Sample records for fixed block control

  1. Rate-Compatible LDPC Codes with Linear Minimum Distance

    NASA Technical Reports Server (NTRS)

    Divsalar, Dariush; Jones, Christopher; Dolinar, Samuel

    2009-01-01

    A recently developed method of constructing protograph-based low-density parity-check (LDPC) codes provides for low iterative decoding thresholds and minimum distances proportional to block sizes, and can be used for various code rates. A code constructed by this method can have either fixed input block size or fixed output block size and, in either case, provides rate compatibility. The method comprises two submethods: one for fixed input block size and one for fixed output block size. The first mentioned submethod is useful for applications in which there are requirements for rate-compatible codes that have fixed input block sizes. These are codes in which only the numbers of parity bits are allowed to vary. The fixed-output-blocksize submethod is useful for applications in which framing constraints are imposed on the physical layers of affected communication systems. An example of such a system is one that conforms to one of many new wireless-communication standards that involve the use of orthogonal frequency-division modulation

  2. 75 FR 55970 - Safety Zone; VERMILION 380A at Block 380 Outer Continental Shelf Fixed Platform in the Gulf of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-15

    ...-AA00 Safety Zone; VERMILION 380A at Block 380 Outer Continental Shelf Fixed Platform in the Gulf of... safety zone around VERMILION 380A, a fixed platform, at Block 380 in the Outer Continental Shelf, approximately 90 miles south of Vermilion Bay, Louisiana. The fixed platform is on fire and the safety zone is...

  3. Communications Based Train Control (CBTC) Before and After Cost Study

    DOT National Transportation Integrated Search

    2011-03-01

    San Francisco Municipal Railway (Muni) undertook a retrofit of a fixed-block signaling system with a communications-based train control (CBTC) system in the subway portion of their light rail system (Muni Metro subway) in 1998. This report presents t...

  4. Ad-hoc and context-dependent adjustments of selective attention in conflict control: an ERP study with visual probes.

    PubMed

    Nigbur, R; Schneider, J; Sommer, W; Dimigen, O; Stürmer, B

    2015-02-15

    Cognitive conflict control in flanker tasks has often been described using the zoom-lens metaphor of selective attention. However, whether and how selective attention - in terms of suppression and enhancement - operates in this context has remained unclear. To examine the dynamic interplay of selective attention and cognitive control we used electrophysiological measures and presented task-irrelevant visual probe stimuli at foveal, parafoveal, and peripheral display positions. Target-flanker congruency varied either randomly from trial to trial (mixed-block) or block-wise (fixed-block) in order to induce reactive versus proactive control modes, respectively. Three EEG measures were used to capture ad-hoc adjustments within trials as well as effects of context-based predictions: the N1 component of the visual evoked potential (VEP) to probes, the VEP to targets, and the conflict-related midfrontal N2 component. Results from probe-VEPs indicate that enhanced processing of the foveal target rather than suppression of the peripheral flankers supports interference control. In incongruent mixed-block trials VEPs were larger to probes near the targets. In the fixed-blocks probe-VEPs were not modulated, but contrary to the mixed-block the preceding target-related VEP was affected by congruency. Results of the control-related N2 reveal largest amplitudes in the unpredictable context, which did not differentiate for stimulus and response incongruency. In contrast, in the predictable context, N2 amplitudes were reduced overall and differentiated between stimulus and response incongruency. Taken together these results imply that predictability alters interference control by a reconfiguration of stimulus processing. During unpredictable sequences participants adjust their attentional focus dynamically on a trial-by-trial basis as reflected in congruency-dependent probe-VEP-modulation. This reactive control mode also elicits larger N2 amplitudes. In contrast, when task demands are predictable, participants focus selective attention earlier as reflected in the target-related VEPs. This proactive control mode leads to smaller N2 amplitudes and absent probe effects. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Fixed-Rate Compressed Floating-Point Arrays.

    PubMed

    Lindstrom, Peter

    2014-12-01

    Current compression schemes for floating-point data commonly take fixed-precision values and compress them to a variable-length bit stream, complicating memory management and random access. We present a fixed-rate, near-lossless compression scheme that maps small blocks of 4(d) values in d dimensions to a fixed, user-specified number of bits per block, thereby allowing read and write random access to compressed floating-point data at block granularity. Our approach is inspired by fixed-rate texture compression methods widely adopted in graphics hardware, but has been tailored to the high dynamic range and precision demands of scientific applications. Our compressor is based on a new, lifted, orthogonal block transform and embedded coding, allowing each per-block bit stream to be truncated at any point if desired, thus facilitating bit rate selection using a single compression scheme. To avoid compression or decompression upon every data access, we employ a software write-back cache of uncompressed blocks. Our compressor has been designed with computational simplicity and speed in mind to allow for the possibility of a hardware implementation, and uses only a small number of fixed-point arithmetic operations per compressed value. We demonstrate the viability and benefits of lossy compression in several applications, including visualization, quantitative data analysis, and numerical simulation.

  6. New horizons in orthodontics & dentofacial orthopedics: fixed Twin Blocks & TransForce lingual appliances.

    PubMed

    Clark, William John

    2011-01-01

    During the 20th century functional appliances evolved from night time wear to more flexible appliances for increased day time wear to full time wear with Twin Block appliances. The current trend is towards fixed functional appliances and this paper introduces the Fixed Twin Block, bonded to the teeth to eliminate problems of compliance in functional therapy. TransForce lingual appliances are pre-activated and may be used in first phase treatment for sagittal and transverse arch development. Alternatively they may be integrated with fixed appliances at any stage of treatment.

  7. An effective detection algorithm for region duplication forgery in digital images

    NASA Astrophysics Data System (ADS)

    Yavuz, Fatih; Bal, Abdullah; Cukur, Huseyin

    2016-04-01

    Powerful image editing tools are very common and easy to use these days. This situation may cause some forgeries by adding or removing some information on the digital images. In order to detect these types of forgeries such as region duplication, we present an effective algorithm based on fixed-size block computation and discrete wavelet transform (DWT). In this approach, the original image is divided into fixed-size blocks, and then wavelet transform is applied for dimension reduction. Each block is processed by Fourier Transform and represented by circle regions. Four features are extracted from each block. Finally, the feature vectors are lexicographically sorted, and duplicated image blocks are detected according to comparison metric results. The experimental results show that the proposed algorithm presents computational efficiency due to fixed-size circle block architecture.

  8. MQ-9 Reaper Unmanned Aircraft System (MQ-9 Reaper)

    DTIC Science & Technology

    2013-12-01

    Milestone C ACAT II Block 1 FEB 2008 FEB 2008 FEB 2008 FEB 2008 IOT&E for Block 1 MAY 2008 MAY 2008 MAY 2008 MAY 2008 RAA SEP 2010 JUN 2012 JUN 2012 JUN...milestone change. Memo MQ-9 Reaper December 2013 SAR April 16, 2014 17:17:09 UNCLASSIFIED 9 RAA includes two fixed GCSs, two mobile GCSs...Control Station IOT&E - Initial Operational Test and Evaluation PMAI - Primary Mission Aircraft Inventory PO - Program Office RAA - Required Assets

  9. Treatment effects produced by the Twin-block appliance vs the Forsus Fatigue Resistant Device in growing Class II patients.

    PubMed

    Giuntini, Veronica; Vangelisti, Andrea; Masucci, Caterina; Defraia, Efisio; McNamara, James A; Franchi, Lorenzo

    2015-09-01

    To compare the dentoskeletal changes produced by the Twin-block appliance (TB) followed by fixed appliances vs the Forsus Fatigue Resistant Device (FRD) in combination with fixed appliances in growing patients having Class II division 1 malocclusion. Twenty-eight Class II patients (19 females and 9 males; mean age, 12.4 years) treated consecutively with the TB followed by fixed appliances were compared with a group of 36 patients (16 females and 20 males; mean age, 12.3 years) treated consecutively with the FRD in combination with fixed appliances and with a sample of 27 subjects having untreated Class II malocclusion (13 females and 14 males; mean age, 12.2 years). Mean observation interval was 2.3 years in all groups. Cephalometric changes were compared among the three groups by means of ANOVA and Tukey's post hoc tests. The FRD produced a significant restraint of the maxilla compared with the TB and control samples (SNA, -1.1° and -1.8°, respectively). The TB sample exhibited significantly greater mandibular advancement and greater increments in total mandibular length than either the FRD or control groups (SNB, 1.9° and 1.5°, respectively; and Co-Gn, 2.0 mm and 3.4 mm, respectively). The FRD produced a significantly greater amount of proclination of the mandibular incisors than what occurred with the TB or the control samples (2.9° and 5.6°, respectively). The TB appliance produced greater skeletal effects in terms of mandibular advancement and growth stimulation while the Forsus caused significant proclination of the mandibular incisors.

  10. Determining Optimal Microwave Antigen Retrieval Conditions for Microtubule-Associated Protein 2 Immunohistochemistry in the Guinea Pig Brain

    DTIC Science & Technology

    2002-12-01

    sections of formalin-fixed guinea pig brains using different MAP-2 monoclonal antibodies. Brain sections were boiled in sodium citrate, citric acid...citric acid solution at pH 6.0 is the optimal microwave-assisted AR method for immunolabeling MAP-2 in formalin-fixed, paraffin-processed guinea pig brain...studies on archival guinea pig brain paraffin blocks, ultimately relaxing the use of additional animals to evaluate changes in MAP-2 expression between chemical warfare nerve agent-treated and control samples.

  11. Controlling block copolymer phase behavior using ionic surfactant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ray, D.; Aswal, V. K.

    2016-05-23

    The phase behavior of poly(ethylene oxide)-poly(propylene oxide-poly(ethylene oxide) PEO-PPO-PEO triblock copolymer [P85 (EO{sub 26}PO{sub 39}EO{sub 26})] in presence of anionic surfactant sodium dodecyl sulfate (SDS) in aqueous solution as a function of temperature has been studied using dynamic light scattering (DLS) and small-angle neutron scattering (SANS). The measurements have been carried out for fixed concentrations (1 wt%) of block copolymer and surfactants. Each of the individual components (block copolymer and surfactant) and the nanoparticle–surfactant mixed system have been examined at varying temperature. The block copolymer P85 forms spherical micelles at room temperature whereas shows sphere-to-rod like micelle transition at highermore » temperatures. On the other hand, SDS surfactant forms ellipsoidal micelles over a wide temperature range. Interestingly, it is found that phase behavior of mixed micellar system (P85 + SDS) as a function of temperature is drastically different from that of P85, giving the control over the temperature-dependent phase behavior of block copolymers.« less

  12. Microphase separation in random multiblock copolymers

    NASA Astrophysics Data System (ADS)

    Govorun, E. N.; Chertovich, A. V.

    2017-01-01

    Microphase separation in random multiblock copolymers is studied with the mean-field theory assuming that long blocks of a copolymer are strongly segregated, whereas short blocks are able to penetrate into "alien" domains and exchange between the domains and interfacial layer. A bidisperse copolymer with blocks of only two sizes (long and short) is considered as a model of multiblock copolymers with high polydispersity in the block size. Short blocks of the copolymer play an important role in the microphase separation. First, their penetration into the "alien" domains leads to the formation of joint long blocks in their own domains. Second, short blocks localized at the interface considerably change the interfacial tension. The possibility of penetration of short blocks into the "alien" domains is controlled by the product χ Nsh (χ is the Flory-Huggins interaction parameter and Nsh is the short block length). At not very large χ Nsh , the domain size is larger than that for a regular copolymer consisting of the same long blocks as in the considered random copolymer. At a fixed mean block size, the domain size grows with an increase in the block size dispersity, the rate of the growth being dependent of the more detailed parameters of the block size distribution.

  13. Protein extraction from methanol fixed paraffin embedded tissue blocks: A new possibility using cell blocks

    PubMed Central

    Kokkat, Theresa J.; McGarvey, Diane; Patel, Miral S.; Tieniber, Andrew D.; LiVolsi, Virginia A.; Baloch, Zubair W.

    2013-01-01

    Background: Methanol fixed and paraffin embedded (MFPE) cellblocks are an essential cytology preparation. However, MFPE cellblocks often contain limited material and their relatively small size has caused them to be overlooked in biomarker discovery. Advances in the field of molecular biotechnology have made it possible to extract proteins from formalin fixed and paraffin embedded (FFPE) tissue blocks. In contrast, there are no established methods for extracting proteins from MFPE cellblocks. We investigated commonly available CHAPS (3-[(3-cholamidopropyl) dimethylammonio]-1-propanesulfonate) buffer, as well as two commercially available Qiagen® kits and compared their effectiveness on MFPE tissue for protein yields. Materials and Methods: MFPE blocks were made by Cellient™ automated system using human tissue specimens from normal and malignant specimens collected in ThinPrep™ Vials. Protein was extracted from Cellient-methanol fixed and paraffin embedded blocks with CHAPS buffer method as well as FFPE and Mammalian Qiagen® kits. Results: Comparison of protein yields demonstrated the effectiveness of various protein extraction methods on MFPE cellblocks. Conclusion: In the current era of minimally invasive techniques to obtain minimal amount of tissue for diagnostic and prognostic purposes, the use of commercial and lab made buffer on low weight MFPE scrapings obtained by Cellient® processor opens new possibilities for protein biomarker research. PMID:24403950

  14. General Mechanism of Morphology Transition and Spreading Area-dependent Phase Diagram of Block Copolymer Self-assembly at the Air/Water Interface

    NASA Astrophysics Data System (ADS)

    Kim, Dong Hyup; Kim, So Youn

    Block copolymers (BCPs) can be self-assembled forming periodic nanostructures, which have been employed in many applications. While general agreements exist for the phase diagrams of BCP self-assembly in bulk or thin films, a fundamental understanding of BCP structures at the air/water interface still remain elusive. The current study explains morphology transition of BCPs with relative fraction of each block at the air/water interface: block fraction is the only parameter to control the morphology. In this study, we show morphology transitions from spherical to cylindrical and planar structures with neat polystyrene-b-poly(2-vinylpyridine) (PS-b-P2VP) via reducing the spreading area of BCP solution at the air/water interface. For example, PS-b-P2VP in a fixed block fraction known to form only spheres can experience sphere to cylinder or lamellar transitions depending on the spreading area at the air/water interface. Suggesting a new parameter to control the interfacial assembly of BCPs, a complete phase diagram is drawn with two paramters: relative block fraction and spreading area. We also explain the morphology transition with the combinational description of dewetting mechanism and spring effect of hydrophilic block.

  15. Weather Impact on Airport Arrival Meter Fix Throughput

    NASA Technical Reports Server (NTRS)

    Wang, Yao

    2017-01-01

    Time-based flow management provides arrival aircraft schedules based on arrival airport conditions, airport capacity, required spacing, and weather conditions. In order to meet a scheduled time at which arrival aircraft can cross an airport arrival meter fix prior to entering the airport terminal airspace, air traffic controllers make regulations on air traffic. Severe weather may create an airport arrival bottleneck if one or more of airport arrival meter fixes are partially or completely blocked by the weather and the arrival demand has not been reduced accordingly. Under these conditions, aircraft are frequently being put in holding patterns until they can be rerouted. A model that predicts the weather impacted meter fix throughput may help air traffic controllers direct arrival flows into the airport more efficiently, minimizing arrival meter fix congestion. This paper presents an analysis of air traffic flows across arrival meter fixes at the Newark Liberty International Airport (EWR). Several scenarios of weather impacted EWR arrival fix flows are described. Furthermore, multiple linear regression and regression tree ensemble learning approaches for translating multiple sector Weather Impacted Traffic Indexes (WITI) to EWR arrival meter fix throughputs are examined. These weather translation models are developed and validated using the EWR arrival flight and weather data for the period of April-September in 2014. This study also compares the performance of the regression tree ensemble with traditional multiple linear regression models for estimating the weather impacted throughputs at each of the EWR arrival meter fixes. For all meter fixes investigated, the results from the regression tree ensemble weather translation models show a stronger correlation between model outputs and observed meter fix throughputs than that produced from multiple linear regression method.

  16. Validation of a standardized extraction method for formalin-fixed paraffin-embedded tissue samples.

    PubMed

    Lagheden, Camilla; Eklund, Carina; Kleppe, Sara Nordqvist; Unger, Elizabeth R; Dillner, Joakim; Sundström, Karin

    2016-07-01

    Formalin-fixed paraffin-embedded (FFPE) samples can be DNA-extracted and used for human papillomavirus (HPV) genotyping. The xylene-based gold standard for extracting FFPE samples is laborious, suboptimal and involves health hazards for the personnel involved. To compare extraction with the standard xylene method to a xylene-free method used in an HPV LabNet Global Reference Laboratory at the Centers for Disease Control (CDC); based on a commercial method with an extra heating step. Fifty FFPE samples were randomly selected from a national audit of all cervical cancer cases diagnosed in Sweden during 10 years. For each case-block, a blank-block was sectioned, as a control for contamination. For xylene extraction, the standard WHO Laboratory Manual protocol was used. For the CDC method, the manufacturers' protocol was followed except for an extra heating step, 120°C for 20min. Samples were extracted and tested in parallel with β-globin real-time PCR, HPV16 real-time PCR and HPV typing using modified general primers (MGP)-PCR and Luminex assays. For a valid result the blank-block had to be betaglobin-negative in all tests and the case-block positive for beta-globin. Overall, detection was improved with the heating method and the amount of HPV-positive samples increased from 70% to 86% (p=0.039). For all samples where HPV type concordance could be evaluated, there was 100% type concordance. A xylene-free and robust extraction method for HPV-DNA typing in FFPE material is currently in great demand. Our proposed standardized protocol appears to be generally useful. Copyright © 2016. Published by Elsevier B.V.

  17. Probabilistic Motor Sequence Yields Greater Offline and Less Online Learning than Fixed Sequence

    PubMed Central

    Du, Yue; Prashad, Shikha; Schoenbrun, Ilana; Clark, Jane E.

    2016-01-01

    It is well acknowledged that motor sequences can be learned quickly through online learning. Subsequently, the initial acquisition of a motor sequence is boosted or consolidated by offline learning. However, little is known whether offline learning can drive the fast learning of motor sequences (i.e., initial sequence learning in the first training session). To examine offline learning in the fast learning stage, we asked four groups of young adults to perform the serial reaction time (SRT) task with either a fixed or probabilistic sequence and with or without preliminary knowledge (PK) of the presence of a sequence. The sequence and PK were manipulated to emphasize either procedural (probabilistic sequence; no preliminary knowledge (NPK)) or declarative (fixed sequence; with PK) memory that were found to either facilitate or inhibit offline learning. In the SRT task, there were six learning blocks with a 2 min break between each consecutive block. Throughout the session, stimuli followed the same fixed or probabilistic pattern except in Block 5, in which stimuli appeared in a random order. We found that PK facilitated the learning of a fixed sequence, but not a probabilistic sequence. In addition to overall learning measured by the mean reaction time (RT), we examined the progressive changes in RT within and between blocks (i.e., online and offline learning, respectively). It was found that the two groups who performed the fixed sequence, regardless of PK, showed greater online learning than the other two groups who performed the probabilistic sequence. The groups who performed the probabilistic sequence, regardless of PK, did not display online learning, as indicated by a decline in performance within the learning blocks. However, they did demonstrate remarkably greater offline improvement in RT, which suggests that they are learning the probabilistic sequence offline. These results suggest that in the SRT task, the fast acquisition of a motor sequence is driven by concurrent online and offline learning. In addition, as the acquisition of a probabilistic sequence requires greater procedural memory compared to the acquisition of a fixed sequence, our results suggest that offline learning is more likely to take place in a procedural sequence learning task. PMID:26973502

  18. Probabilistic Motor Sequence Yields Greater Offline and Less Online Learning than Fixed Sequence.

    PubMed

    Du, Yue; Prashad, Shikha; Schoenbrun, Ilana; Clark, Jane E

    2016-01-01

    It is well acknowledged that motor sequences can be learned quickly through online learning. Subsequently, the initial acquisition of a motor sequence is boosted or consolidated by offline learning. However, little is known whether offline learning can drive the fast learning of motor sequences (i.e., initial sequence learning in the first training session). To examine offline learning in the fast learning stage, we asked four groups of young adults to perform the serial reaction time (SRT) task with either a fixed or probabilistic sequence and with or without preliminary knowledge (PK) of the presence of a sequence. The sequence and PK were manipulated to emphasize either procedural (probabilistic sequence; no preliminary knowledge (NPK)) or declarative (fixed sequence; with PK) memory that were found to either facilitate or inhibit offline learning. In the SRT task, there were six learning blocks with a 2 min break between each consecutive block. Throughout the session, stimuli followed the same fixed or probabilistic pattern except in Block 5, in which stimuli appeared in a random order. We found that PK facilitated the learning of a fixed sequence, but not a probabilistic sequence. In addition to overall learning measured by the mean reaction time (RT), we examined the progressive changes in RT within and between blocks (i.e., online and offline learning, respectively). It was found that the two groups who performed the fixed sequence, regardless of PK, showed greater online learning than the other two groups who performed the probabilistic sequence. The groups who performed the probabilistic sequence, regardless of PK, did not display online learning, as indicated by a decline in performance within the learning blocks. However, they did demonstrate remarkably greater offline improvement in RT, which suggests that they are learning the probabilistic sequence offline. These results suggest that in the SRT task, the fast acquisition of a motor sequence is driven by concurrent online and offline learning. In addition, as the acquisition of a probabilistic sequence requires greater procedural memory compared to the acquisition of a fixed sequence, our results suggest that offline learning is more likely to take place in a procedural sequence learning task.

  19. A case study of sea breeze blocking regulated by sea surface temperature along the English south coast

    NASA Astrophysics Data System (ADS)

    Sweeney, J. K.; Chagnon, J. M.; Gray, S. L.

    2014-05-01

    The sensitivity of sea breeze structure to sea surface temperature (SST) and coastal orography is investigated in convection-permitting Met Office Unified Model simulations of a case study along the south coast of England. Changes in SST of 1 K are shown to significantly modify the structure of the sea breeze immediately offshore. On the day of the case study, the sea breeze was partially blocked by coastal orography, particularly within Lyme Bay. The extent to which the flow is blocked depends strongly on the static stability of the marine boundary layer. In experiments with colder SST, the marine boundary layer is more stable, and the degree of blocking is more pronounced. Although a colder SST would also imply a larger land-sea temperature contrast and hence a stronger onshore wind - an effect which alone would discourage blocking - the increased static stability exerts a dominant control over whether blocking takes place. The implications of prescribing fixed SST from climatology in numerical weather prediction model forecasts of the sea breeze are discussed.

  20. Fixed-Wing Micro Aerial Vehicle for Accurate Corridor Mapping

    NASA Astrophysics Data System (ADS)

    Rehak, M.; Skaloud, J.

    2015-08-01

    In this study we present a Micro Aerial Vehicle (MAV) equipped with precise position and attitude sensors that together with a pre-calibrated camera enables accurate corridor mapping. The design of the platform is based on widely available model components to which we integrate an open-source autopilot, customized mass-market camera and navigation sensors. We adapt the concepts of system calibration from larger mapping platforms to MAV and evaluate them practically for their achievable accuracy. We present case studies for accurate mapping without ground control points: first for a block configuration, later for a narrow corridor. We evaluate the mapping accuracy with respect to checkpoints and digital terrain model. We show that while it is possible to achieve pixel (3-5 cm) mapping accuracy in both cases, precise aerial position control is sufficient for block configuration, the precise position and attitude control is required for corridor mapping.

  1. Perceived facial changes of Class II Division 1 patients with convex profiles after functional orthopedic treatment followed by fixed orthodontic appliances.

    PubMed

    Tsiouli, Kleopatra; Topouzelis, Nikolaos; Papadopoulos, Moschos A; Gkantidis, Nikolaos

    2017-07-01

    The aim of this research was to investigate the perceived facial changes in Class II Division 1 patients with convex profiles after functional orthopedic treatment followed by fixed orthodontic appliances. Pretreatment and posttreatment profile photographs of 12 Class II Division 1 patients treated with activators, 12 Class II Division 1 patients treated with Twin-block appliances, and 12 controls with normal profiles treated without functional appliances were presented in pairs to 10 orthodontists, 10 patients, 10 parents, and 10 laypersons. The raters assessed changes in facial appearance on a visual analog scale. Two-way multivariate analysis of variance was used to evaluate differences among group ratings. Intrarater reliability was strong in most cases (intraclass correlation coefficients, >0.7). The internal consistency of the assessments was high (alpha, >0.87), both within and between groups. The raters consistently perceived more positive changes in the Class II Division 1 groups compared with the control group. However, this difference hardly exceeded 1/10th of the total visual analog scale length in its highest value and was mostly evident in the lower face and chin. No significant differences were found between the activator and the Twin-block groups. Although the raters perceived improvements of the facial profiles after functional orthopedic treatment followed by fixed orthodontic appliances, these were quite limited. Thus, orthodontists should be tentative when predicting significant improvement of a patient's profile with this treatment option. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  2. Experimental verification of using nanostructured ceramic implants and osteograft

    NASA Astrophysics Data System (ADS)

    Rerikh, V. V.; Lastevskiy, A. D.; Sadovoy, M. A.; Zaidman, A. M.; Bataev, A. V.; Predein, Yu. A.; Avetisyan, A. R.; Romanenko, V. V.; Mamonova, E. V.; Nikulina, A. A.; Semantsova, E. S.; Smirnov, A. I.

    2017-09-01

    Ventral interbody fusion was carried out in 8 mini pigs in order to determine the effectiveness of anterior stabilization of the vertebral unit with implants made of nanostructured alumina ceramics using cellular technologies to form a bone block. A ceramic cage with a through cylindrical orifice in the center was implanted into the interbody gap; either cellular osteograft (group 1) or cellular autograft (group 2) was placed in it. The adjacent vertebrae were fixed anteriorly with a ceramic plate containing 4 screws. Bone block formation was studied radiographically, morphologically, and by MSCT. The signs of osteointegration of ceramic implants were observed in both groups after 90 days. MSCT and morphological analysis revealed the formation of the osteoceramic block and completed osteogenesis in the bone-graft contact region in group 1 compared to the control group (p < 0.05).

  3. The influence of ozone forcing on blocking in the Southern Hemisphere

    NASA Astrophysics Data System (ADS)

    Dennison, Fraser W.; McDonald, Adrian; Morgenstern, Olaf

    2016-12-01

    We investigate the influence of ozone depletion and recovery on tropospheric blocking in the Southern Hemisphere. Blocking events are identified using a persistent positive anomaly method applied to 500 hPa geopotential height. Using the National Institute for Water and Atmospheric Research-United Kingdom Chemistry and Aerosols chemistry-climate model, we compare reference runs that include forcing due to greenhouse gases (GHGs) and ozone-depleting substances to sensitivity simulations in which ozone-depleting substances are fixed at their 1960 abundances and other sensitivity simulations with GHGs fixed at their 1960 abundances. Blocking events in the South Atlantic are shown to follow stratospheric positive anomalies in the Southern Annular Mode (SAM) index; this is not the case for South Pacific blocking events. This relationship means that summer ozone depletion, and corresponding positive SAM anomalies, leads to an increased frequency of blocking in the South Atlantic while having little effect in the South Pacific. Similarly, ozone recovery, having the opposite effect on the SAM, leads to a decline in blocking frequency in the South Atlantic, although this may be somewhat counteracted by the effect of increasing GHGs.

  4. Microwave energy fixation for electron microscopy.

    PubMed Central

    Login, G. R.; Dvorak, A. M.

    1985-01-01

    We have demonstrated that microwave energy (MW) can be used in conjunction with chemical cross-linking agents in order to rapidly fix cell suspensions and tissue blocks for electron microscopy in 7-9 seconds. The optimal MW fixation method involved immersing tissues up to 1 cu cm in dilute aldehyde fixation and immediately irradiating the specimens in a conventional microwave oven for 9 seconds to 50 C. Ultrastructural preservation of samples irradiated by MW energy was comparable to that of the control samples immersed in aldehyde fixative for 2 hours at 25 C. Stereologic analysis showed that tissue blocks fixed by the MW fixation method did not cause organelles such as liver mitochondria and salivary gland granules to shrink or to swell. Potential applications for this new fixation technology include the investigation of rapid intracellular processes (eg, vesicular transport) and preservation of proteins that are difficult to demonstrate with routine fixation methods (eg, antigens and enzymes). Images Figure 4 Figure 5 Figure 2 Figure 3 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 PMID:3927740

  5. Biodegradable thermoplastic polyurethanes incorporating polyhedral oligosilsesquioxane.

    PubMed

    Knight, Pamela T; Lee, Kyung Min; Qin, Haihu; Mather, Patrick T

    2008-09-01

    A new hybrid thermoplastic polyurethane (TPU) system that incorporates an organic, biodegradable poly(D, L-lactide) soft block with a hard block bearing the inorganic polyhedral oligosilsesquioxane (POSS) moiety is introduced and studied. Changes in the polyol composition made through variation of the hydrophilic initiator molecular weight show direct control of the final transition temperatures. Incorporating POSS into the hard segments allows for excellent elasticity above T(g), as evidenced with dynamic mechanical analysis, not seen in most other biodegradable materials. This elasticity is attributed to physical cross-links formed in the hard block through POSS crystallization, as revealed with wide-angle X-ray diffraction. Increasing the POSS incorporation level in the TPU hard block was observed to increase crystallinity and also the rigidity of the material. The highest incorporation, using a statistical average of three POSS units per hard block, demonstrated one-way shape memory with excellent shape fixing capabilities. In vitro degradation of this sample was also investigated during a two month period. Moderate water uptake and dramatic molecular weight decrease were immediately observed although large mass loss (approximately 20 wt %) was not observed until the two month time point.

  6. A Design Selection Procedure.

    ERIC Educational Resources Information Center

    Kroeker, Leonard P.

    The problem of blocking on a status variable was investigated. The one-way fixed-effects analysis of variance, analysis of covariance, and generalized randomized block designs each treat the blocking problem in a different way. In order to compare these designs, it is necessary to restrict attention to experimental situations in which observations…

  7. Reactor hold-down arrangement

    DOEpatents

    McCugh, Ralph

    1976-05-25

    A nuclear reactor contains an assembly of moderator blocks, laid end-to-end, one on top of another, and alongside one another, which blocks are restrained by vertical beams at each side of the assembly, fixed horizontal beams surrounding the assembly at the top and bottom and springs connecting the fixed horizontal beams and the ends of the vertical beams in such a way as to permit relatively high expansion midway of the height of the assembly while restricting expansion near the top of the assembly.

  8. An evaluation of oral health-related quality of life in orthodontic patients treated with fixed and twin blocks appliances.

    PubMed

    Alzoubi, Emad Em; Hariri, Racha; Mulligan, Kevin; Attard, Nikolai

    2017-01-01

    To study the impact of orthodontic treatment on the quality of life in two patient groups, one treated with the twin block appliance and the other with fixed appliances. Ninety-eight patients, aged between 10 and 16 years, were recruited in the fixed (20 males and 29 females) or functional (29 males and 20 females) treatment groups. The oral health-related quality of life (OHRQoL) was measured before treatment and followed up at the end of the treatment. The instrument used to measure OHRQoL was a modified self-administered short version of the English Oral Health Impact profile (OHIP-16[E]) questionnaire. OHRQoL worsened at the initial stages of the treatment. The overall score of OHRQoL reduced significantly at the end of the treatment in both groups. Both groups showed comparable improvements in OHRQoL as the treatment progressed (analysis of variance test P = 0.05). The OHRQoL patterns, during the treatment with fixed and twin block appliances, were very similar. This suggests that the functional appliance's impact on the QoL may be overestimates by clinicians. OHRQoL improved significantly with both fixed and functional appliances by the end of the treatment. The OHRQoL trends observed during the study can be communicated to patients and used to increase patients' compliance since they are made aware of the whole treatment process.

  9. Double network physical gels from elastin-like polypeptide block copolymers: nanoscale control of thermoresponsive reinforcement

    NASA Astrophysics Data System (ADS)

    Glassman, Matthew; Olsen, Bradley

    2014-03-01

    Triblock copolymers with associative protein midblocks and thermoresponsive endblocks form shear thinning hydrogels with a low yield stress at low temperatures, but can be reinforced by a self-assembled network of the endblock aggregates. Here, we compare the use of bioengineered elastin-like polypeptides (ELPs) to synthetic poly(N-isopropylacrylamide) (PNIPAM) as endblocks to control the self-assembly of the reinforcing network. The temperature dependence of the mechanics of these hydrogels is a strong function of the domain size and morphology in the endblock network. Despite the architectural similarities, triblock ELP fusions and PNIPAM bioconjugates exhibit distinct reinforcement maxima at fixed block composition and polymer concentration, and these differences can be attributed to the nanostructural features of the two systems. Furthermore, in ELP fusions, the amino acid sequence can be readily modified to manipulate the solvation kinetics of the endblock domains. Finally, various endblocks have been combined to form triblock terpolymer hydrogels, demonstrating how the choice of thermoresponsive blocks can be used to tune the reinforcement of shear thinning hydrogels.

  10. Widely Tunable Morphologies in Block Copolymer Thin Films Through Solvent Vapor Annealing Using Mixtures of Selective Solvents

    PubMed Central

    Chavis, Michelle A.; Smilgies, Detlef-M.; Wiesner, Ulrich B.; Ober, Christopher K.

    2015-01-01

    Thin films of block copolymers are extremely attractive for nanofabrication because of their ability to form uniform and periodic nanoscale structures by microphase separation. One shortcoming of this approach is that to date the design of a desired equilibrium structure requires synthesis of a block copolymer de novo within the corresponding volume ratio of the blocks. In this work, we investigated solvent vapor annealing in supported thin films of poly(2-hydroxyethyl methacrylate)-block-poly(methyl methacrylate) [PHEMA-b-PMMA] by means of grazing incidence small angle X–ray scattering (GISAXS). A spin-coated thin film of lamellar block copolymer was solvent vapor annealed to induce microphase separation and improve the long-range order of the self-assembled pattern. Annealing in a mixture of solvent vapors using a controlled volume ratio of solvents (methanol, MeOH, and tetrahydrofuran, THF), which are chosen to be preferential for each block, enabled selective formation of ordered lamellae, gyroid, hexagonal or spherical morphologies from a single block copolymer with a fixed volume fraction. The selected microstructure was then kinetically trapped in the dry film by rapid drying. To our knowledge, this paper describes the first reported case where in-situ methods are used to study the transition of block copolymer films from one initial disordered morphology to four different ordered morphologies, covering much of the theoretical diblock copolymer phase diagram. PMID:26819574

  11. PDQ-8 reference manual (LWBR development program)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pfiefer, C J; Spitz, C J

    1978-05-01

    The PDQ-8 program is designed to solve the neutron diffusion, depletion problem in one, two, or three dimensions on the CDC-6600 and CDC-7600 computers. The three dimensional spatial calculation may be either explicit or discontinuous trial function synthesis. Up to five lethargy groups are permitted. The fast group treatment may be simplified P(3), and the thermal neutrons may be represented by a single group or a pair of overlapping groups. Adjoint, fixed source, one iteration, additive fixed source, eigenvalue, and boundary value calculations may be performed. The HARMONY system is used for cross section variation and generalized depletion chain solutions.more » The depletion is a combination gross block depletion for all nuclides as well as a fine block depletion for a specified subset of the nuclides. The geometries available include rectangular, cylindrical, spherical, hexagonal, and a very general quadrilateral geometry with diagonal interfaces. All geometries allow variable mesh in all dimensions. Various control searches as well as temperature and xenon feedbacks are provided. The synthesis spatial solution time is dependent on the number of trial functions used and the number of gross blocks. The PDQ-8 program is used at Bettis on a production basis for solving diffusion--depletion problems. The report describes the various features of the program and then separately describes the input required to utilize these features.« less

  12. [Treatment of calcaneal avulsion fractures with twinfix suture anchors fixation].

    PubMed

    Zhao, Bin-xiu; Wang, Kun-zheng; Wang, Chun-sheng; Xie, Yue; Dai, Zhi-tang; Liu, Gang; Liu, Wei-dong

    2011-06-01

    For the calcaneal avulsion fracture, the current method is more commonly used screws or Kirschner wire to fix fracture fragment. This article intended to explore the feasibility and clinical efficacy for the treatment of avulsion fractures with TwinFix suture anchors. From July 2007 to November 2010, 21 patients were reviewed, including 15 males and 6 females, ranging in age from 49 to 65 years,with a mean of 58.7 years. Twelve patients had nodules in the right heel and 9 patients had nodules in the left heel. All the patients had closed fractures. The typical preoperative symptoms of the patients included pain in the upper heel and weak in heel lift. Body examination results: palpable sense of bone rubbing in the back of the heel, and swelling in the heel. Surgery treatment with TwinFix suture anchors performed as follows : to fix TwinFix suture anchors into the calcaneal body, then to drill the fracture block, to make the double strand suture through the fracture holes, to knot the suture eachother to fix the block, and to use stitch to fix the remaining suture in the Achilles tendon in order to improve the block fixation. The criteria of the AOFAS Foot and Ankle Surgery by the United States Association of ankle-rear foot functional recovery was used to evaluate the Achilles tendon. Total average score was (95.5 +/- 3.12) points, including pain items of(38.5 +/- 2.18) points,the average score of functional items of (49.5 +/- 3.09) points,and power lines of 10 points in all patients. Twenty-one patients got an excellent result, 16 good and 5 poor. The methods of treatment for the calcaneal avulsion fractures with TwinFix suture anchors is a simple operation, and have excellent clinical effect, which is worthy of promotion.

  13. Intelligence/Electronic Warfare (IEW) Direction-Finding and Fix Estimation Analysis Report. Volume 2. Trailblazer

    DTIC Science & Technology

    1985-12-20

    Report) Approved for Public Disemination I 17. DISTRIBUTION STATEMENT (of the abstract entered In Block 20, It different from Report) I1. SUPPLEMENTARY...Continue an riverl. aid. It neceseary ind Idoni..•y by block number) Fix Estimation Statistical Assumptions, Error Budget, Unnodclcd Errors, Coding...llgedl i t Eh’ fI) t r !". 1 I ’ " r, tl 1: a Icr it h m hc ro ,, ] y zcd arc Csedil other Current TIV! Sysem ’ he report examines the underlying

  14. Evaluation of transversus abdominis plane block for renal transplant recipients - A meta-analysis and trial sequential analysis of published studies.

    PubMed

    Singh, Preet Mohinder; Borle, Anuradha; Makkar, Jeetinder Kaur; Trisha, Aanjan; Sinha, Aashish

    2018-01-01

    Patients undergoing renal transplant (RT) have altered drug/opioid pharmacokinetics. Transversus abdominis plane (TAP) block in renal transplant recipients has been recently evaluated for analgesic and opioid-sparing potential by many trials. The studies comparing TAP-block to conventional analgesic regimens for RT were searched. Comparisons were made for total opioids consumed (as morphine-equivalents) during the first postoperative 24-h (primary objective), intraoperative, and immediate-postoperative period. Pain scores and postoperative nausea-vomiting (PONV) were also evaluated. Trial sequential analysis (TSA) was used to quantify the strength of analysis. Ten-trials with 258 and 237 patients in control and TAP-block group, respectively, were included. TAP-block decreased the 24-h (reported in 9-trials) opioid consumption by 14.61 ± 4.34 mg (reduction by 42.7%, random-effects, P < 0.001, I 2 = 97.82%). Sample size of the present analysis (472) was well past the required "information-size" variable (396) as per the TSA for a power of 85%. Intraoperative opioid consumption also decreased by 2.06 ± 0.63 mg (reduction of 27.8%) (random effects, P < 0.001, I 2 = 98.84%). Pain scores with TAP-block were significantly lower in both early and delayed postoperative phase. Odds ratio for PONV without TAP block was 1.99 ± 1.05 (Fixed-effects, P = 0.04, I 2 = 0%). Publication bias was likely (Egger's test, X-intercept=7.89, P < 0.05). TAP-block significantly lowers the intraoperative and cumulative postoperative 24-h opioid consumption in RT recipients. Persistent and better pain control is achieved when TAP-Block is used. Benefits of TAP block extend beyond the analgesic actions alone as it also decreases the 24-h incidence of postoperative nausea vomiting as well. The technique of the block needs standardization for RT recipients.

  15. Liposomal bupivacaine versus interscalene nerve block for pain control after total shoulder arthroplasty: A systematic review and meta-analysis.

    PubMed

    Wang, Kun; Zhang, Hong-Xia

    2017-10-01

    To illustrate the efficacy liposomal bupivacaine versus interscalene nerve block for pain management after total shoulder arthroplasty. A systematic search was performed in Medline, PubMed, Embase, ScienceDirect and the Cochrane Library. Data on patients prepared for total shoulder arthroplasty in studies that compared liposomal bupivacaine versus interscalene nerve block were retrieved. The endpoints were the visual analogue scale (VAS) and opioid consumption. Fixed/random effect model was used according to the heterogeneity tested by I 2 statistic. Software of Stata 11.0 was used for pooling the final outcomes. Four randomized controlled trials (RCTs) including 510 patients met the inclusion criteria. The present meta-analysis indicated that there were no significant differences between groups in terms of VAS score at 12 h, 24 h, and 48 h (p > 0.05). No significant differences were found regarding to opioid consumption at postoperative 12 h, 24 h and 48 h (p > 0.05). Compared with interscalene nerve block, liposomal bupivacaine had comparative effectiveness on reducing both pain scores and opioid consumption. Higher quality RCTs are required for further research. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  16. Workstation-Based Simulation for Rapid Prototyping and Piloted Evaluation of Control System Designs

    NASA Technical Reports Server (NTRS)

    Mansur, M. Hossein; Colbourne, Jason D.; Chang, Yu-Kuang; Aiken, Edwin W. (Technical Monitor)

    1998-01-01

    The development and optimization of flight control systems for modem fixed- and rotary-. wing aircraft consume a significant portion of the overall time and cost of aircraft development. Substantial savings can be achieved if the time required to develop and flight test the control system, and the cost, is reduced. To bring about such reductions, software tools such as Matlab/Simulink are being used to readily implement block diagrams and rapidly evaluate the expected responses of the completed system. Moreover, tools such as CONDUIT (CONtrol Designer's Unified InTerface) have been developed that enable the controls engineers to optimize their control laws and ensure that all the relevant quantitative criteria are satisfied, all within a fully interactive, user friendly, unified software environment.

  17. Temporal prediction modulates the evaluative processing of "good" action feedback: An electrophysiological study.

    PubMed

    Kimura, Kenta; Kimura, Motohiro; Iwaki, Sunao

    2016-10-01

    The present study aimed to investigate whether or not the evaluative processing of action feedback can be modulated by temporal prediction. For this purpose, we examined the effects of the predictability of the timing of action feedback on an ERP effect that indexed the evaluative processing of action feedback, that is, an ERP effect that has been interpreted as a feedback-related negativity (FRN) elicited by "bad" action feedback or a reward positivity (RewP) elicited by "good" action feedback. In two types of experimental blocks, the participants performed a gambling task in which they chose one of two cards and received an action feedback that indicated monetary gain or loss. In fixed blocks, the time interval between the participant's choice and the onset of the action feedback was fixed at 0, 500, or 1,000 ms in separate blocks; thus, the timing of action feedback was predictable. In mixed blocks, the time interval was randomly chosen from the same three intervals with equal probability; thus, the timing was less predictable. The results showed that the FRN/RewP was smaller in mixed than fixed blocks for the 0-ms interval trial, whereas there was no difference between the two block types for the 500-ms and 1,000-ms interval trials. Interestingly, the smaller FRN/RewP was due to the modulation of gain ERPs rather than loss ERPs. These results suggest that temporal prediction can modulate the evaluative processing of action feedback, and particularly good feedback, such as that which indicates monetary gain. © 2016 Society for Psychophysiological Research.

  18. 49 CFR 231.2 - Hopper cars and high-side gondolas with fixed ends.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... car, except buffer block, brake shaft, brake wheel, brake step, or uncoupling lever shall extend to... knuckle when closed with coupler horn against the buffer block or end sill, and no other part of end of... outer face of buffer block. (2) Carriers are not required to make changes to secure additional end...

  19. Second-Degree Interatrial Block in Hemodialysis Patients

    PubMed Central

    Enriquez, Andres; D'Amato, Anna; de Luna, Antoni Bayes; Baranchuk, Adrian

    2015-01-01

    Interatrial conduction delays manifest as a prolonged P-wave duration on surface ECG and the term interatrial block (IAB) has been coined. They are usually fixed, but cases of intermittent IAB have been described, suggesting functional conduction block at the Bachmann bundle region. We report 2 cases of patients on chronic hemodialysis therapy presenting with intermittent IAB. PMID:25755895

  20. An evaluation of oral health-related quality of life in orthodontic patients treated with fixed and twin blocks appliances

    PubMed Central

    Alzoubi, Emad EM; Hariri, Racha; Mulligan, Kevin; Attard, Nikolai

    2017-01-01

    OBJECTIVE: To study the impact of orthodontic treatment on the quality of life in two patient groups, one treated with the twin block appliance and the other with fixed appliances. MATERIALS AND METHODS: Ninety-eight patients, aged between 10 and 16 years, were recruited in the fixed (20 males and 29 females) or functional (29 males and 20 females) treatment groups. The oral health-related quality of life (OHRQoL) was measured before treatment and followed up at the end of the treatment. The instrument used to measure OHRQoL was a modified self-administered short version of the English Oral Health Impact profile (OHIP-16[E]) questionnaire. RESULTS: OHRQoL worsened at the initial stages of the treatment. The overall score of OHRQoL reduced significantly at the end of the treatment in both groups. Both groups showed comparable improvements in OHRQoL as the treatment progressed (analysis of variance test P = 0.05). CONCLUSIONS: The OHRQoL patterns, during the treatment with fixed and twin block appliances, were very similar. This suggests that the functional appliance's impact on the QoL may be overestimates by clinicians. OHRQoL improved significantly with both fixed and functional appliances by the end of the treatment. The OHRQoL trends observed during the study can be communicated to patients and used to increase patients’ compliance since they are made aware of the whole treatment process. PMID:28546959

  1. Displays mounted on cutting blocks reduce the learning curve in navigated total knee arthroplasty.

    PubMed

    Schnurr, Christoph; Eysel, Peer; König, Dietmar Pierre

    2011-01-01

    The use of computer navigation in total knee arthroplasty (TKA) improves the implant alignment but increases the operation time. Studies have shown that the operation time is further prolonged due to the surgeon's learning curve, and longer operation times have been associated with higher morbidity risks. It has been our hypothesis that an improvement in the human-machine interface might reduce the time required during the learning curve. Accordingly, we asked whether the use of navigation devices with a display fixed on the surgical instruments would reduce the operation time in navigated TKAs performed by navigation beginners. Thirty medical students were randomized and used two navigation devices in rotation: these were the Kolibri® device with an external display and the Dash® device with a display that was fixed on the cutting blocks. The time for adjustment of the tibial and femoral cutting blocks on knee models while using these devices was measured. A significant time reduction was demonstration when the Dash® device was used: The time reduction was 21% for the tibial block (p = 0.007), 40% for the femoral block (p < 0.001), and 32% for the whole procedure (p < 0.001). The integrated display, fixed on surgical instruments in a manner similar to a spirit level, seems to be more user-friendly for navigation beginners. Hence, unproductive time losses during the learning curve may be diminished.

  2. Fail-fixed servovalve with positive fluid feedback

    NASA Technical Reports Server (NTRS)

    Kast, Howard B. (Inventor)

    1984-01-01

    The servovalve includes a primary jet of fluid. A variable control signal is adapted to vary the angular position of the primary jet from its maximum recovery position. A first fluid path is adapted to supply fluid to a servopiston at a variable pressure determined at least in part by the control signal. A second fluid path is adapted to receive a predetermined portion of the primary jet fluid when the control signal reaches a predetermined value. The second fluid path terminates in the vicinity of the primary jet and is adapted to direct a secondary jet of fluid at the primary jet to deflect the primary jet toward the input orifice of the second fluid path. The resultant positive fluid feedback in the second fluid path causes the primary jet to latch in a first angular position relative to the maximum recovery position when the control signal reaches a predetermined value. The servovalve may further include a means to discharge the fluid and a means to block the first fluid path to the servopiston when the control signal falls below a second predetermined value. A method of operating a fail-fixed servovalve is also described.

  3. How to push a block along a wall

    NASA Technical Reports Server (NTRS)

    Mason, Matthew T.

    1989-01-01

    Some robot tasks require manipulation of objects that may be touching other fixed objects. The effects of friction and kinematic constraint must be anticipated, and may even be exploited to accomplish the task. An example task, a dynamic analysis, and appropriate effector motions are presented. The goal is to move a rectangular block along a wall, so that one side of the block maintains contact with the wall. Two solutions that push the block along the wall are discussed.

  4. Evaluation of formalin-fixed paraffin-embedded tissues from vaccine site-associated sarcomas of cats for papillomavirus DNA and antigen.

    PubMed

    Kidney, B A; Haines, D M; Ellis, J A; Burnham, M L; Teifke, J P; Czerwinski, G; Jackson, M L

    2001-06-01

    To determine whether vaccine site-associated sarcomas (VSS) from cats contain papillomavirus antigen or DNA. 50 formalin-fixed paraffin-embedded tissue blocks of VSS from cats. Sections from each tissue block were evaluated for papillomavirus antigen by use of an avidin-biotin-complex immunohistochemical staining method, using rabbit anti-bovine papillomavirus type-1 antibody. The DNA was extracted from sections of each tissue block, and polymerase chain reaction assays were performed, using primers designed to amplify regions of the E5 gene of bovine papillomavirus and consensus primers designed to amplify a region of the L1 gene of animal papillomaviruses. Sections from 20 of the tissue blocks were evaluated by use of nonradioactive in situ hybridization for bovine papillomavirus DNA. Papillomavirus antigen and DNA were not detected in any of the VSS. Results suggest that papillomaviruses likely do not have any direct involvement in the pathogenesis of VSS in cats.

  5. Variable delivery, fixed displacement pump

    DOEpatents

    Sommars, Mark F.

    2001-01-01

    A variable delivery, fixed displacement pump comprises a plurality of pistons reciprocated within corresponding cylinders in a cylinder block. The pistons are reciprocated by rotation of a fixed angle swash plate connected to the pistons. The pistons and cylinders cooperate to define a plurality of fluid compression chambers each have a delivery outlet. A vent port is provided from each fluid compression chamber to vent fluid therefrom during at least a portion of the reciprocal stroke of the piston. Each piston and cylinder combination cooperates to close the associated vent port during another portion of the reciprocal stroke so that fluid is then pumped through the associated delivery outlet. The delivery rate of the pump is varied by adjusting the axial position of the swash plate relative to the cylinder block, which varies the duration of the piston stroke during which the vent port is closed.

  6. Novel modes and adaptive block scanning order for intra prediction in AV1

    NASA Astrophysics Data System (ADS)

    Hadar, Ofer; Shleifer, Ariel; Mukherjee, Debargha; Joshi, Urvang; Mazar, Itai; Yuzvinsky, Michael; Tavor, Nitzan; Itzhak, Nati; Birman, Raz

    2017-09-01

    The demand for streaming video content is on the rise and growing exponentially. Networks bandwidth is very costly and therefore there is a constant effort to improve video compression rates and enable the sending of reduced data volumes while retaining quality of experience (QoE). One basic feature that utilizes the spatial correlation of pixels for video compression is Intra-Prediction, which determines the codec's compression efficiency. Intra prediction enables significant reduction of the Intra-Frame (I frame) size and, therefore, contributes to efficient exploitation of bandwidth. In this presentation, we propose new Intra-Prediction algorithms that improve the AV1 prediction model and provide better compression ratios. Two (2) types of methods are considered: )1( New scanning order method that maximizes spatial correlation in order to reduce prediction error; and )2( New Intra-Prediction modes implementation in AVI. Modern video coding standards, including AVI codec, utilize fixed scan orders in processing blocks during intra coding. The fixed scan orders typically result in residual blocks with high prediction error mainly in blocks with edges. This means that the fixed scan orders cannot fully exploit the content-adaptive spatial correlations between adjacent blocks, thus the bitrate after compression tends to be large. To reduce the bitrate induced by inaccurate intra prediction, the proposed approach adaptively chooses the scanning order of blocks according to criteria of firstly predicting blocks with maximum number of surrounding, already Inter-Predicted blocks. Using the modified scanning order method and the new modes has reduced the MSE by up to five (5) times when compared to conventional TM mode / Raster scan and up to two (2) times when compared to conventional CALIC mode / Raster scan, depending on the image characteristics (which determines the percentage of blocks predicted with Inter-Prediction, which in turn impacts the efficiency of the new scanning method). For the same cases, the PSNR was shown to improve by up to 7.4dB and up to 4 dB, respectively. The new modes have yielded 5% improvement in BD-Rate over traditionally used modes, when run on K-Frame, which is expected to yield 1% of overall improvement.

  7. The effects of age-in-block on RNA-seq analysis of archival formalin-fixed paraffin-embedded (FFPE) samples

    EPA Science Inventory

    Archival samples represent a vast resource for identification of chemical and pharmaceutical targets. Previous use of formalin-fixed paraffin-embedded (FFPE) samples has been limited due to changes in RNA introduced by fixation and embedding procedures. Recent advances in RNA-seq...

  8. Evaluation of formalin-fixed paraffin-embedded tissues from vaccine site-associated sarcomas of cats for polyomavirus DNA and antigen.

    PubMed

    Kidney, B A; Haines, D M; Ellis, J A; Burnham, M; Jackson, M L

    2001-06-01

    To determine whether vaccine site-associated sarcomas (VSS) from cats contain polyomavirus antigen or DNA. 50 formalin-fixed paraffin-embedded tissue blocks of VSS from cats. Sections from each tissue block were evaluated for polyomavirus antigen by use of an avidin-biotin-complex immunohistochemical staining method, using rabbit anti-murine polyomavirus polyclonal antiserum as the primary antibody. The DNA was extracted from sections of each tissue block, and a polymerase chain reaction assay was performed, using primers designed to amplify regions of the bovine polyomavirus genome and consensus polyomavirus primers designed to detect unknown polyomaviruses. Polyomavirus antigen and DNA were not detected in any of the VSS. Results suggest that polyomaviruses likely do not have any direct involvement in the pathogenesis of VSS in cats.

  9. 47 CFR 8.5 - No blocking.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... FEDERAL COMMUNICATIONS COMMISSION GENERAL PRESERVING THE OPEN INTERNET § 8.5 No blocking. (a) A person engaged in the provision of fixed broadband Internet access service, insofar as such person is so engaged... network management. (b) A person engaged in the provision of mobile broadband Internet access service...

  10. 47 CFR 8.5 - No blocking.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... FEDERAL COMMUNICATIONS COMMISSION GENERAL PRESERVING THE OPEN INTERNET § 8.5 No blocking. (a) A person engaged in the provision of fixed broadband Internet access service, insofar as such person is so engaged... network management. (b) A person engaged in the provision of mobile broadband Internet access service...

  11. 47 CFR 8.5 - No blocking.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... FEDERAL COMMUNICATIONS COMMISSION GENERAL PRESERVING THE OPEN INTERNET § 8.5 No blocking. (a) A person engaged in the provision of fixed broadband Internet access service, insofar as such person is so engaged... network management. (b) A person engaged in the provision of mobile broadband Internet access service...

  12. 47 CFR 8.5 - No Blocking.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... FEDERAL COMMUNICATIONS COMMISSION GENERAL PRESERVING THE OPEN INTERNET § 8.5 No Blocking. (a) A person engaged in the provision of fixed broadband Internet access service, insofar as such person is so engaged... network management. (b) A person engaged in the provision of mobile broadband Internet access service...

  13. Spectral characteristics of speech with fixed jaw displacements

    NASA Astrophysics Data System (ADS)

    Solomon, Nancy P.; Makashay, Matthew J.; Munson, Benjamin

    2004-05-01

    During speech, movements of the mandible and the tongue are interdependent. For some research purposes, the mandible may be constrained to ensure independent tongue motion. To examine specific spectral characteristics of speech with different jaw positions, ten normal adults produced sentences with multiple instances of /t/, /s/, /squflg/, /i/, /ai/, and /squflgi/. Talkers produced stimuli with the jaw free to vary, and while gently biting on 2- and 5-mm bite blocks unilaterally. Spectral moments of /s/ and /squflg/ frication and /t/ bursts differed such that mean spectral energy decreased, and diffuseness and skewness increased with bite blocks. The specific size of the bite block had minimal effect on these results, which were most consistent for /s/. Formant analysis for the vocoids revealed lower F2 frequency in /i/ and at the end of the transition in /ai/ when bite blocks were used; F2 slope for diphthongs was not sensitive to differences in jaw position. Two potential explanations for these results involve the physical presence of the bite blocks in the lateral oral cavity, and the oromotor system's ability to compensate for fixed jaw displacements. [Work supported by NIDCD R03-DC06096.

  14. Universality for 1d Random Band Matrices: Sigma-Model Approximation

    NASA Astrophysics Data System (ADS)

    Shcherbina, Mariya; Shcherbina, Tatyana

    2018-02-01

    The paper continues the development of the rigorous supersymmetric transfer matrix approach to the random band matrices started in (J Stat Phys 164:1233-1260, 2016; Commun Math Phys 351:1009-1044, 2017). We consider random Hermitian block band matrices consisting of W× W random Gaussian blocks (parametrized by j,k \\in Λ =[1,n]^d\\cap Z^d ) with a fixed entry's variance J_{jk}=δ _{j,k}W^{-1}+β Δ _{j,k}W^{-2} , β >0 in each block. Taking the limit W→ ∞ with fixed n and β , we derive the sigma-model approximation of the second correlation function similar to Efetov's one. Then, considering the limit β , n→ ∞, we prove that in the dimension d=1 the behaviour of the sigma-model approximation in the bulk of the spectrum, as β ≫ n , is determined by the classical Wigner-Dyson statistics.

  15. Uav Photogrammetry: Block Triangulation Comparisons

    NASA Astrophysics Data System (ADS)

    Gini, R.; Pagliari, D.; Passoni, D.; Pinto, L.; Sona, G.; Dosso, P.

    2013-08-01

    UAVs systems represent a flexible technology able to collect a big amount of high resolution information, both for metric and interpretation uses. In the frame of experimental tests carried out at Dept. ICA of Politecnico di Milano to validate vector-sensor systems and to assess metric accuracies of images acquired by UAVs, a block of photos taken by a fixed wing system is triangulated with several software. The test field is a rural area included in an Italian Park ("Parco Adda Nord"), useful to study flight and imagery performances on buildings, roads, cultivated and uncultivated vegetation. The UAV SenseFly, equipped with a camera Canon Ixus 220HS, flew autonomously over the area at a height of 130 m yielding a block of 49 images divided in 5 strips. Sixteen pre-signalized Ground Control Points, surveyed in the area through GPS (NRTK survey), allowed the referencing of the block and accuracy analyses. Approximate values for exterior orientation parameters (positions and attitudes) were recorded by the flight control system. The block was processed with several software: Erdas-LPS, EyeDEA (Univ. of Parma), Agisoft Photoscan, Pix4UAV, in assisted or automatic way. Results comparisons are given in terms of differences among digital surface models, differences in orientation parameters and accuracies, when available. Moreover, image and ground point coordinates obtained by the various software were independently used as initial values in a comparative adjustment made by scientific in-house software, which can apply constraints to evaluate the effectiveness of different methods of point extraction and accuracies on ground check points.

  16. Assessment of the RIVET fixation system for cranioplasty using the pull-out technique.

    PubMed

    Sakamoto, Yoshiaki; Minabe, Toshiharu; Kato, Tatsuya; Kishi, Kazuo

    2015-03-01

    Cranioplasty using custom-made hydroxyapatite (HAP) ceramic implants is a common procedure to repair skull defects. However, commercially available titanium screws are only minimally stabilized due to characteristic brittleness. We developed the RIVET technique which involves fixing a bioabsorbable plate atop a HAP block using bioabsorbable screws extending beyond both layers, and evaluated fixation strength using the pull-out test and microtomography. Three experimental conditions were compared: a non-RIVET group, RIVET group, and dry skull control group. Pull-out strength significantly differed across groups (non-RIVET group, 1.33 ± 1.21 kgf; RIVET group, 4.46 ± 0.84 kgf; and control group, 6.99 ± 1.14 kgf, P < 0.01). Microtomography of the dry skull control group revealed thread grooves fitted to the screws. The non-RIVET and RIVET groups presented fewer thread grooves than the control group, and the screws did not fit perfectly to the HAP block. However, fixation in the RIVET group was more stable, as the rivet was firmly lodged into the implant. In conclusion, by melting and creating the rivet, pull-out strength can be increased and rigid stabilization of HAP can be obtained. This technique uses commercially available absorbable plate and screws, and thus can be used widely in clinical applications involving HAP blocks with different porosities and thicknesses. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  17. Wideband, mobile networking technologies

    NASA Astrophysics Data System (ADS)

    Hyer, Kevin L.; Bowen, Douglas G.; Pulsipher, Dennis C.

    2005-05-01

    Ubiquitous communications will be the next era in the evolving communications revolution. From the human perspective, access to information will be instantaneous and provide a revolution in services available to both the consumer and the warfighter. Services will be from the mundane - anytime, anywhere access to any movie ever made - to the vital - reliable and immediate access to the analyzed real-time video from the multi-spectral sensors scanning for snipers in the next block. In the former example, the services rely on a fixed infrastructure of networking devices housed in controlled environments and coupled to fixed terrestrial fiber backbones - in the latter, the services are derived from an agile and highly mobile ad-hoc backbone established in a matter of minutes by size, weight, and power-constrained platforms. This network must mitigate significant changes in the transmission media caused by millisecond-scale atmospheric temperature variations, the deployment of smoke, or the drifting of a cloud. It must mitigate against structural obscurations, jet wash, or incapacitation of a node. To maintain vital connectivity, the mobile backbone must be predictive and self-healing on both near-real-time and real-time time scales. The nodes of this network must be reconfigurable to mitigate intentional and environmental jammers, block attackers, and alleviate interoperability concerns caused by changing standards. The nodes must support multi-access of disparate waveform and protocols.

  18. Suspension System Provides Independent Translation And Rotation

    NASA Technical Reports Server (NTRS)

    Heeg, Jennifer

    1994-01-01

    Spring suspension provides one translational and one rotational degree of freedom. Suspension used to provide for pitching and plunging movements of airfoil in wind tunnel. Translational freedom provided by two thin, flat steel spring tines, clamped at one end to stationary block fixed to ceiling of wind tunnel, and clamped to movable block at other end.

  19. Degenerate operators and the 1/c expansion: Lorentzian resummations, high order computations, and super-Virasoro blocks

    DOE PAGES

    Chen, Hongbin; Fitzpatrick, A. Liam; Kaplan, Jared; ...

    2017-03-30

    Here, one can obtain exact information about Virasoro conformal blocks by analytically continuing the correlators of degenerate operators. We argued in recent work that this technique can be used to explicitly resolve information loss problems in AdS 3/CFT 2. In this paper we use the technique to perform calculations in the small 1/c ∝ GN expansion: (1) we prove the all-orders resummation of logarithmic factors ∝1/clog z in the Lorentzian regime, demonstrating that 1/c corrections directly shift Lyapunov exponents associated with chaos, as claimed in prior work, (2) we perform another all-orders resummation in the limit of large c withmore » fixed cz, interpolating between the early onset of chaos and late time behavior, (3) we explicitly compute the Virasoro vacuum block to order 1/c 2 and 1/c 3 with external dimensions fixed, corresponding to 2 and 3 loop calculations in AdS 3, and (4) we derive the heavy-light vacuum blocks in theories with N = 1, 2 superconformal symmetry.« less

  20. Degenerate operators and the 1/c expansion: Lorentzian resummations, high order computations, and super-Virasoro blocks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Hongbin; Fitzpatrick, A. Liam; Kaplan, Jared

    Here, one can obtain exact information about Virasoro conformal blocks by analytically continuing the correlators of degenerate operators. We argued in recent work that this technique can be used to explicitly resolve information loss problems in AdS 3/CFT 2. In this paper we use the technique to perform calculations in the small 1/c ∝ GN expansion: (1) we prove the all-orders resummation of logarithmic factors ∝1/clog z in the Lorentzian regime, demonstrating that 1/c corrections directly shift Lyapunov exponents associated with chaos, as claimed in prior work, (2) we perform another all-orders resummation in the limit of large c withmore » fixed cz, interpolating between the early onset of chaos and late time behavior, (3) we explicitly compute the Virasoro vacuum block to order 1/c 2 and 1/c 3 with external dimensions fixed, corresponding to 2 and 3 loop calculations in AdS 3, and (4) we derive the heavy-light vacuum blocks in theories with N = 1, 2 superconformal symmetry.« less

  1. Mouse hepatitis virus immunofluorescence in formalin- or Bouin's-fixed tissues using trypsin digestion.

    PubMed

    Brownstein, D G; Barthold, S W

    1982-02-01

    Mouse hepatitis viral antigens were demonstrated by immunofluorescence in formalin- and Bouin's-fixed tissues processed routinely for histopathology followed by partial digestion with trypsin. Staining was superior in tissues fixed in formalin and was not diminished in tissue sections from paraffin blocks stored at room temperature as long as 2 years. The relative ease of this procedure and the commercial availability of reagents makes this a useful technique for the definitive diagnosis of mouse hepatitis virus infection.

  2. Risky Choice in Pigeons: Preference for Amount Variability Using a Token-Reinforcement System

    ERIC Educational Resources Information Center

    Lagorio, Carla H.; Hackenberg, Timothy D.

    2012-01-01

    Pigeons were given repeated choices between variable and fixed numbers of token reinforcers (stimulus lamps arrayed above the response keys), with each earned token exchangeable for food. The number of tokens provided by the fixed-amount option remained constant within blocks of sessions, but varied parametrically across phases, assuming values of…

  3. RCL2, a potential formalin substitute for tissue fixation in routine pathological specimens.

    PubMed

    Masir, Noraidah; Ghoddoosi, Mahdiieh; Mansor, Suhada; Abdul-Rahman, Faridah; Florence, Chandramaya S; Mohamed-Ismail, Nor Azlin; Tamby, Mohammad-Rafaee; Md-Latar, Nani Harlina

    2012-04-01

    To investigate RCL2 as a fixative for tissue fixation in routine histopathological examination and to assess tissue suitability for ancillary investigations.   Forty-nine samples from 36 fresh specimens were cut into three equal pieces and fixed in RCL2 diluted in 100% ethanol, RCL2 in 95% ethanol, or neutral buffered formalin as control. Suitability for microtomy, quality of histomorphology, histochemistry, immunohistochemistry, fluorescent and silver in-situ hybridization analysis and extracted genomic DNA were assessed. Microtomy was straightforward in most tissue blocks, but there was difficulty in cutting in approximately a quarter of samples, which required careful handling by an experienced technician. There were no significant differences in tissue morphology between RCL2- and formalin-fixed tissues (P=0.08). Generally, the quality of histochemical staining, immunohistochemistry and in-situ hybridization were comparable to that of formalin-fixed tissues. Inconsistent immunoreactivity was noted, however, with antibodies against pan-cytokeratin and progesterone receptor. Genomic DNA concentration was higher in RCL2-fixed tissues. Using RCL2 diluted in 95% ethanol did not affect fixation quality. RCL2 is a potential formalin substitute suitable as a fixative for use in routine histopathological examination; however, difficulty in microtomy and occasional discrepancies in immunohistochemical reactivity require further optimization of the methodology. © 2012 Blackwell Publishing Ltd.

  4. Validation of 31 of the most commonly used immunohistochemical antibodies in cytology prepared using the Cellient(®) automated cell block system.

    PubMed

    Montgomery, Eric; Gao, Chen; de Luca, Julie; Bower, Jessie; Attwood, Kristropher; Ylagan, Lourdes

    2014-12-01

    The Cellient(®) cell block system has become available as an alternative, partially automated method to create cell blocks in cytology. We sought to show a validation method for immunohistochemical (IHC) staining on the Cellient cell block system (CCB) in comparison with the formalin fixed paraffin embedded traditional cell block (TCB). Immunohistochemical staining was performed using 31 antibodies on 38 patient samples for a total of 326 slides. Split samples were processed using both methods by following the Cellient(®) manufacturer's recommendations for the Cellient cell block (CCB) and the Histogel method for preparing the traditional cell block (TCB). Interpretation was performed by three pathologists and two cytotechnologists. Immunohistochemical stains were scored as: 0/1+ (negative) and 2/3+ (positive). Inter-rater agreement for each antibody was evaluated for CCB and TCB, as well as the intra-rater agreement between TCB and CCB between observers. Interobserver staining concordance for the TCB was obtained with statistical significance (P < 0.05) in 24 of 31 antibodies. Interobserver staining concordance for the CCB was obtained with statistical significance in 27 of 31 antibodies. Intra-observer staining concordance between TCB and CCB was obtained with statistical significance in 24 of 31 antibodies tested. In conclusions, immunohistochemical stains on cytologic specimens processed by the Cellient system are reliable and concordant with stains performed on the same split samples processed via a formalin fixed-paraffin embedded (FFPE) block. The Cellient system is a welcome adjunct to cytology work-flow by producing cell block material of sufficient quality to allow the use of routine IHC. © 2014 Wiley Periodicals, Inc.

