Sample records for fires warning shot

  1. 32 CFR 632.5 - Use of firearms.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... not fire if shots are likely to harm innocent bystanders. (3) Since warning shots could harm innocent bystanders, avoid firing them. However, when lesser degrees of force have failed, the law enforcement or.... If able to avoid hazards to innocent persons in these cases, fire warning shots. (4) Aim to disable...

  2. Cases of death caused by gas or warning firearms.

    PubMed

    Rothschild, M A; Maxeiner, H; Schneider, V

    1994-01-01

    Five cases of lethal injuries caused by gas or warning firearms are discussed. In one suicide case a modified weapon (elongated barrel) and steel bullets were used to fire a shot into the head, the bullets lodged in the skull and lethal bleeding resulted. In the other cases conventional gas weapons without evidence of alteration were used for contact shots; injuries were caused by the effect of propelling powder gases. Two of these cases were suicides (temporal contact shot and back of the neck contact shot), one was an accident (inguinal contact shot with lethal bleeding), and one was an attack by another person with a contact shot against the neck with bilateral tears of the hypopharynx. After successful surgery, a delayed death occurred 12 days later caused by bleeding into the airways from the ruptured external carotid artery.

  3. U. S. Naval Forces, Vietnam Monthly Historical Summary for December 1966

    DTIC Science & Technology

    1967-02-15

    the northwest tip of Cu Lao May, three and one half miles southeast of Can Tho. The sampan Ignored halls and warning shots and continued to evade...machine gun. The patrol cleared the area to the southeast , returning fire as it withdrew. PBRs 86 and 97 joined the engagement and came under fire from...the south bank» ine four PBRs then stood by to the southeast of the kill zone as the Cang Long sub-sector artillery battery fired eight rounds of

  4. NATO: Revisiting American Commitment

    DTIC Science & Technology

    2013-03-01

    ineffective with “ virtually no prospect that their soldiers would fire a shot in anger.”10 This situation in turn reduces the overall morale of the force...NATO countries would not go on record to express their concern.32 The arms sales by “Old Europe” to Russia suggest a type of myopia in their view...in capabilities” that might possibly result in a “collective military irrelevance.” Finally, Secretary Gates warned, The blunt reality is that there

  5. A systematic examination of the bone destruction pattern of the two-shot technique

    PubMed Central

    Stoetzer, Marcus; Stoetzer, Carsten; Rana, Majeed; Zeller, Alexander; Hanke, Alexander; Gellrich, Nils-Claudius; von See, Constantin

    2014-01-01

    Introduction: The two-shot technique is an effective stopping power method. The precise mechanisms of action on the bone and soft-tissue structures of the skull; however, remain largely unclear. The aim of this study is to compare the terminal ballistics of the two-shot and single-shot techniques. Materials and Methods: 40 fresh pigs’ heads were randomly divided into 4 groups (n = 10). Either a single shot or two shots were fired at each head with a full metal jacket or a semi-jacketed bullet. Using thin-layer computed tomography and photography, the diameter of the destruction pattern and the fractures along the bullet path were then imaged and assessed. Results: A single shot fired with a full metal jacket bullet causes minor lateral destruction along the bullet path. With two shots fired with a full metal jacket bullet, however, the maximum diameter of the bullet path is significantly greater (P < 0.05) than it is with a single shot fired with a full metal jacket bullet. In contrast, the maximum diameter with a semi-jacketed bullet is similar with the single-shot and two-shot techniques. Conclusion: With the two-shot technique, a full metal jacket bullet causes a destruction pattern that is comparable to that of a single shot fired with a semi-jacketed bullet. PMID:24812454

  6. 30 CFR 75.1103-5 - Automatic fire warning devices; actions and response.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Automatic fire warning devices; actions and... Protection § 75.1103-5 Automatic fire warning devices; actions and response. (a) When the carbon monoxide... fire sensor and warning device systems shall provide an effective warning signal at the following...

  7. 30 CFR 75.1103-5 - Automatic fire warning devices; actions and response.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Automatic fire warning devices; actions and... Protection § 75.1103-5 Automatic fire warning devices; actions and response. (a) When the carbon monoxide... fire sensor and warning device systems shall provide an effective warning signal at the following...

  8. 30 CFR 75.1103-3 - Automatic fire sensor and warning device systems; minimum requirements; general.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-3 Automatic fire sensor and warning device systems; minimum requirements; general. Automatic fire sensor and warning device systems installed in belt haulageways of...

  9. 30 CFR 75.1103-3 - Automatic fire sensor and warning device systems; minimum requirements; general.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-3 Automatic fire sensor and warning device systems; minimum requirements; general. Automatic fire sensor and warning device systems installed in belt haulageways of...

  10. 30 CFR 75.1103-3 - Automatic fire sensor and warning device systems; minimum requirements; general.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-3 Automatic fire sensor and warning device systems; minimum requirements; general. Automatic fire sensor and warning device systems installed in belt haulageways of...

  11. 30 CFR 75.1103-3 - Automatic fire sensor and warning device systems; minimum requirements; general.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-3 Automatic fire sensor and warning device systems; minimum requirements; general. Automatic fire sensor and warning device systems installed in belt haulageways of...

  12. 30 CFR 75.1103-4 - Automatic fire sensor and warning device systems; installation; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-4 Automatic fire sensor and warning device systems; installation; minimum requirements. (a) Effective December 31, 2009, automatic fire sensor and warning device...

  13. 30 CFR 75.1103-4 - Automatic fire sensor and warning device systems; installation; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-4 Automatic fire sensor and warning device systems; installation; minimum requirements. (a) Effective December 31, 2009, automatic fire sensor and warning device...

  14. Protect Your Baby from Bleeds: Talk to Your Healthcare Provider about Vitamin K

    MedlinePlus

    ... a shot into a muscle in the leg. One shot given after birth will protect your baby from ... warning signs of VKDB? In the majority of cases of VKDB, there are NO WARN- ING SIGNS at all before a ... Vitamin K safe? A study from the early 1990’s found a possible link ...

  15. Rules of Engagement for Land Forces: A Matter of Training, not Lawyering

    DTIC Science & Technology

    1994-04-01

    display that you have superior force at your disposal. Warning shot. Shoot a warning shot, if authorized. Pepper spray. Spray cayenne pepper spray, if...to indicate available force. He may use pepper spray or some other irritant, * C-7 if available, to ward off those who may reach toward a vehicle. He

  16. 30 CFR 75.1103-8 - Automatic fire sensor and warning device systems; examination and test requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-8 Automatic fire sensor and warning device systems; examination and test requirements. (a) Automatic fire sensor and warning device systems shall be examined at...

  17. 30 CFR 75.1103-8 - Automatic fire sensor and warning device systems; examination and test requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-8 Automatic fire sensor and warning device systems; examination and test requirements. (a) Automatic fire sensor and warning device systems shall be examined at...

  18. 30 CFR 75.1103-8 - Automatic fire sensor and warning device systems; examination and test requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-8 Automatic fire sensor and warning device systems; examination and test requirements. (a) Automatic fire sensor and warning device systems shall be examined at...

  19. 30 CFR 75.1103-8 - Automatic fire sensor and warning device systems; examination and test requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-8 Automatic fire sensor and warning device systems; examination and test requirements. (a) Automatic fire sensor and warning device systems shall be examined at...

  20. 30 CFR 75.1103-8 - Automatic fire sensor and warning device systems; examination and test requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Automatic fire sensor and warning device...-UNDERGROUND COAL MINES Fire Protection § 75.1103-8 Automatic fire sensor and warning device systems; examination and test requirements. (a) Automatic fire sensor and warning device systems shall be examined at...

  1. 14 CFR 91.1415 - CAMP: Mechanical reliability reports.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... failure, malfunction, or defect in an aircraft concerning— (1) Fires during flight and whether the related fire-warning system functioned properly; (2) Fires during flight not protected by related fire-warning system; (3) False fire-warning during flight; (4) An exhaust system that causes damage during flight to...

  2. 14 CFR 91.1415 - CAMP: Mechanical reliability reports.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... failure, malfunction, or defect in an aircraft concerning— (1) Fires during flight and whether the related fire-warning system functioned properly; (2) Fires during flight not protected by related fire-warning system; (3) False fire-warning during flight; (4) An exhaust system that causes damage during flight to...

  3. 10 CFR Appendix H to Part 73 - Weapons Qualification Criteria

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... position Shotgun 1 1 7 yards 2 Double 0 buck-shot 4 seconds At low ready position fire 2 rounds standing Minimum qualifying = 70%. 2 12 15 yards 4 Double 0 buck-shot 15 seconds At low ready position fire 2 rounds standing, reload and fire 2 rounds 3 12 25 yards 4 rifled slugs or 00 buck-shot 20 seconds On...

  4. 10 CFR Appendix H to Part 73 - Weapons Qualification Criteria

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... position Shotgun 1 1 7 yards 2 Double 0 buck-shot 4 seconds At low ready position fire 2 rounds standing Minimum qualifying = 70%. 2 12 15 yards 4 Double 0 buck-shot 15 seconds At low ready position fire 2 rounds standing, reload and fire 2 rounds 3 12 25 yards 4 rifled slugs or 00 buck-shot 20 seconds On...

  5. 10 CFR Appendix H to Part 73 - Weapons Qualification Criteria

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... position Shotgun 1 1 7 yards 2 Double 0 buck-shot 4 seconds At low ready position fire 2 rounds standing Minimum qualifying = 70%. 2 12 15 yards 4 Double 0 buck-shot 15 seconds At low ready position fire 2 rounds standing, reload and fire 2 rounds 3 12 25 yards 4 rifled slugs or 00 buck-shot 20 seconds On...

  6. 10 CFR Appendix H to Part 73 - Weapons Qualification Criteria

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... position Shotgun 1 1 7 yards 2 Double 0 buck-shot 4 seconds At low ready position fire 2 rounds standing Minimum qualifying = 70%. 2 12 15 yards 4 Double 0 buck-shot 15 seconds At low ready position fire 2 rounds standing, reload and fire 2 rounds 3 12 25 yards 4 rifled slugs or 00 buck-shot 20 seconds On...

  7. 10 CFR Appendix H to Part 73 - Weapons Qualification Criteria

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... position Shotgun 1 1 7 yards 2 Double 0 buck-shot 4 seconds At low ready position fire 2 rounds standing Minimum qualifying = 70%. 2 12 15 yards 4 Double 0 buck-shot 15 seconds At low ready position fire 2 rounds standing, reload and fire 2 rounds 3 12 25 yards 4 rifled slugs or 00 buck-shot 20 seconds On...

  8. [Injuries and fatalities caused by gas-/warning weapons].

    PubMed

    Maxeiner, H; Schneider, V

    1989-01-01

    Detailed report of 5 cases of violation with gas or warning firearms, 3 of them lethal. In one case a modified weapon (elongated barrel) and steel bullets were used, resulting in shot of the head with retained missile and lethal bleeding. In the other cases, regular weapons (8 or 9 mm cartridges) were used for contact shots; violation occurred only by the effect of powder gases. One of these cases was a suizide (lethal temporal gunshot), in the other cases shots by another person: a) shot against the arm with large soft-tissue damage (survived); b) and c) shot against the neck with exceeding rupture of the soft tissues, minimal damage of the neck arteries and in one cases bilateral tears of the hypopharynx. In this case a delayed death after primarily well operated injury occurred after 12 days by bleeding into the airways from ruptured external carotid artery.

  9. 30 CFR 75.1103 - Automatic fire warning devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Automatic fire warning devices. 75.1103 Section... warning devices. [Statutory Provisions] On or before May 29, 1970, devices shall be installed on all such belts which will give a warning automatically when a fire occurs on or near such belt. The Secretary...

  10. 30 CFR 75.1103 - Automatic fire warning devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Automatic fire warning devices. 75.1103 Section... warning devices. [Statutory Provisions] On or before May 29, 1970, devices shall be installed on all such belts which will give a warning automatically when a fire occurs on or near such belt. The Secretary...

  11. 30 CFR 75.1103 - Automatic fire warning devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Automatic fire warning devices. 75.1103 Section... warning devices. [Statutory Provisions] On or before May 29, 1970, devices shall be installed on all such belts which will give a warning automatically when a fire occurs on or near such belt. The Secretary...

  12. 30 CFR 75.1103 - Automatic fire warning devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic fire warning devices. 75.1103 Section... warning devices. [Statutory Provisions] On or before May 29, 1970, devices shall be installed on all such belts which will give a warning automatically when a fire occurs on or near such belt. The Secretary...

  13. 30 CFR 75.1103 - Automatic fire warning devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Automatic fire warning devices. 75.1103 Section... warning devices. [Statutory Provisions] On or before May 29, 1970, devices shall be installed on all such belts which will give a warning automatically when a fire occurs on or near such belt. The Secretary...

  14. An analysis of shoot and scoot tactics

    DTIC Science & Technology

    2017-03-01

    firing multiple shots in the same location is preferable to moving immediately after firing one shot . Moving frequently reduces risk to artillery, but...preferable to moving immediately after firing one shot . Moving frequently reduces risk to artillery, but limits the artillery’s ability to inflict damage... study here. Thanks to his mistake (it might not be), I have completed a very tough matrix of 71 credits (56 grad level credits) in only one year. I

  15. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  16. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  17. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  18. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  19. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  20. 30 CFR 75.1103-3 - Automatic fire sensor and warning device systems; minimum requirements; general.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Automatic fire sensor and warning device systems; minimum requirements; general. 75.1103-3 Section 75.1103-3 Mineral Resources MINE SAFETY AND...-UNDERGROUND COAL MINES Fire Protection § 75.1103-3 Automatic fire sensor and warning device systems; minimum...

  1. 76 FR 58301 - Proposed Extension of Existing Information Collection; Automatic Fire Sensor and Warning Device...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-20

    .... Sec. 75.1103-8(b) and (c). MSHA expects to subsume these provisions into OMB 1219-0054, Fire....1103-5(a)(2)(ii) Automatic fire sensor and warning device systems and the package is at OMB for its 3.... 75.1103-5(a) Automatic fire warning devices; actions, response in October 2010; OMB 1219-0127...

  2. Wounding capacity of muzzle-gas pressure.

    PubMed

    Schyma, Christian

    2012-05-01

    Suicidal gunshot wounds that are caused by ammunition fired from a 9-mm Luger pistol, with direct contact between the gun muzzle and the victim's head, present a serious injury pattern even with full metal jacket bullets. Wound ballistic experiments were performed to clarify whether muzzle gases from the firearm have an additional wounding potential. Fifteen head models were prepared as follows: an acryl sphere measuring 14 cm in diameter was completely covered with a layer of silicon that was 3 mm thick. These spheres were filled with 10% gelatine. At 4°C, these models were fired at with a 9-mm Luger pistol, loaded with Quick Defense 1 expanding bullets. Five shots were fired with direct muzzle contact, one shot was fired from a distance of 10 cm, four shots were fired from a distance of 2 m, and five shots were fired from a distance of 4 m. Each projectile penetrated the model; all but one projectile deformed regularly. Each acryl sphere shattered into comminuted pieces but was held together by the silicon cover. The gelatine filling was then cut into slices 1 cm thick, and each slice was optically scanned. An evaluation was performed following both Fackler's Wound Profile method and the polygon procedure method. The pattern of gelatine disruption did not differ in shots from intermediate ranges, but the amount of gelatine destruction was always more extended in the case of muzzle contact shots. Depending on the section of the bullet path, crack lengths were 31% to 133% longer in contact shots. The first centimetre and the second half of the bullet path showed the greatest increase. The experimental findings prove the wounding capacity of muzzle gases.

  3. FIRE ALARM SYSTEM OUTDATED.

    ERIC Educational Resources Information Center

    CHANDLER, L.T.

    AN EFFICIENT FIRE ALARM SYSTEM SHOULD--(1) PROVIDE WARNING OF FIRES THAT START IN HIDDEN OR UNOCCUPIED LOCATIONS, (2) INDICATE WHERE THE FIRE IS, (3) GIVE ADVANCE WARNING TO FACULTY AND ADMINISTRATION SO THAT PANIC AND CONFUSION CAN BE AVOIDED AND ORDERLY EVACUATION OCCUR, (4) AUTOMATICALLY NOTIFY CITY FIRE HEADQUARTERS OF THE FIRE, (5) OPERATE BY…

  4. 30 CFR 75.1325 - Firing procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Shots shall be fired by a qualified person or a person working in the presence of and under the direction of a qualified person. (b) Only one face in a working place shall be blasted at a time, except... kerf and no more than a total of 20 shots connected in a single series are fired in the round. A permit...

  5. 30 CFR 75.1325 - Firing procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Shots shall be fired by a qualified person or a person working in the presence of and under the direction of a qualified person. (b) Only one face in a working place shall be blasted at a time, except... kerf and no more than a total of 20 shots connected in a single series are fired in the round. A permit...

  6. 30 CFR 75.1325 - Firing procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Shots shall be fired by a qualified person or a person working in the presence of and under the direction of a qualified person. (b) Only one face in a working place shall be blasted at a time, except... kerf and no more than a total of 20 shots connected in a single series are fired in the round. A permit...

  7. 30 CFR 75.1325 - Firing procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Shots shall be fired by a qualified person or a person working in the presence of and under the direction of a qualified person. (b) Only one face in a working place shall be blasted at a time, except... kerf and no more than a total of 20 shots connected in a single series are fired in the round. A permit...

  8. 30 CFR 75.1325 - Firing procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Shots shall be fired by a qualified person or a person working in the presence of and under the direction of a qualified person. (b) Only one face in a working place shall be blasted at a time, except... kerf and no more than a total of 20 shots connected in a single series are fired in the round. A permit...

  9. Effects of Body Armor Fit on Marksmanship Performance

    DTIC Science & Technology

    2016-09-01

    center target also used in the single target task. TPs fired one shot per target, following the order of target engagement. They repeated firing in...quickly TPs moved from one target to the next. TPs were allowed as much time for their first shot as needed and therefore, shot accuracy for the...FIT ON MARKSMANSHIP PERFORMANCE by Hyeg Joo Choi* K. Blake Mitchell Todd Garlie Jay McNamara Edward Hennessy and Jeremy Carson *Author

  10. 30 CFR 77.1102 - Warning signs; smoking and open flame.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Warning signs; smoking and open flame. 77.1102... COAL MINES Fire Protection § 77.1102 Warning signs; smoking and open flame. Signs warning against smoking and open flames shall be posted so they can be readily seen in areas or places where fire or...

  11. 30 CFR 77.1102 - Warning signs; smoking and open flame.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Warning signs; smoking and open flame. 77.1102... COAL MINES Fire Protection § 77.1102 Warning signs; smoking and open flame. Signs warning against smoking and open flames shall be posted so they can be readily seen in areas or places where fire or...

  12. Influence of Running on Pistol Shot Hit Patterns.

    PubMed

    Kerkhoff, Wim; Bolck, Annabel; Mattijssen, Erwin J A T

    2016-01-01

    In shooting scene reconstructions, risk assessment of the situation can be important for the legal system. Shooting accuracy and precision, and thus risk assessment, might be correlated with the shooter's physical movement and experience. The hit patterns of inexperienced and experienced shooters, while shooting stationary (10 shots) and in running motion (10 shots) with a semi-automatic pistol, were compared visually (with confidence ellipses) and statistically. The results show a significant difference in precision (circumference of the hit patterns) between stationary shots and shots fired in motion for both inexperienced and experienced shooters. The decrease in precision for all shooters was significantly larger in the y-direction than in the x-direction. The precision of the experienced shooters is overall better than that of the inexperienced shooters. No significant change in accuracy (shift in the hit pattern center) between stationary shots and shots fired in motion can be seen for all shooters. © 2015 American Academy of Forensic Sciences.

  13. [Injury patterns and roentgen findings in gunshot wounds with rare flint ammunition].

    PubMed

    Pollak, S; Lindermann, A

    1990-01-01

    Smoothbore shotgun barrels can fire cartridges with common pellet loads as well as shotgun slugs and rubber bullets. Other than conventional shot, the cylindrical Brenneke-type rifled shotgun slugs sometimes cause perforating wounds. The shotgun ammunition for use in self-defence can have a single projectile or several rubber pellets. Where the propellant is black powder, short range shots will probably leave searing marks and intensive soot deposits. Fired at close range, rubber bullets can penetrate through the skin into the body, fired at greater distance they cause contusions. A case of homicide (repeated firing with a 12-ga. pump gun) is used to present and discuss the injury patterns and X-ray findings after impact of Brenneke-type slugs and rubber bullets as well as of "classical" shot pellets.

  14. 30 CFR 75.1103-5 - Automatic fire warning devices; actions and response.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... hours after the belt is stopped, unless an examination for hot rollers and fire is made as prescribed in... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Automatic fire warning devices; actions and... OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire...

  15. 30 CFR 75.1103-5 - Automatic fire warning devices; actions and response.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... hours after the belt is stopped, unless an examination for hot rollers and fire is made as prescribed in... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Automatic fire warning devices; actions and... OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire...

  16. A Situational-Awareness System For Networked Infantry Including An Accelerometer-Based Shot-Identification Algorithm For Direct-Fire Weapons

    DTIC Science & Technology

    2016-09-01

    noise density and temperature sensitivity of these devices are all on the same order of magnitude. Even the worst- case noise density of the GCDC...accelerations from a handgun firing were distinct from other impulsive events on the wrist, such as using a hammer. Loeffler first identified potential shots by...spikes, taking various statistical parameters. He used a logistic regression model on these parameters and was able to classify 98.9% of shots

  17. 77 FR 58170 - Proposed Renewal of Existing Information Collection; Fire Protection (Underground Coal Mines)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-19

    ... the locations of automatic fire warning sensors and the intended air flow direction at these locations...) requires that a qualified person examine the automatic fire sensor and warning device systems on a weekly....1103-8(b) requires that a record of the weekly automatic fire sensor functional tests be maintained by...

  18. Real time forest fire warning and forest fire risk zoning: a Vietnamese case study

    NASA Astrophysics Data System (ADS)

    Chu, T.; Pham, D.; Phung, T.; Ha, A.; Paschke, M.

    2016-12-01

    Forest fire occurs seriously in Vietnam and has been considered as one of the major causes of forest lost and degradation. Several studies of forest fire risk warning were conducted using Modified Nesterov Index (MNI) but remaining shortcomings and inaccurate predictions that needs to be urgently improved. In our study, several important topographic and social factors such as aspect, slope, elevation, distance to residential areas and road system were considered as "permanent" factors while meteorological data were updated hourly using near-real-time (NRT) remotely sensed data (i.e. MODIS Terra/Aqua and TRMM) for the prediction and warning of fire. Due to the limited number of weather stations in Vietnam, data from all active stations (i.e. 178) were used with the satellite data to calibrate and upscale meteorological variables. These data with finer resolution were then used to generate MNI. The only significant "permanent" factors were selected as input variables based on the correlation coefficients that computed from multi-variable regression among true fire-burning (collected from 1/2007) and its spatial characteristics. These coefficients also used to suggest appropriate weight for computing forest fire risk (FR) model. Forest fire risk model was calculated from the MNI and the selected factors using fuzzy regression models (FRMs) and GIS based multi-criteria analysis. By this approach, the FR was slightly modified from MNI by the integrated use of various factors in our fire warning and prediction model. Multifactor-based maps of forest fire risk zone were generated from classifying FR into three potential danger levels. Fire risk maps were displayed using webgis technology that is easy for managing data and extracting reports. Reported fire-burnings thereafter have been used as true values for validating the forest fire risk. Fire probability has strong relationship with potential danger levels (varied from 5.3% to 53.8%) indicating that the higher potential risk, the more chance of fire happen. By adding spatial factors to continuous daily updated remote sensing based meteo-data, results are valuable for both mapping forest fire risk zones in short and long-term and real time fire warning in Vietnam. Key words: Near-real-time, forest fire warning, fuzzy regression model, remote sensing.

  19. 30 CFR 75.1324 - Methane concentration and tests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Methane concentration and tests. 75.1324... Methane concentration and tests. (a) No shot shall be fired in an area that contains 1.0 volume percent or more of methane. (b) Immediately before shots are fired, the methane concentration in a working place...

  20. 30 CFR 77.1303 - Explosives, handling and use.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... than one shot is to be fired at one time, blasting shall be done electrically or with detonating cord... shots are fired. (f) Explosives shall be kept separated from detonators until charging is started. (g... blunt and squared at one end and made of wood, nonsparking material, or of special plastic acceptable to...

  1. 30 CFR 77.1303 - Explosives, handling and use.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... than one shot is to be fired at one time, blasting shall be done electrically or with detonating cord... shots are fired. (f) Explosives shall be kept separated from detonators until charging is started. (g... blunt and squared at one end and made of wood, nonsparking material, or of special plastic acceptable to...

  2. 30 CFR 77.1303 - Explosives, handling and use.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... than one shot is to be fired at one time, blasting shall be done electrically or with detonating cord... shots are fired. (f) Explosives shall be kept separated from detonators until charging is started. (g... blunt and squared at one end and made of wood, nonsparking material, or of special plastic acceptable to...

  3. 30 CFR 77.1303 - Explosives, handling and use.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... than one shot is to be fired at one time, blasting shall be done electrically or with detonating cord... shots are fired. (f) Explosives shall be kept separated from detonators until charging is started. (g... blunt and squared at one end and made of wood, nonsparking material, or of special plastic acceptable to...

  4. 30 CFR 77.1303 - Explosives, handling and use.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... than one shot is to be fired at one time, blasting shall be done electrically or with detonating cord... shots are fired. (f) Explosives shall be kept separated from detonators until charging is started. (g... blunt and squared at one end and made of wood, nonsparking material, or of special plastic acceptable to...

  5. 30 CFR 75.1324 - Methane concentration and tests.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Methane concentration and tests. 75.1324... Methane concentration and tests. (a) No shot shall be fired in an area that contains 1.0 volume percent or more of methane. (b) Immediately before shots are fired, the methane concentration in a working place...

  6. 30 CFR 75.1103-5 - Automatic fire warning devices; actions and response.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... level reaches 10 parts per million above the established ambient level at any sensor location, automatic fire sensor and warning device systems shall provide an effective warning signal at the following... endangered and (ii) A map or schematic that shows the locations of sensors, and the intended air flow...

  7. 77 FR 5058 - Agency Information Collection Activities; Submission for OMB Review; Comment Request; Automatic...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-01

    ... for OMB Review; Comment Request; Automatic Fire Sensor and Warning Devices Systems; Examination and..., ``Automatic Fire Sensor and Warning Devices Systems,'' to the Office of Management and Budget (OMB) for review... and warning device systems are maintained and calibrated in order to function properly at all times...

  8. 14 CFR 25.857 - Cargo compartment classification.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... detector or fire detector system to give warning at the pilot or flight engineer station. (c) Class C. A... compartment but in which— (1) There is a separate approved smoke detector or fire detector system to give... a separate approved smoke or fire detector system to give warning at the pilot or flight engineer...

  9. 14 CFR 25.857 - Cargo compartment classification.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... detector or fire detector system to give warning at the pilot or flight engineer station. (c) Class C. A... compartment but in which— (1) There is a separate approved smoke detector or fire detector system to give... a separate approved smoke or fire detector system to give warning at the pilot or flight engineer...

  10. 14 CFR 25.857 - Cargo compartment classification.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... detector or fire detector system to give warning at the pilot or flight engineer station. (c) Class C. A... compartment but in which— (1) There is a separate approved smoke detector or fire detector system to give... a separate approved smoke or fire detector system to give warning at the pilot or flight engineer...

  11. 14 CFR 25.857 - Cargo compartment classification.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... detector or fire detector system to give warning at the pilot or flight engineer station. (c) Class C. A... compartment but in which— (1) There is a separate approved smoke detector or fire detector system to give... a separate approved smoke or fire detector system to give warning at the pilot or flight engineer...

  12. 14 CFR 25.857 - Cargo compartment classification.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... detector or fire detector system to give warning at the pilot or flight engineer station. (c) Class C. A... compartment but in which— (1) There is a separate approved smoke detector or fire detector system to give... a separate approved smoke or fire detector system to give warning at the pilot or flight engineer...

  13. 30 CFR 77.1909-1 - Use of nonpermissible explosives and nonpermissible shot-firing units; approval by Health and...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Use of nonpermissible explosives and nonpermissible shot-firing units; approval by Health and Safety District Manager. 77.1909-1 Section 77.1909-1...; approval by Health and Safety District Manager. Where the Coal Mine Health and Safety District Manager has...

  14. 16 CFR 1500.47 - Method for determining the sound pressure level produced by toy caps.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...'s instructions. (2) The oscilloscope shall be the storage type or one equipped with a camera. It...) Fire 10 shots at each of the six orientations, obtaining readings on the oscilloscope of the maximum peak voltage for each shot. Average the results of the 10 firings for each of the six orientations. (4...

  15. 16 CFR 1500.47 - Method for determining the sound pressure level produced by toy caps.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...'s instructions. (2) The oscilloscope shall be the storage type or one equipped with a camera. It...) Fire 10 shots at each of the six orientations, obtaining readings on the oscilloscope of the maximum peak voltage for each shot. Average the results of the 10 firings for each of the six orientations. (4...

  16. 16 CFR § 1500.47 - Method for determining the sound pressure level produced by toy caps.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...'s instructions. (2) The oscilloscope shall be the storage type or one equipped with a camera. It...) Fire 10 shots at each of the six orientations, obtaining readings on the oscilloscope of the maximum peak voltage for each shot. Average the results of the 10 firings for each of the six orientations. (4...

  17. 16 CFR 1500.47 - Method for determining the sound pressure level produced by toy caps.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...'s instructions. (2) The oscilloscope shall be the storage type or one equipped with a camera. It...) Fire 10 shots at each of the six orientations, obtaining readings on the oscilloscope of the maximum peak voltage for each shot. Average the results of the 10 firings for each of the six orientations. (4...

  18. Aircraft Instrument, Fire Protection, Warning, Communication, Navigation and Cabin Atmosphere Control System (Course Outline), Aviation Mechanics 3 (Air Frame): 9067.04.

    ERIC Educational Resources Information Center

    Dade County Public Schools, Miami, FL.

    This document presents an outline for a 135-hour course designed to familiarize the student with manipulative skills and theoretical knowledge concerning aircraft instrument systems like major flight and engine instruments; fire protection and fire fighting systems; warning systems and navigation systems; aircraft cabin control systems, such as…

  19. 32 CFR 552.100 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... designed or redesigned, made or remade, modified or remodified to automatically fire more than one shot by..., incendiary, blank, shotgun, black powder, and shot). Items shall only be considered as ammunition when loaded... smooth bore either a number of ball shot or a single projectile for each single pull of the trigger. (j...

  20. 32 CFR 552.100 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... designed or redesigned, made or remade, modified or remodified to automatically fire more than one shot by..., incendiary, blank, shotgun, black powder, and shot). Items shall only be considered as ammunition when loaded... smooth bore either a number of ball shot or a single projectile for each single pull of the trigger. (j...

  1. 32 CFR 552.100 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... designed or redesigned, made or remade, modified or remodified to automatically fire more than one shot by..., incendiary, blank, shotgun, black powder, and shot). Items shall only be considered as ammunition when loaded... smooth bore either a number of ball shot or a single projectile for each single pull of the trigger. (j...

  2. 32 CFR 552.100 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... designed or redesigned, made or remade, modified or remodified to automatically fire more than one shot by..., incendiary, blank, shotgun, black powder, and shot). Items shall only be considered as ammunition when loaded... smooth bore either a number of ball shot or a single projectile for each single pull of the trigger. (j...

  3. Computed tomographic evaluation to determine efficacy of euthanasia of yearling feedlot cattle by use of various firearm-ammunition combinations.

    PubMed

    Thomson, Daniel U; Wileman, Benjamin W; Rezac, Darrel J; Miesner, Matt D; Johnson-Neitman, Jennifer L; Biller, David S

    2013-11-01

    To evaluate with CT the efficacy of various combinations of firearms and ammunitions to penetrate and disrupt the brain tissue of cadaveric heads of feedlot steers. 42 fresh cadaveric heads of 12- to 18-month-old Bos taurus steers. For each of 7 combinations of firearms and ammunitions (.22-caliber rifle firing a long rifle 30-grain plated lead solid- or hollow-point round, .223-caliber carbine firing a 50-grain ballistic-tip round, 9-mm pistol firing a 124-grain total metal jacket round, .45-caliber automatic Colt pistol [ACP] firing a 230-grain full metal jacket round, and 12-gauge shotgun firing a 2.75-inch 1.25-ounce No. 4 birdshot shell or a 1-ounce rifled slug), 6 cadaveric heads were shot at an identical distance (3 m), angle, and anatomic location. Heads were scanned with third-generation CT, and images were evaluated to determine extent of penetration, projectile fragmentation, cranial fracture, and likelihood of instantaneous death (≥ 30% destruction of brain tissue or a brainstem lesion). RESULTS-41 of 42 skulls were penetrated by the projectile. Instantaneous death was considered a likely consequence for 83% (25/30) of heads shot with a rifle-fired .22-caliber solid-point round, pistol-fired .45-caliber ACP round, carbine-fired .223-caliber round, and shotgun-fired birdshot and slug. Of the 18 heads shot with pistol-fired 9-mm and .45-caliber ACP rounds and rifle-fired .22-caliber hollow-point rounds, only 6 had brainstem lesions. CONCLUSIONS AND CLINICAL RELEVANCE-Results suggested that gunshots delivered by all firearm-ammunition combinations except rifle-fired .22-caliber hollow-point rounds and pistol-fired 9-mm rounds were viable options for euthanasia of feedlot cattle.

  4. Efficient Flame Detection and Early Warning Sensors on Combustible Materials Using Hierarchical Graphene Oxide/Silicone Coatings.

    PubMed

    Wu, Qian; Gong, Li-Xiu; Li, Yang; Cao, Cheng-Fei; Tang, Long-Cheng; Wu, Lianbin; Zhao, Li; Zhang, Guo-Dong; Li, Shi-Neng; Gao, Jiefeng; Li, Yongjin; Mai, Yiu-Wing

    2018-01-23

    Design and development of smart sensors for rapid flame detection in postcombustion and early fire warning in precombustion situations are critically needed to improve the fire safety of combustible materials in many applications. Herein, we describe the fabrication of hierarchical coatings created by assembling a multilayered graphene oxide (GO)/silicone structure onto different combustible substrate materials. The resulting coatings exhibit distinct temperature-responsive electrical resistance change as efficient early warning sensors for detecting abnormal high environmental temperature, thus enabling fire prevention below the ignition temperature of combustible materials. After encountering a flame attack, we demonstrate extremely rapid flame detection response in 2-3 s and excellent flame self-extinguishing retardancy for the multilayered GO/silicone structure that can be synergistically transformed to a multiscale graphene/nanosilica protection layer. The hierarchical coatings developed are promising for fire prevention and protection applications in various critical fire risk and related perilous circumstances.

  5. Integrating remotely sensed fires for predicting deforestation for REDD.

    PubMed

    Armenteras, Dolors; Gibbes, Cerian; Anaya, Jesús A; Dávalos, Liliana M

    2017-06-01

    Fire is an important tool in tropical forest management, as it alters forest composition, structure, and the carbon budget. The United Nations program on Reducing Emissions from Deforestation and Forest Degradation (REDD+) aims to sustainably manage forests, as well as to conserve and enhance their carbon stocks. Despite the crucial role of fire management, decision-making on REDD+ interventions fails to systematically include fires. Here, we address this critical knowledge gap in two ways. First, we review REDD+ projects and programs to assess the inclusion of fires in monitoring, reporting, and verification (MRV) systems. Second, we model the relationship between fire and forest for a pilot site in Colombia using near-real-time (NRT) fire monitoring data derived from the Moderate Resolution Imaging Spectroradiometer (MODIS). The literature review revealed fire remains to be incorporated as a key component of MRV systems. Spatially explicit modeling of land use change showed the probability of deforestation declined sharply with increasing distance to the nearest fire the preceding year (multi-year model area under the curve [AUC] 0.82). Deforestation predictions based on the model performed better than the official REDD early-warning system. The model AUC for 2013 and 2014 was 0.81, compared to 0.52 for the early-warning system in 2013 and 0.68 in 2014. This demonstrates NRT fire monitoring is a powerful tool to predict sites of forest deforestation. Applying new, publicly available, and open-access NRT fire data should be an essential element of early-warning systems to detect and prevent deforestation. Our results provide tools for improving both the current MRV systems, and the deforestation early-warning system in Colombia. © 2017 by the Ecological Society of America.

  6. Artillery Survivability Model

    DTIC Science & Technology

    2016-06-01

    effectiveness of possible guns of the future. Different than this project, this thesis seeks to optimize the survival time of the artillery units and to find...one SME mentioned that the gun they were shot by provides more clues about subsequent shots. If we are taking mortar fire, falling rounds are...just be reloading their guns . If two rounds are necessary, two howitzers with a higher amount of the specified rounds are fired. After rounds have been

  7. Two-gun suicide by simultaneous shots to the head: interdisciplinary reconstruction on the basis of scene investigation, autopsy findings, GSR analysis and examination of firearms, bullets and cartridge cases.

    PubMed

    Grosse Perdekamp, Markus; Nadjem, Hadi; Merkel, Joachim; Braunwarth, Roland; Pollak, Stefan; Thierauf, Annette

    2011-07-01

    Suicidal shots fired simultaneously to the head from two handguns are rare. The authors report about a recent case in which a Smith & Wesson cal. 9 mm pistol and a Smith & Wesson cal. .357 Magnum revolver were used. Sitting on a sofa, a 33-year-old man (member of a shooting club) fired two simultaneous shots to the head; the pistol held in the left hand was discharged into the left temple, and the revolver held in the right hand was fired into the mouth. Both weapons remained in the respective hands. An upside-down muzzle imprint in the left temporal region and recoil injuries of a mandibular incisor, and the lower lip indicated that both the pistol and the revolver had been held in an inverted manner at the time of discharge. Blood stains (backspatter) and gunshot residues were present on both firing hands, whereas forward spatter originating from the exit wounds was deposited on the wall behind the suicide's head.

  8. Distortion of the temporary cavity and its influence on staining in firearm barrels.

    PubMed

    Schyma, Christian; Müller, Rolf; Brenčičová, Eva; Brünig, Julia

    2018-06-01

    After contact shots to the head, biological traces can be found inside the barrel of the firearm. Experimental protocols to generate this sort of staining, using 12 cm gelatin cubes containing thin foil bags filled with acrylic paint, human blood, and radiocontrast agent, have been developed. Previous research on shots fired at a distance has shown the underlay sustaining these gelatin cubes has an influence on experimental results. This study was conducted to investigate the role of the sustaining base of the gelatin blocks during contact shots, and its influence on the staining result inside firearm barrels. Eighteen contact shots were performed using 22 LR, 32 ACP (7.65 Browning) and 9 mm Luger semi-automatic pistols. With each pistol, shots were fired onto six gelatin cubes; three placed upon a rigid platform and three upon an elastic underlay. The shots were recorded by a high-speed video camera as they penetrated the gelatin cube. Any staining present inside the firearm barrels after the shots were fired was documented by endoscopy. Cross sections of the gelatin blocks were then compared to the high-speed video. It was found that the nature of the staining inside the barrel was not influenced by the underlay sustaining the target model. In the experiment using a 9 mm Luger, the rigid counterfort provoked a visible distortion of the temporary cavity, but, cross sectional analysis of the gelatin cubes did not reveal a relevant influence of the sustaining underlay on the crack length in the gelatin. This could be explained by a secondary expansion of the temporary cavity left by the projectile as a consequence of subsequent inflow of muzzle gases.

  9. Entrance, exit, and reentrance of one shot with a shotgun.

    PubMed

    Gulmann, C; Hougen, H P

    1999-03-01

    The case being reported is one of a homicidal shotgun fatality with an unusual wound pattern. A 34-year-old man was shot at close range with a 12-gauge shotgun armed with No. 5 birdshot ammunition. The shot entered the left axillary region, exited through the left infraclavicular region, and thereafter penetrated the left side of the neck, causing tearing of the left common carotid artery and the right internal carotid artery. The entrance wound in the axilla was larger than the other wounds, and before autopsy it was believed that the shotgun had been fired twice, causing one wound in the neck and one wound perforating the infraclavicular region and exiting through the left axillary region. Thus, this case shows that unusual wound patterns in shotgun fatalities can easily lead to incorrect assumptions with regard to number and direction of shots fired unless thorough investigation is carried out postmortem.

  10. Development of gas fire detection system using tunable diode laser absorption spectroscopy

    NASA Astrophysics Data System (ADS)

    Jiang, Y. L.; Li, G.; Yang, T.; Wang, J. J.

    2017-01-01

    The conventional fire detection methods mainly produce an alarm through detecting the changes in smoke concentration, flame radiation, heat and other physical parameters in the environment, but are unable to provide an early warning of a fire emergency. We have designed a gas fire detection system with a high detection sensitivity and high selectivity using the tunable semiconductor diode laser as a light source and combining wavelength modulation and harmonic detection technology. This system can invert the second harmonic signal obtained to obtain the concentration of carbon monoxide gas (a fire characteristic gas) so as to provide an early warning of fire. We reduce the system offset noise and the background noise generated due to the laser interference by deducting the system background spectrum lines from the second harmonic signal. This can also eliminate the interference of other gas spectral lines to a large extent. We detected the concentration of the carbon monoxide gas generated in smoldering sandalwood fire and open beech wood fire with the homemade fire simulator, and tested the lowest detectable limit of system. The test results show that the lowest detectable limit can reach 5×10-6 the system can maintain stable operation for a long period of time and can automatically trigger a water mist fire extinguishing system, which can fully meet the needs of early fire warning.

  11. [The forensic medical characteristics of the entrance bullet holes created by the shots from pneumatic rifles].

    PubMed

    Legin, G A; Bondarchuk, A O; Perebetjuk, A N

    2015-01-01

    The objective of the present study was to compare the injurious action of three types of the bullets for the pneumatic weapons shot from different distances using the Gamo pump air pistol and the BAM B22-1 pneumatic rifle. The following four kinds of the bullets were tested: "the fireball", "Luman cap 0.3", "Luman Field Target 0.68" and "DIABOLO". It was experimentally shown that the injurious action of the bullets fired from the same distance from the pneumatic weapons depends on the type of both the bullet and the weapon, as well as the properties of the target material. Specifically, the action of bullets fired from the piston pneumatic rifle remained stable whereas that of the bullets shot from the gas-balloon air pistol decreased as the gas was exhausted. The studies by the contact-diffusion method have demonstrated that the entrance bullet holes created by the shots from pneumatic weapons are surrounded by dispersed metal particles which makes it possible to estimate the shooting distance. Moreover, the bullets fired from the pneumatic weapons leave the muzzle face imprint on certain target materials.

  12. Factors Associated with Shooting Accuracy and Wounding Rate of Four Managed Wild Deer Species in the UK, Based on Anonymous Field Records from Deer Stalkers

    PubMed Central

    Aebischer, Nicholas J.; Wheatley, Christopher J.; Rose, Hugh R.

    2014-01-01

    The amount of wounding during routine culling is an important factor in the welfare of wild deer. Little information exists on factors determining shooting accuracy and wounding rates under field conditions in the UK. In this study, 102 anonymous stalkers collected data on the outcomes and circumstances of 2281 shots. Using hot-deck imputation and generalised linear mixed modelling, we related the probability that a shot hit its target, and the probability that the shot killed the deer if it was hit, to 28 variables describing the circumstances of the shot. Overall, 96% of deer were hit, of which 93% were killed outright. A reduced probability of hitting the target was associated with an uncomfortable firing position, too little time available, shooting off elbows or freehand, taking the head or upper neck as point of aim, a heavily obscured target, a distant target, shooting at females, lack of shooting practice and a basic (or no) stalker qualification. An increase in the likelihood of wounding was associated with an uncomfortable firing position, shooting with insufficient time, a distant target (only when time was not sufficient), a bullet weight below 75 grains, a target concealed in thicket or on the move and an area rarely stalked. To maximise stalking success and deer welfare, we recommend that stalkers ensure a comfortable firing position, use a gun rest, aim at the chest, use bullets heavier than 75 grains, avoid taking a rushed shot, shoot a distant animal only if there is plenty of time, fire only when the target is stationary, avoid shooting at an obscured animal, take care when the ground is unfamiliar, and do shooting practice at least once a month. The high miss rate of basic-level stalkers suggests that training should include additional firing practice under realistic shooting conditions. PMID:25334012

  13. Earthquake Warning Performance in Vallejo for the South Napa Earthquake

    NASA Astrophysics Data System (ADS)

    Wurman, G.; Price, M.

    2014-12-01

    In 2002 and 2003, Seismic Warning Systems, Inc. installed first-generation QuakeGuardTM earthquake warning devices at all eight fire stations in Vallejo, CA. These devices are designed to detect the P-wave of an earthquake and initiate predetermined protective actions if the impending shaking is estimated at approximately Modifed Mercalli Intensity V or greater. At the Vallejo fire stations the devices were set up to sound an audio alert over the public address system and to command the equipment bay doors to open. In August 2014, after more than 11 years of operating in the fire stations with no false alarms, the five units that were still in use triggered correctly on the MW 6.0 South Napa earthquake, less than 16 km away. The audio alert sounded in all five stations, providing fire fighters with 1.5 to 2.5 seconds of warning before the arrival of the S-wave, and the equipment bay doors opened in three of the stations. In one station the doors were disconnected from the QuakeGuard device, and another station lost power before the doors opened completely. These problems highlight just a small portion of the complexity associated with realizing actionable earthquake warnings. The issues experienced in this earthquake have already been addressed in subsequent QuakeGuard product generations, with downstream connection monitoring and backup power for critical systems. The fact that the fire fighters in Vallejo were afforded even two seconds of warning at these epicentral distances results from the design of the QuakeGuard devices, which focuses on rapid false positive rejection and ground motion estimates. We discuss the performance of the ground motion estimation algorithms, with an emphasis on the accuracy and timeliness of the estimates at close epicentral distances.

  14. High repetition rate Petawatt lasers

    NASA Astrophysics Data System (ADS)

    Roso, Luis

    2018-01-01

    Petawatt lasers are now available in a number of facilities around the world and are becoming a very useful tool in physics and engineering. Some of such lasers are able -or will be able soon- to fire at high repetition rates (one shot per second or more). Experiments at such repetition rates have certain peculiarities that are to be briefly exposed here, based on the author's experience with the Salamanca VEGA-3 laser. VEGA-3 is a 30 fs PW laser, firing one shot per second.

  15. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...

  16. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...

  17. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...

  18. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...

  19. Dust Detection by Curiosity ChemCam

    NASA Image and Video Library

    2013-04-08

    The ChemCam instrument on NASA Curiosity Mars rover fired its laser 50 times at its onboard graphite target showing spectral measurements from the first shot, which hit dust on the target, compared to spectral measurements of from the 50th shot.

  20. Fire and the Design of Educational Buildings. Building Bulletin 7. Sixth Edition.

    ERIC Educational Resources Information Center

    Department of Education and Science, London (England).

    This bulletin offers guidance on English school premises regulations applying to safety protection against fires in the following general areas: means of escape in case of fire; precautionary measures to prevent fire; fire warning systems and fire fighting; fire spreading speed; structures and materials resistant to fires; and damage control. It…

  1. A new type of shotgun ammunition produces unique wound characteristics.

    PubMed

    Nelson, Craig L; Winston, David C

    2007-01-01

    The Tucson Police Department, Tucson, AZ, has begun using the Polyshok Impact Reactive Projectile (IRP), a new type of shotgun ammunition that includes a lead bead core that travels within single, plastic-encased projectile. On impact, the core is released to distribute over a small area, thereby disintegrating on impact to reduce the likelihood of exit or collateral damage on missed shots. After a brief review of shotgun slug ballistics and wound characteristics and a discussion of the mechanism of the Polyshok IRP, we report the first death in the United States from this ammunition. Findings included a single entrance wound with plastic ammunition components and small lead particles recovered from the body, the combination of which normally would suggest a close-range shooting with birdshot. However, the characteristics of this ammunition create different patterns than are found with slugs or shot, so that a medical examiner unfamiliar with the Polyshok IRP could draw inaccurate conclusions about ammunition and range of fire. Because the single projectile fired from this ammunition is composed of both plastic and lead, plastic components are likely to be found within the wound at any range of fire, unlike traditional shot or slug ammunition. Also, the small size of lead particles found spread through the wound cavity would ordinarily suggest a small-size shot, whereas the external appearance of the wound (a single entrance with no dispersion of shot) and the pattern of tissue destruction are more consistent with the patterns of injury associated with shotgun slugs.

  2. 30 CFR 77.1102 - Warning signs; smoking and open flame.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Warning signs; smoking and open flame. 77.1102 Section 77.1102 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE... COAL MINES Fire Protection § 77.1102 Warning signs; smoking and open flame. Signs warning against...

  3. 30 CFR 77.1102 - Warning signs; smoking and open flame.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Warning signs; smoking and open flame. 77.1102 Section 77.1102 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE... COAL MINES Fire Protection § 77.1102 Warning signs; smoking and open flame. Signs warning against...

  4. 30 CFR 77.1102 - Warning signs; smoking and open flame.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Warning signs; smoking and open flame. 77.1102 Section 77.1102 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE... COAL MINES Fire Protection § 77.1102 Warning signs; smoking and open flame. Signs warning against...

  5. Experimental Results from Railgun Firings Involving Magnetic Flux Probes.

    DTIC Science & Technology

    1986-12-01

    record is given as 6.6 x 102 As. A time of 6.6 x 102 As from shot -start falls in the region of noise past the second minimum in Figure 2. Thus the minima...capacitor bank occurred about 200 ps after shot -start. The duration of a firing in the MRAP series was approximately 750 us. The magnetic probes used...designated by a Ŗ" or a ŗ". The transverse probe is designated as MCT in Figure 1. Pieces of aluminium foil weighing about 0.012 g were used to generate

  6. Environmental Impact of Controlled-Source Explosions in Ethiopia (Project EAGLE): Surface Shaking, Ground Velocities, and Effects on Buildings

    NASA Astrophysics Data System (ADS)

    Les, A.; Klemperer, S. L.; Keranen, K.; Khan, A.; Maguire, P.

    2003-12-01

    In January 2003, as part of the Ethiopia-Afar Geoscientific Lithospheric Experiment (EAGLE) we conducted a refraction and wide-angle reflection survey of the Main Ethiopian Rift. 757 RefTek "Texan" seismographs with vertical geophones were deployed in 400 km-long axial and cross-rift lines, with another 231 in a central 3D array 100 km in diameter. An 80-instrument passive array of intermediate and broadband sensors was active during our experiment. We recorded 19 borehole shots loaded in nominal 50-meter boreholes, 2 quarry shots, and 2 lake shots. The shots ranged in size from 50-5750 kg, with the most common shot size being 1 tonne. Prior to loading each shot-hole, we measured distances between shots and the nearest structure, typically un-reinforced mud-and-wood houses, occasionally concrete irrigation ditches and aqueducts. We then used semi-empirical formulae derived by Oriard (Hendron and Oriard, 1972) to calculate expected maximum and minimum bounds on ground velocity at these structures, and selected an appropriate shot size to keep the predicted velocity below the "threshold for cosmetic damage", or 2 inches per second, at the most vulnerable structure. The Oriard formulae are derived from measurements associated with blasting for mining and civil engineering purposes and may not accurately predict the ground velocity from the source depths and explosive type used in the EAGLE and other controlled-source experiments. A detailed, trace-by-trace analysis of maximum ground velocities at our closest seismographs can provide data that will be useful in planning future large-scale seismic experiments. Preliminary results from traces within 20 km of our borehole shots suggest that maximum recorded ground velocities were within or below the maximum-minimum range predicted by Oriard, and hence that larger shot sizes could have been used with acceptable risks. A lake shot fired at the optimum depth (84 m for a 1 tonne shot) produced ground velocities that exceeded the predicted maximum at a few recodrers. However, optimum-depth shots are typically a significant distance offshore (c. 2.3 km for our shot) because of the required depth, so are unlikely to present a hazard to onshore structures. A lake shot fired in a shallower lake at half the optimum depth did not produce ground-velocities that exceed the Oriard maximum. Although we fired shots within 100 m of an unreinforced concrete aqueduct, and within 200 m of poorly engineered native buildings in poor structural condition, no damage was recorded. Our "Texan" seismometers recorded only vertical component velocity, using 4.5 Hz geophones. After removal of the geophone response the peak vertical velocity is typically measured at about 3 Hz and occurs shortly after the first arrival, presumably due to surface waves (ground roll). We are currently extending our analysis to include data from broadband, three-component recorders.

  7. 30 CFR 75.1103-6 - Automatic fire sensors; actuation of fire suppression systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Protection § 75.1103-6 Automatic fire sensors; actuation of fire suppression systems. Point-type heat sensors or automatic fire sensor and warning device systems may be used to actuate deluge-type water systems... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic fire sensors; actuation of fire...

  8. 30 CFR 75.1103-6 - Automatic fire sensors; actuation of fire suppression systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Automatic fire sensors; actuation of fire... Protection § 75.1103-6 Automatic fire sensors; actuation of fire suppression systems. Point-type heat sensors or automatic fire sensor and warning device systems may be used to actuate deluge-type water systems...

  9. 30 CFR 75.1103-6 - Automatic fire sensors; actuation of fire suppression systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Automatic fire sensors; actuation of fire... Protection § 75.1103-6 Automatic fire sensors; actuation of fire suppression systems. Point-type heat sensors or automatic fire sensor and warning device systems may be used to actuate deluge-type water systems...

  10. 30 CFR 75.1103-6 - Automatic fire sensors; actuation of fire suppression systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Automatic fire sensors; actuation of fire... Protection § 75.1103-6 Automatic fire sensors; actuation of fire suppression systems. Point-type heat sensors or automatic fire sensor and warning device systems may be used to actuate deluge-type water systems...

