Pilot Comparison of Radiance Temperature Scale Realization Between NIMT and NMIJ
NASA Astrophysics Data System (ADS)
Keawprasert, T.; Yamada, Y.; Ishii, J.
2015-03-01
A pilot comparison of radiance temperature scale realizations between the National Institute of Metrology Thailand (NIMT) and the National Metrology Institute of Japan (NMIJ) was conducted. At the two national metrology institutes (NMIs), a 900 nm radiation thermometer, used as the transfer artifact, was calibrated by a means of a multiple fixed-point method using the fixed-point blackbody of Zn, Al, Ag, and Cu points, and by means of relative spectral responsivity measurements according to the International Temperature Scale of 1990 (ITS-90) definition. The Sakuma-Hattori equation is used for interpolating the radiance temperature scale between the four fixed points and also for extrapolating the ITS-90 temperature scale to 2000 C. This paper compares the calibration results in terms of fixed-point measurements, relative spectral responsivity, and finally the radiance temperature scale. Good agreement for the fixed-point measurements was found in case a correction for the change of the internal temperature of the artifact was applied using the temperature coefficient measured at the NMIJ. For the realized radiance temperature range from 400 C to 1100 C, the resulting scale differences between the two NMIs are well within the combined scale comparison uncertainty of 0.12 C (). The resulting spectral responsivity measured at the NIMT has a comparable curve to that measured at the NMIJ especially in the out-of-band region, yielding a ITS-90 scale difference within 1.0 C from the Cu point to 2000 C, whereas the realization comparison uncertainty of NIMT and NMIJ combined is 1.2 C () at 2000 C.
Svensson, Elin M; Yngman, Gunnar; Denti, Paolo; McIlleron, Helen; Kjellsson, Maria C; Karlsson, Mats O
2018-05-01
Fixed-dose combination formulations where several drugs are included in one tablet are important for the implementation of many long-term multidrug therapies. The selection of optimal dose ratios and tablet content of a fixed-dose combination and the design of individualized dosing regimens is a complex task, requiring multiple simultaneous considerations. In this work, a methodology for the rational design of a fixed-dose combination was developed and applied to the case of a three-drug pediatric anti-tuberculosis formulation individualized on body weight. The optimization methodology synthesizes information about the intended use population, the pharmacokinetic properties of the drugs, therapeutic targets, and practical constraints. A utility function is included to penalize deviations from the targets; a sequential estimation procedure was developed for stable estimation of break-points for individualized dosing. The suggested optimized pediatric anti-tuberculosis fixed-dose combination was compared with the recently launched World Health Organization-endorsed formulation. The optimized fixed-dose combination included 15, 36, and 16% higher amounts of rifampicin, isoniazid, and pyrazinamide, respectively. The optimized fixed-dose combination is expected to result in overall less deviation from the therapeutic targets based on adult exposure and substantially fewer children with underexposure (below half the target). The development of this design tool can aid the implementation of evidence-based formulations, integrating available knowledge and practical considerations, to optimize drug exposures and thereby treatment outcomes.
NASA Technical Reports Server (NTRS)
Lomax, Harvard
1957-01-01
Several variational problems involving optimum wing and body combinations having minimum wave drag for different kinds of geometrical restraints are analyzed. Particular attention is paid to the effect on the wave drag of shortening the fuselage and, for slender axially symmetric bodies, the effect of fixing the fuselage diameter at several points or even of fixing whole portions of its shape.
Asymptotic safety of quantum gravity beyond Ricci scalars
NASA Astrophysics Data System (ADS)
Falls, Kevin; King, Callum R.; Litim, Daniel F.; Nikolakopoulos, Kostas; Rahmede, Christoph
2018-04-01
We investigate the asymptotic safety conjecture for quantum gravity including curvature invariants beyond Ricci scalars. Our strategy is put to work for families of gravitational actions which depend on functions of the Ricci scalar, the Ricci tensor, and products thereof. Combining functional renormalization with high order polynomial approximations and full numerical integration we derive the renormalization group flow for all couplings and analyse their fixed points, scaling exponents, and the fixed point effective action as a function of the background Ricci curvature. The theory is characterized by three relevant couplings. Higher-dimensional couplings show near-Gaussian scaling with increasing canonical mass dimension. We find that Ricci tensor invariants stabilize the UV fixed point and lead to a rapid convergence of polynomial approximations. We apply our results to models for cosmology and establish that the gravitational fixed point admits inflationary solutions. We also compare findings with those from f (R ) -type theories in the same approximation and pin-point the key new effects due to Ricci tensor interactions. Implications for the asymptotic safety conjecture of gravity are indicated.
Rigorous high-precision enclosures of fixed points and their invariant manifolds
NASA Astrophysics Data System (ADS)
Wittig, Alexander N.
The well established concept of Taylor Models is introduced, which offer highly accurate C0 enclosures of functional dependencies, combining high-order polynomial approximation of functions and rigorous estimates of the truncation error, performed using verified arithmetic. The focus of this work is on the application of Taylor Models in algorithms for strongly non-linear dynamical systems. A method is proposed to extend the existing implementation of Taylor Models in COSY INFINITY from double precision coefficients to arbitrary precision coefficients. Great care is taken to maintain the highest efficiency possible by adaptively adjusting the precision of higher order coefficients in the polynomial expansion. High precision operations are based on clever combinations of elementary floating point operations yielding exact values for round-off errors. An experimental high precision interval data type is developed and implemented. Algorithms for the verified computation of intrinsic functions based on the High Precision Interval datatype are developed and described in detail. The application of these operations in the implementation of High Precision Taylor Models is discussed. An application of Taylor Model methods to the verification of fixed points is presented by verifying the existence of a period 15 fixed point in a near standard Henon map. Verification is performed using different verified methods such as double precision Taylor Models, High Precision intervals and High Precision Taylor Models. Results and performance of each method are compared. An automated rigorous fixed point finder is implemented, allowing the fully automated search for all fixed points of a function within a given domain. It returns a list of verified enclosures of each fixed point, optionally verifying uniqueness within these enclosures. An application of the fixed point finder to the rigorous analysis of beam transfer maps in accelerator physics is presented. Previous work done by Johannes Grote is extended to compute very accurate polynomial approximations to invariant manifolds of discrete maps of arbitrary dimension around hyperbolic fixed points. The algorithm presented allows for automatic removal of resonances occurring during construction. A method for the rigorous enclosure of invariant manifolds of continuous systems is introduced. Using methods developed for discrete maps, polynomial approximations of invariant manifolds of hyperbolic fixed points of ODEs are obtained. These approximations are outfit with a sharp error bound which is verified to rigorously contain the manifolds. While we focus on the three dimensional case, verification in higher dimensions is possible using similar techniques. Integrating the resulting enclosures using the verified COSY VI integrator, the initial manifold enclosures are expanded to yield sharp enclosures of large parts of the stable and unstable manifolds. To demonstrate the effectiveness of this method, we construct enclosures of the invariant manifolds of the Lorenz system and show pictures of the resulting manifold enclosures. To the best of our knowledge, these enclosures are the largest verified enclosures of manifolds in the Lorenz system in existence.
Comparison of Fixed Point Realisations between Inmetro and PTB
NASA Astrophysics Data System (ADS)
Santiago, J. F. N.; Petkovic, S. G.; Teixeira, R. N.; Noatsch, U.; Thiele-Krivoj, B.
2003-09-01
An interlaboratory comparison in the temperature range between -190 °C and 420 °C was organised between the National Institute of Quality, Normalisation and Industrial Quality (Inmetro), Brazil, and the Physikalisch Technische Bundesanstalt (PTB), Germany. This comparison followed the same protocol as the EUROMET project 552 comparison and was carried out in the years 2001-2002. A standard platinum resistance thermometer (SPRT) of 25 Ω was calibrated at the temperature fixed points of Ar, Hg, the triple point of water (TWP), Ga, In, Sn and Zn, with at least three realisations of each fixed point at both institutes. The uncertainty evaluation is given by Inmetro and some differences in the calibration procedures or in the measuring instruments used are described. The agreement between the results of laboratories was not in all cases within the combined uncertainties. Results of other comparisons are presented, which give additional information on the equivalence of the realised temperature scales.
Milner, Allison; Aitken, Zoe; Kavanagh, Anne; LaMontagne, Anthony D; Pega, Frank; Petrie, Dennis
2017-06-23
Previous studies suggest that poor psychosocial job quality is a risk factor for mental health problems, but they use conventional regression analytic methods that cannot rule out reverse causation, unmeasured time-invariant confounding and reporting bias. This study combines two quasi-experimental approaches to improve causal inference by better accounting for these biases: (i) linear fixed effects regression analysis and (ii) linear instrumental variable analysis. We extract 13 annual waves of national cohort data including 13 260 working-age (18-64 years) employees. The exposure variable is self-reported level of psychosocial job quality. The instruments used are two common workplace entitlements. The outcome variable is the Mental Health Inventory (MHI-5). We adjust for measured time-varying confounders. In the fixed effects regression analysis adjusted for time-varying confounders, a 1-point increase in psychosocial job quality is associated with a 1.28-point improvement in mental health on the MHI-5 scale (95% CI: 1.17, 1.40; P < 0.001). When the fixed effects was combined with the instrumental variable analysis, a 1-point increase psychosocial job quality is related to 1.62-point improvement on the MHI-5 scale (95% CI: -0.24, 3.48; P = 0.088). Our quasi-experimental results provide evidence to confirm job stressors as risk factors for mental ill health using methods that improve causal inference. © The Author 2017. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
NASA Astrophysics Data System (ADS)
Pearce, Jonathan V.; Gisby, John A.; Steur, Peter P. M.
2016-08-01
A knowledge of the effect of impurities at the level of parts per million on the freezing temperature of very pure metals is essential for realisation of ITS-90 fixed points. New information has become available for use with the thermodynamic modelling software MTDATA, permitting calculation of liquidus slopes, in the low concentration limit, of a wider range of binary alloy systems than was previously possible. In total, calculated values for 536 binary systems are given. In addition, new experimental determinations of phase diagrams, in the low impurity concentration limit, have recently appeared. All available data have been combined to provide a comprehensive set of liquidus slopes for impurities in ITS-90 metal fixed points. In total, liquidus slopes for 838 systems are tabulated for the fixed points Hg, Ga, In, Sn, Zn, Al, Ag, Au, and Cu. It is shown that the value of the liquidus slope as a function of impurity element atomic number can be approximated using a simple formula, and good qualitative agreement with the existing data is observed for the fixed points Al, Ag, Au and Cu, but curiously the formula is not applicable to the fixed points Hg, Ga, In, Sn, and Zn. Some discussion is made concerning the influence of oxygen on the liquidus slopes, and some calculations using MTDATA are discussed. The BIPM’s consultative committee for thermometry has long recognised that the sum of individual estimates method is the ideal approach for assessing uncertainties due to impurities, but the community has been largely powerless to use the model due to lack of data. Here, not only is data provided, but a simple model is given to enable known thermophysical data to be used directly to estimate impurity effects for a large fraction of the ITS-90 fixed points.
Combined GPS/GLONASS Precise Point Positioning with Fixed GPS Ambiguities
Pan, Lin; Cai, Changsheng; Santerre, Rock; Zhu, Jianjun
2014-01-01
Precise point positioning (PPP) technology is mostly implemented with an ambiguity-float solution. Its performance may be further improved by performing ambiguity-fixed resolution. Currently, the PPP integer ambiguity resolutions (IARs) are mainly based on GPS-only measurements. The integration of GPS and GLONASS can speed up the convergence and increase the accuracy of float ambiguity estimates, which contributes to enhancing the success rate and reliability of fixing ambiguities. This paper presents an approach of combined GPS/GLONASS PPP with fixed GPS ambiguities (GGPPP-FGA) in which GPS ambiguities are fixed into integers, while all GLONASS ambiguities are kept as float values. An improved minimum constellation method (MCM) is proposed to enhance the efficiency of GPS ambiguity fixing. Datasets from 20 globally distributed stations on two consecutive days are employed to investigate the performance of the GGPPP-FGA, including the positioning accuracy, convergence time and the time to first fix (TTFF). All datasets are processed for a time span of three hours in three scenarios, i.e., the GPS ambiguity-float solution, the GPS ambiguity-fixed resolution and the GGPPP-FGA resolution. The results indicate that the performance of the GPS ambiguity-fixed resolutions is significantly better than that of the GPS ambiguity-float solutions. In addition, the GGPPP-FGA improves the positioning accuracy by 38%, 25% and 44% and reduces the convergence time by 36%, 36% and 29% in the east, north and up coordinate components over the GPS-only ambiguity-fixed resolutions, respectively. Moreover, the TTFF is reduced by 27% after adding GLONASS observations. Wilcoxon rank sum tests and chi-square two-sample tests are made to examine the significance of the improvement on the positioning accuracy, convergence time and TTFF. PMID:25237901
Zhao, Jing; Zong, Haili
2018-01-01
In this paper, we propose parallel and cyclic iterative algorithms for solving the multiple-set split equality common fixed-point problem of firmly quasi-nonexpansive operators. We also combine the process of cyclic and parallel iterative methods and propose two mixed iterative algorithms. Our several algorithms do not need any prior information about the operator norms. Under mild assumptions, we prove weak convergence of the proposed iterative sequences in Hilbert spaces. As applications, we obtain several iterative algorithms to solve the multiple-set split equality problem.
Indirect Determination of the Thermodynamic Temperature of a Gold Fixed-Point Cell
NASA Astrophysics Data System (ADS)
Battuello, M.; Girard, F.; Florio, M.
2010-09-01
Since the value T 90(Au) was fixed on the ITS-90, some determinations of the thermodynamic temperature of the gold point have been performed which form, with other renormalized results of previous measurements by radiation thermometry, the basis for the current best estimates of ( T - T 90)Au = 39.9 mK as elaborated by the CCT-WG4. Such a value, even if consistent with the behavior of T - T 90 differences at lower temperatures, is quite influenced by the low values of T Au as determined with few radiometric measurements. At INRIM, an independent indirect determination of the thermodynamic temperature of gold was performed by means of a radiation thermometry approach. A fixed-point technique was used to realize approximated thermodynamic scales from the Zn point up to the Cu point. A Si-based standard radiation thermometer working at 900 nm and 950 nm was used. The low uncertainty presently associated to the thermodynamic temperature of fixed points and the accuracy of INRIM realizations, allowed scales with an uncertainty lower than 0.03 K in terms of the thermodynamic temperature to be realized. A fixed-point cell filled with gold, 99.999 % in purity, was measured, and its freezing temperature was determined by both interpolation and extrapolation. An average T Au = 1337.395 K was found with a combined standard uncertainty of 23 mK. Such a value is 25 mK higher than the presently available value as derived by the CCT-WG4 value of ( T - T 90)Au = 39.9 mK.
Two-point function of a d =2 quantum critical metal in the limit kF→∞ , Nf→0 with NfkF fixed
NASA Astrophysics Data System (ADS)
Säterskog, Petter; Meszena, Balazs; Schalm, Koenraad
2017-10-01
We show that the fermionic and bosonic spectrum of d =2 fermions at finite density coupled to a critical boson can be determined nonperturbatively in the combined limit kF→∞ ,Nf→0 with NfkF fixed. In this double scaling limit, the boson two-point function is corrected but only at one loop. This double scaling limit therefore incorporates the leading effect of Landau damping. The fermion two-point function is determined analytically in real space and numerically in (Euclidean) momentum space. The resulting spectrum is discontinuously connected to the quenched Nf→0 result. For ω →0 with k fixed the spectrum exhibits the distinct non-Fermi-liquid behavior previously surmised from the RPA approximation. However, the exact answer obtained here shows that the RPA result does not fully capture the IR of the theory.
Solution of the effective Hamiltonian of impurity hopping between two sites in a metal
NASA Astrophysics Data System (ADS)
Ye, Jinwu
1997-07-01
We analyze in detail all the possible fixed points of the effective Hamiltonian of a nonmagnetic impurity hopping between two sites in a metal obtained by Moustakas and Fisher (MF). We find a line of non-Fermi liquid fixed points which continuously interpolates between the two-channel Kondo fixed point (2CK) and the one-channel, two-impurity Kondo (2IK) fixed point. There is one relevant direction with scaling dimension 12 and one leading irrelevant operator with dimension 32. There is also one marginal operator in the spin sector moving along this line. The marginal operator, combined with the leading irrelevant operator, will generate the relevant operator. For the general position on this line, the leading low-temperature exponents of the specific heat, the hopping susceptibility and the electron conductivity Cimp,χhimp,σ(T) are the same as those of the 2CK, but the finite-size spectrum depends on the position on the line. No universal ratios can be formed from the amplitudes of the three quantities except at the 2CK point on this line where the universal ratios can be formed. At the 2IK point on this line, σ(T)~2σu(1+aT3/2), no universal ratio can be formed either. The additional non-Fermi-liquid fixed point found by MF has the same symmetry as the 2IK, it has two relevant directions with scaling dimension 12, and is therefore also unstable. The leading low-temperature behaviors are Cimp~T,χhimp~lnT,σ(T)~2σu(1+aT3/2) no universal ratios can be formed. The system is shown to flow to a line of Fermi-liquid fixed points which continuously interpolates between the noninteracting fixed point and the two-channel spin-flavor Kondo fixed point discussed by the author previously. The effect of particle-hole symmetry breaking is discussed. The effective Hamiltonian in the external magnetic field is analyzed. The scaling functions for the physical measurable quantities are derived in the different regimes; their predictions for the experiments are given. Finally the implications are given for a nonmagnetic impurity hopping around three sites with triangular symmetry discussed by MF.
NASA Technical Reports Server (NTRS)
Dejarnette, F. R.
1984-01-01
Concepts to save fuel while preserving airport capacity by combining time based metering with profile descent procedures were developed. A computer algorithm is developed to provide the flight crew with the information needed to fly from an entry fix to a metering fix and arrive there at a predetermined time, altitude, and airspeed. The flight from the metering fix to an aim point near the airport was calculated. The flight path is divided into several descent and deceleration segments. Descents are performed at constant Mach numbers or calibrated airspeed, whereas decelerations occur at constant altitude. The time and distance associated with each segment are calculated from point mass equations of motion for a clean configuration with idle thrust. Wind and nonstandard atmospheric properties have a large effect on the flight path. It is found that uncertainty in the descent Mach number has a large effect on the predicted flight time. Of the possible combinations of Mach number and calibrated airspeed for a descent, only small changes were observed in the fuel consumed.
Do fixed-dose combination pills or unit-of-use packaging improve adherence? A systematic review.
Connor, Jennie; Rafter, Natasha; Rodgers, Anthony
2004-01-01
Adequate adherence to medication regimens is central to the successful treatment of communicable and noncommunicable disease. Fixed-dose combination pills and unit-of-use packaging are therapy-related interventions that are designed to simplify medication regimens and so potentially improve adherence. We conducted a systematic review of relevant randomized trials in order to quantify the effects of fixed-dose combination pills and unit-of-use packaging, compared with medications as usually presented, in terms of adherence to treatment and improved outcomes. Only 15 trials met the inclusion criteria; fixed-dose combination pills were investigated in three of these, while unit-of-use packaging was studied in 12 trials. The trials involved treatments for communicable diseases (n = 5), blood pressure lowering medications (n = 3), diabetic patients (n = 1), vitamin supplementation (n = 1) and management of multiple medications by the elderly (n = 5). The results of the trials suggested that there were trends towards improved adherence and/or clinical outcomes in all but three of the trials; this reached statistical significance in four out of seven trials reporting a clinically relevant or intermediate end-point, and in seven out of thirteen trials reporting medication adherence. Measures of outcome were, however, heterogeneous, and interpretation was further limited by methodological issues, particularly small sample size, short duration and loss to follow-up. Overall, the evidence suggests that fixed-dose combination pills and unit-of-use packaging are likely to improve adherence in a range of settings, but the limitations of the available evidence means that uncertainty remains about the size of these benefits. PMID:15654408
Co-C and Pd-C Fixed Points for the Evaluation of Facilities and Scales Realization at INRIM and NMC
NASA Astrophysics Data System (ADS)
Battuello, M.; Wang, L.; Girard, F.; Ang, S. H.
2014-04-01
Two hybrid cells for realizing the Co-C and Pd-C fixed points and constructed at Istituto Nazionale di Ricerca Metrologica (INRIM) were used for an evaluation of facilities and procedures adopted by INRIM and National Metrology Institute of Singapore (NMC) for the realization of the solid-liquid phase transitions of high-temperature fixed points and for determining their transition temperatures. Four different furnaces were used for the investigations, i.e., two single-zone furnaces, one of them of the direct-heating type, and two identical three-zone furnaces. The transition temperatures were measured at both institutes by adopting different procedures for realizing the radiation scales, i.e., at INRIM a scheme based on the extrapolation of fixed-point interpolated scales and an International Temperature Scale of 1990 (ITS-90) approach at NMC. The point of inflection (POI) of the melting curves was determined and assumed as a practical representation of the melting temperature. Different methods for deriving the POI were used, and differences as large as some hundredths of a kelvin were found with the different approaches. The POIs of the different melting curves were analyzed with respect to the different possible operative conditions with the aim of deriving reproducibility figures to improve the estimated uncertainty. As regard to the institutes inter-comparison, differences of 0.13 K and 0.29 K were found between INRIM and NMC determinations at the Co-C and Pd-C points, respectively. Such differences are compatible with the combined standard uncertainties of the comparison, which are estimated to be 0.33 K and 0.36 K at the Co-C and Pd-C points, respectively.
Floating-to-Fixed-Point Conversion for Digital Signal Processors
NASA Astrophysics Data System (ADS)
Menard, Daniel; Chillet, Daniel; Sentieys, Olivier
2006-12-01
Digital signal processing applications are specified with floating-point data types but they are usually implemented in embedded systems with fixed-point arithmetic to minimise cost and power consumption. Thus, methodologies which establish automatically the fixed-point specification are required to reduce the application time-to-market. In this paper, a new methodology for the floating-to-fixed point conversion is proposed for software implementations. The aim of our approach is to determine the fixed-point specification which minimises the code execution time for a given accuracy constraint. Compared to previous methodologies, our approach takes into account the DSP architecture to optimise the fixed-point formats and the floating-to-fixed-point conversion process is coupled with the code generation process. The fixed-point data types and the position of the scaling operations are optimised to reduce the code execution time. To evaluate the fixed-point computation accuracy, an analytical approach is used to reduce the optimisation time compared to the existing methods based on simulation. The methodology stages are described and several experiment results are presented to underline the efficiency of this approach.
Shen, Chongfei; Liu, Hongtao; Xie, Xb; Luk, Keith Dk; Hu, Yong
2007-01-01
Adaptive noise canceller (ANC) has been used to improve signal to noise ratio (SNR) of somsatosensory evoked potential (SEP). In order to efficiently apply the ANC in hardware system, fixed-point algorithm based ANC can achieve fast, cost-efficient construction, and low-power consumption in FPGA design. However, it is still questionable whether the SNR improvement performance by fixed-point algorithm is as good as that by floating-point algorithm. This study is to compare the outputs of ANC by floating-point and fixed-point algorithm ANC when it was applied to SEP signals. The selection of step-size parameter (micro) was found different in fixed-point algorithm from floating-point algorithm. In this simulation study, the outputs of fixed-point ANC showed higher distortion from real SEP signals than that of floating-point ANC. However, the difference would be decreased with increasing micro value. In the optimal selection of micro, fixed-point ANC can get as good results as floating-point algorithm.
Hommer, A; Wickstrøm, J; Friis, M M; Steeds, C; Thygesen, J; Ferreras, A; Gouws, P; Buchholz, P
2008-04-01
To compare the efficacy and cost implications of the use of the intraocular pressure-lowering prostaglandin analogues bimatoprost, travoprost, and latanoprost as fixed-combination therapies with timolol, a beta-adrenergic receptor antagonist. A decision analytic cost-effectiveness model was constructed. Since no head-to-head studies comparing the three treatment options exist, the analysis was based on an indirect comparison. Hence, the model was based on efficacy data from five randomized, controlled, clinical studies. The studies were comparable with respect to study design, time horizon, patient population and type of end point presented. The measure of effectiveness was the percentage reduction of the intraocular pressure level from baseline. The cost evaluated was the cost of medication and clinical visits to the ophthalmologist. All drug costs were market prices inclusive of value-added tax, and visit costs were priced using official physician fees. Cost-effectiveness analyses were carried out in five European countries: Spain, Italy, United Kingdom, Norway and Sweden. The time horizon for the analyses was 3 months. The analysis showed that fixed-combination bimatoprost/timolol was more effective and less costly than fixed-combination travoprost/timolol and fixed-combination latanoprost/timolol in three out of the five countries analyzed. In two countries, bimatoprost/timolol was less costly than latanoprost/timolol, and cost the same as travoprost/timolol. This cost-effectiveness analysis showed that the fixed combination of bimatoprost 0.03%/timolol 0.5% administered once daily was a cost-effective treatment option for patients with primary open-angle glaucoma. This study was limited by available clinical data: without a head-to-head trial, indirect comparisons were necessary. In the United Kingdom, Sweden, Norway, Italy, and Spain, from a health service viewpoint, bimatoprost/timolol was a slightly more effective as well as less costly treatment strategy when compared to both travoprost/timolol and latanoprost/timolol.
Is scale-invariance in gauge-Yukawa systems compatible with the graviton?
NASA Astrophysics Data System (ADS)
Christiansen, Nicolai; Eichhorn, Astrid; Held, Aaron
2017-10-01
We explore whether perturbative interacting fixed points in matter systems can persist under the impact of quantum gravity. We first focus on semisimple gauge theories and show that the leading order gravity contribution evaluated within the functional Renormalization Group framework preserves the perturbative fixed-point structure in these models discovered in [J. K. Esbensen, T. A. Ryttov, and F. Sannino, Phys. Rev. D 93, 045009 (2016)., 10.1103/PhysRevD.93.045009]. We highlight that the quantum-gravity contribution alters the scaling dimension of the gauge coupling, such that the system exhibits an effective dimensional reduction. We secondly explore the effect of metric fluctuations on asymptotically safe gauge-Yukawa systems which feature an asymptotically safe fixed point [D. F. Litim and F. Sannino, J. High Energy Phys. 12 (2014) 178., 10.1007/JHEP12(2014)178]. The same effective dimensional reduction that takes effect in pure gauge theories also impacts gauge-Yukawa systems. There, it appears to lead to a split of the degenerate free fixed point into an interacting infrared attractive fixed point and a partially ultraviolet attractive free fixed point. The quantum-gravity induced infrared fixed point moves towards the asymptotically safe fixed point of the matter system, and annihilates it at a critical value of the gravity coupling. Even after that fixed-point annihilation, graviton effects leave behind new partially interacting fixed points for the matter sector.
Recall of patterns using binary and gray-scale autoassociative morphological memories
NASA Astrophysics Data System (ADS)
Sussner, Peter
2005-08-01
Morphological associative memories (MAM's) belong to a class of artificial neural networks that perform the operations erosion or dilation of mathematical morphology at each node. Therefore we speak of morphological neural networks. Alternatively, the total input effect on a morphological neuron can be expressed in terms of lattice induced matrix operations in the mathematical theory of minimax algebra. Neural models of associative memories are usually concerned with the storage and the retrieval of binary or bipolar patterns. Thus far, the emphasis in research on morphological associative memory systems has been on binary models, although a number of notable features of autoassociative morphological memories (AMM's) such as optimal absolute storage capacity and one-step convergence have been shown to hold in the general, gray-scale setting. In previous papers, we gained valuable insight into the storage and recall phases of AMM's by analyzing their fixed points and basins of attraction. We have shown in particular that the fixed points of binary AMM's correspond to the lattice polynomials in the original patterns. This paper extends these results in the following ways. In the first place, we provide an exact characterization of the fixed points of gray-scale AMM's in terms of combinations of the original patterns. Secondly, we present an exact expression for the fixed point attractor that represents the output of either a binary or a gray-scale AMM upon presentation of a certain input. The results of this paper are confirmed in several experiments using binary patterns and gray-scale images.
47 CFR 101.137 - Interconnection of private operational fixed point-to-point microwave stations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... point-to-point microwave stations. 101.137 Section 101.137 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.137 Interconnection of private operational fixed point-to-point microwave stations. Private...
47 CFR 101.137 - Interconnection of private operational fixed point-to-point microwave stations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... point-to-point microwave stations. 101.137 Section 101.137 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.137 Interconnection of private operational fixed point-to-point microwave stations. Private...
47 CFR 101.137 - Interconnection of private operational fixed point-to-point microwave stations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... point-to-point microwave stations. 101.137 Section 101.137 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.137 Interconnection of private operational fixed point-to-point microwave stations. Private...
47 CFR 101.137 - Interconnection of private operational fixed point-to-point microwave stations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... point-to-point microwave stations. 101.137 Section 101.137 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.137 Interconnection of private operational fixed point-to-point microwave stations. Private...
47 CFR 101.137 - Interconnection of private operational fixed point-to-point microwave stations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... point-to-point microwave stations. 101.137 Section 101.137 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.137 Interconnection of private operational fixed point-to-point microwave stations. Private...
NASA Astrophysics Data System (ADS)
Trung, Ha Duyen
2017-12-01
In this paper, the end-to-end performance of free-space optical (FSO) communication system combining with Amplify-and-Forward (AF)-assisted or fixed-gain relaying technology using subcarrier quadrature amplitude modulation (SC-QAM) over weak atmospheric turbulence channels modeled by log-normal distribution with pointing error impairments is studied. More specifically, unlike previous studies on AF relaying FSO communication systems without pointing error effects; the pointing error effect is studied by taking into account the influence of beamwidth, aperture size and jitter variance. In addition, a combination of these models to analyze the combined effect of atmospheric turbulence and pointing error to AF relaying FSO/SC-QAM systems is used. Finally, an analytical expression is derived to evaluate the average symbol error rate (ASER) performance of such systems. The numerical results show that the impact of pointing error on the performance of AF relaying FSO/SC-QAM systems and how we use proper values of aperture size and beamwidth to improve the performance of such systems. Some analytical results are confirmed by Monte-Carlo simulations.
Wall shear stress fixed points in blood flow
NASA Astrophysics Data System (ADS)
Arzani, Amirhossein; Shadden, Shawn
2017-11-01
Patient-specific computational fluid dynamics produces large datasets, and wall shear stress (WSS) is one of the most important parameters due to its close connection with the biological processes at the wall. While some studies have investigated WSS vectorial features, the WSS fixed points have not received much attention. In this talk, we will discuss the importance of WSS fixed points from three viewpoints. First, we will review how WSS fixed points relate to the flow physics away from the wall. Second, we will discuss how certain types of WSS fixed points lead to high biochemical surface concentration in cardiovascular mass transport problems. Finally, we will introduce a new measure to track the exposure of endothelial cells to WSS fixed points.
Effect of Impurities on the Freezing Point of Zinc
NASA Astrophysics Data System (ADS)
Sun, Jianping; Rudtsch, Steffen; Niu, Yalu; Zhang, Lin; Wang, Wei; Den, Xiaolong
2017-03-01
The knowledge of the liquidus slope of impurities in fixed-point metal defined by the International Temperature Scale of 1990 is important for the estimation of uncertainties and correction of fixed point with the sum of individual estimates method. Great attentions are paid to the effect of ultra-trace impurities on the freezing point of zinc in the National Institute of Metrology. In the present work, the liquidus slopes of Ga-Zn, Ge-Zn were measured with the slim fixed-point cell developed through the doping experiments, and the temperature characteristics of the phase diagram of Fe-Zn were furthermore investigated. A quasi-adiabatic Zn fixed-point cell was developed with the thermometer well surrounded by the crucible with the pure metal, and the temperature uniformity of less than 20 mK in the region where the metal is located was obtained. The previous doping experiment of Pb-Zn with slim fixed-point cell was checked with quasi-adiabatic Zn fixed-point cell, and the result supports the previous liquidus slope measured with the traditional fixed-point realization.
Common fixed points in best approximation for Banach operator pairs with Ciric type I-contractions
NASA Astrophysics Data System (ADS)
Hussain, N.
2008-02-01
The common fixed point theorems, similar to those of Ciric [Lj.B. Ciric, On a common fixed point theorem of a Gregus type, Publ. Inst. Math. (Beograd) (N.S.) 49 (1991) 174-178; Lj.B. Ciric, On Diviccaro, Fisher and Sessa open questions, Arch. Math. (Brno) 29 (1993) 145-152; Lj.B. Ciric, On a generalization of Gregus fixed point theorem, Czechoslovak Math. J. 50 (2000) 449-458], Fisher and Sessa [B. Fisher, S. Sessa, On a fixed point theorem of Gregus, Internat. J. Math. Math. Sci. 9 (1986) 23-28], Jungck [G. Jungck, On a fixed point theorem of Fisher and Sessa, Internat. J. Math. Math. Sci. 13 (1990) 497-500] and Mukherjee and Verma [R.N. Mukherjee, V. Verma, A note on fixed point theorem of Gregus, Math. Japon. 33 (1988) 745-749], are proved for a Banach operator pair. As applications, common fixed point and approximation results for Banach operator pair satisfying Ciric type contractive conditions are obtained without the assumption of linearity or affinity of either T or I. Our results unify and generalize various known results to a more general class of noncommuting mappings.
Miniature Fixed Points as Temperature Standards for In Situ Calibration of Temperature Sensors
NASA Astrophysics Data System (ADS)
Hao, X. P.; Sun, J. P.; Xu, C. Y.; Wen, P.; Song, J.; Xu, M.; Gong, L. Y.; Ding, L.; Liu, Z. L.
2017-06-01
Miniature Ga and Ga-In alloy fixed points as temperature standards are developed at National Institute of Metrology, China for the in situ calibration of temperature sensors. A quasi-adiabatic vacuum measurement system is constructed to study the phase-change plateaus of the fixed points. The system comprises a high-stability bath, a quasi-adiabatic vacuum chamber and a temperature control and measurement system. The melting plateau of the Ga fixed point is longer than 2 h at 0.008 W. The standard deviation of the melting temperature of the Ga and Ga-In alloy fixed points is better than 2 mK. The results suggest that the melting temperature of the Ga or Ga-In alloy fixed points is linearly related with the heating power.
Wall shear stress fixed points in cardiovascular fluid mechanics.
Arzani, Amirhossein; Shadden, Shawn C
2018-05-17
Complex blood flow in large arteries creates rich wall shear stress (WSS) vectorial features. WSS acts as a link between blood flow dynamics and the biology of various cardiovascular diseases. WSS has been of great interest in a wide range of studies and has been the most popular measure to correlate blood flow to cardiovascular disease. Recent studies have emphasized different vectorial features of WSS. However, fixed points in the WSS vector field have not received much attention. A WSS fixed point is a point on the vessel wall where the WSS vector vanishes. In this article, WSS fixed points are classified and the aspects by which they could influence cardiovascular disease are reviewed. First, the connection between WSS fixed points and the flow topology away from the vessel wall is discussed. Second, the potential role of time-averaged WSS fixed points in biochemical mass transport is demonstrated using the recent concept of Lagrangian WSS structures. Finally, simple measures are proposed to quantify the exposure of the endothelial cells to WSS fixed points. Examples from various arterial flow applications are demonstrated. Copyright © 2018 Elsevier Ltd. All rights reserved.
47 CFR 101.101 - Frequency availability.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE...—(Part 78) CC: Common Carrier Fixed Point-to-Point Microwave Service—(Part 101, Subparts C & I) DBS... Distribution Service—(Part 21) OFS: Private Operational Fixed Point-to-Point Microwave Service—(Part 101...
47 CFR 101.101 - Frequency availability.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE...—(Part 78) CC: Common Carrier Fixed Point-to-Point Microwave Service—(Part 101, Subparts C & I) DBS... Distribution Service—(Part 21) OFS: Private Operational Fixed Point-to-Point Microwave Service—(Part 101...
47 CFR 101.21 - Technical content of applications.
Code of Federal Regulations, 2013 CFR
2013-10-01
... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses General Filing Requirements § 101.21 Technical... Private Operational Fixed Point-to-Point Microwave Service and the Common Carrier Fixed Point-to-Point Microwave Service must include the following information: Applicant's name and address. Transmitting station...
47 CFR 101.21 - Technical content of applications.
Code of Federal Regulations, 2014 CFR
2014-10-01
... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses General Filing Requirements § 101.21 Technical... Private Operational Fixed Point-to-Point Microwave Service and the Common Carrier Fixed Point-to-Point Microwave Service must include the following information: Applicant's name and address. Transmitting station...
47 CFR 101.107 - Frequency tolerance.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE... to private operational fixed point-to-point microwave and stations providing MVDDS. 5 For private operational fixed point-to-point microwave systems, with a channel greater than or equal to 50 KHz bandwidth...
47 CFR 101.101 - Frequency availability.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE...—(Part 78) CC: Common Carrier Fixed Point-to-Point Microwave Service—(Part 101, Subparts C & I) DBS... Distribution Service—(Part 21) OFS: Private Operational Fixed Point-to-Point Microwave Service—(Part 101...
Songbird - AN Innovative Uas Combining the Advantages of Fixed Wing and Multi Rotor Uas
NASA Astrophysics Data System (ADS)
Thamm, F.-P.; Brieger, N.; Neitzke, K.-P.; Meyer, M.; Jansen, R.; Mönninghof, M.
2015-08-01
This paper describes a family of innovative fixed wing UAS with can vertical take off and land - the SONGBIRD family. With nominal payloads starting from 0.5 kg they can take off and land safely like a multi-rotor UAV, removing the need for an airstrip for the critical phases of operation. A specially designed flight controller allows stable flight at every point of the transition phase between VTOL and fixed wing mode. Because of this smooth process with a all time stable flight, very expensive payload like hyperspectral sensors or advanced optical cameras can be used. Due to their design all airplanes of the SONGBIRD family have excellent horizontal flight properties, a maximum speed of over 110 km/h, good gliding properties and long flight times of up to 1 h. Missions were flown in wind speeds up to 18 m/s. At every time of the flight it is possible to interrupt the mission and hover over a point of interest for detail investigations. The complete flight, including take-off and landing can be performed by autopilot. Designed for daily use in professional environments, SONGBIRDs are built out of glass-fibre and carbon composites for a long service life. For safe operations comprehensive security features are implemented, for example redundant flight controllers and sensors, advanced power management system and mature fail safe procedures. The aircraft can be dismantled into small parts for transportation. SONGBIRDS are available for different pay loads, from 500 g to 2 kg. The SONGBIRD family are interesting tools combining the advantages of multi-copter and fixed wing UAS.
Suzuki, Emilio Rintaro; Suzuki, Cibele Lima Belico
2010-01-01
Travoprost is a prostaglandin analog used in the management of glaucoma and ocular hypertension for reducing intraocular pressure (IOP). The IOP-lowering efficacy of travoprost has been shown to be similar to that of other prostaglandins, including latanoprost and bimatoprost. When compared with fixed combinations of timolol and either latanoprost or dorzolamide, travoprost alone can reduce mean IOP in a similar or superior manner. Concomitant therapy of travoprost and timolol can reach even greater IOP reductions than fixed combinations at some time points, but with no difference in the early morning, when IOP is usually higher. In addition, the long duration of action of travoprost can also provide better control of IOP fluctuation, probably due to its stronger prostaglandin F receptor mechanism. The side effects of travoprost do not represent a risk to the vision or health of the patient. The proven efficacy and safety combined with convenient once-daily dosing for travoprost increases patient compliance with treatment for glaucoma. PMID:21060666
Seeking fixed points in multiple coupling scalar theories in the ɛ expansion
NASA Astrophysics Data System (ADS)
Osborn, Hugh; Stergiou, Andreas
2018-05-01
Fixed points for scalar theories in 4 - ɛ, 6 - ɛ and 3 - ɛ dimensions are discussed. It is shown how a large range of known fixed points for the four dimensional case can be obtained by using a general framework with two couplings. The original maximal symmetry, O( N), is broken to various subgroups, both discrete and continuous. A similar discussion is applied to the six dimensional case. Perturbative applications of the a-theorem are used to help classify potential fixed points. At lowest order in the ɛ-expansion it is shown that at fixed points there is a lower bound for a which is saturated at bifurcation points.
Three Boundary Conditions for Computing the Fixed-Point Property in Binary Mixture Data.
van Maanen, Leendert; Couto, Joaquina; Lebreton, Mael
2016-01-01
The notion of "mixtures" has become pervasive in behavioral and cognitive sciences, due to the success of dual-process theories of cognition. However, providing support for such dual-process theories is not trivial, as it crucially requires properties in the data that are specific to mixture of cognitive processes. In theory, one such property could be the fixed-point property of binary mixture data, applied-for instance- to response times. In that case, the fixed-point property entails that response time distributions obtained in an experiment in which the mixture proportion is manipulated would have a common density point. In the current article, we discuss the application of the fixed-point property and identify three boundary conditions under which the fixed-point property will not be interpretable. In Boundary condition 1, a finding in support of the fixed-point will be mute because of a lack of difference between conditions. Boundary condition 2 refers to the case in which the extreme conditions are so different that a mixture may display bimodality. In this case, a mixture hypothesis is clearly supported, yet the fixed-point may not be found. In Boundary condition 3 the fixed-point may also not be present, yet a mixture might still exist but is occluded due to additional changes in behavior. Finding the fixed-property provides strong support for a dual-process account, yet the boundary conditions that we identify should be considered before making inferences about underlying psychological processes.
Three Boundary Conditions for Computing the Fixed-Point Property in Binary Mixture Data
Couto, Joaquina; Lebreton, Mael
2016-01-01
The notion of “mixtures” has become pervasive in behavioral and cognitive sciences, due to the success of dual-process theories of cognition. However, providing support for such dual-process theories is not trivial, as it crucially requires properties in the data that are specific to mixture of cognitive processes. In theory, one such property could be the fixed-point property of binary mixture data, applied–for instance- to response times. In that case, the fixed-point property entails that response time distributions obtained in an experiment in which the mixture proportion is manipulated would have a common density point. In the current article, we discuss the application of the fixed-point property and identify three boundary conditions under which the fixed-point property will not be interpretable. In Boundary condition 1, a finding in support of the fixed-point will be mute because of a lack of difference between conditions. Boundary condition 2 refers to the case in which the extreme conditions are so different that a mixture may display bimodality. In this case, a mixture hypothesis is clearly supported, yet the fixed-point may not be found. In Boundary condition 3 the fixed-point may also not be present, yet a mixture might still exist but is occluded due to additional changes in behavior. Finding the fixed-property provides strong support for a dual-process account, yet the boundary conditions that we identify should be considered before making inferences about underlying psychological processes. PMID:27893868
47 CFR 101.21 - Technical content of applications.
Code of Federal Regulations, 2010 CFR
2010-10-01
... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses General Filing Requirements § 101.21 Technical...) [Reserved] (e) Each application in the Private Operational Fixed Point-to-Point Microwave Service and the Common Carrier Fixed Point-to-Point Microwave Service must include the following information: Applicant's...
47 CFR 101.5 - Station authorization required.
Code of Federal Regulations, 2014 CFR
2014-10-01
... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses General Filing Requirements § 101.5 Station... stations authorized under subpart H (Private Operational Fixed Point-to-Point Microwave Service), subpart I (Common Carrier Fixed Point-to-Point Microwave Service), and subpart L of this part (Local Multipoint...
47 CFR 101.5 - Station authorization required.
Code of Federal Regulations, 2010 CFR
2010-10-01
... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses General Filing Requirements § 101.5 Station... stations authorized under subpart H (Private Operational Fixed Point-to-Point Microwave Service), subpart I (Common Carrier Fixed Point-to-Point Microwave Service), and subpart L of this part (Local Multipoint...