  5. Multi-ligament instability after early dislocation of a primary total knee replacement - case report.

    PubMed

    Sisak, Krisztian; Lloyd, John; Fiddian, Nick

    2011-01-01

    Peripheral nerve blocks have found increased popularity in providing prolonged post-operative analgesia following total knee replacement surgery. They generally provide effective analgesia with fewer complications than epidurals. This report describes an acute low-energy knee dislocation after a well balanced, fixed bearing, cruciate-retaining primary total knee replacement performed under a spinal anaesthetic with combined complimentary femoral and sciatic nerve blocks. The dislocation was not accompanied by neurovascular compromise. Due to the subsequent instability and injury to both collaterals, the posterior cruciate ligament and posterolateral corner structures, the knee was treated with a rotating-hinge revision total knee replacement. The dislocation occurred whilst the peripheral nerve blocks (PNB) were still working. We review our incidence of PNB related complications and conclude that PNB remain a safe and effective analgesia for total knee replacements. However, we advocate that ward staff and patients should be sufficiently educated to ensure that unaided post-operative mobilisation is prevented until such a time that patients have regained complete voluntary muscle control. Copyright © 2009 Elsevier B.V. All rights reserved.

  6. Systems and methods for dismantling a nuclear reactor

    DOEpatents

    Heim, Robert R; Adams, Scott Ryan; Cole, Matthew Denver; Kirby, William E; Linnebur, Paul Damon

    2014-10-28

    Systems and methods for dismantling a nuclear reactor are described. In one aspect the system includes a remotely controlled heavy manipulator ("manipulator") operatively coupled to a support structure, and a control station in a non-contaminated portion of a workspace. The support structure provides the manipulator with top down access into a bioshield of a nuclear reactor. At least one computing device in the control station provides remote control to perform operations including: (a) dismantling, using the manipulator, a graphite moderator, concrete walls, and a ceiling of the bioshield, the manipulator being provided with automated access to all internal portions of the bioshield; (b) loading, using the manipulator, contaminated graphite blocks from the graphite core and other components from the bioshield into one or more waste containers; and (c) dispersing, using the manipulator, dust suppression and contamination fixing spray to contaminated matter.

  7. Growth-dissolution-regrowth transitions of Fe3O4 nanoparticles as building blocks for 3D magnetic nanoparticle clusters under hydrothermal conditions.

    PubMed

    Lin, Mouhong; Huang, Haoliang; Liu, Zuotao; Liu, Yingju; Ge, Junbin; Fang, Yueping

    2013-12-10

    Magnetic nanoparticle clusters (MNCs) are a class of secondary structural materials that comprise chemically defined nanoparticles assembled into clusters of defined size. Herein, MNCs are fabricated through a one-pot solvothermal reaction featuring self-limiting assembly of building blocks and the controlled reorganization process. Such growth-dissolution-regrowth fabrication mechanism overcomes some limitations of conventional solvothermal fabrication methods with regard to restricted available feature size and structural complexity, which can be extended to other oxides (as long as one can be chelated by EDTA-2Na). Based on this method, the nanoparticle size of MNCs is tuned between 6.8 and 31.2 nm at a fixed cluster diameter of 120 nm, wherein the critical size for superparamagnetic-ferromagnetic transition is estimated from 13.5 to 15.7 nm. Control over the nature and secondary structure of MNCs gives an excellent model system to understand the nanoparticle size-dependent magnetic properties of MNCs. MNCs have potential applications in many different areas, while this work evaluates their cytotoxicity and Pb(2+) adsorption capacity as initial application study.

  8. Quantitative measurement of channel-block hydraulic interactions by experimental saturation of a large, natural, fissured rock mass.

    PubMed

    Guglielmi, Y; Mudry, J

    2001-01-01

    The hydrodynamic behavior of fissured media relies on the relationships between a few very conductive fractures (channels) and the remaining low-conductivity fractures and matrix (blocks). We made a quantitative measurement of those relationships and their effect on water drainage and storage in a 19,000 m3 natural reservoir consisting of karstified limestones. This reservoir was artificially saturated with water by closing a water gate on the main outlet during a varying time (delta t) fixed by the operator. The water gate was completely or partly closed until the water pressure reached a particular specified value. If the water gate was left completely closed long enough, the water pressure was fixed by the elevation of temporary outlets at the site boundaries. The water elevation within the reservoir was monitored by means of pressure cells located on single fractures representative of the bedding plane and the two families of fractures of the massif network. The comparison of pressure variations with the network geometry allows us to identify a typical double permeability characterized by a few very conductive channels along 10 vertical faults. These channels limit blocks consisting of low-conductivity bedding planes and a rather impervious matrix. Depending on the closure interval, delta t, of the water gate, the total volume of water stored in the reservoir can vary from 0.8 m3 (delta t = 5 minutes) to 18.6 m3 (delta t = 2 days). Such a variance of storage versus closure time is explained by the reservoir's double permeability that is characterized by blocks that saturate much more slowly than channels. If plotted versus time, this injected volume fits a power relationship, according to the saturation state of the blocks. In less than 34 minutes, storage is close to zero in the blocks and to 1.6 to 2 m3 in the channels. For closing times shorter than 1 hour, only 1% of the volume that flows in the channels is stored into the blocks. Depending on the water pressure and for a given delta t = 3000 minutes, the volume of water stored is controlled by the geometry of the joint network and of the aquifer boundaries. Such an experiment shows that the flow is concentrated in about 10% of the fractured network (channels). The water storage that takes place in the 90% remaining fractures (blocks) depends mainly on time during which pressure remains high into the 10% channels. The accurate modeling of such typical double-permeability media needs a careful study of the geometry of the channels whose narrowings modify the flow and induce dam effects that maintain a high pressure gradient with surrounding blocks.

  9. V-type multicylinder internal combustion engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsuboi, M.

    1986-05-20

    A V-type multicylinder internal combustion engine is described for vehicles comprising front and rear cylinder blocks arrayed in V shape longitudinally of a vehicle body, front and rear cylinder heads fixed on each cylinder block, pistons sliding in the cylinder blocks, a crank and transmission case formed uniformly on the cylinder blocks, a crankshaft extending transversely of the vehicle body borne rotatably on both side walls of the crank and transmission case at journals on both sides, the crankshaft being coupled to the pistons at a crank pin through connecting rods and provided with front and rear driving sprockets, frontmore » and rear cam shafts mounted rotatably on the cylinder heads with driven sprockets fixed thereon, a front timing chain laid between the front driving sprocket and the front driven sprocket and constituting together with the front driving and driven sprockets a front cam driving means, a rear timing chain laid between the rear driving sprocket and the rear driven sprocket and constituting together with the rear driving and driven sprockets a rear cam driving means, and a speed change gear coupled to the crankshaft by way of a primary reduction gear and a clutch.« less

  10. Effect of vital tooth bleaching on solubility and roughness of dental cements.

    PubMed

    Londono, Jimmy; Abreu, Amara; Nelson, Steve; Hernandez, Jorge; Torres, Carlos; Mettenburg, Donald; Looney, Stephen; Rueggeberg, Frederick

    2009-09-01

    Vital tooth bleaching may affect properties of dental cements used for fixed prostheses. The purpose of this study was to examine the effect of a combined in-office and at-home bleaching regimen on changes in surface roughness and depth loss of a variety of commercially available dental cements. Five cement classifications were tested: glass ionomer, resin-modified glass ionomer, resin,self-adhesive resin cement, and zinc phosphate. Cements were placed in multiple wells in plastic blocks. After setting,the surface profile of each block was determined, and average roughness and vertical height of cement surface from the specimen holder were recorded. Blocks were water stored (control) or subjected to in-office and at-home bleaching(n=12). Surfaces were rescanned and pre- and posttest parameter changes were calculated. Statistical analysis consisted of Mann-Whitney-Wilcoxon Rank Sum and Student t tests applied to control and bleaching parameterc hanges within the same cements. A family-wise alpha of .05 was maintained by using a Bonferroni-adjusted level of significance preset to .01 per test. Zinc phosphate showed the only significant depth increase (P=.004) from bleaching: 0.9 +/- 0.7 microm deeper than the water-control group. Only resin-modified glass ionomer showed a significant (P=.004) increase in roughness from bleaching; values increased by 0.05 +/- 0.03 microm over the water-control group. In-office and at-home bleaching significantly increased depth loss of zinc phosphate and increased resinmodified glass ionomer roughness. However, the absolute values of differences observed, as compared to the wateronly control, were considered to be clinically insignificant. (J Prosthet Dent 2009;102:148-154)

  11. Development of hydrolysis probe-based real-time PCR for identification of virulent gene targets of Burkholderia pseudomallei and B. mallei--a retrospective study on archival cases of service members with melioidosis and glanders.

    PubMed

    Zhang, Binxue; Wear, Douglas J; Kim, H S; Weina, Peter; Stojadinovic, Alexander; Izadjoo, Mina

    2012-02-01

    Burkholderia pseudomallei and B. mallei are two highly pathogenic bacteria responsible for melioidosis and glanders, respectively. Our laboratory developed hydrolysis probe-based real-time polymerase chain reaction assays targeting type three secretion system (TTS) and transposase family protein (TFP) of B. pseudomallei and B. malli, respectively. The assays were validated for target specificity, amplification sensitivity, and reproducibility. A bacterial DNA panel, composed of B. pseudomallei (13 strains), B. mallei (11 strains), Burkholderia species close neighbors (5 strains), and other bacterial species (17 strains), was prepared for specificity testing. Reference DNAs from B. pseudomallei and B. mallei bacterial cultures were used as controls for amplification, limit of detection, and reproducibility testing. The two TaqMan assays, Bp-TTS 1 and Bm-TFP, were optimized and applied in a retrospective study of archived cases from the Armed Forces Institute of Pathology. We tested 10 formalin-fixed paraffin-embedded blocks originally from autopsy specimens of patients who died of melioidosis or glanders during or after overseas tours in 1960s. Polymerase chain reaction results confirmed that DNA samples from formalin-fixed paraffin-embedded blocks of eight patients with melioidosis were positive for Bp-TTS 1 target and two patients with glanders were positive for Bm-TFP target.

  12. Directional filtering for block recovery using wavelet features

    NASA Astrophysics Data System (ADS)

    Hyun, Seung H.; Eom, Il K.; Kim, Yoo S.

    2005-07-01

    When images compressed with block-based compression techniques are transmitted over a noisy channel, unexpected block losses occur. Conventional methods that do not consider edge directions can cause blocked blurring artifacts. In this paper, we present a post-processing-based block recovery scheme using Haar wavelet features. The adaptive selection of neighboring blocks is performed based on the energy of wavelet subbands (EWS) and difference between DC values (DDC). The lost blocks are recovered by linear interpolation in the spatial domain using selected blocks. The method using only EWS performs well for horizontal and vertical edges, but not as well for diagonal edges. Conversely, only using DDC performs well for diagonal edges with the exception of line- or roof-type edge profiles. Therefore, we combine EWS and DDC for better results. The proposed directional recovery method is effective for the strong edge because exploit the varying neighboring blocks adaptively according to the edges and the directional information in the image. The proposed method outperforms the previous methods that used only fixed blocks.

  13. Memory guidance in distractor suppression is governed by the availability of cognitive control.

    PubMed

    Wen, Wen; Hou, Yin; Li, Sheng

    2018-03-26

    Information stored in the memory systems can affect visual search. Previous studies have shown that holding the to-be-ignored features of distractors in working memory (WM) could accelerate target selection. However, such facilitation effect was only observed when the cued to-be-ignored features remained unchanged within an experimental block (i.e., the fixed cue condition). No search benefit was obtained if the to-be-ignored features varied from trial to trial (i.e., the varied cue condition). In the present study, we conducted three behavioral experiments to investigate whether the WM and long-term memory (LTM) representations of the to-be-ignored features could facilitate visual search in the fixed cue (Experiment 1) and varied cue (Experiments 2 and 3) conditions. Given the importance of the processing time of cognitive control in distractor suppression, we divided visual search trials into five quintiles based on their reaction times (RTs) and examined the temporal characteristics of the suppression effect. Results showed that both the WM and LTM representations of the to-be-ignored features could facilitate distractor suppression in the fixed cue condition, and the facilitation effects were evident across the quintiles in the RT distribution. However, in the varied cue condition, the RT benefits of the WM-matched distractors occurred only in the trials with the longest RTs, whereas no advantage of the LTM-matched distractors was observed. These results suggest that the effective WM-guided distractor suppression depends on the availability of cognitive control and the LTM-guided suppression occurs only if sufficient WM resource is accessible by LTM reactivation.

  14. Proteomic analysis of formalin-fixed paraffin-embedded renal tissue samples by label-free MS: assessment of overall technical variability and the impact of block age.

    PubMed

    Craven, Rachel A; Cairns, David A; Zougman, Alexandre; Harnden, Patricia; Selby, Peter J; Banks, Rosamonde E

    2013-04-01

    Protein profiling of formalin-fixed paraffin-embedded (FFPE) tissues has enormous potential for the discovery and validation of disease biomarkers. The aim of this study was to systematically characterize the effect of length of time of storage of such tissue blocks in pathology archives on the quality of data produced using label-free MS. Normal kidney and clear cell renal cell carcinoma tissues routinely collected up to 10 years prior to analysis were profiled using LC-MS/MS and the data analyzed using MaxQuant. Protein identities and quantification data were analyzed to examine differences between tissue blocks of different ages and assess the impact of technical and biological variability. An average of over 2000 proteins was seen in each sample with good reproducibility in terms of proteins identified and quantification for normal kidney tissue, with no significant effect of block age. Greater biological variability was apparent in the renal cell carcinoma tissue, possibly reflecting disease heterogeneity, but again there was good correlation between technical replicates and no significant effect of block age. These results indicate that archival storage time does not have a detrimental effect on protein profiling of FFPE tissues, supporting the use of such tissues in biomarker discovery studies. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Dynamic code block size for JPEG 2000

    NASA Astrophysics Data System (ADS)

    Tsai, Ping-Sing; LeCornec, Yann

    2008-02-01

    Since the standardization of the JPEG 2000, it has found its way into many different applications such as DICOM (digital imaging and communication in medicine), satellite photography, military surveillance, digital cinema initiative, professional video cameras, and so on. The unified framework of the JPEG 2000 architecture makes practical high quality real-time compression possible even in video mode, i.e. motion JPEG 2000. In this paper, we present a study of the compression impact using dynamic code block size instead of fixed code block size as specified in the JPEG 2000 standard. The simulation results show that there is no significant impact on compression if dynamic code block sizes are used. In this study, we also unveil the advantages of using dynamic code block sizes.

  16. An improved least cost routing approach for WDM optical network without wavelength converters

    NASA Astrophysics Data System (ADS)

    Bonani, Luiz H.; Forghani-elahabad, Majid

    2016-12-01

    Routing and wavelength assignment (RWA) problem has been an attractive problem in optical networks, and consequently several algorithms have been proposed in the literature to solve this problem. The most known techniques for the dynamic routing subproblem are fixed routing, fixed-alternate routing, and adaptive routing methods. The first one leads to a high blocking probability (BP) and the last one includes a high computational complexity and requires immense backing from the control and management protocols. The second one suggests a trade-off between performance and complexity, and hence we consider it to improve in our work. In fact, considering the RWA problem in a wavelength routed optical network with no wavelength converter, an improved technique is proposed for the routing subproblem in order to decrease the BP of the network. Based on fixed-alternate approach, the first k shortest paths (SPs) between each node pair is determined. We then rearrange the SPs according to a newly defined cost for the links and paths. Upon arriving a connection request, the sorted paths are consecutively checked for an available wavelength according to the most-used technique. We implement our proposed algorithm and the least-hop fixed-alternate algorithm to show how the rearrangement of SPs contributes to a lower BP in the network. The numerical results demonstrate the efficiency of our proposed algorithm in comparison with the others, considering different number of available wavelengths.

  17. Simple Genetic Distance-Optimized Field Deployments for Clonal Seed Orchards Based on Microsatellite Markers: As a Case of Chinese Pine Seed Orchard.

    PubMed

    Yuan, Huwei; Niu, Shihui; El-Kassaby, Yousry A; Li, Yue; Li, Wei

    2016-01-01

    Chinese pine seed orchards are in a period of transition from first-generation to advanced-generations. How to effectively select populations for second-generation seed orchards and significantly increase genetic gain through rational deployment have become major issues. In this study, we examined open- and control-pollinated progeny of the first-generation Chinese pine seed orchards in Zhengning (Gansu Province, China) and Xixian (Shanxi Province, China) to address issues related to phenotypic selection for high volume growth, genetic diversity analysis and genetic distance-based phylogenetic analysis of the selections by simple sequence repeats (SSRs), and phylogenetic relationship-based field deployment for advanced-generation orchards. In total, 40, 28, 20, and 13 superior individuals were selected from the large-scale no-pedigree open-pollinated progeny of Zhengning (ZN-NP), open-pollinated families of Zhengning (ZN-OP), open-pollinated families of Xixian (XX-OP), and control-pollinated families of Xixian, with mean volume dominance ratios of 0.83, 0.15, 0.25, and 0.20, respectively. Phylogenetic relationship analysis of the ZN-NP and XX-OP populations showed that the 40 superior individuals in the ZN-NP selected population belonged to 23 families and could be further divided into five phylogenetic groups, and that families in the same group were closely related. Similarly, 20 families in the XX-OP population were related to varying degrees. Based on these results, we found that second-generation Chinese pine seed orchards in Zhengning and Xixian should adopt a grouped, unbalanced, complete, fixed block design and an unbalanced, incomplete, fixed block design, respectively. This study will provide practical references for applying molecular markers to establishing advanced-generation seed orchards.

  18. Wavelength converter placement for different RWA algorithms in wavelength-routed all-optical networks

    NASA Astrophysics Data System (ADS)

    Chu, Xiaowen; Li, Bo; Chlamtac, Imrich

    2002-07-01

    Sparse wavelength conversion and appropriate routing and wavelength assignment (RWA) algorithms are the two key factors in improving the blocking performance in wavelength-routed all-optical networks. It has been shown that the optimal placement of a limited number of wavelength converters in an arbitrary mesh network is an NP complete problem. There have been various heuristic algorithms proposed in the literature, in which most of them assume that a static routing and random wavelength assignment RWA algorithm is employed. However, the existing work shows that fixed-alternate routing and dynamic routing RWA algorithms can achieve much better blocking performance. Our study in this paper further demonstrates that the wavelength converter placement and RWA algorithms are closely related in the sense that a well designed wavelength converter placement mechanism for a particular RWA algorithm might not work well with a different RWA algorithm. Therefore, the wavelength converter placement and the RWA have to be considered jointly. The objective of this paper is to investigate the wavelength converter placement problem under fixed-alternate routing algorithm and least-loaded routing algorithm. Under the fixed-alternate routing algorithm, we propose a heuristic algorithm called Minimum Blocking Probability First (MBPF) algorithm for wavelength converter placement. Under the least-loaded routing algorithm, we propose a heuristic converter placement algorithm called Weighted Maximum Segment Length (WMSL) algorithm. The objective of the converter placement algorithm is to minimize the overall blocking probability. Extensive simulation studies have been carried out over three typical mesh networks, including the 14-node NSFNET, 19-node EON and 38-node CTNET. We observe that the proposed algorithms not only outperform existing wavelength converter placement algorithms by a large margin, but they also can achieve almost the same performance comparing with full wavelength conversion under the same RWA algorithm.

  19. Thermoreversible networks for moldable photo-responsive elastomers (Presentation Recording)

    NASA Astrophysics Data System (ADS)

    Kornfield, Julia A.; Kurji, Zuleikha

    2015-10-01

    Soft-solids that retain the responsive optical anisotropy of liquid crystals (LC) can be used as mechano-optical, electro-optical and electro-mechanical elements. We use self-assembly of block copolymers to create reversible LC gels and elastomers that flow at elevated temperatures and physically cross link upon cooling. In the melt, they can be spun, coated or molded. Segregation of the end-blocks forms uniform and uniformly spaced crosslinks. Matched sets of block copolymers are synthesized from a single "prepolymer." Specifically, we begin with polymers having polystyrene (PS) end blocks and a poly(1,2-butadiene) midblock. The pendant vinyl groups along the backbone of the midblock are used to graft mesogens, converting it to a side-group LC polymer (SGLCP). In the present case, cyanobiphenyl groups are used as the nonphotoresponsive mesogens and azobenzene groups are used as photoresponsive mesogens. Here we show that matched pairs of block copolymers, with and without photo-responsive mesogens, provide model systems in which the optical density can be adjusted while holding other properties fixed (cross-link density, modulus, birefringence, isotropic-nematic transition temperature). For example, a triblock in which the SGLCP block has 95% cyanobiphenyl and 5% azo side groups is miscible with one having 100% cyanobiphenyl side groups. Simply blending the two gives a series of LC elastomers that have from 0 to 5% azo, while having all other physical properties matched. Results will be presented that show the outcomesof this approach to systematic and largely independent control of optical density and photo-mechanical sensitivity.

  20. Role of an anatomically contoured plate and metal block for balanced stability between the implant and lateral hinge in open-wedge high-tibial osteotomy.

    PubMed

    Jang, Young Woong; Lim, DoHyung; Seo, Hansol; Lee, Myung Chul; Lee, O-Sung; Lee, Yong Seuk

    2018-07-01

    Open-wedge high tibial osteotomy (OWHTO) is a well-established surgical option for medial compartment osteoarthritis of the varus knee. The initial strength of the fixation plate is critical for successful correction maintenance and healing of the osteotomy site. This study was conducted to verify if a newly designed anatomical plate (LCfit) improves the stability of both the medial implant and lateral hinge area, as well as to evaluate how the metal block contributes to both medial and lateral stability. A finite element (FE) tibial model was combined with TomoFix plate, a LCfit plate with and without a metal block. Data analysis was conducted to evaluate the balanced stability, which refers to the enforced lateral stability resulting from redistribution of overall stress. We assessed the balanced stability of the medial implant and lateral hinge area in three cases using the same Sawbones and loads using the tibia FE model. The LCfit plate reduced stress by 23.1% at the lateral hinge compared to the TomoFix plate (TomoFix vs. LCfit: 34.2 ± 23.3 MPa vs. 26.3 ± 17.5 MPa). The LCfit plate with a metal block reduced stress by 40.1% at the medial plate (210.1 ± 64.2 MPa vs. 125.8 ± 65.7 MPa) and by 31.2% (26.3 ± 17.5 MPa vs. 18.1 ± 12.1 MPa) at the lateral hinge area compared to the reduction using the LCfit plate without a metal block. The newly designed fixation system for OWHTO balanced the overall stress distribution and reduced stress at the lateral hinge area compared to that using a conventional fixation system. The addition of the metal block showed additional benefits for balanced stability between the medial implant and lateral hinge area. However, this conclusion could only be drawn using the FE model in this study. Therefore, further clinical studies are necessary to reveal the clinical effect of reduced lateral stress on the occurrence of the lateral hinge fracture and the biologic effect of the metal block on the healing of the medial cortex.

  1. Using IFN-γ antibodies to identify the pathogens of fungal rhinosinusitis: A novel immunohistochemical approach

    PubMed Central

    Yan, Yuyan; Zhao, Zuotao; Dong, Gehong; Han, Yiding; Yang, Dongmei; Yin, Hongyan; Piao, Yingshi; He, Chunyan; Tian, Cheng; Wan, Hongfei; Li, Xue; Jin, Yulan; Fang, Jugao; Liu, Honggang

    2018-01-01

    Fungal rhinosinusitis (FRS) is commonly caused by various Aspergillus species (spp) and Mucorales fungi, and the treatment and prognosis of cases differ depending on the causative fungus. The present study describes a novel immunohistochemical method that has high sensitivity and specificity for distinguishing between these two types of fungi in patients with FRS. Three groups were included in the study. Group A included formalin-fixed paraffin-embedded blocks of 51 nasal tissue specimens of patients with FRS (27 Aspergillus spp and 24 Mucorales) that were continuously obtained from the Department of Pathology of Tongren Hospital in Beijing as the experimental group and 34 cultures (26 Aspergillus spp and 8 Mucorales) of FRS that were randomly selected from the bacterial laboratory of Tongren Hospital in Beijing to verify the staining results of the paraffin-embedded blocks. Formalin-fixed paraffin-embedded blocks of 10 esophageal cancer specimens were included in Group B as the positive control group. All specimens in Groups A and B were stained with interferon-γ (IFN-γ) antibody. Group C consisted of the same specimens as described in Group A, however, when performing the immunohistochemical assay, IFN-γ antibody was replaced by PBS and this served as the negative control group. The differences in IFN-γ immunohistochemical staining between Aspergillus spp and Mucorales were analyzed. Staining of IFN-γ in paraffin-embedded samples was positive in 92.6% (25/27) of specimens in which Aspergillus spp were the causative pathogen, which was significantly higher compared with specimens in which Mucorales was causative (P<0.001), with only 4.2% (1/24) of specimens staining positive for IFN-γ. Immunohistochemical staining of cell cultures was 100% positive for Aspergillus spp, whereas all Mucorales were negative. Thus, the results of the current study indicated that IFN-γ antibody immunohistochemical staining may be used as a novel diagnostic tool to distinguish between Aspergillus spp and Mucorales when identifying the causative agent in FRS, providing a useful supplementary test to the current immunohistochemical methods in the clinical diagnosis of FRS. PMID:29286163

  2. Regulation of the expression of the cell-cycle gene ftsZ by DicF antisense RNA. Division does not require a fixed number of FtsZ molecules.

    PubMed

    Tétart, F; Bouché, J P

    1992-03-01

    We show that the 53-nucleotide RNA molecule encoded by gene dicF blocks cell division in Escherichia coli by inhibiting the translation of ftsZ mRNA. Such a role for dicF had been predicted on the basis of the complementarity of DicF RNA with the ribosome-binding region of the ftsZ mRNA. An analysis of ftsZ expression at its chromosomal locus, and of an ftsZ-lacZ translational fusion controlled by promoters ftsZ1p and ftsZ2p only, indicates that ftsZ is not autoregulated. Partial inhibition of FtsZ synthesis leads to increased cell size. However, the number of FtsZ molecules per cell can be reduced threefold without affecting the division rate significantly. Our results suggest that septation is not triggered by a fixed number of newly synthesized FtsZ molecules per cell.

  3. GAS BEARING

    DOEpatents

    Skarstrom, C.W.

    1960-09-01

    A gas lubricated bearing for a rotating shaft is described. The assembly comprises a stationary collar having an annular member resiliently supported thereon. The collar and annular member are provided with cooperating gas passages arranged for admission of pressurized gas which supports and lubricates a bearing block fixed to the rotatable shaft. The resilient means for the annular member support the latter against movement away from the bearing block when the assembly is in operation.

  4. The Resin-Embedded Cornea Prepared Via Rapid Processing Protocol : A Good Histomorphometric Target for Clinical Investigation in Ophthalmology and Optometry

    PubMed Central

    Cheah, Pike See; Mohidin, Norhani; Mohd Ali, Bariah; Maung, Myint; Latif, Azian Abdul

    2008-01-01

    This study illustrates and quantifies the changes on corneal tissue between the paraffin-embedded and resin-embedded blocks and thus, selects a better target in investigational ophthalmology and optometry via light microscopy. Corneas of two cynomolgus monkeys (Macaca fascicularis) were used in this study. The formalin-fixed cornea was prepared in paraffin block via the conventional tissue processing protocol (4-day protocol) and stained with haematoxylin and eosin. The glutaraldehyde-fixed cornea was prepared in resin block via the rapid and modified tissue processing procedure (1.2-day protocol) and stained with toluidine blue. The paraffin-embedded sample exhibits various undesired tissue damage and artifact such as thinner epithelium (due to the substantial volumic extraction from the tissue), thicker stroma layer (due to the separation of lamellae and the presence of voids) and the distorted endothelium. In contrast, the resin-embedded corneal tissue has demonstrated satisfactory corneal ultrastructural preservation. The rapid and modified tissue processing method for preparing the resin-embedded is particularly beneficial to accelerate the microscopic evaluation in ophthalmology and optometry. PMID:22570589

  5. Quality Control of RNA Preservation and Extraction from Paraffin-Embedded Tissue: Implications for RT-PCR and Microarray Analysis

    PubMed Central

    Pichler, Martin; Zatloukal, Kurt

    2013-01-01

    Analysis of RNA isolated from fixed and paraffin-embedded tissues is widely used in biomedical research and molecular pathological diagnostics. We have performed a comprehensive and systematic investigation of the impact of factors in the pre-analytical workflow, such as different fixatives, fixation time, RNA extraction method and storage of tissues in paraffin blocks, on several downstream reactions including complementary DNA (cDNA) synthesis, quantitative reverse transcription polymerase chain reaction (qRT-PCR) and microarray hybridization. We compared the effects of routine formalin fixation with the non-crosslinking, alcohol-based Tissue Tek Xpress Molecular Fixative (TTXMF, Sakura Finetek), and cryopreservation as gold standard for molecular analyses. Formalin fixation introduced major changes into microarray gene expression data and led to marked gene-to-gene variations in delta-ct values of qRT-PCR. We found that qRT-PCR efficiency and gene-to-gene variations were mainly attributed to differences in the efficiency of cDNA synthesis as the most sensitive step. These differences could not be reliably detected by quality assessment of total RNA isolated from formalin-fixed tissues by electrophoresis or spectrophotometry. Although RNA from TTXMF fixed samples was as fragmented as RNA from formalin fixed samples, much higher cDNA yield and lower ct-values were obtained in qRT-PCR underlining the negative impact of crosslinking by formalin. In order to better estimate the impact of pre-analytical procedures such as fixation on the reliability of downstream analysis, we applied a qRT-PCR-based assay using amplicons of different length and an assay measuring the efficiency of cDNA generation. Together these two assays allowed better quality assessment of RNA extracted from fixed and paraffin-embedded tissues and should be used to supplement quality scores derived from automated electrophoresis. A better standardization of the pre-analytical workflow, application of additional quality controls and detailed sample information would markedly improve the comparability and reliability of molecular studies based on formalin-fixed and paraffin-embedded tissue samples. PMID:23936242

  6. Fiber alignment apparatus and method

    DOEpatents

    Kravitz, Stanley H.; Warren, Mial Evans; Snipes, Jr., Morris Burton; Armendariz, Marcelino Guadalupe; Word, V., James Cole

    1997-01-01

    A fiber alignment apparatus includes a micro-machined nickel spring that captures and locks arrays of single mode fibers into position. The design consists of a movable nickel leaf shaped spring and a fixed pocket where fibers are held. The fiber is slid between the spring and a fixed block, which tensions the spring. When the fiber reaches the pocket, it automatically falls into the pocket and is held by the pressure of the leaf spring.

  7. Fiber alignment apparatus and method

    DOEpatents

    Kravitz, S.H.; Warren, M.E.; Snipes, M.B. Jr.; Armendariz, M.G.; Word, J.C. V

    1997-08-19

    A fiber alignment apparatus includes a micro-machined nickel spring that captures and locks arrays of single mode fibers into position. The design consists of a movable nickel leaf shaped spring and a fixed pocket where fibers are held. The fiber is slid between the spring and a fixed block, which tensions the spring. When the fiber reaches the pocket, it automatically falls into the pocket and is held by the pressure of the leaf spring. 8 figs.

  8. Block-based scalable wavelet image codec

    NASA Astrophysics Data System (ADS)

    Bao, Yiliang; Kuo, C.-C. Jay

    1999-10-01

    This paper presents a high performance block-based wavelet image coder which is designed to be of very low implementational complexity yet with rich features. In this image coder, the Dual-Sliding Wavelet Transform (DSWT) is first applied to image data to generate wavelet coefficients in fixed-size blocks. Here, a block only consists of wavelet coefficients from a single subband. The coefficient blocks are directly coded with the Low Complexity Binary Description (LCBiD) coefficient coding algorithm. Each block is encoded using binary context-based bitplane coding. No parent-child correlation is exploited in the coding process. There is also no intermediate buffering needed in between DSWT and LCBiD. The compressed bit stream generated by the proposed coder is both SNR and resolution scalable, as well as highly resilient to transmission errors. Both DSWT and LCBiD process the data in blocks whose size is independent of the size of the original image. This gives more flexibility in the implementation. The codec has a very good coding performance even the block size is (16,16).

  9. MISR Level 2 TOA/Cloud Versioning

    Atmospheric Science Data Center

    2017-10-11

    ... at this level. Software has been ported over to Linux. The Broadband Albedos have been fixed. New ancillary files: ... Difference Vectors implemented. Block Center Times for AN camera added to product. New ancillary files: ...

  10. Multimodal Friction Ignition Tester

    NASA Technical Reports Server (NTRS)

    Davis, Eddie; Howard, Bill; Herald, Stephen

    2009-01-01

    The multimodal friction ignition tester (MFIT) is a testbed for experiments on the thermal and mechanical effects of friction on material specimens in pressurized, oxygen-rich atmospheres. In simplest terms, a test involves recording sensory data while rubbing two specimens against each other at a controlled normal force, with either a random stroke or a sinusoidal stroke having controlled amplitude and frequency. The term multimodal in the full name of the apparatus refers to a capability for imposing any combination of widely ranging values of the atmospheric pressure, atmospheric oxygen content, stroke length, stroke frequency, and normal force. The MFIT was designed especially for studying the tendency toward heating and combustion of nonmetallic composite materials and the fretting of metals subjected to dynamic (vibrational) friction forces in the presence of liquid oxygen or pressurized gaseous oxygen test conditions approximating conditions expected to be encountered in proposed composite material oxygen tanks aboard aircraft and spacecraft in flight. The MFIT includes a stainless-steel pressure vessel capable of retaining the required test atmosphere. Mounted atop the vessel is a pneumatic cylinder containing a piston for exerting the specified normal force between the two specimens. Through a shaft seal, the piston shaft extends downward into the vessel. One of the specimens is mounted on a block, denoted the pressure block, at the lower end of the piston shaft. This specimen is pressed down against the other specimen, which is mounted in a recess in another block, denoted the slip block, that can be moved horizontally but not vertically. The slip block is driven in reciprocating horizontal motion by an electrodynamic vibration exciter outside the pressure vessel. The armature of the electrodynamic exciter is connected to the slip block via a horizontal shaft that extends into the pressure vessel via a second shaft seal. The reciprocating horizontal motion can be chosen to be random with a flat spectrum over the frequency range of 10 Hz to 1 kHz, or to be sinusoidal at any peak-to-peak amplitude up to 0.8 in. (.2 cm) and fixed or varying frequency up to 1 kHz. The temperatures of the specimen and of the vessel are measured by thermocouples. A digital video camera mounted outside the pressure vessel is aimed into the vessel through a sapphire window, with its focus fixed on the interface between the two specimens. A position transducer monitors the displacement of the pneumatic-cylinder shaft. The pressure in the vessel is also monitored. During a test, the output of the video camera, the temperatures, and the pneumatic-shaft displacement are monitored and recorded. The test is continued for a predetermined amount of time (typically, 10 minutes) or until either (1) the output of the position transducer shows a sudden change indicative of degradation of either or both specimens, (2) ignition or another significant reaction is observed, or (3) pressure in the vessel increases beyond a pre-set level that triggers an automatic shutdown.

  11. Development and investigation of the stressed-deformed state of the demountable foundation for support

    NASA Astrophysics Data System (ADS)

    Sabitov, L. S.; Kashapov, N. F.; Gilmanshin, I. R.; Strelkov, Yu M.; Khusainov, D. M.

    2017-09-01

    The development is demountable foundation for support, including separate reinforced concrete blocks in the form of prisms mounted on the surface of the base and pulled together by horizontal strands, and anchor devices for fixing the supports. The reinforced concrete blocks are made in the form of hollow prisms consisting of walls and square bottoms, and the strands are made in the form of bolts that tighten the walls along the top and bottom, while the anchoring devices for fixing the supports are made in the form of anchors on the bottom of the central prism and horizontal spacers between the support and the walls of the prism in its upper part. Numerical studies of the foundation have been carried out and its optimal sizes have been found in the PK Lira SAPR.

  12. Reducing the cesarean delivery rates for breech presentations: administration of spinal anesthesia facilitates manipulation to cephalic presentation, but is it cost saving?

    PubMed Central

    2014-01-01

    Background External cephalic version (ECV) is infrequently performed and 98% of breech presenting fetuses are delivered surgically. Neuraxial analgesia can increase the success rate of ECV significantly, potentially reducing cesarean delivery rates for breech presentation. The current study aims to determine whether the additional cost to the hospital of spinal anesthesia for ECV is offset by cost savings generated by reduced cesarean delivery. Methods In our tertiary hospital, three variables manpower, disposables, and fixed costs were calculated for ECV, ECV plus anesthetic doses of spinal block, vaginal delivery and cesarean delivery. Total procedure costs were compared for possible delivery pathways. Manpower data were obtained from management payroll, fixed costs by calculating cost/lifetime usage rate and disposables were micro-costed in 2008, expressed in 2013 NIS. Results Cesarean delivery is the most expensive option, 11670.54 NIS and vaginal delivery following successful ECV under spinal block costs 5497.2 NIS. ECV alone costs 960.21 NIS, ECV plus spinal anesthesia costs 1386.97 NIS. The highest individual cost items for vaginal, cesarean delivery and ECV were for manpower. Expensive fixed costs for cesarean delivery included operating room trays and postnatal hospitalization (minimum 3 days). ECV with spinal block is cheaper due to lower expected cesarean delivery rate and its lower associated costs. Conclusions The additional cost of the spinal anesthesia is offset by increased success rates for the ECV procedure resulting in reduction in the cesarean delivery rate. PMID:24564984

  13. Effects of a probiotic intervention in acute canine gastroenteritis--a controlled clinical trial.

    PubMed

    Herstad, H K; Nesheim, B B; L'Abée-Lund, T; Larsen, S; Skancke, E

    2010-01-01

    To evaluate the effect of a probiotic product in acute self-limiting gastroenteritis in dogs. Thirty-six dogs suffering from acute diarrhoea or acute diarrhoea and vomiting were included in the study. The trial was performed as a randomised, double blind and single centre study with stratified parallel group design. The animals were allocated to equal looking probiotic or placebo treatment by block randomisation with a fixed block size of six. The probiotic cocktail consisted of thermo-stabilised Lactobacillus acidophilus and live strains of Pediococcus acidilactici, Bacillus subtilis, Bacillus licheniformis and Lactobacillus farciminis. The time from initiation of treatment to the last abnormal stools was found to be significantly shorter (P = 0.04) in the probiotic group compared to placebo group, the mean time was 1.3 days and 2.2 days, respectively. The two groups were found nearly equal with regard to time from start of treatment to the last vomiting episode. The probiotic tested may reduce the convalescence time in acute self-limiting diarrhoea in dogs.

  14. No Spillover Effect of the Foreclosure Crisis on Weight Change: The Diabetes Study of Northern California (DISTANCE).

    PubMed

    Downing, Janelle; Karter, Andrew; Rodriguez, Hector; Dow, William H; Adler, Nancy; Schillinger, Dean; Warton, Margaret; Laraia, Barbara

    2016-01-01

    The emerging body of research suggests the unprecedented increase in housing foreclosures and unemployment between 2007 and 2009 had detrimental effects on health. Using data from electronic health records of 105,919 patients with diabetes in Northern California, this study examined how increases in foreclosure rates from 2006 to 2010 affected weight change. We anticipated that two of the pathways that explain how the spike in foreclosure rates affects weight gain-increasing stress and declining salutary health behaviors- would be acute in a population with diabetes because of metabolic sensitivity to stressors and health behaviors. Controlling for unemployment, housing prices, temporal trends, and time-invariant confounders with individual fixed effects, we found no evidence of an association between the foreclosure rate in each patient's census block of residence and body mass index. Our results suggest, although more than half of the population was exposed to at least one foreclosure within their census block, the foreclosure crisis did not independently impact weight change.

  15. Multiplex fluorescent immunoassay device based on magnetic nanoparticles

    NASA Astrophysics Data System (ADS)

    Godjevargova, T. I.; Ivanov, Y. L.; Dinev, D. D.

    2017-02-01

    Immunofluorescent analyzer based compact disc for simultaneous detection of 3 antibiotics in the same milk sample is consisting of two parts: CD-based immunofluorescence kit and optoelectronic fluorometer. Kit consists of 2 parts: Lyophilized immobilized antibodies on supermagnetic nanoparticles in Eppendorf tubes and CD-based microfluidic disk, in which are formed five chamber systems for simultaneous detecting of 5 separate samples. Each system consists of 2 chambers connected by a special micro channel acting as a hydrophobic valve. In the first chamber lyophilised conjugates of 3 antibiotics with accordingly 3 different fluorescent dyes are placed. The second chamber is for detection of fluorescent signal. The optoelectronic fluorometer is comprising of: integrated thermostatic block; mechanical-detecting unit (fluorometer) and block with controlling and visualizing electronics.The disc gets into a second block of the analyzer, where centrifugation is performed and also reporting of the fluorescent signals. This unit comprises a rotor on which the disc is fixed, permanent electromagnet in the form of a ring inserted under the disc and module of 3 LED diodes with emission filters for the relevant wavelengths corresponding to the used fluorescent dyes and 1 integrated photodiode, in front of which is mounted filter with 3 spectral peaks.The signal from the photodiode is detected by the electronic unit which is sensitive "lock-in" amplifier, the engine rotor management, control of thermostatic device and management of periphery of the analyzer, consisting of display and communications with computer.

  16. Coding the Assembly of Polyoxotungstates with a Programmable Reaction System.

    PubMed

    Ruiz de la Oliva, Andreu; Sans, Victor; Miras, Haralampos N; Long, De-Liang; Cronin, Leroy

    2017-05-01

    Chemical transformations are normally conducted in batch or flow mode, thereby allowing the chemistry to be temporally or spatially controlled, but these approaches are not normally combined dynamically. However, the investigation of the underlying chemistry masked by the self-assembly processes that often occur in one-pot reactions and exploitation of the potential of complex chemical systems requires control in both time and space. Additionally, maintaining the intermediate constituents of a self-assembled system "off equilibrium" and utilizing them dynamically at specific time intervals provide access to building blocks that cannot coexist under one-pot conditions and ultimately to the formation of new clusters. Herein, we implement the concept of a programmable networked reaction system, allowing us to connect discrete "one-pot" reactions that produce the building block{W 11 O 38 } ≡ {W 11 } under different conditions and control, in real time, the assembly of a series of polyoxometalate clusters {W 12 O 42 } ≡ {W 12 }, {W 22 O 74 } ≡ {W 22 } 1a, {W 34 O 116 } ≡ {W 34 } 2a, and {W 36 O 120 } ≡ {W 36 } 3a, using pH and ultraviolet-visible monitoring. The programmable networked reaction system reveals that is possible to assemble a range of different clusters using {W 11 }-based building blocks, demonstrating the relationship between the clusters within the family of iso-polyoxotungstates, with the final structural motif being entirely dependent on the building block libraries generated in each separate reaction space within the network. In total, this approach led to the isolation of five distinct inorganic clusters using a "fixed" set of reagents and using a fully automated sequence code, rather than five entirely different reaction protocols. As such, this approach allows us to discover, record, and implement complex one-pot reaction syntheses in a more general way, increasing the yield and reproducibility and potentially giving access to nonspecialists.

  17. Selective Blockade of Human Natural Killer Cells by a Monoclonal Antibody

    NASA Astrophysics Data System (ADS)

    Newman, Walter

    1982-06-01

    A murine monoclonal antibody, 13.1, which blocks human natural killer (NK) cell-mediated lysis, has been developed. Hybridoma 13.1 was derived by fusion of NS-1 cells with spleen cells from mice immunized with an enriched population of NK cells. Supernatants of growing hybridomas were screened for their ability to block NK cell-mediated lysis of K562 targets. Antibody 13.1 is an IgG1 with a single light chain type and it does not fix complement. The 13.1 antigen is expressed on all peripheral blood mononuclear cells, with an antigen density approximately 1/30th that of HLA antigen heavy chain. Pretreatment and washing experiments revealed that inhibition of cytotoxicity occurred at the effector cell level only. Significant blocking was achieved with nanogram quantities of antibody and was not due to toxic effects on NK cells. Likewise, controls with other antibodies of the same subclass demonstrated that blocking was not a consequence of mere binding to NK cells. When a panel of 17 NK cell-susceptible targets was tested, the lysis of only 5 of these was blocked, namely K562, HL-60, KG-1, Daudi, and HEL, a human erythroleukemic cell line. The lysis of 12 human B cell and T cell line targets was not inhibited. In addition to the demonstration that the 13.1 antigen is a crucial cell surface structure involved in NK lysis, a heterogeneity of target cell recognition has been revealed that argues for the proposition that individual NK cells have multiple recognitive capabilities.

  18. Is there a role for a test controller in the development of new ATC equipment?

    NASA Technical Reports Server (NTRS)

    Westrum, Ron

    1994-01-01

    Earl Wiener points out that human factors problems fixed during the R & D stage are paid for once. When they are not fixed during R & D, they are then paid for every day. How users are involved in the R & D process to assist in developing equipment is a critical issue. Effective involvement can produce real improvements. Ineffective involvement can produce inefficient kludges or systems that are actually dangerous. The underlying problem is the management of information and ideas. To develop a really generative system a great deal would have to change in the way that the FAA innovates. Use of test controllers would solve only some of the problems. For instance, we have cockpit resource management now for pilots; we may have it soon for controllers. But the management of ideas in the innovation process also needs intellectual resource management. Simply involving users is not enough. Brought in at the wrong point in the development process, users can block or compromise innovation. User involvement must be carefully considered. A test controller may be one solution to this problem. It might be necessary to have several kinds of test controllers (en route versus TRACON, for instance). No doubt further problems would surface in getting test controllers into operation. I would recommend that the FAA engage in a series of case studies of controller involvement in the innovation process. A systematic comparison of effective and ineffective cases would do much to clarify what we ought to do in the future. Unfortunately, I have been unable to find any cases where test controllers have been used. Perhaps we need to create some, to see how they work.

  19. DNA degrades during storage in formalin-fixed and paraffin-embedded tissue blocks.

    PubMed

    Guyard, Alice; Boyez, Alice; Pujals, Anaïs; Robe, Cyrielle; Tran Van Nhieu, Jeanne; Allory, Yves; Moroch, Julien; Georges, Odette; Fournet, Jean-Christophe; Zafrani, Elie-Serge; Leroy, Karen

    2017-10-01

    Formalin-fixed paraffin-embedded (FFPE) tissue blocks are widely used to identify clinically actionable molecular alterations or perform retrospective molecular studies. Our goal was to quantify degradation of DNA occurring during mid to long-term storage of samples in usual conditions. We selected 46 FFPE samples of surgically resected carcinomas of lung, colon, and urothelial tract, of which DNA had been previously extracted. We performed a second DNA extraction on the same blocks under identical conditions after a median period of storage of 5.5 years. Quantitation of DNA by fluorimetry showed a 53% decrease in DNA quantity after storage. Quantitative PCR (qPCR) targeting KRAS exon 2 showed delayed amplification of DNA extracted after storage in all samples but one. The qPCR/fluorimetry quantification ratio decreased from 56 to 15% after storage (p < 0.001). Overall, remaining proportion of DNA analyzable by qPCR represented only 11% of the amount obtained at first extraction. Maximal length of amplifiable DNA fragments assessed with a multiplex PCR was reduced in DNA extracted from stored tissue, indicating that DNA fragmentation had increased in the paraffin blocks during storage. Next-generation sequencing was performed on 12 samples and showed a mean 3.3-fold decrease in library yield and a mean 4.5-fold increase in the number of single-nucleotide variants detected after storage. In conclusion, we observed significant degradation of DNA extracted from the same FFPE block after 4 to 6 years of storage. Better preservation strategies should be considered for storage of FFPE biopsy specimens.

  20. Abnormal Q waves in right sided chest leads provoked by onset of right bundle-branch block in patients with anteroseptal infarction.

    PubMed Central

    Rosenbaum, M B; Girotti, L A; Lázzari, J O; Halpern, M S; Elizari, M V

    1982-01-01

    In five cases of anteroseptal myocardial infarction complicated by intermittent right bundle-branch block, the onset of right bundle-branch block provoked the appearance of abnormal Q waves in leads V1 and V2, whereas a small initial R wave was present in the same leads during normal conduction. The intermittency of the conduction disturbance indicated that the Q waves were "right bundle-branch block dependent". It was also apparent that right bundle-branch block shifted the electrical location of the infarct towards the right, and made it look much larger. Right bundle-branch block dependent Q waves may arise during the acute stage of an anterior infarct suggesting, fallaciously, that an acute extension has occurred, or during the chronic stage, leading to the erroneous supposition that a new infarct had developed. The abnormal Q waves anteroseptal infarction complicated by fixed right bundle-branch block, though obviously related to the infarct, may be dependent on the right bundle-branch block. PMID:7059400

  1. A novel design of a scanning probe microscope integrated with an ultramicrotome for serial block-face nanotomography

    NASA Astrophysics Data System (ADS)

    Efimov, Anton E.; Agapov, Igor I.; Agapova, Olga I.; Oleinikov, Vladimir A.; Mezin, Alexey V.; Molinari, Michael; Nabiev, Igor; Mochalov, Konstantin E.

    2017-02-01

    We present a new concept of a combined scanning probe microscope (SPM)/ultramicrotome apparatus. It enables "slice-and-view" scanning probe nanotomography measurements and 3D reconstruction of the bulk sample nanostructure from series of SPM images after consecutive ultrathin sections. The sample is fixed on a flat XYZ scanning piezostage mounted on the ultramicrotome arm. The SPM measuring head with a cantilever tip and a laser-photodiode tip detection system approaches the sample for SPM measurements of the block-face surface immediately after the ultramicrotome sectioning is performed. The SPM head is moved along guides that are also fixed on the ultramicrotome arm. Thereby, relative dysfunctional displacements of the tip, the sample, and the ultramicrotome knife are minimized. The design of the SPM head enables open frontal optical access to the sample block-face adapted for high-resolution optical lenses for correlative SPM/optical microscopy applications. The new system can be used in a wide range of applications for the study of 3D nanostructures of biological objects, biomaterials, polymer nanocomposites, and nanohybrid materials in various SPM and optical microscopy measuring modes.

  2. Effects on image quality of a 2D antiscatter grid in x-ray digital breast tomosynthesis: Initial experience using the dual modality (x-ray and molecular) breast tomosynthesis scanner

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patel, Tushita, E-mail: tp3rn@virginia.edu; Peppard, Heather; Williams, Mark B.

    2016-04-15

    Purpose: Radiation scattered from the breast in digital breast tomosynthesis (DBT) causes image degradation, including loss of contrast between cancerous and background tissue. Unlike in 2-dimensional (2D) mammography, an antiscatter grid cannot readily be used in DBT because changing alignment between the tube and detector during the scan would result in unacceptable loss of primary radiation. However, in the dual modality breast tomosynthesis (DMT) scanner, which combines DBT and molecular breast tomosynthesis, the tube and detector rotate around a common axis, thereby maintaining a fixed tube-detector alignment. This C-arm geometry raises the possibility of using a 2D (cellular) focused antiscattermore » grid. The purpose of this study is to assess change in image quality when using an antiscatter grid in the DBT portion of a DMT scan under conditions of fixed radiation dose. Methods: Two 2D focused prototype grids with 80 cm focal length were tested, one stack-laminated from copper (Cu) and one cast from a tungsten-polymer (W-poly). They were reciprocated using a motion scheme designed to maximize transmission of primary x-ray photons. Grid-in and grid-out scatter-to-primary ratios (SPRs) were measured for rectangular blocks of material simulating 30%, 50%, and 70% glandular tissue compositions. For assessment of changes in image quality through the addition of a grid, the Computerized Imaging Reference Systems, Inc., phantom Model 011A containing a set of 1 cm thick blocks simulating a range of glandular/adipose ratios from 0/100 to 100/0 was used. To simulate 6.5 and 8.5 cm thick compressed breasts, 1 cm thick slices of PMMA were added to the Model 011A phantom. DBT images were obtained with and without the grid, with exposure parameters fixed for a given compressed thickness. Signal-difference-to-noise ratios (SDNRs), contrast, and voxel value-based attenuation coefficients (μ) were measured for all blocks from reconstructed phantom images. Results: For 4, 6, and 8 cm tissue-equivalent block phantom thicknesses, the inclusion of the W-poly grid reduced the SPR by factors of 5, 6, and 5.8, respectively. For the same thicknesses, the copper grid reduced the SPR by factors of 3.9, 4.5, and 4.9. For the 011A phantom, the W-poly grid raised the SDNR of the 70/30 block from 0.8, −0.32, and −0.72 to 0.9, 0.76, and 0.062 for the 4.5, 6.5, and 8.5 cm phantoms, respectively. It raised the SDNR of the 100/0 block from 3.78, 1.95, and 1.0 to 3.79, 3.67, and 3.25 for the 4.5, 6.5, and 8.5 cm phantoms, respectively. Inclusion of the W-poly grid improved the accuracy of image-based μ values for all block compositions. However, smearing of attenuation across slices due to limited angular sampling decreases the sensitivity of voxel values to changing composition compared to theoretical μ values. Conclusions: Under conditions of fixed radiation dose to the breast, use of a 2D focused grid increased contrast, SDNR, and accuracy of estimated attenuation for mass-simulating block compositions in all phantom thicknesses tested, with the degree of improvement depending upon material composition. A 2D antiscatter grid can be usefully incorporated in DBT systems that employ fully isocentric tube-detector rotation.« less

  3. V/STOL tilt rotor study. Volume 5: A mathematical model for real time flight simulation of the Bell model 301 tilt rotor research aircraft

    NASA Technical Reports Server (NTRS)

    Harendra, P. B.; Joglekar, M. J.; Gaffey, T. M.; Marr, R. L.

    1973-01-01

    A mathematical model for real-time flight simulation of a tilt rotor research aircraft was developed. The mathematical model was used to support the aircraft design, pilot training, and proof-of-concept aspects of the development program. The structure of the mathematical model is indicated by a block diagram. The mathematical model differs from that for a conventional fixed wing aircraft principally in the added requirement to represent the dynamics and aerodynamics of the rotors, the interaction of the rotor wake with the airframe, and the rotor control and drive systems. The constraints imposed on the mathematical model are defined.

  4. Reconfigurable modular computer networks for spacecraft on-board processing

    NASA Technical Reports Server (NTRS)

    Rennels, D. A.

    1978-01-01

    The core electronics subsystems on unmanned spacecraft, which have been sent over the last 20 years to investigate the moon, Mars, Venus, and Mercury, have progressed through an evolution from simple fixed controllers and analog computers in the 1960's to general-purpose digital computers in current designs. This evolution is now moving in the direction of distributed computer networks. Current Voyager spacecraft already use three on-board computers. One is used to store commands and provide overall spacecraft management. Another is used for instrument control and telemetry collection, and the third computer is used for attitude control and scientific instrument pointing. An examination of the control logic in the instruments shows that, for many, it is cost-effective to replace the sequencing logic with a microcomputer. The Unified Data System architecture considered consists of a set of standard microcomputers connected by several redundant buses. A typical self-checking computer module will contain 23 RAMs, two microprocessors, one memory interface, three bus interfaces, and one core building block.

  5. Malleable architecture generator for FPGA computing

    NASA Astrophysics Data System (ADS)

    Gokhale, Maya; Kaba, James; Marks, Aaron; Kim, Jang

    1996-10-01

    The malleable architecture generator (MARGE) is a tool set that translates high-level parallel C to configuration bit streams for field-programmable logic based computing systems. MARGE creates an application-specific instruction set and generates the custom hardware components required to perform exactly those computations specified by the C program. In contrast to traditional fixed-instruction processors, MARGE's dynamic instruction set creation provides for efficient use of hardware resources. MARGE processes intermediate code in which each operation is annotated by the bit lengths of the operands. Each basic block (sequence of straight line code) is mapped into a single custom instruction which contains all the operations and logic inherent in the block. A synthesis phase maps the operations comprising the instructions into register transfer level structural components and control logic which have been optimized to exploit functional parallelism and function unit reuse. As a final stage, commercial technology-specific tools are used to generate configuration bit streams for the desired target hardware. Technology- specific pre-placed, pre-routed macro blocks are utilized to implement as much of the hardware as possible. MARGE currently supports the Xilinx-based Splash-2 reconfigurable accelerator and National Semiconductor's CLAy-based parallel accelerator, MAPA. The MARGE approach has been demonstrated on systolic applications such as DNA sequence comparison.

  6. Performance analysis of a generalized upset detection procedure

    NASA Technical Reports Server (NTRS)

    Blough, Douglas M.; Masson, Gerald M.

    1987-01-01

    A general procedure for upset detection in complex systems, called the data block capture and analysis upset monitoring process is described and analyzed. The process consists of repeatedly recording a fixed amount of data from a set of predetermined observation lines of the system being monitored (i.e., capturing a block of data), and then analyzing the captured block in an attempt to determine whether the system is functioning correctly. The algorithm which analyzes the data blocks can be characterized in terms of the amount of time it requires to examine a given length data block to ascertain the existence of features/conditions that have been predetermined to characterize the upset-free behavior of the system. The performance of linear, quadratic, and logarithmic data analysis algorithms is rigorously characterized in terms of three performance measures: (1) the probability of correctly detecting an upset; (2) the expected number of false alarms; and (3) the expected latency in detecting upsets.

  7. Numerical solution of second order ODE directly by two point block backward differentiation formula

    NASA Astrophysics Data System (ADS)

    Zainuddin, Nooraini; Ibrahim, Zarina Bibi; Othman, Khairil Iskandar; Suleiman, Mohamed; Jamaludin, Noraini

    2015-12-01

    Direct Two Point Block Backward Differentiation Formula, (BBDF2) for solving second order ordinary differential equations (ODEs) will be presented throughout this paper. The method is derived by differentiating the interpolating polynomial using three back values. In BBDF2, two approximate solutions are produced simultaneously at each step of integration. The method derived is implemented by using fixed step size and the numerical results that follow demonstrate the advantage of the direct method as compared to the reduction method.

  8. Performance Evaluation of Frequency Transform Based Block Classification of Compound Image Segmentation Techniques

    NASA Astrophysics Data System (ADS)

    Selwyn, Ebenezer Juliet; Florinabel, D. Jemi

    2018-04-01

    Compound image segmentation plays a vital role in the compression of computer screen images. Computer screen images are images which are mixed with textual, graphical, or pictorial contents. In this paper, we present a comparison of two transform based block classification of compound images based on metrics like speed of classification, precision and recall rate. Block based classification approaches normally divide the compound images into fixed size blocks of non-overlapping in nature. Then frequency transform like Discrete Cosine Transform (DCT) and Discrete Wavelet Transform (DWT) are applied over each block. Mean and standard deviation are computed for each 8 × 8 block and are used as features set to classify the compound images into text/graphics and picture/background block. The classification accuracy of block classification based segmentation techniques are measured by evaluation metrics like precision and recall rate. Compound images of smooth background and complex background images containing text of varying size, colour and orientation are considered for testing. Experimental evidence shows that the DWT based segmentation provides significant improvement in recall rate and precision rate approximately 2.3% than DCT based segmentation with an increase in block classification time for both smooth and complex background images.

  9. Six-flow operations for catalyst development in Fischer-Tropsch synthesis: Bridging the gap between high-throughput experimentation and extensive product evaluation

    NASA Astrophysics Data System (ADS)

    Sartipi, Sina; Jansma, Harrie; Bosma, Duco; Boshuizen, Bart; Makkee, Michiel; Gascon, Jorge; Kapteijn, Freek

    2013-12-01

    Design and operation of a "six-flow fixed-bed microreactor" setup for Fischer-Tropsch synthesis (FTS) is described. The unit consists of feed and mixing, flow division, reaction, separation, and analysis sections. The reactor system is made of five heating blocks with individual temperature controllers, assuring an identical isothermal zone of at least 10 cm along six fixed-bed microreactor inserts (4 mm inner diameter). Such a lab-scale setup allows running six experiments in parallel, under equal feed composition, reaction temperature, and conditions of separation and analysis equipment. It permits separate collection of wax and liquid samples (from each flow line), allowing operation with high productivities of C5+ hydrocarbons. The latter is crucial for a complete understanding of FTS product compositions and will represent an advantage over high-throughput setups with more than ten flows where such instrumental considerations lead to elevated equipment volume, cost, and operation complexity. The identical performance (of the six flows) under similar reaction conditions was assured by testing a same catalyst batch, loaded in all microreactors.

  10. Performance factors in associative learning: assessment of the sometimes competing retrieval model.

    PubMed

    Witnauer, James E; Wojick, Brittany M; Polack, Cody W; Miller, Ralph R

    2012-09-01

    Previous simulations revealed that the sometimes competing retrieval model (SOCR; Stout & Miller, Psychological Review, 114, 759-783, 2007), which assumes local error reduction, can explain many cue interaction phenomena that elude traditional associative theories based on total error reduction. Here, we applied SOCR to a new set of Pavlovian phenomena. Simulations used a single set of fixed parameters to simulate each basic effect (e.g., blocking) and, for specific experiments using different procedures, used fitted parameters discovered through hill climbing. In simulation 1, SOCR was successfully applied to basic acquisition, including the overtraining effect, which is context dependent. In simulation 2, we applied SOCR to basic extinction and renewal. SOCR anticipated these effects with both fixed parameters and best-fitting parameters, although the renewal effects were weaker than those observed in some experiments. In simulation 3a, feature-negative training was simulated, including the often observed transition from second-order conditioning to conditioned inhibition. In simulation 3b, SOCR predicted the observation that conditioned inhibition after feature-negative and differential conditioning depends on intertrial interval. In simulation 3c, SOCR successfully predicted failure of conditioned inhibition to extinguish with presentations of the inhibitor alone under most circumstances. In simulation 4, cue competition, including blocking (4a), recovery from relative validity (4b), and unblocking (4c), was simulated. In simulation 5, SOCR correctly predicted that inhibitors gain more behavioral control than do excitors when they are trained in compound. Simulation 6 demonstrated that SOCR explains the slower acquisition observed following CS-weak shock pairings.

  11. Artificial induction of mito-gynogenetic diploids in large yellow croaker ( Pseudosciaena crocea) by hydrostatic pressure

    NASA Astrophysics Data System (ADS)

    Cai, Mingyi; Wu, Qingming; Liu, Xiande; Yao, Cuiluan; Chen, Qingkai; Wang, Zhiyong

    2010-07-01

    The present study investigated conditions for inducing mito-gynogenetic (endomitosis) diploids by hydrostatic pressure in the large yellow croaker Pseudosciaena crocea. In haploid control groups, the development of eggs was activated with ultraviolet radiated semen. All fry presented typical haploid syndrome in the haploid control groups, and were verified as haploids using cytometry. After hydrostatic pressure treatment, morphologically normal fry reappeared at different frequencies according to the intensity and time of pressure shock. Fry with normal appearance in the pressure treated groups were verified as gynogenetic double haploids (GDHs), containing only one allele from the female parent at all four diagnostic microsatellite loci. For a fixed duration of 3 min, the optimal intensity of blocking the first mitosis was determined to be 40 Mpa, which was similar to that of blocking the second meiosis. There was a “window” of starting time, from 36.1 min to 38.1 min post-insemination at 25.0±1.0°C, within which the production of GDHs was not significantly different. Maximum production of morphologically normal fries, 9.36%±2.97% of developed eggs, was found when the eggs were shocked with hydrostatic pressure at 40 Mpa for 3 min, starting from 38.1 min post insemination at 25.0±1.0°C.

  12. Continuous uniformly finite time exact disturbance observer based control for fixed-time stabilization of nonlinear systems with mismatched disturbances

    PubMed Central

    Liu, Chongxin; Liu, Hang

    2017-01-01

    This paper presents a continuous composite control scheme to achieve fixed-time stabilization for nonlinear systems with mismatched disturbances. The composite controller is constructed in two steps: First, uniformly finite time exact disturbance observers are proposed to estimate and compensate the disturbances. Then, based on adding a power integrator technique and fixed-time stability theory, continuous fixed-time stable state feedback controller and Lyapunov functions are constructed to achieve global fixed-time system stabilization. The proposed control method extends the existing fixed-time stable control results to high order nonlinear systems with mismatched disturbances and achieves global fixed-time system stabilization. Besides, the proposed control scheme improves the disturbance rejection performance and achieves performance recovery of nominal system. Simulation results are provided to show the effectiveness, the superiority and the applicability of the proposed control scheme. PMID:28406966

  13. Adaptive fixed-time trajectory tracking control of a stratospheric airship.

    PubMed

    Zheng, Zewei; Feroskhan, Mir; Sun, Liang

    2018-05-01

    This paper addresses the fixed-time trajectory tracking control problem of a stratospheric airship. By extending the method of adding a power integrator to a novel adaptive fixed-time control method, the convergence of a stratospheric airship to its reference trajectory is guaranteed to be achieved within a fixed time. The control algorithm is firstly formulated without the consideration of external disturbances to establish the stability of the closed-loop system in fixed-time and demonstrate that the convergence time of the airship is essentially independent of its initial conditions. Subsequently, a smooth adaptive law is incorporated into the proposed fixed-time control framework to provide the system with robustness to external disturbances. Theoretical analyses demonstrate that under the adaptive fixed-time controller, the tracking errors will converge towards a residual set in fixed-time. The results of a comparative simulation study with other recent methods illustrate the remarkable performance and superiority of the proposed control method. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  14. Effects of erosive, cariogenic or combined erosive/cariogenic challenges on human enamel: an in situ/ex vivo study.

    PubMed

    Honório, H M; Rios, D; Santos, C F; Magalhães, A C; Buzalaf, M A R; Machado, M A A M

    2008-01-01

    Individuals with cariogenic diet can also consume erosive beverages. Thus, it seems necessary to investigate a possible caries/erosion interaction. To test in situ/ex vivo a combination of these challenges, 11 subjects wore intraoral appliances containing four enamel blocks randomly assigned. In the first 2-week phase, the appliances were immersed in a cola drink 3 times/day. Two blocks were free of plaque (erosion only: EO) and two blocks were covered with plaque (erosion + plaque: EP). In the second 2-week phase, four new blocks were all covered with plaque and subjected to a sucrose solution 8 times/day. Among the four new blocks, two were also subjected to the cola drink 3 times/day (erosion + caries: EC) while the other two were not (caries only: CO). Thus, in EO, the specimens were fixed at the intraoral appliance level. In EP, EC and CO they were fixed 1.0 mm under the appliance level and covered with plastic meshes for dental plaque accumulation. Changes in wear and hardness were measured. Data were tested using ANOVA and Tukey's test (p < 0.05). Mean values of wear (microm) and change in hardness (kp/mm(2)) were: EO 4.82/310; EP 0.14/48; EC 0.34/245; CO 0.42/309. With respect to surface softening, EP and EC differed significantly from each other and from EO and CO, which did not differ significantly. EO presented significantly higher wear than the other groups. The data suggest that the presence of dental plaque can decrease the acid attack of an erosive drink and the association of erosive and cariogenic challenges showed less enamel alterations when compared to erosive or cariogenic challenges only. (c) 2008 S. Karger AG, Basel.

  15. The Cellient System for Paraffin Histology Can Be Combined with HPV Testing and Morphotyping the Vaginal Microbiome Thanks to BoonFixing

    PubMed Central

    Boon, Mathilde E.

    2013-01-01

    The Cellient Automated Cell Block System (Hologic) can be used to process cervical scrapes to paraffin sections. For the first study on this subject, cervical scrapes were fixed in the formalin-free fixative BoonFix. This pilot study was limited to cases classified as atypical squamous lesion of unknown significance (ASCUS) and high-grade squamous lesion (HSIL) as diagnosed in the ThinPrep slide. The Cellient paraffin sections were classified into negative, atypical, CIN 1, CIN 2, and CIN 3. Multiple HPV genotypes were encountered in 79% of the scrapes. This study showed that the Cellient system for paraffin sections can be combined with HPV testing thanks to the formalin-free BoonFix. In two additional studies it was shown that such samples can also be used for morphotyping the vaginal microbiome and preparing cytologic ThinPrep slides. PMID:23577033

  16. The Cellient System for Paraffin Histology Can Be Combined with HPV Testing and Morphotyping the Vaginal Microbiome Thanks to BoonFixing.

