Sample records for fish screening devices

  1. Field-based evaluations of horizontal flat-plate fish screens, II: Testing of a unique off-stream channel device - The Farmers Screen

    USGS Publications Warehouse

    Mesa, Matthew G.; Rose, Brien P.; Copeland, Elizabeth S.

    2012-01-01

    Screens are installed at water diversion sites to reduce entrainment of fish. Recently, the Farmers Irrigation District (Oregon) developed a unique flat-plate screen (the “Farmers Screen”) that operates passively and may offer reduced installation and operating costs. To evaluate the effectiveness of this screen on fish, we conducted two separate field experiments. First, juvenile coho salmon Oncorhynchus kisutch were released over a working version of this screen under a range of inflows (0.02–0.42 m3/s) and diversion flows (0.02–0.34 m3/s) at different water depths. Mean approach velocities ranged from 0 to 5 cm/s and sweeping velocities ranged from 36 to 178 cm/s. Water depths over the screen surface ranged from 1 to 25 cm and were directly related to inflow. Passage of fish over the screen under these conditions did not severely injure them or cause delayed mortality, and no fish were observed becoming impinged on the screen surface. Second, juvenile coho salmon and steelhead O. mykiss were released at the upstream end of a 34-m flume and allowed to volitionally move downstream and pass over a 3.5-m section of the Farmers Screen to determine whether fish would refuse to pass over the screen after encountering its leading edge. For coho salmon, 75–95% of the fish passed over the screen within 5 min and 82–98% passed within 20 min, depending on hydraulic conditions. For steelhead, 47–90% of the fish passed over the screen within 5 min and 79–95% passed within 20 min. Our results indicate that when operated within its design criteria, the Farmers Screen provides safe and efficient downstream passage of juvenile salmonids under a variety of hydraulic conditions.

  2. Fish-protection devices at unscreened water diversions can reduce entrainment: evidence from behavioural laboratory investigations

    PubMed Central

    Poletto, Jamilynn B.; Cocherell, Dennis E.; Mussen, Timothy D.; Ercan, Ali; Bandeh, Hossein; Kavvas, M. Levent; Cech, Joseph J.; Fangue, Nann A.

    2015-01-01

    Diversion (i.e. extraction) of water from rivers and estuaries can potentially affect native wildlife populations if operation is not carefully managed. For example, open, unmodified water diversions can act as a source of injury or mortality to resident or migratory fishes from entrainment and impingement, and can cause habitat degradation and fragmentation. Fish-protection devices, such as exclusion screens, louvres or sensory deterrents, can physically or behaviourally deter fish from approaching or being entrained into water diversions. However, empirical assessment of their efficacy is often lacking or is investigated only for particular economically or culturally important fishes, such as salmonids. The Southern population of anadromous green sturgeon (Acipenser medirostris) is listed as threatened in California, and there is a high density of water diversions located within their native range (the Sacramento–San Joaquin watershed). Coupled with their unique physiology and behaviour compared with many other fishes native to California, the green sturgeon is susceptible to entrainment into diversions and is an ideal species with which to study the efficacy of mitigation techniques. Therefore, we investigated juvenile green sturgeon (188–202 days post-hatch) in the presence of several fish-protection devices to assess behaviour and entrainment risk. Using a large experimental flume (∼500 kl), we found that compared with an open diversion pipe (control), the addition of a trash-rack box, louvre box, or perforated cylinder on the pipe inlet all significantly reduced the proportion of fish that were entrained through the pipe (P = 0.03, P = 0.028, and P = 0.028, respectively). Likewise, these devices decreased entrainment risk during a single movement past the pipe by between 60 and 96%. These fish-protection devices should decrease the risk of fish entrainment during water-diversion activities. PMID:27293725

  3. Washington Phase II Fish Diversion Screen Evaluations in the Yakima and Touchet River Basins, 2005-2006 Annual Reports.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chamness, Mickie; Abernethy, C.; Tunnicliffe, Cherylyn

    2006-02-01

    In 2005, Pacific Northwest National Laboratory (PNNL) researchers evaluated 25 Phase II fish screen sites in the Yakima and Touchet river basins. Pacific Northwest National Laboratory performs these evaluations for Bonneville Power Administration (BPA) to determine whether the fish screening devices meet National Marine Fisheries Service (NMFS) criteria to promote safe and timely fish passage. Evaluations consist of measuring velocities in front of the screens, using an underwater camera to look at the condition and environment in front of the screens, and noting the general condition and operation of the sites. Results of the evaluations in 2005 include the following:more » (1) Most approach velocities met the NMFS criterion of less than or equal to 0.4 fps. Less than 13% of all approach measurements exceeded the criterion, and these occurred at 10 of the sites. Flat-plate screens had more problems than drum screens with high approach velocities. (2) Bypass velocities generally were greater than sweep velocities, but sweep velocities often did not increase toward the bypass. The latter condition could slow migration of fish through the facility. (3) Screen and seal materials generally were in good condition. (4) Automated cleaning brushes generally functioned properly; chains and other moving parts were typically well-greased and operative. (5) Washington Department of Fish and Wildlife (WDFW) and U.S. Bureau of Reclamation (USBR) generally operate and maintain fish screen facilities in a way that provides safe passage for juvenile fish. (6) In some instances, irrigators responsible for specific maintenance at their sites (e.g., debris removal) are not performing their tasks in a way that provides optimum operation of the fish screen facility. New ways need to be found to encourage them to maintain their facilities properly. (7) We recommend placing datasheets providing up-to-date operating criteria and design flows in each sites logbox. The datasheet should include bypass design flows and a table showing depths of water over the weir and corresponding bypass flow. This information is available at some of the sites but may be outdated. These data are used to determine if the site is running within design criteria. (8) Modifying use of debris control plates at Gleed helped minimize the extreme fluctuations in flow, but approach velocities are still too high. Other ways to reduce the approach velocities need to be tried, possibly including redesign of the site. (9) Alternatives to a screen site at Taylor should be considered. A lot of effort was spent trying to increase water to the site, but it still was unable to operate within NMFS criteria for most of the year and may be a hazard to juvenile salmonids. We conclude that the conditions at most of the Phase II fish screen facilities we evaluated in 2005 would be expected to provide safe passage for juvenile fish. For those sites where conditions are not always optimum for safe fish passage, PNNL researchers will try to coordinate with the WDFW and USBR in 2006 to find solutions to the problems. Some of those problems are consistently high approach velocities at specific sites, including Congdon, Naches-Selah, Union Gap, and Yakima-Tieton. We would like to be able to monitor changes in velocities as soon as operations and maintenance personnel adjust the louvers or porosity boards at these sites. This will give them immediate feedback on the results of their modifications and allow additional adjustments as necessary until the conditions meet NMFS criteria. Pacific Northwest National Laboratory has performed evaluations at many of these sites over the past 8 years, providing information WDFW and USBR personnel can use to perform their operations and maintenance more effectively. Consequently, overall effectiveness of the screens facilities has improved over time.« less

  4. OpenSource lab-on-a-chip physiometer for accelerated zebrafish embryo biotests.

    PubMed

    Akagi, Jin; Hall, Chris J; Crosier, Kathryn E; Cooper, Jonathan M; Crosier, Philip S; Wlodkowic, Donald

    2014-01-02

    Zebrafish (Danio rerio) embryo assays have recently come into the spotlight as convenient experimental models in both biomedicine and ecotoxicology. As a small aquatic model organism, zebrafish embryo assays allow for rapid physiological, embryo-, and genotoxic tests of drugs and environmental toxins that can be simply dissolved in water. This protocol describes prototyping and application of an innovative, miniaturized, and polymeric chip-based device capable of immobilizing a large number of living fish embryos for real-time and/or time-lapse microscopic examination. The device provides a physical address designation to each embryo during analysis, continuous perfusion of medium, and post-analysis specimen recovery. Miniaturized embryo array is a new concept of immobilization and real-time drug perfusion of multiple individual and developing zebrafish embryos inside the mesofluidic device. The OpenSource device presented in this protocol is particularly suitable to perform accelerated fish embryo biotests in ecotoxicology and phenotype-based pharmaceutical screening. Copyright © 2014 John Wiley & Sons, Inc.

  5. Effectiveness of common fish screen materials to protect lamprey ammocoetes

    USGS Publications Warehouse

    Rose, Brien P.; Mesa, Matthew G.

    2012-01-01

    Understanding the effects of irrigation diversions on populations of Pacific lampreyLampetra tridentata in the Columbia River basin is needed for their recovery. We tested the effectiveness of five common fish screen materials for excluding lamprey ammocoetes: interlock (IL), vertical bar (VB), perforated plate (PP), and 12-gauge and 14-gauge wire cloth (WC12) and (WC14). When fish (28–153 mm) were exposed for 60 min to screen panels perpendicular to an approach velocity of 12 cm/s in a recirculating flume, the percentage of ammocoetes entrained (i.e., passed through the screen) was 26% for the IL, 18% for the PP, 33% for the VB, 62% for the WC14, and 65% for the WC12 screens. For all screens, most fish were entrained within the first 15–20 min. Fish length significantly influenced entrainment, with the PP, VB, and IL screens preventing fish greater than 50–65 mm from entrainment and the WC14 and WC12 screens preventing entrainment of fish greater than 90–110 mm. Fish of all sizes repeatedly became impinged (i.e., contacting the screen for more than 1 s) on the screens, with the frequency of impingement events increasing during the first 5 min and becoming relatively stable thereafter. Impingement ranges were highest on the IL screen (36–62%), lowest on the WC14 and WC12 screens (13–31%), and intermediate on the PP and VB screens (23–54%). However, the WC14 and WC12 screens had fewer and larger fish remaining as time elapsed because so many were entrained. For all screen types, injuries were rare and minor, and no fish died after overnight posttest holding. Our results indicate that wire cloth screens should be replaced, where practical, with perforated plate, vertical bar, or interlocking bar screens to reduce lamprey entrainment at water diversions.

  6. Investigation of Organic Chemicals Potentially Responsible for Mortality and Intersex in Fish of the North Fork of the Shenandoah River, Virginia, during Spring of 2007

    USGS Publications Warehouse

    Alvarez, David A.; Cranor, Walter L.; Perkins, Stephanie D.; Schroeder, Vickie L.; Werner, Stephen; Furlong, Edward T.; Holmes, John

    2008-01-01

    Declining fish health, fish exhibiting external lesions, incidences of intersex, and death, have been observed recently within the Potomac River basin. The basin receives surface runoff and direct inputs from agricultural, industrial, and other human activities. Two locations on the North Fork of the Shenandoah River were selected for study in an attempt to identify chemicals that may have contributed to the declining fish health. Two passive sampling devices, semipermeable membrane devices (SPMDs) and polar organic chemical integrative samplers (POCIS), were deployed during consecutive two-month periods during the spring and early summer of 2007 to measure select organic contaminants to which fish may have been exposed. This study determined that concentrations of persistent hydrophobic contaminants, such as polycyclic aromatic hydrocarbons (< picograms per liter), legacy pesticides (<10 picograms per liter), and polychlorinated biphenyls (<280 picograms per liter) were low and indicative of a largely agricultural area. Atrazine and simazine were the most commonly detected pesticides. Atrazine concentrations ranged from 68 to 170 nanograms per liter for the March to April study period and 320 to 650 nanograms per liter for the April to June study period. Few chemicals characteristic of wastewater treatment plant effluent or septic tank discharges were identified. In contrast, para-cresol, N,N-diethyltoluamide, and caffeine commonly were detected. Prescription pharmaceuticals including carbamazepine, venlafaxine, and 17a-ethynylestradiol were at low concentrations. Extracts from the passive samplers also were screened for the presence of estrogenic chemicals using the yeast estrogen screen. An estrogenic response was observed in POCIS samples from both sites, whereas SPMD samples exhibited little to no estrogenicity. This indicates that the chemicals producing the estrogenic response have a greater water solubility and are, therefore, less likely to bioaccumulate in fatty tissues of organisms.

  7. Walla Walla River Basin Fish Screen Evaluations; Nursery Bridge Fishway, Garden City/Lowden II, and Little Walla Walla Sites, 2004 Annual Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vucelick, J.; McMichael, G.

    2004-11-01

    Pacific Northwest National Laboratory evaluated the fish screens at the Nursery Bridge Fishway, the Garden City/Lowden II site west of Walla Walla, Washington, and the Little Walla Walla site in Milton-Freewater, Oregon, in the Walla Walla River Basin during 2004. The fish-screen facilities were examined to determine if they were being effectively operated and maintained to provide for safe fish passage. At the Nursery Bridge Fishway, the screens were evaluated specifically to determine whether the louvers that aid in controlling water flow from behind the screens could be adjusted so that the screens would meet fish-protection criteria. Data were collectedmore » to determine whether velocities in front of the screens met current National Oceanic and Atmospheric Administration's National Marine Fisheries Service (NOAA Fisheries) (formerly NMFS) criteria to promote safe and timely fish passage before and after changing the louver settings. The Little Walla Walla screens were evaluated to determine how a build-up of algae on the screens affected water velocities.« less

  8. Field-based evaluations of horizontal flat-plate fish screens

    USGS Publications Warehouse

    Rose, B.P.; Mesa, M.G.; Barbin-Zydlewski, G.

    2008-01-01

    Diversions from streams are often screened to prevent the loss of or injury to fish. Hydraulic criteria meant to protect fish that encounter screens have been developed, but primarily for screens that are vertical to the water flow rather than horizontal. For this reason, we measured selected hydraulic variables and released wild rainbow trout Oncorhynchus mykiss over two types of horizontal flat-plate fish screens in the field. Our goal was to assess the efficacy of these screens under a variety of conditions in the field and provide information that could be used to develop criteria for safe fish passage. We evaluated three different invertedweir screens over a range of stream (0.24-1.77 m3/s) and diversion flows (0.10-0.31 m3/s). Approach velocities (AVs) ranged from 3 to 8 cm/s and sweeping velocities (SVs) from 69 to 143 cm/s. We also evaluated a simple backwatered screen over stream flows of 0.23-0.79 m3/s and diversion flows of 0.08-0.32 m3/s. The mean SVs for this screen ranged from 15 to 66 cm/s and the mean AVs from 1 to 5 cm/s. The survival rates of fish held for 24 h after passage over these screens exceeded 98%. Overall, the number of fish-screen contacts was low and the injuries related to passage were infrequent and consisted primarily of minor fin injuries. Our results indicate that screens of this type have great potential as safe and effective fish screens for small diversions. Care must be taken, however, to avoid operating conditions that produce shallow or no water over the screen surface, situations of high AVs and low SVs at backwatered screens, and situations producing a localized high AV with spiraling flow. ?? Copyright by the American Fisheries Society 2008.

  9. 14. Charles Acey Cobb standing adjacent to the fish screen ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. Charles Acey Cobb standing adjacent to the fish screen he designed and installed in the Congdon Canal, facing southeast. Photo dates ca. late 1920's. - Congdon Canal, Fish Screen, Naches River, Yakima, Yakima County, WA

  10. Fish freshness detection by a computer screen photoassisted based gas sensor array.

    PubMed

    Alimelli, Adriano; Pennazza, Giorgio; Santonico, Marco; Paolesse, Roberto; Filippini, Daniel; D'Amico, Arnaldo; Lundström, Ingemar; Di Natale, Corrado

    2007-01-23

    In the last years a large number of different measurement methodologies were applied to measure the freshness of fishes. Among them the connection between freshness and headspace composition has been considered by gas chromatographic analysis and from the last two decades by a number of sensors and biosensors aimed at measuring some characteristic indicators (usually amines). More recently also the so-called artificial olfaction systems gathering together many non-specific sensors have shown a certain capability to transduce the global composition of the fish headspace capturing the differences between fresh and spoiled products. One of the main objectives related to the introduction of sensor systems with respect to the analytical methods is the claimed possibility to distribute the freshness control since sensors are expected to be "portable" and "simple". In spite of these objectives, until now sensor systems did not result in any tool that may be broadly distributed. In this paper, we present a chemical sensor array where the optical features of layers of chemicals, sensitive to volatile compounds typical of spoilage processes in fish, are interrogated by a very simple platform based on a computer screen and a web cam. An array of metalloporphyrins is here used to classify fillets of thawed fishes according to their storage days and to monitor the spoilage in filleted anchovies for a time of 8 h. Results indicate a complete identification of the storage days of thawed fillets and a determination of the storage time of anchovies held at room temperature with a root mean square error of validation of about 30 min. The optical system produces a sort of spectral fingerprint containing information about both the absorbance and the emission of the sensitive layer. The system here illustrated, based on computer peripherals, can be easily scaled to any device endowed with a programmable screen and a camera such as cellular phones offering for the first time the possibility to fulfil the sensor expectation of diffused and efficient analytical capabilities.

  11. Biological Evaluations of an Off-Stream Channel, Horizontal Flat-Plate Fish Screen-The Farmers Screen

    USGS Publications Warehouse

    Mesa, Matthew G.; Rose, Brien P.; Copeland, Elizabeth S.

    2010-01-01

    Screens are commonly installed at water diversion sites to reduce entrainment of fish. Recently, the Farmers Irrigation District in Hood River, Oregon, developed a new flat-plate screen design that offers passive operation and may result in reduced operation and installation costs to irrigators. To evaluate the performance (its biological effect on fish) of this type of screen, two size classes of juvenile coho salmon (Oncorhynchus kistuch) were released over a small version of this screen in the field-the Herman Creek screen. The performance of the screen was evaluated over a range of inflow [0.02 to 0.42 m3/s (cubic meters per second)] and diversion flows (0.02 to 0.34 m3/s) at different weir wall heights. The mean approach velocities for the screen ranged from 0 to 5 cm/s (centimeters per second) and mean sweeping velocities ranged from 36 to 178 cm/s. Water depths over the screen surface ranged from 1 to 25 centimeters and were directly related to weir wall height and inflow. Passage of juvenile coho salmon over the screen under a variety of hydraulic conditions did not severely injure them or cause delayed mortality. For all fish, the mean percentage of body surface area that was injured after passage over the screen ranged from about 0.4 to 3.0%. This occurred even though many fish contacted the screen surface during passage. No fish were observed becoming impinged on the screen surface (greater than 1 second contact with the screen). When operated within its design criteria (diversion flows of about 0.28 m3/s), the screen provided safe and effective downstream passage of juvenile salmonids under a variety of hydraulic conditions. However, we do not recommend operating the screen at inflows less than 0.14 m3/s (5 ft3/s) because water depth can get quite shallow and the screen can completely dewater, particularly at very low flows.

  12. Walla Walla River Basin Fish Screen Evaluations; Nursery Bridge Fishway and Garden City/Lowden II Sites, 2003 Technical Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vucelick, J.; McMichael, G.

    2003-11-01

    Pacific Northwest National Laboratory evaluated the fish screens at the Nursery Bridge Fishway and the newly constructed Garden City/Lowden II site west of Walla Walla, Washington, in the Walla Walla River Basin during spring and summer 2003. Both fish screen facilities were examined to determine if they were being effectively operated and maintained to provide for safe fish passage. At the Nursery Bridge Fishway, the screens were evaluated specifically to determine whether the louvers that aid in controlling water flow from behind the screens could be adjusted so that the screens would meet fish protection criteria. Data were collected tomore » determine whether velocities in front of the screens and in the bypasses met current National Oceanic and Atmospheric Administration Fisheries (NOAA Fisheries) (formerly National Marine Fisheries Service (NMFS)) criteria to promote safe and timely fish passage before and after changing the louver settings. Rock weirs downstream of the dam were also evaluated to determine whether they might impede upstream migration of juvenile salmonids during low flow conditions. At the Garden City/Lowden II site, data were collected to establish a baseline for operating conditions and to determine whether any changes in the baffle settings were needed.« less

  13. 1. FIRST SECTION OF PIPELINE BETWEEN CONFLUENCE POOL AND FISH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. FIRST SECTION OF PIPELINE BETWEEN CONFLUENCE POOL AND FISH SCREEN. NOTE RETAINING WALL BESIDE PIPE. VIEW TO NORTH-NORTHEAST. - Santa Ana River Hydroelectric System, Pipeline to Fish Screen, Redlands, San Bernardino County, CA

  14. 15. CYLINDRICAL FISH SCALER Remnants of the wire screen remain, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. CYLINDRICAL FISH SCALER Remnants of the wire screen remain, through which the fish tumbled as the cylinder revolved. Note geared ring around cylinder, and the small drive shaft by which it was driven. - Hovden Cannery, 886 Cannery Row, Monterey, Monterey County, CA

  15. Efficacy of a novel procedure sheath and closure device during diagnostic catheterization: the multicenter randomized clinical trial of the FISH device.

    PubMed

    Bavry, Anthony A; Raymond, Russell E; Bhatt, Deepak L; Chambers, Charles E; DeNardo, Andrew J; Hermiller, James B; Myers, Paul R; Pitts, Douglas E; Scott, John A; Savader, Scott J; Steinhubl, Steven

    2008-04-01

    The aim of vascular closure devices is to safely secure the arterial access site at the conclusion of catheterization procedures, thereby increasing patient comfort and decreasing time to hemostasis and ambulation. The FISH (femoral introducer sheath and hemostasis) device is novel in that the access sheath and closure component are incorporated onto the same system. The FISH pivotal investigation was conducted at 8 catheterization laboratories throughout the United States. Eligible diagnostic patients were randomized (2 to 1) to the FISH device versus manual compression and assessed for time to hemostasis and time to ambulation. Half of the participants underwent ultrasonographic evaluation at 30-day follow up. Enrollment for an interventional cohort is ongoing and will be reported at a later date; however, the interventional patients enrolled to date were combined with the diagnostic patients to comprise the safety data of the trial. Overall, 191 patients were randomized to the FISH device and 106 patients to manual compression. Most patients received a 6 Fr sheath (approximately 70%), while the remaining patients received a 5 or 8 Fr sheath. Twenty-seven patients who received the FISH device were converted to manual compression due to anticipated suboptimal hemostasis. Among the diagnostic patients, the mean time to hemostasis was 8.9 minutes for the FISH device, compared to 17.2 minutes for manual compression (p < 0.0001). Similarly, the mean time to ambulation was 2.4 hours for the FISH device, compared to 4.3 hours for manual compression (p < 0.0001). Among the total cohort, there was 1 death and 1 episode of major access-site-related bleeding that required transfusion occurred in the FISH group (1.1%), compared to no serious adverse safety events in the manual compression group (p = 1.0). For the FISH group, there were 5 minor adverse safety events; 3 access-site hematomas and 2 pseudoaneurysms treated with thrombin injection, and in the manual compression group, there was 2 access-site hematomas and 1 pseudoaneurysm treated with thrombin injection (p = 1.0). Among diagnostic patients with good sheath placement and favorable femoral anatomy, the FISH device is superior in achieving time to hemostasis and ambulation compared to manual compression. At 30 days, there is no apparent difference in serious or minor adverse vascular events with the use of the FISH device.

  16. PROTOTYPE EICHER FISH SCREEN AND EVALUATION FACILITY, INSTALLED IN 1990 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PROTOTYPE EICHER FISH SCREEN AND EVALUATION FACILITY, INSTALLED IN 1990 ON #1 PENSTOCK. PROJECT SPONSORED BY THE ELECTRICAL POWER RESEARCH INSTITUTE TO TRANSFER FISH DOWNSTREAM PAST THE TURBINES. PHOTO BY JET LOWE, HAER, 1995. - Elwha River Hydroelectric System, Elwha Hydroelectric Dam & Plant, Port Angeles, Clallam County, WA

  17. Walla Walla River Basin Fish Screen Evaluations, 2003: Nursery Bridge Fishway and Garden City-Lowden II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vucelick, Jessica A.; McMichael, Geoffrey A.

    2003-11-01

    The Pacific Northwest National Laboratory (PNNL) evaluated the fish screens at the Nursery Bridge Fishway and at the newly constructed Garden City-Lowden II site west of Walla Walla, Washington in the Walla Walla River Basin during the spring and summer of 2003. Both fish screen facilities were examined to determine if they were being effectively operated and maintained to provide for safe fish passage. At the Nursery Bridge Fishway, the screens were evaluated specifically to determine whether the louvers that aid in controlling water flow from behind the screens could be adjusted so that the screens would meet fish protectionmore » criteria. Data were collected to determine whether velocities in front of the screens and in the bypasses met current National Oceanic and Atmospheric Administration Fisheries ((NOAA Fisheries), formerly National Marine Fisheries Service (NMFS)) criteria to promote safe and timely fish passage before and after changing the louver settings. Rock weirs downstream of the dam were also evaluated to determine whether they might impede upstream migration of juvenile salmonids during low flow conditions. At the Garden City-Lowden II site, data were collected to establish a baseline for operating conditions and to determine whether any changes in the baffle settings were needed. Based on the results of our studies in 2003, we concluded: Nursery Bridge Site: (1) 68% of the initial velocity measurements on the west screen exceeded the NOAA Fisheries criteria of 0.4 ft/s for approach velocity; (2) A simple adjustment of the existing louvers was not sufficient to fix the problem; (3) The sediment and debris load in the river upstream of the screens exceeded the design criteria for the site, which had frequent breakdowns in the screen cleaning systems; and (4) The rock weirs downstream of the dam would not be expected to impede upstream movement of juvenile fish during low flow conditions. Garden City-Lowden II: (1) The flat inclined-plate screen design appeared to be efficiently protecting juvenile fish from entrainment, impingement and migration delay; (2) Approach velocities met the NMFS criteria of less than 0.4 ft/s in June, and no change in baffle settings was needed; (3) Sweep velocities were generally lower than approach velocities and did not increase toward the downstream end of the site; and (4) The automated cleaning system at the Garden City-Lowden II site works adequately when sediment loads are low, though its effectiveness at cleaning the screens decreases as sediment and debris loads and algal growth increase.« less

  18. Reconnaissance of persistent and emerging contaminants in the Shenandoah and James River Basins, Virginia, during Spring of 2007

    USGS Publications Warehouse

    Alvarez, David A.; Cranor, Walter; Perkins, Stephanie D.; Schroeder, Vickie; Werner, Stephen; Furlong, Edward; Kain, Donald; Brent, Robert

    2008-01-01

    Fish exhibiting external lesions, incidences of intersex, and death have recently been observed in the Shenandoah and James River Basins. These basins are characterized by widespread agriculture (intensive in some areas), several major industrial discharges, numerous sewage treatment plant discharges, and urban, transportation, and residential growth that has increased rapidly in recent years. Nine locations in the Shenandoah River Basin, Virginia, and two in the James River Basin, Virginia, were selected for study in an attempt to identify chemicals that may have contributed to the declining fish health. Two passive sampling devices, semipermeable membrane devices (SPMDs) and polar organic chemical integrative samplers (POCIS), were deployed during the spring and early summer of 2007 to measure select organic contaminants to which fish may have been exposed. This study determined that concentrations of persistent hydrophobic contaminants, such as polycyclic aromatic hydrocarbons (<17,000 picograms per liter), legacy pesticides (<510 picograms per liter), and polychlorinated biphenyls (<1,600 picograms per liter) were generally low and indicative of a largely agricultural area. Chlorpyrifos, endosulfan, and lindane were the most commonly detected chlorinated pesticides. Atrazine, which was detected at concentrations much greater than other pesticides associated with agricultural use, ranged from <0.18 to 430 nanograms per liter during the deployment period. Few chemicals characteristic of wastewater treatment plant effluent or septic tank discharges were detected. The fragrance components, galaxolide, indole, and tonalide, were the predominant waste indicator chemicals detected. Caffeine, the caffeine metabolite 1,7-dimethylxanthine, the nicotine metabolite cotinine, and the prescription pharmaceuticals carbamazepine, venlafaxine, and trimethoprim were detected at several sites. Natural and synthetic hormones were detected at a few sites with 17α-ethynylestradiol concentrations esimated up to 8.1 nanograms per liter. Screening of the POCIS extracts for estrogenic chemicals by using the yeast estrogen screen revealed estrogenicity similar to levels reported for rural areas with minor effect from wastewater effluents.

  19. Fish Behavior, Presence, and Distribution in a Tidally Dynamic Region, with and without a Tidal Energy Device

    NASA Astrophysics Data System (ADS)

    Zydlewski, G. B.; Staines, G.; Viehman, H.; Shen, H.

    2016-02-01

    Fish responses, presence, and use of tidally dynamic regions are not well documented. Baseline and effect data were collected to examine responses of fish to the introduction of a tidal power device. In 2012 Ocean Renewable Power Company's TidGen® was deployed for one year and in 2014 their OCGen® was deployed for 2.5 months. We used this opportunity to determine (1) the vertical distribution of fishes before and after device deployment; (2) how fish behaved when approaching a device; and (3) the probability of fish encountering a device. From 2010 to 2013, 21 twenty-four-hour down-looking hydroacoustic surveys were performed at a project and control site. Prior to deployment (2010-2012) fish were generally distributed near the sea floor and more evenly distributed in the water column at night than during the day and there were significant differences between two of three before/after comparisons of vertical fish distributions, indicating an effect of the device. DIDSON acoustic cameras were used to document behavioral responses to a device. Most fish observed were <10 cm and moved in the same direction as the current. Approximately 50% of individuals and 67% of schools did not interact with the turbine. Less than 1% of individuals and 15% of schools showed avoidance behavior, and 35% of individuals and 14% of schools entered or exited the turbine. Turbine rotation reduced the probability of turbine entry by 35% and increased the probability of avoiding and passing by 120% and 97%, respectively. In 2014 we combined down-looking hydroacoustics with mobile transects to determine that the probability of fish being at the depth of the moving foils ( 6-9 m) ranged from 0.083 to 0.093. These data indicate how fish respond to this novel object and are important for understanding fish use of such a dynamic ecosystem.

  20. FISH and tips: a large scale analysis of automated versus manual scoring for sperm aneuploidy detection.

    PubMed

    Martinez, Guillaume; Gillois, Pierre; Le Mitouard, Marine; Borye, Rémy; Esquerré-Lamare, Camille; Satre, Véronique; Bujan, Louis; Hennebicq, Sylviane

    2013-01-01

    Approximately 1% of the spermatozoa found in ejaculate of healthy men are aneuploid and this rate increases in the population of subfertile and infertile men. Moreover, fertilization with these aneuploid sperm can lead to impaired embryo development. Fluorescent In Situ Hybridization (FISH) is the common cytogenetic tool used for aneuploidy screening on sperm. However, it is a time-consuming technique and cytogenetic or in vitro fertilization laboratories cannot routinely use it and face the increasing demand of such analyses before Assisted Reproductive Techniques (ART). As automation can be a clue for routine practice, this study compares manual and automated scoring of sperm aneuploidy rates using a Metafer Metasystems® device. The results obtained also contribute to global data about FISH on sperm cells. We recruited 100 men addressed for sperm cryopreservation. They all signed an informed consent to participate in the study. 29 men were donors or consulted before vasectomy (control group) and 71 were suffering of Hodgkin's disease or non Hodgkin lymphoma (patient group). One semen sample was collected for each patient, analyzed according to WHO criteria and prepared for a triple-color FISH using centromeric probes for chromosomes 18, X and Y. Automated scoring was performed using a Metafer Metasystems® device. 507,019 cells were scored. We found a strong concordance between the automated and the manual reading (d < 0.01 in Bland-Altman test). We also did not find a statistically significant difference between the automated and the manual reading using Wilcoxon test for total aneuploidy rate (p = 0.06), sex chromosomes disomy (p = 0.33), chromosome 18 disomy (p = 0.39) and diploidy (p = 0.21). Cumulative rate of total aneuploidy was 0.78% ± 0.212% for patient group and 0.54% ± 0.15 for control group and among this, sex chromosome XY disomy rate was of 0.54% for patient group and 0.27% for control group. This study validates the automated reading for FISH on sperm with a Metafer Metasystems® device and allows its use in a laboratory routine.

  1. A Method for Measuring Fishing Effort by Small-Scale Fish Aggregating Device (FAD) Fishers from the Commonwealth of Dominica

    ERIC Educational Resources Information Center

    Alvard, Michael; McGaffey, Ethan; Carlson, David

    2015-01-01

    We used global positioning system (GPS) technology and tracking analysis to measure fishing effort by marine, small-scale, fish aggregating device (FAD) fishers of the Commonwealth of Dominica. FADs are human-made structures designed to float on the surface of the water and attract fish. They are also prone to common pool resource problems. To…

  2. Effectiveness of common fish screen materials for protecting lamprey ammocoetes—Influence of sweeping velocities and decreasing flows

    USGS Publications Warehouse

    Mesa, Matthew G.; Liedtke, Theresa L.; Weiland, Lisa K.; Christiansen, Helena E.

    2017-12-14

    In previous tests of the effectiveness of four common fish screen materials for excluding lamprey ammocoetes, we determined that woven wire (WW) allowed substantially more entrainment than perforated plate (PP), profile bar (PB), or Intralox (IL) material. These tests were simplistic because they used small vertically-oriented screens positioned perpendicular to the flow without a bypass or a sweeping velocity (SV). In the subsequent test discussed in this report, we exposed ammocoetes to much larger (2.5-m-wide) screen panels with flows up to 10 ft3 /s, a SV component, and a simulated bypass channel. The addition of a SV modestly improved protection of lamprey ammocoetes for all materials tested. A SV of 35 cm/s with an approach velocity (AV) of 12 cm/s, was able to provide protection for fish about 5–15 mm smaller than the protection provided by an AV of 12 cm/s without a SV component. The best-performing screen panels (PP, IL, and PB) provided nearly complete protection from entrainment for fish greater than 50-mm toal length, but the larger openings in the WW material only protected fish greater than 100-mm total length. Decreasing the AV and SV by 50 percent expanded the size range of protected lampreys by about 10–15 mm for those exposed to IL and WW screens, and it decreased the protective ability of PP screens by about 10 mm. Much of the improvement for IL and WW screens under the reduced flow conditions resulted from an increase in the number of lampreys swimming away from the screen. Fish of all sizes became impinged (that is, stuck on the screen surface for more than 1 s) on the screens, with the rate of impingement highest on PP (39– 72 percent) and lowest on WW (7–22 percent). Although impingements were common, injuries were rare, and 24-h post-test survival was greater than 99 percent. Our results refined the level of protection provided by these screen materials when both an AV and SV are present and confirmed our earlier recommendation that WW screens be replaced with more effective materials. Future work should focus on determining the risks associated with other screen types (for example, rotary drum screens, horizontal flat plate screens) and exploring the effectiveness of higher SV:AV ratios, because it may help expand the range of sizes protected by the best performing materials.

  3. Walla Walla River Basin Fish Screen Evaluations; Nursery Bridge Fishway and Garden City/Lowden II Sites, 2005-2006 Progress Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chamness, Mickie

    2006-06-01

    Pacific Northwest National Laboratory (PNNL) evaluated two fish screen facilities in the Walla Walla River basin in 2005 and early 2006. The Garden City/Lowden screen site was evaluated in April and June 2005 to determine whether the fish screens met National Marine Fisheries Service criteria to provide safe passage for juvenile salmonids. Louvers behind the screens at the Nursery Bridge Fishway were modified in fall 2005 in an attempt to minimize high approach velocities. PNNL evaluated the effects of those modifications in March 2006. Results of the Garden City/Lowden evaluations indicate the site performs well at varying river levels andmore » canal flows. Approach velocities did not exceed 0.4 feet per second (fps) at any time. Sweep velocities increased toward the fish ladder in March but not in June. The air-burst mechanism appears to keep large debris off the screens, although it does not prevent algae and periphyton from growing on the screen face, especially near the bottom of the screens. At Nursery Bridge, results indicate all the approach velocities were below 0.4 fps under the moderate river levels and operational conditions encountered on March 7, 2006. Sweep did not consistently increase toward the fish ladder, but the site generally met the criteria for safe passage of juvenile salmonids. Modifications to the louvers seem to allow more control over the amount of water moving through the screens. We will measure approach velocities when river levels are higher to determine whether the louver modifications can help correct excessive approach velocities under a range of river levels and auxiliary water supply flows.« less

  4. 2. PLANK WALKWAY ATOP PIPE, ALSO SHOWING OVERFLOW CONTROL BOX ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. PLANK WALKWAY ATOP PIPE, ALSO SHOWING OVERFLOW CONTROL BOX AT JUNCTION OF PIPE WITH CONCRETE CHANNEL TO FISH SCREEN. VIEW TO NORTHEAST. - Santa Ana River Hydroelectric System, Pipeline to Fish Screen, Redlands, San Bernardino County, CA

  5. Interactions of aquatic animals with the ORPC OCGen® in Cobscook Bay, Maine: Monitoring behavior change and assessing the probability of encounter with a deployed MHK device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zydlewski, Gayle Barbin; Staines, Garrett; Viehman, Haley

    Commercial viability of the marine hydrokinetic (MHK) energy industry is contingent on numerous and diverse factors. A major factor is the effects deployed devices have on animals. This factor is multi-faceted since it is dependent on the availability of appropriate scientific approaches to detect these effects. One of the animal groups with overlapping distributions of MHK devices are fishes. As such, individual fish behavior is likely to be influenced by the presence and operation of MHK devices. Depending on the scale of deployment there are implications for changes to essential fish habitat and effects that can be explored during deploymentmore » of a single device yet most changes are likely to be realized when multiple devices are deployed over large areas. It is not only important to document these effects and examine the need for mitigation, but also determine whether the methods involved can be used within the economic constraints of this nascent industry. The results presented in this report benefit the MHK industry by providing transferrable environmental monitoring approaches for MHK projects, specifically related to the interactions between static and dynamic tidal turbines and fish. In addition, some of the data can be used to generalize conditions (e.g., the temporal periodicity of fish presence in tidal regions and probability of fish encountering a device) at other MHK sites with similar physical conditions and fish assemblages. Ocean Renewable Power Company, LLC (ORPC) deployed and tested a prototype OCGen® tidal module in Cobscook Bay, Maine, in the summer of 2014. University of Maine researchers proposed an approach to inform other researchers, regulators, and industry members of the effects of this deployment on fish. While the approach was specifically applied to the OCGen® module, results are applicable to other pilot projects and inform future array deployments. Research funded under this grant allowed us to quantify fish presence as well as individual and group-level behavior changes in the presence of the deployed OCGen® module along with a bottom support frame from a previously deployed device (TidGen®). Specific objectives associated with fish behavior changes were (1) continuation of two long-term datasets: (a) stationary down-looking hydroacoustic dataset near an MHK device (group-level) and (b) stationary side-looking hydroacoustics near the bottom-support frame of a previously deployed MHK device (individual-level); (2) application of new processing methods to down-looking hydroacoustic datasets to improve fish species identification (group-level); and (3) development of an encounter probability model using data on fish abundance, vertical distribution, and behavior.« less

  6. Circulating water traveling screen modifications to improve impinged fish survival and debris handling at Salem Generating Station

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ronafalvy, J.P.; Cheesman, R.R.; Matejek, W.M.

    This paper summarizes modifications made to the Salem Generating Station`s (Salem) Circulating Water Traveling Screens (CWTS) as required by Salem`s New Jersey Pollutant Discharge Elimination System Permit (NJPDES Permit). The modifications incorporated newly designed CWTS baskets with hydrodynamically improved fish buckets (greatly reduced turbulence in the bucket); smooth woven mesh screens with 0.250 x 0.500 inch rectangular mesh openings (formerly 0.375 inch square mesh openings); lighter composite basket frame material allowing increased screen rotation speed; improved low and high pressure spray wash patterns; improved screen to sluice trough flap seal design and miscellaneous reliability improvements. In order to address themore » overall effects of the CWTS modifications on fish losses, the effect of both entrainment and impingement by fish size was addressed in a comparison study between modified and unmodified units. The results of the assessment indicate a 51% reduction in overall weakfish (Cynoscion regales) losses (expressed as equivalent adults, larger than 187 mm total length individuals). These modifications also enhanced debris removal capability of the CWTSs. 5 refs., 5 figs.« less

  7. The Influence of Fish Length on Tissue Mercury Dynamics: Implications for Natural Resource Management and Human Health Risk

    PubMed Central

    Sackett, Dana K.; Cope, W. Gregory; Rice, James A.; Aday, D. Derek

    2013-01-01

    Consumption of fish has well-known human health benefits, though some fish may contain elevated levels of mercury (Hg) that are especially harmful to developing children. Fish length is most often the basis for establishing fishery harvest regulations that determine which fish will ultimately be consumed by humans. It is, therefore, essential to quantify the relationship between fish length and Hg accumulation in regard to harvest regulations for effective fishery and public health policy. We examined this relationship for three sportfish from six lakes across North Carolina, USA. Bluegill (Lepomis macrochirus) had the lowest Hg levels and only the very largest fish in the most contaminated site exceeded the US Environmental Protection Agency (USEPA) Hg screening level. Black crappie (Pomoxis nigromaculatus) had an intermediate level of Hg and larger individuals exceeded the USEPA screening level; however, they tended not to exceed this level before reaching the harvest length limit. Largemouth bass (Micropterus salmoides) exceeded the USEPA screening level at sizes below the fishery length limit in two lakes, leaving only higher risk fish for anglers to harvest and consume. Removing the effects of fish age and trophic position, we found strong positive correlations between Hg and fish length for largemouth bass and black crappie. We suggest public health officials and wildlife managers collaborate to structure fishery regulations and length-based fish consumption advisories that protect consumers from Hg exposure and communicate the relative risk of fish consumption. PMID:23388852

  8. Studying fish near ocean energy devices using underwater video

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matzner, Shari; Hull, Ryan E.; Harker-Klimes, Genevra EL

    The effects of energy devices on fish populations are not well-understood, and studying the interactions of fish with tidal and instream turbines is challenging. To address this problem, we have evaluated algorithms to automatically detect fish in underwater video and propose a semi-automated method for ocean and river energy device ecological monitoring. The key contributions of this work are the demonstration of a background subtraction algorithm (ViBE) that detected 87% of human-identified fish events and is suitable for use in a real-time system to reduce data volume, and the demonstration of a statistical model to classify detections as fish ormore » not fish that achieved a correct classification rate of 85% overall and 92% for detections larger than 5 pixels. Specific recommendations for underwater video acquisition to better facilitate automated processing are given. The recommendations will help energy developers put effective monitoring systems in place, and could lead to a standard approach that simplifies the monitoring effort and advances the scientific understanding of the ecological impacts of ocean and river energy devices.« less

  9. Physiological responses of adult rainbow trout experimentally released through a unique fish conveyance device

    USGS Publications Warehouse

    Mesa, Matthew G.; Gee, Lisa P.; Weiland, Lisa K.; Christiansen, Helena E.

    2013-01-01

    We assessed the physiological stress responses (i.e., plasma levels of cortisol, glucose, and lactate) of adult Rainbow Trout Oncorhynchus mykiss at selected time intervals after they had passed a distance of 15 m through a unique fish conveyance device (treatment fish) or not (controls). This device differs from traditional fish pumps in two important ways: (1) it transports objects in air, rather than pumping them from and with water; and (2) it uses a unique tube for transport that has a series of soft, deformable baffles spaced evenly apart and situated perpendicular within a rigid, but flexible outer shell. Mean concentrations of the plasma constituents never differed (P > 0.05) between control and treatment fish at 0, 1, 4, 8, or 24 h after passage, and only minor differences were apparent between the different time intervals within a group. We observed no obvious injuries on any of our fish. Our results indicate that passage through this device did not severely stress or injure fish and it may allow for the rapid and safe movement of fish at hatcheries, sorting or handling facilities, or passage obstacles.

  10. A pre-breeding screening program for transgenic boars based on fluorescence in situ hybridization assay.

    PubMed

    Bou, Gerelchimeg; Sun, Mingju; Lv, Ming; Zhu, Jiang; Li, Hui; Wang, Juan; Li, Lu; Liu, Zhongfeng; Zheng, Zhong; He, Wenteng; Kong, Qingran; Liu, Zhonghua

    2014-08-01

    For efficient transgenic herd expansion, only the transgenic animals that possess the ability to transmit transgene into next generation are considered for breeding. However, for transgenic pig, practically lacking a pre-breeding screening program, time, labor and money is always wasted to maintain non-transgenic pigs, low or null transgenic transmission pigs and the related fruitless gestations. Developing a pre-breeding screening program would make the transgenic herd expansion more economical and efficient. In this technical report, we proposed a three-step pre-breeding screening program for transgenic boars simply through combining the fluorescence in situ hybridization (FISH) assay with the common pre-breeding screening workflow. In the first step of screening, combined with general transgenic phenotype analysis, FISH is used to identify transgenic boars. In the second step of screening, combined with conventional semen test, FISH is used to detect transgenic sperm, thus to identify the individuals producing high quality semen and transgenic sperm. In the third step of screening, FISH is used to assess the in vitro fertilization embryos, thus finally to identify the individuals with the ability to produce transgenic embryos. By this three-step screening, the non-transgenic boars and boars with no ability to produce transgenic sperm or transgenic embryos would be eliminated; therefore only those boars could produce transgenic offspring are maintained and used for breeding and herd expansion. It is the first time a systematic pre-breeding screening program is proposed for transgenic pigs. This program might also be applied in other transgenic large animals, and provide an economical and efficient strategy for herd expansion.

  11. Contaminant concentrations in sport fish from San Francisco Bay, 1997.

    PubMed

    Davis, Jay A; May, Michael D; Greenfield, Ben K; Fairey, Russell; Roberts, Cassandra; Ichikawa, Gary; Stoelting, Matt S; Becker, Jonathan S; Tjeerdema, Ronald S

    2002-10-01

    In 1997, seven sport fish species were sampled from seven popular fishing areas in San Francisco Bay. Mercury exceeded a human health screening value in 44 of 84 (52%) samples. All collected samples of leopard shark and striped bass exceeded the mercury screening value of 0.23 microg/g wet weight. PCBs exceeded the screening value in 51 of 72 (71%) samples. DDT, chlordane, and dieldrin, had lower numbers of samples above screening values: 16 of 72 (22%) for DDT, 11 of 72 (15%) for chlordanes, and 27 of 72 (37%) for dieldrin. Concentrations of PCBs and other trace organics were highest in white croaker and shiner surfperch, the two species with the highest fat content in their muscle tissue. Fish from one location, Oakland Harbor, had significantly elevated wet weight concentrations of mercury, PCBs, DDTs, and chlordanes compared to other locations. Removal of skin from white croaker fillets reduced lipid concentrations by 27-49% and concentrations of trace organics by 33-40%.

  12. Impact of entrainment and impingement on fish populations in the Hudson River Estuary. Volume II. Impingement impact analyses, evaluations of alternative screening devices, and critiques of utility testimony relating to density-dependent growth, the age-composition of the striped bass spawning stock, and the LMS real-time life cycle model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnthouse, L. W.; Van Winkle, W.; Golumbek, J.

    1982-04-01

    This volume includes a series of four exhibits relating to impacts of impingement on fish populations, together with a collection of critical evaluations of testimony prepared for the utilities by their consultants. The first exhibit is a quantitative evaluation of four sources of bias (collection efficiency, reimpingement, impingement on inoperative screens, and impingement survival) affecting estimates of the number of fish killed at Hudson River power plants. The two following exhibits contain, respectively, a detailed assessment of the impact of impingement on the Hudson River white perch population and estimates of conditional impingement mortality rates for seven Hudson River fishmore » populations. The fourth exhibit is an evaluation of the engineering feasibility and potential biological effectiveness of several types of modified intake structures proposed as alternatives to cooling towers for reducing impingement impacts. The remainder of Volume II consists of critical evaluations of the utilities' empirical evidence for the existence of density-dependent growth in young-of-the-year striped bass and white perch, of their estimate of the age-composition of the striped bass spawning stock in the Hudson River, and of their use of the Lawler, Matusky, and Skelly (LMS) Real-Time Life Cycle Model to estimate the impact of entrainment and impingement on the Hudson River striped bass population.« less

  13. 37. REDUCTION PLANT DRYER Stainless steel screen cylinder, encased ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    37. REDUCTION PLANT - DRYER Stainless steel screen cylinder, encased within an outer steel shell (top half missing). As fish were tumbled by the rotating screen, they were cooked and dried by live steam piped into the dryer through overhead pipes. The dryer is mounted on a slight angle, aiding the process by moving the drying fish towards the exhaust end of the dryer. - Hovden Cannery, 886 Cannery Row, Monterey, Monterey County, CA

  14. Analyzing the cost of screening selectee and non-selectee baggage.

    PubMed

    Virta, Julie L; Jacobson, Sheldon H; Kobza, John E

    2003-10-01

    Determining how to effectively operate security devices is as important to overall system performance as developing more sensitive security devices. In light of recent federal mandates for 100% screening of all checked baggage, this research studies the trade-offs between screening only selectee checked baggage and screening both selectee and non-selectee checked baggage for a single baggage screening security device deployed at an airport. This trade-off is represented using a cost model that incorporates the cost of the baggage screening security device, the volume of checked baggage processed through the device, and the outcomes that occur when the device is used. The cost model captures the cost of deploying, maintaining, and operating a single baggage screening security device over a one-year period. The study concludes that as excess baggage screening capacity is used to screen non-selectee checked bags, the expected annual cost increases, the expected annual cost per checked bag screened decreases, and the expected annual cost per expected number of threats detected in the checked bags screened increases. These results indicate that the marginal increase in security per dollar spent is significantly lower when non-selectee checked bags are screened than when only selectee checked bags are screened.

  15. PLASMA PROTEIN PROFILING AS A HIGH THROUGHPUT TOOL FOR CHEMICAL SCREENING USING A SMALL FISH MODEL

    EPA Science Inventory

    Hudson, R. Tod, Michael J. Hemmer, Kimberly A. Salinas, Sherry S. Wilkinson, James Watts, James T. Winstead, Peggy S. Harris, Amy Kirkpatrick and Calvin C. Walker. In press. Plasma Protein Profiling as a High Throughput Tool for Chemical Screening Using a Small Fish Model (Abstra...

  16. Assignment of sockeye salmon (Oncorhynchus nerka) to spawning sites using DNA markers.

    PubMed

    Corley-Smith, Graham E; Wennerberg, Liv; Schembri, Joy A; Lim, Chinten J; Cooper, Karen L; Brandhorst, Bruce P

    2005-01-01

    Randomly amplified polymorphic DNA (RAPD) markers were used to assign individual adult sockeye salmon to their spawning sites using a genotype assignment test. Six primers were selected for use by screening bulked DNA samples for markers missing in fish from one or more of 5 sites in British Columbia or Alaska. Of 73 markers scored, 54 showed variation between or within sites among the sampled fish. Thirty-seven of the variable markers were not detected in any fish from one or more sites; 18 variable markers were detected in all fish from one or more other sites. Thus 25% of markers scored were found in all fish of some sites and in no fish of some other sites. An assignment test placed all 70 fish tested into their correct populations. Principal coordinate analysis of genetic variation produced clusters of fish corresponding to each sampling site. No sex-specific RAPD markers were detected among more than 1300 screened.

  17. 78 FR 76317 - Llano Seco Riparian Sanctuary Unit Restoration and Pumping Plant/Fish Screen Facility Protection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-17

    ...We, the U.S. Fish and Wildlife Service (Service) and the California Department of Fish and Wildlife (CDFW), announce that the record of decision (ROD) for the Llano Seco Riparian Sanctuary Unit Restoration and Princeton, Codora, Glenn & Provident Irrigation Districts (PCGID-PID) Pumping Plan/Fish Screen Facility Protection Project is now available. The ROD includes a statement of the decisions made, the basis for the decisions, a description of the alternative considered, a description of the environmentally preferable alternative, an overview of the measures to minimize environmental impacts, and a summary of public involvement in the decision-making process.

  18. Walla Walla River Basin Fish Screens Evaluations, 2006 Annual Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chamness, Mickie; Abernethy, Scott; Tunnicliffe, Cherylyn

    2007-01-01

    Pacific Northwest National Laboratory evaluated Gardena Farms, Little Walla Walla, and Garden City/Lowden II Phase II fish screen facilities and provided underwater videography beneath a leaking rubber dam in the Walla Walla River basin in 2006. Evaluations of the fish screen facilities took place in early May 2006, when juvenile salmonids are generally outmigrating. At the Gardena Farms site, extended high river levels caused accumulations of debris and sediment in the forebay. This debris covered parts of the bottom drum seals, which could lead to early deterioration of the seals and drum screen. Approach velocities were excessive at the upstreammore » corners of most of the drums, leading to 14% of the total approach velocities exceeding 0.4 feet per second (ft/s). Consequently, the approach velocities did not meet National Marine Fisheries Service (NMFS) design criteria guidelines for juvenile fish screens. The Little Walla Walla site was found to be in good condition, with all approach, sweep, and bypass velocities within NMFS criteria. Sediment buildup was minor and did not affect the effectiveness of the screens. At Garden City/Lowden II, 94% of approach velocities met NMFS criteria of 0.4 ft/s at any time. Sweep velocities increased toward the fish ladder. The air-burst mechanism appears to keep large debris off the screens, although it does not prevent algae and periphyton from growing on the screen face, especially near the bottom of the screens. In August 2006, the Gardena Farm Irrigation District personnel requested that we look for a leak beneath the inflatable rubber dam at the Garden City/Lowden II site that was preventing water movement through the fish ladder. Using our underwater video equipment, we were able to find a gap in the sheet piling beneath the dam. Erosion of the riverbed was occurring around this gap, allowing water and cobbles to move beneath the dam. The construction engineers and irrigation district staff were able to use the video footage to resolve the problem within a couple weeks. We had hoped to also evaluate the effectiveness of modifications to louvers behind the Nursery Bridge screens when flows were higher than 350 cubic feet per second, (cfs) but were unable to do so. Based on the one measurement made in early 2006 after the modified louvers were set, it appears the modified louvers may help reduce approach velocities. The auxiliary supply water system gates also control water through the screens. Evaluating the effect of different combinations of gate and louver positions on approach velocities through the screens may help identify optimum settings for both at different river discharges.« less

  19. A minimally invasive method for extraction of sturgeon oocytes

    USGS Publications Warehouse

    Candrl, James S.; Papoulias, Diana M.; Tillitt, Donald E.

    2010-01-01

    Fishery biologists, hatchery personnel, and caviar fishers routinely extract oocytes from sturgeon (Acipenseridae) to determine the stage of maturation by checking egg quality. Typically, oocytes are removed either by inserting a catheter into the oviduct or by making an incision in the body cavity. Both methods can be time-consuming and stressful to the fish. We describe a device to collect mature oocytes from sturgeons quickly and effectively with minimal stress on the fish. The device is made by creating a needle from stainless steel tubing and connecting it to a syringe with polyvinyl chloride tubing. The device is filled with saline solution or water, the needle is inserted into the abdominal wall, and eggs are extracted from the fish. Using this device, an oocyte sample can be collected in less than 30 s. Such sampling leaves a minute wound that heals quickly and does not require suturing. The extractor device can easily be used in the field or hatchery, reduces fish handling time, and minimizes stress.

  20. Acetylcholinesterase immobilized capillary reactors coupled to protein coated magnetic beads: A new tool for plant extract ligand screening

    PubMed Central

    Vanzolini, Kenia Lourenço; Jiang, Zhengjin; Zhang, Xiaoqi; Vieira, Lucas Campos Curcino; Corrêa, Arlene Gonçalvez; Cardoso, Carmen Lucia; Cass, Quezia Bezerra; Moaddel, Ruin

    2013-01-01

    The use of immobilized capillary enzyme reactors (ICERs) and enzymes coated to magnetic beads ((NT or CT)-MB) for ligand screening has been adopted as a new technique of high throughput screening (HTS). In this work the selected target was the enzyme acetylcholinesterase (AChE), which acts on the central nervous system and is a validated target for the treatment of Alzheimer’s disease, as well as for new insecticides. A new approach for the screening of plant extracts was developed based on the ligand fishing experiments and zonal chromatography. For that, the magnetic beads were used for the ligand fishing experiments and capillary bioreactors for the activity assays. The latter was employed also under non-linear conditions to determine the affinity constants of known ligands, for the first time, as well as for the active fished ligand. PMID:24148457

  1. A SIMPLE AND RAPID MATRIX-ASSISTED LASER DESORPTION/IONIZATION TIME OF FLIGHT MASS SPECTROMETRY METHOD TO SCREEN FISH PLASMA SAMPLES FOR ESTROGEN-RESPONSIVE BIOMARKERS

    EPA Science Inventory

    In this study, we describe and evaluate the performance of a simple and rapid mass spectral method for screening fish plasma for estrogen-responsive biomarkers using matrix assisted laster desorption/ionization time of flight mass spectrometry (MALDI-TOF-MS) couopled with a short...

  2. Immunohistochemistry is a reliable screening tool for identification of ALK rearrangement in non-small-cell lung carcinoma and is antibody dependent.

    PubMed

    Conklin, Chris M J; Craddock, Kenneth J; Have, Cherry; Laskin, Janessa; Couture, Christian; Ionescu, Diana N

    2013-01-01

    Fluorescence in situ hybridization (FISH) is the standard procedure for the detection of anaplastic lymphoma receptor tyrosine kinase (ALK) rearrangement in non-small-cell lung carcinoma (NSCLC) but is expensive and time consuming. We tested three antibodies to ALK, using various detection systems, and hypothesized that ALK immunohistochemistry (IHC) may represent a cost-effective and efficient means of screening for ALK rearrangement in NSCLC. We screened 377 stage I or II NSCLC cases in a tissue microarray by FISH and IHC (5A4 [Leica Biosystems Newcastle Ltd, Newcastle upon Tyne, UYnited Kingdom] by Nichirei's N-Histofine ALK detection kit [Nichirei Biosciences inc., Tokyo, Japan], 5A4 by Novocastra with ADVANCE [Dako Canada inc., Burlington, Ontario, Canada], D5F3 by Cell Signaling Technology with ADVANCE [Cell Signalling Technologies inc., Danvers, MA], and DAKO clone ALK1 with FLEX [Dako Canada inc., Burlington, Ontario, Canada] and ADVANCE). IHC was scored as 0, 1+, 2+, or 3+. Possibly positive or positive cases were further analyzed by IHC and FISH on whole section. Tissue microarray results were available on 377 cases by IHC and 273 cases by FISH. Eleven cases were positive or possibly positive by either IHC or FISH, and three cases were positive or possibly positive by both methods. Three cases were ALK-positive by FISH on whole section validation. There was no correlation between semiquantitative IHC score (1+, 2+, 3+) and ALK rearrangement by FISH. D5F3 (Cell Signaling by ADVANCE) and 5A4 (Novocastra by ADVANCE) showed the greatest combination of sensitivity (100%) and specificity (87.5% for 5A4 by Novocastra and 75% for D5F3 by Cell Signaling), and produced no false-negative results. IHC is a reliable screening tool for identification of ALK rearrangement in NSCLC and is antibody dependent. D5F3 (Cell Signaling) and 5A4 (Novocastra) can be used with FISH for identification of IHC-positive cases to reduce screening costs.

  3. Subsampling program for the estimation of fish impingement

    NASA Astrophysics Data System (ADS)

    Beauchamp, John J.; Kumar, K. D.

    1984-11-01

    Federal regulations require operators of nuclear and coal-fired power-generating stations to estimate the number of fish impinged on intake screens. During winter months, impingement may range into the hundreds of thousands for certain species, making it impossible to count all intake screens completely. We present graphs for determinig the appropriate“optimal” subsample that must be obtained to estimate the total number impinged. Since the number of fish impinged tends to change drastically within a short time period, the subsample size is determined based on the most recent data. This allows for the changing nature of the species-age composition of the impinged fish. These graphs can also be used for subsampling fish catches in an aquatic system when the size of the catch is too large to sample completely.

  4. 13. Detail view of drum screen short shaft gears, journal ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. Detail view of drum screen short shaft gears, journal bearing, rotation drive chain, upper sprocket gear, and drum screen edge in background, facing southeast (downstream) from drum screen cover. - Congdon Canal, Fish Screen, Naches River, Yakima, Yakima County, WA

  5. N-Screen Aware Multicriteria Hybrid Recommender System Using Weight Based Subspace Clustering

    PubMed Central

    Ullah, Farman; Lee, Sungchang

    2014-01-01

    This paper presents a recommender system for N-screen services in which users have multiple devices with different capabilities. In N-screen services, a user can use various devices in different locations and time and can change a device while the service is running. N-screen aware recommendation seeks to improve the user experience with recommended content by considering the user N-screen device attributes such as screen resolution, media codec, remaining battery time, and access network and the user temporal usage pattern information that are not considered in existing recommender systems. For N-screen aware recommendation support, this work introduces a user device profile collaboration agent, manager, and N-screen control server to acquire and manage the user N-screen devices profile. Furthermore, a multicriteria hybrid framework is suggested that incorporates the N-screen devices information with user preferences and demographics. In addition, we propose an individual feature and subspace weight based clustering (IFSWC) to assign different weights to each subspace and each feature within a subspace in the hybrid framework. The proposed system improves the accuracy, precision, scalability, sparsity, and cold start issues. The simulation results demonstrate the effectiveness and prove the aforementioned statements. PMID:25152921

  6. Evaluating the Potential for Marine and Hydrokinetic Devices to Act As Artificial Reefs or Fish Aggregating Devices

    NASA Astrophysics Data System (ADS)

    Kramer, S.; Nelson, P.

    2016-02-01

    Wave energy converters (WECs) and tidal energy converters (TECs) are only beginning to be deployed along the U.S. West Coast and in Hawai'i, and a better understanding of their ecological effects on fish, particularly on special status fish is needed to facilitate project siting, design and environmental permitting. The structures of WECs and TECs placed on to the seabed, such as anchors and foundations, may function as artificial reefs that attract reef associated fishes, while the midwater and surface structures, such as mooring lines, buoys, and wave or tidal power devices, may function as fish aggregating devices (FADs). We evaluated these potential ecological interactions by comparing them to surrogate structures, such as artificial reefs, natural reefs, kelp vegetation, floating and sunken debris, oil and gas platforms, anchored FADs deployed to enhance fishing opportunities, net cages used for mariculture, and piers and marinas. We also conducted guided discussions with scientists and resource managers to provide unpublished observations. Our findings indicate the structures of WECs and TECs placed on or near the seabed in coastal waters of the U.S. West Coast and Hawai`i likely will function as small scale artificial reefs and attract potentially high densities of reef associated fishes and the midwater and surface structures of WECs placed in the tropical waters of Hawai`i likely will function as de facto FADs.

  7. 78 FR 16705 - Llano Seco Riparian Sanctuary Unit Restoration and Pumping Plant/Fish Screen Facility Protection...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-18

    ... Riparian Sanctuary Unit by the Department of Water Resources in 1985 and 1986. The rock was placed in order... activities would not impact the Goose Lake overflow structure that diverts flood water into the Butte Basin..., the angle of flow and velocity of the water passing the screens will change, trapping fish against the...

  8. Occult hemoglobin as an indicator of impingement stress in fishes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1980-01-01

    During the process of impingement on cooling system intake screens, fish may be subject to different types of stress, the total of which often results in the death of individual fish. This report assesses the use of occult hemoglobin in fish demand mucus as an indicator of impingement stress. (ACR)

  9. Miniature sonar fish tag

    NASA Technical Reports Server (NTRS)

    Lovelady, R. W.; Ferguson, R. L.

    1975-01-01

    Self-powered sonar device may be implanted in body of fish. It transmits signal that can be detected with portable tracking gear or by automatic detection-and-tracking system. Operating life of over 4000 hours may be expected. Device itself may be used almost indefinitely.

  10. Behavioral Responses Of Fish To A Current-Based Hydrokinetic Turbine Under Mutlipe Operational Conditions: Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grippo, Mark A.; Shen, Haixue; Zydlewski, Gayle

    There is significant interest in the interaction of aquatic organisms with current-based marine and hydrokinetic (MHK) technologies. Determining the potential impacts of MHK devices on fish behavior is critical to addressing the environmental concerns that could act as barriers to the permitting and deployment of MHK devices. To address these concerns, we use field monitoring and fish behavior models to characterize the behavioral responses of fish to MHK turbines and infer potential stimuli that may have elicited the observed behavioral changes.

  11. 21 CFR 886.1810 - Tangent screen (campimeter).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) Identification. A tangent screen (campimeter) is an AC-powered or battery-powered device that is a large square... a patient's visual field. This generic type of device includes projection tangent screens, target... (general controls). The AC-powered device and the battery-powered device are exempt from the premarket...

  12. 21 CFR 886.1810 - Tangent screen (campimeter).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) Identification. A tangent screen (campimeter) is an AC-powered or battery-powered device that is a large square... a patient's visual field. This generic type of device includes projection tangent screens, target... (general controls). The AC-powered device and the battery-powered device are exempt from the premarket...

  13. 21 CFR 886.1810 - Tangent screen (campimeter).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) Identification. A tangent screen (campimeter) is an AC-powered or battery-powered device that is a large square... a patient's visual field. This generic type of device includes projection tangent screens, target... (general controls). The AC-powered device and the battery-powered device are exempt from the premarket...

  14. 21 CFR 886.1810 - Tangent screen (campimeter).

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) Identification. A tangent screen (campimeter) is an AC-powered or battery-powered device that is a large square... a patient's visual field. This generic type of device includes projection tangent screens, target... (general controls). The AC-powered device and the battery-powered device are exempt from the premarket...

  15. Ligand Fishing: A Remarkable Strategy for Discovering Bioactive Compounds from Complex Mixture of Natural Products.

    PubMed

    Zhuo, Rongjie; Liu, Hao; Liu, Ningning; Wang, Yi

    2016-11-11

    Identification of active compounds from natural products is a critical and challenging task in drug discovery pipelines. Besides commonly used bio-guided screening approaches, affinity selection strategy coupled with liquid chromatography or mass spectrometry, known as ligand fishing, has been gaining increasing interest from researchers. In this review, we summarized this emerging strategy and categorized those methods as off-line or on-line mode according to their features. The separation principles of ligand fishing were introduced based on distinct analytical techniques, including biochromatography, capillary electrophoresis, ultrafiltration, equilibrium dialysis, microdialysis, and magnetic beads. The applications of ligand fishing approaches in the discovery of lead compounds were reviewed. Most of ligand fishing methods display specificity, high efficiency, and require less sample pretreatment, which makes them especially suitable for screening active compounds from complex mixtures of natural products. We also summarized the applications of ligand fishing in the modernization of Traditional Chinese Medicine (TCM), and propose some perspectives of this remarkable technique.

  16. Evaluation of Fish Passage Sites in the Walla Walla River Basin, 2008

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chamness, Mickie A.

    2008-08-29

    In 2008, Pacific Northwest National Laboratory evaluated the Hofer Dam fish screen and provided technical assistance at two other fish passage sites as requested by the Bonneville Power Administration, the Walla Walla Watershed Council, or the Confederated Tribes of the Umatilla Indian Reservation. Evaluation of new sites such as Hofer Dam focuses on their design, construction, operation, and maintenance to determine if they effectively provide juvenile salmonids with safe passage through irrigation diversions. There were two requests for technical assistance in 2008. In the first, the Confederated Tribes of the Umatilla Indian Reservation requested an evaluation of the Nursery Bridgemore » fish screens associated with the fish ladder on the east side of the Walla Walla River. One set of brushes that clean the screens was broken for an extended period. Underwater videography and water velocity measurements were used to determine there were no potential adverse effects on juvenile salmonids when the west set of screens was clean enough to pass water normally. A second request, received from the National Marine Fisheries Service and the Walla Walla Watershed Council, asked for evaluation of water velocities through relatively new head gates above and adjacent to the Eastside Ditch fish screens on the Walla Walla River. Water moving through the head gates and not taken for irrigation is diverted to provide water for the Nursery Bridge fish ladder on the east side of the river. Elevations used in the design of the head gates were incorrect, causing excessive flow through the head gates that closely approached or exceeded the maximum swimming burst speed of juvenile salmonids. Hofer Dam was evaluated in June 2008. PNNL researchers found that conditions at Hofer Dam will not cause impingement or entrainment of juvenile salmonids but may provide habitat for predators and lack strong sweeping flows to encourage juvenile salmonid passage downstream. Further evaluation of velocities at the Eastside Ditch and wasteway gates should occur as changes are made to compensate for the design problems. These evaluations will help determine whether further changes are required. Hofer Dam also should be evaluated again under more normal operating conditions when the river levels are typical of those when fish are emigrating and the metal plate is not affecting flows.« less

  17. Lentic, lotic, and sulfate-dependent waterborne selenium screening guidelines for freshwater systems.

    PubMed

    DeForest, David K; Brix, Kevin V; Elphick, James R; Rickwood, Carrie J; deBruyn, Adrian M H; Tear, Lucinda M; Gilron, Guy; Hughes, Sarah A; Adams, William J

    2017-09-01

    There is consensus that fish are the most sensitive aquatic organisms to selenium (Se) and that Se concentrations in fish tissue are the most reliable indicators of potential toxicity. Differences in Se speciation, biological productivity, Se concentration, and parameters that affect Se bioavailability (e.g., sulfate) may influence the relationship between Se concentrations in water and fish tissue. It is desirable to identify environmentally protective waterborne Se guidelines that, if not exceeded, reduce the need to directly measure Se concentrations in fish tissue. Three factors that should currently be considered in developing waterborne Se screening guidelines are 1) differences between lotic and lentic sites, 2) the influence of exposure concentration on Se partitioning among compartments, and 3) the influence of sulfate on selenate bioavailability. Colocated data sets of Se concentrations in 1) water and particulates, 2) particulates and invertebrates, and 3) invertebrates and fish tissue were compiled; and a quantile regression approach was used to derive waterborne Se screening guidelines. Use of a regression-based approach for describing relationships in Se concentrations between compartments reduces uncertainty associated with selection of partitioning factors that are generally not constant over ranges of exposure concentrations. Waterborne Se screening guidelines of 6.5 and 3.0 μg/L for lotic and lentic water bodies were derived, and a sulfate-based waterborne Se guideline equation for selenate-dominated lotic waters was also developed. Environ Toxicol Chem 2017;36:2503-2513. © 2017 SETAC. © 2017 SETAC.

  18. The control of the upstream movement of fish with pulsated direct current

    USGS Publications Warehouse

    McLain, Alberton L.

    1957-01-01

    In the Silver River, 78,648 fish comprising 21 species were taken from the trap of the direct-current diversion device. The total kill of fish moving upstream, including 289 sea lampreys, was 1,016, or 1.3 percent. This river had presented a serious problem in the operation of an alternating-current control device during previous seasons. In 1955, 85.5 percent of three important species of fish were killed at the control structure. During 1956, this mortality was reduced to 8.1 percent by the operation of the direct-current equipment.

  19. 50 CFR 648.146 - Special management zones.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... for an artificial reef, fish attraction device, or other modification of habitat for purposes of... that are not compatible with the intent of the artificial reef or fish attraction device or other... Magnuson-Stevens Act, and other applicable law. (5) The natural bottom in and surrounding potential SMZs...

  20. 77 FR 35745 - Highway Safety Programs; Conforming Products List of Screening Devices To Measure Alcohol in...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-14

    ..., battery powered device with a semiconductor sensor. (2) Alcohol Countermeasure Systems Corp., submitted...-0062] Highway Safety Programs; Conforming Products List of Screening Devices To Measure Alcohol in... Screening Devices to Measure Alcohol in Bodily Fluids dated, March 31, 2008 (73 FR 16956). DATES: Effective...

  1. Understanding the significance variables for fabrication of fish gelatin nanoparticles by Plackett-Burman design

    NASA Astrophysics Data System (ADS)

    Subara, Deni; Jaswir, Irwandi; Alkhatib, Maan Fahmi Rashid; Noorbatcha, Ibrahim Ali

    2018-01-01

    The aim of this experiment is to screen and to understand the process variables on the fabrication of fish gelatin nanoparticles by using quality-design approach. The most influencing process variables were screened by using Plackett-Burman design. Mean particles size, size distribution, and zeta potential were found in the range 240±9.76 nm, 0.3, and -9 mV, respectively. Statistical results explained that concentration of acetone, pH of solution during precipitation step and volume of cross linker had a most significant effect on particles size of fish gelatin nanoparticles. It was found that, time and chemical consuming is lower than previous research. This study revealed the potential of quality-by design in understanding the effects of process variables on the fish gelatin nanoparticles production.

  2. Acanthocephalan fish parasites (Rhadinorhynchidae Lühe, 1912) as potential biomarkers: Molecular-chemical screening by pyrolysis-field ionization mass spectrometry

    NASA Astrophysics Data System (ADS)

    Kleinertz, S.; Eckhardt, K.-U.; Theisen, S.; Palm, H. W.; Leinweber, P.

    2016-07-01

    The present study represents the first molecular-chemical screening by pyrolysis-field ionization mass spectrometry applied on fish parasites. A total of 71 fishes from Balinese fish markets, 36 Auxis rochei (Risso, 1810) and 35 A. thazard (Lacepède, 1800), were studied for their acanthocephalan parasites. This is the first record of Rhadinorhynchus zhukovi in Balinese waters, Indonesia, and we describe for the first time A. rochei and A. thazard as R. zhukovi hosts. Using this method, small scale variations within the chemical compounds of acanthocephalans could be detected. Using this methodology it will be possible to generate additional, pollutant specific information from aquatic habitats in future with the potential of a new bioindicator application for parasite/host origin and/or environmental pollution.

  3. The common neural parasite Pseudoloma neurophilia is associated with altered startle response habituation in adult zebrafish (Danio rerio): Implications for the zebrafish as a model organism

    PubMed Central

    Spagnoli, Sean; Xue, Lan; Kent, Michael L.

