Wass, Sam V; Smith, Tim J
2014-07-01
Little research hitherto has examined how individual differences in attention, as assessed using standard experimental paradigms, relate to individual differences in how attention is spontaneously allocated in more naturalistic contexts. Here, we analyzed the time intervals between refoveating eye movements (fixation durations) while typically developing 11-month-old infants viewed a 90-min battery ranging from complex dynamic to noncomplex static materials. The same infants also completed experimental assessments of cognitive control, psychomotor reaction times (RT), processing speed (indexed via peak look during habituation), and arousal (indexed via tonic pupil size). High test-retest reliability was found for fixation duration, across testing sessions and across types of viewing material. Increased cognitive control and increased arousal were associated with reduced variability in fixation duration. For fixations to dynamic stimuli, in which a large proportion of saccades may be exogenously cued, we found that psychomotor RT measures were most predictive of mean fixation duration; for fixations to static stimuli, in contrast, in which there is less exogenous attentional capture, we found that psychomotor RT did not predict performance, but that measures of cognitive control and arousal did. The implications of these findings for understanding the development of attentional control in naturalistic settings are discussed.
Wass, Sam V; Smith, Tim J
2014-01-01
Little research hitherto has examined how individual differences in attention, as assessed using standard experimental paradigms, relate to individual differences in how attention is spontaneously allocated in more naturalistic contexts. Here, we analyzed the time intervals between refoveating eye movements (fixation durations) while typically developing 11-month-old infants viewed a 90-min battery ranging from complex dynamic to noncomplex static materials. The same infants also completed experimental assessments of cognitive control, psychomotor reaction times (RT), processing speed (indexed via peak look during habituation), and arousal (indexed via tonic pupil size). High test–retest reliability was found for fixation duration, across testing sessions and across types of viewing material. Increased cognitive control and increased arousal were associated with reduced variability in fixation duration. For fixations to dynamic stimuli, in which a large proportion of saccades may be exogenously cued, we found that psychomotor RT measures were most predictive of mean fixation duration; for fixations to static stimuli, in contrast, in which there is less exogenous attentional capture, we found that psychomotor RT did not predict performance, but that measures of cognitive control and arousal did. The implications of these findings for understanding the development of attentional control in naturalistic settings are discussed. PMID:25635173
The Importance of "What": Infants Use Featural Information to Index Events
ERIC Educational Resources Information Center
Kirkham, Natasha Z.; Richardson, Daniel C.; Wu, Rachel; Johnson, Scott P.
2012-01-01
Dynamic spatial indexing is the ability to encode, remember, and track the location of complex events. For example, in a previous study, 6-month-old infants were familiarized to a toy making a particular sound in a particular location, and later they fixated that empty location when they heard the sound presented alone ("Journal of Experimental…
[Results of femoral lengthening over an intramedullary nail and external fixator].
Jasiewicz, Barbara; Kacki, Wojciech; Tesiorowski, Maciej; Potaczek, Tomasz
2008-01-01
Current techniques of operative limb lengthening usually are based on distraction osteogenesis. One of the techniques is limb lengthening over an intramedullary nail. The goal of this study is to evaluate the results of femoral lengthening over an intramedullary nail. Between 1999 and 200619 femoral "over nail" lengthenings were performed. There were 7 males and 12 females. Mean patients' age at surgery was 15.8 years, and mean initial femoral shortening was 5.1 cm. Operative technique consisted of one-stage implantation of intramedullary nail and external fixator. Ilizarov apparatus was used in 9 patients, monolateral fixator in 10 cases--ORTHOFIX in 9 patients, Wagner fixator--in 1 patient. Intramedullary nail was locked proximally with screws or Schanz pins from external fixator. After distraction phase, external fixator was removed and distal locking screws were applied. Evaluation criteria: obtained lengthening, time of external fixator, treatment time, healing index, external fixation index, range of motion in hip and knee joints and complications according to Paley. The mean lengthening was 4.6 cm, and mean distraction time was 66.6 days. Mean time of external fixation was 115.5 days, and external fixation index was 26.2 days for centimeter. Healing index was 36.9 days for centimeter. In cases with monolateral fixator, healing index did not differ with the whole group. During treatment 18 complications occurred, for a rate of 0.9 complication per segment. Lengthening over an intramedullary nail reduces the time of external fixator. Over nail femoral lengthening can prevent axis deviation following regenerate bending. Complication rate is similar to lengthenings with the classic Ilizarov technique. There are no differences in the treatment time in relation to the type of external fixator.
Morales, Marco U; Saker, Saker; Wilde, Craig; Pellizzari, Carlo; Pallikaris, Aristophanes; Notaroberto, Neil; Rubinstein, Martin; Rui, Chiara; Limoli, Paolo; Smolek, Michael K; Amoaku, Winfried M
2016-11-01
The purpose of this study was to establish a normal reference database for fixation stability measured with the bivariate contour ellipse area (BCEA) in the Macular Integrity Assessment (MAIA) microperimeter. Subjects were 358 healthy volunteers who had the MAIA examination. Fixation stability was assessed using two BCEA fixation indices (63% and 95% proportional values) and the percentage of fixation points within 1° and 2° from the fovea (P1 and P2). Statistical analysis was performed with linear regression and Pearson's product moment correlation coefficient. Average areas of 0.80 deg 2 (min = 0.03, max = 3.90, SD = 0.68) for the index BCEA@63% and 2.40 deg 2 (min = 0.20, max = 11.70, SD = 2.04) for the index BCEA@95% were found. The average values of P1 and P2 were 95% (min = 76, max = 100, SD = 5.31) and 99% (min = 91, max = 100, SD = 1.42), respectively. The Pearson's product moment test showed an almost perfect correlation index, r = 0.999, between BCEA@63% and BCEA@95%. Index P1 showed a very strong correlation with BCEA@63%, r = -0.924, as well as with BCEA@95%, r = -0.925. Index P2 demonstrated a slightly lower correlation with both BCEA@63% and BCEA@95%, r = -0.874 and -0.875, respectively. The single parameter of the BCEA@95% may be taken as accurately reporting fixation stability and serves as a reference database of normal subjects with a cutoff area of 2.40 ± 2.04 deg 2 in MAIA microperimeter. Fixation stability can be measured with different indices. This study originates reference fixation values for the MAIA using a single fixation index.
Optical parameters of the tunable Bragg reflectors in squid.
Ghoshal, Amitabh; Demartini, Daniel G; Eck, Elizabeth; Morse, Daniel E
2013-08-06
Cephalopods (e.g. octopus, squid and cuttlefish) dynamically tune the colour and brightness of their skin for camouflage and communication using specialized skin cells called iridocytes. We use high-resolution microspectrophotometry to investigate individual tunable Bragg structures (consisting of alternating reflectin protein-containing, high-refractive index lamellae and low-refractive index inter-lamellar spaces) in live and chemically fixed iridocytes of the California market squid, Doryteuthis opalescens. This subcellular, single-stack microspectrophotometry allows for spectral normalization, permitting use of a transfer-matrix model of Bragg reflectance to calculate all the parameters of the Bragg stack-the refractive indices, dimensions and numbers of the lamellae and inter-lamellar spaces. Results of the fitting analyses show that eight or nine pairs of low- and high-index layers typically contribute to the observed reflectivity in live cells, whereas six or seven pairs of low- and high-index layers typically contribute to the reflectivity in chemically fixed cells. The reflectin-containing, high-index lamellae of live cells have a refractive index proportional to the peak reflectivity, with an average of 1.405 ± 0.012 and a maximum around 1.44, while the reflectin-containing lamellae in fixed tissue have a refractive index of 1.413 ± 0.015 suggesting a slight increase of refractive index in the process of fixation. As expected, incremental changes in refractive index contribute to the greatest incremental changes in reflectivity for those Bragg stacks with the most layers. The excursions in dimensions required to tune the measured reflected wavelength from 675 (red) to 425 nm (blue) are a decrease from ca 150 to 80 nm for the high-index lamellae and from ca 120 to 50 nm for the low-index inter-lamellar spaces. Fixation-induced dimensional changes also are quantified, leading us to suggest that further microspectrophotometric analyses of this iridocyte system can be used as a model system to quantify the effects of various methods of tissue fixation. The microspectrophotometry technique described can be expected to provide deeper insights into the molecular and physical mechanisms governing other biophotonically active cells and structures.
Optical parameters of the tunable Bragg reflectors in squid
Ghoshal, Amitabh; DeMartini, Daniel G.; Eck, Elizabeth; Morse, Daniel E.
2013-01-01
Cephalopods (e.g. octopus, squid and cuttlefish) dynamically tune the colour and brightness of their skin for camouflage and communication using specialized skin cells called iridocytes. We use high-resolution microspectrophotometry to investigate individual tunable Bragg structures (consisting of alternating reflectin protein-containing, high-refractive index lamellae and low-refractive index inter-lamellar spaces) in live and chemically fixed iridocytes of the California market squid, Doryteuthis opalescens. This subcellular, single-stack microspectrophotometry allows for spectral normalization, permitting use of a transfer-matrix model of Bragg reflectance to calculate all the parameters of the Bragg stack—the refractive indices, dimensions and numbers of the lamellae and inter-lamellar spaces. Results of the fitting analyses show that eight or nine pairs of low- and high-index layers typically contribute to the observed reflectivity in live cells, whereas six or seven pairs of low- and high-index layers typically contribute to the reflectivity in chemically fixed cells. The reflectin-containing, high-index lamellae of live cells have a refractive index proportional to the peak reflectivity, with an average of 1.405 ± 0.012 and a maximum around 1.44, while the reflectin-containing lamellae in fixed tissue have a refractive index of 1.413 ± 0.015 suggesting a slight increase of refractive index in the process of fixation. As expected, incremental changes in refractive index contribute to the greatest incremental changes in reflectivity for those Bragg stacks with the most layers. The excursions in dimensions required to tune the measured reflected wavelength from 675 (red) to 425 nm (blue) are a decrease from ca 150 to 80 nm for the high-index lamellae and from ca 120 to 50 nm for the low-index inter-lamellar spaces. Fixation-induced dimensional changes also are quantified, leading us to suggest that further microspectrophotometric analyses of this iridocyte system can be used as a model system to quantify the effects of various methods of tissue fixation. The microspectrophotometry technique described can be expected to provide deeper insights into the molecular and physical mechanisms governing other biophotonically active cells and structures. PMID:23740489
A model based on temporal dynamics of fixations for distinguishing expert radiologists' scanpaths
NASA Astrophysics Data System (ADS)
Gandomkar, Ziba; Tay, Kevin; Brennan, Patrick C.; Mello-Thoms, Claudia
2017-03-01
This study investigated a model which distinguishes expert radiologists from less experienced radiologists based on features describing spatio-temporal dynamics of their eye movement during interpretation of digital mammograms. Eye movements of four expert and four less experienced radiologists were recorded during interpretation of 120 two-view digital mammograms of which 59 had biopsy proven cancers. For each scanpath, a two-dimensional recurrence plot, which represents the radiologist's refixation pattern, was generated. From each plot, six features indicating the spatio-temporal dynamics of fixations were extracted. The first feature measured the percentage of recurrent fixations; the second indicated the percentage of recurrent fixations which was fixated later in several consecutive fixations; the third measured the percentage of recurrent fixations that form a repeated sequence of fixations and the fourth assessed whether the recurrent fixations were occurring sequentially close together. The number of switches between the two mammographic views was also measured, as was the average number of consecutive fixations in each view before switching. These six features along with total time on case and average fixation duration were fed into a support vector machine whose performance was evaluated using 10-fold cross validation. The model achieved a sensitivity of 86.3% and a specificity of 85.2% for distinguishing experts' scanpaths. The obtained result suggests that spatio-temporal dynamics of eye movements can characterize expertise level and has potential applications for monitoring the development of expertise among radiologists as a result of different training regimes and continuing education schemes.
Nonexplicit change detection in complex dynamic settings: what eye movements reveal.
Vachon, François; Vallières, Benoît R; Jones, Dylan M; Tremblay, Sébastien
2012-12-01
We employed a computer-controlled command-and-control (C2) simulation and recorded eye movements to examine the extent and nature of the inability to detect critical changes in dynamic displays when change detection is implicit (i.e., requires no explicit report) to the operator's task. Change blindness-the failure to notice significant changes to a visual scene-may have dire consequences on performance in C2 and surveillance operations. Participants performed a radar-based risk-assessment task involving multiple subtasks. Although participants were not required to explicitly report critical changes to the operational display, change detection was critical in informing decision making. Participants' eye movements were used as an index of visual attention across the display. Nonfixated (i.e., unattended) changes were more likely to be missed than were fixated (i.e., attended) changes, supporting the idea that focused attention is necessary for conscious change detection. The finding of significant pupil dilation for changes undetected but fixated suggests that attended changes can nonetheless be missed because of a failure of attentional processes. Change blindness in complex dynamic displays takes the form of failures in establishing task-appropriate patterns of attentional allocation. These findings have implications in the design of change-detection support tools for dynamic displays and work procedure in C2 and surveillance.
Colcuc, Christian; Blank, Marc; Stein, Thomas; Raimann, Florian; Weber-Spickschen, Sanjay; Fischer, Sebastian; Hoffmann, Reinhard
2017-12-09
Suture button devices for tibiofibular syndesmosis injuries provide semirigid dynamic stabilization, but complications including knot irritation have been reported. No randomized trials of the new knotless suture button devices have been performed. We hypothesized that knotless suture button devices eliminate knot irritation and facilitate quicker return to sports. This study was performed to compare the clinical outcomes, complication rates, and time to return to sports between a new knotless suture button device and syndesmotic screw fixation. This study included 54 patients treated for ankle syndesmotic injury from 2012 to 2014 with a knotless suture button device or syndesmotic screw fixation. Clinical outcomes were measured using the American Orthopaedics Foot and Ankle Society score, Foot and Ankle Disability Index, Olerud and Molander score, and visual analog scale for pain and function. Secondary outcome measures were the complication rate and time required to return to sports. Patients underwent clinical and radiological evaluations preoperatively and three times during the 1-year postoperative follow-up. 54 of 62 eligible patients were analyzed, median age 37 (18-60) and underwent the 1-year follow-up. The screw fixation and knotless suture button groups comprised 26 and 28 patients, respectively. The complication rate was significantly lower (p = 0.03) and time to return to sports was significantly shorter in the knotless suture button than screw fixation group (average, 14 versus 19 weeks, respectively; p = 0.006). No significant differences were identified in clinical outcomes or visual analog scale scores for pain and function between the groups. Age, injury mechanism, and body mass index did not significantly affect the time required to return to sports activities. The type of fixation was the only independent variable that reached statistical significance (p = 0.006). Syndesmotic screw fixation and the new knotless suture button device both resulted in good clinical results. Lower complication rate and the earlier time to return to sports make the new knotless suture button device recommendable especially for highly active patients. Randomized controlled trial, Level I.
Bajwa, Ali S.; Rammappa, Manju; Lee, Ling; Nanda, Rajesh
2015-01-01
Introduction: Distal radius fracture (DRF) is a common injury and various treatment modalities including open reduction and internal fixation (ORIF) with volar locking plate are available. More recently, a non-invasive external fixator has been used. Aims: To prospectively compare the use of a non-invasive external fixator with early dynamisation for DRF against ORIF with volar locking plate control group. Methods: Consecutive patients with closed DRF were included in a prospective case-controlled study. Patients were assigned to non-invasive external fixator or ORIF. Minimum follow-up was two years. Follow-up was at weeks 2, 4, 6, 8, 12, 26 and at one and two-year post-operatively. The outcome measures included demographic details, injury mechanism, AO fracture type, risk factors, body mass index (BMI), ulnar styloid fracture and dorsal comminution, radiographs, grip strength and DASH score. Results: Consecutive 50 patients were treated either with non-invasive external fixator (25/50) or with ORIF (25/50) and the mean age of the two groups was 53 years (SD 17.1) and 49 years (SD 19.5), respectively. Demographics were matched in two groups. In the non-invasive external fixator group, there were 10 AO Type-A, 5 Type-B and 10 Type-C fractures. The ORIF group included 8 Type-A, 6 Type-B and 11 Type-C fractures. The mean DASH score at three-months and one-year post-injury in non-invasive fixator group was 12.2 (SD 3.1) and 3.5 (SD 0.7), respectively, significantly greater than those of ORIF group 14.5 (SD 5.6) and 11.2 (SD 4.4), respectively (p < 0.05). Conclusion: DRF treated with non-invasive external fixator can give functional results superior to ORIF at three-months and the trend is maintained at one and two-year post-operatively. PMID:27163089
Fixation Times in Deme Structured, Finite Populations with Rare Migration
NASA Astrophysics Data System (ADS)
Hauert, Christoph; Chen, Yu-Ting; Imhof, Lorens A.
2014-08-01
Population structure affects both the outcome and the speed of evolutionary dynamics. Here we consider a finite population that is divided into subpopulations called demes. The dynamics within the demes are stochastic and frequency-dependent. Individuals can adopt one of two strategic types, or . The fitness of each individual is determined by interactions with other individuals in the same deme. With small probability, proportional to fitness, individuals migrate to other demes. The outcome of these dynamics has been studied earlier by analyzing the fixation probability of a single mutant in an otherwise homogeneous population. These results give only a partial picture of the dynamics, because the time when fixation occurs can be exceedingly large. In this paper, we study the impact of deme structures on the speed of evolution. We derive analytical approximations of fixation times in the limit of rare migration and rare mutation. In this limit, the conditional fixation time of a single mutant in a population is the same as that of a single in an population. For the prisoner's dilemma game, simulation results fit very well with our analytical predictions and demonstrate that fixation takes place in a moderate amount of time as compared to the expected waiting time until a mutant successfully invades and fixates. The simulations also confirm that the conditional fixation time of a single cooperator is indeed the same as that of a single defector.
When the mean is not enough: Calculating fixation time distributions in birth-death processes.
Ashcroft, Peter; Traulsen, Arne; Galla, Tobias
2015-10-01
Studies of fixation dynamics in Markov processes predominantly focus on the mean time to absorption. This may be inadequate if the distribution is broad and skewed. We compute the distribution of fixation times in one-step birth-death processes with two absorbing states. These are expressed in terms of the spectrum of the process, and we provide different representations as forward-only processes in eigenspace. These allow efficient sampling of fixation time distributions. As an application we study evolutionary game dynamics, where invading mutants can reach fixation or go extinct. We also highlight the median fixation time as a possible analog of mixing times in systems with small mutation rates and no absorbing states, whereas the mean fixation time has no such interpretation.
Korovessis, Panagiotis; Papazisis, Zisis; Lambiris, Elias
2002-01-01
This is a prospective comparative randomised study to compare the immediately postoperative effects of a rigid versus dynamic instrumentation for degenerative spine disease and stenosis on the standing sagittal lumbar spine alignment and to investigate if a dynamic spine system can replace the commonly used rigid systems in order to avoid the above mentioned disadvantages of rigid fixation. 15 randomly selected patients received the rigid instrumentation SCS and an equal number of randomly selected patients the dynamic TWINFLEX device for spinal stenosis associated degenerative lumbar disease. The age of the patients, who received rigid and dynamic instrumentation was 65 +/- 9 years and 62 +/- 10 years respectively. All patients had standing spine radiographs preoperatively and three months postoperatively. The parameters that were measured and compared pre- to postoperatively were: lumbar lordosis (L1-S1), total lumbar lordosis (T12-S1), sacral tilt, distal lordosis (L4-S1), intervertebral angulation, vertebral inclination and disc index. The instrumented levels in the spines that received rigid and dynamic instrumentation were 3.5 +/- 0.53 and 3 +/- 0.7 respectively. The instrumented levels from L3 to L5 were 23, the lumbosacral junction was instrumented in 3 patients of group A and in 4 patients of group B. Lumbar lordosis did not significantly change postoperatively, while total lordosis was significantly (P=0.04) increased in the patients who received the rigid instrumentation, while it was significantly (P=0.012) decreased in the group B. Intervertebral angulation of the non-instrumented level L1-L2 was increased in the group A (P=0.01), while the dynamic instrumentation increased (P=0.02) the intervertebral inclination of the adjacent level L2-L3, immediately above the uppermost instrumented level. Distal lordosis and sacral tilt did not change in any patient in both groups. Both instrumentations did not change the lateral vertebral inclination of L1 to L5 vertebrae. Rigid instrumentation increased the lordotic inclination of L5 (P=0.03) and of S1 (P=0.03). Rigid instrumentation increased (P=0.04) the intervertebral angulation at the uppermost instrumented level L3-L4 The most significant change in vertebral angulation was achieved at the instrumented level L4-L5 by the dynamic (P=0.007) and rigid (0.05). The disc index at the level L2-L3 was increased by both instrumentation [dynamic P=0.007 and rigid (P=0.02)]. The index L3-L4 was increased following dynamic fixation (P=0.0007). The disc index L4-L5 was postoperatively increased by both types of instrumentation (rigid P=0.006, dynamic P=0.02). The disc index L5-S1 did not significantly change postoperatively by either system. Both rigid and dynamic instrumentations restored lumbar lordosis, sacral tilt, distal lordosis and increased the foraminal diameter at the level L4-L5 resulting in an indirect decompression of the nerve roots at this level . Both rigid and dynamic instrumentations applied in the lumbosacral spine to treat degenerative disease secured L3 to S1 sagittal spine profile close to preoperative levels, that should theoretically guarantee a pain-free postoperative course. This study supports the belief that the dynamic system can be used with the same indications with the rigid in degenerative lumbar spine because it can offer equally good short-term results regarding sagittal spine alignment while simultaneously it has the previously mentioned advantages (avoidance stress shielding etc).
Optimal Eye-Gaze Fixation Position for Face-Related Neural Responses
Zerouali, Younes; Lina, Jean-Marc; Jemel, Boutheina
2013-01-01
It is generally agreed that some features of a face, namely the eyes, are more salient than others as indexed by behavioral diagnosticity, gaze-fixation patterns and evoked-neural responses. However, because previous studies used unnatural stimuli, there is no evidence so far that the early encoding of a whole face in the human brain is based on the eyes or other facial features. To address this issue, scalp electroencephalogram (EEG) and eye gaze-fixations were recorded simultaneously in a gaze-contingent paradigm while observers viewed faces. We found that the N170 indexing the earliest face-sensitive response in the human brain was the largest when the fixation position is located around the nasion. Interestingly, for inverted faces, this optimal fixation position was more variable, but mainly clustered in the upper part of the visual field (around the mouth). These observations extend the findings of recent behavioral studies, suggesting that the early encoding of a face, as indexed by the N170, is not driven by the eyes per se, but rather arises from a general perceptual setting (upper-visual field advantage) coupled with the alignment of a face stimulus to a stored face template. PMID:23762224
Optimal eye-gaze fixation position for face-related neural responses.
Zerouali, Younes; Lina, Jean-Marc; Jemel, Boutheina
2013-01-01
It is generally agreed that some features of a face, namely the eyes, are more salient than others as indexed by behavioral diagnosticity, gaze-fixation patterns and evoked-neural responses. However, because previous studies used unnatural stimuli, there is no evidence so far that the early encoding of a whole face in the human brain is based on the eyes or other facial features. To address this issue, scalp electroencephalogram (EEG) and eye gaze-fixations were recorded simultaneously in a gaze-contingent paradigm while observers viewed faces. We found that the N170 indexing the earliest face-sensitive response in the human brain was the largest when the fixation position is located around the nasion. Interestingly, for inverted faces, this optimal fixation position was more variable, but mainly clustered in the upper part of the visual field (around the mouth). These observations extend the findings of recent behavioral studies, suggesting that the early encoding of a face, as indexed by the N170, is not driven by the eyes per se, but rather arises from a general perceptual setting (upper-visual field advantage) coupled with the alignment of a face stimulus to a stored face template.
Cai, Zhencun; Li, Lianyong; Zhang, Lijun; Ji, Shijun; Zhao, Qun
2017-02-01
Objective To evaluate the effect of dynamic long leg casting in paediatric patients with developmental dysplasia of hip (DDH) diagnosed at 12-18 months. Methods The adductor tenotomy, closed reduction, and dynamic long leg casting method was adopted to treat paediatric patients with DDH. The hips were divided into four groups according to the Tonnis radiographic dislocation classification. Groups were also classified according to the baseline acetabular index (AI): 30°-35°, 36°-40°, and > 40°. The outcomes of the reductions were evaluated according to McKay's hip function criteria and Severin's radiological criteria. Results A total of 246 patients (339 hips) had complete follow-up data. After 3 months of orthosis fixation, the results were satisfactory in 264 hips (77.88%). Hip function was rated as 'excellent' or 'good' in 43 of 51 (84.31%) Tonnis type 1 hips, 125 of 155 (80.65%) type 2 hips, 70 of 90 (77.78%) type 3 hips, and 34 of 43 (79.07%) type 4 hips. The higher the baseline AI, the lower the rates of 'excellent' and 'good' hip function. Favourable radiological results (Severin types I and II) were found in 266 of 339 (78.47) hips. Conclusions Dynamic long leg casting is an effective method for treating patients with DDH aged 12-18 months at diagnosis.
Mean-field approximations of fixation time distributions of evolutionary game dynamics on graphs
NASA Astrophysics Data System (ADS)
Ying, Li-Min; Zhou, Jie; Tang, Ming; Guan, Shu-Guang; Zou, Yong
2018-02-01
The mean fixation time is often not accurate for describing the timescales of fixation probabilities of evolutionary games taking place on complex networks. We simulate the game dynamics on top of complex network topologies and approximate the fixation time distributions using a mean-field approach. We assume that there are two absorbing states. Numerically, we show that the mean fixation time is sufficient in characterizing the evolutionary timescales when network structures are close to the well-mixing condition. In contrast, the mean fixation time shows large inaccuracies when networks become sparse. The approximation accuracy is determined by the network structure, and hence by the suitability of the mean-field approach. The numerical results show good agreement with the theoretical predictions.
NASA Astrophysics Data System (ADS)
Namazi, Hamidreza; Kulish, Vladimir V.; Akrami, Amin
2016-05-01
One of the major challenges in vision research is to analyze the effect of visual stimuli on human vision. However, no relationship has been yet discovered between the structure of the visual stimulus, and the structure of fixational eye movements. This study reveals the plasticity of human fixational eye movements in relation to the ‘complex’ visual stimulus. We demonstrated that the fractal temporal structure of visual dynamics shifts towards the fractal dynamics of the visual stimulus (image). The results showed that images with higher complexity (higher fractality) cause fixational eye movements with lower fractality. Considering the brain, as the main part of nervous system that is engaged in eye movements, we analyzed the governed Electroencephalogram (EEG) signal during fixation. We have found out that there is a coupling between fractality of image, EEG and fixational eye movements. The capability observed in this research can be further investigated and applied for treatment of different vision disorders.
USDA-ARS?s Scientific Manuscript database
Our objective was to identify candidate QTL that had a large effect on seed weight using a selective population through GWAS and fixation index analysis. A selective population was previously used for the identification of QTL in linkage analysis of bi-parental RIL populations in plant species, but ...
Fixation, transient landscape, and diffusion dilemma in stochastic evolutionary game dynamics
NASA Astrophysics Data System (ADS)
Zhou, Da; Qian, Hong
2011-09-01
Agent-based stochastic models for finite populations have recently received much attention in the game theory of evolutionary dynamics. Both the ultimate fixation and the pre-fixation transient behavior are important to a full understanding of the dynamics. In this paper, we study the transient dynamics of the well-mixed Moran process through constructing a landscape function. It is shown that the landscape playing a central theoretical “device” that integrates several lines of inquiries: the stable behavior of the replicator dynamics, the long-time fixation, and continuous diffusion approximation associated with asymptotically large population. Several issues relating to the transient dynamics are discussed: (i) multiple time scales phenomenon associated with intra- and inter-attractoral dynamics; (ii) discontinuous transition in stochastically stationary process akin to Maxwell construction in equilibrium statistical physics; and (iii) the dilemma diffusion approximation facing as a continuous approximation of the discrete evolutionary dynamics. It is found that rare events with exponentially small probabilities, corresponding to the uphill movements and barrier crossing in the landscape with multiple wells that are made possible by strong nonlinear dynamics, plays an important role in understanding the origin of the complexity in evolutionary, nonlinear biological systems.
NASA Astrophysics Data System (ADS)
Podbielska, Halina; Kasprzak, Henryk T.; Voloshin, Arkady S.; Pennig, Dietmar; von Bally, Gert
1992-08-01
The unilateral axially dynamic fixator (Orthofix) was mounted on a sheep tibial shaft. Three fixation modes: static, dynamic controlled, and dynamic free were examined by means of double exposure holographic interferometry. Simultaneously, the acceleration was measured by an accelerometer and displayed on the monitor together with loading characteristics. The first exposure was made before the acting force was applied to the tibia plateau. The second one after the moment when the acceleration wave started to propagate through the specimen. We stated that in the case of dynamization less torsion occurs at the fracture site. So far, we have not been able to determine any correlation between results of holographic and accelerometric measurements.
Task modulates functional connectivity networks in free viewing behavior.
Seidkhani, Hossein; Nikolaev, Andrey R; Meghanathan, Radha Nila; Pezeshk, Hamid; Masoudi-Nejad, Ali; van Leeuwen, Cees
2017-10-01
In free visual exploration, eye-movement is immediately followed by dynamic reconfiguration of brain functional connectivity. We studied the task-dependency of this process in a combined visual search-change detection experiment. Participants viewed two (nearly) same displays in succession. First time they had to find and remember multiple targets among distractors, so the ongoing task involved memory encoding. Second time they had to determine if a target had changed in orientation, so the ongoing task involved memory retrieval. From multichannel EEG recorded during 200 ms intervals time-locked to fixation onsets, we estimated the functional connectivity using a weighted phase lag index at the frequencies of theta, alpha, and beta bands, and derived global and local measures of the functional connectivity graphs. We found differences between both memory task conditions for several network measures, such as mean path length, radius, diameter, closeness and eccentricity, mainly in the alpha band. Both the local and the global measures indicated that encoding involved a more segregated mode of operation than retrieval. These differences arose immediately after fixation onset and persisted for the entire duration of the lambda complex, an evoked potential commonly associated with early visual perception. We concluded that encoding and retrieval differentially shape network configurations involved in early visual perception, affecting the way the visual input is processed at each fixation. These findings demonstrate that task requirements dynamically control the functional connectivity networks involved in early visual perception. Copyright © 2017 Elsevier Inc. All rights reserved.
Bodala, Indu P; Abbasi, Nida I; Yu Sun; Bezerianos, Anastasios; Al-Nashash, Hasan; Thakor, Nitish V
2017-07-01
Eye tracking offers a practical solution for monitoring cognitive performance in real world tasks. However, eye tracking in dynamic environments is difficult due to high spatial and temporal variation of stimuli, needing further and thorough investigation. In this paper, we study the possibility of developing a novel computer vision assisted eye tracking analysis by using fixations. Eye movement data is obtained from a long duration naturalistic driving experiment. Source invariant feature transform (SIFT) algorithm was implemented using VLFeat toolbox to identify multiple areas of interest (AOIs). A new measure called `fixation score' was defined to understand the dynamics of fixation position between the target AOI and the non target AOIs. Fixation score is maximum when the subjects focus on the target AOI and diminishes when they gaze at the non-target AOIs. Statistically significant negative correlation was found between fixation score and reaction time data (r =-0.2253 and p<;0.05). This implies that with vigilance decrement, the fixation score decreases due to visual attention shifting away from the target objects resulting in an increase in the reaction time.
Impaired Attentional Control in Pedophiles in a Sexual Distractor Task.
Jordan, Kirsten; Fromberger, Peter; von Herder, Jakob; Steinkrauss, Henrike; Nemetschek, Rebekka; Witzel, Joachim; Müller, Jürgen L
2016-01-01
Pedophilic disorder, a subtype of paraphilia, is defined as a recurrent sexual interest in prepubescent children, which is characterized by persistent thoughts, fantasies, urges, sexual arousal, or behavior. Besides a deviant sexual preference, sexual preoccupation was found to be a dynamic risk factor for reoffending. Thus, it is conceivable that sex offenders and especially sex offenders against children have difficulties to control their responses to sexual stimuli. In the current study pedophiles, forensic and non-forensic control subjects had to solve a cognitive task, while sexual distractors were presented simultaneously. This kind of task also requires control functions. Therefore, data were analyzed with respect to attentional control while comparing eye movements toward sexual distractors and toward the cognitive task. We were mainly interested in how early (fixation latency) and late (relative fixation time) attentional processes were allocated to both, the cognitive target stimuli and the sexual distractors. Pedophiles demonstrated significantly lower attentional control in the sexual distractor task than both control groups (non-pedophiles). They showed a shorter fixation latency and longer fixation time for sexual distractors than non-pedophiles. Furthermore, pedophiles demonstrated a longer fixation latency and shorter fixation time for cognitive target stimuli. For classification analyses, an attentional control index (ACI) was built, i.e., the difference between eye movements on cognitive target stimuli and sexual distractors. For the ACI of early attentional processes, i.e., fixation latency, a good classification between pedophiles and non-pedophiles was found. We assumed that the measured attentional control represents inhibitory executive functions, specifically interference control. Further studies should examine if low attentional control in pedophiles is due to low motivation to solve the task or rather to a lack of ability to control attention with respect to sexual and/or neutral distractors. Prospectively, this design could be useful to generate hypotheses about clinical important aspects of controllability, the capacity of self-control, and the severity of a paraphilic disorder.
Impaired Attentional Control in Pedophiles in a Sexual Distractor Task
Jordan, Kirsten; Fromberger, Peter; von Herder, Jakob; Steinkrauss, Henrike; Nemetschek, Rebekka; Witzel, Joachim; Müller, Jürgen L.
2016-01-01
Pedophilic disorder, a subtype of paraphilia, is defined as a recurrent sexual interest in prepubescent children, which is characterized by persistent thoughts, fantasies, urges, sexual arousal, or behavior. Besides a deviant sexual preference, sexual preoccupation was found to be a dynamic risk factor for reoffending. Thus, it is conceivable that sex offenders and especially sex offenders against children have difficulties to control their responses to sexual stimuli. In the current study pedophiles, forensic and non-forensic control subjects had to solve a cognitive task, while sexual distractors were presented simultaneously. This kind of task also requires control functions. Therefore, data were analyzed with respect to attentional control while comparing eye movements toward sexual distractors and toward the cognitive task. We were mainly interested in how early (fixation latency) and late (relative fixation time) attentional processes were allocated to both, the cognitive target stimuli and the sexual distractors. Pedophiles demonstrated significantly lower attentional control in the sexual distractor task than both control groups (non-pedophiles). They showed a shorter fixation latency and longer fixation time for sexual distractors than non-pedophiles. Furthermore, pedophiles demonstrated a longer fixation latency and shorter fixation time for cognitive target stimuli. For classification analyses, an attentional control index (ACI) was built, i.e., the difference between eye movements on cognitive target stimuli and sexual distractors. For the ACI of early attentional processes, i.e., fixation latency, a good classification between pedophiles and non-pedophiles was found. We assumed that the measured attentional control represents inhibitory executive functions, specifically interference control. Further studies should examine if low attentional control in pedophiles is due to low motivation to solve the task or rather to a lack of ability to control attention with respect to sexual and/or neutral distractors. Prospectively, this design could be useful to generate hypotheses about clinical important aspects of controllability, the capacity of self-control, and the severity of a paraphilic disorder. PMID:27994559
Fixational eye movement: a negligible source of dynamic aberration.
Mecê, Pedro; Jarosz, Jessica; Conan, Jean-Marc; Petit, Cyril; Grieve, Kate; Paques, Michel; Meimon, Serge
2018-02-01
To evaluate the contribution of fixational eye movements to dynamic aberration, 50 healthy eyes were examined with an original custom-built Shack-Hartmann aberrometer, running at a temporal frequency of 236Hz, with 22 lenslets across a 5mm pupil, synchronized with a 236Hz pupil tracker. A comparison of the dynamic behavior of the first 21 Zernike modes (starting from defocus) with and without digital pupil stabilization, on a 3.4s sequence between blinks, showed that the contribution of fixational eye movements to dynamic aberration is negligible. Therefore we highlighted the fact that a pupil tracker coupled to an Adaptive Optics Ophthalmoscope is not essential to achieve diffraction-limited resolution.
Design Fixation in the Wild: Design Environments and Their Influence on Fixation
ERIC Educational Resources Information Center
Youmans, Robert J.
2011-01-01
Many studies of design fixation ask designers to work in controlled laboratory or classroom environments, but innovative design work frequently occurs in dynamic, social environments. The two studies reviewed in this paper investigated how three independent variables likely to be present in many design environments affect design fixation. The…
Wilkinson, Nicholas M.; Metta, Giorgio
2014-01-01
Visual scan paths exhibit complex, stochastic dynamics. Even during visual fixation, the eye is in constant motion. Fixational drift and tremor are thought to reflect fluctuations in the persistent neural activity of neural integrators in the oculomotor brainstem, which integrate sequences of transient saccadic velocity signals into a short term memory of eye position. Despite intensive research and much progress, the precise mechanisms by which oculomotor posture is maintained remain elusive. Drift exhibits a stochastic statistical profile which has been modeled using random walk formalisms. Tremor is widely dismissed as noise. Here we focus on the dynamical profile of fixational tremor, and argue that tremor may be a signal which usefully reflects the workings of oculomotor postural control. We identify signatures reminiscent of a certain flavor of transient neurodynamics; toric traveling waves which rotate around a central phase singularity. Spiral waves play an organizational role in dynamical systems at many scales throughout nature, though their potential functional role in brain activity remains a matter of educated speculation. Spiral waves have a repertoire of functionally interesting dynamical properties, including persistence, which suggest that they could in theory contribute to persistent neural activity in the oculomotor postural control system. Whilst speculative, the singularity hypothesis of oculomotor postural control implies testable predictions, and could provide the beginnings of an integrated dynamical framework for eye movements across scales. PMID:24616670
Management of complex femoral nonunion with monorail external fixator: A prospective study.
Agrawal, Hemendra Kumar; Garg, Mohit; Singh, Balvinder; Jaiman, Ashish; Khatkar, Vipin; Khare, Shailender; Batra, Sumit; Sharma, Vinod Kumar
2016-01-01
To evaluate 30 patients who underwent distraction osteogenesis with monorail external fixator for complex femoral nonunion. Complex femoral nonunion includes infective non-union, gap nonunion, and limb-length discrepancy secondary to traumatic bone loss, which needs specialized treatment to ensure the functional integrity of femoral bone. 30 patients, including 28 male and 2 female (aged 22-62 years) patients, underwent surgical debridement followed by bone transport with monorail fixator. The lengthening index, radiographic consolidation index, functional status, bone healing, and various problems, obstacles, and complications encountered during the treatment were assessed. Patients underwent a mean of 2.2 (range 1-4) surgeries before presentation. The mean bone defect after surgical debridement was 5.83 cm (range 2-16 cm). The mean treatment duration was 204.7 days (range 113-543 days). The mean lengthening index was 13.06 days/cm with range from 12 to 16 days/cm. Mean maturation index was 23.51 days/cm with range from 17 to 45.5 days/cm. In our study, bone result was excellent in 17, good in 9, fair in 3, and poor in 1 patient. In our study functional outcome is excellent in 9 [30%], good in 14 [46.67%], fair in 5, and poor in 2 patients. In our study, we encountered 34 problems, 17 obstacles, and 8 complications. We concluded that monorail external fixator is an effective treatment option for complex nonunion femoral shaft fracture and its functional outcome is comparable with any other treatment options. Lack of complications and its effectiveness makes monorail external fixator the treatment of choice for complex nonunion femoral shaft.
The influence of object shape and center of mass on grasp and gaze
Desanghere, Loni; Marotta, Jonathan J.
2015-01-01
Recent experiments examining where participants look when grasping an object found that fixations favor the eventual index finger landing position on the object. Even though the act of picking up an object must involve complex high-level computations such as the visual analysis of object contours, surface properties, knowledge of an object’s function and center of mass (COM) location, these investigations have generally used simple symmetrical objects – where COM and horizontal midline overlap. Less research has been aimed at looking at how variations in object properties, such as differences in curvature and changes in COM location, affect visual and motor control. The purpose of this study was to examine grasp and fixation locations when grasping objects whose COM was positioned to the left or right of the objects horizontal midline (Experiment 1) and objects whose COM was moved progressively further from the midline of the objects based on the alteration of the object’s shape (Experiment 2). Results from Experiment 1 showed that object COM position influenced fixation locations and grasp locations differently, with fixations not as tightly linked to index finger grasp locations as was previously reported with symmetrical objects. Fixation positions were also found to be more central on the non-symmetrical objects. This difference in gaze position may provide a more holistic view, which would allow both index finger and thumb positions to be monitored while grasping. Finally, manipulations of COM distance (Experiment 2) exerted marked effects on the visual analysis of the objects when compared to its influence on grasp locations, with fixation locations more sensitive to these manipulations. Together, these findings demonstrate how object features differentially influence gaze vs. grasp positions during object interaction. PMID:26528207
Less-invasive stabilization of rib fractures by intramedullary fixation: a biomechanical evaluation.
Bottlang, Michael; Helzel, Inga; Long, William; Fitzpatrick, Daniel; Madey, Steven
2010-05-01
This study evaluated intramedullary fixation of rib fractures with Kirschner wires and novel ribs splints. We hypothesized that rib splints can provide equivalent fixation strength while avoiding complications associated with Kirschner wires, namely wire migration and cutout. The durability, strength, and failure modes of rib fracture fixation with Kirschner wires and rib splints were evaluated in 22 paired human ribs. First, intact ribs were loaded to failure to determine their strength. After fracture fixation with Kirschner wires and rib splints, fixation constructs were dynamically loaded to 360,000 cycles at five times the respiratory load to determine their durability. Finally, constructs were loaded to failure to determine residual strength and failure modes. All constructs sustained dynamic loading without failure. Dynamic loading caused three times more subsidence in Kirschner wire constructs (1.2 mm +/- 1.4 mm) than in rib splint constructs (0.4 mm +/- 0.2 mm, p = 0.09). After dynamic loading, rib splint constructs remained 48% stronger than Kirschner wire constructs (p = 0.001). Five of 11 Kirschner wire constructs failed catastrophically by cutting through the medial cortex, leading to complete loss of stability and wire migration through the lateral cortex. The remaining six constructs failed by wire bending. Rib splint constructs failed by development of fracture lines along the superior and interior cortices. No splint construct failed catastrophically, and all splint constructs retained functional reduction and fixation. Because of their superior strength and absence of catastrophic failure mode, rib splints can serve as an attractive alternative to Kirschner wires for intramedullary stabilization of rib fractures, especially in the case of posterior rib fractures where access for plating is limited.
Dynamic Distraction External Fixation for Contracture of the Metacarpophalangeal Joint.
Seigerman, Daniel A; Tan, Virak
2015-12-01
Metacarpophalangeal (MP) joint contractures are common after traumatic injury, and can be difficult to manage. After surgical capsulectomy, it remains challenging to maintain motion that was obtained at the time of surgery. Our group uses a novel, prefabricated digital external fixator to provide both distraction, and motion therapy across the MP joint after surgical treatment of MP contracture. The purpose of this technique is to demonstrate the effectiveness of an adjunctive dynamic distraction external fixator for the maintenance of joint motion after surgical treatment of MP contractures of the border digits.
Laflamme, Mélissa; Belzile, Etienne L; Bédard, Luc; van den Bekerom, Michel P J; Glazebrook, Mark; Pelet, Stéphane
2015-05-01
To compare the clinical and radiographic outcome after stabilization of an acute syndesmosis rupture with either a static implant (a 3.5-mm metallic screw through 4 cortices) or a dynamic device (TightRope; Arthrex). Multicenter randomized double-blind controlled trial. Study realized in 5 trauma centers (2 level 1 and 3 level 2) in 2 countries. Seventy subjects admitted for an acute ankle syndesmosis rupture entered the study and were randomized into 2 groups (dynamic fixation = 34 and static fixation = 36). The 2 groups were similar regarding demographic, social, and surgical data. Sixty-five patients (dynamic = 33 and static = 32) completed the study and were available for analysis. Syndesmosis fixation in the static group was realized with a 4 cortices 3.5-mm cortical screw (Synthes) and in the dynamic group with 1 TightRope (Arthrex). Standardized rehabilitation process for the 2 groups: no weight bearing in a cast for 6 weeks and then rehabilitation without protection. Olerud-Molander score. Subjects with dynamic fixation achieved better clinical performances as described with the Olerud-Molander scores at 3 (68.8 vs. 60.2, P = 0.067), 6 (84.2 vs. 76.8, P = 0.082), and 12 months (93.3 vs. 87.6, P = 0.046). We also observed higher American Orthopaedic Foot and Ankle Society scores at 3 months (78.6 vs. 70.6, P = 0.016), but these were not significant at 6 (87.1 vs. 83.8, P = 0.26) or 12 months (93.1 vs. 89.9, P = 0.26). Implant failure was higher in the screw group (36.1% vs. 0%, P < 0.05). Loss of reduction was observed in 4 cases in the static screw group (11.1% vs. 0%, P = 0.06). Dynamic fixation of acute ankle syndesmosis rupture with a dynamic device seems to result in better clinical and radiographic outcomes. The implant offers adequate syndesmotic stabilization without failure or loss of reduction, and the reoperation rate is significantly lower than with conventional screw fixation. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.
Galla, Tobias
2018-01-01
Using a stochastic model, we investigate the probability of fixation, and the average time taken to achieve fixation, of a mutant in a population of wild-types. We do this in a context where the environment in which the competition takes place is subject to stochastic change. Our model takes into account interactions which can involve multiple participants. That is, the participants take part in multiplayer games. We find that under certain circumstances, there are environmental switching dynamics which minimize the time that it takes for the mutants to fixate. To analyse the dynamics more closely, we develop a method by which to calculate the sojourn times for general birth–death processes in fluctuating environments. PMID:29657810
NASA Astrophysics Data System (ADS)
Baron, Joseph W.; Galla, Tobias
2018-03-01
Using a stochastic model, we investigate the probability of fixation, and the average time taken to achieve fixation, of a mutant in a population of wild-types. We do this in a context where the environment in which the competition takes place is subject to stochastic change. Our model takes into account interactions which can involve multiple participants. That is, the participants take part in multiplayer games. We find that under certain circumstances, there are environmental switching dynamics which minimize the time that it takes for the mutants to fixate. To analyse the dynamics more closely, we develop a method by which to calculate the sojourn times for general birth-death processes in fluctuating environments.
Glatt, Vaida; Bartnikowski, Nicole; Quirk, Nicholas; Schuetz, Michael; Evans, Christopher
2016-04-20
Reverse dynamization is a technology for enhancing the healing of osseous defects. With use of an external fixator, the axial stiffness across the defect is initially set low and subsequently increased. The purpose of the study described in this paper was to explore the efficacy of reverse dynamization under different conditions. Rat femoral defects were stabilized with external fixators that allowed the stiffness to be modulated on living animals. Recombinant human bone morphogenetic protein-2 (rhBMP-2) was implanted into the defects on a collagen sponge. Following a dose-response experiment, 5.5 μg of rhBMP-2 was placed into the defect under conditions of very low (25.4-N/mm), low (114-N/mm), medium (185-N/mm), or high (254-N/mm) stiffness. Reverse dynamization was evaluated with 2 different starting stiffnesses: low (114 N/mm) and very low (25.4 N/mm). In both cases, high stiffness (254 N/mm) was imposed after 2 weeks. Healing was assessed with radiographs, micro-computed tomography (μCT), histological analysis, and mechanical testing. In the absence of dynamization, the medium-stiffness fixators provided the best healing. Reverse dynamization starting with very low stiffness was detrimental to healing. However, with low initial stiffness, reverse dynamization considerably improved healing with minimal residual cartilage, enhanced cortication, increased mechanical strength, and smaller callus. Histological analysis suggested that, in all cases, healing provoked by rhBMP-2 occurred by endochondral ossification. These data confirm the potential utility of reverse dynamization as a way of improving bone healing but indicate that the stiffness parameters need to be selected carefully. Reverse dynamization may reduce the amount of rhBMP-2 needed to induce healing of recalcitrant osseous lesions, reduce the time to union, and decrease the need for prolonged external fixation. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.
Guo, Qunfeng; Wang, Liang; Lu, Xuhua; Guo, Xiang; Ni, Bin
2017-04-01
To evaluate differences in radiologic and functional outcomes between C1-C2 posterior temporary fixation (PTF) and cephalocervicothoracic cast fixation for type III odontoid fractures. Data from 13 patients who underwent PTF and 13 cases who underwent cephalocervicothoracic cast fixation due to fresh type III odontoid fractures were reviewed retrospectively. All patients with fracture healing underwent a functional computed tomography scan at the final follow-up to evaluate the range of motion in C1-C2 rotation. Functional outcomes were evaluated in the form of visual analog scale for neck pain, neck stiffness, patient satisfaction, and Neck Disability Index. The outcomes were compared between the 2 groups. At the final follow up, all 26 patients achieved healing of their fractures. There were no complications associated with either treatment. The left-to-right ranges of motion of C1-C2 rotation were 41.9° ± 11.9° in the PTF group and 43.5° ± 12.0° in the cephalocervicothoracic cast fixation group. There was no statistical difference between the 2 groups regarding the C1-C2 rotation angle (P > 0.05). There also were no significant differences between 2 groups in functional outcomes evaluated by visual analog scale for neck pain, neck stiffness, Neck Disability Index, and patient satisfaction (all P > 0.05). The outcomes of PTF and cephalocervicothoracic cast fixation were comparable in the treatment of type III odontoid fractures. For type III odontoid fractures that cannot be managed by nonoperative fixation or anterior screw fixation, PTF may be the treatment of choice, because it spares the motion of the C1-C2 complex. Copyright © 2016 Elsevier Inc. All rights reserved.
Andersson, Richard; Larsson, Linnea; Holmqvist, Kenneth; Stridh, Martin; Nyström, Marcus
2017-04-01
Almost all eye-movement researchers use algorithms to parse raw data and detect distinct types of eye movement events, such as fixations, saccades, and pursuit, and then base their results on these. Surprisingly, these algorithms are rarely evaluated. We evaluated the classifications of ten eye-movement event detection algorithms, on data from an SMI HiSpeed 1250 system, and compared them to manual ratings of two human experts. The evaluation focused on fixations, saccades, and post-saccadic oscillations. The evaluation used both event duration parameters, and sample-by-sample comparisons to rank the algorithms. The resulting event durations varied substantially as a function of what algorithm was used. This evaluation differed from previous evaluations by considering a relatively large set of algorithms, multiple events, and data from both static and dynamic stimuli. The main conclusion is that current detectors of only fixations and saccades work reasonably well for static stimuli, but barely better than chance for dynamic stimuli. Differing results across evaluation methods make it difficult to select one winner for fixation detection. For saccade detection, however, the algorithm by Larsson, Nyström and Stridh (IEEE Transaction on Biomedical Engineering, 60(9):2484-2493,2013) outperforms all algorithms in data from both static and dynamic stimuli. The data also show how improperly selected algorithms applied to dynamic data misestimate fixation and saccade properties.
Dobran, Mauro; Esposito, Domenico Paolo; Gladi, Maurizio; Scerrati, Massimo; Iacoangeli, Maurizio
2018-01-01
Study Design Retrospective study with long-term follow-up. Purpose To evaluate the long-term incidence of adjacent segment degeneration (ASD) and clinical outcomes in a consecutive series of patients who underwent spinal decompression associated with dynamic or hybrid stabilization with a Flex+TM stabilization system (SpineVision, Antony, France) for lumbar spinal stenosis. Overview of Literature The incidence of ASD and clinical outcomes following dynamic or hybrid stabilization with the Flex+TM system used for lumbar spinal stenosis have not been well investigated. Methods Twenty-one patients with lumbar stenosis and probable post-decompressive spinal instability underwent decompressive laminectomy followed by spinal stabilization using the Flex+TM stabilization system. The indication for a mono-level dynamic stabilization was a preoperative magnetic resonance imaging (MRI) demonstrating evidence of severe disc disease associated with severe spinal stenosis. The hybrid stabilization (rigid-dynamic) system was used for multilevel laminectomies with associated initial degenerative scoliosis, first-grade spondylolisthesis, or rostral pathology. Results The improvement in Visual Analog Scale and Oswestry Disability Index scores at follow-up were statistically significant (p<0.0001 and p<0.0001, respectively). At the 5–8-year follow-up, clinical examination, MRI, and X-ray findings showed an ASD complication with pain and disability in one of 21 patients. The clinical outcomes were similar in patients treated with dynamic or hybrid fixation. Conclusions Patients treated with laminectomy and Flex+TM stabilization presented a satisfactory clinical outcome after 5–8 years of follow-up, and ASD incidence in our series was 4.76% (one patient out of 21). We are aware that this is a small series, but our long-term follow-up may be sufficient to contribute to the expanding body of literature on the development of symptomatic ASD associated with dynamic or hybrid fixation. PMID:29713407
Fixation of a human rib by an intramedullary telescoping splint anchored by bone cement.
Liovic, Petar; Šutalo, Ilija D; Marasco, Silvana F
2016-09-01
A novel concept for rib fixation is presented that involves the use of a bioresorbable polymer intramedullary telescoping splint. Bone cement is used to anchor each end of the splint inside the medullary canal on each side of the fracture site. In this manner, rib fixation is achieved without fixation device protrusion from the rib, making the splint completely intramedullary. Finite element analysis is used to demonstrate that such a splint/cement composite can preserve rib fixation subjected to cough-intensity force loadings. Computational fluid dynamics and porcine rib experiments were used to study the anchor formation process required to complete the fixation.
Horsager, Kristian; Kaptein, Bart L; Rømer, Lone; Jørgensen, Peter B; Stilling, Maiken
2017-06-01
Background and purpose - Implant inducible micromotions have been suggested to reflect the quality of the fixation interface. We investigated the usability of dynamic RSA for evaluation of inducible micromotions of the Oxford Unicompartmental Knee Arthroplasty (UKA) tibial component, and evaluated factors that have been suggested to compromise the fixation, such as fixation method, component alignment, and radiolucent lines (RLLs). Patients and methods - 15 patients (12 men) with a mean age of 69 (55-86) years, with an Oxford UKA (7 cemented), were studied after a mean time in situ of 4.4 (3.6-5.1) years. 4 had tibial RLLs. Each patient was recorded with dynamic RSA (10 frames/second) during a step-up/step-down motion. Inducible micromotions were calculated for the tibial component with respect to the tibia bone. Postoperative component alignment was measured with model-based RSA and RLLs were measured on screened radiographs. Results - All tibial components showed inducible micromotions as a function of the step-cycle motion with a mean subsidence of up to -0.06 mm (95% CI: -0.10 to -0.03). Tibial component inducible micromotions were similar for cemented fixation and cementless fixation. Patients with tibial RLLs had 0.5° (95% CI: 0.18-0.81) greater inducible medio-lateral tilt of the tibial component. There was a correlation between postoperative posterior slope of the tibial plateau and inducible anterior-posterior tilt. Interpretation - All patients had inducible micromotions of the tibial component during step-cycle motion. RLLs and a high posterior slope increased the magnitude of inducible micromotions. This suggests that dynamic RSA is a valuable clinical tool for the evaluation of functional implant fixation.
NASA Astrophysics Data System (ADS)
Thomas, R. Q.; Williams, M.
2014-04-01
Carbon (C) and nitrogen (N) cycles are coupled in terrestrial ecosystems through multiple processes including photosynthesis, tissue allocation, respiration, N fixation, N uptake, and decomposition of litter and soil organic matter. Capturing the constraint of N on terrestrial C uptake and storage has been a focus of the Earth System modelling community. However there is little understanding of the trade-offs and sensitivities of allocating C and N to different tissues in order to optimize the productivity of plants. Here we describe a new, simple model of ecosystem C-N cycling and interactions (ACONITE), that builds on theory related to plant economics in order to predict key ecosystem properties (leaf area index, leaf C : N, N fixation, and plant C use efficiency) using emergent constraints provided by marginal returns on investment for C and/or N allocation. We simulated and evaluated steady-state ecosystem stocks and fluxes in three different forest ecosystems types (tropical evergreen, temperate deciduous, and temperate evergreen). Leaf C : N differed among the three ecosystem types (temperate deciduous < tropical evergreen < temperature evergreen), a result that compared well to observations from a global database describing plant traits. Gross primary productivity (GPP) and net primary productivity (NPP) estimates compared well to observed fluxes at the simulation sites. Simulated N fixation at steady-state, calculated based on relative demand for N and the marginal return on C investment to acquire N, was an order of magnitude higher in the tropical forest than in the temperate forest, consistent with observations. A sensitivity analysis revealed that parameterization of the relationship between leaf N and leaf respiration had the largest influence on leaf area index and leaf C : N. Also, a widely used linear leaf N-respiration relationship did not yield a realistic leaf C : N, while a more recently reported non-linear relationship performed better. A parameter governing how photosynthesis scales with day length had the largest influence on total vegetation C, GPP, and NPP. Multiple parameters associated with photosynthesis, respiration, and N uptake influenced the rate of N fixation. Overall, our ability to constrain leaf area index and have spatially and temporally variable leaf C : N helps address challenges for ecosystem and Earth System models. Furthermore, the simple approach with emergent properties based on coupled C-N dynamics has potential for use in research that uses data-assimilation methods to integrate data on both the C and N cycles to improve C flux forecasts.
NASA Astrophysics Data System (ADS)
Thomas, R. Q.; Williams, M.
2014-09-01
Carbon (C) and nitrogen (N) cycles are coupled in terrestrial ecosystems through multiple processes including photosynthesis, tissue allocation, respiration, N fixation, N uptake, and decomposition of litter and soil organic matter. Capturing the constraint of N on terrestrial C uptake and storage has been a focus of the Earth System Modeling community. However, there is little understanding of the trade-offs and sensitivities of allocating C and N to different tissues in order to optimize the productivity of plants. Here we describe a new, simple model of ecosystem C-N cycling and interactions (ACONITE), that builds on theory related to plant economics in order to predict key ecosystem properties (leaf area index, leaf C : N, N fixation, and plant C use efficiency) based on the outcome of assessments of the marginal change in net C or N uptake associated with a change in allocation of C or N to plant tissues. We simulated and evaluated steady-state ecosystem stocks and fluxes in three different forest ecosystems types (tropical evergreen, temperate deciduous, and temperate evergreen). Leaf C : N differed among the three ecosystem types (temperate deciduous < tropical evergreen < temperature evergreen), a result that compared well to observations from a global database describing plant traits. Gross primary productivity (GPP) and net primary productivity (NPP) estimates compared well to observed fluxes at the simulation sites. Simulated N fixation at steady-state, calculated based on relative demand for N and the marginal return on C investment to acquire N, was an order of magnitude higher in the tropical forest than in the temperate forest, consistent with observations. A sensitivity analysis revealed that parameterization of the relationship between leaf N and leaf respiration had the largest influence on leaf area index and leaf C : N. A parameter governing how photosynthesis scales with day length had the largest influence on total vegetation C, GPP, and NPP. Multiple parameters associated with photosynthesis, respiration, and N uptake influenced the rate of N fixation. Overall, our ability to constrain leaf area index and allow spatially and temporally variable leaf C : N can help address challenges simulating these properties in ecosystem and Earth System models. Furthermore, the simple approach with emergent properties based on coupled C-N dynamics has potential for use in research that uses data-assimilation methods to integrate data on both the C and N cycles to improve C flux forecasts.
Wang, Yicun; Jiang, Hui; Deng, Zhantao; Jin, Jiewen; Meng, Jia; Wang, Jun; Zhao, Jianning; Sun, Guojing; Qian, Hongbo
2017-01-01
To compare the salvage rate and complication between internal fixation and external fixation in patients with small bone defects caused by chronic infectious osteomyelitis debridement. 125 patients with chronic infectious osteomyelitis of tibia fracture who underwent multiple irrigation, debridement procedure, and local/systemic antibiotics were enrolled. Bone defects, which were less than 4 cm, were treated with bone grafting using either internal fixation or monolateral external fixation. 12-month follow-up was conducted with an interval of 3 months to evaluate union of bone defect. Patients who underwent monolateral external fixation had higher body mass index and fasting blood glucose, longer time since injury, and larger bone defect compared with internal fixation. No significant difference was observed in incidence of complications (23.5% versus 19.3%), surgery time (156 ± 23 minutes versus 162 ± 21 minutes), and time to union (11.1 ± 3.0 months versus 10.9 ± 3.1 months) between external fixation and internal fixation. Internal fixation had no significant influence on the occurrence of postoperation complications after multivariate adjustment when compared with external fixation. Furthermore, patients who underwent internal fixation experienced higher level of daily living scales and lower level of anxiety. It was relatively safe to use internal fixation for stabilization in osteomyelitis patients whose bone defects were less than 4 cm and infection was well controlled.
Wang, Yicun; Jiang, Hui; Deng, Zhantao; Meng, Jia; Wang, Jun
2017-01-01
Background To compare the salvage rate and complication between internal fixation and external fixation in patients with small bone defects caused by chronic infectious osteomyelitis debridement. Methods 125 patients with chronic infectious osteomyelitis of tibia fracture who underwent multiple irrigation, debridement procedure, and local/systemic antibiotics were enrolled. Bone defects, which were less than 4 cm, were treated with bone grafting using either internal fixation or monolateral external fixation. 12-month follow-up was conducted with an interval of 3 months to evaluate union of bone defect. Results Patients who underwent monolateral external fixation had higher body mass index and fasting blood glucose, longer time since injury, and larger bone defect compared with internal fixation. No significant difference was observed in incidence of complications (23.5% versus 19.3%), surgery time (156 ± 23 minutes versus 162 ± 21 minutes), and time to union (11.1 ± 3.0 months versus 10.9 ± 3.1 months) between external fixation and internal fixation. Internal fixation had no significant influence on the occurrence of postoperation complications after multivariate adjustment when compared with external fixation. Furthermore, patients who underwent internal fixation experienced higher level of daily living scales and lower level of anxiety. Conclusions It was relatively safe to use internal fixation for stabilization in osteomyelitis patients whose bone defects were less than 4 cm and infection was well controlled. PMID:29333448
Glatt, Vaida; Bartnikowski, Nicole; Quirk, Nicholas; Schuetz, Michael; Evans, Christopher
2016-01-01
Background: Reverse dynamization is a technology for enhancing the healing of osseous defects. With use of an external fixator, the axial stiffness across the defect is initially set low and subsequently increased. The purpose of the study described in this paper was to explore the efficacy of reverse dynamization under different conditions. Methods: Rat femoral defects were stabilized with external fixators that allowed the stiffness to be modulated on living animals. Recombinant human bone morphogenetic protein-2 (rhBMP-2) was implanted into the defects on a collagen sponge. Following a dose-response experiment, 5.5 μg of rhBMP-2 was placed into the defect under conditions of very low (25.4-N/mm), low (114-N/mm), medium (185-N/mm), or high (254-N/mm) stiffness. Reverse dynamization was evaluated with 2 different starting stiffnesses: low (114 N/mm) and very low (25.4 N/mm). In both cases, high stiffness (254 N/mm) was imposed after 2 weeks. Healing was assessed with radiographs, micro-computed tomography (μCT), histological analysis, and mechanical testing. Results: In the absence of dynamization, the medium-stiffness fixators provided the best healing. Reverse dynamization starting with very low stiffness was detrimental to healing. However, with low initial stiffness, reverse dynamization considerably improved healing with minimal residual cartilage, enhanced cortication, increased mechanical strength, and smaller callus. Histological analysis suggested that, in all cases, healing provoked by rhBMP-2 occurred by endochondral ossification. Conclusions: These data confirm the potential utility of reverse dynamization as a way of improving bone healing but indicate that the stiffness parameters need to be selected carefully. Clinical Relevance: Reverse dynamization may reduce the amount of rhBMP-2 needed to induce healing of recalcitrant osseous lesions, reduce the time to union, and decrease the need for prolonged external fixation. PMID:27098327
A SYMMETRY OF FIXATION TIMES IN EVOULTIONARY DYNAMICS
TAYLOR, CHRISTINE; IWASA, YOH; NOWAK, MARTIN A.
2010-01-01
In this paper, we show that for evolutionary dynamics between two types that can be described by a Moran process, the conditional fixation time of either type is the same irrespective of the selective scenario. With frequency dependent selection between two strategies A and B of an evolutionary game, regardless of whether A dominates B, A and B are best replies to themselves, or A and B are best replies to each other, the conditional fixation times of a single A and a single B mutant are identical. This does not hold for Wright-Fisher models, nor when the mutants start from multiple copies. PMID:16890959
Tekin, Ali Çağrı; Çabuk, Haluk; Dedeoğlu, Süleyman Semih; Saygılı, Mehmet Selçuk; Adaş, Müjdat; Esenyel, Cem Zeki; Büyükkurt, Cem Dinçay; Tonbul, Murat
2016-03-22
To present the functional and radiological results and evaluate the effectiveness of a computer-assisted external fixator (spider frame) in patients with lower extremity shortness and deformity. The study comprised 17 patients (14 male, 3 female) who were treated for lower extremity long bone deformity and shortness between 2012 and 2015 using a spider frame. The procedure's level of difficulty was determined preoperatively using the Paley Scale. Postoperatively, the results for the patients who underwent tibial operations were evaluated using the Paley criteria modified by ASAMI, and the results for the patients who underwent femoral operations were evaluated according to the Paley scoring system. The evaluations were made by calculating the External Fixator and Distraction indexes. The mean age of the patients was 24.58 years (range, 5-51 years). The spider frame was applied to the femur in 10 patients and to the tibia in seven. The mean follow-up period was 15 months (range, 6-31 months) from the operation day, and the mean amount of lengthening was 3.0 cm (range, 1-6 cm). The mean duration of fixator application was 202.7 days (range, 104-300 days). The mean External Fixator Index was 98 days/cm (range, 42-265 days/cm). The mean Distraction Index was 10.49 days/cm (range, 10-14 days/cm). The computer-assisted external fixator system (spider frame) achieves single-stage correction in cases of both deformity and shortness. The system can be applied easily, and because of its high-tech software, it offers the possibility of postoperative treatment of the deformity.
Zielinski, Stephanie M; Keijsers, Noël L; Praet, Stephan F E; Heetveld, Martin J; Bhandari, Mohit; Wilssens, Jean Pierre; Patka, Peter; Van Lieshout, Esther M M
2014-12-01
To determine patient independency, health-related and disease-specific quality of life (QOL), gait pattern, and muscle strength in patients after salvage arthroplasty for failed internal fixation of a femoral neck fracture. Secondary cohort study to a randomized controlled trial. Multicenter trial in the Netherlands, including 14 academic and nonacademic hospitals. Patients after salvage arthroplasty for failed internal fixation of a femoral neck fracture were studied. A comparison was made with patients who healed uneventfully after internal fixation. None (observatory study). Patient characteristics, SF-12, and Western Ontario McMaster osteoarthritis index scores were collected. Gait parameters were measured using plantar pressure measurement. Maximum isometric forces of the hip muscles were measured using a handheld dynamometer. Differences between the fractured and contralateral leg were calculated. Groups were compared using univariate analysis. Of 248 internal fixation patients (median age, 72 years), salvage arthroplasty was performed in 68 patients (27%). Salvage arthroplasty patients had a significantly lower Western Ontario McMaster osteoarthritis index score (median, 73 vs. 90; P = 0.016) than patients who healed uneventfully after internal fixation. Health-related QOL (SF-12) and patient independency did not differ significantly between the groups. Gait analysis showed a significantly impaired progression of the center of pressure in the salvage surgery patients (median ratio, -8.9 vs. 0.4, P = 0.013) and a significant greater loss of abduction strength (median, -25.4 vs. -20.4 N, P = 0.025). Despite a similar level of dependency and QOL, salvage arthroplasty patients have inferior functional outcome than patients who heal after internal fixation of a femoral neck fracture. Therapeutic level III.
Live interaction distinctively shapes social gaze dynamics in rhesus macaques.
Dal Monte, Olga; Piva, Matthew; Morris, Jason A; Chang, Steve W C
2016-10-01
The dynamic interaction of gaze between individuals is a hallmark of social cognition. However, very few studies have examined social gaze dynamics after mutual eye contact during real-time interactions. We used a highly quantifiable paradigm to assess social gaze dynamics between pairs of monkeys and modeled these dynamics using an exponential decay function to investigate sustained attention after mutual eye contact. When monkeys were interacting with real partners compared with static images and movies of the same monkeys, we found a significant increase in the proportion of fixations to the eyes and a smaller dispersion of fixations around the eyes, indicating enhanced focal attention to the eye region. Notably, dominance and familiarity between the interacting pairs induced separable components of gaze dynamics that were unique to live interactions. Gaze dynamics of dominant monkeys after mutual eye contact were associated with a greater number of fixations to the eyes, whereas those of familiar pairs were associated with a faster rate of decrease in this eye-directed attention. Our findings endorse the notion that certain key aspects of social cognition are only captured during interactive social contexts and dependent on the elapsed time relative to socially meaningful events. Copyright © 2016 the American Physiological Society.
Live interaction distinctively shapes social gaze dynamics in rhesus macaques
Piva, Matthew; Morris, Jason A.; Chang, Steve W. C.
2016-01-01
The dynamic interaction of gaze between individuals is a hallmark of social cognition. However, very few studies have examined social gaze dynamics after mutual eye contact during real-time interactions. We used a highly quantifiable paradigm to assess social gaze dynamics between pairs of monkeys and modeled these dynamics using an exponential decay function to investigate sustained attention after mutual eye contact. When monkeys were interacting with real partners compared with static images and movies of the same monkeys, we found a significant increase in the proportion of fixations to the eyes and a smaller dispersion of fixations around the eyes, indicating enhanced focal attention to the eye region. Notably, dominance and familiarity between the interacting pairs induced separable components of gaze dynamics that were unique to live interactions. Gaze dynamics of dominant monkeys after mutual eye contact were associated with a greater number of fixations to the eyes, whereas those of familiar pairs were associated with a faster rate of decrease in this eye-directed attention. Our findings endorse the notion that certain key aspects of social cognition are only captured during interactive social contexts and dependent on the elapsed time relative to socially meaningful events. PMID:27486105
Dargel, Jens; Koebke, Jürgen; Brüggemann, Gert-Peter; Pennig, Dietmar; Schmidt-Wiethoff, Rüdiger
2009-10-01
This study investigates the influence of various femoral anterior cruciate ligament graft fixation methods on the amount of tension degradation and the initial fixation strength after cyclic flexion-extension loading in a porcine knee model. One hundred twenty porcine digital extensor tendons, used as 4-stranded free tendon grafts, were fixated within porcine femoral bone tunnels by use of extracortical button, cross-pin, or interference screw fixation. One hundred twenty porcine patellar tendon-bone grafts were fixated by use of cross-pin, interference screw, or press-fit fixation. Each femur-graft complex was submitted to cyclic flexion-extension loading for 1,000 cycles throughout different loading ranges, and the total loss of tension was determined. After cyclic testing, the grafts were loaded to failure, and the data were compared with a pullout series without cyclic loading. Tension degradation after 1,000 cycles of flexion-extension loading averaged 62.6% +/- 10.0% in free tendon grafts and 48.9% +/- 13.35% in patellar tendon-bone grafts. There was no influence of the loading range on the total amount of tension degradation. The total amount of tension degradation was the highest with interference screw fixation of free tendon and patellar tendon-bone grafts. Despite excessive loss of tension, the initial fixation strength of the femur-graft complex was not reduced. The method of femoral graft fixation significantly influenced tension degradation during dynamic flexion-extension loading. Femoral graft fixation methods that secure the graft close to the tunnel entrance and that displace the graft substance from the center of the bone tunnel show the largest amount of tension degradation during cyclic flexion-extension loading. The graft substance, not the fixation site, was the weakest link of the graft complex within this investigation. We believe that the graft fixation method should be considered when aiming to improve the precision of femoral graft placement in anterior cruciate ligament reconstruction.
Sedighi, Ali; Sales, Jafar Ganjpour; Alavi, Sahar
2012-11-02
Intertrochanteric fractures (ITFs) are the most common type of fractures requiring surgical intervention. They also have the highest surgical mortality among orthopedic operations. Among the many different techniques used for fixation of this type of fracture, use of the Dynamic Hip Screw (DHS) has gained wide acceptance. This current study was designed to assess positive predictive value of tip-to-apex distance (TAD) index in the prognosis of patients treated with DHS. The study was designed according to a descriptive-analytic protocol, made up of 100 cases of ITFs caused by falling, treated in the Shohada Orthopedic Center, Tabriz, Iran. All patients underwent lateral and antero-posterior hip X-ray to measure TAD index. The cohort was followed for three months after DHS placement. Of a total of 100 cases (53 male, 47 female) with a mean age of 76.7 years (range 29-100 years), 43% had grade 4, 29% grade 3, 21% grade 5, 5% grade 2 and 2% grade 6 osteoporosis. The screw position was postero-inferior in 57%, central in 40% and superior in 3% of patients. Minimum and maximum TAD index were 20 and 28 mm, respectively. Mean TAD was 23.5 mm. There were no post-operative complications in 84% of cases. Screw failure was the most common complication in the remaining 16% of patients. The study shows a statistically significant correlation between TAD index and cut-off rate in patients with intertrochanteric fractures of femoral bone treated by DHS. This validates the use of TAD index in determining the prognosis of patients treated by DHS.
Milenković, Sasa; Mitković, Milorad; Micić, Ivan; Mladenović, Desimir; Najman, Stevo; Trajanović, Miroslav; Manić, Miodrag; Mitković, Milan
2013-09-01
Distal tibial pilon fractures include extra-articular fractures of the tibial metaphysis and the more severe intra-articular tibial pilon fractures. There is no universal method for treating distal tibial pilon fractures. These fractures are treated by means of open reduction, internal fixation (ORIF) and external skeletal fixation. The high rate of soft-tissue complications associated with primary ORIF of pilon fractures led to the use of external skeletal fixation, with limited internal fixation as an alternative technique for definitive management. The aim of this study was to estimate efficacy of distal tibial pilon fratures treatment using the external skeletal and minimal internal fixation method. We presented a series of 31 operated patients with tibial pilon fractures. The patients were operated on using the method of external skeletal fixation with a minimal internal fixation. According to the AO/OTA classification, 17 patients had type B fracture and 14 patients type C fractures. The rigid external skeletal fixation was transformed into a dynamic external skeletal fixation 6 weeks post-surgery. This retrospective study involved 31 patients with tibial pilon fractures, average age 41.81 (from 21 to 60) years. The average follow-up was 21.86 (from 12 to 48) months. The percentage of union was 90.32%, nonunion 3.22% and malunion 6.45%. The mean to fracture union was 14 (range 12-20) weeks. There were 4 (12.19%) infections around the pins of the external skeletal fixator and one (3.22%) deep infections. The ankle joint arthrosis as a late complication appeared in 4 (12.90%) patients. All arthroses appeared in patients who had type C fractures. The final functional results based on the AOFAS score were excellent in 51.61%, good in 32.25%, average in 12.90% and bad in 3.22% of the patients. External skeletal fixation and minimal internal fixation of distal tibial pilon fractures is a good method for treating all types of inta-articular pilon fractures. In fractures types B and C dynamic external skeletal fixation allows early mobility in the ankle joint.
Reoperation following open reduction and plate fixation of displaced mid-shaft clavicle fractures.
Ashman, Bradley D; Slobogean, Gerard P; Stone, Trevor B; Viskontas, Darius G; Moola, Farhad O; Perey, Bertrand H; Boyer, Dory S; McCormack, Robert G
2014-10-01
Operative fixation of displaced, mid-shaft clavicle fractures has become an increasingly common practice. With this emerging trend, data describing patient outcomes with longer follow-up are necessary. We retrospectively reviewed the medical records of subjects treated with plate fixation for displaced mid-shaft clavicle fractures from 2003 to 2009 at a Level I trauma hospital. All subjects were greater than 12 months post-index surgery. Treatment involved ORIF with either a low-contact dynamic compression plate (LCDC) or a contoured plate (pre-contoured or pelvic reconstruction plate). Our primary outcome was reoperation for any indication. 143 subjects were included. The mean age was 36 ± 14 years and the mean time to reoperation or chart review was 33 months. Contoured plates were used in 64% of cases and LCDC plates were used in the remaining subjects. Twenty-nine subjects (20%) underwent reoperation: 23.5% of subjects treated with LCDC plates and 18.5% of subjects treated with contoured plates (p=0.52). Indications for reoperation included implant irritation (n=25), implant failure (n=2), and non-union (n=2). There was near statistically significant association with reoperation and female gender (p=0.05) but no association between reoperation and age (p=0.14), fracture class (p=0.53), plate type (p=0.49), or plate location (p=0.93). The mean QuickDASH score for the population surveyed was 8.8 (5.5-12.1; 95% CI) with near statistically significant and clinically relevant difference between those considering reoperation and those not 22.3 (8.6-36.0; 95% CI) versus 6.7 (3.6-9.8; 95% CI). This study represents a large series of displaced clavicle fractures treated with open reduction and plate fixation. Reoperation following plate fixation is relatively common, but primarily due to implant irritation. No difference in reoperation rates between plate types or location could be detected in our current sample size. Also, excellent functional outcomes continue to be observed several years after clavicle fracture fixation. Copyright © 2014 Elsevier Ltd. All rights reserved.
How Life History Can Sway the Fixation Probability of Mutants
Li, Xiang-Yi; Kurokawa, Shun; Giaimo, Stefano; Traulsen, Arne
2016-01-01
In this work, we study the effects of demographic structure on evolutionary dynamics when selection acts on reproduction, survival, or both. In contrast to the previously discovered pattern that the fixation probability of a neutral mutant decreases while the population becomes younger, we show that a mutant with a constant selective advantage may have a maximum or a minimum of the fixation probability in populations with an intermediate fraction of young individuals. This highlights the importance of life history and demographic structure in studying evolutionary dynamics. We also illustrate the fundamental differences between selection on reproduction and selection on survival when age structure is present. In addition, we evaluate the relative importance of size and structure of the population in determining the fixation probability of the mutant. Our work lays the foundation for also studying density- and frequency-dependent effects in populations when demographic structures cannot be neglected. PMID:27129737
Biometric recognition via fixation density maps
NASA Astrophysics Data System (ADS)
Rigas, Ioannis; Komogortsev, Oleg V.
2014-05-01
This work introduces and evaluates a novel eye movement-driven biometric approach that employs eye fixation density maps for person identification. The proposed feature offers a dynamic representation of the biometric identity, storing rich information regarding the behavioral and physical eye movement characteristics of the individuals. The innate ability of fixation density maps to capture the spatial layout of the eye movements in conjunction with their probabilistic nature makes them a particularly suitable option as an eye movement biometrical trait in cases when free-viewing stimuli is presented. In order to demonstrate the effectiveness of the proposed approach, the method is evaluated on three different datasets containing a wide gamut of stimuli types, such as static images, video and text segments. The obtained results indicate a minimum EER (Equal Error Rate) of 18.3 %, revealing the perspectives on the utilization of fixation density maps as an enhancing biometrical cue during identification scenarios in dynamic visual environments.
Does pediatric body mass index affect surgical outcomes of lower-extremity external fixation?
Fedorak, Graham T; Cuomo, Anna V; Otsuka, Norman Y
2015-06-01
Obese patients are highly prevalent in the pediatric orthopaedic surgeon's practice and obesity is an increasing issue in the United States. Increased body mass index (BMI) has been associated with increased complications in pediatric orthopaedic patients, but no study has looked specifically at external fixation. The purpose of this study was to determine whether obesity is a risk factor for increased complications in lower-extremity procedures requiring external fixation. A retrospective chart review was conducted of pediatric patients who underwent external fixation as definitive operative treatment for any condition at a tertiary care hospital over a 15-year period. Patients were grouped into normal weight, overweight, and obese based on Centers for Disease Control definitions. All orthopaedic complications were recorded. A total of 208 patients with a mean age of 11.2 years were identified. Ninety-four children were obese at the 95th percentile BMI or higher, 22 were overweight and 93 were normal weight. External fixation was applied to the tibia in 82 cases, to the femur in 77 and to both in 49. Mean duration of fixation was 160 days (range, 31 to 570 d) and patients were followed for a mean of 3.9 years (range, 1.0 to 12.0 y). There was no statistically significant difference in the rate of complications between the 3 groups (P=0.61). In the obese group complications occurred in 68.1% versus 66.7% in the overweight group and 61.3% in normal weight. In the setting of external fixator use for lower-extremity pathology in pediatric patients, there is no association between an increase in complications and obesity as defined by BMI. Complication rates are high when external fixation is utilized for the lower extremity, however, patients and families should not be counseled that increased BMI will add to the burden of orthopaedic complications in this situation. Level II-prognostic.
Limb Lengthening and Then Insertion of an Intramedullary Nail: A Case-matched Comparison
Kleinman, Dawn; Fragomen, Austin T.; Ilizarov, Svetlana
2008-01-01
Distraction osteogenesis is an effective method for lengthening, deformity correction, and treatment of nonunions and bone defects. The classic method uses an external fixator for both distraction and consolidation leading to lengthy times in frames and there is a risk of refracture after frame removal. We suggest a new technique: lengthening and then nailing (LATN) technique in which the frame is used for gradual distraction and then a reamed intramedullary nail inserted to support the bone during the consolidation phase, allowing early removal of the external fixator. We performed a retrospective case-matched comparison of patients lengthened with LATN (39 limbs in 27 patients) technique versus the classic (34 limbs in 27 patients). The LATN group wore the external fixator for less time than the classic group (12 versus 29 weeks). The LATN group had a lower external fixation index (0.5 versus 1.9) and a lower bone healing index (0.8 versus 1.9) than the classic group. LATN confers advantages over the classic method including shorter times needed in external fixation, quicker bone healing, and protection against refracture. There are also advantages over the lengthening over a nail and internal lengthening nail techniques. Level of Evidence: Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18800209
Tibial lengthening using a reamed type intramedullary nail and an Ilizarov external fixator
Kim, Hayoung; Kim, Kap Jung; Ahn, Jae Hoon; Choy, Won Sik; Kim, Yong In; Koo, Jea Yun
2008-01-01
The aim of this study was to evaluate the efficacy of tibial lengthening using a reamed type intramedullary nail and an Ilizarov external fixator for the treatment of leg length discrepancy or short stature. This retrospective study was performed on 18 tibiae (13 patients) in which attempts were made to reduce complications. We used an Ilizarov external fixator and a nail (10 mm diameter in 17 tibiae and 11 mm in one tibia) in combination. Average limb lengthening was 4.19 cm (range, 2.5–5.5). The mean duration of external fixation was 12.58 days per centimetre gain in length, and the mean consolidation index was 40.53 (range, 35.45–51.85). All distracted segments healed spontaneously without refracture or malalignment. Gradual limb lengthening using a reamed type intramedullary nail and circular external fixation in combination was found to be reliable and effective and reduced external fixation time with fewer complications. PMID:18415098
Sun, Yapeng; Zhang, Wei; Qie, Suhui; Zhang, Nan; Ding, Wenyuan; Shen, Yong
2017-07-01
The study was to comprehensively compare the postoperative outcome and imaging parameter characters in a short/middle period between the percutaneous endoscopic lumbar discectomy (PELD) and the internal fixation of bone graft fusion (the most common form is posterior lumbar interbody fusion [PLIF]) for the treatment of adjacent segment lumbar disc prolapse with stable retrolisthesis after a previous lumbar internal fixation surgery.In this retrospective case-control study, we collected the medical records from 11 patients who received PELD operation (defined as PELD group) for and from 13 patients who received the internal fixation of bone graft fusion of lumbar posterior vertebral lamina decompression (defined as control group) for the treatment of the lumbar disc prolapse combined with stable retrolisthesis at Department of Spine Surgery, the Third Hospital of Hebei Medical University (Shijiazhuang, China) from May 2010 to December 2015. The operation time, the bleeding volume of perioperation, and the rehabilitation days of postoperation were compared between 2 groups. Before and after surgery at different time points, ODI, VAS index, and imaging parameters (including Taillard index, inter-vertebral height, sagittal dislocation, and forward bending angle of lumbar vertebrae) were compared.The average operation time, the blooding volume, and the rehabilitation days of postoperation were significantly less in PELD than in control group. The ODI and VAS index in PELD group showed a significantly immediate improving on the same day after the surgery. However, Taillard index, intervertebral height, sagittal dislocation in control group showed an immediate improving after surgery, but no changes in PELD group till 12-month after surgery. The forward bending angle of lumbar vertebrae was significantly increased and decreased in PELD and in control group, respectively.PELD operation was superior in terms of operation time, bleeding volume, recovery period, and financial support, if compared with lumbar internal fixation operation. Radiographic parameters reflect lumber structure changes, which could be observed immediately after surgery in both methods; however, the recoveries on nerve function and pain relief required a longer time, especially after PLIF operation.