    PubMed

    Boon, Mathilde E

    2013-01-01

    The Cellient Automated Cell Block System (Hologic) can be used to process cervical scrapes to paraffin sections. For the first study on this subject, cervical scrapes were fixed in the formalin-free fixative BoonFix. This pilot study was limited to cases classified as atypical squamous lesion of unknown significance (ASCUS) and high-grade squamous lesion (HSIL) as diagnosed in the ThinPrep slide. The Cellient paraffin sections were classified into negative, atypical, CIN 1, CIN 2, and CIN 3. Multiple HPV genotypes were encountered in 79% of the scrapes. This study showed that the Cellient system for paraffin sections can be combined with HPV testing thanks to the formalin-free BoonFix. In two additional studies it was shown that such samples can also be used for morphotyping the vaginal microbiome and preparing cytologic ThinPrep slides.

  17. Optimization of self-aligned double patterning (SADP)-compliant layout designs using pattern matching for sub-20nm metal routing

    NASA Astrophysics Data System (ADS)

    Wang, Lynn T.-N.; Schroeder, Uwe Paul; Madhavan, Sriram

    2017-03-01

    A pattern-based methodology for optimizing SADP-compliant layout designs is developed based on identifying cut mask patterns and replacing them with pre-characterized fixing solutions. A pattern-based library of difficult-tomanufacture cut patterns with pre-characterized fixing solutions is built. A pattern-based engine searches for matching patterns in the decomposed layouts. When a match is found, the engine opportunistically replaces the detected pattern with a pre-characterized fixing solution. The methodology was demonstrated on a 7nm routed metal2 block. A small library of 30 cut patterns increased the number of more manufacturable cuts by 38% and metal-via enclosure by 13% with a small parasitic capacitance impact of 0.3%.

  18. A case study of sea breeze blocking regulated by sea surface temperature along the English south coast

    NASA Astrophysics Data System (ADS)

    Sweeney, J. K.; Chagnon, J. M.; Gray, S. L.

    2013-09-01

    The sensitivity of sea breeze structure to sea surface temperature (SST) and coastal orography is investigated in convection-permitting Met Office Unified Model simulations of a case study along the south coast of England. Changes in SST of 1 K are shown to significantly modify the structure of the sea breeze. On the day of the case study the sea breeze was partially blocked by coastal orography, particularly within Lyme Bay. The extent to which the flow is blocked depends strongly on the static stability of the marine boundary layer. In experiments with colder SST, the marine boundary layer is more stable, and the degree of blocking is more pronounced. The implications of prescribing fixed SST from climatology in numerical weather prediction model forecasts of the sea breeze are discussed.

  19. Single-injection or continuous femoral nerve block for total knee arthroplasty?

    PubMed

    Albrecht, Eric; Morfey, Dorothea; Chan, Vincent; Gandhi, Rajiv; Koshkin, Arkadiy; Chin, Ki Jinn; Robinson, Sylvie; Frascarolo, Philippe; Brull, Richard

    2014-05-01

    The ideal local anesthetic regime for femoral nerve block that balances analgesia with mobility after total knee arthroplasty (TKA) remains undefined. We compared two volumes and concentrations of a fixed dose of ropivacaine for continuous femoral nerve block after TKA to a single injection femoral nerve block with ropivacaine to determine (1) time to discharge readiness; (2) early pain scores and analgesic consumption; and (3) functional outcomes, including range of motion and WOMAC scores at the time of recovery. Ninety-nine patients were allocated to one of three continuous femoral nerve block groups for this randomized, placebo-controlled, double-blind trial: a high concentration group (ropivacaine 0.2% infusion), a low concentration group (ropivacaine 0.1% infusion), or a placebo infusion group (saline 0.9% infusion). Infusions were discontinued on postoperative Day (POD) 2. The primary outcome was time to discharge readiness. Secondary outcomes included opioid consumption, pain, and functional outcomes. Ninety-three patients completed the study protocol; the study was halted early because of unanticipated changes to pain protocols at the host institution, by which time only 61% of the required number of patients had been enrolled. With the numbers available, the mean time to discharge readiness was not different between groups (high concentration group, 62 hours [95% confidence interval [CI], 51-72 hours]; low concentration group, 73 hours [95% CI, 63-83 hours]; placebo infusion group 65 hours [95% CI, 56-75 hours]; p = 0.27). Patients in the low concentration group consumed significantly less morphine during the period of infusion (POD 1, high concentration group, 56 mg [95% CI, 42-70 mg]; low concentration group, 35 mg [95% CI, 27-43 mg]; placebo infusion group, 48 mg [95% CI, 38-59 mg], p = 0.02; POD 2, high concentration group, 50 mg [95% CI, 41-60 mg]; low concentration group, 33 mg [95% CI, 24-42 mg]; placebo infusion group, 39 mg [95% CI, 30-48 mg], p = 0.04); however, there were no important differences in pain scores or opioid-related side effects with the numbers available. Likewise, there were no important differences in functional outcomes between groups. Based on this study, which was terminated prematurely before the desired sample size could be achieved, we were unable to demonstrate that varying the concentration and volume of a fixed-dose ropivacaine infusion for continuous femoral nerve block influences time to discharge readiness when compared with a conventional single-injection femoral nerve block after TKA. A low concentration of ropivacaine infusion can reduce postoperative opioid consumption but without any important differences in pain scores, side effects, or functional outcomes. These pilot data may be used to inform the statistical power of future randomized trials. Level II, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  20. Induction of hapten-specific tolerance of human CD8+ urushiol (poison ivy)-reactive T lymphocytes.

    PubMed

    Kalish, R S; Wood, J A

    1997-03-01

    The interaction of CD28 with B7 molecules (CD80 or CD86) is an essential second signal for both the activation of CD4+ T cells through the T-cell receptor and the prevention of anergy. We studied the requirement of hapten-specific human CD8+ cells for CD28 co-stimulation in recognition of hapten, and anergy induction. Urushiol, the immunogenic hapten of poison ivy (Toxicodendron radicans), elicits a predominantly CD8+ T-cell response. Autologous PBMC were pre-incubated with urushiol prior to fixation by paraformaldehyde. Fixed antigen-presenting cells were unable to present urushiol to human CD8+ urushiol-specific T cells. Addition of anti-CD28, however, overcame this antigen-presenting defect, enabling CD8+ cells to proliferate. Fixation of antigen-presenting cells prevents upregulation of B7, and addition of anti-CD28 substitutes for this signal. Proliferation of CD8+ T cells in response to urushiol was blocked by CTLA4Ig, a recombinant fusion protein that blocks CD28/B7 interactions. Preincubation of urushiol-specific CD8+ cells with fixed PBMC + urushiol for 7 d induced anergy. Anergic CD8+ cells were viable and able to proliferate in response to IL-2, but not in response to urushiol. Induction of anergy required the presence of urushiol, and pre-incubation with irradiated PBMC + urushiol did not have this effect. It is proposed that anergy was induced by presentation of urushiol by fixed PBMC, in the absence of adequate co-stimulation signals. Induction of anergy by blocking of co-stimulation could potentially induce clinical hyposensitization to haptens.

  1. Ball catching in children with developmental coordination disorder: control of degrees of freedom.

    PubMed

    Utley, Andrea; Steenbergen, Bert; Astill, Sarah Louise

    2007-01-01

    This study investigated two-handed catching in eight children (four males, four females) aged 7 to 8 years (mean 7y 4mo [SD 3mo]) with developmental coordination disorder (DCD) and their age-matched controls (AMCs). Kinematic data were collected to examine Bernstein's (1967) notion of freezing and releasing degrees of freedom (DF). Participants were asked to catch a ball 30 times, delivered in three blocks of 10 trials. Video analysis showed that children with DCD caught significantly fewer balls than their AMCs (p< or =0.001) counterparts. Kinematic analyses showed that children with DCD exhibited smaller ranges of motion and less variable angular excursions of the elbow joints than their AMCs, and that their elbows are more rigidly coupled (p< or =0.001). These data suggest that children with DCD rigidly fix and couple their limbs to reduce the number of DF actively involved in the task.

  2. Performance of a visuomotor walking task in an augmented reality training setting.

    PubMed

    Haarman, Juliet A M; Choi, Julia T; Buurke, Jaap H; Rietman, Johan S; Reenalda, Jasper

    2017-12-01

    Visual cues can be used to train walking patterns. Here, we studied the performance and learning capacities of healthy subjects executing a high-precision visuomotor walking task, in an augmented reality training set-up. A beamer was used to project visual stepping targets on the walking surface of an instrumented treadmill. Two speeds were used to manipulate task difficulty. All participants (n = 20) had to change their step length to hit visual stepping targets with a specific part of their foot, while walking on a treadmill over seven consecutive training blocks, each block composed of 100 stepping targets. Distance between stepping targets was varied between short, medium and long steps. Training blocks could either be composed of random stepping targets (no fixed sequence was present in the distance between the stepping targets) or sequenced stepping targets (repeating fixed sequence was present). Random training blocks were used to measure non-specific learning and sequenced training blocks were used to measure sequence-specific learning. Primary outcome measures were performance (% of correct hits), and learning effects (increase in performance over the training blocks: both sequence-specific and non-specific). Secondary outcome measures were the performance and stepping-error in relation to the step length (distance between stepping target). Subjects were able to score 76% and 54% at first try for lower speed (2.3 km/h) and higher speed (3.3 km/h) trials, respectively. Performance scores did not increase over the course of the trials, nor did the subjects show the ability to learn a sequenced walking task. Subjects were better able to hit targets while increasing their step length, compared to shortening it. In conclusion, augmented reality training by use of the current set-up was intuitive for the user. Suboptimal feedback presentation might have limited the learning effects of the subjects. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Distributed estimation of sensors position in underwater wireless sensor network

    NASA Astrophysics Data System (ADS)

    Zandi, Rahman; Kamarei, Mahmoud; Amiri, Hadi

    2016-05-01

    In this paper, a localisation method for determining the position of fixed sensor nodes in an underwater wireless sensor network (UWSN) is introduced. In this simple and range-free scheme, the node localisation is achieved by utilising an autonomous underwater vehicle (AUV) that transverses through the network deployment area, and that periodically emits a message block via four directional acoustic beams. A message block contains the actual known AUV position as well as a directional dependent marker that allows a node to identify the respective transmit beam. The beams form a fixed angle with the AUV body. If a node passively receives message blocks, it could calculate the arithmetic mean of the coordinates existing in each messages sequence, to find coordinates at two different time instants via two different successive beams. The node position can be derived from the two computed positions of the AUV. The major advantage of the proposed localisation algorithm is that it is silent, which leads to energy efficiency for sensor nodes. The proposed method does not require any synchronisation among the nodes owing to being silent. Simulation results, using MATLAB, demonstrated that the proposed method had better performance than other similar AUV-based localisation methods in terms of the rates of well-localised sensor nodes and positional root mean square error.

  4. 47 CFR 101.1405 - Channeling plan.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Channeling plan. 101.1405 Section 101.1405 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE... Channeling plan. Each license shall have one spectrum block of 500 megahertz per geographic area that can be...

  5. 47 CFR 101.1405 - Channeling plan.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Channeling plan. 101.1405 Section 101.1405 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE... Channeling plan. Each license shall have one spectrum block of 500 megahertz per geographic area that can be...

  6. An integrated voice and data multiple-access scheme for a land-mobile satellite system

    NASA Technical Reports Server (NTRS)

    Li, V. O. K.; Yan, T.-Y.

    1984-01-01

    An analytical study is performed of the satellite requirements for a land mobile satellite system (LMSS). The spacecraft (MSAT-X) would be in GEO and would be compatible with multiple access by mobile radios and antennas and fixed stations. The FCC has received a petition from NASA to reserve the 821-825 and 866-870 MHz frequencies for the LMSS, while communications with fixed earth stations would be in the Ku band. MSAT-X transponders would alter the frequencies of signal and do no processing in the original configuration considered. Channel use would be governed by an integrated demand-assigned, multiple access protocol, which would divide channels into reservation and information channels, governed by a network management center. Further analyses will cover tradeoffs between data and voice users, probability of blocking, and the performance impacts of on-board switching and variable bandwidth assignment. Initial calculations indicate that a large traffic volume can be handled with acceptable delays and voice blocking probabilities.

  7. An integrated voice and data multiple-access scheme for a land-mobile satellite system

    NASA Astrophysics Data System (ADS)

    Li, V. O. K.; Yan, T.-Y.

    1984-11-01

    An analytical study is performed of the satellite requirements for a land mobile satellite system (LMSS). The spacecraft (MSAT-X) would be in GEO and would be compatible with multiple access by mobile radios and antennas and fixed stations. The FCC has received a petition from NASA to reserve the 821-825 and 866-870 MHz frequencies for the LMSS, while communications with fixed earth stations would be in the Ku band. MSAT-X transponders would alter the frequencies of signal and do no processing in the original configuration considered. Channel use would be governed by an integrated demand-assigned, multiple access protocol, which would divide channels into reservation and information channels, governed by a network management center. Further analyses will cover tradeoffs between data and voice users, probability of blocking, and the performance impacts of on-board switching and variable bandwidth assignment. Initial calculations indicate that a large traffic volume can be handled with acceptable delays and voice blocking probabilities.

  8. Bone remodeling in onlay beta-tricalcium phosphate and coral grafts to rat calvaria: microcomputerized tomography analysis.

    PubMed

    Anavi, Yakir; Avishai, Gal; Calderon, Shlomo; Allon, Dror M

    2011-08-01

    This study was conducted to establish the efficiency of microcomputerized tomography (micro-CT) in detection of trabecular bone remodeling of onlay grafts in a rodent calvaria model, and to compare bone remodeling after onlay grafts with beta-tricalcium phosphate (TCP) or coral calcium carbonate. Ten rats received calvarial onlay blocks-5 with TCP and 5 with coral calcium carbonate. The grafts were fixed with a titanium miniplate screw and were covered with a collagen resorbable membrane. Three months after surgery, the calvaria were segmented, and a serial 3-dimensional micro-CT scan of the calvarium and grafted bone block at 16-micrometer resolution was performed. Image analysis software was used to calculate the percentage of newly formed bone from the total block size. Newly formed bone was present adjacent to the calvarium and screw in all specimens. The mean area of newly formed bone of the total block size ranged from 34.67%-38.34% in the TCP blocks, and from 32.41%-34.72% in the coral blocks. In the TCP blocks, bone remodeling was found to be slightly higher than in the coral blocks. Micro-CT appears to be a precise, reproducible, specimen-nondestructive method of analysis of bone formation in onlay block grafts to rat calvaria.

  9. Banking for the future: an Australian experience in brain banking.

    PubMed

    Sarris, M; Garrick, T M; Sheedy, D; Harper, C G

    2002-06-01

    The New South Wales (NSW) Tissue Resource Centre (TRC) has been set up to provide Australian and international researchers with fixed and frozen brain tissue from cases that are well characterised, both clinically and pathologically, for projects related to neuropsychiatric and alcohol-related disorders. A daily review of the Department of Forensic Medicine provides initial information regarding a potential collection. If the case adheres to the strict inclusion criteria, the pathologist performing the postmortem examination is approached regarding retention of the brain tissue. The next of kin of the deceased is then contacted requesting permission to retain the brain for medical research. Cases are also obtained through donor programmes, where donors are assessed and consent to donate their brain during life. Once the brain is removed at autopsy, the brain is photographed, weighed and the volume determined, the brainstem and cerebellum are removed. The two hemispheres are divided, one hemisphere is fresh frozen and one fixed (randomised). Prior to freezing, the hemisphere is sliced into 1-cm coronal slices and a set of critical area blocks is taken. All frozen tissues are kept bagged at -80 degrees C. The other hemisphere is fixed in 15% buffered formalin for 2 weeks, embedded in agar and sliced at 3-mm intervals in the coronal plane. Tissue blocks from these slices are used for neuropathological analysis to exclude any other pathology. The TRC currently has 230 cases of both fixed and frozen material that has proven useful in a range of techniques in many research projects. These techniques include quantitative analyses of brain regions using neuropathological, neurochemical, neuropharmacological and gene expression assays.

  10. Optogenetic manipulation of anatomical re-entry by light-guided generation of a reversible local conduction block.

    PubMed

    Watanabe, Masaya; Feola, Iolanda; Majumder, Rupamanjari; Jangsangthong, Wanchana; Teplenin, Alexander S; Ypey, Dirk L; Schalij, Martin J; Zeppenfeld, Katja; de Vries, Antoine A F; Pijnappels, Daniël A

    2017-03-01

    Anatomical re-entry is an important mechanism of ventricular tachycardia, characterized by circular electrical propagation in a fixed pathway. It's current investigative and therapeutic approaches are non-biological, rather unspecific (drugs), traumatizing (electrical shocks), or irreversible (ablation). Optogenetics is a new biological technique that allows reversible modulation of electrical function with unmatched spatiotemporal precision using light-gated ion channels. We therefore investigated optogenetic manipulation of anatomical re-entry in ventricular cardiac tissue. Transverse, 150-μm-thick ventricular slices, obtained from neonatal rat hearts, were genetically modified with lentiviral vectors encoding Ca2+-translocating channelrhodopsin (CatCh), a light-gated depolarizing ion channel, or enhanced yellow fluorescent protein (eYFP) as control. Stable anatomical re-entry was induced in both experimental groups. Activation of CatCh was precisely controlled by 470-nm patterned illumination, while the effects on anatomical re-entry were studied by optical voltage mapping. Regional illumination in the pathway of anatomical re-entry resulted in termination of arrhythmic activity only in CatCh-expressing slices by establishing a local and reversible, depolarization-induced conduction block in the illuminated area. Systematic adjustment of the size of the light-exposed area in the re-entrant pathway revealed that re-entry could be terminated by either wave collision or extinction, depending on the depth (transmurality) of illumination. In silico studies implicated source-sink mismatches at the site of subtransmural conduction block as an important factor in re-entry termination. Anatomical re-entry in ventricular tissue can be manipulated by optogenetic induction of a local and reversible conduction block in the re-entrant pathway, allowing effective re-entry termination. These results provide distinctively new mechanistic insight into re-entry termination and a novel perspective for cardiac arrhythmia management. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  11. Antagonism of Sigma-1 Receptors Blocks Compulsive-Like Eating

    PubMed Central

    Cottone, Pietro; Wang, Xiaofan; Park, Jin Won; Valenza, Marta; Blasio, Angelo; Kwak, Jina; Iyer, Malliga R; Steardo, Luca; Rice, Kenner C; Hayashi, Teruo; Sabino, Valentina

    2012-01-01

    Binge eating disorder is an addiction-like disorder characterized by episodes of rapid and excessive food consumption within discrete periods of time which occur compulsively despite negative consequences. This study was aimed at determining whether antagonism of Sigma-1 receptors (Sig-1Rs) blocked compulsive-like binge eating. We trained male wistar rats to obtain a sugary, highly palatable diet (Palatable group) or a regular chow diet (Chow control group), for 1 h a day under fixed ratio 1 operant conditioning. Following intake stabilization, we evaluated the effects of the selective Sig-1R antagonist BD-1063 on food responding. Using a light/dark conflict test, we also tested whether BD-1063 could block the time spent and the food eaten in an aversive, open compartment, where the palatable diet was offered. Furthermore, we measured Sig-1R mRNA and protein expression in several brain areas of the two groups, 24 h after the last binge session. Palatable rats rapidly developed binge-like eating, escalating the 1 h intake by four times, and doubling the eating rate and the regularity of food responding, compared to Chow rats. BD-1063 dose-dependently reduced binge-like eating and the regularity of food responding, and blocked the increased eating rate in Palatable rats. In the light/dark conflict test, BD-1063 antagonized the increased time spent in the aversive compartment and the increased intake of the palatable diet, without affecting motor activity. Finally, Palatable rats showed reduced Sig-1R mRNA expression in prefrontal and anterior cingulate cortices, and a two-fold increase in Sig-1R protein expression in anterior cingulate cortex compared to control Chow rats. These findings suggest that the Sig-1R system may contribute to the neurobiological adaptations driving compulsive-like eating, opening new avenues of investigation towards pharmacologically treating binge eating disorder. PMID:22713906

  12. Block entropy and quantum phase transition in the anisotropic Kondo necklace model

    NASA Astrophysics Data System (ADS)

    Mendoza-Arenas, J. J.; Franco, R.; Silva-Valencia, J.

    2010-06-01

    We study the von Neumann block entropy in the Kondo necklace model for different anisotropies η in the XY interaction between conduction spins using the density matrix renormalization group method. It was found that the block entropy presents a maximum for each η considered, and, comparing it with the results of the quantum criticality of the model based on the behavior of the energy gap, we observe that the maximum block entropy occurs at the quantum critical point between an antiferromagnetic and a Kondo singlet state, so this measure of entanglement is useful for giving information about where a quantum phase transition occurs in this model. We observe that the block entropy also presents a maximum at the quantum critical points that are obtained when an anisotropy Δ is included in the Kondo exchange between localized and conduction spins; when Δ diminishes for a fixed value of η, the critical point increases, favoring the antiferromagnetic phase.

  13. Joint detection and tracking of size-varying infrared targets based on block-wise sparse decomposition

    NASA Astrophysics Data System (ADS)

    Li, Miao; Lin, Zaiping; Long, Yunli; An, Wei; Zhou, Yiyu

    2016-05-01

    The high variability of target size makes small target detection in Infrared Search and Track (IRST) a challenging task. A joint detection and tracking method based on block-wise sparse decomposition is proposed to address this problem. For detection, the infrared image is divided into overlapped blocks, and each block is weighted on the local image complexity and target existence probabilities. Target-background decomposition is solved by block-wise inexact augmented Lagrange multipliers. For tracking, label multi-Bernoulli (LMB) tracker tracks multiple targets taking the result of single-frame detection as input, and provides corresponding target existence probabilities for detection. Unlike fixed-size methods, the proposed method can accommodate size-varying targets, due to no special assumption for the size and shape of small targets. Because of exact decomposition, classical target measurements are extended and additional direction information is provided to improve tracking performance. The experimental results show that the proposed method can effectively suppress background clutters, detect and track size-varying targets in infrared images.

  14. Determination of Protein Expression Level in Cultured Cells by Immunocytochemistry on Paraffin-embedded Cell Blocks.

    PubMed

    Poojan, Shiv; Kim, Han-Seong; Yoon, Ji-Woon; Sim, Hye Won; Hong, Kyeong-Man

    2018-05-20

    Immunofluorescent staining is currently the method of choice for determination of protein expression levels in cell-culture systems when morphological information is also necessary. The protocol of immunocytochemical staining on paraffin-embedded cell blocks, presented herein, is an excellent alternative to immunofluorescent staining on non-paraffin-embedded fixed cells. In this protocol, a paraffin cell block from HeLa cells was prepared using the thromboplastin-plasma method, and immunocytochemistry was performed for the evaluation of two proliferation markers, CKAP2 and Ki-67. The nuclei and cytoplasmic morphology of the HeLa cells were well preserved in the cell-block slides. At the same time, the CKAP2 and Ki-67 staining patterns in the immunocytochemistry were quite similar to those in immunohistochemical staining in paraffin cancer tissues. With modified cell-culture conditions, including pre-incubation of HeLa cells under serum-free conditions, the effect could be evaluated while preserving architectural information. In conclusion, immunocytochemistry on paraffin-embedded cell blocks is an excellent alternative to immunofluorescent staining.

  15. Rubidium atomic frequency standards for GPS Block IIR

    NASA Technical Reports Server (NTRS)

    Riley, William J.

    1990-01-01

    The Rubidium Atomic Frequency Standards (RAFS) were provided for the GPS Block IIR NAVSTAR satellites. These satellites will replenish and upgrade the space segment of the Global Positioning System in the mid 1990s. The GPS RAFS Rb clocks are the latest generation of the high-performance rubidium frequency standards. They offer an aging rate in the low pp 10(exp 14)/day range and a drift-corrected 1-day stability in the low pp 10(exp 14) range. The Block IIR version of these devices will have improved performance, higher reliability, smaller size, and greater radiation hardness. The GPS Block IIR atomic clocks have a natural frequency configuration whereby they output a frequency of about 13.4 MHz that is a submultiple of the atomic resonance of Rb (or Cs). The RAFS operates at a low, fixed C-field for increased stability. The GPS Block IIR RAFS design, including the changes and improvements made, and the test results obtained are described.

  16. Sinus floor elevation with a crestal approach using a press-fit bone block: a case series.

    PubMed

    Isidori, M; Genty, C; David-Tchouda, S; Fortin, T

    2015-09-01

    This prospective study aimed to provide detailed clinical information on a sinus augmentation procedure, i.e., transcrestal sinus floor elevation with a bone block using the press-fit technique. A bone block is harvested with a trephine burr to obtain a cylinder. This block is inserted into the antrum via a crestal approach after creation of a circular crestal window. Thirty-three patients were treated with a fixed prosthesis supported by implants placed on 70 cylindrical bone blocks. The mean bone augmentation was 6.08±2.87 mm, ranging from 0 to 12.7 mm. Only one graft failed before implant placement. During surgery and the subsequent observation period, no complications were recorded, one implant was lost, and no infection or inflammation was observed. This proof-of-concept study suggests that the use of a bone block inserted into the sinus cavity via a crestal approach can be an alternative to the sinus lift procedure with the creation of a lateral window. It reduces the duration of surgery, cost of treatment, and overall discomfort. Copyright © 2015. Published by Elsevier Ltd.

  17. The relationship between functional sciatic nerve block duration and the rate of release of lidocaine from a controlled-release matrix.

    PubMed

    Gerner, Peter; Wang, Chi-Fei; Lee, Byung-Sang; Suzuki, Suzuko; Degirolami, Umberto; Gandhi, Ankur; Knaack, David; Strichartz, Gary

    2010-07-01

    Nerve blocks of long duration are often desirable in perioperative and postoperative situations. The relationship between the duration of such blocks and the rate at which a local anesthetic is released is important to know for developing a localized drug delivery system that will optimize block duration. Lidocaine concentration was varied in 1 series of formulations (OSB-L) containing a constant amount of release rate modifier. In another series (OST-R), the release rate modifier was varied while the lidocaine content was held constant. Release kinetics were measured in vitro and correlated to the in vivo duration of antinociceptive and motor block effects when the formulation was implanted next to the rat sciatic nerve. In parallel studies, rats receiving different formulations of slow-release lidocaine were fixed by intracardiac perfusion with 4% paraformaldehyde and nerve-muscle tissue taken for histopathological analysis. In this study, we have demonstrated that the most important variable for effecting functional nerve block, i.e., the blockade of impulses in the relevant fibers of the sciatic nerve, is the rate of lidocaine release at that time. For the OSB-L formulations (lidocaine concentrations of 1.875%, 3.75%, 7.5%, and 15% at a constant release rate modifier of 5%), the average in vitro release rates at 50% recovery of motor block and nociceptive block were 0.91 +/- 0.28 and 1.75 +/- 0.61 mg/h, respectively. For the OST-R formulations (16% lidocaine with release rate modifier concentrations of 1.875%, 3.75%, 7.5%, and 15%), the average in vitro release rates at 50% recovery of motor block and nociceptive block were 2.33 +/- 1.39 and 4.34 +/- 1.09 mg/h, respectively. The OSB-L formulations showed a dose-dependent increase in block duration proportional to an increase in initial lidocaine concentration, whereas the OST-R formulations showed a nonmonotonic relationship between release rate modifier concentration and block duration. The histopathological studies at 24 hours, 3, 5, or 7 days, and 4 weeks after the implantation revealed inflammatory reactions with degrees correlated with lidocaine content, but limited to the connective tissue and muscle immediately surrounding the implanted material. Despite these observed inflammatory reactions, nociceptive and motor block function returned to normal, preimplantation values in all animals. Increasing initial lidocaine content proportionately increased the duration of functional sciatic nerve block. However, decreasing the release rate per se does not give a proportional increase in block duration. Instead, there seems to be an optimal, intermediate release rate for achieving the maximum duration of block.

  18. Knotless anchors with sutures external to the anchor body may be at risk for suture cutting through osteopenic bone

    PubMed Central

    Ono, Y.; Woodmass, J. M.; Nelson, A. A.; Boorman, R. S.; Thornton, G. M.

    2016-01-01

    Objectives This study evaluated the mechanical performance, under low-load cyclic loading, of two different knotless suture anchor designs: sutures completely internal to the anchor body (SpeedScrew) and sutures external to the anchor body and adjacent to bone (MultiFIX P). Methods Using standard suture loops pulled in-line with the rotator cuff (approximately 60°), anchors were tested in cadaveric bone and foam blocks representing normal to osteopenic bone. Mechanical testing included preloading to 10 N and cyclic loading for 500 cycles from 10 N to 60 N at 60 mm/min. The parameters evaluated were initial displacement, cyclic displacement and number of cycles and load at 3 mm displacement relative to preload. Video recording throughout testing documented the predominant source of suture displacement and the distance of ‘suture cutting through bone’. Results In cadaveric bone and foam blocks, MultiFIX P anchors had significantly greater initial displacement, and lower number of cycles and lower load at 3 mm displacement than SpeedScrew anchors. Video analysis revealed ‘suture cutting through bone’ as the predominant source of suture displacement in cadaveric bone (qualitative) and greater ‘suture cutting through bone’ comparing MultiFIX P with SpeedScrew anchors in foam blocks (quantitative). The greater suture displacement in MultiFIX P anchors was predominantly from suture cutting through bone, which was enhanced in an osteopenic bone model. Conclusions Anchors with sutures external to the anchor body are at risk for suture cutting through bone since the suture eyelet is at the distal tip of the implant and the suture directly abrades against the bone edge during cyclic loading. Suture cutting through bone may be a significant source of fixation failure, particularly in osteopenic bone. Cite this article: Y. Ono, J. M. Woodmass, A. A. Nelson, R. S. Boorman, G. M. Thornton, I. K. Y. Lo. Knotless anchors with sutures external to the anchor body may be at risk for suture cutting through osteopenic bone. Bone Joint Res 2016;5:269–275. DOI: 10.1302/2046-3758.56.2000535. PMID:27357383

  19. Knotless anchors with sutures external to the anchor body may be at risk for suture cutting through osteopenic bone.

    PubMed

    Ono, Y; Woodmass, J M; Nelson, A A; Boorman, R S; Thornton, G M; Lo, I K Y

    2016-06-01

    This study evaluated the mechanical performance, under low-load cyclic loading, of two different knotless suture anchor designs: sutures completely internal to the anchor body (SpeedScrew) and sutures external to the anchor body and adjacent to bone (MultiFIX P). Using standard suture loops pulled in-line with the rotator cuff (approximately 60°), anchors were tested in cadaveric bone and foam blocks representing normal to osteopenic bone. Mechanical testing included preloading to 10 N and cyclic loading for 500 cycles from 10 N to 60 N at 60 mm/min. The parameters evaluated were initial displacement, cyclic displacement and number of cycles and load at 3 mm displacement relative to preload. Video recording throughout testing documented the predominant source of suture displacement and the distance of 'suture cutting through bone'. In cadaveric bone and foam blocks, MultiFIX P anchors had significantly greater initial displacement, and lower number of cycles and lower load at 3 mm displacement than SpeedScrew anchors. Video analysis revealed 'suture cutting through bone' as the predominant source of suture displacement in cadaveric bone (qualitative) and greater 'suture cutting through bone' comparing MultiFIX P with SpeedScrew anchors in foam blocks (quantitative). The greater suture displacement in MultiFIX P anchors was predominantly from suture cutting through bone, which was enhanced in an osteopenic bone model. Anchors with sutures external to the anchor body are at risk for suture cutting through bone since the suture eyelet is at the distal tip of the implant and the suture directly abrades against the bone edge during cyclic loading. Suture cutting through bone may be a significant source of fixation failure, particularly in osteopenic bone.Cite this article: Y. Ono, J. M. Woodmass, A. A. Nelson, R. S. Boorman, G. M. Thornton, I. K. Y. Lo. Knotless anchors with sutures external to the anchor body may be at risk for suture cutting through osteopenic bone. Bone Joint Res 2016;5:269-275. DOI: 10.1302/2046-3758.56.2000535. © 2016 Lo et al.

  20. Fatigue limit of monolithic Y-TZP three-unit-fixed dental prostheses: Effect of grinding at the gingival zone of the connector.

    PubMed

    Amaral, Marina; Villefort, Regina F; Melo, Renata Marques; Pereira, Gabriel K R; Zhang, Yu; Valandro, Luiz Felipe; Bottino, Marco Antonio

    2017-08-01

    To determine the fatigue limits of three-unit monolithic zirconia fixed dental prosthesis (FDPs) before and after grinding of the gingival areas of connectors with diamond burs. FDPs were milled from pre-sintered blocks of zirconia simulating the absence of the first mandibular molar. Half of the specimens were subjected to grinding, simulating clinical adjustment, and all of them were subjected to glazing procedure. Additional specimens were manufactured for roughness analysis. FDPs were adhesively cemented onto glass-fiber reinforced epoxy resin abutments. Fatigue limits and standard deviations were obtained using a staircase fatigue method (n=20, 100,000 loading cycles/5Hz). The initial test load was 70% of the mean load-to-fracture (n=3) and load increments were 5% of the initial test load for both the control and ground specimens. Data were compared by Student's T-test (α≤0.05). Both the control and ground groups exhibited similar values of load-to-fracture and fatigue limits. Neither the surface treatments nor ageing affected the surface roughness of the specimens. The damage induced by grinding with fine-grit diamond bur in the gingival area of the connectors did not decrease the fatigue limit of the three-unit monolithic zirconia FDP. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Analysis of blocking probability for OFDM-based variable bandwidth optical network

    NASA Astrophysics Data System (ADS)

    Gong, Lei; Zhang, Jie; Zhao, Yongli; Lin, Xuefeng; Wu, Yuyao; Gu, Wanyi

    2011-12-01

    Orthogonal Frequency Division Multiplexing (OFDM) has recently been proposed as a modulation technique. For optical networks, because of its good spectral efficiency, flexibility, and tolerance to impairments, optical OFDM is much more flexible compared to traditional WDM systems, enabling elastic bandwidth transmissions, and optical networking is the future trend of development. In OFDM-based optical network the research of blocking rate has very important significance for network assessment. Current research for WDM network is basically based on a fixed bandwidth, in order to accommodate the future business and the fast-changing development of optical network, our study is based on variable bandwidth OFDM-based optical networks. We apply the mathematical analysis and theoretical derivation, based on the existing theory and algorithms, research blocking probability of the variable bandwidth of optical network, and then we will build a model for blocking probability.

  2. Maximum volume cuboids for arbitrarily shaped in-situ rock blocks as determined by discontinuity analysis—A genetic algorithm approach

    NASA Astrophysics Data System (ADS)

    Ülker, Erkan; Turanboy, Alparslan

    2009-07-01

    The block stone industry is one of the main commercial use of rock. The economic potential of any block quarry depends on the recovery rate, which is defined as the total volume of useful rough blocks extractable from a fixed rock volume in relation to the total volume of moved material. The natural fracture system, the rock type(s) and the extraction method used directly influence the recovery rate. The major aims of this study are to establish a theoretical framework for optimising the extraction process in marble quarries for a given fracture system, and for predicting the recovery rate of the excavated blocks. We have developed a new approach by taking into consideration only the fracture structure for maximum block recovery in block quarries. The complete model uses a linear approach based on basic geometric features of discontinuities for 3D models, a tree structure (TS) for individual investigation and finally a genetic algorithm (GA) for the obtained cuboid volume(s). We tested our new model in a selected marble quarry in the town of İscehisar (AFYONKARAHİSAR—TURKEY).

  3. Future perspectives in target-specific immunotherapies of myasthenia gravis

    PubMed Central

    Dalakas, Marinos C.

    2015-01-01

    Myasthenia gravis (MG) is an autoimmune disease caused by complement-fixing antibodies against acetylcholine receptors (AChR); antigen-specific CD4+ T cells, regulatory T cells (Tregs) and T helper (Th) 17+ cells are essential in antibody production. Target-specific therapeutic interventions should therefore be directed against antibodies, B cells, complement and molecules associated with T cell signaling. Even though the progress in the immunopathogenesis of the disease probably exceeds any other autoimmune disorder, MG is still treated with traditional drugs or procedures that exert a non-antigen specific immunosuppression or immunomodulation. Novel biological agents currently on the market, directed against the following molecular pathways, are relevant and specific therapeutic targets that can be tested in MG: (a) T cell intracellular signaling molecules, such as anti-CD52, anti-interleukin (IL) 2 receptors, anti- costimulatory molecules, and anti-Janus tyrosine kinases (JAK1, JAK3) that block the intracellular cascade associated with T-cell activation; (b) B cells and their trophic factors, directed against key B-cell molecules; (c) complement C3 or C5, intercepting the destructive effect of complement-fixing antibodies; (d) cytokines and cytokine receptors, such as those targeting IL-6 which promotes antibody production and IL-17, or the p40 subunit of IL-12/1L-23 that affect regulatory T cells; and (e) T and B cell transmigration molecules associated with lymphocyte egress from the lymphoid organs. All drugs against these molecular pathways require testing in controlled trials, although some have already been tried in small case series. Construction of recombinant AChR antibodies that block binding of the pathogenic antibodies, thereby eliminating complement and antibody-depended-cell-mediated cytotoxicity, are additional novel molecular tools that require exploration in experimental MG. PMID:26600875

  4. Detection of SYT-SSX mutant transcripts in formalin-fixed paraffin-embedded sarcoma tissues using one-step reverse transcriptase real-time PCR.

    PubMed

    Norlelawati, A T; Mohd Danial, G; Nora, H; Nadia, O; Zatur Rawihah, K; Nor Zamzila, A; Naznin, M

    2016-04-01

    Synovial sarcoma (SS) is a rare cancer and accounts for 5-10% of adult soft tissue sarcomas. Making an accurate diagnosis is difficult due to the overlapping histological features of SS with other types of sarcomas and the non-specific immunohistochemistry profile findings. Molecular testing is thus considered necessary to confirm the diagnosis since more than 90% of SS cases carry the transcript of t(X;18)(p11.2;q11.2). The purpose of this study is to diagnose SS at molecular level by testing for t(X;18) fusion-transcript expression through One-step reverse transcriptase real-time Polymerase Chain Reaction (PCR). Formalin-fixed paraffin-embedded tissue blocks of 23 cases of soft tissue sarcomas, which included 5 and 8 cases reported as SS as the primary diagnosis and differential diagnosis respectively, were retrieved from the Department of Pathology, Tengku Ampuan Afzan Hospital, Kuantan, Pahang. RNA was purified from the tissue block sections and then subjected to One-step reverse transcriptase real-time PCR using sequence specific hydrolysis probes for simultaneous detection of either SYT-SSX1 or SYT-SSX2 fusion transcript. Of the 23 cases, 4 cases were found to be positive for SYT-SSX fusion transcript in which 2 were diagnosed as SS whereas in the 2 other cases, SS was the differential diagnosis. Three cases were excluded due to failure of both amplification assays SYT-SSX and control β-2-microglobulin. The remaining 16 cases were negative for the fusion transcript. This study has shown that the application of One-Step reverse transcriptase real time PCR for the detection SYT-SSX transcript is feasible as an aid in confirming the diagnosis of synovial sarcoma.

  5. Controller design for global fixed-time synchronization of delayed neural networks with discontinuous activations.

    PubMed

    Wang, Leimin; Zeng, Zhigang; Hu, Junhao; Wang, Xiaoping

    2017-03-01

    This paper addresses the controller design problem for global fixed-time synchronization of delayed neural networks (DNNs) with discontinuous activations. To solve this problem, adaptive control and state feedback control laws are designed. Then based on the two controllers and two lemmas, the error system is proved to be globally asymptotically stable and even fixed-time stable. Moreover, some sufficient and easy checked conditions are derived to guarantee the global synchronization of drive and response systems in fixed time. It is noted that the settling time functional for fixed-time synchronization is independent on initial conditions. Our fixed-time synchronization results contain the finite-time results as the special cases by choosing different values of the two controllers. Finally, theoretical results are supported by numerical simulations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Fixed or removable function appliances for Class II malocclusions.

    PubMed

    Madurantakam, Parthasarathy

    2016-06-01

    Data sourcesEmbase, Cochrane Central Register of Controlled Trials, Medline (Pubmed), Web of Science, Google Scholar, Scopus, LILACS database and bibliographies of clinical trials encountered during search. There was no restriction on language or date during search.Study selectionRandomised Controlled Trials (RCTs) and Controlled Clinical Trials (CCT) in patients with Class II malocclusions that compared at least one fixed functional appliance with at least one removable functional appliance (RFA) in children below 16 years of age. Primary outcomes were clinical and lateral cephalometric measurements and the duration of treatment. Secondary outcomes included patient experiences of treatment, quality of life measures and harms arising during treatment as well as costs of both treatments.Data extraction and synthesisThe titles and abstracts of all studies identified through the search were assessed independently and in duplicate by two review authors. Disagreements about included studies were resolved through discussion with the third author. Heterogeneity was assessed using customised forms and risk of bias using a Cochrane Collaboration tool. A meta-analysis was planned for studies at low risk of bias with similar comparisons reporting the same outcome.ResultsTwo RCTs and two CCTs that met the inclusion/exclusion criteria were included in the final analysis. Risk of bias assessment indicated three trials were at high risk while one was unclear. Consequently, the included trials were deemed to be inappropriate for meta-analysis (MA).Two studies with 282 participants evaluated Twin Block with fixed Herbst appliance and reported significant improvements in anterior-posterior skeletal discrepancy, mandibular length and reduction of overjet with both appliances. While one study reported significantly shorter treatment duration in Herbst appliance, the other study did not find any difference. Herbst appliance had better compliance, less dropouts but more emergency visits.One trial that compared activator appliance with Twin Force Bite Corrector found significantly shorter time with the fixed appliance. However, effective length and sagittal positioning of the mandible was not different between the groups.One trial comparing activator with Forsus FRZ reported enhanced mandibular growth and restrained maxillary growth with both the appliances. While activator appliance was associated with increased posterior facial height, Forsus significantly rotated the occlusal plane.ConclusionsLimited available evidence indicates that both fixed and removable functional appliances are effective in reducing overjet in growing children. However, there is insufficient evidence to differentiate between the two types with respect to biological (skeletal and dental) effects or patient experiences.

  7. An Embodiment Perspective on Number-Space Mapping in 3.5-Year-Old Dutch Children.

    PubMed

    van 't Noordende, Jaccoline E; Volman, M Chiel J M; Leseman, Paul P M; Kroesbergen, Evelyn H

    2017-01-01

    Previous research suggests that block adding, subtracting and counting direction are early forms of number-space mapping. In this study, an embodiment perspective on these skills was taken. Embodiment theory assumes that cognition emerges through sensory-motor interaction with the environment. In line with this assumption, it was investigated if counting and adding/subtracting direction in young children is related to the hand they use during task performance. Forty-eight 3.5-year-old children completed a block adding, subtracting and counting task. They had to add and remove a block from a row of three blocks and count a row of five blocks. Adding, subtracting and counting direction were related to the hand the children used for task performance. Most children who used their right hand added, removed and started counting the blocks at the right side of the row. Most children who used their left hand added, removed and started counting the blocks at the left side of the row. It can be concluded that number-space mapping, as measured by direction of adding, subtracting and counting blocks, in young children is embodied: It is not fixed, but is related to the situation. © 2016 The Authors Infant and Child Development Published by John Wiley & Sons, Ltd.

  8. Effect of local anesthetic dilution on the onset time and duration of double-injection sciatic nerve block: a prospective, randomized, blinded evaluation.

    PubMed

    Cappelleri, Gianluca; Ambrosoli, Andrea Luigi; Turconi, Stefania; Gemma, Marco; Ricci, Erika Basso; Cornaggia, Gabriele

    2014-08-01

    Among the various factors influencing the success rate, onset time, and duration of peripheral nerve blocks, the role of local anesthetics concentration remains uncertain. In this prospective, randomized, single-blinded study, we evaluated whether varying the dilution of a fixed dose of mepivacaine solution influenced onset time and duration of sciatic nerve block. Ninety ASA physical status I to II patients scheduled for foot surgery were randomly allocated to receive a double-injection Labat sciatic nerve block with 12 mL mepivacaine 2% (group concentration I = 45 patients) or 24 mL of mepivacaine 1% (group volume II = 45 patients). The nerve stimulator was initially set at 2 Hz, 0.1 millisecond, 1 mA. The total amount of local anesthetic (240 mg) was kept constant and equally divided between the peroneal and tibial nerves. All patients also received an ultrasound-guided popliteal sciatic nerve catheter for postoperative analgesia. Times to readiness for surgery, performance, and offset of local anesthetic were recorded. Our primary end point was to determine a possible difference in offset time between groups. Continuous variables were expressed as median (IQR) and compared with the Wilcoxon-Mann-Whitney U test; WMWodds are reported together with their 95% confidence interval. The overall success rate of sciatic nerve block was 99%. Time of performance was shorter in group I, 120 seconds (90-150 seconds), than that in group II, 150 seconds (120-180 seconds) (P = 0.0048; WMWodds 2.26 [1.35-4.34]). The onset time of sensory and motor sciatic nerve block was 4 minutes (2-9 minutes) in group I and 6 minutes (4-10 minutes) in group II (P = 0.41; WMWodds 1.21 [0.77-1.95]), while the duration of sensory block was 235 minutes (203-250 minutes) in group I, and 240 minutes (218-247 minutes) in group II respectively (P = 0.51; WMWodds 1.20 [0.69-2.16]). We found no evidence that varying volume and concentration while maintaining a fixed total dose of mepivacaine alters the onset time and duration of double-injection sciatic nerve block. Considering our WMWodds results, possible differences in onset time and duration comparable to differences in the performance time between groups cannot be excluded.

  9. Performance of an Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy

    NASA Technical Reports Server (NTRS)

    Newman, Kevin; Belikov, Ruslan; Pluzhnik, Eugene; Balasubramanian, Kunjithapatham; Wilson, Dan

    2014-01-01

    Coronagraph technology combined with wavefront control is close to achieving the contrast and inner working angle requirements in the lab necessary to observe the faint signal of an Earth-like exoplanet in monochromatic light. An important remaining technological challenge is to achieve high contrast in broadband light. Coronagraph bandwidth is largely limited by chromaticity of the focal plane mask, which is responsible for blocking the stellar PSF. The size of a stellar PSF scales linearly with wavelength; ideally, the size of the focal plane mask would also scale with wavelength. A conventional hard-edge focal plane mask has a fixed size, normally sized for the longest wavelength in the observational band to avoid starlight leakage. The conventional mask is oversized for shorter wavelengths and blocks useful discovery space. Recently we presented a solution to the size chromaticity challenge with a focal plane mask designed to scale its effective size with wavelength. In this paper, we analyze performance of the achromatic size-scaling focal plane mask within a Phase Induced Amplitude Apodization (PIAA) coronagraph. We present results from wavefront control around the achromatic focal plane mask, and demonstrate the size-scaling effect of the mask with wavelength. The edge of the dark zone, and therefore the inner working angle of the coronagraph, scale with wavelength. The achromatic mask enables operation in a wider band of wavelengths compared with a conventional hard-edge occulter.

  10. Six-flow operations for catalyst development in Fischer-Tropsch synthesis: Bridging the gap between high-throughput experimentation and extensive product evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sartipi, Sina, E-mail: S.Sartipi@tudelft.nl, E-mail: J.Gascon@tudelft.nl; Jansma, Harrie; Bosma, Duco

    2013-12-15

    Design and operation of a “six-flow fixed-bed microreactor” setup for Fischer-Tropsch synthesis (FTS) is described. The unit consists of feed and mixing, flow division, reaction, separation, and analysis sections. The reactor system is made of five heating blocks with individual temperature controllers, assuring an identical isothermal zone of at least 10 cm along six fixed-bed microreactor inserts (4 mm inner diameter). Such a lab-scale setup allows running six experiments in parallel, under equal feed composition, reaction temperature, and conditions of separation and analysis equipment. It permits separate collection of wax and liquid samples (from each flow line), allowing operation with highmore » productivities of C5+ hydrocarbons. The latter is crucial for a complete understanding of FTS product compositions and will represent an advantage over high-throughput setups with more than ten flows where such instrumental considerations lead to elevated equipment volume, cost, and operation complexity. The identical performance (of the six flows) under similar reaction conditions was assured by testing a same catalyst batch, loaded in all microreactors.« less

  11. An Evaluation of the Gap Sizes of 3-Unit Fixed Dental Prostheses Milled from Sintering Metal Blocks.

    PubMed

    Jung, Jae-Kwan

    2017-01-01

    This study assessed the clinical acceptability of sintering metal-fabricated 3-unit fixed dental prostheses (FDPs) based on gap sizes. Ten specimens were prepared on research models by milling sintering metal blocks or by the lost-wax technique (LWC group). Gap sizes were assessed at 12 points per abutment (premolar and molar), 24 points per specimen (480 points in a total in 20 specimens). The measured points were categorized as marginal, axial wall, and occlusal for assessment in a silicone replica. The silicone replica was cut through the mesiodistal and buccolingual center. The four sections were magnified at 160x, and the thickness of the light body silicone was measured to determine the gap size, and gap size means were compared. For the premolar part, the mean (standard deviation) gap size was nonsignificantly ( p = 0.139) smaller in the SMB group (68.6 ± 35.6  μ m) than in the LWC group (69.6 ± 16.9  μ m). The mean molar gap was nonsignificantly smaller ( p = 0.852) in the LWC (73.9 ± 25.6  μ m) than in the SMB (78.1 ± 37.4  μ m) group. The gap sizes were similar between the two groups. Because the gap sizes were within the previously proposed clinically accepted limit, FDPs prepared by sintered metal block milling are clinically acceptable.

  12. An Evaluation of the Gap Sizes of 3-Unit Fixed Dental Prostheses Milled from Sintering Metal Blocks

    PubMed Central

    2017-01-01

    This study assessed the clinical acceptability of sintering metal-fabricated 3-unit fixed dental prostheses (FDPs) based on gap sizes. Ten specimens were prepared on research models by milling sintering metal blocks or by the lost-wax technique (LWC group). Gap sizes were assessed at 12 points per abutment (premolar and molar), 24 points per specimen (480 points in a total in 20 specimens). The measured points were categorized as marginal, axial wall, and occlusal for assessment in a silicone replica. The silicone replica was cut through the mesiodistal and buccolingual center. The four sections were magnified at 160x, and the thickness of the light body silicone was measured to determine the gap size, and gap size means were compared. For the premolar part, the mean (standard deviation) gap size was nonsignificantly (p = 0.139) smaller in the SMB group (68.6 ± 35.6 μm) than in the LWC group (69.6 ± 16.9 μm). The mean molar gap was nonsignificantly smaller (p = 0.852) in the LWC (73.9 ± 25.6 μm) than in the SMB (78.1 ± 37.4 μm) group. The gap sizes were similar between the two groups. Because the gap sizes were within the previously proposed clinically accepted limit, FDPs prepared by sintered metal block milling are clinically acceptable. PMID:28246605

  13. Background staining of visualization systems in immunohistochemistry: comparison of the Avidin-Biotin Complex system and the EnVision+ system.

    PubMed

    Vosse, Bettine A H; Seelentag, Walter; Bachmann, Astrid; Bosman, Fred T; Yan, Pu

    2007-03-01

    The aim of this study was to evaluate specific immunostaining and background staining in formalin-fixed, paraffin-embedded human tissues with the 2 most frequently used immunohistochemical detection systems, Avidin-Biotin-Peroxidase (ABC) and EnVision+. A series of fixed tissues, including breast, colon, kidney, larynx, liver, lung, ovary, pancreas, prostate, stomach, and tonsil, was used in the study. Three monoclonal antibodies, 1 against a nuclear antigen (Ki-67), 1 against a cytoplasmic antigen (cytokeratin), and 1 against a cytoplasmic and membrane-associated antigen and a polyclonal antibody against a nuclear and cytoplasmic antigen (S-100) were selected for these studies. When the ABC system was applied, immunostaining was performed with and without blocking of endogenous avidin-binding activity. The intensity of specific immunostaining and the percentage of stained cells were comparable for the 2 detection systems. The use of ABC caused widespread cytoplasmic and rare nuclear background staining in a variety of normal and tumor cells. A very strong background staining was observed in colon, gastric mucosa, liver, and kidney. Blocking avidin-binding capacity reduced background staining, but complete blocking was difficult to attain. With the EnVision+ system no background staining occurred. Given the efficiency of the detection, equal for both systems or higher with EnVision+, and the significant background problem with ABC, we advocate the routine use of the EnVision+ system.

  14. An application of software design and documentation language. [Galileo spacecraft command and data subsystem

    NASA Technical Reports Server (NTRS)

    Callender, E. D.; Clarkson, T. B.; Frasier, C. E.

    1980-01-01

    The software design and documentation language (SDDL) is a general purpose processor to support a lanugage for the description of any system, structure, concept, or procedure that may be presented from the viewpoint of a collection of hierarchical entities linked together by means of binary connections. The language comprises a set of rules of syntax, primitive construct classes (module, block, and module invocation), and language control directives. The result is a language with a fixed grammar, variable alphabet and punctuation, and an extendable vocabulary. The application of SDDL to the detailed software design of the Command Data Subsystem for the Galileo Spacecraft is discussed. A set of constructs was developed and applied. These constructs are evaluated and examples of their application are considered.

  15. Mechanical properties and ultrastructural characteristics of a glass fiber-reinforced composite.

    PubMed

    García Barbero, Alvaro Enrique; Vera González, Vicente; García Barbero, Ernesto; Aliaga Vera, Ignacio

    2015-06-01

    To examine the ultrastructural characteristics of a fiber-reinforced composite (FRC) and its behavior in vitro as a framework for fixed partial dentures (FPDs). A total of 40 specimens were prepared using extracted teeth fixed in methacrylate blocks as supports for the FPD, then the specimens were divided into four groups depending on whether a retaining box was used to fix the FPD to the support teeth, and on whether a composite pontic was assembled on top of the fibers. Fracture testing was performed in a universal testing machine (1 mm/minute). Fracture strength values and failure types were statistically compared for each group. Using retaining boxes did not improve the mechanical behavior of the restorative system. The weakest element of the system was the composite tooth constructed on top of the FRC.

  16. Temperature Values Variability in Piezoelectric Implant Site Preparation: Differences between Cortical and Corticocancellous Bovine Bone.

    PubMed

    Lamazza, Luca; Garreffa, Girolamo; Laurito, Domenica; Lollobrigida, Marco; Palmieri, Luigi; De Biase, Alberto

    2016-01-01

    Various parameters can influence temperature rise and detection during implant site preparation. The aim of this study is to investigate local temperature values in cortical and corticocancellous bovine bone during early stages of piezoelectric implant site preparation. 20 osteotomies were performed using a diamond tip (IM1s, Mectron Medical Technology, Carasco, Italy) on two different types of bovine bone samples, cortical and corticocancellous, respectively. A standardized protocol was designed to provide constant working conditions. Temperatures were measured in real time at a fixed position by a fiber optic thermometer. Significantly higher drilling time (154.90 sec versus 99.00 sec; p < 0.0001) and temperatures (39.26°C versus 34.73°C; p = 0.043) were observed in the cortical group compared to the corticocancellous group. A remarkable variability of results characterized the corticocancellous blocks as compared to the blocks of pure cortical bone. Bone samples can influence heat generation during in vitro implant site preparation. When compared to cortical bone, corticocancellous samples present more variability in temperature values. Even controlling most experimental factors, the impact of bone samples still remains one of the main causes of temperature variability.

  17. The role of tortuosity on ion conduction in block copolymer electrolyte thin films

    NASA Astrophysics Data System (ADS)

    Kambe, Yu; Arges, Christopher G.; Nealey, Paul F.

    This talk discusses the role of grain tortuosity on ion conductivity in block copolymer electrolyte (BCE) thin films. In particular, we studied lamellae forming BCEs with both domains oriented perpendicular to the substrate surface and connected directly from one electrode to another - i.e., tortuosity of one. The BCE is composed of ion-conducting, poly(2-vinyl n-methylpyridinium) blocks and non-ionic polystyrene blocks. Prior to creating the BCE, the pristine block copolymer, poly(styrene- b-2-vinyl pyridine), was directly self-assembled (DSA) on topographical or chemical patterns via graphoepitaxy and chemoepitaxy. A chemical vapor infiltration reaction modified the P2VP block into positively charged, fixed quaternary ammonium groups paired with mobile counteranions. The graphoepitaxy process utilized topographical interdigitated gold nanoelectrodes (100s of nanometers spacing between electrodes) created via e-beam lithography. Alternatively, chemical patterns had gold electrodes incorporated into them with 10s to 100s of microns spacing using conventional optical lithography. The interdigitated gold electrodes enabled in-plane ion conductivity measurements of the DSA BCEs to study the role of grain tortuosity on ion conductivity. U.S. Department of Energy Office of Science: Contract No. DE-AC02-06CH11357.

  18. Polymer-based platform for microfluidic systems

    DOEpatents

    Benett, William [Livermore, CA; Krulevitch, Peter [Pleasanton, CA; Maghribi, Mariam [Livermore, CA; Hamilton, Julie [Tracy, CA; Rose, Klint [Boston, MA; Wang, Amy W [Oakland, CA

    2009-10-13

    A method of forming a polymer-based microfluidic system platform using network building blocks selected from a set of interconnectable network building blocks, such as wire, pins, blocks, and interconnects. The selected building blocks are interconnectably assembled and fixedly positioned in precise positions in a mold cavity of a mold frame to construct a three-dimensional model construction of a microfluidic flow path network preferably having meso-scale dimensions. A hardenable liquid, such as poly (dimethylsiloxane) is then introduced into the mold cavity and hardened to form a platform structure as well as to mold the microfluidic flow path network having channels, reservoirs and ports. Pre-fabricated elbows, T's and other joints are used to interconnect various building block elements together. After hardening the liquid the building blocks are removed from the platform structure to make available the channels, cavities and ports within the platform structure. Microdevices may be embedded within the cast polymer-based platform, or bonded to the platform structure subsequent to molding, to create an integrated microfluidic system. In this manner, the new microfluidic platform is versatile and capable of quickly generating prototype systems, and could easily be adapted to a manufacturing setting.

  19. Liquid-based cytology and cell block immunocytochemistry in veterinary medicine: comparison with standard cytology for the evaluation of canine lymphoid samples.

    PubMed

    Fernandes, N C C A; Guerra, J M; Réssio, R A; Wasques, D G; Etlinger-Colonelli, D; Lorente, S; Nogueira, E; Dagli, M L Z

    2016-08-01

    Liquid-based Cytology (LBC) consists of immediate wet cell fixation with automated slide preparation. We applied LBC, cell block (CB) and immunocytochemistry to diagnose canine lymphoma and compare results with conventional cytology. Samples from enlarged lymph nodes of 18 dogs were collected and fixed in preservative solution for automated slide preparation (LBC), CB inclusion and immunophenotyping. Two CB techniques were tested: fixed sediment method (FSM) and agar method (AM). Anti-CD79a, anti-Pax5, anti-CD3 and anti-Ki67 were used in immunocytochemistry. LBC smears showed better nuclear and nucleolar definition, without cell superposition, but presented smaller cell size and worse cytoplasmic definition. FSM showed consistent cellular groups and were employed for immunocytochemistry, while AM CBs presented sparse groups of lymphocytes, with compromised analysis. Anti-Pax-5 allowed B-cell identification, both in reactive and neoplastic lymph nodes. Our preliminary report suggests that LBC and FSM together may be promising tools to improve lymphoma diagnosis through fine-needle aspiration. © 2015 John Wiley & Sons Ltd.

  20. Evaluation of formalin-fixed paraffin-embedded tissues obtained from vaccine site-associated sarcomas of cats for DNA of feline immunodeficiency virus.

    PubMed

    Kidney, B A; Ellis, J A; Haines, D M; Jackson, M L

    2000-09-01

    To evaluate the use of a polymerase chain reaction (PCR) method for detection of feline immunodeficiency virus (FIV) DNA, using formalin-fixed paraffin-embedded (FFPE) tissues, and to use this method to evaluate tissues obtained from vaccine site-associated sarcomas (VSS) of cats for FIV DNA. 50 FFPE tissue blocks from VSS of cats and 50 FFPE tissue blocks from cutaneous non-vaccine site-associated fibrosarcomas (non-VSS) of cats. DNA was extracted from FFPE sections of each tumor and regions of the gag gene of FIV were amplified by a PCR, using 3 sets of primers. Sensitivity of the method was compared between frozen and FFPE tissues, using splenic tissue obtained from a cat that had been experimentally infected with FIV. We did not detect FIV DNA in VSS or non-VSS tissues. Sensitivity of the PCR method was identical for frozen or FFPE tissues. It is possible to detect FIV DNA in FFPE tissues by use of a PCR. We did not find evidence to support direct FIV involvement in the pathogenesis of VSS in cats.

  1. Choice in situations of time-based diminishing returns: immediate versus delayed consequences of action.

    PubMed Central

    Hackenberg, T D; Hineline, P N

    1992-01-01

    Pigeons chose between two schedules of food presentation, a fixed-interval schedule and a progressive-interval schedule that began at 0 s and increased by 20 s with each food delivery provided by that schedule. Choosing one schedule disabled the alternate schedule and stimuli until the requirements of the chosen schedule were satisfied, at which point both schedules were again made available. Fixed-interval duration remained constant within individual sessions but varied across conditions. Under reset conditions, completing the fixed-interval schedule not only produced food but also reset the progressive interval to its minimum. Blocks of sessions under the reset procedure were interspersed with sessions under a no-reset procedure, in which the progressive schedule value increased independent of fixed-interval choices. Median points of switching from the progressive to the fixed schedule varied systematically with fixed-interval value, and were consistently lower during reset than during no-reset conditions. Under the latter, each subject's choices of the progressive-interval schedule persisted beyond the point at which its requirements equaled those of the fixed-interval schedule at all but the highest fixed-interval value. Under the reset procedure, switching occurred at or prior to that equality point. These results qualitatively confirm molar analyses of schedule preference and some versions of optimality theory, but they are more adequately characterized by a model of schedule preference based on the cumulated values of multiple reinforcers, weighted in inverse proportion to the delay between the choice and each successive reinforcer. PMID:1548449

  2. Did I see your hand moving? The effect of movement-related information on the Corsi block tapping task.

    PubMed

    Brunetti, Riccardo; Del Gatto, Claudia; Cavallina, Clarissa; Farina, Benedetto; Delogu, Franco

    2018-05-01

    The Corsi Block Tapping Task is a widespread test used to assess spatial working memory. Previous research hypothesized that the discrepancy found in some cases between the traditional and the digital (touchscreen) version of the Corsi block tapping task may be due to a direct motor resonance between the experimenter's and the participant's hand movements. However, we hypothesize that this discrepancy might be due to extra movement-related information included in the traditional version, lacking in the digital one. We investigated the effects of such task-irrelevant information using eCorsi, a touchscreen version of the task. In Experiment 1, we manipulate timing in sequence presentation, creating three conditions. In the Congruent condition, the inter-stimulus intervals reflected the physical distance in which the stimuli were spatially placed: The longer the spatial distance, the longer the temporal interval. In the Incongruent condition the timing changed randomly. Finally, in the Isochronous condition every stimulus appeared after a fixed interval, independently from its spatial position. The results showed a performance enhancement in the Congruent condition, suggesting an incidental spatio-temporal binding. In Experiment 2, we added straight lines between each location in the sequences: In the Trajectories condition participants saw trajectories from one spatial position to the other during sequence presentation, while a condition without such trajectories served as control. Results showed better performances in the Trajectories condition. We suggest that the timing and trajectories information play a significant role in the discrepancies found between the traditional and the touchscreen version of the Corsi Block Tapping Task, without the necessity of explanations involving direct motor resonance (e.g. seeing an actual hand moving) as a causal factor.

  3. Validation of the Complexity INdex in SARComas prognostic signature on formalin-fixed, paraffin-embedded, soft tissue sarcomas.

    PubMed

    Le Guellec, S; Lesluyes, T; Sarot, E; Valle, C; Filleron, T; Rochaix, P; Valentin, T; Pérot, G; Coindre, J-M; Chibon, F

    2018-05-31

    Prediction of metastatic outcome in sarcomas is challenging for clinical management since they are aggressive and carry a high metastatic risk. A 67-gene expression signature, the Complexity INdex in SARComas (CINSARC), has been identified as a better prognostic factor than the reference pathological grade. Since it cannot be applied easily in standard laboratory practice, we assessed its prognostic value using nanoString on formalin-fixed, paraffin-embedded (FFPE) blocks to evaluate its potential in clinical routine practice and guided therapeutic management. A code set consisting of 67 probes derived from the 67 genes of the CINSARC signature was built and named NanoCind®. To compare the performance of RNA-seq and nanoString (NanoCind®), we used expressions of various sarcomas (n=124, frozen samples) using both techniques and compared predictive values based on CINSARC risk groups and clinical annotations. We also used nanoString on FFPE blocks (n=67) and matching frozen and FFPE samples (n=45) to compare their level of agreement. Metastasis-free survival and agreement values in classification groups were evaluated. CINSARC strongly predicted metastatic outcome using nanoString on frozen samples (HR = 2.9, 95% CI 1.23-6.82) with similar risk-group classifications (86%). While more than 50% of FFPE blocks were not analyzable by RNA-seq owing to poor RNA quality, all samples were analyzable with nanoString. When similar (risk-group) classifications were measured with frozen tumors (RNA-seq) compared to FFPE blocks (84% agreement), the CINSARC signature was still a predictive factor of metastatic outcome with nanoString on FFPE samples (HR = 4.43, 95% CI 1.25-15.72). CINSARC is a material-independent prognostic signature for metastatic outcome in sarcomas and outperforms histological grade. Unlike RNA-seq, nanoString is not influenced by the poor quality of RNA extracted from FFPE blocks. The CINSARC signature can potentially be used in combination with nanoString (NanoCind®) in routine clinical practice on FFPE blocks to predict metastatic outcome.

  4. Exact partition functions for deformed N=2 theories with N_f=4 flavours

    NASA Astrophysics Data System (ADS)

    Beccaria, Matteo; Fachechi, Alberto; Macorini, Guido; Martina, Luigi

    2016-12-01

    We consider the Ω-deformed N=2 SU(2) gauge theory in four dimensions with N f = 4 massive fundamental hypermultiplets. The low energy effective action depends on the deformation parameters ɛ 1 , ɛ 2, the scalar field expectation value a, and the hypermultiplet masses m = ( m 1 , m 2 , m 3 , m 4). Motivated by recent findings in the N={2}^{*} theory, we explore the theories that are characterized by special fixed ratios ɛ 2 /ɛ 1 and m /ɛ 1 and propose a simple condition on the structure of the multi-instanton contributions to the prepotential determining the effective action. This condition determines a finite set Π N of special points such that the prepotential has N poles at fixed positions independent on the instanton number. In analogy with what happens in the N={2}^{*} gauge theory, the full prepotential of the Π N theories may be given in closed form as an explicit function of a and the modular parameter q appearing in special combinations of Eisenstein series and Jacobi theta functions with well defined modular properties. The resulting finite pole partition functions are related by AGT correspondence to special 4-point spherical conformal blocks of the Virasoro algebra. We examine in full details special cases where the closed expression of the block is known and confirms our Ansatz. We systematically study the special features of Zamolodchikov's recursion for the Π N conformal blocks. As a result, we provide a novel effective recursion relation that can be exactly solved and allows to prove the conjectured closed expressions analytically in the case of the Π1 and Π2 conformal blocks.

  5. Reversible online control of habitual behavior by optogenetic perturbation of medial prefrontal cortex

    PubMed Central

    Smith, Kyle S.; Virkud, Arti; Deisseroth, Karl; Graybiel, Ann M.