    2015-01-01

    The zebrafish’s potential as a model for human neurobehavioral research appears nearly limitless despite its relatively recent emergence as an experimental organism. Since the zebrafish has only been part of the research community for a handful of decades, pathogens from its commercial origins continue to plague laboratory stocks. One such pathogen is Pseudoloma neurophilia, a common microparasite in zebrafish laboratories world-wide that generally produces subclinical infections. Given its high prevalence, its predilection for the host’s brain and spinal cord, and the delicate nature of neurobehavioral research, the behavioral consequences of subclinical P. neurophilia infection must be explored. Fish infected via cohabitation were tested for startle response habituation in parallel with controls in a device that administered ten taps over ten minutes along with taps at 18 and 60 minutes to evaluate habituation extinction. After testing, fish were euthanized and evaluated for infection via histopathology. Infected fish had a significantly smaller reduction in startle velocity during habituation compared to uninfected tankmates and controls. Habituation was eliminated in infected and control fish at 18 minutes, whereas exposed negative fish retained partial habituation at 18 minutes. Infection was also associated with enhanced capture evasion: Despite the absence of external symptoms, infected fish tended to be caught later than uninfected fish netted from the same tank. The combination of decreased overall habituation, early extinction of habituation compared to uninfected cohorts, and enhanced netting evasion indicates that P. neurophilia infection is associated with a behavioral phenotype distinct from that of controls and uninfected cohorts. Because of its prevalence in zebrafish facilities, P. neurophilia has the potential to insidiously influence a wide range of neurobehavioral studies if these associations are causative. Rigorous health screening is therefore vital to the improvement of the zebrafish as a translational model for human behavior. PMID:26028515

  4. The common neural parasite Pseudoloma neurophilia is associated with altered startle response habituation in adult zebrafish (Danio rerio): Implications for the zebrafish as a model organism.

    PubMed

    Spagnoli, Sean; Xue, Lan; Kent, Michael L

    2015-09-15

    The zebrafish's potential as a model for human neurobehavioral research appears nearly limitless despite its relatively recent emergence as an experimental organism. Since the zebrafish has only been part of the research community for a handful of decades, pathogens from its commercial origins continue to plague laboratory stocks. One such pathogen is Pseudoloma neurophilia, a common microparasite in zebrafish laboratories world-wide that generally produces subclinical infections. Given its high prevalence, its predilection for the host's brain and spinal cord, and the delicate nature of neurobehavioral research, the behavioral consequences of subclinical P. neurophilia infection must be explored. Fish infected via cohabitation were tested for startle response habituation in parallel with controls in a device that administered ten taps over 10 min along with taps at 18 and 60 min to evaluate habituation extinction. After testing, fish were euthanized and evaluated for infection via histopathology. Infected fish had a significantly smaller reduction in startle velocity during habituation compared to uninfected tankmates and controls. Habituation was eliminated in infected and control fish at 18 min, whereas exposed negative fish retained partial habituation at 18 min. Infection was also associated with enhanced capture evasion: Despite the absence of external symptoms, infected fish tended to be caught later than uninfected fish netted from the same tank. The combination of decreased overall habituation, early extinction of habituation compared to uninfected cohorts, and enhanced netting evasion indicates that P. neurophilia infection is associated with a behavioral phenotype distinct from that of controls and uninfected cohorts. Because of its prevalence in zebrafish facilities, P. neurophilia has the potential to insidiously influence a wide range of neurobehavioral studies if these associations are causative. Rigorous health screening is therefore vital to the improvement of the zebrafish as a translational model for human behavior. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Impacts of electromagnetic fields associated with marine and hydrokinetic surrogate technologies on fish movements and behaviors.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Claisse, Jeremy T.; Pondella, Daniel J.; Williams, Chelsea M.

    Marine and hydrokinetic energy (MHK) and offshore wind devices are being developed and deployed in U.S. and international waters. Electric current flowing through subsea transmission cables associated with these devices will generate electromagnetic fields (EMF), which may interact with, and potentially impact, marine fishes. Some marine fishes can detect electric and/or magnetic fields and use them to navigate, orientate, and sense prey, mates and predators. Over the past five years there have been multiple comprehensive reviews and studies evaluating the potential vulnerability of marine fishes to EMF produced by MHK devices. Most documented effects involve sub-lethal behavioral responses of individualmore » fish when in close proximity to EMF (e.g., fish being repelled by or attracted to fields). These reviews reach conclusions that the current state of research on this topic is still in its infancy and evaluations of potential impacts are associated with great uncertainty. A variety of MHK technologies are likely to be considered for deployment offshore of the Hawaiian Islands, and there is a need to be able to better predict and assess potential associated environmental impacts. The goal of this study was to provide a complementary piece to these previous reviews (e.g., Normandeau et al. 2011) by focusing on marine fish species in the Hawaii region. We compiled the relevant available information, then prioritized fish species as candidates for various paths of future research. To address this, we first developed a list of Hawaii Region Focal Species, which included fishes that are more likely to be sensitive to EMF. We then compiled species-specific information available in the literature on their sensitivity to EMF, as well as life history, movement and habitat use information that could inform an analysis of their likelihood of encountering EMF from subsea cables associated with MHK devices. Studies have only documented EMF sensitivity in 11 of the marine fish species in this region. There was also relatively little detailed information on fish movement and habitat use patterns for most of the focal species. Our last objective was to develop recommendations for research needs to close the important knowledge gaps. We describe species-independent baseline research that primarily consists of in situ quantification of EMF generated by MHK devices and undersea cables that can occur as pilot and commercial scale MHK devices are deployed in Hawaii. Then we propose a simple approach for prioritizing Hawaii Region Focal Species (ranked relative to each other) as candidates in multiple related research paths. The prioritization approach incorporates EMF sensitivity information with the likelihood of interacting with EMF generated undersea transmission cables associated with MHK devices. Finally, we discuss the types of research needed to help fill gaps in the scientific knowledge base for this region. These involve studies to better define species-specific EMF sensitivity thresholds under various environmental conditions, studies of life history, movement and habitat use patterns to improve our understanding of the likelihood and frequency fishes may be in the vicinity of EMF generated by subsea transmission cables, and studies of the potential for related population, community or ecosystem impacts. Many of these studies can and should occur opportunistically as pilot and commercial scale MHK devices are deployed in Hawaii.« less

  6. CONNECTICUT RIVER FISH TISSUE CONTAMINANT STUDY (2000): ECOLOGICAL AND HUMAN HEALTH RISK SCREENING

    EPA Science Inventory

    The study targeted commonly caught recreational fish, as well as other fish that are important in the river food chain. Smallmouth bass, white suckers and yellow perch were collected during 2000 from the mainstem of the Connecticut River and composite samples were analyzed for t...

  7. High throughput screening of human subtelomeric DNA for copy number changes using multiplex amplifiable probe hybridisation (MAPH).

    PubMed

    Hollox, E J; Atia, T; Cross, G; Parkin, T; Armour, J A L

    2002-11-01

    Subtelomeric regions of the human genome are gene rich, with a high level of sequence polymorphism. A number of clinical conditions, including learning disability, have been attributed to subtelomeric deletions or duplications, but screening for deletion in these regions using conventional cytogenetic methods and fluorescence in situ hybridisation (FISH) is laborious. Here we report that a new method, multiplex amplifiable probe hybridisation (MAPH), can be used to screen for copy number at subtelomeric regions. We have constructed a set of MAPH probes with each subtelomeric region represented at least once, so that one gel lane can assay copy number at all chromosome ends in one person. Each probe has been sequenced and, where possible, its position relative to the telomere determined by comparison with mapped clones. The sensitivity of the probes has been characterised on a series of cytogenetically verified positive controls and 83 normal controls were used to assess the frequency of polymorphic copy number with no apparent phenotypic effect. We have also used MAPH to test a cohort of 37 people selected from males referred for fragile X syndrome testing and found six changes that were confirmed by dosage PCR. MAPH can be used to screen subtelomeric regions of chromosomes for deletions and duplications before confirmation by FISH or dosage PCR. The high throughput nature of this technique allows it to be used for large scale screening of subtelomeric copy number, before confirmation by FISH. In practice, the availability of a rapid and efficient screen may allow subtelomeric analysis to be applied to a wider selection of patients than is currently possible using FISH alone.

  8. High throughput screening of human subtelomeric DNA for copy number changes using multiplex amplifiable probe hybridisation (MAPH)

    PubMed Central

    Hollox, E; Atia, T; Cross, G; Parkin, T; Armour, J

    2002-01-01

    Background: Subtelomeric regions of the human genome are gene rich, with a high level of sequence polymorphism. A number of clinical conditions, including learning disability, have been attributed to subtelomeric deletions or duplications, but screening for deletion in these regions using conventional cytogenetic methods and fluorescence in situ hybridisation (FISH) is laborious. Here we report that a new method, multiplex amplifiable probe hybridisation (MAPH), can be used to screen for copy number at subtelomeric regions. Methods: We have constructed a set of MAPH probes with each subtelomeric region represented at least once, so that one gel lane can assay copy number at all chromosome ends in one person. Each probe has been sequenced and, where possible, its position relative to the telomere determined by comparison with mapped clones. Results: The sensitivity of the probes has been characterised on a series of cytogenetically verified positive controls and 83 normal controls were used to assess the frequency of polymorphic copy number with no apparent phenotypic effect. We have also used MAPH to test a cohort of 37 people selected from males referred for fragile X syndrome testing and found six changes that were confirmed by dosage PCR. Conclusions: MAPH can be used to screen subtelomeric regions of chromosomes for deletions and duplications before confirmation by FISH or dosage PCR. The high throughput nature of this technique allows it to be used for large scale screening of subtelomeric copy number, before confirmation by FISH. In practice, the availability of a rapid and efficient screen may allow subtelomeric analysis to be applied to a wider selection of patients than is currently possible using FISH alone. PMID:12414816

  9. 50 CFR 622.30 - Required fishing gear.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 50 Wildlife and Fisheries 12 2014-10-01 2014-10-01 false Required fishing gear. 622.30 Section 622... Resources of the Gulf of Mexico § 622.30 Required fishing gear. For a person on board a vessel to fish for... steel circle hooks are required when fishing with natural baits. (b) Dehooking device. At least one...

  10. Ecological risk of methylmercury to piscivorous fish of the Great Lakes region.

    PubMed

    Sandheinrich, Mark B; Bhavsar, Satyendra P; Bodaly, R A; Drevnick, Paul E; Paul, Eric A

    2011-10-01

    Contamination of fish populations with methylmercury is common in the region of the Laurentian Great Lakes as a result of atmospheric deposition and methylation of inorganic mercury. Using fish mercury monitoring data from natural resource agencies and information on tissue concentrations injurious to fish, we conducted a screening-level risk assessment of mercury to sexually mature female walleye (Sander vitreus), northern pike (Esox lucius), smallmouth bass (Micropterus dolomieu), and largemouth bass (Micropterus salmoides) in the Great Lakes and in interior lakes, impoundments, and rivers of the Great Lakes region. The assessment included more than 43,000 measurements of mercury in fish from more than 2000 locations. Sexually mature female fish that exceeded threshold-effect tissue concentrations of 0.20 μg g(-1) wet weight in the whole body occurred at 8% (largemouth bass) to 43% (walleye) of sites. Fish at 3% to 18% of sites were at risk of injury and exceeded 0.30 μg g(-1) where an alteration in reproduction or survival is predicted to occur. Most fish at increased risk were from interior lakes and impoundments. In the Great Lakes, no sites had sexually mature fish that exceeded threshold-effect concentrations. Results of this screening-level assessment indicate that fish at a substantive number of locations within the Great Lakes region are potentially at risk from methylmercury contamination and would benefit from reduction in mercury concentrations.

  11. A Network and Visual Quality Aware N-Screen Content Recommender System Using Joint Matrix Factorization

    PubMed Central

    Ullah, Farman; Sarwar, Ghulam; Lee, Sungchang

    2014-01-01

    We propose a network and visual quality aware N-Screen content recommender system. N-Screen provides more ways than ever before to access multimedia content through multiple devices and heterogeneous access networks. The heterogeneity of devices and access networks present new questions of QoS (quality of service) in the realm of user experience with content. We propose, a recommender system that ensures a better visual quality on user's N-screen devices and the efficient utilization of available access network bandwidth with user preferences. The proposed system estimates the available bandwidth and visual quality on users N-Screen devices and integrates it with users preferences and contents genre information to personalize his N-Screen content. The objective is to recommend content that the user's N-Screen device and access network are capable of displaying and streaming with the user preferences that have not been supported in existing systems. Furthermore, we suggest a joint matrix factorization approach to jointly factorize the users rating matrix with the users N-Screen device similarity and program genres similarity. Finally, the experimental results show that we also enhance the prediction and recommendation accuracy, sparsity, and cold start issues. PMID:24982999

  12. 21 CFR 892.1960 - Radiographic intensifying screen.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiographic intensifying screen. 892.1960 Section 892.1960 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1960 Radiographic intensifying screen...

  13. USE OF WHOLE BODY CHEMICAL RESIDUE ANALYSIS AND LASER SCREENING CONFOCAL MICROSCOPY TO DESCRIBE DISTRIBUTION OF PBTS IN FISH EARLY LIFE STAGES

    EPA Science Inventory

    Fish early life stages (ELS) are more sensitive than juveniles or adults to many persistent bioaccumulative toxicants (PBTs). To better understand the mechanisms by which these chemicals produce toxicity during fish ELS, dose-response relationships need to be determined in relat...

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abernethy, C. Scott; Neitzel, Duane A.; Lusty, E. William

    The Bonneville Power Administration (BPA), the United States Bureau of Reclamation (USSR), and the Washington State Department of Ecology (WDOE) are funding the construction and evaluation of fish passage facilities and fish protection facilities at irrigation and hydroelectric diversions in the Yakima River Basin, Washington State. The program provides offsite enhancement to compensate for fish and wildlife losses caused by hydroelectric development throughout the Columbia River Basin, and addresses natural propagation of salmon to help mitigate the impact of irrigation in the Yakima River Basin. This report evaluates the flow characteristics of the screening facilities. Studies consisted of velocity measurementsmore » taken in front of the rotary drum screens and within the fish bypass systems during peak flows. Measurements of approach velocity and sweep velocity were emphasized in these studies; however, vertical velocity was also measured. 5 refs., 18 figs., 15 tabs.« less

  15. Fishing anti(lymph)angiogenic drugs with zebrafish.

    PubMed

    García-Caballero, Melissa; Quesada, Ana R; Medina, Miguel A; Marí-Beffa, Manuel

    2018-02-01

    Zebrafish, an amenable small teleost fish with a complex mammal-like circulatory system, is being increasingly used for drug screening and toxicity studies. It combines the biological complexity of in vivo models with a higher-throughput screening capability compared with other available animal models. Externally growing, transparent embryos, displaying well-defined blood and lymphatic vessels, allow the inexpensive, rapid, and automatable evaluation of drug candidates that are able to inhibit neovascularisation. Here, we briefly review zebrafish as a model for the screening of anti(lymph)angiogenic drugs, with emphasis on the advantages and limitations of the different zebrafish-based in vivo assays. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Disparity between state fish consumption advisory systems for Methylmercury and US Environmental Protection Agency recommendations: a case study of the South Central United States

    USGS Publications Warehouse

    Adams, Kimberly; Drenner, Ray W.; Chumchal, Matthew M.; Donato, David I.

    2015-01-01

    Fish consumption advisories are used to inform citizens in the United States about noncommercial game fish with hazardous levels of methylmercury (MeHg). The US Environmental Protection Agency (USEPA) suggests issuing a fish consumption advisory when concentrations of MeHg in fish exceed a human health screening value of 300 ng/g. However, states have authority to develop their own systems for issuing fish consumption advisories for MeHg. Five states in the south central United States (Arkansas, Louisiana, Mississippi, Oklahoma, and Texas) issue advisories for the general human population when concentrations of MeHg exceed 700 ng/g to 1000 ng/g. The objective of the present study was to estimate the increase in fish consumption advisories that would occur if these states followed USEPA recommendations. The authors used the National Descriptive Model of Mercury in Fish to estimate the mercury concentrations in 5 size categories of largemouth bass–equivalent fish at 766 lentic and lotic sites within the 5 states. The authors found that states in this region have not issued site-specific fish consumption advisories for most of the water bodies that would have such advisories if USEPA recommendations were followed. One outcome of the present study may be to stimulate discussion between scientists and policy makers at the federal and state levels about appropriate screening values to protect the public from the health hazards of consuming MeHg-contaminated game fish.

  17. Molecular confirmation of infectious spleen and kidney necrosis virus (ISKNV) in farmed and imported ornamental fish in Australia.

    PubMed

    Mohr, Peter G; Moody, Nicholas J G; Williams, Lynette M; Hoad, John; Cummins, David M; Davies, Kelly R; StJ Crane, Mark

    2015-10-16

    Viruses of the genus Megalocytivirus have not been detected in wild populations of fish in Australia but circulate in imported ornamental fish. In 2012, detection of a megalocytivirus in healthy platys Xiphophorus maculatus was reported from a farm in Australia during surveillance testing as part of a research project undertaken at the University of Sydney. Confirmatory testing of the original samples at the AAHL Fish Diseases Laboratory verified the presence of an infectious spleen and kidney necrosis virus (ISKNV)-like virus. Additional sampling at the positive farm confirmed the persistence of the virus in the platys, with 39 of 265 (14.7%) samples testing positive. Comparison of 3 separate gene regions of the virus with those of ISKNV confirmed the detection of a virus indistinguishable from ISKNV. Subsequently, ISKNV was also detected in a range of imported ornamental fish from several countries between 2013 and 2014, by screening with real-time PCR and confirmation by conventional PCR and sequence analysis. Accordingly, the current importation of live ornamental fish acts as a potential perpetual source for the establishment of ISKNV viruses within Australia. The testing of the farmed and imported ornamental fish verified the utility of the probe-based real-time PCR assay for screening of ornamental fish for Megalocytivirus.

  18. Aquatic Communities and Selected Water Chemistry in St. Vrain Creek near the City of Longmont, Colorado, Wastewater-Treatment Plant, 2005 and 2006

    USGS Publications Warehouse

    Zuellig, Robert E.; Sprague, Lori A.; Collins, Jim A.; Cox, Oliver N.

    2007-01-01

    In 2005, the U.S. Geological Survey and the City of Longmont, Colo., began a study to document chemical characteristics of St. Vrain Creek that had previously been unavailable either due to high cost of analysis or lack of analytical capability. Stream samples were collected at seven sites on St. Vrain Creek during the spring of 2005 and 2006 for analysis of wastewater compounds. A Lagrangian-sampling design was followed during each sampling event, and time-of-travel studies were conducted just prior to each sampling event to determine appropriate sampling times for the synoptic. In addition, semipermeable membrane devices, passive samplers that concentrate hydrophobic organic chemicals, were installed at six sites during the spring of 2005 and 2006 for approximately 4 weeks. After retrieval, contaminant residues concentrated in the semipermeable membrane devices were recovered and used in a toxicity assay that provided a screen for aryl hydrocarbon receptor type compounds, including polycyclic aromatic hydrocarbons, polychlorinated biphenyls, dioxins, and furans. In addition, the U.S. Geological Survey summarized information on macroinvertebrate and fish communities known from St. Vrain Creek dating back to the early 1900s in order to assess their utility in evaluating wastewater-treatment plant upgrades and habitat improvement projects. Unfortunately, because of inconsistencies in data collection these data cannot be used as intended; however, they are useful for understanding to some degree gross patterns in fish species distribution, but less so for macroinvertebrates.

  19. Applications of the Sensor Fish Technology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deng, Zhiqun; Carlson, Thomas J.; Duncan, Joanne P.

    2007-08-28

    The Sensor Fish is an autonomous device developed at Pacific Northwest National Laboratory for U.S. Department of Energy (DOE) and Army Corps of Engineers (COE) to better understand the physical conditions fish experience during passage through hydro-turbines and other dam bypass alternatives. Since its initial development in 1997, the Sensor Fish has undergone several design changes to improve its function and extend the range of its use. The most recent Sensor Fish design, the six-degree-of-freedom (6DOF) device, has been deployed successfully to characterize the environment fish experience when they pass through several hydroelectric projects along main stem Columbia and Snakemore » Rivers in the Pacific Northwest. Just as information gathered from crash test dummies can affect automobile design with the installation of protective designs to lessen or prevent human injury, having sensor fish data to quantify accelerations, rotations, and pressure changes, helps identify fish injury mechanisms such as strike, turbulent shear, pressure, and inertial effects, including non-lethal ones such as stunning or signs of vestibular disruption that expose fish to a higher risk of predation by birds and piscivorous fish downstream following passage.« less

  20. Predicting invasiveness of species in trade: Climate match, trophic guild and fecundity influence establishment and impact of non-native freshwater fishes

    USGS Publications Warehouse

    Howeth, Jennifer G.; Gantz, Crysta A.; Angermeier, Paul; Frimpong, Emmanuel A.; Hoff, Michael H.; Keller, Reuben P.; Mandrak, Nicholas E.; Marchetti, Michael P.; Olden, Julian D.; Romagosa, Christina M.; Lodge, David M.

    2016-01-01

    AimImpacts of non-native species have motivated development of risk assessment tools for identifying introduced species likely to become invasive. Here, we develop trait-based models for the establishment and impact stages of freshwater fish invasion, and use them to screen non-native species common in international trade. We also determine which species in the aquarium, biological supply, live bait, live food and water garden trades are likely to become invasive. Results are compared to historical patterns of non-native fish establishment to assess the relative importance over time of pathways in causing invasions.LocationLaurentian Great Lakes region.MethodsTrait-based classification trees for the establishment and impact stages of invasion were developed from data on freshwater fish species that established or failed to establish in the Great Lakes. Fishes in trade were determined from import data from Canadian and United States regulatory agencies, assigned to specific trades and screened through the developed models.ResultsClimate match between a species’ native range and the Great Lakes region predicted establishment success with 75–81% accuracy. Trophic guild and fecundity predicted potential harmful impacts of established non-native fishes with 75–83% accuracy. Screening outcomes suggest the water garden trade poses the greatest risk of introducing new invasive species, followed by the live food and aquarium trades. Analysis of historical patterns of introduction pathways demonstrates the increasing importance of these trades relative to other pathways. Comparisons among trades reveal that model predictions parallel historical patterns; all fishes previously introduced from the water garden trade have established. The live bait, biological supply, aquarium and live food trades have also contributed established non-native fishes.Main conclusionsOur models predict invasion risk of potential fish invaders to the Great Lakes region and could help managers prioritize efforts among species and pathways to minimize such risk. Similar approaches could be applied to other taxonomic groups and geographic regions.

  1. Technologies for the marking of fishing gear to identify gear components entangled on marine animals and to reduce abandoned, lost or otherwise discarded fishing gear.

    PubMed

    He, Pingguo; Suuronen, Petri

    2018-04-01

    Fishing gears are marked to establish and inform origin, ownership and position. More recently, fishing gears are marked to aid in capacity control, reduce marine litter due to abandoned, lost or otherwise discarded fishing gear (ALDFG) and assist in its recovery, and to combat illegal, unreported and unregulated (IUU) fishing. Traditionally, physical marking, inscription, writing, color, shape, and tags have been used for ownership and capacity purposes. Buoys, lights, flags, and radar reflectors are used for marking of position. More recently, electronic devices have been installed on marker buoys to enable easier relocation of the gear by owner vessels. This paper reviews gear marking technologies with focus on coded wire tags, radio frequency identification tags, Automatic Identification Systems, advanced electronic buoys for pelagic longlines and fish aggregating devices, and re-location technology if the gear becomes lost. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Two-Way Radio Modem Data Transfer for Newborn Hearing Screening Devices.

    PubMed

    Matulat, Peter; Lepper, Ingo; Böttcher, Peter; Parfitt, Ross; Oswald, Hans; Am Zehnhoff-Dinnesen, Antoinette; Deuster, Dirk

    2017-01-01

    The success of a newborn hearing screening program depends on successful tracking and follow-up to ensure that children who have had positive screening results in the first few days of life receive appropriate and timely diagnostic and intervention services. The easy availability, through a suitable infrastructure, of the data necessary for the tracking, diagnosis, and care of children concerned is a major key to enhancing the quality and efficiency of newborn hearing screening programs. Two systems for the automated two-way transmission of newborn hearing screening and configuration data, based on mobile communication technology, for the screening devices MADSEN AccuScreen ® and Natus Echo-Screen ® were developed and tested in a field study. Radio modem connections were compared with conventional analogue modem transmissions from Natus Echo-Screen devices for duration, transmission rate, number of lost connections, and frequency of use. The average session duration was significantly lower with the MADSEN AccuScreen (12 s) and Natus Echo-Screen both with radio modem (15 s) than the Natus Echo-Screen with analogue modem (108 s). The transmission rate was significantly higher (898 and 1,758 vs. 181 bytes/s) for the devices with radio modems. Both radio modem devices had significantly lower rates of broken connections after initial connection (2.1 and 0.9 vs. 5.5%). An increase in the frequency of data transmission from the clinics with mobile radio devices was found. The use of mobile communication technology in newborn hearing screening devices offers improvements in the average session duration, transmission rate, and reliability of the connection over analogue solutions. We observed a behavioral change in clinical staff using the new technology: the data exchange with the tracking center is more often used. The requirements for on-site support were reduced. These savings outweigh the small increase in costs for the Internet service provider.

  3. Reducing the Impacts of Hydroelectric Dams on Juvenile Anadromous Fishes: Bioengineering Evaluations Using Acoustic Imaging in the Columbia River, USA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Gary E.; Ploskey, Gene R.; Hedgepeth, J.

    2008-07-29

    Dams impact the survival of juvenile anadromous fishes by obstructing migration corridors, lowering water quality, delaying migrations, and entraining fish in turbine discharge. To reduce these impacts, structural and operational modifications to dams— such as voluntary spill discharge, turbine intake guidance screens, and surface flow outlets—are instituted. Over the last six years, we have used acoustic imaging technology to evaluate the effects of these modifications on fish behavior, passage rates, entrainment zones, and fish/flow relationships at hydroelectric projects on the Columbia River. The imaging technique has evolved from studies documenting simple movement patterns to automated tracking of images to mergingmore » and analysis with concurrent hydraulic data. This chapter chronicles this evolution and shows how the information gleaned from the scientific evaluations has been applied to improve passage conditions for juvenile salmonids. We present data from Bonneville and The Dalles dams that document fish behavior and entrainment zones at sluiceway outlets (14 to 142 m3/s), fish passage rates through a gap at a turbine intake screen, and the relationship between fish swimming effort and hydraulic conditions. Dam operators and fisheries managers have applied these data to support decisions on operational and structural changes to the dams for the benefit of anadromous fish populations in the Columbia River basin.« less

  4. Screening for ROS1 gene rearrangements in non-small cell lung cancers using immunohistochemistry with FISH confirmation is an effective method to identify this rare target

    PubMed Central

    Selinger, Christina I; Li, Bob T; Pavlakis, Nick; Links, Matthew; Gill, Anthony J; Lee, Adrian; Clarke, Stephen; Tran, Thang N; Lum, Trina; Yip, Po Yee; Horvath, Lisa; Yu, Bing; Kohonen-Corish, Maija RJ; O’Toole, Sandra A; Cooper, Wendy A

    2016-01-01

    Aims To assess the prevalence of ROS1 rearrangements in a retrospective and prospective diagnostic Australian cohort and evaluate the effectiveness of immunohistochemical screening. Methods A retrospective cohort of 278 early stage lung adenocarcinomas and an additional 104 prospective NSCLC cases referred for routine molecular testing were evaluated. ROS1 immunohistochemistry (IHC) was performed (D4D6 clone, Cell Signaling Technology) on all cases as well as fluorescence in situ hybridisation (FISH) using the ZytoVision and Abbott Molecular ROS1 FISH probes, with ≥15% of cells with split signals considered positive for rearrangement. Results Eighty eight cases (32%) from the retrospective cohort showed staining by ROS1 IHC, and one case (0.4%) showed ROS1 rearrangement by FISH. Nineteen of the prospective diagnostic cases showed ROS1 IHC staining of which 12 (12%) cases were confirmed as ROS1 rearranged by FISH. There were no ROS1 rearranged cases that showed no expression of ROS1 with IHC. The ROS1 rearranged cases in the prospective cohort were all EGFR wildtype and ALK rearrangement negative. The sensitivity of ROS1 IHC in the retrospective cohort was 100% and specificity was 76%. Conclusions ROS1 rearrangements are rare events in lung adenocarcinomas. Selection of cases for ROS1 FISH testing, by excluding EGFR/ALK positive cases and use of IHC to screen for potentially positive cases can be used to enrich for the likelihood of a identifying a ROS1 rearranged lung cancer and prevent the need to undertake expensive and time consuming FISH testing in all cases. PMID:27599111

  5. Screening for ROS1 gene rearrangements in non-small-cell lung cancers using immunohistochemistry with FISH confirmation is an effective method to identify this rare target.

    PubMed

    Selinger, Christina I; Li, Bob T; Pavlakis, Nick; Links, Matthew; Gill, Anthony J; Lee, Adrian; Clarke, Stephen; Tran, Thang N; Lum, Trina; Yip, Po Y; Horvath, Lisa; Yu, Bing; Kohonen-Corish, Maija R J; O'Toole, Sandra A; Cooper, Wendy A

    2017-02-01

    To assess the prevalence of ROS1 rearrangements in a retrospective and prospective diagnostic Australian cohort and evaluate the effectiveness of immunohistochemical screening. A retrospective cohort of 278 early stage lung adenocarcinomas and an additional 104 prospective non-small-cell lung cancer (NSCLC) cases referred for routine molecular testing were evaluated. ROS1 immunohistochemistry (IHC) was performed (D4D6 clone, Cell Signaling Technology) on all cases as well as fluorescence in-situ hybridization (FISH) using the ZytoVision and Abbott Molecular ROS1 FISH probes, with ≥15% of cells with split signals considered positive for rearrangement. Eighty-eight cases (32%) from the retrospective cohort showed staining by ROS1 IHC, and one case (0.4%) showed ROS1 rearrangement by FISH. Nineteen of the prospective diagnostic cases showed ROS1 IHC staining, 12 (12%) cases of which were confirmed as ROS1 rearranged by FISH. There were no ROS1 rearranged cases that showed no expression of ROS1 with IHC. The ROS1 rearranged cases in the prospective cohort were all EGFR wild-type and anaplastic lymphoma kinase (ALK) rearrangement-negative. The sensitivity of ROS1 IHC in the retrospective cohort was 100% and specificity was 76%. ROS1 rearrangements are rare events in lung adenocarcinomas. Selection of cases for ROS1 FISH testing, by excluding EGFR/ALK-positive cases and use of IHC to screen for potentially positive cases, can be used to enrich for the likelihood of identifying a ROS1 rearranged lung cancer and prevent the need to undertake expensive and time-consuming FISH testing in all cases. © 2016 John Wiley & Sons Ltd.

  6. Statistical Survey of Persistent Organic Pollutants: Risk Estimations to Humans and Wildlife through Consumption of Fish from U.S. Rivers.

    PubMed

    Batt, Angela L; Wathen, John B; Lazorchak, James M; Olsen, Anthony R; Kincaid, Thomas M

    2017-03-07

    U.S. EPA conducted a national statistical survey of fish tissue contamination at 540 river sites (representing 82 954 river km) in 2008-2009, and analyzed samples for 50 persistent organic pollutants (POPs), including 21 PCB congeners, 8 PBDE congeners, and 21 organochlorine pesticides. The survey results were used to provide national estimates of contamination for these POPs. PCBs were the most abundant, being measured in 93.5% of samples. Summed concentrations of the 21 PCB congeners had a national weighted mean of 32.7 μg/kg and a maximum concentration of 857 μg/kg, and exceeded the human health cancer screening value of 12 μg/kg in 48% of the national sampled population of river km, and in 70% of the urban sampled population. PBDEs (92.0%), chlordane (88.5%) and DDT (98.7%) were also detected frequently, although at lower concentrations. Results were examined by subpopulations of rivers, including urban or nonurban and three defined ecoregions. PCBs, PBDEs, and DDT occur at significantly higher concentrations in fish from urban rivers versus nonurban; however, the distribution varied more among the ecoregions. Wildlife screening values previously published for bird and mammalian species were converted from whole fish to fillet screening values, and used to estimate risk for wildlife through fish consumption.

  7. Absence of subtelomeric rearrangements in selected patients with mental retardation as assessed by multiprobe T FISH

    PubMed Central

    2012-01-01

    Background Mental retardation (MR) is a heterogeneous condition that affects 2-3% of the general population and is a public health problem in developing countries. Chromosomal abnormalities are an important cause of MR and subtelomeric rearrangements (STR) have been reported in 4-35% of individuals with idiopathic MR or an unexplained developmental delay, depending on the screening tests and patient selection criteria used. Clinical checklists such as that suggested by de Vries et al. have been used to improve the predictive value of subtelomeric screening. Findings Fifteen patients (1–20 years old; five females and ten males) with moderate to severe MR from a genetics outpatient clinic of the Gaffrée and Guinle Teaching Hospital (HUGG) of the Federal University of Rio de Janeiro State (UNIRIO) were screened with Multiprobe T FISH after normal high resolution karyotyping. No subtelomeric rearrangements were detected even though the clinical score of the patients ranged from four to seven. Conclusion In developing countries, FISH-based techniques such as Multiprobe T FISH are still expensive. Although Multiprobe T FISH is a good tool for detecting STR, in this study it did not detect STR in patients with unexplained MR/developmental delay even though these patients had a marked chromosomal imbalance. Our findings also show that clinical scores are not reliable predictors of STR. PMID:23259705

  8. Characterization of Tumor Cells Using a Medical Wire for Capturing Circulating Tumor Cells: A 3D Approach Based on Immunofluorescence and DNA FISH

    PubMed Central

    Gallerani, Giulia; Cocchi, Claudia; Bocchini, Martine; Piccinini, Filippo; Fabbri, Francesco

    2017-01-01

    Circulating tumor cells (CTCs) are associated with poor survival in metastatic cancer. Their identification, phenotyping, and genotyping could lead to a better understanding of tumor heterogeneity and thus facilitate the selection of patients for personalized treatment. However, this is hampered because of the rarity of CTCs. We present an innovative approach for sampling a high volume of the patient blood and obtaining information about presence, phenotype, and gene translocation of CTCs. The method combines immunofluorescence staining and DNA fluorescent-in-situ-hybridization (DNA FISH) and is based on a functionalized medical wire. This wire is an innovative device that permits the in vivo isolation of CTCs from a large volume of peripheral blood. The blood volume screened by a 30-min administration of the wire is approximately 1.5-3 L. To demonstrate the feasibility of this approach, epithelial cell adhesion molecule (EpCAM) expression and the chromosomal translocation of the ALK gene were determined in non-small-cell lung cancer (NSCLC) cell lines captured by the functionalized wire and stained with an immuno-DNA FISH approach. Our main challenge was to perform the assay on a 3D structure, the functionalized wire, and to determine immuno-phenotype and FISH signals on this support using a conventional fluorescence microscope. The results obtained indicate that catching CTCs and analyzing their phenotype and chromosomal rearrangement could potentially represent a new companion diagnostic approach and provide an innovative strategy for improving personalized cancer treatments. PMID:29286485

  9. Proposed methods and endpoints for defining and assessing adverse environmental impact (AEI) on fish communities/populations in Tennessee River reservoirs.

    PubMed

    Hickman, Gary D; Brown, Mary L

    2002-06-07

    Two multimetric indices have been developed to help address fish community (reservoir fish assemblage index [RFAI]) and individual population quality (sport fishing index [SFI]) in Tennessee River reservoirs. The RFAI, with characteristics similar to the index of biotic integrity (IBI) used in stream fish community determinations, was developed to monitor the existing condition of resident fish communities. The index, which incorporates standardized electrofishing of littoral areas and experimental gill netting for limnetic bottom-dwelling species, has been used to determine residential fish community response to various anthropogenic impacts in southeastern reservoirs. The SFI is a multimetric index designed to address the quality of the fishery for individual resident sport fish species in a particular lake or reservoir[4]. The SFI incorporates measures of fish population aspects and angler catch and pressure estimates. This paper proposes 70% of the maximum RFAI score and 10% above the average SFI score for individual species as "screening" endpoints for balanced indigenous populations (BIP) or adverse environmental impact (AEI). Endpoints for these indices indicate: (1) communities/populations are obviously balanced indigenous populations (BIP) indicating no adverse environmental impact (AEI), or are "screened out"; (2) communities/populations are considered to be potentially impacted; and (3) where the resident fish community/population should be considered adversely impacted. Suggestions are also made concerning how examination of individual metric scores can help determine the source or cause of the impact.

  10. Medical devices; hematology and pathology devices; classification of early growth response 1 gene fluorescence in-situ hybridization test system for specimen characterization. Final order.

    PubMed

    2014-09-03

    The Food and Drug Administration (FDA) is classifying early growth response 1 (EGR1) gene fluorescence in-situ hybridization (FISH) test system for specimen characterization into class II (special controls). The special controls that will apply to this device are identified in this order and will be part of the codified language for the early growth response 1 (EGR1) gene fluorescence in-site hybridization (FISH) test system for specimen characterization classification. The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device.

  11. Filter-Adapted Fluorescent In Situ Hybridization (FA-FISH) for Filtration-Enriched Circulating Tumor Cells.

    PubMed

    Oulhen, Marianne; Pailler, Emma; Faugeroux, Vincent; Farace, Françoise

    2017-01-01

    Circulating tumor cells (CTCs) may represent an easily accessible source of tumor material to assess genetic aberrations such as gene-rearrangements or gene-amplifications and screen cancer patients eligible for targeted therapies. As the number of CTCs is a critical parameter to identify such biomarkers, we developed fluorescent in situ hybridization (FISH) for CTCs enriched on filters (filter-adapted-FISH, FA-FISH). Here, we describe the FA-FISH protocol, the combination of immunofluorescent staining (DAPI/CD45) and FA-FISH techniques, as well as the semi-automated microscopy method that we developed to improve the feasibility and reliability of FISH analyses in filtration-enriched CTC.

  12. The role of immunohistochemical analysis in the evaluation of EML4-ALK gene rearrangement in lung cancer.

    PubMed

    Sullivan, Harold C; Fisher, Kevin E; Hoffa, Anne L; Wang, Jason; Saxe, Debra; Siddiqui, Momin T; Cohen, Cynthia

    2015-04-01

    Among the mutations described in non-small cell lung carcinoma is a rearrangement resulting from an inversion within chromosome 2p leading to the formation of a fusion gene, echinoderm microtubule-associated protein-like 4-anaplastic lymphoma kinase (EML4-ALK). Fluorescence in situ hybridization (FISH) is the gold standard for the detection of ALK gene rearrangements. However, molecular methods are not readily available in all pathology laboratories. Immunohistochemistry (IHC) using an antibody directed against the EML4-ALK fusion protein provides a widely available alternative method of detection. We assessed whether IHC is a comparable and cost-effective alternative to FISH analysis for the detection of ALK gene rearrangements. A total of 110 non-small cell lung carcinoma cases (63 surgical/biopsy and 47 cytology specimens), previously tested for ALK gene rearrangements by FISH [7 (6.4%) positive for the rearrangement], were probed for the EML4-ALK fusion protein using a monoclonal EML4-ALK antibody, clone 5A4. Cells were considered to stain positive for ALK if >5% of cells showed cytoplasmic staining of at least grade 1 intensity (scale: 0 to 3). A cost analysis was performed using ALK IHC as a screening test. The sensitivity and specificity of the EML4-ALK IHC stain compared with ALK FISH analysis were 100% and 96%, respectively. All 7 FISH-positive cases stained positive by IHC, whereas 4 FISH-negative cases demonstrated positive staining. One of the 4 FISH-negative, IHC-positive cases harbored an EML4-ALK rearrangement by RT-PCR yielding 3 false-positive results overall. The κ agreement between IHC and FISH methods is 0.76 (substantial/excellent). The potential savings of implementing the ALK IHC as a screening method would be $10,418.21. Sensitivity of the EML4-ALK IHC stain is excellent (100%) but due to its suboptimal specificity, IHC cannot reliably supplant FISH analysis for the detection of ALK gene rearrangements. IHC shows promise as a screening tool to prevent unnecessary costly FISH analysis.

  13. Tuneable surface enhanced Raman spectroscopy hyphenated to chemically derivatized thin-layer chromatography plates for screening histamine in fish.

    PubMed

    Xie, Zhengjun; Wang, Yang; Chen, Yisheng; Xu, Xueming; Jin, Zhengyu; Ding, Yunlian; Yang, Na; Wu, Fengfeng

    2017-09-01

    Reliable screening of histamine in fish was of urgent importance for food safety. This work presented a highly selective surface enhanced Raman spectroscopy (SERS) method mediated by thin-layer chromatography (TLC), which was tailored for identification and quantitation of histamine. Following separation and derivatization with fluram, plates were assayed with SERS, jointly using silver nanoparticle and NaCl. The latter dramatically suppressed the masking effect caused by excessive fluram throughout the plate, thus offering clear baseline and intensive Raman fingerprints specific to the analyte. Under optimized conditions, the usability of this method was validated by identifying the structural fingerprints of both targeted and unknown compounds in fish samples. Meanwhile, the quantitative results of this method agreed with those by an HPLC method officially suggested by EU for histamine determination. Showing remarkable cost-efficiency and user-friendliness, this facile TLC-SERS method was indeed screening-oriented and may be more attractive to controlling laboratories of limited resource. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. A simple, fast and sensitive screening LC-ESI-MS/MS method for antibiotics in fish.

    PubMed

    Guidi, Letícia Rocha; Santos, Flávio Alves; Ribeiro, Ana Cláudia S R; Fernandes, Christian; Silva, Luiza H M; Gloria, Maria Beatriz A

    2017-01-15

    The objective of this study was to develop and validate a fast, sensitive and simple liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method for the screening of six classes of antibiotics (aminoglycosides, beta-lactams, macrolides, quinolones, sulfonamides and tetracyclines) in fish. Samples were extracted with trichloroacetic acid. LC separation was achieved on a Zorbax Eclipse XDB C18 column and gradient elution using 0.1% heptafluorobutyric acid in water and acetonitrile as mobile phase. Analysis was carried out in multiple reaction monitoring mode via electrospray interface operated in the positive ionization mode, with sulfaphenazole as internal standard. The method was suitable for routine screening purposes of 40 antibiotics, according to EC Guidelines for the Validation of Screening Methods for Residues of Veterinary Medicines, taking into consideration threshold value, cut-off factor, detection capability, limit of detection, sensitivity and specificity. Real fish samples (n=193) from aquaculture were analyzed and 15% were positive for enrofloxacin (quinolone), one of them at a higher concentration than the level of interest (50µgkg -1 ), suggesting possible contamination or illegal use of that antibiotic. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Interphase cytogenetics of prostatic carcinoma in fine needle aspirate smears of radical prostatectomy specimens: A practical screening tool?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, R.Y.; Troncoso, P.; El-Naggar, A.K.

    1994-09-01

    Identification of chromosomal aberrations that may be used for diagnostic or prognostic evaluation of prostatic adenocarcinoma has been the subject of great interest. In a previous study, we applied the fluorescence in situ hybridization (FISH) method on paraffin-embedded material to show that trisomy 7 was associated with the progression of human prostate cancer. In this study, we attempted to assess the utility of the FISH technique in detecting aneuploidy in fine needle aspirate (FNA) smears of prostatic tissues and to compare FISH results with that of DNA flow cytometry (FCM). Paired samples of normal and tumor FNA smears were obtainedmore » from 10 radical prostatectomy specimens. Dual-color chromosomes 7 and 9-specific centromeric DNA probes were used for FISH. FISH analysis demonstrated increased frequencies of trisomy 7 cells in all 10 tumors studied when compared with the paired normals. In contrast, 6 of 10 tumors were determined to be diploid by FCM. Our results show that FNA of radical prostatectomy specimens is a practical method for obtaining suitable material for both FISH and FCM analyses of prostate carcinoma. Thus, interphase FISH may be a practical screening tool to determine aneuploidy in FNA smears of prostatic carcinoma.« less

  16. COMPARISON OF AN IN VIVO FISH VTG ASSAY WITH YES AND E-SCREEN

    EPA Science Inventory

    This study compares the efficacy of two in vitro, estrogen-sensitive bioassays to rank the "relative estrogenicity" of five natural, pharmaceutical and xenoestrogens with a newly developed in vivo bioassay. The E-SCREEN (MCF-7 tumor cells) and YES (Yeast Estrogen Screen) assays w...

  17. Revisions of the Fish Invasiveness Screening Kit (FISK) for its application in warmer climatic zones, with particular reference to peninsular Florida.

    PubMed

    Lawson, Larry L; Hill, Jeffrey E; Vilizzi, Lorenzo; Hardin, Scott; Copp, Gordon H

    2013-08-01

    The initial version (v1) of the Fish Invasiveness Scoring Kit (FISK) was adapted from the Weed Risk Assessment of Pheloung, Williams, and Halloy to assess the potential invasiveness of nonnative freshwater fishes in the United Kingdom. Published applications of FISK v1 have been primarily in temperate-zone countries (Belgium, Belarus, and Japan), so the specificity of this screening tool to that climatic zone was not noted until attempts were made to apply it in peninsular Florida. To remedy this shortcoming, the questions and guidance notes of FISK v1 were reviewed and revised to improve clarity and extend its applicability to broader climatic regions, resulting in changes to 36 of the 49 questions. In addition, upgrades were made to the software architecture of FISK to improve overall computational speed as well as graphical user interface flexibility and friendliness. We demonstrate the process of screening a fish species using FISK v2 in a realistic management scenario by assessing the Barcoo grunter Scortum barcoo (Terapontidae), a species whose management concerns are related to its potential use for aquaponics in Florida. The FISK v2 screening of Barcoo grunter placed the species into the lower range of medium risk (score = 5), suggesting it is a permissible species for use in Florida under current nonnative species regulations. Screening of the Barcoo grunter illustrates the usefulness of FISK v2 as a proactive tool serving to inform risk management decisions, but the low level of confidence associated with the assessment highlighted a dearth of critical information on this species. © 2012 Society for Risk Analysis.

  18. The contribution of nearshore fish aggregating devices (FADs) to food security and livelihoods in Solomon Islands.

    PubMed

    Albert, Joelle A; Beare, Doug; Schwarz, Anne-Maree; Albert, Simon; Warren, Regon; Teri, James; Siota, Faye; Andrew, Neil L

    2014-01-01

    Fish aggregating devices, or FADs, are used widely in developing countries to concentrate pelagic fish, making them easier to catch. Nearshore FADs anchored close to the coast allow access for rural communities, but despite their popularity among policy makers, there is a dearth of empirical analysis of their contributions to the supply of fish and to fisheries management. In this paper we demonstrate that nearshore FADs increased the supply of fish to four communities in Solomon Islands. Estimated total annual fish catch ranged from 4300 to 12,000 kg across the study villages, with nearshore FADs contributing up to 45% of the catch. While it is clear that FADs increased the supply of fish, FAD catch rates were not consistently higher than other fishing grounds. Villages with limited access to diverse or productive fishing grounds seemingly utilized FADs to better effect. Villagers believed FADs increased household income and nutrition, as well as providing a source of fish for community events. FADs were also perceived to increase intra-household conflict and reduce fishers' participation in community activities. FADs need to be placed within a broader rural development context and treated as another component in the diversified livelihoods of rural people; as with other livelihood options they bring trade-offs and risks.

  19. The Contribution of Nearshore Fish Aggregating Devices (FADs) to Food Security and Livelihoods in Solomon Islands

    PubMed Central

    Albert, Joelle A.; Beare, Doug; Schwarz, Anne-Maree; Albert, Simon; Warren, Regon; Teri, James; Siota, Faye; Andrew, Neil L.

    2014-01-01

    Fish aggregating devices, or FADs, are used widely in developing countries to concentrate pelagic fish, making them easier to catch. Nearshore FADs anchored close to the coast allow access for rural communities, but despite their popularity among policy makers, there is a dearth of empirical analysis of their contributions to the supply of fish and to fisheries management. In this paper we demonstrate that nearshore FADs increased the supply of fish to four communities in Solomon Islands. Estimated total annual fish catch ranged from 4300 to 12 000 kg across the study villages, with nearshore FADs contributing up to 45% of the catch. While it is clear that FADs increased the supply of fish, FAD catch rates were not consistently higher than other fishing grounds. Villages with limited access to diverse or productive fishing grounds seemingly utilized FADs to better effect. Villagers believed FADs increased household income and nutrition, as well as providing a source of fish for community events. FADs were also perceived to increase intra-household conflict and reduce fishers' participation in community activities. FADs need to be placed within a broader rural development context and treated as another component in the diversified livelihoods of rural people; as with other livelihood options they bring trade-offs and risks. PMID:25513808

  20. Establishment and Usability Evaluation of an Interactive AR Learning System on Conservation of Fish

    ERIC Educational Resources Information Center

    Lin, Hao-Chiang Koong; Hsieh, Min-Chai; Wang, Cheng-Hung; Sie, Zong-Yuan; Chang, Shei-Hsi

    2011-01-01

    In this study, we develop an interactive AR Learning System based on Augmented Reality and interactive touch-screen. The learning content knowledge is about conservation of fish in Taiwan. The system combines the game by the concept of AR book which allows children to learn about the importance of conservation of fish. A mechanism is designed to…

  1. Simultaneous screening and confirmation of multiple classes of drug residues in fish by liquid chromatography-ion trap mass spectrometry.

    PubMed

    Smith, Shani; Gieseker, Charles; Reimschuessel, Renate; Decker, Christie-Sue; Carson, Mary C

    2009-11-13

    LC-ion trap mass spectrometry was used to screen and confirm 38 compounds from a variety of drug classes in four species of fish: trout, salmon, catfish, and tilapia. Samples were extracted with acetonitrile and hexane. The acetonitrile phase was evaporated, redissolved in water and acetonitrile, and analyzed by gradient chromatography on a phenyl column. MS(2) or MS(3) spectra were monitored for each compound. Qualitative method performance was evaluated by the analysis over several days of replicate samples of control fish, fish fortified with a drug mixture at 1 ppm, 0.1 ppm and 0.01 ppm, and fish dosed with a representative from each drug class. Half of the 38 drugs were confirmed at 0.01 ppm, the lowest fortification level. This included all of the quinolones and fluoroquinolones, the macrolides, malachite green, and most of the imidazoles. Florfenicol amine, metronidazole, sulfonamides, tetracyclines, and most of the betalactams were confirmed at 0.1 ppm. Ivermectin and penicillin G were only detectable in the 1 ppm fortified samples. With the exception of amoxicillin, emamectin, metronidazole, and tylosin, residue presence was confirmed in all the dosed fish.

  2. Developing an Apicomplexan DNA Barcoding System to Detect Blood Parasites of Small Coral Reef Fishes.

    PubMed

    Renoux, Lance P; Dolan, Maureen C; Cook, Courtney A; Smit, Nico J; Sikkel, Paul C

    2017-08-01

    Apicomplexan parasites are obligate parasites of many species of vertebrates. To date, there is very limited understanding of these parasites in the most-diverse group of vertebrates, actinopterygian fishes. While DNA barcoding targeting the eukaryotic 18S small subunit rRNA gene sequence has been useful in identifying apicomplexans in tetrapods, identification of apicomplexans infecting fishes has relied solely on morphological identification by microscopy. In this study, a DNA barcoding method was developed that targets the 18S rRNA gene primers for identifying apicomplexans parasitizing certain actinopterygian fishes. A lead primer set was selected showing no cross-reactivity to the overwhelming abundant host DNA and successfully confirmed 37 of the 41 (90.2%) microscopically verified parasitized fish blood samples analyzed in this study. Furthermore, this DNA barcoding method identified 4 additional samples that screened negative for parasitemia, suggesting this molecular method may provide improved sensitivity over morphological characterization by microscopy. In addition, this PCR screening method for fish apicomplexans, using Whatman FTA preserved DNA, was tested in efforts leading to a more simplified field collection, transport, and sample storage method as well as a streamlining sample processing important for DNA barcoding of large sample sets.

  3. Fish consumption and socio-economic factors among residents of Arkhangelsk city and the rural Nenets autonomous area.

    PubMed

    Petrenya, Natalia; Dobrodeeva, Liliya; Brustad, Magritt; Bichkaeva, Fatima; Menshikova, Elena; Lutfalieva, Gulnara; Poletaeva, Anna; Repina, Veronika; Cooper, Marie; Odland, Jon Øyvind

    2011-02-01

    The urban Russian and the rural Indigenous populations in the Russian European North have different lifestyles, living conditions and food supplies. The objective of this study was to investigate and compare fish consumption in relation to the socio-economic characteristics of 2 communities in Arkhangelsk County. A cross-sectional study. In total, 166 adults (83.1% women) from Arkhangelsk city and 134 adults (80.6% women) from the village of Nelmin-Nos (of which 88.9% are Indigenous people, Nenets), in the Nenets Autonomous Area (NAO), attended a health screening. The screening included a physical examination, blood sampling and a questionnaire. The populations studied had different socio-economic characteristics. In the rural NAO group, education levels were lower, the number of full-time employees was less, the percentage of persons with low monthly income was higher and the number of children per household was higher when compared to the Arkhangelsk group. The median total fish intake was 48.8 g/day for Arkhangelsk city and 27.1 g/day for Nelmin-Nos (p=0.009). Locally caught whitefish constituted a major part of the total fish consumption in Nelmin-Nos, while lean marine fish species were rarely eaten. Cod and cod-family fish species were often consumed by residents of Arkhangelsk city (p < 0.001). Fish consumption was positively related to monthly income. The frequency of fishing in the respondents from the Nelmin-Nos group predicted their fish consumption. Monthly income had a significant influence on fish intake in both study populations from Northern Russia. Fishing seems to be an important factor for predicting fish consumption in the residents of the rural NAO.

  4. Evaluation of two juvenile salmon collection devices at Cowlitz Falls Dam, Washington, 2014

    USGS Publications Warehouse

    Kock, Tobias J.; Liedtke, Theresa L.; Ekstrom, Brian K.; Hurst, William

    2015-01-01

    In an attempt to improve overall collection efficiency, Tacoma Power developed and tested a new device in 2014, called the Upper Riffe Lake Collector (URLC). The URLC was a floating device designed to collect fish as they moved downstream after passing through turbines at Cowlitz Falls Dam. The design of the URLC included a pontoon barge that supported a large net structure designed to funnel fish into a live box where they could be removed and transported downstream of dams on the Cowlitz River.

  5. Evaluation of lipid-containing semipermeable membrane devices for monitoring organochlorine contaminants in the Upper Mississippi river

    USGS Publications Warehouse

    Ellis, Geoffrey S.; Rostad, Colleen E.; Huckins, James N.; Schmitt, Christopher J.; MacCarthy, Patrick

    1995-01-01

    Organochlorine contaminants sequestered in lipid-containing semipermeable membrane devices (SPMDs) were compared to those found in tangential-flow ultrafilter permeates as part of a pilot study at 10 sites in the Upper Mississippi River system. Caged and feral fish from three primary sites were also analyzed for comparison. Concentrated organochlorine (OC) compounds were readily extracted from the SPMDs by dialysis into hexane, and samples were analyzed by gas chromatography-negative chemical ionization-mass spectrometry. Fish and water samples were processed by conventional methods. Reasonable agreement was found between analyte SPMD-derived water concentrations and measured values of ultrafilter permeates; however, concentrations of the same analytes in caged fish did not appear to be proportional to water concentrations derived from SPMDs and ultrafilter permeates. The greatest number of OC compounds was detected in SPMDs; fewer were detected in caged fish and feral fish.

  6. NASA Flexible Screen Propellant Management Device (PMD) Demonstration With Cryogenic Liquid

    NASA Technical Reports Server (NTRS)

    Wollen, Mark; Bakke, Victor; Baker, James

    2012-01-01

    While evaluating various options for liquid methane and liquid oxygen propellant management for lunar missions, Innovative Engineering Solutions (IES) conceived the flexible screen device as a potential simple alternative to conventional propellant management devices (PMD). An apparatus was designed and fabricated to test flexible screen devices in liquid nitrogen. After resolution of a number of issues (discussed in detail in the paper), a fine mesh screen (325 by 2300 wires per inch) spring return assembly was successfully tested. No significant degradation in the screen bubble point was observed either due to the screen stretching process or due to cyclic fatigue during testing. An estimated 30 to 50 deflection cycles, and approximately 3 to 5 thermal cycles, were performed on the final screen specimen, prior to and between formally recorded testing. These cycles included some "abusive" pressure cycling, where gas or liquid was driven through the screen at rates that produced differential pressures across the screen of several times the bubble point pressure. No obvious performance degradation or other changes were observed over the duration of testing. In summary, it is felt by the author that these simple tests validated the feasibility of the flexible screen PMD concept for use with cryogenic propellants.

  7. Accessibility of Mobile Devices for Visually Impaired Users: An Evaluation of the Screen-Reader VoiceOver.

    PubMed

    Smaradottir, Berglind; Håland, Jarle; Martinez, Santiago

    2017-01-01

    A mobile device's touchscreen allows users to use a choreography of hand gestures to interact with the user interface. A screen reader on a mobile device is designed to support the interaction of visually disabled users while using gestures. This paper presents an evaluation of VoiceOver, a screen reader in Apple Inc. products. The evaluation was a part of the research project "Visually impaired users touching the screen - a user evaluation of assistive technology".

  8. 9. Close view of gate valves (foreground), paddle wheel guard ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. Close view of gate valves (foreground), paddle wheel guard (midground), and water wheel (background), facing southeast (downstream) from drum screen cover. - Congdon Canal, Fish Screen, Naches River, Yakima, Yakima County, WA

  9. The continuous plankton recorder survey: A long-term, basin-scale oceanic time series

    NASA Technical Reports Server (NTRS)

    Gamble, John C.; Hunt, Harold G.

    1992-01-01

    In the 1920s, before the advent of echo sounders, fishery biologists were greatly concerned with assisting the fisherman to locate schools of pelagic fish. One of the approaches they developed was to relate the distribution of the planktonic food organisms to the presence of the schools of predators such as herring (Clupea harengus). The British planktologist, Alister Hardy, who had already carried out extensive studies on the feeding preferences of herring (Hardy, 1926a), initiated a program to examine the fishermen's contention that herring schools avoided 'green', i.e., phytoplankton-rich, water but could be correlated with high concentrations of zooplankton. This practical program was centered on the use of a specially developed instrument, the 'Plankton Indicator', designed to be used by the fisherman to assist in the search for suitable waters. It had limited success in its main aim but, as a collecting device, it embodied several profoundly important features. It was a simple instrument which was robust enough to be deployed and recovered by the crew of commercial vessels (in this case fishing vessels) while they were underway. The Indicator however, was no more than a high speed net which integrated the plankton over the area of sampling, but Hardy had also become interested in describing the patchiness of planktonic populations. He thus developed the Continuous Plankton Recorder (CPR) where he substituted the fixed filter screen of the Indicator by a continually moving length of silk mesh. The screen traversed at constant speed across the path of the incoming water and the trapped organisms were retained in place by sandwiching beneath an additional second mesh screen. Thus, knowing the speed of the towing vessel and the shooting and hauling positions, the spatial patterns of the plankton could be determined. Hardy took the first CPR to the Antarctic where he used it in the Southern Atlantic (Hardy, 1926b) and later deployed it in the North Sea to make some of the earliest contiguous records of plankton patchiness.

  10. Screen Channel Liquid Acquisition Devices for Cryogenic Propellants

    NASA Technical Reports Server (NTRS)

    Chato, David J.; Kudlac, Maureen T.

    2005-01-01

    This paper describes an on-going project to study the application screen channel liquid acquisition devices to cryogenic propellant systems. The literature of screen liquid acquisition devices is reviewed for prior cryogenic experience. Test programs and apparatus are presented to study these devices. Preliminary results are shown demonstrating bubble points for 200 x 1400 wires per inch and 325 x 2300 wires per inch Dutch twill screens. The 200 x 1400 screen has a bubble point of 15.8 inches of water in isopropyl alcohol and 6.6 inches of water in liquid nitrogen. The 325 x 2300 screen has a bubble point of 24.5 inches of water in isopropyl alcohol, 10.7 inches of water in liquid nitrogen, and 1.83 inches of water in liquid hydrogen. These values are found to be in good agreement with the results reported in the literature.

  11. Association between screen viewing duration and sleep duration, sleep quality, and excessive daytime sleepiness among adolescents in Hong Kong.

    PubMed

    Mak, Yim Wah; Wu, Cynthia Sau Ting; Hui, Donna Wing Shun; Lam, Siu Ping; Tse, Hei Yin; Yu, Wing Yan; Wong, Ho Ting

    2014-10-28

    Screen viewing is considered to have adverse impacts on the sleep of adolescents. Although there has been a considerable amount of research on the association between screen viewing and sleep, most studies have focused on specific types of screen viewing devices such as televisions and computers. The present study investigated the duration with which currently prevalent screen viewing devices (including televisions, personal computers, mobile phones, and portable video devices) are viewed in relation to sleep duration, sleep quality, and daytime sleepiness among Hong Kong adolescents (N = 762). Television and computer viewing remain prevalent, but were not correlated with sleep variables. Mobile phone viewing was correlated with all sleep variables, while portable video device viewing was shown to be correlated only with daytime sleepiness. The results demonstrated a trend of increase in the prevalence and types of screen viewing and their effects on the sleep patterns of adolescents.

  12. Microbial detection in microfluidic devices through dual staining of quantum dots-labeled immunoassay and RNA hybridization.

    PubMed

    Zhang, Qing; Zhu, Liang; Feng, Hanhua; Ang, Simon; Chau, Fook Siong; Liu, Wen-Tso

    2006-01-18

    This paper reported the development of a microfludic device for the rapid detection of viable and nonviable microbial cells through dual labeling by fluorescent in situ hybridization (FISH) and quantum dots (QDs)-labeled immunofluorescent assay (IFA). The coin sized device consists of a microchannel and filtering pillars (gap=1-2 microm) and was demonstrated to effectively trap and concentrate microbial cells (i.e. Giardia lamblia). After sample injection, FISH probe solution and QDs-labeled antibody solution were sequentially pumped into the device to accelerate the fluorescent labeling reactions at optimized flow rates (i.e. 1 and 20 microL/min, respectively). After 2 min washing for each assay, the whole process could be finished within 30 min, with minimum consumption of labeling reagents and superior fluorescent signal intensity. The choice of QDs 525 for IFA resulted in bright and stable fluorescent signal, with minimum interference with the Cy3 signal from FISH detection.

  13. The fluorescence theatre: a cost-effective device using theatre gels for fluorescent protein and dye screening.

    PubMed

    Heil, John R; Nordeste, Ricardo F; Charles, Trevor C

    2011-04-01

    Here we report a simple cost-effective device for screening colonies on plates for expression of the monomeric red fluorescent protein mRFP1 and the fluorescent dye Nile red. This device can be built from any simple light source, in our case a Quebec Colony Counter, and cost-effective theatre gels. The device can be assembled in as little as 20 min, and it produces excellent results when screening a large number of colonies.

  14. Bioaccumulation of PCB Contaminants in Five Fish Species in Utah Lake as Affected by Carp Removal

    NASA Astrophysics Data System (ADS)

    Sanjinez-Guzmán, V. A.; Cadet, E. L.; Crandall, T.; Chamberlain, T.; Rakotoarisaona, H.; Morris, P.

    2017-12-01

    State reports published by the Utah Department of Health (2005) and the Utah Department of Water Quality (2008) determined that there were elevated levels of PCBs (Polychlorinated biphenyls) that exceeded the EPA's cancer (0.02 𝑚𝑔 𝑘𝑔-1) and non-cancer screening levels (0.08 𝑚𝑔 𝑘𝑔-1) in two fish species from Utah Lake, the Common Carp (Cyprinus carpio) and the Channel Catfish (Ictalurus punctatus). Fish consumption advisories were issued for both of these fish species due to their health effects of PCBs. The Common Carp is a non-native predatory species that comprise 90% of the biomass in Utah Lake. As of September 2009, an extensive carp removal program was instituted by the Department of Natural Resources and began the removal of 75% of the carp population. The purpose of this study is to assess the impact of carp removal on PCB levels in five sport fish species consumed by Utah citizens. The fish being analyzed are the Common Carp (Cyprinus carpio), Channel Catfish (Ictalurus punctatus), Black Bullhead (Ameiurus melas), Walleye (Sander vitreus), and White Bass (Morone chrysops). One-hundred twenty (120) fish were collected from Utah Lake and subcategorized by their gender, tissue type (fillet and offal), weight, and size: small (under 33 cm), medium (33 cm - 43 cm), and large (greater than 43 cm). This was done in order to determine the variation of contaminant levels in each subcategory. PCB analysis was performed by Utility Testing Laboratory in Salt Lake City, Utah. Results show there has been a significant increase in PCB levels in all fish species in comparison with the state reports (2008). All fish species have exceeded the EPA cancer screening level, except for the fillet tissue of the White Bass species. In Common Carp fillet, and offal decreased concentrations of 11.80% and 23.72%, respectively. In Channel catfish: the PCB levels in the fillet increase by 87.93%, however, the offal levels decrease by 5.16%. In Black Bullhead catfish: both fillet and offal increase by large amounts (5464.37% and 1047.46%, respectively). Elevated levels that surpass the EPA cancer screening level have been found in all fish, except for the fillet tissue of the White Bass species. These results indicate that fish investigated in this study may not be safe for human consumption.

  15. National Dam Inspection Program. Lake Catalpa Dam (NDS-ID Number PA-560), (DER-ID Number 40-57) Susquehanna River Basin, Falls Creek, Luzerne County, Pennsylvania. Phase I Inspection Report,

    DTIC Science & Technology

    1980-09-01

    Ogee spillway crest 1269.5 Sharp crest weir (rigid fish screen) 1271.5 N Upstream invert of spillway 1265.4 Downstream invert of spillway 1260.9 Maximum...Sluice gate Access Valve house upstream Regulating facilities Sluice gate i. Spillway. Type Concrete ogee to sharp crested weir Length 26 feet Ogee... crest elevation 1269.5 Sharp crest weir (rigid fish screen) 1271.5 Upstream channel Lake Downstream channel Reinforced concrete channel for

  16. Effect of transient liquid flow on retention characteristics of screen acquisition systems. [design of Space Shuttle feed system

    NASA Technical Reports Server (NTRS)

    Cady, E. C.

    1977-01-01

    A design analysis, is developed based on experimental data, to predict the effects of transient flow and pressure surges (caused either by valve or pump operation, or by boiling of liquids in warm lines) on the retention performance of screen acquisition systems. A survey of screen liquid acquisition system applications was performed to determine appropriate system environment and classification. A screen model was developed which assumed that the screen device was a uniformly distributed composite orthotropic structure, and which accounted for liquid inflow/outflow, gas ingestion quality, screen stress, and liquid spill. A series of 177 tests using 13 specimens (5 screen meshes, 4 screen device construction/backup methods, and 2 orientations) with three test fluids (isopropyl alcohol, Freon 114, and LH2) provided data which verified important features of the screen model and resulted in a design tool which could accurately predict the transient startup performance acquisition devices.

  17. User's guide to FBASE: Relational database software for managing R1/R4 (Northern/Intermountain Regions) fish habitat inventory data

    Treesearch

    Sherry P. Wollrab

    1999-01-01

    FBASE is a microcomputer relational database package that handles data collected using the R1/R4 Fish and Fish Habitat Standard Inventory Procedures (Overton and others 1997). FBASE contains standard data entry screens, data validations for quality control, data maintenance features, and summary report options. This program also prepares data for importation into an...

  18. SMALL FISH MODELS FOR IDENTIFYING AND ASSESSING THE EFFECTS OF ENDOCRINE DISRUPTING CHEMICALS

    EPA Science Inventory

    Endocrine-disrupting chemicals (EDCs), in particular those which affect the hypothalamic-pituitary-gonadal (HPG) axis of vertebrates, have become a focus of regulatory screening and testing throughout the world. Small fish species, principally the fathead minnow (Pimephales prom...

  19. Contaminant levels in fish tissue from San Francisco Bay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fairey, R.; Taberski, K.

    1995-12-31

    Edible fish species were collected from thirteen locations throughout San Francisco Bay, during the spring of 1994, for determination of contaminants levels in muscle tissue. Species collected included white croaker, surfperch, leopard and brown smoothhound sharks, striped bass, white sturgeon and halibut Sixty six composite tissue samples were analyzed for the presence of PAHs, PCBs, pesticides, trace elements and dioxin/furans. The US EPA approach to assessing chemical contaminant data for fish tissue consumption was used for identifying the primary chemicals of concern. Six chemicals or chemical groups were found to exceed screening levels established using the US EPA approach. PCBsmore » (as total Aroclors) exceeded the screening level of 3 ppb in all sixty six tissue samples, with the highest concentrations (638 ppb) found near San Francisco`s industrial areas. Mercury was elevated (> 0.14 ppm) in forty of the sixty-six samples with the highest levels (1.26 ppm) occurring in shark muscle tissues. Concentrations of the organochlorine pesticides dieldrin, total chlordanes and total DDTs exceeded screening levels in a number of samples. Dioxin/furans (as TEQs) were elevated (above 0.15 ppt) in 16 of the 19 samples analyzed. Fish with high lipid content (croaker and surfperch) in their muscle tissue generally exhibited higher contaminant levels while fish with low lipid levels (halibut and shark) exhibited lower organic contaminant levels. Tissue samples taken from North Bay stations most often exhibited high levels of chemical contamination. The California Office of Health Hazard Assessment is currently evaluating the results of this study and has issued an interim Health Advisory concerning the human consumption of fish tissue from San Francisco Bay.« less

  20. Application of the BAX for screening/genus Listeria polymerase chain reaction system for monitoring Listeria species in cold-smoked fish and in the smoked fish processing environment.

    PubMed

    Norton, D M; McCamey, M; Boor, K J; Wiedmann, M

    2000-03-01

    The cold-smoked fish industry was used as a model for the development of a system for monitoring Listeria spp. in foods and in the food processing environment. A total of 214 samples including raw fish, fish during the cold-smoking process, finished product, and environmental samples were collected from three processing facilities over two visits to each facility. Samples were screened for Listeria spp. using the BAX for Screening/genus Listeria polymerase chain reaction system (PCR) and by culture. Listeria spp., confirmed by the API Listeria test strip or by a PCR assay targeting the L. monocytogenes hlyA gene, were isolated from a total of 89 (41.6%) samples. Of these, 80 samples also tested positive for Listeria spp. using the BAX system. Specifically, 42 (55.3%) environmental samples (n = 76), 11 (25.6%) raw materials samples (n = 43), 20 (35.1%) samples from fish in various stages of processing (n = 57), and 7 (18.4%) finished product samples (n = 38) tested positive for Listeria spp. using the BAX system. Five (4.0%) of the 125 culture-negative samples yielded BAX system-positive results. Listeria isolates from each of nine culture-positive/BAX system-negative samples yielded a positive reaction when tested in pure culture by the BAX system, suggesting that our false-negative results were likely due to the presence of low Listeria numbers in the initial enrichment as opposed to nonreacting isolates. The employment of alternative enrichment protocols, such as the two-step enrichment recommended by the manufacturer, may increase the sensitivity of the assay.

  1. ScreenCube: A 3D Printed System for Rapid and Cost-Effective Chemical Screening in Adult Zebrafish.

    PubMed

    Monstad-Rios, Adrian T; Watson, Claire J; Kwon, Ronald Y

    2018-02-01

    Phenotype-based small molecule screens in zebrafish embryos and larvae have been successful in accelerating pathway and therapeutic discovery for diverse biological processes. Yet, the application of chemical screens to adult physiologies has been relatively limited due to additional demands on cost, space, and labor associated with screens in adult animals. In this study, we present a 3D printed system and methods for intermittent drug dosing that enable rapid and cost-effective chemical administration in adult zebrafish. Using prefilled screening plates, the system enables dosing of 96 fish in ∼3 min, with a 10-fold reduction in drug quantity compared to that used in previous chemical screens in adult zebrafish. We characterize water quality kinetics during immersion in the system and use these kinetics to rationally design intermittent dosing regimens that result in 100% fish survival. As a demonstration of system fidelity, we show the potential to identify two known chemical inhibitors of adult tail fin regeneration, cyclopamine and dorsomorphin. By developing methods for rapid and cost-effective chemical administration in adult zebrafish, this study expands the potential for small molecule discovery in postembryonic models of development, disease, and regeneration.

  2. Effects of a Novel Fish Transport System on the Health of Adult Fall Chinook Salmon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geist, David R.; Colotelo, Alison H.; Linley, Timothy J.

    Movement past hydroelectric dams and related in-river structures has important implications for habitat connectivity and population persistence in migratory fish. A major problem is that many of these structures lack effective fish passage facilities, which can fragment spawning and rearing areas and negatively impact recruitment. While traditional fish passage facilities (e.g., ladders, trap and haul) can effectively enable fish to pass over barriers, their capital or operational costs can be significant. We evaluated the utility of a novel transport device that utilizes a flexible tube with differential internal air pressure to pass fish around in-river barriers. Three treatments and amore » control group were tested. In two of the treatments, adult fall Chinook Salmon nearing maturation were transported through the device via two lengths of tube (12 or 77 m) and their injury, stress, and immune system responses and reproductive function were compared to a third treatment where fish were moved by a standard trap and haul method and also to a control group. We observed no significant differences among the treatment or control groups in post-treatment adult survival, injury or stress. Indicators of immune system response and reproductive readiness were also not significantly different among the four groups. Egg survival was significantly different among the groups, but the differences were highly variable within groups and not consistent with the duration of treatment or degree of handling. Taken together, the results suggest the device did not injure or alter normal physiological functioning of adult fall Chinook Salmon nearing maturation and may provide an effective method for transporting such fish around in-river barriers during their spawning migration. Keywords: Whooshh, transport, in-stream barriers, hydropower« less

  3. Power spectrum analysis for defect screening in integrated circuit devices

    DOEpatents

    Tangyunyong, Paiboon; Cole Jr., Edward I.; Stein, David J.

    2011-12-01

    A device sample is screened for defects using its power spectrum in response to a dynamic stimulus. The device sample receives a time-varying electrical signal. The power spectrum of the device sample is measured at one of the pins of the device sample. A defect in the device sample can be identified based on results of comparing the power spectrum with one or more power spectra of the device that have a known defect status.