Johnson, Elizabeth K; Fields, Henry W; Beck, F Michael; Firestone, Allen R; Rosenstiel, Stephen F
2017-02-01
Previous eye-tracking research has demonstrated that laypersons view the range of dental attractiveness levels differently depending on facial attractiveness levels. How the borderline levels of dental attractiveness are viewed has not been evaluated in the context of facial attractiveness and compared with those with near-ideal esthetics or those in definite need of orthodontic treatment according to the Aesthetic Component of the Index of Orthodontic Treatment Need scale. Our objective was to determine the level of viewers' visual attention in its treatment need categories levels 3 to 7 for persons considered "attractive," "average," or "unattractive." Facial images of persons at 3 facial attractiveness levels were combined with 5 levels of dental attractiveness (dentitions representing Aesthetic Component of the Index of Orthodontic Treatment Need levels 3-7) using imaging software to form 15 composite images. Each image was viewed twice by 66 lay participants using eye tracking. Both the fixation density (number of fixations per facial area) and the fixation duration (length of time for each facial area) were quantified for each image viewed. Repeated-measures analysis of variance was used to determine how fixation density and duration varied among the 6 facial interest areas (chin, ear, eye, mouth, nose, and other). Viewers demonstrated excellent to good reliability among the 6 interest areas (intraviewer reliability, 0.70-0.96; interviewer reliability, 0.56-0.93). Between Aesthetic Component of the Index of Orthodontic Treatment Need levels 3 and 7, viewers of all facial attractiveness levels showed an increase in attention to the mouth. However, only with the attractive models were significant differences in fixation density and duration found between borderline levels with female viewers. Female viewers paid attention to different areas of the face than did male viewers. The importance of dental attractiveness is amplified in facially attractive female models compared with average and unattractive female models between near-ideal and borderline-severe dentally unattractive levels. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Fixation probability on clique-based graphs
NASA Astrophysics Data System (ADS)
Choi, Jeong-Ok; Yu, Unjong
2018-02-01
The fixation probability of a mutant in the evolutionary dynamics of Moran process is calculated by the Monte-Carlo method on a few families of clique-based graphs. It is shown that the complete suppression of fixation can be realized with the generalized clique-wheel graph in the limit of small wheel-clique ratio and infinite size. The family of clique-star is an amplifier, and clique-arms graph changes from amplifier to suppressor as the fitness of the mutant increases. We demonstrate that the overall structure of a graph can be more important to determine the fixation probability than the degree or the heat heterogeneity. The dependence of the fixation probability on the position of the first mutant is discussed.
Perception of Object-Context Relations: Eye-Movement Analyses in Infants and Adults
Bornstein, Marc H.; Mash, Clay; Arterberry, Martha E.
2011-01-01
Twenty-eight 4-month-olds’ and 22 20-year-olds’ attention to object-context relations was investigated using a common eye-movement paradigm. Infants and adults scanned both objects and contexts. Infants showed equivalent preferences for animals and vehicles and for congruent and incongruent object-context relations overall, more fixations of objects in congruent object-context relations, more fixations of contexts in incongruent object-context relations, more fixations of objects than contexts in vehicle scenes, and more fixation shifts in incongruent than congruent vehicle scenes. Adults showed more fixations of congruent than incongruent scenes, vehicles than animals, and objects than contexts, equal fixations of animals and their contexts but more fixations of vehicles than their contexts, and more shifts of fixation when inspecting animals in context than vehicles in context. These findings for location, number, and order of eye movements indicate that object-context relations play a dynamic role in the development and allocation of attention. PMID:21244146
Li, Yuewei; Zhang, Minghui; Li, Xiaorong; Chen, Xiaoyong; Deng, Jianlong
2017-07-01
To compare the effectiveness of flexible fixation and rigid fixation in the treatment of ankle pronation-external rotation fractures with distal tibiofibular syndesmosis. A retrospective analysis was made on the clinical data of 50 patients with ankle pronation-external rotation fractures and distal tibiofibular syndesmosis treated between January 2013 and December 2015. Suture-button fixation was used in 23 patients (flexible fixation group) and cortical screw fixation in 27 patients (rigid fixation group). There was no significant difference in age, gender, weight, side, fracture type, and time from trauma to surgery between 2 groups ( P >0.05). The operation time, medial clear space (MCS), tibiofibular clear space (TFCS), tibiofibular overlap (TFO), American Orthopaedic Foot and Ankle Society (AOFAS) score, and Foot and Ankle Disability Index (FADI) score were compared between 2 groups. The operation time was (83.0±9.1) minutes in the flexible fixation group and was (79.6±13.1) minutes in the rigid fixation group, showing no significant difference ( t =1.052, P =0.265). All patients achieved healing of incision by first intention. The patients were followed up 12-20 months (mean, 14 months). The X-ray films showed good healing of fracture in 2 groups. There was no screw fracture, delayed union or nounion. The fracture healing time was (12.1±2.5) months in the flexible fixation group and was (11.3±3.2) months in the rigid fixation group, showing no significant difference between 2 groups ( t =1.024, P =0.192). Reduction loss occurred after removal of screw in 2 cases of the rigid fixation group. At last follow-up, there was no significant difference in MCS, TFCS, TFO, AOFAS score and FADI score between 2 groups ( P >0.05). Suture-button fixation has similar effectiveness to screw fixation in ankle function and imaging findings, and flexible fixation has lower risk of reduction loss of distal tibiofibular syndesmosis than rigid fixation.
Lee, Jeihoon; Lee, Hun; Kang, David Sung Yong; Choi, Jin Young; Kim, Eung Kweon
2016-01-01
Purpose To compare the effectiveness of toric foldable iris-fixated phakic intraocular lens (pIOL) implantation and non-toric foldable iris-fixated pIOL implantation with limbal relaxing incisions (LRIs) for correcting moderate-to-high astigmatism in myopic eyes. Materials and Methods The medical records of 146 patients (195 eyes) with myopic astigmatism who underwent toric foldable iris-fixated pIOL implantation (toric group; 94 eyes) or non-toric foldable iris-fixated pIOL implantation with concurrent LRIs (LRI group; 101 eyes) were retrospectively reviewed. For subgroup analysis, the two groups were subdivided according to preoperative astigmatic severity [moderate, 2.00 to <3.00 diopters (D); high, 3.00–4.00 D]. Visual and astigmatic outcomes were compared 6 months postoperatively. Results The uncorrected distance visual acuity was at least 20/25 in 100% and 98% of the toric and LRI group eyes, respectively. The toric group had lower mean residual cylindrical error (-0.67±0.39 D vs. -1.14±0.56 D; p<0.001) and greater mean cylindrical error change (2.17±0.56 D vs. 1.63±0.72 D; p<0.001) than the LRI group, regardless of the preoperative astigmatic severity. The mean correction index (1.10±0.16 vs. 0.72±0.24; p<0.001) and success index (0.24±0.14 vs. 0.42±0.21; p<0.001) also differed significantly between the groups. Conclusion Both surgical techniques considerably reduced astigmatism and had comparable visual outcomes. However, toric foldable iris-fixated pIOL implantation was more reliable for correcting moderate-to-high astigmatism in myopic eyes. PMID:27593877
Lee, Jeihoon; Lee, Hun; Kang, David Sung Yong; Choi, Jin Young; Kim, Eung Kweon; Kim, Tae Im
2016-11-01
To compare the effectiveness of toric foldable iris-fixated phakic intraocular lens (pIOL) implantation and non-toric foldable iris-fixated pIOL implantation with limbal relaxing incisions (LRIs) for correcting moderate-to-high astigmatism in myopic eyes. The medical records of 146 patients (195 eyes) with myopic astigmatism who underwent toric foldable iris-fixated pIOL implantation (toric group; 94 eyes) or non-toric foldable iris-fixated pIOL implantation with concurrent LRIs (LRI group; 101 eyes) were retrospectively reviewed. For subgroup analysis, the two groups were subdivided according to preoperative astigmatic severity [moderate, 2.00 to <3.00 diopters (D); high, 3.00-4.00 D]. Visual and astigmatic outcomes were compared 6 months postoperatively. The uncorrected distance visual acuity was at least 20/25 in 100% and 98% of the toric and LRI group eyes, respectively. The toric group had lower mean residual cylindrical error (-0.67±0.39 D vs. -1.14±0.56 D; p<0.001) and greater mean cylindrical error change (2.17±0.56 D vs. 1.63±0.72 D; p<0.001) than the LRI group, regardless of the preoperative astigmatic severity. The mean correction index (1.10±0.16 vs. 0.72±0.24; p<0.001) and success index (0.24±0.14 vs. 0.42±0.21; p<0.001) also differed significantly between the groups. Both surgical techniques considerably reduced astigmatism and had comparable visual outcomes. However, toric foldable iris-fixated pIOL implantation was more reliable for correcting moderate-to-high astigmatism in myopic eyes.
High-performance object tracking and fixation with an online neural estimator.
Kumarawadu, Sisil; Watanabe, Keigo; Lee, Tsu-Tian
2007-02-01
Vision-based target tracking and fixation to keep objects that move in three dimensions in view is important for many tasks in several fields including intelligent transportation systems and robotics. Much of the visual control literature has focused on the kinematics of visual control and ignored a number of significant dynamic control issues that limit performance. In line with this, this paper presents a neural network (NN)-based binocular tracking scheme for high-performance target tracking and fixation with minimum sensory information. The procedure allows the designer to take into account the physical (Lagrangian dynamics) properties of the vision system in the control law. The design objective is to synthesize a binocular tracking controller that explicitly takes the systems dynamics into account, yet needs no knowledge of dynamic nonlinearities and joint velocity sensory information. The combined neurocontroller-observer scheme can guarantee the uniform ultimate bounds of the tracking, observer, and NN weight estimation errors under fairly general conditions on the controller-observer gains. The controller is tested and verified via simulation tests in the presence of severe target motion changes.
The time course of saccadic decision making: dynamic field theory.
Wilimzig, Claudia; Schneider, Stefan; Schöner, Gregor
2006-10-01
Making a saccadic eye movement involves two decisions, the decision to initiate the saccade and the selection of the visual target of the saccade. Here we provide a theoretical account for the time-courses of these two processes, whose instabilities are the basis of decision making. We show how the cross-over from spatial averaging for fast saccades to selection for slow saccades arises from the balance between excitatory and inhibitory processes. Initiating a saccade involves overcoming fixation, as can be observed in the countermanding paradigm, which we model accounting both for the temporal evolution of the suppression probability and its dependence on fixation activity. The interaction between the two forms of decision making is demonstrated by predicting how the cross-over from averaging to selection depends on the fixation stimulus in gap-step-overlap paradigms. We discuss how the activation dynamics of our model may be mapped onto neuronal structures including the motor map and the fixation cells in superior colliculus.
Fast and asymptotic computation of the fixation probability for Moran processes on graphs.
Alcalde Cuesta, F; González Sequeiros, P; Lozano Rojo, Á
2015-03-01
Evolutionary dynamics has been classically studied for homogeneous populations, but now there is a growing interest in the non-homogeneous case. One of the most important models has been proposed in Lieberman et al. (2005), adapting to a weighted directed graph the process described in Moran (1958). The Markov chain associated with the graph can be modified by erasing all non-trivial loops in its state space, obtaining the so-called Embedded Markov chain (EMC). The fixation probability remains unchanged, but the expected time to absorption (fixation or extinction) is reduced. In this paper, we shall use this idea to compute asymptotically the average fixation probability for complete bipartite graphs K(n,m). To this end, we firstly review some recent results on evolutionary dynamics on graphs trying to clarify some points. We also revisit the 'Star Theorem' proved in Lieberman et al. (2005) for the star graphs K(1,m). Theoretically, EMC techniques allow fast computation of the fixation probability, but in practice this is not always true. Thus, in the last part of the paper, we compare this algorithm with the standard Monte Carlo method for some kind of complex networks. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
The dynamic volume changes of polymerising polymethyl methacrylate bone cement.
Muller, Scott D; Green, Sarah M; McCaskie, Andrew W
2002-12-01
The Swedish hip register found an increased risk of early revision of vacuum-mixed cemented total hip replacements. The influence of cement mixing technique on the dynamic volume change in polymerising PMMA is not well understood and may be relevant to this observation. Applying Archimedes' principle, we have investigated the dynamic volume changes in polymerising cement and determined the influence of mixing technique. All specimens showed an overall volume reduction: hand-mixed 3.4% and vacuum-mixed 6.0%. Regression analysis of sectional porosity and volume reduction showed a highly significant relationship. Hand-mixed porous cement showed a transient volume increase before solidification. However, vacuum-mixed cement showed a progressive volume reduction throughout polymerisation. Transient expansion of porous cement occurs at the critical time of micro-interlock formation, possibly improving fixation. Conversely, progressive volume reduction of vacuum-mixed cement throughout the formation of interlock may damage fixation. Stable fixation of vacuum-mixed cement may depend on additional techniques to offset the altered volumetric behaviour of vacuum-mixed cement.
Fixation of strategies with the Moran and Fermi processes in evolutionary games
NASA Astrophysics Data System (ADS)
Liu, Xuesong; He, Mingfeng; Kang, Yibin; Pan, Qiuhui
2017-10-01
A model of stochastic evolutionary game dynamics with finite population was built. It combines the standard Moran and Fermi rules with two strategies cooperation and defection. We obtain the expressions of fixation probabilities and fixation times. The one-third rule which has been found in the frequency dependent Moran process also holds for our model. We obtain the conditions of strategy being an evolutionarily stable strategy in our model, and then make a comparison with the standard Moran process. Besides, the analytical results show that compared with the standard Moran process, fixation occurs with higher probabilities under a prisoner's dilemma game and coordination game, but with lower probabilities under a coexistence game. The simulation result shows that the fixation time in our mixed process is lower than that in the standard Fermi process. In comparison with the standard Moran process, fixation always takes more time on average in spatial populations, regardless of the game. In addition, the fixation time decreases with the growth of the number of neighbors.
Biomechanical Concepts for Fracture Fixation
Bottlang, Michael; Schemitsch, Christine E.; Nauth, Aaron; Routt, Milton; Egol, Kenneth; Cook, Gillian E.; Schemitsch, Emil H.
2015-01-01
Application of the correct fixation construct is critical for fracture healing and long-term stability; however, it is a complex issue with numerous significant factors. This review describes a number of common fracture types, and evaluates their currently available fracture fixation constructs. In the setting of complex elbow instability, stable fixation or radial head replacement with an appropriately sized implant in conjunction with ligamentous repair is required to restore stability. For unstable sacral fractures, “standard” iliosacral screw fixation is not sufficient for fractures with vertical or multiplanar instabilities. Periprosthetic femur fractures, in particular Vancouver B1 fractures, have increased stability when using 90/90 fixation versus a single locking plate. Far Cortical Locking combines the concept of dynamization with locked plating in order to achieve superior healing of a distal femur fracture. Finally, there is no ideal construct for syndesmotic fracture stabilization; however, these fractures should be fixed using a device that allows for sufficient motion in the syndesmosis. In general, orthopaedic surgeons should select a fracture fixation construct that restores stability and promotes healing at the fracture site, while reducing the potential for fixation failure. PMID:26584263
Sogbedji, Jean M; McIsaac, Gregory F
2006-01-01
Assessing the accuracy of agronomic and water quality simulation models in different soils, land-use systems, and environments provides a basis for using and improving these models. We evaluated the performance of the ADAPT model for simulating riverine nitrate-nitrogen (NO3-N) export from a 1500-km2 watershed in central Illinois, where approximately 85% of the land is used for maize-soybean production and tile drainage is common. Soil chemical properties, crop nitrogen (N) uptake coefficient, dry matter ratio, and a denitrification reduction coefficient were used as calibration parameters to optimize the fit between measured and simulated NO3-N load from the watershed for the 1989 to 1993 period. The applicability of the calibrated parameter values was tested by using these values for simulating the 1994 to 1997 period on the same watershed. Willmott's index of agreement ranged from 0.91 to 0.97 for daily, weekly, monthly, and annual comparisons of riverine nitrate N loads. Simulation accuracy generally decreased as the time interval decreased. Willmott's index for simulated crop yields ranged from 0.91 to 0.99; however, observed crop yields were used as input to the model. The partial N budget results suggested that 52 to 72 kg N ha(-1) yr(-1) accumulated in the soil, but simulated biological N fixation associated with soybeans was considerably greater than literature values for the region. Improvement of the N fixation algorithms and incorporation of mechanisms that describe soybean yield in response to environmental conditions appear to be needed to improve the performance of the model.
2014-10-01
initiated. One such fixator has been tested on a cadaveric sheep tibia. In the unlocked, loose position, the axial stiffness of the tibia and fixator...suggested by our previous studies using rats. This aspect of the project is the present focus of attention, and additional cadaver legs will be tested...characterize external fixators). A 3 mm tibial defect was created in the leg of a cadaveric sheep, and stabilized with an experimental external
Fixation free femoral hernia repair with a 3D dynamic responsive implant. A case series report.
Amato, G; Romano, G; Agrusa, A; Gordini, L; Gulotta, E; Erdas, E; Calò, P G
2018-04-23
To date, no gold standard for the surgical treatment of femoral hernia exists. Pure tissue repair as well as mesh/plug implantation, open or laparoscopic, are the most performed methods. Nevertheless, all these techniques need sutures or mesh fixation. This implies the risk of damaging sensitive structures of the femoral area, along with complications related to tissue tear and postoperative discomfort consequent to poor quality mesh incorporation. The present retrospective multicenter case series highlights the results of femoral hernia repair procedures performed with a 3D dynamic responsive implant in a cohort of 32 patients during a mean follow up of 27 months. Aiming to simplify the surgical procedure and reduce complications, a 3D dynamic responsive implant was delivered for femoral hernia repair, in a patient cohort. After returning the hernia sack to the abdominal cavity, the implant was simply delivered into the hernia defect where it remained, thanks to its inherent centrifugal expansion, obliterating the hernia opening without need of fixation. Postoperative pain assessment was determined using the VAS score system. The use of the 3D prosthetic device allowed for easier and faster surgical repair in a fixation free fashion. None of the typical fixation related complications occurred in the examined patients. Postoperative pain assessment with VAS score showed a very low level of pain, allowing the return of patients to normal activities in extremely reduced times. In the late postoperative period, no discomfort or chronic pain was reported. Femoral hernia repair with the 3D dynamic revealed a quick and safe placement procedure. The reduced pain intensity, as well as the absence of adverse events consequent to sutures or mesh fixation, seems to be a significant benefit of the motile compliance of the device. Furthermore, this 3D prosthesis has already proven to induce an enhanced probiotic response showing ingrowth in the implant of the typical tissue components of the abdominal wall, instead of the low quality tissue ingrowth typical in conventional meshes and plugs. The highlighted features seem to represent a more physiologic and updated repair concept of femoral protrusions. Copyright © 2018 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
Arizpe, Joseph; Kravitz, Dwight J.; Yovel, Galit; Baker, Chris I.
2012-01-01
Fixation patterns are thought to reflect cognitive processing and, thus, index the most informative stimulus features for task performance. During face recognition, initial fixations to the center of the nose have been taken to indicate this location is optimal for information extraction. However, the use of fixations as a marker for information use rests on the assumption that fixation patterns are predominantly determined by stimulus and task, despite the fact that fixations are also influenced by visuo-motor factors. Here, we tested the effect of starting position on fixation patterns during a face recognition task with upright and inverted faces. While we observed differences in fixations between upright and inverted faces, likely reflecting differences in cognitive processing, there was also a strong effect of start position. Over the first five saccades, fixation patterns across start positions were only coarsely similar, with most fixations around the eyes. Importantly, however, the precise fixation pattern was highly dependent on start position with a strong tendency toward facial features furthest from the start position. For example, the often-reported tendency toward the left over right eye was reversed for the left starting position. Further, delayed initial saccades for central versus peripheral start positions suggest greater information processing prior to the initial saccade, highlighting the experimental bias introduced by the commonly used center start position. Finally, the precise effect of face inversion on fixation patterns was also dependent on start position. These results demonstrate the importance of a non-stimulus, non-task factor in determining fixation patterns. The patterns observed likely reflect a complex combination of visuo-motor effects and simple sampling strategies as well as cognitive factors. These different factors are very difficult to tease apart and therefore great caution must be applied when interpreting absolute fixation locations as indicative of information use, particularly at a fine spatial scale. PMID:22319606
Noh, Jung Ho; Roh, Young Hak; Yang, Bo Gyu; Kim, Seong Wan; Lee, Jun Suk; Oh, Moo Kyung
2012-11-21
Biodegradable implants for internal fixation of ankle fractures may overcome some disadvantages of metallic implants, such as imaging interference and the potential need for additional surgery to remove the implants. The purpose of this study was to evaluate the outcomes after fixation of ankle fractures with biodegradable implants compared with metallic implants. In this prospectively randomized study, 109 subjects with an ankle fracture underwent surgery with metallic (Group I) or biodegradable implants (Group II). Radiographic results were assessed by the criteria of the Klossner classification system and time to bone union. Clinical results were assessed with use of the American Orthopaedic Foot & Ankle Society (AOFAS) ankle-hindfoot scale, Short Musculoskeletal Function Assessment (SMFA) dysfunction index, and the SMFA bother index at three, six, and twelve months after surgery. One hundred and two subjects completed the study. At a mean of 19.7 months, there were no differences in reduction quality between the groups. The mean operative time was 30.2 minutes in Group I and 56.4 minutes in Group II (p < 0.001). The mean time to bone union was 15.8 weeks in Group I and 17.6 weeks in Group II (p = 0.002). The mean AOFAS score was 87.5 points in Group I and 84.3 points in Group II at twelve months after surgery (p = 0.004). The mean SMFA dysfunction index was 8.7 points in Group I and 10.5 points in Group II at twelve months after surgery (p = 0.060). The mean SMFA bother index averaged 3.3 points in Group I and 4.6 points in Group II at twelve months after surgery (p = 0.052). No difference existed between the groups with regard to clinical outcomes for the subjects with an isolated lateral malleolar fracture. The outcomes after fixation of bimalleolar ankle fractures with biodegradable implants were inferior to those after fixation with metallic implants in terms of the score on the AOFAS scale and time to bone union. However, the difference in the final AOFAS score between the groups may not be clinically important. The outcomes associated with the use of biodegradable implants for the fixation of isolated lateral malleolar fractures were comparable with those for metallic implants.
The Narrative Labyrinth of Violent Dying
ERIC Educational Resources Information Center
Rynearson, E. K.
2005-01-01
This essay outlines the dynamics of retelling the violent death of a loved one and the narrative "dilemma" of vulnerable family members fixated on retelling. To counter this fixation, the author presents a mythic retelling of violent death (the Myth of Theseus) as narrative basis for developing a restorative retelling. The essay begins by…
Fixation and Commitment while Designing and Its Measurement
ERIC Educational Resources Information Center
Gero, John S.
2011-01-01
This paper introduces the notion that fixation and commitment while designing can be measured by studying the protocol of the design session. It is hypothesized that the dynamic entropy of the linkograph of the protocol provides the basis for such a measurement. The hypothesis is empirically tested using a design protocol and the results…
Matsumoto, Yukiko; Takahashi, Hideyuki; Murai, Toshiya; Takahashi, Hidehiko
2015-01-01
Schizophrenia patients have impairments at several levels of cognition including visual attention (eye movements), perception, and social cognition. However, it remains unclear how lower-level cognitive deficits influence higher-level cognition. To elucidate the hierarchical path linking deficient cognitions, we focused on biological motion perception, which is involved in both the early stage of visual perception (attention) and higher social cognition, and is impaired in schizophrenia. Seventeen schizophrenia patients and 18 healthy controls participated in the study. Using point-light walker stimuli, we examined eye movements during biological motion perception in schizophrenia. We assessed relationships among eye movements, biological motion perception and empathy. In the biological motion detection task, schizophrenia patients showed lower accuracy and fixated longer than healthy controls. As opposed to controls, patients exhibiting longer fixation durations and fewer numbers of fixations demonstrated higher accuracy. Additionally, in the patient group, the correlations between accuracy and affective empathy index and between eye movement index and affective empathy index were significant. The altered gaze patterns in patients indicate that top-down attention compensates for impaired bottom-up attention. Furthermore, aberrant eye movements might lead to deficits in biological motion perception and finally link to social cognitive impairments. The current findings merit further investigation for understanding the mechanism of social cognitive training and its development. Copyright © 2014 Elsevier Ireland Ltd and the Japan Neuroscience Society. All rights reserved.
Berney, Christophe R; Descallar, Joseph
2016-10-01
Chronic pain is a common complication arising after conventional open herniorrhaphy and to a lesser extent postlaparoscopic inguinal hernia repairs as groin incision is avoided. Although published studies support elimination of mesh fixation during endoscopic procedures, the vast majority of surgeons will still recommend it by fear of encountering increased recurrence rates, if omitted. Regrettably, penetrating staple or tack fixation devices are the preferred methods to secure the mesh and cannot be applied at the level of the triangles of 'doom' and 'pain' where hernia tends to reoccur the most. This ongoing prospective cohort study aimed to confirm the safety and advantages of fibrin glue, as a substitute to staple mesh fixation during totally extraperitoneal (TEP) inguinal hernia repair. Over a 10-year period, 703 patients underwent 1000 elective TEP inguinal hernia repairs. Mesh fixation was achieved using exclusively fibrin sealant. Patients were reviewed at 2, 6 weeks and thereafter on an ad hoc basis if judged necessary until complete resolution of their symptoms. Quality of life (QoL) was assessed in a subgroup of 320 patients using the Carolina Comfort Scale (CCS). No conversion to open surgery was observed. There were three cases of major morbidities and no mortality. Three months after surgery, only seven patients (1 %) experienced chronic groin or testicular discomfort and none of them required prescription painkillers. When using the CCS, at 2 weeks 93.1 % of the patients were either satisfied or very satisfied with their outcome. This satisfaction index increased up to 99.2 % at 6 weeks post surgery. Finally, only eight hernia recurrences (1.1 %) were reported, of which five occurred during the first month of the study. Fibrin glue mesh fixation of inguinal hernia during TEP repair is extremely safe and reliable, with a very high satisfaction index for the patients and limited risk of developing chronic pain.
Fixation Probability in a Haploid-Diploid Population
Bessho, Kazuhiro; Otto, Sarah P.
2017-01-01
Classical population genetic theory generally assumes either a fully haploid or fully diploid life cycle. However, many organisms exhibit more complex life cycles, with both free-living haploid and diploid stages. Here we ask what the probability of fixation is for selected alleles in organisms with haploid-diploid life cycles. We develop a genetic model that considers the population dynamics using both the Moran model and Wright–Fisher model. Applying a branching process approximation, we obtain an accurate fixation probability assuming that the population is large and the net effect of the mutation is beneficial. We also find the diffusion approximation for the fixation probability, which is accurate even in small populations and for deleterious alleles, as long as selection is weak. These fixation probabilities from branching process and diffusion approximations are similar when selection is weak for beneficial mutations that are not fully recessive. In many cases, particularly when one phase predominates, the fixation probability differs substantially for haploid-diploid organisms compared to either fully haploid or diploid species. PMID:27866168
Evolutionary dynamics with fluctuating population sizes and strong mutualism.
Chotibut, Thiparat; Nelson, David R
2015-08-01
Game theory ideas provide a useful framework for studying evolutionary dynamics in a well-mixed environment. This approach, however, typically enforces a strictly fixed overall population size, deemphasizing natural growth processes. We study a competitive Lotka-Volterra model, with number fluctuations, that accounts for natural population growth and encompasses interaction scenarios typical of evolutionary games. We show that, in an appropriate limit, the model describes standard evolutionary games with both genetic drift and overall population size fluctuations. However, there are also regimes where a varying population size can strongly influence the evolutionary dynamics. We focus on the strong mutualism scenario and demonstrate that standard evolutionary game theory fails to describe our simulation results. We then analytically and numerically determine fixation probabilities as well as mean fixation times using matched asymptotic expansions, taking into account the population size degree of freedom. These results elucidate the interplay between population dynamics and evolutionary dynamics in well-mixed systems.
Evolutionary dynamics with fluctuating population sizes and strong mutualism
NASA Astrophysics Data System (ADS)
Chotibut, Thiparat; Nelson, David R.
2015-08-01
Game theory ideas provide a useful framework for studying evolutionary dynamics in a well-mixed environment. This approach, however, typically enforces a strictly fixed overall population size, deemphasizing natural growth processes. We study a competitive Lotka-Volterra model, with number fluctuations, that accounts for natural population growth and encompasses interaction scenarios typical of evolutionary games. We show that, in an appropriate limit, the model describes standard evolutionary games with both genetic drift and overall population size fluctuations. However, there are also regimes where a varying population size can strongly influence the evolutionary dynamics. We focus on the strong mutualism scenario and demonstrate that standard evolutionary game theory fails to describe our simulation results. We then analytically and numerically determine fixation probabilities as well as mean fixation times using matched asymptotic expansions, taking into account the population size degree of freedom. These results elucidate the interplay between population dynamics and evolutionary dynamics in well-mixed systems.
Molybdenum and Phosphorus Interact to Constrain Asymbiotic Nitrogen Fixation in Tropical Forests
Wurzburger, Nina; Bellenger, Jean Philippe; Kraepiel, Anne M. L.; Hedin, Lars O.
2012-01-01
Biological di-nitrogen fixation (N2) is the dominant natural source of new nitrogen to land ecosystems. Phosphorus (P) is thought to limit N2 fixation in many tropical soils, yet both molybdenum (Mo) and P are crucial for the nitrogenase reaction (which catalyzes N2 conversion to ammonia) and cell growth. We have limited understanding of how and when fixation is constrained by these nutrients in nature. Here we show in tropical forests of lowland Panama that the limiting element on asymbiotic N2 fixation shifts along a broad landscape gradient in soil P, where Mo limits fixation in P-rich soils while Mo and P co-limit in P-poor soils. In no circumstance did P alone limit fixation. We provide and experimentally test a mechanism that explains how Mo and P can interact to constrain asymbiotic N2 fixation. Fixation is uniformly favored in surface organic soil horizons - a niche characterized by exceedingly low levels of available Mo relative to P. We show that soil organic matter acts to reduce molybdate over phosphate bioavailability, which, in turn, promotes Mo limitation in sites where P is sufficient. Our findings show that asymbiotic N2 fixation is constrained by the relative availability and dynamics of Mo and P in soils. This conceptual framework can explain shifts in limitation status across broad landscape gradients in soil fertility and implies that fixation depends on Mo and P in ways that are more complex than previously thought. PMID:22470462
NASA Astrophysics Data System (ADS)
Trierweiler, A.; Xu, X.; Gei, M. G.; Powers, J. S.; Medvigy, D.
2016-12-01
Tropical dry forests (TDFs) have immense functional diversity and face multiple resource constraints (both water and nutrients). Legumes are abundant and exhibit a wide diversity of N2-fixing strategies in TDFs. The abundance and diversity of legumes and their interaction with N2-fixing bacteria may strongly control the coupled carbon-nitrogen cycle in the biome and influence whether TDFs will be particularly vulnerable or uniquely adapted to projected global change. However, the importance of N2-fixation in TDFs and the carbon cost of acquiring N through symbiotic relationships are not fully understood. Here, we use models along with field measurements to examine the role of legumes, nitrogen fixation, and plant-symbiont nutrient exchanges in TDFs. We use a new version of the Ecosystem Demography (ED2) model that has been recently parameterized for TDFs. The new version incorporates plant-mycorrhizae interactions and multiple resource constraints (carbon, nitrogen, phosphorus, and water). We represent legumes and other functional groups found in TDFs with a range of resource acquisition strategies. In the model, plants then can dynamically adjust their carbon allocation and nutrient acquisition strategies (e.g. N2-fixing bacteria and mycorrhizal fungi) according to the nutrient limitation status. We test (i) the model's performance against a nutrient gradient of field sites in Costa Rica and (ii) the model's sensitivity to the carbon cost to acquire N through fixation and mycorrhizal relationships. We also report on simulated tree community responses to ongoing field nutrient fertilization experiments. We found that the inclusion of the N2-fixation legume plant functional traits were critical to reproducing community dynamics of Costa Rican field TDF sites and have a large impact on forest biomass. Simulated ecosystem fixation rates matched the magnitude and temporal patterns of field measured fixation. Our results show that symbiotic nitrogen fixation plays an important role in tropical dry forests and biomass accumulation. Also, we suggest that fixation's tight link to the rainy season could result in potential nutrient cycling vulnerabilities with projected rainfall changes.
Docker, Charles; Starks, Ian; Wade, Roger; Wynn-Jones, Charles
2011-06-01
We present the case of a woman diagnosed with simultaneous displaced intracapsular femoral neck fractures following the birth of her second child. No traumatic event was identified. Diagnosis was delayed as the cause of her pain was thought to be non-skeletal in origin. Radiological and serological investigations were diagnostic of osteomalacia. Surgical fixation of her fractures was further delayed due to profound hypocalcaemia. Despite the delays, fixation with bilateral dynamic hip screws resulted in union with no evidence of avascular necrosis at 2 years follow-up. We believe this to be the first report of atraumatic bilateral femoral neck fractures and it shows that a good result can be achieved even in the presence of delayed fixation.
Non-fixation for Conservative Stochastic Dynamics on the Line
NASA Astrophysics Data System (ADS)
Basu, Riddhipratim; Ganguly, Shirshendu; Hoffman, Christopher
2018-03-01
We consider activated random walk (ARW), a model which generalizes the stochastic sandpile, one of the canonical examples of self organized criticality. Informally ARW is a particle system on Z with mass conservation. One starts with a mass density {μ > 0} of initially active particles, each of which performs a symmetric random walk at rate one and falls asleep at rate {λ > 0}. Sleepy particles become active on coming in contact with other active particles. We investigate the question of fixation/non-fixation of the process and show for small enough {λ} the critical mass density for fixation is strictly less than one. Moreover, the critical density goes to zero as {λ} tends to zero. This settles a long standing open question.
The narrative labyrinth of violent dying.
Rynearson, E K
2005-05-01
This essay outlines the dynamics of retelling the violent death of a loved one and the narrative "dilemma" of vulnerable family members fixated on retelling. To counter this fixation, the author presents a mythic retelling of violent death (the Myth of Theseus) as narrative basis for developing a restorative retelling. The essay begins by exploring the deformed and deforming structure of the violent dying story, then details the dynamics of its retelling and concludes by presenting a restorative retelling model for family members who cannot release themselves from the story for months or years after the violent dying.
Molecular Clock of Neutral Mutations in a Fitness-Increasing Evolutionary Process
Iijima, Leo; Suzuki, Shingo; Hashimoto, Tomomi; Oyake, Ayana; Kobayashi, Hisaka; Someya, Yuki; Narisawa, Dai; Yomo, Tetsuya
2015-01-01
The molecular clock of neutral mutations, which represents linear mutation fixation over generations, is theoretically explained by genetic drift in fitness-steady evolution or hitchhiking in adaptive evolution. The present study is the first experimental demonstration for the molecular clock of neutral mutations in a fitness-increasing evolutionary process. The dynamics of genome mutation fixation in the thermal adaptive evolution of Escherichia coli were evaluated in a prolonged evolution experiment in duplicated lineages. The cells from the continuously fitness-increasing evolutionary process were subjected to genome sequencing and analyzed at both the population and single-colony levels. Although the dynamics of genome mutation fixation were complicated by the combination of the stochastic appearance of adaptive mutations and clonal interference, the mutation fixation in the population was simply linear over generations. Each genome in the population accumulated 1.6 synonymous and 3.1 non-synonymous neutral mutations, on average, by the spontaneous mutation accumulation rate, while only a single genome in the population occasionally acquired an adaptive mutation. The neutral mutations that preexisted on the single genome hitchhiked on the domination of the adaptive mutation. The successive fixation processes of the 128 mutations demonstrated that hitchhiking and not genetic drift were responsible for the coincidence of the spontaneous mutation accumulation rate in the genome with the fixation rate of neutral mutations in the population. The molecular clock of neutral mutations to the fitness-increasing evolution suggests that the numerous neutral mutations observed in molecular phylogenetic trees may not always have been fixed in fitness-steady evolution but in adaptive evolution. PMID:26177190
Molecular Clock of Neutral Mutations in a Fitness-Increasing Evolutionary Process.
Kishimoto, Toshihiko; Ying, Bei-Wen; Tsuru, Saburo; Iijima, Leo; Suzuki, Shingo; Hashimoto, Tomomi; Oyake, Ayana; Kobayashi, Hisaka; Someya, Yuki; Narisawa, Dai; Yomo, Tetsuya
2015-07-01
The molecular clock of neutral mutations, which represents linear mutation fixation over generations, is theoretically explained by genetic drift in fitness-steady evolution or hitchhiking in adaptive evolution. The present study is the first experimental demonstration for the molecular clock of neutral mutations in a fitness-increasing evolutionary process. The dynamics of genome mutation fixation in the thermal adaptive evolution of Escherichia coli were evaluated in a prolonged evolution experiment in duplicated lineages. The cells from the continuously fitness-increasing evolutionary process were subjected to genome sequencing and analyzed at both the population and single-colony levels. Although the dynamics of genome mutation fixation were complicated by the combination of the stochastic appearance of adaptive mutations and clonal interference, the mutation fixation in the population was simply linear over generations. Each genome in the population accumulated 1.6 synonymous and 3.1 non-synonymous neutral mutations, on average, by the spontaneous mutation accumulation rate, while only a single genome in the population occasionally acquired an adaptive mutation. The neutral mutations that preexisted on the single genome hitchhiked on the domination of the adaptive mutation. The successive fixation processes of the 128 mutations demonstrated that hitchhiking and not genetic drift were responsible for the coincidence of the spontaneous mutation accumulation rate in the genome with the fixation rate of neutral mutations in the population. The molecular clock of neutral mutations to the fitness-increasing evolution suggests that the numerous neutral mutations observed in molecular phylogenetic trees may not always have been fixed in fitness-steady evolution but in adaptive evolution.
The evolution of small insertions and deletions in the coding genes of Drosophila melanogaster.
Chong, Zechen; Zhai, Weiwei; Li, Chunyan; Gao, Min; Gong, Qiang; Ruan, Jue; Li, Juan; Jiang, Lan; Lv, Xuemei; Hungate, Eric; Wu, Chung-I
2013-12-01
Studies of protein evolution have focused on amino acid substitutions with much less systematic analysis on insertion and deletions (indels) in protein coding genes. We hence surveyed 7,500 genes between Drosophila melanogaster and D. simulans, using D. yakuba as an outgroup for this purpose. The evolutionary rate of coding indels is indeed low, at only 3% of that of nonsynonymous substitutions. As coding indels follow a geometric distribution in size and tend to fall in low-complexity regions of proteins, it is unclear whether selection or mutation underlies this low rate. To resolve the issue, we collected genomic sequences from an isogenic African line of D. melanogaster (ZS30) at a high coverage of 70× and analyzed indel polymorphism between ZS30 and the reference genome. In comparing polymorphism and divergence, we found that the divergence to polymorphism ratio (i.e., fixation index) for smaller indels (size ≤ 10 bp) is very similar to that for synonymous changes, suggesting that most of the within-species polymorphism and between-species divergence for indels are selectively neutral. Interestingly, deletions of larger sizes (size ≥ 11 bp and ≤ 30 bp) have a much higher fixation index than synonymous mutations and 44.4% of fixed middle-sized deletions are estimated to be adaptive. To our surprise, this pattern is not found for insertions. Protein indel evolution appear to be in a dynamic flux of neutrally driven expansion (insertions) together with adaptive-driven contraction (deletions), and these observations provide important insights for understanding the fitness of new mutations as well as the evolutionary driving forces for genomic evolution in Drosophila species.
Dickinson, Christopher A.; Zelinsky, Gregory J.
2013-01-01
Two experiments are reported that further explore the processes underlying dynamic search. In Experiment 1, observers’ oculomotor behavior was monitored while they searched for a randomly oriented T among oriented L distractors under static and dynamic viewing conditions. Despite similar search slopes, eye movements were less frequent and more spatially constrained under dynamic viewing relative to static, with misses also increasing more with target eccentricity in the dynamic condition. These patterns suggest that dynamic search involves a form of sit-and-wait strategy in which search is restricted to a small group of items surrounding fixation. To evaluate this interpretation, we developed a computational model of a sit-and-wait process hypothesized to underlie dynamic search. In Experiment 2 we tested this model by varying fixation position in the display and found that display positions optimized for a sit-and-wait strategy resulted in higher d′ values relative to a less optimal location. We conclude that different strategies, and therefore underlying processes, are used to search static and dynamic displays. PMID:23372555
Mulenge, Felix M.; Hunja, Carol W.; Magiri, Esther; Culleton, Richard; Kaneko, Akira; Aman, Rashid A.
2016-01-01
Understanding the genetic structure and transmission dynamics of Plasmodium falciparum parasites in malaria-endemic regions is crucial before the implementation of interventions. Located in a high-transmission region of western Kenya where P. falciparum is the predominant species, the Lake Victoria islands are ideal for feasibility of malaria elimination studies. We analyzed genetic variation in eight microsatellite loci to examine parasite population structure and gene flow patterns across five sites. High levels of genetic diversity were measured throughout the region (mean heterozygosity index = 0.84). The overall fixation index value between the sites was 0.044, indicating that approximately 5% of the overall allelic variation is due to differences between the populations. Based on these results, we concluded that parasite population structure in the studied islands is shaped by human migration patterns that maintain extensive parasite gene flow between the sites. Consequently, any malaria elimination and interventions strategies in the study area will have to be carried out broadly on all four islands and adjoining mainland region. PMID:27601522
Shih, Kao-Shang; Truong, Thanh An; Hsu, Ching-Chi; Hou, Sheng-Mou
2017-11-02
Rib fracture is a common injury and can result in pain during respiration. Conservative treatment of rib fracture is applied via mechanical ventilation. However, ventilator-associated complications frequently occur. Surgical fixation is another approach to treat rib fractures. Unfortunately, this surgical treatment is still not completely defined. Past studies have evaluated the biomechanics of the rib cage during respiration using a finite element method, but only intact conditions were modelled. Thus, the purpose of this study was to develop a realistic numerical model of the human rib cage and to analyse the biomechanical performance of intact, injured and treated rib cages. Three-dimensional finite element models of the human rib cage were developed. Respiratory movement of the human rib cage was simulated to evaluate the strengths and limitations of different scenarios. The results show that a realistic human respiratory movement can be simulated and the predicted results were closely related to previous study (correlation coefficient>0.92). Fixation of two fractured ribs significantly decreased the fixation index (191%) compared to the injured model. This fixation may provide adequate fixation stability as well as reveal lower bone stress and implant stress compared with the fixation of three or more fractured ribs.
Walsh, W R; Svehla, M J; Russell, J; Saito, M; Nakashima, T; Gillies, R M; Bruce, W; Hori, R
2004-09-01
Implant surface roughness is an important parameter governing the overall mechanical properties at the implant-cement interface. This study investigated the influence of surface roughness using polymethylmethcrylate (PMMA) and a Bisphenol-a-glycidylmethacyrlate resin-hydroxyapatite cement (CAP). Mechanical fixation at the implant-cement interface was evaluated in vitro using static shear and fatigue loading with cobalt chrome alloy (CoCr) dowels with different surface roughness preparations. Increasing surface roughness improved the mechanical properties at the implant-cement interface for both types of cement. CAP cement fixation was superior to PMMA under static and dynamic loading.
Central Field Index Versus Visual Field Index for Central Visual Function in Stable Glaucoma.
Rao, Aparna; Padhy, Debananda; Mudunuri, Harika; Roy, Avik K; Sarangi, Sarada P; Das, Gopinath
2017-01-01
To compare the variability of central field index (CFI) versus visual field index (VFI) in stable glaucoma with central fixation involvement. For this retrospective study, we identified multiple visual fields (VFs) of patients with repeatable central fixation involvement on Humphrey VFs (24-2 and 10-2 program) which were stable (clinically and on VFs) over a very short period of 2 to 3 months. The VFI and CFI were calculated as described in earlier reports. We graded the fields as early [mean deviation (MD)>-6 dB], moderate (-6.1 to -12 dB), and severe glaucoma (<-12 dB) based on MD on 24-2 program. The variability of CFI and VFI between visits and across different severity of glaucoma was compared. Relation of the divergence to field indices and clinical parameters were assessed. The intervisit difference for VFI was greater than CFI ranging from -4% to 9% versus -1% to 8% in early (P=0.9), -13% to 18% versus -6% to 17% (P=0.056) in moderate, and -21% to 19% versus -9% to 9% (P<0.001) in severe glaucoma. The CFI within each group had narrower range than VFI with maximum range in severe glaucoma (33% to 95%). The divergence of CFI from VFI started at MD 24-2 beyond (worse) -10 dB. This difference between CFI and VFI was associated significantly with number of points with P<1% on 24-2 (R=80.3%). CFI is less variable than VFI in stable eyes with fixation involvement especially in severe glaucoma indicating need for incorporating CFI calculation for monitoring advanced disease in eyes with central defects.
Fan, Wei; Guo, Li-Xin
2018-06-01
Few studies have evaluated the need for supplementary instrumentation after lumbar interbody fusion under the condition of whole body vibration (WBV) that is typically present in vehicles. This study aimed to determine the effect of posterior pedicle screw fixation on dynamic response of the whole lumbar spine to vertical WBV after transforaminal lumbar interbody fusion (TLIF). A previously validated nonlinear, osteoligamentous finite element (FE) model of the intact L1-sacrum human lumbar spine was modified to simulate single-level (L4-L5) TLIF without and with bilateral pedicle screw fixation (BPSF). Transit dynamic analysis was performed on the 2 developed models under a sinusoidal vertical vibration load of ±40 N and a compressive follower preload of 400 N. The resulting dynamic response results for the 2 models in terms of stresses and deformations were recorded and compared. When compared with no fixation, BPSF decreased dynamic responses of the spinal levels to the vertical vibration after TLIF. At the fused level (L4-L5), vibration amplitudes of the von-Mises stresses in L4 inferior endplate and L5 superior endplate decreased after BPSF by 48.0% and 46.4%, respectively. At other disc levels (L1-L2, L2-L3, L3-L4, and L5-S1), vibration amplitudes of the disc bulge, von-Mises stress in annulus ground substance and intradiscal pressure also produced 4.2%-9.0%, 2.3%-8.9%, and 3.4%-8.8% deceases, respectively, after BPSF. After TLIF, application of BPSF can be helpful in the prevention of spine injury during vertical WBV. Copyright © 2018 Elsevier Inc. All rights reserved.
Houwert, Roderick M; Smeeing, Diederik P J; Ahmed Ali, Usama; Hietbrink, Falco; Kruyt, Moyo C; van der Meijden, Olivier A
2016-07-01
The last decade has shown a shift toward operative treatment of a subset of midshaft clavicle fractures. However, it is unclear whether there are differences between plate fixation and intramedullary fixation regarding complications and functional outcome. The aim of this systematic review and meta-analysis was to compare plate fixation and intramedullary fixation for midshaft clavicle fractures. The Medline, Embase, and Cochrane databases were searched for both randomized controlled trials and observational studies. The methodologic quality of all included studies was assessed using the Methodological Index for Non-Randomized Studies. Twenty studies were included. Ten of the 20 included studies used a fracture classification. Seven of these studies reported exclusion of patients with comminuted fractures. No difference in the total re-intervention rate was found (odds ratio [OR], 1.21; 95% confidence interval [CI], 0.71 to 2.04). Major re-interventions occurred more often after plate fixation (OR, 1.88; 95% CI, 1.02 to 3.46). The mean implant removal rates were 38% after plate fixation and 73% after intramedullary fixation. Re-fracture after implant removal occurred more often after plate fixation (OR, 3.42; 95% CI, 1.12 to 10.42). The Constant-Murley scores showed no differences at both short term (mean difference, -1.18; 95% CI, -13.41 to 11.05) and long term (mean difference, 0.15; 95% CI, -1.57 to 1.87). No differences were observed regarding nonunion (OR, 1.50; 95% CI, 0.82 to 2.75). The rate of infections showed no differences when outlier studies were excluded (OR, 1.54; 95% CI, 0.88 to 2.69). Major re-intervention and re-fracture after implant removal occurred more frequently after plate fixation of non-comminuted, displaced midshaft clavicle fractures. No differences in terms of function and nonunion between plate fixation and intramedullary fixation were observed. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Fixation Probability in a Haploid-Diploid Population.
Bessho, Kazuhiro; Otto, Sarah P
2017-01-01
Classical population genetic theory generally assumes either a fully haploid or fully diploid life cycle. However, many organisms exhibit more complex life cycles, with both free-living haploid and diploid stages. Here we ask what the probability of fixation is for selected alleles in organisms with haploid-diploid life cycles. We develop a genetic model that considers the population dynamics using both the Moran model and Wright-Fisher model. Applying a branching process approximation, we obtain an accurate fixation probability assuming that the population is large and the net effect of the mutation is beneficial. We also find the diffusion approximation for the fixation probability, which is accurate even in small populations and for deleterious alleles, as long as selection is weak. These fixation probabilities from branching process and diffusion approximations are similar when selection is weak for beneficial mutations that are not fully recessive. In many cases, particularly when one phase predominates, the fixation probability differs substantially for haploid-diploid organisms compared to either fully haploid or diploid species. Copyright © 2017 by the Genetics Society of America.
Formal properties of the probability of fixation: identities, inequalities and approximations.
McCandlish, David M; Epstein, Charles L; Plotkin, Joshua B
2015-02-01
The formula for the probability of fixation of a new mutation is widely used in theoretical population genetics and molecular evolution. Here we derive a series of identities, inequalities and approximations for the exact probability of fixation of a new mutation under the Moran process (equivalent results hold for the approximate probability of fixation under the Wright-Fisher process, after an appropriate change of variables). We show that the logarithm of the fixation probability has particularly simple behavior when the selection coefficient is measured as a difference of Malthusian fitnesses, and we exploit this simplicity to derive inequalities and approximations. We also present a comprehensive comparison of both existing and new approximations for the fixation probability, highlighting those approximations that induce a reversible Markov chain when used to describe the dynamics of evolution under weak mutation. To demonstrate the power of these results, we consider the classical problem of determining the total substitution rate across an ensemble of biallelic loci and prove that, at equilibrium, a strict majority of substitutions are due to drift rather than selection. Copyright © 2014 Elsevier Inc. All rights reserved.
Tan, Onder; Atik, Bekir; Dogan, Ali; Uslu, Mustafa; Alpaslan, Suleyman
2007-01-01
Skin grafting is widely used for the treatment of postburn contractures. Their main disadvantage, a tendency to contract again, can be reduced and better outcomes achieved by postoperative splinting. In this study we compared the outcomes of dynamic and static splinting postoperatively. Of the 57 patients managed by split grafts, 36 (44 hands) had Kirschner (K) wires applied with static splints, whereas 21 (26 hands) had dynamic splinting. The mean age was 11 (range 2-37) and 15 (range 2-50) years in the two groups. Before and after the operation, basic hand functions were evaluated clinically, and the results analysed statistically. The mean follow-up times were 18 and 14 months respectively, and recurrence rates were 22% and 14%. We think that the postoperative dynamic splinting is superior to fixation with K-wires with or without static splints.
Evaluating Silent Reading Performance with an Eye Tracking System in Patients with Glaucoma
Murata, Noriaki; Fukuchi, Takeo
2017-01-01
Objective To investigate the relationship between silent reading performance and visual field defects in patients with glaucoma using an eye tracking system. Methods Fifty glaucoma patients (Group G; mean age, 52.2 years, standard deviation: 11.4 years) and 20 normal controls (Group N; mean age, 46.9 years; standard deviation: 17.2 years) were included in the study. All participants in Group G had early to advanced glaucomatous visual field defects but better than 20/20 visual acuity in both eyes. Participants silently read Japanese articles written horizontally while the eye tracking system monitored and calculated reading duration per 100 characters, number of fixations per 100 characters, and mean fixation duration, which were compared with mean deviation and visual field index values from Humphrey visual field testing (24–2 and 10–2 Swedish interactive threshold algorithm standard) of the right versus left eye and the better versus worse eye. Results There was a statistically significant difference between Groups G and N in mean fixation duration (G, 233.4 msec; N, 215.7 msec; P = 0.010). Within Group G, significant correlations were observed between reading duration and 24–2 right mean deviation (rs = -0.280, P = 0.049), 24–2 right visual field index (rs = -0.306, P = 0.030), 24–2 worse visual field index (rs = -0.304, P = 0.032), and 10–2 worse mean deviation (rs = -0.326, P = 0.025). Significant correlations were observed between mean fixation duration and 10–2 left mean deviation (rs = -0.294, P = 0.045) and 10–2 worse mean deviation (rs = -0.306, P = 0.037), respectively. Conclusions The severity of visual field defects may influence some aspects of reading performance. At least concerning silent reading, the visual field of the worse eye is an essential element of smoothness of reading. PMID:28095478
Visual scan-path analysis with feature space transient fixation moments
NASA Astrophysics Data System (ADS)
Dempere-Marco, Laura; Hu, Xiao-Peng; Yang, Guang-Zhong
2003-05-01
The study of eye movements provides useful insight into the cognitive processes underlying visual search tasks. The analysis of the dynamics of eye movements has often been approached from a purely spatial perspective. In many cases, however, it may not be possible to define meaningful or consistent dynamics without considering the features underlying the scan paths. In this paper, the definition of the feature space has been attempted through the concept of visual similarity and non-linear low dimensional embedding, which defines a mapping from the image space into a low dimensional feature manifold that preserves the intrinsic similarity of image patterns. This has enabled the definition of perceptually meaningful features without the use of domain specific knowledge. Based on this, this paper introduces a new concept called Feature Space Transient Fixation Moments (TFM). The approach presented tackles the problem of feature space representation of visual search through the use of TFM. We demonstrate the practical values of this concept for characterizing the dynamics of eye movements in goal directed visual search tasks. We also illustrate how this model can be used to elucidate the fundamental steps involved in skilled search tasks through the evolution of transient fixation moments.
Stress analysis in a pedicle screw fixation system with flexible rods in the lumbar spine.
Kim, Kyungsoo; Park, Won Man; Kim, Yoon Hyuk; Lee, SuKyoung
2010-01-01
Breakage of screws has been one of the most common complications in spinal fixation systems. However, no studies have examined the breakage risk of pedicle screw fixation systems that use flexible rods, even though flexible rods are currently being used for dynamic stabilization. In this study, the risk of breakage of screws for the rods with various flexibilities in pedicle screw fixation systems is investigated by calculating the von Mises stress as a breakage risk factor using finite element analysis. Three-dimensional finite element models of the lumbar spine with posterior one-level spinal fixations at L4-L5 using four types of rod (a straight rod, a 4 mm spring rod, a 3 mm spring rod, and a 2 mm spring rod) were developed. The von Mises stresses in both the pedicle screws and the rods were analysed under flexion, extension, lateral bending, and torsion moments of 10 Nm with a follower load of 400 N. The maximum von Mises stress, which was concentrated on the neck region of the pedicle screw, decreased as the flexibility of the rod increased. However, the ratio of the maximum stress in the rod to the yield stress increased substantially when a highly flexible rod was used. Thus, the level of rod flexibility should be considered carefully when using flexible rods for dynamic stabilization because the intersegmental motion facilitated by the flexible rod results in rod breakage.
Nitrogen fixation dynamics of two diazotrophic communities in Mono Lake, California
Oremland, R.S.
1990-01-01
Two types of diazotrophic microbial communities were found in the littoral zone of alkaline hypersaline Mono Lake, California. One consisted of anaerobic bacteria inhabiting the flocculent surface layers of sediments. Nitrogen fixation (acetylene reduction) by flocculent surface layers occurred under anaerobic conditions, was not stimulated by light or by additions of organic substrates, and was inhibited by O2, nitrate, and ammonia. The second community consisted of a ball-shaped association of a filamentous chlorophyte (Ctenocladus circinnatus) with diazotrophic, nonheterocystous cyanobacteria, as well as anaerobic bacteria (Ctenocladus balls). Nitrogen fixation by Ctenocladus balls was usually, but not always, stimulated by light. Rates of anaerobic dark fixation equaled those in the light under air. Fixation in the light was stimulated by 3-(3,4-dichlorophenyl)-1,1-dimethylurea and by propanil [N-(3,4-dichlorophenyl)propanamide]. 3-(3,4-Dichlorophenyl)-1,1-dimethyl urea-elicited nitrogenase activity was inhibited by ammonia (96%) and nitrate (65%). Fixation was greatest when Ctenocladus balls were incubated anaerobically in the light with sulfide. Dark anaerobic fixation was not stimulated by organic substrates in short-term (4-h) incubations, but was in long-term (67-h) ones. Areal estimates of benthic N2 fixation were measured seasonally, using chambers. Highest rates (~29.3 ??mol of C2H4 m-2 h-1) occurred under normal diel regimens of light and dark. These estimates indicate that benthic N2 fixation has the potential to be a significant nitrogen source in Mono Lake.
Promotion of cooperation in evolutionary game dynamics with local information.
Liu, Xuesong; Pan, Qiuhui; He, Mingfeng
2018-01-21
In this paper, we propose a strategy-updating rule driven by local information, which is called Local process. Unlike the standard Moran process, the Local process does not require global information about the strategic environment. By analyzing the dynamical behavior of the system, we explore how the local information influences the fixation of cooperation in two-player evolutionary games. Under weak selection, the decreasing local information leads to an increase of the fixation probability when natural selection does not favor cooperation replacing defection. In the limit of sufficiently large selection, the analytical results indicate that the fixation probability increases with the decrease of the local information, irrespective of the evolutionary games. Furthermore, for the dominance of defection games under weak selection and for coexistence games, the decreasing of local information will lead to a speedup of a single cooperator taking over the population. Overall, to some extent, the local information is conducive to promoting the cooperation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Population turnover and adaptation in heterogeneous environments
NASA Astrophysics Data System (ADS)
Campos, Paulo R. A.; de Oliveira, Viviane M.
2012-02-01
We study adaptive dynamics in a structured population model of asexual individuals which takes into account environmental heterogeneity among the subpopulations. The key purpose of the present work is to address how population turnovers, i.e. extinction events followed by recolonization, affect the rate of fixation of advantageous mutations. This model is a generalization of our previous model to address the interplay between environmental correlation and evolutionary forces on the adaptive process. The incorporation of population turnovers into the model enables us to make a direct correspondence between the model and host-parasite dynamics (epidemiological models). Strikingly, contrary to the intuitive and usual deleterious effect associated to extinction events, it is observed that population turnovers can in fact speed up adaptation as heterogeneity rises. On the other side, in nearly homogeneous population turnovers have a neutral effect on fixation rates, but a detrimental outcome is also achieved when extinction events become very common. In resume, population turnover outcomes on fixation rates of advantageous mutations are strongly influenced by the selective correlation among the subpopulations (demes).
Chan, Gareth; Korac, Zelimir; Miletic, Matija; Vidovic, Dinko; Phadnis, Joideep; Bakota, Bore
2017-11-01
Surgical fixation of displaced midshaft clavicle fractures is predominantly achieved with intramedullary (IM) or plate fixation. Both techniques have potential pitfalls: plate fixation involves greater periosteal stripping and protuberance of the implant, whereas IM fixation may be associated with implant-related complications, such as migration or skin irritation, which may lead to further surgery for implant removal. The aim of this study was to compare these two methods in simple (Robinson 2b.1) and multifragmentary (Robinson 2b.2) displaced midshaft clavicle fractures. A total of 133 consecutive patients who underwent surgical fixation for a displaced midshaft clavicle fracture with either IM fixation using a 2.5-mm Kirschner wire or plate fixation using an 8-hole Dynamic Compression Plate (DCP) were retrospectively reviewed. Follow-up was a minimum of 1 year. The patients were allocated into two injury groups: displaced simple 2-part fractures (64 IM vs. 16 DCP) and displaced multifragmentary fractures (27 IM vs. 26 DCP). The major observed outcome measures were: infection rate, non-union rate, reoperation rate and postoperative range of motion (ROM). Rates of non-union for displaced 2-part fractures were 2/64 (3.13%) with IM fixation and 0/16 (0.00%) with plate fixation (p = 0.477). For displaced multifragmentary fractures, rates of non-union were 2/27 (7.41%) with IM fixation and 0/26 (0.00%) with plate fixation (p = 0.161). No significant difference was observed between the two fixation modalities in patient-reported time to regain ROM on the injured side for displaced 2-part fractures (p = 0.129) and displaced multifragmentary fractures (p = 0.070). Deep infection rate was zero (p = 1.000) overall in the study, and reoperation rate for IM and plate fixation, respectively, was 3.13% and 6.25% in the Robinson 2b.1 group (p = 0.559) and 7.41% and 7.69% in the Robinson 2b.2 group (p = 0.969). IM fixation of displaced midshaft clavicle fractures (Robinson 2b.1) has an equivalent non-union rate to plate fixation and similarly low complication and reoperation rates. For displaced midshaft multifragmentary clavicle fractures (Robinson 2b.2), the higher non-union rates observed with IM fixation leads us to recommend consideration of plate fixation for Robinson 2b.2 fractures. © 2017 Elsevier Ltd. All rights reserved.
Active visual search in non-stationary scenes: coping with temporal variability and uncertainty
NASA Astrophysics Data System (ADS)
Ušćumlić, Marija; Blankertz, Benjamin
2016-02-01
Objective. State-of-the-art experiments for studying neural processes underlying visual cognition often constrain sensory inputs (e.g., static images) and our behavior (e.g., fixed eye-gaze, long eye fixations), isolating or simplifying the interaction of neural processes. Motivated by the non-stationarity of our natural visual environment, we investigated the electroencephalography (EEG) correlates of visual recognition while participants overtly performed visual search in non-stationary scenes. We hypothesized that visual effects (such as those typically used in human-computer interfaces) may increase temporal uncertainty (with reference to fixation onset) of cognition-related EEG activity in an active search task and therefore require novel techniques for single-trial detection. Approach. We addressed fixation-related EEG activity in an active search task with respect to stimulus-appearance styles and dynamics. Alongside popping-up stimuli, our experimental study embraces two composite appearance styles based on fading-in, enlarging, and motion effects. Additionally, we explored whether the knowledge obtained in the pop-up experimental setting can be exploited to boost the EEG-based intention-decoding performance when facing transitional changes of visual content. Main results. The results confirmed our initial hypothesis that the dynamic of visual content can increase temporal uncertainty of the cognition-related EEG activity in active search with respect to fixation onset. This temporal uncertainty challenges the pivotal aim to keep the decoding performance constant irrespective of visual effects. Importantly, the proposed approach for EEG decoding based on knowledge transfer between the different experimental settings gave a promising performance. Significance. Our study demonstrates that the non-stationarity of visual scenes is an important factor in the evolution of cognitive processes, as well as in the dynamic of ocular behavior (i.e., dwell time and fixation duration) in an active search task. In addition, our method to improve single-trial detection performance in this adverse scenario is an important step in making brain-computer interfacing technology available for human-computer interaction applications.
Moran, Eduardo; Zderic, Ivan; Klos, Kajetan; Simons, Paul; Triana, Miguel; Richards, R Geoff; Gueorguiev, Boyko; Lenz, Mark
2017-10-01
Split fractures of the lateral tibia plateau in young patients with good bone quality are commonly treated using two minimally invasive percutaneous lag screws, followed by unloading of the knee joint. Improved stability could be achieved with the use of a third screw inserted either in the jail-technique fashion or with a triangular support screw configuration. The aim of this study was to investigate under cyclic loading the compliance and endurance of the triangular support fixation in comparison with the standard two lag-screw fixation and the jail technique. Lateral split fractures of type AO/OTA 41-B1 were created on 21 synthetic tibiae and subsequently fixed with one of the following three techniques for seven specimens: standard fixation by inserting two partially threaded 6.5 mm cannulated lag screws parallel to each other and orthogonal to the fracture plane; triangular support fixation-standard fixation with one additional support screw at the distal end of the fracture at 30° proximal inclination; and jail fixation-standard fixation with one additional orthogonal support screw inserted in the medial nonfractured part of the bone. Mechanical testing was performed under progressively increasing cyclic compression loading. Fragment displacement was registered via triggered radiographic imaging. Mean construct compliance was 3.847 × 10 -3 mm/N [standard deviation (SD) 0.784] for standard fixation, 3.838 × 10 -3 mm/N (SD 0.242) for triangular fixation, and 3.563 × 10 -3 mm/N (SD 0.383) for jail fixation, with no significant differences between the groups ( p = 0.525). The mean numbers of cycles to 2 mm fragment dislocation, defined as a failure criterion, were 12,384 (SD 2267) for standard fixation, 17,708 (SD 2193) for triangular fixation, and 14,629 (SD 5194) for jail fixation. Triangular fixation revealed significantly longer endurance than the standard one ( p = 0.047). Triangular support fixation enhanced interfragmentary stability at the ultimate stage of dynamic loading. However, the level of improvement seems to be limited and may not legitimate the intervention with an additional third screw.
Gupta, Sameer; Kukreja, Sunil; Singh, Vivek
2014-04-01
To review the outcome of 60 patients who underwent valgus subtrochanteric osteotomy and its repositioning for un-united and neglected femoral neck fractures. 60 patients (mean age, 35 years) underwent valgus subtrochanteric osteotomy and repositioning of the osteotomy and fixation with a dynamic hip screw and a 135° single-angled barrel plate for closed un-united femoral neck fractures after failed internal fixation (n=27) or neglected (>3 weeks) fractures (n=33). The most common fracture type was transcervical (n=48), followed by subcapital (n=6) and basal (n=6). All patients had displaced femoral neck fractures (Garden types 3 and 4). According to the Pauwel angle, 45 fractures were type 2 (30º-70º) and 15 were type 3 (>70º). Patients were followed up for a mean of 3.5 (range, 2-7.5) years. The mean Pauwel angle of the fracture was corrected from 65° (range, 50°-89°) to 26° (range, 25°-28°). Bone union was achieved in 56 patients after a mean of 3.9 (range, 3-5.5) months. The mean Harris hip score improved from 65 to 87.5. Outcome was excellent in 30 patients, good in 24, and poor in 6. Four of the patients developed avascular necrosis; 2 of whom nonetheless achieved a good outcome. Valgus osteotomy and repositioning and fixation with a dynamic hip screw and a 135° single-angled barrel plate was effective treatment for un-united and neglected femoral neck fractures.
Fixation stability of the upward gaze in patients with myasthenia gravis: an eye-tracker study
Mihara, Miharu; Hayashi, Atsushi; Fujita, Kazuya; Kakeue, Ken; Tamura, Ryoi
2017-01-01
Objective To quantify fixation stability of the upward gaze in patients with myasthenia gravis (MG) using an eye tracker. Methods and analysis In this study, 21 normal subjects, 5 patients with MG with diplopia, 5 patients with MG without diplopia and 6 patients with superior oblique (SO) palsy were included. Subjects fixated on a target in the upward direction for 1 min. The horizontal (X) and vertical (Y) eye positions were recorded using an eye tracker. Fixation stability was first quantified using the bivariate contour ellipse areas (BCEA) of fixation points as an index of whole stability. Then, the SDs of the X and Y eye positions (SDX and SDY, respectively) were quantified as indices of directional stability, with the data divided into three 20 s fractions to detect temporal fixation fluctuation. Results BCEAs were larger in patients with MG (both with and without diplopia) than normal subjects and patients with SO palsy, without significant differences among the three 20 s fractions. Compared with normal subjects, SDXs were larger only in patients with MG with diplopia; SDYs were larger in both patients with MG with and without diplopia. In addition, SDYs in patients with MG with diplopia were larger than those in patients with MG without diplopia and patients with SO palsy. Furthermore, a significant difference among the three 20 s fractions was detected for SDYs in patients with MG with diplopia. Conclusion Patients with MG, especially those with diplopia, exhibit fixation instability in the upward gaze. Non-invasive quantification of fixation stability with an eye tracker is useful for precisely identifying MG-specific fatigue characteristics. Trial registration number UMIN000023468; pre-results. PMID:29354719
Comparing the fixational and functional preferred retinal location in a pointing task
Sullivan, Brian; Walker, Laura
2016-01-01
Patients with central vision loss (CVL) typically adopt eccentric viewing strategies using a preferred retinal locus (PRL) in peripheral retina. Clinically, the PRL is defined monocularly as the area of peripheral retina used to fixate small stimuli. It is not clear if this fixational PRL describes the same portion of peripheral retina used during dynamic binocular eye-hand coordination tasks. We studied this question with four participants each with a unique CVL history. Using a scanning laser ophthalmoscope, we measured participants’ monocular visual fields and the location and stability of their fixational PRLs. Participants’ monocular and binocular visual fields were also evaluated using a computer monitor and eye tracker. Lastly, eye-hand coordination was tested over several trials where participants pointed to and touched a small target on a touchscreen monitor. Trials were blocked and carried out monocularly and binocularly, with a target appearing at 5° or 15° from screen center, in one of 8 locations. During pointing, our participants often exhibited long movement durations, an increased number of eye movements and impaired accuracy, especially in monocular conditions. However, these compensatory changes in behavior did not consistently worsen when loci beyond the fixational PRL were used. While fixational PRL size, location and fixation stability provide a necessary description of behavior, they are not sufficient to capture the pointing PRL used in this task. Generally, patients use a larger portion of peripheral retina than one might expect from measures of the fixational PRL alone, when pointing to a salient target without time constraints. While the fixational and pointing PRLs often overlap, the fixational PRL does not predict the large area of peripheral retina that can be used. PMID:26440864
NASA Astrophysics Data System (ADS)
Thomas, R. Q.; Williams, M.
2014-12-01
Carbon (C) and nitrogen (N) cycles are coupled in terrestrial ecosystems through multiple processes including photosynthesis, tissue allocation, respiration, N fixation, N uptake, and decomposition of litter and soil organic matter. Capturing the constraint of N on terrestrial C uptake and storage has been a focus of the Earth System modelling community. Here we explore the trade-offs and sensitivities of allocating C and N to different tissues in order to optimize the productivity of plants using a new, simple model of ecosystem C-N cycling and interactions (ACONITE). ACONITE builds on theory related to plant economics in order to predict key ecosystem properties (leaf area index, leaf C:N, N fixation, and plant C use efficiency) based on the optimization of the marginal change in net C or N uptake associated with a change in allocation of C or N to plant tissues. We simulated and evaluated steady-state and transient ecosystem stocks and fluxes in three different forest ecosystems types (tropical evergreen, temperate deciduous, and temperate evergreen). Leaf C:N differed among the three ecosystem types (temperate deciduous < tropical evergreen < temperature evergreen), a result that compared well to observations from a global database describing plant traits. Gross primary productivity (GPP) and net primary productivity (NPP) estimates compared well to observed fluxes at the simulation sites. A sensitivity analysis revealed that parameterization of the relationship between leaf N and leaf respiration had the largest influence on leaf area index and leaf C:N. Also, a widely used linear leaf N-respiration relationship did not yield a realistic leaf C:N, while a more recently reported non-linear relationship simulated leaf C:N that compared better to the global trait database than the linear relationship. Overall, our ability to constrain leaf area index and allow spatially and temporally variable leaf C:N can help address challenges simulating these properties in ecosystem and Earth System models. Furthermore, the simple approach with emergent properties based on coupled C-N dynamics has potential for use in research that uses data-assimilation methods to integrate data on both the C and N cycles to improve C flux forecasts.
NASA Astrophysics Data System (ADS)
Paulsen, Hanna; Ilyina, Tatiana; Six, Katharina D.; Stemmler, Irene
2017-03-01
Nitrogen (N2) fixation is a major source of bioavailable nitrogen to the euphotic zone, thereby exerting an important control on ocean biogeochemical cycling. This paper presents the incorporation of prognostic N2 fixers into the HAMburg Ocean Carbon Cycle model (HAMOCC), a component of the Max Planck Institute Earth System Model (MPI-ESM). Growth dynamics of N2 fixers in the model are based on physiological characteristics of the cyanobacterium Trichodesmium. The applied temperature dependency confines diazotrophic growth and N2 fixation to the tropical and subtropical ocean roughly between 40°S and 40°N. Simulated large-scale spatial patterns compare well with observations, and the global N2 fixation rate of 135.6 Tg N yr-1 is within the range of current estimates. The vertical distribution of N2 fixation also matches well the observations, with a major fraction of about 85% occurring in the upper 20 m. The observed seasonal variability at the stations BATS and ALOHA is reasonably reproduced, with highest fixation rates in northern summer/fall. Iron limitation was found to be an important factor in controlling the simulated distribution of N2 fixation, especially in the Pacific Ocean. The new model component considerably improves the representation of present-day N2 fixation in HAMOCC. It provides the basis for further studies on the role of diazotrophs in global biogeochemical cycles, as well as on the response of N2 fixation to changing environmental conditions.
NASA Astrophysics Data System (ADS)
Dong, Yansheng; Wang, Yongqing; Dong, Limin; Jia, Peng; Lu, Fengcheng
2017-07-01
The nail with absorbable sheath (AS nail) is designed to reduce the stress shielding effect of internal fixation with interlocking intramedullary nail. In order to verify its feasibility, two types of the finite element models of internal fixation of tibia with the AS nail and the common metal nail (CM nail) are established using the Softwares of Mimics, Geomagic, SolidWorks and ANSYS according to the CT scanning data of tibia. The result of the finite element analysis shows that the AS nail has great advantages compared with the CM nail in reducing the stress shielding effect in different periods of fracture healing. The conclusion is that the AS nail can realize the static fixation to the dynamic fixation from the early to the later automatically to shorten the time of fracture healing, which also provides a new technique to the interlocking intramedullary nail.
Fixation of slightly beneficial mutations: effects of life history.
Vindenes, Yngvild; Lee, Aline Magdalena; Engen, Steinar; Saether, Bernt-Erik
2010-04-01
Recent studies of rates of evolution have revealed large systematic differences among organisms with different life histories, both within and among taxa. Here, we consider how life history may affect the rate of evolution via its influence on the fixation probability of slightly beneficial mutations. Our approach is based on diffusion modeling for a finite, stage-structured population with stochastic population dynamics. The results, which are verified by computer simulations, demonstrate that even with complex population structure just two demographic parameters are sufficient to give an accurate approximation of the fixation probability of a slightly beneficial mutation. These are the reproductive value of the stage in which the mutation first occurs and the demographic variance of the population. The demographic variance also determines what influence population size has on the fixation probability. This model represents a substantial generalization of earlier models, covering a large range of life histories.
Wiens, Stefan; Sand, Anders; Norberg, Joakim; Andersson, Per
2011-05-20
Viewing of emotional pictures elicits two event-related potentials (ERPs) to emotional versus neutral pictures: an early posterior negativity (EPN) and a late positive potential (LPP). Because it is unresolved whether these indexes of emotional processing are reduced to task-irrelevant pictures at fixation, negative and neutral pictures from the International Affective Picture Set (IAPS) were shown at fixation together with 6 letters that surrounded the pictures. In separate tasks, participants were instructed to attend either the pictures or the letters. When the pictures were task relevant, results showed an EPN and LPP. In contrast, when the pictures were task irrelevant, the EPN was eliminated and the LPP reduced. Performance was high in both tasks (hit rates>87%), but somewhat better when the pictures were relevant. However, analyses showed no relationship between this performance difference and the differences in EPN and LPP between tasks. These results suggest that emotional processing of strong, negative pictures is sensitive to manipulations of attention even if the pictures are shown at fixation. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Preparation of forefinger's sequence on keyboard orients ocular fixations on computer screen.
Coutté, Alexandre; Olivier, Gérard; Faure, Sylvane; Baccino, Thierry
2014-08-01
This study examined the links between attention, hand movements and eye movements when performed in different spatial areas. Participants performed a visual search task on a computer screen while preparing to press two keyboard keys sequentially with their index. Results showed that the planning of the manual sequence influenced the latency of the first saccade and the placement of the first fixation. In particular, even if the first fixation placement was influenced by the combination of both components of the prepared manual sequence in some trials, it was affected principally by the first component of the prepared manual sequence. Moreover, the probability that the first fixation placement did reflect a combination of both components of the manual sequence was correlated with the speed of the second component. This finding suggests that the preparation of the second component of the sequence influence simultaneous oculomotor behavior when motor control of the manual sequence relied on proactive motor planning. These results are discussed taking into account the current debate on the eye/hand coordination research.
Fractures of the growing mandible.
Kushner, George M; Tiwana, Paul S
2009-03-01
Oral and maxillofacial surgeons must constantly weigh the risks of surgical intervention for pediatric mandible fractures against the wonderful healing capacity of children. The majority of pediatric mandibular fractures can be managed with closed techniques using short periods of maxillomandibular fixation or training elastics alone. Generally, the use of plate- and screw-type internal fixation is reserved for difficult fractures. This article details general and special considerations for this surgery including: craniofacial growth & development, surgical anatomy, epidemiology evaluation, various fractures, the role rigid internal fixation and the Risdon cable in pediatric maxillofacial trauma. It concludes with suggestions concerning long-term follow-up care in light of the mobility, insurance obstacles, and family dynamics facing the patient population.
Kulkarni, Ruta; Singh, Nishant; Kulkarni, Govind S; Kulkarni, Milind; Kulkarni, Sunil; Kulkarni, Vidisha
2012-01-01
Background: The limb lengthening over plate eliminates the associated risk of infection with limb lengthening over intramedullary nail. We present our experience of limb lengthening in 15 patients with a plate fixed on the proximal segment, followed by corticotomy and application of external fixator. Materials and Methods: 15 patients (7 females, 8 males) were included in this consecutive series. The average age was 18.1 years (range 8–35 years). Fifteen tibiae and one femur were lengthened in 15 patients. Lengthening was achieved at 1 mm/day followed by distal segment fixation with three or four screws on reaching the target length. Results: The preoperative target length was successfully achieved in all patients at a mean of 4.1 cm (range 1.8–6.5 cm). The mean duration of external fixation was 75.3 days (range 33–116 days) with the mean external fixation index at 19.2 days/cm (range 10.0–38.3 days/cm). One patient suffered deep infection up to the plate, three patients had mild procurvatum deformities, and one patient developed mild tendo achilles contracture. Conclusion: Lengthening over a plate allows early removal of external fixator and eliminates the risk of creating deep intramedullary infection as with lengthening over nail. Lengthening over plate is also applicable to children with open physis. PMID:22719123
Madey, Steven M; Tsai, Stanley; Fitzpatrick, Daniel C; Earley, Kathleen; Lutsch, Michael; Bottlang, Michael
2017-01-01
Rigid locked plating constructs can suppress fracture healing by inhibiting interfragmentary motion required to stimulate natural bone healing by callus formation. Dynamic fixation with active locking plates reduces construct stiffness, enables controlled interfragmentary motion, and has been shown to induce faster and stronger bone healing in vivo compared to rigid locking plates. This prospective observational study represents the first clinical use of active locking plates. It documents our early clinical experience with active plates for stabilization of humeral shaft fractures to assess their durability and understand potential complications. Eleven consecutive patients with humeral shaft fractures (AO/OTA types 12 A-C) were prospectively enrolled at a level I and a level II trauma center. Fractures were stabilized by using active locking plates without supplemental bone graft or bone morphogenic proteins. The screw holes of active locking plates are elastically suspended in elastomer envelopes inside the plate, enabling up to 1.5 mm of controlled interfragmentary motion. Progression of fracture healing and integrity of implant fixation was assessed radiographically at 3, 6, 12, and 24 weeks post surgery. Patient-reported functional outcome measures were obtained at 6, 12, and 24 weeks post surgery. The primary endpoint of this study was plate durability in absence of plate bending or breakage, or failure of the elastically suspended locking hole mechanism. Secondary endpoints included fracture healing, complications requiring revision surgery, and functional outcome scores. The eleven patients had six simple AO/ OTA type 12A fractures, three wedge type 12B fractures, and two comminuted type 12C fracture, including one open fracture. All active locking plates endured the 6-month loading period without any signs of fatigue or failure. Ten of eleven fractures healed at 10.9 ± 5.2 weeks, as evident by bridging callus and pain-free function. One fracture required revision surgery 37 weeks post surgery due to late fixation failure at the screwbone interface in the presence of a atrophic delayed union. The average Disability of the Arm, Shoulder and Hand (DASH) score improved from 31 ± 22 at week 6 to 13 ± 15 by week 24, approaching that of the normal, healthy population (DASH = 10.1). By week 12, the difference between Constant shoulder scores, expressed as the difference between the affected and contralateral arm (8 ± 8), was considered excellent. By week 24, the SF-12 physical health score (44 ± 9) and mental health score (48 ± 11) approached the mean value of 50 that represents the norm for the general U.S. population. Absence of failure of the plate and locking holes suggests that dynamic fixation of humeral shaft fractures with active plates provides safe and effective fixation. Moreover, early callus bridging and excellent functional outcome scores suggest that dynamic fixation with active locking plates may promote increased fracture healing over standard locked plating.
Badaracco, Carlo; Labini, Francesca Sylos; Meli, Annalisa; De Angelis, Ezio; Tufarelli, Davide
2007-09-01
To evaluate the efficiency of the rehabilitative protocols in patients with labyrinthine hypofunction, focusing on computerized dynamic visual acuity test (DVAt) and Gaze stabilization test (GST) specifically evaluating the vestibulo-oculomotor reflex (VOR) changes due to vestibular rehabilitation. Consecutive sample study. Day hospital in Ears, Nose, and Throat Rehabilitation Unit. Thirty-two patients with chronic dizziness with a mean age of 60.74 years. Patients performed one cycle of 12 daily rehabilitation sessions (2 h each) consisting of exercises aimed at improving VOR gain. The rehabilitation program included substitutional and/or habitudinal exercises, exercises on a stability platform, and exercises on a moving footpath with rehabilitative software. Dizziness Handicap Inventory and Activities-specific Balance Confidence Scale. Computerized dynamic posturography, computerized DVAt, and GST. The patients significantly improved in all the tests. Vestibular rehabilitation improved the quality of life by reducing the handicap index and improving the ability in everyday tasks. The recovery of the vestibular-ocular reflex and vestibular-spinal reflex efficiency was objectively proven by instrumental testing. The DVAt and the GST allow to objectively quantify the fixation ability at higher frequencies and speeds (main VOR function). Moreover, these new parameters permit to completely evaluate vestibular rehabilitation outcomes, adding new information to the generally used tests that only assess vestibulospinal reflex.
Yoo, Gyeol; Rha, Eun Young; Jeong, Jin Yong; Lee, Jongho; Sim, Sung Bo; Jo, Keon Hyon
2016-01-01
Bar flipping displacement is one of the most common complications after the Nuss procedure for pectus excavatum. We evaluated the results of a modified Nuss procedure with needlescope-assisted bar fixation. The records of 41 patients with pectus excavatum who underwent single pectus bar insertion with the Nuss procedure between July 2011 and August 2014 were retrospectively reviewed. The patients were divided into two groups: those who did not undergo 3-point fixation (group A) and those who did undergo 3-point fixation (group B). There were 36 male patients and 5 female patients with a mean age of 10.7 ± 8.3 years (range: 3-36 years). The postoperative Haller index (HI) (2.61 ± 0.42) was significantly lower than the preoperative HI (3.91 ± 1.07; p < 0.01). The angle of the initial bar position was 5.59 ± 7.37 degrees in group A and 8.52 ± 9.61 degrees in group B, with no significant difference between the groups (p > 0.05). The rate of reoperation to correct bar displacement was lower in group B (3.3%) than in group A (9.1%). Needlescope-assisted 3-point fixation of the bar was performed without an additional skin incision and showed a low rate of reoperation to correct displacement of the pectus bar. Georg Thieme Verlag KG Stuttgart · New York.
Murray, Lee; Mobegi, Victor A; Duffy, Craig W; Assefa, Samuel A; Kwiatkowski, Dominic P; Laman, Eugene; Loua, Kovana M; Conway, David J
2016-05-12
In regions where malaria is endemic, individuals are often infected with multiple distinct parasite genotypes, a situation that may impact on evolution of parasite virulence and drug resistance. Most approaches to studying genotypic diversity have involved analysis of a modest number of polymorphic loci, although whole genome sequencing enables a broader characterisation of samples. PCR-based microsatellite typing of a panel of ten loci was performed on Plasmodium falciparum in 95 clinical isolates from a highly endemic area in the Republic of Guinea, to characterize within-isolate genetic diversity. Separately, single nucleotide polymorphism (SNP) data from genome-wide short-read sequences of the same samples were used to derive within-isolate fixation indices (F ws), an inverse measure of diversity within each isolate compared to overall local genetic diversity. The latter indices were compared with the microsatellite results, and also with indices derived by randomly sampling modest numbers of SNPs. As expected, the number of microsatellite loci with more than one allele in each isolate was highly significantly inversely correlated with the genome-wide F ws fixation index (r = -0.88, P < 0.001). However, the microsatellite analysis revealed that most isolates contained mixed genotypes, even those that had no detectable genome sequence heterogeneity. Random sampling of different numbers of SNPs showed that an F ws index derived from ten or more SNPs with minor allele frequencies of >10 % had high correlation (r > 0.90) with the index derived using all SNPs. Different types of data give highly correlated indices of within-infection diversity, although PCR-based analysis detects low-level minority genotypes not apparent in bulk sequence analysis. When whole-genome data are not obtainable, quantitative assay of ten or more SNPs can yield a reasonably accurate estimate of the within-infection fixation index (F ws).
