present have several severe problems such as small capacity, low efficiency, high energy consumption and causing severe pollution on environment. In recent years, our country in the big scope, long time serious fog weather, with coal-fired industrial boilers is closely related to the regional characteristics of high strength and low emissions [1]. The energy-efficient and emission-reducing of industry boiler is of great significance to improve China’s energy usage efficiency and environmental protection. Difference in thermal equilibrium theory is widely used in boiler design, exergy analysis method is established on the basis of the first law and second law of thermodynamics, by studying the cycle of the effect of energy conversion and utilization, to analyze its influencing factors, to reveal the exergy loss of location, distribution and size, find out the weak links, and a method of mining system of the boiler energy saving potential. Exergy analysis method is used for layer combustion boiler efficiency and pollutant emission characteristics analysis and evaluation, and can more objectively and accurately the energy conserving potential of the mining system of the boiler, find out the weak link of energy consumption, and improve equipment performance to improve the industrial boiler environmental friendliness.
Development of the Radiation Stabilized Distributed Flux Burner. Phase 1, final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sullivan, J.D.; Duret, M.J.
1997-06-01
The RSB was first developed for Thermally Enhanced Oil Recovery steamers which fire with a single 60 MMBtu/hr burner; the California Energy Commission and Chevron USA were involved in the burner development. The burner has also since found applications in refinery and chemical plant process heaters. All Phase I goals were successfully met: the RSB achieved sub-9 ppM NOx and sub-50 ppM CO emissions using high excess air, external flue gas recirculation (FGR), and fuel staging in the 3 MMBtu/hr laboratory watertube boiler. In a test in a 50,000 lb/hr oil field steamer with fuel staging, it consistently achieved sub-20more » ppM NOx and as low as 10 ppM NOx. With high CO{sub 2} casing gas in this steamer, simulating external FGR, sub-20 ppM NOx and as low as 5 ppM NOx were achieved. Burner material cost was reduced by 25% on a per Btu basis by increasing the effective surface firing rate at the burner; further reductions will occur in Phase II. The market for 30 ppM and 9 ppM low NOx burners has been identified as package boilers in the 50,000 to 250,000 lb/hr size range (the 30 ppM is for retrofit, the 9 ppM for the new boiler market). Alzeta and Babcock & Wilcox have teamed to sell both boiler retrofits and new boilers; they have identified boiler designs which use the compact flame shape of the RSB and can increase steam capacity while maintaining the same boiler footprint. Alzeta, Chevron, and B & W have teamed to identify sites to demonstrate the RSB in Phases II and III. In Phase II, the RSB will be demonstrated in a 100,000 lb/hr industrial watertube boiler.« less
NASA Astrophysics Data System (ADS)
Żymełka, Piotr; Nabagło, Daniel; Janda, Tomasz; Madejski, Paweł
2017-12-01
Balanced distribution of air in coal-fired boiler is one of the most important factors in the combustion process and is strongly connected to the overall system efficiency. Reliable and continuous information about combustion airflow and fuel rate is essential for achieving optimal stoichiometric ratio as well as efficient and safe operation of a boiler. Imbalances in air distribution result in reduced boiler efficiency, increased gas pollutant emission and operating problems, such as corrosion, slagging or fouling. Monitoring of air flow trends in boiler is an effective method for further analysis and can help to appoint important dependences and start optimization actions. Accurate real-time monitoring of the air distribution in boiler can bring economical, environmental and operational benefits. The paper presents a novel concept for online monitoring system of air distribution in coal-fired boiler based on real-time numerical calculations. The proposed mathematical model allows for identification of mass flow rates of secondary air to individual burners and to overfire air (OFA) nozzles. Numerical models of air and flue gas system were developed using software for power plant simulation. The correctness of the developed model was verified and validated with the reference measurement values. The presented numerical model for real-time monitoring of air distribution is capable of giving continuous determination of the complete air flows based on available digital communication system (DCS) data.
NASA Astrophysics Data System (ADS)
Ryabov, G. A.; Folomeev, O. M.; Litun, D. S.; Sankin, D. A.; Dmitryukova, I. G.
2009-01-01
The present state and development of circulating fluidized bed (CFB) technology around the world are briefly reviewed. Questions of increasing the capacity of single boiler units and raising the parameters of steam are discussed. CFB boilers for 225- and 330-MW power units are described and their parameters are estimated as applied to the conditions of firing different Russian fuels. Indicators characterizing CFB boilers and pulverized-coal boilers are given. Capital outlays and operational costs for new coal-fired units are compared, and the results from this comparison are used to show the field of the most promising use of the CFB technology during technical refitting of Russian thermal power stations.
Prospects for the development of coal-steam plants in Russia
NASA Astrophysics Data System (ADS)
Tumanovskii, A. G.
2017-06-01
Evaluation of the technical state of the modern coal-fired power plants and quality of coal consumed by Russian thermal power plants (TPP) is provided. Measures aimed at improving the economic and environmental performance of operating 150-800 MW coal power units are considered. Ways of efficient use of technical methods of NO x control and electrostatic precipitators' upgrade for improving the efficiency of ash trapping are summarized. Examples of turbine and boiler equipment efficiency upgrading through its deep modernization are presented. The necessity of the development and introduction of new technologies in the coal-fired power industry is shown. Basic technical requirements for a 660-800 MW power unit with the steam conditions of 28 MPa, 600/600°C are listed. Design solutions taking into account features of Russian coal combustion are considered. A field of application of circulating fluidized bed (CFB) boilers and their effectiveness are indicated. The results of development of a new generation coal-fired TPP, including a steam turbine with an increased efficiency of the compartments and disengaging clutch, an elevated steam conditions boiler, and a highly efficient NO x /SO2 and ash particles emission control system are provided. In this case, the resulting ash and slag are not to be sent to the ash dumps and are to be used to a maximum advantage. Technical solutions to improve the efficiency of coal gasification combined cycle plants (CCP) are considered. A trial plant based on a 16 MW gas turbine plant (GTP) and an air-blown gasifier is designed as a prototype of a high-power CCP. The necessity of a state-supported technical reequipment and development program of operating coal-fired power units, as well as putting into production of new generation coal-fired power plants, is noted.
NASA Astrophysics Data System (ADS)
Ying, Wu; Yong-lu, Zhong; Guo-mingi, Yin
2018-06-01
On account of nine commonly used coals in a Jiangxi Power Plant,two kinds of coal were selected to be applied in coal co-firing test through industrial analysis,elementary analysis and thermogravimetric analysis of coal.During the coal co-firing test,two load points were selected,three coal mixtures were prepared.Moreover,under each coal blending scheme, the optimal oxygen content was obtained by oxygen varying test. At last,by measuring the boiler efficiency and coal consumption of power supply in different coal co-firing schemes, the recommended coal co-firing scheme was obtained.
40 CFR 63.1206 - When and how must you comply with the standards and operating requirements?
Code of Federal Regulations, 2012 CFR
2012-07-01
.... (2) Compliance date for solid fuel boilers, liquid fuel boilers, and hydrochloric acid production... discharged and where fuels are normally fired. (i) Cement kilns that feed hazardous waste at a location other than the end where products are normally discharged and where fuels are normally fired must comply with...
ERIC Educational Resources Information Center
Department of Energy, Washington, DC.
This paper examines the environmental impacts of replacing the Bison, South Dakota School District's elementary and high school heating system consisting of oil-fired boilers, and supporting electrical components with a new coal-fired boiler and supporting control system piping. Various alternative systems are also examined, including purchasing a…
The paper presents estimates of performance levels and related costs associated with controlling mercury (Hg) emissions from coal-fired power plants using either powdered activated carbon (PAC) injection or multipollutant control in which Hg capture is enhanced in existing and ne...
Under the Clean Air Act Amendments of 1990, the Environmental Protection Agency has determined that regulation of mercury emissions from coal-fired power plants is appropriate and necessary. To aid in this determination, preliminary estimates of the performance and cost of powder...
[Emission characteristics of fine particles from grate firing boilers].
Wang, Shu-Xiao; Zhao, Xiu-Juan; Li, Xing-Hua; Wei, Wei; Hao, Ji-Ming
2009-04-15
Grate firing boilers are the main type of Chinese industrial boilers, which accounts for 85% of the industrial boilers and is one of the most important emission sources of primary air pollutants in China. In this study, five boilers in three cities were selected and tested to measure the emission characteristics of PM2.5, and gaseous pollutants were applied by a compact dilution sampling system, which was developed for this field study. Results showed that particles mass size distributions for the five industrial boilers presented single peak or double peak, former peaks near 0.14 microm and the later peaks after 1.0 microm; the cyclone dust remover and wet scrubber dust remover had effective removal efficiencies not only to PM2.5, but also to PM1.0; and under the condition of same control techniques, grate firing boiler with high capacity has less PM2.5 emission than the boiler with low capacity. In the PM2.5 collected from flue gases, SO4(2-) was the most abundant ion, accounted for 20%-40% of the PM2.5; and C was the most abundant element (7.5%-31.8%), followed by S (8.4%-18.7%). Carbon balance method was applied to calculate the emission factors of these pollutants. The emission factors of PM2.5, NO, and SO2 were in the range of 0.046-0.486 g x kg(-1), 1.63-2.47 g x kg(-1), 1.35-9.95 g x kg(-1) respectively. The results are useful for the emission inventory development of industrial boilers and the source analysis of PM2.5 in atmospheric environment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The PROJECT proposes to install a new TCS micronized coal-fired heating plant for the Produkcja I Hodowla Roslin Ogrodniczych (PHRO) Greenhouse Complex; Krzeszowice, Poland (about 20 miles west of Krakow). PHRO currently utilizes 14 heavy oil-fired boilers to produce heat for its greenhouse facilities and also home heating to several adjacent apartment housing complexes. The boilers currently burn a high-sulfur content heavy crude oil, called Mazute. For size orientation, the PHRO Greenhouse complex grows a variety of vegetables and flowers for the Southern Poland marketplace. The greenhouse area under glass is very large and equivalent to approximately 50 football fields.more » The new micronized coal fired boiler would: (1) provide a significant portion of the heat for PHRO and a portion of the adjacent apartment housing complexes, (2) dramatically reduce sulfur dioxide air pollution emissions, while satisfying new Polish air regulations, and (3) provide attractive savings to PHRO, based on the quantity of displaced oil. Currently, the Town of Krzeszowice is considering a district heating program that would replace some, or all, of the 40 existing small in-town heating boilers that presently burn high-sulfur content coal. Potentially the district heating system can be expanded and connected into the PHRO boiler network; so that, PHRO boilers can supply all, or a portion of, the Town`s heating demand. The new TCS micronized coal system could provide a portion of this demand.« less
Explosion in boiler closes Arkansas utility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-08-23
A major boiler explosion Aug. 11 that seriously injured one worker at the Independence Unit 2 coal-fired powerplant in Newark, Ark., caused extensive damage that will keep the plant closed for several months. The plant is owned by Arkansas Power Light Co., Little Rock. Officials are still trying to determine cause and are assessing damage, though they expect the boiler can be repaired. Etienne Senac, plant manager, says the explosion [open quotes]puffed out[close quotes] but did not rupture the 271-ft-tall boiler and also buckled several buck stays, which hold the boiler to a steel superstructure. The accident took place atmore » 8:30 a.m. as the 842-Mw unit was operating close to full capacity. Senac says the concussion knocked down workers standing 50 ft from the boiler. The explosion pushed ash and molten material out of the bottom of the unit, causing a small fire. One contract worker was seriously burned and hospitalized. Four AP L workers received minor burns.« less
A novel direct-fired porous-medium boiler
NASA Astrophysics Data System (ADS)
Prasartkaew, Boonrit
2018-01-01
Nowadays, power and heat generation systems pay an important role in all economic sectors. These systems are mainly based on combustion reaction and operated under the second law of thermodynamics. A conventional boilers, a main component of heat and power generators, have thermal efficiency in the range of 70 to 85%, mainly owing to they have flue gas heat loss. This paper proposes a novel type of boiler, called a Direct-fired Porous-medium Boiler (DPB). Due to being operated without flue gas heat loss, its thermal efficiency cloud be approximately close to 100%. The steam produced from the proposed boiler; however, is not pure water steam. It is the composite gases of steam and combustion-product-gases. This paper aims at presenting the working concept and reporting the experimental results on the performance of the proposed boiler. The experiments of various operating parameters were performed and collected data were used for the performance analysis. The experimental results demonstrated that the proposed boiler can be operated as well as the conceptual design and then it is promising. It can be possibly further developed to be a high efficiency boiler by means of reducing or suppressing the surface heat loss with better insulator and/or refractory lined.
Pre-fired, refractory block slag dams for wet bottom furnace floors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vihnicka, R.S.; Meskimen, R.L.
1998-12-31
Slagging (wet bottom), utility boilers count on a refractory coating over the furnace floor tube structure for protection from corrosion damage from both the harsh, hot gas atmosphere from the burning fuel and the acidic coal slag. To protect and extend the life of this protective refractory coating the boiler original equipment manufacturers (OEMs) utilized a water-cooled monkey ring or slag chill ring (typically a 6--8 inch high ring of small diameter tubes) surrounding the slag tap locations on most wet bottom furnace floors (both utility and package boilers). The old water-cooled tube ring was such a high maintenance item,more » however, that it`s use has been discontinued in all but the most extreme environments throughout both utility and industrial applications. Where the use of the ring was discontinued, there has been a corresponding shortening of life on the protective floor refractory coatings (high maintenance cost), further aggravated by recent OSHA restrictions limiting the use of chrome oxide refractory materials in these types of boilers. This paper describes the developmental process and the final resultant product (a non-watercooled, slag dam made from pre-fired refractory shapes), undertaken by the inventors. Derived operational benefits a concept 2 project, with NO{sub x} Title 4 and Title 1 significance (which is currently underway) will also be detailed.« less
Effect of Thermal Storage on the Performance of a Wood Pellet-fired Residential Boiler
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas, Butcher
Interest in the direct use of biomass for thermal applications as a renewable technology is increasing as is also focus on air pollutant emissions from these sources and methods to minimize the impact. This work has focused on wood pellet-fired residential boilers, which are the cleanest fuel in this category. In the residential application the load varies strongly over the course of a year and a high fraction of the load is typically under 15% of the maximum boiler capacity. Thermal storage can be used even with boilers which have modulation capacity typically to 30% of the boiler maximum. Onemore » common pellet boiler was tested at full load and also at the minimum load used in the U.S. certification testing (15%). In these tests the load was steady over the test period. Testing was also done with an emulated load profile for a home in Albany, N.Y. on a typical January, March, and April day. In this case the load imposed on the boiler varied hourly under computer control, based on the modeled load for the example case used. The boiler used has a nominal output of 25 kW and a common mixed hardwood/softwood commercial pellet was used. Moisture content was 3.77%. A dilution tunnel approach was used for the measurement of particulate emissions, in accordance with U.S. certification testing requirements. The test results showed that the use of storage strongly reduces cycling rates under part load conditions. The transients which occur as these boilers cycle contribute to increased particulate emissions and reduced efficiency. The time period of a full cycle at a given load condition can be increased by increasing the storage tank volume and/or increasing the control differential range. It was shown that increasing the period strongly increased the measured efficiency and reduced the particulate emission (relative to the no storage case). The impact was most significant at the low load levels. Storage tank heat loss is shown to be a significant factor in thermal efficiency, particularly at low load. Different methods to measure this heat loss were explored. For one of the tanks evaluated the efficiency loss at the 15% load point was found to be as high as 7.9%. Where storage is used good insulation on the tank, insulation on the piping, and attention to fittings are recommended.« less
NASA Astrophysics Data System (ADS)
Chatha, Sukhpal Singh; Sidhu, Hazoor S.; Sidhu, Buta S.
2013-06-01
Ni-20Cr coating was deposited on T91 boiler tube steel by high-velocity oxy-fuel (HVOF) process to enhance high-temperature oxidation resistance. High-temperature performance of bare, as well as HVOF-coated steel specimens was evaluated for 1500 h under in the platen superheater zone of coal-fired boiler, where the temperature was around 900 °C. Experiments were carried out for 15 cycles, each of 100-h duration followed by 1-h cooling at ambient temperature. The extent of degradation of the specimens was assessed by the thickness loss and depth of internal corrosion attack. Ni-20Cr-coated steel performed better than the uncoated steel in actual boiler environment. The improved degradation resistance of Ni-20Cr coating can be attributed to the presence of Cr2O3 in the top oxide scale and dense microstructure.
Thermal energy storage for power generation applications
NASA Astrophysics Data System (ADS)
Drost, M. K.; Antoniak, Zen I.; Brown, D. R.
1990-03-01
Studies strongly indicate that the United States will face widespread electrical power constraints in the 1990s. In many cases, the demand for increased power will occur during peak and intermediate demand periods. While natural gas is currently plentiful and economically attractive for meeting peak and intermediate loads, the development of a coal-fired peaking option would give utilities insurance against unexpected supply shortages or cost increases. This paper discusses a conceptual evaluation of using thermal energy storage (TES) to improve the economics of coal-fired peak and intermediate load power generation. The use of TES can substantially improve the economic attractiveness of meeting peak and intermediate loads with coal-fired power generation. In this case, conventional pulverized coal combustion equipment is continuously operated to heat molten nitrate salt, which is then stored. During peak demand periods, hot salt is withdrawn from storage and used to generate steam for a Rankine steam power cycle. This allows the coal-fired salt heater to be approximately one-third the size of a coal-fired boiler in a conventional cycling plant. The general impact is to decouple the generation of thermal energy from its conversion to electricity. The present study compares a conventional cycling pulverized coal-fired power plant to a pulverized coal-fired plant using nitrate salt TES. The study demonstrates that a coal-fired salt heater is technically feasible and should be less expensive than a similar coal-fired boiler. The results show the use of nitrate salt TES reduced the levelized cost of power by between 5 and 24 percent, depending on the operating schedule.
Performance of casting aluminum-silicon alloy condensing heating exchanger for gas-fired boiler
NASA Astrophysics Data System (ADS)
Cao, Weixue; Liu, Fengguo; You, Xue-yi
2018-07-01
Condensing gas boilers are widely used due to their high heat efficiency, which comes from their ability to use the recoverable sensible heat and latent heat in flue gas. The condensed water of the boiler exhaust has strong corrosion effect on the heat exchanger, which restricts the further application of the condensing gas boiler. In recent years, a casting aluminum-silicon alloy (CASA), which boasts good anti-corrosion properties, has been introduced to condensing hot water boilers. In this paper, the heat transfer performance, CO and NOx emission concentrations and CASA corrosion resistance of a heat exchanger are studied by an efficiency bench test of the gas-fired boiler. The experimental results are compared with heat exchangers produced by Honeywell and Beka. The results show that the excess air coefficient has a significant effect on the heat efficiency and CO and NOx emission of the CASA water heater. When the excess air coefficient of the CASA gas boiler is 1.3, the CO and NOx emission concentration of the flue gas satisfies the design requirements, and the heat efficiency of water heater is 90.8%. In addition, with the increase of heat load rate, the heat transfer coefficient of the heat exchanger and the heat efficiency of the water heater are increased. However, when the heat load rate is at 90%, the NOx emission in the exhaust gas is the highest. Furthermore, when the temperature of flue gas is below 57 °C, the condensation of water vapor occurs, and the pH of condensed water is in the 2.5 5.5 range. The study shows that CASA water heater has good corrosion resistance and a high heat efficiency of 88%. Compared with the heat exchangers produced by Honeywell and Beka, there is still much work to do in optimizing and improving the water heater.
Performance of casting aluminum-silicon alloy condensing heating exchanger for gas-fired boiler
NASA Astrophysics Data System (ADS)
Cao, Weixue; Liu, Fengguo; You, Xue-yi
2018-01-01
Condensing gas boilers are widely used due to their high heat efficiency, which comes from their ability to use the recoverable sensible heat and latent heat in flue gas. The condensed water of the boiler exhaust has strong corrosion effect on the heat exchanger, which restricts the further application of the condensing gas boiler. In recent years, a casting aluminum-silicon alloy (CASA), which boasts good anti-corrosion properties, has been introduced to condensing hot water boilers. In this paper, the heat transfer performance, CO and NOx emission concentrations and CASA corrosion resistance of a heat exchanger are studied by an efficiency bench test of the gas-fired boiler. The experimental results are compared with heat exchangers produced by Honeywell and Beka. The results show that the excess air coefficient has a significant effect on the heat efficiency and CO and NOx emission of the CASA water heater. When the excess air coefficient of the CASA gas boiler is 1.3, the CO and NOx emission concentration of the flue gas satisfies the design requirements, and the heat efficiency of water heater is 90.8%. In addition, with the increase of heat load rate, the heat transfer coefficient of the heat exchanger and the heat efficiency of the water heater are increased. However, when the heat load rate is at 90%, the NOx emission in the exhaust gas is the highest. Furthermore, when the temperature of flue gas is below 57 °C, the condensation of water vapor occurs, and the pH of condensed water is in the 2.5 5.5 range. The study shows that CASA water heater has good corrosion resistance and a high heat efficiency of 88%. Compared with the heat exchangers produced by Honeywell and Beka, there is still much work to do in optimizing and improving the water heater.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hart, D.; Lewis, R.; Tobiasz, R.
1998-12-31
The composition and properties of ash formed during coal firing have a major impact on boiler performance. Higher ash content in the coal can mean higher costs associated with coal handling, transportation, ash removal and ash disposal along with higher costs due to the increased ash content`s deleterious effects on pulverizing, combustion and heat transfer. ABB C-E Services, Inc. has conducted research for many years on what might be done to minimize the adverse effects of ash on boiler performance. Recently, ABB C-E Services has studied the effects of firing system modifications on ash composition and properties and the effectmore » these firing system modifications have on overall furnace performance. The subject of this paper is the impact of the installation of the CFS Concentric Firing System on the propensity for boiler wall ash deposition. For this study, CFS yaw angles were varied and particle samples were collected at the waterwalls for the different yaw angles tested. These ash samples were analyzed for ash composition. The results showed that with a larger CFS yaw angle (the air stream directed more towards the boiler walls) the base/acid ratio, iron content and sulfur content of the particle samples collected at the waterwall were reduced. This effect is due to several contributing factors: (1) an oxidizing environment produced by injecting more air toward the walls; and (2) an aerodynamic change which impacts the particle combustion time/temperature history.« less
Millwright Apprenticeship. Related Training Modules. 7.1-7.9 Boilers.
ERIC Educational Resources Information Center
Lane Community Coll., Eugene, OR.
This packet, part of the instructional materials for the Oregon apprenticeship program for millwright training, contains nine modules covering boilers. The modules provide information on the following topics: fire and water tube types of boilers, construction, fittings, operation, cleaning, heat recovery systems, instruments and controls, and…
Applications of selective catalytic reduction (SCR) systems and wet flue gas desulfurization (FGD) scrubbers on coal-fired boilers have led to substantial reductions in emissions of nitrogen oxides (NOX) and sulfur dioxide (SO2). However, observations of pilot- and full-scale tes...
Reifman, Jaques; Feldman, Earl E.; Wei, Thomas Y. C.; Glickert, Roger W.
2003-01-01
The control of emissions from fossil-fired boilers wherein an injection of substances above the primary combustion zone employs multi-layer feedforward artificial neural networks for modeling static nonlinear relationships between the distribution of injected substances into the upper region of the furnace and the emissions exiting the furnace. Multivariable nonlinear constrained optimization algorithms use the mathematical expressions from the artificial neural networks to provide the optimal substance distribution that minimizes emission levels for a given total substance injection rate. Based upon the optimal operating conditions from the optimization algorithms, the incremental substance cost per unit of emissions reduction, and the open-market price per unit of emissions reduction, the intelligent emissions controller allows for the determination of whether it is more cost-effective to achieve additional increments in emission reduction through the injection of additional substance or through the purchase of emission credits on the open market. This is of particular interest to fossil-fired electrical power plant operators. The intelligent emission controller is particularly adapted for determining the economical control of such pollutants as oxides of nitrogen (NO.sub.x) and carbon monoxide (CO) emitted by fossil-fired boilers by the selective introduction of multiple inputs of substances (such as natural gas, ammonia, oil, water-oil emulsion, coal-water slurry and/or urea, and combinations of these substances) above the primary combustion zone of fossil-fired boilers.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-23
... boilers are small (less than 10 MMBtu/hr heat input) and are generally owned and operated by contractors... (> 5MMBtu/h) or five-year ( New boilers with heat input capacity greater than 10 million Btu per hour that... with heat input capacity greater than 10 million Btu per hour that are biomass-fired or oil-fired must...
Measurements of nitrous oxide emissions from P.F. fired power stations
NASA Astrophysics Data System (ADS)
Sloan, S. A.; Laird, C. K.
Nitrous oxide (N 2O) was measured in the flue gas from four wall-fired and three corner-fired 500 MW boilers, fitted with either conventional or low-NO x burners, at four C.E.G.B. power stations. Measurements were made both by on-line non-dispersive infra red (NDIR) monitors and by extractive sampling for later laboratory analysis by electron capture gas chromatography (ECD GC). It was found that the on-line and laboratory methods were in good agreement for samples analyzed within 1-3 h of sampling, but that the nitrous oxide concentration in the stored samples had a tendency to increase with time, which was dependent on the concentration of water in the sample. Experiments with synthetic mixtures showed that the increase in nitrous oxide concentration was consistent with the overall reaction2NO+SO 2→N 2O+SO 3 in which nitric oxide is reduced by sulphur dioxide. The highest average N 2O concentration measured by the on-line analyzer was 16 vpm, and for most of the boilers monitored the concentration was less than 10 vpm. There was no statistically significant difference between the measured N 2O emissions from normal boilers and those fitted with low-NO x burners. It is suggested that these values are close to the true levels of N 2O emissions from p.f. fired boilers and that recent reports of high levels (up to 200 vpm) are likely to be an artefact resulting from the observed generation of N 2O in stored samples. A consequence of these measurements of N 2O is that current estimates of the contribution of emissions from p.f. fired boilers to the global N 2O budget are likely to be too high.
2013-08-01
corrosion can be found on tubes , tubesheets, and in steam- drums, most often near the waterline in steam boilers . Oxygen pitting can also occur anywhere...components present in the feedwater onto wetted boiler surfaces including fire- tubes and water- tubes . Since scale is a good insulator, the thicker...steel surfaces of a steam boiler . However, heavier scale accumulates on the lower steel surfaces of the tubes , mud-drum, and boiler shell. SLUDGE
High Efficiency Liquid-Desiccant Regenerator for Air Conditioning and Industrial Drying
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andrew Lowenstein
2005-12-19
Over 2 quads of fossil fuels are used each year for moisture removal. This includes industrial and agricultural processes where feedstocks and final products must be dried, as well as comfort conditioning of indoor spaces where the control of humidity is essential to maintaining healthy, productive and comfortable working conditions. Desiccants, materials that have a high affinity for water vapor, can greatly reduce energy use for both drying and dehumidification. An opportunity exists to greatly improve the competitiveness of advanced liquid-desiccant systems by increasing the efficiency of their regenerators. It is common practice within the chemical process industry to usemore » multiple stage boilers to improve the efficiency of thermal separation processes. The energy needed to regenerate a liquid desiccant, which is a thermal separation process, can also be reduced by using a multiple stage boiler. In this project, a two-stage regenerator was developed in which the first stage is a boiler and the second stage is a scavenging-air regenerator. The only energy input to this regenerator is the natural gas that fires the boiler. The steam produced in the boiler provides the thermal energy to run the second-stage scavenging-air regenerator. This two-stage regenerator is referred to as a 1?-effect regenerator. A model of the high-temperature stage of a 1?-effect regenerator for liquid desiccants was designed, built and successfully tested. At nominal operating conditions (i.e., 2.35 gpm of 36% lithium chloride solution, 307,000 Btu/h firing rate), the boiler removed 153 lb/h of water from the desiccant at a gas-based efficiency of 52.9 % (which corresponds to a COP of 0.95 when a scavenging-air regenerator is added). The steam leaving the boiler, when condensed, had a solids concentration of less than 10 ppm. This low level of solids in the condensate places an upper bound of about 6 lb per year for desiccant loss from the regenerator. This low loss will not create maintenance problems nor will it significantly increase operating expenses. An energy balance on the boiler showed that heat loss through the insulated jacket was 10%. This value is much higher than the 2% to 5% that is typical of most boilers and indicates a need to better insulate the unit. With insulation that brings jacket losses down to 5%, a 1?-effect regenerator that uses this boiler as its high-temperature stage will have a gas-based COP of 1.05. The estimated cost to manufacture a 300-lb/h, 1?-effect regenerator at 500 units per year is $17,140. Unfortunately, the very high cost for natural gas that now prevails in the U.S. makes it very difficult for a gas-fired LDAC to compete against an electric vapor-compression air conditioner in HVAC applications. However, there are important industrial markets that need very dry air where the high price of natural gas will encourage the sale of a LDAC with the 1?-effect regenerator since in these markets it competes against less efficient gas-fired desiccant technologies. A manufacturer of industrial dehumidification equipment is now negotiating a sales agreement with us that would include the 1?-effect regenerator.« less
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 2 2011-10-01 2011-10-01 false General. 52.25-1 Section 52.25-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-1 General. Requirements for fired boilers of various sizes and uses are referenced in Table 54.01-5(a) of...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false General. 52.25-1 Section 52.25-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-1 General. Requirements for fired boilers of various sizes and uses are referenced in table 54.01-5(a) of...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false General. 52.25-1 Section 52.25-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-1 General. Requirements for fired boilers of various sizes and uses are referenced in Table 54.01-5(a) of...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 2 2013-10-01 2013-10-01 false General. 52.25-1 Section 52.25-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-1 General. Requirements for fired boilers of various sizes and uses are referenced in table 54.01-5(a) of...
