Sample records for fixed concentration procedure

  1. Optical analysis of a curved-slats fixed-mirror solar concentrator by a forward ray-tracing procedure.

    PubMed

    Pujol Nadal, Ramon; Martínez Moll, Víctor

    2013-10-20

    Fixed-mirror solar concentrators (FMSCs) use a static reflector and a moving receiver. They are easily installable on building roofs. However, for high-concentration factors, several flat mirrors would be needed. If curved mirrors are used instead, high-concentration levels can be achieved, and such a solar concentrator is called a curved-slats fixed-mirror solar concentrator (CSFMSC), on which little information is available. Herein, a methodology is proposed to characterize the CSFMSC using 3D ray-tracing tools. The CSFMSC shows better optical characteristics than the FMSC, as it needs fewer reflector segments for achieving the same concentration and optical efficiency.

  2. Perioperative haemostatic management of haemophilic mice using normal mouse plasma.

    PubMed

    Tatsumi, K; Ohashi, K; Kanegae, K; Shim, I K; Okano, T

    2013-11-01

    Intense haemostatic interventions are required to avoid bleeding complications when surgical procedures are performed on haemophilia patients. The objective of this study was to establish an appropriate protocol for perioperative haemostatic management of haemophilic mice. We assessed the prophylactic haemostatic effects of normal mouse plasma (NMP) on haemophilia B (HB) mice for both a skin flap procedure and a laparotomy. When 500 μL of NMP was administered to the mice, plasma factor IX (FIX:C) levels peaked at 15.1% immediately after intravenous (IV) administration, at 6.1% 2 h after intraperitoneal (IP) administration and at 2.7% 6 h after subcutaneous administration. Administering 500 μL of NMP via IP or IV 30 min in advance enabled the skin flap procedure to be performed safely without any complications. After the laparotomy procedure, several mice in the IP administration group exhibited lethal bleeding, but all mice survived in the IV administration group. Anti-mouse FIX inhibitors did not develop, even after repetitive administrations of NMP. However, human FIX concentrates, especially plasma-derived concentrates, elicited the anti-human FIX inhibitors. The results show that administering 500 μL of NMP via IV or IP 30 min in advance enables surgical procedures to be safely performed on HB mice, and that IV administration is more desirable than IP if the procedure requires opening of the abdominal wall. © 2013 John Wiley & Sons Ltd.

  3. Effect of different surgical procedures on the accuracy of prediction of the plasma concentration of fentanyl: comparison between mastectomy and laparoscopic prostatectomy.

    PubMed

    Fujita, Yoshihito; Yoshizawa, Saya; Hoshika, Maiko; Inoue, Koichi; Matsushita, Shoko; Oka, Hisao; Sobue, Kazuya

    2017-01-01

    The accuracy of simulation-predicted fentanyl concentration in different types of surgical procedure is not fully understood. We wished to estimate the effect of different types of surgical procedure on the accuracy of such simulations. Fifty patients who had undergone elective mastectomy or laparoscopic prostatectomy (American Society of Anesthesiologists physical status = I-II) were enrolled. Anesthesia was maintained throughout surgery with sevoflurane and a bolus infusion of fentanyl. A maintenance infusion was administered with 8 mL/kg/h Ringer's acetate solution from the start of anesthesia to completion of blood sampling. An infusion to compensate for blood loss was administered (one to two volumes of hydroxyethyl starch). A blood sample was drawn every 30 min during anesthesia.We measured the plasma concentration of fentanyl in 358 samples from 50 patients. The plasma concentration of fentanyl was correlated significantly with the simulated predicted fentanyl concentration ( r  = 0.734, P  < 0.01) but 36.0% of all samples had a difference greater than ±0.5 ng/mL. Approximately 0.3 ng/mL of a fixed bias was shown throughout mastectomy. During laparoscopic prostatectomy, the fixed bias gradually became negative from ≈0.3 to -0.3 ng/mL as the sampling stage proceeded. The predicted concentration of fentanyl was significantly correlated with the plasma concentration of fentanyl ( r  = 0.734). However, there were different patterns of a fixed bias between mastectomy and laparoscopic prostatectomy groups. We should pay attention to this tendency among different surgical procedures. UMIN000005110.

  4. 40 CFR 53.23 - Test procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... up and stabilize. Determine measurement noise at each of two fixed concentrations, first using zero.... Note to § 53.23(b)(2): Use of a chart recorder in addition to the DM is optional. (iii) Measure zero... atmosphere concentration of 80 ±5 percent of the URL instead of zero air, and let S at 80 percent of the URL...

  5. 40 CFR 53.23 - Test procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... up and stabilize. Determine measurement noise at each of two fixed concentrations, first using zero.... Note to § 53.23(b)(2): Use of a chart recorder in addition to the DM is optional. (iii) Measure zero... atmosphere concentration of 80 ±5 percent of the URL instead of zero air, and let S at 80 percent of the URL...

  6. 40 CFR 53.23 - Test procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... up and stabilize. Determine measurement noise at each of two fixed concentrations, first using zero.... Note to § 53.23(b)(2): Use of a chart recorder in addition to the DM is optional. (iii) Measure zero... atmosphere concentration of 80 ±5 percent of the URL instead of zero air, and let S at 80 percent of the URL...

  7. Ethanol-reinforced responding by AA and ANA rats following the sucrose-substitution initiation procedure.

    PubMed

    Files, F J; Denning, C E; Hyytia, P; Kiianmaa, K; Samson, H H

    1997-06-01

    Ethanol-reinforced responding was initiated in male AA and ANA rats using the sucrose-substitution procedure. Before the initiation procedure, a homecage, two-bottle preference test was conducted. The rats were then trained to respond on an Fixed-Ratio 1 schedule with sucrose reinforcement. Over sessions, ethanol was added gradually to the sucrose solution as the concentration of sucrose was reduced until 10% ethanol (v/v) alone functioned as the reinforcer for lever pressing. The schedule of reinforcement was then increased to Fixed-Ratio 4. Next, the ethanol concentration presented as the reinforcer was increased over weeks to 15%, 20%, 30%, and then returned to 10%. A second homecage test was then performed. The results showed that the AA and ANA lines differed significantly on preference and intake (g/kg) during the homecage preference tests. There was a significant increase in preference during the second homecage test. During sucrose substitution, initial large differences in responding were observed between the lines. When the ethanol concentration was increased, intake (grams per kilogram) increased for the AA line but not for the ANA line. These effects were a function of no change in responding by the AA rats as concentration was increased and a decrease in responding by the ANA rats at the higher concentrations (20% and 30%). Taken together, data indicate that ethanol can function as a positive reinforcer for the behavior of AA and ANA rats. Even though 10% ethanol functioned as a reinforcer similarly for the two lines, ethanol intake in the AA line was significantly greater at the higher concentrations of ethanol, suggesting that ethanol functioned as a qualitatively different reinforcer for the AA rats, compared with the ANA rats.

  8. 40 CFR 63.1413 - Compliance demonstration procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... measured and used to establish the outlet organic HAP concentration. (iii) For a carbon adsorption system that regenerates the carbon bed directly onsite in the control device, such as a fixed-bed adsorber... time, number and capacity of carbon beds, type and working capacity of activated carbon used for carbon...

  9. 40 CFR 63.1413 - Compliance demonstration procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... measured and used to establish the outlet organic HAP concentration. (iii) For a carbon adsorption system that regenerates the carbon bed directly onsite in the control device, such as a fixed-bed adsorber... time, number and capacity of carbon beds, type and working capacity of activated carbon used for carbon...

  10. Deconstructing the vanilla milkshake: the dominant effect of sucrose on self-administration of nutrient-flavor mixtures.

    PubMed

    Naleid, Amy M; Grimm, Jeffrey W; Kessler, David A; Sipols, Alfred J; Aliakbari, Sepideh; Bennett, Jennifer L; Wells, Jason; Figlewicz, Dianne P

    2008-01-01

    Rats and humans avidly consume flavored foods that contain sucrose and fat, presumably due to their rewarding qualities. In this study, we hypothesized that the complex mixture of corn oil, sucrose, and flavor is more reinforcing than any of these components alone. We observed a concentration-dependent increase in reinforcers of sucrose solutions received (0%, 3%, 6.25%, and 12.5%) in both fixed ratio and progressive ratio procedures, but with equicaloric corn oil solutions (0%, 1.4%, 2.8%, and 5.6%) this finding was replicated only in the fixed ratio procedure. Likewise, addition of 1.4% oil to 3% or 12.5% sucrose increased fixed ratio, but not progressive ratio, reinforcers received relative to those of sucrose alone. Finally, addition of 3% vanilla flavoring did not change self-administration of 3% sucrose or 3% sucrose+1.4% oil solutions. These data suggest that, calorie-for-calorie, sucrose is the dominant reinforcing component of novel foods that contain a mixture of fat, sucrose, and flavor.

  11. DECONSTRUCTING THE VANILLA MILKSHAKE: THE DOMINANT EFFECT OF SUCROSE ON SELF-ADMINISTRATION OF NUTRIENT-FLAVOR MIXTURES

    PubMed Central

    Naleid, Amy M.; Grimm, Jeffrey W.; Kessler, David A.; Sipols, Alfred J.; Aliakbari, Sepideh; Bennett, Jennifer L.; Wells, Jason; Figlewicz, Dianne P.

    2007-01-01

    Rats and humans avidly consume flavored foods that contain sucrose and fat, presumably due to their rewarding qualities. In this study, we hypothesized that the complex mixture of corn oil, sucrose, and flavor is more reinforcing than any of these components alone. We observed a concentration-dependent increase in reinforcers received of sucrose solutions (0, 3, 6.25, and 12.5%) in both fixed ratio and progressive ratio procedures, but with equicaloric corn oil solutions (0, 1.4, 2.8, and 5.6%) this finding was replicated only in the fixed ratio procedure. Likewise, addition of 1.4% oil to 3% or 12.5% sucrose increased fixed ratio, but not progressive ratio, reinforcers received relative to those of sucrose alone. Finally, addition of 3% vanilla flavoring did not change self-administration of 3% sucrose or 3% sucrose + 1.4% oil solutions. These data suggest that, calorie-for-calorie, sucrose is the dominant reinforcing component of novel foods that contain a mixture of fat, sucrose, and flavor. PMID:17707949

  12. A BRST gauge-fixing procedure for Yang Mills theory on sphere

    NASA Astrophysics Data System (ADS)

    Banerjee, Rabin; Deguchi, Shinichi

    2006-01-01

    A gauge-fixing procedure for the Yang-Mills theory on an n-dimensional sphere (or a hypersphere) is discussed in a systematic manner. We claim that Adler's gauge-fixing condition used in massless Euclidean QED on a hypersphere is not conventional because of the presence of an extra free index, and hence is unfavorable for the gauge-fixing procedure based on the BRST invariance principle (or simply BRST gauge-fixing procedure). Choosing a suitable gauge condition, which is proved to be equivalent to a generalization of Adler's condition, we apply the BRST gauge-fixing procedure to the Yang-Mills theory on a hypersphere to obtain consistent results. Field equations for the Yang-Mills field and associated fields are derived in manifestly O (n + 1) covariant or invariant forms. In the large radius limit, these equations reproduce the corresponding field equations defined on the n-dimensional flat space.

  13. Quantification of cell surface receptor expression in live tissue culture media using a dual-tracer stain and rinse approach

    NASA Astrophysics Data System (ADS)

    Xu, Xiaochun; Sinha, Lagnojita; Singh, Aparna; Yang, Cynthia; Xiang, Jialing; Tichauer, Kenneth M.

    2015-03-01

    Immunofluorescence staining is a robust way to visualize the distribution of targeted biomolecules invasively in in fixed tissues and tissue culture. Despite the fact that these methods has been a well-established method in fixed tissue imaging for over 70 years, quantification of receptor concentration still simply assumes that the signal from the targeted fluorescent marker after incubation and sufficient rinsing is directly proportional to the concentration of targeted biomolecules, thus neglecting the experimental inconsistencies in incubation and rinsing procedures and assuming no, nonspecific binding of the fluorescent markers. This work presents the first imaging approach capable of quantifying the concentration of cell surface receptor on cancer cells grown in vitro based on compartment modeling in a nondestructive way. The approach utilizes a dual-tracer protocol where any non-specific retention or variability in incubation and rinsing of a receptor-targeted imaging agent is corrected by simultaneously imaging the retention of a chemically similar, "untargeted" imaging agent. Various different compartment models were used to analyze the data in order to find the optimal procedure for extracting estimates of epidermal growth factor receptor (EGFR) concentration (a receptor overexpressed in many cancers and a key target for emerging molecular therapies) in tissue cultures with varying concentrations of human glioma cells (U251). Preliminary results demonstrated a need to model nonspecific binding of both the targeted and untargeted imaging agents used. The approach could be used to carry out the first repeated measures of cell surface receptor dynamics during 3D tumor mass development, in addition to the receptor response to therapies.

  14. Diffusion of a Concentrated Lattice Gas in a Regular Comb Structure

    NASA Astrophysics Data System (ADS)

    Garcia, Paul; Wentworth, Christopher

    2008-10-01

    Understanding diffusion in constrained geometries is of interest in a variety of contexts as varied as mass transport in disordered solids, such as a percolation cluster, or intercellular transport of water molecules in biological tissue. In this investigation we explore diffusion in a very simple constrained geometry: a comb-like structure involving a one-dimensional backbone of lattice sites with regularly spaced teeth of fixed length. The model considered assumes a fixed concentration of diffusing particles can hop to nearest-neighbor sites only, and they do not interact with each other except that double occupancy is not allowed. The system is simulated using a Monte Carlo simulation procedure. The mean-square displacement of a tagged particle is calculated from the simulation as a function of time. The simulation shows normal diffusive behavior after a period of anomalous diffusion that increases as the tooth size increases.

  15. [Successful management of neurosurgical procedures with continuous infusion of recombinant factor IX in a child with hemophilia B].

    PubMed

    Yamamoto, Mariko; Nakadate, Hisaya; Iguchi, Umefumi; Masuda, Hiroshi; Sakai, Hirokazu; Ishiguro, Akira

    2013-03-01

    This report describes the successful management of neurosurgical procedures with continuous infusion of recombinant factor IX (rFIX). A 1-year-old boy with severe hemophilia B was administered prophylactic therapy with rFIX after intracranial bleeding. We found the enlargement of an arachnoid cyst in a follow-up CT scan. He underwent marsupialization of the cyst under the continuous infusion of rFIX. FIX levels were examined in our hospital and the rFIX infusion rate was adjusted in an attempt to keep FIX levels above 90% intraoperatively, and 70% until his 7th post-operative day. We studied the pharmacokinetic profile of rFIX and found a half-time of 25 hours and mean in vivo recovery of 0.69 IU/dl/IU/kg. Reconstituted rFIX also retained at least 95% activity after 72 hours at room temperature. This is the first report of the perioperative management of a child undergoing a neurosurgical procedure under the continuous infusion of rFIX in Japan. Further studies are required before the routine use of this product for continuous infusion.

  16. Fixation and chemical analysis of single fog and rain droplets

    NASA Astrophysics Data System (ADS)

    Kasahara, M.; Akashi, S.; Ma, C.-J.; Tohno, S.

    Last decade, the importance of global environmental problems has been recognized worldwide. Acid rain is one of the most important global environmental problems as well as the global warming. The grasp of physical and chemical properties of fog and rain droplets is essential to make clear the physical and chemical processes of acid rain and also their effects on forests, materials and ecosystems. We examined the physical and chemical properties of single fog and raindrops by applying fixation technique. The sampling method and treatment procedure to fix the liquid droplets as a solid particle were investigated. Small liquid particles like fog droplet could be easily fixed within few minutes by exposure to cyanoacrylate vapor. The large liquid particles like raindrops were also fixed successively, but some of them were not perfect. Freezing method was applied to fix the large raindrops. Frozen liquid particles existed stably by exposure to cyanoacrylate vapor after freezing. The particle size measurement and the elemental analysis of the fixed particle were performed in individual base using microscope, and SEX-EDX, particle-induced X-ray emission (PIXE) and micro-PIXE analyses, respectively. The concentration in raindrops was dependent upon the droplet size and the elapsed time from the beginning of rainfall.

  17. Hypothesis testing for the validation of the kinetic spectrophotometric methods for the determination of lansoprazole in bulk and drug formulations via Fe(III) and Zn(II) chelates.

    PubMed

    Rahman, Nafisur; Kashif, Mohammad

    2010-03-01

    Point and interval hypothesis tests performed to validate two simple and economical, kinetic spectrophotometric methods for the assay of lansoprazole are described. The methods are based on the formation of chelate complex of the drug with Fe(III) and Zn(II). The reaction is followed spectrophotometrically by measuring the rate of change of absorbance of coloured chelates of the drug with Fe(III) and Zn(II) at 445 and 510 nm, respectively. The stoichiometric ratio of lansoprazole to Fe(III) and Zn(II) complexes were found to be 1:1 and 2:1, respectively. The initial-rate and fixed-time methods are adopted for determination of drug concentrations. The calibration graphs are linear in the range 50-200 µg ml⁻¹ (initial-rate method), 20-180 µg ml⁻¹ (fixed-time method) for lansoprazole-Fe(III) complex and 120-300 (initial-rate method), and 90-210 µg ml⁻¹ (fixed-time method) for lansoprazole-Zn(II) complex. The inter-day and intra-day precision data showed good accuracy and precision of the proposed procedure for analysis of lansoprazole. The point and interval hypothesis tests indicate that the proposed procedures are not biased. Copyright © 2010 John Wiley & Sons, Ltd.

  18. Personal carbon monoxide exposures of preschool children in Helsinki, Finland—comparison to ambient air concentrations

    NASA Astrophysics Data System (ADS)

    Alm, S.; Mukala, K.; Tiittanen, P.; Jantunen, M. J.

    The associations of personal carbon monoxide (CO) exposures with ambient air CO concentrations measured at fixed monitoring sites, were studied among 194 children aged 3-6 yr in four downtown and four suburban day-care centers in Helsinki, Finland. Each child carried a personal CO exposure monitor between 1 and 4 times for a time period of between 20 and 24 h. CO concentrations at two fixed monitoring sites were measured simultaneously. The CO concentrations measured at the fixed monitoring sites were usually lower (mean maximum 8-h concentration: 0.9 and 2.6 mg m -3) than the personal CO exposure concentrations (mean maximum 8-h concentration: 3.3 mg m -3). The fixed site CO concentrations were poor predictors of the personal CO exposure concentrations. However, the correlations between the personal CO exposure and the fixed monitoring site CO concentrations increased (-0.03--0.12 to 0.13-0.16) with increasing averaging times from 1 to 8 h. Also, the fixed monitoring site CO concentrations explained the mean daily or weekly personal CO exposures of a group of simultaneously measured children better than individual exposure CO concentrations. This study suggests that the short-term CO personal exposure of children cannot be meaningfully assessed using fixed monitoring sites.

  19. Predicting the Best Fit: A Comparison of Response Surface Models for Midazolam and Alfentanil Sedation in Procedures With Varying Stimulation.

    PubMed

    Liou, Jing-Yang; Ting, Chien-Kun; Mandell, M Susan; Chang, Kuang-Yi; Teng, Wei-Nung; Huang, Yu-Yin; Tsou, Mei-Yung

    2016-08-01

    Selecting an effective dose of sedative drugs in combined upper and lower gastrointestinal endoscopy is complicated by varying degrees of pain stimulation. We tested the ability of 5 response surface models to predict depth of sedation after administration of midazolam and alfentanil in this complex model. The procedure was divided into 3 phases: esophagogastroduodenoscopy (EGD), colonoscopy, and the time interval between the 2 (intersession). The depth of sedation in 33 adult patients was monitored by Observer Assessment of Alertness/Scores. A total of 218 combinations of midazolam and alfentanil effect-site concentrations derived from pharmacokinetic models were used to test 5 response surface models in each of the 3 phases of endoscopy. Model fit was evaluated with objective function value, corrected Akaike Information Criterion (AICc), and Spearman ranked correlation. A model was arbitrarily defined as accurate if the predicted probability is <0.5 from the observed response. The effect-site concentrations tested ranged from 1 to 76 ng/mL and from 5 to 80 ng/mL for midazolam and alfentanil, respectively. Midazolam and alfentanil had synergistic effects in colonoscopy and EGD, but additivity was observed in the intersession group. Adequate prediction rates were 84% to 85% in the intersession group, 84% to 88% during colonoscopy, and 82% to 87% during EGD. The reduced Greco and Fixed alfentanil concentration required for 50% of the patients to achieve targeted response Hierarchy models performed better with comparable predictive strength. The reduced Greco model had the lowest AICc with strong correlation in all 3 phases of endoscopy. Dynamic, rather than fixed, γ and γalf in the Hierarchy model improved model fit. The reduced Greco model had the lowest objective function value and AICc and thus the best fit. This model was reliable with acceptable predictive ability based on adequate clinical correlation. We suggest that this model has practical clinical value for patients undergoing procedures with varying degrees of stimulation.

  20. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR OPERATION, CALIBRATION AND MAINTENANCE OF FIXED AND ADJUSTABLE VOLUME PIPETTE GUNS (BCO-L-9.0)

    EPA Science Inventory

    The purpose of this SOP is to describe the general procedures for the operation, calibration, and maintenance of fixed- and adjustable-volume pipette guns. This procedure was followed to ensure consistent data retrieval during the Arizona NHEXAS project and the "Border" study. Ke...

  1. The behavioral economics of drug self-administration: A review and new analytical approach for within-session procedures

    PubMed Central

    Bentzley, Brandon S.; Fender, Kimberly M.; Aston-Jones, Gary

    2012-01-01

    Rationale Behavioral-economic demand curve analysis offers several useful measures of drug self-administration. Although generation of demand curves previously required multiple days, recent within-session procedures allow curve construction from a single 110-min cocaine self-administration session, making behavioral-economic analyses available to a broad range of self-administration experiments. However, a mathematical approach of curve fitting has not been reported for the within-session threshold procedure. Objectives We review demand curve analysis in drug self-administration experiments and provide a quantitative method for fitting curves to single-session data that incorporates relative stability of brain drug concentration. Methods Sprague-Dawley rats were trained to self-administer cocaine, and then tested with the threshold procedure in which the cocaine dose was sequentially decreased on a fixed ratio-1 schedule. Price points (responses/mg cocaine) outside of relatively stable brain cocaine concentrations were removed before curves were fit. Curve-fit accuracy was determined by the degree of correlation between graphical and calculated parameters for cocaine consumption at low price (Q0) and the price at which maximal responding occurred (Pmax). Results Removing price points that occurred at relatively unstable brain cocaine concentrations generated precise estimates of Q0 and resulted in Pmax values with significantly closer agreement with graphical Pmax than conventional methods. Conclusion The exponential demand equation can be fit to single-session data using the threshold procedure for cocaine self-administration. Removing data points that occur during relatively unstable brain cocaine concentrations resulted in more accurate estimates of demand curve slope than graphical methods, permitting a more comprehensive analysis of drug self-administration via a behavioral-economic framework. PMID:23086021

  2. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR OPERATION, CALIBRATION AND MAINTENANCE OF FIXED AND ADJUSTABLE VOLUME PIPETTE GUNS (BCO-L-9.0)

    EPA Science Inventory

    The purpose of this SOP is to describe the general procedures for the operation, calibration, and maintenance of fixed- and adjustable-volume pipette guns. This procedure was followed to ensure consistent data retrieval during the Arizona NHEXAS project and the Border study. Keyw...

  3. Electrophoretic purification of cells in space - Evaluation of results from STS-3

    NASA Technical Reports Server (NTRS)

    Sarnoff, B. E.; Kunze, M. E.; Todd, P.

    1983-01-01

    The procedure and results of Electrophoresis Equipment Verification Test, designed to examine electrophoretic behavior of animal cells is suspension more concentrated than possible on earth and flown on the Shuttle flight STS-3, were discussed. Ground-based laboratory values of electrophoretic mobilities of a mixture of human and rabbit aldehyde-fixed red blood cells (RBC) were compared with those recorded at 11 minute intervals on the Shuttle STS-3. RBC migration and separation observed through photographic records were not as expected. However, cell mobilities and migrating band profiles were consistent with the results of laboratory simulation experiments. It was concluded that zero G electrophoresis of very high concentrations (1 x 10 to the 9th) is possible and similar to electrophoresis of normal cell concentrations on earth.

  4. Changes in oral ethanol self-administration patterns resulting from ethanol concentration manipulations.

    PubMed

    Slawecki, C J; Samson, H H

    1997-09-01

    A variety of initiation procedures have been used to develop oral ethanol consumption. Using the sucrose-substitution procedure, oral self-administration of ethanol-water solutions with ethanol concentrations as high as 40% can be initiated in food- and fluid-sated rats. An important question for these models is the relationship between ethanol concentration and self-administration patterns after initiation. This study examined the differential patterns of ethanol self-administration maintained by a range of ethanol solutions (10 to 30%) over a 5-week period, compared with rats maintained on 10% ethanol for 5 weeks. In 43 male Long Evans rats, the sucrose-substitution procedure was used to initiate responding maintained by 10% ethanol on a Fixed Ratio 4 schedule of reinforcement. The ethanol concentration presented was then increased to 30% in stepwise fashion and then returned to 10% [Ethanol Concentration Manipulation (ECM) group, n = 32], or 10% ethanol was maintained as the reinforcer for 5 weeks [Control (Con) group, n = 11]. Significant increases in ethanol intake and decreases in responding were associated with increased ethanol concentration. Although no overall differences in total session responding were observed in either group between week 1 and week 5 (10E vs. 10E), examination of changes in initial low responders of the ECM group revealed significant increases in responding that were not observed in the initial low responders of the Con group. Significant increases in momentary response rates were observed on both the ECM and Con groups, independent of the ethanol concentration presented. Increases in response rate in the ECM group were the result of increases in initial low rate and high rate responders; however, the increased response rates in the Con group were the result of increases only in the initial low rate responders. These data suggest that the ECM procedure can aid in the initiation of ethanol self-administration and may be particularly useful in rats of heterogeneous stock.

  5. Fixed-interval performance and self-control in children.

    PubMed Central

    Darcheville, J C; Rivière, V; Wearden, J H

    1992-01-01

    Operant responses of 16 children (mean age 6 years and 1 month) were reinforced according to different fixed-interval schedules (with interreinforcer intervals of 20, 30, or 40 s) in which the reinforcers were either 20-s or 40-s presentations of a cartoon. In another procedure, they received training on a self-control paradigm in which both reinforcer delay (0.5 s or 40 s) and reinforcer duration (20 s or 40 s of cartoons) varied, and subjects were offered a choice between various combinations of delay and duration. Individual differences in behavior under the self-control procedure were precisely mirrored by individual differences under the fixed-interval schedule. Children who chose the smaller immediate reinforcer on the self-control procedure (impulsive) produced short postreinforcement pauses and high response rates in the fixed-interval conditions, and both measures changed little with changes in fixed-interval value. Conversely, children who chose the larger delayed reinforcer in the self-control condition (the self-controlled subjects) exhibited lower response rates and long postreinforcement pauses, which changed systematically with changes in the interval, in their fixed-interval performances. PMID:1573372

  6. Chromatid Paints: A New Method for Detecting Tumor-Specific Chromosomal Inversions

    DTIC Science & Technology

    1999-10-01

    chromosomal DNA as a template for DNA polymerization. The cloning procedure requires copying DNA from fixed cells attached to a glass substrate. Any...achieved by initially fixing cells in methanol and adding acetic acid just before dropping cells onto coverslips. The procedure itself is a novel and...human hybrid cells containing one human #11 chromosome were fixed and dropped onto microscope coverslips. These cells had been synchronized by mitotic

  7. Stability of iterative procedures with errors for approximating common fixed points of a couple of q-contractive-like mappings in Banach spaces

    NASA Astrophysics Data System (ADS)

    Zeng, Lu-Chuan; Yao, Jen-Chih

    2006-09-01

    Recently, Agarwal, Cho, Li and Huang [R.P. Agarwal, Y.J. Cho, J. Li, N.J. Huang, Stability of iterative procedures with errors approximating common fixed points for a couple of quasi-contractive mappings in q-uniformly smooth Banach spaces, J. Math. Anal. Appl. 272 (2002) 435-447] introduced the new iterative procedures with errors for approximating the common fixed point of a couple of quasi-contractive mappings and showed the stability of these iterative procedures with errors in Banach spaces. In this paper, we introduce a new concept of a couple of q-contractive-like mappings (q>1) in a Banach space and apply these iterative procedures with errors for approximating the common fixed point of the couple of q-contractive-like mappings. The results established in this paper improve, extend and unify the corresponding ones of Agarwal, Cho, Li and Huang [R.P. Agarwal, Y.J. Cho, J. Li, N.J. Huang, Stability of iterative procedures with errors approximating common fixed points for a couple of quasi-contractive mappings in q-uniformly smooth Banach spaces, J. Math. Anal. Appl. 272 (2002) 435-447], Chidume [C.E. Chidume, Approximation of fixed points of quasi-contractive mappings in Lp spaces, Indian J. Pure Appl. Math. 22 (1991) 273-386], Chidume and Osilike [C.E. Chidume, M.O. Osilike, Fixed points iterations for quasi-contractive maps in uniformly smooth Banach spaces, Bull. Korean Math. Soc. 30 (1993) 201-212], Liu [Q.H. Liu, On Naimpally and Singh's open questions, J. Math. Anal. Appl. 124 (1987) 157-164; Q.H. Liu, A convergence theorem of the sequence of Ishikawa iterates for quasi-contractive mappings, J. Math. Anal. Appl. 146 (1990) 301-305], Osilike [M.O. Osilike, A stable iteration procedure for quasi-contractive maps, Indian J. Pure Appl. Math. 27 (1996) 25-34; M.O. Osilike, Stability of the Ishikawa iteration method for quasi-contractive maps, Indian J. Pure Appl. Math. 28 (1997) 1251-1265] and many others in the literature.

  8. 47 CFR 101.91 - Involuntary relocation procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses Policies Governing Fixed Service Relocation from the 18.58-19.30 Ghz Band § 101.91 Involuntary relocation procedures. (a) If no agreement is... Commission's rules. FSS licensees are obligated to pay to relocate only the specific microwave links from...

  9. 47 CFR 101.91 - Involuntary relocation procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses Policies Governing Fixed Service Relocation from the 18.58-19.30 Ghz Band § 101.91 Involuntary relocation procedures. (a) If no agreement is... Commission's rules. FSS licensees are obligated to pay to relocate only the specific microwave links from...

  10. 47 CFR 101.91 - Involuntary relocation procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses Policies Governing Fixed Service Relocation from the 18.58-19.30 Ghz Band § 101.91 Involuntary relocation procedures. (a) If no agreement is... Commission's rules. FSS licensees are obligated to pay to relocate only the specific microwave links from...

  11. 47 CFR 101.91 - Involuntary relocation procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses Policies Governing Fixed Service Relocation from the 18.58-19.30 Ghz Band § 101.91 Involuntary relocation procedures. (a) If no agreement is... Commission's rules. FSS licensees are obligated to pay to relocate only the specific microwave links from...

  12. 48 CFR 931.102 - Fixed-price contracts.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Fixed-price contracts. 931... REQUIREMENTS CONTRACT COST PRINCIPLES AND PROCEDURES Applicability 931.102 Fixed-price contracts. The intent of... Government in— (a) Pricing fixed-price prime contracts and modifications, (b) Evaluating the reasonableness...

  13. Legume Shrubs Are More Nitrogen-Homeostatic than Non-legume Shrubs

    PubMed Central

    Guo, Yanpei; Yang, Xian; Schöb, Christian; Jiang, Youxu; Tang, Zhiyao

    2017-01-01

    Legumes are characterized as keeping stable nutrient supply under nutrient-limited conditions. However, few studies examined the legumes' stoichiometric advantages over other plants across various taxa in natural ecosystems. We explored differences in nitrogen (N) and phosphorus (P) stoichiometry of different tissue types (leaf, stem, and root) between N2-fixing legume shrubs and non-N2-fixing shrubs from 299 broadleaved deciduous shrubland sites in northern China. After excluding effects of taxonomy and environmental variables, these two functional groups differed considerably in nutrient regulation. N concentrations and N:P ratios were higher in legume shrubs than in non-N2-fixing shrubs. N concentrations were positively correlated between the plants and soil for non-N2-fixing shrubs, but not for legume shrubs, indicating a stronger stoichiometric homeostasis in legume shrubs than in non-N2-fixing shrubs. N concentrations were positively correlated among three tissue types for non-N2-fixing shrubs, but not between leaves and non-leaf tissues for legume shrubs, demonstrating that N concentrations were more dependent among tissues for non-N2-fixing shrubs than for legume shrubs. N and P concentrations were correlated within all tissues for both functional groups, but the regression slopes were flatter for legume shrubs than non-N2-fixing shrubs, implying that legume shrubs were more P limited than non-N2-fixing shrubs. These results address significant differences in stoichiometry between legume shrubs and non-N2-fixing shrubs, and indicate the influence of symbiotic nitrogen fixation (SNF) on plant stoichiometry. Overall, N2-fixing legume shrubs are higher and more stoichiometrically homeostatic in N concentrations. However, due to excess uptake of N, legumes may suffer from potential P limitation. With their N advantage, legume shrubs could be good nurse plants in restoration sites with degraded soil, but their P supply should be taken care of during management according to our results. PMID:29018468

  14. Legume Shrubs Are More Nitrogen-Homeostatic than Non-legume Shrubs.

    PubMed

    Guo, Yanpei; Yang, Xian; Schöb, Christian; Jiang, Youxu; Tang, Zhiyao

    2017-01-01

    Legumes are characterized as keeping stable nutrient supply under nutrient-limited conditions. However, few studies examined the legumes' stoichiometric advantages over other plants across various taxa in natural ecosystems. We explored differences in nitrogen (N) and phosphorus (P) stoichiometry of different tissue types (leaf, stem, and root) between N 2 -fixing legume shrubs and non-N 2 -fixing shrubs from 299 broadleaved deciduous shrubland sites in northern China. After excluding effects of taxonomy and environmental variables, these two functional groups differed considerably in nutrient regulation. N concentrations and N:P ratios were higher in legume shrubs than in non-N 2 -fixing shrubs. N concentrations were positively correlated between the plants and soil for non-N 2 -fixing shrubs, but not for legume shrubs, indicating a stronger stoichiometric homeostasis in legume shrubs than in non-N 2 -fixing shrubs. N concentrations were positively correlated among three tissue types for non-N 2 -fixing shrubs, but not between leaves and non-leaf tissues for legume shrubs, demonstrating that N concentrations were more dependent among tissues for non-N 2 -fixing shrubs than for legume shrubs. N and P concentrations were correlated within all tissues for both functional groups, but the regression slopes were flatter for legume shrubs than non-N 2 -fixing shrubs, implying that legume shrubs were more P limited than non-N 2 -fixing shrubs. These results address significant differences in stoichiometry between legume shrubs and non-N 2 -fixing shrubs, and indicate the influence of symbiotic nitrogen fixation (SNF) on plant stoichiometry. Overall, N 2 -fixing legume shrubs are higher and more stoichiometrically homeostatic in N concentrations. However, due to excess uptake of N, legumes may suffer from potential P limitation. With their N advantage, legume shrubs could be good nurse plants in restoration sites with degraded soil, but their P supply should be taken care of during management according to our results.

  15. Constraining response output on conjunctive fixed-ratio 1 fixed-time reinforcement schedules: Effects on the postreinforcement pause.

    PubMed

    Lopez, F; Pereira, C

    1985-03-01

    Two experiments used response-restriction procedures in order to test the independence of the factors determining response rate and the factors determining the size of the postreinforcement pause on interval schedules. Responding was restricted by response-produced blackout or by retracting the lever. In Experiment 1 with a Conjunctive FR 1 FT schedule, the blackout procedure reduced the postreinforcement pause more than the lever-retraction procedure did, and both procedures produced shorter pauses than did the schedule without response restriction. In Experiment 2 the interreinforcement interval was also manipulated, and the size of the pause was an increasing function of the interreinforcement interval, but the rate of increase was lower than that produced by fixed interval schedules of comparable interval durations. The assumption of functional independence of the postreinforcement pause and terminal rate in fixed interval schedules is questioned since data suggest that pause reductions resulted from constraining variation in response number compared to equivalent periodic schedules in which response number was allowed to vary. Copyright © 1985. Published by Elsevier B.V.

  16. Side Effects in Time Discounting Procedures: Fixed Alternatives Become the Reference Point

    PubMed Central

    2016-01-01

    Typical research on intertemporal choice utilizes a two-alternative forced choice (2AFC) paradigm requiring participants to choose between a smaller sooner and larger later payoff. In the adjusting-amount procedure (AAP) one of the alternatives is fixed and the other is adjusted according to particular choices made by the participant. Such a method makes the alternatives unequal in status and is speculated to make the fixed alternative a reference point for choices, thereby affecting the decision made. The current study shows that fixing different alternatives in the AAP influences discount rates in intertemporal choices. Specifically, individuals’ (N = 283) choices were affected to just the same extent by merely fixing an alternative as when choices were preceded by scenarios explicitly imposing reference points. PMID:27768759

  17. Choice with a fixed requirement for food, and the generality of the matching relation

    PubMed Central

    Stubbs, D. Alan; Dreyfus, Leon R.; Fetterman, J. Gregor; Dorman, Lana G.

    1986-01-01

    Pigeons were trained on choice procedures in which responses on each of two keys were reinforced probabilistically, but only after a schedule requirement had been met. Under one arrangement, a fixed-interval choice procedure was used in which responses were not reinforced until the interval was over; then a response on one key would be reinforced, with the effective key changing irregularly from interval to interval. Under a second, fixed-ratio choice procedure, responses on either key counted towards completion of the ratio and then, once the ratio had been completed, a response on the probabilistically selected key would produce food. In one experiment, the schedule requirements were varied for both fixed-interval and fixed-ratio schedules. In the second experiment, relative reinforcement rate was varied. And in a third experiment, the duration of an intertrial interval separating choices was varied. The results for 11 pigeons across all three experiments indicate that there were often large deviations between relative response rates and relative reinforcement rates. Overall performance measures were characterized by a great deal of variability across conditions. More detailed measures of choice across the schedule requirement were also quite variable across conditions. In spite of this variability, performance was consistent across conditions in its efficiency of producing food. The absence of matching of behavior allocation to reinforcement rate indicates an important difference between the present procedures and other choice procedures; that difference raises questions about the specific conditions that lead to matching as an outcome. PMID:16812452

  18. Endonasal Skull Base Tumor Removal Using Concentric Tube Continuum Robots: A Phantom Study.

    PubMed

    Swaney, Philip J; Gilbert, Hunter B; Webster, Robert J; Russell, Paul T; Weaver, Kyle D

    2015-03-01

    Objectives The purpose of this study is to experimentally evaluate the use of concentric tube continuum robots in endonasal skull base tumor removal. This new type of surgical robot offers many advantages over existing straight and rigid surgical tools including added dexterity, the ability to scale movements, and the ability to rotate the end effector while leaving the robot fixed in space. In this study, a concentric tube continuum robot was used to remove simulated pituitary tumors from a skull phantom. Design The robot was teleoperated by experienced skull base surgeons to remove a phantom pituitary tumor within a skull. Percentage resection was measured by weight. Resection duration was timed. Setting Academic research laboratory. Main Outcome Measures Percentage removal of tumor material and procedure duration. Results Average removal percentage of 79.8 ± 5.9% and average time to complete procedure of 12.5 ± 4.1 minutes (n = 20). Conclusions The robotic system presented here for use in endonasal skull base surgery shows promise in improving the dexterity, tool motion, and end effector capabilities currently available with straight and rigid tools while remaining an effective tool for resecting the tumor.

  19. Choice in situations of time-based diminishing returns: immediate versus delayed consequences of action.

    PubMed Central

    Hackenberg, T D; Hineline, P N

    1992-01-01

    Pigeons chose between two schedules of food presentation, a fixed-interval schedule and a progressive-interval schedule that began at 0 s and increased by 20 s with each food delivery provided by that schedule. Choosing one schedule disabled the alternate schedule and stimuli until the requirements of the chosen schedule were satisfied, at which point both schedules were again made available. Fixed-interval duration remained constant within individual sessions but varied across conditions. Under reset conditions, completing the fixed-interval schedule not only produced food but also reset the progressive interval to its minimum. Blocks of sessions under the reset procedure were interspersed with sessions under a no-reset procedure, in which the progressive schedule value increased independent of fixed-interval choices. Median points of switching from the progressive to the fixed schedule varied systematically with fixed-interval value, and were consistently lower during reset than during no-reset conditions. Under the latter, each subject's choices of the progressive-interval schedule persisted beyond the point at which its requirements equaled those of the fixed-interval schedule at all but the highest fixed-interval value. Under the reset procedure, switching occurred at or prior to that equality point. These results qualitatively confirm molar analyses of schedule preference and some versions of optimality theory, but they are more adequately characterized by a model of schedule preference based on the cumulated values of multiple reinforcers, weighted in inverse proportion to the delay between the choice and each successive reinforcer. PMID:1548449

  20. Working with a fixed operating room team on consecutive similar cases and the effect on case duration and turnover time.

    PubMed

    Stepaniak, Pieter S; Vrijland, Wietske W; de Quelerij, Marcel; de Vries, Guus; Heij, Christiaan

    2010-12-01

    If variation in procedure times could be controlled or better predicted, the cost of surgeries could be reduced through improved scheduling of surgical resources. This study on the impact of similar consecutive cases on the turnover, surgical, and procedure times tests the perception that repeating the same manual tasks reduces the duration of these tasks. We hypothesize that when a fixed team works on similar consecutive cases the result will be shorter turnover and procedure duration as well as less variation as compared with the situation without a fixed team. Case-control study. St Franciscus Hospital, a large general teaching hospital in Rotterdam, the Netherlands. Two procedures, inguinal hernia repair and laparoscopic cholecystectomy, were selected and divided across a control group and a study group. Patients were randomly assigned to the study or control group. Preparation time, surgical time, procedure time, and turnover time. For inguinal hernia repair, we found a significantly lower preparation time and 10 minutes less procedure time in the study group, as compared with the control group. Variation in the study group was lower, as compared with the control group. For laparoscopic cholecystectomy, preparation time was significantly lower in the study group, as compared with the control group. For both procedures, there was a significant decrease in turnover time. Scheduling similar consecutive cases and performing with a fixed team results in lower turnover times and preparation times. The procedure time of the inguinal hernia repair decreased significantly and has practical scheduling implications. For more complex surgery, like laparoscopic cholecystectomy, there is no effect on procedure time.

  1. Performance of Prototype High-Flow Inhalable Dust Sampler in a Livestock Production Facility

    PubMed Central

    Anthony, T. Renée; Cai, Changjie; Mehaffy, John; Sleeth, Darrah; Volckens, John

    2017-01-01

    A high-flow inhalable sampler, designed for operational flow rates up to 10 L/min using computer simulations and examined in wind tunnel experiments, was evaluated in the field. This prototype sampler was deployed in collocation with an IOM (the benchmark standard sampler) in a swine farrowing building to examine the sampling performance for assessing concentrations of inhalable particulate mass and endotoxin. Paired samplers were deployed for 24-hours on 19 days over a three-month period. On each sampling day, the paired samplers were deployed at three fixed locations and data were analyzed to identify agreement and to examine systematic biases between concentrations measured by these samplers. Thirty-six paired gravimetric samples were analyzed; insignificant, unsubstantial differences between concentrations were identified between the two samplers (p=0.16; mean difference 0.03 mg/m3). Forty-four paired samples were available for endotoxin analysis, and a significant (p=0.001) difference in endotoxin concentration was identified: the prototype sampler, on average, had 120 EU/m3 more endotoxin than did the IOM samples. Since the same gravimetric samples were analyzed for endotoxin content, the endotoxin difference is likely attributable to differences in endotoxin extraction. The prototype’s disposable thin-film polycarbonate capsule was included with the filter in the 1-hour extraction procedure while the internal plastic cassette of the IOM required a rinse procedure that is susceptible to dust losses. Endotoxin concentrations measured with standard plastic IOM inserts that follow this rinsing procedure may underestimate the true endotoxin exposure concentrations. The maximum concentrations in the study (1.55 mg/m3 gravimetric, 2328 EU/m3 endotoxin) were lower than other agricultural or industrial environments. Future work should explore the performance of the prototype sampler in dustier environments, where concentrations approach particulates not otherwise specified (PNOS) limits of 10 mg/m3, including using the prototype as a personal sampler. PMID:27792469

  2. Performance of prototype high-flow inhalable dust sampler in a livestock production facility.

    PubMed

    Anthony, T Renée; Cai, Changjie; Mehaffy, John; Sleeth, Darrah; Volckens, John

    2017-05-01

    A high-flow inhalable sampler, designed for operational flow rates up to 10 L/min using computer simulations and examined in wind tunnel experiments, was evaluated in the field. This prototype sampler was deployed in collocation with an IOM (the benchmark standard sampler) in a swine farrowing building to examine the sampling performance for assessing concentrations of inhalable particulate mass and endotoxin. Paired samplers were deployed for 24 hr on 19 days over a 3-month period. On each sampling day, the paired samplers were deployed at three fixed locations and data were analyzed to identify agreement and to examine systematic biases between concentrations measured by these samplers. Thirty-six paired gravimetric samples were analyzed; insignificant, unsubstantial differences between concentrations were identified between the two samplers (p = 0.16; mean difference 0.03 mg/m 3 ). Forty-four paired samples were available for endotoxin analysis, and a significant (p = 0.001) difference in endotoxin concentration was identified: the prototype sampler, on average, had 120 EU/m 3 more endotoxin than did the IOM samples. Since the same gravimetric samples were analyzed for endotoxin content, the endotoxin difference is likely attributable to differences in endotoxin extraction. The prototype's disposable thin-film polycarbonate capsule was included with the filter in the 1-hr extraction procedure while the internal plastic cassette of the IOM required a rinse procedure that is susceptible to dust losses. Endotoxin concentrations measured with standard plastic IOM inserts that follow this rinsing procedure may underestimate the true endotoxin exposure concentrations. The maximum concentrations in the study (1.55 mg/m 3 gravimetric, 2328 EU/m 3 endotoxin) were lower than other agricultural or industrial environments. Future work should explore the performance of the prototype sampler in dustier environments, where concentrations approach particulates not otherwise specified (PNOS) limits of 10 mg/m 3 , including using the prototype as a personal sampler.

  3. Seasonal cycle of indoor-VOCs: comparison of apartments and cities

    NASA Astrophysics Data System (ADS)

    Schlink, U.; Rehwagen, M.; Damm, M.; Richter, M.; Borte, M.; Herbarth, O.

    On the basis of 2103 measurements of volatile organic compounds (VOCs) in indoor air we study the intensity of a seasonal pattern. The data are representative for the German population and were gathered in different cities (Leipzig, München, Köln), in rooms of different type (children's, living, sleeping rooms, and other rooms), and in households of smokers and non-smokers. In addition to the randomly selected different apartments that were sampled each month, we repeatedly measured in a fixed set of 10 apartments. The analysis comprised concentrations of 30 VOCs belonging to the groups of alkanes, cycloalkanes, aromatics, volatile halogenated hydrocarbons, and terpenes. The annual cycle for total VOC concentrations was observed at every site. Seasonality proved to be the most dominant pattern, but it may be modified by further factors, such as the city, the considered VOC component, and the type of the considered room. Highest concentrations occurred during the winter months and amount to approximately three to four times the summer burden. As seasonality may bias the results of health effect studies we fit a seasonal model to our measurements and develop a procedure for seasonal adjustment, which enables to roughly estimate the annual peak concentration utilizing one monthly observation. The seasonal pattern proved to be a general feature of indoor VOC concentrations and, therefore, this adjustment procedure may be generally applicable. For Leipzig, München, and Köln we present site-specific adjustment factors for indoor concentrations of aromatics, terpenes, and alkanes.

  4. The Shedler-Westen Assessment Procedure (SWAP): Evaluating Psychometric Questions about Its Reliability, Validity, and Impact of Its Fixed Score Distribution

    ERIC Educational Resources Information Center

    Blagov, Pavel S.; Bi, Wu; Shedler, Jonathan; Westen, Drew

    2012-01-01

    The Shedler-Westen Assessment Procedure (SWAP) is a personality assessment instrument designed for use by expert clinical assessors. Critics have raised questions about its psychometrics, most notably its validity across observers and situations, the impact of its fixed score distribution on research findings, and its test-retest reliability. We…

  5. An artificial test substrate for evaluating electron microscopic immunocytochemical labeling reactions.

    PubMed

    Gagne, G D; Miller, M F

    1987-08-01

    We describe an artificial substrate system for optimization of labeling parameters in electron microscope immunocytochemical studies. The system involves use of blocks of glutaraldehyde-polymerized BSA into which a desired antigen is incorporated by a simple soaking procedure. The resulting antigen-impregnated artificial substrate can then be fixed and embedded identically to a piece of tissue. The BSA substrate can also be dried and then sectioned for immunolabeling with or without chemical fixation and without exposing the antigen to dehydrating agents and embedding resins. The effects of various fixation and embedding procedures can thus be evaluated separately. Other parameters affecting immunocytochemical labeling, such as antibody and conjugate concentration, can also be evaluated. We used this system, along with immunogold labeling, to determine quantitatively the optimal fixation and embedding conditions for labeling of hepatitis B surface antigen (HbsAg), human IgG, and horseradish peroxidase. Using unfixed and unembedded HBsAg, we were able to detect antigen concentrations below 20 micrograms/ml. We have shown that it is not possible to label HBsAg within resin-embedded cells using conventional aldehyde fixation protocols and polyclonal antibodies.

  6. Procedures to handle inventory cluster plots that straddle two or more conditions

    Treesearch

    Jerold T. Hahn; Colin D. MacLean; Stanford L. Arner; William A. Bechtold

    1995-01-01

    We review the relative merits and field procedures for four basic plot designs to handle forest inventory plots that straddle two or more conditions, given that subplots will not be moved. A cluster design is recommended that combines fixed-area subplots and variable-radius plot (VRP) sampling. Each subplot in a cluster consists of a large fixed-area subplot for...

  7. Permanganate Fixation of Plant Cells

    PubMed Central

    Mollenhauer, Hilton H.

    1959-01-01

    In an evaluation of procedures explored to circumvent some of the problems of osmium tetroxide-fixation and methacrylate embedding of plant materials, excised segments of root tips of Zea mays were fixed for electron microscopy in potassium permanganate in the following treatment variations: unbuffered and veronal-acetate buffered solutions of 0.6, 2.0, and 5.0 per cent KMnO4 at pH 5.0, 6.0, 6.7, and 7.5, and temperatures of 2–4°C. and 22°C. After fixation the segments were dehydrated, embedded in epoxy resin, sectioned, and observed or photographed. The cells of the central region of the rootcap are described. The fixation procedures employing unbuffered solutions containing 2.0 to 5.0 per cent KMnO4 at a temperature of 22°C. gave particularly good preservation of cell structure and all membrane systems. Similar results were obtained using a solution containing 2.0 per cent KMnO4, buffered with veronal-acetate to pH 6.0, and a fixation time of 2 hours at 22°C. The fixation procedure utilizing veronal-acetate buffered, 0.6 per cent KMnO4 at 2–4°C. and pH 6.7 also gave relatively good preservation of most cellular constituents. However, preservation of the plasma membrane was not so good, nor was the intensity of staining so great, as that with the group of fixatives containing greater concentrations of KMnO4. The other fixation procedures did not give satisfactory preservation of fine structure. A comparison is made of cell structures as fixed in KMnO4 or OsO4. PMID:14423414

  8. Numerical procedures for the calculation of the stresses in monocoques III : calculation of the bending moments in fuselage frames

    NASA Technical Reports Server (NTRS)

    Hoff, N J; Libby, Paul A; Klein, Bertran

    1946-01-01

    This report deals with the calculation of the bending moments in and the distortions of fuselage rings upon which known concentrated and distributed loads are acting. In the procedure suggested, the ring is divided into a number of beams each having a constant radius of curvature. The forces and moments caused in the end sections of the beams by individual unit displacements of the end sections are listed in a table designated as the operations table in conformity with Southwell's nomenclature. The operations table and the external loads are equivalent to a set of linear equations. For their solution the following three procedures are presented: 1) Southwell's method of systematic relaxations. This is a step-by-step approximation procedure guided by the physical interpretation of the changes in the values of the unknown. 2) The growing unit procedure in which the individual beams are combined successively into beams of increasing length until finally the entire ring becomes a single beam. In each step of the procedure a set of not more than three simultaneous linear equations is solved. 3) Solution of the entire set of simultaneous equations by the methods of the matrix calculus. In order to demonstrate the manner in which the calculations may be carried out, the following numerical examples are worked out: 1) Curved beam with both its end sections rigidly fixed. The load is a concentrated force. 2) Egg-shape ring with symmetric concentrated loads. 3) Circular ring with antisymmetric concentrated loads and shear flow (torsion of the fuselage). 4) Same with V-braces incorporated in the ring. 5) Egg-shape ring with antisymmetric concentrated loads and shear flow (torsion of the fuselage). 6) Same with V-braces incorporated in the ring. The results of these calculations are checked, whenever possible, by calculations carried out according to known methods of analysis. The agreement is found to be good. The amount of work necessary for the solution of ring problems by the methods described in the present report is practically independent of the degree of redundancy of the structure. For this reason the methods are recommended for use particularly in problems of rings having one or more internal bracing elements.

  9. Dermal and inhalation acute toxic class methods: test procedures and biometric evaluations for the Globally Harmonized Classification System.

    PubMed

    Holzhütter, H G; Genschow, E; Diener, W; Schlede, E

    2003-05-01

    The acute toxic class (ATC) methods were developed for determining LD(50)/LC(50) estimates of chemical substances with significantly fewer animals than needed when applying conventional LD(50)/LC(50) tests. The ATC methods are sequential stepwise procedures with fixed starting doses/concentrations and a maximum of six animals used per dose/concentration. The numbers of dead/moribund animals determine whether further testing is necessary or whether the test is terminated. In recent years we have developed classification procedures for the oral, dermal and inhalation routes of administration by using biometric methods. The biometric approach assumes a probit model for the mortality probability of a single animal and assigns the chemical to that toxicity class for which the best concordance is achieved between the statistically expected and the observed numbers of dead/moribund animals at the various steps of the test procedure. In previous publications we have demonstrated the validity of the biometric ATC methods on the basis of data obtained for the oral ATC method in two-animal ring studies with 15 participants from six countries. Although the test procedures and biometric evaluations for the dermal and inhalation ATC methods have already been published, there was a need for an adaptation of the classification schemes to the starting doses/concentrations of the Globally Harmonized Classification System (GHS) recently adopted by the Organization for Economic Co-operation and Development (OECD). Here we present the biometric evaluation of the dermal and inhalation ATC methods for the starting doses/concentrations of the GHS and of some other international classification systems still in use. We have developed new test procedures and decision rules for the dermal and inhalation ATC methods, which require significantly fewer animals to provide predictions of toxicity classes, that are equally good or even better than those achieved by using the conventional LD(50)/LC(50) methods. In order to cope with rather narrow dose/concentration classes of the GHS we have, as in our previous publications, combined the outcome of all results that can be obtained during testing for the allocation to one of the defined toxicity classes of the GHS. Our results strongly recommend the deletion of the dermal LD(50) and the inhalation LC(50) test as regulatory tests and the adoption of the dermal and inhalation ATC methods as internationally accepted alternatives.

  10. Administration of anesthetic and analgesic prevent the suppression of many leukocyte responses following surgical castration and physical dehorning.

    PubMed

    Ballou, M A; Sutherland, M A; Brooks, T A; Hulbert, L E; Davis, B L; Cobb, C J

    2013-02-15

    The objectives of the current research were to determine the physiological effects and responses of many leukocytes following surgical castration and/(or) physical dehorning and the influence of anesthetics and analgesics in 3-month-old calves. Eighty 3-month-old Holstein bull calves were completely randomized to treatments in a 2 × 2 × 2 factorial arrangement with castration, dehorning, and anesthetic/analgesic as the main effects. Peripheral blood samples were collected just before (0) and 0.5, 1.5, 2.5, 4, 6, 24, and 72 h after the respective procedure(s) and analyzed for total leukocyte and differential counts, as well as plasma cortisol and haptoglobin concentrations. Blood from the 0, 0.5 and 24h collections were analyzed for many ex vivo leukocyte responses. Data were analyzed using a repeated measures analysis of variance with the fixed effects of treatment, time, and the interaction of treatment × time. Pre-planned contrasts were performed to determine the effect of (1) management procedure (castration and/(or) dehorning), (2) anesthetic/analgesic, and (3) were the management procedures additive. There were treatment × time interactions (P<0.05) on plasma cortisol and haptoglobin concentrations as well as for total leukocyte and neutrophil concentrations in blood. Castration and dehorning increased cortisol concentrations and the effect of the procedures was additive (P<0.02). Dehorning alone elicited a greater (P<0.05) cortisol response than castration alone. In contrast, the leukocytosis and neutrophilia was greater (P<0.01) among castrated calves. In addition, haptoglobin concentrations at 24h after castration were elevated (P<0.01) in calves that were castrated. Both castration and dehorning suppressed (P=0.04) many leukocyte responses including the secretion of tumor necrosis factor-α when whole blood cultures were stimulated with lipopolysaccharide, surface expression of L-selectin on peripheral blood neutrophils, and the oxidative burst intensity of peripheral blood neutrophils when co-cultured with an Escherichia coli. The effects of castration and dehorning on blood leukocyte counts or any of the leukocyte responses were not additive (P>0.23). Castration and dehorning effects of plasma haptoglobin concentrations tended (P=0.10) to be additive at 72 h after the procedure(s). Prior administration of local anesthetic and a systemic analgesic attenuated (P<0.001) the cortisol response and prevented (P=0.03) the observed leukocytosis, neutrophilia, and leukocyte suppression. These data suggest that calves should be castrated and dehorned on the same day rather than spreading them out across two days and calves should be administered pain relief prior to performing either procedure. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Relationship of follicle size and concentrations of estradiol among cows exhibiting or not exhibiting estrus during a fixed-time AI protocol

    USDA-ARS?s Scientific Manuscript database

    Cows exhibiting estrus near the time of fixed-time AI had greater pregnancy success than cows showing no estrus. The objective of this study was to determine the relationship between follicle size and peak estradiol concentration between cows that did or did not exhibit estrus during a fixed-time AI...

  12. PEST reduces bias in forced choice psychophysics.

    PubMed

    Taylor, M M; Forbes, S M; Creelman, C D

    1983-11-01

    Observers performed several different detection tasks using both the PEST adaptive psychophysical procedure and a fixed-level (method of constant stimuli) psychophysical procedure. In two experiments, PEST runs targeted at P (C) = 0.80 were immediately followed by fixed-level detection runs presented at the difficulty level resulting from the PEST run. The fixed-level runs yielded P (C) about 0.75. During the fixed-level runs, the probability of a correct response was greater when the preceding response was correct than when it was wrong. Observers, even highly trained ones, perform in a nonstationary manner. The sequential dependency data can be used to determine a lower bound for the observer's "true" capability when performing optimally; this lower bound is close to the PEST target, and well above the forced choice P (C). The observer's "true" capability is the measure used by most theories of detection performance. A further experiment compared psychometric functions obtained from a set of PEST runs using different targets with those obtained from blocks of fixed-level trials at different levels. PEST results were more stable across observers, performance at all but the highest signal levels was better with PEST, and the PEST psychometric functions had shallower slopes. We hypothesize that PEST permits the observer to keep track of what he is trying to detect, whereas in the fixed-level method performance is disrupted by memory failure. Some recently suggested "more virulent" versions of PEST may be subject to biases similar to those of the fixed-level procedures.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Sorption testing and generalized composite surface complexation models for determining uranium sorption parameters at a proposed in-situ recovery site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Raymond H.; Truax, Ryan A.; Lankford, David A.

    Solid-phase iron concentrations and generalized composite surface complexation models were used to evaluate procedures in determining uranium sorption on oxidized aquifer material at a proposed U in situ recovery (ISR) site. At the proposed Dewey Burdock ISR site in South Dakota, USA, oxidized aquifer material occurs downgradient of the U ore zones. Solid-phase Fe concentrations did not explain our batch sorption test results,though total extracted Fe appeared to be positively correlated with overall measured U sorption. Batch sorption test results were used to develop generalized composite surface complexation models that incorporated the full genericsorption potential of each sample, without detailedmore » mineralogiccharacterization. The resultant models provide U sorption parameters (site densities and equilibrium constants) for reactive transport modeling. The generalized composite surface complexation sorption models were calibrated to batch sorption data from three oxidized core samples using inverse modeling, and gave larger sorption parameters than just U sorption on the measured solidphase Fe. These larger sorption parameters can significantly influence reactive transport modeling, potentially increasing U attenuation. Because of the limited number of calibration points, inverse modeling required the reduction of estimated parameters by fixing two parameters. The best-fit models used fixed values for equilibrium constants, with the sorption site densities being estimated by the inversion process. While these inverse routines did provide best-fit sorption parameters, local minima and correlated parameters might require further evaluation. Despite our limited number of proxy samples, the procedures presented provide a valuable methodology to consider for sites where metal sorption parameters are required. Furthermore, these sorption parameters can be used in reactive transport modeling to assess downgradient metal attenuation, especially when no other calibration data are available, such as at proposed U ISR sites.« less

  14. Sorption testing and generalized composite surface complexation models for determining uranium sorption parameters at a proposed in-situ recovery site

    DOE PAGES

    Johnson, Raymond H.; Truax, Ryan A.; Lankford, David A.; ...

    2016-02-03

    Solid-phase iron concentrations and generalized composite surface complexation models were used to evaluate procedures in determining uranium sorption on oxidized aquifer material at a proposed U in situ recovery (ISR) site. At the proposed Dewey Burdock ISR site in South Dakota, USA, oxidized aquifer material occurs downgradient of the U ore zones. Solid-phase Fe concentrations did not explain our batch sorption test results,though total extracted Fe appeared to be positively correlated with overall measured U sorption. Batch sorption test results were used to develop generalized composite surface complexation models that incorporated the full genericsorption potential of each sample, without detailedmore » mineralogiccharacterization. The resultant models provide U sorption parameters (site densities and equilibrium constants) for reactive transport modeling. The generalized composite surface complexation sorption models were calibrated to batch sorption data from three oxidized core samples using inverse modeling, and gave larger sorption parameters than just U sorption on the measured solidphase Fe. These larger sorption parameters can significantly influence reactive transport modeling, potentially increasing U attenuation. Because of the limited number of calibration points, inverse modeling required the reduction of estimated parameters by fixing two parameters. The best-fit models used fixed values for equilibrium constants, with the sorption site densities being estimated by the inversion process. While these inverse routines did provide best-fit sorption parameters, local minima and correlated parameters might require further evaluation. Despite our limited number of proxy samples, the procedures presented provide a valuable methodology to consider for sites where metal sorption parameters are required. Furthermore, these sorption parameters can be used in reactive transport modeling to assess downgradient metal attenuation, especially when no other calibration data are available, such as at proposed U ISR sites.« less

  15. Balanced conscious sedation with intravenous induction and inhalational maintenance for patients requiring endoscopic and/or surgical procedures.

    PubMed

    Lahoud, G Y; Hopkins, P M

    2007-02-01

    The use of inhalation sedation with sub-anaesthetic concentrations of sevoflurane and nitrous oxide mixture is expected to reduce amounts of intravenous sedative drugs needed to produce a balanced sedation with the benefits of having reduced side-effects. Eighty-two patients requiring endoscopic and/or surgical procedures under conscious sedation and local anaesthesia were recruited for this pilot study. Conscious sedation was induced with a titrated dose of midazolam and propofol given intravenously until the clinical end-point of conscious sedation was achieved. Subsequently, during the procedure, the patient was asked to breathe sevoflurane 0.1-0.3% and a fixed ratio of 40% nitrous oxide in oxygen given through a face mask. In 78 patients (95.1%), the treatment was completed successfully. Patients were discharged back to the wards within 4-16 min (10.1) without significant side-effects. Treatment was satisfactorily accepted by 38 patients (48.7%) and considered excellent by 40 patients (51.3%). The use of titrated doses of intravenous sedative drugs for induction of conscious sedation followed by the use of low concentrations (0.1-0.3%) of sevoflurane combined with 40% nitrous oxide for maintenance of conscious sedation in patients requiring endoscopic and/or surgical procedures under local anaesthesia, has the potential advantages of reducing amounts of intravenous sedative drugs, less likelihood of problems from drug side-effects and fast recovery and discharge time. Further investigations to establish the technique are currently in progress.

  16. Relationship of follicle size and concentrations of estradiol among cows that do and do not exhibit estrus during a fixed-time AI protocol

    USDA-ARS?s Scientific Manuscript database

    Cows that exhibited estrus around the time of fixed-time AI had greater pregnancy success compared to cows that did not. The objective of this study was to determine the relationship between follicle size and peak estradiol concentration between cows that did or did not exhibit estrus during a fixed...