  11. 30 CFR 75.1103-6 - Automatic fire sensors; actuation of fire suppression systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Automatic fire sensors; actuation of fire... Protection § 75.1103-6 Automatic fire sensors; actuation of fire suppression systems. Point-type heat sensors or automatic fire sensor and warning device systems may be used to actuate deluge-type water systems...

  12. Fire Safety for Retired Adults: Participant's Coursebook.

    ERIC Educational Resources Information Center

    Walker (Bonnie) and Associates, Inc., Crofton, MD.

    The risk of dying from fire increases substantially among older adults. This document contains a collection of fire safety information for elderly people. Information includes procedures to follow in case of fire and early warning technologies such as smoke alarms. The booklet describes potential sources of fires (smoking, home heating, kitchens,…

  13. Possible influences on bullet trajectory deflection in ballistic gelatine.

    PubMed

    Riva, Fabiano; Kerkhoff, Wim; Bolck, Annabel; Mattijssen, Erwin J A T

    2017-02-01

    The influence of the distance to the top and bottom of a gelatine block and to bullet tracks from previously fired shots on a bullet's trajectory, when passing through ballistic gelatine, was studied. No significant difference in deflection was found when trajectories of 9mm Luger bullets, fired at a 3.5cm distance to the top and bottom of a gelatine block and to bullet tracks from previously fired shots, were compared to trajectories of bullets fired 7cm or more away from any of the aforementioned aspects. A surprisingly consistent 6.5° absolute deflection angle was found when these bullets passed through 22.5 to 23.5cm of ballistic gelatine. The projection angle, determined by the direction of the deflection, appeared to be random. The consistent absolute angle, in combination with the random projection angle, resulted in a cone-like deflection pattern. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  14. Fire Won't Wait--Plan Your Escape!

    ERIC Educational Resources Information Center

    PTA Today, 1991

    1991-01-01

    Discusses the importance of home fire escape drills, detailing fire safety plans. Early detection and warning (smoke detectors) coupled with well-rehearsed escape plans help prevent serious injury. Children need to be taught about fire safety beginning at a very early age. (SM)

  15. 46 CFR 131.817 - Carbon dioxide warning signs.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Carbon dioxide warning signs. 131.817 Section 131.817 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.817 Carbon dioxide warning signs. Each entrance...

  16. 46 CFR 131.817 - Carbon dioxide warning signs.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Carbon dioxide warning signs. 131.817 Section 131.817 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.817 Carbon dioxide warning signs. Each entrance...

  17. 46 CFR 131.817 - Carbon dioxide warning signs.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Carbon dioxide warning signs. 131.817 Section 131.817 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.817 Carbon dioxide warning signs. Each entrance...

  18. Did a "lucky shot" sink the submarine H.L. Hunley?

    PubMed

    Lance, Rachel M; Warder, Henry; Bass, Cameron R Dale

    2017-01-01

    The H.L. Hunley was the first submarine to be successful in combat, sinking the Union vessel Housatonic outside Charleston Harbor in 1864 during the Civil War. However, despite marking a milestone in military history, little is known about this vessel or why it sank. One popular theory is the "lucky shot" theory: the hypothesis that small arms fire from the crew of the Housatonic may have sufficiently damaged the submarine to sink it. However, ballistic experiments with cast iron samples, analysis of historical experiments firing Civil War-era projectiles at cast iron samples, and calculation of the tidal currents and sinking trajectory of the submarine indicate that this theory is not likely. Based on our results, the "lucky shot" theory does not explain the sinking of the world's first successful combat submarine. Published by Elsevier B.V.

  19. Alternative Fuels Data Center: Propane Related Links

    Science.gov Websites

    Amerex Corporation's Vehicle Fire Suppression Systems are designed to warn the vehicle operator and suppress the fire, protecting both equipment and employees. Automatic systems suppress the fire in its

  20. Heavy metals in flamingos (Phoenicopterus ruber) from Italian wetlands: The problem of ingestion of lead shot

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ancora, Stefania; Bianchi, Nicola; Leonzio, Claudio

    2008-06-15

    Waterbirds are exposed to many contaminants, including lead from ingestion of shot and fishing sinkers. Lead poisoning had never been reported in flamingos wintering in Italian wetlands. Our investigation stems from a case of four flamingos found dead in Tuscany in 2002 with numerous lead shot in their gizzards. We therefore considered other specimens found dead in different Italian wetlands. Many lead shot found in gizzards and lead tissue concentrations confirmed the hypothesis of lead poisoning in two of the seven specimens analysed: concentrations in liver, kidney, and bone were 361.3, 265.09, and 43.31 {mu}g/g d.w., respectively. Lead organotropism wasmore » typical of acute poisoning. Cadmium and mercury were also determined, and found to be in line with what little data are available on this species in the literature. Although Italy recently endorsed the African-Eurasian Waterbird Agreement (AEWA) prohibiting use of lead shot for hunting in wetlands, our results reveal a first case of lead shot poisoning in flamingos wintering in Italian wetlands. This evidence sounds a further warning of the problem of spent lead shot in countries where hunting in wetlands is not strictly regulated.« less

  1. High-voltage, low-inductance gas switch

    DOEpatents

    Gruner, Frederick R.; Stygar, William A.

    2016-03-22

    A low-inductance, air-insulated gas switch uses a de-enhanced annular trigger ring disposed between two opposing high voltage electrodes. The switch is DC chargeable to 200 kilovolts or more, triggerable, has low jitter (5 ns or less), has pre-fire and no-fire rates of no more than one in 10,000 shots, and has a lifetime of greater than 100,000 shots. Importantly, the switch also has a low inductance (less than 60 nH) and the ability to conduct currents with less than 100 ns rise times. The switch can be used with linear transformer drives or other pulsed-power systems.

  2. 46 CFR 97.37-11 - Carbon dioxide warning signs.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Carbon dioxide warning signs. 97.37-11 Section 97.37-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-11 Carbon dioxide warning signs. Each...

  3. 46 CFR 97.37-11 - Carbon dioxide warning signs.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Carbon dioxide warning signs. 97.37-11 Section 97.37-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-11 Carbon dioxide warning signs. Each...

  4. 46 CFR 97.37-11 - Carbon dioxide warning signs.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Carbon dioxide warning signs. 97.37-11 Section 97.37-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-11 Carbon dioxide warning signs. Each...

  5. Early warning of active fire hotspots through NASA FIRMS fire information system

    NASA Astrophysics Data System (ADS)

    Ilavajhala, S.; Davies, D.; Schmaltz, J. E.; Murphy, K. J.

    2014-12-01

    Forest fires and wildfires can threaten ecosystems, wildlife, property, and often, large swaths of populations. Early warning of active fire hotspots plays a crucial role in planning, managing, and mitigating the damaging effects of wildfires. The NASA Fire Information for Resource Management System (FIRMS) has been providing active fire location information to users in easy-to-use formats for the better part of last decade, with a view to improving the alerting mechanisms and response times to fight forest and wildfires. FIRMS utilizes fires flagged as hotspots by the MODIS instrument flying aboard the Aqua and Terra satellites and sends early warning of detected hotspots via email in near real-time or as daily and weekly summaries. The email alerts can also be customized to send alerts for a particular region of interest, a country, or a specific protected area or park. In addition, a web mapping component, named "Web Fire Mapper" helps query and visualize hotspots. A newer version of Web Fire Mapper is being developed to enhance the existing visualization and alerting capabilities. Plans include supporting near real-time imagery from Aqua and Terra satellites to provide a more helpful context while viewing fires. Plans are also underway to upgrade the email alerts system to provide mobile-formatted messages and short text messages (SMS). The newer version of FIRMS will also allow users to obtain geo-located image snapshots, which can be imported into local GIS software by stakeholders to help further analyses. This talk will discuss the FIRMS system, its enhancements and its role in helping map, alert, and monitor fire hotspots by providing quick data visualization, querying, and download capabilities.

  6. 30 CFR 57.4330 - Surface firefighting, evacuation, and rescue procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4330 Surface... coordinated in advance with available firefighting organizations. (b) Fire alarm procedures or systems shall be established to promptly warn every person who could be endangered by a fire. (c) Fire alarm...

  7. 30 CFR 56.4330 - Firefighting, evacuation, and rescue procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Fire Prevention and Control Firefighting Procedures/alarms/drills § 56.4330 Firefighting, evacuation... organizations. (b) Fire alarm procedures or systems shall be established to pomptly warn every person who could be endangered by a fire. (c) Fire alarm systems shall be maintained in operable condition. ...

  8. 30 CFR 56.4330 - Firefighting, evacuation, and rescue procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Fire Prevention and Control Firefighting Procedures/alarms/drills § 56.4330 Firefighting, evacuation... organizations. (b) Fire alarm procedures or systems shall be established to pomptly warn every person who could be endangered by a fire. (c) Fire alarm systems shall be maintained in operable condition. ...

  9. 30 CFR 57.4330 - Surface firefighting, evacuation, and rescue procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4330 Surface... coordinated in advance with available firefighting organizations. (b) Fire alarm procedures or systems shall be established to promptly warn every person who could be endangered by a fire. (c) Fire alarm...

  10. 30 CFR 56.4330 - Firefighting, evacuation, and rescue procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Fire Prevention and Control Firefighting Procedures/alarms/drills § 56.4330 Firefighting, evacuation... organizations. (b) Fire alarm procedures or systems shall be established to pomptly warn every person who could be endangered by a fire. (c) Fire alarm systems shall be maintained in operable condition. ...

  11. 30 CFR 56.4330 - Firefighting, evacuation, and rescue procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Fire Prevention and Control Firefighting Procedures/alarms/drills § 56.4330 Firefighting, evacuation... organizations. (b) Fire alarm procedures or systems shall be established to pomptly warn every person who could be endangered by a fire. (c) Fire alarm systems shall be maintained in operable condition. ...

  12. 30 CFR 57.4330 - Surface firefighting, evacuation, and rescue procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4330 Surface... coordinated in advance with available firefighting organizations. (b) Fire alarm procedures or systems shall be established to promptly warn every person who could be endangered by a fire. (c) Fire alarm...

  13. 30 CFR 57.4330 - Surface firefighting, evacuation, and rescue procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 57.4330 Surface... coordinated in advance with available firefighting organizations. (b) Fire alarm procedures or systems shall be established to promptly warn every person who could be endangered by a fire. (c) Fire alarm...

  14. 29 CFR 1926.909 - Firing the blast.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Firing the blast. (a) A code of blasting signals equivalent to Table U-1, shall be posted on one or more... blasts 5 minutes prior to blast signal. Blast Signal—A series of short blasts 1 minute prior to the shot...

  15. 29 CFR 1926.909 - Firing the blast.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Firing the blast. (a) A code of blasting signals equivalent to Table U-1, shall be posted on one or more... blasts 5 minutes prior to blast signal. Blast Signal—A series of short blasts 1 minute prior to the shot...

  16. 29 CFR 1926.909 - Firing the blast.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Firing the blast. (a) A code of blasting signals equivalent to Table U-1, shall be posted on one or more... blasts 5 minutes prior to blast signal. Blast Signal—A series of short blasts 1 minute prior to the shot...

  17. 29 CFR 1926.909 - Firing the blast.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Firing the blast. (a) A code of blasting signals equivalent to Table U-1, shall be posted on one or more... blasts 5 minutes prior to blast signal. Blast Signal—A series of short blasts 1 minute prior to the shot...

  18. 29 CFR 1926.909 - Firing the blast.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Firing the blast. (a) A code of blasting signals equivalent to Table U-1, shall be posted on one or more... blasts 5 minutes prior to blast signal. Blast Signal—A series of short blasts 1 minute prior to the shot...

  19. A DUEL WITH SILENT NOISY GUN VERSUS NOISY GUN.

    DTIC Science & Technology

    A two person duel where the first person has one silent and one noisy shot to be fired in that order and the second person has one noisy shot is...analized for arbitrary continuously increasing, as the distance between duelists decreases, accuracy functions. The value of the duel and optimal strategies are computed. (Author)

  20. Virtual targeting in three-dimensional space with sound and light interference

    NASA Astrophysics Data System (ADS)

    Chua, Florence B.; DeMarco, Robert M.; Bergen, Michael T.; Short, Kenneth R.; Servatius, Richard J.

    2006-05-01

    Law enforcement and the military are critically concerned with the targeting and firing accuracy of opponents. Stimuli which impede opponent targeting and firing accuracy can be incorporated into defense systems. An automated virtual firing range was developed to assess human targeting accuracy under conditions of sound and light interference, while avoiding dangers associated with live fire. This system has the ability to quantify sound and light interference effects on targeting and firing accuracy in three dimensions. This was achieved by development of a hardware and software system that presents the subject with a sound or light target, preceded by a sound or light interference. SonyXplod. TM 4-way speakers present sound interference and sound targeting. The Martin ® MiniMAC TM Profile operates as a source of light interference, while a red laser light serves as a target. A tracking system was created to monitor toy gun movement and firing in three-dimensional space. Data are collected via the Ascension ® Flock of Birds TM tracking system and a custom National Instrument ® LabVIEW TM 7.0 program to monitor gun movement and firing. A test protocol examined system parameters. Results confirm that the system enables tracking of virtual shots from a fired simulation gun to determine shot accuracy and location in three dimensions.

  1. [Determination of the barrel inclination of the AK-74 assault rifle from the specific features of soot deposition after a shot around the inlet wounds caused by a burst of shots].

    PubMed

    Gusarov, A A; Makarov, I Yu; Fetisov, V A

    The specific features of soot deposition after a shot fired from the Kalashnikov AK-74 assault rifle are determined by the influence of the multiple factors, with the effect of the muzzle brake (MB) designed to enhance fire density and decrease the fire recoil energy being prevalent over other factors. The special windows, slots and holes in the muzzle brake mechanism are responsible for the appearance of the specific topographic features of soot deposition formed by the combustion gases passing through the assembly. Apart from the characteristic butterfly-shaped soot deposition patterns that appear due to the presence of two windows in the muzzle brake assembly, the additional zones of soot deposition can sometimes be seen on the objects and targets due to the escape of the combustion gases through the MB compensator openings. This phenomenon enables a forensic medical expert to determine orientation and position of the AK-74 rifle with respect to the shooting target. This article reports the results of the forensic medical expertise of a serviceman who died from the injuries to the head inflicted by a burst of shots fired from the Kalashnikov AK-74 assault rifle. The direction of the wound canals and their topographic patterns (including the shape, size, number, and localization) of soot deposition around the inlet wounds made it possible to determine the position of the AK-12 rifle with respect to the affected regions of the head and thereby to prove that the death of the serviceman was a result of suicide.

  2. Alaska and Yukon Fires

    Atmospheric Science Data Center

    2014-05-15

    article title:  Smoke Signals from the Alaska and Yukon Fires   ... the Yukon Territory from mid-June to mid-July, 2004. Thick smoke particles filled the air during these fires, prompting Alaskan officials to issue air quality warnings. Some of the smoke from these fires was detected as far away as New Hampshire. These ...

  3. 46 CFR 78.47-11 - Carbon dioxide warning signs.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 3 2014-10-01 2014-10-01 false Carbon dioxide warning signs. 78.47-11 Section 78.47-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-11 Carbon dioxide warning signs. Each entrance to a space...

  4. 46 CFR 78.47-11 - Carbon dioxide warning signs.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 3 2012-10-01 2012-10-01 false Carbon dioxide warning signs. 78.47-11 Section 78.47-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-11 Carbon dioxide warning signs. Each entrance to a space...

  5. 46 CFR 196.37-8 - Carbon dioxide warning signs.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Carbon dioxide warning signs. 196.37-8 Section 196.37-8 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS OPERATIONS Markings for Fire and Emergency Equipment, etc. § 196.37-8 Carbon dioxide warning signs. Each entrance to a...

  6. 46 CFR 196.37-8 - Carbon dioxide warning signs.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Carbon dioxide warning signs. 196.37-8 Section 196.37-8 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS OPERATIONS Markings for Fire and Emergency Equipment, etc. § 196.37-8 Carbon dioxide warning signs. Each entrance to a...

  7. 46 CFR 78.47-11 - Carbon dioxide warning signs.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 3 2013-10-01 2013-10-01 false Carbon dioxide warning signs. 78.47-11 Section 78.47-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-11 Carbon dioxide warning signs. Each entrance to a space...

  8. 46 CFR 196.37-8 - Carbon dioxide warning signs.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Carbon dioxide warning signs. 196.37-8 Section 196.37-8 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS OPERATIONS Markings for Fire and Emergency Equipment, etc. § 196.37-8 Carbon dioxide warning signs. Each entrance to a...

  9. Application of the Haines Index in the fire warning system

    NASA Astrophysics Data System (ADS)

    Kalin, Lovro; Marija, Mokoric; Tomislav, Kozaric

    2016-04-01

    Croatia, as all Mediterranean countries, is strongly affected by large wildfires, particularly in the coastal region. In the last two decades the number and intensity of fires has been significantly increased, which is unanimously associated with climate change, e.g. global warming. More extreme fires are observed, and the fire-fighting season has been expanded to June and September. The meteorological support for fire protection and planning is therefore even more important. At the Meteorological and Hydrological Service of Croatia a comprehensive monitoring and warning system has been established. It includes standard components, such as short term forecast of Fire Weather Index (FWI), but long range forecast as well. However, due to more frequent hot and dry seasons, FWI index often does not provide additional information of extremely high fire danger, since it regularly takes the highest values for long periods. Therefore the additional tools have been investigated. One of widely used meteorological products is the Haines index (HI). It provides information of potential fire growth, taking into account only the vertical instability of the atmosphere, and not the state of the fuel. Several analyses and studies carried out at the Service confirmed the correlation of high HI values with large and extreme fires. The Haines index forecast has been used at the Service for several years, employing European Centre for Medium Range Weather Forecast (ECMWF) global prediction model, as well as the limited-area Aladin model. The verification results show that these forecast are reliable, when compared to radiosonde measurements. All these results provided the introduction of the additional fire warnings, that are issued by the Service's Forecast Department.

  10. Bits or Shots in Combat? The Generalized Deitchman Model of Guerrilla Warfare

    DTIC Science & Technology

    2013-08-13

    fire; absence of intelligence leads to unaimed fire, dependent on targets’ density. We propose a new Lanchester -type model that mixes aimed and unaimed...military hardware. The idea of modeling the trade-off between firepower and intelligence in a Lanchester setting was first suggested by Schreiber [4...of intelligence leads to unaimed fire, dependent on targets? density. We propose a new Lanchester -type model that mixes aimed and unaimed fire, the

  11. Experimental effect of shots caused by projectiles fired from air guns with kinetic energy below 17 J.

    PubMed

    Smędra-Kaźmirska, Anna; Barzdo, Maciej; Kędzierski, Maciej; Antoszczyk, Łukasz; Szram, Stefan; Berent, Jarosław

    2013-09-01

    Pursuant to the Polish Weapons and Ammunitions Law (Legal Gazette No 53/1999 item 549 with subsequent amendments), air guns with kinetic energy of the fired projectiles below 17 J are not regarded as weapons. The aim of the study was to assess the potential effect of shots caused by projectiles of various mass and structure fired from air guns with kinetic energy below 17 J on human soft tissues. As a model of soft tissue, we used 20% gelatin blocks. After shooting, we measured the depth of gelatin block penetration by pellets fired from various distances and compared these results with autopsy findings. The results demonstrated that examined pneumatic guns may cause serious injuries, including damage to the pleura, pericardium, liver, spleen, kidneys, femoral artery, and thoracic and abdominal aorta. Experiment shown that gelatin blocks do not reflect fully the properties of the human body. © 2013 American Academy of Forensic Sciences.

  12. AEGIS: a wildfire prevention and management information system

    Treesearch

    Kostas Kalabokidis; Alan Ager; Mark Finney; Nikos Athanasis; Palaiologos Palaiologou; Christos Vasilakos

    2016-01-01

    We describe a Web-GIS wildfire prevention and management platform (AEGIS) developed as an integrated and easy-to-use decision support tool to manage wildland fire hazards in Greece (http://aegis.aegean.gr). The AEGIS platform assists with early fire warning, fire planning, fire control and coordination of firefighting forces by providing online access to...

  13. Fire Detector

    NASA Technical Reports Server (NTRS)

    1978-01-01

    An early warning fire detection sensor developed for NASA's Space Shuttle Orbiter is being evaluated as a possible hazard prevention system for mining operations. The incipient Fire Detector represents an advancement over commercially available smoke detectors in that it senses and signals the presence of a fire condition before the appearance of flame and smoke, offering an extra margin of safety.

  14. If it looks like a duck and quacks like a duck…: Energy "shots" should be regulated as energy drinks in Canada.

    PubMed

    Hammond, David; Reid, Jessica L

    2016-06-27

    In 2012, Health Canada transitioned caffeinated energy drinks from Natural Health Product to Food and Drug classification and regulations, implementing temporary guidelines with requirements such as caffeine content limits, mandatory cautionary labelling, and restrictions on health claims. "Energy shots" often contain as much or more caffeine compared to energy drinks and have been associated with a similar number of adverse health events. However, current requirements for energy drinks do not apply to energy shots, which remain classified as "natural health products" on the basis that they are "not consumed or perceived as foods" in the same way as energy drinks. An online survey was conducted with Canadian youth and young adults aged 12-24 years (N = 2040) in October 2014 to examine perceptions of energy shots. Respondents viewed an image of a popular energy shot and were asked which term best described it, with six randomly-ordered options. The vast majority (78.8%) perceived the energy shot as an "energy drink" (vs. "supplement", "vitamin drink", "natural health product", "soft drink" or "food product"). Given consumer perceptions and the similarity in product constituents, there is little basis for regulating energy shots differently from energy drinks; these products should be subject to similar labelling and health warning requirements.

  15. Changing Weather Extremes Call for Early Warning of Potential for Catastrophic Fire

    NASA Astrophysics Data System (ADS)

    Boer, Matthias M.; Nolan, Rachael H.; Resco De Dios, Víctor; Clarke, Hamish; Price, Owen F.; Bradstock, Ross A.

    2017-12-01

    Changing frequencies of extreme weather events and shifting fire seasons call for enhanced capability to forecast where and when forested landscapes switch from a nonflammable (i.e., wet fuel) state to the highly flammable (i.e., dry fuel) state required for catastrophic forest fires. Current forest fire danger indices used in Europe, North America, and Australia rate potential fire behavior by combining numerical indices of fuel moisture content, potential rate of fire spread, and fire intensity. These numerical rating systems lack the physical basis required to reliably quantify forest flammability outside the environments of their development or under novel climate conditions. Here, we argue that exceedance of critical forest flammability thresholds is a prerequisite for major forest fires and therefore early warning systems should be based on a reliable prediction of fuel moisture content plus a regionally calibrated model of how forest fire activity responds to variation in fuel moisture content. We demonstrate the potential of this approach through a case study in Portugal. We use a physically based fuel moisture model with historical weather and fire records to identify critical fuel moisture thresholds for forest fire activity and then show that the catastrophic June 2017 forest fires in central Portugal erupted shortly after fuels in the region dried out to historically unprecedented levels.

  16. Unretrieved shooting loss of mourning doves in north-central South Carolina

    USGS Publications Warehouse

    Haas, G.H.

    1977-01-01

    Unretrieved loss for mourning doves (Zenaida macroura) in north-central South Carolina was between 27 and 41 percent of the retrieved kill for the 1973 through 1975 hunting seasons based on 1,396 doves shot by 281 hunters. Dove hunters hunted in groups, fired 8.6 shots per retrieved dove, and engaged in a substantial number of illegal activities. Increased dove populations and hunter bag resulted in increased unretrieved loss, numbers of shots per bagged bird, and illegal activities. Retriever dogs increased the efficiency of dove hunters.

  17. Economic Impact of Fire Weather Forecasts

    Treesearch

    Don Gunasekera; Graham Mills; Mark Williams

    2006-01-01

    Southeastern Australia, where the State of Victoria is located is regarded as one of the most fire prone areas in the world. The Australian Bureau of Meteorology provides fire weather services in Victoria as part of a national framework for the provision of such services. These services range from fire weather warnings to special forecasts for hazard reduction burns....

  18. 49 CFR 176.325 - Smoking or open flame and posting of warning signs.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 2 2013-10-01 2013-10-01 false Smoking or open flame and posting of warning signs... Smoking or open flame and posting of warning signs. (a) Smoking or the use of open flame is prohibited in... material. (b) A sign carrying the legend: FLAMMABLE VAPORS KEEP LIGHTS AND FIRE AWAY NO SMOKING must be...

  19. 49 CFR 176.325 - Smoking or open flame and posting of warning signs.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false Smoking or open flame and posting of warning signs... Smoking or open flame and posting of warning signs. (a) Smoking or the use of open flame is prohibited in... material. (b) A sign carrying the legend: FLAMMABLE VAPORS KEEP LIGHTS AND FIRE AWAY NO SMOKING must be...

  20. 49 CFR 176.325 - Smoking or open flame and posting of warning signs.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Smoking or open flame and posting of warning signs... Smoking or open flame and posting of warning signs. (a) Smoking or the use of open flame is prohibited in... material. (b) A sign carrying the legend: FLAMMABLE VAPORS KEEP LIGHTS AND FIRE AWAY NO SMOKING must be...

  1. 49 CFR 176.325 - Smoking or open flame and posting of warning signs.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Smoking or open flame and posting of warning signs... Smoking or open flame and posting of warning signs. (a) Smoking or the use of open flame is prohibited in... material. (b) A sign carrying the legend: FLAMMABLE VAPORS KEEP LIGHTS AND FIRE AWAY NO SMOKING must be...

  2. 49 CFR 176.325 - Smoking or open flame and posting of warning signs.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Smoking or open flame and posting of warning signs... Smoking or open flame and posting of warning signs. (a) Smoking or the use of open flame is prohibited in... material. (b) A sign carrying the legend: FLAMMABLE VAPORS KEEP LIGHTS AND FIRE AWAY NO SMOKING must be...

  3. 78 FR 40195 - Proposed Information Collection; Application for a Permit To Fire More than 20 Boreholes and/or...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-03

    ... DEPARTMENT OF LABOR Mine Safety and Health Administration Proposed Information Collection..., Explosives, and Shot-Firing Units; Posting Notices of Misfires AGENCY: Mine Safety and Health Administration..., and the impact of collection requirements on respondents can be properly assessed. Currently, the Mine...

  4. 14 CFR 25.1203 - Fire detector system.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... fire zone, and in the combustion, turbine, and tailpipe sections of turbine engine installations, in... the sensor or associated wiring within a designated fire zone is severed at one point, unless the... means to warn the crew in the event of a short circuit in the sensor or associated wiring within a...

  5. Assessing Mental Models of Emergencies Through Two Knowledge Elicitation Tasks.

    PubMed

    Whitmer, Daphne E; Sims, Valerie K; Torres, Michael E

    2017-05-01

    The goals of this study were to assess the risk identification aspect of mental models using standard elicitation methods and how university campus alerts were related to these mental models. People fail to follow protective action recommendations in emergency warnings. Past research has yet to examine cognitive processes that influence emergency decision-making. Study 1 examined 2 years of emergency alerts distributed by a large southeastern university. In Study 2, participants listed emergencies in a thought-listing task. Study 3 measured participants' time to decide if a situation was an emergency. The university distributed the most alerts about an armed person, theft, and fire. In Study 2, participants most frequently listed fire, car accident, heart attack, and theft. In Study 3, participants quickly decided a bomb, murder, fire, tornado, and rape were emergencies. They most slowly decided that a suspicious package and identify theft were emergencies. Recent interaction with warnings was only somewhat related to participants' mental models of emergencies. Risk identification precedes decision-making and applying protective actions. Examining these characteristics of people's mental representations of emergencies is fundamental to further understand why some emergency warnings go ignored. Someone must believe a situation is serious to categorize it as an emergency before taking the protective action recommendations in an emergency warning. Present-day research must continue to examine the problem of people ignoring warning communication, as there are important cognitive factors that have not yet been explored until the present research.

  6. 15 CFR 946.4 - Menu of services.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE REGULATIONS OF THE NATIONAL WEATHER SERVICE MODERNIZATION OF THE NATIONAL WEATHER SERVICE § 946.4 Menu of services. The following are the basic weather...) Marine Forecasts, Statements, and Warnings (g) Hydrologic Forecasts and Warnings (h) Fire Weather...

  7. 15 CFR 946.4 - Menu of services.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE REGULATIONS OF THE NATIONAL WEATHER SERVICE MODERNIZATION OF THE NATIONAL WEATHER SERVICE § 946.4 Menu of services. The following are the basic weather...) Marine Forecasts, Statements, and Warnings (g) Hydrologic Forecasts and Warnings (h) Fire Weather...

  8. Dynamic pressure measurement of cartridge operated vole captive bolt devices.

    PubMed

    Frank, M; Philipp, K P; Franke, E; Frank, N; Bockholdt, B; Grossjohann, R; Ekkernkamp, A

    2009-01-10

    Vole captive bolt devices are powder actuated spring guns that are used as a pest control mean. After having triggered the explosion of the blank cartridge by touching a metal ring around the muzzle, the vole is killed by the massive propulsion of the gas jet. Improper use and recklessness while handling these devices may cause severe injuries with the hand of the operator at particular risk. Currently, there are no experimental investigations on the ballistic background of these devices. An experimental test set-up was designed for measurement of the firing pressure and the dynamic force of the gas jet of a vole captive bolt device. Therefore, a vole captive bolt device was prepared with a pressure take-off channel and a piezoelectric transducer for measurement of the firing pressure. For measurement of the dynamic impact force of the gas jet an annular quartz force sensor was installed on a test bench. Each three simultaneous measurements of the cartridges' firing pressure and the dynamic force of the blast wave were taken at various distances between muzzle and load washer. The maximum gas pressure in the explosion chamber was up to 1100 bar. The shot development over time showed a typical gas pressure curve. Flow velocity of the gas jet was up to 2000 m/s. The maximum impact force of the gas jet at the target showed a strong inverse ratio to the muzzle's distance and was up to 11,500 N for the contact shot distance. Energy density of the gas jet for the close contact shot was far beyond the energy density required for skin penetration. The unique design features (short tube between cartridge mouth and muzzle and narrow diameter of the muzzle) of these gadgets are responsible for the high firing pressure, velocity and force of the gas jet. These findings explain the trauma mechanics of the extensive tissue damage observed in accidental shots of these devices.

  9. Meteorological conditions affecting the Freeman Lake (Idaho) fire

    Treesearch

    George M. Jemison

    1932-01-01

    Measurements of meteorological conditions prevailing during the rapid spread of forest fires are greatly needed so that when their recurrence seems probable, fire-weather forecasters may issue warnings of the danger. Such determinations also can be used by forest protective agencies which operate meteorological stations to guide their own action in the distribution of...

  10. Strengthening community participation in reducing GHG emission from forest and peatland fire

    NASA Astrophysics Data System (ADS)

    Thoha, A. S.; Saharjo, B. H.; Boer, R.; Ardiansyah, M.

    2018-02-01

    Strengthening community participation is needed to find solutions to encourage community more participate in reducing Green House Gas (GHG) from forest and peatland fire. This research aimed to identify stakeholders that have the role in forest and peatland fire control and to formulate strengthening model of community participation through community-based early warning fire. Stakeholder mapping and action research were used to determine stakeholders that had potential influence and interest and to formulate strengthening model of community participation in reducing GHG from forest and peatland fire. There was found that position of key players in the mapping of stakeholders came from the government institution. The existence of community-based fire control group can strengthen government institution through collaborating with stakeholders having strong interest and influence. Moreover, it was found several local knowledge in Kapuas District about how communities predict drought that have potential value for developing the community-based early warning fire system. Formulated institutional model in this research also can be further developed as a model institution in the preservation of natural resources based on local knowledge. In conclusion, local knowledge and community-based fire groups can be integrated within strengthening model of community participation in reducing GHG from forest and peatland fire.

  11. National Ignition Facility Control and Information System Operational Tools

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marshall, C D; Beeler, R G; Bowers, G A

    The National Ignition Facility (NIF) in Livermore, California, is the world's highest-energy laser fusion system and one of the premier large scale scientific projects in the United States. The system is designed to setup and fire a laser shot to a fusion ignition or high energy density target at rates up to a shot every 4 hours. NIF has 192 laser beams delivering up to 1.8 MJ of energy to a {approx}2 mm target that is planned to produce >100 billion atm of pressure and temperatures of >100 million degrees centigrade. NIF is housed in a ten-story building footprint themore » size of three football fields as shown in Fig. 1. Commissioning was recently completed and NIF will be formally dedicated at Lawrence Livermore National Laboratory on May 29, 2009. The control system has 60,000 hardware controls points and employs 2 million lines of control system code. The control room has highly automated equipment setup prior to firing laser system shots. This automation has a data driven implementation that is conducive to dynamic modification and optimization depending on the shot goals defined by the end user experimenters. NIF has extensive facility machine history and infrastructure maintenance workflow tools both under development and deployed. An extensive operational tools suite has been developed to support facility operations including experimental shot setup, machine readiness, machine health and safety, and machine history. The following paragraphs discuss the current state and future upgrades to these four categories of operational tools.« less

  12. Colleges Weigh When to Alert Students of Danger

    ERIC Educational Resources Information Center

    Hoover, Eric; Lipka, Sara

    2007-01-01

    At the University of Chicago, the third Monday in November began with an hour of violence. Around 12:30 a.m., an assailant fired a shot at a staff member who was walking on the campus. At 1:15 a group of men robbed two female students on a nearby street. Just before 1:30, Amadou Cisse, a doctoral student, was shot and killed while walking to his…

  13. Spreadsheet Application Showing the Proper Elevation Angle, Points of Shot and Impact of a Projectile

    ERIC Educational Resources Information Center

    Benacka, Jan

    2015-01-01

    This paper provides the formula for the elevation angle at which a projectile has to be fired in a vacuum from a general position to hit a target at a given distance. A spreadsheet application that models the trajectory is presented, and the problem of finding the points of shot and impact of a projectile moving in a vacuum if three points of the…

  14. 30 CFR 56.4101 - Warning signs.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control... open flames shall be posted where a fire or explosion hazard exists. ...

  15. 30 CFR 57.4101 - Warning signs.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control... open flames shall be posted where a fire or explosion hazard exists. ...

  16. [The forensic medical characteristic of the factors associated with a shot from the 9.0 mm pneumatic rifle and the inflicted injuries].

    PubMed

    Raĭzberg, S A; Makarov, I Iu; Lorents, A S

    2014-01-01

    The objective of the present work was to elucidate the structural characteristics of the 9.0 mm pneumatic rifle and three regular types of the bullets differing in the head shape fired from it. Morphological features of the injuries inflicted by such bullets are described in conjunction with the peculiarities of precipitation of the shot products in their projection as the prerequisites for their objective differentiation. Results: The study allowed to reveal the composition of the gunshot residues and to determine the maximum distance of their distribution. The specific features of experimental damage inflicted by the shots from the 9.0 mm pneumatic rifle to the coarse white calico fabric targets were shown to depend on the shot range. The objective signs of the so-called "short-range" shot from the 9.0 mm pneumatic rifle were described for the first time.

  17. [Experimental effect of a shot caused by 4.5 mm cartridges fired from a Norica Dragon air-rifle and a Walther PPK/S air-pistol].

    PubMed

    Smedra-Kaźmirska, Anna; Barzdo, Maciej; Kedzierski, Maciej; Szram, Stefan; Berent, Jarosław

    2010-01-01

    In Poland, according to the Weapons and Ammunition Act" an air weapon which has kinetic energy of fired projectiles below 17 J does not require registration and can be bought even on the Internet. Sport and recreational shooting with this weapon does not have to be performed in a special shooting-range, but can be carried on in an open terrain providing "particular caution" is exercised. In this study we presented experimental effects of shooting pneumatic weapons (Norica Dragon air-rifle and Walther PPK/S air-pistol) which had kinetic energy of fired projectiles below 17 J. The aim of this study was to assess the effects of shooting the above weapons at human soft tissues and thin bones of the temple region to empirically evaluate the degree of danger to health and life, which such shots can produce. We used 20% gelatine blocks at 10 degrees C, which were the model of human soft tissues, and fresh calf scapulas, which served as the models of the temporal bone of the human cranium. Before the experiment, we had evaluated the weight of all the projectiles and their initial velocity using a chronograph. By these measures, we calculated the kinetic energy of the fired missiles. After shooting, we estimated if projectiles of different shapes shot from air weapons characterized by different kinetic energy and from different distances penetrated the gelatine blocks and if the said missiles perforated the bones. We also measured the depth of missiles penetration in the gelatine blocks.

  18. Seismic refraction profile, Kingdom of Saudi Arabia: field operations, instrumentation, and initial results

    USGS Publications Warehouse

    Blank, H. Richard; Healy, J.H.; Roller, John; Lamson, Ralph; Fisher, Fred; McClearn, Robert; Allen, Steve

    1979-01-01

    In February 1978 a seismic deep-refraction profile was recorded by the USGS along a 1000-km line across the Arabian Shield in western Saudi Arabia. The line begins in Paleozoic and Mesozoic cover rocks near Riyadh on the Arabian Platform, leads southwesterly across three major Precambrian tectonic provinces, traverses Cenozoic rocks of the coastal plain near Jizan (Tihamat Asir), and terminates at the outer edge of the Farasan Bank in the southern Red Sea. More than 500 surveyed recording sites were occupied, including 19 in the Farasan Islands. Six shot points were used--five on land, with charges placed mostly below water table in drill holes, and one at sea, with charges placed on the sea floor and fired from a ship. The total charge consumed was slightly in excess of 61 metric tons in 21 discrete firings. Seismic energy was recorded by means of a set of 100 newly developed portable seismic stations. Each station consists of a standard 2-Hz vertical geophone coupled to a self-contained analog recording instrument equipped with a magnetic-tape cassette. The stations were deployed in groups of 20 by five observer teams, each generally consisting of two scientist-technicians and a surveyor-guide. On the day prior to deployment, the instruments were calibrated and programmed for automatic operation by means of a specially designed device called a hand-held tester. At each of ten pre-selected recording time windows on a designated firing day, the instruments were programmed to turn on, stabilize, record internal calibration signals, record the seismic signals at three levels of amplification, and then deactivate. After the final window in the firing sequence, all instruments were retrieved and their data tapes removed for processing. A specially designed, field tape- dubbing system was utilized at shot point camps to organize and edit data recorded on the cassette tapes. The main functions of this system are to concatenate all data from each shot on any given day onto a single shot tape, and to provide hard copy for monitoring recorder performance so that any problems can be corrected prior to the next deployment. Composite digital record sections were produced from the dubbed tapes for each shot point by a portable processing and plotting system. The heart of this system is a DEC PDP 11VO3 computer, which controls a cassette playback unit identical to those used in the recorders and dubbers, a set of discriminators, a time-code translator, a digitizer, and a digital plotter. The system was used to maintain various informational data sets and to produce tabulations and listings of various sorts during the field operations, in addition to its main task of producing digital record sections. Two master clocks, both set to time signals broadcast by the British Broadcasting Corporation, provided absolute time for the recording operations. One was located on the ship and the other was stationed at a base camp on the mainland. The land-based master clock was used to set three additional master clocks located at the other active shot points a few days in advance of each firing, and these clocks were then used to set the internal clocks in the portable seismic stations via the hand-held tester. A master clock signal was also linked to the firing system at each shot point for determination of the absolute shot instant. It is possible to construct a generalized crustal model from examination of the six shot point composite record sections obtained in the field. Such a model rests upon a number of simplifying assumptions and will almost certainly be modified at a later stage of interpretation. The main assumptions are that the crust consists of two homogeneous isotropic layers having no velocity inversion,, that the Mohorovicic discontinuity is sharp, and that effects of surface inhomogeneities and elevation changes can be ignored. The main characteristics of the tentative model are the following: (1) The thickness of th

  19. 14 CFR 121.308 - Lavatory fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... detector system or equivalent that provides a warning light in the cockpit or provides a warning light or... comply with the smoke detector system requirements described in paragraph (a) of this section and the... detector system requirements described in paragraph (a) of this section, except that the smoke detector...

  20. 14 CFR 121.308 - Lavatory fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... detector system or equivalent that provides a warning light in the cockpit or provides a warning light or... comply with the smoke detector system requirements described in paragraph (a) of this section and the... detector system requirements described in paragraph (a) of this section, except that the smoke detector...

  1. 14 CFR 121.308 - Lavatory fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... detector system or equivalent that provides a warning light in the cockpit or provides a warning light or... comply with the smoke detector system requirements described in paragraph (a) of this section and the... detector system requirements described in paragraph (a) of this section, except that the smoke detector...

  2. 14 CFR 121.308 - Lavatory fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... detector system or equivalent that provides a warning light in the cockpit or provides a warning light or... comply with the smoke detector system requirements described in paragraph (a) of this section and the... detector system requirements described in paragraph (a) of this section, except that the smoke detector...

  3. 14 CFR 121.308 - Lavatory fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... detector system or equivalent that provides a warning light in the cockpit or provides a warning light or... comply with the smoke detector system requirements described in paragraph (a) of this section and the... detector system requirements described in paragraph (a) of this section, except that the smoke detector...

  4. Detecting the Onset of Fire in an Aircraft by Employing Correlation Spectroscopy

    NASA Technical Reports Server (NTRS)

    Goswami, Kisholoy; Saxena, Indu; Egalon, Claudio; Mendoza, Edgar; Lieberman, Robert; Piltch, Nancy D.

    1999-01-01

    The cause of aircraft fire and locations of the fires are numerous. Worldwide, numerous in-flight fires have been passenger initiated, the prime location being the lavatory areas. Most in-flight fires in commercial carriers are of electrical origin and cigarettes. A cargo bay fire can be caused by a variety of reasons. The sheer number of different types of cargo makes it difficult to identify the origin, especially when the fire reaches the catastrophic level. The damage can be minimized, and fire can be suppressed effectively if a warning system for the onset of fire is available for onboard monitoring.

  5. 29 CFR 1910.37 - Maintenance, safeguards, and operational features for exit routes.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...., sprinkler systems, alarm systems, fire doors, exit lighting) must be in proper working order at all times... maintain an operable employee alarm system that has a distinctive signal to warn employees of fire or other...” not less than three-fourths of an inch (1.9 cm) wide. (c) The fire retardant properties of paints or...

  6. 29 CFR 1910.37 - Maintenance, safeguards, and operational features for exit routes.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...., sprinkler systems, alarm systems, fire doors, exit lighting) must be in proper working order at all times... maintain an operable employee alarm system that has a distinctive signal to warn employees of fire or other...” not less than three-fourths of an inch (1.9 cm) wide. (c) The fire retardant properties of paints or...

  7. 29 CFR 1910.37 - Maintenance, safeguards, and operational features for exit routes.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...., sprinkler systems, alarm systems, fire doors, exit lighting) must be in proper working order at all times... maintain an operable employee alarm system that has a distinctive signal to warn employees of fire or other...” not less than three-fourths of an inch (1.9 cm) wide. (c) The fire retardant properties of paints or...

  8. 29 CFR 1910.37 - Maintenance, safeguards, and operational features for exit routes.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...., sprinkler systems, alarm systems, fire doors, exit lighting) must be in proper working order at all times... maintain an operable employee alarm system that has a distinctive signal to warn employees of fire or other...” not less than three-fourths of an inch (1.9 cm) wide. (c) The fire retardant properties of paints or...

  9. Warning signals for eruptive events in spreading fires.

    PubMed

    Fox, Jerome M; Whitesides, George M

    2015-02-24

    Spreading fires are noisy (and potentially chaotic) systems in which transitions in dynamics are notoriously difficult to predict. As flames move through spatially heterogeneous environments, sudden shifts in temperature, wind, or topography can generate combustion instabilities, or trigger self-stabilizing feedback loops, that dramatically amplify the intensities and rates with which fires propagate. Such transitions are rarely captured by predictive models of fire behavior and, thus, complicate efforts in fire suppression. This paper describes a simple, remarkably instructive physical model for examining the eruption of small flames into intense, rapidly moving flames stabilized by feedback between wind and fire (i.e., "wind-fire coupling"-a mechanism of feedback particularly relevant to forest fires), and it presents evidence that characteristic patterns in the dynamics of spreading flames indicate when such transitions are likely to occur. In this model system, flames propagate along strips of nitrocellulose with one of two possible modes of propagation: a slow, structured mode, and a fast, unstructured mode sustained by wind-fire coupling. Experimental examination of patterns in dynamics that emerge near bifurcation points suggests that symptoms of critical slowing down (i.e., the slowed recovery of the system from perturbations as it approaches tipping points) warn of impending transitions to the unstructured mode. Findings suggest that slowing responses of spreading flames to sudden changes in environment (e.g., wind, terrain, temperature) may anticipate the onset of intense, feedback-stabilized modes of propagation (e.g., "blowup fires" in forests).

  10. Design of Explosion Blast Containment Vessels for Explosive Ordnance Disposal Units

    DTIC Science & Technology

    1975-06-01

    gages installed on Vessels 1 and 3 were Type EP-08-250BF-350. ,hec: gages, which are special , annealed constantan foil, have a quoted strain range of...either 32 or 24 Vdc from automotive-type wet cell batteries, although large dry cells may be used with slightly reduced stability. The bridge output is...RST-CYCLE VESEL RESPONSE I. -- ~-~- --. - - ,--~ -- --- -~ - - -- ~ ~ -- 72 TABLE 10. DESCRIPTION OF BLACK POWDER SHOTS FIRED IN 3.0-FT VESSEL Shot

  11. 30 CFR 56.4330 - Firefighting, evacuation, and rescue procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control Firefighting Procedures/alarms/drills § 56.4330 Firefighting, evacuation... organizations. (b) Fire alarm procedures or systems shall be established to pomptly warn every person who could...

  12. 30 CFR 57.4363 - Underground evacuation instruction.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Section 57.4363 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire... and evacuation plans and procedures and fire warning signals in effect at the mine. (b) Whenever a...

  13. Fire Ant Allergy

    MedlinePlus

    ... Menu Search Main navigation Skip to content Conditions & Treatments Allergies Asthma Primary Immunodeficiency Disease Related Conditions Drug Guide ... your condition and determine the best form of treatment. Allergy shots (immunotherapy) may be effective long-term treatment ...

  14. Warning signals for eruptive events in spreading fires

    PubMed Central

    Fox, Jerome M.; Whitesides, George M.

    2015-01-01

    Spreading fires are noisy (and potentially chaotic) systems in which transitions in dynamics are notoriously difficult to predict. As flames move through spatially heterogeneous environments, sudden shifts in temperature, wind, or topography can generate combustion instabilities, or trigger self-stabilizing feedback loops, that dramatically amplify the intensities and rates with which fires propagate. Such transitions are rarely captured by predictive models of fire behavior and, thus, complicate efforts in fire suppression. This paper describes a simple, remarkably instructive physical model for examining the eruption of small flames into intense, rapidly moving flames stabilized by feedback between wind and fire (i.e., “wind–fire coupling”—a mechanism of feedback particularly relevant to forest fires), and it presents evidence that characteristic patterns in the dynamics of spreading flames indicate when such transitions are likely to occur. In this model system, flames propagate along strips of nitrocellulose with one of two possible modes of propagation: a slow, structured mode, and a fast, unstructured mode sustained by wind–fire coupling. Experimental examination of patterns in dynamics that emerge near bifurcation points suggests that symptoms of critical slowing down (i.e., the slowed recovery of the system from perturbations as it approaches tipping points) warn of impending transitions to the unstructured mode. Findings suggest that slowing responses of spreading flames to sudden changes in environment (e.g., wind, terrain, temperature) may anticipate the onset of intense, feedback-stabilized modes of propagation (e.g., “blowup fires” in forests). PMID:25675491

  15. 29 CFR 1926.912 - Underwater blasting.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Underwater blasting. (a) A blaster shall conduct all blasting operations, and no shot shall be fired without... herein on handling and storing explosives. (h) When more than one charge is placed under water, a float...

  16. 29 CFR 1926.912 - Underwater blasting.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Underwater blasting. (a) A blaster shall conduct all blasting operations, and no shot shall be fired without... herein on handling and storing explosives. (h) When more than one charge is placed under water, a float...

  17. 29 CFR 1926.912 - Underwater blasting.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Underwater blasting. (a) A blaster shall conduct all blasting operations, and no shot shall be fired without... herein on handling and storing explosives. (h) When more than one charge is placed under water, a float...

  18. 29 CFR 1926.912 - Underwater blasting.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Underwater blasting. (a) A blaster shall conduct all blasting operations, and no shot shall be fired without... herein on handling and storing explosives. (h) When more than one charge is placed under water, a float...

  19. 29 CFR 1926.912 - Underwater blasting.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Underwater blasting. (a) A blaster shall conduct all blasting operations, and no shot shall be fired without... herein on handling and storing explosives. (h) When more than one charge is placed under water, a float...

  20. Wounds caused by contact with muzzle-lift relief ports (Mag-Na-Port).

    PubMed

    Rogers, D R; Shem, R J

    1992-12-01

    Fan-shaped stippled burns were produced on the skin when a revolver whose barrel had been modified by the Mag-Na-Port process was fired twice with the side of the muzzle in contact. A grazing wound was produced by one bullet, and an oblique entry was produced by the other. The characteristics of Mag-Na-Port wounds and test shots are described, and these are compared with test shots from two other higher power revolvers.

  1. 30 CFR 57.4363 - Underground evacuation instruction.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and evacuation plans and procedures and fire warning signals in effect at the mine. (b) Whenever a change is made in escape and evacuation plans and procedures for any area of the mine, all persons... NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire...

  2. 30 CFR 57.4363 - Underground evacuation instruction.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and evacuation plans and procedures and fire warning signals in effect at the mine. (b) Whenever a change is made in escape and evacuation plans and procedures for any area of the mine, all persons... NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire...

  3. 30 CFR 57.4363 - Underground evacuation instruction.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... and evacuation plans and procedures and fire warning signals in effect at the mine. (b) Whenever a change is made in escape and evacuation plans and procedures for any area of the mine, all persons... NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire...

  4. Spent shot availability and ingestion on areas managed for mourning doves

    USGS Publications Warehouse

    Schulz, J.H.; Millspaugh, J.J.; Washburn, B.E.; Wester, G.R.; Lanigan, J. T.; Franson, J.C.

    2002-01-01

    Mourning dove (Zenaida macroura) hunting is becoming increasingly popular, especially in managed shooting fields. Given the possible increase in the availability of lead (Pb) shot on these areas, our objective was to estimate availability and ingestion of spent shot at the Eagle Bluffs Conservation Area (EBCA, hunted with nontoxic shot) and the James A. Reed Memorial Wildlife Area (JARWA, hunted with Pb shot) in Missouri. During 1998, we collected soil samples one or 2 weeks prior to the hunting season (prehunt) and after 4 days of dove hunting (posthunt). We also collected information on number of doves harvested, number of shots fired, shotgun gauge, and shotshell size used. Dove carcasses were collected on both areas during 1998-99. At EBCA, 60 hunters deposited an estimated 64,775 pellets/ha of nontoxic shot on or around the managed field. At JARWA, approximately 1,086,275 pellets/ha of Pb shot were deposited by 728 hunters. Our posthunt estimates of spent-shot availability from soil sampling were 0 pellets/ha for EBCA and 6,342 pellets/ha for JARWA. Our findings suggest that existing soil sampling protocols may not provide accurate estimates of spent-shot availability in managed dove shooting fields. During 1998-99, 15 of 310 (4.8%) mourning doves collected from EBCA had ingested nontoxic shot. Of those doves, 6 (40.0%) contained a?Y7 shot pellets. In comparison, only 2 of 574 (0.3%) doves collected from JARWA had ingested Pb shot. Because a greater proportion of doves ingested multiple steel pellets compared to Pb pellets, we suggest that doves feeding in fields hunted with Pb shot may succumb to acute Pb toxicosis and thus become unavailable to harvest, resulting in an underestimate of ingestion rates. Although further research is needed to test this hypothesis, our findings may partially explain why previous studies have shown few doves with ingested Pb shot despite their feeding on areas with high Pb shot availability.

  5. Hybrid neural network for density limit disruption prediction and avoidance on J-TEXT tokamak

    NASA Astrophysics Data System (ADS)

    Zheng, W.; Hu, F. R.; Zhang, M.; Chen, Z. Y.; Zhao, X. Q.; Wang, X. L.; Shi, P.; Zhang, X. L.; Zhang, X. Q.; Zhou, Y. N.; Wei, Y. N.; Pan, Y.; J-TEXT team

    2018-05-01

    Increasing the plasma density is one of the key methods in achieving an efficient fusion reaction. High-density operation is one of the hot topics in tokamak plasmas. Density limit disruptions remain an important issue for safe operation. An effective density limit disruption prediction and avoidance system is the key to avoid density limit disruptions for long pulse steady state operations. An artificial neural network has been developed for the prediction of density limit disruptions on the J-TEXT tokamak. The neural network has been improved from a simple multi-layer design to a hybrid two-stage structure. The first stage is a custom network which uses time series diagnostics as inputs to predict plasma density, and the second stage is a three-layer feedforward neural network to predict the probability of density limit disruptions. It is found that hybrid neural network structure, combined with radiation profile information as an input can significantly improve the prediction performance, especially the average warning time ({{T}warn} ). In particular, the {{T}warn} is eight times better than that in previous work (Wang et al 2016 Plasma Phys. Control. Fusion 58 055014) (from 5 ms to 40 ms). The success rate for density limit disruptive shots is above 90%, while, the false alarm rate for other shots is below 10%. Based on the density limit disruption prediction system and the real-time density feedback control system, the on-line density limit disruption avoidance system has been implemented on the J-TEXT tokamak.