    2012-01-01

    Habits tend to form slowly but, once formed, can have great stability. We probed these temporal characteristics of habitual behaviors by intervening optogenetically in forebrain habit circuits as rats performed well-ingrained habitual runs in a T-maze. We trained rats to perform a maze habit, confirmed the habitual behavior by devaluation tests, and then, during the maze runs (ca. 3 s), we disrupted population activity in a small region in the medial prefrontal cortex, the infralimbic cortex. In accordance with evidence that this region is necessary for the expression of habits, we found that this cortical disruption blocked habitual behavior. Notably, however, this blockade of habitual performance occurred on line, within an average of three trials (ca. 9 s of inhibition), and as soon as during the first trial (<3 s). During subsequent weeks of training, the rats acquired a new behavioral pattern. When we again imposed the same cortical perturbation, the rats regained the suppressed maze-running that typified the original habit, and, simultaneously, the more recently acquired habit was blocked. These online changes occurred within an average of two trials (ca. 6 s of infralimbic inhibition). Measured changes in generalized performance ability and motivation to consume reward were unaffected. This immediate toggling between breaking old habits and returning to them demonstrates that even semiautomatic behaviors are under cortical control and that this control occurs online, second by second. These temporal characteristics define a framework for uncovering cellular transitions between fixed and flexible behaviors, and corresponding disturbances in pathologies. PMID:23112197

  6. Passive forensics for copy-move image forgery using a method based on DCT and SVD.

    PubMed

    Zhao, Jie; Guo, Jichang

    2013-12-10

    As powerful image editing tools are widely used, the demand for identifying the authenticity of an image is much increased. Copy-move forgery is one of the tampering techniques which are frequently used. Most existing techniques to expose this forgery need to improve the robustness for common post-processing operations and fail to precisely locate the tampering region especially when there are large similar or flat regions in the image. In this paper, a robust method based on DCT and SVD is proposed to detect this specific artifact. Firstly, the suspicious image is divided into fixed-size overlapping blocks and 2D-DCT is applied to each block, then the DCT coefficients are quantized by a quantization matrix to obtain a more robust representation of each block. Secondly, each quantized block is divided non-overlapping sub-blocks and SVD is applied to each sub-block, then features are extracted to reduce the dimension of each block using its largest singular value. Finally, the feature vectors are lexicographically sorted, and duplicated image blocks will be matched by predefined shift frequency threshold. Experiment results demonstrate that our proposed method can effectively detect multiple copy-move forgery and precisely locate the duplicated regions, even when an image was distorted by Gaussian blurring, AWGN, JPEG compression and their mixed operations. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  7. Three-dimensional velocity structure of Siletzia and other accreted terranes in the Cascadia forearc of Washington

    USGS Publications Warehouse

    Parsons, T.; Wells, R.E.; Fisher, M.A.; Flueh, E.; ten Brink, Uri S.

    1999-01-01

    Eocene mafic crust with high seismic velocities underlies much of the Oregon and Washington forearc and acts as a backstop for accretion of marine sedimentary rocks from the obliquely subducting Juan de Fuca slab. Arc-parallel migration of relatively strong blocks of this terrane, known as Siletzia, focuses upper crustal deformation along block boundaries, which are potential sources of earthquakes. In a three-dimensional velocity model of coastal Washington, we have combined surface geology, well data, and travel times from earthquakes and controlled source seismic experiments to resolve the major boundaries of the Siletz terrane with the adjacent accreted sedimentary prism and volcanic arc. In southern Washington and northern Oregon the Siletz terrane appears to be a thick block (???20 km) that extends west of the coastline and makes a high-angle contact with the offshore accreted sedimentary prism. On its east flank the high-velocity Siletz terrane boundary coincides with an en echelon zone of seismicity in the arc. In northern Washington the western edge of Siletzia makes a lower-angled, fault-bound contact with the accretionary prism. In addition, alternating, east-west trending uplifts and downwarps of the Siletz terrane centered on the antiformal Olympic Mountains may reflect focusing of north-south compression in the northern part of the Siletz terrane. This compressional strain may result from northward transport and clockwise rotation of the Siletz terrane into the relatively fixed Canadian Coast Mountains restraining bend along the coast.

  8. Design and installation of a next generation pilot scale fermentation system.

    PubMed

    Junker, B; Brix, T; Lester, M; Kardos, P; Adamca, J; Lynch, J; Schmitt, J; Salmon, P

    2003-01-01

    Four new fermenters were designed and constructed for use in secondary metabolite cultivations, bioconversions, and enzyme production. A new PC/PLC-based control system also was implemented using GE Fanuc PLCs, Genius I/O blocks, and Fix Dynamics SCADA software. These systems were incorporated into an industrial research fermentation pilot plant, designed and constructed in the early 1980s. Details of the design of these new fermenters and the new control system are described and compared with the existing installation for expected effectiveness. In addition, the reasoning behind selection of some of these features has been included. Key to the design was the goal of preserving similarity between the new and previously existing and successfully utilized fermenter hardware and software installations where feasible but implementing improvements where warranted and beneficial. Examples of enhancements include strategic use of Inconel as a material of construction to reduce corrosion, piping layout design for simplified hazardous energy isolation, on-line calculation and control of nutrient feed rates, and the use of field I/O modules located near the vessel to permit low-cost addition of new instrumentation.

  9. The anatomic basis of lingual nerve trauma associated with inferior alveolar block injections.

    PubMed

    Morris, Christopher D; Rasmussen, Jared; Throckmorton, Gaylord S; Finn, Richard

    2010-11-01

    This study describes the anatomic variability in the position of the lingual nerve in the pterygomandibular space, the location of the inferior alveolar nerve block injection. Simulated standard landmark-based inferior alveolar nerve blocks were administered to 44 fixed sagitally bisected cadaver heads. Measurements were made of the diameter of the nerves and distances between the needle and selected anatomic landmarks and the nerves. Of 44 simulated injections, 42 (95.5%) passed lateral to the lingual nerve, 7 (16%) passed within 0.1 mm of the nerve, and 2 (4.5%) penetrated the nerve. The position of the lingual nerve relative to bony landmarks within the interpterygoid fascia was highly variable. Variation in the position of the lingual nerve is an important contributor to lingual nerve trauma during inferior alveolar block injections. This factor should be an important part of preoperative informed consent. Copyright © 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Resonant soft x-ray GISAXS on block copolymer films

    NASA Astrophysics Data System (ADS)

    Wang, Cheng; Araki, T.; Watts, B.; Ade, H.; Hexemer, A.; Park, S.; Russell, T. P.; Schlotter, W. F.; Stein, G. E.; Tang, C.; Kramer, E. J.

    2008-03-01

    Ordered block copolymer thin films may have important applications in modern device fabrication. Current characterization methods such as conventional GISAXS have fixed electron density contrast that can be overwhelmed by surface scattering. However, soft x-rays have longer wavelength, energy dependent contrast and tunable penetration, making resonant GISAXS a very promising tool for probing nanostructured polymer thin films. Our preliminary investigation was performed using PS-b-P2VP block copolymer films on beam-line 5-2 SSRL, and beam-line 6.3.2 at ALS, LBNL. The contrast/sensitivity of the scattering pattern varies significantly with photon energy close to the C K-edge (˜290 eV). Also, higher order peaks are readily observed, indicating hexagonal packing structure in the sample. Comparing to the hard x-ray GISAXS data of the same system, it is clear that resonant GISAXS has richer data and better resolution. Beyond the results on the A-B diblock copolymers, results on ABC block copolymers are especially interesting.

  11. Effects of narasin (Skycis) on live performance and carcass traits of finishing pigs sold in a three-phase marketing system.

    PubMed

    Arkfeld, E K; Carr, S N; Rincker, P J; Gruber, S L; Allee, G L; Dilger, A C; Boler, D D

    2015-10-01

    The objective was to evaluate the effect of feeding narasin (Skycis; Elanco Animal Health, Greenfield, IN) on growth performance and carcass characteristics of finishing pigs sold in a 3-phase marketing system. Pigs ( = 1,232) were housed in 56 single-sex pens (22 pigs/pen) divided into 2 even blocks based on initiation of treatment. Each treatment × sex combination was replicated 14 times. Pigs were fed either 0 mg/kg narasin (control) or 15 mg/kg narasin for up to 85 d of finishing (initiated at an average of 52.95 kg BW). In each pen, 18% (4 pigs per pen) of pigs were sold in the first marketing group (Day 64 of dietary treatment), 50% (11 of the original 22) were sold in the second marketing group (Day 78), and 32% (the remaining 7 pigs) were sold in the third marketing group (Day 85). Data were analyzed as a randomized complete block design with pen as the experimental unit. The model included the fixed effects of diet, sex, and their interaction. Block and replicate nested within block were random variables. Carcass data from pigs in marketing group 3 of block 2 was not collected due to inclement weather. Narasin had no effect on growth performance traits ( ≥ 0.15) in phases 1 (Days 1-28) or 2 (Days 29-56), regardless of sex. Barrows fed narasin had a 2.0% greater overall (Day 0-85) ADG than barrows fed the control diet ( < 0.01), but ADG of gilts was not different due to diet ( = 0.69). Regardless of sex, narasin improved ( = 0.03) feed efficiency (G:F) by 1.3% throughout the 85-d feeding period. There were no effects ( ≥ 0.21) of narasin on carcass composition in marketing groups 1 and 2. Narasin-fed barrows in marketing group 3 had 0.9 percentage units lower ( < 0.01) estimated carcass lean compared with barrows fed control diets (51.0 vs. 52.0%); no difference existed in gilts ( = 0.21). This is likely due to narasin-fed barrows of marketing group 3 tending ( = 0.06) to have 7.7% greater fat depth than control barrows of marketing group 3. Pooled effects (across all 3 marketing groups) of feeding narasin tended ( = 0.08) to reduce loin depth by 1.1% (60.00 vs. 60.66 mm), but there were no effects on fat depth ( = 0.24) or estimated carcass lean ( = 0.11). Overall, narasin can be used during the last 85 d of feeding to increase feed efficiency of barrows and gilts with minimal impact on carcass composition.

  12. Fluid-structure interaction in straight pipelines with different anchoring conditions

    NASA Astrophysics Data System (ADS)

    Ferras, David; Manso, Pedro A.; Schleiss, Anton J.; Covas, Dídia I. C.

    2017-04-01

    This investigation aims at assessing the fluid-structure interaction (FSI) occurring during hydraulic transients in straight pipeline systems fixed to anchor blocks. A two mode 4-equation model is implemented incorporating the main interacting mechanisms: Poisson, friction and junction coupling. The resistance to movement due to inertia and dry friction of the anchor blocks is treated as junction coupling. Unsteady skin friction is taken into account in friction coupling. Experimental waterhammer tests collected from a straight copper pipe-rig are used for model validation in terms of wave shape, timing and damping. Numerical results successfully reproduce laboratory measurements for realistic values of calibration parameters. The novelty of this paper is the presentation of a 1D FSI solver capable of describing the resistance to movement of anchor blocks and its effect on the transient pressure wave propagation in straight pipelines.

  13. Multibracket appliance: impression defaults and their reduction by blocking-out  -  a three-dimensional study.

    PubMed

    Wriedt, Susanne; Foersch, Moritz; Muhle, Jan Daniel; Schmidtmann, Irene; Wehrbein, Heinrich

    2016-03-01

    This study examines accuracy of dental impressions and following plaster models taken during treatment with fixed appliances. A maxillary typodont was provided with brackets. Three examiners took impressions three times each of the variants: brackets only, archwire fixed by alastics, ligatures or Kobayashi-hooks, and brackets and archwire covered completely or just on the gingival side by protection or impression wax. Casts were scanned using Activity102(®). Virtual models were compared to the scan of the typodont using Comparison(®). Differences were measured and descriptively analyzed. Estimated means with 95% confidence intervals were computed. Significance was assessed using linear mixed models. While pyramidal reference blocks had a mean difference of 0.019 mm (95% CI = 0.017-0.021 mm) to the master model, teeth without attachments showed 0.097 mm (95% CI = 0.082-0.111 mm), and teeth with brackets 0.169 mm (95% CI = 0.156-0.182 mm) (p < 0.001). Smallest mean was found when using protection wax only on the gingival bracket side (0.152 mm (95% CI = 0.113-0.192 mm)). Incisors deviated most (0.258 mm (95 % CI = 0.239-0.277 mm)). Teeth with brackets make impressions more inaccurate because of undercuts. Removing the archwire before taking the impression or covering the brackets on the gingival side shows tendencies toward better precision. Taking impressions during treatment with fixed appliances, some inaccuracy has to be taken into account.

  14. Blocking effect of rheumatoid factor and cold agglutinins on complement fixation tests for histoplasmosis.

    PubMed Central

    Johnson, J E; Roberts, G D

    1976-01-01

    The blocking effect of rheumatoid factor (RF) and cold agglutinins (CA) on the detection of complement-fixing (CF) antibodies for Histoplasma capsulatum using a mycelial (histoplasmin) and a yeast antigen was studied. Sera from 213 patients serologically positive for histoplasmosis were screened for the presence of RF or CA. CF antibodies to H. capsulatum in sera containing RF or CA were studied before and after removal of these factors (RF and CA) by treatment with dithiothreitol. Results suggest that RF or CA may interfere with the CF reaction to the yeast antigen of H. capsulatum but not to the mycelial antigen (histoplasmin). PMID:1254713

  15. An Imide-Based Pentacyclic Building Block for n-Type Organic Semiconductors

    DOE PAGES

    Wu, Fu-Peng; Un, Hio-Ieng; Li, Yongxi; ...

    2017-10-09

    For this study a new electron-deficient unit with fused 5-heterocyclic ring was developed by replacing a cyclopenta-1,3-diene from electron-rich donor indacenodithiophene (IDT) with cyclohepta-4,6-diene-1,3-diimde unit. The imide bridging endows BBI with fixed planar configuration and both low the highest occupied molecular orbital (HOMO) (-6.24 eV) and the lowest unoccupied molecular orbit (LUMO) (-2.57 eV) energy levels. Organic field-effect transistors (OFETs) based on BBI polymers exhibit electron mobility up to 0.34 cm 2 V -1 s -1, which indicates that the BBI is a promising n-type building block for optoelectronics.

  16. Theoretical lower bounds for parallel pipelined shift-and-add constant multiplications with n-input arithmetic operators

    NASA Astrophysics Data System (ADS)

    Cruz Jiménez, Miriam Guadalupe; Meyer Baese, Uwe; Jovanovic Dolecek, Gordana

    2017-12-01

    New theoretical lower bounds for the number of operators needed in fixed-point constant multiplication blocks are presented. The multipliers are constructed with the shift-and-add approach, where every arithmetic operation is pipelined, and with the generalization that n-input pipelined additions/subtractions are allowed, along with pure pipelining registers. These lower bounds, tighter than the state-of-the-art theoretical limits, are particularly useful in early design stages for a quick assessment in the hardware utilization of low-cost constant multiplication blocks implemented in the newest families of field programmable gate array (FPGA) integrated circuits.

  17. An Imide-Based Pentacyclic Building Block for n-Type Organic Semiconductors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Fu-Peng; Un, Hio-Ieng; Li, Yongxi

    For this study a new electron-deficient unit with fused 5-heterocyclic ring was developed by replacing a cyclopenta-1,3-diene from electron-rich donor indacenodithiophene (IDT) with cyclohepta-4,6-diene-1,3-diimde unit. The imide bridging endows BBI with fixed planar configuration and both low the highest occupied molecular orbital (HOMO) (-6.24 eV) and the lowest unoccupied molecular orbit (LUMO) (-2.57 eV) energy levels. Organic field-effect transistors (OFETs) based on BBI polymers exhibit electron mobility up to 0.34 cm 2 V -1 s -1, which indicates that the BBI is a promising n-type building block for optoelectronics.

  18. Multistage Computerized Adaptive Testing with Uniform Item Exposure

    ERIC Educational Resources Information Center

    Edwards, Michael C.; Flora, David B.; Thissen, David

    2012-01-01

    This article describes a computerized adaptive test (CAT) based on the uniform item exposure multi-form structure (uMFS). The uMFS is a specialization of the multi-form structure (MFS) idea described by Armstrong, Jones, Berliner, and Pashley (1998). In an MFS CAT, the examinee first responds to a small fixed block of items. The items comprising…

  19. 48 CFR 215.404-71-3 - Contract type risk and working capital adjustment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... varying contract types. The working capital adjustment is an adjustment added to the profit objective for... Base (item 20) Profit objective 24. CONTRACT type risk (1) (2) (3) Cost financed Length factor Interest... money. (3) Multiply (1) by (2). (4) Only complete this block when the prospective contract is a fixed...

  20. 48 CFR 215.404-71-3 - Contract type risk and working capital adjustment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... varying contract types. The working capital adjustment is an adjustment added to the profit objective for... Base (item 20) Profit objective 24. CONTRACT type risk (1) (2) (3) Cost financed Length factor Interest... money. (3) Multiply (1) by (2). (4) Only complete this block when the prospective contract is a fixed...

  1. 48 CFR 215.404-71-3 - Contract type risk and working capital adjustment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... varying contract types. The working capital adjustment is an adjustment added to the profit objective for... Base (item 20) Profit objective 24. CONTRACT type risk (1) (2) (3) Cost financed Length factor Interest... money. (3) Multiply (1) by (2). (4) Only complete this block when the prospective contract is a fixed...

  2. Development and Application of Detection Indices for Measuring Guessing Behaviors and Test-Taking Effort in Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Chang, Shu-Ren; Plake, Barbara S.; Kramer, Gene A.; Lien, Shu-Mei

    2011-01-01

    This study examined the amount of time that different ability-level examinees spend on questions they answer correctly or incorrectly across different pretest item blocks presented on a fixed-length, time-restricted computerized adaptive testing (CAT). Results indicate that different ability-level examinees require different amounts of time to…

  3. 49 CFR 231.2 - Hopper cars and high-side gondolas with fixed ends.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... which time they must be made to comply with the standards prescribed. (iv) Carriers are not required to... within 12 inches of a vertical plane parallel with end of car and passing through the inside face of... outer face of buffer block. (2) Carriers are not required to make changes to secure additional end...

  4. 47 CFR 27.1021 - Reimbursement obligation of licensees at 1915-1920 MHz.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... the first auction (calculated under paragraphs (a) or (b), as applicable, of this section). (d) For... licensees at 1915-1920 MHz. A licensee in the 1915-1920 MHz band (Lower H Block) shall, within 30 days of..., Inc. for relocating and clearing incumbent Fixed Microwave Service (FS) licensees from the 1910-1930...

  5. 47 CFR 27.1021 - Reimbursement obligation of licensees at 1915-1920 MHz.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... the first auction (calculated under paragraphs (a) or (b), as applicable, of this section). (d) For... licensees at 1915-1920 MHz. A licensee in the 1915-1920 MHz band (Lower H Block) shall, within 30 days of..., Inc. for relocating and clearing incumbent Fixed Microwave Service (FS) licensees from the 1910-1930...

  6. Skylab program CSM verification analysis report

    NASA Technical Reports Server (NTRS)

    Schaefer, J. L.; Vanderpol, G. A.

    1970-01-01

    The application of the SINDA computer program for the transient thermodynamic simulation of the Apollo fuel cell/radiator system for the limit condition of the proposed Skylab mission is described. Results are included for the thermal constraints imposed upon the Pratt and Whitney fuel cell power capability by the Block 2 EPS radiator system operating under the Skylab fixed attitude orbits.

  7. Fixed-interval performance and self-control in children.

    PubMed Central

    Darcheville, J C; Rivière, V; Wearden, J H

    1992-01-01

    Operant responses of 16 children (mean age 6 years and 1 month) were reinforced according to different fixed-interval schedules (with interreinforcer intervals of 20, 30, or 40 s) in which the reinforcers were either 20-s or 40-s presentations of a cartoon. In another procedure, they received training on a self-control paradigm in which both reinforcer delay (0.5 s or 40 s) and reinforcer duration (20 s or 40 s of cartoons) varied, and subjects were offered a choice between various combinations of delay and duration. Individual differences in behavior under the self-control procedure were precisely mirrored by individual differences under the fixed-interval schedule. Children who chose the smaller immediate reinforcer on the self-control procedure (impulsive) produced short postreinforcement pauses and high response rates in the fixed-interval conditions, and both measures changed little with changes in fixed-interval value. Conversely, children who chose the larger delayed reinforcer in the self-control condition (the self-controlled subjects) exhibited lower response rates and long postreinforcement pauses, which changed systematically with changes in the interval, in their fixed-interval performances. PMID:1573372

  8. Coordinated train control and energy management control strategies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gordon, S.P.; Lehrer, D.G.

    1998-05-01

    The Bay Area Rapid Transit (BART) system, in collaboration with Hughes Aircraft Company and Harmon Industries, as in the process of developing an Advanced Automatic Train Control (AATC) system to replace the current fixed-block automatic system. In the long run, the AATC system is expected to not only allow for safe short headway operation, but also to facilitate coordinated train control and energy management. This new system will employ spread spectrum radios, installed onboard trains, at wayside locations, and at control stations, to determine train locations and reliably transfer control information. Sandia National Laboratories has worked cooperatively with BART tomore » develop a simulator of the train control and the power consumption of the AATC system. The authors are now in the process of developing enhanced train control algorithms to supplement the safety critical controller in order to smooth out train trajectories through coordinated control of multiple trains, and to reduce energy consumption and power infrastructure requirements. The control algorithms so far considered include (1) reducing peak power consumption to avoid voltage sags, especially during an outage or while clearing a backup, (2) rapid and smooth recovery from a backup, (3) avoiding oscillations due to train interference, (4) limiting needle peaks in power demand at substations to some specified level, (5) coasting, and (6) coordinating train movement, e.g., starts/stops and hills.« less

  9. Young Investigator Challenge: A novel, simple method for cell block preparation, implementation, and use over 2 years.

    PubMed

    Lindsey, Kathryn G; Houser, Patricia M; Shotsberger-Gray, Wanda; Chajewski, Olga S; Yang, Jack

    2016-12-01

    The cell block is an essential adjunct to conventional cytopreparatory techniques. The need for molecular analysis and immunostains will increase the need for successful cell block preparation. Even with this need, to the authors' knowledge very little has changed regarding the way in which cell blocks are produced. The authors developed A Formalin-Fixed, paraffin Embedded Cytology cell block Technique (AFFECT) that uses a cytospin centrifuge and funnel to deposit a cell pellet into a well on a piece of open-cell, absorbent foam. The foam and the pellet are then sent through normal processing. Herein, the authors present the implementation of this method and some of their experience with its performance over the course of 2 years. Although a comparison of the methods indicated good correlation for the production of a cell block between AFFECT and the agarose method, the AFFECT blocks demonstrated markedly improved cellular morphology. Over the first 6 months of use, AFFECT produced a successful cell block in 74% of cases overall, and in 65% of cases with a cell pellet measuring ≤0.1 mL. The year preceding the implementation of AFFECT and its first year of use were compared for endoscopic and bronchoscopic ultrasound-guided fine-needle aspiration specimens, and demonstrated an improved success rate. The authors developed a novel method of cell block preparation that demonstrates improved histology and has increased the success rate of cell block production compared with the agarose method. Cancer Cytopathol 2016;124:885-892. © 2016 American Cancer Society. © 2016 American Cancer Society.

  10. Photogrammetric analysis of horizon panoramas: The Pathfinder landing site in Viking orbiter images

    USGS Publications Warehouse

    Oberst, J.; Jaumann, R.; Zeitler, W.; Hauber, E.; Kuschel, M.; Parker, T.; Golombek, M.; Malin, M.; Soderblom, L.

    1999-01-01

    Tiepoint measurements, block adjustment techniques, and sunrise/sunset pictures were used to obtain precise pointing data with respect to north for a set of 33 IMP horizon images. Azimuth angles for five prominent topographic features seen at the horizon were measured and correlated with locations of these features in Viking orbiter images. Based on this analysis, the Pathfinder line/sample coordinates in two raw Viking images were determined with approximate errors of 1 pixel, or 40 m. Identification of the Pathfinder location in orbit imagery yields geological context for surface studies of the landing site. Furthermore, the precise determination of coordinates in images together with the known planet-fixed coordinates of the lander make the Pathfinder landing site the most important anchor point in current control point networks of Mars. Copyright 1999 by the American Geophysical Union.

  11. The Prevalence of Human Papilloma Virus in Esophageal Squamous Cell Carcinoma

    PubMed Central

    Noori, Sadat; Monabati, Ahmad; Ghaderi, Abbasali

    2012-01-01

    Background: Carcinomas of esophagus, mostly squamous cell carcinomas, occur throughout the world. There are a number of suspected genetic or environmental etiologies. Human papilloma virus (HPV) is said to be a major etiology in areas with high incidence of esophageal carcinoma, while it is hardly detectable in low incidence regions. This study was designed to evaluate the prevalence of HPV in esophageal squamous cell carcinoma (ESCC) cases diagnosed in Pathology Department, Medical School, Shiraz University of Medical Sciences. Methods: DNA material for PCR amplification of HPV genome was extracted from formalin-fixed paraffin-embedded tissue blocks of 92 cases of ESCC, diagnosed during 20 years from 1982 to 2002. Polymerase chain reaction was performed for amplification and detection of common HPV and type specific HPV-16 and HPV-18 genomic sequences in the presence of positive control (HPV-18 and HPV positive biopsies of uterine exocervix) and additional internal controls i.e. beta-globin and cytotoxic T lymphocyte antigen 4 (CTLA4). Result: Good amplification of positive control and internal controls was observed. However, no amplification of HPV genome was observed. Conclusion: There is no association between HPV infection and the development of esophageal squamous cell carcinoma in the cases evaluated. PMID:23115442

  12. Active field control (AFC) -electro-acoustic enhancement system using acoustical feedback control

    NASA Astrophysics Data System (ADS)

    Miyazaki, Hideo; Watanabe, Takayuki; Kishinaga, Shinji; Kawakami, Fukushi

    2003-10-01

    AFC is an electro-acoustic enhancement system using FIR filters to optimize auditory impressions, such as liveness, loudness, and spaciousness. This system has been under development at Yamaha Corporation for more than 15 years and has been installed in approximately 50 venues in Japan to date. AFC utilizes feedback control techniques for recreation of reverberation from the physical reverberation of the room. In order to prevent coloration problems caused by a closed loop condition, two types of time-varying control techniques are implemented in the AFC system to ensure smooth loop gain and a sufficient margin in frequency characteristics to prevent instability. Those are: (a) EMR (electric microphone rotator) -smoothing frequency responses between microphones and speakers by changing the combinations of inputs and outputs periodically; (b) fluctuating-FIR -smoothing frequency responses of FIR filters and preventing coloration problems caused by fixed FIR filters, by moving each FIR tap periodically on time axis with a different phase and time period. In this paper, these techniques are summarized. A block diagram of AFC using new equipment named AFC1, which has been developed at Yamaha Corporation and released recently in the US, is also presented.

  13. Development and validation of a protocol for optimizing the use of paraffin blocks in molecular epidemiological studies: The example from the HPV-AHEAD study.

    PubMed

    Mena, Marisa; Lloveras, Belen; Tous, Sara; Bogers, Johannes; Maffini, Fausto; Gangane, Nitin; Kumar, Rekha Vijay; Somanathan, Thara; Lucas, Eric; Anantharaman, Devasena; Gheit, Tarik; Castellsagué, Xavier; Pawlita, Michael; de Sanjosé, Silvia; Alemany, Laia; Tommasino, Massimo

    2017-01-01

    Worldwide use of formalin-fixed paraffin-embedded blocks (FFPE) is extensive in diagnosis and research. Yet, there is a lack of optimized/standardized protocols to process the blocks and verify the quality and presence of the targeted tissue. In the context of an international study on head and neck cancer (HNC)-HPV-AHEAD, a standardized protocol for optimizing the use of FFPEs in molecular epidemiology was developed and validated. First, a protocol for sectioning the FFPE was developed to prevent cross-contamination and distributed between participating centers. Before processing blocks, all sectioning centers underwent a quality control to guarantee a satisfactory training process. The first and last sections of the FFPEs were used for histopathological assessment. A consensus histopathology evaluation form was developed by an international panel of pathologists and evaluated for four indicators in a pilot analysis in order to validate it: 1) presence/type of tumor tissue, 2) identification of other tissue components that could affect the molecular diagnosis and 3) quality of the tissue. No HPV DNA was found in sections from empty FFPE generated in any histology laboratories of HPV-AHEAD consortium and all centers passed quality assurance for processing after quality control. The pilot analysis to validate the histopathology form included 355 HNC cases. The form was filled by six pathologists and each case was randomly assigned to two of them. Most samples (86%) were considered satisfactory. Presence of >50% of invasive carcinoma was observed in all sections of 66% of cases. Substantial necrosis (>50%) was present in <2% of samples. The concordance for the indicators targeted to validate the histopathology form was very high (kappa > 0.85) between first and last sections and fair to high between pathologists (kappa/pabak 0.21-0.72). The protocol allowed to correctly process without signs of contamination all FFPE of the study. The histopathology evaluation of the cases assured the presence of the targeted tissue, identified the presence of other tissues that could disturb the molecular diagnosis and allowed the assessment of tissue quality.

  14. Triply redundant integrated navigation and asset visibility system

    DOEpatents

    Smith, Stephen F [Loudon, TN; Moore, James A [Powell, TN

    2011-11-29

    Methods and apparatus are described for a navigation system. A method includes providing a global positioning system fix having a plurality of tracking parameters; providing a theater positioning system fix; monitoring the plurality of tracking parameters for predetermined conditions; and, when the predetermined conditions are met, sending a notifying signal and switching to the theater positioning system fix as a primary fix. An apparatus includes a system controller; a global positioning system receiver coupled to the system controller; a radio frequency locating receiver coupled to the system controller; and an operator interface coupled to the system controller.

  15. Triply redundant integrated navigation and asset visibility system

    DOEpatents

    Smith, Stephen F.; Moore, James A.

    2013-01-22

    Methods and apparatus are described for a navigation system. A method includes providing a global positioning system fix having a plurality of tracking parameters; providing a theater positioning system fix; monitoring the plurality of tracking parameters for predetermined conditions; and, when the predetermined conditions are met, sending a notifying signal and switching to the theater positioning system fix as a primary fix. An apparatus includes a system controller; a global positioning system receiver coupled to the system controller; a radio frequency locating receiver coupled to the system controller; and an operator interface coupled to the system controller.

  16. VEGFR-3 Expression in Oral Lichen Planus

    PubMed

    Zolfaghari Saravi, Zahra; Seyedmajidi, Maryam; Sharbatdaran, Majid; Bijani, Ali; Mozaffari, Fatemeh; Aminishakib, Pouyan

    2017-02-01

    Background and objective: Given the postulated the role of inflammation and possible contribution of lymphangiogenesis in oral lichen planus, this study aimed to assess any associated presence of VEGFR-3. Material and Methods: This cross-sectional study was performed on 52 formalin fixed and paraffin embedded blocks of oral lichen planus (pathological diagnosis based on Modified WHO criteria), comprising 25 of erosive and 27 of reticular type, along with 60 samples of normal mucosa (with minimal inflammation from clinical and histopathological aspects) obtained at crown lengthening surgery. Four micron sections were cut from paraffin blocks and stained with H and E for confirmation of diagnosis and by immunohistochemistry with primary antibodies against VEGFR-3. Negative controls were provided by omission of primary antibody and placenta was considered as a positive control. Data were analyzed by Chi-square, Mann-Whitney and Kruskal-wallis tests and P <0.05 was considered statistically significant. Findings: VEGFR-3 expression was apparent in 61.5% of lichen planus specimens and 5% of those from normal mucosa (p<0.001). Also, the average number of stained vessels was significantly higher in oral lichen planus than in normal mucosa (p<0.001). VEGFR-3 expression in oral lichen planus (p=0.262) and the average number of stained vessels (p=0.092) demonstrated no significant difference according to the type. Conclusion: It appears that VEGFR-3 expression might be involved in the pathogenesis of the oral lichen planus through increasing lymphatic vessels and lymphangiogenesis. Creative Commons Attribution License

  17. VEGFR-3 Expression in Oral Lichen Planus

    PubMed Central

    Saravi, Zahra Zolfaghari; Seyedmajidi, Maryam; Sharbatdaran, Majid; Bijani, Ali; Mozaffari, Fatemeh; Aminishakib, Pouyan

    2017-01-01

    Background and objective: Given the postulated the role of inflammation and possible contribution of lymphangiogenesis in oral lichen planus, this study aimed to assess any associated presence of VEGFR-3. Material and Methods: This cross-sectional study was performed on 52 formalin fixed and paraffin embedded blocks of oral lichen planus (pathological diagnosis based on Modified WHO criteria), comprising 25 of erosive and 27 of reticular type, along with 60 samples of normal mucosa (with minimal inflammation from clinical and histopathological aspects) obtained at crown lengthening surgery. Four micron sections were cut from paraffin blocks and stained with H and E for confirmation of diagnosis and by immunohistochemistry with primary antibodies against VEGFR-3. Negative controls were provided by omission of primary antibody and placenta was considered as a positive control. Data were analyzed by Chi-square, Mann-Whitney and Kruskal-wallis tests and P <0.05 was considered statistically significant. Findings: VEGFR-3 expression was apparent in 61.5% of lichen planus specimens and 5% of those from normal mucosa (p<0.001). Also, the average number of stained vessels was significantly higher in oral lichen planus than in normal mucosa (p<0.001). VEGFR-3 expression in oral lichen planus (p=0.262) and the average number of stained vessels (p=0.092) demonstrated no significant difference according to the type. Conclusion: It appears that VEGFR-3 expression might be involved in the pathogenesis of the oral lichen planus through increasing lymphatic vessels and lymphangiogenesis. PMID:28345335

  18. Bioresorbable pins and interference screws for fixation of hamstring tendon grafts in anterior cruciate ligament reconstruction surgery: a randomized controlled trial.

    PubMed

    Stengel, Dirk; Casper, Dirk; Bauwens, Kai; Ekkernkamp, Axel; Wich, Michael

    2009-09-01

    Biodegradable cross-pins have been shown to provide higher failure loads than do screws for fixation of hamstring tendons under laboratory conditions. To compare the clinical results of biodegradable pins (RigidFix) and interference screws (BioCryl) for fixation of hamstring grafts in arthroscopically assisted anterior cruciate ligament reconstruction. Study Design Randomized controlled trial; Level of evidence, 1. To test the hypothesis of a difference of 1.0 +/- 1.2 mm in anterior knee laxity between the two fixation options, 54 patients were randomly assigned to groups via a block randomization scheme and sealed envelopes. All patients underwent standardized hamstring graft reconstruction and had similar postoperative aftercare by an accelerated rehabilitation protocol. Measures assessed at baseline and after 1 and 2 years of follow-up included (1) the side-to-side difference in anterior laxity (KT-1000 arthrometer), (2) Short Form 36 physical and mental component scores, and (3) the International Knee Documentation Committee form scores. After 1 and 2 years, 26 and 21 patients in the BioCryl group and 28 and 24 patients in the RigidFix group were available for follow-up examination. No significant difference was noted in instrumented anterior translation between BioCryl and RigidFix fixation: 1 year, 0.11 (95% CI, -0.60 to 0.82; P = .7537); 2 years, 0.33 (95% CI, -0.43 to 1.08 mm; P = .3849). Also, there were no significant differences in the mean physical and mental component scores and International Knee Documentation Committee form scores and in overall complication and surgical revision rates. A pin dislocation was classified as the sole procedure-specific serious adverse event. Bioresorbable pins do not provide better clinical results than do resorbable interference screws for hamstring graft fixation in anterior cruciate ligament reconstruction surgery.

  19. Fuel control for gas turbine engines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stearns, C.F.; Tutherly, H.W.

    1983-12-27

    The basic gas turbine engine hydromechanical fuel control is adaptable to different engine configurations such as turbofan, turboprop and turboshaft engines by incorporating in the main housing those elements having a commonality to all engine configurations and providing a removable block for each configuration having the necessary control elements and flow passages required for that particular configuration. That is to say, a block with the elements peculiar to a turbofan engine could be replaced by a mating block that includes those elements peculiar to a turboshaft engine in adapting the control for a turboshaft configuration. Similarly another block with thosemore » elements peculiar to a turboprop engine could replace any of the other blocks in adapting the control to a turboprop configuration. Obviously the basic control has the necessary flow passages terminating at the interface with the block and these flow passages mate with corresponding passages in the block.« less

  20. A survey of methods of feasible directions for the solution of optimal control problems

    NASA Technical Reports Server (NTRS)

    Polak, E.

    1972-01-01

    Three methods of feasible directions for optimal control are reviewed. These methods are an extension of the Frank-Wolfe method, a dual method devised by Pironneau and Polack, and a Zontendijk method. The categories of continuous optimal control problems are shown as: (1) fixed time problems with fixed initial state, free terminal state, and simple constraints on the control; (2) fixed time problems with inequality constraints on both the initial and the terminal state and no control constraints; (3) free time problems with inequality constraints on the initial and terminal states and simple constraints on the control; and (4) fixed time problems with inequality state space contraints and constraints on the control. The nonlinear programming algorithms are derived for each of the methods in its associated category.

  1. Modeling reactive nitrogen in North America: recent ...

    EPA Pesticide Factsheets

    Nitrogen is an essential building block of all proteins and thus an essential nutrient for all life. The bulk of nitrogen in the environment is tightly bound as non-reactive N2. Reactive nitrogen, which is naturally produced via enzymatic reactions, forest fires and lightning, is continually recycled and cascades through air, water, and soil media (Galloway et al., 2003). Human activity has perturbed this cycle through the combustion of fossil fuels and synthesis of fertilizers. The anthropogenic contribution to this cycle is now larger than natural sources in the United States and globally (Galloway et al., 2004). Reactive nitrogen enters the biosphere primarily from emissions of oxidized nitrogen to the atmosphere from combustion sources, as inorganic fertilizer applied to crops as reduced nitrogen fixed from atmospheric N2 through the Haber-Bosch process, as organic fertilizers such as manure, and through the cultivation of nitrogen fixing crops (Canfield et al., 2010). Both the United States (US) Clean Air Act and the Canadian Environmental Protection Act (CEPA) have substantially reduced the emissions of oxidized nitrogen in North America through NOx controls on smokestacks and exhaust pipes (Sickles and Shadwick, 2015; AQA, 2015). However, reduced nitrogen emissions have remained constant during the last few decades of emission reductions. The National Exposure Research Laboratory’s Atmospheric Modeling Division (AMAD) c

  2. Label-free protein profiling of formalin-fixed paraffin-embedded (FFPE) heart tissue reveals immediate mitochondrial impairment after ionising radiation.

    PubMed

    Azimzadeh, Omid; Scherthan, Harry; Yentrapalli, Ramesh; Barjaktarovic, Zarko; Ueffing, Marius; Conrad, Marcus; Neff, Frauke; Calzada-Wack, Julia; Aubele, Michaela; Buske, Christian; Atkinson, Michael J; Hauck, Stefanie M; Tapio, Soile

    2012-04-18

    Qualitative proteome profiling of formalin-fixed, paraffin-embedded (FFPE) tissue is advancing the field of clinical proteomics. However, quantitative proteome analysis of FFPE tissue is hampered by the lack of an efficient labelling method. The usage of conventional protein labelling on FFPE tissue has turned out to be inefficient. Classical labelling targets lysine residues that are blocked by the formalin treatment. The aim of this study was to establish a quantitative proteomics analysis of FFPE tissue by combining the label-free approach with optimised protein extraction and separation conditions. As a model system we used FFPE heart tissue of control and exposed C57BL/6 mice after total body irradiation using a gamma ray dose of 3 gray. We identified 32 deregulated proteins (p≤0.05) in irradiated hearts 24h after the exposure. The proteomics data were further evaluated and validated by bioinformatics and immunoblotting investigation. In good agreement with our previous results using fresh-frozen tissue, the analysis indicated radiation-induced alterations in three main biological pathways: respiratory chain, lipid metabolism and pyruvate metabolism. The label-free approach enables the quantitative measurement of radiation-induced alterations in FFPE tissue and facilitates retrospective biomarker identification using clinical archives. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Infinite-disorder critical points of models with stretched exponential interactions

    NASA Astrophysics Data System (ADS)

    Juhász, Róbert

    2014-09-01

    We show that an interaction decaying as a stretched exponential function of distance, J(l)˜ e-cl^a , is able to alter the universality class of short-range systems having an infinite-disorder critical point. To do so, we study the low-energy properties of the random transverse-field Ising chain with the above form of interaction by a strong-disorder renormalization group (SDRG) approach. We find that the critical behavior of the model is controlled by infinite-disorder fixed points different from those of the short-range model if 0 < a < 1/2. In this range, the critical exponents calculated analytically by a simplified SDRG scheme are found to vary with a, while, for a > 1/2, the model belongs to the same universality class as its short-range variant. The entanglement entropy of a block of size L increases logarithmically with L at the critical point but, unlike the short-range model, the prefactor is dependent on disorder in the range 0 < a < 1/2. Numerical results obtained by an improved SDRG scheme are found to be in agreement with the analytical predictions. The same fixed points are expected to describe the critical behavior of, among others, the random contact process with stretched exponentially decaying activation rates.

  4. Wavelet-based Encoding Scheme for Controlling Size of Compressed ECG Segments in Telecardiology Systems.

    PubMed

    Al-Busaidi, Asiya M; Khriji, Lazhar; Touati, Farid; Rasid, Mohd Fadlee; Mnaouer, Adel Ben

    2017-09-12

    One of the major issues in time-critical medical applications using wireless technology is the size of the payload packet, which is generally designed to be very small to improve the transmission process. Using small packets to transmit continuous ECG data is still costly. Thus, data compression is commonly used to reduce the huge amount of ECG data transmitted through telecardiology devices. In this paper, a new ECG compression scheme is introduced to ensure that the compressed ECG segments fit into the available limited payload packets, while maintaining a fixed CR to preserve the diagnostic information. The scheme automatically divides the ECG block into segments, while maintaining other compression parameters fixed. This scheme adopts discrete wavelet transform (DWT) method to decompose the ECG data, bit-field preserving (BFP) method to preserve the quality of the DWT coefficients, and a modified running-length encoding (RLE) scheme to encode the coefficients. The proposed dynamic compression scheme showed promising results with a percentage packet reduction (PR) of about 85.39% at low percentage root-mean square difference (PRD) values, less than 1%. ECG records from MIT-BIH Arrhythmia Database were used to test the proposed method. The simulation results showed promising performance that satisfies the needs of portable telecardiology systems, like the limited payload size and low power consumption.

  5. Photomixotrophic chemical production in cyanobacteria.

    PubMed

    Matson, Morgan M; Atsumi, Shota

    2018-04-01

    The current global dependence on fossil fuels for both energy and chemical production has spurred concerns regarding long-term resource security and environmental detriments resulting from increased CO 2 levels. Through the installation of exogenous metabolic pathways, engineered cyanobacteria strains can directly fix CO 2 into industrially relevant chemicals currently produced from petroleum. This review highlights some of the studies that have successfully implemented photomixotrophic conditions to increase cyanobacterial chemical production. Supplementation with fixed carbon sources provides additional carbon building blocks and energy to enhance production and occasionally aid in growth. Photomixotrophic production has increased titers up to 5-fold over traditional autotrophic conditions, demonstrating promising applications for future commercialization. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Bi-Frequency Modulated Quasi-Resonant Converters: Theory and Applications

    NASA Astrophysics Data System (ADS)

    Zhang, Yuefeng

    1995-01-01

    To avoid the variable frequency operation of quasi -resonant converters, many soft-switching PWM converters have been proposed, all of them require an auxiliary switch, which will increase the cost and complexity of the power supply system. In this thesis, a new kind of technique for quasi -resonant converters has been proposed, which is called the bi-frequency modulation technique. By operating the quasi-resonant converters at two switching frequencies, this technique enables quasi-resonant converters to achieve the soft-switching, at fixed switching frequencies, without an auxiliary switch. The steady-state analysis of four commonly used quasi-resonant converters, namely, ZVS buck, ZCS buck, ZVS boost, and ZCS boost converter has been presented. Using the concepts of equivalent sources, equivalent sinks, and resonant tank, the large signal models of these four quasi -resonant converters were developed. Based on these models, the steady-state control characteristics of BFM ZVS buck, BFM ZCS buck, BFM ZVS boost, and BFM ZCS boost converter have been derived. The functional block and design consideration of the bi-frequency controller were presented, and one of the implementations of the bi-frequency controller was given. A complete design example has been presented. Both computer simulations and experimental results have verified that the bi-frequency modulated quasi-resonant converters can achieve soft-switching, at fixed switching frequencies, without an auxiliary switch. One of the application of bi-frequency modulation technique is for EMI reduction. The basic principle of using BFM technique for EMI reduction was introduced. Based on the spectral analysis, the EMI performances of the PWM, variable-frequency, and bi-frequency modulated control signals was evaluated, and the BFM control signals show the lowest EMI emission. The bi-frequency modulated technique has also been applied to the power factor correction. A BFM zero -current switching boost converter has been designed for the power factor correction, and the simulation results show that the power factor has been improved.

  7. Fault Tolerant Cache Schemes

    NASA Astrophysics Data System (ADS)

    Tu, H.-Yu.; Tasneem, Sarah

    Most of modern microprocessors employ on—chip cache memories to meet the memory bandwidth demand. These caches are now occupying a greater real es tate of chip area. Also, continuous down scaling of transistors increases the possi bility of defects in the cache area which already starts to occupies more than 50% of chip area. For this reason, various techniques have been proposed to tolerate defects in cache blocks. These techniques can be classified into three different cat egories, namely, cache line disabling, replacement with spare block, and decoder reconfiguration without spare blocks. This chapter examines each of those fault tol erant techniques with a fixed typical size and organization of L1 cache, through extended simulation using SPEC2000 benchmark on individual techniques. The de sign and characteristics of each technique are summarized with a view to evaluate the scheme. We then present our simulation results and comparative study of the three different methods.

  8. Implementation of the block-Krylov boundary flexibility method of component synthesis

    NASA Technical Reports Server (NTRS)

    Carney, Kelly S.; Abdallah, Ayman A.; Hucklebridge, Arthur A.

    1993-01-01

    A method of dynamic substructuring is presented which utilizes a set of static Ritz vectors as a replacement for normal eigenvectors in component mode synthesis. This set of Ritz vectors is generated in a recurrence relationship, which has the form of a block-Krylov subspace. The initial seed to the recurrence algorithm is based on the boundary flexibility vectors of the component. This algorithm is not load-dependent, is applicable to both fixed and free-interface boundary components, and results in a general component model appropriate for any type of dynamic analysis. This methodology was implemented in the MSC/NASTRAN normal modes solution sequence using DMAP. The accuracy is found to be comparable to that of component synthesis based upon normal modes. The block-Krylov recurrence algorithm is a series of static solutions and so requires significantly less computation than solving the normal eigenspace problem.

  9. Laboratory testing of a building envelope segment based on cellular concrete

    NASA Astrophysics Data System (ADS)

    Fořt, Jan; Pavlík, Zbyšek; Černý, Robert

    2016-07-01

    Hygrothermal performance of a building envelope based on cellular concrete blocks is studied in the paper. Simultaneously, the strain fields induced by the heat and moisture changes are monitored. The studied wall is exposed to the climatic load corresponding to the winter climatic conditions of the moderate year for Prague. The winter climatic exposure is chosen in order to simulate the critical conditions of the building structure from the point of view of material performance and temperature and humidity loading. The evaluation of hygrothermal performance of a researched wall is done on the basis of relative humidity and temperature profiles measured along the cross section of the cellular concrete blocks. Strain gauges are fixed on the wall surface in expected orientation of the blocks expansion. The obtained results show a good hygrothermal function of the analyzed cellular concrete wall and its insignificant strain.

  10. Adaptive fixed-time control for cluster synchronisation of coupled complex networks with uncertain disturbances

    NASA Astrophysics Data System (ADS)

    Jiang, Shengqin; Lu, Xiaobo; Cai, Guoliang; Cai, Shuiming

    2017-12-01

    This paper focuses on the cluster synchronisation problem of coupled complex networks with uncertain disturbances under an adaptive fixed-time control strategy. To begin with, complex dynamical networks with community structure which are subject to uncertain disturbances are taken into account. Then, a novel adaptive control strategy combined with fixed-time techniques is proposed to guarantee the nodes in the communities to desired states in a settling time. In addition, the stability of complex error systems is theoretically proved based on Lyapunov stability theorem. At last, two examples are presented to verify the effectiveness of the proposed adaptive fixed-time control.

  11. Reclamation of Synthetic Turbine Engine Lubricants.

    DTIC Science & Technology

    1981-08-01

    test in which the comparison of lubricants is based upon differences in degradation levels produced under a fixed time/temperature condition. Referring...release; distribution unlimited 17. DISTRIBUTION STATEMENT (of the abstract entered in Block 20, II different from Report) 18 SUPPLEMENTARY NOTES 19 KEY...plant. Division in this respect was entirely fortuitous, depending only upon convenience in handling and inspecting the barrels at different delivery

  12. Integrating Syntax, Semantics, and Discourse DARPA Natural Language Understanding Program. Volume 1. Technical Report

    DTIC Science & Technology

    1989-09-30

    26 9.1 Overview of SPQR ............................................................................. 26 9.2...domain. The ISR is the input to the selection component SPQR , whose function is to block semantically anomalous parses before they are sent to the...frequently occurring pairs of words, which is useful for identifying fixed multi-word expressions. 9. SELECTION The SPQR module (Selectional Pattern

  13. Shuttle mission simulator baseline definition report, volume 2

    NASA Technical Reports Server (NTRS)

    Dahlberg, A. W.; Small, D. E.

    1973-01-01

    The baseline definition report for the space shuttle mission simulator is presented. The subjects discussed are: (1) the general configurations, (2) motion base crew station, (3) instructor operator station complex, (4) display devices, (5) electromagnetic compatibility, (6) external interface equipment, (7) data conversion equipment, (8) fixed base crew station equipment, and (9) computer complex. Block diagrams of the supporting subsystems are provided.

  14. Optimization of Single- and Dual-Color Immunofluorescence Protocols for Formalin-Fixed, Paraffin-Embedded Archival Tissues.

    PubMed

    Kajimura, Junko; Ito, Reiko; Manley, Nancy R; Hale, Laura P

    2016-02-01

    Performance of immunofluorescence staining on archival formalin-fixed paraffin-embedded human tissues is generally not considered to be feasible, primarily due to problems with tissue quality and autofluorescence. We report the development and application of procedures that allowed for the study of a unique archive of thymus tissues derived from autopsies of individuals exposed to atomic bomb radiation in Hiroshima, Japan in 1945. Multiple independent treatments were used to minimize autofluorescence and maximize fluorescent antibody signals. Treatments with NH3/EtOH and Sudan Black B were particularly useful in decreasing autofluorescent moieties present in the tissue. Deconvolution microscopy was used to further enhance the signal-to-noise ratios. Together, these techniques provide high-quality single- and dual-color fluorescent images with low background and high contrast from paraffin blocks of thymus tissue that were prepared up to 60 years ago. The resulting high-quality images allow the application of a variety of image analyses to thymus tissues that previously were not accessible. Whereas the procedures presented remain to be tested for other tissue types and archival conditions, the approach described may facilitate greater utilization of older paraffin block archives for modern immunofluorescence studies. © 2016 The Histochemical Society.

  15. 47 CFR 90.7 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    .... A regularly interacting group of base, mobile and associated control and fixed relay stations... qualify as unrestricted. Control point. Any place from which a transmitter's functions may be controlled. Control station. An Operational Fixed Station, the transmissions of which are used to control...

  16. 47 CFR 90.7 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    .... A regularly interacting group of base, mobile and associated control and fixed relay stations... qualify as unrestricted. Control point. Any place from which a transmitter's functions may be controlled. Control station. An Operational Fixed Station, the transmissions of which are used to control...

  17. Metabolic control analysis of developing oilseed rape (Brassica napus cv Westar) embryos shows that lipid assembly exerts significant control over oil accumulation.

    PubMed

    Tang, Mingguo; Guschina, Irina A; O'Hara, Paul; Slabas, Antoni R; Quant, Patti A; Fawcett, Tony; Harwood, John L

    2012-10-01

    Metabolic control analysis allows the study of metabolic regulation. We applied both single- and double-manipulation top-down control analysis to examine the control of lipid accumulation in developing oilseed rape (Brassica napus) embryos. The biosynthetic pathway was conceptually divided into two blocks of reactions (fatty acid biosynthesis (Block A), lipid assembly (Block B)) connected by a single system intermediate, the acyl-coenzyme A (acyl-CoA) pool. Single manipulation used exogenous oleate. Triclosan was used to inhibit specifically Block A, whereas diazepam selectively manipulated flux through Block B. Exogenous oleate inhibited the radiolabelling of fatty acids from [1-(14)C]acetate, but stimulated that from [U-14C]glycerol into acyl lipids. The calculation of group flux control coefficients showed that c. 70% of the metabolic control was in the lipid assembly block of reactions. Monte Carlo simulations gave an estimation of the error of the resulting group flux control coefficients as 0.27±0.06 for Block A and 0.73±0.06 for Block B. The two methods of control analysis gave very similar results and showed that Block B reactions were more important under our conditions. This contrasts notably with data from oil palm or olive fruit cultures and is important for efforts to increase oilseed rape lipid yields. © 2012 The Authors. New Phytologist © 2012 New Phytologist Trust.

  18. THE EFFECTS OF FIXED VERSUS ESCALATING REINFORCEMENT SCHEDULES ON SMOKING ABSTINENCE

    PubMed Central

    Romanowich, Paul; Lamb, R. J.

    2015-01-01

    Studies indicate that when abstinence is initiated, escalating reinforcement schedules maintain continuous abstinence longer than fixed reinforcement schedules. However, these studies were conducted for shorter durations than most clinical trials and also resulted in larger reinforcer value for escalating participants during the 1st week of the experiment. We tested whether escalating reinforcement schedules maintained abstinence longer than fixed reinforcement schedules in a 12-week clinical trial. Smokers (146) were randomized to an escalating reinforcement schedule, a fixed reinforcement schedule, or a control condition. Escalating reinforcement participants received $5.00 for their first breath carbon monoxide (CO) sample <3 ppm, with a $0.50 increase for each consecutive sample. Fixed reinforcement participants received $19.75 for each breath CO sample <3 ppm. Control participants received payments only for delivering a breath CO sample. Similar proportions of escalating and fixed reinforcement participants met the breath CO criterion at least once. Escalating reinforcement participants maintained criterion breath CO levels longer than fixed reinforcement and control participants. Similar to previous short-term studies, escalating reinforcement schedules maintained longer durations of abstinence than fixed reinforcement schedules during a clinical trial. PMID:25640764

  19. CO2 laser and/or fluoride enamel treatment against in situ/ex vivo erosive challenge.

    PubMed

    Jordão, Maísa Camillo; Forti, Gustavo Manzano; Navarro, Ricardo Scarparo; Freitas, Patrícia Moreira; Honório, Heitor Marques; Rios, Daniela

    2016-01-01

    This in situ/ex vivo study investigated the effect of CO2 laser irradiation and acidulated phosphate fluoride gel (APF) application, separately and in combination, on enamel resistance to erosion. During 2 experimental 5-day crossover phases, 8 volunteers wore intraoral appliances containing bovine enamel blocks which were submitted to four groups: 1st phase - control, untreated and CO2 laser irradiation, 2nd phase - fluoride application and fluoride application before CO2 laser irradiation. Laser irradiation was performed at 10.6 µm wavelength, 5 µs pulse duration and 50 Hz frequency, with average power input and output of 2.3 W and 2.0 W, respectively (28.6 J/cm2). APF gel (1.23%F, pH 3.5) was applied on enamel surface with a microbrush and left on for 4 minutes. Then, the enamel blocks were fixed at the intraoral appliance level. The erosion was performed extraorally 4 times daily for 5 min in 150 mL of cola drink. Enamel loss was measured profilometrically after treatment and after the in situ phase. The data were tested using one-way Repeated Measures Anova and Tukey's test (p<0.05). CO2 laser alone (2.00±0.39 µm) did not show any significantly preventive effect against enamel erosion when compared with the control group (2.41±1.20 µm). Fluoride treated enamel, associated (1.50±0.30 µm) or not (1.47±0.63 µm) with laser irradiation, significantly differed from the control. The APF application decreased enamel wear; however, CO2 laser irradiation did not enhance fluoride ability to reduce enamel wear.

  20. The chronic infusion of hexamethonium and phenylephrine to effectively clamp sympathetic vasomotor tone. A novel approach.

    PubMed

    Collister, J P; Osborn, J W

    1999-11-01

    There are several ways to assess the sympathetic nervous system (i.e. , nerve recording, sympathectomy, etc.), each of which has its own limitations. The present study was conducted to establish a standard, testable chronic ganglionic blockade protocol with a fixed level of adrenergic vasomotor tone. Rats were instrumented with radio telemetry pressure transducers and venous catheters for continuous measurement of arterial pressure and infusion of pharmacologic agents, respectively. After 3 days of control measurements, rats were infused for 9 days with a continuous dose of the ganglionic blocking agent, hexamethonium and the alpha-adrenergic agonist, phenylephrine. In this way, sympathetic tone was effectively "clamped," which maintained a normal level of arterial pressure. Control pressure between hexamethonium + phenylephrine (HEX + PE) treated rats (101+/-2 mm Hg) and saline (VEHICLE) treated rats (101+/-2 mmHg) was not different. By day 9 of the infusion, there was no difference in arterial pressure between groups (VEHICLE: 101+/-3 mm Hg, HEX + PE: 103+/-3 mm Hg) or from the control period, although heart rate was significantly less in HEX + PE rats (VEHICLE: 406+/-9 beats/min vs. HEX + PE: 343+/-6 beats/min). The effectiveness of this technique was validated by measuring cardiac baroreceptor reflex sensitivity, as well as the pressor response to the direct ganglionic stimulating agent, 1, 1-dimethyl-4-phenylpiperazinium iodide (DMPP). Compared to VEHICLE rats, HEX + PE rats showed no tachycardic response to depressor stimuli and an absence of a pressor response to DMPP. We conclude that this protocol is a useful technique to chronically, yet reversibly, block the sympathetic nervous system in experimental settings.

  1. CO2 laser and/or fluoride enamel treatment against in situ/ex vivo erosive challenge

    PubMed Central

    JORDÃO, Maísa Camillo; FORTI, Gustavo Manzano; NAVARRO, Ricardo Scarparo; FREITAS, Patrícia Moreira; HONÓRIO, Heitor Marques; RIOS, Daniela

    2016-01-01

    ABSTRACT Objective This in situ/ex vivo study investigated the effect of CO2 laser irradiation and acidulated phosphate fluoride gel (APF) application, separately and in combination, on enamel resistance to erosion. Material and Methods During 2 experimental 5-day crossover phases, 8 volunteers wore intraoral appliances containing bovine enamel blocks which were submitted to four groups: 1st phase - control, untreated and CO2 laser irradiation, 2nd phase - fluoride application and fluoride application before CO2 laser irradiation. Laser irradiation was performed at 10.6 µm wavelength, 5 µs pulse duration and 50 Hz frequency, with average power input and output of 2.3 W and 2.0 W, respectively (28.6 J/cm2). APF gel (1.23%F, pH 3.5) was applied on enamel surface with a microbrush and left on for 4 minutes. Then, the enamel blocks were fixed at the intraoral appliance level. The erosion was performed extraorally 4 times daily for 5 min in 150 mL of cola drink. Enamel loss was measured profilometrically after treatment and after the in situ phase. The data were tested using one-way Repeated Measures Anova and Tukey's test (p<0.05). Results CO2 laser alone (2.00±0.39 µm) did not show any significantly preventive effect against enamel erosion when compared with the control group (2.41±1.20 µm). Fluoride treated enamel, associated (1.50±0.30 µm) or not (1.47±0.63 µm) with laser irradiation, significantly differed from the control. Conclusion The APF application decreased enamel wear; however, CO2 laser irradiation did not enhance fluoride ability to reduce enamel wear. PMID:27383703

  2. Approximate strip exchanging.

    PubMed

    Roy, Swapnoneel; Thakur, Ashok Kumar

    2008-01-01

    Genome rearrangements have been modelled by a variety of primitives such as reversals, transpositions, block moves and block interchanges. We consider such a genome rearrangement primitive Strip Exchanges. Given a permutation, the challenge is to sort it by using minimum number of strip exchanges. A strip exchanging move interchanges the positions of two chosen strips so that they merge with other strips. The strip exchange problem is to sort a permutation using minimum number of strip exchanges. We present here the first non-trivial 2-approximation algorithm to this problem. We also observe that sorting by strip-exchanges is fixed-parameter-tractable. Lastly we discuss the application of strip exchanges in a different area Optical Character Recognition (OCR) with an example.

  3. Effector-Triggered Immunity Determines Host Genotype-Specific Incompatibility in Legume-Rhizobium Symbiosis.

    PubMed

    Yasuda, Michiko; Miwa, Hiroki; Masuda, Sachiko; Takebayashi, Yumiko; Sakakibara, Hitoshi; Okazaki, Shin

    2016-08-01

    Symbiosis between legumes and rhizobia leads to the formation of N2-fixing root nodules. In soybean, several host genes, referred to as Rj genes, control nodulation. Soybean cultivars carrying the Rj4 gene restrict nodulation by specific rhizobia such as Bradyrhizobium elkanii We previously reported that the restriction of nodulation was caused by B. elkanii possessing a functional type III secretion system (T3SS), which is known for its delivery of virulence factors by pathogenic bacteria. In the present study, we investigated the molecular basis for the T3SS-dependent nodulation restriction in Rj4 soybean. Inoculation tests revealed that soybean cultivar BARC-2 (Rj4/Rj4) restricted nodulation by B. elkanii USDA61, whereas its nearly isogenic line BARC-3 (rj4/rj4) formed nitrogen-fixing nodules with the same strain. Root-hair curling and infection threads were not observed in the roots of BARC-2 inoculated with USDA61, indicating that Rj4 blocked B. elkanii infection in the early stages. Accumulation of H2O2 and salicylic acid (SA) was observed in the roots of BARC-2 inoculated with USDA61. Transcriptome analyses revealed that inoculation of USDA61, but not its T3SS mutant in BARC-2, induced defense-related genes, including those coding for hypersensitive-induced responsive protein, which act in effector-triggered immunity (ETI) in Arabidopsis. These findings suggest that B. elkanii T3SS triggers the SA-mediated ETI-type response in Rj4 soybean, which consequently blocks symbiotic interactions. This study revealed a common molecular mechanism underlying both plant-pathogen and plant-symbiont interactions, and suggests that establishment of a root nodule symbiosis requires the evasion or suppression of plant immune responses triggered by rhizobial effectors. © The Author 2016. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  4. Two-dimensional parallel array technology as a new approach to automated combinatorial solid-phase organic synthesis

    PubMed

    Brennan; Biddison; Frauendorf; Schwarcz; Keen; Ecker; Davis; Tinder; Swayze

    1998-01-01

    An automated, 96-well parallel array synthesizer for solid-phase organic synthesis has been designed and constructed. The instrument employs a unique reagent array delivery format, in which each reagent utilized has a dedicated plumbing system. An inert atmosphere is maintained during all phases of a synthesis, and temperature can be controlled via a thermal transfer plate which holds the injection molded reaction block. The reaction plate assembly slides in the X-axis direction, while eight nozzle blocks holding the reagent lines slide in the Y-axis direction, allowing for the extremely rapid delivery of any of 64 reagents to 96 wells. In addition, there are six banks of fixed nozzle blocks, which deliver the same reagent or solvent to eight wells at once, for a total of 72 possible reagents. The instrument is controlled by software which allows the straightforward programming of the synthesis of a larger number of compounds. This is accomplished by supplying a general synthetic procedure in the form of a command file, which calls upon certain reagents to be added to specific wells via lookup in a sequence file. The bottle position, flow rate, and concentration of each reagent is stored in a separate reagent table file. To demonstrate the utility of the parallel array synthesizer, a small combinatorial library of hydroxamic acids was prepared in high throughput mode for biological screening. Approximately 1300 compounds were prepared on a 10 μmole scale (3-5 mg) in a few weeks. The resulting crude compounds were generally >80% pure, and were utilized directly for high throughput screening in antibacterial assays. Several active wells were found, and the activity was verified by solution-phase synthesis of analytically pure material, indicating that the system described herein is an efficient means for the parallel synthesis of compounds for lead discovery. Copyright 1998 John Wiley & Sons, Inc.

  5. Horizontal Resorption of Fresh-Frozen Corticocancellous Bone Blocks in the Reconstruction of the Atrophic Maxilla at 5 Months

    PubMed Central

    Pereira, Eugénio; Messias, Ana; Dias, Ricardo; Judas, Fernando; Salvoni, Alexander; Guerra, Fernando

    2015-01-01

    Background Reliable implant-supported rehabilitation of an alveolar ridge needs sufficient volume of bone. In order to achieve a prosthetic-driven positioning, bone graft techniques may be required. Purpose This prospective cohort study aims to clinically evaluate the amount of resorption of corticocancellous fresh-frozen allografts bone blocks used in the reconstruction of the severe atrophic maxilla. Materials and Methods Twenty-two partial and totally edentulous patients underwent bone augmentation procedures with fresh-frozen allogenous blocks from the iliac crest under local anesthesia. Implants were inserted into the grafted sites after a healing period of 5 months. Final fixed prosthesis was delivered ± 4 months later. Ridge width analysis and measurements were performed with a caliper before and after grafting and at implant insertion. Bone biopsies were performed in 16 patients. Results A total of 98 onlay block allografts were used in 22 patients with an initial mean alveolar ridge width of 3.41 ± 1.36 mm. Early exposure of blocks was observed in four situations and one of these completely resorbed. Mean horizontal bone gain was 3.63 ± 1.28 mm (p < .01). Mean buccal bone resorption between allograph placement and the reopening stage was 0.49 ± 0.54 mm, meaning approximately 7.1% (95% confidence interval: [5.6%, 8.6%]) of total ridge width loss during the integration period. One hundred thirty dental implants were placed with good primary stability (≥ 30 Ncm). Four implants presented early failure before the prosthetic delivery (96.7% implant survival). All patients were successfully rehabilitated. Histomorphometric analysis revealed 20.9 ± 5.8% of vital bone in close contact to the remaining grafted bone. A positive strong correlation (adjusted R2 = 0.44, p = .003) was found between healing time and vital bone percentage. Conclusions Augmentation procedures performed using fresh-frozen allografts from the iliac crest are a suitable alternative in the reconstruction of the atrophic maxilla with low resorption rate at 5 months, allowing proper stability of dental implants followed by fixed prosthetic rehabilitation. PMID:25346211

  6. Contents of GPS Data Files

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, John P.; Carver, Matthew Robert; Norman, Benjamin

    There are no very detailed descriptions of most of these instruments in the literature – we will attempt to fix that problem in the future. The BDD instruments are described in [1]. One of the dosimeter instruments on CXD boxes is described in [2]. These documents (or web links to them) and a few others are in this directory tree. The cross calibration of the CXD electron data with RBSP is described in [3]. Each row in the data file contains the data from one time bin from a CXD or BDD instrument along with a variety of parameters derivedmore » from the data. Time steps are commandable but 4 minutes is a typical setting. These instruments are on many (but not all) GPS satellites which are currently in operation. The data come from either BDD instruments on GPS Block IIR satellites (SVN41 and 48), or else CXD-IIR instruments on GPS Block IIR and IIR-M satellites (SVN53-61) or CXD-IIF instruments on GPS block IIF satellites (SVN62-73). The CXD-IIR instruments on block IIR and IIR(M) satellites use the same design.« less

  7. PEST reduces bias in forced choice psychophysics.

    PubMed

    Taylor, M M; Forbes, S M; Creelman, C D

    1983-11-01

    Observers performed several different detection tasks using both the PEST adaptive psychophysical procedure and a fixed-level (method of constant stimuli) psychophysical procedure. In two experiments, PEST runs targeted at P (C) = 0.80 were immediately followed by fixed-level detection runs presented at the difficulty level resulting from the PEST run. The fixed-level runs yielded P (C) about 0.75. During the fixed-level runs, the probability of a correct response was greater when the preceding response was correct than when it was wrong. Observers, even highly trained ones, perform in a nonstationary manner. The sequential dependency data can be used to determine a lower bound for the observer's "true" capability when performing optimally; this lower bound is close to the PEST target, and well above the forced choice P (C). The observer's "true" capability is the measure used by most theories of detection performance. A further experiment compared psychometric functions obtained from a set of PEST runs using different targets with those obtained from blocks of fixed-level trials at different levels. PEST results were more stable across observers, performance at all but the highest signal levels was better with PEST, and the PEST psychometric functions had shallower slopes. We hypothesize that PEST permits the observer to keep track of what he is trying to detect, whereas in the fixed-level method performance is disrupted by memory failure. Some recently suggested "more virulent" versions of PEST may be subject to biases similar to those of the fixed-level procedures.(ABSTRACT TRUNCATED AT 250 WORDS)

  8. Development of an experimental variable temperature set-up for a temperature range from 2.2 K to 325 K for cost-effective temperature sensor calibration

    NASA Astrophysics Data System (ADS)

    Pal, Sandip; Kar, Ranjan; Mandal, Anupam; Das, Ananda; Saha, Subrata

    2017-05-01

    A prototype of a variable temperature insert has been developed in-house as a cryogenic thermometer calibration facility. It was commissioned in fulfilment of the very stringent requirements of the temperature control of the cryogenic system. The calibration facility is designed for calibrating industrial cryogenic thermometers that include a temperature sensor and the wires heat-intercept in the 2.2 K-325 K temperature range. The isothermal section of the calibration block onto which the thermometers are mounted is weakly linked with the temperature control zone mounted with cooling capillary coil and cryogenic heater. The connecting wires of the thermometer are thermally anchored with the support of the temperature insert. The calibration procedure begins once the temperature of the support is stabilized. Homogeneity of the calibration block’s temperature is established both by simulation and by cross-comparison of two calibrated sensors. The absolute uncertainty present in temperature measurement is calculated and found comparable with the measured uncertainty at different temperature points. Measured data is presented in comparison to the standard thermometers at fixed points and it is possible to infer that the absolute accuracy achieved is better than  ±0.5% of the reading in comparison to the fixed point temperature. The design and development of simpler, low cost equipment, and approach to analysis of the calibration results are discussed further in this paper, so that it can be easily devised by other researchers.