47 CFR 101.21 - Technical content of applications.
Code of Federal Regulations, 2011 CFR
2011-10-01
... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses General Filing Requirements § 101.21 Technical...) [Reserved] (e) Each application in the Private Operational Fixed Point-to-Point Microwave Service and the Common Carrier Fixed Point-to-Point Microwave Service must include the following information: Applicant's...
47 CFR 101.21 - Technical content of applications.
Code of Federal Regulations, 2012 CFR
2012-10-01
... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses General Filing Requirements § 101.21 Technical...) [Reserved] (e) Each application in the Private Operational Fixed Point-to-Point Microwave Service and the Common Carrier Fixed Point-to-Point Microwave Service must include the following information: Applicant's...
47 CFR 101.5 - Station authorization required.
Code of Federal Regulations, 2013 CFR
2013-10-01
... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses General Filing Requirements § 101.5 Station... stations authorized under subpart H (Private Operational Fixed Point-to-Point Microwave Service), subpart I (Common Carrier Fixed Point-to-Point Microwave Service), and subpart L of this part (Local Multipoint...
47 CFR 101.5 - Station authorization required.
Code of Federal Regulations, 2012 CFR
2012-10-01
... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses General Filing Requirements § 101.5 Station... stations authorized under subpart H (Private Operational Fixed Point-to-Point Microwave Service), subpart I (Common Carrier Fixed Point-to-Point Microwave Service), and subpart L of this part (Local Multipoint...
47 CFR 101.5 - Station authorization required.
Code of Federal Regulations, 2011 CFR
2011-10-01
... SERVICES FIXED MICROWAVE SERVICES Applications and Licenses General Filing Requirements § 101.5 Station... stations authorized under subpart H (Private Operational Fixed Point-to-Point Microwave Service), subpart I (Common Carrier Fixed Point-to-Point Microwave Service), and subpart L of this part (Local Multipoint...
[Combination therapy in the medical treatment of glaucoma].
Hommer, A
2013-02-01
A combination of antiglaucoma medications is indicated if monotherapy is not sufficient to achieve the predefined target pressure and/or in case of a progression of glaucomatous damage or conversion from ocular hypertension to glaucomatous optic neuropathy. Most recently many fixed combinations with two active compounds have become available for the medical treatment of glaucoma. Compared to non-fixed combinations, these drugs offer a much easier use for the patients. Fixed combinations have to be applied less frequently which may improve adherence. Furthermore, they most likely contain a lower amount of toxic preservatives compared to non-fixed combinations. And finally, fixed combinations may eliminate the risk of a "washout" of the first medication by using the second product of a non-fixed combination too soon after the first drop has been installed. This review aims to examine the most important aspects of IOP-lowering fixed and non-fixed combinations in glaucoma management with a clear focus on the results obtained with fixed combinations. In Germany, fixed combinations with the compositions dorzolamide/timolol (FCDT), brinzolamide/timolol (FCBRINT), latanoprost/timolol (FCLT), travoprost/timolol (FCTT), bimatoprost/timolol (FCBIMT), brimonidine/timolol (FCBT), pilocarpine/timolol (FCPT) and metipranolol/timolol (FCMT) are approved for the medical management of glaucoma and ocular hypertension. The results of clinical studies comparing fixed combinations with their active ingredients and with the corresponding non-fixed combinations will be discussed. Furthermore - if available - the results of direct comparisons of the efficacy and safety of different IOP-lowering fixed combinations are summarised. Georg Thieme Verlag KG Stuttgart · New York.
Suić, Smiljka Popović; Laus, Katia Novak; Dosen, Vukosava Maricic; Ekert, Miroslav; Mandić, Zdravko; Bojić, Lovro
2010-09-01
An open label, multi-center, 6 months observational study of new fixed combination (travoprost 0.004%/timolol 0.5%), in order to evaluate both efficacy (intraocular pressure lowering) and tolerability (patient and investigator satisfaction) of two dosing regimens--evening (PM) and morning (AM). After screening for enrollment, to 40 patients (79 eyes with primary open angle glaucoma or ocular hypertension), new fixed combination travoprost 0.004%/timolol 0.5% was prescribed once a day in the evening (PM). Patients were enrolled according to each investigator decision on indication for travoprost 0.004%/timolol 0.5% fixed combination once a day, without washout period after previous medication. Intraocular pressure was measured at 9 AM at all time control points: at baseline, after 1 month, after 3 months and after 6 month. After 1 month, screening for nonresponders (criteria: 20% intraocular pressure lowering) and subjects with major side effects was performed. At second control visit, after 3 months PM dosing, intraocular pressure was measured and patients were instructed to continue once a day the same medication, but in the morning (AM) for consequent 3 months. After 1 month, reduction in mean intraocular pressure value was 21.66%. At the visit after 3 month, the mean intraocular pressure was 15.67 +/- 2.17 mm Hg (reduction 21.14%). 3 month after dosing regimen changed to AM (6 month after beginning of travoprost 0.004%/timolol 0.5% combination therapy), reduction in intraocular pressure value was 19.86%. The differences (mean +/- standard deviation) in intraocular pressure values after 1, 3 and 6 month were all highly statistically significant compared to baseline values. The tolerability was evaluated in five steps (Likert scale) ranging from unsatisfactory to excellent by both patient and investigator--taken at 3 and 6 month control visit. 95% of patients and 100% of investigators were satisfied with the possibility of choosing dosing regimen for travoprost 0.004%/timolol 0.5% fixed combination. Travoprost 0.004%/timolol 0.5% fixed combination proved sufficient intraocular pressure control dosed either PM or AM with no statistically significant difference between two dosing regimens. Possibility to choose between two dosing regimens gives each practitioner additional reassurance that glaucoma therapy will be individualised to needs of each patient.
NASA Astrophysics Data System (ADS)
Abbasi, R. U.; Abu-Zayyad, T.; Amann, J. F.; Archbold, G.; Atkins, R.; Bellido, J. A.; Belov, K.; Belz, J. W.; Ben-Zvi, S. Y.; Bergman, D. R.; Boyer, J. H.; Burt, G. W.; Cao, Z.; Clay, R. W.; Connolly, B. M.; Dawson, B. R.; Deng, W.; Farrar, G. R.; Fedorova, Y.; Findlay, J.; Finley, C. B.; Hanlon, W. F.; Hoffman, C. M.; Holzscheiter, M. H.; Hughes, G. A.; Hüntemeyer, P.; Jui, C. C. H.; Kim, K.; Kirn, M. A.; Knapp, B. C.; Loh, E. C.; Maestas, M. M.; Manago, N.; Mannel, E. J.; Marek, L. J.; Martens, K.; Matthews, J. A. J.; Matthews, J. N.; O'Neill, A.; Painter, C. A.; Perera, L.; Reil, K.; Riehle, R.; Roberts, M. D.; Sasaki, M.; Schnetzer, S. R.; Seman, M.; Simpson, K. M.; Sinnis, G.; Smith, J. D.; Snow, R.; Sokolsky, P.; Song, C.; Springer, R. W.; Stokes, B. T.; Thomas, J. R.; Thomas, S. B.; Thomson, G. B.; Tupa, D.; Westerhoff, S.; Wiencke, L. R.; Zech, A.
2005-04-01
We present the results of a search for cosmic-ray point sources at energies in excess of 4.0×1019 eV in the combined data sets recorded by the Akeno Giant Air Shower Array and High Resolution Fly's Eye stereo experiments. The analysis is based on a maximum likelihood ratio test using the probability density function for each event rather than requiring an a priori choice of a fixed angular bin size. No statistically significant clustering of events consistent with a point source is found.
Neri, L; Miracapillo, A
2015-02-01
Topical corticosteroids and the vitamin D analogue calcipotriol are the cornerstone of therapy for patients with mild-to-moderate plaque psoriasis. Lack of patients' adherence leads to suboptimal effectiveness of topical therapy in real-life practice. The fixed combination betamethasone/calcipotriol gel is more effective and safe than the administration of single components and may enhance patients' adherence. We aimed at evaluating the pattern of care and dermatologists' expert opinion toward the available topical treatments for the management of mild-to-moderate psoriasis in Italy. We enrolled 242 Italian dermatologists and collected information related to their practice pattern and opinion toward available topical treatments with a face-to-face structured interview. We evaluated dermatologists' ratings of therapy with 16 items tapping their opinion toward the relevance and satisfaction toward 8 therapy attributes in clinical practices which tapped aspects of real-life effectiveness, adherence promotion, toxicity, convenience of use. Ratings occurred along a 10-point scale. We compared single-attribute and weighted overall therapy ratings across alternative treatment options with random-intercept linear models to account for ratings clustering within dermatologists. There was a wide variation in practice patterns: 1/3 of dermatologist had seen more than 30 patients with psoriasis while around 1/4 had seen less than 10 patients. The fixed combination betamethasone/calcipotriol gel was considered superior to monotherapies in all the eight attributes considered which tapped aspects of real-life effectiveness, adherence promotion, toxicity, convenience of use. Participant dermatologists' strongly preferred the fixed betamethasone/calcipotriol combination gel over both the fixed combination ointment formulation and corticosteroid or vitamin D analogues monotherapies. Such findings are in line with evidence from randomized controlled trials and few observational studies demonstrating superior clinical outcomes, quality of life, tolerability and lower risk of side effect in patients treated with the fixed combination of betamethasone/calcipotriol gel.
Solution of effective Hamiltonian of impurity hopping between two sites in a metal
NASA Astrophysics Data System (ADS)
Ye, Jinwu
1998-03-01
We analyze in detail all the possible fixed points of the effective Hamiltonian of a non-magnetic impurity hopping between two sites in a metal obtained by Moustakas and Fisher(MF). We find a line of non-fermi liquid fixed points which continuously interpolates between the 2-channel Kondo fixed point(2CK) and the one channel, two impurity Kondo (2IK) fixed point. There is one relevant direction with scaling dimension 1/2 and one leading irrelevant operator with dimension 3/2. There is also one marginal operator in the spin sector moving along this line. The additional non-fermi liquid fixed point found by MF has the same symmetry as the 2IK, it has two relevant directions with scaling dimension 1/2, therefore also unstable. The system is shown to flow to a line of fermi-liquid fixed points which continuously interpolates between the non-interacting fixed point and the 2 channel spin-flavor Kondo fixed point (2CSFK) discussed by the author previously. The effect of particle-hole symmetry breaking is discussed. The effective Hamiltonian in the external magnetic field is analysed. The scaling functions for the physical measurable quantities are derived in the different regimes; their predictions for the experiments are given. Finally the implications are given for a non-magnetic impurity hopping around three sites with triangular symmetry discussed by MF.
1989-06-09
Theorem and the Perron - Frobenius Theorem in matrix theory. We use the Hahn-Banach theorem and do not use any fixed-point related concepts. 179 A...games defined b’, tions 87 Isac G. Fixed point theorems on convex cones , generalized pseudo-contractive mappings and the omplementarity problem 89...and (II), af(x) ° denotes the negative polar cone ot of(x). This condition are respectively called "inward" and "outward". Indeed, when X is convex
The combined mode of action of fipronil and amitraz on the motility of Rhipicephalus sanguineus.
Prullage, Joseph B; Tran, Hai V; Timmons, Phil; Harriman, Jay; Chester, S Theodore; Powell, Kerrie
2011-07-15
The motility of adult Rhipicephalus sanguineus was evaluated subsequent to treatments of amitraz, fipronil and the combination of fipronil plus amitraz against a vehicle control in a Petri dish assay using the LemnaTec Scanalyzer Imaging System. The assay was run using a fixed dilution of amitraz (0.32μg/cm(2)); serial dilutions of fipronil (1.3, 0.33, 0.08, 0.02, or 0.005μg/cm(2)); and the same serial dilutions of fipronil in combination with the fixed dilution of amitraz. Measurement of motility was made of unstimulated ticks and then after stimulation at 1, 4, 18-22, and 24h post exposure (hpe) of the Petri dishes. For the unstimulated ticks, there was no difference in motility between the amitraz treatment group and the fipronil plus amitraz treatment group at the early time points. However, these two treatment groups had significantly higher motility than the solvent control and fipronil treatment groups. The unstimulated ticks in the amitraz treatment group had significantly higher motility than the fipronil plus amitraz treatment group at the later time points. Measurements after stimulation demonstrated there was no difference in motility between the amitraz treatment group and the fipronil plus amitraz treatment group at the early time points. By 18 hpe, the fipronil plus amitraz treatment group had significantly lower motility than all other treatment groups and at 21-22 and 24 hpe the other treatment groups did not differ from the control group. The action could be divided in two phases in the combination experiment: phase 1: an early increase in motility due to amitraz is identified in both amitraz alone or fipronil plus amitraz groups; phase 2: the combination of fipronil plus amitraz caused a significantly greater reduction in motility, suggesting mortality of the ticks, compared to fipronil or amitraz alone. These results demonstrate a synergism resulting from the combination of fipronil plus amitraz. Copyright © 2011 Elsevier B.V. All rights reserved.
Implicit Contractive Mappings in Modular Metric and Fuzzy Metric Spaces
Hussain, N.; Salimi, P.
2014-01-01
The notion of modular metric spaces being a natural generalization of classical modulars over linear spaces like Lebesgue, Orlicz, Musielak-Orlicz, Lorentz, Orlicz-Lorentz, and Calderon-Lozanovskii spaces was recently introduced. In this paper we investigate the existence of fixed points of generalized α-admissible modular contractive mappings in modular metric spaces. As applications, we derive some new fixed point theorems in partially ordered modular metric spaces, Suzuki type fixed point theorems in modular metric spaces and new fixed point theorems for integral contractions. In last section, we develop an important relation between fuzzy metric and modular metric and deduce certain new fixed point results in triangular fuzzy metric spaces. Moreover, some examples are provided here to illustrate the usability of the obtained results. PMID:25003157
Kitazawa, Y; Smith, P; Sasaki, N; Kotake, S; Bae, K; Iwamoto, Y
2011-01-01
Purpose The purpose of this study is to compare the safety and intraocular pressure (IOP)-lowering efficacy of travoprost/timolol in a benzalkonium chloride (BAK)-free fixed combination preserved with polyquaternium-1 (TRA/TIM BAK-free), with travoprost/timolol-fixed combination preserved with BAK (TRA/TIM), in patients with open-angle glaucoma or ocular hypertension. Methods In this prospective randomized controlled trial, subjects with IOP of at least 22 mm Hg in one or both eyes at 0900 h, and IOP of at least 21 mm Hg in one or both eyes at 1100 h and 1600 h at two eligibility visits were randomly assigned to receive either TRA/TIM BAK-free (n=195) or TRA/TIM (n=193), dosed once daily in the morning (0900 h) for 6 weeks. IOP was assessed at 0900 h, 1100 h, and 1600 h at each scheduled visit (baseline, 2 and 6 weeks after randomization). Results Mean IOP reduction across all visits and time points was 8.0 mm Hg in the TRA/TIM BAK-free group and 8.4 mm Hg in the TRA/TIM group (P=0.0943). The difference in mean IOP between groups ranged from 0.2 to 0.7 mm Hg across visits and time points, with a mean pooled difference of 0.4 mm Hg (95% CI: −0.1 to 0.8), demonstrating equivalence of the two formulations. The most common drug-related adverse event was hyperemia of the eye (ocular hyperemia and conjunctival hyperemia combined), occurring in 11.8% of the TRA/TIM BAK-free group and 13.0% of the TRA/TIM group. Conclusion Travoprost/timolol BAK-free demonstrated equivalence to travoprost/timolol preserved with BAK in efficacy. No clinically relevant differences in the safety profiles of travoprost/timolol BAK-free and travoprost/timolol preserved with BAK were identified. PMID:21701528
Kitazawa, Y; Smith, P; Sasaki, N; Kotake, S; Bae, K; Iwamoto, Y
2011-09-01
The purpose of this study is to compare the safety and intraocular pressure (IOP)-lowering efficacy of travoprost/timolol in a benzalkonium chloride (BAK)-free fixed combination preserved with polyquaternium-1 (TRA/TIM BAK-free), with travoprost/timolol-fixed combination preserved with BAK (TRA/TIM), in patients with open-angle glaucoma or ocular hypertension. In this prospective randomized controlled trial, subjects with IOP of at least 22 mm Hg in one or both eyes at 0900 h, and IOP of at least 21 mm Hg in one or both eyes at 1100 h and 1600 h at two eligibility visits were randomly assigned to receive either TRA/TIM BAK-free (n=195) or TRA/TIM (n=193), dosed once daily in the morning (0900 h) for 6 weeks. IOP was assessed at 0900 h, 1100 h, and 1600 h at each scheduled visit (baseline, 2 and 6 weeks after randomization). Mean IOP reduction across all visits and time points was 8.0 mm Hg in the TRA/TIM BAK-free group and 8.4 mm Hg in the TRA/TIM group (P=0.0943). The difference in mean IOP between groups ranged from 0.2 to 0.7 mm Hg across visits and time points, with a mean pooled difference of 0.4 mm Hg (95% CI: -0.1 to 0.8), demonstrating equivalence of the two formulations. The most common drug-related adverse event was hyperemia of the eye (ocular hyperemia and conjunctival hyperemia combined), occurring in 11.8% of the TRA/TIM BAK-free group and 13.0% of the TRA/TIM group. Travoprost/timolol BAK-free demonstrated equivalence to travoprost/timolol preserved with BAK in efficacy. No clinically relevant differences in the safety profiles of travoprost/timolol BAK-free and travoprost/timolol preserved with BAK were identified.
Automated system for measuring temperature profiles inside ITS-90 fixed-point cells
NASA Astrophysics Data System (ADS)
Hiti, Miha; Bojkovski, Jovan; Batagelj, Valentin; Drnovsek, Janko
2005-11-01
The defining fixed points of the International Temperature Scale of 1990 (ITS-90) are temperature reference points for temperature calibration. The measured temperature inside the fixed-point cell depends on thermometer immersion, since measurements are made below the surface of the fixed-point material and the additional effect of the hydrostatic pressure has to be taken into account. Also, the heat flux along the thermometer stem can affect the measured temperature. The paper presents a system that enables accurate and reproducible immersion profile measurements for evaluation of measurement sensitivity and adequacy of thermometer immersion. It makes immersion profile measurements possible, where a great number of repetitions and long measurement periods are required, and reduces the workload on the user for performing such measurements. The system is flexible and portable and was developed for application to existing equipment in the laboratory. Results of immersion profile measurements in a triple point of water fixed-point cell are presented.
Rapid evolution of cis-regulatory sequences via local point mutations
NASA Technical Reports Server (NTRS)
Stone, J. R.; Wray, G. A.
2001-01-01
Although the evolution of protein-coding sequences within genomes is well understood, the same cannot be said of the cis-regulatory regions that control transcription. Yet, changes in gene expression are likely to constitute an important component of phenotypic evolution. We simulated the evolution of new transcription factor binding sites via local point mutations. The results indicate that new binding sites appear and become fixed within populations on microevolutionary timescales under an assumption of neutral evolution. Even combinations of two new binding sites evolve very quickly. We predict that local point mutations continually generate considerable genetic variation that is capable of altering gene expression.
Learning in the Machine: Random Backpropagation and the Deep Learning Channel.
Baldi, Pierre; Sadowski, Peter; Lu, Zhiqin
2018-07-01
Random backpropagation (RBP) is a variant of the backpropagation algorithm for training neural networks, where the transpose of the forward matrices are replaced by fixed random matrices in the calculation of the weight updates. It is remarkable both because of its effectiveness, in spite of using random matrices to communicate error information, and because it completely removes the taxing requirement of maintaining symmetric weights in a physical neural system. To better understand random backpropagation, we first connect it to the notions of local learning and learning channels. Through this connection, we derive several alternatives to RBP, including skipped RBP (SRPB), adaptive RBP (ARBP), sparse RBP, and their combinations (e.g. ASRBP) and analyze their computational complexity. We then study their behavior through simulations using the MNIST and CIFAR-10 bechnmark datasets. These simulations show that most of these variants work robustly, almost as well as backpropagation, and that multiplication by the derivatives of the activation functions is important. As a follow-up, we study also the low-end of the number of bits required to communicate error information over the learning channel. We then provide partial intuitive explanations for some of the remarkable properties of RBP and its variations. Finally, we prove several mathematical results, including the convergence to fixed points of linear chains of arbitrary length, the convergence to fixed points of linear autoencoders with decorrelated data, the long-term existence of solutions for linear systems with a single hidden layer and convergence in special cases, and the convergence to fixed points of non-linear chains, when the derivative of the activation functions is included.
Fixed point theorems and dissipative processes
NASA Technical Reports Server (NTRS)
Hale, J. K.; Lopes, O.
1972-01-01
The deficiencies of the theories that characterize the maximal compact invariant set of T as asymptotically stable, and that some iterate of T has a fixed point are discussed. It is shown that this fixed point condition is always satisfied for condensing and local dissipative T. Applications are given to a class of neutral functional differential equations.
Verification and Planning Based on Coinductive Logic Programming
NASA Technical Reports Server (NTRS)
Bansal, Ajay; Min, Richard; Simon, Luke; Mallya, Ajay; Gupta, Gopal
2008-01-01
Coinduction is a powerful technique for reasoning about unfounded sets, unbounded structures, infinite automata, and interactive computations [6]. Where induction corresponds to least fixed point's semantics, coinduction corresponds to greatest fixed point semantics. Recently coinduction has been incorporated into logic programming and an elegant operational semantics developed for it [11, 12]. This operational semantics is the greatest fix point counterpart of SLD resolution (SLD resolution imparts operational semantics to least fix point based computations) and is termed co- SLD resolution. In co-SLD resolution, a predicate goal p( t) succeeds if it unifies with one of its ancestor calls. In addition, rational infinite terms are allowed as arguments of predicates. Infinite terms are represented as solutions to unification equations and the occurs check is omitted during the unification process. Coinductive Logic Programming (Co-LP) and Co-SLD resolution can be used to elegantly perform model checking and planning. A combined SLD and Co-SLD resolution based LP system forms the common basis for planning, scheduling, verification, model checking, and constraint solving [9, 4]. This is achieved by amalgamating SLD resolution, co-SLD resolution, and constraint logic programming [13] in a single logic programming system. Given that parallelism in logic programs can be implicitly exploited [8], complex, compute-intensive applications (planning, scheduling, model checking, etc.) can be executed in parallel on multi-core machines. Parallel execution can result in speed-ups as well as in larger instances of the problems being solved. In the remainder we elaborate on (i) how planning can be elegantly and efficiently performed under real-time constraints, (ii) how real-time systems can be elegantly and efficiently model- checked, as well as (iii) how hybrid systems can be verified in a combined system with both co-SLD and SLD resolution. Implementations of co-SLD resolution as well as preliminary implementations of the planning and verification applications have been developed [4]. Co-LP and Model Checking: The vast majority of properties that are to be verified can be classified into safety properties and liveness properties. It is well known within model checking that safety properties can be verified by reachability analysis, i.e, if a counter-example to the property exists, it can be finitely determined by enumerating all the reachable states of the Kripke structure.
Common fixed point theorems for maps under a contractive condition of integral type
NASA Astrophysics Data System (ADS)
Djoudi, A.; Merghadi, F.
2008-05-01
Two common fixed point theorems for mapping of complete metric space under a general contractive inequality of integral type and satisfying minimal commutativity conditions are proved. These results extend and improve several previous results, particularly Theorem 4 of Rhoades [B.E. Rhoades, Two fixed point theorems for mappings satisfying a general contractive condition of integral type, Int. J. Math. Math. Sci. 63 (2003) 4007-4013] and Theorem 4 of Sessa [S. Sessa, On a weak commutativity condition of mappings in fixed point considerations, Publ. Inst. Math. (Beograd) (N.S.) 32 (46) (1982) 149-153].
Periodicity and stability for variable-time impulsive neural networks.
Li, Hongfei; Li, Chuandong; Huang, Tingwen
2017-10-01
The paper considers a general neural networks model with variable-time impulses. It is shown that each solution of the system intersects with every discontinuous surface exactly once via several new well-proposed assumptions. Moreover, based on the comparison principle, this paper shows that neural networks with variable-time impulse can be reduced to the corresponding neural network with fixed-time impulses under well-selected conditions. Meanwhile, the fixed-time impulsive systems can be regarded as the comparison system of the variable-time impulsive neural networks. Furthermore, a series of sufficient criteria are derived to ensure the existence and global exponential stability of periodic solution of variable-time impulsive neural networks, and to illustrate the same stability properties between variable-time impulsive neural networks and the fixed-time ones. The new criteria are established by applying Schaefer's fixed point theorem combined with the use of inequality technique. Finally, a numerical example is presented to show the effectiveness of the proposed results. Copyright © 2017 Elsevier Ltd. All rights reserved.
Kandala, Sridhar; Nolan, Dan; Laumann, Timothy O.; Power, Jonathan D.; Adeyemo, Babatunde; Harms, Michael P.; Petersen, Steven E.; Barch, Deanna M.
2016-01-01
Abstract Like all resting-state functional connectivity data, the data from the Human Connectome Project (HCP) are adversely affected by structured noise artifacts arising from head motion and physiological processes. Functional connectivity estimates (Pearson's correlation coefficients) were inflated for high-motion time points and for high-motion participants. This inflation occurred across the brain, suggesting the presence of globally distributed artifacts. The degree of inflation was further increased for connections between nearby regions compared with distant regions, suggesting the presence of distance-dependent spatially specific artifacts. We evaluated several denoising methods: censoring high-motion time points, motion regression, the FMRIB independent component analysis-based X-noiseifier (FIX), and mean grayordinate time series regression (MGTR; as a proxy for global signal regression). The results suggest that FIX denoising reduced both types of artifacts, but left substantial global artifacts behind. MGTR significantly reduced global artifacts, but left substantial spatially specific artifacts behind. Censoring high-motion time points resulted in a small reduction of distance-dependent and global artifacts, eliminating neither type. All denoising strategies left differences between high- and low-motion participants, but only MGTR substantially reduced those differences. Ultimately, functional connectivity estimates from HCP data showed spatially specific and globally distributed artifacts, and the most effective approach to address both types of motion-correlated artifacts was a combination of FIX and MGTR. PMID:27571276
Guided self-assembly of magnetic beads for biomedical applications
NASA Astrophysics Data System (ADS)
Gusenbauer, Markus; Nguyen, Ha; Reichel, Franz; Exl, Lukas; Bance, Simon; Fischbacher, Johann; Özelt, Harald; Kovacs, Alexander; Brandl, Martin; Schrefl, Thomas
2014-02-01
Micromagnetic beads are widely used in biomedical applications for cell separation, drug delivery, and hyperthermia cancer treatment. Here we propose to use self-organized magnetic bead structures which accumulate on fixed magnetic seeding points to isolate circulating tumor cells. The analysis of circulating tumor cells is an emerging tool for cancer biology research and clinical cancer management including the detection, diagnosis and monitoring of cancer. Microfluidic chips for isolating circulating tumor cells use either affinity, size or density capturing methods. We combine multiphysics simulation techniques to understand the microscopic behavior of magnetic beads interacting with soft magnetic accumulation points used in lab-on-chip technologies. Our proposed chip technology offers the possibility to combine affinity and size capturing with special antibody-coated bead arrangements using a magnetic gradient field created by Neodymium Iron Boron permanent magnets. The multiscale simulation environment combines magnetic field computation, fluid dynamics and discrete particle dynamics.
The use of combination therapies in the acute management of migraine.
Krymchantowski, Abouch Valenty
2006-09-01
Migraine is a highly prevalent neurological disorder with multiple peripheral and central mechanisms. Targeting a single mechanism for treating individual attacks as well as for performing the prophylaxis has been shown to be only partially effective. Recently, the role of combining agents for acute migraine treatment has gained attention and the combination of a triptan plus a non-steroidal anti-inflammatory drug (NSAID) has demonstrated better efficacy. This review focuses on the fundamentals of treating migraine attacks with two or more agents, and emphasizes the characteristics of the recently approved fixed combination sumatriptan-naproxen. A PubMed search using the terms "migraine", "treatment", "acute", "triptans", "non-steroidal anti-inflammatory drugs", "sumatriptan", "naproxen", and "combination" was used. In addition, abstracts presented in the major meetings of the American Headache and the International Headache Societies along with the American Academy of Neurology were also evaluated. Although most of the few studies encountered were not controlled, there is a clear trend for better efficacy in combining triptans with NSAID. Additionally, the results of two recent large and controlled studies using fixed combinations of sumatriptan (50 mg and 85 mg) with 500 mg naproxen sodium confirm the initial observations of the clear superiority of this combination over the use of each agent alone. The differences in the endpoints 24-hour pain-relief response as well as pain-free and pain-relief parameters at 2-hour time-point are the most noticeable efficacy measures. Tolerability was not different between studied drugs. Combining triptans with NSAID and other agents for the acute treatment of migraine suggests better outcome efficacy measures than the use of single agents. The fixed combination of sumatriptan and naproxen sodium offers improved 2-hour and 24-hour benefits over monotherapy with each one these options. Recently issued FDA approval for marketing the combination (sumatriptan 50 mg-naproxen 500 mg) emphasizes the usefulness and safety of this new treatment for migraine attacks.
Metallic and antiferromagnetic fixed points from gravity
NASA Astrophysics Data System (ADS)
Paul, Chandrima
2018-06-01
We consider SU(2) × U(1) gauge theory coupled to matter field in adjoints and study RG group flow. We constructed Callan-Symanzik equation and subsequent β functions and study the fixed points. We find there are two fixed points, showing metallic and antiferromagnetic behavior. We have shown that metallic phase develops an instability if certain parametric conditions are satisfied.
PCC Framework for Program-Generators
NASA Technical Reports Server (NTRS)
Kong, Soonho; Choi, Wontae; Yi, Kwangkeun
2009-01-01
In this paper, we propose a proof-carrying code framework for program-generators. The enabling technique is abstract parsing, a static string analysis technique, which is used as a component for generating and validating certificates. Our framework provides an efficient solution for certifying program-generators whose safety properties are expressed in terms of the grammar representing the generated program. The fixed-point solution of the analysis is generated and attached with the program-generator on the code producer side. The consumer receives the code with a fixed-point solution and validates that the received fixed point is indeed a fixed point of the received code. This validation can be done in a single pass.
Metal Carbon Eutectics to Extend the Use of the Fixed-Point Technique in Precision IR Thermometry
NASA Astrophysics Data System (ADS)
Battuello, M.; Girard, F.; Florio, M.
2008-06-01
The high-temperature extension of the fixed-point technique for primary calibration of precision infrared (IR) thermometers was investigated both through mathematical simulations and laboratory investigations. Simulations were performed with Co C (1,324°C) and Pd C (1, 492°C) eutectic fixed points, and a precision IR thermometer was calibrated from the In point (156.5985°C) up to the Co C point. Mathematical simulations suggested the possibility of directly deriving the transition temperature of the Co C and Pd C points by extrapolating the calibration derived from fixed-point measurements from In to the Cu point. Both temperatures, as a result of the low uncertainty associated with the In Cu calibration and the high number of fixed points involved in the calibration process, can be derived with an uncertainty of 0.11°C for Co C and 0.18°C for Pd C. A transition temperature of 1,324.3°C for Co C was determined from the experimental verification, a value higher than, but compatible with, the one proposed by the thermometry community for inclusion as a secondary reference point for ITS-90 dissemination, i.e., 1,324.0°C.
Mangum, B W
1983-07-01
In an investigation of the melting and freezing behavior of succinonitrile, the triple-point temperature was determined to be 58.0805 degrees C, with an estimated uncertainty of +/- 0.0015 degrees C relative to the International Practical Temperature Scale of 1968 (IPTS-68). The triple-point temperature of this material is evaluated as a temperature-fixed point, and some clinical laboratory applications of this fixed point are proposed. In conjunction with the gallium and ice points, the availability of succinonitrile permits thermistor thermometers to be calibrated accurately and easily on the IPTS-68.
Phased-array ultrasonic surface contour mapping system and method for solids hoppers and the like
Fasching, George E.; Smith, Jr., Nelson S.
1994-01-01
A real time ultrasonic surface contour mapping system is provided including a digitally controlled phased-array of transmitter/receiver (T/R) elements located in a fixed position above the surface to be mapped. The surface is divided into a predetermined number of pixels which are separately scanned by an arrangement of T/R elements by applying phase delayed signals thereto that produce ultrasonic tone bursts from each T/R that arrive at a point X in phase and at the same time relative to the leading edge of the tone burst pulse so that the acoustic energies from each T/R combine in a reinforcing manner at point X. The signals produced by the reception of the echo signals reflected from point X back to the T/Rs are also delayed appropriately so that they add in phase at the input of a signal combiner. This combined signal is then processed to determine the range to the point X using density-corrected sound velocity values. An autofocusing signal is developed from the computed average range for a complete scan of the surface pixels. A surface contour map is generated in real time form the range signals on a video monitor.
NASA Astrophysics Data System (ADS)
Zvizdic, Davor; Veliki, Tomislav; Grgec Bermanec, Lovorka
2008-06-01
This article describes the realization of the International Temperature Scale in the range from 234.3 K (mercury triple point) to 1084.62°C (copper freezing point) at the Laboratory for Process Measurement (LPM), Faculty of Mechanical Engineering and Naval Architecture (FSB), University of Zagreb. The system for the realization of the ITS-90 consists of the sealed fixed-point cells (mercury triple point, water triple point and gallium melting point) and the apparatus designed for the optimal realization of open fixed-point cells which include the gallium melting point, tin freezing point, zinc freezing point, aluminum freezing point, and copper freezing point. The maintenance of the open fixed-point cells is described, including the system for filling the cells with pure argon and for maintaining the pressure during the realization.
Aveyard, Paul; Wang, Dechao; Connock, Martin; Fry-Smith, Anne; Barton, Pelham; Moore, David
2009-05-01
A Society for Research on Nicotine and Tobacco working group recommended outcome measures for cessation-induction trials and aid-to-cessation trials. Cessation-induction trials aim to motivate unwilling quitters to make a quit attempt. Aid-to-cessation trials give either medication or behavioral interventions to increase the rate at which willing quitters succeed in their attempts. Nicotine-assisted reduction programs combine features of both types of interventions by giving nicotine replacement to unwilling quitters. Treatment can be prolonged more than a year, quit attempts can occur and succeed early or late in the program, and renewed quit attempts are an inherent part of the program. Conventional outcome measures are tied to a fixed but arbitrary point in follow-up and cannot capture the true outcome: Prolonged cessation anchored to the point at which a person makes a successful quit attempt. We propose that the outcome should be counted from the successful quit attempt that began during the treatment period and continues for a defined period, ideally 6 months. In particular, if a trial compared a short reduction program with a long reduction program, it would not be possible to obtain an unbiased assessment of the outcome of such a trial using a measure tied to a fixed point in follow-up. Floating prolonged abstinence could provide such an assessment and is suitable for either prolonged cessation-induction trial or combined cessation-induction and aid-to-cessation trials.
Exact results for the O( N ) model with quenched disorder
NASA Astrophysics Data System (ADS)
Delfino, Gesualdo; Lamsen, Noel
2018-04-01
We use scale invariant scattering theory to exactly determine the lines of renormalization group fixed points for O( N )-symmetric models with quenched disorder in two dimensions. Random fixed points are characterized by two disorder parameters: a modulus that vanishes when approaching the pure case, and a phase angle. The critical lines fall into three classes depending on the values of the disorder modulus. Besides the class corresponding to the pure case, a second class has maximal value of the disorder modulus and includes Nishimori-like multicritical points as well as zero temperature fixed points. The third class contains critical lines that interpolate, as N varies, between the first two classes. For positive N , it contains a single line of infrared fixed points spanning the values of N from √{2}-1 to 1. The symmetry sector of the energy density operator is superuniversal (i.e. N -independent) along this line. For N = 2 a line of fixed points exists only in the pure case, but accounts also for the Berezinskii-Kosterlitz-Thouless phase observed in presence of disorder.
NASA Astrophysics Data System (ADS)
Qiu, Mo; Yu, Simin; Wen, Yuqiong; Lü, Jinhu; He, Jianbin; Lin, Zhuosheng
In this paper, a novel design methodology and its FPGA hardware implementation for a universal chaotic signal generator is proposed via the Verilog HDL fixed-point algorithm and state machine control. According to continuous-time or discrete-time chaotic equations, a Verilog HDL fixed-point algorithm and its corresponding digital system are first designed. In the FPGA hardware platform, each operation step of Verilog HDL fixed-point algorithm is then controlled by a state machine. The generality of this method is that, for any given chaotic equation, it can be decomposed into four basic operation procedures, i.e. nonlinear function calculation, iterative sequence operation, iterative values right shifting and ceiling, and chaotic iterative sequences output, each of which corresponds to only a state via state machine control. Compared with the Verilog HDL floating-point algorithm, the Verilog HDL fixed-point algorithm can save the FPGA hardware resources and improve the operation efficiency. FPGA-based hardware experimental results validate the feasibility and reliability of the proposed approach.
Establishment of the Co-C Eutectic Fixed-Point Cell for Thermocouple Calibrations at NIMT
NASA Astrophysics Data System (ADS)
Ongrai, O.; Elliott, C. J.
2017-08-01
In 2015, NIMT first established a Co-C eutectic temperature reference (fixed-point) cell measurement capability for thermocouple calibration to support the requirements of Thailand's heavy industries and secondary laboratories. The Co-C eutectic fixed-point cell is a facility transferred from NPL, where the design was developed through European and UK national measurement system projects. In this paper, we describe the establishment of a Co-C eutectic fixed-point cell for thermocouple calibration at NIMT. This paper demonstrates achievement of the required furnace uniformity, the Co-C plateau realization and the comparison data between NIMT and NPL Co-C cells by using the same standard Pt/Pd thermocouple, demonstrating traceability. The NIMT measurement capability for noble metal type thermocouples at the new Co-C eutectic fixed point (1324.06°C) is estimated to be within ± 0.60 K (k=2). This meets the needs of Thailand's high-temperature thermocouple users—for which previously there has been no traceable calibration facility.
Fletcher, Jason M
2015-07-01
This paper provides some of the first evidence of peer effects in college enrollment decisions. There are several empirical challenges in assessing the influences of peers in this context, including the endogeneity of high school, shared group-level unobservables, and identifying policy-relevant parameters of social interactions models. This paper addresses these issues by using an instrumental variables/fixed effects approach that compares students in the same school but different grade-levels who are thus exposed to different sets of classmates. In particular, plausibly exogenous variation in peers' parents' college expectations are used as an instrument for peers' college choices. Preferred specifications indicate that increasing a student's exposure to college-going peers by ten percentage points is predicted to raise the student's probability of enrolling in college by 4 percentage points. This effect is roughly half the magnitude of growing up in a household with married parents (vs. an unmarried household). Copyright © 2015 Elsevier Inc. All rights reserved.
An hp symplectic pseudospectral method for nonlinear optimal control
NASA Astrophysics Data System (ADS)
Peng, Haijun; Wang, Xinwei; Li, Mingwu; Chen, Biaosong
2017-01-01
An adaptive symplectic pseudospectral method based on the dual variational principle is proposed and is successfully applied to solving nonlinear optimal control problems in this paper. The proposed method satisfies the first order necessary conditions of continuous optimal control problems, also the symplectic property of the original continuous Hamiltonian system is preserved. The original optimal control problem is transferred into a set of nonlinear equations which can be solved easily by Newton-Raphson iterations, and the Jacobian matrix is found to be sparse and symmetric. The proposed method, on one hand, exhibits exponent convergence rates when the number of collocation points are increasing with the fixed number of sub-intervals; on the other hand, exhibits linear convergence rates when the number of sub-intervals is increasing with the fixed number of collocation points. Furthermore, combining with the hp method based on the residual error of dynamic constraints, the proposed method can achieve given precisions in a few iterations. Five examples highlight the high precision and high computational efficiency of the proposed method.
Fletcher, Jason M.
2015-01-01
This paper provides some of the first evidence of peer effects in college enrollment decisions. There are several empirical challenges in assessing the influences of peers in this context, including the endogeneity of high school, shared group-level unobservables, and identifying policy-relevant parameters of social interactions models. This paper addresses these issues by using an instrumental variables/fixed effects approach that compares students in the same school but different grade-levels who are thus exposed to different sets of classmates. In particular, plausibly exogenous variation in peers’ parents’ college expectations are used as an instrument for peers’ college choices. Preferred specifications indicate that increasing a student’s exposure to college-going peers by ten percentage points is predicted to raise the student’s probability of enrolling in college by 4 percentage points. This effect is roughly half the magnitude of growing up in a household with married parents (vs. an unmarried household). PMID:26004476
Moving Force Identification: a Time Domain Method
NASA Astrophysics Data System (ADS)
Law, S. S.; Chan, T. H. T.; Zeng, Q. H.
1997-03-01
The solution for the vertical dynamic interaction forces between a moving vehicle and the bridge deck is analytically derived and experimentally verified. The deck is modelled as a simply supported beam with viscous damping, and the vehicle/bridge interaction force is modelled as one-point or two-point loads with fixed axle spacing, moving at constant speed. The method is based on modal superposition and is developed to identify the forces in the time domain. Both cases of one-point and two-point forces moving on a simply supported beam are simulated. Results of laboratory tests on the identification of the vehicle/bridge interaction forces are presented. Computation simulations and laboratory tests show that the method is effective, and acceptable results can be obtained by combining the use of bending moment and acceleration measurements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Common Carrier Fixed Point-to-Point Microwave Service § 101.701 Eligibility. (a) Authorizations... the customers (or points of service) on the microwave system involved, including those served through...
Code of Federal Regulations, 2011 CFR
2011-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Common Carrier Fixed Point-to-Point Microwave Service § 101.701 Eligibility. (a) Authorizations... the customers (or points of service) on the microwave system involved, including those served through...
Code of Federal Regulations, 2013 CFR
2013-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Common Carrier Fixed Point-to-Point Microwave Service § 101.701 Eligibility. (a) Authorizations... the customers (or points of service) on the microwave system involved, including those served through...
Code of Federal Regulations, 2012 CFR
2012-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Common Carrier Fixed Point-to-Point Microwave Service § 101.701 Eligibility. (a) Authorizations... the customers (or points of service) on the microwave system involved, including those served through...
Stability analysis of an autocatalytic protein model
NASA Astrophysics Data System (ADS)
Lee, Julian
2016-05-01
A self-regulatory genetic circuit, where a protein acts as a positive regulator of its own production, is known to be the simplest biological network with a positive feedback loop. Although at least three components—DNA, RNA, and the protein—are required to form such a circuit, stability analysis of the fixed points of this self-regulatory circuit has been performed only after reducing the system to a two-component system, either by assuming a fast equilibration of the DNA component or by removing the RNA component. Here, stability of the fixed points of the three-component positive feedback loop is analyzed by obtaining eigenvalues of the full three-dimensional Hessian matrix. In addition to rigorously identifying the stable fixed points and saddle points, detailed information about the system can be obtained, such as the existence of complex eigenvalues near a fixed point.
Fixed-point theorems for families of weakly non-expansive maps
NASA Astrophysics Data System (ADS)
Mai, Jie-Hua; Liu, Xin-He
2007-10-01
In this paper, we present some fixed-point theorems for families of weakly non-expansive maps under some relatively weaker and more general conditions. Our results generalize and improve several results due to Jungck [G. Jungck, Fixed points via a generalized local commutativity, Int. J. Math. Math. Sci. 25 (8) (2001) 497-507], Jachymski [J. Jachymski, A generalization of the theorem by Rhoades and Watson for contractive type mappings, Math. Japon. 38 (6) (1993) 1095-1102], Guo [C. Guo, An extension of fixed point theorem of Krasnoselski, Chinese J. Math. (P.O.C.) 21 (1) (1993) 13-20], Rhoades [B.E. Rhoades, A comparison of various definitions of contractive mappings, Trans. Amer. Math. Soc. 226 (1977) 257-290], and others.