FORMATION OF CHLORINATED DIOXINS AND FURANS IN A HAZARDOUS-WASTE-FIRING INDUSTRIAL BOILER
This research examined the potential for emissions of polychlorinated diebnzodioxin and dibenzofuran (PCDD/F) from industrial boilers that cofire hazardous waste. PCDD/F emissions were sampled from a 732 kW (2.5 x 106 Btu/h), 3-pass, firetube boiler using #2 fuel oil cofired wit...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false General. 52.25-1 Section 52.25-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-1 General. Requirements for fired boilers of various sizes and uses are referenced in Table 54.01-5(a) of...
NASA Astrophysics Data System (ADS)
Tugov, A. N.; Ots, A.; Siirde, A.; Sidorkin, V. T.; Ryabov, G. A.
2016-06-01
Prospects of the use of oil shale are associated with its thermal processing for the production of liquid fuel, shale oil. Gaseous by-products, such as low-calorie generator gas with a calorific value up to 4.3MJ/m3 or semicoke gas with a calorific value up to 56.57 MJ/m3, are generated depending on the oil shale processing method. The main methods of energy recovery from these gases are either their cofiring with oil shale in power boilers or firing only under gaseous conditions in reconstructed or specially designed for this fuel boilers. The possible use of gaseous products of oil shale processing in gas-turbine or gas-piston units is also considered. Experiments on the cofiring of oil shale gas and its gaseous processing products have been carried out on boilers BKZ-75-39FSl in Kohtla-Järve and on the boiler TP-101 of the Estonian power plant. The test results have shown that, in the case of cofiring, the concentration of sulfur oxides in exhaust gases does not exceed the level of existing values in the case of oil shale firing. The low-temperature corrosion rate does not change as compared to the firing of only oil shale, and, therefore, operation conditions of boiler back-end surfaces do not worsen. When implementing measures to reduce the generation of NO x , especially of flue gas recirculation, it has been possible to reduce the emissions of nitrogen oxides in the whole boiler. The operation experience of the reconstructed boilers BKZ-75-39FSl after their transfer to the firing of only gaseous products of oil shale processing is summarized. Concentrations of nitrogen and sulfur oxides in the combustion products of semicoke and generator gases are measured. Technical solutions that made it possible to minimize the damage to air heater pipes associated with the low-temperature sulfur corrosion are proposed and implemented. The technological measures for burners of new boilers that made it possible to burn gaseous products of oil shale processing with low emissions of nitrogen oxides are developed.
28. VIEW OF BOILER 901 (IS IT 900?) AT GROUND ...
28. VIEW OF BOILER 901 (IS IT 900?) AT GROUND LEVEL. INSTALLED IN 1928 IT WAS FIRED WITH PULVERIZED COAL. THE PULVERIZERS ARE LOCATED TO THE LEFT AND RIGHT OF THE CENTER ASH PIT ACCESS, BELOW THE CIRCULAR AIR INTAKES. THE PULVERIZED ON THE LEFT WAS POWERED WITH AN ELECTRIC MOTOR WHILE THE UNIT ON THE RIGHT WAS DRIVEN BY A STEAM TURBINE. THE HOPPER (TOP CENTER) WAS FILLED VIA A LARRY CAR WHICH RODE ON TRACKS SUSPENDED ABOVE THE FIRING AISLE. THIS BOILER WAS SHUT DOWN IN 1957. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT
Analysis of thermal radiation in coal-fired furnaces
NASA Astrophysics Data System (ADS)
Miles, Jonathan J.; Hammaker, Robert G.; Madding, Robert P.; Sunderland, J. E.
1997-04-01
Many utilities throughout the United States have added infrared scanning to their arsenal of techniques for inspection and predictive maintenance programs. Commercial infrared scanners are not designed, however, to withstand the searing interiors of boilers, which can exceed 2500 degrees Fahrenheit. Two high-temperature lenses designed to withstand the hostile environment inside a boiler for extended periods of time were developed by the EPRI M&D Center, thus permitting real-time measurement of steam tube temperatures and subsequent analysis of tube condition, inspection of burners, and identification of hot spots. A study was conducted by Sunderland Engineering, Inc. and EPRI M&D in order to characterize the radiative interactions that affect infrared measurements made inside a commercial, coal- fired, water-tube boiler. A comprehensive literature search exploring the existing record of results pertaining to analytical and experimental determination of radiative properties of coal-combustion byproducts was performed. An experimental component intended to provide data for characterization of the optical properties of hot combustion byproducts inside a coal-fired furnace was carried out. The results of the study indicate that hot gases, carbon particles, and fly ash, which together compose the medium inside a boiler, affect to varying degrees the transport of infrared radiation across a furnace. Techniques for improved infrared measurement across a coal-fired furnace are under development.
Environmental impact of emissions from incineration plants in comparison to typical heating systems
NASA Astrophysics Data System (ADS)
Wielgosiński, Grzegorz; Namiecińska, Olga; Czerwińska, Justyna
2018-01-01
In recent years, five modern municipal waste incineration plants have been built in Poland. Next ones are being constructed and at the same time building of several others is being considered. Despite positive experience with the operation of the existing installations, each project of building a new incinerator raises a lot of emotions and social protests. The main argument against construction of an incineration plant is the emission of pollutants. The work compares emissions from municipal waste incineration plants with those from typical heating plants: in the first part, for comparison large heating plants equipped with pulverized coal-fired boilers (OP-140), stoker-fired boilers (three OR-32 boilers) or gas blocks with heat output of about 100 MW have been selected, while the second part compares WR-10 and WR-25 stoker-fired boilers most popular in our heating industry with thermal treatment systems for municipal waste or refuse-derived-fuel (RDF) with similar heat output. Both absolute emission and impact - immission of pollutants in vicinity of the plant were analyzed.
Cost-effectiveness Analysis on Measures to Improve China's Coal-fired Industrial Boiler
Liu, Manzhi; Shen, Bo; Han, Yafeng; ...
2015-08-01
Tackling coal-burning industrial boiler is becoming one of the key programs to solve the environmental problem in China. Assessing the economics of various options to address coal-fired boiler is essential to identify cost-effective solutions. This paper discusses our work in conducting a cost-effectiveness analysis on various types of improvement measures ranging from energy efficiency retrofits to switch from coal to other fuels in China. Sensitivity analysis was also performed in order to understand the impacts of some economic factors such as discount rate and energy price on the economics of boiler improvement options. The results show that nine out ofmore » 14 solutions are cost-effective, and a lower discount rate and higher energy price will result in more energy efficiency measures being cost-effective. Both monetary and non-monetary barriers to energy-efficiency improvement are discussed and policies to tackle these barriers are recommended. Our research aims at providing a methodology to assess cost-effective solutions to boiler problems.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeRosier, R.; Waterland, L.R.
1987-03-01
The report gives emission results from field tests of a wood-waste-fired industrial firetube boiler. Emission measurements included: continuous monitoring of flue gas emissions: source assessment sampling system (SASS) sampling of the flue-gas with subsequent laboratory analysis of samples to give total flue gas organics in two boiling point ranges, compound category information within these ranges, specific quantitation of the semivolatile organic priority pollutants, and flue gas concentrations of 65 trace elements; Method 5 sampling for particulates; controlled condensation system (CSS) sampling for SO/sub 2/ and SO/sub 3/; and grab sampling of boiler bottom ash for trace element content determinations. Totalmore » organic emissions from the boiler were 5.7 mg/dscm, about 90% of which consisted of volatile compounds.« less
NASA Astrophysics Data System (ADS)
Zainudin, A. F.; Hasini, H.; Fadhil, S. S. A.
2017-10-01
This paper presents a CFD analysis of the flow, velocity and temperature distribution in a 700 MW tangentially coal-fired boiler operating in Malaysia. The main objective of the analysis is to gain insights on the occurrences in the boiler so as to understand the inherent steam temperature imbalance problem. The results show that the root cause of the problem comes from the residual swirl in the horizontal pass. The deflection of the residual swirl due to the sudden reduction and expansion of the flow cross-sectional area causes velocity deviation between the left and right side of the boiler. This consequently results in flue gas temperature imbalance which has often caused tube leaks in the superheater/reheater region. Therefore, eliminating the residual swirl or restraining it from being diverted might help to alleviate the problem.
The suitability of ultrafine coal as an industrial boiler fuel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barratt, D.J.; Roberts, P.T.
1989-07-01
Coal that was finely ground to a mean particle size of 12 /mu/m produced a hotter, shorter flame compared to normal pulverized fuel in a pilot scale combustor. Measurements indicated that, should this fuel be fired in an industrial boiler, the rate of ash deposition on the walls and convection tubes could be low, but that the thin ash deposits that were produced might be more highly insulating and would therefore require more frequent cleaning. A mathematical model, using reactivity and pyrolysis data measured in laboratory-scale apparatus, has been used to predict the heat release rate within a boiler. Thismore » would be sufficiently high to allow a premium-quality finely ground coal to be burned in many boilers originally designed for oil firing, provided that burner mixing patterns were optimized.« less
Concept of Heat Recovery from Exhaust Gases
NASA Astrophysics Data System (ADS)
Bukowska, Maria; Nowak, Krzysztof; Proszak-Miąsik, Danuta; Rabczak, Sławomir
2017-10-01
The theme of the article is to determine the possibility of waste heat recovery and use it to prepare hot water. The scope includes a description of the existing sample of coal-fired boiler plant, the analysis of working condition and heat recovery proposals. For this purpose, a series of calculations necessary to identify the energy effect of exhaust temperature decreasing and transferring recovery heat to hot water processing. Heat recover solutions from the exhaust gases channel between boiler and chimney section were proposed. Estimation for the cost-effectiveness of such a solution was made. All calculations and analysis were performed for typical Polish conditions, for coal-fired boiler plant. Typicality of this solution is manifested by the volatility of the load during the year, due to distribution of heat for heating and hot water, determining the load variation during the day. Analysed system of three boilers in case of load variation allows to operational flexibility and adaptation of the boilers load to the current heat demand. This adaptation requires changes in the operating conditions of boilers and in particular assurance of properly conditions for the combustion of fuel. These conditions have an impact on the existing thermal loss and the overall efficiency of the boiler plant. On the boiler plant efficiency affects particularly exhaust gas temperature and the excess air factor. Increasing the efficiency of boilers plant is possible to reach by following actions: limiting the excess air factor in coal combustion process in boilers and using an additional heat exchanger in the exhaust gas channel outside of boilers (economizer) intended to preheat the hot water.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borio, R.W.; Lewis, R.D.; Koucky, R.W.
1996-04-01
Electric utility power plants account for about one-third of the NO{sub x} and two-thirds of the SO{sub 2} emissions in the US cyclone-fired boilers, while representing about 9% of the US coal-fired generating capacity, emit about 14% of the NO{sub x} produced by coal-fired utility boilers. Given this background, the Environmental Protection Agency, the Gas Research Institute, the Electric Power Research Institute, the Pittsburgh Energy Technology Center, and the Ohio Coal Development Office sponsored a program led by ABB Combustion Engineering, Inc. (ABB-CE) to demonstrate reburning on a cyclone-fired boiler. Ohio Edison provided Unit No. 1 at their Niles Stationmore » for the reburn demonstration along with financial assistance. The Niles Unit No. 1 reburn system was started up in September 1990. This reburn program was the first full-scale reburn system demonstration in the US. This report describes work performed during the program. The work included a review of reburn technology, aerodynamic flow model testing of reburn system design concepts, design and construction of the reburn system, parametric performance testing, long-term load dispatch testing, and boiler tube wall thickness monitoring. The report also contains a description of the Niles No. 1 host unit, a discussion of conclusions and recommendations derived from the program, tabulation of data from parametric and long-term tests, and appendices which contain additional tabulated test results.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, P.V.
1995-12-31
Coal fired, low emission sources are a major factor in the air quality problems facing eastern European cities. These sources include: stoker-fired boilers which feed district heating systems and also meet local industrial steam demand, hand-fired boilers which provide heat for one building or a small group of buildings, and masonary tile stoves which heat individual rooms. Global Environmental Systems is marketing through Global Environmental Systems of Polane, Inc. catalysts to improve the combustion of coal, wood or fuel oils in these combustion systems. PCCL-II Combustion Catalysts promotes more complete combustion, reduces or eliminates slag formations, soot, corrosion and somemore » air pollution emissions and is especially effective on high sulfur-high vanadium residual oils. Glo-Klen is a semi-dry powder continuous acting catalyst that is injected directly into the furnace of boilers by operating personnel. It is a multi-purpose catalyst that is a furnace combustion catalyst that saves fuel by increasing combustion efficiency, a cleaner of heat transfer surfaces that saves additional fuel by increasing the absorption of heat, a corrosion-inhibiting catalyst that reduces costly corrosion damage and an air pollution reducing catalyst that reduces air pollution type stack emissions. The reduction of sulfur dioxides from coal or oil-fired boilers of the hand fired stoker design and larger, can be controlled by the induction of the Glo-Klen combustion catalyst and either hydrated lime or pulverized limestone.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-06
... nitrogen (NO X ) emissions from biomass fuel-fired boilers. We are proposing action on a local rule that... Submitted PCAPCD 233 Biomass Boilers......... 12/10/09 05/07/10 On June 8, 2010, the submittal for PCAPCD... from biomass boilers and steam generators. EPA's technical support document (TSD) has more information...
40 CFR 75.53 - Monitoring plan.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Energy and used in the National Allowance Data Base (or equivalent facility ID number assigned by EPA, if...; (C) Type of boiler (or boilers for a group of units using a common stack); (D) Type of fuel(s) fired... more than one fuel, the fuel classification of the boiler; (E) Type(s) of emission controls for SO2...
40 CFR 75.53 - Monitoring plan.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Energy and used in the National Allowance Data Base (or equivalent facility ID number assigned by EPA, if...; (C) Type of boiler (or boilers for a group of units using a common stack); (D) Type of fuel(s) fired... more than one fuel, the fuel classification of the boiler; (E) Type(s) of emission controls for SO2...
40 CFR 63.7491 - Are any boilers or process heaters not subject to this subpart?
Code of Federal Regulations, 2011 CFR
2011-07-01
.../infectious waste incinerator covered by 40 CFR part 60, subpart Ce or subpart Ec. (c) An electric utility... furnace stoves as described in the EPA document, entitled “National Emission Standards for Hazardous Air... boilers as defined in this subpart. (o) Blast furnace gas fuel-fired boilers and process heaters as...
40 CFR 63.1217 - What are the standards for liquid fuel boilers that burn hazardous waste?
Code of Federal Regulations, 2014 CFR
2014-07-01
... boilers that burn hazardous waste? 63.1217 Section 63.1217 Protection of Environment ENVIRONMENTAL... boilers that burn hazardous waste? (a) Emission limits for existing sources. You must not discharge or... provided for in paragraph (a)(2)(iii) of this section: (i) When you burn hazardous waste with an as-fired...
40 CFR 63.1217 - What are the standards for liquid fuel boilers that burn hazardous waste?
Code of Federal Regulations, 2013 CFR
2013-07-01
... boilers that burn hazardous waste? 63.1217 Section 63.1217 Protection of Environment ENVIRONMENTAL... boilers that burn hazardous waste? (a) Emission limits for existing sources. You must not discharge or... provided for in paragraph (a)(2)(iii) of this section: (i) When you burn hazardous waste with an as-fired...
NASA Technical Reports Server (NTRS)
Cukor, P. M.; Chapman, R. A.
1978-01-01
The uncertainties and associated costs involved in selecting and designing a particulate control device to meet California's air emission regulations are considered. The basic operating principles of electrostatic precipitators and fabric filters are discussed, and design parameters are identified. The size and resulting cost of the control device as a function of design parameters is illustrated by a case study for an 800 MW coal-fired fired utility boiler burning a typical southwestern subbituminous coal. The cost of selecting an undersized particulate control device is compared with the cost of selecting an oversized device.
NASA Astrophysics Data System (ADS)
Noor, N. A. W. Mohd; Hassan, H.; Hashim, M. F.; Hasini, H.; Munisamy, K. M.
2017-04-01
This paper presents an investigation on the effects of primary airflow to coal fineness in coal-fired boilers. In coal fired power plant, coal is pulverized in a pulverizer, and it is then transferred to boiler for combustion. Coal need to be ground to its desired size to obtain maximum combustion efficiency. Coarse coal particle size may lead to many performance problems such as formation of clinker. In this study, the effects of primary airflow to coal particles size and coal flow distribution were investigated by using isokinetic coal sampling and computational fluid dynamic (CFD) modelling. Four different primary airflows were tested and the effects to resulting coal fineness were recorded. Results show that the optimum coal fineness distribution is obtained at design primary airflow. Any reduction or increase of air flow rate results in undesirable coal fineness distribution.
Firing of pulverized solvent refined coal
Derbidge, T. Craig; Mulholland, James A.; Foster, Edward P.
1986-01-01
An air-purged burner for the firing of pulverized solvent refined coal is constructed and operated such that the solvent refined coal can be fired without the coking thereof on the burner components. The air-purged burner is designed for the firing of pulverized solvent refined coal in a tangentially fired boiler.
Application of Coal Thermal Treatment Technology for Oil-Free Firing of Boilers
NASA Astrophysics Data System (ADS)
Aliyarov, B.; Mergalimova, A.; Zhalmagambetova, U.
2018-04-01
The theoretical and practical introduction of this kind of firing boiler units in coal thermal power plants is considered in the article. The results of an experimental study of three types of coals are presented in order to obtain the required gaseous fuel. The aim of the study is to develop a new, economically and ecologically more acceptable method for firing boilers at thermal power plants, which is able to exclude the use of expensive and inconvenient fuel oil. The tasks of the experiment are to develop a technological scheme of kindling of boilers at thermal power plants, using as a type of ignition fuel volatile combustible substances released during the heating of coal, and to investigate three types of coal for the suitability of obtaining gaseous fuels, in sufficient volume and with the required heat of combustion. The research methods include the analysis of technical and scientific-methodological literature on the problem of the present study, the study of the experience of scientists of other countries, the full-scale experiment on the production of volatile combustible substances. During the full-scale experiment, the coal of 3 fields of Kazakhstan has been studied: Shubarkul, Maikuben and Saryadyr. The analysis has been performed and the choice of the most convenient technology for boiler kindling and maintenance of steady burning of the torch has been made according to the proposed method, as well as the corresponding technological scheme has been developed. As a result of the experiment, it can be stated that from coal in the process of its heating (without access to oxygen), it is possible to obtain a sufficient amount of combustible volatile substances. The released gaseous fuel has the necessary parameters and is quite capable of replacing an expensive fuel oil. The resulting gaseous fuel is quite convenient to use and environmentally cleaner. The piloting scheme developed as a result of the experiment can be introduced in pulverized-coal thermal power plants, as a result of which they become single-fuel.
34. (Credit JTL) Front (north side) of three water tube ...
34. (Credit JTL) Front (north side) of three water tube boilers built by the Heine Safety Boiler Co. of St. Louis, Missouri in 1917; rebuilt in 1938. Front doors opened on center boiler to show water header and inspection plugs for water tubes. Smaller doors beneath open into firebox; boilers presently equipped for gas firing. Operating pressure approx. 150 psi (saturated steam). - McNeil Street Pumping Station, McNeil Street & Cross Bayou, Shreveport, Caddo Parish, LA
Curbing Air Pollution and Greenhouse Gas Emissions from Industrial Boilers in China
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shen, Bo; Price, Lynn K; Lu, Hongyou
China’s industrial boiler systems consume 700 million tons of coal annually, accounting for 18% of the nation’s total coal consumption. Together these boiler systems are one of the major sources of China’s greenhouse gas (GHG) emissions, producing approximately 1.3 gigatons (Gt) of carbon dioxide (CO 2) annually. These boiler systems are also responsible for 33% and 27% of total soot and sulfur dioxide (SO2) emissions in China, respectively, making a substantial contribution to China’s local environmental degradation. The Chinese government - at both the national and local level - is taking actions to mitigate the significant greenhouse gas (GHG) emissionsmore » and air pollution related to the country’s extensive use of coal-fired industrial boilers. The United States and China are pursuing a collaborative effort under the U.S.-China Climate Change Working Group to conduct a comprehensive assessment of China’s coal-fired industrial boilers and to develop an implementation roadmap that will improve industrial boiler efficiency and maximize fuel-switching opportunities. Two Chinese cities – Ningbo and Xi’an – have been selected for the assessment. These cities represent coastal areas with access to liquefied natural gas (LNG) imports and inland regions with access to interprovincial natural gas pipelines, respectively.« less
Pollution reduction technologies being applied to small coal-fired boiler systems in Poland
DOE Office of Scientific and Technical Information (OSTI.GOV)
Markussen, J.M.; Gyorke, D.F.
1997-12-31
To help in alleviating air pollution problems in Poland, various US environmental technologies are being installed in the city of Krakow to reduce emissions from short-stack coal- and coke-fired boilers. Introduction of low-cost, effective US pollution abatement and energy efficiency technologies is being completed through the US-Polish Krakow Clean Fossil Fuels and Energy Efficiency Program. Seven US firms are currently participating in the program; five projects are well under way and two are in the design phase. The technologies being applied in Krakow include modern district heating equipment and controls, coal preparation techniques, micronized coal combustion, automatic combustion controls, andmore » high-efficiency particulate control equipment. These technologies will be discussed along with pollutant reduction results obtained to date. Applications of these technologies are providing some efficient and economical answers to Krakow`s severe air pollution problems. Certainly, these technologies could be equally effective in many industrial cities throughout the world with similar air pollution concerns.« less
Li, Guoqiang; Niu, Peifeng; Wang, Huaibao; Liu, Yongchao
2014-03-01
This paper presents a novel artificial neural network with a very fast learning speed, all of whose weights and biases are determined by the twice Least Square method, so it is called Least Square Fast Learning Network (LSFLN). In addition, there is another difference from conventional neural networks, which is that the output neurons of LSFLN not only receive the information from the hidden layer neurons, but also receive the external information itself directly from the input neurons. In order to test the validity of LSFLN, it is applied to 6 classical regression applications, and also employed to build the functional relation between the combustion efficiency and operating parameters of a 300WM coal-fired boiler. Experimental results show that, compared with other methods, LSFLN with very less hidden neurons could achieve much better regression precision and generalization ability at a much faster learning speed. Copyright © 2013 Elsevier Ltd. All rights reserved.
High Temperature Corrosion Problem of Boiler Components in presence of Sulfur and Alkali based Fuels
NASA Astrophysics Data System (ADS)
Ghosh, Debashis; Mitra, Swapan Kumar
2011-04-01
Material degradation and ageing is of particular concern for fossil fuel fired power plant components. New techniques/approaches have been explored in recent years for Residual Life assessment of aged components and material degradation due to different damage mechanism like creep, fatigue, corrosion and erosion etc. Apart from the creep, the high temperature corrosion problem in a fossil fuel fired boiler is a matter of great concern if the fuel contains sulfur, chlorine sodium, potassium and vanadium etc. This paper discusses the material degradation due to high temperature corrosion in different critical components of boiler like water wall, superheater and reheater tubes and also remedial measures to avoid the premature failure. This paper also high lights the Residual Life Assessment (RLA) methodology of the components based on high temperature fireside corrosion. of different critical components of boiler.
High Temperature Behavior of Cr3C2-NiCr Coatings in the Actual Coal-Fired Boiler Environment
NASA Astrophysics Data System (ADS)
Bhatia, Rakesh; Sidhu, Hazoor Singh; Sidhu, Buta Singh
2015-03-01
Erosion-corrosion is a serious problem observed in steam-powered electricity generation plants, and industrial waste incinerators. In the present study, four compositions of Cr3C2-(Ni-20Cr) alloy coating powder were deposited by high-velocity oxy-fuel spray technique on T-91 boiler tube steel. The cyclic studies were performed in a coal-fired boiler at 1123 K ± 10 K (850 °C ± 10 °C). X-ray diffraction, scanning electron microscopy/energy dispersive X-ray analysis and elemental mapping analysis techniques were used to analyze the corrosion products. All the coatings deposited on T-91 boiler tube steel imparted hot corrosion resistance. The 65 pctCr3C2 -35 pct (Ni-20Cr)-coated T-91 steel sample performed better than all other coated samples in the given environment.
This volume is a compendium of detailed emission and test data from field tests of a firetube industrial boiler burning a coal/oil/water (COW) mixture. The boiler was tested while burning COW fuel, and COW with soda ash added (COW+SA) to serve as an SO2 sorbent. The test data inc...
Level I Energy and Water Survey, ERDC-CERL, Champaign, IL
2015-05-12
heating will allow for better capacity distribution, optimized boiler fire rates, and the flexibility of moving to possibly more efficient methods in the...by 108 hrs/week. The heat transfer coefficient of the areas served by the FCUs was calculat- ed to estimate the energy savings by operating the HVAC...configuration is not op- timal and should be retrofitted. F&S recommended removing one of the 1968 Cleaver Brooks fire -tube boilers and replacing it with two
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1977-12-01
An NOx control technology assessment study was conducted to examine the effectiveness of low-excess-air firing, staged combustion, flue gas recirculation, and current burner/boiler designs as applied to coal-fired utility boilers. Significant variations in NOx emissions exist with boiler type, firing method, and coal type, but a relative comparison of emissions control performance, cost, and operational considerations is presented for each method. The study emphasized the numerous operational factors that are of major importance to the user in selecting and implementing a combustion modification technique. Staged combustion and low-excess-air operation were identified as the most cost-effective methods for existing units. Closemore » control of local air/fuel ratios and rigorous combustion equipment maintenance are essential to the success of both methods. Flue gas recirculation is relatively ineffective and has the added concern of tube erosion. More research is needed to resolve potential corrosion concerns with low-NOx operating modes. Low-NOx burners in conjunction with a compartmentalized windbox are capable of meeting a 0.6-lb/million Btu emission level on new units. Advanced burner designs are being developed to meet research emission goals of approximately 0.25 lb/MBtu.« less
PAH emissions from old and new types of domestic hot water boilers.