  17. Pullout repair of a medial meniscus posterior root tear using a FasT-Fix® all-inside suture technique.

    PubMed

    Kodama, Y; Furumatsu, T; Fujii, M; Tanaka, T; Miyazawa, S; Ozaki, T

    2016-11-01

    A medial meniscus posterior root tear (MMPRT) may increase the tibiofemoral contact pressure by decreasing the tibiofemoral contact area. Meniscal dysfunction induced by posterior root injury may lead to the development of osteoarthritic knees. Repair of a MMPRT can restore medial meniscus (MM) function and prevent knee osteoarthritis progression. Several surgical procedures have been reported for treating a MMPRT. However, these procedures are associated with several technical difficulties. Here, we describe a technique to stabilize a torn MM posterior root using the FasT-Fix ® all-inside meniscal suture device and a new aiming device. The uncut free-end of the FasT-Fix ® suture can be used as a thread for transtibial pullout repair. Our procedure might help overcome the technical difficulties in arthroscopic treatment of a MMPRT. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  18. Comparative field study: impact of laboratory assay variability on the assessment of recombinant factor IX Fc fusion protein (rFIXFc) activity.

    PubMed

    Sommer, Jurg M; Buyue, Yang; Bardan, Sara; Peters, Robert T; Jiang, Haiyan; Kamphaus, George D; Gray, Elaine; Pierce, Glenn F

    2014-11-01

    Due to variability in the one-stage clotting assay, the performance of new factor IX (FIX) products should be assessed in this assay. The objective of this field study was to evaluate the accuracy of measuring recombinant FIX Fc fusion protein (rFIXFc) activity in clinical haemostasis laboratories using the one-stage clotting assay. Human haemophilic donor plasma was spiked with rFIXFc or BeneFIX® at 0.80, 0.20, or 0.05 IU/ml based on label potency. Laboratories tested blinded samples using their routine one-stage assay and in-house FIX plasma standard. The mean spike recoveries for BeneFIX (n=30 laboratories) were 121 %, 144 %, and 168 % of expected at nominal 0.80, 0.20, and 0.05 IU/ml concentrations, respectively. Corresponding rFIXFc spike recoveries were 88 %, 107 %, and 132 % of expected, respectively. All BeneFIX concentrations were consistently overestimated by most laboratories. rFIXFc activity was reagent-dependent; ellagic acid and silica gave higher values than kaolin, which underestimated rFIXFc. BeneFIX demonstrated significantly reduced chromogenic assay activity relative to one-stage assay results and nominal activity, while rFIXFc activity was close to nominal activity at three concentrations with better dilution linearity than the typical one-stage assay. In conclusion, laboratory- and reagent-specific assay variabilities were revealed, with progressively higher variability at lower FIX concentrations. Non-parallelism against the FIX plasma standard was observed in all one-stage assays with rFIXFc and BeneFIX, leading to significant overestimation of FIX activity at lower levels and generally high inter-laboratory variability. Compared to the accuracy currently achieved in clinical laboratories when measuring other rFIX products, most laboratories measured rFIXFc activity with acceptable accuracy and reliability using routine one-stage assay methods and commercially available plasma standards.

  19. On the equivalence of the dual-wavelength and polarimetric equations for estimation of the raindrop size distribution

    NASA Technical Reports Server (NTRS)

    Meneghini, Robert; Liao, Liang

    2006-01-01

    In writing the integral equations for the median mass diameter and particle concentration, or comparable parameters of the raindrop size distribution, it is apparent that when attenuation effects are included, the forms of the equations for polarimetric and dual wavelength radars are identical. In both sets of equations, differences in the backscattering and extinction cross sections appear: in the polarimetric equations, the differences are taken with respect polarization at a fixed frequency while for the dual wavelength equations, the differences are taken with respect to wavelength at a fixed polarization. Because the forms of the equations are the same, the ways in which they can be solved are similar as well. To avoid instabilities in the forward recursion procedure, the equations can be expressed in the form of a final-value. Solving the equations in this way traditionally has required estimates of the path attenuations to the final gate: either the attenuations at horizontal and vertical polarizations at the same frequency or attenuations at two frequencies with the same polarization. This has been done for dual-frequency (air/spaceborne case) and polarimetric radars by the respective use of the surface reference technique and the differential phase shift. An alternative to solving the constrained version of the equations is an iterative procedure recently proposed in which independent estimates of path attenuation are not required. Although the procedure has limitations, it appears to be quite useful. Simulations of the retrievals help clarify the relationship between the constrained and unconstrained approaches and their application to the polarimetric and dual-wavelength equations.

  20. Exposure chain of urban air PM 2.5—associations between ambient fixed site, residential outdoor, indoor, workplace and personal exposures in four European cities in the EXPOLIS-study

    NASA Astrophysics Data System (ADS)

    Kousa, Anu; Oglesby, Lucy; Koistinen, Kimmo; Künzli, Nino; Jantunen, Matti

    In the EXPOLIS study personal exposures and microenvironment levels of air pollutants from 50-201 urban adult (25-55 yr) participants were measured in six European cities during 1 yr from autumn 1996 to winter 1997-98. This paper presents the associations between the personal PM 2.5 exposures, microenvironment (residential indoor, residential outdoor and workplace indoor) and ambient fixed site concentrations measured in Helsinki (Finland), Basel (Switzerland), Prague (Czech Republic) and Athens (Greece). Considering the whole chain from ambient fixed site to residential outdoor, residential indoor and personal leisure time (non-working hours) exposure, the correlations were highest between personal leisure time exposures and residential indoor concentrations (non-environmental tobacco smoke (ETS): Pearson r=0.72-0.92, ETS included: r=0.82-0.86) except in Athens, where the correlation between residential indoor and outdoor air was highest (non-ETS: r=0.82, ETS included: r=0.68)). Unfortunately, ambient fixed site PM 2.5 concentrations were measured continuously only in Helsinki. Ambient fixed site PM 2.5 concentrations correlated quite well with residential outdoor concentrations ( r=0.90), and also with residential indoor (non-ETS) concentrations ( r=0.80), but concentrations measured at ambient fixed site monitors were poor predictors of personal exposures to PM 2.5. They were particularly poor predictors of personal workday exposures (non-ETS: r=0.34, ETS included: r=0.25), but considerably better for personal leisure time exposures (non-ETS: r=0.69, ETS included: r=0.54). According to log-linear regression models combined from all centres of non-ETS-exposed participants, residential indoor concentrations explained 76% of personal leisure time PM 2.5 exposure variation and workplace indoor concentrations explained 66% of the workday exposure variation.

  1. Measuring factor IX activity of nonacog beta pegol with commercially available one-stage clotting and chromogenic assay kits: a two-center study.

    PubMed

    Bowyer, A E; Hillarp, A; Ezban, M; Persson, P; Kitchen, S

    2016-07-01

    Essentials Validated assays are required to precisely measure factor IX (FIX) activity in FIX products. N9-GP and two other FIX products were assessed in various coagulation assay systems at two sites. Large variations in FIX activity measurements were observed for N9-GP using some assays. One-stage and chromogenic assays accurately measuring FIX activity for N9-GP were identified. Background Measurement of factor IX activity (FIX:C) with activated partial thromboplastin time-based one-stage clotting assays is associated with a large degree of interlaboratory variation in samples containing glycoPEGylated recombinant FIX (rFIX), i.e. nonacog beta pegol (N9-GP). Validation and qualification of specific assays and conditions are necessary for the accurate assessment of FIX:C in samples containing N9-GP. Objectives To assess the accuracy of various one-stage clotting and chromogenic assays for measuring FIX:C in samples containing N9-GP as compared with samples containing rFIX or plasma-derived FIX (pdFIX) across two laboratory sites. Methods FIX:C, in severe hemophilia B plasma spiked with a range of concentrations (from very low, i.e. 0.03 IU mL(-1) , to high, i.e. 0.90 IU mL(-1) ) of N9-GP, rFIX (BeneFIX), and pdFIX (Mononine), was determined at two laboratory sites with 10 commercially available one-stage clotting assays and two chromogenic FIX:C assays. Assays were performed with a plasma calibrator and different analyzers. Results A high degree of variation in FIX:C measurement was observed for one-stage clotting assays for N9-GP as compared with rFIX or pdFIX. Acceptable N9-GP recovery was observed in the low-concentration to high-concentration samples tested with one-stage clotting assays using SynthAFax or DG Synth, or with chromogenic FIX:C assays. Similar patterns of FIX:C measurement were observed at both laboratory sites, with minor differences probably being attributable to the use of different analyzers. Conclusions These results suggest that, of the reagents tested, FIX:C in N9-GP-containing plasma samples can be most accurately measured with one-stage clotting assays using SynthAFax or DG Synth, or with chromogenic FIX:C assays. © 2016 International Society on Thrombosis and Haemostasis.

  2. Pharmacokinetics and bioequivalence study of a fixed dose combination of rabeprazole and itopride in healthy Indian volunteers.

    PubMed

    Sahoo, Bijay Kumar; Das, Ayan; Agarwal, Sangita; Bhaumik, Uttam; Bose, Anirbandeep; Ghosh, Debotri; Roy, Bikash; Pal, Tapan Kumar

    2009-01-01

    The aim of the present study was to compare the pharmacokinetics of rabeprazole (CAS 117976-89-3) and itopride (CAS 122898-67-3) after oral administration of a rabeprazole (20 mg)-itopride (150 mg) fixed dose combination (FDC) in healthy human volunteers. The bioequivalence of two formulations (test and reference) was determined in 12 healthy Indian male volunteers (age: 25.25 +/- 4.69 years; weight: 60.50 +/- 5.04 kg) in a randomized, single-dose, two-period, two-treatment crossover study. Both formulations were administered orally as a single dose, with the treatments separated by a washout period of 1 week. Rabeprazole and itopride plasma levels were determined by a validated HPLC method using UV detection. The formulations were compared using the pharmacokinetic parameters area under the plasma concentration-time curve (AUC(0-t)), area under the plasma concentration-time curve from zero to infinity (AUC(0-infinity)) and peak plasma concentration (Cmax). General linear model (GLM) procedures were used in which sources of variation were subject, treatment and period. The results indicated that there were no statistically significant differences (P > 0.05) between the logarithmically transformed AUC(0-infinity) and Cmax values between test and reference formulation. The 90% confidence interval for the ratio of the logarithmically transformed AUC(0-t), AUC(0-infinity) and Cmax were within the bioequivalence limits of 0.8-1.25 and the relative bioavailability of rabeprazole and itopride test and reference formulations was 98.24 and 93.65%, respectively.

  3. Rotary transformer design with fixed magnetizing and/or leakage inductances

    NASA Technical Reports Server (NTRS)

    Stuart, T. A.; King, R. J.; Shamseddin, H.

    1985-01-01

    A design algorithm is considered for transformers that must transfer electric power across a rotating interface. Among other features, this procedure allows the designer to minimize either weight or losses for either a fixed magnetizing inductance or a fixed leakage inductance. Numerical results are included to indicate the design trade-offs between various parameters.

  4. Adsorption study of a macro-RAFT agent onto SiO2-coated Gd2O3:Eu3+ nanorods: Requirements and limitations

    NASA Astrophysics Data System (ADS)

    Zou, Hua; Melro, Liliana; de Camargo Chaparro, Thaissa; de Souza Filho, Isnaldi Rodrigues; Ananias, Duarte; Bourgeat-Lami, Elodie; dos Santos, Amilton Martins; Barros-Timmons, Ana

    2017-02-01

    The use of a macromolecular RAFT (macro-RAFT) agent to encapsulate anisotropic nano-objects via emulsion polymerization is an emerging route to prepare polymer/inorganic colloidal nanocomposites. However, a number of requirements have to be fulfilled. This work aims at highlighting the effects of the preparative procedure and dispersion method on the amount of macro-RAFT agent adsorbed onto SiO2-coated Gd2O3:Eu3+ nanorods. The adsorption of macro-RAFT agent was studied using the depletion method with UV-vis spectrophotometry. Measurements were performed at a fixed concentration of nanorods and varying concentrations of the macro-RAFT agent in aqueous dispersion at room temperature. The adsorption isotherms showed that for the same initial macro-RAFT agent concentration, the highest adsorption capacity of the macro-RAFT agent on nanorods was usually achieved for non-calcined thin SiO2-coated nanorods under mild bath sonication.

  5. Factors influencing discomfort during anterior ultrasound-guided injection for hip arthrography.

    PubMed

    Hsu, Yi-Chih; Wu, Yu-Cheng; Kao, Hao-Lun; Pan, Ru-Yu; Lee, Meei-Shyuan; Huang, Guo-Shu

    2013-09-01

    Although ultrasound (US)-guided injection techniques for magnetic resonance arthrography of the hip have been used with increasing frequency to diagnose internal joint derangements, little is known about patient tolerance, which is relevant information for patients. The objective of this study was to evaluate prospectively the association between possible influencing factors and discomfort felt during the performance of anterior US-guided injection techniques targeting the femoral head-neck junction during hip arthrography. Forty-four consecutive patients (21 women and 23 men; mean age, 41 years) undergoing magnetic resonance hip arthrography were sequentially assigned to receive injection alternating between fixed and freehand US-guided injection. Discomfort was assessed using a visual analog scale and relative ratings. Patient body mass index, extra-articular contrast leakage, the duration of the procedure, the needle advancement distance, and the fixed trajectory of the needle were assessed. Pearson's correlation coefficients and multiple logistic regression analysis were used to determine the association. Puncture was successfully accomplished in all cases, and no relevant complications were reported. The only significant relationships were between discomfort and the time required for needle manipulation (r = 0.8) and fixed US-guided injection (r = 0.6; p < 0.001). Compared with the freehand technique, the fixed technique resulted in significantly less pain and took significantly less time to perform (p < 0.001). The procedure time during needle manipulation in the fixed US-guided injections (4.0 ± 0.9 seconds) was significantly less than that in the freehand US-guided injections (19.4 ± 17.6 seconds; p < 0.001). No significant relationships were found between discomfort and other parameters (r < 0.3, p > 0.05). The procedure time appears to be the most important factor influencing patient discomfort. Fixed US-guided injection is a time-saving technique that alleviates procedure-related discomfort. Copyright © 2013. Published by Elsevier B.V.

  6. Time-to-isolation guided titration of freeze duration in 3rd generation short-tip cryoballoon pulmonary vein isolation - Comparable clinical outcome and shorter procedure duration.

    PubMed

    Pott, Alexander; Kraft, Christoph; Stephan, Tilman; Petscher, Kerstin; Rottbauer, Wolfgang; Dahme, Tillman

    2018-03-15

    The optimal freeze duration in cryoballoon pulmonary vein isolation (PVI) is unknown. The 3rd generation cryoballoon facilitates observation of the time-to-isolation (TTI) and thereby enables individualized cryoenergy titration. To evaluate the efficacy of an individualized freeze duration we compared the clinical outcome of patients treated with a TTI-guided ablation protocol to the outcome of patients treated with a fixed ablation protocol. We compared 100 patients treated with the 3rd generation cryoballoon applying a TTI-based protocol (TTI group) to 100 patients treated by a fixed freeze protocol (fixed group). In the fixed group a 240s freeze cycle was followed by a 240s bonus freeze after acute PV isolation. In the TTI group freeze duration was 180s if TTI was ≥30s and reduced to only 120s, if TTI was <30s. In case of a TTI >60s a 180s bonus freeze was applied. Freedom from atrial arrhythmia recurrence off class I/III antiarrhythmic drugs after one year was not different between the TTI group (73.6%) and the fixed group (75.7%; p=0.75). Mean procedure duration was 85.8±27.3min in the TTI group compared to 115.7±27.1min in the fixed group (p<0.001). Mean fluoroscopy time was 17.5±6.6min in the TTI group and 22.5±9.8min in the fixed group (p<0.001). TTI-guided cryoenergy titration leads to reduced procedure duration and fluoroscopy time and appears to be as effective as a fixed ablation strategy. A single 2-minute freeze seems to be sufficient in case of short TTI. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  7. 77 FR 50049 - Procedures To Govern the Use of Satellite Earth Stations on Board Vessels in the 5925-6425 MHz...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-20

    ...-space) frequency band, operating with Geostationary Satellite Orbit (GSO) Satellites in the Fixed... with Geostationary Orbit (GSO) Satellites in the Fixed- Satellite Service. (a) The following ongoing...

  8. Determination of the lowest concentrations of aldehyde fixatives for completely fixing various cellular structures by real-time imaging and quantification.

    PubMed

    Zeng, Fangfa; Yang, Wen; Huang, Jie; Chen, Yuan; Chen, Yong

    2013-05-01

    The effectiveness of fixatives for fixing biological specimens has long been widely investigated. However, the lowest concentrations of fixatives needed to completely fix whole cells or various cellular structures remain unclear. Using real-time imaging and quantification, we determined the lowest concentrations of glutaraldehyde (0.001-0.005, ~0.005, 0.01-005, 0.01-005, and 0.01-0.1 %) and formaldehyde/paraformaldehyde (0.01-0.05, ~0.05, 0.5-1, 1-1.5, and 0.5-1 %) required to completely fix focal adhesions, cell-surface particles, stress fibers, the cell cortex, and the inner structures of human umbilical vein endothelial cells within 20 min. With prolonged fixation times (>20 min), the concentration of fixative required to completely fix these structures will shift to even lower values. These data may help us understand and optimize fixation protocols and understand the potential effects of the small quantities of endogenously generated aldehydes in human cells. We also determined the lowest concentration of glutaraldehyde (0.5 %) and formaldehyde/paraformaldehyde (2 %) required to induce cell blebbing. We found that the average number and size of the fixation-induced blebs per cell were dependent on both fixative concentration and cell spread area, but were independent of temperature. These data provide important information for understanding cell blebbing, and may help optimize the vesiculation-based technique used to isolate plasma membrane by suggesting ways of controlling the number or size of fixation-induced cell blebs.

  9. Dissolution of cement, root caries, fracture, and retrofit of post and cores.

    PubMed

    Rosen, H

    1998-10-01

    Fixed partial denture abutments severely damaged by dental caries or fracture present a challenge to the dentist. The fixed partial denture may need to be removed for endodontic treatment with post and core fabrication. Frequently, the existing fixed partial denture can be recycled as a provisional restoration. Retrofitting the post and core greatly improves the stabilization of the interim as well as the remake of the definitive fixed partial denture. This article describes a chair side procedure for retrofitting posts and cores and, at the same appointment, converting the original fixed partial denture to an effective provisional restoration.

  10. Multidisciplinary approach to restoring anterior maxillary partial edentulous area using an IPS Empress 2 fixed partial denture: a clinical report.

    PubMed

    Dundar, Mine; Gungor, M Ali; Cal, Ebru

    2003-04-01

    Esthetics is a major concern during restoration of anterior partial edentulous areas. All-ceramic fixed partial dentures may provide better esthetics and biocompatibility in the restoration of anterior teeth. This clinic report describes a multidisciplinary approach and treatment procedures with an IPS Empress 2 fixed partial denture to restore missing anterior teeth.

  11. Determination of inorganic arsenic species in natural waters--benefits of separation and preconcentration on ion exchange and hybrid resins.

    PubMed

    Ben Issa, Nureddin; Rajaković-Ognjanović, Vladana N; Jovanović, Branislava M; Rajaković, Ljubinka V

    2010-07-19

    A simple method for the separation and determination of inorganic arsenic (iAs) species in natural and drinking water was developed. Procedures for sample preparation, separation of As(III) and As(V) species and preconcentration of the total iAs on fixed bed columns were defined. Two resins, a strong base anion exchange (SBAE) resin and a hybrid (HY) resin were utilized. The inductively-coupled plasma-mass spectrometry method was applied as the analytical method for the determination of the arsenic concentration in water. The governing factors for the ion exchange/sorption of arsenic on resins in a batch and a fixed bed flow system were analyzed and compared. Acidity of the water, which plays an important role in the control of the ionic or molecular forms of arsenic species, was beneficial for the separation; by adjusting the pH values to less than 8.00, the SBAE resin separated As(V) from As(III) in water by retaining As(V) and allowing As(III) to pass through. The sorption activity of the hydrated iron oxide particles integrated into the HY resin was beneficial for bonding of all iAs species over a wide range of pH values from 5.00 to 11.00. The resin capacities were calculated according to the breakthrough points in a fixed bed flow system. At pH 7.50, the SBAE resin bound more than 370 microg g(-1) of As(V) while the HY resin bound more than 4150 microg g(-1) of As(III) and more than 3500 microg g(-1) of As(V). The high capacities and selectivity of the resins were considered as advantageous for the development and application of two procedures, one for the separation and determination of As(III) (with SBAE) and the other for the preconcentration and determination of the total arsenic (with HY resin). Methods were established through basic analytical procedures (with external standards, certified reference materials and the standard addition method) and by the parallel analysis of some samples using the atomic absorption spectrometry-hydride generation technique. The analytical properties of both procedures were similar: the limit of detection was 0.24 microg L(-1), the limit of quantification was 0.80 microg L(-1) and the relative standard deviations for samples with a content of arsenic from 10.00 to 300.0 microg L(-1) ranged from 1.1 to 5.8%. The interference effects of anions commonly found in water and some organic species which can be present in water were found to be negligible. Verification with certified reference materials proved that the experimental concentrations found for model solutions and real samples were in agreement with the certified values. 2010 Elsevier B.V. All rights reserved.

  12. Performance of time-varying predictors in multilevel models under an assumption of fixed or random effects.

    PubMed

    Baird, Rachel; Maxwell, Scott E

    2016-06-01

    Time-varying predictors in multilevel models are a useful tool for longitudinal research, whether they are the research variable of interest or they are controlling for variance to allow greater power for other variables. However, standard recommendations to fix the effect of time-varying predictors may make an assumption that is unlikely to hold in reality and may influence results. A simulation study illustrates that treating the time-varying predictor as fixed may allow analyses to converge, but the analyses have poor coverage of the true fixed effect when the time-varying predictor has a random effect in reality. A second simulation study shows that treating the time-varying predictor as random may have poor convergence, except when allowing negative variance estimates. Although negative variance estimates are uninterpretable, results of the simulation show that estimates of the fixed effect of the time-varying predictor are as accurate for these cases as for cases with positive variance estimates, and that treating the time-varying predictor as random and allowing negative variance estimates performs well whether the time-varying predictor is fixed or random in reality. Because of the difficulty of interpreting negative variance estimates, 2 procedures are suggested for selection between fixed-effect and random-effect models: comparing between fixed-effect and constrained random-effect models with a likelihood ratio test or fitting a fixed-effect model when an unconstrained random-effect model produces negative variance estimates. The performance of these 2 procedures is compared. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  13. Model Comparison of Nonlinear Structural Equation Models with Fixed Covariates.

    ERIC Educational Resources Information Center

    Lee, Sik-Yum; Song, Xin-Yuan

    2003-01-01

    Proposed a new nonlinear structural equation model with fixed covariates to deal with some complicated substantive theory and developed a Bayesian path sampling procedure for model comparison. Illustrated the approach with an illustrative example using data from an international study. (SLD)

  14. 75 FR 15392 - Satellite License Procedures

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-29

    ... earth station applications must be filed electronically through the International Bureau Filing System... space radio- communication service other than the Fixed Satellite Service. Fixed earth station. An earth... revisions to its satellite and earth station licensing rules. The intended purpose of this proceeding is to...

  15. Serum thyroxine concentrations following fixed-dose radioactive iodine treatment in hyperthyroid cats: 62 cases (1986-1989)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meric, S.M.; Rubin, S.I.

    The medical records of 62 hyperthyroid cats treated with a fixed dose of 4 mCi of radioactive iodine (131I) were reviewed. In 60 cats, serum thyroxine concentrations were determined after treatment, allowing evaluation of treatment success. Eighty-four percent of the cats had normal serum thyroxine concentrations after treatment. Five of the 60 cats (8%) remained hyperthyroxinemic after treatment. Five cats (8%) were hypothyroxinemic when evaluated within 60 days of treatment. Three of these cats had normal serum thyroxine concentrations 6 months after treatment, and none had clinical signs of hypothyroidism. The administration of a fixed dose of 4 mCi ofmore » 131I was determined to be an effective treatment for feline hyperthyroidism.« less

  16. Oil refinery wastewater treatment using coupled electrocoagulation and fixed film biological processes

    NASA Astrophysics Data System (ADS)

    Pérez, Laura S.; Rodriguez, Oscar M.; Reyna, Silvia; Sánchez-Salas, José Luis; Lozada, J. Daniel; Quiroz, Marco A.; Bandala, Erick R.

    2016-02-01

    Oil refinery wastewater was treated using a coupled treatment process including electrocoagulation (EC) and a fixed film aerobic bioreactor. Different variables were tested to identify the best conditions using this procedure. After EC, the effluent was treated in an aerobic biofilter. EC was capable to remove over 88% of the overall chemical oxygen demand (COD) in the wastewater under the best working conditions (6.5 V, 0.1 M NaCl, 4 electrodes without initial pH adjustment) with total petroleum hydrocarbon (TPH) removal slightly higher than 80%. Aluminum release from the electrodes to the wastewater was found an important factor for the EC efficiency and closely related with several operational factors. Application of EC allowed to increase the biodegradability of the sample from 0.015, rated as non-biodegradable, up to 0.5 widely considered as biodegradable. The effluent was further treated using an aerobic biofilter inoculated with a bacterial consortium including gram positive and gram negative strains and tested for COD and TPH removal from the EC treated effluent during 30 days. Cell count showed the typical bacteria growth starting at day three and increasing up to a maximum after eight days. After day eight, cell growth showed a plateau which agreed with the highest decrease on contaminant concentration. Final TPHs concentration was found about 600 mgL-1 after 30 days whereas COD concentration after biological treatment was as low as 933 mgL-1. The coupled EC-aerobic biofilter was capable to remove up to 98% of the total TPH amount and over 95% of the COD load in the oil refinery wastewater.

  17. [Measurement of airborne asbestos fibers on railroad rolling stock].

    PubMed

    Camilucci, L; Catasta, P F; Chiappino, G; Governa, M; Munafò, E; Verduchi, P; Paba, G

    2000-01-01

    In February 1995 the Italian Railways Health Department set up a special study group in order to assess the effectiveness of the measures adopted against hazards due to the presence of asbestos in rolling stock currently in use on the rail network. The group set up specific procedures for sampling and analysis, on the basis of the criteria fixed for civil buildings in Ministerial Decree of 6/9/94, which was subsequently applied to rolling stock by Ministerial Decree of 26/10/95. In accordance with these procedures the study group carried out environmental studies via test runs programmed by the Railways Technical Departments, on trains made up of different types of vehicles. Insulated, completely or partially deinsulated and originally non-insulated vehicles were studied. Samples were analysed via scanning electron microscopy (SEM) with elementary dispersion X spectroscopy (EDXS) carried out by highly qualified public laboratories (ISPESL--National Institute for Prevention and Work Safety, ARPA--Regional Environmental Protection Agency, CRA--Veneto Region, University Departments). Altogether, from the start of the programme up to September 1998, 1464 samples in 170 test runs on 619 rolling stock vehicles were examined. These involved 83 locomotives, 83 electric rail-cars and 453 carriages. The results showed that in over 99% of the samples the fibre concentrations were below 2 fibres/litre, which is the value fixed by law for buildings and rail vehicles in order to qualify for effective decontamination status. Values exceeding 2 fibres/litre were found in only 4 vehicles, which were withdrawn or blocked for further checks. As a precaution, 18 vehicles where concentrations over 1 but less than 2 fibres/litre were found, were also blocked and their return to service has been postponed for further checks and analyses until the results show concentrations below 1 fibre/litre. Environmental analyses carried out up to the present indicate an overall situation comparable to that usually found in the general environmental without any asbestos dispersion sources. Surveillance and investigations are still under way in order to achieve the aims of the safety programme set up by the Italian Railways to ensure health and environmental protection.

  18. Determination of the mass transfer limiting step of dye adsorption onto commercial adsorbent by using mathematical models.

    PubMed

    Marin, Pricila; Borba, Carlos Eduardo; Módenes, Aparecido Nivaldo; Espinoza-Quiñones, Fernando R; de Oliveira, Silvia Priscila Dias; Kroumov, Alexander Dimitrov

    2014-01-01

    Reactive blue 5G dye removal in a fixed-bed column packed with Dowex Optipore SD-2 adsorbent was modelled. Three mathematical models were tested in order to determine the limiting step of the mass transfer of the dye adsorption process onto the adsorbent. The mass transfer resistance was considered to be a criterion for the determination of the difference between models. The models contained information about the external, internal, or surface adsorption limiting step. In the model development procedure, two hypotheses were applied to describe the internal mass transfer resistance. First, the mass transfer coefficient constant was considered. Second, the mass transfer coefficient was considered as a function of the dye concentration in the adsorbent. The experimental breakthrough curves were obtained for different particle diameters of the adsorbent, flow rates, and feed dye concentrations in order to evaluate the predictive power of the models. The values of the mass transfer parameters of the mathematical models were estimated by using the downhill simplex optimization method. The results showed that the model that considered internal resistance with a variable mass transfer coefficient was more flexible than the other ones and this model described the dynamics of the adsorption process of the dye in the fixed-bed column better. Hence, this model can be used for optimization and column design purposes for the investigated systems and similar ones.

  19. Study of tribological properties of natural rubber containing carbon nanotubes and carbon black as hybrid fillers

    NASA Astrophysics Data System (ADS)

    Harea, Evghenii; Stoček, Radek; Storozhuk, Liudmyla; Sementsov, Yurii; Kartel, Nikolai

    2018-04-01

    Dry friction and wear properties of natural rubber (NR), containing multi-walled carbon nanotubes (MWCNT) and carbon black (CB), were investigated. Natural rubber (NR)-based composites containing all common additives and curatives, and a fixed amount (30 phr—parts per 100 rubber by weight) of hybrid fillers (MWCNT x + CB30-x ) were prepared by simple mixing procedure and tested. The main goal was to study the behaviours of composites at different tribological testing conditions, such as friction speed and normal load. It was found that with an increase of concentration of MWCNT from x = 0 phr to x = 5 phr in studied composites, there was a decrease in the coefficient of friction (COF) with no significant change in wear in the framework of each used combination of testing parameters. Generally, higher friction speed at certain normal force led to the increase of COF of all the samples and wear reflected deliberate value fluctuation. Also, it was established that considerable growth of wear and unexpected reducing of friction coefficient ensued from increasing of applied load for every fixed sliding speed.

  20. Online, absolute quantitation of propranolol from spatially distinct 20-μm and 40-μm dissections of brain, liver, and kidney thin tissue sections by laser microdissection – liquid vortex capture – mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kertesz, Vilmos; Vavrek, Marissa; Freddo, Carol

    Here, spatial resolved quantitation of chemical species in thin tissue sections by mass spectrometric methods has been constrained by the need for matrix-matched standards or other arduous calibration protocols and procedures to mitigate matrix effects (e.g., spatially varying ionization suppression). Reported here is the use of laser cut and drop sampling with a laser microdissection-liquid vortex capture electrospray ionization tandem mass spectrometry (LMD-LVC/ESI-MS/MS) system for online and absolute quantitation of propranolol in mouse brain, kidney, and liver thin tissue sections of mice administered with the drug at a 7.5 mg/kg dose, intravenously. In this procedure either 20 μm x 20more » μm or 40 μm x 40 μm tissue microdissections were cut and dropped into the flowing solvent of the capture probe. During transport to the ESI source drug related material was completely extracted from the tissue into the solvent, which contained a known concentration of propranolol-d 7 as an internal standard. This allowed absolute quantitation to be achieved with an external calibration curve generated from standards containing the same fixed concentration of propranolold-d 7 and varied concentrations of propranolol. Average propranolol concentrations determined with the laser cut and drop sampling method closely agreed with concentration values obtained from 2.3 mm diameter tissue punches from serial sections that were extracted and quantified by HPLC/ESI-MS/MS measurements. In addition, the relative abundance of hydroxypropranolol glucuronide metabolites were recorded and found to be consistent with previous findings.« less

  1. [Binding properties of components removable from dental base plate, analysed by Fourier-Transform Surface Plasmon Resonance (FT-SPR) method].

    PubMed

    Bakó, József; Kelemen, Máté; Szalóki, Melinda; Vitályos, Géza; Radics, Tünde; Hegedüs, Csaba

    2015-03-01

    In parallel with the emergence of new dental materials the number of allergic diseases is continuously increasing. Extremely small quantities of the allergens are capable to inducing an allergic reaction. Therefore it is particularly important to examine these materials as antigens and investigate their binding properties to proteins (e.g. formaldehyde, methacrylic acid, benzoyl-peroxide...). The Fourier Transform Surface Plasmon Resonance Spectroscopy (FT-SPR) is a suitable examination method for this type of procedure. FT-SPR measurement is performed at a fixed angel of incident light, and reflectivity is measured over a range of wavelength in the near infrared. The advantages of this method are the outstanding sensitivity, the label-free detection capability and the possibility of the real-time testing procedure. Formaldehyde and methacrylic acid are among the most common dental allergens. In our study we examined these molecules by FT-SPR spectroscopy. The aim of this work was to investigate the suitability of this method to the detection of these materials, with special focuses on the analysis and evaluation concentration-dependent measurements. Different concentrations (0.01 %-0.2%) of formaldehyde and methacrylic acid solutions were measured. The individual spectra were measured for all of the solutions, and calibration curves were calculated for the materials for the possibility of the determination of an unknown concentration. The results confirmed that the method is theoretically capable to detect hundred-thousandths scale concentration-changes in the solution flowing above the SPR-chip. The concentration-dependent studies had proved that the method capable to measure directly these materials and can provide appropriate calibration for quantitative determination. These experiments show the broad applicability of the FT-SPR method, which can greatly facilitate the mapping and understanding of biomolecular interactions in the future.

  2. Online, absolute quantitation of propranolol from spatially distinct 20-μm and 40-μm dissections of brain, liver, and kidney thin tissue sections by laser microdissection – liquid vortex capture – mass spectrometry

    DOE PAGES

    Kertesz, Vilmos; Vavrek, Marissa; Freddo, Carol; ...

    2016-05-23

    Here, spatial resolved quantitation of chemical species in thin tissue sections by mass spectrometric methods has been constrained by the need for matrix-matched standards or other arduous calibration protocols and procedures to mitigate matrix effects (e.g., spatially varying ionization suppression). Reported here is the use of laser cut and drop sampling with a laser microdissection-liquid vortex capture electrospray ionization tandem mass spectrometry (LMD-LVC/ESI-MS/MS) system for online and absolute quantitation of propranolol in mouse brain, kidney, and liver thin tissue sections of mice administered with the drug at a 7.5 mg/kg dose, intravenously. In this procedure either 20 μm x 20more » μm or 40 μm x 40 μm tissue microdissections were cut and dropped into the flowing solvent of the capture probe. During transport to the ESI source drug related material was completely extracted from the tissue into the solvent, which contained a known concentration of propranolol-d 7 as an internal standard. This allowed absolute quantitation to be achieved with an external calibration curve generated from standards containing the same fixed concentration of propranolold-d 7 and varied concentrations of propranolol. Average propranolol concentrations determined with the laser cut and drop sampling method closely agreed with concentration values obtained from 2.3 mm diameter tissue punches from serial sections that were extracted and quantified by HPLC/ESI-MS/MS measurements. In addition, the relative abundance of hydroxypropranolol glucuronide metabolites were recorded and found to be consistent with previous findings.« less

  3. Tree form quotients as variables in volume estimation.

    Treesearch

    Gerald E. Hoyer

    1985-01-01

    The study reviews Hohenadl's procedure for defining form quotients and tree volume from diameters measured at fixed proportions of total tree height. Modifications of Hohenadl's procedure were applied to two sets of data for western hemlock (Tsuga heterophylla (Raf.) Sarg.) from the Pacific Northwest. The procedure was used to define...

  4. 33 CFR 67.35-1 - Procedure.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Procedure. 67.35-1 Section 67.35-1 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION AIDS TO NAVIGATION ON ARTIFICIAL ISLANDS AND FIXED STRUCTURES Applications § 67.35-1 Procedure. (a) An...

  5. 33 CFR 67.35-1 - Procedure.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Procedure. 67.35-1 Section 67.35-1 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY AIDS TO NAVIGATION AIDS TO NAVIGATION ON ARTIFICIAL ISLANDS AND FIXED STRUCTURES Applications § 67.35-1 Procedure. (a) An...

  6. Immunofluorescent staining of rabies virus antigen in formalin-fixed tissue after treatment with trypsin

    PubMed Central

    Umoh, J. U.; Blenden, D. C.

    1981-01-01

    Formalin-fixed central nervous system tissue from clinically rabid animals was treated with 0.25% trypsin and tested for the presence of rabies virus antigen by direct immunofluorescent (IF) staining. The results were comparable with those obtained from direct IF staining of acetone-fixed standard smears or fresh frozen-cut sections. Experiments were conducted using coded brain specimens (classified as IF-negative, weakly positive, or strongly positive) and showed a specificity of 100% for sections and 92% for smears; the latter figure was subsequently improved by modifying the preparation technique. The specificity of the technique was checked by standard virus neutralization of the conjugate, and by known antibody neutralization of the virus antigen in the specimens. The optimal duration for the trypsin digestion was found to be a minimum of 60 minutes at 37 °C or 120 minutes at 4 °C. The tissues could be held in buffered formalin for between 3 days and 7 weeks with no apparent difference in the results. Satisfactory concentrations of formalin were 0.125% or 0.25%. Trypsin was found to have no effect on non-formalinized tissues, with the exception that softening occurred making tissues harder to cut and process. The results suggest that trypsinization of formalin-fixed tissue is a valid procedure for the preparation of tissues for IF examination, which would be useful in cases where the current standard techniques cannot be used. However, further evaluation of the method is still required. ImagesFig. 3Fig. 1Fig. 2 PMID:6172212

  7. Combining Heterogeneous Correlation Matrices: Simulation Analysis of Fixed-Effects Methods

    ERIC Educational Resources Information Center

    Hafdahl, Adam R.

    2008-01-01

    Monte Carlo studies of several fixed-effects methods for combining and comparing correlation matrices have shown that two refinements improve estimation and inference substantially. With rare exception, however, these simulations have involved homogeneous data analyzed using conditional meta-analytic procedures. The present study builds on…

  8. When Is Rapid On-Site Evaluation Cost-Effective for Fine-Needle Aspiration Biopsy?

    PubMed Central

    Schmidt, Robert L.; Walker, Brandon S.; Cohen, Michael B.

    2015-01-01

    Background Rapid on-site evaluation (ROSE) can improve adequacy rates of fine-needle aspiration biopsy (FNAB) but increases operational costs. The performance of ROSE relative to fixed sampling depends on many factors. It is not clear when ROSE is less costly than sampling with a fixed number of needle passes. The objective of this study was to determine the conditions under which ROSE is less costly than fixed sampling. Methods Cost comparison of sampling with and without ROSE using mathematical modeling. Models were based on a societal perspective and used a mechanistic, micro-costing approach. Sampling policies (ROSE, fixed) were compared using the difference in total expected costs per case. Scenarios were based on procedure complexity (palpation-guided or image-guided), adequacy rates (low, high) and sampling protocols (stopping criteria for ROSE and fixed sampling). One-way, probabilistic, and scenario-based sensitivity analysis was performed to determine which variables had the greatest influence on the cost difference. Results ROSE is favored relative to fixed sampling under the following conditions: (1) the cytologist is accurate, (2) the total variable cost ($/hr) is low, (3) fixed costs ($/procedure) are high, (4) the setup time is long, (5) the time between needle passes for ROSE is low, (6) when the per-pass adequacy rate is low, and (7) ROSE stops after observing one adequate sample. The model is most sensitive to variation in the fixed cost, the per-pass adequacy rate, and the time per needle pass with ROSE. Conclusions Mathematical modeling can be used to predict the difference in cost between sampling with and without ROSE. PMID:26317785

  9. Exposure calculation code module for reactor core analysis: BURNER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vondy, D.R.; Cunningham, G.W.

    1979-02-01

    The code module BURNER for nuclear reactor exposure calculations is presented. The computer requirements are shown, as are the reference data and interface data file requirements, and the programmed equations and procedure of calculation are described. The operating history of a reactor is followed over the period between solutions of the space, energy neutronics problem. The end-of-period nuclide concentrations are determined given the necessary information. A steady state, continuous fueling model is treated in addition to the usual fixed fuel model. The control options provide flexibility to select among an unusually wide variety of programmed procedures. The code also providesmore » user option to make a number of auxiliary calculations and print such information as the local gamma source, cumulative exposure, and a fine scale power density distribution in a selected zone. The code is used locally in a system for computation which contains the VENTURE diffusion theory neutronics code and other modules.« less

  10. The effects of age-in-block on RNA-seq analysis of archival formalin-fixed paraffin-embedded (FFPE) samples

    EPA Science Inventory

    Archival samples represent a vast resource for identification of chemical and pharmaceutical targets. Previous use of formalin-fixed paraffin-embedded (FFPE) samples has been limited due to changes in RNA introduced by fixation and embedding procedures. Recent advances in RNA-seq...

  11. 48 CFR 31.204 - Application of principles and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-price subcontract with economic price adjustment provisions. (c) Costs incurred as payments under firm-fixed-price subcontracts or fixed-price subcontracts with economic price adjustment provisions or... captures the essential nature of, the cost at issue. [48 FR 42301, Sept. 19, 1983, as amended at 53 FR...

  12. An Introduction to the Federal Information Exchange System.

    ERIC Educational Resources Information Center

    De Santi, Vincent; Scheele, D. Sam

    This publication offers a basic introduction to the Federal Information Exchange System (FIXS), a set of procedures for periodically collecting, processing, and publishing data on federal and state expenditures for each program listed in the "Catalog of Federal Assistance Programs." FIXS is designed for use in conjunction with the…

  13. Sampling Using a Fixed Number of Trees Per Plot

    Treesearch

    Hans T. Schreuder

    2004-01-01

    The fixed number of trees sample design proposed by Jonsson and others (1992) may be dangerous in applications if a probabilistic framework of sampling is desired. The procedure can be seriously biased. Examples are given here.Publication Web Site:http://www.fs.fed.us/rm/pubs/rmrs_rn017.html

  14. 40 CFR 60.745 - Test methods and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... determination of the efficiency of a fixed-bed carbon adsorption system with a common exhaust stack for all the... separate runs, each coinciding with one or more complete system rotations through the adsorption cycles of... efficiency of a fixed-bed carbon adsorption system with individual exhaust stacks for each adsorber vessel...

  15. 40 CFR 60.745 - Test methods and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... determination of the efficiency of a fixed-bed carbon adsorption system with a common exhaust stack for all the... separate runs, each coinciding with one or more complete system rotations through the adsorption cycles of... efficiency of a fixed-bed carbon adsorption system with individual exhaust stacks for each adsorber vessel...

  16. Rivaling paradigms in psychiatric neurosurgery: adjustability versus quick fix versus minimal-invasiveness.

    PubMed

    Müller, Sabine; Riedmüller, Rita; van Oosterhout, Ansel

    2015-01-01

    In the wake of deep brain stimulation (DBS) development, ablative neurosurgical procedures are seeing a comeback, although they had been discredited and nearly completely abandoned in the 1970s because of their unethical practice. Modern stereotactic ablative procedures as thermal or radiofrequency ablation, and particularly radiosurgery (e.g., Gamma Knife) are much safer than the historical procedures, so that a re-evaluation of this technique is required. The different approaches of modern psychiatric neurosurgery refer to different paradigms: microsurgical ablative procedures is based on the paradigm 'quick fix,' radiosurgery on the paradigm 'minimal-invasiveness,' and DBS on the paradigm 'adjustability.' From a mere medical perspective, none of the procedures is absolutely superior; rather, they have different profiles of advantages and disadvantages. Therefore, individual factors are crucial in decision-making, particularly the patients' social situation, individual preferences, and individual attitudes. The different approaches are not only rivals, but also enriching mutually. DBS is preferable for exploring new targets, which may become candidates for ablative microsurgery or radiosurgery.

  17. Kinetics of suicide substrates. Practical procedures for determining parameters.

    PubMed Central

    Waley, S G

    1985-01-01

    Many clinically important or mechanistically interesting inhibitors react with enzymes by a branched pathway in which inactivation of the enzyme and formation of product are competing reactions. The steady-state kinetics for this pathway [Waley (1980) Biochem. J. 185, 771-773] gave equations for progress curves that were cumbersome. A convenient linear plot is now described. The time (t1/2) for 50% inactivation of the enzyme (this is also the time for 50% formation of product), or for 50% loss of substrate, is measured in a series of experiments in which the concentration of inhibitor, [I]0, is varied; in these experiments the ratio of the concentration of enzyme to the concentration of inhibitor is kept fixed. Then a plot of [I]0 X t1/2 against [I]0 is linear, and the kinetic parameters can be found from the slope and intercept. Furthermore, simplifications of the equations for progress curves are described that are valid when the concentration of inhibitors is high, or is low, or when the extent of reaction is low. The use of simulated data has shown that the recommended methods are not unduly sensitive to experimental error. PMID:4004802

  18. Thermodynamic Pressure/Temperature Transducer Health Check

    NASA Technical Reports Server (NTRS)

    Immer, Christopher D. (Inventor); Eckhoff, Anthony (Inventor); Medelius, Pedro J. (Inventor); Deyoe, Richard T. (Inventor); Starr, Stanley O. (Inventor)

    2004-01-01

    A device and procedure for checking the health of a pressure transducer in situ is provided. The procedure includes measuring a fixed change in pressure above ambient pressure and a fixed change in pressure below ambient pressure. This is done by first sealing an enclosed volume around the transducer with a valve. A piston inside the sealed volume is increasing the pressure. A fixed pressure below ambient pressure is obtained by opening the valve, driving the piston The output of the pressure transducer is recorded for both the overpressuring and the underpressuring. By comparing this data with data taken during a preoperative calibration, the health of the transducer is determined from the linearity, the hysteresis, and the repeatability of its output. The further addition of a thermometer allows constant offset error in the transducer output to be determined.

  19. Structural and thermal properties of inorganic-organic montmorillonite: Implications for their potential environmental applications.

    PubMed

    Rathnayake, Suramya I; Xi, Yunfei; Frost, Ray L; Ayoko, Godwin A

    2015-12-01

    Inorganic-organic clays (IOCs), clays intercalated with both organic cations such as cationic surfactants and inorganic cations such as metal hydroxy polycations have the properties of both organic and pillared clays, and thereby the ability to remove both inorganic and organic contaminants from water simultaneously. In this study, IOCs were synthesised using three different methods with different surfactant concentrations. Octadecyltrimethylammonium bromide (ODTMA) and hydroxy aluminium ([Al13O4(OH)24(H2O)12](7+) or Al13) are used as the organic and inorganic modifiers (intercalation agents). According to the results, the interlayer distance, the surfactant loading amount and the Al/Si ratio of IOCs strictly depend on the intercalation method and the intercalation agent ratio. Interlayers of IOCs synthesised by intercalating ODTMA before Al13 and IOCs synthesised by simultaneous intercalation of ODTMA and Al13 were increased with increasing the ODTMA concentration used in the synthesis procedure and comparatively high loading amounts could be observed in them. In contrast, Al/Si decreased with increasing ODTMA concentration in these two types of IOCs. The results suggest that Al-pillars can be fixed within the interlayers by calcination and any increment in the amount of ODTMA used in the synthesis procedure did not affect the interlayer distance of the IOCs. Overall the study provides valuable insights into the structure and properties of the IOCs and their potential environmental applications. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Device-Task Fidelity and Transfer of Training: Aircraft Cockpit Procedures Training.

    ERIC Educational Resources Information Center

    Prophet, Wallace W.; Boyd, H. Alton

    An evaluation was made of the training effectiveness of two cockpit procedures training devices, differing greatly in physical fidelity and cost, for use on the ground for a twin-engine, turboprop, fixed-wing aircraft. One group of students received training in cockpit procedures in a relatively expensive, sophisticated, computerized trainer,…

  1. Surface-water quality at fixed sites in the Western Lake Michigan Drainages, Wisconsin and Michigan, and the effects of natural and human factors, 1993-95

    USGS Publications Warehouse

    Richards, K.D.; Sullivan, D.J.; Stewart, J.S.

    1998-01-01

    Streamwater samples were collected from April 1993 through July 1995 at 11 fixed sites in the Western Lake Michigan Drainages Study Unit of the U.S. Geological Survey's National Water-Quality Assessment Program. Water samples were collected monthly at all Fixed Sites, and an additional two to four samples were collected each year during periods of high flow. Streamflow was monitored continuously at the Fixed Sites for the duration of the study period. This report describes field techniques used to collect the water samples, and the analytical methods used for laboratory analyses, statistical analyses of the data, and an attempt to determine the effect of natural and anthropogenic factors on concentrations of nutrients and selected major ions and suspended solids. Locations of eight of the Fixed Sites were selected to represent areas with unique combinations of land use/land cover, surficial deposits, and bedrock geology and are referred to as 'indicator sites.' The remaining three sites were located near the mouths of major rivers and are referred to as 'integrator sites.' The integrator sites represent a large part of the total flow from the Study Unit to Green Bay and western Lake Michigan, and drain various combinations of land use, bedrock, and surficial deposits. These data indicate that land use and surficial deposits may be the primary factors affecting nitrate and total phosphorus concentrations in this Study Unit. Median concentrations of nitrate at the forested sites were less than the National Median Concentration (NMC), and those at urban fixed sites were similar to the NMC. Median nitrate concentrations at the Tomorrow River, North Branch Milwaukee River, and Duck Creek agricultural indicator sites were twice the NMC, but median concentrations at the remaining agricultural indicator sites were similar to the NMC. Nitrate concentrations at one agricultural indicator site exceeded the U. S. Environmental Protection Agency (USEPA) maximum contaminant level in three run-off samples in the growing seasons of 1994 and 1995. Median concentrations of total phosphorus at the forested indicator sites were below the NMC. Tomorrow River was the only agricultural indicator site where the median total-phosphorus concentration was less than the NMC; median concentrations at the remaining agricultural Fixed Sites were similar to the NMC and exceeded 0.1 mg/L, the USEPA suggested total-phosphorus concentration in flowing water. The USEPA recommends that total-phosphorus concentration not exceed this limit to discourage excessive aquatic plant growth in flowing waters. Median total-phosphorus concentration at the urban indicator site was less than the urban NMC. Median concentrations for both nitrate and total phosphorus at the mouth of the Fox River and the Milwaukee River integrator sites were similar to the NMC for the dominant land use, agriculture, within their basins, and were lower than that at the Menominee River integrator site with a dominant forest land use. During this study, potassium concentrations were generally highest in areas of clay-dominated surficial deposits, silica was generally highest in areas of sandy surficial deposits, iron generally highest in areas of igneous/metamorphic bedrock, and calcium generally highest in areas of carbonate bedrock. The highest median fluoride concentration occurred at an urban site that receives treated water.

  2. 18 CFR 11.14 - Procedures for establishing charges without an energy gains investigation.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... hydrology or project development, that affect headwater benefits. (2) Any procedures that apply to § 11.17(b)(5) of this subpart will apply to any prospectively fixed charges that are continued under this...

  3. 18 CFR 11.14 - Procedures for establishing charges without an energy gains investigation.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... hydrology or project development, that affect headwater benefits. (2) Any procedures that apply to § 11.17(b)(5) of this subpart will apply to any prospectively fixed charges that are continued under this...

  4. 47 CFR 5.61 - Procedure for obtaining a special temporary authorization.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Office of Engineering and Technology Web site https://gullfoss2.fcc.gov/prod/oet/cf/els/index.cfm effective January 1, 2004 and shall contain the following information: (1) Name, address, phone number (also... proposed operation. (5) Class(es) of station (fixed, mobile, fixed and mobile) and call sign of station (if...

  5. Pigeons' Choices between Fixed-Interval and Random-Interval Schedules: Utility of Variability?

    ERIC Educational Resources Information Center

    Andrzejewski, Matthew E.; Cardinal, Claudia D.; Field, Douglas P.; Flannery, Barbara A.; Johnson, Michael; Bailey, Kathleen; Hineline, Philip N.

    2005-01-01

    Pigeons' choosing between fixed-interval and random-interval schedules of reinforcement was investigated in three experiments using a discrete-trial procedure. In all three experiments, the random-interval schedule was generated by sampling a probability distribution at an interval (and in multiples of the interval) equal to that of the…

  6. Two-Phase Item Selection Procedure for Flexible Content Balancing in CAT

    ERIC Educational Resources Information Center

    Cheng, Ying; Chang, Hua-Hua; Yi, Qing

    2007-01-01

    Content balancing is an important issue in the design and implementation of computerized adaptive testing (CAT). Content-balancing techniques that have been applied in fixed content balancing, where the number of items from each content area is fixed, include constrained CAT (CCAT), the modified multinomial model (MMM), modified constrained CAT…

  7. 18 CFR 401.96 - Factors to be applied in fixing penalty amount.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 2 2011-04-01 2011-04-01 false Factors to be applied in fixing penalty amount. 401.96 Section 401.96 Conservation of Power and Water Resources DELAWARE RIVER BASIN COMMISSION ADMINISTRATIVE MANUAL RULES OF PRACTICE AND PROCEDURE Penalties and Settlements...

  8. Application of Monte Carlo Method for Evaluation of Uncertainties of ITS-90 by Standard Platinum Resistance Thermometer

    NASA Astrophysics Data System (ADS)

    Palenčár, Rudolf; Sopkuliak, Peter; Palenčár, Jakub; Ďuriš, Stanislav; Suroviak, Emil; Halaj, Martin

    2017-06-01

    Evaluation of uncertainties of the temperature measurement by standard platinum resistance thermometer calibrated at the defining fixed points according to ITS-90 is a problem that can be solved in different ways. The paper presents a procedure based on the propagation of distributions using the Monte Carlo method. The procedure employs generation of pseudo-random numbers for the input variables of resistances at the defining fixed points, supposing the multivariate Gaussian distribution for input quantities. This allows taking into account the correlations among resistances at the defining fixed points. Assumption of Gaussian probability density function is acceptable, with respect to the several sources of uncertainties of resistances. In the case of uncorrelated resistances at the defining fixed points, the method is applicable to any probability density function. Validation of the law of propagation of uncertainty using the Monte Carlo method is presented on the example of specific data for 25 Ω standard platinum resistance thermometer in the temperature range from 0 to 660 °C. Using this example, we demonstrate suitability of the method by validation of its results.

  9. Dynamic transition between fixed- and mobile-bed: mathematical and numerical aspects

    NASA Astrophysics Data System (ADS)

    Zugliani, Daniel; Pasqualini, Matteo; Rosatti, Giorgio

    2017-04-01

    Free-surface flows with high sediment transport (as debris flow or hyper-concentrated flow) are composed by a mixture of fluid and solid phase, usually water and sediment. When these flows propagate over loose beds, particles constituting the mixture of water and sediments strongly interact with the ones forming the bed, leading to erosion or deposition. However, there are lots of other situations when the mixture flows over rigid bedrocks or over artificially paved transects, so there is no mass exchange between bed and mixture. The two situations are usually referred to as, respectively, mobile- and fixed-bed conditions. From a mathematical point of view, the systems of Partial Differential Equations (PDEs) that describe these flows derive from mass and momentum balance of both phases, but, the two resulting PDEs systems are different. The main difference concerns the concentration: in the mobile-bed condition, the concentration is linked to the local flow conditions by means of a suitable rheological relation, while in the fixed-bed case, the concentration is an unknown of the problem. It is quite common that a free surface flow with high sediment transport, in its path, encounters both conditions. In the recent work of Rosatti & Zugliani 2015, the mathematical and numerical description of the transition between fixed- and mobile-bed was successfully resolved, for the case of low sediment transport phenomena, by the introduction of a suitable erodibility variable and satisfactory results were obtained. The main disadvantage of the approach is related to the erodibility variable, that changes in space, based on bed characteristics, but remains constant in time. However, the nature of the bed can change dynamically as result of deposition over fixed bed or high erosion over mobile bed. With this work, we extend the applicability of the mentioned approach to the more complex PDEs describing the hyper-concentrated flow. Moreover, we introduce a strategy that allows a dynamic time variation of the erodibility variable. The issue of the dynamic transition between fixed- and mobile-bed condition is tackled, from a numerical point of view, using a particular predictor corrector technique that compare the transported concentration related with the fixed bed and the equilibrium concentration, deriving from a closure relation, associated to the mobile bed condition. Through a comparison between exact solution, built using the generalized Rankine - Hugoniot condition, and the numeric results, we highlight capabilities and limits of this enhanced technique. Bibliography: G. Rosatti and D. Zugliani, 2015. "Modelling the transition between fixed and mobile bed conditions in two-phase free-surface flows: The Composite Riemann Problem and its numerical solution". Journal of Computational Physics, 285:226-250

  10. Mouse hepatitis virus immunofluorescence in formalin- or Bouin's-fixed tissues using trypsin digestion.

    PubMed

    Brownstein, D G; Barthold, S W

    1982-02-01

    Mouse hepatitis viral antigens were demonstrated by immunofluorescence in formalin- and Bouin's-fixed tissues processed routinely for histopathology followed by partial digestion with trypsin. Staining was superior in tissues fixed in formalin and was not diminished in tissue sections from paraffin blocks stored at room temperature as long as 2 years. The relative ease of this procedure and the commercial availability of reagents makes this a useful technique for the definitive diagnosis of mouse hepatitis virus infection.

  11. 47 CFR 101.75 - Involuntary relocation procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... adjustments, determine comparability, and ensure a seamless handoff. (d) Twelve-month trial period. If, within... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses License Transfers, Modifications, Conditions and Forfeitures § 101.75 Involuntary relocation procedures. (a) If no agreement is reached during the...

  12. 47 CFR 101.75 - Involuntary relocation procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... adjustments, determine comparability, and ensure a seamless handoff. (d) Twelve-month trial period. If, within... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses License Transfers, Modifications, Conditions and Forfeitures § 101.75 Involuntary relocation procedures. (a) If no agreement is reached during the...

  13. 47 CFR 101.75 - Involuntary relocation procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... adjustments, determine comparability, and ensure a seamless handoff. (d) Twelve-month trial period. If, within... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses License Transfers, Modifications, Conditions and Forfeitures § 101.75 Involuntary relocation procedures. (a) If no agreement is reached during the...

  14. 47 CFR 101.75 - Involuntary relocation procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... adjustments, determine comparability, and ensure a seamless handoff. (d) Twelve-month trial period. If, within... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses License Transfers, Modifications, Conditions and Forfeitures § 101.75 Involuntary relocation procedures. (a) If no agreement is reached during the...

  15. Sampling design and procedures for fixed surface-water sites in the Georgia-Florida coastal plain study unit, 1993

    USGS Publications Warehouse

    Hatzell, H.H.; Oaksford, E.T.; Asbury, C.E.

    1995-01-01

    The implementation of design guidelines for the National Water-Quality Assessment (NAWQA) Program has resulted in the development of new sampling procedures and the modification of existing procedures commonly used in the Water Resources Division of the U.S. Geological Survey. The Georgia-Florida Coastal Plain (GAFL) study unit began the intensive data collection phase of the program in October 1992. This report documents the implementation of the NAWQA guidelines by describing the sampling design and procedures for collecting surface-water samples in the GAFL study unit in 1993. This documentation is provided for agencies that use water-quality data and for future study units that will be entering the intensive phase of data collection. The sampling design is intended to account for large- and small-scale spatial variations, and temporal variations in water quality for the study area. Nine fixed sites were selected in drainage basins of different sizes and different land-use characteristics located in different land-resource provinces. Each of the nine fixed sites was sampled regularly for a combination of six constituent groups composed of physical and chemical constituents: field measurements, major ions and metals, nutrients, organic carbon, pesticides, and suspended sediments. Some sites were also sampled during high-flow conditions and storm events. Discussion of the sampling procedure is divided into three phases: sample collection, sample splitting, and sample processing. A cone splitter was used to split water samples for the analysis of the sampling constituent groups except organic carbon from approximately nine liters of stream water collected at four fixed sites that were sampled intensively. An example of the sample splitting schemes designed to provide the sample volumes required for each sample constituent group is described in detail. Information about onsite sample processing has been organized into a flowchart that describes a pathway for each of the constituent groups.

  16. Delay Discounting in Lewis and Fischer 344 Rats: Steady-State and Rapid-Determination Adjusting-Amount Procedures

    ERIC Educational Resources Information Center

    Stein, Jeffrey S.; Pinkston, Jonathan W.; Brewer, Adam T.; Francisco, Monica T.; Madden, Gregory J.

    2012-01-01

    Lewis rats have been shown to make more impulsive choices than Fischer 344 rats in discrete trial choice procedures that arrange fixed (i.e., nontitrating) reinforcement parameters. However, nontitrating procedures yield only gross estimates of preference, as choice measures in animal subjects are rarely graded at the level of the individual…

  17. Examination of a Method to Determine the Reference Region for Calculating the Specific Binding Ratio in Dopamine Transporter Imaging.

    PubMed

    Watanabe, Ayumi; Inoue, Yusuke; Asano, Yuji; Kikuchi, Kei; Miyatake, Hiroki; Tokushige, Takanobu

    2017-01-01

    The specific binding ratio (SBR) was first reported by Tossici-Bolt et al. for quantitative indicators for dopamine transporter (DAT) imaging. It is defined as the ratio of the specific binding concentration of the striatum to the non-specific binding concentration of the whole brain other than the striatum. The non-specific binding concentration is calculated based on the region of interest (ROI), which is set 20 mm inside the outer contour, defined by a threshold technique. Tossici-Bolt et al. used a 50% threshold, but sometimes we couldn't define the ROI of non-specific binding concentration (reference region) and calculate SBR appropriately with a 50% threshold. Therefore, we sought a new method for determining the reference region when calculating SBR. We used data from 20 patients who had undergone DAT imaging in our hospital, to calculate the non-specific binding concentration by the following methods, the threshold to define a reference region was fixed at some specific values (the fixing method) and reference region was visually optimized by an examiner at every examination (the visual optimization method). First, we assessed the reference region of each method visually, and afterward, we quantitatively compared SBR calculated based on each method. In the visual assessment, the scores of the fixing method at 30% and visual optimization method were higher than the scores of the fixing method at other values, with or without scatter correction. In the quantitative assessment, the SBR obtained by visual optimization of the reference region, based on consensus of three radiological technologists, was used as a baseline (the standard method). The values of SBR showed good agreement between the standard method and both the fixing method at 30% and the visual optimization method, with or without scatter correction. Therefore, the fixing method at 30% and the visual optimization method were equally suitable for determining the reference region.

  18. Probabilistic Motor Sequence Yields Greater Offline and Less Online Learning than Fixed Sequence

    PubMed Central

    Du, Yue; Prashad, Shikha; Schoenbrun, Ilana; Clark, Jane E.

    2016-01-01

    It is well acknowledged that motor sequences can be learned quickly through online learning. Subsequently, the initial acquisition of a motor sequence is boosted or consolidated by offline learning. However, little is known whether offline learning can drive the fast learning of motor sequences (i.e., initial sequence learning in the first training session). To examine offline learning in the fast learning stage, we asked four groups of young adults to perform the serial reaction time (SRT) task with either a fixed or probabilistic sequence and with or without preliminary knowledge (PK) of the presence of a sequence. The sequence and PK were manipulated to emphasize either procedural (probabilistic sequence; no preliminary knowledge (NPK)) or declarative (fixed sequence; with PK) memory that were found to either facilitate or inhibit offline learning. In the SRT task, there were six learning blocks with a 2 min break between each consecutive block. Throughout the session, stimuli followed the same fixed or probabilistic pattern except in Block 5, in which stimuli appeared in a random order. We found that PK facilitated the learning of a fixed sequence, but not a probabilistic sequence. In addition to overall learning measured by the mean reaction time (RT), we examined the progressive changes in RT within and between blocks (i.e., online and offline learning, respectively). It was found that the two groups who performed the fixed sequence, regardless of PK, showed greater online learning than the other two groups who performed the probabilistic sequence. The groups who performed the probabilistic sequence, regardless of PK, did not display online learning, as indicated by a decline in performance within the learning blocks. However, they did demonstrate remarkably greater offline improvement in RT, which suggests that they are learning the probabilistic sequence offline. These results suggest that in the SRT task, the fast acquisition of a motor sequence is driven by concurrent online and offline learning. In addition, as the acquisition of a probabilistic sequence requires greater procedural memory compared to the acquisition of a fixed sequence, our results suggest that offline learning is more likely to take place in a procedural sequence learning task. PMID:26973502

  19. Probabilistic Motor Sequence Yields Greater Offline and Less Online Learning than Fixed Sequence.

    PubMed

    Du, Yue; Prashad, Shikha; Schoenbrun, Ilana; Clark, Jane E

    2016-01-01

    It is well acknowledged that motor sequences can be learned quickly through online learning. Subsequently, the initial acquisition of a motor sequence is boosted or consolidated by offline learning. However, little is known whether offline learning can drive the fast learning of motor sequences (i.e., initial sequence learning in the first training session). To examine offline learning in the fast learning stage, we asked four groups of young adults to perform the serial reaction time (SRT) task with either a fixed or probabilistic sequence and with or without preliminary knowledge (PK) of the presence of a sequence. The sequence and PK were manipulated to emphasize either procedural (probabilistic sequence; no preliminary knowledge (NPK)) or declarative (fixed sequence; with PK) memory that were found to either facilitate or inhibit offline learning. In the SRT task, there were six learning blocks with a 2 min break between each consecutive block. Throughout the session, stimuli followed the same fixed or probabilistic pattern except in Block 5, in which stimuli appeared in a random order. We found that PK facilitated the learning of a fixed sequence, but not a probabilistic sequence. In addition to overall learning measured by the mean reaction time (RT), we examined the progressive changes in RT within and between blocks (i.e., online and offline learning, respectively). It was found that the two groups who performed the fixed sequence, regardless of PK, showed greater online learning than the other two groups who performed the probabilistic sequence. The groups who performed the probabilistic sequence, regardless of PK, did not display online learning, as indicated by a decline in performance within the learning blocks. However, they did demonstrate remarkably greater offline improvement in RT, which suggests that they are learning the probabilistic sequence offline. These results suggest that in the SRT task, the fast acquisition of a motor sequence is driven by concurrent online and offline learning. In addition, as the acquisition of a probabilistic sequence requires greater procedural memory compared to the acquisition of a fixed sequence, our results suggest that offline learning is more likely to take place in a procedural sequence learning task.