Common Coupled Fixed Point Theorems for Two Hybrid Pairs of Mappings under φ-ψ Contraction
Handa, Amrish
2014-01-01
We introduce the concept of (EA) property and occasional w-compatibility for hybrid pair F : X × X → 2X and f : X → X. We also introduce common (EA) property for two hybrid pairs F, G : X → 2X and f, g : X → X. We establish some common coupled fixed point theorems for two hybrid pairs of mappings under φ-ψ contraction on noncomplete metric spaces. An example is also given to validate our results. We improve, extend and generalize several known results. The results of this paper generalize the common fixed point theorems for hybrid pairs of mappings and essentially contain fixed point theorems for hybrid pair of mappings. PMID:27340688
Trivial dynamics in discrete-time systems: carrying simplex and translation arcs
NASA Astrophysics Data System (ADS)
Niu, Lei; Ruiz-Herrera, Alfonso
2018-06-01
In this paper we show that the dynamical behavior in (first octant) of the classical Kolmogorov systems of competitive type admitting a carrying simplex can be sometimes determined completely by the number of fixed points on the boundary and the local behavior around them. Roughly speaking, T has trivial dynamics (i.e. the omega limit set of any orbit is a connected set contained in the set of fixed points) provided T has exactly four hyperbolic nontrivial fixed points in with local attractors on the carrying simplex and local repellers on the carrying simplex; and there exists a unique hyperbolic fixed point in Int. Our results are applied to some classical models including the Leslie–Gower models, Atkinson-Allen systems and Ricker maps.
Nickel-Silver Monotectic in Alumina Crucible for Use with Contact Thermometry
NASA Astrophysics Data System (ADS)
Gotoh, M.; Dedyulin, S. N.
2017-07-01
Previously, the authors have published work describing a pure Ni fixed point within alumina crucibles. The success of this study stimulated working with the Ni-Ag monotectic point in alumina crucibles. Similar to eutectic points, the Ni-Ag monotectic temperature is an invariant point but it differs from a eutectic reaction in such a way that the monotectic phase change takes place from Ni-Ag liquid solution to Ni-Ag solid solution and Ag rich Ni-Ag liquid solution. In the phase diagram references, the Ni-Ag monotectic phase transition temperature is assigned to be about 20°C below the pure Ni melting/freezing point. As is the case for pure Ni, mechanical stability is one of the concerns. Therefore, proper cell design is necessary to avoid breakage of the alumina crucible. The techniques used for the fabrication and measurement of the pure Ni cell were applied to the Ni-Ag cell as well. The cells have been successfully fabricated and the temperature measurement at the fixed point was carried out for more than 20 thermal cycles in total. A Pt/Pd thermocouple was used to measure the temperature and was calibrated from the tin point to the gold point to measure the ITS-90. Freezing plateaus are realized with the technique of "recurrent offset freezing method with reserved solid". The duration of each freezing plateau is a minimum of 30 min. The monotectic transformation temperature for the best performed cell is determined as 1428.27°C with a combined uncertainty of ±0.06°C ({k}=1).
47 CFR 101.101 - Frequency availability.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE... Television Relay Service—(Part 78) CC: Common Carrier Fixed Point-to-Point Microwave Service—(Part 101...-Point Microwave Service—(Part 101, Subparts C & H) PCS: Personal Communications Service—(Part 24) PET...
Gérikas Ribeiro, Catherine; Lopes Dos Santos, Adriana; Marie, Dominique; Pereira Brandini, Frederico; Vaulot, Daniel
2018-05-01
Symbioses between eukaryotic algae and nitrogen-fixing cyanobacteria have been recognized in recent years as a key source of new nitrogen in the oceans. We investigated the composition of the small photosynthetic eukaryote communities associated with nitrogen-fixing cyanobacteria in the Brazilian South Atlantic Bight using a combination of flow cytometry sorting and high throughput sequencing of two genes: the V4 region of 18S rRNA and nifH. Two distinct eukaryotic communities were often encountered, one dominated by the Mamiellophyceae Bathycoccus and Ostreococcus, and one dominated by a prymnesiophyte known to live in symbiosis with the UCYN-A1 nitrogen-fixing cyanobacterium. Among nifH sequences, those from UCYN-A1 were most abundant but three other UCYN-A clades (A2, A3, A4) were also found. Network analysis confirmed the relation between A1 and A2 clades and their hypothesized hosts and pointed out to the potential association between novel clade A4 with Braarudosphaera bigelowii, previously hypothesized to host A2.
21 CFR 300.50 - Fixed-combination prescription drugs for humans.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 5 2011-04-01 2011-04-01 false Fixed-combination prescription drugs for humans. 300.50 Section 300.50 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE GENERAL Combination Drugs § 300.50 Fixed-combination prescription...
21 CFR 300.50 - Fixed-combination prescription drugs for humans.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 5 2013-04-01 2013-04-01 false Fixed-combination prescription drugs for humans. 300.50 Section 300.50 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE GENERAL Combination Drugs § 300.50 Fixed-combination prescription...
21 CFR 300.50 - Fixed-combination prescription drugs for humans.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Fixed-combination prescription drugs for humans. 300.50 Section 300.50 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE GENERAL Combination Drugs § 300.50 Fixed-combination prescription...
21 CFR 300.50 - Fixed-combination prescription drugs for humans.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 5 2014-04-01 2014-04-01 false Fixed-combination prescription drugs for humans. 300.50 Section 300.50 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE GENERAL Combination Drugs § 300.50 Fixed-combination prescription...
21 CFR 300.50 - Fixed-combination prescription drugs for humans.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 5 2012-04-01 2012-04-01 false Fixed-combination prescription drugs for humans. 300.50 Section 300.50 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR HUMAN USE GENERAL Combination Drugs § 300.50 Fixed-combination prescription...
Linear Power-Flow Models in Multiphase Distribution Networks: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bernstein, Andrey; Dall'Anese, Emiliano
This paper considers multiphase unbalanced distribution systems and develops approximate power-flow models where bus-voltages, line-currents, and powers at the point of common coupling are linearly related to the nodal net power injections. The linearization approach is grounded on a fixed-point interpretation of the AC power-flow equations, and it is applicable to distribution systems featuring (i) wye connections; (ii) ungrounded delta connections; (iii) a combination of wye-connected and delta-connected sources/loads; and, (iv) a combination of line-to-line and line-to-grounded-neutral devices at the secondary of distribution transformers. The proposed linear models can facilitate the development of computationally-affordable optimization and control applications -- frommore » advanced distribution management systems settings to online and distributed optimization routines. Performance of the proposed models is evaluated on different test feeders.« less
47 CFR 101.107 - Frequency tolerance.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE...-point microwave and stations providing MVDDS. 5 For private operational fixed point-to-point microwave... noted in the table of paragraph (a) of this section. (b) Heterodyne microwave radio systems may be...
47 CFR 101.107 - Frequency tolerance.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE...-point microwave and stations providing MVDDS. 5 For private operational fixed point-to-point microwave... noted in the table of paragraph (a) of this section. (b) Heterodyne microwave radio systems may be...
47 CFR 101.107 - Frequency tolerance.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE...-point microwave and stations providing MVDDS. 5 For private operational fixed point-to-point microwave... noted in the table of paragraph (a) of this section. (b) Heterodyne microwave radio systems may be...
Vinnakota, Narayana R; Krishna, V; Viswanath, V; Ahmed, Zaheer; Shaik, Kamal S; Boppana, Naveen K
2016-12-01
To assess the knowledge, attitude, and practices of fixed dose combination drugs among postgraduate dental students. A cross-sectional study was carried out among postgraduate dental students of dental colleges in coastal Andhra Pradesh. Three colleges were randomly selected and students of all the three years were included. Data was collected from the specialities of oral medicine and radiology, oral surgery, endodontics, pedodontics, periodontics, and public health dentistry. The total sample was 90 postgraduate students; informed consent was obtained from the participants, and a pretested questionnaire was distributed to them. Data was analyzed using the Statistical Package for the Social Sciences version 20 software. Out of 90 postgraduates, 33 were males and 57 were females. Thirty-five percent were aware of the essential medical list (EML), among them 11% were from oral medicine and radiology and 6.7% were from pedodontics. However, most of them were unaware of the number of fixed dose combination drugs present in the World Health Organization EML. None of them were able to name at least a single banned fixed dose combination drug. Most of them were unaware of the advantages and disadvantages of using fixed dose combination drugs. Amoxicillin with clavulanic acid was the most common drug prescribed by students (73.3%) followed by ofloxacin with ornidazole (54.4%), ibuprofen with paracetamol (53.3%), and sulfamethoxazole with trimethoprim (6%). Most of them were unaware of the rationality in using fixed dose combination drugs. Common sources of information were medical representatives 43 (47.8%), internet 39 (43.3%), and 12 (13.3%) reported using WHO EML. There is an urgent need to improve knowledge on the rationality for using fixed dose combination, EML, and banned fixed dose combination in India to the promote rational use of fixed dose combination.
NASA Astrophysics Data System (ADS)
Nezir, Veysel; Mustafa, Nizami
2017-04-01
In 2008, P.K. Lin provided the first example of a nonreflexive space that can be renormed to have fixed point property for nonexpansive mappings. This space was the Banach space of absolutely summable sequences l1 and researchers aim to generalize this to c0, Banach space of null sequences. Before P.K. Lin's intriguing result, in 1979, Goebel and Kuczumow showed that there is a large class of non-weak* compact closed, bounded, convex subsets of l1 with fixed point property for nonexpansive mappings. Then, P.K. Lin inspired by Goebel and Kuczumow's ideas to give his result. Similarly to P.K. Lin's study, Hernández-Linares worked on L1 and in his Ph.D. thesis, supervisored under Maria Japón, showed that L1 can be renormed to have fixed point property for affine nonexpansive mappings. Then, related questions for c0 have been considered by researchers. Recently, Nezir constructed several equivalent norms on c0 and showed that there are non-weakly compact closed, bounded, convex subsets of c0 with fixed point property for affine nonexpansive mappings. In this study, we construct a family of equivalent norms containing those developed by Nezir as well and show that there exists a large class of non-weakly compact closed, bounded, convex subsets of c0 with fixed point property for affine nonexpansive mappings.
Analyzing survival curves at a fixed point in time for paired and clustered right-censored data
Su, Pei-Fang; Chi, Yunchan; Lee, Chun-Yi; Shyr, Yu; Liao, Yi-De
2018-01-01
In clinical trials, information about certain time points may be of interest in making decisions about treatment effectiveness. Rather than comparing entire survival curves, researchers can focus on the comparison at fixed time points that may have a clinical utility for patients. For two independent samples of right-censored data, Klein et al. (2007) compared survival probabilities at a fixed time point by studying a number of tests based on some transformations of the Kaplan-Meier estimators of the survival function. However, to compare the survival probabilities at a fixed time point for paired right-censored data or clustered right-censored data, their approach would need to be modified. In this paper, we extend the statistics to accommodate the possible within-paired correlation and within-clustered correlation, respectively. We use simulation studies to present comparative results. Finally, we illustrate the implementation of these methods using two real data sets. PMID:29456280
APMP Scale Comparison with Three Radiation Thermometers and Six Fixed-Point Blackbodies
NASA Astrophysics Data System (ADS)
Yamada, Y.; Shimizu, Y.; Ishii, J.
2015-08-01
New Asia Pacific Metrology Programme (APMP) comparisons of radiation thermometry standards, APMP TS-11, and -12, have recently been initiated. These new APMP comparisons cover the temperature range from to . Three radiation thermometers with central wavelengths of 1.6 , 0.9 , and 0.65 are the transfer devices for the radiation thermometer scale comparison conducted in the so-called star configuration. In parallel, a compact fixed-point blackbody furnace that houses six types of fixed-point cells of In, Sn, Zn, Al, Ag, and Cu is circulated, again in a star-type comparison, to substantiate fixed-point calibration capabilities. Twelve APMP national metrology institutes are taking part in this endeavor, in which the National Metrology Institute of Japan acts as the pilot. In this article, the comparison scheme is described with emphasis on the features of the transfer devices, i.e., the radiation thermometers and the fixed-point blackbodies. Results of preliminary evaluations of the performance and characteristic of these instruments as well as the evaluation method of the comparison results are presented.
Long-Term Stability of WC-C Peritectic Fixed Point
NASA Astrophysics Data System (ADS)
Khlevnoy, B. B.; Grigoryeva, I. A.
2015-03-01
The tungsten carbide-carbon peritectic (WC-C) melting transition is an attractive high-temperature fixed point with a temperature of . Earlier investigations showed high repeatability, small melting range, low sensitivity to impurities, and robustness of WC-C that makes it a prospective candidate for the highest fixed point of the temperature scale. This paper presents further study of the fixed point, namely the investigation of the long-term stability of the WC-C melting temperature. For this purpose, a new WC-C cell of the blackbody type was built using tungsten powder of 99.999 % purity. The stability of the cell was investigated during the cell aging for 50 h at the cell working temperature that tooks 140 melting/freezing cycles. The method of investigation was based on the comparison of the WC-C tested cell with a reference Re-C fixed-point cell that reduces an influence of the probable instability of a radiation thermometer. It was shown that after the aging period, the deviation of the WC-C cell melting temperature was with an uncertainty of.
Renormalization group fixed points of foliated gravity-matter systems
NASA Astrophysics Data System (ADS)
Biemans, Jorn; Platania, Alessia; Saueressig, Frank
2017-05-01
We employ the Arnowitt-Deser-Misner formalism to study the renormalization group flow of gravity minimally coupled to an arbitrary number of scalar, vector, and Dirac fields. The decomposition of the gravitational degrees of freedom into a lapse function, shift vector, and spatial metric equips spacetime with a preferred (Euclidean) "time"- direction. In this work, we provide a detailed derivation of the renormalization group flow of Newton's constant and the cosmological constant on a flat Friedmann-Robertson-Walker background. Adding matter fields, it is shown that their contribution to the flow is the same as in the covariant formulation and can be captured by two parameters d g d λ . We classify the resulting fixed point structure as a function of these parameters finding that the existence of non-Gaussian renormalization group fixed points is rather generic. In particular the matter content of the standard model and its most common extensions gives rise to one non-Gaussian fixed point with real critical exponents suitable for Asymptotic Safety. Moreover, we find non-Gaussian fixed points for any number of scalar matter fields, making the scenario attractive for cosmological model building.
NASA Technical Reports Server (NTRS)
Holms, A. G.
1980-01-01
Population model coefficients were chosen to simulate a saturated 2 to the fourth power fixed effects experiment having an unfavorable distribution of relative values. Using random number studies, deletion strategies were compared that were based on the F distribution, on an order statistics distribution of Cochran's, and on a combination of the two. Results of the comparisons and a recommended strategy are given.
Further results on global state feedback stabilization of nonlinear high-order feedforward systems.
Xie, Xue-Jun; Zhang, Xing-Hui
2014-03-01
In this paper, by introducing a combined method of sign function, homogeneous domination and adding a power integrator, and overcoming several troublesome obstacles in the design and analysis, the problem of state feedback control for a class of nonlinear high-order feedforward systems with the nonlinearity's order being relaxed to an interval rather than a fixed point is solved. Copyright © 2013 ISA. Published by Elsevier Ltd. All rights reserved.
47 CFR 101.133 - Limitations on use of transmitters.
Code of Federal Regulations, 2011 CFR
2011-10-01
... SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.133 Limitations on use of transmitters. (a...) Private operational fixed point-to-point microwave stations authorized in this service may communicate...-point microwave licenses may use the same transmitting equipment under the following terms and...
47 CFR 101.133 - Limitations on use of transmitters.
Code of Federal Regulations, 2013 CFR
2013-10-01
... SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.133 Limitations on use of transmitters. (a...) Private operational fixed point-to-point microwave stations authorized in this service may communicate...-point microwave licenses may use the same transmitting equipment under the following terms and...
47 CFR 101.133 - Limitations on use of transmitters.
Code of Federal Regulations, 2014 CFR
2014-10-01
... SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.133 Limitations on use of transmitters. (a...) Private operational fixed point-to-point microwave stations authorized in this service may communicate...-point microwave licenses may use the same transmitting equipment under the following terms and...
47 CFR 101.133 - Limitations on use of transmitters.
Code of Federal Regulations, 2012 CFR
2012-10-01
... SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.133 Limitations on use of transmitters. (a...) Private operational fixed point-to-point microwave stations authorized in this service may communicate...-point microwave licenses may use the same transmitting equipment under the following terms and...
47 CFR 101.133 - Limitations on use of transmitters.
Code of Federal Regulations, 2010 CFR
2010-10-01
... SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.133 Limitations on use of transmitters. (a...) Private operational fixed point-to-point microwave stations authorized in this service may communicate...-point microwave licenses may use the same transmitting equipment under the following terms and...
Anderson Acceleration for Fixed-Point Iterations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, Homer F.
The purpose of this grant was to support research on acceleration methods for fixed-point iterations, with applications to computational frameworks and simulation problems that are of interest to DOE.
Side Effects in Time Discounting Procedures: Fixed Alternatives Become the Reference Point
2016-01-01
Typical research on intertemporal choice utilizes a two-alternative forced choice (2AFC) paradigm requiring participants to choose between a smaller sooner and larger later payoff. In the adjusting-amount procedure (AAP) one of the alternatives is fixed and the other is adjusted according to particular choices made by the participant. Such a method makes the alternatives unequal in status and is speculated to make the fixed alternative a reference point for choices, thereby affecting the decision made. The current study shows that fixing different alternatives in the AAP influences discount rates in intertemporal choices. Specifically, individuals’ (N = 283) choices were affected to just the same extent by merely fixing an alternative as when choices were preceded by scenarios explicitly imposing reference points. PMID:27768759
Picon, Paulo Dornelles; Costa, Marisa Boff; da Veiga Picon, Rafael; Fendt, Lucia Costa Cabral; Suksteris, Maurício Leichter; Saccilotto, Indara Carmanim; Dornelles, Alicia Dorneles; Schmidt, Luis Felipe Carissimi
2013-11-22
The common cold and other viral airway infections are highly prevalent in the population, and their treatment often requires the use of medications for symptomatic relief. Paracetamol is as an analgesic and antipyretic; chlorphenamine is an antihistamine; and phenylephrine, a vasoconstrictor and decongestant. This randomized, double-blind, placebo-controlled trial sought to evaluate the efficacy and safety of a fixed-dose combination of paracetamol, chlorphenamine and phenylephrine in the symptomatic treatment of the common cold and flu-like syndrome in adults. This study enrolled 146 individuals aged 18 to 60 years who had moderate to severe flu-like syndrome or common cold. After clinical examination and laboratory tests, individuals were randomly assigned to receive the fixed-dose combination (73) or placebo (73), five capsules per day for 48 to 72 hours. The primary efficacy endpoint was the sum of the scores of 10 symptoms on a four-point Likert-type scale. To evaluate treatment safety, the occurrence of adverse events was also measured. Mean age was 33.5 (±9.5) years in the placebo group and 33.8 (±11.5) in the treatment group. There were 55 women and 18 men in the placebo group, and 46 women and 27 men in the treatment group. Comparison of overall symptom scores in the two groups revealed a significantly greater reduction in the treatment group than in the placebo group (p = 0.015). Analysis at the first 13 dose intervals (± 66 h of treatment) showed a greater reduction of symptom scores in the treatment group than in the placebo group (p < 0.05). The number and distribution of adverse events were similar in both groups. A fixed-dose combination of paracetamol, chlorphenamine and phenylephrine was safe and more effective than placebo in the symptomatic treatment of the common cold or flu-like syndrome in adults. NCT01389518.
2013-01-01
Background The common cold and other viral airway infections are highly prevalent in the population, and their treatment often requires the use of medications for symptomatic relief. Paracetamol is as an analgesic and antipyretic; chlorphenamine is an antihistamine; and phenylephrine, a vasoconstrictor and decongestant. This randomized, double-blind, placebo-controlled trial sought to evaluate the efficacy and safety of a fixed-dose combination of paracetamol, chlorphenamine and phenylephrine in the symptomatic treatment of the common cold and flu-like syndrome in adults. Methods This study enrolled 146 individuals aged 18 to 60 years who had moderate to severe flu-like syndrome or common cold. After clinical examination and laboratory tests, individuals were randomly assigned to receive the fixed-dose combination (73) or placebo (73), five capsules per day for 48 to 72 hours. The primary efficacy endpoint was the sum of the scores of 10 symptoms on a four-point Likert-type scale. To evaluate treatment safety, the occurrence of adverse events was also measured. Results Mean age was 33.5 (±9.5) years in the placebo group and 33.8 (±11.5) in the treatment group. There were 55 women and 18 men in the placebo group, and 46 women and 27 men in the treatment group. Comparison of overall symptom scores in the two groups revealed a significantly greater reduction in the treatment group than in the placebo group (p = 0.015). Analysis at the first 13 dose intervals (± 66 h of treatment) showed a greater reduction of symptom scores in the treatment group than in the placebo group (p < 0.05). The number and distribution of adverse events were similar in both groups. Conclusion A fixed-dose combination of paracetamol, chlorphenamine and phenylephrine was safe and more effective than placebo in the symptomatic treatment of the common cold or flu-like syndrome in adults. Trial registration NCT01389518 PMID:24261438
Cushman, William C; Bakris, George L; White, William B; Weber, Michael A; Sica, Domenic; Roberts, Andrew; Lloyd, Eric; Kupfer, Stuart
2012-08-01
Azilsartan medoxomil, an effective, long-acting angiotensin II receptor blocker, is a new treatment for hypertension that is also being developed in fixed-dose combinations with chlorthalidone, a potent, long-acting thiazide-like diuretic. We compared once-daily fixed-dose combinations of azilsartan medoxomil/chlorthalidone force titrated to a high dose of either 40/25 mg or 80/25 mg with a fixed-dose combination of the angiotensin II receptor blocker olmesartan medoxomil plus the thiazide diuretic hydrochlorothiazide force titrated to 40/25 mg. The design was a randomized, 3-arm, double-blind, 12-week study of 1071 participants with baseline clinic systolic blood pressure 160 to 190 mm Hg and diastolic blood pressure ≤119 mm Hg. Patients had a mean age of 57 years; 59% were men, 73% were white, and 22% were black. At baseline, mean clinic blood pressure was 165/96 mm Hg and 24-hour mean blood pressure was 150/88 mm Hg. Changes in clinic (primary end point) and ambulatory systolic blood pressures at week 12 were significantly greater in both azilsartan medoxomil/chlorthalidone arms than in the olmesartan/hydrochlorothiazide arm (P<0.001). Changes in clinic systolic blood pressure (mean±SE) were -42.5±0.8, -44.0±0.8, and -37.1±0.8 mm Hg, respectively. Changes in 24-hour ambulatory systolic blood pressure were -33.9±0.8, -36.3±0.8, and -27.5±0.8 mm Hg, respectively. Adverse events leading to permanent drug discontinuation occurred in 7.9%, 14.5%, and 7.1% of the groups given azilsartan medoxomil/chlorthalidone 40/25 mg, azilsartan medoxomil/chlorthalidone 80/25 mg, and olmesartan/hydrochlorothiazide 40/25 mg, respectively. This large, forced-titration study has demonstrated superior antihypertensive efficacy of azilsartan medoxomil/chlorthalidone fixed-dose combinations compared with the maximum approved dose of olmesartan/hydrochlorothiazide.
Li, Xia; Guo, Meifang; Su, Yongfu
2016-01-01
In this article, a new multidirectional monotone hybrid iteration algorithm for finding a solution to the split common fixed point problem is presented for two countable families of quasi-nonexpansive mappings in Banach spaces. Strong convergence theorems are proved. The application of the result is to consider the split common null point problem of maximal monotone operators in Banach spaces. Strong convergence theorems for finding a solution of the split common null point problem are derived. This iteration algorithm can accelerate the convergence speed of iterative sequence. The results of this paper improve and extend the recent results of Takahashi and Yao (Fixed Point Theory Appl 2015:87, 2015) and many others .
Fixed-Rate Compressed Floating-Point Arrays.
Lindstrom, Peter
2014-12-01
Current compression schemes for floating-point data commonly take fixed-precision values and compress them to a variable-length bit stream, complicating memory management and random access. We present a fixed-rate, near-lossless compression scheme that maps small blocks of 4(d) values in d dimensions to a fixed, user-specified number of bits per block, thereby allowing read and write random access to compressed floating-point data at block granularity. Our approach is inspired by fixed-rate texture compression methods widely adopted in graphics hardware, but has been tailored to the high dynamic range and precision demands of scientific applications. Our compressor is based on a new, lifted, orthogonal block transform and embedded coding, allowing each per-block bit stream to be truncated at any point if desired, thus facilitating bit rate selection using a single compression scheme. To avoid compression or decompression upon every data access, we employ a software write-back cache of uncompressed blocks. Our compressor has been designed with computational simplicity and speed in mind to allow for the possibility of a hardware implementation, and uses only a small number of fixed-point arithmetic operations per compressed value. We demonstrate the viability and benefits of lossy compression in several applications, including visualization, quantitative data analysis, and numerical simulation.
NASA Astrophysics Data System (ADS)
Konks, V. Ia.
1981-05-01
Barrar's (1961) method for the analysis of the motion of a satellite of an oblate planet is extended to the case of hyperbolic motion. An analysis is presented of the motion of a material point in the gravitational field of a fixed center, combined with a gravitational dipole located at the point of inertia of a dynamically symmetric planet. Formulas are obtained for the hyperbolic motion of a spacecraft in the gravitational field of a spheroidal planet with an accuracy up to the second zonal harmonic of the expansion of its potential into a Legendre polynomial series in spherical coordinates.
Infrared fixed point of SU(2) gauge theory with six flavors
NASA Astrophysics Data System (ADS)
Leino, Viljami; Rummukainen, Kari; Suorsa, Joni; Tuominen, Kimmo; Tähtinen, Sara
2018-06-01
We compute the running of the coupling in SU(2) gauge theory with six fermions in the fundamental representation of the gauge group. We find strong evidence that this theory has an infrared stable fixed point at strong coupling and measure also the anomalous dimension of the fermion mass operator at the fixed point. This theory therefore likely lies close to the boundary of the conformal window and will display novel infrared dynamics if coupled with the electroweak sector of the Standard Model.
A dynamical system approach to Bianchi III cosmology for Hu-Sawicki type f( R) gravity
NASA Astrophysics Data System (ADS)
Banik, Sebika Kangsha; Banik, Debika Kangsha; Bhuyan, Kalyan
2018-02-01
The cosmological dynamics of spatially homogeneous but anisotropic Bianchi type-III space-time is investigated in presence of a perfect fluid within the framework of Hu-Sawicki model. We use the dynamical system approach to perform a detailed analysis of the cosmological behaviour of this model for the model parameters n=1, c_1=1, determining all the fixed points, their stability and corresponding cosmological evolution. We have found stable fixed points with de Sitter solution along with unstable radiation like fixed points. We have identified a matter like point which act like an unstable spiral and when the initial conditions of a trajectory are very close to this point, it stabilizes at a stable accelerating point. Thus, in this model, the universe can naturally approach to a phase of accelerated expansion following a radiation or a matter dominated phase. It is also found that the isotropisation of this model is affected by the spatial curvature and that all the isotropic fixed points are found to be spatially flat.
Study on the fixed point in crustal deformation before strong earthquake
NASA Astrophysics Data System (ADS)
Niu, A.; Li, Y.; Yan, W. Mr
2017-12-01
Usually, scholars believe that the fault pre-sliding or expansion phenomenon will be observed near epicenter area before strong earthquake, but more and more observations show that the crust deformation nearby epicenter area is smallest(Zhou, 1997; Niu,2009,2012;Bilham, 2005; Amoruso et al., 2010). The theory of Fixed point t is a branch of mathematics that arises from the theory of topological transformation and has important applications in obvious model analysis. An important precursory was observed by two tilt-meter sets, installed at Wenchuan Observatory in the epicenter area, that the tilt changes were the smallest compared with the other 8 stations around them in one year before the Wenchuan earthquake. To subscribe the phenomenon, we proposed the minimum annual variation range that used as a topological transformation. The window length is 1 year, and the sliding length is 1 day. The convergence of points with minimum annual change in the 3 years before the Wenchuan earthquake is studied. And the results show that the points with minimum deformation amplitude basically converge to the epicenter region before the earthquake. The possible mechanism of fixed point of crustal deformation was explored. Concerning the fixed point of crust deformation, the liquidity of lithospheric medium and the isostasy theory are accepted by many scholars (Bott &Dean, 1973; Merer et al.1988; Molnar et al., 1975,1978; Tapponnier et al., 1976; Wang et al., 2001). To explain the fixed point of crust deformation before earthquakes, we study the plate bending model (Bai, et al., 2003). According to plate bending model and real deformation data, we have found that the earthquake rupture occurred around the extreme point of plate bending, where the velocities of displacement, tilt, strain, gravity and so on are close to zero, and the fixed points are located around the epicenter.The phenomenon of fixed point of crust deformation is different from former understandings about the earthquake rupture precursor. 1) The observations for crust deformation in natural conditions are different with dry and static experiments, and the former had the meaning of stress wave.2)The earthquake rupture has a special triggering mechanism that is different from the experiment with limited scale rock fracture.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, J.; Zhang, J. T.; Ping, Q.
2013-09-11
The temperature primary standard over the range from the melting point of gallium to the freezing point of silver in National institute of Metrology (NIM), China, was established in the early 1990s. The performance of all of fixed-point furnaces degraded and needs to be updated due to many years of use. Nowadays, the satisfactory fixed point materials can be available with the development of the modern purification techniques. NIM plans to use a group of three cells for each defining fixed point temperature. In this way the eventual drift of individual cells can be evidenced by periodic intercomparison and thismore » will increase the reliability in disseminating the ITS-90 in China. This article describes the recent improvements in realization of ITS-90 over temperature range from the melting point of gallium to the freezing point of silver at NIM. Taking advantages of the technological advances in the design and manufacture of furnaces, the new three-zone furnaces and the open-type fixed points were developed from the freezing point of indium to the freezing point of silver, and a furnace with the three-zone semiconductor cooling was designed to automatically realize the melting point of gallium. The reproducibility of the new melting point of gallium and the new open-type freezing points of In, Sn, Zn. Al and Ag is improved, especially the freezing points of Al and Ag with the reproducibility of 0.2mK and 0.5mK respectively. The expanded uncertainty in the realization of these defining fixed point temperatures is 0.34mK, 0.44mK, 0.54mK, 0.60mK, 1.30mK and 1.88mK respectively.« less
Li, Bingyi; Chen, Liang; Wei, Chunpeng; Xie, Yizhuang; Chen, He; Yu, Wenyue
2017-01-01
With the development of satellite load technology and very large scale integrated (VLSI) circuit technology, onboard real-time synthetic aperture radar (SAR) imaging systems have become a solution for allowing rapid response to disasters. A key goal of the onboard SAR imaging system design is to achieve high real-time processing performance with severe size, weight, and power consumption constraints. In this paper, we analyse the computational burden of the commonly used chirp scaling (CS) SAR imaging algorithm. To reduce the system hardware cost, we propose a partial fixed-point processing scheme. The fast Fourier transform (FFT), which is the most computation-sensitive operation in the CS algorithm, is processed with fixed-point, while other operations are processed with single precision floating-point. With the proposed fixed-point processing error propagation model, the fixed-point processing word length is determined. The fidelity and accuracy relative to conventional ground-based software processors is verified by evaluating both the point target imaging quality and the actual scene imaging quality. As a proof of concept, a field- programmable gate array—application-specific integrated circuit (FPGA-ASIC) hybrid heterogeneous parallel accelerating architecture is designed and realized. The customized fixed-point FFT is implemented using the 130 nm complementary metal oxide semiconductor (CMOS) technology as a co-processor of the Xilinx xc6vlx760t FPGA. A single processing board requires 12 s and consumes 21 W to focus a 50-km swath width, 5-m resolution stripmap SAR raw data with a granularity of 16,384 × 16,384. PMID:28672813
Yang, Chen; Li, Bingyi; Chen, Liang; Wei, Chunpeng; Xie, Yizhuang; Chen, He; Yu, Wenyue
2017-06-24
With the development of satellite load technology and very large scale integrated (VLSI) circuit technology, onboard real-time synthetic aperture radar (SAR) imaging systems have become a solution for allowing rapid response to disasters. A key goal of the onboard SAR imaging system design is to achieve high real-time processing performance with severe size, weight, and power consumption constraints. In this paper, we analyse the computational burden of the commonly used chirp scaling (CS) SAR imaging algorithm. To reduce the system hardware cost, we propose a partial fixed-point processing scheme. The fast Fourier transform (FFT), which is the most computation-sensitive operation in the CS algorithm, is processed with fixed-point, while other operations are processed with single precision floating-point. With the proposed fixed-point processing error propagation model, the fixed-point processing word length is determined. The fidelity and accuracy relative to conventional ground-based software processors is verified by evaluating both the point target imaging quality and the actual scene imaging quality. As a proof of concept, a field- programmable gate array-application-specific integrated circuit (FPGA-ASIC) hybrid heterogeneous parallel accelerating architecture is designed and realized. The customized fixed-point FFT is implemented using the 130 nm complementary metal oxide semiconductor (CMOS) technology as a co-processor of the Xilinx xc6vlx760t FPGA. A single processing board requires 12 s and consumes 21 W to focus a 50-km swath width, 5-m resolution stripmap SAR raw data with a granularity of 16,384 × 16,384.
47 CFR 101.143 - Minimum path length requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.143 Minimum path length requirements. (a) The... carrier fixed point-to-point microwave services must equal or exceed the value set forth in the table...
47 CFR 101.143 - Minimum path length requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.143 Minimum path length requirements. (a) The... carrier fixed point-to-point microwave services must equal or exceed the value set forth in the table...
47 CFR 101.143 - Minimum path length requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.143 Minimum path length requirements. (a) The... carrier fixed point-to-point microwave services must equal or exceed the value set forth in the table...
47 CFR 101.143 - Minimum path length requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.143 Minimum path length requirements. (a) The... carrier fixed point-to-point microwave services must equal or exceed the value set forth in the table...
47 CFR 101.143 - Minimum path length requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.143 Minimum path length requirements. (a) The... carrier fixed point-to-point microwave services must equal or exceed the value set forth in the table...
Fixed point theorems for generalized contractions in ordered metric spaces
NASA Astrophysics Data System (ADS)
O'Regan, Donal; Petrusel, Adrian
2008-05-01
The purpose of this paper is to present some fixed point results for self-generalized contractions in ordered metric spaces. Our results generalize and extend some recent results of A.C.M. Ran, M.C. Reurings [A.C.M. Ran, MEC. Reurings, A fixed point theorem in partially ordered sets and some applications to matrix equations, Proc. Amer. Math. Soc. 132 (2004) 1435-1443], J.J. Nieto, R. Rodríguez-López [J.J. Nieto, R. Rodríguez-López, Contractive mapping theorems in partially ordered sets and applications to ordinary differential equations, Order 22 (2005) 223-239; J.J. Nieto, R. Rodríguez-López, Existence and uniqueness of fixed points in partially ordered sets and applications to ordinary differential equations, Acta Math. Sin. (Engl. Ser.) 23 (2007) 2205-2212], J.J. Nieto, R.L. Pouso, R. Rodríguez-López [J.J. Nieto, R.L. Pouso, R. Rodríguez-López, Fixed point theorem theorems in ordered abstract sets, Proc. Amer. Math. Soc. 135 (2007) 2505-2517], A. Petrusel, I.A. Rus [A. Petrusel, I.A. Rus, Fixed point theorems in ordered L-spaces, Proc. Amer. Math. Soc. 134 (2006) 411-418] and R.P. Agarwal, M.A. El-Gebeily, D. O'Regan [R.P. Agarwal, M.A. El-Gebeily, D. O'Regan, Generalized contractions in partially ordered metric spaces, Appl. Anal., in press]. As applications, existence and uniqueness results for Fredholm and Volterra type integral equations are given.
Holló, Gábor; Ropo, Auli
2015-01-01
We investigated the intraocular pressure (IOP) lowering efficacy of preservative-free fixed and non-fixed combination of tafluprost 0.0015% and timolol 0.5% in pseudoexfoliative glaucoma (XFG). A per protocol worse eye analysis was made on all XFG patients who participated in a recent 6 month, prospective, randomized, double-masked, parallel group, multicenter phase III study. The mean time-wise IOP decreased by 8.62 to 10.25 mmHg (31.8 to 36.7%) in the fixed dose combination arm (15 patients) and by 5.38 to 11.35 mmHg (21.3 to 41.2%) in the non-fixed combination arm (13 patients), respectively (p < 0.001 for all comparisons). The results show that a preservative-free fixed dose combination of tafluprost and timolol provides a clinically significant IOP reduction in XFG, and may offer an advantage for the XFG patients with dry eye, due to its preservative-free nature.
Dark energy as a fixed point of the Einstein Yang-Mills Higgs equations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rinaldi, Massimiliano, E-mail: massimiliano.rinaldi@unitn.it
We study the Einstein Yang-Mills Higgs equations in the SO(3) representation on a isotropic and homogeneous flat Universe, in the presence of radiation and matter fluids. We map the equations of motion into an autonomous dynamical system of first-order differential equations and we find the equilibrium points. We show that there is only one stable fixed point that corresponds to an accelerated expanding Universe in the future. In the past, instead, there is an unstable fixed point that implies a stiff-matter domination. In between, we find three other unstable fixed points, corresponding, in chronological order, to radiation domination, to mattermore » domination, and, finally, to a transition from decelerated expansion to accelerated expansion. We solve the system numerically and we confirm that there are smooth trajectories that correctly describe the evolution of the Universe, from a remote past dominated by radiation to a remote future dominated by dark energy, passing through a matter-dominated phase.« less
Dark energy as a fixed point of the Einstein Yang-Mills Higgs equations
NASA Astrophysics Data System (ADS)
Rinaldi, Massimiliano
2015-10-01
We study the Einstein Yang-Mills Higgs equations in the SO(3) representation on a isotropic and homogeneous flat Universe, in the presence of radiation and matter fluids. We map the equations of motion into an autonomous dynamical system of first-order differential equations and we find the equilibrium points. We show that there is only one stable fixed point that corresponds to an accelerated expanding Universe in the future. In the past, instead, there is an unstable fixed point that implies a stiff-matter domination. In between, we find three other unstable fixed points, corresponding, in chronological order, to radiation domination, to matter domination, and, finally, to a transition from decelerated expansion to accelerated expansion. We solve the system numerically and we confirm that there are smooth trajectories that correctly describe the evolution of the Universe, from a remote past dominated by radiation to a remote future dominated by dark energy, passing through a matter-dominated phase.
Hackenberg, T D; Hineline, P N
1992-01-01
Pigeons chose between two schedules of food presentation, a fixed-interval schedule and a progressive-interval schedule that began at 0 s and increased by 20 s with each food delivery provided by that schedule. Choosing one schedule disabled the alternate schedule and stimuli until the requirements of the chosen schedule were satisfied, at which point both schedules were again made available. Fixed-interval duration remained constant within individual sessions but varied across conditions. Under reset conditions, completing the fixed-interval schedule not only produced food but also reset the progressive interval to its minimum. Blocks of sessions under the reset procedure were interspersed with sessions under a no-reset procedure, in which the progressive schedule value increased independent of fixed-interval choices. Median points of switching from the progressive to the fixed schedule varied systematically with fixed-interval value, and were consistently lower during reset than during no-reset conditions. Under the latter, each subject's choices of the progressive-interval schedule persisted beyond the point at which its requirements equaled those of the fixed-interval schedule at all but the highest fixed-interval value. Under the reset procedure, switching occurred at or prior to that equality point. These results qualitatively confirm molar analyses of schedule preference and some versions of optimality theory, but they are more adequately characterized by a model of schedule preference based on the cumulated values of multiple reinforcers, weighted in inverse proportion to the delay between the choice and each successive reinforcer. PMID:1548449
Entanglement entropy at infinite-randomness fixed points in higher dimensions.
Lin, Yu-Cheng; Iglói, Ferenc; Rieger, Heiko
2007-10-05
The entanglement entropy of the two-dimensional random transverse Ising model is studied with a numerical implementation of the strong-disorder renormalization group. The asymptotic behavior of the entropy per surface area diverges at, and only at, the quantum phase transition that is governed by an infinite-randomness fixed point. Here we identify a double-logarithmic multiplicative correction to the area law for the entanglement entropy. This contrasts with the pure area law valid at the infinite-randomness fixed point in the diluted transverse Ising model in higher dimensions.
Fixed Point Results of Locally Contractive Mappings in Ordered Quasi-Partial Metric Spaces
Arshad, Muhammad; Ahmad, Jamshaid
2013-01-01
Fixed point results for a self-map satisfying locally contractive conditions on a closed ball in an ordered 0-complete quasi-partial metric space have been established. Instead of monotone mapping, the notion of dominated mappings is applied. We have used weaker metric, weaker contractive conditions, and weaker restrictions to obtain unique fixed points. An example is given which shows that how this result can be used when the corresponding results cannot. Our results generalize, extend, and improve several well-known conventional results. PMID:24062629
Latif, Abdul; Mongkolkeha, Chirasak; Sintunavarat, Wutiphol
2014-01-01
We extend the notion of generalized weakly contraction mappings due to Choudhury et al. (2011) to generalized α-β-weakly contraction mappings. We show with examples that our new class of mappings is a real generalization of several known classes of mappings. We also establish fixed point results for such mappings in metric spaces. Applying our new results, we obtain fixed point results on ordinary metric spaces, metric spaces endowed with an arbitrary binary relation, and metric spaces endowed with graph.
Evolution families of conformal mappings with fixed points and the Löwner-Kufarev equation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goryainov, V V
2015-01-31
The paper is concerned with evolution families of conformal mappings of the unit disc to itself that fix an interior point and a boundary point. Conditions are obtained for the evolution families to be differentiable, and an existence and uniqueness theorem for an evolution equation is proved. A convergence theorem is established which describes the topology of locally uniform convergence of evolution families in terms of infinitesimal generating functions. The main result in this paper is the embedding theorem which shows that any conformal mapping of the unit disc to itself with two fixed points can be embedded into a differentiable evolution familymore » of such mappings. This result extends the range of the parametric method in the theory of univalent functions. In this way the problem of the mutual change of the derivative at an interior point and the angular derivative at a fixed point on the boundary is solved for a class of mappings of the unit disc to itself. In particular, the rotation theorem is established for this class of mappings. Bibliography: 27 titles.« less
Dynamical Crossovers in Prethermal Critical States.