  4. A Simultaneous Genetic Screen for Zygotic and Sterile Mutants in a Hermaphroditic Vertebrate (Kryptolebias marmoratus)

    PubMed Central

    Sucar, Sofia; Moore, Ginger L.; Ard, Melissa E.; Ring, Brian C.

    2016-01-01

    The mangrove killifish, Kryptolebias marmoratus, is unique among vertebrates due to its self-fertilizing mode of reproduction involving an ovotestis. As a result, it constitutes a simplistic and desirable vertebrate model for developmental genetics as it is easily maintained, reaches sexual maturity in about 100 days, and provides a manageable number of relatively clear embryos. After the establishment and characterization of an initial mutagenesis pilot screen using N-ethyl-N-nitrosourea, a three-generation genetic screen was performed to confirm zygotic mutant allele heritability and simultaneously score for homozygous recessive mutant sterile F2 fish. From a total of 307 F2 fish screened, 10 were found to be 1° males, 16 were sterile, 92 wild-type, and the remaining 189, carriers of zygotic recessive alleles. These carriers produced 25% progeny exhibiting several zygotic phenotypes similar to those previously described in zebrafish and in the aforementioned pilot screen, as expected. Interestingly, new phenotypes such as golden yolk, no trunk, and short tail were observed. The siblings of sterile F2 mutants were used to produce an F3 generation in order to confirm familial sterility. Out of the 284 F3 fish belonging to 10 previously identified sterile families, 12 were found to be 1° males, 69 were wild-type, 83 sterile, and 120 were classified as */+ (either wild-type or carriers) with undefined genotypes. This screen provides proof of principle that K. marmoratus is a powerful vertebrate model for developmental genetics and can be used to identify mutations affecting fertility. PMID:26801648

  5. Development of a National-Scale Fish Contaminant Indicator for the National Coastal Assessment

    EPA Science Inventory

    Transforming measurable concentrations of chemicals found in whole-body fish and shellfish into an ecologically relevant indicator is not easily accomplished since few pertinent biologically protective contaminant-screening tools exist, and none have been published for use at a n...

  6. Comparison of analytical methods for the determination of histamine in reference canned fish samples

    NASA Astrophysics Data System (ADS)

    Jakšić, S.; Baloš, M. Ž.; Mihaljev, Ž.; Prodanov Radulović, J.; Nešić, K.

    2017-09-01

    Two screening methods for histamine in canned fish, an enzymatic test and a competitive direct enzyme-linked immunosorbent assay (CD-ELISA), were compared with the reversed-phase liquid chromatography (RP-HPLC) standard method. For enzymatic and CD-ELISA methods, determination was conducted according to producers’ manuals. For RP-HPLC, histamine was derivatized with dansyl-chloride, followed by RP-HPLC and diode array detection. Results of analysis of canned fish, supplied as reference samples for proficiency testing, showed good agreement when histamine was present at higher concentrations (above 100 mg kg-1). At a lower level (16.95 mg kg-1), the enzymatic test produced some higher results. Generally, analysis of four reference samples according to CD-ELISA and RP-HPLC showed good agreement for histamine determination (r=0.977 in concentration range 16.95-216 mg kg-1) The results show that the applied enzymatic test and CD-ELISA appeared to be suitable screening methods for the determination of histamine in canned fish.

  7. A Strategy of Suppressing the Underground Impact Scattered Current in Power Grid by Using Insulation Baffle

    NASA Astrophysics Data System (ADS)

    Zhan, Qinghua; Chen, Zhucheng; Li, Hongtao; Liu, Yijun; Mei, Cheng; He, Zhijie

    2017-05-01

    In order to solve the accidents happened in the ponds or other special places around the tower which were caused by the diffusion current after lightning stroke the transmission tower, the protection measures for the problem tower in the area of Guangdong Province which occurred dead fish in the pond in thunderstorm weather were studied in this paper. The COMSOL mutiphysics simulation software was used in order to calculate the electromagnetic environment of the diffusion situation by grounding device after lightning stroke the power transmission tower. Study concluded that the safe distance between the fish pond and grounding device of transmission tower is 14 meter. The effects of the length and depth or stayed a gap of the insulation baffle on the fish in the fish pond were discussed. The protection method of the insulation baffle has important practical significance to the protection of the grounding device for diffusion current, and can provide some engineering guidance and basis for the grounding arrangement and transformation of the high voltage transmission line tower.

  8. ALK ambiguous-positive non-small cell lung cancers are tumors challenged by diagnostic and therapeutic issues.

    PubMed

    Uguen, Arnaud; Andrieu-Key, Sophie; Vergne, Florence; Descourt, Renaud; Quéré, Gilles; Quintin-Roué, Isabelle; Key, Stéphane; Guéguen, Paul; Talagas, Matthieu; De Braekeleer, Marc; Marcorelles, Pascale

    2016-09-01

    Searching for ALK rearrangements using the approved fluorescent in situ hybridization (FISH) test and complementary immunohistochemistry (IHC) has become the rule to treat patients with advanced non‑small cell lung cancer (NSCLC) with anti‑ALK targeted therapy. The concordance between the two techniques is reported to be strong but imperfect. We report our experience with cases of ALK‑rearranged lung adenocarcinomas pointing out particularly ambiguous cases. FISH and IHC data on ALK but also c‑MET IHC as well as EGFR and KRAS mutation screening are considered, together with response to crizotinib treatment. We classified the 55 FISH ALK‑rearranged tumors into two groups according to the FISH and IHC results: a concordant FISH+IHC+ group (31 tumors) and an ambiguous group (24 tumors). These tumors were considered as 'ambiguous' ALK‑positive due to negative (21 tumors) or non‑contributive (3 tumors) IHC. In addition, the percentage of FISH-positive nuclei was between 15 and 20% in 17 tumors belonging to one or the other group (now called borderline tumors). We discuss the accuracy of the different tests with intent to determine whether ambiguous and borderline tumors are real positive ALK‑rearranged tumors. To conclude, ambiguous ALK‑positive lung cancers are challenging tumors with diagnosis and therapeutic issues that can justify parallel FISH, IHC and molecular screening strategy.

  9. Behavorial assessments of larval zebrafish neurotoxicology

    EPA Science Inventory

    Fishes have long been a popular organism in ecotoxicology research, and are increasingly used in human health research as an alternative animal model for chemical screening. Our laboratory incorporates a zebrafish (Danio rerio) embryo/larval assay to screen chemicals for developm...

  10. Nontargeted Screening Method for Illegal Additives Based on Ultrahigh-Performance Liquid Chromatography-High-Resolution Mass Spectrometry.

    PubMed

    Fu, Yanqing; Zhou, Zhihui; Kong, Hongwei; Lu, Xin; Zhao, Xinjie; Chen, Yihui; Chen, Jia; Wu, Zeming; Xu, Zhiliang; Zhao, Chunxia; Xu, Guowang

    2016-09-06

    Identification of illegal additives in complex matrixes is important in the food safety field. In this study a nontargeted screening strategy was developed to find illegal additives based on ultrahigh-performance liquid chromatography-high-resolution mass spectrometry (UHPLC-HRMS). First, an analytical method for possible illegal additives in complex matrixes was established including fast sample pretreatment, accurate UHPLC separation, and HRMS detection. Second, efficient data processing and differential analysis workflow were suggested and applied to find potential risk compounds. Third, structure elucidation of risk compounds was performed by (1) searching online databases [Metlin and the Human Metabolome Database (HMDB)] and an in-house database which was established at the above-defined conditions of UHPLC-HRMS analysis and contains information on retention time, mass spectra (MS), and tandem mass spectra (MS/MS) of 475 illegal additives, (2) analyzing fragment ions, and (3) referring to fragmentation rules. Fish was taken as an example to show the usefulness of the nontargeted screening strategy, and six additives were found in suspected fish samples. Quantitative analysis was further carried out to determine the contents of these compounds. The satisfactory application of this strategy in fish samples means that it can also be used in the screening of illegal additives in other kinds of food samples.

  11. Content analysis of Australian direct-to-consumer websites for emerging breast cancer imaging devices.

    PubMed

    Vreugdenburg, Thomas D; Laurence, Caroline O; Willis, Cameron D; Mundy, Linda; Hiller, Janet E

    2014-09-01

    To describe the nature and frequency of information presented on direct-to-consumer websites for emerging breast cancer imaging devices. Content analysis of Australian website advertisements from 2 March 2011 to 30 March 2012, for three emerging breast cancer imaging devices: digital infrared thermal imaging, electrical impedance scanning and electronic palpation imaging. Type of imaging offered, device safety, device performance, application of device, target population, supporting evidence and comparator tests. Thirty-nine unique Australian websites promoting a direct-to-consumer breast imaging device were identified. Despite a lack of supporting evidence, 22 websites advertised devices for diagnosis, 20 advertised devices for screening, 13 advertised devices for prevention and 13 advertised devices for identifying breast cancer risk factors. Similarly, advertised ranges of diagnostic sensitivity (78%-99%) and specificity (44%-91%) were relatively high compared with published literature. Direct comparisons with conventional screening tools that favoured the new device were highly prominent (31 websites), and one-third of websites (12) explicitly promoted their device as a suitable alternative. Australian websites for emerging breast imaging devices, which are also available internationally, promote the use of such devices as safe and effective solutions for breast cancer screening and diagnosis in a range of target populations. Many of these claims are not supported by peer-reviewed evidence, raising questions about the manner in which these devices and their advertising material are regulated, particularly when they are promoted as direct alternatives to established screening interventions.

  12. Screening method to evaluate point-of-care human chorionic gonadotropin (hCG) devices for susceptibility to the hook effect by hCG β core fragment: evaluation of 11 devices.

    PubMed

    Nerenz, Robert D; Song, Haowei; Gronowski, Ann M

    2014-04-01

    The predominant hCG variant in urine, hCG β core fragment (hCGβcf), has been demonstrated to cause false-negative results in qualitative point-of-care (POC) hCG devices. This is a major concern for healthcare professionals using POC pregnancy tests. We developed a screening method to evaluate qualitative POC hCG devices for their susceptibility to inhibition by hCGβcf. Using this method, we evaluated the performance of 11 commonly used devices. A wide range of purified hCG and hCGβcf concentrations were mixed and tested on 2 POC devices. By use of those results, a screening method was defined and 9 additional POC devices were evaluated. Two solutions containing (a) 500 pmol/L (171 IU/L) intact hCG with 0 pmol/L hCGβcf and (b) 500 pmol/L intact hCG with 500 000 pmol/L hCGβcf were used to screen all POC devices. The OSOM and Cen-Med Elite devices were found to be most susceptible to false-negative results due to hCGβcf. The BC Icon 20 and the Alere were the least susceptible. The remaining 7 were moderately affected. Devices that gave the strongest signal with hCGβcf alone were those that were least likely to show a hook effect. The screening method put forth here can be used by device users and manufacturers to evaluate POC devices for inhibition by hCGβcf. Of 11 devices evaluated, only 2 have been identified that exhibit minimal to no susceptibility to hCGβcf.

  13. Entiat 4Mile WELLs Completion Report, 2006.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Malinowksi, Richard

    2007-01-01

    The Entiat 4-mile Wells (Entiat 4-mile) project is located in the Entiat subbasin and will benefit Upper Columbia steelhead, spring Chinook and bull trout. The goal of this project is to prevent juvenile fish from being diverted into an out-of-stream irrigation system and to eliminate impacts due to the annual maintenance of an instream pushup dam. The objectives include eliminating a surface irrigation diversion and replacing it with two wells, which will provide Bonneville Power Administration (BPA) and the Bureau of Reclamation (Reclamation) with a Federal Columbia River Power System (FCRPS) BiOp metric credit of one. Wells were chosen overmore » a new fish screen based on biological benefits and costs. Long-term biological benefits are provided by completely eliminating the surface diversion and the potential for fish entrainment in a fish screen. Construction costs for a new fish screen were estimated at $150,000, which does not include other costs associated with implementing and maintaining a fish screening project. Construction costs for a well were estimated at $20,000 each. The diversion consisted of a pushup dam that diverted water into an off-channel pond. Water was then pumped into a pressurized system for irrigation. There are 3 different irrigators who used water from this surface diversion, and each has multiple water right claims totaling approximately 5 cfs. Current use was estimated at 300 gallons per minute (approximately 0.641 cfs). Some irrigated acreage was taken out of orchard production less than 5 years ago. Therefore, approximately 6.8 acre-feet will be put into the State of Washington Trust Water Right program. No water will be set aside for conservation savings. The construction of the two irrigation wells for three landowners was completed in September 2006. The Lower Well (Tippen/Wick) will produce up to 175 gpm while the Upper Well (Griffith) will produce up to 275 gpm during the irrigation season. The eight inch diameter wells were developed to a depth of 75 feet and 85 feet, respectively, and will be pumped with Submersible Turbine pumps. The irrigation wells have been fitted with new electric boxes and Siemens flowmeters (MAG8000).« less

  14. Lake Billy Shaw Operations and Maintenance, Final Annual Report 2000.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dodson, Guy; Pero, Vincent

    Lake Billy Shaw is a newly constructed earthen dam reservoir with a surface area of 430 acres. Construction on the dam and structures was complete in November of 1998. The fish screen structures were complete in December of 1998, with initial filling in May 1999. Upon initial filling, dam structures, monitoring wells, fish screen structures, and lake level were monitored daily, with recordings being taken three times/week. During June 1999 the water to the lake was turned off in order to complete additional construction work on the lake. This work included installation of culverts around the perimeter road, installation ofmore » boat launches, finish work on the spillway structure, pumphouse and well protection and planting 4 trees along the entrance to the boat launch area. The water was turned on again in late September 1999 with all structures having been checked, fish screens greased and maintained and well levels being monitored. In 2000 the Operations and Maintenance portion of the project began with monitoring of piezometers, water levels, biological monitoring, riparian plantings, protection of shorelines, and maintenance of structures and appurtances.« less

  15. The hypothalamic-pituitary-thyroid (HPT) axis in fish and its role in fish development and reproduction.

    PubMed

    Blanton, Michael L; Specker, Jennifer L

    2007-01-01

    Bony fishes represent the largest vertebrate class and are a very diverse animal group. This chapter provides a thorough review of the available scientific literature on the thyroid system in these important vertebrate animals. The molecular components of the hypothalamic-pituitary-thyroid (HPT) axis in this group correspond closely to those of mammals. The thyroid tissue in the fishes is organized as diffuse follicles, with a few exceptions, rather than as an encapsulated gland as is found in most other vertebrate species. The features of this diffuse tissue in fishes are reviewed with an emphasis on feedback relationships within the HPT axis, the molecular biology of the thyroid system in fishes, and comparisons versus the thyroid systems of other vertebrate taxa. A review of the role of thyroid hormone in fish development and reproduction is included. Available information about the HPT axis in fishes is quite detailed for some species and rather limited or absent in others. This review focuses on species that have been intensively studied for their value as laboratory models in assays to investigate disruption in normal function of the thyroid system. In addition, in vitro and in vivo assay methods for screening chemicals for their potential to interfere with the thyroid system are reviewed. It is concluded that there are currently no in vitro or in vivo assays in fish species that are sufficiently developed to warrant recommendation for use to efficiently screen chemicals for thyroid disruption. Methods are available that can be used to measure thyroid hormones, although our ability to interpret the causes and implications of potential alterations in T4 or T3 levels in fishes is nonetheless limited without further research.

  16. Evaluating the zebrafish embryo toxicity test for pesticide hazard screening.

    PubMed

    Glaberman, Scott; Padilla, Stephanie; Barron, Mace G

    2017-05-01

    Given the numerous chemicals used in society, it is critical to develop tools for accurate and efficient evaluation of potential risks to human and ecological receptors. Fish embryo acute toxicity tests are 1 tool that has been shown to be highly predictive of standard, more resource-intensive, juvenile fish acute toxicity tests. However, there is also evidence that fish embryos are less sensitive than juvenile fish for certain types of chemicals, including neurotoxicants. The utility of fish embryos for pesticide hazard assessment was investigated by comparing published zebrafish embryo toxicity data from pesticides with median lethal concentration 50% (LC50) data for juveniles of 3 commonly tested fish species: rainbow trout, bluegill sunfish, and sheepshead minnow. A poor, albeit significant, relationship (r 2  = 0.28; p < 0.05) was found between zebrafish embryo and juvenile fish toxicity when pesticides were considered as a single group, but a much better relationship (r 2  = 0.64; p < 0.05) when pesticide mode of action was factored into an analysis of covariance. This discrepancy is partly explained by the large number of neurotoxic pesticides in the dataset, supporting previous findings that commonly used fish embryo toxicity test endpoints are particularly insensitive to neurotoxicants. These results indicate that it is still premature to replace juvenile fish toxicity tests with embryo-based tests such as the Organisation for Economic Co-operation and Development Fish Embryo Acute Toxicity Test for routine pesticide hazard assessment, although embryo testing could be used with other screening tools for testing prioritization. Environ Toxicol Chem 2017;36:1221-1226. © 2016 SETAC. © 2016 SETAC.

  17. 50 CFR 648.148 - Special management zones.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Black Sea Bass Fishery § 648.148 Special management zones. The recipient of a U.S. Army Corps of... purposes of fishing may request that an area surrounding and including the site be designated by the MAFMC... fishing gear that are not compatible with the intent of the artificial reef or fish attraction device or...

  18. Association between Screen Viewing Duration and Sleep Duration, Sleep Quality, and Excessive Daytime Sleepiness among Adolescents in Hong Kong

    PubMed Central

    Mak, Yim Wah; Wu, Cynthia Sau Ting; Hui, Donna Wing Shun; Lam, Siu Ping; Tse, Hei Yin; Yu, Wing Yan; Wong, Ho Ting

    2014-01-01

    Screen viewing is considered to have adverse impacts on the sleep of adolescents. Although there has been a considerable amount of research on the association between screen viewing and sleep, most studies have focused on specific types of screen viewing devices such as televisions and computers. The present study investigated the duration with which currently prevalent screen viewing devices (including televisions, personal computers, mobile phones, and portable video devices) are viewed in relation to sleep duration, sleep quality, and daytime sleepiness among Hong Kong adolescents (N = 762). Television and computer viewing remain prevalent, but were not correlated with sleep variables. Mobile phone viewing was correlated with all sleep variables, while portable video device viewing was shown to be correlated only with daytime sleepiness. The results demonstrated a trend of increase in the prevalence and types of screen viewing and their effects on the sleep patterns of adolescents. PMID:25353062

  19. Preparation of Microkernel-Based Mesoporous (SiO2-CdTe-SiO2)@SiO2 Fluorescent Nanoparticles for Imaging Screening and Enrichment of Heat Shock Protein 90 Inhibitors from Tripterygium Wilfordii.

    PubMed

    Hu, Yue; Miao, Zhao-Yi; Zhang, Xiao-Jing; Yang, Xiao-Tong; Tang, Ying-Ying; Yu, Sheng; Shan, Chen-Xiao; Wen, Hong-Mei; Zhu, Dong

    2018-05-01

    The currently utilized ligand fishing for bioactive molecular screening from complex matrixes cannot perform imaging screening. Here, we developed a new solid-phase ligand fishing coupled with an in situ imaging protocol for the specific enrichment and identification of heat shock protein 90 (Hsp 90) inhibitors from Tripterygium wilfordii, utilizing a multiple-layer and microkernel-based mesoporous nanostructure composed of a protective silica coating CdTe quantum dot (QD) core and a mesoporous silica shell, i.e., microkernel-based mesoporous (SiO 2 -CdTe-SiO 2 )@SiO 2 fluorescent nanoparticles (MMFNPs) as extracting carries and fluorescent probes. The prepared MMFNPs showed a highly uniform spherical morphology, retention of fluorescence emission, and great chemical stability. The fished ligands by Hsp 90α-MMFNPs were evaluated via the preliminary bioactivity based on real-time cellular morphology imaging by confocal laser scanning microscopy (CLSM) and then identified by mass spectrometry (MS). Celastrol was successfully isolated as an Hsp 90 inhibitor, and two other specific components screened by Hsp 90α-MMFNPs, i.e., demecolcine and wilforine, were preliminarily identified as potential Hsp 90 inhibitors through the verification of strong affinity to Hsp 90 and antitumor bioactivity. The approach based on the MMFNPs provides a strong platform for imaging screening and discovery of plant-derived biologically active molecules with high efficiency and selectivity.

  20. Detecting Developmental Neurotoxicants Using Zebrafish Embryos

    EPA Science Inventory

    As part of EPA’s program on the screening and prioritization of chemicals for developmental neurotoxicity, a rapid, cost-effective in vivo vertebrate screen is being developed using an alternative species approach. Zebrafish (Danio rerio), a small freshwater fish with external f...

  1. A multiplex immunochromatographic test using gold nanoparticles for the rapid and simultaneous detection of four nitrofuran metabolites in fish samples.

    PubMed

    Wang, Quan; Liu, Yingchun; Wang, Mingyan; Chen, Yongjun; Jiang, Wei

    2018-01-01

    There is an urgent need for the rapid and simultaneous detection of multiple analytes present in a sample matrix. Here, a multiplex immunochromatographic test (multi-ICT) was developed that successfully allowed for the rapid and simultaneous detection of four major nitrofuran metabolites, i.e., 3-amino-2-oxazolidinone (AOZ), semicarbazide (SEM), 3-amino-5-methylmorpholino-2-oxazolidinone (AMOZ), and 1-aminohydantoin (AHD), in fish samples. Four different antigens were separately immobilized in four test lines on a nitrocellulose membrane. Goat anti-mouse immunoglobulin (IgG) was used as a control. Sensitive and specific monoclonal antibodies (mAbs) that recognize the corresponding antigens were selected for the assay, and no cross-reactivity between the antibodies in the detection assay was observed. The free analytes in samples or standards were pre-incubated with freeze-dried mAb-gold conjugates to improve the sensitivity of the detection assay. The multi-ICT detection was accomplished in less than 15 min by the naked eye. The cutoff values for the strip test were 0.5 ng/mL for AOZ and 0.75 ng/mL for AHD, SEM, and AMOZ, which were all below the maximum residue levels set by the European Union and China. A high degree of consistency was observed between the multi-ICT method and commercially available enzyme-linked immunosorbent assay (ELISA) kits using spiked, incurred, and "blind" fish samples, indicating the accuracy, reproducibility, and reliability of the novel test strip. This newly developed multi-ICT strip assay is suitable for the rapid and high-throughput screening of four nitrofuran metabolites in fish samples on-site, with no treatment or devices required. Graphical abstract A multiplex immunochromatographic test (multi-ICT) was developed that successfully allowed for the rapid and simultaneous detection of four major nitrofuran metabolites (AOZ, SEM, AMOZ, and AHD) in fish samples.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharma, R K; Freeman, III, R F

    Region III of the US Fish and Wildlife Service contracted with the Division of Environmental Impact Studies, Argonne National Laboratory, to make the 316(b) determination for the Donald C. Cook Nuclear Power Plant of the Indiana and Michigan Power Company and to make recommendations for improvement in intake design to facilitate compliance. To conduct this assessment, appropriate literature on screening systems and reports furnished by the applicant on intake design and operation and on ecological studies at the site were reviewed. Modifications of the location and design of the existing intake and possibilities of retrofitting with fine-mesh screening to screenmore » larval forms of fishes were examined. It was determined that currently there is no dictated need for fine-mesh screening of intake flow at the D.C. Cook Nuclear Power Plant.« less

  3. Bubble Point Measurements with Liquid Methane of a Screen Channel Capillary Liquid Acquisition Device

    NASA Technical Reports Server (NTRS)

    Jurns, John M.; McQuillen, John B.; Gaby, Joseph D., Jr.; Sinacore, Steven A., Jr.

    2009-01-01

    Liquid acquisition devices (LADs) can be utilized within a propellant tank in space to deliver single-phase liquid to the engine in low gravity. One type of liquid acquisition device is a screened gallery whereby a fine mesh screen acts as a 'bubble filter' and prevents the gas bubbles from passing through until a crucial pressure differential condition across the screen, called the bubble point, is reached. This paper presents data for LAD bubble point data in liquid methane (LCH4) for stainless steel Dutch twill screens with mesh sizes of 325 by 2300. These tests represent the first known nonproprietary effort to collect bubble point data for LCH4.

  4. Irradiate-anneal screening of total dose effects in semiconductor devices

    NASA Technical Reports Server (NTRS)

    Stanley, A. G.; Price, W. E.

    1976-01-01

    Judicious choice of radiation dose and parameter change acceptance criteria, absence of anomalous anneal phenomena, and absence of anomalous reirradiation effects are recognized as essential for a successful irradiation-anneal (IRAN) screening procedure to ensure that no device will fall, upon reirradiation, above parametric limits assigned for the worst case application. Reirradiation and irradiation-anneal behavior of various semiconductor devices are compared and those that do not lend themselves to IRAN screening are singled out. Information needed to judge the suitability of an IRAN type screening program is detailed. Reasons for success of the limited IRAN screening of flight parts for the Mariner Jupiter/Saturn (MJS '77) spacecraft are indicated.

  5. Microelectroporation device for genomic screening

    DOEpatents

    Perroud, Thomas D.; Renzi, Ronald F.; Negrete, Oscar; Claudnic, Mark R.

    2014-09-09

    We have developed an microelectroporation device that combines microarrays of oligonucleotides, microfluidic channels, and electroporation for cell transfection and high-throughput screening applications (e.g. RNA interference screens). Microarrays allow the deposition of thousands of different oligonucleotides in microscopic spots. Microfluidic channels and microwells enable efficient loading of cells into the device and prevent cross-contamination between different oligonucleotides spots. Electroporation allows optimal transfection of nucleic acids into cells (especially hard-to-transfect cells such as primary cells) by minimizing cell death while maximizing transfection efficiency. This invention has the advantage of a higher throughput and lower cost, while preventing cross-contamination compared to conventional screening technologies. Moreover, this device does not require bulky robotic liquid handling equipment and is inherently safer given that it is a closed system.

  6. Clinical significance of hTERC gene amplification detection by FISH in the screening of cervical lesions.

    PubMed

    Zhang, Yuan; Wang, Xiaobei; Ma, Ling; Wang, Zehua; Hu, Lihua

    2009-06-01

    This study evaluated the clinical significance of hTERC gene amplification detection by fluorescence in situ hybridization (FISH) in the screening of cervical lesions. Cervical specimens of 50 high risk patients were detected by thin liquid-based cytology. The patients whose cytological results were classified as ASCUS or above were subjected to the subsequent colposcopic biopsies. Slides prepared from these 50 cervical specimens were analyzed for hTERC gene amplification using interphase FISH with the two-color hTERC probe. The results of the cytological analysis and those of subsequent biopsies, when available, were compared with the FISH-detected hTERC abnormalities. It was found that the positive rates of hTERC gene amplification in NILM, ASCUS, LSIL, HSIL, and SCC groups were 0.00, 28.57%, 57.14%, 100%, and 100%, respectively. The positive rates of hTERC gene amplification in HSIL and SCC groups were significantly higher than those in NILM, ASCUS and LSIL groups (all P<0.05). The mean percentages of cells with hTERC gene amplification in NILM, ASCUS, LSIL, HSIL, and SCC groups were 0.00, 10.50%, 36.00%, 79.00%, and 96.50%, respectively. Patients with HSIL or SCC cytological diagnoses had significantly higher mean percentages of cells with hTERC gene amplification than did patients with NILM, ASCUS or LSIL cytological diagnoses (all P<0.05). It was concluded that two-color interphase FISH could detect hTERC gene amplification to accurately distinguish HSIL and ISIL of cervical cells. It may be an adjunct to cytology screening, especially high-risk patients.

  7. SCREENING AND TESTING FOR ENDOCRINE DISRUPTION IN FISH - BIOMARKERS AS "SIGNPOSTS," NOT "TRAFFIC LIGHTS," IN RISK ASSESSMENT

    EPA Science Inventory

    Biomarkers provide important tools for addressing the impacts of endocrine disrupting chemicals (EDCs) in fish. Presently, biomarkers are best used as mechanistic "signposts" rather than as "red traffic lights" in the environmental risk assessment of EDCs. In field studies, bio...

  8. Antibacterial activity of plant extracts from Brazil against fish pathogenic bacteria

    PubMed Central

    Castro, S.B.R.; Leal, C.A.G.; Freire, F.R.; Carvalho, D.A.; Oliveira, D.F.; Figueiredo, H.C.P.

    2008-01-01

    The aim of this work was to evaluate the antibacterial activity of Brazilian plants extracts against fish pathogenic bacteria. Forty six methanolic extracts were screened to identify their antibacterial properties against Streptococcus agalactiae, Flavobacterium columnare and Aeromonas hydrophila. Thirty one extracts showed antibacterial activity. PMID:24031303

  9. Alternatives to in vivo tests to detect endocrine disrupting chemicals (EDCs) in fish and amphibians – interactions with estrogens, androgens, and thyroid hormones

    EPA Science Inventory

    Endocrine disruption is considered a highly relevant endpoint for environmental risk assessment of chemicals, plant protection products, biocides and pharmaceuticals. Therefore, screening for endocrine disruption – with focus on vertebrates (fish and amphibians) and estrogen, and...

  10. Surveillance of Total Mercury and Methylmercury Concentrations in Retail Fish.

    PubMed

    Watanabe, Takahiro; Hayashi, Tomoko; Matsuda, Rieko; Akiyama, Hiroshi; Teshima, Reiko

    2017-01-01

    Most fish samples contain methylmercury, that the concentrations very greatly according to the fish species. To avoid the adverse health effects of methylmercury while retaining the benefits provided by fish consumption, it is important to select suitable fish species and to control the amount of the fish intake. We surveyed the concentrations of total mercury and methylmercury in 210 retail fish samples classified into 19 fish species by using validated analytical methods. The results of this survey were as follows. The total mercury and methylmercury concentrations were higher than 1 mg/kg in some samples of swordfish and bluefin tuna, which are large predatory fish species. In bluefin tuna and yellowtail, total mercury and methylmercury concentrations in farm-raised fish were lower than those in natural fish. There was a positive correlation between total mercury concentration and methylmercury concentration. Our results indicate that a cut-off value of 0.3 mg/kg total mercury in the screening of fish samples would increase the effectiveness of inspection.

  11. Statistical Survey of Persistent Organic Pollutants: Risk ...

    EPA Pesticide Factsheets

    U.S. EPA conducted a national statistical survey of fish tissue contamination at 540 river sites (representing 82 954 river km) in 2008–2009, and analyzed samples for 50 persistent organic pollutants (POPs), including 21 PCB congeners, 8 PBDE congeners, and 21 organochlorine pesticides. The survey results were used to provide national estimates of contamination for these POPs. PCBs were the most abundant, being measured in 93.5% of samples. Summed concentrations of the 21 PCB congeners had a national weighted mean of 32.7 μg/kg and a maximum concentration of 857 μg/kg, and exceeded the human health cancer screening value of 12 μg/kg in 48% of the national sampled population of river km, and in 70% of the urban sampled population. PBDEs (92.0%), chlordane (88.5%) and DDT (98.7%) were also detected frequently, although at lower concentrations. Results were examined by subpopulations of rivers, including urban or nonurban and three defined ecoregions. PCBs, PBDEs, and DDT occur at significantly higher concentrations in fish from urban rivers versus nonurban; however, the distribution varied more among the ecoregions. Wildlife screening values previously published for bird and mammalian species were converted from whole fish to fillet screening values, and used to estimate risk for wildlife through fish consumption. This work presents the results of the 2008-2009 National Rivers and Streams Assessment Survey (NRSA) where 50 persistent organic pollutants (POPs

  12. A PROTEOMIC (SELDI-TOF-MS) APPROACH TO ESTROGEN AGONIST SCREENING

    EPA Science Inventory

    A small fish model and surface enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI) were used to investigate plasma protein expression as a means to screen chemicals for estrogenic activity. Adult male sheepshead minnows (Cyprinodon variegatus) were place...

  13. Diving deeper into Zebrafish development of social behavior: analyzing high resolution data.

    PubMed

    Buske, Christine; Gerlai, Robert

    2014-08-30

    Vertebrate model organisms have been utilized in high throughput screening but only with substantial cost and human capital investment. The zebrafish is a vertebrate model species that is a promising and cost effective candidate for efficient high throughput screening. Larval zebrafish have already been successfully employed in this regard (Lessman, 2011), but adult zebrafish also show great promise. High throughput screening requires the use of a large number of subjects and collection of substantial amount of data. Collection of data is only one of the demanding aspects of screening. However, in most screening approaches that involve behavioral data the main bottleneck that slows throughput is the time consuming aspect of analysis of the collected data. Some automated analytical tools do exist, but often they only work for one subject at a time, eliminating the possibility of fully utilizing zebrafish as a screening tool. This is a particularly important limitation for such complex phenotypes as social behavior. Testing multiple fish at a time can reveal complex social interactions but it may also allow the identification of outliers from a group of mutagenized or pharmacologically treated fish. Here, we describe a novel method using a custom software tool developed within our laboratory, which enables tracking multiple fish, in combination with a sophisticated analytical approach for summarizing and analyzing high resolution behavioral data. This paper focuses on the latter, the analytic tool, which we have developed using the R programming language and environment for statistical computing. We argue that combining sophisticated data collection methods with appropriate analytical tools will propel zebrafish into the future of neurobehavioral genetic research. Copyright © 2014. Published by Elsevier B.V.

  14. A novel screen-printed microfluidic paper-based electrochemical device for detection of glucose and uric acid in urine.

    PubMed

    Yao, Yong; Zhang, Chunsun

    2016-10-01

    A novel screen-printed microfluidic paper-based analytical device with all-carbon electrode-enabled electrochemical assay (SP-ACE-EC-μPAD) has been developed. The fabrication of these devices involved wax screen-printing, which was simple, low-cost and energy-efficient. The working, counter and reference electrodes were screen-printed using carbon ink on the patterned paper devices. Different wax screen-printing processes were examined and optimized, which led to an improved method with a shorter heating time (~5 s) and a lower heating temperature (75 °C). Different printing screens were examined, with a 300-mesh polyester screen yielding the highest quality wax screen-prints. The carbon electrodes were screen-printed on the μPADs and then examined using cyclic voltammetry. The analytical performance of the SP-ACE-EC-μPADs for the detection of glucose and uric acid in standard solutions was investigated. The results were reproducible, with a linear relationship [R(2) = 0.9987 (glucose) or 0.9997 (uric acid)] within the concentration range of interest, and with detection limits as low as 0.35 mM (glucose) and 0.08 mM (uric acid). To determine the clinical utility of the μPADs, chronoamperometry was used to analyze glucose and uric acid in real urine samples using the standard addition method. Our devices were able to detect the analytes of interest in complex real-world biological samples, and have the potential for use in a wide variety of applications.

  15. Mobile input device type, texting style and screen size influence upper extremity and trapezius muscle activity, and cervical posture while texting.

    PubMed

    Kietrys, David M; Gerg, Michael J; Dropkin, Jonathan; Gold, Judith E

    2015-09-01

    This study aimed to determine the effects of input device type, texting style, and screen size on upper extremity and trapezius muscle activity and cervical posture during a short texting task in college students. Users of a physical keypad produced greater thumb, finger flexor, and wrist extensor muscle activity than when texting with a touch screen device of similar dimensions. Texting on either device produced greater wrist extensor muscle activity when texting with 1 hand/thumb compared with both hands/thumbs. As touch screen size increased, more participants held the device on their lap, and chose to use both thumbs less. There was also a trend for greater finger flexor, wrist extensor, and trapezius muscle activity as touch screen size increased, and for greater cervical flexion, although mean differences for cervical flexion were small. Future research can help inform whether the ergonomic stressors observed during texting are associated with musculoskeletal disorder risk. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  16. Fish oil supplementation and insulin sensitivity: a systematic review and meta-analysis.

    PubMed

    Gao, Huanqing; Geng, Tingting; Huang, Tao; Zhao, Qinghua

    2017-07-03

    Fish oil supplementation has been shown to be associated with a lower risk of metabolic syndrome and benefit a wide range of chronic diseases, such as cardiovascular disease, type 2 diabetes and several types of cancers. However, the evidence of fish oil supplementation on glucose metabolism and insulin sensitivity is still controversial. This meta-analysis summarized the exist evidence of the relationship between fish oil supplementation and insulin sensitivity and aimed to evaluate whether fish oil supplementation could improve insulin sensitivity. We searched the Cochrane Library, PubMed, Embase database for the relevant studies update to Dec 2016. Two researchers screened the literature independently by the selection and exclusion criteria. Studies were pooled using random effect models to estimate a pooled SMD and corresponding 95% CI. This meta-analysis was performed by Stata 13.1 software. A total of 17 studies with 672 participants were included in this meta-analysis study after screening from 498 published articles found after the initial search. In a pooled analysis, fish oil supplementation had no effects on insulin sensitivity compared with the placebo (SMD 0.17, 95%CI -0.15 to 0.48, p = 0.292). In subgroup analysis, fish oil supplementation could benefit insulin sensitivity among people who were experiencing at least one symptom of metabolic disorders (SMD 0.53, 95% CI 0.17 to 0.88, p < 0.001). Similarly, there were no significant differences between subgroups of methods of insulin sensitivity, doses of omega-3 polyunsaturated fatty acids (n-3 PUFA) of fish oil supplementation or duration of the intervention. The sensitivity analysis indicated that the results were robust. Short-term fish oil supplementation is associated with increasing the insulin sensitivity among those people with metabolic disorders.

  17. A sensitive and high throughput TaqMan-based reverse transcription quantitative polymerase chain reaction assay efficiently discriminates ALK rearrangement from overexpression for lung cancer FFPE specimens.

    PubMed

    Lung, Jrhau; Lin, Yu-Ching; Hung, Ming-Szu; Jiang, Yuan Yuan; Lee, Kuan-Der; Lin, Paul Yann; Tsai, Ying Huang

    2016-04-01

    ALK fusion gene is an oncogenic driver in lung cancer with low prevalence, which can be ameliorated by crizotinib. Currently, ALK fusion gene can be diagnosed by fluorescence in situ hybridization (FISH) and immunohistochemistry (IHC), but inconstistnt results between the two methods are encountered regularly. To make the ALK fusion gene screening more efficient and to provide a simple solution to clarify the discrepancy between FISH and IHC results, a sensitive TaqMan-based reverse transcription quantitative polymerase chain reaction (RT-qPCR) assay was established. The 3-plex TaqMan-based RT-qPCR assay was established and performed on 102 archived formalin-fixed, paraffin-embedded (FFPE) NSCLC samples to detect ALK rearrangement and overexpression. Break-apart FISH and automatic immunohistochemistry based ALK assays were performed side by side using tissue microarray. The RT-qPCR was performed successfully for 80 samples and 10 of them showed positive signals. Three out of the 10 qPCR positive cases were further confirmed by FISH and IHC test. Two others were IHC positive and FISH negative, and expressed full-length ALK transcript. The rest were neither FISH nor IHC positive and their ALK expression level was significantly lower than those FISH or IHC positive cases. Our RT-qPCR assay demonstrates that the capability and reliability of ALK detection is comparable to FISH and IHC, but it is more effective at discriminating ALK rearrangement from overexpression. The RT-qPCR assay easily clarifies the discrepancy between FISH and IHC, and can be incorporated into routine ALK screening for lung cancer. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Discovery and characterization of natural products that act as pheromones in fish.

    PubMed

    Li, Ke; Buchinger, Tyler J; Li, Weiming

    2018-06-20

    Covering: up to 2018 Fish use a diverse collection of molecules to communicate with conspecifics. Since Karlson and Lüscher termed these molecules 'pheromones', chemists and biologists have joined efforts to characterize their structures and functions. In particular, the understanding of insect pheromones developed at a rapid pace, set, in part, by the use of bioassay-guided fractionation and natural product chemistry. Research on vertebrate pheromones, however, has progressed more slowly. Initially, biologists characterized fish pheromones by screening commercially available compounds suspected to act as pheromones based upon their physiological function. Such biology-driven screening has proven a productive approach to studying pheromones in fish. However, the many functions of fish pheromones and diverse metabolites that fish release make predicting pheromone identity difficult and necessitate approaches led by chemistry. Indeed, the few cases in which pheromone identification was led by natural product chemistry indicated novel or otherwise unpredicted compounds act as pheromones. Here, we provide a brief review of the approaches to identifying pheromones, placing particular emphasis on the promise of using natural product chemistry together with assays of biological activity. Several case studies illustrate bioassay-guided fractionation as an approach to pheromone identification in fish and the unexpected diversity of pheromone structures discovered by natural product chemistry. With recent advances in natural product chemistry, bioassay-guided fractionation is likely to unveil an even broader collection of pheromone structures and enable research that spans across disciplines.

  19. Detection of novel and potentially actionable anaplastic lymphoma kinase (ALK) rearrangement in colorectal adenocarcinoma by immunohistochemistry screening

    PubMed Central

    Wang, Kai; Kim, Sun Young; Jang, Jiryeon; Kim, Seung Tae; Park, Joon Oh; Lim, Ho Yeong; Kang, Won Ki; Park, Young Suk; Lee, Jiyun; Lee, Woo Yong; Park, Yoon Ah; Huh, Jung Wook; Yun, Seong Hyeon; Do, In-Gu; Kim, Seok Hyung; Balasubramanian, Sohail; Stephens, Philip J.; Ross, Jeffrey S.; Li, Gang Gary; Hornby, Zachary; Ali, Siraj M.; Miller, Vincent A.; Kim, Kyoung-Mee; Ou, Sai-Hong Ignatius

    2015-01-01

    Purpose Anaplastic lymphoma kinase (ALK) rearrangement has been detected in colorectal carcinoma (CRC) using advanced molecular diagnostics tests including exon scanning, fluorescence in situ hybridization (FISH), and next generation sequencing (NGS). We investigated if immunohistochemistry (IHC) can be used to detect ALK rearrangement in gastrointestinal malignancies. Experimental designs Tissue microarrays (TMAs) from consecutive gastric carcinoma (GC) and CRC patients who underwent surgical resection at Samsung Medical Center, Seoul, Korea were screened by IHC using ALK monoclonal antibody 5A4. IHC positive cases were confirmed by FISH, nCounter assays, and NGS-based comprehensive genomic profiling (CGP). ALK IHC was further applied to CRC patients enrolled in a pathway-directed therapeutic trial. Results Four hundred thirty-two GC and 172 CRC cases were screened by IHC. No GC sample was ALK IHC positive. One CRC (0.6%) was ALK IHC positive (3+) that was confirmed by ALK FISH and a novel CAD-ALK (C35; A20) fusion variant that resulted from a paracentric inversion event inv(2)(p22–21p23) was identified by CGP. One out of 50 CRC patients enrolled in a pathway-directed therapeutic trial was ALK IHC positive (3+) confirmed by ALK FISH and found to harbor the EML4-ALK (E21, A20) fusion variant by CGP. Growth of a tumor cell line derived from this EML4-ALK CRC patient was inhibited by ALK inhibitors crizotinib and entrectinib. Conclusions ALK IHC is a viable screening strategy for identifying ALK rearrangement in CRC. ALK rearrangement is a potential actionable driver mutation in CRC based on survival inhibition of patient tumor-derived cell line by potent ALK inhibitors. PMID:26172300

  20. Bubble Point Measurements with Liquid Methane of a Screen Capillary Liquid Acquisition Device

    NASA Technical Reports Server (NTRS)

    Jurns, John M.; McQuillen, John B.

    2009-01-01

    Liquid acquisition devices (LADs) can be utilized within a propellant tank in space to deliver single-phase liquid to the engine in low gravity. One type of liquid acquisition device is a screened gallery whereby a fine mesh screen acts as a bubble filter and prevents the gas bubbles from passing through until a crucial pressure differential condition across the screen, called the bubble point, is reached. This paper presents data for LAD bubble point data in liquid methane (LCH4) for stainless steel Dutch twill screens with mesh sizes of 325 by 2300 and 200 by 1400 wires per inch. Data is presented for both saturated and sub-cooled LCH4, and is compared with predicted values.

  1. 21 CFR 866.2420 - Oxidase screening test for gonorrhea.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Oxidase screening test for gonorrhea. 866.2420 Section 866.2420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2420 Oxidase...

  2. 21 CFR 866.2420 - Oxidase screening test for gonorrhea.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Oxidase screening test for gonorrhea. 866.2420 Section 866.2420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2420 Oxidase...

  3. 21 CFR 866.2420 - Oxidase screening test for gonorrhea.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Oxidase screening test for gonorrhea. 866.2420 Section 866.2420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2420 Oxidase...

  4. 21 CFR 866.2420 - Oxidase screening test for gonorrhea.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Oxidase screening test for gonorrhea. 866.2420 Section 866.2420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2420 Oxidase...

  5. 21 CFR 866.2420 - Oxidase screening test for gonorrhea.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Oxidase screening test for gonorrhea. 866.2420 Section 866.2420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2420 Oxidase...

  6. Developing a Screening Model to Establish Human Risk from Glacial Meltwater Release of Legacy Organochlorine Pollutants at the Silvretta Glacier in the Swiss Alps

    NASA Astrophysics Data System (ADS)

    Miner, K. R.

    2017-12-01

    Organochlorine pollutants (OCPs) banned globally by the Stockholm Convention in 2004 are reemerging from melting glaciers in numerous alpine ecosystems. Despite the known OCP influx from glaciers, a study of human risk from uptake of pesticides in glacial meltwater has never been attempted. Our study qualifies human uptake routes and quantifies risk utilizing published meltwater data from the Silvretta Glacier in the Swiss Alps in combination with methodology established by the US Environmental Protection Agency (EPA). Relatively high concentrations of OCPs in Silvretta glacier meltwater reflect proximity to use near high density populations and provide the best estimate of a 95th percentile human risk scenario. This screening level model assesses direct PCB risk to humans through consumption of fish tissue and meltwater. Our model shows a risk for both cancer and non-cancer disease impacts to children with lifetime exposure to glacial meltwater and an average local fish consumption. For adults with an abbreviated 30 year exposure timeframe, the risk for non-cancer effects is negligible and cancer effects are only barely above screening level. Populations that consume higher quantities of local fish are at greater risk, with additional challenges borne by children. Further direct study into the individual level risk to Swiss residents from glacial meltwater pollution is deemed necessary by our screening study.

  7. High-throughput, image-based screening of pooled genetic variant libraries

    PubMed Central

    Emanuel, George; Moffitt, Jeffrey R.; Zhuang, Xiaowei

    2018-01-01

    Image-based, high-throughput screening of genetic perturbations will advance both biology and biotechnology. We report a high-throughput screening method that allows diverse genotypes and corresponding phenotypes to be imaged in numerous individual cells. We achieve genotyping by introducing barcoded genetic variants into cells and using massively multiplexed FISH to measure the barcodes. We demonstrated this method by screening mutants of the fluorescent protein YFAST, yielding brighter and more photostable YFAST variants. PMID:29083401

  8. Validation of the custo screen 400 ambulatory blood pressure-monitoring device according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Bramlage, Peter; Deutsch, Cornelia; Krüger, Ralf; Wolf, Andreas; Müller, Peter; Zwingers, Thomas; Beime, Beate; Mengden, Thomas

    2014-01-01

    The aim of the present study was to validate the custo screen 400 ambulatory blood pressure-monitoring (ABPM) device according to the 2010 International Protocol revision of the European Society of Hypertension (ESH-IP). The device can be used for ABPM for up to 72 hours. Systolic and diastolic blood pressure (SBP and DBP, respectively) were sequentially measured in 33 adult subjects (13 males and 20 females) and compared with a standard mercury sphygmomanometer (two observers). A total of 99 comparison pairs were obtained. The custo screen 400 met the requirements of parts 1 and 2 of the ESH-IP revision 2010. The mean difference between the device and reference sphygmomanometer readings was -0.5±4.5 mmHg for SBP and -0.1±3.3 mmHg for DBP. All but one measurement were within the absolute difference of 10 mmHg between the device and the observers for SBP and DBP. The number of absolute differences between the device and the observers within a range of 5 mmHg was 84 of 99 readings for SBP, and 93 of 99 readings for DBP. The custo screen 400 ABPM device met the requirements of the 2010 ESH-IP revision, and hence can be recommended for ABPM in adults. To our knowledge, the custo screen 400 is the first device to pass the revised ESH-IP 2010.

  9. Validation of the custo screen 400 ambulatory blood pressure-monitoring device according to the European Society of Hypertension International Protocol revision 2010

    PubMed Central

    Bramlage, Peter; Deutsch, Cornelia; Krüger, Ralf; Wolf, Andreas; Müller, Peter; Zwingers, Thomas; Beime, Beate; Mengden, Thomas

    2014-01-01

    Objective The aim of the present study was to validate the custo screen 400 ambulatory blood pressure-monitoring (ABPM) device according to the 2010 International Protocol revision of the European Society of Hypertension (ESH-IP). The device can be used for ABPM for up to 72 hours. Materials and methods Systolic and diastolic blood pressure (SBP and DBP, respectively) were sequentially measured in 33 adult subjects (13 males and 20 females) and compared with a standard mercury sphygmomanometer (two observers). A total of 99 comparison pairs were obtained. Results The custo screen 400 met the requirements of parts 1 and 2 of the ESH-IP revision 2010. The mean difference between the device and reference sphygmomanometer readings was −0.5±4.5 mmHg for SBP and −0.1±3.3 mmHg for DBP. All but one measurement were within the absolute difference of 10 mmHg between the device and the observers for SBP and DBP. The number of absolute differences between the device and the observers within a range of 5 mmHg was 84 of 99 readings for SBP, and 93 of 99 readings for DBP. Conclusion The custo screen 400 ABPM device met the requirements of the 2010 ESH-IP revision, and hence can be recommended for ABPM in adults. To our knowledge, the custo screen 400 is the first device to pass the revised ESH-IP 2010. PMID:24868162

  10. On determining specifications and selections of alternative technologies for airport checked-baggage security screening.

    PubMed

    Feng, Qianmei

    2007-10-01

    Federal law mandates that every checked bag at all commercial airports be screened by explosive detection systems (EDS), explosive trace detection systems (ETD), or alternative technologies. These technologies serve as critical components of airport security systems that strive to reduce security risks at both national and global levels. To improve the operational efficiency and airport security, emerging image-based technologies have been developed, such as dual-energy X-ray (DX), backscatter X-ray (BX), and multiview tomography (MVT). These technologies differ widely in purchasing cost, maintenance cost, operating cost, processing rate, and accuracy. Based on a mathematical framework that takes into account all these factors, this article investigates two critical issues for operating screening devices: setting specifications for continuous security responses by different technologies; and selecting technology or combination of technologies for efficient 100% baggage screening. For continuous security responses, specifications or thresholds are used for classifying threat items from nonthreat items. By investigating the setting of specifications on system security responses, this article assesses the risk and cost effectiveness of various technologies for both single-device and two-device systems. The findings provide the best selection of image-based technologies for both single-device and two-device systems. Our study suggests that two-device systems outperform single-device systems in terms of both cost effectiveness and accuracy. The model can be readily extended to evaluate risk and cost effectiveness of multiple-device systems for airport checked-baggage security screening.

  11. SEM/EDS and optical microscopy analyses of microplastics in ocean trawl and fish guts.

    PubMed

    Wang, Zhong-Min; Wagner, Jeff; Ghosal, Sutapa; Bedi, Gagandeep; Wall, Stephen

    2017-12-15

    Microplastic particles from Atlantic and Pacific Ocean trawls, lab-fed fish guts and ocean fish guts have been characterized using optical microscopy and SEM/EDS in terms of size, morphology, and chemistry. We assessed whether these measurements could serve as a rapid screening process for subsequent identification of the likely microplastic candidates by micro-spectroscopy. Optical microscopy enabled morphological classification of the types of particles or fibers present in the sample, as well as the quantification of particle size ranges and fiber lengths. SEM/EDS analysis was used to rule out non-plastic particles and screen the prepared samples for potential microplastic, based on their element signatures and surface characteristics. Chlorinated plastics such as polyvinyl chloride (PVC) could be easily identified with SEM/EDS due to their unique elemental signatures including chlorine, as could mineral species that are falsely identified as plastics by optical microscopy. Particle morphology determined by optical microscopy and SEM suggests the fish ingested particles contained both degradation fragments from larger plastic pieces and also manufactured microplastics. SEM images of microplastic particle surfaces revealed characteristic cracks consistent with environmental exposure, as well as pigment particles consistent with manufactured materials. Most of the microplastic surfaces in the fish guts and ocean trawls were covered with biofilms, radiolarians, and crustaceans. Many of the fish stomachs contained micro-shell pieces which visually resembled microplastics. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. QR Codes in Higher Ed: Fad or Functional Tool?

    ERIC Educational Resources Information Center

    Gradel, Kathleen; Edson, Alden J.

    2013-01-01

    As higher education grapples with addressing the 21st century needs of learners, technology is a pervasive concern. Waters (2012) painted a picture of three historical "screens," namely the television screen, the computer monitor, and today's mobile device screen. As mobile devices become increasingly commonplace in the workplace and on the…

  13. Development of mediator-type biosensor to wirelessly monitor whole cholesterol concentration in fish.

    PubMed

    Takase, Mai; Murata, Masataka; Hibi, Kyoko; Huifeng, Ren; Endo, Hideaki

    2014-04-01

    We developed a wireless monitoring system to monitor fish condition by tracking the change in whole cholesterol concentration. The whole cholesterol concentration of fish is a source of steroid hormones or indicator of immunity level, which makes its detection important for tracking physiological condition of fish. Wireless monitoring system comprises of mediator-type biosensor and wireless transmission device. Biosensor is implantable to fish body, and transmission device is so light, in that fish is allowed to swim freely during monitoring. Cholesterol esterase and oxidase were fixated on to the detection site of biosensor and used to detect the whole cholesterol concentration. However, cholesterol oxidase incorporates oxidation-reduction reaction of oxygen for detection, which concentration fluctuates easily due to change in environmental condition. Meanwhile, mediator-type biosensor enables monitoring of whole cholesterol concentration by using mediator to substitute that oxidation-reduction reaction of oxygen. Characteristic of fabricated mediator-type biosensor was tested. The sensor output current of mediator-type biosensor remained stable compared to output current of non-mediator-type biosensor under fluctuating oxygen concentration of 0-8 ppm, which implied that this sensor is less affected by change in dissolved oxygen concentration. That biosensor was then implanted into fish for wireless monitoring. As a result, approximately 48 h of real-time monitoring was successful.

  14. Quantifying Acoustic Uncertainty Due to Marine Mammals and Fish Near the Shelfbreak Front off Cape Hatteras

    DTIC Science & Technology

    2015-09-30

    an AUV mounted acoustic source, 2) moored multi-element SHRU acoustic receiver arrays, 3) a shipboard acoustic resonator, 4) fish-attraction...devices (FAD’s), 5) a three- AUV fish-field mapping effort (employing sidescan sonar plus optics) and 6) ScanFish, ADCP, and moored sensor oceanographic...The acoustic model has been further refined. To obtain a better estimate of source positions, the navigation data of the source AUV (Snoopy) was

  15. 15 CFR Appendix B to Subpart R of... - Minor Projects for Purposes of § 922.193(a)(2)(iii)

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...), the Michigan Department of Environmental Quality (Department) issues permits for projects that are of... values or interests, including navigation and water quality. (h) Fish or wildlife habitat structures..., water monitoring devices, water quality testing devices, survey devices, and core sampling devices, if...

  16. A novel framework for interpretation of data from the fish short-term reproduction assay (FSTRA) for the detection of endocrined-disrupting chemicals

    EPA Science Inventory

    The fish short term reproduction assay (FSTRA) is a key component of the USEPA endocrine disruptor screening program (EDSP). The FSTRA considers several mechanistic and apical responses in fathead minnows (Pimephales promelas) to determine whether an unknown chemical is likely to...

  17. A novel framework for interpretation of data from the fish short-term reproduction assay (FSTRA) for the detection of endocrine-disrupting chemicals

    EPA Science Inventory

    The fish short term reproduction assay (FSTRA) is a key component of the USEPA endocrine disruptor screening program (EDSP). The FSTRA considers several mechanistic and apical responses in fathead minnows (Pimephales promelas) to determine whether an unknown chemical is likely t...

  18. RELATIVE BINDING AFFINITY OF ENDOCRINE DISRUPTING CHEMICALS TO ESTROGEN RECEPTOR IN TWO SPECIES OF FRESHWATER FISH

    EPA Science Inventory

    The US EPA has been mandated to screen industrial chemicals and pesticides for potential endocrine activity. To evaluate the potential for chemicals to cause endocrine disruption in fish we have previously measured the affinity of a number of chemicals for the rainbow trout estr...

  19. Anesthetic effect of 4-styrylpyridine on lamprey and fish

    USGS Publications Warehouse

    Howell, John H.; Thomas, Paul M.

    1964-01-01

    The anestheticp roperty of 4-styrylpyridine (4-SP) on fish and lamprey was first noticed during chemical screening search of a selective toxicant for larval lamprey (Applegate, Howell, Hall, and Smith, 1957). To assess the possible value of the compound as an anesthetic, we later conducted the experiments reviewed in this report.

  20. Improving Science Communication with Responsive Web Design

    NASA Astrophysics Data System (ADS)

    Hilverda, M.

    2013-12-01

    Effective science communication requires clarity in both content and presentation. Content is increasingly being viewed via the Web across a broad range of devices, which can vary in screen size, resolution, and pixel density. Readers access the same content from desktop computers, tablets, smartphones, and wearable computing devices. Creating separate presentation formats optimized for each device is inefficient and unrealistic as new devices continually enter the marketplace. Responsive web design is an approach that puts content first within a presentation design that responds automatically to its environment. This allows for one platform to be maintained that can be used effectively for every screen. The layout adapts to screens of all sizes ensuring easy viewing of content for readers regardless of their device. Responsive design is accomplished primarily by the use of media queries within style sheets, which allows for changes to layout properties to be defined based on media types (i.e. screen, print) and resolution. Images and other types of multimedia can also be defined to scale automatically to fit different screen dimensions, although some media types require additional effort for proper implementation. Hardware changes, such as high pixel density screens, also present new challenges for effective presentation of content. High pixel density screens contain a greater number of pixels within a screen area increasing the pixels per inch (PPI) compared to standard screens. The result is increased clarity for text and vector media types, but often decreased clarity for standard resolution raster images. Media queries and other custom solutions can assist by specifying higher resolution images for high pixel density screens. Unfortunately, increasing image resolution results in significantly more data being transferred to the device. Web traffic on mobile devices such as smartphones and tablets is on a steady growth trajectory and many mobile devices around the world use low-bandwidth connections. Communicating science effectively includes efficient delivery of the information to the reader. To meet this criteria, responsive designs should also incorporate "mobile first" elements such as serving ideal image sizes (a low resolution cell phone does not need to receive a large desktop image) and a focus on fast, readable content delivery. The technical implementation of responsive web design is constantly changing as new web standards and approaches become available. However, fundamental design principles such as grid layouts, clear typography, and proper use of white space should be an important part of content delivery within any responsive design. This presentation will discuss current responsive design approaches for improving scientific communication across multiple devices, operating systems, and bandwidth capacities. The presentation will also include example responsive designs for scientific papers and websites. Implementing a responsive design approach with a focus on content and fundamental design principles is an important step to ensuring scientific information remains clear and accessible as screens and devices continue to evolve.

  1. Comparing polychlorinated biphenyl concentrations and patterns in the Saginaw River using sediment, caged fish, and semipermeable membrane devices

    USGS Publications Warehouse

    Echols, K.R.; Gale, R.W.; Schwartz, T.R.; Huckins, J.N.; Williams, L.L.; Meadows, J.C.; Morse, D.; Petty, J.D.; Orazio, C.E.; Tillitt, D.E.

    2000-01-01

    Three techniques of assessing bioavailable polychlorinated biphenyls (PCBs) in the Saginaw River, MI, were compared: sediments, caged fish, and semipermeable membrane devices (SPMDs). SPMDs and caged fish were placed in the river for 28 days at five sites where sediments were also sampled. The samples were analyzed for PCB congeners to determine concentrations and patterns. Total PCB concentrations ranged from 33 to 280 ng/g (dry weight) in sediments, 46 to 290 ng/g (wet weight) in caged fish, and 77 to 790 ng/g in SPMDs. Previously reported rates of PCB accumulation by SPMDs were used to estimate aqueous concentrations from the PCB concentrations detected in the SPMDs. Sediment-water partition coefficients were used to estimate aqueous PCB concentrations from sediment. Steady-state bioconcentration factors and depuration rate constants were used to estimate dissolved PCB concentrations from caged channel catfish. Relative PCB patterns from the SPMDs, caged fish, and sediment were compared using principal components analysis. SPMD and sediment samples provide complementary information. Sediments reflect long-term accumulation and weathering, while SPMDs integrate water concentrations only during the sampling period. Because of higher water solubilities of lower-chlorinated PCBs these predominate in the SPMDs as compared to in the fish and sediments. Contaminant profile differences between caged fish and SPMDs are likely due to metabolism and depuration of certain PCB congeners by fish.Three techniques of assessing bioavailable polychlorinated biphenyls (PCBs) in the Saginaw River, Ml, were compared: sediments, caged fish, and semipermeable membrane devices (SPMDs). SPMDs and caged fish were placed in the river for 28 days at five sites where sediments were also sampled. The samples were analyzed for PCB congeners to determine concentrations and patterns. Total PCB concentrations ranged from 33 to 280 ng/g (dry weight) in sediments, 46 to 290 ng/g (wet weight) in caged fish, and 77 to 790 ng/g in SPMDs. Previously reported rates of PCB accumulation by SPMDs were used to estimate aqueous concentrations from the PCB concentrations detected in the SPMDs. Sediment-water partition coefficients were used to estimate aqueous PCB concentrations from sediment. Steady-state bioconcentration factors and depuration rate constants were used to estimate dissolved PCB concentrations from caged channel catfish. Relative PCB patterns from the SPMDs, caged fish, and sediment were compared using principal components analysis. SPMD and sediment samples provide complementary information. Sediments reflect long-term accumulation and weathering, while SPMDs integrate water concentrations only during the sampling period. Because of higher water solubilities of lower-chlorinated PCBs these predominate in the SPMDs as compared to in the fish and sediments. Contaminant profile differences between caged fish and SPMDs are likely due to metabolism and depuration of certain PCB congeners by fish.At five sites in the Saginaw River, MI, PCB concentrations were determined in the summer of 1993 using three methods: sediment analysis, concentrations in caged fish, and concentrations in semipermeable membrane devices (SPMDs). On average, total PCB concentrations in the SPMDs were twice those found in caged fish, and the SPMD-to-fish concentration ratios of di-, tri-, tetra-, and pentaCB homologues were 10.0, 3.0, 2.5, and 1.4, respectively. Average concentrations in the sediments were approximately half those in the SPMDs, and the caged fish showed a greater preponderance of higher log octanol-water partition coefficient PCBs similar to the sediment pattern. On average, the water PCB concentrations estimated from sediment concentrations were five times higher than those calculated from SPMDs and three times higher than those estimated from caged fish. The total PCB concentrations in sediment, caged fish, and SPMDs ranged 33-280, 46-290, and 77-790 ng/g, respectiv

  2. A strategy for screening of α-glucosidase inhibitors from Morus alba root bark based on the ligand fishing combined with high-performance liquid chromatography mass spectrometer and molecular docking.

    PubMed

    Wang, Zhen; Li, Xiaoqing; Chen, Menghan; Liu, Feiyan; Han, Chao; Kong, Lingyi; Luo, Jianguang

    2018-04-01

    A new method based on ligand fishing combined with high-performance liquid chromatography quadrupole-time-of-flight mass spectrometer and molecular docking was established to screen α-glucosidase inhibitors from a traditional Chinese medicine Morus alba root bark. α-Glucosidase was immobilized on magnetic nanoparticles, used as a solid support to incubate with crude extract. After ligand fishing, the eluates were analyzed by high-performance liquid chromatography quadrupole-time-of-flight mass spectrometer, obtaining eleven ligands (1-4, 6-12) eventually. In order to discriminate the non-specific binders and discover powerful enzyme inhibitors, molecular docking was further performed and three of the eleven ligands were optimized to be excellent α-glucosidase inhibitors by the confirmation of isolation and bioassay of individual compounds. These three ligands, sanggenons G (6), O (7) and sanggenol G (12) exhibited striking inhibitory activities with extremely low IC 50 values. The results suggest that established method will be applied to a wide range of target protein to screen potential bioactive constituents from herbal medicines. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Miniaturized Embryo Array for Automated Trapping, Immobilization and Microperfusion of Zebrafish Embryos

    PubMed Central

    Akagi, Jin; Khoshmanesh, Khashayar; Evans, Barbara; Hall, Chris J.; Crosier, Kathryn E.; Cooper, Jonathan M.; Crosier, Philip S.; Wlodkowic, Donald

    2012-01-01

    Zebrafish (Danio rerio) has recently emerged as a powerful experimental model in drug discovery and environmental toxicology. Drug discovery screens performed on zebrafish embryos mirror with a high level of accuracy the tests usually performed on mammalian animal models, and fish embryo toxicity assay (FET) is one of the most promising alternative approaches to acute ecotoxicity testing with adult fish. Notwithstanding this, automated in-situ analysis of zebrafish embryos is still deeply in its infancy. This is mostly due to the inherent limitations of conventional techniques and the fact that metazoan organisms are not easily susceptible to laboratory automation. In this work, we describe the development of an innovative miniaturized chip-based device for the in-situ analysis of zebrafish embryos. We present evidence that automatic, hydrodynamic positioning, trapping and long-term immobilization of single embryos inside the microfluidic chips can be combined with time-lapse imaging to provide real-time developmental analysis. Our platform, fabricated using biocompatible polymer molding technology, enables rapid trapping of embryos in low shear stress zones, uniform drug microperfusion and high-resolution imaging without the need of manual embryo handling at various developmental stages. The device provides a highly controllable fluidic microenvironment and post-analysis eleuthero-embryo stage recovery. Throughout the incubation, the position of individual embryos is registered. Importantly, we also for first time show that microfluidic embryo array technology can be effectively used for the analysis of anti-angiogenic compounds using transgenic zebrafish line (fli1a:EGFP). The work provides a new rationale for rapid and automated manipulation and analysis of developing zebrafish embryos at a large scale. PMID:22606275

  4. Development of suspect and non-target screening methods for detection of organic contaminants in highway runoff and fish tissue with high-resolution time-of-flight mass spectrometry.

    PubMed

    Du, Bowen; Lofton, Jonathan M; Peter, Katherine T; Gipe, Alexander D; James, C Andrew; McIntyre, Jenifer K; Scholz, Nathaniel L; Baker, Joel E; Kolodziej, Edward P

    2017-09-20

    Untreated urban stormwater runoff contributes to poor water quality in receiving waters. The ability to identify toxicants and other bioactive molecules responsible for observed adverse effects in a complex mixture of contaminants is critical to effective protection of ecosystem and human health, yet this is a challenging analytical task. The objective of this study was to develop analytical methods using liquid chromatography coupled to high-resolution quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) to detect organic contaminants in highway runoff and in runoff-exposed fish (adult coho salmon, Oncorhynchus kisutch). Processing of paired water and tissue samples facilitated contaminant prioritization and aided investigation of chemical bioavailability and uptake processes. Simple, minimal processing effort solid phase extraction (SPE) and elution procedures were optimized for water samples, and selective pressurized liquid extraction (SPLE) procedures were optimized for fish tissues. Extraction methods were compared by detection of non-target features and target compounds (e.g., quantity and peak area), while minimizing matrix interferences. Suspect screening techniques utilized in-house and commercial databases to prioritize high-risk detections for subsequent MS/MS characterization and identification efforts. Presumptive annotations were also screened with an in-house linear regression (log K ow vs. retention time) to exclude isobaric compounds. Examples of confirmed identifications (via reference standard comparison) in highway runoff include ethoprophos, prometon, DEET, caffeine, cotinine, 4(or 5)-methyl-1H-methylbenzotriazole, and acetanilide. Acetanilide was also detected in runoff-exposed fish gill and liver samples. Further characterization of highway runoff and fish tissues (14 and 19 compounds, respectively with tentative identification by MS/MS data) suggests that many novel or poorly characterized organic contaminants exist in urban stormwater runoff and exposed biota.

  5. Thermal preference predicts animal personality in Nile tilapia Oreochromis niloticus.

    PubMed

    Cerqueira, Marco; Rey, Sonia; Silva, Tome; Featherstone, Zoe; Crumlish, Margaret; MacKenzie, Simon

    2016-09-01

    Environmental temperature gradients provide habitat structure in which fish orientate and individual thermal choice may reflect an essential integrated response to the environment. The use of subtle thermal gradients likely impacts upon specific physiological and behavioural processes reflected as a suite of traits described by animal personality. In this study, we examine the relationship between thermal choice, animal personality and the impact of infection upon this interaction. We predicted that thermal choice in Nile tilapia Oreochromis niloticus reflects distinct personality traits and that under a challenge individuals exhibit differential thermal distribution. Nile tilapia were screened following two different protocols: 1) a suite of individual behavioural tests to screen for personality and 2) thermal choice in a custom-built tank with a thermal gradient (TCH tank) ranging from 21 to 33 °C. A first set of fish were screened for behaviour and then thermal preference, and a second set were tested in the opposite fashion: thermal then behaviour. The final thermal distribution of the fish after 48 h was assessed reflecting final thermal preferendum. Additionally, fish were then challenged using a bacterial Streptococcus iniae model infection to assess the behavioural fever response of proactive and reactive fish. Results showed that individuals with preference for higher temperatures were also classified as proactive with behavioural tests and reactive contemporaries chose significantly lower water temperatures. All groups exhibited behavioural fever recovering personality-specific thermal preferences after 5 days. Our results show that thermal preference can be used as a proxy to assess personality traits in Nile tilapia and it is a central factor to understand the adaptive meaning of animal personality within a population. Importantly, response to infection by expressing behavioural fever overrides personality-related thermal choice. © 2016 The Authors. Journal of Animal Ecology © 2016 British Ecological Society.

  6. Effect of Vibration on Retention Characteristics of Screen Acquisition Systems

    NASA Technical Reports Server (NTRS)

    Tegart, J. R.; Park, A. C.

    1977-01-01

    An analytical and experimental investigation of the effect of vibration on the retention characteristics of screen acquisition systems was performed. The functioning of surface tension devices using fine-mesh screens requires that the pressure differential acting on the screen be less than its pressure retention capability. When exceeded, screen breakdown will occur and gas-free expulsion of propellant will no longer be possible. An analytical approach to predicting the effect of vibration was developed. This approach considers the transmission of the vibration to the screens of the device and the coupling of the liquid and the screen in establishing the screen response. A method of evaluating the transient response of the gas/liquid interface within the screen was also developed.

  7. A Review of the Use of Touch-Screen Mobile Devices by People with Developmental Disabilities

    ERIC Educational Resources Information Center

    Stephenson, Jennifer; Limbrick, Lisa

    2015-01-01

    This article presents a review of the research on the use of mobile touch-screen devices such as PDAs, iPod Touches, iPads and smart phones by people with developmental disabilities. Most of the research has been on very basic use of the devices as speech generating devices, as a means of providing video, pictorial and/or audio self-prompting and…

  8. Microfluidic cell chips for high-throughput drug screening

    PubMed Central

    Chi, Chun-Wei; Ahmed, AH Rezwanuddin; Dereli-Korkut, Zeynep; Wang, Sihong

    2016-01-01

    The current state of screening methods for drug discovery is still riddled with several inefficiencies. Although some widely used high-throughput screening platforms may enhance the drug screening process, their cost and oversimplification of cell–drug interactions pose a translational difficulty. Microfluidic cell-chips resolve many issues found in conventional HTS technology, providing benefits such as reduced sample quantity and integration of 3D cell culture physically more representative of the physiological/pathological microenvironment. In this review, we introduce the advantages of microfluidic devices in drug screening, and outline the critical factors which influence device design, highlighting recent innovations and advances in the field including a summary of commercialization efforts on microfluidic cell chips. Future perspectives of microfluidic cell devices are also provided based on considerations of present technological limitations and translational barriers. PMID:27071838

  9. Mothers' views of their preschool child's screen-viewing behaviour: a qualitative study.

    PubMed

    Bentley, Georgina F; Turner, Katrina M; Jago, Russell

    2016-08-04

    Research on screen-viewing in preschool children has predominantly focused on television viewing. The rapid development of mobile devices (e.g. tablets, smart phones and e-readers) and the increase in their use by preschool children means there is a need to understand how and why these devices are used by this age group. The aim of this study was to explore mothers' views of their preschool children's screen viewing behaviour (including mobile devices) and investigate how preschool children use different screen-viewing devices. One-to-one, semi-structured interviews with mothers of preschool children (aged between 2 and 4 years old). Mothers were recruited through preschools, nurseries, and mother and toddler groups located within four areas of varying socio-economic status within Bristol, UK. Data were analysed thematically using a framework approach. Twenty-six mothers were interviewed. Mobile devices were regularly used as a form of screen-viewing for most children but were used on an ad hoc basis rather than being a habitual activity. The reasons and influences of mobile device use described by mothers were similar to that of television viewing. However, the portability of mobile devices meant that they were often used outside of the home as a distraction tool. Their multi-functionality meant that they could be used as a portable television, or for purposeful learning through educational games and applications. Some mothers showed concerns over mobile device use by their child, whilst others felt it was an important and useful educational tool. Although the majority of mothers felt they needed to set rules and restrictions for mobile device use, many mothers felt that they are also a necessary and unavoidable part of life. Mothers in this study suggested that mobile device use by preschool children is common. More research is needed to determine the impact of mobile device use in preschool children, how much time preschool children spend using mobile devices and which activities their use may be replacing.