Fu, Lin; Ma, Jianxiong; Lu, Bin; Jia, Haobo; Zhao, Jie; Kuang, Mingjie; Feng, Rui; Xu, Liyan; Bai, Haohao; Sun, Lei; Wang, Ying; Ma, Xinlong
2017-07-01
Pedicle screw fixation may induce abnormal activity at adjacent segment and accelerate the degeneration of lumbar vertebrae. Dynamic stabilizers could provide an intermediate solution between conservative treatment and fusion surgery. Lumbar vertebral segment cephalad to instrumented fixation was the most common localization of adjacent segment degeneration. The aim of this study is to explore the use of interspinous process devices in the lumbar vertebral segment cephalad to fixation segment in changing the mechanical distribution and limiting abnormal activity of the spine. Eight specimens were tested in the following groups: intact group, instability group (bilateral facetectomy at L3-L4), fixation group (bilateral facetectomy and pedicle screw fixation at L3-L4), and hybrid fixation group (fixation at L3-L4 and simulating interspinous device implantation of 6, 8, 10, 12, 14, 16, and 18 mm at L2-L3). Range of motion, motion of vertebral body, and strain distribution change were recorded. The range of motion in extension with 16- and 18-mm hybrid constructs was significantly lower than intact, instability, and fixation groups. In flexion and lateral bending, the strain values of L4 inferior articular process with 18-mm hybrid construct have a significant difference compared with other groups. In axial rotation, under the condition of a contralateral state, the strain values of L2 superior articular process with 18-mm hybrid construct have a significant difference compared with intact and fixation groups. The strain value of the L4 inferior articular process had negative correlation with height distraction in three dimensions, except extension. A negative correlation between the strain value of the L2 superior articular process and distraction height was found in contralateral bending and contralateral axial rotation. Interspinous process devices above the fixation segment can change the mechanical distribution of the spine and limit activity in some of the segments of the spine, which may delay the degeneration of the adjacent segment.
Glacial-Interglacial and Holocene N2O Stable Isotope Changes Constrain Terrestrial N Cycling
NASA Astrophysics Data System (ADS)
Schmitt, J.; Spahni, R.; Bock, M.; Seth, B.; Stocker, B. D.; Ri, X.; Schilt, A.; Brook, E.; Otto-Bliesner, B. L.; Liu, Z.; Prentice, I. C.; Fischer, H.; Joos, F.
2015-12-01
The land biosphere contributes most to the natural source of the long-lived greenhouse gas nitrous oxide (N2O), with N2O emissions being dependent on the turnover rate of both the terrestrial nitrogen (N) and carbon (C) cycle. The C:N stoichiometry of vegetation and soil organic matter links the cycles intimately. Sustained plant productivity increase must be supported by biological N fixation. Intensified N cycling in turn enhances N loss and thereby N2O emissions. The temporal and spatial dynamics of terrestrial N and C cycles and related terrestrial N2O emissions are poorly constrained over the glacial-interglacial transition and the Holocene. Here we reconstruct increased terrestrial N2O emissions since the Last Glacial Maximum based on N2O concentration and isotope measurements on several ice cores and show that this N2O increase can be explained by N cycle modelling - provided N fixation is allowed to respond dynamically to increasing N demand and turnover. The Ice core reconstructions suggest a deglacial increase of 1.1 ± 0.4 Tg N/yr in terrestrial and 0.6 ± 0.4 Tg/yr in oceanic N2O emissions, but relatively constant terrestrial emissions over the Holocene. Transient simulations with a Dynamic Global Vegetation Model are shown to represent the climate and CO2 induced changes in terrestrial N2O emission, and suggest a deglacial increase in biological N fixation by 20%, independently of its absolute magnitude. Deciphering the response of biological N fixation during climatic changes is an important factor for our understanding of plant growth and the land carbon sink, alongside anthropogenic greenhouse gas emissions.
Veldre, Aaron; Andrews, Sally
2014-01-01
Two experiments used the gaze-contingent moving-window paradigm to investigate whether reading comprehension and spelling ability modulate the perceptual span of skilled adult readers during sentence reading. Highly proficient reading and spelling were both associated with increased use information to the right of fixation, but did not systematically modulate the extraction of information to the left of fixation. Individuals who were high in both reading and spelling ability showed the greatest benefit from window sizes larger than 11 characters, primarily because of increases in forward saccade length. They were also significantly more disrupted by being denied close parafoveal information than those poor in reading and/or spelling. These results suggest that, in addition to supporting rapid lexical retrieval of fixated words, the high quality lexical representations indexed by the combination of high reading and spelling ability support efficient processing of parafoveal information and effective saccadic targeting.
Babiloni, Francesca; Rossi, Dario; Cherubino, Patrizia; Trettel, Arianna; Picconi, Daniela; Maglione, Anton Giulio; Vecchiato, Giovanni; de Vico Fallani, Fabrizio; Chavez, Mario; Babiloni, Fabio
2015-08-01
In this paper we measured the neuroelectrical and the eye-movements activities in a group of 27 healthy subjects during their visit of a fine arts gallery in which a series of masterpieces of the Italian painter Tiziano Vecellio (also known as Titian, 1488-1576) were shown. The pictures chosen for the visit were 10 portraits and 10 of religious subjects. Each picture was observed for a minute. A mobile EEG device with an eye-tracker was used for this experiment. Evaluation of the appreciation of the pictures was performed by using the neuroelectrical approach-withdrawal index (AW). High value of AW means high appreciation of the picture. The number of eye fixations performed by the subjects during the observation of the pictures was also analyzed. Results showed that in the examined group the AW index was significant higher during the observation of portraits than during the observation of the religious subjects (as resulted from an ANOVA performed on AW index, with a p<;0,007). Interestingly, the average AW index estimated in the first 20 seconds of the observation of the pictures remains highly correlated with the AW index evaluated for the second part of the data (from 20 s to one minute) for all the 20 pictures examined (r = 0,82, p<;0,0001). In addition, the number of eye fixations performed by the subjects in the first 5 or 10 seconds of observation of the pictures that were most appreciated are significantly higher than the number of eye fixations performed on pictures that subjects did not like (p<;0,048 and p<;0,0018, respectively). Such difference vanishes if the entire period of observation of the pictures of one minute is used (p = 0,54). Taken together, such results seem to suggest that the neuroelectrical correlates of the perception of "good" or "bad" pictures are rapidly formed in our brain, within the first 10-20 seconds from the exposition to the picture.
Evolutionary dynamics on graphs
NASA Astrophysics Data System (ADS)
Lieberman, Erez; Hauert, Christoph; Nowak, Martin A.
2005-01-01
Evolutionary dynamics have been traditionally studied in the context of homogeneous or spatially extended populations. Here we generalize population structure by arranging individuals on a graph. Each vertex represents an individual. The weighted edges denote reproductive rates which govern how often individuals place offspring into adjacent vertices. The homogeneous population, described by the Moran process, is the special case of a fully connected graph with evenly weighted edges. Spatial structures are described by graphs where vertices are connected with their nearest neighbours. We also explore evolution on random and scale-free networks. We determine the fixation probability of mutants, and characterize those graphs for which fixation behaviour is identical to that of a homogeneous population. Furthermore, some graphs act as suppressors and others as amplifiers of selection. It is even possible to find graphs that guarantee the fixation of any advantageous mutant. We also study frequency-dependent selection and show that the outcome of evolutionary games can depend entirely on the structure of the underlying graph. Evolutionary graph theory has many fascinating applications ranging from ecology to multi-cellular organization and economics.
Han, Kihwan; Yeo, Hyeonjung; Choi, Tae Hyun; Son, Daegu; Kim, Jun Hyung
2010-03-01
One of the most common complications of double eyelid operations is asymmetry. To reduce asymmetry, we fixed the dermis to the tarsal plate at the same level as the skin incision, and objectively evaluated the symmetry of the height using photogrammetry.Of 30 patients who had double eyelid operations by the intratarsal fixation technique, 15 patients completed a minimum follow-up of 6 months. After the skin incision and removal of the orbicularis oculi muscle and the orbital fat, the pretarsal fat pad was excised to expose the superior portion of the tarsal plate. The 3 fixation points were marked on the tarsal plate at the same level with the skin incision using a spreading caliper. The dermis was fixed to the marked points of the tarsal plate and the skin was closed.The height of the double eyelid was measured by clinical photography at 4 points when the eyes were opened and at 3 points when the eyes were closed. The height proportional index at each point was obtained by dividing the height of the left double eyelid by that of the right double eyelid. We compared each height proportional index with "1" to evaluate the symmetry of both double eyelids using a paired t test.The follow-up period was an average of 9.0 months. The mean height proportional indices were 0.97 (a), 0.96 (b), 0.98 (c), 1.08 (d), 0.97 (e), 1.02 (f), and 1.13 (g). According to a paired t test, the height of the left double eyelid was not different from that of the right double eyelid.Intratarsal fixation, along with other previously known methods, decreases asymmetric double eyelids.
Implant Removal After Internal Fixation of a Femoral Neck Fracture: Effects on Physical Functioning.
Zielinski, Stephanie M; Heetveld, Martin J; Bhandari, Mohit; Patka, Peter; Van Lieshout, Esther M M
2015-09-01
The effect of implant removal after internal fixation of a femoral neck fracture on physical functioning was analyzed. Characteristics of patients who had their implant removed were studied, as it is currently unknown from which type of patients implants are removed and what effect removal has on function. Secondary cohort study alongside a randomized controlled trial. Multicenter study in 14 hospitals. Patients who had their implant removed after internal fixation of a femoral neck fracture are compared with patients who did not. Patient characteristics and quality of life (Short Form 12, Western Ontario McMaster Osteoarthritis Index) were compared. Matched pairs were selected based on patient/fracture characteristics and prefracture physical functioning. Of 162 patients, 37 (23%) had their implant removed. These patients were younger (median age: 67 vs. 72 years, P = 0.024) and more often independently ambulatory prefracture (100% vs. 84%, P = 0.008) than patients who did not. They more often had evident implant back-out on x-rays (54% vs. 34%, P = 0.035), possibly related to a higher rate of Pauwels 3 fractures (41% vs. 22%, P = 0.032). In time, quality of life improved more in implant removal patients [+2 vs. -4 points, Short Form 12 (physical component), P = 0.024; +9 vs. 0 points, Western Ontario McMaster Osteoarthritis Index, P = 0.019]. Implant removal after internal fixation of a femoral neck fracture positively influenced quality of life. Implant removal patients were younger and more often independently ambulatory prefracture, more often had a Pauwels 3 fracture, and an evident implant back-out. Implant removal should be considered liberally for these patients if pain persists or functional recovery is unsatisfactory. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.
Stoikes, Nathaniel; Webb, David; Powell, Ben; Voeller, Guy
2013-11-01
The Rives repair for ventral/incisional (V/I) hernias involves sublay mesh placement requiring retrorectus dissection and transfascial stitches. Chevrel described a repair by onlaying mesh after a unique primary fascial closure. Although Chevrel fixated mesh to the anterior fascia with sutures, he used fibrin glue for fascial closure reinforcement. We describe an onlay technique with mesh fixated to the anterior fascia solely with fibrin glue without suture fixation. From January 2010 to January 2012, 50 patients underwent a V/I hernia onlay technique with fibrin glue mesh fixation. Records were reviewed for technical details, demographics, mesh characteristics, and postoperative outcomes. Primary fascial closure with interrupted permanent suture was done with or without myofascial advancement flaps. Onlay polypropylene mesh was placed providing 8 cm of overlap. Fibrin glue was applied over the prosthesis and subcutaneous drains were placed. Mean age was 62.4 years. Mean body mass index was 30.1 kg/m(2). Average mesh size was 14.5 cm × 19.1 cm. Mean operative time was 144.4 minutes (range, 38 to 316 minutes). Mean discharge was postoperative Day 2.9 (range, 0 to 15 days). Morbidity included eight seromas, one hematoma, and three wound infections. Seventeen patients required components separation. Mean follow-up was 19.5 months with no recurrences. This is the first series describing fibrin glue alone for mesh fixation for V/I hernia repair. It allows for immediate prosthesis fixation to the anterior fascia. Early results are promising. Potential advantages include less operative time, less technical difficulty, and less long-term pain. A prospective trial is needed to evaluate this approach.
Kiene, J; Schulz, Arndt P; Hillbricht, S; Jürgens, Ch; Paech, A
2009-01-28
The methods for ankle arthrodesis differ significantly, probably a sign that no method is clearly superior to others. In the last ten years there is a clear favour toward internal fixation. We retrospectively evaluate the technique and evaluate the clinical long term results of external fixation in a triangular frame. From 1994 to 2001 a consecutive series of 95 patients with end stage arthritis of the ankle joint were treated. Retrospectively the case notes were evaluated regarding trauma history, medical complaints, further injuries and illnesses, walking and pain status and occupational issues and the clinical examination before arthrodesis. Mean age at the index procedure was 45.4 years (18-82), 67 patients were male (70.5%). Via a bilateral approach the malleoli and the joint surfaces were resected. An AO fixator was applied with two Steinmann-nails inserted with approximately 8 cm distance in the distal tibia, one in the neck of the talus and one in the dorsal calcaneus. The fixator was removed after approximately 12 weeks. Follow up examination at mean 4.4 years included a standardised questionnaire and a clinical examination including the criteria of the AOFAS-Score and radiographs. Due to different complications, 8 (8.9%) further surgical procedures were necessary including 1 below knee amputation. In 4 patients a non-union of the ankle arthrodesis developed (4.5%). The mean AOFAS score improved from 20.8 to 69.3 points. Non-union rates and clinical results of arthrodesis by triangular external fixation of the ankle joint do not differ to internal fixation methods. The complication rate and the reduced patient comfort reserve this method mainly for infected arthritis and complicated soft tissue situations.
2009-01-01
The methods for ankle arthrodesis differ significantly, probably a sign that no method is clearly superior to others. In the last ten years there is a clear favour toward internal fixation. We retrospectively evaluate the technique and evaluate the clinical long term results of external fixation in a triangular frame. Patients and Methods From 1994 to 2001 a consecutive series of 95 patients with end stage arthritis of the ankle joint were treated. Retrospectively the case notes were evaluated regarding trauma history, medical complaints, further injuries and illnesses, walking and pain status and occupational issues and the clinical examination before arthrodesis. Mean age at the index procedure was 45.4 years (18-82), 67 patients were male (70.5%). Via a bilateral approach the malleoli and the joint surfaces were resected. An AO fixator was applied with two Steinmann-nails inserted with approximately 8 cm distance in the distal tibia, one in the neck of the talus and one in the dorsal calcaneus. The fixator was removed after approximately 12 weeks. Follow up examination at mean 4.4 years included a standardised questionnaire and a clinical examination including the criteria of the AOFAS-Score and radiographs. Results: Due to different complications, 8 (8.9%) further surgical procedures were necessary including 1 below knee amputation. In 4 patients a non-union of the ankle arthrodesis developed (4.5%). The mean AOFAS score improved from 20.8 to 69.3 points. Conclusion Non-union rates and clinical results of arthrodesis by triangular external fixation of the ankle joint do not differ to internal fixation methods. The complication rate and the reduced patient comfort reserve this method mainly for infected arthritis and complicated soft tissue situations. PMID:19258207
NASA Astrophysics Data System (ADS)
Kicklighter, D. W.; Melillo, J. M.; Monier, E.; Sokolov, A. P.; Lu, X.; Zhuang, Q.
2015-12-01
Atmospheric nitrogen deposition, nitrogen fixation, and the application of nitrogen fertilizers provide subsidies to land ecosystems that can increase nitrogen availability for vegetation production and thereby influence land carbon dynamics. In addition, enhanced decomposition of soil organic matter (SOM) from warming soils and permafrost degradation may also increase nitrogen availability in Northern Eurasia. Here, we examine how changes in nitrogen availability may influence land carbon dynamics in Northern Eurasia during the 21st century by comparing results for a "business as usual" scenario (the IPCC Representative Concentration Pathways or RCP 8.5) and a stabilization scenario (RCP 4.5) between a version of the Terrestrial Ecosystem Model that does not consider the effects of atmospheric nitrogen deposition, nitrogen fixation and soil thermal dynamics on land carbon dynamics (TEM 4.4) and a version that does consider these dynamics (TEM 6.0). In these simulations, atmospheric nitrogen deposition, nitrogen fixation, and fertilizer applications provide an additional 3.3 Pg N (RCP 4.5) to 3.9 Pg N (RCP 8.5) to Northern Eurasian ecosystems over the 21st century. Land ecosystems retain about 38% (RCP4.5) to 48% (RCP 8.5) of this nitrogen subsidy. Net nitrogen mineralization estimated by TEM 6.0 provide an additional 1.0 Pg N to vegetation than estimated by TEM 4.4 over the 21st century from enhanced decomposition of SOM including SOM formerly protected by permafrost. The enhanced nitrogen availability in TEM 6.0 allows Northern Eurasian ecosystems to sequester 1.8x (RCP 8.5) to 2.4x (RCP 4.5) more carbon over the 21st century than estimated by TEM 4.4. Our results indicate that consideration of nitrogen subsidies and soil thermal dynamics have a large influence on how simulated land carbon dynamics in Northern Eurasia will respond to future changes in climate, atmospheric chemistry, and disturbances.
Petsatodis, George; Chatzisymeon, Apostolos; Antonarakos, Petros; Givissis, Panagiotis; Papadopoulos, Pericles; Christodoulou, Anastasios
2010-04-01
To compare outcomes of 3 fixation techniques for intra-articular distal femoral fractures. Records of 59 men and 49 women aged 16 to 80 (mean, 47) years who underwent internal fixation for 116 type-C (complete intra-articular) distal femoral fractures were retrospectively reviewed. According to the AO classification, 25 fractures were type C1 (23 closed and 2 open), 71 type C2 (69 closed and 2 open), and 20 type C3 (16 closed and 4 open). Based on implant availability at the time, all surgeries were performed by a single surgeon using a condylar buttress plate (n=38), a fixed angle (95 degrees) condylar blade plate (n=24), or a dynamic condylar screw (n=54). The mean follow-up period was 11 (range, 4-19) years. At the latest follow-up, functional outcome was classified according to Schatzker and Lambert criteria. Functional outcomes were excellent in 64 (55%) of the fractures, good in 37 (32%), moderate in 9 (8%), and poor in 6 (5%). Outcomes in patients treated by the dynamic condylar screw were significantly superior to those treated by the condylar buttress plate (p=0.016) or condylar blade plate (p=0.001). Good-to-excellent results were achieved in 96% vs 84% vs 71% of these patients, respectively. Complication rates were lower in the dynamic condylar screw group than the other 2 groups (pseudarthrosis, 5% vs 11% vs 25%; varus deformity, 4% vs 26% vs 25%; knee stiffness, 0% vs 5% vs 8%, respectively). No implant failure was encountered. Dynamic condylar screw fixation for distal femoral fractures achieves better functional outcomes and lower complication rates.
Design and application of hybrid maxillomandibular fixation for facial bone fractures.
Park, Kang-Nam; Oh, Seung-Min; Lee, Chang-Youn; Kim, Jwa-Young; Yang, Byoung-Eun
2013-01-01
A novel maxillomandibular fixation (MMF) procedure using a skeletal anchorage screw (SAS) (in the maxilla) and an arch bar (in the mandible), which we call "hybrid maxillomandibular fixation," was explored in this study. The aims of the study were to examine the efficacy of our hybrid MMF method and to compare periodontal tissue health and occlusal rehabilitation among 3 MMF methods. In total, 112 patients who had undergone open reduction at the Department of Oral and Maxillofacial Surgery between September 2005 and December 2012 were selected for this study. The participants were assigned to one of the following groups: SAS (maxilla), SAS (mandible), SAS-arch bar, or arch bar-arch bar. Periodontal health was evaluated using the Gingival Index, and the perioperative occlusal reproducibility was evaluated using a score of 1 to 3. Statistical analysis was performed using parametric tests (Student t test or 1-way analysis of variance followed by post hoc Tukey test). In the Gingival Index comparison performed 1 month after the surgery, only the group using the arch bars and wiring was significantly different from the other groups (P < 0.05). The occlusal reproducibility scores were not significantly different. The pain and discomfort of the patients were reduced in the hybrid MMF group. The hybrid MMF takes advantage of MMF using both arch bars and SASs for mandibular fractures. In addition, it overcomes many problems presented by previous MMF methods.
A new index to assess chemicals increasing the greenhouse effect based on their toxicity to algae.
Wang, Ting; Zhang, Xiaoxian; Tian, Dayong; Gao, Ya; Lin, Zhifen; Liu, Ying; Kong, Lingyun
2015-11-01
CO2, as the typical greenhouse gas causing the greenhouse effect, is a major global environmental problem and has attracted increasing attention from governments. Using algae to eliminate CO2, which has been proposed as an effective way to reduce the greenhouse effect in the past decades, can be disturbed by a growing number of artificial chemicals. Thus, seven types of chemicals and Selenastrum capricornutum (algae) were examined in this study, and the good consistency between the toxicity of artificial chemicals to algae and the disturbance of carbon fixation by the chemicals was revealed. This consistency showed that the disturbance of an increasing number of artificial chemicals to the carbon fixation of algae might be a "malware" worsening the global greenhouse effect. Therefore, this study proposes an original, promising index to assess the risk of deepening the greenhouse effect by artificial chemicals before they are produced and marketed. Copyright © 2015 Elsevier B.V. All rights reserved.
Kalivradzhiyan, E S; Podoprigora, A V; Kaverina, E Yu; Bobeshko, M N
The paper summarizes data on laboratory and clinical assessment of Corega denture adhesive cream adhesive properties: adhesion strength and time of adhesive material fixing. Clinical assessment was based on Ulitovsky-Leontyev denture fixation index evaluated in 18 edentulous patients with full removable dentures 1 and 12 months after denture manufacturing. After one year of evaluation denture fixation in patients using Corega denture adhesive cream was 8-15% better (depending on alveolar bed anatomy) than in controls proving that Corega improves full denture adaptation to physiological atrophy of alveolar bone.
Statistical dependency in visual scanning
NASA Technical Reports Server (NTRS)
Ellis, Stephen R.; Stark, Lawrence
1986-01-01
A method to identify statistical dependencies in the positions of eye fixations is developed and applied to eye movement data from subjects who viewed dynamic displays of air traffic and judged future relative position of aircraft. Analysis of approximately 23,000 fixations on points of interest on the display identified statistical dependencies in scanning that were independent of the physical placement of the points of interest. Identification of these dependencies is inconsistent with random-sampling-based theories used to model visual search and information seeking.
A technique for correction of equinus contracture using a wire fixator and elastic tension.
Melvin, J Stuart; Dahners, Laurence E
2006-02-01
Equinus contracture often is a complication of trauma, burns, or neurologic deficit. Many patients with contractures secondary to trauma or burns have poor soft tissue, which makes invasive correction a less appealing option. The Ilizarov external fixator has been used as a less invasive attempt to correct equinus contracture. We describe our "dynamic" technique and present a clinical patient series using a variation of the unconstrained Ilizarov technique, which uses elastic bands rather than threaded rods to supply the corrective force.
The eye-voice span during reading aloud
Laubrock, Jochen; Kliegl, Reinhold
2015-01-01
Although eye movements during reading are modulated by cognitive processing demands, they also reflect visual sampling of the input, and possibly preparation of output for speech or the inner voice. By simultaneously recording eye movements and the voice during reading aloud, we obtained an output measure that constrains the length of time spent on cognitive processing. Here we investigate the dynamics of the eye-voice span (EVS), the distance between eye and voice. We show that the EVS is regulated immediately during fixation of a word by either increasing fixation duration or programming a regressive eye movement against the reading direction. EVS size at the beginning of a fixation was positively correlated with the likelihood of regressions and refixations. Regression probability was further increased if the EVS was still large at the end of a fixation: if adjustment of fixation duration did not sufficiently reduce the EVS during a fixation, then a regression rather than a refixation followed with high probability. We further show that the EVS can help understand cognitive influences on fixation duration during reading: in mixed model analyses, the EVS was a stronger predictor of fixation durations than either word frequency or word length. The EVS modulated the influence of several other predictors on single fixation durations (SFDs). For example, word-N frequency effects were larger with a large EVS, especially when word N-1 frequency was low. Finally, a comparison of SFDs during oral and silent reading showed that reading is governed by similar principles in both reading modes, although EVS maintenance and articulatory processing also cause some differences. In summary, the EVS is regulated by adjusting fixation duration and/or by programming a regressive eye movement when the EVS gets too large. Overall, the EVS appears to be directly related to updating of the working memory buffer during reading. PMID:26441800
Corbett, Timothy J; Callanan, Anthony; O'Donnell, Michael R; McGloughlin, Tim M
2010-02-01
To develop an improved methodology for investigating the parameters influencing stent-graft migration, with particular focus on the limitations of existing methods. A physiological silicone rubber abdominal aortic aneurysm (AAA) model for fixation studies was manufactured based on an idealized AAA geometry: the model had a 24-mm neck, a 50-mm aneurysm, 12-mm-diameter legs, a 60 degrees bifurcation angle, and 2-mm-thick walls. The models were authenticated in neck fixation experiments. The displacement force required to migrate stent-grafts in physiological pulsatile flow was tested dynamically in water at 37 degrees C. A commercially available longitudinally rigid stent-graft (AneuRx) and a homemade device with little longitudinal rigidity were studied in a number of different configurations to investigate the effect of neck fixation length and systolic pressure on displacement force. The AneuRx (6.95+/-0.49 to 8.52+/-0.5 N) performed significantly better than the homemade device (2.57+/-0.11 to 4.62+/-0.25 N) in pulsatile flow. The opposite was true in the neck fixation tests because the longitudinal stiffness of the AneuRx was not accounted for. Increasing pressure or decreasing fixation length compromised the fixation of the homemade device. This relationship was not as clear for the AneuRx because decreasing proximal fixation resulted in an increase in iliac fixation, which could assist fixation in this device. Assessing the migration resistance of stent-grafts based solely on proximal fixation discriminates against devices that are longitudinally stiff. Current in vivo models may give inaccurate displacement forces due to the high degree of oversizing in these studies. A novel in vitro approach, accounting for longitudinal rigidity and realistic graft oversizing, was developed to determine the resistance of aortic stent-grafts to migration in the period immediately after device implantation.
NASA Astrophysics Data System (ADS)
Zhang, Jianlei; Weissing, Franz J.; Cao, Ming
2016-09-01
A commonly used assumption in evolutionary game theory is that natural selection acts on individuals in the same time scale; e.g., players use the same frequency to update their strategies. Variation in learning rates within populations suggests that evolutionary game theory may not necessarily be restricted to uniform time scales associated with the game interaction and strategy adaption evolution. In this study, we remove this restricting assumption by dividing the population into fast and slow groups according to the players' strategy updating frequencies and investigate how different strategy compositions of one group influence the evolutionary outcome of the other's fixation probabilities of strategies within its own group. Analytical analysis and numerical calculations are performed to study the evolutionary dynamics of strategies in typical classes of two-player games (prisoner's dilemma game, snowdrift game, and stag-hunt game). The introduction of the heterogeneity in strategy-update time scales leads to substantial changes in the evolution dynamics of strategies. We provide an approximation formula for the fixation probability of mutant types in finite populations and study the outcome of strategy evolution under the weak selection. We find that although heterogeneity in time scales makes the collective evolutionary dynamics more complicated, the possible long-run evolutionary outcome can be effectively predicted under technical assumptions when knowing the population composition and payoff parameters.
Gaze3DFix: Detecting 3D fixations with an ellipsoidal bounding volume.
Weber, Sascha; Schubert, Rebekka S; Vogt, Stefan; Velichkovsky, Boris M; Pannasch, Sebastian
2017-10-26
Nowadays, the use of eyetracking to determine 2-D gaze positions is common practice, and several approaches to the detection of 2-D fixations exist, but ready-to-use algorithms to determine eye movements in three dimensions are still missing. Here we present a dispersion-based algorithm with an ellipsoidal bounding volume that estimates 3D fixations. Therefore, 3D gaze points are obtained using a vector-based approach and are further processed with our algorithm. To evaluate the accuracy of our method, we performed experimental studies with real and virtual stimuli. We obtained good congruence between stimulus position and both the 3D gaze points and the 3D fixation locations within the tested range of 200-600 mm. The mean deviation of the 3D fixations from the stimulus positions was 17 mm for the real as well as for the virtual stimuli, with larger variances at increasing stimulus distances. The described algorithms are implemented in two dynamic linked libraries (Gaze3D.dll and Fixation3D.dll), and we provide a graphical user interface (Gaze3DFixGUI.exe) that is designed for importing 2-D binocular eyetracking data and calculating both 3D gaze points and 3D fixations using the libraries. The Gaze3DFix toolkit, including both libraries and the graphical user interface, is available as open-source software at https://github.com/applied-cognition-research/Gaze3DFix .
Song, Myung Gyu; Seo, Tae-Seok; Kim, Yun Hwan; Cho, Sung Bum; Jung, Euichul; Chung, Hwan Hoon; Lee, Seung Hwa
2016-07-12
To evaluate effectiveness of breast fixation to reduce migration of the catheter tip of a totally implantable venous access port (TIVP) in women. TIVPs were placed in 129 women via the right axillary vein from July 2012 to December 2014, with a final study population of 118 patients (mean age, 55.3 ± 13.8 years; range, 21-91 years). The patients were divided into two groups according to breast fixation during TIVP placement. A total of 56 patients received TIVP placement without breast fixation (Group 1); the remaining 62 received TIVP placement in the supine position after fixation of the ipsilateral breast on the abdominal wall in the sitting position (Group 2). Medical records were retrospectively reviewed for age, weight, height, body mass index, and underlying malignancy. We evaluated the difference in distance ratios between the port chamber and the catheter tip on supine chest and erect chest radiographs, respectively. Statistical analysis was performed using Student's t test. Differences in all parameters between Group 1 and Group 2 were not statistically significant. Mean distance ratio between the port chamber and the catheter tip was 1.95 ± 0.97 in Group 1 and 1.33 ± 0.59 in Group 2. Differences in distance ratios between the port chamber and the catheter tip were statistically significant between Group 1 and Group 2 (p = 0.001). Breast fixation seems to be effective in reducing migration of the port chamber and catheter tip with position changes in female patients during TIVP placement.
Fixation to features and neural processing of facial expressions in a gender discrimination task
Neath, Karly N.; Itier, Roxane J.
2017-01-01
Early face encoding, as reflected by the N170 ERP component, is sensitive to fixation to the eyes. Whether this sensitivity varies with facial expressions of emotion and can also be seen on other ERP components such as P1 and EPN, was investigated. Using eye-tracking to manipulate fixation on facial features, we found the N170 to be the only eye-sensitive component and this was true for fearful, happy and neutral faces. A different effect of fixation to features was seen for the earlier P1 that likely reflected general sensitivity to face position. An early effect of emotion (~120 ms) for happy faces was seen at occipital sites and was sustained until ~350 ms post-stimulus. For fearful faces, an early effect was seen around 80 ms followed by a later effect appearing at ~150 ms until ~300 ms at lateral posterior sites. Results suggests that in this emotion-irrelevant gender discrimination task, processing of fearful and happy expressions occurred early and largely independently of the eye-sensitivity indexed by the N170. Processing of the two emotions involved different underlying brain networks active at different times. PMID:26277653
Risk of population extinction from fixation of deleterious and reverse mutations.
Lande, R
1998-01-01
A model is developed for alternate fixations of mildly deleterious and wild-type alleles arising by forward and reverse mutation in a finite population. For almost all parameter values, this gives an equilibrium load that agrees closely with the general expression derived from diffusion theory. Nearly neutral mutations with selection coefficient a few times larger than 1/(2N(e)) do the most damage by increasing the equilibrium load. The model of alternate fixations facilitates dynamical analysis of the expected load and the mean time to extinction in a population that has been suddenly reduced from a very large size to a small size. Reverse mutation can substantially improve population viability, increasing the mean time to extinction by an order of magnitude or more, but because many mutations are irreversible the effects may not be large. Populations with initially high mean fitness and small effective size, N(e) below a few hundred individuals, may be at serious risk of extinction from fixation of deleterious mutations within 10(3) to 10(4) generations.
Shen, Xiaolong; Wang, Lei; Zhang, Hailong; Gu, Xin; Gu, Guangfei; He, Shisheng
2016-02-01
A prospective randomized study was conducted. The purpose of this study was to assess the radiographic outcomes of one-level minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) with unilateral pedicle screw instrumentation for degenerative lumbar spine disease. MI-TLIF has become an increasingly popular method of lumbar arthrodesis. Recent technological advances in spinal instrumentation have culminated in the development of MI-TLIF with unilateral pedicle screw fixation. However, there are few published studies on radiographic outcomes of the MI-TLIF with unilateral pedicle screw fixation. A total of 65 patients with one-level degenerative lumbar spine disease were enrolled in this study. Patients were randomized into the unilateral or bilateral fixation group based on a computer-generated number list. Thirty-one patients (17 men and 14 women; average age, 57.3 y) were randomized to the unilateral group (group A) and 34 patients (16 men and 18 women; average age, 58.9 y) to the bilateral group (group B). All patients underwent minimally invasive decompression, interbody fusion, and pedicle screw fixation with the assistance of microscopic tubular retractor system (METRx-MD) and Sextant system. All patients were asked to follow-up at 3, 6, and thereafter once every 6 months after surgery. The visual analog scale (VAS), Oswestry disability index (ODI), and modified Prolo (mProlo) scores were obtained for all patients 24 hours before the operation and at each follow-up visit. The whole lumbar lordosis (WL), the segmental lordosis (SL), fusion level disk space angle, lumbar scoliosis angle, and segmental scoliosis angle were determined before and after surgery on standard x-rays. The disk height index (DI) and the lumber curvature index (LI) were also evaluated. The mean follow-up was 26.6 months, with a range of 18-36 months. All patients showed evidence of fusion at 12 months postoperatively. Statistically, there was no significant difference between the 2 groups in terms of demographic data. The average postoperative VAS, ODI, and mProlo scores improved significantly in each group. No significant differences were found between the 2 groups in relation to VAS, ODI, and mProlo scores at each follow-up time point. There were no significant differences between the 2 groups in relation to WL, SL, disk space angle, lumbar scoliosis angle, segmental scoliosis angle, DI, and LI. There was also no difference between postoperative different follow-up visits in terms of these radiographic parameters in both groups. There was a positive linear correlation between the LI and WL in both groups. One-level unilateral pedicle screw instrumented MI-TLIF provided similar radiologic and clinical outcomes to bilateral pedicle screw instrumented MI-TLIF. This study showed that MIS-TLIF with unilateral pedicle screw fixation would be sufficient in the management of preoperatively stable patients with lumbar degenerative disease.
Insect-mediated nitrogen dynamics in decomposing wood
Michael D. Ulyshen
2015-01-01
1.Wood decomposition is characterised by complex and poorly understood nitrogen (N) dynamics with unclear implications for forest nutrient cycling and productivity.Wood-dwelling microbes have developed unique strategies for coping with the N limitations imposed by their substrate, including the translocation of N into wood by cord-forming fungi and the fixation of...
Gaze Dynamics in the Recognition of Facial Expressions of Emotion.
Barabanschikov, Vladimir A
2015-01-01
We studied preferably fixated parts and features of human face in the process of recognition of facial expressions of emotion. Photographs of facial expressions were used. Participants were to categorize these as basic emotions; during this process, eye movements were registered. It was found that variation in the intensity of an expression is mirrored in accuracy of emotion recognition; it was also reflected by several indices of oculomotor function: duration of inspection of certain areas of the face, its upper and bottom or right parts, right and left sides; location, number and duration of fixations, viewing trajectory. In particular, for low-intensity expressions, right side of the face was found to be attended predominantly (right-side dominance); the right-side dominance effect, was, however, absent for expressions of high intensity. For both low- and high-intensity expressions, upper face part was predominantly fixated, though with greater fixation of high-intensity expressions. The majority of trials (70%), in line with findings in previous studies, revealed a V-shaped pattern of inspection trajectory. No relationship, between accuracy of recognition of emotional expressions, was found, though, with either location and duration of fixations or pattern of gaze directedness in the face. © The Author(s) 2015.
Comparative Study of Intramedullary Hammertoe Fixation.
Obrador, Caterina; Losa-Iglesias, Marta; Becerro-de-Bengoa-Vallejo, Ricardo; Kabbash, Christina A
2018-04-01
Temporary Kirschner wire fixation (K-wire) is a widely used, low-cost fixation method for the correction of hammertoe deformity. Reported complications associated with K-wires prompted the development of new implants over the past decade. However, there is a lack of literature on comparative studies analyzing functional outcomes using validated questionnaires. The purpose of this study was to analyze functional outcomes in patients who had undergone proximal interphalangeal joint fusion using 2 types of intramedullary implant, the Smart Toe and the TenFuse, and to compare them with the outcomes in patients treated with standard K-wire fixation. A retrospective review of operative hammertoe correction by a single surgeon was performed in 96 patients followed for more than 12 months. Functional outcome was assessed using the Foot Function Index (FFI), the Short Form 36 (SF-36), and the 10-point visual analog scale (VAS) validated questionnaires. Complications and fusion rates were also evaluated. Several patients in the study underwent corrections in different toes; thus, a total of 186 toes were included in the study. From these, 65 toes (34.9%) were treated with K-wire fixation, 94 (50.5%) with Smart Toe titanium implant, and 27 (14.5%) with TenFuse allograft implant. No statistically significant differences in functional outcome and incidence of complications were observed among the 3 fixation groups, although the 2 intramedullary implants were associated with greater fusion rates and patient satisfaction. Breakage of the Smart Toe implant was significantly higher than that of the other fixations, with 10.6% of implants breaking within the first year postoperatively. SF-36 and VAS scores decreased 12 months after surgery for the 3 types of fixation, with no statistically significant differences observed. The use of Smart Toe and TenFuse implants provided operative outcomes comparable to those obtained using a K-wire fixation and slightly better patient satisfaction. Our results suggest that utilization of these implants for hammertoe correction was a reasonable choice that provided good alignment, pain reduction, and improved function at final follow-up. However, they are more expensive than K-wires. For this reason, in-depth cost-benefit studies would be required to justify their use as a standard treatment. Level III, comparative series.
Diversity and Activity of Diazotrophs in Great Barrier Reef Surface Waters.
Messer, Lauren F; Brown, Mark V; Furnas, Miles J; Carney, Richard L; McKinnon, A D; Seymour, Justin R
2017-01-01
Discrepancies between bioavailable nitrogen (N) concentrations and phytoplankton growth rates in the oligotrophic waters of the Great Barrier Reef (GBR) suggest that undetermined N sources must play a significant role in supporting primary productivity. One such source could be biological dinitrogen (N 2 ) fixation through the activity of "diazotrophic" bacterioplankton. Here, we investigated N 2 fixation and diazotroph community composition over 10° S of latitude within GBR surface waters. Qualitative N 2 fixation rates were found to be variable across the GBR but were relatively high in coastal, inner and outer GBR waters, reaching 68 nmol L -1 d -1 . Diazotroph assemblages, identified by amplicon sequencing of the nifH gene, were dominated by the cyanobacterium Trichodesmium erythraeum , γ-proteobacteria from the Gamma A clade, and δ-proteobacterial phylotypes related to sulfate-reducing genera. However, diazotroph communities exhibited significant spatial heterogeneity, correlated with shifts in dissolved inorganic nutrient concentrations. Specifically, heterotrophic diazotrophs generally increased in relative abundance with increasing concentrations of phosphate and N, while Trichodesmium was proportionally more abundant when concentrations of these nutrients were low. This study provides the first in-depth characterization of diazotroph community composition and N 2 fixation dynamics within the oligotrophic, N-limited surface waters of the GBR. Our observations highlight the need to re-evaluate N cycling dynamics within oligotrophic coral reef systems, to include diverse N 2 fixing assemblages as a potentially significant source of dissolved N within the water column.
Housman, D.C.; Powers, H.H.; Collins, A.D.; Belnap, J.
2006-01-01
Biological soil crusts (cyanobacteria, mosses and lichens collectively) perform essential ecosystem services, including carbon (C) and nitrogen (N) fixation. Climate and land-use change are converting later successional soil crusts to early successional soil crusts with lower C and N fixation rates. To quantify the effect of such conversions on C and N dynamics in desert ecosystems we seasonally measured diurnal fixation rates in different biological soil crusts. We classified plots on the Colorado Plateau (Canyonlands) and Chihuahuan Desert (Jornada) as early (Microcoleus) or later successional (Nostoc/Scytonema or Placidium/Collema) and measured photosynthesis (Pn), nitrogenase activity (NA), and chlorophyll fluorescence (Fv/Fm) on metabolically active (moist) soil crusts. Later successional crusts typically had greater Pn, averaging 1.2-1.3-fold higher daily C fixation in Canyonlands and 2.4-2.8-fold higher in the Jornada. Later successional crusts also had greater NA, averaging 1.3-7.5-fold higher daily N fixation in Canyonlands and 1.3-25.0-fold higher in the Jornada. Mean daily Fv/Fm was also greater in later successional Canyonlands crusts during winter, and Jornada crusts during all seasons except summer. Together these findings indicate conversion of soil crusts back to early successional stages results in large reductions of C and N inputs into these ecosystems.
A unique physeal injury of the distal phalanx.
Berber, Onur; Singh, Bijayendra
2015-01-01
An unusual Salter-Harris Type 1 fracture variant of the distal phalanx of the index finger is described. The epiphysis was dislocated, sitting dorsally over the middle phalanx head with the articular surface facing dorsal. Reduction could only be achieved through an open procedure. The reduction was stable without supplemental fixation.
Lorbach, Olaf; Zumbansen, Nikolaus; Kieb, Matthias; Efe, Turgay; Pizanis, Antonius; Kohn, Dieter; Haupert, Alexander
2018-04-01
Objective evaluation of the optimal graft tension angle to fully restore patellofemoral contact pressure in reconstruction of the medial patellofemoral ligament (MPFL) in comparison to the native knee. Twelve cadaveric knee specimens were fixed in a custom-made fixation device. A sensitive pressure film (Tekscan) was fixed in the patellofemoral joint, and patellofemoral contact pressure was assessed during a dynamic flexion movement from 0° to 90°. The MPFL was cut and measurements were repeated. Reconstruction of the MPFL was performed with the gracilis tendon subsequently fixed in the femur at 15°, 30°, 45°, 60°, 75°, and 90° of knee flexion under controlled tension (2 N). The sequence of the flexion angles was alternated. Pressure measurements were repeated after every fixation of the graft. No significant differences were seen in the overall patellofemoral contact pressure compared to the native knee (P > .05). However, medial patellofemoral pressure showed a significant increased patellofemoral contact pressure after MPFL reconstruction at a knee flexion angle during graft fixation of 15° (P = .027), 45° (P = .050, P = .044), and 75° (P = .039). Moreover, proximal/distal patellofemoral contact pressure revealed a significantly reduced contact pressure at 15° (P = .003), 30° (P = .009), 45° (P = .025), 75° (P = .021), and 90° (P = .022) of flexion distal after MPFL reconstruction compared with the intact knee. Lateral patellofemoral contact pressure was significantly reduced in all performed reconstructions (P < .05). The flexion angle during graft fixation for MPFL reconstruction did not have a significant impact on the overall patellofemoral contact pressure. However, selective medial, proximal, distal, and lateral patellofemoral contact pressure was significantly altered for all reconstructions. Fixation of the MPFL graft at 60° of flexion was able to most closely restore patellofemoral contact pressure compared with the intact knee. Based on the findings of the present study, fixation of the graft in anatomic reconstruction of the MPFL should be considered in 60° of flexion under low tension (2 N) to most closely restore patellofemoral contact pressure compared with the native knee. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Atmospheric dynamics in Laboratory Biosphere with wheat and sweet potato crops
NASA Astrophysics Data System (ADS)
Dempster, W. F.; Allen, J. P.; Alling, A.; Nelson, M.; Silvertone, S.; van Thillo, M.
Laboratory Biosphere is a 40 m3 closed life system equipped with 12000 watts of high pressure sodium lamps over planting beds with 5.37 m2 of soil. Atmospheric composition changes due to photosynthetic fixation of carbon dioxide and corresponding production of oxygen or the reverse, respiration, are observed in short timeframes, eg. hourly. To focus on inherent characteristics of the crop as distinct from its area or the volume of the chamber, we report fixation and respiration rates in millimoles per hour per square meter of planted area. An 85 day crop of USU Apogee wheat under a 16 hour lighted / 8 hour dark regime peaked in fixation rate at about 100 mmol h-1 m-2 approximately 24 days after planting. Light intensity was about 840 mol m-2 s-1. Dark respiration peaked at about 31 mmol h-1 m-2 at the same time. Thereafter, both fixation and respiration declined toward zero as harvest time approached. A residual soil respiration rate of about 1.9 mmol h-1 m-2 was observed in the dark closed chamber for 100 days after the harvest. A 126 day crop of Tuskegee TU-82-155 sweet potato behaved quite differently. Under a 680 mol m-2 s-1, 18 hour lighted / 6 hour dark regime, fixation during lighted hours rose to a plateau ranging from about 27 to 48 mmol h-1 m-2 after 42 days and respiration settled into a range of 12 to 23 mmol h-1 m-2. These rates continued unabated until the harvest at 126 days, suggesting that tuber biomass production might have continued at about the same rate for some time beyond the harvest time that was exercised in this experiment. In both experiments CO2 levels were allowed to range widely from a few hundred ppm to about 3000 ppm, which permitted observation of fixation rates both at varying CO2 concentrations and at each number of days after planting. This enables plotting the fixation rate as a function of both variables. Understanding the atmospheric dynamics of individual crops will be essential for design and atmospheric management of more complex CES which integrate the simultaneous growth of several crops as in a sustainable remote life support system.
Atmospheric dynamics in the “Laboratory Biosphere” with wheat and sweet potato crops
NASA Astrophysics Data System (ADS)
Dempster, William F.; Allen, J. P.; Alling, A.; Silverstone, S.; Van Thillo, M.
Laboratory Biosphere is a 40-m 3 closed life system equipped with 12,000 W of high pressure sodium lamps over planting beds with 5.37 m 2 of soil. Atmospheric composition changes due to photosynthetic fixation of carbon dioxide and corresponding production of oxygen or the reverse, respiration, are observed in short timeframes, e.g., hourly. To focus on inherent characteristics of the crop as distinct from its area or the volume of the chamber, we report fixation and respiration rates in mmol h -1 m -2 of planted area. An 85-day crop of USU Apogee wheat under a 16-h lighted/8-h dark regime peaked in fixation rate at about 100 mmol h -1 m -2 approximately 24 days after planting. Light intensity was about 840 μmol m -2 s -1. Dark respiration peaked at about 31 mmol h -1 m -2 at the same time. Thereafter, both fixation and respiration declined toward zero as harvest time approached. A residual soil respiration rate of about 1.9 mmol h -1 m -2 was observed in the dark closed chamber for 100 days after the harvest. A 126-day crop of Tuskegee TU-82-155 sweet potato behaved quite differently. Under a 680 μmol m -2 s -1, 18-h lighted/6-h dark regime, fixation during lighted hours rose to a plateau ranging from about 27 to 48 mmol h -1 m -2 after 42 days and dark respiration settled into a range of 12-23 mmol h -1 m -2. These rates continued unabated until the harvest at 126 days, suggesting that tuber biomass production might have continued at about the same rate for some time beyond the harvest time that was exercised in this experiment. In both experiments CO 2 levels were allowed to range widely from a few hundred to about 3000 ppm, which permitted observation of fixation rates both at varying CO 2 concentrations and at each number of days after planting. This enables plotting the fixation rate as a function of both variables. Understanding the atmospheric dynamics of individual crops will be essential for design and atmospheric management of more complex CELSS which integrate the simultaneous growth of several crops as in a sustainable remote life support system.
Effect of dynamic hip screw on the treatment of femoral neck fracture in the elderly.
Zhao, Wernbo; Liu, Lei; Zhang, Hui; Fang, Yue; Pei, Fuxing; Yang, Tianfu
2014-04-01
To discuss the indications, surgical procedures, and curative effect of dynamic hip screw (DHS) in the treatment of femoral neck fracture in the elderly. A retrospective study was conducted to analyse the clinical data of 42 elderly patients who had been treated for femoral neck fracture with DHS in our department between June 2009 and November 2011. There were 21 males and 21 females with a mean age of 68.5 years (range 60-75 years). According to the Garden Classification, there were 19 cases of type II, 21 cases of type III and 2 cases of type IV fractures. By the Singh Index Classification, there were 3 cases of level 2, 19 cases of level 3 and 20 cases of level 4 fractures. The Harris criterion, complications and function recovery after opera- tion were analysed. The average hospitalization time in 42 patients was 11.2 days (range 7-21 days). All patients were followed up for 12-26 months (mean 18 months). No lung infection, deep venous thrombosis or other complications occurred. Partial backing-out of the screws was found in 2 cases. The internal fixation device was withdrawn after fracture healing. Internal fixation cutting was found in 1 case, and he had a good recovery after total hip arthroplasty. The time for fracture healing ranged from 3-6 months (average 4.5 months). According to Harris criterion, 15 cases were rated as excellent, 24 good, 2 fair and 1 poor. The Harris scale was significantly improved from 30.52±2.71 preoperatively to 86.61±2.53 at 6 months postoperatively (P<0.05). DHS, being minimal invasive, allowing early activity and weight-bearing, is advisable for treatment of elderly patients with femoral neck fracture. In addition, it can avoid complications seen in artificial joint replacement. It is especially suitable for patients with mild osteoporosis.
Wenli, Zeng; Wuchao, Zhou; Jingkun, Zhang; Yisen, Shao; Weihong, Xi
2017-10-01
To explore the selection of temporomandibular joint (TMJ) disc reduction and fixation methods in condylar sagittal fracture surgery. A total of 36 patients with condylar fractures were chosen. The follow-up period was more 6 months. All 36 cases of condylar sagittal fracture were fixed with long screw. In the operation, the displaced joint disc was repositioned and fixed. The fixed method included direct suture (22 cases) and anchorage (14 cases). Clinical followups were performed before surgery and 1 month, 3 months, 6 months and 1 year after surgery. Clinicians recorded data related to the Fricton craniomandibular index (CMI) and evaluated the postoperative joint function during followup before surgery and 6 months after surgery. In both groups, function of TMJ significantly improved after surgery. The CMI decreased from 0.213±0.162 and 0.273±0.154 to 0.059±0.072 and 0.064±0.068 (P<0.05), respectively. No statistical difference was observed between the two groups in palpation index (PI), dysfunction index (DI) and CMI (P>0.05) before or after surgery. Both methods could effectively improve the dysfunction of the TMJ caused by trauma. The selection of joint disc reduction and fixation methods is based on the displacement and damage degree of the joint disc.
Stroud, Nicholas J; DiPaola, Matthew J; Martin, Brian L; Steiler, Cindy A; Flurin, Pierre-Henri; Wright, Thomas W; Zuckerman, Joseph D; Roche, Christopher P
2013-11-01
Numerous glenoid implant designs have been introduced into the global marketplace in recent years; however, little comparative biomechanical data exist to substantiate one design consideration over another. This study dynamically evaluated reverse shoulder glenoid baseplate fixation and compared the initial fixation associated with 2 reverse shoulder designs having an equivalent center of rotation in low-density and high-density bone substitute substrates. Significant differences in fixation were observed between implant designs, where the circular-porous reverse shoulder was associated with approximately twice the micromotion per equivalent test than the oblong-grit-blasted design. Additionally, 6 of the 7 circular-porous reverse shoulders failed catastrophically in the low-density bone model at an average of 2603 ± 981 cycles. None of the oblong-grit-blasted designs failed in the low-or high-density bone models and none of the circular-porous designs failed in the high-density bone models after 10,000 cycles of loading. These results demonstrate that significant differences in initial fixation exist between reverse shoulder implants having an equivalent center of rotation and suggest that design parameters, other than the position of the center of rotation, significantly affect fixation in low-density and high-density polyurethane bone substitutes. Subtle changes in glenoid baseplate design can dramatically affect fixation, particularly in low-density bone substitutes that are intended to simulate the bone quality of the recipient population for reverse shoulders. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Learning and Teaching Critical Thinking: From a Peircean Perspective
ERIC Educational Resources Information Center
Wells, Kelley
2009-01-01
The article will argue that Charles Sanders Peirce's concepts of the "Dynamics of Belief and Doubt", the "Fixation of Belief" as well as "habits of belief" taken together comprise a theory of learning. The "dynamics of belief and doubt" are Peirce's explanation for the process of changing from one belief to another. Teaching, then, would be an…
ERIC Educational Resources Information Center
Rice, Katherine; Moriuchi, Jennifer M.; Jones, Warren; Klin, Ami
2012-01-01
Objective: To examine patterns of variability in social visual engagement and their relationship to standardized measures of social disability in a heterogeneous sample of school-aged children with autism spectrum disorders (ASD). Method: Eye-tracking measures of visual fixation during free-viewing of dynamic social scenes were obtained for 109…
N2-fixation dynamics during ecosystem recovery in longleaf pine savannas
NASA Astrophysics Data System (ADS)
Tierney, J. A.
2016-12-01
Biological nitrogen fixation (BNF) can alleviate nitrogen (N) deficiencies that inhibit ecosystem recovery. BNF may be particularly important in ecosystems recovering from land-use change and perturbations from fire, as these disturbances can exacerbate N limitation. Here, we investigated how BNF dynamics change throughout ecosystem development in restored longleaf pine savannas, and how BNF responds to fire. We conducted this study in 59 1-ha plots of longleaf pine distributed across gradients of stand age and fire frequency at two sites in the southeastern US. We determined BNF contributions by three functional groups of N2-fixers (herbaceous legumes, biological soil crusts, and asymbiotic N2-fixing bacteria) by quantifying their abundances, assessing nitrogenase activity, and scaling these estimates up to the plot-level. To determine aboveground N demands, we measured tree growth using diameter increments and allometric equations paired with tissue-specific N concentrations. We fit linear models to evaluate the effects of stand age and time since fire on BNF and N demands throughout stand development, and performed separate analyses on mature stands to determine how fire return interval affects BNF. We observed distinct temporal patterns of N2-fixation across stand development among the three groups of N2 fixers. N2-fixation by legumes and asymbiotic bacteria remained low until stands reached maturity, while N2-fixation by biological soil crusts (BSCs) was high in juvenile stands and decreased with stand age. These patterns suggest a compensatory shift in the importance of these functional groups throughout stand development such that contributions from BSCs are critical for meeting N demands when disturbances may hinder the establishment of legumes and asymbiotic bacteria. N2-fixation by BSCs and asymbiotic bacteria throughout stand development was not affected by time since fire, but legume abundance increased the year following fire, suggesting a recovery mechanism provided by this group. Our findings suggest that BSCs are the most important source of new N in the early phases of ecosystem restoration. In contrast, legumes appear to be critical in mature longleaf pine stands that burn frequently, and particularly for supplying new N in the year following a fire event.
Improved OCT imaging of lung tissue using a prototype for total liquid ventilation
NASA Astrophysics Data System (ADS)
Schnabel, Christian; Meissner, Sven; Koch, Edmund
2011-06-01
Optical coherence tomography (OCT) is used for imaging subpleural alveoli in animal models to gain information about dynamic and morphological changes of lung tissue during mechanical ventilation. The quality of OCT images can be increased if the refraction index inside the alveoli is matched to the one of tissue via liquid-filling. Thereby, scattering loss can be decreased and higher penetration depth and tissue contrast can be achieved. Until now, images of liquid-filled lungs were acquired in isolated and fixated lungs only, so that an in vivo measurement situation is not present. To use the advantages of liquid-filling for in vivo imaging of small rodent lungs, it was necessary to develop a liquid ventilator. Perfluorodecalin, a perfluorocarbon, was selected as breathing fluid because of its refraction index being similar to the one of water and the high transport capacity for carbon dioxide and oxygen. The setup is characterized by two independent syringe pumps to insert and withdraw the fluid into and from the lung and a custom-made control program for volume- or pressure-controlled ventilation modes. The presented results demonstrate the liquid-filling verified by optical coherence tomography and intravital microscopy (IVM) and the advantages of liquid-filling to OCT imaging of subpleural alveoli.
Sutton, Nadia; MacDonald, Melinda H; Lombard, John; Ilie, Bodgan; Hinoul, Piet; Granger, Douglas A
2018-01-01
Aim To evaluate whether performing ventral hernia repairs using the Ethicon Physiomesh™ Open Flexible Composite Mesh Device in conjunction with the Ethicon Securestrap® Open Absorbable Strap Fixation Device reduces surgical time and surgeon stress levels, compared with traditional surgical repair methods. Methods To repair a simulated ventral incisional hernia, two surgeries were performed by eight experienced surgeons using a live porcine model. One procedure involved traditional suture methods and a flat mesh, and the other procedure involved a mechanical fixation device and a skirted flexible composite mesh. A Surgery Task Load Index questionnaire was administered before and after the procedure to establish the surgeons’ perceived stress levels, and saliva samples were collected before, during, and after the surgical procedures to assess the biologically expressed stress (cortisol and salivary alpha amylase) levels. Results For mechanical fixation using the Ethicon Physiomesh Open Flexible Composite Mesh Device in conjunction with the Ethicon Securestrap Open Absorbable Strap Fixation Device, surgeons reported a 46.2% reduction in perceived workload stress. There was also a lower physiological reactivity to the intraoperative experience and the total surgical procedure time was reduced by 60.3%. Conclusions This study provides preliminary findings suggesting that the combined use of a mechanical fixation device and a skirted flexible composite mesh in an open intraperitoneal onlay mesh repair has the potential to reduce surgeon stress. Additional studies are needed to determine whether a reduction in stress is observed in a clinical setting and, if so, confirm that this results in improved clinical outcomes. PMID:29296101
Salesky, Madeleine A; Grace, Trevor R; Feeley, Brian T; Ma, C Benjamin; Zhang, Alan L
2018-05-01
The influence of primary humeral stem fixation method (cemented or press fit) on intraoperative or postoperative outcomes in the setting of revision shoulder arthroplasty is unknown. A retrospective analysis of a prospectively collected cohort of revision shoulder arthroplasty patients from a single tertiary center was performed. Demographic variables, intraoperative data, and 90-day complication rates were compared between cemented and press-fit primary stem fixation cohorts. Follow-up radiographs were graded and compared using a modified Gruen system for humeral lucencies. Eighty-six primary shoulder replacements (34 hemiarthroplasties, 39 anatomic total shoulder arthroplasties, 13 reverse total shoulder arthroplasties) underwent revision arthroplasty with humeral stem removal between 2004 and 2017. Forty-five patients had cemented primary humeral fixation and 41 had press-fit fixation. The cemented cohort was older than the cementless cohort (66.6 vs. 61.4 years; P = .03) but otherwise demonstrated no difference in gender, body mass index, type of primary prosthesis (hemi, total, or reverse), or time between primary and revision operations. The cemented and cementless cohorts showed similar rates of humeral osteotomy (28.9% vs. 29.3%; P = .97), operative time (133.5 vs. 121.3 minutes; P = .16), and 90-day complication rates (13.3% vs. 9.8%; P = .61). Cemented vs. press-fit primary stems also had similar rates of humeral lucencies seen on follow-up radiographs after revision (77.1% vs. 60.6%; P = .14). Humeral stem fixation with or without cement during primary shoulder arthroplasty demonstrated similar operative time, need for intraoperative humeral osteotomy, and postoperative complication rates in the setting of revision arthroplasty. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Reconstruction with distraction osteogenesis for juxta-articular nonunions with bone loss.
Kabata, Tamon; Tsuchiya, Hiroyuki; Sakurakichi, Keisuke; Yamashiro, Teruhisa; Watanabe, Koji; Tomita, Kasuro
2005-06-01
Nonunions of a juxta-articular lesion with bone loss, which represent a challenging therapeutic problem, were treated using external fixation and distraction osteogenesis. Seven juxta-articular nonunions (five septic and two aseptic) were treated. The location of the nonunion was the distal femur in four patients, the proximal tibia in one patient, and the distal tibia in two patients. All of them were located within 5 cm from the affected joints. Preoperative limb shortening was present in six cases, averaging 2.9 cm (range, 1-7 cm). The reconstructive procedure consisted of refreshment of the nonunion site, deformity correction, stabilization by external fixation, and lengthening to eliminate leg length discrepancy or to fill the defect. Shortening-distraction was applied to six patients and bone transport to one patient for reconstruction. Intramedullary nailing to reduce the duration of external fixation was simultaneously performed in two cases. All the patients had at least 1 year of follow-up evaluation. Osseous union without angular deformity or leg length discrepancy greater than 1 cm was achieved in all patients. The mean amount of lengthening was 5.8 cm (range, 2.2-10.0 cm). The mean external fixation period was 219 days (range, 98-317 days), and the mean external fixation index was 34.4 days/cm (range, 24.5-47.6 days/cm). All patients reported excellent pain reduction. There were no recurrences of infection in five patients with prior history of osteomyelitis. The functional results were categorized as excellent in two, good in three, and fair in two. Despite the length of postoperative external fixation, distraction osteogenesis can be a valuable alternative for the treatment of juxta-articular nonunions.
Kaku, Nobuhiro; Tabata, Tomonori; Tsumura, Hiroshi
2015-12-01
We verified the index cup position required for bulk bone grafting instead of morcellized grafting immediately after cementless total hip arthroplasty. Three-dimensional finite element analysis was used to evaluate changes in the volume of the slippage of the cup-host bone interface as micro-motion of the cup at the acetabular bone defect site depending on the cup-center-edge (CE) angle. The conditions of bulk bone grafts were similar to those of cortical bone. Slippage increased with decreasing cup-CE angle. A bulk bone graft tightly fixed to the host bone prevented considerably larger slippage between the cup and host bone. A smaller cup-CE angle increased the impact of the bulk bone graft on slippage. When the cup-CE angle was 0° or -10°, the criterion for slippage in favorable initial fixation in all conditions was <40 μm. Even if transplanted bulk bone is used, unless good fixation is obtained between the host bone, and the cup and bone graft, it is impossible to obtain reliable fixation of the cup with a cup-CE angle <-10° and slippage exceeding 40 μm. Bulk bone grafting tightly fixed to the host bone improves initial the cup-host bone fixation, especially when the cup-CE angle is small, such as <-10°. In clinical practice, negative factors are implicated in the initial fixation of various cups, and sufficient fixation between the host bone and cup or bulk bone graft using a screw is effective when the cup-CE angle is extremely small.
Improvement in nitrogen fixation capacity could be part of the domestication process in soybean
Muñoz, N; Qi, X; Li, M-W; Xie, M; Gao, Y; Cheung, M-Y; Wong, F-L; Lam, H-M
2016-01-01
Biological nitrogen fixation (BNF) in soybeans is a complex process involving the interplay between the plant host and the symbiotic rhizobia. As nitrogen supply has a crucial role in growth and development, higher nitrogen fixation capacity would be important to achieve bigger plants and larger seeds, which were important selection criteria during plant domestication by humans. To test this hypothesis, we monitored the nitrogen fixation-related performance in 31 cultivated and 17 wild soybeans after inoculation with the slow-growing Bradyrhizobium diazoefficiens sp. nov. USDA110 and the fast-growing Sinorhizobium (Ensifer) fredii CCBAU45436. Our results showed that, in general, cultivated soybeans gave better performance in BNF. Electron microscopic studies indicated that there was an exceptionally high accumulation of poly-β-hydroxybutyrate bodies in bacteroids in the nodules of all wild soybeans tested, suggesting that the C/N balance in wild soybeans may not be optimized for nitrogen fixation. Furthermore, we identified new quantitative trait loci (QTLs) for total ureides and total nodule fresh weight by employing a recombinant inbred population composed of descendants from a cross between a cultivated and a wild parent. Using nucleotide diversity (θπ), divergence index (Fst) and distribution of fixed single-nucleotide polymorphisms as parameters, we found that some regions in the total ureides QTL on chromosome 17 and the total nodule fresh weight QTL on chromosome 12 exhibited very low diversity among cultivated soybeans, suggesting that these were traits specially selected during the domestication and breeding process. PMID:27118154
Finger, T; Bayerl, S; Bertog, M; Czabanka, M; Woitzik, J; Vajkoczy, P
2016-11-01
We hypothesised, that the inclusion of the ilium for multilevel lumbosacral fusions reduces the incidence of postoperative sacroiliac joint (SIJ) pain. The primary objective of this study was to compare the frequency of postoperative SIJ pain in patients undergoing multilevel stabilization with and without sacropelvic fixation for multilevel degenerative spine disease. In addition, we aimed at identifying factors that may predict the worsening or new onset of postoperative SIJ pain. A total of 63 patients with multisegmental fusion surgery with a minimum follow up of 12 months were evaluated. 34 patients received sacral fixation (SF group) and 29 patients received an additional sacropelvic fixation device (SPF group). Primary outcome parameters were changes in SIJ pain between the groups and the influence of pelvic parameters, the patient́s age, the patient́s body mass index (BMI) and the length of the stabilization on the SIJ pain. Between the two surgical groups there were no differences concerning age (p=0.3), BMI (p=0.56), length of follow up (p=0.96), length of the construct (p=0.56). In total 31.7% of the patients had a worsening/new onset of SIJ pain after surgery. An additional fixation of the SIJ with iliac screws or iliosacral plate did not have an influence on the SIJ pain (p=0.67). Likewise, pelvic parameters were not predictive for the outcome of the SIJ pain. Only an increased preoperative BMI correlated with a higher chance of a new onset of SIJ pain (p=0.037). In our retrospective study there was no influence of a sacropelvic fixation techniques on the SIJ pain in patients with multilevel degenerative spine disease after multilevel stabilization surgeries. The patients' BMI is the only preoperative factor that correlated with a higher incidence to develop postoperative SIJ pain, independently of the implantation of a sacropelvic fixation device. Copyright © 2016 Elsevier B.V. All rights reserved.
Sensorimotor recovery following spaceflight may be due to frequent square-wave saccadic intrusions
NASA Technical Reports Server (NTRS)
Reschke, Millard; Somers, Jeffrey T.; Leigh, R. John; Krnavek, Jody M.; Kornilova, Ludmila; Kozlovskaya, Inessa; Bloomberg, Jacob J.; Paloski, William H.
2004-01-01
Square-wave jerks (SWJs) are small, involuntary saccades that disrupt steady fixation. We report the case of an astronaut (approximately 140 d on orbit) who showed frequent SWJs, especially postflight, but who showed no impairment of vision or decrement of postflight performance. These data support the view that SWJs do not impair vision because they are paired movements, consisting of a small saccade away from the fixation position followed, within 200 ms, by a corrective saccade that brings the eye back on target. Since many returning astronauts show a decrement of dynamic visual function during postflight locomotion, it seems possible that frequent SWJs improved this astronaut's visual function by providing postsaccadic enhancement of visual fixation, which aided postflight performance. Certainly, frequent SWJs did not impair performance in this astronaut, who had no other neurological disorder.
Gundale, Michael J; Bach, Lisbet H; Nordin, Annika
2013-01-01
Bryophytes achieve substantial biomass and play several key functional roles in boreal forests that can influence how carbon (C) and nitrogen (N) cycling respond to atmospheric deposition of reactive nitrogen (Nr). They associate with cyanobacteria that fix atmospheric N₂, and downregulation of this process may offset anthropogenic Nr inputs to boreal systems. Bryophytes also promote soil C accumulation by thermally insulating soils, and changes in their biomass influence soil C dynamics. Using a unique large-scale (0.1 ha forested plots), long-term experiment (16 years) in northern Sweden where we simulated anthropogenic Nr deposition, we measured the biomass and N₂-fixation response of two bryophyte species, the feather mosses Hylocomium splendens and Pleurozium schreberi. Our data show that the biomass declined for both species; however, N₂-fixation rates per unit mass and per unit area declined only for H. splendens. The low and high treatments resulted in a 29% and 54% reduction in total feather moss biomass, and a 58% and 97% reduction in total N₂-fixation rate per unit area, respectively. These results help to quantify the sensitivity of feather moss biomass and N₂ fixation to chronic Nr deposition, which is relevant for modelling ecosystem C and N balances in boreal ecosystems.
A unique physeal injury of the distal phalanx
Berber, Onur; Singh, Bijayendra
2015-01-01
Abstract An unusual Salter–Harris Type 1 fracture variant of the distal phalanx of the index finger is described. The epiphysis was dislocated, sitting dorsally over the middle phalanx head with the articular surface facing dorsal. Reduction could only be achieved through an open procedure. The reduction was stable without supplemental fixation. PMID:27252957
Finding the Right Fit: A Comparison of Process Assumptions Underlying Popular Drift-Diffusion Models
ERIC Educational Resources Information Center
Ashby, Nathaniel J. S.; Jekel, Marc; Dickert, Stephan; Glöckner, Andreas
2016-01-01
Recent research makes increasing use of eye-tracking methodologies to generate and test process models. Overall, such research suggests that attention, generally indexed by fixations (gaze duration), plays a critical role in the construction of preference, although the methods used to support this supposition differ substantially. In two studies…
Biomechanical analysis of fixation of middle third fractures of the clavicle.
Drosdowech, Darren S; Manwell, Stuart E E; Ferreira, Louis M; Goel, Danny P; Faber, Kenneth J; Johnson, James A
2011-01-01
This biomechanical study compares four different techniques of fixation of middle third clavicular fractures. Twenty fresh-frozen clavicles were randomized into four groups. Each group used a different fixation device (3.5 Synthes reconstruction plate, 3.5 Synthes limited contact dynamic compression plate, 3.5 Synthes locking compression plate, and 4.5 DePuy Rockwood clavicular pin). All constructs were mechanically tested in bending and torque modes both with and without a simulated inferior cortical defect. Bending load to failure was also conducted. The four groups were compared using an analysis of variance test. The plate constructs were stiffer than the pin during both pure bending and torque loads with or without an inferior cortical defect. Bending load to failure with an inferior cortical defect revealed that the reconstruction plate was weaker compared with the other three groups. The limited contact and locking plates were stiffer than the reconstruction plate but demonstrated statistical significance only with the cortical defect. As hypothesized, the 3.5 limited contact dynamic compression plate and 3.5 locking compression plate demonstrated the greatest resistance to bending and torque loads, especially in the presence of simulated comminution of a middle third clavicular fracture. The reconstruction plate demonstrated lower stiffness and strength values compared with the other plates, especially with a cortical defect, whereas the pin showed poor resistance to bending and torque loads in all modes of testing. This information may help surgeons to choose the most appropriate method of fixation when treating fractures of the middle third of the clavicle.
Ammonia oxidation coupled to CO2 fixation by archaea and bacteria in an agricultural soil.
Pratscher, Jennifer; Dumont, Marc G; Conrad, Ralf
2011-03-08
Ammonia oxidation is an essential part of the global nitrogen cycling and was long thought to be driven only by bacteria. Recent findings expanded this pathway also to the archaea. However, most questions concerning the metabolism of ammonia-oxidizing archaea, such as ammonia oxidation and potential CO(2) fixation, remain open, especially for terrestrial environments. Here, we investigated the activity of ammonia-oxidizing archaea and bacteria in an agricultural soil by comparison of RNA- and DNA-stable isotope probing (SIP). RNA-SIP demonstrated a highly dynamic and diverse community involved in CO(2) fixation and carbon assimilation coupled to ammonia oxidation. DNA-SIP showed growth of the ammonia-oxidizing bacteria but not of archaea. Furthermore, the analysis of labeled RNA found transcripts of the archaeal acetyl-CoA/propionyl-CoA carboxylase (accA/pccB) to be expressed and labeled. These findings strongly suggest that ammonia-oxidizing archaeal groups in soil autotrophically fix CO(2) using the 3-hydroxypropionate-4-hydroxybutyrate cycle, one of the two pathways recently identified for CO(2) fixation in Crenarchaeota. Catalyzed reporter deposition (CARD)-FISH targeting the gene encoding subunit A of ammonia monooxygenase (amoA) mRNA and 16S rRNA of archaea also revealed ammonia-oxidizing archaea to be numerically relevant among the archaea in this soil. Our results demonstrate a diverse and dynamic contribution of ammonia-oxidizing archaea in soil to nitrification and CO(2) assimilation and that their importance to the overall archaeal community might be larger than previously thought.
Ammonia oxidation coupled to CO2 fixation by archaea and bacteria in an agricultural soil
Pratscher, Jennifer; Dumont, Marc G.; Conrad, Ralf
2011-01-01
Ammonia oxidation is an essential part of the global nitrogen cycling and was long thought to be driven only by bacteria. Recent findings expanded this pathway also to the archaea. However, most questions concerning the metabolism of ammonia-oxidizing archaea, such as ammonia oxidation and potential CO2 fixation, remain open, especially for terrestrial environments. Here, we investigated the activity of ammonia-oxidizing archaea and bacteria in an agricultural soil by comparison of RNA- and DNA-stable isotope probing (SIP). RNA-SIP demonstrated a highly dynamic and diverse community involved in CO2 fixation and carbon assimilation coupled to ammonia oxidation. DNA-SIP showed growth of the ammonia-oxidizing bacteria but not of archaea. Furthermore, the analysis of labeled RNA found transcripts of the archaeal acetyl-CoA/propionyl-CoA carboxylase (accA/pccB) to be expressed and labeled. These findings strongly suggest that ammonia-oxidizing archaeal groups in soil autotrophically fix CO2 using the 3-hydroxypropionate–4-hydroxybutyrate cycle, one of the two pathways recently identified for CO2 fixation in Crenarchaeota. Catalyzed reporter deposition (CARD)-FISH targeting the gene encoding subunit A of ammonia monooxygenase (amoA) mRNA and 16S rRNA of archaea also revealed ammonia-oxidizing archaea to be numerically relevant among the archaea in this soil. Our results demonstrate a diverse and dynamic contribution of ammonia-oxidizing archaea in soil to nitrification and CO2 assimilation and that their importance to the overall archaeal community might be larger than previously thought. PMID:21368116
Fixation to features and neural processing of facial expressions in a gender discrimination task.
Neath, Karly N; Itier, Roxane J
2015-10-01
Early face encoding, as reflected by the N170 ERP component, is sensitive to fixation to the eyes. Whether this sensitivity varies with facial expressions of emotion and can also be seen on other ERP components such as P1 and EPN, was investigated. Using eye-tracking to manipulate fixation on facial features, we found the N170 to be the only eye-sensitive component and this was true for fearful, happy and neutral faces. A different effect of fixation to features was seen for the earlier P1 that likely reflected general sensitivity to face position. An early effect of emotion (∼120 ms) for happy faces was seen at occipital sites and was sustained until ∼350 ms post-stimulus. For fearful faces, an early effect was seen around 80 ms followed by a later effect appearing at ∼150 ms until ∼300 ms at lateral posterior sites. Results suggests that in this emotion-irrelevant gender discrimination task, processing of fearful and happy expressions occurred early and largely independently of the eye-sensitivity indexed by the N170. Processing of the two emotions involved different underlying brain networks active at different times. Copyright © 2015 Elsevier Inc. All rights reserved.
Preference for Geometric Patterns Early in Life as a Risk Factor for Autism
Pierce, Karen; Conant, David; Hazin, Roxana; Stoner, Richard; Desmond, Jamie
2016-01-01
Context Early identification efforts are essential for the early treatment of the symptoms of autism but can only occur if robust risk factors are found. Children with autism often engage in repetitive behaviors and anecdotally prefer to visually examine geometric repetition, such as the moving blade of a fan or the spinning of a car wheel. The extent to which a preference for looking at geometric repetition is an early risk factor for autism has yet to be examined. Objectives To determine if toddlers with an autism spectrum disorder (ASD) aged 14 to 42 months prefer to visually examine dynamic geometric images more than social images and to determine if visual fixation patterns can correctly classify a toddler as having an ASD. Design Toddlers were presented with a 1-minute movie depicting moving geometric patterns on 1 side of a video monitor and children in high action, such as dancing or doing yoga, on the other. Using this preferential looking paradigm, total fixation duration and the number of saccades within each movie type were examined using eye tracking technology. Setting University of California, San Diego Autism Center of Excellence. Participants One hundred ten toddlers participated in final analyses (37 with an ASD, 22 with developmental delay, and 51 typical developing toddlers). Main Outcome Measure Total fixation time within the geometric patterns or social images and the number of saccades were compared between diagnostic groups. Results Overall, toddlers with an ASD as young as 14 months spent significantly more time fixating on dynamic geometric images than other diagnostic groups. If a toddler spent more than 69% of his or her time fixating on geometric patterns, then the positive predictive value for accurately classifying that toddler as having an ASD was 100%. Conclusion A preference for geometric patterns early in life may be a novel and easily detectable early signature of infants and toddlers at risk for autism. PMID:20819977
Cell fixation and preservation for droplet-based single-cell transcriptomics.
Alles, Jonathan; Karaiskos, Nikos; Praktiknjo, Samantha D; Grosswendt, Stefanie; Wahle, Philipp; Ruffault, Pierre-Louis; Ayoub, Salah; Schreyer, Luisa; Boltengagen, Anastasiya; Birchmeier, Carmen; Zinzen, Robert; Kocks, Christine; Rajewsky, Nikolaus
2017-05-19
Recent developments in droplet-based microfluidics allow the transcriptional profiling of thousands of individual cells in a quantitative, highly parallel and cost-effective way. A critical, often limiting step is the preparation of cells in an unperturbed state, not altered by stress or ageing. Other challenges are rare cells that need to be collected over several days or samples prepared at different times or locations. Here, we used chemical fixation to address these problems. Methanol fixation allowed us to stabilise and preserve dissociated cells for weeks without compromising single-cell RNA sequencing data. By using mixtures of fixed, cultured human and mouse cells, we first showed that individual transcriptomes could be confidently assigned to one of the two species. Single-cell gene expression from live and fixed samples correlated well with bulk mRNA-seq data. We then applied methanol fixation to transcriptionally profile primary cells from dissociated, complex tissues. Low RNA content cells from Drosophila embryos, as well as mouse hindbrain and cerebellum cells prepared by fluorescence-activated cell sorting, were successfully analysed after fixation, storage and single-cell droplet RNA-seq. We were able to identify diverse cell populations, including neuronal subtypes. As an additional resource, we provide 'dropbead', an R package for exploratory data analysis, visualization and filtering of Drop-seq data. We expect that the availability of a simple cell fixation method will open up many new opportunities in diverse biological contexts to analyse transcriptional dynamics at single-cell resolution.
Kornrumpf, Benthe; Dimigen, Olaf; Sommer, Werner
2017-06-01
Visuospatial attention is an important mechanism in reading that governs the uptake of information from foveal and parafoveal regions of the visual field. However, the spatiotemporal dynamics of how attention is allocated during eye fixations are not completely understood. The current study explored the use of EEG alpha-band oscillations to investigate the spatial distribution of attention during reading. We reanalyzed two data sets, focusing on the lateralization of alpha activity at posterior scalp sites. In each experiment, participants read short lists of German nouns in two paradigms: either by freely moving their eyes (saccadic reading) or by fixating the screen center while the text moved passively from right to left at the same average speed (RSVP paradigm). In both paradigms, upcoming words were either visible or masked, and foveal processing load was manipulated by varying the words' lexical frequencies. Posterior alpha lateralization revealed a sustained rightward bias of attention during saccadic reading, but not in the RSVP paradigm. Interestingly, alpha lateralization was not influenced by word frequency (foveal load) or preview during the preceding fixation. Hence, alpha did not reflect transient attention shifts within a given fixation. However, in both experiments, we found that in the saccadic reading condition a stronger alpha lateralization shortly before a saccade predicted shorter fixations on the subsequently fixated word. These results indicate that alpha lateralization can serve as a measure of attention deployment and its link to oculomotor behavior in reading. © 2017 Society for Psychophysiological Research.
Visual attention mechanisms in happiness versus trustworthiness processing of facial expressions.
Calvo, Manuel G; Krumhuber, Eva G; Fernández-Martín, Andrés
2018-03-01
A happy facial expression makes a person look (more) trustworthy. Do perceptions of happiness and trustworthiness rely on the same face regions and visual attention processes? In an eye-tracking study, eye movements and fixations were recorded while participants judged the un/happiness or the un/trustworthiness of dynamic facial expressions in which the eyes and/or the mouth unfolded from neutral to happy or vice versa. A smiling mouth and happy eyes enhanced perceived happiness and trustworthiness similarly, with a greater contribution of the smile relative to the eyes. This comparable judgement output for happiness and trustworthiness was reached through shared as well as distinct attentional mechanisms: (a) entry times and (b) initial fixation thresholds for each face region were equivalent for both judgements, thereby revealing the same attentional orienting in happiness and trustworthiness processing. However, (c) greater and (d) longer fixation density for the mouth region in the happiness task, and for the eye region in the trustworthiness task, demonstrated different selective attentional engagement. Relatedly, (e) mean fixation duration across face regions was longer in the trustworthiness task, thus showing increased attentional intensity or processing effort.
Zhang, Wei; Luo, Cong-Feng; Putnis, Sven; Sun, Hui; Zeng, Zhi-Min; Zeng, Bing-Fang
2012-03-01
The posterolateral shearing tibial plateau fracture is uncommon in the literature, however with the increased usage of computer tomography (CT), the incidence of these fractures is no longer as low as previously thought. Few studies have concentrated on this fracture, least of all using a biomechanical model. The purpose of this study was to compare and analyse the biomechanical characteristics of four different types of internal fixation to stabilise the posterolateral shearing tibial plateau fracture. Forty synthetic tibiae (Synbone, right) simulated the posterolateral shearing fracture models and these were randomly assigned into four groups; Group A was fixed with two anterolateral lag screws, Group B with an anteromedial Limited Contact Dynamic Compression Plate (LC-DCP), Group C with a lateral locking plate, and Group D with a posterolateral buttress plate. Vertical displacement of the posterolateral fragment was measured using three different strengths of axial loading force, and finally loaded until fixation failure. It was concluded that the posterolateral buttress plate is biomechanically the strongest fixation method for the posterolateral shearing tibial plateau fracture. Copyright © 2011 Elsevier B.V. All rights reserved.
Exact numerical calculation of fixation probability and time on graphs.
Hindersin, Laura; Möller, Marius; Traulsen, Arne; Bauer, Benedikt
2016-12-01
The Moran process on graphs is a popular model to study the dynamics of evolution in a spatially structured population. Exact analytical solutions for the fixation probability and time of a new mutant have been found for only a few classes of graphs so far. Simulations are time-expensive and many realizations are necessary, as the variance of the fixation times is high. We present an algorithm that numerically computes these quantities for arbitrary small graphs by an approach based on the transition matrix. The advantage over simulations is that the calculation has to be executed only once. Building the transition matrix is automated by our algorithm. This enables a fast and interactive study of different graph structures and their effect on fixation probability and time. We provide a fast implementation in C with this note (Hindersin et al., 2016). Our code is very flexible, as it can handle two different update mechanisms (Birth-death or death-Birth), as well as arbitrary directed or undirected graphs. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Enhanced bone screw fixation with biodegradable bone cement in osteoporotic bone model.
Juvonen, Tiina; Koistinen, Arto; Kröger, Heikki; Lappalainen, Reijo
2012-09-27
The purpose of this study was to study the potential of novel biodegradable PCL bone cement to improve bone screw fixation strength in osteoporotic bone. The biomechanical properties of bone cement (ε-polycaprolactone, PCL) and fixation strength were studied using biomechanical tests and bone screws fixed in an osteoporotic bone model. Removal torques and pullout strengths were assessed for cortical, self-tapping, and cancellous screws inserted in the osteoporotic bone model (polyurethane foam blocks with polycarbonate plate) with and without PCL bone cement. Open cell and cellular rigid foam blocks with a density of 0.12 g/cm3 were used in this model. Removal torques were significantly (more than six-fold) improved with bone cement for cancellous screws. Furthermore, the bone cement improved pullout strengths three to 12 times over depending on the screw and model material. Biodegradable bone cement turned out to be a very potential material to stabilize screw fixation in osteoporotic bone. The results warrant further research before safe clinical use, especially to clarify clinically relevant factors using real osteoporotic bone under human body conditions and dynamic fatigue testing for long-term performance.