Chiocchetta, Alessio; Gambassi, Andrea; Diehl, Sebastian; Marino, Jamir
2017-03-31
We study the prethermal dynamics of an interacting quantum field theory with an N-component order parameter and O(N) symmetry, suddenly quenched in the vicinity of a dynamical critical point. Depending on the initial conditions, the evolution of the order parameter, and of the response and correlation functions, can exhibit a temporal crossover between universal dynamical scaling regimes governed, respectively, by a quantum and a classical prethermal fixed point, as well as a crossover from a Gaussian to a non-Gaussian prethermal dynamical scaling. Together with a recent experiment, this suggests that quenches may be used in order to explore the rich variety of dynamical critical points occurring in the nonequilibrium dynamics of a quantum many-body system. We illustrate this fact by using a combination of renormalization group techniques and a nonperturbative large-N limit.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kainz, K; Prah, D; Ahunbay, E
2014-06-01
Purpose: A novel modulated arc therapy technique, mARC, enables superposition of step-and-shoot IMRT segments upon a subset of the optimization points (OPs) of a continuous-arc delivery. We compare two approaches to mARC planning: one with the number of OPs fixed throughout optimization, and another where the planning system determines the number of OPs in the final plan, subject to an upper limit defined at the outset. Methods: Fixed-OP mARC planning was performed for representative cases using Panther v. 5.01 (Prowess, Inc.), while variable-OP mARC planning used Monaco v. 5.00 (Elekta, Inc.). All Monaco planning used an upper limit of 91more » OPs; those OPs with minimal MU were removed during optimization. Plans were delivered, and delivery times recorded, on a Siemens Artiste accelerator using a flat 6MV beam with 300 MU/min rate. Dose distributions measured using ArcCheck (Sun Nuclear Corporation, Inc.) were compared with the plan calculation; the two were deemed consistent if they agreed to within 3.5% in absolute dose and 3.5 mm in distance-to-agreement among > 95% of the diodes within the direct beam. Results: Example cases included a prostate and a head-and-neck planned with a single arc and fraction doses of 1.8 and 2.0 Gy, respectively. Aside from slightly more uniform target dose for the variable-OP plans, the DVHs for the two techniques were similar. For the fixed-OP technique, the number of OPs was 38 and 39, and the delivery time was 228 and 259 seconds, respectively, for the prostate and head-and-neck cases. For the final variable-OP plans, there were 91 and 85 OPs, and the delivery time was 296 and 440 seconds, correspondingly longer than for fixed-OP. Conclusion: For mARC, both the fixed-OP and variable-OP approaches produced comparable-quality plans whose delivery was successfully verified. To keep delivery time per fraction short, a fixed-OP planning approach is preferred.« less
van Stralen, R A; Heesterbeek, P J C; Wymenga, A B
2015-11-01
In anteroposterior (AP)-gliding mobile-bearing total knee arthroplasty (TKA), the femoral component can theoretically slide forward resulting in a more anterior contact point, causing pain due to impingement. A lower lever arm of the extensor apparatus can also attribute to higher patella pressures and pain. The goal of this study was to determine the contact point in a cohort of mobile- and fixed-bearing TKAs, to determine whether the contact point lies more anteriorly in mobile-bearing TKA and to confirm whether this results in anterior knee pain. We used 38 fixed-bearing TKA and 40 mobile-bearing TKA from a randomized trial with straight lateral knee X-rays and measured the contact point. The functional outcome was measured by Knee Society Score at 12 months postoperatively. Pain scores were analysed using a VAS score (0-100 mm) in all patients at rest and when moving. Difficulty at rising up out of a chair was also assessed using a VAS score. The contact point in mobile-bearing TKA was situated at 59.5 % of the AP distance of the tibia and in the fixed-bearing TKA group at 66.1 % (P< 0.05). Patients with mobile- and fixed-bearing TKAs had similar knee scores, pain scores and difficulty in chair rise. No significant correlation was found between contact point and knee pain. The hypothesis of a more anterior contact point in the mobile-bearing cohort was confirmed but no correlation with functional and pain scores in this cohort could be found. The tibiofemoral contact point could not be correlated with a different clinical outcome and higher incidence of anterior knee pain. This study further adds to the knowledge on possible differences between mobile- and fixed-bearing prostheses. Next to that, bad outcomes could not be explained by CP. Case series, Level IV.
NASA Astrophysics Data System (ADS)
Edler, F.; Huang, K.
2016-12-01
Fifteen miniature fixed-point cells made of three different ceramic crucible materials (Al2O3, ZrO2, and Al2O3(86 %)+ZrO2(14 %)) were filled with pure palladium and used to calibrate type B thermocouples (Pt30 %Rh/Pt6 %Rh). A critical point by using miniature fixed points with small amounts of fixed-point material is the analysis of the melting curves, which are characterized by significant slopes during the melting process compared to flat melting plateaus obtainable using conventional fixed-point cells. The method of the extrapolated starting point temperature using straight line approximation of the melting plateau was applied to analyze the melting curves. This method allowed an unambiguous determination of an electromotive force (emf) assignable as melting temperature. The strict consideration of two constraints resulted in a unique, repeatable and objective method to determine the emf at the melting temperature within an uncertainty of about 0.1 μ V. The lifetime and long-term stability of the miniature fixed points was investigated by performing more than 100 melt/freeze cycles for each crucible of the different ceramic materials. No failure of the crucibles occurred indicating an excellent mechanical stability of the investigated miniature cells. The consequent limitation of heating rates to values below {± }3.5 K min^{-1} above 1100° C and the carefully and completely filled crucibles (the liquid palladium occupies the whole volume of the crucible) are the reasons for successfully preventing the crucibles from breaking. The thermal stability of the melting temperature of palladium was excellent when using the crucibles made of Al2O3(86 %)+ZrO2(14 %) and ZrO2. Emf drifts over the total duration of the long-term investigation were below a temperature equivalent of about 0.1 K-0.2 K.
Onsite Calibration of a Precision IPRT Based on Gallium and Gallium-Based Small-Size Eutectic Points
NASA Astrophysics Data System (ADS)
Sun, Jianping; Hao, Xiaopeng; Zeng, Fanchao; Zhang, Lin; Fang, Xinyun
2017-04-01
Onsite thermometer calibration with temperature scale transfer technology based on fixed points can effectively improve the level of industrial temperature measurement and calibration. The present work performs an onsite calibration of a precision industrial platinum resistance thermometer near room temperature. The calibration is based on a series of small-size eutectic points, including Ga-In (15.7°C), Ga-Sn (20.5°C), Ga-Zn (25.2°C), and a Ga fixed point (29.7°C), developed in a portable multi-point automatic realization apparatus. The temperature plateaus of the Ga-In, Ga-Sn, and Ga-Zn eutectic points and the Ga fixed point last for longer than 2 h, and their reproducibility was better than 5 mK. The device is suitable for calibrating non-detachable temperature sensors in advanced environmental laboratories and industrial fields.
Scaling in the vicinity of the four-state Potts fixed point
NASA Astrophysics Data System (ADS)
Blöte, H. W. J.; Guo, Wenan; Nightingale, M. P.
2017-08-01
We study a self-dual generalization of the Baxter-Wu model, employing results obtained by transfer matrix calculations of the magnetic scaling dimension and the free energy. While the pure critical Baxter-Wu model displays the critical behavior of the four-state Potts fixed point in two dimensions, in the sense that logarithmic corrections are absent, the introduction of different couplings in the up- and down triangles moves the model away from this fixed point, so that logarithmic corrections appear. Real couplings move the model into the first-order range, away from the behavior displayed by the nearest-neighbor, four-state Potts model. We also use complex couplings, which bring the model in the opposite direction characterized by the same type of logarithmic corrections as present in the four-state Potts model. Our finite-size analysis confirms in detail the existing renormalization theory describing the immediate vicinity of the four-state Potts fixed point.
van Maanen, Leendert; de Jong, Ritske; van Rijn, Hedderik
2014-01-01
When multiple strategies can be used to solve a type of problem, the observed response time distributions are often mixtures of multiple underlying base distributions each representing one of these strategies. For the case of two possible strategies, the observed response time distributions obey the fixed-point property. That is, there exists one reaction time that has the same probability of being observed irrespective of the actual mixture proportion of each strategy. In this paper we discuss how to compute this fixed-point, and how to statistically assess the probability that indeed the observed response times are generated by two competing strategies. Accompanying this paper is a free R package that can be used to compute and test the presence or absence of the fixed-point property in response time data, allowing for easy to use tests of strategic behavior. PMID:25170893
Matrix product density operators: Renormalization fixed points and boundary theories
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cirac, J.I.; Pérez-García, D., E-mail: dperezga@ucm.es; ICMAT, Nicolas Cabrera, Campus de Cantoblanco, 28049 Madrid
We consider the tensors generating matrix product states and density operators in a spin chain. For pure states, we revise the renormalization procedure introduced in (Verstraete et al., 2005) and characterize the tensors corresponding to the fixed points. We relate them to the states possessing zero correlation length, saturation of the area law, as well as to those which generate ground states of local and commuting Hamiltonians. For mixed states, we introduce the concept of renormalization fixed points and characterize the corresponding tensors. We also relate them to concepts like finite correlation length, saturation of the area law, as well asmore » to those which generate Gibbs states of local and commuting Hamiltonians. One of the main result of this work is that the resulting fixed points can be associated to the boundary theories of two-dimensional topological states, through the bulk-boundary correspondence introduced in (Cirac et al., 2011).« less
Fixed Point Learning Based Intelligent Traffic Control System
NASA Astrophysics Data System (ADS)
Zongyao, Wang; Cong, Sui; Cheng, Shao
2017-10-01
Fixed point learning has become an important tool to analyse large scale distributed system such as urban traffic network. This paper presents a fixed point learning based intelligence traffic network control system. The system applies convergence property of fixed point theorem to optimize the traffic flow density. The intelligence traffic control system achieves maximum road resources usage by averaging traffic flow density among the traffic network. The intelligence traffic network control system is built based on decentralized structure and intelligence cooperation. No central control is needed to manage the system. The proposed system is simple, effective and feasible for practical use. The performance of the system is tested via theoretical proof and simulations. The results demonstrate that the system can effectively solve the traffic congestion problem and increase the vehicles average speed. It also proves that the system is flexible, reliable and feasible for practical use.
Assessment of tungsten/rhenium thermocouples with metal-carbon eutectic fixed points up to 1500°C
NASA Astrophysics Data System (ADS)
Gotoh, M.
2013-09-01
Four Type A thermocouples and two Type C thermocouples were calibrated at the Au fixed point and Co-C and Pd-C eutectic fixed points. The thermocouples were exposed to 1330 °C for a total of 100 hours. The maximum drift due to the exposure was found to be 4.8 °C. The fixed-point calibration EMF of these thermocouples deviated by less than 0.86% from the temperature specified by the standards ASTM E230-2003 for Type C and GOSTR 8.585-2001 for Type A. The length of one of Type A thermocouples A52 is longer than the others by 150mm. Making use of this provision it was possible to place annealed part of A52 to the temperature gradient part of calibration arrangement every time. Therefore observed aging effect was as low as 0.5 °C compared to the other thermocouples.
Positive solutions of fractional integral equations by the technique of measure of noncompactness.
Nashine, Hemant Kumar; Arab, Reza; Agarwal, Ravi P; De la Sen, Manuel
2017-01-01
In the present study, we work on the problem of the existence of positive solutions of fractional integral equations by means of measures of noncompactness in association with Darbo's fixed point theorem. To achieve the goal, we first establish new fixed point theorems using a new contractive condition of the measure of noncompactness in Banach spaces. By doing this we generalize Darbo's fixed point theorem along with some recent results of (Aghajani et al. (J. Comput. Appl. Math. 260:67-77, 2014)), (Aghajani et al. (Bull. Belg. Math. Soc. Simon Stevin 20(2):345-358, 2013)), (Arab (Mediterr. J. Math. 13(2):759-773, 2016)), (Banaś et al. (Dyn. Syst. Appl. 18:251-264, 2009)), and (Samadi et al. (Abstr. Appl. Anal. 2014:852324, 2014)). We also derive corresponding coupled fixed point results. Finally, we give an illustrative example to verify the effectiveness and applicability of our results.
More asymptotic safety guaranteed
NASA Astrophysics Data System (ADS)
Bond, Andrew D.; Litim, Daniel F.
2018-04-01
We study interacting fixed points and phase diagrams of simple and semisimple quantum field theories in four dimensions involving non-Abelian gauge fields, fermions and scalars in the Veneziano limit. Particular emphasis is put on new phenomena which arise due to the semisimple nature of the theory. Using matter field multiplicities as free parameters, we find a large variety of interacting conformal fixed points with stable vacua and crossovers inbetween. Highlights include semisimple gauge theories with exact asymptotic safety, theories with one or several interacting fixed points in the IR, theories where one of the gauge sectors is both UV free and IR free, and theories with weakly interacting fixed points in the UV and the IR limits. The phase diagrams for various simple and semisimple settings are also given. Further aspects such as perturbativity beyond the Veneziano limit, conformal windows, and implications for model building are discussed.
Inflation, quintessence, and the origin of mass
NASA Astrophysics Data System (ADS)
Wetterich, C.
2015-08-01
In a unified picture both inflation and present dynamical dark energy arise from the same scalar field. The history of the Universe describes a crossover from a scale invariant "past fixed point" where all particles are massless, to a "future fixed point" for which spontaneous breaking of the exact scale symmetry generates the particle masses. The cosmological solution can be extrapolated to the infinite past in physical time - the universe has no beginning. This is seen most easily in a frame where particle masses and the Planck mass are field-dependent and increase with time. In this "freeze frame" the Universe shrinks and heats up during radiation and matter domination. In the equivalent, but singular Einstein frame cosmic history finds the familiar big bang description. The vicinity of the past fixed point corresponds to inflation. It ends at a first stage of the crossover. A simple model with no more free parameters than ΛCDM predicts for the primordial fluctuations a relation between the tensor amplitude r and the spectral index n, r = 8.19 (1 - n) - 0.137. The crossover is completed by a second stage where the beyond-standard-model sector undergoes the transition to the future fixed point. The resulting increase of neutrino masses stops a cosmological scaling solution, relating the present dark energy density to the present neutrino mass. At present our simple model seems compatible with all observational tests. We discuss how the fixed points can be rooted within quantum gravity in a crossover between ultraviolet and infrared fixed points. Then quantum properties of gravity could be tested both by very early and late cosmology.
NASA Astrophysics Data System (ADS)
Xiao, Long; Liu, Xinggao; Ma, Liang; Zhang, Zeyin
2018-03-01
Dynamic optimisation problem with characteristic times, widely existing in many areas, is one of the frontiers and hotspots of dynamic optimisation researches. This paper considers a class of dynamic optimisation problems with constraints that depend on the interior points either fixed or variable, where a novel direct pseudospectral method using Legendre-Gauss (LG) collocation points for solving these problems is presented. The formula for the state at the terminal time of each subdomain is derived, which results in a linear combination of the state at the LG points in the subdomains so as to avoid the complex nonlinear integral. The sensitivities of the state at the collocation points with respect to the variable characteristic times are derived to improve the efficiency of the method. Three well-known characteristic time dynamic optimisation problems are solved and compared in detail among the reported literature methods. The research results show the effectiveness of the proposed method.
Code of Federal Regulations, 2014 CFR
2014-10-01
... COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Common Carrier Fixed Point-to-Point Microwave Service § 101.705 Special showing for renewal of common carrier station...
Code of Federal Regulations, 2013 CFR
2013-10-01
... COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Common Carrier Fixed Point-to-Point Microwave Service § 101.705 Special showing for renewal of common carrier station...
Code of Federal Regulations, 2012 CFR
2012-10-01
... COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Common Carrier Fixed Point-to-Point Microwave Service § 101.705 Special showing for renewal of common carrier station...
Code of Federal Regulations, 2011 CFR
2011-10-01
... COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Common Carrier Fixed Point-to-Point Microwave Service § 101.705 Special showing for renewal of common carrier station...
NASA Astrophysics Data System (ADS)
Ragay-Enot, Monalisa; Lee, Young Hee; Kim, Yong-Gyoo
2017-07-01
A mini multi-fixed-point cell (length 118 mm, diameter 33 mm) containing three materials (In-Zn eutectic (mass fraction 3.8% Zn), Sn and Pb) in a single crucible was designed and fabricated for the easy and economical fixed-point calibration of industrial platinum resistance thermometers (IPRTs) for use in industrial temperature measurements. The melting and freezing behaviors of the metals were investigated and the phase transition temperatures were determined using a commercial dry-block calibrator. Results showed that the melting plateaus are generally easy to realize and are reproducible, flatter and of longer duration. On the other hand, the freezing process is generally difficult, especially for Sn, due to the high supercooling required to initiate freezing. The observed melting temperatures at optimum set conditions were 143.11 °C (In-Zn), 231.70 °C (Sn) and 327.15 °C (Pb) with expanded uncertainties (k = 2) of 0.12 °C, 0.10 °C and 0.13 °C, respectively. This multi-fixed-point cell can be treated as a sole reference temperature-generating system. Based on the results, the realization of melting points of the mini multi-fixed-point cell can be recommended for the direct calibration of IPRTs in industrial applications without the need for a reference thermometer.
A Case of Successful Surgical Repair for Pectus Arcuatum Using Chondrosternoplasty
Kim, Sang Yoon; Park, Samina; Kim, Eung Rae; Park, In Kyu; Kim, Young Tae; Kang, Chang Hyun
2016-01-01
Pectus arcuatum is a rare complex chest wall deformity. A 31-year-old female presented with a severely protruding upper sternum combined with a concave lower sternum. We planned a modified Ravitch-type operation. Through vertical mid-sternal incision, chondrectomies were performed from the second to fifth costal cartilages, saving the perichondrium. Horizontal osteotomy was performed in a wedge shape on the most protruding point, and followed by an additional partial osteotomy at the most concaved point. The harvested wedge-shape bone fragments were minced and re-implanted to the latter osteotomy site. The osteotomized sternum was fixed with multiple wirings. With chondrosternoplasty, a complex chest wall deformity can be corrected successfully. PMID:27298803
A Case of Successful Surgical Repair for Pectus Arcuatum Using Chondrosternoplasty.
Kim, Sang Yoon; Park, Samina; Kim, Eung Rae; Park, In Kyu; Kim, Young Tae; Kang, Chang Hyun
2016-06-01
Pectus arcuatum is a rare complex chest wall deformity. A 31-year-old female presented with a severely protruding upper sternum combined with a concave lower sternum. We planned a modified Ravitch-type operation. Through vertical mid-sternal incision, chondrectomies were performed from the second to fifth costal cartilages, saving the perichondrium. Horizontal osteotomy was performed in a wedge shape on the most protruding point, and followed by an additional partial osteotomy at the most concaved point. The harvested wedge-shape bone fragments were minced and re-implanted to the latter osteotomy site. The osteotomized sternum was fixed with multiple wirings. With chondrosternoplasty, a complex chest wall deformity can be corrected successfully.
Quintano Jiménez, J A; Ginel Mendoza, L; Entrenas Costa, L M; Polo García, J
2016-02-01
The fixed-dose combination fluticasone propionate/formoterol (FPF) is a novel combination of a widely known and used inhaled glucocorticoid (IGC) and a long-acting β2-adrenergic agonist (LABA), available for the first time in a single device. This fixed-dose combination of FPF has a demonstrated efficacy and safety profile in clinical trials compared with its individual components and other fixed-dose combinations of IGC/LABA and is indicated for the treatment of persistent asthma in adults and adolescents. FPF is available in a wide range of doses that can adequately cover the therapeutic steps recommended by treatment guidelines, constituting a fixed-dose combination of GCI/LABA that is effective, rapid, well tolerated and with a reasonable acquisition cost. Various assessment agencies of the Spanish Autonomous Communities consider this combination to be an appropriate alternative therapy for asthma in the primary care setting. Copyright © 2016 Elsevier España, S.L.U. y Sociedad Española de Medicina Rural y Generalista (SEMERGEN). All rights reserved.
47 CFR 101.703 - Permissible communications.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false Permissible communications. 101.703 Section 101.703 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Common Carrier Fixed Point-to-Point Microwave Service § 101.703 Permissible...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 5 2013-10-01 2013-10-01 false Eligibility. 101.601 Section 101.601 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Private Operational Fixed Point-to-Point Microwave Service § 101.601 Eligibility. Any person, or...
47 CFR 101.703 - Permissible communications.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false Permissible communications. 101.703 Section 101.703 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Common Carrier Fixed Point-to-Point Microwave Service § 101.703 Permissible...
47 CFR 101.135 - Shared use of radio stations and the offering of private carrier service.
Code of Federal Regulations, 2012 CFR
2012-10-01
... COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101... Operational Fixed Point-to-Point Microwave radio stations may share the use of their facilities on a non...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Eligibility. 101.601 Section 101.601 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Private Operational Fixed Point-to-Point Microwave Service § 101.601 Eligibility. Any person, or...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false Eligibility. 101.601 Section 101.601 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Private Operational Fixed Point-to-Point Microwave Service § 101.601 Eligibility. Any person, or...
47 CFR 101.135 - Shared use of radio stations and the offering of private carrier service.
Code of Federal Regulations, 2010 CFR
2010-10-01
... COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101... Operational Fixed Point-to-Point Microwave radio stations may share the use of their facilities on a non...
47 CFR 101.703 - Permissible communications.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 5 2013-10-01 2013-10-01 false Permissible communications. 101.703 Section 101.703 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Common Carrier Fixed Point-to-Point Microwave Service § 101.703 Permissible...
47 CFR 101.135 - Shared use of radio stations and the offering of private carrier service.
Code of Federal Regulations, 2011 CFR
2011-10-01
... COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101... Operational Fixed Point-to-Point Microwave radio stations may share the use of their facilities on a non...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Eligibility. 101.601 Section 101.601 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Private Operational Fixed Point-to-Point Microwave Service § 101.601 Eligibility. Any person, or...
47 CFR 101.703 - Permissible communications.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Permissible communications. 101.703 Section 101.703 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Common Carrier Fixed Point-to-Point Microwave Service § 101.703 Permissible...
47 CFR 101.135 - Shared use of radio stations and the offering of private carrier service.
Code of Federal Regulations, 2014 CFR
2014-10-01
... COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101... Operational Fixed Point-to-Point Microwave radio stations may share the use of their facilities on a non...
47 CFR 101.135 - Shared use of radio stations and the offering of private carrier service.
Code of Federal Regulations, 2013 CFR
2013-10-01
... COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101... Operational Fixed Point-to-Point Microwave radio stations may share the use of their facilities on a non...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false Eligibility. 101.601 Section 101.601 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Private Operational Fixed Point-to-Point Microwave Service § 101.601 Eligibility. Any person, or...
47 CFR 101.703 - Permissible communications.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Permissible communications. 101.703 Section 101.703 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Common Carrier Fixed Point-to-Point Microwave Service § 101.703 Permissible...
Regulator dependence of fixed points in quantum Einstein gravity with R 2 truncation
NASA Astrophysics Data System (ADS)
Nagy, S.; Fazekas, B.; Peli, Z.; Sailer, K.; Steib, I.
2018-03-01
We performed a functional renormalization group analysis for the quantum Einstein gravity including a quadratic term in the curvature. The ultraviolet non-gaussian fixed point and its critical exponent for the correlation length are identified for different forms of regulators in case of dimension 3. We searched for that optimized regulator where the physical quantities show the least regulator parameter dependence. It is shown that the Litim regulator satisfies this condition. The infrared fixed point has also been investigated, it is found that the exponent is insensitive to the third coupling introduced by the R 2 term.
Fixed Point Results for G-α-Contractive Maps with Application to Boundary Value Problems
Roshan, Jamal Rezaei
2014-01-01
We unify the concepts of G-metric, metric-like, and b-metric to define new notion of generalized b-metric-like space and discuss its topological and structural properties. In addition, certain fixed point theorems for two classes of G-α-admissible contractive mappings in such spaces are obtained and some new fixed point results are derived in corresponding partially ordered space. Moreover, some examples and an application to the existence of a solution for the first-order periodic boundary value problem are provided here to illustrate the usability of the obtained results. PMID:24895655
A regularity result for fixed points, with applications to linear response
NASA Astrophysics Data System (ADS)
Sedro, Julien
2018-04-01
In this paper, we show a series of abstract results on fixed point regularity with respect to a parameter. They are based on a Taylor development taking into account a loss of regularity phenomenon, typically occurring for composition operators acting on spaces of functions with finite regularity. We generalize this approach to higher order differentiability, through the notion of an n-graded family. We then give applications to the fixed point of a nonlinear map, and to linear response in the context of (uniformly) expanding dynamics (theorem 3 and corollary 2), in the spirit of Gouëzel-Liverani.
Tank Tests of NACA Model 40 Series of Hulls for Small Flying Boats and Amphibians
NASA Technical Reports Server (NTRS)
Parkinson, John B; Dawson, John R
1937-01-01
The NACA model 40 series of flying-boat hull models consists of 2 forebodies and 3 afterbodies combined to provide several forms suitable for use in small marine aircraft. One forebody is the usual form with hollow bow sections and the other has a bottom surface that is completely developable from bow to step. The afterbodies include a short pointed afterbody with an extension for the tail surfaces, a long afterbody similar to that of a seaplane float but long enough to carry the tail surfaces, and a third obtained by fitting a second step in the latter afterbody. The various combinations were tested in the NACA Tank by the general method over a suitable range of loadings. Fixed-trim tests were made for all speeds likely to be used and free-to-trim tests were made at low speeds to slightly beyond the hump speed. The characteristics of the hulls at best trim angles have been deduced from the data of the tests at fixed trim angles and are given in the form of nondimensional coefficients applicable to any size hull.
NASA Astrophysics Data System (ADS)
Becherer, Nico; Hesser, Jürgen; Kornmesser, Ulrike; Schranz, Dietmar; Männer, Reinhard
2007-03-01
Simulation systems are becoming increasingly essential in medical education. Hereby, capturing the physical behaviour of the real world requires a sophisticated modelling of instruments within the virtual environment. Most models currently used are not capable of user interactive simulations due to the computation of the complex underlying analytical equations. Alternatives are often based on simplifying mass-spring systems, being able to deliver high update rates that come at the cost of less realistic motion. In addition, most techniques are limited to narrow and tubular vessel structures or restrict shape alterations to two degrees of freedom, not allowing instrument deformations like torsion. In contrast, our approach combines high update rates with highly realistic motion and can in addition be used with respect to arbitrary structures like vessels or cavities (e.g. atrium, ventricle) without limiting the degrees of freedom. Based on energy minimization, bending energies and vessel structures are considered as linear elastic elements; energies are evaluated at regularly spaced points on the instrument, while the distance of the points is fixed, i.e. we simulate an articulated structure of joints with fixed connections between them. Arbitrary tissue structures are modeled through adaptive distance fields and are connected by nodes via an undirected graph system. The instrument points are linked to nodes by a system of rules. Energy minimization uses a Quasi Newton method without preconditioning and, hereby, gradients are estimated using a combination of analytical and numerical terms. Results show a high quality in motion simulation when compared to a phantom model. The approach is also robust and fast. Simulating an instrument with 100 joints runs at 100 Hz on a 3 GHz PC.
NASA Astrophysics Data System (ADS)
Astrua, M.; Iacomini, L.; Battuello, M.
2008-10-01
The calibration of platinum-based thermocouples from 420 °C to 1,100 ˚C is currently carried out at INRIM making use of two different apparatus: for temperatures below 930 ˚C, a potassium gas-controlled heat pipe (GCHP) is used, whereas a metal-block furnace is adopted for higher temperatures. The standard uncertainty of the reference temperature obtained in the lower temperature range is almost one order of magnitude better than in the higher temperature range. A sealed copper cell was investigated to see if it could be used to calibrate thermocouples above 930 ˚C with a lower uncertainty than our current procedures allowed. The cell was characterized with Type S and Pt/Pd thermocouples and with an HTPRT. The freezing plateaux were flat within 0.01 ˚C and lasted up to 1 h with a repeatability of 0.02 ˚C. The temperature of the cell was determined with a standard uncertainty of 0.04 ˚C. Hence, the copper cell was found to be superior to the comparator furnace for the calibration of platinum-based thermocouples because of the significant decrease in the uncertainty that it provides. An analysis was also carried out on the calibration of Pt/Pd thermocouples, and it was found that the combined use of the potassium GCHP and the Cu fixed-point cell is adequate to exploit the potential of these sensors in the range from 420 °C to 1,084 °C. A comparison with a fixed-point calibration was also made which gave rise to agreement within 0.07 ˚C between the two approaches.
Universality of modular symmetries in two-dimensional magnetotransport
NASA Astrophysics Data System (ADS)
Olsen, K. S.; Limseth, H. S.; Lütken, C. A.
2018-01-01
We analyze experimental quantum Hall data from a wide range of different materials, including semiconducting heterojunctions, thin films, surface layers, graphene, mercury telluride, bismuth antimonide, and black phosphorus. The fact that these materials have little in common, except that charge transport is effectively two-dimensional, shows how robust and universal the quantum Hall phenomenon is. The scaling and fixed point data we analyzed appear to show that magnetotransport in two dimensions is governed by a small number of universality classes that are classified by modular symmetries, which are infinite discrete symmetries not previously seen in nature. The Hall plateaux are (infrared) stable fixed points of the scaling-flow, and quantum critical points (where the wave function is delocalized) are unstable fixed points of scaling. Modular symmetries are so rigid that they in some cases fix the global geometry of the scaling flow, and therefore predict the exact location of quantum critical points, as well as the shape of flow lines anywhere in the phase diagram. We show that most available experimental quantum Hall scaling data are in good agreement with these predictions.
Group delay variations of GPS transmitting and receiving antennas
NASA Astrophysics Data System (ADS)
Wanninger, Lambert; Sumaya, Hael; Beer, Susanne
2017-09-01
GPS code pseudorange measurements exhibit group delay variations at the transmitting and the receiving antenna. We calibrated C1 and P2 delay variations with respect to dual-frequency carrier phase observations and obtained nadir-dependent corrections for 32 satellites of the GPS constellation in early 2015 as well as elevation-dependent corrections for 13 receiving antenna models. The combined delay variations reach up to 1.0 m (3.3 ns) in the ionosphere-free linear combination for specific pairs of satellite and receiving antennas. Applying these corrections to the code measurements improves code/carrier single-frequency precise point positioning, ambiguity fixing based on the Melbourne-Wübbena linear combination, and determination of ionospheric total electron content. It also affects fractional cycle biases and differential code biases.
Development of Fixed-Point Cells at the SMU
NASA Astrophysics Data System (ADS)
Ďuriš, S.; Ranostaj, J.; Palenčár, R.
2008-06-01
One of the research programs realized at the thermometry laboratory of the Slovak Institute of Metrology (SMU) in recent years has focused on the development of fixed-point cells. In the frame of this research, several primary cells for realization of the International Temperature Scale of 1990 (ITS-90) and several secondary cells for industrial thermometer calibrations were built and studied. This article discusses primary cells for the gallium and mercury fixed points and miniature cells for the zinc point that were developed at the SMU. Information about the cell designs is provided, the materials that were used are specified, and the procedures for their manufacture are described. Briefly, the realization of the fixed points of mercury, gallium, and zinc by using these cells is also described. Many experiments were carried out to study the characteristics of these cells. One of the gallium cells was compared with the circulating transfer cell during the key comparison CCT-K3, and it and the mercury cell were used for the EUROMET Project No. 552. The results of the experiments together with the results of the comparisons show the high quality of these cells. Secondary zinc-point cells were compared against SMU primary zinc-point cells. The comparison shows agreement within 0.12 mK.
Glassy phase in quenched disordered crystalline membranes
NASA Astrophysics Data System (ADS)
Coquand, O.; Essafi, K.; Kownacki, J.-P.; Mouhanna, D.
2018-03-01
We investigate the flat phase of D -dimensional crystalline membranes embedded in a d -dimensional space and submitted to both metric and curvature quenched disorders using a nonperturbative renormalization group approach. We identify a second-order phase transition controlled by a finite-temperature, finite-disorder fixed point unreachable within the leading order of ɛ =4 -D and 1 /d expansions. This critical point divides the flow diagram into two basins of attraction: that associated with the finite-temperature fixed point controlling the long-distance behavior of disorder-free membranes and that associated with the zero-temperature, finite-disorder fixed point. Our work thus strongly suggests the existence of a whole low-temperature glassy phase for quenched disordered crystalline membranes and, possibly, for graphene and graphene-like compounds.
Chen, Ruey; Chan, Pi-Tuan; Chu, Hsin; Lin, Yu-Cih; Chang, Pi-Chen; Chen, Chien-Yu; Chou, Kuei-Ru
2017-01-01
This is the first meta-analysis to compare the treatment effects and safety of administering donepezil alone versus a combination of memantine and donepezil to treat patients with moderate to severe Alzheimer Disease, particularly regarding cognitive functions, behavioral and psychological symptoms in dementia (BPSD), and global functions. PubMed, Medline, Embase, PsycINFO, and Cochrane databases were used to search for English and non-English articles for inclusion in the meta-analysis to evaluate the effect size and incidence of adverse drug reactions of different treatments. Compared with patients who received donepezil alone, those who received donepezil in combination with memantine exhibited limited improvements in cognitive functions (g = 0.378, p < .001), BPSD (g = -0.878, p < .001) and global functions (g = -0.585, p = .004). Gradual titration of memantine plus a fixed dose and gradual titration of donepezil as well as a fixed dose and gradual titration of memantine resulted in limited improvements in cognitive functions(g = 0.371, p = .005), BPSD(g = -0.913, p = .001), and global functions(g = -0.371, p = .001). Both in the 24th week and at the final evaluation point, the combination of donepezil and memantine led to greater improvement in cognitive functions, BPSD, and global functions than did donepezil alone in patients with moderate to severe Alzheimer Disease.
Combining states without scale hierarchies with ordered parton showers
Fischer, Nadine; Prestel, Stefan
2017-09-12
Here, we present a parameter-free scheme to combine fixed-order multi-jet results with parton-shower evolution. The scheme produces jet cross sections with leading-order accuracy in the complete phase space of multiple emissions, resumming large logarithms when appropriate, while not arbitrarily enforcing ordering on momentum configurations beyond the reach of the parton-shower evolution equation. This then requires the development of a matrix-element correction scheme for complex phase-spaces including ordering conditions as well as a systematic scale-setting procedure for unordered phase-space points. Our algorithm does not require a merging-scale parameter. We implement the new method in the Vincia framework and compare to LHCmore » data.« less
Influence of the Cavity Length on the Behavior of Hybrid Fixed-Point Cells Constructed at INRIM
NASA Astrophysics Data System (ADS)
Battuello, M.; Girard, F.; Florio, M.
2015-03-01
Hybrid cells with double carbon/carbon sheets are used at the Istituto Nazionale di Ricerca Metrologica (INRIM) for the realization of both pure metal fixed points and high-temperature metal-carbon eutectic points. Cells for the Cu and Co-C fixed points have been prepared to be used in the high-temperature fixed-point project of the Comité Consultatif de Thermométrie. The results of the evaluation processes were not completely satisfactory for the INRIM cells because of their low transition temperatures with respect to the best cells, and of a rather large melting range for the Co-C cell. A new design of the cells was devised, and considerable improvements were achieved with respect to the transition temperature, and the plateau shape and duration. As for the Cu point, the duration of the freezing plateaux increased by more than 50 % and the freezing temperature increased by 18 mK. As for the Co-C point, the melting temperature, expressed in terms of the point of inflection of the melting curve, increased by about 70 mK. The melting range of the plateaux, expressed as a difference was reduced from about 180 mK to about 130 mK, with melting times increased by about 50 %, as a consequence of an improvement of flatness and run-off of the plateaux.
Existence of tripled fixed points for a class of condensing operators in Banach spaces.
Karakaya, Vatan; Bouzara, Nour El Houda; Doğan, Kadri; Atalan, Yunus
2014-01-01
We give some results concerning the existence of tripled fixed points for a class of condensing operators in Banach spaces. Further, as an application, we study the existence of solutions for a general system of nonlinear integral equations.
Contractive type non-self mappings on metric spaces of hyperbolic type
NASA Astrophysics Data System (ADS)
Ciric, Ljubomir B.
2006-05-01
Let (X,d) be a metric space of hyperbolic type and K a nonempty closed subset of X. In this paper we study a class of mappings from K into X (not necessarily self-mappings on K), which are defined by the contractive condition (2.1) below, and a class of pairs of mappings from K into X which satisfy the condition (2.28) below. We present fixed point and common fixed point theorems which are generalizations of the corresponding fixed point theorems of Ciric [L.B. Ciric, Quasi-contraction non-self mappings on Banach spaces, Bull. Acad. Serbe Sci. Arts 23 (1998) 25-31; L.B. Ciric, J.S. Ume, M.S. Khan, H.K.T. Pathak, On some non-self mappings, Math. Nachr. 251 (2003) 28-33], Rhoades [B.E. Rhoades, A fixed point theorem for some non-self mappings, Math. Japon. 23 (1978) 457-459] and many other authors. Some examples are presented to show that our results are genuine generalizations of known results from this area.
The evolving Planck mass in classically scale-invariant theories
NASA Astrophysics Data System (ADS)
Kannike, K.; Raidal, M.; Spethmann, C.; Veermäe, H.
2017-04-01
We consider classically scale-invariant theories with non-minimally coupled scalar fields, where the Planck mass and the hierarchy of physical scales are dynamically generated. The classical theories possess a fixed point, where scale invariance is spontaneously broken. In these theories, however, the Planck mass becomes unstable in the presence of explicit sources of scale invariance breaking, such as non-relativistic matter and cosmological constant terms. We quantify the constraints on such classical models from Big Bang Nucleosynthesis that lead to an upper bound on the non-minimal coupling and require trans-Planckian field values. We show that quantum corrections to the scalar potential can stabilise the fixed point close to the minimum of the Coleman-Weinberg potential. The time-averaged motion of the evolving fixed point is strongly suppressed, thus the limits on the evolving gravitational constant from Big Bang Nucleosynthesis and other measurements do not presently constrain this class of theories. Field oscillations around the fixed point, if not damped, contribute to the dark matter density of the Universe.
Efficacy and Safety of a Single-Pill Fixed-Dose Combination of Azilsartan and Amlodipine.
Motozato, Kota; Miura, Shin-Ichiro; Shiga, Yuhei; Kusumoto, Takaaki; Saku, Keijiro
2016-12-01
Guidelines for the management of hypertension recommend the use of drugs with different mechanisms of action in antihypertensive regimens that include single-pill fixed-dose combinations of medications. There is some controversy regarding which single-pill fixed-dose combinations of angiotensin II type 1 receptor blockers (ARBs) and calcium channel blockers (CCBs) are effective at reducing blood pressure (BP). Forty hypertensive patients who were receiving a single-pill fixed-dose combination of valsartan 80 mg/day and amlodipine 5 mg/day or irbesartan 100 mg/day and amlodipine 5 mg/day were enrolled. They were randomly divided into two treatment groups, a group that changed to a single-pill fixed-dose combination of azilsartan 20 mg/day and amlodipine 5 mg/day (changeover group) and a group that continued to receive valsartan 80 mg/day and amlodipine 5 mg/day or irbesartan 100 mg/day and amlodipine 5 mg/day (control group), and treated for 16 weeks. There were no significant differences in systolic blood pressure (SBP), diastolic blood pressure (DBP) or pulse rate (PR) at 16 weeks between the control and changeover groups. In addition, there were no significant changes in biochemical parameters throughout the study period in both groups. The ability of a single-pill fixed-dose combination of azilsartan and amlodipine to reduce BP may be comparable to that of a combination of valsartan and amlodipine or irbesartan and amlodipine.
Kim, Kyung-Jin; Kim, Sang-Hyun; Yoon, Young Won; Rha, Seung-Woon; Hong, Soon-Jun; Kwak, Choong-Hwan; Kim, Weon; Nam, Chang-Wook; Rhee, Moo-Yong; Park, Tae-Ho; Hong, Taek-Jong; Park, Sungha; Ahn, Youngkeun; Lee, Namho; Jeon, Hui-Kyung; Jeon, Dong-Woon; Han, Kyoo-Rok; Moon, Keon-Woong; Chae, In-Ho; Kim, Hyo-Soo
2016-10-01
We aimed to compare the effects of fixed-dose combinations of ezetimibe plus rosuvastatin to rosuvastatin alone in patients with primary hypercholesterolemia, including a subgroup analysis of patients with diabetes mellitus (DM) or metabolic syndrome (MetS). This multicenter eight-week randomized double-blind phase III study evaluated the safety and efficacy of fixed-dose combinations of ezetimibe 10 mg plus rosuvastatin, compared with rosuvastatin alone in patients with primary hypercholesterolemia. Four hundred and seven patients with primary hypercholesterolemia who required lipid-lowering treatment according to the ATP III guideline were randomized to one of the following six treatments for 8 weeks: fixed-dose combinations with ezetimibe 10 mg daily plus rosuvastatin (5, 10, or 20 mg daily) or rosuvastatin alone (5, 10, or 20 mg daily). Fixed-dose combination of ezetimibe plus rosuvastatin significantly reduced LDL cholesterol, total cholesterol, and triglyceride levels compared with rosuvastatin alone. Depending on the rosuvastatin dose, these fixed-dose combinations of ezetimibe plus rosuvastatin provided LDL cholesterol, total cholesterol, and triglyceride reductions of 56%-63%, 37%-43%, and 19%-24%, respectively. Moreover, the effect of combination treatment on cholesterol levels was more pronounced in patients with DM or MetS than in non-DM or non-MetS patients, respectively, whereas the effect of rosuvastatin alone did not differ between DM vs non-DM or MetS vs non-MetS patients. Fixed-dose combinations of ezetimibe and rosuvastatin provided significantly superior efficacy to rosuvastatin alone in lowering LDL cholesterol, total cholesterol, and triglyceride levels. Moreover, the reduction rate was greater in patients with DM or MetS. © 2016 The Authors Cardiovascular Therapeutics Published by John Wiley & Sons Ltd.
Fang, Yuan; Ling, Zhihong; Sun, Xinghuai
2015-01-01
Glaucoma is a common eye disease that can lead to irreversible vision loss if left untreated. The early diagnosis and treatment of primary open-angle glaucoma is challenging, and visual impairment in Chinese glaucoma patients is a serious concern. Most of these patients need more than one topical antiglaucoma agent to control their intraocular pressures (IOPs). In the People’s Republic of China, the daily cost of different glaucoma medication varies greatly, and the treatment habits differ throughout the country. Prostaglandin analogs (PGAs) are recommended as first-line monotherapy, because of their efficacy and low risk of systemic side effects. Fixed-combination drops, particularly PGA-based fixed combinations, have recently been developed and used in patients with progression or who have failed to achieve their target IOPs. Here, we reviewed the current literature on the use of bimatoprost-timolol fixed combination (BTFC) in the People’s Republic of China. BTFC has achieved good efficacy and tolerability in Chinese clinical trials. In addition, BTFC is more cost effective compared with other fixed combinations available in the People’s Republic of China. Fixed-combination drops may offer benefits, such as keeping the ocular surface healthy, convenience of administration, and improvement in long-term adherence and quality of life. Therefore, BTFC has great potential for the treatment of Chinese glaucoma patients. However, the long-term efficacy of BTFC, comparisons of BTFC with other fixed-combination drugs, and treatment adherence and persistence with treatment in Chinese patients are unknown and will require further study. PMID:25999695
NASA Astrophysics Data System (ADS)
Zeng, Lu-Chuan; Yao, Jen-Chih
2006-09-01
Recently, Agarwal, Cho, Li and Huang [R.P. Agarwal, Y.J. Cho, J. Li, N.J. Huang, Stability of iterative procedures with errors approximating common fixed points for a couple of quasi-contractive mappings in q-uniformly smooth Banach spaces, J. Math. Anal. Appl. 272 (2002) 435-447] introduced the new iterative procedures with errors for approximating the common fixed point of a couple of quasi-contractive mappings and showed the stability of these iterative procedures with errors in Banach spaces. In this paper, we introduce a new concept of a couple of q-contractive-like mappings (q>1) in a Banach space and apply these iterative procedures with errors for approximating the common fixed point of the couple of q-contractive-like mappings. The results established in this paper improve, extend and unify the corresponding ones of Agarwal, Cho, Li and Huang [R.P. Agarwal, Y.J. Cho, J. Li, N.J. Huang, Stability of iterative procedures with errors approximating common fixed points for a couple of quasi-contractive mappings in q-uniformly smooth Banach spaces, J. Math. Anal. Appl. 272 (2002) 435-447], Chidume [C.E. Chidume, Approximation of fixed points of quasi-contractive mappings in Lp spaces, Indian J. Pure Appl. Math. 22 (1991) 273-386], Chidume and Osilike [C.E. Chidume, M.O. Osilike, Fixed points iterations for quasi-contractive maps in uniformly smooth Banach spaces, Bull. Korean Math. Soc. 30 (1993) 201-212], Liu [Q.H. Liu, On Naimpally and Singh's open questions, J. Math. Anal. Appl. 124 (1987) 157-164; Q.H. Liu, A convergence theorem of the sequence of Ishikawa iterates for quasi-contractive mappings, J. Math. Anal. Appl. 146 (1990) 301-305], Osilike [M.O. Osilike, A stable iteration procedure for quasi-contractive maps, Indian J. Pure Appl. Math. 27 (1996) 25-34; M.O. Osilike, Stability of the Ishikawa iteration method for quasi-contractive maps, Indian J. Pure Appl. Math. 28 (1997) 1251-1265] and many others in the literature.