  6. The Military’s Role in Domestic Terrorism

    DTIC Science & Technology

    2007-12-01

    Aperture Radar (SLAR) technology to scout rural countryside where the FLQ was known to have training camps and safe houses.75 The ability to...native lands and redistributed them to mostly Protestant English and Scottish settlers. This led to two bloody sectarian conflicts, the Irish...sake, you could hear their CO bellowing at them to cease firing, and only to fire aimed shots at actual targets.129 British peacekeeping procedures

  7. Reality-based practice under pressure improves handgun shooting performance of police officers.

    PubMed

    Oudejans, R R D

    2008-03-01

    The current study examined whether reality-based practice under pressure may help in preventing degradation of handgun shooting performance under pressure for police officers. Using a pre-post-test design, one group of nine police officers practised handgun shooting under pressure evoked by an opponent who also fired back using marking (coloured soap) cartridges. The control group (n = 8) practised handgun shooting on standard cardboard targets instead of real opponents. Within a fortnight after the pre-test, both groups received three training sessions of 1 h, in which each person fired a total of 72 rounds. During the pre- and post test each participant took 30 shots without pressure (cardboard targets) and 30 shots under additional pressure (with an opponent firing back). While during the pre-test both groups performed worse in front of an opponent firing back compared to the cardboard targets, after the training sessions shooting performance of the experimental group no longer deteriorated with an opponent while performance of the control group was equally harmed as during the pre-test. These results indicate that training exercises involving increased pressure can acclimatize shooting performance of ordinary police officers to those situations with elevated pressure that they may encounter during their police work.

  8. Warning signals for eruptive events in spreading fires

    DOE PAGES

    Fox, Jerome M.; Whitesides, George M.

    2015-02-09

    Spreading fires are noisy (and potentially chaotic) systems in which transitions in dynamics are notoriously difficult to predict. As flames move through spatially heterogeneous environments, sudden shifts in temperature, wind, or topography can generate combustion instabilities, or trigger self-stabilizing feedback loops, that dramatically amplify the intensities and rates with which fires propagate. Such transitions are rarely captured by predictive models of fire behavior and, thus, complicate efforts in fire suppression. This study describes a simple, remarkably instructive physical model for examining the eruption of small flames into intense, rapidly moving flames stabilized by feedback between wind and fire (i.e., “wind–firemore » coupling”—a mechanism of feedback particularly relevant to forest fires), and it presents evidence that characteristic patterns in the dynamics of spreading flames indicate when such transitions are likely to occur. Here, in this model system, flames propagate along strips of nitrocellulose with one of two possible modes of propagation: a slow, structured mode, and a fast, unstructured mode sustained by wind–fire coupling. Experimental examination of patterns in dynamics that emerge near bifurcation points suggests that symptoms of critical slowing down (i.e., the slowed recovery of the system from perturbations as it approaches tipping points) warn of impending transitions to the unstructured mode. Lastly, findings suggest that slowing responses of spreading flames to sudden changes in environment (e.g., wind, terrain, temperature) may anticipate the onset of intense, feedback-stabilized modes of propagation (e.g., “blowup fires” in forests).« less

  9. Warning signals for eruptive events in spreading fires

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fox, Jerome M.; Whitesides, George M.

    Spreading fires are noisy (and potentially chaotic) systems in which transitions in dynamics are notoriously difficult to predict. As flames move through spatially heterogeneous environments, sudden shifts in temperature, wind, or topography can generate combustion instabilities, or trigger self-stabilizing feedback loops, that dramatically amplify the intensities and rates with which fires propagate. Such transitions are rarely captured by predictive models of fire behavior and, thus, complicate efforts in fire suppression. This study describes a simple, remarkably instructive physical model for examining the eruption of small flames into intense, rapidly moving flames stabilized by feedback between wind and fire (i.e., “wind–firemore » coupling”—a mechanism of feedback particularly relevant to forest fires), and it presents evidence that characteristic patterns in the dynamics of spreading flames indicate when such transitions are likely to occur. Here, in this model system, flames propagate along strips of nitrocellulose with one of two possible modes of propagation: a slow, structured mode, and a fast, unstructured mode sustained by wind–fire coupling. Experimental examination of patterns in dynamics that emerge near bifurcation points suggests that symptoms of critical slowing down (i.e., the slowed recovery of the system from perturbations as it approaches tipping points) warn of impending transitions to the unstructured mode. Lastly, findings suggest that slowing responses of spreading flames to sudden changes in environment (e.g., wind, terrain, temperature) may anticipate the onset of intense, feedback-stabilized modes of propagation (e.g., “blowup fires” in forests).« less

  10. Forest Fire Management: A Comprehensive And Operational Approach

    NASA Astrophysics Data System (ADS)

    Fabrizi, Roberto; Perez, Bruno; Gomez, Antonio

    2013-12-01

    Remote sensing plays an important role in obtaining rapid and complete information on the occurrence and evolution in space and time of forest fires. In this paper, we present a comprehensive study of fire events through Earth Observation data for early warning, crisis monitoring and post-event damage assessment or a synthesis of the fire event, both in a wide spatial range (local to regional) and temporal scale (short to long term). The fire products are stored and distributed by means of a WebGIS and a Geoportal with additional auxiliary geospatial data. These products allow fire managers to perform analysis and decision making in a more comprehensive manner.

  11. 46 CFR 15.855 - Cabin watchmen and fire patrolmen.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... of an uninspected passenger vessel not more than 300 GRT may substitute the use of fire detectors, heat detectors, smoke detectors, and high-water alarms with audible- and visual-warning indicators, in... detectors are located in each space containing machinery or fuel tanks per § 181.400(c) of this chapter. (2...

  12. 78 FR 67197 - Agency Information Collection Activities; Submission for OMB Review; Comment Request; Application...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-08

    ... a permit to use nonpermissible explosives and/or shot-firing units in the blasting of rock while... appropriate automated, electronic, mechanical, or other technological collection techniques or other forms of...

  13. Improved multiple-shot gun for use as a combustion stability rating device

    NASA Technical Reports Server (NTRS)

    Sokolowski, D. E.

    1973-01-01

    A program was conducted to develop and experimentally evaluate an improved version of a modified machine gun for use as a device for rating the relative combustion stability of various rocket combustors. Following the results of a previous study involving a caliber .30 machine gun, a caliber .50 machine gun was modified in order to extend the charge-size range of the device. Nitrocellulose charge sizes ranging from 1.004 to 9.720 grams were fired at rates up to four shots per second. Shock pressures up to 25,512 kN/sq m were measured near the end of a shortened gun barrel. A minimal resistance type of check valve permitted the gun to fire into pressurized regions; back pressures up to 3448 kN/sq m abs were tested. The final modified assembly was evaluated during combustion stability tests on rocket combustors burning a FLOX-methane propellant combination.

  14. The effect of range and ammunition type on fracture patterns in porcine postcranial flat bones.

    PubMed

    Fragkouli, Kleio; Al Hakeem, Eyad; Bulut, Ozgur; Simmons, Tal

    2018-01-01

    Pig half-carcasses were shot in scapulae, ribs and mandibles with either 0.243 hunting rifle using high velocity expanding ammunition (N = 30) or AK47 using full metal jacketed (FMJ) ammunition (N = 12) from a range of either 5 or 20 m. Fracture patterns related to distance of fire and ammunition type were compared on de-fleshed, macerated, and reconstructed bones. For expanding ammunition, location of fracture on ribs affected the resulting pattern. Scapulae shot from 5 m presented a comminuted pattern different from those shot from 20 m. Mandibles shot from 20 m showed a characteristic radiating pattern at entrance with the opposite ramus un-fractured; those shot from 5 m exhibited fractures to both rami. Using decision tree analysis provided accuracies of 93.8% for scapulae and 87.5% for mandibles. For FMJ, no distance dependent fracture differences were apparent in any bone. Decision tree analysis facilitated the interpretation of fracture patterns caused by projectile trauma. Copyright © 2017. Published by Elsevier Ltd.

  15. [Alteration of textilfibres by explosion gases expelled distant from the muzzle (author's transl)].

    PubMed

    Bonte, W; Kijewski, H

    1976-03-24

    This paper presents the reconstruction of an unusual case of suicide. After raiding a branch-bank a robber fled shooting with his Sauer-Western revolver caliber .44 magnum at the pursuing policemen and succeeded in wrestling a pistol Walther caliber 7,65 mm from them. Under the fire of sub-machine guns he destroyed himself by a shot to the neck. Our investigations concerned a textile damage at the front of the sweater of the deceased surrounded by primer residue, showing characteristics of a close-up shot. The damage was identified as effect of explosion gases exhausting far-off the muzzle. The distance between this injury and the bullet hole corresponded with the length of the barrel of the Sauer-Western revolver and could be used for identification; it confirmed the diagnosis of a close-up shot at the neck, too. Collateral experiments with shots from distant ranges developed spadiceous melt figures of textile fibers around the bullet hole, the appearance of which is considered proof for a close-up shot commonly.

  16. An unusual characteristic “flower-like” pattern: flash suppressor burns

    PubMed Central

    Gurcan, Altun

    2012-01-01

    The case on contact shots from firearms with a flash suppressor is rare. When a rifle fitted with a flash suppressor is fired, the emerging soot-laden gas in the barrel escapes from the slits of the flash suppressor. If the shot is contact or near contact, the flash suppressor will produce a characteristic “flower-like” pattern of seared, blackened zones around the entrance. This paper presents the injury pattern of the flash suppressor in a 29-year-old man who committed suicide with a G3 automatic infantry rifle. PMID:23935280

  17. An unusual characteristic "flower-like" pattern: flash suppressor burns.

    PubMed

    Gurcan, Altun

    2012-04-01

    The case on contact shots from firearms with a flash suppressor is rare. When a rifle fitted with a flash suppressor is fired, the emerging soot-laden gas in the barrel escapes from the slits of the flash suppressor. If the shot is contact or near contact, the flash suppressor will produce a characteristic "flower-like" pattern of seared, blackened zones around the entrance. This paper presents the injury pattern of the flash suppressor in a 29-year-old man who committed suicide with a G3 automatic infantry rifle.

  18. Investigation of the Conjugate Heat and Mass Transfer at Ignition and Subsequent Nonstationary Erosion Combustion of Powders Under Conditions Close to Those of Firing a Shot

    NASA Astrophysics Data System (ADS)

    Rusyak, I. G.; Lipanov, A. M.

    2016-11-01

    The laws of combustion of powders under conditions close to those of firing an artillery shot have been investigated. A solid-state local heat ignition model was used, and the process of powder combustion was simulated on the basis of the notions of the Belyaev-Zel'dovich thermal combustion theory. The complete formulation of the combustion problem includes the nonstationary processes of heat propagation and chemical transformation in the k-phase, as well as the quasi-stationary processes in the chemically reacting two-stage turbulent boundary layer near the combustion surface related to the characteristics of the averaged nonstationary flow by the boundary conditions at the outer boundary of the boundary layer. The features of the joint solution of the equations of the thermal combustion theory and the equations of internal ballistics have been analyzed. The questions on the convergence of the conjugate problem have been considered. The influence of various factors on the rate of combustion of powder has been investigated. The investigations conducted enabled us to formulate an approximate method for calculating the nonstationary and erosion rates of combustion of artillery powders at a shot on the basis of the Lenouard-Robillard-Karakozov approach.

  19. Cannon Fire Soon to Accompany Bugle Call at Fort Detrick | Poster

    Cancer.gov

    Beginning June 14, the familiar bugle calls at Fort Detrick will be joined by a special percussion instrument: a cannon. A single cannon shot will be fired on the first note of “Reveille,” which signals the start of each day and is accompanied by the raising of the American flag. “Reveille” sounds at 6:30 a.m. At 5 p.m., Fort Detrick plays “Retreat,” which alerts the post that

  20. Sensor and information fusion for improved hostile fire situational awareness

    NASA Astrophysics Data System (ADS)

    Scanlon, Michael V.; Ludwig, William D.

    2010-04-01

    A research-oriented Army Technology Objective (ATO) named Sensor and Information Fusion for Improved Hostile Fire Situational Awareness uniquely focuses on the underpinning technologies to detect and defeat any hostile threat; before, during, and after its occurrence. This is a joint effort led by the Army Research Laboratory, with the Armaments and the Communications and Electronics Research, Development, and Engineering Centers (CERDEC and ARDEC) partners. It addresses distributed sensor fusion and collaborative situational awareness enhancements, focusing on the underpinning technologies to detect/identify potential hostile shooters prior to firing a shot and to detect/classify/locate the firing point of hostile small arms, mortars, rockets, RPGs, and missiles after the first shot. A field experiment conducted addressed not only diverse modality sensor performance and sensor fusion benefits, but gathered useful data to develop and demonstrate the ad hoc networking and dissemination of relevant data and actionable intelligence. Represented at this field experiment were various sensor platforms such as UGS, soldier-worn, manned ground vehicles, UGVs, UAVs, and helicopters. This ATO continues to evaluate applicable technologies to include retro-reflection, UV, IR, visible, glint, LADAR, radar, acoustic, seismic, E-field, narrow-band emission and image processing techniques to detect the threats with very high confidence. Networked fusion of multi-modal data will reduce false alarms and improve actionable intelligence by distributing grid coordinates, detection report features, and imagery of threats.

  1. Breaking bad news: Effects of forecasting diagnosis and framing prognosis.

    PubMed

    Porensky, Emily K; Carpenter, Brian D

    2016-01-01

    Research to support guidelines for breaking bad news is lacking. This study used an experimental paradigm to test two communication strategies, forecasting bad news and framing prognosis, in the context of cancer. In a 2×2 design, 128 participants received bad news in a hypothetical consultation. A videotaped physician presented diagnostic and prognostic information, varying warning (warning shot vs. no warning), and framing (positive vs. negative). Effects on psychological distress, recall accuracy, and subjective interpretations of the news were assessed. Warning was not associated with lower psychological distress or improved recall. Individuals who heard a positively-framed prognosis had significantly less psychological distress, rated their prognosis better, and were more hopeful than those who heard a negatively-framed prognosis. However, they also showed a trend toward reduced accuracy in recalling prognostic statistics. Results contribute to a growing body of literature exploring optimal approaches for communicating bad news in health care. Although research in clinical settings is needed to bolster results, findings suggest that when providers use positive framing to reduce distress about prognosis, they should also consider ways to overcome potential reductions in recall accuracy, such as repeating statistical information or supplementing with written information. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. 33 CFR 334.420 - Pamlico Sound and adjacent waters, N.C.; danger zones for Marine Corps operations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Bombing and rocket firing area in Pamlico Sound in vicinity of Brant Island—(1) The area. The waters.... Upon being so warned vessels working in the area shall leave the area immediately. (b) Bombing, rocket... regulations. (i) The area described in paragraph (b)(1) of this section will be used as bombing, rocket firing...

  3. 33 CFR 334.420 - Pamlico Sound and adjacent waters, N.C.; danger zones for Marine Corps operations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Bombing and rocket firing area in Pamlico Sound in vicinity of Brant Island—(1) The area. The waters.... Upon being so warned vessels working in the area shall leave the area immediately. (b) Bombing, rocket... regulations. (i) The area described in paragraph (b)(1) of this section will be used as bombing, rocket firing...

  4. 33 CFR 334.420 - Pamlico Sound and adjacent waters, N.C.; danger zones for Marine Corps operations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Bombing and rocket firing area in Pamlico Sound in vicinity of Brant Island—(1) The area. The waters.... Upon being so warned vessels working in the area shall leave the area immediately. (b) Bombing, rocket... regulations. (i) The area described in paragraph (b)(1) of this section will be used as bombing, rocket firing...

  5. 33 CFR 334.420 - Pamlico Sound and adjacent waters, N.C.; danger zones for Marine Corps operations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Bombing and rocket firing area in Pamlico Sound in vicinity of Brant Island—(1) The area. The waters.... Upon being so warned vessels working in the area shall leave the area immediately. (b) Bombing, rocket... bombing, rocket firing, and strafing areas. Live and dummy ammunition will be used. The area shall be...

  6. 33 CFR 334.420 - Pamlico Sound and adjacent waters, N.C.; danger zones for Marine Corps operations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Bombing and rocket firing area in Pamlico Sound in vicinity of Brant Island—(1) The area. The waters.... Upon being so warned vessels working in the area shall leave the area immediately. (b) Bombing, rocket... regulations. (i) The area described in paragraph (b)(1) of this section will be used as bombing, rocket firing...

  7. Timing system for firing widely spaced test nuclear detonations

    NASA Technical Reports Server (NTRS)

    Partridge, Ralph E.

    1992-01-01

    The national weapons design laboratories (Los Alamos National Laboratory and Lawrence Livermore National Laboratory) test fire nuclear devices at the Nevada Test Site (NTS), which is spread over an area of over 1200 square miles. On each test there are hundreds of high time resolution recordings made of nuclear output waveforms and other phenomena. In order to synchronize these recordings with each other, with the nuclear device, and with offsite recordings, there is a requirement that the permanent command center and the outlying temporary firing sites be time tied to each other and to UTC to permit firing the shot at a predetermined time with an accuracy of about a microsecond. Various aspects of the test setup and timing system are discussed.

  8. Forensic value of gunpowder tattooing in identification of multiple entrance wounds from one bullet.

    PubMed

    Tokdemir, Mehmet; Kafadar, Huseyin; Turkoglu, Abdurrahim; Bork, Turgay

    2007-05-01

    Multiple entrance gunshot wounds can give useful information in forensic evaluation of deaths from homicide and suicide. Although the presence of multiple entrance gunshot wounds does not absolutely exclude the possibility of suicide, they are important to the forensic investigators and pathologists in cases of assault, attempted homicide and suicide as they provide important clues for determination of number of shots fired and direction of firing. We present a case of 16 years of young woman who was shot to death by her husband. External examination revealed an entrance wound with semi-lunar shot residue at the dorsal side of her left hand at 5th metacarpus, and exit wound on the hypothenar muscle. There was also a second wound entrance located on her left zygoma. Direction of the bullet was downward traveling from left-to-right. Initially it was thought that there were two close shots, but when her left hand was placed over the malar area her face, it was determined that the gunshot powder tattoos were completing the nature of a single shot from a close distance. Crime scene investigation revealed only one cartridge casing. The autopsy and radiography findings showed that the bullet was entered from dorsal site of the left hand exiting from the palm and re-entering from the zygomatic region, hit the base of the skull, and remained in the soft tissue of the right mandible after passing the soft palate. The bullet was caused an incomplete laceration of the right internal arteria carotid and she died of internal and external bleeding. Detailed investigation of gunshot residues can provide important information for clarification of close distance gunshot wounding. We present this case due to its interesting nature, and to highlight the importance of detailed investigation of the gun powder residues in cases with multiple entry wounds.

  9. Wounds due to a modified shot gun (home-made): a case report.

    PubMed

    Palimar, Vikram; Nayak, Vinod C; Arun, M; Kumar, Pradeep G; Bhagavath, Prashantha

    2010-05-01

    In a case of firearm fatality, the autopsy surgeon is required to opine as to the range of fire in addition to the cause of death which will help in reconstruction of the events. Problems may arise in estimating the range of fire based on wound ballistics when there is an alteration or modification in the internal ballistics. We encountered such a case in the department of Forensic Medicine, Kasturba Medical College, Manipal, which is discussed. Copyright (c) 2010. Published by Elsevier Ltd.

  10. The Nation That Cried Lone Wolf: A Data-Driven Analysis of Individual Terrorists in the United States Since 9/11

    DTIC Science & Technology

    2012-03-01

    the “ Underwear Bomber.” He is not classified as a lone-wolf terrorist, although he did operationalize his attack as a lone individual. Abdulmutallab...commencing the attacks. 4. July 2002—Hesham Mohamed Hadayet Hesham Mohamed Hadayet opened fire in Los Angeles International Airport on July 4, 2002...killed Hadayet at the scene. 76 5. October 2002—Steve Kim Postal worker Steve Kim fired seven shots at the United Nations to physically protest

  11. Forecasting Fire Season Severity in South America Using Sea Surface Temperature Anomalies

    NASA Technical Reports Server (NTRS)

    Chen, Yang; Randerson, James T.; Morton, Douglas C.; DeFries, Ruth S.; Collatz, G. James; Kasibhatla, Prasad S.; Giglio, Louis; Jin, Yufang; Marlier, Miriam E.

    2011-01-01

    Fires in South America cause forest degradation and contribute to carbon emissions associated with land use change. We investigated the relationship between year-to-year changes in fire activity in South America and sea surface temperatures. We found that the Oceanic Ni o Index was correlated with interannual fire activity in the eastern Amazon, whereas the Atlantic Multidecadal Oscillation index was more closely linked with fires in the southern and southwestern Amazon. Combining these two climate indices, we developed an empirical model to forecast regional fire season severity with lead times of 3 to 5 months. Our approach may contribute to the development of an early warning system for anticipating the vulnerability of Amazon forests to fires, thus enabling more effective management with benefits for climate and air quality.

  12. The Application of LANDSAT Multi-Temporal Thermal Infrared Data to Identify Coal Fire in the Khanh Hoa Coal Mine, Thai Nguyen province, Vietnam

    NASA Astrophysics Data System (ADS)

    Trinh, Le Hung; Zablotskii, V. R.

    2017-12-01

    The Khanh Hoa coal mine is a surface coal mine in the Thai Nguyen province, which is one of the largest deposits of coal in the Vietnam. Numerous reasons such as improper mining techniques and policy, as well as unauthorized mining caused surface and subsurface coal fire in this area. Coal fire is a dangerous phenomenon which affects the environment seriously by releasing toxic fumes which causes forest fires, and subsidence of infrastructure surface. This article presents study on the application of LANDSAT multi-temporal thermal infrared images, which help to detect coal fire. The results obtained in this study can be used to monitor fire zones so as to give warnings and solutions to prevent coal fire.

  13. Target for 100,000th Laser Shot by Curiosity on Mars

    NASA Image and Video Library

    2013-12-05

    Since landing on Mars in August 2012, NASA Curiosity Mars rover has fired the laser on its Chemistry and Camera ChemCam instrument more than 100,000 times at rock and soil targets up to about 23 feet 7 meters away.

  14. 3 CFR 8385 - Proclamation 8385 of May 22, 2009. Prayer for Peace, Memorial Day, 2009

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Nation’s safety before their own for generations. From the first shots fired at Lexington and Concord to..., their families, and all those who have lost loved ones in the defense of our freedom and safety. Today...

  15. National Weather Service

    MedlinePlus

    ... Data SAFETY Floods Tsunami Beach Hazards Wildfire Cold Tornadoes Fog Air Quality Heat Hurricanes Lightning Safe Boating ... Winter Weather Forecasts River Flooding Latest Warnings Thunderstorm/Tornado Outlook Hurricanes Fire Weather Outlooks UV Alerts Drought ...

  16. Onsite Portable Alarm System - Its Merit and Application

    NASA Astrophysics Data System (ADS)

    Saita, J.; Sato, T.; Nakamura, Y.

    2007-12-01

    Recently an existence of the earthquake early warning system (EEWS) becomes popular. In general, the EEWS will be installed in a fixed observation site and it may consist of several separated components such as a sensing portion, A/D converter, an information processing potion and so on. The processed information for warning may be transmitted to network via fixed communication line, and therefore this kind of alarm system is called as Network Alarm System. On the other hand, after the severe earthquake damage, it is very important to save the disaster victims immediately. These rescue staffs are also under the risk of aftershocks and need a local alarm not depending on the network, so this kind of alarm can be called as Onsite Alarm. But the common early warning system is too complex to set onsite temporary, and even if possible to install, the alarm is too late to receive at the epicentral area. However, the new generation earthquake early warning system FREQL can issue the P wave alarm by minimum 0.2 seconds after P wave detection. And FREQL is characterized as the unique all-in-one seismometer with power unit. At the time of the 2004 Niigata-Ken-Chuetsu earthquake, a land slide attacked a car just passing. A hyper rescue team of Tokyo Fire Department pulled the survivor, one baby, from the land slide area. During their activity the rescue team was exposed to the risk of secondary hazards caused by the aftershocks. It was clear that it is necessary to use a portable warning system to issue the onsite P wave alarm. Because FREQL was originally developed as portable equipment, Tokyo Fire Department asked us to modify it to the portable equipment with the loud sound and the light signal. In this moment, this portable FREQL has equipped in nation wide. When the hyper rescue team of Tokyo Fire Department was sent to Pakistan as a task force for rescue work of the 2005 Pakistan earthquake, the portable FREQL was used as important onsite portable warning system and P wave alarms was actually issued by three times during the rescue work. Although this is one example for the actual application of portable onsite alarm, it is possible to apply the other field as the construction field. In this presentation, Portable Onsite Alarm is discussed from views of its necessity and application.

  17. 50 CFR 32.20 - Alabama.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...). 5. We allow shotguns with #4 shot or smaller, rifles firing .22 caliber rimfire ammunition, or... State-approved hunter education course. One adult may supervise no more than two youths. 7. We prohibit.... One adult may supervise no more than one youth. 8. We prohibit participation in organized drives. D...

  18. 50 CFR 32.20 - Alabama.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...). 5. We allow shotguns with #4 shot or smaller, rifles firing .22 caliber rimfire ammunition, or... State-approved hunter education course. One adult may supervise no more than two youths. 7. We prohibit.... One adult may supervise no more than one youth. 8. We prohibit participation in organized drives. D...

  19. 50 CFR 32.20 - Alabama.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...). 5. We allow shotguns with #4 shot or smaller, rifles firing .22 caliber rimfire ammunition, or... State-approved hunter education course. One adult may supervise no more than two youths. 7. We prohibit.... One adult may supervise no more than one youth. 8. We prohibit participation in organized drives. D...

  20. 50 CFR 32.20 - Alabama.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...). 5. We allow shotguns with #4 shot or smaller, rifles firing .22 caliber rimfire ammunition, or... State-approved hunter education course. One adult may supervise no more than two youths. 7. We prohibit.... One adult may supervise no more than one youth. 8. We prohibit participation in organized drives. D...

  1. 30 CFR 75.301 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... solid blocks of coal or rock so that any mixing of air currents between each is limited to leakage. AMS...-warning fire detection systems using newer technology that provides equal or greater protection, as...

  2. Low Power Wireless Smoke Alarm System in Home Fires

    PubMed Central

    Luis, Juan Aponte; Galán, Juan Antonio Gómez; Espigado, Javier Alcina

    2015-01-01

    A novel sensing device for fire detection in domestic environments is presented. The fire detector uses a combination of several sensors that not only detect smoke, but discriminate between different types of smoke. This feature avoids false alarms and warns of different situations. Power consumption is optimized both in terms of hardware and software, providing a high degree of autonomy of almost five years. Data gathered from the device are transmitted through a wireless communication to a base station. The low cost and compact design provides wide application prospects. PMID:26307994

  3. Low Power Wireless Smoke Alarm System in Home Fires.

    PubMed

    Aponte Luis, Juan; Gómez Galán, Juan Antonio; Alcina Espigado, Javier

    2015-08-21

    A novel sensing device for fire detection in domestic environments is presented. The fire detector uses a combination of several sensors that not only detect smoke, but discriminate between different types of smoke. This feature avoids false alarms and warns of different situations. Power consumption is optimized both in terms of hardware and software, providing a high degree of autonomy of almost five years. Data gathered from the device are transmitted through a wireless communication to a base station. The low cost and compact design provides wide application prospects.

  4. Iraq War: Defense Program Implications for Congress

    DTIC Science & Technology

    2003-06-04

    Sinnreich, Richard Hart. War Could Test Transformation The Hard Way. Lawton (Oklahoma) Constitution, February 16, 2003; Jaffe, Greg. Getting U.S...fire. McIntyre, Jamie . U.S. Crew Missing After F-15 Goes Down. CNN.Com, April 17, 2003; U.S. Army Helicopter Shot Down; 7 Killed, New York Times

  5. 27 CFR 53.11 - Meaning of terms.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., such as rifles, carbines, machine guns, shotguns, or fowling pieces, from which a shot, bullet, or... respect of which the violation occurs. Pistols. Small projectile firearms which have a short one-hand..., made, and intended to be aimed and fired from one hand. The term does not include gadget devices, guns...

  6. 27 CFR 53.11 - Meaning of terms.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., such as rifles, carbines, machine guns, shotguns, or fowling pieces, from which a shot, bullet, or... respect of which the violation occurs. Pistols. Small projectile firearms which have a short one-hand..., made, and intended to be aimed and fired from one hand. The term does not include gadget devices, guns...

  7. 27 CFR 53.11 - Meaning of terms.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., such as rifles, carbines, machine guns, shotguns, or fowling pieces, from which a shot, bullet, or... respect of which the violation occurs. Pistols. Small projectile firearms which have a short one-hand..., made, and intended to be aimed and fired from one hand. The term does not include gadget devices, guns...

  8. 27 CFR 53.11 - Meaning of terms.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., such as rifles, carbines, machine guns, shotguns, or fowling pieces, from which a shot, bullet, or... respect of which the violation occurs. Pistols. Small projectile firearms which have a short one-hand..., made, and intended to be aimed and fired from one hand. The term does not include gadget devices, guns...

  9. 27 CFR 53.11 - Meaning of terms.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., such as rifles, carbines, machine guns, shotguns, or fowling pieces, from which a shot, bullet, or... respect of which the violation occurs. Pistols. Small projectile firearms which have a short one-hand..., made, and intended to be aimed and fired from one hand. The term does not include gadget devices, guns...

  10. Lifetest of the High Output Maximum Efficiency Resonator (HOMER) Laser for the SAFFIRE Instrument on NASA's DESDynI Project

    NASA Technical Reports Server (NTRS)

    Stysley, Paul R.; Coyle, D. Barry; Kay, Richard B.; Frederickson, Robert; Poulios, Demetrios; Blair, Bryan; Scott, Stan; Arnold, Ed

    2011-01-01

    We update the status of a diode-pumped, Nd:YAG oscillator that is the prototype laser for NASA's DESDynI mission. After completing TRL-6 testing, this laser has fired over 5.5 billion shots in lifetesting.

  11. Modelling sound propagation in the Southern Ocean to estimate the acoustic impact of seismic research surveys on marine mammals

    NASA Astrophysics Data System (ADS)

    Breitzke, Monika; Bohlen, Thomas

    2010-05-01

    Modelling sound propagation in the ocean is an essential tool to assess the potential risk of air-gun shots on marine mammals. Based on a 2.5-D finite-difference code a full waveform modelling approach is presented, which determines both sound exposure levels of single shots and cumulative sound exposure levels of multiple shots fired along a seismic line. Band-limited point source approximations of compact air-gun clusters deployed by R/V Polarstern in polar regions are used as sound sources. Marine mammals are simulated as static receivers. Applications to deep and shallow water models including constant and depth-dependent sound velocity profiles of the Southern Ocean show dipole-like directivities in case of single shots and tubular cumulative sound exposure level fields beneath the seismic line in case of multiple shots. Compared to a semi-infinite model an incorporation of seafloor reflections enhances the seismically induced noise levels close to the sea surface. Refraction due to sound velocity gradients and sound channelling in near-surface ducts are evident, but affect only low to moderate levels. Hence, exposure zone radii derived for different hearing thresholds are almost independent of the sound velocity structure. With decreasing thresholds radii increase according to a spherical 20 log10 r law in case of single shots and according to a cylindrical 10 log10 r law in case of multiple shots. A doubling of the shot interval diminishes the cumulative sound exposure levels by -3 dB and halves the radii. The ocean bottom properties only slightly affect the radii in shallow waters, if the normal incidence reflection coefficient exceeds 0.2.

  12. The detection of gunshot residues in the nasal mucus of suspected shooters.

    PubMed

    Merli, Daniele; Brandone, Alberto; Amadasi, Alberto; Cattaneo, Cristina; Profumo, Antonella

    2016-07-01

    The identification and quantification of metallic residues produced by gunshots, called gunshot residues (GSR), provide crucial elements in forensic investigations. The research has been largely focused on their collection onto the hands of suspected shooters, but the method is often burdened by risks of contamination. This research was focused on the possibility of sampling GSR trapped inside the nasal mucus of consenting shooters. Samples of the nasal mucus of "blank" control subjects and shooters were chemically analysed by Instrumental Neutron Activation Analysis (INAA), for residues of antimony (Sb) and barium (Ba), while lead (Pb) was excluded as ubiquitously environmental contaminant and due to high instrumental quantification limit (IQL) of INAA for this element. Shots were fired using two types of weapons (pistols and revolvers) and different firing sequences. The mucus was sampled at different times: immediately after the shots, after 30-60-120 and 180 min. Different amounts of Sb and Ba were detected between controls and shooters, witnessing the ability of the nasal mucus to retain GSR at concentrations significantly different even from the highest basal levels. Moreover, in order to simulate actual cases, nasal mucus from five groups of shooters was sampled after different shots with the same weapon and cartridges, immediately and after 1, 3, 12, and 24 h. The highest values were always found in the first 3 h from firing, for both weapons. Interestingly, for all the weapons, significant Sb and Ba concentrations were also found up to 12 h after firing, contrary to what occurs on hands, even though a progressive decrease was detected, with values below the detection threshold only after 24 h, thus demonstrating that GSR are persistent in nasal mucus. These first results proving that both Sb and Ba were qualitatively detectable in the nasal mucus of shooters indicate that the chemical analysis of the nasal mucus of suspected shooters may represent a promising tool in the forensic field since it is less burdened by problems related to sampling or contamination than the usual sampling on hand, providing that ammunitions employed contain Ba and Sb.

  13. Recent Advances in Subsurface Imaging and Monitoring with Active Sources in China

    NASA Astrophysics Data System (ADS)

    Wang, B.; Chen, Y.; Wang, W.; Yang, W.

    2017-12-01

    Imaging high-resolution crustal structures and monitoring their temporal changes with active sources is essential to our understanding of regional tectonics and seismic hazards. In the past decades, great efforts has been made in China to looking for an ideal artificial seismic source to study continental crustal structures. After a mountain of field experiments, we developed permanent and portable seismic airgun sources for inland seismotectonic studies. Here we introduce several applications of using airgun source to imaging local crustal structures and monitoring velocity changes associated with natural and anthropogenic loadings. During Oct. 10th-20th, 2015, we carried out a crustal structure exploration experiment by firing portable airgun source along the Yangtze River in Anhui Province of eastern China. About 5000 shots were fired along 300km long section of the river. More than 2000 portable short period seismometers or geophones were deployed during the experiment. About 3000 of 5000 shots were fired at 20 fixed sites roughly evenly distributed along the river, and the rest shots were fired in the walkway. Seismic signal radiated by airgun source can be tracked to 350km. 2D/3D near surface and crustal velocity structure along the Yangtze River and adjacent region were inverted from airgun seismic records. Inverted velocity show well consistence with previous images and geological structure. The high resolution structural image provides a better understanding on regional geologic features and distribution of mineral resources. In the past five years, three Fixed Aigun Signal Transmitting Stations (FASTS) were built in western China. Those FASTS generate seismic signals with high repeatability, which can be tracked to the distance 1300 km. The highly reproducible signals are used to monitor the subtle subsurface changes. Observed diurnal and semi-diurnal velocity changes 10-4 are supposed to be results of barometrical and tidal loading. Suspicious velocity changes prior to several moderate earthquakes are detected around. Seismic velocity measured around the Hutubi underground gas storage show clear correlation with the gas pressure. Those results shed some light on the short term evolution of the shallow to low crust, which may boost our understanding the mechanism of local seismic hazards.

  14. Design of fire detection equipment based on ultraviolet detection technology

    NASA Astrophysics Data System (ADS)

    Liu, Zhenji; Liu, Jin; Chu, Sheng; Ping, Chao; Yuan, Xiaobing

    2015-03-01

    Utilized the feature of wide bandgap semiconductor of MgZnO, researched and developed a kind of Mid-Ultraviolet-Band(MUV) ultraviolet detector which has passed the simulation experiment in the sun circumstance. Based on the ultraviolet detector, it gives out a design scheme of gun-shot detection device, which is composed of twelve ultraviolet detectors, signal amplifier, processor, annunciator , azimuth indicator and the bracket. Through Analysing the feature of solar blind, ultraviolet responsivity, fire feature of gunshots and detection distance, the feasibility of this design scheme is proved.

  15. Scientists warn of 'trillion-dollar' spent-fuel risk

    NASA Astrophysics Data System (ADS)

    Gwynne, Peter

    2016-07-01

    A study by two Princeton University physicists suggests that a major fire in the spent nuclear fuel stored on the sites of US nuclear reactors could “dwarf the horrific consequences of the Fukushima accident”.

  16. Working toward the elimination of residential fire deaths: the Centers for Disease Control and Prevention's Smoke Alarm Installation and Fire Safety Education (SAIFE) program.

    PubMed

    Ballesteros, Michael F; Jackson, Mark L; Martin, Maurice W

    2005-01-01

    To address residential fires and related injuries, the Centers for Disease Control and Prevention funds state health departments to deliver a Smoke Alarm Installation and Fire Safety Education (SAIFE) program in high-risk homes in 16 states. This program involves recruiting local communities and community partners, hiring a local coordinator, canvassing neighborhood homes, installing long-lasting lithium-powered smoke alarms, and providing general fire safety education and 6-month follow-up to determine alarm functionality. Local fire departments are vital community partners in delivering this program. Since the program's inception, more than 212,000 smoke alarms have been installed in more than 126,000 high-risk homes. Additionally, approximately 610 lives have potentially been saved as a result of a program alarm that provided early warning to a dangerous fire incident.

  17. Predicting Fire Season Severity in South America Using Sea Surface Temperature Anomalies

    NASA Technical Reports Server (NTRS)

    Chen, Yang; Randerson, James T.; Morton, Douglas C.; Jin, Yufang; DeFries, Ruth S.; Collatz, George J.; Kasibhatla, Prasad S.; Giglio, Louis; Jin, Yufang; Marlier, Miriam

    2011-01-01

    Fires in South America cause forest degradation and contribute to carbon emissions associated with land use change. Here we investigated the relationship between year-to-year changes in satellite-derived estimates of fire activity in South America and sea surface temperature (SST) anomalies. We found that the Oceanic Ni o Index (ONI) was correlated with interannual fire activity in the eastern Amazon whereas the Atlantic Multidecadal Oscillation (AMO) index was more closely linked with fires in the southern and southwestern Amazon. Combining these two climate indices, we developed an empirical model that predicted regional annual fire season severity (FSS) with 3-5 month lead times. Our approach provides the foundation for an early warning system for forecasting the vulnerability of Amazon forests to fires, thus enabling more effective management with benefits for mitigation of greenhouse gas and air pollutant emissions.

  18. One shot, one kill: the forces delivered by archer fish shots to distant targets.

    PubMed

    Burnette, Morgan F; Ashley-Ross, Miriam A

    2015-10-01

    Archer fishes are skillful hunters of terrestrial prey, firing jets of water that dislodge insects perched on overhead vegetation. In the current investigation, we sought an answer to the question: are distant targets impractical foraging choices? Targets far from the shooter might not be hit with sufficient force to cause them to fall. However, observations from other investigators show that archer fish fire streams of water that travel in a non-ballistic fashion, which is thought to keep on-target forces high, even to targets that are several body lengths distant from the fish. We presented targets at different distances and investigated three aspects of foraging behavior: (i) on-target forces, (ii) shot velocity, (iii) a two-target choice assay to determine if fish would show any preference for downing closer targets or more distant targets. In general, shots from our fish (Toxotes chatareus) showed a mild decrease (less than 15% on average) in on-target forces at our most distant target offered (5.8 body lengths) with respect to the closest target offered (2.3 body lengths). One individual in our investigation showed slightly, but significantly, greater on-target forces as target distance increased. Forces on the furthest targets offered were found to double that of attachment forces for 200mg insects, even for individuals whose on-target forces showed mild decreases with increases in target distance. High-speed video analysis of jet impact with the target revealed that the shot was traveling in a non-ballistic manner, even to our most distant target offered, corroborating previous suppositions that on-target forces should remain high. Fish were able to accomplish this without large changes to shot velocity, but we did find evidence that the water jets appeared to differ in the timing of their acceleration as target distance increased. Our two-target choice experiment revealed that fish show preference for downing the closer target first, even though impact forces on distant targets only showed mild decreases. Our overall findings (and the findings of others) suggest that archer fish modulate many aspects of their shooting behavior: from target selection to active control over the water jet that allows the fish to deliver reliably forceful impacts to prey over a wide range of distances. Copyright © 2015 Elsevier GmbH. All rights reserved.

  19. Smoke Detector

    NASA Technical Reports Server (NTRS)

    1979-01-01

    In the photo, Fire Chief Jay Stout of Safety Harbor, Florida, is explaining to young Richard Davis the workings of the Honeywell smoke and fire detector which probably saved Richard's life and that of his teen-age brother. Alerted by the detector's warning, the pair were able to escape their burning home. The detector in the Davis home was one of 1,500 installed in Safety Harbor residences in a cooperative program conducted by the city and Honeywell Inc.

  20. Nunatchiagmi (Stories about Buckland).

    ERIC Educational Resources Information Center

    Thomas, Evans

    Printed in both Inupiat and English, this 32 page booklet recounts stories of native life in Buckland, Alaska. It is printed in large type and simply written; illustrations accompany each short narrative. Several stories are told by Evans Thomas who remembers his boyhood days as he fired a shotgun for the first time, shot his first seal, broke a…

  1. The Coast Artillery Journal. Volume 58, Number 2, February 1923

    DTIC Science & Technology

    1923-02-01

    firing mechanism block with a fresh primer in place. No.5 acted as a powder runner between the powder pit and No.2. Nos. 6 and 7 carried the loading...obstruct these routes. Xumerous passive obstructions have been conceived: metallic cables raised and maintained in the air by kites ; cables shot into the

  2. THE MATHEMATICAL ANALYSIS OF A SIMPLE DUEL

    DTIC Science & Technology

    The principles and techniques of simple Markov processes are used to analyze a simple duel to determine the limiting state probabilities (i.e., the...probabilities of occurrence of the various possible outcomes of the duel ). The duel is one in which A fires at B at a rate of r sub A shots per minute

  3. 50 CFR 32.20 - Alabama.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... hunting. One adult may supervise no more than two youth hunters. 4. We prohibit the use of horses, mules... #4 shot or smaller (see § 32.2(k)), rifles and handguns using rim-fire ammunition only, or archery... licensed and permitted adult 21 years of age or older, and must remain with the adult while hunting. One...

  4. Creating a Better End Games Strategy: Fully Exploiting the Capabilities of Multiple Disciplines

    DTIC Science & Technology

    2013-09-01

    example, in 2011, approximately 2,200 raids were conducted, and the Pentagon has estimated 90 percent of these raids “end without a shot fired ...first chances to demonstrate the HIG’s value. Abdulmutallab tried to detonate a bomb hidden in his underwear while traveling on a Northwest

  5. Impact of handgun types on gun assault outcomes: a comparison of gun assaults involving semiautomatic pistols and revolvers

    PubMed Central

    Reedy, D; Koper, C

    2003-01-01

    Objective: To examine whether gun assaults committed with semiautomatic pistols are more injurious and lethal than those committed with revolvers. Setting: Jersey City, New Jersey from 1992 through 1996. Methods: Using police records on fatal and non-fatal handgun assaults, t tests and χ2 tests were employed to determine if attacks with pistols result in more shots fired than those with revolvers, leading to more gunshot victims and more severely wounded victims. Results: More shots were fired in attacks with pistols (average = 3.2 to 3.7) than in attacks with revolvers (average = 2.3 to 2.6). Although pistol use was unrelated to the probability that an incident resulted in any injury or death, it was associated with a 15% increase in the number of wounded victims in those cases in which people were shot (1.15 per pistol case, 1.0 per revolver case), implying that the total number of gunshot victims may have been 9.4% lower had pistols not been used in any attacks. Pistol use was not related to the number of wounds per gunshot victim. Conclusions: The findings provide limited evidence that recent growth in the production and use of pistols has contributed to higher levels of gunshot victimizations. However, available data did not permit an assessment of whether the associations between gun types and assault outcomes are mediated by characteristics of incidents and actors. PMID:12810743

  6. Early Warning Systems Assure Safe Schools

    ERIC Educational Resources Information Center

    Greenhalgh, John

    1973-01-01

    Fairfield, Connecticut, public schools are protected by an automatic fire detection system covering every area of every building through an electric monitor. An intrusion alarm system that relies primarily on pulsed infra-red beams protects the plant investment. (Author/MF)

  7. Depopulation of rural landscapes exacerbates fire activity in the western Amazon.

    PubMed

    Uriarte, María; Pinedo-Vasquez, Miquel; DeFries, Ruth S; Fernandes, Katia; Gutierrez-Velez, Victor; Baethgen, Walter E; Padoch, Christine

    2012-12-26

    Destructive fires in Amazonia have occurred in the past decade, leading to forest degradation, carbon emissions, impaired air quality, and property damage. Here, we couple climate, geospatial, and province-level census data, with farmer surveys to examine the climatic, demographic, and land use factors associated with fire frequency in the Peruvian Amazon from 2000 to 2010. Although our results corroborate previous findings elsewhere that drought and proximity to roads increase fire frequency, the province-scale analysis further identifies decreases in rural populations as an additional factor. Farmer survey data suggest that increased burn scar frequency and size reflect increased flammability of emptying rural landscapes and reduced capacity to control fire. With rural populations projected to decline, more frequent drought, and expansion of road infrastructure, fire risk is likely to increase in western Amazonia. Damage from fire can be reduced through warning systems that target high-risk locations, coordinated fire fighting efforts, and initiatives that provide options for people to remain in rural landscapes.

  8. Spatial temporal clustering for hotspot using kulldorff scan statistic method (KSS): A case in Riau Province

    NASA Astrophysics Data System (ADS)

    Hudjimartsu, S. A.; Djatna, T.; Ambarwari, A.; Apriliantono

    2017-01-01

    The forest fires in Indonesia occurs frequently in the dry season. Almost all the causes of forest fires are caused by the human activity itself. The impact of forest fires is the loss of biodiversity, pollution hazard and harm the economy of surrounding communities. To prevent fires required the method, one of them with spatial temporal clustering. Spatial temporal clustering formed grouping data so that the results of these groupings can be used as initial information on fire prevention. To analyze the fires, used hotspot data as early indicator of fire spot. Hotspot data consists of spatial and temporal dimensions can be processed using the Spatial Temporal Clustering with Kulldorff Scan Statistic (KSS). The result of this research is to the effectiveness of KSS method to cluster spatial hotspot in a case within Riau Province and produces two types of clusters, most cluster and secondary cluster. This cluster can be used as an early fire warning information.

  9. Tropical North Atlantic ocean-atmosphere interactions synchronize forest carbon losses from hurricanes and Amazon fires

    NASA Astrophysics Data System (ADS)

    Chen, Yang; Randerson, James T.; Morton, Douglas C.

    2015-08-01

    We describe a climate mode synchronizing forest carbon losses from North and South America by analyzing time series of tropical North Atlantic sea surface temperatures (SSTs), landfall hurricanes and tropical storms, and Amazon fires during 1995-2013. Years with anomalously high tropical North Atlantic SSTs during March-June were often followed by a more active hurricane season and a larger number of satellite-detected fires in the southern Amazon during June-November. The relationship between North Atlantic tropical cyclones and southern Amazon fires (r = 0.61, p < 0.003) was stronger than links between SSTs and either cyclones or fires alone, suggesting that fires and tropical cyclones were directly coupled to the same underlying atmospheric dynamics governing tropical moisture redistribution. These relationships help explain why seasonal outlook forecasts for hurricanes and Amazon fires both failed in 2013 and may enable the design of improved early warning systems for drought and fire in Amazon forests.

  10. Depopulation of rural landscapes exacerbates fire activity in the western Amazon

    PubMed Central

    Uriarte, María; Pinedo-Vasquez, Miquel; DeFries, Ruth S.; Fernandes, Katia; Gutierrez-Velez, Victor; Baethgen, Walter E.; Padoch, Christine

    2012-01-01

    Destructive fires in Amazonia have occurred in the past decade, leading to forest degradation, carbon emissions, impaired air quality, and property damage. Here, we couple climate, geospatial, and province-level census data, with farmer surveys to examine the climatic, demographic, and land use factors associated with fire frequency in the Peruvian Amazon from 2000 to 2010. Although our results corroborate previous findings elsewhere that drought and proximity to roads increase fire frequency, the province-scale analysis further identifies decreases in rural populations as an additional factor. Farmer survey data suggest that increased burn scar frequency and size reflect increased flammability of emptying rural landscapes and reduced capacity to control fire. With rural populations projected to decline, more frequent drought, and expansion of road infrastructure, fire risk is likely to increase in western Amazonia. Damage from fire can be reduced through warning systems that target high-risk locations, coordinated fire fighting efforts, and initiatives that provide options for people to remain in rural landscapes. PMID:23236144

  11. Warning! fire in the ICU.

    PubMed

    Rispoli, Fabio; Iannuzzi, Michele; De Robertis, Edoardo; Piazza, Ornella; Servillo, Giuseppe; Tufano, Rosalba

    2014-06-01

    At 5:30 pm on December 17, 2010, shortly after a power failure, smoke filled the Intensive Care Unit (ICU) of Federico II University Hospital in Naples, Italy, triggering the hospital emergency alarm system. Immediately, staff began emergency procedures and alerted rescue teams. All patients were transferred without harm. The smoke caused pharyngeal and conjunctival irritation in some staff members. After a brief investigation, firefighters discovered the cause of the fire was a failure of the Uninterruptible Power Supply (UPS).

  12. Prediction of spatially explicit rainfall intensity–duration thresholds for post-fire debris-flow generation in the western United States

    USGS Publications Warehouse

    Staley, Dennis M.; Negri, Jacquelyn; Kean, Jason W.; Laber, Jayme L.; Tillery, Anne C.; Youberg, Ann M.

    2017-01-01

    Early warning of post-fire debris-flow occurrence during intense rainfall has traditionally relied upon a library of regionally specific empirical rainfall intensity–duration thresholds. Development of this library and the calculation of rainfall intensity-duration thresholds often require several years of monitoring local rainfall and hydrologic response to rainstorms, a time-consuming approach where results are often only applicable to the specific region where data were collected. Here, we present a new, fully predictive approach that utilizes rainfall, hydrologic response, and readily available geospatial data to predict rainfall intensity–duration thresholds for debris-flow generation in recently burned locations in the western United States. Unlike the traditional approach to defining regional thresholds from historical data, the proposed methodology permits the direct calculation of rainfall intensity–duration thresholds for areas where no such data exist. The thresholds calculated by this method are demonstrated to provide predictions that are of similar accuracy, and in some cases outperform, previously published regional intensity–duration thresholds. The method also provides improved predictions of debris-flow likelihood, which can be incorporated into existing approaches for post-fire debris-flow hazard assessment. Our results also provide guidance for the operational expansion of post-fire debris-flow early warning systems in areas where empirically defined regional rainfall intensity–duration thresholds do not currently exist.

  13. Prediction of spatially explicit rainfall intensity-duration thresholds for post-fire debris-flow generation in the western United States

    NASA Astrophysics Data System (ADS)

    Staley, Dennis M.; Negri, Jacquelyn A.; Kean, Jason W.; Laber, Jayme L.; Tillery, Anne C.; Youberg, Ann M.

    2017-02-01

    Early warning of post-fire debris-flow occurrence during intense rainfall has traditionally relied upon a library of regionally specific empirical rainfall intensity-duration thresholds. Development of this library and the calculation of rainfall intensity-duration thresholds often require several years of monitoring local rainfall and hydrologic response to rainstorms, a time-consuming approach where results are often only applicable to the specific region where data were collected. Here, we present a new, fully predictive approach that utilizes rainfall, hydrologic response, and readily available geospatial data to predict rainfall intensity-duration thresholds for debris-flow generation in recently burned locations in the western United States. Unlike the traditional approach to defining regional thresholds from historical data, the proposed methodology permits the direct calculation of rainfall intensity-duration thresholds for areas where no such data exist. The thresholds calculated by this method are demonstrated to provide predictions that are of similar accuracy, and in some cases outperform, previously published regional intensity-duration thresholds. The method also provides improved predictions of debris-flow likelihood, which can be incorporated into existing approaches for post-fire debris-flow hazard assessment. Our results also provide guidance for the operational expansion of post-fire debris-flow early warning systems in areas where empirically defined regional rainfall intensity-duration thresholds do not currently exist.

  14. Black Thunder Coal Mine and Los Alamos National Laboratory experimental study of seismic energy generated by large scale mine blasting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, R.L.; Gross, D.; Pearson, D.C.

    In an attempt to better understand the impact that large mining shots will have on verifying compliance with the international, worldwide, Comprehensive Test Ban Treaty (CTBT, no nuclear explosion tests), a series of seismic and videographic experiments has been conducted during the past two years at the Black Thunder Coal Mine. Personnel from the mine and Los Alamos National Laboratory have cooperated closely to design and perform experiments to produce results with mutual benefit to both organizations. This paper summarizes the activities, highlighting the unique results of each. Topics which were covered in these experiments include: (1) synthesis of seismic,more » videographic, acoustic, and computer modeling data to improve understanding of shot performance and phenomenology; (2) development of computer generated visualizations of observed blasting techniques; (3) documentation of azimuthal variations in radiation of seismic energy from overburden casting shots; (4) identification of, as yet unexplained, out of sequence, simultaneous detonation in some shots using seismic and videographic techniques; (5) comparison of local (0.1 to 15 kilometer range) and regional (100 to 2,000 kilometer range) seismic measurements leading to determine of the relationship between local and regional seismic amplitude to explosive yield for overburden cast, coal bulking and single fired explosions; and (6) determination of the types of mining shots triggering the prototype International Monitoring System for the CTBT.« less

  15. Information transmission in hippocampal CA1 neuron models in the presence of poisson shot noise: the case of periodic sub-threshold spike trains.