Large fluctuations in anti-coordination games on scale-free graphs
NASA Astrophysics Data System (ADS)
Sabsovich, Daniel; Mobilia, Mauro; Assaf, Michael
2017-05-01
We study the influence of the complex topology of scale-free graphs on the dynamics of anti-coordination games (e.g. snowdrift games). These reference models are characterized by the coexistence (evolutionary stable mixed strategy) of two competing species, say ‘cooperators’ and ‘defectors’, and, in finite systems, by metastability and large-fluctuation-driven fixation. In this work, we use extensive computer simulations and an effective diffusion approximation (in the weak selection limit) to determine under which circumstances, depending on the individual-based update rules, the topology drastically affects the long-time behavior of anti-coordination games. In particular, we compute the variance of the number of cooperators in the metastable state and the mean fixation time when the dynamics is implemented according to the voter model (death-first/birth-second process) and the link dynamics (birth/death or death/birth at random). For the voter update rule, we show that the scale-free topology effectively renormalizes the population size and as a result the statistics of observables depend on the network’s degree distribution. In contrast, such a renormalization does not occur with the link dynamics update rule and we recover the same behavior as on complete graphs.
Designs and Algorithms to Map Eye Tracking Data with Dynamic Multielement Moving Objects.
Kang, Ziho; Mandal, Saptarshi; Crutchfield, Jerry; Millan, Angel; McClung, Sarah N
2016-01-01
Design concepts and algorithms were developed to address the eye tracking analysis issues that arise when (1) participants interrogate dynamic multielement objects that can overlap on the display and (2) visual angle error of the eye trackers is incapable of providing exact eye fixation coordinates. These issues were addressed by (1) developing dynamic areas of interests (AOIs) in the form of either convex or rectangular shapes to represent the moving and shape-changing multielement objects, (2) introducing the concept of AOI gap tolerance (AGT) that controls the size of the AOIs to address the overlapping and visual angle error issues, and (3) finding a near optimal AGT value. The approach was tested in the context of air traffic control (ATC) operations where air traffic controller specialists (ATCSs) interrogated multiple moving aircraft on a radar display to detect and control the aircraft for the purpose of maintaining safe and expeditious air transportation. In addition, we show how eye tracking analysis results can differ based on how we define dynamic AOIs to determine eye fixations on moving objects. The results serve as a framework to more accurately analyze eye tracking data and to better support the analysis of human performance.
Designs and Algorithms to Map Eye Tracking Data with Dynamic Multielement Moving Objects
Mandal, Saptarshi
2016-01-01
Design concepts and algorithms were developed to address the eye tracking analysis issues that arise when (1) participants interrogate dynamic multielement objects that can overlap on the display and (2) visual angle error of the eye trackers is incapable of providing exact eye fixation coordinates. These issues were addressed by (1) developing dynamic areas of interests (AOIs) in the form of either convex or rectangular shapes to represent the moving and shape-changing multielement objects, (2) introducing the concept of AOI gap tolerance (AGT) that controls the size of the AOIs to address the overlapping and visual angle error issues, and (3) finding a near optimal AGT value. The approach was tested in the context of air traffic control (ATC) operations where air traffic controller specialists (ATCSs) interrogated multiple moving aircraft on a radar display to detect and control the aircraft for the purpose of maintaining safe and expeditious air transportation. In addition, we show how eye tracking analysis results can differ based on how we define dynamic AOIs to determine eye fixations on moving objects. The results serve as a framework to more accurately analyze eye tracking data and to better support the analysis of human performance. PMID:27725830
Tibiotalocalcaneal arthrodesis using a dynamically locked retrograde intramedullary nail.
Pelton, Kevin; Hofer, Jason K; Thordarson, David B
2006-10-01
Tibiotalocalcaneal arthrodesis is an important salvage method for patients with complex hindfoot problems, including Charcot arthropathy, osteonecrosis of the talus, combined arthritis of the ankle and subtalar joint, and failed total ankle arthroplasty. This study evaluated the results of a dynamic retrograde intramedullary nail for fixation with posterior to anterior distal interlocking screws placed through the calcaneus for tibiotalocalcaneal fusion. Thirty-three consecutive tibiotalocalcaneal fusions were done by a single surgeon (DBT) and were stabilized with a dynamic retrograde intramedullary nail. Time to fusion, impaction of the nail relative to the intramedullary canal, nail-tibial angle, and complications were noted. Average followup was 14 months. Twenty-nine of 33 feet (88%) fused at an average of 3.7 months after surgery. Average impaction of the nail was 2.3 (0.5 to 5.0) mm. Cortical hypertrophy at the tip of the rod or at the proximal interlocking screw was noted in 13 of 27 patients. A trend toward a higher nonunion rate was noted in patients with an increased nail-tibial angle. Dynamic retrograde intramedullary nailing for fixation of the tibiotalocalcaneal fusions is a good method of stabilizing this complex fusion construct.
Forrester, David I; Schortemeyer, Marcus; Stock, William D; Bauhus, Jürgen; Khanna, Partap K; Cowie, Annette L
2007-09-01
Mixtures of Eucalyptus globulus Labill. and Acacia mearnsii de Wildeman are twice as productive as E. globulus monocultures growing on the same site in East Gippsland, Victoria, Australia, possibly because of increased nitrogen (N) availability owing to N(2) fixation by A. mearnsii. To investigate whether N(2) fixation by A. mearnsii could account for the mixed-species growth responses, we assessed N(2) fixation by the accretion method and the (15)N natural abundance method. Nitrogen gained by E. globulus and A. mearnsii mixtures and monocultures was calculated by the accretion method with plant and soil samples collected 10 years after plantation establishment. Nitrogen in biomass and soil confirmed that A. mearnsii influenced N dynamics. Assuming that the differences in soil, forest floor litter and biomass N of plots containing A. mearnsii compared with E. globulus monocultures were due to N(2) fixation, the 10-year annual mean rates of N(2) fixation were 38 and 86 kg ha(-1) year(-1) in 1:1 mixtures and A. mearnsii monocultures, respectively. Nitrogen fixation by A. mearnsii could not be quantified on the basis of the natural abundance of (15)N because such factors as mycorrhization type and fractionation of N isotopes during N cycling within the plant confounded the effect of the N source on the N isotopic signature of plants. This study shows that A. mearnsii fixed significant quantities of N(2) when mixed with E. globulus. A decline in delta(15)N values of E. globulus and A. mearnsii with time, from 2 to 10 years, is further evidence that N(2) was fixed and cycled through the stands. The increased aboveground biomass production of E. globulus trees in mixtures when compared with monocultures can be attributed to increases in N availability.
Swider, P.; Guérin, G.; Baas, Joergen; Søballe, Kjeld; Bechtold, Joan E.
2013-01-01
Orthopaedic implant fixation is strongly dependant upon the effective mechanical properties of newly formed tissue. In this study, we evaluated the potential of modal analysis to derive viscoelastic properties of periprosthetic tissue. We hypothesized that Young's modulus and loss factor could be obtained by a combined theoretical, computational and experimental modal analysis approach. This procedure was applied to ex vivo specimens from a cylindrical experimental implant placed in cancellous bone in an unloaded press-fit configuration, obtained after a four week observation period. Four sections each from seven textured titanium implants were investigated. The first resonant frequency and loss factor were measured. Average experimentally determined loss factor was 2% (SD 0.4%) and average first resonant frequency was 2.1 KHz (SD: 50). A 2D axisymmetric finite element (FE) model identified effective Young's modulus of tissue using experimental resonant frequencies as input. Average value was 42 MPa (SD: 2.4) and no significant difference between specimens was observed. In this pilot study, the non-destructive method allowed accurate measure of dynamic loss factor and resonant frequency and derivation of effective Young's modulus. Prior to implementing this dynamic protocol for broader mechanical evaluation of experimental implant fixation, further work is needed to determine if this affects results from subsequent destructive shear push-out tests. PMID:19464687
Feng, Dan; Wang, Yanwei; Lu, Tiegang; Zhang, Zhiguo; Han, Xiao
2017-01-01
Plant leaves exhibit differentiated patterns of photosynthesis rates under diurnal light regulation. Maize leaves show a single-peak pattern without photoinhibition at midday when the light intensity is maximized. This mechanism contributes to highly efficient photosynthesis in maize leaves. To understand the molecular basis of this process, an isobaric tag for relative and absolute quantitation (iTRAQ)-based proteomics analysis was performed to reveal the dynamic pattern of proteins related to photosynthetic reactions. Steady, single-peak and double-peak protein expression patterns were discovered in maize leaves, and antenna proteins in these leaves displayed a steady pattern. In contrast, the photosystem, carbon fixation and citrate pathways were highly controlled by diurnal light intensity. Most enzymes in the limiting steps of these pathways were major sites of regulation. Thus, maize leaves optimize photosynthesis and carbon fixation outside of light harvesting to adapt to the changes in diurnal light intensity at the protein level.
Warabi, Tateo; Furuyama, Hiroyasu; Sugai, Eri; Kato, Masamichi; Yanagisawa, Nobuo
2018-01-01
This study examined how gait bradykinesia is changed by the motor programming in Parkinson's disease. Thirty-five idiopathic Parkinson's disease patients and nine age-matched healthy subjects participated in this study. After the patients fixated on a visual-fixation target (conditioning-stimulus), the voluntary-gait was triggered by a visual on-stimulus. While the subject walked on a level floor, soleus, tibialis anterior EMG latencies, and the y-axis-vector of the sole-floor reaction force were examined. Three paradigms were used to distinguish between the off-/on-latencies. The gap-task: the visual-fixation target was turned off; 200 ms before the on-stimulus was engaged (resulting in a 200 ms-gap). EMG latency was not influenced by the visual-fixation target. The overlap-task: the on-stimulus was turned on during the visual-fixation target presentation (200 ms-overlap). The no-gap-task: the fixation target was turned off and the on-stimulus was turned on simultaneously. The onset of EMG pause following the tonic soleus EMG was defined as the off-latency of posture (termination). The onset of the tibialis anterior EMG burst was defined as the on-latency of gait (initiation). In the gap-task, the on-latency was unchanged in all of the subjects. In Parkinson's disease, the visual-fixation target prolonged both the off-/on-latencies in the overlap-task. In all tasks, the off-latency was prolonged and the off-/on-latencies were unsynchronized, which changed the synergic movement to a slow, short-step-gait. The synergy of gait was regulated by two independent sensory-motor programs of the off- and on-latency levels. In Parkinson's disease, the delayed gait initiation was due to the difficulty in terminating the sensory-motor program which controls the subject's fixation. The dynamic gait bradykinesia was involved in the difficulty (long off-latency) in terminating the motor program of the prior posture/movement.
The Role of Nitrogen Fixation in Cyanobacterial Bloom Toxicity in a Temperate, Eutrophic Lake
Beversdorf, Lucas J.; Miller, Todd R.; McMahon, Katherine D.
2013-01-01
Toxic cyanobacterial blooms threaten freshwaters worldwide but have proven difficult to predict because the mechanisms of bloom formation and toxin production are unknown, especially on weekly time scales. Water quality management continues to focus on aggregated metrics, such as chlorophyll and total nutrients, which may not be sufficient to explain complex community changes and functions such as toxin production. For example, nitrogen (N) speciation and cycling play an important role, on daily time scales, in shaping cyanobacterial communities because declining N has been shown to select for N fixers. In addition, subsequent N pulses from N2 fixation may stimulate and sustain toxic cyanobacterial growth. Herein, we describe how rapid early summer declines in N followed by bursts of N fixation have shaped cyanobacterial communities in a eutrophic lake (Lake Mendota, Wisconsin, USA), possibly driving toxic Microcystis blooms throughout the growing season. On weekly time scales in 2010 and 2011, we monitored the cyanobacterial community in a eutrophic lake using the phycocyanin intergenic spacer (PC-IGS) region to determine population dynamics. In parallel, we measured microcystin concentrations, N2 fixation rates, and potential environmental drivers that contribute to structuring the community. In both years, cyanobacterial community change was strongly correlated with dissolved inorganic nitrogen (DIN) concentrations, and Aphanizomenon and Microcystis alternated dominance throughout the pre-toxic, toxic, and post-toxic phases of the lake. Microcystin concentrations increased a few days after the first significant N2 fixation rates were observed. Then, following large early summer N2 fixation events, Microcystis increased and became most abundant. Maximum microcystin concentrations coincided with Microcystis dominance. In both years, DIN concentrations dropped again in late summer, and N2 fixation rates and Aphanizomenon abundance increased before the lake mixed in the fall. Estimated N inputs from N2 fixation were large enough to supplement, or even support, the toxic Microcystis blooms. PMID:23405255
The emergence and early evolution of biological carbon-fixation.
Braakman, Rogier; Smith, Eric
2012-01-01
The fixation of CO₂ into living matter sustains all life on Earth, and embeds the biosphere within geochemistry. The six known chemical pathways used by extant organisms for this function are recognized to have overlaps, but their evolution is incompletely understood. Here we reconstruct the complete early evolutionary history of biological carbon-fixation, relating all modern pathways to a single ancestral form. We find that innovations in carbon-fixation were the foundation for most major early divergences in the tree of life. These findings are based on a novel method that fully integrates metabolic and phylogenetic constraints. Comparing gene-profiles across the metabolic cores of deep-branching organisms and requiring that they are capable of synthesizing all their biomass components leads to the surprising conclusion that the most common form for deep-branching autotrophic carbon-fixation combines two disconnected sub-networks, each supplying carbon to distinct biomass components. One of these is a linear folate-based pathway of CO₂ reduction previously only recognized as a fixation route in the complete Wood-Ljungdahl pathway, but which more generally may exclude the final step of synthesizing acetyl-CoA. Using metabolic constraints we then reconstruct a "phylometabolic" tree with a high degree of parsimony that traces the evolution of complete carbon-fixation pathways, and has a clear structure down to the root. This tree requires few instances of lateral gene transfer or convergence, and instead suggests a simple evolutionary dynamic in which all divergences have primary environmental causes. Energy optimization and oxygen toxicity are the two strongest forces of selection. The root of this tree combines the reductive citric acid cycle and the Wood-Ljungdahl pathway into a single connected network. This linked network lacks the selective optimization of modern fixation pathways but its redundancy leads to a more robust topology, making it more plausible than any modern pathway as a primitive universal ancestral form.
Index metacarpal fracture after tightrope suspension following trapeziectomy: case report.
Khalid, Mohammed; Jones, Matthew L
2012-03-01
Trapeziectomy, by itself or combined with ligament reconstruction/interposition arthroplasty, is commonly performed for advanced trapezial-metacarpal arthritis. Several methods and materials, both autogenous and artificial, are commonly used for ligament reconstruction and interposition arthroplasty. Harvesting autologous tendons adds to operative time and could increase potential surgical complications. Using an artificial material would, in theory, avoid some of these problems. However, this approach is not without its problems. We present a case of index metacarpal fracture after using the Arthrex Mini TightRope (Arthrex, Naples, FL) suture button fixation of the thumb and index metacarpals after complete trapeziectomy. Copyright © 2012 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Tegos, Stergios; Charitidis, Charalampos; Korovessis, Panagiotis G
2014-04-01
Retrospective study on circumferential hybrid instrumentation with posterior lumbar interbody fusion (PLIF) and the novel posterior Universal Clamp (UC) instrumentation. This study evaluated the roentgenographic and clinical outcome after PLIF with PEEK cage augmented with UC posterior sublaminar fixation without posterior fusion. Although UC has been successfully used in scoliosis surgery, to our knowledge, this is the first report on its use in degenerative lumbosacral disease. Rigid pedicle screw lumbosacral fixation is associated with several intraoperative screw-related complications. The use of sublaminar bands and rods combined with PEEK PLIF should increase fusion rate and avoid screw-related complications. From a total of 295 consecutive patients who experienced degenerative lumbosacral disease and received posterior decompression, implantation of PLIF with PEEK cages and semirigid posterior fixation with sublaminar UC bands-rods without posterolateral fusion, 150 patients were eligible for this study with a follow-up of more than 2 years. Interbody fusion rate and global plus segmental sagittal spinal lordosis restoration were recorded pre- and postoperatively. Visual analogue scale and Oswestry Disability Index were used to assess functional outcome. Hybrid instrumentation expanded over 1 to 5 levels. Surgical time ranged from 45 to 225 minutes. Only 12.6% of the patients were transfused. There was no nerve root lesion or deep wound infection. Laminar fracture occurred intraoperatively in one case during band insertion. Interbody fusion was achieved in 94% of the operated segments. Lumbar lordosis improved from -36 ± 9° preoperatively to -53 ± 6° postoperatively. Segmental lordosis improved in L4-L5 segment from -5 ± 3° preoperatively to -12 ± 2° postoperatively and in L5-S1 from -9 ± 4° to -14 ± 2° postoperation. Oswestry Disability Index score improved from 44.9 preoperatively to 2.2 postoperatively (P < 0.001). No patient required further spinal surgery until the final evaluation. UC, a novel semirigid sublaminar posterior instrumentation, combined with wedge-shaped PEEK PLIF corrected both global and segmental sagittal lumbar alignment and achieved fusion rate similar to that historically reported with pedicle screw-PLIF techniques, however, avoiding intraoperative complications associated with the use of pedicle screws.
The dynamics of genetic draft in rapidly adapting populations.
Kosheleva, Katya; Desai, Michael M
2013-11-01
The accumulation of beneficial mutations on competing genetic backgrounds in rapidly adapting populations has a striking impact on evolutionary dynamics. This effect, known as clonal interference, causes erratic fluctuations in the frequencies of observed mutations, randomizes the fixation times of successful mutations, and leaves distinct signatures on patterns of genetic variation. Here, we show how this form of "genetic draft" affects the forward-time dynamics of site frequencies in rapidly adapting asexual populations. We calculate the probability that mutations at individual sites shift in frequency over a characteristic timescale, extending Gillespie's original model of draft to the case where many strongly selected beneficial mutations segregate simultaneously. We then derive the sojourn time of mutant alleles, the expected fixation time of successful mutants, and the site frequency spectrum of beneficial and neutral mutations. Finally, we show how this form of draft affects inferences in the McDonald-Kreitman test and how it relates to recent observations that some aspects of genetic diversity are described by the Bolthausen-Sznitman coalescent in the limit of very rapid adaptation.
Electron microscopy approach for the visualization of the epithelial and endothelial glycocalyx.
Chevalier, L; Selim, J; Genty, D; Baste, J M; Piton, N; Boukhalfa, I; Hamzaoui, M; Pareige, P; Richard, V
2017-06-01
This study presents a methodological approach for the visualization of the glycocalyx by electron microscopy. The glycocalyx is a three dimensional network mainly composed of glycolipids, glycoproteins and proteoglycans associated with the plasma membrane. Since less than a decade, the epithelial and endothelial glycocalyx proved to play an important role in physiology and pathology, increasing its research interest especially in vascular functions. Therefore, visualization of the glycocalyx requires reliable techniques and its preservation remains challenging due to its fragile and dynamic organization, which is highly sensitive to the different process steps for electron microscopy sampling. In this study, chemical fixation was performed by perfusion as a good alternative to conventional fixation. Additional lanthanum nitrate in the fixative enhances staining of the glycocalyx in transmission electron microscopy bright field and improves its visualization by detecting the elastic scattered electrons, thus providing a chemical contrast. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
NO gas loss from biologically crusted soils in Canyonlands National Park, Utah
Barger, N.N.; Belnap, J.; Ojima, D.S.; Mosier, A.
2005-01-01
In this study, we examined N gas loss as nitric oxide (NO) from N-fixing biologically crusted soils in Canyonlands National Park, Utah. We hypothesized that NO gas loss would increase with increasing N fixation potential of the biologically crusted soil. NO fluxes were measured from biologically crusted soils with three levels of N fixation potential (Scytonema-Nostoc-Collema spp. (dark)>Scytonema-Nostoc-Microcoleus spp. (medium)>Microcoleus spp. (light)) from soil cores and field chambers. In both cores and field chambers there was a significant effect of crust type on NO fluxes, but this was highly dependent on season. NO fluxes from field chambers increased with increasing N fixation potential of the biologically crusted soils (dark>medium>light) in the summer months, with no differences in the spring and autumn. Soil chlorophyllasis Type a content (an index of N fixation potential), percent N, and temperature explained 40% of the variability in NO fluxes from our field sites. Estimates of annual NO loss from dark and light crusts was 0.04-0.16 and 0.02-0.11-N/ha/year. Overall, NO gas loss accounts for approximately 3-7% of the N inputs via N fixation in dark and light biologically crusted soils. Land use practices have drastically altered biological soil crusts communities over the past century. Livestock grazing and intensive recreational use of public lands has resulted in a large scale conversion of dark cyanolichen crusts to light cyanobacterial crusts. As a result, changes in biologically crusted soils in arid and semi-arid regions of the western US may subsequently impact regional NO loss. ?? Springer 2005.
Park, Sang Min; Kim, Ho Joong; Lee, Se Yeon; Chang, Bong Soon; Lee, Choon Ki; Yeom, Jin S
2018-05-01
We prospectively assessed the early radiographic and clinical outcomes (minimum follow-up of 2 years) of robot-assisted pedicle screw fixation (Robot-PSF) and conventional freehand pedicle screw fixation (Conv-PSF). Patients were randomly assigned to Robot-PSF (37 patients) or Conv-PSF (41 patients) for posterior interbody fusion surgery. The Robot-PSF group underwent minimally invasive pedicle screw fixation using a pre-planned robot-guided screw trajectory. The Conv-PSF underwent screw fixation using the freehand technique. Radiographic adjacent segment degeneration (ASD) was measured on plain radiographs, and clinical outcomes were measured using visual analogue scale (VAS) and Oswestry disability index (ODI) scores regularly after surgery. The two groups had similar values for radiographic ASD, including University California at Los Angeles grade, vertebral translation, angular motion, and loss of disc height (p=0.320). At final follow-up, both groups had experienced significant improvements in back VAS, leg VAS, and ODI scores after surgery (p<0.001), although inter-group differences were not significant for back VAS (p=0.876), leg VAS (p=0.429), and ODI scores (p=0.952). In the Conv-PSF group, revision surgery was required for two of the 25 patients (8%), compared to no patients in the Robot-PSF group. There were no significant differences in radiographic ASD and clinical outcomes between Robot-PSF and Conv-PSF. Thus, the advantages of robot-assisted surgery (accurate pedicle screw insertion and minimal facet joint violation) do not appear to be clinically significant. © Copyright: Yonsei University College of Medicine 2018.
This EnviroAtlas dataset contains data on the mean cultivated biological nitrogen fixation (C-BNF) in cultivated crop and hay/pasture lands per 12-digit Hydrologic Unit (HUC) in 2006. Nitrogen (N) inputs from the cultivation of legumes, which possess a symbiotic relationship with N-fixing bacteria, were calculated with a recently developed model relating county-level yields of various leguminous crops with BNF rates. We accessed county-level data on annual crop yields for soybeans (Glycine max L.), alfalfa (Medicago sativa L.), peanuts (Arachis hypogaea L.), various dry beans (Phaseolus, Cicer, and Lens spp.), and dry peas (Pisum spp.) for 2006 from the USDA Census of Agriculture (http://www.agcensus.usda.gov/index.php). We estimated the yield of the non-alfalfa leguminous component of hay as 32% of the yield of total non-alfalfa hay (http://www.agcensus.usda.gov/index.php). Annual rates of C-BNF by crop type were calculated using a model that relates yield to C-BNF. We assume yield data reflect differences in soil properties, water availability, temperature, and other local and regional factors that can influence root nodulation and rate of N fixation. We distributed county-specific, C-BNF rates to cultivated crop and hay/pasture lands delineated in the 2006 National Land Cover Database (30 x 30 m pixels) within the corresponding county. C-BNF data described here represent an average input to a typical agricultural land type within a county, i.e., they are not
Laubscher, M; Mitchell, C; Timms, A; Goodier, D; Calder, P
2016-10-01
Patients undergoing femoral lengthening by external fixation tolerate treatment less well when compared to tibial lengthening. Lengthening of the femur with an intramedullary device may have advantages. We reviewed all cases of simple femoral lengthening performed at our unit from 2009 to 2014. Cases of nonunions, concurrent deformities, congenital limb deficiencies and lengthening with an unstable hip were excluded, leaving 33 cases (in 22 patients; 11 patients had bilateral procedures) for review. Healing index, implant tolerance and complications were compared. In 20 cases (15 patients) the Precice lengthening nail was used and in 13 cases (seven patients) the LRS external fixator system. The desired length was achieved in all cases in the Precice group and in 12 of 13 cases in the LRS group. The mean healing index was 31.3 days/cm in the Precice and 47.1 days/cm in the LRS group (p < 0.001). This was associated with an earlier ability to bear full weight without aids in the Precice group. There were more complications with LRS lengthening, including pin site infections and regenerate deformity. Implant tolerance and the patients' perception of the cosmetic result were better with the Precice treatment. Femoral lengthening with the Precice femoral nail achieved excellent functional results with fewer complications and greater patient satisfaction when compared with the LRS system in our patients. Cite this article: Bone Joint J 2016;98-B:1382-8. ©2016 The British Editorial Society of Bone & Joint Surgery.
Effects of some motion sickness suppressants on tracking performance during angular accelerations.
DOT National Transportation Integrated Search
1982-10-01
The two studies reported here examined the influence of three established antimotion sickness drugs on tracking performance in static (stationary) and dynamic (angular acceleration) conditions and on visual fixation ability during motion. : In Study ...
Gundale, Michael J.; Bach, Lisbet H.; Nordin, Annika
2013-01-01
Bryophytes achieve substantial biomass and play several key functional roles in boreal forests that can influence how carbon (C) and nitrogen (N) cycling respond to atmospheric deposition of reactive nitrogen (Nr). They associate with cyanobacteria that fix atmospheric N2, and downregulation of this process may offset anthropogenic Nr inputs to boreal systems. Bryophytes also promote soil C accumulation by thermally insulating soils, and changes in their biomass influence soil C dynamics. Using a unique large-scale (0.1 ha forested plots), long-term experiment (16 years) in northern Sweden where we simulated anthropogenic Nr deposition, we measured the biomass and N2-fixation response of two bryophyte species, the feather mosses Hylocomium splendens and Pleurozium schreberi. Our data show that the biomass declined for both species; however, N2-fixation rates per unit mass and per unit area declined only for H. splendens. The low and high treatments resulted in a 29% and 54% reduction in total feather moss biomass, and a 58% and 97% reduction in total N2-fixation rate per unit area, respectively. These results help to quantify the sensitivity of feather moss biomass and N2 fixation to chronic Nr deposition, which is relevant for modelling ecosystem C and N balances in boreal ecosystems. PMID:24196519
Aiyer, Amiethab; Russell, Nicholas A; Pelletier, Matthew H; Myerson, Mark; Walsh, William R
2016-06-01
Background The optimal fixation method for the first tarsometatarsal arthrodesis remains controversial. This study aimed to develop a reproducible first tarsometatarsal testing model to evaluate the biomechanical performance of different reconstruction techniques. Methods Crossed screws or a claw plate were compared with a single or double shape memory alloy staple configuration in 20 Sawbones models. Constructs were mechanically tested in 4-point bending to 1, 2, and 3 mm of plantar displacement. The joint contact force and area were measured at time zero, and following 1 and 2 mm of bending. Peak load, stiffness, and plantar gapping were determined. Results Both staple configurations induced a significantly greater contact force and area across the arthrodesis than the crossed screw and claw plate constructs at all measurements. The staple constructs completely recovered their plantar gapping following each test. The claw plate generated the least contact force and area at the joint interface and had significantly greater plantar gapping than all other constructs. The crossed screw constructs were significantly stiffer and had significantly less plantar gapping than the other constructs, but this gapping was not recoverable. Conclusions Crossed screw fixation provides a rigid arthrodesis with limited compression and contact footprint across the joint. Shape memory alloy staples afford dynamic fixation with sustained compression across the arthrodesis. A rigid polyurethane foam model provides an anatomically relevant comparison for evaluating the interface between different fixation techniques. Clinical Relevance The dynamic nature of shape memory alloy staples offers the potential to permit early weight bearing and could be a useful adjunctive device to impart compression across an arthrodesis of the first tarsometatarsal joint. Therapeutic, Level V: Bench testing. © 2015 The Author(s).
Rice, Katherine; Moriuchi, Jennifer M; Jones, Warren; Klin, Ami
2012-03-01
To examine patterns of variability in social visual engagement and their relationship to standardized measures of social disability in a heterogeneous sample of school-aged children with autism spectrum disorders (ASD). Eye-tracking measures of visual fixation during free-viewing of dynamic social scenes were obtained for 109 children with ASD (mean age, 10.2 ± 3.2 years), 37 of whom were matched with 26 typically-developing (TD) children (mean age, 9.5 ± 2.2 years) on gender, age, and IQ. The smaller subset allowed between-group comparisons, whereas the larger group was used for within-group examinations of ASD heterogeneity. Between-group comparisons revealed significantly attenuated orientation to socially salient aspects of the scenes, with the largest effect size (Cohen's d = 1.5) obtained for reduced fixation on faces. Within-group analyses revealed a robust association between higher fixation on the inanimate environment and greater social disability. However, the associations between fixation on the eyes and mouth and social adaptation varied greatly, even reversing, when comparing different cognitive profile subgroups. Although patterns of social visual engagement with naturalistic social stimuli are profoundly altered in children with ASD, the social adaptivity of these behaviors varies for different groups of children. This variation likely represents different patterns of adaptation and maladaptation that should be traced longitudinally to the first years of life, before complex interactions between early predispositions and compensatory learning take place. We propose that variability in these early mechanisms of socialization may serve as proximal behavioral manifestations of genetic vulnerabilities. Copyright © 2012 American Academy of Child and Adolescent Psychiatry. Published by Elsevier Inc. All rights reserved.
Parslow, A; Simpson, D J
2017-06-01
A very limited safe anatomical window for transiliosacral implant placement exists in cats (<0·5 cm 2 ). Lag screw fixation requires multiple bilateral implants thus increasing the risk of iatrogenic trauma and implant interference. We describe a safe and effective method for bilateral sacroiliac fixation in cats using a single implant to minimise inadvertent iatrogenic damage to local structures and restore pelvic canal diameter. Eight cats underwent surgical fixation for traumatic bilateral sacroiliac luxation using a single smooth intramedullary pin. The pin spanned both ilial wings and sacrum. Implants were applied using a Universal C-guide. Pre- and postsurgery pelvic canal diameter ratios were calculated. Short-term follow-up was performed at 10 to 14 days postoperatively. Long-term follow-up was performed using the Feline Musculoskeletal Pain Index Questionnaire. Long-term radiographic assessment was available in two cases. The technique achieved safe and accurate implant position with precise sacroiliac joint reduction. Pelvic canal diameter ratios were restored to normal in all cases. Rapid return to normal hind leg function and excellent long-term clinical outcomes were achieved. This technique offers a simple, safe, repeatable and affordable technique for treating bilateral sacroiliac luxations in the cat without the aid of fluoroscopy. The procedure can be performed using surgical tools and inventory readily available in general small animal practices. © 2017 British Small Animal Veterinary Association.
Treatment Approach for Infection of Healed Fractures After Internal Fixation.
Lawrenz, Joshua M; Frangiamore, Salvatore J; Rane, Ajinkya A; Cantrell, William Alex; Vallier, Heather A
2017-11-01
To review the efficacy of a treatment approach for patients with infection and colonized implants after open reduction and internal fixation of fractures. Retrospective case series. Level one trauma center. Twenty patients were treated for wound infection with colonized implants after open reduction and internal fixation. Surgical debridement, removal of implants, and a short postoperative oral antibiotic course. The course of patients after surgical debridement and removal of implants, including culture results, antibiotic administration, and presence of recurrent clinical infection and radiographic union. Twenty patients had clinical presentations, including skin breakdown, serous drainage, purulent drainage and/or exposed implants, most commonly of the tibia (15 of 20). Mean time from index procedure to debridement with implant removal was 19.7 months. At the time of debridement and implant removal, 18 of 20 (90%) patients had a positive intraoperative culture (16 routine cultures and 2 broth cultures). The most common bacteria were Enterobacter cloacae (5/17) and methicillin-sensitive Staphylococcus aureus (4/17). All patients had soft tissue healing without signs of recurrent infection after mean follow up of 40 months after implant removal. Surgical debridement with implant removal plus a short oral antibiotic course is effective to resolve wound infection with a colonized implant in the setting of healed fracture after internal fixation. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Percutaneous distraction lengthening in brachymetacarpia.
Volpi, Alexander D; Fragomen, Austin T
2011-08-08
Brachymetacarpia is a condition manifesting a shortened metacarpal that is caused by early closure of the epiphyseal plate and believed to arise idiopathically. The correction for brachymetacarpia is usually for cosmetic reasons as brachymetacarpia does not impair function. The literature indicates several different approaches to lengthening digits, including single-stage lengthening and rapid distraction lengthening with a bone graft. However, gradual distraction is the preferred method due to excellent cosmetic outcomes and few postoperative complications. This article reports a case of brachymetacarpia treated with distraction lengthening using a minimally invasive, percutaneous approach. A 16-year-old girl presented with a shortened left ring finger and underwent surgery to correct the deformity. The left ring finger measured 12 mm shorter than her right ring finger; however, there was normal mobility at the joints. In the operating room, an external fixator was attached using 4 self-drilling, self-tapping pins through several 3-mm skin incisions. The total fixation time was 14 weeks; however, the achieved length of 12 mm was achieved 6 weeks postoperatively. The healing index of the fixation period was 81 days/cm. The postoperative course and fixation period were uneventful, with no complications except for 2 pin infections that were treated with oral antibiotics. The method of gradual distraction lengthening in this case successfully achieved the desired length and yielded an excellent cosmetic result. Copyright 2011, SLACK Incorporated.
Obid, Peter; Danyali, Reza; Kueny, Rebecca; Huber, Gerd; Reichl, Michael; Richter, Alexander; Niemeyer, Thomas; Morlock, Michael; Püschel, Klaus; Übeyli, Hüseyin
2017-02-01
Ex vivo human cadaveric study. The development or progression of adjacent segment disease (ASD) after spine stabilization and fusion is a major problem in spine surgery. Apart from optimal balancing of the sagittal profile, dynamic instrumentation is often suggested to prevent or impede ASD. Hybrid instrumentation is used to gain stabilization while allowing motion to avoid hypermobility in the adjacent segment. In this biomechanical study, the effects of two different hybrid instrumentations on human cadaver spines were evaluated and compared with a rigid instrumentation. Eighteen human cadaver spines (T11-L5) were subdivided into three groups: rigid, dynamic, and hook comprising six spines each. Clinical parameters and initial mechanical characteristics were consistent among groups. All specimens received rigid fixation from L3-L5 followed by application of a free bending load of extension and flexion. The range of motion (ROM) for every segment was evaluated. For the rigid group, further rigid fixation from L1-L5 was applied. A dynamic Elaspine system (Spinelab AG, Winterthur, Switzerland) was applied from L1 to L3 for the dynamic group, and the hook group was instrumented with additional laminar hooks at L1-L3. ROM was then evaluated again. There was no significant difference in ROM among the three instrumentation techniques. Based on this data, the intended advantage of a hybrid or dynamic instrumentation might not be achieved.
Eric A. Kuehler; Mary Anne Sword Sayer; James D. Haywood; C. Dan Andries
2004-01-01
Depending on the season and intensity of fire, as well as the phenology of foliage and new root growth, fire may damage foliage, and subsequently decrease whole-crown carbon fixation and allocation to the root system. In central Louisiana the authors investigated how season of prescribed burning affects fine-root dynamics, root carbohydrate relations, and leaf area...
2016-10-01
characterization of a novel external fixator for dynamizing ovine osseous defects. Poster No. 2185. Orthopedic Research Society Annual Meeting, Orlando...REPORT: Annual PREPARED FOR: U.S. Army Medical Research and Materiel Command Fort Detrick, Maryland 21702-5012 DISTRIBUTION STATEMENT...SPONSOR/MONITOR’S ACRONYM(S) U.S. Army Medical Research and Materiel Command Fort Detrick, Maryland 21702-5012 11. SPONSOR/MONITOR’S REPORT NUMBER(S
Lazarides, Alexander L; Hamid, Kamran S; Kerzner, Michael S
2018-04-01
Open reduction with external fixation (OREF) utilizing fine wire ringed fixators for correction of Charcot deformity has gained popularity over the past decade. Pin site infections are a well-documented complication of external fixation as well as a driver of escalating health care costs. We aimed to demonstrate the safety and efficacy of a novel method of pin site care utilizing active Leptospermum honey-impregnated dressings (MediHoney) in diabetic patients undergoing deformity correction with OREF. Twenty-one diabetic patients with Charcot deformities of the lower extremity were prospectively enrolled and followed for pin site complications following OREF for deformity correction. Active Leptospermum honey dressings were applied at metal-cutaneous interfaces at the end of the OREF procedure and replaced weekly for a total of 8 weeks. Patients were monitored for pin site infections from the time of surgery until external fixator removal. Sixteen consecutive patients receiving standard OREF for Charcot deformities were evaluated retrospectively to serve as a control group. Of the 21 enrolled patients, 19 underwent OREF and followed up throughout the study period. Treated patients had a mean age of 58.5 years and mean body mass index measuring 33.3 kg/m 2 as documented prior to surgery. The 15 patients with hemoglobin A1c labs drawn in the 3 months preceding surgery averaged 7.5. Fixators were removed at an average of 12.1 weeks after adequate bony healing. Of the 244 pin sites in 19 patients, 3 pin sites (1.2% of pins) in 2 patients (10.5% of patients) showed evidence of superficial infection. All infections resolved with oral antibiotics. Infection rates were significantly reduced when compared to the standard care control group. Pilot data in a prospectively collected case series demonstrate safety and efficacy of active Leptospermum honey-impregnated dressings when used for fine wire ringed fixator pin site care in diabetic Charcot deformity patients. Further investigation in the form of a prospective randomized controlled study is warranted to demonstrate the potential value of this novel intervention. Level IV.
Hindersin, Laura; Traulsen, Arne
2015-11-01
We analyze evolutionary dynamics on graphs, where the nodes represent individuals of a population. The links of a node describe which other individuals can be displaced by the offspring of the individual on that node. Amplifiers of selection are graphs for which the fixation probability is increased for advantageous mutants and decreased for disadvantageous mutants. A few examples of such amplifiers have been developed, but so far it is unclear how many such structures exist and how to construct them. Here, we show that almost any undirected random graph is an amplifier of selection for Birth-death updating, where an individual is selected to reproduce with probability proportional to its fitness and one of its neighbors is replaced by that offspring at random. If we instead focus on death-Birth updating, in which a random individual is removed and its neighbors compete for the empty spot, then the same ensemble of graphs consists of almost only suppressors of selection for which the fixation probability is decreased for advantageous mutants and increased for disadvantageous mutants. Thus, the impact of population structure on evolutionary dynamics is a subtle issue that will depend on seemingly minor details of the underlying evolutionary process.
Ilizarov bone transport versus fibular graft for reconstruction of tibial bone defects in children.
Abdelkhalek, Mostafa; El-Alfy, Barakat; Ali, Ayman M
2016-11-01
The aim of this study was to compare the results of treatment of segmental tibial defects in the pediatric age group using an Ilizarov external fixator versus a nonvascularized fibular bone graft. This study included 24 patients (age range from 5.5 to 15 years) with tibial bone defects: 13 patients were treated with bone transport (BT) and 11 patients were treated with a nonvascularized fibular graft (FG). The outcome parameters were bone results (union, deformity, infection, leg-length discrepancy) and functional results: external fixation index and external fixation time. In group A (BT), one patient developed refracture at the regenerate site, whereas, in group B (FG), after removal of the external fixator, one of the FGs developed a stress fracture. The external fixator time in group A was 10.7 months (range 8-14.5) versus 7.8 months (range 4-11.5 months) in group B (FG). In group A (BT), one patient had a limb-length discrepancy (LLD), whereas, in group B (FG), three patients had LLD. The functional and bone results of the Ilizarov BT technique were excellent in 23.1 and 30.8%, good in 38.5 and 46.2, fair in 30.8 and 15.4, and poor in 7.6 and 7.6%, respectively. The poor functional result was related to the poor bone result because of prolonged external fixator time resulting in significant pain, limited ankle motion, whereas the functional and bone results of fibular grafting were excellent in 9.1 and 18.2%, good in 63.6 and 45.5%, fair in 18.2 and 27.2%, and poor in 9.1 and 9.1%, respectively. Segmental tibial defects can be effectively treated with both methods. The FG method provides satisfactory results, with early removal of the external fixator. However, it had a limitation in patients with severe infection and those with LLD. Also, it requires a long duration of limb bracing until adequate hypertrophy of the graft. The Ilizarov method has the advantages of early weight bearing, treatment of postinfection bone defect in a one-stage surgery, and the possibility to treat the associated LLD. However, it has a long external fixation time.
Smith, Tim J; Mital, Parag K
2013-07-17
Does viewing task influence gaze during dynamic scene viewing? Research into the factors influencing gaze allocation during free viewing of dynamic scenes has reported that the gaze of multiple viewers clusters around points of high motion (attentional synchrony), suggesting that gaze may be primarily under exogenous control. However, the influence of viewing task on gaze behavior in static scenes and during real-world interaction has been widely demonstrated. To dissociate exogenous from endogenous factors during dynamic scene viewing we tracked participants' eye movements while they (a) freely watched unedited videos of real-world scenes (free viewing) or (b) quickly identified where the video was filmed (spot-the-location). Static scenes were also presented as controls for scene dynamics. Free viewing of dynamic scenes showed greater attentional synchrony, longer fixations, and more gaze to people and areas of high flicker compared with static scenes. These differences were minimized by the viewing task. In comparison with the free viewing of dynamic scenes, during the spot-the-location task fixation durations were shorter, saccade amplitudes were longer, and gaze exhibited less attentional synchrony and was biased away from areas of flicker and people. These results suggest that the viewing task can have a significant influence on gaze during a dynamic scene but that endogenous control is slow to kick in as initial saccades default toward the screen center, areas of high motion and people before shifting to task-relevant features. This default-like viewing behavior returns after the viewing task is completed, confirming that gaze behavior is more predictable during free viewing of dynamic than static scenes but that this may be due to natural correlation between regions of interest (e.g., people) and motion.
F. Thomas Ledig; M. Thompson Conkle; Basilio Bermejo-Velázquez; Teobaldo Eguiluz-Piedra; Paul D. Hodgskiss; David R. Johnson; William S. Dvorak
1999-01-01
Maxipinon (Pinus maximartinezii Rzedowski), which is confined to a single population of approximately 2000 to 2500 mature trees, covers about 400 ha in southern Zacatecas, Mexico. Genetic diversity measured by expected heterozygosity was 0.122, which is moderate for pines. However, percentage polymorphic loci was low, 30.3%. The fixation index (
USDA-ARS?s Scientific Manuscript database
We generated 13,789 single nucleotide plymorphism (SNP) markers from 97 melon accessions using genotyping by sequencing and anchored them to chromosomes to understand genome-wide fixation index between various melon morphotypes and linkage disequilibrium (LD) decay for inodorus and cantalupensis, th...
iNJclust: Iterative Neighbor-Joining Tree Clustering Framework for Inferring Population Structure.
Limpiti, Tulaya; Amornbunchornvej, Chainarong; Intarapanich, Apichart; Assawamakin, Anunchai; Tongsima, Sissades
2014-01-01
Understanding genetic differences among populations is one of the most important issues in population genetics. Genetic variations, e.g., single nucleotide polymorphisms, are used to characterize commonality and difference of individuals from various populations. This paper presents an efficient graph-based clustering framework which operates iteratively on the Neighbor-Joining (NJ) tree called the iNJclust algorithm. The framework uses well-known genetic measurements, namely the allele-sharing distance, the neighbor-joining tree, and the fixation index. The behavior of the fixation index is utilized in the algorithm's stopping criterion. The algorithm provides an estimated number of populations, individual assignments, and relationships between populations as outputs. The clustering result is reported in the form of a binary tree, whose terminal nodes represent the final inferred populations and the tree structure preserves the genetic relationships among them. The clustering performance and the robustness of the proposed algorithm are tested extensively using simulated and real data sets from bovine, sheep, and human populations. The result indicates that the number of populations within each data set is reasonably estimated, the individual assignment is robust, and the structure of the inferred population tree corresponds to the intrinsic relationships among populations within the data.
Development of the eye-movement response in the trainee radiologist
NASA Astrophysics Data System (ADS)
Wooding, David S.; Roberts, Geraint M.; Phillips-Hughes, Jane
1999-05-01
In order to explore the initial response of the visual system to radiological images in groups of individuals with increasing degrees of radiological training and experience, the locations of fixations made during visual inspection of digitized chest radiographs were examined for 4 groups of observers: 10 experienced radiologists, 9 first-year 'novice' radiologists, 11 'trainee' radiologists in the second and third years of their training, and 7 native controls. Each observer viewed 12 digitized chest radiographs (6 normal and 6 showing some abnormality) in a VDU for 8s each. Eye movements were recorded throughout and observers indicated via a button box whether they thought the radiograph to be normal or abnormal. A least squares index was utilized in order to quantify the similarity in fixation location between pairs of eye movement traces over the first 1.5 and 3 seconds of an inspection. The similarities thus produced were then averaged to give intra- and inter-group similarities in fixation location. The fixation locations of experienced radiologists were found to be highly similar as a group, as were those of the novices. While the fixation locations of controls showed less similarity, it was the fixations of trainees which were the least similar (i.e. showed the most variability) within their group. The fixation locations of novices showed a greater similarity to those of radiologists than those of controls, and a decreased similarity to those of controls than those of the controls themselves. However, rather than showing that the fixation locations of individuals become increasing similar to those of radiologists as training progresses, the data show that the more variable fixation locations of trainees are the least similar to those of radiologists than those of any of the groups, even the controls. Control observers examine every day images in a similar way and this is also true of radiological images. Experienced radiologists view radiological images in a similar way to each other, but their training has resulted in differences between them and controls. In becoming experienced radiologists, it appears that trainees may move through a developmental phase characterized by more idiosyncratic eye movements; their eye movements becoming less similar to controls or experienced radiologists than they were. With experience the eye movements of trainee radiologists may become more similar to both groups, but the transition of the trainee from novice to experienced radiologist is not a simple one: the change involves a period of some disorder.
Yang, Jesse Chieh-Szu; Chen, Hsin-Chang; Lai, Yu-Shu; Cheng, Cheng-Kung
2017-01-01
Fixation with a dynamic hip screw (DHS) is one of the most common methods for stabilizing intertrochanteric fractures, except for unstable and reverse oblique fracture types. However, failure is often observed in osteoporotic patients whereby the lag screw effectively 'cuts out' through the weak bone. Novel anti-migration blades have been developed to be used in combination with a lag screw ('Blade Screw') to improve the fixation strength in osteoporotic intertrochanteric fractures. An in-vitro biomechanical study and a retrospective clinical study were performed to evaluate lag screw migration when using the novel Blade Screw and a traditional threaded DHS. The biomechanical study showed both the Blade Screw and DHS displayed excessive migration (≥10 mm) before reaching 20,000 loading cycles in mild osteoporotic bone, but overall migration of the Blade Screw was significantly less (p ≤ 0.03). Among the patients implanted with a Blade Screw in the clinical study, there was no significant variation in screw migration at 3-months follow-up (P = 0.12). However, the patient's implanted with a DHS did display significantly greater migration (P<0.001) than those implanted with the Blade Screw. In conclusion, the Blade Screw stabilizes the bone fragments during dynamic loading so as to provide significantly greater resistance to screw migration in patients with mild osteoporosis.
Voter model with arbitrary degree dependence: clout, confidence and irreversibility
NASA Astrophysics Data System (ADS)
Fotouhi, Babak; Rabbat, Michael G.
2014-03-01
The voter model is widely used to model opinion dynamics in society. In this paper, we propose three modifications to incorporate heterogeneity into the model. We address the corresponding oversimplifications of the conventional voter model which are unrealistic. We first consider the voter model with popularity bias. The influence of each node on its neighbors depends on its degree. We find the consensus probabilities and expected consensus times for each of the states. We also find the fixation probability, which is the probability that a single node whose state differs from every other node imposes its state on the entire system. In addition, we find the expected fixation time. Then two other extensions to the model are proposed and the motivations behind them are discussed. The first one is confidence, where in addition to the states of neighbors, nodes take their own state into account at each update. We repeat the calculations for the augmented model and investigate the effects of adding confidence to the model. The second proposed extension is irreversibility, where one of the states is given the property that once nodes adopt it, they cannot switch back. This is motivated by applications where, agents take an irreversible action such as seeing a movie, purchasing a music album online, or buying a new product. The dynamics of densities, fixation times and consensus times are obtained.
Nitrogen dynamics in an Alaskan salt marsh following spring use by geese
Zacheis, Amy B.; Ruess, Roger W.; Hupp, Jerry W.
2002-01-01
Lesser snow geese (Anser caerulescens caerulescens) and Canada geese (Branta canadensis) use several salt marshes in Cook Inlet, Alaska, as stopover areas for brief periods during spring migration. We investigated the effects of geese on nitrogen cycling processes in Susitna Flats, one of the marshes. We compared net nitrogen mineralization, organic nitrogen pools and production in buried bags, nitrogen fixation by cyanobacteria, and soil and litter characteristics on grazed plots versus paired plots that had been exclosed from grazing for 3 years. Grazed areas had higher rates of net nitrogen mineralization in the spring and there was no effect of grazing on organic nitrogen availability. The increased mineralization rates in grazed plots could not be accounted for by alteration of litter quality, litter quantity, microclimate, or root biomass, which were not different between grazed and exclosed plots. In addition, fecal input was very slight in the year that we studied nitrogen cycling. We propose that trampling had two effects that could account for greater nitrogen availability in grazed areas: litter incorporation into soil, resulting in increased rates of decomposition and mineralization of litter material, and greater rates of nitrogen fixation by cyanobacteria on bare, trampled soils. A path analysis indicated that litter incorporation by trampling played a primary role in the nitrogen dynamics of the system, with nitrogen fixation secondary, and that fecal input was of little importance.
[Stress test and clinical application of the minimal-invasive dynamic hip screw].
Tong, Song-Lin; Chen, Jian-Lie; Lu, Wen-Jie; Pan, Zhi-Jun; Wang, Yi-Jin
2008-05-01
To recognize the effect of minimal-invasive dynamic hip screw (MIDHS) on the treatment of intertrochanteric fracture of the hip by biomechanical test and preliminary clinical application. Ten artifical made intertrochanteric fractures of femoral specimen from five cadavers were divided into two groups randomly. The fractures in first group were fixed by MIDHS and other group were fixed by dynamic hip (DHS). Biomechanical characteristics of two different devices were compared with the biomechanical character of load-straining, load-displacing, rigidity and strength of femur by statistic analysis. According to the Harris evaluation, healing effect of intertrochanteric fractures was evaluated clinically on the 15 cases. Straining changes of MIDHS were 14% and 11% less than that of DHS on the tensile side and the pressure side respectively; Sinking and horizontal displacement, were 19% and 22% less than that of DHS respectivly. But external and internal stress intensity,axial and bending rigidity were all higher than that of DHS, they were 12%, 11%, 19% and 37%. Maximal destroyed twisting moment (15%) and average twisting rigidity (15%) were both higher than that of DHS, but twisting angle was 18% less. Under the force, of 1 800 N, the open angle of the fracture on transverse section was 2.28 degrees,while the DHS's was 3.60 degrees . The data above were significant differences statistically (P < 0.01). The average Harris score of the 15 cases with intertrochanteric fractures treated by MIDHS was 91, excellent and good rate was 92.7%, without complications of internal fixation failure,postoperative infection and so on. The design of minimal-invasive dynamic hip screw is reasonable and effective against rotating, shearing and varus stress force of the fracture, and it provides possibility of implanting the internal fixation with minimal incision. So it is an ideal internal fixation device for the treatment of intertrochanteric fractures.
Kim, Hyun-Ah; Yi, Hyon-Ah; Lee, Hyung
2016-04-01
To investigate the frequency and pattern of failure of the fixation suppression (FFS) of spontaneous nystagmus (SN) in unilateral cerebellar infarction, and to identify the structure responsible for FFS, 29 patients with acute, mainly unilateral, isolated cerebellar infarction who had SN with a predominantly horizontal component were enrolled in this study. The ocular fixation index (OFI) was defined as the mean slow phase velocity (SPV) of the horizontal component of SN with fixation divided by the mean SPV of the horizontal component of SN without fixation. The OFI from age- and sex-matched patients with vestibular neuritis was calculated and used as the control data. The FFS of SN was only found in less than half (41 %, 12/29) of the patients. Approximately 65 % (n = 7) of the patients with isolated anterior inferior cerebellar artery territory cerebellar infarction showed FFS, whereas only a quarter (n = 3) of the patients with isolated posterior inferior cerebellar artery (PICA) territory cerebellar infarction showed FFS. The proportion of gaze-evoked nystagmus (6/12 [50 %] vs. 2/17 [12 %], p = 0.04) and deficient gain of ipsilesional pursuit (10/12 [83 %] vs. 6/17 [35 %], p = 0.05) was more frequent in the FFS group than in the group without FFS. Lesion subtraction analysis in isolated PICA territory cerebellar infarction revealed that the nodulus was commonly damaged in patients with FFS, compared to that of patients without FFS. Our study shows that FFS of SN due to acute cerebellar infarction is less common than previously thought and the nodulus may be an important structure for the suppression of SN in humans.
Xu, Bowen; Zhang, Qingsong; An, Siqi; Pei, Baorui; Wu, Xiaobo
2017-08-01
To establish the model of compression fracture of acetabular dome, and to measure the contact characteristics of acetabular weight-bearing area of acetabulum after 3 kinds of internal fixation. Sixteen fresh adult half pelvis specimens were randomly divided into 4 groups, 4 specimens each group. Group D was the complete acetabulum (control group), and the remaining 3 groups were prepared acetabular dome compression fracture model. The fractures were fixed with reconstruction plate in group A, antegrade raft screws in group B, and retrograde raft screws in group C. The pressure sensitive films were attached to the femoral head, and the axial compression test was carried out on the inverted single leg standing position. The weight-bearing area, average stress, and peak stress were measured in each group. Under the loading of 500 N, the acetabular weight-bearing area was significantly higher in group D than in other 3 groups ( P <0.05), and the average stress and peak stress were significantly lower than in other 3 groups ( P <0.05). The acetabular weight-bearing area were significantly higher in group B and group C than in group A, and the average stress and peak stress were significantly lower than in group A ( P <0.05). There was no significant difference in the above indexes between group B and group C ( P >0.05). For the compression fracture of the acetabular dome, the contact characteristics of the weight-bearing area can not restore to the normal level, even if the anatomical reduction and rigid internal fixation were performed; compared with the reconstruction plate fixation, antegrade and retrograde raft screws fixations can increase the weight-bearing area, reduce the average stress and peak stress, and reduce the incidence of traumatic arthritis.
Outcome of Surgical Fixation of Lateral Column Distal Humerus Fractures.
Von Keudell, Arvind; Kachooei, Amir R; Moradi, Ali; Jupiter, Jesse B
2016-05-01
The purpose of this study was to report the long-term outcome and complications of surgically fixated lateral unicondylar distal humerus fractures. Retrospective Review. Two level 1 Trauma Centers, Massachusetts General Hospital and Brigham and Women's Hospital. Between 2002 and 2014, 24 patients treated with open reduction and internal fixation for lateral unicondylar distal humerus fractures (OTA/AO type B1 fractures) were retrospectively reviewed. Open reduction and internal fixation. Union rates, early complications, functional outcome, and the range of elbow motion were evaluated. Disabilities of the arm, shoulder, and hand, Mayo elbow Performance Index, satisfaction, pain scale, and American Shoulder and Elbow Surgeons. The mean age of patients was 46 ± 23 years at the time of surgery. The average final flexion/extension arc of motion was 108°. Reoperations were performed in 9 of 24 elbows after an average 21 ± 31 months. Twenty of the 24 patients were available for the clinical follow-up at an average of 70 months (range: 16-144 months). Disabilities of the arm, shoulder, and hand averaged at 10.8 ± 11.7 points, satisfaction at 9.5 ± 1.2, American Shoulder and Elbow Surgeons score at 88.5 ± 13.3 points at final follow-up. Based on the functional classification proposed by Jupiter, 16 demonstrated good to excellent results, 2 fair and 2 poor result. Outcome of open reduction and internal fixation of isolated lateral column distal humerus fractures can result in high union rates with acceptable outcome scores and high patient satisfaction despite a high reoperation rate. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Sod, Gary A; Riggs, Laura M; Mitchell, Colin F; Hubert, Jeremy D; Martin, George S
2010-01-01
To compare in vitro monotonic biomechanical properties of an axial 3-hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion (DCP-TLS) with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion (3-TLS) for the equine proximal interphalangeal (PIP) joint arthrodesis. Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. Cadaveric adult equine forelimbs (n=15 pairs). For each forelimb pair, 1 PIP joint was stabilized with an axial 3-hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion and 1 with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion. Five matching pairs of constructs were tested in single cycle to failure under axial compression, 5 construct pairs were tested for cyclic fatigue under axial compression, and 5 construct pairs were tested in single cycle to failure under torsional loading. Mean values for each fixation method were compared using a paired t-test within each group with statistical significance set at P<.05. Mean yield load, yield stiffness, and failure load under axial compression and torsion, single cycle to failure, of the DCP-TLS fixation were significantly greater than those of the 3-TLS fixation. Mean cycles to failure in axial compression of the DCP-TLS fixation was significantly greater than that of the 3-TLS fixation. The DCP-TLS was superior to the 3-TLS in resisting the static overload forces and in resisting cyclic fatigue. The results of this in vitro study may provide information to aid in the selection of a treatment modality for arthrodesis of the equine PIP joint.
Morin, Paul M; Reindl, Rudolf; Harvey, Edward J; Beckman, Lorne; Steffen, Thomas
2008-02-01
Distal third tibia fractures have classically been treated with standard plating, but intramedullary (IM) nailing has gained popularity. Owing to the lack of interference fit of the nail in the metaphyseal bone of the distal tibia, it may be beneficial to add rigid plating of the fibula to augment the overall stability of fracture fixation in this area. This study sought to assess the biomechanical effect of adding a fibular plate to standard IM nailing in the treatment of distal third tibia and fibula fractures. Eight cadaveric tibia specimens were used. Tibial fixation consisted of a solid titanium nail locked with 3 screws distally and 2 proximally, and fibular fixation consisted of a 3.5 mm low-contact dynamic compression plate. A section of tibia and fibula was removed. Testing was accomplished with an MTS machine. Each leg was tested 3 times; with and without a fibular plate and with a repetition of the initial test condition. Vertical displacements were tested with an axial load up to 500 N, and angular rotation was tested with torques up to 5 N*m. The difference in axial rotation was the only statistically significant finding (p = 0.003), with fibular fixation resulting in 1.1 degrees less rotation through the osteotomy site (17.96 degrees v. 19.10 degrees ). Over 35% of this rotational displacement occurred at the nail-locking bolt interface with the application of small torsional forces. Fibular plating in addition to tibial IM fixation of distal third tibia and fibula fractures leads to slightly increased resistance to torsional forces. This small improvement may not be clinically relevant.
Hirai, Masahiro; Muramatsu, Yukako; Mizuno, Seiji; Kurahashi, Naoko; Kurahashi, Hirokazu; Nakamura, Miho
2016-01-01
Evidence indicates that individuals with Williams syndrome (WS) exhibit atypical attentional characteristics when viewing faces. However, the dynamics of visual attention captured by faces remain unclear, especially when explicit attentional forces are present. To clarify this, we introduced a visual search paradigm and assessed how the relative strength of visual attention captured by a face and explicit attentional control changes as search progresses. Participants (WS and controls) searched for a target (butterfly) within an array of distractors, which sometimes contained an upright face. We analyzed reaction time and location of the first fixation-which reflect the attentional profile at the initial stage-and fixation durations. These features represent aspects of attention at later stages of visual search. The strength of visual attention captured by faces and explicit attentional control (toward the butterfly) was characterized by the frequency of first fixations on a face or butterfly and on the duration of face or butterfly fixations. Although reaction time was longer in all groups when faces were present, and visual attention was not dominated by faces in any group during the initial stages of the search, when faces were present, attention to faces dominated in the WS group during the later search stages. Furthermore, for the WS group, reaction time correlated with eye-movement measures at different stages of searching such that longer reaction times were associated with longer face-fixations, specifically at the initial stage of searching. Moreover, longer reaction times were associated with longer face-fixations at the later stages of searching, while shorter reaction times were associated with longer butterfly fixations. The relative strength of attention captured by faces in people with WS is not observed at the initial stage of searching but becomes dominant as the search progresses. Furthermore, although behavioral responses are associated with some aspects of eye movements, they are not as sensitive as eye-movement measurements themselves at detecting atypical attentional characteristics in people with WS.
Zuo, Chun-Guang; Liu, Xia-Jun; Wang, Xin-Hu; Wang, Jian-shun
2013-01-01
To discuss the therapeutic effects of the atlantoaxial pedicle screw system fixation in treatment of atlantoaxial instability. From June 2003 to March 2010, 32 patients with atlantoaxial instability were treated by atlantoaxial pedicle screw system fixation, included 21 males and 11 females wiht an average age of 42.5 years old ranging from 28 to 66 years. Among them, 18 cases were odontoid process fractures, 7 were congenital dissociate odontoid process, 4 were Jefferson fracture combined with odontoid fracture, 3 were rheumatic arthritis causing atlantoaxial instability. All patients suffered from the atlantoaxial subluxation and atlantoaxial instability. The JOA score ranged from 4 to 14 (means 9.1 +/- 0.3) before operation. The patients had some image examination including the X-ray of cervical vertebrae (include of dynamic position film), spiral CT 3D reconstruction and/or MRI. The position of pedicle screw system implantation,the angle of pedicle screw system implantation and screw length were measured. Operating skull traction. Operation undewent general anesthesia, implanted the pedicle screw, reduction and bone fusion under direct vision. The bone was fixated between posterior arch of atlas and lamina of axis by the lateral combination bended to posterior. One hundred and twenty-eight atlantoaxial pedicle screws were implanted in 32 patients. No patient had the injure of spinal cord, nerve root and vertebral artery. All patients were followed-up from 6 to 48 months (averaged 16 months). After operation, the JOA score ranged from 11 to 17 (averaged 15.9 +/- 0.2), improvement rate was 86.1%. The fracture of odontoid process were healing completely. All fusion bone were combinated. The internal fixation wasn't loosening and breaking. The atlantoaxial pedicle screw system fixation was effective method to treat atlantoaxial instability. The method had many advantages, such as provide rigid and short segment fixation, safe and simple, high fusion rate. The method was worth in clinical application.
Kim, Su-Young; Babar, Natasha; Munteanu, Emilia Laura; Takaoka, Anna; Zyablitskaya, Mariya; Nagasaki, Takayuki; Trokel, Stephen L; Paik, David C
2016-04-01
To develop methods to delineate the relationship between endothelial cell toxicity and tissue fixation (toxicity/fixation) using sodium hydroxymethylglycinate (SMG), a formaldehyde releaser, and riboflavin-UVA photochemical corneal cross-linking (CXL) for therapeutic tissue cross-linking of the cornea. Eleven fresh cadaveric rabbit heads were used for ex vivo corneal cross-linking simulation. After epithelial debridement, the tissue was exposed to 1/4 max (9.8 mM) or 1/3 max (13 mM) SMG at pH 8.5 for 30 minutes or riboflavin-UVA (CXL). The contralateral cornea served as a paired control. Postexposure, cross-linking efficacy was determined by thermal denaturation temperature (Tm) and endothelial damage was assessed using calcein AM and ethidium homodimer staining (The Live/Dead Kit). Confocal laser scanning fluorescence microscopy was used to generate live/dead cell counts using a standardized algorithm. The ΔTm after CXL, 1/3 SMG, and 1/4 SMG was 2.2 ± 0.9°C, 1.3 ± 0.5°C, and 1.1 ± 0.5°C, respectively. Endothelial cell damage was expressed as the percent of dead cells/live + dead cells counted per high-power field. The values were 3 ± 1.7% (control) and 8.9 ± 11.1% (CXL) (P = 0.390); 1 ± 0.2% (control) and 19.5 ± 32.2% (1/3 max SMG) (P = 0.426); and 2.7 ± 2.4% (control) and 2.8 ± 2.2% (1/4 max SMG) (P = 0.938). The values for endothelial toxicity were then indexed over the shift in Tm to yield a toxicity/fixation index. The values were as follows: 2.7 for CXL, 14 for 1/3 max, and 0.1 for 1/4 max. Quarter max (1/4 max = 9.8 mM) SMG effectively cross-linked tissue and was nontoxic to endothelial cells. Thus, SMG is potentially a compound that could achieve both desired effects.
Beaupre, Lauren A; Al-Houkail, Amro; Johnston, Donald William C
2016-06-01
Bearing surfaces in total hip arthroplasty (THA) may affect implant longevity and hence patient outcomes. This randomized clinical trial determined how ceramic-on-ceramic (CERAMIC) bearing THA affected joint-specific pain, function, and stiffness and prosthesis fixation/longevity over 10 postoperative years compared with ceramic-on-highly-crosslinked-polyethylene (POLYETHYLENE) bearing THA. This is a follow-up to previously reported 5-year outcomes. Subjects aged <61 years were randomized to CERAMIC (n = 48) or POLYETHYLENE (n = 44) THA. Subjects were assessed using the Western Ontario McMaster Osteoarthritis Index and the RAND 12-Item Health Survey preoperatively, and at 1, 5, and 10 years postoperatively. Plain radiographs were evaluated at 10 years for fixation, and medical records were reviewed for revisions. Of 92 subjects, 6 (7%) died within 10 years; 68 (79%) survivors provided radiographic and/or clinical follow-up at 10 years postoperatively. Improvements seen at 5 years in both the Western Ontario McMaster Osteoarthritis Index and RAND 12-Item Health Survey were retained at 10 years with no group differences (P > .48). There were no failures or loss of fixation related to bearing surfaces/wear in either group. Over 10 years, 3 subjects in the POLYETHYLENE group had revisions that were related to recurrent dislocation; 2 revisions were performed within 2 years of surgery, and one further subject underwent revision at 7 years postoperatively. This is one of the first randomized clinical trials to examine 10-year outcomes between CERAMIC and POLYETHYLENE bearing THAs. Both bearing surfaces performed well out to 10 years in subjects who were <61 years at time of surgery. Copyright © 2015 Elsevier Inc. All rights reserved.
Minimally invasive reconstruction of acute type IV and Type V acromioclavicular separations.
Katsenis, Dimitris L; Stamoulis, Dimitris; Begkas, Dimitris; Tsamados, Stamatis
2015-04-01
The goal of this study was to evaluate the midterm radiologic, clinical, and functional results of the early reconstruction of the severe acromioclavicular joint dislocation using the flipptack fixation button technique. Between December 2006 and December 2009, one hundred thirty-five consecutive patients with acromioclavicular joint separations were admitted to the authors' institution. Fifty patients were included in the study. According to Rockwood classification, 29 (58%) dislocations were type IV and 21 (42%) were type V. Surgery was performed at an average of 4.2 days (range, 0-12 days) after dislocation. All dislocations were treated with the flipptack fixation button technique. All patients were evaluated at a final postoperative follow-up of 42 months (range, 36-49 months). The clinical outcome was assessed using the Constant score. The functional limitation was assessed using the bother index of the short Musculoskeletal Function Assessment. Radiographs taken immediately postoperatively and at the final follow-up assessed acromioclavicular joint reduction, coracoclavicular distance, and joint arthrosis. At the final follow-up, mean Constant score was 93.04 (range, 84-100). The average (±SD) short Musculoskeletal Function Assessment bother index was 20.88±8.95 (range, 2.0-49). No statistically significant difference was found between the acromioclavicular joint dislocation type and the clinical result (P=.227; chi-square, 6.910, Kruskal Wallis test). The regression of the coracoclavicular distance at final follow-up was not statistically significant (P=.276; chi-square, 6.319, Kruskal Wallis test). The flipptack fixation button technique is an effective alternative for the treatment of severe acromioclavicular joint dislocation. Because all objectives of the treatment were obtained, the results do not deteriorate over time. Copyright 2015, SLACK Incorporated.
Griffin, Xavier L; Achten, Juul; Sones, William; Cook, Jonathan; Costa, Matthew L
2018-01-26
Sliding hip screw fixation is well established in the treatment of trochanteric fractures of the hip. The X-Bolt Dynamic Hip Plating System builds on the successful design features of the sliding hip screw but differs in the nature of the fixation in the femoral head. A randomised pilot study suggested that the X-bolt Dynamic Hip Plating System might provide similar health-related quality of life while reducing the risk of revision surgery when compared with the sliding hip screw. This is the protocol for a multicentre randomised trial of sliding hip screw versus X-Bolt Dynamic Hip Plating System for patients 60 years and over treated for a trochanteric fracture of the hip. Multicentre, multisurgeon, parallel, two-arm, randomised controlled trial. Patients aged 60 years and older with a trochanteric hip fracture are potentially eligible. Participants will be randomly allocated on a 1:1 basis to either sliding hip screw or X-Bolt Dynamic Hip Plating System. Otherwise, all care will be in accordance with National Institute for Health and Care Excellence guidance. A minimum of 1128 patients will be recruited to obtain 90% power to detect a 0.075-point difference in EuroQol-5D health-related quality of life at 4 months postrandomisation. Secondary outcomes include mortality, residential status, revision surgery and radiographic measures. The treatment effect will be estimated using a two-sided t-test adjusted for age, gender and cognitive impairment based on an intention-to-treat analysis. National Research Ethics Committee approved this study on 5 February 2016 (16/WM/0001). The study is sponsored by the University of Oxford and funded through an investigator initiated grant by X-Bolt Orthopaedics. A manuscript for a high-impact peer-reviewed journal will be prepared, and the results will be disseminated to patients through local mechanisms at participating centres. ISRCTN92825709. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Anterior inferior plating versus superior plating for clavicle fracture: a meta-analysis.
Ai, Jie; Kan, Shun-Li; Li, Hai-Liang; Xu, Hong; Liu, Yang; Ning, Guang-Zhi; Feng, Shi-Qing
2017-04-18
The position of plate fixation for clavicle fracture remains controversial. Our objective was to perform a comprehensive review of the literature and quantify the surgical parameters and clinical indexes between the anterior inferior plating and superior plating for clavicle fracture. PubMed, EMBASE, and the Cochrane Library were searched for randomized and non-randomized studies that compared the anterior inferior plating with the superior plating for clavicle fracture. The relative risk or standardized mean difference with 95% confidence interval was calculated using either a fixed- or random-effects model. Four randomized controlled trials and eight observational studies were identified to compare the surgical parameters and clinical indexes. For the surgical parameters, the anterior inferior plating group was better than the superior plating group in operation time and blood loss (P < 0.05). Furthermore, in terms of clinical indexes, the anterior inferior plating was superior to the superior plating in reducing the union time, and the two kinds of plate fixation methods were comparable in constant score, and the rate of infection, nonunion, and complications (P > 0.05). Based on the current evidence, the anterior inferior plating may reduce the blood loss, the operation and union time, but no differences were observed in constant score, and the rate of infection, nonunion, and complications between the two groups. Given that some of the studies have low quality, more randomized controlled trails with high quality should be conduct to further verify the findings.
Benahmed, N; De Wever, A; Pirson, M
2017-01-01
The last few years have seen major changes in the Belgian medical planning. The paper aims to describe them and to assess how they will affect the medical demography. Grey literature review and federal and federated entities legislation summary. A new dynamic register allows a better knowledge of medical workforce in all sectors of labour market. Recent legislation evolutions induce fragmentation of competences related to human resource for health planning : federal authorities are responsive for the fixation of number of GP and specialists and community authorities for registration of health professionals and fixation of sub-quotas in different branches of specialised medicine. Finally, the French Community has setting up a multiple selection system of medical students that have to past an 'orientation test', a possible reorientation after January examinations and then a numerus fixus at the end of the first academic year. Dynamic register improves the knowledge of medical workforce repartition. However, the assessment of its volume shows methodological limitations. From an operational viewpoint, the fragmentation of competences will ask coordination effort from all authority levels to avoid impairment in planning process. Finally, French Community has to consider evaluation and ambitious revision of medical workforce planning in their region.
The Temporal Dynamics of Coastal Phytoplankton and Bacterioplankton in the Eastern Mediterranean Sea
Raveh, Ofrat; David, Niv; Rilov, Gil; Rahav, Eyal
2015-01-01
This study considers variability in phytoplankton and heterotrophic bacterial abundances and production rates, in one of the most oligotrophic marine regions in the world–the Levantine Basin. The temporal dynamics of these planktonic groups were studied in the coastal waters of the southeastern Mediterranean Sea approximately every two weeks for a total of two years. Heterotrophic bacteria were abundant mostly during late summer and midwinter, and were positively correlated with bacterial production and with N2 fixation. Based on size fractionating, picophytoplankton was abundant during the summer, whereas nano-microphytoplankton predominated during the winter and early spring, which were also evident in the size-fractionated primary production rates. Autotrophic abundance and production correlated negatively with temperature, but did not correlate with inorganic nutrients. Furthermore, a comparison of our results with results from the open Levantine Basin demonstrates that autotrophic and heterotrophic production, as well as N2 fixation rates, are considerably higher in the coastal habitat than in the open sea, while nutrient levels or cell abundance are not different. These findings have important ecological implications for food web dynamics and for biological carbon sequestration in this understudied region. PMID:26474399
Impact of Trichodesmium Sp. on Pacific Primary production
NASA Astrophysics Data System (ADS)
Dutheil, C.; Menkes, C.; Aumont, O.; Shiozaki, T.; Bonnet, S.; Rodier, M.; Bopp, L.; Lorrain, A.
2016-12-01
Recent sea-experiments have suggested that the South Pacific is one of the world's hot spot for nitrogen fixation. In that region, diazotrophs Trichodesmium Sp. have been shown to be one of its major contributors. Here we assess the climatological impact of these diazotrophs in the Pacific by using a 1°x1° coupled model dynamical-biogeochemical model ROMS-PISCES in which an explicit a Trichodesmium compartment is implemented. Firstly, we validate our model on the main limiting components (phosphate, iron, and temperature) of Trichodesmium growth. Phosphate patterns show modelled values and structures in qualitatively good agreement with observations. Iron concentrations are in good agreement with the observations. We also validate our model on nitrogen fixation rates. The regional spatial patterns of strong fixation are coherent with the observations. In the South Pacific, the model is able to reproduce the strong east-west gradient. Secondly, we evaluate the climatological effects of Trichodesmium on the biogeochemical conditions of the Tropical Pacific by adding with the explicit Trichodesmium compartment. The implementation of this compartment improves the model ability to reproduce the observed chlorophyll fields in the South West Pacific and the northern hemisphere, especially around Hawaii. In regions where there are strong nitrogen fixation rates, we observe an increase in the primary production by more than 100%, and an increase by more than 60 % in the production due to nanophytoplankton and diatoms, between the simulation with trichodesmium and without nitrogen fixation.
2017-12-01
reverse dynamization. This was supplemented by finite element analysis and the use of a strain gauge. This aim was successfully completed, with the...testing deformation results for model validation. Development of a Finite Element (FE) model was conducted through ANSYS 16 to help characterize...Fixators were characterized through mechanical testing by sawbone and ovine cadaver tibiae samples, and data was used to validate a finite element
Lu, Tiegang; Zhang, Zhiguo
2017-01-01
Plant leaves exhibit differentiated patterns of photosynthesis rates under diurnal light regulation. Maize leaves show a single-peak pattern without photoinhibition at midday when the light intensity is maximized. This mechanism contributes to highly efficient photosynthesis in maize leaves. To understand the molecular basis of this process, an isobaric tag for relative and absolute quantitation (iTRAQ)-based proteomics analysis was performed to reveal the dynamic pattern of proteins related to photosynthetic reactions. Steady, single-peak and double-peak protein expression patterns were discovered in maize leaves, and antenna proteins in these leaves displayed a steady pattern. In contrast, the photosystem, carbon fixation and citrate pathways were highly controlled by diurnal light intensity. Most enzymes in the limiting steps of these pathways were major sites of regulation. Thus, maize leaves optimize photosynthesis and carbon fixation outside of light harvesting to adapt to the changes in diurnal light intensity at the protein level. PMID:28732011
[Dynamic forces of Mitkovic self-dinamysible trochanteric Internal fixators (SIF)].
Mitković, Milan M; Manić, Miodrag T; Petković, Dusan Lj; Milenković, Sasa S; Mitković, Milorad B
2013-01-01
Dynamic trochanteric fractures implants allow fracture fragments to be compressed. Dynamisation can be realized if the axial pin force overcome friction force between pin and body of the implant. Examination of sliding iniciation forces in Mitkovic Selfdinamysible Trochanteric Internal Fixator (SIF). SIF was attached for angle block in the position with vertical orientation of pins. The transversal load of 5 kg was connected to pins by a rope. A dynamometer was used to measure force during the movement of angle block in up direction. Regression coefficients were a1 = 4,052 i b1 = 0,623 for SIF with 2 sliding screws with diameter of 7mm and a2 = 4,534 i b2 = 0,422 for SIF with 1 screw with diameter of 10 mm. Coefficients of determination were: r12 = 0,470 and r22 = 0,123. Sliding of SIF pins can be achieved for each analysed body weight of patient (50-130 kg). Early bearing of operated leg is significant for sliding initiation of SIF sliding screws.
Large Extremity Peripheral Nerve Repair
2013-10-01
show that the PTB method can provide fixation strengths approaching that of conventional microsurgery and that the PTB repair is unlikely to be...biomaterial during long periods of recovery associated with large nerve deficit reconstruction and long nerve grafts. As with the human amnion nerve...functional recovery model (SFI, sciatic function index) using PTB/xHAM wrap compared to standard (suture) of care microsurgery . Demonstrated improved nerve
Sakaura, Hironobu; Miwa, Toshitada; Yamashita, Tomoya; Kuroda, Yusuke; Ohwada, Tetsuo
2018-01-01
OBJECTIVE The cortical bone trajectory (CBT) screw technique is a new nontraditional pedicle screw (PS) insertion method. However, the biomechanical behavior of multilevel CBT screw/rod fixation remains unclear, and surgical outcomes in patients after 2-level posterior lumbar interbody fusion (PLIF) using CBT screw fixation have not been reported. Thus, the purposes of this study were to examine the clinical and radiological outcomes after 2-level PLIF using CBT screw fixation for 2-level degenerative lumbar spondylolisthesis (DS) and to compare these outcomes with those after 2-level PLIF using traditional PS fixation. METHODS The study included 22 consecutively treated patients who underwent 2-level PLIF with CBT screw fixation for 2-level DS (CBT group, mean follow-up 39 months) and a historical control group of 20 consecutively treated patients who underwent 2-level PLIF using traditional PS fixation for 2-level DS (PS group, mean follow-up 35 months). Clinical symptoms were evaluated using the Japanese Orthopaedic Association (JOA) scoring system. Bony union was assessed by dynamic plain radiographs and CT images. Surgery-related complications, including symptomatic adjacent-segment disease (ASD), were examined. RESULTS The mean operative duration and intraoperative blood loss were 192 minutes and 495 ml in the CBT group and 218 minutes and 612 ml in the PS group, respectively (p < 0.05 and p > 0.05, respectively). The mean JOA score improved significantly from 12.3 points before surgery to 21.1 points (mean recovery rate 54.4%) at the latest follow-up in the CBT group and from 12.8 points before surgery to 20.4 points (mean recovery rate 51.8%) at the latest follow-up in the PS group (p > 0.05). Solid bony union was achieved at 90.9% of segments in the CBT group and 95.0% of segments in the PS group (p > 0.05). Symptomatic ASD developed in 2 patients in the CBT group (9.1%) and 4 patients in the PS group (20.0%, p > 0.05). CONCLUSIONS Two-level PLIF with CBT screw fixation for 2-level DS could be less invasive and result in improvement of clinical symptoms equal to those of 2-level PLIF using traditional PS fixation. The incidence of symptomatic ASD and the rate of bony union were lower in the CBT group than in the PS group, although these differences were not significant.
Lehner, Rea; Balsters, Joshua H; Bürgler, Alexandra; Hare, Todd A; Wenderoth, Nicole
2017-01-01
Obese individuals have been shown to exhibit abnormal sensitivity to rewards and reward-predicting cues as for example food-associated cues frequently used in advertisements. It has also been shown that food-associated cues can increase goal-directed behavior but it is currently unknown, whether this effect differs between normal-weight, overweight, and obese individuals. Here, we investigate this question by using a Pavlovian-to-instrumental transfer (PIT) task in normal-weight ( N = 20), overweight ( N = 17), and obese ( N = 17) individuals. Furthermore, we applied eye tracking during Pavlovian conditioning to measure the participants' conditioned response as a proxy of the incentive salience of the predicted reward. Our results show that the goal-directed behavior of overweight individuals was more strongly influenced by food-predicting cues (i.e., stronger PIT effect) than that of normal-weight and obese individuals ( p < 0.001). The weight groups were matched for age, gender, education, and parental education. Eye movements during Pavlovian conditioning also differed between weight categories ( p < 0.05) and were used to categorize individuals based on their fixation style into "high eye index" versus "low eye index" as well. Our main finding was that the fixation style exhibited a complex interaction with the weight category. Furthermore, we found that normal-weight individuals of the group "high eye index" had higher body mass index within the healthy range than individuals of the group "low eye index" ( p < 0.001), but this relationship was not found within in the overweight or obese groups ( p > 0.646). Our findings are largely consistent with the incentive sensitization theory predicting that overweight individuals are more susceptible to food-related cues than normal-weight controls. However, this hypersensitivity might be reduced in obese individuals, possibly due to habitual/compulsive overeating or differences in reward valuation.
Assessment of Attentional Workload while Driving by Eye-fixation-related Potentials
NASA Astrophysics Data System (ADS)
Takeda, Yuji; Yoshitsugu, Noritoshi; Itoh, Kazuya; Kanamori, Nobuhiro
How do drivers cope with the attentional workload of in-vehicle information technology? In the present study, we propose a new psychophysiological measure for assessing drivers' attention: eye-fixation-related potential (EFRP). EFRP is a kind of event-related brain potential measurable at the eye-movement situation that reflects how closely observers examine visual information at the eye-fixated position. In the experiment, the effects of verbal working memory load and spatial working memory load during simulated driving were examined by measuring the number of saccadic eye-movements and EFRP as the indices of drivers' attention. The results showed that the spatial working memory load affected both the number of saccadic eye-movements and the amplitude of the P100 component of EFRP, whereas the verbal working memory load affected only the number of saccadic eye-movements. This implies that drivers can perform time-sharing processing between driving and the verbal working memory task, but the decline of accuracy of visual processing during driving is inescapable when the spatial working memory load is given. The present study suggests that EFRP can provide a new index of drivers' attention, other than saccadic eye-movements.
Femoral neck shortening after internal fixation of a femoral neck fracture.
Zielinski, Stephanie M; Keijsers, Noël L; Praet, Stephan F E; Heetveld, Martin J; Bhandari, Mohit; Wilssens, Jean Pierre; Patka, Peter; Van Lieshout, Esther M M
2013-07-01
This study assesses femoral neck shortening and its effect on gait pattern and muscle strength in patients with femoral neck fractures treated with internal fixation. Seventy-six patients from a multicenter randomized controlled trial participated. Patient characteristics and Short Form 12 and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores were collected. Femoral neck shortening, gait parameters, and maximum isometric forces of the hip muscles were measured and differences between the fractured and contralateral leg were calculated. Variables of patients with little or no shortening, moderate shortening, and severe shortening were compared using univariate and multivariate analyses. Median femoral neck shortening was 1.1 cm. Subtle changes in gait pattern, reduced gait velocity, and reduced abductor muscle strength were observed. Age, weight, and Pauwels classification were risk factors for femoral neck shortening. Femoral neck shortening decreased gait velocity and seemed to impair gait symmetry and physical functioning. In conclusion, internal fixation of femoral neck fractures results in permanent physical limitations. The relatively young and healthy patients in our study seem capable of compensating. Attention should be paid to femoral neck shortening and proper correction with a heel lift, as inadequate correction may cause physical complaints and influence outcome. Copyright 2013, SLACK Incorporated.
Attentional processing of other's facial display of pain: an eye tracking study.