50 CFR 86.13 - What is boating infrastructure?
Code of Federal Regulations, 2010 CFR
2010-10-01
..., currents, etc., that provide a temporary safe anchorage point or harbor of refuge during storms); (f) Floating docks and fixed piers; (g) Floating and fixed breakwaters; (h) Dinghy docks (floating or fixed...
Parallel Fixed Point Implementation of a Radial Basis Function Network in an FPGA
de Souza, Alisson C. D.; Fernandes, Marcelo A. C.
2014-01-01
This paper proposes a parallel fixed point radial basis function (RBF) artificial neural network (ANN), implemented in a field programmable gate array (FPGA) trained online with a least mean square (LMS) algorithm. The processing time and occupied area were analyzed for various fixed point formats. The problems of precision of the ANN response for nonlinear classification using the XOR gate and interpolation using the sine function were also analyzed in a hardware implementation. The entire project was developed using the System Generator platform (Xilinx), with a Virtex-6 xc6vcx240t-1ff1156 as the target FPGA. PMID:25268918
Expected Number of Fixed Points in Boolean Networks with Arbitrary Topology.
Mori, Fumito; Mochizuki, Atsushi
2017-07-14
Boolean network models describe genetic, neural, and social dynamics in complex networks, where the dynamics depend generally on network topology. Fixed points in a genetic regulatory network are typically considered to correspond to cell types in an organism. We prove that the expected number of fixed points in a Boolean network, with Boolean functions drawn from probability distributions that are not required to be uniform or identical, is one, and is independent of network topology if only a feedback arc set satisfies a stochastic neutrality condition. We also demonstrate that the expected number is increased by the predominance of positive feedback in a cycle.
An investigation of the convergence to the stationary state in the Hassell mapping
NASA Astrophysics Data System (ADS)
de Mendonça, Hans M. J.; Leonel, Edson D.; de Oliveira, Juliano A.
2017-01-01
We investigate the convergence to the fixed point and near it in a transcritical bifurcation observed in a Hassell mapping. We considered a phenomenological description which was reinforced by a theoretical description. At the bifurcation, we confirm the convergence for the fixed point is characterized by a homogeneous function with three exponents. Near the bifurcation the decay to the fixed point is exponential with a relaxation time given by a power law. Although the expression of the mapping is different from the traditional logistic mapping, at the bifurcation and near it, the local dynamics is essentially the same for either mappings.
Automated Parameter Studies Using a Cartesian Method
NASA Technical Reports Server (NTRS)
Murman, Scott M.; Aftosimis, Michael J.; Nemec, Marian
2004-01-01
Computational Fluid Dynamics (CFD) is now routinely used to analyze isolated points in a design space by performing steady-state computations at fixed flight conditions (Mach number, angle of attack, sideslip), for a fixed geometric configuration of interest. This "point analysis" provides detailed information about the flowfield, which aides an engineer in understanding, or correcting, a design. A point analysis is typically performed using high fidelity methods at a handful of critical design points, e.g. a cruise or landing configuration, or a sample of points along a flight trajectory.
Estimation of satellite position, clock and phase bias corrections
NASA Astrophysics Data System (ADS)
Henkel, Patrick; Psychas, Dimitrios; Günther, Christoph; Hugentobler, Urs
2018-05-01
Precise point positioning with integer ambiguity resolution requires precise knowledge of satellite position, clock and phase bias corrections. In this paper, a method for the estimation of these parameters with a global network of reference stations is presented. The method processes uncombined and undifferenced measurements of an arbitrary number of frequencies such that the obtained satellite position, clock and bias corrections can be used for any type of differenced and/or combined measurements. We perform a clustering of reference stations. The clustering enables a common satellite visibility within each cluster and an efficient fixing of the double difference ambiguities within each cluster. Additionally, the double difference ambiguities between the reference stations of different clusters are fixed. We use an integer decorrelation for ambiguity fixing in dense global networks. The performance of the proposed method is analysed with both simulated Galileo measurements on E1 and E5a and real GPS measurements of the IGS network. We defined 16 clusters and obtained satellite position, clock and phase bias corrections with a precision of better than 2 cm.
Generalized contractive mappings and weakly α-admissible pairs in G-metric spaces.
Hussain, N; Parvaneh, V; Hoseini Ghoncheh, S J
2014-01-01
The aim of this paper is to present some coincidence and common fixed point results for generalized (ψ, φ)-contractive mappings using partially weakly G-α-admissibility in the setup of G-metric space. As an application of our results, periodic points of weakly contractive mappings are obtained. We also derive certain new coincidence point and common fixed point theorems in partially ordered G-metric spaces. Moreover, some examples are provided here to illustrate the usability of the obtained results.
Generalized Contractive Mappings and Weakly α-Admissible Pairs in G-Metric Spaces
Hussain, N.; Parvaneh, V.; Hoseini Ghoncheh, S. J.
2014-01-01
The aim of this paper is to present some coincidence and common fixed point results for generalized (ψ, φ)-contractive mappings using partially weakly G-α-admissibility in the setup of G-metric space. As an application of our results, periodic points of weakly contractive mappings are obtained. We also derive certain new coincidence point and common fixed point theorems in partially ordered G-metric spaces. Moreover, some examples are provided here to illustrate the usability of the obtained results. PMID:25202742
50 CFR 660.212 - Fixed gear fishery-prohibitions.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., Painted Cave, Anacapa Island, Carrington Point, Judith Rock, Skunk Point, Footprint, Gull Island, South... are specific to the limited entry fixed gear fisheries. General groundfish prohibitions are found at § 660.12, subpart C. In addition to the general groundfish prohibitions specified in § 660.12, subpart C...
L-fuzzy fixed points theorems for L-fuzzy mappings via βℱL-admissible pair.
Rashid, Maliha; Azam, Akbar; Mehmood, Nayyar
2014-01-01
We define the concept of βℱL-admissible for a pair of L-fuzzy mappings and establish the existence of common L-fuzzy fixed point theorem. Our result generalizes some useful results in the literature. We provide an example to support our result.
DOT National Transportation Integrated Search
1978-04-01
Volume 2 defines a new algorithm for the network equilibrium model that works in the space of path flows and is based on the theory of fixed point method. The goals of the study were broadly defined as the identification of aggregation practices and ...
NASA Astrophysics Data System (ADS)
Singh, Y. P.; Maas, H.; Edler, F.; Zaidi, Z. H.
1994-01-01
A set of resistance ratios (W) for platinum resistance thermometers was obtained at the triple point of Hg and the melting point of Ga in order to study their relationship. It was found that using measured values for one of the fixed points, a linear equation will predict the value of the other. These measurements also indicate that the fixed points of Hg and of Ga are inconsistent by about 1,5 mK in the sense that either the melting point of Ga or the triple point of Hg was assigned too high a value on the ITS-90.
Parameter estimation for slit-type scanning sensors
NASA Technical Reports Server (NTRS)
Fowler, J. W.; Rolfe, E. G.
1981-01-01
The Infrared Astronomical Satellite, scheduled for launch into a 900 km near-polar orbit in August 1982, will perform an infrared point source survey by scanning the sky with slit-type sensors. The description of position information is shown to require the use of a non-Gaussian random variable. Methods are described for deciding whether separate detections stem from a single common source, and a formulism is developed for the scan-to-scan problems of identifying multiple sightings of inertially fixed point sources for combining their individual measurements into a refined estimate. Several cases are given where the general theory yields results which are quite different from the corresponding Gaussian applications, showing that argument by Gaussian analogy would lead to error.
Fixed points of contractive mappings in b-metric-like spaces.
Hussain, Nawab; Roshan, Jamal Rezaei; Parvaneh, Vahid; Kadelburg, Zoran
2014-01-01
We discuss topological structure of b-metric-like spaces and demonstrate a fundamental lemma for the convergence of sequences. As an application we prove certain fixed point results in the setup of such spaces for different types of contractive mappings. Finally, some periodic point results in b-metric-like spaces are obtained. Two examples are presented in order to verify the effectiveness and applicability of our main results.
Simulation of design-unbiased point-to-particle sampling compared to alternatives on plantation rows
Thomas B. Lynch; David Hamlin; Mark J. Ducey
2016-01-01
Total quantities of tree attributes can be estimated in plantations by sampling on plantation rows using several methods. At random sample points on a row, either fixed row lengths or variable row lengths with a fixed number of sample trees can be assessed. Ratio of means or mean of ratios estimators can be developed for the fixed number of trees option but are not...
Husic, Samir; Izic, Senad; Matic, Srecko; Sukalo, Aziz
2015-01-01
Goal: The goal of the research was to determine the efficacy of a fixed combination of tramadol and paracetamol (acetaminophen) in the treatment of pain of patients with the advanced stage of cancer. Material and methods: A prospective study was conducted at the Center for Palliative Care, University Clinical Center Tuzla, Bosnia and Herzegovina, from January 1st to December 31st 2013. A total of 353 patients who were treated with a fixed combination of tramadol and acetaminophen (37.5 mg and 325 mg) at the initial dosage 3x1 tablet (112.5 mg tramadol and 975 mg acetaminophen) for pain intensity 4, up to 4x2 tablets (300 mg of tramadol and 2600 mg paracetamol) for pain intensity 7 and 8. If the patient during previous day has two or more pain episodes that required a “rescue dose” of tramadol, increased was the dose of fixed combination tramadol and acetaminophen to a maximum of 8 tablets daily (300 mg of tramadol and 2600 mg paracetamol). Statistical analysis was performed by biomedical software MedCalc for Windows version 9.4.2.0. The difference was considered significant for P<0.05. Results: The average duration of treatment with a fixed combination tramadol and acetaminophen was 57 days (13-330 days). Already after 24 hours of treatment the average pain score was significantly lower (p<0.0001) compared to the admission day [5.00 (4:00 to 8:00) during the first days versus 2.00 (1:00 to 7:00) during the second day of treatment]. The average dose of the fixed combination tramadol and acetaminophen tablets was 4.8 ± 1.8 (180 mg of tramadol and 1560 mg paracetamol). Side effects, in the treatment of pain with a fixed combination tramadol and acetaminophen, were found in 29.18% of patients, with a predominance of nausea and vomiting. Conclusion: Fixed combination of tramadol and acetaminophen can be used as an effective combination in the treatment of chronic cancer pain, with frequent dose evaluation and mild side effects. PMID:25870531
Husic, Samir; Izic, Senad; Matic, Srecko; Sukalo, Aziz
2015-02-01
The goal of the research was to determine the efficacy of a fixed combination of tramadol and paracetamol (acetaminophen) in the treatment of pain of patients with the advanced stage of cancer. A prospective study was conducted at the Center for Palliative Care, University Clinical Center Tuzla, Bosnia and Herzegovina, from January 1(st) to December 31(st) 2013. A total of 353 patients who were treated with a fixed combination of tramadol and acetaminophen (37.5 mg and 325 mg) at the initial dosage 3x1 tablet (112.5 mg tramadol and 975 mg acetaminophen) for pain intensity 4, up to 4x2 tablets (300 mg of tramadol and 2600 mg paracetamol) for pain intensity 7 and 8. If the patient during previous day has two or more pain episodes that required a "rescue dose" of tramadol, increased was the dose of fixed combination tramadol and acetaminophen to a maximum of 8 tablets daily (300 mg of tramadol and 2600 mg paracetamol). Statistical analysis was performed by biomedical software MedCalc for Windows version 9.4.2.0. The difference was considered significant for P<0.05. The average duration of treatment with a fixed combination tramadol and acetaminophen was 57 days (13-330 days). Already after 24 hours of treatment the average pain score was significantly lower (p<0.0001) compared to the admission day [5.00 (4:00 to 8:00) during the first days versus 2.00 (1:00 to 7:00) during the second day of treatment]. The average dose of the fixed combination tramadol and acetaminophen tablets was 4.8 ± 1.8 (180 mg of tramadol and 1560 mg paracetamol). Side effects, in the treatment of pain with a fixed combination tramadol and acetaminophen, were found in 29.18% of patients, with a predominance of nausea and vomiting. Fixed combination of tramadol and acetaminophen can be used as an effective combination in the treatment of chronic cancer pain, with frequent dose evaluation and mild side effects.
Efficacy and Safety of a Single-Pill Fixed-Dose Combination of Azilsartan and Amlodipine
Motozato, Kota; Miura, Shin-ichiro; Shiga, Yuhei; Kusumoto, Takaaki; Saku, Keijiro
2016-01-01
Background Guidelines for the management of hypertension recommend the use of drugs with different mechanisms of action in antihypertensive regimens that include single-pill fixed-dose combinations of medications. There is some controversy regarding which single-pill fixed-dose combinations of angiotensin II type 1 receptor blockers (ARBs) and calcium channel blockers (CCBs) are effective at reducing blood pressure (BP). Methods Forty hypertensive patients who were receiving a single-pill fixed-dose combination of valsartan 80 mg/day and amlodipine 5 mg/day or irbesartan 100 mg/day and amlodipine 5 mg/day were enrolled. They were randomly divided into two treatment groups, a group that changed to a single-pill fixed-dose combination of azilsartan 20 mg/day and amlodipine 5 mg/day (changeover group) and a group that continued to receive valsartan 80 mg/day and amlodipine 5 mg/day or irbesartan 100 mg/day and amlodipine 5 mg/day (control group), and treated for 16 weeks. Results There were no significant differences in systolic blood pressure (SBP), diastolic blood pressure (DBP) or pulse rate (PR) at 16 weeks between the control and changeover groups. In addition, there were no significant changes in biochemical parameters throughout the study period in both groups. Conclusion The ability of a single-pill fixed-dose combination of azilsartan and amlodipine to reduce BP may be comparable to that of a combination of valsartan and amlodipine or irbesartan and amlodipine. PMID:27829955
NASA Astrophysics Data System (ADS)
Pokhodun, A. I.; Ivanova, A. G.; Duysebayeva, K. K.; Ivanova, K. P.
2015-01-01
Regional comparison of type S thermocouples at the freezing points of zinc, aluminium and copper was initiated by COOMET TC1.1-10 (the technical committee of COOMET `Thermometry and thermal physics'). Three NMI take part in COOMET regional comparison: D I Mendeleev Institute for Metrology (VNIIM) (Russian Federation), National Scientific Centre (Institute of Metrology) (NSC IM, Ukraine), Republic State Enterprise (Kazakhstan Institute of Metrology) (KazInMetr, Republic of Kazakhstan). VNIIM (Russia) was chosen as the coordinator-pilot of the regional comparison. A star type comparison was used. The participants: KazInMetr and NSC IM constructed the type S thermocouples and calibrated them in three fixed points: zinc, aluminum and copper points, using methods of ITS-90 fixed point realizations. The thermocouples have been sent to VNIIM together with the results of the calibration at three fixed points, with the values of the inhomogeneity at temperature 200 °C and the uncertainty evaluations of the results. For calibration of thermocouples the same VNIIM fixed points cells were used. Participating laboratories repeated the calibration of thermocouples after its returning in zinc, aluminum and copper points to determine the stability of its results. In result of the comparison was to evaluate the equivalence of the type S thermocouples calibration in fixed points by NMIs to confirm corresponding lines of international website for NMI's Calibration and Measurement Capabilities (CMC). This paper is the final report of the comparison including analysis of the uncertainty of measurement results. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT WG-KC, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Clinical utility of azilsartan-chlorthalidone fixed combination in the management of hypertension.
Shuster, Jerrica E; Bleske, Barry E; Dorsch, Michael P
2012-01-01
Azilsartan-chlorthalidone fixed combination is a new drug in the management of hypertension. Azilsartan has been shown to have greater blood pressure-lowering effects than other angiotensin-receptor blockers (ARBs), and the debate regarding the superiority of chlorthalidone over hydrochlorothiazide has been ongoing for years. The combination is unique because it is the first to partner an ARB with this, possibly more effective, diuretic. This review will address trials involving both components of this drug, as well as phase III trials involving the fixed-combination product. The article will also discuss the benefit of combination therapy in the treatment of hypertension.
Clinical utility of azilsartan–chlorthalidone fixed combination in the management of hypertension
Shuster, Jerrica E; Bleske, Barry E; Dorsch, Michael P
2012-01-01
Azilsartan–chlorthalidone fixed combination is a new drug in the management of hypertension. Azilsartan has been shown to have greater blood pressure-lowering effects than other angiotensin-receptor blockers (ARBs), and the debate regarding the superiority of chlorthalidone over hydrochlorothiazide has been ongoing for years. The combination is unique because it is the first to partner an ARB with this, possibly more effective, diuretic. This review will address trials involving both components of this drug, as well as phase III trials involving the fixed-combination product. The article will also discuss the benefit of combination therapy in the treatment of hypertension. PMID:22745562
NASA Astrophysics Data System (ADS)
Nikitin, S. A.; Polezhaev, V. I.; Sazonov, V. V.
2001-03-01
The problem of the interpretation of measurements made by means of a convection sensor is considered. The sensor is a cubic chamber filled by a viscous fluid (gas). Fixed and unequal temperatures are maintained on two opposite sides of the cube; the other sides are perfect heat conductors. Two differential thermocouples are placed inside the chamber to measure the temperature difference at two pairs of fixed points. The sensor is mounted aboard the Earth's satellite. Mathematical models of various degrees of complexity are proposed which describe processes of heat and mass transfer under the action of a quasistatic component of microaccelerations. The results of mathematical simulation of the data of sensor thermocouples presenting a response to the real quasistatic component of microaccelerations which took place aboard the Mirstation are given. It is shown that under usual conditions of an orbital mission the sensor presents a linear low-frequency filter. By combining the data of several identical sensors, tightly arranged and oriented in a certain way, it is possible to measure low-frequency components of the angular acceleration of the satellite and linear microaccelerations at the point of the sensor position.
Research in the design of high-performance reconfigurable systems
NASA Technical Reports Server (NTRS)
Slotnick, D. L.; Mcewan, S. D.; Spry, A. J.
1984-01-01
An initial design for the Bit Processor (BP) referred to in prior reports as the Processing Element or PE has been completed. Eight BP's, together with their supporting random-access memory, a 64 k x 9 ROM to perform addition, routing logic, and some additional logic, constitute the components of a single stage. An initial stage design is given. Stages may be combined to perform high-speed fixed or floating point arithmetic. Stages can be configured into a range of arithmetic modules that includes bit-serial one or two-dimensional arrays; one or two dimensional arrays fixed or floating point processors; and specialized uniprocessors, such as long-word arithmetic units. One to eight BP's represent a likely initial chip level. The Stage would then correspond to a first-level pluggable module. As both this project and VLSI CAD/CAM progress, however, it is expected that the chip level would migrate upward to the stage and, perhaps, ultimately the box level. The BP RAM, consisting of two banks, holds only operands and indices. Programs are at the box (high-level function) and system level. At the system level initial effort has been concentrated on specifying the tools needed to evaluate design alternatives.
Treatment of Combined Spinal Deformity in Patient with Ollier Disease and Abnormal Vertebrae
Ryabykh, S. О.; Gubin, A. V.; Prudnikova, О. G.; Kobyzev, А. Е.
2012-01-01
We report staged treatment of severe combined spinal deformity in an 11-year-old patient with Ollier disease and abnormal cervical vertebra. Combined scoliosis with systemic pathology and abnormal vertebrae is a rare condition and features atypical deformity location and rapid progression rate and frequently involves the rib cage and pelvis, disturbing the function of chest organs and skeleton. Progressive deformity resulted in cachexia and acute respiratory failure. A halo-pelvic distraction device assembled of Ilizarov components was employed for a staged surgical treatment performed for lifesaving indications. After vital functions stabilized, the scoliosis curve of the cervical spine was corrected and fixed with a hybrid system of transpedicular supporting points, connecting rods, and connectors that provided staged distraction during growth. The treatment showed good functional and cosmetic result. PMID:24436859
The four fixed points of scale invariant single field cosmological models
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xue, BingKan, E-mail: bxue@princeton.edu
2012-10-01
We introduce a new set of flow parameters to describe the time dependence of the equation of state and the speed of sound in single field cosmological models. A scale invariant power spectrum is produced if these flow parameters satisfy specific dynamical equations. We analyze the flow of these parameters and find four types of fixed points that encompass all known single field models. Moreover, near each fixed point we uncover new models where the scale invariance of the power spectrum relies on having simultaneously time varying speed of sound and equation of state. We describe several distinctive new modelsmore » and discuss constraints from strong coupling and superluminality.« less
NASA Astrophysics Data System (ADS)
Taylor, Marika; Woodhead, William
2017-12-01
The F theorem states that, for a unitary three dimensional quantum field theory, the F quantity defined in terms of the partition function on a three sphere is positive, stationary at fixed point and decreases monotonically along a renormalization group flow. We construct holographic renormalization group flows corresponding to relevant deformations of three-dimensional conformal field theories on spheres, working to quadratic order in the source. For these renormalization group flows, the F quantity at the IR fixed point is always less than F at the UV fixed point, but F increases along the RG flow for deformations by operators of dimension between 3/2 and 5/2. Therefore the strongest version of the F theorem is in general violated.
Bilateral Comparison Between NIM and NMC Over the Temperature Range from 83.8058 K to 692.677 K
NASA Astrophysics Data System (ADS)
Sun, Jianping; Ye, Shaochun; Kho, Haoyuan; Zhang, Jintao; Wang, Li
2015-08-01
A bilateral comparison of local realization of the International Temperature Scale of 1990 between the National Institute of Metrology (NIM) and National Metrology Centre (NMC) was carried out over the temperature range from 83.8058 K to 692.677 K. It involved six fixed points including the argon triple point, the mercury triple point, the triple point of water, the melting point of gallium, the freezing point of tin, and the freezing point of zinc. In 2009, NMC asked NIM to participate in a bilateral comparison to link the NMC results to the Consultative Committee for Thermometry Key Comparison 3 (CCT-K3) and facilitate the NMC's calibration and measurement capabilities submission. This comparison was agreed by NIM and Asia Pacific Metrology Programme in 2009, and registered in the Key Comparison Database in 2010 as CCT-K3.2. NMC supplied two fused silica sheath standard platinum resistance thermometers (SPRTs) as traveling standards. One of them was used at the Ga, Sn, and Zn fixed points, while the other one was used at the Ar and Hg fixed points. NMC measured them before and after NIM measured them. During the comparison, a criterion for the SPRT was set as the stability at the triple point of water to be less than 0.3 mK. The results for both laboratories are summarized. A proposal for linking the NMC's comparison results to CCT-K3 is presented. The difference between NMC and NIM and the difference between NMC and the CCT-K3 average reference value using NIM as a link are reported with expanded uncertainties at each measured fixed point.
NASA Astrophysics Data System (ADS)
Huber, A.; Chankin, A. V.
2017-06-01
A simple two-point representation of the tokamak scrape-off layer (SOL) in the conduction limited regime, based on the parallel and perpendicular energy balance equations in combination with the heat flux width predicted by a heuristic drift-based model, was used to derive a scaling for the cross-field thermal diffusivity {χ }\\perp . For fixed plasma shape and neglecting weak power dependence indexes 1/8, the scaling {χ }\\perp \\propto {P}{{S}{{O}}{{L}}}/(n{B}θ {R}2) is derived.
NASA Astrophysics Data System (ADS)
Li, Husheng; Betz, Sharon M.; Poor, H. Vincent
2007-05-01
This paper examines the performance of decision feedback based iterative channel estimation and multiuser detection in channel coded aperiodic DS-CDMA systems operating over multipath fading channels. First, explicit expressions describing the performance of channel estimation and parallel interference cancellation based multiuser detection are developed. These results are then combined to characterize the evolution of the performance of a system that iterates among channel estimation, multiuser detection and channel decoding. Sufficient conditions for convergence of this system to a unique fixed point are developed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Y; Zhang, J; Hu, Q
2014-06-01
Purpose: To investigate the possibility of applying optimized scanning protocols for pediatric CT simulation by quantifying the dosimetric inaccuracy introduced by using a fixed HU to density conversion. Methods: The images of a CIRS electron density reference phantom (Model 062) were acquired by a Siemens CT simulator (Sensation Open) using the following settings of tube voltage and beam current: 120 kV/190mA (the reference protocol used to calibrate CT for our treatment planning system (TPS)); Fixed 190mA combined with all available kV: 80, 100, and 140; fixed 120 kV and various current from 37 to 444 mA (scanner extremes) with intervalmore » of 30 mA. To avoid the HU uncertainty of point sampling in the various inserts of known electron densities, the mean CT numbers of the central cylindrical volume were calculated using DICOMan software. The doses per 100 MU to the reference point (SAD=100cm, Depth=10cm, Field=10X10cm, 6MV photon beam) in a virtual cubic phantom (30X30X30cm) were calculated using Eclipse TPS (calculation model: AcurosXB-11031) by assigning the CT numbers to HU of typical materials acquired by various protocols. Results: For the inserts of densities less than muscle, CT number fluctuations of all protocols were within the tolerance of 10 HU as accepted by AAPM-TG66. For more condensed materials, fixed kV yielded stable HU with any mA combination where largest disparities were found in 1750mg/cc insert: HU{sub reference}=1801(106.6cGy), HU{sub minimum}=1799 (106.6cGy, error{sub dose}=0.00%), HU{sub maximum}=1815 (106.8cGy, error{sub dose}=0.19%). Yet greater disagreements were observed with increasing density when kV was modified: HU{sub minimum}=1646 (104.5cGy, error{sub dose}=- 1.97%), HU{sub maximum}=2487 (116.4cGy, error{sub dose}=9.19%) in 1750mg/cc insert. Conclusion: Without affecting treatment dose calculation, personalized mA optimization of CT simulator can be conducted by fixing kV for a better cost-effectiveness of imaging dose and quality especially for children. Unless recalibrated, kV should be constant for all anatomical sites if diagnostic CT scanner is used as a simulator. This work was partially supported by Capital Medical Development Scientific Research Fund of China.« less
Fixed-Time Schedule Effects in Combination with Response-Dependent Schedules
ERIC Educational Resources Information Center
Borrero, John C.; Bartels-Meints, Jamie A.; Sy, Jolene R.; Francisco, Monica T.
2011-01-01
We evaluated the effects of fixed-interval (FI), fixed-time (FT), and conjoint (combined) FI FT reinforcement schedules on the responding of 3 adults who had been diagnosed with schizophrenia. Responding on vocational tasks decreased for 2 of 3 participants under FT alone relative to FI alone. Responding under FI FT resulted in response…
Fixed Points of Contractive Mappings in b-Metric-Like Spaces
Hussain, Nawab; Roshan, Jamal Rezaei
2014-01-01
We discuss topological structure of b-metric-like spaces and demonstrate a fundamental lemma for the convergence of sequences. As an application we prove certain fixed point results in the setup of such spaces for different types of contractive mappings. Finally, some periodic point results in b-metric-like spaces are obtained. Two examples are presented in order to verify the effectiveness and applicability of our main results. PMID:25143980
ISO(4,1) symmetry in the EFT of inflation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Creminelli, Paolo; Emami, Razieh; Simonović, Marko
In DBI inflation the cubic action is a particular linear combination of the two, otherwise independent, cubic operators π-dot {sup 3} and π-dot (∂{sub i}π){sup 2}. We show that in the Effective Field Theory (EFT) of inflation this is a consequence of an approximate 5D Poincar and apos;e symmetry, ISO(4,1), non-linearly realized by the Goldstone π. This symmetry uniquely fixes, at lowest order in derivatives, all correlation functions in terms of the speed of sound c{sub s}. In the limit c{sub s} → 1, the ISO(4,1) symmetry reduces to the Galilean symmetry acting on π. On the other hand, wemore » point out that the non-linear realization of SO(4,2), the isometry group of 5D AdS space, does not fix the cubic action in terms of c{sub s}.« less
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Special showing for renewal of common carrier... COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES Common Carrier Fixed Point-to-Point Microwave Service § 101.705 Special showing for renewal of common carrier station...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Operation of internal transmitter control systems through licensed fixed control points. 90.473 Section 90.473 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control...
L-Fuzzy Fixed Points Theorems for L-Fuzzy Mappings via β ℱL-Admissible Pair
Rashid, Maliha; Azam, Akbar
2014-01-01
We define the concept of β ℱL-admissible for a pair of L-fuzzy mappings and establish the existence of common L-fuzzy fixed point theorem. Our result generalizes some useful results in the literature. We provide an example to support our result. PMID:24688441
ASIC For Complex Fixed-Point Arithmetic
NASA Technical Reports Server (NTRS)
Petilli, Stephen G.; Grimm, Michael J.; Olson, Erlend M.
1995-01-01
Application-specific integrated circuit (ASIC) performs 24-bit, fixed-point arithmetic operations on arrays of complex-valued input data. High-performance, wide-band arithmetic logic unit (ALU) designed for use in computing fast Fourier transforms (FFTs) and for performing ditigal filtering functions. Other applications include general computations involved in analysis of spectra and digital signal processing.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 5 2013-10-01 2013-10-01 false Operation of internal transmitter control systems through licensed fixed control points. 90.473 Section 90.473 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Operation of internal transmitter control systems through licensed fixed control points. 90.473 Section 90.473 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false Operation of internal transmitter control systems through licensed fixed control points. 90.473 Section 90.473 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false Operation of internal transmitter control systems through licensed fixed control points. 90.473 Section 90.473 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND MOBILE RADIO SERVICES Transmitter Control Internal Transmitter Control...
Geometry in a dynamical system without space: Hyperbolic Geometry in Kuramoto Oscillator Systems
NASA Astrophysics Data System (ADS)
Engelbrecht, Jan; Chen, Bolun; Mirollo, Renato
Kuramoto oscillator networks have the special property that their time evolution is constrained to lie on 3D orbits of the Möbius group acting on the N-fold torus TN which explains the N - 3 constants of motion discovered by Watanabe and Strogatz. The dynamics for phase models can be further reduced to 2D invariant sets in T N - 1 which have a natural geometry equivalent to the unit disk Δ with hyperbolic metric. We show that the classic Kuramoto model with order parameter Z1 (the first moment of the oscillator configuration) is a gradient flow in this metric with a unique fixed point on each generic 2D invariant set, corresponding to the hyperbolic barycenter of an oscillator configuration. This gradient property makes the dynamics especially easy to analyze. We exhibit several new families of Kuramoto oscillator models which reduce to gradient flows in this metric; some of these have a richer fixed point structure including non-hyperbolic fixed points associated with fixed point bifurcations. Work Supported by NSF DMS 1413020.
NASA Astrophysics Data System (ADS)
Palenčár, Rudolf; Sopkuliak, Peter; Palenčár, Jakub; Ďuriš, Stanislav; Suroviak, Emil; Halaj, Martin
2017-06-01
Evaluation of uncertainties of the temperature measurement by standard platinum resistance thermometer calibrated at the defining fixed points according to ITS-90 is a problem that can be solved in different ways. The paper presents a procedure based on the propagation of distributions using the Monte Carlo method. The procedure employs generation of pseudo-random numbers for the input variables of resistances at the defining fixed points, supposing the multivariate Gaussian distribution for input quantities. This allows taking into account the correlations among resistances at the defining fixed points. Assumption of Gaussian probability density function is acceptable, with respect to the several sources of uncertainties of resistances. In the case of uncorrelated resistances at the defining fixed points, the method is applicable to any probability density function. Validation of the law of propagation of uncertainty using the Monte Carlo method is presented on the example of specific data for 25 Ω standard platinum resistance thermometer in the temperature range from 0 to 660 °C. Using this example, we demonstrate suitability of the method by validation of its results.
Brückner, Hans-Peter; Spindeldreier, Christian; Blume, Holger
2013-01-01
A common approach for high accuracy sensor fusion based on 9D inertial measurement unit data is Kalman filtering. State of the art floating-point filter algorithms differ in their computational complexity nevertheless, real-time operation on a low-power microcontroller at high sampling rates is not possible. This work presents algorithmic modifications to reduce the computational demands of a two-step minimum order Kalman filter. Furthermore, the required bit-width of a fixed-point filter version is explored. For evaluation real-world data captured using an Xsens MTx inertial sensor is used. Changes in computational latency and orientation estimation accuracy due to the proposed algorithmic modifications and fixed-point number representation are evaluated in detail on a variety of processing platforms enabling on-board processing on wearable sensor platforms.
Chen, I L; Chen, J T; Kuo, S R; Liang, M T
2001-03-01
Integral equation methods have been widely used to solve interior eigenproblems and exterior acoustic problems (radiation and scattering). It was recently found that the real-part boundary element method (BEM) for the interior problem results in spurious eigensolutions if the singular (UT) or the hypersingular (LM) equation is used alone. The real-part BEM results in spurious solutions for interior problems in a similar way that the singular integral equation (UT method) results in fictitious solutions for the exterior problem. To solve this problem, a Combined Helmholtz Exterior integral Equation Formulation method (CHEEF) is proposed. Based on the CHEEF method, the spurious solutions can be filtered out if additional constraints from the exterior points are chosen carefully. Finally, two examples for the eigensolutions of circular and rectangular cavities are considered. The optimum numbers and proper positions for selecting the points in the exterior domain are analytically studied. Also, numerical experiments were designed to verify the analytical results. It is worth pointing out that the nodal line of radiation mode of a circle can be rotated due to symmetry, while the nodal line of the rectangular is on a fixed position.
Nakakura, Shunsuke; Tabuchi, Hitoshi; Baba, Yukio; Maruiwa, Futoshi; Ando, Nobuko; Kanamoto, Takashi; Kiuchi, Yoshiaki
2012-01-01
Objective To compare the safety and effectiveness of fixed-combination regimes (latanoprost– timolol and brinzolamide 1% compared to dorzolamide 1%/timolol and latanoprost) in open-angle glaucoma patients after switching from a combination of three topical antiglaucoma eye drops. Methods We conducted an open, randomized 12-week multicenter prospective study. We randomly allocated 39 patients who had been treated with three antiglaucoma eye drops (prostaglandin F2α analogues plus beta-blockers and carbonic anhydrase inhibitors) into two groups. Group A (n = 20) were treated with latanoprost–timolol and brinzolamide 1% therapy and Group B (n = 16) were treated with dorzolamide 1%/timolol and latanoprost. Thirty-six patients completed all 12 weeks of this study. The major clinical parameters measured were intraocular pressure (IOP), conjunctive hyperemia, superficial punctate keratopathy and hyperpigmentation of eyelid at baseline, 4, and 12 weeks. Additionally noted were adverse events and patient preferences, measured using a questionnaire at study initiation and at 12 weeks. Results At baseline, IOPs were (Group A: 14.1 ± 2.9 mmHg, B: 14.5 ± 2.9 mmHg; P = 0.658), (Group A: 13.8 ± 2.6 mmHg, B: 14.3 ± 2.8 mmHg; P = 0.715) at 4 weeks, and (Group A: 14.1 ± 2.7 mmHg, B: 14.2 ± 2.7 mmHg; P = 0.538) at 12 weeks. Among the groups, there was no significant difference at any time point after baseline (P = 0.923, 0.951, respectively). All adverse events were not remarkably different after therapy. In regards to patient preference before and after switching therapy, 10 patients (50%) in Group A and 10 patients (63%) in Group B preferred using fixed-combination eye drop therapy. Conclusions Effectiveness and safety were maintained in both groups after switching therapy. Overall, patients generally preferred using a fixed-combination therapy. PMID:22419858
Mahu, Ştefania Corina; Hăncianu, Monica; Agoroaei, Luminiţa; Grigoriu, Ioana Cezara; Strugaru, Anca Monica; Butnaru, Elena
2015-01-01
Hypertension is one of the most common causes of death, a complex and incompletely controlled disease for millions of patients. Metoprolol, bisoprolol, nebivolol and atenolol are selective beta-blockers frequently used in the management of arterial hypertension, alone or in fixed combination with other substances. This study presents the most used analytical methods for simultaneous determination in biological fluids of fixed combinations containing selective beta-blockers. Articles in Pub-Med, Science Direct and Wiley Journals databases published between years 2004-2014 were reviewed. Methods such as liquid chromatography--mass spectrometry--mass spectrometry (LC-MS/MS), high performance liquid chromatography (HPLC) or high performance liquid chromatography--mass spectrometry (HPLC-MS) were used for determination of fixed combination with beta-blockers in human plasma, rat plasma and human breast milk. LC-MS/MS method was used for simultaneous determination of fixed combinations of metoprolol with simvastatin, hydrochlorothiazide or ramipril, combinations of nebivolol and valsartan, or atenolol and amlodipine. Biological samples were processed by protein precipitation techniques or by liquid-liquid extraction. For the determination of fixed dose combinations of felodipine and metoprolol in rat plasma liquid chromatography--electrospray ionization--mass spectrometry (LC-ESI-MS/MS) was applied, using phenacetin as internal standard. HPLC-MS method was applied for the determination of bisoprolol and hydrochlorothiazide in human plasma. For the determination of atenolol and chlorthalidone from human breast milk and human plasma the HPLC method was used. The analytical methods were validated according to the specialized guidelines, and were applied to biological samples, thing that confirms the permanent concern of researchers in this field.
Song, Hyung Keun; Yoo, Je Hyun; Byun, Young Soo; Yang, Kyu Hyun
2014-05-01
Among patients over 50 years of age, separate vertical wiring alone may be insufficient for fixation of fractures of the inferior pole of the patella. Therefore, mechanical and clinical studies were performed in patients over the age of 50 to test the strength of augmentation of separate vertical wiring with cerclage wire (i.e., combined technique). Multiple osteotomies were performed to create four-part fractures in the inferior poles of eight pairs of cadaveric patellae. One patella from each pair was fixed with the separate wiring technique, while the other patella was fixed with a combined technique. The ultimate load to failure and stiffness of the fixation were subsequently measured. In a clinical study of 21 patients (average age of 64 years), comminuted fractures of the inferior pole of the patellae were treated using the combined technique. Operative parameters were recorded from which post-operative outcomes were evaluated. For cadaveric patellae, whose mean age was 69 years, the mean ultimate loads to failure for the separate vertical wiring technique and the combined technique were 216.4±72.4 N and 324.9±50.6 N, respectively (p=0.012). The mean stiffness for the separate vertical wiring technique and the combined technique was 241.1±68.5 N/mm and 340.8±45.3 N/mm, respectively (p=0.012). In the clinical study, the mean clinical score at final follow-up was 28.1 points. Augmentation of separate vertical wiring with cerclage wire provides enough strength for protected early exercise of the knee joint and uneventful healing.
FixO3 project results, legacy and module migration to EMSO
NASA Astrophysics Data System (ADS)
Lampitt, Richard
2017-04-01
The fixed point open ocean observatory network (FixO3) project is an international project aimed at integrating in a single network all fixed point open ocean observatories operated by European organisations and to harmonise and coordinate technological, procedural and data management across the stations. The project is running for four years since September 2013 with 29 partners across Europe and a budget of 7M Euros and is now coming to its final phase. In contrast to several past programmes, the opportunity has arisen to ensure that many of the project achievements can migrate into the newly formed European Multidisciplinary Seafloor and water column Observatory (EMSO) research infrastructure. The final phase of the project will focus on developing a strategy to transfer the results in an efficient way to maintain their relevance and maximise their use. In this presentation, we will highlight the significant achievements of FixO3 over the past three years focussing on the modules which will be transferred to EMSO in the coming 9 months. These include: 1. Handbook of best practices for operating fixed point observatories 2. Metadata catalogue 3. Earth Virtual Observatory (EarthVO) for data visualisation and comparison 4. Open Ocean Observatory Yellow Pages (O3YP) 5. Training material for hardware, data and data products used
Emanuele, Enzo; Bertona, Marco; Biagi, Marco
2017-02-01
Polypodium leucotomos extract is a commonly used systemic photoprotective agent. In an exploratory fashion, the current study aimed to compare the effects of oral supplementation with a fixed Polypodium leucotomos/pomegranate combination (PPmix®) versus Polypodium leucotomos alone (Fernblock®) on skin biophysical parameters of Caucasian adults. Forty healthy adult volunteers (20 males and 20 females; mean age: 37.2±5.5 years) were randomized in a 1:1 fashion to a fixed Polypodium leucotomos/pomegranate combination (480 mg/day; n=20) or Polypodium leucotomos alone (480 mg/day; n=20) for 3 months. Six skin biophysical parameters (skin sebum content, hydration, transepidermal water loss [TEWL], erythema index, melanin index, and elasticity) were measured at baseline and after 3 months by personnel blinded to participant allocation. At the end of the study, hydration and elasticity were significantly improved and TEWL was reduced in both groups, without significant intergroup differences. The erythema index was decreased by both treatments, although the fixed Polypodium leucotomos/pomegranate combination was significantly more effective. Finally, melanin index and skin sebum content were reduced by the fixed Polypodium leucotomos/pomegranate combination, whereas Polypodium leucotomos alone did not affect them. Our results suggest that a fixed Polypodium leucotomos/pomegranate combination provides a greater improvement of skin biophysical parameters compared to Polypodium leucotomos alone in adult Caucasians. Our findings may have implications for optimizing systemic skin photoprotection and beautification strategies.
Raveendran, Rajkumar Nallour; Babu, Raiju J; Hess, Robert F; Bobier, William R
2014-03-01
To test the hypothesis that fixational stability of the amblyopic eye in strabismics will improve when viewing provides both bifoveal fixation and reduced inter-ocular suppression by reducing the contrast to the fellow eye. Seven strabismic amblyopes (Age: 29.2 ± 9 years; five esotropes and two exotropes) showing clinical characteristics of central suppression were recruited. Interocular suppression was measured by a global motion task. For each participant, a balance point was determined which defined contrast levels for each eye where binocular combination was optimal (interocular suppression minimal). When the balance point could not be determined, this participant was excluded. Bifoveal fixation was established by ocular alignment using a haploscope. Participants dichoptically viewed similar targets (a cross of 2.3° surrounded by a square of 11.3°) at 40 cm. Target contrasts presented to each eye were either high contrast (100% to both eyes) or balanced contrast (attenuated contrast in the fellow fixing eye). Fixation stability was measured over a 5 min period and quantified using bivariate contour ellipse areas in four different binocular conditions; unaligned/high contrast, unaligned/balance point, aligned/high contrast and aligned/balance point. Fixation stability was also measured in six control subjects (Age: 25.3 ± 4 years). Bifoveal fixation in the strabismics was transient (58.15 ± 15.7 s). Accordingly, fixational stability was analysed over the first 30 s using repeated measures anova. Post hoc analysis revealed that for the amblyopic subjects, the fixational stability of the amblyopic eye was significantly improved in aligned/high contrast (p = 0.01) and aligned/balance point (p < 0.01) conditions. Fixational stability of the fellow fixing eye was not different statistically across conditions. Bivariate contour ellipse areas of the amblyopic and fellow fixing eyes were therefore averaged for each amblyope in the four conditions and compared with normals. This averaged bivariate contour ellipse area was significantly greater (reduced fixational stability, p = 0.04) in amblyopes compared to controls except in the case of aligned and balanced contrast (aligned/balance point, p = 0.19). Fixation stability in the amblyopic eye appears to improve with bifoveal fixation and reduced interocular suppression. However, once initiated, bifoveal fixation is transient with the strabismic eye drifting away from foveal alignment, thereby increasing the angle of strabismus. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.