  10. CLOSED-LOOP STRIPPING ANALYSIS (CLSA) OF ...

    EPA Pesticide Factsheets

    Synthetic musk compounds have been found in surface water, fish tissues, and human breast milk. Current techniques for separating these compounds from fish tissues require tedious sample clean-upprocedures A simple method for the deterrnination of these compounds in fish tissues has been developed. Closed-loop stripping of saponified fish tissues in a I -L Wheaton purge-and-trap vessel is used to strip compounds with high vapor pressures such as synthetic musks from the matrix onto a solid sorbent (Abselut Nexus). This technique is useful for screening biological tissues that contain lipids for musk compounds. Analytes are desorbed from the sorbent trap sequentially with polar and nonpolar solvents, concentrated, and directly analyzed by high resolution gas chromatography coupled to a mass spectrometer operating in the selected ion monitoring mode. In this paper, we analyzed two homogenized samples of whole fish tissues with spiked synthetic musk compounds using closed-loop stripping analysis (CLSA) and pressurized liquid extraction (PLE). The analytes were not recovered quantitatively but the extraction yield was sufficiently reproducible for at least semi-quantitative purposes (screening). The method was less expensive to implement and required significantly less sample preparation than the PLE technique. The research focused on in the subtasks is the development and application of state-of the-art technologies to meet the needs of the public, Office of Water,

  11. Spatial patterns of methylmercury risks to common loons and piscivorous fish in Canada.

    PubMed

    Depew, David C; Burgess, Neil M; Campbell, Linda M

    2013-11-19

    Deposition of inorganic mercury (Hg) from the atmosphere remains the principle source of Hg contamination for most aquatic ecosystems. Inorganic Hg is readily converted to toxic methylmercury (MeHg) that bioaccumulates in aquatic food webs and may pose a risk to piscivorous fish and wildlife. We conducted a screening-level risk assessment to evaluate the extent of risk to top aquatic piscivores: the common loon (Gavia immer), walleye (Sander vitreus), and northern pike (Esox lucius). Risk quotients (RQs) were calculated on the basis of a dietary Hg exposure indicator (HgPREY) modeled from over 230,000 observations of fish Hg concentrations at over 1900 locations across Canada and dietary Hg exposure screening benchmarks derived specifically for this assessment. HgPREY exceeded benchmark thresholds related to impaired productivity and behavior in adult loons at 10% and 36% of sites, respectively, and exceeded benchmark thresholds for impaired reproduction and health in fishes at 82% and 73% of sites, respectively. The ecozones of southeastern Canada characterized by extensive forest cover, elevated Hg deposition, and poorly buffered soils had the greatest proportion of RQs > 1.0. Results of this assessment suggest that common loons and piscivorous fishes would likely benefit from reductions in Hg deposition, especially in southeastern Canada.

  12. Successive and discrete spaced conditioning in active avoidance learning in young and aged zebrafish.

    PubMed

    Yang, Peng; Kajiwara, Riki; Tonoki, Ayako; Itoh, Motoyuki

    2018-05-01

    We designed an automated device to study active avoidance learning abilities of zebrafish. Open source tools were used for the device control, statistical computing, and graphic outputs of data. Using the system, we developed active avoidance tests to examine the effects of trial spacing and aging on learning. Seven-month-old fish showed stronger avoidance behavior as measured by color preference index with discrete spaced training as compared to successive spaced training. Fifteen-month-old fish showed a similar trend, but with reduced cognitive abilities compared with 7-month-old fish. Further, in 7-month-old fish, an increase in learning ability during trials was observed with discrete, but not successive, spaced training. In contrast, 15-month-old fish did not show increase in learning ability during trials. Therefore, these data suggest that discrete spacing is more effective for learning than successive spacing, with the zebrafish active avoidance paradigm, and that the time course analysis of active avoidance using discrete spaced training is useful to detect age-related learning impairment. Copyright © 2017 Elsevier Ireland Ltd and Japan Neuroscience Society. All rights reserved.

  13. A sampler for capturing larval and juvenile Atlantic menhaden

    USGS Publications Warehouse

    Hedrick, J.D.; Hedrick, L.R.; Margraf, F.J.

    2005-01-01

    Interest in capturing larval and juvenile Atlantic menhaden Brevoortia tyrannus for use in laboratory studies required the design and construction of a sampling device that would allow us to make collections of live fish from open-water areas. Our device for capturing 1-2.5-in larval-juvenile fish was constructed of a stainless steel frame that supported a 9.84-ft-long (3-m-long)5 cone plankton net with a 3.28-ft-diameter (1-m-diameter) opening and a 0.04-in (1-mm) mesh size. Although the plankton net was similar to that used during typical larval fish collections, the cod end was constructed of Plexiglas and was nearly watertight; this prevented impingement and injury to larval fish and provided a calm-water environment. The cod end was designed for quick release from the plankton net, and the entire cod end could be submerged into a 75-gal onboard holding tank. This design and technique obviated the netting or emerging of fish from the water until they were returned to the laboratory. ?? Copyright by the American Fisheries Society 2005.

  14. Liquid Acquisition Device Design Sensitivity Study

    NASA Technical Reports Server (NTRS)

    VanDyke, M. K.; Hastings, L. J.

    2012-01-01

    In-space propulsion often necessitates the use of a capillary liquid acquisition device (LAD) to assure that gas-free liquid propellant is available to support engine restarts in microgravity. If a capillary screen-channel device is chosen, then the designer must determine the appropriate combination screen mesh and channel geometry. A screen mesh selection which results in the smallest LAD width when compared to any other screen candidate (for a constant length) is desirable; however, no best screen exists for all LAD design requirements. Flow rate, percent fill, and acceleration are the most influential drivers for determining screen widths. Increased flow rates and reduced percent fills increase the through-the-screen flow pressure losses, which drive the LAD to increased widths regardless of screen choice. Similarly, increased acceleration levels and corresponding liquid head pressures drive the screen mesh selection toward a higher bubble point (liquid retention capability). After ruling out some screens on the basis of acceleration requirements alone, candidates can be identified by examining screens with small flow-loss-to-bubble point ratios for a given condition (i.e., comparing screens at certain flow rates and fill levels). Within the same flow rate and fill level, the screen constants inertia resistance coefficient, void fraction, screen pore or opening diameter, and bubble point can become the driving forces in identifying the smaller flow-loss-to-bubble point ratios.

  15. Multiplex screening of persistent organic pollutants in fish using spectrally encoded microspheres

    USDA-ARS?s Scientific Manuscript database

    Persistent organic pollutants (POPs) are food contaminants of global public health concern and known to be carcinogenic and endocrine disruptors. Their monitoring is essential and an easy-to-use, rapid and affordable multi-analyte screening method with simplified sample preparation can be a valuable...

  16. Screening for ALK in non-small cell lung carcinomas: 5A4 and D5F3 antibodies perform equally well, but combined use with FISH is recommended.

    PubMed

    Savic, Spasenija; Diebold, Joachim; Zimmermann, Anne-Katrin; Jochum, Wolfram; Baschiera, Betty; Grieshaber, Susanne; Tornillo, Luigi; Bisig, Bettina; Kerr, Keith; Bubendorf, Lukas

    2015-08-01

    Immunohistochemistry (IHC) has become a promising method for pre-screening ALK-rearrangements in non-small cell lung carcinomas (NSCLC). Various ALK antibodies, detection systems and automated immunostainers are available. We therefore aimed to compare the performance of the monoclonal 5A4 (Novocastra, Leica) and D5F3 (Cell Signaling, Ventana) antibodies using two different immunostainers. Additionally we analyzed the accuracy of prospective ALK IHC-testing in routine diagnostics. Seventy-two NSCLC with available ALK FISH results and enriched for FISH-positive carcinomas were retrospectively analyzed. IHC was performed on BenchMarkXT (Ventana) using 5A4 and D5F3, respectively, and additionally with 5A4 on Bond-MAX (Leica). Data from our routine diagnostics on prospective ALK-testing with parallel IHC, using 5A4, and FISH were available from 303 NSCLC. All three IHC protocols showed congruent results. Only 1/25 FISH-positive NSCLC (4%) was false negative by IHC. For all three IHC protocols the sensitivity, specificity, positive (PPV) and negative predictive values (NPV) compared to FISH were 96%, 100%, 100% and 97.8%, respectively. In the prospective cohort 3/32 FISH-positive (9.4%) and 2/271 FISH-negative (0.7%) NSCLC were false negative and false positive by IHC, respectively. In routine diagnostics the sensitivity, specificity, PPV and NPV of IHC compared to FISH were 90.6%, 99.3%, 93.5% and 98.9%, respectively. 5A4 and D5F3 are equally well suited for detecting ALK-rearranged NSCLC. BenchMark and BOND-MAX immunostainers can be used for IHC with 5A4. True discrepancies between IHC and FISH results do exist and need to be addressed when implementing IHC in an ALK-testing algorithm. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  17. Comparison of keypads and touch-screen mobile phones/devices as potential risk for microbial contamination.

    PubMed

    Koroglu, Mehmet; Gunal, Selami; Yildiz, Fatma; Savas, Mehtap; Ozer, Ali; Altindis, Mustafa

    2015-12-30

    Touch-screen mobile phones/devices (TMPs/Ds) are increasingly used in hospitals. They may act as a mobile reservoir for microbial pathogens. The rates of microbial contamination of TMPs/Ds and keypad mobile phones (KMPs) with respect to different variables including use by healthcare workers (HCWs)/non-HCWs and the demographic characteristics of users were investigated. A total of 205 mobile phones/devices were screened for microbial contamination: 76 devices belonged to HCWs and 129 devices belonged to the non-HCW group. By rubbing swabs to front screen, back, keypad, and metallic surfaces of devices, 444 samples were collected. Of 205 mobile phones/devices, 143 (97.9%) of the TMPs/Ds and 58 (98.3%) of the KMPs were positive for microbial contamination, and there were no significant differences in contamination rates between these groups, although TMPs/Ds had significantly higher microbial load than KMPs (p <0.05). The significant difference in this analysis was attributable to the screen size of mobile phones ≥ 5". Microbial contamination rates increased significantly as phone size increased (p <0.05). Higher numbers of coagulase-negative Staphylococci (CNS) were isolated from KMPs than TMPs/Ds (p = 0.049). The incidence of Enterococcus spp. was higher on the KMPs of HCWs, and methicillin resistant CNS was higher from the TMPs/Ds of non-HCWs (p <0.05). Isolation of CNS, Streptococcus spp. and Escherichia coli was higher from the TMPs/Ds of HCWs (p <0.05). We found no significant difference between TMP/Ds and KMPs in terms of microbial contamination, but TMP/Ds harboured more colonies and total microbial counts increased with screen size.

  18. A novel framework for interpretation of data from the fish short-term reproduction assay (FSTRA) for the detection of endocrine-disrupting chemicals (poster)

    EPA Science Inventory

    The fish short term reproduction assay (FSTRA) is a key component of the USEPA endocrine disruptor screening program (EDSP). The FSTRA considers several mechanistic and apical responses in fathead minnows (Pimephales promelas) to determine whether an unknown chemical is likely to...

  19. Emergence of carp edema virus in cultured ornamental koi carp, Cyprinus carpio koi, in India.

    PubMed

    Swaminathan, T Raja; Kumar, Raj; Dharmaratnam, Arathi; Basheer, V S; Sood, Neeraj; Pradhan, P K; Sanil, N K; Vijayagopal, P; Jena, J K

    2016-12-01

    A disease outbreak was reported in adult koi, Cyprinus carpio koi, from a fish farm in Kerala, India, during June 2015. The clinical signs were observed only in recently introduced adult koi, and an existing population of fish did not show any clinical signs or mortality. Microscopic examination of wet mounts from the gills of affected koi revealed minor infestation of Dactylogyrus sp. in a few koi. In bacteriological studies, only opportunistic bacteria were isolated from the gills of affected fish. The histopathological examination of the affected fish revealed necrotic changes in gills and, importantly, virus particles were demonstrated in cytoplasm of gill epithelial cells in transmission electron microscopy. The tissue samples from affected koi were negative for common viruses reported from koi viz. cyprinid herpesvirus 3, spring viraemia of carp virus, koi ranavirus and red sea bream iridovirus in PCR screening. However, gill tissue from affected koi carp was positive for carp edema virus (CEV) in the first step of nested PCR, and sequencing of PCR amplicons confirmed infection with CEV. No cytopathic effect was observed in six fish cell lines following inoculation of filtered tissue homogenate prepared from gills of affected fish. In bioassay, the symptoms could be reproduced by inoculation of naive koi with filtrate from gill tissue homogenate of CEV-positive fish. Subsequently, screening of koi showing clinical signs similar to koi sleepy disease from different locations revealed that CEV infection was widespread. To our knowledge, this is the first report of infection with CEV in koi from India.

  20. Zebrafish (Danio rerio) as a screen for attenuation of Lancefield group C streptococci and a model for streptococcal pathogenesis.

    PubMed

    Borst, L B; Patterson, S K; Lanka, S; Suyemoto, M M; Maddox, C W

    2013-05-01

    Group C streptococci are highly contagious pyogenic bacteria responsible for respiratory tract, lymph node, urogenital tract, and wound infections. Wild-type strains of Streptococcus equi ssp equi (S. equi) and Streptococcus equi ssp zooepidemicus (S. zoo) as well as a commercially available modified live vaccine strain of S. equi were evaluated for virulence in zebrafish. Survival times, histologic lesions, and relative gene expression were compared among groups. Based on the intramuscular route of infection, significantly shorter survival times were observed in fish infected with wild-type strain when compared to modified live vaccine and S. zoo strains. Histologically, S. zoo-infected fish demonstrated a marked increase in inflammatory infiltrates (predominantly macrophages) at the site of infection, as well as increased cellularity in the spleen and renal interstitium. In contrast, minimal cellular immune response was observed in S. equi-injected fish with local tissue necrosis and edema predominating. Based on whole comparative genomic hybridization, increased transcription of positive acute-phase proteins, coagulation factors, and antimicrobial peptides were observed in S. equi-injected fish relative to S. zoo-injected fish, while mediators of cellular inflammation, including CXC chemokines and granulin, were upregulated in S. zoo-injected fish relative to S. equi-injected fish. In a screen of 11 clinical isolates, S. equi strains with a single nucleotide deletion in the upstream region of szp, a known virulence factor of streptococci, were found to be significantly attenuated in zebrafish. These collective findings underscore the value of the zebrafish as a model of streptococcal pathogenesis.

  1. Towards understanding addiction factors of mobile devices: An eye tracking study on effect of screen size.

    PubMed

    Wibirama, Sunu; Nugroho, Hanung A

    2017-07-01

    Mobile devices addiction has been an important research topic in cognitive science, mental health, and human-machine interaction. Previous works observed mobile device addiction by logging mobile devices activity. Although immersion has been linked as a significant predictor of video game addiction, investigation on addiction factors of mobile device with behavioral measurement has never been done before. In this research, we demonstrated the usage of eye tracking to observe effect of screen size on experience of immersion. We compared subjective judgment with eye movements analysis. Non-parametric analysis on immersion score shows that screen size affects experience of immersion (p<;0.05). Furthermore, our experimental results suggest that fixational eye movements may be used as an indicator for future investigation of mobile devices addiction. Our experimental results are also useful to develop a guideline as well as intervention strategy to deal with smartphone addiction.

  2. Evaluating the Potential for Marine and Hydrokinetic Devices to Act as Artificial Reefs or Fish Aggregating Devices. Based on Analysis of Surrogates in Tropical, Subtropical, and Temperate U.S. West Coast and Hawaiian Coastal Waters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kramer, Sharon H.; Hamilton, Christine D.; Spencer, Gregory C.

    Wave energy converters (WECs) and tidal energy converters (TECs) are only beginning to be deployed along the U.S. West Coast and in Hawai‘i, and a better understanding of their ecological effects on fish, particularly on special-status fish (e.g., threatened and endangered) is needed to facilitate project design and environmental permitting. The structures of WECs and TECs placed on to the seabed, such as anchors and foundations, may function as artificial reefs that attract reef-associated fishes, while the midwater and surface structures, such as mooring lines, buoys, and wave or tidal power devices, may function as fish aggregating devices (FADs), formingmore » the nuclei for groups of fishes. Little is known about the potential for WECs and TECs to function as artificial reefs and FADs in coastal waters of the U.S. West Coast and Hawai‘i. We evaluated these potential ecological interactions by reviewing relevant information about fish associations with surrogate structures, such as artificial reefs, natural reefs, kelps, floating debris, oil and gas platforms, marine debris, anchored FADs deployed to enhance fishing opportunities, net-cages used for mariculture, and piers and docks. Based on our review, we postulate that the structures of WECs and TECs placed on or near the seabed in coastal waters of the U.S. West Coast and Hawai‘i likely will function as small-scale artificial reefs and attract potentially high densities of reef-associated fishes (including special-status rockfish species [Sebastes spp.] along the mainland), and that the midwater and surface structures of WECs placed in the tropical waters of Hawai‘i likely will function as de facto FADs with species assemblages varying by distance from shore and deployment depth. Along the U.S. West Coast, frequent associations with midwater and surface structures may be less likely: juvenile, semipelagic, kelp-associated rockfishes may occur at midwater and surface structures of WECs in coastal waters of southern California to Washington, and occasional, seasonal, or transitory associations of coastal pelagic fishes such as jack mackerel (Trachurus symmetricus) may also occur at WECs in these waters. Importantly, our review indicated that negative effects of WEC structures on special-status fish species, such as increased predation of juvenile salmonids or rockfishes, are not likely. In addition, WECs installed in coastal California, especially in southern California waters, have the potential to attract high densities of reef-associated fishes and may even contribute to rockfish productivity, if fish respond to the WECs similarly to oil and gas platforms, which have some of the highest secondary production per unit area of seafloor of any marine habitat studied globally (Claisse et al. 2014). We encountered some information gaps, owing to the paucity or lack, in key locations, of comparable surrogate structures in which fish assemblages and ecological interactions were studied. TECs are most likely to be used in the Puget Sound area, but suitable surrogates are lacking there. However, in similarly cold-temperate waters of Europe and Maine, benthopelagic fish occurred around tidal turbines during lower tidal velocities, and this type of interaction may be expected by similar species at TECs in Puget Sound. To address information gaps in the near term, such as whether WECs would function as FADs in temperate waters, studies of navigation buoys using hydroacoustics are recommended.« less

  3. Vitellogenin synthesis in primary cultures of fish liver cells as endpoint for in vitro screening of the (anti)estrogenic activity of chemical substances.

    PubMed

    Navas, José M; Segner, Helmut

    2006-10-25

    Concern over possible adverse effects of endocrine-disrupting compounds on fish has caused the development of appropriate testing methods. In vitro screening assays may provide initial information on endocrine activities of a test compound and thereby may direct and optimize subsequent testing. Induction of vitellogenin (VTG) is used as a biomarker of exposure of fish to estrogen-active substances. Since VTG induction can be measured not only in vivo but also in fish hepatocytes in vitro, the use of VTG induction response in isolated fish liver cells has been suggested as in vitro screen for identifying estrogenic-active substances. The main advantages of the hepatocyte VTG assay are considered its ability to detect effects of estrogenic metabolites, since hepatocytes in vitro remain metabolically competent, and its ability to detect both estrogenic and anti-estrogenic effects. In this article, we critically review the current knowledge on the VTG response of cultured fish hepatocytes to (anti)estrogenic substances. In particular, we discuss the sensitivity, specificity, and variability of the VTG hepatocyte assay. In addition, we review the available data on culture factors influencing basal and induced VTG production, the response to natural and synthetic estrogens as well as to xenoestrogens, the detection of indirect estrogens, and the sources of assay variability. The VTG induction in cultured fish hepatocytes is clearly influenced by culture conditions (medium composition, temperature, etc.) and culture system (hepatocyte monolayers, aggregates, liver slices, etc.). The currently available database on estrogen-mediated VTG induction in cultured teleost hepatocytes is too small to support conclusive statements on whether there exist systematic differences of the VTG response between in vitro culture systems, VTG analytical methods or fish species. The VTG hepatocyte assay detects sensitively natural and synthetic estrogens, whereas the response to xenoestrogens appears to be more variable. The detection of weak estrogens can be critical due to the overshadow with cytotoxic concentrations. Moreover, the VTG hepatocyte assay is able to detect antiestrogens as well as indirect estrogens, i.e substances which require metabolic activation to induce an estrogenic response. Nevertheless, more chemicals need to be analysed to corroborate this statement. It will be necessary to establish standardized protocols to minimize assay variability, and to develop a set of pass-fail criteria as well as cut-offs for designating positive and negative responses.

  4. Community triage of otology patients using a store-and-forward telemedicine device: A feasibility study.

    PubMed

    Gupta, Nishi; Chawla, Neeraj; Gupta, Digant; Dhawan, Nidhi; Janaki, Vidya R

    2017-07-01

    Chronic otitis media is a major contributor to acquired hearing loss in developing countries. Developing countries such as India, with huge populations and poor health infrastructures, have always felt the shortage of trained specialists who can provide quality care to meet the enormous demand for treatment of this disease. This pilot study assessed the feasibility of empowering trained health workers equipped with ENTraview, a store-and-forward telemedicine device that integrates a camera- enabled smart phone with an otoscope. This device allows the screening of otology patients within the community. Three months of extensive training was provided to five community health workers on primary ear and hearing care, including training on the use of the ENTraview device. Community otology screenings were conducted to triage otology patients and provide them with specialized ENT care at a tertiary hospital. In the initial 6 months of the project, 45 screening camps were organized, which screened 3,000 patients free of cost. Of these 3,000 screened patients, 54% (1,619) were referred for ENT consultation and 215 patients reported. Nearly 50% (103) of the 215 reporting patients required surgical intervention, and 29 patients underwent surgery. Reaching out to the community by remote screening of ear diseases by trained technicians with a telemedicine device seems to be an effective and cost-effective way to triage patients with otologic pathologies.

  5. Pointing Device Performance in Steering Tasks.

    PubMed

    Senanayake, Ransalu; Goonetilleke, Ravindra S

    2016-06-01

    Use of touch-screen-based interactions is growing rapidly. Hence, knowing the maneuvering efficacy of touch screens relative to other pointing devices is of great importance in the context of graphical user interfaces. Movement time, accuracy, and user preferences of four pointing device settings were evaluated on a computer with 14 participants aged 20.1 ± 3.13 years. It was found that, depending on the difficulty of the task, the optimal settings differ for ballistic and visual control tasks. With a touch screen, resting the arm increased movement time for steering tasks. When both performance and comfort are considered, whether to use a mouse or a touch screen for person-computer interaction depends on the steering difficulty. Hence, a input device should be chosen based on the application, and should be optimized to match the graphical user interface. © The Author(s) 2016.

  6. Virtual Environment TBI Screen (VETS)

    DTIC Science & Technology

    2014-10-01

    balance challenges performed on a modified Wii Balance Board . Implementation of this device will enhance current approaches in TBI and mild TBI (i.e...TBI) screen (VETS) device in measuring standing balance . This system consists of software, a Wii balance board , and a large screen television that...Validate Wii ™ Balance Board relative to NeuroCom forceplate ! Running Wii Balance Board validation protocol. ! Milestone Achieved:

  7. Improvement of screening methods for silicon planar semiconductor devices

    NASA Technical Reports Server (NTRS)

    Berger, W. M.

    1972-01-01

    The results of the program for the development of a more sensitive method for selecting silicon planar semiconductor devices for long life applications are reported. The manufacturing technologies (MOS and Bipolar) are discussed along with the screening procedures developed as a result of the tests and evaluations, and the effectiveness of the MOS and Bilayer screening procedures are evaluated.

  8. Touch-screen technology usage in toddlers.

    PubMed

    Ahearne, Caroline; Dilworth, Sinead; Rollings, Rachel; Livingstone, Vicki; Murray, Deirdre

    2016-02-01

    To establish the prevalence and patterns of use of touch-screen technologies in the toddler population. Parental questionnaires were completed for children aged 12 months to 3 years examining access to touch-screen devices and ability to perform common forms of interaction with touch-screen technologies. The 82 questionnaires completed on typically developing children revealed 71% of toddlers had access to touch-screen devices for a median of 15 min (IQR: 9.375-26.25) per day. By parental report, 24 months was the median age of ability to swipe (IQR: 19.5-30.5), unlock (IQR: 20.5-31.5) and active looking for touch-screen features (IQR: 22-30.5), while 25 months (IQR: 21-31.25) was the median age of ability to identify and use specific touch-screen features. Overall, 32.8% of toddlers could perform all four skills. From 2 years of age toddlers have the ability to interact purposefully with touch-screen devices and demonstrate a variety of common skills required to utilise touch-screen technology. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  9. Augmented Fish Health Monitoring; Volume I of II, Completion Report.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michak, Patty

    1991-05-01

    The Bonneville Power Administration (BPA) initiated the Augmented Fish Health Monitoring project in 1986. This project was a five year interagency project involving fish rearing agencies in the Columbia Basin. Historically, all agencies involved with fish health in the Columbia Basin were conducting various levels of fish health monitoring, pathogen screening and collection. The goals of this project were; to identify, develop and implement a standardized level of fish health methodologies, develop a common data collection and reporting format in the area of artificial production, evaluate and monitor water quality, improve communications between agencies and provide annual evaluation of fishmore » health information for production of healthier smolts. This completion report will contain a project evaluation, review of the goals of the project, evaluation of the specific fish health analyses, an overview of highlights of the project and concluding remarks. 8 refs., 1 fig., 4 tabs.« less

  10. [Avoidance of injuries to migrating fish by hydropower and water intake plants].

    PubMed

    Adam, B

    2004-03-01

    Every year numerous downstream migrating fish are lethally injured by hydro power plants and inlet works. Especially the katadromous Eel (Anguilla anguilla) and anadromous species like Atlantic Salmon (Salmo salar), which have to migrate downstream into the ocean for closing their life cycle, are highly endangered. Due to their specific migratory behavioral pattern, size and morphology conventional protection techniques, like screens do not properly keep them out from getting into the power plant intakes. Despite of the relevance of this problem for ecology and fishing, there are no protection and downstream migration facilities in Europe available, which can efficiently avoid the damage of all species and sizes of downstream migrating fish. Nevertheless according to protect the fish populations it's necessary to use consequently fish protection and downstream migration facilities, i.e. mechanical barrieres or alternative techniques like early warning systems as a prerequisit for a fish-friendly operational management of hydro power plants.

  11. Optimise inlet condition and design parameters of a new sewer overflow screening device using numerical model.

    PubMed

    Aziz, M A; Imteaz, M A; Huda, Nazmul; Naser, J

    2014-01-01

    After heavy rainfall, sewer overflow spills to receiving water bodies cause serious concern for the environment, aesthetics and public health. To overcome these problems this study investigated a new self-cleansing sewer overflow screening device. The device has a sewer overflow chamber, a rectangular tank and a slotted ogee weir to capture the gross pollutants. To design an efficient screening device a numerical computational fluid dynamic (CFD) model was used. A plausibility check of the CFD model was done using a one-dimensional analytical model. Results showed that an inlet parallel to the weir ensured better self-cleansing than an inlet perpendicular to the weir. Perforations should be at the bottom of the weir to get increased velocity and shear stress to create a favourable self-cleaning effect of the screening device. Increasing inlet length from 0.3 to 1.5 m reduced wave reflection up to 10%, which increased flow uniformity downstream and improved self-cleansing effect. The orientation of the ogee weir with the rectangular tank was found most uniform with a 1:3 (horizontal:vertical) slope. These results will help to maximise functional efficiency of the new sewer overflow screening device. Otherwise it would be too expensive to alter after installation and at times difficult to customise accordingly to existing urban drainage systems.

  12. Anemonefish oxygenate their anemone hosts at night.

    PubMed

    Szczebak, Joseph T; Henry, Raymond P; Al-Horani, Fuad A; Chadwick, Nanette E

    2013-03-15

    Many stony coral-dwelling fishes exhibit adaptations to deal with hypoxia among the branches of their hosts; however, no information exists on the respiratory ecophysiology of obligate fish associates of non-coral organisms such as sea anemones and sponges. This study investigated metabolic and behavioral interactions between two-band anemonefish (Amphiprion bicinctus) and bulb-tentacle sea anemones (Entacmaea quadricolor) at night. We measured the net dark oxygen uptake ( , μmol O2 h(-1)) of fish-anemone pairs when partners were separate from each other, together as a unit, and together as a unit but separated by a mesh screen that prevented physical contact. We also measured the effects of water current on sea anemone and quantified the nocturnal behaviors of fish in the absence and presence of host anemones in order to discern the impacts of anemone presence on fish behavior. Net of united pairs was significantly higher than that of both separated pairs and united pairs that were separated by a mesh screen. Anemone increased with flow rate from 0.5 to 2.0 cm s(-1), after which remained constant up to a water flow rate of 8.0 cm s(-1). Furthermore, the percentage time and bout frequency of flow-modulating behaviors by fish increased significantly when anemones were present. We conclude that physical contact between anemonefish and sea anemones elevates the of at least one of the partners at night, and anemonefish behavior at night appears to oxygenate sea anemone hosts and to augment the metabolism of both partners.

  13. Proteomic Analysis of Cytoskeleton Proteins in Fish.

    PubMed

    Gotesman, Michael; Menanteau-Ledouble, Simon; El-Matbouli, Mansour

    2016-01-01

    In this chapter, we describe laboratory protocols for rearing fish and a simple and efficient method of extracting and identifying pathogen and host proteins that may be involved in entry and replication of commercially important fish viruses. We have used the common carp (Cyprinus carpio L.) and goldfish (Cyprinus auratus) as a model system for studies of proteins involved in viral entry and replication. The chapter describes detailed protocols for maintenance of carp, cell culture, antibody purification of proteins, and use of electrospray-ionization mass spectrometry analysis to screen and identify cytoskeleton and other proteins that may be involved in viral infection and propagation in fish.

  14. United States Adolescents' Television, Computer, Videogame, Smartphone, and Tablet Use: Associations with Sugary Drinks, Sleep, Physical Activity, and Obesity.

    PubMed

    Kenney, Erica L; Gortmaker, Steven L

    2017-03-01

    To quantify the relationships between youth use of television (TV) and other screen devices, including smartphones and tablets, and obesity risk factors. TV and other screen device use, including smartphones, tablets, computers, and/or videogames, was self-reported by a nationally representative, cross-sectional sample of 24 800 US high school students (2013-2015 Youth Risk Behavior Surveys). Students also reported on health behaviors including sugar-sweetened beverage (SSB) intake, physical activity, sleep, and weight and height. Sex-stratified logistic regression models, adjusting for the sampling design, estimated associations between TV and other screen device use and SSB intake, physical activity, sleep, and obesity. Approximately 20% of participants used other screen devices for ≥5 hours daily. Watching TV ≥5 hours daily was associated with daily SSB consumption (aOR = 2.72, 95% CI: 2.23, 3.32) and obesity (aOR = 1.78, 95% CI: 1.40, 2.27). Using other screen devices ≥5 hours daily was associated with daily SSB consumption (aOR = 1.98, 95% CI: 1.69, 2.32), inadequate physical activity (aOR = 1.94, 95% CI: 1.69, 2.25), and inadequate sleep (aOR = 1.79, 95% CI: 1.54, 2.08). Using smartphones, tablets, computers, and videogames is associated with several obesity risk factors. Although further study is needed, families should be encouraged to limit both TV viewing and newer screen devices. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Six-Degree-of-Freedom Sensor Fish Design and Instrumentation

    PubMed Central

    Deng, Zhiqun; Carlson, Thomas J.; Duncan, Joanne P.; Richmond, Marshall C.

    2007-01-01

    Fish passing through dams may be injured or killed despite advances in turbine design, project operations and other fish bypass systems. The six-degree-of-freedom (6DOF) Sensor Fish device is an autonomous sensor package that characterizes the physical conditions and physical stresses to which fish are exposed when they pass through complex hydraulic environments. It has been used to identify the locations and operations where conditions are severe enough to injure or kill fish. During the design process, a set of governing equations of motion for the Sensor Fish was derived and simulated to understand the design implications of instrument selection and placement within the body of the device. The Sensor Fish package includes three rotation sensors, three acceleration sensors, a pressure sensor, and a temperature sensor with a sampling frequency of 2,000 Hz. Its housing is constructed of clear polycarbonate plastic. It is 24.5 mm in diameter and 90 mm in length and weighs about 43 g, similar to the size and density of a yearling salmon smolt. The accuracy of the pressure sensor was determined to be within 0.2 psi. In laboratory acceptance tests, the relative errors of both the linear acceleration and angular velocity measurements were determined to be less than 5%. An exposure is defined as a significant event when the acceleration reaches predefined thresholds. Based on the different characteristic of acceleration and rotation velocities, the exposure event is categorized as either a collision between the Sensor Fish and a solid structure or shear caused by turbulence. Since its development in 2005, the 6DOF Sensor Fish has been deployed successfully at many major dams in the United States. PMID:28903301

  16. Situated Learning in the Mobile Age: Mobile Devices on a Field Trip to the Sea

    ERIC Educational Resources Information Center

    Pfeiffer, Vanessa D. I.; Gemballa, Sven; Jarodzka, Halszka; Scheiter, Katharina; Gerjets, Peter

    2009-01-01

    This study focuses on learning about fish biodiversity via mobile devices in a situated learning scenario. Mobile devices do not only facilitate relating the presented information to the real world in a direct way; they also allow the provision of dynamic representations on demand. This study asks whether mobile devices are suited to support…

  17. Seamless tiled display system

    NASA Technical Reports Server (NTRS)

    Dubin, Matthew B. (Inventor); Larson, Brent D. (Inventor); Kolosowsky, Aleksandra (Inventor)

    2006-01-01

    A modular and scalable seamless tiled display apparatus includes multiple display devices, a screen, and multiple lens assemblies. Each display device is subdivided into multiple sections, and each section is configured to display a sectional image. One of the lens assemblies is optically coupled to each of the sections of each of the display devices to project the sectional image displayed on that section onto the screen. The multiple lens assemblies are configured to merge the projected sectional images to form a single tiled image. The projected sectional images may be merged on the screen by magnifying and shifting the images in an appropriate manner. The magnification and shifting of these images eliminates any visual effect on the tiled display that may result from dead-band regions defined between each pair of adjacent sections on each display device, and due to gaps between multiple display devices.

  18. Recent trends in digital halftoning

    NASA Astrophysics Data System (ADS)

    Delabastita, Paul A.

    1997-02-01

    Screening is perhaps the oldest form of image processing. The word refers to the mechanical cross line screens that were used at the beginning of this century for the purpose of photomechanical reproduction. Later on, these mechanical screens were replaced by photographic contact screens that enabled significantly improved process control. In the early eighties, the optical screening on graphic arts scanners was replaced by a combination of laser optics and electronic screening. The algorithms, however, were still digital implementations of the original optical methods. The printing needs in the fast growing computer and software industry gave birth to a number of alternative printing technologies such as electrophotographic and inkjet printing. Originally these deices were only designed for printing text, but soon people started experimenting and using them for printing images. The relatively low spatial resolutions of these new devices however made complete review of 'the screening issue' necessary to achieve an acceptable image quality. In this paper a number of recent developments in screening technology are summarized. Special attention is given to the interaction that exists between a halftone screen and the printing devices on which they are rendered including the color mixing behavior. Improved screening techniques are presented that take advantage of modeling the physical behavior of the rendering device.

  19. Comparing four different ALK antibodies with manual immunohistochemistry (IHC) to screen for ALK-rearranged non-small cell lung cancer (NSCLC).

    PubMed

    Shen, Qin; Wang, Xuan; Yu, Bo; Shi, Shanshan; Liu, Biao; Wang, Yanfen; Xia, Qiuyuan; Rao, Qiu; Zhou, Xiaojun

    2015-12-01

    Anaplastic lymphoma kinase (ALK)-rearranged non-small cell lung cancer (NSCLC) screening is essential to its treatment such as crizotinib. Different assays have been developed to detect ALK rearrangements, such as fluorescence in situ hybridization (FISH), reverse transcriptase-PCR (RT-PCR), and immunohistochemistry (IHC). However, ALK detection has not been applied widely in all hospitals. Moreover, IHC has been proposed to be a pre-screening tool because of its wide application in clinics. Since the low expression of ALK protein, the sensitivity and specificity of ALK antibody are the keys to the success of IHC screening. Therefore, we compared different antibodies to find the best one for IHC detection. We evaluated ALK expression by four different ALK antibodies: clone D5F3 (Ventana), clone D5F3 (CST), clone 1A4/1H7 (OriGene Tech.), and clone 5A4 (Abcam) based on manual IHC in a cohort of 60 NSCLCs. The results were compared with those from automated IHC (clone D5F3, Ventana). All cases were evaluated independently by ALK FISH. 32 ALK-positive and 28 ALK-negative NSCLCs were identified by automated IHC (D5F3, Ventana) and FISH analysis. Based on conventional manual IHC, the sensitivity of four antibodies-D5F3 (Ventana), D5F3 (CST), 1A4/1H7 (OriGene Tech.), and 5A4 (Abcam)-was 93.8%, 84.4%, 93.8%, and 56.3%, respectively. Their specificities and positive predictive values were 100%. The percentage of strong-moderate staining was 65.6%, 62.5%, 68.8%, and 21.9%, respectively. Compared with automated IHC (D5F3, Ventana), each staining concordance was 96.7%, 91.7%, 96.7%, and 76.7%, respectively, and each presented staining heterogeneity (weak-moderate-strong intensity). These data indicated that manual IHC with a more reliable ALK antibody might provide an effective strategy for screening ALK gene rearrangements in all NSCLC patients, followed by confirmatory FISH analysis in IHC-positive cases. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. Evaluating projects for improving fish and wildlife habitat on National Forests.

    Treesearch

    Fred H. Everest; Daniel R. Talhelm

    1982-01-01

    Recent legislation (PL. 93-452; P.L. 94-588) has emphasized improvement of fish and wildlife habitat on lands of the National Forest System. A sequential procedure has been developed for screening potential projects to identify those producing the greatest fishery benefits. The procedure—which includes program planning, project planning, and intensive benefit/cost...

  1. 76 FR 14959 - Fall Creek Hydro, LLC; Notice of Application Tendered for Filing With the Commission and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-18

    ... facilities: (1) An intake structure located on the face of the Corps dam and installed directly above one of the existing intake structures; (2) two 8-foot-diameter by 110-foot-long steel penstocks that would..., among other things, Eicher fish screens, steel pipes, multi-level release ports, open channels, a fish...

  2. Young Children Learning from Touch Screens: Taking a Wider View

    PubMed Central

    Lovato, Silvia B.; Waxman, Sandra R.

    2016-01-01

    Touch screen devices such as smartphones and tablets are now ubiquitous in the lives of American children. These devices permit very young children to engage interactively in an intuitive fashion with actions as simple as touching, swiping and pinching. Yet, we know little about the role these devices play in very young children’s lives or their impact on early learning and development. Here we focus on two areas in which existing research sheds some light on these issues with children under 3 years of age. The first measures transfer of learning, or how well children use information learned from screens to reason about events off-screen, using object retrieval and word learning tasks. The second measures the impact of interactive screens on parent-child interactions and story comprehension during reading time. More research is required to clarify the pedagogical potential and pitfalls of touch screens for infants and very young children, especially research focused on capabilities unique to touch screens and on the social and cultural contexts in which young children use them. PMID:27486421

  3. Establishment of a biomimetic device based on tri-layer polymer actuators--propulsion fins.

    PubMed

    Alici, Gursel; Spinks, Geoffrey; Huynh, Nam N; Sarmadi, Laleh; Minato, Rick

    2007-06-01

    We propose to use bending type tri-layer polymer actuators as propulsion fins for a biomimetic device consisting of a rigid body, like a box fish having a carapace, and paired fins running through the rigid body, like a fish having pectoral fins. The fins or polymer bending actuators can be considered as individually controlled flexible membranes. Each fin is activated with sinusoidal inputs such that there is a phase lag between the movements of successive fins to create enough thrust force for propulsion. Eight fins with 0.125 aspect ratio have been used along both sides of the rigid body to move the device in the direction perpendicular to the longitudinal axis of the body. The designed device with the paired fins was successfully tested, moving in an organic solution consisting of solvent, propylene carbonate (PC), and electrolyte. The design procedure outlined in this study is offered as a guide to making functional devices based on polymer actuators and sensors.

  4. Cross-species assay validation using the AOP “deiodinase ...

    EPA Pesticide Factsheets

    High throughput screening assays able to detect chemical interactions with specific biological targets are increasingly being used to identify chemicals that could be hazardous to humans or wildlife. Most of these assays examine interaction with mammalian proteins. The present work demonstrates that mammalian-based assays designed to screen for interactions of chemicals with deiodinase, an enzyme important to thyroid hormone signaling provides results that are generally consistent with those obtained when a fish-specific deiodinase assay was employed. This gives confidence, that in most cases, a mammalian-based screening assay should detect chemicals that could act as thyroid disrupting chemicals (through this particular mode of action) in fish as well as mammals. Thus, this work helps support implementation of more efficient and cost effective approaches to chemical safety assessment.Abstract: The Adverse Outcome Pathway (AOP) concept is increasingly being recognized as a promising conceptual framework for describing toxicity pathways, which contains information that is sufficient to predict an adverse outcome of regulatory importance. Previously, we assessed the feasibility of developing an alternative, mechanistically informative testing strategy to replace the chronic Fish Early-Life Stage test (FELS, OECD TG 210), using an AOP-based approach. We developed an AOP encompassing deiodinase (DIO) inhibition resulting in decreased T3 concentrations leading to im

  5. Using a partial sum method and GPS tracking data to identify area restricted search by artisanal fishers at moored fish aggregating devices in the Commonwealth of Dominica.

    PubMed

    Alvard, Michael; Carlson, David; McGaffey, Ethan

    2015-01-01

    Foragers must often travel from a central place to exploit aggregations of prey. These patches can be identified behaviorally when a forager shifts from travel to area restricted search, identified by a decrease in speed and an increase in sinuosity of movement. Faster, more directed movement is associated with travel. Differentiating foraging behavior at patches from travel to patches is important for a variety of research questions and has now been made easier by the advent of small, GPS devices that can track forager movement with high resolution. In the summer and fall of 2012, movement data were collected from GPS devices placed on foraging trips originating in the artisanal fishing village of Desa Ikan (pseudonym), on the east coast of the Caribbean island nation of the Commonwealth Dominica. Moored FADs are human-made structures anchored to the ocean floor with fish attraction material on or near the surface designed to effectively create a resource patch. The ultimate goal of the research is to understand how property rights are emerging after the introduction of fish aggregating device (FAD) technology at the site in 1999. This paper reports on research to identify area-restricted search foraging behavior at FAD patches. For 22 foraging trips simultaneous behavioral observations were made to ground-truth the GPS movement data. Using a cumulative sum method, area restricted search was identified as negative deviations from the mean travel speed and the method was able to correctly identify FAD patches in every case.

  6. Using a Partial Sum Method and GPS Tracking Data to Identify Area Restricted Search by Artisanal Fishers at Moored Fish Aggregating Devices in the Commonwealth of Dominica

    PubMed Central

    Alvard, Michael; Carlson, David; McGaffey, Ethan

    2015-01-01

    Foragers must often travel from a central place to exploit aggregations of prey. These patches can be identified behaviorally when a forager shifts from travel to area restricted search, identified by a decrease in speed and an increase in sinuosity of movement. Faster, more directed movement is associated with travel. Differentiating foraging behavior at patches from travel to patches is important for a variety of research questions and has now been made easier by the advent of small, GPS devices that can track forager movement with high resolution. In the summer and fall of 2012, movement data were collected from GPS devices placed on foraging trips originating in the artisanal fishing village of Desa Ikan (pseudonym), on the east coast of the Caribbean island nation of the Commonwealth Dominica. Moored FADs are human-made structures anchored to the ocean floor with fish attraction material on or near the surface designed to effectively create a resource patch. The ultimate goal of the research is to understand how property rights are emerging after the introduction of fish aggregating device (FAD) technology at the site in 1999. This paper reports on research to identify area-restricted search foraging behavior at FAD patches. For 22 foraging trips simultaneous behavioral observations were made to ground-truth the GPS movement data. Using a cumulative sum method, area restricted search was identified as negative deviations from the mean travel speed and the method was able to correctly identify FAD patches in every case. PMID:25647288

  7. High Prevalence of Extended-Spectrum β-Lactamase-Producing Enterobacteriaceae in Wild Fish from the Mediterranean Sea in Algeria.

    PubMed

    Brahmi, Soumia; Touati, Abdelaziz; Dunyach-Remy, Catherine; Sotto, Albert; Pantel, Alix; Lavigne, Jean-Philippe

    2018-04-01

    We investigated the prevalence of extended-spectrum β-lactamase (ESBL)-producing Enterobacteriaceae among wild fish from the coast of Bejaia (Algeria) in the Mediterranean Sea. From March 2012 to August 2013, gut and gill samples of wild fish were screened for the presence of ESBL-producing Enterobacteriaceae. Strains were characterized with regard to antibiotic resistance, β-lactamase content, plasmid-mediated quinolone resistance, aminoglycoside resistance genes, and clonality (repetitive sequence-based polymerase chain reaction profiles and multilocus sequence typing). Virulence traits were performed for Escherichia coli and Klebsiella pneumoniae isolates. Of the 300 fish studied, 64 (21.3%) isolates were screened as positive for ESBL producing by the double-disc method. The isolates corresponded to E. coli, K. pneumoniae, Enterobacter cloacae, Morganella morganii, Citrobacter freundii, and Proteus vulgaris. A predominance of bla CTX-M gene was observed with a prevalence of 60.5% (n = 46). Furthermore, our study describes the association of important coresistance and virulence factors in E. coli and K. pneumoniae. Twelve of the ESBL producers carried genes of the qnr family and oqxAB gene and six carried the aac(6')-Ib-cr gene. Our results highlight for the first time the diffusion of multidrug-resistant Enterobacteriaceae isolates carrying resistance and virulence genes in fish from the Mediterranean Sea in Algeria.

  8. Performance of a RT-PCR Assay in Comparison to FISH and Immunohistochemistry for the Detection of ALK in Non-Small Cell Lung Cancer.

    PubMed

    Hout, David R; Schweitzer, Brock L; Lawrence, Kasey; Morris, Stephan W; Tucker, Tracy; Mazzola, Rosetta; Skelton, Rachel; McMahon, Frank; Handshoe, John; Lesperance, Mary; Karsan, Aly; Saltman, David L

    2017-08-01

    Patients with lung cancers harboring an activating anaplastic lymphoma kinase ( ALK ) rearrangement respond favorably to ALK inhibitor therapy. Fluorescence in situ hybridization (FISH) and immunohistochemistry (IHC) are validated and widely used screening tests for ALK rearrangements but both methods have limitations. The ALK RGQ RT-PCR Kit (RT-PCR) is a single tube quantitative real-time PCR assay for high throughput and automated interpretation of ALK expression. In this study, we performed a direct comparison of formalin-fixed paraffin-embedded (FFPE) lung cancer specimens using all three ALK detection methods. The RT-PCR test (diagnostic cut-off Δ C t of ≤8) was shown to be highly sensitive (100%) when compared to FISH and IHC. Sequencing of RNA detected full-length ALK transcripts or EML4-ALK and KIF5B-ALK fusion variants in discordant cases in which ALK expression was detected by the ALK RT-PCR test but negative by FISH and IHC. The overall specificity of the RT-PCR test for the detection of ALK in cases without full-length ALK expression was 94% in comparison to FISH and sequencing. These data support the ALK RT-PCR test as a highly efficient and reliable diagnostic screening approach to identify patients with non-small cell lung cancer whose tumors are driven by oncogenic ALK.

  9. Performance of a RT-PCR Assay in Comparison to FISH and Immunohistochemistry for the Detection of ALK in Non-Small Cell Lung Cancer

    PubMed Central

    Hout, David R.; Lawrence, Kasey; Morris, Stephan W.; Tucker, Tracy; Mazzola, Rosetta; Skelton, Rachel; McMahon, Frank; Handshoe, John; Lesperance, Mary; Karsan, Aly

    2017-01-01

    Patients with lung cancers harboring an activating anaplastic lymphoma kinase (ALK) rearrangement respond favorably to ALK inhibitor therapy. Fluorescence in situ hybridization (FISH) and immunohistochemistry (IHC) are validated and widely used screening tests for ALK rearrangements but both methods have limitations. The ALK RGQ RT-PCR Kit (RT-PCR) is a single tube quantitative real-time PCR assay for high throughput and automated interpretation of ALK expression. In this study, we performed a direct comparison of formalin-fixed paraffin-embedded (FFPE) lung cancer specimens using all three ALK detection methods. The RT-PCR test (diagnostic cut-off ΔCt of ≤8) was shown to be highly sensitive (100%) when compared to FISH and IHC. Sequencing of RNA detected full-length ALK transcripts or EML4-ALK and KIF5B-ALK fusion variants in discordant cases in which ALK expression was detected by the ALK RT-PCR test but negative by FISH and IHC. The overall specificity of the RT-PCR test for the detection of ALK in cases without full-length ALK expression was 94% in comparison to FISH and sequencing. These data support the ALK RT-PCR test as a highly efficient and reliable diagnostic screening approach to identify patients with non-small cell lung cancer whose tumors are driven by oncogenic ALK. PMID:28763012

  10. Angiotensin converting enzyme immobilized on magnetic beads as a tool for ligand fishing.

    PubMed

    de Almeida, Fernando G; Vanzolini, Kenia L; Cass, Quezia B

    2017-01-05

    Angiotensin converting enzyme (ACE) presents an important role in blood pressure regulation, since that converts angiotensin I to the vasoconstrictor angiotensin II. Some commercially available ACE inhibitors are captopril, lisinopril and enalapril; due to their side effects, naturally occurring inhibitors have been prospected. In order to endorse this research field we have developed a new tool for ACE ligand screening. To this end, ACE was extracted from bovine lung, purified and chemically immobilized in modified ferrite magnetic beads (ACE-MBs). The ACE-MBs have shown a Michaelian kinetic behavior towards hippuryl-histidyl-leucine. Moreover, as proof of concept, the ACE-MBs was inhibited by lisinopril with a half maximal inhibitory concentration (IC 50 ) of 10nM. At the fishing assay, ACE-MBs were able not only to fish out the reference inhibitor, but also one peptide from a pool of tryptic digested BSA. In conclusion, ACE-MBs emerge as new straightforward tool for ACE kinetics determination, inhibition and binder screening. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Supplement Analysis for the Watershed Management Program Final EIS (DOE EIS /SA-156) - Upper Salmon River Anadromous Fish Passage Improvement Projects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keller, Carl J.

    2004-07-13

    BPA proposes to fund IDFG to plan and complete construction of fish passage improvements and water conservation activities that are contained within IDFG’s Statement of Work (SOW) for the period 7/1/04 to 6/30/05. The funding request contained in their SOW is part of an ongoing IDFG effort to fund anadromous fish passage projects that fall outside the scope of the Mitchell Act. The proposed SOW activities fall within the following four categories: Phase I-Planning and Design (gather data, perform investigations, and exchange information; perform surveys and assessments to be compliant; survey project sites and perform engineering designs; perform contract andmore » project management); Phase II-Construction and Implementation (procure materials and supplies, prepare contracts and solicit bids, plant native seedlings, complete capital improvements); Phase III-Operation and Maintenance (maintain office operations); and Phase IV- Monitoring and Evaluation (monitor and evaluate post-project effects, reporting). The SOW culminates with proposed construction of 18 capital improvement projects (Table 1 attached). The types of capital improvements include: screening gravity water diversions; consolidating and/or eliminating ditches; evaluating and screening pump diversions; evaluating and implementing water conservation activities; constructing screens along migration routes and rearing areas for hatchery and wild salmon; improving upstream and downstream passage for anadromous fish; and maximize benefits to aquatic habitat. Because each of the proposed projects in the SOW is still in the planning stages, the specifics of each still need to be completed.« less

  12. Toward the integration of optical sensors in smartphone screens using femtosecond laser writing.

    PubMed

    Lapointe, Jerome; Parent, Francois; de Lima Filho, Elton Soares; Loranger, Sébastien; Kashyap, Raman

    2015-12-01

    We demonstrate a new type of sensor incorporated directly into Corning Gorilla glass, an ultraresistant glass widely used in the screen of popular devices such as smartphones, tablets, and smart watches. Although physical space is limited in portable devices, the screens have been so far neglected in regard to functionalization. Our proof-of-concept shows a new niche for photonics device development, in which the screen becomes an active component integrated into the device. The sensor itself is a near-surface waveguide, sensitive to refractive index changes, enabling the analysis of liquids directly on the screen of a smartphone, without the need for any add-ons, thus opening this part of the device to advanced functionalization. The primary function of the screen is unaffected, since the sensor and waveguide are effectively invisible to the naked eye. We fabricated a waveguide just below the glass surface, directly written without any surface preparation, in which the change in refractive index on the surface-air interface changes the light guidance, thus the transmission of light. This work reports on sensor fabrication, using a femtosecond pulsed laser, and the light-interaction model of the beam propagating at the surface is discussed and compared with experimental measurement for refractive indexes in the range 1.3-1.7. A new and improved model, including input and output reflections due to the effective mode index change, is also proposed and yields a better match with our experimental measurements and also with previous measurements reported in the literature.

  13. Reasons for non-attendance to cervical screening and preferences for HPV self-sampling in Dutch women.

    PubMed

    Bosgraaf, Remko P; Ketelaars, Pleun J W; Verhoef, Viola M J; Massuger, Leon F A G; Meijer, Chris J L M; Melchers, Willem J G; Bekkers, Ruud L M

    2014-07-01

    High attendance rates in cervical screening are essential for effective cancer prevention. Offering HPV self-sampling to non-responders increases participation rates. The objectives of this study were to determine why non-responders do not attend regular screening, and why they do or do not participate when offered a self-sampling device. A questionnaire study was conducted in the Netherlands from October 2011 to December 2012. A total of 35,477 non-responders were invited to participate in an HPV self-sampling study; 5347 women did opt out. Finally, 30,130 women received a questionnaire and self-sampling device. The analysis was based on 9484 returned questionnaires (31.5%) with a self-sample specimen, and 682 (2.3%) without. Among women who returned both, the main reason for non-attendance to cervical screening was that they forgot to schedule an appointment (3068; 32.3%). The most important reason to use the self-sampling device was the opportunity to take a sample in their own time-setting (4763; 50.2%). A total of 30.9% of the women who did not use the self-sampling device preferred after all to have a cervical smear taken instead. Organisational barriers are the main reason for non-attendance in regular cervical screening. Important reasons for non-responders to the regular screening to use a self-sampling device are convenience and self-control. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Field test of on-site drug detection devices

    DOT National Transportation Integrated Search

    2000-10-01

    This NHTSA-sponsored study reports the findings of a field evaluation of five on-site drug screening devices used by law enforcement to screen for illicit drugs among drivers suspected of driving under the influence (DUI) of alcohol or other drugs. I...

  15. ALK rearrangement in a large series of consecutive non-small cell lung cancers: comparison between a new immunohistochemical approach and fluorescence in situ hybridization for the screening of patients eligible for crizotinib treatment.

    PubMed

    Alì, Greta; Proietti, Agnese; Pelliccioni, Serena; Niccoli, Cristina; Lupi, Cristiana; Sensi, Elisa; Giannini, Riccardo; Borrelli, Nicla; Menghi, Maura; Chella, Antonio; Ribechini, Alessandro; Cappuzzo, Federico; Melfi, Franca; Lucchi, Marco; Mussi, Alfredo; Fontanini, Gabriella

    2014-11-01

    Echinoderm microtubule associated proteinlike 4-anaplastic lymphoma receptor tyrosine kinase (EML4-ALK) translocation has been described in a subset of patients with non-small cell lung cancer (NSCLC) and has been shown to have oncogenic activity. Fluorescence in situ hybridization (FISH) is used to detect ALK-positive NSCLC, but it is expensive, time-consuming, and difficult for routine application. To evaluate the potential role of immunohistochemistry (IHC) as a screening tool to identify candidate cases for FISH analysis and for ALK inhibitor therapy in NSCLC. We performed FISH and IHC for ALK and mutational analysis for epidermal growth factor receptor (EGFR) and KRAS in 523 NSCLC specimens. We conducted IHC analysis with the monoclonal antibody D5F3 (Ventana Medical Systems, Tucson, Arizona) and a highly sensitive detection system. We also performed a MassARRAY-based analysis (Sequenom, San Diego, California) in a small subset of 11 samples to detect EML4-ALK rearrangement. Of the 523 NSCLC specimens, 20 (3.8%) were positive for ALK rearrangement by FISH analysis. EGFR and KRAS mutations were identified in 70 (13.4%) and 124 (23.7%) of the 523 tumor samples, respectively. ALK rearrangement and EGFR and KRAS mutations were mutually exclusive. Of 523 tumor samples analyzed, 18 (3.4%) were ALK(+) by IHC, 18 samples (3.4%) had concordant IHC and FISH results, and 2 ALK(+) cases (0.3%) by FISH failed to show ALK protein expression. In the 2 discrepant cases, we did not detect any mass peaks for the EML4-ALK variants by MassARRAY. Our results show that IHC may be a useful technique for selecting NSCLC cases to undergo ALK FISH analysis.

  16. Effectiveness of FISK, an invasiveness screening tool for non-native freshwater fishes, to perform risk identification assessments in the Iberian Peninsula.

    PubMed

    Almeida, David; Ribeiro, Filipe; Leunda, Pedro M; Vilizzi, Lorenzo; Copp, Gordon H

    2013-08-01

    Risk assessments are crucial for identifying and mitigating impacts from biological invasions. The Fish Invasiveness Scoring Kit (FISK) is a risk identification (screening) tool for freshwater fishes consisting of two subject areas: biogeography/history and biology/ecology. According to the outcomes, species can be classified under particular risk categories. The aim of this study was to apply FISK to the Iberian Peninsula, a Mediterranean climate region highly important for freshwater fish conservation due to a high level of endemism. In total, 89 fish species were assessed by three independent assessors. Results from receiver operating characteristic analysis showed that FISK can discriminate reliably between noninvasive and invasive fishes for Iberia, with a threshold of 20.25, similar to those obtained in several regions around the world. Based on mean scores, no species was categorized as "low risk," 50 species as "medium risk," 17 as "moderately high risk," 11 as "high risk," and 11 as "very high risk." The highest scoring species was goldfish Carassius auratus. Mean certainty in response was above the category "mostly certain," ranging from tinfoil barb Barbonymus schwanenfeldii with the lowest certainty to eastern mosquitofish Gambusia holbrooki with the highest level. Pair-wise comparison showed significant differences between one assessor and the other two on mean certainty, with these two assessors showing a high coincidence rate for the species categorization. Overall, the results suggest that FISK is a useful and viable tool for assessing risks posed by non-native fish in the Iberian Peninsula and contributes to a "watch list" in this region. © 2013 Crown copyright This article is published with the permission of the Controller of HMSO and the Queen's Printer for Scotland.

  17. Variable Shadow Screens for Imaging Optical Devices

    NASA Technical Reports Server (NTRS)

    Lu, Ed; Chretien, Jean L.

    2004-01-01

    Variable shadow screens have been proposed for reducing the apparent brightnesses of very bright light sources relative to other sources within the fields of view of diverse imaging optical devices, including video and film cameras and optical devices for imaging directly into the human eye. In other words, variable shadow screens would increase the effective dynamic ranges of such devices. Traditionally, imaging sensors are protected against excessive brightness by use of dark filters and/or reduction of iris diameters. These traditional means do not increase dynamic range; they reduce the ability to view or image dimmer features of an image because they reduce the brightness of all parts of an image by the same factor. On the other hand, a variable shadow screen would darken only the excessively bright parts of an image. For example, dim objects in a field of view that included the setting Sun or bright headlights could be seen more readily in a picture taken through a variable shadow screen than in a picture of the same scene taken through a dark filter or a narrowed iris. The figure depicts one of many potential variations of the basic concept of the variable shadow screen. The shadow screen would be a normally transparent liquid-crystal matrix placed in front of a focal-plane array of photodetectors in a charge-coupled-device video camera. The shadow screen would be placed far enough from the focal plane so as not to disrupt the focal-plane image to an unacceptable degree, yet close enough so that the out-of-focus shadows cast by the screen would still be effective in darkening the brightest parts of the image. The image detected by the photodetector array itself would be used as feedback to drive the variable shadow screen: The video output of the camera would be processed by suitable analog and/or digital electronic circuitry to generate a negative partial version of the image to be impressed on the shadow screen. The parts of the shadow screen in front of those parts of the image with brightness below a specified threshold would be left transparent; the parts of the shadow screen in front of those parts of the image where the brightness exceeded the threshold would be darkened by an amount that would increase with the excess above the threshold.

  18. Effects of Aging and Domain Knowledge on Usability in Small Screen Devices for Diabetes Patients

    NASA Astrophysics Data System (ADS)

    Calero Valdez, André; Ziefle, Martina; Horstmann, Andreas; Herding, Daniel; Schroeder, Ulrik

    Technology acceptance has become a key concept for the successful rollout of technical devices. Though the concept is intensively studied for nearly 20 years now, still, many open questions remain. This especially applies to technology acceptance of older users, which are known to be very sensitive to suboptimal interfaces and show considerable reservations towards the usage of new technology. Mobile small screen technology increasingly penetrates health care and medical applications. This study investigates impacts of aging, technology expertise and domain knowledge on user interaction using the example of diabetes. For this purpose user effectiveness and efficiency have been measured on a simulated small screen device and related to user characteristics, showing that age and technology expertise have a big impact on usability of the device. Furthermore, impacts of user characteristics and success during the trial on acceptance of the device were surveyed and analyzed.

  19. Effects of input device and motion type on a cursor-positioning task.

    PubMed

    Yau, Yi-Jan; Hwang, Sheue-Ling; Chao, Chin-Jung

    2008-02-01

    Many studies have investigated the performance of using nonkey-board input devices under static situations, but few have considered the effects of motion type on manipulating these input devices. In this study comparison of 12 mens' performance using four input devices (three trackballs: currently used, trackman wheel, and erectly held trackballs, as well as a touch screen) under five motion types of static, heave, roll, pitch, and random movements was conducted. The input device and motion type significantly affected movement speed and accuracy, and their interaction significantly affected the movement speed. The touch screen was the fastest but the least accurate input device. The erectly held trackball was the slowest, whereas the error rate of the currently used trackball was the lowest. Impairments of the random motion on movement time and error rate were larger than those of other motion types. Considering objective and subjective evaluations, the trackman wheel and currently used trackball were more efficient in operation than the erectly held trackball and touch screen under the motion environments.

  20. Novel Electrosorption-Enhanced Solid-Phase Microextraction Device for Ultrafast In Vivo Sampling of Ionized Pharmaceuticals in Fish.

    PubMed

    Qiu, Junlang; Wang, Fuxin; Zhang, Tianlang; Chen, Le; Liu, Yuan; Zhu, Fang; Ouyang, Gangfeng

    2018-01-02

    Decreasing the tedious sample preparation duration is one of the most important concerns for the environmental analytical chemistry especially for in vivo experiments. However, due to the slow mass diffusion paths for most of the conventional methods, ultrafast in vivo sampling remains challenging. Herein, for the first time, we report an ultrafast in vivo solid-phase microextraction (SPME) device based on electrosorption enhancement and a novel custom-made CNT@PPY@pNE fiber for in vivo sampling of ionized acidic pharmaceuticals in fish. This sampling device exhibited an excellent robustness, reproducibility, matrix effect-resistant capacity, and quantitative ability. Importantly, the extraction kinetics of the targeted ionized pharmaceuticals were significantly accelerated using the device, which significantly improved the sensitivity of the SPME in vivo sampling method (limits of detection ranged from 0.12 ng·g -1 to 0.25 ng·g -1 ) and shorten the sampling time (only 1 min). The proposed approach was successfully applied to monitor the concentrations of ionized pharmaceuticals in living fish, which demonstrated that the device and fiber were suitable for ultrafast in vivo sampling and continuous monitoring. In addition, the bioconcentration factor (BCF) values of the pharmaceuticals were derived in tilapia (Oreochromis mossambicus) for the first time, based on the data of ultrafast in vivo sampling. Therefore, we developed and validated an effective and ultrafast SPME sampling device for in vivo sampling of ionized analytes in living organisms and this state-of-the-art method provides an alternative technique for future in vivo studies.

  1. Sensor Fish: an autonomous sensor package for characterizing complex flow fields and fish passage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deng, Zhiqun; Martinez, Jayson J.; Lu, Jun

    Fish passing through dams or other hydraulic structures may be injured or killed despite advances in turbine design, project operations, and other fish bypass systems. The Sensor Fish (SF) device is an autonomous sensor package that characterizes the physical conditions and stressors to which fish are exposed during passage through hydro facilities. It was designed to move passively as a neutrally buoyant object through severe hydraulic environments, while collecting high-resolution sensor data. Since its first generation1, the SF device has been successfully deployed in many fish passage studies and has evolved to be a major tool for characterizing fish passagemore » conditions during fish passage in the Columbia River Basin. To better accelerate hydropower development, the U.S. Department of Energy Water Power Program provided funding to develop a new generation (Gen 2 SF) to incorporate more capabilities and accommodate a wider range of users over a broader range of turbine designs and operating environments. The Gen 2 SF (Figure 1) is approximately the size and density of a yearling salmon smolt and is nearly neutrally buoyant. It contains three-dimensional (3D) rotation sensors, 3D linear acceleration sensors, a pressure sensor, a temperature sensor, a 3D orientation sensor, a radiofrequency (RF) transmitter, and a recovery module2. A low-power microcontroller collects data from the sensors and stores up to 5 min of data on internal flash memory at a sampling frequency of 2048 Hz. The recovery module makes the SF positively buoyant after a pre-programmed period of time, causing it to float to the surface for recovery.« less

  2. Oral vaccination of fish: Lessons from humans and veterinary species.

    PubMed

    Embregts, Carmen W E; Forlenza, Maria

    2016-11-01

    The limited number of oral vaccines currently approved for use in humans and veterinary species clearly illustrates that development of efficacious and safe oral vaccines has been a challenge not only for fish immunologists. The insufficient efficacy of oral vaccines is partly due to antigen breakdown in the harsh gastric environment, but also to the high tolerogenic gut environment and to inadequate vaccine design. In this review we discuss current approaches used to develop oral vaccines for mass vaccination of farmed fish species. Furthermore, using various examples from the human and veterinary vaccine development, we propose additional approaches to fish vaccine design also considering recent advances in fish mucosal immunology and novel molecular tools. Finally, we discuss the pros and cons of using the zebrafish as a pre-screening animal model to potentially speed up vaccine design and testing for aquaculture fish species. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. Alternatives to in vivo tests to detect endocrine disrupting chemicals (EDCs) in fish and amphibians--screening for estrogen, androgen and thyroid hormone disruption.

    PubMed

    Scholz, S; Renner, P; Belanger, S E; Busquet, F; Davi, R; Demeneix, B A; Denny, J S; Léonard, M; McMaster, M E; Villeneuve, D L; Embry, M R

    2013-01-01

    Endocrine disruption is considered a highly relevant hazard for environmental risk assessment of chemicals, plant protection products, biocides and pharmaceuticals. Therefore, screening tests with a focus on interference with estrogen, androgen, and thyroid hormone pathways in fish and amphibians have been developed. However, they use a large number of animals and short-term alternatives to animal tests would be advantageous. Therefore, the status of alternative assays for endocrine disruption in fish and frogs was assessed by a detailed literature analysis. The aim was to (i) determine the strengths and limitations of alternative assays and (ii) present conclusions regarding chemical specificity, sensitivity, and correlation with in vivo data. Data from 1995 to present were collected related to the detection/testing of estrogen-, androgen-, and thyroid-active chemicals in the following test systems: cell lines, primary cells, fish/frog embryos, yeast and cell-free systems. The review shows that the majority of alternative assays measure effects directly mediated by receptor binding or resulting from interference with hormone synthesis. Other mechanisms were rarely analysed. A database was established and used for a quantitative and comparative analysis. For example, a high correlation was observed between cell-free ligand binding and cell-based reporter cell assays, between fish and frog estrogenic data and between fish embryo tests and in vivo reproductive effects. It was concluded that there is a need for a more systematic study of the predictive capacity of alternative tests and ways to reduce inter- and intra-assay variability.

  4. A historical review of the key bacterial and viral pathogens of Scottish wild fish.

    PubMed

    Wallace, I S; McKay, P; Murray, A G

    2017-12-01

    Thousands of Scottish wild fish were screened for pathogens by Marine Scotland Science. A systematic review of published and unpublished data on six key pathogens (Renibacterium salmoninarum, Aeromonas salmonicida, IPNV, ISAV, SAV and VHSV) found in Scottish wild and farmed fish was undertaken. Despite many reported cases in farmed fish, there was a limited number of positive samples from Scottish wild fish, however, there was evidence for interactions between wild and farmed fish. A slightly elevated IPNV prevalence was reported in wild marine fish caught close to Atlantic salmon, Salmo salar L., farms that had undergone clinical IPN. Salmonid alphavirus was isolated from wild marine fish caught near Atlantic salmon farms with a SAV infection history. Isolations of VHSV were made from cleaner wrasse (Labridae) used on Scottish Atlantic salmon farms and VHSV was detected in local wild marine fish. However, these pathogens have been detected in wild marine fish caught remotely from aquaculture sites. These data suggest that despite the large number of samples taken, there is limited evidence for clinical disease in wild fish due to these pathogens (although BKD and furunculosis historically occurred) and they are likely to have had a minimal impact on Scottish wild fish. © 2017 Crown Copyright. Journal of Fish Diseases © 2017 John Wiley & Sons Ltd.

  5. Marine Organisms with Anti-Diabetes Properties

    PubMed Central

    Lauritano, Chiara; Ianora, Adrianna

    2016-01-01

    Diabetes is a chronic degenerative metabolic disease with high morbidity and mortality rates caused by its complications. In recent years, there has been a growing interest in looking for new bioactive compounds to treat this disease, including metabolites of marine origin. Several aquatic organisms have been screened to evaluate their possible anti-diabetes activities, such as bacteria, microalgae, macroalgae, seagrasses, sponges, corals, sea anemones, fish, salmon skin, a shark fusion protein as well as fish and shellfish wastes. Both in vitro and in vivo screenings have been used to test anti-hyperglycemic and anti-diabetic activities of marine organisms. This review summarizes recent discoveries in anti-diabetes properties of several marine organisms as well as marine wastes, existing patents and possible future research directions in this field. PMID:27916864

  6. Strategies for rare-event detection: an approach for automated fetal cell detection in maternal blood.

    PubMed Central

    Oosterwijk, J C; Knepflé, C F; Mesker, W E; Vrolijk, H; Sloos, W C; Pattenier, H; Ravkin, I; van Ommen, G J; Kanhai, H H; Tanke, H J

    1998-01-01

    This article explores the feasibility of the use of automated microscopy and image analysis to detect the presence of rare fetal nucleated red blood cells (NRBCs) circulating in maternal blood. The rationales for enrichment and for automated image analysis for "rare-event" detection are reviewed. We also describe the application of automated image analysis to 42 maternal blood samples, using a protocol consisting of one-step enrichment followed by immunocytochemical staining for fetal hemoglobin (HbF) and FISH for X- and Y-chromosomal sequences. Automated image analysis consisted of multimode microscopy and subsequent visual evaluation of image memories containing the selected objects. The FISH results were compared with the results of conventional karyotyping of the chorionic villi. By use of manual screening, 43% of the slides were found to be positive (>=1 NRBC), with a mean number of 11 NRBCs (range 1-40). By automated microscopy, 52% were positive, with on average 17 NRBCs (range 1-111). There was a good correlation between both manual and automated screening, but the NRBC yield from automated image analysis was found to be superior to that from manual screening (P=.0443), particularly when the NRBC count was >15. Seven (64%) of 11 XY fetuses were correctly diagnosed by FISH analysis of automatically detected cells, and all discrepancies were restricted to the lower cell-count range. We believe that automated microscopy and image analysis reduce the screening workload, are more sensitive than manual evaluation, and can be used to detect rare HbF-containing NRBCs in maternal blood. PMID:9837832

  7. To twist, roll, stroke or poke? A study of input devices for menu navigation in the cockpit.

    PubMed

    Stanton, Neville A; Harvey, Catherine; Plant, Katherine L; Bolton, Luke

    2013-01-01

    Modern interfaces within the aircraft cockpit integrate many flight management system (FMS) functions into a single system. The success of a user's interaction with an interface depends upon the optimisation between the input device, tasks and environment within which the system is used. In this study, four input devices were evaluated using a range of Human Factors methods, in order to assess aspects of usability including task interaction times, error rates, workload, subjective usability and physical discomfort. The performance of the four input devices was compared using a holistic approach and the findings showed that no single input device produced consistently high performance scores across all of the variables evaluated. The touch screen produced the highest number of 'best' scores; however, discomfort ratings for this device were high, suggesting that it is not an ideal solution as both physical and cognitive aspects of performance must be accounted for in design. This study evaluated four input devices for control of a screen-based flight management system. A holistic approach was used to evaluate both cognitive and physical performance. Performance varied across the dependent variables and between the devices; however, the touch screen produced the largest number of 'best' scores.

  8. 46 CFR 180.72 - Personal flotation devices carried in addition to life jackets.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Personal flotation devices carried in addition to life jackets. 180.72 Section 180.72 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL... emergencies. (b) Wearable marine buoyant devices that include “ski vests,” “boating vests,” and “fishing vests...

  9. 46 CFR 180.72 - Personal flotation devices carried in addition to life jackets.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Personal flotation devices carried in addition to life jackets. 180.72 Section 180.72 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL... emergencies. (b) Wearable marine buoyant devices that include “ski vests,” “boating vests,” and “fishing vests...