    PubMed

    Kawaguchi, Minato; Mino, Hiroyuki; Durand, Dominique M

    2006-01-01

    This article presents an analysis of the information transmission of periodic sub-threshold spike trains in a hippocampal CA1 neuron model in the presence of a homogeneous Poisson shot noise. In the computer simulation, periodic sub-threshold spike trains were presented repeatedly to the midpoint of the main apical branch, while the homogeneous Poisson shot noise was applied to the mid-point of a basal dendrite in the CA1 neuron model consisting of the soma with one sodium, one calcium, and five potassium channels. From spike firing times recorded at the soma, the inter spike intervals were generated and then the probability, p(T), of the inter-spike interval histogram corresponding to the spike interval, r, of the periodic input spike trains was estimated to obtain an index of information transmission. In the present article, it is shown that at a specific amplitude of the homogeneous Poisson shot noise, p(T) was found to be maximized, as well as the possibility to encode the periodic sub-threshold spike trains became greater. It was implied that setting the amplitude of the homogeneous Poisson shot noise to the specific values which maximize the information transmission might contribute to efficiently encoding the periodic sub-threshold spike trains by utilizing the stochastic resonance.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toksoz, M N; Kuleli, S; Gurbuz, C

    The objective of this project is to calibrate regional travel-times and propagation characteristics of seismic waves in Turkey and surrounding areas in the Middle East in order to enhance detection and location capabilities in the region. Important data for the project will be obtained by large calibration shots in central and eastern Turkey. The first, a two-ton shot, was fired in boreholes near Keskin in central Anatolia on 23 November 2002. The explosives were placed in 14 holes, each 80 m deep, arranged in concentric circular arrays. Ninety temporary seismic stations were deployed within a 300 km radius around themore » shot. The permanent stations of the Turkish National Seismic Network provided a good azimuthal coverage as well as three radial traverses. Most stations within a radius of 200 km recorded the shot. Travel-time data have been analyzed to obtain a detailed crustal model under the shot and along the profiles. The model gives a 35 km thick crust, characterized by two layers with velocities of 5.0 and 6.4 km/s. The P{sub n} velocity was found to be 7.8 km/s. The crustal thickness decreases to the north where the profile crosses the North Anatolian fault. There is a slight increase in crustal velocities, but no change in crustal thickness to the west. Data analysis effort is continuing to refine the regional velocity models and to obtain station corrections.« less

  17. TED: a novel man portable infrared detection and situation awareness system

    NASA Astrophysics Data System (ADS)

    Tidhar, Gil; Manor, Ran

    2007-04-01

    Infrared Search and Track (IRST) and threat warning systems are used in vehicle mounted or in fixed land positions. Migration of this technology to the man portable applications proves to be difficult due to the tight constraints of power consumption, dimensions, weight and due to the high video rate requirements. In this report we provide design details of a novel transient event detection (TED) system, capable of detection of blasts and gun shot events in a very wide field of view, while used by an operator in motion

  18. The double slit experiment and the time reversed fire alarm

    NASA Astrophysics Data System (ADS)

    Halabi, Tarek

    2011-03-01

    When both slits of the double slit experiment are open, closing one paradoxically increases the detection rate at some points on the detection screen. Feynman famously warned that temptation to "understand" such a puzzling feature only draws us into blind alleys. Nevertheless, we gain insight into this feature by drawing an analogy between the double slit experiment and a time reversed fire alarm. Much as closing the slit increases probability of a future detection, ruling out fire drill scenarios, having heard the fire alarm, increases probability of a past fire (using Bayesian inference). Classically, Bayesian inference is associated with computing probabilities of past events. We therefore identify this feature of the double slit experiment with a time reversed thermodynamic arrow. We believe that much of the enigma of quantum mechanics is simply due to some variation of time's arrow.

  19. Charge-flow structures as polymeric early-warning fire alarm devices. M.S. Thesis; [metal oxide semiconductors

    NASA Technical Reports Server (NTRS)

    Sechen, C. M.; Senturia, S. D.

    1977-01-01

    The charge-flow transistor (CFT) and its applications for fire detection and gas sensing were investigated. The utility of various thin film polymers as possible sensing materials was determined. One polymer, PAPA, showed promise as a relative humidity sensor; two others, PFI and PSB, were found to be particularly suitable for fire detection. The behavior of the charge-flow capacitor, which is basically a parallel-plate capacitor with a polymer-filled gap in the metallic tip electrode, was successfully modeled as an RC transmission line. Prototype charge-flow transistors were fabricated and tested. The effective threshold voltage of this metal oxide semiconductor was found to be dependent on whether surface or bulk conduction in the thin film was dominant. Fire tests with a PFI-coated CFT indicate good sensitivity to smouldering fires.

  20. A Bullet Fired in Dry Water: An Investigative Activity to Learn Hydrodynamics Concepts

    ERIC Educational Resources Information Center

    Leitão, Ulisses Azevedo; dos Anjos Pinheiro da Silva, Antonio; Trindade do Nascimento, Natália Cristina; da Cruz Gervásio, Lilian Mara Benedita

    2017-01-01

    In this paper we report an investigative activity on hydrodynamics, in the context of an inquiry-based learning project. The aim is to analyse the experiment of a bullet shot underwater. Using "Tracker," a video analysing and modelling software, the displacement of the bullet was measured as function of time, processing a slow motion…

  1. 14 CFR Appendix C to Part 121 - C-46 Nontransport Category Airplanes

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... discharge shall be such as to provide a minimum of one adequate discharge for each designated fire zone... of discharging, e.g., mechanical cutterheads, electric cartridge, or other method; and whether a one- or two-shot system is used; and if the latter is used, means of cross-feeding or otherwise selecting...

  2. The Effectiveness of Reverse Telephon Emergency Warning Systems in the October 2007 San Diego Wildfires

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sorensen, John H; Sorensen, Barbara Vogt

    2009-01-01

    Late in October, 2007, fast-moving wildfires fueled by extreme Santa Ana winds threatened residents and their properties in San Diego County, California. The impacted area also included the City of San Diego within the County s boundaries. It turns out the San Diego firestorms would be the biggest in the County's history, surpassing the devastating 2003 firestorms in intensity, duration, and impacted populations. Both San Diego County and the City of San Diego have installed telephone reverse call-down emergency warning systems. A telephone survey of 1200 households located in areas identified by emergency officials as the evacuation zones for themore » 2007 fires was conducted in late March and early April 2008 using a random telephone dialing process to determine if people responded to the reverse telephone warning systems calls. Findings indicate that those who received a reverse emergency warning call were much more likely to evacuate than those who did not receive a call. The telephone calls were also the most likely source of first warning.« less

  3. Characteristics and Frequency of Chipping Effects in Near-Contact Gunshot Wounds.

    PubMed

    Amadasi, Alberto; Mazzarelli, Debora; Merli, Daniele; Brandone, Alberto; Cattaneo, Cristina

    2017-05-01

    The presence of "chipping" or "flaking" around the edges of gunshot entry wounds has been described among the characteristics of gunshot wounds in bone. In this study, the real frequency of such a peculiar feature was investigated. The presence of "chipping" was assessed on 22 gunshot wounds fired at a near-contact range on bovine ribs with 9-mm bullets. As controls, five samples were shot with a 3 cm range, and five from 40 cm. In 77% of cases shot at near-contact range, a detachment of small fragments of the upper layers of bone was detected, mainly with a circumferential disposition, whereas this feature was lacking in control samples. The study demonstrated the frequency of "chipping" and that it may probably be due to a combined ballistic effect of impact of the bullet itself and expansion of gases. It may be thus considered indicative of close-range shots. © 2016 American Academy of Forensic Sciences.

  4. The analysis and modeling of the ARDEC 2.5 km/s 20-mm plasma railgun shot

    NASA Astrophysics Data System (ADS)

    Sink, D. A.; Chang, D. I.; Davis, A.; Colombo, G.; Hildenbrand, D. J.

    1993-01-01

    The 20-mm round-bore plasma railgun was successfully fired at the ARDEC electric gun facility. The 4-m gun with copper rails and alumina composite insulators was operated using a light-gas gun injector to start the projectile, already located in the gun, moving prior to the introduction of current. Current from the EMACK homopolar generator (HPG) was commutated into the gun by an explosively-actuated opening switch. The muzzle velocity was recorded by breakwires and flash X-rays at 2.5 km/s. B-dot sensors, rail current Rogowski coils, and breech and muzzle voltage measurements provided data on the in-bore dynamics of the armature. Post-shot analysis using the ARMRAIL (ARMature Physics and RAILgun Performance Model) code successfully provided calculations reproducing all the main features of the data. Models account for the observed secondary arcs present throughout the shot and the basis for the code and physics modeling is given.

  5. Incipient fire detection system

    DOEpatents

    Brooks, Jr., William K.

    1999-01-01

    A method and apparatus for an incipient fire detection system that receives gaseous samples and measures the light absorption spectrum of the mixture of gases evolving from heated combustibles includes a detector for receiving gaseous samples and subjecting the samples to spectroscopy and determining wavelengths of absorption of the gaseous samples. The wavelengths of absorption of the gaseous samples are compared to predetermined absorption wavelengths. A warning signal is generated whenever the wavelengths of absorption of the gaseous samples correspond to the predetermined absorption wavelengths. The method includes receiving gaseous samples, subjecting the samples to light spectroscopy, determining wavelengths of absorption of the gaseous samples, comparing the wavelengths of absorption of the gaseous samples to predetermined absorption wavelengths and generating a warning signal whenever the wavelengths of absorption of the gaseous samples correspond to the predetermined absorption wavelengths. In an alternate embodiment, the apparatus includes a series of channels fluidically connected to a plurality of remote locations. A pump is connected to the channels for drawing gaseous samples into the channels. A detector is connected to the channels for receiving the drawn gaseous samples and subjecting the samples to spectroscopy. The wavelengths of absorption are determined and compared to predetermined absorption wavelengths is provided. A warning signal is generated whenever the wavelengths correspond.

  6. Fatal contact shot to the chest caused by the gas jet from a muzzle-loading pistol discharging only black powder and no bullet: case study and experimental simulation of the wounding effect.

    PubMed

    Große Perdekamp, Markus; Glardon, Matthieu; Kneubuehl, Beat P; Bielefeld, Lena; Nadjem, Hadi; Pollak, Stefan; Pircher, Rebecca

    2015-01-01

    In modern medico-legal literature, only a small number of publications deal with fatal injuries from black powder guns. Most of them focus on the morphological features such as intense soot soiling, blast tattooing and burn effects in close-range shots or describe the wound ballistics of spherical lead bullets. Another kind of "unusual" and potentially lethal weapons are handguns destined for firing only blank cartridges such as starter and alarm pistols. The dangerousness of these guns is restricted to very close and contact range shots and results from the gas jet produced by the deflagration of the propellant. The present paper reports on a suicide committed with a muzzle-loading percussion pistol cal. 45. An unusually large stellate entrance wound was located in the precordial region, accompanied by an imprint mark from the ramrod and a faint greenish discoloration (apparently due to the formation of sulfhemoglobin). Autopsy revealed an oversized powder cavity, multiple fractures of the anterior thoracic wall as well as ruptures of the heart, the aorta, the left hepatic lobe and the diaphragm. In total, the zone of mechanical destruction had a diameter of approx. 15 cm. As there was no exit wound and no bullet lodged in the body, the injury was caused exclusively by the inrushing combustion gases of the propellant (black powder) comparable with the gas jet of a blank cartridge gun. In contact shots to ballistic gelatine using the suicide's pistol loaded with black powder but no projectile, the formation of a nearly spherical cavity could be demonstrated by means of a high-speed camera. The extent of the temporary cavity after firing with 5 g of black powder roughly corresponded to the zone of destruction found in the suicide's body.

  7. Aircraft Command in Emergency Situations (ACES). Phase 1: Concept Development

    DTIC Science & Technology

    1991-04-01

    progresses through a sequence of four stages: incipient, smoldeang, flame, and heat ( ASHREA Handbook 1984 Systems, Chapter 38, Fire and Sino’.e Control...CARGO F FCARGO DETI DET 2 1D DET2 Figure 6-9. Synoptic Display Layout for Concept R SMOKE HEATt I I 110 T AFTCARGO ~HEAT VS TIME SMOKE VS TIME HEAVY 7II...Phosphate Road, Suite 110 , North Charleston, SC 29418. Reference 12 Senturia, S. D., "Fabrication and Evaluation of Polymeric Early-Warning Fire Alarm

  8. Preparing for Emergencies: A Checklist for People with Neuromuscular Diseases

    MedlinePlus

    TORNADO • FLASH FLOOD • EARTHQUAKE • WINTER STORM • HURRICANE • FIRE • HAZARDOUS MATERIALS SPILL Preparing for Emergencies A Checklist for ... head for a basement when there is a tornado warning, but most basements aren’t wheelchair-accessible. ...

  9. 30 CFR 75.301 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-warning fire detection systems using newer technology that provides equal or greater protection, as... be purchased from the American Society for Testing Materials (ASTM), 1916 Race Street, Philadelphia..., copies of the document can be purchased from the American Society for Testing Materials (ASTM), 100 Barr...

  10. An Implementing Strategy for Improving Wildland Fire Environmental Literacy

    NASA Astrophysics Data System (ADS)

    McCalla, M. R.; Andrus, D.; Barnett, K.

    2007-12-01

    Wildland fire is any planned or unplanned fire which occurs in wildland ecosystems. Wildland fires affect millions of acres annually in the U.S. An average of 5.4 million acres a year were burned in the U.S. between 1995 and 2004, approximately 142 percent of the average burned area between 1984 and 1994. In 2005 alone, Federal agencies spent nearly $1 billion on fire suppression and state and local agencies contributed millions more. Many Americans prefer to live and vacation in relatively remote surroundings, (i.e., woods and rangelands). These choices offer many benefits, but they also present significant risks. Most of North America is fire-prone and every day developed areas and home sites are extending further into natural wildlands, which increases the chances of catastrophic fire. In addition, an abundance of accumulated biomass in forests and rangelands and persistent drought conditions are contributing to larger, costlier wildland fires. To effectively prevent, manage, suppress, respond to, and recover from wildland fires, fire managers, and other communities which are impacted by wildland fires (e.g., the business community; healthcare providers; federal, state, and local policymakers; the media; the public, etc.) need timely, accurate, and detailed wildland fire weather and climate information to support their decision-making activities. But what are the wildland fire weather and climate data, products, and information, as well as information dissemination technologies, needed to reach out and promote wildland fire environmental literacy in these communities? The Office of the Federal Coordinator for Meteorological Services and Supporting Research (OFCM) conducted a comprehensive review and assessment of weather and climate needs of providers and users in their wildland fire and fuels management activities. The assessment has nine focus areas, one of which is environmental literacy (e.g., education, training, outreach, partnering, and collaboration). The OFCM model for promoting wildland fire environmental literacy, the model's component parts, as well as an implementing strategy to execute the model will be presented. That is, the presentation will lay out the framework and methodology which the OFCM used to systematically define the wildland fire weather and climate education and outreach needs through interdepartmental collaboration within the OFCM coordinating infrastructure. A key element of the methodology is to improve the overall understanding and use of wildland fire forecast and warning climate and weather products and to exploit current and emerging technologies to improve the dissemination of customer-tailored forecast and warning information and products to stakeholders and users. Thus, the framework and methodology define the method used to determine the target public, private, and academic sector audiences. The methodology also identifies the means for determining the optimal channels, formats, and content for informing end users in time for effective action to be taken.

  11. [The boundary ranges of the free flight of particles of gunpowder and metals in shots from a hand firearm].

    PubMed

    Popov, V L; Isakov, V D; Krivozheĭko, A G

    1990-01-01

    On the basis of equations of external ballistics and probability theory the largest possible distances of free (independent) flight of gunshot powder and metal particles having different forms and sizes were calculated. Experimental control of the calculated data for different types of battle and sports hand fire-arms was carried out. The correspondence of the calculated data to maximal free (independent) particle flight in blank shots was stated. In experiments with cartridges equipped with bullets the distances of free particle flight were significantly lesser (by 53-65%) which may be connected with effect of gunshot projectile on the process of particle distribution. Reversed adapted formulas and calculation variants are presented.

  12. Application of a CO2 dial system for infrared detection of forest fire and reduction of false alarm

    NASA Astrophysics Data System (ADS)

    Bellecci, C.; Francucci, M.; Gaudio, P.; Gelfusa, M.; Martellucci, S.; Richetta, M.; Lo Feudo, T.

    2007-04-01

    Forest fires can be the cause of serious environmental and economic damages. For this reason considerable effort has been directed toward forest protection and fire fighting. The means traditionally used for early fire detection mainly consist in human observers dispersed over forest regions. A significant improvement in early warning capabilities could be obtained by using automatic detection apparatus. In order to early detect small forest fires and minimize false alarms, the use of a lidar system and dial technique will be considered. A first evaluation of the lowest detectable concentration will be estimated by numerical simulation. The theoretical model will also be used to get the capability of the dial system to control wooded areas. Fixing the burning rate for several fuels, the maximum range of detection will be evaluated. Finally results of simulations will be reported.

  13. Ultrahigh contrast from a frequency-doubled chirped-pulse-amplification beamline.

    PubMed

    Hillier, David; Danson, Colin; Duffield, Stuart; Egan, David; Elsmere, Stephen; Girling, Mark; Harvey, Ewan; Hopps, Nicholas; Norman, Michael; Parker, Stefan; Treadwell, Paul; Winter, David; Bett, Thomas

    2013-06-20

    This paper describes frequency-doubled operation of a high-energy chirped-pulse-amplification beamline. Efficient type-I second-harmonic generation was achieved using a 3 mm thick 320 mm aperture KDP crystal. Shots were fired at a range of energies achieving more than 100 J in a subpicosecond, 527 nm laser pulse with a power contrast of 10(14).

  14. Operation Greenhouse. Scientific Director's report of atomic-weapon tests at Eniwetok, 1951. Annex 1. 11. Timing and firing and fiducial markers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grier, H.E.

    1985-09-01

    An automatic remote-control system armed and fired the bomb and sent out a sequence of time signals to experimental equipment on the atoll. A central station at Parry Island sent signals via submarine cables to a timer station on a shot island. The timer station controlled signals to the zero station and to experiments on the island, and through auxiliary stations, it also controlled signal distribution on adjacent islands. Light-sensitive triggering units for apparatus and for accurate standard zero-time reference were provided in the form of Blue Boxes, or fiducial markers.

  15. Potential for Expanding the Near Real Time ForWarn Regional Forest Monitoring System to Include Alaska

    NASA Technical Reports Server (NTRS)

    Spruce, Joseph P.; Gasser, Gerald; Hargrove, William; Smoot, James; Kuper, Philip D.

    2014-01-01

    The on-line near real time (NRT) ForWarn system is currently deployed to monitor regional forest disturbances within the conterminous United States (CONUS), using daily MODIS Aqua and Terra NDVI data to derive monitoring products. The Healthy Forest Restoration Act of 2003 mandated such a system. Work on ForWarn began in 2006 with development and validation of retrospective MODIS NDVI-based forest monitoring products. Subsequently, NRT forest disturbance monitoring products were demonstrated, leading to the actual system deployment in 2010. ForWarn provides new CONUS forest disturbance monitoring products every 8 days, using USGS eMODIS data for current NDVI. ForWarn currently does not cover Alaska, which includes extensive forest lands at risk to multiple biotic and abiotic threats. This poster discusses a case study using Alaska eMODIS Terra data to derive ForWarn like forest change products during the 2010 growing season. The eMODIS system provides current MODIS Terra NDVI products for Alaska. Resulting forest change products were assessed with ground, aerial, and Landsat reference data. When cloud and snow free, these preliminary products appeared to capture regional forest disturbances from insect defoliation and fires; however, more work is needed to mitigate cloud and snow contamination, including integration of eMODIS Aqua data.

  16. Influence of warning information changes on emergency response

    NASA Astrophysics Data System (ADS)

    Heisterkamp, Tobias; Ulbrich, Uwe; Glade, Thomas; Tetzlaff, Gerd

    2014-05-01

    Mitigation and risk reduction of natural hazards is significantly related to the possibility of predicting the actual event. Some hazards can already be forecasted several days in advance. For these hazards, early warning systems have been developed, installed and improved over the years. The formation of winter storms for example can be recognized up to one week before they pass through Central Europe. This relative long early warning time has the advantage that forecasters can concretise the warnings over time. Therefore, warnings can even be adapted to alternating conditions within the process, the observation or changes in its modelling. Emergency managers are one group of warning recipients in the civil protection sector. They have to prepare or initiate prevention or response measures at a specific point of time, depending on the required lead time of the referring actions. At this point of time already, the forecast and its equivalent warning, has to be assumed as a stage of reality, hence the decision-makers have to come to a conclusion. These decisions are based on spatial and temporal knowledge of the forecasted event and the consequential situation of risk. With incoming warning updates, the detailed status of information is permanently being alternated. Consequently, decisions can be influenced by the development of the warning situation and the inherent tendency before a certain point of time. They can also be adapted to updates later on, according to the changing 'decision reality'. The influence of these dynamic hazard situations on operational planning and response by emergency managers is investigated in case studies on winter storms for Berlin, Germany. Therefore, the issued warnings by the weather service and data of operation of Berlin Fire Brigades are analysed and compared. This presentation shows and discusses first results.

  17. An Architecture for Automated Fire Detection Early Warning System Based on Geoprocessing Service Composition

    NASA Astrophysics Data System (ADS)

    Samadzadegan, F.; Saber, M.; Zahmatkesh, H.; Joze Ghazi Khanlou, H.

    2013-09-01

    Rapidly discovering, sharing, integrating and applying geospatial information are key issues in the domain of emergency response and disaster management. Due to the distributed nature of data and processing resources in disaster management, utilizing a Service Oriented Architecture (SOA) to take advantages of workflow of services provides an efficient, flexible and reliable implementations to encounter different hazardous situation. The implementation specification of the Web Processing Service (WPS) has guided geospatial data processing in a Service Oriented Architecture (SOA) platform to become a widely accepted solution for processing remotely sensed data on the web. This paper presents an architecture design based on OGC web services for automated workflow for acquisition, processing remotely sensed data, detecting fire and sending notifications to the authorities. A basic architecture and its building blocks for an automated fire detection early warning system are represented using web-based processing of remote sensing imageries utilizing MODIS data. A composition of WPS processes is proposed as a WPS service to extract fire events from MODIS data. Subsequently, the paper highlights the role of WPS as a middleware interface in the domain of geospatial web service technology that can be used to invoke a large variety of geoprocessing operations and chaining of other web services as an engine of composition. The applicability of proposed architecture by a real world fire event detection and notification use case is evaluated. A GeoPortal client with open-source software was developed to manage data, metadata, processes, and authorities. Investigating feasibility and benefits of proposed framework shows that this framework can be used for wide area of geospatial applications specially disaster management and environmental monitoring.

  18. Using highways for no-notice evacuations : routes to effective evacuation planning primer series.

    DOT National Transportation Integrated Search

    2007-11-01

    The focus of this primer is no-notice events. These no-notice incidents occur for many reasons, such as forest fires, major : storms, chemical spills, or terrorist acts. Their common denominator is that they occur with little or no warning, which pre...

  19. Developing Non-Lethal Weapons: The Human Effects Characterization Process

    DTIC Science & Technology

    2015-06-01

    countered more than a dozen, rock-throwing locals. After a Marine fired a 12 - gauge , non-lethal warning munition, the rock throwers fled. Similarly...extended human electromuscular incapacitation (ef- fects similar to those caused by TASER devices used by law enforcement). However, confidence must be

  20. 78 FR 2618 - Self-Contained Breathing Apparatus Remaining Service-Life Indicator Performance Requirements

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-14

    ... 0920-AA38 Self-Contained Breathing Apparatus Remaining Service-Life Indicator Performance Requirements... requirements for self-contained breathing apparatus (SCBA) remaining service-life indicators or warning devices... self-contained breathing apparatus (SCBA) used in the fire service, and a firefighters' union. A...

  1. Historical telecommunication in the Hindukush-Karakoram-Himalayas: An ancient early warning system for glacier lake outbursts

    NASA Astrophysics Data System (ADS)

    Iturrizaga, Lasafam

    2016-04-01

    Mountain societies are in a crucial transition phase in terms of the management of natural hazards. Advances in geographic technologies, such as a variety of remote-sensing tools and mobile communication systems, have drastically changed the way of early warning methods in difficult accessible high mountain environments compared to those of ancient times. In order to implement new natural hazard policies, it is essential to unravel the traditional ways of disaster management which is presented here by a case study from the Hindukush-Karakoram-Himalayas. In the rugged relief of the Himalaya Region, the exchange of information was a labor-intensive and time-consuming task for remote high mountain villages before the infrastructural development and the introduction of modern communication systems. Therefore, early warning of natural hazards with long run-out distances seems to have been rather impossible. However, in the present study a historical optical long-distance and fast operating communication system over horizontal distances of several hundred kilometers was discovered during field investigations in the Hindukush-Karakoram and the transmission paths reconstructed in the following years. The so called Puberanch-system relied on a chain of fire signals as used by ancient societies in other mountain and coastal environments in the world. It was originally in use for the alert against war attacks from hostile neighboring communities. Later on, it served as an early warning system for glacier lake outbursts, which have been in the end of the 19th century and beginning of the 20th century one of the most devastating natural hazards in the region. Remarkable is the fact that fire posts were located in extremely harsh environments at altitudes above 4000 m requiring a highly sophisticated supply system of fire wood and food. Interviews with local inhabitants, the evaluation of historical travel records and international newspapers proved, that the system has been operated in the entire Hindukush-Karakoram Region including Ladakh. The locations of selected signal fire signal chains have been reconstructed for the Valleys of Shimshal, Karambar and Rupal. Natural hazard management is increasingly dominated by external technological and cost-intensive approaches in the Himalayas. Local traditional knowledge and practical expertise may be given up without an alternative plan for hazard management. Thus, the intervention from external side in traditional mountain societies and the implementation of distinct security expectations has to be well considered at the long-term.

  2. Bullet fragmentation preceding a contour shot: case study and experimental simulation.

    PubMed

    Sterzik, V; Kneubuehl, B P; Bohnert, M; Riva, F; Glardon, M

    2017-01-01

    In medico-legal literature, only a small number of publications deal with lethal injuries caused by shots with modified guns. This might lead to the conclusion that such cases are extremely rare. However, there are cases again and yet again. During the investigation process, the modified gun is of particular importance since it can show an unusual ballistic behaviour. The present paper reports on a suicide of a 60-year-old man, committed with a modified revolver and a lead bullet. The man had a single gunshot wound with entrance at the right temporal bone. Autopsy revealed that the bullet had fragmented into two major parts. The smaller one stood outside the cranial cavity and pushed its way alongside between the cranial bone and scalp to its end position in the left temporal area. The bigger part entered the cranial cavity and ended in the left parietal lobe. In shots on ballistic soap and on a head-model, the ballistics of the weapon and lead bullet were characterized. The angle necessary for bullet fragmentation was determined by shots on ballistic soap and turned out to be 55°-60° at a velocity of around 200 m/s. This knowledge was transferred to contact shots on a head-model consisting of a layered polyurethane sphere filled with 10 % ballistic gelatine and covered with a skin-like cap almost all around. The resulting injury pattern corresponded to the one of the suicide person. The bigger bullet part entered the skull while the smaller part pushed its way alongside between skin and skull causing an outer contour shot. Furthermore, the revolver was documented firing off two bullets by one trigger pull-a phenomenon of importance for forensic casework the authors have not found reported in forensic literature.

  3. Smoke alarms in the home: what every physician should know

    PubMed Central

    Sultan, Mohammed A.; Feldman, William M.

    1985-01-01

    Primary care physicians interested in health education and accident prevention should be knowledgeable about smoke alarms (smoke detectors with built-in alarms). Either ionization or photoelectric smoke alarms can help save lives if they are properly installed and maintained. The number, site and maintenance of smoke alarms in the home and the steps a person should take in the event of a fire are discussed. Considering the rates of death, disability and disfigurement associated with residential fires, early warning devices such as smoke alarms make sense. PMID:4063931

  4. Emergency assessments of postfire debris-flow hazards for the 2009 La Brea, Jesusita, Guiberson, Morris, Sheep, Oak Glen, Pendleton, and Cottonwood fires in southern California

    USGS Publications Warehouse

    Cannon, Susan H.; Gartner, Joseph E.; Rupert, Michael G.; Michael, John A.

    2010-01-01

    This report presents an emergency assessment of potential debris-flow hazards from basins burned by the 2009 La Brea and Jesusita fires in Santa Barbara County, the Guiberson fire in Ventura County, the Morris fire in Los Angeles County, the Sheep, Oak Glen, and Pendleton fires in San Bernardino County, and the Cottonwood fire in Riverside County, southern California. Statistical-empirical models developed to analyze postfire debris flows are used to estimate the probability and volume of debris-flows produced from drainage basins within each of the burned areas. Debris-flow probabilities and volumes are estimated as functions of different measures of basin burned extent, gradient, and material properties in response to both a 3-hour-duration, 2-year-recurrence thunderstorm and to a widespread, 12-hour-duration, 2-year-recurrence winter storm. This assessment provides critical information for issuing warnings, locating and designing mitigation measures, and planning evacuation timing and routes within the first two winters following the fire.

  5. Muzzle-loading weapons discharging spherical lead bullets: two case studies and experimental simulation using a skin-soap composite model.

    PubMed

    Große Perdekamp, Markus; Braunwarth, Roland; Kromeier, Jan; Nadjem, Hadi; Pollak, Stefan; Thierauf, Annette

    2013-07-01

    In current forensic practice, fatal injuries from black powder guns are rare events. In contact and close-range shots, the intensity of GSR deposition (soot, powder particles) is much greater than that in shots with smokeless powder ammunition. The same applies to any burning effects from the combustion gases. Besides, a wad of felt interposed between the propellant and the lead bullet may enter the wound channel. Apart from these findings seen in close-range shots, another characteristic feature results from the mostly spherical shape of the missiles causing maximum tissue damage at the entrance site. Two fatal injuries inflicted with muzzle-loading weapons are reported. In the first case, suicide was committed with a cal. 11.6 mm miniature cannon by firing a contact shot to the back of the neck. In test shots using black powder (1 and 2 g) as propellant, the mean bullet velocity measured 1 m away from the weapon was 87.11 and 146.85 m/s, respectively, corresponding to a kinetic energy of 32.49 and 92.95 J, respectively. Contact test shots to composite models consisting of ballistic soap covered by pig skin at the entrance site were evaluated by CT and revealed cone-like cavitations along the bullet path as known from spherical missiles and penetration depths up to 25 cm. The second case presented deals with a homicidal close-range shot discharged from a muzzle-loading percussion pistol cal. .44. The skin around the entrance site (root of the nose) was densely covered with blackish soot and powder particles, whereas the eyebrows and eyelashes showed singeing of the hairs. The flattened bullet and the wad had got stuck under the scalp of the occipital region. In both cases, there was a disproportionally large zone of tissue destruction in the initial parts of the wound tracks.

  6. Laser-induced incandescence measurements of soot in turbulent pool fires.

    PubMed

    Frederickson, Kraig; Kearney, Sean P; Grasser, Thomas W

    2011-02-01

    We present what we believe to be the first application of the laser-induced incandescence (LII) technique to large-scale fire testing. The construction of an LII instrument for fire measurements is presented in detail. Soot volume fraction imaging from 2 m diameter pool fires burning blended toluene/methanol liquid fuels is demonstrated along with a detailed report of measurement uncertainty in the challenging pool fire environment. Our LII instrument relies upon remotely located laser, optical, and detection systems and the insertion of water-cooled, fiber-bundle-coupled collection optics into the fire plume. Calibration of the instrument was performed using an ethylene/air laminar diffusion flame produced by a Santoro-type burner, which allowed for the extraction of absolute soot volume fractions from the LII images. Single-laser-shot two-dimensional images of the soot layer structure are presented with very high volumetric spatial resolution of the order of 10(-5) cm3. Probability density functions of the soot volume fraction fluctuations are constructed from the large LII image ensembles. The results illustrate a highly intermittent soot fluctuation field with potentially large macroscale soot structures and clipped soot probability densities.

  7. Density Deconvolution With EPI Splines

    DTIC Science & Technology

    2015-09-01

    effects of various substances on test subjects [11], [12]. Whereas in geophysics, a shot may be fired into the ground, in pharmacokinetics, a signal is...be significant, including medicine, bioinformatics, chemistry, as- tronomy, and econometrics , as well as an extensive review of kernel based methods...demonstrate the effectiveness of our model in simulations motivated by test instances in [32]. We consider an additive measurement model scenario where

  8. Women in Combat: Issues for Congress

    DTIC Science & Technology

    2015-12-03

    report suggested that these changes might have the benefit of expanding career opportunities for women, while increasing flexibility for field...Squad Assessment Tasks Day 1:  Hike 1 kilometer uphill with 28-pound assault pack and personal weapon.  Scramble over 8-foot shipping container...Allow engineers to move forward and fire two breaching shots with Bangalore torpedoes. Day 2:  Hike 7 kilometers with weapons and 59-pound

  9. Burn rates of TiH2/KClO4/Viton and output testing of NASA SKD26100098-301 pressure cartridges

    NASA Technical Reports Server (NTRS)

    Holy, John A.

    1993-01-01

    The burn rates of the pyrotechnic TiH2/KClO4/Viton with a mass ratio of 30/65/5 have been measured as a function of pressure in nitrogen up to 312 MPa(45 Kpsi). The burn rates were fit to R = a pn, with a = 2.055 cm/sec/MPan and n = 0.472 between 0.15 MPa (22 psi) and 21.6 MPa (3.13 Kpsi) and a = 4.38 cm/sec/MPan and n = 0.266 between 70 MPa (10.15 Kpsi) and 312 MPa (45.25 Kpsi). The decrease in slope at the higher pressures is attributed to a diffusion limited reaction. No acoustically driven flame instabilities or large conductive-to-convective burn transitions were observed. Solid reaction products were analyzed by x-ray diffraction and scanning electron microscopy (SEM). X-ray diffraction detected only TiO2 and KC1. SEM showed that the particle size of the reaction products increased as the nitrogen pressure increased. There were no anomalous characteristics of the burn of this pyrotechnic that could be interpreted as a cause of the o-ring blow-by problem in the forward shear bolt assembly. Three NASA SKD26100098-301 pressure cartridges were fired into a fixed volume vessel that was sealed with an O-ring. A maximum pressure of 181.7 MPa(26,350 psi) was reached in around 100 ,mu sec for two shots fired into a volume of 16.3 cm3(0.996 in3). A maximum pressure of 33,460 psi was reached for one shot fired into a volume of 9.55 cm3(0.583 in3). The O-ring burned through on one shot in the larger volume and leaked on the other two thereby simulating the effects of an O-ring leak. The results imply that the piston in the shear bolt assembly would receive a large impulse even if there was a leak in an O-ring seal.

  10. Survival of fossils under extreme shocks induced by hypervelocity impacts.

    PubMed

    Burchell, M J; McDermott, K H; Price, M C; Yolland, L J

    2014-08-28

    Experimental data are shown for survival of fossilized diatoms undergoing shocks in the GPa range. The results were obtained from hypervelocity impact experiments which fired fossilized diatoms frozen in ice into water targets. After the shots, the material recovered from the target water was inspected for diatom fossils. Nine shots were carried out, at speeds from 0.388 to 5.34 km s(-1), corresponding to mean peak pressures of 0.2-19 GPa. In all cases, fragmented fossilized diatoms were recovered, but both the mean and the maximum fragment size decreased with increasing impact speed and hence peak pressure. Examples of intact diatoms were found after the impacts, even in some of the higher speed shots, but their frequency and size decreased significantly at the higher speeds. This is the first demonstration that fossils can survive and be transferred from projectile to target in hypervelocity impacts, implying that it is possible that, as suggested by other authors, terrestrial rocks ejected from the Earth by giant impacts from space, and which then strike the Moon, may successfully transfer terrestrial fossils to the Moon.

  11. Lethal hypothermia after firing a suicidal shot to the head in a car.

    PubMed

    Ortmann, Jan; Doberentz, Elke; Kernbach-Wighton, Gerhard; Madea, Burkhard

    2016-11-01

    In suicide cases involving an automobile, the car is mostly used as a tool/instrument for the suicide (intoxication by exhaust fumes, crash against solid objects such as a pylon). However, a car is uncommonly also used only as the location for a suicide. In the present case, a 70-year-old man had been found dead on the passenger seat of his car. According to witnesses, the car had not been parked there at the same time of the previous day. During that period, the weather had been dry, with temperatures ranging from -1⁰ C at night to +5⁰ C during the day. The man had shot himself with a small-caliber revolver (so-called bulldog-revolver) almost horizontally in the left temple (transtemporal shot through the frontal lobes). Obviously, the suicide had retained the capability to act at least for a short time, as the revolver was found under his left bottom. As morphological signs of prolonged agony some findings of hypothermia were observed (e. g. Wischnewski spots of the stomach).

  12. Survival of fossils under extreme shocks induced by hypervelocity impacts

    PubMed Central

    Burchell, M. J.; McDermott, K. H.; Price, M. C.; Yolland, L. J.

    2014-01-01

    Experimental data are shown for survival of fossilized diatoms undergoing shocks in the GPa range. The results were obtained from hypervelocity impact experiments which fired fossilized diatoms frozen in ice into water targets. After the shots, the material recovered from the target water was inspected for diatom fossils. Nine shots were carried out, at speeds from 0.388 to 5.34 km s−1, corresponding to mean peak pressures of 0.2–19 GPa. In all cases, fragmented fossilized diatoms were recovered, but both the mean and the maximum fragment size decreased with increasing impact speed and hence peak pressure. Examples of intact diatoms were found after the impacts, even in some of the higher speed shots, but their frequency and size decreased significantly at the higher speeds. This is the first demonstration that fossils can survive and be transferred from projectile to target in hypervelocity impacts, implying that it is possible that, as suggested by other authors, terrestrial rocks ejected from the Earth by giant impacts from space, and which then strike the Moon, may successfully transfer terrestrial fossils to the Moon. PMID:25071234

  13. Investigating Over Critical Thresholds of Forest Megafires Danger Conditions in Europe Utilising the ECMWF ERA-Interim Reanalysis

    NASA Astrophysics Data System (ADS)

    Petroliagkis, Thomas I.; Camia, Andrea; Liberta, Giorgio; Durrant, Tracy; Pappenberger, Florian; San-Miguel-Ayanz, Jesus

    2014-05-01

    The European Forest Fire Information System (EFFIS) has been established by the Joint Research Centre (JRC) and the Directorate General for Environment (DG ENV) of the European Commission (EC) to support the services in charge of the protection of forests against fires in the EU and neighbour countries, and also to provide the EC services and the European Parliament with information on forest fires in Europe. Within its applications, EFFIS provides current and forecast meteorological fire danger maps up to 6 days. Weather plays a key role in affecting wildfire occurrence and behaviour. Meteorological parameters can be used to derive meteorological fire weather indices that provide estimations of fire danger level at a given time over a specified area of interest. In this work, we investigate the suitability of critical thresholds of fire danger to provide an early warning for megafires (fires > 500 ha) over Europe. Past trends of fire danger are analysed computing daily fire danger from weather data taken from re-analysis fields for a period of 31 years (1980 to 2010). Re-analysis global data sets coming from the construction of high-quality climate records, which combine past observations collected from many different observing and measuring platforms, are capable of describing how Fire Danger Indices have evolved over time at a global scale. The latest and most updated ERA-Interim dataset of the European Centre for Medium-Range Weather Forecast (ECMWF) was used to extract meteorological variables needed to compute daily values of the Canadian Fire Weather Index (CFWI) over Europe, with a horizontal resolution of about 75x75 km. Daily time series of CFWI were constructed and analysed over a total of 1,071 European NUTS3 centroids, resulting in a set of percentiles and critical thresholds. Such percentiles could be used as thresholds to help fire services establish a measure of the significance of CFWI outputs as they relate to levels of fire potential, fuel conditions and fire danger. Median percentile values of fire days accumulated over the 31-year period were compared to median values of all days from that period. As expected, the CWFI time series exhibit different values on fire days than on all days. In addition, a percentile analysis was performed in order to determine the behaviour of index values corresponding to fire events falling into the megafire category. This analysis resulted in a set of critical thresholds based on percentiles. By utilising such thresholds, an initial framework of an early warning system has being established. By lowering the value of any of these thresholds, the number of hits could be increased until all extremes were captured (resulting in zero misses). However, in doing so, the number of false alarms tends to increase significantly. Consequently, an optimal trade-off between hits and false alarms has to be established when setting different (critical) CFWI thresholds.

  14. Chronic Lead Intoxication From Eating Wild-Harvested Game.

    PubMed

    Buenz, Eric J; Parry, Gareth J

    2018-05-01

    The purpose of this article is to determine if conversion from eating wild game harvested with lead-based ammunition to nonlead-based ammunition results in lower blood lead levels. Supersonic injection of toxin-leeching frangible projectiles into food is intuitively bad. As much as 95% of the ~13.7 million hunters in the United States choose shrapnel-inducing lead bullets to kill game; in addition, not harvesting meat is an incarcerable crime. A lead ammunition ban on certain federal lands was recently rescinded and the National Rifle Association refutes any risk from eating lead bullet-harvested game. A patient subsisting solely on lead-shot meat was converted to non-lead ammunition and his blood lead level tracked. Concomitant with his conversion to nonlead ammunition, a controlled experiment was performed using the patient's bullets to determine his daily lead intake from lead-shot meat. While eating lead-shot meat, the patient was consuming 259.3 ± 235.6 µg of lead daily and his blood lead level was 74.7 µg/dL. Conversion to nonlead ammunition was associated with a reduced blood lead level. Unsafe blood lead levels can occur from eating game harvested with lead ammunition. Physicians should warn hunting patients of this potential risk and counsel them about the availability of nonlead ammunition alternatives. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Time-jittered marine seismic data acquisition via compressed sensing and sparsity-promoting wavefield reconstruction

    NASA Astrophysics Data System (ADS)

    Wason, H.; Herrmann, F. J.; Kumar, R.

    2016-12-01

    Current efforts towards dense shot (or receiver) sampling and full azimuthal coverage to produce high resolution images have led to the deployment of multiple source vessels (or streamers) across marine survey areas. Densely sampled marine seismic data acquisition, however, is expensive, and hence necessitates the adoption of sampling schemes that save acquisition costs and time. Compressed sensing is a sampling paradigm that aims to reconstruct a signal--that is sparse or compressible in some transform domain--from relatively fewer measurements than required by the Nyquist sampling criteria. Leveraging ideas from the field of compressed sensing, we show how marine seismic acquisition can be setup as a compressed sensing problem. A step ahead from multi-source seismic acquisition is simultaneous source acquisition--an emerging technology that is stimulating both geophysical research and commercial efforts--where multiple source arrays/vessels fire shots simultaneously resulting in better coverage in marine surveys. Following the design principles of compressed sensing, we propose a pragmatic simultaneous time-jittered time-compressed marine acquisition scheme where single or multiple source vessels sail across an ocean-bottom array firing airguns at jittered times and source locations, resulting in better spatial sampling and speedup acquisition. Our acquisition is low cost since our measurements are subsampled. Simultaneous source acquisition generates data with overlapping shot records, which need to be separated for further processing. We can significantly impact the reconstruction quality of conventional seismic data from jittered data and demonstrate successful recovery by sparsity promotion. In contrast to random (sub)sampling, acquisition via jittered (sub)sampling helps in controlling the maximum gap size, which is a practical requirement of wavefield reconstruction with localized sparsifying transforms. We illustrate our results with simulations of simultaneous time-jittered marine acquisition for 2D and 3D ocean-bottom cable survey.

  16. Alcohol skin preparation causes surgical fires

    PubMed Central

    Rocos, B; Donaldson, LJ

    2012-01-01

    INTRODUCTION Surgical fires are a rare but serious preventable safety risk in modern hospitals. Data from the US show that up to 650 surgical fires occur each year, with up to 5% causing death or serious harm. This study used the National Reporting and Learning Service (NRLS) database at the National Patient Safety Agency to explore whether spirit-based surgical skin preparation fluid contributes to the cause of surgical fires. METHODS The NRLS database was interrogated for all incidents of surgical fires reported between 1 March 2004 and 1 March 2011. Each report was scrutinised manually to discover the cause of the fire. RESULTS Thirteen surgical fires were reported during the study period. Of these, 11 were found to be directly related to spirit-based surgical skin preparation or preparation soaked swabs and drapes. CONCLUSIONS Despite manufacturer's instructions and warnings, surgical fires continue to occur. Guidance published in the UK and US states that spirit-based skin preparation solutions should continue to be used but sets out some precautions. It may be that fire risk should be included in pre-surgical World Health Organization checklists or in the surgical training curriculum. Surgical staff should be aware of the risk that spirit-based skin preparation fluids pose and should take action to minimise the chance of fire occurring. PMID:22391366

  17. Alcohol skin preparation causes surgical fires.

    PubMed

    Rocos, B; Donaldson, L J

    2012-03-01

    Surgical fires are a rare but serious preventable safety risk in modern hospitals. Data from the US show that up to 650 surgical fires occur each year, with up to 5% causing death or serious harm. This study used the National Reporting and Learning Service (NRLS) database at the National Patient Safety Agency to explore whether spirit-based surgical skin preparation fluid contributes to the cause of surgical fires. The NRLS database was interrogated for all incidents of surgical fires reported between 1 March 2004 and 1 March 2011. Each report was scrutinised manually to discover the cause of the fire. Thirteen surgical fires were reported during the study period. Of these, 11 were found to be directly related to spirit-based surgical skin preparation or preparation soaked swabs and drapes. Despite manufacturer's instructions and warnings, surgical fires continue to occur. Guidance published in the UK and US states that spirit-based skin preparation solutions should continue to be used but sets out some precautions. It may be that fire risk should be included in pre-surgical World Health Organization checklists or in the surgical training curriculum. Surgical staff should be aware of the risk that spirit-based skin preparation fluids pose and should take action to minimise the chance of fire occurring.

  18. Model gives a 3-month warning of Amazonian forest fires

    NASA Astrophysics Data System (ADS)

    Schultz, Colin

    2011-08-01

    The widespread drought suffered by the Amazon rain forest in the summer of 2005 was heralded at the time as the drought of the century. Because of the dehydrated conditions, supplemented by slash and burn agricultural practices, the drought led to widespread forest fires throughout the western Amazon, a portion of the rain forest usually too lush to support spreading wildfires. Only 5 years later, the 2005 season was outdone by even more widespread drought, with fires decimating more than 3000 square kilometers of western Amazonian rain forest. Blame for the wildfires has been consistently laid on deforestation and agricultural practices, but a convincing climatological explanation exists as well. (Geophysical Research Letters, doi:10.1029/2011GL047392, 2011)

  19. Credit PSR. The flammable waste materials shed appears as seen ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit PSR. The flammable waste materials shed appears as seen when looking south (186°) from South Liquid Loop Road. Note the catch basin for retaining accidentally spilled substances. Wastes are stored in drums and other safety containers until disposal by burning at the Incinerator (4249/E-50) or by other means. Note the nearby sign warning of corrosive, flammable materials, and calling attention to a fire extinguisher; a telephone is provided to call for assistance in the event of an emergency. This structure is isolated to prevent the spread of fire, and it is lightly built so damage from a fire will be inexpensive to repair - Jet Propulsion Laboratory Edwards Facility, Waste Flammable Storage Building, Edwards Air Force Base, Boron, Kern County, CA

  20. Kuwait Oil Fires, Kuwait

    NASA Image and Video Library

    1991-05-06

    STS039-72-060 (28 April-6 May 1991) --- This view from the Earth-orbiting Space Shuttle Discovery shows the smoke from burning oil well fires, aftermath of Iraqi occupation. Oil wells to the north of the Bay of Kuwait and just south of Kuwait City, on the south shore, can be seen burning out of control. Compared with pictures of the same area shot during STS-37 (April 1991), this frame shows a complete shift of winds, with much of the smoke blowing eastward over the Gulf. The STS-37 scenes showed lengthy southward-blowing sheets of smoke toward Saudi Arabia. In this view, the Gulf island Faylakah Awhah is barely visible through the smoke.

  1. Magazine Influence on Cartridge Case Ejection Patterns with Glock Pistols.

    PubMed

    Kerkhoff, Wim; Alberink, Ivo; Mattijssen, Erwin J A T

    2018-01-01

    In this study, the cartridge case ejection patterns of six different Glock model pistols (one specimen per model) were compared under three conditions: firing with a loaded magazine, an empty magazine, and without magazine. The distances, covered by the ejected cartridge cases given these three conditions, were compared for each of the six models. A significant difference was found between the groups of data for each of the tested specimens. This indicates that it is important that, to reconstruct a shooting scene incident based on the ejection patterns of a pistol, test shots are fired with the same pistol type and under the correct magazine condition. © 2017 American Academy of Forensic Sciences.

  2. Australia fires and burn scars as seen from STS-62

    NASA Image and Video Library

    1994-03-05

    STS062-106-042 (4-18 March 1994) --- This view of southern Australia about 100 miles northwest of Melbourne shows areas of protected reserves of natural forests in the midst of agricultural crop lands. The green patch seen here has been recently burned as indicated by the irregular large scar. The impact of winds on the scar is clearly visible. This nature preserve is reported to be the home to a large number of animals including the koala bears. Similar views were shot by the STS-60 crewmembers last month. These photographs will assist earth scientists in mapping the impact of forest fires and in moniotring the recovery of burned areas.

  3. FLIRE DSS: A web tool for the management of floods and wildfires in urban and periurban areas

    NASA Astrophysics Data System (ADS)

    Kochilakis, Giorgos; Poursanidis, Dimitris; Chrysoulakis, Nektarios; Varella, Vassiliki; Kotroni, Vassiliki; Eftychidis, Giorgos; Lagouvardos, Kostas; Papathanasiou, Chrysoula; Karavokyros, George; Aivazoglou, Maria; Makropoulos, Christos; Mimikou, Maria

    2016-01-01

    A web-based Decision Support System, named FLIRE DSS, for combined forest fire control and planning as well as flood risk management, has been developed and is presented in this paper. State of the art tools and models have been used in order to enable Civil Protection agencies and local stakeholders to take advantage of the web based DSS without the need of local installation of complex software and their maintenance. Civil protection agencies can predict the behavior of a fire event using real time data and in such a way plan its efficient elimination. Also, during dry periods, agencies can implement "what-if" scenarios for areas that are prone to fire and thus have available plans for forest fire management in case such scenarios occur. Flood services include flood maps and flood-related warnings and become available to relevant authorities for visualization and further analysis on a daily basis. When flood warnings are issued, relevant authorities may proceed to efficient evacuation planning for the areas that are likely to flood and thus save human lives. Real-time weather data from ground stations provide the necessary inputs for the calculation of the fire model in real-time, and a high resolution weather forecast grid supports flood modeling as well as the development of "what-if" scenarios for the fire modeling. All these can be accessed by various computer sources including PC, laptop, Smartphone and tablet either by normal network connection or by using 3G and 4G cellular network. The latter is important for the accessibility of the FLIRE DSS during firefighting or rescue operations during flood events. All these methods and tools provide the end users with the necessary information to design an operational plan for the elimination of the fire events and the efficient management of the flood events in almost real time. Concluding, the FLIRE DSS can be easily transferred to other areas with similar characteristics due to its robust architecture and its flexibility.

  4. [The possibilities for determining the shooting distance by means of inductively coupled plasma optical emission spectrometry].

    PubMed

    Svetlolobov, D Yu; Luzanova, I S; Zorin, Yu V; Makarov, I Yu; Lorents, A S

    The objective of the present study was to evaluate the possibilities for determining the shooting distance for the MR-79-9 Makarych non-lethal pistol (diameter 9 mm, rubber bullet, shot energy 50 J) by means of inductively coupled plasma optical emission spectrometry. The experiments were carried under the conditions of a ballistic shooting range making the shots from a distance of 0 to 120 cm. The 15×15 cm pieces of muslin fabric and biomaterials (leather) were used as the targets. The morphological signs of the damages inflicted to the targets were evaluated either with the unassisted eye, a criminalistical magnifying glass or the SMT-4 binocular stereoscopic microscope (Germany). The shot products, the area and boundaries of their dispersion were determined in reflected IR and filtered UV rays. Inductively coupled plasma optical emission spectrometry was applied for the qualitative and quantitative analysis of various shot products from the entry hole zone with the contamination (wipedown) bands and contusion collars being 0.2-0.5 cm (group 1) and 2-3 cm (group 2) in width, with special reference to the identification of Ba, Cu, Cr, Fe, K, Ni, Pb, Sb, Sn and Zn. The results of the study give evidence that the detection of Ba, Pb, and Sb among the products of a shot fired from the MR-79-9 Makarych non-lethal pistol is of especially high informative value for determining the shooting distance whereas the detection of Cr, K, Sn and Ni is of a minimum value for this purpose.

  5. Synaptic shot noise and conductance fluctuations affect the membrane voltage with equal significance.

    PubMed

    Richardson, Magnus J E; Gerstner, Wulfram

    2005-04-01

    The subthreshold membrane voltage of a neuron in active cortical tissue is a fluctuating quantity with a distribution that reflects the firing statistics of the presynaptic population. It was recently found that conductance-based synaptic drive can lead to distributions with a significant skew. Here it is demonstrated that the underlying shot noise caused by Poissonian spike arrival also skews the membrane distribution, but in the opposite sense. Using a perturbative method, we analyze the effects of shot noise on the distribution of synaptic conductances and calculate the consequent voltage distribution. To first order in the perturbation theory, the voltage distribution is a gaussian modulated by a prefactor that captures the skew. The gaussian component is identical to distributions derived using current-based models with an effective membrane time constant. The well-known effective-time-constant approximation can therefore be identified as the leading-order solution to the full conductance-based model. The higher-order modulatory prefactor containing the skew comprises terms due to both shot noise and conductance fluctuations. The diffusion approximation misses these shot-noise effects implying that analytical approaches such as the Fokker-Planck equation or simulation with filtered white noise cannot be used to improve on the gaussian approximation. It is further demonstrated that quantities used for fitting theory to experiment, such as the voltage mean and variance, are robust against these non-Gaussian effects. The effective-time-constant approximation is therefore relevant to experiment and provides a simple analytic base on which other pertinent biological details may be added.