  20. Ultraviolet spectrophotometric determination of tantalum with pyrogallol

    USGS Publications Warehouse

    Dinnin, J.I.

    1953-01-01

    In a search for a more rapid method for the determination of tantalum in rocks and minerals, an intensive study was made of the tantalum-pyrogallol reaction recommended by Platanov and Krivoshlikov, and a better modified spectrophotometric procedure is given. The improved method consists in measuring the absorbancy of the tantalum-pyrogallol complex at 325 m?? in 4N hydrochloric acid and a fixed concentration (0.0175M) of ammonium oxalate. Beer's law is followed for the concentration range up to 40 ?? per ml. Sensitivity in terms of molar absorbancy index is 4775. Most interferences are additive in character and readily correctable. Separations or major corrections are required in the presence of significant amounts of molybdenum, tungsten, antimony, and uranium. The method has been successfully applied to three ores previously analyzed by gravimetric techniques. The method affords greater speed, sensitivity, and reproducibility in the determination of tantalum in rocks and minerals. A more reliable technique for preparing standard solutions of tantalum has been developed.

  1. The formulaic schema in the minds of two generations of native speakers

    PubMed Central

    Van Lancker Sidtis, Diana; Cameron, Krista; Bridges, Kelly; Sidtis, John J.

    2015-01-01

    Schemata are expressions that are fixed except for slots available for novel words (I’m not a ______ person). Our goals were to quantify speakers’ knowledge, examine semantic flexibility in open slots, and compare performance data in two generations of speakers using cloze procedures in formulaic expressions, schemata open slots, fixed portions of schemata, and novel sentences. Fewer unique words appeared for the schemata-fixed and formulaic exemplars, reflecting speakers’ knowledge of these utterances; the most semantic categories appeared for schemata-open responses. Age groups did not differ. Schemata exemplify creative interplay between novel lexical retrieval and fixed formulaic expression. PMID:26392923

  2. Sensitive Procedures for Determining the Permeation Resistance of Chlorinated Polyethylene Against Liquid Propellants

    NASA Technical Reports Server (NTRS)

    Waller, Jess M.; Williams, James H.; Fries, Joseph (Technical Monitor)

    1999-01-01

    The permeation resistance of chlorinated polyethylene (CPE) used in totally encapsulating chemical protective suits against the aerospace fuels hydrazine, monomethylhydrazine, and uns-dimethylhydrazine was determined by measuring the breakthrough time (BT) and time-averaged vapor transmission rate (VTR) using procedures consistent with ASTM F 739 and ASTM F 1383. Two exposure scenarios were simulated: a 2 hour (h) fuel vapor exposure, and a liquid fuel "splash" followed by a 2 h vapor exposure. To simulate internal suit pressure during operation, a positive differential pressure of 0.3 in. water (75 Pa) on the collection side of the permeation apparatus was used. Using the available data, a model was developed to estimate propellant concentrations inside an air-line fed, totally encapsulating chemical protective suit. Concentrations were calculated under simulated conditions of fixed vapor transmission rate, variable breathing air flow rate, and variable splash exposure area. Calculations showed that the maximum allowable permeation rates of hydrazine fuels through CPE were of the order of 0.05 to 0.08 ng/sq cm min for encapsulating suits with low breathing air flow rates (of the order of 5 scfm or 140 L min-1). Above these permeation rates, the 10 parts-per-billion (ppb) threshold limit value time-weighted average could be exceeded. To evaluate suit performance at 10 ppb threshold-limiting value/time-weighted average level concentrations, use of a sensitive analytical method such as cation exchange high performance liquid chromatography with amperometric detection was found to be essential. The analytical detection limit determines the lowest measurable VTR, which in turn governed the lowest per meant concentration that could be calculated inside the totally encapsulating chemical protective suit.

  3. Evaluation of Shiryaev-Roberts procedure for on-line environmental radiation monitoring.

    PubMed

    Watson, Mara M; Seliman, Ayman F; Bliznyuk, Valery N; DeVol, Timothy A

    2018-04-30

    Water can become contaminated as a result of a leak from a nuclear facility, such as a waste facility, or from clandestine nuclear activity. Low-level on-line radiation monitoring is needed to detect these events in real time. A Bayesian control chart method, Shiryaev-Roberts (SR) procedure, was compared with classical methods, 3-σ and cumulative sum (CUSUM), for quantifying an accumulating signal from an extractive scintillating resin flow-cell detection system. Solutions containing 0.10-5.0 Bq/L of 99 Tc, as T99cO 4 - were pumped through a flow cell packed with extractive scintillating resin used in conjunction with a Beta-RAM Model 5 HPLC detector. While T99cO 4 - accumulated on the resin, time series data were collected. Control chart methods were applied to the data using statistical algorithms developed in MATLAB. SR charts were constructed using Poisson (Poisson SR) and Gaussian (Gaussian SR) probability distributions of count data to estimate the likelihood ratio. Poisson and Gaussian SR charts required less volume of radioactive solution at a fixed concentration to exceed the control limit in most cases than 3-σ and CUSUM control charts, particularly solutions with lower activity. SR is thus the ideal control chart for low-level on-line radiation monitoring. Once the control limit was exceeded, activity concentrations were estimated from the SR control chart using the control chart slope on a semi-logarithmic plot. A linear regression fit was applied to averaged slope data for five activity concentration groupings for Poisson and Gaussian SR control charts. A correlation coefficient (R 2 ) of 0.77 for Poisson SR and 0.90 for Gaussian SR suggest this method will adequately estimate activity concentration for an unknown solution. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. An operation manual for a time-series, storm-activated suspended sediment sampler deployed in the coastal ocean: function, maintenance, and testing procedures

    USGS Publications Warehouse

    Rendigs, Richard R.; Bothner, Michael H.

    2004-01-01

    This manual describes the operation and testing procedures for two models of a multi-port suspended sediment sampler that are moored in the coastal ocean and that collect samples on a programmable time schedule that can be interrupted to collect during a storm. The ability to sense and collect samples before, during, and after the height of a storm is a unique feature of these instruments because it provides samples during conditions when it is difficult or impossible to sample from a surface ship. The sensors used to trigger storm sampling are a transmissometer or a pressure sensor. The purpose of such samples is to assess composition and concentration of sediment resuspended from the seafloor during storms and subsequently transported within the coastal system. Both light transmission and the standard deviation of pressure from surface waves correlate with the passage of major storms. The instruments successfully identified the onset of storms and collected samples before, during, and after the storm maximum as programmed. The accuracy of determining suspended matter concentrations collected by the sediment sampler has not been fully evaluated. Preliminary laboratory tests using a suspension of muddy sediment collected in a near-bottom sediment trap yielded excellent results. However in laboratory tests with different sediment types, the suspended matter concentrations determined with these samplers became less accurate with increasing average grain size. Future calibration work is necessary and should be conducted in a facility that ideally has a water depth of at least 30 feet to prevent cavitation of the pump that draws sea water through the filters. The test facility should also have the capability for adding suspended matter of known composition and concentration to a fixed volume of seawater that is well mixed.

  5. 47 CFR 101.819 - Stations affected by coordination contour procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Stations affected by coordination contour procedures. 101.819 Section 101.819 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Local Television Transmission Service § 101.819...

  6. 47 CFR 101.819 - Stations affected by coordination contour procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Stations affected by coordination contour procedures. 101.819 Section 101.819 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Local Television Transmission Service § 101.819...

  7. 47 CFR 101.819 - Stations affected by coordination contour procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Stations affected by coordination contour procedures. 101.819 Section 101.819 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Local Television Transmission Service § 101.819...

  8. 47 CFR 101.819 - Stations affected by coordination contour procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Stations affected by coordination contour procedures. 101.819 Section 101.819 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Local Television Transmission Service § 101.819...

  9. 47 CFR 101.819 - Stations affected by coordination contour procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Stations affected by coordination contour procedures. 101.819 Section 101.819 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Local Television Transmission Service § 101.819...

  10. A System Approach to Navy Medical Education and Training. Appendix 44. Competency Curriculum for Dental Assistant.

    DTIC Science & Technology

    1974-08-31

    Prosthodontic Appliances - Partial Dentures .... ....... ....... .... 59 2. Removable Prosthodontic Appliances - Full Dentures ..... ........... . 60 3...PROCEDURES I This unit includes the following Modules: Number Title Page 1 Removable Prosthodontic Appliances - Partial Dentures 59. ......... ...... 2...Removable Prostbodontic Appliances - Full Dentures ..... ...... a .. .. .. . 60 3 Fixed Prosthodontic Appliances - Fixed Bridge. . 61 4 Mouthquard

  11. Designing a fixed-blade gang ripsaw arbor with a pencil

    Treesearch

    Charles J. Gatchell; Charles J. Gatchell

    1996-01-01

    This paper presents a step-by-step procedure for designing the "best" sequence of saw spacings for a fixed-blade gang ripsaw arbor. Using the information contained in a cutting bill and knowledge of the lumber width distributions to be processed, thousands of possible saw spacing sequences can be reduced to a few good ones.

  12. Variable Differential Reinforcement of Other Behavior (VDRO): Its Effectiveness as a Modification Procedure.

    ERIC Educational Resources Information Center

    Reuter, Katherine E.; LeBlanc, Judith M.

    Two groups of five preschool children were trained to press a key for marbles for four sessions of variable ratio reinforcement (VR6). Subsequently, response decrement for the groups was compared during conditions of fixed and variable differential reinforcement of other behavior (DRO and VDRO). Fixed DRO was more effective for decreasing response…

  13. Response Acquisition and Fixed-Ratio Escalation Based on Interresponse Times in Rats

    ERIC Educational Resources Information Center

    Taylor, Tracy G.; Galuska, Chad M.; Banna, Kelly; Yahyavi-Firouz-Abadi, Noushin; See, Ronald E.

    2010-01-01

    The effectiveness of a fixed-ratio (FR) escalation procedure, developed by Pinkston and Branch (2004) and based on interresponse times (IRTs), was assessed during lever-press acquisition. Forty-nine experimentally naive adult male Long Evans rats were deprived of food for 24 hr prior to an extended acquisition session. Before the start of the…

  14. Sequential Tests of Multiple Hypotheses Controlling Type I and II Familywise Error Rates

    PubMed Central

    Bartroff, Jay; Song, Jinlin

    2014-01-01

    This paper addresses the following general scenario: A scientist wishes to perform a battery of experiments, each generating a sequential stream of data, to investigate some phenomenon. The scientist would like to control the overall error rate in order to draw statistically-valid conclusions from each experiment, while being as efficient as possible. The between-stream data may differ in distribution and dimension but also may be highly correlated, even duplicated exactly in some cases. Treating each experiment as a hypothesis test and adopting the familywise error rate (FWER) metric, we give a procedure that sequentially tests each hypothesis while controlling both the type I and II FWERs regardless of the between-stream correlation, and only requires arbitrary sequential test statistics that control the error rates for a given stream in isolation. The proposed procedure, which we call the sequential Holm procedure because of its inspiration from Holm’s (1979) seminal fixed-sample procedure, shows simultaneous savings in expected sample size and less conservative error control relative to fixed sample, sequential Bonferroni, and other recently proposed sequential procedures in a simulation study. PMID:25092948

  15. Case study of a central-station grid-intertie photovoltaic system with V-trough concentration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Freilich, J.; Gordon, J.M.

    1991-01-01

    This presentation is a cast study of an installed, central-station (no storage), utility-intertie photovoltaic (PV) system in Sede Boqer, Israel (latitude 30.9{degree}N). The nominally 12 kW peak PV system is comprised of 189 polycrystalline silicon modules mounted on inexpensive, one-axis north-south horizontal trackers with V-trough mirrors for optical boost. The power conditioning unit operates at a fixed voltage rather than at maximum power point (MPP). The primary task in analyzing the installed system was to investigate the cause of measured power output significantly below the design predictions of the installers, and to recommend system design modifications. Subsequent tasks included themore » quantitative assessment of fixed-voltage operation and of the energetic value of V-trough concentration and one-axis tracking for this system. Sample results show: (1) fixed-voltage operation at the best fixed voltage (BFV) can achieve around 96% of the yearly energy of MPP operation; (2) the sensitivity of the yearly energy delivery to the selection of fixed voltage and its marked asymmetry about the BFV; (3) the influences of inverter current constraints on yearly energy delivery and BFV; and (4) how the separate effects of tracking and optical concentration increase yearly energy delivery.« less

  16. Studies on utilization of treated stack gas. II. Growth of water hyacinths (Eichhornia crassipes) in carbon dioxide-rich atmospheres

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, D.F.; Hewes, K.A.

    1984-01-01

    Water hyacinths survive atmospheric carbon dioxide concentrations ranging from ambient to 15% (v/v). The optimum growth during a one-week period with continuous laboratory lighting (200 ..mu..Es/m/sup 2//sec) appeared to be about 10%. Under these conditions, the equation defining inorganic carbon fixed as a function of the atmospheric concentration of carbon dioxide indicated a maximum of about 75% of available carbon was fixed over the range 1-10% CO/sub 2/. Under a typical light cycle, the percent fixed was reduced to about 60%. The implications of the results are considered.

  17. 29 CFR 1910.24 - Fixed industrial stairs.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... OCCUPATIONAL SAFETY AND HEALTH STANDARDS Walking-Working Surfaces § 1910.24 Fixed industrial stairs. (a... load anticipated but never of less strength than to carry safely a moving concentrated load of 1,000...

  18. Water-quality assessment of the Rio Grande Valley, Colorado, New Mexico, and Texas; summary and analysis of water-quality data for the basic-fixed-site network, 1993-95

    USGS Publications Warehouse

    Healy, D.F.

    1997-01-01

    The Rio Grande Valley study unit of the U.S. Geological Survey National Water-Quality Assessment Program collected monthly water- quality samples at a network of surface-water sites from April 1993 through September 1995. This basic-fixed-site network consisted of nine main-stem sites on the Rio Grande, five sites on tributaries of the Rio Grande, two sites on streams in the Rio Grande Valley study unit that are not directly tributary to the Rio Grande, and one site on a conveyance channel. During each monthly sampling, field properties were measured and samples were collected for the analysis of dissolved solids, major constituents, nutrients, selected trace elements, and suspended-sediment concentrations. During selected samplings, supplemental samples were collected for the analysis of additional trace elements, organic carbon, and/or pesticides. Spatial variations of dissolved-solids, major-constituent, and nutrient data were analyzed. The report presents summary statistics for the monthly water-quality data by sampling site and background information on the drainage basin upstream from each site. Regression equations are presented that relate dissolved-solids, major-constituent, and nutrient concentrations to streamflow, selected field properties, and time. Median instantaneous streamflow at each basic-fixed site ranged from 1.4 to 1,380 cubic feet per second. Median specific conductance at each basic-fixed site ranged from 84 to 1,680 microsiemens per centimeter at 25 degrees Celsius, and median pH values ranged from 7.8 to 8.5. The water sampled at the basic-fixed sites generally was well oxygenated and had a median dissolved-oxygen percent of saturation range from 89 to 108. With the exception of Rio Grande above mouth of Trinchera Creek, near Lasauses, Colorado, dissolved-solids concentrations in the main stem of the Rio Grande generally increased in a downstream direction. This increase is from natural sources such as ground-water inflow and evapotranspiration and from anthropogenic sources such as irrigation- return flows, urban runoff, and wastewater-treatment plant discharges. The smallest median dissolved-solids concentration detected at a basic- fixed site was 58 milligrams per liter and the largest was 1,240 milligrams per liter. The spatial distribution of calcium, magnesium, sodium, sulfate, chloride, and fluoride was similar to the spatial distribution of dissolved solids. The spatial distribution of potassium and bicarbonate varied slightly from that of dissolved solids. Median silica concentrations generally decreased in a downstream direction. Of all cations, calcium and sodium had the largest concentrations at most basic-fixed sites. Bicarbonate and sulfate were the anions having the largest concentrations at most sites. The largest median silica concentration was at Rito de los Frijoles in Bandelier National Monument, New Mexico, where silica composed approximately 50 percent of the dissolved solids. The largest concentrations and largest median concentrations of dissolved-nutrient analytes were detected at Santa Fe River above Cochiti Lake, New Mexico, and Rio Grande at Isleta, New Mexico. The relatively large dissolved-nutrient concentrations at these sites probably were due to discharges from wastewater-treatment plants and urban runoff. The largest concentrations and largest median concentrations of total ammonia plus organic nitrogen and total phosphorus were detected at Rio Puerco near Bernardo, New Mexico. The largest concentrations of these nutrients at this site were associated with runoff from summer thunderstorms. Dissolved-iron concentrations ranged from censored concentrations to 914 micrograms per liter. Median dissolved-iron concentrations ranged from 3 to 160 micrograms per liter. Dissolved-manganese concentrations ranged from censored concent

  19. The changes in crosslink contents in tissues after formalin fixation.

    PubMed

    Abe, Masashi; Takahashi, Masaaki; Horiuchi, Kentaro; Nagano, Akira

    2003-07-01

    The aim of this study was to detect crosslinks of collagen and elastin in formalin-fixed tissue, to perform quantification of these crosslinks, and to investigate the effects of formalin fixation on crosslink contents in human yellow ligament and cartilage. Pyridinoline (Pyr) is a stable and nonreducible crosslink of collagen. Pentosidine (Pen) is a senescent crosslink formed between arginine and lysine in matrix proteins, including collagen. Desmosine (Des) and its isomer isodesmosine (Isodes) are crosslinks specifically found in elastin. It is useful to measure crosslink contents of collagen and elastin as a way of investigating the properties of various tissues or their pathological changes. If it is possible to evaluate crosslinks of collagen and elastin in formalin-fixed tissues, we can investigate crosslinks in a wide variety of tissues. We used HPLC to compare the concentrations of Pyr, Pen, Des, and Isodes in the formalin-fixed tissues with their concentrations in the frozen tissues. Pyr and Pen were detected in both the formalin-fixed yellow ligament and the cartilage, and their concentrations were not significantly affected by or related to the duration of formalin fixation. Des and Isodes were detected in the formalin-fixed yellow ligament but in significantly lower amounts compared to the frozen samples. We concluded that crosslinks of collagen were preserved in formalin, but crosslinks of elastin were not preserved in it. The reason for this might be that formalin did not fix elastin tissues sufficiently or it destroyed, masked, or altered elastin crosslinks.

  20. Energy conservation and maximal entropy production in enzyme reactions.

    PubMed

    Dobovišek, Andrej; Vitas, Marko; Brumen, Milan; Fajmut, Aleš

    2017-08-01

    A procedure for maximization of the density of entropy production in a single stationary two-step enzyme reaction is developed. Under the constraints of mass conservation, fixed equilibrium constant of a reaction and fixed products of forward and backward enzyme rate constants the existence of maximum in the density of entropy production is demonstrated. In the state with maximal density of entropy production the optimal enzyme rate constants, the stationary concentrations of the substrate and the product, the stationary product yield as well as the stationary reaction flux are calculated. The test, whether these calculated values of the reaction parameters are consistent with their corresponding measured values, is performed for the enzyme Glucose Isomerase. It is found that calculated and measured rate constants agree within an order of magnitude, whereas the calculated reaction flux and the product yield differ from their corresponding measured values for less than 20 % and 5 %, respectively. This indicates that the enzyme Glucose Isomerase, considered in a non-equilibrium stationary state, as found in experiments using the continuous stirred tank reactors, possibly operates close to the state with the maximum in the density of entropy production. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Evaluation of Trajectory Errors in an Automated Terminal-Area Environment

    NASA Technical Reports Server (NTRS)

    Oseguera-Lohr, Rosa M.; Williams, David H.

    2003-01-01

    A piloted simulation experiment was conducted to document the trajectory errors associated with use of an airplane's Flight Management System (FMS) in conjunction with a ground-based ATC automation system, Center-TRACON Automation System (CTAS) in the terminal area. Three different arrival procedures were compared: current-day (vectors from ATC), modified (current-day with minor updates), and data link with FMS lateral navigation. Six active airline pilots flew simulated arrivals in a fixed-base simulator. The FMS-datalink procedure resulted in the smallest time and path distance errors, indicating that use of this procedure could reduce the CTAS arrival-time prediction error by about half over the current-day procedure. Significant sources of error contributing to the arrival-time error were crosstrack errors and early speed reduction in the last 2-4 miles before the final approach fix. Pilot comments were all very positive, indicating the FMS-datalink procedure was easy to understand and use, and the increased head-down time and workload did not detract from the benefit. Issues that need to be resolved before this method of operation would be ready for commercial use include development of procedures acceptable to controllers, better speed conformance monitoring, and FMS database procedures to support the approach transitions.

  2. Adequacy of Fixed-Dose Heparin Infusions for Venous Thromboembolism Prevention after Microsurgical Procedures.

    PubMed

    Bertolaccini, Corinne M; Prazak, Ann Marie B; Agarwal, Jayant; Goodwin, Isak A; Rockwell, W Bradford; Pannucci, Christopher J

    2018-05-22

     In microvascular surgery, patients often receive unfractionated heparin infusions to minimize risk for microvascular thrombosis. Patients who receive intravenous (IV) heparin are believed to have adequate prophylaxis against venous thromboembolism (VTE). Whether a fixed dose of IV heparin provides detectable levels of anticoagulation, or whether the "one size fits all" approach provides adequate prophylaxis against VTE remains unknown. This study examined the pharmacodynamics of fixed-dose heparin infusions and the effects of real-time, anti-factor Xa (aFXa) level driven heparin dose adjustments.  This prospective clinical trial recruited adult microvascular surgery patients placed on a fixed-dose (500 units/h) unfractionated heparin infusion during their initial microsurgical procedure. Steady-state aFXa levels, a marker of unfractionated heparin efficacy and safety, were monitored. Patients with out-of-range aFXa levels received protocol-driven real-time dose adjustments. Outcomes of interest included aFXa levels in response to heparin 500 units/h, number of dose adjustments required to achieve goal aFXa levels, time to reach goal aFXa level, and 90-day clinically relevant bleeding and VTE.  Twenty patients were recruited prospectively. None of 20 patients had any detectable level of anticoagulation in response to heparin infusions at 500 units/h. The median number of dose adjustments required to reach goal level was five, and median weight-based dose to reach goal level was 11.8 units/kg/h. Real-time dose adjustments significantly increased the proportion of patients with in-range levels (60 vs. 0%, p  = 0.0001). The 90-day VTE rate was 5% and 90-day clinically relevant bleeding rate was 5%.  Fixed-dose heparin infusions at a rate of 500 units/h do not provide a detectable level of anticoagulation after microsurgical procedures and are insufficient for the majority of patients who require VTE prophylaxis. Weight-based heparin infusions at 10 to 12 units/kg/h deserve future study in patients undergoing microsurgical procedures to increase the proportion of patients receiving adequate VTE prophylaxis. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  3. Evaluation of the Effect of the CO2 Ocean Sequestration on Marine Life in the Sea near Japan Using a Numerical Model

    NASA Astrophysics Data System (ADS)

    Nakamura, Tomoaki; Wada, Akira; Hasegawa, Kazuyuki; Ochiai, Minoru

    CO2 oceanic sequestration is one of the technologies for reducing the discharge of CO2 into the atmosphere, which is considered to cause the global warming, and consists in isolating industry-made CO2 gas within the depths of the ocean. This method is expected to enable industry-made CO2 to be separated from the atmosphere for a considerably long period of time. On the other hand, it is also feared that the CO2 injected in the ocean may lower pH of seawater surrounding the sequestration site, thus may adversely affect marine organisms. For evaluating the biological influences, we have studied to precisely predict the CO2 distribution around the CO2 injection site by a numerical simulation method. In previous studies, in which a 2 degree by 2 degree mesh was employed in the simulation, CO2 concentrations tended to be evenly dispersed within the grid, giving lower concentration values. Thus, the calculation accuracy within the area several hundred kilometers from the CO2 injection site was not satisfactory for the biological effect assessment. In the present study, we improved the accuracy of concentration distribution by changing the computational mesh resolution for a 0.2 by 0.2 degree. By the renewed method we could obtain detailed CO2 distribution in waters within several hundred kilometers of the injection site, and clarified that the Moving-ship procedure may have less effects of lowered pH on marine organisms than the fixed-point release procedure of CO2 sequestration.

  4. Concentration of Access to Information and Communication Technologies in the Municipalities of the Brazilian Legal Amazon.

    PubMed

    de Brito, Silvana Rossy; da Silva, Aleksandra do Socorro; Cruz, Adejard Gaia; Monteiro, Maurílio de Abreu; Vijaykumar, Nandamudi Lankalapalli; da Silva, Marcelino Silva; Costa, João Crisóstomo Weyl Albuquerque; Francês, Carlos Renato Lisboa

    2016-01-01

    This study fills demand for data on access and use of information and communication technologies (ICT) in the Brazilian legal Amazon, a region of localities with identical economic, political, and social problems. We use the 2010 Brazilian Demographic Census to compile data on urban and rural households (i) with computers and Internet access, (ii) with mobile phones, and (iii) with fixed phones. To compare the concentration of access to ICT in the municipalities of the Brazilian Amazon with other regions of Brazil, we use a concentration index to quantify the concentration of households in the following classes: with computers and Internet access, with mobile phones, with fixed phones, and no access. These data are analyzed along with municipal indicators on income, education, electricity, and population size. The results show that for urban households, the average concentration in the municipalities of the Amazon for computers and Internet access and for fixed phones is lower than in other regions of the country; meanwhile, that for no access and mobile phones is higher than in any other region. For rural households, the average concentration in the municipalities of the Amazon for computers and Internet access, mobile phones, and fixed phones is lower than in any other region of the country; meanwhile, that for no access is higher than in any other region. In addition, the study shows that education and income are determinants of inequality in accessing ICT in Brazilian municipalities and that the existence of electricity in rural households is directly associated with the ownership of ICT resources.

  5. Concentration of Access to Information and Communication Technologies in the Municipalities of the Brazilian Legal Amazon

    PubMed Central

    de Brito, Silvana Rossy; da Silva, Aleksandra do Socorro; Cruz, Adejard Gaia; Monteiro, Maurílio de Abreu; Vijaykumar, Nandamudi Lankalapalli; da Silva, Marcelino Silva; Costa, João Crisóstomo Weyl Albuquerque; Francês, Carlos Renato Lisboa

    2016-01-01

    This study fills demand for data on access and use of information and communication technologies (ICT) in the Brazilian legal Amazon, a region of localities with identical economic, political, and social problems. We use the 2010 Brazilian Demographic Census to compile data on urban and rural households (i) with computers and Internet access, (ii) with mobile phones, and (iii) with fixed phones. To compare the concentration of access to ICT in the municipalities of the Brazilian Amazon with other regions of Brazil, we use a concentration index to quantify the concentration of households in the following classes: with computers and Internet access, with mobile phones, with fixed phones, and no access. These data are analyzed along with municipal indicators on income, education, electricity, and population size. The results show that for urban households, the average concentration in the municipalities of the Amazon for computers and Internet access and for fixed phones is lower than in other regions of the country; meanwhile, that for no access and mobile phones is higher than in any other region. For rural households, the average concentration in the municipalities of the Amazon for computers and Internet access, mobile phones, and fixed phones is lower than in any other region of the country; meanwhile, that for no access is higher than in any other region. In addition, the study shows that education and income are determinants of inequality in accessing ICT in Brazilian municipalities and that the existence of electricity in rural households is directly associated with the ownership of ICT resources. PMID:27035577

  6. A statistical evaluation of the effects of gender differences in assessment of acute inhalation toxicity

    PubMed Central

    Price, Charlotte; Stallard, Nigel; Creton, Stuart; Indans, Ian; Guest, Robert; Griffiths, David; Edwards, Philippa

    2010-01-01

    Acute inhalation toxicity of chemicals has conventionally been assessed by the median lethal concentration (LC50) test (organisation for economic co-operation and development (OECD) TG 403). Two new methods, the recently adopted acute toxic class method (ATC; OECD TG 436) and a proposed fixed concentration procedure (FCP), have recently been considered, but statistical evaluations of these methods did not investigate the influence of differential sensitivity between male and female rats on the outcomes. This paper presents an analysis of data from the assessment of acute inhalation toxicity for 56 substances. Statistically significant differences between the LC50 for males and females were found for 16 substances, with greater than 10-fold differences in the LC50 for two substances. The paper also reports a statistical evaluation of the three test methods in the presence of unanticipated gender differences. With TG 403, a gender difference leads to a slightly greater chance of under-classification. This is also the case for the ATC method, but more pronounced than for TG 403, with misclassification of nearly all substances from Globally Harmonised System (GHS) class 3 into class 4. As the FCP uses females only, if females are more sensitive, the classification is unchanged. If males are more sensitive, the procedure may lead to under-classification. Additional research on modification of the FCP is thus proposed. PMID:20488841

  7. 10 CFR 73.46 - Fixed site physical protection systems, subsystems, components, and procedures.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., components, and procedures. 73.46 Section 73.46 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) PHYSICAL... Energy couriers engaged in the transport of special nuclear material. The search function for detection... of Energy vehicles engaged in transporting special nuclear material and emergency vehicles under...

  8. 10 CFR 73.46 - Fixed site physical protection systems, subsystems, components, and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., components, and procedures. 73.46 Section 73.46 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) PHYSICAL... Energy couriers engaged in the transport of special nuclear material. The search function for detection... of Energy vehicles engaged in transporting special nuclear material and emergency vehicles under...

  9. Rapid Acquisition of Preference in Concurrent Chains: Effects of "d"-Amphetamine on Sensitivity to Reinforcement Delay

    ERIC Educational Resources Information Center

    Ta, Wei-Min; Pitts, Raymond C.; Hughes, Christine E.; McLean, Anthony P.; Grace, Randolph C.

    2008-01-01

    The purpose of this study was to examine effects of "d"-amphetamine on choice controlled by reinforcement delay. Eight pigeons responded under a concurrent-chains procedure in which one terminal-link schedule was always fixed- interval 8 s, and the other terminal-link schedule changed from session to session between fixed-interval 4 s and…

  10. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION OF FIXED SITE INDOOR AND OUTDOOR FORMALDEHYDE PASSIVE SAMPLES (UA-F-13.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the methods used to sample residential indoor and outdoor atmospheres for the presence of formaldehyde using the PF-1 passive formaldehyde sampler. The PF-1 passive sampler is used as a fixed location monitor to determine time integrated ex...

  11. Multistep integration formulas for the numerical integration of the satellite problem

    NASA Technical Reports Server (NTRS)

    Lundberg, J. B.; Tapley, B. D.

    1981-01-01

    The use of two Class 2/fixed mesh/fixed order/multistep integration packages of the PECE type for the numerical integration of the second order, nonlinear, ordinary differential equation of the satellite orbit problem. These two methods are referred to as the general and the second sum formulations. The derivation of the basic equations which characterize each formulation and the role of the basic equations in the PECE algorithm are discussed. Possible starting procedures are examined which may be used to supply the initial set of values required by the fixed mesh/multistep integrators. The results of the general and second sum integrators are compared to the results of various fixed step and variable step integrators.

  12. Principles of quantitation of viral loads using nucleic acid sequence-based amplification in combination with homogeneous detection using molecular beacons.

    PubMed

    Weusten, Jos J A M; Carpay, Wim M; Oosterlaken, Tom A M; van Zuijlen, Martien C A; van de Wiel, Paul A

    2002-03-15

    For quantitative NASBA-based viral load assays using homogeneous detection with molecular beacons, such as the NucliSens EasyQ HIV-1 assay, a quantitation algorithm is required. During the amplification process there is a constant growth in the concentration of amplicons to which the beacon can bind while generating a fluorescence signal. The overall fluorescence curve contains kinetic information on both amplicon formation and beacon binding, but only the former is relevant for quantitation. In the current paper, mathematical modeling of the relevant processes is used to develop an equation describing the fluorescence curve as a function of the amplification time and the relevant kinetic parameters. This equation allows reconstruction of RNA formation, which is characterized by an exponential increase in concentrations as long as the primer concentrations are not rate limiting and by linear growth over time after the primer pool is depleted. During the linear growth phase, the actual quantitation is based on assessing the amplicon formation rate from the viral RNA relative to that from a fixed amount of calibrator RNA. The quantitation procedure has been successfully applied in the NucliSens EasyQ HIV-1 assay.

  13. A fuzzy-logic-based controller for methane production in anaerobic fixed-film reactors.

    PubMed

    Robles, A; Latrille, E; Ruano, M V; Steyer, J P

    2017-01-01

    The main objective of this work was to develop a controller for biogas production in continuous anaerobic fixed-bed reactors, which used effluent total volatile fatty acids (VFA) concentration as control input in order to prevent process acidification at closed loop. To this aim, a fuzzy-logic-based control system was developed, tuned and validated in an anaerobic fixed-bed reactor at pilot scale that treated industrial winery wastewater. The proposed controller varied the flow rate of wastewater entering the system as a function of the gaseous outflow rate of methane and VFA concentration. Simulation results show that the proposed controller is capable to achieve great process stability even when operating at high VFA concentrations. Pilot results showed the potential of this control approach to maintain the process working properly under similar conditions to the ones expected at full-scale plants.

  14. The Rhetoric of the Resume.

    ERIC Educational Resources Information Center

    Anderson, W. Steve

    Faithfully following a fixed set of procedures has long been standard practice in writing resumes. This process produces a passable document with a minimum of effort expended. There are, however, advantages to be gained from taking a conceptual approach to resume preparation. First, it can help provide a framework for these procedures, giving the…

  15. ATC simulation of helicopter IFR approaches into major terminal areas using RNAV, MLS, and CDTI

    NASA Technical Reports Server (NTRS)

    Tobias, L.; Lee, H. Q.; Peach, L. L.; Willett, F. M., Jr.; Obrien, P. J.

    1981-01-01

    The introduction of independent helicopter IFR routes at hub airports was investigated in a real time air traffic control system simulation involving a piloted helicopter simulator, computer generated air traffic, and air traffic controllers. The helicopter simulator was equipped to fly area navigation (RNAV) routes and microwave landing system approaches. Problems studied included: (1) pilot acceptance of the approach procedure and tracking accuracy; (2) ATC procedures for handling a mix of helicopter and fixed wing traffic; and (3) utility of the cockpit display of traffic information (CDTI) for the helicopter in the hub airport environment. Results indicate that the helicopter routes were acceptable to the subject pilots and were noninterfering with fixed wing traffic. Merging and spacing maneuvers using CDTI were successfully carried out by the pilots, but controllers had some reservations concerning the acceptability of the CDTI procedures.

  16. A Laboratory Manual for Stepwise Cerebral White Matter Fiber Dissection.

    PubMed

    Koutsarnakis, Christos; Liakos, Faidon; Kalyvas, Aristotelis V; Sakas, Damianos E; Stranjalis, George

    2015-08-01

    White matter fiber dissection is an important method in acquiring a thorough neuroanatomic knowledge for surgical practice. Previous studies have definitely improved our understanding of intrinsic brain anatomy and emphasized on the significance of this technique in modern neurosurgery. However, current literature lacks a complete and concentrated laboratory guide about the entire dissection procedure. Hence, our primary objective is to introduce a detailed laboratory manual for cerebral white matter dissection by highlighting consecutive dissection steps, and to stress important technical comments facilitating this complex procedure. Twenty adult, formalin-fixed cerebral hemispheres were included in the study. Ten specimens were dissected in the lateromedial and 10 in the mediolateral direction, respectively, using the fiber dissection technique and the microscope. Eleven and 8 consecutive and distinctive dissection steps are recommended for the lateromedial and mediolateral dissection procedures, respectively. Photographs highlighting various anatomic landmarks accompany every step. Technical recommendations, facilitating the dissection process, are also indicated. The fiber dissection technique, although complex and time consuming, offers a three-dimensional knowledge of intrinsic brain anatomy and architecture, thus improving both the quality of microneurosurgery and the patient's standard of care. The present anatomic study provides a thorough dissection manual to those who study brain anatomy using this technique. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. A two-phased fuzzy decision making procedure for IT supplier selection

    NASA Astrophysics Data System (ADS)

    Shohaimay, Fairuz; Ramli, Nazirah; Mohamed, Siti Rosiah; Mohd, Ainun Hafizah

    2013-09-01

    In many studies on fuzzy decision making, linguistic terms are usually represented by corresponding fixed triangular or trapezoidal fuzzy numbers. However, the fixed fuzzy numbers used in decision making process may not explain the actual respondents' opinions. Hence, a two-phased fuzzy decision making procedure is proposed. First, triangular fuzzy numbers were built based on respondents' opinions on the appropriate range (0-100) for each seven-scale linguistic terms. Then, the fuzzy numbers were integrated into fuzzy decision making model. The applicability of the proposed method is demonstrated in a case study of supplier selection in Information Technology (IT) department. The results produced via the developed fuzzy numbers were consistent with the results obtained using fixed fuzzy numbers. However, with different set of fuzzy numbers based on respondents, there is a difference in the ranking of suppliers based on criterion X1 (background of supplier). Hopefully the proposed model which incorporates fuzzy numbers based on respondents will provide a more significant meaning towards future decision making.

  18. Wide-angle planar microtracking for quasi-static microcell concentrating photovoltaics

    NASA Astrophysics Data System (ADS)

    Price, Jared S.; Sheng, Xing; Meulblok, Bram M.; Rogers, John A.; Giebink, Noel C.

    2015-02-01

    Concentrating photovoltaics offer a way to lower the cost of solar power. However, the existing paradigm based on precise orientation of large-area concentrator modules towards the Sun limits their deployment to large, open land areas. Here, we explore an alternate approach using high-efficiency microcell photovoltaics embedded between a pair of plastic lenslet arrays to demonstrate quasi-static concentrating photovoltaic panels <1 cm thick that accomplish full-day tracking with >200x flux concentration ratio through small (<1 cm) lateral translation at fixed latitude tilt. Per unit of installed land area, cosine projection loss for fixed microtracking concentrating photovoltaic panels is ultimately offset by improved ground coverage relative to their conventional dual-axis counterparts, enabling a ~1.9x increase in daily energy output that may open up a new opportunity for compact, high-efficiency concentrating photovoltaics to be installed on rooftops and other limited-space urban environments.

  19. Wide-angle planar microtracking for quasi-static microcell concentrating photovoltaics.

    PubMed

    Price, Jared S; Sheng, Xing; Meulblok, Bram M; Rogers, John A; Giebink, Noel C

    2015-02-05

    Concentrating photovoltaics offer a way to lower the cost of solar power. However, the existing paradigm based on precise orientation of large-area concentrator modules towards the Sun limits their deployment to large, open land areas. Here, we explore an alternate approach using high-efficiency microcell photovoltaics embedded between a pair of plastic lenslet arrays to demonstrate quasi-static concentrating photovoltaic panels <1 cm thick that accomplish full-day tracking with >200x flux concentration ratio through small (<1 cm) lateral translation at fixed latitude tilt. Per unit of installed land area, cosine projection loss for fixed microtracking concentrating photovoltaic panels is ultimately offset by improved ground coverage relative to their conventional dual-axis counterparts, enabling a ~1.9x increase in daily energy output that may open up a new opportunity for compact, high-efficiency concentrating photovoltaics to be installed on rooftops and other limited-space urban environments.

  20. Competition effects in cation binding to humic acid: Conditional affinity spectra for fixed total metal concentration conditions

    NASA Astrophysics Data System (ADS)

    David, Calin; Mongin, Sandrine; Rey-Castro, Carlos; Galceran, Josep; Companys, Encarnació; Garcés, José Luis; Salvador, José; Puy, Jaume; Cecilia, Joan; Lodeiro, Pablo; Mas, Francesc

    2010-09-01

    Information on the Pb and Cd binding to a purified Aldrich humic acid (HA) is obtained from the influence of different fixed total metal concentrations on the acid-base titrations of this ligand. NICA (Non-Ideal Competitive Adsorption) isotherm has been used for a global quantitative description of the binding, which has then been interpreted by plotting the Conditional Affinity Spectra of the H + binding at fixed total metal concentrations (CAScTM). This new physicochemical tool, here introduced, allows the interpretation of binding results in terms of distributions of proton binding energies. A large increase in the acidity of the phenolic sites as the total metal concentration increases, especially in presence of Pb, is revealed from the shift of the CAScTM towards lower affinities. The variance of the CAScTM distribution, which can be used as a direct measure of the heterogeneity, also shows a significant dependence on the total metal concentration. A discussion of the factors that influence the heterogeneity of the HA under the conditions of each experiment is provided, so that the smoothed pattern exhibited by the titration curves can be justified.

  1. Adsorption of ciprofloxacin and norfloxacin from aqueous solution onto granular activated carbon in fixed bed column.

    PubMed

    Darweesh, Teeba M; Ahmed, Muthanna J

    2017-04-01

    Carbonization of Phoenix dactylifera L stones followed by microwave K 2 CO 3 activation was adopted for preparation of granular activated carbon (KAC). High yield and favorable pore characteristics in terms of surface area and pore volume were reported for KAC as follows: 44%, 852m 2 /g, and 0.671cm 3 /g, respectively. The application of KAC as adsorbent for attraction of ciprofloxacin (CIP) and norfloxacin (NOR) was investigated using fixed bed systems. The effect of flow rate (0.5-1.5ml/min), bed height (15-25cm), and initial drug concentration (75-225mg/l) on the behavior of breakthrough curves was explained. The fixed bed analysis showed the better correlation of breakthrough data by both Thomas and Yoon-Nelson models. Inlet drug concentration was of greatest effect on breakthrough data compared to other fixed bed variables. Experimental and calculated breakthrough data were obtained for CIP and NOR adsorption on KAC, thus being important for design of fixed bed column. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Plant assemblage composition and soil P concentration differentially affect communities of AM and total fungi in a semi-arid grassland.

    PubMed

    Klabi, Rim; Bell, Terrence H; Hamel, Chantal; Iwaasa, Alan; Schellenberg, Mike; Raies, Aly; St-Arnaud, Marc

    2015-01-01

    Adding inorganic P- and N-fixing legumes to semi-arid grasslands can increase forage yield, but soil nutrient concentrations and plant cover may also interact to modify soil fungal populations, impacting short- and long-term forage production. We tested the effect of plant assemblage (seven native grasses, seven native grasses + the domesticated N-fixing legume Medicago sativa, seven native grasses + the native N-fixing legume Dalea purpurea or the introduced grass Bromus biebersteinii + M. sativa) and soil P concentration (addition of 0 or 200 P2O5 kg ha(-1) at sowing) on the diversity and community structure of arbuscular mycorrhizal (AM) fungi and total fungi over two consecutive years, using 454-pyrosequencing of 18S rDNA and ITS amplicons. Treatment effects were stronger in the wet year (2008) than the dry year (2009). The presence of an N-fixing legume with native grasses generally increased AM fungal diversity, while the interaction between soil P concentration and plant assemblage modified total fungal community structure in 2008. Excluding interannual variations, which are likely driven by moisture and plant productivity, AM fungal communities in semi-arid grasslands appear to be primarily affected by plant assemblage composition, while the composition of other fungi is more closely linked to soil P. © FEMS 2014. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. Medial Patellofemoral Ligament Reconstruction Procedure Using a Suspensory Femoral Fixation System

    PubMed Central

    Nakagawa, Shuji; Arai, Yuji; Kan, Hiroyuki; Ueshima, Keiichiro; Ikoma, Kazuya; Terauchi, Ryu; Kubo, Toshikazu

    2013-01-01

    Recurrent patellar dislocation has recently been treated with anatomic medial patellofemoral ligament (MPFL) reconstruction using a semitendinosus muscle tendon. Although it is necessary to add tension to fix the tendon graft without loading excess stress on the patellofemoral joint, adjustment of the tension can be difficult. To resolve this problem, we developed an MPFL reconstruction procedure using the ToggleLoc Fixation Device (Biomet, Warsaw, IN), in which the semitendinosus muscle tendon is folded and used as a double-bundle tendon graft and 2 bone tunnels and 1 bone tunnel are made on the patellar and femoral sides, respectively. The patellar side of the tendon graft is fixed with an EndoButton (Smith & Nephew, London, England), and the femoral side is fixed with the ToggleLoc. Stepless adjustment of tension of the tendon graft is possible by reducing the size of the loop of the ToggleLoc hung onto the tendon graft. It may be useful to position the patella in the center of the femoral sulcus by confirming the patellofemoral joint fitting. Stability can be confirmed by loading lateral stress on the patella in the extended knee joint. This procedure is less invasive because opening of the lateral side of the femur is not necessary, and it may be useful for MPFL reconstruction. PMID:24892014

  4. Assessing total fungal concentrations on commercial passenger aircraft using mixed-effects modeling.

    PubMed

    McKernan, Lauralynn Taylor; Hein, Misty J; Wallingford, Kenneth M; Burge, Harriet; Herrick, Robert

    2008-01-01

    The primary objective of this study was to compare airborne fungal concentrations onboard commercial passenger aircraft at various in-flight times with concentrations measured inside and outside airport terminals. A secondary objective was to investigate the use of mixed-effects modeling of repeat measures from multiple sampling intervals and locations. Sequential triplicate culturable and total spore samples were collected on wide-body commercial passenger aircraft (n = 12) in the front and rear of coach class during six sampling intervals: boarding, midclimb, early cruise, midcruise, late cruise, and deplaning. Comparison samples were collected inside and outside airport terminals at the origin and destination cities. The MIXED procedure in SAS was used to model the mean and the covariance matrix of the natural log transformed fungal concentrations. Five covariance structures were tested to determine the appropriate models for analysis. Fixed effects considered included the sampling interval and, for samples obtained onboard the aircraft, location (front/rear of coach section), occupancy rate, and carbon dioxide concentrations. Overall, both total culturable and total spore fungal concentrations were low while the aircraft were in flight. No statistical difference was observed between measurements made in the front and rear sections of the coach cabin for either culturable or total spore concentrations. Both culturable and total spore concentrations were significantly higher outside the airport terminal compared with inside the airport terminal (p-value < 0.0001) and inside the aircraft (p-value < 0.0001). On the aircraft, the majority of total fungal exposure occurred during the boarding and deplaning processes, when the aircraft utilized ancillary ventilation and passenger activity was at its peak.

  5. Modelling the effects of PSII inhibitor pulse exposure on two algae in co-culture.

    PubMed

    Copin, Pierre-Jean; Chèvre, Nathalie

    2018-03-01

    A weakness of standard testing procedures is that they do not consider interactions between organisms, and they focus only on single species. Furthermore, these procedures do not take into account pulse exposure. However, pulse exposure is of particular importance because in streams, after crop application and during and after precipitation, herbicide concentrations fluctuate widely and can exceed the Annual Average Environmental Quality Standards (AA-EQS), which aim to protect the aquatic environment. The sensitivity of the algae Scenedesmus vacuolatus and Pseudokirchneriella subcapitata in a co-culture exposed to pulses is thus analysed in this study. As a first step, the growths of the algae in co-culture are investigated. For initial cell densities fixed, respectively, to 100,000 and 50,000 cells/mL, the growth of each alga is exponential over at least 48 h. S. vacuolatus seems to influence the growth of P. subcapitata negatively. Allelopathy is a possible explanation for this growth inhibition. The toxicity of the herbicide isoproturon is later tested on the algae S. vacuolatus and P. subcapitata cultured alone and in the co-culture. Despite the supplementary stress on the algae in the co-culture competing for nutrients, the toxicity of the herbicide is lower for the two algae when they are in the co-culture than when they are in separated culture. A model is adapted and used to predict the cell-density inhibition on the alga S. vacuolatus in the co-culture with the alga P. subcapitata exposed to a pulse concentration of isoproturon. Four laboratory experiments are performed to validate the model. The comparison between the laboratory and the modelled effects shows good agreement. The differences can be considered minor most of time. For future studies, it is important to ensure that the cell count is precise, as it is used to determine the parameters of the model. The differences can be also induced by the fact that the cell number of the alga P. subcapitata re-suspended in a new OECD medium after the centrifugation process cannot be fixed.

  6. Image discrimination models predict detection in fixed but not random noise

    NASA Technical Reports Server (NTRS)

    Ahumada, A. J. Jr; Beard, B. L.; Watson, A. B. (Principal Investigator)

    1997-01-01

    By means of a two-interval forced-choice procedure, contrast detection thresholds for an aircraft positioned on a simulated airport runway scene were measured with fixed and random white-noise masks. The term fixed noise refers to a constant, or unchanging, noise pattern for each stimulus presentation. The random noise was either the same or different in the two intervals. Contrary to simple image discrimination model predictions, the same random noise condition produced greater masking than the fixed noise. This suggests that observers seem unable to hold a new noisy image for comparison. Also, performance appeared limited by internal process variability rather than by external noise variability, since similar masking was obtained for both random noise types.

  7. 75 FR 54675 - Self-Regulatory Organizations; Fixed Income Clearing Corporation; Notice of Filing and Immediate...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-08

    ... waive FICC's rules, procedures, and regulations of the Mortgage-Backed Securities Division. II. Self... SECURITIES AND EXCHANGE COMMISSION [Release No. 34-62796; File No. SR-FICC-2010-06] Self... Proposed Rule Change To Amend Rules Relating to Authority To Waive Rules, Procedures, and Regulations of...

  8. Comparing the Performance of Five Multidimensional CAT Selection Procedures with Different Stopping Rules

    ERIC Educational Resources Information Center

    Yao, Lihua

    2013-01-01

    Through simulated data, five multidimensional computerized adaptive testing (MCAT) selection procedures with varying test lengths are examined and compared using different stopping rules. Fixed item exposure rates are used for all the items, and the Priority Index (PI) method is used for the content constraints. Two stopping rules, standard error…

  9. 47 CFR 25.261 - Procedures for avoidance of in-line interference events for Non Geostationary Satellite Orbit...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... interference events for Non Geostationary Satellite Orbit (NGSO) Satellite Network Operations in the Fixed... avoidance of in-line interference events for Non Geostationary Satellite Orbit (NGSO) Satellite Network... procedures in this section apply to non-Federal-Government NGSO FSS satellite networks operating in the...

  10. 47 CFR 25.261 - Procedures for avoidance of in-line interference events for Non Geostationary Satellite Orbit...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... interference events for Non Geostationary Satellite Orbit (NGSO) Satellite Network Operations in the Fixed... avoidance of in-line interference events for Non Geostationary Satellite Orbit (NGSO) Satellite Network... procedures in this section apply to non-Federal-Government NGSO FSS satellite networks operating in the...

  11. CTEPP STANDARD OPERATING PROCEDURE FOR COLLECTION OF FIXED SITE INDOOR AND OUTDOOR AIR SAMPLES FOR PERSISTENT ORGANIC POLLUTANTS (SOP-2.12)

    EPA Science Inventory

    This SOP describes the procedures to set up, calibrate, initiate and terminate air sampling for persistent organic pollutants. This method is used to sample air, indoors and outdoors, at homes and at day care centers over a 48-hr period.

  12. A Comparison of Exposure Control Procedures in CATS Using the GPC Model

    ERIC Educational Resources Information Center

    Leroux, Audrey J.; Dodd, Barbara G.

    2016-01-01

    The current study compares the progressive-restricted standard error (PR-SE) exposure control method with the Sympson-Hetter, randomesque, and no exposure control (maximum information) procedures using the generalized partial credit model with fixed- and variable-length CATs and two item pools. The PR-SE method administered the entire item pool…

  13. 47 CFR 25.261 - Procedures for avoidance of in-line interference events for Non Geostationary Satellite Orbit...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 2 2014-10-01 2014-10-01 false Procedures for avoidance of in-line interference events for Non Geostationary Satellite Orbit (NGSO) Satellite Network Operations in the Fixed... avoidance of in-line interference events for Non Geostationary Satellite Orbit (NGSO) Satellite Network...

  14. 47 CFR 25.261 - Procedures for avoidance of in-line interference events for Non Geostationary Satellite Orbit...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 2 2012-10-01 2012-10-01 false Procedures for avoidance of in-line interference events for Non Geostationary Satellite Orbit (NGSO) Satellite Network Operations in the Fixed... avoidance of in-line interference events for Non Geostationary Satellite Orbit (NGSO) Satellite Network...

  15. 47 CFR 25.261 - Procedures for avoidance of in-line interference events for Non Geostationary Satellite Orbit...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 2 2013-10-01 2013-10-01 false Procedures for avoidance of in-line interference events for Non Geostationary Satellite Orbit (NGSO) Satellite Network Operations in the Fixed... avoidance of in-line interference events for Non Geostationary Satellite Orbit (NGSO) Satellite Network...

  16. 78 FR 42809 - Self-Regulatory Organizations; Fixed Income Clearing Corporation; Order Approving Proposed Rule...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-17

    ... remain subject to all of the GSD's normal risk management procedures, which include marking member portfolios to the market on an intraday basis and charging variation margins accordingly.\\19\\ These risk management procedures should help ensure the safety of the securities and funds handled by the GSD in...

  17. 21 CFR 1315.23 - Procedure for fixing individual manufacturing quotas.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... IMPORTATION AND PRODUCTION QUOTAS FOR EPHEDRINE, PSEUDOEPHEDRINE, AND PHENYLPROPANOLAMINE Individual... manufacturing quotas for ephedrine, pseudoephedrine, and phenylpropanolamine, the Administrator shall allocate...

  18. 21 CFR 1315.23 - Procedure for fixing individual manufacturing quotas.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... IMPORTATION AND PRODUCTION QUOTAS FOR EPHEDRINE, PSEUDOEPHEDRINE, AND PHENYLPROPANOLAMINE Individual... manufacturing quotas for ephedrine, pseudoephedrine, and phenylpropanolamine, the Administrator shall allocate...

  19. 21 CFR 1315.23 - Procedure for fixing individual manufacturing quotas.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... IMPORTATION AND PRODUCTION QUOTAS FOR EPHEDRINE, PSEUDOEPHEDRINE, AND PHENYLPROPANOLAMINE Individual... manufacturing quotas for ephedrine, pseudoephedrine, and phenylpropanolamine, the Administrator shall allocate...

  20. 21 CFR 1315.23 - Procedure for fixing individual manufacturing quotas.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... IMPORTATION AND PRODUCTION QUOTAS FOR EPHEDRINE, PSEUDOEPHEDRINE, AND PHENYLPROPANOLAMINE Individual... manufacturing quotas for ephedrine, pseudoephedrine, and phenylpropanolamine, the Administrator shall allocate...

  1. 48 CFR 731.370 - Predetermined fixed rates for indirect costs.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... INTERNATIONAL DEVELOPMENT GENERAL CONTRACTING REQUIREMENTS CONTRACT COST PRINCIPLES AND PROCEDURES Contracts... determining the indirect costs applicable under contracts with educational institutions. ...

  2. 48 CFR 731.370 - Predetermined fixed rates for indirect costs.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... INTERNATIONAL DEVELOPMENT GENERAL CONTRACTING REQUIREMENTS CONTRACT COST PRINCIPLES AND PROCEDURES Contracts... determining the indirect costs applicable under contracts with educational institutions. ...

  3. In vitro growth and maturation of isolated caprine preantral follicles: Influence of insulin and FSH concentration, culture dish, coculture, and oocyte size on meiotic resumption.

    PubMed

    Silva, G M; Brito, I R; Sales, A D; Aguiar, F L N; Duarte, A B G; Araújo, V R; Vieira, L A; Magalhães-Padilha, D M; Lima, L F; Alves, B G; Silveira, L B R; Lo Turco, E G; Rodrigues, A P; Campello, C C; Wheeler, M B; Figueiredo, J R

    2017-03-01

    The aims of this study were: (1) to evaluate the effect of different insulin concentrations, alone or in combination with either a fixed FSH concentration or increasing FSH concentrations on the in vitro culture of isolated caprine preantral follicles and (2) to analyze the efficiency of two IVM media and maturation culture systems (with or without coculture with in vivo grown oocytes) on the meiosis resumption. Secondary follicles were cultured for 18 days in a basic medium supplemented with low- or high-insulin concentration alone or with a fixed FSH concentration or with increasing FSH concentrations. Oocytes grown in vivo or in vitro were matured alone or cocultured. The high-insulin concentration associated with fixed FSH treatment had higher meiotic resumption rate (P < 0.05) and was the only treatment capable of producing oocytes in metaphase II. The rates of germinal vesicle, germinal vesicle breakdown, metaphase I, metaphase II (MII), meiotic resumption, and oocyte diameter were similar between the maturation media. In conclusion, a basic medium supplemented with 10-μg/mL insulin and 100-μg/mL FSH throughout the culture period improved meiotic resumption rate and produced MII oocytes from caprine preantral follicles cultured in vitro. The MII rate was similar between in vivo and in vitro grown oocytes ≥110 μm. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Quantifying spatiotemporal variability of fine particles in an urban environment using combined fixed and mobile measurements

    NASA Astrophysics Data System (ADS)

    Sullivan, R. C.; Pryor, S. C.

    2014-06-01

    Spatiotemporal variability of fine particle concentrations in Indianapolis, Indiana is quantified using a combination of high temporal resolution measurements at four fixed sites and mobile measurements with instruments attached to bicycles during transects of the city. Average urban PM2.5 concentrations are an average of ˜3.9-5.1 μg m-3 above the regional background. The influence of atmospheric conditions on ambient PM2.5 concentrations is evident with the greatest temporal variability occurring at periods of one day and 5-10 days corresponding to diurnal and synoptic meteorological processes, and lower mean wind speeds are associated with episodes of high PM2.5 concentrations. An anthropogenic signal is also evident. Higher PM2.5 concentrations coincide with morning rush hour, the frequencies of PM2.5 variability co-occur with those for carbon monoxide, and higher extreme concentrations were observed mid-week compared to weekends. On shorter time scales (

  5. Wall shear stress fixed points in blood flow

    NASA Astrophysics Data System (ADS)

    Arzani, Amirhossein; Shadden, Shawn

    2017-11-01

    Patient-specific computational fluid dynamics produces large datasets, and wall shear stress (WSS) is one of the most important parameters due to its close connection with the biological processes at the wall. While some studies have investigated WSS vectorial features, the WSS fixed points have not received much attention. In this talk, we will discuss the importance of WSS fixed points from three viewpoints. First, we will review how WSS fixed points relate to the flow physics away from the wall. Second, we will discuss how certain types of WSS fixed points lead to high biochemical surface concentration in cardiovascular mass transport problems. Finally, we will introduce a new measure to track the exposure of endothelial cells to WSS fixed points.

  6. Two Fixed, Evacuated, Glass, Solar Collectors Using Nonimaging Concentration

    NASA Astrophysics Data System (ADS)

    Garrison, John D.; Winston, Roland; O'Gallagher, Joseph; Ford, Gary

    1984-01-01

    Two fixed, evacuated, glass solar thermal collectors have been designed. The incorporation of nonimaging concentration, selective absorption and vacuum insulation into their design is essential for obtaining high efficiency through low heat loss, while operating at high temperatures. Nonimaging, approximately ideal concentration with wide acceptance angle permits solar radiation collection without tracking the sun, and insures collection of much of the diffuse radiation. It also minimizes the area of the absorbing surface, thereby reducing the radiation heat loss. Functional integration, where different parts of these two collectors serve more than one function, is also important in achieving high efficiency, and it reduces cost.

  7. Predicting the Burden of Revision Knee Arthroplasty: Simulation of a 20-Year Horizon.

    PubMed

    Guerrero-Ludueña, Richard E; Comas, Mercè; Espallargues, Mireia; Coll, Moisès; Pons, Miquel; Sabatés, Santiago; Allepuz, Alejandro; Castells, Xavier

    2016-01-01

    To estimate future utilization scenarios for knee arthroplasty (KA) revision in the Spanish National Health System in the short- and long-term and their impact on primary KA utilization. A discrete-event simulation model was built to represent KA utilization for 20 years (2012-2031) in the Spanish National Health System. Data on KA utilization from 1997 to 2011 were obtained from the minimum data set. Three scenarios of future utilization of primary KA (1, fixed number since 2011; 2, fixed age- and sex-adjusted rates since 2011; and 3, projection using a linear regression model) were combined with two prosthesis survival functions (W [worse survival], from a study including primary KA from 1995 to 2000; and B [better survival], from the Catalan Registry of Arthroplasty, including primary KA from 2005 to 2013). The simulation results were analyzed in the short-term (2015) and the long-term (2030). Variations in the number of revisions depended on both the primary utilization rate and the survival function applied, ranging from increases of 8.3% to 31.6% in the short- term and from 38.3% to 176.9% in the long-term, corresponding to scenarios 1-B and 3-W, respectively. The prediction of increases in overall surgeries ranged from 0.1% to 22.3% in the short-term and from 3.7% to 98.2% in the long-term. Projections of the burden of KA provide a quantitative basis for future policy decisions on the concentration of high-complexity procedures, the number of orthopedic surgeons required to perform these procedures, and the resources needed. Copyright © 2016 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  8. A simple procedure for the extraction of DNA from long-term formalin-preserved brain tissues for the detection of EBV by PCR.

    PubMed

    Hassani, Asma; Khan, Gulfaraz

    2015-12-01

    Long-term formalin fixed brain tissues are potentially an important source of material for molecular studies. Ironically, very few protocols have been published describing DNA extraction from such material for use in PCR analysis. In our attempt to investigate the role of Epstein-Barr virus (EBV) in the pathogenesis of multiple sclerosis (MS), extracting PCR quality DNA from brain samples fixed in formalin for 2-22 years, proved to be very difficult and challenging. As expected, DNA extracted from these samples was not only of poor quality and quantity, but more importantly, it was frequently found to be non-amplifiable due to the presence of PCR inhibitors. Here, we describe a simple and reproducible procedure for extracting DNA using a modified proteinase K and phenol-chloroform methodology. Central to this protocol is the thorough pre-digestion washing of the tissues in PBS, extensive digestion with proteinase K in low SDS containing buffer, and using low NaCl concentration during DNA precipitation. The optimized protocol was used in extracting DNA from meninges of 26 MS and 6 non-MS cases. Although the quality of DNA from these samples was generally poor, small size amplicons (100-200 nucleotides) of the house-keeping gene, β-globin could be reliably amplified from all the cases. PCR for EBV revealed positivity in 35% (9/26) MS cases, but 0/6 non-MS cases. These findings indicate that the method described here is suitable for PCR detection of viral sequences in long-term formalin persevered brain tissues. Our findings also support a possible role for EBV in the pathogenesis of MS. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Influence of experimental history on nicotine self-administration in squirrel monkeys.

    PubMed

    Desai, Rajeev I; Sullivan, Katherine A; Kohut, Stephen J; Bergman, Jack

    2016-06-01

    Methods for establishing robust long-term self-administration of intravenous (i.v.) nicotine, the primary psychoactive agent in tobacco, are not well-established in laboratory animals. Here, we examine the use of a fading procedure to establish robust and consistent i.v. nicotine self-administration under second-order schedule conditions in squirrel monkeys. First, self-administration behavior was developed in two groups of male squirrel monkeys using a second-order fixed-interval 5-min schedule with fixed-ratio 5 units (FI 5-min (FR5: S)). Comparable performances were maintained by i.v. cocaine (0.032 mg/kg/injection (inj); group A, n = 3) and the combination of food delivery (20-30 % condensed milk) and 0.01 mg/kg/inj i.v. nicotine (group B, n = 3). Subsequently, the concentration of condensed milk was gradually reduced to zero in the second group and self-administration behavior was maintained by i.v. nicotine alone. Next, self-administration of a range of doses of i.v. nicotine (0.001-0.032 mg/kg/inj) and, in additional experiments, the minor tobacco alkaloid anatabine (0.01-0.18 mg/kg/inj) was studied in both groups. Results show that nicotine and anatabine had reinforcing effects in both groups. However, optimal doses of nicotine and anatabine maintained significantly higher rates of i.v. self-administration behavior in subjects trained with the fading procedure than in subjects provided with a history of cocaine-maintained responding. These results illustrate conditions under which robust i.v. nicotine self-administration can be established in squirrel monkeys and the influence of prior experimental history in the expression of reinforcing effects of nicotine and anatabine.

  10. Surface-water-quality assessment of the Kentucky River Basin, Kentucky; fixed-station network and selected water-quality data, April 1987 through August 1991

    USGS Publications Warehouse

    Griffin, M.S.; Martin, G.R.; White, K.D.

    1994-01-01

    This report describes selected data-collection activities and the associated data collected during the Kentucky River Basin pilot study of the U.S. Geological Survey's National Water-Quality Assessment Program. The data are intended to provide a nationally consistent description and improved understanding of current water quality in the basin. The data were collected at seven fixed stations that represent stream cross sections where constituent transport and water-quality trends can be evaluated. The report includes descriptions of (1) the basin; (2) the design of the fixed-station network; (3) the fixed-station sites; (4) the physical and chemical measurements; (5) the methods of sample collection, processing, and analysis; and (6) the quality-assurance and quality-control procedures. Water-quality data collected at the fixed stations during routine periodic sampling and supplemental high-flow sampling from April 1987 to August 1991 are presented.