  10. Screen time by different devices in adolescents: association with physical inactivity domains and eating habits.

    PubMed

    Delfino, Leandro D; Dos Santos Silva, Diego A; Tebar, William R; Zanuto, Edner F; Codogno, Jamile S; Fernandes, Rômulo A; Christofaro, Diego G

    2018-03-01

    Sedentary behaviors in adolescents are associated with using screen devices, analyzed as the total daily time in television viewing, using the computer and video game. However, an independent and clustered analysis of devices allows greater understanding of associations with physical inactivity domains and eating habits in adolescents. Sample of adolescents aged 10-17 years (N.=1011) from public and private schools, randomly selected. The use of screen devices was measured by hours per week spent in each device: TV, computer, videogames and mobile phone/tablet. Physical inactivity domains (school, leisure and sports), eating habits (weekly food consumption frequency) and socioeconomic status were assessed by questionnaire. The prevalence of high use of mobile phone/tablet was 70% among adolescents, 63% showed high use of TV or computer and 24% reported high use of videogames. High use of videogames was greater among boys and high use of mobile phone/tablet was higher among girls. Significant associations of high use of TV (OR=1.43, 95% CI: 1.04-1.99), computer (OR=1.44, 95% CI: 1.03-2.02), videogames (OR=1.65, 95% CI: 1.13-2.69) and consumption of snacks were observed. High use of computer was associated with fried foods consumption (OR=1.32, 95% CI: 1.01-1.75) and physical inactivity (OR=1.41, 95% CI: 1.03-1.95). Mobile phone was associated with consumption of sweets (OR=1.33, 95% CI: 1.00-1.80). Cluster using screen devices showed associations with high consumption of snacks, fried foods and sweets, even after controlling for confounding variables. The high use of screen devices was associated with high consumption of snacks, fried foods, sweets and physical inactivity in adolescents.

  11. A high-throughput lab-on-a-chip interface for zebrafish embryo tests in drug discovery and ecotoxicology

    NASA Astrophysics Data System (ADS)

    Zhu, Feng; Akagi, Jin; Hall, Chris J.; Crosier, Kathryn E.; Crosier, Philip S.; Delaage, Pierre; Wlodkowic, Donald

    2013-12-01

    Drug discovery screenings performed on zebrafish embryos mirror with a high level of accuracy. The tests usually performed on mammalian animal models, and the fish embryo toxicity assay (FET) is one of the most promising alternative approaches to acute ecotoxicity testing with adult fish. Notwithstanding this, conventional methods utilising 96-well microtiter plates and manual dispensing of fish embryos are very time-consuming. They rely on laborious and iterative manual pipetting that is a main source of analytical errors and low throughput. In this work, we present development of a miniaturised and high-throughput Lab-on-a-Chip (LOC) platform for automation of FET assays. The 3D high-density LOC array was fabricated in poly-methyl methacrylate (PMMA) transparent thermoplastic using infrared laser micromachining while the off-chip interfaces were fabricated using additive manufacturing processes (FDM and SLA). The system's design facilitates rapid loading and immobilization of a large number of embryos in predefined clusters of traps during continuous microperfusion of drugs/toxins. It has been conceptually designed to seamlessly interface with both upright and inverted fluorescent imaging systems and also to directly interface with conventional microtiter plate readers that accept 96-well plates. We also present proof-of-concept interfacing with a high-speed imaging cytometer Plate RUNNER HD® capable of multispectral image acquisition with resolution of up to 8192 x 8192 pixels and depth of field of about 40 μm. Furthermore, we developed a miniaturized and self-contained analytical device interfaced with a miniaturized USB microscope. This system modification is capable of performing rapid imaging of multiple embryos at a low resolution for drug toxicity analysis.

  12. Study on the quality of FRP fishing vessel based on improved Fishbone Chart

    NASA Astrophysics Data System (ADS)

    Sui, J. H.; Yu, Y. F.; Du, Q. F.; Jiang, D. W.

    2018-01-01

    The construction quality of FRP fishing vessels influences their production, use and industry development. In order to explore the factors that affect the construction quality of FRP fishing vessels, key factors affecting the construction quality of FRP fishing vessels are determined based on the quality problems of FRP fishing vessels constructed. The improved Fishbone Chart is used to analyze the eight factors of “human, machine, material, process, environment, inspection, design and information”. Taking the factors that affect the construction quality of FRP fishing vessels as the central target, the eight influencing factors were condensed into five aspects and a composite Fishbone Chart is drawn. The Fishbone Chart is used as the basic model, the influencing factors are sorted, screened and discriminated, and the system model convenient for construction site management and control is established. Finally, the causes of poor construction of FRP fishing vessels are analyzed and discussed, and relevant suggestions are put forward.

  13. Finding NEMO (novel electromaterial muscle oscillator): a polypyrrole powered robotic fish with real-time wireless speed and directional control

    NASA Astrophysics Data System (ADS)

    McGovern, Scott; Alici, Gursel; Truong, Van-Tan; Spinks, Geoffrey

    2009-09-01

    This paper presents the development of an autonomously powered and controlled robotic fish that incorporates an active flexural joint tail fin, activated through conducting polymer actuators based on polypyrrole (PPy). The novel electromaterial muscle oscillator (NEMO) tail fin assembly on the fish could be controlled wirelessly in real time by varying the frequency and duty cycle of the voltage signal supplied to the PPy bending-type actuators. Directional control was achieved by altering the duty cycle of the voltage input to the NEMO tail fin, which shifted the axis of oscillation and enabled turning of the robotic fish. At low speeds, the robotic fish had a turning circle as small as 15 cm (or 1.1 body lengths) in radius. The highest speed of the fish robot was estimated to be approximately 33 mm s-1 (or 0.25 body lengths s-1) and was achieved with a flapping frequency of 0.6-0.8 Hz which also corresponded with the most hydrodynamically efficient mode for tail fin operation. This speed is approximately ten times faster than those for any previously reported artificial muscle based device that also offers real-time speed and directional control. This study contributes to previously published studies on bio-inspired functional devices, demonstrating that electroactive polymer actuators can be real alternatives to conventional means of actuation such as electric motors.

  14. Evaluation of ALK rearrangement in Chinese non-small cell lung cancer using FISH, immunohistochemistry, and real-time quantitative RT- PCR on paraffin-embedded tissues.

    PubMed

    Zhang, Yun-Gang; Jin, Mu-Lan; Li, Li; Zhao, Hong-Ying; Zeng, Xuan; Jiang, Lei; Wei, Ping; Diao, Xiao-Li; Li, Xue; Cao, Qing; Tian, Xin-Xia

    2013-01-01

    Patients with ALK gene rearrangements often manifest dramatic responses to crizotinib, an ALK inhibitor. Accurate identification of patients with ALK-positive non-small cell lung cancer (NSCLC) is essential for the clinical application of ALK-targeted therapy. However, assessing EML4-ALK rearrangement in NSCLC remains challenging in routine pathology practice. The aim of this study was to compare the diagnostic accuracy of FISH, immunohistochemistry (IHC), and real-time quantitative RT-PCR (QPCR) methodologies for detection of EML4-ALK rearrangement in NSCLC and to appraise immunohistochemistry as a pre-screening tool. In this study, a total of 473 paraffin-embedded NSCLC samples from surgical resections and biopsies were analyzed by IHC with ALK antibody. ALK rearrangement was further confirmed by FISH and QPCR. ALK protein expression was detected in twenty patients (20/473, 4.2%). Of the 20 ALK-positive cases by IHC, 15 cases were further confirmed as ALK rearrangement by FISH, and 5 cases were not interpretable. Also, we evaluated 13 out of the 20 IHC-positive tissues by QPCR in additional to FISH, and found that 9 cases were positive and 2 cases were equivocal, whereas 2 cases were negative although they were positive by both IHC and FISH. The ALK status was concordant in 5 out of 8 cases that were interpretable by three methods. Additionally, none of the 110 IHC-negative cases with adenocarcinoma histology showed ALK rearrangements by FISH. Histologically, almost all the ALK-rearranged cases were adenocarcinoma, except that one case was sarcomatoid carcinoma. A solid signet-ring cell pattern or mucinous cribriform pattern was presented at least focally in all ALK-positive tumors. In conclusion, our findings suggested that ALK rearrangement was associated with ALK protein expression. The conventional IHC assay is a valuable tool for the pre-screening of patients with ALK rearrangement in clinical practice and a combination of FISH and QPCR is required for further confirmation.

  15. Three-dimensional hologram display system

    NASA Technical Reports Server (NTRS)

    Mintz, Frederick (Inventor); Chao, Tien-Hsin (Inventor); Bryant, Nevin (Inventor); Tsou, Peter (Inventor)

    2009-01-01

    The present invention relates to a three-dimensional (3D) hologram display system. The 3D hologram display system includes a projector device for projecting an image upon a display medium to form a 3D hologram. The 3D hologram is formed such that a viewer can view the holographic image from multiple angles up to 360 degrees. Multiple display media are described, namely a spinning diffusive screen, a circular diffuser screen, and an aerogel. The spinning diffusive screen utilizes spatial light modulators to control the image such that the 3D image is displayed on the rotating screen in a time-multiplexing manner. The circular diffuser screen includes multiple, simultaneously-operated projectors to project the image onto the circular diffuser screen from a plurality of locations, thereby forming the 3D image. The aerogel can use the projection device described as applicable to either the spinning diffusive screen or the circular diffuser screen.

  16. Internal Consistency Reliability of the Self-Report Antisocial Process Screening Device

    ERIC Educational Resources Information Center

    Poythress, Norman G.; Douglas, Kevin S.; Falkenbach, Diana; Cruise, Keith; Lee, Zina; Murrie, Daniel C.; Vitacco, Michael

    2006-01-01

    The self-report version of the Antisocial Process Screening Device (APSD) has become a popular measure for assessing psychopathic features in justice-involved adolescents. However, the internal consistency reliability of its component scales (Narcissism, Callous-Unemotional, and Impulsivity) has been questioned in several studies. This study…

  17. 36 CFR 13.1 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... shall apply to all regulations contained in this part: Aircraft means a machine or device that is used... means to wear, bear or carry on or about the person and additionally, in the case of firearms, within or... Preserve. Net means a seine, weir, net wire, fish trap, or other implement designed to entrap fish, except...

  18. 76 FR 38370 - Western Pacific Fisheries; Approval of a Marine Conservation Plan for Pacific Insular Areas...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-30

    ... seine vessels fishing on fish aggregation devices in the PRIA. b. Support tagging studies in the PRIA to... characteristics of federally managed species through bio-sampling. Objective 2. Conduct education and outreach to...-making process by supporting education and outreach activities related to sustainable fisheries...

  19. Hand-portable gas chromatography-ion mobility spectrometer for the determination of the freshness of fish

    NASA Technical Reports Server (NTRS)

    Snyder, A. Peter; Harden, Charles S.; Davis, Dennis M.; Shoff, Donald B.; Maswadeh, Waleed M.

    1995-01-01

    A hand-held, portable gas chromatography-ion mobility spectrometer (GC-IMS) device was used to detect the presence of volatile amine compounds in the headspace of decomposing fish. The Food and Drug Administration (FDA) largely relies on olfactory discrimination with respect to fresh and spoiled, frozen and unfrozen fish. The fish are delivered at ship docks on pallets, and each pallet of fish can range from 30-40 thousand dollars in value. Fresh fish were placed in a teflon bag and the direct headspace was interrogated. In the first three days, only low molecular weight volatile amines were detected. On the fourth day, a number of spectral signatures were observed which indicated the presence of 1,5-diaminopentane, cadaverine. Analyses typically took from 0.5-1 minute.

  20. Experimental methods in aquatic respirometry: the importance of mixing devices and accounting for background respiration.

    PubMed

    Rodgers, G G; Tenzing, P; Clark, T D

    2016-01-01

    In light of an increasing trend in fish biology towards using static respirometry techniques without the inclusion of a mixing mechanism and without accurately accounting for the influence of microbial (background) respiration, this paper quantifies the effect of these approaches on the oxygen consumption rates (ṀO2 ) measured from juvenile barramundi Lates calcarifer (mean ± s.e. mass = 20·31 ± 0·81 g) and adult spiny chromis damselfish Acanthochromis polyacanthus (22·03 ± 2·53 g). Background respiration changed consistently and in a sigmoidal manner over time in the treatment with a mixing device (inline recirculation pump), whereas attempts to measure background respiration in the non-mixed treatment yielded highly variable estimates of ṀO2 that were probably artefacts due to the lack of water movement over the oxygen sensor during measurement periods. This had clear consequences when accounting for background respiration in the calculations of fish ṀO2 . Exclusion of a mixing device caused a significantly lower estimate of ṀO2 in both species and reduced the capacity to detect differences between individuals as well as differences within an individual over time. There was evidence to suggest that the magnitude of these effects was dependent on the spontaneous activity levels of the fish, as the difference between mixed and non-mixed treatments was more pronounced for L. calcarifer (sedentary) than for A. polyacanthus (more spontaneously active). It is clear that respirometry set-ups for sedentary species must contain a mixing device to prevent oxygen stratification inside the respirometer. While more active species may provide a higher level of water mixing during respirometry measurements and theoretically reduce the need for a mixing device, the level of mixing cannot be quantified and may change with diurnal cycles in activity. To ensure consistency across studies without relying on fish activity levels, and to enable accurate assessments of background respiration, it is recommended that all respirometry systems should include an appropriate mixing device. © 2016 The Fisheries Society of the British Isles.

  1. Youth Screen Media Habits and Sleep: Sleep-Friendly Screen Behavior Recommendations for Clinicians, Educators, and Parents.

    PubMed

    Hale, Lauren; Kirschen, Gregory W; LeBourgeois, Monique K; Gradisar, Michael; Garrison, Michelle M; Montgomery-Downs, Hawley; Kirschen, Howard; McHale, Susan M; Chang, Anne-Marie; Buxton, Orfeu M

    2018-04-01

    With the widespread use of portable electronic devices and the normalization of screen media devices in the bedroom, insufficient sleep has become commonplace. In a recent literature review, 90% of included studies found an association between screen media use and delayed bedtime and/or decreased total sleep time. This pervasive phenomenon of pediatric sleep loss has widespread implications. There is a need for basic, translational, and clinical research examining the effects of screen media on sleep loss and health consequences in children and adolescents to educate and motivate clinicians, teachers, parents and youth themselves to foster healthy sleep habits. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Spatially resolving density-dependent screening around a single charged atom in graphene

    NASA Astrophysics Data System (ADS)

    Wong, Dillon; Corsetti, Fabiano; Wang, Yang; Brar, Victor W.; Tsai, Hsin-Zon; Wu, Qiong; Kawakami, Roland K.; Zettl, Alex; Mostofi, Arash A.; Lischner, Johannes; Crommie, Michael F.

    2017-05-01

    Electrons in two-dimensional graphene sheets behave as interacting chiral Dirac fermions and have unique screening properties due to their symmetry and reduced dimensionality. By using a combination of scanning tunneling spectroscopy measurements and theoretical modeling we have characterized how graphene's massless charge carriers screen individual charged calcium atoms. A backgated graphene device configuration has allowed us to directly visualize how the screening length for this system can be tuned with carrier density. Our results provide insight into electron-impurity and electron-electron interactions in a relativistic setting with important consequences for other graphene-based electronic devices.

  3. Combinatorial fabrication and screening of organic light-emitting device arrays

    NASA Astrophysics Data System (ADS)

    Shinar, Joseph; Shinar, Ruth; Zhou, Zhaoqun

    2007-11-01

    The combinatorial fabrication and screening of 2-dimensional (2-d) small molecular UV-violet organic light-emitting device (OLED) arrays, 1-d blue-to-red arrays, 1-d intense white OLED libraries, 1-d arrays to study Förster energy transfer in guest-host OLEDs, and 2-d arrays to study exciplex emission from OLEDs is described. The results demonstrate the power of combinatorial approaches for screening OLED materials and configurations, and for studying their basic properties.

  4. 46 CFR 180.72 - Personal flotation devices carried in addition to life jackets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... emergencies. (b) Wearable marine buoyant devices that include “ski vests,” “boating vests,” and “fishing vests... Commandant, may be carried as additional equipment. (c) Buoyant work vests approved in accordance with § 160...

  5. 46 CFR 180.72 - Personal flotation devices carried in addition to life jackets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... emergencies. (b) Wearable marine buoyant devices that include “ski vests,” “boating vests,” and “fishing vests... Commandant, may be carried as additional equipment. (c) Buoyant work vests approved in accordance with § 160...

  6. 46 CFR 180.72 - Personal flotation devices carried in addition to life jackets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... emergencies. (b) Wearable marine buoyant devices that include “ski vests,” “boating vests,” and “fishing vests... Commandant, may be carried as additional equipment. (c) Buoyant work vests approved in accordance with § 160...

  7. Rapid screening, separation, and detection of hydroxyl radical scavengers from total flavonoids of Ginkgo biloba leaves by chromatography combined with molecular devices.

    PubMed

    Wang, Jing; Zheng, Meizhu; Chen, Lina; Liu, Zhiqiang; Zhang, Yuchi; Liu, Chun-Ming; Liu, Shu

    2016-11-01

    Hydroxyl radicals are the most reactive free radical of human body, a strong contributor to tissue damage. In this study, liquid chromatography coupled to electrospray ionization mass spectrometry was applied to screen and identify hydroxyl radical scavengers from the total flavonoids of Ginkgo biloba leaves, and high-performance counter current chromatography was used to separate and isolate the active compounds. Furthermore, molecular devices were used to determine hydroxyl radical scavenging activities of the obtained hydroxyl radical scavengers and other flavonoids from G. biloba leaves. As a result, six compounds were screened as hydroxyl radical scavengers, but only three flavonoids, namely, rutin, cosmos glycosides and apigenin-7-O-Glu-4'-O-Rha, were isolated successfully from total flavonoids by high-performance counter current chromatography. The purities of the three obtained compounds were over 90%, respectively, as determined by liquid chromatography. Molecular devices with 96-well microplates evaluation indicated that the 50% scavenging concentration values of screened compounds were lower than that of other flavonoids, they performed greater hydroxyl radical scavenging activity, and the evaluation effects were consistent with the liquid chromatography with mass spectrometry screening results. Therefore, chromatography combined with molecular devices is a feasible and an efficient method for systematic screening, identification, isolation, and evaluation of bioactive components in mixture of botanical medicines. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Prevalence of antibiotic resistance genes in the bacterial flora of integrated fish farming environments of Pakistan and Tanzania.

    PubMed

    Shah, Syed Q A; Colquhoun, Duncan J; Nikuli, Hamisi L; Sørum, Henning

    2012-08-21

    The use of a wide variety of antimicrobials in human and veterinary medicine, including aquaculture, has led to the emergence of antibiotic resistant pathogens. In the present study, bacteria from water, sediments, and fish were collected from fish farms in Pakistan and Tanzania with no recorded history of antibiotic use. The isolates were screened for the presence of resistance genes against various antimicrobials used in aquaculture and animal husbandry. Resistant isolates selected by disk diffusion and genotyped by Southern hybridization were further screened by polymerase chain reaction (PCR) and amplicon sequencing. The prominent resistance genes identified encoded tetracycline [tetA(A) and tetA(G)], trimethoprim [dfrA1, dfrA5, dfrA7, dfrA12, and dfrA15], amoxicillin [bla(TEM)], streptomycin [strA-strB], chloramphenicol [cat-1], and erythromycin resistance [mefA]. The int1 gene was found in more than 30% of the bacterial isolates in association with gene cassettes. MAR indices ranged from 0.2 to 1. The bla(NDM-1) gene was not identified in ertapenem resistant isolates. It is hypothesized that integrated fish farming practices utilizing domestic farm and poultry waste along with antibiotic residues from animal husbandry may have contributed to a pool of resistance genes in the aquaculture systems studied.

  9. Integration of magnetic solid phase fishing and off-line two-dimensional high-performance liquid chromatography-diode array detector-mass spectrometry for screening and identification of human serum albumin binders from Radix Astragali.

    PubMed

    Zhang, Yuping; Nie, Mingkun; Shi, Shuyun; You, Qingping; Guo, Junfang; Liu, Liangliang

    2014-03-01

    Radix Astragali is one of the most popular traditional medicinal herb and healthy dietary supplement. Isoflavonoids and astragalosides are the main bioactive ingredients. However, the systematic bioactive component analysis is inadequate so far. Then a facile method based on Fe3O4@SiO2-human serum albumin (Fe3O4@SiO2-HSA) magnetic solid phase fishing integrated with two-dimensional high-performance liquid chromatography-diode array detector-mass spectrometry (2D HPLC-DAD-MS(n)) was developed to fish out and identify HSA binders from Radix Astragali. The immobilized HSA displayed a high stability with 96.2% retained after ten consecutive cycles. 2D HPLC system (size exclusion chromatography×reversed phase chromatography, SEC×RP) were developed and optimised. Forty-seven bioactive compounds including thirty-four isoflavonoids and thirteen astragalosides were screened and identified or tentatively deduced based on their retention time, ultraviolet (UV), accurate molecular weight and diagnostic fragment ions. The results indicated that the integrated method could be widely applied for systematical fishing and identification of bioactive compounds, especially for low-abundance and overlapped compounds, from complex mixtures. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Public health advocacy in action: the case of unproven breast cancer screening in Australia.

    PubMed

    Johnson, Rebecca S; Croager, Emma J; Kameron, Caitlin B; Pratt, Iain S; Vreugdenburg, Thomas D; Slevin, Terry

    2016-09-30

    In recent years, nonmammographic breast imaging devices, such as thermography, electrical impedance scanning and elastography, have been promoted directly to consumers, which has captured the attention of governments, researchers and health organisations. These devices are not supported by evidence and risk undermining existing mammographic breast cancer screening services. During a 5-year period, Cancer Council Western Australia (CCWA) used strategic research combined with legal, policy and media advocacy to contest claims that these devices were proven alternatives to mammography for breast cancer screening. The campaign was successful because it had input from people with public health, academic, clinical and legal backgrounds, and took advantage of existing legal and regulatory avenues. CCWA's experience provides a useful advocacy model for public health practitioners who are concerned about unsafe consumer products, unproven medical devices, and misleading health information and advertising.

  11. Qualitative screening of undesirable compounds from feeds to fish by liquid chromatography coupled to mass spectrometry.

    PubMed

    Nácher-Mestre, Jaime; Ibáñez, María; Serrano, Roque; Pérez-Sánchez, Jaume; Hernández, Félix

    2013-03-06

    This paper describes the development, validation, and application of a rapid screening method for the detection and identification of undesirable organic compounds in aquaculture products. A generic sample treatment was applied without any purification or preconcentration step. After extraction of the samples with acetonitrile/water 80:20 (0.1% formic acid), the extracts were centrifuged and directly injected in the LC-HRMS system, consisting of ultra-high performance liquid chromatography coupled to hybrid quadrupole time-of-flight mass spectrometry (UHPLC-QTOF MS). A qualitative validation was carried out for over 70 representative compounds, including antibiotics, pesticides, and mycotoxins, in fish feed and fish fillets spiked at 20 and 100 μg/kg. At the highest level, the great majority of compounds were detected (using the most abundant ion, typically the protonated molecule) and unequivocally identified (on the basis of the presence of two accurate-mass measured ions). At the 20 μg/kg level, many contaminants could already be detected, although identification using two ions was not fully reached for some of them, mainly in fish feed due to the complexity of this matrix. Subsequent application of this screening methodology to aquaculture samples made it possible to find several compounds from the target list, such as the antibiotic ciprofloxacin, the insecticide pirimiphos-methyl, and the mycotoxins fumonisin B2 and zearalenone. A retrospective analysis of accurate-mass full-spectrum acquisition data provided by QTOF MS was also made, without either reprocessing or injecting the samples. This allowed the detection and tentative identification of other organic undesirables different from those included in the validated list.

  12. An embedded point-of-care malaria screening device for low-resource regions (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Das, Sayantan; Mandal, Subhamoy; Das, Debnath; Malviya, Richa; Garud, Hrushikesh T.; Ray, Ajoy K.

    2016-03-01

    In this article we propose a point-of-care screening device for the detection and identification of malaria parasite, plasmodium vivax, plasmodium malaria, plasmodium oval and plasmodium falciparum with a time frame of 15-20 minute. In our device we can provide 97-98% sensitivity for each species as we are using traditional staining methods for detecting the parasites. In addition, as we are also quantifying the parasites, it is possible to provide an accurate estimate about the malarial stage of the patient. The image processing approach increases the total numbers of samples screened by reducing interventions of trained pathologists. This helps in reducing the delays in screening process arising from increased number of potential cases based on seasonal and local variations. The same reduces mortality rate by faster diagnosis and reduced false negative detections (i.e. increased sensitivity). The system can also be integrated with telemedicine platform to obtain inputs from medical practitioners at tertiary healthcare units for diagnostic decision making. Through this paper, we present the functional prototype of this device containing all the integrated parts. The prototype incorporates image acquisition, image processing, storage, multimedia transmission and reporting environment for a low cost PDA device. It is a portable device capable of scanning slides. The acquired image will be preprocessed and processed to get desired output. The device is capable of transmitting and storing pathological information to database placed in a distant pathological center for further consultation.

  13. St2-80: a new FISH marker for St genome and genome analysis in Triticeae.

    PubMed

    Wang, Long; Shi, Qinghua; Su, Handong; Wang, Yi; Sha, Lina; Fan, Xing; Kang, Houyang; Zhang, Haiqin; Zhou, Yonghong

    2017-07-01

    The St genome is one of the most fundamental genomes in Triticeae. Repetitive sequences are widely used to distinguish different genomes or species. The primary objectives of this study were to (i) screen a new sequence that could easily distinguish the chromosome of the St genome from those of other genomes by fluorescence in situ hybridization (FISH) and (ii) investigate the genome constitution of some species that remain uncertain and controversial. We used degenerated oligonucleotide primer PCR (Dop-PCR), Dot-blot, and FISH to screen for a new marker of the St genome and to test the efficiency of this marker in the detection of the St chromosome at different ploidy levels. Signals produced by a new FISH marker (denoted St 2 -80) were present on the entire arm of chromosomes of the St genome, except in the centromeric region. On the contrary, St 2 -80 signals were present in the terminal region of chromosomes of the E, H, P, and Y genomes. No signal was detected in the A and B genomes, and only weak signals were detected in the terminal region of chromosomes of the D genome. St 2 -80 signals were obvious and stable in chromosomes of different genomes, whether diploid or polyploid. Therefore, St 2 -80 is a potential and useful FISH marker that can be used to distinguish the St genome from those of other genomes in Triticeae.

  14. Wide-Scope Screening Method for Multiclass Veterinary Drug Residues in Fish, Shrimp, and Eel Using Liquid Chromatography-Quadrupole High-Resolution Mass Spectrometry.

    PubMed

    Turnipseed, Sherri B; Storey, Joseph M; Lohne, Jack J; Andersen, Wendy C; Burger, Robert; Johnson, Aaron S; Madson, Mark R

    2017-08-30

    A screening method for veterinary drug residues in fish, shrimp, and eel using LC with a high-resolution MS instrument has been developed and validated. The method was optimized for over 70 test compounds representing a variety of veterinary drug classes. Tissues were extracted by vortex mixing with acetonitrile acidified with 2% acetic acid and 0.2% p-toluenesulfonic acid. A centrifuged portion of the extract was passed through a novel solid phase extraction cartridge designed to remove interfering matrix components from tissue extracts. The eluent was then evaporated and reconstituted for analysis. Data were collected with a quadrupole-Orbitrap high-resolution mass spectrometer using both nontargeted and targeted acquisition methods. Residues were detected on the basis of the exact mass of the precursor and a product ion along with isotope pattern and retention time matching. Semiquantitative data analysis compared MS 1 signal to a one-point extracted matrix standard at a target testing level. The test compounds were detected and identified in salmon, tilapia, catfish, shrimp, and eel extracts fortified at the target testing levels. Fish dosed with selected analytes and aquaculture samples previously found to contain residues were also analyzed. The screening method can be expanded to monitor for an additional >260 veterinary drugs on the basis of exact mass measurements and retention times.

  15. Informing a Tidal Turbine Strike Probability Model through Characterization of Fish Behavioral Response using Multibeam Sonar Output

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bevelhimer, Mark S.; Colby, Jonathan; Adonizio, Mary Ann

    2016-07-31

    One of the most important biological questions facing the marine and hydrokinetic (MHK) energy industry is whether fish and marine mammals that encounter MHK devices are likely to be struck by moving components. For hydrokinetic (HK) devices, i.e., those that generate energy from flowing water, this concern is greatest for large organisms because their increased length increases the probability that they will be struck as they pass through the area of blade sweep and because their increased mass means that the force absorbed if struck is greater and potentially more damaging (Amaral et al. 2015). Key to answering this questionmore » is understanding whether aquatic organisms change their swimming behavior as they encounter a device in a way that decreases their likelihood of being struck and possibly injured by the device. Whether near-field or far-field behavior results in general avoidance of or attraction to HK devices is a significant factor in the possible risk of physical contact with rotating turbine blades (Cada and Bevelhimer 2011).« less

  16. Capillary device refilling. [liquid rocket propellant tank tests

    NASA Technical Reports Server (NTRS)

    Blatt, M. H.; Merino, F.; Symons, E. P.

    1980-01-01

    An analytical and experimental study was conducted dealing with refilling start baskets (capillary devices) with settled fluid. A computer program was written to include dynamic pressure, screen wicking, multiple-screen barriers, standpipe screens, variable vehicle mass for computing vehicle acceleration, and calculation of tank outflow rate and vapor pullthrough height. An experimental apparatus was fabricated and tested to provide data for correlation with the analytical model; the test program was conducted in normal gravity using a scale-model capillary device and ethanol as the test fluid. The test data correlated with the analytical model; the model is a versatile and apparently accurate tool for predicting start basket refilling under actual mission conditions.

  17. Environmental Risk Evaluation System – An Approach to Ranking Risk of Ocean Energy Development on Coastal and Estuarine Environments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Copping, Andrea E.; Hanna, Luke A.; Van Cleve, Frances B.

    Deployment and operation of ocean energy devices does not represent the first foray into industrialization of the oceans; shipping, nearshore development, waste disposal, subsea mining, oil and gas extraction, and large-scale commercial fishing all coexist in various states of equilibrium with the marine environment. In most cases these industries were developed without a clear understanding of the likely outcomes of large-scale development. In virtually every country where the harvest of ocean energy is emerging, regulators and stakeholders require that the industry examine potential effects of devices, minimize the footprint of effects, and provide management measures that either avoid the impactsmore » or mitigate to further reduce the residual impacts. The ERES analysis is based on scenarios that are consistent with sequences of events that lead to adverse impacts, distinguishing between episodic, intermittent, and chronic risks. In the context of ocean energy development, an episodic scenario might involve the exceedingly rare but potentially devastating event of an oil spill from vessels caused by the presence of the device, while vulnerable receptors are present; understanding the risk of such a scenario involves determining the probability of the occurrence by examining factors such as the petroleum content of ocean energy devices, the vessel traffic volume and the proximity of shipping lanes to the ocean energy devices, the reliability of the control measures to avoid an episodic event, and the likely presence of seabirds, marine mammals, or fish that may be affected by oil. In contrast, chronic risk scenarios involve events or circumstances that are continuous, so that risk characterization involves assessing only the severity of the consequences. An example of a chronic risk scenario might be the toxicity to marine organisms due to low-level chemical releases from anti-biofouling paints and coatings that may be used on devices, and the effect that the level of toxicity may have on marine flora and fauna. Between these two extremes are intermittent events, such as encounters between fish and rotating tidal turbine blades that will occur only when fish are present and the tidal device is turning. A key feature of understanding risk is describing the uncertainty associated with the occurrence of an episodic, intermittent, or chronic event, as well as the uncertainty of the resulting consequences.« less

  18. Assessing hydraulic conditions through Francis turbines using an autonomous sensor device

    DOE PAGES

    Fu, Tao; Deng, Zhiqun Daniel; Duncan, Joanne P.; ...

    2016-08-19

    Downstream migratory fish, including some endangered species, can be injured or killed during turbine passage. In this study an autonomous Sensor Fish device was deployed at Arrowrock Dam, Cougar Dam, and Detroit Dam to evaluate the hydraulic conditions and physical stresses that fish experienced when passing through these Francis turbines. Pressure data was used to identify the location of the Sensor Fish and to calculate the nadir pressure and the magnitude and the rate of change in pressure during turbine passage. Acceleration data was used to identify events (collisions or shear) Sensor Fish experienced and to categorize the severity levelmore » (severe, medium, and slight) of each event. The results showed that Sensor Fish experienced severe events mostly in the stay vane/wicket gate region and the runner region. In the stay vane/wicket gate region, almost all severe events were collisions. In the runner region, Sensor fish experienced both severe collisions and severe shear events. Sensor Fish data at three wicket gate opening treatments at Cougar Dam indicated that the wicket gate opening of the Francis turbine can affect the hydraulic conditions in the turbine runner region. Fewer Sensor Fish experienced severe collisions in the turbine runner region at the peak efficiency than at the minimum opening and the maximum opening treatments. Comparisons between the Francis turbines at the three dams and the AHT Kaplan turbine at Wanapum Dam showed that higher percentage of Sensor Fish experienced severe events in the runner region when passing through Francis turbines than the AHT Kaplan turbine. The nadir pressures of the Francis turbines were lower than those of the AHT Kaplan turbine at Wanapum Dam. Both the magnitude and the rate of change in pressure were higher in Francis turbines than in the AHT Kaplan turbine at Wanapum Dam in the runner region. This study can be used to guide future laboratory studies of fish passing through Francis turbine and help the design of more fish-friendly turbines for new hydroelectric dams or the rehabilitations of existing dams.« less

  19. Assessing hydraulic conditions through Francis turbines using an autonomous sensor device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fu, Tao; Deng, Zhiqun Daniel; Duncan, Joanne P.

    Downstream migratory fish, including some endangered species, can be injured or killed during turbine passage. In this study an autonomous Sensor Fish device was deployed at Arrowrock Dam, Cougar Dam, and Detroit Dam to evaluate the hydraulic conditions and physical stresses that fish experienced when passing through these Francis turbines. Pressure data was used to identify the location of the Sensor Fish and to calculate the nadir pressure and the magnitude and the rate of change in pressure during turbine passage. Acceleration data was used to identify events (collisions or shear) Sensor Fish experienced and to categorize the severity levelmore » (severe, medium, and slight) of each event. The results showed that Sensor Fish experienced severe events mostly in the stay vane/wicket gate region and the runner region. In the stay vane/wicket gate region, almost all severe events were collisions. In the runner region, Sensor fish experienced both severe collisions and severe shear events. Sensor Fish data at three wicket gate opening treatments at Cougar Dam indicated that the wicket gate opening of the Francis turbine can affect the hydraulic conditions in the turbine runner region. Fewer Sensor Fish experienced severe collisions in the turbine runner region at the peak efficiency than at the minimum opening and the maximum opening treatments. Comparisons between the Francis turbines at the three dams and the AHT Kaplan turbine at Wanapum Dam showed that higher percentage of Sensor Fish experienced severe events in the runner region when passing through Francis turbines than the AHT Kaplan turbine. The nadir pressures of the Francis turbines were lower than those of the AHT Kaplan turbine at Wanapum Dam. Both the magnitude and the rate of change in pressure were higher in Francis turbines than in the AHT Kaplan turbine at Wanapum Dam in the runner region. This study can be used to guide future laboratory studies of fish passing through Francis turbine and help the design of more fish-friendly turbines for new hydroelectric dams or the rehabilitations of existing dams.« less

  20. Display screen and method of manufacture therefor

    NASA Technical Reports Server (NTRS)

    Dubin, Matthew B. (Inventor); Larson, Brent D. (Inventor)

    2002-01-01

    A screen assembly that combines an angle re-distributing prescreen with a conventional diffusion screen. The prescreen minimizes or eliminates the sensitivity of the screen assembly to projector location. The diffusion screen provides other desirable screen characteristics. Compatible screen structures, along with methods for fabricating high resolution prescreens and methods and devices for maintaining the desired relationship between the prescreen and the diffusion screen are contemplated.

  1. Understanding wax screen-printing: a novel patterning process for microfluidic cloth-based analytical devices.

    PubMed

    Liu, Min; Zhang, Chunsun; Liu, Feifei

    2015-09-03

    In this work, we first introduce the fabrication of microfluidic cloth-based analytical devices (μCADs) using a wax screen-printing approach that is suitable for simple, inexpensive, rapid, low-energy-consumption and high-throughput preparation of cloth-based analytical devices. We have carried out a detailed study on the wax screen-printing of μCADs and have obtained some interesting results. Firstly, an analytical model is established for the spreading of molten wax in cloth. Secondly, a new wax screen-printing process has been proposed for fabricating μCADs, where the melting of wax into the cloth is much faster (∼5 s) and the heating temperature is much lower (75 °C). Thirdly, the experimental results show that the patterning effects of the proposed wax screen-printing method depend to a certain extent on types of screens, wax melting temperatures and melting time. Under optimized conditions, the minimum printing width of hydrophobic wax barrier and hydrophilic channel is 100 μm and 1.9 mm, respectively. Importantly, the developed analytical model is also well validated by these experiments. Fourthly, the μCADs fabricated by the presented wax screen-printing method are used to perform a proof-of-concept assay of glucose or protein in artificial urine with rapid high-throughput detection taking place on a 48-chamber cloth-based device and being performed by a visual readout. Overall, the developed cloth-based wax screen-printing and arrayed μCADs should provide a new research direction in the development of advanced sensor arrays for detection of a series of analytes relevant to many diverse applications. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. 46 CFR 117.72 - Personal flotation devices carried in addition to life jackets.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... devices that include “ski vests,” “boating vests,” and “fishing vests,” approved in accordance with § 160... additional equipment. (c) Buoyant work vests approved in accordance with § 160.053 in subchapter Q of this...

  3. 46 CFR 117.72 - Personal flotation devices carried in addition to life jackets.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... devices that include “ski vests,” “boating vests,” and “fishing vests,” approved in accordance with § 160... additional equipment. (c) Buoyant work vests approved in accordance with § 160.053 in subchapter Q of this...

  4. 46 CFR 117.72 - Personal flotation devices carried in addition to life jackets.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... devices that include “ski vests,” “boating vests,” and “fishing vests,” approved in accordance with § 160... additional equipment. (c) Buoyant work vests approved in accordance with § 160.053 in subchapter Q of this...

  5. Screenometer: a device for sampling vegetative screening in forested areas

    Treesearch

    Victor A. Rudis

    1985-01-01

    A-device for estimating the degree to which vegetation and other obstructions screen forested areas has been adapted to an extensive sampling design for forest surveys. Procedures are recommended to assure that uniform measurements can be made. Examination of sources of sampling variation (observers, points within sampled locations, series of observations within points...

  6. Electronic Device of Didactic and Electrometric Interest for the Study of RLC Circuits.

    ERIC Educational Resources Information Center

    Rodriguez, Angel L. Perez; And Others

    1979-01-01

    Presents a method of studying RLC circuits with the help of the oscilloscope in the XYZ mode, complemented by an electronic device which generates a marker-trace on the screen and which is used to measure frequencies without the need of a reference point on the screen. (Author/GA)

  7. Undergraduate design projects for assistive technology needs: assisted fishing.

    PubMed

    Borrego, Nick; Bilan, Kristi; Gebes, T J; Barrett, S F; Morton, S A

    2012-01-01

    In 2010 the University of Wyoming, College of Engineering and Applied Science was funded for a five year increment of the National Science Foundation’s Research to Aid Persons with Disabilities. This program provides a vital link between challenged individuals who require custom assistive technology devices with senior capstone design students who require challenging, meaningful projects. The program also provides education for our next generation of engineers on the needs of all individuals. In this paper we describe the program organization including project partners in the College and Wyoming Institute for Disabilities (WIND). We also provide a case study of a recently completed project for an assistive fishing device.

  8. Validation of a new algorithm for a quick and easy RT-PCR-based ALK test in a large series of lung adenocarcinomas: Comparison with FISH, immunohistochemistry and next generation sequencing assays.

    PubMed

    Marchetti, Antonio; Pace, Maria Vittoria; Di Lorito, Alessia; Canarecci, Sara; Felicioni, Lara; D'Antuono, Tommaso; Liberatore, Marcella; Filice, Giampaolo; Guetti, Luigi; Mucilli, Felice; Buttitta, Fiamma

    2016-09-01

    Anaplastic Lymphoma Kinase (ALK) gene rearrangements have been described in 3-5% of lung adenocarcinomas (ADC) and their identification is essential to select patients for treatment with ALK tyrosine kinase inhibitors. For several years, fluorescent in situ hybridization (FISH) has been considered as the only validated diagnostic assay. Currently, alternative methods are commercially available as diagnostic tests. A series of 217 ADC comprising 196 consecutive resected tumors and 21 ALK FISH-positive cases from an independent series of 702 ADC were investigated. All specimens were screened by IHC (ALK-D5F3-CDx-Ventana), FISH (Vysis ALK Break-Apart-Abbott) and RT-PCR (ALK RGQ RT-PCR-Qiagen). Results were compared and discordant cases subjected to Next Generation Sequencing. Thirty-nine of 217 samples were positive by the ALK RGQ RT-PCR assay, using a threshold cycle (Ct) cut-off ≤35.9, as recommended. Of these positive samples, 14 were negative by IHC and 12 by FISH. ALK RGQ RT-PCR/FISH discordant cases were analyzed by the NGS assay with results concordant with FISH data. In order to obtain the maximum level of agreement between FISH and ALK RGQ RT-PCR data, we introduced a new scoring algorithm based on the ΔCt value. A ΔCt cut-off level ≤3.5 was used in a pilot series. Then the algorithm was tested on a completely independent validation series. By using the new scoring algorithm and FISH as reference standard, the sensitivity and the specificity of the ALK RGQ RT-PCR(ΔCt) assay were 100% and 100%, respectively. Our results suggest that the ALK RGQ RT-PCR test could be useful in clinical practice as a complementary assay in multi-test diagnostic algorithms or even, if our data will be confirmed in independent studies, as a standalone or screening test for the selection of patients to be treated with ALK inhibitors. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Fluorescent Receptor Binding Assay for Detecting Ciguatoxins in Fish

    PubMed Central

    Hardison, D. Ransom; Holland, William C.; McCall, Jennifer R.; Bourdelais, Andrea J.; Baden, Daniel G.; Darius, H. Taiana; Chinain, Mireille; Tester, Patricia A.; Shea, Damian; Flores Quintana, Harold A.; Morris, James A.; Litaker, R. Wayne

    2016-01-01

    Ciguatera fish poisoning is an illness suffered by > 50,000 people yearly after consumption of fish containing ciguatoxins (CTXs). One of the current methodologies to detect ciguatoxins in fish is a radiolabeled receptor binding assay (RBA(R)). However, the license requirements and regulations pertaining to radioisotope utilization can limit the applicability of the RBA(R) in certain labs. A fluorescence based receptor binding assay (RBA(F)) was developed to provide an alternative method of screening fish samples for CTXs in facilities not certified to use radioisotopes. The new assay is based on competition binding between CTXs and fluorescently labeled brevetoxin-2 (BODIPY®- PbTx-2) for voltage-gated sodium channel receptors at site 5 instead of a radiolabeled brevetoxin. Responses were linear in fish tissues spiked from 0.1 to 1.0 ppb with Pacific ciguatoxin-3C (P-CTX-3C) with a detection limit of 0.075 ppb. Carribean ciguatoxins were confirmed in Caribbean fish by LC-MS/MS analysis of the regional biomarker (C-CTX-1). Fish (N = 61) of six different species were screened using the RBA(F). Results for corresponding samples analyzed using the neuroblastoma cell-based assay (CBA-N2a) correlated well (R2 = 0.71) with those of the RBA(F), given the low levels of CTX present in positive fish. Data analyses also showed the resulting toxicity levels of P-CTX-3C equivalents determined by CBA-N2a were consistently lower than the RBA(F) affinities expressed as % binding equivalents, indicating that a given amount of toxin bound to the site 5 receptors translates into corresponding lower cytotoxicity. Consequently, the RBA(F), which takes approximately two hours to perform, provides a generous estimate relative to the widely used CBA-N2a which requires 2.5 days to complete. Other RBA(F) advantages include the long-term (> 5 years) stability of the BODIPY®- PbTx-2 and having similar results as the commonly used RBA(R). The RBA(F) is cost-effective, allows high sample throughput, and is well-suited for routine CTX monitoring programs. PMID:27073998

  10. Ciguatera fish poisoning in Hong Kong--a 10-year perspective on the class of ciguatoxins.

    PubMed

    Wong, Chun-Kwan; Hung, Patricia; Lo, Janice Y C

    2014-08-01

    The present study used liquid chromatography-tandem mass spectrometry (LC-MS/MS) to investigate retrospectively ciguatoxin (CTX)-positive samples as determined by mouse bioassay (MBA) in the past 10 years in Hong Kong. The results showed that Pacific CTXs (P-CTX-1, -2 and -3) were the most commonly observed toxins found in the samples, indicating Pacific Ocean areas as the most important origin of ciguatera fish poisoning. Clinical diagnosis from ciguatera patients also revealed the predominance of neurological illnesses in most cases, supporting intoxication of Pacific origin. This study demonstrated the ability of laboratory analysis to identify and quantify Pacific CTXs in suspected fish samples, so as to support the clinical diagnosis of ciguatera. Comparative analysis (Student's t-test and Spearman's rank correlation analysis) on the two CTX detection methods showed approximate linearity for overall P-CTXs (P-CTX-1, -2 and -3)/P-CTX-1 alone as derived by LC-MS/MS and total toxicity levels (P-CTX-1 equivalent) as determined by MBA. The LC-MS/MS method coupled with the rapid extraction method could allow the detection of trace amount of CTXs at levels below the clinically relevant limit, 0.1 ppb P-CTX-1 in fish flesh. For practical application, the adoption of a two-tiered approach for testing, chemical analysis by LC-MS/MS for toxic fish screening, coupled with biological assay by MBA for final toxicity confirmation, was proposed for first-line screening of CTX in potentially contaminated fish samples in the market, with an aim to minimizing the use of laboratory mice and at the same time providing reasonably effective means for routine analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Prospective and clinical validation of ALK immunohistochemistry: results from the phase I/II study of alectinib for ALK-positive lung cancer (AF-001JP study)

    PubMed Central

    Takeuchi, K.; Togashi, Y.; Kamihara, Y.; Fukuyama, T.; Yoshioka, H.; Inoue, A.; Katsuki, H.; Kiura, K.; Nakagawa, K.; Seto, T.; Maemondo, M.; Hida, T.; Harada, M.; Ohe, Y.; Nogami, N.; Yamamoto, N.; Nishio, M.; Tamura, T.

    2016-01-01

    Background Anaplastic lymphoma kinase (ALK) fusions need to be accurately and efficiently detected for ALK inhibitor therapy. Fluorescence in situ hybridization (FISH) remains the reference test. Although increasing data are supporting that ALK immunohistochemistry (IHC) is highly concordant with FISH, IHC screening needed to be clinically and prospectively validated. Patients and methods In the AF-001JP trial for alectinib, 436 patients were screened for ALK fusions through IHC (n = 384) confirmed with FISH (n = 181), multiplex RT-PCR (n = 68), or both (n = 16). IHC results were scored with iScore. Result ALK fusion was positive in 137 patients and negative in 250 patients. Since the presence of cancer cells in the samples for RT-PCR was not confirmed, ALK fusion negativity could not be ascertained in 49 patients. IHC interpreted with iScore showed a 99.4% (173/174) concordance with FISH. All 41 patients who had iScore 3 and were enrolled in phase II showed at least 30% tumor reduction with 92.7% overall response rate. Two IHC-positive patients with an atypical FISH pattern responded to ALK inhibitor therapy. The reduction rate was not correlated with IHC staining intensity. Conclusions Our study showed (i) that when sufficiently sensitive and appropriately interpreted, IHC can be a stand-alone diagnostic for ALK inhibitor therapies; (ii) that when atypical FISH patterns are accompanied by IHC positivity, the patients should be considered as candidates for ALK inhibitor therapies, and (iii) that the expression level of ALK fusion is not related to the level of response to ALK inhibitors and is thus not required for patient selection. Registration number JapicCTI-101264 (This study is registered with the Japan Pharmaceutical Information Center). PMID:26487585

  12. Fluorescent ligand fishing combination with in-situ imaging and characterizing to screen Hsp 90 inhibitors from Curcuma longa L. based on InP/ZnS quantum dots embedded mesoporous nanoparticles.

    PubMed

    Hu, Yue; Fu, Anchen; Miao, Zhaoyi; Zhang, Xiaojing; Wang, Tianlin; Kang, An; Shan, Jinjun; Zhu, Dong; Li, Wei

    2018-02-01

    Although ligand fishing has been shown to be an efficient technique for the identification of bioactive components from complex mixtures such as natural products, it cannot be applied to biomedical image processing. Herein, a specific fluorescent ligand fishing combined with in situ imaging approach is presented for the identification of heat shock protein 90 (Hsp 90) inhibitors from complex matrixes, Curcuma longa L., using N-terminus immobilized Hsp 90α functionalized InP/ZnS quantum dots embedded mesoporous nanoparticles (i.e. Hsp 90α (NT)-FQDNs) as extraction sorbents and fluorescent tracer. The fished ligands were identified by liquid chromatography time-of-flight/mass spectrometry (LC-TOF/MS) and gas chromatography-mass spectrometry (GC-MS). Moreover, in situ imaging by confocal laser scanning microscopy (CLSM) was applied for evaluating the effect of fished-ligands on bioactivity-induced apoptosis morphologically in HeLa cells. MTT assay verified the bioactivity of the ligands and molecular docking results further provided convincing information to verify the feasible binding mode between ligands and protein. Twelve ligands as potential Hsp 90 inhibitors were ultimately fished and identified from Curcuma longa L. crude extracts. The proposed approach based on Hsp 90α functionalized nanocomposites is superior in the combination of highly specific screening efficiency and concurrent visual in situ imaging, which could have great promise for the development of other plant-derived Hsp 90 inhibitors, and providing a rapid and reliable platform for discovering biologically active molecules in natural products. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Contaminants assessment in the coral reefs of Virgin Islands National Park and Virgin Islands Coral Reef National Monument

    USGS Publications Warehouse

    Bargar, Timothy A.; Garrison, Virginia H.; Alvarez, David A.; Echols, Kathy

    2013-01-01

    Coral, fish, plankton, and detritus samples were collected from coral reefs in Virgin Islands National Park (VIIS) and Virgin Islands Coral Reef National Monument (VICR) to assess existing contamination levels. Passive water sampling using polar organic chemical integrative samplers (POCIS) and semi-permeable membrane devices found a few emerging pollutants of concern (DEET and galaxolide) and polynuclear aromatic hydrocarbons. Very little persistent organic chemical contamination was detected in the tissue or detritus samples. Detected contaminants were at concentrations below those reported to be harmful to aquatic organisms. Extracts from the POCIS were subjected to the yeast estrogen screen (YES) to assess potential estrogenicity of the contaminant mixture. Results of the YES (estrogen equivalency of 0.17–0.31 ng/L 17-β-estradiol) indicated a low estrogenicity likelihood for contaminants extracted from water. Findings point to low levels of polar and non-polar organic contaminants in the bays sampled within VICR and VIIS.

  14. Amperometric Biosensor Based on Diamine Oxidase/Platinum Nanoparticles/Graphene/Chitosan Modified Screen-Printed Carbon Electrode for Histamine Detection.

    PubMed

    Apetrei, Irina Mirela; Apetrei, Constantin

    2016-03-24

    This work describes the development and optimization studies of a novel biosensor employed in the detection and quantification of histamine in freshwater fish samples. The proposed biosensor is based on a modified carbon screen-printed electrode with diamineoxidase, graphene and platinum nanoparticles, which detects the hydrogen peroxide formed by the chemical process biocatalysed by the enzyme diamine oxidase and immobilized onto the nanostructurated surface of the receptor element. The amperometric measurements with the biosensor have been implemented in buffer solution of pH 7.4, applying an optimal low potential of +0.4 V. The novel biosensor shows high sensitivity (0.0631 μA·μM), low detection limit (2.54 × 10(-8) M) and a broad linear domain from 0.1 to 300 μM. The applicability in natural complex samples and the analytical parameters of this enzyme sensor have been performed in the quantification of histamine in freshwater fish. An excellent correlation among results achieved with the developed biosensor and results found with the standard method for all freshwater fish samples has been achieved.

  15. Amperometric Biosensor Based on Diamine Oxidase/Platinum Nanoparticles/Graphene/Chitosan Modified Screen-Printed Carbon Electrode for Histamine Detection

    PubMed Central

    Apetrei, Irina Mirela; Apetrei, Constantin

    2016-01-01

    This work describes the development and optimization studies of a novel biosensor employed in the detection and quantification of histamine in freshwater fish samples. The proposed biosensor is based on a modified carbon screen-printed electrode with diamineoxidase, graphene and platinum nanoparticles, which detects the hydrogen peroxide formed by the chemical process biocatalysed by the enzyme diamine oxidase and immobilized onto the nanostructurated surface of the receptor element. The amperometric measurements with the biosensor have been implemented in buffer solution of pH 7.4, applying an optimal low potential of +0.4 V. The novel biosensor shows high sensitivity (0.0631 μA·μM), low detection limit (2.54 × 10−8 M) and a broad linear domain from 0.1 to 300 μM. The applicability in natural complex samples and the analytical parameters of this enzyme sensor have been performed in the quantification of histamine in freshwater fish. An excellent correlation among results achieved with the developed biosensor and results found with the standard method for all freshwater fish samples has been achieved. PMID:27023541

  16. Clinical and psychological effects of excessive screen time on children.

    PubMed

    Domingues-Montanari, Sophie

    2017-04-01

    Over recent years, screen time has become a more complicated concept, with an ever-expanding variety of electronic media devices available throughout the world. Television remains the predominant type of screen-based activity among children. However, computer use, video games and ownership of devices, such as tablets and smart phones, are occurring from an increasingly young age. Screen time, in particular, television viewing, has been negatively associated with the development of physical and cognitive abilities, and positively associated with obesity, sleep problems, depression and anxiety. The physiological mechanisms that underlie the adverse health outcomes related to screen time and the relative contributions of different types of screen and media content to specific health outcomes are unclear. This review discusses the positive and negative effects of screen time on the physiological and psychological development of children. Furthermore, recommendations are offered to parents and clinicians. © 2017 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  17. Status of downstream fish passage at hydroelectric projects in the northeast, USA

    USGS Publications Warehouse

    Odeh, Mufeed; Orvis, Curtis

    1997-01-01

    In the northeastern United States several guidance, protection, and conveyance methods have been employed to assist downstream migrating fish. Overlay racks, standard bar racks with close spacing, louvers, curtain walls, guide walls, netting, and other means have been used to guide and protect fish from entrainment. The design process of these facilities comprises consideration of various factors, including flow approach, attraction flow, guidance and protection devices, bypass location, conveyance mechanism, and plunge pool conditions. This paper presents the status of the design criteria for downstream fish passage facilities at hydroelectric sites in the northeast part of the United States. Examples of existing facilities are given.

  18. FPGA-based sleep apnea screening device for home monitoring.

    PubMed

    Al-Ashmouny, K haledM; Hamed, Hisham M; Morsy, Ahmed A

    2006-01-01

    We present the hardware design of an FPGA-based portable device for home screening of sleep apnea syndromes. The device is simple to use, inexpensive, and uses only three signals, namely the nasal air flow and the thorax and abdomen effort signals. The device hardware stores data of overnight sleep on a Secure Digital card. At the clinic, the sleep specialist reads in the stored data and uses an algorithm for the detection and classification of sleep apnea. The device is fairly low-cost and may help spread the ability to diagnose more cases of sleep apnea. Most sleep apnea cases currently go undiagnosed because of cost and practicality limitations of overnight polysomnography at sleep labs.

  19. Screening and classification of ceramic powders

    NASA Technical Reports Server (NTRS)

    Miwa, S.

    1983-01-01

    A summary is given of the classification technology of ceramic powders. Advantages and disadvantages of the wet and dry screening and classification methods are discussed. Improvements of wind force screening devices are described.

  20. Evaluation of the on-site immunoassay drug-screening device Triage-TOX in routine forensic autopsy.

    PubMed

    Tominaga, Mariko; Michiue, Tomomi; Maeda, Hitoshi

    2015-11-01

    Instrumental identification of drugs with quantification is essential in forensic toxicology, while on-site immunoassay urinalysis drug-screening devices conveniently provide preliminary information when adequately used. However, suitable or sufficient urine specimens are not always available. The present study evaluated the efficacy of a new on-site immunoassay drug-screening device Triage-TOX (Alere Inc., San Diego, CA, USA), which has recently been developed to provide objective data on the one-step automated processor, using 51 urine and 19 pericardial fluid samples from 66 forensic autopsy cases, compared with Triage-Drug of Abuse (DOA) and Monitect-9. For benzodiazepines, the positive predictive value and specificity of Triage-TOX were higher than those of Triage-DOA; however, sensitivity was higher with Monitect-9, despite frequent false-positives. The results for the other drugs with the three devices also included a few false-negatives and false-positives. These observations indicate the applicability of Triage-TOX in preliminary drug screening using urine or alternative materials in routine forensic autopsy, when a possible false-negative is considered, especially for benzodiazepines, providing objective information; however, the combined use of another device such as Monitect-9 can help minimize misinterpretation prior to instrumental analysis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  1. From One to Many Boxes: Mobile Devices as Primary and Secondary Screens

    NASA Astrophysics Data System (ADS)

    Cesar, Pablo; Knoche, Hendrik; Bulterman, Dick C. A.

    This chapter looks at the current changing habits on audiovisual content consumption at home, with special focus on potential uses of mobile devices. Standard television plus a remote control impose a use that is too coarse to support the various personal needs of people, while mobile devices open new possibilities from engagement and immersion into content and deliberately controlled disengagement with others to providing a screen that can be offered to include others in sharing experiences in a huddled setting.

  2. 50 CFR 27.72 - Audio equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false Audio equipment. 27.72 Section 27.72 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) THE... Audio equipment. The operation or use of audio devices including radios, recording and playback devices...

  3. 50 CFR 27.72 - Audio equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 8 2011-10-01 2011-10-01 false Audio equipment. 27.72 Section 27.72 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) THE... Audio equipment. The operation or use of audio devices including radios, recording and playback devices...

  4. 50 CFR 27.72 - Audio equipment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 50 Wildlife and Fisheries 9 2012-10-01 2012-10-01 false Audio equipment. 27.72 Section 27.72 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) THE... Audio equipment. The operation or use of audio devices including radios, recording and playback devices...

  5. Evaluation of Fish Passage Conditions for Juvenile Salmonids Using Sensor Fish at Detroit Dam, Oregon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duncan, Joanne P.

    2010-01-29

    Fish passage conditions through two spillways at Detroit Dam on the North Santiam River in Oregon were evaluated by Pacific Northwest National Laboratory for the U.S. Army Corps of Engineers (USACE), Portland District, using Sensor Fish devices. The objective of the study was to describe and compare passage exposure conditions through Spillbay 3 and Spillbay 6 at 1.5- and 3.5-ft gate openings, identifying potential fish injury regions of the routes. The study was performed in July 2009, concurrent with HI-Z balloon-tag studies by Normandeau Associates, Inc. Sensor Fish and live fish were deployed at elevations approximately 3 ft above structuremore » at depths determined using a computational fluid dynamics model. Data collected were analyzed to estimate 1) exposure conditions, particularly exposure to severe collision and shear events by passage route sub-regions; 2) differences in passage conditions between passage routes; and 3) relationships to live-fish injury and mortality data estimates.« less

  6. Emerging human pathogen Acinetobacter baumannii in the natural aquatic environment: a public health risk?

    PubMed

    Dekić, Svjetlana; Klobučar, Göran; Ivanković, Tomislav; Zanella, Davor; Vucić, Matej; Bourdineaud, Jean-Paul; Hrenović, Jasna

    2018-05-08

    Bacterium Acinetobacter baumannii is an emerging human pathogen whose presence in the aquatic environment raises the issue of public health risk. Fish colonization represents the potential route of pathogen transmission to humans. The aim was to examine the colonization of A. baumannii to freshwater fish Poecilia reticulata. An extensively drug-resistant A. baumannii was tested at three concentrations in natural spring water. Additionally, 70 fish from the Sava River (Croatia) were screened for the presence of A. baumannii, which was not found in gill swabs or analysed gut. The colonization potential of A. baumannii in freshwater fish is dependent upon its concentration in surrounding water. The low concentration of A. baumannii in natural waters represents low colonization potential of freshwater fish. The risk for public health exists in closed water bodies where there is constant inflow of water polluted by A. baumannii in concentrations above 3 log CFU mL -1 .

  7. Characterization of fish hold effluent discharged from commercial fishing vessels into harbor waters.

    PubMed

    Albert, Ryan J; McLaughlin, Christine; Falatko, Debra

    2014-10-15

    Fish hold effluent and the effluent produced from the cleaning of fish holds may contain organic material resulting from the degradation of seafood and cleaning products (e.g., soaps and detergents). This effluent is often discharged by vessels into near shore waters and, therefore, could have the potential to contribute to water pollution in bays and estuaries. We characterized effluent from commercial fishing vessels with holds containing refrigerated seawater, ice slurry, or chipped ice. Concentrations of trace heavy metals, wet chemistry parameters, and nutrients in effluent were compared to screening benchmarks to determine if there is a reasonable potential for effluent discharge to contribute to nonattainment of water quality standards. Most analytes (67%) exceeded their benchmark concentration and, therefore, may have the potential to pose risk to human health or the environment if discharges are in significant quantities or there are many vessels discharging in the same areas. Published by Elsevier Ltd.

  8. Opposite selection on behavioural types by active and passive fishing gears in a simulated guppy Poecilia reticulata fishery.

    PubMed

    Diaz Pauli, B; Wiech, M; Heino, M; Utne-Palm, A C

    2015-03-01

    This study assessed whether fishing gear was selective on behavioural traits, such as boldness and activity, and how this was related with a productivity trait, growth. Female guppies Poecilia reticulata were screened for their behaviour on the shy-bold axis and activity, and then tested whether they were captured differently by passive and active fishing gear, here represented by a trap and a trawl. Both gears were selective on boldness; bold individuals were caught faster by the trap, but escaped the trawl more often. Boldness and gear vulnerability showed weak correlations with activity and growth. The results draw attention to the importance of the behavioural dimension of fishing: selective fishing on behavioural traits will change the trait composition of the population, and might eventually affect resilience and fishery productivity. © 2015 The Fisheries Society of the British Isles.

  9. Reverse screening methods to search for the protein targets of chemopreventive compounds

    NASA Astrophysics Data System (ADS)

    Huang, Hongbin; Zhang, Guigui; Zhou, Yuquan; Lin, Chenru; Chen, Suling; Lin, Yutong; Mai, Shangkang; Huang, Zunnan

    2018-05-01

    This article is a systematic review of reverse screening methods used to search for the protein targets of chemopreventive compounds or drugs. Typical chemopreventive compounds include components of traditional Chinese medicine, natural compounds and Food and Drug Administration (FDA)-approved drugs. Such compounds are somewhat selective but are predisposed to bind multiple protein targets distributed throughout diverse signaling pathways in human cells. In contrast to conventional virtual screening, which identifies the ligands of a targeted protein from a compound database, reverse screening is used to identify the potential targets or unintended targets of a given compound from a large number of receptors by examining their known ligands or crystal structures. This method, also known as in silico or computational target fishing, is highly valuable for discovering the target receptors of query molecules from terrestrial or marine natural products, exploring the molecular mechanisms of chemopreventive compounds, finding alternative indications of existing drugs by drug repositioning, and detecting adverse drug reactions and drug toxicity. Reverse screening can be divided into three major groups: shape screening, pharmacophore screening and reverse docking. Several large software packages, such as Schrödinger and Discovery Studio; typical software/network services such as ChemMapper, PharmMapper, idTarget and INVDOCK; and practical databases of known target ligands and receptor crystal structures, such as ChEMBL, BindingDB and the Protein Data Bank (PDB), are available for use in these computational methods. Different programs, online services and databases have different applications and constraints. Here, we conducted a systematic analysis and multilevel classification of the computational programs, online services and compound libraries available for shape screening, pharmacophore screening and reverse docking to enable non-specialist users to quickly learn and grasp the types of calculations used in protein target fishing. In addition, we review the main features of these methods, programs and databases and provide a variety of examples illustrating the application of one or a combination of reverse screening methods for accurate target prediction.

  10. Reverse Screening Methods to Search for the Protein Targets of Chemopreventive Compounds.

    PubMed

    Huang, Hongbin; Zhang, Guigui; Zhou, Yuquan; Lin, Chenru; Chen, Suling; Lin, Yutong; Mai, Shangkang; Huang, Zunnan

    2018-01-01

    This article is a systematic review of reverse screening methods used to search for the protein targets of chemopreventive compounds or drugs. Typical chemopreventive compounds include components of traditional Chinese medicine, natural compounds and Food and Drug Administration (FDA)-approved drugs. Such compounds are somewhat selective but are predisposed to bind multiple protein targets distributed throughout diverse signaling pathways in human cells. In contrast to conventional virtual screening, which identifies the ligands of a targeted protein from a compound database, reverse screening is used to identify the potential targets or unintended targets of a given compound from a large number of receptors by examining their known ligands or crystal structures. This method, also known as in silico or computational target fishing, is highly valuable for discovering the target receptors of query molecules from terrestrial or marine natural products, exploring the molecular mechanisms of chemopreventive compounds, finding alternative indications of existing drugs by drug repositioning, and detecting adverse drug reactions and drug toxicity. Reverse screening can be divided into three major groups: shape screening, pharmacophore screening and reverse docking. Several large software packages, such as Schrödinger and Discovery Studio; typical software/network services such as ChemMapper, PharmMapper, idTarget, and INVDOCK; and practical databases of known target ligands and receptor crystal structures, such as ChEMBL, BindingDB, and the Protein Data Bank (PDB), are available for use in these computational methods. Different programs, online services and databases have different applications and constraints. Here, we conducted a systematic analysis and multilevel classification of the computational programs, online services and compound libraries available for shape screening, pharmacophore screening and reverse docking to enable non-specialist users to quickly learn and grasp the types of calculations used in protein target fishing. In addition, we review the main features of these methods, programs and databases and provide a variety of examples illustrating the application of one or a combination of reverse screening methods for accurate target prediction.

  11. Reverse Screening Methods to Search for the Protein Targets of Chemopreventive Compounds

    PubMed Central

    Huang, Hongbin; Zhang, Guigui; Zhou, Yuquan; Lin, Chenru; Chen, Suling; Lin, Yutong; Mai, Shangkang; Huang, Zunnan

    2018-01-01

    This article is a systematic review of reverse screening methods used to search for the protein targets of chemopreventive compounds or drugs. Typical chemopreventive compounds include components of traditional Chinese medicine, natural compounds and Food and Drug Administration (FDA)-approved drugs. Such compounds are somewhat selective but are predisposed to bind multiple protein targets distributed throughout diverse signaling pathways in human cells. In contrast to conventional virtual screening, which identifies the ligands of a targeted protein from a compound database, reverse screening is used to identify the potential targets or unintended targets of a given compound from a large number of receptors by examining their known ligands or crystal structures. This method, also known as in silico or computational target fishing, is highly valuable for discovering the target receptors of query molecules from terrestrial or marine natural products, exploring the molecular mechanisms of chemopreventive compounds, finding alternative indications of existing drugs by drug repositioning, and detecting adverse drug reactions and drug toxicity. Reverse screening can be divided into three major groups: shape screening, pharmacophore screening and reverse docking. Several large software packages, such as Schrödinger and Discovery Studio; typical software/network services such as ChemMapper, PharmMapper, idTarget, and INVDOCK; and practical databases of known target ligands and receptor crystal structures, such as ChEMBL, BindingDB, and the Protein Data Bank (PDB), are available for use in these computational methods. Different programs, online services and databases have different applications and constraints. Here, we conducted a systematic analysis and multilevel classification of the computational programs, online services and compound libraries available for shape screening, pharmacophore screening and reverse docking to enable non-specialist users to quickly learn and grasp the types of calculations used in protein target fishing. In addition, we review the main features of these methods, programs and databases and provide a variety of examples illustrating the application of one or a combination of reverse screening methods for accurate target prediction. PMID:29868550

  12. The development of an observational screening tool to assess safe, effective and appropriate walking aid use in people with multiple sclerosis.

    PubMed

    Eitzen, Abby; Finlayson, Marcia; Carolan-Laing, Leanne; Nacionales, Arthur Junn; Walker, Christie; O'Connor, Josephine; Asano, Miho; Coote, Susan

    2017-08-01

    The purpose of this study was to identify potential items for an observational screening tool to assess safe, effective and appropriate walking aid use among people with multiple sclerosis (MS). Such a tool is needed because of the association between fall risk and mobility aid use in this population. Four individuals with MS were videotaped using a one or two straight canes, crutches or a rollator in different settings. Seventeen health care professionals from Canada, Ireland and the United States were recruited, and viewed the videos, and were then interviewed about the use of the devices by the individuals in the videos. Interview questions addressed safety, effectiveness and appropriateness of the device in the setting. Data were analyzed qualitatively. Coding consistency across raters was evaluated and confirmed. Nineteen codes were identified as possible items for the screening tool. The most frequent issues raised regardless of setting and device were "device used for duration/abandoned", "appropriate device", "balance and stability", "device technique", "environmental modification" and "hands free." With the identification of a number of potential tool items, researchers can now move forward with the development of the tool. This will involve consultation with both healthcare professionals and people with MS. Implications for rehabilitation Falls among people with multiple sclerosis are associated with mobility device use and use of multiple devices is associated with greater falls risk. The ability to assess for safe, effective and efficient use of walking aids is therefore important, no tools currently exist for this purpose. The codes arising from this study will be used to develop a screening tool for safe, effective and efficient walking aid use with the aim of reducing falls risk.

  13. Atmospherically Deposited PBDEs, Pesticides, PCBs, and PAHs in Western US National Park Fish: Concentrations and Consumption Guidelines

    PubMed Central

    Ackerman, Luke K.; Schwindt, Adam R.; Simonich, Staci L.; Koch, Dan C.; Blett, Tamara F.; Schreck, Carl B.; Kent, Michael L.; Landers, Dixon H.

    2014-01-01

    Concentrations of polybrominated diphenyl ethers (PBDEs), pesticides, polychlorinated biphenyls (PCBs), and polycyclic aromatic hydrocarbons were measured in 136 fish from 14 remote lakes in 8 western US National Parks/Preserves between 2003 and 2005 and compared to human and wildlife contaminant health thresholds. A sensitive (median detection limit −18 pg/g wet weight), efficient (61% recovery at 8 ng/g), reproducible (4.1 %RSD), and accurate (7 % deviation from SRM) analytical method was developed and validated for these analyses. Concentrations of PCBs, hexachlorobenzene, hexachlorocyclohexanes, DDTs and chlordanes in western US fish were comparable to or lower than mountain fish recently collected from Europe, Canada, and Asia. Dieldrin and PBDE concentrations were higher than recent measurements in mountain fish and Pacific Ocean salmon. Concentrations of most contaminants in western US fish were 1–6 orders of magnitude below calculated recreational fishing contaminant health thresholds. However, contaminant concentrations exceeded subsistence fishing cancer screening values in 8 of 14 lakes. Average contaminant concentrations in fish exceeded wildlife contaminant health thresholds for piscivorous mammals in 5 lakes, and piscivorous birds in all 14 lakes. These results indicate that atmospherically deposited organic contaminants can accumulate in high elevation fish, reaching concentrations relevant to human and wildlife health. PMID:18504962

  14. 2015 Epidemic of Severe Streptococcus agalactiae Sequence Type 283 Infections in Singapore Associated With the Consumption of Raw Freshwater Fish: A Detailed Analysis of Clinical, Epidemiological, and Bacterial Sequencing Data.

    PubMed

    Kalimuddin, Shirin; Chen, Swaine L; Lim, Cindy T K; Koh, Tse Hsien; Tan, Thean Yen; Kam, Michelle; Wong, Christopher W; Mehershahi, Kurosh S; Chau, Man Ling; Ng, Lee Ching; Tang, Wen Ying; Badaruddin, Hishamuddin; Teo, Jeanette; Apisarnthanarak, Anucha; Suwantarat, Nuntra; Ip, Margaret; Holden, Matthew T G; Hsu, Li Yang; Barkham, Timothy

    2017-05-15

    Streptococcus agalactiae (group B Streptococcus [GBS]) has not been described as a foodborne pathogen. However, in 2015, a large outbreak of severe invasive sequence type (ST) 283 GBS infections in adults epidemiologically linked to the consumption of raw freshwater fish occurred in Singapore. We attempted to determine the scale of the outbreak, define the clinical spectrum of disease, and link the outbreak to contaminated fish. Time-series analysis was performed on microbiology laboratory data. Food handlers and fishmongers were screened for enteric carriage of GBS. A retrospective cohort study was conducted to assess differences in demographic and clinical characteristics of patients with invasive ST283 and non-ST283 infections. Whole-genome sequencing was performed on human and fish ST283 isolates from Singapore, Thailand, and Hong Kong. The outbreak was estimated to have started in late January 2015. Within the study cohort of 408 patients, ST283 accounted for 35.8% of cases. Patients with ST283 infection were younger and had fewer comorbidities but were more likely to develop meningoencephalitis, septic arthritis, and spinal infection. Of 82 food handlers and fishmongers screened, none carried ST283. Culture of 43 fish samples yielded 13 ST283-positive samples. Phylogenomic analysis of 161 ST283 isolates from humans and fish revealed they formed a tight clade distinguished by 93 single-nucleotide polymorphisms. ST283 is a zoonotic GBS clone associated with farmed freshwater fish, capable of causing severe disease in humans. It caused a large foodborne outbreak in Singapore and poses both a regional and potentially more widespread threat. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.