  6. Aeronautics and Space Highlights [1979 Highlights

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The videotape includes footage of the following: Voyagers to Jupiter, Pioneer to Saturn, High Energy Astronomy Observatory, space telescope, space shuttle, astronauts Young and Crippen, 10th anniversary of Apollo 11, Skylab reentry, Landsat, satellite freeze warning, Fire Fighting Module, SAGE, wind generators, Solar Energy Project, electric car research, XV-15, HiMAT, and crash worthiness tests.

  7. 77 FR 58081 - Protection of Stratospheric Ozone: Listing of Substitutes for Ozone-Depleting Substances-Fire...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-19

    ... protection options including new, improved technology for early warning and smoke detection. Thus, EPA is... require state, local, or tribal governments to change their regulations. Thus, Executive Order 13132 does... governments to change their regulations. Thus, Executive Order 13175 does not apply to this action. G...

  8. 49 CFR 393.95 - Emergency equipment on all power units.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Standard No. 125, § 571.125 of this title; or (2) At least 6 fusees or 3 liquid-burning flares. The vehicle... relative to the motor vehicle. (5) Extinguishing agents. The fire extinguisher must use an extinguishing... for those parts and accessories. (c)-(e) [Reserved] (f) Warning devices for stopped vehicles. Except...

  9. 49 CFR 393.95 - Emergency equipment on all power units.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Standard No. 125, § 571.125 of this title; or (2) At least 6 fusees or 3 liquid-burning flares. The vehicle... relative to the motor vehicle. (5) Extinguishing agents. The fire extinguisher must use an extinguishing... for those parts and accessories. (c)-(e) [Reserved] (f) Warning devices for stopped vehicles. Except...

  10. Diesel oil pool fire characteristic under natural ventilation conditions in tunnels with roof openings.

    PubMed

    Wang, Yanfu; Jiang, Juncheng; Zhu, Dezhi

    2009-07-15

    In order to research the fire characteristic under natural ventilation conditions in tunnels with roof openings, full-scale experiment of tunnel fire is designed and conducted. All the experimental data presented in this paper can be further applied for validation of numerical simulation models and reduced-scale experimental results. The physical model of tunnel with roof openings and the mathematical model of tunnel fire are presented in this paper. The tunnel fire under the same conditions as experiment is simulated using CFD software. From the results, it can be seen that most smoke is discharged directly off the tunnel through roof openings, so roof openings are favorable for exhausting smoke. But along with the decrease of smoke temperatures, some smoke may backflow and mix with the smoke-free layer below, which leads to fall in visibility and is unfavorable for personnel evacuation. So it is necessary to research more efficient ways for improving the smoke removal efficiency, such as early fire detection systems, adequate warning signs and setting tunnel cap.

  11. [The modeling of the ricochet shot fired from a light weapon].

    PubMed

    Gusentsov, A O; Chuchko, V A; Kil'dyushev, E M; Tumanov, E V

    The objective of the present study was to choose the optimal method for the modeling of the glance of a bullet after hitting a target under conditions of the laboratory experiment. The study required the designing and construction of an original device for the modeling of the rebound effect of a light-firearm shot under experimental conditions. The device was tested under conditions of the laboratory experiment. The trials have demonstrated the possibility of using barriers of different weight and dimensions in the above device, their positioning and fixation depending on the purpose of the experiment, dynamic alteration of its conditions with due regard for the safety and security arrangements to protect the health and life of the experimenters without compromising the statistical significance and scientific validity of the results of the experiments.

  12. Focusing experiments in plasma coaxial railguns

    NASA Astrophysics Data System (ADS)

    Driga, M. D.; Cook, R. W.; Thelen, R. F.

    1986-11-01

    Results are reported from experiments on focusing of plasma fired from a coaxial electromagnetic gun (CEMG). The plasma used, obtained by exploding a metallic fuse at the gun breech, comprised metal vapor, metallic liquid droplets and small chunks of solid metal. An azimuthal current, and thereby an axial field, was introduced at the breech of the CEMG by a solenoid. Previous studies indicated that the field would cause vaporized metal to form into a self-stabilizing toroidal plasma. Test shots instrumented with Languir probes and pick-up coils did not reveal the presence of toroidal plasma rings. However, post-mortem of the 30 cm rail showed that only one-third of the 3 mg Al fuse metal remained in the bore. Further, a toroidal hole was punched in a diagnostic screen at the bore exit after one shot.

  13. Information Framework of Pervasive Real Time Monitoring System: Case of Peat Land Forest Fires and Air Quality in South Sumatera, Indonesia

    NASA Astrophysics Data System (ADS)

    Nurmaini, Siti; Firsandaya Malik, Reza; Stiawan, Deris; Firdaus; Saparudin; Tutuko, Bambang

    2017-04-01

    The information framework aims to holistically address the problems and issues posed by unwanted peat and land fires within the context of the natural environment and socio-economic systems. Informed decisions on planning and allocation of resources can only be made by understanding the landscape. Therefore, information on fire history and air quality impacts must be collected for future analysis. This paper proposes strategic framework based on technology approach with data fusion strategy to produce the data analysis about peat land fires and air quality management in in South Sumatera. The research framework should use the knowledge, experience and data from the previous fire seasons to review, improve and refine the strategies and monitor their effectiveness for the next fire season. Communicating effectively with communities and the public and private sectors in remote and rural landscapes is important, by using smartphones and mobile applications. Tools such as one-stop information based on web applications, to obtain information such as early warning to send and receive fire alerts, could be developed and promoted so that all stakeholders can share important information with each other.

  14. Evaluation of detection and response times of fire sensors using an atmospheric monitoring system

    PubMed Central

    Rowland, J.H.; Litton, C.D.; Thomas, R.A.

    2017-01-01

    Atmospheric monitoring systems (AMS) are required when using air from conveyor belt entries to ventilate working sections in U.S. underground coal mines. AMS technology has the potential to increase fire safety mine-wide, but research is needed to determine the detection and response times for fires of a variety of combustible materials. To evaluate the potential of an AMS for fire detection in other areas of a coal mine, a series of full-scale fire experiments were conducted to determine detection and response times from fires of different combustible materials that are found in U.S. underground coal mines, including high- and low-volatility coals, conveyor belts, brattice materials, different types of wood, diesel fuel, and a foam sealant. These experiments were conducted in the Safety Research Coal Mine (SRCM) of the U.S. National Institute for Occupational Safety and Health (NIOSH) located in Pittsburgh, PA, using a commercially available AMS that is typical of current technology. The results showed that through proper selection of sensors and their locations, a mine-wide AMS can provide sufficient early fire warning times and improve the health and safety of miners. PMID:28529442

  15. Evaluation of detection and response times of fire sensors using an atmospheric monitoring system.

    PubMed

    Rowland, J H; Litton, C D; Thomas, R A

    2016-01-01

    Atmospheric monitoring systems (AMS) are required when using air from conveyor belt entries to ventilate working sections in U.S. underground coal mines. AMS technology has the potential to increase fire safety mine-wide, but research is needed to determine the detection and response times for fires of a variety of combustible materials. To evaluate the potential of an AMS for fire detection in other areas of a coal mine, a series of full-scale fire experiments were conducted to determine detection and response times from fires of different combustible materials that are found in U.S. underground coal mines, including high- and low-volatility coals, conveyor belts, brattice materials, different types of wood, diesel fuel, and a foam sealant. These experiments were conducted in the Safety Research Coal Mine (SRCM) of the U.S. National Institute for Occupational Safety and Health (NIOSH) located in Pittsburgh, PA, using a commercially available AMS that is typical of current technology. The results showed that through proper selection of sensors and their locations, a mine-wide AMS can provide sufficient early fire warning times and improve the health and safety of miners.

  16. Emergency assessment of postwildfire debris-flow hazards for the 2011 Motor Fire, Sierra and Stanislaus National Forests, California

    USGS Publications Warehouse

    Cannon, Susan H.; Michael, John A.

    2011-01-01

    This report presents an emergency assessment of potential debris-flow hazards from basins burned by the 2011 Motor fire in the Sierra and Stanislaus National Forests, Calif. Statistical-empirical models are used to estimate the probability and volume of debris flows that may be produced from burned drainage basins as a function of different measures of basin burned extent, gradient, and soil physical properties, and in response to a 30-minute-duration, 10-year-recurrence rainstorm. Debris-flow probability and volume estimates are then combined to form a relative hazard ranking for each basin. This assessment provides critical information for issuing warnings, locating and designing mitigation measures, and planning evacuation timing and routes within the first two years following the fire.

  17. Hostile fire indicator threat data collection for helicopter-mounted applications

    NASA Astrophysics Data System (ADS)

    Naz, P.; Hengy, S.; De Mezzo, S.

    2013-05-01

    This paper briefly describes the set-up of the sensors and the instrumentation deployed by the French-German Research Institute of Saint-Louis (ISL) during the last NATO/ACG3/SG2 HFI Threat Data Collection (Trial PROTEUS which has been conducted during the summer 2012 in Slovenia). The main purpose of this trial was the measurements of weapon and ammunition signatures for threat warning and hostile fire indicator (HFI) system development. The used weapons vary from small caliber rifles to anti-tank rockets in ground-to-ground shooting configurations. For the ISL team, the objectives consisted in measuring the acoustic signals for detection and localization of weapon firing events. Experimental results of sound localization obtained by using ground based sensors are presented and analyzed under various conditions.

  18. Case-study of fatal gunshot wounds from non-lethal projectiles.

    PubMed

    Chowaniec, Czesław; Kobek, Mariusz; Jabłoński, Christian; Kabiesz-Neniczka, Stanisława; Karczewska, Weronika

    2008-07-04

    The authors present a case of the death of a 60-year-old man shot using rubber projectiles that were fired by a police officer from a Mossberg smooth-bore shotgun in an enclosed space from a distance of a few metres. The post-mortem examination revealed that death had been due to gunshot wounds in the chest which had caused heart and lung damage with subsequent massive internal haemorrhaging.

  19. 30 CFR 75.1101-16 - Dry powder chemical systems; sensing and fire-suppression devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... sensing device installed in such system. (b) Where sensors are operated from the same power source as the belt drive, each sensor shall be equipped with a standby power source which shall be capable of remaining operative for at least 4 hours after a power cutoff. (c) Sensor systems shall include a warning...

  20. 30 CFR 75.1101-16 - Dry powder chemical systems; sensing and fire-suppression devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... sensing device installed in such system. (b) Where sensors are operated from the same power source as the belt drive, each sensor shall be equipped with a standby power source which shall be capable of remaining operative for at least 4 hours after a power cutoff. (c) Sensor systems shall include a warning...

  1. 78 FR 1776 - Airworthiness Directives; International Aero Engines AG Turbofan Engines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-09

    ... Engines AG Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed... Aero Engines AG (IAE), V2525-D5 and V2528-D5 turbofan engines, with a certain number (No.) 4 bearing... proposed AD. Discussion We received a report of a fire warning on an IAE V2525 turbofan engine shortly...

  2. 30 CFR 75.1101-16 - Dry powder chemical systems; sensing and fire-suppression devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... sensing device installed in such system. (b) Where sensors are operated from the same power source as the belt drive, each sensor shall be equipped with a standby power source which shall be capable of remaining operative for at least 4 hours after a power cutoff. (c) Sensor systems shall include a warning...

  3. 30 CFR 75.1101-16 - Dry powder chemical systems; sensing and fire-suppression devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... sensing device installed in such system. (b) Where sensors are operated from the same power source as the belt drive, each sensor shall be equipped with a standby power source which shall be capable of remaining operative for at least 4 hours after a power cutoff. (c) Sensor systems shall include a warning...

  4. 30 CFR 75.1101-16 - Dry powder chemical systems; sensing and fire-suppression devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... sensing device installed in such system. (b) Where sensors are operated from the same power source as the belt drive, each sensor shall be equipped with a standby power source which shall be capable of remaining operative for at least 4 hours after a power cutoff. (c) Sensor systems shall include a warning...

  5. Light Armored Vehicle (LAV) Task and Media Analysis for the U.S. Marine Corps LAV-25.

    DTIC Science & Technology

    1983-08-26

    recommendations for literature to be ordered from DTIC. Finally, the Marketing Manager for International Laser Systems, Mr. Haro Schneider, was...in FIRE ( nline ).X 7.3.2 Wait five seconds. Press misfire reset warning indicator. x E-32 .. , HANDS-ON TRAINING TRAINING REQUIRED REQUIRED 7.3.3 Close

  6. Background information for Van Aken on testing of NESTT product

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reynolds, John G.

    2016-11-18

    Debris from explosives testing in a shot tank that contains 4 weight percent or less of explosive is shown to be non-reactive under the specified testing protocol in the Code of Federal Regulations. This debris can then be regarded as a non-hazardous waste on the basis of reactivity, when collected and packaged in a specified manner. If it is contaminated with radioactive components (e.g. depleted uranium), it can therefore be disposed of as radioactive waste or mixed waste, as appropriate (note that debris may contain other materials that render it hazardous, such as beryllium). We also discuss potential waste generationmore » issues in contained firing operations that are applicable to the planned new Contained Firing Facility (CFF).« less

  7. Sensor data monitoring and decision level fusion scheme for early fire detection

    NASA Astrophysics Data System (ADS)

    Rizogiannis, Constantinos; Thanos, Konstantinos Georgios; Astyakopoulos, Alkiviadis; Kyriazanos, Dimitris M.; Thomopoulos, Stelios C. A.

    2017-05-01

    The aim of this paper is to present the sensor monitoring and decision level fusion scheme for early fire detection which has been developed in the context of the AF3 Advanced Forest Fire Fighting European FP7 research project, adopted specifically in the OCULUS-Fire control and command system and tested during a firefighting field test in Greece with prescribed real fire, generating early-warning detection alerts and notifications. For this purpose and in order to improve the reliability of the fire detection system, a two-level fusion scheme is developed exploiting a variety of observation solutions from air e.g. UAV infrared cameras, ground e.g. meteorological and atmospheric sensors and ancillary sources e.g. public information channels, citizens smartphone applications and social media. In the first level, a change point detection technique is applied to detect changes in the mean value of each measured parameter by the ground sensors such as temperature, humidity and CO2 and then the Rate-of-Rise of each changed parameter is calculated. In the second level the fire event Basic Probability Assignment (BPA) function is determined for each ground sensor using Fuzzy-logic theory and then the corresponding mass values are combined in a decision level fusion process using Evidential Reasoning theory to estimate the final fire event probability.

  8. The National Ignition Facility: alignment from construction to shot operations

    NASA Astrophysics Data System (ADS)

    Burkhart, S. C.; Bliss, E.; Di Nicola, P.; Kalantar, D.; Lowe-Webb, R.; McCarville, T.; Nelson, D.; Salmon, T.; Schindler, T.; Villanueva, J.; Wilhelmsen, K.

    2010-08-01

    The National Ignition Facility in Livermore, California, completed it's commissioning milestone on March 10, 2009 when it fired all 192 beams at a combined energy of 1.1 MJ at 351nm. Subsequently, a target shot series from August through December of 2009 culminated in scale ignition target design experiments up to 1.2 MJ in the National Ignition Campaign. Preparations are underway through the first half of of 2010 leading to DT ignition and gain experiments in the fall of 2010 into 2011. The top level requirement for beam pointing to target of 50μm rms is the culmination of 15 years of engineering design of a stable facility, commissioning of precision alignment, and precise shot operations controls. Key design documents which guided this project were published in the mid 1990's, driving systems designs. Precision Survey methods were used throughout construction, commissioning and operations for precision placement. Rigorous commissioning processes were used to ensure and validate placement and alignment throughout commissioning and in present day operations. Accurate and rapid system alignment during operations is accomplished by an impressive controls system to align and validate alignment readiness, assuring machine safety and productive experiments.

  9. Study on the impact of exposure to noise in professional snipers.

    PubMed

    Barkokebas Junior, B; Lago, E; Vasconcelos, B; Oliveira, E

    2012-01-01

    Facing an increasing violence level and higher firepower in the hands of criminal organizations (especially those related to drug trafficking), the Military Police of Pernambuco has created, in 1989, the "1a Companhia Independente de Operações Especiais" (1st Independent Company of Special Operations), as a tactical last resort of the Police to be used on special, complex situations. The CIOE progressively makes use of Negotiation measures, of less-than-lethal maneuvers, of Precision Shots and Tactical Assaults. When all possibilities are drained, the Precision Shot will bring the crisis perpetrator down. This study had as an objective to assess the level of impact noise suffered by the elite snipers of the 1st CIOE-PE in their training. The working conditions of the snipers were evaluated through the use of a semi-structured questionnaire. Noise measuring was done on four (4) .308 IMBEL AGLC (with ammo from the same lot) rifles. Six (6) shots were fired off each gun, separated by a 30-second pause. In the end, it has been concluded that the noise level the 1st CIOE snipers are submitted to is considered to be normal by Brazilian legislation.

  10. A preliminary study into injuries due to non-perforating ballistic impacts into soft body armour over the spine.

    PubMed

    Jennings, Rosalind M; Malbon, Chris; Brock, Fiona; Harrisson, Stuart; Carr, Debra J

    2018-05-22

    The UK Home Office test method for ballistic protective police body armours considers anterior torso impacts to be the worst-case scenario and tests rear armour panels to the same standards as front panels. The aim of this paper was to examine the injuries from spinal behind armour blunt trauma (BABT) impacts. This study used a cadaveric 65 kg, female pig barrel and 9 mm Luger ammunition (9 × 19 mm, FMJ Nammo Lapur Oy) into HG1/A + KR1 soft armour panels over the spine. Injuries were inspected and sections removed for x-radiography and micro-CT assessment. All shots over the spine resulted in deep soft tissue injuries from pencilling of the armour and the shirt worn under the armour. The wounds had embedded fabric debris which would require surgery to remove resulting in increased recovery time over injuries usually seen in anterior torso BABT impacts, which are typically haematoma and fractured ribs. The shot with the deepest soft tissue wound (41 mm) also resulted in a fractured spinous process. Shots were also fired at the posterior and anterior rib area of the pig barrel, for comparison to the spine. Similar wounds were seen on the shots to the posterior rib area while shallower, smaller wounds were seen on the anterior and one anterior rib shot resulted in a single, un-displaced rib fracture. The anatomical differences between pigs and humans would most likely mean that injury to a human from these impacts would be more serious. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  11. Wounding potential of 4.4-mm (.173) caliber steel ball projectiles.

    PubMed

    Kamphausen, Thomas; Janßen, Katharina; Banaschak, Sibylle; Rothschild, Markus Alexander

    2018-03-06

    From time to time, severe or fatal injuries caused by small caliber air rifle projectiles are seen. In forensic sciences, the theoretical wounding potential of these weapons and projectiles is widely known. Usually, shots against the skull were reported and, in these cases, penetrating the eyes or thin bone layers of the temporal region. Amongst a huge number of different projectiles available for air guns, sub-caliber 4.4-mm (.173) caliber steel ball projectiles were used in an unusual suicide case. This case led to fundamental questions concerning wound ballistics. An 82-year-old man shot once against his right temporal region and twice into his mouth with a 4.5-mm (.177) caliber air rifle. Because of the exceptionally deep penetration of the base of the skull and the use of spherical-shaped sub-caliber air rifle projectiles, terminal ballistic features were analyzed and compared to results published in forensic literature. Test shots using the same weapon and similar projectiles were fired into ballistic gelatin to measure and calculate basic wound ballistic variables of cal. 4.4-mm (.173) steel balls. In comparison, further test shots with cal. 4.5-mm (.177) steel balls BB (ball bearing), flat-headed and pointed air rifle pellets ("diabolos") were carried out. The theoretical penetration depth in solid bone was calculated with 36.4 mm, and test shots in gelatin from hard contact produced an on-average wound track of 120 mm underlining the potential wounding effect. Furthermore, spherical projectiles could roll back and forth within the barrel, and an air cushion between projectile and breechblock can reduce muzzle velocity by more than half, explaining the retained missile in the temporal region.

  12. Fatalities caused by spherical bullets fired from blank cartridge guns in Istanbul, Turkey.

    PubMed

    Uzün, Ibrahim; Büyük, Yalçin; Erkol, Zerrin; Ağritmiş, Hasan; Kir, Ziya

    2009-09-01

    Blank cartridge guns are generally regarded as being harmless and are not considered to be firearms in the legal sense in most countries. To show the danger of these guns upon simple modifications, we report 59 fatalities resulting from these simply modified blank cartridge guns in Istanbul, Turkey. The great majority of the victims were males and the age of those ranged from 11 to 61 years. In 55.9% of these cases, homicide was the origin followed by suicide (39%). The right temporal region was detected to be the preferred region in suicidal shots by blank cartridge guns with a frequency of 56.5%. In trial shots, all these guns were detected to discharge steel or lead spherical objects, generally 4 or 5 mm in diameter, successfully. Our findings strongly suggest that these guns should also be considered as handguns in the legal sense.

  13. Generalized Lawson Criteria for Inertial Confinement Fusion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tipton, Robert E.

    2015-08-27

    The Lawson Criterion was proposed by John D. Lawson in 1955 as a general measure of the conditions necessary for a magnetic fusion device to reach thermonuclear ignition. Over the years, similar ignition criteria have been proposed which would be suitable for Inertial Confinement Fusion (ICF) designs. This paper will compare and contrast several ICF ignition criteria based on Lawson’s original ideas. Both analytical and numerical results will be presented which will demonstrate that although the various criteria differ in some details, they are closely related and perform similarly as ignition criteria. A simple approximation will also be presented whichmore » allows the inference of each ignition parameter directly from the measured data taken on most shots fired at the National Ignition Facility (NIF) with a minimum reliance on computer simulations. Evidence will be presented which indicates that the experimentally inferred ignition parameters on the best NIF shots are very close to the ignition threshold.« less

  14. REWSET: A prototype seismic and tsunami early warning system in Rhodes island, Greece

    NASA Astrophysics Data System (ADS)

    Papadopoulos, Gerasimos; Argyris, Ilias; Aggelou, Savvas; Karastathis, Vasilis

    2014-05-01

    Tsunami warning in near-field conditions is a critical issue in the Mediterranean Sea since the most important tsunami sources are situated within tsunami wave travel times starting from about five minutes. The project NEARTOWARN (2012-2013) supported by the EU-DG ECHO contributed substantially to the development of new tools for the near-field tsunami early warning in the Mediterranean. One of the main achievements is the development of a local warning system in the test-site of Rhodes island (Rhodes Early Warning System for Earthquakes and Tsunamis - REWSET). The system is composed by three main subsystems: (1) a network of eight seismic early warning devices installed in four different localities of the island, one in the civil protection, another in the Fire Brigade and another two in municipality buildings; (2) two radar-type (ultrasonic) tide-gauges installed in the eastern coastal zine of the island which was selected since research on the historical earthquake and tsunami activity has indicated that the most important, near-field tsunami sources are situated offshore to the east of Rhodes; (3) a crisis Geographic Management System (GMS), which is a web-based and GIS-based application incorporating a variety of thematic maps and other information types. The seismic early warning devices activate by strong (magnitude around 6 or more) earthquakes occurring at distances up to about 100 km from Rhodes, thus providing immediate mobilization of the civil protection. The tide-gauges transmit sea level data, while during the crisis the GMS supports decisions to be made by civil protection. In the near future it is planned the REWSET system to be integrated with national and international systems. REWSET is a prototype which certainly could be developed in other coastal areas of the Mediterranean and beyond.

  15. Test Operations Procedure (TOP) 4-2-013 Commodity Engineering Test Procedures, Recoilless Rifle Ammunition

    DTIC Science & Technology

    2009-09-22

    test officer). At a minimum, the CIL will be conducted at the operator level (often referred to as “field strip and clean”). More detailed...is checked before each shot is fired. Use a boresight (optical or laser ) as necessary to check alignment to the target aiming point if the barrel is...for this test should be representative of production. All components must be present, including projectile paint and markings, fuzes, any tool

  16. Signs of an Impending Hard Disk Crash

    ERIC Educational Resources Information Center

    Goldborough, Reid

    2004-01-01

    If you have worked with computers for any length of time, you have undoubtedly heard the warnings and the recommendations. Data stored on PCs can disappear in a nanosecond. You need to back up any crucial data you cannot risk losing. Ideally, you should store at least one set of crucial back-up data off-site in case of a fire, flood or other…

  17. No Moving Parts

    NASA Technical Reports Server (NTRS)

    1998-01-01

    Under a NASA SBIR (Small Business Innovative Research), Research International developed the solid state micromachined pump used for cooling electronics in space, circulation of heat transfer fluids on spacecraft, and monitoring fire and gas hazards aboard naval warships. Incorporating Lewis Research Center's pumping technology, commercial applications for this product include both detection of toxins and pollutants in coal mines, and early warning smoke detectors for industrial applications.

  18. Long-Lead Prediction of the 2015 Fire and Haze Episode in Indonesia

    NASA Astrophysics Data System (ADS)

    Shawki, Dilshad; Field, Robert D.; Tippett, Michael K.; Saharjo, Bambang Hero; Albar, Israr; Atmoko, Dwi; Voulgarakis, Apostolos

    2017-10-01

    We conducted a case study of National Centers for Environmental Prediction Climate Forecast System version 2 seasonal model forecast performance over Indonesia in predicting the dry conditions in 2015 that led to severe fire, in comparison to the non-El Niño dry season conditions of 2016. Forecasts of the Drought Code (DC) component of Indonesia's Fire Danger Rating System were examined across the entire equatorial Asia region and for the primary burning regions within it. Our results show that early warning lead times of high observed DC in September and October 2015 varied considerably for different regions. High DC over Southern Kalimantan and Southern New Guinea were predicted with 180 day lead times, whereas Southern Sumatra had lead times of up to only 60 days, which we attribute to the absence in the forecasts of an eastward decrease in Indian Ocean sea surface temperatures. This case study provides the starting point for longer-term evaluation of seasonal fire danger rating forecasts over Indonesia.

  19. A system study for the application of microcomputers to research flight test techniques

    NASA Technical Reports Server (NTRS)

    Smyth, R. K.

    1983-01-01

    The onboard simulator is a three degree of freedom aircraft behavior simulator which provides parameters used by the interception procedure. These parameters can be used for verifying closed loop performance before flight. The air to air intercept mode is a software package integrated in the simulation process that generates a target motion and performs a tracking procedure that predicts the most likely next target position, for a defined time step. This procedure also updates relative position parameters and gives adequate fire commands. A microcomputer based on an aircraft spin warning system periodically samples the assymetric thrust and yaw rate of an airplane and then issues voice synthesized warnings and /or suggests to the ilot how to respond to the situation.

  20. Monitoring of pipeline oil spill fire events using Geographical Information System and Remote Sensing

    NASA Astrophysics Data System (ADS)

    Ogungbuyi, M. G.; Eckardt, F. D.; Martinez, P.

    2016-12-01

    Nigeria, the largest producer of crude oil in Africa occupies sixth position in the world. Despite such huge oil revenue potentials, its pipeline network system is consistently susceptible to leaks causing oil spills. We investigate ground based spill events which are caused by operational error, equipment failure and most importantly by deliberate attacks along the major pipeline transport system. Sometimes, these spills are accompanied with fire explosion caused by accidental discharge, natural or illegal refineries in the creeds, etc. MODIS satellites fires data corresponding to the times and spill events (i.e. ground based data) of the Area of Interest (AOI) show significant correlation. The open source Quantum Geographical Information System (QGIS) was used to validate the dataset and the spatiotemporal analyses of the oil spill fires were expressed. We demonstrate that through QGIS and Google Earth (using the time sliders), we can identify and monitor oil spills when they are attended with fire events along the pipeline transport system accordingly. This is shown through the spatiotemporal images of the fires. Evidence of such fire cases resulting from bunt vegetation as different from industrial and domestic fire is also presented. Detecting oil spill fires in the study location may not require an enormous terabyte of image processing: we can however rely on a near-real-time (NRT) MODIS data that is readily available twice daily to detect oil spill fire as early warning signal for those hotspots areas where cases of oil seepage is significant in Nigeria.

  1. The Effect of Multiple Firings on the Shear Bond Strength of Porcelain to a New Millable Alloy and a Conventional Casting Alloy

    PubMed Central

    Farzin, Mitra; Giti, Rashin; Asalforush-Rezaiye, Amin

    2018-01-01

    This study compared the effect of multiple firings on the shear bond strength (SBS) of porcelain to the new millable alloy (Ceramill Sintron) and a conventional casting alloy (4-all). Thirty-six cylindrical cores (6.8 × 9 mm) were made of millable and castable alloy through CAD/CAM and casting techniques, respectively (n = 18). In the center of each bar, a 4 × 4 × 2-mm shot of porcelain was fused. Having divided each group into 3 subgroups based on the number of firing cycles (3, 5, 7), the specimens were fixed in a universal testing machine and underwent a shear force test (1.5 mm/min crosshead speed) until fractured. Then the SBS values (MPa) were calculated, and the failure patterns were microscopically characterized as adhesive, cohesive, or mixed. Two-way ANOVA statistical test revealed that the number of porcelain firings had no significant effect on the SBS of any of the metal groups (p = 0.1); however, it was statistically higher in the millable group than the castable group (p < 0.05). Moreover, detecting the mixed failure pattern in all the specimens implied that the multiple firings had no significant effect on the failure pattern. The multiple porcelain firings had no significant effect on the SBS of porcelain to neither the millable nor castable alloys. PMID:29565827

  2. Opposing resonses to ecological gradients structure amphibian and reptile communities across a temperate grassland-savanna-forest landscape

    USGS Publications Warehouse

    Grundel, Ralph; Beamer, David; Glowacki, Gary A.; Frohnapple, Krystal; Pavlovic, Noel B.

    2014-01-01

    Temperate savannas are threatened across the globe. If we prioritize savanna restoration, we should ask how savanna animal communities differ from communities in related open habitats and forests. We documented distribution of amphibian and reptile species across an open-savanna–forest gradient in the Midwest U.S. to determine how fire history and habitat structure affected herpetofaunal community composition. The transition from open habitats to forests was a transition from higher reptile abundance to higher amphibian abundance and the intermediate savanna landscape supported the most species overall. These differences warn against assuming that amphibian and reptile communities will have similar ecological responses to habitat structure. Richness and abundance also often responded in opposite directions to some habitat characteristics, such as cover of bare ground or litter. Herpetofaunal community species composition changed along a fire gradient from infrequent and recent fires to frequent but less recent fires. Nearby (200-m) wetland cover was relatively unimportant in predicting overall herpetofaunal community composition while fire history and fire-related canopy and ground cover were more important predictors of composition, diversity, and abundance. Increased developed cover was negatively related to richness and abundance. This indicates the importance of fire history and fire related landscape characteristics, and the negative effects of development, in shaping the upland herpetofaunal community along the native grassland–forest continuum.

  3. Aircraft Survivability: Space Survivability - Time to Get Serious, Summer 2008

    DTIC Science & Technology

    2008-01-01

    modified to allow a capabil- ity to launch MANPADS with live warheads. Thus, METS was born. METS is a single - stage cold gas gun that uses compressed...30 feet from the target (see Figure 3). API projectiles or frag- ments fired from the gun passed through a sabot catcher (a thick metal plate with a...Body (T=2040K) Fit Water (T=2010K) Detectors Sabot catcher Shot line Gun Test Fixture Target Panel Figure 2 An Instantaneous Temperature Measurement in

  4. Aircraft Evaluation Using Stochastic Duels

    DTIC Science & Technology

    2017-09-01

    One of the more recent uses of Lanchester equations for modeling air-to-air combat was proposed by Gilbert (2011). His work studies the strategic...for the number of missiles fired on each side. C. PHASE 2—DOGFIGHT If neither aircraft is shot down in Phase 1, the duel will transit into Phase 2...become the Pursuer of B at the of the turn. On the other hand, in the case of a nose-to-tail turn, the impacts of the turn radius and turn rate are

  5. Agent-Based Simulation to Support the Effectiveness, Procurement, and Employment of Non-Lethal Weapon Systems

    DTIC Science & Technology

    2017-06-01

    cases have the most significant impact on reducing the number of lethal shots fired in the simulation. Table 10 shows the reduction in the average...Figure ES-2 was developed to show the results of the focused study on maximum effective range. After analyzing the results of the 1,700 simulated...toward other agents based on whose side they are on at that time. This attribute is critical to this study as the sidedness of the local population is

  6. Self-Defense by Any Other Name is Still Self-Defense

    DTIC Science & Technology

    2003-04-01

    Unlimited D D15Th3WON STAT13ENT L YNANNOUNIPV 03 JUSMIICATION BY DISTIBUTON/T AVAILABILIT CODES DIST1ZDtmN AVAILABILI AQM SPECI~ALH DATE ACCMSIONED...homeport? When the invasion force enters another state’s sovereign waters ? Is it as simplistic as which side fired the first shot? 34 These rhetorical...States’ sovereignty in her territorial waters and even led to the occasional killing of Whereas armed vessels sailing under authority or pretence of

  7. On the Behaviour of Porcine Adipose and Skeletal Muscle Tissues under Shock Compression

    DTIC Science & Technology

    2012-09-01

    74 (breech pressure) shots. Secondly, a smaller vacuum pump evacuates the air within both the barrel of the gun and a sealed section mounted at the end...pressure. To fire the gun this cavity was rapidly evacuated, allowing first the disk adjacent to the breech and then that adjacent to the barrel to...of the gun , i.e. the barrel section. Such action allowed for a much stronger vacuum to be created than within the rearward expansion chamber and

  8. Characterization and Discrimination of Large Caliber Gun Blast and Flash Signatures

    DTIC Science & Technology

    2011-10-01

    from one end of a barrel (the muzzle) by the application of force at the other end. In conventional guns , force is provided by the combustion of a...projectile begins to accelerate down the barrel ; this is known as shot start. As the projectile traverses the gun barrel and additional volume becomes...flash that is used today resulted from this program’s report. Visible and ultraviolet (UV) spectra of 20 mm and .50 caliber machine gun firings were

  9. Project CHECO Southeast Asia Report. USAF Tactics Against Air & Ground Defenses in SEA, November 1968 - May 1970

    DTIC Science & Technology

    1970-09-25

    EB-66 Orbits for Drone Flight .......................... 50 16. ( EB-66 Orbits in Support of B-52 Mission ................ 50I 3 ix I~WI ’CNON.11...outmaneuver it. During the period of this report, while SAMs were fired at several USAF aircraft and shot down several drones , the USAF lost no manned...Oblique camaras had beendesigned to allow photography from a safe distance, but the heavy tree cover in Laos usually required vertical photography for

  10. Environmental Assessment: Addressing Construction Projects at Niagara Falls Air Reserve Station, New York

    DTIC Science & Technology

    2011-07-01

    Aeronautical Research Center missile site (Site 5), JP-4 tank truck spill (Site 7) at the eastern end of Taxiway A, Building 202 Drum Storage Yard (Site...BNOISE2. BNOISE2 was developed by the . U.S. Army Construction Engineering Research Laboratory for the Operational Noise to assess large arms weapons...was estimated using the OneShot component of BNOISE2. Per AR 200-1, if there are multiple weapon types fired from one location, the single-event

  11. Fire-probability maps for the Brazilian Amazonia

    NASA Astrophysics Data System (ADS)

    Cardoso, M.; Nobre, C.; Obregon, G.; Sampaio, G.

    2009-04-01

    Most fires in Amazonia result from the combination between climate and land-use factors. They occur mainly in the dry season and are used as an inexpensive tool for land clearing and management. However, their unintended consequences are of important concern. Fire emissions are the most important sources of greenhouse gases and aerosols in the region, accidental fires are a major threat to protected areas, and frequent fires may lead to permanent conversion of forest areas into savannas. Fire-activity models have thus become important tools for environmental analyses in Amazonia. They are used, for example, in warning systems for monitoring the risk of burnings in protected areas, to improve the description of biogeochemical cycles and vegetation composition in ecosystem models, and to help estimate the long-term potential for savannas in biome models. Previous modeling studies for the whole region were produced in units of satellite fire pixels, which complicate their direct use for environmental applications. By reinterpreting remote-sensing based data using a statistical approach, we were able to calibrate models for the whole region in units of probability, or chance of fires to occur. The application of these models for years 2005 and 2006 provided maps of fire potential at 3-month and 0.25-deg resolution as a function of precipitation and distance from main roads. In both years, the performance of the resulting maps was better for the period July-September. During these months, most of satellite-based fire observations were located in areas with relatively high chance of fire, as determined by the modeled probability maps. In addition to reproduce reasonably well the areas presenting maximum fire activity as detected by remote sensing, the new results in units of probability are easier to apply than previous estimates from fire-pixel models.

  12. Fire-probability maps for the Brazilian Amazonia

    NASA Astrophysics Data System (ADS)

    Cardoso, Manoel; Sampaio, Gilvan; Obregon, Guillermo; Nobre, Carlos

    2010-05-01

    Most fires in Amazonia result from the combination between climate and land-use factors. They occur mainly in the dry season and are used as an inexpensive tool for land clearing and management. However, their unintended consequences are of important concern. Fire emissions are the most important sources of greenhouse gases and aerosols in the region, accidental fires are a major threat to protected areas, and frequent fires may lead to permanent conversion of forest areas into savannas. Fire-activity models have thus become important tools for environmental analyses in Amazonia. They are used, for example, in warning systems for monitoring the risk of burnings in protected areas, to improve the description of biogeochemical cycles and vegetation composition in ecosystem models, and to help estimate the long-term potential for savannas in biome models. Previous modeling studies for the whole region were produced in units of satellite fire pixels, which complicate their direct use for environmental applications. By reinterpreting remote-sensing based data using a statistical approach, we were able to calibrate models for the whole region in units of probability, or chance of fires to occur. The application of these models for years 2005 and 2006 provided maps of fire potential at 3-month and 0.25-deg resolution as a function of precipitation and distance from main roads. In both years, the performance of the resulting maps was better for the period July-September. During these months, most of satellite-based fire observations were located in areas with relatively high chance of fire, as determined by the modeled probability maps. In addition to reproduce reasonably well the areas presenting maximum fire activity as detected by remote sensing, the new results in units of probability are easier to apply than previous estimates from fire-pixel models.

  13. Fire-induced pine woodland to shrubland transitions in Southern Europe may promote shifts in soil fertility.

    PubMed

    Mayor, A G; Valdecantos, A; Vallejo, V R; Keizer, J J; Bloem, J; Baeza, J; González-Pelayo, O; Machado, A I; de Ruiter, P C

    2016-12-15

    Since the mid of the last century, fire recurrence has increased in the Iberian Peninsula and in the overall Mediterranean basin due to changes in land use and climate. The warmer and drier climate projected for this region will further increase the risk of wildfire occurrence and recurrence. Although the impact of wildfires on soil nutrient content in this region has been extensively studied, still few works have assessed this impact on the basis of fire recurrence. This study assesses the changes in soil organic C and nutrient status of mineral soils in two Southern European areas, Várzea (Northern Portugal) and Valencia (Eastern Spain), affected by different levels of fire recurrence and where short fire intervals have promoted a transition from pine woodlands to shrublands. At the short-term (<1year), the amount of soil organic matter was higher in burned than in unburned soils while its quality (represented as labile to total organic matter) was actually lower. In any case, total and labile soil organic matter showed decreasing trends with increasing fire recurrence (one to four fires). At the long-term (>5years), a decline in overall soil fertility with fire recurrence was also observed, with a drop between pine woodlands (one fire) and shrublands (two and three fires), particularly in the soil microsites between shrubs. Our results suggest that the current trend of increasing fire recurrence in Southern Europe may result in losses or alterations of soil organic matter, particularly when fire promotes a transition from pine woodland to shrubland. The results also point to labile organic matter fractions in the intershrub spaces as potential early warning indicators for shifts in soil fertility in response to fire recurrence. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. 30 CFR 75.1103-4 - Automatic fire sensor and warning device systems; installation; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up. If the belt drive, tailpiece, and/or take-up for a single transfer point are installed together in the same air course, and the... downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up; (ii) Not more than...

  15. 30 CFR 75.1103-4 - Automatic fire sensor and warning device systems; installation; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up. If the belt drive, tailpiece, and/or take-up for a single transfer point are installed together in the same air course, and the... downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up; (ii) Not more than...

  16. 30 CFR 75.1103-4 - Automatic fire sensor and warning device systems; installation; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up. If the belt drive, tailpiece, and/or take-up for a single transfer point are installed together in the same air course, and the... downwind of each belt drive unit, each tailpiece transfer point, and each belt take-up; (ii) Not more than...

  17. Analysis of Local Planning Interviews.

    DTIC Science & Technology

    1984-04-01

    Suite 121, P.O. Box 2487 Project No. 4813-D Kirkland, WA 98033 II. CONTROLLING OFFICE NAME AND ADDRESS 12. REPORT DATE Federal Emergency Management...Agency April 1984 Washington, D.C. 20472 13. NUMBER OF PAGES31 14. MONITORING AGENCY NAME & ADDRESS(If different from Controlling Office) IS. SECURITY...and Control and the basic emergency functions (Warning, RADEF, Law Enforcement, Fire, Communications, Public Information, Health, Medical, Evacuation

  18. Data report for onshore-offshore wide-angle seismic recordings in the Bering-Chukchi Sea, Western Alaska and eastern Siberia

    USGS Publications Warehouse

    Brocher, Thomas M.; Allen, Richard M.; Stone, David B.; Wolf, Lorraine W.; Galloway, Brian K.

    1995-01-01

    This report presents fourteen deep-crustal wide-angle seismic reflection and refraction profiles recorded onland in western Alaska and eastern Siberia from marine air gun sources in the Bering-Chukchi Seas. During a 20-day period in August, 1994, the R/V Ewing acquired two long (a total of 3754 km) deep-crustal seismic-reflection profiles on the continental shelf of the Bering and Chukchi Seas, in a collaborative project between Stanford University and the United States Geological Survey (USGS). The Ewing's 137.7 liter (8355 cu. in.) air gun array was the source for both the multichannel reflection and the wide-angle seismic data. The Ewing, operated by the Lamont-Doherty Earth Observatory, steamed northward from Nunivak Island to Barrow, and returned, firing the air gun array at intervals of either 50 m or 75 m. About 37,700 air gun shots were fired along the northward directed Lines 1 and 2, and more than 40,000 air gun shots were fired along the southward directed Line 3. The USGS and the University of Alaska, Fairbanks (UAF), deployed an array of twelve 3-component REFTEK and PDAS recorders in western Alaska and eastern Siberia which continuously recorded the air gun signals fired during the northward bound Lines 1 and 2. Seven of these recorders also continuously recorded the southward bound Line 3. These wide-angle seismic data were acquired to: (1) image reflectors in the upper to lower crust, (2) determine crustal and upper mantle refraction velocities, and (3) provide important constraints on the geometry of the Moho along the seismic lines. In this report, we describe the land recording of wide-angle data conducted by the USGS and the UAF, describe in detail how the wide-angle REFTEK and PDAS data were reduced to common receiver gather seismic sections, and illustrate the wide-angle seismic data obtained by the REFTEKs and PDAS's. Air gun signals were observed to ranges in excess of 400 km, and crustal and upper /mantle refractions indicate substantial variation in the crustal thickness along the transect.

  19. Advancement and results in hostile fire indication using potassium line missile warning sensors

    NASA Astrophysics Data System (ADS)

    Montgomery, Joel; Montgomery, Marjorie; Hardie, Russell

    2014-06-01

    M&M Aviation has been developing and conducting Hostile Fire Indication (HFI) tests using potassium line emission sensors for the Air Force Visible Missile Warning System (VMWS) to advance both algorithm and sensor technologies for UAV and other airborne systems for self protection and intelligence purposes. Work began in 2008 as an outgrowth of detecting and classifying false alarm sources for the VMWS using the same K-line spectral discrimination region but soon became a focus of research due to the high interest in both machine-gun fire and sniper geo-location via airborne systems. Several initial tests were accomplished in 2009 using small and medium caliber weapons including rifles. Based on these results, the Air Force Research Laboratory (AFRL) funded the Falcon Sentinel program in 2010 to provide for additional development of both the sensor concept, algorithm suite changes and verification of basic phenomenology including variance based on ammunition type for given weapons platform. Results from testing over the past 3 years have showed that the system would be able to detect and declare a sniper rifle at upwards of 3km, medium machine gun at 5km, and explosive events like hand-grenades at greater than 5km. This paper will outline the development of the sensor systems, algorithms used for detection and classification, and test results from VMWS prototypes as well as outline algorithms used for the VMWS. The Falcon Sentinel Program will be outlined and results shown. Finally, the paper will show the future work for ATD and transition efforts after the Falcon Sentinel program completed.

  20. Ballistic fractures: indirect fracture to bone.

    PubMed

    Dougherty, Paul J; Sherman, Don; Dau, Nathan; Bir, Cynthia

    2011-11-01

    Two mechanisms of injury, the temporary cavity and the sonic wave, have been proposed to produce indirect fractures as a projectile passes nearby in tissue. The purpose of this study is to evaluate the temporal relationship of pressure waves using strain gauge technology and high-speed video to elucidate whether the sonic wave, the temporary cavity, or both are responsible for the formation of indirect fractures. Twenty-eight fresh frozen cadaveric diaphyseal tibia (2) and femurs (26) were implanted into ordnance gelatin blocks. Shots were fired using 9- and 5.56-mm bullets traversing through the gelatin only, passing close to the edge of the bone, but not touching, to produce an indirect fracture. High-speed video of the impact event was collected at 20,000 frames/s. Acquisition of the strain data were synchronized with the video at 20,000 Hz. The exact time of fracture was determined by analyzing and comparing the strain gauge output and video. Twenty-eight shots were fired, 2 with 9-mm bullets and 26 with 5.56-mm bullets. Eight indirect fractures that occurred were of a simple (oblique or wedge) pattern. Comparison of the average distance of the projectile from the bone was 9.68 mm (range, 3-20 mm) for fractured specimens and 15.15 mm (range, 7-28 mm) for nonfractured specimens (Student's t test, p = 0.036). In this study, indirect fractures were produced after passage of the projectile. Thus, the temporary cavity, not the sonic wave, was responsible for the indirect fractures.

  1. Robotic Vehicle Communications Interoperability

    DTIC Science & Technology

    1988-08-01

    starter (cold start) X X Fire suppression X Fording control X Fuel control X Fuel tank selector X Garage toggle X Gear selector X X X X Hazard warning...optic Sensors Sensor switch Video Radar IR Thermal imaging system Image intensifier Laser ranger Video camera selector Forward Stereo Rear Sensor control...optic sensors Sensor switch Video Radar IR Thermal imaging system Image intensifier Laser ranger Video camera selector Forward Stereo Rear Sensor

  2. Fabrication and evaluation of polymeric early-warning fire-alarm devices. [combustion products

    NASA Technical Reports Server (NTRS)

    Senturia, S. D.

    1975-01-01

    The electrical resistivities were investigated of some polymers known to be enhanced by the presence of certain gases. This was done to make a device capable of providing early warning to fire through its response with the gases produced in the early phases of combustion. Eight polymers were investigated: poly(phenyl acetylene), poly(p-aminophenyl acetylene), poly(p-nitrophenyl acetylene), poly(p-formamidophenyl acetylene), poly(ethynyl ferrocene), poly(ethynyl carborane), poly(ethynyl pyridine), and the polymer made from 1,2,3,6 tetramethyl pyridazine. A total of 40 usable thin-film sandwich devices and a total of 70 usable interdigitated-electrode lock-and-key devices were fabricated. The sandwich devices were used for measurements of contact linearity, polymer conductivity, and polymer dielectric constant. The lock-and-key devices were used to determine the response of the polymers to a spectrum of gases that included ammonia, carbon nonoxide, carbon dioxide, sulfur dioxide, ethylene, acrolein, water vapor, and normal laboratory air. Strongest responses were to water vapor, ammonia, and acrolein, and depending on the polymer, weaker responses to carbon dioxide, sulfur dioxide, and carbon monoxide were observed. A quantitative theory of device operation, capable of accounting for observed device leakage current and sensitivity, was developed. A prototype detection/alarm system was designed and built for use in demonstrating sensor performance.

  3. Results of field testing with the FightSight infrared-based projectile tracking and weapon-fire characterization technology

    NASA Astrophysics Data System (ADS)

    Snarski, Steve; Menozzi, Alberico; Sherrill, Todd; Volpe, Chris; Wille, Mark

    2010-04-01

    This paper describes experimental results from recent live-fire data collects that demonstrate the capability of a prototype system for projectile detection and tracking. This system, which is being developed at Applied Research Associates, Inc., under the FightSight program, consists of a high-speed thermal camera and sophisticated image processing algorithms to detect and track projectiles. The FightSight operational vision is automated situational intelligence to detect, track, and graphically map large-scale firefights and individual shooting events onto command and control (C2) systems in real time (shot location and direction, weapon ID, movements and trends). Gaining information on enemy-fire trajectories allows educated inferences on the enemy's intent, disposition, and strength. Our prototype projectile detection and tracking system has been tested at the Joint Readiness Training Center (Ft Polk, LA) during live-fire convoy and mortar registration exercises, in the summer of 2009. It was also tested during staged military-operations- on-urban-terrain (MOUT) firefight events at Aberdeen Test Center (Aberdeen, MD) under the Hostile Fire Defeat Army Technology Objective midterm experiment, also in the summer of 2009, where we introduced fusion with acoustic and EO sensors to provide 3D localization and near-real time display of firing events. Results are presented in this paper that demonstrate effective and accurate detection and localization of weapon fire (5.56mm, 7.62mm, .50cal, 81/120mm mortars, 40mm) in diverse and challenging environments (dust, heat, day and night, rain, arid open terrain, urban clutter). FightSight's operational capabilities demonstrated under these live-fire data collects can support closecombat scenarios. As development continues, FightSight will be able to feed C2 systems with a symbolic map of enemy actions.

  4. Classification Model for Forest Fire Hotspot Occurrences Prediction Using ANFIS Algorithm

    NASA Astrophysics Data System (ADS)

    Wijayanto, A. K.; Sani, O.; Kartika, N. D.; Herdiyeni, Y.

    2017-01-01

    This study proposed the application of data mining technique namely Adaptive Neuro-Fuzzy inference system (ANFIS) on forest fires hotspot data to develop classification models for hotspots occurrence in Central Kalimantan. Hotspot is a point that is indicated as the location of fires. In this study, hotspot distribution is categorized as true alarm and false alarm. ANFIS is a soft computing method in which a given inputoutput data set is expressed in a fuzzy inference system (FIS). The FIS implements a nonlinear mapping from its input space to the output space. The method of this study classified hotspots as target objects by correlating spatial attributes data using three folds in ANFIS algorithm to obtain the best model. The best result obtained from the 3rd fold provided low error for training (error = 0.0093676) and also low error testing result (error = 0.0093676). Attribute of distance to road is the most determining factor that influences the probability of true and false alarm where the level of human activities in this attribute is higher. This classification model can be used to develop early warning system of forest fire.

  5. [Expert reconstruction of the true circumstances of the shooting of the Emperor Nikolai II, members of his family, and those who accompanied them into exile at Ekaterinburg].

    PubMed

    Kovalev, A V; Kolkutin, V V

    2011-01-01

    Analysis of the materials of the criminal case, historical, archive, and forensic medical documents permitted for the first time to reconstruct the circumstances of the shooting of Emperor Nikolai II, members of the royal family, and those who chose to accompany them into exile in the house of the engineer N.N. Ipatiev, Ekaterinburg, on the night of 16-17th July (Grigorian calendar) 1918. The results of the study allowed the true picture of the assassination to be reconstructed including the mutual positions of the victims and the executors in the semi-basement room No 2, the total number of participants, the number and direction of shots, the types of the weapons used, and the sequence of actions of each person involved in the event. It was shown, that in the beginning most shots had been fired at the emperor and tsarevich Alexei.

  6. 1986 Great Lakes Seismic refraction survey (GLIMPCE): Line A - refraction mode

    USGS Publications Warehouse

    Morel-a-l'Huissier, Patrick; Karl, John H.; Tréhu, Anne M.; Hajnal, Zoltan; Mereu, Robert F.; Meyer, Robert P.; Sexton, John L.; Ervin, C. Patrick; Green, Alan G.; Hutchinson, Deborah

    1990-01-01

    In the fall of 1986, the Geological Survey of Canada (GSC), the United States Geological Survey (USGS), two Canadian universities -- University of Western Ontario and University of Saskatchewan, and four American universities -- Northern Illinois University, Southern Illinois University, University of Wisconsin-Madison and University of Wisconsin-Oshkosh participated in a major deep seismic experiment in Lake Superior under the GLIMPCE (Great Lakes International Multidisciplinary Program on Crustal Evolution) umbrella. This Open-File Report presents the seismic sections for line A, which was shot specifically for refraction recording. The main target for study by this line was the Mid-Continent Rift System. All recording stations, 31 in total (26 land stations and 5 OBSs), recorded energy from shots fired every two minutes (333 m spacing) by a tuned airgun array towed by a contracted ship along line A in Lake Superior. These data are the densest such data ever recorded in the continental North America over such distances. It is also unique since coincident seismic reflection and refraction are available.

  7. Sonoran Desert: Fragile Land of Extremes

    USGS Publications Warehouse

    Produced and Directed by Wessells, Stephen

    2003-01-01

    'Sonoran Desert: Fragile Land of Extremes' shows how biologists with the U.S. Geological Survey work with other scientists in an effort to better understand native plants and animals such as desert tortoises, saguaro cacti, and Gila monsters. Much of the program was shot in and around Saguaro National Park near Tucson, Arizona. Genetic detective work, using DNA, focuses on understanding the lives of tortoises. Studies of saguaros over many decades clarify how these amazing plants reproduce and thrive in the desert. Threats from fire, diseases in tortoises, and a growing human population motivate the scientists. Their work to identify how these organisms live and survive is a crucial step for the sound management of biological resources on public lands. This 28-minute program, USGS Open-File Report 03-305, was shot entirely in high definition video and produced by the USGS Western Ecological Research Center and Southwest Biological Science Center; produced and directed by Stephen Wessells, Western Region Office of Communications.