A Hybrid Common Fixed Point Theorem under Certain Recent Properties
Imdad, Mohammad
2014-01-01
We prove a common fixed point theorem for a hybrid pair of occasionally coincidentally idempotent mappings via common limit range property. Our result improves some results from the existing literature, especially the ones contained in Sintunavarat and Kumam (2009). Some illustrative and interesting examples to highlight the realized improvements are also furnished. PMID:24592191
Alignment Solution for CT Image Reconstruction using Fixed Point and Virtual Rotation Axis.
Jun, Kyungtaek; Yoon, Seokhwan
2017-01-25
Since X-ray tomography is now widely adopted in many different areas, it becomes more crucial to find a robust routine of handling tomographic data to get better quality of reconstructions. Though there are several existing techniques, it seems helpful to have a more automated method to remove the possible errors that hinder clearer image reconstruction. Here, we proposed an alternative method and new algorithm using the sinogram and the fixed point. An advanced physical concept of Center of Attenuation (CA) was also introduced to figure out how this fixed point is applied to the reconstruction of image having errors we categorized in this article. Our technique showed a promising performance in restoring images having translation and vertical tilt errors.
Symmetry-breaking oscillations in membrane optomechanics
NASA Astrophysics Data System (ADS)
Wurl, C.; Alvermann, A.; Fehske, H.
2016-12-01
We study the classical dynamics of a membrane inside a cavity in the situation where this optomechanical system possesses a reflection symmetry. Symmetry breaking occurs through supercritical and subcritical pitchfork bifurcations of the static fixed-point solutions. Both bifurcations can be observed through variation of the laser-cavity detuning, which gives rise to a boomerang-like fixed-point pattern with hysteresis. The symmetry-breaking fixed points evolve into self-sustained oscillations when the laser intensity is increased. In addition to the analysis of the accompanying Hopf bifurcations we describe these oscillations at finite amplitudes with an ansatz that fully accounts for the frequency shift relative to the natural membrane frequency. We complete our study by following the route to chaos for the membrane dynamics.
A 640-MHz 32-megachannel real-time polyphase-FFT spectrum analyzer
NASA Technical Reports Server (NTRS)
Zimmerman, G. A.; Garyantes, M. F.; Grimm, M. J.; Charny, B.
1991-01-01
A polyphase fast Fourier transform (FFT) spectrum analyzer being designed for NASA's Search for Extraterrestrial Intelligence (SETI) Sky Survey at the Jet Propulsion Laboratory is described. By replacing the time domain multiplicative window preprocessing with polyphase filter processing, much of the processing loss of windowed FFTs can be eliminated. Polyphase coefficient memory costs are minimized by effective use of run length compression. Finite word length effects are analyzed, producing a balanced system with 8 bit inputs, 16 bit fixed point polyphase arithmetic, and 24 bit fixed point FFT arithmetic. Fixed point renormalization midway through the computation is seen to be naturally accommodated by the matrix FFT algorithm proposed. Simulation results validate the finite word length arithmetic analysis and the renormalization technique.
[Treatment of calcaneal avulsion fractures with twinfix suture anchors fixation].
Zhao, Bin-xiu; Wang, Kun-zheng; Wang, Chun-sheng; Xie, Yue; Dai, Zhi-tang; Liu, Gang; Liu, Wei-dong
2011-06-01
For the calcaneal avulsion fracture, the current method is more commonly used screws or Kirschner wire to fix fracture fragment. This article intended to explore the feasibility and clinical efficacy for the treatment of avulsion fractures with TwinFix suture anchors. From July 2007 to November 2010, 21 patients were reviewed, including 15 males and 6 females, ranging in age from 49 to 65 years,with a mean of 58.7 years. Twelve patients had nodules in the right heel and 9 patients had nodules in the left heel. All the patients had closed fractures. The typical preoperative symptoms of the patients included pain in the upper heel and weak in heel lift. Body examination results: palpable sense of bone rubbing in the back of the heel, and swelling in the heel. Surgery treatment with TwinFix suture anchors performed as follows : to fix TwinFix suture anchors into the calcaneal body, then to drill the fracture block, to make the double strand suture through the fracture holes, to knot the suture eachother to fix the block, and to use stitch to fix the remaining suture in the Achilles tendon in order to improve the block fixation. The criteria of the AOFAS Foot and Ankle Surgery by the United States Association of ankle-rear foot functional recovery was used to evaluate the Achilles tendon. Total average score was (95.5 +/- 3.12) points, including pain items of(38.5 +/- 2.18) points,the average score of functional items of (49.5 +/- 3.09) points,and power lines of 10 points in all patients. Twenty-one patients got an excellent result, 16 good and 5 poor. The methods of treatment for the calcaneal avulsion fractures with TwinFix suture anchors is a simple operation, and have excellent clinical effect, which is worthy of promotion.
Tympanic thermometer performance validation by use of a body-temperature fixed point blackbody
NASA Astrophysics Data System (ADS)
Machin, Graham; Simpson, Robert
2003-04-01
The use of infrared tympanic thermometers within the medical community (and more generically in the public domain) has recently grown rapidly, displacing more traditional forms of thermometry such as mercury-in-glass. Besides the obvious health concerns over mercury the increase in the use of tympanic thermometers is related to a number of factors such as their speed and relatively non-invasive method of operation. The calibration and testing of such devices is covered by a number of international standards (ASTM1, prEN2, JIS3) which specify the design of calibration blackbodies. However these calibration sources are impractical for day-to-day in-situ validation purposes. In addition several studies (e.g. Modell et al4, Craig et al5) have thrown doubt on the accuracy of tympanic thermometers in clinical use. With this in mind the NPL is developing a practical, portable and robust primary reference fixed point source for tympanic thermometer validation. The aim of this simple device is to give the clinician a rapid way of validating the performance of their tympanic thermometer, enabling the detection of mal-functioning thermometers and giving confidence in the measurement to the clinician (and patient!) at point of use. The reference fixed point operates at a temperature of 36.3 °C (97.3 °F) with a repeatability of approximately +/- 20 mK. The fixed-point design has taken into consideration the optical characteristics of tympanic thermometers enabling wide-angled field of view devices to be successfully tested. The overall uncertainty of the device is estimated to be is less than 0.1°C. The paper gives a description of the fixed point, its design and construction as well as the results to date of validation tests.
Kim, Mi-Kyeong; Lee, Sook Young; Park, Hae-Sim; Yoon, Ho Joo; Kim, Sang-Ha; Cho, Young Joo; Yoo, Kwang-Ha; Lee, Soo-Keol; Kim, Hee-Kyoo; Park, Jung-Won; Park, Heung-Woo; Chung, Jin-Hong; Choi, Byoung Whui; Lee, Byung-Jae; Chang, Yoon-Seok; Jo, Eun-Jung; Lee, Sang-Yeub; Cho, You Sook; Jee, Young-Koo; Lee, Jong-Myung; Jung, Jina; Park, Choon-Sik
2018-06-24
The aim of this study was to evaluate the efficacy and safety of a fixed-dose combination of montelukast and levocetirizine in patients with perennial allergic rhinitis with mild to moderate asthma compared with the efficacy and safety of montelukast alone. This study was a 4-week, randomized, multicenter, double-blind, Phase III trial. After a 1-week placebo run-in period, the subjects were randomized to receive montelukast (10mg/day, n = 112) or montelukast (10 mg/day)/levocetirizine (5 mg/day) (n = 116) treatment for 4 weeks. The primary efficacy end point was mean daytime nasal symptom score. Other efficacy end points included mean nighttime nasal symptom score, mean composite symptom score, overall assessment of allergic rhinitis by both subjects and physicians, forced expiratory volume in 1 second (FEV 1 ), forced vital capacity (FVC), FEV 1 /FVC, asthma control test score, and the frequency of rescue medication used during the treatment period. Of 333 patients screened for this study, 228 eligible patients were randomized to treatment. The mean (SD) age of patients was 43.32 (15.02) years, and two thirds of subjects were female (66.67%). The demographic characteristics were similar between the treatment groups. Compared with the montelukast group, the montelukast/levocetirizine group reported significant reductions in mean daytime nasal symptom score (least squares mean [SE] of combination vs montelukast, -0.98 [0.06] vs -0.81 [0.06]; P = 0.045). For all other allergic rhinitis efficacy end points, the montelukast/levocetirizine group showed greater improvement than the montelukast group. Similar results were observed in overall assessment scores and in FEV 1 , FVC, FEV 1 /FVC, and asthma control test score changes from baseline for the 2 treatment groups. Montelukast/levocetirizine was well tolerated, and the safety profile was similar to that observed in the montelukast group. The fixed-dose combination of montelukast and levocetirizine was effective and safe in treating perennial allergic rhinitis in patients with asthma compared with montelukast alone. ClinicalTrials.gov identifier: NCT02552667. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
Mehić, Bakir
2007-01-01
There is the question about the role of fixed combination of inhalatory corticosteroids and long acting β2 agonists in the treatment of patients admitted in hospital due to AECOPD. The objective of this study is to determine the frequency of etiologic factors of AECOPD, to research the length of recovery time and the time free from exacerbation due to AECOPD at the patients treated with fixed combination inhalers containing F/S versus patients who were not treated with this combination. This is retrospective-prospective, randomized, clinical study with a sample size of 70 patients who admitted to hospital due to AECOPD type I or II. Patients are randomized in two groups. Prospective group from 36 patients have been treated with oral or parenteral corticosteroids 7 - 14 days, other medications and fixed combination inhalers containing a F/S. Second, retrospective group from 34 patients have been treated with oral or parenteral corticosteroids 7 - 14 days (in time when we didn’t have fixed combination inhalers containing a F/S) and other medications. In both groups (prospective and retrospective) the most frequent etiological factors of AECOPD was bacterial infection, after that viral infection, other factors as well as congestive heart failure. Average recovery time for symptoms of AECOPD was statistically significant shorter in group patients treated with fixed combination inhalers containing F/S (prospective group) than in group treated without this fixed combination. There are also significant differences in average number of days need for recovery in subgroups of patients by etiological factors of AECOPD, except in cases of AECOPD onset because of congestive heart failure. Average free time from exacerbation at the patients treated with fixed combination inhalers was statistically significant longer than in group of patients who were not treated with this combination. In this study has demonstrated the presence of pathogenic bacteria in 53% our patients hospitalized due to AECOPD. There were 26% patients whose exacerbation is signed as viral origin. 11% cases had congestive heart failure. Average recovery time for non-viral AECOPD was 14,8 days and for exacerbations of viral origin 27,4 days. Average free time from exacerbation at the patients treated with fixed combination inhalers containing a F/S was statistically significant longer than in group of patients who were not treated with this combination. There were no statistically significant differences in average number of exacerbation during the year, between observed groups. PMID:18039195
NASA Technical Reports Server (NTRS)
Frew, A. M.; Eisenhut, D. F.; Farrenkopf, R. L.; Gates, R. F.; Iwens, R. P.; Kirby, D. K.; Mann, R. J.; Spencer, D. J.; Tsou, H. S.; Zaremba, J. G.
1972-01-01
The precision pointing control system (PPCS) is an integrated system for precision attitude determination and orientation of gimbaled experiment platforms. The PPCS concept configures the system to perform orientation of up to six independent gimbaled experiment platforms to design goal accuracy of 0.001 degrees, and to operate in conjunction with a three-axis stabilized earth-oriented spacecraft in orbits ranging from low altitude (200-2500 n.m., sun synchronous) to 24 hour geosynchronous, with a design goal life of 3 to 5 years. The system comprises two complementary functions: (1) attitude determination where the attitude of a defined set of body-fixed reference axes is determined relative to a known set of reference axes fixed in inertial space; and (2) pointing control where gimbal orientation is controlled, open-loop (without use of payload error/feedback) with respect to a defined set of body-fixed reference axes to produce pointing to a desired target.
Human's choices in situations of time-based diminishing returns.
Hackenberg, T D; Axtell, S A
1993-01-01
Three experiments examined adult humans' choices in situations with contrasting short-term and long-term consequences. Subjects were given repeated choices between two time-based schedules of points exchangeable for money: a fixed schedule and a progressive schedule that began at 0 s and increased by 5 s with each point delivered by that schedule. Under "reset" conditions, choosing the fixed schedule not only produced a point but it also reset the requirements of the progressive schedule to 0 s. In the first two experiments, reset conditions alternated with "no-reset" conditions, in which progressive-schedule requirements were independent of fixed-schedule choices. Experiment 1 entailed choices between a progressive-interval schedule and a fixed-interval schedule, the duration of which varied across conditions. Switching from the progressive- to the fixed-interval schedule was systematically related to fixed-interval size in 4 of 8 subjects, and in all subjects occurred consistently sooner in the progressive-schedule sequence under reset than under no-reset procedures. The latter result was replicated in a second experiment, in which choices between progressive- and fixed-interval schedules were compared with choices between progressive- and fixed-time schedules. In Experiment 3, switching patterns under reset conditions were unrelated to variations in intertrial interval. In none of the experiments did orderly choice patterns depend on verbal descriptions of the contingencies or on schedule-controlled response patterns in the presence of the chosen schedules. The overall pattern of results indicates control of choices by temporarily remote consequences, and is consistent with versions of optimality theory that address performance in situations of diminishing returns. PMID:8315364
Handa, Tarun; Jhajra, Shalu; Bhagat, Shweta; Bharatam, P V; Chakraborti, Asit K; Singh, Saranjit
2017-03-20
Combination therapy with the use of fixed-dose combinations (FDCs) is evincing increasing interest of prescribers, manufacturers and even regulators, evidently due to the primary benefit of improved patient compliance. However, owing to potential of drug-drug interaction, FDCs require closer scrutiny with respect to their physical and chemical stability. Accordingly, the purpose of the present study was to explore stability behavior of a popular antihypertensive combination of amlodipine besylate (AML) and losartan potassium (LST). Physical mixtures of the two drugs and multiple marketed formulations were stored under accelerated conditions of temperature and humidity (40°C/75% RH) in a stability chamber and samples were withdrawn after 1 and 3 months. The physical changes were observed visibly, while chemical changes were monitored by HPLC employing a method that could separate the two drugs and all other components present. The combination revealed strong physical instability and also chemical degradation of AML in the presence of LST. Interestingly, three isomeric interaction products of AML were formed in the combination, which otherwise were reported in the literature to be generated on exposure of AML free base above its melting point. The same unusual products were even formed when multiple marketed FDCs were stored under accelerated conditions outside their storage packs. However, these were absent when AML alone was stored in the same studied conditions. Therefore, reasons for physical and chemical incompatibility and the mechanism of degradation of AML in the presence of LST were duly explored at the molecular level. The outcomes of the study are expected to help in development of stable FDCs of the two drugs. Copyright © 2016 Elsevier B.V. All rights reserved.
Asgharzadeh, Hafez; Borazjani, Iman
2017-02-15
The explicit and semi-implicit schemes in flow simulations involving complex geometries and moving boundaries suffer from time-step size restriction and low convergence rates. Implicit schemes can be used to overcome these restrictions, but implementing them to solve the Navier-Stokes equations is not straightforward due to their non-linearity. Among the implicit schemes for nonlinear equations, Newton-based techniques are preferred over fixed-point techniques because of their high convergence rate but each Newton iteration is more expensive than a fixed-point iteration. Krylov subspace methods are one of the most advanced iterative methods that can be combined with Newton methods, i.e., Newton-Krylov Methods (NKMs) to solve non-linear systems of equations. The success of NKMs vastly depends on the scheme for forming the Jacobian, e.g., automatic differentiation is very expensive, and matrix-free methods without a preconditioner slow down as the mesh is refined. A novel, computationally inexpensive analytical Jacobian for NKM is developed to solve unsteady incompressible Navier-Stokes momentum equations on staggered overset-curvilinear grids with immersed boundaries. Moreover, the analytical Jacobian is used to form preconditioner for matrix-free method in order to improve its performance. The NKM with the analytical Jacobian was validated and verified against Taylor-Green vortex, inline oscillations of a cylinder in a fluid initially at rest, and pulsatile flow in a 90 degree bend. The capability of the method in handling complex geometries with multiple overset grids and immersed boundaries is shown by simulating an intracranial aneurysm. It was shown that the NKM with an analytical Jacobian is 1.17 to 14.77 times faster than the fixed-point Runge-Kutta method, and 1.74 to 152.3 times (excluding an intensively stretched grid) faster than automatic differentiation depending on the grid (size) and the flow problem. In addition, it was shown that using only the diagonal of the Jacobian further improves the performance by 42 - 74% compared to the full Jacobian. The NKM with an analytical Jacobian showed better performance than the fixed point Runge-Kutta because it converged with higher time steps and in approximately 30% less iterations even when the grid was stretched and the Reynold number was increased. In fact, stretching the grid decreased the performance of all methods, but the fixed-point Runge-Kutta performance decreased 4.57 and 2.26 times more than NKM with a diagonal Jacobian when the stretching factor was increased, respectively. The NKM with a diagonal analytical Jacobian and matrix-free method with an analytical preconditioner are the fastest methods and the superiority of one to another depends on the flow problem. Furthermore, the implemented methods are fully parallelized with parallel efficiency of 80-90% on the problems tested. The NKM with the analytical Jacobian can guide building preconditioners for other techniques to improve their performance in the future.
Asgharzadeh, Hafez; Borazjani, Iman
2016-01-01
The explicit and semi-implicit schemes in flow simulations involving complex geometries and moving boundaries suffer from time-step size restriction and low convergence rates. Implicit schemes can be used to overcome these restrictions, but implementing them to solve the Navier-Stokes equations is not straightforward due to their non-linearity. Among the implicit schemes for nonlinear equations, Newton-based techniques are preferred over fixed-point techniques because of their high convergence rate but each Newton iteration is more expensive than a fixed-point iteration. Krylov subspace methods are one of the most advanced iterative methods that can be combined with Newton methods, i.e., Newton-Krylov Methods (NKMs) to solve non-linear systems of equations. The success of NKMs vastly depends on the scheme for forming the Jacobian, e.g., automatic differentiation is very expensive, and matrix-free methods without a preconditioner slow down as the mesh is refined. A novel, computationally inexpensive analytical Jacobian for NKM is developed to solve unsteady incompressible Navier-Stokes momentum equations on staggered overset-curvilinear grids with immersed boundaries. Moreover, the analytical Jacobian is used to form preconditioner for matrix-free method in order to improve its performance. The NKM with the analytical Jacobian was validated and verified against Taylor-Green vortex, inline oscillations of a cylinder in a fluid initially at rest, and pulsatile flow in a 90 degree bend. The capability of the method in handling complex geometries with multiple overset grids and immersed boundaries is shown by simulating an intracranial aneurysm. It was shown that the NKM with an analytical Jacobian is 1.17 to 14.77 times faster than the fixed-point Runge-Kutta method, and 1.74 to 152.3 times (excluding an intensively stretched grid) faster than automatic differentiation depending on the grid (size) and the flow problem. In addition, it was shown that using only the diagonal of the Jacobian further improves the performance by 42 – 74% compared to the full Jacobian. The NKM with an analytical Jacobian showed better performance than the fixed point Runge-Kutta because it converged with higher time steps and in approximately 30% less iterations even when the grid was stretched and the Reynold number was increased. In fact, stretching the grid decreased the performance of all methods, but the fixed-point Runge-Kutta performance decreased 4.57 and 2.26 times more than NKM with a diagonal Jacobian when the stretching factor was increased, respectively. The NKM with a diagonal analytical Jacobian and matrix-free method with an analytical preconditioner are the fastest methods and the superiority of one to another depends on the flow problem. Furthermore, the implemented methods are fully parallelized with parallel efficiency of 80–90% on the problems tested. The NKM with the analytical Jacobian can guide building preconditioners for other techniques to improve their performance in the future. PMID:28042172
NASA Astrophysics Data System (ADS)
Asgharzadeh, Hafez; Borazjani, Iman
2017-02-01
The explicit and semi-implicit schemes in flow simulations involving complex geometries and moving boundaries suffer from time-step size restriction and low convergence rates. Implicit schemes can be used to overcome these restrictions, but implementing them to solve the Navier-Stokes equations is not straightforward due to their non-linearity. Among the implicit schemes for non-linear equations, Newton-based techniques are preferred over fixed-point techniques because of their high convergence rate but each Newton iteration is more expensive than a fixed-point iteration. Krylov subspace methods are one of the most advanced iterative methods that can be combined with Newton methods, i.e., Newton-Krylov Methods (NKMs) to solve non-linear systems of equations. The success of NKMs vastly depends on the scheme for forming the Jacobian, e.g., automatic differentiation is very expensive, and matrix-free methods without a preconditioner slow down as the mesh is refined. A novel, computationally inexpensive analytical Jacobian for NKM is developed to solve unsteady incompressible Navier-Stokes momentum equations on staggered overset-curvilinear grids with immersed boundaries. Moreover, the analytical Jacobian is used to form a preconditioner for matrix-free method in order to improve its performance. The NKM with the analytical Jacobian was validated and verified against Taylor-Green vortex, inline oscillations of a cylinder in a fluid initially at rest, and pulsatile flow in a 90 degree bend. The capability of the method in handling complex geometries with multiple overset grids and immersed boundaries is shown by simulating an intracranial aneurysm. It was shown that the NKM with an analytical Jacobian is 1.17 to 14.77 times faster than the fixed-point Runge-Kutta method, and 1.74 to 152.3 times (excluding an intensively stretched grid) faster than automatic differentiation depending on the grid (size) and the flow problem. In addition, it was shown that using only the diagonal of the Jacobian further improves the performance by 42-74% compared to the full Jacobian. The NKM with an analytical Jacobian showed better performance than the fixed point Runge-Kutta because it converged with higher time steps and in approximately 30% less iterations even when the grid was stretched and the Reynold number was increased. In fact, stretching the grid decreased the performance of all methods, but the fixed-point Runge-Kutta performance decreased 4.57 and 2.26 times more than NKM with a diagonal and full Jacobian, respectivley, when the stretching factor was increased. The NKM with a diagonal analytical Jacobian and matrix-free method with an analytical preconditioner are the fastest methods and the superiority of one to another depends on the flow problem. Furthermore, the implemented methods are fully parallelized with parallel efficiency of 80-90% on the problems tested. The NKM with the analytical Jacobian can guide building preconditioners for other techniques to improve their performance in the future.
Fixed-dose combination therapy for the prevention of cardiovascular disease
de Cates, Angharad N; Farr, Matthew RB; Rees, Karen; Casas, Juan P; Huffman, Mark
2014-01-01
This is the protocol for a review and there is no abstract. The objectives are as follows: To determine the effectiveness of fixed-dose combination therapy on optimising CVD risk factors and reducing CVD fatal and non-fatal events for both primary and secondary prevention of CVD. Details of CVD events and risk factors included are listed in the methods. We will also determine any adverse events associated with taking fixed-dose combination therapy. This will include studies conducted in both developed and developing regions of the world. PMID:25267903
Kobalava, Z D; Villevalde, S V; Kulakov, V V
2017-11-01
To study effects of a fixed azilsartan medoxomil/chlorthalidone combination (Edarbi Clo) on clinical, ambulatory and central blood pressure (BP) in patients with uncontrolled arterial hypertension (AH)). Patients (n=25) with uncontrolled AH were given fixed azilsartan medoxomil/chlorthalidone combination (40 / 12.5 mg / day) for 4 weeks. After 4 weeks, in patients who did not achieve target BP levels the dose was increased up to 40 / 25 mg / day. Duration of the study was 12 weeks. After 12 weeks of treatment 88 % of patients achieved target clinical BP (.
When water does not boil at the boiling point.
Chang, Hasok
2007-03-01
Every schoolchild learns that, under standard pressure, pure water always boils at 100 degrees C. Except that it does not. By the late 18th century, pioneering scientists had already discovered great variations in the boiling temperature of water under fixed pressure. So, why have most of us been taught that the boiling point of water is constant? And, if it is not constant, how can it be used as a 'fixed point' for the calibration of thermometers? History of science has the answers.
A test of fixed and moving reference point control in posture.
Lee, I-Chieh; Pacheco, Matheus M; Newell, Karl M
2017-01-01
This study investigated two contrasting assumptions of the regulation of posture: namely, fixed and moving reference point control. These assumptions were tested in terms of time-dependent structure and data distribution properties when stability is manipulated. Fifteen male participants performed a tightrope simulated balance task that is, maintaining a tandem stance while holding a pole. Pole length (and mass) and the standing support surface (fixed surface/balance board) were manipulated so as to mechanically change the balance stability. The mean and standard deviation (SD) of COP length were reduced with pole length increment but only in the balance board surface condition. Also, the SampEn was lower with greater pole length for the balance board but not the fixed surface. More than one peak was present in the distribution of COP in the majority of trials. Collectively, the findings provide evidence for a moving reference point in the maintenance of postural stability for quiet standing. Copyright © 2016 Elsevier B.V. All rights reserved.
Mishima, K; Yamashita, K
2009-07-07
We develop monotonically convergent free-time and fixed end-point optimal control theory (OCT) in the density-matrix representation to deal with quantum systems showing dissipation. Our theory is more general and flexible for tailoring optimal laser pulses in order to control quantum dynamics with dissipation than the conventional fixed-time and fixed end-point OCT in that the optimal temporal duration of laser pulses can also be optimized exactly. To show the usefulness of our theory, it is applied to the generation and maintenance of the vibrational entanglement of carbon monoxide adsorbed on the copper (100) surface, CO/Cu(100). We demonstrate the numerical results and clarify how to combat vibrational decoherence as much as possible by the tailored shapes of the optimal laser pulses. It is expected that our theory will be general enough to be applied to a variety of dissipative quantum dynamics systems because the decoherence is one of the quantum phenomena sensitive to the temporal duration of the quantum dynamics.
Designing Image Operators for MRI-PET Image Fusion of the Brain
NASA Astrophysics Data System (ADS)
Márquez, Jorge; Gastélum, Alfonso; Padilla, Miguel A.
2006-09-01
Our goal is to obtain images combining in a useful and precise way the information from 3D volumes of medical imaging sets. We address two modalities combining anatomy (Magnetic Resonance Imaging or MRI) and functional information (Positron Emission Tomography or PET). Commercial imaging software offers image fusion tools based on fixed blending or color-channel combination of two modalities, and color Look-Up Tables (LUTs), without considering the anatomical and functional character of the image features. We used a sensible approach for image fusion taking advantage mainly from the HSL (Hue, Saturation and Luminosity) color space, in order to enhance the fusion results. We further tested operators for gradient and contour extraction to enhance anatomical details, plus other spatial-domain filters for functional features corresponding to wide point-spread-function responses in PET images. A set of image-fusion operators was formulated and tested on PET and MRI acquisitions.
Abe, Masanori; Okada, Kazuyoshi; Matsumoto, Koichi
2009-10-01
The goal of antihypertensive treatment is to reduce cardiovascular and cerebrovascular events associated with high blood pressure. A combination therapy with different antihypertensive agents is more successful than monotherapy in most hypertensive patients, with the added advantage of a better safety profile. Therefore, treatment of hypertensive patients with fixed-dose combination therapy consisting of the angiotensin II receptor blocker losartan along with hydrochlorothiazide (HCTZ) has several potential benefits over monotherapy with each individual component. It provides more effective blood pressure control, a reduction in the likelihood of adverse effects and facilitation of patient compliance due to a simple once-daily regimen. One of the advantages of the combination of losartan with HCTZ is the potential reduction in HCTZ-induced metabolic disorders; in particular, this combination can have attractive benefits for patients of hyperuricemia. Losartan plus HCTZ fixed-dose combination therapy is frequently recommended for the treatment of hypertension and lowers blood pressure in mild-to-moderate and even severe hypertensive patients to a level comparable with other classes of antihypertensive agents in combination with HCTZ. Fixed-dose combination therapy with losartan plus HCTZ is a logical choice as antihypertensive therapy for patients in whom combination therapy is necessary to achieve additional blood pressure reduction.
ERIC Educational Resources Information Center
Kuntz, Aaron M.; Petrovic, John E.
2018-01-01
In this article we consider the material dimensions of schooling as constitutive of the possibilities inherent in "fixing" education. We begin by mapping out the problem of "fixing education," pointing to the necrophilic tendencies of contemporary education--a desire to kill what otherwise might be life-giving. In this sense,…
NASA Astrophysics Data System (ADS)
Lampitt, Richard; Cristini, Luisa
2014-05-01
The Fixed point Open Ocean Observatory network (FixO3) seeks to integrate the 23 European open ocean fixed point observatories and to improve access to these key installations for the broader community. These will provide multidisciplinary observations in all parts of the oceans from the air-sea interface to the deep seafloor. Coordinated by the National Oceanography Centre, UK, FixO3 builds on the significant advances achieved through the previous Europe-funded FP7 programmes EuroSITES, ESONET and CARBOOCEAN. Started in September 2013 with a budget of 7 Million Euros over 4 years the project has 29 partners drawn from academia, research institutions and SME's. In addition 12 international experts from a wide range of disciplines comprise an Advisory Board. On behalf of the FixO3 Consortium, we present the programme that will be achieved through the activities of 12 Work Packages: 1. Coordination activities to integrate and harmonise the current procedures and processes. Strong links will be fostered with the wider community across academia, industry, policy and the general public through outreach, knowledge exchange and training. 2. Support actions to offer a) free access to observatory infrastructures to those who do not have such access, and b) free and open data services and products. 3. Joint research activities to innovate and enhance the current capability for multidisciplinary in situ ocean observation. Support actions include Transnational Access (TNA) to FixO3 infrastructure, meaning that European organizations can apply to free-of-charge access to the observatories for research and testing in two international calls during the project lifetime. The first call for TNA opens in summer 2014. More information can be found on FixO3 website (www.fixo3.eu/). Open ocean observation is currently a high priority for European marine and maritime activities. FixO3 will provide important data on environmental products and services to address the Marine Strategy Framework Directive and in support of the European Integrated Maritime Policy. The FixO3 network will provide free and open access to in situ fixed point data of the highest quality. It will provide a strong integrated framework of open ocean facilities in the Atlantic from the Arctic to the Antarctic and throughout the Mediterranean, enabling an integrated, regional and multidisciplinary approach to understand natural and anthropogenic change in the ocean.
Nikbakhtsarvestani, Farzaneh; Vaezpour, S Mansour; Asadi, Mehdi
2017-01-01
In this paper, some new generalization of Darbo's fixed point theorem is proved by using a [Formula: see text]-contraction in terms of a measure of noncompactness. Our result extends to obtaining a common fixed point for a pair of compatible mappings. The paper contains an application for nonlinear integral equations as well.
Fixed Point Theorems for Hybrid Mappings
Kamran, Tayyab; Karapinar, Erdal
2015-01-01
We obtain some fixed point theorems for two pairs of hybrid mappings using hybrid tangential property and quadratic type contractive condition. Our results generalize some results by Babu and Alemayehu and those contained therein. In the sequel, we introduce a new notion to generalize occasionally weak compatibility. Moreover, two concrete examples are established to illuminate the generality of our results. PMID:25629089
Fixed Point Problems for Linear Transformations on Pythagorean Triples
ERIC Educational Resources Information Center
Zhan, M.-Q.; Tong, J.-C.; Braza, P.
2006-01-01
In this article, an attempt is made to find all linear transformations that map a standard Pythagorean triple (a Pythagorean triple [x y z][superscript T] with y being even) into a standard Pythagorean triple, which have [3 4 5][superscript T] as their fixed point. All such transformations form a monoid S* under matrix product. It is found that S*…
Fixed-Radius Point Counts in Forests: Factors Influencing Effectiveness and Efficiency
Daniel R. Petit; Lisa J. Petit; Victoria A. Saab; Thomas E. Martin
1995-01-01
The effectiveness of fixed-radius point counts in quantifying abundance and richness of bird species in oak-hickory, pine-hardwoods, mixed-mesophytic, beech-maple, and riparian cottonwood forests was evaluated in Arkansas, Ohio, Kentucky, and Idaho. Effects of count duration and numbers of stations and visits per stand were evaluated in May to July 1991 by conducting...
A MAP fixed-point, packing-unpacking routine for the IBM 7094 computer
Robert S. Helfman
1966-01-01
Two MAP (Macro Assembly Program) computer routines for packing and unpacking fixed point data are described. Use of these routines with Fortran IV Programs provides speedy access to quantities of data which far exceed the normal storage capacity of IBM 7000-series computers. Many problems that could not be attempted because of the slow access-speed of tape...
Quantum group spin nets: Refinement limit and relation to spin foams
NASA Astrophysics Data System (ADS)
Dittrich, Bianca; Martin-Benito, Mercedes; Steinhaus, Sebastian
2014-07-01
So far spin foam models are hardly understood beyond a few of their basic building blocks. To make progress on this question, we define analogue spin foam models, so-called "spin nets," for quantum groups SU(2)k and examine their effective continuum dynamics via tensor network renormalization. In the refinement limit of this coarse-graining procedure, we find a vast nontrivial fixed-point structure beyond the degenerate and the BF phase. In comparison to previous work, we use fixed-point intertwiners, inspired by Reisenberger's construction principle [M. P. Reisenberger, J. Math. Phys. (N.Y.) 40, 2046 (1999)] and the recent work [B. Dittrich and W. Kaminski, arXiv:1311.1798], as the initial parametrization. In this new parametrization fine-tuning is not required in order to flow to these new fixed points. Encouragingly, each fixed point has an associated extended phase, which allows for the study of phase transitions in the future. Finally we also present an interpretation of spin nets in terms of melonic spin foams. The coarse-graining flow of spin nets can thus be interpreted as describing the effective coupling between two spin foam vertices or space time atoms.
How nonperturbative is the infrared regime of Landau gauge Yang-Mills correlators?
NASA Astrophysics Data System (ADS)
Reinosa, U.; Serreau, J.; Tissier, M.; Wschebor, N.
2017-07-01
We study the Landau gauge correlators of Yang-Mills fields for infrared Euclidean momenta in the context of a massive extension of the Faddeev-Popov Lagrangian which, we argue, underlies a variety of continuum approaches. Standard (perturbative) renormalization group techniques with a specific, infrared-safe renormalization scheme produce so-called decoupling and scaling solutions for the ghost and gluon propagators, which correspond to nontrivial infrared fixed points. The decoupling fixed point is infrared stable and weakly coupled, while the scaling fixed point is unstable and generically strongly coupled except for low dimensions d →2 . Under the assumption that such a scaling fixed point exists beyond one-loop order, we find that the corresponding ghost and gluon scaling exponents are, respectively, 2 αF=2 -d and 2 αG=d at all orders of perturbation theory in the present renormalization scheme. We discuss the relation between the ghost wave function renormalization, the gluon screening mass, the scale of spectral positivity violation, and the gluon mass parameter. We also show that this scaling solution does not realize the standard Becchi-Rouet-Stora-Tyutin symmetry of the Faddeev-Popov Lagrangian. Finally, we discuss our findings in relation to the results of nonperturbative continuum methods.
Stochastic oscillations in models of epidemics on a network of cities
NASA Astrophysics Data System (ADS)
Rozhnova, G.; Nunes, A.; McKane, A. J.
2011-11-01
We carry out an analytic investigation of stochastic oscillations in a susceptible-infected-recovered model of disease spread on a network of n cities. In the model a fraction fjk of individuals from city k commute to city j, where they may infect, or be infected by, others. Starting from a continuous-time Markov description of the model the deterministic equations, which are valid in the limit when the population of each city is infinite, are recovered. The stochastic fluctuations about the fixed point of these equations are derived by use of the van Kampen system-size expansion. The fixed point structure of the deterministic equations is remarkably simple: A unique nontrivial fixed point always exists and has the feature that the fraction of susceptible, infected, and recovered individuals is the same for each city irrespective of its size. We find that the stochastic fluctuations have an analogously simple dynamics: All oscillations have a single frequency, equal to that found in the one-city case. We interpret this phenomenon in terms of the properties of the spectrum of the matrix of the linear approximation of the deterministic equations at the fixed point.
Natural Whisker-Guided Behavior by Head-Fixed Mice in Tactile Virtual Reality
Sofroniew, Nicholas J.; Cohen, Jeremy D.; Lee, Albert K.
2014-01-01
During many natural behaviors the relevant sensory stimuli and motor outputs are difficult to quantify. Furthermore, the high dimensionality of the space of possible stimuli and movements compounds the problem of experimental control. Head fixation facilitates stimulus control and movement tracking, and can be combined with techniques for recording and manipulating neural activity. However, head-fixed mouse behaviors are typically trained through extensive instrumental conditioning. Here we present a whisker-based, tactile virtual reality system for head-fixed mice running on a spherical treadmill. Head-fixed mice displayed natural movements, including running and rhythmic whisking at 16 Hz. Whisking was centered on a set point that changed in concert with running so that more protracted whisking was correlated with faster running. During turning, whiskers moved in an asymmetric manner, with more retracted whisker positions in the turn direction and protracted whisker movements on the other side. Under some conditions, whisker movements were phase-coupled to strides. We simulated a virtual reality tactile corridor, consisting of two moveable walls controlled in a closed-loop by running speed and direction. Mice used their whiskers to track the walls of the winding corridor without training. Whisker curvature changes, which cause forces in the sensory follicles at the base of the whiskers, were tightly coupled to distance from the walls. Our behavioral system allows for precise control of sensorimotor variables during natural tactile navigation. PMID:25031397
Cosmic infinity: a dynamical system approach
NASA Astrophysics Data System (ADS)
Bouhmadi-López, Mariam; Marto, João; Morais, João; Silva, César M.
2017-03-01
Dynamical system techniques are extremely useful to study cosmology. It turns out that in most of the cases, we deal with finite isolated fixed points corresponding to a given cosmological epoch. However, it is equally important to analyse the asymptotic behaviour of the universe. On this paper, we show how this can be carried out for 3-form models. In fact, we show that there are fixed points at infinity mainly by introducing appropriate compactifications and defining a new time variable that washes away any potential divergence of the system. The richness of 3-form models allows us as well to identify normally hyperbolic non-isolated fixed points. We apply this analysis to three physically interesting situations: (i) a pre-inflationary era; (ii) an inflationary era; (iii) the late-time dark matter/dark energy epoch.
Quantum corrections to non-Abelian SUSY theories on orbifolds
NASA Astrophysics Data System (ADS)
Groot Nibbelink, Stefan; Hillenbach, Mark
2006-07-01
We consider supersymmetric non-Abelian gauge theories coupled to hyper multiplets on five and six dimensional orbifolds, S/Z and T/Z, respectively. We compute the bulk and local fixed point renormalizations of the gauge couplings. To this end we extend supergraph techniques to these orbifolds by defining orbifold compatible delta functions. We develop their properties in detail. To cancel the bulk one-loop divergences the bulk gauge kinetic terms and dimension six higher derivative operators are required. The gauge couplings renormalize at the Z fixed points due to vector multiplet self interactions; the hyper multiplet renormalizes only non- Z fixed points. In 6D the Wess-Zumino-Witten term and a higher derivative analogue have to renormalize in the bulk as well to preserve 6D gauge invariance.
Non-Kondo many-body physics in a Majorana-based Kondo type system
NASA Astrophysics Data System (ADS)
van Beek, Ian J.; Braunecker, Bernd
2016-09-01
We carry out a theoretical analysis of a prototypical Majorana system, which demonstrates the existence of a Majorana-mediated many-body state and an associated intermediate low-energy fixed point. Starting from two Majorana bound states, hosted by a Coulomb-blockaded topological superconductor and each coupled to a separate lead, we derive an effective low-energy Hamiltonian, which displays a Kondo-like character. However, in contrast to the Kondo model which tends to a strong- or weak-coupling limit under renormalization, we show that this effective Hamiltonian scales to an intermediate fixed point, whose existence is contingent upon teleportation via the Majorana modes. We conclude by determining experimental signatures of this fixed point, as well as the exotic many-body state associated with it.
Nonminimal hints for asymptotic safety
NASA Astrophysics Data System (ADS)
Eichhorn, Astrid; Lippoldt, Stefan; Skrinjar, Vedran
2018-01-01
In the asymptotic-safety scenario for gravity, nonzero interactions are present in the ultraviolet. This property should also percolate into the matter sector. Symmetry-based arguments suggest that nonminimal derivative interactions of scalars with curvature tensors should therefore be present in the ultraviolet regime. We perform a nonminimal test of the viability of the asymptotic-safety scenario by working in a truncation of the renormalization group flow, where we discover the existence of an interacting fixed point for a corresponding nonminimal coupling. The back-coupling of such nonminimal interactions could in turn destroy the asymptotically safe fixed point in the gravity sector. As a key finding, we observe nontrivial indications of stability of the fixed-point properties under the impact of nonminimal derivative interactions, further strengthening the case for asymptotic safety in gravity-matter systems.
NASA Astrophysics Data System (ADS)
Bojkovski, J.; Veliki, T.; Zvizdić, D.; Drnovšek, J.
2011-08-01
The objective of project EURAMET 1127 (Bilateral comparison of triple point of mercury and melting point of gallium) in the field of thermometry is to compare realization of a triple point of mercury (-38.8344 °C) and melting point of gallium (29.7646 °C) between the Slovenian national laboratory MIRS/UL-FE/LMK and the Croatian national laboratory HMI/FSB-LPM using a long-stem 25 Ω standard platinum resistance thermometer (SPRT). MIRS/UL/FE-LMK participated in a number of intercomparisons on the level of EURAMET. On the other hand, the HMI/LPM-FSB laboratory recently acquired new fixed-point cells which had to be evaluated in the process of intercomparisons. A quartz-sheathed SPRT has been selected and calibrated at HMI/LPM-FSB at the triple point of mercury, the melting point of gallium, and the water triple point. A second set of measurements was made at MIRS/UL/FE-LMK. After its return, the SPRT was again recalibrated at HMI/LPM-FSB. In the comparison, the W value of the SPRT has been used. Results of the bilateral intercomparison confirmed that the new gallium cell of the HMI/LPM-FSB has a value that is within uncertainty limits of both laboratories that participated in the exercise, while the mercury cell experienced problems. After further research, a small leakage in the mercury fixed-point cell has been found.
NASA Astrophysics Data System (ADS)
Battuello, M.; Girard, F.; Florio, M.
2009-02-01
Four independent radiation temperature scales approximating the ITS-90 at 900 nm, 950 nm and 1.6 µm have been realized from the indium point (429.7485 K) to the copper point (1357.77 K) which were used to derive by extrapolation the transition temperature T90(Co-C) of the cobalt-carbon eutectic fixed point. An INRIM cell was investigated and an average value T90(Co-C) = 1597.20 K was found with the four values lying within 0.25 K. Alternatively, thermodynamic approximated scales were realized by assigning to the fixed points the best presently available thermodynamic values and deriving T(Co-C). An average value of 1597.27 K was found (four values lying within 0.25 K). The standard uncertainties associated with T90(Co-C) and T(Co-C) were 0.16 K and 0.17 K, respectively. INRIM determinations are compatible with recent thermodynamic determinations on three different cells (values lying between 1597.11 K and 1597.25 K) and with the result of a comparison on the same cell by an absolute radiation thermometer and an irradiance measurement with filter radiometers which give values of 1597.11 K and 1597.43 K, respectively (Anhalt et al 2006 Metrologia 43 S78-83). The INRIM approach allows the determination of both ITS-90 and thermodynamic temperature of a fixed point in a simple way and can provide valuable support to absolute radiometric methods in defining the transition temperature of new high-temperature fixed points.