  9. GPS Block 2R Time Standard Assembly (TSA) architecture

    NASA Technical Reports Server (NTRS)

    Baker, Anthony P.

    1990-01-01

    The underlying philosophy of the Global Positioning System (GPS) 2R Time Standard Assembly (TSA) architecture is to utilize two frequency sources, one fixed frequency reference source and one system frequency source, and to couple the system frequency source to the reference frequency source via a sample data loop. The system source is used to provide the basic clock frequency and timing for the space vehicle (SV) and it uses a voltage controlled crystal oscillator (VCXO) with high short term stability. The reference source is an atomic frequency standard (AFS) with high long term stability. The architecture can support any type of frequency standard. In the system design rubidium, cesium, and H2 masers outputting a canonical frequency were accommodated. The architecture is software intensive. All VCXO adjustments are digital and are calculated by a processor. They are applied to the VCXO via a digital to analog converter.

  10. Computational analysis of species transport and electrochemical characteristics of a MOLB-type SOFC

    NASA Astrophysics Data System (ADS)

    Hwang, J. J.; Chen, C. K.; Lai, D. Y.

    A multi-physics model coupling electrochemical kinetics with fluid dynamics has been developed to simulate the transport phenomena in mono-block-layer built (MOLB) solid oxide fuel cells (SOFC). A typical MOLB module is composed of trapezoidal flow channels, corrugated positive electrode-electrolyte-negative electrode (PEN) plates, and planar inter-connecters. The control volume-based finite difference method is employed for calculation, which is based on the conservation of mass, momentum, energy, species, and electric charge. In the porous electrodes, the flow momentum is governed by a Darcy model with constant porosity and permeability. The diffusion of reactants follows the Bruggman model. The chemistry within the plates is described via surface reactions with a fixed surface-to-volume ratio, tortuosity and average pore size. Species transports as well as the local variations of electrochemical characteristics, such as overpotential and current density distributions in the electrodes of an MOLB SOFC, are discussed in detail.

  11. Identification and Reconfigurable Control of Impaired Multi-Rotor Drones

    NASA Technical Reports Server (NTRS)

    Stepanyan, Vahram; Krishnakumar, Kalmanje; Bencomo, Alfredo

    2016-01-01

    The paper presents an algorithm for control and safe landing of impaired multi-rotor drones when one or more motors fail simultaneously or in any sequence. It includes three main components: an identification block, a reconfigurable control block, and a decisions making block. The identification block monitors each motor load characteristics and the current drawn, based on which the failures are detected. The control block generates the required total thrust and three axis torques for the altitude, horizontal position and/or orientation control of the drone based on the time scale separation and nonlinear dynamic inversion. The horizontal displacement is controlled by modulating the roll and pitch angles. The decision making algorithm maps the total thrust and three torques into the individual motor thrusts based on the information provided by the identification block. The drone continues the mission execution as long as the number of functioning motors provide controllability of it. Otherwise, the controller is switched to the safe mode, which gives up the yaw control, commands a safe landing spot and descent rate while maintaining the horizontal attitude.

  12. Architectural Survey of Pence Elementary School, Fort Leonard Wood, Missouri

    DTIC Science & Technology

    2011-09-01

    classroom floors , replacement acoustical tile drop ceilings, both original pendent ceiling light fixtures and replacement light fixtures, replacement wood...fixed pane transoms above, original door hardware, acoustical tile drop-ceiling, asbestos tile floor , and a metal radiator cover (photos 38-40...119). The corridors have acoustical tile drop-ceilings, concrete block walls, and asbestos tile floors (photo 44). There are several push-pin cork

  13. Optimized hardware framework of MLP with random hidden layers for classification applications

    NASA Astrophysics Data System (ADS)

    Zyarah, Abdullah M.; Ramesh, Abhishek; Merkel, Cory; Kudithipudi, Dhireesha

    2016-05-01

    Multilayer Perceptron Networks with random hidden layers are very efficient at automatic feature extraction and offer significant performance improvements in the training process. They essentially employ large collection of fixed, random features, and are expedient for form-factor constrained embedded platforms. In this work, a reconfigurable and scalable architecture is proposed for the MLPs with random hidden layers with a customized building block based on CORDIC algorithm. The proposed architecture also exploits fixed point operations for area efficiency. The design is validated for classification on two different datasets. An accuracy of ~ 90% for MNIST dataset and 75% for gender classification on LFW dataset was observed. The hardware has 299 speed-up over the corresponding software realization.

  14. Quantum group spin nets: Refinement limit and relation to spin foams

    NASA Astrophysics Data System (ADS)

    Dittrich, Bianca; Martin-Benito, Mercedes; Steinhaus, Sebastian

    2014-07-01

    So far spin foam models are hardly understood beyond a few of their basic building blocks. To make progress on this question, we define analogue spin foam models, so-called "spin nets," for quantum groups SU(2)k and examine their effective continuum dynamics via tensor network renormalization. In the refinement limit of this coarse-graining procedure, we find a vast nontrivial fixed-point structure beyond the degenerate and the BF phase. In comparison to previous work, we use fixed-point intertwiners, inspired by Reisenberger's construction principle [M. P. Reisenberger, J. Math. Phys. (N.Y.) 40, 2046 (1999)] and the recent work [B. Dittrich and W. Kaminski, arXiv:1311.1798], as the initial parametrization. In this new parametrization fine-tuning is not required in order to flow to these new fixed points. Encouragingly, each fixed point has an associated extended phase, which allows for the study of phase transitions in the future. Finally we also present an interpretation of spin nets in terms of melonic spin foams. The coarse-graining flow of spin nets can thus be interpreted as describing the effective coupling between two spin foam vertices or space time atoms.

  15. 47 CFR 90.7 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... interacting group of base, mobile and associated control and fixed relay stations intended to provide land... one that does not qualify as unrestricted. Control point. Any place from which a transmitter's functions may be controlled. Control station. An Operational Fixed Station, the transmissions of which are...

  16. 47 CFR 90.7 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... interacting group of base, mobile and associated control and fixed relay stations intended to provide land... one that does not qualify as unrestricted. Control point. Any place from which a transmitter's functions may be controlled. Control station. An Operational Fixed Station, the transmissions of which are...

  17. 47 CFR 90.7 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... interacting group of base, mobile and associated control and fixed relay stations intended to provide land... one that does not qualify as unrestricted. Control point. Any place from which a transmitter's functions may be controlled. Control station. An Operational Fixed Station, the transmissions of which are...

  18. SITES OF LIPOPROTEIN LIPASE ACTIVITY IN ADIPOSE TISSUE PERFUSED WITH CHYLOMICRONS

    PubMed Central

    Blanchette-Mackie, E. Joan; Scow, Robert O.

    1971-01-01

    Lipoprotein lipase activity was studied in rat parametrial adipose tissue perfused with chylomicrons and in gelatin blocks containing postheparin plasma and chylomicrons. The tissues and blocks were fixed in glutaraldehyde and incubated in 0.035 M CaCl2-0.1 M Tris medium (pH 8.3) at 38°C. The doubly labeled chylomicron triglycerides (glycerol-3H and palmitate-14C) in the tissues and blocks were hydrolyzed during incubation to free fatty acids (FFA) and the FFA remained in the specimens; hydrolysis was inhibited by 0.004 M diethyl paranitrophenyl phosphate (E-600). Incubated blocks and tissue were treated with 0.05 M Pb(NO3)2, postfixed in OsO4, dehydrated with acetone, embedded in Epon, and examined by electron microscopy. The incubated blocks contained electronlucent areas and granular and laminar precipitates at sites of hydrolysis. Similar precipitates were found in incubated tissue, within vacuoles and microvesicles of capillary endothelium, and in the subendothelial space (between the endothelium and pericytes), but not in the capillary lumen or in or near fat cells. The cytochemical reaction was greatly reduced, in blocks and tissues incubated with E-600. It is concluded that plasma glycerides are hydrolyzed by lipoprotein lipase in capillary endothelial cells and in the subendothelial space of adipose tissue and that glycerides across the endothelial cells within a membrane-bounded system. PMID:4329521

  19. 47 CFR 90.473 - Operation of internal transmitter control systems through licensed fixed control points.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Operation of internal transmitter control systems through licensed fixed control points. 90.473 Section 90.473 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control...

  20. 47 CFR 90.473 - Operation of internal transmitter control systems through licensed fixed control points.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Operation of internal transmitter control systems through licensed fixed control points. 90.473 Section 90.473 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control...

  1. 47 CFR 90.473 - Operation of internal transmitter control systems through licensed fixed control points.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Operation of internal transmitter control systems through licensed fixed control points. 90.473 Section 90.473 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control...

  2. 47 CFR 90.473 - Operation of internal transmitter control systems through licensed fixed control points.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Operation of internal transmitter control systems through licensed fixed control points. 90.473 Section 90.473 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control...

  3. 47 CFR 90.473 - Operation of internal transmitter control systems through licensed fixed control points.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Operation of internal transmitter control systems through licensed fixed control points. 90.473 Section 90.473 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control...

  4. A comparison of the efficacy of fixed versus removable functional appliances in children with Class II malocclusion: A systematic review.

    PubMed

    Pacha, Moaiyad Moussa; Fleming, Padhraig S; Johal, Ama

    2016-12-01

    To systematically compare the efficacy of fixed and removable functional appliances in Class II malocclusion in terms of morphological and patient-centred outcomes. A comprehensive search of electronic databases without language or time restrictions was undertaken, applying a pre-specified search strategy. Supplementary electronic searching of orthodontics journals and references list of included studies was performed. Randomized (RCTs) and controlled (CCTs) clinical trials involving children under 16 years with Class II malocclusion and overjet more than 5mm were included. A range of clinician- and patient-centred outcomes were evaluated and compared. Risk of bias assessment was carried out using the Cochrane Collaboration tool. Only four clinical trials were found to meet our criteria, of which two were RCTs, comparing the Herbst and the Twin Block appliances. Two further CCTs, compared the Activator to the Forsus and the Twin Force Bite Corrector, respectively. One study was assessed to be at unclear and the remaining at high risk of bias, precluding meta-analysis. There was also significant clinical heterogeneity in terms of methodology, type of intervention and the measured outcomes. Both modalities were effective in correcting the overjet with little differences found in cephalometric changes and a shortage of data concerning patient-centred outcomes. There is little evidence concerning the relative effectiveness of fixed and functional appliances or in relation to patient experiences and perceptions of these treatment modalities. Further well-designed clinical trials assessing the relative merits of both clinician- and patient-centred outcomes are needed. © The Author 2015. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  5. Evaluation of a Blocked-Trials Procedure to Establish Complex Stimulus Control over Intraverbal Responses in Children with Autism

    ERIC Educational Resources Information Center

    Ingvarsson, Einar T.; Kramer, Rachel L.; Carp, Charlotte L.; Pétursdóttir, Anna I.; Macias, Heather

    2016-01-01

    We evaluated the use of a blocked-trials procedure to establish complex stimulus control over intraverbal responses. The participants were four young boys with a diagnosis of autism who had struggled to master intraverbals. The blocked-trials procedures involved presentation of stimuli in separate trial blocks. The trial blocks gradually reduced…

  6. Block copolymers from ionic liquids for the preparation of thin carbonaceous shells

    PubMed Central

    Hanif, Sadaf; Oschmann, Bernd; Spetter, Dmitri; Tahir, Muhammad Nawaz; Tremel, Wolfgang

    2017-01-01

    This paper describes the controlled radical polymerization of an ionic-liquid monomer by RAFT polymerization. This allows the control over the molecular weight of ionic liquid blocks in the range of 8000 and 22000 and of the block-copolymer synthesis. In this work we focus on block copolymers with an anchor block. They can be used to control the formation of TiO2 nanoparticles, which are functionalized thereafter with a block of ionic-liquid polymer. Pyrolysis of these polymer functionalized inorganic nanoparticles leads to TiO2 nanoparticles coated with a thin carbonaceous shell. Such materials may, e.g., be interesting as battery materials. PMID:28904612

  7. Block copolymers from ionic liquids for the preparation of thin carbonaceous shells.

    PubMed

    Hanif, Sadaf; Oschmann, Bernd; Spetter, Dmitri; Tahir, Muhammad Nawaz; Tremel, Wolfgang; Zentel, Rudolf

    2017-01-01

    This paper describes the controlled radical polymerization of an ionic-liquid monomer by RAFT polymerization. This allows the control over the molecular weight of ionic liquid blocks in the range of 8000 and 22000 and of the block-copolymer synthesis. In this work we focus on block copolymers with an anchor block. They can be used to control the formation of TiO 2 nanoparticles, which are functionalized thereafter with a block of ionic-liquid polymer. Pyrolysis of these polymer functionalized inorganic nanoparticles leads to TiO 2 nanoparticles coated with a thin carbonaceous shell. Such materials may, e.g., be interesting as battery materials.

  8. The application of CAD / CAM technology in Dentistry

    NASA Astrophysics Data System (ADS)

    Susic, I.; Travar, M.; Susic, M.

    2017-05-01

    Information and communication technologies have found their application in the healthcare sector, including the frameworks of modern dentistry. CAD / CAM application in dentistry is the process by which is attained finished dental restoration through fine milling process of ready ceramic blocks. CAD / CAM is an acronym of english words Computer-Aided-Design (CAD) / Computer-Aided-Manufacture (CAM), respectively dental computer aided design and computer aided manufacture of inlays, onlays, crowns and bridges. CAD / CAM technology essentially allows you to create a two-dimensional and three-dimensional models and their materialization by numerical controlled machines. In order to operate more efficiently, reduce costs, increase user/patient satisfaction and ultimately achieve profits, many dental offices in the world have their attention focused on implementation of modern IT solutions in everyday practice. In addition to the specialized clinic management software, inventory control, etc., or hardware such as the use of lasers in cosmetic dentistry or intraoral scanning, recently the importance is given to the application of CAD / CAM technology in the field of prosthetic. After the removal of pathologically altered tooth structure, it is necessary to achieve restoration that will be most similar to the anatomy of a natural tooth. Applying CAD / CAM technology on applicable ceramic blocks it can be obtained very quick, but also very accurate restoration, in the forms of inlays, onlays, bridges and crowns. The paper presents the advantages of using this technology as well as satisfaction of the patients and dentists by using systems as: Cercon, Celay, Cerec, Lava, Everest, which represent imperative of modern dentistry in creating fixed dental restorations.

  9. Self-assembly assisted polymerization (SAAP): approaching long multi-block copolymers with an ordered chain sequence and controllable block length.

    PubMed

    Wu, Chi; Xie, Zuowei; Zhang, Guangzhao; Zi, Guofu; Tu, Yingfeng; Yang, Yali; Cai, Ping; Nie, Ting

    2002-12-07

    A combination of polymer physics and synthetic chemistry has enabled us to develop self-assembly assisted polymerization (SAAP), leading to the preparation of long multi-block copolymers with an ordered chain sequence and controllable block lengths.

  10. Fabrication of honeycomb-structured poly(ethylene glycol)-block-poly(lactic acid) porous films and biomedical applications for cell growth

    NASA Astrophysics Data System (ADS)

    Yao, Bingjian; Zhu, Qingzeng; Yao, Linli; Hao, Jingcheng

    2015-03-01

    A series of poly(ethylene glycol)-block-poly(lactic acid) (PEG-PLA) copolymers with a hydrophobic PLA block of different molecular weights and a fixed length hydrophilic PEG were synthesized successfully and characterized. These amphiphilic block copolymers were used to fabricate honeycomb-structured porous films using the breath figure (BF) templating technique. The surface topology and composition of the highly ordered pattern film were further characterized by scanning electron microscopy (SEM), atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS) and fluorescence microscopy. The results indicated that the PEG-to-PLA block molecular weight ratio influenced the BF film surface topology. The film with the best ordered pores was obtained with a PEG-to-PLA ratio of 2.0 × 103:3.0 × 104. The self-organization of the hydrophilic PEG chains within the pores was confirmed by XPS and fluorescence labeled PEG. A model is proposed to elucidate the stabilization process of the amphiphilic PEG-PLA aggregated architecture on the water droplet-based templates. In addition, GFP-U87 cell viability has been investigated by MTS test and the cell morphology on the honeycomb-structured PEG-PLA porous film has been evaluated using phase-contrast microscope. This porous film is shown to be suitable as a matrix for cell growth.

  11. Experimental Study on Properties of Methane Diffusion of Coal Block under Triaxial Compressive Stress

    PubMed Central

    Zhao, Hong-Bao

    2014-01-01

    Taking the standard size coal block samples defined by ISRM as research objects, both properties of methane diffusion of coal block under triaxial compressive stress and characteristic influences caused by methane pressure were systematically studied with thermo-fluid-solid coupling with triaxial servocontrolled seepage equipment of methane-containing coal. The result shows the methane diffusion property of coal block under triaxial compressive stress was shown in four-stage as follow, first is sharply reduce stage, second is hyperbolic reduce stage, third is close to a fixed value stage, fourth stage is 0. There is a special point making the reduced rate of characteristic curve of methane diffusion speed become sharply small; the influences of shape of methane diffusion speed characteristic curve caused by methane pressure are not obvious, which only is shown in numerical size of methane diffusion speed. Test time was extended required by appear of the special point makes the reduce rate of methane diffusion speed become sharply small. The fitting four-phase relation of methane diffusion of coal block under triaxial compressive stress was obtained, and the idea is proposed that influences of the fitting four-phase relation caused by methane pressure were only shown in value of fitting parameters. PMID:25531000

  12. Robust Control Design via Linear Programming

    NASA Technical Reports Server (NTRS)

    Keel, L. H.; Bhattacharyya, S. P.

    1998-01-01

    This paper deals with the problem of synthesizing or designing a feedback controller of fixed dynamic order. The closed loop specifications considered here are given in terms of a target performance vector representing a desired set of closed loop transfer functions connecting various signals. In general these point targets are unattainable with a fixed order controller. By enlarging the target from a fixed point set to an interval set the solvability conditions with a fixed order controller are relaxed and a solution is more easily enabled. Results from the parametric robust control literature can be used to design the interval target family so that the performance deterioration is acceptable, even when plant uncertainty is present. It is shown that it is possible to devise a computationally simple linear programming approach that attempts to meet the desired closed loop specifications.

  13. Fabrication of a mini multi-fixed-point cell for the calibration of industrial platinum resistance thermometers

    NASA Astrophysics Data System (ADS)

    Ragay-Enot, Monalisa; Lee, Young Hee; Kim, Yong-Gyoo

    2017-07-01

    A mini multi-fixed-point cell (length 118 mm, diameter 33 mm) containing three materials (In-Zn eutectic (mass fraction 3.8% Zn), Sn and Pb) in a single crucible was designed and fabricated for the easy and economical fixed-point calibration of industrial platinum resistance thermometers (IPRTs) for use in industrial temperature measurements. The melting and freezing behaviors of the metals were investigated and the phase transition temperatures were determined using a commercial dry-block calibrator. Results showed that the melting plateaus are generally easy to realize and are reproducible, flatter and of longer duration. On the other hand, the freezing process is generally difficult, especially for Sn, due to the high supercooling required to initiate freezing. The observed melting temperatures at optimum set conditions were 143.11 °C (In-Zn), 231.70 °C (Sn) and 327.15 °C (Pb) with expanded uncertainties (k  = 2) of 0.12 °C, 0.10 °C and 0.13 °C, respectively. This multi-fixed-point cell can be treated as a sole reference temperature-generating system. Based on the results, the realization of melting points of the mini multi-fixed-point cell can be recommended for the direct calibration of IPRTs in industrial applications without the need for a reference thermometer.

  14. Translatory shock absorber for attitude sensors

    NASA Technical Reports Server (NTRS)

    Vonpragenau, G. L.; Morgan, I. T., Jr.; Kirby, C. A. (Inventor)

    1976-01-01

    A translatory shock absorber is provided for mounting an attitude sensor thereon for isolating a sensor from translatory vibrations. The translatory shock absorber includes a hollow block structure formed as one piece to form a parallelogram. The absorber block structure includes a movable top plate for supporting the attitude sensor and a fixed base plate with opposed side plates interposed between. At the junctions of the side plates, and the base and top plates, there are provided grooves which act as flexible hinges for attenuating translatory vibrations. A damping material is supported on a pedestal which is carried on the base plate between the side plates thereof. The top of the damping material rests against the bottom surface of the top plate for eliminating the resonant peaks of vibration.

  15. Optimization of block-floating-point realizations for digital controllers with finite-word-length considerations.

    PubMed

    Wu, Jun; Hu, Xie-he; Chen, Sheng; Chu, Jian

    2003-01-01

    The closed-loop stability issue of finite-precision realizations was investigated for digital controllers implemented in block-floating-point format. The controller coefficient perturbation was analyzed resulting from using finite word length (FWL) block-floating-point representation scheme. A block-floating-point FWL closed-loop stability measure was derived which considers both the dynamic range and precision. To facilitate the design of optimal finite-precision controller realizations, a computationally tractable block-floating-point FWL closed-loop stability measure was then introduced and the method of computing the value of this measure for a given controller realization was developed. The optimal controller realization is defined as the solution that maximizes the corresponding measure, and a numerical optimization approach was adopted to solve the resulting optimal realization problem. A numerical example was used to illustrate the design procedure and to compare the optimal controller realization with the initial realization.

  16. Aircraft Pitch Control With Fixed Order LQ Compensators

    NASA Technical Reports Server (NTRS)

    Green, James; Ashokkumar, C. R.; Homaifar, Abdollah

    1997-01-01

    This paper considers a given set of fixed order compensators for aircraft pitch control problem. By augmenting compensator variables to the original state equations of the aircraft, a new dynamic model is considered to seek a LQ controller. While the fixed order compensators can achieve a set of desired poles in a specified region, LQ formulation provides the inherent robustness properties. The time response for ride quality is significantly improved with a set of dynamic compensators.

  17. Aircraft Pitch Control with Fixed Order LQ Compensators

    NASA Technical Reports Server (NTRS)

    Green, James; Ashokkumar, Cr.; Homaifar, A.

    1997-01-01

    This paper considers a given set of fixed order compensators for aircraft pitch control problem. By augmenting compensator variables to the original state equations of the aircraft, a new dynamic model is considered to seek a LQ controller. While the fixed order compensators can achieve a set of desired poles in a specified region, LQ formulation provides the inherent robustness properties. The time response for ride quality is significantly improved with a set of dynamic compensators.

  18. Controlled self-assembly of conjugated rod-coil block copolymers for applications in organic optoelectronics

    NASA Astrophysics Data System (ADS)

    Tao, Yuefei

    Organic electronics are of great interest in manufacturing light weight, mechanical flexible, and inexpensive large area devices. While significant improvements have been made over the last several years and it is now clear that morphology on the lengthscale of exciton diffusion (10nm) is of crucial importance, a clear relationship between structure and device properties has not emerged. This lack of understanding largely emerges from an inability to control morphology on this lengthscale. This thesis will center around an approach, based on block copolymer self-assembly, to generate equilibrium nanostructures on the 10 nm lengthscale of exciton diffusion and study their effects on device performance. Self-assembly of semiconducting block copolymers is complicated by the non-classical chain shape of conjugated polymers. Unlike classical polymers, the chains do not assume a Gaussian coil shape which is stretched near block copolymer interfaces, instead the chains are elongated and liquid crystalline. Previous work has demonstrated how these new molecular interactions and shapes control the phase diagram of so-called rod-coil block copolymers. Here, we will focus on controlling domain size, orientation, and chemical structure. While domain size can be controlled directly through molecular weight, this requires significant additional synthesis of domain size is to be varied. Here, the domain size is controlled by blending homopolymers into a self-assembling rod-coil block copolymer. When coil-like blocks are incorporated, the domains swell, as expected. When rod-like blocks are incorporated, they interdigitate with the rods of the block copolymers. This results in an increase in interfacial area which forces the coils to rearrange and an overall decrease in domain size with increasing rod content. Control over lamellar orientation is crucial in order to design and control charge transport pathways and exciton recombination or separation interfaces. While numerous techniques have been demonstrated for classical block copolymers, the pi conjugation in the rod blocks allow for additional control mechanisms. Liquid crystals are traditionally aligned in magnetic fields. Here, it is demonstrated that if the rod-like blocks are aligned unidirectionally, the block copolymer interfaces follow to create macroscopic alignment of the nanostructures. Organic Light Emitting Diodes (OLEDs) are generally composed of electron transporting and hole transporting moieties to balance charge recombination. Here, a new multifunctional bipolar rod-coil block copolymer containing the hole transporting and electron transporting materials is synthesized. Self-assembly of this new block copolymer results in 15nm lamellae oriented in grains both parallel and perpendicula to the anode. The self-assembled block copolymer shows superior device performance to controls consisting of a luminescent, analogous homopolymer, and a blend of the two component homopolymers. The effects of the morphologies and chemical structure on photovoltaics is explored with a rod-coil block copolymer, (poly(3-hexylthiophene-b-acrylic perylene)). By varying the kinetics of self-assembly through processing, the block copolymer can be disordered, ordered with only short range registry between the nanodomains, or with long-range order. The short range ordered samples showed the best device performance suggesting that the connectivity that is a biproduct of poor order is beneficial for device performance.

  19. Fixed-time stabilization of impulsive Cohen-Grossberg BAM neural networks.

    PubMed

    Li, Hongfei; Li, Chuandong; Huang, Tingwen; Zhang, Wanli

    2018-02-01

    This article is concerned with the fixed-time stabilization for impulsive Cohen-Grossberg BAM neural networks via two different controllers. By using a novel constructive approach based on some comparison techniques for differential inequalities, an improvement theorem of fixed-time stability for impulsive dynamical systems is established. In addition, based on the fixed-time stability theorem of impulsive dynamical systems, two different control protocols are designed to ensure the fixed-time stabilization of impulsive Cohen-Grossberg BAM neural networks, which include and extend the earlier works. Finally, two simulations examples are provided to illustrate the validity of the proposed theoretical results. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Donation return time at fixed and mobile donation sites

    PubMed Central

    Carey, Patricia M.; High, Patrick M.; Schlumpf, Karen S.; Johnson, Bryce R.; Mast, Alan E.; Rios, Jorge A.; Simon, Toby L.; Wilkinson, Susan L.

    2013-01-01

    BACKGROUND This study investigated the effect of blood donation environment, fixed or mobile with differing sponsor types, on donation return time. STUDY DESIGN AND METHODS Data from 2006 through 2009 at six US blood centers participating in the Retrovirus Epidemiology Donor Study-II (REDS-II) were used for analysis. Descriptive statistics stratified by whole blood (WB), plateletpheresis (PP), and double red blood cell (R2) donations were obtained for fixed and mobile locations, including median number of donations and median interdonation interval. A survival analysis estimated median return time at fixed and mobile sites, while controlling for censored return times, demographics, blood center, and mandatory recovery times. RESULTS Two-thirds (67.9%) of WB donations were made at mobile sites, 97.4% of PP donations were made at fixed sites, and R2 donations were equally distributed between fixed and mobile locations. For donations at fixed sites only or alternating between fixed and mobile sites, the highest median numbers of donations were nine and eight, respectively, and the shortest model-adjusted median return times (controlling for mandatory eligibility times of 56 and 112 days) were 36 and 30 days for WB and R2 donations, respectively. For PP donations, the shortest model-adjusted median return time was 23 days at a fixed location and the longest was 693 days at community locations. CONCLUSION WB, PP, and R2 donors with the shortest time between donations were associated with fixed locations and those alternating between fixed and mobile locations, even after controlling for differing mandatory recovery times for the different blood donation procedures. PMID:21745215

  1. Performance of data-compression codes in channels with errors. Final report, October 1986-January 1987

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1987-10-01

    Huffman codes, comma-free codes, and block codes with shift indicators are important candidate-message compression codes for improving the efficiency of communications systems. This study was undertaken to determine if these codes could be used to increase the thruput of the fixed very-low-frequency (FVLF) communication system. This applications involves the use of compression codes in a channel with errors.

  2. 49 CFR 236.401 - Automatic block signal system and interlocking standards applicable to traffic control systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Automatic block signal system and interlocking standards applicable to traffic control systems. 236.401 Section 236.401 Transportation Other Regulations... block signal system and interlocking standards applicable to traffic control systems. The standards...

  3. Role of T cells in the B-cell response: glutaraldehyde-fixed T-helper hybridoma cells synergize with the lymphokine IL-4 to induce B-cell activation and proliferation.

    PubMed

    Kubota, E; McKenzie, D T; Dutton, R W; Swain, S L

    1991-01-01

    Antigen-unselected helper T-cell hybridomas (Th) which activate normal resting B cells to RNA synthesis and proliferation in the presence of concanavalin A (Con A) have been developed. The response is completely Th cell dependent, and not restricted by the haplotype of the B-cell major histocompatibility complex (MHC). Culture supernatants from the Con A-stimulated Th hybridomas contain interleukin-4 (IL-4) and IL-2, but undetectable level of IL-5. The supernatant alone, however, does not induce B-cell activation or proliferation. Although the Con A-mediated Th cell-dependent B-cell response occurs in an MHC-unrestricted manner, the response of resting B cells can be blocked by monoclonal Ia antibody specific for the surface class II molecules of the responding B cell. The response is also blocked by monoclonal antibody to L3T4. Significant activation and proliferation of resting B cells can also be triggered by glutaraldehyde-fixed Th hybridomas and Con A when exogenous IL-4 is added. The stimulation with fixed Th hybridomas plus IL-4 can be inhibited by monoclonal anti-L3T4 or anti-Ia. These results suggest that maximal B-cell activation requires a direct helper T cell-B cell interaction which depends on availability of Ia on the B cell and L3T4 on the T cell, even when Con A overcomes the requirement for MHC-restricted T-cell recognition. We suggest that this signal, in conjunction with T-cell produced lymphokine IL-4, is responsible for the activation and subsequent proliferation of the B cells which occurs following interaction with T cells.

  4. Terahertz Imaging of Three-Dimensional Dehydrated Breast Cancer Tumors

    NASA Astrophysics Data System (ADS)

    Bowman, Tyler; Wu, Yuhao; Gauch, John; Campbell, Lucas K.; El-Shenawee, Magda

    2017-06-01

    This work presents the application of terahertz imaging to three-dimensional formalin-fixed, paraffin-embedded human breast cancer tumors. The results demonstrate the capability of terahertz for in-depth scanning to produce cross section images without the need to slice the tumor. Samples of tumors excised from women diagnosed with infiltrating ductal carcinoma and lobular carcinoma are investigated using a pulsed terahertz time domain imaging system. A time of flight estimation is used to obtain vertical and horizontal cross section images of tumor tissues embedded in paraffin block. Strong agreement is shown comparing the terahertz images obtained by electronically scanning the tumor in-depth in comparison with histopathology images. The detection of cancer tissue inside the block is found to be accurate to depths over 1 mm. Image processing techniques are applied to provide improved contrast and automation of the obtained terahertz images. In particular, unsharp masking and edge detection methods are found to be most effective for three-dimensional block imaging.

  5. A simple approach to characterizing block copolymer assemblies: graphene oxide supports for high contrast multi-technique imaging†

    PubMed Central

    Patterson, Joseph P.; Sanchez, Ana M.; Petzetakis, Nikos; Smart, Thomas P.; Epps, Thomas H.; Portman, Ian

    2013-01-01

    Block copolymers are well-known to self-assemble into a range of 3-dimensional morphologies. However, due to their nanoscale dimensions, resolving their exact structure can be a challenge. Transmission electron microscopy (TEM) is a powerful technique for achieving this, but for polymeric assemblies chemical fixing/staining techniques are usually required to increase image contrast and protect specimens from electron beam damage. Graphene oxide (GO) is a robust, water-dispersable, and nearly electron transparent membrane: an ideal support for TEM. We show that when using GO supports no stains are required to acquire high contrast TEM images and that the specimens remain stable under the electron beam for long periods, allowing sample analysis by a range of electron microscopy techniques. GO supports are also used for further characterization of assemblies by atomic force microscopy. The simplicity of sample preparation and analysis, as well as the potential for significantly increased contrast background, make GO supports an attractive alternative for the analysis of block copolymer assemblies. PMID:24049544

  6. Fixed Point Learning Based Intelligent Traffic Control System

    NASA Astrophysics Data System (ADS)

    Zongyao, Wang; Cong, Sui; Cheng, Shao

    2017-10-01

    Fixed point learning has become an important tool to analyse large scale distributed system such as urban traffic network. This paper presents a fixed point learning based intelligence traffic network control system. The system applies convergence property of fixed point theorem to optimize the traffic flow density. The intelligence traffic control system achieves maximum road resources usage by averaging traffic flow density among the traffic network. The intelligence traffic network control system is built based on decentralized structure and intelligence cooperation. No central control is needed to manage the system. The proposed system is simple, effective and feasible for practical use. The performance of the system is tested via theoretical proof and simulations. The results demonstrate that the system can effectively solve the traffic congestion problem and increase the vehicles average speed. It also proves that the system is flexible, reliable and feasible for practical use.

  7. Fixed-time synchronization of memristor-based BAM neural networks with time-varying discrete delay.

    PubMed

    Chen, Chuan; Li, Lixiang; Peng, Haipeng; Yang, Yixian

    2017-12-01

    This paper is devoted to studying the fixed-time synchronization of memristor-based BAM neural networks (MBAMNNs) with discrete delay. Fixed-time synchronization means that synchronization can be achieved in a fixed time for any initial values of the considered systems. In the light of the double-layer structure of MBAMNNs, we design two similar feedback controllers. Based on Lyapunov stability theories, several criteria are established to guarantee that the drive and response MBAMNNs can realize synchronization in a fixed time. In particular, by changing the parameters of controllers, this fixed time can be adjusted to some desired value in advance, irrespective of the initial values of MBAMNNs. Numerical simulations are included to validate the derived results. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Station Keeping of Small Outboard-Powered Boats

    NASA Technical Reports Server (NTRS)

    Fisher, A. D.; VanZwieten, J. H., Jr.; VanZwieten, T. S.

    2010-01-01

    Three station keeping controllers have been developed which work to minimize displacement of a small outboard-powered vessel from a desired location. Each of these three controllers has a common initial layer that uses fixed-gain feedback control to calculate the desired heading of the vessel. A second control layer uses a common fixed-gain feedback controller to calculate the net forward thrust, one of two algorithms for controlling engine angle (Fixed-Gain Proportional-integral-derivative (PID) or PID with Adaptively Augmented Gains), and one of two algorithms for differential throttle control (Fixed-Gain PID and PID with Adaptive Differential Throttle gains), which work together to eliminate heading error. The three selected controllers are evaluated using a numerical simulation of a 33-foot center console vessel with twin outboards that is subject to wave, wind, and current disturbances. Each controller is tested for its ability to maintain position in the presence of three sets of environmental disturbances. These algorithms were tested with current velocity of 1.5 m/s, significant wave height of 0.5 m, and wind speeds of 2, 5, and 10 m/s. These values were chosen to model conditions a small vessel may experience in the Gulf Stream off of Fort Lauderdale. The Fixed-gain PID controller progressively got worse as wind speeds increased, while the controllers using adaptive methodologies showed consistent performance over all weather conditions and decreased heading error by as much as 20%. Thus, enhanced robustness to environmental changes has been gained by using an adaptive algorithm.

  9. An investigation of fMRI time series stationarity during motor sequence learning foot tapping tasks.

    PubMed

    Muhei-aldin, Othman; VanSwearingen, Jessie; Karim, Helmet; Huppert, Theodore; Sparto, Patrick J; Erickson, Kirk I; Sejdić, Ervin

    2014-04-30

    Understanding complex brain networks using functional magnetic resonance imaging (fMRI) is of great interest to clinical and scientific communities. To utilize advanced analysis methods such as graph theory for these investigations, the stationarity of fMRI time series needs to be understood as it has important implications on the choice of appropriate approaches for the analysis of complex brain networks. In this paper, we investigated the stationarity of fMRI time series acquired from twelve healthy participants while they performed a motor (foot tapping sequence) learning task. Since prior studies have documented that learning is associated with systematic changes in brain activation, a sequence learning task is an optimal paradigm to assess the degree of non-stationarity in fMRI time-series in clinically relevant brain areas. We predicted that brain regions involved in a "learning network" would demonstrate non-stationarity and may violate assumptions associated with some advanced analysis approaches. Six blocks of learning, and six control blocks of a foot tapping sequence were performed in a fixed order. The reverse arrangement test was utilized to investigate the time series stationarity. Our analysis showed some non-stationary signals with a time varying first moment as a major source of non-stationarity. We also demonstrated a decreased number of non-stationarities in the third block as a result of priming and repetition. Most of the current literature does not examine stationarity prior to processing. The implication of our findings is that future investigations analyzing complex brain networks should utilize approaches robust to non-stationarities, as graph-theoretical approaches can be sensitive to non-stationarities present in data. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. 46 CFR 130.320 - Electronic position-fixing device.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Electronic position-fixing device. 130.320 Section 130... CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Navigational Equipment § 130.320 Electronic position-fixing device. Each vessel must be equipped with an electronic position-fixing device satisfactory for...

  11. 46 CFR 130.320 - Electronic position-fixing device.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Electronic position-fixing device. 130.320 Section 130... CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Navigational Equipment § 130.320 Electronic position-fixing device. Each vessel must be equipped with an electronic position-fixing device satisfactory for...

  12. 46 CFR 130.320 - Electronic position-fixing device.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Electronic position-fixing device. 130.320 Section 130... CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Navigational Equipment § 130.320 Electronic position-fixing device. Each vessel must be equipped with an electronic position-fixing device satisfactory for...

  13. 46 CFR 130.320 - Electronic position-fixing device.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Electronic position-fixing device. 130.320 Section 130... CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Navigational Equipment § 130.320 Electronic position-fixing device. Each vessel must be equipped with an electronic position-fixing device satisfactory for...

  14. 46 CFR 130.320 - Electronic position-fixing device.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Electronic position-fixing device. 130.320 Section 130... CONTROL, AND MISCELLANEOUS EQUIPMENT AND SYSTEMS Navigational Equipment § 130.320 Electronic position-fixing device. Each vessel must be equipped with an electronic position-fixing device satisfactory for...

  15. New geophysical electromagnetic method of archeological object research in Egypt

    NASA Astrophysics Data System (ADS)

    Hachay, O. A.; Khachay, O. Yu.; Attia, Magdi.

    2009-04-01

    The demand to the enhanced geophysical technique and device, in addition to the precise interpretation of the geophysical data, is the resolution of the geophysical complex research, especially by the absence of priory information about the researched place. Therefore, an approach to use the planshet method of electromagnetic induction in the frequency geometry was developed by Hachay. et al., 1997a, 1997b, 1999, 2000, 2002, and 2005. The method was adapted to map and monitor the high complicated geological mediums, to determine the structural factors and criteria of the rock massif in the mine subsurface. The field observation and the way of interpretation make the new technology differ from other known earlier methods of field raying or tomography (Hachay et al., 1997c, 1999, and 2000).The 3D geoelectrical medium research is based on the concept of three staged interpreting of the alternating electromagnetic field in a frame of the block-layered isotropic medium with inclusion (Hachay 1997a, and 2002); in the first stage, the geoelectrical parameters of the horizontal block-layered medium, which includes the heterogeneities, are defined. In the second stage a geometrical model of the different local heterogeneities or groups inside the block-layered medium is constructed based on the local geoelectrical heterogeneities produced from the first stage after filtering the anomalous fields plunged in the medium. While in the third stage, the surfaces of the searched heterogeneities could be calculated in account of the physical parameters of the anomalous objects.For practical realization of that conception the system of observation for alternating electromagnetic field with use of vertical magnetic dipole was elaborated. Such local source of excitation and regular net of observations allows realizing overlapping by different angles of observation directions. As incoming data for interpretation, three components of modules of three components of magnetic field are used. For the case on surface observations the data are measured on the Earth's surface at the set of distances between the source and receiver as a function of frequencies. The measurements of the module of three components of the magnetic field vertical and two horizontal: one directed to the source and second perpendicular to that direction are provided in the frame of planshet for the fixed net with fixed step and fixed length of the planshet's side. In the frame of profile observations the planshet become to a band or a line and the length of the band or the line is a base of observations or an array. For the variant of the wide profile (band) the source of excitation is located at the beginning of the array on the profile, which is parallel to the measuring profile. We shall call that a wide array. It moves systematically with a fixed step of meters. For the variant of an usual profile the source is located on the measuring profile and the moving of the oscillator is similar. For the variant of a planshet survey the source is located into the center of the planshet using the fixed net of observation. Then the planshet array moves systematically with overlapping usually on the half of the planshet.The interpretation is made in a frame of n-layered model for each array and planshet location. After that each point of the planshet is associated with one and only column of layers thicknesses and corresponding fixed column with resistance of the medium in that layers. Gathering information of all planshets together we obtain a many-valued function of each point - distribution of thicknesses and resistances of the medium layers. Then we calculate the average value for these distributions for each point of the observation set. Thus we obtain the unique distribution of thicknesses of horizontal layers and resistances, which corresponds to the medium model as a cylinder with vertical generatrixes and with a rectangle at the bottom and with a point of observation located in its center. Thus we change over layered model to a block-layered model. Then, gathering the values of thicknesses and resistances for all points of observation, located on one and the same profile we obtain the file of an average cross-section along the profile.The next step is combining the neighboring blocks with close-range values of resistance to one block. That operation is made according to the fixed scale of resistance. The second stage of interpretation is used to define the geometrical characteristics of conductive inclusions and their equivalent moments, which are proportional to the ratio of the conductivity difference in the host rock and in the inclusion to the conductivity in the host rock. Here the approximation principle is used for alternating electromagnetic fields. The initial model of the inclusion is a current line of fixed length. That approximation construction is used for fitting of the average parameter of geoelectrical heterogeneity, which is calculated and located to each point of the profile (Hachay O.A. et all. 2002).The first problem: to found the tomb of Ptolemey in Alexandria. That work is provided by NRIAG together with the Aphine University. The historical and archeological work was provided during a long time. In that moment when we had been asked to do our research on that object it must be needed to show more precisely the place of that tomb on the territory of the ancient royal garden in Alexandria. NRIAG had developed electro prospecting works using radar and vertical electric soundings. With use of our results on the archeological object it had been choose a more precise place for the borehole and for next excavation. The results of drilling showed, as it was forecasted, that from the depth 7m on the showed picket of the observed profile it had been revealed stone objects which differ from the limestones sandstones. The drilling was achieved on 20-th of april 2008.

  16. Crustal deformation rates in Assam Valley, Shillong Plateau, Eastern Himalaya, and Indo-Burmese region from 11 years (2002-2013) of GPS measurements

    NASA Astrophysics Data System (ADS)

    Barman, Prakash; Jade, Sridevi; Shrungeshwara, T. S.; Kumar, Ashok; Bhattacharyya, Sanjeev; Ray, Jagat Dwipendra; Jagannathan, Saigeetha; Jamir, Wangshi Menla

    2017-09-01

    The present study reports the contemporary deformation of the tectonically complex northeast India using 11 years (2002-2013) of GPS observations. The central Shillong Plateau and few sites north of Plateau located in Assam Valley behave like a rigid block with 7 mm/year India-fixed southward velocity. The Euler pole of rotation of this central Shillong Plateau-Assam Valley (SH-AS) block is estimated to be at -25.1° ± 0.2°N, -97.8° ± 1.8°E with an angular velocity of 0.533° ± 0.10° Myr-1 relative to India-fixed reference frame. Kopili fault located between Shillong Plateau and Mikir massif records a dextral slip of 4.7 ± 1.3 mm/year with a locking depth of 10.2 ± 1.4 km indicating the fragmentation of Assam Valley across the fault. Presently, western edge of Mikir massif appears to be locked to Assam block indicating strain accumulation in this region. First-order elastic dislocation modelling of the GPS velocities estimates a slip rate of 16 mm/year along the Main Himalayan Thrust in Eastern Himalaya which is locked over a width of 130 km from the surface to a depth of 17 km with underthrusting Indian plate. Around 9 mm/year arc-normal convergence is accommodated in Lesser Himalaya just south of Main Central Thrust indicating high strain accumulation. Out of 36 mm/year (SSE) India-Sunda plate motion, about 16 mm/year motion is accommodated in Indo-Burmese Fold and Thrust Belt, both as normal convergence ( 6 mm/year) and active slip ( 7-11 mm/year) in this region.

  17. Young investigator challenge: Validation and optimization of immunohistochemistry protocols for use on cellient cell block specimens.

    PubMed

    Sauter, Jennifer L; Grogg, Karen L; Vrana, Julie A; Law, Mark E; Halvorson, Jennifer L; Henry, Michael R

    2016-02-01

    The objective of the current study was to establish a process for validating immunohistochemistry (IHC) protocols for use on the Cellient cell block (CCB) system. Thirty antibodies were initially tested on CCBs using IHC protocols previously validated on formalin-fixed, paraffin-embedded tissue (FFPE). Cytology samples were split to generate thrombin cell blocks (TCB) and CCBs. IHC was performed in parallel. Antibody immunoreactivity was scored, and concordance or discordance in immunoreactivity between the TCBs and CCBs for each sample was determined. Criteria for validation of an antibody were defined as concordant staining in expected positive and negative cells, in at least 5 samples each, and concordance in at least 90% of the samples total. Antibodies that failed initial validation were retested after alterations in IHC conditions. Thirteen of the 30 antibodies (43%) did not meet initial validation criteria. Of those, 8 antibodies (calretinin, clusters of differentiation [CD] 3, CD20, CDX2, cytokeratin 20, estrogen receptor, MOC-31, and p16) were optimized for CCBs and subsequently validated. Despite several alterations in conditions, 3 antibodies (Ber-EP4, D2-40, and paired box gene 8 [PAX8]) were not successfully validated. Nearly one-half of the antibodies tested in the current study failed initial validation using IHC conditions that were established in the study laboratory for FFPE material. Although some antibodies subsequently met validation criteria after optimization of conditions, a few continued to demonstrate inadequate immunoreactivity. These findings emphasize the importance of validating IHC protocols for methanol-fixed tissue before clinical use and suggest that optimization for alcohol fixation may be needed to obtain adequate immunoreactivity on CCBs. © 2016 American Cancer Society.

  18. Impact of pectoral nerve block on postoperative pain and quality of recovery in patients undergoing breast cancer surgery: A randomised controlled trial.

    PubMed

    Kamiya, Yoshinori; Hasegawa, Miki; Yoshida, Takayuki; Takamatsu, Misako; Koyama, Yu

    2018-03-01

    In recent years, thoracic wall nerve blocks, such as the pectoral nerve (PECS) block and the serratus plane block have become popular for peri-operative pain control in patients undergoing breast cancer surgery. The effect of PECS block on quality of recovery (QoR) after breast cancer surgery has not been evaluated. To evaluate the ability of PECS block to decrease postoperative pain and anaesthesia and analgesia requirements and to improve postoperative QoR in patients undergoing breast cancer surgery. Randomised controlled study. A tertiary hospital. Sixty women undergoing breast cancer surgery between April 2014 and February 2015. The patients were randomised to receive a PECS block consisting of 30 ml of levobupivacaine 0.25% after induction of anaesthesia (PECS group) or a saline mock block (control group). The patients answered a 40-item QoR questionnaire (QoR-40) before and 1 day after breast cancer surgery. Numeric Rating Scale score for postoperative pain, requirement for intra-operative propofol and remifentanil, and QoR-40 score on postoperative day 1. PECS block combined with propofol-remifentanil anaesthesia significantly improved the median [interquartile range] pain score at 6 h postoperatively (PECS group 1 [0 to 2] vs. Control group 1 [0.25 to 2.75]; P = 0.018]. PECS block also reduced propofol mean (± SD) estimated target blood concentration to maintain bispectral index (BIS) between 40 and 50 (PECS group 2.65 (± 0.52) vs. Control group 3.08 (± 0.41) μg ml; P < 0.001) but not remifentanil consumption (PECS group 10.5 (± 4.28) vs. Control group 10.4 (± 4.68) μg kg h; P = 0.95). PECS block did not improve the QoR-40 score on postoperative day 1 (PECS group 182 [176 to 189] vs. Control group 174.5 [157.75 to 175]). In patients undergoing breast cancer surgery, PECS block combined with general anaesthesia reduced the requirement for propofol but not that for remifentanil, due to the inability of the PECS block to reach the internal mammary area. Further, PECS block improved postoperative pain but not the postoperative QoR-40 score due to the factors that cannot be measured by analgesia immediately after surgery, such as rebound pain. This trial is registered with the University Hospital Medical Information Network Clinical Trials Registry (UMIN000013435).

  19. 75 FR 66295 - Fixed Assets, Member Business Loans, and Regulatory Flexibility Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-28

    ... assets, member business loans (MBL), stress testing of investments, and discretionary control of...) discretionary control of investments; (6) stress testing of investments; (7) zero-coupon securities; (8... fixed assets, MBL, stress testing of investments, and discretionary control of investments provisions of...

  20. Feed withdrawal and transportation effects on Salmonella enterica levels in market-weight pigs.

    PubMed

    Eicher, S D; Rostagno, M H; Lay, D C

    2017-07-01

    Feed withdrawal and transport commonly occur together in pigs. Objectives of this study were to determine if these preslaughter stressors, feed withdrawal and transportation, affect the levels of , stress hormone concentrations, and immune functions in infected market pigs. A 2 × 2 factorial analysis of a randomized complete block design with feed withdrawal and transport as fixed effects was used. Sixty market-weight pigs were individually inoculated with serovar Typhimurium. The experiment was replicated 3 times (blocking factor) with 20 pigs per replicate. Three days after inoculation, the pigs were randomly assigned to 1 of 4 treatments (5 pigs per treatment in each/replicate), including 1) control (Control; or no stress), 2) feed withdrawal for 12 h (FW), 3) transportation for 2 h (T), and 4) feed withdrawal for 12 h followed by transportation for 2 h (FWT). Feed withdrawal by itself or followed by transportation caused an increase of levels in ileal contents ( < 0.05), whereas only FWT caused an increase of levels in cecal contents ( < 0.05). Rectal contents (feces) consistently contained very low levels of , with no difference among treatments ( > 0.10). Cortisol increased in pigs from all 3 stress treatments ( < 0.001), with T and FWT pigs having greater concentrations than Control pigs ( < 0.05), although total white blood cell counts were lower for FWT pigs compared with Controls ( > 0.03). Each granulocyte percentage (neutrophil, eosinophils, and basophils) increased ( < 0.05) following transport but was attenuated ( > 0.05) by feed withdrawal with transport. Lymphocytes were suppressed ( < 0.05) by all stressors, and the greatest suppression occurred when pigs were transported (T and FWT). However, monocytes were suppressed ( < 0.05) compared with Controls only by FWT. Expression of IL-1 (produced by monocytes/macrophages) from the spleen cells increased ( < 0.05) with FW compared with Controls, whereas its receptor antagonist was suppressed by FWT ( < 0.05). It is concluded that some typical preslaughter practices, such as feed withdrawal and transportation, lead to greater intestinal levels and gut-associated lymphoid tissue markers of inflammation in market pigs and, consequently, to an increased food safety risk.

  1. Comprehensive Aeroelastic Analysis of Helicopter Rotor with Trailing-Edge Flap for Primary Control and Vibration Control

    DTIC Science & Technology

    2003-01-01

    183 3.34 5/rev fixed system hub normal force with 4/rev open loop trailing-edge flap input...184 3.35 5/rev fixed system hub normal force with 5/rev open loop trailing-edge flap input...185 3.36 5/rev fixed system hub normal force with 6/rev open loop trailing-edge flap

  2. Mapping the Complex Morphology of Cell Interactions with Nanowire Substrates Using FIB-SEM

    PubMed Central

    Jensen, Mikkel R. B.; Łopacińska, Joanna; Schmidt, Michael S.; Skolimowski, Maciej; Abeille, Fabien; Qvortrup, Klaus; Mølhave, Kristian

    2013-01-01

    Using high resolution focused ion beam scanning electron microscopy (FIB-SEM) we study the details of cell-nanostructure interactions using serial block face imaging. 3T3 Fibroblast cellular monolayers are cultured on flat glass as a control surface and on two types of nanostructured scaffold substrates made from silicon black (Nanograss) with low- and high nanowire density. After culturing for 72 hours the cells were fixed, heavy metal stained, embedded in resin, and processed with FIB-SEM block face imaging without removing the substrate. The sample preparation procedure, image acquisition and image post-processing were specifically optimised for cellular monolayers cultured on nanostructured substrates. Cells display a wide range of interactions with the nanostructures depending on the surface morphology, but also greatly varying from one cell to another on the same substrate, illustrating a wide phenotypic variability. Depending on the substrate and cell, we observe that cells could for instance: break the nanowires and engulf them, flatten the nanowires or simply reside on top of them. Given the complexity of interactions, we have categorised our observations and created an overview map. The results demonstrate that detailed nanoscale resolution images are required to begin understanding the wide variety of individual cells’ interactions with a structured substrate. The map will provide a framework for light microscopy studies of such interactions indicating what modes of interactions must be considered. PMID:23326412

  3. Initial Skill Acquisition of Handrim Wheelchair Propulsion: A New Perspective.

    PubMed

    Vegter, Riemer J K; de Groot, Sonja; Lamoth, Claudine J; Veeger, Dirkjan Hej; van der Woude, Lucas H V

    2014-01-01

    To gain insight into cyclic motor learning processes, hand rim wheelchair propulsion is a suitable cyclic task, to be learned during early rehabilitation and novel to almost every individual. To propel in an energy efficient manner, wheelchair users must learn to control bimanually applied forces onto the rims, preserving both speed and direction of locomotion. The purpose of this study was to evaluate mechanical efficiency and propulsion technique during the initial stage of motor learning. Therefore, 70 naive able-bodied men received 12-min uninstructed wheelchair practice, consisting of three 4-min blocks separated by 2 min rest. Practice was performed on a motor-driven treadmill at a fixed belt speed and constant power output relative to body mass. Energy consumption and the kinetics of propulsion technique were continuously measured. Participants significantly increased their mechanical efficiency and changed their propulsion technique from a high frequency mode with a lot of negative work to a longer-slower movement pattern with less power losses. Furthermore a multi-level model showed propulsion technique to relate to mechanical efficiency. Finally improvers and non-improvers were identified. The non-improving group was already more efficient and had a better propulsion technique in the first block of practice (i.e., the fourth minute). These findings link propulsion technique to mechanical efficiency, support the importance of a correct propulsion technique for wheelchair users and show motor learning differences.

  4. A New Strategy to Prepare Polymer-based Shape Memory Elastomers.

    PubMed

    Song, Shijie; Feng, Jiachun; Wu, Peiyi

    2011-10-04

    A new strategy that utilizes the microphase separation of block copolymer and phase transition of small molecules for preparing polymer-based shape memory elastomer has been proposed. According to this strategy, a novel kind of shape memory elastomer comprising styrene-b-(ethylene-co-butylene)-b-styrene (SEBS) and paraffin has been prepared. Because paraffins are midblock-selective molecules for SEBS, they will preferentially enter and swell EB blocks supporting paraffins as an excellent switch phase for shape memory effect. Microstructures of SEBS/paraffin composites have been characterized by transmission electron microscopy, polarized light microscopy, and differential scanning calorimetry. The composites demonstrate various phase morphologies with regard to different paraffin loading. It has been found that under low paraffin loading, all the paraffins precisely embed in and swell EB-rich domains. While under higher loading, part of the paraffins become free and a larger-scaled phase separation has been observed. However, within wide paraffin loadings, all composites show good shape fixing, shape recovery performances, and improved tensile properties. Compared to the reported methods for shape memory elastomers preparation, this method not only simplifies the fabrication procedure from raw materials to processing but also offers a controllable approach for the optimization of shape memory properties as well as balancing the rigidity and softness of the material. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Mining the archives: a cross-platform analysis of gene ...

    EPA Pesticide Factsheets

    Formalin-fixed paraffin-embedded (FFPE) tissue samples represent a potentially invaluable resource for genomic research into the molecular basis of disease. However, use of FFPE samples in gene expression studies has been limited by technical challenges resulting from degradation of nucleic acids. Here we evaluated gene expression profiles derived from fresh-frozen (FRO) and FFPE mouse liver tissues using two DNA microarray protocols and two whole transcriptome sequencing (RNA-seq) library preparation methodologies. The ribo-depletion protocol outperformed the other three methods by having the highest correlations of differentially expressed genes (DEGs) and best overlap of pathways between FRO and FFPE groups. We next tested the effect of sample time in formalin (18 hours or 3 weeks) on gene expression profiles. Hierarchical clustering of the datasets indicated that test article treatment, and not preservation method, was the main driver of gene expression profiles. Meta- and pathway analyses indicated that biological responses were generally consistent for 18-hour and 3-week FFPE samples compared to FRO samples. However, clear erosion of signal intensity with time in formalin was evident, and DEG numbers differed by platform and preservation method. Lastly, we investigated the effect of age in FFPE block on genomic profiles. RNA-seq analysis of 8-, 19-, and 26-year-old control blocks using the ribo-depletion protocol resulted in comparable quality metrics, inc

  6. The Combined Use of a Gas-Controlled Heat Pipe and a Copper Point to Improve the Calibration of Thermocouples up to 1100 ˚C

    NASA Astrophysics Data System (ADS)

    Astrua, M.; Iacomini, L.; Battuello, M.

    2008-10-01

    The calibration of platinum-based thermocouples from 420 °C to 1,100 ˚C is currently carried out at INRIM making use of two different apparatus: for temperatures below 930 ˚C, a potassium gas-controlled heat pipe (GCHP) is used, whereas a metal-block furnace is adopted for higher temperatures. The standard uncertainty of the reference temperature obtained in the lower temperature range is almost one order of magnitude better than in the higher temperature range. A sealed copper cell was investigated to see if it could be used to calibrate thermocouples above 930 ˚C with a lower uncertainty than our current procedures allowed. The cell was characterized with Type S and Pt/Pd thermocouples and with an HTPRT. The freezing plateaux were flat within 0.01 ˚C and lasted up to 1 h with a repeatability of 0.02 ˚C. The temperature of the cell was determined with a standard uncertainty of 0.04 ˚C. Hence, the copper cell was found to be superior to the comparator furnace for the calibration of platinum-based thermocouples because of the significant decrease in the uncertainty that it provides. An analysis was also carried out on the calibration of Pt/Pd thermocouples, and it was found that the combined use of the potassium GCHP and the Cu fixed-point cell is adequate to exploit the potential of these sensors in the range from 420 °C to 1,084 °C. A comparison with a fixed-point calibration was also made which gave rise to agreement within 0.07 ˚C between the two approaches.

  7. FERMI/GLAST Integrated Trending and Plotting System Release 5.0

    NASA Technical Reports Server (NTRS)

    Ritter, Sheila; Brumer, Haim; Reitan, Denise

    2012-01-01

    An Integrated Trending and Plotting System (ITPS) is a trending, analysis, and plotting system used by space missions to determine performance and status of spacecraft and its instruments. ITPS supports several NASA mission operational control centers providing engineers, ground controllers, and scientists with access to the entire spacecraft telemetry data archive for the life of the mission, and includes a secure Web component for remote access. FERMI/GLAST ITPS Release 5.0 features include the option to display dates (yyyy/ddd) instead of orbit numbers along orbital Long-Term Trend (LTT) plot axis, the ability to save statistics from daily production plots as image files, and removal of redundant edit/create Input Definition File (IDF) screens. Other features are a fix to address invalid packet lengths, a change in naming convention of image files in order to use in script, the ability to save all ITPS plot images (from Windows or the Web) as GIF or PNG format, the ability to specify ymin and ymax on plots where previously only the desired range could be specified, Web interface capability to plot IDFs that contain out-oforder page and plot numbers, and a fix to change all default file names to show yyyydddhhmmss time stamps instead of hhmmssdddyyyy. A Web interface capability sorts files based on modification date (with newest one at top), and the statistics block can be displayed via a Web interface. Via the Web, users can graphically view the volume of telemetry data from each day contained in the ITPS archive in the Web digest. The ITPS could be also used in nonspace fields that need to plot data or trend data, including financial and banking systems, aviation and transportation systems, healthcare and educational systems, sales and marketing, and housing and construction.

  8. Mosquito larvicidal effectiveness of EcoBio-Block S: a novel integrated water-purifying concrete block formulation containing insect growth regulator pyriproxyfen.

    PubMed

    Kawada, Hitoshi; Saita, Susumu; Shimabukuro, Kozue; Hirano, Masachika; Koga, Masayuki; Iwashita, Toshiaki; Takagi, Masahiro

    2006-09-01

    EcoBio-Block S, a novel controlled release system (CRS) for the insect growth regulator pyriproxyfen, uses a water-purifying concrete block system (EcoBio-Block) composed of a porous volcanic rock and cement, and it incorporates the aerobic bacterial groups of Bacillus subtilis natto. EcoBio-Block S showed high inhibitory activity against mosquito emergence as well as a water-purifying effect. Chemical analysis and bioassay showed that EcoBio-Block S provides a high-performance CRS that controls the release of pyriproxyfen at low levels according to "zero order kinetics".

  9. Robust fixed-time synchronization for uncertain complex-valued neural networks with discontinuous activation functions.

    PubMed

    Ding, Xiaoshuai; Cao, Jinde; Alsaedi, Ahmed; Alsaadi, Fuad E; Hayat, Tasawar

    2017-06-01

    This paper is concerned with the fixed-time synchronization for a class of complex-valued neural networks in the presence of discontinuous activation functions and parameter uncertainties. Fixed-time synchronization not only claims that the considered master-slave system realizes synchronization within a finite time segment, but also requires a uniform upper bound for such time intervals for all initial synchronization errors. To accomplish the target of fixed-time synchronization, a novel feedback control procedure is designed for the slave neural networks. By means of the Filippov discontinuity theories and Lyapunov stability theories, some sufficient conditions are established for the selection of control parameters to guarantee synchronization within a fixed time, while an upper bound of the settling time is acquired as well, which allows to be modulated to predefined values independently on initial conditions. Additionally, criteria of modified controller for assurance of fixed-time anti-synchronization are also derived for the same system. An example is included to illustrate the proposed methodologies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Control analysis of lipid biosynthesis in tissue cultures from oil crops shows that flux control is shared between fatty acid synthesis and lipid assembly.

    PubMed Central

    Ramli, Umi S; Baker, Darren S; Quant, Patti A; Harwood, John L

    2002-01-01

    Top-Down (Metabolic) Control Analysis (TDCA) was used to examine, quantitatively, lipid biosynthesis in tissue cultures from two commercially important oil crops, olive (Olea europaea L.) and oil palm (Elaeis guineensis Jacq.). A conceptually simplified system was defined comprising two blocks of reactions: fatty acid synthesis (Block A) and lipid assembly (Block B), which produced and consumed, respectively, a common and unique system intermediate, cytosolic acyl-CoA. We manipulated the steady-state levels of the system intermediate by adding exogenous oleic acid and, using two independent assays, measured the effect of the addition on the system fluxes (J(A) and J(B)). These were the rate of incorporation of radioactivity: (i) through Block A from [1-(14)C]acetate into fatty acids and (ii) via Block B from [U-(14)C]glycerol into complex lipids respectively. The data showed that fatty acid formation (Block A) exerted higher control than lipid assembly (Block B) in both tissues with the following group flux control coefficients (C):(i) Oil palm: *C(J(TL))(BlkA)=0.64+/-0.05 and *C(J(TL))(BlkB)=0.36+/-0.05(ii) Olive: *C(J(TL))(BlkA)=0.57+/-0.10 and *C(J(TL))(BlkB)=0.43+/-0.10where *C indicates the group flux control coefficient over the lipid biosynthesis flux (J(TL)) and the subscripts BlkA and BlkB refer to defined blocks of the system, Block A and Block B. Nevertheless, because both parts of the lipid biosynthetic pathway exert significant flux control, we suggest strongly that manipulation of single enzyme steps will not affect product yield appreciably. The present study represents the first use of TDCA to examine the overall lipid biosynthetic pathway in any tissue, and its findings are of immediate academic and economic relevance to the yield and nutritional quality of oil crops. PMID:12023882

  11. 49 CFR 236.511 - Cab signals controlled in accordance with block conditions stopping distance in advance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Cab signals controlled in accordance with block conditions stopping distance in advance. 236.511 Section 236.511 Transportation Other Regulations Relating to... § 236.511 Cab signals controlled in accordance with block conditions stopping distance in advance. The...

  12. Secure Oblivious Hiding, Authentication, Tamper Proofing, and Verification Techniques

    DTIC Science & Technology

    2002-08-01

    compressing the bit- planes. The algorithm always starts with inspecting the 5th LSB plane. For color images , all three color-channels are compressed...use classical encryption engines, such as IDEA or DES . These algorithms have a fixed encryption block size, and, depending on the image dimensions, we...information can be stored either in a separate file, in the image header, or embedded in the image itself utilizing the modern concepts of steganography

  13. Testing of Error-Correcting Sparse Permutation Channel Codes

    NASA Technical Reports Server (NTRS)

    Shcheglov, Kirill, V.; Orlov, Sergei S.

    2008-01-01

    A computer program performs Monte Carlo direct numerical simulations for testing sparse permutation channel codes, which offer strong error-correction capabilities at high code rates and are considered especially suitable for storage of digital data in holographic and volume memories. A word in a code of this type is characterized by, among other things, a sparseness parameter (M) and a fixed number (K) of 1 or "on" bits in a channel block length of N.

  14. Navy Shipbuilding: Significant Investments in the Littoral Combat Ship Continue Amid Substantial Unknowns about Capabilities, Use, and Cost

    DTIC Science & Technology

    2013-07-01

    composed of vice admirals from the requirements, acquisition, and fleet communities, and has the mission of ensuring “the successful procurement...development, manning, training, sustainment, and operational employment” of the LCS, mission packages, and shore 4The LCS block buy contracts include fixed...capabilities, limitations, and safety issues to help reduce design and programmatic risks. Operational testing is intended to assess a weapon system’s

  15. Virtual reality flight control display with six-degree-of-freedom controller and spherical orientation overlay

    NASA Technical Reports Server (NTRS)

    Beckman, Brian C. (Inventor)

    1995-01-01

    A virtual reality flight control system displays to the pilot the image of a scene surrounding a vehicle or pod having six degrees of freedom of acceleration or velocity control by the pilot and traveling through inertial space, the image itself including a superimposed figure providing the pilot an instant reference of orientation consisting of superimposed sets of geometric figures whose relative orientations provide the pilot an instantaneous feel or sense of orientation changes with respect to some fixed coordinate system. They include a first set of geometric figures whose orientations are fixed to the pilot's vehicle and a second set of geometric figures whose orientations are fixed with respect to a fixed or interstellar coordinate system. The first set of figures is a first set of orthogonal great circles about the three orthogonal axes of the flight vehicle or pod and centered at and surrounding the pilot's head, while the second set of figures is a second set of orthogonal great circles about the three orthogonal axes of a fixed or interstellar coordinate system, also centered at and surrounding the pilot's head.

  16. [Motion control of moving mirror based on fixed-mirror adjustment in FTIR spectrometer].