Horak, Jiri; Kubonova, Lenka; Krpec, Kamil; Hopan, Frantisek; Kubesa, Petr; Motyka, Oldrich; Laciok, Vendula; Dej, Milan; Ochodek, Tadeas; Placha, Daniela
2017-06-01
Five different domestic heating boilers (automatic, over-fire, with down-draft combustion and gasification) and three types of fuel (lignite, wood and mixed fuel) were examined in 25 combustion tests and correlated with the emissions of particulate matter (PM), carbon monoxide (CO), total organic carbon (TOC) and 12 polycyclic aromatic hydrocarbons (PAHs with MW = 178-278 g/mol) focusing on particle phase. However, the distribution of 12 PAHs in gas phase was considered as well due to the presence mainly of lighter PAHs in gas phase. The PAHs, as well as the CO and TOC, are the indicators of incomplete combustion, and in this study PAH emission increased significantly with increasing emissions of CO and TOC. The PAHs were mainly detected on PM 2.5 , their contents were increasing linearly with increasing PM 2.5 emissions. The highest emission factors of PAHs were measured for boilers of old construction, such as over-fire boiler (5.8-929 mg/kg) and boiler with down-draft combustion (3.1-54.1 mg/kg). Modern types of boilers produced much lower emissions of PAHs, in particular, automatic boiler (0.3-3.3 mg/kg) and gasification boilers (0.2-6.7 mg/kg). In general, the inefficient combustion at reduced output of boilers generated 1.4-17.7 times more emissions of PAHs than the combustion at nominal output of boilers. It is recommended to operate boilers at nominal output with sufficient air supply and to use the proper fuel to minimise PAHs emissions from domestic heating appliances. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ren, Feng; Li, Zhengqi; Chen, Zhichao; Fan, Subo; Liu, Guangkui
2010-08-15
Down-fired boilers used to burn low-volatile coals have high NO(x) emissions. To find a way of solving this problem, an overfire air (OFA) system was introduced on a 300 MW(e) down-fired boiler. Full-scale experiments were performed on this retrofitted boiler to explore the influence of the OFA ratio (the mass flux ratio of OFA to the total combustion air) on the combustion and NO(x) emission characteristics in the furnace. Measurements were taken of gas temperature distributions along the primary air and coal mixture flows, average gas temperatures along the furnace height, concentrations of gases such as O(2), CO, and NO(x) in the near-wall region and carbon content in the fly ash. Data were compared for five different OFA ratios. The results show that as the OFA ratio increases from 12% to 35%, the NO(x) emission decreases from 1308 to 966 mg/Nm(3) (at 6% O(2) dry) and the carbon content in the fly ash increases from 6.53% to 15.86%. Considering both the environmental and economic effect, 25% was chosen as the optimized OFA ratio.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., petroleum, coal, or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired... enclosed fossil- or other-fuel-fired combustion device used to produce heat and to transfer heat to... means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine: (1...
Code of Federal Regulations, 2011 CFR
2011-07-01
..., petroleum, coal, or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired... enclosed fossil- or other-fuel-fired combustion device used to produce heat and to transfer heat to... means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine: (1...
Code of Federal Regulations, 2013 CFR
2013-07-01
..., petroleum, coal, or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired... enclosed fossil- or other-fuel-fired combustion device used to produce heat and to transfer heat to... means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine: (1...
Code of Federal Regulations, 2014 CFR
2014-07-01
..., petroleum, coal, or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired... enclosed fossil- or other-fuel-fired combustion device used to produce heat and to transfer heat to... means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine: (1...
Code of Federal Regulations, 2012 CFR
2012-07-01
..., petroleum, coal, or any form of solid, liquid, or gaseous fuel derived from such material. Fossil-fuel-fired... enclosed fossil- or other-fuel-fired combustion device used to produce heat and to transfer heat to... means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine: (1...
Technology of forced flow and once-through boiling: A survey. [pressure distribution
NASA Technical Reports Server (NTRS)
Poppendieck, H. F.; Sabin, C. M.
1975-01-01
Representative boiling heat transfer and pressure drop information obtained primarily from past NASA and AEC programs is presented which is applicable to forced flow and once-through boiler systems. The forced convection boiler has a number of advantages: little possibility of flow mal-distribution; heat transfer characteristics are usually consistent; and conductances are predictable, so that higher heat fluxes may be employed with safety (which leads to more compact, lighter weight equipment). It was found that in gas-fired systems particularly, the controlling heat transfer resistance may be on the hot side, so that increased fluxes would require extended surfaces. If in a power generation system the working fluid is very expensive, a forced flow boiler can be designed especially for small holdup volume. If the fluid is temperature sensitive, the boiling side wall temperatures can be tailored to maintain maximum heat transfer rates without overheating the fluid. The forced flow and once-through configurations may be the only type which can satisfy a specific need (such as the automotive Rankine cycle power plant design having a very short time-response boiler).
13. RW Meyer Sugar Mill: 18761889. Engine and boiler house, ...
13. RW Meyer Sugar Mill: 1876-1889. Engine and boiler house, ca. 1881. Locomotive-type, fire-tube, portable boiler, no. I model. Manufactured by Ames Iron Works, Oswego, New York, 1879. 120 lbs./sq. in. working pressure, 66 sq. ft. heating surface in tubes. View: Historical view, 1934, from T.T. Waterman Collection, Hawaiian Sugar Planters' Association. View shows engine and boiler house structure intact. The water and pressure gauge to the right of the boiler are in more complete condition than in 1978 views. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI
Field Test of Boiler Primary Loop Temperature Controller
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glanville, P.; Rowley, P.; Schroeder, D.
Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoring (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. For hydronic boilers specifically, these devices perform load monitoring, with continuous measurement of supply and, in some cases, return water temperatures. Energy savings from these ALM controllers are derived from dynamic management of the boiler differential, where a microprocessor with memory of past boiler cycles prevents the boiler from firing for a period of time, to limit cycling losses and inefficient operation duringmore » perceived low load conditions. These differ from OTR controllers, which vary boiler setpoint temperatures with ambient conditions while maintaining a fixed differential.« less
Boiler burden reduced at Bedford site.
Horsley, Chris
2011-10-01
With the NHS aiming to reduce its 2007 carbon footprint by 10% by 2015, Chris Horsley, managing director of Babcock Wanson UK, a provider of industrial boilers and burners, thermal oxidisers, air treatment, water treatment, and associated services, looks at how one NHS Trust has approached the challenge, and considerably reduced its carbon emissions, by refurbishing its boiler house and moving from oil to gas-fired steam generation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qu, Ming; Abdelaziz, Omar; Yin, Hongxi
2014-11-01
Conventional natural gas-fired boilers exhaust flue gas direct to the atmosphere at 150 200 C, which, at such temperatures, contains large amount of energy and results in relatively low thermal efficiency ranging from 70% to 80%. Although condensing boilers for recovering the heat in the flue gas have been developed over the past 40 years, their present market share is still less than 25%. The major reason for this relatively slow acceptance is the limited improvement in the thermal efficiency of condensing boilers. In the condensing boiler, the temperature of the hot water return at the range of 50 60more » C, which is used to cool the flue gas, is very close to the dew point of the water vapor in the flue gas. Therefore, the latent heat, the majority of the waste heat in the flue gas, which is contained in the water vapor, cannot be recovered. This paper presents a new approach to improve boiler thermal efficiency by integrating absorption heat pumps with natural gas boilers for waste heat recovery (HRAHP). Three configurations of HRAHPs are introduced and discussed. The three configurations are modeled in detail to illustrate the significant thermal efficiency improvement they attain. Further, for conceptual proof and validation, an existing hot water-driven absorption chiller is operated as a heat pump at operating conditions similar to one of the devised configurations. An overall system performance and economic analysis are provided for decision-making and as evidence of the potential benefits. These three configurations of HRAHP provide a pathway to achieving realistic high-efficiency natural gas boilers for applications with process fluid return temperatures higher than or close to the dew point of the water vapor in the flue gas.« less
Novel CFB Boiler Technology with Reconstruction of its Fluidization State
NASA Astrophysics Data System (ADS)
Yang, H. R.; Zhang, H.; Lu, J. F.; Lfu, Q.; Wu, Y. X.; Yuet, G. X.; Su, J.; Fu, Z. P.
Compared with a conventional pulverized coal fired boiler, the combustion efficiency of a CFB boiler is lower while the self-consumed service power is 1-2% higher. The solution of these problems is the key research topic for researchers and manufacturers of CFB boilers. Based on the State Specification Design Theory of CFB boilers, Tsinghua University proposed a novel CFB technology by reconstruction of the fluidization state in the furnace by adjusting the bed inventory and bed quality. Theoretical analyses show that there is an optimal bed pressure drop, around which the boiler operation can achieve the maximal combustion efficiency and with significant reduction of the wear of the heating surface and fan power consumption. The proposed novel process was implemented in a 75t/h CFB boiler. The results of field tests on this boiler validated the theoretical analyses.
NASA Technical Reports Server (NTRS)
1982-01-01
Fire hazard is greater in atmospheres containing a high percentage of oxygen under pressure. NASA intensified its fire safety research after a 1967 Apollo fire. A chemically treated fabric called Durette developed by Monsanto Company, which will not burn or produce noxious fumes, was selected as a material for Apollo astronaut garments. Monsanto sold production rights for this material to Fire Safe Products (FSP). Durette is now used for a wide range of applications such as: sheets, attendants' uniforms in hyperbaric chambers; crew's clothing, furniture and interior walls of diving chambers operated by the U.S. Navy and other oceanographic companies and research organizations. Pyrotect Safety Equipment, Minneapolis, MN produces Durette suits for auto racers, refuelers and crew chiefs from material supplied by FSP. FSP also manufactures Durette bags for filtering gases and dust from boilers, electric generators and similar systems. Durette bags are an alternative to other felted fiber capable of operating at high temperature that cost twice as much.
Characterization of carbonaceous aerosols emitted from outdoor wood boilers
This study examines the chemical properties of carbonaceous aerosols emitted from different outdoor wood-fired boiler (OWB) technologies including two cord-wood heaters, a pellet heater, and a multistage gasifier/combustor. The effect of fuel type [red oak wood (Quercus rubra), w...
A demonstration test and evaluation of the Cannon Low-NO{sub x} Digester System. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-08-01
Since 1985, Cannon Boiler Works, Inc. has been carrying out research and development efforts to perfect a system for removing nitrogen oxides, NO{sub x}, from the exhaust gases of furnaces, gas turbines, chemical reactors, incinerators and boilers.Computer simulations, bench-scale tests and pilot plant testing have proved that the system is capable of removing substantially all of the NO{sub x} from natural gas-fired equipment exhaust streams. Furthermore when retrofit to industrial boilers, both capital costs and operating costs are lower than for competing processes, while performance is much better. The Cannon system for removing NO{sub x}, originally designated as the Cannonmore » NO{sub x} Digester, has recently been renamed the Low Temperature Oxidation (LTO) System for NO{sub x} and SO{sub x} Reduction. It will be engineered and marketed by Cannon Technology, Inc, a wholly owned subsidiary of Cannon Boiler Works, Inc. Cannon has US patents for the process and for the associated equipment and has patent applications pending in Europe. Cannon`s Low Temperature Oxidation, LTO, process has proved effective for reducing the levels of NO{sub x}, CO, CO{sub 2}, SO{sub 2} and particulates from boiler flue gases.« less
Study of Nox Emission Characteristics of a 1025t/h Coal-Fired Circulating Fluidized Bed Boiler
NASA Astrophysics Data System (ADS)
Li, Q. Y.; Mi, Z. D.; Zhang, Q. F.
Measurements of emission are carried out in a 1025t/h CFB boiler. The effect of some factors including coal properties, bed temperature, unit load, excess air on the emission of NOx are investigated. The measurement results show that the N concentration in the coal is dominant parameter to predict the NOx emission from a large-scale CFB boiler. NOx emission from the 1025t/h CFB boiler increases with cyclone temperature and upper pressure drop due to post combustion and external cycle.
The enrichment behavior of natural radionuclides in pulverized oil shale-fired power plants.
Vaasma, Taavi; Kiisk, Madis; Meriste, Tõnis; Tkaczyk, Alan Henry
2014-12-01
The oil shale industry is the largest producer of NORM (Naturally Occurring Radioactive Material) waste in Estonia. Approximately 11-12 million tons of oil shale containing various amounts of natural radionuclides is burned annually in the Narva oil shale-fired power plants, which accounts for approximately 90% of Estonian electricity production. The radionuclide behavior characteristics change during the fuel combustion process, which redistributes the radionuclides between different ash fractions. Out of 24 operational boilers in the power plants, four use circulating fluidized bed (CFB) technology and twenty use pulverized fuel (PF) technology. Over the past decade, the PF boilers have been renovated, with the main objective to increase the efficiency of the filter systems. Between 2009 and 2012, electrostatic precipitators (ESP) in four PF energy blocks were replaced with novel integrated desulphurization technology (NID) for the efficient removal of fly ash and SO2 from flue gases. Using gamma spectrometry, activity concentrations and enrichment factors for the (238)U ((238)U, (226)Ra, (210)Pb) and (232)Th ((232)Th, (228)Ra) family radionuclides as well as (40)K were measured and analyzed in different PF boiler ash fractions. The radionuclide activity concentrations in the ash samples increased from the furnace toward the back end of the flue gas duct. The highest values in different PF boiler ash fractions were in the last field of the ESP and in the NID ash, where radionuclide enrichment factors were up to 4.2 and 3.3, respectively. The acquired and analyzed data on radionuclide activity concentrations in different PF boiler ashes (operating with an ESP and a NID system) compared to CFB boiler ashes provides an indication that changes in the fuel (oil shale) composition and boiler working parameters, as well as technological enhancements in Estonian oil shale fired power plants, have had a combined effect on the distribution patterns of natural radionuclides in the oil shale combustion products. Copyright © 2014 Elsevier Ltd. All rights reserved.
NITROUS OXIDE EMISSIONS FROM FOSSIL FUEL COMBUSTION
The role of coal combustion as a significant global source of nitrous oxide (N2O) emissions was reexamined through on-line emission measurements from six pulverized-coal-fired utility boilers and from laboratory and pilot-scale combustors. The full-scale utility boilers yielded d...
NASA Technical Reports Server (NTRS)
Williams, J. R.
1974-01-01
The conversion of fossil-fired power plants now burning oil or gas to burn coal is discussed along with the relaxation of air quality standards and the development of coal gasification processes to insure a continued supply of gas from coal. The location of oil fields, refining areas, natural gas fields, and pipelines in the U.S. is shown. The technologies of modern fossil-fired boilers and gas turbines are defined along with the new technologies of fluid-bed boilers and MHD generators.
Advanced, Low/Zero Emission Boiler Design and Operation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Babcock /Wilcox; Illinois State Geological; Worley Parsons
2007-06-30
In partnership with the U.S. Department of Energy's National Energy Technology Laboratory, B&W and Air Liquide are developing and optimizing the oxy-combustion process for retrofitting existing boilers as well as new plants. The main objectives of the project is to: (1) demonstrate the feasibility of the oxy-combustion technology with flue gas recycle in a 5-million Btu/hr coal-fired pilot boiler, (2) measure its performances in terms of emissions and boiler efficiency while selecting the right oxygen injection and flue gas recycle strategies, and (3) perform technical and economic feasibility studies for application of the technology in demonstration and commercial scale boilers.more » This document summarizes the work performed during the period of performance of the project (Oct 2002 to June 2007). Detailed technical results are reported in corresponding topical reports that are attached as an appendix to this report. Task 1 (Site Preparation) has been completed in 2003. The experimental pilot-scale O{sub 2}/CO{sub 2} combustion tests of Task 2 (experimental test performance) has been completed in Q2 2004. Process simulation and cost assessment of Task 3 (Techno-Economic Study) has been completed in Q1 2005. The topical report on Task 3 has been finalized and submitted to DOE in Q3 2005. The calculations of Task 4 (Retrofit Recommendation and Preliminary Design of a New Generation Boiler) has been completed in 2004. In Task 6 (engineering study on retrofit applications), the engineering study on 25MW{sub e} unit has been completed in Q2, 2008 along with the corresponding cost assessment. In Task 7 (evaluation of new oxy-fuel power plants concepts), based on the design basis document prepared in 2005, the design and cost estimate of the Air Separation Units, the boiler islands and the CO{sub 2} compression and trains have been completed, for both super and ultra-supercritical case study. Final report of Task-7 is published by DOE in Oct 2007.« less
CHARACTERIZATION OF AIR TOXICS FROM AN OIL-FIRED FIRETUBE BOILER
Tests were conducted on a commercially available firetube package boiler running on #2 through #6 oils to determine the emissions levels of hazardous air pollutants (HAPs) from the combustion of four fuel oils. Flue gas was sampled to determine levels of volatile and semivolatile...
Watkins, Emily R; Richardson, Alan J
2017-01-01
Fire Service Instructors frequently experience high levels of physiological and perceptual strain during live fire exposures. Instructors are also at risk of cardiovascular illnesses, with cardiac death being the greatest cause of fire fighter death. Current practice for UK instructors is to select undergarment type based on personal preference, between a boiler suit (BOILER) and a wicking base layer (WBL). Research suggests that shorts and t-shirt (SHORTS) may also be a beneficial alternative undergarment choice. The UK South East Fire Service requested an investigation to identify if undergarment selection can lessen the strain experienced by instructors, and reduce the acute inflammatory response to fire exposures. Eight males completed three 45min sessions in a heat chamber (49.5±1.4°C and 16.9±4.3% RH) whilst performing intermittent walking. At the end of heat exposure change in heart rate was not effected by garment type (p=0.061, ηp 2 =0.373). Change in rectal temperature was different between garments (p=0.009, η p 2 =0.271), with trends suggesting that BOILER resulted in a greater change (1.03±0.60°C) than SHORTS (0.76±0.37°C, p=0.589, d=0.21) and WBL (0.72±0.33°C, p=0.545, d=0.25). Interleukin-6 post exposure was greater for BOILER (6.96±0.28pgmL -1 ) than both SHORTS (6.59±0.30pgmL -1 , p=0.043, d=0.42) and WBL (6.45±0.43pgmL -1 , p=0.031, d=0.51). Overall, undergarment type had little impact on physiological or perceptual strain. However, wearing WBL or SHORTS may reduce the inflammatory response, and consequently decrease the risk of cardiovascular events. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-07-01
This Public Design Report presents the design criteria of a DOE Innovative Clean Coal Technology (ICCT) project demonstrating advanced wall-fired combustion techniques for the reduction of NO{sub x} emissions from coal-fired boilers. The project is being conducted at Georgia Power Company`s Plant Hammond Unit 4 (500 MW) near Rome, Georgia. The technologies being demonstrated at this site include Foster Wheeler Energy Corporation`s advanced overfire air system and Controlled Flow/Split Flame low NO{sub x} burner. This report provides documentation on the design criteria used in the performance of this project as it pertains to the scope involved with the low NO{submore » x} burners, advanced overfire systems, and digital control system.« less
Code of Federal Regulations, 2014 CFR
2014-07-01
... fossil- or other-fuel-fired combustion device used to produce heat and to transfer heat to recirculating... the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming-cycle unit: (1...
Code of Federal Regulations, 2012 CFR
2012-07-01
... fossil- or other-fuel-fired combustion device used to produce heat and to transfer heat to recirculating... the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming-cycle unit: (1...
Code of Federal Regulations, 2013 CFR
2013-07-01
... fossil- or other-fuel-fired combustion device used to produce heat and to transfer heat to recirculating... the sequential use of energy. Cogeneration unit means a stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine that is a topping-cycle unit or a bottoming-cycle unit: (1...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hart, D.; Lewis, R.; Tobiasz, R.
1998-07-01
The composition and properties of ash formed during coal firing have a major impact on boiler performance. Higher ash content in the coal can mean higher costs associated with coal handling, transportation, ash removal and ash disposal along with higher costs due to the increased ash content's deleterious effects on pulverizing, combustion and heat transfer. ABB C-E Services, Inc. has conducted research what might be done to minimize the adverse effects of ash on boiler performance for many years. Recently, ABB C-E Services has studied the effects of firing system modifications on ash composition and properties and the effect thesemore » firing system modifications have on overall furnace performance. The subject of this paper is the impact of the installation of the CFS{trademark} yaw angles were varied and particle samples were collected at the waterwalls for the different yaw angles tested. These ash samples were analyzed for ash composition. The results showed that with a larger CFS{trademark} yaw angle (the air stream directed more towards the boiler walls) the base/acid ratio, iron content and sulfur content of the particle samples collected at the waterwall were reduced. This effect is due to several contributing factors: (1) an oxidizing environment produced by injecting more air toward the walls; and (2) an aerodynamic change which impacts the particle combustion time/temperature history.« less
ACCOMPLISHMENTS OF THE AMERICAN-POLISH PROGRAM FOR ELIMINATION OF LOW EMISSIONS IN KRAKOW
DOE Office of Scientific and Technical Information (OSTI.GOV)
BUTCHER,T.A.; PIERCE,B.
1998-11-05
In 1991, US and Polish officials signed a Memorandum of Understanding formally initiating and directing the Cracow Clean Fossil Fuels and Energy Efficiency Program. Developing a program approach for the most effective use of the available funds required considerable effort on the part of all project participants. The team recognized early that the cost of solving the low emissions problem even in only one city far exceeded the amount of available US funds. Economic conditions in Poland limited availability of local capital funds for environmental projects. Imposing environmental costs on struggling companies or city residents under difficult conditions of themore » early 1990's required careful consideration of the economic and political impacts. For all of these reasons the program sought to identify technologies for achieving air quality goals which, through improved efficiency and/or reduced fuel cost, could be so attractive economically as to lead to self-sustaining activities beyond the end of the formal project. The effort under this program has been focused into 5 main areas of interest as follows: (1) Energy Conservation and Extension of Central Station District Heating; (2) Replacement of Coal- and Coke-Fired Boilers with Natural Gas-Fired Boilers; (3) Replacement of Coal-Fired Home Stoves with Electric Heating Appliances; (4) Reduction of Emissions from Stoker-Fired Boiler Houses; and (5) Reduction of Emissions from Coal-Fired Home Heating Stoves.« less
The paper discusses preliminary performance and cost estimates of mercury emission control options for electric utility boilers. Under the Clean Air Act Amendments of 1990, EPA had to determine whether mercury emissions from coal-fired power plants should be regulated. To a...
A bottom-up method to develop pollution abatement cost curves for coal-fired utility boilers
This paper illustrates a new method to create supply curves for pollution abatement using boiler-level data that explicitly accounts for technology costs and performance. The Coal Utility Environmental Cost (CUECost) model is used to estimate retrofit costs for five different NO...
Converting small industrial boilers to burn wood fuels
Raymond L. Sarles; J. Penn Rutherfoord
1982-01-01
Investigates the engineering and economic feasibility of retrofitting two small industrial boilers (32 hp and 52 hp, respectively) for firing green wood fuels. Subjects covered include fuel requirements and costs; availability, storage, and handling of wood fuels; and designs, specifications, stack emissions, cost estimates, and economic feasibility. The economics of...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Szewczyk, T.; Mazur, J.
1995-12-31
Polish graded coal is being burned on existing stoker boilers at MPEC`s Balicka plant, using Control Techtronics microprocess-based system. Pictures were shown of the equipment controlling three hot water WR-10 boilers, and (two) steam 22.5 boilers. The results of this installation include; 85% reduction in stack particulate emission, 25% increase in boiler energy efficiency, 65% reduction in fan electrical energy, achieving {open_quotes}ultra low fire{close_quotes} which provides 3 or 4 to 1 turndown, versus 2 to 1, for substantially reduced fuel use at low heating requirements, and 2 to 3 years payback on invested capital.
Low NO{sub x} burner modifications to front-fired pulverized coal boilers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Broderick, R.G.; Wagner, M.
1998-07-01
Madison Gas and Electric Blount Street Station Units 8 and 9 are Babcock and Wilcox pulverized coal fired and natural gas fired boilers. These boilers were build in the late 1950's and early 1960's with each boiler rated at 425,000 lb./hr of steam producing 50 MW of electricity. The boilers are rated at 9,500 F at 1,350 psig. Each unit is equipped with one Ljungstroem air heater and two B and W EL pulverizers. These units burn subbituminous coal with higher heating value of 10,950 Btu/LB on an as-received basis. The nitrogen content is approximately 1.23% with 15% moisture. Inmore » order to comply with the new Clean Air Act Madison Gas and Electric needs to reduce NO{sub x} on these units to less than .5 LB/mmBtu. Baseline NO{sub x} emissions on these units range between .8--.9 lb./mmBtu. LOIs average approximately 8%. Madison Gas and Electric contracted with RJM Corporation to modify the existing burners to achieve this objective. These modifications consisted of adding patented circumferentially and radially staged flame stabilizers, modifying the coal pipe, and replacing the coal impeller with a circumferentially staged coal spreader. RJM Corporation utilized computational fluid dynamics modeling in order to design the equipment to modify these burners. The equipment was installed during the March 1997 outage and start-up and optimization was conducted in April 1997. Final performance results and economic data will be included in the final paper.« less
Adsorbents for capturing mercury in coal-fired boiler flue gas.
Yang, Hongqun; Xu, Zhenghe; Fan, Maohong; Bland, Alan E; Judkins, Roddie R
2007-07-19
This paper reviews recent advances in the research and development of sorbents used to capture mercury from coal-fired utility boiler flue gas. Mercury emissions are the source of serious health concerns. Worldwide mercury emissions from human activities are estimated to be 1000 to 6000 t/annum. Mercury emissions from coal-fired power plants are believed to be the largest source of anthropogenic mercury emissions. Mercury emissions from coal-fired utility boilers vary in total amount and speciation, depending on coal types, boiler operating conditions, and configurations of air pollution control devices (APCDs). The APCDs, such as fabric filter (FF) bag house, electrostatic precipitator (ESP), and wet flue gas desulfurization (FGD), can remove some particulate-bound and oxidized forms of mercury. Elemental mercury often escapes from these devices. Activated carbon injection upstream of a particulate control device has been shown to have the best potential to remove both elemental and oxidized mercury from the flue gas. For this paper, NORIT FGD activated carbon was extensively studied for its mercury adsorption behavior. Results from bench-, pilot- and field-scale studies, mercury adsorption by coal chars, and a case of lignite-burned mercury control were reviewed. Studies of brominated carbon, sulfur-impregnated carbon and chloride-impregnated carbon were also reviewed. Carbon substitutes, such as calcium sorbents, petroleum coke, zeolites and fly ash were analyzed for their mercury-adsorption performance. At this time, brominated activated carbon appears to be the best-performing mercury sorbent. A non-injection regenerable sorbent technology is briefly introduced herein, and the issue of mercury leachability is briefly covered. Future research directions are suggested.
Economic Analysis of Coal-Fired Cogeneration Plants for Air Force Bases
1990-10-01
control . However, the existing stoker boilers at Griffiss AFB use lime scrubbers for flue gas desulfurization . The following input parameters were used to...boiler plant was newly installed in 1985 and is in excellent condition. Spray dryer scrubbers are used for flue gas desulfurization . 32 5.3.2 Heating Fuel...for stoker boilers in the previous heating plant studies, 1 ,3 and for sites that require flue gas desulfurization , an efficiency of 80% was used
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
This report describes results of a technical, financial and environmental assessment study for a project, which would have included a new TCS micronized coal-fired heating plant for the Produkcja I Hodowla Roslin Ogrodniczych (PHRO) Greenhouse Complex; Krzeszowice, Poland. Project site is about 20 miles west of Krakow, Poland. During the project study period, PHRO utilized 14 heavy oil-fired boilers to produce heat for its greenhouse facilities and also home heating to several adjacent apartment housing complexes. The boilers burn a high-sulfur content heavy crude oil, called mazute, The project study was conducted during a period extended from March 1996 throughmore » February 1997. For size orientation, the PHRO Greenhouse complex grows a variety of vegetables and flowers for the Southern Poland marketplace. The greenhouse area under glass is very large and equivalent to approximately 50 football fields, The new micronized coal fired boiler would have: (1) provided a significant portion of the heat for PHRO and a portion of the adjacent apartment housing complexes, (2) dramatically reduced sulfur dioxide air pollution emissions, while satisfying new Polish air regulations, and (3) provided attractive savings to PHRO, based on the quantity of displaced oil.« less
Emissions of sulfur trioxide from coal-fired power plants.