Vervoort, Tine; Trost, Zina; Prkachin, Kenneth M; Mueller, Sven C
2013-06-01
The present study investigated the role of observer pain catastrophizing and personal pain experience as possible moderators of attention to varying levels of facial pain expression in others. Eye movements were recorded as a direct and continuous index of attention allocation in a sample of 35 undergraduate students while viewing slides presenting picture pairs consisting of a neutral face combined with either a low, moderate, or high expressive pain face. Initial orienting of attention was measured as latency and duration of first fixation to 1 of 2 target images (i.e., neutral face vs pain face). Attentional maintenance was measured by gaze duration. With respect to initial orienting to pain, findings indicated that participants reporting low catastrophizing directed their attention more quickly to pain faces than to neutral faces, with fixation becoming increasingly faster with increasing levels of facial pain expression. In comparison, participants reporting high levels of catastrophizing showed decreased tendency to initially orient to pain faces, fixating equally quickly on neutral and pain faces. Duration of the first fixation revealed no significant effects. With respect to attentional maintenance, participants reporting high catastrophizing and pain intensity demonstrated significantly longer gaze duration for all face types (neutral and pain expression), relative to low catastrophizing counterparts. Finally, independent of catastrophizing, higher reported pain intensity contributed to decreased attentional maintenance to pain faces vs neutral faces. Theoretical implications and further research directions are discussed. Copyright © 2013 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.
Ruan, Hongjiang; Zhu, Yi; Liu, Shen; Kang, Qinglin
2018-05-01
Several humeral lengthening or simultaneous deformity corrections through one osteotomy using various external fixators were reported, while literature regarding correction of shortening and proximal varus deformity is scarce. This retrospective clinical study evaluated the results of preforming an acute correction and delayed lengthening in young adults through two osteotomies using monorail external fixator. We report seven patients with various pathologies who underwent humeral proximal deformity correction and lengthening between 2009 and 2015. Pre-operative and post-operative clinical and radiographic data were collected. The mean follow-up time was 33.4 months (25-46 months). The humeral neck-shaft angle improved from 97.9° (85-110°) to 138.6° (135-145°). The magnitude of lengthening achieved was average 7.6 cm (range, 6-10 cm) at an average healing index of lengthening of 30.2 days/cm (range, 27.7-35.4 days/cm). There was a significant increase in range of shoulder abduction, and active abduction improved from pre-operative 136.4° (range, 95-160°) to post-operative 166.4° (range, 150-180°). The DASH score improved significance from 23.29 ± 8.36 to 6.57 ± 3.65 (t = 4.848; p < 0.001). Acute deformity correction and gradual lengthening with the monorail external fixator can be used for humeral shortening and proximal varus angular deformity. Functional improvement is expected after surgery and post-operative therapy.
Hybrid Instrumentation in Lumbar Spinal Fusion
Danyali, Reza; Kueny, Rebecca; Huber, Gerd; Reichl, Michael; Richter, Alexander; Niemeyer, Thomas; Morlock, Michael; Püschel, Klaus; Übeyli, Hüseyin
2017-01-01
Study Design Ex vivo human cadaveric study. Objective The development or progression of adjacent segment disease (ASD) after spine stabilization and fusion is a major problem in spine surgery. Apart from optimal balancing of the sagittal profile, dynamic instrumentation is often suggested to prevent or impede ASD. Hybrid instrumentation is used to gain stabilization while allowing motion to avoid hypermobility in the adjacent segment. In this biomechanical study, the effects of two different hybrid instrumentations on human cadaver spines were evaluated and compared with a rigid instrumentation. Methods Eighteen human cadaver spines (T11–L5) were subdivided into three groups: rigid, dynamic, and hook comprising six spines each. Clinical parameters and initial mechanical characteristics were consistent among groups. All specimens received rigid fixation from L3–L5 followed by application of a free bending load of extension and flexion. The range of motion (ROM) for every segment was evaluated. For the rigid group, further rigid fixation from L1–L5 was applied. A dynamic Elaspine system (Spinelab AG, Winterthur, Switzerland) was applied from L1 to L3 for the dynamic group, and the hook group was instrumented with additional laminar hooks at L1–L3. ROM was then evaluated again. Results There was no significant difference in ROM among the three instrumentation techniques. Conclusion Based on this data, the intended advantage of a hybrid or dynamic instrumentation might not be achieved. PMID:28451509
Sternick, Marcelo Back; Dallacosta, Darlan; Bento, Daniela Águida; do Reis, Marcelo Lemos
2015-01-01
Objective: To analyze the rigidity of a platform-type external fixator assembly, according to different numbers of pins on each clamp. Methods: Computer simulation on a large-sized Cromus dynamic external fixator (Baumer SA) was performed using a finite element method, in accordance with the standard ASTM F1541. The models were generated with approximately 450,000 quadratic tetrahedral elements. Assemblies with two, three and four Schanz pins of 5.5 mm in diameter in each clamp were compared. Every model was subjected to a maximum force of 200 N, divided into 10 sub-steps. For the components, the behavior of the material was assumed to be linear, elastic, isotropic and homogeneous. For each model, the rigidity of the assembly and the Von Mises stress distribution were evaluated. Results: The rigidity of the system was 307.6 N/mm for two pins, 369.0 N/mm for three and 437.9 N/mm for four. Conclusion: The results showed that four Schanz pins in each clamp promoted rigidity that was 19% greater than in the configuration with three pins and 42% greater than with two pins. Higher tension occurred in configurations with fewer pins. In the models analyzed, the maximum tension occurred on the surface of the pin, close to the fixation area. PMID:27047879
Buchan, Julie N; Paré, Martin; Munhall, Kevin G
2008-11-25
During face-to-face conversation the face provides auditory and visual linguistic information, and also conveys information about the identity of the speaker. This study investigated behavioral strategies involved in gathering visual information while watching talking faces. The effects of varying talker identity and varying the intelligibility of speech (by adding acoustic noise) on gaze behavior were measured with an eyetracker. Varying the intelligibility of the speech by adding noise had a noticeable effect on the location and duration of fixations. When noise was present subjects adopted a vantage point that was more centralized on the face by reducing the frequency of the fixations on the eyes and mouth and lengthening the duration of their gaze fixations on the nose and mouth. Varying talker identity resulted in a more modest change in gaze behavior that was modulated by the intelligibility of the speech. Although subjects generally used similar strategies to extract visual information in both talker variability conditions, when noise was absent there were more fixations on the mouth when viewing a different talker every trial as opposed to the same talker every trial. These findings provide a useful baseline for studies examining gaze behavior during audiovisual speech perception and perception of dynamic faces.
Fixation probabilities of evolutionary coordination games on two coupled populations
NASA Astrophysics Data System (ADS)
Zhang, Liye; Ying, Limin; Zhou, Jie; Guan, Shuguang; Zou, Yong
2016-09-01
Evolutionary forces resulted from competitions between different populations are common, which change the evolutionary behavior of a single population. In an isolated population of coordination games of two strategies (e.g., s1 and s2), the previous studies focused on determining the fixation probability that the system is occupied by only one strategy (s1) and their expectation times, given an initial mixture of two strategies. In this work, we propose a model of two interdependent populations, disclosing the effects of the interaction strength on fixation probabilities. In the well-mixing limit, a detailed linear stability analysis is performed, which allows us to find and to classify the different equilibria, yielding a clear picture of the bifurcation patterns in phase space. We demonstrate that the interactions between populations crucially alter the dynamic behavior. More specifically, if the coupling strength is larger than some threshold value, the critical initial density of one strategy (s1) that corresponds to fixation is significantly delayed. Instead, the two populations evolve to the opposite state of all (s2) strategy, which are in favor of the red queen hypothesis. We delineate the extinction time of strategy (s1) explicitly, which is an exponential form. These results are validated by systematic numerical simulations.
An indigenous method for closed reduction of pediatric mandibular parasymphysis fracture.
Kumar, Naresh; Singh, Akhilesh Kumar; Pandey, Arun; Verma, Vishal
2015-01-01
Mandibular fractures in children are very rare as compared to adults due to protected anatomic features of child and less exposure to road traffic accidents. Management becomes complicated due to inherent dynamic nature, instability of mixed dentition and fear of surgery. Conservative management can be done with the help of acrylic cap splints along with circum-mandibular wiring, intermaxillary fixation with eyelet wires, arch wires or open reduction and internal fixation with bio-resorbable plates. Different methods have various pros and cons. The choice of anesthesia is also very crucial sometimes. This case report describes a new method of closed reduction with 18 gauge needle simulated as an arch bar performed under local anaesthesia.
An indigenous method for closed reduction of pediatric mandibular parasymphysis fracture
Kumar, Naresh; Singh, Akhilesh Kumar; Pandey, Arun; Verma, Vishal
2015-01-01
Mandibular fractures in children are very rare as compared to adults due to protected anatomic features of child and less exposure to road traffic accidents. Management becomes complicated due to inherent dynamic nature, instability of mixed dentition and fear of surgery. Conservative management can be done with the help of acrylic cap splints along with circum-mandibular wiring, intermaxillary fixation with eyelet wires, arch wires or open reduction and internal fixation with bio-resorbable plates. Different methods have various pros and cons. The choice of anesthesia is also very crucial sometimes. This case report describes a new method of closed reduction with 18 gauge needle simulated as an arch bar performed under local anaesthesia. PMID:27390498
The use of intramedullary nails in tibiotalocalcaneal arthrodesis.
Thomas, Ruth L; Sathe, Vinayak; Habib, Syed I
2012-01-01
Tibiotalocalcaneal arthrodesis is a salvage procedure undertaken for hindfoot problems that affect both the ankle and subtalar joints (eg, two-joint arthritis, severe acute trauma, osteonecrosis of the talus, severe malalignment deformities, significant hindfoot bone loss). Methods of achieving fusion include Steinmann pins, screws, plates, external fixators, and retrograde intramedullary nailing. Retrograde intramedullary nailing provides a load-sharing fixation device with superior biomechanical properties and is an excellent choice for use in tibiotalocalcaneal arthrodesis. This technique can be performed through relatively small incisions. In addition, recent design modifications include the availability of dynamization and the choice of curved or straight nails. Contraindications to the technique include the presence of infection, severe vascular disease, and severe malalignment of the tibia.
Dorsal Plating of Unstable Scaphoid Fractures and Nonunions.
Bain, Gregory I; Turow, Arthur; Phadnis, Joideep
2015-09-01
Achieving stable fixation of displaced acute and chronic nonunited scaphoid fractures continues to be a challenge for the treating surgeon. The threaded compression screw has been the mainstay of treatment of these fractures for the last 3 decades; however, persistent nonunion after screw fixation has prompted development of new techniques. Recent results of volar buttress plating have been promising. We describe a novel technique of dorsal scaphoid plating. In contrast to volar plating, the dorsal plate is biomechanically more favorable as it utilizes the tension side of the scaphoid bone for dynamic compression. Dorsal scaphoid plating provides a more stable construct than the traditional Herbert screw and mitigates the need for vascular or corticocancellous bone grafting in most cases.
Face processing in autism: Reduced integration of cross-feature dynamics.
Shah, Punit; Bird, Geoffrey; Cook, Richard
2016-02-01
Characteristic problems with social interaction have prompted considerable interest in the face processing of individuals with Autism Spectrum Disorder (ASD). Studies suggest that reduced integration of information from disparate facial regions likely contributes to difficulties recognizing static faces in this population. Recent work also indicates that observers with ASD have problems using patterns of facial motion to judge identity and gender, and may be less able to derive global motion percepts. These findings raise the possibility that feature integration deficits also impact the perception of moving faces. To test this hypothesis, we examined whether observers with ASD exhibit susceptibility to a new dynamic face illusion, thought to index integration of moving facial features. When typical observers view eye-opening and -closing in the presence of asynchronous mouth-opening and -closing, the concurrent mouth movements induce a strong illusory slowing of the eye transitions. However, we find that observers with ASD are not susceptible to this illusion, suggestive of weaker integration of cross-feature dynamics. Nevertheless, observers with ASD and typical controls were equally able to detect the physical differences between comparison eye transitions. Importantly, this confirms that observers with ASD were able to fixate the eye-region, indicating that the striking group difference has a perceptual, not attentional origin. The clarity of the present results contrasts starkly with the modest effect sizes and equivocal findings seen throughout the literature on static face perception in ASD. We speculate that differences in the perception of facial motion may be a more reliable feature of this condition. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Students as Threats: Schooling inside a Youth Prison
ERIC Educational Resources Information Center
Vélez Young-Alfaro, Morghan
2017-01-01
This ethnography explores incarcerated students' experiences and dynamics of identity formation inside a youth prison school. Across two years, 100 students and 50 adults were engaged. The structure, discourse, and adult-student interactions revealed a fixation on framing students as threats with a racialized undertone while also exposing the…
Hinde, Stephen J; Smith, Tim J; Gilchrist, Iain D
2017-05-01
In the laboratory, the abrupt onset of a visual distractor can generate an involuntary orienting response: this robust oculomotor capture effect has been reported in a large number of studies (e.g. Ludwig & Gilchrist, 2002; Theeuwes, Kramer, Hahn, & Irwin, 1998) suggesting it may be a ubiquitous part of more natural visual behaviour. However the visual stimuli used in these experiments have tended to be static and had none of the complexity, and dynamism of more natural visual environments. In addition, the primary task in the laboratory (typically visual search) can be tedious for the participants with participant's losing interest and becoming stimulus driven and more easily distracted. Both of these factors may have led to an overestimation of the extent to which oculomotor capture occurs and the importance of this phenomena in everyday visual behaviour. To address this issue, in the current series of studies we presented abrupt and highly salient visual distractors away from fixation while participants watched a film. No evidence of oculomotor capture was found. However, the distractor does effect fixation duration: we find an increase in fixation duration analogous to the remote distractor effect (Walker, Deubel, Schneider, & Findlay, 1997). These results suggest that during dynamic scene perception, the oculomotor system may be under far more top-down control than traditional laboratory based-tasks have previously suggested. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
Brown, Bryan D; Steinert, Justin N; Stelzer, John W; Yoon, Richard S; Langford, Joshua R; Koval, Kenneth J
2017-12-01
Indications for removing orthopedic hardware on an elective basis varies widely. Although viewed as a relatively benign procedure, there is a lack of data regarding overall complication rates after fracture fixation. The purpose of this study is to determine the overall short-term complication rate for elective removal of orthopedic hardware after fracture fixation and to identify associated risk factors. Adult patients indicated for elective hardware removal after fracture fixation between July 2012 and July 2016 were screened for inclusion. Inclusion criteria included patients with hardware related pain and/or impaired cosmesis with complete medical and radiographic records and at least 3-month follow-up. Exclusion criteria were those patients indicated for hardware removal for a diagnosis of malunion, non-union, and/or infection. Data collected included patient age, gender, anatomic location of hardware removed, body mass index, ASA score, and comorbidities. Overall complications, as well as complications requiring revision surgery were recorded. Statistical analysis was performed with SPSS 20.0, and included univariate and multivariate regression analysis. 391 patients (418 procedures) were included for analysis. Overall complication rates were 8.4%, with a 3.6% revision surgery rate. Univariate regression analysis revealed that patients who had liver disease were at significant risk for complication (p=0.001) and revision surgery (p=0.036). Multivariate regression analysis showed that: 1) patients who had liver disease were at significant risk of overall complication (p=0.001) and revision surgery (p=0.039); 2) Removal of hardware following fixation for a pilon had significantly increased risk for complication (p=0.012), but not revision surgery (p=0.43); and 3) Removal of hardware for pelvic fixation had a significantly increased risk for revision surgery (p=0.017). Removal of hardware following fracture fixation is not a risk-free procedure. Patients with liver disease are at increased risk for complications, including increased risk for needing revision surgery following hardware removal. Patients having hardware removed following fixation for pilon fractures also are at increased risk for complication, although they may not require a return trip to the operating room. Finally, removal of pelvic hardware is associated with a higher return to the operating room. Copyright © 2017 Elsevier Ltd. All rights reserved.
Mao, Ke-ya; Wang, Yan; Xiao, Song-hua; Zhang, Yong-gang; Liu, Bao-wei; Wang, Zheng; Zhang, Xi-Feng; Cui, Geng; Zhang, Xue-song; Li, Peng; Mao, Ke-zheng
2013-08-01
To investigate the feasibility of minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) using hybrid internal fixation of pedicle screws and a translaminar facet screw for recurrent lumbar disc herniation. From January 2010 to December 2011, 16 recurrent lumbar disc herniation patients, 10 male and 6 female patients with an average age of 45 years (35-68 years) were treated with unilateral incision MIS-TLIF through working channel. After decompression, interbody fusion and fixation using unilateral pedicle screws, a translaminar facet screw was inserted from the same incision through spinous process and laminar to the other side facet joint. The results of perioperative parameters, radiographic images and clinical outcomes were assessed. The repeated measure analysis of variance was applied in the scores of visual analogue scale (VAS) and Oswestry disablity index (ODI). All patients MIS-TLIF were accomplished under working channel including decompression, interbody fusion and hybrid fixation without any neural complication. The average operative time was (148 ± 75) minutes, the average operative blood loss was (186 ± 226) ml, the average postoperative ambulation time was (32 ± 15) hours, and the average hospitalization time was (6 ± 4) days. The average length of incision was (29 ± 4) mm, and the average length of translaminar facets screw was (52 ± 6) mm. The mean follow-up was 16.5 months with a range of 12-24 months. The postoperative X-ray and CT images showed good position of the hybrid internal fixation, and all facets screws penetrate through facets joint. The significant improvement could be found in back pain VAS, leg pain VAS and ODI scores between preoperative 1 day and postoperative follow-up at all time-points (back pain VAS:F = 52.845, P = 0.000;leg pain VAS:F = 113.480, P = 0.000;ODI:F = 36.665, P = 0.000). Recurrent lumbar disc herniation could be treated with MIS-TLIF using hybrid fixation through unilateral incision, and the advantage including less invasion and quickly recovery.
Achten, Juul; Parsons, Nicholas R; McGuinness, Katie R; Petrou, Stavros; Lamb, Sarah E; Costa, Matthew L
2015-01-01
Introduction The treatment of displaced, extra-articular fractures of the distal tibia remains controversial. These injuries are difficult to manage due to limited soft tissue cover, poor vascularity of the area and proximity to the ankle joint. Surgical treatment options are expanding and include locked intramedullary nails, plate and screw fixation and external fixator systems. The nail and plate options are most commonly used in the UK, but controversy exists over which treatment is most clinically and cost-effective. In this multicentre randomised controlled trial we aim to assess ratings of disability 6 months postinjury in patients who have sustained a distal tibia fracture treated with either an intramedullary nail or plate and locking screw fixation. Methods and analysis Adult patients presenting at trial centres with an acute fracture of the distal tibia will be considered for inclusion. A total of 320 patients will provide 90% power to detect a difference of 8 points in Disability Rating Index (DRI) score at 6 months at the 5% level. The randomisation sequence is stratified by trial centre and age, and administered via web-based service with 1:1 treatment allocation. Baseline demographic and pre-injury functional data and radiographs will be collected using the DRI, Olerud and Molander, and EuroQol EQ-5D questionnaire. Clinical assessment, early complications and radiographs will be recorded at 6–8 weeks. Functional outcome, health-related quality of life and resource use will be collected at 3, 6 and 12 months postoperatively. The main analysis will investigate differences in DRI 6 months postsurgery, between the two treatment groups, on an intention-to-treat basis. Tests will be two-sided and considered to provide evidence for a significant difference if p values are <0.05. Ethics and dissemination NRES Committee West-Midlands, 6/11/2012 (ref:12/WM/0340). The results of the trial will be disseminated via peer-reviewed publications and presentations at relevant conferences. Trial registration number ISRCTN99771224. PMID:26384729
Kim, Joon-Woo; Oh, Chang-Wug; Oh, Jong-Keon; Kyung, Hee-Soo; Park, Kyeong-Hyeon; Kim, Hee-June; Jung, Jae-Wook; Jung, Young-Soo
2017-06-01
High-energy proximal tibial fractures often accompany compartment syndrome and are usually treated by fasciotomy with external fixation followed by secondary plating. However, the initial soft tissue injury may affect bony union, the fasciotomy incision or external fixator pin sites may lead to postoperative wound infections, and the staged procedure itself may adversely affect lower limb function. We assess the results of staged minimally invasive plate osteosynthesis (MIPO) for proximal tibial fractures with acute compartment syndrome. Twenty-eight patients with proximal tibial fractures accompanied by acute compartment syndrome who underwent staged MIPO and had a minimum of 12 months follow-up were enrolled. According to the AO/OTA classification, 6 were 41-A, 15 were 41-C, 2 were 42-A and 5 were 42-C fractures; this included 6 cases of open fractures. Immediate fasciotomy was performed once compartment syndrome was diagnosed and stabilization of the fracture followed using external fixation. After the soft tissue condition normalized, internal conversion with MIPO was done on an average of 37 days (range, 9-158) after index trauma. At the time of internal conversion, the external fixator pin site grades were 0 in 3 cases, 1 in 12 cases, 2 in 10 cases and 3 in 3 cases, as described by Dahl. Radiographic assessment of bony union and alignment and a functional assessment using the Knee Society Score and American Orthopedic Foot and Ankle Society (AOFAS) score were carried out. Twenty-six cases achieved primary bony union at an average of 18.5 weeks. Two cases of nonunion healed after autogenous bone grafting. The mean Knee Society Score and the AOFAS score were 95 and 95.3 respectively, at last follow-up. Complications included 1 case of osteomyelitis in a patient with a grade IIIC open fracture and 1 case of malunion caused by delayed MIPO due to poor wound conditions. Duration of external fixation and the external fixator pin site grade were not related to the occurrence of infection. Staged MIPO for proximal tibial fractures with acute compartment syndrome may achieve satisfactory bony union and functional results, while decreasing deep infections and soft tissue complications. Copyright © 2017 Elsevier Ltd. All rights reserved.
Dillard, Michael B; Warm, Joel S; Funke, Gregory J; Funke, Matthew E; Finomore, Victor S; Matthews, Gerald; Shaw, Tyler H; Parasuraman, Raja
2014-12-01
In this study, we evaluated the validity of the Sustained Attention to Response Task (SART) as a means for promoting mindlessness in vigilance performance. Vigilance tasks typically require observers to respond to critical signals and to withhold responding to neutral events. The SART features the opposite response requirements, which supposedly leads it to promote a mindless, non-thoughtful approach to the vigilance task To test that notion, we compared the SART to the traditional vigilance format (TVF) in terms of diagnostic accuracy assessed through decision theory measures of positive and negative predictive power (PPP and NPP), perceived mental workload indexed by the Multiple Resource Questionnaire, and oculomotor activity reflected in the Nearest Neighbor Index and fixation dwell times. Observers in TVF and SART conditions monitored a video display for collision flight paths in a simulated air traffic control task. Diagnostic accuracy in terms of NPP was high in both format conditions. While PPP was poorer in the SART than in the TVF, that result could be accounted for by a loss of motor control rather than a lack of mindfulness. Identical high levels of workload were generated by the TVF and SART tasks, and observers in both conditions showed similar dynamic scanning of the visual scene. The data indicate that the SART is not an engine of mindlessness. The results challenge the widespread use of the SART to support a model in which mindlessness is considered to be the principal root of detection failures in vigilance.
Durham, Myra E; Sod, Gary A; Riggs, Laura M; Mitchell, Colin F
2015-02-01
To compare the monotonic biomechanical properties of a broad 4.5 mm limited contact-dynamic compression plate (LC-DCP) fixation secured with hydroxyapatite (HA) coated cortical bone screws (HA-LC-DCP) versus uncoated cortical bone screws (AO-LC-DCP) to repair osteotomized equine 3rd metacarpal (MC3) bones. Experimental. Adult equine cadaveric MC3 bones (n = 12 pair). Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for: (1) 4 point bending single cycle to failure testing; (2) 4 point bending cyclic fatigue testing; and (3) torsional single cycle to failure testing. For the HA-LC-DCP-MC3 construct, an 8-hole broad LC-DCP (Synthes Ltd, Paoli, PA) was secured on the dorsal surface of each randomly selected MC3 bone with a combination of four 5.5 mm and four 4.5 mm HA-coated cortical screws. For the AO-LC-DCP-MC3 construct, an 8-hole 4.5 mm broad LC-DCP was secured on the dorsal surface of the contralateral MC3 bone with a combination of four 5.5 mm and four 4.5 mm uncoated cortical screws. All MC3 bones had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P < .05. Mean yield load, yield bending moment, composite rigidity, failure load, and failure bending moment, under 4 point bending, single cycle to failure, of the HA-LC-DCP fixation were significantly greater than those of the AO-LC-DCP fixation. Mean ± SD values for the HA-LC-DCP and the AO-LC-DCP fixation techniques, respectively, in single cycle to failure under 4 point bending were: yield load, 26.7 ± 2.15 and 16.3 ± 1.38 kN; yield bending moment, 527.4 ± 42.4 and 322.9 ± 27.2 N-m; composite rigidity, 5306 ± 399 and 3003 ± 300 N-m/rad; failure load, 40.6 ± 3.94 and 26.5 ± 2.52 kN; and failure bending moment, 801.9 ± 77.9 and 522.9 ± 52.2 N-m. Mean cycles to failure in 4 point bending of the HA-LC-DCP fixation (116,274 ± 13,211) was significantly greater than that of the AO-LC-DCP fixation 47,619 ± 6580. Mean yield load, mean composite rigidity, and mean failure load under torsional testing, single cycle to failure was significantly greater for the broad HA-LC-DCP fixation compared with the AO-LC-DCP fixation. In single cycle to failure under torsion, mean ± SD values for the HA-LC-DCP and the AO-LC-DCP fixation techniques, respectively, were: yield load, 101.3 ± 14.68 and 70.54 ± 10.20 N-m; composite rigidity, 437.9 ± 32.9 and 220.7 ± 17.6 N-m/rad; and failure load: 105.7 ± 15.5 and 75.28 ± 10.1 N-m. HA-LC-DCP was superior to AO-LC-DCP in resisting the static overload forces (palmarodorsal 4 point bending and torsional) and in resisting cyclic fatigue under palmarodorsal 4 point bending. © Copyright 2014 by The American College of Veterinary Surgeons.
Barban, P S; Minaeva, V M; Pantiukhina, A N; Startseva, M G
1976-06-01
A comparative study was made of the serological properties and virus-neutralizing activity of antiencephalitis gamma-globulin and Fab-fragments isolated from it by gel-filtration. Horse immunoglobulins against the autumno-summer tick-borne encephalitis virus could be disintegrated with the aid of papaine to monovalent Fab-fragments which (according to the complement fixation reaction, the test of suppression of the complement fixation, and the HAIT) retained the serological activity whose level was compared with that of the serological activity of gamma-globulin. Fab-fragments possessed a marked virus-neutralizing activity. The mean value of a logarithm of the neutralization index was 2.65 +/- 0.2 for Fab-fragments and 3.74 +/- 0.38 for gamma-globulin (P less than 0.01).
Scholz, Timo; Zech, Astrid; Wegscheider, Karl; Lezius, Susanne; Braumann, Klaus-Michael; Sehner, Susanne; Hollander, Karsten
2017-09-01
Measurement of the medial longitudinal foot arch in children is a controversial topic, as there are many different methods without a definite standard procedure. The purpose of this study was to 1) investigate intraday and interrater reliability regarding dynamic arch index and static arch height, 2) explore the correlation between both arch indices, and 3) examine the variation of the medial longitudinal arch at two different times of the day. Eighty-six children (mean ± SD age, 8.9 ± 1.9 years) participated in the study. Dynamic footprint data were captured with a pedobarographic platform. For static arch measurements, a specially constructed caliper was used to assess heel-to-toe length and dorsum height. A mixed model was established to determine reliability and variation. Reliability was found to be excellent for the static arch height index in sitting (intraday, 0.90; interrater, 0.80) and standing positions (0.88 and 0.85) and for the dynamic arch index (both 1.00). There was poor correlation between static and dynamic assessment of the medial longitudinal arch (standing dynamic arch index, r = -0.138; sitting dynamic arch index, r = -0.070). Static measurements were found to be significantly influenced by the time of day (P < .001), whereas the dynamic arch index was unchanged (P = .845). This study revealed some further important findings. The static arch height index is influenced by gender (P = .004), whereas dynamic arch index is influenced by side (P = .011) and body mass index (P < .001). Dynamic and static foot measurements are reliable for medial longitudinal foot arch assessment in children. The variation of static arch measurements during the day has to be kept in mind. For clinical purposes, static and dynamic arch data should be interpreted separately.
The addition of body armor diminishes dynamic postural stability in military soldiers.
Sell, Timothy C; Pederson, Jonathan J; Abt, John P; Nagai, Takashi; Deluzio, Jennifer; Wirt, Michael D; McCord, Larry J; Lephart, Scott M
2013-01-01
Poor postural stability has been identified as a risk factor for lower extremity musculoskeletal injury. The additional weight of body armor carried by Soldiers alters static postural stability and may predispose Soldiers to lower extremity musculoskeletal injuries. However, static postural stability tasks poorly replicate the dynamic military environment, which places considerable stress on the postural control system during tactical training and combat. Therefore, the purpose of this study was to examine the effects of body armor on dynamic postural stability during single-leg jump landings. Thirty-six 101st Airborne Division (Air Assault) Soldiers performed single-leg jump landings in the anterior direction with and without wearing body armor. The dynamic postural stability index and the individual stability indices (medial-lateral stability index, anterior-posterior stability index, and vertical stability index) were calculated for each condition. Paired sample t-tests were performed to determine differences between conditions. Significant differences existed for the medial-lateral stability index, anterior-posterior stability index, vertical stability index, and dynamic postural stability index (p < 0.05). The addition of body armor resulted in diminished dynamic postural stability, which may result in increased lower extremity injuries. Training programs should address the altered dynamic postural stability while wearing body armor in attempts to promote adaptations that will result in safer performance during dynamic tasks.
Intraoperative CT in the assessment of posterior wall acetabular fracture stability.
Cunningham, Brian; Jackson, Kelly; Ortega, Gil
2014-04-01
Posterior wall acetabular fractures that involve 10% to 40% of the posterior wall may or may not require an open reduction and internal fixation. Dynamic stress examination of the acetabular fracture under fluoroscopy has been used as an intraoperative method to assess joint stability. The aim of this study was to demonstrate the value of intraoperative ISO computed tomography (CT) examination using the Siemens ISO-C imaging system (Siemens Corp, Malvern, Pennsylvania) in the assessment of posterior wall acetabular fracture stability during stress examination under anesthesia. In 5 posterior wall acetabular fractures, standard fluoroscopic images (including anteroposterior pelvis and Judet radiographs) with dynamic stress examinations were compared with the ISO-C CT imaging system to assess posterior wall fracture stability during stress examination. After review of standard intraoperative fluoroscopic images under dynamic stress examination, all 5 cases appeared to demonstrate posterior wall stability; however, when the intraoperative images from the ISO-C CT imaging system demonstrated that 1 case showed fracture instability of the posterior wall segment during stress examination, open reduction and internal fixation was performed. The use of intraoperative ISO CT imaging has shown an initial improvement in the surgeon's ability to assess the intraoperative stability of posterior wall acetabular fractures during stress examination when compared with standard fluoroscopic images. Copyright 2014, SLACK Incorporated.
Patova, Elena; Sivkov, Michail; Patova, Anna
2016-09-01
The nitrogen fixation by biological soil crusts with a dominance of cyanobacteria was studied using the acetylene reduction assay in the territory of the Subpolar Urals (65°11' N, 60°18' E), Russia. The field measurements of nitrogen fixation activity were conducted in situ for two different types of soil crusts dominated by Stigonema (V1 type) and Nostoc with Scytonema (V2 type). The nitrogen fixation process had similar dynamics in both crusts but nitrogen fixation rates were different. The crusts of the V2 type showed a significantly higher acetylene reduction activity, with ethylene production rate of 1.76 ± 0.49 g C2H4 m(-2) h(-1) at 15°C, compared with V1-type soil crusts, with a rate of 0.53 ± 0.21 mg C2H4 m(-2) h(-1) at 15°C. The daily value of acetylene reduction activity in V2-type soil crusts was 32.7 ± 6.2 mg C2H4 m(-2) d(-1) and in V1-type crusts, 12.3 ± 1.8 mg C2H4 m(-2) d(-1) After recalculation for N, the daily values of nitrogen fixation were in the range 3.3-22.3 mg N m(-2) d(-1), which is a few times higher than the values of N input from the precipitation to the soil in the studied regions. The dependence of nitrogen-fixation activity on temperature and light intensity of biological soil crusts was investigated. On the basis of temperature models obtained from the dependence, the nitrogen balance was calculated for the growing season (approximately 120 days). The crusts dominated by Stigonema species were fixing 0.3 g N m(-2) (ethylene production rate, 1.10 g C2H4 m(-2)) and crusts dominated by Nostoc and Scytonema were fixing 1.3 g N m(-2) (4.10 g C2H4 m(-2)). © FEMS 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Costa, Matthew L; Achten, Juul; Hennings, Susie; Boota, Nafisa; Griffin, James; Petrou, Stavros; Maredza, Mandy; Dritsaki, Melina; Wood, Thomas; Masters, James; Pallister, Ian; Lamb, Sarah E; Parsons, Nick R
2018-05-01
The best treatment for fractures of the distal tibia remains controversial. Most of these fractures require surgical fixation, but the outcomes are unpredictable and complications are common. To assess disability, quality of life, complications and resource use in patients treated with intramedullary (IM) nail fixation versus locking plate fixation in the 12 months following a fracture of the distal tibia. This was a multicentre randomised trial. The trial was conducted in 28 UK acute trauma centres from April 2013 to final follow-up in February 2017. In total, 321 adult patients were recruited. Participants were excluded if they had open fractures, fractures involving the ankle joint, contraindication to nailing or inability to complete questionnaires. IM nail fixation ( n = 161), in which a metal rod is inserted into the hollow centre of the tibia, versus locking plate fixation ( n = 160), in which a plate is attached to the surface of the tibia with fixed-angle screws. The primary outcome measure was the Disability Rating Index (DRI) score, which ranges from 0 points (no disability) to 100 points (complete disability), at 6 months with a minimum clinically important difference of 8 points. The DRI score was also collected at 3 and 12 months. The secondary outcomes were the Olerud-Molander Ankle Score (OMAS), quality of life as measured using EuroQol-5 Dimensions (EQ-5D), complications such as infection, and further surgery. Resource use was collected to inform the health economic evaluation. Participants had a mean age of 45 years (standard deviation 16.2 years), were predominantly male (61%, 197/321) and had experienced traumatic injury after a fall (69%, 223/321). There was no statistically significant difference in DRI score at 6 months [IM nail fixation group, mean 29.8 points, 95% confidence interval (CI) 26.1 to 33.7 points; locking plate group, mean 33.8 points, 95% CI 29.7 to 37.9 points; adjusted difference, 4.0 points, 95% CI -1.0 to 9.0 points; p = 0.11]. There was a statistically significant difference in DRI score at 3 months in favour of IM nail fixation (IM nail fixation group, mean 44.2 points, 95% CI 40.8 to 47.6 points; locking plate group, mean 52.6 points, 95% CI 49.3 to 55.9 points; adjusted difference 8.8 points, 95% CI 4.3 to 13.2 points; p < 0.001), but not at 12 months (IM nail fixation group, mean 23.1 points, 95% CI 18.9 to 27.2 points; locking plate group, 24.0 points, 95% CI 19.7 to 28.3 points; adjusted difference 1.9 points, 95% CI -3.2 to 6.9 points; p = 0.47). Secondary outcomes showed the same pattern, including a statistically significant difference in mean OMAS and EQ-5D scores at 3 and 6 months in favour of IM nail fixation. There were no statistically significant differences in complications, including the number of postoperative infections (13% in the locking plate group and 9% in the IM nail fixation group). Further surgery was more common in the locking plate group (12% in locking plate group and 8% in IM nail fixation group at 12 months). The economic evaluation showed that IM nail fixation provided a slightly higher quality of life in the 12 months after injury and at lower cost and, therefore, it was cost-effective compared with locking plate fixation. The probability of cost-effectiveness for IM nail fixation exceeded 90%, regardless of the value of the cost-effectiveness threshold. As wound dressings after surgery are clearly visible, it was not possible to blind the patients to their treatment allocation. This evidence does not apply to intra-articular (pilon) fractures of the distal tibia. Among adults with an acute fracture of the distal tibia who were randomised to IM nail fixation or locking plate fixation, there were similar disability ratings at 6 months. However, recovery across all outcomes was faster in the IM nail fixation group and costs were lower. The potential benefit of IM nail fixation in several other fractures requires investigation. Research is also required into the role of adjuvant treatment and different rehabilitation strategies to accelerate recovery following a fracture of the tibia and other long-bone fractures in the lower limb. The patients in this trial will remain in longer-term follow-up. Current Controlled Trials ISRCTN99771224 and UKCRN 13761. This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment ; Vol. 22, No. 25. See the NIHR Journals Library website for further project information.
Fang, C; Lau, T W; Wong, T M; Lee, H L; Leung, F
2015-03-01
The spiral blade modification of the Dynamic Hip Screw (DHS) was designed for superior biomechanical fixation in the osteoporotic femoral head. Our objective was to compare clinical outcomes and in particular the incidence of loss of fixation. In a series of 197 consecutive patients over the age of 50 years treated with DHS-blades (blades) and 242 patients treated with conventional DHS (screw) for AO/OTA 31.A1 or A2 intertrochanteric fractures were identified from a prospectively compiled database in a level 1 trauma centre. Using propensity score matching, two groups comprising 177 matched patients were compiled and radiological and clinical outcomes compared. In each group there were 66 males and 111 females. Mean age was 83.6 (54 to 100) for the conventional DHS group and 83.8 (52 to 101) for the blade group. Loss of fixation occurred in two blades and 13 DHSs. None of the blades had observable migration while nine DHSs had gross migration within the femoral head before the fracture healed. There were two versus four implant cut-outs respectively and one side plate pull-out in the DHS group. There was no significant difference in mortality and eventual walking ability between the groups. Multiple logistic regression suggested that poor reduction (odds ratio (OR) 11.49, 95% confidence intervals (CI) 1.45 to 90.9, p = 0.021) and fixation by DHS (OR 15.85, 95%CI 2.50 to 100.3, p = 0.003) were independent predictors of loss of fixation. The spiral blade design may decrease the risk of implant migration in the femoral head but does not reduce the incidence of cut-out and reoperation. Reduction of the fracture is of paramount importance since poor reduction was an independent predictor for loss of fixation regardless of the implant being used. Cite this article: Bone Joint J 2015;97-B:398-404. ©2015 The British Editorial Society of Bone & Joint Surgery.
Evolutionary dynamics of fluctuating populations with strong mutualism
NASA Astrophysics Data System (ADS)
Chotibut, Thiparat; Nelson, David
2013-03-01
Evolutionary game theory with finite interacting populations is receiving increased attention, including subtle phenomena associated with number fluctuations, i.e., ``genetic drift.'' Models of cooperation and competition often utilize a simplified Moran model, with a strictly fixed total population size. We explore a more general evolutionary model with independent fluctuations in the numbers of two distinct species, in a regime characterized by ``strong mutualism.'' The model has two absorbing states, each corresponding to fixation of one of the two species, and allows exploration of the interplay between growth, competition, and mutualism. When mutualism is favored, number fluctuations eventually drive the system away from a stable fixed point, characterized by cooperation, to one of the absorbing states. Well-mixed populations will thus be taken over by a single species in a finite time, despite the bias towards cooperation. We calculate both the fixation probability and the mean fixation time as a function of the initial conditions and carrying capacities in the strong mutualism regime, using the method of matched asymptotic expansions. Our results are compared to computer simulations.
Kwiatkowska, Maria; Stępiński, Dariusz; Polit, Justyna T; Popłońska, Katarzyna; Wojtczak, Agnieszka
2011-01-01
Lipotubuloids, structures containing lipid bodies and microtubules, are described in ovary epidermal cells of Ornithogalum umbellatum. Microtubules of lipotubuloids can be fixed in electron microscope fixative containing only buffered OsO(4) or in glutaraldehyde with OsO(4) post-fixation, or in a mixture of OsO(4) and glutaraldehyde. None of these substances fixes cortical microtubules of ovary epidermis of this plant which is characterized by dynamic longitudinal growth. However, cortical microtubules can be fixed with cold methanol according immunocytological methods with the use of β-tubulin antibodies and fluorescein. The existence of cortical microtubules has also been evidenced by EM observations solely after the use of taxol, microtubule stabilizer, and fixation in a glutaraldehyde/OsO(4) mixture. These microtubules mostly lie transversely, sometimes obliquely, and rarely parallel to the cell axis. Staining, using Ruthenium Red and silver hexamine, has revealed that lipotubuloid microtubules surface is covered with polysaccharides. The presumption has been made that the presence of a polysaccharide layer enhances the stability of lipotubuloid microtubules.
De Luis, Ana; Markmann, Katharina; Cognat, Valérie; Holt, Dennis B.; Charpentier, Myriam; Parniske, Martin; Stougaard, Jens; Voinnet, Olivier
2012-01-01
Legumes overcome nitrogen shortage by developing root nodules in which symbiotic bacteria fix atmospheric nitrogen in exchange for host-derived carbohydrates and mineral nutrients. Nodule development involves the distinct processes of nodule organogenesis, bacterial infection, and the onset of nitrogen fixation. These entail profound, dynamic gene expression changes, notably contributed to by microRNAs (miRNAs). Here, we used deep-sequencing, candidate-based expression studies and a selection of Lotus japonicus mutants uncoupling different symbiosis stages to identify miRNAs involved in symbiotic nitrogen fixation. Induction of a noncanonical miR171 isoform, which targets the key nodulation transcription factor Nodulation Signaling Pathway2, correlates with bacterial infection in nodules. A second candidate, miR397, is systemically induced in the presence of active, nitrogen-fixing nodules but not in that of noninfected or inactive nodule organs. It is involved in nitrogen fixation-related copper homeostasis and targets a member of the laccase copper protein family. These findings thus identify two miRNAs specifically responding to symbiotic infection and nodule function in legumes. PMID:23071252
Conventional bone plate fixation of distal radius and ulna fractures in toy breed dogs.
Ramírez, J M; Macías, C
2016-03-01
To describe the outcome of bone plate fixation of distal radius and ulna fractures in toy breed dogs treated with conventional bone plates. Records of 15 toy breed dogs with distal radius and ulna fractures were retrospectively reviewed for signalment, method of fixation, complications and clinical and radiographic assessments. A telephone-based owner questionnaire was conducted to determine long-term function and client satisfaction. Age ranged from 4 months to 6 years. Body weight ranged from 1 to 4 kg. Dynamic compression plates were used in 13 dogs and veterinary cuttable plates were used in 2 dogs as the means of fixation. Full radiographic and clinical follow-up data were available for 10 dogs and follow-up was performed between 6 and 8 weeks postoperatively. At that time, all fractures had healed and return to function was considered excellent in all 10 dogs. Five dogs did not return for hospital evaluation because they were judged by their owners to be free of lameness. In two cases, owners could not be contacted by telephone, but the referring veterinarians reported the dogs to be asymptomatic. No major complications occurred. Conventional bone plates are suitable choices for stabilisation of distal radius and ulna fractures in toy breed dogs and are not necessarily correlated with high rates of complication. © 2016 Australian Veterinary Association.
Fixation of strategies driven by switching probabilities in evolutionary games
NASA Astrophysics Data System (ADS)
Xu, Zimin; Zhang, Jianlei; Zhang, Chunyan; Chen, Zengqiang
2016-12-01
We study the evolutionary dynamics of strategies in finite populations which are homogeneous and well mixed by means of the pairwise comparison process, the core of which is the proposed switching probability. Previous studies about this subject are usually based on the known payoff comparison of the related players, which is an ideal assumption. In real social systems, acquiring the accurate payoffs of partners at each round of interaction may be not easy. So we bypass the need of explicit knowledge of payoffs, and encode the payoffs into the willingness of any individual shift from her current strategy to the competing one, and the switching probabilities are wholly independent of payoffs. Along this way, the strategy updating can be performed when game models are fixed and payoffs are unclear, expected to extend ideal assumptions to be more realistic one. We explore the impact of the switching probability on the fixation probability and derive a simple formula which determines the fixation probability. Moreover we find that cooperation dominates defection if the probability of cooperation replacing defection is always larger than the probability of defection replacing cooperation in finite populations. Last, we investigate the influences of model parameters on the fixation of strategies in the framework of three concrete game models: prisoner's dilemma, snowdrift game and stag-hunt game, which effectively portray the characteristics of cooperative dilemmas in real social systems.
Fernández, Gerardo; Sapognikoff, Marcelo; Guinjoan, Salvador; Orozco, David; Agamennoni, Osvaldo
2016-07-01
The current study analyze the effect of word properties (i.e., word length, word frequency and word predictability) on the eye movement behavior of patients with schizophrenia (SZ) compared to age-matched controls. 18 SZ patients and 40 age matched controls participated in the study. Eye movements were recorded during reading regular sentences by using the eyetracking technique. Eye movement analyses were performed using linear mixed models. Analysis of eye movements revealed that patients with SZ decreased the amount of single fixations, increased their total number of second pass fixations compared with healthy individuals (Controls). In addition, SZ patients showed an increase in gaze duration, compared to Controls. Interestingly, the effects of current word frequency and current word length processing were similar in Controls and SZ patients. The high rate of second pass fixations and its low rate in single fixation might reveal impairments in working memory when integrating neighbor words. In contrast, word frequency and length processing might require less complex mechanisms, which were functioning in SZ patients. To the best of our knowledge, this is the first study measuring how patients with SZ process dynamically well-defined words embedded in regular sentences. The findings suggest that evaluation of the resulting changes in eye movement behavior may supplement current symptom-based diagnosis. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Pfreundt, U.; Van Wambeke, F.; Bonnet, S.; Hess, W. R.
2015-12-01
N2 fixation fuels ~ 50 % of new primary production in the oligotrophic South Pacific Ocean. The VAHINE experiment has been designed to track the fate of diazotroph derived nitrogen (DDN) and carbon within a coastal lagoon ecosystem in a comprehensive way. For this, large-volume (~ 50 m3) mesocosms were deployed in the New Caledonia lagoon and were intentionally fertilized with dissolved inorganic phosphorus (DIP) to stimulate N2 fixation. This study examined the temporal dynamics of the prokaryotic community together with the evolution of biogeochemical parameters for 23 consecutive days in one of these mesocosms (M1) and in the Nouméa lagoon using MiSeq 16S rRNA gene sequencing. We observed clear successions within M1, some of which were not mirrored in the lagoon. The dominating classes in M1 were alpha- and gammaproteobacteria, cyanobacteria (mainly Synechococcus), eukaryotic microalgae, on days 10 and 14 Marine Group II euryarchaea, on days 12-23 also Flavobacteriia. Enclosure led to significant changes in the M1 microbial community, probably initiated by the early decay of Synechococcus and diatoms. However, we did not detect a pronounced bottle effect with a copiotroph-dominated community. The fertilization with ~ 0.8 μM DIP on day 4 did not have directly observable effects on the overall community within M1, as the data samples obtained from before and four days after fertilization clustered together, but likely influenced the development of individual populations later on, like Defluviicoccus-related bacteria and UCYN-C type diazotrophic cyanobacteria. Growth of UCYN-C led to among the highest N2 fixation rates ever measured in this region and enhanced growth of nearly all abundant heterotrophic groups in M1. We further show that different Rhodobacteraceae were the most efficient heterotrophs in the investigated system and we observed niche partitioning within the SAR86 clade. Whereas the location in- or outside the mesocosm had a significant effect on community composition, the temporal effect was significantly stronger and similar in both locations, suggesting that overarching abiotic factors were more influential than the enclosure. While temporal community changes were evident, prokaryotic diversity (Shannon Index) only declined slightly from ~ 6.5 to 5.7 or 6.05 in the lagoon and M1, respectively, throughout the experiment, highlighting the importance of multiple and varying sources of organic matter maintaining competition.
Factors Associated With Revision Surgery After Internal Fixation of Hip Fractures.
Sprague, Sheila; Schemitsch, Emil H; Swiontkowski, Marc; Della Rocca, Gregory J; Jeray, Kyle J; Liew, Susan; Slobogean, Gerard P; Bzovsky, Sofia; Heels-Ansdell, Diane; Zhou, Qi; Bhandari, Mohit
2018-05-01
Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (for every 5-point increase) (HR 1.19, 95% CI 1.02-1.39; P = 0.027), displaced fracture (HR 2.16, 95% CI 1.44-3.23; P < 0.001), unacceptable quality of implant placement (HR 2.70, 95% CI 1.59-4.55; P < 0.001), and smokers treated with cancellous screws versus smokers treated with a sliding hip screw (HR 2.94, 95% CI 1.35-6.25; P = 0.006). Additionally, for every 10-year decrease in age, participants experienced an average increased risk of 39% for hardware removal. Results of this study may inform future research by identifying high-risk patients who may be better treated with arthroplasty and may benefit from adjuncts to care (HR 1.39, 95% CI 1.05-1.85; P = 0.020). Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.
An alternative graft fixation technique for scaphoid nonunions treated with vascular bone grafting.
Korompilias, Anastasios V; Lykissas, Marios G; Kostas-Agnantis, Ioannis P; Gkiatas, Ioannis; Beris, Alexandros E
2014-07-01
To present our experience with vascularized bone grafting based on the 1,2-intercompartmental supraretinacular artery for the management of established scaphoid nonunion and to investigate the efficacy of graft immobilization with a combination of Kirschner wires and transarticular external fixation. A retrospective chart and radiographic review was conducted for patients with the diagnosis of scaphoid nonunion of the proximal pole or the waist treated with the 1,2-intercompartmental supraretinacular artery-based vascularized graft and fixed with a combination of Kirschner wires and transarticular external fixation between 2007 and 2011. We observed 23 consecutive patients for a mean of 34 ± 4 months. All patients were males with mean age of 25 ± 5 years. All patients had scaphoid nonunion and associated humpback deformity. The mean duration of nonunion was 7 ± 1 months. All scaphoid nonunions united after the index procedure at a mean of 10 ± 1 weeks. Two patients had avascular necrosis of the proximal pole based on the preoperative magnetic resonance imaging findings. After surgery, deformity correction was achieved in all patients, as recorded by the decrease in the lateral intrascaphoid angle and the increase in the dorsal scaphoid angle. At the last follow-up, no patients reported wrist pain. The mean Disabilities of the Arm, Shoulder, and Hand score improved significantly from 32 ± 12 before the operation to 5 ± 3 at the last postoperative visit. All patients showed statistically significant improvement in the range of motion and the grip strength of the involved wrist. The results of this study support the combined use of Kirschner wires and transarticular external fixation for fixation of a 1,2-intercompartmental supraretinacular artery-based vascular bone graft in the treatment of scaphoid nonunions. Therapeutic IV. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Yu, Jaecheon; Ha, Yoon; Shin, Jun Jae; Oh, Jae Keun; Lee, Chang Kyu; Kim, Keung Nyun; Yoon, Do Heum
2017-10-26
To evaluate the efficacy of plate fixation on cervical alignment after anterior cervical discectomy and fusion (ACDF) using a stand-alone cage (ACDF-CA), compared to ACDF performed using a cage and plate fixation (ACDF-CP) and ACDF using autologous iliac bone graft and plate fixation (ACDF-AP), for the treatment of one- or two-level cervical degenerative disease. A second objective was to assess the clinical and radiological outcomes between the groups. A total of 247 patients underwent ACDF and were divided into three groups: those who underwent ACDF-CA (n = 76), ACDF-CP (n = 82) or ACDF-AP (n = 89). Fusion rate and time-to-fusion, global cervical and segmental angle, fused segment height, subsidence rate, and clinical outcomes, were measured using the visual analogue scale (VAS), Oswestry Neck Disability Index (NDI), and Robinson's criteria, assessed preoperatively, immediately postoperatively, and at least 24 months, postoperatively. ACDF-AP was associated with the shortest mean time-to-fusion, followed by ACDF-CP and ACDF-CA. Compared to the preoperative status, the fused segment height and segmental angle increased in all groups immediately postoperatively, being well-maintained in patients who underwent ACDF-AP, while decreasing in those who underwent ACDF-CP and ACDF-CA procedures. Global cervical lordosis increased with ACDF-AP, but decreased immediately postoperatively with ACDF-CP and ACDF-CA, and at the final follow-up. Univariate analysis confirmed that a change in fused segment height was positively associated with a change in both segmental and global cervical angles. Clinical outcomes, namely VAS and NDI scores, as well as Robinson's criteria, were comparable among the three techniques. Supplementation with plate fixation, especially using autologous iliac bone graft, is beneficial for maintaining the fused segment height and cervical spine curvature, as well as reducing time-to-fusion and subsidence rate.
Nevinny-Stickel, Meinhard; Sweeney, Reinhart A; Bale, Reto J; Posch, Andrea; Auberger, Thomas; Lukas, Peter
2004-02-01
Precise reproducible patient positioning is a prerequisite for conformal fractionated radiotherapy. A fixation system based on double-vacuum technology is presented which can be used for conventional as well as hypofractionated stereotactic extracranial radiotherapy. To form the actual vacuum mattress, the patient is pressed into the mattress with a vacuum foil which can also be used for daily repositioning and fixation. A stereotactic frame can be positioned over the region of interest on an indexed base plate. Repositioning accuracy was determined by comparing daily, pretreatment, orthogonal portal images to the respective digitally reconstructed radiographs (DRRs) in ten patients with abdominal and pelvic lesions receiving extracranial fractionated (stereotactic) radiotherapy. The three-dimensional (3-D) vectors and 95% confidence intervals (CI) were calculated from the respective deviations in the three axes. Time required for initial mold production and daily repositioning was also determined. The mean 3-D repositioning error (187 fractions) was 2.5 +/- 1.1 mm. The largest single deviation (10 mm) was observed in a patient treated in prone position. Mold production took an average of 15 min (10-30 min). Repositioning times are not necessarily longer than using no positioning aid at all. The presented fixation system allows reliable, flexible and efficient patient positioning for extracranial stereotactic radiotherapy.
Outcome of locking compression plates in humeral shaft nonunions
Kumar, Malhar N; Ravindranath, V Pratap; Ravishankar, MR
2013-01-01
Background: Nonunion of diaphyseal fractures of the humerus are frequently seen in clinical practice (incidence of up to 15% in certain studies) and osteosynthesis using dynamic compression plates, intra medullary nails and Ilizarov fixators have been reported previously. Locking compression plates (LCP) are useful in the presence of disuse osteoporosis, segmental bone loss and cortical defects that preclude strong fixation. We report a prospective followup study of the outcome of the use of LCP for humeral nonunion following failed internal fixation in which implants other than LCP had been used. Materials and Methods: Twenty four patients with nonunion of humeral shaft fractures following failed internal fixation were included in the study. The mean followup period was 3.4 years (range: 2.4 to 5.7 years) and the minimum followup period was 2 years. Mean age of the patients was 41.04 years (range: 24 to 57 years). All 24 patients underwent osteosynthesis using LCP and autologous bone grafting (cortico-cancellous iliac crest graft combined with or without fibular strut graft). Main outcome measurements included radiographic assessment of fracture union and pre and postoperative functional evaluation using the modified Constant and Murley scoring system. Results: 23 out of 24 fractures united following osteosynthesis. Average time to union was 16 weeks (range: 10 to 28 weeks). Complications included delayed union (n = 2), transient radial nerve palsy (n = 2) and persistent nonunion (n = 1). Functional evaluation using the Constant and Murley score showed excellent results in 11, good in 10, fair in two and poor outcome in one patient. Conclusions: Locking compression plating and cancellous bone grafting is a reliable option for achieving union in humeral diaphyseal nonunion with failed previous internal fixation and results in good functional outcome in patients with higher physiological demands. PMID:23682176
Zhang, Shi-min; Zhang, Zhao-jie; Liu, Yu-zhang; Zhang, Lu-tang; Li, Xing
2011-11-01
To discuss the efficacy of lateral anterior decompression, internal fixation with Ventrofix and bone graft with titanic mesh in the treatment of severe thoracolumbar burst fracture. From January 2008 to January 2010, 21 patients with severe thoracolumbar burst fracture were treated with lateral anterior decompression, internal fixation with Ventrofix, bone graft with titanic mesh. There were 15 males and 6 females, ranging in age from 21 to 46 years with an average of 32.2 years. Segment of fracture: 3 cases were in T11, 6 cases in T12, 7 cases in L1, 5 cases in L2. The mean kyphosis angle was 20.1 degrees and loading of fracture was 7.8 scores. Twenty-one cases accompany with incomplete paralysis. Nerves functions were observed according to Frankel grade; correction and maintain of kyphosis angle were observed by X-rays and CT. All the patients were followed up from 12 to 34 months with an average of 18.5 years. Postoperative complication including injury of pleura in 1 case, dynamic ileus in 2 cases, ilioinguinal nerve injury in 1 case, faulty union of wound in 1 case. All the above complications got recovery after symptomatic treatment. The mean kyphosis angle in fusional segment were 4.2 degrees and the rate of correction was 79%. Nerves functions of all patients got improvement and no internal fixation fail, kyphosis angle obviously lost, titanium mesh shifting, loosening and breakage of screw were found at final follow-up. Lateral anterior decompression, bone graft with titanic mesh, internal fixation with Ventrofix is an idea technique for severe thoracolumber burst fracture, but the method can not be used for patient with severity osteoporosis.
Hernigou, Philippe; Pariat, Jacques
2017-07-01
The first techniques of operative fracture with plates were developed in the 19th century. In fact, at the beginning these methods consisted of an open reduction of the fracture usually followed by a very unstable fixation. As a consequence, the fracture had to be opened with a real risk of (sometimes lethal) infection, and due to unstable fixation, protection with a cast was often necessary. During the period between World Wars I and II, plates for fracture fixation developed with great variety. It became increasingly recognised that, because a fracture of a long bone normally heals with minimal resorption at the bone ends, this may result in slight shortening and collapse, so a very rigid plate might prevent such collapse. However, as a consequence, delayed healing was observed unless the patient was lucky enough to have the plate break. One way of dealing with this was to use a slotted plate in which the screws could move axially, but the really important advance was recognition of the role of compression. After the first description of compression by Danis with a "coapteur", Bagby and Müller with the AO improved the technique of compression. The classic dynamic compression plates from the 1970s were the key to a very rigid fixation, leading to primary bone healing. Nevertheless, the use of strong plates resulted in delayed union and the osteoporosis, cancellous bone, comminution, and/or pathological bone resulted in some failures due to insufficient stability. Finally, new devices represented by locking plates increased the stability, contributing to the principles of a more biological osteosynthesis while giving enough stability to allow immediate full weight bearing in some patients.
Vidyadhara, S; Rao, S K
2007-03-01
Juxta-articular aggressive and recurrent giant cell tumors around the knee pose difficulties in management. This article reviews current problems and options in the management of these giant cell tumors. A systematic search was performed on juxta-articular aggressive and recurrent giant cell tumor. Additional information was retrieved from hand searching the literature and from relevant congress proceedings. We addressed the following issues: general consensus on early diagnosis and techniques in its management. In particular, we describe our results with resection arthrodesis performed combining the benefits of both interlocking intramedullary nail and Ilizarov fixator in the management of these tumors around the knee. Mean operative age of the 22 patients undergoing resection arthrodesis was 35.63 years. Seven lesions were in the tibia and fifteen in the femur. Mean length of the bone defect was 12.34 cm. The mean external fixator index was 7.44 days/cm and the distraction index was 7.88 days/cm. Mean period of follow-up for the patients was 64.5 months. The function of the affected limb was rated excellent in 10 and good and fair in six patients each as per Enneking criteria. No local recurrence of tumor was seen. Seven complications occurred in five patients. Two-ring construct, bifocal bone transport, and early definite plate osteosynthesis with additional bone grafting of the docking site at the end of distraction even before consolidation of the regenerate helps to reduce the problems of pin tract infections drastically. Thin-diameter long intramedullary nail in addition to preserving the endosteal blood supply also prevents mal-alignment of the regenerate. Thus resection arthrodesis using interlocking intramedullary nail and bone transport using Ilizarov fixator is cost effective and effective in achieving the desired goals of reconstruction with least complications in selected patients with specific indications.
Caruso, Gaetano; Andreotti, Mattia; Pari, Carlotta; Soldati, Francesco; Gildone, Alessandro; Lorusso, Vincenzo; Massari, Leo
2017-01-01
Intramedullary and extramedullary strategies of pertrochanteric fracture fixation are still controversial, but new percutaneous devices may give advantages regarding operative time, blood loss and rate of cardiovascular complications. We retrospectively analyze our cases regarding Anteversa ® plate (Intrauma, Turin, Italy) fixation of pertrochanteric femoral fractures, focusing on the correlation between two radiographical parameters (tip-apex distance "TAD" and calcar referenced tip-apex distance "CalTAD") and the occurrence of cut-out. The purpose of this study was to determine if these predicting factors of cut-out are reliable in the treatment of proximal femoral fractures with the Anteversa plate. A series of 77 patients with 53 31-A1 fracture types and 24-A2 fractures completed a 12-month-follow-up. Clinical outcomes were evaluated according to Parker-Palmer Mobility Score at the final follow-up. TAD and CalTAD were considered to determine their correlation with cut-out events. The mean Parker-Palmer Score was 6.94 in A1 group and 7.41 in A2 group ( p = 0.47). Mean value of TAD index was 29.58, 29.81 in the A1 group and 29.08 in the A2 group, and mean value of CalTAD index was 30.87, 31.03 in the A1 group and 30.50 in the A2 group. We observed 3 cases of implant cut-out. We shared our sample in two groups, one group with TAD and CalTAD indices lower than 25 mm and another group higher than 25 mm to evaluate how the Palmer Parker score changed and no statistical differences were found between the two groups. Taking into consideration that good clinical results were obtained for TAD and CalTAD values superior to 25 mm, the prognostic value of 25 mm of TAD and CalTAD indices might not be appropriate to this new percutaneous plate.
Panchal, Ripul R; Kim, Kee D; Eastlack, Robert; Lopez, John; Clavenna, Andrew; Brooks, Daina M; Joshua, Gita
2017-03-01
To compare radiologic and clinical outcomes, including rates of dysphagia and dysphonia, using a no-profile stand-alone intervertebral spacer with integrated screw fixation versus an anterior cervical plate and spacer construct for single-level anterior cervical discectomy and fusion (ACDF) procedures. This multicenter, randomized, prospective study included 54 patients with degenerative disc disease requiring ACDF at a single level at C3-C7. Twenty-six patients underwent single-level ACDF with stand-alone spacers, and 28 with plate fixation and spacers. Analyses were based on comparison of perioperative outcomes, radiologic and clinical metrics, and incidence of dysphagia and/or dysphonia. Mean patient age was 48.8 ± 10.1years (53.7% female). No significant differences were observed between groups in operative time (101.8 ± 34.4 minutes, 114.4 ± 31.5 minutes), estimated blood loss (44.8 ± 76.5 mL, 82.5 ± 195.1 mL), or length of hospital stay (1.2 ± 0.6 days, 1.3 ± 0.6 days). Mean visual analog scale pain scores and Neck Disability Index scores improved significantly from preoperative to last follow-up (10.8 ± 2.6 months) in both groups (P < 0.05). Mean Voice Handicap Index and Eating Assessment Tool scores improved significantly from discharge to last follow-up in both groups (P < 0.05). From discharge to 6 months, the stand-alone spacers group consistently demonstrated greater improvement in Voice Handicap Index. Preoperative intervertebral disc and neuroforaminal heights increased significantly across treatment groups (P < 0.01), and no cases required surgical revision at index or adjacent levels. Anterior cervical discectomy and fusion with stand-alone spacers resulted in similar clinical and radiologic outcomes as compared with plate and spacers and may help minimize postoperative dysphonia. Copyright © 2016 Elsevier Inc. All rights reserved.
Lenza, Mário; Faloppa, Flávio
2015-05-07
This review covers two conditions: acute clavicle fractures and non-union resulting from failed fracture healing. Clavicle (collarbone) fractures account for around 4% of all fractures. While treatment for these fractures is usually non-surgical, some types of clavicular fractures, as well as non-union of the middle third of the clavicle, are often treated surgically. This is an update of a Cochrane review first published in 2009. To evaluate the effects (benefits and harms) of different methods of surgical treatment for acute fracture or non-union of the middle third of the clavicle. We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register (27 June 2014), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2014, Issue 5), MEDLINE (1966 to June week 3 2014), EMBASE (1988 to 2014 week 25), LILACS (1982 to 27 June 2014), trial registries and reference lists of articles. We applied no language or publication restrictions. We considered randomised and quasi-randomised controlled trials evaluating any surgical intervention for treating people with fractures or non-union of the middle third of the clavicle. The primary outcomes were shoulder function or disability, pain and treatment failure (measured by the number of participants who had undergone or were being considered for a non-routine secondary surgical intervention for symptomatic non-union, malunion or other complications). Two review authors selected eligible trials, independently assessed risk of bias and cross-checked data. Where appropriate, we pooled results of comparable trials. We included seven trials in this review with 398 participants. Four trials were new in this update.The four new trials (160 participants) compared intramedullary fixation with open reduction and internal fixation with plate for treating acute middle third clavicle fractures in adults. Low quality evidence from the four trials indicated that intramedullary fixation did not result in a clinically important improvement in upper arm function (despite a statistically significant difference in its favour: standardised mean difference 0.45, 95% confidence interval (CI) 0.08 to 0.81; 120 participants, three trials) at long term follow-up of six months or more. Very low quality evidence indicated little difference between intramedullary fixation and plate fixation in pain (one trial), treatment failure resulting in non-routine surgery (2/68 with intramedullary fixation vs. 3/65 with plate fixation; risk ratio 0.69, 95% CI 0.16 to 2.97, four trials) or time to clinical fracture consolidation (three trials). There was very low quality evidence of a lower incidence of participants with adverse events (mainly infection, poor cosmetic result and symptomatic hardware) in the intramedullary fixation group (18/68 with intramedullary fixation vs. 27/65 with plate fixation; RR 0.64, 95% CI 0.39 to 1.03) but the CI of the pooled results also included the small possibility of a lower incidence in the plate fixation group. None of the four trials reported on quality of life or return to previous activities. Evidence is pending from two ongoing trials, with planned recruitment of 245 participants, testing this comparison.There was low or very low quality evidence from three small trials, each testing a different comparison. The three trials had design features that carried a high risk of bias, potentially limiting the reliability of their findings. Low-contact dynamic compression plates appeared to be associated with significantly better upper-limb function throughout the year following surgery, earlier fracture union and return to work, and a reduced incidence of implant-associated symptoms when compared with a standard dynamic compression plate in 36 adults with symptomatic non-union of the middle third of the clavicle. One quasi-randomised trial (69 participants) compared Knowles pin versus a plate for treating middle third clavicle fractures or non-union. Knowles pins appeared to be associated with lower pain levels and use of postoperative analgesics and a reduced incidence of implant-associated symptoms. One study (133 participants) found that a three-dimensional technique for fixation with a reconstruction plate was associated with a significantly lower incidence of symptomatic delayed union than a standard superior position surgical approach. Evidence is pending from two ongoing trials, with planned recruitment of 130 participants, comparing anterior versus superior plates for acute fractures. There is very limited and low quality evidence available from randomised controlled trials regarding the effectiveness of different methods of surgical fixation of fractures and non-union of the middle third of the clavicle. The evidence from four ongoing trials is likely to inform practice for the comparisons of intramedullary versus plate fixation and anterior versus superior plates for acute fractures in a future update. Further randomised trials are warranted, but in order to optimise research effort, these should be preceded by research that aims to identify priority questions.
Natural Pyrrhotite as a Catalyst in Prebiotic Chemical Evolution
López Ibáñez de Aldecoa, Alejandra; Velasco Roldán, Francisco; Menor-Salván, César
2013-01-01
The idea of an autotrophic organism as the first living being on Earth leads to the hypothesis of a protometabolic, complex chemical system. In one of the main hypotheses, the first metabolic systems emerged from the interaction between sulfide minerals and/or soluble iron-sulfide complexes and fluids rich in inorganic precursors, which are reduced and derived from crustal or mantle activity. Within this context, the possible catalytic role of pyrrhotite, one of the most abundant sulfide minerals, in biomimetic redox and carbon fixation reactions was studied. Our results showed that pyrrhotite, under simulated hydrothermal conditions, could catalyze the pyruvate synthesis from lactate and that a dynamic system formed by coupling iron metal and iron-sulfur species in an electrochemical cell could promote carbon fixation from thioacetate esters. PMID:25369819
Storyline Visualizations of Eye Tracking of Movie Viewing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Balint, John T.; Arendt, Dustin L.; Blaha, Leslie M.
Storyline visualizations offer an approach that promises to capture the spatio-temporal characteristics of individual observers and simultaneously illustrate emerging group behaviors. We develop a visual analytics approach to parsing, aligning, and clustering fixation sequences from eye tracking data. Visualization of the results captures the similarities and differences across a group of observers performing a common task. We apply our storyline approach to visualize gaze patterns of people watching dynamic movie clips. Storylines mitigate some of the shortcomings of existent spatio-temporal visualization techniques and, importantly, continue to highlight individual observer behavioral dynamics.
Attentional bias to betel quid cues: An eye tracking study.
Shen, Bin; Chiu, Meng-Chun; Li, Shuo-Heng; Huang, Guo-Joe; Liu, Ling-Jun; Ho, Ming-Chou
2016-09-01
The World Health Organization regards betel quid as a human carcinogen, and DSM-IV and ICD-10 dependence symptoms may develop with heavy use. This study, conducted in central Taiwan, investigated whether betel quid chewers can exhibit overt orienting to selectively respond to the betel quid cues. Twenty-four male chewers' and 23 male nonchewers' eye movements to betel-quid-related pictures and matched pictures were assessed during a visual probe task. The eye movement index showed that betel quid chewers were more likely to initially direct their gaze to the betel quid cues, t(23) = 3.70, p < .01, d = .75, and spent more time, F(1, 23) = 4.58, p < .05, η₂ = .17, and were more fixated, F(1, 23) = 5.18, p < .05, η₂ = .18, on them. The visual probe index (response time) failed to detect the chewers' attentional bias. The current study provided the first eye movement evidence of betel quid chewers' attentional bias. The results demonstrated that the betel quid chewers (but not the nonchewers) were more likely to initially direct their gaze to the betel quid cues, and spent more time and were more fixated on them. These findings suggested that when attention is directly measured through the eye tracking technique, this methodology may be more sensitive to detecting attentional biases in betel quid chewers. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
Rood, Akkie; Hannink, Gerjon; Lenting, Anke; Groenen, Karlijn; Koëter, Sander; Verdonschot, Nico; van Kampen, Albert
2015-10-01
Reconstructing the medial patellofemoral ligament (MPFL) has become a key procedure for stabilizing the patella. Different techniques to reconstruct the MPFL have been described: static techniques in which the graft is fixed rigidly to the bone or dynamic techniques with soft tissue fixation. Static MPFL reconstruction is most commonly used. However, dynamic reconstruction deforms more easily and presumably functions more like the native MPFL. The aim of the study was to evaluate the effect of the different MPFL fixation techniques on patellofemoral pressures compared with the native situation. The hypothesis was that dynamic reconstruction would result in patellofemoral pressures closer to those generated in an intact knee. Controlled laboratory study. Seven fresh-frozen knee specimens were tested in an in vitro knee joint loading apparatus. Tekscan pressure-sensitive films fixed to the retropatellar cartilage measured mean patellofemoral and peak pressures, contact area, and location of the center of force (COF) at fixed flexion angles from 0° to 110°. Four different conditions were tested: intact, dynamic, partial dynamic, and static MPFL reconstruction. Data were analyzed using linear mixed models. Static MPFL reconstruction resulted in higher peak and mean pressures from 60° to 110° of flexion (P < .001). There were no differences in pressure between the 2 different dynamic reconstructions and the intact situation (P > .05). The COF in the static reconstruction group moved more medially on the patella from 50° to 110° of flexion compared with the other conditions. The contact area showed no significant differences between the test conditions. After static MPFL reconstruction, the patellofemoral pressures in flexion angles from 60° to 110° were 3 to 5 times higher than those in the intact situation. The pressures after dynamic MPFL reconstruction were similar as compared with those in the intact situation, and therefore, dynamic MPFL reconstruction could be a safer option than static reconstruction for stabilizing the patella. This study showed that static MPFL reconstruction results in higher patellofemoral pressures and thus enhances the chance of osteoarthritis in the long term, while dynamic reconstruction results in more normal pressures. © 2015 The Author(s).
Successional dynamics drive tropical forest nutrient limitation
NASA Astrophysics Data System (ADS)
Chou, C.; Hedin, L. O. O.
2017-12-01
It is increasingly recognized that nutrients such as N and P may significantly constrain the land carbon sink. However, we currently lack a complete understanding of these nutrient cycles in forest ecosystems and how to incorporate them into Earth System Models. We have developed a framework of dynamic forest nutrient limitation, focusing on the role of secondary forest succession and canopy gap disturbances as bottlenecks of high plant nutrient demand and limitation. We used succession biomass data to parameterize a simple ecosystem model and examined the dynamics of nutrient limitation throughout tropical secondary forest succession. Due to the patterns of biomass recovery in secondary tropical forests, we found high nutrient demand from rapid biomass accumulation in the earliest years of succession. Depending on previous land use scenarios, soil nutrient availability may also be low in this time period. Coupled together, this is evidence that there may be high biomass nutrient limitation early in succession, which is partially met by abundant symbiotic nitrogen fixation from certain tree species. We predict a switch from nitrogen limitation in early succession to one of three conditions: (i) phosphorus only, (ii) phosphorus plus nitrogen, or (iii) phosphorus, nitrogen, plus light co-limitation. We will discuss the mechanisms that govern the exact trajectory of limitation as forests build biomass. In addition, we used our model to explore scenarios of tropical secondary forest impermanence and the impacts of these dynamics on ecosystem nutrient limitation. We found that secondary forest impermanence exacerbates nutrient limitation and the need for nitrogen fixation early in succession. Together, these results indicate that biomass recovery dynamics early in succession as well as their connection to nutrient demand and limitation are fundamental for understanding and modeling nutrient limitation of the tropical forest carbon sink.
Treatment of type II odontoid fracture with a novel technique
Zhu, Ce; Wang, Lei; Liu, Hao; Song, Yueming; Liu, Limin; Li, Tao; Gong, Quan
2017-01-01
Abstract Surgical methods for type II odontoid fracture can be classified into 2 main groups: anterior or posterior approach. A more effective way to achieve bone fusion with the lowest possible surgical risk is needed. Therefore, the aim of our study was to describe and evaluate a novel technique, cable-dragged reduction/cantilever beam internal fixation for the treatment of type II odontoid fracture. This was a retrospective study enrolled 34 patients underwent posterior cable-dragged reduction/cantilever-beam internal fixation surgery. Medical records, rates of reduction, the location of the instrumentation and fracture healing during follow-up were analyzed. Once fracture healing was obtained, instrumentation was removed. Neck pain (scored using a visual analog scale [VAS]), neck stiffness, patient satisfaction, and neck disability index (NDI) were recorded before and after removing the instrumentation during follow-up. The mean duration of follow up was 22.8 ± 5.3 months. There was no iatrogenic damage to nerves or blood vessels. Radiographic evaluation showed complete reduction in the 20 patients with fracture displacement and satisfactory fracture healing in all 34 cases. Titanium cable breakage was observed in 4 patients after fracture healing. After removal of instrumentation, significant improvements were seen in neck-pain VAS score, neck stiffness, patient satisfaction, and NDI (all P < .01). Posterior cable-dragged reduction/cantilever-beam internal fixation was an optimal salvage maneuver to conventional surgical methods such as anterior screw fixation and C1–C2 screw-rod system. The operative difficulty and incidence of nerve and vascular injury were reduced. Its major disadvantage is the exposure and screw-setting at C3, which is left intact in traditional surgery, and it is suitable only for patients with intact C1 posterior arches. PMID:29095313
Baioni, Andrea; Di Silvestre, Mario; Greggi, Tiziana; Vommaro, Francesco; Lolli, Francesco; Scarale, Antonio
2015-11-01
Medium- to long-term retrospective evaluation of clinical and radiographic outcome in the treatment of degenerative lumbar diseases with hybrid posterior fixation. Thirty patients were included with the mean age of 47.8 years (range 35 to 60 years). All patients underwent posterior lumbar instrumentation using hybrid fixation for lumbar stenosis with instability (13 cases), degenerative spondylolisthesis Meyerding grade I (6 cases), degenerative disc disease of one or more adjacent levels in six cases and mild lumbar degenerative scoliosis in five patients. Clinical outcomes were evaluated using Oswestry disability index (ODI), Roland and Morris disability questionnaire (RMDQ), and the visual analog scale (VAS) pain scores. All patients were assessed by preoperative, postoperative and follow-up standing plain radiographs and lateral X-rays with flexion and extension. Adjacent disc degeneration was also evaluated by magnetic resonance imaging (MRI) at follow-up. At a mean follow-up of 6.1 years, we observed on X-rays and/or MRI 3 cases of adjacent segment disease (10.0 %): two of them (6.6 %) presented symptoms and recurred a new surgery. The last patient (3.3 %) developed asymptomatic retrolisthesis of L3 not requiring revision surgery. The mean preoperative ODI score was 67.6, RMDQ score was 15.1, VAS back pain score was 9.5, and VAS leg pain score was 8.6. Postoperatively, these values improved to 28.1, 5.4, 3.1, and 2.9, respectively, and remained substantially unchanged at the final follow-up: (27.7, 5.2, 2.9, and 2.7, respectively). After 5-year follow-up, hybrid posterior lumbar fixation presented satisfying clinical outcomes in the treatment of degenerative disease.
Early Weightbearing Protocol in Operative Fixation of Acute Jones Fractures.
Waverly, Brett J; Sorensen, Matthew D; Sorensen, Tyler K
The treatment of Jones fractures has been controversial in terms of nonoperative versus operative management, given the high incidence of nonunion secondary to the delicate blood supply to the proximal fifth metatarsal. We report a retrospective review of a patient cohort treated with an early weightbearing protocol after operative intramedullary fixation in acute Jones fractures. Thirty-one consecutive patients with an acute Jones fracture underwent operative fixation with a single intramedullary solid screw. The postoperative protocol consisted of immediate weightbearing in a controlled ankle motion boot for 2 weeks with a gradual transition to regular shoes at 2 weeks postoperative. At 2 weeks, the patients were allowed to perform low-impact activities such as walking, swimming, biking, or elliptical training. Patients were allowed to return to all activities, as tolerated, regardless of radiographic healing, at 6 weeks postoperatively. Serial postoperative radiographs were taken at 2-week intervals to determine radiographic union. Our patient population consisted of 24 males (77.42%) and 7 females (22.58%), with a mean average age of 37.5 ± 12.59 years and mean average body mass index of 25.7 ± 2.32 kg/m 2 . Fracture union was observed in all 31 patients (100%) at a mean average of 5.7 ± 1.47 (range 4 to 10) weeks. Two (6.5%) patients required hardware removal, with one (3.2%) experiencing sural neuritis. This review of patients undergoing early weightbearing after operative fixation of an acute Jones fracture demonstrated a satisfactory incidence of union compared with traditional postoperative protocols at a mean follow-up duration of 18.58 ± 5.66 months. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Morissette, C; Goulet, J; Lamoureux, G
1991-01-01
A rapid and sensitive screening sandwich enzyme-linked immunosorbent assay (ELISA) was developed for the detection of staphylococcal enterotoxin B (SEB) in cheese by using a highly avid anti-SEB antibody (Ab) as the capture Ab (CAb) and as the biotinylated Ab conjugate. The glutaraldehyde fixation method for the immobilization of CAb on polystyrene dipsticks was superior to the adsorption fixation and the adsorption-glutaraldehyde fixation methods. The glutaraldehyde fixation method resulted in a higher surface-saturating CAb concentration as evaluated by the peroxidase saturation technique and by the ability of the CAb-coated dipstick to discriminate between positive and negative controls (index of discrimination). Of nine blocking agents used alone or in pairs, lysine-human serum albumin, bovine serum albumin, human serum albumin, and gelatin effectively saturated available sites on the CAb-coated dipsticks without causing interference with the antigen-Ab reactions. The addition of 1% polyethylene glycol to the diluent of the biotinylated anti-SEB Ab conjugate improved the detection of SEB. A concentration of 4% polyethylene glycol allowed a 5-min reaction time for the streptavidin-biotin-horseradish peroxidase conjugate. Cheddar cheese homogenate reduced the sensitivity of the SEB assay; however, the sensitivity was restored when 1.6% (wt/vol) of either a nonionic detergent (Mega-9) or two zwitterionic detergents (Zwittergent 3-10 and 3-12 detergent) was added to the diluent. By using the rapid sandwich ELISA, a minimum of 0.5 to 1.0 ng of SEB per ml was detected within 45 min. The whole procedure for the analysis of the cheddar cheese samples was completed within 1 h.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:2039234
El-Tantawy, Ahmad; Atef, Ashraf
2015-04-01
The treatment of intra-articular distal femur fractures with severe metaphyseal comminution is challenging. It is important to choose a technique that provides secure fixation, minimum tissue handling, and early ambulation. The aim of this work was to evaluate the outcomes of application of Ilizarov concept as an early definitive treatment of comminuted distal femur closed fractures. A total of 17 male patients (mean age 28.53±6.33 years) presented with comminuted distal femur fractures (with 10 type C2 and 7 type C3-2 fractures according to AO/ASIF system) were included in this prospective study. Initial fixation of the articular fragments was done by inter-fragmentary screws, percutaneously through a limited open approach, and stabilization was completed by Ilizarov fixator. The procedure included acute shortening, through the comminution, followed by gradual re-distraction to compensate the created shortening. Radiological and functional results were assessed according to ASAMI evaluation system. The mean amount of intra-operative shortening was 3.68±0.53 cm. The mean external fixation index was 37.24±2.53 days/cm. The mean follow-up period was 18.18±1.91 months. All fractures united primarily in an average 137.65±4.12 days, with no evident angular deformity or limb-length discrepancy. None of the cases required a second major procedure or bone graft. The functional results were excellent in three cases, good in 12, and fair in two patients. The Ilizarov concept of acute compression-distraction is a valuable alternative for the treatment of distal femur fractures with severe metaphyseal comminution.
Holistic component of image perception in mammogram interpretation: gaze-tracking study.
Kundel, Harold L; Nodine, Calvin F; Conant, Emily F; Weinstein, Susan P
2007-02-01
To test the hypothesis that rapid and accurate performance of the proficient observer in mammogram interpretation involves a shift in the mechanism of image perception from a relatively slow search-to-find mode to a relatively fast holistic mode. This HIPAA-compliant study had institutional review board approval, and participant informed consent was obtained; patient informed consent was not required. The eye positions of three full-time mammographers, one attending radiologist, two mammography fellows, and three radiology residents were recorded during the interpretation of 20 normal and 20 subtly abnormal mammograms. The search time required to first locate a cancer, as well as the initial eye scan path, was determined and compared with diagnostic performance as measured with receiver operating characteristic (ROC) analysis. The median time for all observers to fixate a cancer, regardless of the decision outcome, was 1.13 seconds, with a range of 0.68 second to 3.06 seconds. Even though most of the lesions were fixated, recognition of them as cancerous ranged from 85% (17 of 20) to 10% (two of 20), with corresponding areas under the ROC curve of 0.87-0.40. The ROC index of detectability, d(a), was linearly related to the time to first fixate a cancer with a correlation (r(2)) of 0.81. The rapid initial fixation of a true abnormality is evidence for a global perceptual process capable of analyzing the visual input of the entire retinal image and pinpointing the spatial location of an abnormality. It appears to be more highly developed in the most proficient observers, replacing the less efficient initial search-to-find strategies. (c) RSNA, 2007.
Sex speeds adaptation by altering the dynamics of molecular evolution.
McDonald, Michael J; Rice, Daniel P; Desai, Michael M
2016-03-10
Sex and recombination are pervasive throughout nature despite their substantial costs. Understanding the evolutionary forces that maintain these phenomena is a central challenge in biology. One longstanding hypothesis argues that sex is beneficial because recombination speeds adaptation. Theory has proposed several distinct population genetic mechanisms that could underlie this advantage. For example, sex can promote the fixation of beneficial mutations either by alleviating interference competition (the Fisher-Muller effect) or by separating them from deleterious load (the ruby in the rubbish effect). Previous experiments confirm that sex can increase the rate of adaptation, but these studies did not observe the evolutionary dynamics that drive this effect at the genomic level. Here we present the first, to our knowledge, comparison between the sequence-level dynamics of adaptation in experimental sexual and asexual Saccharomyces cerevisiae populations, which allows us to identify the specific mechanisms by which sex speeds adaptation. We find that sex alters the molecular signatures of evolution by changing the spectrum of mutations that fix, and confirm theoretical predictions that it does so by alleviating clonal interference. We also show that substantially deleterious mutations hitchhike to fixation in adapting asexual populations. In contrast, recombination prevents such mutations from fixing. Our results demonstrate that sex both speeds adaptation and alters its molecular signature by allowing natural selection to more efficiently sort beneficial from deleterious mutations.