    PubMed

    Li, Zhong-bing; Xu, Xian-ze; Le, Yi; Xu, Feng-qiu; Li, Jun-wei

    2012-08-01

    The performance of the uniform motion of the moving mirror, which is the only constant motion part in FTIR spectrometer, and the performance of the alignment of the fixed mirror play a key role in FTIR spectrometer, and affect the interference effect and the quality of the spectrogram and may restrict the precision and resolution of the instrument directly. The present article focuses on the research on the uniform motion of the moving mirror and the alignment of the fixed mirror. In order to improve the FTIR spectrometer, the maglev support system was designed for the moving mirror and the phase detection technology was adopted to adjust the tilt angle between the moving mirror and the fixed mirror. This paper also introduces an improved fuzzy PID control algorithm to get the accurate speed of the moving mirror and realize the control strategy from both hardware design and algorithm. The results show that the development of the moving mirror motion control system gets sufficient accuracy and real-time, which can ensure the uniform motion of the moving mirror and the alignment of the fixed mirror.

  17. Design and FPGA Implementation of a Universal Chaotic Signal Generator Based on the Verilog HDL Fixed-Point Algorithm and State Machine Control

    NASA Astrophysics Data System (ADS)

    Qiu, Mo; Yu, Simin; Wen, Yuqiong; Lü, Jinhu; He, Jianbin; Lin, Zhuosheng

    In this paper, a novel design methodology and its FPGA hardware implementation for a universal chaotic signal generator is proposed via the Verilog HDL fixed-point algorithm and state machine control. According to continuous-time or discrete-time chaotic equations, a Verilog HDL fixed-point algorithm and its corresponding digital system are first designed. In the FPGA hardware platform, each operation step of Verilog HDL fixed-point algorithm is then controlled by a state machine. The generality of this method is that, for any given chaotic equation, it can be decomposed into four basic operation procedures, i.e. nonlinear function calculation, iterative sequence operation, iterative values right shifting and ceiling, and chaotic iterative sequences output, each of which corresponds to only a state via state machine control. Compared with the Verilog HDL floating-point algorithm, the Verilog HDL fixed-point algorithm can save the FPGA hardware resources and improve the operation efficiency. FPGA-based hardware experimental results validate the feasibility and reliability of the proposed approach.

  18. Lesson learned from monitoring the environmental effects of construction of the first offshore wind farm in the US

    NASA Astrophysics Data System (ADS)

    Miller, J.; Potty, G. R.; King, J. W.; Gallien, D. R.; Khan, A. A.; Vigness Raposa, K.; Giard, J. L.; Frankel, A. S.; Mason, T.; Popper, A. N.; Hawkins, A. D.; Crocker, S. E.

    2016-02-01

    Noise radiation from pile driving activities were monitored using multiple sensors during the construction of the USA's first offshore wind farm located 3 nm off Block Island, RI. The 30-megawatt Block Island Wind Farm (BIWF) consists of five turbines in water depths of approximately 30 m and is scheduled to be online in 2016. The substructure for these turbines consists of jacket type construction with piles driven to pin the structure to the seabed. Pile driving operations generate intense sound, impulsive in nature at close range, which radiates into the surrounding air, water and sediment. The underwater acoustic measurement platforms consisted of a towed array consisting of eight hydrophones, two fixed moorings with four hydrophones each, a fixed sensor package for measuring particle velocity, and boat-deployed dipping hydrophones. The hydrophone array was towed from a position 1 km from the pile driving location to 15 km distance from the construction. The fixed moorings were deployed at 10 km and 15 km from the pile location. The fixed moorings consisted of four hydrophones each at depths of 10, 15, 20 and 25 m. Near field measurements of the underwater acoustic signals from the pile driving were collected with a tetrahedral array deployed at 500 m from the pile driving location about 1 m above the seabed. The boat-deployed dipping hydrophones sampled the acoustic field at locations from 0.5 km to 20 km from the pile driving locations. Based on these acoustic measurements and propagation modeling, the acoustic pressure field as a function of range and depth from the pile is estimated. The transition from fast-rise-time impulsive signals at close range to slow-rise-time non-impulsive signals at longer ranges will be addressed. This study will provide the required information to qualify the different zones of potential marine mammal effects (zones of injury, behavioral effects etc.) and to estimate exposure to fishes and other species. [Work supported by Bureau of Ocean Energy Management (BOEM)

  19. Meet-in-the-Middle Preimage Attacks on Hash Modes of Generalized Feistel and Misty Schemes with SP Round Function

    NASA Astrophysics Data System (ADS)

    Moon, Dukjae; Hong, Deukjo; Kwon, Daesung; Hong, Seokhie

    We assume that the domain extender is the Merkle-Damgård (MD) scheme and he message is padded by a ‘1’, and minimum number of ‘0’s, followed by a fixed size length information so that the length of padded message is multiple of block length. Under this assumption, we analyze securities of the hash mode when the compression function follows the Davies-Meyer (DM) scheme and the underlying block cipher is one of the plain Feistel or Misty scheme or the generalized Feistel or Misty schemes with Substitution-Permutation (SP) round function. We do this work based on Meet-in-the-Middle (MitM) preimage attack techniques, and develop several useful initial structures.

  20. Measuring strategic control in artificial grammar learning.

    PubMed

    Norman, Elisabeth; Price, Mark C; Jones, Emma

    2011-12-01

    In response to concerns with existing procedures for measuring strategic control over implicit knowledge in artificial grammar learning (AGL), we introduce a more stringent measurement procedure. After two separate training blocks which each consisted of letter strings derived from a different grammar, participants either judged the grammaticality of novel letter strings with respect to only one of these two grammars (pure-block condition), or had the target grammar varying randomly from trial to trial (novel mixed-block condition) which required a higher degree of conscious flexible control. Random variation in the colour and font of letters was introduced to disguise the nature of the rule and reduce explicit learning. Strategic control was observed both in the pure-block and mixed-block conditions, and even among participants who did not realise the rule was based on letter identity. This indicated detailed strategic control in the absence of explicit learning. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Effect of social media in improving knowledge among patients having fixed appliance orthodontic treatment: A single-center randomized controlled trial.

    PubMed

    Al-Silwadi, Fadi M; Gill, Daljit S; Petrie, Aviva; Cunningham, Susan J

    2015-08-01

    Research has shown that orthodontic patients are more likely to retain information presented in an audiovisual format. However, there has been little research on the effectiveness of audiovisual information provided through different routes such as the Internet. This parallel-group randomized controlled trial assessed whether provision of audiovisual information on the YouTube (Google, San Bruno, Calif) Web site to orthodontic patients undergoing fixed appliance treatment results in improved patient knowledge when compared with conventional methods of information provision. The effects of sex and ethnicity were also investigated. Participants were recruited from the Department of Orthodontics of the Eastman Dental Hospital, University College London Hospitals NHS Foundation Trust, United Kingdom. The patients were 13 years of age and over, with no history of orthodontic treatment, and patient and parental (where appropriate) consent were obtained. The participants were randomized into control (n = 34) and intervention (n = 33) groups using a random number table; there was stratification based on age group, with permuted blocks of 10 patients. Both groups were given routine verbal and written patient information related to fixed appliances, and the participants in the intervention group were sent 3 e-mails over 6 weeks requesting that they view a 6-minute YouTube video containing similar information but in audiovisual format. Patient knowledge was measured using identical questionnaires answered on the day of recruitment (baseline) and again 6 to 8 weeks later. The researchers were unaware of group allocations when enrolling patients and scoring questionnaires. Sixty participants (89.55%) completed the study. Those who completed the trial in the intervention group (n = 30) demonstrated significantly greater improvements in knowledge than did those in the control group (n = 30), scoring, on average, almost 1 point more (95% CI for the difference, 0.305-1.602; P = 0.005) on the final questionnaire. Ethnicity had a statistically significant effect on improvement in knowledge, but sex did not. No harm to any patient was noted during the trial. Presenting audiovisual information through the YouTube Web site to orthodontic patients resulted in a significant improvement in patient knowledge. Supplementation of verbal and written patient information with audiovisual information via the Internet is therefore worthy of consideration. National Research and Ethics Service (REC number 12/LO/0863), United Kingdom. The protocol was not published before trial commencement. No funding or conflict of interest to be declared. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  2. A VLSI decomposition of the deBruijn graph

    NASA Technical Reports Server (NTRS)

    Collins, O.; Dolinar, S.; Mceliece, R.; Pollara, F.

    1990-01-01

    A new Viterbi decoder for convolutional codes with constraint lengths up to 15, called the Big Viterbi Decoder, is under development for the Deep Space Network. It will be demonstrated by decoding data from the Galileo spacecraft, which has a rate 1/4, constraint-length 15 convolutional encoder on board. Here, the mathematical theory underlying the design of the very-large-scale-integrated (VLSI) chips that are being used to build this decoder is explained. The deBruijn graph B sub n describes the topology of a fully parallel, rate 1/v, constraint length n+2 Viterbi decoder, and it is shown that B sub n can be built by appropriately wiring together (i.e., connecting together with extra edges) many isomorphic copies of a fixed graph called a B sub n building block. The efficiency of such a building block is defined as the fraction of the edges in B sub n that are present in the copies of the building block. It is shown, among other things, that for any alpha less than 1, there exists a graph G which is a B sub n building block of efficiency greater than alpha for all sufficiently large n. These results are illustrated by describing a special hierarchical family of deBruijn building blocks, which has led to the design of the gate-array chips being used in the Big Viterbi Decoder.

  3. Optimal Hydrophobicity in Ring-Opening Metathesis Polymerization-Based Protein Mimics Required for siRNA Internalization.

    PubMed

    deRonde, Brittany M; Posey, Nicholas D; Otter, Ronja; Caffrey, Leah M; Minter, Lisa M; Tew, Gregory N

    2016-06-13

    Exploring the role of polymer structure for the internalization of biologically relevant cargo, specifically siRNA, is of critical importance to the development of improved delivery reagents. Herein, we report guanidinium-rich protein transduction domain mimics (PTDMs) based on a ring-opening metathesis polymerization scaffold containing tunable hydrophobic moieties that promote siRNA internalization. Structure-activity relationships using Jurkat T cells and HeLa cells were explored to determine how the length of the hydrophobic block and the hydrophobic side chain compositions of these PTDMs impacted siRNA internalization. To explore the hydrophobic block length, two different series of diblock copolymers were synthesized: one series with symmetric block lengths and one with asymmetric block lengths. At similar cationic block lengths, asymmetric and symmetric PTDMs promoted siRNA internalization in the same percentages of the cell population regardless of the hydrophobic block length; however, with 20 repeat units of cationic charge, the asymmetric block length had greater siRNA internalization, highlighting the nontrivial relationships between hydrophobicity and overall cationic charge. To further probe how the hydrophobic side chains impacted siRNA internalization, an additional series of asymmetric PTDMs was synthesized that featured a fixed hydrophobic block length of five repeat units that contained either dimethyl (dMe), methyl phenyl (MePh), or diphenyl (dPh) side chains and varied cationic block lengths. This series was further expanded to incorporate hydrophobic blocks consisting of diethyl (dEt), diisobutyl (diBu), and dicyclohexyl (dCy) based repeat units to better define the hydrophobic window for which our PTDMs had optimal activity. High-performance liquid chromatography retention times quantified the relative hydrophobicities of the noncationic building blocks. PTDMs containing the MePh, diBu, and dPh hydrophobic blocks were shown to have superior siRNA internalization capabilities compared to their more and less hydrophobic counterparts, demonstrating a critical window of relative hydrophobicity for optimal internalization. This better understanding of how hydrophobicity impacts PTDM-induced internalization efficiencies will help guide the development of future delivery reagents.

  4. Efficacy and safety of nebivolol and valsartan as fixed-dose combination in hypertension: a randomised, multicentre study.

    PubMed

    Giles, Thomas D; Weber, Michael A; Basile, Jan; Gradman, Alan H; Bharucha, David B; Chen, Wei; Pattathil, Manoj

    2014-05-31

    The fixed-dose combination of any two antihypertensive drugs from different drug classes is typically more effective in reducing blood pressure than a dose increase of component monotherapy. We assessed the efficacy and safety of a fixed-dose combination of a vasodilating β blocker (nebivolol) and an angiotensin II receptor blocker (valsartan) in adults with hypertension. We did an 8-week, phase 3, multicentre, randomised, double-blind, placebo-controlled, parallel-group trial at 401 US sites. Participants (age ≥18 years) with hypertension but with blood pressure less than 180/110 mm Hg were randomly assigned (2:2:2:2:2:2:2:1) by a 24-h interactive web response system in blocks of 15 to 4 weeks of double-blind treatment with nebivolol and valsartan fixed-dose combination (5 and 80 mg/day, 5 and 160 mg/day, or 10 and 160 mg/day), nebivolol (5 mg/day or 20 mg/day), valsartan (80 mg/day or 160 mg/day), or placebo. Doses were doubled in weeks 5-8; results are reported according to the final dose. Participants and research staff were masked to treatment allocation. The primary and key secondary endpoints were changes from baseline to week 8 in diastolic and systolic blood pressure, respectively. The primary statistical comparison was between the highest fixed-dose combination dose and the highest monotherapy doses; lower doses were then compared if this comparison was positive (Hochberg method for multiple testing). Efficacy analyses were by intention to treat. Safety assessments included monitoring of adverse events. Continuous efficacy parameters were analysed using an ANCOVA model; binary outcomes were analysed using a logistic regression model. This study is registered with ClinicalTrials.gov, NCT01508026. Between Jan 6, 2012, and March 15, 2013, 4161 patients were randomly assigned (277 to placebo and 554-555 to each active comparator group), 4118 of whom were included in the primary analysis. At week 8, the fixed-dose combination 20 and 320 mg/day group had significantly greater reductions in diastolic blood pressure from baseline than both nebivolol 40 mg/day (least-squares mean difference -1·2 mm Hg, 95% CI -2·3 to -0·1; p=0·030) and valsartan 320 mg/day (-4·4 mm Hg, -5·4 to -3·3; p<0·0001); all other comparisons were also significant, favouring the fixed-dose combinations (all p<0·0001). All systolic blood pressure comparisons were also significant (all p<0·01). At least one treatment-emergent adverse event was experienced by 30-36% of participants in each group. Nebivolol and valsartan fixed-dose combination is an effective and well-tolerated treatment option for patients with hypertension. Forest Research Institute. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Protein based Block Copolymers

    PubMed Central

    Rabotyagova, Olena S.; Cebe, Peggy; Kaplan, David L.

    2011-01-01

    Advances in genetic engineering have led to the synthesis of protein-based block copolymers with control of chemistry and molecular weight, resulting in unique physical and biological properties. The benefits from incorporating peptide blocks into copolymer designs arise from the fundamental properties of proteins to adopt ordered conformations and to undergo self-assembly, providing control over structure formation at various length scales when compared to conventional block copolymers. This review covers the synthesis, structure, assembly, properties, and applications of protein-based block copolymers. PMID:21235251

  6. Integration of sensory force feedback is disturbed in CRPS-related dystonia.

    PubMed

    Mugge, Winfred; van der Helm, Frans C T; Schouten, Alfred C

    2013-01-01

    Complex regional pain syndrome (CRPS) is characterized by pain and disturbed blood flow, temperature regulation and motor control. Approximately 25% of cases develop fixed dystonia. The origin of this movement disorder is poorly understood, although recent insights suggest involvement of disturbed force feedback. Assessment of sensorimotor integration may provide insight into the pathophysiology of fixed dystonia. Sensory weighting is the process of integrating and weighting sensory feedback channels in the central nervous system to improve the state estimate. It was hypothesized that patients with CRPS-related dystonia bias sensory weighting of force and position toward position due to the unreliability of force feedback. The current study provides experimental evidence for dysfunctional sensory integration in fixed dystonia, showing that CRPS-patients with fixed dystonia weight force and position feedback differently than controls do. The study shows reduced force feedback weights in CRPS-patients with fixed dystonia, making it the first to demonstrate disturbed integration of force feedback in fixed dystonia, an important step towards understanding the pathophysiology of fixed dystonia.

  7. Fixed-ratio discrimination: effects of response-produced blackouts1

    PubMed Central

    Lydersen, Tore; Crossman, E. K.

    1974-01-01

    For three pigeons, reinforcement depended upon a left side-key response after execution of a fixed ratio 10 on the center key, and upon a right side-key response after fixed ratio 20. Each response during the fixed ratios produced a 0.5-sec blackout. The time between the first and last response in fixed ratio 10 was then equated with the time between the first and last response in fixed ratio 20 by increasing the blackout duration. The accuracy of side-key choice was disrupted, thereby suggesting that time, rather than number of responses, controlled choice responding. When the time between the first and last response was equated during both ratios, asymptotic accuracy was approximately equal to (two birds) or somewhat higher than (one bird) that obtained previously. The results of probes with intermediate fixed ratios and blackouts suggested that control of side-key choice had transferred from the time between the first and last response in ratios to blackout duration. PMID:16811819

  8. Evaluation of Invisalign treatment effectiveness and efficiency compared with conventional fixed appliances using the Peer Assessment Rating index.

    PubMed

    Gu, Jiafeng; Tang, Jack Shengyu; Skulski, Brennan; Fields, Henry W; Beck, F Michael; Firestone, Allen R; Kim, Do-Gyoon; Deguchi, Toru

    2017-02-01

    The purpose of this retrospective case-control study was to compare the treatment effectiveness and efficiency of the Invisalign system with conventional fixed appliances in treating orthodontic patients with mild to moderate malocclusion in a graduate orthodontic clinic. Using the peer assessment rating (PAR) index, we evaluated pretreatment and posttreatment records of 48 Invisalign patients and 48 fixed appliances patients. The 2 groups of patients were controlled for general characteristics and initial severity of malocclusion. We analyzed treatment outcome, duration, and improvement between the Invisalign and fixed appliances groups. The average pretreatment PAR scores (United Kingdom weighting) were 20.81 for Invisalign and 22.79 for fixed appliances (P = 1.0000). Posttreatment weighted PAR scores between Invisalign and fixed appliances were not statistically different (P = 0.7420). On average, the Invisalign patients finished 5.7 months faster than did those with fixed appliances (P = 0.0040). The weighted PAR score reduction with treatment was not statistically different between the Invisalign and fixed appliances groups (P = 0.4573). All patients in both groups had more than a 30% reduction in the PAR scores. Logistic regression analysis indicated that the odds of achieving "great improvement" in the Invisalign group were 0.329 times the odds of achieving "great improvement" in the fixed appliances group after controlling for age (P = 0.0150). Our data showed that both Invisalign and fixed appliances were able to improve the malocclusion. Invisalign patients finished treatment faster than did those with fixed appliances. However, it appears that Invisalign may not be as effective as fixed appliances in achieving "great improvement" in a malocclusion. This study might help clinicians to determine appropriate patients for Invisalign treatment. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  9. A time-domain decomposition iterative method for the solution of distributed linear quadratic optimal control problems

    NASA Astrophysics Data System (ADS)

    Heinkenschloss, Matthias

    2005-01-01

    We study a class of time-domain decomposition-based methods for the numerical solution of large-scale linear quadratic optimal control problems. Our methods are based on a multiple shooting reformulation of the linear quadratic optimal control problem as a discrete-time optimal control (DTOC) problem. The optimality conditions for this DTOC problem lead to a linear block tridiagonal system. The diagonal blocks are invertible and are related to the original linear quadratic optimal control problem restricted to smaller time-subintervals. This motivates the application of block Gauss-Seidel (GS)-type methods for the solution of the block tridiagonal systems. Numerical experiments show that the spectral radii of the block GS iteration matrices are larger than one for typical applications, but that the eigenvalues of the iteration matrices decay to zero fast. Hence, while the GS method is not expected to convergence for typical applications, it can be effective as a preconditioner for Krylov-subspace methods. This is confirmed by our numerical tests.A byproduct of this research is the insight that certain instantaneous control techniques can be viewed as the application of one step of the forward block GS method applied to the DTOC optimality system.

  10. Cocaine hydrolase encoded in viral vector blocks the reinstatement of cocaine seeking in rats for 6 months

    PubMed Central

    Anker, Justin J.; Brimijoin, Stephen; Gao, Yang; Geng, Liyi; Zlebnik, Natalie E.; Parks, Robin J.; Carroll, Marilyn E.

    2011-01-01

    Background Cocaine dependence is a pervasive disorder with high rates of relapse. In a previous study, direct administration of a quadruple mutant albumin-fused butyrylcholinesterase (BChE) that efficiently catalyzes hydrolysis of cocaine to benzoic acid and ecgonine methyl ester acutely blocked cocaine seeking in an animal model of relapse. In the present experiments these results were extended to achieve a long duration blockade of cocaine seeking with a gene transfer paradigm using a related BChE-based cocaine hydrolase, termed “CocH”. Methods Male and female rats were allowed to self-administer cocaine under a fixed-ratio 1 schedule of reinforcement for approximately 14 days. Following the final self-administration session, rats were injected with CocH vector or a control injection (empty vector or saline), and their cocaine solutions were replaced with saline for 14 days to allow for extinction of lever pressing. Subsequently, they were tested for drug-primed reinstatement by administering i.p. injections of saline (S), cocaine (5, 10, and 15 mg/kg, C), and d-amphetamine (A) according to the following sequence: S, C, S, C, S, C, S, A. Rats then received cocaine-priming injections once weekly for 4 weeks, and subsequently, once monthly for up to 6 months. Results Administration of CocH vector produced substantial and sustained CocH activity in plasma that corresponded with diminished cocaine- (but not amphetamine-) induced reinstatement responding for up to 6 months following treatment (compared to high responding controls). Conclusion These results demonstrate that viral transfer of CocH may be useful in promoting long-term resistance to relapse to cocaine addiction. PMID:22209637

  11. Interactions between moist heating and dynamics in atmospheric predictability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Straus, D.M.; Huntley, M.A.

    1994-02-01

    The predictability properties of a fixed heating version of a GCM in which the moist heating is specified beforehand are studied in a series of identical twin experiments. Comparison is made to an identical set of experiments using the control GCM, a five-level R30 version of the COLA GCM. The experiments each contain six ensembles, with a single ensemble consisting of six 30-day integrations starting from slightly perturbed Northern Hemisphere wintertime initial conditions. The moist heating from each integration within a single control ensemble was averaged over the ensemble. This averaged heating (a function of three spatial dimensions and time)more » was used as the prespecified heating in each member of the corresponding fixed heating ensemble. The errors grow less rapidly in the fixed heating case. The most rapidly growing scales at small times (global wavenumber 6) have doubling times of 3.2 days compared to 2.4 days for the control experiments. The predictability times for the most energetic scales (global wavenumbers 9-12) are about two weeks for the fixed heating experiments, compared to 9 days for the control. The ratio of error energy in the fixed heating to the control case falls below 0.5 by day 8, and then gradually increases as the error growth slows in the control case. The growth of errors is described in terms of budgets of error kinetic energy (EKE) and error available potential energy (EAPE) developed in terms of global wavenumber n. The diabatic generation of EAPE (G[sub APE]) is positive in the control case and is dominated by midlatitude heating errors after day 2. The fixed heating G[sub APE] is negative at all times due to longwave radiative cooling. 36 refs., 9 figs., 1 tab.« less

  12. Ultrasound-guided Combined Fascial Plane Blocks as an Intervention for Pain Management after Laparoscopic Cholecystectomy: A Randomized Control Study

    PubMed Central

    Ramkiran, Seshadri; Jacob, Mathews; Honwad, Manish; Vivekanand, Desiraju; Krishnakumar, Mathangi; Patrikar, Seema

    2018-01-01

    Background: Pain associated with laparoscopic cholecystectomy is most severe during the first 24 h and the port sites are the most painful. Recent multimodal approaches target incisional pain instead of visceral pain which has led to the emergence of abdominal fascial plane blocks. This study embraces a novel combination of two independently effective fascial plane blocks, namely rectus sheath block and subcostal transversus abdominis plane (TAP) block to alleviate postoperative pain. Study Objective: The aim is to evaluate the effectiveness of the combination of rectus sheath block and subcostal TAP block, to compare its efficacy with that of subcostal TAP block alone and with conventional port site infiltration (PSI) in alleviating postoperative pain in patients undergoing laparoscopic cholecystectomy. Methodology: This prospective, randomized control, pilot study included 61 patients scheduled for elective laparoscopic cholecystectomy and distributed among three groups, namely Group 1: Combined subcostal TAP block with rectus sheath block (n = 20); Group 2: Oblique subcostal TAP block alone (n = 21); and Group 3: PSI group as an active control (n = 20). Results: Combined group had significantly lower pain scores, higher satisfaction scores, and reduced rescue analgesia both in early and late postoperative periods than the conventional PSI group. Conclusion: Ultrasound-guided combined fascial plane blocks is a novel intervention in pain management of patients undergoing laparoscopic cholecystectomy and should become the standard of care. PMID:29628547

  13. Real-Time Feedback Control of Flow-Induced Cavity Tones. Part 2; Adaptive Control

    NASA Technical Reports Server (NTRS)

    Kegerise, M. A.; Cabell, R. H.; Cattafesta, L. N., III

    2006-01-01

    An adaptive generalized predictive control (GPC) algorithm was formulated and applied to the cavity flow-tone problem. The algorithm employs gradient descent to update the GPC coefficients at each time step. Past input-output data and an estimate of the open-loop pulse response sequence are all that is needed to implement the algorithm for application at fixed Mach numbers. Transient measurements made during controller adaptation revealed that the controller coefficients converged to a steady state in the mean, and this implies that adaptation can be turned off at some point with no degradation in control performance. When converged, the control algorithm demonstrated multiple Rossiter mode suppression at fixed Mach numbers ranging from 0.275 to 0.38. However, as in the case of fixed-gain GPC, the adaptive GPC performance was limited by spillover in sidebands around the suppressed Rossiter modes. The algorithm was also able to maintain suppression of multiple cavity tones as the freestream Mach number was varied over a modest range (0.275 to 0.29). Beyond this range, stable operation of the control algorithm was not possible due to the fixed plant model in the algorithm.

  14. Control of the Flow Properties of DNA by Topoisomerase II and Its Targeting Inhibitor

    PubMed Central

    Kundukad, Binu; van der Maarel, Johan R.C.

    2010-01-01

    The flow properties of DNA are important for understanding cell division and, indirectly, cancer therapy. DNA topology controlling enzymes such as topoisomerase II are thought to play an essential role. We report experiments showing how double-strand passage facilitated by topoisomerase II controls DNA rheology. For this purpose, we have measured the elastic storage and viscous loss moduli of a model system comprising bacteriophage λ-DNA and human topoisomerase IIα using video tracking of the Brownian motion of colloidal probe particles. We found that the rheology is critically dependent on the formation of temporal entanglements among the DNA molecules with a relaxation time of ∼1 s. We observed that topoisomerase II effectively removes these entanglements and transforms the solution from an elastic physical gel to a viscous fluid depending on the consumption of ATP. A second aspect of this study is the effect of the generic topoisomerase II inhibitor adenylyl-imidodiphosphate (AMP-PNP). In mixtures of AMP-PNP and ATP, the double-strand passage reaction gets blocked and progressively fewer entanglements are relaxed. A total replacement of ATP by AMP-PNP results in a temporal increase in elasticity at higher frequencies, but no transition to an elastic gel with fixed cross-links. PMID:20858436

  15. On the Control of the Fixed Charge Densities in Al2O3-Based Silicon Surface Passivation Schemes.

    PubMed

    Simon, Daniel K; Jordan, Paul M; Mikolajick, Thomas; Dirnstorfer, Ingo

    2015-12-30

    A controlled field-effect passivation by a well-defined density of fixed charges is crucial for modern solar cell surface passivation schemes. Al2O3 nanolayers grown by atomic layer deposition contain negative fixed charges. Electrical measurements on slant-etched layers reveal that these charges are located within a 1 nm distance to the interface with the Si substrate. When inserting additional interface layers, the fixed charge density can be continuously adjusted from 3.5 × 10(12) cm(-2) (negative polarity) to 0.0 and up to 4.0 × 10(12) cm(-2) (positive polarity). A HfO2 interface layer of one or more monolayers reduces the negative fixed charges in Al2O3 to zero. The role of HfO2 is described as an inert spacer controlling the distance between Al2O3 and the Si substrate. It is suggested that this spacer alters the nonstoichiometric initial Al2O3 growth regime, which is responsible for the charge formation. On the basis of this charge-free HfO2/Al2O3 stack, negative or positive fixed charges can be formed by introducing additional thin Al2O3 or SiO2 layers between the Si substrate and this HfO2/Al2O3 capping layer. All stacks provide very good passivation of the silicon surface. The measured effective carrier lifetimes are between 1 and 30 ms. This charge control in Al2O3 nanolayers allows the construction of zero-fixed-charge passivation layers as well as layers with tailored fixed charge densities for future solar cell concepts and other field-effect based devices.

  16. Omission P3 after voluntary action indexes the formation of action-driven prediction.

    PubMed

    Kimura, Motohiro; Takeda, Yuji

    2018-02-01

    When humans frequently experience a certain sensory effect after a certain action, a bidirectional association between neural representations of the action and the sensory effect is rapidly acquired, which enables action-driven prediction of the sensory effect. The present study aimed to test whether or not omission P3, an event-related brain potential (ERP) elicited by the sudden omission of a sensory effect, is sensitive to the formation of action-driven prediction. For this purpose, we examined how omission P3 is affected by the number of possible visual effects. In four separate blocks (1-, 2-, 4-, and 8-stimulus blocks), participants successively pressed a right button at an interval of about 1s. In all blocks, each button press triggered a bar on a display (a bar with square edges, 85%; a bar with round edges, 5%), but occasionally did not (sudden omission of a visual effect, 10%). Participants were required to press a left button when a bar with round edges appeared. In the 1-stimulus block, the orientation of the bar was fixed throughout the block; in the 2-, 4-, and 8-stimulus blocks, the orientation was randomly varied among two, four, and eight possibilities, respectively. Omission P3 in the 1-stimulus block was greater than those in the 2-, 4-, and 8-stimulus blocks; there were no significant differences among the 2-, 4-, and 8-stimulus blocks. This binary pattern nicely fits the limitation in the acquisition of action-effect association; although an association between an action and one visual effect is easily acquired, associations between an action and two or more visual effects cannot be acquired concurrently. Taken together, the present results suggest that omission P3 is highly sensitive to the formation of action-driven prediction. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Stepping motor controller

    DOEpatents

    Bourret, S.C.; Swansen, J.E.

    1982-07-02

    A stepping motor is microprocessor controlled by digital circuitry which monitors the output of a shaft encoder adjustably secured to the stepping motor and generates a subsequent stepping pulse only after the preceding step has occurred and a fixed delay has expired. The fixed delay is variable on a real-time basis to provide for smooth and controlled deceleration.

  18. Fixed-interval performance and self-control in infants.

    PubMed Central

    Darcheville, J C; Rivière, V; Wearden, J H

    1993-01-01

    Twenty-six infants, 3 to 23 months old, were trained on fixed-interval schedules ranging from 10 s to 80 s. The operant response was touching an illuminated location on a touch-sensitive screen, and 20 s of cartoon presentation was the reinforcer. The subjects were also trained in a six-phase self-control procedure in which the critical phases involved choice between 20 s of cartoon available after a 0.5-s delay (impulsive choice) and 40 s of cartoon delayed for 40 s (self-controlled choice). All the youngest children (3 to 5 months) showed long postreinforcement pauses on the fixed-interval schedule, with most intervals involving the emission of a single, reinforced, response, and all made self-controlled choices. Older subjects (9 to 23 months) either produced the same pattern as the younger ones on the fixed-interval schedule (classified as pause-sensitive subjects) or produced short pauses and higher steady response rates (classified as pause-insensitive subjects). All pause-sensitive subjects made self-controlled choices in the self-control condition, and all pause-insensitive subjects made impulsive ones. PMID:8409821

  19. Comparison of Transcutaneous Electrical Nerve Stimulation and Parasternal Block for Postoperative Pain Management after Cardiac Surgery

    PubMed Central

    Ozturk, Nilgun Kavrut; Baki, Elif Dogan; Kavakli, Ali Sait; Sahin, Ayca Sultan; Ayoglu, Raif Umut; Karaveli, Arzu; Emmiler, Mustafa; Inanoglu, Kerem; Karsli, Bilge

    2016-01-01

    Background. Parasternal block and transcutaneous electrical nerve stimulation (TENS) have been demonstrated to produce effective analgesia and reduce postoperative opioid requirements in patients undergoing cardiac surgery. Objectives. To compare the effectiveness of TENS and parasternal block on early postoperative pain after cardiac surgery. Methods. One hundred twenty patients undergoing cardiac surgery were enrolled in the present randomized, controlled prospective study. Patients were assigned to three treatment groups: parasternal block, intermittent TENS application, or a control group. Results. Pain scores recorded 4 h, 5 h, 6 h, 7 h, and 8 h postoperatively were lower in the parasternal block group than in the TENS and control groups. Total morphine consumption was also lower in the parasternal block group than in the TENS and control groups. It was also significantly lower in the TENS group than in the control group. There were no statistical differences among the groups regarding the extubation time, rescue analgesic medication, length of intensive care unit stay, or length of hospital stay. Conclusions. Parasternal block was more effective than TENS in the management of early postoperative pain and the reduction of opioid requirements in patients who underwent cardiac surgery through median sternotomy. This trial is registered with Clinicaltrials.gov number NCT02725229. PMID:27445610

  20. Connected components of irreducible maps and 1D quantum phases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Szehr, Oleg, E-mail: oleg.szehr@posteo.de; Wolf, Michael M., E-mail: wolf@ma.tum.de

    We investigate elementary topological properties of sets of completely positive (CP) maps that arise in quantum Perron-Frobenius theory. We prove that the set of primitive CP maps of fixed Kraus rank is path-connected and we provide a complete classification of the connected components of irreducible CP maps at given Kraus rank and fixed peripheral spectrum in terms of a multiplicity index. These findings are then applied to analyse 1D quantum phases by studying equivalence classes of translational invariant matrix product states that correspond to the connected components of the respective CP maps. Our results extend the previously obtained picture inmore » that they do not require blocking of physical sites, they lead to analytic paths, and they allow us to decompose into ergodic components and to study the breaking of translational symmetry.« less

  1. Existence of solutions of a two-dimensional boundary value problem for a system of nonlinear equations arising in growing cell populations.

    PubMed

    Jeribi, Aref; Krichen, Bilel; Mefteh, Bilel

    2013-01-01

    In the paper [A. Ben Amar, A. Jeribi, and B. Krichen, Fixed point theorems for block operator matrix and an application to a structured problem under boundary conditions of Rotenberg's model type, to appear in Math. Slovaca. (2014)], the existence of solutions of the two-dimensional boundary value problem (1) and (2) was discussed in the product Banach space L(p)×L(p) for p∈(1, ∞). Due to the lack of compactness on L1 spaces, the analysis did not cover the case p=1. The purpose of this work is to extend the results of Ben Amar et al. to the case p=1 by establishing new variants of fixed-point theorems for a 2×2 operator matrix, involving weakly compact operators.

  2. Flight Dynamics Simulation Modeling and Control of a Large Flexible Tiltrotor Aircraft

    DTIC Science & Technology

    2014-09-01

    matrix from fixed to rotating coordinate systems u longitudinal aircraft velocity, state-space control vector v elastic beam chordwise displacement /lateral...spectrum active control , including flight control systems, rotor load limiting, and vibration and noisetiltion [1]. The development of a high-order...the flutter response of fixed- wing aircraft. The B-52 CCV ( Controls Configured Vehicle) was one of the first aircraft to demonstrate benefits of active

  3. Detection of EGFR and KRAS mutations in fine-needle aspirates stored on Whatman FTA cards: is this the tool for biobanking cytological samples in the molecular era?

    PubMed

    da Cunha Santos, Gilda; Liu, Ni; Tsao, Ming-Sound; Kamel-Reid, Suzanne; Chin, Kayu; Geddie, William R

    2010-12-25

    The aims of this study were to compare the quality of DNA recovered from fine-needle aspirates (FNAs) stored on Whatman FTA cards with that retrieved from corresponding cell blocks and to determine whether the DNA extracted from the cards is suitable for multiple mutation analyses. FNAs collected from 18 resected lung tumors and cell suspensions from 4 lung cancer cell lines were placed on FTA Indicating Micro Cards and further processed to produce paired formalin-fixed paraffin-embedded (FFPE) cell blocks. Fragment analysis was used for the detection of EGFR exon 19 deletion, and direct sequencing for detection of EGFR exon 21 L858R mutation and exon 2 deletion of KRAS. Corresponding FFPE tissue sections from 2 resection specimens were also tested. Analyses were successful with all FNAs and lung cancer-derived cell lines collected on cards. Polymerase chain reaction failed in 2 cell blocks. For FNAs collected on cards, 5 cases showed EGFR and 3 showed KRAS mutations. Eleven cases were wild type. With cell blocks, 4 cases were found to harbor KRAS and 4 harbored EGFR mutations. All lung cancer-derived cell lines tested positive for their respective mutations, and there was complete agreement between card and cell block FNA samples for EGFR exon 21. For EGFR exon 19, 1 of 18 cases showed discordant results between the card and cell block, and for KRAS 1 of 17. The two resection specimens tested gave concordant results with the FTA card. Storage of cytologic material on FTA cards can maximize and simplify sample procurement for multiple mutational analyses with results similar to those from cell blocks.

  4. Decentralized control of large-scale systems: Fixed modes, sensitivity and parametric robustness. Ph.D. Thesis - Universite Paul Sabatier, 1985

    NASA Technical Reports Server (NTRS)

    Tarras, A.

    1987-01-01

    The problem of stabilization/pole placement under structural constraints of large scale linear systems is discussed. The existence of a solution to this problem is expressed in terms of fixed modes. The aim is to provide a bibliographic survey of the available results concerning the fixed modes (characterization, elimination, control structure selection to avoid them, control design in their absence) and to present the author's contribution to this problem which can be summarized by the use of the mode sensitivity concept to detect or to avoid them, the use of vibrational control to stabilize them, and the addition of parametric robustness considerations to design an optimal decentralized robust control.

  5. The identification of novel loci required for appropriate nodule development in Medicago truncatula.

    PubMed

    Domonkos, Agota; Horvath, Beatrix; Marsh, John F; Halasz, Gabor; Ayaydin, Ferhan; Oldroyd, Giles E D; Kalo, Peter

    2013-10-11

    The formation of functional symbiotic nodules is the result of a coordinated developmental program between legumes and rhizobial bacteria. Genetic analyses in legumes have been used to dissect the signaling processes required for establishing the legume-rhizobial endosymbiotic association. Compared to the early events of the symbiotic interaction, less attention has been paid to plant loci required for rhizobial colonization and the functioning of the nodule. Here we describe the identification and characterization of a number of new genetic loci in Medicago truncatula that are required for the development of effective nitrogen fixing nodules. Approximately 38,000 EMS and fast neutron mutagenized Medicago truncatula seedlings were screened for defects in symbiotic nitrogen fixation. Mutant plants impaired in nodule development and efficient nitrogen fixation were selected for further genetic and phenotypic analysis. Nine mutants completely lacking in nodule formation (Nod-) represented six complementation groups of which two novel loci have been identified. Eight mutants with ineffective nodules (Fix-) represented seven complementation groups, out of which five were new monogenic loci. The Fix- M. truncatula mutants showed symptoms of nitrogen deficiency and developed small white nodules. Microscopic analysis of Fix- nodules revealed that the mutants have defects in the release of rhizobia from infection threads, differentiation of rhizobia and maintenance of persistence of bacteria in nodule cells. Additionally, we monitored the transcriptional activity of symbiosis specific genes to define what transcriptional stage of the symbiotic process is blocked in each of the Fix- mutants. Based on the phenotypic and gene expression analysis a functional hierarchy of the FIX genes is proposed. The new symbiotic loci of M. truncatula isolated in this study provide the foundation for further characterization of the mechanisms underpinning nodulation, in particular the later stages associated with bacterial release and nodule function.

  6. Real-Time Feedback Control of Flow-Induced Cavity Tones. Part 1; Fixed-Gain Control

    NASA Technical Reports Server (NTRS)

    Kegerise, M. A.; Cabell, R. H.; Cattafesta, L. N., III

    2006-01-01

    A generalized predictive control (GPC) algorithm was formulated and applied to the cavity flow-tone problem. The control algorithm demonstrated multiple Rossiter-mode suppression at fixed Mach numbers ranging from 0.275 to 0.38. Controller performance was evaluated with a measure of output disturbance rejection and an input sensitivity transfer function. The results suggest that disturbances entering the cavity flow are collocated with the control input at the cavity leading edge. In that case, only tonal components of the cavity wall-pressure fluctuations can be suppressed and arbitrary broadband pressure reduction is not possible with the present sensor/actuator arrangement. In the control-algorithm development, the cavity dynamics were treated as linear and time invariant (LTI) for a fixed Mach number. The experimental results lend support to that treatment.

  7. Direct sectioning of unembedded cartilage: a simple method for microscopical and histochemical studies on chondrocytes and extracellular matrix.

    PubMed

    Stockert, J C; Del Castillo, P

    1990-01-01

    On account of the rigidity and compact structure of the hyaline cartilage, unfixed or formaldehyde fixed samples of this tissue can be directly sectioned by using a conventional ultramicrotome and a glass knife. This simple method allows to obtain microscopical sections from unembedded cartilage blocks, which show a well preserved histological structure and are very suitable to carry out morphological and histochemical studies on chondrocytes and cartilaginous matrix.

  8. Preparation and Purification of Multigram Quantities of TAX and SEX.

    DTIC Science & Technology

    1981-12-01

    Synthesis Purification Nitrolysis 2L AS[TNIACT (Cletiloe -m powowe0m N noeaemy and Identify by block number) This final report describes the multigram... synthesis and purification of 3 kg of 1-acetylhexahydro-3,5-dinitro-1,3,5-triazine (TAX) and the feasibility of producing kilogram quantities of l...residual impurities; (3) demonstrate the feasibility of the synthesis approach on a one-pound batch reaction; and (4) provide a cost-plus-fixed-fee estimate

  9. Maintenance Resources by Building Use for Installations in Germany

    DTIC Science & Technology

    1991-11-01

    125125. .01 0531140 STEEL ( INSULATED ) PAINTED INTERIOR DOOR 124956. .01 0432710 DOUBLE PANE STEEL FIXED WNDW. 1ST FLOOR 124922. .01 1131200 QUARTZ...FINISH 8507. .00 0535400 ALUMINUM DOUBLE ROLL-UP INTERIOR DOOR 8490. .00 0424310 ALUMINUM LOUVERED EXT DOORS 7973. .00 0421340 STEEL ( INSUL CORE) UNPUT...H.P. 0831130 20 1.09 Clay Block (Painted) Interior 0612200 21 1.08 Wall Sink. Stainless Steel 0811F00 22 1.03 Steel (Painted) Exterior Door 0421210 23

  10. Dump assembly

    DOEpatents

    Goldmann, Louis H.

    1986-01-01

    A dump assembly having a fixed conduit and a rotatable conduit provided with overlapping plates, respectively, at their adjacent ends. The plates are formed with openings, respectively, normally offset from each other to block flow. The other end of the rotatable conduit is provided with means for securing the open end of a filled container thereto. Rotation of the rotatable conduit raises and inverts the container to empty the contents while concurrently aligning the conduit openings to permit flow of material therethrough.

  11. On optimizing the blocking step of indirect enzyme-linked immunosorbent assay for Epstein-Barr virus serology.

    PubMed

    Lim, Chun Shen; Krishnan, Gopala; Sam, Choon Kook; Ng, Ching Ching

    2013-01-16

    Because blocking agent occupies most binding surface of a solid phase, its ability to prevent nonspecific binding determines the signal-to-noise ratio (SNR) and reliability of an enzyme-linked immunosorbent assay (ELISA). We demonstrate a stepwise approach to seek a compatible blocking buffer for indirect ELISA, via a case-control study (n=176) of Epstein-Barr virus (EBV)-associated nasopharyngeal carcinoma (NPC). Regardless of case-control status, we found that synthetic polymer blocking agents, mainly Ficoll and poly(vinyl alcohol) (PVA) were able to provide homogeneous backgrounds among samples, as opposed to commonly used blocking agents, notably nonfat dry milk (NFDM). The SNRs for NPC samples that correspond to blocking using PVA were approximately 3-fold, on average, higher than those blocking using NFDM. Both intra- and inter-assay precisions of PVA-based assays were <14%. A blocking agent of choice should have tolerable sample backgrounds from both cases and controls to ensure the reliability of an immunoassay. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Tunable Encapsulation Structure of Block Copolymer Coated Single-Walled Carbon Nanotubes in Aqueous Solution

    DOE PAGES

    Han, Youngkyu; Ahn, Suk-Kyun; Zhang, Zhe; ...

    2015-05-15

    The nano-sized and shape-tunable molecular building blocks can provide great opportunities for the fabrication of precisely controlled nanostructures. In this work, we have fabricated a molecular building block of single-walled carbon nanotubes (SWNTs) coated by PPO-PEO-PPO block copolymers whose encapsulation structure can be controlled via temperature or addition of small molecules. The structure and optical properties of SWNT-block copolymers have been investigated by small angle neutron scattering (SANS), ultraviolet-visible (UV-vis) spectroscopy, atomic force microscopy (AFM), and molecular dynamics (MD) simulation. The structure of the hydrated block copolymer layer surrounding SWNT can be controlled reversibly by varying temperature as well asmore » by irreversibly adding 5-methylsalicylic acid (5MS). Increasing hydrophobicity of the polymers with temperature and strong tendency of 5MS to interact with both block copolymers and orbitals of the SWNTs are likely to be responsible for the significant structural change of the block copolymer encapsulation layer, from loose corona shell to tightly encapsulating compact shell. These result shows an efficient and simple way to fabricate and manipulate carbon-based nano building blocks in aqueous systems with tunable structure.« less

  13. A multimodal micro air vehicle for autonomous flight in near-earth environments

    NASA Astrophysics Data System (ADS)

    Green, William Edward

    Reconnaissance, surveillance, and search-and-rescue missions in near-Earth environments such as caves, forests, and urban areas pose many new challenges to command and control (C2) teams. Of great significance is how to acquire situational awareness when access to the scene is blocked by enemy fire, rubble, or other occlusions. Small bird-sized aerial robots are expendable and can fly over obstacles and through small openings to assist in the acquisition and distribution of intelligence. However, limited flying space and densely populated obstacle fields requires a vehicle that is capable of hovering, but also maneuverable. A secondary flight mode was incorporated into a fixed-wing aircraft to preserve its maneuverability while adding the capability of hovering. An inertial measurement sensor and onboard flight control system were interfaced and used to transition the hybrid prototype from cruise to hover flight and sustain a hover autonomously. Furthermore, the hovering flight mode can be used to maneuver the aircraft through small openings such as doorways. An ultrasonic and infrared sensor suite was designed to follow exterior building walls until an ingress route was detected. Reactive control was then used to traverse the doorway and gather reconnaissance. Entering a dangerous environment to gather intelligence autonomously will provide an invaluable resource to any C2 team. The holistic approach of platform development, sensor suite design, and control serves as the philosophy of this work.

  14. Postlaminectomy Bone and Scar Formations in Presence of Ankaferd Blood Stopper and Bitter Melon (Momordica Charantia): An Experimental Study.

    PubMed

    Kuruoglu, Enis; Onger, Mehmet Emin; Marangoz, Abdullah Hilmi; Kocacan, Suleyman Emre; Cokluk, Cengiz; Kaplan, Suleyman

    2017-01-01

    A quantitative model of postlaminectomy was designed in rats. The effects of Momordica Charantia (MC) and Ankaferd blood stopper (ABS) on the bone and scar formation after laminectomy were concurrently evaluated. Eighteen adult Wistar albino rats underwent lumbar laminectomy at L2-L3 vertebral levels, and were randomly assigned to one of three groups of six rats each. The Treatment group received MC and ABS treatment and the Control group was left untreated. Rats were sacrificed 4 weeks after treatment. Then; the lumbar spine was excised en-block, fixed and decalcified. Sections were stained with hematoxylin and eosin (H&E) and Masson"s trichrome, and evaluated for peridural fibrosis (PF), new bone formation, and vascular proliferation. Total volume of new bone in the MC group was significantly increased in comparison to the Control group (p < 0.05). Also; there was highly significant increase in terms of the total volume of fibrous tissue in the MC and ABS groups when compared with the Control group (p < 0.01). Besides; there was a highly significant difference between the MC and the Control groups (p < 0.01) in point of total volume of vessel. Both MC and ABS are not convenient to prevent the PF formation and MC may promote new bone formation and angiogenesis after lumbar laminectomy in rats.

  15. Structural and vascular response of normal and obstructed rabbit whole bladders to distension.

    PubMed

    Matsumoto, Seiji; Chichester, Paul; Kogan, Barry A; Levin, Robert M

    2003-12-01

    To investigate the structural and morphologic effect of distension after partial outlet obstruction in rabbits. Thirty male New Zealand white rabbits were separated into two groups: control (sham) and partial outlet obstruction (3 weeks). Three rabbits from each group were distended to 5%, 25%, 50%, 100%, and 125% of capacity. Each bladder was fixed at the volume in buffered formalin for 6 to 8 hours. Sections of dorsal and ventral bladder were blocked, and cross sections were evaluated. Quantitative morphometry was performed, and CD31 immunohistochemistry was used to characterize the vascularity. Partial outlet obstruction resulted in increased bladder weight and capacity and increased thickness of the mucosa, submucosa, detrusor, and serosa. In the control bladder, the greatest thinning was seen between 5% and 25% capacity, and in the obstructed group, the greatest thinning occurred between 25% and 50%. The level of vascular collapse was significantly greater for the control bladders than for the obstructed bladders at all levels of distension. Finally, the obstructed bladders showed a significantly greater level of vascularity in the submucosa than the control bladders. Normal bladder distension resulted in significant morphologic changes when the bladder was distended to 25% of capacity but changed relatively little between 25% and 125%. However, distension of the obstructed bladder resulted in significant morphologic changes when the bladder was distended from 25% to 50% of capacity but changed relatively little between 50% and 125%.

  16. Finite-Time and Fixed-Time Cluster Synchronization With or Without Pinning Control.

    PubMed

    Liu, Xiwei; Chen, Tianping

    2018-01-01

    In this paper, the finite-time and fixed-time cluster synchronization problem for complex networks with or without pinning control are discussed. Finite-time (or fixed-time) synchronization has been a hot topic in recent years, which means that the network can achieve synchronization in finite-time, and the settling time depends on the initial values for finite-time synchronization (or the settling time is bounded by a constant for any initial values for fixed-time synchronization). To realize the finite-time and fixed-time cluster synchronization, some simple distributed protocols with or without pinning control are designed and the effectiveness is rigorously proved. Several sufficient criteria are also obtained to clarify the effects of coupling terms for finite-time and fixed-time cluster synchronization. Especially, when the cluster number is one, the cluster synchronization becomes the complete synchronization problem; when the network has only one node, the coupling term between nodes will disappear, and the synchronization problem becomes the simplest master-slave case, which also includes the stability problem for nonlinear systems like neural networks. All these cases are also discussed. Finally, numerical simulations are presented to demonstrate the correctness of obtained theoretical results.

  17. Comparing the effects of single shot sciatic nerve block versus posterior capsule local anesthetic infiltration on analgesia and functional outcome after total knee arthroplasty: a prospective, randomized, double-blinded, controlled trial.

    PubMed

    Safa, Ben; Gollish, Jeffrey; Haslam, Lynn; McCartney, Colin J L

    2014-06-01

    Peripheral nerve blocks appear to provide effective analgesia for patients undergoing total knee arthroplasty. Although the literature supports the use of femoral nerve block, addition of sciatic nerve block is controversial. In this study we investigated the value of sciatic nerve block and an alternative technique of posterior capsule local anesthetic infiltration analgesia. 100 patients were prospectively randomized into three groups. Group 1: sciatic nerve block; Group 2: posterior local anesthetic infiltration; Group 3: control. All patients received a femoral nerve block and spinal anesthesia. There were no differences in pain scores between groups. Sciatic nerve block provided a brief clinically insignificant opioid sparing effect. We conclude that sciatic nerve block and posterior local anesthetic infiltration do not provide significant analgesic benefits. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Preparation and development of block copolypeptide vesicles and hydrogels for biological and medical applications.

    PubMed

    Deming, Timothy J

    2014-01-01

    There have been many recent advances in the controlled polymerization of α-amino acid-N-carboxyanhydride (NCA) monomers into well-defined block copolypeptides. Transition metal initiating systems allow block copolypeptide synthesis with excellent control over number and lengths of block segments, chain length distribution, and chain-end functionality. Using this and other methods, block copolypeptides of controlled dimensions have been prepared and their self-assembly into organized structures studied by many research groups. The ability of well-defined block copolypeptides to assemble into supramolecular copolypeptide vesicles and hydrogels has led to the development of these materials for use in biological and medical applications. These assemblies have been found to possess unique properties that are derived from the amino acid building blocks and ordered conformations of the polypeptide segments. Recent work on the incorporation of active and stimulus-responsive functionality in these materials has tremendously increased their potential for use in biological and medical studies. © 2014 Wiley Periodicals, Inc.

  19. Effect of vibratory soldier alarm signals on the foraging behavior of subterranean termites (Isoptera: Rhinotermitidae).

    PubMed

    Inta, R; Evans, T A; Lai, J C S

    2009-02-01

    Termite soldiers produce a vibratory alarm signal to warn conspecific workers. This study recorded and characterized the alarm signals of Coptotermes acinaciformis (Froggatt) (Isoptera: Rhinotermitidae) and then investigated the effect of playing these recorded alarm signals on C. acinaciformis feeding activity. Foraging groups of termites were offered paired wooden blocks: either one block, continuously stimulated with a vibratory alarm signal, paired with a nonstimulated block (the alarm treatment), continuously stimulated with a pink noise signal, paired with a nonstimulated block (control for nonspecific vibrations) or two nonstimulated blocks (control for environmental effects), for 4 wk. The amount of wood eaten in the blocks stimulated by the alarm signals was significantly less than the paired nonstimulated blocks, while there seemed to be no preference in the case of the pink noise playback or control for direction. Importantly, the termites seemed not to have adapted to the recorded alarm signal over the 4-wk duration of the experiment, unlike previous studies using nonbiologically derived signals.

  20. Design and control of a vertical takeoff and landing fixed-wing unmanned aerial vehicle

    NASA Astrophysics Data System (ADS)

    Malang, Yasir

    With the goal of extending capabilities of multi-rotor unmanned aerial vehicles (UAVs) for wetland conservation missions, a novel hybrid aircraft design consisting of four tilting rotors and a fixed wing is designed and built. The tilting rotors and nonlinear aerodynamic effects introduce a control challenge for autonomous flight, and the research focus is to develop and validate an autonomous transition flight controller. The overall controller structure consists of separate cascaded Proportional Integral Derivative (PID) controllers whose gains are scheduled according to the rotors' tilt angle. A control mechanism effectiveness factor is used to mix the multi-rotor and fixed-wing control actuators during transition. A nonlinear flight dynamics model is created and transition stability is shown through MATLAB simulations, which proves gain-scheduled control is a good fit for tilt-rotor aircraft. Experiments carried out using the prototype UAV validate simulation results for VTOL and tilted-rotor flight.

  1. Fixed gain and adaptive techniques for rotorcraft vibration control

    NASA Technical Reports Server (NTRS)

    Roy, R. H.; Saberi, H. A.; Walker, R. A.

    1985-01-01

    The results of an analysis effort performed to demonstrate the feasibility of employing approximate dynamical models and frequency shaped cost functional control law desgin techniques for helicopter vibration suppression are presented. Both fixed gain and adaptive control designs based on linear second order dynamical models were implemented in a detailed Rotor Systems Research Aircraft (RSRA) simulation to validate these active vibration suppression control laws. Approximate models of fuselage flexibility were included in the RSRA simulation in order to more accurately characterize the structural dynamics. The results for both the fixed gain and adaptive approaches are promising and provide a foundation for pursuing further validation in more extensive simulation studies and in wind tunnel and/or flight tests.

  2. Interior Permanent Magnet Reluctance Machine with Brushless Field Excitation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiles, R.H.

    2005-10-07

    In a conventional permanent magnet (PM) machine, the air-gap flux produced by the PM is fixed. It is difficult to enhance the air-gap flux density due to limitations of the PM in a series-magnetic circuit. However, the air-gap flux density can be weakened by using power electronic field weakening to the limit of demagnetization of the PMs. This paper presents the test results of controlling the PM air-gap flux density through the use of a stationary brushless excitation coil in a reluctance interior permanent magnet with brushless field excitation (RIPM-BFE) motor. Through the use of this technology the air-gap fluxmore » density can be either enhanced or weakened. There is no concern with demagnetizing the PMs during field weakening. The leakage flux of the excitation coil through the PMs is blocked. The prototype motor built on this principle confirms the concept of flux enhancement and weakening through the use of excitation coils.« less

  3. Quantum Phase Transitions in Conventional Matrix Product Systems

    NASA Astrophysics Data System (ADS)

    Zhu, Jing-Min; Huang, Fei; Chang, Yan

    2017-02-01

    For matrix product states(MPSs) of one-dimensional spin-1/2 chains, we investigate a new kind of conventional quantum phase transition(QPT). We find that the system has two different ferromagnetic phases; on the line of the two ferromagnetic phases coexisting equally, the system in the thermodynamic limit is in an isolated mediate-coupling state described by a paramagnetic state and is in the same state as the renormalization group fixed point state, the expectation values of the physical quantities are discontinuous, and any two spin blocks of the system have the same geometry quantum discord(GQD) within the range of open interval (0,0.25) and the same classical correlation(CC) within the range of open interval (0,0.75) compared to any phase having no any kind of correlation. We not only realize the control of QPTs but also realize the control of quantum correlation of quantum many-body systems on the critical line by adjusting the environment parameters, which may have potential application in quantum information fields and is helpful to comprehensively and deeply understand the quantum correlation, and the organization and structure of quantum correlation especially for long-range quantum correlation of quantum many-body systems.

  4. High-speed imaging using CMOS image sensor with quasi pixel-wise exposure

    NASA Astrophysics Data System (ADS)

    Sonoda, T.; Nagahara, H.; Endo, K.; Sugiyama, Y.; Taniguchi, R.

    2017-02-01

    Several recent studies in compressive video sensing have realized scene capture beyond the fundamental trade-off limit between spatial resolution and temporal resolution using random space-time sampling. However, most of these studies showed results for higher frame rate video that were produced by simulation experiments or using an optically simulated random sampling camera, because there are currently no commercially available image sensors with random exposure or sampling capabilities. We fabricated a prototype complementary metal oxide semiconductor (CMOS) image sensor with quasi pixel-wise exposure timing that can realize nonuniform space-time sampling. The prototype sensor can reset exposures independently by columns and fix these amount of exposure by rows for each 8x8 pixel block. This CMOS sensor is not fully controllable via the pixels, and has line-dependent controls, but it offers flexibility when compared with regular CMOS or charge-coupled device sensors with global or rolling shutters. We propose a method to realize pseudo-random sampling for high-speed video acquisition that uses the flexibility of the CMOS sensor. We reconstruct the high-speed video sequence from the images produced by pseudo-random sampling using an over-complete dictionary.

  5. Improvised double-embedding technique of minute biopsies: a mega boon to histopathology laboratory.

    PubMed

    Yadav, Lokendra; Thomas, Sarega; Kini, Usha

    2015-01-01

    Optimal orientation of minute mucosal biopsies is essential for a definite diagnosis in gastrointestinal pathology or to visualize neural plexuses in Hirschsprung disease. The problem of minute size of the biopsy and its orientation gets compounded when they are from neonates and mandates exhaustive strip cuts, thus delaying reporting. A modified agar-paraffin technique is aimed to make tissue embedding efficient and user-friendly by inking mapping biopsies (one or more) either fresh or fixed with surgical coloring inks followed by embedding first in agar after orientation and followed thereafter by processing, re-embedding in paraffin wax, sectioning and staining. The tissues in agar paraffin block were found to be well processed, firm, held secure and well preserved. The blocks were easy to cut, with serial sections of thickness 2-3 μ and easy to spread. The colored inks remained permanently on the tissues both in the block as well as on the sections which helped in easy identification of tissues. Agar did not interfere with any stain such as Hematoxylin and Eosin or with histochemical stains, enzyme histochemistry or immunohistochemistry. Inking biopsies and pooling them in a block when obtained from the same patient reduced the number of tissue blocks. The modified agar-paraffin embedding technique is a simple reliable user friendly method that can greatly improve the quality of diagnostic information from minute biopsies by optimal orientation, better quality of sections, faster turnaround time and cost-effectiveness by economizing on the number of paraffin blocks, manpower, chemical reagents and laboratory infrastructure.

  6. High-quality cell block preparation from scraping of conventional cytology slide: a technical report on a modified cytoscrape cell block technique.

    PubMed

    Choi, Y I; Jakhongir, M; Choi, S J; Kim, L; Park, I S; Han, J Y; Kim, J M; Chu, Y C

    2016-12-01

    Immunocytochemistry (ICC) on formalin-fixed paraffin embedded cell blocks is an ancillary tool commonly recruited for differential diagnoses of fine needle aspiration cytology (FNAC) samples. However, the quality of conventional cell blocks in terms of adequate cellularity and evenness of distribution of cytologic material is not always satisfactory for ICC. We introduce a modified agarose-based cytoscrape cell block (CCB) technique that can be effectively used for the preparation of cell blocks from scrapings of conventional FNAC slides. A decoverslipped FNAC slide was mounted with a small amount of water. The cytological material was scraped off the slide into a tissue mold by scraping with a cell scraper. The cytoscrape material was pelleted by centrifugation and pre-embedded in ultra-low gelling temperature agarose and then re-embedded in conventional agarose. The final agarose gel disk was processed and embedded in paraffin. The quality of the ICC on the CCB sections was identical to that of the immunohistochemical stains on histological sections. By scrapping and harvesting the entirety of the cytological material off the cytology slide into a compact agarose cell button, we could avoid the risk of losing diagnostic material during the CCB preparation. This modified CCB technique enables concentration and focusing of minute material while maintaining the entire amount of the cytoscrape material on the viewing spot of the CCB sections. We believe this technique can be effectively used to improve the level of confidence in diagnosis of FNAC especially when the FNAC slides are the only sample available.

  7. The Risk Factors and Clinical Course of Asthma with Fixed Airflow Limitation.

    PubMed

    Pothirat, Chaicharn; Chaiwong, Warawut; Liwsrisakun, Chalerm; Bumroongkit, Chaiwat; Deesomchok, Athavudh; Theerakittikul, Theerakorn; Limsukon, Atikun; Phetsuk, Nittaya

    2016-07-01

    To identify risk factors and clinical course of asthma with fixed airflow limitation. A retrospective case-control study of asthma patients was conducted over a 15-month period. Asthma with fixed airflow limitation patients were defined as chronic asthmatics who had both post-bronchodilator (BD) and on-treatment ratio of forced expiratory in first second (FEV1)/forced vital capacity (FVC) persistently less than 0.7, whereas usual chronic asthma patients had post-BD and/or on-treatment ratio of FEV1/FVC more than 0.7. Serial asthma control tests (ACT), medication used, exacerbations were assessed. The risk factors were analyzed using logistic regression. Clinical characteristics between groups were compared using Student’s t-test and Fisher’s exact test. One hundred twenty from 142 eligible subjects were enrolled. They had asthma with fixed airflow limitation (n = 40) and usual chronic asthma (n = 80). Potential risk factors of asthma with fixed airflow limitation included early disease onset (age <15 years) [(adjusted odd ratio (OR) = 3.9, 95% confidence interval (CI) 1.9-8.3)] with longer disease duration (adjusted OR = 8.4, 95% CI 4.6-15.4 for >30 years). Asthma with fixed airflow limitation patients had lower ACT scores (p<0.001), lower level of asthma control (p<0.001), required more asthma medications (p = 0.002), and higher rates of hospitalization (p = 0.001) than usual chronic asthma. The potential risk factors of asthma with fixed airflow limitation were earlier disease onset and longer disease duration. They had poorer asthma control, more medications needed, and higher rates of exacerbation than usual chronic asthma.

  8. Incorporating engine health monitoring capability into the SSME Block II controller

    NASA Astrophysics Data System (ADS)

    Clarke, James W.; Copa, Roderick J.

    An account is given of the architecture of the SSME's Block II controller's architecture, its incorporation of smart input electronics (SIE), and the potential benefits of this technology in SSME health-monitoring capabilities. SIE allows the Block II controller to conduct its control functions while simultaneously furnishing the computational capabilities and sensor input interface for any newly defined health-monitoring functions. It is expected that the SIE technology may be directly transferred to any follow-on engine design.

  9. Active control of multi-element rotor blade airfoils

    NASA Technical Reports Server (NTRS)

    Torok, Michael S. (Inventor); Moffitt, Robert C. (Inventor); Bagai, Ashish (Inventor)

    2005-01-01

    A multi-element rotor blade includes an individually controllable main element and fixed aerodynamic surface in an aerodynamically efficient location relative to the main element. The main element is controlled to locate the fixed aerodynamic surface in a position to increase lift and/or reduce drag upon the main element at various azimuthal positions during rotation.

  10. Focussed Ion Beam Milling and Scanning Electron Microscopy of Brain Tissue

    PubMed Central

    Knott, Graham; Rosset, Stéphanie; Cantoni, Marco

    2011-01-01

    This protocol describes how biological samples, like brain tissue, can be imaged in three dimensions using the focussed ion beam/scanning electron microscope (FIB/SEM). The samples are fixed with aldehydes, heavy metal stained using osmium tetroxide and uranyl acetate. They are then dehydrated with alcohol and infiltrated with resin, which is then hardened. Using a light microscope and ultramicrotome with glass knives, a small block containing the region interest close to the surface is made. The block is then placed inside the FIB/SEM, and the ion beam used to roughly mill a vertical face along one side of the block, close to this region. Using backscattered electrons to image the underlying structures, a smaller face is then milled with a finer ion beam and the surface scrutinised more closely to determine the exact area of the face to be imaged and milled. The parameters of the microscope are then set so that the face is repeatedly milled and imaged so that serial images are collected through a volume of the block. The image stack will typically contain isotropic voxels with dimenions as small a 4 nm in each direction. This image quality in any imaging plane enables the user to analyse cell ultrastructure at any viewing angle within the image stack. PMID:21775953

  11. Tunable Affinity and Molecular Architecture Lead to Diverse Self-Assembled Supramolecular Structures in Thin Films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsu, Chih-Hao; Dong, Xue-Hui; Lin, Zhiwei

    2015-12-03

    The self-assembly behaviors of specifically designed giant surfactants are systematically studied in thin films using grazing incident X-ray and transmission electron microscopy (TEM), focusing on the effects of head surface functionalities and molecular architectures on nanostructure formation. Two molecular nanoparticles (MNPs) with different affinities, i.e., hydrophilic carboxylic acid functionalized [60]fullerene (AC60) and omniphobic fluorinated polyhedral oligomeric silsesquioxane (FPOSS), are utilized as heads of the giant surfactants. By covalently tethering these functional MNPs onto the chain end or the junction point of polystyrene-block-poly(ethylene oxide) (PS-b-PEO) diblock copolymer, linear and star-like giant surfactants possess distinct molecular architectures are constructed. With fixed lengthmore » of the PEO block, the molecular weight change of the PS block originates the phase formation and transition. Due to the distinct affinity, the AC60-based giant surfactants form two-component morphologies, while three-component morphologies are found in the FPOSS-based ones. A PS block stretching parameter is introduced to characterize the PS chain conformation in different morphologies. The highly diverse self-assembly behaviors and the tunable dimensions in thin films suggest the giant surfactants could be a promising and robust platform for nanolithography applications.« less

  12. Effects of two grading techniques of zirconia material on the fatigue limit of full-contour 3-unit fixed dental prostheses

    PubMed Central

    Villefort, Regina Furbino; Amaral, Marina; Pereira, Gabriel Kalil Rocha; Campos, Tiago Moreira Bastos; Zhang, Yu; Bottino, Marco Antonio; Valandro, Luiz Felipe; de Melo, Renata Marques

    2017-01-01

    Objective This study evaluated the effects of two grading zirconia techniques on the fatigue limit of 3-unit fixed dental prostheses (FDPs). Methods Presintered blocks of 3Y-TZP were milled to obtain sixty-nine 3-unit FDPs, which were divided into three groups (n = 23). The control group (CTL) was sintered and glazed following manufacturer’s instructuctions. The two experimental groups presintered FDPs received a surface silica/glass infiltration treatment before the sintering process. Silica sol-gel group (SSG) was graded by the sol-gel processing route, while the glass-zirconia-glass group (GZG) was graded by an enameling technique. Graded groups did not receive a glaze layer after sintering. All FDPs were then luted with a dual-curing resin cement on composite abutments, embedded in polyurethane and stored in water for five days. The initial load of the fatigue test was calculated based on the results of the monotonic testing applied on three specimens of each group. To determine the fatigue limit, 20 samples of each group were subjected to staircase testing (100,000 cycles/5 Hz). Results The fatigue limits (in Newtons) were CTL = 1607.27, SSG = 1824.31, and GZG = 2006.57, and the Dixon and Mood test indicated statistically significant differences among groups (95% confidence interval). Significance The infiltration of silica and glass on bulk zirconia, by two different grading methods, increased the fatigue limits of monolithic zirconia FDPs. PMID:28118929

  13. Selective polymerization catalysis: controlling the metal chain end group to prepare block copolyesters.

    PubMed

    Zhu, Yunqing; Romain, Charles; Williams, Charlotte K

    2015-09-30

    Selective catalysis is used to prepare block copolyesters by combining ring-opening polymerization of lactones and ring-opening copolymerization of epoxides/anhydrides. By using a dizinc complex with mixtures of up to three different monomers and controlling the chemistry of the Zn-O(polymer chain) it is possible to select for a particular polymerization route and thereby control the composition of block copolyesters.