  8. Civil Protection Practitioners' Response to Introducing Nowcasting in Weather Warnings

    NASA Astrophysics Data System (ADS)

    Ulbrich, Thorsten

    2014-05-01

    The HErZ project WEXICOM (Improving the process of weather warnings and extreme weather information in the chain from the meteorological forecasts to their communication for the Berlin conurbation) assesses the communication and use of weather warnings. In cooperation with DWD we conducted two online surveys with German relief forces before and after a nowcasting application was introduced into the weather warning platform FEWIS. The aim is to investigate how relief workers make use of the additional information. DWD supports German civil protection by providing the warning platform FeWIS (Fire brigade Weather Information System) for registered relief workers. The platform provides information on meteorological hazards needed to take precautions and to support rescue actions. In June 2013 DWD added nowcasted estimates of storm attributes including warning cones based on a 1x1 km grid. The tool named "GewitterMonitor" is based on NowcastMIX and uses short-term weather models and observations to derive warnings with high precision on intensity, location and timing of thunder storm cells for the following two hours. A first survey provided prior to the addition of nowcasted information investigates how users benefit from FeWIS and how they perceive its functionality and reliability. Following the introduction users gain experience applying the nowcasting tool in the thunderstorm season 2013. In Winter 2013/2014 we conducted another online survey. The post-survey comprises questions on the use of the GewitterMonitor and on how the tool supports relief forces in responding to meteorological risks. The post survey also repeats questions on the perception of functionality and function of FeWIS and poses questions derived from the previous survey. This second survey collects practitioners feedback on GewitterMonitor and allows to detect changes in how users perceive the performance of FeWIS after the addition by relating responses to the prior survey.

  9. Advanced multispectral dynamic thermography as a new tool for inspection of gas-fired furnaces

    NASA Astrophysics Data System (ADS)

    Pregowski, Piotr; Goleniewski, Grzegorz; Komosa, Wojciech; Korytkowski, Waldemar

    2004-04-01

    The main special feature of elaborated method is that the dynamic IR thermography (DIRT) bases on forming of single image consisting of pixels of chosen minimum (IMAX) or maximum (IMAX) value, noted during adequately long sequence of thermograms with total independence to the moment of its (image's) capture. In this way, additive or suppressed interferences of fluctuating character become bypassed. Due to this method thereafter elaborated in classic way such "artificial thermogram" offers the quality impossible to achieve with a classic "one shot" method. Although preliminary, results obtained clearly show great potential of the method. and confirmed the validity in decreasing errors caused by fluctuating disturbances. In the case of process furnaces of gas-fired type and especially of coal-fired, application of presented solutions should result in significant increasing the reliability of IR thermography application. By use of properly chosen optical filters and algorithm, elaborated method offers a new potential attractive to test temperature problems other than in tubes , as for example symmetry and efficiency of the furnace heaters.

  10. Protection against fire in the mountainous forests of Greece case study: forest complex of W. Nestos

    NASA Astrophysics Data System (ADS)

    Drosos, Vasileios C.; Giannoulas, Vasileios J.; Stergiadou, Anastasia; Karagiannis, Evaggelos; Doukas, Aristotelis-Kosmas G.

    2014-08-01

    Forest fires are an ancient phenomenon. Appear, however, with devastating frequency and intensity over the last 30 years. In our country, the climatic conditions in combination with the intense relief, favor their rapid spread. Considering the fact that environmental conditions provided for decades even worse (increased temperature, drought and vegetation), then the problem of forest fires in our country, is expected to become more intense. The work focuses on the optimization model of the opening up of the forest mountain areas taking into account the prevention and suppression of forest fires. Research area is the mountain forest complex of W. Nestos of Drama Prefecture. The percentage of forest protection area is examined under the light whether the total hose length corresponds to the actual operational capacity to reach a fire source. For this reason are decided to present a three case study concerning area of the forest being protected by fire extinguishing vehicles. The first one corresponds to a fire suppression bandwidth (buffer zone) with a capacity radius of 150m uphill and 250m downhill from the origin point where the fire extinguishing vehicle stands. The second one corresponds to a fire suppression capacity of 200m uphill and 400m downhill and the third one corresponds to a fire suppression capacity of 300m uphill and 500m downhill. The most important forest technical infrastructures to prevent fire are roads network (opening up) for fire protection and buffer zones. Patrols of small and agile 4 × 4 appropriately equipped (pipe length of 500 meters and putting pressure on uphill to 300 meters) for the first attack of the fire in the summer months coupled with early warning of fire observatories adequately cover the forest protection of W. Nestos complex. But spatial distribution needed improvements to a road density of the optimum economic Dec, both forest protection and for better management (skidding) of woody capital.

  11. Soviet Union, Military Affairs. Data, Diagrams of Ground Forces Weaponry.

    DTIC Science & Technology

    1987-07-16

    roadless areas at speeds of up to 10 -20 kilometers per hour. And now, something about the gun’s design. I shall name its main parts and indi- cate their...27.4 ■ kilograms. At the prescribed rate of fire, which is six rounds per minute, the loader must "move" 10 poods of metal every 60 seconds. This...It is 600 rounds per minute for the AKM. When the tregger is pressed the shots occur one after another, every 0.1 second. This means that 10

  12. International Relations, New Technology, and Adaptation of the Military Innovation: Focusing on the Case of the Aircraft Carrier Innovation of the Imperial Japanese Navy During the Interwar Period

    DTIC Science & Technology

    2017-12-01

    AP), a kinetic energy shot. On the other hand, there were many unexploded bombs in Russian fires.45 Consequently, a large ship equipped with large...hits of 240kg bombs . Despite these efforts, after the Washington Naval Treaty, the IJN focused on auxiliary warships such as submarines and cruisers...late 1920s, the IJN began to strengthen its aviation capabilities by consolidating aviation-related organizations and strengthening bombing training.108

  13. Redesigning Strategy for Irregular War: Improving Strategic Design for Planners and Policymakers to Help Defeat Groups Like the Islamic State

    DTIC Science & Technology

    2016-12-01

    effective when they cannot see a clear linkage between their actions and a strategic purpose.22 In the ideal case , a military strategy designed to...in attendance. 27 Davis, 2015. 11 operational levels of war…”28 This problem is compounded in irregular wars like the one designed to...a “clear-division-of-labor” approach to war, in which the military’s role ends the when the last shot is fired on the field of battle. But Rose

  14. Defeating the Active Shooter: Applying Facility Upgrades in Order to Mitigate the Effects of Active Shooters in High Occupancy Facilities

    DTIC Science & Technology

    2012-06-01

    Virginia Tech, 90. 51 exterior doors, he roamed the halls of the second floor peering into classrooms. Without saying a word, Cho entered the...carried out his actions in complete silence without saying a word. He gave no indication of rationale or motive during the entire incident that lasted...without saying a word, proceeded to open fire on the classroom. Goddard, the student who had called 9-1-1, was among the first to be shot. As he fell

  15. Prediction of spatially explicit rainfall intensity-duration thresholds for post-fire debris-flow generation in the western United States

    NASA Astrophysics Data System (ADS)

    Staley, Dennis; Negri, Jacquelyn; Kean, Jason

    2016-04-01

    Population expansion into fire-prone steeplands has resulted in an increase in post-fire debris-flow risk in the western United States. Logistic regression methods for determining debris-flow likelihood and the calculation of empirical rainfall intensity-duration thresholds for debris-flow initiation represent two common approaches for characterizing hazard and reducing risk. Logistic regression models are currently being used to rapidly assess debris-flow hazard in response to design storms of known intensities (e.g. a 10-year recurrence interval rainstorm). Empirical rainfall intensity-duration thresholds comprise a major component of the United States Geological Survey (USGS) and the National Weather Service (NWS) debris-flow early warning system at a regional scale in southern California. However, these two modeling approaches remain independent, with each approach having limitations that do not allow for synergistic local-scale (e.g. drainage-basin scale) characterization of debris-flow hazard during intense rainfall. The current logistic regression equations consider rainfall a unique independent variable, which prevents the direct calculation of the relation between rainfall intensity and debris-flow likelihood. Regional (e.g. mountain range or physiographic province scale) rainfall intensity-duration thresholds fail to provide insight into the basin-scale variability of post-fire debris-flow hazard and require an extensive database of historical debris-flow occurrence and rainfall characteristics. Here, we present a new approach that combines traditional logistic regression and intensity-duration threshold methodologies. This method allows for local characterization of both the likelihood that a debris-flow will occur at a given rainfall intensity, the direct calculation of the rainfall rates that will result in a given likelihood, and the ability to calculate spatially explicit rainfall intensity-duration thresholds for debris-flow generation in recently burned areas. Our approach synthesizes the two methods by incorporating measured rainfall intensity into each model variable (based on measures of topographic steepness, burn severity and surface properties) within the logistic regression equation. This approach provides a more realistic representation of the relation between rainfall intensity and debris-flow likelihood, as likelihood values asymptotically approach zero when rainfall intensity approaches 0 mm/h, and increase with more intense rainfall. Model performance was evaluated by comparing predictions to several existing regional thresholds. The model, based upon training data collected in southern California, USA, has proven to accurately predict rainfall intensity-duration thresholds for other areas in the western United States not included in the original training dataset. In addition, the improved logistic regression model shows promise for emergency planning purposes and real-time, site-specific early warning. With further validation, this model may permit the prediction of spatially-explicit intensity-duration thresholds for debris-flow generation in areas where empirically derived regional thresholds do not exist. This improvement would permit the expansion of the early-warning system into other regions susceptible to post-fire debris flow.

  16. Earthquake Early Warning Beta Users: Java, Modeling, and Mobile Apps

    NASA Astrophysics Data System (ADS)

    Strauss, J. A.; Vinci, M.; Steele, W. P.; Allen, R. M.; Hellweg, M.

    2014-12-01

    Earthquake Early Warning (EEW) is a system that can provide a few to tens of seconds warning prior to ground shaking at a user's location. The goal and purpose of such a system is to reduce, or minimize, the damage, costs, and casualties resulting from an earthquake. A demonstration earthquake early warning system (ShakeAlert) is undergoing testing in the United States by the UC Berkeley Seismological Laboratory, Caltech, ETH Zurich, University of Washington, the USGS, and beta users in California and the Pacific Northwest. The beta users receive earthquake information very rapidly in real-time and are providing feedback on their experiences of performance and potential uses within their organization. Beta user interactions allow the ShakeAlert team to discern: which alert delivery options are most effective, what changes would make the UserDisplay more useful in a pre-disaster situation, and most importantly, what actions users plan to take for various scenarios. Actions could include: personal safety approaches, such as drop cover, and hold on; automated processes and procedures, such as opening elevator or fire stations doors; or situational awareness. Users are beginning to determine which policy and technological changes may need to be enacted, and funding requirements to implement their automated controls. The use of models and mobile apps are beginning to augment the basic Java desktop applet. Modeling allows beta users to test their early warning responses against various scenarios without having to wait for a real event. Mobile apps are also changing the possible response landscape, providing other avenues for people to receive information. All of these combine to improve business continuity and resiliency.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Froemyr, E.; Berteussen, K.A.; Jahren, L.

    Small scale seismic surveys have the potential of providing low-cost high resolution subsurface images of limited targets. Crucial to the success of this method is to understand the character and level of ambient noise. Based on this understanding appropriate source strength and receiver fold can be determined in order to obtain the necessary signal to noise ratio at target depth. Saga Petroleum a.s. and Read Well Services A/S performed a test off-shore Norway using geophones on the seabed. The receivers consisted of two small geophone arrays separated by 1 km. A 3 km line was host symmetrically above the receivermore » arrays. The line was shot in a non-continuous fashion by moving from one position to the next with 5 repetitive shots fired at each shot position. A small airgun array was used. A large proportion of the noise exhibits clear spatial coherence. The most significant noise sources are the receiver vessel and the shooting boat. Spectral and spatial analysis reveals that additional sources of noise are present including subsurface sources. The target reflector was top reservoir at approximately 2.1 sec. two-way time. With 4 geophones in each array and repetitive shooting, top reservoir is visible but weak. The area is in general complex but the authors may infer that reduce vessel noise coupled with increased source strength can provide a high resolution subsurface image revealing details not seen on the standard marine seismic section.« less

  18. Technology transfer: Transportation

    NASA Technical Reports Server (NTRS)

    Anyos, T.; Christy, L.; Lizak, R.; Wilhelm, J.

    1978-01-01

    The successful application of aerospace technology to problems related to highways and rail and rapid transit systems is described with emphasis on the use of corrosion resistant paints, fire retardant materials, and law enforcement. Possible areas for the use of spinoff from NASA technology by the California State Department of Corrections are identified. These include drug detection, security and warning systems, and the transportation and storage of food. A communication system for emergency services is also described.

  19. Remote monitoring of a Fire Protection System

    NASA Astrophysics Data System (ADS)

    Bauman, Steven; Vermeulen, Tom; Roberts, Larry; Matsushige, Grant; Gajadhar, Sarah; Taroma, Ralph; Elizares, Casey; Arruda, Tyson; Potter, Sharon; Hoffman, James

    2011-03-01

    Some years ago CFHT proposed developing a Remote Observing Environment aimed at producing Science Observations at their Observatory Facility on Mauna Kea from their Headquarters facility in Waimea, HI. This Remote Observing Project commonly referred to as OAP (Observatory Automation Project) was completed at the end of January 2011 and has been providing the majority of Science Data since. My poster will discuss the upgrades to the existing fire alarm protection system. With no one at the summit during nightly operations, the observatory facility required automated monitoring of the facility for safety to personnel and equipment in the case of a fire. An addressable analog fire panel was installed which utilizes digital communication protocol (DCP), intelligent communication with other devices, and an RS-232 interface which provides feedback and real-time monitoring of the system. Using the interface capabilities of the panel, it provides notifications when heat detectors, smoke sensors, manual pull stations, or the main observatory computer room fire suppression system has been activated. The notifications are sent out as alerts to staff in the form of test massages and emails and the observing control GUI interface alerts the remote telescope operator with a map showing the location of the fire occurrence and type of device that has been triggered. And all of this was accomplished without the need for an outside vendor to monitor the system and facilitate warnings or notifications regarding the system.

  20. 3D tomographic seismic imaging of the southern rupture barrier of the great Sumatra-Andaman 2005 earthquake

    NASA Astrophysics Data System (ADS)

    Vermeesch, P. M.; Henstock, T. J.; Lange, D.; McNeill, L. C.; Barton, P. J.; Tang, G.; Bull, J. M.; Tilmann, F.; Dean, S. M.; Djajadihardja, Y.; Permana, H.

    2009-04-01

    In 2008 a 3D onshore-offshore controlled-source seismic experiment was carried out in an area of 300 km x 400 km, centered on the southern termination of the great Sumatra-Andaman 2005 earthquake rupture. In the first part of cruise SO198 on R/V Sonne ~10000 airgun shots were fired into an array of 47 Ocean Bottom Seismometers (OBSs). A further ~50000 shots were fired into an array of 10 long-deployment OBSs. All shots were recorded on ~15 seismometers on the islands and more than 20 seismometers along the coast of Sumatra. An initial velocity model has been derived from 70132 first-arrival traveltimes from 45 OBSs, using the First-Arrival Seismic Tomography (FAST) inversion code developed by Zelt and Barton (1998). Root Mean Square traveltime misfit reduces from 1311 ms in the 1D starting model to 81 ms after 20 non-linear iterations. Offsets range between 0 and 265 km, with rays penetrating up to 28 km depth in the final model, hereby imaging the top of the subducting oceanic plate and revealing its complex 3D topography. Ray coverage is still being extended by including first-arrival traveltime picks from the landstations on the coast of Sumatra and the islands and from the 10 long-term deployment OBSs that will be recovered in January. The robustness and resolution of the final 3D model is examined by exploring different starting models, different inversion parameters and by carrying out checkerboard tests and synthetic tests. The resulting crustal 3D velocity model will allow us to explore the nature and physical cause of the rupture barrier of the 2005 great earthquake. Comparison with a similar dataset and subsequent 3D velocity model acquired at the boundary between the 2004 and 2005 earthquakes will provide important insights into the segmentation of the Sumatra subduction zone and the dynamics of its great earthquakes. Zelt, C. A. and P. J. Barton (1998). Three-dimensional seismic refraction tomography: A comparison of two methods applied to data from the Faroe Basin. Journal of Geophysical Research 103: 7187-7210.

  1. OpenFIRE - A Web GIS Service for Distributing the Finnish Reflection Experiment Datasets

    NASA Astrophysics Data System (ADS)

    Väkevä, Sakari; Aalto, Aleksi; Heinonen, Aku; Heikkinen, Pekka; Korja, Annakaisa

    2017-04-01

    The Finnish Reflection Experiment (FIRE) is a land-based deep seismic reflection survey conducted between 2001 and 2003 by a research consortium of the Universities of Helsinki and Oulu, the Geological Survey of Finland, and a Russian state-owned enterprise SpetsGeofysika. The dataset consists of 2100 kilometers of high-resolution profiles across the Archaean and Proterozoic nuclei of the Fennoscandian Shield. Although FIRE data have been available on request since 2009, the data have remained underused outside the original research consortium. The original FIRE data have been quality-controlled. The shot gathers have been cross-checked and comprehensive errata has been created. The brute stacks provided by the Russian seismic contractor have been reprocessed into seismic sections and replotted. A complete documentation of the intermediate processing steps is provided together with guidelines for setting up a computing environment and plotting the data. An open access web service "OpenFIRE" for the visualization and the downloading of FIRE data has been created. The service includes a mobile-responsive map application capable of enriching seismic sections with data from other sources such as open data from the National Land Survey and the Geological Survey of Finland. The AVAA team of the Finnish Open Science and Research Initiative has provided a tailored Liferay portal with necessary web components such as an API (Application Programming Interface) for download requests. INSPIRE (Infrastructure for Spatial Information in Europe) -compliant discovery metadata have been produced and geospatial data will be exposed as Open Geospatial Consortium standard services. The technical guidelines of the European Plate Observing System have been followed and the service could be considered as a reference application for sharing reflection seismic data. The OpenFIRE web service is available at www.seismo.helsinki.fi/openfire

  2. Role of MODIS Vegetation Phenology Products in the ForWarn System for Monitoring of Forest Disturbances in the Conterminous United States

    NASA Astrophysics Data System (ADS)

    Spruce, J.; Hargrove, W. W.; Norman, S.; Gasser, J.; Smoot, J.; Kuper, P.

    2012-12-01

    This presentation discusses MODIS vegetation phenology products used in the ForWarn Early Warning System (EWS) tool for near real time regional forest disturbance detection and surveillance at regional to national scales. The ForWarn EWS is being developed by the USDA Forest Service NASA, ORNL, and USGS to aid federal and state forest health management activities. ForWarn employs multiple historical land surface phenology products that are derived from MODIS MOD13 Normalized Difference Vegetation Index (NDVI) data. The latter is temporally processed into phenology products with the Time Series Product Tool (TSPT) and the Phenological Parameter Estimation Tool (PPET) software produced at NASA Stennis Space Center. TSPT is used to effectively noise reduce, fuse, and void interpolate MODIS NDVI data. PPET employs TSPT-processed NDVI time series data as an input, outputting multiple vegetation phenology products at a 232 meter resolution for 2000 to 2011, including NDVI magnitude and day of year products for seven key points along the growing season (peak of growing season and the minima, 20%, and 80% of the peak NDVI for both the left and right side of growing season), cumulative NDVI integral products for the most active part of the growing season and sequentially across the growing season at 8 day intervals, and maximum value NDVI products composited at 24 day intervals in which each product date has 8 days of overlap between the previous and following product dates. MODIS NDVI phenology products are also used to compute nationwide near real time forest change products every 8 days. These include percent change in forest NDVI products that compare the current NDVI from USGS eMODIS products to historical MODIS MOD13 NDVI. For each date, three forest change products are produced using three different maximum value NDVI baselines (from the previous year, three previous years, and all previous years). All change products are output with a rainbow color table in which forests with the most severe NDVI decreases are assigned hot colors (yellow to red) and forests with prominent NDVI increases are assigned cold colors (blue tones). All mentioned products have been integrated as data layers into ForWarn's geospatial data viewer known as the U.S. Forest Change Assessment Viewer (FCAV). The latter is used to view and assess the context of the mentioned forest change products with respect to ancillary data layers, such as land cover, elevation, hydrologic features, climatic data, storm data, aerial disturbance surveys, fire data, and land ownership. The FCAV also includes a temporal NDVI profiler for viewing phenological change in multi-year NDVI associated with known or suspected regionally apparent forest disturbances (e.g., from fire and insects). ForWarn forest change products have been used to detect, track, and assess several biotic and abiotic regional forest disturbance events across the country, including ephemeral and longer lasting damage from storms, drought, and insects. Such change products are most effective for viewing severe disturbance patches of multiple pixels. MODIS vegetation phenology products contribute vital current information on forest conditions to the ForWarn system and this role is expected to grow as these products are refined and derivative products are added.

  3. Role of MODIS Vegetation Phenology Products in the ForWarn System for Monitoring of Forest Disturbances in the Conterminous United States

    NASA Technical Reports Server (NTRS)

    Spruce, Joseph P.; Hargrove, William; Norman, Steve; Gasser, Jerry; Smoot, James; Kuper, Philip D,

    2012-01-01

    This presentation discusses MODIS vegetation phenology products used in the ForWarn Early Warning System (EWS) tool for near real time regional forest disturbance detection and surveillance at regional to national scales. The ForWarn EWS is being developed by the USDA Forest Service NASA, ORNL, and USGS to aid federal and state forest health management activities. ForWarn employs multiple historical land surface phenology products that are derived from MODIS MOD13 Normalized Difference Vegetation Index (NDVI) data. The latter is temporally processed into phenology products with the Time Series Product Tool (TSPT) and the Phenological Parameter Estimation Tool (PPET) software produced at NASA Stennis Space Center. TSPT is used to effectively noise reduce, fuse, and void interpolate MODIS NDVI data. PPET employs TSPT-processed NDVI time series data as an input, outputting multiple vegetation phenology products at a 232 meter resolution for 2000 to 2011, including NDVI magnitude and day of year products for seven key points along the growing season (peak of growing season and the minima, 20%, and 80% of the peak NDVI for both the left and right side of growing season), cumulative NDVI integral products for the most active part of the growing season and sequentially across the growing season at 8 day intervals, and maximum value NDVI products composited at 24 day intervals in which each product date has 8 days of overlap between the previous and following product dates. MODIS NDVI phenology products are also used to compute nationwide NRT forest change products refreshed every 8 days. These include percent change in forest NDVI products that compare the current NDVI from USGS eMODIS products to historical MODIS MOD13 NDVI. For each date, three forest change products are produced using three different maximum value NDVI baselines (from the previous year, three previous years, and all previous years). All change products are output with a rainbow color table in which forests with the most severe NDVI decreases are assigned hot colors (yellow to red) and forests with prominent NDVI increases are assigned cold colors (blue tones). All mentioned products have been integrated as data layers into ForWarn s geospatial data viewer known as the U.S. Forest Change Assessment Viewer (FCAV). The latter is used to view and assess the context of the mentioned forest change products with respect to ancillary data layers, such as land cover, elevation, hydrologic features, climatic data, storm data, aerial disturbance surveys, fire data, and land ownership. The FCAV also includes a temporal NDVI profiler for viewing phenological change in multi-year NDVI associated with known or suspected regionally apparent forest disturbances (e.g., from fire and insects). ForWarn forest change products have been used to detect, track, and assess several biotic and abiotic regional forest disturbance events across the country, including ephemeral and longer lasting damage from storms, drought, and insects. Such change products are most effective for viewing severe disturbances affecting multiple MODIS pixels. MODIS vegetation phenology products contribute vital current information on forest conditions to the ForWarn system and this role is expected to grow as these products are refined and derivative products are added.

  4. AEGIS: a wildfire prevention and management information system

    NASA Astrophysics Data System (ADS)

    Kalabokidis, K.; Ager, A.; Finney, M.; Athanasis, N.; Palaiologou, P.; Vasilakos, C.

    2015-10-01

    A Web-GIS wildfire prevention and management platform (AEGIS) was developed as an integrated and easy-to-use decision support tool (http://aegis.aegean.gr). The AEGIS platform assists with early fire warning, fire planning, fire control and coordination of firefighting forces by providing access to information that is essential for wildfire management. Databases were created with spatial and non-spatial data to support key system functionalities. Updated land use/land cover maps were produced by combining field inventory data with high resolution multispectral satellite images (RapidEye) to be used as inputs in fire propagation modeling with the Minimum Travel Time algorithm. End users provide a minimum number of inputs such as fire duration, ignition point and weather information to conduct a fire simulation. AEGIS offers three types of simulations; i.e. single-fire propagations, conditional burn probabilities and at the landscape-level, similar to the FlamMap fire behavior modeling software. Artificial neural networks (ANN) were utilized for wildfire ignition risk assessment based on various parameters, training methods, activation functions, pre-processing methods and network structures. The combination of ANNs and expected burned area maps produced an integrated output map for fire danger prediction. The system also incorporates weather measurements from remote automatic weather stations and weather forecast maps. The structure of the algorithms relies on parallel processing techniques (i.e. High Performance Computing and Cloud Computing) that ensure computational power and speed. All AEGIS functionalities are accessible to authorized end users through a web-based graphical user interface. An innovative mobile application, AEGIS App, acts as a complementary tool to the web-based version of the system.

  5. AEGIS: a wildfire prevention and management information system

    NASA Astrophysics Data System (ADS)

    Kalabokidis, Kostas; Ager, Alan; Finney, Mark; Athanasis, Nikos; Palaiologou, Palaiologos; Vasilakos, Christos

    2016-03-01

    We describe a Web-GIS wildfire prevention and management platform (AEGIS) developed as an integrated and easy-to-use decision support tool to manage wildland fire hazards in Greece (http://aegis.aegean.gr). The AEGIS platform assists with early fire warning, fire planning, fire control and coordination of firefighting forces by providing online access to information that is essential for wildfire management. The system uses a number of spatial and non-spatial data sources to support key system functionalities. Land use/land cover maps were produced by combining field inventory data with high-resolution multispectral satellite images (RapidEye). These data support wildfire simulation tools that allow the users to examine potential fire behavior and hazard with the Minimum Travel Time fire spread algorithm. End-users provide a minimum number of inputs such as fire duration, ignition point and weather information to conduct a fire simulation. AEGIS offers three types of simulations, i.e., single-fire propagation, point-scale calculation of potential fire behavior, and burn probability analysis, similar to the FlamMap fire behavior modeling software. Artificial neural networks (ANNs) were utilized for wildfire ignition risk assessment based on various parameters, training methods, activation functions, pre-processing methods and network structures. The combination of ANNs and expected burned area maps are used to generate integrated output map of fire hazard prediction. The system also incorporates weather information obtained from remote automatic weather stations and weather forecast maps. The system and associated computation algorithms leverage parallel processing techniques (i.e., High Performance Computing and Cloud Computing) that ensure computational power required for real-time application. All AEGIS functionalities are accessible to authorized end-users through a web-based graphical user interface. An innovative smartphone application, AEGIS App, also provides mobile access to the web-based version of the system.

  6. Driving in traffic: short-range sensing for urban collision avoidance

    NASA Astrophysics Data System (ADS)

    Thorpe, Chuck E.; Duggins, David F.; Gowdy, Jay W.; MacLaughlin, Rob; Mertz, Christoph; Siegel, Mel; Suppe, Arne; Wang, Chieh-Chih; Yata, Teruko

    2002-07-01

    Intelligent vehicles are beginning to appear on the market, but so far their sensing and warning functions only work on the open road. Functions such as runoff-road warning or adaptive cruise control are designed for the uncluttered environments of open highways. We are working on the much more difficult problem of sensing and driver interfaces for driving in urban areas. We need to sense cars and pedestrians and curbs and fire plugs and bicycles and lamp posts; we need to predict the paths of our own vehicle and of other moving objects; and we need to decide when to issue alerts or warnings to both the driver of our own vehicle and (potentially) to nearby pedestrians. No single sensor is currently able to detect and track all relevant objects. We are working with radar, ladar, stereo vision, and a novel light-stripe range sensor. We have installed a subset of these sensors on a city bus, driving through the streets of Pittsburgh on its normal runs. We are using different kinds of data fusion for different subsets of sensors, plus a coordinating framework for mapping objects at an abstract level.

  7. Civil Applications of National Satellites

    NASA Astrophysics Data System (ADS)

    Killam, Dudley B.

    2002-01-01

    For over thirty years, the United States Air Force has employed infrared surveillance for missile warning purposes in support of peace. The Defense Support Program, currently employed in this way, consists of a constellation of satellites that provide civil-oriented, peace preserving infrared surveillance. Such civil applications include monitoring parched areas for wind-whipped brush fires or lightning-initiated forest fires that consume many acres of timber and threaten populated areas. Other applications include the similar monitoring of static, infrared-sensed heat sources including volcanoes and the plumes of acrid smoke produced when the volcanoes are active. This paper will address these important missions that can be performed by the national infrared surveillance satellite constellations, furthering the peace of the world in ways never envisioned by their creators 30 years ago.

  8. E-cigarette use in patients receiving home oxygen therapy.

    PubMed

    Lacasse, Yves; Légaré, Martin; Maltais, François

    2015-01-01

    Current smokers who are prescribed home oxygen may not benefit from the therapy. In addition to being an obvious fire hazard, there is some evidence that the physiological mechanisms by which home oxygen is believed to operate are inhibited by smoking. Although their effectiveness is yet to be demonstrated, electronic cigarettes (e-cigarettes) are often regarded as an aid to smoking cessation. However, several burn accidents in e-cigarette smokers receiving home oxygen therapy have also been reported, leading Health Canada to release a warning of fire risk to oxygen therapy patients from e-cigarettes. It is the authors' position that patients receiving oxygen should definitely not use e-cigarettes. The authors provide suggestions for addressing the delicate issue of home oxygen therapy in current cigarette and⁄or e-cigarette smokers.

  9. Emergency assessment of post-fire debris-flow hazards for the 2013 Powerhouse fire, southern California

    USGS Publications Warehouse

    Staley, Dennis M.; Smoczyk, Gregory M.; Reeves, Ryan R.

    2013-01-01

    Wildfire dramatically alters the hydrologic response of a watershed such that even modest rainstorms can produce dangerous flash floods and debris flows. Existing empirical models were used to predict the probability and magnitude of debris-flow occurrence in response to a 10-year recurrence interval rainstorm for the 2013 Powerhouse fire near Lancaster, California. Overall, the models predict a relatively low probability for debris-flow occurrence in response to the design storm. However, volumetric predictions suggest that debris flows that occur may entrain a significant volume of material, with 44 of the 73 basins identified as having potential debris-flow volumes between 10,000 and 100,000 cubic meters. These results suggest that even though the likelihood of debris flow is relatively low, the consequences of post-fire debris-flow initiation within the burn area may be significant for downstream populations, infrastructure, and wildlife and water resources. Given these findings, we recommend that residents, emergency managers, and public works departments pay close attention to weather forecasts and National-Weather-Service-issued Debris Flow and Flash Flood Outlooks, Watches, and Warnings and that residents adhere to any evacuation orders.

  10. Olfaction: New Understandings, Diagnostic Applications.

    PubMed

    Ruggiero, Gabrielle F; Wick, Jeannette Y

    2016-11-01

    Estimates indicate that 14 million Americans have olfactory dysfunction. As with other senses, such as sight and hearing, olfaction frequently declines with age. Impaired olfaction can be a warning sign of Parkinson's disease, sometimes occurring before motor symptoms develop. It's also an initial symptom of Alzheimer's dementia (AD); the amyloid plaques and tangles characterizing AD invade the olfactory bulb and hippocampus early in its course, hampering odor identification. Olfactory dysfunction is associated with some serious problems, including inability to smell warning odors (fire, gas) and impaired ability to taste food. Standardized, validated methods are available to measure several different dimensions of olfactory function, including odor identification, discrimination, and threshold levels. Researchers are currently studying the unique olfactory deficits associated with different conditions in hopes of identifying new, noninvasive tools for early diagnosis and treatment. Drugs may cause or contribute to olfactory dysfunction, but it can be difficult to pinpoint offending medications.

  11. Risk analysis procedure for post-wildfire natural hazards in British Columbia

    NASA Astrophysics Data System (ADS)

    Jordan, Peter

    2010-05-01

    Following a severe wildfire season in 2003, and several subsequent damaging debris flow and flood events, the British Columbia Forest Service developed a procedure for analysing risks to public safety and infrastructure from such events. At the same time, the Forest Service undertook a research program to determine the extent of post-wildfire hazards, and examine the hydrologic and geomorphic processes contributing to the hazards. The risk analysis procedure follows the Canadian Standards Association decision-making framework for risk management (which in turn is based on international standards). This has several steps: identification of risk, risk analysis and estimation, evaluation of risk tolerability, developing control or mitigation strategies, and acting on these strategies. The Forest Service procedure deals only with the first two steps. The results are passed on to authorities such as the Provincial Emergency Program and local government, who are responsible for evaluating risks, warning residents, and applying mitigation strategies if appropriate. The objective of the procedure is to identify and analyse risks to public safety and infrastructure. The procedure is loosely based on the BAER (burned area emergency response) program in the USA, with some important differences. Our procedure focuses on identifying risks and warning affected parties, not on mitigation activities such as broadcast erosion control measures. Partly this is due to limited staff and financial resources. Also, our procedure is not multi-agency, but is limited to wildfires on provincial forest land; in British Columbia about 95% of forest land is in the publicly-owned provincial forest. Each fire season, wildfires are screened by size and proximity to values at risk such as populated areas. For selected fires, when the fire is largely contained, the procedure begins with an aerial reconnaissance of the fire, and photography with a hand-held camera, which can be used to make a preliminary map of vegetation burn severity if desired. The next steps include mapping catchment boundaries, field traverses to collect data on soil burn severity and water repellency, identification of unstable hillslopes and channels, and inspection of values at risk from hazards such as debris flows or flooding. BARC (burned area reflectance classification) maps based on satellite imagery are prepared for some fires, although these are typically not available for several weeks. Our objective is to make a preliminary risk analysis report available about two weeks after the fire is contained. If high risks to public safety or infrastructure are identified, the risk analysis reports may make recommendations for mitigation measures to be considered; however, acting on these recommendations is the responsibility of local land managers, local government, or landowners. Mitigation measures for some fires have included engineering treatments to reduce the hydrologic impact of logging roads, protective structures such as dykes or berms, and straw mulching to reduce runoff and erosion on severely burned areas. The Terrace Mountain Fire, with burned 9000 hectares in the Okanagan Valley in 2009, is used as an example of the application of the procedure.

  12. OPERATION SUNBEAM, SHOT SMALL BOY. Project Officer’s Report. Project 2.9. Fallout Collection and Gross Sample Analysis

    DTIC Science & Technology

    1985-09-01

    concepts for large scale radiological defense operations. 2. 212 CP 2 PR0c J 2.1 PLAJWU This project participated in the single shotp A Boy, fired on a...inch diameter by 3 inch high NaI scintilla- tion counter taking sample tubes up to 1-1/4 inches in diameter. -The crystal was mounted on an W type...inch high Nal scin- tillation counter. The crystal -source distance was 8-3/4 inches. Shielding consisted of a lead cylinder 2 inches thick, 7 inches

  13. A proposed standard methodology for estimating the wounding capacity of small calibre projectiles or other missiles.

    PubMed

    Berlin, R H; Janzon, B; Rybeck, B; Schantz, B; Seeman, T

    1982-01-01

    A standard methodology for estimating the energy transfer characteristics of small calibre bullets and other fast missiles is proposed, consisting of firings against targets made of soft soap. The target is evaluated by measuring the size of the permanent cavity remaining in it after the shot. The method is very simple to use and does not require access to any sophisticated measuring equipment. It can be applied under all circumstances, even under field conditions. Adequate methods of calibration to ensure good accuracy are suggested. The precision and limitations of the method are discussed.

  14. [The forensic medical significance of the igniting primer for the 18×45T cartridges of the 'Osa' pistol].

    PubMed

    Leonov, S V; Pinchuk, P V; Rasnyuk, S V

    The objective of the present study was to obtain the ballistic characteristics of the igniting primer (electrical ignitor) for the 18×45T cartridges of the 'Osa' pistol produced by different manufacturers. The experiments included a series of shots fired from the 'Osa' pistol with the use of cartridges having an energy of 85 Joules ('Novye oruzheinye tekhnologii', Ltd., Sergiev Posad) and 88 Joules ('A+A', Ltd, Tula). The shooting distance varied from the point blank range to 5, 10, 20, 30, 40, and 50 cm. The targets were either the femoral soft tissue of the cut-off human lower extremity, white cotton fabric, and the 1-5 cm high gelatin cylinder 25 cm in diameter. The experiments have demonstrated that the igniting primer (electrical ignitor) for the cartridges manufactured by the 'Novye oruzheinye tekhnologii', Ltd., Sergiev Posad, served as an additional factor of the shot responsible for the penetrating power of the ammunition at a distance of 50 cm. The data on the composition of metals used for the manufacturing of the igniting primers under consideration are presented.

  15. Seismic experiments on Showa-Shinzan lava dome using firework shots

    NASA Astrophysics Data System (ADS)

    Miyamachi, Hiroki; Watanabe, Hidefumi; Moriya, Takeo; Okada, Hiromu

    1987-11-01

    Seismic experiments were conducted on Showa-Shinzan, a parasitic lava dome of volcano Usu, Hokkaido, which was formed during 1943 1945 activity. Since we found that firework shots fired on the ground can effectively produce seismic waves, we placed many seismometers on and around the dome during the summer festivals in 1984 and 1985. The internal structure had been previously studied using a prospecting technique employing dynamite blasts in 1954. The measured interval velocity across the dome in 1984 ranges 1.8 2.2 km/s drastically low compared to the results (3.0 4.0 km/s) in 1954; in addition, the velocity is 0.3 0.5 km/s higher than that in the surrounding area. The variation of the observed first arrival amplitudes can be explained by geometrical spreading in the high velocity lava dome. These observations show a marked change in the internal physical state of the dome corresponding to a drop in the measured highest temperature at fumaroles on the dome from 800°C in 1947 to 310°C in 1986.

  16. Highly Sensitive Sensors Based on Metal-Oxide Nanocolumns for Fire Detection.

    PubMed

    Lee, Kwangjae; Shim, Young-Seok; Song, Young Geun; Han, Soo Deok; Lee, Youn-Sung; Kang, Chong-Yun

    2017-02-07

    A fire detector is the most important component in a fire alarm system. Herein, we present the feasibility of a highly sensitive and rapid response gas sensor based on metal oxides as a high performance fire detector. The glancing angle deposition (GLAD) technique is used to make the highly porous structure such as nanocolumns (NCs) of various metal oxides for enhancing the gas-sensing performance. To measure the fire detection, the interface circuitry for our sensors (NiO, SnO₂, WO₃ and In₂O₃ NCs) is designed. When all the sensors with various metal-oxide NCs are exposed to fire environment, they entirely react with the target gases emitted from Poly(vinyl chlorides) (PVC) decomposed at high temperature. Before the emission of smoke from the PVC (a hot-plate temperature of 200 °C), the resistances of the metal-oxide NCs are abruptly changed and SnO₂ NCs show the highest response of 2.1. However, a commercial smoke detector did not inform any warning. Interestingly, although the NiO NCs are a p -type semiconductor, they show the highest response of 577.1 after the emission of smoke from the PVC (a hot-plate temperature of 350 °C). The response time of SnO₂ NCs is much faster than that of a commercial smoke detector at the hot-plate temperature of 350 °C. In addition, we investigated the selectivity of our sensors by analyzing the responses of all sensors. Our results show the high potential of a gas sensor based on metal-oxide NCs for early fire detection.

  17. Fringe-jump corrected far infrared tangential interferometer/polarimeter for a real-time density feedback control system of NSTX plasmasa)

    NASA Astrophysics Data System (ADS)

    Juhn, J.-W.; Lee, K. C.; Hwang, Y. S.; Domier, C. W.; Luhmann, N. C.; Leblanc, B. P.; Mueller, D.; Gates, D. A.; Kaita, R.

    2010-10-01

    The far infrared tangential interferometer/polarimeter (FIReTIP) of the National Spherical Torus Experiment (NSTX) has been set up to provide reliable electron density signals for a real-time density feedback control system. This work consists of two main parts: suppression of the fringe jumps that have been prohibiting the plasma density from use in the direct feedback to actuators and the conceptual design of a density feedback control system including the FIReTIP, control hardware, and software that takes advantage of the NSTX plasma control system (PCS). By investigating numerous shot data after July 2009 when the new electronics were installed, fringe jumps in the FIReTIP are well characterized, and consequently the suppressing algorithms are working properly as shown in comparisons with the Thomson scattering diagnostic. This approach is also applicable to signals taken at a 5 kHz sampling rate, which is a fundamental constraint imposed by the digitizers providing inputs to the PCS. The fringe jump correction algorithm, as well as safety and feedback modules, will be included as submodules either in the gas injection system category or a new category of density in the PCS.

  18. MyEEW: A Smartphone App for the ShakeAlert System

    NASA Astrophysics Data System (ADS)

    Strauss, J. A.; Allen, S.; Allen, R. M.; Hellweg, M.

    2015-12-01

    Earthquake Early Warning (EEW) is a system that can provide a few to tens of seconds warning prior to ground shaking at a user's location. The goal and purpose of such a system is to reduce, or minimize, the damage, costs, and casualties resulting from an earthquake. A demonstration earthquake early warning system (ShakeAlert) is undergoing testing in the United States by the UC Berkeley Seismological Laboratory, Caltech, ETH Zurich, University of Washington, the USGS, and beta users in California and the Pacific Northwest. The UC Berkeley Seismological Laboratory has created a smartphone app called MyEEW, which interfaces with the ShakeAlert system to deliver early warnings to individual users. Many critical facilities (transportation, police, and fire) have control rooms, which could run a centralized interface, but our ShakeAlert Beta Testers have also expressed their need for mobile options. This app augments the basic ShakeAlert Java desktop applet by allowing workers off-site (or merely out of hearing range) to be informed of coming hazards. MyEEW receives information from the ShakeAlert system to provide users with real-time information about shaking that is about to happen at their individual location. It includes a map, timer, and earthquake information similar to the Java desktop User Display. The app will also feature educational material to help users craft their own response and resiliency strategies. The app will be open to UC Berkeley Earthquake Research Affiliates members for testing in the near future.

  19. Indonesian fire activity and smoke pollution in 2015 show persistent nonlinear sensitivity to El Niño-induced drought.

    PubMed

    Field, Robert D; van der Werf, Guido R; Fanin, Thierry; Fetzer, Eric J; Fuller, Ryan; Jethva, Hiren; Levy, Robert; Livesey, Nathaniel J; Luo, Ming; Torres, Omar; Worden, Helen M

    2016-08-16

    The 2015 fire season and related smoke pollution in Indonesia was more severe than the major 2006 episode, making it the most severe season observed by the NASA Earth Observing System satellites that go back to the early 2000s, namely active fire detections from the Terra and Aqua Moderate Resolution Imaging Spectroradiometers (MODIS), MODIS aerosol optical depth, Terra Measurement of Pollution in the Troposphere (MOPITT) carbon monoxide (CO), Aqua Atmospheric Infrared Sounder (AIRS) CO, Aura Ozone Monitoring Instrument (OMI) aerosol index, and Aura Microwave Limb Sounder (MLS) CO. The MLS CO in the upper troposphere showed a plume of pollution stretching from East Africa to the western Pacific Ocean that persisted for 2 mo. Longer-term records of airport visibility in Sumatra and Kalimantan show that 2015 ranked after 1997 and alongside 1991 and 1994 as among the worst episodes on record. Analysis of yearly dry season rainfall from the Tropical Rainfall Measurement Mission (TRMM) and rain gauges shows that, due to the continued use of fire to clear and prepare land on degraded peat, the Indonesian fire environment continues to have nonlinear sensitivity to dry conditions during prolonged periods with less than 4 mm/d of precipitation, and this sensitivity appears to have increased over Kalimantan. Without significant reforms in land use and the adoption of early warning triggers tied to precipitation forecasts, these intense fire episodes will reoccur during future droughts, usually associated with El Niño events.

  20. Indonesian fire activity and smoke pollution in 2015 show persistent nonlinear sensitivity to El Niño-induced drought

    NASA Astrophysics Data System (ADS)

    Field, Robert D.; van der Werf, Guido R.; Fanin, Thierry; Fetzer, Eric J.; Fuller, Ryan; Jethva, Hiren; Levy, Robert; Livesey, Nathaniel J.; Luo, Ming; Torres, Omar; Worden, Helen M.

    2016-08-01

    The 2015 fire season and related smoke pollution in Indonesia was more severe than the major 2006 episode, making it the most severe season observed by the NASA Earth Observing System satellites that go back to the early 2000s, namely active fire detections from the Terra and Aqua Moderate Resolution Imaging Spectroradiometers (MODIS), MODIS aerosol optical depth, Terra Measurement of Pollution in the Troposphere (MOPITT) carbon monoxide (CO), Aqua Atmospheric Infrared Sounder (AIRS) CO, Aura Ozone Monitoring Instrument (OMI) aerosol index, and Aura Microwave Limb Sounder (MLS) CO. The MLS CO in the upper troposphere showed a plume of pollution stretching from East Africa to the western Pacific Ocean that persisted for 2 mo. Longer-term records of airport visibility in Sumatra and Kalimantan show that 2015 ranked after 1997 and alongside 1991 and 1994 as among the worst episodes on record. Analysis of yearly dry season rainfall from the Tropical Rainfall Measurement Mission (TRMM) and rain gauges shows that, due to the continued use of fire to clear and prepare land on degraded peat, the Indonesian fire environment continues to have nonlinear sensitivity to dry conditions during prolonged periods with less than 4 mm/d of precipitation, and this sensitivity appears to have increased over Kalimantan. Without significant reforms in land use and the adoption of early warning triggers tied to precipitation forecasts, these intense fire episodes will reoccur during future droughts, usually associated with El Niño events.

  1. Indonesian Fire Activity and Smoke Pollution in 2015 Show Persistent Nonlinear Sensitivity to El Niño-induced Drought

    NASA Technical Reports Server (NTRS)

    Field, Robert D.; van der Werf, Guido R.; Fanin, Thierry; Fetzer, Eric; Fuller, Ryan; Jethva, Hiren; Levy, Robert; Livesey, Nathaniel; Luo, Ming; Torres, Omar; hide

    2016-01-01

    The 2015 fire season and related smoke pollution in Indonesia was more severe than the major 2006 episode, making it the most severe season observed by the NASA Earth Observing System satellites that go back to the early 2000s, namely active fire detections from the Terra and Aqua Moderate Resolution Imaging Spectroradiometers (MODIS), MODIS aerosol optical depth, Terra Measurement of Pollution in the Troposphere (MOPITT) carbon monoxide (CO), Aqua Atmospheric Infrared Sounder (AIRS) CO, Aura Ozone Monitoring Instrument (OMI) aerosol index, and Aura Microwave Limb Sounder (MLS) CO. The MLS CO in the upper troposphere showed a plume of pollution stretching from East Africa to the western Pacific Ocean that persisted for two months. Longer-term records of airport visibility in Sumatra and Kalimantan show that 2015 ranked after 1997 and alongside 1991 and 1994 as among the worst episodes on record. Analysis of yearly dry season rainfall from the Tropical Rainfall Measurement Mission (TRMM) and rain gauges shows that, due to the continued use of fire to clear and prepare land on degraded peat, the Indonesian fire environment continues to have non-linear sensitivity to dry conditions during prolonged periods with less than 4mmday of precipitation, and this sensitivity appears to have increased over Kalimantan. Without significant reforms in land use and the adoption of early warning triggers tied to precipitation forecasts, these intense fire episodes will re-occur during future droughts, usually associated with El Nio events.

  2. Indonesian fire activity and smoke pollution in 2015 show persistent nonlinear sensitivity to El Niño-induced drought

    PubMed Central

    Field, Robert D.; van der Werf, Guido R.; Fanin, Thierry; Fetzer, Eric J.; Fuller, Ryan; Jethva, Hiren; Levy, Robert; Livesey, Nathaniel J.; Luo, Ming; Torres, Omar; Worden, Helen M.

    2016-01-01

    The 2015 fire season and related smoke pollution in Indonesia was more severe than the major 2006 episode, making it the most severe season observed by the NASA Earth Observing System satellites that go back to the early 2000s, namely active fire detections from the Terra and Aqua Moderate Resolution Imaging Spectroradiometers (MODIS), MODIS aerosol optical depth, Terra Measurement of Pollution in the Troposphere (MOPITT) carbon monoxide (CO), Aqua Atmospheric Infrared Sounder (AIRS) CO, Aura Ozone Monitoring Instrument (OMI) aerosol index, and Aura Microwave Limb Sounder (MLS) CO. The MLS CO in the upper troposphere showed a plume of pollution stretching from East Africa to the western Pacific Ocean that persisted for 2 mo. Longer-term records of airport visibility in Sumatra and Kalimantan show that 2015 ranked after 1997 and alongside 1991 and 1994 as among the worst episodes on record. Analysis of yearly dry season rainfall from the Tropical Rainfall Measurement Mission (TRMM) and rain gauges shows that, due to the continued use of fire to clear and prepare land on degraded peat, the Indonesian fire environment continues to have nonlinear sensitivity to dry conditions during prolonged periods with less than 4 mm/d of precipitation, and this sensitivity appears to have increased over Kalimantan. Without significant reforms in land use and the adoption of early warning triggers tied to precipitation forecasts, these intense fire episodes will reoccur during future droughts, usually associated with El Niño events. PMID:27482096

  3. Smokey Bear is Dead: A New Era of Wildfires in the Western U.S

    NASA Astrophysics Data System (ADS)

    Pierce, J. L.; Duffin, J.; Lindquist, E.; Wuerzer, T.; Pellant, M.

    2013-12-01

    High fuel densities, combined with increasingly severe drought, make the western US highly susceptible to changes in the timing of snowmelt and increases in the length of the fire season. The forests and rangelands of Idaho are especially prone to wildfire; in 2012, over 1.7 million acres burned across Idaho, more acres than in any other state. Climate change is projected to increase summer temperatures and decrease summer precipitation in Idaho, and a drier, warmer, and more variable climate will increase the risk of stand-replacing fires. While infrastructure and alert systems are in place to warn residents about threats from hurricanes, floods and tornados, there is limited protection for communities in the ';fire-plain.' Part of this lack of preparation may stem from the belief that fires can be prevented or stopped; a perception that has been perpetuated by ';Smokey Bear,' and the generally successful interval of fire suppression during the 1960's-1980's. However, in the mid-1980's, severe drought, rising temperatures, and early snowmelt have brought an era of ';mega-fires' to the American West. Periods of recurring high wildfire activity across the western US are not unprecedented in the paleo-record, but the frequency of large fires (> 400 ha) and the annual area burned have increased in the modern. For example, in the past 10 years in Idaho, 17 fires burned over 100,000 acres each: six of those fires occurred in 2012. Likewise, the size and severity of rangeland fires in the Western U.S. has increased by almost an order of magnitude in recent decades; in the early 1980's, range fire extents over 100,000 acres was unheard of, but has become increasingly common in recent years (Pellant, 2013). Boise State University's departments of Geoscience, Community and Regional Planning, and the Public Policy Center are examining the risks and impacts of fire along the Boise WUI. The research integrates the perspectives of the geosciences and social sciences by combining physically-based fire hazards, effective fire management policies, and Planning in the West.

  4. Study on Climate and Grassland Fire in HulunBuir, Inner Mongolia Autonomous Region, China

    PubMed Central

    Liu, Meifang; Zhao, Jianjun; Guo, Xiaoyi; Zhang, Zhengxiang; Tan, Gang; Yang, Jihong

    2017-01-01

    Grassland fire is one of the most important disturbance factors of the natural ecosystem. Climate factors influence the occurrence and development of grassland fire. An analysis of the climate conditions of fire occurrence can form the basis for a study of the temporal and spatial variability of grassland fire. The purpose of this paper is to study the effects of monthly time scale climate factors on the occurrence of grassland fire in HulunBuir, located in the northeast of the Inner Mongolia Autonomous Region in China. Based on the logistic regression method, we used the moderate-resolution imaging spectroradiometer (MODIS) active fire data products named thermal anomalies/fire daily L3 Global 1km (MOD14A1 (Terra) and MYD14A1 (Aqua)) and associated climate data for HulunBuir from 2000 to 2010, and established the model of grassland fire climate index. The results showed that monthly maximum temperature, monthly sunshine hours and monthly average wind speed were all positively correlated with the fire climate index; monthly precipitation, monthly average temperature, monthly average relative humidity, monthly minimum relative humidity and the number of days with monthly precipitation greater than or equal to 5 mm were all negatively correlated with the fire climate index. We used the active fire data from 2011 to 2014 to validate the fire climate index during this time period, and the validation result was good (Pearson’s correlation coefficient was 0.578), which showed that the fire climate index model was suitable for analyzing the occurrence of grassland fire in HulunBuir. Analyses were conducted on the temporal and spatial distribution of the fire climate index from January to December in the years 2011–2014; it could be seen that from March to May and from September to October, the fire climate index was higher, and that the fire climate index of the other months is relatively low. The zones with higher fire climate index are mainly distributed in Xin Barag Youqi, Xin Barag Zuoqi, Zalantun Shi, Oroqen Zizhiqi, and Molidawa Zizhiqi; the zones with medium fire climate index are mainly distributed in Chen Barag Qi, Ewenkizu Zizhiqi, Manzhouli Shi, and Arun Qi; and the zones with lower fire climate index are mainly distributed in Genhe Shi, Ergun city, Yakeshi Shi, and Hailar Shi. The results of this study will contribute to the quantitative assessment and management of early warning and forecasting for mid-to long-term grassland fire risk in HulunBuir. PMID:28304336

  5. Difficult conversations: a national course for neurosurgery residents in physician-patient communication.

    PubMed

    Haglund, Michael M; Rudd, Mariah; Nagler, Alisa; Prose, Neil S

    2015-01-01

    To describe the design, content, implementation, and evaluation of a national curriculum for teaching practical skills in empathic communication to residents in neurosurgery. Based on needs assessed through a national survey of neurosurgery program directors, videotaped scenarios using standardized patients illustrating good and bad communication skills were developed. Presurveys and postsurveys were conducted querying participants on their level of competence and the specific behaviors they would attempt to change following participation. A subgroup of residents was evaluated before and after the training based on videotaped role-play exercises. A pilot study was conducted at the authors' institution and later implemented at National Neurosurgery Boot Camps. A total of 14 Duke graduate medical education neurosurgery residents agreed to participate in the pilot study. From across the country, 93 residents (representing 59 institutions) participated in the communication training as part of the Neurosurgery Boot camps, 11 of whom volunteered to participate in a role-playing session before and after the formal teaching session. Most of the neurosurgery program directors responding to the survey indicated that an interactive online communication-training module would be of value (77%). A total of 93 residents participated in communication training as part of the Neurosurgery Boot Camps. Approximately half of the residents reported having no formal physician-patient communication training. Presurvey and postsurvey results showed significant improvement in several of the communication scenarios. Those who participated in role-play showed significant improvement in "asking open-ended questions," "listening," "fire warning shot," "allowing patient to absorb," and "explaining in clear language." Neurosurgeons frequently participate in difficult conversations. Both residents and faculty note that exposure to this content is suboptimal. A hybrid approach to teaching communication skills is well received and enhances graduate medical education training of surgical subspecialists. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  6. Shot through the heart-firepower and potential lethality of air weapons.