  11. Mechanisms Underlying the Breast Cancer Susceptibility Locus Mcs5a

    DTIC Science & Technology

    2010-07-01

    fixed using formaldehyde . The extracted fixed chromatin is digested with a restriction enzyme and religated in a strongly dilute fashion. In this...procedure the ligation of genetic elements that were glued together by formaldehyde fixation is favored over ligation of random elements. Following... digested and randomly ligated control template containing all restriction fragments of interest in equal molarity. To investigate the Mcs5a1-Mcs5a2

  12. Tactical Infrasound

    DTIC Science & Technology

    2005-05-01

    received briefings on a variety of infra - sonic sensor systenis. Materials were also received from the 2001 and 2002 Infrasonic Technology Workshops and...Systems to Tactical Acoustic Sys- tems One issue to be considered in the evaluation of a p)otential tactical infra - sonic system is the ability to...Communication range Fixed Fixed 5 km 7.4 A Design Approach for a Future Tactical Infra - sonic Sensor System This section describes a procedure used to

  13. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 °C. Part 9: reference procedure for the measurement of catalytic concentration of alkaline phosphatase International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Scientific Division, Committee on Reference Systems of Enzymes (C-RSE) (1)).

    PubMed

    Schumann, Gerhard; Klauke, Rainer; Canalias, Francesca; Bossert-Reuther, Steffen; Franck, Paul F H; Gella, F-Javier; Jørgensen, Poul J; Kang, Dongchon; Lessinger, Jean-Marc; Panteghini, Mauro; Ceriotti, Ferruccio

    2011-09-01

    Abstract This paper is the ninth in a series dealing with reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 °C and the certification of reference preparations. Other parts deal with: Part 1. The concept of reference procedures for the measurement of catalytic activity concentrations of enzymes; Part 2. Reference procedure for the measurement of catalytic concentration of creatine kinase; Part 3. Reference procedure for the measurement of catalytic concentration of lactate dehydrogenase; Part 4. Reference procedure for the measurement of catalytic concentration of alanine aminotransferase; Part 5. Reference procedure for the measurement of catalytic concentration of aspartate aminotransferase; Part 6. Reference procedure for the measurement of catalytic concentration of γ-glutamyltransferase; Part 7. Certification of four reference materials for the determination of enzymatic activity of γ-glutamyltransferase, lactate dehydrogenase, alanine aminotransferase and creatine kinase at 37 °C; Part 8. Reference procedure for the measurement of catalytic concentration of α-amylase. The procedure described here is derived from the previously described 30 °C IFCC reference method. Differences are tabulated and commented on in Appendix 1.

  14. Training Challenges for the U.S. Army in the Pacific

    DTIC Science & Technology

    2013-03-01

    each other on a frequent enough basis to be thought of as “interoperable.” All the parties involved have different standard operating procedures ...13 All have different command and control technologies and all have different procedures to plan, prepare, coordinate and synchronize operations...does not fix it. Joint Task Force tactics, techniques and procedures are eventually developed but they take time and amount to a band aid as opposed

  15. Kinetic Spectrophotometric Determination of Biotin in Pharmaceutical Preparations

    PubMed Central

    Walash, M. I.; Rizk, M.; Sheribah, Z. A.; Salim, M. M.

    2008-01-01

    A simple accurate kinetic spectrophotometric method was developed for the determination of biotin in pure form and pharmaceutical preparations. The proposed method is based on a catalytic acceleration of biotin on the reaction between sodium azide and tri-iodide in an aqueous solution. Concentration range of 4-16 μg/mL for biotin was determined by measuring the decrease in the absorbance of tri-iodide at 348 nm by a fixed time method. The decrease in absorbance after 14 min from the initiation of the reaction was markedly correlated to the concentration with correlation coefficient of 0.9999. The detection limit (LOD) of biotin was 0.18 μg/mL while quantitation limit (LOQ) was 0.54 μg/mL. The percentage recovery of the spiked samples was 100.08 ± 0.761. The proposed procedure was successfully applied for the determination of biotin in its pharmaceutical preparations with mean recoveries of 101.17 ± 2.05 and 97.87 ± 1.50 for biotin ampoules and capsules, respectively. The results obtained were in good agreement with those obtained using official method. PMID:23675096

  16. Autoradiographic demonstration of oxytocin-binding sites in the macula densa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stoeckel, M.E.; Freund-Mercier, M.J.

    1989-08-01

    Specific oxytocin (OT)-binding sites were localized in the rat kidney with use of a selective {sup 125}I-labeled OT antagonist ({sup 125}I-OTA). High concentrations of OT binding sites were detected on the juxtaglomerular apparatus with use of the conventional film autoradiographic technique. No labeling occurred on other renal structures. The cellular localization of the OT binding sites within the juxtaglomerular apparatus was studied in light microscope autoradiography, on semithin sections from paraformaldehyde-fixed kidney slices incubated in the presence of {sup 125}I-OTA. These preparations revealed selective labeling of the macula densa, mainly concentrated at the basal pole of the cells. Control experimentsmore » showed first that {sup 125}I-OTA binding characteristics were not noticeably altered by prior paraformaldehyde fixation of the kidneys and second that autoradiographic detection of the binding sites was not impaired by histological treatments following binding procedures. In view of the role of the macula densa in the tubuloglomerular feedback, the putative OT receptors of this structure might mediate the stimulatory effect of OT on glomerular filtration.« less

  17. A CFD-based aerodynamic design procedure for hypersonic wind-tunnel nozzles

    NASA Technical Reports Server (NTRS)

    Korte, John J.

    1993-01-01

    A new procedure which unifies the best of current classical design practices, computational fluid dynamics (CFD), and optimization procedures is demonstrated for designing the aerodynamic lines of hypersonic wind-tunnel nozzles. The new procedure can be used to design hypersonic wind tunnel nozzles with thick boundary layers where the classical design procedure has been shown to break down. An efficient CFD code, which solves the parabolized Navier-Stokes (PNS) equations using an explicit upwind algorithm, is coupled to a least-squares (LS) optimization procedure. A LS problem is formulated to minimize the difference between the computed flow field and the objective function, consisting of the centerline Mach number distribution and the exit Mach number and flow angle profiles. The aerodynamic lines of the nozzle are defined using a cubic spline, the slopes of which are optimized with the design procedure. The advantages of the new procedure are that it allows full use of powerful CFD codes in the design process, solves an optimization problem to determine the new contour, can be used to design new nozzles or improve sections of existing nozzles, and automatically compensates the nozzle contour for viscous effects as part of the unified design procedure. The new procedure is demonstrated by designing two Mach 15, a Mach 12, and a Mach 18 helium nozzles. The flexibility of the procedure is demonstrated by designing the two Mach 15 nozzles using different constraints, the first nozzle for a fixed length and exit diameter and the second nozzle for a fixed length and throat diameter. The computed flow field for the Mach 15 least squares parabolized Navier-Stokes (LS/PNS) designed nozzle is compared with the classically designed nozzle and demonstrates a significant improvement in the flow expansion process and uniform core region.

  18. Liquidus slopes of impurities in ITS-90 fixed points from the mercury point to the copper point in the low concentration limit

    NASA Astrophysics Data System (ADS)

    Pearce, Jonathan V.; Gisby, John A.; Steur, Peter P. M.

    2016-08-01

    A knowledge of the effect of impurities at the level of parts per million on the freezing temperature of very pure metals is essential for realisation of ITS-90 fixed points. New information has become available for use with the thermodynamic modelling software MTDATA, permitting calculation of liquidus slopes, in the low concentration limit, of a wider range of binary alloy systems than was previously possible. In total, calculated values for 536 binary systems are given. In addition, new experimental determinations of phase diagrams, in the low impurity concentration limit, have recently appeared. All available data have been combined to provide a comprehensive set of liquidus slopes for impurities in ITS-90 metal fixed points. In total, liquidus slopes for 838 systems are tabulated for the fixed points Hg, Ga, In, Sn, Zn, Al, Ag, Au, and Cu. It is shown that the value of the liquidus slope as a function of impurity element atomic number can be approximated using a simple formula, and good qualitative agreement with the existing data is observed for the fixed points Al, Ag, Au and Cu, but curiously the formula is not applicable to the fixed points Hg, Ga, In, Sn, and Zn. Some discussion is made concerning the influence of oxygen on the liquidus slopes, and some calculations using MTDATA are discussed. The BIPM’s consultative committee for thermometry has long recognised that the sum of individual estimates method is the ideal approach for assessing uncertainties due to impurities, but the community has been largely powerless to use the model due to lack of data. Here, not only is data provided, but a simple model is given to enable known thermophysical data to be used directly to estimate impurity effects for a large fraction of the ITS-90 fixed points.

  19. Treatment of hemophilia B: focus on recombinant factor IX

    PubMed Central

    Franchini, Massimo; Frattini, Francesco; Crestani, Silvia; Sissa, Cinzia; Bonfanti, Carlo

    2013-01-01

    Hemophilia B is a recessive X-linked bleeding disorder characterized by deficiency of the coagulation factor IX (FIX). In hemophilia B patients the severity of the bleeding phenotype is related to the degree of the FIX defect. Hemophilia B treatment has improved greatly in the last 20 years with the introduction first of plasma-derived and then of recombinant FIX concentrates. Replacement therapy may be administered through on-demand or prophylaxis regimens, but the latter treatment modality has been shown to be superior in prevention of hemophilic arthropathy and in improvement of patients’ quality of life. The purpose of this narrative review is to summarize the current knowledge on treatment strategies for hemophilia B, focusing on recombinant FIX products either clinically used or in development. There is only one rFIX product that is licensed to treat hemophilia B patients; from the analysis of the literature data presented in this review, the authors conclude that this rFIX product has demonstrated an excellent safety profile and excellent clinical efficacy for halting and preventing bleeds in hemophilia B patients. While prophylaxis has emerged as the best therapeutic strategy for such patients because of its ability to prevent hemophilic arthropathy and to improve patients’ quality of life, the pharmacokinetically tailored dosing of rFIX is another key point when planning hemophilia B treatment, as it allows optimization of the factor concentrate usage. Further clinical studies are needed to better assess the safety and efficacy (ie, the incidence of adverse reactions and inhibitor development) of newer rFIX products. PMID:23430394

  20. Costing imaging procedures.

    PubMed

    Bretland, P M

    1988-01-01

    The existing National Health Service financial system makes comprehensive costing of any service very difficult. A method of costing using modern commercial methods has been devised, classifying costs into variable, semi-variable and fixed and using the principle of overhead absorption for expenditure not readily allocated to individual procedures. It proved possible to establish a cost spectrum over the financial year 1984-85. The cheapest examinations were plain radiographs outside normal working hours, followed by plain radiographs, ultrasound, special procedures, fluoroscopy, nuclear medicine, angiography and angiographic interventional procedures in normal working hours. This differs from some published figures, particularly those in the Körner report. There was some overlap between fluoroscopic interventional and the cheaper nuclear medicine procedures, and between some of the more expensive nuclear medicine procedures and the cheaper angiographic ones. Only angiographic and the few more expensive nuclear medicine procedures exceed the cost of the inpatient day. The total cost of the imaging service to the district was about 4% of total hospital expenditure. It is shown that where more procedures are undertaken, the semi-variable and fixed (including capital) elements of the cost decrease (and vice versa) so that careful study is required to assess the value of proposed economies. The method is initially time-consuming and requires a computer system with 512 Kb of memory, but once the basic costing system is established in a department, detailed financial monitoring should become practicable. The necessity for a standard comprehensive costing procedure of this nature, based on sound cost accounting principles, appears inescapable, particularly in view of its potential application to management budgeting.

  1. Fixed-bed adsorption of reactive azo dye onto granular activated carbon prepared from waste.

    PubMed

    Ahmad, A A; Hameed, B H

    2010-03-15

    In this work, the adsorption potential of bamboo waste based granular activated carbon (BGAC) to remove C.I. Reactive Black (RB5) from aqueous solution was investigated using fixed-bed adsorption column. The effects of inlet RB5 concentration (50-200mg/L), feed flow rate (10-30 mL/min) and activated carbon bed height (40-80 mm) on the breakthrough characteristics of the adsorption system were determined. The highest bed capacity of 39.02 mg/g was obtained using 100mg/L inlet dye concentration, 80 mm bed height and 10 mL/min flow rate. The adsorption data were fitted to three well-established fixed-bed adsorption models namely, Adam's-Bohart, Thomas and Yoon-Nelson models. The results fitted well to the Thomas and Yoon-Nelson models with coefficients of correlation R(2)>or=0.93 at different conditions. The BGAC was shown to be suitable adsorbent for adsorption of RB5 using fixed-bed adsorption column. (c) 2009 Elsevier B.V. All rights reserved.

  2. Considering interactive effects in the identification of influential regions with extremely rare variants via fixed bin approach

    PubMed Central

    2014-01-01

    In this study, we analyze the Genetic Analysis Workshop 18 (GAW18) data to identify regions of single-nucleotide polymorphisms (SNPs), which significantly influence hypertension status among individuals. We have studied the marginal impact of these regions on disease status in the past, but we extend the method to deal with environmental factors present in data collected over several exam periods. We consider the respective interactions between such traits as smoking status and age with the genetic information and hope to augment those genetic regions deemed influential marginally with those that contribute via an interactive effect. In particular, we focus only on rare variants and apply a procedure to combine signal among rare variants in a number of "fixed bins" along the chromosome. We extend the procedure in Agne et al [1] to incorporate environmental factors by dichotomizing subjects via traits such as smoking status and age, running the marginal procedure among each respective category (i.e., smokers or nonsmokers), and then combining their scores into a score for interaction. To avoid overlap of subjects, we examine each exam period individually. Out of a possible 629 fixed-bin regions in chromosome 3, we observe that 11 show up in multiple exam periods for gene-smoking score. Fifteen regions exhibit significance for multiple exam periods for gene-age score, with 4 regions deemed significant for all 3 exam periods. The procedure pinpoints SNPs in 8 "answer" genes, with 5 of these showing up as significant in multiple testing schemes (Gene-Smoking, Gene-Age for Exams 1, 2, and 3). PMID:25519400

  3. Modeling hexavalent chromium removal in a Bacillus sp. fixed-film bioreactor.

    PubMed

    Nkhalambayausi-Chirwa, Evans M; Wang, Yi-Tin

    2004-09-30

    A one-dimensional diffusion-reaction model was developed to simulate Cr(VI) reduction in a Bacillus sp. pure culture biofilm reactor with glucose as a sole supplied carbon and energy source. Substrate utilization and Cr(VI) reduction in the biofilm was best represented by a system of (second-order) partial differential equations (PDEs). The PDE system was solved by the (fourth-order) Runge-Kutta method adjusted for mass transport resistance using the (second-order) Crank-Nicholson and Backward Euler finite difference methods. A heuristic procedure (genetic search algorithm) was used to find global optimum values of Cr(VI) reduction and substrate utilization rate kinetic parameters. The fixed-film bioreactor system yielded higher values of the maximum specific Cr(VI) reduction rate coefficient and Cr(VI) reduction capacity (kmc = 0.062 1/h, and Rc = 0.13 mg/mg, respectively) than previously determined in batch reactors (kmc = 0.022 1/h and Rc = 0.012 mg/mg). The model predicted effluent Cr(VI) concentration well with 98.9% confidence (sigmay2 = 2.37 mg2/L2, N = 119) and effluent glucose with 96.4 % confidence (sigmay(w)2 = 5402 mg2/L2, N = 121, w = 100) over a wide range of Cr(VI) loadings (10-498 mg Cr(VI)/L/d). Copyright 2004 Wiley Periodicals, Inc.

  4. 78 FR 56256 - Self-Regulatory Organizations; NYSE Arca, Inc.; Order Granting Approval of Proposed Rule Change...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-12

    ... portfolio, and will be subject to procedures designed to prevent the use and dissemination of material non... Committee has implemented procedures designed to prevent the use and dissemination of material, non-public... employees of the Adviser) to be of equivalent quality.\\7\\ The Bond Portfolio will invest in fixed and...

  5. Confidence intervals from single observations in forest research

    Treesearch

    Harry T. Valentine; George M. Furnival; Timothy G. Gregoire

    1991-01-01

    A procedure for constructing confidence intervals and testing hypothese from a single trial or observation is reviewed. The procedure requires a prior, fixed estimate or guess of the outcome of an experiment or sampling. Two examples of applications are described: a confidence interval is constructed for the expected outcome of a systematic sampling of a forested tract...

  6. Evaluation of the Ca/P concentration ratio in hydroxyapatite by STEM-EDXS: influence of the electron irradiation dose and temperature processing

    NASA Astrophysics Data System (ADS)

    Benhayoune, H.; Charlier, D.; Jallot, E.; Laquerriere, P.; Balossier, G.; Bonhomme, P.

    2001-01-01

    Biomaterials used in dental and orthopaedic surgery to fill bony loss and to coat prostheses are either of natural or synthetic origin. Amongst these biomaterials, hydroxyapatites (HA) offer good properties of biocompatibility and bioactivity when they interact with bone. This interaction depends mainly on the physico-chemical properties of HA particles. In this work, using a scanning transmission electronic microscope equipped with an Si(Li) detector for x-ray analysis, we analysed three kinds of hydroxyapatite: non-sintered particles, 600 °C sintered particles and 1180 °C sintered particles. Then, we determined the Ca/P concentration ratio in order to observe the influence of the temperature processing on this ratio. Concurrently, we carried out measurements on the HA powders by varying the electron irradiation dose either with the current density or with irradiation time. When the electron irradiation dose varied with the current density (at constant and short irradiation time), the Ca/P concentration ratio did not vary. But, at fixed current density and increasing irradiation time, the calcium and phosphorus intensities decreased, leading to an increase of the Ca/P concentration ratio at high electron irradiation dose. This phenomenon represents a mass loss of the specimen during electronic bombardment. We propose an experimental procedure to avoid all these problems.

  7. A combined application of thermal desorber and gas chromatography to the analysis of gaseous carbonyls with the aid of two internal standards.

    PubMed

    Kim, Ki-Hyun; Anthwal, A; Pandey, Sudhir Kumar; Kabir, Ehsanul; Sohn, Jong Ryeul

    2010-11-01

    In this study, a series of GC calibration experiments were conducted to examine the feasibility of the thermal desorption approach for the quantification of five carbonyl compounds (acetaldehyde, propionaldehyde, butyraldehyde, isovaleraldehyde, and valeraldehyde) in conjunction with two internal standard compounds. The gaseous working standards of carbonyls were calibrated with the aid of thermal desorption as a function of standard concentration and of loading volume. The detection properties were then compared against two types of external calibration data sets derived by fixed standard volume and fixed standard concentration approach. According to this comparison, the fixed standard volume-based calibration of carbonyls should be more sensitive and reliable than its fixed standard concentration counterpart. Moreover, the use of internal standard can improve the analytical reliability of aromatics and some carbonyls to a considerable extent. Our preliminary test on real samples, however, indicates that the performance of internal calibration, when tested using samples of varying dilution ranges, can be moderately different from that derivable from standard gases. It thus suggests that the reliability of calibration approaches should be examined carefully with the considerations on the interactive relationships between the compound-specific properties and the operation conditions of the instrumental setups.

  8. Free-zone electrophoresis of animal cells. 1: Experiments on cell-cell interactions

    NASA Technical Reports Server (NTRS)

    Todd, P. W.; Hjerten, S.

    1985-01-01

    The electrophoretically migrating zones wasa monitored. The absence of fluid flows in the direction of migration permits direct measurement of electrophoretic velocities of any material. Sedimentation is orthogonal to electrokinetic motion and the effects of particle-particle interaction on electrophoretic mobility is studied by free zone electrophoresis. Fixed erythrocytes at high concentrations, mixtures of fixed erythrocytes from different animal species, and mixtures of cultured human cells were studied in low ionic strength buffers. The electrophoretic velocity of fixed erythrocytes was not altered by increasing cell concentration or by the mixing of erythrocytes from different species. When zones containing cultured human glial cells and neuroblastoma cells are permitted to interact during electrophoresis, altered migration patterns occur. It is found that cell-cell interactions depends upon cell type.

  9. Management of long span partially edentulous maxilla with fixed removable denture prosthesis

    PubMed Central

    Jeyavalan, Mahilan I.; Narasimman, M.; Venkatakrishnan, C. J.; Philip, Jacob M.

    2012-01-01

    Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis. PMID:23293488

  10. Management of long span partially edentulous maxilla with fixed removable denture prosthesis.

    PubMed

    Jeyavalan, Mahilan I; Narasimman, M; Venkatakrishnan, C J; Philip, Jacob M

    2012-07-01

    Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis.

  11. [Distribution of organic carbon and carbon fixed strength of phytoplankton in Enteromorpha prolifera outbreak area of the Western South Yellow Sea, 2008].

    PubMed

    Xia, Bin; Ma, Shao-Sai; Chen, Ju-Fa; Zhao, Jun; Chen, Bi-Juan; Wang, Fang

    2010-06-01

    Based on the analysis of dissolved organic carbon (DOC), particulate organic carbon (POC) and particulate nitrogen (PN) of the samples collected from stations in Enteromorpha prolifera outbreak area of the Western South Yellow Sea during the period August 9-13 of 2008, combining with the data of environmental hydrology, the horizontal distribution, source and influential factors of organic carbon and carbon fixed strength of phytoplankton were discussed. The results showed that the concentrations of DOC and POC ranged from 1.55 mg/L to 3.22 mg/L, 0.11 mg/L to 0.68 mg/L, with average values of 2.44 mg/L and 0.27 mg/L. The horizontal distributions of DOC and POC were similar in study area. The concentrations of DOC and POC in coastal area were higher than that in the outer sea and the concentrations of DOC and POC at surface water layer were higher than those at the bottom water layer. There were a positive correlation between POC and TSS, indicating that the concentrations and source of TSS were main factors for the POC. According to the univariate linear regression model between POC and PN, the concentrations of particulate inorganic nitrogen (PIN) were evaluated. Removing the content of PIN in the samples, the average POC/PON values in most coastal waters were less than 8, combining with the values of POC/chlorophyll a, suggesting that the marine primary production were the important source of POC in most coastal waters, and the presence of degraded organic matter which derived from degraded Enteromorph prolifera was in the latter period of green tide outbreak. The results of evaluated carbon fixed strength based on primary productivity showed that carbon fixed strength of phytoplankton in Enteromorpha prolifera outbreak area of the Western South Yellow Sea ranged from 167 mg/(m2 x d) to 2017 mg/(m2 x d), with the average of 730 mg/(m2 x d). The daily carbon fixed quantities of the study area were up to 2.95 x 10(4) t. Then the daily carbon fixed quantities of the Yellow Sea were 28.03 x 10(4) t.

  12. A systematic approach to the control of esthetic form.

    PubMed

    Preston, J D

    1976-04-01

    A systematic, orderly approach to the problem of establishing harmonious phonetics, esthetics, and function in fixed restorations has been described. The system requires an initial investment of time in performing an adequate diagnostic waxing, but recoups that time in many clinical and laboratory procedures. The method has proved a valuable asset in fixed prosthodontic care. The technique can be expanded and combined with other techniques with a little imagination and artistic bent.

  13. Toward Wisdom in Procedural Reasoning: DBI, not BDI

    DTIC Science & Technology

    2003-10-04

    a our current, ever-expanding understanding of the human procedural reasoning system to one that chooses procedures mind as embodied in the brain and...the rest of the body . The wisely, a logical circularity becomes apparent, as the explicit premise of this re-ordering is that a sapient DBI structure...from Searle that pro- implementation. As an advance over this fixed realism, a attitudes such as desires and wishes have a "world-to- mind " new

  14. Total cost comparison of 2 biopsy methods for nonpalpable breast lesions.

    PubMed

    Bodai, B I; Boyd, B; Brown, L; Wadley, H; Zannis, V J; Holzman, M

    2001-05-01

    To identify, quantify, and compare total facility costs for 2 breast biopsy methods: vacuum-assisted biopsy (VAB) and needle-wire-localized open surgical biopsy (OSB). A time-and-motion study was done to identify unit resources used in both procedures. Costs were imputed from published literature to value resources. A comparison of the total (fixed and variable) costs of the 2 procedures was done. A convenience sample of 2 high-volume breast biopsy (both VAB and OSB) facilities was identified. A third facility (OSB only) and 8 other sites (VAB only) were used to capture variation. Staff interviews, patient medical records, and billing data were used to check observed data. One hundred and sixty-seven uncomplicated procedures (71 OSBs, 96 VABs) were observed. Available demographic and clinical data were analyzed to assess selection bias, and sensitivity analyses were done on the main assumptions. The total facility costs of the VAB procedure were lower than the costs of the OSB procedure. The overall cost advantage for using VAB ranges from $314 to $843 per procedure depending on the facility type. Variable cost comparison indicated little difference between the 2 procedures. The largest fixed cost difference was $763. Facilities must consider the cost of new technology, especially when the new technology is as effective as the present technology. The seemingly high cost of equipment might negatively influence a decision to adopt VAB, but when total facility costs were analyzed, the new technology was less costly.

  15. REGULATORY MECHANISMS OF CELLULAR RESPIRATION

    PubMed Central

    Barron, E. S. Guzman; Nelson, Leonard; Ardao, Maria Isabel

    1948-01-01

    Oxidizing agents of sulfhydryl groups such as iodosobenzoate, alkylating agents such as iodoacetamide, and mercaptide-forming agents such as cadmium chloride, mercuric chloride, p-chloromercuribenzoate, sodium arsenite, and p-carboxyphenylarsine oxide, added in small concentrations to a suspension of sea urchin sperm produced an increase in respiration. When the concentration was increased there was an inhibition. These effects are explained by postulating the presence in the cells of two kinds of sulfhydryl groups: soluble sulfhydryl groups, which regulate cellular respiration, and fixed sulfhydryl groups, present in the protein moiety of enzymes. Small concentrations of sulfhydryl reagents combine only with the first, thus producing an increase in respiration; when the concentration is increased, the fixed sulfhydryl groups are also attacked and inhibition of respiration is the consequence. Other inhibitors of cell respiration, such as cyanide and urethanes, which do not combine with —SH groups, did not stimulate respiration in small concentration. PMID:18891144

  16. Fluorine-fixing efficiency on calcium-based briquette: pilot experiment, demonstration and promotion.

    PubMed

    Yang, Jiao-lan; Chen, Dong-qing; Li, Shu-min; Yue, Yin-ling; Jin, Xin; Zhao, Bing-cheng; Ying, Bo

    2010-02-05

    The fluorosis derived from coal burning is a very serious problem in China. By using fluorine-fixing technology during coal burning we are able to reduce the release of fluorides in coal at the source in order to reduce pollution to the surrounding environment by coal burning pollutants as well as decrease the intake and accumulating amounts of fluorine in the human body. The aim of this study was to conduct a pilot experiment on calcium-based fluorine-fixing material efficiency during coal burning to demonstrate and promote the technology based on laboratory research. A proper amount of calcium-based fluorine sorbent was added into high-fluorine coal to form briquettes so that the fluorine in high-fluorine coal can be fixed in coal slag and its release into atmosphere reduced. We determined figures on various components in briquettes and fluorine in coal slag as well as the concentrations of indoor air pollutants, including fluoride, sulfur dioxide and respirable particulate matter (RPM), and evaluated the fluorine-fixing efficiency of calcium-based fluorine sorbents and the levels of indoor air pollutants. Pilot experiments on fluorine-fixing efficiency during coal burning as well as its demonstration and promotion were carried out separately in Guiding and Longli Counties of Guizhou Province, two areas with coal burning fluorosis problems. If the calcium-based fluorine sorbent mixed coal was made into honeycomb briquettes the average fluorine-fixing ratio in the pilot experiment was 71.8%. If the burning calcium-based fluorine-fixing bitumite was made into a coalball, the average of fluorine-fixing ratio was 77.3%. The concentration of fluoride, sulfur dioxide and PM10 of indoor air were decreased significantly. There was a 10% increase in the cost of briquettes due to the addition of calcium-based fluorine sorbent. The preparation process of calcium-based fluorine-fixing briquette is simple yet highly flammable and it is applicable to regions with abundant bitumite coal. As a small scale application, villagers may make fluorine-fixing coalballs or briquettes by themselves, achieving the optimum fluorine-fixing efficiency and reducing indoor air pollutants providing environmental and social benefits.

  17. Identification and quantification of ciprofloxacin in urine through excitation-emission fluorescence and three-way PARAFAC calibration.

    PubMed

    Ortiz, M C; Sarabia, L A; Sánchez, M S; Giménez, D

    2009-05-29

    Due to the second-order advantage, calibration models based on parallel factor analysis (PARAFAC) decomposition of three-way data are becoming important in routine analysis. This work studies the possibility of fitting PARAFAC models with excitation-emission fluorescence data for the determination of ciprofloxacin in human urine. The finally chosen PARAFAC decomposition is built with calibration samples spiked with ciprofloxacin, and with other series of urine samples that were also spiked. One of the series of samples has also another drug because the patient was taking mesalazine. The mesalazine is a fluorescent substance that interferes with the ciprofloxacin. Finally, the procedure is applied to samples of a patient who was being treated with ciprofloxacin. The trueness has been established by the regression "predicted concentration versus added concentration". The recovery factor is 88.3% for ciprofloxacin in urine, and the mean of the absolute value of the relative errors is 4.2% for 46 test samples. The multivariate sensitivity of the fit calibration model is evaluated by a regression between the loadings of PARAFAC linked to ciprofloxacin versus the true concentration in spiked samples. The multivariate capability of discrimination is near 8 microg L(-1) when the probabilities of false non-compliance and false compliance are fixed at 5%.

  18. [Effect of phosphate and organic acid addition on passivation of simulated Pb contaminated soil and the stability of the product].

    PubMed

    Zuo, Ji-Chao; Gao, Ting-Ting; Su, Xiao-Juan; Wan, Tian-Ying; Hu, Hong-Qing

    2014-10-01

    Organic acids can improve the phosphorus availability, influence the immobilization of heavy metals in soil, and has very complicated function in phosphorus activation and heavy metal passivation. This research took simulated Pb contaminated soil as material, phosphate and citric acid as remediation matter, adopted BCR continuous extraction, 0.01 mol · L(-1) CaCl2 and toxicity characteristic leaching procedure (TCLP) to evaluate the remediation effect. Besides, malic acid and NaNO3 were taken as desorption reagents to discuss the stability of the phosphorus-citric acid-Pb system. The results showed that: in the absence of citric acid, the amount of acid extracted Pb decreased along with the increase of P concentration; when the P concentration was 100 and 400 mg · kg(-1), acid extractable Pb increased with the increasing of citric acid concentration. However, residual Pb changed in the opposite direction from acid extractable Pb. The phenomenon showed that P improved the bioavailability of Pb, while citric acid had the opposite effect. With a certain organic acid concentration, extractable Pb contents extracted by 0.01 mol · L(-1) CaCl2 and TCLP both decreased with the increasing P concentration, therefore, P had immobilization effect on Pb in contaminated soil. But at a fixed P concentration, extractable Pb contents by 0.01 mol · L(-1) CaCl2 and TCLP changed in the opposite trend with the increasing citric acid concentration. The desorption rate of Pb in soil increased with the increasing malic acid concentration, the decreasing pH and the increasing ionic strength. The desorption extent of Pb in soil with P only was lower than that with both P and citric acid. But the stability of Pb passivated by the former was higher.

  19. Microscopic Procedures for Plant Meiosis.

    ERIC Educational Resources Information Center

    Braselton, James P.

    1997-01-01

    Describes laboratory techniques designed to familiarize students with meiosis and how microscopic preparations of meiosis are made. These techniques require the use of fresh or fixed flowers. Contains 18 references. (DDR)

  20. APPARATUS FOR SHORT TIME MEASUREMENTS IN A FIXED-BED, GAS/SOLID REACTOR

    EPA Science Inventory

    An apparatus for exposure of a solid to reactive process gas is described which makes possible short time (≥ 0.3 to 15 s) exposures in a fixed-bed reactor. Operating conditions for differential reaction with respect to the gas concentration and rapid quench for arresting hi...

  1. Canadian Health Measures Survey pre-test: design, methods, results.

    PubMed

    Tremblay, Mark; Langlois, Renée; Bryan, Shirley; Esliger, Dale; Patterson, Julienne

    2007-01-01

    The Canadian Health Measures Survey (CHMS) pre-test was conducted to provide information about the challenges and costs associated with administering a physical health measures survey in Canada. To achieve the specific objectives of the pre-test, protocols were developed and tested, and methods for household interviewing and clinic testing were designed and revised. The cost, logistics and suitability of using fixed sites for the CHMS were assessed. Although data collection, transfer and storage procedures are complex, the pre-test experience confirmed Statistics Canada's ability to conduct a direct health measures survey and the willingness of Canadians to participate in such a health survey. Many operational and logistical procedures worked well and, with minor modifications, are being employed in the main survey. Fixed sites were problematic, and survey costs were higher than expected.

  2. Renormalization group procedure for potential -g/r2

    NASA Astrophysics Data System (ADS)

    Dawid, S. M.; Gonsior, R.; Kwapisz, J.; Serafin, K.; Tobolski, M.; Głazek, S. D.

    2018-02-01

    Schrödinger equation with potential - g /r2 exhibits a limit cycle, described in the literature in a broad range of contexts using various regularizations of the singularity at r = 0. Instead, we use the renormalization group transformation based on Gaussian elimination, from the Hamiltonian eigenvalue problem, of high momentum modes above a finite, floating cutoff scale. The procedure identifies a richer structure than the one we found in the literature. Namely, it directly yields an equation that determines the renormalized Hamiltonians as functions of the floating cutoff: solutions to this equation exhibit, in addition to the limit-cycle, also the asymptotic-freedom, triviality, and fixed-point behaviors, the latter in vicinity of infinitely many separate pairs of fixed points in different partial waves for different values of g.

  3. Advancements in the application of NanoSIMS and Raman microspectroscopy to investigate the activity of microbial cells in soils

    DOE PAGES

    Eichorst, Stephanie A.; Strasser, Florian; Woyke, Tanja; ...

    2015-08-31

    The combined approach of incubating environmental samples with stable isotope-labeled substrates followed by single-cell analyses through high-resolution secondary ion mass spectrometry (NanoSIMS) or Raman microspectroscopy provides insights into the in situ function of microorganisms. This approach has found limited application in soils presumably due to the dispersal of microbial cells in a large background of particles. We developed a pipeline for the efficient preparation of cell extracts from soils for subsequent single-cell methods by combining cell detachment with separation of cells and soil particles followed by cell concentration. The procedure was evaluated by examining its influence on cell recoveries andmore » microbial community composition across two soils. This approach generated a cell fraction with considerably reduced soil particle load and of sufficient small size to allow single-cell analysis by NanoSIMS, as shown when detecting active N2-fixing and cellulose-responsive microorganisms via 15N2 and 13C-UL-cellulose incubations, respectively. The same procedure was also applicable for Raman microspectroscopic analyses of soil microorganisms, assessed via microcosm incubations with a 13C-labeled carbon source and deuterium oxide (D2O, a general activity marker). Lastly, the described sample preparation procedure enables single-cell analysis of soil microorganisms using NanoSIMS and Raman microspectroscopy, but should also facilitate single-cell sorting and sequencing.« less

  4. Sex differences in the behavioral sequelae of chronic ethanol exposure.

    PubMed

    Jury, Nicholas J; DiBerto, Jeffrey F; Kash, Thomas L; Holmes, Andrew

    2017-02-01

    Rates of alcohol use disorders (AUDs) differ between men and women, and there is also marked variation between sexes in the effects of acute and chronic alcohol. In parallel to observations in humans, prior studies in rodents have described male/female differences across a range of ethanol-related behaviors, including ethanol drinking. Nonetheless, there remain gaps in our knowledge of the role of sex in moderating the effects of ethanol, particularly in models of chronic ethanol exposure. The goal of the current study was to assess various behavioral sequelae of exposing female C57BL/6J mice to chronic intermittent ethanol (CIE) via ethanol vapors. Following four weeks of CIE exposure, adult male and female mice were compared for ethanol drinking in a two-bottle paradigm, for sensitivity to acute ethanol intoxication (via loss of righting reflex [LORR]) and for anxiety-like behaviors in the novelty-suppressed feeding and marble burying assays. Next, adult and adolescent females were tested on two different two-bottle drinking preparations (fixed or escalating ethanol concentration) after CIE. Results showed that males and females exhibited significantly blunted ethanol-induced LORR following CIE, whereas only males showed increased anxiety-like behavior after CIE. Increased ethanol drinking after CIE was also specific to males, but high baseline drinking in females may have occluded detection of a CIE-induced effect. The failure to observe elevated drinking in females in response to CIE was also seen in females exposed to CIE during adolescence, regardless of whether a fixed or escalating ethanol-concentration two-bottle procedure was employed. Collectively, these data add to the literature on sex differences in ethanol-related behaviors and provide a foundation for future studies examining how the neural consequences of CIE might differ between males and females. Published by Elsevier Inc.

  5. Sex differences in the behavioral sequelae of chronic ethanol exposure

    PubMed Central

    Jury, Nicholas J.; DiBerto, Jeffrey F.; Kash, Thomas L.; Holmes, Andrew

    2016-01-01

    Rates of alcohol use disorders (AUDs) differ between men and women, and there is also marked variation between sexes in the effects of acute and chronic alcohol. In parallel to observations in humans, prior studies in rodents have described male/female differences across a range of ethanol-related behaviors, including ethanol drinking. Nonetheless, there remain gaps in our knowledge of the role of sex in moderating the effects of ethanol, particularly in models of chronic ethanol exposure. The goal of the current study was to assess various behavioral sequelae of exposing female C57BL/6J mice to chronic intermittent ethanol (CIE) via ethanol vapors. Following four weeks of CIE exposure, adult male and female mice were compared for ethanol drinking in a two-bottle paradigm, for sensitivity to acute ethanol intoxication (via loss of righting reflex [LORR]) and for anxiety-like behaviors in the novelty-suppressed feeding and marble burying assays. Next, adult and adolescent females were tested on two different two-bottle drinking preparations (fixed or escalating ethanol concentration) after CIE. Results showed that males and females exhibited significantly blunted ethanol-induced LORR following CIE, whereas only males showed increased anxiety-like behavior after CIE. Increased ethanol drinking after CIE was also specific to males, but high baseline drinking in females may have occluded detection of a CIE-induced effect. The failure to observe elevated drinking in females in response to CIE was also seen in females exposed to CIE during adolescence, regardless of whether a fixed or escalating ethanol-concentration two-bottle procedure was employed. Collectively, these data add to the literature on sex differences in ethanol-related behaviors and provide a foundation for future studies examining how the neural consequences of CIE might differ between males and females. PMID:27624846

  6. Determinants of wood dust exposure in the Danish furniture industry.

    PubMed

    Mikkelsen, Anders B; Schlunssen, Vivi; Sigsgaard, Torben; Schaumburg, Inger

    2002-11-01

    This paper investigates the relation between wood dust exposure in the furniture industry and occupational hygiene variables. During the winter 1997-98 54 factories were visited and 2362 personal, passive inhalable dust samples were obtained; the geometric mean was 0.95 mg/m(3) and the geometric standard deviation was 2.08. In a first measuring round 1685 dust concentrations were obtained. For some of the workers repeated measurements were carried out 1 (351) and 2 weeks (326) after the first measurement. Hygiene variables like job, exhaust ventilation, cleaning procedures, etc., were documented. A multivariate analysis based on mixed effects models was used with hygiene variables being fixed effects and worker, machine, department and factory being random effects. A modified stepwise strategy of model making was adopted taking into account the hierarchically structured variables and making possible the exclusion of non-influential random as well as fixed effects. For woodworking, the following determinants of exposure increase the dust concentration: manual and automatic sanding and use of compressed air with fully automatic and semi-automatic machines and for cleaning of work pieces. Decreased dust exposure resulted from the use of compressed air with manual machines, working at fully automatic or semi-automatic machines, functioning exhaust ventilation, work on the night shift, daily cleaning of rooms, cleaning of work pieces with a brush, vacuum cleaning of machines, supplementary fresh air intake and safety representative elected within the last 2 yr. For handling and assembling, increased exposure results from work at automatic machines and presence of wood dust on the workpieces. Work on the evening shift, supplementary fresh air intake, work in a chair factory and special cleaning staff produced decreased exposure to wood dust. The implications of the results for the prevention of wood dust exposure are discussed.

  7. Choice in a Successive-Encounters Procedure and Hyperbolic Decay of Reinforcement

    ERIC Educational Resources Information Center

    Mazur, James E.

    2007-01-01

    Pigeons responded in a successive-encounters procedure that consisted of a search state, a choice state, and a handling state. The search state was either a fixed-interval or mixed-interval schedule presented on the center key of a three-key chamber. Upon completion of the search state, the choice state was presented, in which the center key was…

  8. Impacts of leguminous shrub encroachment on neighboring grasses include transfer of fixed nitrogen.

    PubMed

    Zhang, Hai-Yang; Yu, Qiang; Lü, Xiao-Tao; Trumbore, Susan E; Yang, Jun-Jie; Han, Xing-Guo

    2016-04-01

    Shrub encroachment induced by global change and human disturbance strongly affects ecosystem structure and function. In this study, we explore the degree to which invading leguminous shrubs affected neighboring grasses, including via the transfer of fixed nitrogen (N). We measured N concentrations and natural abundance (15)N of shoot tissues from three dominant grasses from different plant functional groups across seven distances along a local transect (up to 500 cm) to the leguminous shrub, Caragana microphylla. C. microphylla did transfer fixed N to neighboring grasses, but the amount and distance of N transferred were strongly species-specific. Shoot N concentrations decreased significantly with distance from C. microphylla, for a rhizomatous grass, Leymus chinensis, and a bunchgrass, Achnatherum sibiricum. However, N concentrations of another bunchgrass, Stipa grandis, were higher only directly underneath the shrub canopy. Shoot δ(15)N values of L. chinensis were enriched up to 500 cm from the shrub, but for S. grandis were enriched only below the shrub canopy. In contrast, δ(15)N of A. sibiricum did not change along the 500-cm transect. Our results indicated the rhizomatous grass transferred fixed N over long distances while bunchgrasses did not. The presence of C. microphylla increased the shoot biomass of L. chinensis but decreased that of S. grandis and A. sibiricum. These findings highlight the potential role of nutrient-acquisition strategies of neighboring grasses in moderating the interspecific variation of fixed N transfer from the leguminous shrub. Overall, leguminous shrubs have either positive or negative effects on the neighboring grasses and dramatically affect plant community composition and structure.

  9. Robust fixed-time synchronization for uncertain complex-valued neural networks with discontinuous activation functions.

    PubMed

    Ding, Xiaoshuai; Cao, Jinde; Alsaedi, Ahmed; Alsaadi, Fuad E; Hayat, Tasawar

    2017-06-01

    This paper is concerned with the fixed-time synchronization for a class of complex-valued neural networks in the presence of discontinuous activation functions and parameter uncertainties. Fixed-time synchronization not only claims that the considered master-slave system realizes synchronization within a finite time segment, but also requires a uniform upper bound for such time intervals for all initial synchronization errors. To accomplish the target of fixed-time synchronization, a novel feedback control procedure is designed for the slave neural networks. By means of the Filippov discontinuity theories and Lyapunov stability theories, some sufficient conditions are established for the selection of control parameters to guarantee synchronization within a fixed time, while an upper bound of the settling time is acquired as well, which allows to be modulated to predefined values independently on initial conditions. Additionally, criteria of modified controller for assurance of fixed-time anti-synchronization are also derived for the same system. An example is included to illustrate the proposed methodologies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. A model to simulate the haemodynamic effects of right heart pulsatile flow after modified Fontan procedure.

    PubMed

    Tamaki, S; Kawazoe, K; Yagihara, T; Abe, T

    1992-02-01

    The effect of pulsatile pulmonary flow after the modified Fontan procedure was examined in a model that simulated the right heart. An inlet overflow tank (preload), axial pulsatile pump, Wind-Kessel model (afterload), and an outlet overflow tank were connected in series. The standard conditions were flow 2.00 l/min with 12 mm Hg preload pressure, 3.0 Wood units resistance, and an outlet overflow tank pressure at 6 mm Hg. The pump rate was set at 80 beats/min. The simulated pulmonary arterial pressure and pulmonary flow waves produced by this model closely resembled those obtained from patients who had undergone the modified Fontan procedure. All variables except the preload were fixed and changes in pulmonary flow were examined at preload pressures of 8, 12, 15, and 17 mm Hg. As the peak pulmonary arterial pressure increased so did pulmonary flow, until it was greater than during the non-pulsatile state. Because the afterload of this model was fixed, this result suggests that there was a concomitant decrease in resistance. This model indicates that pulsatile pulmonary blood flow is likely to have a beneficial effect on the pulmonary circulation after the modified Fontan procedure.

  11. Cocaine Versus Food Choice Procedure in Rats: Environmental Manipulations and Effects of Amphetamine

    PubMed Central

    Thomsen, Morgane; Barrett, Andrew C.; Negus, S. Stevens; Caine, S. Barak

    2014-01-01

    We have adapted a nonhuman primate model of cocaine versus food choice to the rat species. To evaluate the procedure, we tested cocaine versus food choice under a variety of environmental manipulations as well as pharmacological pretreatments. Complete cocaine-choice dose-effect curves (0–1.0 mg/kg/infusion) were obtained for each condition under concurrent fixed ratio schedules of reinforcement. Percentage of responding emitted on the cocaine-reinforced lever was not affected significantly by removal of cocaine-associated visual or auditory cues, but it was decreased after removal of response-contingent or response-independent cocaine infusions. Cocaine choice was sensitive to the magnitude and fixed ratio requirement of both the cocaine and food reinforcers. We also tested the effects of acute (0.32, 0.56, 1.0, 1.8 mg/kg) and chronic (0.1, 0.32 mg/kg/hr) d-amphetamine treatment on cocaine choice. Acute and chronic d-amphetamine had opposite effects, with acute increasing and chronic decreasing cocaine choice, similar to observations in humans and in nonhuman primates. The results suggest feasibility and utility of the choice procedure in rats and support its comparability to similar procedures used in humans and monkeys. PMID:23319458

  12. Design and Mechanical Evaluation of a Capacitive Sensor-Based Indexed Platform for Verification of Portable Coordinate Measuring Instruments

    PubMed Central

    Avila, Agustín Brau; Mazo, Jorge Santolaria; Martín, Juan José Aguilar

    2014-01-01

    During the last years, the use of Portable Coordinate Measuring Machines (PCMMs) in industry has increased considerably, mostly due to their flexibility for accomplishing in-line measuring tasks as well as their reduced costs and operational advantages as compared to traditional coordinate measuring machines (CMMs). However, their operation has a significant drawback derived from the techniques applied in the verification and optimization procedures of their kinematic parameters. These techniques are based on the capture of data with the measuring instrument from a calibrated gauge object, fixed successively in various positions so that most of the instrument measuring volume is covered, which results in time-consuming, tedious and expensive verification procedures. In this work the mechanical design of an indexed metrology platform (IMP) is presented. The aim of the IMP is to increase the final accuracy and to radically simplify the calibration, identification and verification of geometrical parameter procedures of PCMMs. The IMP allows us to fix the calibrated gauge object and move the measuring instrument in such a way that it is possible to cover most of the instrument working volume, reducing the time and operator fatigue to carry out these types of procedures. PMID:24451458

  13. Design and mechanical evaluation of a capacitive sensor-based indexed platform for verification of portable coordinate measuring instruments.

    PubMed

    Avila, Agustín Brau; Mazo, Jorge Santolaria; Martín, Juan José Aguilar

    2014-01-02

    During the last years, the use of Portable Coordinate Measuring Machines (PCMMs) in industry has increased considerably, mostly due to their flexibility for accomplishing in-line measuring tasks as well as their reduced costs and operational advantages as compared to traditional coordinate measuring machines (CMMs). However, their operation has a significant drawback derived from the techniques applied in the verification and optimization procedures of their kinematic parameters. These techniques are based on the capture of data with the measuring instrument from a calibrated gauge object, fixed successively in various positions so that most of the instrument measuring volume is covered, which results in time-consuming, tedious and expensive verification procedures. In this work the mechanical design of an indexed metrology platform (IMP) is presented. The aim of the IMP is to increase the final accuracy and to radically simplify the calibration, identification and verification of geometrical parameter procedures of PCMMs. The IMP allows us to fix the calibrated gauge object and move the measuring instrument in such a way that it is possible to cover most of the instrument working volume, reducing the time and operator fatigue to carry out these types of procedures.

  14. [Remediation Pb, Cd contaminated soil in lead-zinc mining areas by hydroxyapatite and potassium chloride composites].

    PubMed

    Wang, Li; Li, Yong-Hua; Ji, Yan-Fang; Yang, Lin-Sheng; Li, Hai-Rong; Zhang, Xiu-Wu; Yu, Jiang-Ping

    2011-07-01

    The composite agents containing potassium chloride (KCl) and Hydroxyapatite (HA) were used to remediate the lead and cadmium contaminated soil in Fenghuang lead-zinc mining-smelting areas, Hunan province. The objective of this study was to identify and evaluate the influence of Cl- to the fixing efficiency of Pb and Cd by HA. Two types of contaminated soil (HF-1, HF-2) were chosen and forty treatments were set by five different Hydroxyapatite (HA) dosages and four different Cl- dosages. The toxicity characteristic leaching procedure (TCLP) was used to evaluate the results. It showed that HA could efficiently fix the Pb and Cd from TCLP form. The maximum Pb-fixing efficiency and Cd-fixing efficiency of two types of soil were 83.3%, 97.27% and 35.96%, 57.82% when the HA: Pb: KCl molar ratio was 8: 1: 2. Compared to the fixing efficiency without KCl, KCl at the KCl: Pb molar ratio of 2 improved Pb-fixing efficiency and Cd-fixing efficiency by 6.26%, 0.33% and 7.74%, 0.83% respectively when the HA: Pb molar ratio was 8. Generally, Cl- can improve the Pb/Cd-fixing efficiency in heavy metal contaminated soil by Hydroxyapatite.

  15. 10 CFR 603.695 - Requirements for supplies.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... supplies. An expenditure-based TIA's provisions should permit participants to use their existing procedures to account for and manage supplies. A fixed-support TIA should not include requirements to account...

  16. Minority Population Concentration and Earnings: Evidence from Fixed-Effects Models

    ERIC Educational Resources Information Center

    Johnson, Kecia; Pais, Jeremy; South, Scott J.

    2012-01-01

    Consistent with the hypothesis that heightened visibility and competition lead to greater economic discrimination against minorities, countless studies have observed a negative association between minority population concentration and minority socioeconomic attainment. But minorities who reside in areas with high minority concentration are likely…

  17. Sampling Design and Procedures for Fixed Surface-Water Sites in the Georgia-Florida Coastal Plain Study Unit, 1993

    DTIC Science & Technology

    1995-01-01

    Station number Station drainage area (km2) Land resource province Land-use description Fixed-site type Altamaha River near Everett City, Ga . 02226160...Creek near Tallahassee, Fla. 02326838 27 SCP suburban indicator Little River near Ty Ty, Ga . 02317797 334 SCP agriculture (mixed row crops) indicator...Middle Prong St. Marys River near Taylor, Fla. 02229000 324 CFW silviculture indicator Tucsawhatchee Creek near Hawkinsville, Ga . 02215100 422 SCP

  18. Characterization of the anticonvulsant, behavioral and pharmacokinetic interaction profiles of stiripentol in combination with clonazepam, ethosuximide, phenobarbital, and valproate using isobolographic analysis.

    PubMed

    Luszczki, Jarogniew J; Ratnaraj, Neville; Patsalos, Philip N; Czuczwar, Stanislaw J

    2006-11-01

    Isobolographic analysis was used to characterize the interactions between stiripentol (STP) and clonazepam (CZP), ethosuximide (ETS), phenobarbital (PB), and valproate (VPA) in suppressing pentylenetetrazole (PTZ)-induced clonic seizures in mice. The anticonvulsant and acute adverse (neurotoxic) effects of STP in combination with the various conventional antiepileptic drugs (AEDs), at fixed ratios of 1:3, 1:1, and 3:1, were evaluated in the PTZ and chimney tests in mice using the isobolographic analysis. Additionally, protective indices (PI) and benefit indices (BI) were calculated to identify their pharmacological profiles so that a ranking in relation to advantageous combination could be established. Moreover, adverse-effect paradigms were determined by use of the step-through passive avoidance task (long-term memory), threshold for the first pain reaction, grip-strength test (neuromuscular tone), and the hot plate test (acute thermal pain). Brain AED concentrations were also measured so as to ascertain any pharmacokinetic contribution to the pharmacodynamic interactions. All AED combinations comprising of STP and CZP, ETS, PB, and VPA (at the fixed ratios of 1:3, 1:1 and 3:1) were additive in terms of clonic seizure suppression in the PTZ test. However, these interactions were complicated by changes in brain AED concentrations consequent to pharmacokinetic interactions. Thus STP significantly increased total brain ETS and PB concentrations, and decreased VPA concentrations, but was without effect on CZP concentrations. In contrast, PB significantly decreased and VPA increased total brain STP concentrations while CZP and ETS were without effect. Furthermore, while isobolographic analysis revealed that STP and CZP in combination, at the fixed ratios of 1:1 and 3:1, were supraadditive (synergistic; p < 0.05), the combinations of STP with CZP (1:3), ETS, PB, or VPA (at all fixed ratios of 1:3, 1:1, and 3:1) were barely additivity in terms of acute neurotoxic adverse effects in the chimney test. Additionally, none of the examined combinations of STP with conventional AEDs (CZP, ETS, PB, VPA--at their median effective doses from the PTZ-test) affected long-term memory, threshold for the first pain reaction, neuromuscular tone, and acute thermal pain. Based on BI values, the combination of STP with PB at the fixed ratio of 1:3 appears to be a particularly favourable combination. In contrast, STP and CZP or ETS (at the fixed ratios of 1:1 and 3:1) were unfavorable combinations. However, these conclusions are confounded by the fact that STP is associated with significant pharmacokinetic interactions. The remaining combinations of STP with PB (1:1 and 3:1), CZP (1:3), ETS (1:3), and VPA (at all fixed ratios of 1:3, 1:1, and 3:1) do not appear to be potential favorable AED combinations.

  19. Ocular pharmacokinetics and tolerability of bimatoprost ophthalmic solutions administered once or twice daily in rabbits, and clinical dosing implications

    PubMed Central

    Shen, Jie; Goodkin, Margot L; Tong, Warren; Attar, Mayssa

    2017-01-01

    Purpose Fixed-combination medications can benefit patients requiring multiple agents to lower their intraocular pressure (IOP), but combining agents with complementary mechanisms of action is challenging if their dosing frequency differs. This study compares in vivo pharmacokinetic and ocular tolerability of bimatoprost 0.01% ophthalmic solutions dosed once or twice daily. Reports of twice-daily dosing in glaucoma patients are also reviewed. Methods New Zealand White rabbits were administered bimatoprost 0.01% monotherapy or fixed-combination bimatoprost 0.01%/brimonidine 0.1%, once or twice daily in both eyes for 4 days. Ocular tissues were harvested and analyzed by liquid chromatography-tandem mass spectrometry. The pharmacokinetic parameters calculated included maximum observed concentration, time to maximum concentration, and area under the concentration-time curve. Results Due to extensive metabolism, bimatoprost concentration was below the quantitation limit by 1 hour post-dose in all samples. Bimatoprost acid exposure, however, could be measured up to 6–8 hours post-dose and was similar in the aqueous humor and iris-ciliary body (pharmacological site of action) of animals treated once or twice daily with either bimatoprost 0.01% or fixed-combination bimatoprost 0.01%/brimonidine 0.1%. Increasing dosage frequency in rabbits did not raise the incidence of drug-related conjunctival hyperemia (most common adverse event associated with bimatoprost use in humans), suggesting comparable ocular tolerability of the once- and twice-daily regimens for each formulation. Conclusion Bimatoprost 0.01% administered once or twice daily as monotherapy and in fixed-combination with brimonidine 0.1% in rabbits show similar pharmacokinetic profiles of bimatoprost acid, especially in the iris-ciliary body. Key findings from previous clinical studies suggest that by varying the concentration of benzalkonium chloride (a preservative with corneal penetration-enhancing properties), formulations of bimatoprost 0.01% can be administered once or twice daily. These findings support development of bimatoprost 0.01%-based fixed-dose combination therapies administered twice daily for patients who require multiple adjunctive medications to control their IOP. PMID:29026287

  20. Collecting a better water-quality sample: Reducing vertical stratification bias in open and closed channels

    USGS Publications Warehouse

    Selbig, William R.

    2017-01-01

    Collection of water-quality samples that accurately characterize average particle concentrations and distributions in channels can be complicated by large sources of variability. The U.S. Geological Survey (USGS) developed a fully automated Depth-Integrated Sample Arm (DISA) as a way to reduce bias and improve accuracy in water-quality concentration data. The DISA was designed to integrate with existing autosampler configurations commonly used for the collection of water-quality samples in vertical profile thereby providing a better representation of average suspended sediment and sediment-associated pollutant concentrations and distributions than traditional fixed-point samplers. In controlled laboratory experiments, known concentrations of suspended sediment ranging from 596 to 1,189 mg/L were injected into a 3 foot diameter closed channel (circular pipe) with regulated flows ranging from 1.4 to 27.8 ft3 /s. Median suspended sediment concentrations in water-quality samples collected using the DISA were within 7 percent of the known, injected value compared to 96 percent for traditional fixed-point samplers. Field evaluation of this technology in open channel fluvial systems showed median differences between paired DISA and fixed-point samples to be within 3 percent. The range of particle size measured in the open channel was generally that of clay and silt. Differences between the concentration and distribution measured between the two sampler configurations could potentially be much larger in open channels that transport larger particles, such as sand.

  1. Seating type and cognitive performance after 3 hours travel by high-speed boat in sea states 2-3.

    PubMed

    McMorris, Terry; Myers, Stephen; Dobbins, Trevor; Hall, Ben; Dyson, Rosemary

    2009-01-01

    Transit in high-speed marine craft subjects occupants to a rough ride as the boat impacts the waves. This induces high levels of physical stress, which may inhibit cognitive performance during military operations and life-saving activities. Land-based research suggests that suspension seats reduce vibration and, therefore, stress. We hypothesized that subjects using suspension seats would demonstrate better cognitive performance, lower perceptions of exertion, fatigue, and sleepiness, and lower salivary concentrations of cortisol than those using fixed seats. Subjects, naval personnel, were divided into fixed (N = 6) and suspension seat (N = 6) groups. Subjects undertook forward and backward number recall and random number generation tests pre- and post-transit (3 h in sea states 2-3). Salivary cortisol concentrations were sampled pre- (1100 h) and post-transit (1700 h) and at the same times on a control day. Post-transit perceptions of exertion, fatigue, and sleepiness were measured subjectively. The suspension seat group demonstrated better performance post-transit than the fixed seat group for forward number recall and showed a significant pre- to post-transit improvement in backward number recall. The suspension seat group reported less fatigue and sleepiness. The suspension seat group had significantly higher salivary cortisol concentrations than the fixed seat group post-transit. Regression analyses found a quadratic correlation between delta cortisol concentrations and delta random number generation scores (R2 = 0.68). Results show that the use of suspension seats during transit in high-speed marine craft may be advantageous with regard to cognitive performance.

  2. 49 CFR 659.13 - Overview.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... TRANSPORTATION RAIL FIXED GUIDEWAY SYSTEMS; STATE SAFETY OVERSIGHT Role of the State Oversight Agency § 659.13... oversight agency must oversee the execution of these practices and procedures, to ensure compliance with the...

  3. Location identifiers

    DOT National Transportation Integrated Search

    1997-01-30

    This order lists the location identifiers authorized by the Federal Aviation Administration, Department of the Navy, and Transport Canada. It lists United States airspace fixes and procedure codes. The order also includes guidelines for requesting id...

  4. 45 CFR 1310.17 - Driver and bus monitor training.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... safe and efficient manner; (2) safely run a fixed route, including loading and unloading children... first aid in case of injury; (4) handle emergency situations, including vehicle evacuation procedures...

  5. Robot-assisted versus laparoscopic rectal resection for cancer in a single surgeon's experience: a cost analysis covering the initial 50 robotic cases with the da Vinci Si.

    PubMed

    Morelli, Luca; Guadagni, Simone; Lorenzoni, Valentina; Di Franco, Gregorio; Cobuccio, Luigi; Palmeri, Matteo; Caprili, Giovanni; D'Isidoro, Cristiano; Moglia, Andrea; Ferrari, Vincenzo; Di Candio, Giulio; Mosca, Franco; Turchetti, Giuseppe

    2016-09-01

    The aim of this study is to compare surgical parameters and the costs of robotic surgery with those of laparoscopic approach in rectal cancer based on a single surgeon's early robotic experience. Data from 25 laparoscopic (LapTME) and the first 50 robotic (RobTME) rectal resections performed at our institution by an experienced laparoscopic surgeon (>100 procedures) between 2009 and 2014 were retrospectively analyzed and compared. Patient demographic, procedure, and outcome data were gathered. Costs of the two procedures were collected, differentiated into fixed and variable costs, and analyzed against the robotic learning curve according to the cumulative sum (CUSUM) method. Based on CUSUM analysis, RobTME group was divided into three phases (Rob1: 1-19; Rob2: 20-40; Rob3: 41-50). Overall median operative time (OT) was significantly lower in LapTME than in RobTME (270 vs 312.5 min, p = 0.006). A statistically significant change in OT by phase of robotic experience was detected in the RobTME group (p = 0.010). Overall mean costs associated with LapTME procedures were significantly lower than with RobTME (p < 0.001). Statistically significant reductions in variable and overall costs were found between robotic phases (p < 0.009 for both). With fixed costs excluded, the difference between laparoscopic and Rob3 was no longer statistically significant. Our results suggest a significant optimization of robotic rectal surgery's costs with experience. Efforts to reduce the dominant fixed cost are recommended to maintain the sustainability of the system and benefit from the technical advantages offered by the robot.

  6. Separation and purification of fructooligosaccharides on a zeolite fixed-bed column.

    PubMed

    Kuhn, Raquel Cristine; Mazutti, Marcio Antonio; Maugeri Filho, Francisco

    2014-04-01

    Fructooligosaccharides (FOS), a well-known prebiotic product, are obtained by enzymatic synthesis and consist of a mixture of mono- and disaccharides. In this work, a methodology for their separation and purification was developed using a zeolite fixed-bed column. The effects of column temperature (40-60°C), eluent flow rate (0.10-0.14 mL/min), injected to bed volume percent ratio (2.6-5.1%), and ethanol concentration in the eluent (40-60%, v/v) were investigated using a fractionary factorial design (2(4-1)), having the separation efficiency and purity as target responses. Additional experiments were performed as well, where the temperature and ethanol concentration were studied in a central composite design (2(2)). In this work, the zeolite fixed-bed column was shown to be a good alternative for FOS purification, allowing a FOS purity of 90% and separation efficiency of 6.86 between FOS and glucose, using an eluent at 45°C with 60% ethanol concentration. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Surface-water-quality assessment of the upper Illinois River Basin in Illinois, Indiana, and Wisconsin; fixed-station network and selected water-quality data for April 1987-September 1990

    USGS Publications Warehouse

    Sullivan, Daniel J.; Blanchard, Stephen F.

    1994-01-01

    This report describes and presents the sampling design, methods, quality assurance methods and results, and information on how to obtain data collected at eight fixed stations in the upper Illinois River Basin as part of the pilot phase of the National Water-Quality Assessment program. Data were collected monthly from April 1987-August l990; these data were supplemented with data collected during special events, including high and low flows. Each fixed station represents a cross section at which the transport of selected dissolved and suspended materials can be computed. Samples collected monthly and during special events were analyzed for concentrations of major ions, nutrients, trace elements, organic carbon, chlorophyll-a, suspended sediment, and other constituents. Field measurements of water temperature, pH, dissolved oxygen, specific conductance, and indicator bacteria also were made at each site. Samples of suspended sediment were analyzed for concentrations of major ions and trace elements. In addition, samples were analyzed seasonally for concentrations of antimony, bromide, molybdenum, and the radionuclides gross alpha and gross beta.

  8. Effect of layer thickness on the thermal release from Be-D co-deposited layers

    NASA Astrophysics Data System (ADS)

    Baldwin, M. J.; Doerner, R. P.

    2014-08-01

    The results of previous work (Baldwin et al 2013 J. Nucl. Mater. 438 S967-70 and Baldwin et al 2014 Nucl. Fusion 54 073005) are extended to explore the influence of layer thickness on the thermal D2 release from co-deposited Be-(0.05)D layers produced at ˜323 K. Bake desorption of layers of thickness 0.2-0.7 µm are explored with a view to examine the influence of layer thickness on the efficacy of the proposed ITER bake procedure, to be carried out at the fixed temperatures of 513 K on the first wall and 623 K in the divertor. The results of experiment and modelling with the TMAP-7 hydrogen transport code, show that thicker Be-D co-deposited layers are relatively more difficult to desorb (time-wise) than thinner layers with the same concentrations of intrinsic traps and retained hydrogen isotope fraction.

  9. Colloidal chitin stained with Remazol Brilliant Blue R, a useful substrate to select chitinolytic microorganisms and to evaluate chitinases.

    PubMed

    Gómez Ramírez, M; Rojas Avelizapa, L I; Rojas Avelizapa, N G; Cruz Camarillo, R

    2004-02-01

    A simple and sensitive method based on the use of colloidal chitin stained with Remazol Brilliant Blue R (RBB) is proposed to evaluate chitinase activity. If this colloidal-stained substrate is included as a carbon source in a liquid medium, this technique allows the selection or the comparison of chitinolytic microorganisms. The colloidal substrate is proportionally solubilized and the dye released is spectrophotometrically quantified at 595 nm. The procedures used for the staining and fixing of RBB in the colloidal chitin, and a comparison with the commercial substrate chitin-azure, are presented. The influence of several physicochemical and enzymatic parameters on the release of dyes is also shown. Both stained substrates were used for studying the effect of pH, substrate concentration, temperature and time on the chitinase reaction of Bacillus thuringiensis Bt-107.