Safety of Adding Salmeterol to Fluticasone Propionate in Children with Asthma.
Stempel, David A; Szefler, Stanley J; Pedersen, Søren; Zeiger, Robert S; Yeakey, Anne M; Lee, Laurie A; Liu, Andrew H; Mitchell, Herman; Kral, Kenneth M; Raphiou, Ibrahim H; Prillaman, Barbara A; Buaron, Kathleen S; Yun Kirby, Suyong; Pascoe, Steven J
2016-09-01
Long-acting beta-agonists (LABAs) have been shown to increase the risk of asthma-related death among adults and the risk of asthma-related hospitalization among children. It is unknown whether the concomitant use of inhaled glucocorticoids with LABAs mitigates those risks. This trial prospectively evaluated the safety of the LABA salmeterol, added to fluticasone propionate, in a fixed-dose combination in children. We randomly assigned, in a 1:1 ratio, children 4 to 11 years of age who required daily asthma medications and had a history of asthma exacerbations in the previous year to receive fluticasone propionate plus salmeterol or fluticasone alone for 26 weeks. The primary safety end point was the first serious asthma-related event (death, endotracheal intubation, or hospitalization), as assessed in a time-to-event analysis. The statistical design specified that noninferiority would be shown if the upper boundary of the 95% confidence interval of the hazard ratio for the primary safety end point was less than 2.675. The main efficacy end point was the first severe asthma exacerbation that led to treatment with systemic glucocorticoids, as assessed in a time-to-event analysis. Among the 6208 patients, 27 patients in the fluticasone-salmeterol group and 21 in the fluticasone-alone group had a serious asthma-related event (all were hospitalizations); the hazard ratio with fluticasone-salmeterol versus fluticasone alone was 1.28 (95% confidence interval [CI], 0.73 to 2.27), which showed the noninferiority of fluticasone-salmeterol (P=0.006). A total of 265 patients (8.5%) in the fluticasone-salmeterol group and 309 (10.0%) in the fluticasone-alone group had a severe asthma exacerbation (hazard ratio, 0.86; 95% CI, 0.73 to 1.01). In this trial involving children with asthma, salmeterol in a fixed-dose combination with fluticasone was associated with the risk of a serious asthma-related event that was similar to the risk with fluticasone alone. (Funded by GlaxoSmithKline; VESTRI ClinicalTrials.gov number, NCT01462344 .).
A Comparison of Escalating versus Fixed Reinforcement Schedules on Undergraduate Quiz Taking
ERIC Educational Resources Information Center
Mahoney, Amanda
2017-01-01
Drug abstinence studies indicate that escalating reinforcement schedules maintain abstinence for longer periods than fixed reinforcement schedules. The current study evaluated whether escalating reinforcement schedules would maintain more quiz taking than fixed reinforcement schedules. During baseline and for the control group, bonus points were…
La, Moonwoo; Park, Sang Min; Kim, Dong Sung
2015-01-01
In this study, a multiple sample dispenser for precisely metered fixed volumes was successfully designed, fabricated, and fully characterized on a plastic centrifugal lab-on-a-disk (LOD) for parallel biochemical single-end-point assays. The dispenser, namely, a centrifugal multiplexing fixed-volume dispenser (C-MUFID) was designed with microfluidic structures based on the theoretical modeling about a centrifugal circumferential filling flow. The designed LODs were fabricated with a polystyrene substrate through micromachining and they were thermally bonded with a flat substrate. Furthermore, six parallel metering and dispensing assays were conducted at the same fixed-volume (1.27 μl) with a relative variation of ±0.02 μl. Moreover, the samples were metered and dispensed at different sub-volumes. To visualize the metering and dispensing performances, the C-MUFID was integrated with a serpentine micromixer during parallel centrifugal mixing tests. Parallel biochemical single-end-point assays were successfully conducted on the developed LOD using a standard serum with albumin, glucose, and total protein reagents. The developed LOD could be widely applied to various biochemical single-end-point assays which require different volume ratios of the sample and reagent by controlling the design of the C-MUFID. The proposed LOD is feasible for point-of-care diagnostics because of its mass-producible structures, reliable metering/dispensing performance, and parallel biochemical single-end-point assays, which can identify numerous biochemical. PMID:25610516
Shape Factor Modeling and Simulation
2016-06-01
endloop, endfacet, endsolid; 14 double nx, ny, nz , v1x, v1y, v1z, v2x, v2y, v2z, v3x, v3y, v3z; 15 double ax, ay, az, bx, by, bz; 16 17 std::cin...solid >> name; 18 19 int n_facets = 0; 20 double total_area = 0., volume = 0., mean_area; 21 while ( std::cin >> facet >> normal >> nx >> ny >> nz ...nx(aybz − azby) + ny(azbx − axbz) + nz (axby − aybx)]. (13) 3.4.2 Volume Contribution from Each Facet Each facet, combined with another fixed point d
Munteanu, Ioana; Husar, Iulia; Didilescu, C; Stoicescu, I P
2004-01-01
Here are presented the results of a prospective, randomized study regarding the efficiency of regimens with fixed drug combination Rifampicin-Isoniazide manufactured by Antibiotics S.A. of Iasi in comparison with single drugs routinely used in treatment of patients with pulmonary tuberculosis. Newly diagnosed (confirmed by smear and culture) pulmonary tuberculosis patients were selected, and those who accepted to be included in the study, were admitted to the National Institute of Pneumology "Marius Nasta" between August 2001 and September 2002. At the time of admission, they were randomized into two groups: 20 patients received fixed drug combination RMP300 HIN150, and 18 patients received RMP and HIN in single drug tablets (2 patients were excluded). The follow-up of the patients was for one year from the date of enclosure. The smear conversion rate was 83,3% for the patients using single drug tablets, and 70% for those using fixed drug combination, motivated with some more severe TB patterns. The success rate was 100% for all TB patients. Although the present study was done for few patients, we can say that it demonstrated the same efficiency of fixed drug combination produced in Romania, with the single drug tablets, and it suggests a better compliance to treatment with a lower price.
Structure of the entanglement entropy of (3+1)-dimensional gapped phases of matter
NASA Astrophysics Data System (ADS)
Zheng, Yunqin; He, Huan; Bradlyn, Barry; Cano, Jennifer; Neupert, Titus; Bernevig, B. Andrei
2018-05-01
We study the entanglement entropy of gapped phases of matter in three spatial dimensions. We focus in particular on size-independent contributions to the entropy across entanglement surfaces of arbitrary topologies. We show that for low energy fixed-point theories, the constant part of the entanglement entropy across any surface can be reduced to a linear combination of the entropies across a sphere and a torus. We first derive our results using strong sub-additivity inequalities along with assumptions about the entanglement entropy of fixed-point models, and identify the topological contribution by considering the renormalization group flow; in this way we give an explicit definition of topological entanglement entropy Stopo in (3+1)D, which sharpens previous results. We illustrate our results using several concrete examples and independent calculations, and show adding "twist" terms to the Lagrangian can change Stopo in (3+1)D. For the generalized Walker-Wang models, we find that the ground state degeneracy on a 3-torus is given by exp(-3 Stopo[T2] ) in terms of the topological entanglement entropy across a 2-torus. We conjecture that a similar relationship holds for Abelian theories in (d +1 ) dimensional spacetime, with the ground state degeneracy on the d -torus given by exp(-d Stopo[Td -1] ) .
ERIC Educational Resources Information Center
Bellver-Cebreros, Consuelo; Rodriguez-Danta, Marcelo
2009-01-01
An apparently unnoticed analogy between the torque-free motion of a rotating rigid body about a fixed point and the propagation of light in anisotropic media is stated. First, a new plane construction for visualizing this torque-free motion is proposed. This method uses an intrinsic representation alternative to angular momentum and independent of…
PPF Dependent Fixed Point Results for Triangular α c-Admissible Mappings
Ćirić, Ljubomir; Alsulami, Saud M.; Salimi, Peyman
2014-01-01
We introduce the concept of triangular α c-admissible mappings (pair of mappings) with respect to η c nonself-mappings and establish the existence of PPF dependent fixed (coincidence) point theorems for contraction mappings involving triangular α c-admissible mappings (pair of mappings) with respect to η c nonself-mappings in Razumikhin class. Several interesting consequences of our theorems are also given. PMID:24672352
NASA Astrophysics Data System (ADS)
Duran, Volkan; Gençten, Azmi
2016-03-01
In this research the aim is to analyze quantum qutrit entanglements in a new perspective in terms of the reflection of n-dimensional sphere which can be depicted as the set of points equidistant from a fixed central point in three dimensional Euclidian Space which has also real and imaginary dimensions, that can also be depicted similarly as a two unit spheres having same centre in a dome-shaped projection. In order to analyze quantum qutrit entanglements: i- a new type of n dimensional hyper-sphere which is the extend version of Bloch Sphere to hyper-space, is defined ii- new operators and products such as rotation operator, combining and gluing products in this space are defined, iii-the entangled states are analyzed in terms of those products in order to reach a general formula to depict qutrit entanglements and some new patterns between spheres for the analysis of entanglement for different routes in a more simple way in a four dimensional time independent hypersphere.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duran, Volkan, E-mail: volkan.duran8@gmail.com; Gençten, Azmi, E-mail: gencten@omu.edu.tr
In this research the aim is to analyze quantum qutrit entanglements in a new perspective in terms of the reflection of n-dimensional sphere which can be depicted as the set of points equidistant from a fixed central point in three dimensional Euclidian Space which has also real and imaginary dimensions, that can also be depicted similarly as a two unit spheres having same centre in a dome-shaped projection. In order to analyze quantum qutrit entanglements: i- a new type of n dimensional hyper-sphere which is the extend version of Bloch Sphere to hyper-space, is defined ii- new operators and productsmore » such as rotation operator, combining and gluing products in this space are defined, iii-the entangled states are analyzed in terms of those products in order to reach a general formula to depict qutrit entanglements and some new patterns between spheres for the analysis of entanglement for different routes in a more simple way in a four dimensional time independent hypersphere.« less
Precise Point Positioning with Partial Ambiguity Fixing.
Li, Pan; Zhang, Xiaohong
2015-06-10
Reliable and rapid ambiguity resolution (AR) is the key to fast precise point positioning (PPP). We propose a modified partial ambiguity resolution (PAR) method, in which an elevation and standard deviation criterion are first used to remove the low-precision ambiguity estimates for AR. Subsequently the success rate and ratio-test are simultaneously used in an iterative process to increase the possibility of finding a subset of decorrelated ambiguities which can be fixed with high confidence. One can apply the proposed PAR method to try to achieve an ambiguity-fixed solution when full ambiguity resolution (FAR) fails. We validate this method using data from 450 stations during DOY 021 to 027, 2012. Results demonstrate the proposed PAR method can significantly shorten the time to first fix (TTFF) and increase the fixing rate. Compared with FAR, the average TTFF for PAR is reduced by 14.9% for static PPP and 15.1% for kinematic PPP. Besides, using the PAR method, the average fixing rate can be increased from 83.5% to 98.2% for static PPP, from 80.1% to 95.2% for kinematic PPP respectively. Kinematic PPP accuracy with PAR can also be significantly improved, compared to that with FAR, due to a higher fixing rate.
Precise Point Positioning with Partial Ambiguity Fixing
Li, Pan; Zhang, Xiaohong
2015-01-01
Reliable and rapid ambiguity resolution (AR) is the key to fast precise point positioning (PPP). We propose a modified partial ambiguity resolution (PAR) method, in which an elevation and standard deviation criterion are first used to remove the low-precision ambiguity estimates for AR. Subsequently the success rate and ratio-test are simultaneously used in an iterative process to increase the possibility of finding a subset of decorrelated ambiguities which can be fixed with high confidence. One can apply the proposed PAR method to try to achieve an ambiguity-fixed solution when full ambiguity resolution (FAR) fails. We validate this method using data from 450 stations during DOY 021 to 027, 2012. Results demonstrate the proposed PAR method can significantly shorten the time to first fix (TTFF) and increase the fixing rate. Compared with FAR, the average TTFF for PAR is reduced by 14.9% for static PPP and 15.1% for kinematic PPP. Besides, using the PAR method, the average fixing rate can be increased from 83.5% to 98.2% for static PPP, from 80.1% to 95.2% for kinematic PPP respectively. Kinematic PPP accuracy with PAR can also be significantly improved, compared to that with FAR, due to a higher fixing rate. PMID:26067196
NASA Astrophysics Data System (ADS)
Battuello, M.; Florio, M.; Girard, F.
2010-06-01
An indirect determination of the thermodynamic temperature of the fixed point of copper was made at INRIM by measuring four cells with a Si-based and an InGaAs-based precision radiation thermometer carrying approximated thermodynamic scales realized up to the Ag point. An average value TCu = 1357.840 K was found with a standard uncertainty of 0.047 K. A consequent (T - T90)Cu value of 70 mK can be derived which is 18 mK higher than, but consistent with, the presently available (T - T90)Cu as elaborated by the CCT-WG4.
A test of the AdS/CFT duality on the Coulomb branch
NASA Astrophysics Data System (ADS)
Costa, M. S.
2000-06-01
We consider the /N=4 /SU(N) Super Yang Mills theory on the Coulomb branch with gauge symmetry broken to S(U(N1)×U(N2)). By integrating the W particles, the effective action near the IR SU(Ni) conformal fixed points is seen to be a deformation of the Super Yang Mills theory by a non-renormalized, irrelevant, dimension 8 operator. The correction to the two-point function of the dilaton field dual operator near the IR is related to a three-point function of chiral primary operators at the conformal fixed points and agrees with the classical gravity prediction, including the numerical factor.
Floquet stability analysis of the longitudinal dynamics of two hovering model insects
Wu, Jiang Hao; Sun, Mao
2012-01-01
Because of the periodically varying aerodynamic and inertial forces of the flapping wings, a hovering or constant-speed flying insect is a cyclically forcing system, and, generally, the flight is not in a fixed-point equilibrium, but in a cyclic-motion equilibrium. Current stability theory of insect flight is based on the averaged model and treats the flight as a fixed-point equilibrium. In the present study, we treated the flight as a cyclic-motion equilibrium and used the Floquet theory to analyse the longitudinal stability of insect flight. Two hovering model insects were considered—a dronefly and a hawkmoth. The former had relatively high wingbeat frequency and small wing-mass to body-mass ratio, and hence very small amplitude of body oscillation; while the latter had relatively low wingbeat frequency and large wing-mass to body-mass ratio, and hence relatively large amplitude of body oscillation. For comparison, analysis using the averaged-model theory (fixed-point stability analysis) was also made. Results of both the cyclic-motion stability analysis and the fixed-point stability analysis were tested by numerical simulation using complete equations of motion coupled with the Navier–Stokes equations. The Floquet theory (cyclic-motion stability analysis) agreed well with the simulation for both the model dronefly and the model hawkmoth; but the averaged-model theory gave good results only for the dronefly. Thus, for an insect with relatively large body oscillation at wingbeat frequency, cyclic-motion stability analysis is required, and for their control analysis, the existing well-developed control theories for systems of fixed-point equilibrium are no longer applicable and new methods that take the cyclic variation of the flight dynamics into account are needed. PMID:22491980
NASA Astrophysics Data System (ADS)
da Silva, Rodrigo; Pearce, Jonathan V.; Machin, Graham
2017-06-01
The fixed points of the International Temperature Scale of 1990 (ITS-90) are the basis of the calibration of standard platinum resistance thermometers (SPRTs). Impurities in the fixed point material at the level of parts per million can give rise to an elevation or depression of the fixed point temperature of order of millikelvins, which often represents the most significant contribution to the uncertainty of SPRT calibrations. A number of methods for correcting for the effect of impurities have been advocated, but it is becoming increasingly evident that no single method can be used in isolation. In this investigation, a suite of five aluminium fixed point cells (defined ITS-90 freezing temperature 660.323 °C) have been constructed, each cell using metal sourced from a different supplier. The five cells have very different levels and types of impurities. For each cell, chemical assays based on the glow discharge mass spectroscopy (GDMS) technique have been obtained from three separate laboratories. In addition a series of high quality, long duration freezing curves have been obtained for each cell, using three different high quality SPRTs, all measured under nominally identical conditions. The set of GDMS analyses and freezing curves were then used to compare the different proposed impurity correction methods. It was found that the most consistent corrections were obtained with a hybrid correction method based on the sum of individual estimates (SIE) and overall maximum estimate (OME), namely the SIE/Modified-OME method. Also highly consistent was the correction technique based on fitting a Scheil solidification model to the measured freezing curves, provided certain well defined constraints are applied. Importantly, the most consistent methods are those which do not depend significantly on the chemical assay.
Song, Hyung Keun; Yoo, Je Hyun; Byun, Young Soo
2014-01-01
Purpose Among patients over 50 years of age, separate vertical wiring alone may be insufficient for fixation of fractures of the inferior pole of the patella. Therefore, mechanical and clinical studies were performed in patients over the age of 50 to test the strength of augmentation of separate vertical wiring with cerclage wire (i.e., combined technique). Materials and Methods Multiple osteotomies were performed to create four-part fractures in the inferior poles of eight pairs of cadaveric patellae. One patella from each pair was fixed with the separate wiring technique, while the other patella was fixed with a combined technique. The ultimate load to failure and stiffness of the fixation were subsequently measured. In a clinical study of 21 patients (average age of 64 years), comminuted fractures of the inferior pole of the patellae were treated using the combined technique. Operative parameters were recorded from which post-operative outcomes were evaluated. Results For cadaveric patellae, whose mean age was 69 years, the mean ultimate loads to failure for the separate vertical wiring technique and the combined technique were 216.4±72.4 N and 324.9±50.6 N, respectively (p=0.012). The mean stiffness for the separate vertical wiring technique and the combined technique was 241.1±68.5 N/mm and 340.8±45.3 N/mm, respectively (p=0.012). In the clinical study, the mean clinical score at final follow-up was 28.1 points. Conclusion Augmentation of separate vertical wiring with cerclage wire provides enough strength for protected early exercise of the knee joint and uneventful healing. PMID:24719149
Inoue, Kenji; Okayama, Ryoko; Higa, Risako; Wakakura, Masato; Tomita, Goji
2012-01-01
Latanoprost 0.005% + timolol maleate 0.5% combined eyedrops were recently made available in Japan. We prospectively investigated the intraocular pressure (IOP)-lowering effect, visual preservation effect, and adverse reactions of a one-year administration of this fixed combination. The subjects included 162 eyes from 162 patients diagnosed with either primary open-angle glaucoma or ocular hypertension and using an unfixed combination of latanoprost 0.005% and timolol maleate 0.5%. The unfixed combination was discontinued and replaced with the latanoprost 0.005% + timolol maleate 0.5% fixed combination with no washout period. IOP was measured before (baseline) and 3, 6, 9, and 12 months after the change. The mean deviation value of Humphrey field analysis was compared. Adverse reactions were examined at every follow-up. No significant differences were found between mean IOP values obtained at baseline (mean ± standard deviation, 15.2 ± 3.3 mmHg) 3 months (15.1 ± 3.2 mmHg), 6 months (15.3 ± 3.1 mmHg), 9 months (15.3 ± 3.1 mmHg), and 12 months (15.1 ± 3.2 mmHg) after the change from the unfixed to the fixed combination of eyedrops (P = 0.212). In addition, no significant differences were observed between mean deviation values obtained at baseline (-9.11 ± 6.94 dB) and 12 months (-10.08 ± 7.24 dB) after the change (P = 0.114). Thirty-one patients discontinued the fixed combination within 12 months of replacement, due to an insufficient IOP decrease (20 patients, 12.3%) and adverse reactions (11 patients, 6.8%). Following replacement of two eyedrop medications (latanoprost 0.005% and timolol maleate 0.5%) by one fixed combination (latanoprost 0.005% + timolol maleate 0.5%), IOP and visual field were preserved. However, 20% of the patients discontinued the new treatment because of an insufficient IOP decrease and complaints of adverse reactions.
Reliability of High-Temperature Fixed-Point Installations over 8 Years
NASA Astrophysics Data System (ADS)
Elliott, C. J.; Ford, T.; Ongrai, O.; Pearce, J. V.
2017-12-01
At NPL, high-temperature metal-carbon eutectic fixed points have been set up for thermocouple calibration purposes since 2006, for realising reference temperatures above the highest point specified in the International Temperature Scale of 1990 for contact thermometer calibrations. Additionally, cells of the same design have been provided by NPL to other national measurement institutes (NMIs) and calibration laboratories over this period, creating traceable and ISO 17025 accredited facilities around the world for calibrating noble metal thermocouples at 1324 {°}C (Co-C) and 1492 {°}C (Pd-C). This paper shows collections of thermocouple calibration results obtained during use of the high-temperature fixed-point cells at NPL and, as further examples, the use of cells installed at CCPI Europe (UK) and NIMT (Thailand). The lifetime of the cells can now be shown to be in excess of 7 years, whether used on a weekly or monthly basis, and whether used in an NMI or industrial calibration laboratory.
Upper bound on the Abelian gauge coupling from asymptotic safety
NASA Astrophysics Data System (ADS)
Eichhorn, Astrid; Versteegen, Fleur
2018-01-01
We explore the impact of asymptotically safe quantum gravity on the Abelian gauge coupling in a model including a charged scalar, confirming indications that asymptotically safe quantum fluctuations of gravity could trigger a power-law running towards a free fixed point for the gauge coupling above the Planck scale. Simultaneously, quantum gravity fluctuations balance against matter fluctuations to generate an interacting fixed point, which acts as a boundary of the basin of attraction of the free fixed point. This enforces an upper bound on the infrared value of the Abelian gauge coupling. In the regime of gravity couplings which in our approximation also allows for a prediction of the top quark and Higgs mass close to the experimental value [1], we obtain an upper bound approximately 35% above the infrared value of the hypercharge coupling in the Standard Model.
The computational core and fixed point organization in Boolean networks
NASA Astrophysics Data System (ADS)
Correale, L.; Leone, M.; Pagnani, A.; Weigt, M.; Zecchina, R.
2006-03-01
In this paper, we analyse large random Boolean networks in terms of a constraint satisfaction problem. We first develop an algorithmic scheme which allows us to prune simple logical cascades and underdetermined variables, returning thereby the computational core of the network. Second, we apply the cavity method to analyse the number and organization of fixed points. We find in particular a phase transition between an easy and a complex regulatory phase, the latter being characterized by the existence of an exponential number of macroscopically separated fixed point clusters. The different techniques developed are reinterpreted as algorithms for the analysis of single Boolean networks, and they are applied in the analysis of and in silico experiments on the gene regulatory networks of baker's yeast (Saccharomyces cerevisiae) and the segment-polarity genes of the fruitfly Drosophila melanogaster.
Fixed points, stable manifolds, weather regimes, and their predictability
Deremble, Bruno; D'Andrea, Fabio; Ghil, Michael
2009-10-27
In a simple, one-layer atmospheric model, we study the links between low-frequency variability and the model’s fixed points in phase space. The model dynamics is characterized by the coexistence of multiple ''weather regimes.'' To investigate the transitions from one regime to another, we focus on the identification of stable manifolds associated with fixed points. We show that these manifolds act as separatrices between regimes. We track each manifold by making use of two local predictability measures arising from the meteorological applications of nonlinear dynamics, namely, ''bred vectors'' and singular vectors. These results are then verified in the framework of ensemblemore » forecasts issued from clouds (ensembles) of initial states. The divergence of the trajectories allows us to establish the connections between zones of low predictability, the geometry of the stable manifolds, and transitions between regimes.« less
Fixed points, stable manifolds, weather regimes, and their predictability.
Deremble, Bruno; D'Andrea, Fabio; Ghil, Michael
2009-12-01
In a simple, one-layer atmospheric model, we study the links between low-frequency variability and the model's fixed points in phase space. The model dynamics is characterized by the coexistence of multiple "weather regimes." To investigate the transitions from one regime to another, we focus on the identification of stable manifolds associated with fixed points. We show that these manifolds act as separatrices between regimes. We track each manifold by making use of two local predictability measures arising from the meteorological applications of nonlinear dynamics, namely, "bred vectors" and singular vectors. These results are then verified in the framework of ensemble forecasts issued from "clouds" (ensembles) of initial states. The divergence of the trajectories allows us to establish the connections between zones of low predictability, the geometry of the stable manifolds, and transitions between regimes.
Cosmic infinity: a dynamical system approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bouhmadi-López, Mariam; Marto, João; Morais, João
2017-03-01
Dynamical system techniques are extremely useful to study cosmology. It turns out that in most of the cases, we deal with finite isolated fixed points corresponding to a given cosmological epoch. However, it is equally important to analyse the asymptotic behaviour of the universe. On this paper, we show how this can be carried out for 3-form models. In fact, we show that there are fixed points at infinity mainly by introducing appropriate compactifications and defining a new time variable that washes away any potential divergence of the system. The richness of 3-form models allows us as well to identifymore » normally hyperbolic non-isolated fixed points. We apply this analysis to three physically interesting situations: (i) a pre-inflationary era; (ii) an inflationary era; (iii) the late-time dark matter/dark energy epoch.« less
Recovery of Utility Fixed Costs: Utility, Consumer, Environmental and Economist Perspectives
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wood, Lisa; Hemphill, Ross; Howat, John
Utilities recover costs for providing electric service to retail customers through a combination of rate components that together comprise customers’ monthly electric bills. Rates and rate designs are set by state regulators and vary by jurisdiction, utility and customer class. In addition to the fundamental tenet of setting fair and reasonable rates, rate design balances economic efficiency, equity and fairness, customer satisfaction, utility revenue stability, and customer price and bill stability.1 At the most basic level, retail electricity bills in the United States typically include a fixed monthly customer charge — a set dollar amount regardless of energy usage —more » and a volumetric energy charge for each kilowatt-hour consumed.2 The energy charge may be flat across all hours, vary by usage level (for example, higher rates at higher levels of usage), or vary based on time of consumption.3 While some utility costs, such as fuel costs, clearly vary according to electricity usage, other costs are “fixed” over the short run — generally, those that do not vary over the course of a year. Depending on your point of view, and whether the state’s electricity industry has been restructured or remains vertically integrated, the set of costs that are “fixed” may be quite limited. Or the set may extend to all capacity costs for generation, transmission and distribution. In the long run, all costs are variable. In the context of flat or declining loads in some regions, utilities are proposing a variety of changes to retail rate designs, particularly for residential customers, to recover fixed costs. In this report, authors representing utility (Chapter 1), consumer (Chapter 2), environmentalist (Chapter 3) and economist (Chapter 4) perspectives discuss fixed costs for electric utilities and set out their principles for recovering those costs. The table on the next page summarizes each author’s relative preferences for various options for fixed cost recovery, some of which may be used in combination.4 The specific design of any ratemaking option matters crucially, so a general preference for a given option does not indicate support for any particular application.« less
Optimization of fixed-range trajectories for supersonic transport aircraft
NASA Astrophysics Data System (ADS)
Windhorst, Robert Dennis
1999-11-01
This thesis develops near-optimal guidance laws that generate minimum fuel, time, or direct operating cost fixed-range trajectories for supersonic transport aircraft. The approach uses singular perturbation techniques to time-scale de-couple the equations of motion into three sets of dynamics, two of which are analyzed in the main body of this thesis and one of which is analyzed in the Appendix. The two-point-boundary-value-problems obtained by application of the maximum principle to the dynamic systems are solved using the method of matched asymptotic expansions. Finally, the two solutions are combined using the matching principle and an additive composition rule to form a uniformly valid approximation of the full fixed-range trajectory. The approach is used on two different time-scale formulations. The first holds weight constant, and the second allows weight and range dynamics to propagate on the same time-scale. Solutions for the first formulation are only carried out to zero order in the small parameter, while solutions for the second formulation are carried out to first order. Calculations for a HSCT design were made to illustrate the method. Results show that the minimum fuel trajectory consists of three segments: a minimum fuel energy-climb, a cruise-climb, and a minimum drag glide. The minimum time trajectory also has three segments: a maximum dynamic pressure ascent, a constant altitude cruise, and a maximum dynamic pressure glide. The minimum direct operating cost trajectory is an optimal combination of the two. For realistic costs of fuel and flight time, the minimum direct operating cost trajectory is very similar to the minimum fuel trajectory. Moreover, the HSCT has three local optimum cruise speeds, with the globally optimum cruise point at the highest allowable speed, if range is sufficiently long. The final range of the trajectory determines which locally optimal speed is best. Ranges of 500 to 6,000 nautical miles, subsonic and supersonic mixed flight, and varying fuel efficiency cases are analyzed. Finally, the payload-range curve of the HSCT design is determined.
COMBINING RATE-BASED AND CAP-AND-TRADE EMISSIONS POLICIES. (R828628)
Rate-based emissions policies (like tradable performance standards, TPS) fix average emissions intensity, while cap-and-trade (CAT) policies fix total emissions. This paper shows that unfettered trade between rate-based and cap-and-trade programs always raises combined emissio...
TARDEC FIXED HEEL POINT (FHP): DRIVER CAD ACCOMMODATION MODEL VERIFICATION REPORT
2017-11-09
SUPPLEMENTARY NOTES N/A 14. ABSTRACT Easy-to-use Computer-Aided Design (CAD) tools, known as accommodation models, are needed by the ground vehicle... designers when developing the interior workspace for the occupant. The TARDEC Fixed Heel Point (FHP): Driver CAD Accommodation Model described in this...is intended to provide the composite boundaries representing the body of the defined target design population, including posture prediction
G. J. Jordan; M. J. Ducey; J. H. Gove
2004-01-01
We present the results of a timed field trial comparing the bias characteristics and relative sampling efficiency of line-intersect, fixed-area, and point relascope sampling for downed coarse woody material. Seven stands in a managed northern hardwood forest in New Hampshire were inventoried. Significant differences were found among estimates in some stands, indicating...
On stability of fixed points and chaos in fractional systems.
Edelman, Mark
2018-02-01
In this paper, we propose a method to calculate asymptotically period two sinks and define the range of stability of fixed points for a variety of discrete fractional systems of the order 0<α<2. The method is tested on various forms of fractional generalizations of the standard and logistic maps. Based on our analysis, we make a conjecture that chaos is impossible in the corresponding continuous fractional systems.
Impurity Correction Techniques Applied to Existing Doping Measurements of Impurities in Zinc
NASA Astrophysics Data System (ADS)
Pearce, J. V.; Sun, J. P.; Zhang, J. T.; Deng, X. L.
2017-01-01
Impurities represent the most significant source of uncertainty in most metal fixed points used for the realization of the International Temperature Scale of 1990 (ITS-90). There are a number of different methods for quantifying the effect of impurities on the freezing temperature of ITS-90 fixed points, many of which rely on an accurate knowledge of the liquidus slope in the limit of low concentration. A key method of determining the liquidus slope is to measure the freezing temperature of a fixed-point material as it is progressively doped with a known amount of impurity. Recently, a series of measurements of the freezing and melting temperature of `slim' Zn fixed-point cells doped with Ag, Fe, Ni, and Pb were presented. Here, additional measurements of the Zn-X system are presented using Ga as a dopant, and the data (Zn-Ag, Zn-Fe, Zn-Ni, Zn-Pb, and Zn-Ga) have been re-analyzed to demonstrate the use of a fitting method based on Scheil solidification which is applied to both melting and freezing curves. In addition, the utility of the Sum of Individual Estimates method is explored with these systems in the context of a recently enhanced database of liquidus slopes of impurities in Zn in the limit of low concentration.
NASA Astrophysics Data System (ADS)
Wähmer, M.; Anhalt, K.; Hollandt, J.; Klein, R.; Taubert, R. D.; Thornagel, R.; Ulm, G.; Gavrilov, V.; Grigoryeva, I.; Khlevnoy, B.; Sapritsky, V.
2017-10-01
Absolute spectral radiometry is currently the only established primary thermometric method for the temperature range above 1300 K. Up to now, the ongoing improvements of high-temperature fixed points and their formal implementation into an improved temperature scale with the mise en pratique for the definition of the kelvin, rely solely on single-wavelength absolute radiometry traceable to the cryogenic radiometer. Two alternative primary thermometric methods, yielding comparable or possibly even smaller uncertainties, have been proposed in the literature. They use ratios of irradiances to determine the thermodynamic temperature traceable to blackbody radiation and synchrotron radiation. At PTB, a project has been established in cooperation with VNIIOFI to use, for the first time, all three methods simultaneously for the determination of the phase transition temperatures of high-temperature fixed points. For this, a dedicated four-wavelengths ratio filter radiometer was developed. With all three thermometric methods performed independently and in parallel, we aim to compare the potential and practical limitations of all three methods, disclose possibly undetected systematic effects of each method and thereby confirm or improve the previous measurements traceable to the cryogenic radiometer. This will give further and independent confidence in the thermodynamic temperature determination of the high-temperature fixed point's phase transitions.
Permitted and forbidden sets in symmetric threshold-linear networks.
Hahnloser, Richard H R; Seung, H Sebastian; Slotine, Jean-Jacques
2003-03-01
The richness and complexity of recurrent cortical circuits is an inexhaustible source of inspiration for thinking about high-level biological computation. In past theoretical studies, constraints on the synaptic connection patterns of threshold-linear networks were found that guaranteed bounded network dynamics, convergence to attractive fixed points, and multistability, all fundamental aspects of cortical information processing. However, these conditions were only sufficient, and it remained unclear which were the minimal (necessary) conditions for convergence and multistability. We show that symmetric threshold-linear networks converge to a set of attractive fixed points if and only if the network matrix is copositive. Furthermore, the set of attractive fixed points is nonconnected (the network is multiattractive) if and only if the network matrix is not positive semidefinite. There are permitted sets of neurons that can be coactive at a stable steady state and forbidden sets that cannot. Permitted sets are clustered in the sense that subsets of permitted sets are permitted and supersets of forbidden sets are forbidden. By viewing permitted sets as memories stored in the synaptic connections, we provide a formulation of long-term memory that is more general than the traditional perspective of fixed-point attractor networks. There is a close correspondence between threshold-linear networks and networks defined by the generalized Lotka-Volterra equations.
A new approach to blind deconvolution of astronomical images
NASA Astrophysics Data System (ADS)
Vorontsov, S. V.; Jefferies, S. M.
2017-05-01
We readdress the strategy of finding approximate regularized solutions to the blind deconvolution problem, when both the object and the point-spread function (PSF) have finite support. Our approach consists in addressing fixed points of an iteration in which both the object x and the PSF y are approximated in an alternating manner, discarding the previous approximation for x when updating x (similarly for y), and considering the resultant fixed points as candidates for a sensible solution. Alternating approximations are performed by truncated iterative least-squares descents. The number of descents in the object- and in the PSF-space play a role of two regularization parameters. Selection of appropriate fixed points (which may not be unique) is performed by relaxing the regularization gradually, using the previous fixed point as an initial guess for finding the next one, which brings an approximation of better spatial resolution. We report the results of artificial experiments with noise-free data, targeted at examining the potential capability of the technique to deconvolve images of high complexity. We also show the results obtained with two sets of satellite images acquired using ground-based telescopes with and without adaptive optics compensation. The new approach brings much better results when compared with an alternating minimization technique based on positivity-constrained conjugate gradients, where the iterations stagnate when addressing data of high complexity. In the alternating-approximation step, we examine the performance of three different non-blind iterative deconvolution algorithms. The best results are provided by the non-negativity-constrained successive over-relaxation technique (+SOR) supplemented with an adaptive scheduling of the relaxation parameter. Results of comparable quality are obtained with steepest descents modified by imposing the non-negativity constraint, at the expense of higher numerical costs. The Richardson-Lucy (or expectation-maximization) algorithm fails to locate stable fixed points in our experiments, due apparently to inappropriate regularization properties.
[Formulation of technical specification for national survey of Chinese materia medica resources].
Guo, Lan-Ping; Lu, Jian-Wei; Zhang, Xiao-Bo; Zhao, Run-Huai; Zhang, Ben-Gang; Sun, Li-Ying; Huang, Lu-Qi
2013-04-01
According to the process of the technical specification (TS) design for the fourth national survey of the Chinese materia medica resources (CMMR), we analyzed the assignment and objectives of the national survey and pointed out that the differences about CMMR management around China, the distribution of CMMR and their habitat, the economic and technological level, and even enthusiasm and initiative of the staff, etc. are the most difficult points for TS design. And we adopt the principle of combination of the mandatory and flexibility in TS design. We fixed the key points which would affect the quality of national survey first, then proposed the framework of TS which including 3 parts of organization and 11 parts of technique itself. The framework will serve and lead the TS preparation, which will not only provide an action standard to the national survey but will also have a profound influence to the popularization and application of the survey technology of CMMR. [Key words
Laser-Induced Melting of Co-C Eutectic Cells as a New Research Tool
NASA Astrophysics Data System (ADS)
van der Ham, E.; Ballico, M.; Jahan, F.
2015-08-01
A new laser-based technique to examine heat transfer and energetics of phase transitions in metal-carbon fixed points and potentially to improve the quality of phase transitions in furnaces with poor uniformity is reported. Being reproducible below 0.1 K, metal-carbon fixed points are increasingly used as reference standards for the calibration of thermocouples and radiation thermometers. At NMIA, the Co-C eutectic point is used for the calibration of thermocouples, with the fixed point traceable to the International Temperature Scale (ITS-90) using radiation thermometry. For thermocouple use, these cells are deep inside a high-uniformity furnace, easily obtaining excellent melting plateaus. However, when used with radiation thermometers, the essential large viewing cone to the crucible restricts the furnace depth and introduces large heat losses from the front furnace zone, affecting the quality of the phase transition. Short laser bursts have been used to illuminate the cavity of a conventional Co-C fixed-point cell during various points in its melting phase transition. The laser is employed to partially melt the metal at the rear of the crucible providing a liquid-solid interface close to the region being observed by the reference pyrometer. As the laser power is known, a quantitative estimate of can be made for the Co-C latent heat of fusion. Using a single laser pulse during a furnace-induced melt, a plateau up to 8 min is observed before the crucible resumes a characteristic conventional melt curve. Although this plateau is satisfyingly flat, well within 100 mK, it is observed that the plateau is laser energy dependent and elevates from the conventional melt "inflection-point" value.
Lima, Glaura C; Silva, Emilia V; Magalhães, Pérola de O; Naves, Janeth S
Tuberculosis, particularly multi-drug-resistant tuberculosis, is a major cause of morbidity and mortality worldwide. To the best of our knowledge, however, no study to date has assessed the combined use of the four available drugs for tuberculosis treatment, which is an issue of great clinical relevance. To determine whether the four-drug fixed-dose combination is safer or more effective than separate drugs for treatment of pulmonary tuberculosis. A systematic review of the literature was performed in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. In pooled results from five randomized controlled trials with 3502 patients across Africa, Asia, and Latin America, four-drug fixed-dose combination therapy was no better than separate drugs therapy in terms of culture conversion after 2 and 6 months of treatment. There were no significant differences between the groups in overall incidence of adverse effects. However, the meta-analytic measure (log odds ratio) revealed that separate drugs treatment had a 1.65 [exp (0.5)=1.65] increased chance of gastrointestinal adverse effects compared to four-drug fixed-dose combination treatment. The reviewed studies showed that four-drug fixed-dose combination therapy provides greater patient comfort by reducing the number of pills and the incidence of gastrointestinal adverse effects, as well as simplifying pharmaceutical management at all levels. Copyright © 2016 Sociedade Brasileira de Microbiologia. Published by Elsevier Editora Ltda. All rights reserved.
ON THE DYNAMICS AND TIDAL DISSIPATION RATE OF THE WHITE DWARF IN 4U 1820-30
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prodan, Snezana; Murray, Norman, E-mail: sprodan@cita.utoronto.ca
It has been suggested that the 170 day period in the light curve of the low-mass X-ray binary 4U 1820-30 arises from the presence of a third body with a large inclination to the binary orbit. We show that this long-period motion arises if the system is librating around the stable fixed point in a Kozai resonance. We demonstrate that mass transfer drives the system toward this fixed point and calculate, both analytically and via numerical integrations, that the period of libration is of order 170 days when the mutual inclination is near the Kozai critical value. The non-zero eccentricitymore » of the binary, combined with tidal dissipation, implies that the rate of change of the binary period would be slower than, or even of opposite sign to, that implied by standard mass transfer models. If the 170 day period results from libration, then, contrary to appearances, the orbital period of the inner binary is increasing with time; in that case, (e/0.009){sup 2} Q/k{sub 2} {approx}> 2.5 Multiplication-Sign 10{sup 9}, where k{sub 2} Almost-Equal-To 0.01 is the tidal Love number and e = 0.009 is the fiducial eccentricity of the inner binary. It appears unlikely that the observed negative period derivative results from the smaller than expected (but positive) value of P-dot combined with the previously suggested acceleration of the system in the gravitational field of the host globular cluster NGC 6624. The discrepancy between the observed and the expected period derivative requires further investigation.« less
NASA Astrophysics Data System (ADS)
Dermíšek, Radovan; McGinnis, Navin
2018-03-01
We use the IR fixed point predictions for gauge couplings and the top Yukawa coupling in the minimal supersymmetric model (MSSM) extended with vectorlike families to infer the scale of vectorlike matter and superpartners. We quote results for several extensions of the MSSM and present results in detail for the MSSM extended with one complete vectorlike family. We find that for a unified gauge coupling αG>0.3 vectorlike matter or superpartners are expected within 1.7 TeV (2.5 TeV) based on all three gauge couplings being simultaneously within 1.5% (5%) from observed values. This range extends to about 4 TeV for αG>0.2 . We also find that in the scenario with two additional large Yukawa couplings of vectorlike quarks the IR fixed point value of the top Yukawa coupling independently points to a multi-TeV range for vectorlike matter and superpartners. Assuming a universal value for all large Yukawa couplings at the grand unified theory scale, the measured top quark mass can be obtained from the IR fixed point for tan β ≃4 . The range expands to any tan β >3 for significant departures from the universality assumption. Considering that the Higgs boson mass also points to a multi-TeV range for superpartners in the MSSM, adding a complete vectorlike family at the same scale provides a compelling scenario where the values of gauge couplings and the top quark mass are understood as a consequence of the particle content of the model.
Modeling of in-use stability for tablets and powders in bottles.
Waterman, Kenneth C; Chen, Lili; Waterman, Philip; MacDonald, Bruce C; Monahan, Andrew P; Scrivens, Garry
2016-10-01
A model is presented for determining the time when an active pharmaceutical ingredient in tablets/powders will remain within its specification limits during an in-use period; that is, when a heat-induction sealed bottle is opened for fixed time periods and where tablets are removed at fixed time points. This model combines the Accelerated Stability Assessment Program to determine the impact on degradation rates of relative humidity (RH) with calculations of the RH as a function of time for the dosage forms under in-use conditions. These calculations, in a conservative approach, assume that the air inside bottles with broached heat-induction seals completely exchanges with the external environment during periods when the bottle remains open. The solid dosages are assumed to sorb water at estimable rates during these openings. When bottles are capped, the moisture vapor transmission rate can be estimated to determine the changing RH inside the bottles between opening events. The impact of silica gel desiccants can also be included in the modeling.
Robust Control Design via Linear Programming
NASA Technical Reports Server (NTRS)
Keel, L. H.; Bhattacharyya, S. P.