    PubMed

    Bakovic, Marija; Petrovecki, Vedrana; Strinovic, Davor; Mayer, Davor

    2014-11-01

    Although certain air weapons attain muzzle velocities comparable to some firearms, their successful use for committing suicide is rarely seen. Herein, we report a case of a young female died shortly after urgent admission to the hospital with penetrating gunshot wound to the chest. The autopsy revealed perforation of the pericardium and two perforative defects to the right heart ventricle. Injury was inflicted by a 0.177 caliber pellet, fired from an air rifle found near her body. Investigation ruled the death as suicide. The used air rifle fired the pellet with the energy density of 1.9 J/mm(2) , substantially above the threshold for inflicting injury. The pellet penetrated through two layers of cotton fabric and several layers of tissue to inflict fatal injury to the heart. In addition, we provide an insight into the wounding potential of air weapons, which illustrates the need for greater caution in handling those devices. © 2014 American Academy of Forensic Sciences.

  7. Grand challenges in developing a predictive understanding of global fire dynamics

    NASA Astrophysics Data System (ADS)

    Randerson, J. T.; Chen, Y.; Wiggins, E. B.; Andela, N.; Morton, D. C.; Veraverbeke, S.; van der Werf, G.

    2017-12-01

    High quality satellite observations of burned area and fire thermal anomalies over the past two decades have transformed our understanding of climate, ecosystem, and human controls on the spatial and temporal distribution of landscape fires. The satellite observations provide evidence for a rapid and widespread loss of fire from grassland and savanna ecosystems worldwide. Continued expansion of industrial agriculture suggests that observed declines in global burned area are likely to continue in future decades, with profound consequences for ecosystem function and the habitat of many endangered species. Satellite time series also highlight the importance of El Niño-Southern Oscillation and other climate modes as drivers of interannual variability. In many regions, lead times between climate indices and fire activity are considerable, enabling the development of early warning prediction systems for fire season severity. With the recent availability of high-resolution observations from Suomi NPP, Landsat 8, and Sentinel 2, the field of global fire ecology is poised to make even more significant breakthroughs over the next decade. With these new observations, it may be possible to reduce uncertainties in the spatial pattern of burned area by several fold. It is difficult to overstate the importance of these new data constraints for improving our understanding of fire impacts on human health and radiative forcing of climate change. A key research challenge in this context is to understand how the loss of global burned area will affect magnitude of the terrestrial carbon sink and trends in atmospheric composition. Advances in prognostic fire modeling will require new approaches linking agriculture with landscape fire dynamics. A critical need in this context is the development of predictive models of road networks and other drivers of land fragmentation, and a closer integration of fragmentation information with algorithms predicting fire spread. Concurrently, a better representation of the influence of livestock on fuels and fire management is essential for modeling long-term trends. In northern ecosystems, climate-driven changes in lightning ignition may accelerate the northward migration of boreal forests into arctic tundra, increasing the vulnerability of permafrost carbon.

  8. Objective definition of rainfall intensity-duration thresholds for post-fire flash floods and debris flows in the area burned by the Waldo Canyon fire, Colorado, USA

    USGS Publications Warehouse

    Staley, Dennis M.; Gartner, Joseph E.; Kean, Jason W.

    2015-01-01

    We present an objectively defined rainfall intensity-duration (I-D) threshold for the initiation of flash floods and debris flows for basins recently burned in the 2012 Waldo Canyon fire near Colorado Springs, Colorado, USA. Our results are based on 453 rainfall records which include 8 instances of hazardous flooding and debris flow from 10 July 2012 to 14 August 2013. We objectively defined the thresholds by maximizing the number of correct predictions of debris flow or flood occurrence while minimizing the rate of both Type I (false positive) and Type II (false negative) errors. The equation I = 11.6D−0.7 represents the I-D threshold (I, in mm/h) for durations (D, in hours) ranging from 0.083 h (5 min) to 1 h for basins burned by the 2012 Waldo Canyon fire. As periods of high-intensity rainfall over short durations (less than 1 h) produced all of the debris flow and flood events, real-time monitoring of rainfall conditions will result in very short lead times for early-warning. Our results highlight the need for improved forecasting of the rainfall rates during short-duration, high-intensity convective rainfall events.

  9. Probabilistic discrimination between liquid rainfall events, hailstorms, biomass burning and industrial fires from C-Band Radar Polarimetric Variables

    NASA Astrophysics Data System (ADS)

    Valencia, J. M.; Sepúlveda, J.; Hoyos, C.; Herrera, L.

    2017-12-01

    Characterization and identification of fire and hailstorm events using weather radar data in a tropical complex topography region is an important task in risk management and agriculture. Polarimetric variables from a C-Band Dual polarization weather radar have potential uses in particle classification, due to the relationship their sensitivity to shape, spatial orientation, size and fall behavior of particles. In this sense, three forest fires and two chemical fires were identified for the Áburra Valley regions. Measurements were compared between each fire event type and with typical data radar retrievals for liquid precipitation events. Results of this analysis show different probability density functions for each type of event according to the particles present in them. This is very important and useful result for early warning systems to avoid precipitation false alarms during fire events within the study region, as well as for the early detection of fires using radar retrievals in remote cases. The comparative methodology is extended to hailstorm cases. Complementary sensors like laser precipitation sensors (LPM) disdrometers and meteorological stations were used to select dates of solid precipitation occurrence. Then, in this dates weather radar data variables were taken in pixels surrounding the stations and solid precipitation polar values were statistically compared with liquid precipitation values. Spectrum precipitation measured by LPM disdrometer helps to define typical features like particles number, fall velocities and diameters for both precipitation types. In addition, to achieve a complete hailstorm characterization, other meteorological variables were analyzed: wind field from meteorological stations and radar wind profiler, profiling data from Micro Rain Radar (MRR), and thermodynamic data from a microwave radiometer.

  10. ForWarn: A Cross-Cutting Forest Resource Management and Decision Support System Providing the Capacity to Identify and Track Forest Disturbances Nationally

    NASA Astrophysics Data System (ADS)

    Hargrove, W. W.; Spruce, J.; Norman, S.; Christie, W.; Hoffman, F. M.

    2012-12-01

    The Eastern Forest Environmental Threat Assessment Center and Western Wildland Environmental Assessment Center of the USDA Forest Service have collaborated with NASA Stennis Space Center to develop ForWarn, a forest monitoring tool that uses MODIS satellite imagery to produce weekly snapshots of vegetation conditions across the lower 48 United States. Forest and natural resource managers can use ForWarn to rapidly detect, identify, and respond to unexpected changes in the nation's forests caused by insects, diseases, wildfires, severe weather, or other natural or human-caused events. ForWarn detects most types of forest disturbances, including insects, disease, wildfires, frost and ice damage, tornadoes, hurricanes, blowdowns, harvest, urbanization, and landslides. It also detects drought, flood, and temperature effects, and shows early and delayed seasonal vegetation development. Operating continuously since January 2010, results show ForWarn to be a robust and highly capable tool for detecting changes in forest conditions. ForWarn is the first national-scale system of its kind based on remote sensing developed specifically for forest disturbances. It has operated as a prototype since January 2010 and has provided useful information about the location and extent of disturbances detected during the 2011 growing season, including tornadoes, wildfires, and extreme drought. The ForWarn system had an official unveiling and rollout in March 2012, initiated by a joint NASA and USDA press release. The ForWarn home page has had 2,632 unique visitors since rollout in March 2012, with 39% returning visits. ForWarn was used to map tornado scars from the historic April 27, 2011 tornado outbreak, and detected timber damage within more than a dozen tornado tracks across northern Mississippi, Alabama, and Georgia. ForWarn is the result of an ongoing, substantive cooperation among four different government agencies: USDA, NASA, USGS, and DOE. Disturbance maps are available on the web through the ForWarn Change Assessment Viewer at http://forwarn.forestthreats.org/fcav. No user id or password is required, and there is no cost. The Assessment Viewer operates within any popular web browser using nearly any type of computer. It lets users pan, zoom, and scroll around within ForWarn maps, and also contains an up-to-date library of co-registered, near real-time ancillary maps from diverse sources that allows users to assess the nature of particular forest disturbances and ascribe their most-likely causes. Users can check the current week's U.S. Drought Monitor, USGS VegDRI maps, FHM Historical Aerial Disturbance Surveys, MODIS Cumulative Current Year Fire Detections, and many others. A "Share this map" feature lets users save the current map view and extent into a web URL, so that users can easily share what they are looking at inside the Assessment Viewer with others via an email, a document, or a web page. The ForWarn Rapid National Assessment Team examined more than 60 ForWarn forest disturbance events in 2011-2012, and issued over 30 alerts. We hope to automate forest disturbance alerts and supply them through various subscription services. Forest owners and managers would only be alerted to disturbances occurring near their own forest resources.

  11. Value of a dual-polarized gap-filling radar in support of southern California post-fire debris-flow warnings

    USGS Publications Warehouse

    Jorgensen, David P.; Hanshaw, Maiana N.; Schmidt, Kevin M.; Laber, Jayme L; Staley, Dennis M.; Kean, Jason W.; Restrepo, Pedro J.

    2011-01-01

    A portable truck-mounted C-band Doppler weather radar was deployed to observe rainfall over the Station Fire burn area near Los Angeles, California, during the winter of 2009/10 to assist with debris-flow warning decisions. The deployments were a component of a joint NOAA–U.S. Geological Survey (USGS) research effort to improve definition of the rainfall conditions that trigger debris flows from steep topography within recent wildfire burn areas. A procedure was implemented to blend various dual-polarized estimators of precipitation (for radar observations taken below the freezing level) using threshold values for differential reflectivity and specific differential phase shift that improves the accuracy of the rainfall estimates over a specific burn area sited with terrestrial tipping-bucket rain gauges. The portable radar outperformed local Weather Surveillance Radar-1988 Doppler (WSR-88D) National Weather Service network radars in detecting rainfall capable of initiating post-fire runoff-generated debris flows. The network radars underestimated hourly precipitation totals by about 50%. Consistent with intensity–duration threshold curves determined from past debris-flow events in burned areas in Southern California, the portable radar-derived rainfall rates exceeded the empirical thresholds over a wider range of storm durations with a higher spatial resolution than local National Weather Service operational radars. Moreover, the truck-mounted C-band radar dual-polarimetric-derived estimates of rainfall intensity provided a better guide to the expected severity of debris-flow events, based on criteria derived from previous events using rain gauge data, than traditional radar-derived rainfall approaches using reflectivity–rainfall relationships for either the portable or operational network WSR-88D radars. Part of the reason for the improvement was due to siting the radar closer to the burn zone than the WSR-88Ds, but use of the dual-polarimetric variables improved the rainfall estimation by ~12% over the use of traditional Z–R relationships.

  12. Mapping and Analysis of Forest and Land Fire Potential Using Geospatial Technology and Mathematical Modeling

    NASA Astrophysics Data System (ADS)

    Suliman, M. D. H.; Mahmud, M.; Reba, M. N. M.; S, L. W.

    2014-02-01

    Forest and land fire can cause negative implications for forest ecosystems, biodiversity, air quality and soil structure. However, the implications involved can be minimized through effective disaster management system. Effective disaster management mechanisms can be developed through appropriate early warning system as well as an efficient delivery system. This study tried to focus on two aspects, namely by mapping the potential of forest fire and land as well as the delivery of information to users through WebGIS application. Geospatial technology and mathematical modeling used in this study for identifying, classifying and mapping the potential area for burning. Mathematical models used is the Analytical Hierarchy Process (AHP), while Geospatial technologies involved include remote sensing, Geographic Information System (GIS) and digital field data collection. The entire Selangor state was chosen as our study area based on a number of cases have been reported over the last two decades. AHP modeling to assess the comparison between the three main criteria of fuel, topography and human factors design. Contributions of experts directly involved in forest fire fighting operations and land comprising officials from the Fire and Rescue Department Malaysia also evaluated in this model. The study found that about 32.83 square kilometers of the total area of Selangor state are the extreme potential for fire. Extreme potential areas identified are in Bestari Jaya and Kuala Langat High Ulu. Continuity of information and terrestrial forest fire potential was displayed in WebGIS applications on the internet. Display information through WebGIS applications is a better approach to help the decision-making process at a high level of confidence and approximate real conditions. Agencies involved in disaster management such as Jawatankuasa Pengurusan Dan Bantuan Bencana (JPBB) of District, State and the National under the National Security Division and the Fire and Rescue Department Malaysia can use the end result of this study in preparation for the land and forest fires in the future.

  13. Utilizing Remote Sensing Information to Improve Post-fire Rainfall-runoff Predictions after the 2010 Bull Fire in the Sequoia National Forest, CA

    NASA Astrophysics Data System (ADS)

    Kinoshita, A. M.; Hale, B.; Hogue, T. S.

    2012-12-01

    Post-fire management decisions are guided by rainfall-runoff predictions, which ultimately influence downstream treatment and mitigation costs. The current study investigates evolving rainfall-runoff partitioning at the watershed scale over a two-year period after the 2010 Bull Fire which occurred in the southern Sequoia National Forest in California. Stage height was measured at five-minute intervals using pressure transducers, tipping buckets were installed for rainfall duration and intensity, and channel cross-sections were measured approximately every two months to detail sediment deposition or scour. We also utilize remotely sensed vegetation data to evaluate vegetation recovery in the studied watersheds and the corresponding relationship to storm runoff. Normalized Difference Vegetation Index (NDVI), a measure of vegetation greenness, is evaluated for its potential use as a key recovery indicator. Preliminary results focus on alterations in annual and seasonal precipitation and discharge relationships using in-situ data and Landsat NDVI values for the period of study. NDVI values are consistent with a comprehensive burn, with an acute decrease observed in the initial post-fire period. However, vegetation recovery is highly variable in the studied systems and influenced by shorter-term biomass pulses (grasses) while longer-term recovery of other species (chaparral and pine) is ongoing. Runoff ratios are elevated during early storms and show some recovery in the later part of the study period. The ability to accurately and confidently predict post-fire runoff and longer-term recovery is critical for monitoring values-at-risk, reducing mitigation costs, and improving warnings to downstream public communities.

  14. From Data to Knowledge — Faster: GOES Early Fire Detection System to Inform Operational Wildfire Response and Management

    NASA Astrophysics Data System (ADS)

    Koltunov, A.; Quayle, B.; Prins, E. M.; Ambrosia, V. G.; Ustin, S.

    2014-12-01

    Fire managers at various levels require near-real-time, low-cost, systematic, and reliable early detection capabilities with minimal latency to effectively respond to wildfire ignitions and minimize the risk of catastrophic development. The GOES satellite images collected for vast territories at high temporal frequencies provide a consistent and reliable source for operational active fire mapping realized by the WF-ABBA algorithm. However, their potential to provide early warning or rapid confirmation of initial fire ignition reports from conventional sources remains underutilized, partly because the operational wildfire detection has been successfully optimized for users and applications for which timeliness of initial detection is a low priority, contrasting to the needs of first responders. We present our progress in developing the GOES Early Fire Detection (GOES-EFD) system, a collaborative effort led by University of California-Davis and USDA Forest Service. The GOES-EFD specifically focuses on first detection timeliness for wildfire incidents. It is automatically trained for a monitored scene and capitalizes on multiyear cross-disciplinary algorithm research. Initial retrospective tests in Western US demonstrate significantly earlier identification detection of new ignitions than existing operational capabilities and a further improvement prospect. The GOES-EFD-β prototype will be initially deployed for the Western US region to process imagery from GOES-NOP and the rapid and 4 times higher spatial resolution imagery from GOES-R — the upcoming next generation of GOES satellites. These and other enhanced capabilities of GOES-R are expected to significantly improve the timeliness of fire ignition information from GOES-EFD.

  15. Cryptic chemical identification as a crime intelligence aid.

    PubMed

    Sturaro, A; Rella, R; Parvoli, G; Doretti, L

    1999-01-01

    A dead body was found near the sea and a commercial port in north-east Italy. The man had been shot and then burnt, by using a large volume of fire accelerant. The chemical composition of the flammable mixture had to be determined in order to aid police investigations. GC-MS analysis of residual cloth and soil identified a common gasoline, together with some unrelated compounds deriving from the container used to carry the inflammable liquid. A reconstruction of the event, an examination of the surroundings where the crime took place and the cryptic chemicals found, enabled the investigators to restrict and intensify their enquiries within a specific area.

  16. Lubricant Coating Process

    NASA Technical Reports Server (NTRS)

    1989-01-01

    "Peen Plating," a NASA developed process for applying molybdenum disulfide, is the key element of Techniblast Co.'s SURFGUARD process for applying high strength solid lubricants. The process requires two machines -- one for cleaning and one for coating. The cleaning step allows the coating to be bonded directly to the substrate to provide a better "anchor." The coating machine applies a half a micron thick coating. Then, a blast gun, using various pressures to vary peening intensities for different applications, fires high velocity "media" -- peening hammers -- ranging from plastic pellets to steel shot. Techniblast was assisted by Rural Enterprises, Inc. Coating service can be performed at either Techniblast's or a customer's facility.

  17. Management challenges in a short-range low-velocity gunshot injury.

    PubMed

    Arunkumar, K V; Kumar, Sanjeev; Aggarwal, Rajat; Dubey, Prajesh

    2012-07-01

    The use of firearms is becoming more prevalent in the society and hence the number of homicidal and suicidal cases. The severity of gunshot wounds varies depending on the weapons caliber and the distance of firing. Close-range, high-velocity gunshot wounds in the head and neck region can result in devastating esthetic and functional impairment. The complexity in facial skeletal anatomy cause multiple medical and surgical challenges to an operating surgeon, demanding elaborate soft and hard tissue reconstructions. Here we present the successful management of a patient shot by a low-velocity short-range pistol with basic life support measures, wound management, reconstruction, and rehabilitation.

  18. Improvement of ecological characteristics of the hydrogen diesel engine

    NASA Astrophysics Data System (ADS)

    Natriashvili, T.; Kavtaradze, R.; Glonti, M.

    2018-02-01

    In the article are considered the questions of influence of a swirl intensity of the shot and injector design on the ecological indices of the hydrogen diesel, little-investigated till now. The necessity of solution of these problems arises at conversion of the serial diesel engine into the hydrogen diesel. The mathematical model consists of the three-dimensional non-stationary equations of transfer and also models of turbulence and combustion. The numerical experiments have been carried out with the use of program code FIRE. The optimal values of parameters of the working process, ensuring improvement of the effective and ecological indices of the hydrogen diesel are determined.

  19. Bottlenecks in Geospatial Data-Driven Decision-Making for Natural Disaster Management: A Case Study of Forest Fire Prevention and Control in Guatemala's Maya Biosphere Reserve

    NASA Astrophysics Data System (ADS)

    Berenter, J. S.; Mueller, J. M.; Morrison, I.

    2016-12-01

    Annual forest fires are a source of great economic and environmental cost in the Maya Biosphere Reserve (MBR), a region of high ecological and historical value in Guatemala's department of Petén. Scarce institutional resources, limited local response capacity, and difficult terrain place a premium on the use of Earth observation data for forest fire management in the MBR, but also present significant institutional barriers to optimizing the value of this data. Drawing upon key informant interviews and a contingent valuation survey of national and local actors conducted during a three-year performance evaluation of the USAID/NASA Regional Visualization and Monitoring System (SERVIR), this paper traces the flow of SERVIR data from acquisition to decision in order to assess the institutional and contextual factors affecting the value of Earth observation data for forest fire management in the MBR. Findings indicate that the use of satellite data for forest fire management in the MBR is widespread and multi-dimensional: historical assessments of land use and land cover, fire scarring, and climate data help central-level fire management agencies identify and regulate fire-sensitive areas; regular monitoring and dissemination of climate data enables coordination between agricultural burning activities and fire early warning systems; and daily satellite detection of thermal anomalies in land surface temperature permits first responders to monitor and react to "hotspot" activity. Findings also suggest, however, that while the decentralized operations of Petén's fire management systems foster the use of Earth observation data, systemic bottlenecks, including budgetary constraints, inadequate data infrastructure and interpretation capacity, and obstacles to regulatory enforcement, impede the flow of information and use of technology and thus impact the value of that data, particularly in remote and under-resourced areas of the MBR. A geographic expansion and fortification of support systems for use of Earth observation data is thus required to maximize the value of data-driven forest fire management in the MBR. Findings further validate a need for continued cooperation between scientific and governance institutions to disseminate and integrate geospatial data into environmental decision-making.

  20. Trial by Fire

    NASA Technical Reports Server (NTRS)

    Covault, Craig

    2005-01-01

    Boeing is preparing a range of Delta IV Heavy launcher options for NASA Crew Exploration Vehicle (CEV) and unmanned cargo transportation architectures to the Moon and Mars, now that the massive new rocket has been flight tested. The December 21 launch of the 232-ft. vehicle on 2 million lb. thrust marked the largest all-liquid expendable booster flown since the last Saturn V in 1973. A second Delta IV Heavy mission is scheduled for this summer carrying a U.S. Air Force missile warning satellite. The first launch carried a dummy payload. Boeing wants NASA to consider the Delta IV Heavy for manned CEV missions, but is also pushing the Heavy for unmanned exploration launch roles. One Delta IV Medium version could also be a CEV player. Boeing says even modest upgrades could double the Delta Heavy's Earth orbit capability to more than 50 metric tons, including being able to fire up to 20 metric tons on escape trajectories to Mars.

  1. Methods for the Emergency Assessment of Debris-Flow Hazards from Basins Burned by the Fires of 2007, Southern California

    USGS Publications Warehouse

    Cannon, Susan H.; Gartner, Joseph E.; Michael, John A.

    2007-01-01

    This report describes the approach used to assess potential debris-flow hazards from basins burned by the Buckweed, Santiago, Canyon, Poomacha, Ranch, Harris, Witch, Rice, Ammo, Slide, Grass Valley and Cajon Fires of 2007 in southern California. The assessments will be presented as a series of maps showing a relative ranking of the predicted volume of debris flows that can issue from basin outlets in response to a 3-hour duration rainstorm with a 10-year return period. Potential volumes of debris flows are calculated using a multiple-regression model that describes debris-flow volume at a basin outlet as a function of measures of basin gradient, burn extent, and storm rainfall. This assessment provides critical information for issuing basin-specific warnings, locating and designing mitigation measures, and planning of evacuation timing and routes.

  2. Color associations among designers and non-designers for common warning and operation concepts.

    PubMed

    Ng, Annie W Y; Chan, Alan H S

    2018-07-01

    This study examined color-concept associations among designers and non-designers with commonly used warning and operation concepts. This study required 199 designers and 175 non-designers to indicate their choice among nine colors to associate with each of the 38 concepts in a color-concept table. The results showed that the designers and non-designers had the same color associations and similar strengths of stereotypes for 17 concepts. The strongest color-concept stereotypes for both groups were red-danger, red-fire, and red-hot. However, the designers and non-designers had different color associations for the concepts of escape (green, red), increase (green, red), potential hazard (red, orange), fatal (black, red), and normal (white, green), while the strengths of the 16 remaining associations for both groups were not at equivalent levels. These findings provide ergonomists and design practitioners with a better understanding of population stereotypes for color coding, and consequently to effectively use colors in their user-centered designs. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. APDS: Autonomous Pathogen Detection System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Langlois, R G; Brown, S; Burris, L

    An early warning system to counter bioterrorism, the Autonomous Pathogen Detection System (APDS) continuously monitors the environment for the presence of biological pathogens (e.g., anthrax) and once detected, it sounds an alarm much like a smoke detector warns of a fire. Long before September 11, 2001, this system was being developed to protect domestic venues and events including performing arts centers, mass transit systems, major sporting and entertainment events, and other high profile situations in which the public is at risk of becoming a target of bioterrorist attacks. Customizing off-the-shelf components and developing new components, a multidisciplinary team developed APDS,more » a stand-alone system for rapid, continuous monitoring of multiple airborne biological threat agents in the environment. The completely automated APDS samples the air, prepares fluid samples in-line, and performs two orthogonal tests: immunoassay and nucleic acid detection. When compared to competing technologies, APDS is unprecedented in terms of flexibility and system performance.« less

  4. Early warning, warning or alarm systems for natural hazards? A generic classification.

    NASA Astrophysics Data System (ADS)

    Sättele, Martina; Bründl, Michael; Straub, Daniel

    2013-04-01

    Early warning, warning and alarm systems have gained popularity in recent years as cost-efficient measures for dangerous natural hazard processes such as floods, storms, rock and snow avalanches, debris flows, rock and ice falls, landslides, flash floods, glacier lake outburst floods, forest fires and even earthquakes. These systems can generate information before an event causes loss of property and life. In this way, they mainly mitigate the overall risk by reducing the presence probability of endangered objects. These systems are typically prototypes tailored to specific project needs. Despite their importance there is no recognised system classification. This contribution classifies warning and alarm systems into three classes: i) threshold systems, ii) expert systems and iii) model-based expert systems. The result is a generic classification, which takes the characteristics of the natural hazard process itself and the related monitoring possibilities into account. The choice of the monitoring parameters directly determines the system's lead time. The classification of 52 active systems moreover revealed typical system characteristics for each system class. i) Threshold systems monitor dynamic process parameters of ongoing events (e.g. water level of a debris flow) and incorporate minor lead times. They have a local geographical coverage and a predefined threshold determines if an alarm is automatically activated to warn endangered objects, authorities and system operators. ii) Expert systems monitor direct changes in the variable disposition (e.g crack opening before a rock avalanche) or trigger events (e.g. heavy rain) at a local scale before the main event starts and thus offer extended lead times. The final alarm decision incorporates human, model and organisational related factors. iii) Model-based expert systems monitor indirect changes in the variable disposition (e.g. snow temperature, height or solar radiation that influence the occurrence probability of snow avalanches) or trigger events (e.g. heavy snow fall) to predict spontaneous hazard events in advance. They encompass regional or national measuring networks and satisfy additional demands such as the standardisation of the measuring stations. The developed classification and the characteristics, which were revealed for each class, yield a valuable input to quantifying the reliability of warning and alarm systems. Importantly, this will facilitate to compare them with well-established standard mitigation measures such as dams, nets and galleries within an integrated risk management approach.

  5. A framework for tracking post-wildfire trajectories and desired future conditions using NDVI time series

    NASA Astrophysics Data System (ADS)

    Norman, S. P.; Hargrove, W. W.; Lee, D. C.; Spruce, J.

    2013-12-01

    Wildfires could provide a cost-effective means to maintain or restore some aspects of fire-adapted landscapes. Yet with the added influence of climate change and invasives, wildfires may also facilitate or accelerate undesired type conversions. As megafires are becoming increasingly common across portions of the US West, managers require a framework for long-term monitoring that integrates the trajectories of fire-prone landscapes and objectives, not just conditions immediately after a burn. Systematic use of satellite data provides an efficient cross-jurisdictional solution to this problem. Since 2000, MODIS-technology has provided high frequency, 240m resolution observations of Earth. Using this data stream, the ForWarn system, developed through a partnership of the US Forest Service, NASA-Stennis and others, provides 46 estimates of the Normalized Difference Vegetation Index (NDVI) per year for the conterminous US. From this time series, a variety of secondary metrics have been derived including median annual NDVI, amplitude, and phenological spikiness. Each is both a fire and recovery sensitive measure that allows managers to systematically track conditions with respect to either the pre-fire baseline or desired future conditions more adaptively. In dry interior forests where wildfires could be used to thin stands, recovery to untreated conditions may not be desired given fuels objectives or climate change. In more mesic systems, fire effects may be monitored as staged succession. With both coarse filter monitoring and desired conditions in hand, managers can better recognize and prioritize problems in disturbance-prone landscapes.

  6. Soft soap as a tissue simulant medium for wound ballistic studies investigated by comparative firings with assault rifles Ak 4 and M16A1 into live, anesthetized animals.

    PubMed

    Janzon, B

    1982-01-01

    For the purpose of comparing the properties of a particular soft soap with those of live muscle tissue, a comparative study was carried out, involving firings into live, anesthetized pigs and into blocks of soft soap. The weapon - ammunition combinations utilized were Ak 4 - sk ptr 10 prj - the Swedish version of 7.62 mm NATO assault rifle M16A1- M. 193 - the U.S. standard weapon, calibre 5.56 mm. The registrations were done by flash X-ray units of 105 and 150 kilovolts, mounted in an orthogonal stereo set-up with 8-11 units, making it possible to obtain 4 to 6 measurements of bullet position, yaw angle etc. during the penetration of the target in one shot. By evaluation of these firings, and by "pooling" of the data for each series it was possible to calculate retardation force on the bullet as a function of penetration depth for the soap targets, and for the live targets. The results show that no significant difference can be discerned between the soft soap and animal tissue as regards their influence on the behaviour of the bullet.

  7. Proceedings of a Hydrology and Hydraulics Workshop (23rd) on Hydrologic Studies in Support of Project Functions Held in Angel Fire, New Mexico on 7-9 August 1990

    DTIC Science & Technology

    1990-01-01

    Pecos River Watershed. Refer to the vicinity map on Plate 1. The source of the Pecos River basin is in the Sangre de Cristo Mountains about 395 miles...resulted in a favorable court decision for the Corps and never actually impacted hydropower or the quantity of water supply storage reallocated...sensing gage. The stage warning gage consists of a telephone alarm dialer mounted in a shelter atop a stilling well which contains float switches

  8. Secondary skull fractures in head wounds inflicted by captive bolt guns: autopsy findings and experimental simulation.

    PubMed

    Perdekamp, Markus Grosse; Kneubuehl, Beat P; Ishikawa, Takaki; Nadjem, Hadi; Kromeier, Jan; Pollak, Stefan; Thierauf, Annette

    2010-11-01

    Apart from one article published by Rabl and Sigrist in 1992 (Rechtsmedizin 2:156-158), there are no further reports on secondary skull fractures in shots from captive bolt guns. Up to now, the pertinent literature places particular emphasis on the absence of indirect lesions away from the impact point, when dealing with the wounding capacity of slaughterer's guns. The recent observation of two suicidal head injuries accompanied by skull fractures far away from the bolt's path gave occasion to experimental studies using simulants (glycerin soap, balls from gelatin) and skull–brain models. As far as ballistic soap was concerned, the dimensions of the bolt's channel were assessed by multi-slice computed tomography before cutting the blocks open. The test shots to gelatin balls and to skull-brain models were documented by means of a high-speed motion camera. As expected, the typical temporary cavity effect of bullets fired from conventional guns could not be observed when captive bolt stunners were discharged. Nevertheless, the visualized transfer of kinetic energy justifies the assumption that the secondary fractures seen in thin parts of the skull were caused by a hydraulic burst effect.

  9. Gunshot residue patterns on skin in angled contact and near contact gunshot wounds.

    PubMed

    Plattner, T; Kneubuehl, B; Thali, M; Zollinger, U

    2003-12-17

    The goal of this study was the reproduction of shape and pattern of gunshot residues in near contact and contact gunshot wounds by a series of experimental gunshots on a skin and soft tissue model. The aim was to investigate the shape and direction of soot deposits with regard to the muzzle according to different muzzle-target angles, firing distances, type of ammunition and weapon and barrel length. Based on a review of the literature and on the results of the experiments the authors could make the following statements of gunshot residues in angled contact and close contact gunshot: (1) gunshot residues on the target surface can be differentiated in a "inner" and "outer powder soot zone"; (2) the outer powder soot zone is much less visible than the inner powder soot zone and may lack on human skin; (3) with increasing muzzle target distance both inner and outer powder soot halo increase in size and decrease in density; (4) in angled shots the inner powder soot halo shows an eccentric, elliptic shape which points towards the muzzle, regardless of ammunition, calibre and barrel length; (5) the outer powder soot points away from the muzzle in angled contact and close contact shots.

  10. Ground Truth Collections for Explosions in Northern Fennoscandia and Russia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harris, D B; Ringdal, F; Kremenetskaya, E

    2003-07-28

    This project is providing ground-truth information on explosions conducted at the principal mines within 500 kilometers of the ARCES station, and is assembling a seismic waveform database for these events from local and regional stations. The principal mines of interest are in northwest Russia (Khibiny Massif, Olenogorsk, Zapolyamy, and Kovdor groups) and Sweden (Malmberget, Kiruna). These mines form a natural laboratory for examining the variation of mining explosion observations with source type, since they include colocated surface and underground mines and mines conducting a variety of different shot types. In September 2002 we deployed two lines of temporary stations frommore » the Khibiny Massif through and to the north of the ARCES station. This deployment is producing data that will allow researchers to examine the variation of discriminants caused by varying source-receiver distance and the diversity of explosion types. To date, we have collected ground-truth information on 1,118 explosions in the Kola Peninsula, and have assembled waveform data for approximately 700 of these. The database includes waveforms from instruments temporarily deployed in the Khibiny Massif mines, from the Apatity network just outside of the Massif, from LVZ, KEV and ARCES, and from the stations deployed along the two lines into northern Norway. In this paper we present representative waveforms for several types of shots recorded at various regional distances. We have conducted a preliminary study of the variation of phase ratios as a function of source type. This study shows significant differences in Pd/Sn and Pd/Lg ratios for two types of mining explosions: surface ripple-fired explosions and compact underground explosions. Compact explosions are, typically, underground explosions of a few tons with only one or two short delays, and are the closest approximation to single, well-tamped explosions available in the Khibiny mines. The surface shots typically are much larger (ranging up to hundreds of tons), with many delays. The surface mine that we present results for typically also conducts several distinct shots across the mine nearly simultaneously (with a few seconds or tens of seconds). Measured phase ratios are more consistent for compact underground explosions. This consistency is an expected result given the smaller scope for shot variation in these smaller events. In addition, Pd/Lg ratios appear more stable than Pd/Sn ratios for both types of events. The most interesting result is that the compact underground explosions are richer in shear energy (i.e. having smaller P/S ratios) than their surface ripple-fired counterparts. We continue to work on an approach for identifying the principal mines to be targeted for screening at a particular station. Often, routine industrial blasts constitute a large proportion of events detected by monitoring stations close to major mining districts. Many mines may be present, and it may be a problem to determine which subset of mines is responsible for the majority of the events, and should be prime candidates for the deployment of ground-truth collection resources. Our solution to this problem entails several steps. The first is to find geographic clusters of events that may correspond to major groups of mines. For this step, we use event density maps generated from existing network catalogs. This year we examined some of the tradeoffs in generating event density maps: use of automated bulletins to produce maps vs. analyst-reviewed bulletins, and the amount of time required to produce stables maps which can be used to identify significant mines.« less

  11. Saudi Arabian seismic deep-refraction profiles; final project report

    USGS Publications Warehouse

    Healy, J.H.; Mooney, W.D.; Blank, H.R.; Gettings, M.E.; Kohler, W.M.; Lamson, R.J.; Leone, L.E.

    1983-01-01

    In February 1978 a seismic deep-refraction profile was recorded by the U.S. Geological Survey along a 1000-km line across the Arabian Shield in western Saudi Arabia. The line begins in Mesozoic cover rocks near Riyadh on the Arabian Platform, leads southwesterly across three major Precambrian tectonic provinces, traverses Cenozoic rocks of the coastal plain near Jizan (Tihamat-Asir), and terminates at the outer edge of the Farasan Bank in the southern Red Sea. More than 500 surveyed recording sites were occupied, including 19 in the Farasan Islands. Six shot points were used: five on land, with most charges placed below the water table in drill holes, and one at sea, with charges placed on the sea floor and detonated from a ship. Slightly more than 61 metric tons of explosives were used in 19 discrete firings. Seismic energy was recorded by 100 newly-developed portable seismic stations deployed in approximately 200 km-long arrays for each firing. Each station consisted of a standard 2-Hz vertical component geophone coupled to a self-contained analog recording instrument equipped with a magnetic-tape cassette. In this final report, we fully document the field and data-processing procedures and present the final seismogram data set as both a digital magnetic tape and as record sections for each shot point. Record sections include a normalized set of seismograms, reduced at 6 km/s, and a true-amplitude set, reduced at 8 km/s, which have been adjusted for amplifier gain, individual shot size, and distance from the shot point. Appendices give recorder station and shot information, digital data set descriptions, computer program listings, arrival times used in the interpretation, and a bibliography of reports published as a result of this project. We used two-dimensional ray-tracing techniques in the data analysis, and our interpretation is based primarily on horizontally layered models. The Arabian Shield is composed, to first-order, of two layers, each about 20 km thick, with average velocities of 6.3 km/s and 7.0 km/s, respectively. At the western shield margin the crust thins to less than 20 km total thickness, beyond which the Red Sea shelf and coastal plain are interpreted to be underlain by oceanic crust. A major crustal lateral velocity inhomogeneity northeast of Sabhah in the Shammar Tectonic Province is interpreted as the suture zone of two crustal blocks of different composition. Several high-velocity anomalies in the upper crust correlate with mapped gneissic dome structures. Two intra-crustal reflectors at13 km depth are interpreted as the tops of mafic intrusives. The Mohorovicic discontinuity beneath the shield varies from 43 km depth in the northeast with 8.2 km/s mantle velocity to 38 km depth in the southwest with 8.0 km/s mantle velocity. Two velocity discontinuities are identified in the upper mantle, at 59 and 70 km depth. We suggest further work, including refined analyses of the data employing filtering and synthetic seismogram techniques, as well as consideration of attenuation properties. Extension of the seismic refraction profile to the Arabian Gulf and some short profiles perpendicular to the existing profile would be fruitful areas for future field work.

  12. A robust scientific workflow for assessing fire danger levels using open-source software

    NASA Astrophysics Data System (ADS)

    Vitolo, Claudia; Di Giuseppe, Francesca; Smith, Paul

    2017-04-01

    Modelling forest fires is theoretically and computationally challenging because it involves the use of a wide variety of information, in large volumes and affected by high uncertainties. In-situ observations of wildfire, for instance, are highly sparse and need to be complemented by remotely sensed data measuring biomass burning to achieve homogeneous coverage at global scale. Fire models use weather reanalysis products to measure energy release and rate of spread but can only assess the potential predictability of fire danger as the actual ignition is due to human behaviour and, therefore, very unpredictable. Lastly, fire forecasting systems rely on weather forecasts to extend the advance warning but are currently calibrated using fire danger thresholds that are defined at global scale and do not take into account the spatial variability of fuel availability. As a consequence, uncertainties sharply increase cascading from the observational to the modelling stage and they might be further inflated by non-reproducible analyses. Although uncertainties in observations will only decrease with technological advances over the next decades, the other uncertainties (i.e. generated during modelling and post-processing) can already be addressed by developing transparent and reproducible analysis workflows, even more if implemented within open-source initiatives. This is because reproducible workflows aim to streamline the processing task as they present ready-made solutions to handle and manipulate complex and heterogeneous datasets. Also, opening the code to the scrutiny of other experts increases the chances to implement more robust solutions and avoids duplication of efforts. In this work we present our contribution to the forest fire modelling community: an open-source tool called "caliver" for the calibration and verification of forest fire model results. This tool is developed in the R programming language and publicly available under an open license. We will present the caliver R package, illustrate the main functionalities and show the results of our preliminary experiments calculating fire danger thresholds for various regions on Earth. We will compare these with the existing global thresholds and, lastly, demonstrate how these newly-calculated regional thresholds can lead to improved calibration of fire forecast models in an operational setting.

  13. Benefits of Earthquake Early Warning to Large Municipalities (Invited)

    NASA Astrophysics Data System (ADS)

    Featherstone, J.

    2013-12-01

    The City of Los Angeles has been involved in the testing of the Cal Tech Shake Alert, Earthquake Early Warning (EQEW) system, since February 2012. This system accesses a network of seismic monitors installed throughout California. The system analyzes and processes seismic information, and transmits a warning (audible and visual) when an earthquake occurs. In late 2011, the City of Los Angeles Emergency Management Department (EMD) was approached by Cal Tech regarding EQEW, and immediately recognized the value of the system. Simultaneously, EMD was in the process of finalizing a report by a multi-discipline team that visited Japan in December 2011, which spoke to the effectiveness of EQEW for the March 11, 2011 earthquake that struck that country. Information collected by the team confirmed that the EQEW systems proved to be very effective in alerting the population of the impending earthquake. The EQEW in Japan is also tied to mechanical safeguards, such as the stopping of high-speed trains. For a city the size and complexity of Los Angeles, the implementation of a reliable EQEW system will save lives, reduce loss, ensure effective and rapid emergency response, and will greatly enhance the ability of the region to recovery from a damaging earthquake. The current Shake Alert system is being tested at several governmental organizations and private businesses in the region. EMD, in cooperation with Cal Tech, identified several locations internal to the City where the system would have an immediate benefit. These include the staff offices within EMD, the Los Angeles Police Department's Real Time Analysis and Critical Response Division (24 hour crime center), and the Los Angeles Fire Department's Metropolitan Fire Communications (911 Dispatch). All three of these agencies routinely manage the collaboration and coordination of citywide emergency information and response during times of crisis. Having these three key public safety offices connected and included in the early testing of an EQEW system will help shape the EQEW policy which will determine the seismic safety of millions of Californians in the years to come.

  14. Monitoring Regional Forest Disturbances across the US with Near Real Time MODIS NDVI Products included in the ForWarn Forest Threat Early Warning System

    NASA Astrophysics Data System (ADS)

    Spruce, J.; Hargrove, W. W.; Gasser, J.; Norman, S. P.

    2013-12-01

    Forest threats across the US have become increasingly evident in recent years. These include regionally extensive disturbances (e.g., from drought, bark beetle outbreaks, and wildfires) that can occur across multiyear durations and result in extensive forest mortality. In addition, forests can be subject to ephemeral, sometimes yearly defoliation from various insects and types of storm damage. After prolonged severe disturbance, signs of forest recovery can vary in terms of satellite-based Normalized Difference Vegetation Index (NDVI) values. The increased extent and threat of forest disturbances in part led to the enactment of the 2003 Healthy Forest Restoration Act, which mandated that a national forest threat Early Warning System (EWS) be deployed. In response, the US Forest Service collaborated with NASA, DOE Oak Ridge National Laboratory, and the USGS Eros Data Center to build the near real time ForWarn forest threat EWS for monitoring regionally evident forest disturbances, starting on-line operations in 2010. Given the diversity of disturbance types, severities, and durations, ForWarn employs multiple historical baselines used with current NDVI to derive a suite of six nationwide 'weekly' forest change products. ForWarn uses daily 232 meter MODIS Aqua and Terra satellite NDVI data, including MOD13 products for deriving historical baseline NDVIs and eMODIS products for compiling current NDVI. Separately pre-processing the current and historical NDVIs, the Time Series Product Tool and the Phenological Parameters Estimation Tool are used to temporally reduce noise, fuse, and aggregate MODIS NDVIs into 24 day composites refreshed every 8 days with 46 dates of forest change products per year. The 24 day compositing interval typically enables new disturbances to be detected, while minimizing the frequency of residual atmospheric contamination. ForWarn's three standard forest change products compare current NDVI to that from the previous year, previous 3 years, and all previous years since 2000. Other forest change products added in 2013 include one for quicker disturbance detection and two others that adjust for seasonal fluctuations in normal vegetation phenology. This product suite and ForWarn's geospatial data viewer allow end users to view and assess disturbance dynamics for many regionally evident biotic and abiotic forest disturbances throughout a given current year. ForWarn's change products are also being used for forest change trend analysis and for developing regional forest overstory mortality products. They are used to alert forest health specialists about new regional forest disturbances. Such alerts also typically consider available Landsat, aerial, and ground data as well as communications with forest health specialists and previous experience. ForWarn products have been used to detect and track many types of regional disturbances for multiple forest types, including defoliation from caterpillars and severe storms, as well as mortality from both biotic and abiotic agents (e.g., bark beetles, drought, fire, anthropogenic clearing). ForWarn provides forest change products that could be combined with other geospatial data on forest biomass to help assess forest disturbance carbon impacts within the conterminous US.

  15. 2015 Indonesian fire activity and smoke pollution show persistent non-linear sensitivity to El Niño-induced drought

    NASA Astrophysics Data System (ADS)

    Field, R. D.; van der Werf, G.; Fanin, T.; Fetzer, E. J.; Fuller, R. A.; Jethva, H. T.; Levy, R. C.; Livesey, N. J.; Luo, M.; Torres, O.; Worden, H. M.

    2016-12-01

    The 2015 fire season and related smoke pollution in Indonesia was more severe than the major 2006 episode, making it the most severe season observed by the NASA Earth Observing System satellites that go back to the early 2000s, namely active fire detections from the Terra and Aqua Moderate Resolution Imaging Spectroradiometers (MODIS), MODIS aerosol optical depth, Terra Measurement of Pollution in the Troposphere (MOPITT) carbon monoxide (CO), Aqua Atmospheric Infrared Sounder (AIRS) CO, Aura Ozone Monitoring Instrument (OMI) aerosol index, and Aura Microwave Limb Sounder (MLS) CO. The MLS CO in the upper troposphere showed a plume of pollution stretching from East Africa to the western Pacific Ocean that persisted for two months. Longer-term records of airport visibility in Sumatra and Kalimantan show that 2015 ranked after 1997 and alongside 1991 and 1994 as among the worst episodes on record. Analysis of yearly dry season rainfall from the Tropical Rainfall Measurement Mission (TRMM) and rain gauges shows that, due to the continued use of fire to clear and prepare land on degraded peat, the Indonesian fire environment continues to have non-linear sensitivity to dry conditions during prolonged periods with less than 4mm/day of precipitation, and this sensitivity appears to have increased over Kalimantan. Without significant reforms in land use and the adoption of early warning triggers tied to precipitation forecasts, these intense fire episodes will re-occur during future droughts, usually associated with El Niño events. Characterization of this signifcant event was only possible with EOS data, from the A-train instruments especially.

  16. Bastrop County Complex Fire Burn Scar

    NASA Image and Video Library

    2017-12-08

    NASA image acquired September 12, 2011 To view more images from this event go to: earthobservatory.nasa.gov/NaturalHazards/event.php?id=52029 The Bastrop County Complex Fire in southern Texas started on September 4, 2011. By September 13, 2011, the fire was 70 percent contained, but had scorched 34,068 acres (13,787 hectares). The Advanced Land Imager (ALI) on NASA’s Earth Observing-1 (EO-1) satellite captured this image of the affected region on September 12, 2011. This false-color image shows a wide-area view of the fire. Vegetation is bright green, and sparsely vegetated or bare land is green-yellow. The burn scar appears in shades of red and orange. The burn scar is far from uniform; burned areas are separated by unburned expanses. As of September 13, a re-entry plan had been established for residents of the region, the Incident Information System reported. Residents were warned, however, that they might see vegetation still smoldering or burning. Ongoing drought set the stage for severe fires in Texas in the slate summer of 2011. In early September, Tropical Storm Lee, which drenched other parts of the United States, brought strong winds to Texas, worsening the fires. NASA Earth Observatory image created by Jesse Allen and Robert Simmon, using EO-1 ALI data provided courtesy of the NASA EO-1 team. Caption by Michon Scott. Instrument: EO-1 - ALI Credit: NASA Earth Observatory NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  17. Nowcasting of Lightning-Related Accidents in Africa

    NASA Astrophysics Data System (ADS)

    Ihrlich, Laura; Price, Colin

    2016-04-01

    Tropical Africa is the world capital of thunderstorm activity with the highest density of strikes per square kilometer per year. As a result it is also the continent with perhaps the highest casualties and injuries from direct lightning strikes. This region of the globe also has little lightning protection of rural homes and schools, while many casualties occur during outdoor activities (e.g. farming, fishing, sports, etc.) In this study we investigated two lightning-caused accidents that got wide press coverage: A lightning strike to a Cheetah Center in Namibia which caused a huge fire and great destruction (16 October 2013), and a plane crash in Mali where 116 people died (24 July 2014). Using data from the World Wide Lightning Location Network (WWLLN) we show that the lightning data alone can provide important early warning information that can be used to reduce risks and damages and loss of life from lightning strikes. We have developed a now-casting scheme that allows for early warnings across Africa with a relatively low false alarm rate. To verify the accuracy of our now-cast, we have performed some statistical analysis showing relatively high skill at providing early warnings (lead time of a few hours) based on lightning alone. Furthermore, our analysis can be used in forensic meteorology for determining if such accidents are caused by lightning strikes.

  18. Emergency assessment of post-fire debris-flow hazards for the 2013 Mountain fire, southern California

    USGS Publications Warehouse

    Staley, Dennis M.; Gartner, Joseph E.; Smoczyk, Greg M.; Reeves, Ryan R.

    2013-01-01

    Wildfire dramatically alters the hydrologic response of a watershed such that even modest rainstorms can produce dangerous flash floods and debris flows. We use empirical models to predict the probability and magnitude of debris flow occurrence in response to a 10-year rainstorm for the 2013 Mountain fire near Palm Springs, California. Overall, the models predict a relatively high probability (60–100 percent) of debris flow for six of the drainage basins in the burn area in response to a 10-year recurrence interval design storm. Volumetric predictions suggest that debris flows that occur may entrain a significant volume of material, with 8 of the 14 basins identified as having potential debris-flow volumes greater than 100,000 cubic meters. These results suggest there is a high likelihood of significant debris-flow hazard within and downstream of the burn area for nearby populations, infrastructure, and wildlife and water resources. Given these findings, we recommend that residents, emergency managers, and public works departments pay close attention to weather forecasts and National Weather Service–issued Debris Flow and Flash Flood Outlooks, Watches and Warnings and that residents adhere to any evacuation orders.

  19. Babies and shots

    MedlinePlus

    ... MMR - shots; Pneumococcal - shots; Polio - shots; IPV - shots; Rotavirus - shots; Tdap - shots ... conjugate vaccine Pneumococcal polysaccharide vaccine Polio immunization (vaccine) Rotavirus vaccine Tdap vaccine

  20. Pellet injection research on the HT-6M and HT-7 tokamaks

    NASA Astrophysics Data System (ADS)

    Yang, Yu; Bao, Yi; Li, Jiangang; Gu, Xuemao; He, Yexi

    1999-11-01

    A multishot in situ pellet injection system has been constructed in the Institute of Plasma Physics. Single- and multi-pellet injection experiments were performed on the HT-6M and superconducting HT-7 tokamaks. The system proved to be convenient and reliable to operate. Pellets were fired into ohmically and LHCD and ICRF heated plasmas. Single pellet injection in ohmic discharge was found to increase the central density of HT-7 by about one half, while two pellet injection increased the central density in a step-like fashion by one half with each shot. Peaking of the electron density profile and a hollow electron temperature profile were obtained.

  1. A bullet fired in dry water: an investigative activity to learn hydrodynamics concepts

    NASA Astrophysics Data System (ADS)

    Azevedo Leitão, Ulisses; dos Anjos Pinheiro da Silva, Antonio; Trindade do Nascimento, Natália Cristina; Mara Benedita da Cruz Gervásio, Lilian

    2017-01-01

    In this paper we report an investigative activity on hydrodynamics, in the context of an inquiry-based learning project. The aim is to analyse the experiment of a bullet shot underwater. Using Tracker, a video analysing and modelling software, the displacement of the bullet was measured as function of time, processing a slow motion video from YouTube. It was found that the displacement of the bullet is well described in the first 20 ms by the inviscid flow regime, where the Newtonian drag force overcomes the viscous drag. This behaviour is discussed in the context of what Richard Feynman’s famous Lectures on Physics describes as ‘The Flow of Dry Water’.

  2. Wound ballistic evaluation of the Taser® XREP ammunition.

    PubMed

    Kunz, Sebastian N; Adamec, Jiri; Zinka, Bettina; Münzel, Daniela; Noël, Peter B; Eichner, Simon; Manthei, Axel; Grove, Nico; Graw, M; Peschel, Oliver

    2013-01-01

    The Taser® eXtended Range Electronic Projectile (XREP®) is a wireless conducted electrical weapon (CEW) designed to incapacitate a person from a larger distance. The aim of this study was to analyze the ballistic injury potential of the XREP. Twenty rounds were fired from the Taser®X12 TM shotgun into ballistic soap covered with artificial skin and clothing at different shooting distances (1-25 m). One shot was fired at pig skin at a shooting distance of 10 m. The average projectile velocity was 67.0 m/s. The kinetic energy levels on impact varied from 28-52 J. Depending on the intermediate target, the projectiles penetrated up to 4.2 cm into the ballistic soap. On impact the nose assembly did not separate from the chassis, and no electrical activation was registered. Upon impact, a skin penetration of the XREP cannot be excluded. However, it is very unlikely at shooting distances of 10 m or more. Clothing and a high elasticity limit of the target body area can significantly reduce the penetration risk on impact.