  15. First Description of Two Sequence Type 2 Acinetobacter baumannii Isolates Carrying OXA-23 Carbapenemase in Pagellus acarne Fished from the Mediterranean Sea near Bejaia, Algeria

    PubMed Central

    Brahmi, Soumia; Touati, Abdelaziz; Cadière, Axelle; Djahmi, Nassima; Pantel, Alix; Sotto, Albert; Dunyach-Remy, Catherine

    2016-01-01

    To determine the occurrence of carbapenem-resistant Acinetobacter baumannii in fish fished from the Mediterranean Sea near the Bejaia coast (Algeria), we studied 300 gills and gut samples that had been randomly and prospectively collected during 1 year. After screening on selective agar media, using PCR arrays and whole-genome sequencing, we identified for the first time two OXA-23-producing A. baumannii strains belonging to the widespread sequence type 2 (ST2)/international clone II and harboring aminoglycoside-modifying enzymes [aac(6′)-Ib and aac(3′)-I genes]. PMID:26787693

  16. Self-Sampling for Human Papillomavirus Testing among Non-Attenders Increases Attendance to the Norwegian Cervical Cancer Screening Programme

    PubMed Central

    Enerly, Espen; Bonde, Jesper; Schee, Kristina; Pedersen, Helle; Lönnberg, Stefan; Nygård, Mari

    2016-01-01

    Increasing attendance to screening offers the best potential for improving the effectiveness of well-established cervical cancer screening programs. Self-sampling at home for human papillomavirus (HPV) testing as an alternative to a clinical sampling can be a useful policy to increase attendance. To determine whether self-sampling improves screening attendance for women who do not regularly attend the Norwegian Cervical Cancer Screening Programme (NCCSP), 800 women aged 25–69 years in the Oslo area who were due to receive a 2nd reminder to attend regular screening were randomly selected and invited to be part of the intervention group. Women in this group received one of two self-sampling devices, Evalyn Brush or Delphi Screener. To attend screening, women in the intervention group had the option of using the self-sampling device (self-sampling subgroup) or visiting their physician for a cervical smear. Self-sampled specimens were split and analyzed for the presence of high-risk (hr) HPV by the CLART® HPV2 test and the digene® Hybrid Capture (HC)2 test. The control group consisted of 2593 women who received a 2nd reminder letter according to the current guidelines of the NCCSP. The attendance rates were 33.4% in the intervention group and 23.2% in the control group, with similar attendance rates for both self-sampling devices. Women in the self-sampling subgroup responded favorably to both self-sampling devices and cited not remembering receiving a call for screening as the most dominant reason for previous non-attendance. Thirty-two of 34 (94.1%) hrHPV-positive women in the self-sampling subgroup attended follow-up. In conclusion, self-sampling increased attendance rates and was feasible and well received. This study lends further support to the proposal that self-sampling may be a valuable alternative for increasing cervical cancer screening coverage in Norway. PMID:27073929

  17. Self-Sampling for Human Papillomavirus Testing among Non-Attenders Increases Attendance to the Norwegian Cervical Cancer Screening Programme.

    PubMed

    Enerly, Espen; Bonde, Jesper; Schee, Kristina; Pedersen, Helle; Lönnberg, Stefan; Nygård, Mari

    2016-01-01

    Increasing attendance to screening offers the best potential for improving the effectiveness of well-established cervical cancer screening programs. Self-sampling at home for human papillomavirus (HPV) testing as an alternative to a clinical sampling can be a useful policy to increase attendance. To determine whether self-sampling improves screening attendance for women who do not regularly attend the Norwegian Cervical Cancer Screening Programme (NCCSP), 800 women aged 25-69 years in the Oslo area who were due to receive a 2nd reminder to attend regular screening were randomly selected and invited to be part of the intervention group. Women in this group received one of two self-sampling devices, Evalyn Brush or Delphi Screener. To attend screening, women in the intervention group had the option of using the self-sampling device (self-sampling subgroup) or visiting their physician for a cervical smear. Self-sampled specimens were split and analyzed for the presence of high-risk (hr) HPV by the CLART® HPV2 test and the digene® Hybrid Capture (HC)2 test. The control group consisted of 2593 women who received a 2nd reminder letter according to the current guidelines of the NCCSP. The attendance rates were 33.4% in the intervention group and 23.2% in the control group, with similar attendance rates for both self-sampling devices. Women in the self-sampling subgroup responded favorably to both self-sampling devices and cited not remembering receiving a call for screening as the most dominant reason for previous non-attendance. Thirty-two of 34 (94.1%) hrHPV-positive women in the self-sampling subgroup attended follow-up. In conclusion, self-sampling increased attendance rates and was feasible and well received. This study lends further support to the proposal that self-sampling may be a valuable alternative for increasing cervical cancer screening coverage in Norway.

  18. Passive gas separator and accumulator device

    DOEpatents

    Choe, H.; Fallas, T.T.

    1994-08-02

    A separation device employing a gas separation filter and swirler vanes for separating gas from a gas-liquid mixture is provided. The cylindrical filter utilizes the principle that surface tension in the pores of the filter prevents gas bubbles from passing through. As a result, the gas collects in the interior region of the filter and coalesces to form larger bubbles in the center of the device. The device is particularly suited for use in microgravity conditions since the swirlers induce a centrifugal force which causes liquid to move from the inner region of the filter, pass the pores, and flow through the outlet of the device while the entrained gas is trapped by the filter. The device includes a cylindrical gas storage screen which is enclosed by the cylindrical gas separation filter. The screen has pores that are larger than those of the filters. The screen prevents larger bubbles that have been formed from reaching and interfering with the pores of the gas separation filter. The device is initially filled with a gas other than that which is to be separated. This technique results in separation of the gas even before gas bubbles are present in the mixture. Initially filling the device with the dissimilar gas and preventing the gas from escaping before operation can be accomplished by sealing the dissimilar gas in the inner region of the separation device with a ruptured disc which can be ruptured when the device is activated for use. 3 figs.

  19. Passive gas separator and accumulator device

    DOEpatents

    Choe, Hwang; Fallas, Thomas T.

    1994-01-01

    A separation device employing a gas separation filter and swirler vanes for separating gas from a gasliquid mixture is provided. The cylindrical filter utilizes the principle that surface tension in the pores of the filter prevents gas bubbles from passing through. As a result, the gas collects in the interior region of the filter and coalesces to form larger bubbles in the center of the device. The device is particularly suited for use in microgravity conditions since the swirlers induce a centrifugal force which causes liquid to move from the inner region of the filter, pass the pores, and flow through the outlet of the device while the entrained gas is trapped by the filter. The device includes a cylindrical gas storage screen which is enclosed by the cylindrical gas separation filter. The screen has pores that are larger than those of the filters. The screen prevents larger bubbles that have been formed from reaching and interfering with the pores of the gas separation filter. The device is initially filled with a gas other than that which is to be separated. This technique results in separation of the gas even before gas bubbles are present in the mixture. Initially filling the device with the dissimilar gas and preventing the gas from escaping before operation can be accomplished by sealing the dissimilar gas in the inner region of the separation device with a ruptured disc which can be ruptured when the device is activated for use.

  20. 46 CFR 28.110 - Life preservers or other personal flotation devices.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Life preservers or other personal flotation devices. 28.110 Section 28.110 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY UNINSPECTED VESSELS REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Requirements for All Vessels § 28.110 Life preservers or...

  1. 46 CFR 28.110 - Life preservers or other personal flotation devices.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Life preservers or other personal flotation devices. 28.110 Section 28.110 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY UNINSPECTED VESSELS REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Requirements for All Vessels § 28.110 Life preservers or...

  2. 46 CFR 28.110 - Life preservers or other personal flotation devices.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 1 2013-10-01 2013-10-01 false Life preservers or other personal flotation devices. 28.110 Section 28.110 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY UNINSPECTED VESSELS REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Requirements for All Vessels § 28.110 Life preservers or...

  3. 46 CFR 28.110 - Life preservers or other personal flotation devices.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 1 2012-10-01 2012-10-01 false Life preservers or other personal flotation devices. 28.110 Section 28.110 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY UNINSPECTED VESSELS REQUIREMENTS FOR COMMERCIAL FISHING INDUSTRY VESSELS Requirements for All Vessels § 28.110 Life preservers or...

  4. Subscale Ship Airwake Studies Using Novel Vortex Flow Devices with Smoke, Laser-Vapor-Screen and Particle Image Velocimetry

    NASA Technical Reports Server (NTRS)

    Lamar, John E.; Landman, Drew; Swift, Russell S.; Parikh, Paresh C.

    2007-01-01

    Ships produce vortices and air-wakes while either underway or stationary in a wind. These flow fields can be detrimental to the conduction of air operations in that they can adversely impact the air vehicles and flight crews. There are potential solutions to these problems for both frigates/destroyers and carriers through the use of novel vortex flow or flow control devices. This appendix highlights several devices which may have application and points out that traditional wind-tunnel testing using smoke, laser-vapor screen, and Particle Image Velocimetry can be useful in sorting out the effectiveness of different devices.

  5. 50 CFR 100.25 - Subsistence taking of fish, wildlife, and shellfish: general regulations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., Sitka black-tailed deer, elk, mountain goat, moose, musk ox, Dall sheep, wolf, and wolverine. Bow means..., wolf, or wolverine. Fyke net means a fixed, funneling (fyke) device used to entrap fish. Gear means any... wildlife as food for a dog or furbearer, or as bait, except as allowed for in § __.26, § __.27, or § __.28...

  6. 50 CFR 100.25 - Subsistence taking of fish, wildlife, and shellfish: general regulations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., Sitka black-tailed deer, elk, mountain goat, moose, musk ox, Dall sheep, wolf, and wolverine. Bow means..., wolf, or wolverine. Fyke net means a fixed, funneling (fyke) device used to entrap fish. Gear means any... wildlife as food for a dog or furbearer, or as bait, except as allowed for in § __.26, § __.27, or § __.28...

  7. 50 CFR 100.25 - Subsistence taking of fish, wildlife, and shellfish: general regulations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., Sitka black-tailed deer, elk, mountain goat, moose, musk ox, Dall sheep, wolf, and wolverine. Bow means..., wolf, or wolverine. Fyke net means a fixed, funneling (fyke) device used to entrap fish. Gear means any... wildlife as food for a dog or furbearer, or as bait, except as allowed for in § __.26, § __.27, or § __.28...

  8. Recruitment and retention of women in fishing communities in HIV prevention research.

    PubMed

    Ssetaala, Ali; Nakiyingi-Miiro, Jessica; Asiimwe, Stephen; Nanvubya, Annet; Mpendo, Juliet; Asiki, Gershim; Nielsen, Leslie; Kiwanuka, Noah; Seeley, Janet; Kamali, Anatoli; Kaleebu, Pontiano

    2015-01-01

    Women in fishing communities in Uganda are more at risk and have higher rates of HIV infection. Socio-cultural gender norms, limited access to health information and services, economic disempowerment, sexual abuse and their biological susceptibility make women more at risk of infection. There is need to design interventions that cater for women's vulnerability. We explore factors affecting recruitment and retention of women from fishing communities in HIV prevention research. An HIV incidence cohort screened 2074 volunteers (1057 men and 1017 women) aged 13-49 years from 5 fishing communities along Lake Victoria using demographic, medical history, risk behaviour assessment questionnaires.1000 HIV negative high risk volunteers were enrolled and followed every 6 months for 18 months. Factors associated with completion of study visits among women were analyzed using multivariable logistic regression. Women constituted 1,017(49%) of those screened, and 449(45%) of those enrolled with a median (IQR) age of 27 (22-33) years. Main reasons for non-enrolment were HIV infection (33.9%) and reported low risk behaviour (37.5%). A total of 382 (74%) women and 332 (69%) men completed all follow up visits. Older women (>24 yrs) and those unemployed, who had lived in the community for 5 years or more, were more likely to complete all study visits. Women had better retention rates than men at 18 months. Strategies for recruiting and retaining younger women and those who have stayed for less than 5 years need to be developed for improved retention of women in fishing communities in HIV prevention and research Programs.

  9. Protection Method of Biological Lightning Safety around Power Grid Based on Grounding Electrode Structure

    NASA Astrophysics Data System (ADS)

    Sixiang, Chen; Daopin, Chen; Ming, Zhang; Xiao, Huang; Jian, He; Zhijie, He

    2017-05-01

    Aimed at the actual situation of fish death in fish ponds near the power transmission line towers after the thunderstorm happened in Guangdong Province in China, this paper studied the influence of the ground current on fish in the pond. Firstly, This paper studied the current density of the fish without protection. On this basis, paper studied the horizontal pole with full-shielded, the vertical pole with half-shielded, the horizontal pole with extension three kinds of protective measures and effects. Finally an effective protection scheme was put forward according to the engineering practice. The results can provide some engineering guidance and quantitative basis for the design and modification of grounding devices when the tower is adjacent to the fish ponds in southern China.

  10. A Disposable Microfluidic Device with a Screen Printed Electrode for Mimicking Phase II Metabolism

    PubMed Central

    Vasiliadou, Rafaela; Nasr Esfahani, Mohammad Mehdi; Brown, Nathan J.; Welham, Kevin J.

    2016-01-01

    Human metabolism is investigated using several in vitro methods. However, the current methodologies are often expensive, tedious and complicated. Over the last decade, the combination of electrochemistry (EC) with mass spectrometry (MS) has a simpler and a cheaper alternative to mimic the human metabolism. This paper describes the development of a disposable microfluidic device with a screen-printed electrode (SPE) for monitoring phase II GSH reactions. The proposed chip has the potential to be used as a primary screening tool, thus complementing the current in vitro methods. PMID:27598162

  11. High-throughput behavioral screening method for detecting auditory response defects in zebrafish.

    PubMed

    Bang, Pascal I; Yelick, Pamela C; Malicki, Jarema J; Sewell, William F

    2002-08-30

    We have developed an automated, high-throughput behavioral screening method for detecting hearing defects in zebrafish. Our assay monitors a rapid escape reflex in response to a loud sound. With this approach, 36 adult zebrafish, restrained in visually isolated compartments, can be simultaneously assessed for responsiveness to near-field 400 Hz sinusoidal tone bursts. Automated, objective determinations of responses are achieved with a computer program that obtains images at precise times relative to the acoustic stimulus. Images taken with a CCD video camera before and after stimulus presentation are subtracted to reveal a response to the sound. Up to 108 fish can be screened per hour. Over 6500 fish were tested to validate the reliability of the assay. We found that 1% of these animals displayed hearing deficits. The phenotypes of non-responders were further assessed with radiological analysis for defects in the gross morphology of the auditory system. Nearly all of those showed abnormalities in conductive elements of the auditory system: the swim bladder or Weberian ossicles. Copyright 2002 Elsevier Science B.V.

  12. Occupancy models for monitoring marine fish: a bayesian hierarchical approach to model imperfect detection with a novel gear combination.

    PubMed

    Coggins, Lewis G; Bacheler, Nathan M; Gwinn, Daniel C

    2014-01-01

    Occupancy models using incidence data collected repeatedly at sites across the range of a population are increasingly employed to infer patterns and processes influencing population distribution and dynamics. While such work is common in terrestrial systems, fewer examples exist in marine applications. This disparity likely exists because the replicate samples required by these models to account for imperfect detection are often impractical to obtain when surveying aquatic organisms, particularly fishes. We employ simultaneous sampling using fish traps and novel underwater camera observations to generate the requisite replicate samples for occupancy models of red snapper, a reef fish species. Since the replicate samples are collected simultaneously by multiple sampling devices, many typical problems encountered when obtaining replicate observations are avoided. Our results suggest that augmenting traditional fish trap sampling with camera observations not only doubled the probability of detecting red snapper in reef habitats off the Southeast coast of the United States, but supplied the necessary observations to infer factors influencing population distribution and abundance while accounting for imperfect detection. We found that detection probabilities tended to be higher for camera traps than traditional fish traps. Furthermore, camera trap detections were influenced by the current direction and turbidity of the water, indicating that collecting data on these variables is important for future monitoring. These models indicate that the distribution and abundance of this species is more heavily influenced by latitude and depth than by micro-scale reef characteristics lending credence to previous characterizations of red snapper as a reef habitat generalist. This study demonstrates the utility of simultaneous sampling devices, including camera traps, in aquatic environments to inform occupancy models and account for imperfect detection when describing factors influencing fish population distribution and dynamics.

  13. Occupancy Models for Monitoring Marine Fish: A Bayesian Hierarchical Approach to Model Imperfect Detection with a Novel Gear Combination

    PubMed Central

    Coggins, Lewis G.; Bacheler, Nathan M.; Gwinn, Daniel C.

    2014-01-01

    Occupancy models using incidence data collected repeatedly at sites across the range of a population are increasingly employed to infer patterns and processes influencing population distribution and dynamics. While such work is common in terrestrial systems, fewer examples exist in marine applications. This disparity likely exists because the replicate samples required by these models to account for imperfect detection are often impractical to obtain when surveying aquatic organisms, particularly fishes. We employ simultaneous sampling using fish traps and novel underwater camera observations to generate the requisite replicate samples for occupancy models of red snapper, a reef fish species. Since the replicate samples are collected simultaneously by multiple sampling devices, many typical problems encountered when obtaining replicate observations are avoided. Our results suggest that augmenting traditional fish trap sampling with camera observations not only doubled the probability of detecting red snapper in reef habitats off the Southeast coast of the United States, but supplied the necessary observations to infer factors influencing population distribution and abundance while accounting for imperfect detection. We found that detection probabilities tended to be higher for camera traps than traditional fish traps. Furthermore, camera trap detections were influenced by the current direction and turbidity of the water, indicating that collecting data on these variables is important for future monitoring. These models indicate that the distribution and abundance of this species is more heavily influenced by latitude and depth than by micro-scale reef characteristics lending credence to previous characterizations of red snapper as a reef habitat generalist. This study demonstrates the utility of simultaneous sampling devices, including camera traps, in aquatic environments to inform occupancy models and account for imperfect detection when describing factors influencing fish population distribution and dynamics. PMID:25255325

  14. Cytotoxicity assays with fish cells as an alternative to the acute lethality test with fish.

    PubMed

    Segner, Helmut

    2004-10-01

    In ecotoxicology, in vitro assays with fish cells are currently applied for mechanistic studies, bioanalytical purposes and toxicity screening. This paper discusses the potential of cytotoxicity assays with fish cells to reduce, refine or replace acute lethality tests using fish. Basal cytotoxicity data obtained with fish cell lines or fish primary cell cultures show a reasonable to good correlation with lethality data from acute toxicity tests, with the exception of compounds that exert a specific mode of toxic action. Basal cytotoxicity data from fish cell lines also correlate well with cytotoxicity data from mammalian cell lines. However, both the piscine and mammalian in vitro assays are clearly less sensitive than the fish test. Therefore, in vivo LC50 values (concentrations of the test compounds that are lethal to 50% of the fish in the experiment within 96 hours) currently cannot be predicted from in vitro values. This in vitro-in vivo difference in sensitivity appears to be true for both fish cell lines and mammalian cell lines. Given the good in vitro-in vivo correlation in toxicity ranking, together with the clear-cut difference in sensitivity, the role of cytotoxicity assays in a tiered alternative testing strategy could be in priority setting in relation to toxic hazard and in the toxicity classification of chemicals and environmental samples.

  15. Genomic comparison of virulent and non-virulent Streptococcus agalactiae in fish.

    PubMed

    Delannoy, C M J; Zadoks, R N; Crumlish, M; Rodgers, D; Lainson, F A; Ferguson, H W; Turnbull, J; Fontaine, M C

    2016-01-01

    Streptococcus agalactiae infections in fish are predominantly caused by beta-haemolytic strains of clonal complex (CC) 7, notably its namesake sequence type (ST) 7, or by non-haemolytic strains of CC552, including the globally distributed ST260. In contrast, CC23, including its namesake ST23, has been associated with a wide homeothermic and poikilothermic host range, but never with fish. The aim of this study was to determine whether ST23 is virulent in fish and to identify genomic markers of fish adaptation of S. agalactiae. Intraperitoneal challenge of Nile tilapia, Oreochromis niloticus (Linnaeus), showed that ST260 is lethal at doses down to 10(2) cfu per fish, whereas ST23 does not cause disease at 10(7) cfu per fish. Comparison of the genome sequence of ST260 and ST23 with those of strains derived from fish, cattle and humans revealed the presence of genomic elements that are unique to subpopulations of S. agalactiae that have the ability to infect fish (CC7 and CC552). These loci occurred in clusters exhibiting typical signatures of mobile genetic elements. PCR-based screening of a collection of isolates from multiple host species confirmed the association of selected genes with fish-derived strains. Several fish-associated genes encode proteins that potentially provide fitness in the aquatic environment. © 2014 John Wiley & Sons Ltd.

  16. Variation in fish mercury concentrations in streams of the Adirondack region, New York: A simplified screening approach using chemical metrics

    USGS Publications Warehouse

    Burns, Douglas A.; Riva-Murray, Karen

    2018-01-01

    Simple screening approaches for the neurotoxicant methylmercury (MeHg) in aquatic ecosystems may be helpful in risk assessments of natural resources. We explored the development of such an approach in the Adirondack Mountains of New York, USA, a region with high levels of MeHg bioaccumulation. Thirty-six perennial streams broadly representative of 1st and 2nd order streams in the region were sampled during summer low flow and analyzed for several solutes and for Hg concentrations in fish. Several landscape and chemical metrics that are typically strongly related to MeHg concentrations in aquatic biota were explored for strength of association with fish Hg concentrations. Data analyses were based on site mean length-normalized and standardized Hg concentrations (assumed to be dominantly MeHg) in whole juvenile and adult Brook Trout Salvelinus fontinalis, Creek Chub Semotilus atromaculatus, Blacknose Dace Rhinichthys atratulus, and Central Mudminnow Umbra limi, as well as on multi-species z-scores. Surprisingly, none of the landscape metrics was related significantly to regional variation in fish Hg concentrations or to z-scores across the study streams. In contrast, several chemical metrics including dissolved organic carbon (DOC) concentrations, sulfate concentrations (SO42−), pH, ultra-violet absorbance (UV254), and specific ultra-violet absorbance were significantly related to regional variation in fish Hg concentrations. A cluster analysis based on DOC, SO42−, and pH identified three distinct groups of streams: (1) high DOC, acidic streams, (2) moderate DOC, slightly acidic streams, and (3) low DOC circum-neutral streams with relatively high SO42−. Preliminary analysis indicated no significant difference in fish Hg z-scores between the moderate and high DOC groups, so these were combined for further analysis. The resulting two groups showed strong differences (p < 0.001) in DOC and SO42−concentrations as well as in pH and UV254 values. Median fish z-scores were significantly higher (p = 0.002) in the group of streams with higher DOC and UV254 and lower pH and SO42−. Screening values of DOC >6.9 mg/L, SO42− <2.8 mg/L, pH <6.6, and UV254>0.31 cm−1 were tested as thresholds to identify Adirondack stream sites likely to have higher fish Hg concentrations. By applying a combined threshold of exceedance for either pH or UV254, sites with fish Hg concentrations that exceeded a wildlife guideline of 100 ng/g were correctly identified about 75% of the time among the 36 study streams. An estimate of Hg risk applied to a data set of 391 streams based on DOC concentrations showed that about 28% were likely to pose high risk to wildlife; most of these streams were located in the western Adirondacks.

  17. Marine steroids as potential anticancer drug candidates: In silico investigation in search of inhibitors of Bcl-2 and CDK-4/Cyclin D1.

    PubMed

    Saikia, Surovi; Kolita, Bhaskor; Dutta, Partha P; Dutta, Deep J; Neipihoi; Nath, Shyamalendu; Bordoloi, Manobjyoti; Quan, Pham Minh; Thuy, Tran Thu; Phuong, Doan Lan; Long, Pham Quoc

    2015-10-01

    Star fishes (Asteroidea) are rich in polar steroids with diverse structural characteristics. The structural modifications of star fish steroids occur at 3β, 4β, 5α, 6α (or β), 7α (or β), 8, 15α (or β) and 16β positions of the steroidal nucleus and in the side chain. Widely found polar steroids in starfishes include polyhydroxysteroids, steroidal sulfates, glycosides, steroid oligoglycosides etc. Bioactivity of these steroids is less studied; only a few reports like antibacterial, cytotoxic activity etc. are available. In continuation of our search for bioactive molecules from natural sources, we undertook in silico screening of steroids from star fishes against Bcl-2 and CDK-4/Cyclin D1 - two important targets of progression and proliferation of cancer cells. We have screened 182 natural steroids from star fishes occurring in different parts of the world and their 282 soft-derivatives by in silico methods. Their physico-chemical properties, drug-likeliness, binding potential with the selected targets, ADMET (absorption, distribution, metabolism, toxicity) were predicted. Further, the results were compared with those of existing steroidal and non steroidal drugs and inhibitors of Bcl-2 and CDK-4/Cyclin D1. The results are promising and unveil that some of these steroids can be potent leads for cancer treatments. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Evaluation of ALK gene rearrangement in central nervous system metastases of non-small-cell lung cancer using two-step RT-PCR technique.

    PubMed

    Nicoś, M; Krawczyk, P; Wojas-Krawczyk, K; Bożyk, A; Jarosz, B; Sawicki, M; Trojanowski, T; Milanowski, J

    2017-12-01

    RT-PCR technique has showed a promising value as pre-screening method for detection of mRNA containing abnormal ALK sequences, but its sensitivity and specificity is still discussable. Previously, we determined the incidence of ALK rearrangement in CNS metastases of NSCLC using IHC and FISH methods. We evaluated ALK gene rearrangement using two-step RT-PCR method with EML4-ALK Fusion Gene Detection Kit (Entrogen, USA). The studied group included 145 patients (45 females, 100 males) with CNS metastases of NSCLC and was heterogeneous in terms of histology and smoking status. 21% of CNS metastases of NSCLC (30/145) showed presence of mRNA containing abnormal ALK sequences. FISH and IHC tests confirmed the presence of ALK gene rearrangement and expression of ALK abnormal protein in seven patients with positive result of RT-PCR analysis (4.8% of all patients, 20% of RT-PCR positive patients). RT-PCR method compared to FISH analysis achieved 100% of sensitivity and only 82.7% of specificity. IHC method compared to FISH method indicated 100% of sensitivity and 97.8% of specificity. In comparison to IHC, RT-PCR showed identical sensitivity with high number of false positive results. Utility of RT-PCR technique in screening of ALK abnormalities and in qualification patients for molecularly targeted therapies needs further validation.

  19. Noise screen for attitude control system

    NASA Technical Reports Server (NTRS)

    Rodden, John J. (Inventor); Stevens, Homer D. (Inventor); Hong, David P. (Inventor); Hirschberg, Philip C. (Inventor)

    2002-01-01

    An attitude control system comprising a controller and a noise screen device coupled to the controller. The controller is adapted to control an attitude of a vehicle carrying an actuator system that is adapted to pulse in metered bursts in order to generate a control torque to control the attitude of the vehicle in response to a control pulse. The noise screen device is adapted to generate a noise screen signal in response to the control pulse that is generated when an input attitude error signal exceeds a predetermined deadband attitude level. The noise screen signal comprises a decaying offset signal that when combined with the attitude error input signal results in a net attitude error input signal away from the predetermined deadband level to reduce further control pulse generation.

  20. Fish scale terrace GaInN/GaN light-emitting diodes with enhanced light extraction

    NASA Astrophysics Data System (ADS)

    Stark, Christoph J. M.; Detchprohm, Theeradetch; Zhao, Liang; Paskova, Tanya; Preble, Edward A.; Wetzel, Christian

    2012-12-01

    Non-planar GaInN/GaN light-emitting diodes were epitaxially grown to exhibit steps for enhanced light emission. By means of a large off-cut of the epitaxial growth plane from the c-plane (0.06° to 2.24°), surface morphologies of steps and inclined terraces that resemble fish scale patterns could controllably be achieved. These patterns penetrate the active region without deteriorating the electrical device performance. We find conditions leading to a large increase in light-output power over the virtually on-axis device and over planar sapphire references. The process is found suitable to enhance light extraction even without post-growth processing.

  1. Fatal Falls Overboard in Commercial Fishing - United States, 2000-2016.

    PubMed

    Case, Samantha L; Lincoln, Jennifer M; Lucas, Devin L

    2018-04-27

    Commercial fishing is one of the most dangerous jobs in the United States, with a 2016 work-related fatality rate (86.0 deaths per 100,000 full-time equivalent workers) 23 times higher than that for all U.S. workers (3.6) (1). Sinking vessels cause the most fatalities in the industry; however, falling from a fishing vessel is a serious hazard responsible for the second highest number of commercial fishing-associated fatalities (2,3). CDC's National Institute for Occupational Safety and Health (NIOSH) analyzed data on unintentional fatal falls overboard in the U.S. commercial fishing industry to identify gaps in the use of primary, secondary, and tertiary prevention strategies. During 2000-2016, a total of 204 commercial fishermen died after unintentionally falling overboard. The majority of falls (121; 59.3%) were not witnessed, and 108 (89.3%) of these victims were not found. Among 83 witnessed falls overboard, 56 rescue attempts were made; 22 victims were recovered but were not successfully resuscitated. The circumstances, rescue attempts, and limited use of lifesaving and recovery equipment indicate that efforts to reduce these preventable fatalities are needed during pre-event, event, and post-event sequences of falls overboard. Vessel owners could consider strategies to prevent future fatalities, including lifeline tethers, line management, personal flotation devices (PFDs), man-overboard alarms, recovery devices, and rescue training.

  2. Screening for Physical Problems in Classrooms for Severely Handicapped Students.

    ERIC Educational Resources Information Center

    Dever, Richard; Knapczyk, Dennis

    1980-01-01

    The authors present a screening device with which teachers of severely handicapped students may detect the presence of a physical problem. The screening approach covers vision, auditory problems, seizures, orthopedic problems, and pain. (CL)

  3. Bis(4-chlorophenyl) sulfone (BCPS) in Swedish marine and fresh water wildlife-a screening study.

    PubMed

    Norström, Karin; Olsson, Anders; Olsson, Mats; Bergman, Ake

    2004-07-01

    Bis(4-chlorophenyl) sulfone (BCPS) is a high production volume chemical (HPVC) applied in thermostable polymers. BCPS has been detected as an environmental contaminant both in Europe and in North America but it is still not a commonly studied pollutant. In this study, three Baltic Sea fish species; herring (Clupea harengus), salmon (Salmo salar) and perch (Perca fluviatilis) from the Swedish coast, and one inland fish species, arctic char (Salvelinus alpinus), were analysed to screen for the occurrence and distribution of BCPS. Salmon and arctic char, were sampled in the early 1970s as well as the late 1990s. Fish eating grey seal (Halichoerus gryphus) and guillemot (Uria aalge) from the Baltic Sea were included to screen for whether BCPS biomagnify or not. The representativeness of the analysed samples for studying bioaccumulation of environmental pollutants was compared through analysis of two well known persistent and bioaccumulating compounds, 2,2',4,4',5,5'-hexachlorobiphenyl (CB-153), and 4,4'-DDE. Pooled muscle and blubber samples based on 4-10 individuals were used for analysis, as well as individual samples of grey seal blubber. 2,4,4'-Trichlorodiphenyl sulfone, was synthesised and applied as an internal standard. BCPS was detected in all marine samples but in only one of the fresh water fish samples. The highest BCPS concentrations detected, 1600 and 1900 ng/g lipid weighet (l.w.), were found in muscle from Baltic guillemot. The results indicate that BCPS is bioaccumulated in both grey seal and guillemot, and that the guillemot has higher concentrations of BCPS than the grey seal (50-500 ng/g l.w.). The concentrations found in different species of fish from the Baltic Sea ranged between 15-37 ng/g l.w. and lower concentrations were found in freshwater species (n.d.-1.8 ng/g l.w.). The present study shows that BCPS is found in all investigated species of wildlife but, in most species, still at low concentrations. However, the guillemot has levels in the low ppm range indicating a considerable biomagnification of BCPS in this species.

  4. Evaluation of ALK Rearrangement in Chinese Non-Small Cell Lung Cancer Using FISH, Immunohistochemistry, and Real-Time Quantitative RT- PCR on Paraffin-Embedded Tissues

    PubMed Central

    Zhang, Yun-Gang; Jin, Mu-Lan; Li, Li; Zhao, Hong-Ying; Zeng, Xuan; Jiang, Lei; Wei, Ping; Diao, Xiao-Li; Li, Xue; Cao, Qing; Tian, Xin-Xia

    2013-01-01

    Patients with ALK gene rearrangements often manifest dramatic responses to crizotinib, an ALK inhibitor. Accurate identification of patients with ALK-positive non-small cell lung cancer (NSCLC) is essential for the clinical application of ALK-targeted therapy. However, assessing EML4-ALK rearrangement in NSCLC remains challenging in routine pathology practice. The aim of this study was to compare the diagnostic accuracy of FISH, immunohistochemistry (IHC), and real-time quantitative RT-PCR (QPCR) methodologies for detection of EML4-ALK rearrangement in NSCLC and to appraise immunohistochemistry as a pre-screening tool. In this study, a total of 473 paraffin-embedded NSCLC samples from surgical resections and biopsies were analyzed by IHC with ALK antibody. ALK rearrangement was further confirmed by FISH and QPCR. ALK protein expression was detected in twenty patients (20/473, 4.2%). Of the 20 ALK-positive cases by IHC, 15 cases were further confirmed as ALK rearrangement by FISH, and 5 cases were not interpretable. Also, we evaluated 13 out of the 20 IHC-positive tissues by QPCR in additional to FISH, and found that 9 cases were positive and 2 cases were equivocal, whereas 2 cases were negative although they were positive by both IHC and FISH. The ALK status was concordant in 5 out of 8 cases that were interpretable by three methods. Additionally, none of the 110 IHC-negative cases with adenocarcinoma histology showed ALK rearrangements by FISH. Histologically, almost all the ALK-rearranged cases were adenocarcinoma, except that one case was sarcomatoid carcinoma. A solid signet-ring cell pattern or mucinous cribriform pattern was presented at least focally in all ALK-positive tumors. In conclusion, our findings suggested that ALK rearrangement was associated with ALK protein expression. The conventional IHC assay is a valuable tool for the pre-screening of patients with ALK rearrangement in clinical practice and a combination of FISH and QPCR is required for further confirmation. PMID:23741400

  5. PGS-FISH in reproductive medicine and perspective directions for improvement: a systematic review.

    PubMed

    Zamora, Sandra; Clavero, Ana; Gonzalvo, M Carmen; de Dios Luna Del Castillo, Juan; Roldán-Nofuentes, Jose Antonio; Mozas, Juan; Castilla, Jose Antonio

    2011-08-01

    Embryo selection can be carried out via morphological criteria or by using genetic studies based on Preimplantation Genetic Screening. In the present study, we evaluate the clinical validity of Preimplantation Genetic Screening with fluorescence in situ hybridization (PGS-FISH) compared with morphological embryo criteria. A systematic review was made of the bibliography, with the following goals: firstly, to determine the prevalence of embryo chromosome alteration in clinical situations in which the PGS-FISH technique has been used; secondly, to calculate the statistics of diagnostic efficiency (negative Likelihood Ratio), using 2 × 2 tables, derived from PGS-FISH. The results obtained were compared with those obtained from embryo morphology. We calculated the probability of transferring at least one chromosome-normal embryo when it was selected using either morphological criteria or PGS-FISH, and considered what diagnostic performance should be expected of an embryo selection test with respect to achieving greater clinical validity than that obtained from embryo morphology. After an embryo morphology selection that produced a negative result (normal morphology), the likelihood of embryo aneuploidies was found to range from a pre-test value of 65% (prevalence of embryo chromosome alteration registered in all the study groups) to a post-test value of 55% (Confidence interval: 50-61), while after PGS-FISH with a negative result (euploid), the post-test probability was 42% (Confidence interval: 35-49) (p < 0.05). The probability of transferring at least one euploid embryo was the same whether 3 embryos were selected according to morphological criteria or whether 2, selected by PGS-FISH, were transferred. Any embryo selection test, if it is to provide greater clinical validity than embryo morphology, must present a LR-value of 0.40 (Confidence interval: 0.32-0.51) in single embryo transfer, and 0.06 (CI: 0.05-0.07) in double embryo transfer. With currently available technology, and taking into account the number of embryos to be transferred, the clinical validity of PGS-FISH, although superior to that of morphological criteria, does not appear to be clinically relevant.

  6. Validation of the custo screen pediatric blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Beime, Beate; Deutsch, Cornelia; Krüger, Ralf; Wolf, Andreas; Müller, Peter; Hammel, Gertrud; Bramlage, Peter

    2017-05-01

    The purpose of the study was to validate the ambulatory blood pressure monitoring (ABPM) device custo screen pediatric in children aged 3 to 12 years according to the International Protocol of the European Society of Hypertension (ESH-IP revision 2010). Thirty-three children were included and systolic and diastolic blood pressure measurements were performed according to the ESH-IP. The protocol was modified for children considering data from the German Health Interview and Examination Survey for Children and Adolescents (KIGGS). The custo screen pediatric met all the requirements of the ESH-IP. The mean difference between the test device and the reference was -1.4 ± 3.0 mmHg for systolic blood pressure (SBP) and -0.7 ± 3.2 mmHg for diastolic blood pressure (DBP). For SBP and DBP, all 99 measurements were within the absolute difference of 10 mmHg between the test device and the reference. As to part 2 of the protocol, for DBP in all subjects, two out of three measurements were within 5 mmHg between the device and the standard, whereas for SBP in 32 of 33 subjects, two out of three measurements were within this range. The custo screen pediatric met all criteria of the ESH-IP review 2010, modified for children from 3 to about 12 years, and can be recommended for ABPM in children. What is Known: • Validation of blood pressure measuring devices is essential to provide patients with an accurate blood pressure measuring device. • The majority of devices has not been validated in children. What is New: • Prior to the present validation, study protocol adjustments of ESH-IP review 2010 for children were defined according to German Health Interview and Examination Survey for Children and Adolescents 2013 (KIGGS). • The custo screen pediatric test device met all criteria of ESH-IP revision 2010, modified for children, and can be recommended for ABPM in children aged 3 to about 12 years.

  7. Effect of Pile-Driving Sounds on the Survival of Larval Fish.

    PubMed

    Bolle, Loes J; de Jong, Christ A F; Bierman, Stijn M; van Beek, Pieter J G; Wessels, Peter W; Blom, Ewout; van Damme, Cindy J G; Winter, Hendrik V; Dekeling, René P A

    2016-01-01

    Concern exists about the potential effects of pile-driving sounds on fish, but evidence is limited, especially for fish larvae. A device was developed to expose larvae to accurately reproduced pile-driving sounds. Controlled exposure experiments were carried out to examine the lethal effects in common sole larvae. No significant effects were observed at zero-to-peak pressure levels up to 210 dB re 1 μPa(2) and cumulative sound exposure levels up to 206 dB re 1 μPa(2)·s, which is well above the US interim criteria for nonauditory tissue damage in fish. Experiments are presently being carried out for European sea bass and herring larvae.

  8. Reagent and labor cost optimization through automation of fluorescence in situ hybridization (FISH) with the VP 2000: an Italian case study.

    PubMed

    Zanatta, Lucia; Valori, Laura; Cappelletto, Eleonora; Pozzebon, Maria Elena; Pavan, Elisabetta; Dei Tos, Angelo Paolo; Merkle, Dennis

    2015-02-01

    In the modern molecular diagnostic laboratory, cost considerations are of paramount importance. Automation of complex molecular assays not only allows a laboratory to accommodate higher test volumes and throughput but also has a considerable impact on the cost of testing from the perspective of reagent costs, as well as hands-on time for skilled laboratory personnel. The following study tracked the cost of labor (hands-on time) and reagents for fluorescence in situ hybridization (FISH) testing in a routine, high-volume pathology and cytogenetics laboratory in Treviso, Italy, over a 2-y period (2011-2013). The laboratory automated FISH testing with the VP 2000 Processor, a deparaffinization, pretreatment, and special staining instrument produced by Abbott Molecular, and compared hands-on time and reagent costs to manual FISH testing. The results indicated significant cost and time saving when automating FISH with VP 2000 when more than six FISH tests were run per week. At 12 FISH assays per week, an approximate total cost reduction of 55% was observed. When running 46 FISH specimens per week, the cost saving increased to 89% versus manual testing. The results demonstrate that the VP 2000 processor can significantly reduce the cost of FISH testing in diagnostic laboratories. © 2014 Society for Laboratory Automation and Screening.

  9. MYC and MYCN amplification can be reliably assessed by aCGH in medulloblastoma.

    PubMed

    Bourdeaut, Franck; Grison, Camille; Maurage, Claude-Alain; Laquerriere, Annie; Vasiljevic, Alexandre; Delisle, Marie-Bernadette; Michalak, Sophie; Figarella-Branger, Dominique; Doz, François; Richer, Wilfrid; Pierron, Gaelle; Miquel, Catherine; Delattre, Olivier; Couturier, Jérôme

    2013-04-01

    As prognostic factors, MYC and MYCN amplifications are routinely assessed in medulloblastomas. Fluorescence in situ hybridization (FISH) is currently considered as the technique of reference. Recently, array comparative genomic hybridization (aCGH) has been developed as an alternative technique to evaluate genomic abnormalities in other tumor types; however, this technique has not been widely adopted as a replacement for FISH in medulloblastoma. In this study, 34 tumors were screened by both FISH and aCGH. In all cases showing amplification by FISH, aCGH also unambiguously revealed the abnormality. The aCGH technique was also performed on tumors showing no amplification by FISH, and the absence of amplification was confirmed in all cases. Interestingly, one tumor showed a subclonal MYC amplification by FISH. This subclonal amplification was observed in approximately 20% of tumor cells and was clearly evident on aCGH. In conclusion, our analysis confirms that aCGH is as safe as FISH for the detection of MYC/MYCN gene amplification. Given its cost efficiency in comparison to two FISH tests and the global genomic information additionally provided by an aCGH experiment, this reproducible technique can be safely retained as an alternative to FISH for routine investigation of medulloblastoma. Copyright © 2013 Elsevier Inc. All rights reserved.

  10. Prediction of Phase Behavior of Spray-Dried Amorphous Solid Dispersions: Assessment of Thermodynamic Models, Standard Screening Methods and a Novel Atomization Screening Device with Regard to Prediction Accuracy

    PubMed Central

    Chavez, Pierre-François; Meeus, Joke; Robin, Florent; Schubert, Martin Alexander; Somville, Pascal

    2018-01-01

    The evaluation of drug–polymer miscibility in the early phase of drug development is essential to ensure successful amorphous solid dispersion (ASD) manufacturing. This work investigates the comparison of thermodynamic models, conventional experimental screening methods (solvent casting, quench cooling), and a novel atomization screening device based on their ability to predict drug–polymer miscibility, solid state properties (Tg value and width), and adequate polymer selection during the development of spray-dried amorphous solid dispersions (SDASDs). Binary ASDs of four drugs and seven polymers were produced at 20:80, 40:60, 60:40, and 80:20 (w/w). Samples were systematically analyzed using modulated differential scanning calorimetry (mDSC) and X-ray powder diffraction (XRPD). Principal component analysis (PCA) was used to qualitatively assess the predictability of screening methods with regards to SDASD development. Poor correlation was found between theoretical models and experimentally-obtained results. Additionally, the limited ability of usual screening methods to predict the miscibility of SDASDs did not guarantee the appropriate selection of lead excipient for the manufacturing of robust SDASDs. Contrary to standard approaches, our novel screening device allowed the selection of optimal polymer and drug loading and established insight into the final properties and performance of SDASDs at an early stage, therefore enabling the optimization of the scaled-up late-stage development. PMID:29518936

  11. Press touch code: A finger press based screen size independent authentication scheme for smart devices.

    PubMed

    Ranak, M S A Noman; Azad, Saiful; Nor, Nur Nadiah Hanim Binti Mohd; Zamli, Kamal Z

    2017-01-01

    Due to recent advancements and appealing applications, the purchase rate of smart devices is increasing at a higher rate. Parallely, the security related threats and attacks are also increasing at a greater ratio on these devices. As a result, a considerable number of attacks have been noted in the recent past. To resist these attacks, many password-based authentication schemes are proposed. However, most of these schemes are not screen size independent; whereas, smart devices come in different sizes. Specifically, they are not suitable for miniature smart devices due to the small screen size and/or lack of full sized keyboards. In this paper, we propose a new screen size independent password-based authentication scheme, which also offers an affordable defense against shoulder surfing, brute force, and smudge attacks. In the proposed scheme, the Press Touch (PT)-a.k.a., Force Touch in Apple's MacBook, Apple Watch, ZTE's Axon 7 phone; 3D Touch in iPhone 6 and 7; and so on-is transformed into a new type of code, named Press Touch Code (PTC). We design and implement three variants of it, namely mono-PTC, multi-PTC, and multi-PTC with Grid, on the Android Operating System. An in-lab experiment and a comprehensive survey have been conducted on 105 participants to demonstrate the effectiveness of the proposed scheme.

  12. Press touch code: A finger press based screen size independent authentication scheme for smart devices

    PubMed Central

    Ranak, M. S. A. Noman; Nor, Nur Nadiah Hanim Binti Mohd; Zamli, Kamal Z.

    2017-01-01

    Due to recent advancements and appealing applications, the purchase rate of smart devices is increasing at a higher rate. Parallely, the security related threats and attacks are also increasing at a greater ratio on these devices. As a result, a considerable number of attacks have been noted in the recent past. To resist these attacks, many password-based authentication schemes are proposed. However, most of these schemes are not screen size independent; whereas, smart devices come in different sizes. Specifically, they are not suitable for miniature smart devices due to the small screen size and/or lack of full sized keyboards. In this paper, we propose a new screen size independent password-based authentication scheme, which also offers an affordable defense against shoulder surfing, brute force, and smudge attacks. In the proposed scheme, the Press Touch (PT)—a.k.a., Force Touch in Apple’s MacBook, Apple Watch, ZTE’s Axon 7 phone; 3D Touch in iPhone 6 and 7; and so on—is transformed into a new type of code, named Press Touch Code (PTC). We design and implement three variants of it, namely mono-PTC, multi-PTC, and multi-PTC with Grid, on the Android Operating System. An in-lab experiment and a comprehensive survey have been conducted on 105 participants to demonstrate the effectiveness of the proposed scheme. PMID:29084262

  13. Optimization of Fish Protection System to Increase Technosphere Safety

    NASA Astrophysics Data System (ADS)

    Khetsuriani, E. D.; Fesenko, L. N.; Larin, D. S.

    2017-11-01

    The article is concerned with field study data. Drawing upon prior information and considering structural features of fish protection devices, we decided to conduct experimental research while changing three parameters: process pressure PCT, stream velocity Vp and washer nozzle inclination angle αc. The variability intervals of examined factors are shown in the Table 1. The conicity angle was assumed as a constant one. The box design B3 was chosen as a baseline being close to D-optimal designs in its statistical characteristics. The number of device rotations and its fish fry protection efficiency were accepted as the output functions of optimization. The numerical values of regression coefficients of quadratic equations describing the behavior of optimization functions Y1 and Y2 and their formulaic errors were calculated upon the test results in accordance with the planning matrix. The adequacy or inadequacy of the obtained quadratic regression model is judged via checking the condition whether Fexp ≤ Ftheor.

  14. Analysis and Evaluation of Parameters Determining Maximum Efficiency of Fish Protection

    NASA Astrophysics Data System (ADS)

    Khetsuriani, E. D.; Kostyukov, V. P.; Khetsuriani, T. E.

    2017-11-01

    The article is concerned with experimental research findings. The efficiency of fish fry protection from entering water inlets is the main criterion of any fish protection facility or device. The research was aimed to determine an adequate mathematical model E = f(PCT, Vp, α), where PCT, Vp and α are controlled factors influencing the process of fish fry protection. The result of the processing of experimental data was an adequate regression model. We determined the maximum of fish protection Emax=94,21 and the minimum of optimization function Emin=44,41. As a result of the statistical processing of experimental data we obtained adequate dependences for determining an optimal rotational speed of tip and fish protection efficiency. The analysis of fish protection efficiency dependence E% = f(PCT, Vp, α) allowed the authors to recommend the following optimized operating modes for it: the maximum fish protection efficiency is achieved at the process pressure PCT=3 atm, stream velocity Vp=0,42 m/s and nozzle inclination angle α=47°49’. The stream velocity Vp has the most critical influence on fish protection efficiency. The maximum efficiency of fish protection is obtained at the tip rotational speed of 70.92 rpm.

  15. Mercury exposure and source tracking in distinct marine-caged fish farm in southern China.

    PubMed

    Xu, Xiaoyu; Wang, Wen-Xiong

    2017-01-01

    Coasts of South China have experienced an unprecedented growth in its marine-caged fish industry. We analyzed mercury concentrations and stable mercury isotope ratios in fourteen fish species from two cage-cultured farms in Southern China. Total mercury concentrations of all species were lower than the human health screening values, but the human exposures through consumption of several carnivorous fish exceeded the USEPA's reference dose. Isotopic compositions in the sediment (δ 202 Hg: -1.45‰ to -1.23‰; Δ 199 Hg: -0.04‰ to -0.01‰) suggested that mercury in these farms were from coal combustion and industrial inputs. Commercial food pellets and fresh fish viscera provided the major sources of methylmercury to the farmed fish and dominated their mercury isotopic signatures. Non-carnivorous fish presented lower δ 202 Hg and Δ 199 Hg values than the carnivorous fish. Using a mixing model, we demonstrated that the majority of mercury in non-carnivorous species came from pellets and in carnivorous fish came from combined diets of pellets and viscera. Meanwhile, methylmercury concentrations and % methylmercury in the fish were positively correlated with δ 202 Hg values but not with Δ 199 Hg values, mainly because fish eating similar feeds maintained similar Δ 199 Hg values. Environmental influences of cage farming such as fish feces and uneaten viscera that continuously provide organic mercury to the environments need to be considered. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. 50 CFR 100.25 - Subsistence taking of fish, wildlife, and shellfish: general regulations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., Sitka black-tailed deer, elk, mountain goat, moose, musk ox, Dall sheep, wolf, and wolverine. Bow means..., wolf, or wolverine. Fyke net means a fixed, funneling (fyke) device used to entrap fish. Gear means any... wildlife as food for a dog or furbearer, or as bait, except as allowed for in § 100.26, § 100.27, or § 100...

  17. 50 CFR 100.25 - Subsistence taking of fish, wildlife, and shellfish: general regulations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., Sitka black-tailed deer, elk, mountain goat, moose, musk ox, Dall sheep, wolf, and wolverine. Bow means..., wolf, or wolverine. Fyke net means a fixed, funneling (fyke) device used to entrap fish. Gear means any... wildlife as food for a dog or furbearer, or as bait, except as allowed for in § 100.26, § 100.27, or § 100...

  18. Microfluidic devices for the controlled manipulation of small volumes

    DOEpatents

    Ramsey, J Michael [Knoxville, TN; Jacobson, Stephen C [Knoxville, TN

    2003-02-25

    A method for conducting a broad range of biochemical analyses or manipulations on a series of nano- to subnanoliter reaction volumes and an apparatus for carrying out the same are disclosed. The method and apparatus are implemented on a fluidic microchip to provide high serial throughput. The method and device of the invention also lend themselves to multiple parallel analyses and manipulation to provide greater throughput for the generation of biochemical information. In particular, the disclosed device is a microfabricated channel device that can manipulate nanoliter or subnanoliter biochemical reaction volumes in a controlled manner to produce results at rates of 1 to 10 Hz per channel. The individual reaction volumes are manipulated in serial fashion analogous to a digital shift register. The method and apparatus according to this invention have application to such problems as screening molecular or cellular targets using single beads from split-synthesis combinatorial libraries, screening single cells for RNA or protein expression, genetic diagnostic screening at the single cell level, or performing single cell signal transduction studies.

  19. GSM Web-Based Centralized Remote Wireless Automatic Controlling and Monitoring of Aquafeeder

    NASA Astrophysics Data System (ADS)

    Wong, C. L.; Idris, A.; Hasan, Z.

    2016-03-01

    This project is about producing a prototype to feed fishes at fish ponds of remote location with the use of GSM mobile phone. An automatic fish feeder is an electric device that has been designed to give out the right amount of pellets at the designed time. In this project, the automatic feeder designed consists of photovoltaic solar cells that are used to generate electricity and storing it into batteries. Solar charge controllers can be used to determine the rate of which current is drawn and added from the batteries. GSM cellular communication is used to allow user to control from a distance. Commands or instructions are sent to the operating system which in return runs the servomotor and blower by blowing certain amount of fish pallets into the pond to feed the fishes. The duration of the feeding processes is fixed by the user, hence the amount of fish food pallets released are precisely the same for each time. This technology is especially useful for fish farmers where they can remotely feed their fishes.

  20. Benthic Resources Assessment Technique Evaluation of Disposal Sites in Puget Sound and Adjacent Waters,

    DTIC Science & Technology

    1986-12-01

    of potential impacts to demersal fish feeding habitat. sites. 2. One aspect of benthic habitat quality is the relative amount of trophic support that...a given benthic habitat provides demersal bottom- feeding fishes. Analytical procedures have been developed at the U.S. Army Engineer Waterways...suspend the larger material and to allow fine sands, silts and clays to pass through the screens. Residual material was 2 I! Ii placeL a cloth bags that

  1. Detection of orthopaedic foot and ankle implants by security screening devices.

    PubMed

    Bluman, Eric M; Tankson, Cedric; Myerson, Mark S; Jeng, Clifford L

    2006-12-01

    A common question asked by patients contemplating foot and ankle surgery is whether the implants used will set off security screening devices in airports and elsewhere. Detectability of specific implants may require the orthopaedic surgeon to provide attestation regarding their presence in patients undergoing implantation of these devices. Only two studies have been published since security measures became more stringent in the post-9/11 era. None of these studies specifically focused on the large numbers of orthopaedic foot and ankle implants in use today. This study establishes empiric data on the detectability by security screening devices of some currently used foot and ankle implants. A list of foot and ankle procedures was compiled, including procedures frequently used by general orthopaedists as well as those usually performed only by foot and ankle specialists. Implants tested included those used for open reduction and internal fixation, joint fusion, joint arthroplasty, osteotomies, arthroreisis, and internal bone stimulation. A test subject walked through a gate-type security device and was subsequently screened using a wand-type detection device while wearing each construct grouping. The screening was repeated with the implants placed within uncooked steak to simulate subcutaneous and submuscular implantation. None of the implants were detected by the gate-type security device. Specific implants that triggered the wand-type detection device regardless of coverage with the meat were total ankle prostheses, implantable bone stimulators, large metatarsophalangeal hemiarthroplasty, large arthroreisis plugs, medial distal tibial locking construct, supramalleolar osteotomy fixation, stainless steel bimalleolar ankle fracture fixation, calcaneal fracture plate and screw constructs, large fragment blade plate constructs, intramedullary tibiotalocalcaneal fusion constructs, and screw fixation for calcaneal osteotomies, ankle arthrodeses, triple arthrodeses, and stainless steel first metatarsophalangeal joint arthrodeses. The placement of implants in meat prevented the detectability of only the stainless steel Jones fracture implant (stainless steel 6.5-mm cannulated screw) and the stainless steel midfoot fusion construct (four stainless steel 4.0-mm cannulated screws). These data may help the orthopaedic surgeon in counseling patients as to the detectability of some orthopaedic foot and ankle implants in use today. Specific constructs for which documentation may need to be provided to the patient are identified. As security standards evolve and the environments in which they are practiced change, empiric testing of many of these devices may need to be repeated.

  2. The Use of the Miller Analogies Test as a Screening Device for Mexican-American Graduate Students.

    ERIC Educational Resources Information Center

    Duling, John A.

    The determination of whether or not the Miller Analogies Test (MAT) is a valid screening device to use with a culturally diverse populace was examined. The study was conducted at New Mexico State University (NMSU) using 2 sample groups. Sample A consisted of 560 Anglos and 101 Mexican Americans tested by the NMSU Counseling Center during a 2-year…

  3. 49 CFR 40.263 - What happens when an employee is unable to provide a sufficient amount of saliva for an alcohol...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... sufficient amount of saliva for an alcohol screening test? (a) As the STT, you must take the following steps if an employee is unable to provide sufficient saliva to complete a test on a saliva screening device (e.g., the employee does not provide sufficient saliva to activate the device). (1) You must conduct...

  4. Velocity Vector Field Visualization of Flow in Liquid Acquisition Device Channel

    NASA Technical Reports Server (NTRS)

    McQuillen, John B.; Chao, David F.; Hall, Nancy R.; Zhang, Nengli

    2012-01-01

    A capillary flow liquid acquisition device (LAD) for cryogenic propellants has been developed and tested in NASA Glenn Research Center to meet the requirements of transferring cryogenic liquid propellants from storage tanks to an engine in reduced gravity environments. The prototypical mesh screen channel LAD was fabricated with a mesh screen, covering a rectangular flow channel with a cylindrical outlet tube, and was tested with liquid oxygen (LOX). In order to better understand the performance in various gravity environments and orientations at different liquid submersion depths of the screen channel LAD, a series of computational fluid dynamics (CFD) simulations of LOX flow through the LAD screen channel was undertaken. The resulting velocity vector field visualization for the flow in the channel has been used to reveal the gravity effects on the flow in the screen channel.

  5. Multiplex PCR method for use in real-time PCR for identification of fish fillets from grouper (Epinephelus and Mycteroperca species) and common substitute species.

    PubMed

    Trotta, Michele; Schönhuth, Susana; Pepe, Tiziana; Cortesi, M Luisa; Puyet, Antonio; Bautista, José M

    2005-03-23

    Mitochondrial 16S rRNA sequences from morphological validated grouper (Epinephelus aeneus, E. caninus, E. costae, and E. marginatus; Mycteroperca fusca and M. rubra), Nile perch (Lates niloticus), and wreck fish (Polyprion americanus) were used to develop an analytical system for group diagnosis based on two alternative Polymerase Chain Reaction (PCR) approaches. The first includes conventional multiplex PCR in which electrophoretic migration of different sizes of bands allowed identification of the fish species. The second approach, involving real-time PCR, produced a single amplicon from each species that showed different Tm values allowing the fish groups to be directly identified. Real-time PCR allows the quick differential diagnosis of the three groups of species and high-throughput screening of multiple samples. Neither PCR system cross-reacted with DNA samples from 41 common marketed fish species, thus conforming to standards for species validation. The use of these two PCR-based methods makes it now possible to discriminate grouper from substitute fish species.

  6. How fish swim: flexible fin thrusters as an EAP platform

    NASA Astrophysics Data System (ADS)

    Lauder, George V.

    2007-04-01

    Fish are capable of remarkable locomotor performance and use their fins extensively for both propulsion and maneuvering. Recent interest in using fishes as inspiration for the design of a new generation of autonomous underwater vehicles has prompted both new experimental studies of fish locomotor function and efforts to use electroactive polymers (EAP) as actuators in fish-inspired propulsive devices. The fins of fishes allow precise control over body position and vectoring of thrust during propulsion and maneuvering. Recent experimental studies of fish locomotion have revealed that fins exhibit much greater flexibility than previously suspected and that there is considerable deformation of the fin surface during locomotion. The fins of the large group known as ray-finned fishes are supported by fin rays, which have a bilaminar structure that allows active curvature control of the ray and fin surface by the fin musculature. Fish have up to seven different fins, and these fins may interact with each other hydrodynamically during locomotion. Fish fins provide an excellent test platform for the use of electroactive polymer actuators as the frequency of movement is typically less than 5 Hz, and fin muscle strains typically range from 2 to 10%. Recent developments of biorobotic fish pectoral fins actuated with EAP are reviewed.

  7. Pointright: a system to redirect mouse and keyboard control among multiple machines

    DOEpatents

    Johanson, Bradley E [Palo Alto, CA; Winograd, Terry A [Stanford, CA; Hutchins, Gregory M [Mountain View, CA

    2008-09-30

    The present invention provides a software system, PointRight, that allows for smooth and effortless control of pointing and input devices among multiple displays. With PointRight, a single free-floating mouse and keyboard can be used to control multiple screens. When the cursor reaches the edge of a screen it seamlessly moves to the adjacent screen and keyboard control is simultaneously redirected to the appropriate machine. Laptops may also redirect their keyboard and pointing device, and multiple pointers are supported simultaneously. The system automatically reconfigures itself as displays go on, go off, or change the machine they display.

  8. A comparative analysis of somatolactin-related immunoreactivity in the pituitaries of four neopterygian fishes and one chondrostean fish: an immunohistochemical study.

    PubMed

    Dores, R M; Hoffman, N E; Chilcutt-Ruth, T; Lancha, A; Brown, C; Marra, L; Youson, J

    1996-04-01

    An antiserum to cod somatolactin (SL) was used for immunohistochemical screening for the pars intermedia of two teleosts (Oreochromis mossambicus and Gymothorax meleagris), two holostean fishes (Lepisosteus osseus and Amia calva), and a chondrostean fish (Acipenser fulvescens) for SL-immunopositive (SL-IR) cells. As expected, a subset of the epithelial cells in the pars intermedia of O. mossambicus (tilapia) was immunopositive for SL, and the remainder of the epithelial cells was immunopositive for alpha-MSH-specific antiserum (alpha-MSH-IR). SL-IR was not detected in any of the epithelial cells in the pars intermedia of the moray eel G. meleagris. To determine whether SL-IR could be detected in nonteleost fishes, immunohistochemical analyses were done on the pituitaries of two holostean fishes and one chondrostean fish. In the pars intermedia of the gar, L. osseus, a subset of cells was immunopositive for alpha-MSH only. However, in the pars intermedia of the bowfin, A. calva, all of the epithelial cells indicated the presence of both SL and alpha-MSH. Finally, no SL-positive cells were detected in the pars intermedia of the sturgeon, A. fulvescens.

  9. Noninvasive type 2 diabetes screening: superior sensitivity to fasting plasma glucose and A1C.

    PubMed

    Maynard, John D; Rohrscheib, Mark; Way, Jeffrey F; Nguyen, Catriona M; Ediger, Marwood N

    2007-05-01

    This study compared the performance of a novel noninvasive technology to fasting plasma glucose (FPG) and A1C tests for detecting undiagnosed diabetes and impaired glucose tolerance. The design was a head-to-head evaluation in a naïve population. Consented subjects received FPG and A1C tests and an oral glucose tolerance test (OGTT). Subjects were also measured by a noninvasive device that detects the fluorescence of skin advanced glycation end products. A total of 351 subjects participated. Subjects with 2-h OGTT values > or = 140 mg/dl defined the positive screening class. A total of 84 subjects (23.9% prevalence) screened positive. The performances of the noninvasive device, FPG, and A1C were evaluated for sensitivity and specificity against this classification. At the impaired fasting glucose threshold (FPG = 100 mg/dl), the FPG testing sensitivity was 58% and the specificity was 77.4%. At that same specificity, the sensitivity for A1C testing was 63.8%, while the noninvasive testing sensitivity was 74.7%. The sensitivity advantage of the noninvasive device over both blood tests for detecting diabetes and precursors was statistically significant (P < 0.05). The noninvasive technology showed clinical performance advantages over both FPG and A1C testing. The sensitivity differential indicated that the noninvasive device is capable of identifying 28.8% more individuals in the OGTT-defined positive screening class than FPG testing and 17.1% more than A1C testing. The combination of higher sensitivity and greater convenience--rapid results with no fasting or blood draws--makes the device well suited for opportunistic screening.

  10. Application of protein expression profiling to screen chemicals for androgenic activity.

    PubMed

    Hemmer, Michael J; Salinas, Kimberly A; Harris, Peggy S

    2011-05-01

    Protein expression changes can be used for detection of biomarkers that can be applied diagnostically to screen chemicals for endocrine modifying activity. In this study, surface enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) coupled with a short term fish assay was used to investigate changes in plasma protein expression as a means to screen chemicals for androgenic activity. Adult gravid female sheepshead minnows (Cyprinodon variegatus) were placed into separate aquaria for seawater control, ethanol solvent control, and the following androgen agonist treatments at 5.0μg/L: dihydrotestosterone (DHT), methyldihydrotestosterone (MDHT), testosterone (T), methyltestosterone (MT) and trenbolone (TB). Treatments of 0.6μg/L endosulfan and 40μg/L chlorpyrifos (CP) served as non-androgenic negative stressor controls. Test concentrations were maintained using an intermittent flow-through dosing apparatus supplying exposure water at 20L/h. Fish were sampled at 7 days, the plasma diluted, processed on weak cation exchange CM10 ProteinChip arrays and analyzed. Spectral processing resulted in 249 individual m/z peak clusters for the androgen exposed fish. Partial least squares-discriminant analysis was used to develop an androgen-responsive model using sample spectra from exposures with DHT and unexposed solvent control fish as the training set. The androgen classification model performed with ≥79% specificity (% true negative) and ≥70% sensitivity (% true positive) for non-aromatizable androgens. The aromatizable androgens T and MT were classified as androgenic with specificities of 42 and 79%, respectively. The reduction in sensitivity observed with T is thought to be caused by its metabolic conversion to an estrogen by aromatase. The results of these studies show diagnostic plasma protein expression models can correctly classify chemicals by their androgenic activity using a combination of high throughput mass spectrometry and multivariate approaches. Published by Elsevier B.V.

  11. Fish play Minority Game as humans do

    NASA Astrophysics Data System (ADS)

    Liu, Ruey-Tarng; Chung, Fei Fang; Liaw, Sy-Sang

    2012-01-01

    We report the results of an unprecedented real Minority Game (MG) played by university staff members who clicked one of two identical buttons (A and B) on a computer screen while clocking in or out of work. We recorded the number of people who clicked button A for 1288 games, beginning on April 21, 2008 and ending on October 31, 2010, and calculated the variance among the people who clicked A as a function of time. The evolution of the variance shows that the global gain of selfish agents increases when a small portion of agents make persistent choice in the games. We also carried out another experiment in which we forced 101 fish to enter one of the two symmetric chambers (A and B). We repeated the fish experiment 500 times and found that the variance of the number of fish that entered chamber A evolved in a way similar to the human MG, suggesting that fish have memory and can employ more strategies when facing the same situation again and again.

  12. Elimination of persistent organic pollutants from fish oil with solid adsorbents.

    PubMed

    Ortiz, X; Carabellido, L; Martí, M; Martí, R; Tomás, X; Díaz-Ferrero, J

    2011-02-01

    Fish oils are one of the main sources of ω-3 fatty acids in animal and human diet. However, they can contain high concentrations of persistent organic pollutants due to their lipophilic properties. The aim of this study is the reduction of persistent organic pollutants in fish oil using silicon-based and carbon-based solid adsorbents. A wide screening study with different commercially available adsorbents was carried out, in order to determine their capacity of pollutant removal from fish oil. Moreover, adsorption conditions were evaluated and optimized with using an experimental design and adjustment of the experimental results to response surfaces, obtaining removals rates of more than 99% of PCDD/Fs, 81% of dioxin-like PCBs, 70% of HCB, 41% of DDTs, 16% of marker PCBs and 10% of PBDEs. Finally, fish oil fatty acids were analyzed before and after the treatment with solid adsorbents, confirming that it did not affect its nutritive properties. Copyright © 2010 Elsevier Ltd. All rights reserved.

  13. Accurate Identification of ALK Positive Lung Carcinoma Patients: Novel FDA-Cleared Automated Fluorescence In Situ Hybridization Scanning System and Ultrasensitive Immunohistochemistry

    PubMed Central

    Conde, Esther; Suárez-Gauthier, Ana; Benito, Amparo; Garrido, Pilar; García-Campelo, Rosario; Biscuola, Michele; Paz-Ares, Luis; Hardisson, David; de Castro, Javier; Camacho, M. Carmen; Rodriguez-Abreu, Delvys; Abdulkader, Ihab; Ramirez, Josep; Reguart, Noemí; Salido, Marta; Pijuán, Lara; Arriola, Edurne; Sanz, Julián; Folgueras, Victoria; Villanueva, Noemí; Gómez-Román, Javier; Hidalgo, Manuel; López-Ríos, Fernando

    2014-01-01

    Background Based on the excellent results of the clinical trials with ALK-inhibitors, the importance of accurately identifying ALK positive lung cancer has never been greater. However, there are increasing number of recent publications addressing discordances between FISH and IHC. The controversy is further fuelled by the different regulatory approvals. This situation prompted us to investigate two ALK IHC antibodies (using a novel ultrasensitive detection-amplification kit) and an automated ALK FISH scanning system (FDA-cleared) in a series of non-small cell lung cancer tumor samples. Methods Forty-seven ALK FISH-positive and 56 ALK FISH-negative NSCLC samples were studied. All specimens were screened for ALK expression by two IHC antibodies (clone 5A4 from Novocastra and clone D5F3 from Ventana) and for ALK rearrangement by FISH (Vysis ALK FISH break-apart kit), which was automatically captured and scored by using Bioview's automated scanning system. Results All positive cases with the IHC antibodies were FISH-positive. There was only one IHC-negative case with both antibodies which showed a FISH-positive result. The overall sensitivity and specificity of the IHC in comparison with FISH were 98% and 100%, respectively. Conclusions The specificity of these ultrasensitive IHC assays may obviate the need for FISH confirmation in positive IHC cases. However, the likelihood of false negative IHC results strengthens the case for FISH testing, at least in some situations. PMID:25248157

  14. Screening for antibacterial activity of some Turkish plants against fish pathogens: a possible alternative in the treatment of bacterial infections

    PubMed Central

    Turker, Hakan; Yıldırım, Arzu Birinci

    2015-01-01

    The antibacterial activity of ethanolic and aqueous crude extracts from 36 plants in Turkey, including seven endemic species, against fish pathogens was studied using the disc diffusion assay. The extract that was most active against all microbial strains, except Aeromonas salmonicida, was that of Dorycnium pentaphyllum. Some of the extracts also showed a very broad spectrum of potent antimicrobial activity. The extract of Anemone nemorosa showed the highest antimicrobial activity against Vibrio anguillarum. V. anguillarum, a Gram-negative bacterium, appeared to be the most susceptible to the plant extracts used in this experiment. To the best of our knowledge, this is the first report on the antimicrobial activity of 11 of the studied plants. The preliminary screening assay indicated that some of the Turkish plants with antibacterial properties may offer alternative therapeutic agents against bacterial infections in aquaculture industry. PMID:26019642

  15. Microfluidic devices for the controlled manipulation of small volumes

    DOEpatents

    Ramsey, Michael J; Jacobson, Stephen C

    2012-09-18

    A method for conducting a broad range of biochemical analyses or manipulations on a series of nano- to subnanoliter reaction volumes and an apparatus for carrying out the same are disclosed. The invention is implemented on a fluidic microchip to provide high serial throughput. In particular, the disclosed device is a microfabricated channel device that can manipulate nanoliter or subnanoliter reaction volumes in a controlled manner to produce results at rates of 1 to 10 Hz per channel. The reaction volumes are manipulated in serial fashion analogous to a digital shift register. The invention has application to such problems as screening molecular or cellular targets using single beads from split-synthesis combinatorial libraries, screening single cells for RNA or protein expression, genetic diagnostic screening at the single cell level, or performing single cell signal transduction studies.

  16. Development of design, qualification, screening, and application requirements for plastic encapsulated solid-state devices for space applications

    NASA Astrophysics Data System (ADS)

    1981-12-01

    Test data were collected on 1035 plastic encapsulated devices and 75 hermetically scaled control group devices that were purchased from each of five different manufacturers in the categories of (1) low power Schottsky TTL (bipolar) digital circuits; (2) CMOS digital circuits; (3) operational amplifier linear circuits; and (4) NPN transistors. These parts were subjected to three different initial screening conditions, then to extended life testing, to determine any possible advantages or trends for any particular screen. Several tests were carried out in the areas of flammability testing, humidity testing, high pressure steam (auroclave) testing, and high temperature storage testing. Test results are presented. Procurement and application considerations for use of plastic encapsulated semiconductors are presented and a statistical analysis program written to study the log normal distributions resulting from life testing is concluded.

  17. Development of design, qualification, screening, and application requirements for plastic encapsulated solid-state devices for space applications

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Test data were collected on 1035 plastic encapsulated devices and 75 hermetically scaled control group devices that were purchased from each of five different manufacturers in the categories of (1) low power Schottsky TTL (bipolar) digital circuits; (2) CMOS digital circuits; (3) operational amplifier linear circuits; and (4) NPN transistors. These parts were subjected to three different initial screening conditions, then to extended life testing, to determine any possible advantages or trends for any particular screen. Several tests were carried out in the areas of flammability testing, humidity testing, high pressure steam (auroclave) testing, and high temperature storage testing. Test results are presented. Procurement and application considerations for use of plastic encapsulated semiconductors are presented and a statistical analysis program written to study the log normal distributions resulting from life testing is concluded.

  18. Microfluidic devices for the controlled manipulation of small volumes

    DOEpatents

    Ramsey, J Michael [Knoxville, TN; Jacobson, Stephen C [Knoxville, TN

    2007-07-03

    A method for conducting a broad range of biochemical analyses or manipulations on a series of nano- to subnanoliter reaction volumes and an apparatus for carrying out the same are disclosed. The invention is implemented on a fluidic microchip to provide high serial throughput. In particular, the disclosed device is a microfabricated channel device that can manipulate nanoliter or subnanoliter reaction volumes in a controlled manner to produce results at rates of 1 to 10 Hz per channel. The reaction volumes are manipulated in serial fashion analogous to a digital shift register. The invention has application to such problems as screening molecular or cellular targets using single beads from split-synthesis combinatorial libraries, screening single cells for RNA or protein expression, genetic diagnostic screening at the single cell level, or performing single cell signal transduction studies.

  19. Sorptive capacity of membrane lipids, storage lipids, and proteins: a preliminary study of partitioning of organochlorines in lean fish from a PCB-contaminated freshwater lake.

    PubMed

    Mäenpää, Kimmo; Leppänen, Matti T; Figueiredo, Kaisa; Tigistu-Sahle, Feven; Käkelä, Reijo

    2015-01-01

    Knowledge on the internal distribution of halogenated organic chemicals (HOCs) would improve our understanding of dose-effect relationships and subsequently improve risk assessment of contaminated sites. Herein, we determine the concentrations of HOCs based on equilibrium partitioning in storage lipids, membrane lipids, and proteins in field-contaminated fish using equilibrium sampling devices. The study shows the importance of protein as a sorptive phase in lean fish. Our results provide a basis for using species-specific equilibrium partitioning coefficients between sorptive tissues and fish internal water as a substitute for K(ow) in, for example, upgrading models that simulate food-chain accumulation of the chemical.