  10. CONCENTRATIONS AND ESTIMATED LOADS OF NITROGEN CONTRIBUTED BY TWO ADJACENT WETLAND STREAMS WITH DIFFERENT FLOW-SOURCE TERMS IN WATKINSVILLE, GA

    EPA Science Inventory

    Inorganic, fixed nitrogen from agricultural settings often is introduced to first-order streams via surface runoff and shallow ground-water flow. Best management practices for limiting the flux of fixed N to surface waters often include buffers such as wetlands. However, the eff...

  11. Fixed and equilibrium endpoint problems in uneven-aged stand management

    Treesearch

    Robert G. Haight; Wayne M. Getz

    1987-01-01

    Studies in uneven-aged management have concentrated on the determination of optimal steady-state diameter distribution harvest policies for single and mixed species stands. To find optimal transition harvests for irregular stands, either fixed endpoint or equilibrium endpoint constraints can be imposed after finite transition periods. Penalty function and gradient...

  12. CONCENTRATIONS AND ESTIMATED LOADS OF NITROGEN CONTRIBUTED BY TWO ADJACENT WETLAND STREAMS WITH DIFFERENT FLOW-SOURCE TERMS IN WATKINSVILLE, GEORGIA

    EPA Science Inventory

    Inorganic, fixed nitrogen from agricultural settings often is introduced to first-order streams via surface runoff and shallow ground-water flow. Best management practices for limiting the flux of fixed N to surface waters often include buffers such as wetlands. However, the eff...

  13. 47 CFR 27.3 - Other applicable rule parts.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Commission Field Offices. (b) Part 1. This part includes rules of practice and procedure for license...) Part 101. This part sets forth the requirements and conditions applicable to fixed microwave services...

  14. Donation return time at fixed and mobile donation sites

    PubMed Central

    Carey, Patricia M.; High, Patrick M.; Schlumpf, Karen S.; Johnson, Bryce R.; Mast, Alan E.; Rios, Jorge A.; Simon, Toby L.; Wilkinson, Susan L.

    2013-01-01

    BACKGROUND This study investigated the effect of blood donation environment, fixed or mobile with differing sponsor types, on donation return time. STUDY DESIGN AND METHODS Data from 2006 through 2009 at six US blood centers participating in the Retrovirus Epidemiology Donor Study-II (REDS-II) were used for analysis. Descriptive statistics stratified by whole blood (WB), plateletpheresis (PP), and double red blood cell (R2) donations were obtained for fixed and mobile locations, including median number of donations and median interdonation interval. A survival analysis estimated median return time at fixed and mobile sites, while controlling for censored return times, demographics, blood center, and mandatory recovery times. RESULTS Two-thirds (67.9%) of WB donations were made at mobile sites, 97.4% of PP donations were made at fixed sites, and R2 donations were equally distributed between fixed and mobile locations. For donations at fixed sites only or alternating between fixed and mobile sites, the highest median numbers of donations were nine and eight, respectively, and the shortest model-adjusted median return times (controlling for mandatory eligibility times of 56 and 112 days) were 36 and 30 days for WB and R2 donations, respectively. For PP donations, the shortest model-adjusted median return time was 23 days at a fixed location and the longest was 693 days at community locations. CONCLUSION WB, PP, and R2 donors with the shortest time between donations were associated with fixed locations and those alternating between fixed and mobile locations, even after controlling for differing mandatory recovery times for the different blood donation procedures. PMID:21745215

  15. Simultaneous control of apparent extract and volatile compounds concentrations in low-malt beer fermentation.

    PubMed

    Kobayashi, Michiko; Nagahisa, Keisuke; Shimizu, Hiroshi; Shioya, Suteaki

    2006-12-01

    Volatile compounds cause undesirable flavor when their concentrations exceed threshold values in beer fermentation. The objective of this study is to develop a system for controlling apparent extract concentration, which indicates the fermentation degree and which should be decreased below a targeted value at a fixed time under a constraint of tolerable amounts of volatile compounds. In beer fermentation, even though the production of volatile compounds is suppressed by maintaining a low fermentation temperature, a low temperature causes a delay in the control of apparent extract concentration. Volatile compound concentration was estimated on-line, and the simulation of apparent extract consumption and volatile compound production was performed. To formulate various beer tastes and conserve energy for attemperation, optimal temperature profiles were determined using a genetic algorithm (GA). The developed feedback control of the brewing temperature profile was successfully applied, and apparent extract and volatile compound concentrations at a fixed time reached their target concentrations. Additionally, the control technique developed in this study enables us to brew a wide variety of beers with different tastes.

  16. Estimating equations estimates of trends

    USGS Publications Warehouse

    Link, W.A.; Sauer, J.R.

    1994-01-01

    The North American Breeding Bird Survey monitors changes in bird populations through time using annual counts at fixed survey sites. The usual method of estimating trends has been to use the logarithm of the counts in a regression analysis. It is contended that this procedure is reasonably satisfactory for more abundant species, but produces biased estimates for less abundant species. An alternative estimation procedure based on estimating equations is presented.

  17. Fibroblast Activation Protein-Alpha, a Serine Protease that Facilitates Metastasis by Modification of Diverse Microenvironments

    DTIC Science & Technology

    2011-10-01

    lung tissue. We were not able to detect sufficient numbers of cells in this manner. We tried a different procedure for fixing the lungs after they...added after 24 hours. The films were fixed and evaluated microscopically. In four trials, 10 random microscopic fields were selected and... dosing by oral gavage once daily with 1.3 mg/kg L-valine-L-boroproline called talabostat (extracellular & intracellular DASH), 13.3 mg/kg L- glutamyl

  18. STS-46 crewmembers participate in Fixed Base (FB) SMS training at JSC

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-46 Atlantis, Orbiter Vehicle (OV) 104, Mission Specialist (MS) and Payload Commander (PLC) Jeffrey A. Hoffman, standing at the interdeck access ladder, explains procedures to backup Italian Payload Specialist Umberto Guidoni (center) and Italian Payload Specialist Franco Malerba (right) on the middeck of JSC's fixed base (FB) shuttle mission simulator (SMS). Behind them, MS Marsha S. Ivins reviews a cheklist. Participants are wearing communications kit assembly lightweight headsets (HDSTs). FB-SMS is located in JSC's Mission Simulation and Training Facility Bldg 5.

  19. 32 CFR 37.700 - What are the requirements for supplies?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-based TIA's provisions should permit participants to use their existing procedures to account for and manage supplies. A fixed-support TIA should not include requirements to account for or manage supplies...

  20. 47 CFR 78.3 - Other pertinent rules.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... chapter: Part 0—Commission Organization. Part 1—Practice and Procedure. Part 2—Frequency Allocations and... Antenna Structures. Part 21—Domestic Public Fixed Radio Services. Part 74—Experimental, Auxiliary, and...

  1. 47 CFR 1.992 - How to calculate indirect equity and voting interests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... PROCEDURE Grants by Random Selection Wireless Radio Services Applications and Proceedings Foreign Ownership of Common Carrier, Aeronautical En Route, and Aeronautical Fixed Radio Station Licensees § 1.992 How...

  2. 47 CFR 1.992 - How to calculate indirect equity and voting interests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... PROCEDURE Grants by Random Selection Wireless Radio Services Applications and Proceedings Foreign Ownership of Common Carrier, Aeronautical En Route, and Aeronautical Fixed Radio Station Licensees § 1.992 How...

  3. Microbiological characteristics of a sandy loam soil exposed to tebuconazole and lambda-cyhalothrin under laboratory conditions.

    PubMed

    Cycoń, M; Piotrowska-Seget, Z; Kaczyńska, A; Kozdrój, J

    2006-11-01

    Changes in microbiological properties of a sandy loam soil in response to the addition of different concentrations of fungicide tebuconazole and pyrethroid insecticide lambda-cyhalothrin were assessed under laboratory conditions. To ascertain these changes, the potentially active soil microbial biomass, concentrations of ammonium and nitrate ions, numbers of total culturable bacteria, fungi, nitrogen-fixing bacteria, nitrifying and denitrifying bacteria were determined. Substrate-induced respiration (SIR) increased with time in both control (ranged from 13.7 to 23.7 mg/O(2)/kg(-1)/dry soil/h(-1)) and pesticide treated soil portions. For both pesticides, SIR values ranged from 12-13 to 23-25 mg/O(2)/kg(-1)/dry soil/h(-1) on days 1 and 28, respectively. Also, concentrations of nitrate and ammonium ions, numbers of total culturable bacteria, denitrifying bacteria, nitrogen-fixing bacteria (for the insecticide) and fungi (for the insecticide) were either unaffected or even stimulated by the pesticide treatments. The adverse impacts of the pesticides were observed for nitrate concentrations (on days 1 or 7), numbers of nitrifying bacteria (on day 1), denitrifying bacteria (for the insecticide on days 1 and 14), nitrogen-fixing bacteria (for tebuconazole on day 1) as well as numbers of fungi in tebuconazole-treated soil (on days 1 and 14).

  4. Frequency-Dependent Capacitance of Hydrophobic Membranes Containing Fixed Negative Charges

    PubMed Central

    Ilani, Asher

    1968-01-01

    Filters containing fixed negative charges were saturated with hydrophobic solvent and interposed between aqueous solutions. The capacitance of such membranes was measured in the frequency range of 0.05-30 kc. The capacitance increased with decrease in frequency. The frequency dependence of the capacitance was sensitive to nature of the cation present and to salt concentration in the aqueous solution. It is suggested that variation of membrane resistivity in the space charge region of the membrane is responsible for this phenomenon. Possible effects of the potential and counterion concentration profiles at the membrane-water interface are discussed. PMID:5699796

  5. Experimental evaluation of a fixed collector employing vee-trough concentrator and vacuum tube receivers

    NASA Technical Reports Server (NTRS)

    Selcuk, M. K.

    1977-01-01

    A test bed for experimental evaluation of a fixed solar collector which combines an evacuated glass tube solar receiver with a flat plate/black chrome plated copper absorber and an asymmetric vee-trough concentrator was designed and constructed. Earlier predictions of thermal performance were compared with test data acquired for a bare vacuum tube receiver; and receiver tubes with Alzak aluminum, aluminized FEP Teflon film laminated sheet metal and second surface ordinary mirror reflectors. Test results and system economics as well as objectives of an ongoing program to obtain long-term performance data are discussed.

  6. Transforaminal Anterior Release for the Treatment of Fixed Sagittal Imbalance and Segmental Kyphosis, Minimum 2-Year Follow-Up Study.

    PubMed

    Sweet, Fred A; Sweet, Andrea

    2015-09-01

    Retrospective review of prospectively accrued patient cohort. To report minimum 2 years' follow-up after a single-surgeon series of 47 consecutive patients in whom fixed sagittal imbalance or segmental kyphosis was treated with a novel unilateral transforaminal annular release. Fixed sagittal imbalance has been treated most recently with pedicle subtraction osteotomy with great success but is associated with significant blood loss and neurologic risk. Forty-seven consecutive patients with fixed sagittal imbalance (n = 29) or segmental kyphosis (n = 18) were treated by a single surgeon with a single-level transforaminal anterior release (TFAR) to effect an opening wedge correction. Sagittal and coronal correction was performed with in situ rod contouring. An interbody cage was captured in the disc space with rod compression. Radiographic and clinical outcome analysis was performed with a minimum 2-year follow-up (range 2-7.8 years). The average increase in lordosis was 36° (range 24°-56°) in the fixed sagittal deformity group. Coronal corrections averaged 34° (range 18°-48°). The average improvement in plumb line was 13.6 cm. There were four pseudarthroses, one at the TFAR. Average blood loss was 578 mL (range 200-1,200). One patient had a transient grade 4/5 anterior tibialis weakness. There were no vascular injuries or permanent neurologic deficits. There were significant improvements in the Oswestry Disability Index (p < .001) and Scoliosis Research Society Questionnaire scores (p = .003). Eighty-four percent of patients reported improvement in pain, self-image, and satisfaction with the procedure. TFAR is a useful procedure for correcting segmental kyphosis and fixed sagittal imbalance with relatively low blood loss and was found to be neurologically safe in this single-surgeon series. Therapeutic study, Level IV (case series, no control group). Copyright © 2015 Scoliosis Research Society. Published by Elsevier Inc. All rights reserved.

  7. Matrix product density operators: Renormalization fixed points and boundary theories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cirac, J.I.; Pérez-García, D., E-mail: dperezga@ucm.es; ICMAT, Nicolas Cabrera, Campus de Cantoblanco, 28049 Madrid

    We consider the tensors generating matrix product states and density operators in a spin chain. For pure states, we revise the renormalization procedure introduced in (Verstraete et al., 2005) and characterize the tensors corresponding to the fixed points. We relate them to the states possessing zero correlation length, saturation of the area law, as well as to those which generate ground states of local and commuting Hamiltonians. For mixed states, we introduce the concept of renormalization fixed points and characterize the corresponding tensors. We also relate them to concepts like finite correlation length, saturation of the area law, as well asmore » to those which generate Gibbs states of local and commuting Hamiltonians. One of the main result of this work is that the resulting fixed points can be associated to the boundary theories of two-dimensional topological states, through the bulk-boundary correspondence introduced in (Cirac et al., 2011).« less

  8. Histological evaluation of oral maintenance programs upon gingival condition in orthodontic patients.

    PubMed

    Hănţoiu, Tudor Alexandru; Hănţoiu, Liana Georgiana; Monea, Adriana

    2015-01-01

    The aim of the study was to conduct a histological evaluation of gingival condition in patients under orthodontic treatment with fixed appliances, according to different oral hygiene maintenance programs. We performed a randomized prospective study on 36 patients with fixed orthodontic appliances (17-25 years of age) divided in three study groups. The investigations were represented by measurements of plaque index and sulcular bleeding index, followed by pathological examination of specimens from gingival tissue. Treatment of orthodontic patients must follow an interdisciplinary approach. All modalities of oral hygiene procedures and their effect on the periodontal tissues must be explained to the patient prior to fixed orthodontic treatment. Fixed orthodontics do not induce periodontal disease if basic principles of oral hygiene are followed in compliant patients, which are correctly instructed to deal with real challenge, represented by complete elimination of debris and bacterial accumulation.

  9. Coordinate transformations and gauges in the relativistic astronomical reference systems

    NASA Astrophysics Data System (ADS)

    Tao, J.-H.; Huang, T.-Y.; Han, C.-H.

    2000-11-01

    This paper applies a fully post-Newtonian theory (Damour et al. 1991, 1992, 1993, 1994) to the problem of gauge in relativistic reference systems. Gauge fixing is necessary when the precision of time measurement and application reaches 10-16 or better. We give a general procedure for fixing the gauges of gravitational potentials in both the global and local coordinate systems, and for determining the gauge functions in all the coordinate transformations. We demonstrate that gauge fixing in a gravitational N-body problem can be solved by fixing the gauge of the self-gravitational potential of each body and the gauge function in the coordinate transformation between the global and local coordinate systems. We also show that these gauge functions can be chosen to make all the coordinate systems harmonic or any as required, no matter what gauge is chosen for the self-gravitational potential of each body.

  10. Short-term memory for responses: the "choose-small" effect.

    PubMed Central

    Fetterman, J G; MacEwen, D

    1989-01-01

    Pigeons' short-term memory for fixed-ratio requirements was assessed using a delayed symbolic matching-to-sample procedure. Different choices were reinforced after fixed-ratio 10 and fixed-ratio 40 requirements, and delays of 0, 5, or 20 s were sometimes placed between sample ratios and choice. All birds made disproportionate numbers of responses to the small-ratio choice alternative when delays were interposed between ratios and choice, and this bias increased as a function of delay. Preference for the small fixed-ratio alternative was also observed on "no-sample" trials, during which the choice alternatives were presented without a prior sample ratio. This "choose-small" bias is analogous to results obtained by Spetch and Wilkie (1983) with event duration as the discriminative stimulus. The choose-small bias was attenuated when the houselight was turned on during delays, but overall accuracy was not influenced systematically by the houselight manipulation. PMID:2584917

  11. INDOOR AEROSOLS AND EXPOSURE ASSESSMENT

    EPA Science Inventory

    This chapter provides an overview of both indoor aerosol concentration measurements, and the considerations for assessment of exposure to aerosols in non-occupational settings. The fixed-location measurements of concentration at an outdoor location, while commuting inside an a...

  12. A benthic-macroinvertebrate index of biotic integrity and assessment of conditions in selected streams in Chester County, Pennsylvania, 1998-2009

    USGS Publications Warehouse

    Reif, Andrew G.

    2012-01-01

    The Stream Conditions of Chester County Biological Monitoring Network (Network) was established by the U.S. Geological Survey and the Chester County Water Resources Authority in 1969. Chester County encompasses 760 square miles in southeastern Pennsylvania and has a rapidly expanding population. Land-use change has occurred in response to this continual growth, as open space, agricultural lands, and wooded lands have been converted to residential and commercial lands. In 1998, the Network was modified to include 18 fixed-location sites and 9 flexible-location sites. Sites were sampled annually in the fall (October-November) during base-flow conditions for water chemistry, instream habitat, and benthic macroinvertebrates. A new set of 9 flexible-location sites was selected each year. From 1998 to 2009, 213 samples were collected from the 18 fixed-location sites and 107 samples were collected from the 84 flexible-location sites. Eighteen flexible-location sites were sampled more than once over the 12-year period; 66 sites were sampled only once. Benthic-macroinvertebrate data from samples collected during 1998-2009 were used to establish the Chester County Index of Biotic Integrity (CC-IBI). The CC-IBI was based on the methods and metrics outlined in the Pennsylvania Department of Environmental Protection's "A Benthic Index of Biotic Integrity for Wadeable Freestone Streams in Pennsylvania." The resulting CC-IBI consists of scores for benthic-macroinvertebrate samples collected from sites in the Network that related to reference conditions in Chester County. Mean CC-IBI scores for 18 fixed-location sites ranged from 37.21 to 88.92. Thirty-nine percent of the 213 samples collected at the 18 fixed-location sites had a CC-IBI score less than 50; 33 percent, 50 to 70; 28 percent, greater than 70. CC-IBI scores from the 107 flexible-location samples ranged from 23.48 to 99.96. Twenty-five percent of the 107 samples collected at the flexible-location sites had a CC-IBI score less than 50; 33 percent, 50 to 70; and 42 percent, greater than 70. Factors that were found to affect CC-IBI scores are nutrient concentrations, habitat conditions, and percent of wooded and urban land use. A positive relation was determined between mean CC-IBI scores and mean total habitat scores for the 18 fixed-location sites. CC-IBI scores were most strongly affected by stream bank vegetative protection, embeddedness, riparian zone width, and sediment deposition. The highest CC-IBI scores were associated with sites that had greater than 28 percent wooded-wetland-water land use, less than 5 percent urban land use, and no municipal wastewater discharges within 10 miles upstream from the sampling site. The lowest CC-IBI scores were associated with sites where urban land use was greater than 15 percent or a municipal wastewater discharge was within 10 miles upstream from the sampling reach. The Mann Kendall test for trends was used to determine trends in CC-IBI scores and concentrations of nitrate, orthophosphate, and chloride for the 18 fixed-location sites. A positive trend in CC-IBI was determined for six sites, and a negative trend was determined for one site. Positive trends in nitrate concentrations were determined for 4 of the 18 fixed-location sites, and a negative trend in orthophosphate concentrations was determined for 1 of the 18 fixed-location sites. Positive trends in chloride concentrations were determined for 16 of the 18 fixed-location sites.

  13. Second-order schedules: comparison of different procedures for scheduling paired and nonpaired brief stimuli.

    PubMed

    Stubbs, D A; Cohen, S L

    1972-11-01

    Pigeons performed on a second-order schedule in which fixed-interval components were maintained under a variable-interval schedule. Completion of each fixed-interval component resulted in a brief-stimulus presentation and/or food. The relation of the brief stimulus and food was varied across conditions. Under some conditions, the brief stimulus was never paired with food. Under other conditions, the brief stimulus was paired with food; three different pairing procedures were used: (a) a response produced the simultaneous onset of the stimulus and food; (b) a response produced the stimulus before food with the stimulus remaining on during food presentation; (c) a response produced the stimulus and the offset of the stimulus was simultaneous with the onset of the food cycle. The various pairing and nonpairing operations all produced similar effects on performance. Under all conditions, response rates were positively accelerated within fixed-interval components. Total response rates and Index of Curvature measures were similar across conditions. In one condition, a blackout was paired with food; with this different stimulus in effect, less curvature resulted. The results suggest that pairing of a stimulus is not a necessary condition for within-component patterning under some second-order schedules.

  14. Second-order schedules: comparison of different procedures for scheduling paired and nonpaired brief stimuli

    PubMed Central

    Stubbs, D. Alan; Cohen, Steven L.

    1972-01-01

    Pigeons performed on a second-order schedule in which fixed-interval components were maintained under a variable-interval schedule. Completion of each fixed-interval component resulted in a brief-stimulus presentation and/or food. The relation of the brief stimulus and food was varied across conditions. Under some conditions, the brief stimulus was never paired with food. Under other conditions, the brief stimulus was paired with food; three different pairing procedures were used: (a) a response produced the simultaneous onset of the stimulus and food; (b) a response produced the stimulus before food with the stimulus remaining on during food presentation; (c) a response produced the stimulus and the offset of the stimulus was simultaneous with the onset of the food cycle. The various pairing and nonpairing operations all produced similar effects on performance. Under all conditions, response rates were positively accelerated within fixed-interval components. Total response rates and Index of Curvature measures were similar across conditions. In one condition, a blackout was paired with food; with this different stimulus in effect, less curvature resulted. The results suggest that pairing of a stimulus is not a necessary condition for within-component patterning under some second-order schedules. PMID:16811634

  15. Methods for selecting fixed-effect models for heterogeneous codon evolution, with comments on their application to gene and genome data.

    PubMed

    Bao, Le; Gu, Hong; Dunn, Katherine A; Bielawski, Joseph P

    2007-02-08

    Models of codon evolution have proven useful for investigating the strength and direction of natural selection. In some cases, a priori biological knowledge has been used successfully to model heterogeneous evolutionary dynamics among codon sites. These are called fixed-effect models, and they require that all codon sites are assigned to one of several partitions which are permitted to have independent parameters for selection pressure, evolutionary rate, transition to transversion ratio or codon frequencies. For single gene analysis, partitions might be defined according to protein tertiary structure, and for multiple gene analysis partitions might be defined according to a gene's functional category. Given a set of related fixed-effect models, the task of selecting the model that best fits the data is not trivial. In this study, we implement a set of fixed-effect codon models which allow for different levels of heterogeneity among partitions in the substitution process. We describe strategies for selecting among these models by a backward elimination procedure, Akaike information criterion (AIC) or a corrected Akaike information criterion (AICc). We evaluate the performance of these model selection methods via a simulation study, and make several recommendations for real data analysis. Our simulation study indicates that the backward elimination procedure can provide a reliable method for model selection in this setting. We also demonstrate the utility of these models by application to a single-gene dataset partitioned according to tertiary structure (abalone sperm lysin), and a multi-gene dataset partitioned according to the functional category of the gene (flagellar-related proteins of Listeria). Fixed-effect models have advantages and disadvantages. Fixed-effect models are desirable when data partitions are known to exhibit significant heterogeneity or when a statistical test of such heterogeneity is desired. They have the disadvantage of requiring a priori knowledge for partitioning sites. We recommend: (i) selection of models by using backward elimination rather than AIC or AICc, (ii) use a stringent cut-off, e.g., p = 0.0001, and (iii) conduct sensitivity analysis of results. With thoughtful application, fixed-effect codon models should provide a useful tool for large scale multi-gene analyses.

  16. Growth and foliar nitrogen concentrations of interplanted native woody legumes and pecan

    Treesearch

    J.W. Van Sambeek; Nadia E. Navarrete-Tindall; Kenneth L. Hunt

    2008-01-01

    The interplanting and underplanting of nodulated nitrogen-fixing plants in tree plantings can increase early growth and foliage nitrogen content of hardwoods, especially black walnut and pecan. Recent studies have demonstrated that some non-nodulated woody legumes may be capable of fixing significant levels of atmospheric nitrogen. The following nine nurse crop...

  17. 19 CFR 24.72 - Claims; set-off.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... CUSTOMS FINANCIAL AND ACCOUNTING PROCEDURE § 24.72 Claims; set-off. When an importer of record or other... indebted to the United States, either as principal or surety, for an amount which is legally fixed and...

  18. Improved method for extraction and detection of Helicobacter pylori DNA in formalin-fixed paraffin embedded gastric biopsies using laser micro-dissection.

    PubMed

    Loayza, María Fernanda; Villavicencio, Fernando Xavier; Santander, Stephanie Carolina; Baldeón, Manuel; Ponce, Lourdes Karina; Salvador, Iván; Vivar Díaz, Nicolás

    2015-01-01

    To assess the molecular events exerted by Helicobacter pylori interacting directly with gastric epithelial cells, an improved procedure for microbial DNA isolation from stained hematoxilin-eosin gastric biopsies was developed based on laser micro-dissection (LM) [1]. Few articles have described the use of LM to select and detect H. pylori genome from formalin-fixed paraffin embedded gastric tissue [2]. To improve the yield and quality of DNA isolated from H. pylori contacting intestinal epithelial cells, the following conditions were established after modification of the QIAamp DNA Micro kit. •Use of at least 25 cut sections of 10-20 μm of diameter and 3 μm thick with more than 10 bacteria in each cut.•Lysis with 30 μL of tissue lysis buffer and 20 μL of proteinase K (PK) with the tube in an upside-down position.•The use of thin purification columns with 35 μL of elution buffer. The mean of DNA concentration obtained from 25 LM cut sections was 1.94± 0 .16 ng/μL, and it was efficiently amplified with qPCR in a Bio Rad iCycler instrument. The LM can improve the sample selection and DNA extraction for molecular analysis of H. pylori associated with human gastric epithelium.

  19. Effects of Lugol's iodine solution and formalin on cell volume of three bloom-forming dinoflagellates

    NASA Astrophysics Data System (ADS)

    Yang, Yang; Sun, Xiaoxia; Zhao, Yongfang

    2017-07-01

    Fixatives are traditionally used in marine ecosystem research. The bias introduced by fixatives on the dimensions of plankton cells may lead to an overestimation or underestimation of the carbon biomass. To determine the impact of traditional fixatives on dinoflagellates during short- and long-term fixation, we analyzed the degree of change in three bloom-forming dinoflagellates ( Prorocentrum micans, Scrippsiella trochoidea and Noctiluca scintillans) brought about by Lugol's iodine solution (hereafter Lugol's) and formalin. The fixation effects were species-specific. P. micans cell volume showed no significant change following long-term preservation, and S. trochoidea swelled by approximately 8.06% in Lugol's and by 20.97% in formalin as a percentage of the live cell volume, respectively. N. scintillans shrank significantly in both fixatives. The volume change due to formalin in N. scintillans was not concentration-dependent, whereas the volume shrinkage of N. scintillans cells fixed with Lugol's at a concentration of 2% was nearly six-fold that in cells fixed with Lugol's at a concentration of 0.6%-0.8%. To better estimate the volume of N. scintillans fixed in formalin at a concentration of 5%, we suggest that the conversion relationship was as follows: volume of live cell=volume of intact fixed cell/0.61. Apart from size change, damage induced by fixatives on N. scintillans was obvious. Lugol's is not a suitable fixative for N. scintillans due to high frequency of broken cells. Accurate carbon biomass estimate of N. scintillans should be performed on live samples. These findings help to improve the estimate of phytoplankton cell volume and carbon biomass in marine ecosystem.

  20. Examining the effect of galaxy evolution on the stellar-halo mass relation in the EAGLE simulation

    NASA Astrophysics Data System (ADS)

    Kulier, Andrea; Padilla, Nelson; Schaye, Joop; Crain, Robert; Schaller, Matthieu; Bower, Richard; Theuns, Tom; Paillas, Enrique

    2018-01-01

    The EAGLE hydrodynamical simulation was used in Matthee et al. 2016 to examine the scatter in the stellar mass-halo mass relation of central galaxies, finding that the stellar mass (M*) correlates well with the maximum circular velocity (Vmax) of the host halo, but with a substantial scatter that does not correlate significantly with other host halo properties. Here we further examine the scatter in the stellar mass-halo mass relation of central galaxies in EAGLE, its correlation with other properties, and its origin. We find that at fixed Vmax, galaxies with lower concentration have younger stellar populations, as expected from the relationship between concentration and halo assembly time. However, at fixed Vmax and halo concentration, galaxies with larger M* have younger stellar ages, so that combining the two effects, galaxies with younger stellar ages at fixed halo mass have higher stellar masses. The host halos of galaxies with larger M* at fixed Vmax and concentration also contain more gas than those with smaller stellar masses at z = 0.1, i.e. the baryon fraction of the halos is larger. There is an even stronger correlation between the scatter in M* at z = 0.1 and the scatter in the baryon fraction of the galaxy's progenitors at z ~ 1, such that the latter sets ~50% of the scatter in M* at z = 0.1. We conclude that most of the scatter between Vmax and M* at z = 0.1 is set at earlier redshifts by the scatter in the baryon fraction of halos, which in turn is primarily the result of differences in feedback strength within halos.

  1. Fixed-bed adsorption study of methylene blue onto pyrolytic tire char

    NASA Astrophysics Data System (ADS)

    Makrigianni, Vassiliki; Giannakas, Aris; Papadaki, Maria; Albanis, Triantafyllos; Konstantinou, Ioannis

    2016-04-01

    In this work, the adsorption efficiency of acid treated pyrolytic tire char to cationic methylene blue (MB) dye adsorption from aqueous solutions was investigated by fixed-bed adsorption column experiments. The effects of the initial dye concentration (10 - 40 mg L-1) and feed flow rate (50 - 150 mL min -1) with a fixed bed height (15 cm) were studied in order to determine the breakthrough characteristics of the adsorption system. The Adams-Bohart, Yoon-Nelson and Thomas model were applied to the adsorption of MB onto char at different operational conditions to predict the breakthrough curves and to determine the characteristic parameters of the column. The results showed that the maximum adsorbed quantities decreased with increasing flow rate and increased with increasing initial MB concentration. Breakthrough time and exhaustion time increased with decreasing inlet dye concentration and flow rate. In contrast with Adams-Bohart model, Yoon-Nelson model followed by Thomas model were found more suitable to describe the fixed-bed adsorption of methylene blue by char. The correlation coefficient values R2 for both models at different operating conditions are higher than 0.9 and the low average relative error values provided very good fittings of experimental data at different operating conditions. Higher adsorption capacity of 3.85 mg g -1 was obtained at 15 cm of adsorbent bed height, flow rate of 100 mL min -1and initial MB concentration of 40 mg L-1. Although that activated carbons exhibited higher adsorption capacities in the literature, acid-treated pyrolytic tire char was found to be considerably efficient adsorbent for the removal of MB dye column taking into account the advantages of the simpler production process compared to activated carbons, as well as, the availability of waste tire feedstock and concurrent waste tire management.

  2. Batch and fixed-bed biosorption of Cd(II) from aqueous solution using immobilized Pleurotus ostreatus spent substrate.

    PubMed

    Jin, Yu; Teng, Chunying; Yu, Sumei; Song, Tao; Dong, Liying; Liang, Jinsong; Bai, Xin; Liu, Xuesheng; Hu, Xiaojing; Qu, Juanjuan

    2018-01-01

    To prevent the blockage in a continuous fix-bed system, Pleurotus Ostreatus spent substrate (POSS), a composite agricultural waste, was immobilized into granular adsorbents (IPOSS) with polymeric matrix, and used to remove Cd(II) from synthetic wastewater in batch experiment as well as in continuous fixed-bed column system. In batch experiment, higher pH, temperature and Cd(II) initial concentration were conducive to a higher biosorption capacity, and the maximum biosorption capacity reached up to 87.2 mg/g at Cd(II) initial concentration of 200 mg/L, pH 6 and 25 °C. The biosorption of Cd(II) onto IPOSS followed the Langmuir isotherm model with the maximum adsorption capacity(q max ) of 100 mg/g. The biosorption was an endothermic reaction and a spontaneous process based on positive value of ΔH 0 and negative value of ΔG 0 . In fixed-bed column system, higher bed depth, lower flow rate and influent Cd(II) concentration led to a longer breakthrough and exhaustion time, and the best performance (equilibrium uptake (q e ) of 14.4 mg, breakthrough time at 31 h and exhaustion time at 78 h) was achieved at a bed depth of 110 cm, a flow rate of 1.2 L/h and an influent concentration of 100 mg/L. Furthermore, regeneration experiment revealed a good reusability of IPOSS with 0.1 M HNO 3 as eluting agent during three cycles of adsorption and desorption. Cd(II) biosorption onto IPOSS mainly relied on a chemical process including ion exchange and complexation or coordination revealed by SEM-EDX, FTIR and XRD analysis. Copyright © 2017. Published by Elsevier Ltd.

  3. Subcellular Organization of CaMKII in Rat Hippocampal Pyramidal Neurons

    PubMed Central

    Ding, Jin-Dong; Kennedy, Mary B.; Weinberg, Richard J.

    2015-01-01

    Calcium/calmodulin-dependent protein kinase II (CaM-KII) plays a key role in N-methyl-D-aspartate (NMDA) receptor-dependent long-term synaptic plasticity; its location is critical for signal transduction, and may provide clues that further elucidate its function. We therefore examined the subcellular localization of CaMKII in CA1 stratum radiatum of adult rat hippocampus, by using immuno-electron microscopy after chemical fixation. When tissue was fixed quickly, the concentration of CaMKIIα (assessed by pre-embedding immunogold) was significantly higher in dendritic shafts than in spine heads. However, when tissue was fixed 5 minutes after perfusion with normal saline, the density of labeling decreased in dendritic shaft while increasing in spine heads, implying rapid translocation into the spine during brief perimortem stress. Likewise, in quickly fixed tissue, CaMKII within spine heads was found at comparable concentrations in the “proximal” half (adjacent to the spine neck) and the “distal” half (containing the postsynaptic density [PSD]), whereas after delayed fixation, label density increased in the distal side of the spine head, suggesting that CaMKII within the spine head moves toward the PSD during this interval. To estimate its distribution at the synapse in vivo, we performed postembedding immunogold staining for CaMKII in quick-fixed tissue, and found that the enzyme did not concentrate primarily within the central matrix of the PSD. Instead, labeling density peaked ∼40 nm inside the postsynaptic membrane, at the cytoplasmic fringe of the PSD. Labeling within 25 nm of the postsynaptic membrane concentrated at the lateral edge of the synapse. This lateral “PSD core” pool of CaMKII may play a special role in synaptic plasticity. PMID:23749614

  4. Immediate loading with fixed full-arch prostheses in the maxilla: Review of the literature

    PubMed Central

    Peñarrocha-Oltra, David; Covani, Ugo; Peñarrocha-Diago, Miguel

    2014-01-01

    Objectives: To critically review the evidence-based literature on immediate loading of implants with fixed full-arch prostheses in the maxilla to determine 1) currently recommended performance criteria and 2) the outcomes that can be expected with this procedure. Study Desing: Studies from 2001 to 2011 on immediate loading with fixed full-arch maxillary prostheses were reviewed. Clinical series with at least 5 patients and 12 months of follow-up were included. Case reports, studies with missing data and repeatedly published studies were excluded. In each study the following was assessed: type of study, implant type, number of patients, number of implants, number of implants per patient, use of post-extraction implants, minimum implant length and diameter, type of prosthesis, time until loading, implant survival rate, prosthesis survival rate, marginal bone loss, complications andmean follow-up time. Criteria for patient selection, implant primary stability and bone regeneration were also studied. Results: Thirteen studies were included, reporting a total of 2484 immediately loaded implants in 365 patients. Currently accepted performance criteria regarding patient and implant selection, and surgical and prosthetic procedures were deduced from the reviewed articles. Implant survival rates went from 87.5% to 100%, prosthesis survival rates from 93.8% to 100% and radiographic marginal bone loss from 0.8 mm to 1.6 mm.No intraoperative complications and only minor prosthetic complications were reported. Conclusions: The literature on immediate loading with fixed full-arch prostheses in the maxilla shows that a successful outcome can be expected if adequate criteria are used to evaluate the patient, choose the implant and perform the surgical and prosthetic treatment. Lack of homogeneity within studies limits the relevance of the conclusions that can be drawn, and more controlled randomized studies are necessary to enable comparison between the immediate and the conventional loading procedures. Key words:Immediate loading, full-arch, dental implants, loading protocols. PMID:24880445

  5. Fixed 50:50 mixture of nitrous oxide and oxygen to reduce lumbar-puncture-induced pain: a randomized controlled trial.

    PubMed

    Moisset, X; Sia, M A; Pereira, B; Taithe, F; Dumont, E; Bernard, L; Clavelou, P

    2017-01-01

    Lumbar puncture (LP) has been frequently performed for more than a century. This procedure is still stressful and often painful. The aim of the study was to evaluate the efficacy of a fixed 50% nitrous oxide-oxygen mixture compared to placebo to reduce immediate procedural pain and anxiety during LP. A randomized controlled trial was conducted involving adults who needed a cerebrospinal fluid analysis. Patients were randomly assigned to inhale either a fixed 50% nitrous oxide-oxygen mixture (50% N 2 O-O 2 ) or medical air (22% O 2 -78% N 2 ). Cutaneous application of a eutectic mixture of local anaesthetics was systematically done and all LPs were performed with pencil point 25G needles (20G introducer needle). The primary end-point was the maximal pain level felt by the patient during the procedure, the maximal anxiety level being a secondary outcome, both measured using a numerical rating scale (0-10). A total of 66 consecutive patients were randomized. The analysis was intention to treat. The maximal pain was 4.9 ± 2.7 for the 33 patients receiving air and 2.7 ± 2.7 for the 33 receiving 50% N 2 O-O 2 (P = 0.002). Similarly, the maximal LP-induced anxiety was 4.5 ± 3.1 vs. 2.6 ± 2.6 (P = 0.009), respectively. The number needed to treat to avoid one patient undergoing significant pain (pain score ≥ 4/10) was 2.75. Body mass index >25 kg/m 2 was significantly associated with higher pain intensity (P = 0.03). No serious adverse events were attributable to 50% N 2 O-O 2 inhalation. Inhalation of a fixed 50% N 2 O-O 2 mixture is efficient to reduce LP-induced pain and anxiety. © 2016 EAN.

  6. The Dynamics of Natural Climatic Change

    DTIC Science & Technology

    1975-07-17

    moraines which fix the position of ancient ice bodies to studies of fossil pol- len and plankton which provide panoramas of past continents and oceans... thermal and salinity estimates show a high positive correlation at mid- and high-latitude sites in the North Atlantic during the past 130,000 years...the thermal effect, these authors outline an alternate procedure for obtaining temperature estimates. When this alternat.i -e procedure was

  7. Multispectral and DSLR sensors for assessing crop stress in corn and cotton using fixed-wing unmanned air systems

    NASA Astrophysics Data System (ADS)

    Valasek, John; Henrickson, James V.; Bowden, Ezekiel; Shi, Yeyin; Morgan, Cristine L. S.; Neely, Haly L.

    2016-05-01

    As small unmanned aircraft systems become increasingly affordable, reliable, and formally recognized under federal regulation, they become increasingly attractive as novel platforms for civil applications. This paper details the development and demonstration of fixed-wing unmanned aircraft systems for precision agriculture tasks. Tasks such as soil moisture content and high throughput phenotyping are considered. Rationale for sensor, vehicle, and ground equipment selections are provided, in addition to developed flight operation procedures for minimal numbers of crew. Preliminary imagery results are presented and analyzed, and these results demonstrate that fixed-wing unmanned aircraft systems modified to carry non-traditional sensors at extended endurance durations can provide high quality data that is usable for serious scientific analysis.

  8. Comparative toxicity of silver nanoparticles and silver ions to Escherichia coli.

    PubMed

    Choi, Yoojin; Kim, Hyun-A; Kim, Kyoung-Woong; Lee, Byung-Tae

    2018-04-01

    With the increase in silver (Ag)-based products in our lives, it is essential to test the potential toxicity of silver nanoparticles (AgNPs) and silver ions (Ag ions) on living organisms under various conditions. Here, we investigated the toxicity of AgNPs with Ag ions to Escherichia coli K-12 strain under various conditions. We observed that both AgNPs and Ag ions display antibacterial activities, and that Ag ions had higher toxicity to E. coli K-12 strain than AgNPs under the same concentrations. To understand the toxicity of AgNPs at a cellular level, reactive oxygen species (ROS) enzymes were detected for use as antioxidant enzymatic biomarkers. We have also studied the toxicity of AgNPs and Ag ions under various coexistence conditions including: fixed total concentration, with a varied the ratio of AgNPs to Ag ions; fixed the AgNPs concentration and then increased the Ag ions concentration; fixed Ag ions concentration and then increasing the AgNPs concentration. Exposure to AgNPs and Ag ions clearly had synergistic toxicity; however, decreased toxicity (for a fixed AgNPs concentration of 5mg/L, after increasing the Ag ions concentration) to E. coli K-12 strain. AgNPs and Ag ions in the presence of L-cysteine accelerated the bacterial cell growth rate, thereby reducing the bioavailability of Ag ions released from AgNPs under the single and coexistence conditions. Further works are needed to consider this potential for AgNPs and Ag ions toxicity across a range of environmental conditions. As silver nanoparticles (AgNPs)-based products are being broadly used in commercial industries, an ecotoxicological understanding of the AgNPs being released into the environment should be further considered. Here, we investigate the comparative toxicity of AgNPs and silver ions (Ag ions) to Escherichia coli K-12 strain, a representative ecotoxicological bioreporter. This study showed that toxicities of AgNPs and Ag ions to E. coli K-12 strain display different relationships when existing individually or when coexisting, and in the presence of L-cysteine materials. These findings suggest that the toxicology research of nanomaterials should consider conditions when NPs coexist with and without their bioavailable ions. Copyright © 2017. Published by Elsevier B.V.

  9. Adaptive clustering procedure for continuous gravitational wave searches

    NASA Astrophysics Data System (ADS)

    Singh, Avneet; Papa, Maria Alessandra; Eggenstein, Heinz-Bernd; Walsh, Sinéad

    2017-10-01

    In hierarchical searches for continuous gravitational waves, clustering of candidates is an important post-processing step because it reduces the number of noise candidates that are followed up at successive stages [J. Aasi et al., Phys. Rev. Lett. 88, 102002 (2013), 10.1103/PhysRevD.88.102002; B. Behnke, M. A. Papa, and R. Prix, Phys. Rev. D 91, 064007 (2015), 10.1103/PhysRevD.91.064007; M. A. Papa et al., Phys. Rev. D 94, 122006 (2016), 10.1103/PhysRevD.94.122006]. Previous clustering procedures bundled together nearby candidates ascribing them to the same root cause (be it a signal or a disturbance), based on a predefined cluster volume. In this paper, we present a procedure that adapts the cluster volume to the data itself and checks for consistency of such volume with what is expected from a signal. This significantly improves the noise rejection capabilities at fixed detection threshold, and at fixed computing resources for the follow-up stages, this results in an overall more sensitive search. This new procedure was employed in the first Einstein@Home search on data from the first science run of the advanced LIGO detectors (O1) [LIGO Scientific Collaboration and Virgo Collaboration, arXiv:1707.02669 [Phys. Rev. D (to be published)

  10. Cocaine versus food choice procedure in rats: environmental manipulations and effects of amphetamine.

    PubMed

    Thomsen, Morgane; Barrett, Andrew C; Negus, S Stevens; Caine, S Barak

    2013-03-01

    We have adapted a nonhuman primate model of cocaine versus food choice to the rat species. To evaluate the procedure, we tested cocaine versus food choice under a variety of environmental manipulations as well as pharmacological pretreatments. Complete cocaine-choice dose-effect curves (0-1.0 mg/kg/infusion) were obtained for each condition under concurrent fixed ratio schedules of reinforcement. Percentage of responding emitted on the cocaine-reinforced lever was not affected significantly by removal of cocaine-associated visual or auditory cues, but it was decreased after removal of response-contingent or response-independent cocaine infusions. Cocaine choice was sensitive to the magnitude and fixed ratio requirement of both the cocaine and food reinforcers. We also tested the effects of acute (0.32, 0.56, 1.0, 1.8 mg/kg) and chronic (0.1, 0.32 mg/kg/hr) d-amphetamine treatment on cocaine choice. Acute and chronic d-amphetamine had opposite effects, with acute increasing and chronic decreasing cocaine choice, similar to observations in humans and in nonhuman primates. The results suggest feasibility and utility of the choice procedure in rats and support its comparability to similar procedures used in humans and monkeys. © Society for the Experimental Analysis of Behavior.

  11. Optimization for minimum sensitivity to uncertain parameters

    NASA Technical Reports Server (NTRS)

    Pritchard, Jocelyn I.; Adelman, Howard M.; Sobieszczanski-Sobieski, Jaroslaw

    1994-01-01

    A procedure to design a structure for minimum sensitivity to uncertainties in problem parameters is described. The approach is to minimize directly the sensitivity derivatives of the optimum design with respect to fixed design parameters using a nested optimization procedure. The procedure is demonstrated for the design of a bimetallic beam for minimum weight with insensitivity to uncertainties in structural properties. The beam is modeled with finite elements based on two dimensional beam analysis. A sequential quadratic programming procedure used as the optimizer supplies the Lagrange multipliers that are used to calculate the optimum sensitivity derivatives. The method was perceived to be successful from comparisons of the optimization results with parametric studies.

  12. Clinical and Analytical Evaluation of a Single-Vial Stool Collection Device with Formalin-Free Fixative for Improved Processing and Comprehensive Detection of Gastrointestinal Parasites

    PubMed Central

    Couturier, Brianne A.; Jensen, Ryan; Arias, Nora; Heffron, Michael; Gubler, Elyse; Case, Kristin; Gowans, Jason

    2015-01-01

    Microscopic examination of feces is a standard laboratory method for diagnosing gastrointestinal parasite infections. In North America, the ovum and parasite (O&P) examination is typically performed using stool that is chemically fixed in polyvinyl alcohol (PVA) and formalin, after which the stool is concentrated by filtration to enhance sensitivity. Mini Parasep solvent-free (SF) tubes allow collection and concentration within a single collection vial. The goal of the study was to determine whether consolidated processing and concentration with the Parasep tubes using an alcohol-based fixative (Alcorfix) provide O&P examinations equivalent to or better than those done by processing of PVA-formalin-fixed stool using a SpinCon concentration device. Parasep tubes revealed filtration performance equivalent to that of the SpinCon concentration device using PVA-formalin-fixed stool containing protozoa. Specimens cocollected in Parasep tubes containing PVA-formalin and Alcorfix revealed comparable morphology and staining for various protozoa. Alcorfix effectively fixed live Cryptosporidium and microsporidia such that morphology and staining were conserved for modified acid-fast and modified trichrome stains. A work flow analysis revealed significant time savings for batches of 10 or 30 O&P specimens in tubes with Alcorfix compared to the amount of time that it took to analyze the same number of specimens in tubes with PVA-formalin. The direct hands-on time savings with Mini Parasep tubes were 17 min and 41 s and 32 min and 1 s for batches of 10 and 30 specimens, respectively. Parasep tubes containing Alcorfix provide significant work flow advantages to laboratories that process medium to high volumes of O&P specimens by streamlining processing and converting to a single tube. These improvements in work flow, reduction of the amount of formalin used in the laboratory, and equivalent microscopy results are attractive advancements in O&P testing for North American diagnostic parasitology laboratories. PMID:26019199

  13. Clinical and Analytical Evaluation of a Single-Vial Stool Collection Device with Formalin-Free Fixative for Improved Processing and Comprehensive Detection of Gastrointestinal Parasites.

    PubMed

    Couturier, Brianne A; Jensen, Ryan; Arias, Nora; Heffron, Michael; Gubler, Elyse; Case, Kristin; Gowans, Jason; Couturier, Marc Roger

    2015-08-01

    Microscopic examination of feces is a standard laboratory method for diagnosing gastrointestinal parasite infections. In North America, the ovum and parasite (O&P) examination is typically performed using stool that is chemically fixed in polyvinyl alcohol (PVA) and formalin, after which the stool is concentrated by filtration to enhance sensitivity. Mini Parasep solvent-free (SF) tubes allow collection and concentration within a single collection vial. The goal of the study was to determine whether consolidated processing and concentration with the Parasep tubes using an alcohol-based fixative (Alcorfix) provide O&P examinations equivalent to or better than those done by processing of PVA-formalin-fixed stool using a SpinCon concentration device. Parasep tubes revealed filtration performance equivalent to that of the SpinCon concentration device using PVA-formalin-fixed stool containing protozoa. Specimens cocollected in Parasep tubes containing PVA-formalin and Alcorfix revealed comparable morphology and staining for various protozoa. Alcorfix effectively fixed live Cryptosporidium and microsporidia such that morphology and staining were conserved for modified acid-fast and modified trichrome stains. A work flow analysis revealed significant time savings for batches of 10 or 30 O&P specimens in tubes with Alcorfix compared to the amount of time that it took to analyze the same number of specimens in tubes with PVA-formalin. The direct hands-on time savings with Mini Parasep tubes were 17 min and 41 s and 32 min and 1 s for batches of 10 and 30 specimens, respectively. Parasep tubes containing Alcorfix provide significant work flow advantages to laboratories that process medium to high volumes of O&P specimens by streamlining processing and converting to a single tube. These improvements in work flow, reduction of the amount of formalin used in the laboratory, and equivalent microscopy results are attractive advancements in O&P testing for North American diagnostic parasitology laboratories. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  14. [Perioperative complications after total hip revision surgery and their predictive factors. A series of 181 consecutive procedures].

    PubMed

    de Thomasson, E; Guingand, O; Terracher, R; Mazel, C

    2001-09-01

    We conducted a retrospective study to assess morbidity and mortality in patients undergoing revision total hip arthroplasty (THA) procedures. Perioperative complications were recorded in 181 revision procedures (162 patients) performed between January 1995 and March 1999 (117 bipolar revisions and 64 acetabular isolated revisions). There were 86 complications (68 patients) leading to 21 new revisions. About half (50/86) were related to the surgical procedure (dislocation, femoral fracture, infection.). Life-threatening complications (3.6%) ended in patient death in 1.6% of the cases. Complications were more frequent in patients with an ASA score=3 (p<0.01) or aged over 75 years (p<0.05). Age was also predictive of femoral misalignment and fracture (p<0.05). Dislocations (8.8%) were observed more frequently in patients who had undergone more than 2 procedures prior to the revision (p<0.05) (4.8% of the dislocations in patients undergoing a first revision procedure and 14.3% in the others). In addition, peroperative blood loss and duration of the procedure were significantly greater in case of bipolar replacement than for isolated acetabular replacement (sigma > 1.96). Our experience and data in the literature point to the important age factor in the development of complications. Preservation of a well-fixed femoral component does not appear to worsen prognosis and leads to fewer complications than bipolar changes. The decision to revise a THA must take into consideration the functional impairment but also the risks inherent in revision procedures, particularly in old patients who have undergone several procedures. Revising the acetabular component alone can be an interesting option if the femoral component remains well-fixed although our follow-up is insufficient to determine whether this attitude provides better long-term outcome than complete biopolar revision. Better patient selection and improved operative technique, in particular in femur preparation, should help reduce morbidity and mortality in this type of procedure.

  15. AAV liver expression of FIX-Padua prevents and eradicates FIX inhibitor without increasing thrombogenicity in hemophilia B dogs and mice.

    PubMed

    Crudele, Julie M; Finn, Jonathan D; Siner, Joshua I; Martin, Nicholas B; Niemeyer, Glenn P; Zhou, Shangzhen; Mingozzi, Federico; Lothrop, Clinton D; Arruda, Valder R

    2015-03-05

    Emerging successful clinical data on gene therapy using adeno-associated viral (AAV) vector for hemophilia B (HB) showed that the risk of cellular immune response to vector capsid is clearly dose dependent. To decrease the vector dose, we explored AAV-8 (1-3 × 10(12) vg/kg) encoding a hyperfunctional factor IX (FIX-Padua, arginine 338 to leucine) in FIX inhibitor-prone HB dogs. Two naïve HB dogs showed sustained expression of FIX-Padua with an 8- to 12-fold increased specific activity reaching 25% to 40% activity without antibody formation to FIX. A third dog with preexisting FIX inhibitors exhibited a transient anamnestic response (5 Bethesda units) at 2 weeks after vector delivery following by spontaneous eradication of the antibody to FIX by day 70. In this dog, sustained FIX expression reached ∼200% and 30% of activity and antigen levels, respectively. Immune tolerance was confirmed in all dogs after challenges with plasma-derived FIX concentrate. Shortening of the clotting times and lack of bleeding episodes support the phenotypic correction of the severe phenotype, with no clinical or laboratory evidence of risk of thrombosis. Provocative studies in mice showed that FIX-Padua exhibits similar immunogenicity and thrombogenicity compared with FIX wild type. Collectively, these data support the potential translation of gene-based strategies using FIX-Padua for HB. © 2015 by The American Society of Hematology.

  16. Safety and efficacy of Cardi-O-fix occluder for percutaneous closure of a patent foramen ovale

    PubMed Central

    Zhao, Enfa; Liu, Wenjuan; Zhang, Yushun; Cheng, Gesheng; Du, Yajuan; He, Lu; Wang, Xingye; He, Xumei

    2017-01-01

    Abstract Background: Amplatzer occluder and Cardio-O-fix occluder are currently used in percutaneous closure of patent foramen ovale. However, there is still a lack of relevant reports comparison the differences between them. The aim of this study was to evaluate the short-term and mid-term safety and efficacy of the Cardi-O-fix occluder in preventing recurrent cerebrovascular events in patients with a patent foramen ovale (PFO). Methods: We enrolled 246 patients (105 men) with a PFO from May 30, 2013 to March 30, 2015 in this single-center prospective study. All patients were treated by PFO interventional closure, with the Cardi-O-fix PFO occluder being used in 180 patients and the Amplatzer PFO occluder being utilized in the remaining 66 patients. After the procedure, we verified the safety and efficacy of different devices using contrast transthoracic echocardiography. Results: Neither recurrent stroke nor death was encountered during the follow-up of 12 months. Transient ischemic attack (TIA) was noted in 2 patients (1.1%) in the Cardi-O-fix PFO occluder group, and 1 patient suffered from TIA (1.5%) in the Amplatzer PFO occluder group. Among them, only 1 patient exhibited a small right to left shunt (RLS). There was no statistical difference in recurrent cerebral ischemic events. Three cases of paroxysmal atrial fibrillation were observed in the Cardi-O-fix PFO occluder group. One reverted spontaneously to sinus rhythm and the other 2 cases had pharmacologic conversion to sinus rhythm. One case of paroxysmal atrial fibrillation occurred in the Amplatzer group, which underwent pharmacologic conversion to sinus rhythm. There was no significant difference between the 2 groups regarding incidence of arrhythmia. No occluder translocation, erosion, pericardial effusion, and puncture site bleeding were observed in the 2 groups within 12 months of follow-up. The complete closure rates of the Cardi-O-fix and Amplatzer PFO occluder devices at the 12 months after the procedure were 73.9% and 63.6%, respectively, and the effective closure rates were 90.6% and 86.4%, respectively. There was no statistically significant difference in the complete closure rate and effective occlusion rate (P > 0.05) between the devices. Conclusions: There was no significant difference in the short- and mid-term efficacy and safety between the Cardi-O-fix PFO occluder and Amplatzer PFO occluder. The efficacy and safety of the Cardi-O-fix occluder were comparable to those of the Amplatzer PFO occluder. PMID:28383438

  17. Design and FPGA Implementation of a Universal Chaotic Signal Generator Based on the Verilog HDL Fixed-Point Algorithm and State Machine Control

    NASA Astrophysics Data System (ADS)

    Qiu, Mo; Yu, Simin; Wen, Yuqiong; Lü, Jinhu; He, Jianbin; Lin, Zhuosheng

    In this paper, a novel design methodology and its FPGA hardware implementation for a universal chaotic signal generator is proposed via the Verilog HDL fixed-point algorithm and state machine control. According to continuous-time or discrete-time chaotic equations, a Verilog HDL fixed-point algorithm and its corresponding digital system are first designed. In the FPGA hardware platform, each operation step of Verilog HDL fixed-point algorithm is then controlled by a state machine. The generality of this method is that, for any given chaotic equation, it can be decomposed into four basic operation procedures, i.e. nonlinear function calculation, iterative sequence operation, iterative values right shifting and ceiling, and chaotic iterative sequences output, each of which corresponds to only a state via state machine control. Compared with the Verilog HDL floating-point algorithm, the Verilog HDL fixed-point algorithm can save the FPGA hardware resources and improve the operation efficiency. FPGA-based hardware experimental results validate the feasibility and reliability of the proposed approach.

  18. Long-Term Stability of Inorganic, Methyl and Ethyl Mercury in Whole Blood: Effects of Storage Temperature and Time

    PubMed Central

    Sommer, Yuliya L.; Ward, Cynthia D.; Pan, Yi; Caldwell, Kathleen L.; Jones, Robert L.

    2016-01-01

    In this study, we evaluated the effect of temperature on the long-term stability of three mercury species in bovine blood. We used inductively coupled plasma mass spectrometry (ICP-MS) analysis to determine the concentrations of inorganic (iHg), methyl (MeHg) and ethyl (EtHg) mercury species in two blood pools stored at temperatures of −70, −20, 4, 23°C (room temperature) and 37°C. Over the course of a year, we analyzed aliquots of pooled specimens at time intervals of 1, 2, 4 and 6 weeks and 2, 4, 6, 8, 10 and 12 months. We applied a fixed-effects linear model, step-down pairwise comparison and coefficient of variation statistical analysis to examine the temperature and time effects on changes in mercury species concentrations. We observed several instances of statistically significant differences in mercury species concentrations between different temperatures and time points; however, with considerations of experimental factors (such as instrumental drift and sample preparation procedures), not all differences were scientifically important. We concluded that iHg, MeHg and EtHg species in bovine whole blood were stable at −70, −20, 4 and 23°C for 1 year, but blood samples stored at 37°C were stable for no more than 2 weeks. PMID:26912563

  19. Microwave irradiation decreases ATP, increases free [Mg2+], and alters in vivo intracellular reactions in rat brain

    PubMed Central

    Srivastava, Shireesh; Kashiwaya, Yoshihiro; Chen, Xuesong; Geiger, Jonathan D.; Pawlosky, Robert; Veech, Richard L.

    2012-01-01

    Rapid inactivation of metabolism is essential for accurately determining the concentrations of metabolic intermediates in the in vivo state. We compared a broad spectrum of energetic intermediate metabolites and neurotransmitters in brains obtained by microwave irradiation to those obtained by freeze blowing, the most rapid method of extracting and freezing rat brain. The concentrations of many intermediates, cytosolic free NAD(P)+/NAD(P)H ratios, as well as neurotransmitters were not affected by the microwave procedure. However, the brain concentrations of ATP were about 30% lower, whereas those of ADP, AMP, and GDP were higher in the microwave-irradiated compared with the freeze-blown brains. In addition, the hydrolysis of approximately 1 μmol/g of ATP, a major in vivo Mg2+-binding site, was related to approximately five-fold increase in free [Mg2+] (0.53 ± 0.07 mM in freeze blown vs. 2.91 mM ± 0.48 mM in microwaved brains), as determined from the ratio [citrate]/[isocitrate]. Consequently, many intracellular properties, such as the phosphorylation potential and the ΔG’ of ATP hydrolysis were significantly altered in microwaved tissue. The determinations of some glycolytic and TCA cycle metabolites, the phosphorylation potential, and the ΔG’ of ATP hydrolysis do not represent the in vivo state when using microwave-fixed brain tissue. PMID:23013291

  20. 10 CFR 73.46 - Fixed site physical protection systems, subsystems, components, and procedures.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... week, maintaining an intensity of approximately 75 percent of maximum heart rate for 20 minutes; (B... television or by other suitable means which limit exposure of responding personnel to possible attack. (7...

  1. 49 CFR 1562.25 - Fixed base operator requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 1562.25 Transportation Other Regulations Relating to Transportation (Continued) TRANSPORTATION SECURITY ADMINISTRATION, DEPARTMENT OF HOMELAND SECURITY CIVIL AVIATION SECURITY OPERATIONS IN THE WASHINGTON, DC, METROPOLITAN AREA Ronald Reagan Washington National Airport: Enhanced Security Procedures for Certain...

  2. Synframe: a preliminary report.

    PubMed

    Aebi, M; Steffen, T

    2000-02-01

    Both endoscopic lumbar spinal surgery and the non-standardized and unstable retractor systems for the lumbar spine presently on the market have disadvantages and limitations in relation to the minimally invasive surgical concept, which have been gradually recognized in the last few years. In an attempt to resolve some of these issues, we have developed a highly versatile retractor system, which allows access to and surgery at the lumbar, thoracic and even cervical spine. This retractor system - Synframe - is based on a ring concept allowing 360 degrees access to a surgical opening in anterior as well as posterior surgery. The ring is concentrically laid over the surgical opening for the approach and is used as a carrier for retractor arms, which are instrumented with either different sizes or types of blades and/or different sizes of Hohmann hooks. In posterior surgery, nerve root retractors can also be installed. This ring also functions as a carrier for fiberoptic illumination devices and different sizes of endoscopes, used to transmit the surgical procedure out of the depth of the surgical exposure for both teaching purposes and for the surgical team when it has no longer direct visual access to the procedure. The ring is stable, being fixed onto the operating table, allowing precise minimally open approaches and surgical procedures under direct vision with optimal illumination. This ring system also opens perspectives for an integrated minimally open surgical concept, where the ring may be used as a reference platform in computer-navigated surgery.

  3. Vital pulp therapy with bipolar electrocoagulation after intentional pulp exposure of fixed prosthodontic abutments: a clinical report.

    PubMed

    Livaditis, G J

    2001-10-01

    A clinical protocol is described for the treatment of intentional and unavoidable exposed pulps during crown preparation. The protocol includes a definitive cavity preparation to create space in the exposed dentin for an adhesive pulp barrier; procedures to develop the highly desirable hybrid zone to prevent microleakage; the use of a specific resinous material that serves as a long-term pulp barrier with a relatively neutral and biocompatible impact on the pulp; and the use of precise bipolar electrocoagulation to provide durable hemostasis for restoration of the pulp wall and a relatively clot-free surgical wound to facilitate healing. The protocol involves the application of gentle surgical and restorative procedures to support the inherent healing process to restore the health of the pulp. The patient presented was part of a larger investigation and was selected in an attempt to identify a fixed prosthodontic application of the proposed pulp therapy protocol.

  4. Long-term imaging in awake mice using removable cranial windows

    PubMed Central

    Glickfeld, Lindsey L.; Kerlin, Aaron M.; Reid, R. Clay; Bonin, Vincent; Schafer, Dorothy P.; Andermann, Mark L.

    2015-01-01

    Cranial window implants in head-fixed rodents are becoming a preparation of choice for stable optical access to large areas of cortex over extended periods of time. Here, we provide a highly detailed and reliable surgical protocol for a cranial window implantation procedure for chronic widefield and cellular imaging in awake, head-fixed mice, which enables subsequent window removal and replacement in the weeks and months following the initial craniotomy. This protocol has facilitated awake, chronic imaging in adolescent as well as adult mice over several months from a large number of cortical brain regions; targeted virus and tracer injections from data obtained using prior awake functional mapping; and functionally-targeted two-photon imaging across all cortical layers in awake mice using a microprism attachment to the cranial window. Collectively, these procedures extend the reach of chronic imaging of cortical function and dysfunction in behaving animals. PMID:25275789

  5. Dielectric compound parabolic concentrating solar collector with frustrated total internal reflection absorber

    NASA Astrophysics Data System (ADS)

    Hull, J. R.

    Since its introduction, the concept of nonimaging solar concentrators, as exemplified by the compound parabolic concentrator (CPC) design, has greatly enhanced the ability to collect solar energy efficiently in thermal and photovoltaic devices. When used as a primary concentrator, a CPC can provide significant concentration without the complication of a tracking mechanism and its associated maintenance problems. When used as a secondary, a CPC provides higher total concentration, or for a fixed concentration, tolerates greater tracking error in the primary.

  6. Fixed solar concentrator-collector-satelite receiver and co-generator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meckler, M.

    1985-01-01

    An insolation and micro wave receiver fixedly installed in alignment with the suns azimuth and within the look angle of a satellite, and comprised of holographic windows recorded according to time related to the suns position as zone plates to concentrate infrared light into a Rankine cycle power generating receiver and to columnate ultraviolet light onto a photo voltaic power generating plane, utilizing a micro wave dish as the substrate support of photo voltaic cells and as a condenser of the Rankine cycle operating an induction generator synchronous with an external alternating current power system, and with the photo voltaicmore » power synchronized therewith by commutation.« less

  7. First analysis of 10-year trends in national factor concentrates usage in haemophilia: data from CHARMS, the Canadian Hemophilia Assessment and Resource Management System.