  3. Operating Ferret on a patrol boat

    NASA Astrophysics Data System (ADS)

    Bédard, Jacques

    2006-05-01

    Ferret is an acoustic system that detects, recognizes and localizes the source and direction of small arms fire. The system comprises a small array of microphones and pressure sensors connected to a standard PC-104 computer that analyzes, displays, reports and logs the parameters of a recognized shot. The system operates by detecting and recognizing the ballistic shock waves created by the supersonic bullet, combined with the muzzle blast wave propagating from the weapon. The system was recently installed and tested on a patrol boat operated by the Royal Canadian Mounted Police (RCMP). An electronic compass with tilt compensation and a GPS was incorporated into the system. This allows the system to correct for the motion of the boat and provide the full coordinates of the shooter. The system also updates the azimuth to the shooter in real time as the boat turns. This paper presents the results of our test and evaluation based on a live firing experiment. Ferret is the result of a collaborative effort by Defence R&D Canada and MacDonald Dettwiler and Associates.

  4. In situ measurements of post-fire debris flows in southern California: Comparisons of the timing and magnitude of 24 debris-flow events with rainfall and soil moisture conditions

    USGS Publications Warehouse

    Kean, J.W.; Staley, D.M.; Cannon, S.H.

    2011-01-01

    Debris flows often occur in burned steeplands of southern California, sometimes causing property damage and loss of life. In an effort to better understand the hydrologic controls on post-fire debris-flow initiation, timing and magnitude, we measured the flow stage, rainfall, channel bed pore fluid pressure and hillslope soil-moisture accompanying 24 debris flows recorded in five different watersheds burned in the 2009 Station and Jesusita Fires (San Gabriel and Santa Ynez Mountains). The measurements show substantial differences in debris-flow dynamics between sites and between sequential events at the same site. Despite these differences, the timing and magnitude of all events were consistently associated with local peaks in short duration (< = 30 min) rainfall intensity. Overall, debris-flow stage was best cross-correlated with time series of 5-min rainfall intensity, and lagged the rainfall by an average of just 5 min. An index of debris-flow volume was also best correlated with short-duration rainfall intensity, but found to be poorly correlated with storm cumulative rainfall and hillslope soil water content. Post-event observations of erosion and slope stability modeling suggest that the debris flows initiated primarily by processes related to surface water runoff, rather than shallow landslides. By identifying the storm characteristics most closely associated with post-fire debris flows, these measurements provide valuable guidance for warning operations and important constraints for developing and testing models of post-fire debris flows. copyright. 2011 by the American Geophysical Union.

  5. Current scaling of radiated power for 40-mm diameter single wire arrays on Z

    NASA Astrophysics Data System (ADS)

    Nash, T. J.; Cuneo, M. E.; Spielman, R. B.; Chandler, G. A.; Leeper, R. J.; Seaman, J. F.; McGurn, J.; Lazier, S.; Torres, J.; Jobe, D.; Gilliland, T.; Nielsen, D.; Hawn, R.; Bailey, J. E.; Lake, P.; Carlson, A. L.; Seamen, H.; Moore, T.; Smelser, R.; Pyle, J.; Wagoner, T. C.; LePell, P. D.; Deeney, C.; Douglas, M. R.; McDaniel, D.; Struve, K.; Mazarakis, M.; Stygar, W. A.

    2004-11-01

    In order to estimate the radiated power that can be expected from the next-generation Z-pinch driver such as ZR at 28 MA, current-scaling experiments have been conducted on the 20 MA driver Z. We report on the current scaling of single 40 mm diameter tungsten 240 wire arrays with a fixed 110 ns implosion time. The wire diameter is decreased in proportion to the load current. Reducing the charge voltage on the Marx banks reduces the load current. On one shot, firing only three of the four levels of the Z machine further reduced the load current. The radiated energy scaled as the current squared as expected but the radiated power scaled as the current to the 3.52±0.42 power due to increased x-ray pulse width at lower current. As the current is reduced, the rise time of the x-ray pulse increases and at the lowest current value of 10.4 MA, a shoulder appears on the leading edge of the x-ray pulse. In order to determine the nature of the plasma producing the leading edge of the x-ray pulse at low currents further shots were taken with an on-axis aperture to view on-axis precursor plasma. This aperture appeared to perturb the pinch in a favorable manner such that with the aperture in place there was no leading edge to the x-ray pulses at lower currents and the radiated power scaled as the current squared ±0.75. For a full-current shot we will present x-ray images that show precursor plasma emitting on-axis 77 ns before the main x-ray burst.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kevin C. Galbreath; Donald L. Toman; Christopher J. Zygarlicke

    Petroleum coke, a byproduct of the petroleum-refining process, is an attractive primary or supplemental fuel for power production primarily because of a progressive and predictable increase in the production volumes of petroleum coke (1, 2). Petroleum coke is most commonly blended with coal in proportions suitable to meet sulfur emission compliance. Petroleum coke is generally less reactive than coal; therefore, the cofiring of petroleum coke with coal typically improves ignition, flame stability, and carbon loss relative to the combustion of petroleum coke alone. Although petroleum coke is a desirable fuel for producing relatively inexpensive electrical power, concerns about the effectsmore » of petroleum coke blending on combustion and pollution control processes exist in the coal-fired utility industry (3). The Energy & Environmental Research Center (EERC) completed a 2-year technical assessment of petroleum coke as a supplemental fuel. A survey questionnaire was sent to seven electric utility companies that are currently cofiring coal and petroleum coke in an effort to solicit specific suggestions on research needs and fuel selections. An example of the letter and survey questionnaire is presented in Appendix A. Interest was expressed by most utilities in evaluating the effects of petroleum coke blending on grindability, combustion reactivity, fouling, slagging, and fly ash emissions control. Unexpectedly, concern over corrosion was not expressed by the utilities contacted. Although all seven utilities responded to the question, only two utilities, Northern States Power Company (NSP) and Ameren, sent fuels to the EERC for evaluation. Both utilities sent subbituminous coals from the Power River Basin and petroleum shot coke samples. Petroleum shot coke is produced unintentionally during operational upsets in the petroleum refining process. This report evaluates the effects of petroleum shot coke blending on grindability, fuel reactivity, fouling/slagging, and electrostatic precipitator (ESP) fly ash collection efficiency.« less

  7. On the Path to SunShot. Advancing Concentrating Solar Power Technology, Performance, and Dispatchability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mehos, Mark; Turchi, Craig; Jorgenson, Jennie

    2016-05-01

    This report examines the remaining challenges to achieving the competitive concentrating solar power (CSP) costs and large-scale deployment envisioned under the U.S. Department of Energy's SunShot Initiative. Although CSP costs continue to decline toward SunShot targets, CSP acceptance and deployment have been hindered by inexpensive photovoltaics (PV). However, a recent analysis found that thermal energy storage (TES) could increase CSP's value--based on combined operational and capacity benefits--by up to 6 cents/kWh compared to variable-generation PV, under a 40% renewable portfolio standard in California. Thus, the high grid value of CSP-TES must be considered when evaluating renewable energy options. An assessmentmore » of net system cost accounts for the difference between the costs of adding new generation and the avoided cost from displacing other resources providing the same level of energy and reliability. The net system costs of several CSP configurations are compared with the net system costs of conventional natural-gas-fired combustion-turbine (CT) and combined-cycle plants. At today's low natural gas prices and carbon emission costs, the economics suggest a peaking configuration for CSP. However, with high natural gas prices and emission costs, each of the CSP configurations compares favorably against the conventional alternatives, and systems with intermediate to high capacity factors become the preferred alternatives. Another analysis compares net system costs for three configurations of CSP versus PV with batteries and PV with CTs. Under current technology costs, the least-expensive option is a combination of PV and CTs. However, under future cost assumptions, the optimal configuration of CSP becomes the most cost-effective option.« less

  8. 102. Interior view of utilidor passageway link between building nos. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    102. Interior view of utilidor passageway link between building nos. 101 and 102 showing waveguides on left and cable tray system on right sides. Note fire suppression water supply piping (upper center). Small maintenance 3-wheel vehicle at center (Note: similar vehicles still in use in 2001.) Official photograph BMEWS Project by Hansen, Photographic Services, Riverton, NJ, BMEWS, clear as negative no. A-101123. - Clear Air Force Station, Ballistic Missile Early Warning System Site II, One mile west of mile marker 293.5 on Parks Highway, 5 miles southwest of Anderson, Anderson, Denali Borough, AK

  9. Emergency Assessment of Postfire Debris-Flow Hazards for the 2009 Station Fire, San Gabriel Mountains, Southern California

    USGS Publications Warehouse

    Cannon, Susan H.; Gartner, Joseph E.; Rupert, Michael G.; Michael, John A.; Staley, Dennis M.; Worstell, Bruce B.

    2009-01-01

    This report presents an emergency assessment of potential debris-flow hazards from basins burned by the 2009 Station fire in Los Angeles County, southern California. Statistical-empirical models developed for postfire debris flows are used to estimate the probability and volume of debris-flow production from 678 drainage basins within the burned area and to generate maps of areas that may be inundated along the San Gabriel mountain front by the estimated volume of material. Debris-flow probabilities and volumes are estimated as combined functions of different measures of basin burned extent, gradient, and material properties in response to both a 3-hour-duration, 1-year-recurrence thunderstorm and to a 12-hour-duration, 2-year recurrence storm. Debris-flow inundation areas are mapped for scenarios where all sediment-retention basins are empty and where the basins are all completely full. This assessment provides critical information for issuing warnings, locating and designing mitigation measures, and planning evacuation timing and routes within the first two winters following the fire. Tributary basins that drain into Pacoima Canyon, Big Tujunga Canyon, Arroyo Seco, West Fork of the San Gabriel River, and Devils Canyon were identified as having probabilities of debris-flow occurrence greater than 80 percent, the potential to produce debris flows with volumes greater than 100,000 m3, and the highest Combined Relative Debris-Flow Hazard Ranking in response to both storms. The predicted high probability and large magnitude of the response to such short-recurrence storms indicates the potential for significant debris-flow impacts to any buildings, roads, bridges, culverts, and reservoirs located both within these drainages and downstream from the burned area. These areas will require appropriate debris-flow mitigation and warning efforts. Probabilities of debris-flow occurrence greater than 80 percent, debris-flow volumes between 10,000 and 100,000 m3, and high Combined Relative Debris-Flow Hazard Rankings were estimated in response to both short recurrence-interval (1- and 2-year) storms for all but the smallest basins along the San Gabriel mountain front between Big Tujunga Canyon and Arroyo Seco. The combination of high probabilities and large magnitudes determined for these basins indicates significant debris-flow hazards for neighborhoods along the mountain front. When the capacity of sediment-retention basins is exceeded, debris flows may be deposited in neighborhoods and streets and impact infrastructure between the mountain front and Foothill Boulevard. In addition, debris flows may be deposited in neighborhoods immediately below unprotected basins. Hazards to neighborhoods and structures at risk from these events will require appropriate debris-flow mitigation and warning efforts.

  10. Report for explosion and earthquake data acquired in the 1999 Seismic Hazards Investigation of Puget Sound (SHIPS), Washington

    USGS Publications Warehouse

    Brocher, Thomas M.; Pratt, Thomas L.; Miller, Kate C.; Tréhu, Anne M.; Snelson, Catherine M.; Weaver, Craig S.; Creager, Ken C.; Crosson, Robert S.; ten Brink, Uri S.; Alvarez, Marcos G.; Harder, Steven H.; Asudeh, Isa

    2000-01-01

    This report describes the acquisition, processing, and quality of seismic reflection and refraction data obtained in the Seattle basin, central Puget Lowland, western Washington, in September 1999 during the Seismic Hazards Investigation of Puget Sound (SHIPS). As a sequel to the 1998 SHIPS air gun experiment (also known as 'Wet SHIPS'), the 1999 experiment, nicknamed 'Dry SHIPS,' acquired a 112-km-long east-west trending multichannel seismic reflection and refraction line in the Seattle basin. One thousand and eight seismographs were deployed at a nominal spacing of 100 meters, and 29 shot points were detonated at approximately 4 km intervals along the seismic line. The wide-angle seismic profile was designed to (1) determine the E-W geometry of Seattle basin, (2) measure the seismic velocities within the basin, and (3) define the basement structure underlying the Seattle basin. In this report, we describe the acquisition of these data, discuss the processing and merging of the data into common shot gathers, and illustrate the acquired profiles. We also describe the format and content of the archival tapes containing the SEGY-formatted, common-shot gathers. Data quality is variable, but useful data were acquired from all 29 shot points fired along the Dry SHIPS seismic line. The data show pronounced travel time delays associated with the low velocity sedimentary rocks filling the Seattle basin. Thirty-five REFTEK stations, deployed at 4 km intervals along the Dry SHIPS line, recorded 26 regional earthquakes and blasts and 17 teleseismic events, including the main shock and several aftershocks of the Mw=7.6 Chi-Chi (Taiwan) earthquake of 9/20/1999. The teleseismic recordings of the Chi-Chi (Taiwan) mainshock provide useful signals down to 10 second periods. They document a significant (factor between 5 and 10) focusing of compressional- and shear-wave energy by the Seattle basin at periods between 1 and 2 seconds relative to 'bedrock' sites east and west of the basin. Signal durations in the Seattle basin were also substantially increased relative to 'bedrock' sites in the Olympic peninsula and Cascade foothills.

  11. June 2017 Ancho Canyon RF Collects: Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Junor, William; Layne, John Preston; Goglio, Joshua Henry

    2017-09-21

    We report the results from the June 8, 2017, Ancho Canyon RF collection. While bright, electromagnetic signals were seen close to the firing point, there were no detections of signals from the explosively-fired fuse (EFF) at a collection point about 600m distant on the East Mesa. The East Mesa site was unable to collect data because the uninterruptible power supply (UPS) was exhausted by the time of the shot. We did see signals from the EFF at the Bunker 57 antennas, about 123m distant from the Point 88 firing point. The strength of these signals is consistent with our limitedmore » knowledge of the collection antenna performance and the use of the standard model to predict the electric field strength. From our knowledge of the geometry of the EFF loop and the current in the loop in this test, and from measurements at the Bunker 57 site, we predict that we would have seen signals of about 50mV at 3.67MHz in a 100 kHz channel on the Rohde & Schwarz HE010 antennas at the East Mesa location. The noise oor there is about 0.113mV (based on the March 2017 collects). Thus we would have had an SNR of 53 dB from the collect, had the data collection system been running.« less

  12. MINEMOTION3D: A new set of Programs for Predicting Ground Motion From Explosions in Complex 3D Media

    NASA Astrophysics Data System (ADS)

    Tibuleac, I. M.; Bonner, J. L.; Orrey, J. L.; Yang, X.

    2004-12-01

    Predicting ground motion from complicated mining explosions is important for mines developing new blasting programs in regions where vibrations must be kept below certain levels. Additionally, predicting ground motion from mining explosions in complex 3D media is important for moment estimation for nuclear test treaty monitoring. Both problems have been addressed under the development of a new series of numerical prediction programs called MINEMOTION3D including 1) Generalized Fourier Methods to generate Green's functions in 3D media for a moment tensor source implementation and 2) MineSeis3D, a program that simulates seismograms for delay-fired mining explosions with a linear relationship between signals from small size individual shots. To test the programs, local recordings (5 - 23 km) of three production shots at a mine in northern Minnesota were compared to synthetic waveforms in 3D media. A non-zero value of the moment tensor component M12 was considered, to introduce a horizontal spall component into the waveform synthesis when the Green's functions were generated for each model. Methods using seismic noise crosscorrelation for improved inter-element subsurface structure estimation were also evaluated. Comparison of the observed and synthetic waveforms shows promising results. The shape and arrival times of the normalized synthetic and observed waveforms are similar for most of the stations. The synthetic and observed waveform amplitude fit is best for the vertical components in the mean 3D model and worst for the transversal components. The observed effect of spall on the waveform spectra was weak in the case of fragmentation delay fired commercial explosions. Commercial applications of the code could provide data needed for designing explosions which do not exceed ground vibration requirements posed by the U.S. Department of the Interior, Office of Surface Mining.

  13. The interaction between clothing and air weapon pellets.

    PubMed

    Wightman, G; Wark, K; Thomson, J

    2015-01-01

    Comparatively few studies have been carried out on air weapon injuries yet there are significant number of injuries and fatalities caused by these low power weapons because of their availability and the public perception that because they need no licence they are assumed to be safe. In this study ballistic gel was tested by Bloom and rupture tests to check on consistency of production. Two series of tests were carried out firing into unclothed gel blocks and blocks loosely covered by different items of clothing to simulate attire (tee shirt, jeans, fleece, and jacket). The damage to the clothing caused by different shaped pellets when fired at different ranges was examined. The apparent hole size was affected by the shape of pellet (round, pointed, flat and hollow point) and whether damage was predominantly caused by pushing yarn to one side or by laceration of the yarn through cutting or tearing. The study also compared penetration into clothed gel and unclothed gel under identical conditions, and loose clothing greatly reduced penetration. With loose clothing at 9.1 m range clothing reduced penetration to 50-70% of the penetration of unclothed gel but at 18.3m range only 7 out of 36 shots penetrated the gel. This cannot be accounted for by the energy loss at the longer range (3-7% reduction from 9.1 m to 18.3 m range in unclothed gels) and it is suggested that impulse may have a role to play. Shots that did not penetrate the gel were used to estimate the possible stopping time for the pellet (around 75 μs) and force (1700 N) or stress (100 MPa) required to bring the pellet to a halt. Even with these low energy projectiles, cloth fibres were entrained in the gel showing the potential for penetration of the body and subsequent infection. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  14. Benefit from NASA

    NASA Image and Video Library

    2004-04-15

    Firefighters are like astronauts. They both face dangerous, even hostile environments such as a building full of fire and the vacuum of space. They are both get breathing air from tanks on their backs. Early in the 1970's, NASA began working to improve firefighter breathing systems, which had hardly changed since the 1940s. NASA's Johnson Space Center conducted a 4-year program that applied technology from the portable life support systems used by Apollo astronauts on the moon. The new breathing system is made up of an air bottle, a frame and harness, a face mask, and a warning device. The new system weighs less than 20 pounds, one-third less than the old gear. The new air bottle provides 30 minutes of breathing air, as much as the old system. Like a good hiker's backpack, the new system puts the weight on the firefighter's hips rather than the shoulders. The face mask provides better visibility and the warning device lets the firefighter know when air in the bottle is low. Though they have made many design modifications and refinements, manufacturers of breathing apparatus still incorporate the original NASA technology.

  15. On the physics of momentum in ballistics: can the human body be displaced or knocked down by a small arms projectile?

    PubMed

    Karger, B; Kneubuehl, B P

    1996-01-01

    Shooting incidents are often portrayed as resulting in a sometimes violent backwards displacement of the victim. This opinion is also not infrequently held by expert witnesses. The physical force responsible for this would be momentum (mass x velocity). The physics of momentum in ballistic injury is explained in detail. The maximum momentum transferred from different small arms projectiles including large calibre rifles and a 12-gauge shotgun only results in a backwards motion of a 80 kg target body of 0.01-0.18 m/s, which is negligible compared to the velocity of a pedestrian (1-2 m/s). Furthermore, counterbalance is constantly maintained by neurophysiological reflexes. So the effect of the momentum transferred from the missile is virtually zero and there is no backwards motion of the person shot. Empirical evidence verifying these calculations can be obtained from hunting big game, from human gunshot victims and from a video documentary demonstrating the lack of any backwards motion of a person wearing body armour after hits from a centre fire rifle. So the alleged backwards hurling of a person shot is nothing but a myth which should be refuted not only because it is incorrect but also because it can result in miscarriages of justice.

  16. Shooter position estimation with muzzle blast and shockwave measurements from separate locations

    NASA Astrophysics Data System (ADS)

    Grasing, David

    2016-05-01

    There are two acoustical events associated with small arms fire: the muzzle blast (created by bullets being expelled from the barrel of the weapon), and the shockwave (created by bullets which exceed the speed of sound). Assuming the ballistics of a round are known, the times and directions of arrival of the acoustic events furnish sufficient information to determine the origin of the shot. Existing methods tacitly assume that it is a single sensor which makes measurements of the times and direction of arrival. If the sensor is located past the point where the bullet goes transonic or if the sensor is far off the axis of the shot line a single sensor localization become highly inaccurate due to the ill-conditioning of the localization problem. In this paper, a more general approach is taken which allows for localizations from measurements made at separate locations. There are considerable advantages to this approach, the most noteworthy of which is the improvement in localization accuracy due to the improvement in the conditioning of the problem. Additional benefits include: the potential to locate in cases where a single sensor has insufficient information, furnishing high quality initialization to data fusion algorithms, and the potential to identify the round from a set of possible rounds.

  17. Effect of Shot Peening in Different Shot Distance and Shot Angle on Surface Morphology, Surface Roughness and Surface Hardness of 316L Biomaterial

    NASA Astrophysics Data System (ADS)

    Umbu Kondi Maliwemu, Erich; Malau, Viktor; Iswanto, Priyo Tri

    2018-01-01

    Shot peening is a mechanical surface treatment with a beneficial effect to generate compressive residual stress caused by plastic deformation on the surface of material. This plastic deformation can improve the surface characteristics of metallic materials, such as modification of surface morphology, surface roughness, and surface hardness. The objective of this study is to investigate the effect of shot peening in different shot distance and shot angle on surface morphology, surface roughness, and surface hardness of 316L biomaterial. Shot distance was varied at 6, 8, 10, and 12 cm and shot angle at 30, 60, and 90°, working pressure at 7 kg/cm2, shot duration for 20 minutes, and using steel balls S-170 with diameter of 0.6 mm. The results present that the shot distance and shot angle of shot peening give the significant effect to improve the surface morphology, surface roughness, and surface hardness of 316 L biomaterial. Shot peening can increase the surface roughness by the increasing of shot distance and by the decreasing of shot angle. The nearest shot distance (6 cm) and the largest shot angle (90°) give the best results on the grain refinement with the surface roughness of 1.04 μm and surface hardness of 534 kg/mm2.

  18. Development of building security integration system using sensors, microcontroller and GPS (Global Positioning System) based android smartphone

    NASA Astrophysics Data System (ADS)

    Sihombing, P.; Siregar, Y. M.; Tarigan, J. T.; Jaya, I.; Turnip, A.

    2018-03-01

    Security system is one of the common problems to protect an environment such as personal house or a warehouse. There are numerous methods and technologies that can be used as part of a security system. In this paper, we present a security system that offers a better efficiency. The purpose of this study is to build a system that can monitor home security at any time in particular fire and theft. Through sensors, the system will be able to provide warning information of hazard conditions via LCD monitor, sound, and alarm. This information will be sent automatically to the home owner’s smartphone as well as to the corresponding to the security agency. Thus the prevention of theft and fire hazards can be immediately anticipated by the police and firefighters. The system will also notify the position of the coordinates of the location of the building (the house) by a link to the Google map in order to make it easier to get the location quickly.

  19. Study on Plastic Deformation Characteristics of Shot Peening of Ni-Based Superalloy GH4079

    NASA Astrophysics Data System (ADS)

    Zhong, L. Q.; Liang, Y. L.; Hu, H.

    2017-09-01

    In this paper, the X-ray stress diffractometer, surface roughness tester, field emission scanning electron microscope(SEM), dynamic ultra-small microhardness tester were used to measure the surface residual stress and roughness, topography and surface hardness changes of GH4079 superalloy, which was processed by metallographic grinding, turning, metallographic grinding +shot peening and turning + shot peening. Analysized the effects of shot peening parameters on shot peening plastic deformation features; and the effects of the surface state before shot peening on shot peening plastic deformation characteristics. Results show that: the surface residual compressive stress, surface roughness and surface hardness of GH4079 superalloy were increased by shot peening, in addition, the increment of the surface residual compressive stress, surface roughness and surface hardness induced by shot peening increased with increasing shot peening intensity, shot peening time, shot peening pressure and shot hardness, but harden layer depth was not affected considerably. The more plastic deformation degree of before shot peening surface state, the less increment of the surface residual compressive stress, surface roughness and surface hardness induced by shot peening.

  20. P-23 Highlights 6/10/12: Cygnus Dual Beam Radiographic Facility Refurbishment completed at U1A tunnel in Nevada NNSS meeting Level 2 milestone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deyoung, Anemarie; Smith, John R.

    2012-05-03

    A moratorium was placed on U.S. underground nuclear testing in 1992. In response, the Stockpile Stewardship Program was created to maintain readiness of the existing nuclear inventory through several efforts such as computer modeling, material analysis, and subcritical nuclear experiments (SCEs). As in the underground test era, the Nevada National Security Site (NNSS), formerly the Nevada Test Site, provides a safe and secure environment for SCEs by the nature of its isolated and secure facilities. A major tool for SCE diagnosis installed in the 05 drift laboratory is a high energy x-ray source used for time resolved imaging. This toolmore » consists of two identical sources (Cygnus 1 and Cygnus 2) and is called the Cygnus Dual Beam Radiographic Facility (Figs. 2-6). Each Cygnus machine has 5 major elements: Marx Generator, Pulse Forming Line (PFL), Coaxial Transmission Line (CTL), 3-cell Inductive Voltage Adder (IVA), and Rod Pinch Diode. Each machine is independently triggered and may be fired in separate tests (staggered mode), or in a single test where there is submicrosecond separation between the pulses (dual mode). Cygnus must operate as a single shot machine since on each pulse the diode electrodes are destroyed. The diode is vented to atmosphere, cleaned, and new electrodes are inserted for each shot. There is normally two shots per day on each machine. Since its installation in 2003, Cygnus has participated in: 4 Subcritical Experiments (Armando, Bacchus, Barolo A, and Barolo B), a 12 shot plutonium physics series (Thermos), and 2 plutonium step wedge calibration series (2005, 2011), resulting in well over 1000 shots. Currently the Facility is in preparation for 2 SCEs scheduled for this calendar year - Castor and Pollux. Cygnus has performed well during 8 years of operations at NNSS. Many improvements in operations and performance have been implemented during this time. Throughout its service at U1a, major maintenance and replacement of many hardware items were delayed due to programmatic requirements. It is anticipated that Cygnus will be in service at U1a for another 5 years. With this assumption, it was realized that significant resources and effort should be allotted to bring the hardware back to its original condition, or even to improve elements when appropriate. The Cygnus Refurbishment and Enhancement Project started in April, 2011 with the intent to encompass a major overhaul of Cygnus.« less

  1. Variance and Rate-of-Change as Early Warning Signals for a Critical Transition in an Aquatic Ecosystem State: A Test Case From Tasmania, Australia

    NASA Astrophysics Data System (ADS)

    Beck, Kristen K.; Fletcher, Michael-Shawn; Gadd, Patricia S.; Heijnis, Henk; Saunders, Krystyna M.; Simpson, Gavin L.; Zawadzki, Atun

    2018-02-01

    Critical transitions in ecosystem states are often sudden and unpredictable. Consequently, there is a concerted effort to identify measurable early warning signals (EWS) for these important events. Aquatic ecosystems provide an opportunity to observe critical transitions due to their high sensitivity and rapid response times. Using palaeoecological techniques, we can measure properties of time series data to determine if critical transitions are preceded by any measurable ecosystem metrics, that is, identify EWS. Using a suite of palaeoenvironmental data spanning the last 2,400 years (diatoms, pollen, geochemistry, and charcoal influx), we assess whether a critical transition in diatom community structure was preceded by measurable EWS. Lake Vera, in the temperate rain forest of western Tasmania, Australia, has a diatom community dominated by Discostella stelligera and undergoes an abrupt compositional shift at ca. 820 cal yr BP that is concomitant with increased fire disturbance of the local vegetation. This shift is manifest as a transition from less oligotrophic acidic diatom flora (Achnanthidium minutissimum, Brachysira styriaca, and Fragilaria capucina) to more oligotrophic acidic taxa (Frustulia elongatissima, Eunotia diodon, and Gomphonema multiforme). We observe a marked increase in compositional variance and rate-of-change prior to this critical transition, revealing these metrics are useful EWS in this system. Interestingly, vegetation remains complacent to fire disturbance until after the shift in the diatom community. Disturbance taxa invade and the vegetation system experiences an increase in both compositional variance and rate-of-change. These trends imply an approaching critical transition in the vegetation and the probable collapse of the local rain forest system.

  2. Progress in the development of a S-RETGEM-based detector for an early forest fire warning system

    NASA Astrophysics Data System (ADS)

    Charpak, G.; Benaben, P.; Breuil, P.; Martinengo, P.; Nappi, E.; Peskov, V.

    2009-12-01

    We present a prototype of a Strip Resistive Thick GEM (S-RETGEM) photosensitive gaseous detector filled with Ne and ethylferrocene (EF) vapours at a total pressure of 1 atm for an early forest fire detection system. Measurements show that it is one hundred times more sensitive than the best commercial ultraviolet (UV) flame detectors; and therefore, it is able to reliably detect a flame of ~ 1.5 × 1.5 × 1.5 m3 at a distance of about 1 km. An additional and unique feature of this detector is its imaging capability, which in combination with other techniques, may significantly reduce false fire alarms rate when operating in an automatic mode. Preliminary results conducted with air-filled photosensitive gaseous detectors are also presented. The main advantages of this approach include both the simplicity of manufacturing and affordability of construction materials such as plastics and glues specifically reducing detector production cost. The sensitivity of these air-filled detectors at certain conditions may be as high as those filled with Ne and EF. Long-term tests of such sealed detectors indicate a significant progress in this direction. We believe that our detectors utilized in addition to other flame and smoke sensors will exceptionally increase the capability to detect forest fire at a very early stage of development. Our future efforts will be focused on attempts to commercialize such detectors utilizing our aforementioned findings.

  3. Monitoring Fires from Space and Getting Data in to the hands of Users: An Example from NASA's Fire Information for Resource Management System (FIRMS)

    NASA Astrophysics Data System (ADS)

    Davies, D.; Wong, M.; Ilavajhala, S.; Molinario, G.; Justice, C. O.

    2012-12-01

    This paper discusses the broad uptake of MODIS near-real-time (NRT) active fire data for applications. Prior to the launch of MODIS most real-time satellite-derived fire information was obtained from NOAA AVHRR via direct broadcast (DB) systems. Whilst there were efforts to make direct broadcast stations affordable in developing countries, such as through the Local Applications of Satellite Remote Technologies (LARST), these systems were relatively few and far between and required expertise to manage and operate. One such system was in Etosha National Park (ENP) in Namibia. Prior to the installation of the AVHRR DB system in ENP, fires were reported by rangers and the quality, accuracy and timing of reports was variable. With the introduction of the DB station, early warning of fires improved and fire maps could be produced for park managers within 2-3 hours by staff trained to process data, interpret images and produce maps. Up keep and maintenance of such systems was relatively costly for parks with limited resources therefore when global fire data from MODIS became available uptake was widespread. NRT data from MODIS became availalbe through a collaboration between the MODIS Fire Team and the US Forest Service (USFS) Remote Sensing Applications Center to provide rapid access to imagery to help fight the Montana wildfires of 2001. This prompted the development of a Rapid Response System for fire data that eventually led to the operational use of MODIS data by the USFS for fire monitoring. Building on this success, the Fire Information for Resource Management System (FIRMS) project was funded by NASA Applications, and developed under the umbrella of the GOFC-GOLD Fire program, to further improve products and services for the global fire information community. FIRMS was developed as a web-based geospatial tool, offering a range of geospatial data services, including a fire email alert service which is widely used around the world. FIRMS was initially developed to meet the needs of protected area managers, who like the managers in ENP had limited resources to cover large, remote areas. It was quickly realized that these data could be used for a wide range of applications beyond wildfire management including ecological studies, informing fire policy and public outreach. Today, FIRMS sends approximately 2000 email alerts daily to users in over 120 countries. In addition to the direct users of the MODIS fire data, there are a growing number of brokers who add value to the data, by combining them with targeted geospatial information and re-distribute the information. In addition to the English, French and Spanish fire notifications sent out by FIRMS, some brokers translate the alerts in to local languages and distribute them in Thailand, Indonesia, Russia and India.

  4. Space Shuttle Projects

    NASA Image and Video Library

    1987-05-27

    This photograph is a long shot view of a full scale solid rocket motor (SRM) for the solid rocket booster (SRB) being test fired at Morton Thiokol's Wasatch Operations in Utah. The twin boosters provide the majority of thrust for the first two minutes of flight, about 5.8 million pounds, augmenting the Shuttle's main propulsion system during liftoff. The major design drivers for the SRM's were high thrust and reuse. The desired thrust was achieved by using state-of-the-art solid propellant and by using a long cylindrical motor with a specific core design that allows the propellant to burn in a carefully controlled marner. Under the direction of the Marshall Space Flight Center, the SRM's are provided by the Morton Thiokol Corporation.

  5. Pulsed Plasma Thruster Plume Study: Symmetry and Impact on Spacecraft Surfaces

    NASA Technical Reports Server (NTRS)

    Arrington, Lynn A.; Marrese, Colleen M.; Blandino, John J.

    2000-01-01

    Twenty-four witness plates were positioned on perpendicular arrays near a breadboard Pulsed Plasma Thruster (PPT) to collect plume constituents for analysis. Over one million shots were fired during the experiment at 43 J using fluorocarbon polymer propellant. The asymmetry of the film deposition on the witness plates was investigated with mass and thickness measurements and correlated with off-axis thrust vector measurements. The composition of the films was determined. The transmittance and reflectance of the films were measured and the absorption coefficients were calculated in the wavelength range from 350 to 1200 mn. These data were applied to calculate the loss in signal intensity through the films, which will impact the visibility of spaceborne interferometer systems positioned by these thrusters.

  6. Single vs. dual color fire detection systems: operational tradeoffs

    NASA Astrophysics Data System (ADS)

    Danino, Meir; Danan, Yossef; Sinvani, Moshe

    2017-10-01

    In attempt to supply a reasonable fire plume detection, multinational cooperation with significant capital is invested in the development of two major Infra-Red (IR) based fire detection alternatives, single-color IR (SCIR) and dual-color IR (DCIR). False alarm rate was expected to be high not only as a result of real heat sources but mainly due to the IR natural clutter especially solar reflections clutter. SCIR uses state-of-the-art technology and sophisticated algorithms to filter out threats from clutter. On the other hand, DCIR are aiming at using additional spectral band measurements (acting as a guard), to allow the implementation of a simpler and more robust approach for performing the same task. In this paper we present the basics of SCIR & DCIR architecture and the main differences between them. In addition, we will present the results from a thorough study conducted for the purpose of learning about the added value of the additional data available from the second spectral band. Here we consider the two CO2 bands of 4-5 micron and of 2.5-3 micron band as well as off peak band (guard). The findings of this study refer also to Missile warning systems (MWS) efficacy, in terms of operational value. We also present a new approach for tunable filter to such sensor.

  7. Emergency assessment of post-fire debris-flow hazards for the 2013 Springs Fire, Ventura County, California

    USGS Publications Warehouse

    Staley, Dennis M.

    2014-01-01

    Wildfire can significantly alter the hydrologic response of a watershed to the extent that even modest rainstorms can produce dangerous flash floods and debris flows. In this report, empirical models are used to predict the probability and magnitude of debris-flow occurrence in response to a 10-year rainstorm for the 2013 Springs fire in Ventura County, California. Overall, the models predict a relatively high probability (60–80 percent) of debris flow for 9 of the 99 drainage basins in the burn area in response to a 10-year recurrence interval design storm. Predictions of debris-flow volume suggest that debris flows may entrain a significant volume of material, with 28 of the 99 basins identified as having potential debris-flow volumes greater than 10,000 cubic meters. These results of the relative combined hazard analysis suggest there is a moderate likelihood of significant debris-flow hazard within and downstream of the burn area for nearby populations, infrastructure, wildlife, and water resources. Given these findings, we recommend that residents, emergency managers, and public works departments pay close attention to weather forecasts and National Weather Service-issued Debris Flow and Flash Flood Outlooks, Watches, and Warnings, and that residents adhere to any evacuation orders.

  8. The right way to be fired.

    PubMed

    Stybel, L J; Peabody, M

    2001-01-01

    Nearly all of us will lose our jobs sometime, but is there a right way to be terminated? What differentiates fired employees who make the best of their situations from those who do not? One answer is mind-set. Many workers unconsciously hold a "tenure mind-set," believing in the promise of employment security. By contrast, other workers hold an "assignment mentality," seeing each job as one in a series of impermanent, career-building stepping-stones. Most corporate board members and CEOs have this latter mind-set and consider their executives to be filling terminal assignments; people who possess this mentality usually rebound swiftly when fired. But when employees who hold a tenure mind-set are suddenly fired or laid off, the authors say, they can fall into three common traps. Executives who have overidentified with their jobs and feel indispensable to their organizations get caught in the "lost identity" trap; they react to termination with anger and bitterness. In the "lost family" trap, employees possess tight-knit, emotional bonds with coworkers. When terminated, they feel betrayed and rejected. And finally, some introverted executives fall into the "lost ego" trap; they quietly retreat without negotiating fair termination packages and may settle for less satisfying work the next time around. To prepare for the eventuality of termination, the authors suggest that executives adopt the assignment mind-set at all times. They should keep their social networks alive, include a termination clause in employment contracts, and consider hiring an agent. If warning signs warrant, they might even volunteer to be terminated. By assuming control over the way they are fired, people can gain control over their careers.

  9. Autonomous UAV-Based Mapping of Large-Scale Urban Firefights

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Snarski, S; Scheibner, K F; Shaw, S

    2006-03-09

    This paper describes experimental results from a live-fire data collect designed to demonstrate the ability of IR and acoustic sensing systems to detect and map high-volume gunfire events from tactical UAVs. The data collect supports an exploratory study of the FightSight concept in which an autonomous UAV-based sensor exploitation and decision support capability is being proposed to provide dynamic situational awareness for large-scale battalion-level firefights in cluttered urban environments. FightSight integrates IR imagery, acoustic data, and 3D scene context data with prior time information in a multi-level, multi-step probabilistic-based fusion process to reliably locate and map the array of urbanmore » firing events and firepower movements and trends associated with the evolving urban battlefield situation. Described here are sensor results from live-fire experiments involving simultaneous firing of multiple sub/super-sonic weapons (2-AK47, 2-M16, 1 Beretta, 1 Mortar, 1 rocket) with high optical and acoustic clutter at ranges up to 400m. Sensor-shooter-target configurations and clutter were designed to simulate UAV sensing conditions for a high-intensity firefight in an urban environment. Sensor systems evaluated were an IR bullet tracking system by Lawrence Livermore National Laboratory (LLNL) and an acoustic gunshot detection system by Planning Systems, Inc. (PSI). The results demonstrate convincingly the ability for the LLNL and PSI sensor systems to accurately detect, separate, and localize multiple shooters and the associated shot directions during a high-intensity firefight (77 rounds in 5 sec) in a high acoustic and optical clutter environment with no false alarms. Preliminary fusion processing was also examined that demonstrated an ability to distinguish co-located shooters (shooter density), range to <0.5 m accuracy at 400m, and weapon type.« less

  10. MTR WING, TRA604, INTERIOR. BASEMENT. INTERIOR VIEW FROM SAME LOCATION ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    MTR WING, TRA-604, INTERIOR. BASEMENT. INTERIOR VIEW FROM SAME LOCATION IN WEST CORRIDOR AS PHOTO ID-33-G-42 BUT CAMERA FACES SOUTH. SIGN ON DOOR FOR "PIPE TUNNEL" WARNS OF RADIOLOGICAL AND ASBESTOS HAZARDS. DOOR HAS METAL HASPS. SIGN ON OVERHEAD WASTE HEAT RECOVERY PIPES SAYS THEY CONTAIN "ASBESTOS FREE INSULATION." FIRE DOOR AT LEFT LEADS TO STAIRWAY TO FIRST FLOOR. DOOR AT RIGHT LEADS TO ROOM WHICH ONCE CONTAINED MTR LIBRARY. INL NEGATIVE NO. HD46-13-4. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID

  11. Solar photovoltaics: Stand alone applications

    NASA Astrophysics Data System (ADS)

    Deyo, J. N.

    1980-11-01

    The Lewis Research Center involvement in space photovoltaic research and development and in using photovoltaics for terrestrial applications is described with emphasis on applications in which the normal source of power may be a diesel generator, batteries, or other types of power not connected to a utility grid. Once an application is processed, technology is developed and demonstrated with a user who participates in the cost and furnishes the site. Projects completed related to instruments, communication, refrigeration, and highways, are described as well as warning systems, weather stations, fire lookouts, and village power systems. A commercially available photovoltaic powered electric fence charger is the result of Lewis research and development.

  12. FY14 LLNL OMEGA Experimental Programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heeter, R. F.; Fournier, K. B.; Baker, K.

    In FY14, LLNL’s High-Energy-Density Physics (HED) and Indirect Drive Inertial Confinement Fusion (ICF-ID) programs conducted several campaigns on the OMEGA laser system and on the EP laser system, as well as campaigns that used the OMEGA and EP beams jointly. Overall these LLNL programs led 324 target shots in FY14, with 246 shots using just the OMEGA laser system, 62 shots using just the EP laser system, and 16 Joint shots using Omega and EP together. Approximately 31% of the total number of shots (62 OMEGA shots, 42 EP shots) shots supported the Indirect Drive Inertial Confinement Fusion Campaign (ICF-ID).more » The remaining 69% (200 OMEGA shots and 36 EP shots, including the 16 Joint shots) were dedicated to experiments for High- Energy-Density Physics (HED). Highlights of the various HED and ICF campaigns are summarized in the following reports.« less

  13. Monitoring Regional Forest Disturbances across the US with near Real Time MODIS NDVI Products Resident to the ForWarn Forest Threat Early Warning System

    NASA Technical Reports Server (NTRS)

    Spruce, Joseph P.; Hargrove, William W.; Gasser, Gerald

    2013-01-01

    Forest threats across the US have become increasingly evident in recent years. Sometimes these have resulted in regionally evident disturbance progressions (e.g., from drought, bark beetle outbreaks, and wildfires) that can occur across multiyear durations and have resulted in extensive forest overstory mortality. In addition to stand replacement disturbances, other forests are subject to ephemeral, sometimes yearly defoliation from various insects and varying types and intensities of ephemeral damage from storms. Sometimes, after prolonged severe disturbance, signs of recovery in terms of Normalized Difference Vegetation Index (NDVI) can occur. The growing prominence and threat of forest disturbances in part have led to the formation and implementation of the 2003 Healthy Forest Restoration Act which mandated that national forest threat early warning system be developed and deployed. In response, the US Forest Service collaborated with NASA, DOE Oakridge National Laboratory, and the USGS Eros Data Center to build and roll-out the near real time ForWarn early warning system for monitoring regionally evident forest disturbances. Given the diversity of disturbance types, severities, and durations, ForWarn employs multiple historical baselines that are used with current NDVI to derive a suite of six forest change products that are refreshed every 8 days. ForWarn employs daily quarter kilometer MODIS NDVI data from the Aqua and Terra satellites, including MOD13 data for deriving historical baseline NDVIs and eMODIS 7 NDVI for compiling current NDVI. In doing so, the Time Series Product Tool and the Phenological Parameters Estimation Tool are used to temporally de-noise, fuse, and aggregate current and historical MODIS NDVIs into 24 day composites refreshed every 8 days with 46 dates of products per year. The 24 day compositing interval enables disturbances to be detected, while minimizing the frequency of residual atmospheric contamination. Forest change products are computed versus the previous 1, previous 3, and all previous years in the MODIS record for a given 24 day interval. Other "weekly" forest change products include one computed using an adaptive length compositing method for quicker detection of disturbances, two others that adjust for seasonal fluctuations in normal vegetation phenology (e.g., early versus late springs). This overall approach enables forest disturbance dynamics from a variety of regionally evident biotic and abiotic forest disturbances to be viewed and assessed through the calendar year. The change products are also being utilized for forest change trend analysis and for developing regional forest overstory mortality products. ForWarn's forest change products are used to alert forest health specialists about new forest disturbances. Such alerts are also typically based on available Landsat, aerial, and ground data as well as communications with forest health specialists and previous experience. ForWarn products have been used to detect and track many types of regional disturbances to multiple forest types, including defoliation from caterpillars and severe storms, as well as mortality from both biotic and abiotic agents (e.g., bark beetles, drought, fire, anthropogenic clearing). ForWarn offers products that could be combined with other geospatial data on forest biomass to assess forest disturbance carbon impacts within the conterminous US.

  14. Southern California Wildfires Observed by NASA MISR

    NASA Image and Video Library

    2016-06-24

    The Los Angeles area is currently suffering the effects of three major wildfires that are blanketing the area with smoke. Over the past few days, Southern California has experienced record-breaking temperatures, topping 110 degrees Fahrenheit in some cities. The heat, in combination with offshore winds, helped to stoke the Sherpa Fire west of Santa Barbara, which has been burning since June 15, 2016. Over the weekend of June 18-19, this fire rapidly expanded in size, forcing freeway closures and evacuations of campgrounds and state beaches. On Monday, June 20, two new fires ignited in the San Gabriel Mountains north of Azusa and Duarte, together dubbed the San Gabriel Complex Fire. They have burned more than 4,900 acres since June 20, sending up plumes of smoke visible to many in the Los Angeles basin and triggering air quality warnings. More than 1,400 personnel have been battling the blazes in the scorching heat, and evacuations were ordered for neighborhoods in the foothills. On June 21, the Multi-angle Imaging SpectroRadiometer (MISR) instrument aboard NASA's Terra satellite captured this view of the San Gabriel Mountains and Los Angeles Basin from its 46-degree forward-viewing camera, which enhances the visibility of the smoke compared to the more conventional nadir (vertical) view. The width of this image is about 75 miles (120 kilometers) across. Smoke from the San Gabriel Complex Fire is visible at the very right of the image. Stereoscopic analysis of MISR's multiple camera angles is used to compute the height of the smoke plume from the San Gabriel Complex Fire. In the right-hand image, these heights are superimposed on the underlying image. The color scale shows that the plume is not much higher than the surrounding mountains. As a result, much of the smoke is confined to the local area. http://photojournal.jpl.nasa.gov/catalog/PIA20718

  15. 50 CFR 20.134 - Approval of nontoxic shot types and shot coatings.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... erosion and absorption of one shot or coated shot in a 24-hour period. Define the nature of the toxic...) with one U.S. No. 4 pellet of lead shot. Dose each bird in one group of 8 males and 8 females with 8 U... males and 8 females with one U.S. No. 4 pellet of the candidate shot type or shot with the proposed...

  16. The variable and chaotic nature of professional golf performance.

    PubMed

    Stöckl, Michael; Lamb, Peter F

    2018-05-01

    In golf, unlike most other sports, individual performance is not the result of direct interactions between players. Instead decision-making and performance is influenced by numerous constraining factors affecting each shot. This study looked at the performance of PGA TOUR golfers in 2011 in terms of stability and variability on a shot-by-shot basis. Stability and variability were assessed using Recurrence Quantification Analysis (RQA) and standard deviation, respectively. About 10% of all shots comprised short stable phases of performance (3.7 ± 1.1 shots per stable phase). Stable phases tended to consist of shots of typical performance, rather than poor or exceptional shots; this finding was consistent for all shot categories. Overall, stability measures were not correlated with tournament performance. Variability across all shots was not related to tournament performance; however, variability in tee shots and short approach shots was higher than for other shot categories. Furthermore, tee shot variability was related to tournament standing: decreased variability was associated with better tournament ranking. The findings in this study showed that PGA TOUR golf performance is chaotic. Further research on amateur golf performance is required to determine whether the structure of amateur golf performance is universal.

  17. Shot model parameters for Cygnus X-1 through phase portrait fitting

    NASA Technical Reports Server (NTRS)

    Lochner, James C.; Swank, J. H.; Szymkowiak, A. E.

    1991-01-01

    Shot models for systems having about 1/f power density spectrum are developed by utilizing a distribution of shot durations. Parameters of the distribution are determined by fitting the power spectrum either with analytic forms for the spectrum of a shot model with a given shot profile, or with the spectrum derived from numerical realizations of trial shot models. The shot fraction is specified by fitting the phase portrait, which is a plot of intensity at a given time versus intensity at a delayed time and in principle is sensitive to different shot profiles. These techniques have been extensively applied to the X-ray variability of Cygnus X-1, using HEAO 1 A-2 and an Exosat ME observation. The power spectra suggest models having characteristic shot durations lasting from milliseconds to a few seconds, while the phase portrait fits give shot fractions of about 50 percent. Best fits to the portraits are obtained if the amplitude of the shot is a power-law function of the duration of the shot. These fits prefer shots having a symmetric exponential rise and decay. Results are interpreted in terms of a distribution of magnetic flares in the accretion disk.

  18. Using RAQMS Chemical Transport Model, Aircraft In-situ and Satellite Data to Verify Ground-based Biomass Burning Emissions from the Extreme Fire Event in Boreal Alaska 2004

    NASA Astrophysics Data System (ADS)

    Soja, A. J.; Pierce, R. B.; Al-Saadi, J. A.; Alvarado, E.; Sandberg, D. V.; Ottmar, R. D.; Kittaka, C.; McMillian, W. W.; Sachse, G. W.; Warner, J. X.; Szykman, J. J.

    2006-12-01

    Current climate change scenarios are predicted to result in increased biomass burning, particularly in boreal regions. Biomass burning events feedback to the climate system by altering albedo (affecting the energy balance) and by direct and indirect fire emissions. Additionally, fire emissions influence air quality and human health downwind of burning. Biomass burning emission estimates are difficult to quantify in near-real-time and accurate estimates are useful for large-scale chemical transport models, which could be used to warn the public of potential health risks and for climate modeling. In this talk, we describe a methodology to quantify emissions, validate those emission estimates, transport the emissions and verify the resultant CO plume 100's of kilometers from the fire events using aircraft in-situ and satellite data. First, we developed carbon consumption estimates that are specifically designed for near-real-time use in conjunction with satellite-derived fire data for regional- to global-chemical transport models. Large-scale carbon consumption estimates are derived for 10 ecozones across North America and each zone contains 3 classes of severity. The estimates range is from a low severity 3.11 t C ha-1 estimate from the Western Taiga Shield to a high severity 59.83 t C ha-1 estimate from the Boreal Cordillera. These estimates are validated using extensive supplementary ground-based Alaskan data. Then, the RAQMS chemical transport model ingests these data and transports CO from the Alaskan 2004 fires across North America, where results are compared with in-situ flight CO data measured during INTEX-A and satellite-based CO data (AIRS and MOPITT). Ground-based CO is 6 to 14 times greater than the typically modeled fire climatology. RAQMS often overestimates CO in the biomass plumes in comparison to satellite- derived CO data and we suspect this may be due to the satellite instruments low sensitivity to planetary boundary layer CO, which is prevalent in the near field plumes, and also the assumption of high-severity fires throughout the burning season. RAQMS underestimates biomass CO in comparison to in-situ CO data (146 out of 148 ascents and descents), and we suspect this may be due to RAQMS difficulty in defining narrow fire plumes due to the 1.4° x 1.4° resolution.

  19. Enhanced speed in fluorescence imaging using beat frequency multiplexing

    NASA Astrophysics Data System (ADS)

    Mikami, Hideharu; Kobayashi, Hirofumi; Wang, Yisen; Hamad, Syed; Ozeki, Yasuyuki; Goda, Keisuke

    2016-03-01

    Fluorescence imaging using radiofrequency-tagged emission (FIRE) is an emerging technique that enables higher imaging speed (namely, temporal resolution) in fluorescence microscopy compared to conventional fluorescence imaging techniques such as confocal microscopy and wide-field microscopy. It works based on the principle that it uses multiple intensity-modulated fields in an interferometric setup as excitation fields and applies frequency-division multiplexing to fluorescence signals. Unfortunately, despite its high potential, FIRE has limited imaging speed due to two practical limitations: signal bandwidth and signal detection efficiency. The signal bandwidth is limited by that of an acousto-optic deflector (AOD) employed in the setup, which is typically 100-200 MHz for the spectral range of fluorescence excitation (400-600 nm). The signal detection efficiency is limited by poor spatial mode-matching between two interfering fields to produce a modulated excitation field. Here we present a method to overcome these limitations and thus to achieve higher imaging speed than the prior version of FIRE. Our method achieves an increase in signal bandwidth by a factor of two and nearly optimal mode matching, which enables the imaging speed limited by the lifetime of the target fluorophore rather than the imaging system itself. The higher bandwidth and better signal detection efficiency work synergistically because higher bandwidth requires higher signal levels to avoid the contribution of shot noise and amplifier noise to the fluorescence signal. Due to its unprecedentedly high-speed performance, our method has a wide variety of applications in cancer detection, drug discovery, and regenerative medicine.

  20. Muzzle flash localization for the dismounted soldier

    NASA Astrophysics Data System (ADS)

    Kennedy Scott, Will

    2015-05-01

    The ability to accurately and rapidly know the precise location of enemy fire would be a substantial capability enhancement to the dismounted soldier. Acoustic gun-shot detections systems can provide an approximate bearing but it is desired to precisely know the location (direction and range) of enemy fire; for example to know from `which window' the fire is coming from. Funded by the UK MOD (via Roke Manor Research) QinetiQ is developing an imaging solution built around an InGaAs camera. This paper presents work that QinetiQ has undertaken on the Muzzle Flash Locator system. Key technical challenges that have been overcome are explained and discussed in this paper. They include; the design of the optical sensor and processing hardware to meet low size, weight and power requirements; the algorithm approach required to maintain sensitivity whilst rejecting false alarms from sources such as close passing insects and sun glint from scene objects; and operation on the move. This work shows that such a sensor can provide sufficient sensitivity to detect muzzle flash events to militarily significant ranges and that such a system can be combined with an acoustic gunshot detection system to minimize the false alarm rate. The muzzle flash sensor developed in this work operates in real-time and has a field of view of approximately 29° (horizontal) by 12° (vertical) with a pixel resolution of 0.13°. The work has demonstrated that extension to a sensor with realistic angular rotation rate is feasible.

Top