  20. Impact of e-Discipline on Children's Screen Time.

    PubMed

    Hawi, Nazir S; Rupert, Maya Samaha

    2015-06-01

    With rapid technological advancement, the prevalence and undesirable effects of excess screen time on children have become a mounting issue worldwide. There are many studies investigating the phenomenon's impact on society (e.g., behavioral, academic, health), but studies that uncover the causes and factors that increase the odds of children's excess screen time are limited. To this end, this study introduces the term "e-discipline" to refer to systematic practices that use screen devices as discipline tools. As such, the aim of this study is to investigate the association between e-discipline and children's screen time by gender. Analysis was performed on 3,141 children aged 7-11 years old. Bivariate logistic regression models were used to calculate the odds of exceeding the American Academy of Pediatrics guidelines of 2 hours of screen time per day by boys and girls whose parents practice e-discipline. The results showed that children whose parents used screen devices as discipline tools had significantly more screen time compared to children whose parents did not. Furthermore, no statistically significant gender differences were found in the odds of exceeding the recommended screen time under e-discipline. Recommendations stemming from all the results are discussed.

  1. Sociodemographic, home environment and parental influences on total and device-specific screen viewing in children aged 2 years and below: an observational study

    PubMed Central

    Goh, Si Ning; Teh, Long Hua; Tay, Wei Rong; Anantharaman, Saradha; van Dam, Rob M; Tan, Chuen Seng; Chua, Hwee Ling; Wong, Pey Gein; Müller-Riemenschneider, Falk

    2016-01-01

    Objective This study aimed to investigate total and device-specific screen viewing (SV) and its determinants in children aged 2 years and below. Design Cross-sectional study conducted in February 2014. Setting Well-child clinics in Singapore national polyclinics. Participants Parents of children (Singapore citizens or permanent residents) aged 2 years and below were enrolled during routine clinic visits. Out of 794 eligible parent–child dyads, 725 (91.3%) provided informed consent and were included in the analysis. Main outcome measures Device-specific information on SV and determinants was ascertained using interviewer-administered survey questionnaires. The prevalence and duration of aggregate and device-specific SV were reported. Associations with potential determinants were investigated using multiple logistic regression analysis. A p value less than 0.05 was considered statistically significant. Results The prevalence of daily SV and SV ≥2 h/day constituted 53.5% and 16.3%, respectively. The majority of children aged 18–24 months (88.2%) engaged in daily SV. TVs and mobile devices were the most commonly used screen devices, followed by computers and video consoles. In multivariable analysis, younger child age, Chinese ethnicity and setting rules on time of SV were strongly and consistently associated with lower levels of any SV and SV ≥2 h/day. Parental knowledge of SV recommendations and less parental SV were additionally associated with lower levels of SV ≥2 h/day. The number of screen devices was not associated with children's SV. Conclusions In contrast to recommendations, SV prevalence in children aged less than 2 years is high and appears to increase steadily across age groups. TVs and mobile devices are most frequently used. Improving parental knowledge of SV recommendations, reducing parental SV and especially the implementation of strict rules on SV time could be successful strategies to reduce SV in young children. PMID:26810995

  2. Usability of digital media in patients with COPD: a pilot study.

    PubMed

    Cheung, Amy; Janssen, Anton; Amft, Oliver; Wouters, Emiel F M; Spruit, Martijn A

    2013-04-01

    Digital media can be integrated in tele-monitoring solutions, serving as the main interface between the patient and the caregiver. Consequently, the selection of the most appropriate digital medium for the specified target group is critical to ensure compliance with the tele-monitoring system. This pilot study aims to gather insights from patients with chronic obstructive pulmonary disease (COPD) on the ease-of-use, efficacy, effectiveness, and satisfaction of different types of digital media. Five off-the-shelf digital media devices were tested on nine patients at CIRO+ in Horn, The Netherlands. Usability was evaluated by asking patients to use each device to answer questions related to their symptoms and health status. Subsequently, patients completed a paper-based device usability questionnaire, which assessed prior experience with digital media, device dimensions, device controllability, response speed, screen readability, ease-of-use, and overall satisfaction. After testing all the devices, patients ranked the devices according to their preference. We identified the netbook as the preferred type of device due to its good controllability, fast response time, and large screen size. The smartphone was the least favorite device as patients found the size of the screen to be too small, which made it difficult to interact with. The pilot study has provided important insights to guide the selection of the most appropriate type of digital medium for implementation in tele-monitoring solutions for patients with COPD. As the digital medium is an important interface to the patient in tele-monitoring solutions, it is essential that patients feel motivated to interact with the digital medium on a regular basis.

  3. Electromagnetic radiation screening of microcircuits for long life applications

    NASA Technical Reports Server (NTRS)

    Brammer, W. G.; Erickson, J. J.; Levy, M. E.

    1974-01-01

    The utility of X-rays as a stimulus for screening high reliability semiconductor microcircuits was studied. The theory of the interaction of X-rays with semiconductor materials and devices was considered. Experimental measurements of photovoltages, photocurrents, and effects on specified parameters were made on discrete devices and on microcircuits. The test specimens included discrete devices with certain types of identified flaws and symptoms of flaws, and microcircuits exhibiting deviant electrical behavior. With a necessarily limited sample of test specimens, no useful correlation could be found between the X-ray-induced electrical response and the known or suspected presence of flaws.

  4. Prospective and clinical validation of ALK immunohistochemistry: results from the phase I/II study of alectinib for ALK-positive lung cancer (AF-001JP study).

    PubMed

    Takeuchi, K; Togashi, Y; Kamihara, Y; Fukuyama, T; Yoshioka, H; Inoue, A; Katsuki, H; Kiura, K; Nakagawa, K; Seto, T; Maemondo, M; Hida, T; Harada, M; Ohe, Y; Nogami, N; Yamamoto, N; Nishio, M; Tamura, T

    2016-01-01

    Anaplastic lymphoma kinase (ALK) fusions need to be accurately and efficiently detected for ALK inhibitor therapy. Fluorescence in situ hybridization (FISH) remains the reference test. Although increasing data are supporting that ALK immunohistochemistry (IHC) is highly concordant with FISH, IHC screening needed to be clinically and prospectively validated. In the AF-001JP trial for alectinib, 436 patients were screened for ALK fusions through IHC (n = 384) confirmed with FISH (n = 181), multiplex RT-PCR (n = 68), or both (n = 16). IHC results were scored with iScore. ALK fusion was positive in 137 patients and negative in 250 patients. Since the presence of cancer cells in the samples for RT-PCR was not confirmed, ALK fusion negativity could not be ascertained in 49 patients. IHC interpreted with iScore showed a 99.4% (173/174) concordance with FISH. All 41 patients who had iScore 3 and were enrolled in phase II showed at least 30% tumor reduction with 92.7% overall response rate. Two IHC-positive patients with an atypical FISH pattern responded to ALK inhibitor therapy. The reduction rate was not correlated with IHC staining intensity. Our study showed (i) that when sufficiently sensitive and appropriately interpreted, IHC can be a stand-alone diagnostic for ALK inhibitor therapies; (ii) that when atypical FISH patterns are accompanied by IHC positivity, the patients should be considered as candidates for ALK inhibitor therapies, and (iii) that the expression level of ALK fusion is not related to the level of response to ALK inhibitors and is thus not required for patient selection. JapicCTI-101264 (This study is registered with the Japan Pharmaceutical Information Center). © The Author 2015. Published by Oxford University Press on behalf of the European Society for Medical Oncology.

  5. Environmental contaminants in freshwater fish and their risk to piscivorous wildlife based on a national monitoring program

    USGS Publications Warehouse

    Hinck, J.E.; Schmitt, C.J.; Chojnacki, K.A.; Tillitt, D.E.

    2009-01-01

    Organochlorine chemical residues and elemental concentrations were measured in piscivorous and benthivorous fish at 111 sites from large U.S. river basins. Potential contaminant sources such as urban and agricultural runoff, industrial discharges, mine drainage, and irrigation varied among the sampling sites. Our objectives were to provide summary statistics for chemical contaminants and to determine if contaminant concentrations in the fish were a risk to wildlife that forage at these sites. Concentrations of dieldrin, total DDT, total PCBs, toxaphene, TCDD-EQ, cadmium, chromium, mercury, lead, selenium, and zinc exceeded toxicity thresholds to protect fish and piscivorous wildlife in samples from at least one site; most exceedences were for total PCBs, mercury, and zinc. Chemical concentrations in fish from the Mississippi River Basin exceeded the greatest number of toxicity thresholds. Screening level wildlife risk analysis models were developed for bald eagle and mink using no adverse effect levels (NOAELs), which were derived from adult dietary exposure or tissue concentration studies and based primarily on reproductive endpoints. No effect hazard concentrations (NEHC) were calculated by comparing the NOAEL to the food ingestion rate (dietary-based NOAEL) or biomagnification factor (tissue-based NOAEL) of each receptor. Piscivorous wildlife may be at risk from a contaminant if the measured concentration in fish exceeds the NEHC. Concentrations of most organochlorine residues and elemental contaminants represented no to low risk to bald eagle and mink at most sites. The risk associated with pentachloroanisole, aldrin, Dacthal, methoxychlor, mirex, and toxaphene was unknown because NOAELs for these contaminants were not available for bald eagle or mink. Risk differed among modeled species and sites. Our screening level analysis indicates that the greatest risk to piscivorous wildlife was from total DDT, total PCBs, TCDD-EQ, mercury, and selenium. Bald eagles were at greater risk to total DDT and total PCBs than mink, whereas risks of TCDD-EQ, mercury, and selenium were greater to mink than bald eagle. ?? Springer Science+Business Media B.V. 2008.

  6. Fabricating Simple Wax Screen-Printing Paper-Based Analytical Devices to Demonstrate the Concept of Limiting Reagent in Acid- Base Reactions

    ERIC Educational Resources Information Center

    Namwong, Pithakpong; Jarujamrus, Purim; Amatatongchai, Maliwan; Chairam, Sanoe

    2018-01-01

    In this article, a low-cost, simple, and rapid fabrication of paper-based analytical devices (PADs) using a wax screen-printing method is reported here. The acid-base reaction is implemented in the simple PADs to demonstrate to students the chemistry concept of a limiting reagent. When a fixed concentration of base reacts with a gradually…

  7. Irradiate-anneal screening of total dose effects in semiconductor devices. [radiation hardening of spacecraft components of Mariner spacecraft

    NASA Technical Reports Server (NTRS)

    Stanley, A. G.; Price, W. E.

    1976-01-01

    An extensive investigation of irradiate-anneal (IRAN) screening against total dose radiation effects was carried out as part of a program to harden the Mariner Jupiter/Saturn 1977 (MJS'77) spacecraft to survive the Jupiter radiation belts. The method consists of irradiating semiconductor devices with Cobalt-60 to a suitable total dose under representative bias conditions and of separating the parts in the undesired tail of the distribution from the bulk of the parts by means of a predetermined acceptance limit. The acceptable devices are then restored close to their preirradiation condition by annealing them at an elevated temperature. IRAN was used when lot screen methods were impracticable due to lack of time, and when members of a lot showed a diversity of radiation response. The feasibility of the technique was determined by testing of a number of types of linear bipolar integrated circuits, analog switches, n-channel JFETS and bipolar transistors. Based on the results of these experiments a number of device types were selected for IRAN of flight parts in the MJS'77 spacecraft systems. The part types, screening doses, acceptance criteria, number of parts tested and rejected as well as the program steps are detailed.

  8. Evaluation of colorimetric loop-mediated isothermal amplification assay for visual detection of Streptococcus agalactiae and Streptococcus iniae in tilapia.

    PubMed

    Suebsing, R; Kampeera, J; Tookdee, B; Withyachumnarnkul, B; Turner, W; Kiatpathomchai, W

    2013-10-01

    Streptococcus agalactiae and Strep. iniae are bacterial pathogens that cause streptococcosis in many fish species. An accelerated colorimetric loop-mediated isothermal amplification (LAMP) assay with pre-addition of calcein was established, and the transmission and detection of Strep. agalactiae and Strep. iniae in tilapia under natural aquatic environment were investigated. A positive reaction was observed by a colour change from orange to green through the naked eyes after completion at 63°C for 30 min with 10 times higher sensitivity than that of nested PCR assays and without cross-amplification with other fish bacterial pathogens. All sample types of Nile and red tilapia (broodstock, fertilized egg, fry) were Strep. agalactiae- and Strep. iniae positive by this new method, implying that they could be vertically transmitted. With its application for screening broodstock and fry before stocking and for monitoring fish health in grow-out ponds, the method would become very useful in fish farming industry. The application of colorimetric LAMP with pre-addition of calcein offers simple, rapid and sensitive technique with applicability for small field laboratories. This technique explored the possible vertical transmission mode of Strep. agalactiae and Strep. iniae under natural aquatic environment. It could be such preliminary data provided for the screening broodstock before breeding and/or the specific-pathogen-free production. © 2013 The Society for Applied Microbiology.

  9. Multi-residue determination of seventeen sulfonamides and five tetracyclines in fish tissue using a multi-stage LC-ESI-MS/MS approach based on advanced mass spectrometric techniques.

    PubMed

    Dasenaki, Marilena E; Thomaidis, Nikolaos S

    2010-07-05

    A strategy was newly developed to rapidly screen seventeen sulfonamides and five tetracyclines in a single run from fish tissues using ultra-high performance liquid chromatography (UHPLC) coupled with comprehensive mass spectrometric approaches, including precursor-ion scan and data dependent scan. The product ions for precursor-ion scanning were selected by studying the MS/MS fragmentation of the analytes. All sulfonamides share the same diagnostic product ion at m/z 156 in positive MS/MS scan, while for tetracycline antibiotics the diagnostic product ion was proved to be at m/z 153.8. Further characterization of each compound was performed using a data dependent scan. Separation was performed on a Zorbax Eclipse Plus C18 column with a gradient elution using acetonitrile - 0.1% formic acid mobile phase at a flow rate of 0.1 mL min(-1). This approach has proven to be a powerful, highly selective, and sensitive tool for rapid screening and detection of non-targeted components in fish tissue and requires a minimum sample preparation such as one generic extraction step with MeOH:ACN 50:50 (v/v) acidified with 0.05% formic acid. The method has also been applied successfully to porcine and poultry meat. The validation of such a screening method was performed for the first time according to Commission Decision 2002/657/EC and satisfactory method performance characteristics were achieved. Copyright 2010 Elsevier B.V. All rights reserved.

  10. A novel screen-printed mast cell-based electrochemical sensor for detecting spoilage bacterial quorum signaling molecules (N-acyl-homoserine-lactones) in freshwater fish.

    PubMed

    Jiang, Donglei; Liu, Yan; Jiang, Hui; Rao, Shengqi; Fang, Wu; Wu, Mangang; Yuan, Limin; Fang, Weiming

    2018-04-15

    A novel screen-printed cell-based electrochemical sensor was developed to assess bacterial quorum signaling molecules, N-acylhomoserine lactones (AHLs). Screen-printed carbon electrode (SPCE), which possesses excellent properties such as low-cost, disposable and energy-efficient, was modified with multi-walled carbon nanotubes (MWNTs) to improve electrochemical signals and enhance the sensitivity. Rat basophilic leukemia (RBL-2H3) mast cells encapsulated in alginate/graphene oxide (NaAgl/GO) hydrogel were immobilized on the MWNTs/SPCE to serve as recognition element. Electrochemical impedance spectroscopy (EIS) was employed to record the cell impedance signal as-influenced by Pseudomonas aeruginosa quorum-sensing molecule, N-3-oxododecanoyl homoserine lactone (3OC 12 -HSL). Experimental results show that 3OC 12 -HSL caused a significant decrease in cell viability in a dose dependent manner. The EIS value decreased with concentrations of 3OC 12 -HSL in the range of 0.1-1μM, and the detection limit for 3OC 12 -HSL was calculated to be 0.094μM. These results were confirmed via cell viability, SEM, TEM analysis. Next, the sensor was successfully applied to monitoring the production of AHLs by spoilage bacteria in three different freshwater fish juice samples which efficiently proved the practicability of this cell based method. Therefore, the proposed cell sensor may serve as an innovative and effective approach to the measurement of quorum signaling molecule and thus provides a new avenue for real-time monitoring the spoilage bacteria in freshwater fish production. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. A Global View of Large-Scale Commercial Fishing

    NASA Astrophysics Data System (ADS)

    Kroodsma, D.

    2016-12-01

    Advances in big data processing and satellite technology, combined with the widespread adoption of Automatic Identification System (AIS) devices, now allow the monitoring of fishing activity at a global scale and in high resolution. We analyzed AIS data from more than 40,000 vessels from 2012-2015 to produce 0.1 degree global daily maps of apparent fishing effort. Vessels were matched to publically accessible fishing vessel registries and identified as fishing vessels through AIS Type 5 and Type 24 self-reported messages. Fishing vessels that broadcasted false locations in AIS data were excluded from the analysis. To model fishing pattern classification, a subset of fishing vessels were analyzed and specific movements were classified as "fishing" or "not fishing." A logistic regression model was fitted to these classifications using the following features: a vessel's average speed, the standard deviation of its speed, and the standard deviation of its course over a 12 hour time window. We then applied this model to the entire fishing vessel dataset and time normalized it to produce a global map of fishing hours. The resulting dataset allows for numerous new analyses. For instance, it can assist with monitoring apparent fishing activity in large pelagic marine protected areas and restricted gear use areas, or it can quantify how activity may be affected by seasonal or annual changes in biological productivity. This dataset is now published and freely available in Google's Earth Engine platform, available for researchers to answer a host of questions related to global fishing effort.

  12. Identification of Volunteer Screening Practices for Selected Ohio Youth Organizations.

    ERIC Educational Resources Information Center

    Henderson, Jan; Schmiesing, Ryan J.

    2001-01-01

    Interviews with eight coordinators of youth organization volunteers indicated that most used position descriptions, applications, reference checks, and interviews as screening tools; only four checked motor vehicle records and three checked criminal records. Consistent policies and advanced screening devices were recommended. (SK)

  13. Integrated fountain effect pump device for fluid management at low gravity

    NASA Technical Reports Server (NTRS)

    Yuan, S. W. K.; Frank, D. J.

    1988-01-01

    A new device for fluid management at low gravity is described. The system is basically the same as the enclosed capillary device using screens, in which the screens along the gallery channels are replaced by porous plugs which are responsible for both the fluid retention and pumping of He II; in this device, no downstream pump is needed. The plugs in contact with liquid He on both sides act as a fountain-effect pumps (FEPs), while plugs exposed to vapor on one side behave as vapor-liquid phase separators (VLPSs). The total net rate of He II transfer into the receiving tank equals the mass flow rate through the FEP plugs minus the liquid loss from the VLPS plugs. The results of the performance analysis of this integrated FEP device are presented together with its schematic diagram.

  14. Correlates of mobile screen media use among children aged 0–8: a systematic review

    PubMed Central

    Jancey, Jonine; Subedi, Narayan; Leavy, Justine

    2017-01-01

    Objective This study is a systematic review of the peer-reviewed literature to identify the correlates of mobile screen media use among children aged 8 years and less. Setting Home or community-based studies were included in this review while child care or school-based studies were excluded. Participants Children aged 8 years or less were the study population. Studies that included larger age groups without subgroup analysis specific to the 0–8 years category were excluded. Eight electronic databases were searched for peer-reviewed English language primary research articles published or in press between January 2009 and March 2017 that have studied correlates of mobile screen media use in this age group. Outcome measure Mobile screen media use was the primary outcome measure. Mobile screen media use refers to children’s use of mobile screens, such as mobile phones, electronic tablets, handheld computers or personal digital assistants. Results Thirteen studies meeting the inclusion criteria were identified of which a total of 36 correlates were examined. Older children, children better skilled in using mobile screen media devices, those having greater access to such devices at home and whose parents had high mobile screen media use were more likely to have higher use of mobile screen media devices. No association existed with parent’s age, sex and education. Conclusion Limited research has been undertaken into young children’s mobile screen media use and most of the variables have been studied too infrequently for robust conclusions to be reached. Future studies with objective assessment of mobile screen media use and frequent examination of the potential correlates across multiple studies and settings are recommended. Trial registration number This review is registered with PROSPERO International Prospective Register of Ongoing Systematic Reviews (registration number: CRD42015028028). PMID:29070636

  15. Correlates of mobile screen media use among children aged 0-8: a systematic review.

    PubMed

    Paudel, Susan; Jancey, Jonine; Subedi, Narayan; Leavy, Justine

    2017-10-24

    This study is a systematic review of the peer-reviewed literature to identify the correlates of mobile screen media use among children aged 8 years and less. Home or community-based studies were included in this review while child care or school-based studies were excluded. Children aged 8 years or less were the study population. Studies that included larger age groups without subgroup analysis specific to the 0-8 years category were excluded. Eight electronic databases were searched for peer-reviewed English language primary research articles published or in press between January 2009 and March 2017 that have studied correlates of mobile screen media use in this age group. Mobile screen media use was the primary outcome measure. Mobile screen media use refers to children's use of mobile screens, such as mobile phones, electronic tablets, handheld computers or personal digital assistants. Thirteen studies meeting the inclusion criteria were identified of which a total of 36 correlates were examined. Older children, children better skilled in using mobile screen media devices, those having greater access to such devices at home and whose parents had high mobile screen media use were more likely to have higher use of mobile screen media devices. No association existed with parent's age, sex and education. Limited research has been undertaken into young children's mobile screen media use and most of the variables have been studied too infrequently for robust conclusions to be reached. Future studies with objective assessment of mobile screen media use and frequent examination of the potential correlates across multiple studies and settings are recommended. This review is registered with PROSPERO International Prospective Register of Ongoing Systematic Reviews (registration number: CRD42015028028). © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. Associations between Screen-Based Sedentary Behaviour and Anxiety Symptoms in Mothers with Young Children

    PubMed Central

    Teychenne, Megan; Hinkley, Trina

    2016-01-01

    Objectives Anxiety is a serious illness and women (including mothers with young children) are at particular risk. Although physical activity (PA) may reduce anxiety risk, little research has investigated the link between sedentary behaviour and anxiety risk. The aim of this study was to examine the association between screen-based sedentary behaviour and anxiety symptoms, independent of PA, amongst mothers with young children. Methods During 2013–2014, 528 mothers with children aged 2–5 years completed self-report measures of recreational screen-based sedentary behaviour (TV/DVD/video viewing, computer/e-games/hand held device use) and anxiety symptoms (using the Hospital Anxiety and Depression Scale, HADS-A). Linear regression analyses examined the cross-sectional association between screen-based sedentary behaviour and anxiety symptoms. Results In models that adjusted for key demographic and behavioural covariates (including moderate- to vigorous-intensity PA, MVPA), computer/device use (B = 0.212; 95% CI = 0.048, 0.377) and total screen time (B = 0.109; 95% CI = 0.014, 0.205) were positively associated with heightened anxiety symptoms. TV viewing was not associated with anxiety symptoms in either model. Conclusions Higher levels of recreational computer or handheld device use and overall screen time may be linked to higher risk of anxiety symptoms in mothers with young children, independent of MVPA. Further longitudinal and intervention research is required to determine temporal associations. PMID:27191953

  17. Small Fish Species as Powerful Model Systems to Study Vertebrate Physiology in Space

    NASA Astrophysics Data System (ADS)

    Muller, M.; Aceto, J.; Dalcq, J.; Alestrom, P.; Nourizadeh-Lillabadi, R.; Goerlich, R.; Schiller, V.; Winkler, C.; Renn, J.; Eberius, M.; Slenzka, K.

    2008-06-01

    Small fish models, mainly zebrafish (Danio rerio) and medaka (Oryzias latipes), have been used for many years as powerful model systems for vertebrate developmental biology. Moreover, these species are increasingly recognized as valuable systems to study vertebrate physiology, pathology, pharmacology and toxicology, including in particular bone physiology. The biology of small fishes presents many advantages, such as transparency of the embryos, external and rapid development, small size and easy reproduction. Further characteristics are particularly useful for space research or for large scale screening approaches. Finally, many technologies for easily characterizing bones are available. Our objective is to investigate the changes induced by microgravity in small fish. By combining whole genome analysis (microarray, DNA methylation, chromatin modification) with live imaging of selected genes in transgenic animals, a comprehensive and integrated characterization of physiological changes in space could be gained, especially concerning bone physiology.

  18. Unusual dominance by desert pupfish (Cyprinodon macularius) in experimental ponds within the Salton Sea Basin

    USGS Publications Warehouse

    Saiki, Michael K.; Martin, Barbara A.; Anderson, Thomas W.

    2011-01-01

    In October 2006, months after shallow experimental ponds in the Salton Sea Basin were filled with water from the Alamo River and Salton Sea, fish were observed in several ponds, although inlets had been screened to exclude fish. During October 2007November 2009, nine surveys were conducted using baited minnow traps to document species and relative abundance of fish. Surveys yielded 3,620 fish representing five species. Desert pupfish (Cyprinodon macularius), the only native species encountered, was the most numerous and comprised >93% of the catch. Nonnative species included western mosquitofish (Gambusia affinis, 4.1%), sailfin molly (Poecilia latipinna, 2.8%), and tilapia (a mixture of hybrid Mozambique tilapia Oreochromis mossambicus ?? O. urolepis and redbelly tilapia Tilapia zillii, <0.1%). Dominance by desert pupfish, which persisted over our 2 years of study, was unusual because surveys conducted in nearby agricultural drains yielded relatively few desert pupfish.

  19. Concordance of IHC, FISH and RT-PCR for EML4-ALK rearrangements.

    PubMed

    Teixidó, Cristina; Karachaliou, Niki; Peg, Vicente; Gimenez-Capitan, Ana; Rosell, Rafael

    2014-04-01

    The echinoderm microtubule-associated protein-like 4 anaplastic lymphoma kinase (EML4-ALK) has emerged as the second most important driver oncogene in lung cancer and the first targetable fusion oncokinase to be identified in 4-6% of lung adenocarcinomas. Crizotinib, along with a diagnostic test-the Vysis ALK Break Apart fluorescence in situ hybridization (FISH) Probe Kit-is approved for the treatment of ALK positive advanced non-small cell lung cancer (NSCLC). However, the success of a targeted drug is critically dependent on a sensitive and specific screening assay to detect the molecular drug target. In our experience, reverse transcription polymerase chain reaction (RT-PCR)-based detection of EML4-ALK is a more sensitive and reliable approach compared to FISH and immunohistochemistry (IHC). Although ALK FISH is clinically validated, the assay can be technically challenging and other diagnostic modalities, including IHC and RT-PCR should be further explored.

  20. Effect of supplemented intake of omega-3 fatty acids on arrhythmias in patients with ICD: fish oil therapy may reduce ventricular arrhythmia.

    PubMed

    Weisman, Dalit; Beinart, Roy; Erez, Aharon; Koren-Morag, Nira; Goldenberg, Ilan; Eldar, Michael; Glikson, Michael; Luria, David

    2017-09-01

    The aim of this study was to evaluate the effects of fish oils, including eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA), on ventricular tachyarrhythmic episodes (VTEs) in implantable cardioverter defibrillator (ICD) recipients with ischemic cardiomyopathy. One hundred five ICD recipients with ischemic cardiomyopathy received 3.6 g of EPA and DHA and placebo for 6 months, each at a random order, with a 4-month washout period between treatments. Eighty-seven patients completed the 16-month study protocol. The primary end point was any VTE (including sustained and non-sustained ventricular tachycardias at a rate of >150 bpm) as recorded by the ICDs. Secondary end points included device therapy (anti-tachycardia pacing (ATP) or shocks). During treatment with fish oils, there was a significant increase in EPA and DHA concentrations in red blood cells (RBCs) and subcutaneous fat tissue. Among 87 patients who completed the study protocol, the mean number of VTEs was significantly lower during treatment with fish oil (1.7) vs. placebo (5.6; p = 0.035). Appropriate device therapy for VTE occurred in 18 (21%) patients. Fish oil therapy was associated with a trend toward fewer VTEs terminated with ATP (2.8 ± 13.7 vs. 0.5 ± 2.1, respectively; p = 0.077). VTE terminated by ICD shocks, however, was rare, and rates were similar between both groups (0.11 ± 0.6 vs. 0.10 ± 0.4, p = not significant, respectively). Our data suggest that fish oil therapy may be associated with a reduction in the frequency of VTE in ICD recipients with ischemic cardiomyopathy.

  1. Colonisation of fish and crabs of wave energy foundations and the effects of manufactured holes - a field experiment.

    PubMed

    Langhamer, Olivia; Wilhelmsson, Dan

    2009-10-01

    Several Western European countries are planning for a significant development of offshore renewable energy along the European Atlantic Ocean coast, including many thousands of wave energy devices and wind turbines. There is an increasing interest in articulating the added values of the creation of artificial hard bottom habitats through the construction of offshore renewable energy devices, for the benefit of fisheries management and conservation. The Lysekil Project is a test park for wave power located about 100 km north of Gothenburg at the Swedish west coast. A wave energy device consists of a linear wave power generator attached to a foundation on the seabed, and connected by a wire to a buoy at the surface. Our field experiment examined the function of wave energy foundations as artificial reefs. In addition, potentials for enhancing the abundance of associated fish and crustaceans through manufactured holes of the foundations were also investigated. Assemblages of mobile organisms were examined by visual censuses in July and August 2007, 3 months after deployment of the foundations. Results generally show low densities of mobile organisms, but a significantly higher abundance of fish and crabs on the foundations compared to surrounding soft bottoms. Further, while fish numbers were not influenced by increased habitat complexity (holes), it had a significantly positive effect on quantities of edible crab (Cancer pagurus), on average leading to an almost five-fold increase in densities of this species. Densities of spiny starfish (Marthasterias glacialis) were negatively affected by the presence of holes, potentially due to increased predator abundance (e.g. C. pagurus). These results suggest a species-specific response to enhanced habitat complexity.

  2. Design and application of a fish-shaped lateral line probe for flow measurement

    NASA Astrophysics Data System (ADS)

    Tuhtan, J. A.; Fuentes-Pérez, J. F.; Strokina, N.; Toming, G.; Musall, M.; Noack, M.; Kämäräinen, J. K.; Kruusmaa, M.

    2016-04-01

    We introduce the lateral line probe (LLP) as a measurement device for natural flows. Hydraulic surveys in rivers and hydraulic structures are currently based on time-averaged velocity measurements using propellers or acoustic Doppler devices. The long-term goal is thus to develop a sensor system, which includes spatial gradients of the flow field along a fish-shaped sensor body. Interpreting the biological relevance of a collection of point velocity measurements is complicated by the fact that fish and other aquatic vertebrates experience the flow field through highly dynamic fluid-body interactions. To collect body-centric flow data, a bioinspired fish-shaped probe is equipped with a lateral line pressure sensing array, which can be applied both in the laboratory and in the field. Our objective is to introduce a new type of measurement device for body-centric data and compare its output to estimates of conventional point-based technologies. We first provide the calibration workflow for laboratory investigations. We then provide a review of two velocity estimation workflows, independent of calibration. Such workflows are required as existing field investigations consist of measurements in environments where calibration is not feasible. The mean difference for uncalibrated LLP velocity estimates from 0 to 50 cm/s under in a closed flow tunnel and open channel flume was within 4 cm/s when compared to conventional measurement techniques. Finally, spatial flow maps in a scale vertical slot fishway are compared for the LLP, direct measurements, and 3D numerical models where it was found that the LLP provided a slight overestimation of the current velocity in the jet and underestimated the velocity in the recirculation zone.

  3. A cross-sectional evaluation of the validity of a smartphone otoscopy device in screening for ear disease in Nepal.

    PubMed

    Mandavia, R; Lapa, T; Smith, M; Bhutta, M F

    2018-02-01

    Hearing loss is a neglected international health problem. The greatest burden of ear disease is in low-income countries where there is also a lack of resources. In this context, screening for otological disease may be worthwhile. Cupris© has developed an otoscopy device that offers the possibility of low-cost mass screening in remote communities. We evaluated the validity of this device in diagnosing ear disease and in determining whether referral to an ENT centre is warranted. Cross-sectional study. Outpatient clinic, Nepal. All adults and children were invited to take part over a 2-day period. The Cupris© device was used to record participants otological history and examination. Stored history and images were assessed in the United Kingdom by a Consultant-grade ENT Surgeon, who provided a diagnosis and decided whether referral to an ENT centre was warranted. After screening with the Cupris© device, participants were immediately assessed by a UK trained ENT Consultant Surgeon using a standard otoscope ("standard assessment"). A diagnosis was recorded for each participant and a decision was made as to whether referral to an ENT centre was warranted. Concordance in primary diagnosis (analysed per ear) and concordance in the decision to refer (analysed per patient). Cohen's kappa coefficient for inter-rater agreement in diagnosis. Fifty-six patients agreed to participate. In four patients, the quality of video recorded precluded a diagnosis or management plan. These patients were excluded from subsequent analysis, leaving 52 patients for analysis. The same diagnosis was reached for 99 of 104 ears when comparing the Cupris© device to standard assessment (95% concordance), with Cohen's kappa coefficient of 0.89. The decision as to whether a patient should be referred to an ENT centre for further assessment was the same for all 52 participants when comparing the Cupris© device to standard assessment. When compared to standard assessment, the Cupris© device is a valid tool for the diagnosis of ear disease and decision for onward referral. It shows considerable promise for use by trained non-medical workers, as a low-cost and portable tool to screen for ear disease in remote settings, particularly in low- and middle-income countries. © 2017 John Wiley & Sons Ltd.

  4. Performance of handheld electrocardiogram devices to detect atrial fibrillation in a cardiology and geriatric ward setting.

    PubMed

    Desteghe, Lien; Raymaekers, Zina; Lutin, Mark; Vijgen, Johan; Dilling-Boer, Dagmara; Koopman, Pieter; Schurmans, Joris; Vanduynhoven, Philippe; Dendale, Paul; Heidbuchel, Hein

    2017-01-01

    To determine the usability, accuracy, and cost-effectiveness of two handheld single-lead electrocardiogram (ECG) devices for atrial fibrillation (AF) screening in a hospital population with an increased risk for AF. Hospitalized patients (n = 445) at cardiological or geriatric wards were screened for AF by two handheld ECG devices (MyDiagnostick and AliveCor). The performance of the automated algorithm of each device was evaluated against a full 12-lead or 6-lead ECG recording. All ECGs and monitor tracings were also independently reviewed in a blinded fashion by two electrophysiologists. Time investments by nurses and physicians were tracked and used to estimate cost-effectiveness of different screening strategies. Handheld recordings were not possible in 7 and 21.4% of cardiology and geriatric patients, respectively, because they were not able to hold the devices properly. Even after the exclusion of patients with an implanted device, sensitivity and specificity of the automated algorithms were suboptimal (Cardiology: 81.8 and 94.2%, respectively, for MyDiagnostick; 54.5 and 97.5%, respectively, for AliveCor; Geriatrics: 89.5 and 95.7%, respectively, for MyDiagnostick; 78.9 and 97.9%, respectively, for AliveCor). A scenario based on automated AliveCor evaluation in patients without AF history and without an implanted device proved to be the most cost-effective method, with a provider cost to identify one new AF patient of €193 and €82 at cardiology and geriatrics, respectively. The cost to detect one preventable stroke per year would be €7535 and €1916, respectively (based on average CHA 2 DS 2 -VASc of 3.9 ± 2.0 and 5.0 ± 1.5, respectively). Manual interpretation increases sensitivity, but decreases specificity, doubling the cost per detected patient, but remains cheaper than sole 12-lead ECG screening. Using AliveCor or MyDiagnostick handheld recorders requires a structured screening strategy to be effective and cost-effective in a hospital setting. It must exclude patients with implanted devices and known AF, and requires targeted additional 12-lead ECGs to optimize specificity. Under these circumstances, the expenses per diagnosed new AF patient and preventable stroke are reasonable. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  5. Fast-moving soft electronic fish.

    PubMed

    Li, Tiefeng; Li, Guorui; Liang, Yiming; Cheng, Tingyu; Dai, Jing; Yang, Xuxu; Liu, Bangyuan; Zeng, Zedong; Huang, Zhilong; Luo, Yingwu; Xie, Tao; Yang, Wei

    2017-04-01

    Soft robots driven by stimuli-responsive materials have unique advantages over conventional rigid robots, especially in their high adaptability for field exploration and seamless interaction with humans. The grand challenge lies in achieving self-powered soft robots with high mobility, environmental tolerance, and long endurance. We are able to advance a soft electronic fish with a fully integrated onboard system for power and remote control. Without any motor, the fish is driven solely by a soft electroactive structure made of dielectric elastomer and ionically conductive hydrogel. The electronic fish can swim at a speed of 6.4 cm/s (0.69 body length per second), which is much faster than previously reported untethered soft robotic fish driven by soft responsive materials. The fish shows consistent performance in a wide temperature range and permits stealth sailing due to its nearly transparent nature. Furthermore, the fish is robust, as it uses the surrounding water as the electric ground and can operate for 3 hours with one single charge. The design principle can be potentially extended to a variety of flexible devices and soft robots.

  6. Fast-moving soft electronic fish

    PubMed Central

    Li, Tiefeng; Li, Guorui; Liang, Yiming; Cheng, Tingyu; Dai, Jing; Yang, Xuxu; Liu, Bangyuan; Zeng, Zedong; Huang, Zhilong; Luo, Yingwu; Xie, Tao; Yang, Wei

    2017-01-01

    Soft robots driven by stimuli-responsive materials have unique advantages over conventional rigid robots, especially in their high adaptability for field exploration and seamless interaction with humans. The grand challenge lies in achieving self-powered soft robots with high mobility, environmental tolerance, and long endurance. We are able to advance a soft electronic fish with a fully integrated onboard system for power and remote control. Without any motor, the fish is driven solely by a soft electroactive structure made of dielectric elastomer and ionically conductive hydrogel. The electronic fish can swim at a speed of 6.4 cm/s (0.69 body length per second), which is much faster than previously reported untethered soft robotic fish driven by soft responsive materials. The fish shows consistent performance in a wide temperature range and permits stealth sailing due to its nearly transparent nature. Furthermore, the fish is robust, as it uses the surrounding water as the electric ground and can operate for 3 hours with one single charge. The design principle can be potentially extended to a variety of flexible devices and soft robots. PMID:28435879

  7. Infectious hematopoietic necrosis (IHN) and viral hemorrhagic septicemia (VHS): Detection of the trout antibodies to the causative viruses by means of plaque neutralization, immunofluorescence, and enzyme-linked immunosorbent assay

    USGS Publications Warehouse

    Vestergard Jorgensen, P. E.; Olesen, N.J.; Lorenzen, N.; Winton, J.R.; Ristow, S.S.

    1991-01-01

    Sera collected from cultured rainbow trout Oncorhynchus mykiss surviving outbreaks of infectious hematopoietic necrosis (IHN) or viral hemorrhagic septicemia (VHS) were examined for the presence of antibodies to both of the causative viruses, infectious hematopoietic necrosis virus (IHNV) and Egtved virus (viral hemorrhagic septicemia virus: VHSV). Sera were screened with three serological tests: 50% plaque neutralization test (PNT), immunofluorescence (IF), and enzyme-linked immunosorbent assay (ELISA). In sera from 20 rainbow trout surviving IHN, antibodies to IHNV were detected in 9 fish by PNT, in 12 fish by IF, and in 9 fish by ELISA. In these sera, antibodies cross-reacting with VHSV were rare (detected in 0 fish by PNT, in 1 by IF, and in 1 by ELISA). In sera from 20 rainbow trout surviving VHS, antibodies to VHSV were detected in 9 fish by PNT, in 16 fish by IF, and in 18 fish by ELISA. A considerable percentage of the VHS-survivor sera contained antibodies that cross-reacted with IHNV, as detected by ELISA (16 fish) and 1F (7 fish) but not by PNT (0 fish). The three serological tests appear to be useful tools for IHNV and VHSV epidemiology; however, the presence of cross-reacting antibodies in some sera suggests caution when farms require specific pathogen-free certification for one of the viruses in the presence of the other.

  8. Design and Development of an Electrostatic Screen Battery for Emission Control (ESBEC)

    PubMed Central

    Han, Taewon; Mainelis, Gediminas

    2017-01-01

    Current diesel particulate filters (DPFs) can effectively capture the exhaust particles, but they add to engine backpressure and accumulate particles during their operation, which results in the need to regenerate the DPFs by burning off the collected particles periodically. This regeneration results in aerosol emissions, especially in the 10–30 nanometer size range and contributes to ultrafine particle pollution. In this research, we designed and developed a prototype of a novel diesel exhaust control device: the Electrostatic Screen Battery for Emissions Control (ESBEC). The device features high particle collection efficiency without adding to the exhaust backpressure and without the need for thermal regeneration of the collected particles. The ESBEC consists of a series of metal mesh screens coated with a superhydrophobic substance and an integrated carbon fiber ionizer to charge the incoming particles. Multiple pairs of screens (e.g., 5 pairs) are arranged in a battery, in which one screen of each pair is supplied with high voltage, and the other is grounded, producing electrostatic field produced across the screens. The application of a superhydrophobic coating onto the screens allows easy removal of the collected particles using liquid without the need for thermal regeneration. The current prototypes of the device were tested with fluorescent polystyrene latex (PSL) particles of 0.2 and 1.2 μm in size and at 25 and 105 L/min sampling flow rates. The average collection efficiency was ~87% for 0.2 μm and ~95% for 1.2 μm PSL particles. In addition, the ESBEC was tested with actual diesel exhaust particles; here its performance was verified by visually inspecting deposition of particles on an after-filter with the device ON and OFF. In the next stages of this work, the ESBEC will be challenged with diesel exhaust at different mass concentrations and for different collection time periods. PMID:28983124

  9. Design and Development of an Electrostatic Screen Battery for Emission Control (ESBEC).

    PubMed

    Han, Taewon; Mainelis, Gediminas

    2017-05-01

    Current diesel particulate filters (DPFs) can effectively capture the exhaust particles, but they add to engine backpressure and accumulate particles during their operation, which results in the need to regenerate the DPFs by burning off the collected particles periodically. This regeneration results in aerosol emissions, especially in the 10-30 nanometer size range and contributes to ultrafine particle pollution. In this research, we designed and developed a prototype of a novel diesel exhaust control device: the Electrostatic Screen Battery for Emissions Control (ESBEC). The device features high particle collection efficiency without adding to the exhaust backpressure and without the need for thermal regeneration of the collected particles. The ESBEC consists of a series of metal mesh screens coated with a superhydrophobic substance and an integrated carbon fiber ionizer to charge the incoming particles. Multiple pairs of screens (e.g., 5 pairs) are arranged in a battery, in which one screen of each pair is supplied with high voltage, and the other is grounded, producing electrostatic field produced across the screens. The application of a superhydrophobic coating onto the screens allows easy removal of the collected particles using liquid without the need for thermal regeneration. The current prototypes of the device were tested with fluorescent polystyrene latex (PSL) particles of 0.2 and 1.2 μm in size and at 25 and 105 L/min sampling flow rates. The average collection efficiency was ~87% for 0.2 μm and ~95% for 1.2 μm PSL particles. In addition, the ESBEC was tested with actual diesel exhaust particles; here its performance was verified by visually inspecting deposition of particles on an after-filter with the device ON and OFF. In the next stages of this work, the ESBEC will be challenged with diesel exhaust at different mass concentrations and for different collection time periods.

  10. 21 CFR 886.1810 - Tangent screen (campimeter).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tangent screen (campimeter). 886.1810 Section 886.1810 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... a patient's visual field. This generic type of device includes projection tangent screens, target...

  11. 21 CFR 892.1960 - Radiographic intensifying screen.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... (a) Identification. A radiographic intensifying screen is a device that is a thin radiolucent sheet... for medical purposes to expose radiographic film. (b) Classification. Class I (general controls). The...

  12. Estrogen regulation of gene expression in the teleost fish immune system.

    PubMed

    Burgos-Aceves, Mario Alberto; Cohen, Amit; Smith, Yoav; Faggio, Caterina

    2016-11-01

    Elucidating the mechanisms of estrogens-induced immunomodulation in teleost fish is of great importance due to the observed worldwide continuing decrease in pristine environments. However, little is know about the immunotoxicological consequences of exposure to these chemicals in fish, or of the mechanisms through which these effects are mediated. In this review, we summarize the results showing estrogens (natural or synthetic) acting through estrogen receptors and regulating specific target genes, also through microRNAs (miRNAs), leading to modulation of the immune functioning. The identification and characterization of miRNAs will provide new opportunities for functional genome research on teleost immune system and can also be useful when screening for novel molecule biomarkers for environmental pollution. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Electromagnetic radiation screening of semiconductor devices for long life applications

    NASA Technical Reports Server (NTRS)

    Hall, T. C.; Brammer, W. G.

    1972-01-01

    A review is presented of the mechanism of interaction of electromagnetic radiation in various spectral ranges, with various semiconductor device defects. Previous work conducted in this area was analyzed as to its pertinence to the current problem. The task was studied of implementing electromagnetic screening methods in the wavelength region determined to be most effective. Both scanning and flooding type stimulation techniques are discussed. While the scanning technique offers a considerably higher yield of useful information, a preliminary investigation utilizing the flooding approach is first recommended because of the ease of implementation, lower cost and ability to provide go-no-go information in semiconductor screening.

  14. Explosives Detection: Exploitation of the Physical Signatures

    NASA Astrophysics Data System (ADS)

    Atkinson, David

    2010-10-01

    Explosives based terrorism is an ongoing threat that is evolving with respect to implementation, configuration and materials used. There are a variety of devices designed to detect explosive devices, however, each technology has limitations and operational constraints. A full understanding of the signatures available for detection coupled with the array of detection choices can be used to develop a conceptual model of an explosives screening operation. Physics based sensors provide a robust approach to explosives detection, typically through the identification of anomalies, and are currently used for screening in airports around the world. The next generation of detectors for explosives detection will need to be more sensitive and selective, as well as integrate seamlessly with devices focused on chemical signatures. An appreciation for the details of the physical signature exploitation in cluttered environments with time, space, and privacy constraints is necessary for effective explosives screening of people, luggage, cargo, and vehicles.

  15. Estimating fisheries-induced selection: traditional gear selectivity research meets fisheries-induced evolution.

    PubMed

    Kuparinen, Anna; Kuikka, Sakari; Merilä, Juha

    2009-05-01

    The study of fisheries-induced evolution is a research field which is becoming recognized both as an important and interesting problem in applied evolution, as well as a practical management problem in fisheries. Much of the research in fisheries-induced evolution has focussed on quantifying and proving that an evolutionary response has taken place, but less effort has been invested on the actual processes and traits underlying capture of a fish by a fishing gear. This knowledge is not only needed to understand possible phenotypic selection associated to fishing but also to help to device sustainable fisheries and management strategies. Here, we draw attention to the existing knowledge about selectivity of fishing gears and outline the ways in which this information could be utilized in the context of fisheries-induced evolution. To these ends, we will introduce a mathematical framework commonly applied to quantify fishing gear selectivity, illustrate the link between gear selectivity and the change in the distribution of phenotypes induced by fishing, review what is known about selectivity of commonly used fishing gears, and discuss how this knowledge could be applied to improve attempts to predict evolutionary impacts of fishing.

  16. Self-assembled large scale metal alloy grid patterns as flexible transparent conductive layers

    NASA Astrophysics Data System (ADS)

    Mohl, Melinda; Dombovari, Aron; Vajtai, Robert; Ajayan, Pulickel M.; Kordas, Krisztian

    2015-09-01

    The development of scalable synthesis techniques for optically transparent, electrically conductive coatings is in great demand due to the constantly increasing market price and limited resources of indium for indium tin oxide (ITO) materials currently applied in most of the optoelectronic devices. This work pioneers the scalable synthesis of transparent conductive films (TCFs) by exploiting the coffee-ring effect deposition coupled with reactive inkjet printing and subsequent chemical copper plating. Here we report two different promising alternatives to replace ITO, palladium-copper (PdCu) grid patterns and silver-copper (AgCu) fish scale like structures printed on flexible poly(ethylene terephthalate) (PET) substrates, achieving sheet resistance values as low as 8.1 and 4.9 Ω/sq, with corresponding optical transmittance of 79% and 65% at 500 nm, respectively. Both films show excellent adhesion and also preserve their structural integrity and good contact with the substrate for severe bending showing less than 4% decrease of conductivity even after 105 cycles. Transparent conductive films for capacitive touch screens and pixels of microscopic resistive electrodes are demonstrated.

  17. Self-assembled large scale metal alloy grid patterns as flexible transparent conductive layers

    PubMed Central

    Mohl, Melinda; Dombovari, Aron; Vajtai, Robert; Ajayan, Pulickel M.; Kordas, Krisztian

    2015-01-01

    The development of scalable synthesis techniques for optically transparent, electrically conductive coatings is in great demand due to the constantly increasing market price and limited resources of indium for indium tin oxide (ITO) materials currently applied in most of the optoelectronic devices. This work pioneers the scalable synthesis of transparent conductive films (TCFs) by exploiting the coffee-ring effect deposition coupled with reactive inkjet printing and subsequent chemical copper plating. Here we report two different promising alternatives to replace ITO, palladium-copper (PdCu) grid patterns and silver-copper (AgCu) fish scale like structures printed on flexible poly(ethylene terephthalate) (PET) substrates, achieving sheet resistance values as low as 8.1 and 4.9 Ω/sq, with corresponding optical transmittance of 79% and 65% at 500 nm, respectively. Both films show excellent adhesion and also preserve their structural integrity and good contact with the substrate for severe bending showing less than 4% decrease of conductivity even after 105 cycles. Transparent conductive films for capacitive touch screens and pixels of microscopic resistive electrodes are demonstrated. PMID:26333520

  18. Design of a wearable device for real-time screening of urinary tract infection and kidney disease based on smartphone.

    PubMed

    Zhou, Jianyu; Dong, Tao

    2018-06-11

    In this study, we developed a novel wearable and low-cost device for qualitative screening of glucose (GLU), leukocytes (LEU), and nitrite (NIT) and for semi-quantitative analysis of blood (BLD) and proteins (PRO) in the urine samples. The device can be attached to a diaper, and the results can be read by an app. The main functions of the device can be divided into sample collection, valve closing, and pad saturation; the recorded times for valve closing and pad saturation at four corners and pad saturation at the central parts are pseudo-medians (Hodges-Lehmann estimator) of 3.55 (95% WCI, 3.45-3.72), 6.5 (95% WCI, 6-7), and 6 (95% WCI, 5.5-6.5) minutes, respectively. The RGB values in the reagent pads remain stable from 20 min to 480 min, which satisfies the requirement of regular diaper-wearing time. Pre-diagnostic results indicate high accuracy with good accuracy for the app recognition of five biomarkers in the urine samples, which makes it a promising tool for screening diseases, especially for the elderly healthcare.

  19. Identifying changing aviation threat environments within an adaptive Homeland Security Advisory System.

    PubMed

    Lee, Adrian J; Jacobson, Sheldon H

    2012-02-01

    A critical component of aviation security consists of screening passengers and baggage to protect airports and aircraft from terrorist threats. Advancements in screening device technology have increased the ability to detect these threats; however, specifying the operational configurations of these devices in response to changes in the threat environment can become difficult. This article proposes to use Fisher information as a statistical measure for detecting changes in the threat environment. The perceived risk of passengers, according to prescreening information and behavior analysis, is analyzed as the passengers sequentially enter the security checkpoint. The alarm responses from the devices used to detect threats are also analyzed to monitor significant changes in the frequency of threat items uncovered. The key results are that this information-based measure can be used within the Homeland Security Advisory System to indicate changes in threat conditions in real time, and provide the flexibility of security screening detection devices to responsively and automatically adapt operational configurations to these changing threat conditions. © 2012 Society for Risk Analysis. All rights reserved.

  20. AN EVALUATION OF STORM DRAINAGE INLET DEVICES FOR STORMWATER QUALITY TREATMENT

    EPA Science Inventory

    The activities summarized in this paper included the testing of three representative stormwater control devices that were located at storm drainage inlets. The two proprietary devices utilized screening and filtering (using filter fabric and a coarser mesh). A conventional catchb...

  1. VALIDATION OF AN AVIAN TWO-GENERATION REPRODUCTION TEST: U.S. INITIATIVES

    EPA Science Inventory

    Documented effects to fish and wildlife populations, coupled with evidence from human poisonings, epidemiology, and experimental toxicology led to the formation of the Endocrine Disruptor Screening Program (EDSP) within the U.S. Environmental Protection Agency. EDSP main objectiv...

  2. Development of a Nebraska culvert aquatic organism passage screening tool.

    DOT National Transportation Integrated Search

    2012-12-01

    Culverts channelize water relative to natural stream reaches, which can increase the velocity of water passing through them. Increased water velocities can alter stream morphology and create a possible barrier or obstacle to fish passage, which may a...

  3. Influence of a low intensity electric sea lion deterrence system on the migratory behavior of fishes in the upstream migrant tunnel (UMT) at Bonneville Dam.

    USGS Publications Warehouse

    Mesa, Matthew G.; Dixon, Christopher J.

    2010-01-01

    salmonids. As a result, Smith-Root Incorporated (SRI; Vancouver, Washington) proposed a demonstration project to evaluate the potential of an electrical array to deter marine mammals (SRI 2007). The objective of their work was to develop, deploy, and evaluate a passive, integrated electric and sonar array that selectively inhibits upstream marine mammal movements and predation, without injuring pinnipeds or affecting anadromous fish migrations. However, before such a device could be placed in the field, concerns by regional fishery managers about the potential effects of such a device on the migratory behavior of or injury to Pacific salmon, steelhead (O. mykiss), Pacific lampreys (Entoshpenus tridentata), and white sturgeon (Acipenser transmontanus) needed to be addressed.

  4. A survey of wild marine fish identifies a potential origin of an outbreak of viral haemorrhagic septicaemia in wrasse, Labridae, used as cleaner fish on marine Atlantic salmon, Salmo salar L., farms.

    PubMed

    Wallace, I S; Donald, K; Munro, L A; Murray, W; Pert, C C; Stagg, H; Hall, M; Bain, N

    2015-06-01

    Viral haemorrhagic septicaemia virus (VHSV) was isolated from five species of wrasse (Labridae) used as biological controls for parasitic sea lice predominantly, Lepeophtheirus salmonis (Krøyer, 1837), on marine Atlantic salmon, Salmo salar L., farms in Shetland. As part of the epidemiological investigation, 1400 wild marine fish were caught and screened in pools of 10 for VHSV using virus isolation. Eleven pools (8%) were confirmed VHSV positive from: grey gurnard, Eutrigla gurnardus L.; Atlantic herring, Clupea harengus L.; Norway pout, Trisopterus esmarkii (Nilsson); plaice, Pleuronectes platessa L.; sprat, Sprattus sprattus L. and whiting, Merlangius merlangus L. The isolation of VHSV from grey gurnard is the first documented report in this species. Nucleic acid sequencing of the partial nucleocapsid (N) and glycoprotein (G) genes was carried out for viral characterization. Sequence analysis confirmed that all wild isolates were genotype III the same as the wrasse and there was a close genetic similarity between the isolates from wild fish and wrasse on the farms. Infection from these local wild marine fish is the most likely source of VHSV isolated from wrasse on the fish farms. © 2014 Crown Copyright. Journal of Fish Diseases © 2014 John Wiley & Sons Ltd.

  5. Design and characterization of a direct ELISA for the detection and quantification of leucomalachite green

    PubMed Central

    Singh, Gurmit; Koerner, Terence; Gelinas, Jean-Marc; Abbott, Michael; Brady, Beth; Huet, Anne-Catherine; Charlier, Caroline; Delahaut, Philippe; Godefroy, Samuel Benrejeb

    2011-01-01

    Malachite green (MG), a member of the N-methylated triphenylmethane class of dyes, has long been used to control fungal and protozoan infections in fish. MG is easily absorbed by fish during waterborne exposure and is rapidly metabolized into leucomalachite green (LMG), which is known for its long residence time in edible fish tissue. This paper describes the development of an enzyme-linked immunosorbent assay (ELISA) for the detection and quantification of LMG in fish tissue. This development includes a simple and versatile method for the conversion of LMG to monodesmethyl-LMG, which is then conjugated to bovine serum albumin (BSA) to produce an immunogenic material. Rabbit polyclonal antibodies are generated against this immunogen, purified and used to develop a direct competitive enzyme-linked immunosorbent assay (ELISA) for the screening and quantification of LMG in fish tissue. The assay performed well, with a limit of detection (LOD) and limit of quantification (LOQ) of 0.1 and 0.3 ng g−1 of fish tissue, respectively. The average extraction efficiency from a matrix of tilapia fillets was approximately 73% and the day-to-day reproducibility for these extractions in the assay was between 5 and 10%. PMID:21623496

  6. Intestinal microbiota of healthy and unhealthy Atlantic salmon Salmo salar L. in a recirculating aquaculture system

    NASA Astrophysics Data System (ADS)

    Wang, Chun; Sun, Guoxiang; Li, Shuangshuang; Li, Xian; Liu, Ying

    2017-04-01

    The present study sampled the intestinal content of healthy and unhealthy Atlantic salmon (Salmo salar L.), the ambient water of unhealthy fish, and the biofilter material in the recirculating aquaculture system (RAS) to understand differences in the intestinal microbiota. The V4-V5 regions of the prokaryotic 16S rRNA genes in the samples were analyzed by MiSeq high-throughput sequencing. The fish were adults with no differences in body length or weight. Representative members of the intestinal microbiota were identified. The intestinal microbiota of the healthy fish included Proteobacteria (44.33%), Actinobacteria (17.89%), Bacteroidetes (15.25%), and Firmicutes (9.11%), among which the families Micrococcaceae and Oxalobacteraceae and genera Sphingomonas, Streptomyces, Pedobacter, Janthinobacterium, Burkholderia, and Balneimonas were most abundant. Proteobacteria (70.46%), Bacteroidetes (7.59%), and Firmicutes (7.55%) dominated the microbiota of unhealthy fish, and Chloroflexi (2.71%), and Aliivibrio and Vibrio as well as genera in the family Aeromonadaceae were most strongly represented. Overall, the intestinal hindgut microbiota differed between healthy and unhealthy fish. This study offers a useful tool for monitoring the health status of fish and for screening the utility of probiotics by studying the intestinal microbiota.

  7. Intestinal microbiota of healthy and unhealthy Atlantic salmon Salmo salar L. in a recirculating aquaculture system

    NASA Astrophysics Data System (ADS)

    Wang, Chun; Sun, Guoxiang; Li, Shuangshuang; Li, Xian; Liu, Ying

    2018-03-01

    The present study sampled the intestinal content of healthy and unhealthy Atlantic salmon ( Salmo salar L.), the ambient water of unhealthy fish, and the biofilter material in the recirculating aquaculture system (RAS) to understand differences in the intestinal microbiota. The V4-V5 regions of the prokaryotic 16S rRNA genes in the samples were analyzed by MiSeq high-throughput sequencing. The fish were adults with no differences in body length or weight. Representative members of the intestinal microbiota were identified. The intestinal microbiota of the healthy fish included Proteobacteria (44.33%), Actinobacteria (17.89%), Bacteroidetes (15.25%), and Firmicutes (9.11%), among which the families Micrococcaceae and Oxalobacteraceae and genera Sphingomonas, Streptomyces, Pedobacter, Janthinobacterium, Burkholderia, and Balneimonas were most abundant. Proteobacteria (70.46%), Bacteroidetes (7.59%), and Firmicutes (7.55%) dominated the microbiota of unhealthy fish, and Chloroflexi (2.71%), and Aliivibrio and Vibrio as well as genera in the family Aeromonadaceae were most strongly represented. Overall, the intestinal hindgut microbiota differed between healthy and unhealthy fish. This study offers a useful tool for monitoring the health status of fish and for screening the utility of probiotics by studying the intestinal microbiota.

  8. Liquid chromatography with high resolution mass spectrometry for identification of organic contaminants in fish fillet: screening and quantification assessment using two scan modes for data acquisition.

    PubMed

    Munaretto, Juliana S; May, Marília M; Saibt, Nathália; Zanella, Renato

    2016-07-22

    This study proposed a strategy to identify and quantify 182 organic contaminants from different chemical classes, as for instance pesticides, veterinary drug and personal care products, in fish fillet using liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (LC-QToF/MS). For this purpose, two different scan methods (full scan and all ions MS/MS) were evaluated to assess the best option for screening analysis in spiked fish fillet samples. In general, full scan acquisition was found to be more reliable (84%) in the automatic identification and quantification when compared to all ions MS/MS with 72% of the compounds detected. Additionally, a qualitative automatic search showed a mass accuracy error below 5ppm for 77% of the compounds in full scan mode compared to only 52% in all ions MS/MS scan. However, all ions MS/MS provides fragmentation information of the target compounds. Undoubtedly, structural information of a wide number of compounds can be obtained using high resolution mass spectrometry (HRMS), but it is necessary thoroughly assess it, in order to choose the best scan mode. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Dissemination of streptococcal pyrogenic exotoxin G (spegg) with an IS-like element in fish isolates of Streptococcus dysgalactiae.

    PubMed

    Abdelsalam, Mohamed; Chen, Shih-Chu; Yoshida, Terutoyo

    2010-08-01

    The Lancefield group C alpha-hemolytic Streptococcus dysgalactiae ssp. dysgalactiae (GCSD) causes systemic granulomatous inflammatory disease and high mortality rates in infected fish. Superantigen and streptolysin S genes are the most important virulence factors contributing to an invasive streptococcal infection. PCR amplification revealed that all strains isolated from moribund fish harbored the streptolysin S structural gene (sagA). GCSD fish isolates were PCR negative for emm, speA, speB, speC, speM, smeZ, and ssa. However, the size of the streptococcal pyrogenic exotoxin G (spegg) locus, a superantigen, in positive S. dysgalactiae fish and pig strains was variable. The ORF of the spegg locus of 26 GCSD fish strains and one GCSD pig strain was inserted with IS981SC. Interestingly, the ORF of the spegg locus of two fish strains of GCSD collected in Malaysia was inserted with an IS981SC-IS1161 hybrid IS element. The hybrid IS element was found in all of the GCSD fish isolates and one GCSD pig through PCR screening. Although no insertion sequence (IS) was detected in the spegg locus of S. dysgalactiae ssp. equisimilis (GCSE) strains, a five-nucleotide deletion mutation was detected in the ORF of the spegg locus of one GCSE strain at the supposed site of IS981SC insertion, resulting in a frameshift mutation.

  10. Disease resistance is related to inherent swimming performance in Atlantic salmon.

    PubMed

    Castro, Vicente; Grisdale-Helland, Barbara; Jørgensen, Sven M; Helgerud, Jan; Claireaux, Guy; Farrell, Anthony P; Krasnov, Aleksei; Helland, Ståle J; Takle, Harald

    2013-01-21

    Like humans, fish can be classified according to their athletic performance. Sustained exercise training of fish can improve growth and physical capacity, and recent results have documented improved disease resistance in exercised Atlantic salmon. In this study we investigated the effects of inherent swimming performance and exercise training on disease resistance in Atlantic salmon.Atlantic salmon were first classified as either poor or good according to their swimming performance in a screening test and then exercise trained for 10 weeks using one of two constant-velocity or two interval-velocity training regimes for comparison against control trained fish (low speed continuously). Disease resistance was assessed by a viral disease challenge test (infectious pancreatic necrosis) and gene expression analyses of the host response in selected organs. An inherently good swimming performance was associated with improved disease resistance, as good swimmers showed significantly better survival compared to poor swimmers in the viral challenge test. Differences in mortalities between poor and good swimmers were correlated with cardiac mRNA expression of virus responsive genes reflecting the infection status. Although not significant, fish trained at constant-velocity showed a trend towards higher survival than fish trained at either short or long intervals. Finally, only constant training at high intensity had a significant positive effect on fish growth compared to control trained fish. This is the first evidence suggesting that inherent swimming performance is associated with disease resistance in fish.

  11. SCREENING FOR TOXIC INDUSTRIAL CHEMICALS USING SEMIPERMEABLE MEMBRANE DEVICES WITH RAPID TOXICITY ASSAYS

    EPA Science Inventory

    A time-integrated sampling device interfaced with two toxicity-based assays is reported for monitoring volatile toxic industrial chemicals (TICs). Semipermeable membrane devices (SPMDs) using dimethylsulfoxide (DMSO) as the fill solvent accumulated each of 17 TICs from the vapor...

  12. Computer/Mobile Device Screen Time of Children and Their Eye Care Behavior: The Roles of Risk Perception and Parenting.

    PubMed

    Chang, Fong-Ching; Chiu, Chiung-Hui; Chen, Ping-Hung; Miao, Nae-Fang; Chiang, Jeng-Tung; Chuang, Hung-Yi

    2018-03-01

    This study assessed the computer/mobile device screen time and eye care behavior of children and examined the roles of risk perception and parental practices. Data were obtained from a sample of 2,454 child-parent dyads recruited from 30 primary schools in Taipei city and New Taipei city, Taiwan, in 2016. Self-administered questionnaires were collected from students and parents. Fifth-grade students spend more time on new media (computer/smartphone/tablet: 16 hours a week) than on traditional media (television: 10 hours a week). The average daily screen time (3.5 hours) for these children exceeded the American Academy of Pediatrics recommendations (≤2 hours). Multivariate analysis results showed that after controlling for demographic factors, the parents with higher levels of risk perception and parental efficacy were more likely to mediate their child's eye care behavior. Children who reported lower academic performance, who were from non-intact families, reported lower levels of risk perception of mobile device use, had parents who spent more time using computers and mobile devices, and had lower levels of parental mediation were more likely to spend more time using computers and mobile devices; whereas children who reported higher academic performance, higher levels of risk perception, and higher levels of parental mediation were more likely to engage in higher levels of eye care behavior. Risk perception by children and parental practices are associated with the amount of screen time that children regularly engage in and their level of eye care behavior.

  13. Lead Poison Detection

    NASA Technical Reports Server (NTRS)

    1976-01-01

    With NASA contracts, Whittaker Corporations Space Science division has developed an electro-optical instrument to mass screen for lead poisoning. Device is portable and detects protoporphyrin in whole blood. Free corpuscular porphyrins occur as an early effect of lead ingestion. Also detects lead in urine used to confirm blood tests. Test is inexpensive and can be applied by relatively unskilled personnel. Similar Whittaker fluorometry device called "drug screen" can measure morphine and quinine in urine much faster and cheaper than other methods.

  14. Do Handheld Devices Facilitate Face-to-Face Collaboration? Handheld Devices with Large Shared Display Groupware to Facilitate Group Interactions

    ERIC Educational Resources Information Center

    Liu, Chen-Chung; Kao, L.-C.

    2007-01-01

    One-to-one computing environments change and improve classroom dynamics as individual students can bring handheld devices fitted with wireless communication capabilities into the classrooms. However, the screens of handheld devices, being designed for individual-user mobile application, limit promotion of interaction among groups of learners. This…

  15. An integrated microfludic device for culturing and screening of Giardia lamblia.

    PubMed

    Zheng, Guo-Xia; Zhang, Xue-Mei; Yang, Yu-Suo; Zeng, Shu-Rui; Wei, Jun-Feng; Wang, Yun-Hua; Li, Ya-Jie

    2014-02-01

    In vitro culturing of trophozoites was important for research of Giardia lamblia (G. lamblia), especially in discovery of anti-Giardia agents. The current culture methods mainly suffer from lab-intension or the obstacle in standardizing the gas condition. Thus, it could benefit from a more streamlined and integrated approach. Microfluidics offers a way to accomplish this goal. Here we presented an integrated microfluidic device for culturing and screening of G. lamblia. The device consisted of a polydimethylsiloxane (PDMS) microchip with an aerobic culture system. In the microchip, the functionality of integrated concentration gradient generator (CGG) with micro-scale cell culture enables dose-response experiment to be performed in a simple and reagent-saving way. The diffusion-based culture chambers allowed growing G. lamblia at the in vivo like environment. It notable that the highly air permeable material of parallel chambers maintain uniform anaerobic environment in different chambers easily. Using this device, G. lamblia were successfully cultured and stressed on-chip. In all cases, a dose-related inhibitory response was detected. The application of this device for these purposes represents the first step in developing a completely integrated microfluidic platform for high-throughput screening and might be expanded to other assays based on in vitro culture of G. lamblia with further tests. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. Sample-to-answer palm-sized nucleic acid testing device towards low-cost malaria mass screening.

    PubMed

    Choi, Gihoon; Prince, Theodore; Miao, Jun; Cui, Liwang; Guan, Weihua

    2018-05-19

    The effectiveness of malaria screening and treatment highly depends on the low-cost access to the highly sensitive and specific malaria test. We report a real-time fluorescence nucleic acid testing device for malaria field detection with automated and scalable sample preparation capability. The device consists a compact analyzer and a disposable microfluidic reagent compact disc. The parasite DNA sample preparation and subsequent real-time LAMP detection were seamlessly integrated on a single microfluidic compact disc, driven by energy efficient non-centrifuge based magnetic field interactions. Each disc contains four parallel testing units which could be configured either as four identical tests or as four species-specific tests. When configured as species-specific tests, it could identify two of the most life-threatening malaria species (P. falciparum and P. vivax). The NAT device is capable of processing four samples simultaneously within 50 min turnaround time. It achieves a detection limit of ~0.5 parasites/µl for whole blood, sufficient for detecting asymptomatic parasite carriers. The combination of the sensitivity, specificity, cost, and scalable sample preparation suggests the real-time fluorescence LAMP device could be particularly useful for malaria screening in the field settings. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Fluorescence in situ hybridization, immunohistochemistry, and next-generation sequencing for detection of EML4-ALK rearrangement in lung cancer.

    PubMed

    Pekar-Zlotin, Marina; Hirsch, Fred R; Soussan-Gutman, Lior; Ilouze, Maya; Dvir, Addie; Boyle, Theresa; Wynes, Murry; Miller, Vincent A; Lipson, Doron; Palmer, Gary A; Ali, Siraj M; Dekel, Shlomi; Brenner, Ronen; Bunn, Paul A; Peled, Nir

    2015-03-01

    The U.S. Food and Drug Administration-approved method for detecting EML4-ALK rearrangement is fluorescence in situ hybridization (FISH); however, data supporting the use of immunohistochemistry (IHC) for that purpose are accumulating. Previous studies that compared FISH and IHC considered FISH the gold standard, but none compared data with the results of next-generation sequencing (NGS) analysis. We studied FISH and IHC (D5F3 antibody) systematically for EML4-ALK rearrangement in 51 lung adenocarcinoma patients, followed by NGS in case of discordance. Of 51 patients, 4 were positive with FISH (7.8%), and 8 were positive with IHC (15.7%). Three were positive with both. NGS confirmed that four of the five patients who were positive with IHC and negative with FISH were positive for ALK. Two were treated by crizotinib, with progression-free survival of 18 and 6 months. Considering NGS as the most accurate test, the sensitivity and specificity were 42.9% and 97.7%, respectively, for FISH and 100% and 97.7%, respectively, for IHC. The FISH-based method of detecting EML4-ALK rearrangement in lung cancer may miss a significant number of patients who could benefit from targeted ALK therapy. Screening for EML4-ALK rearrangement by IHC should be strongly considered, and NGS is recommended in borderline cases. Two patients who were negative with FISH and positive with IHC were treated with crizotinib and responded to therapy. ©AlphaMed Press.

  18. 75 FR 71428 - Clean River Power 14, LLC; Notice of Preliminary Permit Application Accepted for Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-23

    ...-foot-high reinforced concrete intake structure adjacent to the Martin Creek weir with a trash rack... rack, fish screen, and closure gate; (7) an approximately 0.1-acre impoundment created by the Kelley...

  19. HIGH-THROUGHPUT CHEMICAL SCREENING USING PROTEIN PROFILING OF FISH PLASMA

    EPA Science Inventory

    Compounds that affect the hormone system, referred to as "endocrine-disrupting chemicals" (EDCs), cause human and animal health problems. It is necessary to test putative EDC chemicals for such deleterious effects, though current testing methodologies are time/animal intensive an...

  20. Teleoperated robotic sorting system

    DOEpatents

    Roos, Charles E.; Sommer, Jr., Edward J.; Parrish, Robert H.; Russell, James R.

    2008-06-24

    A method and apparatus are disclosed for classifying materials utilizing a computerized touch sensitive screen or other computerized pointing device for operator identification and electronic marking of spatial coordinates of materials to be extracted. An operator positioned at a computerized touch sensitive screen views electronic images of the mixture of materials to be sorted as they are conveyed past a sensor array which transmits sequences of images of the mixture either directly or through a computer to the touch sensitive display screen. The operator manually "touches" objects displayed on the screen to be extracted from the mixture thereby registering the spatial coordinates of the objects within the computer. The computer then tracks the registered objects as they are conveyed and directs automated devices including mechanical means such as air jets, robotic arms, or other mechanical diverters to extract the registered objects.

  1. Study and design of cryogenic propellant acquisition systems. Volume 2: Supporting experimental program

    NASA Technical Reports Server (NTRS)

    Burge, G. W.; Blackmon, J. B.

    1973-01-01

    Areas of cryogenic fuel systems were identified where critical experimental information was needed either to define a design criteria or to establish the feasibility of a design concept or a critical aspect of a particular design. Such data requirements fell into three broad categories: (1) basic surface tension screen characteristics; (2) screen acquisition device fabrication problems; and (3) screen surface tension device operational failure modes. To explore these problems and to establish design criteria where possible, extensive laboratory or bench test scale experiments were conducted. In general, these proved to be quite successful and, in many instances, the test results were directly used in the system design analyses and development. In some cases, particularly those relating to operational-type problems, areas requiring future research were identified, especially screen heat transfer and vibrational effects.

  2. Teleoperated robotic sorting system

    DOEpatents

    Roos, Charles E.; Sommer, Edward J.; Parrish, Robert H.; Russell, James R.