Srivastava, R K; Miller, C A; Erickson, C; Jambhekar, R
2004-06-01
Emissions of sulfur trioxide (SO3) are a key component of plume opacity and acid deposition. Consequently, these emissions need to be low enough to not cause opacity violations and acid deposition. Generally, a small fraction of sulfur (S) in coal is converted to SO3 in coal-fired combustion devices such as electric utility boilers. The emissions of SO3 from such a boiler depend on coal S content, combustion conditions, flue gas characteristics, and air pollution devices being used. It is well known that the catalyst used in the selective catalytic reduction (SCR) technology for nitrogen oxides control oxidizes a small fraction of sulfur dioxide in the flue gas to SO3. The extent of this oxidation depends on the catalyst formulation and SCR operating conditions. Gas-phase SO3 and sulfuric acid, on being quenched in plant equipment (e.g., air preheater and wet scrubber), result in fine acidic mist, which can cause increased plume opacity and undesirable emissions. Recently, such effects have been observed at plants firing high-S coal and equipped with SCR systems and wet scrubbers. This paper investigates the factors that affect acidic mist production in coal-fired electric utility boilers and discusses approaches for mitigating emission of this mist.
Life Cycle Assessment of Coal-fired Power Production
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spath, P. L.; Mann, M. K.; Kerr, D. R.
1999-09-01
Coal has the largest share of utility power generation in the US, accounting for approximately 56% of all utility-produced electricity (US DOE, 1998). Therefore, understanding the environmental implications of producing electricity from coal is an important component of any plan to reduce total emissions and resource consumption. A life cycle assessment (LCA) on the production of electricity from coal was performed in order to examine the environmental aspects of current and future pulverized coal boiler systems. Three systems were examined: (1) a plant that represents the average emissions and efficiency of currently operating coal-fired power plants in the US (thismore » tells us about the status quo), (2) a new coal-fired power plant that meets the New Source Performance Standards (NSPS), and (3) a highly advanced coal-fired power plant utilizing a low emission boiler system (LEBS).« less
NASA Astrophysics Data System (ADS)
Okubo, M.; Fujishima, H.; Yamato, Y.; Kuroki, T.; Tanaka, A.; Otsuka, K.
2013-03-01
A pilot-scale low-emission boiler system consisting of a bio-fuel boiler and plasma-chemical hybrid NOx removal system is investigated. This system can achieve carbon neutrality because the bio-fuel boiler uses waste vegetable oil as one of the fuels. The plasma-chemical hybrid NOx removal system has two processes: NO oxidation by ozone produced from plasma ozonizers and NO2 removal using a Na2SO3 chemical scrubber. Test demonstrations of the system are carried out for mixed oils (mixture of A-heavy oil and waste vegetable oil). Stable combustion is achieved for the mixed oil (20 - 50% waste vegetable oil). Properties of flue gas—e.g., O2, CO2 and NOx—when firing mixed oils are nearly the same as those when firing heavy oil for an average flue gas flow rate of 1000 Nm3/h. NOx concentrations at the boiler outlet are 90 - 95 ppm. Furthermore, during a 300-min continuous operation when firing 20% mixed oil, NOx removal efficiency of more than 90% (less than 10 ppm NOx emission) is confirmed. In addition, the CO2 reduction when heavy oil is replaced with waste vegetable oil is estimated. The system comparison is described between the plasma-chemical hybrid NOx removal and the conventional technology.
Co-firing of paper mill sludge and coal in an industrial circulating fluidized bed boiler.
Tsai, Meng-Yuan; Wu, Keng-Tung; Huang, Chin-Cheng; Lee, Hom-Ti
2002-01-01
Co-firing of coal and paper mill sludge was conducted in a 103 MWth circulating fluidized bed boiler to investigate the effect of the sludge feeding rate on emissions of SOx, NOx, and CO. The preliminary results show that emissions of SOx and Nx decrease with increasing sludge feeding rate, but CO shows the reverse tendency due to the decrease in combustion temperature caused by a large amount of moisture in the sludge. All emissions met the local environmental requirements. The combustion ashes could be recycled as feed materials in the cement manufacturing process.
Particulate Air Pollution Control for Army Coal-Fired Boiler Plants.
1983-03-01
Army flue gas . The condensed material usually is sticky and emissions control . Of the current new technologies. traps the flyash on the bag, where it... control device is made a matter of convenience. The location Flue gas temperature control is an important factor of other components is given the prime...consideration. *in the application of baghouses to flue gas particulate This often results in the particle-laden gas being forced control . Bag
40 CFR 52.21 - Prevention of significant deterioration of air quality.
Code of Federal Regulations, 2010 CFR
2010-07-01
... potential to emit, 100 tons per year or more of any regulated NSR pollutant: Fossil fuel-fired steam... NAICS codes 325193 or 312140), fossil-fuel boilers (or combinations thereof) totaling more than 250... included in NAICS codes 325193 or 312140; (u) Fossil-fuel boilers (or combination thereof) totaling more...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-20
... and oil-fired furnaces and boilers consume both fossil fuel and electricity. Electric furnaces and boilers only consume electricity. In this test procedure, fossil-fuel energy consumption is accounted for comprehensively over a full-year cycle, thereby satisfying EISA 2007 requirements for fossil-fuel standby mode and...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-05
... different in mathematical form, is conceptually the same as the integrated AFUE for fossil fueled furnaces... that gas-fired and oil-fried furnaces and boilers consume both fossil fuel and electricity, while electric furnaces and boilers only consume electricity. The current test procedure accounts for all fossil...
This volume describes emission results from sampling of flue gas from a firetube boiler burning a coal/oil/water (COW) mixture and COW with soda ash added (COW+SA) to control SO2 emissions. Measurements included: continuous monitoring of flue gas emissions; source assessment samp...
THREE STAGE COMBUSTION (REBURNING) TEST RESULTS FROM A 300 MW BOILER IN THE UKRAINE
The paper gives results of a program to design, install, and test a natural gas three-stage combustion (reburn) system on a 300-MWe, opposed-wall, wetbottom (slagging) coal-fired utility boiler operating in the Ukraine. The U. S. EPA sponsored this-program in support of a working...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olthoff, Edward
The Municipal Electric Utility of the City of Cedar Falls (dba Cedar Fals Utilities or CFU) received a congressionally directed grant funded through DOE-EERE to run three short (4 hour) duration test burns and one long (10 days) duration test burn to test the viability of renewable fuels in Streeter Station Boiler #6, a stoker coal fired electric generation unit. The long test burn was intended to test supply chain assumptions, optimize boiler combustion and assess the effects of a longer duration burn of biomass on the boiler.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-11-03
Holston Army Ammunition Plant (HSAAP) in Holston, Tennessee, manufactures explosives from raw materials. The facility comprises two separate areas designated Area `A11 and Area 11B`. Each area is served by a steam plant which produces steam for production processes, equipment operation, space heating, domestic water heating, steam tracing, and product storage heating requirements. The purpose of this study is to identify and evaluate the technical and economic feasibility of alternative methods of meeting the steam requirements of the Area 11A11 industrial complex. The following items were specifically requested to be evaluated. Evaluate the use of two new gas-fired packaged boilersmore » sized to meet the requirements of the industrial complex. The new boilers would be installed adjacent to the existing steam plant and would utilize the existing smokestacks and steam distribution system. Evaluate using the existing steam distribution system rather than locating multiple boilers at various sites. Existing steam driven chillers will be replaced with electric driven equipment. Evaluate this impact on the steam system requirements. Field survey and test two existing gas-fired packaged boilers located at the Volunteer Army Ammunition Plant in Chattanooga, Tennessee. The two boilers were last used about 1980 and are presently laid away. The boilers are approximately the same capacity and operating characteristics as the ones at HSAAP. Relocation of the existing boilers and ancillary equipment (feedwater pumps, generators, fans, etc.) would be required as well as repairs or modifications necessary to meet current operating conditions and standards.« less
Thermal Spray Coatings for High-Temperature Corrosion Protection in Biomass Co-Fired Boilers
NASA Astrophysics Data System (ADS)
Oksa, M.; Metsäjoki, J.; Kärki, J.
2015-01-01
There are over 1000 biomass boilers and about 500 plants using waste as fuel in Europe, and the numbers are increasing. Many of them encounter serious problems with high-temperature corrosion due to detrimental elements such as chlorides, alkali metals, and heavy metals. By HVOF spraying, it is possible to produce very dense and well-adhered coatings, which can be applied for corrosion protection of heat exchanger surfaces in biomass and waste-to-energy power plant boilers. Four HVOF coatings and one arc sprayed coating were exposed to actual biomass co-fired boiler conditions in superheater area with a probe measurement installation for 5900 h at 550 and 750 °C. The coating materials were Ni-Cr, IN625, Fe-Cr-W-Nb-Mo, and Ni-Cr-Ti. CJS and DJ Hybrid spray guns were used for HVOF spraying to compare the corrosion resistance of Ni-Cr coating structures. Reference materials were ferritic steel T92 and nickel super alloy A263. The circulating fluidized bed boiler burnt a mixture of wood, peat and coal. The coatings showed excellent corrosion resistance at 550 °C compared to the ferritic steel. At higher temperature, NiCr sprayed with CJS had the best corrosion resistance. IN625 was consumed almost completely during the exposure at 750 °C.
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeRosier, R.; Waterland, L.R.
1987-03-01
The report gives emission results from field tests of a wood-waste-fired industrial firetube boiler. Emission measurements included: continuous monitoring of flue-gas emissions; source assessment sampling system (SASS) sampling of the flue gas with subsequent laboratory analysis of samples to give total flue-gas organics in two boiling-point ranges, compound category information within these ranges, specific quantitation of the semivolatile organic priority pollutants, and flue-gas concentrations of 65 trace elements; Method 5 sampling for particulates; controlled condensation system (CSS) sampling for SO/sub 2/ and SO/sub 3/; and grab sampling of boiler bottom ash for trace-element-content determinations. Emission levels of five polycyclic organicmore » matter species and phenol were quantitated: except for naphthalene, all were emitted at less than 0.4 microgram/dscm.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mutanen, K.I.
Development of fluidized bed combustion (FBC) was started both in North America and in Europe in the 1960`s. In Europe and especially in Scandinavia the major driving force behind the development was the need to find new more efficient technologies for utilization of low-grade fuels like different biomasses and wastes. Both bubbling fluidized bed (BFB) and circulating fluidized bed (CFB) technologies were under intensive R&D,D efforts and have now advanced to dominating role in industrial and district heating power plant markets in Europe. New advanced CFB designs are now entering the markets. In North America and especially in the USmore » the driving force behind the FBC development was initially the need to utilize different types of coals in a more efficient and environmentally acceptable way. The present and future markets seem to be mainly in biomass and multifuel applications where there is benefit from high combustion efficiency, high fuel flexibility and low emissions such as in the pulp and paper industry. The choice between CFB technology and BFB technology is based on selected fuels, emission requirements, plant size and on technical and economic feasibility. Based on Scandinavian experience there is vast potential in the North American industry to retrofit existing oil fired, pulverized coal fired, chemical recovery or grate fired boilers with FBC systems or to build a new FBC based boiler plant. This paper will present the status of CFB technologies and will compare technical and economic feasibility of CFB technology to CFB technology to BFB and also to other combustion methods. Power plant projects that are using advanced CFB technology e.g. Ahlstrom Pyroflow Compact technology for biomass firing and co-firing of biomass with other fuels will also be introduced.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-10-01
The objective of this project is to demonstrate and evaluate commercially available Selective Catalytic Reduction (SCR) catalysts from U.S., Japanese and European catalyst suppliers on a high-sulfur U.S. coal-fired boiler. SCR is a post-combustion nitrogen oxide (NO.) control technology that involves injecting ammonia into the flue gas generated from coal combustion in an electric utility boiler. The flue gas containing ammonia is then passed through a reactor that contains a specialized catalyst. In the presence of the catalyst, the ammonia reacts with NO. to convert it to nitrogen and water vapor. Although SCR is widely practiced in Japan and Europemore » on gas-, oil-, and low-sulfur coal- fired boilers, there are several technical uncertainties associated with applying SCR to U.S. coals. These uncertainties include: 1) potential catalyst deactivation due to poisoning by trace metal species present in U.S. coals that are not present in other fuels. 2) performance of the technology and effects on the balance-of- plant equipment in the presence of high amounts of SO{sub 2} and SO{sub 3}. 3) performance of a wide variety of SCR catalyst compositions, geometries and methods of manufacturer under typical high-sulfur coal-fired utility operating conditions. These uncertainties were explored by operating nine small-scale SCR reactors and simultaneously exposing different SCR catalysts to flue gas derived from the combustion of high sulfur U.S. coal. In addition, the test facility operating experience provided a basis for an economic study investigating the implementation of SCR technology.« less
A demonstration of pig lard as an industrial boiler fuel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, B.G.; Badger, M.; Larsen, J.
Hatfield Quality Meats is a family owned regional meat processor and vendor and has multiple facilities in Pennsylvania. The main plant and corporate offices are located in Hatfield, Pennsylvania where they process 7,000 hogs per day. Two of Hatfield's by-products are lard and choice white grease (CWG), both of which are produced in large quantities. The lard, which is stored warm and liquid, is sold by tanker truck to veal producers, by 55-gallon drums to commercial bakeries, in 5-gallon pails to a variety of restaurants, and periodically in 1-pound tins to grocery stores. The CWG, which is a rendered product,more » is also sold to veal producers. A decrease in sales could leave the company with large excess of these products and difficult disposal problems. Hatfield Quality Meats, Lehigh University, and Penn State's the Energy Institute evaluated the liquid lard as an industrial boiler fuel and obtained the necessary handleability and combustion data to allow for its use as a supplemental fuel in Hatfield's process, were burned in Penn State's research boiler. The boiler, which has a nominal firing rate of two million Btu/h, is a 150 psig working pressure, A-frame watertube boiler. In addition to the lard samples, No.6 fuel oil was fired for baseline comparison. This paper discusses the comparison of lard and No.6 fuel oil as boiler fuels. Issues discussed include fuel characterization, material handling, combustion performance, flame character and stability, and emissions.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-07
... characters, avoid any form of encryption, and be free of any defects or viruses. For additional information... any stationary, fossil-fuel-fired boiler or stationary, fossil-fuel-fired combustion turbine located... included any fossil-fuel-fired unit serving a generator greater than 25 MWe producing electricity for sale...
40 CFR 63.1217 - What are the standards for liquid fuel boilers that burn hazardous waste?
Code of Federal Regulations, 2012 CFR
2012-07-01
... boilers that burn hazardous waste? 63.1217 Section 63.1217 Protection of Environment ENVIRONMENTAL... that burn hazardous waste? (a) Emission limits for existing sources. You must not discharge or cause... paragraph (a)(2)(iii) of this section: (i) When you burn hazardous waste with an as-fired heating value less...
The U.S. EPA operates the Environmental and Sustainable Technology Evaluation (ESTE) program to facilitate the deployment of innovative technologies through performance verification and information dissemination. This ESTE project involved evaluation of co-firing common woody bio...
Process to improve boiler operation by supplemental firing with thermally beneficiated low rank coal
Sheldon, Ray W.
2001-01-01
The invention described is a process for improving the performance of a commercial coal or lignite fired boiler system by supplementing its normal coal supply with a controlled quantity of thermally beneficiated low rank coal, (TBLRC). This supplemental TBLRC can be delivered either to the solid fuel mill (pulverizer) or directly to the coal burner feed pipe. Specific benefits are supplied based on knowledge of equipment types that may be employed on a commercial scale to complete the process. The thermally beneficiated low rank coal can be delivered along with regular coal or intermittently with regular coal as the needs require.
Tuttle, Kenneth L.
1980-01-01
A method of metering underfire air for increasing efficiency and reducing particulate emissions from wood-fire, spreader-stoker boilers is disclosed. A portion of the combustion air, approximately one pound of air per pound of wood, is fed through the grate into the fuel bed, while the remainder of the combustion air is distributed above the fuel in the furnace, and the fuel bed is maintained at a depth sufficient to consume all oxygen admitted under fire and to insure a continuous layer of fresh fuel thereover to entrap charred particles inside the fuel bed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
AQUATECH Systems, a business unit of Allied-Signal Inc., proposes to demonstrate the technical viability and cost effectiveness of the SOXAL process a combined SO{sub x}/NO{sub x} control process on a 3 MW equivalent flue gas slip stream from Niagara Mohawk Power Corporation, Dunkirk Steam Station Boiler No. 4, a coal fired boiler. The SOXAL process combines 90+% sulfur dioxide removal from the flue gas using a sodium based scrubbing solution and regeneration of the spent scrubbing liquor using AQUATECH Systems` proprietary bipolar membrane technology. This regeneration step recovers a stream of sulfur dioxide suitable for subsequent processing to salable sulfurmore » or sulfuric acid. Additionally 90+% control of NO{sub x} gases can be achieved in combination with conventional urea/methanol injection of NO{sub 2} gas into the duct. The SOXAL process is applicable to both utility and industrial scale boilers using either high or low sulfur coal. The SOXAL demonstration Program began September 10, 1991 and is approximately 22 months in duration.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
AQUATECH Systems a business unit of Allied-Signal Inc., proposes to demonstrate the technical viability and cost effectiveness of the SOXAL process a combined SO{sub x}/NO{sub x} control process on a 2--3 MW equivalent flue gas slip stream from Niagara Mohawk Power Corporation, Dunkirk Steam Station Boiler {number_sign}4, a coal fired boiler. The SOXAL process combines 90+% sulfur dioxide removal from the flue gas using a sodium based scrubbing solution and regeneration of the spent scrubbing liquor using AQUATECH Systems` proprietary bipolar membrane technology. This regeneration step recovers a stream of sulfur dioxide suitable for subsequent processing to salable sulfur ormore » sulfuric acid. Additionally 90+% control of NO{sub x} gases can be achieved in combination with conventional urea/methanol injection of NO{sub 2} gas into the duct. The SOXAL process is applicable to both utility and industrial scale boilers using either high or low sulfur coal. The SOXAL Demonstration Program began September 10, 1991 and is approximately 22 months in duration.« less
Assessment of physical workload in boiler operations.
Rodrigues, Valéria Antônia Justino; Braga, Camila Soares; Campos, Julio César Costa; Souza, Amaury Paulo de; Minette, Luciano José; Sensato, Guilherme Luciano; Moraes, Angelo Casali de; Silva, Emília Pio da
2012-01-01
The use of boiler wood-fired is fairly common equipment utilized in steam generation for energy production in small industries. The boiler activities are considered dangerous and heavy, mainly due to risks of explosions and the lack of mechanization of the process. This study assessed the burden of physical labor that operators of boilers are subjected during the workday. Assessment of these conditions was carried out through quantitative and qualitative measurements. A heart rate monitor, a wet-bulb globe thermometer (WBGT), a tape-measure and a digital infrared camera were the instruments used to collect the quantitative data. The Nordic Questionnaire and the Painful Areas Diagram were used to relate the health problems of the boiler operator with activity. With study, was concluded that the boiler activity may cause pains in the body of intensity different, muscle fatigue and diseases due to excessive weight and the exposure to heat. The research contributed to improve the boiler operator's workplace and working conditions.
Report of the Acquisition Cycle Task Force. 1977 Summer Study
1978-03-15
selection and a decision to change from pressure-fired to conventional boilers . These delays extended into the building period and resulted in additional...delays in the program. The acquisition plan was standard for the era. De- lays were caused by decisions made to change the sonar and the boiler design...design changes in the sonar and boiler installation, as well as L C -34 In. V1 CD In - .5 -~j S~ cx cn~~~4 u- L n 1 . WI8 PAG. IS MT QUALtTY PUZCA=LX C-35
1974-02-01
least one of the board members shall be a certified boiler inspector. c. Each board will be a permanently established examining board reporting to the...Initial Light-Off Examination - to be conducted prior to lighting the first fire in any boiler during a regular overhaul, major conversion, or fitting... boiler water and feed water sampling and analysis and casualty control walk-thru drills may be conducted at the discretion of the senior member (or his
The U.S. EPA operates the Environmental and Sustainable Technology Evaluation (ESTE) program to facilitate the deployment of innovative technologies through performance verification and information dissemination. This ESTE project involved evaluation of co-firing common woody bio...
Physical and chemical characterization of residual oil-fired power plant emissions
Although the toxicity of oil combustion emissions is a significant public health concern, few studies characterize the emissions from plant-scale utility boilers firing residual oil. This study remedies that deficiency by sampling and monitoring stack emissions from a 432 Giga Jo...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Season emissions limitation for the source. Fossil fuel means natural gas, petroleum, coal, or any form... right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used... any other fuel, during a specified year. Cogeneration unit means a stationary, fossil-fuel-fired...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Season emissions limitation for the source. Fossil fuel means natural gas, petroleum, coal, or any form... right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used... any other fuel, during a specified year. Cogeneration unit means a stationary, fossil-fuel-fired...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Season emissions limitation for the source. Fossil fuel means natural gas, petroleum, coal, or any form... right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used... any other fuel, during a specified year. Cogeneration unit means a stationary, fossil-fuel-fired...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Season emissions limitation for the source. Fossil fuel means natural gas, petroleum, coal, or any form... right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used... any other fuel, during a specified year. Cogeneration unit means a stationary, fossil-fuel-fired...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Season emissions limitation for the source. Fossil fuel means natural gas, petroleum, coal, or any form... right-of-way tree trimmings. Boiler means an enclosed fossil- or other-fuel-fired combustion device used... any other fuel, during a specified year. Cogeneration unit means a stationary, fossil-fuel-fired...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Butcher, Thomas A.
Direct biomass combustion for the production of heat is a broad field of technology which ranges from residential wood stoves to commercial and industrial boilers and furnaces. Fuels typically include pellets, chips and cord wood. Over the past decade, as a result of fuel price advantages and other benefits, wood burning has seen a significant growth.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-19
... Register on September 6, 2011 and concerns oxides of nitrogen (NO X ) emissions from biomass fuel-fired... SIP. Rule Rule title Amended Submitted PCAPCD 233 Biomass Boilers 12/10/09 05/17/10 We proposed a... emission limits for biomass boilers found in Section 301 implement RACT. Our proposed action contains more...
Šyc, Michal; Horák, Jiří; Hopan, František; Krpec, Kamil; Tomšej, Tomáš; Ocelka, Tomáš; Pekárek, Vladimír
2011-11-01
This study reports on the first complex data set of emission factors (EFs) of selected pollutants from combustion of five fuel types (lignite, bituminous coal, spruce, beech, and maize) in six different domestic heating appliances of various combustion designs. The effect of fuel as well as the effect of boiler type was studied. In total, 46 combustion runs were performed, during which numerous EFs were measured, including the EFs of particulate matter (PM), carbon monoxide, polyaromatic hydrocarbons (PAH), hexachlorobenzene (HxCBz), polychlorinated dibenzo-p-dioxins and furans (PCDD/F), etc. The highest EFs of nonchlorinated pollutants were measured for old-type boilers with over-fire and under-fire designs and with manual stoking and natural draft. Emissions of the above-mentioned pollutants from modern-type boilers (automatic, downdraft) were 10 times lower or more. The decisive factor for emission rate of nonchlorinated pollutants was the type of appliance; the type of fuel plays only a minor role. Emissions of chlorinated pollutants were proportional mainly to the chlorine content in fuel, but the type of appliance also influenced the rate of emissions significantly. Surprisingly, higher EFs of PCDD/F from combustion of chlorinated bituminous coal were observed for modern-type boilers (downdraft, automatic) than for old-type ones. On the other hand, when bituminous coal was burned, higher emissions of HxCBz were found for old-type boilers than for modern-type ones.
Li, Zhengqi; Kuang, Min; Zhang, Jia; Han, Yunfeng; Zhu, Qunyi; Yang, Lianjie; Kong, Weiguang
2010-02-01
Cold airflow experiments were conducted to investigate the aerodynamic field in a small-scale furnace of a down-fired pulverized-coal 300 MW(e) utility boiler arranged with direct flow split burners enriched by cyclones. By increasing the staged-air ratio, a deflected flow field appeared in the lower furnace; larger staged-air ratios produced larger deflections. Industrial-sized experiments on a full-scale boiler were also performed at different staged-air damper openings with measurements taken of gas temperatures in the burner region and near the right-side wall, wall heat fluxes, and gas components (O(2), CO, and NO(x)) in the near-wall region. Combustion was unstable at staged-air damper openings below 30%. For openings of 30% and 40%, late ignition of the pulverized coal developed and large differences arose in gas temperatures and heat fluxes between the regions near the front and rear walls. In conjunction, carbon content in the fly ash was high and boiler efficiency was low with high NO(x) emission above 1200 mg/m(3) (at 6% O(2) dry). For fully open dampers, differences in gas temperatures and heat fluxes, carbon in fly ash and NO(x) emission decreased yielding an increase in boiler efficiency. The optimal setting is fully open staged-air dampers.
NASA Astrophysics Data System (ADS)
Tugov, A. N.; Supranov, V. M.; Izyumov, M. A.; Vereshchetin, V. A.; Usman, Yu. M.; Natal'in, A. S.
2017-12-01
During natural gas combustion, the content of nitrogen oxides in combustion products is approximately 450 mg/m3 in many E-320-13.8-560GM boilers in service, which is more than 3.5 times higher than the established maximum NO x concentrations in flue gases for such boilers. Estimates according to the existing techniques have shown that gas combustion on the basis of in-furnace techniques (the feeding of combustion products to burners together with air in the volume of 15% and two-stage combustion with 20% air feeding through the nozzles upstream of the burners) enables one to decrease NO x emissions to the level of concentrations of less than 100 mg/m3, which is lower than the maximum allowable values. However, the application of any of the proposed measures with respect to a boiler makes its operation under normal load significantly difficult, since the thermal capacity of the superheater is higher in both cases, which leads to an increase in the temperature of superheated steam above the maximum allowable temperature. On the basis of the developed adapted boiler model, which was created using the Boiler Designer software, we performed numerical studies to determine the required boiler reconstruction volume; the implementation of this reconstruction will provide reliable boiler operation at all working loads and ensure the normative values of NO x emissions. According to the results of thermal calculations, it was proposed to reduce the surface of the cold stage of the superheater circuit and increase the size of the economizer. It is noted that the implementation of environmental protection measures usually decreases the boiler efficiency. At the same time, it has been established that the technical and economic performance of the E-320-13.8-560GM boiler does not decrease owing to an increase in the economizer surface and a decrease in air inflows and overflows in regenerative air heaters and remains at the same level if the air inflow volume decreases from the available 30 to 20%. The fundamental solutions that were used for the E-320-13.8-560GM boiler to decrease NO x emissions can also be used for other BKZ gas-and-oil-fired boilers.
Research in Varying Burner Tilt Angle to Reduce Rear Pass Temperature in Coal Fired Boiler
NASA Astrophysics Data System (ADS)
Thrangaraju, Savithry K.; Munisamy, Kannan M.; Baskaran, Saravanan
2017-04-01
This research shows the investigation conducted on one of techniques that is used in Manjung 700 MW tangentially fired coal power plant. The investigation conducted in this research is finding out the right tilt angle for the burners in the boiler that causes an efficient temperature distribution and combustion gas flow pattern in the boiler especially at the rear pass section. The main outcome of the project is to determine the right tilt angle for the burner to create an efficient temperature distribution and combustion gas flow pattern that able to increase the efficiency of the boiler. The investigation is carried out by using Computational Fluid Dynamics method to obtain the results by varying the burner tilt angle. The boiler model is drawn by using designing software which is called Solid Works and Fluent from Computational Fluid Dynamics is used to conduct the analysis on the boiler model. The analysis is to imitate the real combustion process in the real Manjung 700 MW boiler. The expected results are to determine the right burner tilt angle with a computational fluid analysis by obtaining the temperature distribution and combustion gas flow pattern for each of the three angles set for the burner tilt angle in FLUENT software. Three burner tilt angles are selected which are burner tilt angle at (0°) as test case 1, burner tilt angle at (+10°) as test case 2 and burner tilt angle at (-10°) as test case 3. These entire three cases were run in CFD software and the results of temperature distribution and velocity vector were obtained to find out the changes on the three cases at the furnace and rear pass section of the boiler. The results are being compared in analysis part by plotting graphs to determine the right tilting angle that reduces the rear pass temperature.