NASA Astrophysics Data System (ADS)
Affatato, S.; Spinelli, M.; Zavalloni, M.; Carmignato, S.; Lopomo, N.; Marcacci, M.; Viceconti, M.
2008-10-01
Knee osteoarthritis is a complex clinical scenario where many biological and mechanical factors influence the severity of articular degenerative changes. Minimally invasive knee prosthetic surgery, with only a compartment replacement (unicompartmental knee replacement), might be a good compromise between osteotomy and total knee prosthesis. The focus of this study was to develop and validate a protocol to assess the fixation method of the femoral components in mechanical simulation, for pre-clinical validation; the wear behaviour of two different fixation frames was quantified and compared. In particular, two different wear tests were conducted using the same knee simulator, the same load profiles and the same kinematics; two different fixation methods were applied to the femoral sleds (synthetic femur and metal block). Surface characterization on both articulating bearings was performed by a roughness measuring machine and coordinate measuring machine. The wear produced by the tibial inserts using the synthetic femur was considerably higher than the wear registered by the metal-block holder. Roughness measurements on femoral sleds showed a limited number of scratches with high Rt values for the metal-block set-up; the damaged surface broadened in the case of femoral condyles and tibial inserts mounted on composite bone, but lower Rt and linear penetration values were measured. The two holding frames showed different wear activities as a consequence of dissimilar dynamic performance. Further observations should be made in vivo to prove the actual importance of synthetic bone simulations and specific material behaviour.
Using Highlighting to Train Attentional Expertise
Roads, Brett; Mozer, Michael C.; Busey, Thomas A.
2016-01-01
Acquiring expertise in complex visual tasks is time consuming. To facilitate the efficient training of novices on where to look in these tasks, we propose an attentional highlighting paradigm. Highlighting involves dynamically modulating the saliency of a visual image to guide attention along the fixation path of a domain expert who had previously viewed the same image. In Experiment 1, we trained naive subjects via attentional highlighting on a fingerprint-matching task. Before and after training, we asked subjects to freely inspect images containing pairs of prints and determine whether the prints matched. Fixation sequences were automatically scored for the degree of expertise exhibited using a Bayesian discriminative model of novice and expert gaze behavior. Highlighted training causes gaze behavior to become more expert-like not only on the trained images but also on transfer images, indicating generalization of learning. In Experiment 2, to control for the possibility that the increase in expertise is due to mere exposure, we trained subjects via highlighting of fixation sequences from novices, not experts, and observed no transition toward expertise. In Experiment 3, to determine the specificity of the training effect, we trained subjects with expert fixation sequences from images other than the one being viewed, which preserves coarse-scale statistics of expert gaze but provides no information about fine-grain features. Observing at least a partial transition toward expertise, we obtain only weak evidence that the highlighting procedure facilitates the learning of critical local features. We discuss possible improvements to the highlighting procedure. PMID:26744839
Using Highlighting to Train Attentional Expertise.
Roads, Brett; Mozer, Michael C; Busey, Thomas A
2016-01-01
Acquiring expertise in complex visual tasks is time consuming. To facilitate the efficient training of novices on where to look in these tasks, we propose an attentional highlighting paradigm. Highlighting involves dynamically modulating the saliency of a visual image to guide attention along the fixation path of a domain expert who had previously viewed the same image. In Experiment 1, we trained naive subjects via attentional highlighting on a fingerprint-matching task. Before and after training, we asked subjects to freely inspect images containing pairs of prints and determine whether the prints matched. Fixation sequences were automatically scored for the degree of expertise exhibited using a Bayesian discriminative model of novice and expert gaze behavior. Highlighted training causes gaze behavior to become more expert-like not only on the trained images but also on transfer images, indicating generalization of learning. In Experiment 2, to control for the possibility that the increase in expertise is due to mere exposure, we trained subjects via highlighting of fixation sequences from novices, not experts, and observed no transition toward expertise. In Experiment 3, to determine the specificity of the training effect, we trained subjects with expert fixation sequences from images other than the one being viewed, which preserves coarse-scale statistics of expert gaze but provides no information about fine-grain features. Observing at least a partial transition toward expertise, we obtain only weak evidence that the highlighting procedure facilitates the learning of critical local features. We discuss possible improvements to the highlighting procedure.
Freitas, Anderson; Torres, Gustavo Melo; Souza, André Cezar de Andrade de Mello e; Maciel, Rafael Almeida; Souto, Diogo Ranier de Macedo; Ferreira, George Neri de Barros
2014-01-01
Objective To statistically analyze the results obtained from biomechanical tests on fixation of femoral neck fractures of Pauwels III type, in synthetic bone, using the dynamic hip system with an anti-rotation screw, versus a control group. Methods Ten synthetic bones from a Brazilian manufacturer (model C1010) were used and divided into two groups: test and control. In the test group, fixation of an osteotomy was performed with 70° of inclination at the level of the femoral neck, using DHS with an anti-rotation screw. The resistance of this fixation was evaluated, along with its rotational deviation at 5 mm of displacement (phase 1) and at 10 mm of displacement (phase 2), which was considered to be failure of synthesis. In the control group, the models were tested in their entirety until femoral neck fracturing occurred. Results The test values in the test group (samples 1–5) in phase 1 were: 1512 N, 1439 N, 1205 N, 1251 N and 1273 N, respectively (mean = 1336 N; standard deviation [SD] = 132 N). The rotational deviations were: 4.90°, 3.27°, 2.62°, 0.66° and 0.66°, respectively (mean = 2.42°; SD = 1.81°). In phase 2, we obtained: 2064 N, 1895 N, 1682 N, 1713 N and 1354 N, respectively (mean = 1742 N; SD = 265 N). The failure loading values in the control group were: 1544 N, 1110 N, 1359 N, 1194 N and 1437 N, respectively (mean = 1329 N; SD = 177 N). The statistical analysis using the Mann–Whitney test showed that the test group presented maximum loading at a displacement of 10 mm, i.e. significantly greater than the failure loading of the control group (p = 0.047). Conclusion The mechanical resistance of the test group was significantly greater than that of the control group. PMID:26229866
Risse, Sarah; Hohenstein, Sven; Kliegl, Reinhold; Engbert, Ralf
2014-01-01
Eye-movement experiments suggest that the perceptual span during reading is larger than the fixated word, asymmetric around the fixation position, and shrinks in size contingent on the foveal processing load. We used the SWIFT model of eye-movement control during reading to test these hypotheses and their implications under the assumption of graded parallel processing of all words inside the perceptual span. Specifically, we simulated reading in the boundary paradigm and analysed the effects of denying the model to have valid preview of a parafoveal word n + 2 two words to the right of fixation. Optimizing the model parameters for the valid preview condition only, we obtained span parameters with remarkably realistic estimates conforming to the empirical findings on the size of the perceptual span. More importantly, the SWIFT model generated parafoveal processing up to word n + 2 without fitting the model to such preview effects. Our results suggest that asymmetry and dynamic modulation are plausible properties of the perceptual span in a parallel word-processing model such as SWIFT. Moreover, they seem to guide the flexible distribution of processing resources during reading between foveal and parafoveal words. PMID:24771996
Modified arthroscopic suture fixation of a displaced tibial eminence fracture.
Lehman, Ronald A; Murphy, Kevin P; Machen, M Shaun; Kuklo, Timothy R
2003-02-01
This study describes a new arthroscopic method using a whip-stitch technique for treating a displaced type III tibial eminence fracture. A 12-year-old girl who sustained a displaced type III tibial eminence fracture was treated with arthroscopic fixation using the Arthrosew disposable suture device (Surgical Dynamics, Norwalk, CT) to place a whip stitch into the anterior cruciate ligament (ACL). The Arthrex ACL guide (Arthrex, Naples, FL) was used to reduce the avulsed tibial spine fragment. Sutures were then passed through the tibial tunnel and secured over a bony bridge with the knee in 20 degrees of flexion. At 9 months, the patient has a full range of motion with normal Lachman and anterior drawer testing, and she has returned to competitive basketball. Radiographs show complete fracture healing. KT-1000 and isokinetic testing at 9-month follow-up show only minimal side-to-side differences. The Arthrosew device provides a significant advantage in the treatment of type III and IV fractures of the tibial eminence by obtaining arthroscopic fixation within the substance of the ACL, thus obviating arthrotomy and hardware placement. This technique also restores the proper length and tension to the ACL, and provides a simplified, reproducible method of treatment for this injury.
A comprehensive prediction and evaluation method of pilot workload
Feng, Chuanyan; Wanyan, Xiaoru; Yang, Kun; Zhuang, Damin; Wu, Xu
2018-01-01
BACKGROUND: The prediction and evaluation of pilot workload is a key problem in human factor airworthiness of cockpit. OBJECTIVE: A pilot traffic pattern task was designed in a flight simulation environment in order to carry out the pilot workload prediction and improve the evaluation method. METHODS: The prediction of typical flight subtasks and dynamic workloads (cruise, approach, and landing) were built up based on multiple resource theory, and a favorable validity was achieved by the correlation analysis verification between sensitive physiological data and the predicted value. RESULTS: Statistical analysis indicated that eye movement indices (fixation frequency, mean fixation time, saccade frequency, mean saccade time, and mean pupil diameter), Electrocardiogram indices (mean normal-to-normal interval and the ratio between low frequency and sum of low frequency and high frequency), and Electrodermal Activity indices (mean tonic and mean phasic) were all sensitive to typical workloads of subjects. CONCLUSION: A multinominal logistic regression model based on combination of physiological indices (fixation frequency, mean normal-to-normal interval, the ratio between low frequency and sum of low frequency and high frequency, and mean tonic) was constructed, and the discriminate accuracy was comparatively ideal with a rate of 84.85%. PMID:29710742
A comprehensive prediction and evaluation method of pilot workload.
Feng, Chuanyan; Wanyan, Xiaoru; Yang, Kun; Zhuang, Damin; Wu, Xu
2018-01-01
The prediction and evaluation of pilot workload is a key problem in human factor airworthiness of cockpit. A pilot traffic pattern task was designed in a flight simulation environment in order to carry out the pilot workload prediction and improve the evaluation method. The prediction of typical flight subtasks and dynamic workloads (cruise, approach, and landing) were built up based on multiple resource theory, and a favorable validity was achieved by the correlation analysis verification between sensitive physiological data and the predicted value. Statistical analysis indicated that eye movement indices (fixation frequency, mean fixation time, saccade frequency, mean saccade time, and mean pupil diameter), Electrocardiogram indices (mean normal-to-normal interval and the ratio between low frequency and sum of low frequency and high frequency), and Electrodermal Activity indices (mean tonic and mean phasic) were all sensitive to typical workloads of subjects. A multinominal logistic regression model based on combination of physiological indices (fixation frequency, mean normal-to-normal interval, the ratio between low frequency and sum of low frequency and high frequency, and mean tonic) was constructed, and the discriminate accuracy was comparatively ideal with a rate of 84.85%.
Emergent Neutrality in Adaptive Asexual Evolution
Schiffels, Stephan; Szöllősi, Gergely J.; Mustonen, Ville; Lässig, Michael
2011-01-01
In nonrecombining genomes, genetic linkage can be an important evolutionary force. Linkage generates interference interactions, by which simultaneously occurring mutations affect each other’s chance of fixation. Here, we develop a comprehensive model of adaptive evolution in linked genomes, which integrates interference interactions between multiple beneficial and deleterious mutations into a unified framework. By an approximate analytical solution, we predict the fixation rates of these mutations, as well as the probabilities of beneficial and deleterious alleles at fixed genomic sites. We find that interference interactions generate a regime of emergent neutrality: all genomic sites with selection coefficients smaller in magnitude than a characteristic threshold have nearly random fixed alleles, and both beneficial and deleterious mutations at these sites have nearly neutral fixation rates. We show that this dynamic limits not only the speed of adaptation, but also a population’s degree of adaptation in its current environment. We apply the model to different scenarios: stationary adaptation in a time-dependent environment and approach to equilibrium in a fixed environment. In both cases, the analytical predictions are in good agreement with numerical simulations. Our results suggest that interference can severely compromise biological functions in an adapting population, which sets viability limits on adaptive evolution under linkage. PMID:21926305
Working memory load modulates microsaccadic rate.
Dalmaso, Mario; Castelli, Luigi; Scatturin, Pietro; Galfano, Giovanni
2017-03-01
Microsaccades are tiny eye movements that individuals perform unconsciously during fixation. Despite that the nature and the functions of microsaccades are still lively debated, recent evidence has shown an association between these micro eye movements and higher order cognitive processes. Here, in two experiments, we specifically focused on working memory and addressed whether differential memory load could be reflected in a modulation of microsaccade dynamics. In Experiment 1, participants memorized a numerical sequence composed of either two (low-load condition) or five digits (high-load condition), appearing at fixation. The results showed a reduction in the microsaccadic rate in the high-load compared to the low-load condition. In Experiment 2, five red or green digits were always presented at fixation. Participants either memorized the color (low-load condition) or the five digits (high-load condition). Hence, visual stimuli were exactly the same in both conditions. Consistent with Experiment 1, microsaccadic rate was lower in the high-load than in the low-load condition. Overall, these findings reveal that an engagement of working memory can have an impact on microsaccadic rate, consistent with the view that microsaccade generation is pervious to top-down processes.
Surgical repair of femoral fractures in New World camelids: five cases (1996-2003).
Shoemaker, R W; Wilson, D G
2007-04-01
Five New World camelids were admitted to the Western College of Veterinary Medicine between 1996 and 2003 for evaluation of femoral fractures. There were three alpacas and two llamas. Four of the animals were female and three were less than 3 months of age. Fracture configurations consisted of distal physeal fractures (three), a comminuted diaphyseal/metaphyseal fracture, and a transverse diaphyseal fracture. Fractures were diagnosed with a combination of physical examination and radiographs in all cases. All five fractures were repaired with internal fixation and three animals were discharged from the hospital with fractures that healed. One cria underwent successful internal fixation but died from pulmonary oedema during recovery from anaesthesia. Postoperative complications were rare and limited to inadequate fracture stability in one alpaca and prolonged recovery to weight bearing in another. One llama with a comminuted metaphyseal fracture, repaired with a 4.5 mm dynamic compression plate, subsequently had catastrophic failure of the bone 17 days after surgery. Overall the clients were pleased with the outcome of discharged animals. Although femoral fractures are considered rare, they pose a unique opportunity for the large animal veterinarian to successfully achieve fracture union with the aid of internal fixation.
Holzer, Timothy R; Fulford, Angie D; Arkins, Austin M; Grondin, Janet M; Mundy, Christopher W; Nasir, Aejaz; Schade, Andrew E
2011-06-01
Post-translational modifications of proteins, such as phosphorylation, are labile events dynamically regulated by opposing kinase and phosphatase activities. Preanalytical factors, such as ischemic time before fixation, affect these activities and can have a significant impact on the ability to elucidate signaling pathways in tissue. Immunohistochemical analysis of phosphorylated proteins involved in PI3K/Akt, Erk/MAPK, and p38 MAPK signaling networks was performed in human cell line xenografts from lung, brain, ovary, and prostate tumors. In order to replicate real-world practices, the tissues were subjected to ischemic times of 0 (baseline), 1, 4, and 24 hours before fixation in formalin. Two key concepts emerge from this analysis: (1) the stability of different phospho-epitopes within a given tumor type is variable (e.g. phospho-PRAS40 is more labile than phospho-S6 ribosomal protein) and (2) the stability of a given phospho-epitope (e.g. phospho-MAPKAPK2) varies significantly across different tumor types. These results highlight the importance of proper tissue acquisition and rapid fixation to preserve the biological integrity of signal transduction pathways that may guide therapeutic decision making.
NASA Astrophysics Data System (ADS)
Cai, X.; Yang, Z.-L.; Fisher, J. B.; Zhang, X.; Barlage, M.; Chen, F.
2016-01-01
Climate and terrestrial biosphere models consider nitrogen an important factor in limiting plant carbon uptake, while operational environmental models view nitrogen as the leading pollutant causing eutrophication in water bodies. The community Noah land surface model with multi-parameterization options (Noah-MP) is unique in that it is the next-generation land surface model for the Weather Research and Forecasting meteorological model and for the operational weather/climate models in the National Centers for Environmental Prediction. In this study, we add a capability to Noah-MP to simulate nitrogen dynamics by coupling the Fixation and Uptake of Nitrogen (FUN) plant model and the Soil and Water Assessment Tool (SWAT) soil nitrogen dynamics. This model development incorporates FUN's state-of-the-art concept of carbon cost theory and SWAT's strength in representing the impacts of agricultural management on the nitrogen cycle. Parameterizations for direct root and mycorrhizal-associated nitrogen uptake, leaf retranslocation, and symbiotic biological nitrogen fixation are employed from FUN, while parameterizations for nitrogen mineralization, nitrification, immobilization, volatilization, atmospheric deposition, and leaching are based on SWAT. The coupled model is then evaluated at the Kellogg Biological Station - a Long Term Ecological Research site within the US Corn Belt. Results show that the model performs well in capturing the major nitrogen state/flux variables (e.g., soil nitrate and nitrate leaching). Furthermore, the addition of nitrogen dynamics improves the modeling of net primary productivity and evapotranspiration. The model improvement is expected to advance the capability of Noah-MP to simultaneously predict weather and water quality in fully coupled Earth system models.
Calvo, Manuel G; Nummenmaa, Lauri
2009-12-01
Happy, surprised, disgusted, angry, sad, fearful, and neutral faces were presented extrafoveally, with fixations on faces allowed or not. The faces were preceded by a cue word that designated the face to be saccaded in a two-alternative forced-choice discrimination task (2AFC; Experiments 1 and 2), or were followed by a probe word for recognition (Experiment 3). Eye tracking was used to decompose the recognition process into stages. Relative to the other expressions, happy faces (1) were identified faster (as early as 160 msec from stimulus onset) in extrafoveal vision, as revealed by shorter saccade latencies in the 2AFC task; (2) required less encoding effort, as indexed by shorter first fixations and dwell times; and (3) required less decision-making effort, as indicated by fewer refixations on the face after the recognition probe was presented. This reveals a happy-face identification advantage both prior to and during overt attentional processing. The results are discussed in relation to prior neurophysiological findings on latencies in facial expression recognition.
USDA-ARS?s Scientific Manuscript database
2-DE analysis of complex plant proteomes has limited dynamic resolution because only abundant proteins can be detected. Proteomic assessment of the low abundance proteins within leaf tissue is difficult when it is comprised of 30 – 50% of the CO2 fixation enzyme Rubisco. Resolution can be improved t...
Estimation of divergence from Hardy-Weinberg form.
Stark, Alan E
2015-08-01
The Hardy–Weinberg (HW) principle explains how random mating (RM) can produce and maintain a population in equilibrium, that is, with constant genotypic proportions. When proportions diverge from HW form, it is of interest to estimate the fixation index F, which reflects the degree of divergence. Starting from a sample of genotypic counts, a mixed procedure gives first the orthodox estimate of gene frequency q and then a Bayesian estimate of F, based on a credible prior distribution of F, which is described here.
Nitrogen cycling during secondary succession in Atlantic Forest of Bahia, Brazil.
Winbourne, Joy B; Feng, Aida; Reynolds, Lovinia; Piotto, Daniel; Hastings, Meredith G; Porder, Stephen
2018-01-22
Carbon accumulation in tropical secondary forests may be limited in part by nitrogen (N) availability, but changes in N during tropical forest succession have rarely been quantified. We explored N cycle dynamics across a chronosequence of secondary tropical forests in the Mata Atlântica of Bahia, Brazil in order to understand how quickly the N cycle recuperates. We hypothesized that N fixation would decline over the course of succession as N availability and N gaseous losses increased. We measured N fixation, KCl-extractable N, net mineralization and nitrification, resin-strip sorbed N, gaseous N emissions and the soil δ 15 N in stands that were 20, 35, 50, and > 50 years old. Contrary to our initial hypothesis, we found no significant differences between stand ages in any measured variable. Our findings suggest that secondary forests in this region of the Atlantic forest reached pre-disturbance N cycling dynamics after just 20 years of succession. This result contrasts with previous study in the Amazon, where the N cycle recovered slowly after abandonment from pasture reaching pre-disturbance N cycling levels after ~50 years of succession. Our results suggest the pace of the N cycle, and perhaps tropical secondary forest, recovery, may vary regionally.
Crosnier, Emilie A; Keogh, Patrick S; Miles, Anthony W
2016-08-01
The hip joint is subjected to cyclic loading and motion during activities of daily living and this can induce micromotions at the bone-implant interface of cementless total hip replacements. Initial stability has been identified as a crucial factor to achieve osseointegration and long-term survival. Whilst fixation of femoral stems achieves good clinical results, the fixation of acetabular components remains a challenge. In vitro methods assessing cup stability keep the hip joint in a fixed position, overlooking the effect of hip motion. The effect of hip motion on cup micromotion using a hip motion simulator replicating hip flexion-extension and a six degrees of freedom measurement system was investigated. The results show an increase in cup micromotion under dynamic hip motion compared to Static Flexion. This highlights the need to incorporate hip motion and measure all degrees of freedom when assessing cup micromotion. In addition, comparison of two press-fit acetabular cups with different surface coatings suggested similar stability between the two cups. This new method provides a basis for a more representative protocol for future pre-clinical evaluation of different cup designs. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
A study of the dynamics of multi-player games on small networks using territorial interactions.
Broom, Mark; Lafaye, Charlotte; Pattni, Karan; Rychtář, Jan
2015-12-01
Recently, the study of structured populations using models of evolutionary processes on graphs has begun to incorporate a more general type of interaction between individuals, allowing multi-player games to be played among the population. In this paper, we develop a birth-death dynamics for use in such models and consider the evolution of populations for special cases of very small graphs where we can easily identify all of the population states and carry out exact analyses. To do so, we study two multi-player games, a Hawk-Dove game and a public goods game. Our focus is on finding the fixation probability of an individual from one type, cooperator or defector in the case of the public goods game, within a population of the other type. We compare this value for both games on several graphs under different parameter values and assumptions, and identify some interesting general features of our model. In particular there is a very close relationship between the fixation probability and the mean temperature, with high temperatures helping fitter individuals and punishing unfit ones and so enhancing selection, whereas low temperatures give a levelling effect which suppresses selection.
NASA Technical Reports Server (NTRS)
Angelaki, D. E.; McHenry, M. Q.; Hess, B. J.
2000-01-01
The dynamics and three-dimensional (3-D) properties of the primate translational vestibuloocular reflex (trVOR) for high-frequency (4-12 Hz, +/-0.3-0.4 g) lateral motion were investigated during near-target viewing at center and eccentric targets. Horizontal response gains increased with frequency and depended on target eccentricity. The larger the horizontal and vertical target eccentricity, the steeper the dependence of horizontal response gain on frequency. In addition to horizontal eye movements, robust torsional response components also were present at all frequencies. During center-target fixation, torsional response phase was opposite (anticompensatory) to that expected for an "apparent" tilt response. Instead torsional response components depended systematically on vertical-target eccentricity, increasing in amplitude when looking down and reversing phase when looking up. As a result the trVOR eye velocity vector systematically tilted away from a purely horizontal direction, through an angle that increased with vertical eccentricity with a slope of approximately 0.7. This systematic dependence of torsional eye velocity tilt on vertical eye position suggests that the trVOR might follow the 3-D kinematic requirements that have been shown to govern visually guided eye movements and near-target fixation.
Toda, Y
2001-06-01
We assessed the clinical efficacy of a lateral wedged insole with elastic fixation of the subtalar joint for conservative treatment of osteoarthritis of the knee. Novel insoles with elastic subtalar fixation (fixed insole) and a traditional shoe insert wedged insoles (inserted insole) were prepared. Seventy-one new female outpatients with osteoarthritis of the knee (knee OA) were treated with wedged insoles for 3 months. Randomization was performed according to birth date. The Severity Index of Lequesne, et al at the final assessment was compared with that at baseline in both the inserted and fixed insole groups. There were 37 participants in the inserted group and 34 participants in the fixed insole group. Regarding discomfort during nocturnal bed rest, 21 out of 34 (61%) participants were positive at the baseline assessment, however, only 8 out of 34 (27%) were positive at the final assessment in the fixed insole group (P = 0.033). In the fixed insole group, the number of participants complained immediate pain after walking was decreased from 28 (82%) at the baseline assessment to 17 (50%) at the final assessments (P = 0.0104). These significant differences were not found in the group with the inserted insole. Thus, clinical efficacy of lateral wedged insole may be emphasized with elastic fixation of the subtalar joint.
Limb lengthening in short-stature patients using monolateral and circular external fixators.
Lie, Chester W H; Chow, W
2009-08-01
To review the results of distraction osteogenesis in short-stature patients in our centre and analyse outcomes including complications. Retrospective study. University teaching hospital, Hong Kong. Eight patients with short stature (three had achondroplasia, three constitutional short stature, and two hypochondroplasia) operated on for limb lengthening using monolateral or circular external fixators between 1995 and 2006 were reviewed. The mean age at the time of surgery was 20 years (range, 9-39 years). The fixators used were either Ilizarov or Orthofix. The average gain in length per bone segment was 5.2 cm (range, 3.2-8.0 cm), and the average percentage lengthening was 21% (range, 7.9-40%). The mean time in frame was 8 months (range, 4-14 months), and the average healing index was 48 days per cm of lengthening (18-110 days per cm). Minor complications (pin tract infection and transient joint stiffness) were common, and after excluding the latter the overall complication rate was 0.6 per bone segment. In our series, limb lengthening of up to 40% of the initial length of the bone segment can be achieved without significant long-term sequelae. However, the procedures were complex and prolonged, and required a special psychological approach directed at both parents and the patients. Complications are quite common, for which patients have to be well prepared before starting the procedures.
Naicker, Preshanta; Anoopkumar-Dukie, Shailendra; Grant, Gary D; Modenese, Luca; Kavanagh, Justin J
2017-02-01
Anticholinergic medications largely exert their effects due to actions on the muscarinic receptor, which mediates the functions of acetylcholine in the peripheral and central nervous systems. In the central nervous system, acetylcholine plays an important role in the modulation of movement. This study investigated the effects of over-the-counter medications with varying degrees of central anticholinergic properties on fixation stability, saccadic response time and the dynamics associated with this eye movement during a temporally-cued visual reaction time task, in order to establish the significance of central cholinergic pathways in influencing eye movements during reaction time tasks. Twenty-two participants were recruited into the placebo-controlled, human double-blind, four-way crossover investigation. Eye tracking technology recorded eye movements while participants reacted to visual stimuli following temporally informative and uninformative cues. The task was performed pre-ingestion as well as 0.5 and 2 h post-ingestion of promethazine hydrochloride (strong centrally acting anticholinergic), hyoscine hydrobromide (moderate centrally acting anticholinergic), hyoscine butylbromide (anticholinergic devoid of central properties) and a placebo. Promethazine decreased fixation stability during the reaction time task. In addition, promethazine was the only drug to increase saccadic response time during temporally informative and uninformative cued trials, whereby effects on response time were more pronounced following temporally informative cues. Promethazine also decreased saccadic amplitude and increased saccadic duration during the temporally-cued reaction time task. Collectively, the results of the study highlight the significant role that central cholinergic pathways play in the control of eye movements during tasks that involve stimulus identification and motor responses following temporal cues.
Pohlemann, Tim; Gueorguiev, Boyko; Agarwal, Yash; Wahl, Dieter; Sprecher, Christoph; Schwieger, Karsten; Lenz, Mark
2015-04-01
The novel dynamic locking screw (DLS) was developed to improve bone healing with locked-plate osteosynthesis by equalising construct stiffness at both cortices. Due to a theoretical damping effect, this modulated stiffness could be beneficial for fracture fixation in osteoporotic bone. Therefore, the mechanical behaviour of the DLS at the screw-bone interface was investigated in an artificial osteoporotic bone model and compared with conventional locking screws (LHS). Osteoporotic surrogate bones were plated with either a DLS or a LHS construct consisting of two screws and cyclically axially loaded (8,500 cycles, amplitude 420 N, increase 2 mN/cycle). Construct stiffness, relative movement, axial screw migration, proximal (P) and distal (D) screw pullout force and loosening at the bone interface were determined and statistically evaluated. DLS constructs exhibited a higher screw pullout force of P 85 N [standard deviation (SD) 21] and D 93 N (SD 12) compared with LHS (P 62 N, SD 28, p = 0.1; D 57 N, SD 25, p < 0.01) and a significantly lower axial migration over cycles compared with LHS (p = 0.01). DLS constructs showed significantly lower axial construct stiffness (403 N/mm, SD 21, p < 0.01) and a significantly higher relative movement (1.1 mm, SD 0.05, p < 0.01) compared with LHS (529 N/mm, SD 27; 0.8 mm, SD 0.04). Based on the model data, the DLS principle might also improve in vivo plate fixation in osteoporotic bone, providing enhanced residual holding strength and reducing screw cutout. The influence of pin-sleeve abutment still needs to be investigated.
Pfau, Maximilian; Lindner, Moritz; Müller, Philipp L; Birtel, Johannes; Finger, Robert P; Harmening, Wolf M; Fleckenstein, Monika; Holz, Frank G; Schmitz-Valckenberg, Steffen
2017-05-01
To determine the effective dynamic range (EDR), retest reliability, and number of discriminable steps (DS) for mesopic and dark-adapted two-color fundus-controlled perimetry (FCP) using the S-MAIA (Scotopic-Macular Integrity Assessment) "micro-perimeter." In this prospective cross-sectional study, each of the 52 eyes of 52 subjects with various macular diseases (mean age 62.0 ± 16.9 years; range, 19.1-90.1 years) underwent duplicate mesopic (achromatic stimuli, 400-800 nm), dark-adapted cyan (505 nm), and dark-adapted red (627 nm) FCP using a grid of 61 stimuli covering 18° of the central retina. The EDR, the number of DS, and the retest reliability for point-wise sensitivity (PWS) were analyzed. The effects of fixation stability, sensitivity, and age on retest reliability were examined using mixed-effects models. The EDR was 10 to 30 dB with five DS for mesopic and 4 to 17 dB with four DS for dark-adapted cyan and red testing. PWS retest reliability was good among all three types of retinal sensitivity assessments (coefficient of repeatability ±5.79, ±4.72, and ±4.77 dB, respectively) and did not depend on fixation stability or age. PWS had no effect on retest variability in dark-adapted cyan and dark-adapted red testing but had a minor effect in mesopic testing. Combined mesopic and dark-adapted two-color FCP allows for reliable topographic testing of cone and rod function in patients with various macular diseases with and without foveal fixation. Retest reliability is homogeneous across eccentricities and various degrees of scotoma depth, including zones at risk for disease progression. These reliability estimates can serve for the design of future clinical trials.
Celler, Katherine; Fujita, Miki; Kawamura, Eiko; Ambrose, Chris; Herburger, Klaus; Wasteneys, Geoffrey O.
2016-01-01
Microtubules are required throughout plant development for a wide variety of processes, and different strategies have evolved to visualize and analyze them. This chapter provides specific methods that can be used to analyze microtubule organization and dynamic properties in plant systems and summarizes the advantages and limitations for each technique. We outline basic methods for preparing samples for immunofluorescence labelling, including an enzyme-based permeabilization method, and a freeze-shattering method, which generates microfractures in the cell wall to provide antibodies access to cells in cuticle-laden aerial organs such as leaves. We discuss current options for live cell imaging of MTs with fluorescently tagged proteins (FPs), and provide chemical fixation, high pressure freezing/freeze substitution, and post-fixation staining protocols for preserving MTs for transmission electron microscopy and tomography. PMID:26498784
Müller, Nico; Baumeister, Sarah; Dziobek, Isabel; Banaschewski, Tobias; Poustka, Luise
2016-09-01
Impaired social cognition is one of the core characteristics of autism spectrum disorders (ASD). Appropriate measures of social cognition for high-functioning adolescents with ASD are, however, lacking. The Movie for the Assessment of Social Cognition (MASC) uses dynamic social stimuli, ensuring ecological validity, and has proven to be a sensitive measure in adulthood. In the current study, 33 adolescents with ASD and 23 controls were administered the MASC, while concurrent eye tracking was used to relate gaze behavior to performance levels. The ASD group exhibited reduced MASC scores, with social cognition performance being explained by shorter fixation duration on eyes and decreased pupil dilation. These potential diagnostic markers are discussed as indicators of different processing of social information in ASD.
Raghunath, M; Singh, N; Singh, T; Gopinathan, A; Mohindroo, J; Atri, K
2013-01-01
A two-and-half-year-old cow was presented with a defect nonunion of the right metatarsal III/IV bone following a severely comminuted open fracture two months previously. The animal underwent open fixation using a 4.5 mm, broad, 10-hole, dynamic compression plate and autogenous cancellous bone graft collected from the contralateral iliac shaft. The animal started partial weight bearing after the third postoperative day and resumed complete weight bearing after the 10th day. Fracture healing was complete and the implants were removed after the 120th postoperative day. Stable fixation by means of a bone plate in conjunction with a cancellous bone graft facilitated complete healing and restoration of the bone column of the defect and the metatarsal fracture. The animal made a complete recovery.
Cytochemical Detection of Peroxisomes in Light and Electron Microscopy with 3,3'-diaminobenzidine.
Fahimi, H Dariush
2017-01-01
Peroxisomes are ubiquitous dynamic and multifunctional organelles that contribute to numerous anabolic and catabolic pathways, being essential for human health and development. Their best known functions include the oxidation of fatty acids and metabolism of hydrogen peroxide with catalase as a marker enzyme. Indeed, historically, it was the cytochemical staining of catalase in many different cells and tissues that revealed the ubiquitous presence of peroxisomes in almost all animal and plant cells. In this chapter, the method for cytochemical staining of catalase with the alkaline 3, 3'-diaminobenzidine (DAB) is described. Since aldehyde fixation is a prerequisite for staining of catalase with DAB, a method for perfusion fixation of rat liver with glutaraldehyde is presented prior to the cytochemical staining method and the subsequent tissue processing for light and electron microscopy.
Zhang, Zhi-Da; Ye, Xiu-Yi; Shang, Li-Yong; Xu, Rong-Ming; Zhu, Yan-Zhao
2011-12-01
To explore the clinical efficacy of delayed open reduction and internal fixation with minimally invasive percutaneous locking compression plate for the treatment of type II and III Pilon fractures. From January 2007 to September 2009, 32 patients with type II and III Pilon fractures were treated with open reduction and anatomic plate fixation (AP group) and minimally invasive percutaneous locking compression plate osteosynthesis (LCP group). There were 11 males and 6 females in AP group, with an average age of (37.4 +/- 13.3) years (ranged, 19 to 55 years). And there were 10 males and 5 females in LCP group, with an average age of (34.6 +/- 11.3) years(ranged, 21 to 56 years). The operating time, fracture healing time, aligned angulation and ankle function were compared between the two groups. All the patients were followed up, and the during ranged from 12 to 25 months, with a mean of (15.0 +/- 1.7) months. The average operation time was (76.5 +/- 8.3) min for AP group and (58.3 +/- 3.4) min for LCP group; the average time of fracture healing was (20.5 +/- 0.4) weeks for AP group and (15.7 +/- 0.2) weeks for LCP group; the total angulation between anterior posterior film and lateral film was averaged (6.6 +/- 0.5) degrees for AP group and (3.6 +/- 0.2) degrees for LCP group. As to above index, the results of LCP group were better than those of AP group (P < 0.05). According to Kofoed criteria for ankle joint, the results of LCP group were better than those of AP group in ankle joint pain, wakling and ankle joint function (P < 0.05). The method of minimally invasive percutaneous locking compression plate internal fixation is effective in the treatment of Pilon fracture with less invasion, faster bone union, more stabilized fixation, quicker recovery of ankle function and fewer complications, which is more advantaged for type II and III Pilon fractures.
Malham, Gregory M; Ellis, Ngaire J; Parker, Rhiannon M; Blecher, Carl M; White, Rohan; Goss, Ben; Seex, Kevin A
2017-03-01
A prospective single-surgeon nonrandomized clinical study. To evaluate the radiographic and clinical outcomes, by fixation type, in extreme lateral interbody fusion (XLIF) patients and provide an algorithm for determining patients suitable for stand-alone XLIF. XLIF may be supplemented with pedicle screw fixation, however, since stabilizing structures remain intact, it is suggested that stand-alone XLIF can be used for certain indications. This eliminates the associated morbidity, though subsidence rates may be elevated, potentially minimizing the clinical benefits. A fixation algorithm was developed after evaluation of patient outcomes from the surgeon's first 30 cases. This algorithm was used prospectively for 40 subsequent patients to determine the requirement for supplemental fixation. Preoperative, postoperative, and 12-month follow-up computed tomography scans were measured for segmental and global lumbar lordosis and posterior disk height. Clinical outcome measures included back and leg pain (visual analogue scale), Oswestry Disability Index (ODI), and SF-36 physical and mental component scores (PCS and MCS). Preoperatively to 12-month follow-up there were increases in segmental lordosis (7.9-9.4 degrees, P=0.0497), lumbar lordosis (48.8-55.2 degrees, P=0.0328), and disk height (3.7-5.5 mm, P=0.0018); there were also improvements in back (58.6%) and leg pain (60.0%), ODI (44.4%), PCS (56.7%), and MCS (16.1%) for stand-alone XLIF. For instrumented XLIF, segmental lordosis (7.6-10.5 degrees, P=0.0120) and disk height (3.5-5.6 mm, P<0.001) increased, while lumbar lordosis decreased (51.1-45.8 degrees, P=0.2560). Back (49.8%) and leg pain (30.8%), ODI (32.3%), PCS (37.4%), and MCS (2.0%) were all improved. Subsidence occurred in 3 (7.5%) stand-alone patients. The XLIF treatment fixation algorithm provided a clinical pathway to select suitable patients for stand-alone XLIF. These patients achieved positive clinical outcomes, satisfactory fusion rates, with sustained correction of lordosis and restoration of disk height.
Song, Geun Soo; Lee, Yeon Soo
2015-07-01
This study aimed to quantify morphological characteristics of the posterior lumbar spinous process, which may affect stable implantation of screwless wire spring loops. Virtual implantations of a screwless wire spring loop onto pairs of lumbar spinous processes were performed for computed tomography (CT)-derived three-dimensional vertebral models of 40 Korean subjects. Morphological parameters of lumbar vertebrae 1 through 5 (L1-L5) were measured with regard to bone-implant interference. In males, the transspinous process fixation lengths decreased from 57.8±3.0mm to 48.8±3.2mm as the lumbar joints descend from L1-L2 to L4-L5, with those in females about 4.1±0.4mm shorter (p<0.05) than in males through all lumbar joints. The fixation angle on the sagittal plane varied from 105.0° to 101.3° relative to the transverse plane as the vertebrae descend. The clenched thickness in females was the least (6.7±1.2mm) for the L2 lower spinous process and the greatest (8.1±2.2mm) for the L4 upper spinous process; this was 1.0±10.3mm less than that for males at corresponding levels (p>0.05). The ratio of the spinous process clenched thickness to the transspinous fixation length increased from 0.133±0.016 to 0.196±0.076 for the upper spinous processes as the lumbar joints descend. The ratio of the spinous process clenched thickness to the transspinous fixation length varies, depending on gender and whether the clenched level is the upper or lower spinous process. These parameters related to the clenching fixation stability should be considered in development and implantations of the screwless wire spring loop. Copyright © 2015 Elsevier GmbH. All rights reserved.
NASA Astrophysics Data System (ADS)
Arroniz-Crespo, Maria; Jones, David L.; Zackrisson, Olle; Nilsson, Marie-Charlotte; DeLuca, Thomas H.
2014-05-01
Biological N2 fixation by cyanobacteria associated with feather mosses is an important cog in the nitrogen (N) cycle of boreal forests; still, our understanding of the turnover and fate of N fixed by this association remains greatly incomplete. The 15N signature of plants and soil serves as a powerful tool to explore N dynamics in forest ecosystems. In particular, in the present study we aimed to investigate the contribution of N2 fixation to δ15N signatures of plants and humus component of the boreal forest. Here we present results from a long-term (7 years) tacking of labelled 15N2 across the humus layer, seedlings of the tree species Pinus sylvestris, two common dwarf shrub species (Empetrum hermaphroditum and Vaccinium vitis-idaea) and the feather moss Pleurozium schreibery. The enriched experiment was conducted in 2005 in a natural boreal forest in northern Sweden. Two different treatments (10% 15N2 headspace enrichment and control) were setup in nine different plots (0.5 x 0.5 m) within the forest. We observed a significant reduction of δ15N signature of the 15N-enriched moss that could be explained by a growth dilution effect. Nevertheless, after 5 years since 15N2 enrichment some of the label 15N was still detected on the moss and in particular in the dead tissue. We could not detect a clear transfer of the labelled 15N2 from the moss-cyanobacteria system to other components of the ecosystem. However, we found consistence relationship through time between increments of δ15N signature of some of the forest components in plots which exhibited higher N fixation rates in the moss. In particular, changes in natural abundance δ15N that could be associated with N fixation were more apparent in the humus layer, the dwarf shrub Vaccinium vitis-idaea and the pine seedlings when comparing across plots and years.
Drivers of the dynamics of diazotrophs and denitrifiers in North Sea bottom waters and sediments
Fan, Haoxin; Bolhuis, Henk; Stal, Lucas J.
2015-01-01
The fixation of dinitrogen (N2) and denitrification are two opposite processes in the nitrogen cycle. The former transfers atmospheric dinitrogen gas into bound nitrogen in the biosphere, while the latter returns this bound nitrogen back to atmospheric dinitrogen. It is unclear whether or not these processes are intimately connected in any microbial ecosystem or that they are spatially and/or temporally separated. Here, we measured seafloor nitrogen fixation and denitrification as well as pelagic nitrogen fixation by using the stable isotope technique. Alongside, we measured the diversity, abundance, and activity of nitrogen-fixing and denitrifying microorganisms at three stations in the southern North Sea. Nitrogen fixation ranged from undetectable to 2.4 nmol N L−1 d−1 and from undetectable to 8.2 nmol N g−1 d−1 in the water column and seafloor, respectively. The highest rates were measured in August at Doggersbank, both for the water column and for the seafloor. Denitrification ranged from 1.7 to 208.8 μmol m−2 d−1 and the highest rates were measured in May at the Oyster Grounds. DNA sequence analysis showed sequences of nifH, a structural gene for nitrogenase, related to sequences from anaerobic sulfur/iron reducers and sulfate reducers. Sequences of the structural gene for nitrite reductase, nirS, were related to environmental clones from marine sediments. Quantitative polymerase chain reaction (qPCR) data revealed the highest abundance of nifH and nirS genes at the Oyster Grounds. Quantitative reverse transcription polymerase chain reaction (qRT-PCR) data revealed the highest nifH expression at Doggersbank and the highest nirS expression at the Oyster Grounds. The distribution of the diazotrophic and denitrifying communities seems to be subject to different selecting factors, leading to spatial and temporal separation of nitrogen fixation and denitrification. These selecting factors include temperature, organic matter availability, and oxygen concentration. PMID:26257718
ERIC Educational Resources Information Center
Müller, Nico; Baumeister, Sarah; Dziobek, Isabel; Banaschewski, Tobias; Poustka, Luise
2016-01-01
Impaired social cognition is one of the core characteristics of autism spectrum disorders (ASD). Appropriate measures of social cognition for high-functioning adolescents with ASD are, however, lacking. The Movie for the Assessment of Social Cognition (MASC) uses dynamic social stimuli, ensuring ecological validity, and has proven to be a…
Insights into numerical cognition: considering eye-fixations in number processing and arithmetic.
Mock, J; Huber, S; Klein, E; Moeller, K
2016-05-01
Considering eye-fixation behavior is standard in reading research to investigate underlying cognitive processes. However, in numerical cognition research eye-tracking is used less often and less systematically. Nevertheless, we identified over 40 studies on this topic from the last 40 years with an increase of eye-tracking studies on numerical cognition during the last decade. Here, we review and discuss these empirical studies to evaluate the added value of eye-tracking for the investigation of number processing. Our literature review revealed that the way eye-fixation behavior is considered in numerical cognition research ranges from investigating basic perceptual aspects of processing non-symbolic and symbolic numbers, over assessing the common representational space of numbers and space, to evaluating the influence of characteristics of the base-10 place-value structure of Arabic numbers and executive control on number processing. Apart from basic results such as reading times of numbers increasing with their magnitude, studies revealed that number processing can influence domain-general processes such as attention shifting-but also the other way round. Domain-general processes such as cognitive control were found to affect number processing. In summary, eye-fixation behavior allows for new insights into both domain-specific and domain-general processes involved in number processing. Based thereon, a processing model of the temporal dynamics of numerical cognition is postulated, which distinguishes an early stage of stimulus-driven bottom-up processing from later more top-down controlled stages. Furthermore, perspectives for eye-tracking research in numerical cognition are discussed to emphasize the potential of this methodology for advancing our understanding of numerical cognition.
Vigdorchik, Jonathan M; Esquivel, Amanda O; Jin, Xin; Yang, King H; Onwudiwe, Ndidi A; Vaidya, Rahul
2012-09-27
We have recently developed a subcutaneous anterior pelvic fixation technique (INFIX). This internal fixator permits patients to sit, roll over in bed and lie on their sides without the cumbersome external appliances or their complications. The purpose of this study was to evaluate the biomechanical stability of this novel supraacetabular pedicle screw internal fixation construct (INFIX) and compare it to standard internal fixation and external fixation techniques in a single stance pelvic fracture model. Nine synthetic pelves with a simulated anterior posterior compression type III injury were placed into three groups (External Fixator, INFIX and Internal Fixation). Displacement, total axial stiffness, and the stiffness at the pubic symphysis and SI joint were calculated. Displacement and stiffness were compared by ANOVA with a Bonferroni adjustment for multiple comparisons The mean displacement at the pubic symphysis was 20, 9 and 0.8 mm for external fixation, INFIX and internal fixation, respectively. Plate fixation was significantly stiffer than the INFIX and external Fixator (P = 0.01) at the symphysis pubis. The INFIX device was significantly stiffer than external fixation (P = 0.017) at the symphysis pubis. There was no significant difference in SI joint displacement between any of the groups. Anterior plate fixation is stiffer than both the INFIX and external fixation in single stance pelvic fracture model. The INFIX was stiffer than external fixation for both overall axial stiffness, and stiffness at the pubic symphysis. Combined with the presumed benefit of minimizing the complications associated with external fixation, the INFIX may be a more preferable option for temporary anterior pelvic fixation in situations where external fixation may have otherwise been used.
Wiater, Brett P; Moravek, James E; Kurdziel, Michael D; Baker, Kevin C; Wiater, J Michael
2016-01-01
Newer glenoid components that allow for hybrid cement fixation via traditional cementation of peripheral pegs and bony ingrowth into an interference-fit central peg introduce the possibility of long-term biological fixation. However, little biomechanical work has been done on the initial stability of these components and the various fixation options. We conducted a study in which all-polyethylene glenoid components with a centrally fluted peg were implanted in polyurethane blocks with interference-fit, hybrid cement, and fully cemented fixation (5 per fixation group). Biomechanical evaluation of glenoid loosening, according to ASTM Standard F-2028-12, subjected the glenoids to 50,000 cycles of rim loading, and glenoid component motion was recorded with 2 differential variable reluctance transducers fixed to each glenoid prosthesis. Fully cemented fixation exhibited significantly less mean distraction in comparison with interference-fit fixation (P < .001) and hybrid cement fixation (P < .001). Hybrid cement fixation exhibited significantly less distraction (P < .001), more compression (P < .001), and no significant difference in glenoid translation (P = .793) in comparison with interference-fit fixation. Fully cemented fixation exhibited the most resistance to glenoid motion in comparison with hybrid cement fixation and interference-fit fixation. However, hybrid cement fixation and interference-fit fixation exhibited equivocal motion. Given these results, cementation of peripheral pegs may confer no additional initial stability over that provided by uncemented interference-fit fixation.
NASA Astrophysics Data System (ADS)
Pfreundt, Ulrike; Van Wambeke, France; Caffin, Mathieu; Bonnet, Sophie; Hess, Wolfgang R.
2016-04-01
N2 fixation fuels ˜ 50 % of new primary production in the oligotrophic South Pacific Ocean. The VAHINE experiment has been designed to track the fate of diazotroph-derived nitrogen (DDN) and carbon within a coastal lagoon ecosystem in a comprehensive way. For this, large-volume ( ˜ 50 m3) mesocosms were deployed in the New Caledonian lagoon and were intentionally fertilized with dissolved inorganic phosphorus (DIP) to stimulate N2 fixation. This study examined the temporal dynamics of the prokaryotic community together with the evolution of biogeochemical parameters for 23 consecutive days in one of these mesocosms (M1) and in the Nouméa lagoon using MiSeq 16S rRNA gene sequencing and flow cytometry. Combining these methods allowed for inference of absolute cell numbers from 16S data. We observed clear successions within M1, some of which were not mirrored in the lagoon. The dominating classes in M1 were Alpha- and Gammaproteobacteria, Cyanobacteria, eukaryotic microalgae, Marine Group II Euryarchaeota, Flavobacteriia, and Acidimicrobia. Enclosure led to significant changes in the M1 microbial community, probably initiated by the early decay of Synechococcus and diatoms. However, we did not detect a pronounced bottle effect with a copiotroph-dominated community. The fertilization with ˜ 0.8 µM DIP on day 4 did not have directly observable effects on the overall community within M1, as the data samples obtained from before and 4 days after fertilization clustered together, but likely influenced the development of individual populations later on, like Defluviicoccus-related bacteria and UCYN-C-type diazotrophic cyanobacteria (Cyanothece). Growth of UCYN-C led to among the highest N2-fixation rates ever measured in this region and enhanced growth of nearly all abundant heterotrophic groups in M1. We further show that different Rhodobacteraceae were the most efficient heterotrophs in the investigated system and we observed niche partitioning within the SAR86 clade. Whereas the location in- or outside the mesocosm had a significant effect on community composition, the temporal effect was significantly stronger and similar in both locations, suggesting that overarching abiotic factors were more influential than the enclosure. While temporal community changes were evident, prokaryotic diversity (Shannon index) only declined slightly from ˜ 6.5 to 5.7 or 6.05 in the lagoon and M1, respectively, throughout the experiment, highlighting the importance of multiple and varying sources of organic matter maintaining competition.
Evolutionary Dynamics of Nitrogen Fixation in the Legume–Rhizobia Symbiosis
Fujita, Hironori; Aoki, Seishiro; Kawaguchi, Masayoshi
2014-01-01
The stabilization of host–symbiont mutualism against the emergence of parasitic individuals is pivotal to the evolution of cooperation. One of the most famous symbioses occurs between legumes and their colonizing rhizobia, in which rhizobia extract nutrients (or benefits) from legume plants while supplying them with nitrogen resources produced by nitrogen fixation (or costs). Natural environments, however, are widely populated by ineffective rhizobia that extract benefits without paying costs and thus proliferate more efficiently than nitrogen-fixing cooperators. How and why this mutualism becomes stabilized and evolutionarily persists has been extensively discussed. To better understand the evolutionary dynamics of this symbiosis system, we construct a simple model based on the continuous snowdrift game with multiple interacting players. We investigate the model using adaptive dynamics and numerical simulations. We find that symbiotic evolution depends on the cost–benefit balance, and that cheaters widely emerge when the cost and benefit are similar in strength. In this scenario, the persistence of the symbiotic system is compatible with the presence of cheaters. This result suggests that the symbiotic relationship is robust to the emergence of cheaters, and may explain the prevalence of cheating rhizobia in nature. In addition, various stabilizing mechanisms, such as partner fidelity feedback, partner choice, and host sanction, can reinforce the symbiotic relationship by affecting the fitness of symbionts in various ways. This result suggests that the symbiotic relationship is cooperatively stabilized by various mechanisms. In addition, mixed nodule populations are thought to encourage cheater emergence, but our model predicts that, in certain situations, cheaters can disappear from such populations. These findings provide a theoretical basis of the evolutionary dynamics of legume–rhizobia symbioses, which is extendable to other single-host, multiple-colonizer systems. PMID:24691447
Cai, X.; Yang, Z. -L.; Fisher, J. B.; ...
2016-01-15
Climate and terrestrial biosphere models consider nitrogen an important factor in limiting plant carbon uptake, while operational environmental models view nitrogen as the leading pollutant causing eutrophication in water bodies. The community Noah land surface model with multi-parameterization options (Noah-MP) is unique in that it is the next-generation land surface model for the Weather Research and Forecasting meteorological model and for the operational weather/climate models in the National Centers for Environmental Prediction. Here in this study, we add a capability to Noah-MP to simulate nitrogen dynamics by coupling the Fixation and Uptake of Nitrogen (FUN) plant model and the Soilmore » and Water Assessment Tool (SWAT) soil nitrogen dynamics. This model development incorporates FUN's state-of-the-art concept of carbon cost theory and SWAT's strength in representing the impacts of agricultural management on the nitrogen cycle. Parameterizations for direct root and mycorrhizal-associated nitrogen uptake, leaf retranslocation, and symbiotic biological nitrogen fixation are employed from FUN, while parameterizations for nitrogen mineralization, nitrification, immobilization, volatilization, atmospheric deposition, and leaching are based on SWAT. The coupled model is then evaluated at the Kellogg Biological Station – a Long Term Ecological Research site within the US Corn Belt. Results show that the model performs well in capturing the major nitrogen state/flux variables (e.g., soil nitrate and nitrate leaching). Furthermore, the addition of nitrogen dynamics improves the modeling of net primary productivity and evapotranspiration. The model improvement is expected to advance the capability of Noah-MP to simultaneously predict weather and water quality in fully coupled Earth system models.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cai, X.; Yang, Z. -L.; Fisher, J. B.
Climate and terrestrial biosphere models consider nitrogen an important factor in limiting plant carbon uptake, while operational environmental models view nitrogen as the leading pollutant causing eutrophication in water bodies. The community Noah land surface model with multi-parameterization options (Noah-MP) is unique in that it is the next-generation land surface model for the Weather Research and Forecasting meteorological model and for the operational weather/climate models in the National Centers for Environmental Prediction. Here in this study, we add a capability to Noah-MP to simulate nitrogen dynamics by coupling the Fixation and Uptake of Nitrogen (FUN) plant model and the Soilmore » and Water Assessment Tool (SWAT) soil nitrogen dynamics. This model development incorporates FUN's state-of-the-art concept of carbon cost theory and SWAT's strength in representing the impacts of agricultural management on the nitrogen cycle. Parameterizations for direct root and mycorrhizal-associated nitrogen uptake, leaf retranslocation, and symbiotic biological nitrogen fixation are employed from FUN, while parameterizations for nitrogen mineralization, nitrification, immobilization, volatilization, atmospheric deposition, and leaching are based on SWAT. The coupled model is then evaluated at the Kellogg Biological Station – a Long Term Ecological Research site within the US Corn Belt. Results show that the model performs well in capturing the major nitrogen state/flux variables (e.g., soil nitrate and nitrate leaching). Furthermore, the addition of nitrogen dynamics improves the modeling of net primary productivity and evapotranspiration. The model improvement is expected to advance the capability of Noah-MP to simultaneously predict weather and water quality in fully coupled Earth system models.« less
Modeling the convergence accommodation of stereo vision for binocular endoscopy.
Gao, Yuanqian; Li, Jinhua; Li, Jianmin; Wang, Shuxin
2018-02-01
The stereo laparoscope is an important tool for achieving depth perception in robot-assisted minimally invasive surgery (MIS). A dynamic convergence accommodation algorithm is proposed to improve the viewing experience and achieve accurate depth perception. Based on the principle of the human vision system, a positional kinematic model of the binocular view system is established. The imaging plane pair is rectified to ensure that the two rectified virtual optical axes intersect at the fixation target to provide immersive depth perception. Stereo disparity was simulated with the roll and pitch movements of the binocular system. The chessboard test and the endoscopic peg transfer task were performed, and the results demonstrated the improved disparity distribution and robustness of the proposed convergence accommodation method with respect to the position of the fixation target. This method offers a new solution for effective depth perception with the stereo laparoscopes used in robot-assisted MIS. Copyright © 2017 John Wiley & Sons, Ltd.
Population Genetics in Compressible Flows
NASA Astrophysics Data System (ADS)
Pigolotti, Simone; Benzi, Roberto; Jensen, Mogens H.; Nelson, David R.
2012-03-01
We study competition between two biological species advected by a compressible velocity field. Individuals are treated as discrete Lagrangian particles that reproduce or die in a density-dependent fashion. In the absence of a velocity field and fitness advantage, number fluctuations lead to a coarsening dynamics typical of the stochastic Fisher equation. We investigate three examples of compressible advecting fields: a shell model of turbulence, a sinusoidal velocity field and a linear velocity sink. In all cases, advection leads to a striking drop in the fixation time, as well as a large reduction in the global carrying capacity. We find localization on convergence zones, and very rapid extinction compared to well-mixed populations. For a linear velocity sink, one finds a bimodal distribution of fixation times. The long-lived states in this case are demixed configurations with a single interface, whose location depends on the fitness advantage.
A conservative approach to pediatric mandibular fracture management: outcome and advantages.
Khatri, Amit; Kalra, Namita
2011-01-01
Pediatric mandibular fractures are rare and their treatment remains controversial. Management is extremely complicated in mixed dentition as it is inherently dynamic and unstable. Treatment options include soft diet, intermaxillary fixation with eyelet wires, arch bars, circummandibular wiring, or stents. Alternative options include open reduction and internal fixation through either an intraoral or extraoral approach. This case report describes and evaluates the conservative technique of acrylic splint in the treatment of pediatric mandible fracture in a 12-year-old female child. The patient with isolated mandibular fracture was treated with acrylic splint and interdental wiring followed by evaluation of clinical and radiographic healing as well as the somatosensory status. Patient demonstrated clinical union to her pre-injury occlusion by three to four weeks. Panoramic finding supported the finding of clinical examination throughout the study. High osteogenic potential of the pediatric mandible allowed conservative management to be successful in this case.
Can infants' orientation to social stimuli predict later joint attention skills?
Schietecatte, Inge; Roeyers, Herbert; Warreyn, Petra
2012-06-01
From the moment infants are born, they seem to prefer orienting to social stimuli, over objects and non-social stimuli. This preference lasts throughout adulthood and is believed to play a crucial role in social-communicative development. By following up a group of infants at the age of 6, 8, and 12 months, this study explored the role of social orienting in the early development of joint attention skills. The expected association between social orienting and joint attention was partially confirmed. Social orienting in real-life photographs of everyday situations was not related to later joint attention skills, however fixation to the eyes in a neutral face was related to response to joint attention skills, and fixation to the eyes in a dynamic video clip of a talking person was predictive of initiating joint attention skills. Several alternative interpretations of the results are discussed. ©2011 The British Psychological Society.
Biomechanical characteristics of fixation methods for floating pubic symphysis.
Song, Wenhao; Zhou, Dongsheng; He, Yu
2017-03-07
Floating pubic symphysis (FPS) is a relatively rare injury caused by high-energy mechanisms. There are several fixation methods used to treat FPS, including external fixation, subcutaneous fixation, internal fixation, and percutaneous cannulated screw fixation. To choose the appropriate fixation, it is necessary to study the biomechanical performance of these different methods. The goal of this study was to compare the biomechanical characteristics of six methods by finite element analysis. A three-dimensional finite element model of FPS was simulated. Six methods were used in the FPS model, including external fixation (Ext), subcutaneous rod fixation (Sub-rod), subcutaneous plate fixation (Sub-plate), superior pectineal plate fixation (Int-sup), infrapectineal plate fixation (Int-ifa), and cannulated screw fixation (Int-scr). Compressive and rotational loads were then applied in all models. Biomechanical characteristics that were recorded and analyzed included construct stiffness, micromotion of the fracture gaps, von Mises stress, and stress distribution. The construct stiffness of the anterior pelvic ring was decreased dramatically when FPS occurred. Compressive stiffness was restored by the three internal fixation and Sub-rod methods. Unfortunately, rotational stiffness was not restored satisfactorily by the six methods. For micromotion of the fracture gaps, the displacement was reduced significantly by the Int-sup and Int-ifa methods under compression. The internal fixation methods and Sub-plate method performed well under rotation. The maximum von Mises stress of the implants was not large. For the plate-screw system, the maximum von Mises stress occurred over the region of the fracture and plate-screw joints. The maximum von Mises stress appeared on the rod-screw and screw-bone interfaces for the rod-screw system. The present study showed the biomechanical advantages of internal fixation methods for FPS from a finite element view. Superior stabilization of the anterior pelvic ring and fracture gaps was obtained by internal fixation. Subcutaneous fixation had satisfactory outcomes as well. Sub-rod fixation offered good anti-compression, while the Sub-plate fixation provided favorable anti-rotational capacity.
Biomechanical analysis of posteromedial tibial plateau split fracture fixation.
Zeng, Zhi-Min; Luo, Cong-Feng; Putnis, Sven; Zeng, Bing-Fang
2011-01-01
The purpose of this study was to compare the biomechanical strength of four different fixation methods for a posteromedial tibial plateau split fracture. Twenty-eight tibial plateau fractures were simulated using right-sided synthetic tibiae models. Each fracture model was randomly instrumented with one of the four following constructs, anteroposterior lag-screws, an anteromedial limited contact dynamic compression plate (LC-DCP), a lateral locking plate, or a posterior T-shaped buttress plate. Vertical subsidence of the posteromedial fragment was measured from 500 N to 1500 N during biomechanical testing, the maximum load to failure was also determined. It was found that the posterior T-shaped buttress plate allowed the least subsidence of the posteromedial fragment and produced the highest mean failure load than each of the other three constructs (P=0.00). There was no statistical significant difference between using lag screws or an anteromedial LC-DCP construct for the vertical subsidence at a 1500 N load and the load to failure (P>0.05). This study showed that a posterior-based buttress technique is biomechanically the most stable in-vitro fixation method for posteromedial split tibial plateau fractures, with AP screws and anteromedial-based LC-DCP are not as stable for this type of fracture. Copyright © 2010 Elsevier B.V. All rights reserved.
Wilson, Samuel T; Aylward, Frank O; Ribalet, Francois; Barone, Benedetto; Casey, John R; Connell, Paige E; Eppley, John M; Ferrón, Sara; Fitzsimmons, Jessica N; Hayes, Christopher T; Romano, Anna E; Turk-Kubo, Kendra A; Vislova, Alice; Armbrust, E Virginia; Caron, David A; Church, Matthew J; Zehr, Jonathan P; Karl, David M; DeLong, Edward F
2017-07-31
The temporal dynamics of phytoplankton growth and activity have large impacts on fluxes of matter and energy, yet obtaining in situ metabolic measurements of sufficient resolution for even dominant microorganisms remains a considerable challenge. We performed Lagrangian diel sampling with synoptic measurements of population abundances, dinitrogen (N 2 ) fixation, mortality, productivity, export and transcription in a bloom of Crocosphaera over eight days in the North Pacific Subtropical Gyre (NPSG). Quantitative transcriptomic analyses revealed clear diel oscillations in transcript abundances for 34% of Crocosphaera genes identified, reflecting a systematic progression of gene expression in diverse metabolic pathways. Significant time-lagged correspondence was evident between nifH transcript abundance and maximal N 2 fixation, as well as sepF transcript abundance and cell division, demonstrating the utility of transcriptomics to predict the occurrence and timing of physiological and biogeochemical processes in natural populations. Indirect estimates of carbon fixation by Crocosphaera were equivalent to 11% of net community production, suggesting that under bloom conditions this diazotroph has a considerable impact on the wider carbon cycle. Our cross-scale synthesis of molecular, population and community-wide data underscores the tightly coordinated in situ metabolism of the keystone N 2 -fixing cyanobacterium Crocosphaera, as well as the broader ecosystem-wide implications of its activities.
Pre-clinical evaluation of the mechanical properties of a low-stiffness cement-injectable hip stem.
Eldesouky, Ibrahim; Harrysson, Ola; Marcellin-Little, Denis J; West, Harvey; El-Hofy, Hassan
2017-11-01
In total hip arthroplasty (THA), the femoral stem can be fixed with or without bone cement. Cementless stem fixation is recommended for young and active patients as it eliminates the risk of loss of fixation at the bone-cement and cement-implant interfaces. Cementless fixation, however, suffers from a relatively high early revision rate. In the current research, a novel low-stiffness hip stem was designed, fabricated and tested. The stem design provided the option to inject biodegradable bone cement that could enhance initial stem stability. The stem was made of Ti6Al4V alloy. The proximal portion of the stem was porous, with cubic cells. The stem was fabricated using electron beam melting (EBM) technology and tested in compression and bending. Finite-element analysis was used to evaluate stem performance under a dynamic load representing a stair descending cycle and compare it to the performance of a solid stem with similar geometry. The von Mises stresses and maximum principal strains generated within the bone increased after porous stem insertion compared to solid stem insertion. The low-modulus stem tested in this study has acceptable mechanical properties and generates strain patterns in bone that appear compatible with clinical use.
Posterior fixation including the fractured vertebra for severe unstable thoracolumbar fractures.
Kanna, Rishi M; Shetty, Ajoy Prasad; Rajasekaran, S
2015-02-01
Traditional short-segment fixation of unstable thoracolumbar injuries can be associated with progressive kyphosis and implant failure. Load sharing classification (LSC) recommends supplemental anterior reconstruction for fractures of score 7 or greater. Posterior fixation including the fractured vertebra (PFFV) has biomechanical advantages over conventional short-segment fixation. However, its efficacy in severe thoracolumbar injuries (LSC≥7) has not been studied. To study the clinical, functional, and radiologic results of PFFV for severe, unstable thoracolumbar injuries (LSC≥7) at a minimum of 2 years. A retrospective review of case records. Thirty-two patients with an unstable burst fracture of LSC≥7 treated with PFFV were included. They included clinical outcomes: American Spinal Injury Association grade, visual analog scale (VAS), Oswestry Disability Index (ODI); and radiologic measures: segmental kyphosis angle, vertebral wedge angle, and percentage loss of anterior and posterior vertebral height. Thirty-two patients with LSC≥7 who had undergone PFFV, with a minimum follow-up of 2 years were studied for demographic, injury, and surgical details. Clinical and radiologic outcomes were measured before surgery and at 6, 12, and 24 months postoperatively. The presence of screw breakage, screw pullout, peri-implant loosening, and rod breakage were considered as criteria for implant failure. None of the patients had postoperative implant failure at the final follow-up. The mean preoperative kyphosis angle was 22.9°±7.6°. This improved significantly to 9.2°±6.6° after surgery (p=.000). There was a loss of mean 2.4° (mean kyphosis angle of 11.6°±6.3°) at the final follow-up. The mean preoperative wedge angle was 23.0°±8.1°. This was corrected to 9.7°±6.2° (p=.000). There was a loss of kyphosis (mean 1.2°) in the follow-up period. The mean anterior and posterior vertebral height also showed significant improvements postoperatively, which were maintained at the final follow-up. The mean ODI and VAS scores at the end of 2 years were 17.5% and 1.6, respectively. Reduction of unstable thoracolumbar injuries even with LSC≥7 can be achieved and maintained with the use of short-segment pedicle screw fixation including the fractured vertebra, avoiding the need for anterior reconstruction. In the current era of evolving concepts of fracture fixation, the relevance of LSC in the management of unstable burst fractures is questionable. Copyright © 2015 Elsevier Inc. All rights reserved.
Doherty, Patrick; Welch, Arthur; Tharpe, Jason; Moore, Camille; Ferry, Chris
2017-05-30
Studies have shown that a significant learning curve may be associated with adopting minimally invasive transforaminal lumbar interbody fusion (MIS TLIF) with bilateral pedicle screw fixation (BPSF). Accordingly, several hybrid TLIF techniques have been proposed as surrogates to the accepted BPSF technique, asserting that less/fewer fixation(s) or less disruptive fixation may decrease the learning curve while still maintaining the minimally disruptive benefits. TLIF with interspinous process fixation (ISPF) is one such surrogate procedure. However, despite perceived ease of adaptability given the favorable proximity of the spinous processes, no evidence exists demonstrating whether or not the technique may possess its own inherent learning curve. The purpose of this study was to determine whether an intraoperative learning curve for one- and two-level TLIF + ISPF may exist for a single lead surgeon. Seventy-four consecutive patients who received one- or two-Level TLIF with rigid ISPF by a single lead surgeon were retrospectively reviewed. It was the first TLIF + ISPF case series for the lead surgeon. Intraoperative blood loss (EBL), hospitalization length-of-stay (LOS), fluoroscopy time, and postoperative complications were collected. EBL, LOS, and fluoroscopy time were modeled as a function of case number using multiple linear regression methods. A change point was included in each model to allow the trajectory of the outcomes to change during the duration of the case series. These change points were determined using profile likelihood methods. Models were fit using the maximum likelihood estimates for the change points. Age, sex, body mass index (BMI), and the number of treated levels were included as covariates. EBL, LOS, and fluoroscopy time did not significantly differ by age, sex, or BMI (p ≥ 0.12). Only EBL differed significantly by the number of levels (p = 0.026). The case number was not a significant predictor of EBL, LOS, or fluoroscopy time (p ≥ 0.21). At the time of data collection (mean time from surgery: 13.3 months), six patients had undergone revision due to interbody migration. No ISPF device complications were observed. Study outcomes support the ideal that TLIF + ISPF can be a readily adopted procedure without a significant intraoperative learning curve. However, the authors emphasize that further assessment of long-term healing outcomes is essential in fully characterizing both the efficacy and the indication learning curve for the TLIF + ISPF technique.
The effect of hubs and shortcuts on fixation time in evolutionary graphs
NASA Astrophysics Data System (ADS)
Askari, Marziyeh; Moradi Miraghaei, Zeinab; Aghababaei Samani, Keivan
2017-07-01
How can a new species (like a gene, an idea, or a strategy) take over the whole of a population? This process, which is called fixation, is considerably affected by the structure of the population. There are two key quantities to quantify the fixation process, namely fixation probability and fixation time. Fixation probability has been vastly studied in recent years, but fixation time has not been completely explored, yet. This is because the discovery of a relationship between fixation time and network structure is quite challenging. In this paper we investigate this relationship for a number of well-known complex networks. We show that the existence of a few high-degree nodes (hubs) in the network results in a longer fixation time, while the existence of a few short-cuts decreases the fixation time. Furthermore we investigate the effect of network parameters, such as connection probability, on fixation time. We show that by increasing the density of edges, fixation time decreases for all types of studied networks. Finally, we survey the effect of rewiring probability in a Watts-Strogatz network on fixation time.
Dynamic ultraslow optical-matter wave analog of an event horizon.
Zhu, C J; Deng, L; Hagley, E W; Ge, Mo-Lin
2014-08-29
We investigate theoretically the effects of a dynamically increasing medium index on optical-wave propagation in a rubidium condensate. A long pulsed pump laser coupling a D2 line transition produces a rapidly growing internally generated field. This results in a significant optical self-focusing effect and creates a dynamically growing medium index anomaly that propagates ultraslowly with the internally generated field. When a fast probe pulse injected after a delay catches up with the dynamically increasing index anomaly, it is forced to slow down and is prohibited from crossing the anomaly, thereby realizing an ultraslow optical-matter wave analog of a dynamic white-hole event horizon.
Chung, Kyu Sung; Choi, Choong Hyeok; Bae, Tae Soo; Ha, Jeong Ku; Jun, Dal Jae; Wang, Joon Ho; Kim, Jin Goo
2018-04-01
To compare tibiofemoral contact mechanics after fixation for medial meniscus posterior root radial tears (MMPRTs). Seven fresh knees from mature pigs were used. Each knee was tested under 5 conditions: normal knee, MMPRT, pullout fixation with simple sutures, fixation with modified Mason-Allen sutures, and all-inside fixation using Fastfix 360. The peak contact pressure and contact surface area were evaluated using a capacitive sensor positioned between the meniscus and tibial plateau, under a 1,000-N compression force, at different flexion angles (0°, 30°, 60°, and 90°). The peak contact pressure was significantly higher in MMPRTs than in normal knees (P = .018). Although the peak contact pressure decreased significantly after fixation at all flexion angles (P = .031), it never recovered to the values noted in the normal meniscus. No difference was observed among fixation groups (P = .054). The contact surface area was significantly lower in MMPRTs than in the normal meniscus (P = .018) and increased significantly after fixation at all flexion angles (P = .018) but did not recover to within normal limits. For all flexion angles except 60°, the contact surface area was significantly higher for fixation with Mason-Allen sutures than for fixation with simple sutures or all-inside fixation (P = .027). At 90° of flexion, the contact surface area was significantly better for fixation with simple sutures than for all-inside fixation (P = .031). The peak contact pressure and contact surface area improved significantly after fixation, regardless of the fixation method, but did not recover to the levels noted in the normal meniscus after any type of fixation. Among the fixation methods evaluated in this time 0 study, fixation using modified Mason-Allen sutures provided a superior contact surface area compared with that noted after fixation using simple sutures or all-inside fixation, except at 60° of flexion. However, this study had insufficient power to accurately detect the differences between the outcomes of various fixation methods. Our results in a porcine model suggest that fixation can restore tibiofemoral contact mechanics in MMPRT and that fixation with a locking mechanism leads to superior biomechanical properties. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Gary, Joshua L; Lefaivre, Kelly A; Gerold, Frank; Hay, Michael T; Reinert, Charles M; Starr, Adam J
2011-10-01
Our purpose was to examine survivorship of the native hip joint in patients ages 60 and over who underwent percutaneous reduction and fixation of acetabular fractures. A retrospective review at a University Level I Trauma Center was performed. Our institutional trauma database was reviewed. Patients aged 60 or older treated with percutaneous reduction and fixation of acetabular fractures between 1994 and 2007 were selected. 79 consecutive patients with 80 fractures were identified. Rate of conversion to total hip arthroplasty were used to construct a Kaplan-Meier curve showing survivorship of the native hip joint after treatment. 75 fractures had adequate clinical follow-up with a mean of 3.9 years (range 0.5-11.9 years). Average blood loss was 69 cc and there were no postoperative infections. 19/75 (25%) were converted to total hip arthroplasty at a mean time of 1.4 years after the index procedure. Survivorship analysis demonstrated a cumulative survival of 65% at 11.9 years of follow-up. There were no conversions to arthroplasty beyond 4.7 years postoperatively. There were no statistically significant associations between conversion to arthroplasty and age, sex, closed vs. limited open reduction, and simple vs. complex fracture pattern. Percutaneous fixation is a viable treatment option for patients age 60 or greater with acetabular fractures. Rates of conversion to total hip arthroplasty are comparable to open treatment methods and if conversion is required, soft tissues are preserved for future surgery. Copyright © 2010 Elsevier Ltd. All rights reserved.
Expression of TGF-β in Fractures Fixed by Nitinol Swan-like Memory Compressive Connectors
NASA Astrophysics Data System (ADS)
Li, M.; Zhang, C. C.; Xu, S. G.; Fu, Q. G.
2011-07-01
In this article, the effect of internal fixation of a Nitinol swan-like memory compressive connector (SMC) on the temporal expression of transforming growth factor-β (TGF-β) at fracture sites is evaluated. Specimens were collected from 35 New Zealand rabbits modeled for bilateral humeral fracture fixed with either SMC or stainless dynamic compression plate (DCP). Five rabbits each were killed at day 1, 3, 7, 14, 21, 28, and 56. The local positive staining potency, positive area ratio, and positive index of TGF-β were measured using an immunohistochemistry approach (EnVision) in combination with a computerized image analysis system. TGF-β staining was seen in mesenchymal cells, osteoblasts, chondrocytes, and in the extracellular matrix of fractures fixed in both the SMC and the DCP samples without a significant difference in staining at both the early stages (days 1 and 3) and day 56. A higher TGF-β content was observed in the fractures fixed with SMC when compared to that of DCP from day 7 to 28. As a conclusion, TGF-β is highly expressed in fractures fixed with SMC during chondrogenesis stage and entochondrostosis stage. Finally, the mechanism of how SMC promoting synthesis and secretion of TGF-β in the process of fracture healing has been discussed.
Bilateral double level tibial lengthening in dwarfism.
Burghardt, Rolf D; Yoshino, Koichi; Kashiwagi, Naoya; Yoshino, Shigeo; Bhave, Anil; Paley, Dror; Herzenberg, John E
2015-12-01
Outcome assessment after double level tibial lengthening in patients with dwarfism. Fourteen patients with dwarfism were analyzed after bilateral simultaneous double level tibial lengthening. Average age was 15.1 years. Average lengthening was 13.5 cm. The two levels were lengthened by an average of 7.5 cm proximally and 6.0 cm distally. Concomitant deformities were also addressed during lengthening. External fixation treatment time averaged 8.8 months. Healing index averaged 0.7 months/cm. Bilateral tibial lengthening for dwarfism is difficult, but the results are usually quite gratifying.
Eighth international congress on nitrogen fixation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1990-01-01
This volume contains the proceedings of the Eighth International Congress on Nitrogen Fixation held May 20--26, 1990 in Knoxville, Tennessee. The volume contains abstracts of individual presentations. Sessions were entitled Recent Advances in the Chemistry of Nitrogen Fixation, Plant-microbe Interactions, Limiting Factors of Nitrogen Fixation, Nitrogen Fixation and the Environment, Bacterial Systems, Nitrogen Fixation in Agriculture and Industry, Plant Function, and Nitrogen Fixation and Evolution.
Eighth international congress on nitrogen fixation. Final program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1990-12-31
This volume contains the proceedings of the Eighth International Congress on Nitrogen Fixation held May 20--26, 1990 in Knoxville, Tennessee. The volume contains abstracts of individual presentations. Sessions were entitled Recent Advances in the Chemistry of Nitrogen Fixation, Plant-microbe Interactions, Limiting Factors of Nitrogen Fixation, Nitrogen Fixation and the Environment, Bacterial Systems, Nitrogen Fixation in Agriculture and Industry, Plant Function, and Nitrogen Fixation and Evolution.
NASA Astrophysics Data System (ADS)
Bonnet, S.; Berthelot, H.; Turk-Kubo, K.; Fawcett, S.; Rahav, E.; l'Helguen, S.; Berman-Frank, I.
2015-12-01
N2 fixation rates were measured daily in large (~ 50 m3) mesocosms deployed in the tropical South West Pacific coastal ocean (New Caledonia) to investigate the spatial and temporal dynamics of diazotrophy and the fate of diazotroph-derived nitrogen (DDN) in a low nutrient, low chlorophyll ecosystem. The mesocosms were intentionally fertilized with ~ 0.8 μM dissolved inorganic phosphorus (DIP) to stimulate diazotrophy. Bulk N2 fixation rates were replicable between the three mesocosms, averaged 18.5 ± 1.1 nmol N L-1 d-1 over the 23 days, and increased by a factor of two during the second half of the experiment (days 15 to 23) to reach 27.3 ± 1.0 nmol N L-1 d-1. These rates are higher than the upper range reported for the global ocean, indicating that the waters surrounding New Caledonia are particularly favourable for N2 fixation. During the 23 days of the experiment, N2 fixation rates were positively correlated with seawater temperature, primary production, bacterial production, standing stocks of particulate organic carbon, nitrogen and phosphorus, and alkaline phosphatase activity, and negatively correlated with DIP concentrations, DIP turnover time, nitrate, and dissolved organic nitrogen and phosphorus concentrations. The fate of DDN was investigated during the bloom of the unicellular diazotroph, UCYN-C, that occurred during the second half of the experiment. Quantification of diazotrophs in the sediment traps indicates that ~ 10 % of UCYN-C from the water column were exported daily to the traps, representing as much as 22.4 ± 5.5 % of the total POC exported at the height of the UCYN-C bloom. This export was mainly due to the aggregation of small (5.7 ± 0.8 μm) UCYN-C cells into large (100-500 μm) aggregates. During the same time period, a DDN transfer experiment based on high-resolution nanometer scale secondary ion mass spectrometry (nanoSIMS) coupled with 15N2 isotopic labelling revealed that 16 ± 6 % of the DDN was released to the dissolved pool and 21 ± 4 % was transferred to non-diazotrophic plankton, mainly picoplankton (18 ± 4 %) followed by diatoms (3 ± 2 %) within 24 h of incubation. This is consistent with the observed dramatic increase in picoplankton and diatom abundances, primary production, bacterial production and standing stocks of particulate organic carbon, nitrogen and phosphorus during the second half of the experiment in the mesocosms. These results offer insights into the fate of DDN during a bloom of UCYN-C in low nutrient, low chlorophyll ecosystems.
Visual Contrast Sensitivity in Early-Stage Parkinson's Disease.
Ming, Wendy; Palidis, Dimitrios J; Spering, Miriam; McKeown, Martin J
2016-10-01
Visual impairments are frequent in Parkinson's disease (PD) and impact normal functioning in daily activities. Visual contrast sensitivity is a powerful nonmotor sign for discriminating PD patients from controls. However, it is usually assessed with static visual stimuli. Here we examined the interaction between perception and eye movements in static and dynamic contrast sensitivity tasks in a cohort of mildly impaired, early-stage PD patients. Patients (n = 13) and healthy age-matched controls (n = 12) viewed stimuli of various spatial frequencies (0-8 cyc/deg) and speeds (0°/s, 10°/s, 30°/s) on a computer monitor. Detection thresholds were determined by asking participants to adjust luminance contrast until they could just barely see the stimulus. Eye position was recorded with a video-based eye tracker. Patients' static contrast sensitivity was impaired in the intermediate spatial-frequency range and this impairment correlated with fixational instability. However, dynamic contrast sensitivity and patients' smooth pursuit were relatively normal. An independent component analysis revealed contrast sensitivity profiles differentiating patients and controls. Our study simultaneously assesses perceptual contrast sensitivity and eye movements in PD, revealing a possible link between fixational instability and perceptual deficits. Spatiotemporal contrast sensitivity profiles may represent an easily measurable metric as a component of a broader combined biometric for nonmotor features observed in PD.
He, Wanzhong; Kivork, Christine; Machinani, Suman; Morphew, Mary K.; Gail, Anna M.; Tesar, Devin B.; Tiangco, Noreen E.; McIntosh, J. Richard; Bjorkman, Pamela J.
2007-01-01
We have developed methods to locate individual ligands that can be used for electron microscopy studies of dynamic events during endocytosis and subsequent intracellular trafficking. The methods are based on enlargement of 1.4 nm Nanogold attached to an endocytosed ligand. Nanogold, a small label that does not induce misdirection of ligand-receptor complexes, is ideal for labeling ligands endocytosed by live cells, but is too small to be routinely located in cells by electron microscopy. Traditional pre-embedding enhancement protocols to enlarge Nanogold are not compatible with high pressure freezing/freeze substitution fixation (HPF/FSF), the most accurate method to preserve ultrastructure and dynamic events during trafficking. We have developed an improved enhancement procedure for chemically-fixed samples that reduced autonucleation, and a new pre-embedding gold-enlarging technique for HPF/FSF samples that preserved contrast and ultrastructure and can be used for high-resolution tomography. We evaluated our methods using labeled Fc as a ligand for the neonatal Fc receptor. Attachment of Nanogold to Fc did not interfere with receptor binding or uptake, and gold-labeled Fc could be specifically enlarged to allow identification in 2D projections and in tomograms. These methods should be broadly applicable to many endocytosis and transcytosis studies. PMID:17723309
Major role of microbes in carbon fluxes during Austral winter in the Southern Drake Passage.
Manganelli, Maura; Malfatti, Francesca; Samo, Ty J; Mitchell, B Greg; Wang, Haili; Azam, Farooq
2009-09-14
Carbon cycling in Southern Ocean is a major issue in climate change, hence the need to understand the role of biota in the regulation of carbon fixation and cycling. Southern Ocean is a heterogeneous system, characterized by a strong seasonality, due to long dark winter. Yet, currently little is known about biogeochemical dynamics during this season, particularly in the deeper part of the ocean. We studied bacterial communities and processes in summer and winter cruises in the southern Drake Passage. Here we show that in winter, when the primary production is greatly reduced, Bacteria and Archaea become the major producers of biogenic particles, at the expense of dissolved organic carbon drawdown. Heterotrophic production and chemoautotrophic CO(2) fixation rates were substantial, also in deep water, and bacterial populations were controlled by protists and viruses. A dynamic food web is also consistent with the observed temporal and spatial variations in archaeal and bacterial communities that might exploit various niches. Thus, Southern Ocean microbial loop may substantially maintain a wintertime food web and system respiration at the expense of summer produced DOC as well as regenerate nutrients and iron. Our findings have important implications for Southern Ocean ecosystem functioning and carbon cycle and its manipulation by iron enrichment to achieve net sequestration of atmospheric CO(2).