  14. Dynamics of the near response under natural viewing conditions with an open-view sensor

    PubMed Central

    Chirre, Emmanuel; Prieto, Pedro; Artal, Pablo

    2015-01-01

    We have studied the temporal dynamics of the near response (accommodation, convergence and pupil constriction) in healthy subjects when accommodation was performed under natural binocular and monocular viewing conditions. A binocular open-view multi-sensor based on an invisible infrared Hartmann-Shack sensor was used for non-invasive measurements of both eyes simultaneously in real time at 25Hz. Response times for each process under different conditions were measured. The accommodative responses for binocular vision were faster than for monocular conditions. When one eye was blocked, accommodation and convergence were triggered simultaneously and synchronized, despite the fact that no retinal disparity was available. We found that upon the onset of the near target, the unblocked eye rapidly changes its line of sight to fix it on the stimulus while the blocked eye moves in the same direction, producing the equivalent to a saccade, but then converges to the (blocked) target in synchrony with accommodation. This open-view instrument could be further used for additional experiments with other tasks and conditions. PMID:26504666

  15. Insights into Inverse Materials Design from Phase Transitions in Shape Space

    NASA Astrophysics Data System (ADS)

    Cersonsky, Rose; van Anders, Greg; Dodd, Paul M.; Glotzer, Sharon C.

    In designing new materials for synthesis, the inverse materials design approach posits that, given a structure, we can predict a building block optimized for self- assembly. How does that building block change as pressure is varied to maintain the same crystal structure? We address this question for entropically stabilized colloidal crystals by working in a generalized statistical thermodynamic ensemble where an alchemical potential variable is fixed and its conjugate variable, particle shape, is allowed to fluctuate. We show that there are multiple regions of shape behavior and phase transitions in shape space between these regions. Furthermore, while past literature has looked towards packing arguments for proposing shape-filling candidate building blocks for structure formation, we show that even at very high pressures, a structure will attain lowest free energy by modifying these space-filling shapes. U.S. Army Research Office under Grant Award No. W911NF-10-1-0518, Emerging Frontiers in Research and Innovation Award EFRI-1240264, National Science Foundation Grant Number ACI- 1053575, XSEDE award DMR 140129, Rackham Merit Fellowship Program.

  16. Clarifying the interplate main tectonic elements of Western Anatolia, Turkey by using GNSS velocities and Bouguer gravity anomalies

    NASA Astrophysics Data System (ADS)

    Çırmık, Ayça; Pamukçu, Oya

    2017-10-01

    In this study, the GNSS and gravity data were processed and compared together for examining the continental structures of the Western Anatolia region which has very complicated tectonism. The GNSS data of three national projects were processed and GNSS velocities were found as approximately 25 mm per year towards southwest with respect to the Eurasia fixed frame. In order to investigate the interplate motions of the region, the Anatolian and Aegean block solutions were calculated and the differences in directions and amplitudes of velocities were observed particularly in the Anatolian block solution. Due to the Anatolian block solutions, the study area was grouped into three regions and compared with the tectonic structures as the first time for Western Anatolia by this study. Additionally, W-E and N-S relative GNSS solutions were obtained for observing the possible tectonic borders of the study area. Besides, 2nd order horizontal derivative and low-pass filter methods were applied to Bouguer gravity anomalies and the results of the gravity applications and the changes on crustal-mantle interface were compared with the GNSS horizontal velocities.

  17. Viking Orbiter 1975 articulation control subsystem design analysis

    NASA Technical Reports Server (NTRS)

    Horiuchi, H. H.; Vallas, L. J.

    1973-01-01

    The articulation control subsystem, developed for the Viking Orbiter 1975 spacecraft, is a digital, multiplexed, closed-loop servo system used to control the pointing and positioning of the science scan platform and the high-gain communication antenna, and to position the solar-energy controller louver blades for the thermal control of the propellant tanks. The development, design, and anlaysis of the subsystem is preliminary. The subsystem consists of a block-redundant control electronics multiplexed among eight control actuators. Each electronics block is capable of operating either individually or simultaneously with the second block. This provides the subsystem the capability of simultaneous two-actuator control or a single actuator control with the second block in a stand-by redundant mode. The result of the preliminary design and analysis indicates that the subsystem will perform satisfactorily in the Viking Orbiter 1975 mission. Some of the parameter values used, particularly those in the subsystem dynamics and the error estimates, are preliminary and the results will be updated as more accurate parameter values become available.

  18. Early correction of unilateral scissor bite using transforce appliance and modified twin block appliance

    PubMed Central

    Chandorikar, Harshal; Nagrik, Arun; Bhad, Wasundhara A; Chavan, Santosh J; Doshi, Umal H

    2017-01-01

    Early treatment of scissor bite has been advocated mainly to prevent function jaw shift that can eventually lead to permanent skeletal asymmetry and temporomandibular joint pathosis. Although unilateral scissor bite is more common, most of the times, bilateral mandibular expansion is indicated. Lingual transforce appliance can be useful in such cases. This article presents a patient with unilateral scissor bite in mixed dentition with alveolar narrowing. Transforce appliance was used for scissor bite correction followed by modified twin block appliance for stabilization and settling of occlusion till the eruption of premolars. The case was finished with fixed mechanotherapy. Two years after completion of treatment, results were well maintained. Our results suggest that lingual transforce appliance along with careful management of occlusion is effective in the early management of severe unilateral scissor bite. PMID:28546961

  19. A fuzzy-logic-based controller for methane production in anaerobic fixed-film reactors.

    PubMed

    Robles, A; Latrille, E; Ruano, M V; Steyer, J P

    2017-01-01

    The main objective of this work was to develop a controller for biogas production in continuous anaerobic fixed-bed reactors, which used effluent total volatile fatty acids (VFA) concentration as control input in order to prevent process acidification at closed loop. To this aim, a fuzzy-logic-based control system was developed, tuned and validated in an anaerobic fixed-bed reactor at pilot scale that treated industrial winery wastewater. The proposed controller varied the flow rate of wastewater entering the system as a function of the gaseous outflow rate of methane and VFA concentration. Simulation results show that the proposed controller is capable to achieve great process stability even when operating at high VFA concentrations. Pilot results showed the potential of this control approach to maintain the process working properly under similar conditions to the ones expected at full-scale plants.

  20. Long-term use of nerve block catheters in paediatric patients with cancer related pathologic fractures

    PubMed Central

    BURGOYNE, L. L.; PEREIRAS, L. A.; BERTANI, L. A.; KADDOUM, R. N.; NEEL, M.; FAUGHNAN, L. G.; ANGHELESCU, D. L.

    2013-01-01

    SUMMARY We report three cases of children with osteosarcoma and pathologic fractures treated with long-term continuous nerve blocks for preoperative pain control. One patient with a left distal femoral diaphysis fracture had a femoral continuous nerve block catheter for 41 days without complications. Another with a fractured left proximal femoral shaft had three femoral continuous nerve block catheters for 33, 26 and 22 days respectively. The third patient, whose right proximal humerus was fractured, had a brachial plexus continuous nerve block catheter for 36 days without complication. In our experience, prolonged use of continuous nerve block is safe and effective in children with pathologic fractures for preoperative pain control. PMID:22813501

  1. A Randomized Controlled Trial Examining the Effect of the Addition of the Mandibular Block to Cervical Plexus Block for Carotid Endarterectomy.

    PubMed

    Kavrut Ozturk, Nilgun; Kavakli, Ali Sait; Sagdic, Kadir; Inanoglu, Kerem; Umot Ayoglu, Raif

    2018-04-01

    Although the cervical plexus block generally provides adequate analgesia for carotid endarterectomy, pain caused by metal retractors on the inferior surface of the mandible is not prevented by the cervical block. Different pain relief methods can be performed for patients who experience discomfort in these areas. In this study, the authors evaluated the effect of mandibular block in addition to cervical plexus block on pain scores in carotid endarterectomy. A prospective, randomized, controlled trial. Training and research hospital. Patients who underwent a carotid endarterectomy. Patients scheduled for carotid endarterectomy under cervical plexus block were randomized into 2 groups: group 1 (those who did not receive a mandibular block) and group 2 (those who received a mandibular block). The main purpose of the study was to evaluate the mandibular block in addition to cervical plexus block in terms of intraoperative pain scores. Intraoperative visual analog scale scores were significantly higher in group 1 (p = 0.001). The amounts of supplemental 1% lidocaine and intraoperative intravenous analgesic used were significantly higher in group 1 (p = 0.001 and p = 0.035, respectively). Patient satisfaction scores were significantly lower in group 1 (p = 0.044). The amount of postoperative analgesic used, time to first analgesic requirement, postoperative visual analog scale scores, and surgeon satisfaction scores were similar in both groups. There was no significant difference between the groups with respect to complications. No major neurologic deficits or perioperative mortality were observed. Mandibular block in addition to cervical plexus block provides better intraoperative pain control and greater patient satisfaction than cervical plexus block alone. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Nebivolol and valsartan as a fixed-dose combination for the treatment of hypertension.

    PubMed

    Sander, Gary E; Giles, Thomas D

    2015-04-01

    The fixed-dose combination of nebivolol and valsartan drug has been clinically evaluated and demonstrated to represent a unique combination of nebivolol, a selective β1-adrenoceptor antagonist and a β3-adrenoceptor agonist; β3 receptor activation increases endothelial nitric oxide and produces vasodilation. Valsartan is highly selective angiotensin AT1 receptor blocker and exerts its major pharmacological effect by decreasing angiotensin II-induced vasoconstriction and production of aldosterone. The addition of nebivolol counteracts the effects of increased angiotensin II concentrations resulting from potent AT1 blockade. This review describes a recently completed trial establishing the efficacy of the nebivolol/valsartan combination. This review provides a literature search of pertinent pharmacological and clinical data that describes the mechanisms of both drugs individually and the results of a clinical trial comparing fixed-dose combinations of nebivolol with valsartan as compared with each drug as monotherapy. Fixed-dose combination drugs are intended to improve patient compliance and reduce drug costs, as well as to reduce long-term cardiovascular event rates and block counter-regulatory effects due to monotherapy. The vast majority of hypertensive patients will require at least two medications. We believe that the clinical evidence suggests that the combination of nebivolol with valsartan offers a definite clinical benefit, combining β1-adrenoceptor and angiotensin AT1 receptor blockade with β3 receptor activation and resultant increase in nitric oxide and vasodilation.

  3. 47 CFR 90.476 - Interconnection of fixed stations and certain mobile stations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... mobile stations. 90.476 Section 90.476 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Interconnected Systems § 90.476 Interconnection of fixed stations and certain mobile stations. (a) Fixed stations and...

  4. Globally fixed-time synchronization of coupled neutral-type neural network with mixed time-varying delays.

    PubMed

    Zheng, Mingwen; Li, Lixiang; Peng, Haipeng; Xiao, Jinghua; Yang, Yixian; Zhang, Yanping; Zhao, Hui

    2018-01-01

    This paper mainly studies the globally fixed-time synchronization of a class of coupled neutral-type neural networks with mixed time-varying delays via discontinuous feedback controllers. Compared with the traditional neutral-type neural network model, the model in this paper is more general. A class of general discontinuous feedback controllers are designed. With the help of the definition of fixed-time synchronization, the upper right-hand derivative and a defined simple Lyapunov function, some easily verifiable and extensible synchronization criteria are derived to guarantee the fixed-time synchronization between the drive and response systems. Finally, two numerical simulations are given to verify the correctness of the results.

  5. Globally fixed-time synchronization of coupled neutral-type neural network with mixed time-varying delays

    PubMed Central

    2018-01-01

    This paper mainly studies the globally fixed-time synchronization of a class of coupled neutral-type neural networks with mixed time-varying delays via discontinuous feedback controllers. Compared with the traditional neutral-type neural network model, the model in this paper is more general. A class of general discontinuous feedback controllers are designed. With the help of the definition of fixed-time synchronization, the upper right-hand derivative and a defined simple Lyapunov function, some easily verifiable and extensible synchronization criteria are derived to guarantee the fixed-time synchronization between the drive and response systems. Finally, two numerical simulations are given to verify the correctness of the results. PMID:29370248

  6. Learned helplessness and responses to nerve blocks in chronic low back pain patients.

    PubMed

    Chapman, S L; Brena, S F

    1982-01-01

    In a double-blind study, 67 chronic low back pain patients received 4 lumbar sympathetic nerve blocks, two given with bupivacaine and two given with saline. It was hypothesized that patients showing evidence of 'learned helplessness,' as measured by dependence on habit-forming medications for the pain, low activity levels, and elevated MMPI scores on Hypochondriasis, Depression and Hysteria would show the least reduction in subjective pain intensity following injections with both bupivacaine and saline. It also was hypothesized that placebo responses would be greatest in patients who had a high educational level, were divorced, and had no pending disability claims. Responses 30 min following nerve blocks failed to correlate with these variables. However, decreases in subjective pain intensity 24 h following both types of nerve blocks were greater in patients who showed low levels of pain behavior, who were divorced, and who had no pending disability claims. Decreased pain 24 h following saline injections was significantly related to low scores on the Lie, Defensiveness, Hypochondriasis, and Hysteria scales of the MMPI and to reduced subjective pain intensity following a 6 week comprehensive outpatient pain rehabilitation program. It was concluded that chronic pain patients who are fixed in their focus on pain, high in pain-related behaviors, and low in responsibilities are less likely to respond favorably to nerve blocks and that medical treatment for them needs to be paired with therapies designed to reduce their helplessness.

  7. 49 CFR 236.824 - System, automatic block signal.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false System, automatic block signal. 236.824 Section..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.824 System, automatic block signal. A block signal system wherein the use of each block is...

  8. 49 CFR 236.824 - System, automatic block signal.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false System, automatic block signal. 236.824 Section..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.824 System, automatic block signal. A block signal system wherein the use of each block is...

  9. 49 CFR 236.824 - System, automatic block signal.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false System, automatic block signal. 236.824 Section..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.824 System, automatic block signal. A block signal system wherein the use of each block is...

  10. The modeling of an automotive electronic control system and the application of optimizing methods

    NASA Astrophysics Data System (ADS)

    Zhang, Yansheng; Yang, Zhigang; Zhang, Xiang

    2005-12-01

    Now, MATLAB/SIMULINK software is popularly used by automotive electronic control designers to develop automotive electronic control systems and perform numerical simulations. But they will face problems, such as value initialization in the "integrator" block, conversion among different data types, selection of "if" block and "switch" block, realization of the "if-clause" under multiple options and the auto-switching control, etc. Taking as an example the designing of an Automated Mechanical Transmission (AMT) system, this paper discusses some techniques and methods for modeling the automotive electronic control system with MATLAB/SIMULINK, offering designers some successful examples.

  11. A generic method for projecting and valuing domestic water uses, application to the Mediterranean basin at the 2050 horizon.

    NASA Astrophysics Data System (ADS)

    Neverre, Noémie; Dumas, Patrice

    2014-05-01

    The aim is to be able to assess future domestic water demands in a region with heterogeneous levels of economic development. This work offers an original combination of a quantitative projection of demands (similar to WaterGAP methodology) and an estimation of the marginal benefit of water. This method is applicable to different levels of economic development and usable for large-scale hydroeconomic modelling. The global method consists in building demand functions taking into account the impact of both the price of water and the level of equipment, proxied by economic development, on domestic water demand. Our basis is a 3-blocks inverse demand function: the first block consists of essential water requirements for food and hygiene; the second block matches intermediate needs; and the last block corresponds to additional water consumption, such as outdoor uses, which are the least valued. The volume of the first block is fixed to match recommended basic water requirements from the literature, but we assume that the volume limits of blocks 2 and 3 depend on the level of household equipment and therefore evolve with the level of GDP per capita (structural change), with a saturation. For blocks 1 and 2 we determine the value of water from elasticity, price and quantity data from the literature, using the point-extension method. For block 3, we use a hypothetical zero-cost demand and maximal demand with actual water costs to linearly interpolate the inverse demand function. These functions are calibrated on the 24 countries part of the Mediterranean basin using data from SIMEDD, and are used for the projection and valuation of domestic water demands at the 2050 horizon. They enable to project total water demand, and also the respective shares of the different categories of demand (basic demand, intermediate demand and additional uses). These projections are performed under different combined scenarios of population, GDP and water costs.

  12. Systems Analysis Directorate Activities Summary, May 1976

    DTIC Science & Technology

    1976-06-01

    approach is to assume an attack by force is made on a fixed facility with the intent to remove certain materials or perform sabotage of some portion of...IBPS/»-«/, and DATA ACTL/*--/ in main program at statement numbers TAT00500-550, and move them into a BLOCK DATA subroutine as shown below: 0001...NPQ-••). The variables JJ and IIA are common variables and should not be transferred in a subroutine call statement. (7) Statement numbers 0N2211

  13. Continuous-variable quantum cryptography is secure against non-Gaussian attacks.

    PubMed

    Grosshans, Frédéric; Cerf, Nicolas J

    2004-01-30

    A general study of arbitrary finite-size coherent attacks against continuous-variable quantum cryptographic schemes is presented. It is shown that, if the size of the blocks that can be coherently attacked by an eavesdropper is fixed and much smaller than the key size, then the optimal attack for a given signal-to-noise ratio in the transmission line is an individual Gaussian attack. Consequently, non-Gaussian coherent attacks do not need to be considered in the security analysis of such quantum cryptosystems.

  14. Targeting of the MUC1-C Oncoprotein in Colitis-Associated Colorectal Cancer

    DTIC Science & Technology

    2013-09-01

    effect- level isobologram analysis is shown for ED 90 (), ED 75 (+) and ED 50 (×) with the right side panel indicating the CI index for the...was generated by exposing the cells to fixed IC50 ratios of GO-203, GSK1120212 and the GO- 203/GSK1120212 combination. The multiple effect- level ...Kharbanda S, and Kufe D, MUC1 oncoprotein blocks GSK3β -mediated phosphorylation and degradation of β-catenin. Cancer Res, 2005. 65:10413-22. 11. Rajabi

  15. Protecting quantum memories using coherent parity check codes

    NASA Astrophysics Data System (ADS)

    Roffe, Joschka; Headley, David; Chancellor, Nicholas; Horsman, Dominic; Kendon, Viv

    2018-07-01

    Coherent parity check (CPC) codes are a new framework for the construction of quantum error correction codes that encode multiple qubits per logical block. CPC codes have a canonical structure involving successive rounds of bit and phase parity checks, supplemented by cross-checks to fix the code distance. In this paper, we provide a detailed introduction to CPC codes using conventional quantum circuit notation. We demonstrate the implementation of a CPC code on real hardware, by designing a [[4, 2, 2

  16. Explaining Humanitarian Intervention in Libya and Non-Intervention in Syria

    DTIC Science & Technology

    2012-06-01

    Russia will Veto every attempt to prepare an intervention like in Libya. Michael Heath , “Russia Won’t Allow Libya-Style Syria Solution”, Bloomberg...www.un.org/apps/news/story.asp?NewsID=39935 (accessed February, 20 2012). 295 Ibid. 296 Neil McFarquhar. “U.N. Resolution on Syria Blocked by Russia and...russia_says_nato_exceeds_libya_mandate_fix_urgent/4745764.html (accessed March 30, 2012). 448 Ibid. 449 Michael Heath . “Russia Won’t Allow Libya-Style Syria Solution, Lavrov

  17. Effect of compression wood on leaching of chromium, copper, and arsenic from CCA-C treated red pine (Pinus resinosa Ait.)

    Treesearch

    S. Nami. Kartal; Stan. Lebow

    2000-01-01

    In this study, the effect of compression wood formation on the release rate of chromium, copper, and arsenic elements from red pine (Pinus resinosa Ait) was investigated. Wood blocks from red pine containing compression and normal wood portions were treated with a 1.0% CCA-C solution and were then allowed to fix at 23 * 2*C (74 * 4*F) for 0, 6, 24, 48, 96, 192, and 336...

  18. Dump assembly

    DOEpatents

    Goldmann, L.H.

    1984-12-06

    This is a claim for a dump assembly having a fixed conduit and a rotatable conduit provided with overlapping plates, respectively, at their adjacent ends. The plates are formed with openings, respectively, normally offset from each other to block flow. The other end of the rotatable conduit is provided with means for securing the open end of a filled container thereto. Rotation of the rotatable conduit raises and inverts the container to empty the contents while concurrently aligning the conduit openings to permit flow of material therethrough. 4 figs.

  19. Strategies for Controlled Placement of Nanoscale Building Blocks

    PubMed Central

    2007-01-01

    The capability of placing individual nanoscale building blocks on exact substrate locations in a controlled manner is one of the key requirements to realize future electronic, optical, and magnetic devices and sensors that are composed of such blocks. This article reviews some important advances in the strategies for controlled placement of nanoscale building blocks. In particular, we will overview template assisted placement that utilizes physical, molecular, or electrostatic templates, DNA-programmed assembly, placement using dielectrophoresis, approaches for non-close-packed assembly of spherical particles, and recent development of focused placement schemes including electrostatic funneling, focused placement via molecular gradient patterns, electrodynamic focusing of charged aerosols, and others. PMID:21794185

  20. Controlling charge transport mechanisms in molecular junctions: Distilling thermally induced hopping from coherent-resonant conduction.

    PubMed

    Kim, Hyehwang; Segal, Dvira

    2017-04-28

    The electrical conductance of molecular junctions may depend strongly on the temperature and weakly on molecular length, under two distinct mechanisms: phase-coherent resonant conduction, with charges proceeding via delocalized molecular orbitals, and incoherent thermally assisted multi-step hopping. While in the case of coherent conduction, the temperature dependence arises from the broadening of the Fermi distribution in the metal electrodes, in the latter case it corresponds to electron-vibration interaction effects on the junction. With the objective to distill the thermally activated hopping component, thus exposing intrinsic electron-vibration interaction phenomena on the junction, we suggest the design of molecular junctions with "spacers," extended anchoring groups that act to filter out phase-coherent resonant electrons. Specifically, we study the electrical conductance of fixed-gap and variable-gap junctions that include a tunneling block, with spacers at the boundaries. Using numerical simulations and analytical considerations, we demonstrate that in our design, resonant conduction is suppressed. As a result, the electrical conductance is dominated by two (rather than three) mechanisms: superexchange (deep tunneling) and multi-step thermally induced hopping. We further exemplify our analysis on DNA junctions with an A:T block serving as a tunneling barrier. Here, we show that the electrical conductance is insensitive to the number of G:C base-pairs at the boundaries. This indicates that the tunneling-to-hopping crossover revealed in such sequences truly corresponds to the properties of the A:T barrier.

  1. Development of feedback-speed-control system of fixed-abrasive tool for mat-surface fabrication

    NASA Astrophysics Data System (ADS)

    Yanagihara, K.; Kita, R.

    2018-01-01

    This study deals with the new method to fabricate a mat-surface by using fixed-abrasive tool. Mat-surface is a surface with microscopic irregularities whose dimensions are close to the wavelengths of visible light (400-700 nanometers). In order to develop the new method to fabricate mat-surface without pre-masking and large scale back up facility, utilization of fixed-abrasive tool is discussed. The discussion clarifies that abrasives in shot blasting are given kinetic energy along to only plunge-direction while excluding traverse-direction. If the relative motion between tool and work in fixed-abrasive process can be realized as that in blasting, mat-surface will be accomplished with fixed-abrasive process. To realize the proposed idea, new surface-fabrication system to which is adopted feedback-speed-control of abrasive wheel has been designed. The system consists of micro-computer unit (MPU), work-speed sensor, fixed-abrasive wheel, and wheel driving unit. The system can control relative speed between work and wheel in optimum range to produce mat-surface. Finally experiment to verify the developed system is carried out. The results of experiments show that the developed system is effective and it can produce the surface from grinding to mat-surface seamlessly.

  2. Bicomponent Block Copolymers Derived from One or More Random Copolymers as an Alternative Route to Controllable Phase Behavior

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ashraf, Arman R.; Ryan, Justin J.; Satkowski, Michael M.

    Block copolymers have been extensively studied due to their ability to spontaneously self-organize into a wide variety of morphologies that are valuable in energy-, medical- and conservation-related (nano)technologies. While the phase behavior of bicomponent diblock and triblock copolymers is conventionally governed by temperature and individual block masses, we demonstrate that their phase behavior can alternatively be controlled through the use of blocks with random monomer sequencing. Block random copolymers (BRCs), i.e., diblock copolymers wherein one or both blocks is a random copolymer comprised of A and B repeat units, have been synthesized, and their phase behavior, expressed in terms ofmore » the order-disorder transition (ODT), has been investigated. Our results establish that, depending on the block composition contrast and molecular weight, BRCs can microphase-separate. We also report that the predicted ODT can be generated at relatively constant molecular weight and temperature with these new soft materials. This sequence-controlled synthetic strategy is extended to thermoplastic elastomeric triblock copolymers differing in chemistry and possessing a random-copolymer midblock.« less

  3. Causality constraints in conformal field theory

    DOE PAGES

    Hartman, Thomas; Jain, Sachin; Kundu, Sandipan

    2016-05-17

    Causality places nontrivial constraints on QFT in Lorentzian signature, for example fixing the signs of certain terms in the low energy Lagrangian. In d dimensional conformal field theory, we show how such constraints are encoded in crossing symmetry of Euclidean correlators, and derive analogous constraints directly from the conformal bootstrap (analytically). The bootstrap setup is a Lorentzian four-point function corresponding to propagation through a shockwave. Crossing symmetry fixes the signs of certain log terms that appear in the conformal block expansion, which constrains the interactions of low-lying operators. As an application, we use the bootstrap to rederive the well knownmore » sign constraint on the (Φ) 4 coupling in effective field theory, from a dual CFT. We also find constraints on theories with higher spin conserved currents. As a result, our analysis is restricted to scalar correlators, but we argue that similar methods should also impose nontrivial constraints on the interactions of spinning operators« less

  4. Operator mixing in the ɛ -expansion: Scheme and evanescent-operator independence

    NASA Astrophysics Data System (ADS)

    Di Pietro, Lorenzo; Stamou, Emmanuel

    2018-03-01

    We consider theories with fermionic degrees of freedom that have a fixed point of Wilson-Fisher type in noninteger dimension d =4 -2 ɛ . Due to the presence of evanescent operators, i.e., operators that vanish in integer dimensions, these theories contain families of infinitely many operators that can mix with each other under renormalization. We clarify the dependence of the corresponding anomalous-dimension matrix on the choice of renormalization scheme beyond leading order in ɛ -expansion. In standard choices of scheme, we find that eigenvalues at the fixed point cannot be extracted from a finite-dimensional block. We illustrate in examples a truncation approach to compute the eigenvalues. These are observable scaling dimensions, and, indeed, we find that the dependence on the choice of scheme cancels. As an application, we obtain the IR scaling dimension of four-fermion operators in QED in d =4 -2 ɛ at order O (ɛ2).

  5. Determination of ABO genotypes with DNA extracted from formalin-fixed, paraffin-embedded tissues.

    PubMed

    Yamada, M; Yamamoto, Y; Tanegashima, A; Kane, M; Ikehara, Y; Fukunaga, T; Nishi, K

    1994-01-01

    The gene encoding the specific glycosyltransferases which catalyze the conversion of the H antigen to A or B antigens shows a slight but distinct variation in its allelic nucleotide sequence and can be divided into 6 genotypes when digested with specific restriction enzymes. We extracted DNA from formalin-fixed, paraffin-embedded tissues using SDS/proteinase K treatment followed by phenol/chloroform extraction. The sequence of nucleotides for the A, B and O genes was amplified by the polymerase chain reaction (PCR). DNA fragments of 128 bp and 200 bp could be amplified in the second round of PCR, using an aliquot of the first round PCR product as template. Degraded DNA from paraffin blocks stored for up to 10.7 years could be successfully typed. The ABO genotype was deduced from the digestion patterns with an appropriate combination of restriction enzymes and was compatible with the phenotype obtained from the blood sample.

  6. Direction based Hazard Routing Protocol (DHRP) for disseminating road hazard information using road side infrastructures in VANETs.

    PubMed

    Berlin, M A; Anand, Sheila

    2014-01-01

    This paper presents Direction based Hazard Routing Protocol (DHRP) for disseminating information about fixed road hazards such as road blocks, tree fall, boulders on road, snow pile up, landslide, road maintenance work and other obstacles to the vehicles approaching the hazardous location. The proposed work focuses on dissemination of hazard messages on highways with sparse traffic. The vehicle coming across the hazard would report the presence of the hazard. It is proposed to use Road Side fixed infrastructure Units for reliable and timely delivery of hazard messages to vehicles. The vehicles can then take appropriate safety action to avoid the hazardous location. The proposed protocol has been implemented and tested using SUMO simulator to generate road traffic and NS 2.33 network simulator to analyze the performance of DHRP. The performance of the proposed protocol was also compared with simple flooding protocol and the results are presented.

  7. Paracervical Block for Laminaria Insertion Before Second-Trimester Abortion: A Randomized Controlled Trial.

    PubMed

    Soon, Reni; Tschann, Mary; Salcedo, Jennifer; Stevens, Katelyn; Ahn, Hyeong Jun; Kaneshiro, Bliss

    2017-08-01

    To evaluate the efficacy of a paracervical block to decrease pain during osmotic dilator insertion before second-trimester abortion. In this double-blind, randomized trial, 41 women undergoing Laminaria insertion before a second-trimester abortion received either a paracervical block with 18 mL 1% lidocaine and 2 mL sodium bicarbonate or a sham block. Women were between 14 and 23 6/7 weeks of gestation. The primary outcome was pain immediately after insertion of Laminaria. Women assessed their pain on a 100-mm visual analog scale. Secondary outcomes included assessment of pain at other times during the insertion procedure and overall satisfaction with pain control. To detect a 25-mm difference in pain immediately after Laminaria insertion, at an α of 0.05 and 80% power, we aimed to enroll 20 patients in each arm. From May 2015 to December 2015, 20 women received a paracervical block and 21 received a sham block. Groups were similar in demographics, including parity, history of surgical abortion, and number of Laminaria placed. The paracervical block reduced pain after Laminaria insertion (median scores 13 mm [interquartile range 2-39] compared with 54 mm [interquartile range 27-61], P=.01, 95% CI -47.0 to -4.0). Women who received a paracervical block also reported higher satisfaction with overall pain control throughout the entire Laminaria insertion procedure (median scores 95 mm [interquartile range 78-100] compared with 70 mm [interquartile range 44-90], P=.05, 95% CI 0.0-37.0). Paracervical block is effective at reducing the pain of Laminaria insertion. Additionally, a paracervical block increases overall patient satisfaction with pain control during Laminaria placement. ClinicalTrials.gov, NCT02454296.

  8. A method of calculating the performance of controllable propellers with sample computations

    NASA Technical Reports Server (NTRS)

    Hartman, Edwin P

    1934-01-01

    This paper contains a series of calculations showing how the performance of controllable propellers may be derived from data on fixed-pitch propellers given in N.A.C.A. Technical Report No. 350, or from similar data. Sample calculations are given which compare the performance of airplanes with fixed-pitch and with controllable propellers. The gain in performance with controllable propellers is shown to be largely due to the increased power available, rather than to an increase in efficiency. Controllable propellers are of particular advantage when used with geared and with supercharged engines. A controllable propeller reduces the take-off run, increases the rate of climb and the ceiling, but does not increase the high speed, except when operating above the design altitude of the previously used fixed-pitch propeller or when that propeller was designed for other than high speed.

  9. 40 CFR Table 1 to Subpart Sssss of... - Emission Limits

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... that are controlled with a thermal or catalytic oxidizer a. The 3-hour block average THC concentration... the outlet of the control device; or b. The 3-hour block average THC mass emissions rate must be... than a thermal or catalytic oxidizer a. The 3-hour block average THC concentration must not exceed 20...

  10. 40 CFR Table 1 to Subpart Sssss of... - Emission Limits

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... that are controlled with a thermal or catalytic oxidizer a. The 3-hour block average THC concentration... the outlet of the control device; or b. The 3-hour block average THC mass emissions rate must be... than a thermal or catalytic oxidizer a. The 3-hour block average THC concentration must not exceed 20...

  11. 40 CFR Table 1 to Subpart Sssss of... - Emission Limits

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... that are controlled with a thermal or catalytic oxidizer a. The 3-hour block average THC concentration... the outlet of the control device; or b. The 3-hour block average THC mass emissions rate must be... than a thermal or catalytic oxidizer a. The 3-hour block average THC concentration must not exceed 20...

  12. 40 CFR Table 1 to Subpart Sssss of... - Emission Limits

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... that are controlled with a thermal or catalytic oxidizer a. The 3-hour block average THC concentration... the outlet of the control device; or b. The 3-hour block average THC mass emissions rate must be... than a thermal or catalytic oxidizer a. The 3-hour block average THC concentration must not exceed 20...

  13. 40 CFR Table 1 to Subpart Sssss of... - Emission Limits

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... that are controlled with a thermal or catalytic oxidizer a. The 3-hour block average THC concentration... the outlet of the control device; or b. The 3-hour block average THC mass emissions rate must be... than a thermal or catalytic oxidizer a. The 3-hour block average THC concentration must not exceed 20...

  14. 15 CFR Supplement No. 2 to Part 752 - Instructions for Completing Form BIS-748P-A, “Item Annex”

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... within the lines for each block or box. Block 1: Application Control No. Enter the application control... or reexport a computer or equipment that contains a computer. Instructions on calculating the APP are... processing of your application. Block 24: Continuation of Additional Information. Enter any identifying...

  15. 15 CFR Supplement No. 2 to Part 752 - Instructions for Completing Form BIS-748P-B, “Item Annex”

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... within the lines for each block or box. Block 1: Application Control No. Enter the application control... or reexport a computer or equipment that contains a computer. Instructions on calculating the APP are... processing of your application. Block 24: Continuation of Additional Information. Enter any identifying...

  16. 15 CFR Supplement No. 2 to Part 752 - Instructions for Completing Form BIS-748P-B, “Item Annex”

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... within the lines for each block or box. Block 1: Application Control No. Enter the application control... or reexport a computer or equipment that contains a computer. Instructions on calculating the APP are... processing of your application. Block 24: Continuation of Additional Information. Enter any identifying...

  17. 15 CFR Supplement No. 2 to Part 752 - Instructions for Completing Form BIS-748P-B, “Item Annex”

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... within the lines for each block or box. Block 1: Application Control No. Enter the application control... or reexport a computer or equipment that contains a computer. Instructions on calculating the APP are... processing of your application. Block 24: Continuation of Additional Information. Enter any identifying...

  18. Comparison of the Effect of Continuous Femoral Nerve Block and Adductor Canal Block after Primary Total Knee Arthroplasty.

    PubMed

    Seo, Seung Suk; Kim, Ok Gul; Seo, Jin Hyeok; Kim, Do Hoon; Kim, Youn Gu; Park, Beyoung Yun

    2017-09-01

    This study aimed to compare the effects of femoral nerve block and adductor canal block on postoperative pain, quadriceps strength, and walking ability after primary total knee arthroplasty. Between November 2014 and February 2015, 60 patients underwent primary total knee arthroplasty. Thirty patients received femoral nerve block and the other 30 received adductor canal block for postoperative pain control. Before spinal anesthesia, the patients received nerve block via a catheter (20 mL 0.75% ropivacaine was administered initially, followed by intermittent bolus injection of 10 mL 0.2% ropivacaine every 6 hours for 3 days). The catheters were maintained in the exact location of nerve block in 24 patients in the femoral nerve block group and in 19 patients in the adductor canal block group. Data collection was carried out from these 43 patients. To evaluate postoperative pain control, the numerical rating scale scores at rest and 45° flexion of the knee were recorded. To evaluate quadriceps strength, manual muscle testing was performed. Walking ability was assessed using the Timed Up and Go test. We also evaluated analgesic consumption and complications of peripheral nerve block. No significant intergroup difference was observed in the numerical rating scale scores at rest and 45° flexion of the knee on postoperative days 1, 2, 3, and 7. The adductor canal block group had significantly greater quadriceps strength than did the femoral nerve block group, as assessed by manual muscle testing on postoperative days 1, 2, and 3. The 2 groups showed no difference in walking ability on postoperative day 1, but on postoperative days 2, 3, walking ability was significantly better in the adductor canal block group than in the femoral nerve block group. No significant intergroup difference was observed in analgesic consumption. The groups showed no difference in postoperative pain control. Adductor canal block was superior to femoral nerve block in preserving quadriceps strength and walking ability. However, adductor canal block was inferior to femoral nerve block in maintaining the exact location of the catheter.

  19. 3DGRAPE - THREE DIMENSIONAL GRIDS ABOUT ANYTHING BY POISSON'S EQUATION

    NASA Technical Reports Server (NTRS)

    Sorenson, R. L.

    1994-01-01

    The ability to treat arbitrary boundary shapes is one of the most desirable characteristics of a method for generating grids. 3DGRAPE is designed to make computational grids in or about almost any shape. These grids are generated by the solution of Poisson's differential equations in three dimensions. The program automatically finds its own values for inhomogeneous terms which give near-orthogonality and controlled grid cell height at boundaries. Grids generated by 3DGRAPE have been applied to both viscous and inviscid aerodynamic problems, and to problems in other fluid-dynamic areas. 3DGRAPE uses zones to solve the problem of warping one cube into the physical domain in real-world computational fluid dynamics problems. In a zonal approach, a physical domain is divided into regions, each of which maps into its own computational cube. It is believed that even the most complicated physical region can be divided into zones, and since it is possible to warp a cube into each zone, a grid generator which is oriented to zones and allows communication across zonal boundaries (where appropriate) solves the problem of topological complexity. 3DGRAPE expects to read in already-distributed x,y,z coordinates on the bodies of interest, coordinates which will remain fixed during the entire grid-generation process. The 3DGRAPE code makes no attempt to fit given body shapes and redistribute points thereon. Body-fitting is a formidable problem in itself. The user must either be working with some simple analytical body shape, upon which a simple analytical distribution can be easily effected, or must have available some sophisticated stand-alone body-fitting software. 3DGRAPE does not require the user to supply the block-to-block boundaries nor the shapes of the distribution of points. 3DGRAPE will typically supply those block-to-block boundaries simply as surfaces in the elliptic grid. Thus at block-to-block boundaries the following conditions are obtained: (1) grids lines will match up as they approach the block-to-block boundary from either side, (2) grid lines will cross the boundary with no slope discontinuity, (3) the spacing of points along the line piercing the boundary will be continuous, (4) the shape of the boundary will be consistent with the surrounding grid, and (5) the distribution of points on the boundary will be reasonable in view of the surrounding grid. 3DGRAPE offers a powerful building-block approach to complex 3-D grid generation, but is a low-level tool. Users may build each face of each block as they wish, from a wide variety of resources. 3DGRAPE uses point-successive-over-relaxation (point-SOR) to solve the Poisson equations. This method is slow, although it does vectorize nicely. Any number of sophisticated graphics programs may be used on the stored output file of 3DGRAPE though it lacks interactive graphics. Versatility was a prominent consideration in developing the code. The block structure allows a great latitude in the problems it can treat. As the acronym implies, this program should be able to handle just about any physical region into which a computational cube or cubes can be warped. 3DGRAPE was written in FORTRAN 77 and should be machine independent. It was originally developed on a Cray under COS and tested on a MicroVAX 3200 under VMS 5.1.

  20. 40 CFR 265.1085 - Standards: Tanks.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... controls shall use one of the following tanks: (1) A fixed-roof tank equipped with an internal floating... equipped with an external floating roof in accordance with the requirements specified in paragraph (f) of... controls air pollutant emissions from a tank using a fixed-roof with an internal floating roof shall meet...

  1. Microstructure synthesis control of biological polyhydroxyalkanoates with mass spectrometry

    NASA Astrophysics Data System (ADS)

    Pederson, Erik Norman

    Polyhydroxyalkanoates (PHA's) are a class of biologically produced polymers, or plastic, that is synthesized by various microorganisms. PHA's are made from biorenewable resources and are fully biodegradable and biocompatible, making them an environmentally friendly green polymer. A method of incorporating polymer microstructure into the PHA synthesized in Ralstonia eutropha was developed. These microstructures were synthesized with polyhydroxybutyrate (PHB) and poly(hydroxybutyrate-co-hydroxyvalerate) (PHBV) as the polymer domains. To synthesize the PHB V copolymer, the additional presence of valerate was required. To control valerate substrate additions to the bioreactor, an off-gas mass spectrometry (MS) feedback control system was developed. Important process information including the cell physiology, growth kinetics, and product formation kinetics in the bioreactor was obtained with MS and used to control microstructure synthesis. The two polymer microstructures synthesized were core-shell granules and block copolymers. Block copolymers control the structure of the individual polymer chains while core-shell granules control the organization of many polymer chains. Both these microstructures result in properties unattainable by blending the two polymers together. The core-shell structures were synthesized with controlled domain thickness based on a developed model. Different block copolymers compositions were synthesized by varying the switching time of the substrate pulses responsible for block copolymer synthesis. The block copolymers were tested to determine their chemical properties and cast into films to determine the materials properties. These block copolymer films possessed new properties not achieved by copolymers or blends of the two polymers.

  2. A Comparison of Escalating versus Fixed Reinforcement Schedules on Undergraduate Quiz Taking

    ERIC Educational Resources Information Center

    Mahoney, Amanda

    2017-01-01

    Drug abstinence studies indicate that escalating reinforcement schedules maintain abstinence for longer periods than fixed reinforcement schedules. The current study evaluated whether escalating reinforcement schedules would maintain more quiz taking than fixed reinforcement schedules. During baseline and for the control group, bonus points were…

  3. 47 CFR 22.603 - 488-494 MHz fixed service in Hawaii.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false 488-494 MHz fixed service in Hawaii. 22.603 Section 22.603 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER SERVICES... fixed service in Hawaii. Before filing applications for authorization of inter-island control and/or...

  4. Transversus abdominal plane block for postoperative analgesia: a systematic review and meta-analysis of randomized-controlled trials.

    PubMed

    Brogi, Etrusca; Kazan, Roy; Cyr, Shantale; Giunta, Francesco; Hemmerling, Thomas M

    2016-10-01

    The transversus abdominal plane (TAP) block has been described as an effective pain control technique after abdominal surgery. We performed a systematic review and meta-analysis of randomized-controlled trials (RCTs) to account for the increasing number of TAP block studies appearing in the literature. The primary outcome we examined was the effect of TAP block on the postoperative pain score at six, 12, and 24 hr. The secondary outcome was 24-hr morphine consumption. We searched the United States National Library of Medicine database, the Excerpta Medica database, and the Cochrane Central Register of Controlled Clinical Studies and identified RCTs focusing on the analgesic efficacy of TAP block compared with a control group [i.e., placebo, epidural analgesia, intrathecal morphine (ITM), and ilioinguinal nerve block after abdominal surgery]. Meta-analyses were performed on postoperative pain scores at rest at six, 12, and 24 hr (visual analogue scale, 0-10) and on 24-hr opioid consumption. In the 51 trials identified, compared with placebo, TAP block reduced the VAS for pain at six hours by 1.4 (95% confidence interval [CI], -1.9 to -0.8; P < 0.001), at 12 hr by 2.0 (95% CI, -2.7 to -1.4; P < 0.001), and at 24 hr by 1.2 (95% CI, -1.6 to -0.8; P < 0.001). Similarly, compared with placebo, TAP block reduced morphine consumption at 24 hr after surgery (mean difference, -14.7 mg; 95% CI, -18.4 to -11.0; P < 0.001). We observed this reduction in pain scores and morphine consumption in the TAP block group after gynecological surgery, appendectomy, inguinal surgery, bariatric surgery, and urological surgery. Nevertheless, separate analysis of the studies comparing ITM with TAP block revealed that ITM seemed to have a greater analgesic efficacy. The TAP block can play an important role in the management of pain after abdominal surgery by reducing both pain scores and 24-hr morphine consumption. It may have particular utility when neuraxial techniques or opioids are contraindicated.

  5. Sintering behavior and mechanical properties of zirconia compacts fabricated by uniaxial press forming.

    PubMed

    Oh, Gye-Jeong; Yun, Kwi-Dug; Lee, Kwang-Min; Lim, Hyun-Pil; Park, Sang-Won

    2010-09-01

    The purpose of this study was to compare the linear sintering behavior of presintered zirconia blocks of various densities. The mechanical properties of the resulting sintered zirconia blocks were then analyzed. Three experimental groups of dental zirconia blocks, with a different presintering density each, were designed in the present study. Kavo Everest® ZS blanks (Kavo, Biberach, Germany) were used as a control group. The experimental group blocks were fabricated from commercial yttria-stabilized tetragonal zirconia powder (KZ-3YF (SD) Type A, KCM. Corporation, Nagoya, Japan). The biaxial flexural strengths, microhardnesses, and microstructures of the sintered blocks were then investigated. The linear sintering shrinkages of blocks were calculated and compared. Despite their different presintered densities, the sintered blocks of the control and experimental groups showed similar mechanical properties. However, the sintered block had different linear sintering shrinkage rate depending on the density of the presintered block. As the density of the presintered block increased, the linear sintering shrinkage decreased. In the experimental blocks, the three sectioned pieces of each block showed the different linear shrinkage depending on the area. The tops of the experimental blocks showed the lowest linear sintering shrinkage, whereas the bottoms of the experimental blocks showed the highest linear sintering shrinkage. Within the limitations of this study, the density difference of the presintered zirconia block did not affect the mechanical properties of the sintered zirconia block, but affected the linear sintering shrinkage of the zirconia block.

  6. Sintering behavior and mechanical properties of zirconia compacts fabricated by uniaxial press forming

    PubMed Central

    Oh, Gye-Jeong; Yun, Kwi-Dug; Lee, Kwang-Min; Lim, Hyun-Pil

    2010-01-01

    PURPOSE The purpose of this study was to compare the linear sintering behavior of presintered zirconia blocks of various densities. The mechanical properties of the resulting sintered zirconia blocks were then analyzed. MATERIALS AND METHODS Three experimental groups of dental zirconia blocks, with a different presintering density each, were designed in the present study. Kavo Everest® ZS blanks (Kavo, Biberach, Germany) were used as a control group. The experimental group blocks were fabricated from commercial yttria-stabilized tetragonal zirconia powder (KZ-3YF (SD) Type A, KCM. Corporation, Nagoya, Japan). The biaxial flexural strengths, microhardnesses, and microstructures of the sintered blocks were then investigated. The linear sintering shrinkages of blocks were calculated and compared. RESULTS Despite their different presintered densities, the sintered blocks of the control and experimental groups showed similar mechanical properties. However, the sintered block had different linear sintering shrinkage rate depending on the density of the presintered block. As the density of the presintered block increased, the linear sintering shrinkage decreased. In the experimental blocks, the three sectioned pieces of each block showed the different linear shrinkage depending on the area. The tops of the experimental blocks showed the lowest linear sintering shrinkage, whereas the bottoms of the experimental blocks showed the highest linear sintering shrinkage. CONCLUSION Within the limitations of this study, the density difference of the presintered zirconia block did not affect the mechanical properties of the sintered zirconia block, but affected the linear sintering shrinkage of the zirconia block. PMID:21165274

  7. Effect of acute psychological stress on response inhibition: An event-related potential study.

    PubMed

    Qi, Mingming; Gao, Heming; Liu, Guangyuan

    2017-04-14

    This study aimed to investigate the effect of acute psychological stress on response inhibition and its electrophysiological correlates using a dual-task paradigm. Acute stress was induced by a primary task (mental arithmetic task), which consisted of a stress block and a control block. Response inhibition was measured using a secondary task (Go/NoGo task). In each trial, a Go/NoGo stimulus was presented immediately after the mental arithmetic task. The results revealed increased subjective stress and negative affect for the stress relative to control block, suggesting that the mental arithmetic task triggered a reliable stress response. ERPs locked to the Go/NoGo stimuli revealed that decreased P2 and increased N2 components were evoked for the stress block compared to the control block. These results demonstrated that acute psychological stress alters the response inhibition process by reducing the early selective attention process and enhancing the cognitive control process. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Efficacy of popliteal block in postoperative pain control after ankle fracture fixation: a prospective randomized study.

    PubMed

    Goldstein, Rachel Y; Montero, Nicole; Jain, Sudheer K; Egol, Kenneth A; Tejwani, Nirmal C

    2012-10-01

    To compare postoperative pain control in patients treated surgically for ankle fractures who receive popliteal blocks with those who received general anesthesia alone. Institutional Review Board approved prospective randomized study. Metropolitan tertiary-care referral center. All patients being treated with open reduction internal fixation for ankle fractures who met inclusion criteria and consented to participate were enrolled. Patients were randomized to receive either general anesthesia (GETA) or intravenous sedation and popliteal block. Patients were assessed for duration of procedure, total time in the operating room, and postoperative pain at 2, 4, 8, 12, 24, and 48 hours after surgery using a visual analog scale. Fifty-one patients agreed to participate in the study. Twenty-five patients received popliteal block, while 26 patients received GETA. There were no anesthesia-related complications. At 2, 4, and 8 hours postoperatively, patients who underwent GETA demonstrated significantly higher pain. At 12 hours, there was no significant difference between the 2 groups with regard to pain control. However, by 24 hours, those who had received popliteal blocks had significantly higher pain with no difference by 48 hours. Popliteal block provides equivalent postoperative pain control to general anesthesia alone in patients undergoing operative fixation of ankle fractures. However, patients who receive popliteal blocks do experience a significant increase in pain between 12 and 24 hours. Recognition of this "rebound pain" with early narcotic administration may allow patients to have more effective postoperative pain control.

  9. F-16 Simulator for Man-in-the-Loop Testing of Aircraft Control Systems (SIMTACS).

    DTIC Science & Technology

    1987-12-01

    Figures Figure Page 2.1. General Hardware Arrangement..................... 12 3.1. DFCS Longitudinal Control Block Diagram .... 21 3.2. DFCS Gain...Functions for Longitudinal Control 22 3.3. DFCS Lateral-Directional Control Block Diagram........................................... 23 3.4. DFCS Gain...Functions for Lateral-Directional Control........................................... 24 3.5. DFCS Control Surface Mixer....................... 25 3.6

  10. Comparison of radiographic joint space width and magnetic resonance imaging for prediction of knee replacement: A longitudinal case-control study from the Osteoarthritis Initiative.

    PubMed

    Eckstein, Felix; Boudreau, Robert; Wang, Zhijie; Hannon, Michael J; Duryea, Jeff; Wirth, Wolfgang; Cotofana, Sebastian; Guermazi, Ali; Roemer, Frank; Nevitt, Michael; John, Markus R; Ladel, Christoph; Sharma, Leena; Hunter, David J; Kwoh, C Kent

    2016-06-01

    To evaluate whether change in fixed-location measures of radiographic joint space width (JSW) and cartilage thickness by MRI predict knee replacement. Knees replaced between 36 and 60 months' follow-up in the Osteoarthritis Initiative were each matched with one control by age, sex and radiographic status. Radiographic JSW was determined from fixed flexion radiographs and subregional femorotibial cartilage thickness from 3 T MRI. Changes between the annual visit before replacement (T0) and 2 years before T0 (T-2) were compared using conditional logistic regression. One hundred and nineteen knees from 102 participants (55.5 % women; age 64.2 ± 8.7 [mean ± SD] years) were studied. Fixed-location JSW change at 22.5 % from medial to lateral differed more between replaced and control knees (case-control [cc] OR = 1.57; 95 % CI: 1.23-2.01) than minimum medial JSW change (ccOR = 1.38; 95 % CI: 1.11-1.71). Medial femorotibial cartilage loss displayed discrimination similar to minimum JSW, and central tibial cartilage loss similar to fixed-location JSW. Location-independent thinning and thickening scores were elevated prior to knee replacement. Discrimination of structural progression between knee pre-placement cases versus controls was stronger for fixed-location than minimum radiographic JSW. MRI displayed similar discrimination to radiography and suggested greater simultaneous cartilage thickening and loss prior to knee replacement. • Fixed-location JSW predicts surgical knee replacement more strongly than minimum JSW. • MRI predicts knee replacement with similar accuracy to radiographic JSW. • MRI reveals greater cartilage thinning and thickening prior to knee replacement.

  11. Development of a Hardware-in-the-Loop Simulator for Control Moment Gyroscope-Based Attitude Control Systems

    DTIC Science & Technology

    2015-12-01

    angular momentum is simply the scalar value projected along the axis of rotation of the momentum wheel (see Figure 1). Since reaction wheels are fixed ...CMGs generate torque by gimbaling a momentum wheel rotating at a nominally fixed rate [2]. The torque output of a CMG is the cross product of the...notably the fixed skew angle of the original system. The goal of this research is to build upon the previous redesign efforts and develop a four-CMG HIL

  12. Histomorphometric analysis after maxillary sinus floor augmentation using cancellous bone-block allograft.

    PubMed

    Chaushu, Gavriel; Vered, Marilena; Mardinger, Ofer; Nissan, Joseph

    2010-08-01

    Cancellous bone-block allografts may contribute to improved initial implant stability during sinus augmentation in cases with posterior atrophic maxillary ridge height < or =4 mm. The present study histologically and histomorphometrically evaluates the application of cancellous bone-block allografts for maxillary sinus-floor augmentation. Thirty-one consecutive patients, 16 females and 15 males (age range, 25 to 65 years; mean age: 54 +/- 9 years) underwent sinus augmentation with simultaneous implant placement with cancellous bone-block allografts. After 9 months, a second-stage surgery was performed. The previous window location was determined. A cylindrical sample core was collected. All specimens were prepared for histologic and histomorphometric examinations. Seventy-two of 76 implants were clinically osseointegrated (94.7%). All patients received a fixed implant-supported prosthesis. The mean t values of newly formed bone, residual cancellous bone-block allograft, marrow and connective tissue were 26.1% +/- 15% (range: 10% to 58%); 24.7% +/- 19.4% (range: 0.6% to 71%), and 49.2% +/- 20.4% (range: 14.9% to 78.9%), respectively. No statistically significant histomorphometric differences regarding newly formed bone were found between genders (27.02% in males versus 25.68% in females; P = 0.446), ages (29.82% in subjects < or =40 years old versus 24.43% in subjects >40 years old; P = 0.293), presence of membrane perforations (25.5% in non-perforated sinuses versus 27.3% in perforated sinuses; P = 0.427), and residual alveolar bone height (25.85% for residual alveolar bone height <2 mm versus 26.48% for residual alveolar bone height of 2 to 4 mm; P = 0.473). The cancellous bone-block allograft is biocompatible and osteoconductive and permits new bone formation in sinus augmentations with simultaneous implant-placement procedures in extremely atrophic posterior maxillae.

  13. Thermally-induced transition of lamellae orientation in block-copolymer films on ‘neutral’ nanoparticle-coated substrates

    DOE PAGES

    Yager, Kevin G.; Forrey, Christopher; Singh, Gurpreet; ...

    2015-06-01

    Block-copolymer orientation in thin films is controlled by the complex balance between interfacial free energies, including the inter-block segregation strength, the surface tensions of the blocks, and the relative substrate interactions. While block-copolymer lamellae orient horizontally when there is any preferential affinity of one block for the substrate, we recently described how nanoparticle-roughened substrates can be used to modify substrate interactions. We demonstrate how such ‘neutral’ substrates can be combined with control of annealing temperature to generate vertical lamellae orientations throughout a sample, at all thicknesses. We observe an orientational transition from vertical to horizontal lamellae upon heating, as confirmedmore » using a combination of atomic force microscopy (AFM), neutron reflectometry (NR) and rotational small-angle neutron scattering (RSANS). Using molecular dynamics (MD) simulations, we identify substrate-localized distortions to the lamellar morphology as the physical basis of the novel behavior. In particular, under strong segregation conditions, bending of horizontal lamellae induce a large energetic cost. At higher temperatures, the energetic cost of conformal deformations of lamellae over the rough substrate is reduced, returning lamellae to the typical horizontal orientation. Thus, we find that both surface interactions and temperature play a crucial role in dictating block-copolymer lamellae orientation. As a result, our combined experimental and simulation findings suggest that controlling substrate roughness should provide a useful and robust platform for controlling block-copolymer orientation in applications of these materials.« less

  14. Assessing delay and lag in sagittal trunk control using a tracking task.

    PubMed

    Reeves, N Peter; Luis, Abraham; Chan, Elizabeth C; Sal Y Rosas, Victor G; Tanaka, Martin L

    2018-05-17

    Slower trunk muscle responses are linked to back pain and injury. Unfortunately, clinical assessments of spine function do not objectively evaluate this important attribute, which reflects speed of trunk control. Speed of trunk control can be parsed into two components: (1) delay, the time it takes to initiate a movement, and (2) lag, the time it takes to execute a movement once initiated. The goal of this study is to demonstrate a new approach to assess delay and lag in trunk control using a simple tracking task. Ten healthy subjects performed four blocks of six trials of trunk tracking in the sagittal plane. Delay and lag were estimated by modeling trunk control for predictable and unpredictable (control mode) trunk movements in flexion and extension (control direction) at movement amplitudes of 2°, 4°, and 6° (control amplitude). The main effect of control mode, direction, and amplitude of movement were compared between trial blocks to assess secondary influencers (e.g., fatigue). Only control mode was consistent across trial blocks with predictable movements being faster than unpredictable for both delay and lag. Control direction and amplitude effects on delay and lag were consistent across the first two trial blocks and less consistent in later blocks. Given the heterogeneity in the presentation of back pain, clinical assessment of trunk control should include different control modes, directions, and amplitudes. To reduce testing time and the influence of fatigue, we recommend six trials to assess trunk control. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. The biomechanical strength of a hardware-free femoral press-fit method for ACL bone-tendon-bone graft fixation.

    PubMed

    Arnold, M P; Burger, L D; Wirz, D; Goepfert, B; Hirschmann, M T

    2017-04-01

    The purpose was to investigate graft slippage and ultimate load to failure of a femoral press-fit fixation technique for anterior cruciate ligament (ACL) reconstruction. Nine fresh-frozen knees were used. Standardized harvesting of the B-PT-B graft was performed. The femora were cemented into steel rods, and a tunnel was drilled outside-in into the native ACL footprint and expanded using a manual mill bit. The femoral bone block was fixed press-fit. To pull the free end of the graft, it was fixed to a mechanical testing machine using a deep-freezing technique. A motion capture system was used to assess three-dimensional micro-motion. After preconditioning of the graft, 1000 cycles of tensile loading were applied. Finally, an ultimate load to failure test was performed. Graft slippage in mm ultimate load to failure as well as type of failure was noted. In six of the nine measured specimens, a typical pattern of graft slippage was observed during cyclic loading. For technical reasons, the results of three knees had to be discarded. 78.6 % of total graft slippage occurred in the first 100 cycles. Once the block had settled, graft slippage converged to zero, highlighting the importance of initial preconditioning of the graft in the clinical setting. Graft slippage after 1000 cycles varied around 3.4 ± 3.2 mm (R = 1.3-9.8 mm) between the specimens. Ultimate loading (n = 9) revealed two characteristic patterns of failure. In four knees, the tendon ruptured, while in five knees the bone block was pulled out of the femoral tunnel. The median ultimate load to failure was 852 N (R = 448-1349 N). The implant-free femoral press-fit fixation provided adequate primary stability with ultimate load to failure pull forces at least equal to published results for interference screws; hence, its clinical application is shown to be safe.

  16. Improving the fit of implant prosthetics: an in vitro study.

    PubMed

    Yannikakis, Stavros; Prombonas, Anthony

    2013-01-01

    Accurate and passive fit between a prosthesis and its supporting implants has been considered a prerequisite for successful long-term osseointegration. The objective of this in vitro study was to evaluate the strain development during tightening of a five-unit screw-retained superstructure constructed using five different methods. Five-unit screw-retained fixed partial prostheses (n = 25) were fabricated on three implants embedded in an epoxy resin block using five different methods: (1) cobalt-chromium (Co-Cr), plastic cylinders, one-piece cast; (2) Co-Cr, plastic cylinders, framework sectioned, preceramic laser-welding soldering; (3) gold-platinum (Au-Pt), gold cylinders, one-piece cast; (4) Au-Pt, gold cylinders, framework sectioned, preceramic laser-welding soldering; (5) Co-Cr, one-piece cast, and cementation to "passive abutments" (Southern Implants) after final finishing and polishing. Strain gauges (SG) were attached to the fixed partial prosthesis (FPP) and to the resin block to measure the stress created during screw tightening. The combination of Co-Cr alloy and plastic cylinders in a one-piece cast showed such an inadequate fit among the fabricated methods that this group was excluded from the remainder of the experiment. Specimens of Au-Pt cast on gold cylinders in one piece showed higher strain development than the other groups used in this study, with strains ranging from 223.1 to 2,198.1 Μm/m. Sectioning and soldering significantly improved the overall fit. FPPs of Co-Cr in a one-piece cast cemented to "passive abutments" produced the best level of fit, with the least strain development in the prosthesis and the resin block (59 to 204.6 Μm/m). Absolute fit of superstructures on implants is not possible using conventional laboratory procedures. Cementing FPPs onto prefabricated cylinders directly onto the implants significantly reduces strain development compared to the other fabrication methods.

  17. Constraining Puerto Rico - Virgin Islands microplate internal deformation with two decades of GPS observations

    NASA Astrophysics Data System (ADS)

    Lopez, A. M.; Jansma, P. E.; Mattioli, G. S.; James, S. A.; Ihemedu, D.; Quintana, S. M.; Salazar, J. S.

    2011-12-01

    The Puerto Rico - Virgin Island microplate, a crustal block within the deformation region of the Northern Caribbean Plate Boundary Zone has been monitored with campaign and permanent Global Positioning System stations for almost 20 years. Within this time period a total of 37 sites have been used to describe and quantify internal deformation of the plate and estimate elastic strain accumulation along the key geological bounding features. In June 2011, 12 of the 20 sites that comprise the campaign GPS network in Puerto Rico were re-occupied and their results were merged with at least three years of continuous GPS data from the Puerto Rico - Virgin Islands cGPS network. The remaining 8 in PR sites will be reoccupied soon, while sites from the Virgin Islands were last reoccupied in 2007. All data were processed with v5 of GOAII using an APP strategy. Here we present the latest results of the newly computed velocity field of our mixed network in both North America and Caribbean fixed frames employing the latest IGS05 reference frame and updated satellite orbits, earth orientation, and xfiles from JPL. Of particular importance in this study are the results of a three station transect across the Lajas Valley, the most seismically active area on southwestern Puerto Rico. Relative to a fixed velocity for a campaign site on Isla Magueyes in La Parguera, the southernmost site in the Lajas Valley has a residual motion of -4.38±1.39 and 2.41±2.10 mm/yr in the north and east components, respectively. This suggests that there is SSE-directed shortening across a structure located between these two sites. In contrast, sites near Mayagüez are moving toward SW at ˜2 mm/yr relative to La Parguera. These results demonstrate the PRVI block shows small internal deformation in addition to its generally westward rigid block translation relative the stable interior of the Caribbean plate.

  18. Multiple types of synchronization analysis for discontinuous Cohen-Grossberg neural networks with time-varying delays.

    PubMed

    Li, Jiarong; Jiang, Haijun; Hu, Cheng; Yu, Zhiyong

    2018-03-01

    This paper is devoted to the exponential synchronization, finite time synchronization, and fixed-time synchronization of Cohen-Grossberg neural networks (CGNNs) with discontinuous activations and time-varying delays. Discontinuous feedback controller and Novel adaptive feedback controller are designed to realize global exponential synchronization, finite time synchronization and fixed-time synchronization by adjusting the values of the parameters ω in the controller. Furthermore, the settling time of the fixed-time synchronization derived in this paper is less conservative and more accurate. Finally, some numerical examples are provided to show the effectiveness and flexibility of the results derived in this paper. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Receiver-exciter controller design

    NASA Technical Reports Server (NTRS)

    Jansma, P. A.

    1982-01-01

    A description of the general design of both the block 3 and block 4 receiver-exciter controllers for the Deep Space Network (DSN) Mark IV-A System is presented along with the design approach. The controllers are designed to enable the receiver-exciter subsystem (RCV) to be configured, calibrated, initialized and operated from a central location via high level instructions. The RECs are designed to be operated under the control of the DMC subsystem. The instructions are in the form of standard subsystem blocks (SSBs) received via the local area network (LAN). The centralized control provided by RECs and other DSCC controllers in Mark IV-A is intended to reduce DSN operations costs from the Mark III era.

  20. Quadratus Lumborum Block Versus Transversus Abdominis Plane Block for Postoperative Pain After Cesarean Delivery: A Randomized Controlled Trial.

    PubMed

    Blanco, Rafael; Ansari, Tarek; Riad, Waleed; Shetty, Nanda

    Effective postoperative analgesia after cesarean delivery enhances early recovery, ambulation, and breastfeeding. In a previous study, we established the effectiveness of the quadratus lumborum block in providing pain relief after cesarean delivery compared with patient-controlled analgesia (morphine). In the current study, we hypothesized that this method would be equal to or better than the transversus abdominis plane block with regard to pain relief and its duration of action after cesarean delivery. Between April 2015 and August 2015, we randomized 76 patients scheduled for elective cesarean delivery under spinal anesthesia to receive the quadratus lumborum block or the transversus abdominis plane block for postoperative pain relief. This trial was registered prospectively (NCT 02489851) [corrected]. Patients in the quadratus lumborum block group used significantly less morphine than the transversus abdominis plane block group (P < 0.05) at 12, 24, and 48 hours but not at 4 and 6 hours after cesarean delivery. This group also had significantly fewer morphine demands than the control group (P < 0.05) at 6, 12, 24, and 48 hours after cesarean delivery. No significant differences in visual analog scale results were shown between the 2 groups at rest or with movement. Calculated total pain relief at rest and with movement were similar (P < 0.001) in both groups. The quadratus lumborum block was more effective in reducing morphine consumption and demands than transversus abdominis plane blocks after cesarean section. This effect was observed up to 48 hours postoperatively.

  1. Welding Penetration Control of Fixed Pipe in TIG Welding Using Fuzzy Inference System

    NASA Astrophysics Data System (ADS)

    Baskoro, Ario Sunar; Kabutomori, Masashi; Suga, Yasuo

    This paper presents a study on welding penetration control of fixed pipe in Tungsten Inert Gas (TIG) welding using fuzzy inference system. The welding penetration control is essential to the production quality welds with a specified geometry. For pipe welding using constant arc current and welding speed, the bead width becomes wider as the circumferential welding of small diameter pipes progresses. Having welded pipe in fixed position, obviously, the excessive arc current yields burn through of metals; in contrary, insufficient arc current produces imperfect welding. In order to avoid these errors and to obtain the uniform weld bead over the entire circumference of the pipe, the welding conditions should be controlled as the welding proceeds. This research studies the intelligent welding process of aluminum alloy pipe 6063S-T5 in fixed position using the AC welding machine. The monitoring system used a charge-coupled device (CCD) camera to monitor backside image of molten pool. The captured image was processed to recognize the edge of molten pool by image processing algorithm. Simulation of welding control using fuzzy inference system was constructed to simulate the welding control process. The simulation result shows that fuzzy controller was suitable for controlling the welding speed and appropriate to be implemented into the welding system. A series of experiments was conducted to evaluate the performance of the fuzzy controller. The experimental results show the effectiveness of the control system that is confirmed by sound welds.