Code of Federal Regulations, 2013 CFR
2013-07-01
... any form of solid, liquid, or gaseous fuel derived from such material. Fossil fuel-fired means the... average quantity of fossil fuel consumed by a unit, measured in millions of British Thermal Units... high relative to the reference value. Boiler means an enclosed fossil or other fuel-fired combustion...
Code of Federal Regulations, 2011 CFR
2011-07-01
... any form of solid, liquid, or gaseous fuel derived from such material. Fossil fuel-fired means the... average quantity of fossil fuel consumed by a unit, measured in millions of British Thermal Units... high relative to the reference value. Boiler means an enclosed fossil or other fuel-fired combustion...
Code of Federal Regulations, 2012 CFR
2012-07-01
... any form of solid, liquid, or gaseous fuel derived from such material. Fossil fuel-fired means the... average quantity of fossil fuel consumed by a unit, measured in millions of British Thermal Units... high relative to the reference value. Boiler means an enclosed fossil or other fuel-fired combustion...
Code of Federal Regulations, 2013 CFR
2013-07-01
... any form of solid, liquid, or gaseous fuel derived from such material. Fossil fuel fired means, with... subpart H of this part. Boiler means an enclosed fossil or other fuel-fired combustion device used to... efficiency of electricity generation or steam production. Combustion turbine means an enclosed fossil or...
Code of Federal Regulations, 2010 CFR
2010-07-01
... any form of solid, liquid, or gaseous fuel derived from such material. Fossil fuel fired means, with... subpart H of this part. Boiler means an enclosed fossil or other fuel-fired combustion device used to... efficiency of electricity generation or steam production. Combustion turbine means an enclosed fossil or...
Code of Federal Regulations, 2014 CFR
2014-07-01
... any form of solid, liquid, or gaseous fuel derived from such material. Fossil fuel fired means, with... subpart H of this part. Boiler means an enclosed fossil or other fuel-fired combustion device used to... efficiency of electricity generation or steam production. Combustion turbine means an enclosed fossil or...
Code of Federal Regulations, 2011 CFR
2011-07-01
... any form of solid, liquid, or gaseous fuel derived from such material. Fossil fuel fired means, with... subpart H of this part. Boiler means an enclosed fossil or other fuel-fired combustion device used to... efficiency of electricity generation or steam production. Combustion turbine means an enclosed fossil or...
Code of Federal Regulations, 2012 CFR
2012-07-01
... any form of solid, liquid, or gaseous fuel derived from such material. Fossil fuel fired means, with... subpart H of this part. Boiler means an enclosed fossil or other fuel-fired combustion device used to... efficiency of electricity generation or steam production. Combustion turbine means an enclosed fossil or...
Code of Federal Regulations, 2014 CFR
2014-07-01
... any form of solid, liquid, or gaseous fuel derived from such material. Fossil fuel-fired means the... average quantity of fossil fuel consumed by a unit, measured in millions of British Thermal Units... high relative to the reference value. Boiler means an enclosed fossil or other fuel-fired combustion...
UNIVERSITY OF WASHINGTON ELECTROSTATIC SCRUBBER TESTS AT A COAL-FIRED POWER PLANT
The report gives results of tests of a 1700 cu m/hr University of Washington Electrostatic Spray Scrubber pilot plant on a coal-fired boiler to demonstrate its effectiveness for controlling fine particle emissions. The multiple-pass, portable pilot plant combines oppositely charg...
2. RICE THRESHING MILL WITH CHIMNEY STACK. Fire burned on ...
2. RICE THRESHING MILL WITH CHIMNEY STACK. Fire burned on top of water pipe at base of chimney stack and steam went thru pipes to boiler on south side of wall. - Mansfield Plantation, Rice Threshing Mill, U.S. Route 701 vicinity, Georgetown, Georgetown County, SC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giovanni, D.V.; Carr, R.C.; Landham, E.C.
Two products of coal quality research at the Electric Power Research Institute TM (EPRI) are available for field evaluation: Coal Quality Impact Model (CQIM and Fireside Testing Guidelines (FIG). The CQIM is a computer program that may be tailored to simulate the performance characteristics of a coal-fired power plant. The FIG is a technical report that guides utilities in conducting field tests to gather performance data and quantify the technical and economic impacts of different coals. Moreover, the results from field tests may be utilized to validate and assess the applicability of the CQIM. Field tests were conducted at Mississippimore » Power Company`s Watson Unit 4 to evaluate the coal quality impacts of coal switching on boiler performance and emissions. Watson Unit 4 is a 255 MW (gross), opposed-wall, pulverized-coal-fired boiler manufactured by Riley Stoker Corporation and rated at 1,779,000 lb/hr steam flow at 1000{degrees}F superheat steam temperature and 2,500 psig. The unit is equipped with a cold-side electrostatic precipitator for particulate matter control. Comprehensive tests were conducted on all major equipment components, including the pulverizers, fans, combustion equipment, boiler heat transfer surfaces, air preheater, and electrostatic precipitator, for two coals. The CQIN4 was configured to predict the performance of the unit when burning each coal. The work was sponsored by EPRI, and Mississippi Power Company (MPC) was the host utility company. This report summarizes results from the field test program, including potential heat rate improvements that were identified, and the differences in unit operations and performance for the two coals. The results from the CQIM validation effort are also presented.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mok, W.Y.; Cox, W.M.
1992-12-01
The work described in this report was the first British in-plant application of continuous online electrochemical corrosion monitoring technology in pulverized coal-fired superheater environments. The work was conducted at Drax Power Station, National Power plc, UK. The investigation was to evaluate the relative corrosion performance of stainless steel Alloys 316 and 310. Two electrochemical sensor assemblies fabricated from the test alloys were attached to the end of a coupon exposure probe which was inserted into the superheater section of a 660MW boiler. The probe assemblies were exposed at a nominal temperature of 665{degrees}C (1229{degrees}F) during the trial. two series ofmore » short term temperature scanning tests were carried out. Alloy 310 performed comparatively better than Alloy 316. Minimal corrosion loss was sustained by Alloy 310 whilst a characteristic wastage flat was observed on Alloy 316. It was shown that variations in boiler operation could affect the minute-to-minute corrosion behavior of the test materials. The results of the brief temperature scan program indicated a trend of increasing corrosion with exposure temperature. No evidence was observed of the ``bell-shaped`` curve behavior reported in laboratory studies of molten salt corrosion. Metallographic examination of the sensors indicated that only small and discrete areas of internal sulfur enrichment beneath the surface scale. This is untypical of the morphology of sulfur enriched scale found in molten salt corrosion systems. The corrosion processes were predominately in the form of oxidation/sulfidation. The formation of a wastage flat was postulated to have been caused by an electrochemical mechanism similar to that of flow assisted corrosion in aqueous electrolytes. These results confirmed that continuous on-line electrochemical instrumentation could be used to investigate, monitor and characterize high temperature oxidation in power generation boiler superheaters.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mok, W.Y.; Cox, W.M.
1992-12-01
The work described in this report was the first British in-plant application of continuous online electrochemical corrosion monitoring technology in pulverized coal-fired superheater environments. The work was conducted at Drax Power Station, National Power plc, UK. The investigation was to evaluate the relative corrosion performance of stainless steel Alloys 316 and 310. Two electrochemical sensor assemblies fabricated from the test alloys were attached to the end of a coupon exposure probe which was inserted into the superheater section of a 660MW boiler. The probe assemblies were exposed at a nominal temperature of 665[degrees]C (1229[degrees]F) during the trial. two series ofmore » short term temperature scanning tests were carried out. Alloy 310 performed comparatively better than Alloy 316. Minimal corrosion loss was sustained by Alloy 310 whilst a characteristic wastage flat was observed on Alloy 316. It was shown that variations in boiler operation could affect the minute-to-minute corrosion behavior of the test materials. The results of the brief temperature scan program indicated a trend of increasing corrosion with exposure temperature. No evidence was observed of the bell-shaped'' curve behavior reported in laboratory studies of molten salt corrosion. Metallographic examination of the sensors indicated that only small and discrete areas of internal sulfur enrichment beneath the surface scale. This is untypical of the morphology of sulfur enriched scale found in molten salt corrosion systems. The corrosion processes were predominately in the form of oxidation/sulfidation. The formation of a wastage flat was postulated to have been caused by an electrochemical mechanism similar to that of flow assisted corrosion in aqueous electrolytes. These results confirmed that continuous on-line electrochemical instrumentation could be used to investigate, monitor and characterize high temperature oxidation in power generation boiler superheaters.« less
NASA Astrophysics Data System (ADS)
Trinchenko, A. A.; Paramonov, A. P.
2017-10-01
Work is devoted to the solution of problems of energy efficiency increase in low power boilers at combustion of solid fuel. The technological method of nitrogen oxides decomposition on a surface of carbon particles with education environmentally friendly carbonic acid and molecular nitrogen is considered during the work of a low-temperature swirl fire chamber. Based on the analysis of physical and chemical processes of a fuel chemically connected energy transition into thermal, using the diffusive and kinetic theory of burning modern approaches the technique, mathematical model and the settlement program for assessment of plant ecological indicators when using a new method are developed. Alternative calculations of furnace process are carried out, quantitative assessment of nitrogen oxides emissions level of the reconstructed boiler is executed. The results of modeling and experimental data have approved that the organization of swirl burning increases overall performance of a fire chamber and considerably reduces emissions of nitrogen oxides.
Rehabilitation of a 410-MW utility boiler at Costa Sur, Puerto Rico
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosado, R.; Salmeron, M.
1995-12-31
To increase unit reliability and availability and to meet the current and future electric power demands in Puerto Rico, the Puerto Rico Electric Power Authority (PREPA) recently performed a scheduled outage rehabilitation of Costa Sur Power Station Unit 5. This major rehabilitation of a 23-year-old, 410 MW, oil-fired boiler was accompanied by the upgrading of the low-pressure turbine with new rotors. The boiler rehabilitation included the replacement of all waterwall floor panels from just below the burner windbox, down to the lower drum. Temporary support was provided for the lower drum and its structural system during the panel replacement. Themore » steam drum internals were completely rehabilitated, with the installation of a new liner and cleaning and repair of other internals as required. The superheater and reheater desuperheater liners were also replaced. In addition, all major components of both the firing system and the air preheaters were replaced. The gas recirculation fan was rehabilitated, and its discharge duct was replaced.« less
Code of Federal Regulations, 2014 CFR
2014-07-01
... the source: (i) For EGUs and for fossil-fuel-fired non-EGUs that are boilers or combustion turbines... sources in the State. (ii) If a State elects to impose control measures on fossil fuel-fired non-EGUs that... part 75 of this chapter. (ii) If the SIP revision contains measures to control fossil fuel-fired non...
Code of Federal Regulations, 2011 CFR
2011-07-01
... the source: (i) For EGUs and for fossil-fuel-fired non-EGUs that are boilers or combustion turbines... sources in the State. (ii) If a State elects to impose control measures on fossil fuel-fired non-EGUs that... part 75 of this chapter. (ii) If the SIP revision contains measures to control fossil fuel-fired non...
Code of Federal Regulations, 2012 CFR
2012-07-01
... the source: (i) For EGUs and for fossil-fuel-fired non-EGUs that are boilers or combustion turbines... sources in the State. (ii) If a State elects to impose control measures on fossil fuel-fired non-EGUs that... part 75 of this chapter. (ii) If the SIP revision contains measures to control fossil fuel-fired non...
Code of Federal Regulations, 2010 CFR
2010-07-01
... the source: (i) For EGUs and for fossil-fuel-fired non-EGUs that are boilers or combustion turbines... sources in the State. (ii) If a State elects to impose control measures on fossil fuel-fired non-EGUs that... part 75 of this chapter. (ii) If the SIP revision contains measures to control fossil fuel-fired non...
Code of Federal Regulations, 2013 CFR
2013-07-01
... the source: (i) For EGUs and for fossil-fuel-fired non-EGUs that are boilers or combustion turbines... sources in the State. (ii) If a State elects to impose control measures on fossil fuel-fired non-EGUs that... part 75 of this chapter. (ii) If the SIP revision contains measures to control fossil fuel-fired non...
46 CFR 167.45-40 - Fire-fighting equipment on nautical school ships using oil as fuel.
Code of Federal Regulations, 2011 CFR
2011-10-01
... following type and character: (a) In each boiler room and in each of the machinery spaces of a nautical... approved fire extinguishers of the foam type of not less than 9.5 liters (21/2 gallons) each or 2 or more approved fire extinguishers of the carbon dioxide type of not less than 33 kilograms (15 pounds) each must...
46 CFR 167.45-40 - Fire-fighting equipment on nautical school ships using oil as fuel.
Code of Federal Regulations, 2010 CFR
2010-10-01
... following type and character: (a) In each boiler room and in each of the machinery spaces of a nautical... approved fire extinguishers of the foam type of not less than 9.5 liters (21/2 gallons) each or 2 or more approved fire extinguishers of the carbon dioxide type of not less than 33 kilograms (15 pounds) each must...
Ways to Improve Russian Coal-Fired Power Plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tumanovskii, A. G., E-mail: vti@vti.ru; Olkhovsky, G. G.
Coal is an important fuel for the electric power industry of Russia, especially in Ural and the eastern part of the country. It is fired in boilers of large (200 – 800 MW) condensing power units and in many cogeneration power plants with units rated at 50 – 180 MW. Many coal-fired power plants have been operated for more than 40 – 50 years. Though serviceable, their equipment is obsolete and does not comply with the current efficiency, environmental, staffing, and availability standards. It is urgent to retrofit and upgrade such power plants using advanced equipment, engineering and business ideas.more » Russian power-plant engineering companies have designed such advanced power units and their equipment such as boilers, turbines, auxiliaries, process and environmental control systems similar to those produced by the world’s leading manufacturers. Their performance and ways of implementation are discussed.« less
BENCH-SCALE PROCESS EVALUATION OF REBURNING AND SORBENT INJECTION FOR IN-FURNACE NOX/SOX REDUCTION
The report gives results of combining reburning with the injection of calcium-based sorbents to investigate the potential for combined NOx and SOx reduction. Reburning, applied to pulverized-coal-fired utility boilers, involves injecting a secondary fuel above the main firing zon...
46 CFR 177.410 - Structural fire protection.
Code of Federal Regulations, 2013 CFR
2013-10-01
... not considered high fire hazards areas (galleys) as long as they do not contain medium to high heat... must be located as far as practical from heat sources. Internal combustion engine exhausts, boiler and... be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter...
46 CFR 177.410 - Structural fire protection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... considered high fire hazards areas (galleys) as long as they do not contain medium to high heat appliances... must be located as far as practical from heat sources. Internal combustion engine exhausts, boiler and... be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter...
46 CFR 177.410 - Structural fire protection.
Code of Federal Regulations, 2011 CFR
2011-10-01
... considered high fire hazards areas (galleys) as long as they do not contain medium to high heat appliances... must be located as far as practical from heat sources. Internal combustion engine exhausts, boiler and... be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter...
46 CFR 177.410 - Structural fire protection.
Code of Federal Regulations, 2012 CFR
2012-10-01
... considered high fire hazards areas (galleys) as long as they do not contain medium to high heat appliances... must be located as far as practical from heat sources. Internal combustion engine exhausts, boiler and... be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter...
46 CFR 177.410 - Structural fire protection.
Code of Federal Regulations, 2014 CFR
2014-10-01
... not considered high fire hazards areas (galleys) as long as they do not contain medium to high heat... must be located as far as practical from heat sources. Internal combustion engine exhausts, boiler and... be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter...
Control of mercury emissions from coal fired electric uitlity boilers: An update
Coal-fired power plants in the U.S. are known to be the major anthropogenic source of domestic mercury emissions. The Environmental Protection Agency (EPA) has recently proposed to reduce emissions of mercury from these plants. In March 2005, EPA plans to promulgate final regulat...
46 CFR 28.320 - Fixed gas fire extinguishing systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... only in a normally unoccupied machinery space, paint locker, or space containing flammable liquid... spaces: (1) A space containing an internal combustion engine of more than 50 horsepower; (2) A space containing an oil fired boiler; (3) An incinerator and; (4) A space containing a gasoline storage tank. (b...
46 CFR 28.320 - Fixed gas fire extinguishing systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... only in a normally unoccupied machinery space, paint locker, or space containing flammable liquid... spaces: (1) A space containing an internal combustion engine of more than 50 horsepower; (2) A space containing an oil fired boiler; (3) An incinerator and; (4) A space containing a gasoline storage tank. (b...
46 CFR 95.05-10 - Fixed fire extinguishing systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... oil units, valves, or manifolds in the line between the settling tanks and the boilers. (e) Fire... approved system must be installed in all cargo compartments and tanks for combustible cargo, except for vessels engaged exclusively in the carriage of coal or grain in bulk. For cargo compartments and tanks...
Kuang, Min; Wang, Zhihua; Zhu, Yanqun; Ling, Zhongqian; Li, Zhengqi
2014-10-21
A 600 MW(e) down-fired pulverized-coal supercritical boiler, which was equipped with a deep-air-staging combustion system for reducing the particularly high NOx emissions, suffered from the well-accepted contradiction between low NOx emissions and high carbon in fly ash, in addition to excessively high gas temperatures in the hopper that jeopardized the boiler's safe operations. Previous results uncovered that under low-NOx conditions, strengthening the staged-air effect by decreasing the staged-air angle and simultaneously increasing the staged-air damper opening alleviated the aforementioned problems to some extent. To establish low-NOx and high-burnout circumstances and control the aforementioned hopper temperatures, a further staged-air retrofit with horizontally redirecting staged air through an enlarged staged-air slot area was performed to greatly strengthen the staged-air effect. Full-load industrial-size measurements were performed to confirm the availability of this retrofit. The present data were compared with those published results before the retrofit. High NOx emissions, low carbon in fly ah, and high hopper temperatures (i.e., levels of 1036 mg/m(3) at 6% O2, 3.72%, and about 1300 °C, respectively) appeared under the original conditions with the staged-air angle of 45° and without overfire air (OFA) application. Applying OFA and reducing the angle to 20° achieved an apparent NOx reduction and a moderate hopper temperature decrease while a sharp increase in carbon in fly ash (i.e., levels of 878 mg/m(3) at 6% O2, about 1200 °C, and 9.81%, respectively). Fortunately, the present staged-air retrofit was confirmed to be applicable in regulating low-NOx, high-burnout, and low hopper temperature circumstances (i.e., levels of 867 mg/m(3) at 6% O2, 5.40%, and about 1100 °C, respectively).
NASA Astrophysics Data System (ADS)
Bala, Niraj; Singh, Harpreet; Prakash, Satya; Karthikeyan, J.
2012-01-01
High temperature corrosion accompanied by erosion is a severe problem, which may result in premature failure of the boiler tubes. One countermeasure to overcome this problem is the use of thermal spray protective coatings. In the current investigation high velocity oxy-fuel (HVOF) and cold spray processes have been used to deposit commercial Ni-20Cr powder on T22 boiler steel. To evaluate the performance of the coatings in actual conditions the bare as well as the coated steels were subjected to cyclic exposures, in the superheater zone of a coal fired boiler for 15 cycles. The weight change and thickness loss data were used to establish kinetics of the erosion-corrosion. X-ray diffraction, surface and cross-sectional field emission scanning electron microscope/energy dispersive spectroscopy (FE-SEM/EDS) and x-ray mapping techniques were used to analyse the as-sprayed and corroded specimens. The HVOF sprayed coating performed better than its cold sprayed counterpart in actual boiler environment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
DuPont, J.N.; Banovic, S.W.; Marder, A.R.
1996-08-01
Low NOx burners are being installed in many fossil fired power plants in order to comply with new Clean Air Regulations. Due to the operating characteristics of these burners, boiler tube sulfidation corrosion is often enhanced and premature tube failures can occur. Failures due to oxidation and solid particle erosion are also a concern. A program was initiated in early 1996 to evaluate the use of iron aluminide weld overlays for erosion/corrosion protection of boiler tubes in Low NOx boilers. Composite iron/aluminum wires will be used with the Gas Metal Arc Welding (GMAW) process to prepare overlays on boiler tubesmore » steels with aluminum contents from 8 to 16wt%. The weldability of the composite wires will be evaluated as a function of chemical composition and welding parameters. The effect of overlay composition on corrosion (oxidation and sulfidation) and solid particle erosion will also be evaluated. The laboratory studies will be complemented by field exposures of both iron aluminide weld overlays and co-extruded tubing under actual boiler conditions.« less
NASA Astrophysics Data System (ADS)
Chao, Xing; Jeffries, Jay B.; Hanson, Ronald K.
2013-03-01
A real-time, in situ CO sensor using 2.3 μm DFB diode laser absorption, with calibration-free wavelength-modulation-spectroscopy, was demonstrated for continuous monitoring in the boiler exhaust of a pulverized-coal-fired power plant up to temperatures of 700 K. The sensor was similar to a design demonstrated earlier in laboratory conditions, now refined to accommodate the harsh conditions of utility boilers. Measurements were performed across a 3 m path in the particulate-laden economizer exhaust of the coal-fired boiler. A 0.6 ppm detection limit with 1 s averaging was estimated from the results of a continuous 7-h-long measurement with varied excess air levels. The measured CO concentration exhibited expected inverse trends with the excess O2 concentration, which was varied between 1 and 3 %. Measured CO concentrations ranged between 6 and 200 ppm; evaluation of the data suggested a dynamic range from 6 to 10,000 ppm based on a minimum signal-to-noise ratio of ten and maximum absorbance of one. This field demonstration of a 2.3 μm laser absorption sensor for CO showed great potential for real-time combustion exhaust monitoring and control of practical combustion systems.
Small, modular, low-cost coal-fired power plants for the international market
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zauderer, B.; Frain, B.; Borck, B.
1997-12-31
This paper presents recent operating results of Coal Tech`s second generation, air cooled, slagging coal combustor, and its application to power plants in the 1 to 20 MW range. This 20 MMBtu/hour combustor was installed in a new demonstration plant in Philadelphia, PA in 1995. It contains the combustion components of a 1 MWe coal fired power plant, a 17,500 lb/hour steam boiler, coal storage and feed components, and stack gas cleanup components. The plant`s design incorporates improvements resulting from 2,000 hours of testing between 1987 and 1993 on a first generation, commercial scale, air cooled combustor of equal thermalmore » rating. Since operations began in early 1996, a total of 51 days of testing have been successfully completed. Major results include durability of the combustor`s refractory wall, excellent combustion with high ash concentration in the fuel, removal of 95% to 100% of the slag in the combustor, very little ash deposition in the boiler, major reduction of in-plant parasitic power, and simplified power system control through the use of modular designs of sub-systems and computer control. Rapid fuel switching between oil, gas, and coal and turndown of up to a factor of three was accomplished. All these features have been incorporated in advanced coal fired plant designs in the 1 to 20 MWe range. Incremental capital costs are only $100 to $200/kW higher than comparable rated gas or oil fired steam generating systems. Most of its components and subsystems can be factory assembled for very rapid field installation. The low capital, low operating costs, fuel flexibility, and compatibility with very high ash fuels, make this power system very attractive in regions of the world having domestic supplies of these fuels.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hughes, E.; Tillman, D.
1997-12-01
Cofiring is considered to be the most promising near-term approach to fossil C0{sub 2} emissions mitigation through biomass usage. Consequently FETC and EPRI have entered into a cooperative agreement: `Cofiring Biomass and Waste-Derived fuels in Electric Utility Coal- Fired Boilers.` This agreement supports sixteen (16) EPRI research projects, each contributing to the commercialization of systems to address greenhouse gas emissions. These projects include: (1) cofiring combustion testing at the Seward Generating Station of GPU Genco; (2) fuel preparation testing at the Greenidge Generating Station of NYSEG; (3) precommercial testing of cofiring at the Allen and Colbert Fossil Plants of TVA;more » (4) testing of switchgrass cofiring at the Blount St. Station of Madison Gas & Electric; (5) high percentage biomass cofiring with Southern Company; (6) urban wood waste cofiring at the supercritical cyclone boiler at Michigan City Generating Station of Northern Indiana Public Service Co. (NIPSCO); (7) evaluation of switchgrass cofiring with Nebraska Public Power District at Sandia National Laboratories in Livermore, CA; (8) waste plastics cofiring with Duke Power in a tangentially-fired pulverized coal (PC) boiler; (9) cofiring a mixture of plastics, fiber, and pulp industry wastes with South Carolina Electric and Gas; (10) urban wood waste cofiring evaluation and testing by the University of Pittsburgh in stoker boilers; (11) assessment of toxic emissions from cofiring of wood and coal; (12) development of fuel and power plant models for analysis and interpretation of cofiring results; (13) analysis of C0{sub 2} utilization in algal systems for wastewater treatment; (14) combustion testing and combustor development focusing on high percentage cofiring; (15) analysis of problems and potential solutions to the sale of flyash from coal-fired boilers practicing cofiring; and (16) analysis of C0{sub 2} capture and disposal systems. During the second quarter of this contract, from January 1, 1997 through March 31, 1997, significant progress has been made on these projects. This progress focuses upon analysis of data from the cofiring tests, construction of systems to promote additional cofiring tests, and initiation of tasks evaluating alternatives to cofiring. This report contains a brief description of the progress made during the second quarter of the contract, focusing upon test results from the Seward Generating Station, where parametric testing at a wall-fired PC boiler was used to evaluate cofiring using separate feeding of wood and coal to the energy generation system.« less
Coal-fired boiler houses in Cracow present state and possibilities to improve their efficiency
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cyklis, P.; Butcher, T.A.
1995-12-31
A significant amount of heat energy both for heating and process purposes is generated in Cracow, Poland in small-and medium size local boiler houses. The operating procedure of these boiler houses is most often economically and ecologically ineffective because of the bad condition of boilers and lack of funds to install automation, control and measurement equipment. Within the Polish-American Program of Elimination of Low Emission Sources financed by the US Department of Energy, the ENERGOEKSPERT Co., Ltd. investigated chosen boiler houses in Cracow, commissioned by the Cracow Development Office. The results of these investigations were subject of engineering analysis carriedmore » out at the Institute of Industrial Equipment and Power Engineering, Technical University, Cracow. The analysis proved that the low-cost improvement of economic efficiency and reduction of air pollutant emission is feasible for combustion of coal fuels.« less
Kuang, Min; Li, Zhengqi; Liu, Chunlong; Zhu, Qunyi
2013-05-07
To achieve significant reductions in NOx emissions and to eliminate strongly asymmetric combustion found in down-fired boilers, a deep-air-staging combustion technology was trialed in a down-fired 600 MWe supercritical utility boiler. By performing industrial-sized measurements taken of gas temperatures and species concentrations in the near wing-wall region, carbon in fly ash and NOx emissions at various settings, effects of overfire air (OFA) and staged-air damper openings on combustion characteristics, and NOx emissions within the furnace were experimentally determined. With increasing the OFA damper opening, both fluctuations in NOx emissions and carbon in fly ash were initially slightly over OFA damper openings of 0-40% but then lengthened dramatically in openings of 40-70% (i.e., NOx emissions reduced sharply accompanied by an apparent increase in carbon in fly ash). Decreasing the staged-air declination angle clearly increased the combustible loss but slightly influenced NOx emissions. In comparison with OFA, the staged-air influence on combustion and NOx emissions was clearly weaker. Only at a high OFA damper opening of 50%, the staged-air effect was relatively clear, i.e., enlarging the staged-air damper opening decreased carbon in fly ash and slightly raised NOx emissions. By sharply opening the OFA damper to deepen the air-staging conditions, although NOx emissions could finally reduce to 503 mg/m(3) at 6% O2 (i.e., an ultralow NOx level for down-fired furnaces), carbon in fly ash jumped sharply to 15.10%. For economical and environment-friendly boiler operations, an optimal damper opening combination (i.e., 60%, 50%, and 50% for secondary air, staged-air, and OFA damper openings, respectively) was recommended for the furnace, at which carbon in fly ash and NOx emissions attained levels of about 10% and 850 mg/m(3) at 6% O2, respectively.