    PubMed

    Traore, A N; Chan, A K C; Webert, K E; Heddle, N; Ritchie, B; St-Louis, J; Teitel, J; Lillicrap, D; Iorio, A; Walker, I

    2014-07-01

    The Canadian Hemophilia Assessment and Resource Management System (CHARMS) tracks factor concentrates (FC) from the sole suppliers, Canadian Blood Services (CBS) and Hema-Quebec (HQ), to hospitals and to patients' homes. Patients FC infusion data are entered into CHARMS at Canadian Hemophilia Treatment Centres (HTCs) then exported to the national database (CentrePoint). From 2000 to 2009, 2260 registered haemophilia A or B patients received FVIII (1,009,097,765 IU) and FIX (272,406,859 IU). Over 91% of FVIII and over 84% of FIX was infused at home. Utilization of FVIII progressively increased; this was accounted for by an increase in the number of patients treated (r = 0.97; P < 0.001), there being a linear relationship between the increase in utilization and the increase in number of patients treated (P < 0.001). There was also a correlation with the annual amount used per patient (r = 0.95; P < 0.001). Utilization of FIX did not increase over time. The highest proportional utilization of both FVIII and FIX was for prophylaxis, and this proportion progressively increased being, in year 10 (2009), 77% and 66% for FVIII and FIX respectively. The proportion used for bleeding remained steady; in year 10 that proportion was 14% for FVIII and 26% for FIX, the use per patient for bleeding decreasing. The HTC-based CHARMS tracking system is essential, in Canada, for analysing indications for infusion, for predicting utilization and planning for future needs. © 2014 The Authors. Haemophilia Published by John Wiley & Sons Ltd.

  8. First analysis of 10-year trends in national factor concentrates usage in haemophilia: data from CHARMS, the Canadian Hemophilia Assessment and Resource Management System

    PubMed Central

    Traore, A N; Chan, A K C; Webert, K E; Heddle, N; Ritchie, B; St-Louis, J; Teitel, J; Lillicrap, D; Iorio, A; Walker, I

    2014-01-01

    The Canadian Hemophilia Assessment and Resource Management System (CHARMS) tracks factor concentrates (FC) from the sole suppliers, Canadian Blood Services (CBS) and Hema-Quebec (HQ), to hospitals and to patients’ homes. Patients FC infusion data are entered into CHARMS at Canadian Hemophilia Treatment Centres (HTCs) then exported to the national database (CentrePoint). From 2000 to 2009, 2260 registered haemophilia A or B patients received FVIII (1 009 097 765 IU) and FIX (272 406 859 IU). Over 91% of FVIII and over 84% of FIX was infused at home. Utilization of FVIII progressively increased; this was accounted for by an increase in the number of patients treated (r = 0.97; P < 0.001), there being a linear relationship between the increase in utilization and the increase in number of patients treated (P < 0.001). There was also a correlation with the annual amount used per patient (r = 0.95; P < 0.001). Utilization of FIX did not increase over time. The highest proportional utilization of both FVIII and FIX was for prophylaxis, and this proportion progressively increased being, in year 10 (2009), 77% and 66% for FVIII and FIX respectively. The proportion used for bleeding remained steady; in year 10 that proportion was 14% for FVIII and 26% for FIX, the use per patient for bleeding decreasing. The HTC-based CHARMS tracking system is essential, in Canada, for analysing indications for infusion, for predicting utilization and planning for future needs. PMID:24948405

  9. Exposure to dust and particle-associated 1-nitropyrene of drivers of diesel-powered equipment in underground mining.

    PubMed

    Scheepers, P T J; Micka, V; Muzyka, V; Anzion, R; Dahmann, D; Poole, J; Bos, R P

    2003-07-01

    A field study was conducted in two mines in order to determine the most suitable strategy for ambient exposure assessment in the framework of a European study aimed at validation of biological monitoring approaches for diesel exhaust (BIOMODEM). Exposure to dust and particle-associated 1-nitropyrene (1-NP) was studied in 20 miners of black coal by the long wall method (Czech Republic) and in 20 workers in oil shale mining by the room and pillar method (Estonia). The study in the oil shale mine was extended to include 100 workers in a second phase (main study). In each mine half of the study population worked underground as drivers of diesel-powered trains (black coal) and excavators (oil shale). The other half consisted of workers occupied in various non-diesel production assignments. Exposure to diesel exhaust was studied by measurement of inhalable and respirable dust at fixed locations and by personal air sampling of respirable dust. The ratio of geometric mean inhalable to respirable dust concentration was approximately two to one. The underground/surface ratio of respirable dust concentrations measured at fixed locations and in the breathing zones of the workers was 2-fold or greater. Respirable dust was 2- to 3-fold higher in the breathing zone than at fixed sampling locations. The 1-NP content in these dust fractions was determined by gas chromatography-mass spectrometry/mass spectrometry and ranged from 0.003 to 42.2 ng/m(3) in the breathing zones of the workers. In mine dust no 1-NP was detected. In both mines 1-NP was observed to be primarily associated with respirable particles. The 1-NP concentrations were also higher underground than on the surface (2- to 3-fold in the coal mine and 10-fold or more in the oil shale mine). Concentrations of 1-NP in the breathing zones were also higher than at fixed sites (2.5-fold in the coal mine and 10-fold in the oil shale mine). For individual exposure assessment personal air sampling is preferred over air sampling at fixed sites. This study also suggests that particle-associated 1-NP much better reflects the ambient exposure to diesel exhaust particles than dust concentrations. Therefore, measurement of particle-associated 1-NP is preferred over measurement of dust concentrations by gravimetry, when linking ambient exposure to biomonitoring outcomes such as protein and DNA adducts and excretion of urinary metabolites of genotoxic substances.

  10. Polymer-surfactant complex formation and its effect on turbulent wall shear stress.

    PubMed

    Suksamranchit, Siriluck; Sirivat, Anuvat; Jamieson, Alexander M

    2006-02-01

    Turbulent drag reduction in Couette flow was investigated in terms of a decrease in wall shear stress for aqueous solutions of a nonionic polymer, poly(ethylene oxide) (PEO), a cationic surfactant, hexadecyltrimethylammonium chloride (HTAC), and their mixtures. Consistent with literature data, drag reduction was observed for PEO solutions above a critical molecular weight, 0.91 x 10(5) < Mc < 3.04 x 10(5) g/mol. Maximum drag reduction occurred at an optimum concentration, c(PEO)*, which scales inversely with molecular weight, and the % maximum drag reduction increases with molecular weight. For aqueous HTAC solutions, wall shear stress decreased with increasing HTAC concentration and leveled off at an optimum concentration, c(HTAC)*, comparable to the critical micelle concentration. For HTAC/PEO mixtures, the critical PEO molecular weight for drag reduction decreases, interpreted as due to an increase in hydrodynamic volume because of binding of HTAC micelles to PEO. Consistent with this interpretation, at fixed PEO concentration, maximum drag reduction was observed at an optimum HTAC concentration, c(HTAC/PEO)*, comparable to the maximum binding concentration, MBC. Also, with HTAC concentration fixed at the MBC, the optimum PEO concentration for drag reduction, c(PEO/HTAC)*, decreases relative to that, c(PEO)*, in the absence of HTAC.

  11. [Costing nuclear medicine diagnostic procedures].

    PubMed

    Markou, Pavlos

    2005-01-01

    To the Editor: Referring to a recent special report about the cost analysis of twenty-nine nuclear medicine procedures, I would like to clarify some basic aspects for determining costs of nuclear medicine procedure with various costing methodologies. Activity Based Costing (ABC) method, is a new approach in imaging services costing that can provide the most accurate cost data, but is difficult to perform in nuclear medicine diagnostic procedures. That is because ABC requires determining and analyzing all direct and indirect costs of each procedure, according all its activities. Traditional costing methods, like those for estimating incomes and expenses per procedure or fixed and variable costs per procedure, which are widely used in break-even point analysis and the method of ratio-of-costs-to-charges per procedure may be easily performed in nuclear medicine departments, to evaluate the variability and differences between costs and reimbursement - charges.

  12. Agglomeration of SRC residues. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Theodore, F.W.; Wasson, G.E.

    1982-01-01

    EPRI contracted with CCDC to agglomerate Kerr-McGee ash concentrate and determine whether the agglomerates could be used as a fixed-bed gasifier feed. Briquettes were produced from Kerr-McGee ash concentrate which met CCDC's strength criteria for handling as feed to a fixed-bed gasifier. In addition, when shock heated under conditions simulating gasifier conditions, strong coke was produced demonstrating that the briquettes will not disintegrate during the initial temperature shock when charged to the gasifier. The conclusion of this study is that briquettes produced from the Kerr-McGee ash concentrate studied could be considered as feed for a fixed-bed gasifier. The CO/sub 2/-carbonmore » reactivity of the briquettes had values between a typical eastern and western coal. In the case of a dry bottom gasifier where the reactivity is important, it is not clear-cut whether the ash concentrate briquettes would be an economical feed. A closer inspection by a gasifier manufacturer is needed to resolve this issue. Since higher gasification temperatures are used in a slagging gasifier, the reactivity question is eliminated and the briquettes should be considered as a feed. This study does not deal with the exact design of a gasifier since this is a function of the type used. The gasifier manufacturer should be considered in future work for their input on critical design considerations i.e. stirrer design, etc.« less

  13. Finding fixed satellite service orbital allotments with a k-permutation algorithm

    NASA Technical Reports Server (NTRS)

    Reilly, Charles H.; Mount-Campbell, Clark A.; Gonsalvez, David J. A.

    1990-01-01

    A satellite system synthesis problem, the satellite location problem (SLP), is addressed. In SLP, orbital locations (longitudes) are allotted to geostationary satellites in the fixed satellite service. A linear mixed-integer programming model is presented that views SLP as a combination of two problems: the problem of ordering the satellites and the problem of locating the satellites given some ordering. A special-purpose heuristic procedure, a k-permutation algorithm, has been developed to find solutions to SLPs. Solutions to small sample problems are presented and analyzed on the basis of calculated interferences.

  14. Final Report on the Audit of Subcontract Prices on Firm-Fixed-Price Contracts Awarded to McDonnell Aircraft Company

    DTIC Science & Technology

    1990-12-03

    This is our final report on the audit of Subcontract Prices on Firm-Fixed-Price Contracts Awarded to McDonnell Aircraft Company (MCAIR). The Contract Management Directorate made the audit from October 1989 through June 1990. The objective of the audit was to compare proposed and negotiated subcontract prices and determine reasons for significant variances. We also evaluated applicable internal control procedures. For a 6-month period ending December 1989, MCAIR issued 517 subcontracts valued at $679 million.

  15. Repair of bis-acryl provisional restorations using flowable composite resin.

    PubMed

    Bohnenkamp, David M; Garcia, Lily T

    2004-11-01

    Provisional restorations provide interim coverage for prepared teeth while fixed definitive restorations are fabricated. Several types of autopolymerizing acrylic resins have been used for many years to fabricate provisional restorations. In recent years, bis-acryl resin composite material has gained popularity among clinicians for the direct fabrication of provisional fixed restorations. Occasionally, deficiencies may occur while fabricating a direct provisional restoration and require chairside repair. This article describes an effective procedure for the use of light-polymerized flowable composite resin for the intraoral repair of bis-acryl provisional restorations.

  16. [Demonstration plan used in the study of human reproduction in the district of Sao Paulo. 1967].

    PubMed

    Silva, Eunice Pinho de Castro

    2006-10-01

    This work presents the sampling procedure used to select the sample got for a "Human Reproduction Study in the District of São Paulo" (Brazil), done by the Department of Applied Statistics of "Faculdade de Higiene e Saúde Pública da Universidade de São Paulo". The procedure tried to solve the situation which resulted from the limitation in cost, time and lack of a frame that could be used in order to get a probability sample in the fixed term of time and with the fixed cost. It consisted in a two stage sampling with dwelling-units as primary units and women as secondary units. At the first stage, it was used stratified sampling in which sub-districts were taken as strata. In order to select primary units, there was a selection of points ("starting points") on the maps of subdistricts by a procedure that was similar to that one called "square grid" but differed from this in several aspects. There were fixed rules to establish a correspondence between each selected "starting point" and a set of three dwelling units where at least one woman of the target population lived. In the selected dwelling units where more than one woman of target population lived, there was a sub-sampling in order to select one of them. In this selection each woman living in the dwelling unit had equal probability of selection. Several "no-answer" cases and correspondent instructions to be followed by the interviewers are presented too.

  17. Transformation between surface spherical harmonic expansion of arbitrary high degree and order and double Fourier series on sphere

    NASA Astrophysics Data System (ADS)

    Fukushima, Toshio

    2018-02-01

    In order to accelerate the spherical harmonic synthesis and/or analysis of arbitrary function on the unit sphere, we developed a pair of procedures to transform between a truncated spherical harmonic expansion and the corresponding two-dimensional Fourier series. First, we obtained an analytic expression of the sine/cosine series coefficient of the 4 π fully normalized associated Legendre function in terms of the rectangle values of the Wigner d function. Then, we elaborated the existing method to transform the coefficients of the surface spherical harmonic expansion to those of the double Fourier series so as to be capable with arbitrary high degree and order. Next, we created a new method to transform inversely a given double Fourier series to the corresponding surface spherical harmonic expansion. The key of the new method is a couple of new recurrence formulas to compute the inverse transformation coefficients: a decreasing-order, fixed-degree, and fixed-wavenumber three-term formula for general terms, and an increasing-degree-and-order and fixed-wavenumber two-term formula for diagonal terms. Meanwhile, the two seed values are analytically prepared. Both of the forward and inverse transformation procedures are confirmed to be sufficiently accurate and applicable to an extremely high degree/order/wavenumber as 2^{30} {≈ } 10^9. The developed procedures will be useful not only in the synthesis and analysis of the spherical harmonic expansion of arbitrary high degree and order, but also in the evaluation of the derivatives and integrals of the spherical harmonic expansion.

  18. 'Real-world' compensatory behaviour with low nicotine concentration e-liquid: subjective effects and nicotine, acrolein and formaldehyde exposure.

    PubMed

    Dawkins, Lynne; Cox, Sharon; Goniewicz, Maciej; McRobbie, Hayden; Kimber, Catherine; Doig, Mira; Kośmider, Leon

    2018-06-07

    To compare the effects of i) high versus low nicotine concentration e-liquid, ii) fixed versus adjustable power and iii) the interaction between the two on: a) vaping behaviour, b) subjective effects, c) nicotine intake, and d) exposure to acrolein and formaldehyde in e-cigarette users vaping in their everyday setting. Counterbalanced, repeated measures with four conditions: i) low nicotine (6 mg/mL)/fixed power; ii) low nicotine/adjustable power; iii) high nicotine (18 mg/mL)/fixed power; iv) high nicotine/adjustable power. London and the South East, England. Twenty experienced e-cigarette users (recruited between September 2016 and February 2017) vaped ad libitum using an eVic Supreme™ with a 'Nautilus Aspire' tank over four weeks (one week per condition). Puffing patterns (daily puff number [PN], puff duration [PD], inter-puff interval [IPI]), mL of e-liquid consumed, changes to power (where permitted), and subjective effects (urge to vape, nicotine withdrawal symptoms) were measured in each condition. Nicotine intake was measured via salivary cotinine. 3-hydroxypropylmercapturic acid (3-HPMA), a metabolite of the toxicant acrolein, and formate, a metabolite of the carcinogen formaldehyde, were measured in urine. There was a significant nicotine concentration x power interaction for PD (p<0.01). PD was longer with low nicotine/fixed power compared with i) high nicotine/fixed power (p< 0.001 and ii) low nicotine/adjustable power (p< 0.01). PN and liquid consumed were higher in the low versus high nicotine condition (main effect of nicotine, p<0.05). Urge to vape and withdrawal symptoms were lower, and nicotine intake was higher, in the high nicotine condition (main effects of nicotine: p<0.01). Whilst acrolein levels did not differ, there was a significant nicotine x power interaction for formaldehyde (p<0.05). Use of a lower nicotine concentration e-liquid may be associated with compensatory behaviour (e.g., higher number and duration of puffs) and increases in negative affect, urge to vape, and formaldehyde exposure. This article is protected by copyright. All rights reserved.

  19. Specialty service contracting.

    PubMed

    Malcolm, C L; Fukui, M

    1993-01-01

    Package pricing of specific services and procedures can be an effective cost-containment and marketing tool for payers and providers. Payers can secure fixed prices at discounted rates, and hospitals and physicians can retain and gain market share in an increasingly competitive health care market. Successful implementation of a package pricing strategy, however, requires a careful assessment of both market and operational factors. This chapter outlines how to identify opportunities for package pricing and how to establish rates and procedures.

  20. An Introduction to Photomicrography.

    ERIC Educational Resources Information Center

    Judson, Peter

    1979-01-01

    Described are various methods for producing black and white photographs of microscope slides using single lens reflex, fixed lens, and plate cameras. Procedures for illumination, film processing, mounting, and projection are also discussed. A table of comparative film speeds is included. (CS)

  1. GASB 8 Compliance; Guidelines to Ease the Pain.

    ERIC Educational Resources Information Center

    McDougall, Donald B.

    1991-01-01

    Offers advice to schools and colleges attempting to bring their existing accounting procedures into conformity with "generally accepted accounting principles." Provides data categories for school asset lists and definitions of "cost" most frequently used in fixed asset management. (MLF)

  2. 75 FR 19401 - Petition for Reconsideration of Action in Rulemaking Proceeding

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-14

    ... Procedures to Govern the Use of Satellite Earth Stations on Board Vessels in the 5925-6425 MHz/3700-4200 MHz...-Mounted Earth Stations in Certain Frequency Bands Allocated to the Fixed-Satellite Service (IB Docket No...

  3. Emerging drugs for hemophilia B.

    PubMed

    Mannucci, Pier Mannuccio; Franchini, Massimo

    2014-09-01

    Hemophilia B is a rare congenital bleeding disorder characterized by a deficiency of coagulation factor IX (FIX). Hemophilia B patients experience mild-to-severe bleeding complications according to the degree of FIX defect. Prophylaxis, with regular infusion of FIX concentrates, is nowadays, the mainstay of hemophilia care. However, because the relatively short half-life of such products necessitates frequent infusions and thus makes patients' adherence difficult, a number of strategies have been implemented to improve the pharmacokinetics of FIX clotting factors. This review summarizes the main results of Phase I/II and III studies on new FIX molecules engineered to have a longer half-life. Several technologies are being applied to extend FIX half-life, including Fc fusion, recombinant (r) albumin fusion and the addition of PEG polymers. By prolonging the FIX half-life up to 5 times, long-acting FIX products are expected to substantially improve the management of hemophilia B patients, allowing less frequent infusions and improving patients' adherence to prophylactic regimens and individualized treatments. Some of them are at an advanced stage of development, such as the rFIX-Fc which has been launched in March 2014. Along with the ongoing Phase III trials, long-term post-marketing surveillance studies are needed to assess their safety and effectiveness and their impact on patients' quality of life.

  4. Parabolic Dish Concentrator (PDC-1)

    NASA Technical Reports Server (NTRS)

    Dennison, E. W.; Argoud, M. J.

    1984-01-01

    The design, construction, and installation of the Parabolic Dish Concentrator, Type 1 (PDC-1) has been one of the most significant JPL concentrator projects because of the knowledge gained about this type of concentrator and the development of design, testing, and analysis procedures which are applicable to all solar concentrator projects. The need for these procedures was more clearly understood during the testing period which started with the prototype panel evaluation and ended with the performance characterization of the completed concentrator. For each phase of the test program, practical test procedures were required and these procedures defined the mathematical analysis which was essential for successful concentrator development. The concentrator performance appears to be limited only by the distortions resulting from thermal gradients through the reflecting panels. Simple optical testing can be extremely effective, but comprehensive mechanical and optical analysis is essential for cost effective solar concentrator development.

  5. Histological Assessment of PAXgene Tissue Fixation and Stabilization Reagents

    PubMed Central

    Kap, Marcel; Smedts, Frank; Oosterhuis, Wolter; Winther, Rosa; Christensen, Nanna; Reischauer, Bilge; Viertler, Christian; Groelz, Daniel; Becker, Karl-Friedrich; Zatloukal, Kurt; Langer, Rupert; Slotta-Huspenina, Julia; Bodo, Koppany; de Jong, Bas; Oelmuller, Uwe; Riegman, Peter

    2011-01-01

    Within SPIDIA, an EC FP7 project aimed to improve pre analytic procedures, the PAXgene Tissue System (PAXgene), was designed to improve tissue quality for parallel molecular and morphological analysis. Within the SPIDIA project promising results were found in both genomic and proteomic experiments with PAXgene-fixed and paraffin embedded tissue derived biomolecules. But, for this technology to be accepted for use in both clinical and basic research, it is essential that its adequacy for preserving morphology and antigenicity is validated relative to formalin fixation. It is our aim to assess the suitability of PAXgene tissue fixation for (immuno)histological methods. Normal human tissue specimens (n = 70) were collected and divided into equal parts for fixation either with formalin or PAXgene. Sections of the obtained paraffin-embedded tissue were cut and stained. Morphological aspects of PAXgene-fixed tissue were described and also scored relative to formalin-fixed tissue. Performance of PAXgene-fixed tissue in immunohistochemical and in situ hybridization assays was also assessed relative to the corresponding formalin-fixed tissues. Morphology of PAXgene-fixed paraffin embedded tissue was well preserved and deemed adequate for diagnostics in most cases. Some antigens in PAXgene-fixed and paraffin embedded sections were detectable without the need for antigen retrieval, while others were detected using standard, formalin fixation based, immunohistochemistry protocols. Comparable results were obtained with in situ hybridization and histochemical stains. Basically all assessed histological techniques were found to be applicable to PAXgene-fixed and paraffin embedded tissue. In general results obtained with PAXgene-fixed tissue are comparable to those of formalin-fixed tissue. Compromises made in morphology can be called minor compared to the advantages in the molecular pathology possibilities. PMID:22110732

  6. Evidence-Based Design of Fixed-Dose Combinations: Principles and Application to Pediatric Anti-Tuberculosis Therapy.

    PubMed

    Svensson, Elin M; Yngman, Gunnar; Denti, Paolo; McIlleron, Helen; Kjellsson, Maria C; Karlsson, Mats O

    2018-05-01

    Fixed-dose combination formulations where several drugs are included in one tablet are important for the implementation of many long-term multidrug therapies. The selection of optimal dose ratios and tablet content of a fixed-dose combination and the design of individualized dosing regimens is a complex task, requiring multiple simultaneous considerations. In this work, a methodology for the rational design of a fixed-dose combination was developed and applied to the case of a three-drug pediatric anti-tuberculosis formulation individualized on body weight. The optimization methodology synthesizes information about the intended use population, the pharmacokinetic properties of the drugs, therapeutic targets, and practical constraints. A utility function is included to penalize deviations from the targets; a sequential estimation procedure was developed for stable estimation of break-points for individualized dosing. The suggested optimized pediatric anti-tuberculosis fixed-dose combination was compared with the recently launched World Health Organization-endorsed formulation. The optimized fixed-dose combination included 15, 36, and 16% higher amounts of rifampicin, isoniazid, and pyrazinamide, respectively. The optimized fixed-dose combination is expected to result in overall less deviation from the therapeutic targets based on adult exposure and substantially fewer children with underexposure (below half the target). The development of this design tool can aid the implementation of evidence-based formulations, integrating available knowledge and practical considerations, to optimize drug exposures and thereby treatment outcomes.

  7. Vibrational and rotational transitions in low-energy electron-diatomic-molecule collisions. I - Close-coupling theory in the moving body-fixed frame. II - Hybrid theory and close-coupling theory: An /l subscript z-prime/-conserving close-coupling approximation

    NASA Technical Reports Server (NTRS)

    Choi, B. H.; Poe, R. T.

    1977-01-01

    A detailed vibrational-rotational (V-R) close-coupling formulation of electron-diatomic-molecule scattering is developed in which the target molecular axis is chosen to be the z-axis and the resulting coupled differential equation is solved in the moving body-fixed frame throughout the entire interaction region. The coupled differential equation and asymptotic boundary conditions in the body-fixed frame are given for each parity, and procedures are outlined for evaluating V-R transition cross sections on the basis of the body-fixed transition and reactance matrix elements. Conditions are discussed for obtaining identical results from the space-fixed and body-fixed formulations in the case where a finite truncated basis set is used. The hybrid theory of Chandra and Temkin (1976) is then reformulated, relevant expressions and formulas for the simultaneous V-R transitions of the hybrid theory are obtained in the same forms as those of the V-R close-coupling theory, and distorted-wave Born-approximation expressions for the cross sections of the hybrid theory are presented. A close-coupling approximation that conserves the internuclear axis component of the incident electronic angular momentum (l subscript z-prime) is derived from the V-R close-coupling formulation in the moving body-fixed frame.

  8. The pharmacokinetics of enteral antituberculosis drugs in patients requiring intensive care.

    PubMed

    Koegelenberg, C F N; Nortje, A; Lalla, U; Enslin, A; Irusen, E M; Rosenkranz, B; Seifart, H I; Bolliger, C T

    2013-04-05

    There is a paucity of data on the pharmacokinetics of fixed-dose combination enteral antituberculosis treatment in critically ill patients. To establish the pharmacokinetic profile of a fixed-dose combination of rifampicin, isoniazid, pyrazinamide and ethambutol given according to weight via a nasogastric tube to patients admitted to an intensive care unit (ICU). We conducted a prospective, observational study on 10 patients (mean age 32 years, 6 male) admitted to an ICU and treated for tuberculosis (TB). Serum concentrations of the drugs were determined at eight predetermined intervals over 24 hours by means of high-performance liquid chromatography. The therapeutic maximum plasma concentration (Cmax) for rifampicin at time to peak concentration was achieved in only 4 patients, whereas 2 did not achieve therapeutic Cmax for isoniazid. No patient reached sub-therapeutic Cmax for pyrazinamide (6 were within and 4 above therapeutic range). Three patients reached sub-therapeutic Cmax for ethambutol, and 6 patients were within and 1 above the therapeutic range. Patients with a sub-therapeutic rifampicin level had a higher mean Acute Physiology and Chronic Health Evaluation II (APACHE II) score (p=0.03) and a lower estimated glomerular filtration rate (GFR) (p=0.03). A fixed-dose combination tablet, crushed and mixed with water, given according to weight via a nasogastric tube to patients with TB admitted to an ICU resulted in sub-therapeutic rifampicin plasma concentrations in the majority of patients, whereas the other drugs had a more favourable pharmacokinetic profile. Patients with a sub-therapeutic rifampicin concentration had a higher APACHE II score and a lower estimated GFR, which may contribute to suboptimal outcomes in critically ill patients. Studies in other settings have reported similar proportions of patients with 'sub-therapeutic' rifampicin concentrations.

  9. Survey mirrors and lenses and their required surface accuracy. Volume 2. Concentrator optical performance software (COPS) user's manual. Final report for September 15, 1978-December 1, 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1980-01-01

    The mathematical modeling of 11 different concentrating collectors is documented and instructions are given for use of the computer code. The 11 concentrators modeled are: faceted mirror concentration; fixed mirror, two-axis tracking receiver; parabolic trough collector; linear Fresnel; incremental reflector; inflated cylindrical concentrator; CPC-involute reflector with evacuated receiver; CPC-parabolic/involute reflector; V trough collectors, imaging collapsing concentrator; and parabolic dish collector. (MHR)

  10. Tailoring treatment of haemophilia B: accounting for the distribution and clearance of standard and extended half-life FIX concentrates.

    PubMed

    Iorio, Alfonso; Fischer, Kathelijn; Blanchette, Victor; Rangarajan, Savita; Young, Guy; Morfini, Massimo

    2017-06-02

    The prophylactic administration of factor IX (FIX) is considered the most effective treatment for haemophilia B. The inter-individual variability and complexity of the pharmacokinetics (PK) of FIX, and the rarity of the disease have hampered identification of an optimal treatment regimens. The recent introduction of extended half-life recombinant FIX molecules (EHL-rFIX), has prompted a thorough reassessment of the clinical efficacy, PK and pharmacodynamics of plasma-derived and recombinant FIX. First, using longer sampling times and multi-compartmental PK models has led to more precise (and favourable) PK for FIX than was appreciated in the past. Second, investigating the distribution of FIX in the body beyond the vascular space (which is implied by its complex kinetics) has opened a new research field on the role for extravascular FIX. Third, measuring plasma levels of EHL-rFIX has shown that different aPTT reagents have different accuracy in measuring different FIX molecules. How will this new knowledge reflect on clinical practice? Clinical decision making in haemophilia B requires some caution and expertise. First, comparisons between different FIX molecules must be assessed taking into consideration the comparability of the populations studied and the PK models used. Second, individual PK estimates must rely on multi-compartmental models, and would benefit from adopting a population PK approach. Optimal sampling times need to be adapted to the prolonged half-life of the new EHL FIX products. Finally, costs considerations may apply, which is beyond the scope of this manuscript but might be deeply connected with the PK considerations discussed in this communication.

  11. Fixed-Cell Imaging of Schizosaccharomyces pombe.

    PubMed

    Hagan, Iain M; Bagley, Steven

    2016-07-01

    The acknowledged genetic malleability of fission yeast has been matched by impressive cytology to drive major advances in our understanding of basic molecular cell biological processes. In many of the more recent studies, traditional approaches of fixation followed by processing to accommodate classical staining procedures have been superseded by live-cell imaging approaches that monitor the distribution of fusion proteins between a molecule of interest and a fluorescent protein. Although such live-cell imaging is uniquely informative for many questions, fixed-cell imaging remains the better option for others and is an important-sometimes critical-complement to the analysis of fluorescent fusion proteins by live-cell imaging. Here, we discuss the merits of fixed- and live-cell imaging as well as specific issues for fluorescence microscopy imaging of fission yeast. © 2016 Cold Spring Harbor Laboratory Press.

  12. Rapid demonstration of Legionella pneumophila in unembedded tissue. An adaptation of the Giménez stain.

    PubMed

    Greer, P W; Chandler, F W; Hicklin, M D

    1980-06-01

    The Giménez stain, originally developed for demonstrating rickettsiae, readily stained the Legionnaires' disease bacterium (Legionella pneumophila) in frozen tissue sections and smears of fresh or formalin-fixed lung tissue from patients who had confirmed Legionnaires' disease. With the Giménez procedure, the bacterium stained bright red against a blue-green background. The tissue Gram procedures also stained L. pneumophila in frozen sections and smears, but the staining reaction was weak, and these stains were neither as sensitive nor a consistent as the Giménez procedure.

  13. Relative toxicity of the pyrolysis products from some thermoplastic and thermoset polymers

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Gilwee, W. J., Jr.; Hilado, C. J.

    1978-01-01

    Relative toxicity data on the pyrolysis products of a variety of thermoplastic and thermoset polymers are presented. The data are presented in terms of time to incapacitation and time to death with a fixed sample weight of 1.0 g, and in terms of the apparent lethal concentration required to produce 50 percent mortality within a fixed exposure period of 30 min.

  14. Indirect vs direct bonding of mandibular fixed retainers in orthodontic patients: a single-center randomized controlled trial comparing placement time and failure over a 6-month period.

    PubMed

    Bovali, Efstathia; Kiliaridis, Stavros; Cornelis, Marie A

    2014-12-01

    The objective of this 2-arm parallel single-center trial was to compare placement time and numbers of failures of mandibular lingual retainers bonded with an indirect procedure vs a direct bonding procedure. Sixty-four consecutive patients at the postgraduate orthodontic clinic of the University of Geneva in Switzerland scheduled for debonding and mandibular fixed retainer placement were randomly allocated to either an indirect bonding procedure or a traditional direct bonding procedure. Eligibility criteria were the presence of the 4 mandibular incisors and the 2 mandibular canines, and no active caries, restorations, fractures, or periodontal disease of these teeth. The patients were randomized in blocks of 4; the randomization sequence was generated using an online randomization service (www.randomization.com). Allocation concealment was secured by contacting the sequence generator for treatment assignment; blinding was possible for outcome assessment only. Bonding time was measured for each procedure. Unpaired t tests were used to assess differences in time. Patients were recalled at 1, 2, 4, and 6 months after bonding. Mandibular fixed retainers having at least 1 composite pad debonded were considered as failures. The log-rank test was used to compare the Kaplan-Meier survival curves of both procedures. A test of proportion was applied to compare the failures at 6 months between the treatment groups. Sixty-four patients were randomized in a 1:1 ratio. One patient dropped out at baseline after the bonding procedure, and 3 patients did not attend the recalls at 4 and 6 months. Bonding time was significantly shorter for the indirect procedure (321 ± 31 seconds, mean ± SD) than for the direct procedure (401 ± 40 seconds) (per protocol analysis of 63 patients: mean difference = 80 seconds; 95% CI = 62.4-98.1; P <0.001). The 6-month numbers of failures were 10 of 31 (32%) with the indirect technique and 7 of 29 (24%) with the direct technique (log rank: P = 0.35; test of proportions: risk difference = 0.08; 95% CI = -0.15 to 0.31; P = 0.49). No serious harm was observed except for plaque accumulation. Indirect bonding was statistically significantly faster than direct bonding, with both techniques showing similar risks of failure. This trial was not registered. The protocol was not published before trial commencement. No funding or conflict of interest to be declared. Copyright © 2014 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  15. Free Gingival Graft to Increase Keratinized Mucosa after Placing of Mandibular Fixed Implant-Supported Prosthesis

    PubMed Central

    Marcantonio, Elcio

    2017-01-01

    Insufficiently keratinized tissue can be increased surgically by free gingival grafting. The presence or reconstruction of keratinized mucosa around the implant can facilitate restorative procedure and allow the maintenance of an oral hygiene routine without irritation or discomfort to the patient. The aim of this clinical case report is to describe an oral rehabilitation procedure of an edentulous patient with absence of keratinized mucosa in the interforaminal area, using a free gingival graft associated with a mandibular fixed implant-supported prosthesis. The treatment included the manufacturing of a maxillary complete denture and a mandibular fixed implant-supported prosthesis followed by a free gingival graft to increase the width of the mandibular keratinized mucosa. Free gingival graft was obtained from the palate and grafted on the buccal side of interforaminal area. The follow-up of 02 and 12 months after mucogingival surgery showed that the free gingival graft promoted peri-implant health, hygiene, and patient comfort. Clinical Significance. The free gingival graft is an effective treatment in increasing the width of mandibular keratinized mucosa on the buccal side of the interforaminal area and provided an improvement in maintaining the health of peri-implant tissues which allows for better oral hygiene. PMID:28293441

  16. FixO3 project results, legacy and module migration to EMSO

    NASA Astrophysics Data System (ADS)

    Lampitt, Richard

    2017-04-01

    The fixed point open ocean observatory network (FixO3) project is an international project aimed at integrating in a single network all fixed point open ocean observatories operated by European organisations and to harmonise and coordinate technological, procedural and data management across the stations. The project is running for four years since September 2013 with 29 partners across Europe and a budget of 7M Euros and is now coming to its final phase. In contrast to several past programmes, the opportunity has arisen to ensure that many of the project achievements can migrate into the newly formed European Multidisciplinary Seafloor and water column Observatory (EMSO) research infrastructure. The final phase of the project will focus on developing a strategy to transfer the results in an efficient way to maintain their relevance and maximise their use. In this presentation, we will highlight the significant achievements of FixO3 over the past three years focussing on the modules which will be transferred to EMSO in the coming 9 months. These include: 1. Handbook of best practices for operating fixed point observatories 2. Metadata catalogue 3. Earth Virtual Observatory (EarthVO) for data visualisation and comparison 4. Open Ocean Observatory Yellow Pages (O3YP) 5. Training material for hardware, data and data products used

  17. Biodegradation of Methylene Blue Dye by Sequential Treatment Using Anaerobic Hybrid Reactor and Submerged Aerobic Fixed Film Bioreactor

    NASA Astrophysics Data System (ADS)

    Farooqi, Izharul H.; Basheer, Farrukh; Tiwari, Pradeepika

    2017-12-01

    Laboratory scale experiments were carried out to access the feasibility of sequential anaerobic/aerobic biological treatment for the biodegradation of Methylene Blue (MB) dye. Anaerobic studies were performed using anaerobic hybrid reactor (consisting of UASB and Anaerobic filter) whereas submerged aerobic fixed film reactor was used as aerobic reactor. Degradation of MB dye was attempted using neutralized acetic acid (1000 mg/L) as co-substrate. MB dye concentration was stepwise increased from 10 to 70 mg/L after reaching steady state in each dye concentration. Such a gradual increase in the dye concentration helps in the proper acclimatization of the sludge to dyes thereby avoiding the possible inhibitory effects to biological activities at high dye concentrations. The overall treatment efficiency of MB through sequential anaerobic-aerobic reactor operation was 90% at maximum attempted dye concentration of 70 mg/L. The effluent from anaerobic reactor was analysed for intermediate biodegradation products through HPLC. It was observed that catechol, quinone, amino pyrine, 1,4 diamino benzene were present. However they were absent in final effluent.

  18. Synergistic Interaction of Retigabine with Levetiracetam in the Mouse Maximal Electroshock-Induced Seizure Model: A Type II Isobolographic Analysis.

    PubMed

    Luszczki, Jarogniew J; Zagaja, Mirosław; Miziak, Barbara; Florek-Luszczki, Magdalena; Czuczwar, Stanislaw J

    2015-01-01

    To assess interactions between retigabine and levetiracetam in suppressing maximal electroshock-induced tonic seizures in Albino Swiss mice, type II isobolographic analysis was used. Total brain antiepileptic drug concentrations were measured with high pressure liquid chromatography. The combinations of retigabine with levetiracetam at the fixed-ratios of 1:5 and 1:10 were supra-additive (synergistic; p < 0.05) in terms of seizure suppression, while the combinations at the fixed-ratios of 1:1 and 1:2 were additive. No pharmacokinetic changes in total brain concentrations of levetiracetam and retigabine were documented, indicating the pharmacodynamic nature of interaction between these antiepileptic drugs in the mouse maximal electroshock-induced tonic seizure model. The combination of retigabine with levetiracetam at the fixed-ratios of 1:5 and 1:10 appears to be particularly beneficial combination exerting supra-additive interaction in suppressing maximal electroshock-induced tonic seizures. © 2015 S. Karger AG, Basel.

  19. Profile of clindamycin phosphate 1.2%/benzoyl peroxide 3.75% aqueous gel for the treatment of acne vulgaris

    PubMed Central

    Nguyen, Tuyet A; Eichenfield, Lawrence F

    2015-01-01

    Acne vulgaris is a common and chronic skin disease, and is a frequent source of morbidity for affected patients. Treatment of acne vulgaris is often difficult due to the multifactorial nature of this disease. Combination therapy, such as that containing clindamycin and benzoyl peroxide, has become the standard of care. Several fixed formulations of clindamycin 1% and benzoyl peroxide of varying concentrations are available and have been used with considerable success. The major limitation is irritation and dryness from higher concentrations of benzoyl peroxide, and a combination providing optimal efficacy and tolerability has yet to be determined. Recently, a clindamycin and benzoyl peroxide 3.75% fixed combination formulation was developed. Studies have suggested that this formulation may be a safe and effective treatment regimen for patients with acne vulgaris. Here, we provide a brief review of acne pathogenesis, benzoyl peroxide and clindamycin, and profile a new Clindamycin-BP 3.75% fixed combination gel for the treatment of moderate-to-severe acne vulgaris. PMID:26604811

  20. The Superstatistical Nature and Interoccurrence Time of Atmospheric Mercury Concentration Fluctuations

    EPA Science Inventory

    The probability density function (PDF) of the time intervals between subsequent extreme events in atmospheric Hg0 concentration data series from different latitudes has been investigated. The Hg0 dynamic possesses a long-term memory autocorrelation function. Above a fixed thresh...

  1. Development of a depth-integrated sample arm (DISA) to reduce solids stratification bias in stormwater sampling

    USGS Publications Warehouse

    Selbig, William R.; ,; Roger T. Bannerman,

    2011-01-01

    A new depth-integrated sample arm (DISA) was developed to improve the representation of solids in stormwater, both organic and inorganic, by collecting a water quality sample from multiple points in the water column. Data from this study demonstrate the idea of vertical stratification of solids in storm sewer runoff. Concentrations of suspended sediment in runoff were statistically greater using a fixed rather than multipoint collection system. Median suspended sediment concentrations measured at the fixed location (near the pipe invert) were approximately double those collected using the DISA. In general, concentrations and size distributions of suspended sediment decreased with increasing vertical distance from the storm sewer invert. Coarser particles tended to dominate the distribution of solids near the storm sewer invert as discharge increased. In contrast to concentration and particle size, organic material, to some extent, was distributed homogenously throughout the water column, likely the result of its low specific density, which allows for thorough mixing in less turbulent water.

  2. Development of a depth-integrated sample arm to reduce solids stratification bias in stormwater sampling.

    PubMed

    Selbig, William R; Bannerman, Roger T

    2011-04-01

    A new depth-integrated sample arm (DISA) was developed to improve the representation of solids in stormwater, both organic and inorganic, by collecting a water quality sample from multiple points in the water column. Data from this study demonstrate the idea of vertical stratification of solids in storm sewer runoff. Concentrations of suspended sediment in runoff were statistically greater using a fixed rather than multipoint collection system. Median suspended sediment concentrations measured at the fixed location (near the pipe invert) were approximately double those collected using the DISA. In general, concentrations and size distributions of suspended sediment decreased with increasing vertical distance from the storm sewer invert. Coarser particles tended to dominate the distribution of solids near the storm sewer invert as discharge increased. In contrast to concentration and particle size, organic material, to some extent, was distributed homogenously throughout the water column, likely the result of its low specific density, which allows for thorough mixing in less turbulent water.

  3. Development of a depth-integrated sample arm to reduce solids stratification bias in stormwater sampling

    USGS Publications Warehouse

    Selbig, W.R.; Bannerman, R.T.

    2011-01-01

    A new depth-integrated sample arm (DISA) was developed to improve the representation of solids in stormwater, both organic and inorganic, by collecting a water quality sample from multiple points in the water column. Data from this study demonstrate the idea of vertical stratification of solids in storm sewer runoff. Concentrations of suspended sediment in runoff were statistically greater using a fixed rather than multipoint collection system. Median suspended sediment concentrations measured at the fixed location (near the pipe invert) were approximately double those collected using the DISA. In general, concentrations and size distributions of suspended sediment decreased with increasing vertical distance from the storm sewer invert. Coarser particles tended to dominate the distribution of solids near the storm sewer invert as discharge increased. In contrast to concentration and particle size, organic material, to some extent, was distributed homogenously throughout the water column, likely the result of its low specific density, which allows for thorough mixing in less turbulent water. ?? 2010 Publishing Technology.

  4. Rapid Response Concentration-Controlled Desorption of Activated Carbon to Dampen Concentration Fluctuations

    DTIC Science & Technology

    2007-01-01

    Behavior of trickle - bed air biofilter for toluene removal: Effect of non-use periods. Environ. Prog. 2005, 24, 155-161. (3) Martin, F. J.; Loehr, R. C...dampen the fluctuation in acetone concentration at high concentrations. The effect of inlet concentration and empty bed contact time (EBCT) on dampening...oxidizer. The MSA-SST system is a fixed- bed system that rapidly controls the power that heats the adsorbent/adsorbate, resulting in controlled

  5. 47 CFR 101.1111 - Partitioning and disaggregation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS § 101.1111 Partitioning and disaggregation. (a) Definitions. Disaggregation. The assignment of discrete portions or “blocks” of spectrum licensed to a geographic licensee or qualifying entity. Partitioning. The assignment of geographic portions...

  6. 47 CFR 101.1112 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS § 101.1112 Definitions. (a) Scope. The definitions in this... small business. A very small business is an entity that, together with its affiliates and controlling...

  7. 47 CFR 101.1112 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS § 101.1112 Definitions. (a) Scope. The definitions in this... small business. A very small business is an entity that, together with its affiliates and controlling...

  8. 78 FR 26518 - Federal Acquisition Regulation; Government Property

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-07

    ... DEPARTMENT OF DEFENSE GENERAL SERVICES ADMINISTRATION NATIONAL AERONAUTICS AND SPACE ADMINISTRATION 48 CFR Part 52 Federal Acquisition Regulation; Government Property CFR Correction In Title 48 of... Termination for Convenience of the Government (Fixed-Price). * * * * * (i) The cost principles and procedures...

  9. 40 CFR 1065.940 - Emission calculations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... CONTROLS ENGINE-TESTING PROCEDURES Field Testing and Portable Emission Measurement Systems § 1065.940...-specific emissions for each test interval using any applicable information and instructions in the standard.... Determine this fixed value by engineering analysis. [75 FR 68467, Nov. 8, 2010] ...

  10. 47 CFR 101.1112 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Definitions. 101.1112 Section 101.1112 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS § 101.1112 Definitions. (a) Scope. The definitions in this...

  11. 47 CFR 101.1111 - Partitioning and disaggregation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Partitioning and disaggregation. 101.1111 Section 101.1111 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS § 101.1111 Partitioning and...

  12. 47 CFR 101.1109 - Records maintenance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Records maintenance. 101.1109 Section 101.1109 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS § 101.1109 Records maintenance. All winning bidders...

  13. 47 CFR 101.1111 - Partitioning and disaggregation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Partitioning and disaggregation. 101.1111 Section 101.1111 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS § 101.1111 Partitioning and...

  14. 47 CFR 101.1109 - Records maintenance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Records maintenance. 101.1109 Section 101.1109 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS § 101.1109 Records maintenance. All winning bidders...

  15. 47 CFR 101.1109 - Records maintenance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Records maintenance. 101.1109 Section 101.1109 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS § 101.1109 Records maintenance. All winning bidders...

  16. 47 CFR 101.1111 - Partitioning and disaggregation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Partitioning and disaggregation. 101.1111 Section 101.1111 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS § 101.1111 Partitioning and...

  17. 47 CFR 101.1112 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Definitions. 101.1112 Section 101.1112 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS § 101.1112 Definitions. (a) Scope. The definitions in this...

  18. 47 CFR 101.1109 - Records maintenance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Records maintenance. 101.1109 Section 101.1109 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS § 101.1109 Records maintenance. All winning bidders...

  19. 47 CFR 101.1111 - Partitioning and disaggregation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Partitioning and disaggregation. 101.1111 Section 101.1111 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS § 101.1111 Partitioning and...

  20. 47 CFR 101.1112 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Definitions. 101.1112 Section 101.1112 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS § 101.1112 Definitions. (a) Scope. The definitions in this...

  1. Optimized manual and automated recovery of amplifiable DNA from tissues preserved in buffered formalin and alcohol-based fixative.

    PubMed

    Duval, Kristin; Aubin, Rémy A; Elliott, James; Gorn-Hondermann, Ivan; Birnboim, H Chaim; Jonker, Derek; Fourney, Ron M; Frégeau, Chantal J

    2010-02-01

    Archival tissue preserved in fixative constitutes an invaluable resource for histological examination, molecular diagnostic procedures and for DNA typing analysis in forensic investigations. However, available material is often limited in size and quantity. Moreover, recovery of DNA is often severely compromised by the presence of covalent DNA-protein cross-links generated by formalin, the most prevalent fixative. We describe the evaluation of buffer formulations, sample lysis regimens and DNA recovery strategies and define optimized manual and automated procedures for the extraction of high quality DNA suitable for molecular diagnostics and genotyping. Using a 3-step enzymatic digestion protocol carried out in the absence of dithiothreitol, we demonstrate that DNA can be efficiently released from cells or tissues preserved in buffered formalin or the alcohol-based fixative GenoFix. This preparatory procedure can then be integrated to traditional phenol/chloroform extraction, a modified manual DNA IQ or automated DNA IQ/Te-Shake-based extraction in order to recover DNA for downstream applications. Quantitative recovery of high quality DNA was best achieved from specimens archived in GenoFix and extracted using magnetic bead capture.

  2. Thermodynamics Calculation and Experimental Study on Separation of Bismuth from a Bismuth Glance Concentrate Through a Low-Temperature Molten Salt Smelting Process

    NASA Astrophysics Data System (ADS)

    Yang, Jian-Guang; He, De-Wen; Tang, Chao-Bo; Chen, Yong-Ming; Sun, Ya-Hui; Tang, Mo-Tang

    2011-08-01

    The main purpose of this study is to characterize and separate bismuth from a bismuth glance concentrate through a low-temperature, sulfur-fixing smelting process. This article reports on a study conducted on the optimization of process parameters, such as Na2CO3 and zinc oxide wt pct in charging, smelting temperature, smelting duration on the bismuth yield, resultant crude bismuth grade, and sulfur-fixing rate. A maximum bismuth recovery of 97.31 pct, crude bismuth grade of 96.93 pct, and 98.23 pct sulfur-fixing rate are obtained when a charge (containing 63.50 wt pct of Na2CO3 and 22.50 wt pct of bismuth glance, as well as 5 pct in excess of the stoichiometric requirement of zinc oxide dosage) is smelted at 1000 K (727 °C) for 150 minutes. This smelting operation is free from atmospheric pollution because zinc oxide is used as the sulfur-fixing agent, which can capture sulfur from bismuth sulfide and form the more thermodynamic-stable compound, zinc sulfide. The solid residue is subjected to a mineral dressing operation to obtain suspension, which is filtered to produce a cake, representing the solid particles of zinc sulfide. Based on the results of the chemical content analysis of the as-resultant zinc sulfide, more than 93 pct zinc sulfide can be recovered, and the recovered zinc sulfide grade can reach 60.20 pct. This material can be sold as zinc sulfide concentrate or roasted to be regenerated as zinc oxide.

  3. Vanadium Requirements and Uptake Kinetics in the Dinitrogen-Fixing Bacterium Azotobacter vinelandii▿

    PubMed Central

    Bellenger, J. P.; Wichard, T.; Kraepiel, A. M. L.

    2008-01-01

    Vanadium is a cofactor in the alternative V-nitrogenase that is expressed by some N2-fixing bacteria when Mo is not available. We investigated the V requirements, the kinetics of V uptake, and the production of catechol compounds across a range of concentrations of vanadium in diazotrophic cultures of the soil bacterium Azotobacter vinelandii. In strain CA11.70, a mutant that expresses only the V-nitrogenase, V concentrations in the medium between 10−8 and 10−6 M sustain maximum growth rates; they are limiting below this range and toxic above. A. vinelandii excretes in its growth medium micromolar concentrations of the catechol siderophores azotochelin and protochelin, which bind the vanadate oxoanion. The production of catechols increases when V concentrations become toxic. Short-term uptake experiments with the radioactive isotope 49V show that bacteria take up the V-catechol complexes through a regulated transport system(s), which shuts down at high V concentrations. The modulation of the excretion of catechols and of the uptake of the V-catechol complexes allows A. vinelandii to precisely manage its V homeostasis over a range of V concentrations, from limiting to toxic. PMID:18192412

  4. Remarks on a New Possible Discretization Scheme for Gauge Theories

    NASA Astrophysics Data System (ADS)

    Magnot, Jean-Pierre

    2018-03-01

    We propose here a new discretization method for a class of continuum gauge theories which action functionals are polynomials of the curvature. Based on the notion of holonomy, this discretization procedure appears gauge-invariant for discretized analogs of Yang-Mills theories, and hence gauge-fixing is fully rigorous for these discretized action functionals. Heuristic parts are forwarded to the quantization procedure via Feynman integrals and the meaning of the heuristic infinite dimensional Lebesgue integral is questioned.

  5. Remarks on a New Possible Discretization Scheme for Gauge Theories

    NASA Astrophysics Data System (ADS)

    Magnot, Jean-Pierre

    2018-07-01

    We propose here a new discretization method for a class of continuum gauge theories which action functionals are polynomials of the curvature. Based on the notion of holonomy, this discretization procedure appears gauge-invariant for discretized analogs of Yang-Mills theories, and hence gauge-fixing is fully rigorous for these discretized action functionals. Heuristic parts are forwarded to the quantization procedure via Feynman integrals and the meaning of the heuristic infinite dimensional Lebesgue integral is questioned.

  6. Iron deficiency increases growth and nitrogen-fixation rates of phosphorus-deficient marine cyanobacteria.

    PubMed

    Garcia, Nathan S; Fu, Feixue; Sedwick, Peter N; Hutchins, David A

    2015-01-01

    Marine dinitrogen (N2)-fixing cyanobacteria have large impacts on global biogeochemistry as they fix carbon dioxide (CO2) and fertilize oligotrophic ocean waters with new nitrogen. Iron (Fe) and phosphorus (P) are the two most important limiting nutrients for marine biological N2 fixation, and their availabilities vary between major ocean basins and regions. A long-standing question concerns the ability of two globally dominant N2-fixing cyanobacteria, unicellular Crocosphaera and filamentous Trichodesmium, to maintain relatively high N2-fixation rates in these regimes where both Fe and P are typically scarce. We show that under P-deficient conditions, cultures of these two cyanobacteria are able to grow and fix N2 faster when Fe deficient than when Fe replete. In addition, growth affinities relative to P increase while minimum concentrations of P that support growth decrease at low Fe concentrations. In Crocosphaera, this effect is accompanied by a reduction in cell sizes and elemental quotas. Relatively high growth rates of these two biogeochemically critical cyanobacteria in low-P, low-Fe environments such as those that characterize much of the oligotrophic ocean challenge the common assumption that low Fe levels can have only negative effects on marine primary producers. The closely interdependent influence of Fe and P on N2-fixing cyanobacteria suggests that even subtle shifts in their supply ratio in the past, present and future oceans could have large consequences for global carbon and nitrogen cycles.

  7. Optimizing tuning masses for helicopter rotor blade vibration reduction including computed airloads and comparison with test data

    NASA Technical Reports Server (NTRS)

    Pritchard, Jocelyn I.; Adelman, Howard M.; Walsh, Joanne L.; Wilbur, Matthew L.

    1992-01-01

    The development and validation of an optimization procedure to systematically place tuning masses along a rotor blade span to minimize vibratory loads are described. The masses and their corresponding locations are the design variables that are manipulated to reduce the harmonics of hub shear for a four-bladed rotor system without adding a large mass penalty. The procedure incorporates a comprehensive helicopter analysis to calculate the airloads. Predicting changes in airloads due to changes in design variables is an important feature of this research. The procedure was applied to a one-sixth, Mach-scaled rotor blade model to place three masses and then again to place six masses. In both cases the added mass was able to achieve significant reductions in the hub shear. In addition, the procedure was applied to place a single mass of fixed value on a blade model to reduce the hub shear for three flight conditions. The analytical results were compared to experimental data from a wind tunnel test performed in the Langley Transonic Dynamics Tunnel. The correlation of the mass location was good and the trend of the mass location with respect to flight speed was predicted fairly well. However, it was noted that the analysis was not entirely successful at predicting the absolute magnitudes of the fixed system loads.

  8. Numerical evaluation of static-chamber measurements of soil-atmospheric gas exchange--Identification of physical processes

    USGS Publications Warehouse

    Healy, Richard W.; Striegl, Robert G.; Russell, Thomas F.; Hutchinson, Gordon L.; Livingston, Gerald P.

    1996-01-01

    The exchange of gases between soil and atmosphere is an important process that affects atmospheric chemistry and therefore climate. The static-chamber method is the most commonly used technique for estimating the rate of that exchange. We examined the method under hypothetical field conditions where diffusion was the only mechanism for gas transport and the atmosphere outside the chamber was maintained at a fixed concentration. Analytical and numerical solutions to the soil gas diffusion equation in one and three dimensions demonstrated that gas flux density to a static chamber deployed on the soil surface was less in magnitude than the ambient exchange rate in the absence of the chamber. This discrepancy, which increased with chamber deployment time and air-filled porosity of soil, is attributed to two physical factors: distortion of the soil gas concentration gradient (the magnitude was decreased in the vertical component and increased in the radial component) and the slow transport rate of diffusion relative to mixing within the chamber. Instantaneous flux density to a chamber decreased continuously with time; steepest decreases occurred so quickly following deployment and in response to such slight changes in mean chamber headspace concentration that they would likely go undetected by most field procedures. Adverse influences of these factors were reduced by mixing the chamber headspace, minimizing deployment time, maximizing the height and radius of the chamber, and pushing the rim of the chamber into the soil. Nonlinear models were superior to a linear regression model for estimating flux densities from mean headspace concentrations, suggesting that linearity of headspace concentration with time was not necessarily a good indicator of measurement accuracy.

  9. [Development of a portable mid-infrared rapid analyzer for oil concentration in water based on MEMS linear sensor array].

    PubMed

    Gao, Zhi-fan; Zeng, Li-bo; Shi, Lei; Li, Kai; Yang, Yuan-zhou; Wu, Qiong-shui

    2014-06-01

    Aiming at the existing problems such as weak environmental adaptability, low analytic efficiency and poor measuring repeatability in the traditional spectral oil analyzers, the present paper designed a portable mid-infrared rapid analyzer for oil concentration in water. To reduce the volume of the instrument, the non-symmetrical folding M-type Czerny-Turner optical structure was adopted in the core optical path. With a periodically rotating chopper, controlled by digital PID algorithm, applied for infrared light modulation, the modulating accuracy reached ±0.5%. Different from traditional grating-scanning spectrophotometers, this instrument used a fixed grating for light dispersion and avoided rotating error in the course of the measuring procedures. A new-type MEMS infrared linear sensor array was applied for modulated spectral signals detection, which improved the measuring efficiency remarkably. Optical simulation and experimental results indicate that the spectral range is 2 800 - 3 200 cm(-1), the spectral resolution is 6 cm(-1) (@3 130 cm(-1)), and the signal to noise ratio is up to 5 200 : 1. The acquisition time is 13 milliseconds per spectrogram, and the standard deviation of absorbance is less than 3 x 10(-3). These performances meet the standards of oil concentration measurements perfectly. Compared with traditional infrared spectral analyzers for oil concentration, the instrument demonstrated in this paper has many advantages such as smaller size, more efficiency, higher precision, and stronger vibration & moisture isolation. In addition, the proposed instrument is especially suitable for the environmental monitoring departments to implement real-time measurements in the field for oil concentration in water, hence it has broad prospects of application in the field of water quality monitoring.

  10. Optimization of extraction procedures for ecotoxicity analyses: Use of TNT contaminated soil as a model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sunahara, G.I.; Renoux, A.Y.; Dodard, S.

    1995-12-31

    The environmental impact of energetic substances (TNT, RDX, GAP, NC) in soil is being examined using ecotoxicity bioassays. An extraction method was characterized to optimize bioassay assessment of TNT toxicity in different soil types. Using the Microtox{trademark} (Photobacterium phosphoreum) assay and non-extracted samples, TNT was most acutely toxic (IC{sub 50} = 1--9 PPM) followed by RDX and GAP; NC did not show obvious toxicity (probably due to solubility limitations). TNT (in 0.25% DMSO) yielded an IC{sub 50} 0.98 + 0.10 (SD) ppm. The 96h-EC{sub 50} (Selenastrum capricornutum growth inhibition) of TNT (1. 1 ppm) was higher than GAP and RDX;more » NC was not apparently toxic (probably due to solubility limitations). Soil samples (sand or a silt-sand mix) were spiked with either 2,000 or 20,000 mg TNT/kg soil, and were adjusted to 20% moisture. Samples were later mixed with acetonitrile, sonicated, and then treated with CaCl{sub 2} before filtration, HPLC and ecotoxicity analyses. Results indicated that: the recovery of TNT from soil (97.51% {+-} 2.78) was independent of the type of soil or moisture content; CaCl{sub 2} interfered with TNT toxicity and acetonitrile extracts could not be used directly for algal testing. When TNT extracts were diluted to fixed concentrations, similar TNT-induced ecotoxicities were generally observed and suggested that, apart from the expected effects of TNT concentrations in the soil, the soil texture and the moisture effects were minimal. The extraction procedure permits HPLC analyses as well as ecotoxicity testing and minimizes secondary soil matrix effects. Studies will be conducted to study the toxic effects of other energetic substances present in soil using this approach.« less

  11. Perioperative supplemental oxygen therapy and surgical site infection: a meta-analysis of randomized controlled trials.

    PubMed

    Qadan, Motaz; Akça, Ozan; Mahid, Suhal S; Hornung, Carlton A; Polk, Hiram C

    2009-04-01

    To conduct a meta-analysis of randomized controlled trials in which high inspired oxygen concentrations were compared with standard concentrations to assess the effect on the development of surgical site infections (SSIs). A systematic literature search was conducted using the MEDLINE, EMBASE, and Cochrane databases and included a manual search of references of original articles, poster presentations, and abstracts from major meetings ("gray" literature). Twenty-one of 2167 articles met the inclusion criteria. Of these, 5 randomized controlled trials (3001 patients) assessed the effect of perioperative supplemental oxygen use on the SSI rate. Studies used a treatment-inspired oxygen concentration of 80%. Maximum follow-up was 30 days. Data were abstracted by 3 independent reviewers using a standardized data collection form. Relative risks were reported using a fixed-effects model. Results were subjected to publication bias testing and sensitivity analyses. Infection rates were 12.0% in the control group and 9.0% in the hyperoxic group, with relative risk reduction of 25.3% (95% confidence interval [CI], 8.1%-40.1%) and absolute risk reduction of 3.0% (1.1%-5.3%). The overall risk ratio was 0.742 (95% CI, 0.599-0.919; P = .006). The benefit from increasing oxygen concentration was greater in colorectal-specific procedures, with a risk ratio of 0.556 (95% CI, 0.383-0.808; P = .002). Perioperative supplemental oxygen therapy exerts a significant beneficial effect in the prevention of SSIs. We recommend its use along with maintenance of normothermia, meticulous glycemic control, and preservation of intravascular volume perioperatively in the prevention of SSIs.

  12. Size distribution and concentration of soot generated in oil and gas-fired residential boilers under different combustion conditions

    NASA Astrophysics Data System (ADS)

    Jiménez, Santiago; Barroso, Jorge; Pina, Antonio; Ballester, Javier

    2016-05-01

    In spite of the relevance of residential heating burners in the global emission of soot particles to the atmosphere, relatively little information on their properties (concentration, size distribution) is available in the literature, and even less regarding the dependence of those properties on the operating conditions. Instead, the usual procedure to characterize those emissions is to measure the smoke opacity by several methods, among which the blackening of a paper after filtering a fixed amount of gas (Bacharach test) is predominant. In this work, the size distributions of the particles generated in the combustion of a variety of gaseous and liquid fuels in a laboratory facility equipped with commercial burners have been measured with a size classifier coupled to a particle counter in a broad range of operating conditions (air excesses), with simultaneous determination of the Bacharach index. The shape and evolution of the distribution with progressively smaller oxygen concentrations depends essentially on the state of the fuel: whereas the combustion of the gases results in monomodal distributions that 'shift' towards larger diameters, in the case of the gas-oils an ultrafine mode is always observed, and a secondary mode of coarse particle grows in relevance. In both cases, there is a strong, exponential correlation between the total mass concentration and the Bacharach opacity index, quite similar for both groups of fuels. The empirical expressions proposed may allow other researchers to at least estimate the emissions of numerous combustion facilities routinely characterized by their smoke opacities.

  13. Comparison of VFA titration procedures used for monitoring the biogas process.

    PubMed

    Lützhøft, Hans-Christian Holten; Boe, Kanokwan; Fang, Cheng; Angelidaki, Irini

    2014-05-01

    Titrimetric determination of volatile fatty acids (VFAs) contents is a common way to monitor a biogas process. However, digested manure from co-digestion biogas plants has a complex matrix with high concentrations of interfering components, resulting in varying results when using different titration procedures. Currently, no standardized procedure is used and it is therefore difficult to compare the performance among plants. The aim of this study was to evaluate four titration procedures (for determination of VFA-levels of digested manure samples) and compare results with gas chromatographic (GC) analysis. Two of the procedures are commonly used in biogas plants and two are discussed in literature. The results showed that the optimal titration results were obtained when 40 mL of four times diluted digested manure was gently stirred (200 rpm). Results from samples with different VFA concentrations (1-11 g/L) showed linear correlation between titration results and GC measurements. However, determination of VFA by titration generally overestimated the VFA contents compared with GC measurements when samples had low VFA concentrations, i.e. around 1 g/L. The accuracy of titration increased when samples had high VFA concentrations, i.e. around 5 g/L. It was further found that the studied ionisable interfering components had lowest effect on titration when the sample had high VFA concentration. In contrast, bicarbonate, phosphate and lactate had significant effect on titration accuracy at low VFA concentration. An extended 5-point titration procedure with pH correction was best to handle interferences from bicarbonate, phosphate and lactate at low VFA concentrations. Contrary, the simplest titration procedure with only two pH end-points showed the highest accuracy among all titration procedures at high VFA concentrations. All in all, if the composition of the digested manure sample is not known, the procedure with only two pH end-points should be the procedure of choice, due to its simplicity and accuracy. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. CFD convective flow simulation of the varying properties of CO2-H2O mixtures in geothermal systems.

    PubMed

    Yousefi, S; Atrens, A D; Sauret, E; Dahari, M; Hooman, K

    2015-01-01

    Numerical simulation of a geothermal reservoir, modelled as a bottom-heated square box, filled with water-CO2 mixture is presented in this work. Furthermore, results for two limiting cases of a reservoir filled with either pure water or CO2 are presented. Effects of different parameters including CO2 concentration as well as reservoir pressure and temperature on the overall performance of the system are investigated. It has been noted that, with a fixed reservoir pressure and temperature, any increase in CO2 concentration leads to better performance, that is, stronger convection and higher heat transfer rates. With a fixed CO2 concentration, however, the reservoir pressure and temperature can significantly affect the overall heat transfer and flow rate from the reservoir. Details of such variations are documented and discussed in the present paper.