    2000-01-01

    A method and apparatus are disclosed for classifying materials utilizing a computerized touch sensitive screen or other computerized pointing device for operator identification and electronic marking of spatial coordinates of materials to be extracted. An operator positioned at a computerized touch sensitive screen views electronic images of the mixture of materials to be sorted as they are conveyed past a sensor array which transmits sequences of images of the mixture either directly or through a computer to the touch sensitive display screen. The operator manually "touches" objects displayed on the screen to be extracted from the mixture thereby registering the spatial coordinates of the objects within the computer. The computer then tracks the registered objects as they are conveyed and directs automated devices including mechanical means such as air jets, robotic arms, or other mechanical diverters to extract the registered objects.

  3. High fluid shear strain causes injury in silver shark: Preliminary implications for Mekong hydropower turbine design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baumgartner, L. J.; Thorncraft, G.; Phonekhampheng, O.

    Fluid shear arises when two bodies of water, travelling at different velocities, intersect. Fish entrained at the interface of these two water masses will experience shear stress; which can be harmful. The stress magnitude is dependent on waterbody mass and velocity; with the fish impact largely related to body size. Elevated shear stress occurs where rapidly flowing water passes near spillways, across screens, within turbine draft tubes or other passage routes. A flume was used to determine critical tolerances of silver shark (Balantiocheilos melanopterus) to different shear stress rates generated by a high velocity jet. Fish experienced higher levels ofmore » injury and mortality as shear stress was increased. Excessive shear forces had damaging impacts on fish. Mortality occurred at shear levels higher that 600/s. It is important that developers should attempt to model potential shear profiles expected during turbine passage in selected designs. These data will be critical to determine potential impacts on fish. If the likelihood of adverse impact is high, then alternative designs which have lower shear stress could be explored.« less

  4. High-throughput screening and small animal models, where are we?

    PubMed Central

    Giacomotto, Jean; Ségalat, Laurent

    2010-01-01

    Current high-throughput screening methods for drug discovery rely on the existence of targets. Moreover, most of the hits generated during screenings turn out to be invalid after further testing in animal models. To by-pass these limitations, efforts are now being made to screen chemical libraries on whole animals. One of the most commonly used animal model in biology is the murine model Mus musculus. However, its cost limit its use in large-scale therapeutic screening. In contrast, the nematode Caenorhabditis elegans, the fruit fly Drosophila melanogaster, and the fish Danio rerio are gaining momentum as screening tools. These organisms combine genetic amenability, low cost and culture conditions that are compatible with large-scale screens. Their main advantage is to allow high-throughput screening in a whole-animal context. Moreover, their use is not dependent on the prior identification of a target and permits the selection of compounds with an improved safety profile. This review surveys the versatility of these animal models for drug discovery and discuss the options available at this day. PMID:20423335

  5. One-stop microvascular screening service: an effective model for the early detection of diabetic peripheral neuropathy and the high-risk foot.

    PubMed

    Binns-Hall, O; Selvarajah, D; Sanger, D; Walker, J; Scott, A; Tesfaye, S

    2018-04-02

    To evaluate the feasibility of a one-stop microvascular screening service for the early diagnosis of diabetic distal symmetrical polyneuropathy, painful distal symmetrical polyneuropathy and the at-risk diabetic foot. People with diabetes attending retinal screening in hospital and community settings had their feet examined by a podiatrist. Assessment included: Toronto Clinical Neuropathy Score evaluation; a 10-g monofilament test; and two validated, objective and quick measures of neuropathy obtained using the point-of-care devices 'DPN-Check', a hand-held device that measures sural nerve conduction velocity and amplitude, and 'Sudoscan', a device that measures sudomotor function. The diagnostic utility of these devices was assessed against the Toronto Clinical Neuropathy Score as the 'gold standard'. A total of 236 consecutive people attending the retinal screening service, 18.9% of whom had never previously had their feet examined, were evaluated. The prevalence of distal symmetrical polyneuropathy, assessed using the Toronto Clinical Neuropathy Score, was 30.9%, and was underestimated by 10-g monofilament test (14.4%). The prevalence of distal symmetrical polyneuropathy using DPN-check was 51.5% (84.3% sensitivity, 68.3% specificity), 38.2% using Sudoscan foot electrochemical skin conductance (77.4% sensitivity, 68.3% specificity), and 61.9% using abnormality in either of the results (93.2% sensitivity, 52.8% specificity). The results of both devices correlated with Toronto Clinical Neuropathy Score (P<0.001). A new diagnosis of painful distal symmetrical polyneuropathy was made in 59 participants (25%), and 56.6% had moderate- or high-risk foot. Participants rated the service very highly. Combined, eye, foot and renal screening is feasible, has a high uptake, reduces clinic visits, and identifies painful distal symmetrical polyneuropathy and the at-risk foot. Combined large- and small-nerve-fibre assessment using non-invasive, quantitative and quick point-of-care devices may be an effective model for the early diagnosis of distal symmetrical polyneuropathy. © 2018 The Authors. Diabetic Medicine published by John Wiley & Sons Ltd on behalf of Diabetes UK.

  6. The Role and Design of Screen Images in Software Documentation.

    ERIC Educational Resources Information Center

    van der Meij, Hans

    2000-01-01

    Discussion of learning a new computer software program focuses on how to support the joint handling of a manual, input devices, and screen display. Describes a study that examined three design styles for manuals that included screen images to reduce split-attention problems and discusses theory versus practice and cognitive load theory.…

  7. A Rating Scale to Screen Symptoms of Psychiatric Disorders in Children

    ERIC Educational Resources Information Center

    Scholte, Evert M.; Van Berckelaer-Onnes, Ina; Van der Ploeg, Jan D.

    2008-01-01

    To be able to offer children with developmental disorders adequate help, professionals working in special needs education must use a screening device to assess the specific psychiatric difficulties of the children. In this paper the psychometric properties of an easy-to-use parental rating scale to screen symptoms of major psychiatric disorders…

  8. Application of endocrine disruptor screening program fish short-term reproduction assay: Reproduction and endocrine function in fathead minnow (Pimephales promelas) and killifish (Fundulus heteroclitus) exposed to Bermuda pond sediment.

    PubMed

    Fort, Douglas J; Mathis, Michael; Fort, Chelsea E; Fort, Hayley M; Bacon, Jamie P

    2015-06-01

    A modified tier 1 Endocrine Disruptor Screening Program (EDSP) 21-d fish short-term reproduction assay (FSTRA) was used to evaluate the effects of sediment exposure from freshwater and brackish ponds in Bermuda on reproductive fecundity and endocrine function in fathead minnow (Pimephales promelas) and killifish (Fundulus heteroclitus). Reproductively active male and female fish were exposed to control sediment and sediment from 2 freshwater ponds (fathead minnow) and 2 marine ponds (killifish) contaminated with polyaromatic hydrocarbons and metals via flow-through exposure for 21 d. Reproductive fecundity was monitored daily. At termination, the status of the reproductive endocrine system was assessed by the gonadosomatic index, gonadal histology, plasma steroids (estrogen [E2], testosterone [T], and 11-ketotestosterone [11-KT]), steroidogenic enzymes (aromatase and combined 3β/17β -hydroxysteroid dehydrogenase [3β/17β-HSD]), and plasma vitellogenin (VTG). Decreased reproductive fecundity, lower male body weight, and altered endocrinological measures of reproductive status were observed in both species. Higher plasma T levels in female minnows and 11-KT levels in both male and female minnows and female killifish exposed to freshwater and brackish sediments, respectively. Decreased female E2 and VTG levels and gonadal cytochrome P19 (aromatase) activity were also found in sediment exposed females from both species. No effect on female 3β/17β-HSD activity was found in either species. The FSTRA provided a robust model capable of modification to evaluate reproductive effects of sediment exposure in fish. © 2015 SETAC.

  9. Development of a new screening assay to identify proteratogenic substances using zebrafish danio rerio embryo combined with an exogenous mammalian metabolic activation system (mDarT).

    PubMed

    Busquet, François; Nagel, Roland; von Landenberg, Friedrich; Mueller, Stefan O; Huebler, Nicole; Broschard, Thomas H

    2008-07-01

    The assessment of teratogenic effects of chemicals is generally performed using in vivo teratogenicity assays, for example, in rats or rabbits. We have developed an in vitro teratogenicity assay using the zebrafish Danio rerio embryo combined with an exogenous mammalian metabolic activation system (MAS), able to biotransform proteratogenic compounds. Cyclophosphamide (CPA) and ethanol were used as proteratogens to test the efficiency of this assay. Briefly, the zebrafish embryos were cocultured at 2 hpf (hours postfertilization) with the test material at varying concentrations, induced male rat liver microsomes and nicotinamide adenine dinucleotide phosphate (reduced) for 60 min at 32 degrees C under moderate agitation in Tris-buffer. The negative control (test material alone) and the MAS control (MAS alone) were incubated in parallel. For each test group, 20 eggs were used for statistical robustness. Afterward fish embryos were transferred individually into 24-well plates filled with fish medium for 48 h at 26 degrees C with a 12-h light cycle. Teratogenicity was scored after 24 and 48 hpf using morphological endpoints. No teratogenic effects were observed in fish embryos exposed to the proteratogens alone, that is, without metabolic activation. In contrast, CPA and ethanol induced abnormalities in fish embryos when coincubated with microsomes. The severity of malformations increased with increasing concentrations of the proteratogens. We conclude that the application of microsomes will improve and refine the D. rerio teratogenicity assay as a predictive and valuable alternative method to screen teratogenic substances.

  10. Environmental preferences of tuna and non-tuna species associated with drifting fish aggregating devices (DFADs) in the Atlantic Ocean, ascertained through fishers' echo-sounder buoys

    NASA Astrophysics Data System (ADS)

    Lopez, Jon; Moreno, Gala; Lennert-Cody, Cleridy; Maunder, Mark; Sancristobal, Igor; Caballero, Ainhoa; Dagorn, Laurent

    2017-06-01

    Understanding the relationship between environmental variables and pelagic species concentrations and dynamics is helpful to improve fishery management, especially in a changing environment. Drifting fish aggregating device (DFAD)-associated tuna and non-tuna biomass data from the fishers' echo-sounder buoys operating in the Atlantic Ocean have been modelled as functions of oceanographic (Sea Surface Temperature, Chlorophyll-a, Salinity, Sea Level Anomaly, Thermocline depth and gradient, Geostrophic current, Total Current, Depth) and DFAD variables (DFAD speed, bearing and soak time) using Generalized Additive Mixed Models (GAMMs). Biological interaction (presence of non-tuna species at DFADs) was also included in the tuna model, and found to be significant at this time scale. All variables were included in the analyses but only some of them were highly significant, and variable significance differed among fish groups. In general, most of the fish biomass distribution was explained by the ocean productivity and DFAD-variables. Indeed, this study revealed different environmental preferences for tunas and non-tuna species and suggested the existence of active habitat selection. This improved assessment of environmental and DFAD effects on tuna and non-tuna catchability in the purse seine tuna fishery will contribute to transfer of better scientific advice to regional tuna commissions for the management and conservation of exploited resources.

  11. Touch-screen technology for the dynamic display of -2D spatial information without vision: promise and progress.

    PubMed

    Klatzky, Roberta L; Giudice, Nicholas A; Bennett, Christopher R; Loomis, Jack M

    2014-01-01

    Many developers wish to capitalize on touch-screen technology for developing aids for the blind, particularly by incorporating vibrotactile stimulation to convey patterns on their surfaces, which otherwise are featureless. Our belief is that they will need to take into account basic research on haptic perception in designing these graphics interfaces. We point out constraints and limitations in haptic processing that affect the use of these devices. We also suggest ways to use sound to augment basic information from touch, and we include evaluation data from users of a touch-screen device with vibrotactile and auditory feedback that we have been developing, called a vibro-audio interface.

  12. Fish consumption in pregnancy and omega-3 status after birth are not associated with postnatal depression.

    PubMed

    Browne, Joanna C; Scott, Kate M; Silvers, Karen M

    2006-02-01

    Research to date suggests a relationship between fish consumption, omega-3 polyunsaturated fatty acids, and depression. However, interpretation of this research is difficult due to methodological limitations. Postpartum women provide an excellent opportunity to examine these relationships because omega-3s are transferred from mother to fetus during pregnancy and from mother to child after birth through breast milk. Hence new mothers are more likely to be depleted in omega-3s. Our aim was to determine whether prenatal fish consumption and omega-3 status after birth were associated with postnatal depression. Eighty first-time mothers were recruited; 41 who scored on or over the cut-off on one of two depression-screening instruments, and 39 in the control group. Depression was diagnosed using the Composite International Diagnostic Interview. Fish consumption was measured during pregnancy, and depression and omega-3 status were determined postnatally. Logistic regression and t-tests were used to examine relationships between fish consumption, omega-3 status, and postnatal depression, while controlling for known covariates. Prenatal fish consumption was not predictive of postnatal depression, and postnatal omega-3 status was not associated with postnatal depression. However, prenatal fish consumption did predict omega-3 status after birth. Prenatal fish consumption was measured using only a food frequency questionnaire, and no participants consumed oily fish (rich in omega-3s) regularly. There was no association between postnatal depression and either fish consumption in early pregnancy, or omega-3 status after birth. Our findings make it difficult to justify trials of omega-3 polyunsaturated fatty acids in the treatment of postnatal depression.

  13. Additive manufacturing of lab-on-a-chip devices: promises and challenges

    NASA Astrophysics Data System (ADS)

    Zhu, Feng; Macdonald, Niall P.; Cooper, Jonathan M.; Wlodkowic, Donald

    2013-12-01

    This work describes a preliminary investigation of commercially available 3D printing technologies for rapid prototyping and low volume fabrication of Lab-on-a-Chip devices. The main motivation of the work was to use off-the-shelf 3D printing methods in order to rapidly and inexpensively build microfluidic devices with complex geometric features and reduce the need to use clear room environment and conventional microfabrication techniques. Both multi-jet modelling (MJM) and stereolithography (SLA) processes were explored. MJM printed devices were fabricated using a HD3500+ (3D Systems) high-definition printer using a thermo-polymer VisiJet Crystal (3D Systems) substratum that allows for a z-axis resolution of 16 μm and 25 μm x-y accuracy. SLA printed devices were produced using a Viper Pro (3D Systems) stereolithography system using Watershed 11122XC (DSM Somos) and Dreve Fototec 7150 Clear (Dreve Otoplastik GmbH) resins which allow for a z-axis resolution of 50 μm and 25 μm x-y accuracy. Fabrication results compared favourably with other forms of rapid prototyping such as laser cut PMMA devices and PDMS moulded microfluidic devices of the same design. Both processes allowed for fabrication of monolithic, optically transparent devices with features in the 100 μm range requiring minimal post-processing. Optical polymer qualities following different post-processing methods were also tested in both brightfield and fluorescence imaging of transgenic zebrafish embryos. Finally, we show that only ethanol-treated Dreve Fototec 7150 Clear resign proved to be non-toxic to human cell lines and fish embryos in fish toxicity assays (FET) requiring further investigation of 3D printing materials.

  14. Hydrodynamic model of screen channel liquid acquisition devices for in-space cryogenic propellant management

    NASA Astrophysics Data System (ADS)

    Darr, S. R.; Camarotti, C. F.; Hartwig, J. W.; Chung, J. N.

    2017-01-01

    Technologies that enable the storage and transfer of cryogenic propellants in space will be needed for the next generation vehicles that will carry humans to Mars. One of the candidate technologies is the screen channel liquid acquisition device (LAD), which uses a metal woven wire mesh to separate the liquid and vapor phases so that single-phase liquid propellant can be transferred in microgravity. In this work, an experiment is carried out that provides measurements of the velocity and pressure fields in a screen channel LAD. These data are used to validate a new analytical solution of the liquid flow through a screen channel LAD. This hydrodynamic model, which accounts for non-uniform injection through the screen, is compared with the traditional pressure term summation model which assumes a constant, uniform injection velocity. Results show that the new model performs best against the new data and historical data. The velocity measurements inside the screen channel LAD are used to provide a more accurate velocity profile which further improves the new model. The result of this work is a predictive tool that will instill confidence in the design of screen channel LADs for future in-space propulsion systems.

  15. Recent Progress in Biomimetic Flow Control

    DTIC Science & Technology

    2014-09-19

    trailing-edge, and wing surface devices, respectively. 2 Leading-edge devices Among various marine animals, the humpback whale is one of the... whale : a humpback whale (left) and the detailed view of a pectoral flipper (right). Photographs: William Rossitier. Figure 2: Variation of the lift...Fish, F. E. (2004), Leading-edge tubercles delay stall on humpback whale (Megaptera novaeanglieae) flippers, Phys. Fluids, Vol. 16, L39-L42

  16. Increased metal concentrations in exhaled breath condensate of industrial welders.

    PubMed

    Hoffmeyer, Frank; Weiss, Tobias; Lehnert, Martin; Pesch, Beate; Berresheim, Hans; Henry, Jana; Raulf-Heimsoth, Monika; Broding, Horst Christoph; Bünger, Jürgen; Harth, Volker; Brüning, Thomas

    2011-01-01

    It was the aim of this study to evaluate the effect of different devices on the metal concentration in exhaled breath condensate (EBC) and to prove whether working conditions in different welding companies result in diverse composition of metallic elements. The influence of two collection devices (ECoScreen, ECoScreen2) on detection of metallic elements in EBC was evaluated in 24 control subjects. Properties of ECoScreen and a frequent use can alter EBC metal content due to contamination from metallic components. ECoScreen2 turned out to be favourable for metal assessment. Concentrations of iron, nickel and chromium in EBC sampled with ECoScreen2 were compared between non-exposed controls and industrial welders. Metal concentrations in EBC were higher in 36 welders recruited from three companies. Exposure to welding fumes could be demonstrated predominantly for increased iron concentrations. Concentrations of iron and nickel differed by working conditions, but chromium could not be detected in EBC.

  17. e-Screening revolution: A novel approach to developing a delirium screening tool in the intensive care unit.

    PubMed

    Eeles, Eamonn; Gunn, Hayley; Sutt, Anna-Liisa; Pinsker, Donna; Flaws, Dylan; Jarrett, Paul; Lye, India; Fraser, John F

    2018-06-01

    Delirium is common in the intensive care unit (ICU), often affecting older patients. A bedside electronic tool has the potential to revolutionise delirium screening. Our group describe a novel approach to the design and development of delirium screening questions for the express purpose of use within an electronic device. Preliminary results are presented. Our group designed a series of tests which targeted the clinical criteria for delirium according to Diagnostic and Statistical Manual of Mental Disorders - Fifth Edition (DSM-5) criteria against predefined requirements, including applicability to older patients. Candidate questions, including tests of attention and awareness, were devised and then refined by an expert multidisciplinary group, including geriatricians. A scoring scheme was constructed, with testing to failure an indicator of delirium. The device was tested in healthy controls, aged 20-80 years, who were recorded as being without delirium. e-Screening for delirium requires a novel approach to instrument design but may revolutionise recognition of delirium in ICU. © 2018 AJA Inc.

  18. The effects of sampling location and turbulence on discharge estimates in short converging turbine intakes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Romero-Gomez, P.; Harding, S. F.; Richmond, M. C.

    2017-01-01

    Standards provide recommendations for best practices when installing current meters to measure fluid flow in closed conduits. A central guideline requires the velocity distribution to be regular and the flow steady. Because of the nature of the short converging intakes typical of low-head hydroturbines, these assumptions may be invalid if current meters are intended to be used to estimate discharge. Usual concerns are (1) the effects of the number of devices, (2) the sampling location and (3) the high turbulence caused by blockage from submersible traveling screens usually deployed for safe downstream fish passage. These three effects were examined inmore » the present study by using 3D simulated flow fields in both steady-state and transient modes. In the process of describing an application at an existing hydroturbine intake at Ice Harbor Dam, the present work outlined the methods involved, which combined computational fluid dynamics, laboratory measurements in physical models of the hydroturbine, and current meter performance evaluations in experimental settings. The main conclusions in this specific application were that a steady-state flow field sufficed to determine the adequate number of meters and their location, and that both the transverse velocity and turbulence intensity had a small impact on estimate errors. However, while it may not be possible to extrapolate these findings to other field conditions and measuring devices, the study laid out a path to conduct similar assessments in other applications.« less

  19. Improved intensifying screen reduces X-ray exposure

    NASA Technical Reports Server (NTRS)

    Buchanan, R. A.

    1972-01-01

    X-ray intensifying screen may make possible radiographic procedures where detection speed and X-ray tube power have been the limiting factors. Device will reduce total population exposure to harmful radiation in the United States.

  20. Analysis of field usage failure rate data for plastic encapsulated solid state devices

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Survey and questionnaire techniques were used to gather data from users and manufacturers on the failure rates in the field of plastic encapsulated semiconductors. It was found that such solid state devices are being successfully used by commercial companies which impose certain screening and qualification procedures. The reliability of these semiconductors is now adequate to support their consideration in NASA systems, particularly in low cost systems. The cost of performing necessary screening for NASA applications was assessed.

  1. Protective laser beam viewing device

    DOEpatents

    Neil, George R.; Jordan, Kevin Carl

    2012-12-18

    A protective laser beam viewing system or device including a camera selectively sensitive to laser light wavelengths and a viewing screen receiving images from the laser sensitive camera. According to a preferred embodiment of the invention, the camera is worn on the head of the user or incorporated into a goggle-type viewing display so that it is always aimed at the area of viewing interest to the user and the viewing screen is incorporated into a video display worn as goggles over the eyes of the user.

  2. High-performance and flexible thermoelectric films by screen printing solution-processed nanoplate crystals.

    PubMed

    Varghese, Tony; Hollar, Courtney; Richardson, Joseph; Kempf, Nicholas; Han, Chao; Gamarachchi, Pasindu; Estrada, David; Mehta, Rutvik J; Zhang, Yanliang

    2016-09-12

    Screen printing allows for direct conversion of thermoelectric nanocrystals into flexible energy harvesters and coolers. However, obtaining flexible thermoelectric materials with high figure of merit ZT through printing is an exacting challenge due to the difficulties to synthesize high-performance thermoelectric inks and the poor density and electrical conductivity of the printed films. Here, we demonstrate high-performance flexible films and devices by screen printing bismuth telluride based nanocrystal inks synthesized using a microwave-stimulated wet-chemical method. Thermoelectric films of several tens of microns thickness were screen printed onto a flexible polyimide substrate followed by cold compaction and sintering. The n-type films demonstrate a peak ZT of 0.43 along with superior flexibility, which is among the highest reported ZT values in flexible thermoelectric materials. A flexible thermoelectric device fabricated using the printed films produces a high power density of 4.1 mW/cm(2) with 60 °C temperature difference between the hot side and cold side. The highly scalable and low cost process to fabricate flexible thermoelectric materials and devices demonstrated here opens up many opportunities to transform thermoelectric energy harvesting and cooling applications.

  3. High-performance and flexible thermoelectric films by screen printing solution-processed nanoplate crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Varghese, Tony; Hollar, Courtney; Richardson, Joseph

    Screen printing allows for direct conversion of thermoelectric nanocrystals into flexible energy harvesters and coolers. However, obtaining flexible thermoelectric materials with high figure of merit ZT through printing is an exacting challenge due to the difficulties to synthesize high-performance thermoelectric inks and the poor density and electrical conductivity of the printed films. Here, we demonstrate high-performance flexible films and devices by screen printing bismuth telluride based nanocrystal inks synthesized using a microwave-stimulated wet-chemical method. Thermoelectric films of several tens of microns thickness were screen printed onto a flexible polyimide substrate followed by cold compaction and sintering. The n-type films demonstratemore » a peak ZT of 0.43 along with superior flexibility, which is among the highest reported ZT values in flexible thermoelectric materials. A flexible thermoelectric device fabricated using the printed films produces a high power density of 4.1 mW/cm 2 with 60°C temperature difference between the hot side and cold side. In conclusion, the highly scalable and low cost process to fabricate flexible thermoelectric materials and devices demonstrated here opens up many opportunities to transform thermoelectric energy harvesting and cooling applications.« less

  4. Microfluidic Devices for Drug Delivery Systems and Drug Screening

    PubMed Central

    Kompella, Uday B.; Damiati, Safa A.

    2018-01-01

    Microfluidic devices present unique advantages for the development of efficient drug carrier particles, cell-free protein synthesis systems, and rapid techniques for direct drug screening. Compared to bulk methods, by efficiently controlling the geometries of the fabricated chip and the flow rates of multiphase fluids, microfluidic technology enables the generation of highly stable, uniform, monodispersed particles with higher encapsulation efficiency. Since the existing preclinical models are inefficient drug screens for predicting clinical outcomes, microfluidic platforms might offer a more rapid and cost-effective alternative. Compared to 2D cell culture systems and in vivo animal models, microfluidic 3D platforms mimic the in vivo cell systems in a simple, inexpensive manner, which allows high throughput and multiplexed drug screening at the cell, organ, and whole-body levels. In this review, the generation of appropriate drug or gene carriers including different particle types using different configurations of microfluidic devices is highlighted. Additionally, this paper discusses the emergence of fabricated microfluidic cell-free protein synthesis systems for potential use at point of care as well as cell-, organ-, and human-on-a-chip models as smart, sensitive, and reproducible platforms, allowing the investigation of the effects of drugs under conditions imitating the biological system. PMID:29462948

  5. High-performance and flexible thermoelectric films by screen printing solution-processed nanoplate crystals

    DOE PAGES

    Varghese, Tony; Hollar, Courtney; Richardson, Joseph; ...

    2016-09-12

    Screen printing allows for direct conversion of thermoelectric nanocrystals into flexible energy harvesters and coolers. However, obtaining flexible thermoelectric materials with high figure of merit ZT through printing is an exacting challenge due to the difficulties to synthesize high-performance thermoelectric inks and the poor density and electrical conductivity of the printed films. Here, we demonstrate high-performance flexible films and devices by screen printing bismuth telluride based nanocrystal inks synthesized using a microwave-stimulated wet-chemical method. Thermoelectric films of several tens of microns thickness were screen printed onto a flexible polyimide substrate followed by cold compaction and sintering. The n-type films demonstratemore » a peak ZT of 0.43 along with superior flexibility, which is among the highest reported ZT values in flexible thermoelectric materials. A flexible thermoelectric device fabricated using the printed films produces a high power density of 4.1 mW/cm 2 with 60°C temperature difference between the hot side and cold side. In conclusion, the highly scalable and low cost process to fabricate flexible thermoelectric materials and devices demonstrated here opens up many opportunities to transform thermoelectric energy harvesting and cooling applications.« less

  6. High-performance and flexible thermoelectric films by screen printing solution-processed nanoplate crystals

    PubMed Central

    Varghese, Tony; Hollar, Courtney; Richardson, Joseph; Kempf, Nicholas; Han, Chao; Gamarachchi, Pasindu; Estrada, David; Mehta, Rutvik J.; Zhang, Yanliang

    2016-01-01

    Screen printing allows for direct conversion of thermoelectric nanocrystals into flexible energy harvesters and coolers. However, obtaining flexible thermoelectric materials with high figure of merit ZT through printing is an exacting challenge due to the difficulties to synthesize high-performance thermoelectric inks and the poor density and electrical conductivity of the printed films. Here, we demonstrate high-performance flexible films and devices by screen printing bismuth telluride based nanocrystal inks synthesized using a microwave-stimulated wet-chemical method. Thermoelectric films of several tens of microns thickness were screen printed onto a flexible polyimide substrate followed by cold compaction and sintering. The n-type films demonstrate a peak ZT of 0.43 along with superior flexibility, which is among the highest reported ZT values in flexible thermoelectric materials. A flexible thermoelectric device fabricated using the printed films produces a high power density of 4.1 mW/cm2 with 60 °C temperature difference between the hot side and cold side. The highly scalable and low cost process to fabricate flexible thermoelectric materials and devices demonstrated here opens up many opportunities to transform thermoelectric energy harvesting and cooling applications. PMID:27615036

  7. Study of AUTO-LION (Automatic Lighting Rumpon) on Fisheries of Stationary Lift Net in Semarang, Central Java

    NASA Astrophysics Data System (ADS)

    Chairunnisa, S.; Setiawan, N.; Irkham; Ekawati, K.; Anwar, A.; Fitri, A. DP

    2018-02-01

    Fish Aggregation Device (FAD) is a fishing tool that serves to collect fish at a place to facilitate fishermen in the process of fishing. The use of light is also proven to help the process of fishing at night. AUTO-LION (Automatic Lighting Rumpon) is a FADs innovation equipped with fish-eating sound and solar-powered lights that can be activated automatically when it is dark or nighttime.The purpose of this study was to determine the effect of AUTO-LION use on fishermen catch. The research method used is experimental fishing.The research was conducted on May 2017 on the stationary lift net in Semarang Waters. The results showed the catch as much as 10.55 kg without the use of AUTO-LION, 15.05 kg on the use of FADs, 19.08 kg on the use of FADs with sound, 27.04 kg on the use of FADs with light, and 40.01 kg on the use of AUTO-LION. Based on these results it can be seen that the use of AUTO-LION can increase the catch of fishermen, especially when the light is activated.

  8. Signal Cloaking by Electric Fish

    PubMed Central

    STODDARD, PHILIP K.; MARKHAM, MICHAEL R.

    2010-01-01

    Electric fish produce weak electric fields to image their world in darkness and to communicate with potential mates and rivals. Eavesdropping by electroreceptive predators exerts selective pressure on electric fish to shift their signals into less-detectable high-frequency spectral ranges. Hypopomid electric fish evolved a signal-cloaking strategy that reduces their detectability by predators in the lab (and thus presumably their risk of predation in the field). These fish produce broad-frequency electric fields close to the body, but the heterogeneous local fields merge over space to cancel the low-frequency spectrum at a distance. Mature males dynamically regulate this cloaking mechanism to enhance or suppress low-frequency energy. The mechanism underlying electric-field cloaking involves electrogenic cells that produce two independent action potentials. In a unique twist, these cells orient sodium and potassium currents in the same direction, potentially boosting their capabilities for current generation. Exploration of such evolutionary inventions could aid the design of biogenerators to power implantable medical devices, an ambition that would benefit from the complete genome sequence of a gymnotiform fish. PMID:20209064

  9. Metal current collect protected by oxide film

    DOEpatents

    Jacobson, Craig P.; Visco, Steven J.; DeJonghe, Lutgard C.

    2004-05-25

    Provided are low-cost, mechanically strong, highly electronically conductive current collects and associated structures for solid-state electrochemical devices, techniques for forming these structures, and devices incorporating the structures. The invention provides solid state electrochemical devices having as current interconnects a ferritic steel felt or screen coated with a protective oxide film.

  10. 76 FR 27331 - Draft Guidance for Industry and Food and Drug Administration Staff; Establishing the Performance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-11

    ... Characteristics of In Vitro Diagnostic Devices for Chlamydia Trachomatis and/or Neisseria Gonorrhoeae: Screening... entitled ``Establishing the Performance Characteristics of In Vitro Diagnostic Devices for Chlamydia... clinical performance of in vitro diagnostic devices (IVDs) intended for C. trachomatis and/or N...

  11. Evaluation of portable breath test devices for screening suspected drunken drivers by police in Hennepin County, Minnesota

    DOT National Transportation Integrated Search

    1974-06-01

    This evaluation report examines use in the field of portable breath test (PBT) devices by police in Hennepin County, Minnesota. Thirteen Brog-Warner J2 and J2A-200 "ALERT" devices were deployed by seven enforcement agencies. This report is presented ...

  12. 47. View of beginning of unlined canal from MundyLoss bridge ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    47. View of beginning of unlined canal from Mundy-Loss bridge downstream from fish screens, looking west. Photo by Robin Lee Tedder, Puget Power, 1989. - Puget Sound Power & Light Company, White River Hydroelectric Project, 600 North River Avenue, Dieringer, Pierce County, WA

  13. 78 FR 16500 - Environmental Impacts Statements; Notice of Availability

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-15

    ... and Vegetation Management Project, Comment Period Ends: 04/29/2013, Contact: Marcy Anderson 541-419-0517. EIS No. 20130062, Draft EIS, USFS, NM, Roca Honda Mine Project, Exploration and Mine Development... Seco Riparian Sanctuary Unit Restoration and Pumping Plant/Fish Screen Facility Protection Project...

  14. Characterizing Exposures of Fish to Wastewater Treatment Plant Effluent: An Integrated Metabolite and Lipid Profiling Approach

    EPA Science Inventory

    Metabolite and lipid profiling are well established techniques for studying chemical-induced alterations to normal biological function in numerous organisms. These techniques have been used successfully to identify biomarkers of chemical exposure, screen for chemical potency, or ...

  15. Antenatal diagnosis of Down syndrome: how good is state of the art.

    PubMed

    Mittal, Riju; Varghese, Raji Mathew; Puliyel, Jacob M

    2009-01-01

    A newborn with Down syndrome can be expected once in a thousand deliveries. Amniocentesis for karyotyping of foetal cells or detection of foetal cell in the maternal circulation ie, fluorescent in-situ hybridisation (FISH) and karyotyping, are definitive methods of making the diagnosis antenatally. The cost of doing this routinely in all pregnancies is prohibitive. This has led to dependence on screening tests, to select women more likely to be carrying a Down foetus, to offer karyotyping in a more cost efficient manner. Unfortunately, these screening criteria, namely maternal age, biochemical markers and ultrasound pointers, are rather insensitive and miss a large number of cases of Down syndrome. At the same time they are very non-specific, picking up a large number of false positive cases, resulting in undue anxiety and unnecessary alarm in a large number of mothers. Till a non-invasive, definitive test, like FISH can be routinely used in all pregnancies at affordable costs, accurate antenatal diagnosis on a community basis will be a hit and miss affair.

  16. Laboratory Experiments on the Effects of Blade Strike from Hydrokinetic Energy Technologies on Larval and Juvenile Freshwater Fishes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schweizer, Peter E; Cada, Glenn F; Bevelhimer, Mark S

    2012-03-01

    There is considerable interest in the development of marine and hydrokinetic energy projects in rivers, estuaries, and coastal ocean waters of the United States. Hydrokinetic (HK) technologies convert the energy of moving water in river or tidal currents into electricity, without the impacts of dams and impoundments associated with conventional hydropower or the extraction and combustion of fossil fuels. The Federal Energy Regulatory Commission (FERC) maintains a database that displays the geographical distribution of proposed HK projects in inland and tidal waters (FERC 2012). As of March 2012, 77 preliminary permits had been issued to private developers to study HKmore » projects in inland waters, the development of which would total over 8,000 MW. Most of these projects are proposed for the lower Mississippi River. In addition, the issuance of another 27 preliminary permits for HK projects in inland waters, and 3 preliminary permits for HK tidal projects (totaling over 3,100 MW) were under consideration by FERC. Although numerous HK designs are under development (see DOE 2009 for a description of the technologies and their potential environmental effects), the most commonly proposed current-based projects entail arrays of rotating devices, much like submerged wind turbines, that are positioned in the high-velocity (high energy) river channels. The many diverse HK designs imply a diversity of environmental impacts, but a potential impact common to most is the risk for blade strike to aquatic organisms. In conventional hydropower generation, research on fish passage through reaction turbines at low-head dams suggested that strike and mortality for small fish could be low. As a consequence of the large surface area to mass ratio of small fish, the drag forces in the boundary layer flow at the surface of a rotor blade may pull small fish around the leading edge of a rotor blade without making physical contact (Turnpenny 1998, Turnpenny et al. 2000). Although there is concern that small, fragile fish early life stages may be unable to avoid being struck by the blades of hydrokinetic turbines, we found no empirical data in the published literature that document survival of earliest life-stage fish in passage by rotor blades. In addition to blade strike, research on passage of fish through conventional hydropower turbines suggested that fish mortalities from passage through the rotor swept area could also occur due to shear stresses and pressure chances in the water column (Cada et al. 1997, Turnpenny 1998). However, for most of the proposed HK turbine designs the rotors are projected to operate a lower RPM (revolutions per minute) than observed from conventional reaction turbines; the associated shear stress and pressure changes are expected to be lower and pose a smaller threat to fish survival (DOE 2009). Only a limited number of studies have been conducted to examine the risk of blade strike from hydrokinetic technologies to fish (Turnpenny et al. 1992, Normandeau et al. 2009, Seitz et al. 2011, EPRI 2011); the survival of drifting or weakly swimming fish (especially early life stages) that encounter rotor blades from hydrokinetic (HK) devices is currently unknown. Our study addressed this knowledge gap by testing how fish larvae and juveniles encountered different blade profiles of hydrokinetic devices and how such encounters influenced survivorship. We carried out a laboratory study designed to improve our understanding of how fish larvae and juvenile fish may be affected by encounters with rotor blades from HK turbines in the water column of river and ocean currents. (For convenience, these early life stages will be referred to as young of the year, YOY). The experiments developed information needed to quantify the risk (both probability and consequences) of rotor-blade strike to YOY fish. In particular, this study attempted to determine whether YOY drifting in a high-velocity flow directly in the path of the blade leading edge will make contact with the rotor blade or will bypass the blade while entrained in the boundary layer of water flowing over the blade surface. The study quantified both immediate and delayed mortalities (observed immediately, 3 hours, and 24 hours after encountering the blade) among freshwater YOY fish resulting from contact with the blade or turbulent flows in the wake of the blade.« less

  17. Novel LTCC-potentiometric microfluidic device for biparametric analysis of organic compounds carrying plastic antibodies as ionophores: application to sulfamethoxazole and trimethoprim.

    PubMed

    Almeida, S A A; Arasa, E; Puyol, M; Martinez-Cisneros, C S; Alonso-Chamarro, J; Montenegro, M C B S M; Sales, M G F

    2011-12-15

    Monitoring organic environmental contaminants is of crucial importance to ensure public health. This requires simple, portable and robust devices to carry out on-site analysis. For this purpose, a low-temperature co-fired ceramics (LTCC) microfluidic potentiometric device (LTCC/μPOT) was developed for the first time for an organic compound: sulfamethoxazole (SMX). Sensory materials relied on newly designed plastic antibodies. Sol-gel, self-assembling monolayer and molecular-imprinting techniques were merged for this purpose. Silica beads were amine-modified and linked to SMX via glutaraldehyde modification. Condensation polymerization was conducted around SMX to fill the vacant spaces. SMX was removed after, leaving behind imprinted sites of complementary shape. The obtained particles were used as ionophores in plasticized PVC membranes. The most suitable membrane composition was selected in steady-state assays. Its suitability to flow analysis was verified in flow-injection studies with regular tubular electrodes. The LTCC/μPOT device integrated a bidimensional mixer, an embedded reference electrode based on Ag/AgCl and an Ag-based contact screen-printed under a micromachined cavity of 600 μm depth. The sensing membranes were deposited over this contact and acted as indicating electrodes. Under optimum conditions, the SMX sensor displayed slopes of about -58.7 mV/decade in a range from 12.7 to 250 μg/mL, providing a detection limit of 3.85 μg/mL and a sampling throughput of 36 samples/h with a reagent consumption of 3.3 mL per sample. The system was adjusted later to multiple analyte detection by including a second potentiometric cell on the LTCC/μPOT device. No additional reference electrode was required. This concept was applied to Trimethoprim (TMP), always administered concomitantly with sulphonamide drugs, and tested in fish-farming waters. The biparametric microanalyzer displayed Nernstian behaviour, with average slopes -54.7 (SMX) and +57.8 (TMP) mV/decade. To demonstrate the microanalyzer capabilities for real applications, it was successfully applied to single and simultaneous determination of SMX and TMP in aquaculture waters. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Morphological and molecular characterization of a marine fish trypanosome from South Africa, including its development in a leech vector.

    PubMed

    Hayes, Polly M; Lawton, Scott P; Smit, Nico J; Gibson, Wendy C; Davies, Angela J

    2014-01-24

    Trypanosomes are ubiquitous blood parasites of marine and freshwater fishes, typically transmitted by aquatic leeches. Phylogenetic studies have been dominated by examples derived from freshwater fishes, with few marine representatives. Furthermore, life cycle studies on marine fish trypanosomes have focused on those of the northern hemisphere. In this investigation, we have examined the life cycle and molecular taxonomy of a marine fish trypanosome from South Africa. To locate trypanosome stages, leeches were removed from fishes captured on the west and south coasts of South Africa, and fish blood films and leech squashes were Giemsa-stained and screened; leeches were also examined histologically. To determine whether trypanosome stages in fishes and leeches were of the same genotype, DNA was extracted from Giemsa-stained fish blood films and leech squashes, and from fish whole blood. Fragments of the 18S rRNA gene were amplified by PCR using trypanosome-specific primers and sequenced. Resulting sequence data were compared with each other and with published trypanosome 18S rDNA sequences, and used for phylogenetic analysis. Trypanosomes were detected in blood films from fishes of the families Clinidae, Blenniidae and Gobiidae. The flagellates ranged in size and staining properties within the films and across fish hosts. In squashes and histological sections of adult and juvenile leeches, identified as Zeylanicobdella arugamensis, trypanosome developmental stages were predominantly slender epimastigotes. Sequence data showed that trypanosomes derived from fishes were identical, irrespective of whether they were small or large forms; sequences derived largely from leech epimastigotes were also identical to those obtained from fish trypanosomes. Fish and leech trypanosome sequences fell into a marine fish aquatic clade, and aligned most closely with two trypanosome sequences from marine fishes off Norway. Combined morphological and molecular methods indicate that the trypanosomes examined here represent a single pleomorphic species, rather than the three species described originally. This species is identified as Trypanosoma nudigobii Fantham, 1919 with the leech Z. arugamensis as its vector, and T. capigobii Fantham, 1919 and T. blenniclini Fantham, 1930 are regarded as junior synonyms of the species. Phylogenetic analysis establishes its affinity with marine fish trypanosomes off Norway.

  19. Improvement of Gynecological Screening of Female Renal Transplant Recipients by Self-Sampling for Human Papillomavirus Detection.

    PubMed

    Hinten, Floor; Hilbrands, Luuk B; Meeuwis, Kim A; van Bergen-Verkuyten, Muriël C; Slangen, Brigitte F; van Rossum, Michelle M; Rahamat-Langendoen, Janette; Massuger, Leon F; de Hullu, Joanne A; Melchers, Willem J

    2017-01-01

    Female renal transplant recipients (RTRs) have increased risk for developing human papillomavirus (HPV)-related (pre)malignancies of the lower genital tract. Annual cervical screening is advised for RTRs, but the participation rate is low. The aim of this study is to investigate whether HPV self-sampling is suitable for gynecological screening of RTRs to increase participation rate. A large cohort of 253 RTRs was investigated for the prevalence of HPV. All participants received a device for a cervicovaginal self-sample. Questionnaires were sent to assess the experience with this device. High-risk (hrHPV) presence was determined with the SPF10-LiPA25 system and GP5+/6+ PCR. HrHPV-positive patients underwent gynecological examination. More than 90% of the patients rated their experience with the self-sample device as good to excellent, and 77% preferred self-sampling over a physician taken sample. Approximately thirty-five of 217 women tested hrHPV positive with SPF10- LiPA25, and 22 tested positive with the GP5+/6+ PCR. Eleven hrHPV-positive patients had clinically relevant gynecological abnormalities, and they all tested positive with GP5+/6+ PCR. Self-sampling is clinically applicable in a gynecological screening and is preferred by female RTRs. Therefore, self-sampling could be implemented with the aim to increase the participation rate of female RTRs in yearly gynecological screening.

  20. [A Method for Selecting Self-Adoptive Chromaticity of the Projected Markers].

    PubMed

    Zhao, Shou-bo; Zhang, Fu-min; Qu, Xing-hua; Zheng, Shi-wei; Chen, Zhe

    2015-04-01

    The authors designed a self-adaptive projection system which is composed of color camera, projector and PC. In detail, digital micro-mirror device (DMD) as a spatial light modulator for the projector was introduced in the optical path to modulate the illuminant spectrum based on red, green and blue light emitting diodes (LED). However, the color visibility of active markers is affected by the screen which has unknown reflective spectrum as well. Here active markers are projected spot array. And chromaticity feature of markers is sometimes submerged in similar spectral screen. In order to enhance the color visibility of active markers relative to screen, a method for selecting self-adaptive chromaticity of the projected markers in 3D scanning metrology is described. Color camera with 3 channels limits the accuracy of device characterization. For achieving interconversion of device-independent color space and device-dependent color space, high-dimensional linear model of reflective spectrum was built. Prior training samples provide additional constraints to yield high-dimensional linear model with more than three degrees of freedom. Meanwhile, spectral power distribution of ambient light was estimated. Subsequently, markers' chromaticity in CIE color spaces was selected via maximization principle of Euclidean distance. The setting values of RGB were easily estimated via inverse transform. Finally, we implemented a typical experiment to show the performance of the proposed approach. An 24 Munsell Color Checker was used as projective screen. Color difference in the chromaticity coordinates between the active marker and the color patch was utilized to evaluate the color visibility of active markers relative to the screen. The result comparison between self-adaptive projection system and traditional diode-laser light projector was listed and discussed to highlight advantage of our proposed method.

  1. Multi-scale temporal patterns in fish presence in a high-velocity tidal channel

    PubMed Central

    Viehman, Haley A.

    2017-01-01

    The natural variation of fish presence in high-velocity tidal channels is not well understood. A better understanding of fish use of these areas would aid in predicting fish interactions with marine hydrokinetic (MHK) devices, the effects of which are uncertain but of high concern. To characterize the patterns in fish presence at a tidal energy site in Cobscook Bay, Maine, we examined two years of hydroacoustic data continuously collected at the proposed depth of an MHK turbine with a bottom-mounted, side-looking echosounder. The maximum number of fish counted per hour ranged from hundreds in the early spring to over 1,000 in the fall. Counts varied greatly with tidal and diel cycles in a seasonally changing relationship, likely linked to the seasonally changing fish community of the bay. In the winter and spring, higher hourly counts were generally confined to ebb tides and low slack tides near sunrise and sunset. In summer and fall of each year, the highest fish counts shifted to night and occurred during ebb, low slack, and flood tides. Fish counts were not linked to current speed, and did not decrease as current speed increased, contrary to observations at other tidal power sites. As fish counts may be proportional to the encounter rate of fish with an MHK turbine at the same depth, highly variable counts indicate that the risk to fish is similarly variable. The links between fish presence and environmental cycles at this site will likely be present at other locations with similar environmental forcing, making these observations useful in predicting potential fish interactions at tidal energy sites worldwide. PMID:28493894

  2. Multi-scale temporal patterns in fish presence in a high-velocity tidal channel.

    PubMed

    Viehman, Haley A; Zydlewski, Gayle Barbin

    2017-01-01

    The natural variation of fish presence in high-velocity tidal channels is not well understood. A better understanding of fish use of these areas would aid in predicting fish interactions with marine hydrokinetic (MHK) devices, the effects of which are uncertain but of high concern. To characterize the patterns in fish presence at a tidal energy site in Cobscook Bay, Maine, we examined two years of hydroacoustic data continuously collected at the proposed depth of an MHK turbine with a bottom-mounted, side-looking echosounder. The maximum number of fish counted per hour ranged from hundreds in the early spring to over 1,000 in the fall. Counts varied greatly with tidal and diel cycles in a seasonally changing relationship, likely linked to the seasonally changing fish community of the bay. In the winter and spring, higher hourly counts were generally confined to ebb tides and low slack tides near sunrise and sunset. In summer and fall of each year, the highest fish counts shifted to night and occurred during ebb, low slack, and flood tides. Fish counts were not linked to current speed, and did not decrease as current speed increased, contrary to observations at other tidal power sites. As fish counts may be proportional to the encounter rate of fish with an MHK turbine at the same depth, highly variable counts indicate that the risk to fish is similarly variable. The links between fish presence and environmental cycles at this site will likely be present at other locations with similar environmental forcing, making these observations useful in predicting potential fish interactions at tidal energy sites worldwide.

  3. Multi-scale temporal patterns in fish presence in a high-velocity tidal channel

    DOE PAGES

    Viehman, Haley A.; Zydlewski, Gayle Barbin; Hewitt, Judi

    2017-05-11

    The natural variation of fish presence in high-velocity tidal channels is not well understood. A better understanding of fish use of these areas would aid in predicting fish interactions with marine hydrokinetic (MHK) devices, the effects of which are uncertain but of high concern. To characterize the patterns in fish presence at a tidal energy site in Cobscook Bay, Maine, we examined two years of hydroacoustic data continuously collected at the proposed depth of an MHK turbine with a bottom-mounted, side-looking echosounder. The maximum number of fish counted per hour ranged from hundreds in the early spring to over 1,000more » in the fall. Counts varied greatly with tidal and diel cycles in a seasonally changing relationship, likely linked to the seasonally changing fish community of the bay. In the winter and spring, higher hourly counts were generally confined to ebb tides and low slack tides near sunrise and sunset. In summer and fall of each year, the highest fish counts shifted to night and occurred during ebb, low slack, and flood tides. Fish counts were not linked to current speed, and did not decrease as current speed increased, contrary to observations at other tidal power sites. As fish counts may be proportional to the encounter rate of fish with an MHK turbine at the same depth, highly variable counts indicate that the risk to fish is similarly variable. The links between fish presence and environmental cycles at this site will likely be present at other locations with similar environmental forcing, making these observations useful in predicting potential fish interactions at tidal energy sites worldwide.« less

  4. Multi-scale temporal patterns in fish presence in a high-velocity tidal channel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Viehman, Haley A.; Zydlewski, Gayle Barbin; Hewitt, Judi

    The natural variation of fish presence in high-velocity tidal channels is not well understood. A better understanding of fish use of these areas would aid in predicting fish interactions with marine hydrokinetic (MHK) devices, the effects of which are uncertain but of high concern. To characterize the patterns in fish presence at a tidal energy site in Cobscook Bay, Maine, we examined two years of hydroacoustic data continuously collected at the proposed depth of an MHK turbine with a bottom-mounted, side-looking echosounder. The maximum number of fish counted per hour ranged from hundreds in the early spring to over 1,000more » in the fall. Counts varied greatly with tidal and diel cycles in a seasonally changing relationship, likely linked to the seasonally changing fish community of the bay. In the winter and spring, higher hourly counts were generally confined to ebb tides and low slack tides near sunrise and sunset. In summer and fall of each year, the highest fish counts shifted to night and occurred during ebb, low slack, and flood tides. Fish counts were not linked to current speed, and did not decrease as current speed increased, contrary to observations at other tidal power sites. As fish counts may be proportional to the encounter rate of fish with an MHK turbine at the same depth, highly variable counts indicate that the risk to fish is similarly variable. The links between fish presence and environmental cycles at this site will likely be present at other locations with similar environmental forcing, making these observations useful in predicting potential fish interactions at tidal energy sites worldwide.« less

  5. Screening the Hanford tanks for trapped gas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whitney, P.

    1995-10-01

    The Hanford Site is home to 177 large, underground nuclear waste storage tanks. Hydrogen gas is generated within the waste in these tanks. This document presents the results of a screening of Hanford`s nuclear waste storage tanks for the presence of gas trapped in the waste. The method used for the screening is to look for an inverse correlation between waste level measurements and ambient atmospheric pressure. If the waste level in a tank decreases with an increase in ambient atmospheric pressure, then the compressibility may be attributed to gas trapped within the waste. In this report, this methodology ismore » not used to estimate the volume of gas trapped in the waste. The waste level measurements used in this study were made primarily to monitor the tanks for leaks and intrusions. Four measurement devices are widely used in these tanks. Three of these measure the level of the waste surface. The remaining device measures from within a well embedded in the waste, thereby monitoring the liquid level even if the liquid level is below a dry waste crust. In the past, a steady rise in waste level has been taken as an indicator of trapped gas. This indicator is not part of the screening calculation described in this report; however, a possible explanation for the rise is given by the mathematical relation between atmospheric pressure and waste level used to support the screening calculation. The screening was applied to data from each measurement device in each tank. If any of these data for a single tank indicated trapped gas, that tank was flagged by this screening process. A total of 58 of the 177 Hanford tanks were flagged as containing trapped gas, including 21 of the 25 tanks currently on the flammable gas watch list.« less

  6. FISH-Flow, a protocol for the concurrent detection of mRNA and protein in single cells using fluorescence in situ hybridization and flow cytometry

    PubMed Central

    Arrigucci, Riccardo; Bushkin, Yuri; Radford, Felix; Lakehal, Karim; Vir, Pooja; Pine, Richard; Martin, December; Sugarman, Jeffrey; Zhao, Yanlin; Yap, George S; Lardizabal, Alfred A; Tyagi, Sanjay; Gennaro, Maria Laura

    2017-01-01

    We describe a flow-cytometry-based protocol for intracellular mRNA measurements in nonadherent mammalian cells using fluorescence in situ hybridization (FISH) probes. The method, which we call FISH-Flow, allows for high-throughput multiparametric measurements of gene expression, a task that was not feasible with earlier, microscopy-based approaches. The FISH-Flow protocol involves cell fixation, permeabilization and hybridization with a set of fluorescently labeled oligonucleotide probes. In this protocol, surface and intracellular protein markers can also be stained with fluorescently labeled antibodies for simultaneous protein and mRNA measurement. Moreover, a semiautomated, single-tube version of the protocol can be performed with a commercially available cell-wash device that reduces cell loss, operator time and interoperator variability. It takes ~30 h to perform this protocol. An example of FISH-Flow measurements of cytokine mRNA induction by ex vivo stimulation of primed T cells with specific antigens is described. PMID:28518171

  7. Signal amplification of FISH for automated detection using image cytometry.

    PubMed

    Truong, K; Boenders, J; Maciorowski, Z; Vielh, P; Dutrillaux, B; Malfoy, B; Bourgeois, C A

    1997-05-01

    The purpose of this study was to improve the detection of FISH signals, in order that spot counting by a fully automated image cytometer be comparable to that obtained visually under the microscope. Two systems of spot scoring, visual and automated counting, were investigated in parallel on stimulated human lymphocytes with FISH using a biotinylated centromeric probe for chromosome 3. Signal characteristics were first analyzed on images recorded with a coupled charge device (CCD) camera. Number of spots per nucleus were scored visually on these recorded images versus automatically with a DISCOVERY image analyzer. Several fluochromes, amplification and pretreatments were tested. Our results for both visual and automated scoring show that the tyramide amplification system (TSA) gives the best amplification of signal if pepsin treatment is applied prior to FISH. Accuracy of the automated scoring, however, remained low (58% of nuclei containing two spots) compared to the visual scoring because of the high intranuclear variation between FISH spots.

  8. Worker satisfaction with personal flotation devices (PFDs) in the fishing industry: evaluations in actual use.

    PubMed

    Lucas, Devin; Lincoln, Jennifer; Somervell, Philip; Teske, Theodore

    2012-07-01

    The purpose of this study was to determine which type of commercially available PFD resulted in the highest satisfaction among workers in the fishing industry. Fishing industry workers on four types of vessels wore and evaluated six different PFDs during their fishing seasons. Linear regression was used to test the differences in mean satisfaction scores, adjusting for clustered observations on vessels. The data were stratified by vessel type to determine the differences in PFD satisfaction within each vessel type. PFD D had the highest mean satisfaction score, but satisfaction with particular PFDs varied depending on the vessel type. Although the common objections by workers to wearing PFDs are that they are bulky and uncomfortable, some of the PFDs that were evaluated in this study received high scores for comfort and satisfaction. Given the availability of PFDs that are comfortable to wear while working, fishing vessel owners and operators should consider implementing policies mandating the use of PFDs on deck. Published by Elsevier Ltd.

  9. Smartphone-based fluorescence spectroscopy device aiding in preliminary skin screening

    NASA Astrophysics Data System (ADS)

    Sahoo, Aparajita; Wahi, Akshat; Das, Anshuman

    2018-02-01

    Preliminary diagnosis of closely resembling skin conditions can be highly subjective for dermatologists. In ambiguous cases, it often leads to performing invasive procedures like biopsies. Different skin conditions, however, have varying concentrations of fluorophores (like collagen, NADH) and chromophores (like melanin, hemoglobin) which can alter their fluorescence spectra. We demonstrate a handheld, portable, smartphone-based spectrometer that leverages these alterations in skin autofluorescence spectra for rapid screening of skin conditions. This methodology involves excitation of affected skin areas with ultraviolet (UV-A) 385 nm light, capturing the generated fluorescence spectra and sending the data wirelessly to a companion mobile application for data storage, analysis and visualization. By collecting the fluorescence spectral signals from healthy and unhealthy skin conditions, we establish that the signals collected using this portable device can be used to develop a classification method to help in differentially diagnosing these conditions. It shows promise as a useful skin screening tool for both dermatologists and primary health care workers. This device can enable quick, non-invasive and a more objective preliminary examination. We envision the device to be especially useful in primary healthcare centers of developing countries where availability of dermatologists is limited.

  10. Ability of certain plant extracts traditionally used to treat ciguatera fish poisoning to inhibit nitric oxide production in RAW 264.7 macrophages.

    PubMed

    Kumar-Roiné, Shilpa; Matsui, Mariko; Reybier, Karine; Darius, Hélène Taiana; Chinain, Mireille; Pauillac, Serge; Laurent, Dominique

    2009-06-25

    Ciguatera fish poisoning (CFP) is an intertropical ichthyosarcotoxism that manifests in complex assortment of symptoms in humans. Ciguatoxins (CTXs), issued from Gambierdicus spp., are causative agents of this intoxication. We have recently demonstrated that a Pacific CTX (P-CTX-1B) strongly modulated iNOS expression, leading to overproduction of nitric oxide (NO) in RAW 264.7 murine macrophage cells. NO produced in large amounts is involved in a wide range of pathophysiological processes. Many traditional remedies are commonly used in the Pacific against CFP. In this context, bioassay-guided screening was carried out to study NO inhibiting capacity of 28 selected plant extracts. We prepared aqueous extracts of plants used in New Caledonia in the treatment of CFP and screened their NO inhibitory activity in lipopolysaccharide (LPS)-activated RAW 264.7 macrophages. Among 28 plants tested, Euphorbia hirta (Euphorbiaceae), Syzygium malaccense (Myrtaceae), Schinus terebenthifolius (Anacardiaceae), Punica granatum (Punicaceae), Cerbera manghas (Apocynaceae), Vitex trifolia (Labiateae) and Ximenia americana (Olacaceae) showed inhibitory activity, validating their use as traditional remedies in CFP, and the potential for use in the treatment of conditions accompanied by NO overproduction. These plants are promising candidates for further screening of their active compounds through activity-guided fractionation.

  11. Population Viability Analysis of Riverine Fishes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bates, P.; Chandler, J.; Jager, H.I.

    Many utilities face conflkts between two goals: cost-efficient hydropower generation and protecting riverine fishes. Research to develop ecological simulation tools that can evaluate alternative mitigation strategies in terms of their benefits to fish populations is vital to informed decision-making. In this paper, we describe our approach to population viability analysis of riverine fishes in general and Snake River white sturgeon in particular. We are finding that the individual-based modeling approach used in previous in-stream flow applications is well suited to addressing questions about the viability of species of concern for several reasons. Chief among these are: (1) the abiIity tomore » represent the effects of individual variation in life history characteristics on predicted population viabili~, (2) the flexibili~ needed to quanti~ the ecological benefits of alternative flow management options by representing spatial and temporal variation in flow and temperaturty and (3) the flexibility needed to quantifi the ecological benefits of non-flow related manipulations (i.e., passage, screening and hatchery supplementation).« less

  12. Distribution and human health risk assessment of PAHs in four fish species from a SW Atlantic estuary.

    PubMed

    Oliva, Ana L; La Colla, Noelia S; Arias, Andrés H; Blasina, Gabriela E; Lopez Cazorla, Andrea; Marcovecchio, Jorge E

    2017-08-01

    The aim of this study is to assess-for the first time-the concentration of the 16 polycyclic aromatic hydrocarbons (PAHs) in the muscle tissues of four fish species (Micropogonias furnieri, Cynoscion guatucupa, Ramnogaster arcuata, and Mustelus schmitti) from Bahía Blanca estuary, Argentina and to evaluate their sources, distribution, and the human health risks implicated. Considering the four species under study, mean total PAH concentrations showed the following decreasing accumulation trend: M. schmitti, R. arcuata, C. guatucupa, and M. furnieri. Low molecular weight PAHs, such as naphthalene and phenanthrene, were generally predominant, displaying properties of PAH mixtures generated from petrogenic pollution. Of the four fish species analyzed, M. furnieri was the only one that did not raise any human consumption warning. In the case of the other species, exceeding values were found above the safety human consumption guidelines. Nevertheless, the screening criteria for carcinogenic PAHs proposed by the USEPA indicated a good quality status for these fish species.

  13. Evidence for leptin expression in fishes.

    PubMed

    Johnson, R M; Johnson, T M; Londraville, R L

    2000-06-01

    Tissues from bony fish were screened with anti-mouse leptin antibodies to detect the presence of the fat-regulating hormone in fishes. Low molecular-weight (16 kDa) immunoreactive bands were detected in blood, brain, heart and liver of green sunfish (Lepomis cyanellus), bluegill sunfish (Lepomis macrochirus), largemouth bass (Micropterus salmoides), white crappie (Pomonix annularis), channel catfish (Ictalurus punctatus), and rainbow trout (Oncorhynchus mykiss). To further verify that we had identified leptin, the response of fish "leptin" was measured in fed and fasted green sunfish. Fed sunfish had approximately threefold higher concentration of leptin in blood than did fasted sunfish (fed vs. fasted; 0.599 +/- 0.03 microg/microl vs. 0.196 +/- 0.04 microg/microl; P > F = 0.0001), which is consistent with mammalian models of leptin function. Brain leptin concentration is also positively correlated with percent body fat in white crappie and bluegill. Based upon electrophoretic mobility, immunoreactivity, response to fasting, and correlation with adiposity, we believe we have the first evidence for leptin expression in an ectotherm.

  14. Work package 4 report: Broodfish testing for bacterial infections

    USGS Publications Warehouse

    Michel, Christian; Elliott, Diane G.; Jansson, Eva; Urdaci, Maria; Midtlyng, Paul J.

    2005-01-01

    This report summarises current scientific information and experience obtained with various methods for testing of salmonid broodfish or spawn for bacterial kidney disease (BKD - Renibacterium salmoninarum infection) in order to prevent vertical transmission of the organism to the offspring. Assessment is also being performed for Flavobacterium psychrophilum infections causing rainbow trout fry syndrome (RTFS) or bacterial coldwater disease (CWD), and for Piscirickettsia salmonis infection causing salmon rickettsial syndrome (SRS) in salmonid fish species. Methods for screening to document the absence of BKD in fish populations are well established. Some of them have also proven successful for testing individual fish from infected populations in order to avoid vertical transmission of the infectious agent. Several diagnostic methods for flavobacteriosis and piscirickettsiosis have also been established but none of them, as yet, has been validated for use in programmes to prevent vertical transmission of disease. Priority subjects for further research in order to improve the management and control of these vertically transmissible fish diseases are suggested.

  15. Characterization of Fish Passage Conditions through a Francis Turbine, Spillway, and Regulating Outlet at Detroit Dam, Oregon, Using Sensor Fish, 2009

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duncan, Joanne P.; Carlson, Thomas J.

    2011-05-06

    Fish passage conditions through two spillways, a Francis turbine, and a regulating outlet (RO) at Detroit Dam on the North Santiam River in Oregon were evaluated by Pacific Northwest National Laboratory for the U.S. Army Corps of Engineers (USACE), Portland District, using Sensor Fish devices. The objective of the study was to describe and compare passage exposure conditions, identifying potential fish injury regions within the routes. The study was performed in July, October, and December 2009 concurrent with HI-Z balloon-tag studies by Normandeau Associates, Inc. Sensor Fish data were analyzed to estimate 1) exposure conditions, particularly exposure to severe strike,more » collision, and shear events by passage route sub-regions; 2) differences in passage conditions between passage routes; and 3) relationships to live-fish injury and mortality data estimates. Comparison of the three passage routes evaluated at Detroit Dam indicates that the RO passage route through the 5-ft gate opening was relatively the safest route for fish passage under the operating conditions tested; turbine passage was the most deleterious. These observations were supported also by the survival and malady estimates obtained from live-fish testing. Injury rates were highest for turbine and spillway passage. However, none of the passage routes tested is safe for juvenile salmonid passage.« less

  16. Reading and Studying on the Screen: An Overview of Literature towards Good Learning Design Practice

    ERIC Educational Resources Information Center

    Nichols, Mark

    2016-01-01

    As distance education moves increasingly towards online provision, and because of the benefits provided by online approaches, students will be expected to engage with more resources available on screen. Contemporary forms of reading from the screen include reading from tablet devices, LCD monitors, and smartphones. However, print remains the…

  17. Screening probiotic candidates for a mixture of probiotics to enhance the growth performance, immunity, and disease resistance of Asian seabass, Lates calcarifer (Bloch), against Aeromonas hydrophila.

    PubMed

    Lin, Hsueh-Li; Shiu, Ya-Li; Chiu, Chiu-Shia; Huang, Shih-Ling; Liu, Chun-Hung

    2017-01-01

    Six bacteria, including, Lactobacillus casei M15, Lac. plantarum D8, Lac. pentosus BD6, Lac. fermentum LW2, Enterococcus faecium 10-10, and Bacillus subtilis E20, and one yeast, Saccharomyces cerevisiae P13 were selected as probiotics for Asian seabass, Lates calcarifer, by tracking the growth performance and disease resistance of fish against Aeromonas hydrophila in the first trial. The probiotic efficiency screening results showed that B. subtilis E20 and Lac. pentosus BD6, and S. cerevisiae P13 and Lac. fermentum LW2 respectively improved either the growth performance or disease resistance. Therefore, these four probiotics were then selected to prepare a probiotics mixture, and this was incorporated in equal proportions into diets for Asian seabass at levels of 0 (control), and 10 6 (MD6), 10 7 (MD7), 10 8 (MD8), and 10 9 (MD9) colony-forming units (cfu) (kg diet) -1 . A synergistic effect of the combined probiotics was investigated in this study, and the probiotics mixture was able to improve both the growth performance and health status of fish. After 56 days of feeding, fish fed the MD9 diet had a higher final weight and percentage of weight gain. In addition, protein contents in the dorsal muscle of fish fed the MD8 and MD9 diets were significantly higher compared to the control. For the pathogen challenge test, fish fed the MD7, MD8, and MD9 diets had significantly lower cumulative mortalities after A. hydrophila infection compared to those of fish fed the control and MD6 diets, which might have been due to increased respiratory bursts, decreased superoxide dismutase activity in leucocytes, and increased phagocytic activity. Therefore, we considered that the probiotics mixture could adequately provide probiotic efficiency for Asian seabass, and the diet containing 10 9  cfu (kg diet) -1 probiotic mixture is recommended to improve the growth and health status of Asian seabass. Copyright © 2016. Published by Elsevier Ltd.

  18. Evidence of Increased Antibiotic Resistance in Phylogenetically-Diverse Aeromonas Isolates from Semi-Intensive Fish Ponds Treated with Antibiotics.

    PubMed

    Patil, Hemant J; Benet-Perelberg, Ayana; Naor, Alon; Smirnov, Margarita; Ofek, Tamir; Nasser, Ahmed; Minz, Dror; Cytryn, Eddie

    2016-01-01

    The genus Aeromonas is ubiquitous in aquatic environments encompassing a broad range of fish and human pathogens. Aeromonas strains are known for their enhanced capacity to acquire and exchange antibiotic resistance genes and therefore, are frequently targeted as indicator bacteria for monitoring antimicrobial resistance in aquatic environments. This study evaluated temporal trends in Aeromonas diversity and antibiotic resistance in two adjacent semi-intensive aquaculture facilities to ascertain the effects of antibiotic treatment on antimicrobial resistance. In the first facility, sulfadiazine-trimethoprim was added prophylactically to fingerling stocks and water column-associated Aeromonas were monitored periodically over an 11-month fish fattening cycle to assess temporal dynamics in taxonomy and antibiotic resistance. In the second facility, Aeromonas were isolated from fish skin ulcers sampled over a 3-year period and from pond water samples to assess associations between pathogenic strains to those in the water column. A total of 1200 Aeromonas isolates were initially screened for sulfadiazine resistance and further screened against five additional antimicrobials. In both facilities, strong correlations were observed between sulfadiazine resistance and trimethoprim and tetracycline resistances, whereas correlations between sulfadiazine resistance and ceftriaxone, gentamicin, and chloramphenicol resistances were low. Multidrug resistant strains as well as sul1, tetA , and intI1 gene-harboring strains were significantly higher in profiles sampled during the fish cycle than those isolated prior to stocking and these genes were extremely abundant in the pathogenic strains. Five phylogenetically distinct Aeromonas clusters were identified using partial rpoD gene sequence analysis. Interestingly, prior to fingerling stocking the diversity of water column strains was high, and representatives from all five clusters were identified, including an A. salmonicida cluster that harbored all characterized fish skin ulcer samples. Subsequent to stocking, diversity was much lower and most water column isolates in both facilities segregated into an A. veronii -associated cluster. This study demonstrated a strong correlation between aquaculture, Aeromonas diversity and antibiotic resistance. It provides strong evidence for linkage between prophylactic and systemic use of antibiotics in aquaculture and the propagation of antibiotic resistance.

  19. Evidence of Increased Antibiotic Resistance in Phylogenetically-Diverse Aeromonas Isolates from Semi-Intensive Fish Ponds Treated with Antibiotics

    PubMed Central

    Patil, Hemant J.; Benet-Perelberg, Ayana; Naor, Alon; Smirnov, Margarita; Ofek, Tamir; Nasser, Ahmed; Minz, Dror; Cytryn, Eddie

    2016-01-01

    The genus Aeromonas is ubiquitous in aquatic environments encompassing a broad range of fish and human pathogens. Aeromonas strains are known for their enhanced capacity to acquire and exchange antibiotic resistance genes and therefore, are frequently targeted as indicator bacteria for monitoring antimicrobial resistance in aquatic environments. This study evaluated temporal trends in Aeromonas diversity and antibiotic resistance in two adjacent semi-intensive aquaculture facilities to ascertain the effects of antibiotic treatment on antimicrobial resistance. In the first facility, sulfadiazine-trimethoprim was added prophylactically to fingerling stocks and water column-associated Aeromonas were monitored periodically over an 11-month fish fattening cycle to assess temporal dynamics in taxonomy and antibiotic resistance. In the second facility, Aeromonas were isolated from fish skin ulcers sampled over a 3-year period and from pond water samples to assess associations between pathogenic strains to those in the water column. A total of 1200 Aeromonas isolates were initially screened for sulfadiazine resistance and further screened against five additional antimicrobials. In both facilities, strong correlations were observed between sulfadiazine resistance and trimethoprim and tetracycline resistances, whereas correlations between sulfadiazine resistance and ceftriaxone, gentamicin, and chloramphenicol resistances were low. Multidrug resistant strains as well as sul1, tetA, and intI1 gene-harboring strains were significantly higher in profiles sampled during the fish cycle than those isolated prior to stocking and these genes were extremely abundant in the pathogenic strains. Five phylogenetically distinct Aeromonas clusters were identified using partial rpoD gene sequence analysis. Interestingly, prior to fingerling stocking the diversity of water column strains was high, and representatives from all five clusters were identified, including an A. salmonicida cluster that harbored all characterized fish skin ulcer samples. Subsequent to stocking, diversity was much lower and most water column isolates in both facilities segregated into an A. veronii-associated cluster. This study demonstrated a strong correlation between aquaculture, Aeromonas diversity and antibiotic resistance. It provides strong evidence for linkage between prophylactic and systemic use of antibiotics in aquaculture and the propagation of antibiotic resistance. PMID:27965628

  20. New approach for fish breeding by chemical mutagenesis: establishment of TILLING method in fugu (Takifugu rubripes) with ENU mutagenesis.

    PubMed

    Kuroyanagi, Miwa; Katayama, Takashi; Imai, Tadashi; Yamamoto, Yoshihisa; Chisada, Shin-ichi; Yoshiura, Yasutoshi; Ushijima, Tomokazu; Matsushita, Tomonao; Fujita, Masashi; Nozawa, Aoi; Suzuki, Yuzuru; Kikuchi, Kiyoshi; Okamoto, Hiroyuki

    2013-11-13

    In fish breeding, it is essential to discover and generate fish exhibiting an effective phenotype for the aquaculture industry, but screening for natural mutants by only depending on natural spontaneous mutations is limited. Presently, reverse genetics has become an important tool to generate mutants, which exhibit the phenotype caused by inactivation of a gene. TILLING (Targeting Induced Local Lesions IN Genomes) is a reverse genetics strategy that combines random chemical mutagenesis with high-throughput discovery technologies for screening the induced mutations in target genes. Although the chemical mutagenesis has been used widely in a variety of model species and also genetic breeding of microorganisms and crops, the application of the mutagenesis in fish breeding has been only rarely reported. In this study, we developed the TILLING method in fugu with ENU mutagenesis and high-resolution melting (HRM) analysis to detect base pair changes in target sequences. Fugu males were treated 3 times at weekly intervals with various ENU concentrations, and then the collected sperm after the treatment was used to fertilize normal female for generating the mutagenized population (F1). The fertilization and the hatching ratios were similar to those of the control and did not reveal a dose dependency of ENU. Genomic DNA from the harvested F1 offspring was used for the HRM analysis. To obtain a fish exhibiting a useful phenotype (e.g. high meat production and rapid growth), fugu myostatin (Mstn) gene was examined as a target gene, because it has been clarified that the mstn deficient medaka exhibited double-muscle phenotype in common with MSTN knockout mice and bovine MSTN mutant. As a result, ten types of ENU-induced mutations were identified including a nonsense mutation in the investigated region with HRM analysis. In addition, the average mutation frequency in fugu Mstn gene was 1 mutant per 297 kb, which is similar to values calculated for zebrafish and medaka TILLING libraries. These results demonstrate that the TILLING method in fugu was established. We anticipate that this TILLING approach can be used to generate a wide range of mutant alleles, and be applicable to many farmed fish that can be chemically mutagenized.

Top