Study of the possibility of thermal utilization of contaminated water in low-power boilers
NASA Astrophysics Data System (ADS)
Roslyakov, P. V.; Proskurin, Y. V.; Zaichenko, M. N.
2017-09-01
The utilization of water contaminated with oil products is a topical problem for thermal power plants and boiler houses. It is reasonable to use special water treatment equipment only for large power engineering and industry facilities. Thermal utilization of contaminated water in boiler furnaces is proposed as an alternative version of its utilization. Since there are hot-water fire-tube boilers at many enterprises, it is necessary to study the possibility of thermal utilization of water contaminated with oil products in their furnaces. The object of this study is a KV-GM-2.0 boiler with a heating power of 2 MW. The pressurized burner developed at the Moscow Power Engineering Institute, National Research University, was used as a burner device for supplying liquid fuel. The computational investigations were performed on the basis of the computer simulation of processes of liquid fuel atomization, mixing, ignition, and burnout; in addition, the formation of nitrogen oxides was simulated on the basis of ANSYS Fluent computational dynamics software packages, taking into account radiative and convective heat transfer. Analysis of the results of numerical experiments on the combined supply of crude oil and water contaminated with oil products has shown that the thermal utilization of contaminated water in fire-tube boilers cannot be recommended. The main causes here are the impingement of oil droplets on the walls of the flame tube, as well as the delay in combustion and increased emissions of nitrogen oxides. The thermal utilization of contaminated water combined with diesel fuel can be arranged provided that the water consumption is not more than 3%; however, this increases the emission of nitrogen oxides. The further increase in contaminated water consumption will lead to the reduction of the reliability of the combustion process.
Field Test of Boiler Primary Loop Temperature Controller
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glanville, P.; Rowley, P.; Schroeder, D.
Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoring (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. For hydronic boilers specifically, these devices perform load monitoring, with continuous measurement of supply and in some cases return water temperatures. Energy savings from these ALM controllers are derived from dynamic management of the boiler differential, where a microprocessor with memory of past boiler cycles prevents the boiler from firing for a period of time, to limit cycling losses and inefficient operation duringmore » perceived low load conditions. These differ from OTR controllers, which vary boiler setpoint temperatures with ambient conditions while maintaining a fixed differential. PARR installed and monitored the performance of one type of ALM controller, the M2G from Greffen Systems, at multifamily sites in the city of Chicago and its suburb Cary, IL, both with existing OTR control. Results show that energy savings depend on the degree to which boilers are over-sized for their load, represented by cycling rates. Also savings vary over the heating season with cycling rates, with greater savings observed in shoulder months. Over the monitoring period, over-sized boilers at one site showed reductions in cycling and energy consumption in line with prior laboratory studies, while less over-sized boilers at another site showed muted savings.« less
[The utility boiler low NOx combustion optimization based on ANN and simulated annealing algorithm].
Zhou, Hao; Qian, Xinping; Zheng, Ligang; Weng, Anxin; Cen, Kefa
2003-11-01
With the developing restrict environmental protection demand, more attention was paid on the low NOx combustion optimizing technology for its cheap and easy property. In this work, field experiments on the NOx emissions characteristics of a 600 MW coal-fired boiler were carried out, on the base of the artificial neural network (ANN) modeling, the simulated annealing (SA) algorithm was employed to optimize the boiler combustion to achieve a low NOx emissions concentration, and the combustion scheme was obtained. Two sets of SA parameters were adopted to find a better SA scheme, the result show that the parameters of T0 = 50 K, alpha = 0.6 can lead to a better optimizing process. This work can give the foundation of the boiler low NOx combustion on-line control technology.
Economic considerations in coverting from oil/gas firing to coal
NASA Technical Reports Server (NTRS)
Rau, J. G.
1978-01-01
Economic considerations involved in fuel conversion such as from oil and/or gas firing to coal are discussed including investments costs for new facilities and equipment (including air pollution control equipment), operation and maintenance costs, and purchased fuel costs. An analytical approach to assessing the cost effectiveness of fuel conversion in terms of the annual net cost of conversion, the equivalent annual number of barrels of oil saved, and the integral rate of return of the conversion investment is presented. Illustrative numerical examples are presented for typical utility boilers and industrial boiler facilities. A further consideration addressed deals with the impacts of these costs on the overall financial structure of the firm and the ability of the firm to raise the necessary investment captial.
López-Vilariño, J M; Fernández-Martínez, G; Turnes-Carou, I; Muinategui-Lorenzo, S; López-Mahía, P; Prada-Rodríguez, D
2003-06-01
Behavior and contents of fluorine and chlorine in coal feedstock, combustion wastes (slag and fly ash) and emissions were studied in five conventional coal fired power plants and in a fluidized bed coal power plant. The halide levels found in the used coal were quite low. Mass balances and emission factors were calculated. The volatility of these elements makes the gaseous emission the main target between the residues. The influence of combustion parameters is not clearly established. Several analytical techniques (ion selective electrodes, capillary electrophoresis and ion chromatography) are employed to determinate the halide concentration in the different samples taken in the power plants studied (coal, slag, fly ash and flue gases).
Workshop proceedings: U-bend tube cracking in steam generators
NASA Astrophysics Data System (ADS)
Shoemaker, C. E.
1981-06-01
A design to reduce the rate of tube failure in high pressure feedwater heaters, a number of failed drawn and stress relieved Monel 400 U-bend tubes removed from three high pressure feedwater heaters was examined. Steam extracted from the turbine is used to preheat the boiler feedwater in fossil fuel fired steam plants to improve thermal efficiency. This is accomplished in a series of heaters between the condenser hot well and the boiler. The heaters closest to the boiler handle water at high pressure and temperature. Because of the severe service conditions, high pressure feedwater heaters are frequently tubed with drawn and stress relieved Monel 400.
Development of a Permitting Strategy for a Coal-Fired Heating Plant, K.I. Sawyer AFB, Maine.
1982-12-01
that the proposed control system is BACT for controlling total suspended particulates. Under PSD review for SO2, application of BACT might require flue ... gas desulfurization and/or burning low sulfur coal. One solution to avoid BACT review for SO2 would be to limit the sulfur content of coal...existing five boilers. 3-23 i. _ - -’••-’•-’-"«--• .-*.’-.’. and combustion air at a maximum of 350°F. The corresponding flue gas exit temperature
This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.
Air Emissions Inventory Guidance Document for Stationary Sources at Air Force Installations.
1999-05-01
small stoker-fired boilers). sox Change to lower sulfur coal, Coal Cleaning, Flue Gas Desulfurization (e.g., wet scrubbing, spray drying, furnace...Multiclone Collector. SOx Flue Gas Desulfurization (e.g., wet , semi-dry, or dry scrubbers) NOx Low Excess Air, Burners out of Service, Biased Burner...both flue gas desulfurization spray dryer adsorber (FGD-SDA) and a fabric filter (FF). d Factors apply to boilers equipped with an electrostatic
Homogenous and heterogeneous combustion in the secondary chamber of a straw-fired batch boiler
NASA Astrophysics Data System (ADS)
Szubel, Mateusz; Adamczyk, Wojciech; Basista, Grzegorz; Filipowicz, Mariusz
Currently, the attention of the producers of biomass batch boilers is mostly focused on the problem of the total efficiency of energy conversion, CO emissions as well as particulate matter emissions. Due to the regulations of the European Union, the emissions referred to above have to be kept at certain levels because of health considerations, but also because of the necessity to increase the efficiency of the devices. The paper presents the process of analysis of a straw-fired small-scale boiler. In this study, the early stage CFD model presented in a previous paper [1] has been improved and evaluated. Based on [2], an additional set of specimens participating in homogeneous gas reactions was assumed to describe the combustion process sufficiently. Associated Arrhenius parameters have been applied for the description of these reactions. ANSYS Fluent 16 has been used to perform the analysis and the analysis was focused on the CO emissions level as well as on the impact of the modelling approach on the result of the computing. Moreover, losses related to incomplete combustion have been calculated for each of the considered cases.
NASA Astrophysics Data System (ADS)
Huang, Jun-Lin; Zhou, Ke-Yi; Wang, Xin-Meng; Tu, Yi-You; Xu, Jian-Qun
2014-07-01
Failure of steam-side oxide scales on boiler tubes can seriously influence the safety of coal-fired power plants. Uniaxial tensile tests employing acoustic emission (AE) monitoring were performed, in this work, to investigate the failure behavior of steam-side oxide scales on T22 alloy boiler superheater tubes. The characteristic frequency spectra of the captured AE signals were obtained by performing fast Fourier transform. Three distinct peak frequency bands, 100-170, 175-250, and 280-390 kHz, encountered in different testing stages were identified in the frequency spectra, which were confirmed to, respectively, correspond to substrate plastic deformation, oxide vertical cracking, and oxide spalling with the aid of scanning electronic microscopy observations, and can thus be used for distinguishing different oxide failure mechanisms. Finally, the critical cracking strain of the oxide scale and the interfacial shear strength of the oxide/substrate interface were estimated, which are the critical parameters urgently desired for modeling the failure behavior of steam-side oxide scales on boiler tubes of coal-fired power plants.
The report discusses tests conducted at EPA's Air Pollution Prevention and Control Division to evaluate the effects of changing coals on emissions of metal hazardous air pollutants from coal-fired boilers. Six coals were burned in a 29 kW (100,000 Btu/hr) down-fired combustor und...
Coal Utilization in Schools: Issues and Answers.
ERIC Educational Resources Information Center
Pusey, Robert H.
Coal, at one-third the cost of natural gas and one-fifth the cost of oil, is our cheapest source of energy and is also in abundant supply. Because of significant technological advances, coal-fired equipment now approaches the clean and automatic operational characteristics of gas- and oil-fired boilers. For these reasons, and because schools are…
7. Detail, 1885 Sanborn Fire Insurance Map, Carlin, Nevada, in ...
7. Detail, 1885 Sanborn Fire Insurance Map, Carlin, Nevada, in collection of Nevada Historical Society, Reno; credit Nevada Historical Society. Engine Stores Building is adjacent to R.R. Repair Shop, and is shown containing Library, Cooper Shop, Office, Ware Room, and Boiler & Engine Room. - Southern Pacific Railroad, Carlin Shops, Foot of Sixth Street, Carlin, Elko County, NV
Åmand, Lars-Erik; Kassman, Håkan
2013-08-01
Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) are formed during waste incineration and in waste-to-energy boilers. Incomplete combustion, too short residence times at low combustion temperatures (<700 °C), incineration of electronic waste and plastic waste containing chlorine are all factors influencing the formation of PCDD/Fs in boilers. The impact of chlorine and catalysing metals (such as copper and iron) in the fuel on PCDD/F formation was studied in a 12 MW(th) circulating fluidised bed (CFB) boiler. The PCDD/F concentrations in the raw gas after the convection pass of the boiler and in the fly ashes were compared. The fuel types were a so-called clean biomass with low content of chlorine, biomass with enhanced content of chlorine from supply of PVC, and solid recovered fuel (SRF) which is a waste fuel containing higher concentrations of both chlorine, and catalysing metals. The PCDD/F formation increased for the biomass with enhanced chlorine content and it was significantly reduced in the raw gas as well as in the fly ashes by injection of ammonium sulphate. A link, the alkali chloride track, is demonstrated between the level of alkali chlorides in the gas phase, the chlorine content in the deposits in the convection pass and finally the PCDD/F formation. The formation of PCDD/Fs was also significantly reduced during co-combustion of SRF with municipal sewage sludge (MSS) compared to when SRF was fired without MSS as additional fuel. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Knightly, W. F.
1980-01-01
About fifty industrial processes from the largest energy consuming sectors were used as a basis for matching a similar number of energy conversion systems that are considered as candidate which can be made available by the 1985 to 2000 time period. The sectors considered included food, textiles, lumber, paper, chemicals, petroleum, glass, and primary metals. The energy conversion systems included steam and gas turbines, diesels, thermionics, stirling, closed cycle and steam injected gas turbines, and fuel cells. Fuels considered were coal, both coal and petroleum based residual and distillate liquid fuels, and low Btu gas obtained through the on site gasification of coal. Computer generated reports of the fuel consumption and savings, capital costs, economics and emissions of the cogeneration energy conversion systems (ECS's) heat and power matched to the individual industrial processes are presented. National fuel and emissions savings are also reported for each ECS assuming it alone is implemented. Two nocogeneration base cases are included: coal fired and residual fired process boilers.
NASA Technical Reports Server (NTRS)
Knightly, W. F.
1980-01-01
About fifty industrial processes from the largest energy consuming sectors were used as a basis for matching a similar number of energy conversion systems that are considered as candidate which can be made available by the 1985 to 2000 time period. The sectors considered included food, textiles, lumber, paper, chemicals, petroleum, glass, and primary metals. The energy conversion systems included steam and gas turbines, diesels, thermionics, stirling, closed cycle and steam injected gas turbines, and fuel cells. Fuels considered were coal, both coal and petroleum based residual and distillate liquid fuels, and low Btu gas obtained through the on site gasification of coal. Computer generated reports of the fuels consumption and savings, capital costs, economics and emissions of the cogeneration energy conversion systems (ECS's) heat and power matched to the individual industrial processes are presented. National fuel and emissions savings are also reported for each ECS assuming it alone is implemented. Two nocogeneration base cases are included: coal fired and residual fired process boilers.
NASA Technical Reports Server (NTRS)
Knightly, W. F.
1980-01-01
About fifty industrial processes from the largest energy consuming sectors were used as a basis for matching a similar number of energy conversion systems that are considered as candidate which can be made available by the 1985 to 2000 time period. The sectors considered included food, textiles, lumber, paper, chemicals, petroleum, glass, and primary metals. The energy conversion systems included steam and gas turbines, diesels, thermionics, stirling, closed cycle and steam injected gas turbines, and fuel cells. Fuels considered were coal, both coal and petroleum based residual and distillate liquid fuels, and low Btu gas obtained through the on site gasification of coal. Computer generated reports of the fuel consumption and savings, capital costs, economics and emissions of the cogeneration energy conversion systems (ECS's) heat and power matched to the individual industrial processes are presented. National fuel and emissions savings are also reported for each ECS assuming it alone is implemented. Two nocogeneration base cases are included: coal fired and residual fired process boilers.
NASA Astrophysics Data System (ADS)
Kirillov, M. V.; Safronov, P. G.
2014-07-01
Efficiency of coal-fired boilers is determined in many respects by optimal operation of the coal-pulverizing plants that are increasingly frequently equipped with pulverizing fans. By an example of retrofitted MV-3300/800/490 pulverizing fans, the effects of different factors on the performance and economic efficiency of the coal-pulverizing plants are analyzed. The experience gained in retrofitting MV-3300/800/490 pulverizing fans by introducing the three-crusher operation mode of a TPE-216 boiler employing the internal recirculation and a blading device in the classifier was also studied. Optimization of the boiler's operation mode was made when switching over from the four-crusher to the three-crusher mode, which considerably improved the engineering and economic characteristics.
Li, Zhengqi; Zhao, Wei; Li, Ruiyang; Wang, Zhenwang; Li, Yuan; Zhao, Guangbo
2009-04-01
Measurements were taken for a 35-ton-per-hour biomass-fired travelling grate boiler. Local mean concentrations of O(2), CO, SO(2) and NO gas species and gas temperatures were determined in the region above the grate. For a 28-ton-per-hour load, the mass ratios of biomass fly ash and boiler slag were 42% and 58%, the boiler efficiency was 81.56%, and the concentrations of NO(x) and SO(2) at 6% O(2) were 257 and 84 mg/m(3). For an 18-ton-per-hour load, the fuel burning zone was nearer to the inlet than it was for the 28-ton-per-hour load, and the contents of CO and NO in the fuel burning zone above the grate were lower.
DOE Office of Scientific and Technical Information (OSTI.GOV)
PARR
Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoring (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. For hydronic boilers specifically, these devices perform load monitoring, with continuous measurement of supply and in some cases return water temperatures. Energy savings from these ALM controllers are derived from dynamic management of the boiler differential, where a microprocessor with memory of past boiler cycles prevents the boiler from firing for a period of time, to limit cycling losses and inefficient operation duringmore » perceived low load conditions. These differ from OTR controllers, which vary boiler setpoint temperatures with ambient conditions while maintaining a fixed differential. PARR installed and monitored the performance of one type of ALM controller, the M2G from Greffen Systems, at multifamily sites in the city of Chicago and its suburb Cary, IL, both with existing OTR control. Results show that energy savings depend on the degree to which boilers are over-sized for their load, represented by cycling rates. Also savings vary over the heating season with cycling rates, with greater savings observed in shoulder months. Over the monitoring period, over-sized boilers at one site showed reductions in cycling and energy consumption in line with prior laboratory studies, while less over-sized boilers at another site showed muted savings.« less
Credit BG. View looking southwest at Test Stand "D" complex. ...
Credit BG. View looking southwest at Test Stand "D" complex. In the background at left is the Steam Generator Plant 4280/E-81 built in 1972 to house four gas-fired Clayton flash boilers. The boilers were later supplemented by the electrically heated steam accumulator (sphere) to supply steam to the various ejectors at Test Stand "D" vacuum test cells - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA
Ranking of Air Force Heating Plants Relative to the Economic Benefit of Coal Utilization
1989-11-01
HTlW Output Capacity ..................... 27 5.2.2 Combustion Technologies ......................... 31 5.3 COMPUTER MODEL FOR LCC ANALISIS ...and field-erected units have been examined. The packaged units are factory -built, shell (fire-tube) boilers that are small enotgh to be shipped by...40 HBtMu/h with a thermal energy capacity factory of about 65% if used as a baseload heating plant. A water- tube boiler with a steam rating of 1200
1989-06-01
FLUE GAS DESULFURIZATION EVALUATION A-1/A-2 3-1. 3 BOILER STACK EMISSION CONTROL WITH...Appendices A - BACT Flue Gas Desulfurization Evaluation B - BACT Off- Gas Refrigeration Evaluation v LIST OF FIGURES Figure Page 1. Material Balance for...2. Desulfurize the flue gases from the Riley boilers when firing with high sulfur oils or lignite. Options in this category include commercial wet
40 CFR 49.124 - Rule for limiting visible emissions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... by any Federal, Tribal, State, or local government, and emissions from fuel combustion in mobile... vehicle, nonroad engine, nonroad vehicle, oil-fired boiler, opacity, open burning, particulate matter...
40 CFR 49.124 - Rule for limiting visible emissions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... by any Federal, Tribal, State, or local government, and emissions from fuel combustion in mobile... vehicle, nonroad engine, nonroad vehicle, oil-fired boiler, opacity, open burning, particulate matter...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilhelm, B.
1996-12-31
Information is presented on a 110 MWe atmospheric CFB located in the Czech Republic firing brown coal. The following topics are discussed: fuel analysis; boiler design parameters; CFB fluidizing nozzle; and project time schedule. Information is also given on a 200 MWe atmospheric CFB located in the Republic of Korea firing Korean anthracite. Data are presented on fuel specifications; predicted performance; and engineering and construction schedule.
The reduction of divalent gaseous mercury (HgII) to elemental gaseous mercury (Hg0) in a commercial coal-fired power plant (CFPP)exhaust plume was investigated by simultaneous measurement in-stack and in-plume as part of a collaborative study among the U.S....
Guo, Yang; Tian, Jinping; Chertow, Marian; Chen, Lujun
2016-10-03
Mitigating greenhouse gas (GHG) emissions in China's industrial sector is crucial for addressing climate change. We developed a vintage stock model to quantify the GHG mitigation potential and cost effectiveness in Chinese eco-industrial parks by targeting energy infrastructure with five key measures. The model, integrating energy efficiency assessments, GHG emission accounting, cost-effectiveness analyses, and scenario analyses, was applied to 548 units of energy infrastructure in 106 parks. The results indicate that two measures (shifting coal-fired boilers to natural gas-fired boilers and replacing coal-fired units with natural gas combined cycle units) present a substantial potential to mitigate GHGs (42%-46%) compared with the baseline scenario. The other three measures (installation of municipal solid waste-to-energy units, replacement of small-capacity coal-fired units with large units, and implementation of turbine retrofitting) present potential mitigation values of 6.7%, 0.3%, and 2.1%, respectively. In most cases, substantial economic benefits also can be achieved by GHG emission mitigation. An uncertainty analysis showed that enhancing the annual working time or serviceable lifetime levels could strengthen the GHG mitigation potential at a lower cost for all of the measures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Åmand, Lars-Erik; Kassman, Håkan, E-mail: hakan.kassman@vattenfall.com
2013-08-15
Highlights: • Two strategies to reduce PCDD/F formation when co-firing solid recovered fuel (SRF) and biomass. • They were co-combustion with municipal sewage sludge (MSS) and addition of ammonium sulphate. • PCDD/Fs were significantly reduced for a biomass rich in chlorine when adding ammonium sulphate. • MSS had a suppressing effect on PCDD/F formation during co-combustion with SRF. • A link is presented between gaseous alkali chlorides, chlorine in deposits and PCDD/F formation. - Abstract: Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) are formed during waste incineration and in waste-to-energy boilers. Incomplete combustion, too short residence times at low combustionmore » temperatures (<700 °C), incineration of electronic waste and plastic waste containing chlorine are all factors influencing the formation of PCDD/Fs in boilers. The impact of chlorine and catalysing metals (such as copper and iron) in the fuel on PCDD/F formation was studied in a 12 MW{sub th} circulating fluidised bed (CFB) boiler. The PCDD/F concentrations in the raw gas after the convection pass of the boiler and in the fly ashes were compared. The fuel types were a so-called clean biomass with low content of chlorine, biomass with enhanced content of chlorine from supply of PVC, and solid recovered fuel (SRF) which is a waste fuel containing higher concentrations of both chlorine, and catalysing metals. The PCDD/F formation increased for the biomass with enhanced chlorine content and it was significantly reduced in the raw gas as well as in the fly ashes by injection of ammonium sulphate. A link, the alkali chloride track, is demonstrated between the level of alkali chlorides in the gas phase, the chlorine content in the deposits in the convection pass and finally the PCDD/F formation. The formation of PCDD/Fs was also significantly reduced during co-combustion of SRF with municipal sewage sludge (MSS) compared to when SRF was fired without MSS as additional fuel.« less
Basic Information about Mercury
... Since mercury occurs naturally in coal and other fossil fuels, when people burn these fuels for energy, ... coal-fired boilers in many industries to generate forms of thermal heat like steam The burning of ...
46 CFR 62.35-20 - Oil-fired main boilers.
Code of Federal Regulations, 2012 CFR
2012-10-01
... to prevent pocketing and explosive accumulations of combustible gases. (iii) The burner igniter must... of automatic detection of unsafe trip conditions. (h) Burner safety trip control system. (1) Each...
46 CFR 62.35-20 - Oil-fired main boilers.
Code of Federal Regulations, 2014 CFR
2014-10-01
... to prevent pocketing and explosive accumulations of combustible gases. (iii) The burner igniter must... of automatic detection of unsafe trip conditions. (h) Burner safety trip control system. (1) Each...
46 CFR 62.35-20 - Oil-fired main boilers.
Code of Federal Regulations, 2011 CFR
2011-10-01
... to prevent pocketing and explosive accumulations of combustible gases. (iii) The burner igniter must... of automatic detection of unsafe trip conditions. (h) Burner safety trip control system. (1) Each...
46 CFR 62.35-20 - Oil-fired main boilers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... to prevent pocketing and explosive accumulations of combustible gases. (iii) The burner igniter must... of automatic detection of unsafe trip conditions. (h) Burner safety trip control system. (1) Each...
46 CFR 62.35-20 - Oil-fired main boilers.
Code of Federal Regulations, 2013 CFR
2013-10-01
... to prevent pocketing and explosive accumulations of combustible gases. (iii) The burner igniter must... of automatic detection of unsafe trip conditions. (h) Burner safety trip control system. (1) Each...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saqib, Naeem, E-mail: naeem.saqib@oru.se; Bäckström, Mattias, E-mail: mattias.backstrom@oru.se
Highlights: • Different solids waste incineration is discussed in grate fired and fluidized bed boilers. • We explained waste composition, temperature and chlorine effects on metal partitioning. • Excessive chlorine content can change oxide to chloride equilibrium partitioning the trace elements in fly ash. • Volatility increases with temperature due to increase in vapor pressure of metals and compounds. • In Fluidized bed boiler, most metals find themselves in fly ash, especially for wood incineration. - Abstract: Trace element partitioning in solid waste (household waste, industrial waste, waste wood chips and waste mixtures) incineration residues was investigated. Samples of flymore » ash and bottom ash were collected from six incineration facilities across Sweden including two grate fired and four fluidized bed incinerators, to have a variation in the input fuel composition (from pure biofuel to mixture of waste) and different temperature boiler conditions. As trace element concentrations in the input waste at the same facilities have already been analyzed, the present study focuses on the concentration of trace elements in the waste fuel, their distribution in the incineration residues with respect to chlorine content of waste and combustion temperature. Results indicate that Zn, Cu and Pb are dominating trace elements in the waste fuel. Highly volatile elements mercury and cadmium are mainly found in fly ash in all cases; 2/3 of lead also end up in fly ash while Zn, As and Sb show a large variation in distribution with most of them residing in the fly ash. Lithophilic elements such as copper and chromium are mainly found in bottom ash from grate fired facilities while partition mostly into fly ash from fluidized bed incinerators, especially for plants fuelled by waste wood or ordinary wood chips. There is no specific correlation between input concentration of an element in the waste fuel and fraction partitioned to fly ash. Temperature and chlorine content have significant effects on partitioning characteristics by increasing the formation and vaporization of highly volatile metal chlorides. Zinc and cadmium concentrations in fly ash increase with the incineration temperature.« less
Development of super-clean diesel engine and combustor using nonthermal plasma hybrid aftertreatment
NASA Astrophysics Data System (ADS)
Okubo, Masaaki
2015-10-01
One of important and successful environmental applications of atmospheric-pressure corona discharge or plasma is electrostatic precipitator (ESP), which have been widely used for coal- or oil-fired boilers in electric power plants and particulate matter control emitted from industries such as glass melting furnace system, etc. In the ESPs, steady high voltage is usually applied to a pair of electrodes (at least, one of these has sharp edge). Unsteady pulsed high voltage is often applied for the collection of high-resistivity particulate matter (PM) to avoid reverse corona phenomena which reduce the collection efficiency of the ESPs. It was found that unsteady high voltage can treat hazardous gaseous components (NOx, SOx, hydrocarbon, and CO, etc.) in the exhaust gas, and researches were shifted from PM removal to hazardous gases aftertreatment with unsteady corona discharge induced plasmas. In the paper, recent results on diesel engine and industrial boiler emission controls are mainly reviewed among these our research topics.
Engineering evaluation of the use of the Timberline condensing economizer for particulate collection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Butcher, T.; Serry, H.