Kim, Kyeong Hwan; Kim, Wan Soo
2015-09-01
To compare the efficacy and safety of iris fixation with scleral fixation in surgical repositioning of dislocated intraocular lenses (IOLs). Retrospective, consecutive, comparative interventional case series. setting: Referral hospital. Seventy-eight consecutive patients who underwent surgical repositioning of dislocated intraocular lenses using suturing to the sclera or iris. Forty-four eyes of 44 patients underwent scleral fixation and 35 eyes of 34 patients underwent iris fixation of dislocated intraocular lenses. Visual acuity, refractive stability, operation time, and perioperative complications, including recurrence of IOL dislocation. Corrected distance visual acuity (CDVA) improved significantly 1 month postoperatively in both groups (P < .01 each), and remained stable for 12 months. One week postoperatively, however, CDVA improved significantly in the scleral fixation (P = .040) but not in the iris fixation (P = .058) group. The amount of refractive error significantly diminished 1 day after surgery (P = .028 in the scleral fixation and P = .046 in the iris fixation group). For the astigmatic components, Jackson crossed cylinders equivalent to conventional cylinders of positive power at axes of 0 degrees (J0) and 45 degrees (J45), J45 differed significantly in the scleral fixation and iris fixation groups (P = .009), whereas J0 was similar (P > .05). Operation time was significantly shorter (P = .0007), while immediate postoperative inflammation was significantly more severe (P = .001), in the iris fixation than in the scleral fixation group. Recurrence rates were similar (P > .05), but the mean time to recurrence was significantly shorter in the iris fixation than in the scleral fixation group (P = .031). Iris fixation and scleral fixation techniques had similar efficacy in the repositioning of dislocated intraocular lenses. Although operation time was shorter for iris fixation, it had several disadvantages, including induced astigmatism, immediate postoperative inflammation, earlier recurrence, and less stable refraction. Copyright © 2015 Elsevier Inc. All rights reserved.
Lawley, Richard J; Klein, Samuel E; Chudik, Steven C
2017-03-01
To evaluate the biomechanical performance of tibial cross-pin (TCP) fixation relative to femoral cross-pin (FCP), femoral interference screw (FIS), and tibial interference screw (TIS) fixation. We randomized 40 porcine specimens (20 tibias and 20 femurs) to TIS fixation (group 1, n = 10), FIS fixation (group 2, n = 10), TCP fixation (group 3, n = 10), or FCP fixation (group 4, n = 10) and performed biomechanical testing to compare ultimate load, stiffness, yield load, cyclic displacement, and load at 5-mm displacement. We performed cross-pin fixation of the looped end and interference screw fixation of the free ends of 9-mm-diameter bovine extensor digitorum communis tendon grafts. Graft fixation constructs were cyclically loaded and then loaded to failure in line with the tunnels. Regarding yield load, FIS was superior to TIS (704 ± 125 N vs 504 ± 118 N, P = .002), TCP was superior to TIS (1,449 ± 265 N vs 504 ± 118 N, P < .001), and TCP was superior to FCP (1,449 ± 265 N vs 792 ± 397 N, P < .001). Cyclic displacement for FCP was superior to TCP. Cyclic displacement for TIS versus FIS showed no statistically significant difference (2.5 ± 1.0 mm vs 2.2 ± 0.6 mm, P = .298). Interference screw fixation consistently failed by graft slippage, whereas TCP fixation failed by tibial bone failure. FCP fixation failed by either femoral bone failure or failure elsewhere in the testing apparatus. Regarding yield load, TCP fixation performed biomechanically superior to the clinically proven FCP at time zero. Because TIS fixation shows the lowest yield strength, it represents the weak link, and combined TCP-FIS fixation theoretically would be biomechanically superior relative to combined FCP-TIS fixation with regard to yield load. Cyclic displacement showed a small difference in favor of FCP over TCP fixation and no difference between TIS and FIS. Time-zero biomechanics of TCP fixation paired with FIS fixation show that this method of fixation can be considered a potential alternative to current practice and may pose clinical benefits in different clinical scenarios of anterior cruciate ligament reconstruction. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Structural drift: the population dynamics of sequential learning.
Crutchfield, James P; Whalen, Sean
2012-01-01
We introduce a theory of sequential causal inference in which learners in a chain estimate a structural model from their upstream "teacher" and then pass samples from the model to their downstream "student". It extends the population dynamics of genetic drift, recasting Kimura's selectively neutral theory as a special case of a generalized drift process using structured populations with memory. We examine the diffusion and fixation properties of several drift processes and propose applications to learning, inference, and evolution. We also demonstrate how the organization of drift process space controls fidelity, facilitates innovations, and leads to information loss in sequential learning with and without memory.
Zhao, Huan-Li; Wang, Gui-Bin; Jia, Yue-Qing; Zhu, Shi-Cai; Zhang, Feng-Fang; Liu, Hong-Mei
2015-01-01
Background To compare risk of carpal tunnel syndrome (CTS) in distal radius fracture (DRF) patients after 7 treatments using bridging external fixation (BrEF), non-bridging external fixation (non-BrEF), plaster fixation, K-wire fixation, dorsal plating fixation, volar plating fixation, and dorsal and volar plating by performing a network meta-analysis. Material/Methods An exhaustive search of electronic databases identified randomized controlled trails (RCTs) closely related to our study topic. The published articles were screened, based on predefined inclusion and exclusion criteria, to select high-quality studies for the present network meta-analysis. Data extracted from the selected studies were analyzed using STATA version 12.0 software. Results The literature search and selection process identified 12 eligible RCTs that contained a total of 1370 DRF patients (394 patients with BrEF, 377 patients with non-BrEF, 89 patients with K-wire fixation, 192 patients with plaster fixation, 42 patients with dorsal plating fixation, 152 patients with volar plating fixation, and 124 patients with dorsal and volar plating fixation). Our network meta-analysis results demonstrated no significant differences in CTS risk among the 7 treatments (P>0.05). The value of surface under the cumulative ranking curve (SUCRA), however, suggested that dorsal plating fixation is the optimal treatment, with the lowest risk of CTS in DRF patients (dorsal plating fixation: 89.2%; dorsal and volar plating: 57.8%; plaster fixation: 50.9%; non-BrEF: 50.6%; volar plating fixation: 39.6%; BrEF: 38.4%; K-wire fixation: 23.6%). Conclusions Our network meta-analysis provides evidence that dorsal plating fixation significantly decreases the risk of CTS and could be the method of choice in DRF patients. PMID:26391617
Miller, Mark Carl; Redman, Christopher N; Mistovich, R Justin; Muriuki, Muturi; Sangimino, Mark J
2017-09-01
Pin fixation of Salter-II proximal humeral fractures in adolescents approaching skeletal maturity has potential complications that can be avoided with single-screw fixation. However, the strength of screw fixation relative to parallel and diverging pin fixation is unknown. To compare the biomechanical fixation strength between these fixation modalities, we used synthetic composite humeri, and then compared these results in composite bone with cadaveric humeri specimens. Parallel pinning, divergent pinning, and single-screw fixation repairs were performed on synthetic composite humeri with simulated fractures. Six specimens of each type were tested in axial loading and other 6 were tested in torsion. Five pair of cadaveric humeri were tested with diverging pins and single screws for comparison. Single-screw fixation was statistically stronger than pin fixation in axial and torsional loading in both composite and actual bone. There was no statistical difference between composite and cadaveric bone specimens. Single-screw fixation can offer greater stability to adolescent Salter-II fractures than traditional pinning. Single-screw fixation should be considered as a viable alternative to percutaneous pin fixation in transitional patients with little expected remaining growth.
2010-01-01
Although there is a clear trend toward internal fixation for ankle arthrodesis, there is general consensus that external fixation is required for cases of posttraumatic infection. We retrospectively evaluated the technique and clinical long term results of external fixation in a triangular frame for cases of posttraumatic infection of the ankle. From 1993 to 2006 a consecutive series of 155 patients with an infection of the ankle was included in our study. 133 cases of the advanced "Gächter" stage III and IV were treated with arthrodesis. We treated the patients with a two step treatment plan. After radical debridement and sequestrectomy the malleoli and the joint surfaces were resected. An AO fixator was applied with two Steinmann-nails inserted in the tibia and in the calcaneus and the gap was temporary filled with gentamicin beads as the first step. In the second step we performed an autologous bone graft after a period of four weeks. The case notes were evaluated regarding trauma history, medical complaints, further injuries and illnesses, walking and pain status and occupational issues. Mean age at the index procedure was 49.7 years (18-82), 104 patients were male (67,1%). Follow up examination after mean 4.5 years included a standardised questionnaire and a clinical examination including the criteria of the AO-FAS-Score and radiographs. 92,7% of the cases lead to a stable arthrodesis. In 5 patients the arthrodesis was found partly-stable. In six patients (4,5%) the infection was not controllable during the treatment process. These patients had to be treated with a below knee amputation. The mean AOFAS score at follow up was 63,7 (53-92). Overall there is a high degree of remaining disability. The complication rate and the reduced patient comfort reserve this method mainly for infection. Joint salvage is possible in the majority of cases with an earlier stage I and II infection. PMID:20452884
Kienast, Benjamin; Kiene, J; Gille, J; Thietje, R; Gerlach, U; Schulz, A P
2010-02-26
Although there is a clear trend toward internal fixation for ankle arthrodesis, there is general consensus that external fixation is required for cases of posttraumatic infection. We retrospectively evaluated the technique and clinical long term results of external fixation in a triangular frame for cases of posttraumatic infection of the ankle. From 1993 to 2006 a consecutive series of 155 patients with an infection of the ankle was included in our study. 133 cases of the advanced "Gächter" stage III and IV were treated with arthrodesis. We treated the patients with a two step treatment plan. After radical debridement and sequestrectomy the malleoli and the joint surfaces were resected. An AO fixator was applied with two Steinmann-nails inserted in the tibia and in the calcaneus and the gap was temporary filled with gentamicin beads as the first step. In the second step we performed an autologous bone graft after a period of four weeks. The case notes were evaluated regarding trauma history, medical complaints, further injuries and illnesses, walking and pain status and occupational issues. Mean age at the index procedure was 49.7 years (18-82), 104 patients were male (67.1%). Follow up examination after mean 4.5 years included a standardised questionnaire and a clinical examination including the criteria of the AOFAS-Score and radiographs. 92.7% of the cases lead to a stable arthrodesis. In 5 patients the arthrodesis was found partly-stable. In six patients (4,5%) the infection was not controllable during the treatment process. These patients had to be treated with a below knee amputation. The mean AOFAS score at follow up was 63.7 (53-92). Overall there is a high degree of remaining disability. The complication rate and the reduced patient comfort reserve this method mainly for infection. Joint salvage is possible in the majority of cases with an earlier stage I and II infection.
Clinical outcomes of a polyaxial interspinous fusion system.
Sclafani, Joseph A; Liang, Kevin; Ohnmeiss, Donna D; Gordon, Charles
2014-01-01
Early interspinous process fixation constructs utilize rigid fixation plates with immobile spikes which increase the difficulty of device implantation when anatomic variations are encountered. Second generation systems have been designed with polyaxial properties with the goal of accommodating natural osseous anatomic variations to achieve optimal implant placement and fixation integrity. The purpose of this study was to evaluate clinical outcomes in patients treated with this device to supplement the biomechanical data from previous studies. A retrospective, non-randomized, single-center chart review at or beyond the one year postoperative time point was conducted to collect preoperative and perioperative data on patients treated with a polyaxial intraspinous fixation system. A postoperative numerical pain rating scale and modified MacNab classification score were obtained from each patient in the cohort via phone survey. A total of 53 patients were included in the study. Median hospital stay was 2 days (range 1-7 days). There were no reported perioperative blood transfusions or cases of radiographic fracture/migration of the device at the 6 week post-operative time point. There was a significant improvement in pain index score in the overall patient study group and a satisfactory (excellent or good) MacNab result was obtained in 48% of all patients. Patients with preoperative pain scores greater than 8/10 reported more pain improvement than patients with preoperative pain scores less than 5 (0 points, p = 0.96, n = 8). Patients with a BMI less than 30 had significantly better MacNab outcome classifications than patients with a BMI greater than 30. The polyaxial interspinous fusion system produces significant clinical improvement when employed to treat patients with stenosis, herniated disc, or low grade spondylolisthesis. This device can be implanted with a low complication rate and short postoperative hospital admission time. Patients with high pre-operative pain score and BMI under 30 can be predictors of better clinical outcome and should be considered prior to implantation.
Shin, Sung Joon; Lee, Ji-Ho; Lee, Jae Hyup
2017-07-01
A prospective, within-patient, left-right comparative study. To evaluate the efficacy of hydroxyapatite (HA) stick augmentation method by comparing the insertional torque of the pedicle screw in osteoporotic and nonosteoporotic patients. Unsatisfactory clinical outcomes after spine surgery in osteoporotic patients are related to pedicle screw loosening or pull-outs. HA, as a bone graft extender, has a possibility to enhance the fixation strength at the bone-screw interface. From November 2009 to December 2010, among patients who required bilateral pedicle screw fixation for lumbar spine surgery, 22 patients were enrolled, who recieved unilateral HA stick augmentation and completed intraoperative insertional torque measurement of each pedicle screws. On the basis of preoperative evaluation of bone mineral density, patients with osteoporosis had 2 HA sticks inserted unilaterally, and 1 stick for patients without osteoporosis. Pedicle screw loosening and pull-outs were assessed using 12-month postoperative CT scans and follow-up radiographs. Clinical evaluation was done preoperatively and at 1 year postoperatively, based on Visual Analog Scale score, Oswestry Disability Index, and Short Form-36 Health Survey. Regardless of bone mineral density, the average torque value of all pedicle screws with HA stick insertion (HA stick inserted group) was significantly higher than that of all pedicle screws without HA insertion (control group) (P<0.0001). Same results were seen in the HA stick inserted subgroups and the control subgroups within both of the osteoporosis group (P=0.009) and the nonosteoporosis group (P=0.0004). There was no statistically significant difference of the rate of pedicle screw loosening in between the HA stick inserted group and the control group. Clinical evaluation also showed no statistically significant difference in between patients with loosening and those without. The enhancement of initial pedicle screw fixation strength in osteoporotic patients can be achieved by HA stick augmentation.
Comparing solar energy alternatives
NASA Astrophysics Data System (ADS)
White, J. R.
1984-03-01
This paper outlines a computational procedure for comparing the merits of alternative processes to convert solar radiation to heat, electrical power, or chemical energy. The procedure uses the ratio of equipment investment to useful work as an index. Comparisons with conversion counterparts based on conventional fuels are also facilitated by examining this index. The procedure is illustrated by comparisons of (1) photovoltaic converters of differing efficiencies; (2) photovoltaic converters with and without focusing concentrators; (3) photovoltaic conversion plus electrolysis vs photocatalysis for the production of hydrogen; (4) photovoltaic conversion plus plasma arcs vs photocatalysis for nitrogen fixation. Estimates for conventionally-fuelled processes are included for comparison. The reasons why solar-based concepts fare poorly in such comparisons are traced to the low energy density of solar radiation and its low stream time factor resulting from the limited number of daylight hours available and clouds obscuring the sun.
Kopylov, Philippe; Geijer, Mats; Tägil, Magnus
2009-01-01
Background and purpose In unstable distal radial fractures that are impossible to reduce or to maintain in reduced position, the treatment of choice is operation. The type of operation and the choice of implant, however, is a matter of discussion. Our aim was to investigate whether open reduction and internal fixation would produce a better result than traditional external fixation. Methods 50 patients with an unstable or comminute distal radius fracture were randomized to either closed reduction and bridging external fixation, or open reduction and internal fixation using the TriMed system. The primary outcome parameter was grip strength, but the patients were followed for 1 year with objective clinical assessment, subjective outcome using DASH, and radiographic examination. Results At 1 year postoperatively, grip strength was 90% (SD 16) of the uninjured side in the internal fixation group and 78% (17) in the external fixation group. Pronation/supination was 150° (15) in the internal fixation group and 136° (20) in the external fixation group at 1 year. There were no differences in DASH scores or in radiographic parameters. 5 patients in the external fixation group were reoperated due to malunion, as compared to 1 in the internal fixation group. 7 other cases were classified as radiographic malunion: 5 in the external fixation group and 2 in the internal fixation group. Interpretation Internal fixation gave better grip strength and a better range of motion at 1 year, and tended to have less malunions than external fixation. No difference could be found regarding subjective outcome. PMID:19857180
[Comparison of external fixation with or without limited internal fixation for open knee fractures].
Li, K N; Lan, H; He, Z Y; Wang, X J; Yuan, J; Zhao, P; Mu, J S
2018-03-01
Objective: To explore the characteristics and methods of different fixation methods and prevention of open knee joint fracture. Methods: The data of 86 cases of open knee joint fracture admitted from January 2002 to December 2015 in Department of Orthopaedics, Affiliated Hospital of Chengdu University were analyzed retrospectively.There were 65 males and 21 females aged of 38.6 years. There were 38 cases treated with trans articular external fixation alone, 48 cases were in the trans articular external fixation plus auxiliary limited internal fixation group. All the patients were treated according to the same three stages except for different fixation methods. Observation of external fixation and fracture fixation, fracture healing, wound healing and treatment, treatment and related factors of infection control and knee function recovery. χ(2) test was used to analyze data. Results: Eleven patients had primary wound healing, accounting for 12.8%. Seventy-five patients had two wounds healed, accounting for 87.2%. Only 38 cases of trans articular external fixator group had 31 cases of articular surface reduction, accounting for 81.6%; Five cases of trans articular external fixator assisted limited internal fixation group had 5 cases of poor reduction, accounting for 10.4%; There was significant difference between the two groups (χ(2)=44.132, P <0.05). Take a single cross joint external fixation group, a total of 23 cases of patients with infection, accounted for 60.5% of external fixation group; trans articular external fixation assisted limited internal fixation group there were 30 cases of patients with infection, accounting for the assistance of external fixator and limited internal fixation group 62.5%; There was significant difference between the two groups(χ(2)=0.035, P >0.05). Five cases of fracture nonunion cases of serious infection, patients voluntarily underwent amputation. The Lysholm Knee Scale: In the external fixation group, 23 cases were less than 50 points, accounting for 60.5%, 15 cases were more than 50 points, accounting for 39.5%, external fixation and limited internal fixation group 20 cases were less than 50 points, accounting for 41.7%, 28 cases were more than 50 points, accounting for 58.3%; There was significant difference between the two groups(χ(2)=1.279, P >0.05). Conclusions: Prevention and control of infection is a central link in the treatment of open fracture of the knee. Trans articular external fixator plus limited internal fixation is an important measure to treat open fracture of the knee-joint.
Diesing, Daniela; Franke, Joerg; Tschoeke, Sven Kevin; Schultheiß, Rolf; Scheufler, Kai Michael
2018-05-31
Persistent sacroiliac joint syndrome (PSIJS) may complicate adult spinal deformity surgery (ASDS). This study assesses the relationship between clinical/morphometric parameters and PSIJS following ASDS including pelvic fixation and the therapeutic efficacy of secondary iliosacral fusion (ISF). Perioperative health-related quality of life (HRQOL) outcomes (Oswestry Disability Index, Short Form 12-item health survey, version 2 scores) at 6, 12, and 24 months, and radiographic studies were analyzed retrospectively in a cohort of 71 consecutive patients undergoing ASDS. PSIJS was confirmed in nine individuals (12.7%) by placebo-controlled dual sacroiliac joint (SIJ) blocks. The relationships between global and regional spinopelvic morphometry, PSIJS, and HRQOL outcomes were assessed by logistic regression and receiver operating characteristic curve (ROC) analysis. PSIJS, independently causing significantly reduced improvement in HRQOL scores ( p < 0.001) 6 months postoperatively, warranted secondary ISF in nine patients (12.7%) within 12 months of index surgery, without evidence of progressive SIJ arthrosis, pseudarthrosis, or hardware issues. Eight of nine patients undergoing secondary ISF reported≥ 70% pain reduction at 24 months. Logistic regression/ROC analysis revealed a close association between PSIJS and nonharmonious postoperative L4-S1 fractional lordosis ( p < 0.0001), pelvic incidence angle > 53 degrees, hip arthrosis, and preexistent advanced SIJ arthrosis ( p < 0.01). PSIJS may negatively impact the clinical outcome of ASDS. Recurrent preoperative SIJ syndrome requiring interventional treatment, preexisting hip and SIJ arthrosis, insufficient restoration of L4-S1 fractional lordosis, and high pelvic incidence predispose to PSIJS. PSIJS may potentially be avoided by restoring physiologic lumbosacral geometry and S2 sacral alar-iliac screw fixation during index surgery. Secondary ISF appears to be effective in reducing pain and physical impairment due to PSIJS. Georg Thieme Verlag KG Stuttgart · New York.
Velazquez, Cayley E; Pasch, Keryn E
2014-04-01
The purpose of this study was to examine how objective measures of attention to food/beverage advertising were associated with the unhealthy food/beverage preferences and choices of children and adolescents. A self-report survey and eye-tracking session were completed by 102 youth (mean age=11.6 years; 56.4% were white; 43.1% were female) between April and November 2010. Participants viewed 40 food/beverage advertisements on a computer and their eye movements were recorded. Objective attention measures included total viewing time, fixation length (time spent viewing characters/logos, unhealthy food/beverage items), and fixation count (number of times an individual stops to examine characters/logos, unhealthy food/beverage items). Food/beverage preferences and choices were measured by self-report. The preferences index summed responses to 12 questions measuring snack food and sugar-sweetened beverage preferences and the choices index summed responses to eight questions measuring consumption of snack foods and sugar-sweetened beverages. Regression models examined whether attention to food/beverage advertising was associated with food preferences and choices, controlling for sex, age, and body mass index z score. The length of time and number of times participants looked at unhealthy food and beverage items within advertisements were each significantly associated with unhealthy food/beverage preferences of youth (P<0.05). Associations were no longer significant after controlling for demographic characteristics. Attention to advertising was not significantly associated with food/beverage choices. Research with larger samples is needed to more fully understand the role of attention. Future research should also examine the association between attention to advertising and purchase requests, given the important role of parents in the decision-making process surrounding food choice. Copyright © 2014 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.
Management of Late Onset Perthes: Evaluation of Distraction by External Fixator—5-Year Follow-Up
Srivastava, Rajeshwar N.; Shukla, Prashant; Pushkar, Amit; Ali, Sabir
2014-01-01
Background. Hip distraction in Perthes' disease unloads the joint, which negates the harmful effect of the stresses on the articular surfaces, which may promote the sound healing of the area of necrosis. We have examined the effect of arthrodiastasis on the preservation of the femoral head in older children with Perthes' disease. Methods and Materials. Twelve children with age more than 8 years with Perthes' disease of less than one year were treated with hip distraction by a hinged monolateral external fixator. Observation and Results. Mean duration of distraction was 13.9 days. These children were evaluated by clinicoradiological parameters for a mean period of 32.4 months. There was a significant improvement in the range of movements and mean epiphyseal index, but the change in the percentage of uncovered head femur was insignificant. There was significant improvement in Harris Hip score. Conclusions. Hip distraction by hinged monolateral external fixator seems to be a valid treatment option in cases with Perthes' disease in the selected group of patients, where poor results are expected from conventional treatment. PMID:25580302
Analysis of usage and associated cost of external fixators at an urban level 1 trauma centre.
Chaus, George W; Dukes, Chase; Hak, David J; Mauffrey, Cyril; Mark Hammerberg, E
2014-10-01
To determine the usage, indication, duration, and cost associated with external fixation usage. Additionally, to show the significant cost associated with external fixator use and reinvigorate discussions on external fixator reuse. A retrospective review of a prospectively gathered trauma database was undertaken to identify all patients treated with external fixation frames for pelvic and lower extremity injuries between September 2007 and July 2010. We noted the indications for frame use, and we determined the average duration of external fixation for each indication. The cost of each frame was calculated from implant records. 341 lower extremity and pelvic fractures were treated with external fixation frames during the study period. Of these, 92% were used as temporary external fixation. The average duration of temporary external fixation was 10.5 days. The cost of external fixation frame components was $670,805 per year. The average cost per external fixation frame was $5900. The majority of external fixators are intended as temporary frames, in place for a limited period of time prior to definitive fixation of skeletal injuries. As such, most frames are not intended to withstand physiologic loads, nor are they expected provide a precise maintenance of reduction. Given the considerable expense associated with external fixation frame components, the practice of purchasing external fixation frame components as disposable "single-use" items appears to be somewhat wasteful. Level II. Copyright © 2014 Elsevier Ltd. All rights reserved.
Coral lipids and environmental stress.
Harriott, V J
1993-04-01
Environmental monitoring of coral reefs is presently limited by difficulties in recognising coral stress, other than by monitoring coral mortality over time. A recent report described an experiment demonstrating that a measured lipid index declined in shaded corals. The technique described might have application in monitoring coral health, with a decline in coral lipid index as an indicator of coral stress. The application of the technique as a practical monitoring tool was tested for two coral species from the Great Barrier Reef. Consistent with the previous results, lipid index for Pocillopora damicornis initially declined over a period of three weeks in corals maintained in filtered seawater in the dark, indicating possible utilization of lipid stored as energy reserves. However, lipid index subsequently rose to near normal levels. In contrast, lipid index of Acropora formosa increased after four weeks in the dark in filtered seawater. The results showed considerable variability in lipid content between samples from the same colony. Results were also found to be dependent on fixation times and sample weight, introducing potential error into the practical application of the technique. The method as described would be unsuitable for monitoring environmental stress in corals, but the search for a practical method to monitor coral health should continue, given its importance in coral reef management.
NASA Astrophysics Data System (ADS)
Van Wambeke, F.; Pfreundt, U.; Barani, A.; Berthelot, H.; Moutin, T.; Rodier, M.; Hess, W. R.; Bonnet, S.
2015-12-01
N2 fixation fuels ~ 50 % of new primary production in the oligotrophic South Pacific Ocean. The VAHINE mesocosm experiment designed to track the fate of diazotroph derived nitrogen (DDN) in the New Caledonia lagoon. Here, we examined the temporal dynamics of heterotrophic bacterial production during this experiment. Three replicate large-volume (~ 50 m3) mesocosms were deployed and were intentionally fertilized with dissolved inorganic phosphorus (DIP) to stimulate N2 fixation. We specifically examined relationships between N2 fixation rates and primary production, determined bacterial growth efficiency and established carbon budgets of the system from the DIP fertilization to the end of the experiment (days 5-23). Heterotrophic bacterioplankton production (BP) and alkaline phosphatase activity (APA) were statistically higher during the second phase of the experiment (P2: days 15-23), when chlorophyll biomass started to increase compared to the first phase (P1: days 5-14). Among autotrophs, Synechococcus abundances increased during P2, possibly related to its capacity to assimilate leucine and to produce alkaline phosphatase. Bacterial growth efficiency based on the carbon budget was notably higher than generally cited for oligotrophic environments (27-43 %), possibly due to a high representation of proteorhodopsin-containing organisms within the picoplanctonic community. The carbon budget showed that the main fate of gross primary production (particulate + dissolved) was respiration (67 %), and export through sedimentation (17 %). BP was highly correlated with particulate primary production and chlorophyll biomass during both phases of the experiment but slightly correlated, and only during P2 phase, with N2 fixation rates. Our results suggest that most of the DDN reached the heterotrophic bacterial community through indirect processes, like mortality, lysis and grazing.
Ramoutar, D N; Kodumuri, P; Rodrigues, J N; Olewicz, S; Moran, C G; Ollivere, B J; Forward, D P
2017-02-01
Proximal femoral fractures in adults under 50 years are not as common as in the elderly, but may have just as significant an impact. There is little in the literature describing the functional outcomes of fixation in this age group. Our aim was to assess the clinical and functional outcomes of operative management of extracapsular proximal femoral fractures (AO 31-A) in the young adult (<50 years). Consecutive skeletally mature patients <50 years undergoing operative fixation of these fractures were obtained from a prospective database over a 12-year period. Complications and mortality data were obtained from this database and case note review. Outcome scores were obtained via postal questionnaires. Eighty-eight patients were included in the study of which 74 (84%) had fixation with the dynamic hip screw. The mean age was 39 years (range 17-50) with a male preponderance (73.8%). Mean hospital stay was 14 days (range 2-94). Seventeen (19.3%) patients had died at a mean of 40 months from their operation date. The 1-year mortality was 4.5%. There were five complications (5.7%). SF-36 and EuroQol 5D scores showed that 5-10% had severe problems with a 20% decrease in quality of life compared to population norms. The biggest differences were in the physical function modalities. One-third had fair to poor hip function as assessed by the Oxford Hip Score. Though these injuries are relatively rare in this age group, they do have significant mortality and functional impairment reflecting a higher energy of injury rather than the frailty seen in the elderly.
A mechanistic, globally-applicable model of plant nitrogen uptake, retranslocation and fixation
NASA Astrophysics Data System (ADS)
Fisher, J. B.; Tan, S.; Malhi, Y.; Fisher, R. A.; Sitch, S.; Huntingford, C.
2008-12-01
Nitrogen is one of the nutrients that can most limit plant growth, and nitrogen availability may be a controlling factor on biosphere responses to climate change. We developed a plant nitrogen assimilation model based on a) advective transport through the transpiration stream, b) retranslocation whereby carbon is expended to resorb nitrogen from leaves, c) active uptake whereby carbon is expended to acquire soil nitrogen, and d) biological nitrogen fixation whereby carbon is expended for symbiotic nitrogen fixers. The model relies on 9 inputs: 1) net primary productivity (NPP), 2) plant C:N ratio, 3) available soil nitrogen, 4) root biomass, 5) transpiration rate, 6) saturated soil depth,7) leaf nitrogen before senescence, 8) soil temperature, and 9) ability to fix nitrogen. A carbon cost of retranslocation is estimated based on leaf nitrogen and compared to an active uptake carbon cost based on root biomass and available soil nitrogen; for nitrogen fixers both costs are compared to a carbon cost of fixation dependent on soil temperature. The NPP is then allocated to optimize growth while maintaining the C:N ratio. The model outputs are total plant nitrogen uptake, remaining NPP available for growth, carbon respired to the soil and updated available soil nitrogen content. We test and validate the model (called FUN: Fixation and Uptake of Nitrogen) against data from the UK, Germany and Peru, and run the model under simplified scenarios of primary succession and climate change. FUN is suitable for incorporation into a land surface scheme of a General Circulation Model and will be coupled with a soil model and dynamic global vegetation model as part of a land surface model (JULES).
Global terrestrial carbon and nitrogen cycling insensitive to estimates of biological N fixation
NASA Astrophysics Data System (ADS)
Steinkamp, J.; Weber, B.; Werner, C.; Hickler, T.
2015-12-01
Dinitrogen (N2) is the most abundant molecule in the atmosphere and incorporated in other molecules an essential nutrient for life on earth. However, only few natural processes can initiate a reaction of N2. These natural processes are fire, lightning and biological nitrogen fixation (BNF) with BNF being the largest source. In the course of the last century humans have outperformed the natural processes of nitrogen fixation by the production of fertilizer. Industrial and other human emission of reactive nitrogen, as well as fire and lightning lead to a deposition of 63 Tg (N) per year. This is twice the amount of BNF estimated by the default setup of the dynamic global vegetation model LPJ-GUESS (30 Tg), which is a conservative approach. We use different methods and parameterizations for BNF in LPJ-GUESS: 1.) varying total annual amount; 2.) annual evenly distributed and daily calculated fixation rates; 3.) an improved dataset of BNF by cryptogamic covers (free-living N-fixers). With this setup BNF is ranging from 30 Tg to 60 Tg. We assess the impact of BNF on carbon storage and grand primary production (GPP) of the natural vegetation. These results are compared to and evaluated against available independent datasets. We do not see major differences in the productivity and carbon stocks with these BNF estimates, suggesting that natural vegetation is insensitive to BNF on a global scale and the vegetation can compensate for the different nitrogen availabilities. Current deposition of nitrogen compounds and internal cycling through mineralization and uptake is sufficient for natural vegetation productivity. However, due to the coarse model grid and spatial heterogeneity in the real world this conclusion does not exclude the existence of habitats constrained by BNF.
Fixation distance and fixation duration to vertical road signs.
Costa, Marco; Simone, Andrea; Vignali, Valeria; Lantieri, Claudio; Palena, Nicola
2018-05-01
The distance of first-fixation to vertical road signs was assessed in 22 participants while driving a route of 8.34 km. Fixations to road signs were recorded by a mobile eye-movement-tracking device synchronized to GPS and kinematic data. The route included 75 road signs. First-fixation distance and fixation duration distributions were positively skewed. Median distance of first-fixation was 51 m. Median fixation duration was 137 ms with a modal value of 66 ms. First-fixation distance was linearly related to speed and fixation duration. Road signs were gazed at a much closer distance than their visibility distance. In a second study a staircase procedure was used to test the presentation-time threshold that lead to a 75% accuracy in road sign identification. The threshold was 35 ms, showing that short fixations to a road signs could lead to a correct identification. Copyright © 2018 Elsevier Ltd. All rights reserved.
Zhu, Zhonglin; Ding, Hui; Shao, Hongyi; Zhou, Yixin; Wang, Guangzhi
2013-04-09
The wire fixation and the cable grip fixation have been developed for the extended trochanteric osteotomy (ETO) in the revision of total hip arthroplasty (THA). Many studies reported the postoperative performance of the patients, but with little quantitative biomechanical comparison of the two fixation systems. An in-vitro testing approach was designed to record the loosening between the femoral bed and the greater trochanter after fixations. Ten cadaveric femurs were chosen in this study. Each femur underwent the THA, revision by ETO and fixations. The tension to the greater trochanter was from 0 to 500N in vertical and lateral direction, respectively. The translation and rotation of the greater trochanter with respect to the bony bed were captured by an optical tracking system. In the vertical tension tests, the overall translation of the greater trochanter was observed 0.4 mm in the cable fixations and 7.0 mm in the wire fixations. In the lateral tension tests, the overall motion of the greater trochanter was 2.0 mm and 1.2° in the cable fixations, while it was 6.2 mm and 5.3° in the wire fixations. The result was significantly different between the two fixation systems. The stability of the proximal femur after ETO using different fixations in the revision THA was investigated. The cable grip fixation was significantly more stable than the wire fixation.
Matgé, Guy; Berthold, Christophe; Gunness, Vimal Raj Nitish; Hana, Ardian; Hertel, Frank
2015-03-01
Although cervical total disc replacement (TDR) has shown equivalence or superiority to anterior cervical discectomy and fusion (ACDF), potential problems include nonphysiological motion (hypermobility), accelerated degeneration of the facet joints, particulate wear, and compromise of the mechanical integrity of the endplate during device fixation. Dynamic cervical stabilization is a novel motion-preserving concept that facilitates controlled, limited flexion and extension, but prevents axial rotation and lateral bending, thereby reducing motion across the facet joints. Shock absorption of the Dynamic Cervical Implant (DCI) device is intended to protect adjacent levels from accelerated degeneration. The authors conducted a prospective evaluation of 53 consecutive patients who underwent DCI stabilization for the treatment of 1-level (n = 42), 2-level (n = 9), and 3-level (n = 2) cervical disc disease with radiculopathy or myelopathy. Forty-seven patients (89%) completed all clinical and radiographic outcomes at a minimum of 24 months. Clinical outcomes consisted of Neck Disability Index (NDI) and visual analog scale (VAS) scores, neurological function at baseline and at latest follow-up, as well as patient satisfaction. Flexion-extension radiography was evaluated for device motion, implant migration, subsidence, and heterotopic ossification. Cervical sagittal alignment (Cobb angle), functional spinal unit (FSU) angle, and range of motion (ROM) at index and adjacent levels were evaluated with WEB 1000 software. The NDI score, VAS neck and arm pain scores, and neurological deficits were significantly reduced at each postoperative time point compared with baseline (p < 0.0001). At 24 months postoperatively, 91% of patients were very satisfied and 9% somewhat satisfied, while 89% would definitely and 11% would probably elect to have the same surgery again. In 47 patients with 58 operated levels, the radiographic assessment showed good motion (5°-12°) of the device in 57%, reduced motion (2°-5°) in 34.5%, and little motion (0-2°) in 8.5%. The Cobb and FSU angles improved, showing a clear tendency for lordosis with the DCI. Motion greater than 2° of the treated segment could be preserved in 91.5%, while 8.5% had a near segmental fusion. Mean ROM at index levels demonstrated satisfying motion preservation with DCI. Mean ROM at upper and lower adjacent levels showed maintenance of adjacent-level kinematics. Heterotopic ossification, including 20% minor and 15% major, had no direct impact on clinical results. There were 2 endplate subsidences detected with an increased segmental lordosis. One asymptomatic anterior device migration required reoperation. Three patients underwent a secondary surgery in another segment during follow-up, twice for a new disc herniation and once for an adjacent degeneration. There was no posterior migration and no device breakage. Preliminary results indicate that the DCI implanted using a proper surgical technique is safe and facilitates excellent clinical outcomes, maintains index-and adjacent-level ROM in the majority of cases, improves sagittal alignment, and may be suitable for patients with facet arthrosis who would otherwise not be candidates for cervical TDR. Shock absorption together with maintained motion in the DCI may protect adjacent levels from early degeneration in longer follow-up.
Sabonghy, Eric Peter; Wood, Robert Michael; Ambrose, Catherine Glauber; McGarvey, William Christopher; Clanton, Thomas Oscar
2003-03-01
Tendon transfer techniques in the foot and ankle are used for tendon ruptures, deformities, and instabilities. This fresh cadaver study compares the tendon fixation strength in 10 paired specimens by performing a tendon to tendon fixation technique or using 7 x 20-25 mm bioabsorbable interference-fit screw tendon fixation technique. Load at failure of the tendon to tendon fixation method averaged 279N (Standard Deviation 81N) and the bioabsorbable screw 148N (Standard Deviation 72N) [p = 0.0008]. Bioabsorbable interference-fit screws in these specimens show decreased fixation strength relative to the traditional fixation technique. However, the mean bioabsorbable screw fixation strength of 148N provides physiologic strength at the tendon-bone interface.
Zha, Guo-Chun; Sun, Jun-Ying; Dong, Sheng-Jie; Zhang, Wen; Luo, Zong-Ping
2015-01-01
This study aims to assess the biomechanical properties of a novel fixation system (named AFRIF) and to compare it with other five different fixation techniques for quadrilateral plate fractures. This in vitro biomechanical experiment has shown that the multidirectional titanium fixation (MTF) and pelvic brim long screws fixation (PBSF) provided the strongest fixation for quadrilateral plate fracture; the better biomechanical performance of the AFRIF compared with the T-shaped plate fixation (TPF), L-shaped plate fixation (LPF), and H-shaped plate fixation (HPF); AFRIF gives reasonable stability of treatment for quadrilateral plate fracture and may offer a better solution for comminuted quadrilateral plate fractures or free floating medial wall fracture and be reliable in preventing protrusion of femoral head. PMID:25802849
NASA Astrophysics Data System (ADS)
Mazur, Alexey K.
1999-07-01
Internal coordinate molecular dynamics (ICMD) is a recent efficient method for modeling polymer molecules which treats them as chains of rigid bodies rather than ensembles of point particles as in Cartesian MD. Unfortunately, it is readily applicable only to linear or tree topologies without closed flexible loops. Important examples violating this condition are sugar rings of nucleic acids, proline residues in proteins, and also disulfide bridges. This paper presents the first complete numerical solution of the chain closure problem within the context of ICMD. The method combines natural implicit fixation of bond lengths and bond angles by the choice of internal coordinates with explicit constraints similar to Cartesian dynamics used to maintain the chain closure. It is affordable for large molecules and makes possible 3-5 times faster dynamics simulations of molecular systems with flexible rings, including important biological objects like nucleic acids and disulfide-bonded proteins.
Login, G R; Leonard, J B; Dvorak, A M
1998-06-01
Rapid and reproducible fixation of brain and peripheral nerve tissue for light and electron microscopy studies can be done in a microwave oven. In this review we report a standardized nomenclature for diverse fixation techniques that use microwave heating: (1) microwave stabilization, (2) fast and ultrafast primary microwave-chemical fixation, (3) microwave irradiation followed by chemical fixation, (4) primary chemical fixation followed by microwave irradiation, and (5) microwave fixation used in various combinations with freeze fixation. All of these methods are well suited to fix brain tissue for light microscopy. Fast primary microwave-chemical fixation is best for immunoelectron microscopy studies. We also review how the physical characteristics of the microwave frequency and the dimensions of microwave oven cavities can compromise microwave fixation results. A microwave oven can be calibrated for fixation when the following parameters are standardized: irradiation time; water load volume, initial temperature, and placement within the oven; fixative composition, volume, and initial temperature; and specimen container shape and placement within the oven. Using two recently developed calibration tools, the neon bulb array and the agar-saline-Giemsa tissue phantom, we report a simple calibration protocol that identifies regions within a microwave oven for uniform microwave fixation. Copyright 1998 Academic Press.
Assessing the Added Value of Dynamical Downscaling Using the Standardized Precipitation Index
In this study, the Standardized Precipitation Index (SPI) is used to ascertain the added value of dynamical downscaling over the contiguous United States. WRF is used as a regional climate model (RCM) to dynamically downscale reanalysis fields to compare values of SPI over drough...
Application of alternative fixatives to formalin in diagnostic pathology
Gatta, L. Benerini; Cadei, M.; Balzarini, P.; Castriciano, S.; Paroni, R.; Verzeletti, A.; Cortellini, V.; De Ferrari, F.; Grigolato, P.
2012-01-01
Fixation is a critical step in the preparation of tissues for histopathology. The aim of this study was to investigate the effects of different fixatives vs formalin on proteins and DNA, and to evaluate alternative fixation for morphological diagnosis and nucleic acid preservation for molecular methods. Forty tissues were fixed for 24 h with six different fixatives: the gold standard fixative formalin, the historical fixatives Bouin and Hollande, and the alternative fixatives Greenfix, UPM and CyMol. Tissues were stained (Haematoxylin-Eosin, Periodic Acid Schiff, Trichromic, Alcian-blue, High Iron Diamine stainings), and their antigenicity was determined by immunohistochemistry (performed with PAN-CK, CD31, Ki-67, S100, CD68, AML antibodies). DNA extraction, KRAS sequencing, FISH for CEP-17, and flow cytometry analysis of nuclear DNA content were applied. For cell morphology the alternative fixatives (Greenfix, UPM, CyMol) were equivalent to formalin. As expected, Hollande proved to be the best fixative for morphology. The morphology obtained with Bouin was comparable to the one with formalin. Hollande was the best fixative for histochemistry. Bouin proved to be equivalent to formalin. The alternative fixatives were equivalent to formalin, although with greater variability in haematoxylin-eosin staining. It proved the possibility to obtain immunohistochemical staining largely equivalent to that following formalin-fixation with the following fixatives: Greenfix, Hollande, UPM and CyMol. The tissues fixed in Bouin did not provide results comparable to those obtained with formalin. The DNA extracted from samples fixed with alternative fixatives was found to be suitable for molecular analysis. PMID:22688293
Otero-Arnaiz, Adriana; Casas, Alejandro; Hamrick, James L; Cruse-Sanders, Jennifer
2005-05-01
Polaskia chichipe is a columnar cactus under artificial selection in central Mexico because of its edible fruits. Our study explored the effect of human manipulation on levels and distribution of genetic variation in wild, silviculturally managed and cultivated sympatric populations. Total genetic variation, estimated in nine populations with five microsatellite loci, was H(T) = 0.658 +/- 0.026 SE, which was mainly distributed within populations (H(S) = 0.646) with low differentiation among them (F(ST) = 0.015). Fixation index (F(IS)) in all populations was positive, indicating a deficit of heterozygous individuals with respect to Hardy-Weinberg expectations. When populations were pooled by management type, the highest expected heterozygosity (H(E) = 0.631 +/- 0.031 SE) and the lowest fixation index (F(IS) = 0.07) were observed in wild populations, followed by cultivated populations (H(E) = 0.56 +/- 0.03 SE, F(IS) = 0.14), whereas the lowest variation was found in silviculturally managed populations (H(E) = 0.51 +/- 0.05 SE, F(IS) = 0.17). Low differentiation among populations under different management types (F(ST) 0.005, P < 0.04) was observed. A pattern of migration among neighbouring populations, suggested from isolation by distance (r2 = 0.314, P < 0.01), may have contributed to homogenizing populations and counteracting the effects of artificial selection. P. chichipe, used and managed for at least 700 generations, shows morphological differentiation, changes in breeding system and seed germination patterns associated with human management, with only slight genetic differences detected by neutral markers.
Risk factors for acute surgical site infections after lumbar surgery: a retrospective study.
Lai, Qi; Song, Quanwei; Guo, Runsheng; Bi, Haidi; Liu, Xuqiang; Yu, Xiaolong; Zhu, Jianghao; Dai, Min; Zhang, Bin
2017-07-19
Currently, many scholars are concerned about the treatment of postoperative infection; however, few have completed multivariate analyses to determine factors that contribute to the risk of infection. Therefore, we conducted a multivariate analysis of a retrospectively collected database to analyze the risk factors for acute surgical site infection following lumbar surgery, including fracture fixation, lumbar fusion, and minimally invasive lumbar surgery. We retrospectively reviewed data from patients who underwent lumbar surgery between 2014 and 2016, including lumbar fusion, internal fracture fixation, and minimally invasive surgery in our hospital's spinal surgery unit. Patient demographics, procedures, and wound infection rates were analyzed using descriptive statistics, and risk factors were analyzed using logistic regression analyses. Twenty-six patients (2.81%) experienced acute surgical site infection following lumbar surgery in our study. The patients' mean body mass index, smoking history, operative time, blood loss, draining time, and drainage volume in the acute surgical site infection group were significantly different from those in the non-acute surgical site infection group (p < 0.05). Additionally, diabetes mellitus, chronic obstructive pulmonary disease, osteoporosis, preoperative antibiotics, type of disease, and operative type in the acute surgical site infection group were significantly different than those in the non-acute surgical site infection group (p < 0.05). Using binary logistic regression analyses, body mass index, smoking, diabetes mellitus, osteoporosis, preoperative antibiotics, fracture, operative type, operative time, blood loss, and drainage time were independent predictors of acute surgical site infection following lumbar surgery. In order to reduce the risk of infection following lumbar surgery, patients should be evaluated for the risk factors noted above.
A unified dynamic neural field model of goal directed eye movements
NASA Astrophysics Data System (ADS)
Quinton, J. C.; Goffart, L.
2018-01-01
Primates heavily rely on their visual system, which exploits signals of graded precision based on the eccentricity of the target in the visual field. The interactions with the environment involve actively selecting and focusing on visual targets or regions of interest, instead of contemplating an omnidirectional visual flow. Eye-movements specifically allow foveating targets and track their motion. Once a target is brought within the central visual field, eye-movements are usually classified into catch-up saccades (jumping from one orientation or fixation to another) and smooth pursuit (continuously tracking a target with low velocity). Building on existing dynamic neural field equations, we introduce a novel model that incorporates internal projections to better estimate the current target location (associated to a peak of activity). Such estimate is then used to trigger an eye movement, leading to qualitatively different behaviours depending on the dynamics of the whole oculomotor system: (1) fixational eye-movements due to small variations in the weights of projections when the target is stationary, (2) interceptive and catch-up saccades when peaks build and relax on the neural field, (3) smooth pursuit when the peak stabilises near the centre of the field, the system reaching a fixed point attractor. Learning is nevertheless required for tracking a rapidly moving target, and the proposed model thus replicates recent results in the monkey, in which repeated exercise permits the maintenance of the target within in the central visual field at its current (here-and-now) location, despite the delays involved in transmitting retinal signals to the oculomotor neurons.
Phakic iris-fixated intraocular lens placement in the anterior chamber: effects on aqueous flow.
Repetto, Rodolfo; Pralits, Jan O; Siggers, Jennifer H; Soleri, Paolo
2015-05-01
Phakic intraocular lenses (pIOLs) are used for correcting vision; in this paper we investigate the fluid dynamical effects of an iris-fixated lens in the anterior chamber. In particular, we focus on changes in the wall shear stress (WSS) on the cornea and iris, which could be responsible for endothelial and pigment cell loss, respectively, and also on the possible increase of the intraocular pressure, which is known to correlate with the incidence of secondary glaucoma. We use a mathematical model to study fluid flow in the anterior chamber in the presence of a pIOL. The governing equations are solved numerically using the open source software OpenFOAM. We use an idealized standard geometry for the anterior chamber and a realistic geometric description of the pIOL. We consider separately the main mechanisms that produce fluid flow in the anterior chamber. The numerical simulations allow us to obtain a detailed description of the velocity and pressure distribution in the anterior chamber, and indicated that implantation of the pIOL significantly modifies the fluid dynamics in the anterior chamber. However, lens implantation has negligible influence on the intraocular pressure and does not produce a significant increase of the shear stress on the cornea, while the shear stress on the iris, although increased, is not enough to cause detachment of cells. We conclude that alterations in the fluid dynamics in the anterior chamber as a result of lens implantation are unlikely to be the cause of medical complications associated with its use.
NASA Astrophysics Data System (ADS)
Xu, Kuangyi; Li, Kun; Cong, Rui; Wang, Long
2017-02-01
In the framework of the evolutionary game theory, two fundamentally different mechanisms, the imitation process and the aspiration-driven dynamics, can be adopted by players to update their strategies. In the former case, individuals imitate the strategy of a more successful peer, while in the latter case individuals change their strategies based on a comparison of payoffs they collect in the game to their own aspiration levels. Here we explore how cooperation evolves for the coexistence of these two dynamics. Intriguingly, cooperation reaches its lowest level when a certain moderate fraction of individuals pick aspiration-level-driven rule while the others choose pairwise comparison rule. Furthermore, when individuals can adjust their update rules besides their strategies, either imitation dynamics or aspiration-driven dynamics will finally take over the entire population, and the stationary cooperation level is determined by the outcome of competition between these two dynamics. We find that appropriate synergetic effects and moderate aspiration level boost the fixation probability of aspiration-driven dynamics most effectively. Our work may be helpful in understanding the cooperative behavior induced by the coexistence of imitation dynamics and aspiration dynamics in the society.
[Tibial press-fit fixation of flexor tendons for reconstruction of the anterior cruciate ligament].
Ettinger, M; Liodakis, E; Haasper, C; Hurschler, C; Breitmeier, D; Krettek, C; Jagodzinski, M
2012-09-01
Press-fit fixation of hamstring tendon autografts for anterior cruciate ligament reconstruction is an interesting technique because no hardware is necessary. This study compares the biomechanical properties of press-fit fixations to an interference screw fixation. Twenty-eight human cadaveric knees were used for hamstring tendon explantation. An additional bone block was harvested from the tibia. We used 28 porcine femora for graft fixation. Constructs were cyclically stretched and then loaded until failure. Maximum load to failure, stiffness and elongation during failure testing and cyclic loading were investigated. The maximum load to failure was 970±83 N for the press-fit tape fixation (T), 572±151 N for the bone bridge fixation (TS), 544±109 N for the interference screw fixation (I), 402±77 N for the press-fit suture fixation (S) and 290±74 N for the bone block fixation technique (F). The T fixation had a significantly better maximum load to failure compared to all other techniques (p<0.001). This study demonstrates that a tibial press-fit technique which uses an additional bone block has better maximum load to failure results compared to a simple interference screw fixation.
Rieger, J.; Twardziok, S.; Huenigen, H.; Hirschberg, R.M.; Plendl, J.
2013-01-01
Staining of mast cells (MCs), including porcine ones, is critically dependent upon the fixation and staining technique. In the pig, mucosal and submucosal MCs do not stain or stain only faintly after formalin fixation. Some fixation methods are particularly recommended for MC staining, for example the fixation with Carnoy or lead salts. Zinc salt fixation (ZSF) has been reported to work excellently for the preservation of fixation-sensitive antigens. The aim of this study was to establish a reliable histological method for counting of MCs in the porcine intestinum. For this purpose, different tissue fixation and staining methods that also allow potential subsequent immunohistochemical investigations were evaluated in the porcine mucosa, as well as submucosa of small and large intestine. Tissues were fixed in Carnoy, lead acetate, lead nitrate, Zamboni and ZSF and stained subsequently with either polychromatic methylene blue, alcian blue or toluidine blue. For the first time our study reveals that ZSF, a heavy metal fixative, preserves metachromatic staining of porcine MCs. Zamboni fixation was not suitable for histochemical visualization of MCs in the pig intestine. All other tested fixatives were suitable. Alcian blue and toluidine blue co-stained intestinal goblet cells which made a prima facie identification of MCs difficult. The polychromatic methylene blue proved to be the optimal staining. In order to compare MC counting results of the different fixation methods, tissue shrinkage was taken into account. As even the same fixation caused shrinkagedifferences between tissue from small and large intestine, different factors for each single fixation and intestinal localization had to be calculated. Tissue shrinkage varied between 19% and 57%, the highest tissue shrinkage was found after fixation with ZSF in the large intestine, the lowest one in the small intestine after lead acetate fixation. Our study emphasizes that MC counting results from data using different fixation techniques can only be compared if the respective studyimmanent shrinkage factor has been determined and quantification results are adjusted accordingly. PMID:24085270
Fascione, Jeanna M; Crews, Ryan T; Wrobel, James S
2012-01-01
Identifying the variability of footprint measurement collection techniques and the reliability of footprint measurements would assist with appropriate clinical foot posture appraisal. We sought to identify relationships between these measures in a healthy population. On 30 healthy participants, midgait dynamic footprint measurements were collected using an ink mat, paper pedography, and electronic pedography. The footprints were then digitized, and the following footprint indices were calculated with photo digital planimetry software: footprint index, arch index, truncated arch index, Chippaux-Smirak Index, and Staheli Index. Differences between techniques were identified with repeated-measures analysis of variance with post hoc test of Scheffe. In addition, to assess practical similarities between the different methods, intraclass correlation coefficients (ICCs) were calculated. To assess intrarater reliability, footprint indices were calculated twice on 10 randomly selected ink mat footprint measurements, and the ICC was calculated. Dynamic footprint measurements collected with an ink mat significantly differed from those collected with paper pedography (ICC, 0.85-0.96) and electronic pedography (ICC, 0.29-0.79), regardless of the practical similarities noted with ICC values (P = .00). Intrarater reliability for dynamic ink mat footprint measurements was high for the footprint index, arch index, truncated arch index, Chippaux-Smirak Index, and Staheli Index (ICC, 0.74-0.99). Footprint measurements collected with various techniques demonstrate differences. Interchangeable use of exact values without adjustment is not advised. Intrarater reliability of a single method (ink mat) was found to be high.
Safaee, Michael M; Dalle Ore, Cecilia L; Zygourakis, Corinna C; Deviren, Vedat; Ames, Christopher P
2018-05-01
OBJECTIVE Proximal junctional kyphosis (PJK) is a well-recognized complication of surgery for adult spinal deformity and is characterized by increased kyphosis at the upper instrumented vertebra (UIV). PJK prevention strategies have the potential to decrease morbidity and cost by reducing rates of proximal junctional failure (PJF), which the authors define as radiographic PJK plus clinical sequelae requiring revision surgery. METHODS The authors performed an analysis of 195 consecutive patients with adult spinal deformity. Age, sex, levels fused, upper instrumented vertebra (UIV), use of 3-column osteotomy, pelvic fixation, and mean time to follow-up were collected. The authors also reviewed operative reports to assess for the use of surgical adjuncts targeted toward PJK prevention, including ligament augmentation, hook fixation, and vertebroplasty. The cost of surgery, including direct and total costs, was also assessed at index surgery and revision surgery. Only revision surgery for PJF was included. RESULTS The mean age of the cohort was 64 years (range 25-84 years); 135 (69%) patients were female. The mean number of levels fused was 10 (range 2-18) with the UIV as follows: 2 cervical (1%), 73 upper thoracic (37%), 108 lower thoracic (55%), and 12 lumbar (6%). Ligament augmentation was used in 99 cases (51%), hook fixation in 60 cases (31%), and vertebroplasty in 71 cases (36%). PJF occurred in 18 cases (9%). Univariate analysis found that ligament augmentation and hook fixation were associated with decreased rates of PJF. However, in a multivariate model that also incorporated age, sex, and UIV, only ligament augmentation maintained a significant association with PJF reduction (OR 0.196, 95% CI 0.050-0.774; p = 0.020). Patients with ligament augmentation, compared with those without, had a higher cost of index surgery, but ligament augmentation was overall cost effective and produced significant cost savings. In sensitivity analyses in which we independently varied the reduction in PJF, cost of ligament augmentation, and cost of reoperation by ± 50%, ligament augmentation remained a cost-effective strategy for PJF prevention. CONCLUSIONS Prevention strategies for PJK/PJF are limited, and their cost-effectiveness has yet to be established. The authors present the results of 195 patients with adult spinal deformity and show that ligament augmentation is associated with significant reductions in PJF in both univariate and multivariate analyses, and that this intervention is cost-effective. Future studies will need to determine if these clinical results are reproducible, but for high-risk cases, these data suggest an important role of ligament augmentation for PJF prevention and cost savings.
Dynamic scanpaths: eye movement analysis methods
NASA Astrophysics Data System (ADS)
Blackmon, Theodore T.; Ho, Yeuk F.; Chernyak, Dimitri A.; Azzariti, Michela; Stark, Lawrence W.
1999-05-01
An eye movements sequence, or scanpath, during viewing of a stationary stimulus has been described as a set of fixations onto regions-of-interest, ROIs, and the saccades or transitions between them. Such scanpaths have high similarity for the same subject and stimulus both in the spatial loci of the ROIs and their sequence; scanpaths also take place during recollection of a previously viewed stimulus, suggesting that they play a similar role in visual memory and recall.
Borys, Jan; Maciejczyk, Mateusz; Krȩtowski, Adam J.; Antonowicz, Bozena; Ratajczak-Wrona, Wioletta; Jabłońska, Ewa; Załęski, Piotr; Waszkiel, Danuta; Ładny, Jerzy R.; Żukowski, Piotr; Zalewska, Anna
2017-01-01
Titanium miniplates and screws are commonly used for fixation of jaw fractured or osteotomies. Despite the opinion of their biocompatibility, in clinical practice symptoms of chronic inflammation around the fixation develop in some patients, even many years after the application of miniplates and screws. The cause of these complications is still an unanswered question. Taking into account that oxidative stress is one of the toxic action of titanium, we have evaluated the antioxidant barrier as well as oxidative stress in the erythrocytes, plasma and periosteum covering the titanium fixation of the jaw. The study group was composed of 32 patients aged 20–30 with inserted miniplates and screws. The antioxidant defense: catalase (CAT), glutathione peroxidase (GPx), superoxide dismutase-1 (SOD1), uric acid (UA), total antioxidant capacity (TAC), as well as oxidative damage products: advanced oxidation protein products (AOPP), advanced glycation end products (AGE), dityrosine, kynurenine, N-formylkynurenine, tryptophan, malondialdehyde (MDA), 4-hydroxynonenal (4-HNE), total oxidant status (TOS), and oxidative status index (OSI) were evaluated. SOD1 activity (↓37%), and tryptophan levels (↓34%) showed a significant decrease while AOPP (↑25%), TOS (↑80%) and OSI (↑101%) were significantly elevated in maxillary periosteum of patients who underwent bimaxillary osteotomies as compared to the control group. SOD-1 (↓55%), TAC (↓58.6%), AGE (↓60%) and N-formylkynurenine (↓34%) was statistically reduced while AOPP (↑38%), MDA (↑29%), 4-HNE (↑114%), TOS (↑99%), and OSI (↑381%) were significantly higher in the mandibular periosteum covering miniplates/screw compared with the control tissues. There were no correlations between antioxidants and oxidative stress markers in the periosteum of all patients and the blood. As exposure to the Ti6Al4V titanium alloy leads to disturbances of redox balance in the periosteum surrounding titanium implants of the maxilla and the mandible so antioxidant supplementation should be recommended to the patients undergoing treatment of dentofacial deformities with the use of titanium implants. The results we obtained may also indicate a need to improve the quality of titanium jaw fixations through increase of TiO2 passivation layer thickness or to develop new, the most highly biodegradable materials for their production. PMID:28638348
Seyhan, Mustafa; Donmez, Ferdi; Mahirogullari, Mahir; Cakmak, Selami; Mutlu, Serhat; Guler, Olcay
2015-07-01
17 patients with ankle syndesmosic injury were treated with a 4.5mm single cortical screw fixation (passage of screw 4 cortices) and 15 patients were treated with single-level elastic fixation material. All patients were evaluated according to the AOFAS ankle and posterior foot scale at the third, sixth and twelfth months after the fixation. The ankle range of movement was recorded together with the healthy side. The Student's t test was used for statistical comparisons. No statistical significant difference was observed between the AOFAS scores (p>0.05). The range of dorsiflexion and plantar flexion motion of the elastic fixation group at the 6th and 12th months were significantly better compared to the screw fixation group (p<0.01). Elastic fixation is as functional as screw fixation in the treatment of ankle syndesmosis injuries. The unnecessary need of a second surgical intervention for removal of the fixation material is another advantageous aspect of this method of fixation. Copyright © 2015. Published by Elsevier Ltd.
Nitrogen limitation on land: how can it occur in Earth system models?
Thomas, R Quinn; Brookshire, E N Jack; Gerber, Stefan
2015-05-01
The representation of the nitrogen (N) cycle in Earth system models (ESMs) is strongly motivated by the constraint N poses on the sequestration of anthropogenic carbon (C). Models typically implement a stoichiometric relationship between C and N in which external supply and assimilation by organisms are adjusted to maintain their internal stoichiometry. N limitation of primary productivity thus occurs if the N supply from uptake and fixation cannot keep up with the construction of tissues allowed by C assimilation. This basic approach, however, presents considerable challenges in how to faithfully represent N limitation. Here, we review how N limitation is currently implemented and evaluated in ESMs and highlight challenges and opportunities in their future development. At or near steady state, N limitation is governed by the magnitude of losses from the plant-unavailable pool vs. N fixation and there are considerable differences in how models treat both processes. In nonsteady-state systems, the accumulation of N in pools with slow turnover rates reduces N available for plant uptake and can be challenging to represent when initializing ESM simulations. Transactional N limitation occurs when N is incorporated into various vegetation and soil pools and becomes available to plants only after it is mineralized, the dynamics of which depends on how ESMs represent decomposition processes in soils. Other challenges for ESMs emerge when considering seasonal to interannual climatic oscillations as they create asynchronies between C and N demand, leading to transient alternations between N surplus and deficit. Proper evaluation of N dynamics in ESMs requires conceptual understanding of the main levers that trigger N limitation, and we highlight key measurements and observations that can help constrain these levers. Two of the biggest challenges are the mechanistic representation of plant controls on N availability and turnover, including N fixation and organic matter decomposition processes. © 2015 John Wiley & Sons Ltd.
A Subconscious Interaction between Fixation and Anticipatory Pursuit
Bal, Japjot; Heinen, Stephen J.
2017-01-01
Ocular smooth pursuit and fixation are typically viewed as separate systems, yet there is evidence that the brainstem fixation system inhibits pursuit. Here we present behavioral evidence that the fixation system modulates pursuit behavior outside of conscious awareness. Human observers (male and female) either pursued a small spot that translated across a screen, or fixated it as it remained stationary. As shown previously, pursuit trials potentiated the oculomotor system, producing anticipatory eye velocity on the next trial before the target moved that mimicked the stimulus-driven velocity. Randomly interleaving fixation trials reduced anticipatory pursuit, suggesting that a potentiated fixation system interacted with pursuit to suppress eye velocity in upcoming pursuit trials. The reduction was not due to passive decay of the potentiated pursuit signal because interleaving “blank” trials in which no target appeared did not reduce anticipatory pursuit. Interspersed short fixation trials reduced anticipation on long pursuit trials, suggesting that fixation potentiation was stronger than pursuit potentiation. Furthermore, adding more pursuit trials to a block did not restore anticipatory pursuit, suggesting that fixation potentiation was not overridden by certainty of an imminent pursuit trial but rather was immune to conscious intervention. To directly test whether cognition can override fixation suppression, we alternated pursuit and fixation trials to perfectly specify trial identity. Still, anticipatory pursuit did not rise above that observed with an equal number of random fixation trials. The results suggest that potentiated fixation circuitry interacts with pursuit circuitry at a subconscious level to inhibit pursuit. SIGNIFICANCE STATEMENT When an object moves, we view it with smooth pursuit eye movements. When an object is stationary, we view it with fixational eye movements. Pursuit and fixation are historically regarded as controlled by different neural circuitry, and alternating between invoking them is thought to be guided by a conscious decision. However, our results show that pursuit is actively suppressed by prior fixation of a stationary object. This suppression is involuntary, and cannot be avoided even if observers are certain that the object will move. The results suggest that the neural fixation circuitry is potentiated by engaging stationary objects, and interacts with pursuit outside of conscious awareness. PMID:29061701
A Subconscious Interaction between Fixation and Anticipatory Pursuit.
Watamaniuk, Scott N J; Bal, Japjot; Heinen, Stephen J
2017-11-22
Ocular smooth pursuit and fixation are typically viewed as separate systems, yet there is evidence that the brainstem fixation system inhibits pursuit. Here we present behavioral evidence that the fixation system modulates pursuit behavior outside of conscious awareness. Human observers (male and female) either pursued a small spot that translated across a screen, or fixated it as it remained stationary. As shown previously, pursuit trials potentiated the oculomotor system, producing anticipatory eye velocity on the next trial before the target moved that mimicked the stimulus-driven velocity. Randomly interleaving fixation trials reduced anticipatory pursuit, suggesting that a potentiated fixation system interacted with pursuit to suppress eye velocity in upcoming pursuit trials. The reduction was not due to passive decay of the potentiated pursuit signal because interleaving "blank" trials in which no target appeared did not reduce anticipatory pursuit. Interspersed short fixation trials reduced anticipation on long pursuit trials, suggesting that fixation potentiation was stronger than pursuit potentiation. Furthermore, adding more pursuit trials to a block did not restore anticipatory pursuit, suggesting that fixation potentiation was not overridden by certainty of an imminent pursuit trial but rather was immune to conscious intervention. To directly test whether cognition can override fixation suppression, we alternated pursuit and fixation trials to perfectly specify trial identity. Still, anticipatory pursuit did not rise above that observed with an equal number of random fixation trials. The results suggest that potentiated fixation circuitry interacts with pursuit circuitry at a subconscious level to inhibit pursuit. SIGNIFICANCE STATEMENT When an object moves, we view it with smooth pursuit eye movements. When an object is stationary, we view it with fixational eye movements. Pursuit and fixation are historically regarded as controlled by different neural circuitry, and alternating between invoking them is thought to be guided by a conscious decision. However, our results show that pursuit is actively suppressed by prior fixation of a stationary object. This suppression is involuntary, and cannot be avoided even if observers are certain that the object will move. The results suggest that the neural fixation circuitry is potentiated by engaging stationary objects, and interacts with pursuit outside of conscious awareness. Copyright © 2017 the authors 0270-6474/17/3711424-07$15.00/0.
Population dynamics of HIV-1 inferred from gene sequences.
Grassly, N C; Harvey, P H; Holmes, E C
1999-01-01
A method for the estimation of population dynamic history from sequence data is described and used to investigate the past population dynamics of HIV-1 subtypes A and B. Using both gag and env gene alignments the effective population size of each subtype is estimated and found to be surprisingly small. This may be a result of the selective sweep of mutations through the population, or may indicate an important role of genetic drift in the fixation of mutations. The implications of these results for the spread of drug-resistant mutations and transmission dynamics, and also the roles of selection and recombination in shaping HIV-1 genetic diversity, are discussed. A larger estimated effective population size for subtype A may be the result of differences in time of origin, transmission dynamics, and/or population structure. To investigate the importance of population structure a model of population subdivision was fitted to each subtype, although the improvement in likelihood was found to be nonsignificant. PMID:9927440
Huang, Xiaowei; Zhi, Zhongzheng; Yu, Baoqing; Chen, Fancheng
2015-11-25
The purpose of this study is to compare the stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture. A three-dimensional (3D) finite element model of the medial tibial plateau fracture (Schatzker type IV fracture) was created. An axial force of 2500 N with a distribution of 60% to the medial compartment was applied to simulate the axial compressive load on an adult knee during single-limb stance. The equivalent von Mises stress, displacement of the model relative to the distal tibia, and displacement of the implants were used as the output measures. The mean stress value of the plate-screw fixation system was 18.78 MPa, which was significantly (P < 0.001) smaller than that of the screw fixation system. The maximal value of displacement (sum) in the plate-screw fixation system was 2.46 mm, which was lower than that in the screw fixation system (3.91 mm). The peak stress value of the triangular fragment in the plate-screw fixation system model was 42.04 MPa, which was higher than that in the screw fixation model (24.18 MPa). But the mean stress of the triangular fractured fragment in the screw fixation model was significantly higher in terms of equivalent von Mises stress (EVMS), x-axis, and z-axis (P < 0.001). This study demonstrated that the load transmission mechanism between plate-screw fixation system and screw fixation system was different and the stability provided by the plate-screw fixation system was superior to the screw fixation system.
Sun, Tao
2016-01-01
Introduction Using network meta-analysis, we evaluated the adverse effects of the seven most common treatment methods, i.e., bridging external fixation, non-bridging external fixation, K-wire fixation, plaster fixation, dorsal plating, volar plating, and dorsal and volar plating, by their associated risk of developing complex regional pain syndrome (CRPS) in distal radius fracture (DRF) patients. Material and methods Following an exhaustive search of scientific literature databases for high quality studies, randomized controlled trials (RCTs) related to our study topic were screened and selected based on stringent predefined inclusion and exclusion criteria. Data extracted from the selected studies were used for statistical analyses using Stata 12.0 software. Results A total of 17 RCTs, including 1658 DRF patients, were enrolled in this network meta-analysis. Among the 1658 DRF patients, 452 received bridging external fixation, 525 received non-bridging external fixation, 154 received K-wire fixation, 84 received plaster fixation, 132 received dorsal plating, 123 received volar plating, and 188 received dorsal and volar plating. When compared to bridging external fixation patients, there was no marked difference in the CRPS risk in DRF patients receiving different treatments (all p > 0.05). However, the surface under the cumulative ranking curves (SUCRA) for plaster fixation (77.0%) and non-bridging external fixation (71.3%) were significantly higher compared with the other five methods. Conclusions Our findings suggest that compared with bridging external fixation, K-wire fixation, dorsal plating, volar plating, dorsal and volar plating, plaster fixation and non-bridging external fixation might be the better treatment methods to reduce the risk of CRPS in DRF patients. PMID:28144268
Recent advances in fixation of the craniomaxillofacial skeleton.
Meslemani, Danny; Kellman, Robert M
2012-08-01
Fixation of the craniomaxillofacial skeleton is an evolving aspect for facial plastic, oral and maxillofacial, and plastic surgery. This review looks at the recent advances that aid in reduction and fixation of the craniomaxillofacial skeleton. More surgeons are using resorbable plates for craniomaxillofacial fixation. A single miniplate on the inferior border of the mandible may be sufficient to reduce and fixate an angle fracture. Percutaneous K-wires may assist in plating angle fractures. Intraoperative computed tomography (CT) may prove to be useful for assessing reduction and fixation. Resorbable plates are becoming increasingly popular in orthognathic surgery and facial trauma surgery. There are newer operative techniques for fixating the angle of the mandible. Also, the utilization of the intraoperative CT provides immediate feedback for accurate reduction and fixation. Prebent surgical plates save operative time, decrease errors, and provide more accurate fixation.
Latt, L Daniel; Glisson, Richard R; Adams, Samuel B; Schuh, Reinhard; Narron, John A; Easley, Mark E
2015-10-01
Transverse tarsal joint arthrodesis is commonly performed in the operative treatment of hindfoot arthritis and acquired flatfoot deformity. While fixation is typically achieved using screws, failure to obtain and maintain joint compression sometimes occurs, potentially leading to nonunion. External fixation is an alternate method of achieving arthrodesis site compression and has the advantage of allowing postoperative compression adjustment when necessary. However, its performance relative to standard screw fixation has not been quantified in this application. We hypothesized that external fixation could provide transverse tarsal joint compression exceeding that possible with screw fixation. Transverse tarsal joint fixation was performed sequentially, first with a circular external fixator and then with compression screws, on 9 fresh-frozen cadaveric legs. The external fixator was attached in abutting rings fixed to the tibia and the hindfoot and a third anterior ring parallel to the hindfoot ring using transverse wires and half-pins in the tibial diaphysis, calcaneus, and metatarsals. Screw fixation comprised two 4.3 mm headless compression screws traversing the talonavicular joint and 1 across the calcaneocuboid joint. Compressive forces generated during incremental fixator foot ring displacement to 20 mm and incremental screw tightening were measured using a custom-fabricated instrumented miniature external fixator spanning the transverse tarsal joint. The maximum compressive force generated by the external fixator averaged 186% of that produced by the screws (range, 104%-391%). Fixator compression surpassed that obtainable with screws at 12 mm of ring displacement and decreased when the tibial ring was detached. No correlation was found between bone density and the compressive force achievable by either fusion method. The compression across the transverse tarsal joint that can be obtained with a circular external fixator including a tibial ring exceeds that which can be obtained with 3 headless compression screws. Screw and external fixator performance did not correlate with bone mineral density. This study supports the use of external fixation as an alternative method of generating compression to help stimulate fusion across the transverse tarsal joints. The findings provide biomechanical evidence to support the use of external fixation as a viable option in transverse tarsal joint fusion cases in which screw fixation has failed or is anticipated to be inadequate due to suboptimal bone quality. © The Author(s) 2015.
Hierarchical content-based image retrieval by dynamic indexing and guided search
NASA Astrophysics Data System (ADS)
You, Jane; Cheung, King H.; Liu, James; Guo, Linong
2003-12-01
This paper presents a new approach to content-based image retrieval by using dynamic indexing and guided search in a hierarchical structure, and extending data mining and data warehousing techniques. The proposed algorithms include: a wavelet-based scheme for multiple image feature extraction, the extension of a conventional data warehouse and an image database to an image data warehouse for dynamic image indexing, an image data schema for hierarchical image representation and dynamic image indexing, a statistically based feature selection scheme to achieve flexible similarity measures, and a feature component code to facilitate query processing and guide the search for the best matching. A series of case studies are reported, which include a wavelet-based image color hierarchy, classification of satellite images, tropical cyclone pattern recognition, and personal identification using multi-level palmprint and face features.
Time Savings and Surgery Task Load Reduction in Open Intraperitoneal Onlay Mesh Fixation Procedure.
Roy, Sanjoy; Hammond, Jeffrey; Panish, Jessica; Shnoda, Pullen; Savidge, Sandy; Wilson, Mark
2015-01-01
This study assessed the reduction in surgeon stress associated with savings in procedure time for mechanical fixation of an intraperitoneal onlay mesh (IPOM) compared to a traditional suture fixation in open ventral hernia repair. Nine general surgeons performed 36 open IPOM fixation procedures in porcine model. Each surgeon conducted two mechanical (using ETHICON SECURESTRAP ™ Open) and two suture fixation procedures. Fixation time was measured using a stopwatch, and related surgeon stress was assessed using the validated SURG-TLX questionnaire. T-tests were used to compare between-group differences, and a two-sided 95% confidence interval for the difference in stress levels was established using nonparametric methodology. The mechanical fixation group demonstrated an 89.1% mean reduction in fixation time, as compared to the suture group (p < 0.00001). Surgeon stress scores measured using SURG-TLX were 55.5% lower in the mechanical compared to the suture fixation group (p < 0.001). Scores in five of the six sources of stress were significantly lower for mechanical fixation. Mechanical fixation with ETHICON SECURESTRAP ™ Open demonstrated a significant reduction in fixation time and surgeon stress, which may translate into improved operating efficiency, improved performance, improved surgeon quality of life, and reduced overall costs of the procedure.
Time Savings and Surgery Task Load Reduction in Open Intraperitoneal Onlay Mesh Fixation Procedure
Roy, Sanjoy; Hammond, Jeffrey; Panish, Jessica; Shnoda, Pullen; Savidge, Sandy; Wilson, Mark
2015-01-01
Background. This study assessed the reduction in surgeon stress associated with savings in procedure time for mechanical fixation of an intraperitoneal onlay mesh (IPOM) compared to a traditional suture fixation in open ventral hernia repair. Study Design. Nine general surgeons performed 36 open IPOM fixation procedures in porcine model. Each surgeon conducted two mechanical (using ETHICON SECURESTRAPTM Open) and two suture fixation procedures. Fixation time was measured using a stopwatch, and related surgeon stress was assessed using the validated SURG-TLX questionnaire. T-tests were used to compare between-group differences, and a two-sided 95% confidence interval for the difference in stress levels was established using nonparametric methodology. Results. The mechanical fixation group demonstrated an 89.1% mean reduction in fixation time, as compared to the suture group (p < 0.00001). Surgeon stress scores measured using SURG-TLX were 55.5% lower in the mechanical compared to the suture fixation group (p < 0.001). Scores in five of the six sources of stress were significantly lower for mechanical fixation. Conclusions. Mechanical fixation with ETHICON SECURESTRAPTM Open demonstrated a significant reduction in fixation time and surgeon stress, which may translate into improved operating efficiency, improved performance, improved surgeon quality of life, and reduced overall costs of the procedure. PMID:26240834
Einhäuser, Wolfgang; Nuthmann, Antje
2016-09-01
During natural scene viewing, humans typically attend and fixate selected locations for about 200-400 ms. Two variables characterize such "overt" attention: the probability of a location being fixated, and the fixation's duration. Both variables have been widely researched, but little is known about their relation. We use a two-step approach to investigate the relation between fixation probability and duration. In the first step, we use a large corpus of fixation data. We demonstrate that fixation probability (empirical salience) predicts fixation duration across different observers and tasks. Linear mixed-effects modeling shows that this relation is explained neither by joint dependencies on simple image features (luminance, contrast, edge density) nor by spatial biases (central bias). In the second step, we experimentally manipulate some of these features. We find that fixation probability from the corpus data still predicts fixation duration for this new set of experimental data. This holds even if stimuli are deprived of low-level images features, as long as higher level scene structure remains intact. Together, this shows a robust relation between fixation duration and probability, which does not depend on simple image features. Moreover, the study exemplifies the combination of empirical research on a large corpus of data with targeted experimental manipulations.
Qiu, Wen-Jun; Li, Yi-Fan; Ji, Yun-Han; Xu, Wei; Zhu, Xiao-Dong; Tang, Xian-Zhong; Zhao, Huan-Li; Wang, Gui-Bin; Jia, Yue-Qing; Zhu, Shi-Cai; Zhang, Feng-Fang; Liu, Hong-Mei
2015-01-01
In this study, we performed a network meta-analysis to compare the outcomes of seven most common surgical procedures to fix DRF, including bridging external fixation, non-bridging external fixation, K-wire fixation, plaster fixation, dorsal plating, volar plating, and dorsal and volar plating. Published studies were retrieved through PubMed, Embase and Cochrane Library databases. The database search terms used were the following keywords and MeSH terms: DRF, bridging external fixation, non-bridging external fixation, K-wire fixation, plaster fixation, dorsal plating, volar plating, and dorsal and volar plating. The network meta-analysis was performed to rank the probabilities of postoperative complication risks for the seven surgical modalities in DRF patients. This network meta-analysis included data obtained from a total of 19 RCTs. Our results revealed that compared to DRF patients treated with bridging external fixation, marked differences in pin-track infection (PTI) rate were found in patients treated with plaster fixation, volar plating, and dorsal and volar plating. Cluster analysis showed that plaster fixation is associated with the lowest probability of postoperative complication in DRF patients. Plaster fixation is associated with the lowest risk for postoperative complications in DRF patients, when compared to six other common DRF surgical methods examined. PMID:26549312
Dynamic Forest: An Efficient Index Structure for NAND Flash Memory
NASA Astrophysics Data System (ADS)
Yang, Chul-Woong; Yong Lee, Ki; Ho Kim, Myoung; Lee, Yoon-Joon
In this paper, we present an efficient index structure for NAND flash memory, called the Dynamic Forest (D-Forest). Since write operations incur high overhead on NAND flash memory, D-Forest is designed to minimize write operations for index updates. The experimental results show that D-Forest significantly reduces write operations compared to the conventional B+-tree.
Shiravi, Zeinab; Shadmehr, Azadeh; Moghadam, Saeed Talebian; Moghadam, Behrouz Attarbashi
2017-01-01
Many ankle injuries occur while participating in sports that require jumping and landing such as basketball, volleyball and soccer. Most recent studies have investigated dynamic postural stability of patients with chronic ankle instability after landing from a forward jump. The present study aimed to investigate the dynamic postural stability of the athletes who suffer from chronic ankle sprain while landing from a lateral jump. Twelve athletes with self-reported unilateral chronic ankle instability (4 females and 8 males) and 12 matched controls (3 females and 9 males) voluntarily participated in the study. Dynamic postural stability index and its directional indices were measured while performing lateral jump landing test. No differences were found between athletes with and without chronic ankle instability during our landing protocol by means of the dynamic postural stability index and its directional indices. Findings showed that in each group, medial/lateral stability index is significantly higher than anterior/posterior and vertical stability indexes. Findings showed that dynamic postural stability was not significantly different between the two groups. Future studies should examine chronic ankle instability patients with more severe disabilities and expose them to more challenging dynamic balance conditions to further explore postural stability. IIIa.
Mcdonald, E; Theologis, A A; Horst, P; Kandemir, U; Pekmezci, M
2015-12-01
This study aimed at evaluating the additional stability that is provided by anterior external and internal fixators in an unstable pelvic fracture model (OTA 61-C). An unstable pelvic fracture (OTA 61-C) was created in 27 synthetic pelves by making a 5-mm gap through the sacral foramina (posterior injury) and an ipsilateral pubic rami fracture (anterior injury). The posterior injury was fixed with either a single iliosacral (IS) screw, a single trans-iliac, trans-sacral (TS) screw, or two iliosacral screws (S1S2). Two anterior fixation techniques were utilized: external fixation (Ex-Fix) and supra-acetabular external fixation and internal fixation (In-Fix); supra-acetabular pedicle screws connected with a single subcutaneous spinal rod. The specimens were tested using a nondestructive single-leg stance model. Peak-to-peak (P2P) displacement and rotation and conditioning displacement (CD) were calculated. The Ex-Fix group failed in 83.3 % of specimens with concomitant single-level posterior fixation (Total: 15/18-7 of 9 IS fixation, 8 of 9 TS fixation), and 0 % (0/9) of specimens with concomitant two-level (S1S2) posterior fixation. All specimens with the In-Fix survived testing except for two specimens treated with In-Fix combined with IS fixation. Trans-sacral fixation had higher pubic rotation and greater sacral and pubic displacement than S1S2 (p < 0.05). Rotation of the pubis and sacrum was not different between In-Fix constructs combined with single-level IS and TS fixation. In this model of an unstable pelvic fracture (OTA 61-C), anterior fixation with an In-Fix was biomechanically superior to an anterior Ex-Fix in the setting of single-level posterior fixation. There was no biomechanical difference between the In-Fix and Ex-Fix when each was combined with two levels of posterior sacral fixation.
Comparison of stability of different types of external fixation.
Grubor, Predrag; Grubor, Milan; Asotic, Mithat
2011-01-01
Stabilization of fractures by external fixator is based on the mechanical connecting of the pins, screwed into the proximal and distal bone fragment. Site of fracture is left without any foreign materials, which is essential for prevention of infections. Aim of this work is to compare stability of constructs bone model-external fixators of different types (Ortofix, Mitković, Charneley and Ilizarov). Stability is estimated under compression and bending (vertical and horizontal forces of 100 kg magnitudes, with distances between pins of4 cm). The mathematical-computer software (Tower, Planet and Planet Pro) was used in the laboratory for accurate measurements of MDP "Jelsingrad" company, Banjaluka. Interfragmental motions in millimeters at the appliance of vertical and horizontal forces were 2.80/2.56 at Ortofix (uniplanar fixator), 1.57/1.56 and fixator by Mitković-M20 (uniplanar fixator with convergent oriented pins), 0.16/0.28 at Charnely's external fixator (biplanar fixator), and 4.49/0.114 mm at Ilizarov's external fixator (fixator with two proximal and two distal rings, each attached on the 6 Kirschner wires). It has confirmed that uniplanar fixation is easier and provides sufficient biomechanics circumstances in the site of fracture for bone healing, especially if the pins are oriented convergently. Ilizarov's fixator is multiplanar fixator, but its stability is dependent of tightness of wires, and provides adequate stability only in transversal plane. By other words, each fixator has its indications; selection of the fixator should be based on theirs mechanic characteristics, fracture geometry, and potential of bone healing, with permanent simplification of treatment, which has to be safe and acceptable for the patient. The main advantage of this study is Sits nature-the comparison of four most used external fixators, by the only one possible way-on the bone model. Each other way of comparison would result with much more questions than answers, due to unacceptable high bias of other parameters, which significantly influences on the results of the study.