  15. CFD Convective Flow Simulation of the Varying Properties of CO2-H2O Mixtures in Geothermal Systems

    PubMed Central

    Yousefi, S.; Atrens, A. D.; Sauret, E.; Dahari, M.; Hooman, K.

    2015-01-01

    Numerical simulation of a geothermal reservoir, modelled as a bottom-heated square box, filled with water-CO2 mixture is presented in this work. Furthermore, results for two limiting cases of a reservoir filled with either pure water or CO2 are presented. Effects of different parameters including CO2 concentration as well as reservoir pressure and temperature on the overall performance of the system are investigated. It has been noted that, with a fixed reservoir pressure and temperature, any increase in CO2 concentration leads to better performance, that is, stronger convection and higher heat transfer rates. With a fixed CO2 concentration, however, the reservoir pressure and temperature can significantly affect the overall heat transfer and flow rate from the reservoir. Details of such variations are documented and discussed in the present paper. PMID:25879074

  16. Impurity Correction Techniques Applied to Existing Doping Measurements of Impurities in Zinc

    NASA Astrophysics Data System (ADS)

    Pearce, J. V.; Sun, J. P.; Zhang, J. T.; Deng, X. L.

    2017-01-01

    Impurities represent the most significant source of uncertainty in most metal fixed points used for the realization of the International Temperature Scale of 1990 (ITS-90). There are a number of different methods for quantifying the effect of impurities on the freezing temperature of ITS-90 fixed points, many of which rely on an accurate knowledge of the liquidus slope in the limit of low concentration. A key method of determining the liquidus slope is to measure the freezing temperature of a fixed-point material as it is progressively doped with a known amount of impurity. Recently, a series of measurements of the freezing and melting temperature of `slim' Zn fixed-point cells doped with Ag, Fe, Ni, and Pb were presented. Here, additional measurements of the Zn-X system are presented using Ga as a dopant, and the data (Zn-Ag, Zn-Fe, Zn-Ni, Zn-Pb, and Zn-Ga) have been re-analyzed to demonstrate the use of a fitting method based on Scheil solidification which is applied to both melting and freezing curves. In addition, the utility of the Sum of Individual Estimates method is explored with these systems in the context of a recently enhanced database of liquidus slopes of impurities in Zn in the limit of low concentration.

  17. 21 CFR 1303.23 - Procedure for fixing individual manufacturing quotas.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... economic and physical availability of raw materials for use in manufacturing and for inventory purposes, yield and stability problems, potential disruptions to production (including possible labor strikes... current inventory position, the economic and physical availability of raw materials for use in...

  18. 47 CFR 1.903 - Authorization required.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL PRACTICE AND PROCEDURE Wireless Radio Services... the Wireless Radio Services must be used and operated only in accordance with the rules applicable to... operate mobile or fixed stations in the Wireless Radio Services, except for certain stations in the Rural...

  19. Study of the desorption of ethylene oxide fixed on various materials during sterilization by a new procedure

    NASA Technical Reports Server (NTRS)

    Lacomme, M.; Chaigneau, M.; Lemoan, G.

    1977-01-01

    A continuous sterilization process using ethylene oxide was studied in comparison with a classical method in order to evaluate gas retention as a function of time and temperature on polyethylene, PVC, and rubber materials.

  20. 49 CFR 1562.21 - Scope, general requirements, and definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... WASHINGTON, DC, METROPOLITAN AREA Ronald Reagan Washington National Airport: Enhanced Security Procedures for... to aircraft operations into or out of Ronald Reagan Washington National Airport (DCA), fixed base... not include an armed security officer. DCA means Ronald Reagan Washington National Airport. DASSP...

  1. 49 CFR 1562.21 - Scope, general requirements, and definitions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... WASHINGTON, DC, METROPOLITAN AREA Ronald Reagan Washington National Airport: Enhanced Security Procedures for... to aircraft operations into or out of Ronald Reagan Washington National Airport (DCA), fixed base... not include an armed security officer. DCA means Ronald Reagan Washington National Airport. DASSP...

  2. 47 CFR 101.1102-101.1105 - [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false [Reserved] 101.1102-101.1105 Section 101.1102-101.1105 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS § 101.1102-101.1105 [Reserved] ...

  3. 47 CFR 101.1102-101.1105 - [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false [Reserved] 101.1102-101.1105 Section 101.1102-101.1105 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS § 101.1102-101.1105 [Reserved] ...

  4. Management of Gustilo Anderson III B open tibial fractures by primary fascio-septo-cutaneous local flap and primary fixation: The 'fix and shift' technique.

    PubMed

    Ramasamy, P R

    2017-01-01

    Open fractures of tibia have posed great difficulty in managing both the soft tissue and the skeletal components of the injured limb. Gustilo Anderson III B open tibial fractures are more difficult to manage than I, II, and III A fractures. Stable skeletal fixation with immediate soft tissue cover has been the key to the successful outcome in treating open tibial fractures, in particular, Gustilo Anderson III B types. If the length of the open wound is larger and if the exposed surface of tibial fracture and tibial shaft is greater, then the management becomes still more difficult. Thirty six Gustilo Anderson III B open tibial fractures managed between June 2002 and December 2013 with "fix and shift" technique were retrospectively reviewed. All the 36 patients managed by this technique had open wounds measuring >5 cm (post debridement). Under fix and shift technique, stable fixation involved primary external fixator application or primary intramedullary nailing of the tibial fracture and immediate soft tissue cover involved septocutaneous shift, i.e., shifting of fasciocutaneous segments based on septocutaneous perforators. Primary fracture union rate was 50% and reoperation rate (bone stimulating procedures) was 50%. Overall fracture union rate was 100%. The rate of malunion was 14% and deep infection was 16%. Failure of septocutaneous shift was 2.7%. There was no incidence of amputation. Management of Gustilo Anderson III B open tibial fractures with "fix and shift" technique has resulted in better outcome in terms of skeletal factors (primary fracture union, overall union, and time for union and malunion) and soft tissue factors (wound healing, flap failure, access to secondary procedures, and esthetic appearance) when compared to standard methods adopted earlier. Hence, "fix and shift" could be recommended as one of the treatment modalities for open III B tibial fractures.

  5. The importance of fixed costs in animal health systems.

    PubMed

    Tisdell, C A; Adamson, D

    2017-04-01

    In this paper, the authors detail the structure and optimal management of health systems as influenced by the presence and level of fixed costs. Unlike variable costs, fixed costs cannot be altered, and are thus independent of the level of veterinary activity in the short run. Their importance is illustrated by using both single-period and multi-period models. It is shown that multi-stage veterinary decision-making can often be envisaged as a sequence of fixed-cost problems. In general, it becomes clear that, the higher the fixed costs, the greater the net benefit of veterinary activity must be, if such activity is to be economic. The authors also assess the extent to which it pays to reduce fixed costs and to try to compensate for this by increasing variable costs. Fixed costs have major implications for the industrial structure of the animal health products industry and for the structure of the private veterinary services industry. In the former, they favour market concentration and specialisation in the supply of products. In the latter, they foster increased specialisation. While cooperation by individual farmers may help to reduce their individual fixed costs, the organisational difficulties and costs involved in achieving this cooperation can be formidable. In such cases, the only solution is government provision of veterinary services. Moreover, international cooperation may be called for. Fixed costs also influence the nature of the provision of veterinary education.

  6. Human's choices in situations of time-based diminishing returns.

    PubMed Central

    Hackenberg, T D; Axtell, S A

    1993-01-01

    Three experiments examined adult humans' choices in situations with contrasting short-term and long-term consequences. Subjects were given repeated choices between two time-based schedules of points exchangeable for money: a fixed schedule and a progressive schedule that began at 0 s and increased by 5 s with each point delivered by that schedule. Under "reset" conditions, choosing the fixed schedule not only produced a point but it also reset the requirements of the progressive schedule to 0 s. In the first two experiments, reset conditions alternated with "no-reset" conditions, in which progressive-schedule requirements were independent of fixed-schedule choices. Experiment 1 entailed choices between a progressive-interval schedule and a fixed-interval schedule, the duration of which varied across conditions. Switching from the progressive- to the fixed-interval schedule was systematically related to fixed-interval size in 4 of 8 subjects, and in all subjects occurred consistently sooner in the progressive-schedule sequence under reset than under no-reset procedures. The latter result was replicated in a second experiment, in which choices between progressive- and fixed-interval schedules were compared with choices between progressive- and fixed-time schedules. In Experiment 3, switching patterns under reset conditions were unrelated to variations in intertrial interval. In none of the experiments did orderly choice patterns depend on verbal descriptions of the contingencies or on schedule-controlled response patterns in the presence of the chosen schedules. The overall pattern of results indicates control of choices by temporarily remote consequences, and is consistent with versions of optimality theory that address performance in situations of diminishing returns. PMID:8315364

  7. Evaluation of Advanced Microwave Landing System Procedures in the New York Terminal Area

    DTIC Science & Technology

    1991-03-01

    sector controller called the CAMRN sector who must then sequence that traffic with multiple feeders from the south before handing off to the final...Right (13R) were all being used by landing traffic, the final controller handled the runway 22 arrivals and the CAMRN controller handled the runway 13R...Feeder Fix AAL678 DC10 H 00:09:00 AAL68 B767 H 00:23:00 AAL588 A300 H 00:27:00 PAA224 A300 H 01:20:00 4/ TWAll L101 H 01:34:00 CAMRN Feeder Fix DAL144

  8. A k-permutation algorithm for Fixed Satellite Service orbital allotments

    NASA Technical Reports Server (NTRS)

    Reilly, Charles H.; Mount-Campbell, Clark A.; Gonsalvez, David J. A.

    1988-01-01

    A satellite system synthesis problem, the satellite location problem (SLP), is addressed in this paper. In SLP, orbital locations (longitudes) are allotted to geostationary satellites in the Fixed Satellite Service. A linear mixed-integer programming model is presented that views SLP as a combination of two problems: (1) the problem of ordering the satellites and (2) the problem of locating the satellites given some ordering. A special-purpose heuristic procedure, a k-permutation algorithm, that has been developed to find solutions to SLPs formulated in the manner suggested is described. Solutions to small example problems are presented and analyzed.

  9. Successful two-stage correction of ventricular septal defect and patent ductus arteriosus in a patient with fixed pulmonary hypertension.

    PubMed

    Pac, Aysenur; Polat, Tugcin Bora; Vural, Kerem; Pac, Mustafa

    2010-01-01

    We report a case of a 6-year-old boy with fixed severe pulmonary artery hypertension secondary to a ventricular septal defect (VSD) together with a patent ductus arteriosus (PDA). As a preliminary step, PDA embolization was performed following therapy with inhaled prostacyclin over a period of 6 months. Further, the patient underwent successful surgical VSD closure. We postulate that a staged procedure with long-term prostaglandin therapy might be capable of reducing pulmonary artery resistance and permitting total correction in a patient once considered to have inoperable pulmonary arteriopathy.

  10. Gauge fixing in higher-derivative gravity

    NASA Astrophysics Data System (ADS)

    Bartoli, A.; Julve, J.; Sánchez, E. J.

    1999-07-01

    Linearized 4-derivative gravity with a general gauge-fixing term is considered. By a Legendre transform and a suitable diagonalization procedure it is cast into a second-order equivalent form where the nature of the physical degrees of freedom, the gauge ghosts, the Weyl ghosts and the intriguing `third ghosts', characteristic to higher-derivative theories, is made explicit. The symmetries of the theory and the structure of the compensating Faddeev-Popov ghost sector exhibit non-trivial peculiarities. The unitarity breaking negative-norm Weyl ghosts, already present in the diff-invariant theory, are out of the reach of the ghost cancellation BRST mechanism.

  11. Year-long continuous personal exposure to PM 2.5 recorded by a fast responding portable nephelometer

    NASA Astrophysics Data System (ADS)

    Braniš, Martin; Kolomazníková, Jana

    2010-08-01

    Personal exposure to particulate matter of aerodynamic diameter under 2.5 μm (PM 2.5) was monitored using a DustTrak nephelometer. The battery-operated unit, worn by an adult individual for a period of approximately one year, logged integrated average PM 2.5 concentrations over 5 min intervals. A detailed time-activity diary was used to record the experimental subject's movement and the microenvironments visited. Altogether 239 days covering all the months (except April) were available for the analysis. In total, 60 463 acceptable 5-min averages were obtained. The dataset was divided into 7 indoor and 4 outdoor microenvironments. Of the total time, 84% was spent indoors, 10.9% outdoors and 5.1% in transport. The indoor 5-min PM 2.5 average was higher (55.7 μg m -3) than the outdoor value (49.8 μg m -3). The highest 5-min PM 2.5 average concentration was detected in restaurant microenvironments (1103 μg m -3), the second highest 5-min average concentration was recorded in indoor spaces heated by stoves burning solid fuels (420 μg m -3). The lowest 5-min mean aerosol concentrations were detected outdoors in rural/natural environments (25 μg m -3) and indoors at the monitored person's home (36 μg m -3). Outdoor and indoor concentrations of PM 2.5 measured by the nephelometer at home and during movement in the vicinity of the experimental subject's home were compared with those of the nearest fixed-site monitor of the national air quality monitoring network. The high correlation coefficient (0.78) between the personal and fixed-site monitor aerosol concentrations suggested that fixed-site monitor data can be used as proxies for personal exposure in residential and some other microenvironments. Collocated measurements with a reference method (β-attenuation) showed a non-linear systematic bias of the light-scattering method, limiting the use of direct concentration readings for exact exposure analysis.

  12. Numerical pricing of options using high-order compact finite difference schemes

    NASA Astrophysics Data System (ADS)

    Tangman, D. Y.; Gopaul, A.; Bhuruth, M.

    2008-09-01

    We consider high-order compact (HOC) schemes for quasilinear parabolic partial differential equations to discretise the Black-Scholes PDE for the numerical pricing of European and American options. We show that for the heat equation with smooth initial conditions, the HOC schemes attain clear fourth-order convergence but fail if non-smooth payoff conditions are used. To restore the fourth-order convergence, we use a grid stretching that concentrates grid nodes at the strike price for European options. For an American option, an efficient procedure is also described to compute the option price, Greeks and the optimal exercise curve. Comparisons with a fourth-order non-compact scheme are also done. However, fourth-order convergence is not experienced with this strategy. To improve the convergence rate for American options, we discuss the use of a front-fixing transformation with the HOC scheme. We also show that the HOC scheme with grid stretching along the asset price dimension gives accurate numerical solutions for European options under stochastic volatility.

  13. Method for determination of small amounts of rare earths and thorium in phosphate rocks

    USGS Publications Warehouse

    Waring, C.L.; Mela, H.

    1953-01-01

    In laboratory investigations, interest developed in the possible rare-earth content of phosphate samples from Florida and the northwestern United States. Because of the difficulty of making chemical determinations of traces of individual rare earths, a combined chemical-spectrographic method was investigated. After removal of iron by the extraction of the chloride with ether, the rare earths and thorium are concentrated by double oxalate precipitation, using calcium as a carrier. The rare earths are freed from calcium by an ammonium hydroxide precipitation with a fixed amount of aluminum as a carrier. The aluminum also serves as an internal standard in the final spectrographic analysis. The method will determine from 0.02 to 2 mg. of each rare earth with an error no greater than 10%. The investigation has resulted in a fairly rapid and precise procedure, involving no special spectrographic setup. The method could be applied to other types of geologic materials with the same expected accuracy.

  14. Design Considerations of a Transverse Flux Machine for Direct-Drive Wind Turbine Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Husain, Tausif; Hasan, Iftekhar; Sozer, Yilmaz

    This paper presents the design considerations of a double-sided transverse flux machine (TFM) for direct-drive wind turbine applications. The proposed TFM has a modular structure with quasi-U stator cores and toroidal ring windings. The rotor is constructed with ferrite magnets in a flux-concentrating setup to achieve high air gap flux density. Pole number selection is critical in the design process of a TFM as it affects both the torque density and power factor under fixed magnetic and changing electrical loading. Several key design ratios are introduced to facilitate the initial design procedure. The effect of pole shaping on back-EMF andmore » inductance is also analyzed. These investigations provide guidance toward the required design of a TFM for direct-drive applications. The analyses are carried out using analytical and three-dimensional finite element analysis (FEA). A proof-of-concept prototype was developed to experimentally validate the FEA results.« less

  15. Design Considerations of a Transverse Flux Machine for Direct-Drive Wind Turbine Applications

    DOE PAGES

    Husain, Tausif; Hasan, Iftekhar; Sozer, Yilmaz; ...

    2018-03-12

    This paper presents the design considerations of a double-sided transverse flux machine (TFM) for direct-drive wind turbine applications. The proposed TFM has a modular structure with quasi-U stator cores and toroidal ring windings. The rotor is constructed with ferrite magnets in a flux-concentrating setup to achieve high air gap flux density. Pole number selection is critical in the design process of a TFM as it affects both the torque density and power factor under fixed magnetic and changing electrical loading. Several key design ratios are introduced to facilitate the initial design procedure. The effect of pole shaping on back-EMF andmore » inductance is also analyzed. These investigations provide guidance toward the required design of a TFM for direct-drive applications. The analyses are carried out using analytical and three-dimensional finite element analysis (FEA). A proof-of-concept prototype was developed to experimentally validate the FEA results.« less

  16. Ionic liquid-based single-drop microextraction/gas chromatographic/mass spectrometric determination of benzene, toluene, ethylbenzene and xylene isomers in waters.

    PubMed

    Aguilera-Herrador, Eva; Lucena, Rafael; Cárdenas, Soledad; Valcárcel, Miguel

    2008-08-01

    The direct coupling between ionic liquid-based single-drop microextraction and gas chromatography/mass spectrometry is proposed for the rapid and simple determination of benzene, toluene, ethylbenzene and xylenes isomers (BTEX) in water samples. The extraction procedure exploits not only the high affinity of the selected ionic liquid (1-methyl-3-octyl-imidazolium hexaflourophosphate) to these aromatic compounds but also its special properties like viscosity, low vapour pressure and immiscibility with water. All the variables involved in the extraction process have been studied in depth. The developed method allows the determination of these single-ring compounds in water under the reference concentration level fixed by the international legislation. In this case, limits of detection were in the range 20 ng L(-1) (obtained for benzene) and 91 ng L(-1) (for o-xylene). The repeatability of the proposed method, expressed as RSD (n=5), varied between 3.0% (o-xylene) and 5.2% (toluene).

  17. Carbon bed mercury emissions control for mixed waste treatment.

    PubMed

    Soelberg, Nick; Enneking, Joe

    2010-11-01

    Mercury has various uses in nuclear fuel reprocessing and other nuclear processes, and so it is often present in radioactive and mixed (radioactive and hazardous) wastes. Compliance with air emission regulations such as the Hazardous Waste Combustor (HWC) Maximum Achievable Control Technology (MACT) standards can require off-gas mercury removal efficiencies up to 99.999% for thermally treating some mixed waste streams. Test programs have demonstrated this level of off-gas mercury control using fixed beds of granular sulfur-impregnated activated carbon. Other results of these tests include (1) the depth of the mercury control mass transfer zone was less than 15-30 cm for the operating conditions of these tests; (2) MERSORB carbon can sorb mercury up to 19 wt % of the carbon mass; and (3) the spent carbon retained almost all (98.3-99.99%) of the mercury during Toxicity Characteristic Leachability Procedure (TCLP) tests, but when even a small fraction of the total mercury dissolves, the spent carbon can fail the TCLP test when the spent carbon contains high mercury concentrations.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Husain, Tausif; Hasan, Iftekhar; Sozer, Yilmaz

    This paper presents the design considerations of a double-sided transverse flux machine (TFM) for direct-drive wind turbine applications. The TFM has a modular structure with quasi-U stator cores and ring windings. The rotor is constructed with ferrite magnets in a flux-concentrating arrangement to achieve high air gap flux density. The design considerations for this TFM with respect to initial sizing, pole number selection, key design ratios, and pole shaping are presented in this paper. Pole number selection is critical in the design process of a TFM because it affects both the torque density and power factor under fixed magnetic andmore » changing electrical loading. Several key design ratios are introduced to facilitate the design procedure. The effect of pole shaping on back-emf and inductance is also analyzed. These investigations provide guidance toward the required design of a TFM for direct-drive applications. The analyses are carried out using analytical and three-dimensional finite element analysis. A prototype is under construction for experimental verification.« less

  19. TiO2-photocatalyzed As(III) oxidation in a fixed-bed, flow-through reactor.

    PubMed

    Ferguson, Megan A; Hering, Janet G

    2006-07-01

    Compliance with the U.S. drinking water standard for arsenic (As) of 10 microg L(-1) is required in January 2006. This will necessitate implementation of treatment technologies for As removal by thousands of water suppliers. Although a variety of such technologies is available, most require preoxidation of As(III) to As(V) for efficient performance. Previous batch studies with illuminated TiO2 slurries have demonstrated that TiO2-photocatalyzed AS(III) oxidation occurs rapidly. This study examined reaction efficiency in a flow-through, fixed-bed reactor that provides a better model for treatment in practice. Glass beads were coated with mixed P25/sol gel TiO2 and employed in an upflow reactor irradiated from above. The reactor residence time, influent As(III) concentration, number of TiO2 coatings on the beads, solution matrix, and light source were varied to characterize this reaction and determine its feasibility for water treatment. Repeated usage of the same beads in multiple experiments or extended use was found to affect effluent As(V) concentrations but not the steady-state effluent As(III) concentration, which suggests that As(III) oxidation at the TiO2 surface undergoes dynamic sorption equilibration. Catalyst poisoning was not observed either from As(V) or from competitively adsorbing anions, although the higher steady-state effluent As(III) concentrations in synthetic groundwater compared to 5 mM NaNO3 indicated that competitive sorbates in the matrix partially hinder the reaction. A reactive transport model with rate constants proportional to incident light at each bead layer fit the experimental data well despite simplifying assumptions. TiO2-photocatalyzed oxidation of As(III) was also effective under natural sunlight. Limitations to the efficiency of As(III) oxidation in the fixed-bed reactor were attributable to constraints of the reactor geometry, which could be overcome by improved design. The fixed-bed TiO2 reactor offers an environmentally benign method for As(III) oxidation.

  20. Novel determinants of the neuronal Cl− concentration

    PubMed Central

    Delpire, Eric; Staley, Kevin J

    2014-01-01

    It is now a well-accepted view that cation-driven Cl− transporters in neurons are involved in determining the intracellular Cl− concentration. In the present review, we propose that additional factors, which are often overlooked, contribute substantially to the Cl− gradient across neuronal membranes. After briefly discussing the data supporting and opposing the role of cation–chloride cotransporters in regulating Cl−, we examine the participation of the following factors in the formation of the transmembrane Cl− gradient: (i) fixed ‘Donnan’ charges inside and outside the cell; (ii) the properties of water (free vs. bound); and (iii) water transport through the cotransporters. We demonstrate a steep relationship between intracellular Cl− and the concentration of fixed negative charges on macromolecules. We show that in the absence of water transport through the K+–Cl− cotransporter, a large osmotic gradient builds at concentrations below or above a set value of ‘Donnan’ charges, and show that at any value of these fixed charges, the reversal potential for Cl− equates that of K+. When the movement of water across the membrane is a source of free energy, it is sufficient to modify the movement of Cl− through the cotransporter. In this scenario, the reversal potential for Cl− does not closely follow that of K+. Furthermore, our simulations demonstrate that small differences in the availability of freely diffusible water between inside and outside the cell greatly affect the Cl− reversal potential, particularly when osmolar transmembrane gradients are minimized, for example by idiogenic osmoles. We also establish that the presence of extracellular charges has little effect on the chloride reversal potential, but greatly affects the effective inhibitory conductance for Cl−. In conclusion, our theoretical analysis of the presence of fixed anionic charges and water bound on macromolecules inside and outside the cell greatly impacts both Cl− gradient and Cl− conductance across neuronal membranes. PMID:25107928

  1. Volatile organic compound adsorption in a gas-solid fluidized bed.

    PubMed

    Ng, Y L; Yan, R; Tsen, L T S; Yong, L C; Liu, M; Liang, D T

    2004-01-01

    Fluidization finds many process applications in the areas of catalytic reactions, drying, coating, combustion, gasification and microbial culturing. This work aims to compare the dynamic adsorption characteristics and adsorption rates in a bubbling fluidized bed and a fixed bed at the same gas flow-rate, gas residence time and bed height. Adsorption with 520 ppm methanol and 489 ppm isobutane by the ZSM-5 zeolite of different particle size in the two beds enabled the differentiation of the adsorption characteristics and rates due to bed type, intraparticle mass transfer and adsorbate-adsorbent interaction. Adsorption of isobutane by the more commonly used activated carbon provided the comparison of adsorption between the two adsorbent types. With the same gas residence time of 0.79 seconds in both the bubbling bed and fixed bed of the same bed size of 40 mm diameter and 48 mm height, the experimental results showed a higher rate of adsorption in the bubbling bed as compared to the fixed bed. Intraparticle mass transfer and adsorbent-adsorbate interaction played significant roles in affecting the rate of adsorption, with intraparticle mass transfer being more dominant. The bubbling bed was observed to have a steeper decline in adsorption rate with respect to increasing outlet concentration compared to the fixed bed. The adsorption capacities of zeolite for the adsorbates studied were comparatively similar in both beds; fluidizing, and using smaller particles in the bubbling bed did not increase the adsorption capacity of the ZSM-5 zeolite. The adsorption capacity of activated carbon for isobutane was much higher than the ZSM-5 zeolite for isobutane, although at a lower adsorption rate. Fourier transform infra-red (FTIR) spectroscopy was used as an analytical tool for the quantification of gas concentration. Calibration was done using a series of standards prepared by in situ dilution with nitrogen gas, based on the ideal gas law and relating partial pressure to gas concentration. Concentrations up to 220 ppm for methanol and 75 ppm for isobutane were prepared using this method.

  2. Vaccine supply: a cross-national perspective.

    PubMed

    Danzon, Patricia M; Pereira, Nuno Sousa; Tejwani, Sapna S

    2005-01-01

    In U.S. vaccine markets, competing producers with high fixed, sunk costs face relatively concentrated demand. This tends to lead to exit of all but one or very few producers per vaccine. Detailed evidence of exits and shortages in the flu vaccine market demonstrates the importance of high fixed costs, demand uncertainty, and dynamic quality competition. A comparison of vaccine suppliers in four industrialized countries compared with the United States shows that smaller foreign markets often have more and different vaccine suppliers. High, country-specific, fixed costs, combined with price and volume uncertainty, plausibly deters these potential suppliers from attempting to enter the U.S. market.

  3. The Effect of Structural Curvings on the Stress Distribution in a Rigidly Fixed Composite Plate under Forced Vibration

    NASA Astrophysics Data System (ADS)

    Zamanov, A. D.

    2002-01-01

    Based on the exact three-dimensional equations of continuum mechanics and the Akbarov-Guz' continuum theory, the problem on forced vibrations of a rectangular plate made of a composite material with a periodically curved structure is formulated. The plate is rigidly fixed along the Ox 1 axis. Using the semi-analytic method of finite elements, a numerical procedure is elaborated for investigating this problem. The numerical results on the effect of structural curvings on the stress distribution in the plate under forced vibrations are analyzed. It is shown that the disturbances of the stress σ22 in a hinge-supported plate are greater than in a rigidly fixed one. Also, it is found that the structural curvings considerably affect the stress distribution in plates both under static and dynamic loading.

  4. Dual jaw treatment of edentulism using implant-supported monolithic zirconia fixed prostheses.

    PubMed

    Altarawneh, Sandra; Limmer, Bryan; Reside, Glenn J; Cooper, Lyndon

    2015-01-01

    This case report describes restoration of the edentulous maxilla and mandible with implant supported fixed prostheses using monolithic zirconia, where the incisal edges and occluding surfaces were made of monolithic zirconia. Edentulism is a debilitating condition that can be treated with either a removable or fixed dental prosthesis. The most common type of implant-supported fixed prosthesis is the metal acrylic (hybrid), with ceramo-metal prostheses being used less commonly in complete edentulism. However, both of these prostheses designs are associated with reported complications of screw loosening or fracture and chipping of acrylic resin and porcelain. Monolithic zirconia implant-supported fixed prostheses have the potential for reduction of such complications. In this case, the CAD/CAM concept was utilized in fabrication of maxillary and mandibular screw-retained implant-supported fixed prostheses using monolithic zirconia. Proper treatment planning and execution coupled with utilizing advanced technologies contributes to highly esthetic results. However, long-term studies are required to guarantee a satisfactory long-term outcome of this modality of treatment. This case report describes the clinical and technical procedures involved in fabrication of maxillary and mandibular implant-supported fixed prostheses using monolithic zirconia as a treatment of edentulism, and proposes the possible advantages associated with using monolithic zirconia in eliminating dissimilar interfaces in such prostheses that are accountable for the most commonly occurring technical complication for these prostheses being chipping and fracture of the veneering material. © 2015 Wiley Periodicals, Inc.

  5. Robotic platform for parallelized cultivation and monitoring of microbial growth parameters in microwell plates.

    PubMed

    Knepper, Andreas; Heiser, Michael; Glauche, Florian; Neubauer, Peter

    2014-12-01

    The enormous variation possibilities of bioprocesses challenge process development to fix a commercial process with respect to costs and time. Although some cultivation systems and some devices for unit operations combine the latest technology on miniaturization, parallelization, and sensing, the degree of automation in upstream and downstream bioprocess development is still limited to single steps. We aim to face this challenge by an interdisciplinary approach to significantly shorten development times and costs. As a first step, we scaled down analytical assays to the microliter scale and created automated procedures for starting the cultivation and monitoring the optical density (OD), pH, concentrations of glucose and acetate in the culture medium, and product formation in fed-batch cultures in the 96-well format. Then, the separate measurements of pH, OD, and concentrations of acetate and glucose were combined to one method. This method enables automated process monitoring at dedicated intervals (e.g., also during the night). By this approach, we managed to increase the information content of cultivations in 96-microwell plates, thus turning them into a suitable tool for high-throughput bioprocess development. Here, we present the flowcharts as well as cultivation data of our automation approach. © 2014 Society for Laboratory Automation and Screening.

  6. A High Precision Approach to Calibrate a Structured Light Vision Sensor in a Robot-Based Three-Dimensional Measurement System.

    PubMed

    Wu, Defeng; Chen, Tianfei; Li, Aiguo

    2016-08-30

    A robot-based three-dimensional (3D) measurement system is presented. In the presented system, a structured light vision sensor is mounted on the arm of an industrial robot. Measurement accuracy is one of the most important aspects of any 3D measurement system. To improve the measuring accuracy of the structured light vision sensor, a novel sensor calibration approach is proposed to improve the calibration accuracy. The approach is based on a number of fixed concentric circles manufactured in a calibration target. The concentric circle is employed to determine the real projected centres of the circles. Then, a calibration point generation procedure is used with the help of the calibrated robot. When enough calibration points are ready, the radial alignment constraint (RAC) method is adopted to calibrate the camera model. A multilayer perceptron neural network (MLPNN) is then employed to identify the calibration residuals after the application of the RAC method. Therefore, the hybrid pinhole model and the MLPNN are used to represent the real camera model. Using a standard ball to validate the effectiveness of the presented technique, the experimental results demonstrate that the proposed novel calibration approach can achieve a highly accurate model of the structured light vision sensor.

  7. Stitching-aware in-design DPT auto fixing for sub-20nm logic devices

    NASA Astrophysics Data System (ADS)

    Choi, Soo-Han; Sai Krishna, K. V. V. S.; Pemberton-Smith, David

    2017-03-01

    As the technology continues to shrink below 20nm, Double Patterning Technology (DPT) becomes one of the mandatory solutions for routing metal layers. From the view point of Place and Route (P&R), the major concerns are how to prevent DPT odd-cycles automatically without sacrificing chip area. Even though the leading-edge P&R tools have advanced algorithms to prevent DPT odd-cycles, it is very hard to prevent the localized DPT odd-cycles, especially in Engineering Change Order (ECO) routing. In the last several years, we developed In-design DPT Auto Fixing method in order to reduce localized DPT odd-cycles significantly during ECO and could achieve remarkable design Turn-Around Times (TATs). But subsequently, as the design complexity continued increasing and chip size continued decreasing, we needed a new In-design DPT Auto Fixing approach to improve the auto. fixing rate. In this paper, we present the Stitching-Aware In-design DPT Auto Fixing method for better fixing rates and smaller chip design. The previous In-design DPT Auto Fixing method detected all DPT odd-cycles and tried to remove oddcycles by increasing the adjacent space. As the metal congestions increase in the newer technology nodes, the older Auto Fixing method has limitations to increase the adjacent space between routing metals. Consequently, the auto fixing rate of older method gets worse with the introduction of the smaller design rules. With DPT stitching enablement at In-design DRC checking procedure, the new Stitching-Aware DPT Auto Fixing method detects the most critical odd-cycles and revolve the odd-cycles automatically. The accuracy of new flow ensures better usage of space in the congested areas, and helps design more smaller chips. By applying the Stitching-Aware DPT Auto Fixing method to sub-20nm logic devices, we can confirm that the auto fixing rate is improved by 2X compared with auto fixing without stitching. Additionally, by developing the better heuristic algorithm and flow for DPT stitching, we can get DPT compliant layout with the acceptable design TATs.

  8. Sedation-analgesia with propofol and remifentanil: concentrations required to avoid gag reflex in upper gastrointestinal endoscopy.

    PubMed

    Borrat, Xavier; Valencia, José Fernando; Magrans, Rudys; Gimenez-Mila, Marc; Mellado, Ricard; Sendino, Oriol; Perez, Maria; Nunez, Matilde; Jospin, Mathieu; Jensen, Erik Weber; Troconiz, Inaki; Gambus, Pedro L

    2015-07-01

    The purpose of this study was to identify optimal target propofol and remifentanil concentrations to avoid a gag reflex in response to insertion of an upper gastrointestinal endoscope. Patients presenting for endoscopy received target-controlled infusions (TCI) of both propofol and remifentanil for sedation-analgesia. Patients were randomized to 4 groups of fixed target effect-site concentrations: remifentanil 1 ng•mL (REMI 1) or 2 ng•mL (REMI 2) and propofol 2 μg•mL (PROP 2) or 3 μg•mL (PROP 3). For each group, the other drug (propofol for the REMI groups and vice versa) was increased or decreased using the "up-down" method based on the presence or absence of a gag response in the previous patient. A modified isotonic regression method was used to estimate the median effective Ce,50 from the up-down method in each group. A concentration-effect (sigmoid Emax) model was built to estimate the corresponding Ce,90 for each group. These data were used to estimate propofol bolus doses and remifentanil infusion rates that would achieve effect-site concentrations between Ce,50 and Ce,90 when a TCI system is not available for use. One hundred twenty-four patients were analyzed. To achieve between a 50% and 90% probability of no gag response, propofol TCIs were between 2.40 and 4.23 μg•mL (that could be achieved with a bolus of 1 mg•kg) when remifentanil TCI was fixed at 1 ng•mL, and target propofol TCIs were between 2.15 and 2.88 μg•mL (that could be achieved with a bolus of 0.75 mg•kg) when remifentanil TCI was fixed at 2 ng•mL. Remifentanil ranges were 1.00 to 4.79 ng•mL and 0.72 to 3.19 ng•mL when propofol was fixed at 2 and 3 μg•mL, respectively. We identified a set of propofol and remifentanil TCIs that blocked the gag response to endoscope insertion in patients undergoing endoscopy. Propofol bolus doses and remifentanil infusion rates designed to achieve similar effect-site concentrations can be used to prevent gag response when TCI is not available.

  9. Water-quality assessment of the Kentucky River Basin, Kentucky; distribution of metals and other trace elements in sediment and water, 1987-90

    USGS Publications Warehouse

    Porter, Stephen D.; White, Kevin D.; Clark, J.R.

    1995-01-01

    The U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) Program is designed to provide a nationally consistent description of the current status of water quality, to define water-quality trends, and to relate past and present water-quality conditions to natural features, uses of land and water, and other water-quality effects from human activities. The Kentucky River Basin is one of four NAWQA pilot projects that focused primarily on the quality of surface water. Water, sediment, and bedrock samples were collected in the Kentucky River Basin during 1987-90 for the purpose of (1) describing the spatial distribution, transport, and temporal variability of metals and other trace elements in streams of the basin; (2) estimating mean annual loads, yields, and trends of constituent concentrations and identifying potential causes (or sources) of spatial patterns; (3) providing baseline information for concentrations of metals in streambed and suspended sediments; (4) identifying stream reaches in the Kentucky River Basin with chronic water-quality problems; and (5) evaluating the merits of the NAWQA pilot study-approach for the assessment of metals and other trace elements in a river system. The spatial distribution of metals and other trace elements in streambed sediments of the Kentucky River Basin is associated with regional differences of geology, land use and cover, and the results of human activities. Median concentrations of constituents differed significantly among physiographic regions of the basin because of relations to bedrock geochemistry and land disturbance. Concentrations of potentially toxic metals were large in urban and industrial areas of the basin. Elevated concentrations of certain metals were also found in streambed sediments of the Knobs Region because of the presence of Devonian shale bedrock. Elevated concentrations of lead and zinc found in streambed sediments of the Bluegrass Region are likely associated with urban stormwater runoff, point-source discharges, and waste-management practices. Concentrations of cadmium, chromium, copper, mercury, and silver were elevated in streambed sediments downstream from wastewater-treatment plant discharges. Streambed-sediment concentrations of barium, chromium, and lithium were elevated in streams that receive brine discharges from oil production. Elevated concentrations of antimony, arsenic, molybdenum, selenium, strontium, uranium, and vanadium in streambed sediments of the Kentucky River Basin were generally associated with natural sources. Concentrations of metals and other trace elements in water samples from fixed stations (stations where water-quality samples were collected for 3.5 years) in the Kentucky River Basin were generally related to stream discharge and the concentration of suspended sediment, whereas constituent concentrations in the suspended-sediment matrix were indicative of natural and human sources. Estimated mean annual loads and yields for most metals and other trace elements were associated with the transport of suspended sediment. Land disturbance, such as surface mining and agriculture, contribute to increased transport of sediment in streams, thereby increasing concentrations of metals in water samples during periods of intense or prolonged rainfall and increased stream discharge. Concentrations of many metals and trace elements were reduced during low streamflow. Although total-recoverable and dissolved concentrations of certain metals and trace elements were large in streams affected by land disturbance, concentrations of constituents in the suspendedsediment matrix were commonly large in streams in the Knobs and Eastern Coal Field Regions (because of relations with bedrock geochemistry) and in streams that receive wastewater or oil-well-brine discharges. Concentrations and mean annual load estimates for aluminum, chromium, copper, iron, lead, manganese, and mercury were larger than those obtained from data collected by a State agency, probably because of differences in sample-collection methodology, the range of discharge associated with water-quality samples, and laboratory analytical procedures. However, concentrations, loads, and yields of arsenic, barium, and zinc were similar to those determined from the State data. Significant upward trends in the concentrations of aluminum, iron, magnesium, manganese, and zinc were indicated at one or more fixed stations in the Kentucky River Basin during the past 10 to 15 years. Upward trends for concentrations of aluminum, iron, and manganese were found at sites that receive drainage from coal mines in the upper Kentucky River Basin, whereas upward trends for zinc may be associated with urban sources. Water-quality criteria established by the U.S. Environmental Protection Agency (USEPA) or the State of Kentucky for concentrations of aluminum, beryllium, cadmium, chromium, copper, iron, manganese, nickel, silver, and zinc were exceeded at one or more fixed stations in the Kentucky River Basin. On a qualitative basis, dissolved concentrations of certain metals and trace elements were large during low streamflow at sites where (1) concentrations of these constituents in underlying streambed sediments were large, or (2) dissolvedoxygen concentrations were small. Concentrations of barium, lithium, and strontium were large during low streamflow, which indicates the influence of ground-water baseflows on the quality of surface water during low flow. The effects of point-source discharges, landfills, and other wastemanagement practices are somewhat localized in the Kentucky River Basin and are best indicated by the spatial distribution of metals and other trace elements in streambed sediments and in the suspended-sediment fraction of water samples at stream locations near the source. It was not possible to quantify the contribution of point sources to the total transport of metals and other trace elements at fixed stations because data were not available for wastewater effluents. Quantification of baseline concentrations of metals and other trace elements in streambed sediments provides a basis for the detection of water-quality changes that may result from improvements in wastewater treatment or the implementation of best-management practices for controlling contamination from nonpoint sources in the Kentucky River Basin.

  10. Belowground microbial processes underpin forest productivity.

    Treesearch

    C.Y. Li; E. Strzelczyk

    2002-01-01

    Nitrogen-fixing bacteria associated with mycorrhizal fungi and mycorrhizas can be demonstrated with microaerophilic procedures. The chemical substrates in mycorrhizal fungi or mycorrhizas often stimulate the growth and nitrogenase activity of the associated N2 fixers. In addition, the associated N2 fixers are producers of...

  11. 21 CFR 1315.23 - Procedure for fixing individual manufacturing quotas.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) The economic and physical availability of raw materials for use in manufacturing and for inventory purposes, (iv) Yield and stability problems, (v) Potential disruptions to production (including possible... cycle and current inventory position. (iii) The economic and physical availability of raw materials for...

  12. 48 CFR 48.104-2 - Sharing acquisition savings.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... CONTRACT MANAGEMENT VALUE ENGINEERING Policies and Procedures 48.104-2 Sharing acquisition savings. (a... value engineering clause or alternate used, and the type of savings, as follows: Government/Contractor... percent for fixed-price contracts; or (2) 75 percent for cost-reimbursement contracts. Value engineering...

  13. 47 CFR 101.1101 - LMDS service subject to competitive bidding.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false LMDS service subject to competitive bidding. 101.1101 Section 101.1101 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS § 101.1101 LMDS...

  14. 47 CFR 101.1101 - LMDS service subject to competitive bidding.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false LMDS service subject to competitive bidding. 101.1101 Section 101.1101 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS § 101.1101 LMDS...

  15. 47 CFR 101.1102-101.1105 - [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false [Reserved] 101.1102-101.1105 Section 101.1102-101.1105 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS §§ 101.1102-101.1105 [Reserved] ...

  16. 47 CFR 101.1101 - LMDS service subject to competitive bidding.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false LMDS service subject to competitive bidding. 101.1101 Section 101.1101 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS § 101.1101 LMDS...

  17. 47 CFR 101.1102-101.1105 - [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false [Reserved] 101.1102-101.1105 Section 101.1102-101.1105 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS §§ 101.1102-101.1105 [Reserved] ...

  18. 47 CFR 101.1101 - LMDS service subject to competitive bidding.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false LMDS service subject to competitive bidding. 101.1101 Section 101.1101 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS § 101.1101 LMDS...

  19. 47 CFR 101.1101 - LMDS service subject to competitive bidding.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false LMDS service subject to competitive bidding. 101.1101 Section 101.1101 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS § 101.1101 LMDS...

  20. 47 CFR 101.1102-101.1105 - [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false [Reserved] 101.1102-101.1105 Section 101.1102-101.1105 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Competitive Bidding Procedures for LMDS §§ 101.1102-101.1105 [Reserved] ...

  1. 48 CFR 16.601 - Time-and-materials contracts.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... awarded without adequate price competition (see 15.403-1(c)(1)), the contract shall specify separate fixed...-Commercial Item Acquisitions With Adequate Price Competition, in solicitations contemplating use of a Time... based on adequate price competition. If authorized by agency procedures, the contracting officer may...

  2. Comparison between variable and fixed dwell-time PN acquisition algorithms. [for synchronization in pseudonoise spread spectrum systems

    NASA Technical Reports Server (NTRS)

    Braun, W. R.

    1981-01-01

    Pseudo noise (PN) spread spectrum systems require a very accurate alignment between the PN code epochs at the transmitter and receiver. This synchronism is typically established through a two-step algorithm, including a coarse synchronization procedure and a fine synchronization procedure. A standard approach for the coarse synchronization is a sequential search over all code phases. The measurement of the power in the filtered signal is used to either accept or reject the code phase under test as the phase of the received PN code. This acquisition strategy, called a single dwell-time system, has been analyzed by Holmes and Chen (1977). A synopsis of the field of sequential analysis as it applies to the PN acquisition problem is provided. From this, the implementation of the variable dwell time algorithm as a sequential probability ratio test is developed. The performance of this algorithm is compared to the optimum detection algorithm and to the fixed dwell-time system.

  3. The augmentation algorithm and molecular phylogenetic trees

    NASA Technical Reports Server (NTRS)

    Holmquist, R.

    1978-01-01

    Moore's (1977) augmentation procedure is discussed, and it is concluded that the procedure is valid for obtaining estimates of the total number of fixed nucleotide substitutions both theoretically and in practice, for both simulated and real data, and in agreement, for experimentally dense data sets, with stochastic estimates of the divergence, provided the restrictions on codon mutability resulting from natural selection are explicitly allowed for. Tateno and Nei's (1978) critique that the augmentation procedure has a systematic bias toward overestimation of the total number of nucleotide replacements is disputed, and a data analysis suggests that ancestral sequences inferred by the method of parsimony contain a large number of incorrectly assigned nucleotides.

  4. Kinetic modeling and exploratory numerical simulation of chloroplastic starch degradation

    PubMed Central

    2011-01-01

    Background Higher plants and algae are able to fix atmospheric carbon dioxide through photosynthesis and store this fixed carbon in large quantities as starch, which can be hydrolyzed into sugars serving as feedstock for fermentation to biofuels and precursors. Rational engineering of carbon flow in plant cells requires a greater understanding of how starch breakdown fluxes respond to variations in enzyme concentrations, kinetic parameters, and metabolite concentrations. We have therefore developed and simulated a detailed kinetic ordinary differential equation model of the degradation pathways for starch synthesized in plants and green algae, which to our knowledge is the most complete such model reported to date. Results Simulation with 9 internal metabolites and 8 external metabolites, the concentrations of the latter fixed at reasonable biochemical values, leads to a single reference solution showing β-amylase activity to be the rate-limiting step in carbon flow from starch degradation. Additionally, the response coefficients for stromal glucose to the glucose transporter kcat and KM are substantial, whereas those for cytosolic glucose are not, consistent with a kinetic bottleneck due to transport. Response coefficient norms show stromal maltopentaose and cytosolic glucosylated arabinogalactan to be the most and least globally sensitive metabolites, respectively, and β-amylase kcat and KM for starch to be the kinetic parameters with the largest aggregate effect on metabolite concentrations as a whole. The latter kinetic parameters, together with those for glucose transport, have the greatest effect on stromal glucose, which is a precursor for biofuel synthetic pathways. Exploration of the steady-state solution space with respect to concentrations of 6 external metabolites and 8 dynamic metabolite concentrations show that stromal metabolism is strongly coupled to starch levels, and that transport between compartments serves to lower coupling between metabolic subsystems in different compartments. Conclusions We find that in the reference steady state, starch cleavage is the most significant determinant of carbon flux, with turnover of oligosaccharides playing a secondary role. Independence of stationary point with respect to initial dynamic variable values confirms a unique stationary point in the phase space of dynamically varying concentrations of the model network. Stromal maltooligosaccharide metabolism was highly coupled to the available starch concentration. From the most highly converged trajectories, distances between unique fixed points of phase spaces show that cytosolic maltose levels depend on the total concentrations of arabinogalactan and glucose present in the cytosol. In addition, cellular compartmentalization serves to dampen much, but not all, of the effects of one subnetwork on another, such that kinetic modeling of single compartments would likely capture most dynamics that are fast on the timescale of the transport reactions. PMID:21682905

  5. Seasonal and spatial variability of pesticides in streams of the upper Tennessee River basin, 1996-99

    USGS Publications Warehouse

    Treece, M.W.

    2003-01-01

    From 1996 to 1999, the U.S. Geological Survey conducted an assessment of pesticides in streams in the upper Tennessee River Basin (UTEN), which includes parts of Tennessee, North Carolina, Virginia, and Georgia. A total of 362 water samples were collected at 13 fixed surface-water sites from March 1996 through June 1999, and an additional 61 samples were collected throughout the UTEN during the spring and summers of 1996, 1997, and 1998. In 1996, 3 of the 13 fixed sites located in agricultural watersheds were sampled intensively (weekly) for about 8 months during the growing season. Water samples were analyzed for 85 herbicides, insecticides, and pesticide metabolites. Based on a threshold concentration of 0.01 microgram per liter, the most frequently detected herbicides were atrazine (59 percent); tebuthiuron (41 percent); the metabolite, deethylatrazine (31 percent); metolachlor (24 percent); simazine (17 percent); and prometon (6.4 percent). The insecticides detected most frequently were carbaryl (6.1 percent), diazinon (1.9 percent), carbofuran (1.7 percent), and chlorpyrifos (1.1 percent). Pesticide concentrations varied seasonally and were closely related to land use. The highest pesticide concentrations occurred in the agricultural watersheds in late spring and early summer (April through July), coinciding with pesticide application and the first substantial storm following pesticide application. Results of the spatial analysis of pesticides during base-flow conditions indicate that water-quality conditions at the fixed sites were representative of conditions in the upper Tennessee River Basin. Although most of the water samples collected in the upper Tennessee River Basin contained detectable concentrations of one or more pesticides, none of the concentrations exceeded any human health guidelines.

  6. Spectrophotometric techniques to determine tranexamic acid: Kinetic studies using ninhydrin and direct measuring using ferric chloride

    NASA Astrophysics Data System (ADS)

    Arayne, M. Saeed; Sultana, Najma; Siddiqui, Farhan Ahmed; Mirza, Agha Zeeshan; Zuberi, M. Hashim

    2008-11-01

    Two simple and sensitive spectrophotometric methods in ultraviolet and visible region are described for the determination of tranexamic acid in pure form and pharmaceutical preparations. The first method is based on the reaction of the drug with ninhydrin at boiling temperature and by measuring the increase in absorbance at 575 nm as a function of time. The initial rate, rate constant and fixed time (120 min) procedures were used for constructing the calibration graphs to determine the concentration of the drug, which showed a linear response over the concentration range 16-37 μg mL -1 with correlation coefficient " r" 0.9997, 0.996, 0.9999, LOQ 6.968, 7.138, 2.462 μgmL -1 and LOD 2.090, 2.141 and 0.739 μgmL -1, respectively. In second method tranexamic acid was reacted with ferric chloride solution, yellowish orange colored chromogen showed λ max at 375 nm showing linearity in the concentration range of 50-800 μg mL -1 with correlation coefficient " r" 0.9997, LOQ 6.227 μgmL -1 and LOD 1.868 μgmL -1. The variables affecting the development of the color were optimized and the developed methods were validated statistically and through recovery studies. These results were also verified by IR and NMR spectroscopy. The proposed methods have been successfully applied to the determination of tranexamic acid in commercial pharmaceutical formulation.

  7. Effects of oxytetracycline on the abundance and community structure of nitrogen-fixing bacteria during cattle manure composting.

    PubMed

    Sun, Jiajun; Qian, Xun; Gu, Jie; Wang, Xiaojuan; Gao, Hua

    2016-09-01

    The effects of oxytetracycline (OTC) on nitrogen-fixing bacterial communities were investigated during cattle manure composting. The abundance and community structure of nitrogen-fixing bacteria were determined by qPCR and denaturing gradient gel electrophoresis (DGGE), respectively. The matrix was spiked with OTC at four levels: no OTC, 10mg/kg dry weight (DW) OTC (L), 60mg/kg DW OTC (M), and 200mg/kg DW OTC (H). The high temperature period of composting was shorter with M and H, and the decline in temperature during the cooling stage was accelerated by OTC. OTC had a concentration-dependent inhibitory effect on the nitrogenase activity during early composting, and the nifH gene abundance declined significantly during the later composting stage. The DGGE profile and statistical analysis showed that OTC changed the nitrogen-fixing bacterial community succession and reduced the community richness and dominance. The nitrogen-fixing bacterial community structure was affected greatly by the high level of OTC. Copyright © 2016. Published by Elsevier Ltd.

  8. A review of the Fermilab fixed-target program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rameika, R.

    1994-12-01

    All eyes are now on the Fermilab collider program as the intense search for the top quark continues. Nevertheless, Fermilab`s long tradition of operating a strong, diverse physics program depends not only on collider physics but also on effective use of the facilities the Laboratory was founded on, the fixed-target beamlines. In this talk the author presents highlights of the Fermilab fixed-target program from its (not too distant) past, (soon to be) present, and (hopefully, not too distant) future program. The author concentrates on those experiments which are unique to the fixed-target program, in particular hadron structure measurements which usemore » the varied beams and targets available in this mode and the physics results from kaon, hyperon and high statistics charm experiments which are not easily accessible in high p{sub T} hadron collider detectors.« less

  9. Kinetic determination of propranolol in tablets by oxidation with ceric sulphate.

    PubMed

    Sultan, S M; Altamrah, S A; Aziz Alrahman, A M; Alzamil, I Z; Karrar, M O

    1989-01-01

    A simple and accurate kinetic method for the determination of propranolol has been developed. Cerium(IV) sulphate (0.5 M) is used to oxidize propranolol in 2 M sulphuric acid at room temperature to the ketone form that absorbs light at a lambda max of 525 nm. The fixed-concentration method is used by recording the exact time, t(s), taken for the reaction to reach a fixed absorbance of 0.100. The unknown concentration, c(M), of propranolol is calculated from the equation: l/t = 0 0.000217 + 0.03 c. The method has been applied to the determination of propranolol in proprietary tablets and the results were compared with those obtained by the B.P. and other standard methods.

  10. Using Concentration Curves to Assess Organization-Specific Relationships between Surgeon Volumes and Outcomes.

    PubMed

    Kanter, Michael H; Huang, Yii-Chieh; Kally, Zina; Gordon, Margo A; Meltzer, Charles

    2018-06-01

    A well-documented association exists between higher surgeon volumes and better outcomes for many procedures, but surgeons may be reluctant to change practice patterns without objective, credible, and near real-time data on their performance. In addition, published thresholds for procedure volumes may be biased or perceived as arbitrary; typical reports compare surgeons grouped into discrete procedure volume categories, even though the volume-outcomes relationship is likely continuous. The concentration curves methodology, which has been used to analyze whether health outcomes vary with socioeconomic status, was adapted to explore the association between procedure volume and outcomes as a continuous relationship so that data for all surgeons within a health care organization could be included. Using widely available software and requiring minimal analytic expertise, this approach plots cumulative percentages of two variables of interest against each other and assesses the characteristics of the resulting curve. Organization-specific relationships between surgeon volumes and outcomes were examined for three example types of procedures: uncomplicated hysterectomies, infant circumcisions, and total thyroidectomies. The concentration index was used to assess whether outcomes were equally distributed unrelated to volumes. For all three procedures, the concentration curve methodology identified associations between surgeon procedure volumes and selected outcomes that were specific to the organization. The concentration indices confirmed the higher prevalence of examined outcomes among low-volume surgeons. The curves supported organizational discussions about surgical quality. Concentration curves require minimal resources to identify organization- and procedure-specific relationships between surgeon procedure volumes and outcomes and can support quality improvement. Copyright © 2018 The Joint Commission. Published by Elsevier Inc. All rights reserved.

  11. Economic analysis of two-stage septic revision after total hip arthroplasty: What are the relevant costs for the hospital's orthopedic department?

    PubMed

    Kasch, R; Assmann, G; Merk, S; Barz, T; Melloh, M; Hofer, A; Merk, H; Flessa, S

    2016-03-01

    The number of septic total hip arthroplasty (THA) revisions is increasing continuously, placing a growing financial burden on hospitals. Orthopedic departments performing septic THA revisions have no basis for decision making regarding resource allocation as the costs of this procedure for the departments are unknown. It is widely assumed that septic THA procedures can only be performed at a loss for the department. Therefore, the purpose of this study was to investigate whether this assumption is true by performing a detailed analysis of the costs and revenues for two-stage septic THA revision. Patients who underwent revision THA for septic loosening in two sessions from January 2009 through March 2012 were included in this retrospective, consecutive cost study from the orthopedic department's point of view. We analyzed variable and case-fixed costs for septic revision THA with special regard to implantation and explantation stay. By using marginal costing approach we neglected hospital-fixed costs. Outcome measures include reimbursement and daily contribution margins. The average direct costs (reimbursement) incurred for septic two-stage revision THA was €10,828 (€24,201). The difference in cost and contribution margins per day was significant (p < .001 and p = 0.019) for ex- and implantation (€4147 vs. €6680 and €429 vs. €306) while length of stay and reimbursement were comparable. This is the first detailed analysis of the hospital department's cost for septic revision THA performed in two sessions. Disregarding hospital-fixed costs the included variable and case fixed-costs were covered by revenues. This study provides cost data, which will be guidance for health care decision makers.

  12. Co-C and Pd-C Fixed Points for the Evaluation of Facilities and Scales Realization at INRIM and NMC

    NASA Astrophysics Data System (ADS)

    Battuello, M.; Wang, L.; Girard, F.; Ang, S. H.

    2014-04-01

    Two hybrid cells for realizing the Co-C and Pd-C fixed points and constructed at Istituto Nazionale di Ricerca Metrologica (INRIM) were used for an evaluation of facilities and procedures adopted by INRIM and National Metrology Institute of Singapore (NMC) for the realization of the solid-liquid phase transitions of high-temperature fixed points and for determining their transition temperatures. Four different furnaces were used for the investigations, i.e., two single-zone furnaces, one of them of the direct-heating type, and two identical three-zone furnaces. The transition temperatures were measured at both institutes by adopting different procedures for realizing the radiation scales, i.e., at INRIM a scheme based on the extrapolation of fixed-point interpolated scales and an International Temperature Scale of 1990 (ITS-90) approach at NMC. The point of inflection (POI) of the melting curves was determined and assumed as a practical representation of the melting temperature. Different methods for deriving the POI were used, and differences as large as some hundredths of a kelvin were found with the different approaches. The POIs of the different melting curves were analyzed with respect to the different possible operative conditions with the aim of deriving reproducibility figures to improve the estimated uncertainty. As regard to the institutes inter-comparison, differences of 0.13 K and 0.29 K were found between INRIM and NMC determinations at the Co-C and Pd-C points, respectively. Such differences are compatible with the combined standard uncertainties of the comparison, which are estimated to be 0.33 K and 0.36 K at the Co-C and Pd-C points, respectively.

  13. Procedures for Behavioral Experiments in Head-Fixed Mice

    PubMed Central

    Guo, Zengcai V.; Hires, S. Andrew; Li, Nuo; O'Connor, Daniel H.; Komiyama, Takaki; Ophir, Eran; Huber, Daniel; Bonardi, Claudia; Morandell, Karin; Gutnisky, Diego; Peron, Simon; Xu, Ning-long; Cox, James; Svoboda, Karel

    2014-01-01

    The mouse is an increasingly prominent model for the analysis of mammalian neuronal circuits. Neural circuits ultimately have to be probed during behaviors that engage the circuits. Linking circuit dynamics to behavior requires precise control of sensory stimuli and measurement of body movements. Head-fixation has been used for behavioral research, particularly in non-human primates, to facilitate precise stimulus control, behavioral monitoring and neural recording. However, choice-based, perceptual decision tasks by head-fixed mice have only recently been introduced. Training mice relies on motivating mice using water restriction. Here we describe procedures for head-fixation, water restriction and behavioral training for head-fixed mice, with a focus on active, whisker-based tactile behaviors. In these experiments mice had restricted access to water (typically 1 ml/day). After ten days of water restriction, body weight stabilized at approximately 80% of initial weight. At that point mice were trained to discriminate sensory stimuli using operant conditioning. Head-fixed mice reported stimuli by licking in go/no-go tasks and also using a forced choice paradigm using a dual lickport. In some cases mice learned to discriminate sensory stimuli in a few trials within the first behavioral session. Delay epochs lasting a second or more were used to separate sensation (e.g. tactile exploration) and action (i.e. licking). Mice performed a variety of perceptual decision tasks with high performance for hundreds of trials per behavioral session. Up to four months of continuous water restriction showed no adverse health effects. Behavioral performance correlated with the degree of water restriction, supporting the importance of controlling access to water. These behavioral paradigms can be combined with cellular resolution imaging, random access photostimulation, and whole cell recordings. PMID:24520413

  14. Differential establishment and maintenance of oral ethanol reinforced behavior in Lewis and Fischer 344 inbred rat strains.

    PubMed

    Suzuki, T; George, F R; Meisch, R A

    1988-04-01

    Oral ethanol self-administration was investigated systematically in two inbred strains of rats, Fischer 344 CDF (F-344)/CRLBR (F344) and Lewis LEW/CRLBR (LEW). For both strains ethanol maintained higher response rates and was consumed in larger volumes than the water vehicle. In addition, blood ethanol levels increased with increases in ethanol concentration. However, LEW rats drank substantially more ethanol than F344 rats. The typical inverted U-shaped function between ethanol concentration and number of deliveries was observed for the LEW rats, whereas for the F344 rats much smaller differences were seen between ethanol and water maintained responding. For the LEW strain, as the fixed-ratio size was increased, the number of responses increased almost in direct proportion to the fixed-ratio size increase, so that at least at the lower fixed-ratio values the rats were obtaining similar numbers of deliveries at different fixed-ratio sizes. However, a decrease in ethanol deliveries and blood ethanol levels was observed at higher fixed-ratio sizes. Similar results were obtained in F344 rats, but the amount of responding was lower and less consistent. LEW rats showed significantly higher response rates, numbers of ethanol deliveries and blood ethanol levels. Ethanol-induced behavioral activation also was observed in LEW rats, but not in F344 rats. These results support the conclusion that ethanol serves as a strong positive reinforcer for LEW rats and as a weak positive reinforcer for F344 rats, and that genotype is a determinant of the degree to which ethanol functions as a reinforcer.

  15. Effect of precursor concentration and spray pyrolysis temperature upon hydroxyapatite particle size and density.

    PubMed

    Cho, Jung Sang; Lee, Jeong-Cheol; Rhee, Sang-Hoon

    2016-02-01

    In the synthesis of hydroxyapatite powders by spray pyrolysis, control of the particle size was investigated by varying the initial concentration of the precursor solution and the pyrolysis temperature. Calcium phosphate solutions (Ca/P ratio of 1.67) with a range of concentrations from 0.1 to 2.0 mol/L were prepared by dissolving calcium nitrate tetrahydrate and diammonium hydrogen phosphate in deionized water and subsequently adding nitric acid. Hydroxyapatite powders were then synthesized by spray pyrolysis at 900°C and at 1500°C, using these calcium phosphate precursor solutions, under the fixed carrier gas flow rate of 10 L/min. The particle size decreased as the precursor concentration decreased and the spray pyrolysis temperature increased. Sinterability tests conducted at 1100°C for 1 h showed that the smaller and denser the particles were, the higher the relative densities were of sintered hydroxyapatite disks formed from these particles. The practical implication of these results is that highly sinterable small and dense hydroxyapatite particles can be synthesized by means of spray pyrolysis using a low-concentration precursor solution and a high pyrolysis temperature under a fixed carrier gas flow rate. © 2015 Wiley Periodicals, Inc.

  16. Percutaneous nephrostomy for symptomatic hypermobile kidney: a single centre experience.

    PubMed

    Starownik, Radosław; Golabek, Tomasz; Bar, Krzysztof; Muc, Kamil; Płaza, Paweł; Chlosta, Piotr

    2014-12-01

    Symptomatic hypermobile kidney is treated with nephropexy, a surgical procedure through which the floating kidney is fixed to the retroperitoneum. Although both open and endoscopic procedures have a high success rate, they can be associated with risk of complications, relatively long hospital stay and high cost. We describe our percutaneous technique for fixing a hypermobile kidney and evaluate the efficacy of the percutaneous nephrostomy insertion in management of symptomatic nephroptosis. Between January 2005 and December 2011, 11 patients diagnosed with a symptomatic right nephroptosis of at least 1 year duration were treated with a single point percutaneous nephrostomy technique. All data were retrieved from patients' medical records and then retrospectively analysed. Nephropexy through a single point percutaneous nephrostomy technique was successfully accomplished in 11 women. The mean operative time was 20 min. The intraoperative estimated blood loss was minimal in all cases. No major or minor intraoperative complications were noted. The average postoperative hospital stay was 2 days. Women returned to their usual activities 14 days following the surgery. Nine women had complete resolution of their pain, and 2 patients continued to complain of discomfort in their lumbar area. One patient was re-operated upon with satisfactory subjective and objective outcomes achieved. One patient refused re-operation. Percutaneous nephropexy is simple, inexpensive and effective for treatment of symptomatic hypermobile kidney. It remains a valuable alternative to open, laparoscopic, and robotic methods for fixing a floating kidney.

  17. Operation Uphold Democracy: Observations on Joint Assault Forces Operated from a CV.

    DTIC Science & Technology

    1996-07-01

    shipboard environment. This was particularly a problem for post-maintenance check flights ( PMCFs ). JSOTF pilots were appar- ently accustomed to making...able to accommodate late requests for PMCFs . Again, procedures designed for cyclic, fixed-wing operations should not be arbitrarily imposed. FOD

  18. 45 CFR 99.21 - Authority of presiding officer.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... HEARINGS FOR THE CHILD CARE AND DEVELOPMENT FUND Hearing Procedures § 99.21 Authority of presiding officer... therein; (7) Examine witnesses; (8) Receive, rule on, exclude or limit evidence or discovery; (9) Fix the... to compel by subpoena the production of witnesses, papers, or other evidence. ...