1980-12-01
The possible use of the Timberline Industries condensing economizer as a particulate collection device on commercial sector boilers which are being converted to coal-oil mixture (COM) firing has been considered. The saturation temperature of the water vapor in the flue gas has been estimated as a function of excess air and ambient relative humidity. Also, boiler stack losses have been estimated for a variety of operating conditions including stack temperatures below the dew point. The condensing economizer concept will be limited to applications which can use the low temperature heat including water heating and forced air space heating. The potentialmore » particulate collection efficiency, water disposal, and similar heat recovery devices are discussed. A cost analysis is presented which indicates that the economizer system is not competitive with a cyclone but is competitive with a baghouse. The use of the cyclone is limited by collection efficiency. The measurement of COM flyash particle size distribution is recommended.« less
Port Graham Community Building Biomass Heating Design Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Norman, Patrick; Sink, Charles
Native Village of Port Graham completed preconstruction activities to prepare for construction and operations of a cord wood biomass heating system to five or more community buildings in Port Graham, Alaska. Project Description Native Village of Port Graham (NVPG) completed preconstruction activities that pave the way towards reduced local energy costs through the construction and operations of a cord wood biomass heating system. NVPG plans include installation of a GARN WHS 3200 Boiler that uses cord wood as fuel source. Implementation of the 700,000 Btu per hour output biomass community building heat utility would heat 5-community buildings in Port Graham,more » Alaska. Heating system is estimated to displace 85% of the heating fuel oil or 5365 gallons of fuel on an annual basis with an estimated peak output of 600,000 Btu per hour. Estimated savings is $15,112.00 per year. The construction cost estimate made to install the new biomass boiler system is estimated $251,693.47 with an additional Boiler Building expansion cost estimated at $97,828.40. Total installed cost is estimated $349,521.87. The WHS 3200 Boiler would be placed inside a new structure at the old community Water Plant Building site that is controlled by NVPG. Design of the new biomass heat plant and hot water loop system was completed by Richmond Engineering, NVPG contractor for the project. A hot water heat loop system running off the boiler is designed to be placed underground on lands controlled by NVPG and stubbed to feed hot water to existing base board heating system in the following community buildings: 1. Anesia Anahonak Moonin Health and Dental Clinic 2. Native Village of Port Graham offices 3. Port Graham Public Safety Building/Fire Department 4. Port Graham Corporation Office Building which also houses the Port Graham Museum and Head Start Center 5. North Pacific Rim Housing Authority Workshop/Old Fire Hall Existing community buildings fuel oil heating systems are to be retro-fitted to accommodate hot water from the proposed wood-burning GARN Boiler, once installed, and rely on the existing fuel oil-fired hot water heating equipment for backup. The boiler would use an estimated 125 bone dry tons, equivalent to 100 cords, woody biomass feedstock obtained from local lands per year. Project would use local labor as described in the Port Graham Biomass Project, report completed by Chena Power, Inc. and Winters and Associates as part of the in-kind support to the U. S. Department of Energy (DOE) project for work on a project for State of Alaska’s Alaska Energy Authority (AEA). NVPG will likely initiate operations of the biomass boiler system even though several operational variations were studied. Obtaining the fuel source could be done by contractors, PGVC employees, or NVPG employees. Feeding the system would likely be done by NVPG employees. A majority of the buildings heated would be owned by NVPG. The PGVC office would be heated as well as the Old Fire Hall used as a workshop and storage area for North Pacific Rim Housing Authority. One methodology studied to charge for cost of utilizing the community building biomass system would use a percentage of use of hot water generated by the biomass hot water system based on past heating oil usage in relation to all buildings heated by biomass hot water. The method is better described in the Port Graham Biomass Project report. Fuel source agreements have been drafted to enter into agreements with area landowners. One Native allotment owner has asked Chugachmiut Forestry to begin a timber sale process to sell timber off her lands, specifically wind thrown timber that was determined to be of sufficient quantity to supply to the proposed biomass heating system for approximately 5-years. On NVPG’s behalf, Chugachmiut has presented to PGVC three different documents, attached, that could lead to a sale of woody biomass fuel for the project for up to 25-years, the expected life of the project. PGVC has signed a letter of intent to negotiate a sale of woody biomass material April 30, 2015. Chugachmiut Forestry has conducted two different field forest measurements of Native allotment lands and PGVC forest and timber lands. Lands deemed road accessible for biomass harvest were analyzed for this project. Forestry then conducted three different analyses and developed two reports to determine forest biomass on a tons per acre basis in addition to timber volume measurements taken for forest management purposes. Permits required were limited. For the biomass building, the Kenai Peninsula Borough did not require a permit. State of Alaska, Department of Public Safety, Division of Fire and Life Safety requires a plan review for fire and life safety requirements called an application for Fire and Life Safety Plan Review that would require a registered design professional to sign the document. State of Alaska State Forest Practices Act is required to be followed for any timber sale or harvest. This Act also requires consultation with Alaska Department of Fish and Game when operations are in close proximity or cross anadromous waters. Native allotment lands require following U. S. Bureau of Indian Affairs timber sale contracting process and approval.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peffley, R.E.
Developing an operator training program depends on each individual power plant's operating characteristics. This paper deals with the development of the existing, workable program used at the Eckert and Erickson Stations - Board of Water and Light, Lansing, Michigan. The Eckert Station is a coal fired complex consisting of 3 to 45 MW, 3 to 80 MW, and 4 process steam boilers. This training program encompasses seven (7) operating classifications administered by a Head Operator. A similar program is employed at a single unit 160 MW Erickson Station, covering three (3) operating classifications.
Modeling of the reburning process using sewage sludge-derived syngas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Werle, Sebastian, E-mail: sebastian.werle@polsl.pl
2012-04-15
Highlights: Black-Right-Pointing-Pointer Gasification provides an attractive method for sewage sludges treatment. Black-Right-Pointing-Pointer Gasification generates a fuel gas (syngas) which can be used as a reburning fuel. Black-Right-Pointing-Pointer Reburning potential of sewage sludge gasification gases was defined. Black-Right-Pointing-Pointer Numerical simulation of co-combustion of syngases in coal fired boiler has been done. Black-Right-Pointing-Pointer Calculation shows that analysed syngases can provide higher than 80% reduction of NO{sub x}. - Abstract: Gasification of sewage sludge can provide clean and effective reburning fuel for combustion applications. The motivation of this work was to define the reburning potential of the sewage sludge gasification gas (syngas). Amore » numerical simulation of the co-combustion process of syngas in a hard coal-fired boiler was done. All calculations were performed using the Chemkin programme and a plug-flow reactor model was used. The calculations were modelled using the GRI-Mech 2.11 mechanism. The highest conversions for nitric oxide (NO) were obtained at temperatures of approximately 1000-1200 K. The combustion of hard coal with sewage sludge-derived syngas reduces NO emissions. The highest reduction efficiency (>90%) was achieved when the molar flow ratio of the syngas was 15%. Calculations show that the analysed syngas can provide better results than advanced reburning (connected with ammonia injection), which is more complicated process.« less
Needs and perspectives of air quality improvement in Cracow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wertz, J.
1995-12-31
In 1970s and 80s the Cracow province area belonged to the regions of highest concentration of air pollutants throughout Europe. The majority of inhabitants, terrified of continuously worsening conditions of the environment, were of the opinion that this situation was caused by the industrial plants located within the Cracow area (town and/or province) as well as by the advection of pollutants from the neighboring Katowice province - the most industrialized region of Poland. The results of two large measurement series carried out in Cracow in 1984 and 1986 were surprising for the majority of the people. It appeared that 40%more » of the pollution came from local coal-fired boiler houses and household coal-fired stoves. These emission sources, situated at relatively low altitude above the ground level, were called low emission sources. The quantity of such sources has been estimated. It was estimated that the number of local boiler houses was close to 1,600 while the total number of household tile stoves reached 200,000. A full inventory of these sources drawn up in 1989-90 confirmed the quantity of existing boiler houses and the verified total number of tile stoves was 130,000. In 1986, the elimination of low emission sources was admitted to be one of the strategic directions of actions in the field of air quality protection. The following two solutions to this problem were accepted for implementation: (1) boiler house elimination by means of an administrative, compulsory decision, and (2) co-financing or even complete financing from the environmental protection fund, of the capital investment related to the elimination of a boiler house or its conversion to another mode of heating (gas, fuel-oil or connection to the municipal district heating loop). These two solutions are discussed.« less
NASA Astrophysics Data System (ADS)
Arkhipov, A. M.; Kanunnikov, A. A.; Kirichkov, V. S.; Prokhorov, V. B.; Fomenko, M. V.; Chernov, S. L.
2017-02-01
In reconstruction of operating pulverized coal-fired boilers, one of the main factors is the choice of a method for slag removal: dry bottom ash removal (DBAR) or slag-tap removal (STR). In this case, ecological and economic aspects should be taken into account, and also the early ignition of pulverized coal fuel, the reliability of operation of the furnace walls in the mode without slagging, and the stability of slag removal should be provided. In this work, issues of changeover of the pulverized coal-fired boilers of the TPP-210A type from the STR mode to the DBAR mode are considered. As of today, the main problems during the operation of these boilers are the high emissions of nitrogen oxides together with flue gases into the atmosphere and the appropriated payoffs, a small range of loads available, the necessity of stabilization of the pulverizedcoal flame sustainability by using the highly reactive fuel, large mechanical fuel underburning, etc. Results of studying aerodynamics of a furnace with DBAR obtained in the process of physical simulation are given; technical solutions and preliminary design (configuration of burners and nozzles in the boiler furnace, conceptual design of the pulverized coal burner, configuration of TPP-210A boiler with the low heat liberation of furnace cross-section and volumetric heat release) are set forth, which are associated with the optimization of aerodynamics of furnace volume, when the direct-flow burners and nozzles are used, and with organization of the efficient staged combustion of solid fuel. Two versions of possible modernization of a boiler unit are considered. Under conditions of the planned increase in the steam production capacity, the most promising measures are as follows: the DBAR implementation with reducing heat releases of the cross-section and volume of the furnace approximately by half, the installation of the direct-flow burners and nozzles with injection of recirculation gases into the active combustion zone by bleeding them from the turning chamber.
Numerical and Experimental Study on the Effect of Over Fire Air on NOx Distribution in Furnace
NASA Astrophysics Data System (ADS)
Wang, Qian; Deng, Yong-qiang; Xia, Yong-jun; Wu, Ying
2018-05-01
In this paper, a numerical investigation and experimental study was used to research the effect of a power plant 600MW supercritical four walls tangentially fired boiler furnace over fire air opening size on the inside furnace NOx concentration distribution and the results coincide. There are four cases in all. The influence and formation of NOx that was produced by pulverized coal furnace during combustion processes were analyzed. The research was proved that the over fire air has great effect on the concentration distribution of NOx in the furnance.
NASA Astrophysics Data System (ADS)
Komarov, I. I.; Rostova, D. M.; Vegera, A. N.
2017-11-01
This paper presents the results of study on determination of degree and nature of influence of operating conditions of burner units and flare geometric parameters on the heat transfer in a combustion chamber of the fire-tube boilers. Change in values of the outlet gas temperature, the radiant and convective specific heat flow rate with appropriate modification of an expansion angle and a flare length was determined using Ansys CFX software package. Difference between values of total heat flow and bulk temperature of gases at the flue tube outlet calculated using the known methods for thermal calculation and defined during the mathematical simulation was determined. Shortcomings of used calculation methods based on the results of a study conducted were identified and areas for their improvement were outlined.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, M.A.; Durfee, D.J.; Hughes, P.J.
1999-06-19
The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four, new, elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACUGHWB), water-cooled chiller with gas-fired hot water boiler (WCCYGHWB), or water-cooled chiller with gas-fired steam boiler (WCUGSB). Preventative maintenancemore » and capital renewal activities were not included in the available database. GHP schools reported average total costs at 2.13 cents/ft{sup 2}-yr, followed by ACC/GHWB schools at 2.88 cents/ft{sup 2}-yr, WCC/GSB schools at 3.73 cents/ft{sup 2}-yr, and WCC/GHWB schools at 6.07 cents/ft{sup 2}-yr. Because of tax-exemptions on material purchases, a reliance on in-house labor, and the absence of preventative maintenance records in the database, these costs are lower than those reported in previous studies. A strong relationship (R{sup 2}=O.52) was found between costs examined and cooling system age: the newer the cooling equipment, the less it costs to maintain.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martin, M.A.; Durfee, D.J.; Hughes, P.J.
1999-07-01
The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four new elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service, and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACC/GHWB), water-cooled chiller with gas-fired hot water boiler (WCC/GHWB), or water-cooled chiller with gas-fired steam boiler (WCC/GSB). Preventative maintenancemore » and capital renewal activities were not included in the available database. GHP schools reported average total costs at 2.13{cents}/ft{sup 2}-yr, followed by ACC/GHWB schools at 2.884{cents}/ft{sup 2}-yr, WCC/GSB schools at 3.73{cents}/ft{sup 2}-yr, and WCC/GHWB schools at 6.07{cents}/ft{sup 2}-yr. Because of tax exemptions on material purchases, a reliance on in-house labor, and the absence of preventative maintenance records in the database, these costs are lower than those reported in previous studies. A strong relationship (R{sup 2} = 0.52) was found between costs examined and cooling system age: the newer the cooling equipment, the less it costs to maintain.« less
Wang, Xi-fen; Zhou, Huai-chun
2005-01-01
The control of 3-D temperature distribution in a utility boiler furnace is essential for the safe, economic and clean operation of pc-fired furnace with multi-burner system. The development of the visualization of 3-D temperature distributions in pc-fired furnaces makes it possible for a new combustion control strategy directly with the furnace temperature as its goal to improve the control quality for the combustion processes. Studied in this paper is such a new strategy that the whole furnace is divided into several parts in the vertical direction, and the average temperature and its bias from the center in every cross section can be extracted from the visualization results of the 3-D temperature distributions. In the simulation stage, a computational fluid dynamics (CFD) code served to calculate the 3-D temperature distributions in a furnace, then a linear model was set up to relate the features of the temperature distributions with the input of the combustion processes, such as the flow rates of fuel and air fed into the furnaces through all the burners. The adaptive genetic algorithm was adopted to find the optimal combination of the whole input parameters which ensure to form an optimal 3-D temperature field in the furnace desired for the operation of boiler. Simulation results showed that the strategy could soon find the factors making the temperature distribution apart from the optimal state and give correct adjusting suggestions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hinton, W.S.; Maxwell, J.D.; Healy, E.C.
1997-12-31
This paper describes the completed Innovative Clean Coal Technology project which demonstrated SCR technology for reduction of flue gas NO{sub x} emissions from a utility boiler burning US high-sulfur coal. The project was sponsored by the US Department of Energy, managed and co-funded by Southern Company Services, Inc. on behalf of the Southern Company, and also co-funded by the Electric Power Research Institute and Ontario Hydro. The project was located at Gulf Power Company`s Plant Crist Unit 5 (a 75 MW tangentially-fired boiler burning US coals that had a sulfur content ranging from 2.5--2.9%), near Pensacola, Florida. The test programmore » was conducted for approximately two years to evaluate catalyst deactivation and other SCR operational effects. The SCR test facility had nine reactors: three 2.5 MW (5,000 scfm), and operated on low-dust flue gas. The reactors operated in parallel with commercially available SCR catalysts obtained from suppliers throughout the world. Long-term performance testing began in July 1993 and was completed in July 1995. A brief test facility description and the results of the project are presented in this paper.« less
NASA Astrophysics Data System (ADS)
Vainikka, P.; Silvennoinen, J.; Yrjas, P.; Frantsi, A.; Hietanen, L.; Hupa, M.; Taipale, R.
Aerosol and fly ash sampling was carried out at a 80MWth bubbling fluidised bed (BFB) boiler plant co-firing solid recovered fuel (SRF), spruce bark and paper mill wastewater sludge in two experimental conditions. The SRF-Bark ratio in the fuel mix was kept constant at 50%-50% on dry mass basis in both experiments but two sludge proportions were used: 15% and 4% on dry mass basis. Aerosol samples were collected from the superheater region of the boiler furnace and fly ash from the electrostatic precipitator (ESP). Na, K, Cl and S were found to be in mainly water soluble compounds in the aerosols sampled by means of a Dekati type Low Pressure Impactor (DLPI). Bromine was found in several weight percentages in aerosols and it was amongst the main elements in some of the samples collected. Bromine is assumed to mainly originate from flame retarded plastics and textiles in the SRF. According to the measurements, the fate of Br seems to be analogous to the other main halogen, Cl, and its conversion from fuel to aerosols was high, indicating a strong tendency to form bromine salts.
A fouling monitor alarm to prevent forced outages
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thompson, R.E.; Hickinbotham, A.; Fang, T.C.
2000-07-01
Many utilities rely on coal blending to meet emissions and boiler performance goals, but the increased variability in coal quality can adversely impact ash deposition and soot blowing requirements. Other utilities are experimenting with lower quality coals and burner zone blending of coals fired from different bunkers as part of a deregulation strategy to reduce fuel costs. However, these strategies can lead to slagging/fouling episodes, a possible outage, or a decrease in unit availability if boiler operations are not carefully monitored. This paper summarizes the development of software to monitor boiler fouling and to provide an advanced warning to themore » control operators when a fouling episode is imminent. With adequate warming, preemptive action can be taken (e.g., soot blowing, a change in coal blend, etc.) to potentially avoid a costly outage. The software utilizes a unique combination of combustion diagnostic techniques and convective section heat adsorption analyses to identify boiler operating conditions where ash deposition rates may be high and conductive to triggering a fouling episode. The paper outlines the history of the fouling problem and the implementation of the software on Wabamun Unit 4, a tangentially-fired unit with relatively narrow reheat tube spacing. The unit had a tendency to foul when burning a high alkaline (but low ash) coal seam. The paper discusses the software development, implementation, and data acquisitions activities. Preliminary test results are provided for Wabamun 4 and for Sundance Units 1 and 2 where the software was recently installed.« less
Reduction of Nitrogen Oxides Emissions from a Coal-Fired Boiler Unit
NASA Astrophysics Data System (ADS)
Zhuikov, Andrey V.; Feoktistov, Dmitry V.; Koshurnikova, Natalya N.; Zlenko, Lyudmila V.
2016-02-01
During combustion of fossil fuels a large amount of harmful substances are discharged into the atmospheres of cities by industrial heating boiler houses. The most harmful substances among them are nitrogen oxides. The paper presents one of the most effective technological solutions for suppressing nitrogen oxides; it is arrangement of circulation process with additional mounting of the nozzle directed into the bottom of the ash hopper. When brown high-moisture coals are burnt in the medium power boilers, generally fuel nitrogen oxides are produced. It is possible to reduce their production by two ways: lowering the temperature in the core of the torch or decreasing the excess-air factor in the boiler furnace. Proposed solution includes the arrangement of burning process with additional nozzle installed in the lower part of the ash hopper. Air supply from these nozzles creates vortex involving large unburned fuel particles in multiple circulations. Thereby time of their staying in the combustion zone is prolonging. The findings describe the results of the proposed solution; and recommendations for the use of this technological method are given for other boilers.
Combustion Of Poultry-Derived Fuel in a CFBC
NASA Astrophysics Data System (ADS)
Jia, Lufei; Anthony, Edward J.
Poultry farming generates large quantities of waste. Current disposal practice is to spread the poultry wastes onto farmland as fertilizer. However, as the factory farms for poultry grow both in numbers and size, the amount of poultry wastes generated has increased significandy in recent years. In consequence, excessive application of poultry wastes on farmland is resulting in more and more contaminants entering the surface water. One of the options being considered is the use of poultry waste as power plant fuel. Since poultry-derived fuel (PDF) is biomass, its co-firing will have the added advantage of reducing greenhouse gas emissions from power generation. To evaluate the combustion characteristics of co-firing PDF with coal, combustion tests of mixtures of coal and PDF were conducted in CanmetENERGY's pilot-scale CFBC. The goal of the tests was to verify that PDF can be co-fired with coal and, more importantly, that emissions from the combustion process are not adversely affected by the presence of PDF in the fuel feed. The test results were very promising and support the view that co-firing in an existing coal-fired CFBC is an effective method of utilizing this potential fuel, both resolving a potential waste disposal problem and reducing the amount of CO2 released by the boiler.
Modified precision-husky progrind H-3045 for chipping biomass
Dana Mitchell; Fernando Seixas; John Klepac
2008-01-01
A specific size of whole tree chip was needed to co-mill wood chips with coal. The specifications are stringent because chips must be mixed with coal, as opposed to a co-firing process. In co-firing, two raw products are conveyed separately to a boiler. In co-milling, such as at Alabama Power's Plant Gadsden, the chip and coal mix must pass through a series of...
Code of Federal Regulations, 2010 CFR
2010-07-01
... the boiler at a normal or conservatively high excess oxygen level in conjunction with these tests....2Substitute 1.25 times the highest NOX emission rate from the baseline correlation tests for the fuel (or fuel... potential NOX emission rate (MER) (as defined in § 72.2 of this chapter) for each unit operating hour...
Code of Federal Regulations, 2012 CFR
2012-07-01
... the boiler at a normal or conservatively high excess oxygen level in conjunction with these tests....2Substitute 1.25 times the highest NOX emission rate from the baseline correlation tests for the fuel (or fuel... potential NOX emission rate (MER) (as defined in § 72.2 of this chapter) for each unit operating hour...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1994-07-01
The Conference on Alternatives for Pollution Control from Coal-Fired Emission Sources presented cost-effective approaches for pollution control of low emission sources (LES). It also identified policies and strategies for implementation of pollution control measures at the local level. Plzen, Czech Republic, was chosen as the conference site to show participants first hand the LES problems facing Eastern Europe today. Collectively, these Proceedings contain clear reports on: (a) methods for evaluating the cost effectiveness of alternative approaches to control pollution from small coal-fired boilers and furnaces; (b) cost-effective technologies for controlling pollution from coal-fired boilers and furnaces; (c) case studies ofmore » assessment of cost effective pollution control measures for selected cities in eastern Europe; and (d) approaches for actually implementing pollution control measures in cities in Eastern Europe. It is intended that the eastern/central European reader will find in these Proceedings useful measures that can be applied to control emissions and clean the air in his city or region. The conference was sponsored by the United States Agency for International Development (AID), the United States Department of Energy (DOE), and the Czech Ministry of Industry and Trade. Selected papers have been indexed separately for inclusion in the Energy Science and Technology Database.« less
CRITERIA FOR SELECTION OF PCDD/F INDICATORS
Emission samples from a simulated hazardous waste-fired North American Package Boiler (NAPB) and a refuse-derived fuel incineration facility (RDFF) were analyzed separately and combined in order to identify single polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Becker, W.; Stalcup, T.; Schild, V.
1992-01-01
The Neil Simpson Unit is a 220,000 lb/hr pulverized coal boiler that was designed to fire a local Wyoming subbituminous coal. During the late 1980s, the Wyoming Department of Air Quality imposed emission limits on the Black Hills Power and Light Co., Neil Simpson Station. The new limits required Black Hills power to control not only particulate and sulfur dioxide (SO{sub 2}) emissions, but also nitrogen oxide (NO{sub x}) emissions. At the same time, Black Hills Power initiated an efficiency improvement study at Neil Simpson Station to investigate methods for reducing net electrical generation costs. This paper addresses the plantmore » efficiency and emissions studies, startup activities, the operating problems and successful operating solutions for NO{sub x} control when firing a Wyoming subbituminous coal. Also included is a summary of the post-0retrofit boiler performance data.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miles, T.R.; Miles, T.R. Jr.; Baxter, L.L.
1995-04-15
Alkali in the ash of annual crop biomass fuels creates serious fouling and slagging in conventional boilers. Even with the use of sorbents and other additives, power plants can only fire limited amounts of these fuels in combination with wood. The National Renewable Energy Laboratory (NREL), US Department of Energy, and the biomass power industry carried out eight full-scale firing tests and several laboratory experiments to study the nature and occurrence of deposits with the goal of increasing the quantities of these biofuels that can be used. This report describes the results of the laboratory and power plant tests thatmore » included: tracking and analyzing fuels and deposits by various methods; recording operating conditions; and extensive laboratory testing. The paper describes the occurrence of deposits, fuel and deposit analyses, boiler design and operation, fouling and slagging indicators, and recommendations. 37 refs., 41 figs., 17 tabs.« less
Low excess air burners keep boiler and air cleaner while cutting fuel costs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robinson, H.
1981-11-01
In the 1970s at the Humko Chemical Co., producers of fatty acids used in plastics, soaps, rubber products, and textiles, it was deemed necessary to modify existing boiler equipment to insure an adequate fuel supply and to increase efficienct. Existing equipment operated at an overall average efficiency of 77% and only 6% excess O/sub 2/ could be achieved with number 6 fuel oil and only 2.6% with natural gas. Cleaning the boilers and replacing existing burners with oil and gas firing units led to overall efficiency up to 84% with only 1% excess O/sub 2/. Even though fuel costs havemore » approximately tripled during the ensuing time, Humko's cost of producing steam has only doubled with the more efficienct equipment. (BLM)« less
Economic analysis of electric heating based on critical electricity price
NASA Astrophysics Data System (ADS)
Xie, Feng; Sun, Zhijie; Zhou, Xinnan; Fu, Chengran; Yang, Jie
2018-06-01
The State Grid Corporation of China proposes an alternative energy strategy, which will make electric heating an important task in the field of residential electricity consumption. This article takes this as the background, has made the detailed introduction to the inhabitant electric heating technology, and take the Zhangjiakou electric panels heating technology as an example, from the expense angle, has carried on the analysis to the electric panels heating economy. In the field of residential heating, electric panels operating costs less than gas boilers. After customers implying energy-saving behavior, electric panels operating cost is even lower than coal-fired boilers. The critical price is higher than the execution price, which indicates that the economic performance of the electric panels is significantly higher than that of the coal boiler.
Wang, Ruwei; Liu, Guijian; Zhang, Jiamei
2015-12-15
Coal-fired power plants (CFPPs) represent important source of atmospheric PAHs, however, their emission characterization are still largely unknown. In this work, the concentration, distribution and gas-particle partitioning of PM10- and gas-phase PAHs in flue gas emitted from different coal-fired utility boilers were investigated. Moreover, concentration and distribution in airborne PAHs from different functional areas of power plants were studied. People's inhalatory and dermal exposures to airborne PAHs at these sites were estimated and their resultant lung cancer and skin cancer risks were assessed. Results indicated that the boiler capacity and operation conditions have significant effect on PAH concentrations in both PM10 and gas phases due to the variation of combustion efficiency, whereas they take neglected effect on PAH distributions. The wet flue gas desulphurization (WFGD) takes significant effect on the scavenging of PAH in both PM10 and gas phases, higher scavenging efficiency were found for less volatile PAHs. PAH partitioning is dominated by absorption into organic matter and accompanied by adsorption onto PM10 surface. In addition, different partitioning mechanism is observed for individual PAHs, which is assumed arising from their chemical affinity and vapor pressure. Risk assessment indicates that both inhalation and dermal contact greatly contribute to the cancer risk for CFPP workers and nearby residents. People working in workshop are exposed to greater inhalation and dermal exposure risk than people living in nearby vicinity and working office. Copyright © 2015. Published by Elsevier B.V.
Kurihara, Miki; Ikeda, Koji; Izawa, Yoshinori; Deguchi, Yoshihiro; Tarui, Hitoshi
2003-10-20
A laser-induced breakdown spectroscopy (LIBS) technique has been applied for detection of unburned carbon in fly ash, and an automated LIBS unit has been developed and applied in a 1000-MW pulverized-coal-fired power plant for real-time measurement, specifically of unburned carbon in fly ash. Good agreement was found between measurement results from the LIBS method and those from the conventional method (Japanese Industrial Standard 8815), with a standard deviation of 0.27%. This result confirms that the measurement of unburned carbon in fly ash by use of LIBS is sufficiently accurate for boiler control. Measurements taken by this apparatus were also integrated into a boiler-control system with the objective of achieving optimal and stable combustion. By control of the rotating speed of a mill rotary separator relative to measured unburned-carbon content, it has been demonstrated that boiler control is possible in an optimized manner by use of the value of the unburned-carbon content of fly ash.
Multifuel industrial steam generation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mesko, J.E.