Ocular Fixation Abnormality in Patients with Autism Spectrum Disorder
ERIC Educational Resources Information Center
Shirama, Aya; Kanai, Chieko; Kato, Nobumasa; Kashino, Makio
2016-01-01
We examined the factors that influence ocular fixation control in adults with autism spectrum disorder (ASD) including sensory information, individuals' motor characteristics, and inhibitory control. The ASD group showed difficulty in maintaining fixation especially when there was no fixation target. The fixational eye movement characteristics of…
NASA Astrophysics Data System (ADS)
Van Wambeke, France; Gimenez, Audrey; Duhamel, Solange; Dupouy, Cécile; Lefevre, Dominique; Pujo-Pay, Mireille; Moutin, Thierry
2018-05-01
Heterotrophic prokaryotic production (BP) was studied in the western tropical South Pacific (WTSP) using the leucine technique, revealing spatial and temporal variability within the region. Integrated over the euphotic zone, BP ranged from 58 to 120 mg C m-2 d-1 within the Melanesian Archipelago, and from 31 to 50 mg C m-2 d-1 within the western subtropical gyre. The collapse of a bloom was followed during 6 days in the south of Vanuatu using a Lagrangian sampling strategy. During this period, rapid evolution was observed in the three main parameters influencing the metabolic state: BP, primary production (PP) and bacterial growth efficiency. With N2 fixation being one of the most important fluxes fueling new production, we explored relationships between BP, PP and N2 fixation rates over the WTSP. The contribution of N2 fixation rates to bacterial nitrogen demand ranged from 3 to 81 %. BP variability was better explained by the variability of N2 fixation rates than by that of PP in surface waters of the Melanesian Archipelago, which were characterized by N-depleted layers and low DIP turnover times (TDIP < 100 h). This is consistent with the fact that nitrogen was often one of the main factors controlling BP on short timescales, as shown using enrichment experiments, followed by dissolved inorganic phosphate (DIP) near the surface and labile organic carbon deeper in the euphotic zone. However, BP was more significantly correlated with PP, but not with N2 fixation rates where DIP was more available (TDIP > 100 h), deeper in the Melanesian Archipelago, or within the entire euphotic zone in the subtropical gyre. The bacterial carbon demand to gross primary production ratio ranged from 0.75 to 3.1. These values are discussed in the framework of various assumptions and conversion factors used to estimate this ratio, including the methodological errors, the daily variability of BP, the bacterial growth efficiency and one bias so far not considered: the ability for Prochlorococcus to assimilate leucine in the dark.
Ivanov, Iliya V; Mackeben, Manfred; Vollmer, Annika; Martus, Peter; Nguyen, Nhung X; Trauzettel-Klosinski, Susanne
2016-01-01
Degenerative retinal diseases, especially retinitis pigmentosa (RP), lead to severe peripheral visual field loss (tunnel vision), which impairs mobility. The lack of peripheral information leads to fewer horizontal eye movements and, thus, diminished scanning in RP patients in a natural environment walking task. This randomized controlled study aimed to improve mobility and the dynamic visual field by applying a compensatory Exploratory Saccadic Training (EST). Oculomotor responses during walking and avoiding obstacles in a controlled environment were studied before and after saccade or reading training in 25 RP patients. Eye movements were recorded using a mobile infrared eye tracker (Tobii glasses) that measured a range of spatial and temporal variables. Patients were randomly assigned to two training conditions: Saccade (experimental) and reading (control) training. All subjects who first performed reading training underwent experimental training later (waiting list control group). To assess the effect of training on subjects, we measured performance in the training task and the following outcome variables related to daily life: Response Time (RT) during exploratory saccade training, Percent Preferred Walking Speed (PPWS), the number of collisions with obstacles, eye position variability, fixation duration, and the total number of fixations including the ones in the subjects' blind area of the visual field. In the saccade training group, RTs on average decreased, while the PPWS significantly increased. The improvement persisted, as tested 6 weeks after the end of the training. On average, the eye movement range of RP patients before and after training was similar to that of healthy observers. In both, the experimental and reading training groups, we found many fixations outside the subjects' seeing visual field before and after training. The average fixation duration was significantly shorter after the training, but only in the experimental training condition. We conclude that the exploratory saccade training was beneficial for RP patients and resulted in shorter fixation durations after the training. We also found a significant improvement in relative walking speed during navigation in a real-world like controlled environment.
Ivanov, Iliya V.; Mackeben, Manfred; Vollmer, Annika; Martus, Peter; Nguyen, Nhung X.; Trauzettel-Klosinski, Susanne
2016-01-01
Purpose Degenerative retinal diseases, especially retinitis pigmentosa (RP), lead to severe peripheral visual field loss (tunnel vision), which impairs mobility. The lack of peripheral information leads to fewer horizontal eye movements and, thus, diminished scanning in RP patients in a natural environment walking task. This randomized controlled study aimed to improve mobility and the dynamic visual field by applying a compensatory Exploratory Saccadic Training (EST). Methods Oculomotor responses during walking and avoiding obstacles in a controlled environment were studied before and after saccade or reading training in 25 RP patients. Eye movements were recorded using a mobile infrared eye tracker (Tobii glasses) that measured a range of spatial and temporal variables. Patients were randomly assigned to two training conditions: Saccade (experimental) and reading (control) training. All subjects who first performed reading training underwent experimental training later (waiting list control group). To assess the effect of training on subjects, we measured performance in the training task and the following outcome variables related to daily life: Response Time (RT) during exploratory saccade training, Percent Preferred Walking Speed (PPWS), the number of collisions with obstacles, eye position variability, fixation duration, and the total number of fixations including the ones in the subjects' blind area of the visual field. Results In the saccade training group, RTs on average decreased, while the PPWS significantly increased. The improvement persisted, as tested 6 weeks after the end of the training. On average, the eye movement range of RP patients before and after training was similar to that of healthy observers. In both, the experimental and reading training groups, we found many fixations outside the subjects' seeing visual field before and after training. The average fixation duration was significantly shorter after the training, but only in the experimental training condition. Conclusions We conclude that the exploratory saccade training was beneficial for RP patients and resulted in shorter fixation durations after the training. We also found a significant improvement in relative walking speed during navigation in a real-world like controlled environment. PMID:27351629
Microbial Response to UV Exposure and Nitrogen Limitation in Desert Soil Crusts
NASA Astrophysics Data System (ADS)
Fulton, J. M.; Van Mooy, B. A.
2016-12-01
Microbiotic soil crusts have diverse biomarker distributions and C and N stable isotopic compositions that covary with soil type. Sparse plant cover and the relative lack of soil disturbance in arid/semi-arid landscapes allows populations of soil cyanobacteria to develop along with fungi and heterotrophic bacteria. Microbial communities in this extreme environment depend in part on the production of scytonemin, a UV protective pigment, by cyanobacteria near the top of the crust. N limitation of microbial growth also affects soil crust population dynamics, increasing the requirement of N2fixation by diazotrophic cyanobacteria. We collected 56 soil crust samples from 27 locations throughout the Great Salt Lake Desert, including four transects spanning high-elevation, erosion-dominated soils to lower elevation soils dominated by silt-accumulation. Erosion-dominated soil surfaces included rounded gravel and cobbles; in the interstices there were poorly-developed microbiotic crusts on sandy loam with low δ15N values near 0‰ that point toward microbial growth dependent on cyanobacterial N2 fixation. Nutrients regenerated by heterotrophic bacteria may have been eroded from the system, providing a positive feedback for N2 fixation. High scytonemin:chlorophyll a ratios suggest that cyanobacteria required enhanced protection from UV damage in these crusts. A similar increase in scytonemin:chlorophyll a ratio during soil crust rehydration experiments also points toward the importance of UV protection. Glycolipid:phospholipid ratios were lowest where N2 fixation was favored, however, suggesting that the cyanobacterial population was relatively small, possibly because of the metabolic cost of N2fixation. Microbiotic crusts on silt loam soils, on the other hand, had higher δ15N values between 3.5 and 7.8‰, consistent with heterotrophic growth and nutrient recycling. Lower scytonemin:chlorophyll a ratios suggest that relatively high photosynthetic activity was supported in these well-developed crusts. Vertical migration may have reduced the scytonemin requirement of cyanobacteria. Higher glycolipid:phospholipid ratios suggest that cyanobacteria and algae had greater relative abundance than heterotrophic bacteria in well-developed compared with erosion-dominated crusts.
Dron, Anthony; Rabouille, Sophie; Claquin, Pascal; Le Roy, Bertrand; Talec, Amélie; Sciandra, Antoine
2012-04-01
This study provides with original data sets on the physiology of the unicellular diazotrophic cyanobacterium Crocosphaera watsonii WH8501, maintained in continuous culture in conditions of obligate diazotrophy. Cultures were exposed to a 12:12 light-dark regime, representative of what they experience in nature and where growth is expected to be balanced. Nitrogen and carbon metabolism were monitored at high frequency and their dynamics was compared with the cell cycle. Results reveal a daily cycle in the physiological and biochemical parameters, tightly constrained by the timely decoupled processes of N(2) fixation and carbon acquisition. The cell division rate increased concomitantly to carbon accumulation and peaked 6 h into the light. The carbon content reached a maximum at the end of the light phase. N(2) fixation occurred mostly during the dark period and peaked between 9 and 10 h into the night, while DNA synthesis, reflected by DNA fluorescence, increased until the end of the night. Consequently, cells in G1- and S-phases present a marked decrease in their C:N ratio. Nitrogen acquisition through N(2) fixation exceeded 1.3- to 3-fold the nitrogen requirements for growth, suggesting that important amounts of nitrogen are excreted even under conditions supposed to favour balanced, carbon and nitrogen acquisitions. © 2011 Society for Applied Microbiology and Blackwell Publishing Ltd.
NASA Astrophysics Data System (ADS)
Dempster, W.; Nelson, M.; Silverstone, S.; Allen, J.; Alling, A.; van Thillo, M.
A mixed crop consisting of cowpeas pinto beans and Apogee ultra-dwarf wheat was grown in Laboratory Biosphere a 40 m 3 closed life system equipped with 12000 watts of high pressure sodium lamps over planting beds with 5 37 m 2 of soil Similar to earlier reported experiments the concentration of carbon dioxide initially increased to 7860 ppm at 10 days after planting due to soil respiration plus CO 2 contributed from researchers breathing while in the chamber for brief periods before plant growth became substantial fell rapidly as plant growth increased up to 29 days after planting and then was maintained mostly in the range of about 200 -- 3000 ppm with a few excursions by CO 2 injections to feed plant growth Numerous analyses of rate of change of CO 2 concentration at many different concentrations and at many different days after planting reveals a strong dependence of fixation rates on CO 2 concentration In the middle period of growth days 31 -- 61 fixation rates doubled for CO 2 at 450 ppm compared to 270 ppm doubled again at 1000 ppm and increased a further 50 at 2040 ppm High productivity from these crops and the increase of fixation rates with elevated CO 2 concentration supports the concept that enhanced CO2 can be a useful strategy for remote life support systems
Lee, Kwang Won; Kim, Kap Jung; Kim, Yong In; Kwon, Won Cho; Choy, Won Sik
2009-01-01
The aim of this prospective study was to assess the clinical outcomes of an unstable fracture of the lateral end of the clavicle treated with an arthroscopic-assisted locking compressive plate (LCP) clavicular hook plate. Twenty-three patients underwent arthroscopic assisted LCP clavicular hook plate fixation for these fractures. All patients achieved clinical and radiological union over a mean of 4.2 months (range, 3.4–5 months). Four patients (17%) showed some degree of acromial osteolysis. Three patients (13%) showed radiological signs of arthrosis of the acromioclavicular joint. In one patient, a second fracture (stress) was observed between the medial two screws of the plate without an additional injury. Five patients (22%) showed subacromial bursitis on dynamic ultrasonography. The mean Constant and Murley score was 91 points (range, 81–98). The average level of pain in the shoulder at rest and on abduction was 1 (range, 0–2) and 2.4 (range, 0–4), respectively. Based on our experience, arthroscopic-assisted LCP hook plate fixation for the treatment of unstable fractures of the lateral end of the clavicle is not without complications. However, it is an acceptable alternative method that is easy to apply with good results. Furthermore, it prevents rotator cuff impingement, allows early mobilisation and maintains the acromioclavicular joint biomechanics. PMID:19998033
Design-Optimization and Material Selection for a Proximal Radius Fracture-Fixation Implant
NASA Astrophysics Data System (ADS)
Grujicic, M.; Xie, X.; Arakere, G.; Grujicic, A.; Wagner, D. W.; Vallejo, A.
2010-11-01
The problem of optimal size, shape, and placement of a proximal radius-fracture fixation-plate is addressed computationally using a combined finite-element/design-optimization procedure. To expand the set of physiological loading conditions experienced by the implant during normal everyday activities of the patient, beyond those typically covered by the pre-clinical implant-evaluation testing procedures, the case of a wheel-chair push exertion is considered. Toward that end, a musculoskeletal multi-body inverse-dynamics analysis is carried out of a human propelling a wheelchair. The results obtained are used as input to a finite-element structural analysis for evaluation of the maximum stress and fatigue life of the parametrically defined implant design. While optimizing the design of the radius-fracture fixation-plate, realistic functional requirements pertaining to the attainment of the required level of the devise safety factor and longevity/lifecycle were considered. It is argued that the type of analyses employed in the present work should be: (a) used to complement the standard experimental pre-clinical implant-evaluation tests (the tests which normally include a limited number of daily-living physiological loading conditions and which rely on single pass/fail outcomes/decisions with respect to a set of lower-bound implant-performance criteria) and (b) integrated early in the implant design and material/manufacturing-route selection process.
Wrist Arthrodesis for Failed Total Wrist Arthroplasty.
Adams, Brian D; Kleinhenz, Ben P; Guan, Justin J
2016-06-01
Treatment options for failed total wrist arthroplasty include implant revision, resection arthroplasty, and arthrodesis. Variable results associated with different techniques have been reported for arthrodesis and the procedure has substantial technical challenges, including restoration of wrist height, obtaining stable fixation, and achieving bony fusion. This study evaluates the radiographic results of a surgical technique for conversion of a failed arthroplasty to an arthrodesis. A retrospective chart and radiograph review was performed in 20 wrists in 18 patients in whom conversion to an arthrodesis was performed using a contoured cancellous femoral head structural allograft and a wrist arthrodesis plate. Supplemental demineralized bone matrix combined with corticocancellous allograft chips was also used in 15 wrists. Median age at arthrodesis was 61 years (range, 45-78 years), and median follow-up was 34 months (range, 4-71 months). Nineteen of 20 wrists fused following the index procedure at a median of 4 months (range, 3-7 months). Proximal plate loosening occurred in 1 wrist but the joint still fused at 6 months; a successful osteotomy and revision of screw fixation was done 2 years later to correct the deformity and hardware irritation in this case. Complications were otherwise limited to 1 superficial infection that resolved with intravenous antibiotics. This technique for conversion of a failed total wrist arthroplasty to a wrist arthrodesis is safe, effective, and versatile. Wrist deformity is corrected, wrist height can be restored, stable fixation is obtained, and a high rate of fusion is achieved despite filling large defects using structural cancellous allograft. Therapeutic IV. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Hot topics and controversies in arthroplasty: cementless femoral fixation in elderly patients.
Dutton, Andrew; Rubash, Harry E
2008-01-01
Cementless femoral fixation has been established as the gold standard for hip arthroplasty in young patients because of its exceptional longevity. Because older Americans are living longer and staying active, cementless femoral fixation for hip arthroplasty should be considered in all patients who have good bone quality. Numerous studies have shown excellent results using cementless fixation for hip arthroplasty in elderly patients. Histologic analysis, radiographic review, and dual-energy x-ray absorptiometry have shown solid osseointegration for biologic fixation and minimal bone loss. Cementless fixation provides superb functional outcomes with results comparable to those achieved using cemented fixation for hip arthroplasty. Additional advantages of cementless femoral fixation include shorter surgical times and substantial savings in health care costs.
Fixation Characteristics of Severe Amblyopia Subtypes: Which One is Worse?
Koylu, Mehmet Talay; Ozge, Gokhan; Kucukevcilioglu, Murat; Mutlu, Fatih Mehmet; Ceylan, Osman Melih; Akıncıoglu, Dorukcan; Ayyıldız, Onder
2017-01-01
To determine differences in macular sensitivity and fixation patterns in different subtypes of severe amblyopia. This case-control study enrolled a total of 73 male adults, including 18 with pure strabismic severe amblyopia, 19 with pure anisometropic severe amblyopia, 18 with mixed (strabismic plus anizometropic) severe amblyopia, and 18 healthy controls. MP-1 microperimetry was used to evaluate macular sensitivity, location of fixation, and stability of fixation. Mean macular sensitivity, stability of fixation, and location of fixation were significantly worse in all amblyopia subtypes when compared with healthy controls. Intergroup comparisons between amblyopia subtypes revealed that mean macular sensitivity, stability of fixation, and location of fixation were significantly worse in pure strabismic and mixed amblyopic eyes when compared with pure anisometropic amblyopic eyes. Strabismus seems to be a worse prognostic factor in severe amblyopia than anisometropia in terms of fixation characteristics and retinal sensitivity.
An oculomotor continuum from exploration to fixation
Otero-Millan, Jorge; Macknik, Stephen L.; Langston, Rachel E.; Martinez-Conde, Susana
2013-01-01
During visual exploration, saccadic eye movements scan the scene for objects of interest. During attempted fixation, the eyes are relatively still but often produce microsaccades. Saccadic rates during exploration are higher than those of microsaccades during fixation, reinforcing the classic view that exploration and fixation are two distinct oculomotor behaviors. An alternative model is that fixation and exploration are not dichotomous, but are instead two extremes of a functional continuum. Here, we measured the eye movements of human observers as they either fixed their gaze on a small spot or scanned natural scenes of varying sizes. As scene size diminished, so did saccade rates, until they were continuous with microsaccadic rates during fixation. Other saccadic properties varied as function of image size as well, forming a continuum with microsaccadic parameters during fixation. This saccadic continuum extended to nonrestrictive, ecological viewing conditions that allowed all types of saccades and fixation positions. Eye movement simulations moreover showed that a single model of oculomotor behavior can explain the saccadic continuum from exploration to fixation, for images of all sizes. These findings challenge the view that exploration and fixation are dichotomous, suggesting instead that visual fixation is functionally equivalent to visual exploration on a spatially focused scale. PMID:23533278
Han, L R; Jin, C X; Yan, J; Han, S Z; He, X B; Yang, X F
2015-03-31
This study compared the efficacy between external fixator combined with palmar T-plate internal fixation and simple plate internal fixation for the treatment of comminuted distal radius fractures. A total of 61 patients classified as type C according to the AO/ASIF classification underwent surgery for comminuted distal radius fractures. There were 54 and 7 cases of closed and open fractures, respectively. Moreover, 19 patients received an external fixator combined with T-plate internal fixation, and 42 received simple plate internal fixation. All patients were treated successfully during 12-month postoperative follow-up. The follow-up results show that the palmar flexion and dorsiflexion of the wrist, radial height, and palmar angle were significantly better in those treated with the external fixator combined with T-plate compared to those treated with the simple plate only (P < 0.05); however, there were no significant differences in radial-ulnar deviation, wrist range of motion, or wrist function score between groups (P > 0.05). Hence, the effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures was satisfactory. Patients sufficiently recovered wrist, forearm, and hand function. In conclusion, compared to the simple T-plate, the external fixator combined with T-plate internal fixation can reduce the possibility of the postoperative re-shifting of broken bones and keep the distraction of fractures to maintain radial height and prevent radial shortening.
Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L
2016-12-20
Objective: To make a systematic assessment of the complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Method: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed.The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected.The included trials were screened out strictly based on the criterion of inclusion and exclusion.The quality of included trials was evaluated.RevMan 5.0 was used for data analysis. Result: A total of 17 studies involving 1 402 patients were included.There were 687 patients with open reduction and internal fixation and 715 with external fixation.The results of Meta-analysis indicated that there were statistically significant differences with regard to the postoperatively total complications, infection, malunion, tendon rupture ( I 2 =8%, RR =0.77(95% CI 0.65-0.91, Z =3.10, P <0.05). There were no statistically significant differences observed between two approaches with respect to nounion, re-operation, complex regional pain syndrome, carpal tunnel syndrome, neurapraxia, tendonitis, painful hardware, scar( P >0.05). Conclusion: Postoperative complications are present in both open reduction and internal fixation and external fixation.Compared with external fixation, open reduction and internal fixation is lower in total complications postoperatively, infection and malunion, but external fixation has lower tendon rupture incidence.
Mair, Jacqueline J; Belkoff, Stephen M; Boudrieau, Randy J
2003-01-01
To compare single versus double semitubular plate fixation for scapular body fractures. Ex vivo mechanical study. Eighteen paired cadaveric canine scapulae. Transverse scapular body osteotomies were created in the distal third of 18 pairs of scapulae. One scapula of each pair was repaired with a single plate, whereas the contralateral scapula was repaired with 2 plates. Initial strength and stiffness of the constructs were measured in 10 pairs of scapulae. Eight pairs of scapulae underwent cyclic loading and then were subjected to failure testing. Double-plate fixation was significantly stronger (3,899 +/- 632 N) but not stiffer (614 +/- 130 N/mm) than the single-plate fixation (3,238 +/- 935 N and 537 +/- 202 N/mm, respectively). Cyclic loading variables were not significantly different between the 2 methods of fixation. After cyclic loading, double-plate fixation was significantly stronger (2,916 +/- 618 N) than single-plate fixation (2,347 +/- 495 N). There was no significant difference (P =.11) in stiffness between double- versus single-plate fixations: 734 +/- 247 N/mm and 595 +/- 139 N/mm, respectively. Double-plate fixation was generally stronger and stiffer than single-plate fixation. Because all constructs failed at loads that greatly exceeded those estimated to occur clinically, any difference between the 2 methods of fixation probably is not clinically relevant. Single-plate fixation may be of sufficient strength for fixation of scapular body fractures. Copyright 2003 by The American College of Veterinary Surgeons
Screw fixation versus arthroplasty versus plate fixation for 3-part radial head fractures.
Wu, P H; Shen, L; Chee, Y H
2016-04-01
To compare the outcome following headless compression screw fixation versus radial head arthroplasty versus plate fixation for 3-part Mason types III or IV radial head fracture. Records of 25 men and 16 women aged 21 to 80 (mean, 43.3) years who underwent fixation using 2 to 3 2-mm cannulated headless compression screws (n=16), radial head arthroplasty (n=13), or fixation with a 2-mm Synthes plate (n=12) for 3-part Mason types III or IV radial head and neck fracture were reviewed. Treatment option was decided by the surgeon based on the presence of associated injury, neurovascular deficit, and the Mason classification. Bone union, callus formation, and complications (such as heterotopic ossification, malunion, and nonunion) were assessed by an independent registrar or consultant using radiographs. The Mayo Elbow Performance Score and range of motion were assessed by an independent physiotherapist. The median age of the 3 groups were comparable. Associated injuries were most common in patients with arthroplasty, followed by screw fixation and plate fixation (61.5% vs. 50% vs. 33%, p=0.54). The median time to bone union was shorter after screw fixation than plate fixation (55 vs. 86 days, p=0.05). No patient with screw fixation had nonunion, but 4 patients with plate fixation had nonunion. The 3 groups were comparable in terms of the mean Mayo Elbow Performance Score (p=0.56) and the mean range of motion (p=0.45). The complication rate was highest after plate fixation, followed by screw fixation and arthroplasty (50% vs. 18.8% vs. 15.4%, p=0.048). Excluding 20 patients with associated injuries (8 in screw fixation, 8 in arthroplasty, and 4 in plate fixation), the 3 groups were comparable in terms of the median time to bone union (p=0.109), mean Mayo Elbow Performance Score (p=0.260), mean range of motion (p=0.162), and complication rate (p=0.096). Headless compression screw fixation is a viable option for 3-part radial head fracture. It achieves earlier bone union with fewer complications.
Bachmaier, Samuel; Smith, Patrick A; Bley, Jordan; Wijdicks, Coen A
2018-02-01
To compare the dynamic elongation, stiffness behavior, and ultimate failure load of standard with small diameter soft tissue grafts for anterior cruciate ligament (ACL) reconstruction with and without high-strength suture tape reinforcement. Both a tripled "small" diameter and a "standard" quadrupled tendon graft with and without suture tape reinforcement were tested using suspensory fixation (n = 8 each group). The suture tape was passed through the suspensory fixation button on the femur and tibia to ensure independent (safety belt) fixation from the graft in vitro. The testing of the constructs included position-controlled cyclic loading, force-controlled cyclic loading at 250 N and 400 N as well as pull to failure (50 mm/min). Reinforcement of a small diameter graft significantly reduced dynamic elongation of 38% (1.46 ± 0.28 mm vs 2.34 ± 0.44 mm, P < .001) and 50% (2.55 ± 0.44 mm vs 5.06 ± 0.67 mm, P < .001) after the 250 N and 400 N load protocol, respectively. Reinforcement of a standard diameter tendon graft decreased dynamic elongation of 15% (1.59 ± 0.34 mm vs 1.86 ± 0.17 mm, P = .066) and 26% (2.62 ± 0.44 mm vs 3.55 ± 0.44 mm, P < .001). No significant difference was found between both reinforced models. The ultimate failure loads of small and standard diameter reinforced grafts were 1592 ± 105 N and 1585 ± 265 N, resulting in a 64% (P < .001) and 40% (P < .001) increase compared with their respective controls. Independent suture tape reinforcement of soft tissue grafts for ACL reconstruction leads to significantly reduced elongation and higher ultimate failure load according to in vivo native ACL function data without stress-shielding the soft tissue graft. If in vitro results are translational to human knees in vivo, the suture tape reinforcement technique for ACL reconstruction may decrease the risk of graft tears, particularly in the case of small diameter soft tissue grafts. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Different Surgical Approaches for Multiple Fractured Atrophic Mandibles
Pereira, Felipe Ladeira; Gealh, Walter Cristiano; Barbosa, Carlos Eduardo Braga; Filho, Liogi Iwaki
2011-01-01
Atrophic edentulous mandible fractures in geriatric patients have low incidence but present several biological and biomechanical peculiarities that produce a nonunion rate of around 20%. Surgical extraoral approaches for internal fixation of these fractures can be transcervical or by one or two submandibular incisions. Two patients sustaining multiple fractures in atrophic edentulous mandible are presented: the first patient was 72-years-old, treated by two submandibular incisions, and the second was 81-years-old, treated by transcervical approach. We discuss the advantages and drawbacks of each approach and their indications according to the Luhr et al (1996) atrophy index. PMID:22379503
Hao, Yinglu; Li, Yanping; Liao, Derong; Yang, Ling; Liu, Fangyan
2017-03-01
Data comparing active atrial lead fixation with passive atrial lead fixation in Chinese patients with cardiovascular implantable electronic devices (CIEDs) for atrial pacing is limited. Our study evaluated the effectiveness of active fixation versus passive fixation of atrial leads by observing the lead performance parameters. This retrospective, long-term, single-center study included a cohort of Chinese patients who underwent CIED implantation at the Department of Cardiology of People's Hospital of Yuxi City, China, from 1 March 2010 to 1 March 2015. Efficacy was determined by comparing implantation time, threshold values, incidence of lead dislocation/failure, and lead-related complications between the two groups. Of the 1217 patients, active and passive atrial lead fixation were performed in 530 (mean age, 69.37 ± 11.44 years) and 497 (mean age, 68.33 ± 10.96 years). The active fixation group reported significantly lower mean atrial implantation times (P = .0001) and threshold values (P = .044) compared with the passive atrial lead fixation group. In addition, threshold values in the active atrial lead fixation group were stable throughout the observation period. No instances of myocardial perforation, cardiac tamponade, implantation failure, or electrode dislocation/re-fixation were reported in the active atrial lead fixation group. A favorable decrease in patient comfort parameters such as bed rest time (P = .027) and duration of hospital stay (P = .038) were also observed in the active lead fixation group. Active atrial lead fixation demonstrated greater stability, steady long-term thresholds and minimal lead-related complications compared to passive lead fixation in Chinese patients with CIEDs.
Theelen, A; Martens, J; Bosmans, G; Houben, R; Jager, J J; Rutten, I; Lambin, P; Minken, A W; Baumert, B G
2012-01-01
The goal was to provide a quantitative evaluation of the accuracy of three different fixation systems for stereotactic radiotherapy and to evaluate patients' acceptance for all fixations. A total of 16 consecutive patients with brain tumours undergoing fractionated stereotactic radiotherapy (SCRT) were enrolled after informed consent (Clinical trials.gov: NCT00181350). Fixation systems evaluated were the BrainLAB® mask, with and without custom made bite-block (fixations S and A) and a homemade neck support with bite-block (fixation B) based on the BrainLAB® frame. The sequence of measurements was evaluated in a randomized manner with a cross-over design and patients' acceptance by a questionnaire. The mean three-dimensional (3D) displacement and standard deviations were 1.16 ± 0.68 mm for fixation S, 1.92 ± 1.28 and 1.70 ± 0.83 mm for fixations A and B, respectively. There was a significant improvement of the overall alignment (3D vector) when using the standard fixation instead of fixation A or B in the craniocaudal direction (p = 0.037). Rotational deviations were significantly less for the standard fixation S in relation to fixations A (p = 0.005) and B (p = 0.03). EPI imaging with off-line correction further improved reproducibility. Five out of 8 patients preferred the neck support with the bite-block. The mask fixation system in conjunction with a bite-block is the most accurate fixation for SCRT reducing craniocaudal and rotational movements. Patients favoured the more comfortable but less accurate neck support. To optimize the accuracy of SCRT, additional regular portal imaging is warranted.
Nutrient feedbacks to soil heterotrophic nitrogen fixation in forests
Perakis, Steven; Pett-Ridge, Julie C.; Catricala, Christina E.
2017-01-01
Multiple nutrient cycles regulate biological nitrogen (N) fixation in forests, yet long-term feedbacks between N-fixation and coupled element cycles remain largely unexplored. We examined soil nutrients and heterotrophic N-fixation across a gradient of 24 temperate conifer forests shaped by legacies of symbiotic N-fixing trees. We observed positive relationships among mineral soil pools of N, carbon (C), organic molybdenum (Mo), and organic phosphorus (P) across sites, evidence that legacies of symbiotic N-fixing trees can increase the abundance of multiple elements important to heterotrophic N-fixation. Soil N accumulation lowered rates of heterotrophic N-fixation in organic horizons due to both N inhibition of nitrogenase enzymes and declines in soil organic matter quality. Experimental fertilization of organic horizon soil revealed widespread Mo limitation of heterotrophic N-fixation, especially at sites where soil Mo was scarce relative to C. Fertilization also revealed widespread absence of P limitation, consistent with high soil P:Mo ratios. Responses of heterotrophic N-fixation to added Mo (positive) and N (negative) were correlated across sites, evidence that multiple nutrient controls of heterotrophic N-fixation were more common than single-nutrient effects. We propose a conceptual model where symbiotic N-fixation promotes coupled N, C, P, and Mo accumulation in soil, leading to positive feedback that relaxes nutrient limitation of overall N-fixation, though heterotrophic N-fixation is primarily suppressed by strong negative feedback from long-term soil N accumulation.
Another Approach to Measuring Human Development: The Composite Dynamic Human Development Index
ERIC Educational Resources Information Center
Bilbao-Ubillos, Javier
2013-01-01
This paper seeks mainly to contribute to the debate on how the relative degree of development of a country should be measured by proposing an indicator to build on the valuable starting point provided by the Human Development Index (HDI). The indicator proposed is called the "Composite, Dynamic Human Development Index". It incorporates in a simple…
21 CFR 888.3040 - Smooth or threaded metallic bone fixation fastener.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Smooth or threaded metallic bone fixation fastener... metallic bone fixation fastener. (a) Identification. A smooth or threaded metallic bone fixation fastener..., slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a...
21 CFR 888.3040 - Smooth or threaded metallic bone fixation fastener.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Smooth or threaded metallic bone fixation fastener... metallic bone fixation fastener. (a) Identification. A smooth or threaded metallic bone fixation fastener..., slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a...
21 CFR 888.3040 - Smooth or threaded metallic bone fixation fastener.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Smooth or threaded metallic bone fixation fastener... metallic bone fixation fastener. (a) Identification. A smooth or threaded metallic bone fixation fastener..., slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a...
21 CFR 888.3040 - Smooth or threaded metallic bone fixation fastener.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Smooth or threaded metallic bone fixation fastener... metallic bone fixation fastener. (a) Identification. A smooth or threaded metallic bone fixation fastener..., slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a...
21 CFR 888.3040 - Smooth or threaded metallic bone fixation fastener.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Smooth or threaded metallic bone fixation fastener... metallic bone fixation fastener. (a) Identification. A smooth or threaded metallic bone fixation fastener..., slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a...
NASA Astrophysics Data System (ADS)
Berthelot, H.; Benavides, M.; Moisander, P. H.; Grosso, O.; Bonnet, S.
2017-08-01
Dinitrogen (N2) fixation rates were investigated in the euphotic layer of the Bismarck and Solomon Seas using 15N2 incubation assays taking into account both the particulate and the dissolved pools. Average depth-integrated particulate N2 fixation rates were 203 (range 43-399) and 1396 (range 176-3132) μmol N m-2 d-1 in the Bismarck and Solomon Seas, respectively. In both seas, N2 fixation measured in the dissolved pool was similar to particulate N2 fixation, highlighting the potentially substantial underestimation of N2 fixation in oceanic budgets when only particulate N2 fixation is considered. Among the diazotroph phylotypes targeted using quantitative polymerase chain reaction amplification of nifH genes, Trichodesmium was the most abundant. Regression analyses suggest that it accounted for the major proportion of N2 fixation. However, unicellular cyanobacterial and non-cyanobacterial diazotrophs were also occasionally abundant. This study reports high pelagic N2 fixation rates and confirms that the Western Tropical South Pacific is a hot spot for marine N2 fixation.
Arch index and running biomechanics in children aged 10-14 years.
Hollander, Karsten; Stebbins, Julie; Albertsen, Inke Marie; Hamacher, Daniel; Babin, Kornelia; Hacke, Claudia; Zech, Astrid
2018-03-01
While altered foot arch characteristics (high or low) are frequently assumed to influence lower limb biomechanics and are suspected to be a contributing factor for injuries, the association between arch characteristics and lower limb running biomechanics in children is unclear. Therefore, the aim of this study was to investigate the relationship between a dynamically measured arch index and running biomechanics in healthy children. One hundred and one children aged 10-14 years were included in this study and underwent a biomechanical investigation. Plantar distribution (Novel, Emed) was used to determine the dynamic arch index and 3D motion capture (Vicon) to measure running biomechanics. Linear mixed models were established to determine the association between dynamic arch index and foot strike patterns, running kinematics, kinetics and temporal-spatial outcomes. No association was found between dynamic arch index and rate of rearfoot strikes (p = 0.072). Of all secondary outcomes, only the foot progression angle was associated with the dynamic arch index (p = 0.032) with greater external rotation in lower arched children. Overall, we found only few associations between arch characteristics and running biomechanics in children. However, altered foot arch characteristics are of clinical interest. Future studies should focus on detailed foot biomechanics and include clinically diagnosed high and low arched children. Copyright © 2018 Elsevier B.V. All rights reserved.
Complement fixation test to C burnetii
... complement fixation test; Coxiella burnetii - complement fixation test; C burnetii - complement fixation test ... a specific foreign substance ( antigen ), in this case, C burnetii . Antibodies defend the body against bacteria, viruses, ...
Accommodation and pupil responses to random-dot stereograms
Suryakumar, Rajaraman; Allison, Robert
2015-01-01
We investigated the dynamics of accommodative and pupillary responses to random-dot stereograms presented in crossed and uncrossed disparity in six visually normal young adult subjects (mean age = 25.8 ± 3.1 years). Accommodation and pupil measures were monitored monocularly with a custom built photorefraction system while subjects fixated at the center of a random-dot stereogram. On each trial, the stereogram initially depicted a flat plane and then changed to depict a sinusoidal corrugation in depth while fixation remained constant. Increase in disparity specified depth resulted in pupil constriction during both crossed and uncrossed disparity presentations. The change in pupil size between crossed and uncrossed disparity conditions was not significantly different (p > 0.05). The change in pupil size was also accompanied by a small concomitant increase in accommodation. In addition, the dynamic properties of pupil responses varied as a function of their initial (starting) diameter. The finding that accommodation and pupil responses increased with disparity regardless of the sign of retinal disparity suggests that these responses were driven by apparent depth rather than shifts in mean simulated distance of the stimulus. Presumably the need for the increased depth of focus when viewing stimuli extended in depth results in pupil constriction which also results in a concomitant change in accommodation. Starting position effects in pupil response confirm the non-linearity in the operating range of the pupil. PMID:25891121
The climate benefits of high-sugar grassland may be compromised by ozone pollution.
Hewitt, D K L; Mills, G; Hayes, F; Davies, W
2016-09-15
High sugar ryegrasses (HSG) have been developed to improve the uptake, digestion and nitrogen (N)-utilisation of grazing stock, with the potential to increase production yields and benefit climate by reducing methane (CH4) and nitrous oxide (N2O) emissions from livestock farming. In this study, the effects of tropospheric ozone pollution on the seasonal growth dynamics of HSG pasture mesocosms containing Lolium perenne cv. AberMagic and Trifolium repens cv. Crusader were investigated. Species-specific ozone (O3) dose-response relationships (seasonal means: 35, 41, 47, 51, 59 & 67ppb) based on the Phytotoxic Ozone Dose (PODy) were constructed for above and below ground biomass, injury, N-fixation and forage quality. The dynamics of effects of ozone exposure on HSG pasture changed over the course of a season, with the strongest responses occurring in the first 4-8weeks. Overall, strong negative responses to ozone flux were found for root biomass, root nodule mass and N-fixation rates, and ozone adversely impacted a range of forage quality parameters including total sugar content and relative and consumable food values. These results indicate that increasing ozone pollution could decrease the N-use efficiency and reduce the sugar content of managed pasture, and thereby partially detract from some of the suggested benefits of HSG. Copyright © 2016 Elsevier B.V. All rights reserved.
WKB theory of large deviations in stochastic populations
NASA Astrophysics Data System (ADS)
Assaf, Michael; Meerson, Baruch
2017-06-01
Stochasticity can play an important role in the dynamics of biologically relevant populations. These span a broad range of scales: from intra-cellular populations of molecules to population of cells and then to groups of plants, animals and people. Large deviations in stochastic population dynamics—such as those determining population extinction, fixation or switching between different states—are presently in a focus of attention of statistical physicists. We review recent progress in applying different variants of dissipative WKB approximation (after Wentzel, Kramers and Brillouin) to this class of problems. The WKB approximation allows one to evaluate the mean time and/or probability of population extinction, fixation and switches resulting from either intrinsic (demographic) noise, or a combination of the demographic noise and environmental variations, deterministic or random. We mostly cover well-mixed populations, single and multiple, but also briefly consider populations on heterogeneous networks and spatial populations. The spatial setting also allows one to study large fluctuations of the speed of biological invasions. Finally, we briefly discuss possible directions of future work.
Sunness, Janet S.; Applegate, Carol A.; Haselwood, David; Rubin, Gary S.
2009-01-01
Purpose To study fixation patterns and reading rates in eyes with central scotomas from geographic atrophy (GA) of age-related macular degeneration and to compare fixation patterns with those of patients with Stargardt disease. Methods Scanning laser ophthalmoscope analysis of fixation patterns in eyes with 20/80 to 20/200 visual acuity. Included were 41 eyes of 35 patients with GA and 10 eyes of 5 patients with Stargardt disease. The patients with GA also were tested for maximum reading rate, and the size of the areas of atrophy were measured by fundus photograph analysis. Results Sixty-three percent of GA eyes fixating outside the atrophy placed the scotoma to the right of fixation in visual field space, 22% placed the scotoma above fixation, and 15% placed it to the left, regardless of the laterality of the GA eye. Fixation was stable in subsequent years of testing for scotoma placement to the right of or above fixation. All GA eyes fixated immediately adjacent to the atrophy. In contrast, seven of ten eyes with Stargardt disease fixated at a considerable distance from the scotoma border, with the dense scotoma far above the fixation site in visual field space. For the patients with GA, the maximum reading rate was highly correlated with size of the atrophic area, but not with age or visual acuity within the limited visual acuity range tested. There was a trend to more rapid reading with the scotoma above fixation and slower reading with the scotoma to the left. Conclusion There is a preference for fixation with the scotoma to the right in eyes with GA. Patients with Stargardt disease use different strategies for fixation, perhaps due to subclinical pathology adjacent to the atrophic regions. The size of the atrophic area in GA plays the predominant role in reading rate for eyes that have already lost foveal vision. PMID:8841306
Lapsiwala, Samir B; Anderson, Paul A; Oza, Ashish; Resnick, Daniel K
2006-03-01
We performed a biomechanical comparison of several C1 to C2 fixation techniques including crossed laminar (intralaminar) screw fixation, anterior C1 to C2 transarticular screw fixation, C1 to 2 pedicle screw fixation, and posterior C1 to C2 transarticular screw fixation. Eight cadaveric cervical spines were tested intact and after dens fracture. Four different C1 to C2 screw fixation techniques were tested. Posterior transarticular and pedicle screw constructs were tested twice, once with supplemental sublaminar cables and once without cables. The specimens were tested in three modes of loading: flexion-extension, lateral bending, and axial rotation. All tests were performed in load and torque control. Pure bending moments of 2 nm were applied in flexion-extension and lateral bending, whereas a 1 nm moment was applied in axial rotation. Linear displacements were recorded from extensometers rigidly affixed to the C1 and C2 vertebrae. Linear displacements were reduced to angular displacements using trigonometry. Adding cable fixation results in a stiffer construct for posterior transarticular screws. The addition of cables did not affect the stiffness of C1 to C2 pedicle screw constructs. There were no significant differences in stiffness between anterior and posterior transarticular screw techniques, unless cable fixation was added to the posterior construct. All three posterior screw constructs with supplemental cable fixation provide equal stiffness with regard to flexion-extension and axial rotation. C1 lateral mass-C2 intralaminar screw fixation restored resistance to lateral bending but not to the same degree as the other screw fixation techniques. All four screw fixation techniques limit motion at the C1 to 2 articulation. The addition of cable fixation improves resistance to flexion and extension for posterior transarticular screw fixation.
Hsiao, Yi-Ting; Shillcock, Richard; Obregón, Mateo; Kreiner, Hamutal; Roberts, Matthew A J; McDonald, Scott
2017-07-11
We explore two aspects of exovergence: we test whether smaller binocular fixation disparities accompany the shorter saccades and longer fixations observed in reading Chinese; we test whether potentially advantageous psychophysical effects of exovergence (cf. Arnold & Schindel, 2010; Kersten & Murray, 2010) transfer to text reading. We report differential exovergence in reading Chinese and English: Chinese readers begin fixations with more binocular disparity, but end fixations with a disparity closely similar to that of the English readers. We conclude that greater fixation-initial binocular fixation disparity can be adaptive in the reading of visually and cognitively denser text.
Ueda, Hiroshi; Takahashi, Kohske; Watanabe, Katsumi
2013-04-19
The saccadic "gap effect" refers to a phenomenon whereby saccadic reaction times (SRTs) are shortened by the removal of a visual fixation stimulus prior to target presentation. In the current study, we investigated whether the gap effect was influenced by retinal input of a fixation stimulus, as well as phenomenal permanence and/or expectation of the re-emergence of a fixation stimulus. In Experiment 1, we used an occluded fixation stimulus that was gradually hidden by a moving plate prior to the target presentation, which produced the impression that the fixation stimulus still remained and would reappear from behind the plate. We found that the gap effect was significantly weakened with the occluded fixation stimulus. However, the SRT with the occluded fixation stimulus was still shorter in comparison to when the fixation stimulus physically remained on the screen. In Experiment 2, we investigated whether this effect was due to phenomenal maintenance or expectation of the reappearance of the fixation stimulus; this was achieved by using occluding plates that were an identical color to the background screen, giving the impression of reappearance of the fixation stimulus but not of its maintenance. The result showed that the gap effect was still weakened by the same degree even without phenomenal maintenance of the fixation stimulus. These results suggest that the saccadic gap effect is modulated by both retinal input and subjective expectation of re-emergence of the fixation stimulus. In addition to oculomotor mechanisms, other components, such as attentional mechanisms, likely contribute to facilitation of the subsequent action. Copyright © 2013 Elsevier Ltd. All rights reserved.
Spatiotemporal properties of microsaccades: Model predictions and experimental tests
NASA Astrophysics Data System (ADS)
Zhou, Jian-Fang; Yuan, Wu-Jie; Zhou, Zhao
2016-10-01
Microsaccades are involuntary and very small eye movements during fixation. Recently, the microsaccade-related neural dynamics have been extensively investigated both in experiments and by constructing neural network models. Experimentally, microsaccades also exhibit many behavioral properties. It’s well known that the behavior properties imply the underlying neural dynamical mechanisms, and so are determined by neural dynamics. The behavioral properties resulted from neural responses to microsaccades, however, are not yet understood and are rarely studied theoretically. Linking neural dynamics to behavior is one of the central goals of neuroscience. In this paper, we provide behavior predictions on spatiotemporal properties of microsaccades according to microsaccade-induced neural dynamics in a cascading network model, which includes both retinal adaptation and short-term depression (STD) at thalamocortical synapses. We also successfully give experimental tests in the statistical sense. Our results provide the first behavior description of microsaccades based on neural dynamics induced by behaving activity, and so firstly link neural dynamics to behavior of microsaccades. These results indicate strongly that the cascading adaptations play an important role in the study of microsaccades. Our work may be useful for further investigations of the microsaccadic behavioral properties and of the underlying neural dynamical mechanisms responsible for the behavioral properties.
Sod, Gary A; Mitchell, Colin F; Hubert, Jeremy D; Martin, George S; Gill, Marjorie S
2007-12-01
To compare in vitro monotonic biomechanical properties of an equine spoon plate (ESP) with an axial 3-hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws (DCP-TLS) inserted in lag fashion for equine proximal interphalangeal (PIP) joint arthrodesis. Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. Cadaveric adult equine forelimbs (n=18 pairs). For each forelimb pair, 1 PIP joint was stabilized with an ESP (8 hole, 4.5 mm) and 1 with an axial 3-hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion. Six matching pairs of constructs were tested in single cycle to failure under axial compression with load applied under displacement control at a constant rate of 5 cm/s. Six construct pairs were tested for cyclic fatigue under axial compression with cyclic load (0-7.5 kN) applied at 6 Hz; cycles to failure were recorded. Six construct pairs were tested in single cycle to failure under torsional loading applied at a constant displacement rate (0.17 radians/s) until rotation of 0.87 radians occurred. Mean values for each fixation method were compared using a paired t-test within each group with statistical significance set at P<.05. Mean yield load, yield stiffness, and failure load for ESP fixation were significantly greater (for axial compression and torsion) than for DCP-TLS fixation. Mean (+/- SD) values for the ESP and DCP-TLS fixation techniques, respectively, in single cycle to failure under axial compression were: yield load 123.9 +/- 8.96 and 28.5 +/- 3.32 kN; stiffness, 13.11 +/- 0.242 and 2.60 +/- 0.17 kN/cm; and failure load, 144.4 +/- 13.6 and 31.4 +/- 3.8 kN. In single cycle to failure under torsion, mean (+/- SD) values for ESP and DCP-TLS, respectively, were: stiffness 2,022 +/- 26.2 and 107.9 +/- 11.1 N m/rad; and failure load: 256.4 +/- 39.2 and 87.1 +/- 11.5 N m. Mean cycles to failure in axial compression of ESP fixation (622,529 +/- 65,468) was significantly greater than DCP-TLS (95,418 +/- 11,037). ESP was superior to an axial 3-hole narrow DCP with 2 abaxial transarticular screws inserted in lag fashion in resisting static overload forces and cyclic fatigue. In vitro results support further evaluation of ESP for PIP joint arthrodesis in horses. Its specific design may provide increased stability without need for external coaptation support.
The Role of Personality and Team-Based Product Dissection on Fixation Effects
ERIC Educational Resources Information Center
Toh, Christine; Miller, Scarlett; Kremer, Gül E. Okudan
2013-01-01
Design fixation has been found to be complex in its definition and expression, but it plays an important role in design idea generation. Identifying the factors that influence fixation is crucial in understanding how to enhance the design process and reduce the negative effects of fixation. One way to potentially mitigate fixation is through…
OʼToole, Robert V; Gary, Joshua L; Reider, Lisa; Bosse, Michael J; Gordon, Wade T; Hutson, James; Quinnan, Stephen M; Castillo, Renan C; Scharfstein, Daniel O; MacKenzie, Ellen J
2017-04-01
The treatment of high-energy open tibia fractures is challenging in both the military and civilian environments. Treatment with modern ring external fixation may reduce complications common in these patients. However, no study has rigorously compared outcomes of modern ring external fixation with commonly used internal fixation approaches. The FIXIT study is a prospective, multicenter randomized trial comparing 1-year outcomes after treatment of severe open tibial shaft fractures with modern external ring fixation versus internal fixation among men and women of ages 18-64. The primary outcome is rehospitalization for major limb complications. Secondary outcomes include infection, fracture healing, limb function, and patient-reported outcomes including physical function and pain. One-year treatment costs and patient satisfaction will be compared between the 2 groups, and the percentage of Gustilo IIIB fractures that can be salvaged without soft tissue flap among patients receiving external fixation will be estimated.
Optofluidic refractive-index sensor in step-index fiber with parallel hollow micro-channel.
Lee, H W; Schmidt, M A; Uebel, P; Tyagi, H; Joly, N Y; Scharrer, M; Russell, P St J
2011-04-25
We present a simple refractive index sensor based on a step-index fiber with a hollow micro-channel running parallel to its core. This channel becomes waveguiding when filled with a liquid of index greater than silica, causing sharp dips to appear in the transmission spectrum at wavelengths where the glass-core mode phase-matches to a mode of the liquid-core. The sensitivity of the dip-wavelengths to changes in liquid refractive index is quantified and the results used to study the dynamic flow characteristics of fluids in narrow channels. Potential applications of this fiber microstructure include measuring the optical properties of liquids, refractive index sensing, biophotonics and studies of fluid dynamics on the nanoscale.
Qin, S H; Guo, B F; Zheng, X J; Jiao, S F; Xia, H T; Peng, A M; Pan, Q; Zang, J C; Wang, Z J
2017-09-01
Objective: To discuss the clinical application and effects of domestic external fixator in the treatment of patients with malformations of limbs. Methods: A total of 7 289 patients with malformation of limbs who had been operated in Qin Sihe orthopedic surgery team from January 1989 to June 2016 were retrospective analyzed. The patients were treated with domestic external fixator, including 4 033 males and 3 256 females, aging from 2 to 82 years with a mean age of 23.4 years. There were 2 732 patients using Ilizarov external fixator, 4 713 patients using hybrid external fixator, 57 patients using monobrachial external fixator, 232 patients using Ilizarov external fixator and hybrid external fixator. The Ilizarov, hybrid and monobrachial external fixator were used in 67, 65 and 0 patients on the upper limbs and in 2 665, 4 616 and 57 patients on the lower limbs. There were 3 028 patients operated on the left limbs, 3 260 patients operated on the right limbs and 1 001 patients operated on the bilateral limbs. The top three types of diseases were sequelae of poliomyelitis, cerebral palsy and post-traumatic stress disorder peromely. Deformity types inclued talipes equinovarus, knee flexion deformity, cavus foot and so on. Results: All the patients were followed up for a period of 2.5 months to 22.4 years, with an average follow-up time of 5.4 years. All of the external fixators were used for single once, and there was no substitute for external fixator quality problem. All the patients were completed surgery goal until removing external fixation except 1 patient gave up treatment and 1 removed the fixator because of metal allergy. The common complications included wire or pin infection and joint movement limitation and so on. Conclusions: The domestic external fixator developed and produced based on the characteristics of Chinese limb deformity disability. The domestic external fixator can be used to treat kinds of limb deformities with the advantages of practical, economical, adjustable, universal and portable. The domestic external fixator could meet the clinical demand for fixation of the osteotomy end of the limbs, the correction of the deformity, the repair of the defects and the limb lengthening.
Fixation strength analysis of cup to bone material using finite element simulation
NASA Astrophysics Data System (ADS)
Anwar, Iwan Budiwan; Saputra, Eko; Ismail, Rifky; Jamari, J.; van der Heide, Emile
2016-04-01
Fixation of acetabular cup to bone material is an important initial stability for artificial hip joint. In general, the fixation in cement less-type acetabular cup uses press-fit and screw methods. These methods can be applied alone or together. Based on literature survey, the additional screw inside of cup is effective; however, it has little effect in whole fixation. Therefore, an acetabular cup with good fixation, easy manufacture and easy installation is required. This paper is aiming at evaluating and proposing a new cup fixation design. To prove the strength of the present cup fixation design, the finite element simulation of three dimensional cup with new fixation design was performed. The present cup design was examined with twist axial and radial rotation. Results showed that the proposed cup design was better than the general version.
Formaldehyde substitute fixatives: effects on nucleic acid preservation.
Moelans, Cathy B; Oostenrijk, Daphne; Moons, Michiel J; van Diest, Paul J
2011-11-01
In surgical pathology, formalin-fixed paraffin-embedded tissues are increasingly being used as a source of DNA and RNA for molecular assays in addition to histopathological evaluation. However, the commonly used formalin fixative is carcinogenic, and its crosslinking impairs DNA and RNA quality. The suitability of three new presumably less toxic, crosslinking (F-Solv) and non-crosslinking (FineFIX, RCL2) alcohol-based fixatives was tested for routine molecular pathology in comparison with neutral buffered formalin (NBF) as gold standard. Size ladder PCR, epidermal growth factor receptor sequence analysis, microsatellite instability (MSI), chromogenic (CISH), fluorescence in situ hybridisation (FISH) and qPCR were performed. The alcohol-based non-crosslinking fixatives (FineFIX and RCL2) resulted in a higher DNA yield and quality compared with crosslinking fixatives (NBF and F-Solv). Size ladder PCR resulted in a shorter amplicon size (300 bp) for both crosslinking fixatives compared with the non-crosslinking fixatives (400 bp). All four fixatives were directly applicable for MSI and epidermal growth factor receptor sequence analysis. All fixatives except F-Solv showed clear signals in CISH and FISH. RNA yield and quality were superior after non-crosslinking fixation. qPCR resulted in lower Ct values for RCL2 and FineFIX. The alcohol-based non-crosslinking fixatives performed better than crosslinking fixatives with regard to DNA and RNA yield, quality and applicability in molecular diagnostics. Given the higher yield, less starting material may be necessary, thereby increasing the applicability of biopsies for molecular studies.
E-Index for Differentiating Complex Dynamic Traits
Qi, Jiandong; Sun, Jianfeng; Wang, Jianxin
2016-01-01
While it is a daunting challenge in current biology to understand how the underlying network of genes regulates complex dynamic traits, functional mapping, a tool for mapping quantitative trait loci (QTLs) and single nucleotide polymorphisms (SNPs), has been applied in a variety of cases to tackle this challenge. Though useful and powerful, functional mapping performs well only when one or more model parameters are clearly responsible for the developmental trajectory, typically being a logistic curve. Moreover, it does not work when the curves are more complex than that, especially when they are not monotonic. To overcome this inadaptability, we therefore propose a mathematical-biological concept and measurement, E-index (earliness-index), which cumulatively measures the earliness degree to which a variable (or a dynamic trait) increases or decreases its value. Theoretical proofs and simulation studies show that E-index is more general than functional mapping and can be applied to any complex dynamic traits, including those with logistic curves and those with nonmonotonic curves. Meanwhile, E-index vector is proposed as well to capture more subtle differences of developmental patterns. PMID:27064292
Feature integration, attention, and fixations during visual search.
Khani, Abbas; Ordikhani-Seyedlar, Mehdi
2017-01-01
We argue that mechanistic premises of "item-based" theories are not invalidated by the fixation-based approach. We use item-based theories to propose an account that does not advocate strict serial item processing and integrates fixations. The main focus of this account is feature integration within fixations. We also suggest that perceptual load determines the size of the fixations.
Modeling fixation locations using spatial point processes.
Barthelmé, Simon; Trukenbrod, Hans; Engbert, Ralf; Wichmann, Felix
2013-10-01
Whenever eye movements are measured, a central part of the analysis has to do with where subjects fixate and why they fixated where they fixated. To a first approximation, a set of fixations can be viewed as a set of points in space; this implies that fixations are spatial data and that the analysis of fixation locations can be beneficially thought of as a spatial statistics problem. We argue that thinking of fixation locations as arising from point processes is a very fruitful framework for eye-movement data, helping turn qualitative questions into quantitative ones. We provide a tutorial introduction to some of the main ideas of the field of spatial statistics, focusing especially on spatial Poisson processes. We show how point processes help relate image properties to fixation locations. In particular we show how point processes naturally express the idea that image features' predictability for fixations may vary from one image to another. We review other methods of analysis used in the literature, show how they relate to point process theory, and argue that thinking in terms of point processes substantially extends the range of analyses that can be performed and clarify their interpretation.
Distraction by a monotube fixator to achieve limb lengthening: predictive factors for tibia trauma
2013-01-01
Background Management of post trauma tibia bone gap varied with orthopedic surgeons’ experience and tools available. Study aims to determine predictive factors for distraction by a monotube fixator (DMF) outcome in post tibia trauma limb length discrepancy. Methods A prospective descriptive cross sectional study of post traumatized tibia bone gap and limb length discrepancy patients at tertiary hospitals. Patient’s informed consent and institutional ethical committee approval were obtained. Bio-data, clinical and healing indexes were documented. DMF was applied for patient that met inclusion criteria. The Statistic tests used included the Chi-square, the Student’s two-tailed t test, and the Wilcox on rank-sum test when appropriate. Mantel-Haenszel Common Odds Ratio (OR) and 95% confidence intervals for poor outcome potential risk factors were recorded. Bivariate correlation and logistic regression were evaluated. Significance level was set at a p value <0.05. Results Thirty-six patients with mean age, 37.2 ± 10.3 year and male/female ratio of 1:1.25 had DMF applied. Motorcycle accident accounted for 50.0% of patients and diaphyseal segment was most commonly affected 25 (69.4%). The mean bone lengthened was 10.1 ± 4.0 cm (range: 5-21 cm) and mean duration of bone transport was 105.6 ± 38.2 days. The means of rate of distraction, healing index and percentage of lengthening were 0.99 ± 0.14 mm/day, 15.6 ± 4.3 days/cm and 38.0 ± 14.3 respectively. The mean follow up was 9.7 ±4.9 months (range: 2–17.0). Per operative complications varied and outcome was satisfactory in 30 (83.3%). Obesity (p <0.0001), multiple surgery (p = 0.012) and transfusion (p = 0.001) correlated to poor outcome. Percentage lengthening ≥ 50%, bone gap >10 cm, anemia, blood transfusion, general anesthesia administration, distraction rate >1 mm/day, osteomyelitis and prolong partial weight bearing were significant predictive factors for poor outcome in post traumatic tibia distraction. Conclusion Distraction by a monotube fixator appears effective in achieving correction >38.0% original tibia lengthening following traumatic bone gap. Predictive factors for poor outcome were useful for prognostication. PMID:23672599
Mallery, Robert M; Poolman, Pieter; Thurtell, Matthew J; Wang, Jui-Kai; Garvin, Mona K; Ledolter, Johannes; Kardon, Randy H
2016-07-01
The purpose of this study was to assess whether clinically useful measures of fixation instability and eccentricity can be derived from retinal tracking data obtained during optical coherence tomography (OCT) in patients with optic neuropathy (ON) and to develop a method for relating fixation to the retinal ganglion cell complex (GCC) thickness. Twenty-nine patients with ON underwent macular volume OCT with 30 seconds of confocal scanning laser ophthalmoscope (cSLO)-based eye tracking during fixation. Kernel density estimation quantified fixation instability and fixation eccentricity from the distribution of fixation points on the retina. Preferred ganglion cell layer loci (PGCL) and their relationship to the GCC thickness map were derived, accounting for radial displacement of retinal ganglion cell soma from their corresponding cones. Fixation instability was increased in ON eyes (0.21 deg2) compared with normal eyes (0.06982 deg2; P < 0.001), and fixation eccentricity was increased in ON eyes (0.48°) compared with normal eyes (0.24°; P = 0.03). Fixation instability and eccentricity each correlated moderately with logMAR acuity and were highly predictive of central visual field loss. Twenty-six of 35 ON eyes had PGCL skewed toward local maxima of the GCC thickness map. Patients with bilateral dense central scotomas had PGCL in homonymous retinal locations with respect to the fovea. Fixation instability and eccentricity measures obtained during cSLO-OCT assess the function of perifoveal retinal elements and predict central visual field loss in patients with ON. A model relating fixation to the GCC thickness map offers a method to assess the structure-function relationship between fixation and areas of preserved GCC in patients with ON.
M. Mallery, Robert; Poolman, Pieter; J. Thurtell, Matthew; Wang, Jui-Kai; K. Garvin, Mona; Ledolter, Johannes; Kardon, Randy H.
2016-01-01
Purpose The purpose of this study was to assess whether clinically useful measures of fixation instability and eccentricity can be derived from retinal tracking data obtained during optical coherence tomography (OCT) in patients with optic neuropathy (ON) and to develop a method for relating fixation to the retinal ganglion cell complex (GCC) thickness. Methods Twenty-nine patients with ON underwent macular volume OCT with 30 seconds of confocal scanning laser ophthalmoscope (cSLO)-based eye tracking during fixation. Kernel density estimation quantified fixation instability and fixation eccentricity from the distribution of fixation points on the retina. Preferred ganglion cell layer loci (PGCL) and their relationship to the GCC thickness map were derived, accounting for radial displacement of retinal ganglion cell soma from their corresponding cones. Results Fixation instability was increased in ON eyes (0.21 deg2) compared with normal eyes (0.06982 deg2; P < 0.001), and fixation eccentricity was increased in ON eyes (0.48°) compared with normal eyes (0.24°; P = 0.03). Fixation instability and eccentricity each correlated moderately with logMAR acuity and were highly predictive of central visual field loss. Twenty-six of 35 ON eyes had PGCL skewed toward local maxima of the GCC thickness map. Patients with bilateral dense central scotomas had PGCL in homonymous retinal locations with respect to the fovea. Conclusions Fixation instability and eccentricity measures obtained during cSLO-OCT assess the function of perifoveal retinal elements and predict central visual field loss in patients with ON. A model relating fixation to the GCC thickness map offers a method to assess the structure–function relationship between fixation and areas of preserved GCC in patients with ON. PMID:27409502
Individual Objective and Subjective Fixation Disparity in Near Vision
Jaschinski, Wolfgang
2017-01-01
Binocular vision refers to the integration of images in the two eyes for improved visual performance and depth perception. One aspect of binocular vision is the fixation disparity, which is a suboptimal condition in individuals with respect to binocular eye movement control and subsequent neural processing. The objective fixation disparity refers to the vergence angle between the visual axes, which is measured with eye trackers. Subjective fixation disparity is tested with two monocular nonius lines which indicate the physical nonius separation required for perceived alignment. Subjective and objective fixation disparity represent the different physiological mechanisms of motor and sensory fusion, but the precise relation between these two is still unclear. This study measures both types of fixation disparity at viewing distances of 40, 30, and 24 cm while observers fixated a central stationary fusion target. 20 young adult subjects with normal binocular vision were tested repeatedly to investigate individual differences. For heterophoria and subjective fixation disparity, this study replicated that the binocular system does not properly adjust to near targets: outward (exo) deviations typically increase as the viewing distance is shortened. This exo proximity effect—however—was not found for objective fixation disparity, which–on the average–was zero. But individuals can have reliable outward (exo) or inward (eso) vergence errors. Cases with eso objective fixation disparity tend to have less exo states of subjective fixation disparity and heterophoria. In summary, the two types of fixation disparity seem to respond in a different way when the viewing distance is shortened. Motor and sensory fusion–as reflected by objective and subjective fixation disparity–exhibit complex interactions that may differ between individuals (eso versus exo) and vary with viewing distance (far versus near vision). PMID:28135308
Retrieval of canopy moisture content for dynamic fire risk assessment using simulated MODIS bands
NASA Astrophysics Data System (ADS)
Maffei, Carmine; Leone, Antonio P.; Meoli, Giuseppe; Calabrò, Gaetano; Menenti, Massimo
2007-10-01
Forest fires are one of the major environmental hazards in Mediterranean Europe. Biomass burning reduces carbon fixation in terrestrial vegetation, while soil erosion increases in burned areas. For these reasons, more sophisticated prevention tools are needed by local authorities to forecast fire danger, allowing a sound allocation of intervention resources. Various factors contribute to the quantification of fire hazard, and among them vegetation moisture is the one that dictates vegetation susceptibility to fire ignition and propagation. Many authors have demonstrated the role of remote sensing in the assessment of vegetation equivalent water thickness (EWT), which is defined as the weight of liquid water per unit of leaf surface. However, fire models rely on the fuel moisture content (FMC) as a measure of vegetation moisture. FMC is defined as the ratio of the weight of the liquid water in a leaf over the weight of dry matter, and its retrieval from remote sensing measurements might be problematic, since it is calculated from two biophysical properties that independently affect vegetation reflectance spectrum. The aim of this research is to evaluate the potential of the Moderate Resolution Imaging Spectrometer (MODIS) in retrieving both EWT and FMC from top of the canopy reflectance. The PROSPECT radiative transfer code was used to simulate leaf reflectance and transmittance as a function of leaf properties, and the SAILH model was adopted to simulate the top of the canopy reflectance. A number of moisture spectral indexes have been calculated, based on MODIS bands, and their performance in predicting EWT and FMC has been evaluated. Results showed that traditional moisture spectral indexes can accurately predict EWT but not FMC. However, it has been found that it is possible to take advantage of the multiple MODIS short-wave infrared (SWIR) channels to improve the retrieval accuracy of FMC (r2 = 0.73). The effects of canopy structural properties on MODIS estimates of FMC have been evaluated, and it has been found that the limiting factor is leaf area index (LAI). The best results are recorded for LAI>2 (r2 = 0.83), while acceptable results (r2 = 0.58) can still be achieved for lower vegetation cover density.
NASA Astrophysics Data System (ADS)
Koenrades, Maaike A.; Struijs, Ella M.; Klein, Almar; Kuipers, Henny; Geelkerken, Robert H.; Slump, Cornelis H.
2017-03-01
The application of endovascular aortic aneurysm repair has expanded over the last decade. However, the long-term performance of stent grafts, in particular durable fixation and sealing to the aortic wall, remains the main concern of this treatment. The sealing and fixation are challenged at every heartbeat due to downward and radial pulsatile forces. Yet knowledge on cardiac-induced dynamics of implanted stent grafts is sparse, as it is not measured in routine clinical follow-up. Such knowledge is particularly relevant to perform fatigue tests, to predict failure in the individual patient and to improve stent graft designs. Using a physical dynamic stent graft model in an anthropomorphic phantom, we have evaluated the performance of our previously proposed segmentation and registration algorithm to detect periodic motion of stent grafts on ECG-gated (3D+t) CT data. Abdominal aortic motion profiles were simulated in two series of Gaussian based patterns with different amplitudes and frequencies. Experiments were performed on a 64-slice CT scanner with a helical scan protocol and retrospective gating. Motion patterns as estimated by our algorithm were compared to motion patterns obtained from optical camera recordings of the physical stent graft model in motion. Absolute errors of the patterns' amplitude were smaller than 0.28 mm. Even the motion pattern with an amplitude of 0.23 mm was measured, although the amplitude of motion was overestimated by the algorithm with 43%. We conclude that the algorithm performs well for measurement of stent graft motion in the mm and sub-mm range. This ultimately is expected to aid in patient-specific risk assessment and improving stent graft designs.
Fitzpatrick, Benjamin M; Johnson, Jarrett R; Kump, D Kevin; Shaffer, H Bradley; Smith, Jeramiah J; Voss, S Randal
2009-07-24
Hybrid zones represent valuable opportunities to observe evolution in systems that are unusually dynamic and where the potential for the origin of novelty and rapid adaptation co-occur with the potential for dysfunction. Recently initiated hybrid zones are particularly exciting evolutionary experiments because ongoing natural selection on novel genetic combinations can be studied in ecological time. Moreover, when hybrid zones involve native and introduced species, complex genetic patterns present important challenges for conservation policy. To assess variation of admixture dynamics, we scored a large panel of markers in five wild hybrid populations formed when Barred Tiger Salamanders were introduced into the range of California Tiger Salamanders. At three of 64 markers, introduced alleles have largely displaced native alleles within the hybrid populations. Another marker (GNAT1) showed consistent heterozygote deficits in the wild, and this marker was associated with embryonic mortality in laboratory F2's. Other deviations from equilibrium expectations were idiosyncratic among breeding ponds, consistent with highly stochastic demographic effects. While most markers retain native and introduced alleles in expected proportions, strong selection appears to be eliminating native alleles at a smaller set of loci. Such rapid fixation of alleles is detectable only in recently formed hybrid zones, though it might be representative of dynamics that frequently occur in nature. These results underscore the variable and mosaic nature of hybrid genomes and illustrate the potency of recombination and selection in promoting variable, and often unpredictable genetic outcomes. Introgression of a few, strongly selected introduced alleles should not necessarily affect the conservation status of California Tiger Salamanders, but suggests that genetically pure populations of this endangered species will be difficult to maintain.
Fitzpatrick, Benjamin M; Johnson, Jarrett R; Kump, D Kevin; Shaffer, H Bradley; Smith, Jeramiah J; Voss, S Randal
2009-01-01
Background Hybrid zones represent valuable opportunities to observe evolution in systems that are unusually dynamic and where the potential for the origin of novelty and rapid adaptation co-occur with the potential for dysfunction. Recently initiated hybrid zones are particularly exciting evolutionary experiments because ongoing natural selection on novel genetic combinations can be studied in ecological time. Moreover, when hybrid zones involve native and introduced species, complex genetic patterns present important challenges for conservation policy. To assess variation of admixture dynamics, we scored a large panel of markers in five wild hybrid populations formed when Barred Tiger Salamanders were introduced into the range of California Tiger Salamanders. Results At three of 64 markers, introduced alleles have largely displaced native alleles within the hybrid populations. Another marker (GNAT1) showed consistent heterozygote deficits in the wild, and this marker was associated with embryonic mortality in laboratory F2's. Other deviations from equilibrium expectations were idiosyncratic among breeding ponds, consistent with highly stochastic demographic effects. Conclusion While most markers retain native and introduced alleles in expected proportions, strong selection appears to be eliminating native alleles at a smaller set of loci. Such rapid fixation of alleles is detectable only in recently formed hybrid zones, though it might be representative of dynamics that frequently occur in nature. These results underscore the variable and mosaic nature of hybrid genomes and illustrate the potency of recombination and selection in promoting variable, and often unpredictable genetic outcomes. Introgression of a few, strongly selected introduced alleles should not necessarily affect the conservation status of California Tiger Salamanders, but suggests that genetically pure populations of this endangered species will be difficult to maintain. PMID:19630983
2018-01-01
This study compares the differences and similarities of two types of superplasticizers—NSF (Naphthalene Sulfonate Formaldehyde) and PCE (PolyCarboxylate Ester)—in fresh cement paste systems, in terms of adsorption, dynamic yield stress, and thixotropic index. Results show that with either NSF or PCE addition, the more superplasticizer is added, the more it is adsorbed and the more it remains in the interstitial pore solution. The dynamic yield stress and thixotropic index also decrease with increasing addition the amount of either superplasticizer. However, NSF is less efficient in decreasing the dynamic yield stress than PCE. More importantly, the decreasing patterns of dynamic yield stress and thixotropic index are different with NSF and PCE additions; this is tied to the adsorption and dispersing mechanisms of these two types of superplasticizers. PMID:29710782
Outcome of limb reconstruction system in open tibial diaphyseal fractures.
Ajmera, Anand; Verma, Ankit; Agrawal, Mukul; Jain, Saurabh; Mukherjee, Arunangshu
2015-01-01
Management of open tibial diaphyseal fractures with bone loss is a matter of debate. The treatment options range from external fixators, nailing, ring fixators or grafting with or without plastic reconstruction. All the procedures have their own set of complications, like acute docking problems, shortening, difficulty in soft tissue management, chronic infection, increased morbidity, multiple surgeries, longer hospital stay, mal union, nonunion and higher patient dissatisfaction. We evaluated the outcome of the limb reconstruction system (LRS) in the treatment of open fractures of tibial diaphysis with bone loss as a definative mode of treatment to achieve union, as well as limb lengthening, simultaneously. Thirty open fractures of tibial diaphysis with bone loss of at least 4 cm or more with a mean age 32.5 years were treated by using the LRS after debridement. Distraction osteogenesis at rate of 1 mm/day was done away from the fracture site to maintain the limb length. On the approximation of fracture ends, the dynamized LRS was left for further 15-20 weeks and patient was mobilized with weight bearing to achieve union. Functional assessment was done by Association for the Study and Application of the Methods of Illizarov (ASAMI) criteria. Mean followup period was 15 months. The mean bone loss was 5.5 cm (range 4-9 cm). The mean duration of bone transport was 13 weeks (range 8-30 weeks) with a mean time for LRS in place was 44 weeks (range 24-51 weeks). The mean implant index was 56.4 days/cm. Mean union time was 52 weeks (range 31-60 weeks) with mean union index of 74.5 days/cm. Bony results as per the ASAMI scoring were excellent in 76% (19/25), good in 12% (3/25) and fair in 4% (1/25) with union in all except 2 patients, which showed poor results (8%) with only 2 patients having leg length discrepancy more than 2.5 cm. Functional results were excellent in 84% (21/25), good in 8% (2/25), fair in 8% (2/25). Pin tract infection was seen in 5 cases, out of which 4 being superficial, which healed to dressings and antibiotics. One patient had a deep infection which required frame removal. Limb reconstruction system proved to be an effective modality of treatment in cases of open fractures of the tibia with bone loss as definite modality of treatment for damage control as well as for achieving union and lengthening, simultaneously, with the advantage of early union with attainment of limb length, simple surgical technique, minimal invasive, high patient compliance, easy wound management, lesser hospitalization and the lower rate of complications like infection, deformity or shortening.
Cai, Xiaoni; Gao, Kunshan
2015-01-01
While the diazotrophic cyanobacterium Trichodesmium is known to display inverse diurnal performances of photosynthesis and N2 fixation, such a phenomenon has not been well documented under different day-night (L-D) cycles and different levels of light dose exposed to the cells. Here, we show differences in growth, N2 fixation and photosynthetic carbon fixation as well as photochemical performances of Trichodesmium IMS101 grown under 12L:12D, 8L:16D and 16L:8D L-D cycles at 70 μmol photons m-2 s-1 PAR (LL) and 350 μmol photons m-2 s-1 PAR (HL). The specific growth rate was the highest under LL and the lowest under HL under 16L:8D, and it increased under LL and decreased under HL with increased levels of daytime light doses exposed under the different light regimes, respectively. N2 fixation and photosynthetic carbon fixation were affected differentially by changes in the day-night regimes, with the former increasing directly under LL with increased daytime light doses and decreased under HL over growth-saturating light levels. Temporal segregation of N2 fixation from photosynthetic carbon fixation was evidenced under all day-night regimes, showing a time lag between the peak in N2 fixation and dip in carbon fixation. Elongation of light period led to higher N2 fixation rate under LL than under HL, while shortening the light exposure to 8 h delayed the N2 fixation peaking time (at the end of light period) and extended it to night period. Photosynthetic carbon fixation rates and transfer of light photons were always higher under HL than LL, regardless of the day-night cycles. Conclusively, diel performance of N2 fixation possesses functional plasticity, which was regulated by levels of light energy supplies either via changing light levels or length of light exposure.
Medial malleolar fractures: a biomechanical study of fixation techniques.
Fowler, T Ty; Pugh, Kevin J; Litsky, Alan S; Taylor, Benjamin C; French, Bruce G
2011-08-08
Fracture fixation of the medial malleolus in rotationally unstable ankle fractures typically results in healing with current fixation methods. However, when failure occurs, pullout of the screws from tension, compression, and rotational forces is predictable. We sought to biomechanically test a relatively new technique of bicortical screw fixation for medial malleoli fractures. Also, the AO group recommends tension-band fixation of small avulsion type fractures of the medial malleolus that are unacceptable for screw fixation. A well-documented complication of this technique is prominent symptomatic implants and secondary surgery for implant removal. Replacing stainless steel 18-gauge wire with FiberWire suture could theoretically decrease symptomatic implants. Therefore, a second goal was to biomechanically compare these 2 tension-band constructs. Using a tibial Sawbones model, 2 bicortical screws were compared with 2 unicortical cancellous screws on a servohydraulic test frame in offset axial, transverse, and tension loading. Second, tension-band fixation using stainless steel wire was compared with FiberWire under tensile loads. Bicortical screw fixation was statistically the stiffest construct under tension loading conditions compared to unicortical screw fixation and tension-band techniques with FiberWire or stainless steel wire. In fact, unicortical screw fixation had only 10% of the stiffness as demonstrated in the bicortical technique. In a direct comparison, tension-band fixation using stainless steel wire was statistically stiffer than the FiberWire construct. Copyright 2011, SLACK Incorporated.
Cavallari, Paolo; Bolzoni, Francesco; Bruttini, Carlo; Esposti, Roberto
2016-01-01
Anticipatory Postural Adjustments (APAs) are commonly described as unconscious muscular activities aimed to counterbalance the perturbation caused by the primary movement, so as to ensure the whole-body balance, as well as contributing to initiate the displacement of the body center of mass when starting gait or whole-body reaching movements. These activities usually create one or more fixation chains which spread over several muscles of different limbs, and may be thus called inter-limb APAs. However, it has been reported that APAs also precede voluntary movements involving tiny masses, like a flexion/extension of the wrist or even a brisk flexion of the index-finger. In particular, such movements are preceded by an intra-limb APA chain, that involves muscles acting on the proximal joints. Considering the small mass of the moving segments, it is unlikely that the ensuing perturbation could threaten the whole-body balance, so that it is interesting to enquire the physiological role of intra-limb APAs and their organization and control compared to inter-limb APAs. This review is focused on intra-limb APAs and highlights a strict correspondence in their behavior and temporal/spatial organization with respect to inter-limb APAs. Hence it is suggested that both are manifestations of the same phenomenon. Particular emphasis is given to intra-limb APAs preceding index-finger flexion, because their relatively simple biomechanics and the fact that muscular actions were limited to a single arm allowed peculiar investigations, leading to important conclusions. Indeed, such paradigm provided evidence that by granting a proper fixation of those body segments proximal to the moving one APAs are involved in refining movement precision, and also that APAs and prime mover activation are driven by a shared motor command. PMID:27807411
Krzepota, Justyna; Stępiński, Miłosz; Zwierko, Teresa
2016-12-01
Experienced and less experienced soccer players were compared in terms of their gaze behavior (number of fixations, fixation duration, number of fixation regions, and distribution of fixations across specific regions) during frontal 1 vs. 1 defensive situations. Twenty-four men (eight experienced soccer players, eight less experienced players and eight non-players) watched 20 video clips. Gaze behavior was registered with an Eye Tracking System. The video scenes were analyzed frame-by-frame. Significant main effect of the group (experience) was observed for the number of fixation regions. Experienced soccer players had a lower number of fixation regions than the non-soccer players. Moreover, the former group presented with significantly larger percentage of fixations in the ball/foot region. These findings suggest that experienced players may use a more efficient search strategy than novices, involving fixation on a lesser number of areas in specific locations. © The Author(s) 2016.
An effective fixative for glucocorticoid receptors in fetal tissues
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koga, T.; Kurisu, K.
1982-01-01
As a preliminary study in an autoradiographic study of glucocorticoid (GC) receptor localization in orofacial tissues of mouse fetuses, a search was made to determine the most effective fixative for preservation of the GC-receptor complex. Twelve-day-old mouse fetuses were administered tritiated triamcinolone acetonide (/sup 3/H-TAC) intraamniotically and subsequently processed by one of the following three procedures: freeze-drying, prefixation with Karnovsky's fixative, or the catechin fixative (Karnovsky's fixative containing 1% D-catechin) and postfixation with osmium tetroxide. Light microscopic autoradiography and liquid scintillation counting of the specimens revealed that the catechin fixative gave the best results for fixation of the steroid-receptor complexmore » and preservation of tissue structure. Light and electron microscopic autoradiographic studies of the time course of the localization of /sup 3/H-TAC in palatal shelves supported the catechin fixative as being the most effective in preservation of GC-receptor or ligand complexes.« less
Intramedullary nail fixation of non-traditional fractures: Clavicle, forearm, fibula.
Dehghan, Niloofar; Schemitsch, Emil H
2017-06-01
Locked intramedullary fixation is a well-established technique for managing long-bone fractures. While intramedullary nail fixation of diaphyseal fractures in the femur, tibia, and humerus is well established, the same is not true for other fractures. Surgical fixations of clavicle, forearm and ankle are traditionally treated with plate and screw fixation. In some cases, fixation with an intramedullary device is possible, and may be advantageous. However, there is however a concern regarding a lack of rotational stability and fracture shortening. While new generation of locked intramedullary devices for fractures of clavicle, forearm and fibula are recently available, the outcomes are not as reliable as fixation with plates and screws. Further research in this area is warranted with high quality comparative studies, to investigate the outcomes and indication of these fractures treated with intramedullary nail devices compared to intramedullary nail fixation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Neural correlates of fixation duration in natural reading: Evidence from fixation-related fMRI.
Henderson, John M; Choi, Wonil; Luke, Steven G; Desai, Rutvik H
2015-10-01
A key assumption of current theories of natural reading is that fixation duration reflects underlying attentional, language, and cognitive processes associated with text comprehension. The neurocognitive correlates of this relationship are currently unknown. To investigate this relationship, we compared neural activation associated with fixation duration in passage reading and a pseudo-reading control condition. The results showed that fixation duration was associated with activation in oculomotor and language areas during text reading. Fixation duration during pseudo-reading, on the other hand, showed greater involvement of frontal control regions, suggesting flexibility and task dependency of the eye movement network. Consistent with current models, these results provide support for the hypothesis that fixation duration in reading reflects attentional engagement and language processing. The results also demonstrate that fixation-related fMRI provides a method for investigating the neurocognitive bases of natural reading. Copyright © 2015 Elsevier Inc. All rights reserved.
Porras, Ileana C; Hiscock, Merrill; Layne, Charles S
2015-12-01
Previous studies have shown that men can balance a dowel rod on the index finger for a longer time than women can. The factors that account for the difference are unknown, but the difference may be attributable either to a difference in whole-body agility or a difference in the use of visual cues. Three experiments involving a total of 62 adult women with a mean age of 21.2 yr. (SD=3.8) and 62 adult men with a mean age of 21.9 yr. (SD=6.6) tested these potential explanations. Experiment 1 replicated the sex difference and assessed the relevance of whole-body agility by comparing standing and seated conditions. Experiments 2 and 3 explored the role of rod length and visual fixation point, respectively. Each experiment yielded a significant sex difference, but the difference was not affected by the participant's posture, the length of the rod, or the fixation point. Possible alternative explanations for the difference include differences in (1) the speed of processing degree of visual tilt; (2) arm mass, which affects the inertia of the balancing system; and (3) experience in open-skill sports.
Early prophylactic autogenous bone grafting in type III open tibial fractures.
Kesemenli, Cumhur C; Kapukaya, Ahmet; Subaşi, Mehmet; Arslan, Huseyin; Necmioğlu, Serdar; Kayikçi, Cuma
2004-08-01
The authors report the results achieved in patients with type III open tibial fractures who underwent primary autogenous bone grafting at the time of debridement and skeletal stabilisation. Twenty patients with a mean age of 35.8 years (range, 24-55) were treated between 1996 and 1999. Eight fractures were type IIIA, 11 were type IIIB, and 1 was type IIIC. At the index procedure, wound debridement, external fixation and autogenous bone grafting with bone coverage were achieved. The mean follow-up period was 46 months (range, 34-55). The mean time to fixator removal was 21 weeks (range, 14-35), and the mean time to union was 28 weeks (range, 19-45). Skin coverage was achieved by a myocutaneous flap in 2 patients, late primary closure in 4, and split skin grafting in 14. One (5%) of the patients experienced delayed union, and 1 (5%) developed infection. In tibial type III open fractures, skin coverage may be delayed, using the surrounding soft tissue to cover any exposed bone after thorough débridement and wound cleansing. Primary prophylactic bone grafting performed at the same time reduces the rate of delayed union, shortens the time to union, and does not increase the infection rate.