  19. 45 CFR 99.21 - Authority of presiding officer.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... HEARINGS FOR THE CHILD CARE AND DEVELOPMENT FUND Hearing Procedures § 99.21 Authority of presiding officer... therein; (7) Examine witnesses; (8) Receive, rule on, exclude or limit evidence or discovery; (9) Fix the... to compel by subpoena the production of witnesses, papers, or other evidence. ...

  20. 45 CFR 99.21 - Authority of presiding officer.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... HEARINGS FOR THE CHILD CARE AND DEVELOPMENT FUND Hearing Procedures § 99.21 Authority of presiding officer... therein; (7) Examine witnesses; (8) Receive, rule on, exclude or limit evidence or discovery; (9) Fix the... to compel by subpoena the production of witnesses, papers, or other evidence. ...

  1. 45 CFR 99.21 - Authority of presiding officer.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... HEARINGS FOR THE CHILD CARE AND DEVELOPMENT FUND Hearing Procedures § 99.21 Authority of presiding officer... therein; (7) Examine witnesses; (8) Receive, rule on, exclude or limit evidence or discovery; (9) Fix the... to compel by subpoena the production of witnesses, papers, or other evidence. ...

  2. Using a Self-Control Training Procedure To Increase Appropriate Behavior.

    ERIC Educational Resources Information Center

    Dixon, Mark R.; Hayes, Linda J.; Binder, Lisa M.; Manthey, Sharon; Sigman, Connie; Zdanowski, Darlene M.

    1998-01-01

    A study evaluated teaching a technique for self-control to three adults with developmental disabilities. Concurrent fixed-duration/progressive-duration reinforcement schedules were introduced in which both smaller and larger reinforcers were available immediately. When progressively increasing delays were introduced for the larger reinforcer,…

  3. Oscillations of a String with Concentrated Masses

    ERIC Educational Resources Information Center

    Gomez, B. J.; Repetto, C. E.; Stia, C. R.; Welti, R.

    2007-01-01

    In this work, the oscillations of a homogeneous string fixed at both ends, and loaded with a finite number of masses, are studied. Through a simple device, the cases with one and two concentrated masses are analysed in detail. The normal modes are observed and the corresponding frequencies are recorded. The experimental results and the solutions…

  4. Application of Differential Colorimetry To Evaluate Anthocyanin-Flavonol-Flavanol Ternary Copigmentation Interactions in Model Solutions.

    PubMed

    Gordillo, Belén; Rodríguez-Pulido, Francisco J; González-Miret, M Lourdes; Quijada-Morín, Natalia; Rivas-Gonzalo, Julián C; García-Estévez, Ignacio; Heredia, Francisco J; Escribano-Bailón, M Teresa

    2015-09-09

    The combined effect of anthocyanin-flavanol-flavonol ternary interactions on the colorimetric and chemical stability of malvidin-3-glucoside has been studied. Model solutions with fixed malvidin-3-glucoside/(+)-catechin ratio (MC) and variable quercetin-3-β-d-glucoside concentration (MC+Q) and solutions with fixed malvidin-3-glucoside/quercetin-3-β-d-glucoside ratio (MQ) and variable (+)-catechin concentration (MQ+C) were tested at levels closer to those existing in wines. Color variations during storage were evaluated by differential colorimetry. Changes in the anthocyanin concentration were monitored by HPLC-DAD. CIELAB color-difference formulas were demonstrated to be of practical interest to assess the stronger and more stable interaction of quercetin-3-β-d-glucoside with MC binary mixture than (+)-catechin with MQ mixture. The results imply that MC+Q ternary solutions kept their intensity and bluish tonalities for a longer time in comparison to MQ+C solutions. The stability of malvidin-3-glucoside improves when the concentration of quercetin-3-β-d-glucoside increases in MC+Q mixtures, whereas the addition of (+)-catechin in MQ+C mixtures resulted in an opposite effect.

  5. Removal and recovery of acetic acid and two furans during sugar purification of simulated phenols-free biomass hydrolysates.

    PubMed

    Lee, Sang Cheol

    2017-12-01

    A cost-effective five-step sugar purification process involving simultaneous removal and recovery of fermentation inhibitors from biomass hydrolysates was first proposed here. Only the three separation steps (PB, PC and PD) in the process were investigated here. Furfural was selectively removed up to 98.4% from a simulated five-component hydrolysate in a cross-current three-stage extraction system with n-hexane. Most of acetic acid in a simulated four-component hydrolysate was selectively removed by emulsion liquid membrane, and it could be concentrated in the stripping solution up to 4.5 times its initial concentration in the feed solution. 5-Hydroxymethylfurfural was selectively removed from a simulated three-component hydrolysate in batch and continuous fixed-bed column adsorption systems with L-493 adsorbent. Also, 5-hydroxymethylfurfural could be concentrated to about 9 times its feed concentration in the continuous adsorption system through a fixed-bed column desorption experiment with aqueous ethanol solution. These results have shown that the proposed purification process was valid. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Analysis of free zone electrophoresis of fixed erythrocytes performed in microgravity

    NASA Technical Reports Server (NTRS)

    Snyder, Robert S.; Rhodes, Percy H.; Herren, Blair J.; Miller, Teresa Y.; Seaman, Geoffrey V. F.

    1985-01-01

    A free fluid zone electrophoresis experiment was performed in the microgravity environment of Space Shuttle flight STS-3 (March 1983). The experiment was designed to confirm observations made on the Apollo-Soyuz mission of 1975 and to test the effect of high red blood cell (RBC) concentration on free fluid electrophoresis. Photographic documentation of cell zone progression in one-hour separations of mixtures of formaldehyde-fixed human and rabbit erythrocytes, which were subjected to a field of approximately 13 V/cm in low ionic strength buffer, was analyzed. One of two columns contained 2 x 10 to the 8th RBC/ml; (low concentration), and the other contained 1 x 10 to the 9th RBC/ml (high concentration). The observed and calculated leading edge displacements of the RBC in the two columns were in agreement, indicating the absence of unexpected effects of the reduced gravity environment. Post-flight analyses of the contents of the columns was not possible, and additional microgravity experiments are needed to evaluate the role of particle-particle interactions in concentrated suspensions undergoing electrophoresis.

  7. [Adsorption of the TiO2 @ yeast composite microspheres for adsorbing Fluorescent Whitening Agent-VBL in fixed bed].

    PubMed

    Wu, Fei; Zhang, Kai-Qiang; Bai, Bo; Wang, Hong-Lun; Suo, You-Rui

    2015-02-01

    In this work, the adsorption potential of TiO2@ yeast composite microspheres to remove Fluorescent Whitening Agent-VBL (FWA-VBL) from aqueous solution was investigated using fixed-bed adsorption column. The effects of pH(2.0-8.0), bed height (1-3 cm), inlet concentration (20-80 mg x L(-1)) and feed flow rate (5-11 mL x min(-1)) on the breakthrough characteristics of the adsorption system were determined. The results showed that the highest bed capacity of 223.80 mg x g(-1) was obtained under the condition of pH 2.0, 80 mg x L(-1) inlet dye concentration, 1.0 cm bed height and 5 mL x min(-1) flow rate. The adsorption data were fitted to three well-established fixed-bed adsorption models, namely, BDST model, Thomas model and Yoon-Nelson model. The results fitted well to the three models with coefficients of correlation R2 > 0.980 in different conditions. The TiO2 @ yeast composite microspheres have desired regeneration ability and could be reused for four times.

  8. Microbiological Safety of Processed Meat Products Formulated with Low Nitrite Concentration: A Mini Review.

    PubMed

    Lee, Soomin; Lee, Heeyoung; Kim, Sejeong; Lee, Jeeyeon; Ha, Jimyeong; Choi, Yukyung; Oh, Hyemin; Choi, Kyoung-Hee; Yoon, Yohan

    2018-03-13

    Nitrite plays a major role in inhibiting the growth of foodborne pathogens, including Clostridium botulinum that causes botulism, a life-threatening disease. Nitrite serves as a color-fixing agent in processed meat products. However, N-nitroso compounds can be produced from nitrite. They are considered as carcinogens. Thus, consumers desire processed meat products that contain lower concentrations (below conventional concentrations of products) of nitrite or no nitrite at all, although the portion of nitrite intake by processed meat consumption in total nitrite intake is very low. However, lower nitrite levels might expose consumers to risk of botulism poisoning due to C. botulinum or illness caused by other foodborne pathogens. Hence, lower nitrite concentrations in combination with other factors such as low pH, high NaCl level, and others have been recommended to decrease the risk of food poisoning. In addition, natural compounds that can inhibit bacterial growth and function as color-fixing agents have been developed to replace nitrite in processed meat products. However, their antibotulinal effects have not been fully clarified. Therefore, to have processed meat products with lower nitrite concentrations, low pH, high NaCl concentration, and others should also be applied together. Before using natural compounds as replacement of nitrite, their antibotulinal activities should be examined.

  9. Fixed-interval performance and self-control in infants.

    PubMed Central

    Darcheville, J C; Rivière, V; Wearden, J H

    1993-01-01

    Twenty-six infants, 3 to 23 months old, were trained on fixed-interval schedules ranging from 10 s to 80 s. The operant response was touching an illuminated location on a touch-sensitive screen, and 20 s of cartoon presentation was the reinforcer. The subjects were also trained in a six-phase self-control procedure in which the critical phases involved choice between 20 s of cartoon available after a 0.5-s delay (impulsive choice) and 40 s of cartoon delayed for 40 s (self-controlled choice). All the youngest children (3 to 5 months) showed long postreinforcement pauses on the fixed-interval schedule, with most intervals involving the emission of a single, reinforced, response, and all made self-controlled choices. Older subjects (9 to 23 months) either produced the same pattern as the younger ones on the fixed-interval schedule (classified as pause-sensitive subjects) or produced short pauses and higher steady response rates (classified as pause-insensitive subjects). All pause-sensitive subjects made self-controlled choices in the self-control condition, and all pause-insensitive subjects made impulsive ones. PMID:8409821

  10. Preclinical safety and efficacy of a new recombinant FIX drug product for treatment of hemophilia B.

    PubMed

    Dietrich, Barbara; Schiviz, Alexandra; Hoellriegl, Werner; Horling, Frank; Benamara, Karima; Rottensteiner, Hanspeter; Turecek, Peter L; Schwarz, Hans Peter; Scheiflinger, Friedrich; Muchitsch, Eva-Maria

    2013-11-01

    Baxter has developed a new recombinant factor IX (rFIX) drug product (BAX326) for treating patients with hemophilia B, or congenital FIX deficiency. An extensive preclinical program evaluated the pharmacokinetics, efficacy, and safety of BAX326 in different species. The efficacy of BAX326 was tested in three mouse models of primary pharmacodynamics: tail-tip bleeding, carotid occlusion, and thrombelastography. The pharmacokinetics was evaluated after a single intravenous bolus injection in mice, rats, and macaques. Toxicity was assessed in rats and macaques, safety pharmacology in rabbits and macaques, and immunogenicity in mice. BAX326 was shown to be efficacious in all three primary pharmacodynamic studies (P ≤ 0.0076). Hemostatic efficacy was dose related and similar for the three lots tested. Pharmacokinetic results showed that rFIX activity and rFIX antigen concentrations declined in a bi-phasic manner, similar to a previously licensed rFIX product. BAX326 was well tolerated in rabbits and macaques at all dose levels; no thrombogenic events and no adverse clinical, respiratory, or cardiovascular effects occurred. BAX326 was also shown to have a similar immunogenicity profile to the comparator rFIX product in mice. These results demonstrate that BAX326 has a favorable preclinical safety and efficacy profile, predictive of a comparable effect to that of the previously licensed rFIX in humans.

  11. Fixed Nadir Focus Concentrated Solar Power Applying Reflective Array Tracking Method

    NASA Astrophysics Data System (ADS)

    Setiawan, B.; DAMayanti, A. M.; Murdani, A.; Habibi, I. I. A.; Wakidah, R. N.

    2018-04-01

    The Sun is one of the most potential renewable energy develoPMent to be utilized, one of its utilization is for solar thermal concentrators, CSP (Concentrated Solar Power). In CSP energy conversion, the concentrator is as moving the object by tracking the sunlight to reach the focus point. This method need quite energy consumption, because the unit of the concentrators has considerable weight, and use large CSP, means the existence of the usage unit will appear to be wider and heavier. The addition of weight and width of the unit will increase the torque to drive the concentrator and hold the wind gusts. One method to reduce energy consumption is direct the sunlight by the reflective array to nadir through CSP with Reflective Fresnel Lens concentrator. The focus will be below the nadir direction, and the position of concentrator will be fixed position even the angle of the sun’s elevation changes from morning to afternoon. So, the energy concentrated maximally, because it has been protected from wind gusts. And then, the possibility of dAMage and changes in focus construction will not occur. The research study and simulation of the reflective array (mechanical method) will show the reflective angle movement. The distance between reflectors and their angle are controlled by mechatronics. From the simulation using fresnel 1m2, and efficiency of solar energy is 60.88%. In restriction, the intensity of sunlight at the tropical circles 1KW/peak, from 6 AM until 6 PM.

  12. Students' perceptions of materials and techniques used at European dental schools in the education of fixed prosthodontics.

    PubMed

    Brand, Henk S; Kamell, Hassib; Kharbanda, Aron K; Dozic, Alma

    2013-09-01

    The aim of this study was to explore the materials and procedures used by students in dental schools across Europe for teaching fixed prosthodontics. An online questionnaire, containing twenty-eight dichotomous, multiple-choice, and Likert scale rating questions, was sent to students in forty dental schools. After excluding dental schools in which less than 10 percent of the students responded, 775 questionnaires from ten schools remained for statistical analysis. Among these respondents, acrylic resin teeth were said to be the most commonly used material during preclinical practice (46-96 percent), and use of extracted teeth varied from 8 to 65 percent. At nine of the ten institutions, metal-ceramic was reported to be most commonly used for fixed dental prostheses. There was large variation in the type of finish line for a metal-ceramic fixed dental prosthesis: students at five institutions reported using a shoulder finish line, three a chamfer finish line, and two a shoulder-bevel finish line. A similar variation was observed with regard to the final cementation of metal-ceramic fixed dental prostheses: students at four institutions reporting most frequently using glass ionomer cement, with three using zinc phosphate cement and three using carboxylate cement. The responding European dental students varied considerably in their opinions about whether they were preclinically properly trained for the first preparation on a patient and in their overall rating of their education in fixed prosthodontics. Responding students in the United Kingdom, Sweden, and Nijmegen, The Netherlands, rated their fixed prosthodontics training overall the highest. Overall, this study found a wide variation amongst dental schools with regard to their education in fixed prosthodontics and their rating of this teaching.

  13. Competitive adsorption between benzene and ethylene dichloride on activated carbon: The importance of concentration

    NASA Astrophysics Data System (ADS)

    Miao, T.; Tang, H. M.; Cheng, Z. X.

    2018-03-01

    In this work we studied breakthroughs of binary mixtures of benzene and ethylene dichloride on fixed activated carbons bed. The results show a series of assault concentrations on activated carbon bed influences the nature of the adsorption competition mechanism. Assault concentration were used to determine how competition of compound distribution. The results are discussed in terms of competing energetic and the underlying molecular mechanisms. The ratio of assault concentrations is main reason for determining selectivity.

  14. Racial composition, unemployment, and crime: dealing with inconsistencies in panel designs.

    PubMed

    Worrall, John L

    2008-09-01

    Racial composition and unemployment have appeared as either theoretically-relevant controls or variables of substantive interest in numerous studies of crime. While there is no clear consensus in the literature as to their statistical significance, the lack of consensus has been most apparent in panel analyses with unit fixed effects. One explanation for this is that racial composition and unemployment are fairly invariant, or slow-moving, which leads to collinearity with unit dummies. A number of pertinent studies are reviewed to illustrate how two slow-moving variables, percent black and percent unemployed, have behaved inconsistently. A fixed effects vector decomposition procedure [Plumper, V., Troeger, V. E., 2007. Efficient estimation of time-invariant and rarely changing variables in finite sample panel analyses with unit fixed effects. Political Analysis, 15, 124-139.] is used to illustrate how these variables' coefficients appear positive and significant when the slow-moving process is accounted for.

  15. Rationalisation and Validation of an Acrylamide-Free Procedure in Three-Dimensional Histological Imaging

    PubMed Central

    Lai, Hei Ming; Liu, Alan King Lun; Ng, Wai-Lung; DeFelice, John; Lee, Wing Sang; Li, Heng; Li, Wen; Ng, Ho Man; Chang, Raymond Chuen-Chung; Lin, Bin; Wu, Wutian; Gentleman, Steve M.

    2016-01-01

    Three-dimensional visualization of intact tissues is now being achieved by turning tissues transparent. CLARITY is a unique tissue clearing technique, which features the use of detergents to remove lipids from fixed tissues to achieve optical transparency. To preserve tissue integrity, an acrylamide-based hydrogel has been proposed to embed the tissue. In this study, we examined the rationale behind the use of acrylamide in CLARITY, and presented evidence to suggest that the omission of acrylamide-hydrogel embedding in CLARITY does not alter the preservation of tissue morphology and molecular information in fixed tissues. We therefore propose a novel and simplified workflow for formaldehyde-fixed tissue clearing, which will facilitate the laboratory implementation of this technique. Furthermore, we have investigated the basic tissue clearing process in detail and have highlighted some areas for targeted improvement of technologies essential for the emerging subject of three-dimensional histology. PMID:27359336

  16. Effects of video-assisted training on employment-related social skills of adults with severe mental retardation.

    PubMed Central

    Morgan, R L; Salzberg, C L

    1992-01-01

    Two studies investigated effects of video-assisted training on employment-related social skills of adults with severe mental retardation. In video-assisted training, participants discriminated a model's behavior on videotape and received feedback from the trainer for responses to questions about video scenes. In the first study, 3 adults in an employment program participated in video-assisted training to request their supervisor's assistance when encountering work problems. Results indicated that participants discriminated the target behavior on video but effects did not generalize to the work setting for 2 participants until they rehearsed the behavior. In the second study, 2 participants were taught to fix and report four work problems using video-assisted procedures. Results indicated that after participants rehearsed how to fix and report one or two work problems, they began to fix and report the remaining problems with video-assisted training alone. PMID:1378826

  17. A Machine-Checked Proof of A State-Space Construction Algorithm

    NASA Technical Reports Server (NTRS)

    Catano, Nestor; Siminiceanu, Radu I.

    2010-01-01

    This paper presents the correctness proof of Saturation, an algorithm for generating state spaces of concurrent systems, implemented in the SMART tool. Unlike the Breadth First Search exploration algorithm, which is easy to understand and formalise, Saturation is a complex algorithm, employing a mutually-recursive pair of procedures that compute a series of non-trivial, nested local fixed points, corresponding to a chaotic fixed point strategy. A pencil-and-paper proof of Saturation exists, but a machine checked proof had never been attempted. The key element of the proof is the characterisation theorem of saturated nodes in decision diagrams, stating that a saturated node represents a set of states encoding a local fixed-point with respect to firing all events affecting only the node s level and levels below. For our purpose, we have employed the Prototype Verification System (PVS) for formalising the Saturation algorithm, its data structures, and for conducting the proofs.

  18. Comparison of Fixed Point Realisations between Inmetro and PTB

    NASA Astrophysics Data System (ADS)

    Santiago, J. F. N.; Petkovic, S. G.; Teixeira, R. N.; Noatsch, U.; Thiele-Krivoj, B.

    2003-09-01

    An interlaboratory comparison in the temperature range between -190 °C and 420 °C was organised between the National Institute of Quality, Normalisation and Industrial Quality (Inmetro), Brazil, and the Physikalisch Technische Bundesanstalt (PTB), Germany. This comparison followed the same protocol as the EUROMET project 552 comparison and was carried out in the years 2001-2002. A standard platinum resistance thermometer (SPRT) of 25 Ω was calibrated at the temperature fixed points of Ar, Hg, the triple point of water (TWP), Ga, In, Sn and Zn, with at least three realisations of each fixed point at both institutes. The uncertainty evaluation is given by Inmetro and some differences in the calibration procedures or in the measuring instruments used are described. The agreement between the results of laboratories was not in all cases within the combined uncertainties. Results of other comparisons are presented, which give additional information on the equivalence of the realised temperature scales.

  19. An investigation on the effects of air on electron energy in atmospheric pressure helium plasma jets

    NASA Astrophysics Data System (ADS)

    Liu, Yadi; Tan, Zhenyu; Chen, Xinxian; Li, Xiaotong; Zhang, Huimin; Pan, Jie; Wang, Xiaolong

    2018-03-01

    In this work, the effects of air on electron energy in the atmospheric pressure helium plasma jet produced by a needle-plane discharge system have been investigated by means of the numerical simulation based on a two-dimensional fluid model, and the air concentration dependences of the reactive species densities have also been calculated. In addition, the synergistic effects of the applied voltage and air concentration on electron energy have been explored. The present work gives the following significant results. For a fixed applied voltage, the averaged electron energy is basically a constant at air concentrations below about 0.5%, but it evidently decreases above the concentration of 0.5%. Furthermore, the averaged densities of four main reactive species O, O(1D), O2(1Δg), and N2(A3Σu+) increase with the increasing air concentration, but the increase becomes slow at air concentrations above 0.5%. The air concentration dependences of the averaged electron energy under different voltage amplitudes are similar, and for a given air concentration, the averaged electron energy increases with the increase in the voltage amplitude. For the four reactive species, the effects of the air concentration on their averaged densities are similar for a given voltage amplitude. In addition, the averaged densities of the four reactive species increase with increasing voltage amplitude for a fixed air concentration. The present work suggests that a combination of high voltage amplitude and the characteristic air concentration, 0.5% in the present discharge system, allows an expected electron energy and also generates abundant reactive species.

  20. Temporal integration in nasal lateralization of homologous propionates.

    PubMed

    Wise, Paul M; Toczydlowski, Sean E; Zhao, Kai; Wysocki, Charles J

    2009-08-01

    For nasal irritation from volatile chemicals, a version of Haber's rule (k = C(n)T) can model the trade-off between concentration (C) and duration of exposure (T) to achieve a fixed sensory impact, e.g. threshold-level irritation or a fixed suprathreshold intensity. The term k is a constant. The exponent, n, represents how well the system integrates over time. An exponent of 1 indicates complete temporal integration: an x-fold increase in stimulus duration exactly compensates for cutting the concentration 1/x. An exponent greater than 1 indicates incomplete temporal integration: more than an x-fold increase in duration is needed. In a previous study of homologous alcohols, n varied systematically with number of methylene units: integration became more complete as the length of the carbon chain increased. To explore the generality of this finding, we tested homologous esters that differ in the number of methylene units: n-ethyl propionate, n-propyl propionate, and n-butyl propionate. Nasal lateralization was used to measure irritation thresholds. Human subjects received a fixed concentration of a single compound within each experimental session. Stimulus duration was varied to find the briefest stimulus that caused lateralizable irritation. Concentration and compound varied across sessions. Consistent with results with n-alcohols, integration became more complete as the number of methylene units increased. Lipid solubility varies with chain length; hence, solubility in the nasal mucosa may play a role in the dynamics of irritation. Further, preliminary analyses suggest that, for data pooled across both chemical series, n varies systematically with molecular parameters related to solubility and diffusion.

  1. Preparative isolation of aquatic humic substances

    USGS Publications Warehouse

    Thurman, E.M.; Malcolm, R.L.

    1981-01-01

    A useful procedure has been developed which utilizes adsorption chromatography followed by size-exclusion chromatography, hydrogen saturation by ion exchange, and lypholization to obtain low-ash aqueous humic substances. The preparative concentration of aquatic humic substances is done by multiple reconcentration procedures even though initial concentrations of aqueous humus may be less than 25 ??g/L. The procedure yields concentration factors of 25 000 times for both humic and fulvic acid in water.

  2. Energetics of muscle contraction: the whole is less than the sum of its parts

    NASA Technical Reports Server (NTRS)

    Kushmerick, M. J.; Conley, K. E.

    2002-01-01

    Understanding muscle energetics is a problem in optimizing supply of ATP to the demands of ATPases. The complexity of reactions and their fluxes to achieve this balance is greatly reduced by recognizing constraints imposed by the integration of common metabolites at fixed stoichiometry among modular units. ATPase is driven externally. Oxidative phosphorylation and glycogenolysis are the suppliers. We focus on their regulation which involves different controls, but reduces to two principles that enable facile experimental analysis of the supply and demand fluxes. The ratio of concentration of phosphocreatine (PCr) to ATP, not their individual values, sets the range of achievable concentrations of ADP in resting and active muscle (at fixed pH) in different cell types. This principle defines the fraction of available flux of oxidative phosphorylation utilized (at fixed enzyme activities). Then the kinetics of PCr recovery defines the kinetics of oxygen supply and substrate utilization. The second principle is the constancy of PCr and H(+) (lactate) production by glycogenolysis due to the coupling of ATPase and glycolysis. This principle enables glycogenolytic flux to be measured from intracellular proton loads. Further simplification occurs because the magnitude of the interacting fluxes and metabolite concentrations are specified within narrow limits when both the resting and active fluxes are quantified. Thus there is a small set of rules for assessing and understanding the thermodynamics and kinetics of muscle energetics.

  3. KommonBase - A precise direct bonding system for labial fixed appliances.

    PubMed

    Miyashita, Wataru; Komori, Akira; Takemoto, Kyoto

    2017-09-01

    "KommonBase" is a system designed to customize the bracket base by means of an extended resin base covering the tooth. This system enables precise bracket placement and accurate fit on teeth. Moreover, KommonBase can be easily fabricated in a laboratory and bonded on each tooth using simple clinical procedures. Straight-wire treatment without wire bending was achieved in the clinical cases presented in this article using the KommonBase system for a labial fixed appliance. The application of KommonBase to the vestibular side enables efficient orthodontic treatment using simple mechanics. Copyright © 2017 CEO. Published by Elsevier Masson SAS. All rights reserved.

  4. [Comments on the use of the "life-table method" in orthopedics].

    PubMed

    Hassenpflug, J; Hahne, H J; Hedderich, J

    1992-01-01

    In the description of long term results, e.g. of joint replacements, survivorship analysis is used increasingly in orthopaedic surgery. The survivorship analysis is more useful to describe the frequency of failure rather than global statements in percentage. The relative probability of failure for fixed intervals is drawn from the number of controlled patients and the frequency of failure. The complementary probabilities of success are linked in their temporal sequence thus representing the probability of survival at a fixed endpoint. Necessary condition for the use of this procedure is the exact definition of moment and manner of failure. It is described how to establish survivorship tables.

  5. New layer-based imaging and rapid prototyping techniques for computer-aided design and manufacture of custom dental restoration.

    PubMed

    Lee, M-Y; Chang, C-C; Ku, Y C

    2008-01-01

    Fixed dental restoration by conventional methods greatly relies on the skill and experience of the dental technician. The quality and accuracy of the final product depends mostly on the technician's subjective judgment. In addition, the traditional manual operation involves many complex procedures, and is a time-consuming and labour-intensive job. Most importantly, no quantitative design and manufacturing information is preserved for future retrieval. In this paper, a new device for scanning the dental profile and reconstructing 3D digital information of a dental model based on a layer-based imaging technique, called abrasive computer tomography (ACT) was designed in-house and proposed for the design of custom dental restoration. The fixed partial dental restoration was then produced by rapid prototyping (RP) and computer numerical control (CNC) machining methods based on the ACT scanned digital information. A force feedback sculptor (FreeForm system, Sensible Technologies, Inc., Cambridge MA, USA), which comprises 3D Touch technology, was applied to modify the morphology and design of the fixed dental restoration. In addition, a comparison of conventional manual operation and digital manufacture using both RP and CNC machining technologies for fixed dental restoration production is presented. Finally, a digital custom fixed restoration manufacturing protocol integrating proposed layer-based dental profile scanning, computer-aided design, 3D force feedback feature modification and advanced fixed restoration manufacturing techniques is illustrated. The proposed method provides solid evidence that computer-aided design and manufacturing technologies may become a new avenue for custom-made fixed restoration design, analysis, and production in the 21st century.

  6. 77 FR 70382 - Airworthiness Directives; Eurocopter France Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-26

    ... the fuel tank draining system. This proposed AD is prompted by a closed fuel tank drain that, in the... fuel tank compartments' draining system. FAA's Determination These helicopters have been approved by... buoyancy fixed parts, the ASBs describe procedures to modify the fuel tank draining system by removing...

  7. 22 CFR 401.23 - Hearings.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Hearings. 401.23 Section 401.23 Foreign Relations INTERNATIONAL JOINT COMMISSION, UNITED STATES AND CANADA RULES OF PROCEDURE Applications § 401.23 Hearings. (a) The time and place of the hearing or hearings of an application shall be fixed by the...

  8. 47 CFR 80.71 - Operating controls for stations on land.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Operating controls for stations on land. 80.71... SERVICES STATIONS IN THE MARITIME SERVICES Operating Requirements and Procedures Station Requirements-Land Stations § 80.71 Operating controls for stations on land. Each coast station, Alaska-public fixed station...

  9. A Design Selection Procedure.

    ERIC Educational Resources Information Center

    Kroeker, Leonard P.

    The problem of blocking on a status variable was investigated. The one-way fixed-effects analysis of variance, analysis of covariance, and generalized randomized block designs each treat the blocking problem in a different way. In order to compare these designs, it is necessary to restrict attention to experimental situations in which observations…

  10. 7 CFR 283.17 - Post-hearing procedure.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., but not later than the time fixed for filing proposed findings of fact, conclusions of law, order and... text). (b) Proposed findings of fact, conclusions of law, order, and briefs. The parties may file proposed findings of fact, conclusions of law and orders based solely upon the record and on officially...

  11. 7 CFR 283.17 - Post-hearing procedure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., but not later than the time fixed for filing proposed findings of fact, conclusions of law, order and... text). (b) Proposed findings of fact, conclusions of law, order, and briefs. The parties may file proposed findings of fact, conclusions of law and orders based solely upon the record and on officially...

  12. 46 CFR 110.10-1 - Incorporation by reference.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...-31; 111.105-39; 111.105-40; 113.05-7; and (2) Rules for Building and Classing Mobile Offshore... Installations of Ships and Mobile and Fixed Offshore Units—Part 1: Procedures for Calculating Short-Circuit... Park, NC 27709: (1) RP 12.6, Wiring Practices for Hazardous (Classified) Locations Instrumentation Part...

  13. 46 CFR 4.21-1 - Computation of time.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... COAST GUARD, DEPARTMENT OF HOMELAND SECURITY PROCEDURES APPLICABLE TO THE PUBLIC MARINE CASUALTIES AND... computed by excluding the first day and including the last unless the last day is Sunday or a legal holiday... legal holiday: Provided, however, That where the time fixed by the regulations in this subchapter or an...

  14. 40 CFR 63.695 - Inspection and monitoring requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... monitoring procedures required to perform the following: (1) To inspect tank fixed roofs and floating roofs... and floating roof inspection requirements. (1) Owners and operators that use a tank equipped with an internal floating roof in accordance with the provisions of § 63.685(e) of this subpart shall meet the...

  15. Pragmatic Rationality in Education.

    ERIC Educational Resources Information Center

    Haynes, Felicity

    In the last few decades there has been a move in philosophy of education toward a concept of pragmatic rationality. This paper examines whether the move away from systematicity, fixed guiding principles or logical systems, makes this notion of pragmatic rationality so broad that it can encompass any procedure of selection which involves rules, no…

  16. Teaching Classical Statistical Mechanics: A Simulation Approach.

    ERIC Educational Resources Information Center

    Sauer, G.

    1981-01-01

    Describes a one-dimensional model for an ideal gas to study development of disordered motion in Newtonian mechanics. A Monte Carlo procedure for simulation of the statistical ensemble of an ideal gas with fixed total energy is developed. Compares both approaches for a pseudoexperimental foundation of statistical mechanics. (Author/JN)

  17. Task-switching cost and repetition priming: two overlooked confounds in the first-set procedure of the Sternberg paradigm and how they affect memory set-size effects.

    PubMed

    Jou, Jerwen

    2014-10-01

    Subjects performed Sternberg-type memory recognition tasks (Sternberg paradigm) in four experiments. Category-instance names were used as learning and testing materials. Sternberg's original experiments demonstrated a linear relation between reaction time (RT) and memory-set size (MSS). A few later studies found no relation, and other studies found a nonlinear relation (logarithmic) between the two variables. These deviations were used as evidence undermining Sternberg's serial scan theory. This study identified two confounding variables in the fixed-set procedure of the paradigm (where multiple probes are presented at test for a learned memory set) that could generate a MSS RT function that was either flat or logarithmic rather than linearly increasing. These two confounding variables were task-switching cost and repetition priming. The former factor worked against smaller memory sets and in favour of larger sets whereas the latter factor worked in the opposite way. Results demonstrated that a null or a logarithmic RT-to-MSS relation could be the artefact of the combined effects of these two variables. The Sternberg paradigm has been used widely in memory research, and a thorough understanding of the subtle methodological pitfalls is crucial. It is suggested that a varied-set procedure (where only one probe is presented at test for a learned memory set) is a more contamination-free procedure for measuring the MSS effects, and that if a fixed-set procedure is used, it is worthwhile examining the RT function of the very first trials across the MSSs, which are presumably relatively free of contamination by the subsequent trials.

  18. Matrix solid-phase dispersion on column clean-up/pre-concentration as a novel approach for fast isolation of abuse drugs from human hair.

    PubMed

    Míguez-Framil, Martha; Moreda-Piñeiro, Antonio; Bermejo-Barrera, Pilar; Alvarez-Freire, Iván; Tabernero, María Jesús; Bermejo, Ana María

    2010-10-08

    A simple and fast sample pre-treatment method based on matrix solid-phase dispersion (MSPD) for isolating cocaine, benzoylecgonine (BZE), codeine, morphine and 6-monoacethylmorphine (6-MAM) from human hair has been developed. The MSPD approach consisted of using alumina (1.80 g) as a dispersing agent and 0.6M hydrochloric acid (4 mL) as an extracting solvent. For a fixed hair sample mass of 0.050 g, the alumina mass to sample mass ratio obtained was 36. A previously conditioned Oasis HLB cartridge (2 mL methanol, plus 2 mL ultrapure water, plus 1 mL of 0.2M/0.2M sodium hydroxide/boric acid buffer solution at pH 9.2) was attached to the end of the MSPD syringe for on column clean-up of the hydrochloric acid extract and for transferring the target compounds to a suitable solvent for gas chromatography (GC) analysis. Therefore, the adsorbed analytes were directly eluted from the Oasis HLB cartridges with 2 mL of 2% acetic acid in methanol before concentration by N(2) stream evaporation and dry extract derivatization with N-methyl-tert-butylsilyltrifluoroacetamide (BSTFA) and chlorotrimethylsilane (TMCS). The optimization/evaluation of all the factors affecting the MSPD and on column clean-up procedures has led to a fast sample treatment, and analytes extraction and pre-concentration can be finished in approximately 30 min. The developed method has been applied to eight hair samples from poli-drug abusers and measured analyte concentrations have been found to be statistically similar (95% confidence interval) to those obtained after a conventional enzymatic hydrolysis method (Pronase E). Copyright © 2010. Published by Elsevier B.V.

  19. Gingival-colored Porcelain: A Clinical Report of an Esthetic-prosthetic Paradigm

    PubMed Central

    Sonune, Shital Jalandar; Kumar, Shiv; Jadhav, Manish Shivaji; Martande, Santosh

    2017-01-01

    Traditionally, periodontics has been instrumental in treating hard- and soft-tissue defect. Surgical and regenerative periodontal procedures can reconstruct the three-dimensional architecture of the hard- and soft-tissue defect. However, at times, these invasive procedures leave the patients with an esthetic problem. In such situations, the defects can be treated by the prosthetic approach. A predictable esthetically pleasing and functional outcome without any surgical procedure is being a choice of treatment for many. This article discusses about the treatment for the defect of excessive hard and soft tissue, using porcelain fused to a metal restoration with gingival-colored porcelain for both tooth-supported and implant-supported fixed prosthesis. PMID:29308371

  20. Fixed bed column study for water defluoridation using neem oil-phenolic resin treated plant bio-sorbent.

    PubMed

    Manna, Suvendu; Saha, Prosenjit; Roy, Debasis; Adhikari, Basudam; Das, Papita

    2018-04-15

    Fluoride has both detrimental and beneficial effects on living beings depending on the concentration and consumption periods. The study presented in this article investigated the feasibility of using neem oil phenolic resin treated lignocellulosic bio-sorbents for fluoride removal from water through fixed bed column study. Results indicated that treated bio-sorbents could remove fluoride both from synthetic and groundwater with variable bed depth, flow rate, fluoride concentration and column diameter. Data obtained from this study indicated that columns with the thickest bed, lowest flow rate, and fluoride concentration showed best column performance. Bio-sorbents used in this study are regenerable and reusable for more than five cycles. The initial materials cost needed to remove one gram of fluoride also found to be lower than the available alternatives. This makes the process more promising candidate to be used for fluoride removal. In addition, the process is also technically advantageous over the available alternatives. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Association of circulating concentrations of estradiol during the preovulatory period and expression of steroidogenic enzymes in beef cows

    USDA-ARS?s Scientific Manuscript database

    Cows with greater circulating concentrations of estradiol during the preovulatory period (HighE2) have increased pregnancy success following a fixed-time AI protocol. Furthermore, these animals have an enhanced ability to produce estradiol as indicated by increased expression of CYP19A1 and LHR wit...

  2. Construction of a Cr3C2-C Peritectic Point Cell for Thermocouple Calibration

    NASA Astrophysics Data System (ADS)

    Ogura, Hideki; Deuze, Thierry; Morice, Ronan; Ridoux, Pascal; Filtz, Jean-Remy

    The melting points of Cr3C2-C peritectic (1826°C) and Cr7C3-Cr3C2 eutectic (1742°C) alloys as materials for high-temperature fixed point cells are investigated for the use of thermocouple calibration. Pretests are performed to establish a suitable procedure for constructing contact thermometry cells based on such chromium-carbon mixtures. Two cells are constructed following two different possible procedures. The above two melting points are successfully observed for one of these cells using tungsten-rhenium alloy thermocouples.

  3. Perfect discretization of path integrals

    NASA Astrophysics Data System (ADS)

    Steinhaus, Sebastian

    2012-05-01

    In order to obtain a well-defined path integral one often employs discretizations. In the case of General Relativity these generically break diffeomorphism symmetry, which has severe consequences since these symmetries determine the dynamics of the corresponding system. In this article we consider the path integral of reparametrization invariant systems as a toy example and present an improvement procedure for the discretized propagator. Fixed points and convergence of the procedure are discussed. Furthermore we show that a reparametrization invariant path integral implies discretization independence and acts as a projector onto physical states.

  4. User's manual for the Shuttle Electric Power System analysis computer program (SEPS), volume 2 of program documentation

    NASA Technical Reports Server (NTRS)

    Bains, R. W.; Herwig, H. A.; Luedeman, J. K.; Torina, E. M.

    1974-01-01

    The Shuttle Electric Power System Analysis SEPS computer program which performs detailed load analysis including predicting energy demands and consumables requirements of the shuttle electric power system along with parameteric and special case studies on the shuttle electric power system is described. The functional flow diagram of the SEPS program is presented along with data base requirements and formats, procedure and activity definitions, and mission timeline input formats. Distribution circuit input and fixed data requirements are included. Run procedures and deck setups are described.

  5. Transient chloride binding as a contributory factor to corneal stromal swelling in the ox.

    PubMed Central

    Hodson, S; Kaila, D; Hammond, S; Rebello, G; al-Omari, Y

    1992-01-01

    1. Investigations were made of the cation exchange capacity of fresh isolated ox corneal stroma (Q, units: mequiv fixed stromal charge/kg stromal fluid) at pH 7.4 over a variety of stomal hydrations (H, units: kg stromal fluid/kg dry tissue) both above and below the physiological hydration of 3.2, whilst the stromas were immersed in a variety of sodium chloride solutions (range 5-1000 mM). 2. At any particular salt concentration, the product QH (dry tissue exchange capacity, units: mequiv/kg dry tissue) appeared constant, over all the hydrations investigated. 3. Dry tissue exchange capacity (QH) varied, however, when the bathing salt concentration was altered. It varied between 55 mequiv/kg dry tissue (e.g. Q = 17 mequiv at H = 3.2) in 5 mM-NaCl to 240 mequiv/kg dry tissue (e.g. Q = 75 mequiv/l at H = 3.2) in 1000 mM-NaCl. 4. The variation of stromal exchange capacity in NaCl solutions of different concentrations was similar when detected by three independent procedures: stromal gel pressure measurements, intrastromal sodium ion distributions, and intrastromal electrical potentials. 5. Intrastromal chloride ion distributions were anomalous. Total chloride (measured by radio-isotopes) was consistently higher than that predicted by Donnan theory. 6. The data were consistent with Elliott's hypothesis that a fraction of intrastromal chloride ions bind to the corneal stromal matrix and in so doing contribute to the fixed negative charge of the stroma. 7. Our observations may be explained by a model of the cation exchange capacity of ox cornea which has two types of components. On is (at constant pH) invariant, and has a dry tissue exchange capacity of about 50 mequiv/kg dry tissue, and is probably generated by the sulphonic and carboxylic acid groups of the glycosaminoglycans. The other is explained by supposing it to consist of a chloride binding ligand which exhibits first order binding, is half occupied at ambient chloride concentrations of 300 mM, and has a total capacity of 240 mequiv/kg dry tissue. 8. Partial stromal extraction with 4 M-guanidine HCl indicated that the chloride binding ligand is not associated with the collagen molecules in the corneal stromal fibrils. 9. It is suggested that such a stromal chloride ion binding ligand would help to stabilize the hydration and transparency of the living cornea when it is exposed to environments of varying tonicity (such as in river or sea bathing). PMID:1432722

  6. Water-quality assessment of the eastern Iowa basins- nitrogen, phosphorus, suspended sediment, and organic carbon in surface water, 1996-98

    USGS Publications Warehouse

    Becher, Kent D.; Kalkhoff, Stephen J.; Schnoebelen, Douglas J.; Barnes, Kimberlee K.; Miller, Von E.

    2001-01-01

    Synoptic samples collected during low and high base flow had nitrogen, phosphorus, and organic-carbon concentrations that varied spatially and seasonally. Comparisons of water-quality data from six basic-fixed sampling sites and 19 other synoptic sites suggest that the water-quality data from basic-fixed sampling sites were representative of the entire study unit during periods of low and high base flow when most streamflow originates from ground water.

  7. Assessing the effectiveness of 30% sodium chloride aqueous solution for the preservation of fixed anatomical specimens: a 5-year follow-up study.

    PubMed

    de Oliveira, Fabrício Singaretti

    2014-07-01

    Anatomical specimens used in human or veterinary anatomy laboratories are usually prepared with formaldehyde (a cancerous and teratogenic substance), glycerin (an expensive and viscous fluid), or ethanol (which is flammable). This research aimed to verify the viability of an aqueous 30% sodium chloride solution for preservation of anatomical specimens previously fixed with formaldehyde. Anatomical specimens of ruminant, carnivorous, equine, swine and birds were used. All were previously fixed with an aqueous 20% formaldehyde solution and held for 7 days in a 10% aqueous solution of the same active ingredient. During the first phase of the experiment, small specimens of animal tissue previously fixed in formaldehyde were distributed in vials with different concentrations of formaldehyde, with or without 30% sodium chloride solution, a group containing only 30% sodium chloride, and a control group containing only water. During this phase, no contamination was observed in any specimen containing 30% sodium chloride solution, whether alone or in combination with different concentrations of formaldehyde. In the second phase of the experiment, the 30% sodium chloride solution, found to be optimal in the first phase of the experiment, was tested for its long-term preservation properties. For a period of 5 years, the preserved specimens were evaluated three times a week for visual contamination, odors, and changes in color and texture. There was no visual contamination or decay found in any specimen. Furthermore, no strange odors, or changes in color or softness were noted. The 30% sodium chloride solution was determined to be effective in the preservation of anatomic specimens previously fixed in formaldehyde. © 2014 Anatomical Society.

  8. Assessing the effectiveness of 30% sodium chloride aqueous solution for the preservation of fixed anatomical specimens: a 5-year follow-up study

    PubMed Central

    de Oliveira, Fabrício Singaretti

    2014-01-01

    Anatomical specimens used in human or veterinary anatomy laboratories are usually prepared with formaldehyde (a cancerous and teratogenic substance), glycerin (an expensive and viscous fluid), or ethanol (which is flammable). This research aimed to verify the viability of an aqueous 30% sodium chloride solution for preservation of anatomical specimens previously fixed with formaldehyde. Anatomical specimens of ruminant, carnivorous, equine, swine and birds were used. All were previously fixed with an aqueous 20% formaldehyde solution and held for 7 days in a 10% aqueous solution of the same active ingredient. During the first phase of the experiment, small specimens of animal tissue previously fixed in formaldehyde were distributed in vials with different concentrations of formaldehyde, with or without 30% sodium chloride solution, a group containing only 30% sodium chloride, and a control group containing only water. During this phase, no contamination was observed in any specimen containing 30% sodium chloride solution, whether alone or in combination with different concentrations of formaldehyde. In the second phase of the experiment, the 30% sodium chloride solution, found to be optimal in the first phase of the experiment, was tested for its long-term preservation properties. For a period of 5 years, the preserved specimens were evaluated three times a week for visual contamination, odors, and changes in color and texture. There was no visual contamination or decay found in any specimen. Furthermore, no strange odors, or changes in color or softness were noted. The 30% sodium chloride solution was determined to be effective in the preservation of anatomic specimens previously fixed in formaldehyde. PMID:24762210

  9. Numerical model simulations of nitrate concentrations in groundwater using various nitrogen input scenarios, mid-Snake region, south-central Idaho

    USGS Publications Warehouse

    Skinner, Kenneth D.; Rupert, Michael G.

    2012-01-01

    As part of the U.S. Geological Survey’s National Water Quality Assessment (NAWQA) program nitrate transport in groundwater was modeled in the mid-Snake River region in south-central Idaho to project future concentrations of nitrate. Model simulation results indicated that nitrate concentrations would continue to increase over time, eventually exceeding the U.S. Environmental Protection Agency maximum contaminant level for drinking water of 10 milligrams per liter in some areas. A subregional groundwater model simulated the change of nitrate concentrations in groundwater over time in response to three nitrogen input scenarios: (1) nitrogen input fixed at 2008 levels; (2) nitrogen input increased from 2008 to 2028 using the same rate of increase as the average rate of increase during the previous 10 years (1998 through 2008); after 2028, nitrogen input is fixed at 2028 levels; and (3) nitrogen input related to agriculture completely halted, with only nitrogen input from precipitation remaining. Scenarios 1 and 2 project that nitrate concentrations in groundwater continue to increase from 10 to 50 years beyond the year nitrogen input is fixed, depending on the location in the model area. Projected nitrate concentrations in groundwater increase by as much as 2–4 milligrams per liter in many areas, with nitrate concentrations in some areas reaching 10 milligrams per liter. Scenario 3, although unrealistic, estimates how long (20–50 years) it would take nitrate in groundwater to return to background concentrations—the “flushing time” of the system. The amount of nitrate concentration increase cannot be explained solely by differences in nitrogen input; in fact, some areas with the highest amount of nitrogen input have the lowest increase in nitrate concentration. The geometry of the aquifer and the pattern of regional groundwater flow through the aquifer greatly influence nitrate concentrations. The aquifer thins toward discharge areas along the Snake River which forces upward convergence of good-quality regional groundwater that mixes with the nitrate-laden groundwater in the uppermost parts of the aquifer, which results in lowered nitrate concentrations. A new method of inputting nitrogen to the subregional groundwater model was used that prorates nitrogen input by the probability of detecting nitrate concentrations greater than 2 mg/L. The probability map is based on correlations with physical factors, and prorates an existing nitrogen input dataset providing an estimate of nitrogen flux to the water table that accounts for new factors such as soil properties. The effectiveness of this updated nitrogen input method was evaluated using the software UCODE_2005.

  10. Air quality at night markets in Taiwan.

    PubMed

    Zhao, Ping; Lin, Chi-Chi

    2010-03-01

    In Taiwan, there are more than 300 night markets and they have attracted more and more visitors in recent years. Air quality in night markets has become a public concern. To characterize the current air quality in night markets, four major night markets in Kaohsiung were selected for this study. The results of this study showed that the mean carbon dioxide (CO2) concentrations at fixed and moving sites in night markets ranged from 326 to 427 parts per million (ppm) during non-open hours and from 433 to 916 ppm during open hours. The average carbon monoxide (CO) concentrations at fixed and moving sites in night markets ranged from 0.2 to 2.8 ppm during non-open hours and from 2.1 to 14.1 ppm during open hours. The average 1-hr levels of particulate matter with aerodynamic diameters less than 10 microm (PM10) and less than 2.5 microm (PM2.5) at fixed and moving sites in night markets were high, ranging from 186 to 451 microg/m3 and from 175 to 418 microg/m3, respectively. The levels of PM2.5 accounted for 80-97% of their respective PM10 concentrations. The average formaldehyde (HCHO) concentrations at fixed and moving sites in night markets ranged from 0 to 0.05 ppm during non-open hours and from 0.02 to 0.27 ppm during open hours. The average concentration of individual polycyclic aromatic hydrocarbons (PAHs) was found in the range of 0.09 x 10(4) to 1.8 x 10(4) ng/m3. The total identified PAHs (TIPs) ranged from 7.8 x 10(1) to 20 x 10(1) ng/m3 during non-open hours and from 1.5 x 10(4) to 4.0 x 10(4) ng/m3 during open hours. Of the total analyzed PAHs, the low-molecular-weight PAHs (two to three rings) were the dominant species, corresponding to an average of 97% during non-open hours and 88% during open hours, whereas high-molecular-weight PAHs (four to six rings) represented 3 and 12% of the total detected PAHs in the gas phase during non-open and open hours, respectively.

  11. Ecogenomic sensor reveals controls on N2-fixing microorganisms in the North Pacific Ocean.

    PubMed

    Robidart, Julie C; Church, Matthew J; Ryan, John P; Ascani, François; Wilson, Samuel T; Bombar, Deniz; Marin, Roman; Richards, Kelvin J; Karl, David M; Scholin, Christopher A; Zehr, Jonathan P

    2014-06-01

    Nitrogen-fixing microorganisms (diazotrophs) are keystone species that reduce atmospheric dinitrogen (N2) gas to fixed nitrogen (N), thereby accounting for much of N-based new production annually in the oligotrophic North Pacific. However, current approaches to study N2 fixation provide relatively limited spatiotemporal sampling resolution; hence, little is known about the ecological controls on these microorganisms or the scales over which they change. In the present study, we used a drifting robotic gene sensor to obtain high-resolution data on the distributions and abundances of N2-fixing populations over small spatiotemporal scales. The resulting measurements demonstrate that concentrations of N2 fixers can be highly variable, changing in abundance by nearly three orders of magnitude in less than 2 days and 30 km. Concurrent shipboard measurements and long-term time-series sampling uncovered a striking and previously unrecognized correlation between phosphate, which is undergoing long-term change in the region, and N2-fixing cyanobacterial abundances. These results underscore the value of high-resolution sampling and its applications for modeling the effects of global change.

  12. N2-fixing red alder indirectly accelerates ecosystem nitrogen cycling

    USGS Publications Warehouse

    Perakis, Steven S.; Matkins, Joselin J.; Hibbs, David E.

    2012-01-01

    Symbiotic N2-fixing tree species can accelerate ecosystem N dynamics through decomposition via direct pathways by producing readily decomposed leaf litter and increasing N supply to decomposers, as well as via indirect pathways by increasing tissue and detrital N in non-fixing vegetation. To evaluate the relative importance of these pathways, we compared three-year decomposition and N dynamics of N2-fixing red alder leaf litter (2.34 %N) to both low-N (0.68 %N) and high-N (1.21 %N) litter of non-fixing Douglas-fir, and decomposed each litter source in four forests dominated by either red alder or Douglas-fir. We also used experimental N fertilization of decomposition plots to assess elevated N availability as a potential mechanism of N2-fixer effects on litter mass loss and N dynamics. Direct effects of N2-fixing red alder on decomposition occurred primarily as faster N release from red alder than Douglas-fir litter, but direct increases in N supply to decomposers via fertilization did not stimulate decomposition of any litter. Fixed N indirectly influenced detrital dynamics by increasing Douglas-fir tissue and litter N concentrations, which accelerated litter N release without accelerating mass loss. By increasing soil N, tissue N, and the rate of N release from litter of non-fixers, we conclude that N2-fixing vegetation can indirectly foster plant-soil feedbacks that contribute to the persistence of elevated N availability in terrestrial ecosystems.

  13. Effects of sorption competition on caesium diffusion through compacted argillaceous rock

    NASA Astrophysics Data System (ADS)

    Jakob, Andreas; Pfingsten, Wilfried; Van Loon, Luc

    2009-05-01

    We carried out a small-scale laboratory diffusion experiment on a disk-like sample of Opalinus clay from the Mont Terri underground laboratory (Switzerland) using 134Cs as tracer. A through-diffusion phase was followed by an out-diffusion phase where the tracer taken up by the sample was released again. Since the tracer concentration at both boundaries was monitored, careful mass-balance considerations were feasible. A first analysis of the experimental data was done in the frame of a single-species model accounting only for transport and non-linear sorption of caesium. The model could match the data of the through-diffusion phase, however only, when strongly reducing the sorption data based on batch sorption experiments. Yet, such a procedure was in strong contradiction with sorption measurements performed on dispersed and compacted systems. In addition, predictions concerning tracer out-diffusion and mass-balance considerations clearly revealed the shortcomings of this type of model. In a second attempt we applied a multi-species transport model where now the whole water chemistry and a sorption model for caesium were considered. First, the value for the diffusion coefficient was fixed to the best-fit value of the single-species model. But again, the sorption site densities had to be reduced strongly albeit the reduction factor was smaller. Only when fixing the sorption site densities to those values of the sorption model and letting the effective diffusion coefficient D e free for the adjustment, could through-diffusion data be reasonably well fitted and out-diffusion as well as mass-balances be predicted in a satisfying manner. The main results are: (1) The best-fit could be achieved with a value for D e of 1.8 × 10 -10 m 2 s -1 which is rather high but corroborated by results of a molecular modelling study. (2) If caesium arrives in the Opalinus clay sample potassium and sodium (calcium etc.) ions are released and caesium ions are sorbed. The released cations diffuse to lower concentration regions according to their individual concentration gradients. Since locally the cation concentration for potassium, (sodium and calcium) is increased, sorption of these cations is also locally enhanced, affecting in return the sorption behaviour of migrating caesium. Consequently, the sorption process of caesium in such diffusion experiments cannot be addressed by a non-linear isotherm formalism any longer. (3) A reasonable analysis of such single tracer diffusion experiments therefore requires the combined description of transport (diffusion) and sorption of many cations and the whole complex water chemistry of the system. Thus, single-species models can only be applied with care in the considered concentration ranges.

  14. Productive Recognition of Factor IX by Factor XIa Exosites Requires Disulfide Linkage between Heavy and Light Chains of Factor XIa*

    PubMed Central

    Marcinkiewicz, Mariola M.; Sinha, Dipali; Walsh, Peter N.

    2012-01-01

    In the intrinsic pathway of blood coagulation factor XIa (FXIa) activates factor IX (FIX) by cleaving the zymogen at Arg145-Ala146 and Arg180-Val181 bonds releasing an 11-kDa activation peptide. FXIa and its isolated light chain (FXIa-LC) cleave S-2366 at comparable rates, but FXIa-LC is a very poor activator of FIX, possibly because FIX undergoes allosteric modification on binding to an exosite on the heavy chain of FXIa (FXIa-HC) required for optimal cleavage rates of the two scissile bonds of FIX. However preincubation of FIX with a saturating concentration of isolated FXIa-HC did not result in any potentiation in the rate of FIX cleavage by FXIa-LC. Furthermore, if FIX binding via the heavy chain exosite of FXIa determines the affinity of the enzyme-substrate interaction, then the isolated FXIa-HC should inhibit the rate of FIX activation by depleting the substrate. However, whereas FXIa/S557A inhibited FIX activation of by FXIa, FXIa-HC did not. Therefore, we examined FIX binding to FXIa/S557A, FXIa-HC, FXIa-LC, FXIa/C362S/C482S, and FXIa/S557A/C362S/C482S. The heavy and light chains are disulfide-linked in FXIa/S557A but not in FXIa/C362S/C482S and FXIa/S557A/C362S/C482S. In an ELISA assay only FXI/S557A ligated FIX with high affinity. Partial reduction of FXIa/S557A to produce heavy and light chains resulted in decreased FIX binding, and this function was regained upon reformation of the disulfide linkage between the heavy and the light chains. We therefore conclude that substrate recognition by the FXIa exosite(s) requires disulfide-linked heavy and light chains. PMID:22207756

  15. Lichen physiological traits and growth forms affect communities of associated invertebrates.

    PubMed

    Bokhorst, Stef; Asplund, Johan; Kardol, Paul; Wardle, David A

    2015-09-01

    While there has been much interest in the relationships between traits of primary producers and composition of associated invertebrate consumer communities, our knowledge is largely based on studies from vascular plants, while other types of functionally important producers, such as lichens, have rarely been considered. To address how physiological traits of lichens drive community composition of invertebrates, we collected thalli from 27 lichen species from southern Norway and quantified the communities of associated springtails, mites, and nematodes. For each lichen species, we measured key physiological thallus traits and determined whether invertebrate communities were correlated with these traits. We also explored whether invertebrate communities differed among lichen groups, categorized according to nitrogen-fixing ability, growth form, and substratum. Lichen traits explained up to 39% of the variation in abundances of major invertebrate groups. For many invertebrate groups, abundance was positively correlated with lichen N and P concentrations, N:P ratio, and the percentage of water content on saturation (WC), but had few relationships with concentrations of carbon-based secondary compounds. Diversity and taxonomic richness of invertebrate groups were sometimes also correlated with lichen N and N:P ratios. Nitrogen-fixing lichens showed higher abundance and diversity of some invertebrate groups than did non-N-fixing lichens. However, this emerged in part because most N-fixing lichens have a foliose growth form that benefits invertebrates, through, improving the microclimate, independently of N concentration. Furthermore, invertebrate communities associated with terricolous lichens were determined more by their close proximity to the soil invertebrate pool than by lichen traits. Overall, our results reveal that differences between lichen species have a large impact on the invertebrate communities that live among the thalli. Different invertebrate groups show contrasting responses to traits that are indicative of thallus quality (nutrient concentrations), and thallus growth form is often an important determinant of the invertebrate community. Given the large diversity of lichen traits and growth forms that occur in many ecosystems, lichen-invertebrate communities may be an important contributor to overall community diversity in boreal forests.

  16. Simplified procedure for the immediate loading of a complete fixed prosthesis supported by four implants in the maxillary jaw: a 2-year prospective study.

    PubMed

    Piano, Sergio; Romeo, Eugenio; Sbricoli, Luca; Pisoni, Gianluca; Cea, Niccoló; Lops, Diego

    2016-12-01

    The aim of this study was to verify the reliability of a system for the fixed retention of complete maxillary prostheses supported by four implants with a follow-up of 2 years. Patients were treated between September 2009 and December 2010 with four Straumann Bone Level SLActive implants supporting a complete prosthesis (CPs). The two distal implants were positioned mesially to the maxillary sinus and with a mesio-distal inclination ≤ 30° in order to reduce the distal prosthesis cantilever. An immediate loading surgical protocol was used. The CPs were planned to be fixed to multibase abutments to test their retention for a fixed rehabilitation. Clinical and radiographic parameters as probing pocket depth (PPD), bleeding score (mBI), plaque index (PI), and marginal bone loss (MBL) were assessed at a 1- and 2-year follow-up visits. Moreover, any biological and prosthodontic maintenance events were recorded. Clinical and radiographic parameters changes were analyzed. Twenty-one patients treated with a total of 84 implants completed the 2-year examination period. Four patients were lost to follow up. No technical complication was recorded. Also, no implant, reconstruction, or abutment failures were observed. Therefore, an implant and prosthetic survival rate of 100% were achieved after 2 years. The mean periodontal parameter scores after 2 years of function were 2.6 mm for PPD (SD 0.8 mm), 0.3 for mBI (SD 0.5 mm), and 1.2 for PI (SD 0.4 mm) indexes, respectively. In addition, the mean MBL score measured at the 2-year follow-up visit was -0.34 mm (SD of -0.45 mm). Furthermore, no peri-implant soft tissue inflammation or peri-implant infection was observed. It has been shown that immediate loading of four implants positioned anteriorly to the maxillary sinus could be a reliable treatment procedure to support fixed complete restorations. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Wind-Tunnel Evaluation of the Effect of Blade Nonstructural Mass Distribution on Helicopter Fixed-System Loads

    NASA Technical Reports Server (NTRS)

    Wilbur, Matthew L.; Yeager, William T., Jr.; Singleton, Jeffrey D.; Mirick, Paul H.; Wilkie, W. Keats

    1998-01-01

    This report provides data obtained during a wind-tunnel test conducted to investigate parametrically the effect of blade nonstructural mass on helicopter fixed-system vibratory loads. The data were obtained with aeroelastically scaled model rotor blades that allowed for the addition of concentrated nonstructural masses at multiple locations along the blade radius. Testing was conducted for advance ratios ranging from 0.10 to 0.35 for 10 blade-mass configurations. Three thrust levels were obtained at representative full-scale shaft angles for each blade-mass configuration. This report provides the fixed-system forces and moments measured during testing. The comprehensive database obtained is well-suited for use in correlation and development of advanced rotorcraft analyses.

  18. Volcano fixes nitrogen into plant-available forms

    USGS Publications Warehouse

    Huebert, B.; Vitousek, P.; Sutton, J.; Elias, T.; Heath, J.; Coeppicus, S.; Howell, S.; Blomquist, B.

    1999-01-01

    Hawaiian montane ecosystems developing on recent tephra deposits contain more fixed nitrogen than conventional sources can explain. Heath and Huebert (1999) demonstrated that cloud water interception is the mechanism by which this extra nitrogen is deposited, but could not identify its source. We show here that atmospheric dinitrogen is fixed at the surface of active lava flows, producing concentrations of NO which are higher than those found in most urban rush hour air pollution. Over a period of hours this NO is blown away from the island and oxidized to nitrate. Interruptions in the trade wind flow can return this nitrate to the island to be deposited in cloud water. Thus, fixation on active lava flows is able to provide nitrogen to developing ecosystems on flows emplaced earlier.

  19. Traveltime and dispersion in the Potomac River, Cumberland, Maryland, to Washington, D.C.

    USGS Publications Warehouse

    Taylor, K.R.; James, R.W.; Helinsky, B.M.

    1984-01-01

    Data from two traveltime and dispersion studies, using rhodamine dye, are used to develop a generalized procedure for predicting traveltime and downstream concentrations resulting from spillage of water-soluble substances at any point along the Potomac River from Cumberland, Maryland, to Washington, D.C. The procedure will allow the approximate solution to almost any spillage problem concerning traveltime and concentration during periods of relatively steady flow between 50- and 95-percent flow duration. A new procedure for calculating unit peak concentration is derived. The new procedure, based on the similarity in shape of a time-concentration curve and a scalene triangle, allows unit peak concentration to be expressed in terms of the length of the dye cloud. This approach facilitates the linking of peak-concentration attenuation curves for long reaches of rivers which are divided into subreaches for study. An example problem is solved for a hypothetical spill of 20,000 pounds of contaminant at Magnolia, West Virginia. The predicted traveltime of the leading edge, peak concentration, and trailing edge to Point of Rocks, Maryland (110 miles downstream), are 295 , 375, and 540 hours, respectively, for a flow duration of 80 percent. The predicted maximum concentration is 340 micrograms/L. (USGS)

  20. Development of a lectin binding assay to differentiate between recombinant and endogenous proteins in pharmacokinetic studies of protein-biopharmaceuticals.

    PubMed

    Weber, Alfred; Minibeck, Eva; Scheiflinger, Friedrich; Turecek, Peter L

    2015-04-10

    Human glycoproteins, expressed in hamster cell lines, show similar glycosylation patterns to naturally occurring human molecules except for a minute difference in the linkage of terminal sialic acid: both cell types lack α2,6-galactosyl-sialyltransferase, abundantly expressed in human hepatocytes and responsible for the α2,6-sialylation of circulating glycoproteins. This minute difference, which is currently not known to have any physiological relevance, was the basis for the selective measurement of recombinant glycoproteins in the presence of their endogenous counterparts. The assay is based on using the lectin Sambucus nigra agglutinin (SNA), selectively binding to α2,6-sialylated N-glycans. Using von Willebrand factor (VWF), factor IX (FIX), and factor VIIa (FVIIa), it was demonstrated that (i) the plasma-derived proteins, but not the corresponding recombinant proteins, specifically bind to SNA and (ii) this binding can be used to deplete the plasma-derived proteins. The feasibility of this approach was confirmed in spike-recovery studies for all three recombinant coagulation proteins in human plasma and for recombinant VWF (rVWF) in macaque plasma. Analysis of plasma samples from macaques after administration of recombinant and a plasma-derived VWF demonstrated the suitability and robustness of this approach. Data showed that rVWF could be selectively measured without changing the ELISAs and furthermore revealed the limitations of baseline adjustment using a single measurement of the predose concentration only. The SNA gel-based depletion procedure can easily be integrated in existing procedures as a specific sample pre-treatment step. While ELISA-based methods were used to measure the recombinant coagulation proteins in the supernatants obtained by depletion, this procedure is applicable for all biochemical analyses. Copyright © 2015 Elsevier B.V. All rights reserved.

Top