An inefficient, unreliable steam generation and distribution system at the Red River Army Depot (Texarkana, Tex.), a major industrial facility of the federal government, was replaced with a modern, multifuel-burning steam plant. In the new plant, steam is generated by three high-pressure field-erected boilers burning 100 percent coal, 100 percent refuse, or any combination of the two, while maintaining particulate emissions, SO{sub 2} concentration, and NO{sub x} and chlorine levels at or better than clean air standards. The plant, which has been in operation since 1986, is now part of the Army's Energy/Environment Showcase for demonstrating innovative technology to publicmore » and private operators. When the project began, the Red River depot faced several operational problems. Existing No. 2 oil- and gas- fired boilers in three separate boiler plants were inefficient, unreliable, and difficult to maintain. Extra boilers often had to be leased to provide for needed capacity. In addition, the facility had large quantities of waste to dispose of.« less
75 FR 45480 - Approval and Promulgation of Air Quality Implementation Plans; Minnesota
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-03
... consider your comment. Electronic files should avoid the use of special characters, any form of encryption... units at the facility are three fossil fuel- fired boilers (Nos. 1, 2, and 3), and four emergency...
46 CFR 52.25-7 - Electric boilers (modifies PEB-1 through PEB-19).
Code of Federal Regulations, 2011 CFR
2011-10-01
... ENGINEERING POWER BOILERS Other Boiler Types § 52.25-7 Electric boilers (modifies PEB-1 through PEB-19). Electric boilers required to comply with this part must meet the applicable provisions in this part and the... 46 Shipping 2 2011-10-01 2011-10-01 false Electric boilers (modifies PEB-1 through PEB-19). 52.25...
46 CFR 52.25-7 - Electric boilers (modifies PEB-1 through PEB-19).
Code of Federal Regulations, 2010 CFR
2010-10-01
... ENGINEERING POWER BOILERS Other Boiler Types § 52.25-7 Electric boilers (modifies PEB-1 through PEB-19). Electric boilers required to comply with this part must meet the applicable provisions in this part and the... 46 Shipping 2 2010-10-01 2010-10-01 false Electric boilers (modifies PEB-1 through PEB-19). 52.25...
46 CFR 52.25-7 - Electric boilers (modifies PEB-1 through PEB-19).
Code of Federal Regulations, 2012 CFR
2012-10-01
... ENGINEERING POWER BOILERS Other Boiler Types § 52.25-7 Electric boilers (modifies PEB-1 through PEB-19). Electric boilers required to comply with this part must meet the applicable provisions in this part and the... 46 Shipping 2 2012-10-01 2012-10-01 false Electric boilers (modifies PEB-1 through PEB-19). 52.25...
46 CFR 52.25-7 - Electric boilers (modifies PEB-1 through PEB-19).
Code of Federal Regulations, 2014 CFR
2014-10-01
... ENGINEERING POWER BOILERS Other Boiler Types § 52.25-7 Electric boilers (modifies PEB-1 through PEB-19). Electric boilers required to comply with this part must meet the applicable provisions in this part and the... 46 Shipping 2 2014-10-01 2014-10-01 false Electric boilers (modifies PEB-1 through PEB-19). 52.25...
46 CFR 52.25-7 - Electric boilers (modifies PEB-1 through PEB-19).
Code of Federal Regulations, 2013 CFR
2013-10-01
... ENGINEERING POWER BOILERS Other Boiler Types § 52.25-7 Electric boilers (modifies PEB-1 through PEB-19). Electric boilers required to comply with this part must meet the applicable provisions in this part and the... 46 Shipping 2 2013-10-01 2013-10-01 false Electric boilers (modifies PEB-1 through PEB-19). 52.25...
46 CFR 52.25-5 - Miniature boilers (modifies PMB-1 through PMB-21).
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false Miniature boilers (modifies PMB-1 through PMB-21). 52.25-5 Section 52.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-5 Miniature boilers (modifies PMB-1 through PMB-21). Miniature boilers must meet the applicable...
46 CFR 52.25-5 - Miniature boilers (modifies PMB-1 through PMB-21).
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false Miniature boilers (modifies PMB-1 through PMB-21). 52.25-5 Section 52.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-5 Miniature boilers (modifies PMB-1 through PMB-21). Miniature boilers must meet the applicable...
46 CFR 52.25-5 - Miniature boilers (modifies PMB-1 through PMB-21).
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 2 2011-10-01 2011-10-01 false Miniature boilers (modifies PMB-1 through PMB-21). 52.25-5 Section 52.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-5 Miniature boilers (modifies PMB-1 through PMB-21). Miniature boilers must meet the applicable...
46 CFR 52.25-5 - Miniature boilers (modifies PMB-1 through PMB-21).
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Miniature boilers (modifies PMB-1 through PMB-21). 52.25-5 Section 52.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-5 Miniature boilers (modifies PMB-1 through PMB-21). Miniature boilers must meet the applicable...
46 CFR 52.25-5 - Miniature boilers (modifies PMB-1 through PMB-21).
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 2 2013-10-01 2013-10-01 false Miniature boilers (modifies PMB-1 through PMB-21). 52.25-5 Section 52.25-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING POWER BOILERS Other Boiler Types § 52.25-5 Miniature boilers (modifies PMB-1 through PMB-21). Miniature boilers must meet the applicable...
Vacuum boilers developed heating surfaces technic and economic efficiency evaluation
NASA Astrophysics Data System (ADS)
Slobodina, E. N.; Mikhailov, A. G.; Semenov, B. A.
2018-01-01
The vacuum boilers as manufacturing proto types application analysis was carried out, the possible directions for the heating surfaces development are identified with a view to improving the energy efficiency. Economic characteristics to evaluate the vacuum boilers application efficiency (Net Discounted Income (NDI), Internal Rate of Return (IRR), Profitability Index (PI) and Payback Period) are represented. The given type boilers application technic and economic efficiency criteria were established. NDI changing curves depending on the finning coefficient and operating pressure were obtained as a result of the conducted calculation studies.
Metallurgical Analysis of Cracks Formed on Coal Fired Boiler Tube
NASA Astrophysics Data System (ADS)
Kishor, Rajat; Kyada, Tushal; Goyal, Rajesh K.; Kathayat, T. S.
2015-02-01
Metallurgical failure analysis was carried out for cracks observed on the outer surface of a boiler tube made of ASME SA 210 GR A1 grade steel. The cracks on the surface of the tube were observed after 6 months from the installation in service. A careful visual inspection, chemical analysis, hardness measurement, detailed microstructural analysis using optical and scanning electron microscopy coupled with energy dispersive X-ray spectroscopy were carried out to ascertain the cause for failure. Visual inspection of the failed tube revealed the presence of oxide scales and ash deposits on the surface of the tube exposed to fire. Many cracks extending longitudinally were observed on the surface of the tube. Bulging of the tube was also observed. The results of chemical analysis, hardness values and optical micrographs did not exhibit any abnormality at the region of failure. However, detailed SEM with EDS analysis confirmed the presence of various oxide scales. These scales initiated corrosion at both the inner and outer surfaces of the tube. In addition, excessive hoop stress also developed at the region of failure. It is concluded that the failure of the boiler tube took place owing to the combined effect of the corrosion caused by the oxide scales as well as the excessive hoop stress.
Kuang, Min; Li, Zhengqi; Xu, Shantian; Zhu, Qunyi
2011-04-15
Within a Mitsui Babcock Energy Limited down-fired pulverized-coal 350 MW(e) utility boiler, in situ experiments were performed, with measurements taken of gas temperatures in the burner and near the right-wall regions, and of gas concentrations (O(2) and NO) from the near-wall region. Large combustion differences between zones near the front and rear walls and particularly high NO(x) emissions were found in the boiler. With focus on minimizing these problems, a new technology based on multiple-injection and multiple-staging has been developed. Combustion improvements and NO(x) reductions were validated by investigating three aspects. First, numerical simulations of the pulverized-coal combustion process and NO(x) emissions were compared in both the original and new technologies. Good agreement was found between simulations and in situ measurements with the original technology. Second, with the new technology, gas temperature and concentration distributions were found to be symmetric near the front and rear walls. A relatively low-temperature and high-oxygen-concentration zone formed in the near-wall region that helps mitigate slagging in the lower furnace. Third, NO(x) emissions were found to have decreased by as much as 50%, yielding a slight decrease in the levels of unburnt carbon in the fly ash.
Some infra-red applications in combustion technology. Interim report 1 March-31 August 78
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swithenbank, J.; Turan, A.; Taylor, D.S.
1978-01-01
Infrared technology finds many applications in the field of combustion ranging from pollution monitoring, through military systems, to the control of industrial furnaces and boilers. This review of some selected concepts highlights the interaction between the diagnostic role of infrared measurements and the current status of mathematical modelling of combustion systems. The link between measurement and and computing has also evolved to the point where a digital processor is becoming an inherent part of many new instruments. This point is illustrated by reference to the diffraction particle size meter, fire detection and alarm systems, and furnace control. In the future,more » as fuels become scarce and expensive, and micro-electronics become more available and inexpensive, it is certain that infrared devices will find increasing application in smaller industries and the home. (Author)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
K. Payette; D. Tillman
During the period October 1, 2000 - December 31, 2000, Allegheny Energy Supply Co., LLC (Allegheny) executed a Cooperative Agreement with the National Energy Technology Laboratory to implement a major cofiring demonstration at the Willow Island Generating Station Boiler No.2. Willow Island Boiler No.2 is a cyclone boiler. Allegheny also will demonstrate separate injection cofiring at the Albright Generating Station Boiler No.3, a tangentially fired boiler. The Allegheny team includes Foster Wheeler as its primary subcontractor. Additional subcontractors are Cofiring Alternatives and N.S. Harding and Associates. This report summarizes the activities associated with the Designer Opportunity Fuel program, and demonstrationsmore » at Willow Island and Albright Generating Stations. The second quarter of the project involved completing the designs for each location. Further, geotechnical investigations proceeded at each site. Preparations were made to perform demolition on two small buildings at the Willow Island site. Fuels strategies were initiated for each site. Test planning commenced for each site. A groundbreaking ceremony was held at the Willow Island site on October 18, with Governor C. Underwood being the featured speaker.« less
Case Study for the ARRA-Funded Ground Source Heat Pump Demonstration at Ball State University
DOE Office of Scientific and Technical Information (OSTI.GOV)
Im, Piljae; Liu, Xiaobing; Henderson, Jr., Hugh
With funding provided by the American Recovery and Reinvestment Act (ARRA), 26 ground-source heat pump (GSHP) projects were competitively selected in 2009 to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. One of the selected demonstration projects is a district central GSHP system installed at Ball State University (BSU) in Muncie, IN. Prior to implementing the district GSHP system, 47 major buildings in BSU were served by a central steam plant with four coal-fired and three natural-gas-fired steam boilers. Cooling was provided by five water-cooled centrifugal chillers at the District Energy Station Southmore » (DESS). The new district GSHP system replaced the existing coal-fired steam boilers and conventional water-cooled chillers. It uses ground-coupled heat recovery (HR) chillers to meet the simultaneous heating and cooling demands of the campus. The actual performance of the GSHP system was analyzed based on available measured data from August 2015 through July 2016, construction drawings, maintenance records, personal communications, and construction costs. Since Phase 1 was funded in part by the ARRA grant, it is the focus of this case study. The annual energy consumption of the GSHP system was calculated based on the available measured data and other related information. It was compared with the performance of a baseline scenario— a conventional water-cooled chiller and natural-gas-fired boiler system, both of which meet the minimum energy efficiencies allowed by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE 90.1-2013). The comparison was made to determine source energy savings, energy cost savings, and CO2 emission reductions achieved by the GSHP system. A cost analysis was performed to evaluate the simple payback of the GSHP system. The following sections summarize the results of the analysis, the lessons learned, and recommendations for improvement in the operation of this district GSHP system.« less
46 CFR 52.01-50 - Fusible plugs (modifies A-19 through A-21).
Code of Federal Regulations, 2013 CFR
2013-10-01
... (30 psig), if fired with solid fuel not in suspension, or if not equipped for unattended waterbed... back Scotch boilers, 2 inches above the top row of tubes. (j) [Reserved] (k)(1) Fusible plugs shall be...
Direct firing of coal for power production
NASA Technical Reports Server (NTRS)
Papay, L. T.
1978-01-01
The use of new technology and advanced emission control hardware to reduce emissions from the direct combustion of coal to produce electricity in California is considered. The technical feasibilty of a demonstration project on an existing 81-MW boiler is demonstrated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rode, J.R.; Brzezeina, P.; Strach, F.
This paper discusses the engineering considerations related to the design of a new 110 MWe atmospheric fluidized bed boiler (CFB) and boiler island auxiliaries for installation at the CEZ, a.s. (Czech Republic Utility) Ledvice Power Station. The plant is located in the northwest Bohemia area of the Czech Republic in the foothills of the Krusne Hory Mountains, between the towns of Bilina and Teplice. The type of fuel to be burned in the CFB is brown coal which requires unique design considerations in as well as the particular boiler operational parameters. The impetus behind the addition of this new CFBmore » at the plant is that the existing pulverized coal fired steam generator which was put in service in 1969 is unable to meet new regulations and laws regarding compliance with the protection of the environment and will be replaced once the new CFB unit is brought into service. A technical-economic study conducted by CEZ, a.s. evaluated CFB technology as the most advantageous from a long-term standpoint. The following variations were considered in the study: boiler retrofit and construction of new ash handling equipment; implementation of the combined cycle based upon natural gas; and reconstruction of the boiler equipment with transition to atmospheric fluid-bed combustion. The selection of the supplier of fluid-bed boiler was performed with an emphasis of the bidders` references as for the construction and operation of fluid-bed boilers with the outputs of min. 300 t/hr.« less
Thermal gain of CHP steam generator plants and heat supply systems
NASA Astrophysics Data System (ADS)
Ziganshina, S. K.; Kudinov, A. A.
2016-08-01
Heating calculation of the surface condensate heat recovery unit (HRU) installed behind the BKZ-420-140 NGM boiler resulting in determination of HRU heat output according to fire gas value parameters at the heat recovery unit inlet and its outlet, heated water quantity, combustion efficiency per boiler as a result of installation of HRU, and steam condensate discharge from combustion products at its cooling below condensing point and HRU heat exchange area has been performed. Inspection results of Samara CHP BKZ-420-140 NGM power boilers and field tests of the surface condensate heat recovery unit (HRU) made on the bimetal calorifier base KCk-4-11 (KSk-4-11) installed behind station no. 2 Ulyanovsk CHP-3 DE-10-14 GM boiler were the basis of calculation. Integration of the surface condensation heat recovery unit behind a steam boiler rendered it possible to increase combustion efficiency and simultaneously decrease nitrogen oxide content in exit gases. Influence of the blowing air moisture content, the excess-air coefficient in exit gases, and exit gases temperature at the HRU outlet on steam condensate amount discharge from combustion products at its cooling below condensing point has been analyzed. The steam condensate from HRU gases is offered as heat system make-up water after degasification. The cost-effectiveness analysis of HRU installation behind the Samara CHP BKZ-420-140 NGM steam boiler with consideration of heat energy and chemically purified water economy has been performed. Calculation data for boilers with different heat output has been generalized.
Statistical modeling of an integrated boiler for coal fired thermal power plant.
Chandrasekharan, Sreepradha; Panda, Rames Chandra; Swaminathan, Bhuvaneswari Natrajan
2017-06-01
The coal fired thermal power plants plays major role in the power production in the world as they are available in abundance. Many of the existing power plants are based on the subcritical technology which can produce power with the efficiency of around 33%. But the newer plants are built on either supercritical or ultra-supercritical technology whose efficiency can be up to 50%. Main objective of the work is to enhance the efficiency of the existing subcritical power plants to compensate for the increasing demand. For achieving the objective, the statistical modeling of the boiler units such as economizer, drum and the superheater are initially carried out. The effectiveness of the developed models is tested using analysis methods like R 2 analysis and ANOVA (Analysis of Variance). The dependability of the process variable (temperature) on different manipulated variables is analyzed in the paper. Validations of the model are provided with their error analysis. Response surface methodology (RSM) supported by DOE (design of experiments) are implemented to optimize the operating parameters. Individual models along with the integrated model are used to study and design the predictive control of the coal-fired thermal power plant.
Low NOx combustion and SCR flow field optimization in a low volatile coal fired boiler.
Liu, Xing; Tan, Houzhang; Wang, Yibin; Yang, Fuxin; Mikulčić, Hrvoje; Vujanović, Milan; Duić, Neven
2018-08-15
Low NO x burner redesign and deep air staging have been carried out to optimize the poor ignition and reduce the NO x emissions in a low volatile coal fired 330 MW e boiler. Residual swirling flow in the tangentially-fired furnace caused flue gas velocity deviations at furnace exit, leading to flow field unevenness in the SCR (selective catalytic reduction) system and poor denitrification efficiency. Numerical simulations on the velocity field in the SCR system were carried out to determine the optimal flow deflector arrangement to improve flow field uniformity of SCR system. Full-scale experiment was performed to investigate the effect of low NO x combustion and SCR flow field optimization. Compared with the results before the optimization, the NO x emissions at furnace exit decreased from 550 to 650 mg/Nm³ to 330-430 mg/Nm³. The sample standard deviation of the NO x emissions at the outlet section of SCR decreased from 34.8 mg/Nm³ to 7.8 mg/Nm³. The consumption of liquid ammonia reduced from 150 to 200 kg/h to 100-150 kg/h after optimization. Copyright © 2018. Published by Elsevier Ltd.
46 CFR 63.01-3 - Scope and applicability.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING AUTOMATIC AUXILIARY... automatic auxiliary boilers, automatic heating boilers, automatic waste heat boilers, donkey boilers... control systems) used for the generation of steam and/or oxidation of ordinary waste materials and garbage...
46 CFR 63.01-3 - Scope and applicability.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING AUTOMATIC AUXILIARY... automatic auxiliary boilers, automatic heating boilers, automatic waste heat boilers, donkey boilers... control systems) used for the generation of steam and/or oxidation of ordinary waste materials and garbage...
Superheater Corrosion In Biomass Boilers: Today's Science and Technology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sharp, William
2011-12-01
This report broadens a previous review of published literature on corrosion of recovery boiler superheater tube materials to consider the performance of candidate materials at temperatures near the deposit melting temperature in advanced boilers firing coal, wood-based fuels, and waste materials as well as in gas turbine environments. Discussions of corrosion mechanisms focus on the reactions in fly ash deposits and combustion gases that can give corrosive materials access to the surface of a superheater tube. Setting the steam temperature of a biomass boiler is a compromise between wasting fuel energy, risking pluggage that will shut the unit down, andmore » creating conditions that will cause rapid corrosion on the superheater tubes and replacement expenses. The most important corrosive species in biomass superheater corrosion are chlorine compounds and the most corrosion resistant alloys are typically FeCrNi alloys containing 20-28% Cr. Although most of these materials contain many other additional additions, there is no coherent theory of the alloying required to resist the combination of high temperature salt deposits and flue gases that are found in biomass boiler superheaters that may cause degradation of superheater tubes. After depletion of chromium by chromate formation or chromic acid volatilization exceeds a critical amount, the protective scale gives way to a thick layer of Fe{sub 2}O{sub 3} over an unprotective (FeCrNi){sub 3}O{sub 4} spinel. This oxide is not protective and can be penetrated by chlorine species that cause further acceleration of the corrosion rate by a mechanism called active oxidation. Active oxidation, cited as the cause of most biomass superheater corrosion under chloride ash deposits, does not occur in the absence of these alkali salts when the chloride is present as HCl gas. Although a deposit is more corrosive at temperatures where it is molten than at temperatures where it is frozen, increasing superheater tube temperatures through the measured first melting point of fly ash deposits does not necessarily produce a step increase in corrosion rate. Corrosion rate typically accelerates at temperatures below the first melting temperature and mixed deposits may have a broad melting temperature range. Although the environment at a superheater tube surface is initially that of the ash deposits, this chemistry typically changes as the deposits mature. The corrosion rate is controlled by the environment and temperature at the tube surface, which can only be measured indirectly. Some results are counter-intuitive. Two boiler manufacturers and a consortium have developed models to predict fouling and corrosion in biomass boilers in order to specify tube materials for particular operating conditions. It would be very useful to compare the predictions of these models regarding corrosion rates and recommended alloys in the boiler environments where field tests will be performed in the current program. Manufacturers of biomass boilers have concluded that it is more cost-effective to restrict steam temperatures, to co-fire biofuels with high sulfur fuels and/or to use fuel additives rather than try to increase fuel efficiency by operating with superheater tube temperatures above melting temperature of fly ash deposits. Similar strategies have been developed for coal fired and waste-fired boilers. Additives are primarily used to replace alkali metal chloride deposits with higher melting temperature and less corrosive alkali metal sulfate or alkali aluminum silicate deposits. Design modifications that have been shown to control superheater corrosion include adding a radiant pass (empty chamber) between the furnace and the superheater, installing cool tubes immediately upstream of the superheater to trap high chloride deposits, designing superheater banks for quick replacement, using an external superheater that burns a less corrosive biomass fuel, moving circulating fluidized bed (CFB) superheaters from the convective pass into the hot recirculated fluidizing medium and adding an insulating layer to superheater tubes to raise their surface temperature above the dew point temperature of alkali chlorides. These design changes offer advantages but introduce other challenges. For example, operating with superheater temperatures above the dew point of alkali chlorides could require the use of creep-resistant tube alloys and doesn't eliminate chloride corrosion. Improved test methods that can be applied within this project include automated dimensional metrology to make a statistical analysis of depth of penetration and corrosion product thickness, and simultaneous thermal analysis measurements to quantify the melting of complex ashes and avoid the unreliability of the standard ash fusion test. Other important developments in testing include the installation of individually-temperature-controlled superheater loops for corrosion testing in operating boilers and temperature gradient testing.« less
8. RW Meyer Sugar Mill: 18761889. Simple, singlecylinder, horizontal, reciprocating ...
8. RW Meyer Sugar Mill: 1876-1889. Simple, single-cylinder, horizontal, reciprocating steam engine, model No. 1, 5' x 10', 6 hp, 175 rpm. Manufactured by Ames Iron Works, Oswego, New York, 1879. View: Steam engine powered the mill's centrifugals. It received steam from the locomotive type, fire-tube portable boiler in the background. The engine's water pump which pumped water from the feed-water clarifying cistern, in between the boiler and engine, through a pre-heat system and on to the boiler, is seen in front of the fluted cylinder. The fly-ball governor, missing its balls, the steam port, and manual throttle valve are above and behind the cylinder. The flywheel, drive shaft, and pulley are on the left side of the engine bed. - R. W. Meyer Sugar Mill, State Route 47, Kualapuu, Maui County, HI
NASA Astrophysics Data System (ADS)
Grzeszczak, Jan; Grela, Łukasz; Achter, Thomas
2017-12-01
The paper covers problems of the owners of a fleet of long-operated conventional power plants that are going to be decommissioned soon in result of failing to achieve new admissible emissions levels or exceeding pressure elements design lifetime. Energoprojekt-Katowice SA, Siemens AG and Rafako SA presents their joint concept of the solution which is a 2on1 concept - replacing two unit by two ultra-supercritical boilers feeding one turbine. Polish market has been taken as an example.
1988-12-01
a flue gas grab sample for orsat analysis (measures oxygen, and carbon dioxide for stack gas molecular weight determination and emissions correction... molecular weight, was obtained during particulate sampling. Testing was initially started on boiler 2 at the maximum rated steam output of 120,000 lbs/hr...I, r*~td AN[D l FL B( R\\ ViQ( lPjN L!II(,t 1 (d) Open burning of put.rcible iear- i\\ % ~i~ emisions , ec.dirig c dn jc p. c ,f1 pre- cri :rig pair
Assessment of industrial applications for fuel cell cogeneration systems
NASA Technical Reports Server (NTRS)
Stickles, R. P.; Oneill, J. K.; Smith, E. H.
1978-01-01
The fuel cell energy systems are designed with and without a utility connection for emergency back-up power. Sale of electricity to the utility during periods of low plant demand is not considered. For each of the three industrial applications, conceptual designs were also developed for conventional utility systems relying on purchased electric power and fossil-fired boilers for steam/hot water. The capital investment for each energy system is estimated. Annual operating costs are also determined for each system. These cost estimates are converted to levelized annual costs by applying appropriate economic factors. The breakeven electricity price that would make fuel cell systems competitive with the conventional systems is plotted as a function of naphtha price. The sensitivity of the breakeven point to capital investment and coal price is also evaluated.
10 CFR 431.110 - Energy conservation standards and their effective dates.
Code of Federal Regulations, 2011 CFR
2011-01-01
... heaters ≤155,000 Btu/hr>155,000 Btu/hr 80%80% Q/800 + 110(Vr) 1/2 (Btu/hr)Q/800 + 110(Vr) 1/2 (Btu/hr) Oil-fired storage water heaters ≤155,000 Btu/hr>155,000 Btu/hr 78%78% Q/800 + 110(Vr) 1/2 (Btu/hr)Q/800 + 110(Vr) 1/2 (Btu/hr) Gas-fired instantaneous water heaters and hot water supply boilers <10 gal≥10 gal...
10 CFR 431.110 - Energy conservation standards and their effective dates.
Code of Federal Regulations, 2010 CFR
2010-01-01
... heaters ≤155,000 Btu/hr>155,000 Btu/hr 80%80% Q/800 + 110(Vr) 1/2 (Btu/hr)Q/800 + 110(Vr) 1/2 (Btu/hr) Oil-fired storage water heaters ≤155,000 Btu/hr>155,000 Btu/hr 78%78% Q/800 + 110(Vr) 1/2 (Btu/hr)Q/800 + 110(Vr) 1/2 (Btu/hr) Gas-fired instantaneous water heaters and hot water supply boilers <10 gal≥10 gal...
Smithville Lake Historical Resources Mitigation Program: Oral History.
1980-02-01
of goods, Galoshes, cap.,, and overalls, Candies, cookies , and breakfast foods, Muslin, matches, and calico, and mittens, Buckets, pans and pails...i - .i If you never traded at my father’s store. You missed a lot, you see. You could even order a hand-out lunch Of soda pop, cookies ...back there. They had a little engine that ran their dough mixing machine and one thing or another. They fired up the boiler on Thursdays, and we fired
Chen, Bingyu; Liu, Guijian; Sun, Ruoyu
2016-05-01
A better understanding on the partitioning behavior of mercury (Hg) during coal combustion in large-scale coal-fired power plants is fundamental for drafting Hg-emission control regulations. Two large coal-fired utility boilers, equipped with electrostatic precipitators (ESPs) and a wet flue gas desulfurization (WFGD) system, respectively, in coal energy-dominant Huainan City, China, were selected to investigate the distribution and fate of Hg during coal combustion. In three sampling campaigns, we found that Hg in bottom ash was severely depleted with a relative enrichment (RE) index <7 %, whereas the RE index for fly ash (9-54%) was comparatively higher and variable. Extremely high Hg was concentrated in gypsum (≤4500 ng/g), which is produced in the WFGD system. Mass balance calculation shows that the shares of Hg in bottom ash, fly ash, WFGD products (gypsum, effluents, sludge), and stack emissions were <2, 17-32, 7-22, and 54-82%, respectively. The Hg-removal efficiencies of ESPs, WFGD, and ESPs + WFGD were 17-32, 10-29, and 36-46%, respectively. The Hg-emission factor of studied boilers was in a high range of 0.24-0.29 g Hg/t coal. We estimated that Hg emissions in all Huainan coal-fired power plants varied from 1.8 Mg in 2003 to 7.3 Mg in 2010.
40 CFR 266.110 - Waiver of DRE trial burn for boilers.
Code of Federal Regulations, 2014 CFR
2014-07-01
... percent of fuel fired to the device shall be fossil fuel, fuels derived from fossil fuel, tall oil, or, if... comparable to fossil fuel. Such fuels are termed “primary fuel” for purposes of this section. (Tall oil is a...
40 CFR 266.110 - Waiver of DRE trial burn for boilers.
Code of Federal Regulations, 2010 CFR
2010-07-01
... percent of fuel fired to the device shall be fossil fuel, fuels derived from fossil fuel, tall oil, or, if... comparable to fossil fuel. Such fuels are termed “primary fuel” for purposes of this section. (Tall oil is a...