  2. High accuracy diffuse horizontal irradiance measurements without a shadowband

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schlemmer, J.A; Michalsky, J.J.

    1995-12-31

    The standard method for measuring diffuse horizontal irradiance uses a fixed shadowband to block direct solar radiation. This method requires a correction for the excess skylight blocked by the band, and this correction varies with sky conditions. Alternately, diffuse horizontal irradiance may be calculated from total horizontal and direct normal irradiance. This method is in error because of angular (cosine) response of the total horizontal pyranometer to direct beam irradiance. This paper describes an improved calculation of diffuse horizontal irradiance from total horizontal and direct normal irradiance using a predetermination of the angular response of the total horizontal pyranometer. Wemore » compare these diffuse horizontal irradiance calculations with measurements made with a shading-disk pyranometer that shields direct irradiance using a tracking disk. Results indicate significant improvement in most cases. Remaining disagreement most likely arises from undetected tracking errors and instrument leveling.« less

  3. High accuracy diffuse horizontal irradiance measurements without a shadowband

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schlemmer, J.A.; Michalsky, J.J.

    1995-10-01

    The standard method for measuring diffuse horizontal irradiance uses a fixed shadowband to block direct solar radiation. This method requires a correction for the excess skylight blocked by the band, and this correction varies with sky conditions. Alternately, diffuse horizontal irradiance may be calculated from the total horizontal and direct normal irradiance. This method is in error because of the angular (often referred to as cosine) response of the total horizontal pyranometer to direct beam irradiance. This paper describes an improved calculation of diffuse horizontal irradiance from total horizontal and direct normal irradiance using a predetermination of the angular responsemore » of the total horizontal pyranometer. The authors compare these diffuse horizontal irradiance calculations with measurements made with a shading-disk pyranometer that shields direct irradiance using a tracking disk. The results indicate significant improvement in most cases. The remaining disagreement most likely arises from undetected tracking errors and instrument leveling.« less

  4. Swimming invariant manifolds and the motion of bacteria in a fluid flow

    NASA Astrophysics Data System (ADS)

    Yoest, Helena; Mitchell, Kevin; Solomon, Tom

    2017-11-01

    We present experiments on the motion of both wild-type and smooth-swimming bacillus subtilis in a hyperbolic, microfluidic fluid flow. Passive invariant manifolds crossing the fixed point in the flow act as barriers that block inert tracers in the flow. Self-propelled tracers can cross these passive manifolds, but are blocked by and attracted to swimming invariant manifolds (SWIMs) that split from the passive manifolds with larger and larger non-dimensional swimming speed v0 ≡V0 / U , where V0 is the swimming speed in the absence of a flow and U is a characteristic flos speed. We present the theory that predicts these SWIMs for smooth-swimming tracers, along with experiments that we are conducting to test these theories. We also discuss potential effects of rheotaxis and chemotaxis on the phenomena. Supported by NSF Grant DMR-1361881.

  5. An Electron-Deficient Building Block Based on the B←N Unit: An Electron Acceptor for All-Polymer Solar Cells.

    PubMed

    Dou, Chuandong; Long, Xiaojing; Ding, Zicheng; Xie, Zhiyuan; Liu, Jun; Wang, Lixiang

    2016-01-22

    A double B←N bridged bipyridyl (BNBP) is a novel electron-deficient building block for polymer electron acceptors in all-polymer solar cells. The B←N bridging units endow BNBP with fixed planar configuration and low-lying LUMO/HOMO energy levels. As a result, the polymer based on BNBP units (P-BNBP-T) exhibits high electron mobility, low-lying LUMO/HOMO energy levels, and strong absorbance in the visible region, which is desirable for polymer electron acceptors. Preliminary all-polymer solar cell (all-PSC) devices with P-BNBP-T as the electron acceptor and PTB7 as the electron donor exhibit a power conversion efficiency (PCE) of 3.38%, which is among the highest values of all-PSCs with PTB7 as the electron donor. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Conformal Bootstrap in Mellin Space

    NASA Astrophysics Data System (ADS)

    Gopakumar, Rajesh; Kaviraj, Apratim; Sen, Kallol; Sinha, Aninda

    2017-02-01

    We propose a new approach towards analytically solving for the dynamical content of conformal field theories (CFTs) using the bootstrap philosophy. This combines the original bootstrap idea of Polyakov with the modern technology of the Mellin representation of CFT amplitudes. We employ exchange Witten diagrams with built-in crossing symmetry as our basic building blocks rather than the conventional conformal blocks in a particular channel. Demanding consistency with the operator product expansion (OPE) implies an infinite set of constraints on operator dimensions and OPE coefficients. We illustrate the power of this method in the ɛ expansion of the Wilson-Fisher fixed point by reproducing anomalous dimensions and, strikingly, obtaining OPE coefficients to higher orders in ɛ than currently available using other analytic techniques (including Feynman diagram calculations). Our results enable us to get a somewhat better agreement between certain observables in the 3D Ising model and the precise numerical values that have been recently obtained.

  7. Nanoporous Thermosets with Percolating Pores from Block Polymers Chemically Fixed above the Order–Disorder Transition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vidil, Thomas; Hampu, Nicholas; Hillmyer, Marc A.

    A lamellar diblock polymer combining a cross-linkable segment with a chemically etchable segment was cross-linked above its order–disorder temperature (TODT) to kinetically trap the morphology associated with the fluctuating disordered state. After removal of the etchable block, evaluation of the resulting porous thermoset allows for an unprecedented experimental characterization of the trapped disordered phase. Through a combination of small-angle X-ray scattering, nitrogen sorption, scanning electron microscopy, and electron tomography experiments we demonstrate that the nanoporous structure exhibits a narrow pore size distribution and a high surface to volume ratio and is bicontinuous over a large sample area. Together with themore » processability of the polymeric starting material, the proposed system combines attractive attributes for many advanced applications. In particular, it was used to design new composite membranes for the ultrafiltration of water.« less

  8. 49 CFR 236.401 - Automatic block signal system and interlocking standards applicable to traffic control systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Traffic Control Systems Standards § 236.401 Automatic... 49 Transportation 4 2011-10-01 2011-10-01 false Automatic block signal system and interlocking standards applicable to traffic control systems. 236.401 Section 236.401 Transportation Other Regulations...

  9. Optimized collectives using a DMA on a parallel computer

    DOEpatents

    Chen, Dong [Croton On Hudson, NY; Gabor, Dozsa [Ardsley, NY; Giampapa, Mark E [Irvington, NY; Heidelberger,; Phillip, [Cortlandt Manor, NY

    2011-02-08

    Optimizing collective operations using direct memory access controller on a parallel computer, in one aspect, may comprise establishing a byte counter associated with a direct memory access controller for each submessage in a message. The byte counter includes at least a base address of memory and a byte count associated with a submessage. A byte counter associated with a submessage is monitored to determine whether at least a block of data of the submessage has been received. The block of data has a predetermined size, for example, a number of bytes. The block is processed when the block has been fully received, for example, when the byte count indicates all bytes of the block have been received. The monitoring and processing may continue for all blocks in all submessages in the message.

  10. 33 CFR 127.201 - Sensing and alarm systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... systems. (a) Fixed sensors must have audio and visual alarms in the control room and audio alarms nearby. (b) Fixed sensors that continuously monitor for LNG vapors must— (1) Be in each enclosed area where vapor or gas may accumulate; and (2) Meet Section 9-4 of NFPA 59A. (c) Fixed sensors that continuously...

  11. 33 CFR 127.201 - Sensing and alarm systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... systems. (a) Fixed sensors must have audio and visual alarms in the control room and audio alarms nearby. (b) Fixed sensors that continuously monitor for LNG vapors must— (1) Be in each enclosed area where vapor or gas may accumulate; and (2) Meet Section 9-4 of NFPA 59A. (c) Fixed sensors that continuously...

  12. 33 CFR 127.201 - Sensing and alarm systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... systems. (a) Fixed sensors must have audio and visual alarms in the control room and audio alarms nearby. (b) Fixed sensors that continuously monitor for LNG vapors must— (1) Be in each enclosed area where vapor or gas may accumulate; and (2) Meet Section 9-4 of NFPA 59A. (c) Fixed sensors that continuously...

  13. 31 CFR 594.301 - Blocked account; blocked property.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Blocked account; blocked property. 594.301 Section 594.301 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY GLOBAL TERRORISM SANCTIONS...

  14. 31 CFR 545.301 - Blocked account; blocked property.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Blocked account; blocked property. 545.301 Section 545.301 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY TALIBAN (AFGHANISTAN) SANCTIONS...

  15. 31 CFR 551.301 - Blocked account; blocked property.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Blocked account; blocked property. 551.301 Section 551.301 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY SOMALIA SANCTIONS REGULATIONS...

  16. Kinetic control of block copolymer self-assembly into multicompartment and novel geometry nanoparticles

    NASA Astrophysics Data System (ADS)

    Chen, Yingchao; Wang, Xiaojun; Zhang, Ke; Wooley, Karen; Mays, Jimmy; Percec, Virgil; Pochan, Darrin

    2012-02-01

    Micelles with the segregation of hydrophobic blocks trapped in the same nanoparticle core have been produced through co-self-assembly of two block copolymers in THF/water dilute solution. The dissolution of two block copolymer sharing the same polyacrylic acid PAA blocks in THF undergoes consequent aggregation and phase separation through either slow water titration or quick water addition that triggers the micellar formation. The combination and comparison of the two water addition kinetic pathways are the keys of forming multicompartment structures at high water content. Importantly, the addition of organic diamine provides for acid-base complexation with the PAA side chains which, in turn, plays the key role of trapping unlike hydrophobic blocks from different block copolymers into one nanoparticle core. The kinetic control of solution assembly can be applied to other molecular systems such as dendrimers as well as other block copolymer molecules. Transmission electron microscopy, cryogenic transmission electron microscopy, light scattering have been applied to characterize the micelle structures.

  17. H2, fixed architecture, control design for large scale systems. Ph.D. Thesis

    NASA Technical Reports Server (NTRS)

    Mercadal, Mathieu

    1990-01-01

    The H2, fixed architecture, control problem is a classic linear quadratic Gaussian (LQG) problem whose solution is constrained to be a linear time invariant compensator with a decentralized processing structure. The compensator can be made of p independent subcontrollers, each of which has a fixed order and connects selected sensors to selected actuators. The H2, fixed architecture, control problem allows the design of simplified feedback systems needed to control large scale systems. Its solution becomes more complicated, however, as more constraints are introduced. This work derives the necessary conditions for optimality for the problem and studies their properties. It is found that the filter and control problems couple when the architecture constraints are introduced, and that the different subcontrollers must be coordinated in order to achieve global system performance. The problem requires the simultaneous solution of highly coupled matrix equations. The use of homotopy is investigated as a numerical tool, and its convergence properties studied. It is found that the general constrained problem may have multiple stabilizing solutions, and that these solutions may be local minima or saddle points for the quadratic cost. The nature of the solution is not invariant when the parameters of the system are changed. Bifurcations occur, and a solution may continuously transform into a nonstabilizing compensator. Using a modified homotopy procedure, fixed architecture compensators are derived for models of large flexible structures to help understand the properties of the constrained solutions and compare them to the corresponding unconstrained ones.

  18. Supersonic aerodynamic characteristics of a maneuvering canard-controlled missile with fixed and free-rolling tail fins

    NASA Technical Reports Server (NTRS)

    Blair, A. B., Jr.

    1990-01-01

    Wind tunnel investigations were conducted on a generic cruciform canard-controlled missile configuration. The model featured fixed or free-rolling tail-fin afterbodies to provide an expanded aerodynamic data base with particular emphasis on alleviating large induced rolling moments and/or for providing canard roll control throughout the entire test angle-of-attack range. The tests were conducted in the NASA Langley Unitary Plan Wind Tunnel at Mach numbers from 2.50 to 3.50 at a constant Reynolds number per foot of 2.00 x 10 to the 6th. Selected test results are presented to show the effects of a fixed or free-rolling tail-fin afterbody on the static longitudinal and lateral-directional aerodynamic characteristics of a canard-controlled missile with pitch, yaw, and roll control at model roll angles of 0 deg and 45 deg.

  19. Rewiring protein synthesis: From natural to synthetic amino acids.

    PubMed

    Fan, Yongqiang; Evans, Christopher R; Ling, Jiqiang

    2017-11-01

    The protein synthesis machinery uses 22 natural amino acids as building blocks that faithfully decode the genetic information. Such fidelity is controlled at multiple steps and can be compromised in nature and in the laboratory to rewire protein synthesis with natural and synthetic amino acids. This review summarizes the major quality control mechanisms during protein synthesis, including aminoacyl-tRNA synthetases, elongation factors, and the ribosome. We will discuss evolution and engineering of such components that allow incorporation of natural and synthetic amino acids at positions that deviate from the standard genetic code. The protein synthesis machinery is highly selective, yet not fixed, for the correct amino acids that match the mRNA codons. Ambiguous translation of a codon with multiple amino acids or complete reassignment of a codon with a synthetic amino acid diversifies the proteome. Expanding the genetic code with synthetic amino acids through rewiring protein synthesis has broad applications in synthetic biology and chemical biology. Biochemical, structural, and genetic studies of the translational quality control mechanisms are not only crucial to understand the physiological role of translational fidelity and evolution of the genetic code, but also enable us to better design biological parts to expand the proteomes of synthetic organisms. This article is part of a Special Issue entitled "Biochemistry of Synthetic Biology - Recent Developments" Guest Editor: Dr. Ilka Heinemann and Dr. Patrick O'Donoghue. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Flexible Fabrication of Shape-Controlled Collagen Building Blocks for Self-Assembly of 3D Microtissues.

    PubMed

    Zhang, Xu; Meng, Zhaoxu; Ma, Jingyun; Shi, Yang; Xu, Hui; Lykkemark, Simon; Qin, Jianhua

    2015-08-12

    Creating artificial tissue-like structures that possess the functionality, specificity, and architecture of native tissues remains a big challenge. A new and straightforward strategy for generating shape-controlled collagen building blocks with a well-defined architecture is presented, which can be used for self-assembly of complex 3D microtissues. Collagen blocks with tunable geometries are controllably produced and released via a membrane-templated microdevice. The formation of functional microtissues by embedding tissue-specific cells into collagen blocks with expression of specific proteins is described. The spontaneous self-assembly of cell-laden collagen blocks into organized tissue constructs with predetermined configurations is demonstrated, which are largely driven by the synergistic effects of cell-cell and cell-matrix interactions. This new strategy would open up new avenues for the study of tissue/organ morphogenesis, and tissue engineering applications. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Universal block diagram based modeling and simulation schemes for fractional-order control systems.

    PubMed

    Bai, Lu; Xue, Dingyü

    2017-05-08

    Universal block diagram based schemes are proposed for modeling and simulating the fractional-order control systems in this paper. A fractional operator block in Simulink is designed to evaluate the fractional-order derivative and integral. Based on the block, the fractional-order control systems with zero initial conditions can be modeled conveniently. For modeling the system with nonzero initial conditions, the auxiliary signal is constructed in the compensation scheme. Since the compensation scheme is very complicated, therefore the integrator chain scheme is further proposed to simplify the modeling procedures. The accuracy and effectiveness of the schemes are assessed in the examples, the computation results testify the block diagram scheme is efficient for all Caputo fractional-order ordinary differential equations (FODEs) of any complexity, including the implicit Caputo FODEs. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  2. Fixed functional appliances with multibracket appliances have no skeletal effect on the mandible: A systematic review and meta-analysis.

    PubMed

    Ishaq, Ramy Abdul Rahman; AlHammadi, Maged Sultan; Fayed, Mona M S; El-Ezz, Amr Abou; Mostafa, Yehya

    2016-05-01

    Our aim was to assess the skeletal mandibular changes (anteroposterior and vertical) in circumpubertal patients with fixed functional appliances installed on multibracket appliances compared with untreated patients. An open-ended electronic search of 4 databases (PubMed, Embase, Cochrane Library, and Web of Science) up to April 2014 was performed. Additional searches of relevant journals, reference lists of the retrieved articles, systematic reviews, and gray literature were performed. Specific inclusion and exclusion criteria were applied to identify relevant articles. Quality was evaluated using the Cochrane Collaboration risk of bias tool and the Newcastle-Ottawa scale for prospective controlled clinical trials. Meta-analyses were conducted with fixed and random effects models as appropriate. Statistical heterogeneity was also examined. Seven articles were included in the qualitative synthesis and 5 in the meta-analysis. The included randomized controlled trials were at high risk of bias, and the methodologic quality of the prospective controlled clinical trials was high. Based on assessment of the fixed functional appliance phase in isolation, no difference in mandibular anteroposterior positional changes (SNB angle) (standard mean difference, 0.11°; 95% CI, -0.28, 0.50) was found between the treated and control groups. The vertical dimension was not influenced by the fixed functional appliance treatment. There is little high-quality evidence concerning the relative influence of fixed functional appliances on skeletal and dentoalveolar changes. However, based on the limited evidence, it appears that they have little effect on the skeletal mandibular parameters. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  3. In Zucker Diabetic Fatty rats, subclinical diabetic neuropathy increases in vivo lidocaine block duration but not in vitro neurotoxicity

    PubMed Central

    Lirk, Philipp; Flatz, Magdalena; Haller, Ingrid; Hausott, Barbara; Blumenthal, Stephan; Stevens, Markus F.; Suzuki, Suzuko; Klimaschewski, Lars; Gerner, Peter

    2012-01-01

    Background and Objectives Application of local anesthetics may lead to nerve damage. Increasing evidence suggests that risk of neurotoxicity is higher in patients with diabetic peripheral neuropathy. Additionally, block duration may be prolonged in neuropathy. We sought to investigate neurotoxicity in vitro and block duration in vivo in a genetic animal model of diabetes mellitus type II. Methods In the first experiments, neurons harvested from control Zucker Diabetic Fatty (ZDF) rats were exposed to acute (24 hours) or chronic (72 hours) hyperglycemia, followed by incubation with lidocaine 40 mM (approximately 1%). In a second experiment, neurons harvested from control ZDF rats, or diabetic ZDF rats, were incubated with lidocaine, with or without SB203580, an inhibitor of the p38 Mitogen-Activated Protein Kinase. Finally, we performed sciatic nerve block (lidocaine 2%, 0.2 mL) in control or diabetic ZDF rats, and measured motor and nociceptive block duration. Results In vitro, neither acute nor chronic hyperglycemia altered neurotoxic properties of lidocaine. In vitro, incubation of neurons with lidocaine resulted in a slightly decreased survival ratio when neurons were harvested from diabetic (57 ± 19) as compared to control (64 ± 9 %) rats. The addition of SB203580 partly reversed this enhanced neurotoxic effect and raised survival to 71 ± 12 in diabetic and 66 ± 9 % in control rats, respectively. In vivo, even though no difference was detected at baseline testing, motor block was significantly prolonged in diabetic as compared to control rats (137 ± 16 min versus 86 ± 17 min). Conclusions In vitro, local anesthetic neurotoxicity was more pronounced on neurons from diabetic animals, but the survival difference was small. In vivo, subclinical neuropathy leads to substantial prolongation of block duration. We conclude that early diabetic neuropathy increases block duration, while the observed increase in toxicity was small. PMID:23011115

  4. Hemicellulose block copolymers made from woods for wide-range directed self-assembly lithography enabling wider range of applicable patterning size

    NASA Astrophysics Data System (ADS)

    Morita, Kazuyo; Yamamoto, Kimiko

    2017-03-01

    Xylan, one of hemicellulose family, block copolymer was newly developed for wide-range directed self-assembly lithography (DSA). Xylan is higher hydrophilic material because of having many hydroxy groups in one molecule. It means that xylan block copolymer has a possibility of high-chi block copolymer. Generally, DSA is focused on microphase separation for smaller size with high-chi block copolymer and not well known for larger size. In this study, xylan block copolymer was confirmed enabling wider range of patterning size, from smaller size to larger size. The key of xylan block copolymer is a new molecular structure of block copolymer and sugar chain control technology. Sugar content is the important parameter for not only micro-phase separation property but also line edge roughness (LER) and defects. Based on the sugar control technology, wide-range (hp 8.3nm to 26nm L/S and CD 10nm to 51nm hole) DSA patterning was demonstrated. Additionally it was confirmed that xylan block copolymer is suitable for sequential infiltration synthesis (SIS) process.

  5. Optimal strategies for the control of autonomous vehicles in data assimilation

    NASA Astrophysics Data System (ADS)

    McDougall, D.; Moore, R. O.

    2017-08-01

    We propose a method to compute optimal control paths for autonomous vehicles deployed for the purpose of inferring a velocity field. In addition to being advected by the flow, the vehicles are able to effect a fixed relative speed with arbitrary control over direction. It is this direction that is used as the basis for the locally optimal control algorithm presented here, with objective formed from the variance trace of the expected posterior distribution. We present results for linear flows near hyperbolic fixed points.

  6. 31 CFR 594.301 - Blocked account; blocked property.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false Blocked account; blocked property. 594.301 Section 594.301 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY GLOBAL TERRORISM SANCTIONS REGULATIONS...

  7. 31 CFR 594.301 - Blocked account; blocked property.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance:Treasury 3 2013-07-01 2013-07-01 false Blocked account; blocked property. 594.301 Section 594.301 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY GLOBAL TERRORISM SANCTIONS REGULATIONS...

  8. 31 CFR 594.301 - Blocked account; blocked property.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 31 Money and Finance:Treasury 3 2011-07-01 2011-07-01 false Blocked account; blocked property. 594.301 Section 594.301 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY GLOBAL TERRORISM SANCTIONS REGULATIONS...

  9. 49 CFR 236.804 - Signal, block.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Signal, block. 236.804 Section 236.804..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.804 Signal, block. A roadway signal operated either automatically or manually at the entrance to a block. ...

  10. 31 CFR 546.302 - Blocked account; blocked property.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Blocked account; blocked property. 546.302 Section 546.302 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY DARFUR SANCTIONS REGULATIONS General...

  11. 31 CFR 593.301 - Blocked account; blocked property.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Blocked account; blocked property. 593.301 Section 593.301 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY FORMER LIBERIAN REGIME OF CHARLES...

  12. 31 CFR 510.301 - Blocked account; blocked property.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false Blocked account; blocked property. 510.301 Section 510.301 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY NORTH KOREA SANCTIONS REGULATIONS General...

  13. 49 CFR 236.804 - Signal, block.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Signal, block. 236.804 Section 236.804..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.804 Signal, block. A roadway signal operated either automatically or manually at the entrance to a block. ...

  14. 49 CFR 236.804 - Signal, block.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Signal, block. 236.804 Section 236.804..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.804 Signal, block. A roadway signal operated either automatically or manually at the entrance to a block. ...

  15. 49 CFR 236.804 - Signal, block.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Signal, block. 236.804 Section 236.804..., MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.804 Signal, block. A roadway signal operated either automatically or manually at the entrance to a block. ...

  16. 31 CFR 547.302 - Blocked account; blocked property.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Blocked account; blocked property. 547.302 Section 547.302 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY DEMOCRATIC REPUBLIC OF THE CONGO...

  17. The efficacy of conventional radiofrequency denervation in patients with chronic low back pain originating from the facet joints: a meta-analysis of randomized controlled trials.

    PubMed

    Lee, Chang-Hyun; Chung, Chun Kee; Kim, Chi Heon

    2017-11-01

    Radiofrequency denervation is commonly used for the treatment of chronic facet joint pain that has been refractory to more conservative treatments, although the evidence supporting this treatment has been controversial. We aimed to elucidate the precise effects of radiofrequency denervation in patients with low back pain originating from the facet joints relative to those obtained using control treatments, with particular attention to consistency in the denervation protocol. A meta-analysis of randomized controlled trials was carried out. Adult patients undergoing radiofrequency denervation or control treatments (sham or epidural block) for facet joint disease of the lumbar spine comprised the patient sample. Visual analog scale (VAS) pain scores were measured and stratified by response of diagnostic block procedures. We searched PubMed, Embase, Web of Science, and the Cochrane Database for randomized controlled trials regarding radiofrequency denervation and control treatments for back pain. Changes in VAS pain scores of the radiofrequency group were compared with those of the control group as well as the minimal clinically important difference (MCID) for back pain VAS. Meta-regression model was developed to evaluate the effect of radiofrequency treatment according to responses of diagnostic block while controlling for other variables. We then calculated mean differences and 95% confidence intervals (CIs) using random-effects models. We included data from seven trials involving 454 patients who had undergone radiofrequency denervation (231 patients) and control treatments such as sham or epidural block procedures (223 patients). The radiofrequency group exhibited significantly greater improvements in back pain score when compared with the control group for 1-year follow-up. Although the average improvement in VAS scores exceeded the MCID, the lower limit of the 95% CI encompassed the MCID. A subgroup of patients who responded very well to diagnostic block procedures demonstrated significant improvements in back pain relative to the control group at all times. When placed into our meta-regression model, the response to diagnostic block procedure was responsible for a statistically significant portion of treatment effect. Studies published over the last two decades revealed that radiofrequency denervation reduced back pain significantly in patients with facet joint disease compared with the MCID and control treatments. Conventional radiofrequency denervation resulted in significant reductions in low back pain originating from the facet joints in patients showing the best response to diagnostic block over the first 12 months when compared with sham procedures or epidural nerve blocks. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Postoperative Analgesic Efficacy of Bilateral Transversus Abdominis Plane Block in Patients Undergoing Midline Colorectal Surgeries Using Ropivacaine: A Randomized, Double-blind, Placebo-controlled Trial.

    PubMed

    Qazi, Nahida; Bhat, Wasim Mohammad; Iqbal, Malik Zaffar; Wani, Anisur Rehman; Gurcoo, Showkat A; Rasool, Sahir

    2017-01-01

    Ultrasound-guided transversus abdominis plane (TAP) block is done as a part of multimodal analgesia for pain relief after abdominal surgeries. This prospective randomized, double-blind, placebo-controlled trial was conducted to evaluate the postoperative analgesic efficacy of bilateral TAP block in patients undergoing midline colorectal surgeries using ropivacaine. Eighty patients scheduled for elective colorectal surgeries involving midline abdominal wall incision under general anesthesia were enrolled in this prospective randomized controlled trial. Group A received TAP block with 20 ml of 0.2% ropivacaine on either side of the abdominal wall, and Group B received 20 ml of normal saline. The time to request for rescue analgesia, total analgesic consumption in 24 h, and satisfaction with the anesthetic technique were assessed. The mean visual analog scale scores at rest and on coughing were higher in control group ( P > 0.05). Time (min) to request for the first rescue analgesia was prolonged in study group compared to control group ( P < 0.001). The total tramadol consumption in 24 h postoperatively was significantly high in control group ( P < 0.001). Nausea/vomiting was more common in control group ( P > 0.05). The level of satisfaction concerning postoperative pain control/anesthetic technique was higher in study group ( P < 0.001). TAP block produces effective and prolonged postoperative analgesia in patients undergoing midline colorectal surgery. It is a technically simple block to perform with a high margin of safety. It produces a considerable reduction in mean intravenous postoperative tramadol requirements, reduction in postoperative pain scores, and increased time to first request for further analgesia, both at rest and on movement.

  19. Postoperative Analgesic Efficacy of Bilateral Transversus Abdominis Plane Block in Patients Undergoing Midline Colorectal Surgeries Using Ropivacaine: A Randomized, Double-blind, Placebo-controlled Trial

    PubMed Central

    Qazi, Nahida; Bhat, Wasim Mohammad; Iqbal, Malik Zaffar; Wani, Anisur Rehman; Gurcoo, Showkat A.; Rasool, Sahir

    2017-01-01

    Background: Ultrasound-guided transversus abdominis plane (TAP) block is done as a part of multimodal analgesia for pain relief after abdominal surgeries. This prospective randomized, double-blind, placebo-controlled trial was conducted to evaluate the postoperative analgesic efficacy of bilateral TAP block in patients undergoing midline colorectal surgeries using ropivacaine. Materials and Methods: Eighty patients scheduled for elective colorectal surgeries involving midline abdominal wall incision under general anesthesia were enrolled in this prospective randomized controlled trial. Group A received TAP block with 20 ml of 0.2% ropivacaine on either side of the abdominal wall, and Group B received 20 ml of normal saline. The time to request for rescue analgesia, total analgesic consumption in 24 h, and satisfaction with the anesthetic technique were assessed. Results: The mean visual analog scale scores at rest and on coughing were higher in control group (P > 0.05). Time (min) to request for the first rescue analgesia was prolonged in study group compared to control group (P < 0.001). The total tramadol consumption in 24 h postoperatively was significantly high in control group (P < 0.001). Nausea/vomiting was more common in control group (P > 0.05). The level of satisfaction concerning postoperative pain control/anesthetic technique was higher in study group (P < 0.001). Conclusion: TAP block produces effective and prolonged postoperative analgesia in patients undergoing midline colorectal surgery. It is a technically simple block to perform with a high margin of safety. It produces a considerable reduction in mean intravenous postoperative tramadol requirements, reduction in postoperative pain scores, and increased time to first request for further analgesia, both at rest and on movement. PMID:28928585

  20. 75 FR 26889 - Airworthiness Directives; Arrow Falcon Exporters, Inc. (previously Utah State University) et al...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-13

    ... the forward tip weight retention block (tip block) or aft tip closure (tip closure), loss of the blade...) forward tip weight retention block (tip block) and the aft tip closure (tip closure) for adhesive bond... prevent loss of a tip block or tip closure, loss of a blade, and subsequent loss of control of the...

  1. Detection of combustion start in the controlled auto ignition engine by wavelet transform of the engine block vibration signal

    NASA Astrophysics Data System (ADS)

    Kim, Seonguk; Min, Kyoungdoug

    2008-08-01

    The CAI (controlled auto ignition) engine ignites fuel and air mixture by trapping high temperature burnt gas using a negative valve overlap. Due to auto ignition in CAI combustion, efficiency improvements and low level NOx emission can be obtained. Meanwhile, the CAI combustion regime is restricted and control parameters are limited. The start of combustion data in the compressed ignition engine are most critical for controlling the overall combustion. In this research, the engine block vibration signal is transformed by the Meyer wavelet to analyze CAI combustion more easily and accurately. Signal acquisition of the engine block vibration is a more suitable method for practical use than measurement of in-cylinder pressure. A new method for detecting combustion start in CAI engines through wavelet transformation of the engine block vibration signal was developed and results indicate that it is accurate enough to analyze the start of combustion. Experimental results show that wavelet transformation of engine block vibration can track the start of combustion in each cycle. From this newly developed method, the start of combustion data in CAI engines can be detected more easily and used as input data for controlling CAI combustion.

  2. Fixed-Time Outer Synchronization of Complex Networks with Noise Coupling

    NASA Astrophysics Data System (ADS)

    Shi, Hong-Jun; Miao, Lian-Ying; Sun, Yong-Zheng; Liu, Mao-Xing

    2018-03-01

    In this paper, the fixed-time outer synchronization of complex networks with noise coupling is investigated. Based on the theory of fixed-time stability and matrix inequalities, sufficient conditions for fixed-time outer synchronization are established and the estimation of the upper bound of the setting time is obtained. The result shows that the setting time can be adjusted to a desired value regardless of the initial states. Numerical simulations are performed to verify the effectiveness of the theoretical results. The effects of control parameters and the density of controlled nodes on the converging time are studied. Supported by the National Natural Science Foundation of China under Grant Nos. 11711530203 and 11771443, and the Fundamental Research Funds for the Central Universities under Grant No. 2015XKMS076

  3. Implant-supported restoration of congenitally missing teeth using cancellous bone block-allografts.

    PubMed

    Nissan, Joseph; Mardinger, Ofer; Strauss, Morris; Peleg, Michael; Sacco, Roberto; Chaushu, Gavriel

    2011-03-01

    Patients with congenitally missing teeth may present with undeveloped alveolar bone morphology, making implant reconstruction a challenge. The aim of the present study was to evaluate the outcome of dental implants after ridge augmentation with cancellous freeze-dried block bone allografts in patients with congenitally missing teeth. Twelve patients with a mean age of 21 ± 4 years, were included. Congenitally missing teeth included maxillary lateral incisors, a maxillary canine, and mandibular central and lateral incisors. A bony deficiency of ≥3 mm horizontally and ≤3 mm vertically according to computerized tomography served as inclusion criteria. Twenty-one implants were inserted after a healing period of 6 months. Five out of 21 implants were immediately restored. Bone measurements were taken before bone augmentation, during implant placement, and at second-stage surgery. Nineteen cancellous allogeneic bone-blocks were used. The mean follow-up time was 30 ± 16 months. Bone block and implant survival rates were 100% and 95.2%, respectively. Mean bone gain was statistically significant (P < .001): 5 ± 0.5 mm horizontally and 2 ± 0.5 mm vertically. All of the patients received a fixed implant-supported prosthesis. Soft tissue complications occurred in 4 patients (30%). Complications after cementation of the crowns were seen in 1 implant (4.8%). All implants remained clinically osseointegrated at the end of the follow-up examination. There was no crestal bone loss around the implants beyond the first implant thread. Cancellous bone block-allografts can be used successfully for implant-supported restorations in patients with congenitally missing teeth. Copyright © 2011 Mosby, Inc. All rights reserved.

  4. Efficacy of cancellous block allograft augmentation prior to implant placement in the posterior atrophic mandible.

    PubMed

    Nissan, Joseph; Ghelfan, Oded; Mardinger, Ofer; Calderon, Shlomo; Chaushu, Gavriel

    2011-12-01

    The present study evaluated the outcome of ridge augmentation with cancellous freeze-dried block bone allografts in the posterior atrophic mandible followed by placement of dental implants. A bony deficiency of at least 3 mm, horizontally, vertically, or both, according to computerized tomography (CT) para-axial reconstruction served as inclusion criteria. Implants were inserted after a healing period of 6 months. Bone measurements were taken prior to bone augmentation, during implant placement, and at second-stage surgery. Marginal bone loss and crown-to-implant ratio were also measured. Twenty-nine cancellous allogeneic bone blocks were placed in 21 patients. The mean follow-up was 37 months. Bone block survival rate was 79.3%. Mean horizontal and vertical bone gains were 5.6 and 4.3 mm, respectively. Mean buccal bone resorption was 0.5 mm at implant placement and 0.2 mm at second-stage surgery. A total of 85 implants were placed. Mean bone thickness buccal to the implant neck was 2.5 mm at implant placement and 2.3 mm at second-stage surgery. There was no evidence of vertical bone loss between implant placement and second-stage surgery. Implant survival rate was 95.3%. All patients received a fixed implant-supported prosthesis. At the last follow-up, the mean marginal bone loss was 0.5 mm. The mean crown-to-implant ratio was 0.96. Implant placement in the posterior atrophic mandible following augmentation with cancellous freeze-dried bone block allografts may be regarded as a viable treatment alternative. © 2009 Wiley Periodicals, Inc.

  5. Cancellous bone block allografts for the augmentation of the anterior atrophic maxilla.

    PubMed

    Nissan, Joseph; Mardinger, Ofer; Calderon, Shlomo; Romanos, George E; Chaushu, Gavriel

    2011-06-01

    Pre-implant augmentative surgery is a prerequisite in many cases in the anterior maxilla to achieve a stable, long-term esthetic final result. The aim of the present study was to evaluate the outcome of ridge augmentation with cancellous freeze-dried block bone allografts in the anterior atrophic maxilla followed by placement of dental implants. Thirty-one consecutive patients were included in the study. A bony deficiency of at least 3 mm horizontally and up to 3 mm vertically according to computerized tomography (CT) served as inclusion criteria. Sixty-three implants were inserted after a healing period of 6 months. Nineteen of sixty-three implants were immediately restored. Bone measurements were taken prior to bone augmentation, during implant placement, and at second-stage surgery. Forty-six cancellous allogeneic bone blocks were used. The mean follow-up was 34 ± 16 months. Mean bone gain was 5 ± 0.5 mm horizontally, and 2 ± 0.5 mm vertically. Mean buccal bone resorption was 0.5 ± 0.5 mm at implant placement, and 0.2 ± 0.2 mm at second-stage surgery. Mean bone thickness buccal to the implant neck was 2.5 ± 0.5 mm at implant placement, and 2.3 ± 0.2 mm at second-stage surgery. There was no evidence of vertical bone loss between implant placement and second-stage surgery. Block and implant survival rates were 95.6 and 98%, respectively. All patients received a fixed implant-supported prosthesis. Cancellous block allografts appear to hold promise for grafting the anterior atrophic maxilla. © 2009 Wiley Periodicals, Inc.

  6. Free-time and fixed end-point optimal control theory in dissipative media: application to entanglement generation and maintenance.

    PubMed

    Mishima, K; Yamashita, K

    2009-07-07

    We develop monotonically convergent free-time and fixed end-point optimal control theory (OCT) in the density-matrix representation to deal with quantum systems showing dissipation. Our theory is more general and flexible for tailoring optimal laser pulses in order to control quantum dynamics with dissipation than the conventional fixed-time and fixed end-point OCT in that the optimal temporal duration of laser pulses can also be optimized exactly. To show the usefulness of our theory, it is applied to the generation and maintenance of the vibrational entanglement of carbon monoxide adsorbed on the copper (100) surface, CO/Cu(100). We demonstrate the numerical results and clarify how to combat vibrational decoherence as much as possible by the tailored shapes of the optimal laser pulses. It is expected that our theory will be general enough to be applied to a variety of dissipative quantum dynamics systems because the decoherence is one of the quantum phenomena sensitive to the temporal duration of the quantum dynamics.

  7. Support and maneuvering device

    DOEpatents

    Wood, R.L.

    1987-03-23

    A support and maneuvering device includes an elongated flexible inflatable enclosure having a fixed end and a movable end. The movable end is collapsible toward the fixed end to a contracted position when the enclosure is in a noninflated condition. Upon inflation, the movable end is movable away from the fixed end to an extended position. The movable end includes means for mounting an article such as a solar reflector thereon. The device also includes a plurality of position controlling means disposed about the movable end to effect adjusting movement of portions thereof by predetermined amounts and for controlling an angle at which the article disposed at the movable end is oriented. The plurality of position controlling means limits a suitable number degrees of freedom of the movable end for transmitting a steering motion thereto and for controlling the position thereof. 9 figs.

  8. Support and maneuvering device

    DOEpatents

    Wood, Richard L.

    1988-01-01

    A support and maneuvering device includes an elongated flexible inflatable enclosure having a fixed end and a movable end. The movable end is collapsible toward the fixed end to a contracted position when the enclosure is in a noninflated condition. Upon inflation, the movable end is movable away from the fixed end to an extended position. The movable end includes means for mounting an article such as a solar reflector thereon. The device also includes a plurality of position controlling means disposed about the movable end to effect adjusting movement of portions thereof by predetermined amounts and for controlling an angle at which the article disposed at the movable end is oriented. The plurality of position controlling means limits a suitable number degrees of freedom of the movable end for transmitting a steering motion thereto and for controlling the position thereof.

  9. Shape Recovery with Concomitant Mechanical Strengthening of Amphiphilic Shape Memory Polymers in Warm Water

    DOE PAGES

    Zhang, Ben; DeBartolo, Janae E.; Song, Jie

    2017-01-26

    Maintaining adequate or enhancing mechanical properties of shape memory polymers (SMPs) after shape recovery in an aqueous environment are greatly desired for biomedical applications of SMPs as self-fitting tissue scaffolds or minimally invasive surgical implants. Here we report stable temporary shape fixing and facile shape recovery of biodegradable triblock amphiphilic SMPs containing a poly(ethylene glycol) (PEG) center block and flanking poly(lactic acid) or poly(lactic-co-glycolic acid) blocks in warm water, accompanied with concomitant enhanced mechanical strengths. Differential scanning calorimetry (DSC), wide-angle X-ray diffraction (WXRD) and small-angle X-ray scattering (SAXS) analyses revealed that the unique stiffening of the amphiphilic SMPs upon hydrationmore » was due to hydration-driven microphase separation and PEG crystallization. We further demonstrated that the chemical composition of degradable blocks in these SMPs could be tailored to affect the persistence of hydration-induced stiffening upon subsequent dehydration. These properties combined open new horizons for these amphiphilic SMPs for smart weight-bearing in vivo applications (e.g. as self-fitting intervertebral discs). In conclusion, this study also provides a new material design strategy to strengthen polymers in aqueous environment in general.« less

  10. 49 CFR 236.504 - Operation interconnected with automatic block-signal system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Operation interconnected with automatic block... Operation interconnected with automatic block-signal system. (a) A continuous inductive automatic train stop or train control system shall operate in connection with an automatic block signal system and shall...

  11. 49 CFR 236.708 - Block.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Block. 236.708 Section 236.708 Transportation... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.708 Block. A length of track of defined limits, the use of which by trains is governed by block signals, cab signals, or both. ...

  12. 31 CFR 593.301 - Blocked account; blocked property.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 31 Money and Finance:Treasury 3 2011-07-01 2011-07-01 false Blocked account; blocked property. 593.301 Section 593.301 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY FORMER LIBERIAN REGIME OF CHARLES TAYLOR...

  13. 31 CFR 593.301 - Blocked account; blocked property.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false Blocked account; blocked property. 593.301 Section 593.301 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY FORMER LIBERIAN REGIME OF CHARLES TAYLOR...

  14. 31 CFR 593.301 - Blocked account; blocked property.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance:Treasury 3 2013-07-01 2013-07-01 false Blocked account; blocked property. 593.301 Section 593.301 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY FORMER LIBERIAN REGIME OF CHARLES TAYLOR...

  15. 31 CFR 593.301 - Blocked account; blocked property.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 31 Money and Finance:Treasury 3 2014-07-01 2014-07-01 false Blocked account; blocked property. 593.301 Section 593.301 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY FORMER LIBERIAN REGIME OF CHARLES TAYLOR...

  16. 31 CFR 547.302 - Blocked account; blocked property.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 31 Money and Finance:Treasury 3 2014-07-01 2014-07-01 false Blocked account; blocked property. 547.302 Section 547.302 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY DEMOCRATIC REPUBLIC OF THE CONGO SANCTIONS...

  17. 31 CFR 547.302 - Blocked account; blocked property.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance:Treasury 3 2012-07-01 2012-07-01 false Blocked account; blocked property. 547.302 Section 547.302 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY DEMOCRATIC REPUBLIC OF THE CONGO SANCTIONS...

  18. 31 CFR 547.302 - Blocked account; blocked property.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 31 Money and Finance:Treasury 3 2011-07-01 2011-07-01 false Blocked account; blocked property. 547.302 Section 547.302 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY DEMOCRATIC REPUBLIC OF THE CONGO SANCTIONS...

  19. 31 CFR 547.302 - Blocked account; blocked property.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance:Treasury 3 2013-07-01 2013-07-01 false Blocked account; blocked property. 547.302 Section 547.302 Money and Finance: Treasury Regulations Relating to Money and Finance (Continued) OFFICE OF FOREIGN ASSETS CONTROL, DEPARTMENT OF THE TREASURY DEMOCRATIC REPUBLIC OF THE CONGO SANCTIONS...

  20. 47 CFR 90.475 - Operation of internal transmitter control systems in specially equipped systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... systems involving fixed systems whose base stations are controlled by such systems may automatically access these base stations through the microwave or operational fixed systems from positions in the PSTN, so long as the base stations and mobile units meet the requirements of § 90.483 and if a separate...

  1. 49 CFR 236.504 - Operation interconnected with automatic block-signal system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... GOVERNING THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Standards § 236.504... or train control system shall operate in connection with an automatic block signal system and shall...

  2. Research in robust control for hypersonic aircraft

    NASA Technical Reports Server (NTRS)

    Calise, A. J.

    1994-01-01

    The research during the third reporting period focused on fixed order robust control design for hypersonic vehicles. A new technique was developed to synthesize fixed order H(sub infinity) controllers. A controller canonical form is imposed on the compensator structure and a homotopy algorithm is employed to perform the controller design. Various reduced order controllers are designed for a simplified version of the hypersonic vehicle model used in our previous studies to demonstrate the capabilities of the code. However, further work is needed to investigate the issue of numerical ill-conditioning for large order systems and to make the numerical approach more reliable.

  3. High-efficiency holograms fixed in lithium niobate after recording using a digital fringe stabilization system.

    PubMed

    Arizmendi, Luis; Ambite, Emilio J

    2012-02-20

    We used a digital feedback control loop system to produce reproducible fixed volume transmission holograms of high diffraction efficiency. Different strategies were investigated to obtain holograms of good quality and the highest refractive index modulation depth. Using this control system, we were able to record holograms with stationary fringes. Additionally to using the stationary fringe recording, a double recording-fixing schedule resulted in being the most appropriate one to produce reproducible holograms of better characteristics. This strategy is discussed and compared with other already established ones. © 2012 Optical Society of America

  4. Sedation-analgesia with propofol and remifentanil: concentrations required to avoid gag reflex in upper gastrointestinal endoscopy.

    PubMed

    Borrat, Xavier; Valencia, José Fernando; Magrans, Rudys; Gimenez-Mila, Marc; Mellado, Ricard; Sendino, Oriol; Perez, Maria; Nunez, Matilde; Jospin, Mathieu; Jensen, Erik Weber; Troconiz, Inaki; Gambus, Pedro L

    2015-07-01

    The purpose of this study was to identify optimal target propofol and remifentanil concentrations to avoid a gag reflex in response to insertion of an upper gastrointestinal endoscope. Patients presenting for endoscopy received target-controlled infusions (TCI) of both propofol and remifentanil for sedation-analgesia. Patients were randomized to 4 groups of fixed target effect-site concentrations: remifentanil 1 ng•mL (REMI 1) or 2 ng•mL (REMI 2) and propofol 2 μg•mL (PROP 2) or 3 μg•mL (PROP 3). For each group, the other drug (propofol for the REMI groups and vice versa) was increased or decreased using the "up-down" method based on the presence or absence of a gag response in the previous patient. A modified isotonic regression method was used to estimate the median effective Ce,50 from the up-down method in each group. A concentration-effect (sigmoid Emax) model was built to estimate the corresponding Ce,90 for each group. These data were used to estimate propofol bolus doses and remifentanil infusion rates that would achieve effect-site concentrations between Ce,50 and Ce,90 when a TCI system is not available for use. One hundred twenty-four patients were analyzed. To achieve between a 50% and 90% probability of no gag response, propofol TCIs were between 2.40 and 4.23 μg•mL (that could be achieved with a bolus of 1 mg•kg) when remifentanil TCI was fixed at 1 ng•mL, and target propofol TCIs were between 2.15 and 2.88 μg•mL (that could be achieved with a bolus of 0.75 mg•kg) when remifentanil TCI was fixed at 2 ng•mL. Remifentanil ranges were 1.00 to 4.79 ng•mL and 0.72 to 3.19 ng•mL when propofol was fixed at 2 and 3 μg•mL, respectively. We identified a set of propofol and remifentanil TCIs that blocked the gag response to endoscope insertion in patients undergoing endoscopy. Propofol bolus doses and remifentanil infusion rates designed to achieve similar effect-site concentrations can be used to prevent gag response when TCI is not available.

  5. [Microanalytical determinations of gold alloys for fixed dentures].

    PubMed

    Lotito, M; Negri, P; Fraschini, M

    1993-01-01

    In this work the authors analyse gold alloys for fixed prosthesis by X-ray spectrometry in energy dispersion (EDS). The results of this analysis, given in graphic and table form, show remarkable differences in alloy composition. For this reason recommended dentists are to be attentive and severe in the control of gold alloys for fixed prosthesis.

  6. Liposomal bupivacaine versus interscalene nerve block for pain control after shoulder arthroplasty: A meta-analysis.

    PubMed

    Yan, Zeng; Chen, Zong; Ma, Chuangen

    2017-07-01

    Postoperative pain control after total shoulder arthroplasty (TSA) can be challenging. Liposomal bupivacaine and interscalene nerve block are 2 common pain control protocol for TSA patients. However, whether liposomal bupivacaine was superior than interscalene nerve block was unknown. This meta-analysis aimed to illustrate the efficacy liposomal bupivacaine versus interscalene nerve block for pain control in patients undergoing TSA. In May 2017, a systematic computer-based search was conducted in PubMed, EMBASE, Web of Science, Cochrane Database of Systematic Reviews, and Google database. Data on patients prepared for TSA in studies that compared liposomal bupivacaine versus interscalene nerve block were retrieved. The endpoints were the visual analogue scale (VAS) at 4 hours, 8 hours, 12 hours, 24 hours, and 2 weeks, total morphine consumption at 24 hours, and the length of hospital stay. Software of Stata 12.0 was used for pooling the final outcomes. Five clinical studies with 573 patients (liposomal bupivacaine group = 239, interscalene nerve block group = 334) were ultimately included in the meta-analysis. There was no significant difference between the VAS at 4 hours, 8 hours, and 2 weeks between liposomal bupivacaine group and interscalene nerve block group (P > .05). Compared with interscalene nerve block group, liposomal bupivacaine was associated with a reduction of VAS score at 12 hours, 24 hours by appropriately 3.31 points and 6.42 points respectively on a 100-point VAS. Furthermore, liposomal bupivacaine was associated with a significantly reduction of the length of hospital stay by appropriately by 0.16 days compared with interscalene nerve block group. Current meta-analysis indicates that compared with interscalene nerve block, liposomal bupivacaine had comparative effectiveness on reducing both pain scores and the length of hospital stay. However, studies with more patients and better-designed methods are needed to establish the optimal regimen and the safety of liposomal bupivacaine in TSA patients.

  7. Liposomal bupivacaine versus interscalene nerve block for pain control after shoulder arthroplasty

    PubMed Central

    Yan, Zeng; Chen, Zong; Ma, Chuangen

    2017-01-01

    Abstract Background: Postoperative pain control after total shoulder arthroplasty (TSA) can be challenging. Liposomal bupivacaine and interscalene nerve block are 2 common pain control protocol for TSA patients. However, whether liposomal bupivacaine was superior than interscalene nerve block was unknown. This meta-analysis aimed to illustrate the efficacy liposomal bupivacaine versus interscalene nerve block for pain control in patients undergoing TSA. Methods: In May 2017, a systematic computer-based search was conducted in PubMed, EMBASE, Web of Science, Cochrane Database of Systematic Reviews, and Google database. Data on patients prepared for TSA in studies that compared liposomal bupivacaine versus interscalene nerve block were retrieved. The endpoints were the visual analogue scale (VAS) at 4 hours, 8 hours, 12 hours, 24 hours, and 2 weeks, total morphine consumption at 24 hours, and the length of hospital stay. Software of Stata 12.0 was used for pooling the final outcomes. Results: Five clinical studies with 573 patients (liposomal bupivacaine group = 239, interscalene nerve block group = 334) were ultimately included in the meta-analysis. There was no significant difference between the VAS at 4 hours, 8 hours, and 2 weeks between liposomal bupivacaine group and interscalene nerve block group (P > .05). Compared with interscalene nerve block group, liposomal bupivacaine was associated with a reduction of VAS score at 12 hours, 24 hours by appropriately 3.31 points and 6.42 points respectively on a 100-point VAS. Furthermore, liposomal bupivacaine was associated with a significantly reduction of the length of hospital stay by appropriately by 0.16 days compared with interscalene nerve block group. Conclusion: Current meta-analysis indicates that compared with interscalene nerve block, liposomal bupivacaine had comparative effectiveness on reducing both pain scores and the length of hospital stay. However, studies with more patients and better-designed methods are needed to establish the optimal regimen and the safety of liposomal bupivacaine in TSA patients. PMID:28682872

  8. Increased impulsive action in rats: effects of morphine in a short and long fixed-delay response inhibition task.

    PubMed

    Mahoney, Megan K; Silveira, Mason M; Olmstead, Mary C

    2013-12-01

    Impulsive action is mediated through several neurochemical systems, although it is not clear which role each of these plays in the inability to withhold inappropriate responses. Manipulations of the opioid system alter impulsive action in rodents, although the effects are not consistent across tasks. Previously, we speculated that these discrepancies reflect differences in the cognitive mechanisms that control responding in each task. We investigated whether the effect of morphine, a mu opioid receptor (MOR) agonist, on impulsive action depends on the ability of the subjects to time the interval during which they must inhibit a response. Male Long-Evans rats were trained in a response inhibition (RI) task to withhold responding for sucrose during a 4- or 60-s delay; impulsive action was assessed as increased responding during the delay. The rats were tested following an injection of morphine (0, 1, 3, 6 mg/kg). In a subsequent experiment, the effects of morphine (6 mg/kg) plus the MOR antagonist naloxone (0, 0.3, 1, 3 mg/kg) were investigated. Morphine increased impulsive action, but had different effects in the two conditions: the drug increased the proportion of premature responses as the 4-s interval progressed and produced a general increase in responding across the 60-s interval. Naloxone blocked all morphine-induced effects. The finding that morphine increases impulsive action in a fixed-delay RI task contrasts with our previous evidence which shows no effect in the same task with a variable delay. Thus, MORs disrupt impulsive action only when rats can predict the delay to respond.

  9. Fixed weight Hopfield Neural Network based on optical implementation of all-optical MZI-XNOR logic gate

    NASA Astrophysics Data System (ADS)

    Nugamesh Mutter, Kussay; Mat Jafri, Mohd Zubir; Abdul Aziz, Azlan

    2010-05-01

    Many researches are conducted to improve Hopfield Neural Network (HNN) performance especially for speed and memory capacity in different approaches. However, there is still a significant scope of developing HNN using Optical Logic Gates. We propose here a new model of HNN based on all-optical XNOR logic gates for real time color image recognition. Firstly, we improved HNN toward optimum learning and converging operations. We considered each unipolar image as a set of small blocks of 3-pixels as vectors for HNN. This enables to save large number of images in the net with best reaching into global minima, and because there are only eight fixed states of weights so that only single iteration performed to construct a vector with stable state at minimum energy. HNN is useless in dealing with data not in bipolar representation. Therefore, HNN failed to work with color images. In RGB bands each represents different values of brightness, for d-bit RGB image it is simply consists of d-layers of unipolar. Each layer is as a single unipolar image for HNN. In addition, the weight matrices with stability of unity at the diagonal perform clear converging in comparison with no self-connecting architecture. Synchronously, each matrix-matrix multiplication operation would run optically in the second part, since we propose an array of all-optical XOR gates, which uses Mach-Zehnder Interferometer (MZI) for neurons setup and a controlling system to distribute timely signals with inverting to achieve XNOR function. The primary operation and simulation of the proposal HNN is demonstrated.

  10. Comparison of ultrasound-guided posterior transversus abdominis plane block and lateral transversus abdominis plane block for postoperative pain management in patients undergoing cesarean section: a randomized double-blind clinical trial study.

    PubMed

    Faiz, Seyed Hamid Reza; Alebouyeh, Mahmoud Reza; Derakhshan, Pooya; Imani, Farnad; Rahimzadeh, Poupak; Ghaderi Ashtiani, Maryam

    2018-01-01

    Due to the importance of pain control after abdominal surgery, several methods such as transversus abdominis plane (TAP) block are used to reduce the pain after surgery. TAP blocks can be performed using various ultrasound-guided approaches. Two important approaches to do this are ultrasound-guided lateral and posterior approaches. This study aimed to compare the two approaches of ultrasound-guided lateral and posterior TAP blocks to control pain after cesarean section. In this double-blind clinical trial study, 76 patients scheduled for elective cesarean section were selected and randomly divided into two groups of 38 and underwent spinal anesthesia. For pain management after the surgery, one group underwent lateral TAP block and the other group underwent posterior TAP block using 20cc of ropivacaine 0.2% on both sides. Pain intensity was evaluated based on Numerical Analog Scale (NAS) at rest and when coughing, 2, 4, 6, 12, 24 and 36 hours after surgery. The pain at rest in the posterior group at all hours post surgery was lower than the lateral group, especially at 6, 12 and 24 hours after the surgery and the difference was statistically significant ( p =0.03, p <0.004, p =0.001). The results of this study show that ultrasound-guided posterior TAP block compared with the lateral TAP block was more effective in pain control after cesarean section.

  11. Anatomy of a Silicon Compiler

    DTIC Science & Technology

    1994-10-04

    Recognition 321 Anton StOWz*e 21.1. ALGORITHM AND ARCHITECTURE ............... 322 21.2. SYSTEM ARCHITECTURE .................... 325 213. CHIP ARCHiTECTURES...age controlled switch. The second is a linear model where each transistor is mod- eled by a voltage controlled switch in series with a resistor, and...the blocks being co- linear . Routing channels separate blocks which are adjacent. Channels are also placed along the top edge of each block in order to

  12. Adaptive control applied to Space Station attitude control system

    NASA Technical Reports Server (NTRS)

    Lam, Quang M.; Chipman, Richard; Hu, Tsay-Hsin G.; Holmes, Eric B.; Sunkel, John

    1992-01-01

    This paper presents an adaptive control approach to enhance the performance of current attitude control system used by the Space Station Freedom. The proposed control law was developed based on the direct adaptive control or model reference adaptive control scheme. Performance comparisons, subject to inertia variation, of the adaptive controller and the fixed-gain linear quadratic regulator currently implemented for the Space Station are conducted. Both the fixed-gain and the adaptive gain controllers are able to maintain the Station stability for inertia variations of up to 35 percent. However, when a 50 percent inertia variation is applied to the Station, only the adaptive controller is able to maintain the Station attitude.

  13. Fatigue limits of monolithic Y-TZP three-unit-fixed dental prostheses: effect of grinding at the gingival zone of the connector

    PubMed Central

    Amaral, Marina; Rocha, Regina FV; Melo, Renata Marques; Pereira, Gabriel KR; Zhang, Yu; Valandro, Luiz Felipe; Bottino, Marco Antonio

    2017-01-01

    Objectives To determine the fatigue limits of three-unit monolithic zirconia FDPs before and after grinding of the gingival areas of connectors with diamond burs. Material and Methods FDPs were milled from pre-sintered blocks of zirconia simulating the absence of the first mandibular molar. Half of the specimens were subjected to grinding, simulating clinical adjustment, and all of them were subjected to glazing procedure. Additional specimens were manufactured for roughness analysis. FDPs were adhesively cemented onto glass-fiber reinforced epoxy resin abutments. Fatigue limits and standard deviations were obtained using a staircase fatigue method (n = 20, 100,000 loading cycles/5 Hz). The initial test load was 70% of the mean load-to-fracture (n = 3) and load increments were 5% of the initial test load for both the control and ground specimens. Data were compared by Student’s T-test (α ≤ 0.05). Results Both the control and ground groups exhibited similar values of load-to-fracture and fatigue limits. Neither the surface treatments nor ageing affected the surface roughness of the specimens. Conclusions The damage induced by grinding with fine-grit diamond bur in the gingival area of the connectors did not decrease the fatigue limit of the three-unit monolithic zirconia FDP. PMID:28494273

  14. Static aeroelastic analysis and tailoring of missile control fins

    NASA Technical Reports Server (NTRS)

    Mcintosh, S. C., Jr.; Dillenius, M. F. E.

    1989-01-01

    A concept for enhancing the design of control fins for supersonic tactical missiles is described. The concept makes use of aeroelastic tailoring to create fin designs (for given planforms) that limit the variations in hinge moments that can occur during maneuvers involving high load factors and high angles of attack. It combines supersonic nonlinear aerodynamic load calculations with finite-element structural modeling, static and dynamic structural analysis, and optimization. The problem definition is illustrated. The fin is at least partly made up of a composite material. The layup is fixed, and the orientations of the material principal axes are allowed to vary; these are the design variables. The objective is the magnitude of the difference between the chordwise location of the center of pressure and its desired location, calculated for a given flight condition. Three types of constraints can be imposed: upper bounds on static displacements for a given set of load conditions, lower bounds on specified natural frequencies, and upper bounds on the critical flutter damping parameter at a given set of flight speeds and altitudes. The idea is to seek designs that reduce variations in hinge moments that would otherwise occur. The block diagram describes the operation of the computer program that accomplishes these tasks. There is an option for a single analysis in addition to the optimization.

  15. Three-dimensional visualization and a deep-learning model reveal complex fungal parasite networks in behaviorally manipulated ants

    PubMed Central

    Fredericksen, Maridel A.; Zhang, Yizhe; Hazen, Missy L.; Loreto, Raquel G.; Mangold, Colleen A.; Chen, Danny Z.; Hughes, David P.

    2017-01-01

    Some microbes possess the ability to adaptively manipulate host behavior. To better understand how such microbial parasites control animal behavior, we examine the cell-level interactions between the species-specific fungal parasite Ophiocordyceps unilateralis sensu lato and its carpenter ant host (Camponotus castaneus) at a crucial moment in the parasite’s lifecycle: when the manipulated host fixes itself permanently to a substrate by its mandibles. The fungus is known to secrete tissue-specific metabolites and cause changes in host gene expression as well as atrophy in the mandible muscles of its ant host, but it is unknown how the fungus coordinates these effects to manipulate its host’s behavior. In this study, we combine techniques in serial block-face scanning-electron microscopy and deep-learning–based image segmentation algorithms to visualize the distribution, abundance, and interactions of this fungus inside the body of its manipulated host. Fungal cells were found throughout the host body but not in the brain, implying that behavioral control of the animal body by this microbe occurs peripherally. Additionally, fungal cells invaded host muscle fibers and joined together to form networks that encircled the muscles. These networks may represent a collective foraging behavior of this parasite, which may in turn facilitate host manipulation. PMID:29114054

  16. Effects of antibacterial primers with quaternary ammonium and nano-silver on S. mutans impregnated in human dentin blocks

    PubMed Central

    Cheng, Lei; Zhang, Ke; Weir, Michael D.; Liu, Huaibing; Zhou, Xuedong; Xu, Hockin H. K.

    2013-01-01

    Objectives Recent studies developed antibacterial bonding agents and composites containing a quaternary ammonium dimethacrylate (QADM) and nanoparticles of silver (NAg). The objectives of this study were to investigate: (1) the effect of antibacterial primers containing QADM and NAg on the inhibition of Streptococcus mutans (S. mutans) impregnated into dentin blocks for the first time, and (2) the effect of QADM or NAg alone or in combination, and the effect of NAg mass fraction, on S. mutans viability in dentin. Methods Scotchbond Multi-Purpose (SBMP) bonding agent was used. QADM and NAg were incorporated into SBMP primer. Six primers were tested: SBMP primer control, control + 10% QADM (mass %), control + 0.05% NAg, control + 10% QADM + 0.05% NAg, control + 0.1% NAg, and control + 10% QADM + 0.1% NAg. S. mutans were impregnated into dentin blocks, then a primer was applied. The viable colony-forming units (CFU) were then measured by harvesting the bacteria in dentin using a sonication method. Results Control + 10% QADM + 0.1% NAg had bacteria inhibition zone 8-fold that of control (p < 0.05). The sonication method successfully harvested bacteria from dentin blocks. Control + 10% QADM + 0.1% NAg inhibited S. mutans in dentin blocks, reducing the viable CFU in dentin by three orders of magnitude, compared to control dentin without primer. Using QADM+NAg was more effective than QADM alone. Higher NAg content increased the potency. Dentin shear bond strength was similar for all groups (p > 0.1). Significance Antibacterial primer with QADM and NAg were shown to inhibit the S. mutans impregnated into dentin blocks for the first time. Bonding agent containing QADM and NAg is promising to eradicate bacteria in tooth cavity and inhibit caries. The QADM and NAg may have applicability to other adhesives, cements, sealants and composites. PMID:23422420

  17. Rupture loop annex ion exchange RLAIX vault deactivation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ham, J.E.; Harris, D.L., Westinghouse Hanford

    This engineering report documents the deactivation, stabilization and final conditions of the Rupture Loop Annex Ion Exchange (RLAIX) Vault located northwest of the 309 Building`s Plutonium Recycle Test Reactor (PRTR). Twelve ion exchange columns, piping debris, and column liquid were removed from the vault, packaged and shipped for disposal. The vault walls and floor were decontaminated, and portions of the vault were painted to fix loose contamination. Process piping and drains were plugged, and the cover blocks and rain cover were installed. Upon closure,the vault was empty, stabilized, isolated.

  18. Bit-wise arithmetic coding for data compression

    NASA Technical Reports Server (NTRS)

    Kiely, A. B.

    1994-01-01

    This article examines the problem of compressing a uniformly quantized independent and identically distributed (IID) source. We present a new compression technique, bit-wise arithmetic coding, that assigns fixed-length codewords to the quantizer output and uses arithmetic coding to compress the codewords, treating the codeword bits as independent. We examine the performance of this method and evaluate the overhead required when used block-adaptively. Simulation results are presented for Gaussian and Laplacian sources. This new technique could be used as the entropy coder in a transform or subband coding system.

  19. Controlling cyanobacterial blooms in hypertrophic Lake Taihu, China: will nitrogen reductions cause replacement of non-N2 fixing by N2 fixing taxa?

    PubMed

    Paerl, Hans W; Xu, Hai; Hall, Nathan S; Zhu, Guangwei; Qin, Boqiang; Wu, Yali; Rossignol, Karen L; Dong, Linghan; McCarthy, Mark J; Joyner, Alan R

    2014-01-01

    Excessive anthropogenic nitrogen (N) and phosphorus (P) inputs have caused an alarming increase in harmful cyanobacterial blooms, threatening sustainability of lakes and reservoirs worldwide. Hypertrophic Lake Taihu, China's third largest freshwater lake, typifies this predicament, with toxic blooms of the non-N2 fixing cyanobacteria Microcystis spp. dominating from spring through fall. Previous studies indicate N and P reductions are needed to reduce bloom magnitude and duration. However, N reductions may encourage replacement of non-N2 fixing with N2 fixing cyanobacteria. This potentially counterproductive scenario was evaluated using replicate, large (1000 L), in-lake mesocosms during summer bloom periods. N+P additions led to maximum phytoplankton production. Phosphorus enrichment, which promoted N limitation, resulted in increases in N2 fixing taxa (Anabaena spp.), but it did not lead to significant replacement of non-N2 fixing with N2 fixing cyanobacteria, and N2 fixation rates remained ecologically insignificant. Furthermore, P enrichment failed to increase phytoplankton production relative to controls, indicating that N was the most limiting nutrient throughout this period. We propose that Microcystis spp. and other non-N2 fixing genera can maintain dominance in this shallow, highly turbid, nutrient-enriched lake by outcompeting N2 fixing taxa for existing sources of N and P stored and cycled in the lake. To bring Taihu and other hypertrophic systems below the bloom threshold, both N and P reductions will be needed until the legacy of high N and P loading and sediment nutrient storage in these systems is depleted. At that point, a more exclusive focus on P reductions may be feasible.

  20. Controlling Cyanobacterial Blooms in Hypertrophic Lake Taihu, China: Will Nitrogen Reductions Cause Replacement of Non-N2 Fixing by N2 Fixing Taxa?

    PubMed Central

    Paerl, Hans W.; Xu, Hai; Hall, Nathan S.; Zhu, Guangwei; Qin, Boqiang; Wu, Yali; Rossignol, Karen L.; Dong, Linghan; McCarthy, Mark J.; Joyner, Alan R.

    2014-01-01

    Excessive anthropogenic nitrogen (N) and phosphorus (P) inputs have caused an alarming increase in harmful cyanobacterial blooms, threatening sustainability of lakes and reservoirs worldwide. Hypertrophic Lake Taihu, China’s third largest freshwater lake, typifies this predicament, with toxic blooms of the non-N2 fixing cyanobacteria Microcystis spp. dominating from spring through fall. Previous studies indicate N and P reductions are needed to reduce bloom magnitude and duration. However, N reductions may encourage replacement of non-N2 fixing with N2 fixing cyanobacteria. This potentially counterproductive scenario was evaluated using replicate, large (1000 L), in-lake mesocosms during summer bloom periods. N+P additions led to maximum phytoplankton production. Phosphorus enrichment, which promoted N limitation, resulted in increases in N2 fixing taxa (Anabaena spp.), but it did not lead to significant replacement of non-N2 fixing with N2 fixing cyanobacteria, and N2 fixation rates remained ecologically insignificant. Furthermore, P enrichment failed to increase phytoplankton production relative to controls, indicating that N was the most limiting nutrient throughout this period. We propose that Microcystis spp. and other non-N2 fixing genera can maintain dominance in this shallow, highly turbid, nutrient-enriched lake by outcompeting N2 fixing taxa for existing sources of N and P stored and cycled in the lake. To bring Taihu and other hypertrophic systems below the bloom threshold, both N and P reductions will be needed until the legacy of high N and P loading and sediment nutrient storage in these systems is depleted. At that point, a more exclusive focus on P reductions may be feasible. PMID:25405474

Top