1998-01-01
This paper deals with the problem of synthesizing or designing a feedback controller of fixed dynamic order. The closed loop specifications considered here are given in terms of a target performance vector representing a desired set of closed loop transfer functions connecting various signals. In general these point targets are unattainable with a fixed order controller. By enlarging the target from a fixed point set to an interval set the solvability conditions with a fixed order controller are relaxed and a solution is more easily enabled. Results from the parametric robust control literature can be used to design the interval target family so that the performance deterioration is acceptable, even when plant uncertainty is present. It is shown that it is possible to devise a computationally simple linear programming approach that attempts to meet the desired closed loop specifications.
Nebivolol and valsartan as a fixed-dose combination for the treatment of hypertension.
Sander, Gary E; Giles, Thomas D
2015-04-01
The fixed-dose combination of nebivolol and valsartan drug has been clinically evaluated and demonstrated to represent a unique combination of nebivolol, a selective β1-adrenoceptor antagonist and a β3-adrenoceptor agonist; β3 receptor activation increases endothelial nitric oxide and produces vasodilation. Valsartan is highly selective angiotensin AT1 receptor blocker and exerts its major pharmacological effect by decreasing angiotensin II-induced vasoconstriction and production of aldosterone. The addition of nebivolol counteracts the effects of increased angiotensin II concentrations resulting from potent AT1 blockade. This review describes a recently completed trial establishing the efficacy of the nebivolol/valsartan combination. This review provides a literature search of pertinent pharmacological and clinical data that describes the mechanisms of both drugs individually and the results of a clinical trial comparing fixed-dose combinations of nebivolol with valsartan as compared with each drug as monotherapy. Fixed-dose combination drugs are intended to improve patient compliance and reduce drug costs, as well as to reduce long-term cardiovascular event rates and block counter-regulatory effects due to monotherapy. The vast majority of hypertensive patients will require at least two medications. We believe that the clinical evidence suggests that the combination of nebivolol with valsartan offers a definite clinical benefit, combining β1-adrenoceptor and angiotensin AT1 receptor blockade with β3 receptor activation and resultant increase in nitric oxide and vasodilation.
Combining Heterogeneous Correlation Matrices: Simulation Analysis of Fixed-Effects Methods
ERIC Educational Resources Information Center
Hafdahl, Adam R.
2008-01-01
Monte Carlo studies of several fixed-effects methods for combining and comparing correlation matrices have shown that two refinements improve estimation and inference substantially. With rare exception, however, these simulations have involved homogeneous data analyzed using conditional meta-analytic procedures. The present study builds on…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morin, T. H.; Bohrer, G.; Stefanik, K. C.
Methane (CH 4) emissions and carbon uptake in temperate freshwater wetlands act in opposing directions in the context of global radiative forcing. Large uncertainties exist for the rates of CH 4 emissions making it difficult to determine the extent that CH 4 emissions counteract the carbon sequestration of wetlands. Urban temperate wetlands are typically small and feature highly heterogeneous land cover, posing an additional challenge to determining their CH 4 budget. The data analysis approach we introduce here combines two different CH 4 flux measurement techniques to overcome scale and heterogeneity problems and determine the overall CH 4 budget ofmore » a small, heterogeneous, urban wetland landscape. Temporally intermittent point measurements from non-steady-state chambers provided information about patch-level heterogeneity of fluxes, while continuous, high temporal resolution flux measurements using the eddy-covariance (EC) technique provided information about the temporal dynamics of the fluxes. Patch-level scaling parameterization was developed from the chamber data to scale eddy covariance data to a ‘fixed-frame’, which corrects for variability in the spatial coverage of the eddy covariance observation footprint at any single point in time. Finally, by combining two measurement techniques at different scales, we addressed shortcomings of both techniques with respect to heterogeneous wetland sites.« less
Morin, T. H.; Bohrer, G.; Stefanik, K. C.; ...
2017-02-17
Methane (CH 4) emissions and carbon uptake in temperate freshwater wetlands act in opposing directions in the context of global radiative forcing. Large uncertainties exist for the rates of CH 4 emissions making it difficult to determine the extent that CH 4 emissions counteract the carbon sequestration of wetlands. Urban temperate wetlands are typically small and feature highly heterogeneous land cover, posing an additional challenge to determining their CH 4 budget. The data analysis approach we introduce here combines two different CH 4 flux measurement techniques to overcome scale and heterogeneity problems and determine the overall CH 4 budget ofmore » a small, heterogeneous, urban wetland landscape. Temporally intermittent point measurements from non-steady-state chambers provided information about patch-level heterogeneity of fluxes, while continuous, high temporal resolution flux measurements using the eddy-covariance (EC) technique provided information about the temporal dynamics of the fluxes. Patch-level scaling parameterization was developed from the chamber data to scale eddy covariance data to a ‘fixed-frame’, which corrects for variability in the spatial coverage of the eddy covariance observation footprint at any single point in time. Finally, by combining two measurement techniques at different scales, we addressed shortcomings of both techniques with respect to heterogeneous wetland sites.« less
78 FR 57472 - IFR Altitudes; Miscellaneous Amendments
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-19
... BORDER DUNKIRK, NY VORTAC 18000 45000 DUNKIRK, NY VORTAC MTCAF, PA FIX 31000 45000 MTCAF, PA FIX LAKE... DUNKIRK, NY VORTAC 18000 45000 Airway segment Changeover points From To Distance From Sec. 95.8003 VOR...
Multiple positive solutions for a class of integral inclusions
NASA Astrophysics Data System (ADS)
Hong, Shihuang
2008-04-01
This paper deals with sufficient conditions for the existence of at least two positive solutions for a class of integral inclusions arising in the traffic theory. To show our main results, we apply a norm-type expansion and compression fixed point theorem for multivalued map due to Agarwal and O'Regan [A note on the existence of multiple fixed points for multivalued maps with applications, J. Differential Equation 160 (2000) 389-403].
NASA Astrophysics Data System (ADS)
Storti, Mario A.; Nigro, Norberto M.; Paz, Rodrigo R.; Dalcín, Lisandro D.
2009-03-01
In this paper some results on the convergence of the Gauss-Seidel iteration when solving fluid/structure interaction problems with strong coupling via fixed point iteration are presented. The flow-induced vibration of a flat plate aligned with the flow direction at supersonic Mach number is studied. The precision of different predictor schemes and the influence of the partitioned strong coupling on stability is discussed.
Compendium of Applications Technology Satellite user experiments
NASA Technical Reports Server (NTRS)
Engler, N. A.; Strange, J. D.; Hein, G. F.
1976-01-01
The achievements of the user experiments performed with ATS satellites from 1967 to 1973 are summarized. Included are fixed and mobile point to point communications experiments involving voice, teletype and facsimile transmissions. Particular emphasis is given to the Alaska and Hawaii satellite communications experiments. The use of the ATS satellites for ranging and position fixing of ships and aircraft is also covered. The structure and operating characteristics of the various ATS satellite are briefly described.
Scale-chiral symmetry, ω meson, and dense baryonic matter
NASA Astrophysics Data System (ADS)
Ma, Yong-Liang; Rho, Mannque
2018-05-01
It is shown that explicitly broken scale symmetry is essential for dense skyrmion matter in hidden local symmetry theory. Consistency with the vector manifestation fixed point for the hidden local symmetry of the lowest-lying vector mesons and the dilaton limit fixed point for scale symmetry in dense matter is found to require that the anomalous dimension (|γG2| ) of the gluon field strength tensor squared (G2 ) that represents the quantum trace anomaly should be 1.0 ≲|γG2|≲3.5 . The magnitude of |γG2| estimated here will be useful for studying hadron and nuclear physics based on the scale-chiral effective theory. More significantly, that the dilaton limit fixed point can be arrived at with γG2≠0 at some high density signals that scale symmetry can arise in dense medium as an "emergent" symmetry.
Quantization improves stabilization of dynamical systems with delayed feedback
NASA Astrophysics Data System (ADS)
Stepan, Gabor; Milton, John G.; Insperger, Tamas
2017-11-01
We show that an unstable scalar dynamical system with time-delayed feedback can be stabilized by quantizing the feedback. The discrete time model corresponds to a previously unrecognized case of the microchaotic map in which the fixed point is both locally and globally repelling. In the continuous-time model, stabilization by quantization is possible when the fixed point in the absence of feedback is an unstable node, and in the presence of feedback, it is an unstable focus (spiral). The results are illustrated with numerical simulation of the unstable Hayes equation. The solutions of the quantized Hayes equation take the form of oscillations in which the amplitude is a function of the size of the quantization step. If the quantization step is sufficiently small, the amplitude of the oscillations can be small enough to practically approximate the dynamics around a stable fixed point.
Classification of attractors for systems of identical coupled Kuramoto oscillators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Engelbrecht, Jan R.; Mirollo, Renato
2014-03-15
We present a complete classification of attractors for networks of coupled identical Kuramoto oscillators. In such networks, each oscillator is driven by the same first-order trigonometric function, with coefficients given by symmetric functions of the entire oscillator ensemble. For N≠3 oscillators, there are four possible types of attractors: completely synchronized fixed points or limit cycles, and fixed points or limit cycles where all but one of the oscillators are synchronized. The case N = 3 is exceptional; systems of three identical Kuramoto oscillators can also posses attracting fixed points or limit cycles with all three oscillators out of sync, as well asmore » chaotic attractors. Our results rely heavily on the invariance of the flow for such systems under the action of the three-dimensional group of Möbius transformations, which preserve the unit disc, and the analysis of the possible limiting configurations for this group action.« less
UV conformal window for asymptotic safety
NASA Astrophysics Data System (ADS)
Bond, Andrew D.; Litim, Daniel F.; Vazquez, Gustavo Medina; Steudtner, Tom
2018-02-01
Interacting fixed points in four-dimensional gauge theories coupled to matter are investigated using perturbation theory up to three loop order. It is shown how fixed points, scaling exponents, and anomalous dimensions are obtained as a systematic power series in a small parameter. The underlying ordering principle is explained and contrasted with conventional perturbation theory and Weyl consistency conditions. We then determine the conformal window with asymptotic safety from the complete next-to-next-to-leading order in perturbation theory. Limits for the conformal window arise due to fixed point mergers, the onset of strong coupling, or vacuum instability. A consistent picture is uncovered by comparing various levels of approximation. The theory remains perturbative in the entire conformal window, with vacuum stability dictating the tightest constraints. We also speculate about a secondary conformal window at strong coupling and estimate its lower limit. Implications for model building and cosmology are indicated.
A Machine-Checked Proof of A State-Space Construction Algorithm
NASA Technical Reports Server (NTRS)
Catano, Nestor; Siminiceanu, Radu I.
2010-01-01
This paper presents the correctness proof of Saturation, an algorithm for generating state spaces of concurrent systems, implemented in the SMART tool. Unlike the Breadth First Search exploration algorithm, which is easy to understand and formalise, Saturation is a complex algorithm, employing a mutually-recursive pair of procedures that compute a series of non-trivial, nested local fixed points, corresponding to a chaotic fixed point strategy. A pencil-and-paper proof of Saturation exists, but a machine checked proof had never been attempted. The key element of the proof is the characterisation theorem of saturated nodes in decision diagrams, stating that a saturated node represents a set of states encoding a local fixed-point with respect to firing all events affecting only the node s level and levels below. For our purpose, we have employed the Prototype Verification System (PVS) for formalising the Saturation algorithm, its data structures, and for conducting the proofs.
Gravity Duals of Lifshitz-Like Fixed Points
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kachru, Shamit; /Stanford U., Phys. Dept. /SLAC; Liu, Xiao
2008-11-05
We find candidate macroscopic gravity duals for scale-invariant but non-Lorentz invariant fixed points, which do not have particle number as a conserved quantity. We compute two-point correlation functions which exhibit novel behavior relative to their AdS counterparts, and find holographic renormalization group flows to conformal field theories. Our theories are characterized by a dynamical critical exponent z, which governs the anisotropy between spatial and temporal scaling t {yields} {lambda}{sup z}t, x {yields} {lambda}x; we focus on the case with z = 2. Such theories describe multicritical points in certain magnetic materials and liquid crystals, and have been shown to arisemore » at quantum critical points in toy models of the cuprate superconductors. This work can be considered a small step towards making useful dual descriptions of such critical points.« less
1944-07-12
of tall area tlaes tall length are nearly the same. The airplane eas stable, « tick fixed, In all condi- tions except vave-off *lth the center of...in all conditions •icept aeve.off. A table of neutral points, both stick free end « tick flaed. for the XSBA-1 airplane «1th tall -it.figuration...I follostai Condition Ct Keutral point, Neutral point. • tick fixed •tlek free illding Cruising Cllablnc Landing approach •eve.off C.« 1.0
Field programmable gate array-assigned complex-valued computation and its limits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bernard-Schwarz, Maria, E-mail: maria.bernardschwarz@ni.com; Institute of Applied Physics, TU Wien, Wiedner Hauptstrasse 8, 1040 Wien; Zwick, Wolfgang
We discuss how leveraging Field Programmable Gate Array (FPGA) technology as part of a high performance computing platform reduces latency to meet the demanding real time constraints of a quantum optics simulation. Implementations of complex-valued operations using fixed point numeric on a Virtex-5 FPGA compare favorably to more conventional solutions on a central processing unit. Our investigation explores the performance of multiple fixed point options along with a traditional 64 bits floating point version. With this information, the lowest execution times can be estimated. Relative error is examined to ensure simulation accuracy is maintained.
Report on NIM-NMC bilateral comparison: SPRT calibration comparison from -190°C to 420°C
NASA Astrophysics Data System (ADS)
Sun, Jianping; Ye, Shaochun; Wang, Li; Zhang, Jintao; Kho, Haoyuan
2016-01-01
A bilateral comparison of local realization of the International temperature scale of 1990 (ITS-90) between National Institute of Metrology (NIM) and National Metrology Centre (NMC) was carried out over the temperature range from -190°C to 420°C. It involved six fixed points including the argon triple point, the mercury triple point, the triple point of water, the melting point of gallium, the freezing point of tin and the freezing point of zinc. In 2009, NMC asked NIM to participate in a bilateral comparison to link the NMC results to the Consultative Committee for Thermometry Key comparison 3 (CCT-K3) and facilitate the NMC's Calibration and measurement capabilities (CMCs) submission. This comparison was agreed by NIM and Asia Pacific Metrology Programme (APMP) in 2009, and registered in the Key Comparison Database (KCDB) in 2010 as CCT-K3.2. NMC supplied two 25 Ω fused silica sheath standard platinum resistance thermometers (SPRTs) as traveling standards. One of them was used at the Ga, Sn and Zn fixed points, while the other one was used at the Ar and Hg fixed point. NMC measured them before and after NIM measurement. During the comparison, a criterion for the SPRT was set as the stability at the triple point of water to be less than 0.3 mK. The results for both laboratories are summarized. A proposal for linking the NMC's comparison results to CCT-K3 is presented. The difference between NMC and NIM and the difference between NMC and the CCT-K3 Average Reference Value (ARV) using NIM as a link are reported with expanded uncertainties at each measured fixed point. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
NASA Astrophysics Data System (ADS)
Classen, Laura; Herbut, Igor F.; Janssen, Lukas; Scherer, Michael M.
2016-03-01
We study the competition of spin- and charge-density waves and their quantum multicritical behavior for the semimetal-insulator transitions of low-dimensional Dirac fermions. Employing the effective Gross-Neveu-Yukawa theory with two order parameters as a model for graphene and a growing number of other two-dimensional Dirac materials allows us to describe the physics near the multicritical point at which the semimetallic and the spin- and charge-density-wave phases meet. With the help of a functional renormalization group approach, we are able to reveal a complex structure of fixed points, the stability properties of which decisively depend on the number of Dirac fermions Nf. We give estimates for the critical exponents and observe crucial quantitative corrections as compared to the previous first-order ɛ expansion. For small Nf, the universal behavior near the multicritical point is determined by the chiral Heisenberg universality class supplemented by a decoupled, purely bosonic, Ising sector. At large Nf, a novel fixed point with nontrivial couplings between all sectors becomes stable. At intermediate Nf, including the graphene case (Nf=2 ), no stable and physically admissible fixed point exists. Graphene's phase diagram in the vicinity of the intersection between the semimetal, antiferromagnetic, and staggered density phases should consequently be governed by a triple point exhibiting first-order transitions.
Compatible orders and fermion-induced emergent symmetry in Dirac systems
NASA Astrophysics Data System (ADS)
Janssen, Lukas; Herbut, Igor F.; Scherer, Michael M.
2018-01-01
We study the quantum multicritical point in a (2+1)-dimensional Dirac system between the semimetallic phase and two ordered phases that are characterized by anticommuting mass terms with O (N1) and O (N2) symmetries, respectively. Using ɛ expansion around the upper critical space-time dimension of four, we demonstrate the existence of a stable renormalization-group fixed point, enabling a direct and continuous transition between the two ordered phases directly at the multicritical point. This point is found to be characterized by an emergent O (N1+N2) symmetry for arbitrary values of N1 and N2 and fermion flavor numbers Nf as long as the corresponding representation of the Clifford algebra exists. Small O (N ) -breaking perturbations near the chiral O (N ) fixed point are therefore irrelevant. This result can be traced back to the presence of gapless Dirac degrees of freedom at criticality, and it is in clear contrast to the purely bosonic O (N ) fixed point, which is stable only when N <3 . As a by-product, we obtain predictions for the critical behavior of the chiral O (N ) universality classes for arbitrary N and fermion flavor number Nf. Implications for critical Weyl and Dirac systems in 3+1 dimensions are also briefly discussed.
Charged fixed point in the Ginzburg-Landau superconductor and the role of the Ginzburg parameter /κ
NASA Astrophysics Data System (ADS)
Kleinert, Hagen; Nogueira, Flavio S.
2003-02-01
We present a semi-perturbative approach which yields an infrared-stable fixed point in the Ginzburg-Landau for N=2, where N/2 is the number of complex components. The calculations are done in d=3 dimensions and below Tc, where the renormalization group functions can be expressed directly as functions of the Ginzburg parameter κ which is the ratio between the two fundamental scales of the problem, the penetration depth λ and the correlation length ξ. We find a charged fixed point for κ>1/ 2, that is, in the type II regime, where Δκ≡κ-1/ 2 is shown to be a natural expansion parameter. This parameter controls a momentum space instability in the two-point correlation function of the order field. This instability appears at a non-zero wave-vector p0 whose magnitude scales like ˜ Δκ β¯, with a critical exponent β¯=1/2 in the one-loop approximation, a behavior known from magnetic systems with a Lifshitz point in the phase diagram. This momentum space instability is argued to be the origin of the negative η-exponent of the order field.
2012-01-01
A lumped model of neural activity in neocortex is studied to identify regions of multi-stability of both steady states and periodic solutions. Presence of both steady states and periodic solutions is considered to correspond with epileptogenesis. The model, which consists of two delay differential equations with two fixed time lags is mainly studied for its dependency on varying connection strength between populations. Equilibria are identified, and using linear stability analysis, all transitions are determined under which both trivial and non-trivial fixed points lose stability. Periodic solutions arising at some of these bifurcations are numerically studied with a two-parameter bifurcation analysis. PMID:22655859
Mean Field Games for Stochastic Growth with Relative Utility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Minyi, E-mail: mhuang@math.carleton.ca; Nguyen, Son Luu, E-mail: sonluu.nguyen@upr.edu
This paper considers continuous time stochastic growth-consumption optimization in a mean field game setting. The individual capital stock evolution is determined by a Cobb–Douglas production function, consumption and stochastic depreciation. The individual utility functional combines an own utility and a relative utility with respect to the population. The use of the relative utility reflects human psychology, leading to a natural pattern of mean field interaction. The fixed point equation of the mean field game is derived with the aid of some ordinary differential equations. Due to the relative utility interaction, our performance analysis depends on some ratio based approximation errormore » estimate.« less
Point of a space experiment proposal.
Fukui, Keiji; Shimazu, Toru; Higashibata, Akira; Fujimoto, Nobuyoshi; Ishioka, Noriaki
2003-10-01
JAXA will solicit research proposals for space flight experiments that would be conducted for less than three years after the selection. In principle, available samples will be limited to Arabidopsis and C. elegans and flight hardware and protocol of space flight experiment will be pre-fixed. Proposals using different combinations of species and flight hardware will not be acceptable. Besides scientific issues, it is very important for proposer to write an impressive proposal. Hypothesis basis research proposal is the accepted standard. Reviewers will dislike a descriptive and unfocused research proposal without hypothesis. Ground preparation experiments, which are not related directly to space experiments, should not be included in the solicitation.
A conserved quantity in thin body dynamics
NASA Astrophysics Data System (ADS)
Hanna, James; Pendar, Hodjat
We use an example from textile processing to illustrate the utility of a conserved quantity associated with metric symmetry in a thin body. This quantity, when combined with the usual linear and angular momentum currents, allows us to construct a four-parameter family of curves representing the equilibria of a rotating, flowing string. To achieve this, we introduce a non-material action of mixed Lagrangian-Eulerian type, applicable to fixed windows of axially-moving systems. We will point out intriguing similarities with Bernoulli's equation, discuss the effects of axial flow on rotating conservative systems, and make connections with 19th- and 20th-century results on the dynamics of cables.
A method of undifferenced ambiguity resolution for GPS+GLONASS precise point positioning
Yi, Wenting; Song, Weiwei; Lou, Yidong; Shi, Chuang; Yao, Yibin
2016-01-01
Integer ambiguity resolution is critical for achieving positions of high precision and for shortening the convergence time of precise point positioning (PPP). However, GLONASS adopts the signal processing technology of frequency division multiple access and results in inter-frequency code biases (IFCBs), which are currently difficult to correct. This bias makes the methods proposed for GPS ambiguity fixing unsuitable for GLONASS. To realize undifferenced GLONASS ambiguity fixing, we propose an undifferenced ambiguity resolution method for GPS+GLONASS PPP, which considers the IFCBs estimation. The experimental result demonstrates that the success rate of GLONASS ambiguity fixing can reach 75% through the proposed method. Compared with the ambiguity float solutions, the positioning accuracies of ambiguity-fixed solutions of GLONASS-only PPP are increased by 12.2%, 20.9%, and 10.3%, and that of the GPS+GLONASS PPP by 13.0%, 35.2%, and 14.1% in the North, East and Up directions, respectively. PMID:27222361
A method of undifferenced ambiguity resolution for GPS+GLONASS precise point positioning.
Yi, Wenting; Song, Weiwei; Lou, Yidong; Shi, Chuang; Yao, Yibin
2016-05-25
Integer ambiguity resolution is critical for achieving positions of high precision and for shortening the convergence time of precise point positioning (PPP). However, GLONASS adopts the signal processing technology of frequency division multiple access and results in inter-frequency code biases (IFCBs), which are currently difficult to correct. This bias makes the methods proposed for GPS ambiguity fixing unsuitable for GLONASS. To realize undifferenced GLONASS ambiguity fixing, we propose an undifferenced ambiguity resolution method for GPS+GLONASS PPP, which considers the IFCBs estimation. The experimental result demonstrates that the success rate of GLONASS ambiguity fixing can reach 75% through the proposed method. Compared with the ambiguity float solutions, the positioning accuracies of ambiguity-fixed solutions of GLONASS-only PPP are increased by 12.2%, 20.9%, and 10.3%, and that of the GPS+GLONASS PPP by 13.0%, 35.2%, and 14.1% in the North, East and Up directions, respectively.
Wu, Jiun-Ting; Chiu, Chien-Tung; Wei, Yu-Feng; Lai, Yung-Fa
2015-06-01
Fixed-dose combination formulations, which simplify the administration of drugs and prevent the development of drug resistance, have been recommended as a standard anti-tuberculosis treatment regimen. However, the composition and dosage recommendations for fixed-dose combination formulations differ from those for separate formulations. Thus, questions about the effectiveness and side effects of combination formulations remain. The aim of this study was to compare the safety and efficacy of these two types of anti-tuberculosis regimens for pulmonary tuberculosis treatment. A prospective, randomized controlled study was conducted using the directly observed treatment short-course strategy. Patients were randomly allocated to one of two short-course regimens. One year after completing the treatment, these patients' outcomes were analyzed. ClinicalTrials.gov: NCT00979290. A total of 161 patients were enrolled, 142 of whom were evaluable for safety assessment. The two regimens had a similar incidence of adverse effects. In the per-protocol population, serum bilirubin concentrations at the peak level, at week 4, and at week 8 were significantly higher for the fixed-dose combination formulation than for the separate formulations. All patients had negative sputum cultures at the end of the treatment, and no relapse occurred after one year of follow-up. In this randomized study, transient higher serum bilirubin levels were noted for the fixed-dose combination regimen compared with the separate formulations during treatment. However, no significant difference in safety or efficacy was found between the groups when the directly observed treatment short-course strategy was used.
Newell, Felicity L.; Sheehan, James; Wood, Petra Bohall; Rodewald, Amanda D.; Buehler, David A.; Keyser, Patrick D.; Larkin, Jeffrey L.; Beachy, Tiffany A.; Bakermans, Marja H.; Boves, Than J.; Evans, Andrea; George, Gregory A.; McDermott, Molly E.; Perkins, Kelly A.; White, Matthew; Wigley, T. Bently
2013-01-01
Point counts are commonly used to assess changes in bird abundance, including analytical approaches such as distance sampling that estimate density. Point-count methods have come under increasing scrutiny because effects of detection probability and field error are difficult to quantify. For seven forest songbirds, we compared fixed-radii counts (50 m and 100 m) and density estimates obtained from distance sampling to known numbers of birds determined by territory mapping. We applied point-count analytic approaches to a typical forest management question and compared results to those obtained by territory mapping. We used a before–after control impact (BACI) analysis with a data set collected across seven study areas in the central Appalachians from 2006 to 2010. Using a 50-m fixed radius, variance in error was at least 1.5 times that of the other methods, whereas a 100-m fixed radius underestimated actual density by >3 territories per 10 ha for the most abundant species. Distance sampling improved accuracy and precision compared to fixed-radius counts, although estimates were affected by birds counted outside 10-ha units. In the BACI analysis, territory mapping detected an overall treatment effect for five of the seven species, and effects were generally consistent each year. In contrast, all point-count methods failed to detect two treatment effects due to variance and error in annual estimates. Overall, our results highlight the need for adequate sample sizes to reduce variance, and skilled observers to reduce the level of error in point-count data. Ultimately, the advantages and disadvantages of different survey methods should be considered in the context of overall study design and objectives, allowing for trade-offs among effort, accuracy, and power to detect treatment effects.
Mcdonald, E; Theologis, A A; Horst, P; Kandemir, U; Pekmezci, M
2015-12-01
This study aimed at evaluating the additional stability that is provided by anterior external and internal fixators in an unstable pelvic fracture model (OTA 61-C). An unstable pelvic fracture (OTA 61-C) was created in 27 synthetic pelves by making a 5-mm gap through the sacral foramina (posterior injury) and an ipsilateral pubic rami fracture (anterior injury). The posterior injury was fixed with either a single iliosacral (IS) screw, a single trans-iliac, trans-sacral (TS) screw, or two iliosacral screws (S1S2). Two anterior fixation techniques were utilized: external fixation (Ex-Fix) and supra-acetabular external fixation and internal fixation (In-Fix); supra-acetabular pedicle screws connected with a single subcutaneous spinal rod. The specimens were tested using a nondestructive single-leg stance model. Peak-to-peak (P2P) displacement and rotation and conditioning displacement (CD) were calculated. The Ex-Fix group failed in 83.3 % of specimens with concomitant single-level posterior fixation (Total: 15/18-7 of 9 IS fixation, 8 of 9 TS fixation), and 0 % (0/9) of specimens with concomitant two-level (S1S2) posterior fixation. All specimens with the In-Fix survived testing except for two specimens treated with In-Fix combined with IS fixation. Trans-sacral fixation had higher pubic rotation and greater sacral and pubic displacement than S1S2 (p < 0.05). Rotation of the pubis and sacrum was not different between In-Fix constructs combined with single-level IS and TS fixation. In this model of an unstable pelvic fracture (OTA 61-C), anterior fixation with an In-Fix was biomechanically superior to an anterior Ex-Fix in the setting of single-level posterior fixation. There was no biomechanical difference between the In-Fix and Ex-Fix when each was combined with two levels of posterior sacral fixation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laurie, M.; Vlahovic, L.; Rondinella, V.V.
Temperature measurements in the nuclear field require a high degree of reliability and accuracy. Despite their sheathed form, thermocouples subjected to nuclear radiations undergo changes due to radiation damage and transmutation that lead to significant EMF drift during long-term fuel irradiation experiment. For the purpose of a High Temperature Reactor fuel irradiation to take place in the High Flux Reactor Petten, a dedicated fixed-point cell was jointly developed by LNE-Cnam and JRC-IET. The developed cell to be housed in the irradiation rig was tailor made to quantify the thermocouple drift during the irradiation (about two year duration) and withstand highmore » temperature (in the range 950 deg. C - 1100 deg. C) in the presence of contaminated helium in a graphite environment. Considering the different levels of temperature achieved in the irradiation facility and the large palette of thermocouple types aimed at surveying the HTR fuel pebble during the qualification test both copper (1084.62 deg. C) and gold (1064.18 deg. C) fixed-point materials were considered. The aim of this paper is to first describe the fixed-point mini-cell designed to be embedded in the reactor rig and to discuss the preliminary results achieved during some out of pile tests as much as some robustness tests representative of the reactor scram scenarios. (authors)« less
Small copper fixed-point cells of the hybrid type to be used in place of normal larger cells
NASA Astrophysics Data System (ADS)
Battuello, M.; Girard, F.; Florio, M.
2012-10-01
Two small cells for the realization of the fixed point of copper were constructed and investigated at INRIM. They are of the same hybrid design generally adopted for the eutectic high-temperature fixed-point cells, namely a structure with a sacrificial graphite sleeve and a layer of flexible carbon-carbon composite sheet (C/C sheet). Because of the largely different design with respect to the cells normally adopted for the construction of pure metal fixed points, they were compared and characterized with respect to the normal cells used at INRIM for the ITS-90 realization. Two different furnaces were used to compare hybrid and normal cells. One of the hybrid cells was also used in different configurations, i.e. without the C/C sheet and with two layers of sheet. The cells were compared with different operative conditions, i.e. temperature settings of the furnaces for inducing the freeze, and repeatability and reproducibility were investigated. Freezing temperature and shape of the plateaux obtained under the different conditions were analysed. As expected the duration of the plateaux obtained with the hybrid cells is considerably shorter than with the normal cell, but this does not affect the results in terms of freezing temperature. Measurements with the modified cell showed that the use of a double C/C sheet may improve both repeatability and reproducibility of the plateaux.
Eye Movements in Darkness Modulate Self-Motion Perception.
Clemens, Ivar Adrianus H; Selen, Luc P J; Pomante, Antonella; MacNeilage, Paul R; Medendorp, W Pieter
2017-01-01
During self-motion, humans typically move the eyes to maintain fixation on the stationary environment around them. These eye movements could in principle be used to estimate self-motion, but their impact on perception is unknown. We had participants judge self-motion during different eye-movement conditions in the absence of full-field optic flow. In a two-alternative forced choice task, participants indicated whether the second of two successive passive lateral whole-body translations was longer or shorter than the first. This task was used in two experiments. In the first ( n = 8), eye movements were constrained differently in the two translation intervals by presenting either a world-fixed or body-fixed fixation point or no fixation point at all (allowing free gaze). Results show that perceived translations were shorter with a body-fixed than a world-fixed fixation point. A linear model indicated that eye-movement signals received a weight of ∼25% for the self-motion percept. This model was independently validated in the trials without a fixation point (free gaze). In the second experiment ( n = 10), gaze was free during both translation intervals. Results show that the translation with the larger eye-movement excursion was judged more often to be larger than chance, based on an oculomotor choice probability analysis. We conclude that eye-movement signals influence self-motion perception, even in the absence of visual stimulation.
A Fixed Point VHDL Component Library for a High Efficiency Reconfigurable Radio Design Methodology
NASA Technical Reports Server (NTRS)
Hoy, Scott D.; Figueiredo, Marco A.
2006-01-01
Advances in Field Programmable Gate Array (FPGA) technologies enable the implementation of reconfigurable radio systems for both ground and space applications. The development of such systems challenges the current design paradigms and requires more robust design techniques to meet the increased system complexity. Among these techniques is the development of component libraries to reduce design cycle time and to improve design verification, consequently increasing the overall efficiency of the project development process while increasing design success rates and reducing engineering costs. This paper describes the reconfigurable radio component library developed at the Software Defined Radio Applications Research Center (SARC) at Goddard Space Flight Center (GSFC) Microwave and Communications Branch (Code 567). The library is a set of fixed-point VHDL components that link the Digital Signal Processing (DSP) simulation environment with the FPGA design tools. This provides a direct synthesis path based on the latest developments of the VHDL tools as proposed by the BEE VBDL 2004 which allows for the simulation and synthesis of fixed-point math operations while maintaining bit and cycle accuracy. The VHDL Fixed Point Reconfigurable Radio Component library does not require the use of the FPGA vendor specific automatic component generators and provide a generic path from high level DSP simulations implemented in Mathworks Simulink to any FPGA device. The access to the component synthesizable, source code provides full design verification capability:
Eye Movements in Darkness Modulate Self-Motion Perception
Pomante, Antonella
2017-01-01
Abstract During self-motion, humans typically move the eyes to maintain fixation on the stationary environment around them. These eye movements could in principle be used to estimate self-motion, but their impact on perception is unknown. We had participants judge self-motion during different eye-movement conditions in the absence of full-field optic flow. In a two-alternative forced choice task, participants indicated whether the second of two successive passive lateral whole-body translations was longer or shorter than the first. This task was used in two experiments. In the first (n = 8), eye movements were constrained differently in the two translation intervals by presenting either a world-fixed or body-fixed fixation point or no fixation point at all (allowing free gaze). Results show that perceived translations were shorter with a body-fixed than a world-fixed fixation point. A linear model indicated that eye-movement signals received a weight of ∼25% for the self-motion percept. This model was independently validated in the trials without a fixation point (free gaze). In the second experiment (n = 10), gaze was free during both translation intervals. Results show that the translation with the larger eye-movement excursion was judged more often to be larger than chance, based on an oculomotor choice probability analysis. We conclude that eye-movement signals influence self-motion perception, even in the absence of visual stimulation. PMID:28144623
NASA Astrophysics Data System (ADS)
Griffin, Christopher; Belmonte, Andrew
2017-05-01
We study the problem of stabilized coexistence in a three-species public goods game in which each species simultaneously contributes to one public good while freeloading off another public good ("cheating"). The proportional population growth is governed by an appropriately modified replicator equation, depending on the returns from the public goods and the cost. We show that the replicator dynamic has at most one interior unstable fixed point and that the population becomes dominated by a single species. We then show that by applying an externally imposed penalty, or "tax" on success can stabilize the interior fixed point, allowing for the symbiotic coexistence of all species. We show that the interior fixed point is the point of globally minimal total population growth in both the taxed and untaxed cases. We then formulate an optimal taxation problem and show that it admits a quasilinearization, resulting in novel necessary conditions for the optimal control. In particular, the optimal control problem governing the tax rate must solve a certain second-order ordinary differential equation.
Griffin, Christopher; Belmonte, Andrew
2017-05-01
We study the problem of stabilized coexistence in a three-species public goods game in which each species simultaneously contributes to one public good while freeloading off another public good ("cheating"). The proportional population growth is governed by an appropriately modified replicator equation, depending on the returns from the public goods and the cost. We show that the replicator dynamic has at most one interior unstable fixed point and that the population becomes dominated by a single species. We then show that by applying an externally imposed penalty, or "tax" on success can stabilize the interior fixed point, allowing for the symbiotic coexistence of all species. We show that the interior fixed point is the point of globally minimal total population growth in both the taxed and untaxed cases. We then formulate an optimal taxation problem and show that it admits a quasilinearization, resulting in novel necessary conditions for the optimal control. In particular, the optimal control problem governing the tax rate must solve a certain second-order ordinary differential equation.
Mutual information in the evolution of trajectories in discrete aiming movements.
Lai, Shih-Chiung; Mayer-Kress, Gottfried; Newell, Karl M
2008-07-01
This study investigated the mutual information in the trajectories of discrete aiming movements on a computer controlled graphics tablet where movement time ( 300 - 2050 ms) was manipulated in a given distance (100 mm) and movement distance (15-240 mm) in 2 given movement times (300 ms and 800 ms ). For the distance-fixed conditions, there was higher mutual information in the slower movements in the 0 vs. 80-100% trajectory point comparisons, whereas the mutual information was higher for the faster movements when comparing within the 80 and 100% points of the movement trajectory. For the time-fixed conditions, the spatial constraints led to a decreasing pattern of the mutual information throughout the points of the trajectory, with the highest mutual information found in the 80 vs. 100% comparison. Overall, the pattern of mutual information reveals systematic modulation of the trajectories between the attractive fixed point of the target as a function of movement condition. These mutual information patterns are postulated to be the consequence of the different relative contributions of feedforward and feedback control processes in trajectory formation as a function of task constraints.
Evolution and stability of altruist strategies in microbial games
NASA Astrophysics Data System (ADS)
Adami, Christoph; Schossau, Jory; Hintze, Arend
2012-01-01
When microbes compete for limited resources, they often engage in chemical warfare using bacterial toxins. This competition can be understood in terms of evolutionary game theory (EGT). We study the predictions of EGT for the bacterial “suicide bomber” game in terms of the phase portraits of population dynamics, for parameter combinations that cover all interesting games for two-players, and seven of the 38 possible phase portraits of the three-player game. We compare these predictions to simulations of these competitions in finite well-mixed populations, but also allowing for probabilistic rather than pure strategies, as well as Darwinian adaptation over tens of thousands of generations. We find that Darwinian evolution of probabilistic strategies stabilizes games of the rock-paper-scissors type that emerge for parameters describing realistic bacterial populations, and point to ways in which the population fixed point can be selected by changing those parameters.
Chondritic meteorites and the lunar surface.
O'keefe, J A; Scott, R F
1967-12-01
The landing dynamics of and soil penetration by Surveyor I indicated that the lunar soil has a porosity in the range 0.35 to 0.45. Experiments with Surveyor III's surface sampler for soil mechanics show that the lunar soil is approximately incompressible (as the word is used in soil mechanics) and that it has an angle of internal friction of 35 to 37 degrees; these results likewise point to a porosity of 0.35 to 0.45 for the lunar soil. Combination of these porosity measurements with the already-determined radar reflectivity fixes limits to the dielectric constant of the grains of the lunar soil. The highest possible value is about 5.9, relative to vacuum; a more plausible value is near 4.3. Either figure is inconsistent with the idea that the lunar surface is covered by chondritic meteorites or other ultrabasic rocks. The data point to acid rocks, or possibly vesicular basalts; carbonaceous chondrites are not excluded.
Monte Carlo Simulation of THz Multipliers
NASA Technical Reports Server (NTRS)
East, J.; Blakey, P.
1997-01-01
Schottky Barrier diode frequency multipliers are critical components in submillimeter and Thz space based earth observation systems. As the operating frequency of these multipliers has increased, the agreement between design predictions and experimental results has become poorer. The multiplier design is usually based on a nonlinear model using a form of harmonic balance and a model for the Schottky barrier diode. Conventional voltage dependent lumped element models do a poor job of predicting THz frequency performance. This paper will describe a large signal Monte Carlo simulation of Schottky barrier multipliers. The simulation is a time dependent particle field Monte Carlo simulation with ohmic and Schottky barrier boundary conditions included that has been combined with a fixed point solution for the nonlinear circuit interaction. The results in the paper will point out some important time constants in varactor operation and will describe the effects of current saturation and nonlinear resistances on multiplier operation.
Erosion and attrition of human enamel in vitro part II: influence of time and loading.
Eisenburger, M; Addy, M
2002-01-01
To determine the influence of load and time on enamel wear by attrition under neutral and acid environments in vitro. Groups of 10 enamel cusp and smooth surface specimens obtained from unerupted third molars were opposed in a wear machine under loads of 200, 400 and 600 g in citric acid at pH 3.2 and in physiological saline at 35 degrees C for 30 min (2280 wear cycles). The experiment was repeated with a load of 600 g for 10 and 20 min accompanied by 10 taped specimens to measure erosion only. Erosion and attrition of smooth surface specimens was determined by profilometry. At a load of 600 g attrition in saline increased with time from 7.9 microm (SD 3.7 microm) at 10 min, 10.2 microm (SD 4.8 microm) at 20-25.5 microm (SD 9.1 microm) after 30 min and combined attrition/erosion in citric acid from 1.5 microm (SD 0.4 microm) to 2.5 microm (SD 0.9 microm) to 6.0 microm (SD 3.7 microm). At a fixed time of 30 min, attrition in saline was 5.2 microm (SD 3.6 microm) at 200 g and 8.1 microm (SD 1.5 microm) at 400 g and combined attrition/erosion in citric acid 2.8 microm (SD 1.2 microm) and 3.6 microm (SD 0.7 microm). Comparison between both environments revealed significant differences at fixed load at all time points (p < 0.01) and at fixed time between 400 and 600 g (p < 0.01). Load and time significantly influence enamel wear both in acid and neutral conditions but the effects were not linear. Copyright 2002 Elsevier Science Ltd.
Reliability of unstable periodic orbit based control strategies in biological systems.
Mishra, Nagender; Hasse, Maria; Biswal, B; Singh, Harinder P
2015-04-01
Presence of recurrent and statistically significant unstable periodic orbits (UPOs) in time series obtained from biological systems is now routinely used as evidence for low dimensional chaos. Extracting accurate dynamical information from the detected UPO trajectories is vital for successful control strategies that either aim to stabilize the system near the fixed point or steer the system away from the periodic orbits. A hybrid UPO detection method from return maps that combines topological recurrence criterion, matrix fit algorithm, and stringent criterion for fixed point location gives accurate and statistically significant UPOs even in the presence of significant noise. Geometry of the return map, frequency of UPOs visiting the same trajectory, length of the data set, strength of the noise, and degree of nonstationarity affect the efficacy of the proposed method. Results suggest that establishing determinism from unambiguous UPO detection is often possible in short data sets with significant noise, but derived dynamical properties are rarely accurate and adequate for controlling the dynamics around these UPOs. A repeat chaos control experiment on epileptic hippocampal slices through more stringent control strategy and adaptive UPO tracking is reinterpreted in this context through simulation of similar control experiments on an analogous but stochastic computer model of epileptic brain slices. Reproduction of equivalent results suggests that far more stringent criteria are needed for linking apparent success of control in such experiments with possible determinism in the underlying dynamics.
Foliar and woody materials discriminated using terrestrial LiDAR in a mixed natural forest
NASA Astrophysics Data System (ADS)
Zhu, Xi; Skidmore, Andrew K.; Darvishzadeh, Roshanak; Niemann, K. Olaf; Liu, Jing; Shi, Yifang; Wang, Tiejun
2018-02-01
Separation of foliar and woody materials using remotely sensed data is crucial for the accurate estimation of leaf area index (LAI) and woody biomass across forest stands. In this paper, we present a new method to accurately separate foliar and woody materials using terrestrial LiDAR point clouds obtained from ten test sites in a mixed forest in Bavarian Forest National Park, Germany. Firstly, we applied and compared an adaptive radius near-neighbor search algorithm with a fixed radius near-neighbor search method in order to obtain both radiometric and geometric features derived from terrestrial LiDAR point clouds. Secondly, we used a random forest machine learning algorithm to classify foliar and woody materials and examined the impact of understory and slope on the classification accuracy. An average overall accuracy of 84.4% (Kappa = 0.75) was achieved across all experimental plots. The adaptive radius near-neighbor search method outperformed the fixed radius near-neighbor search method. The classification accuracy was significantly higher when the combination of both radiometric and geometric features was utilized. The analysis showed that increasing slope and understory coverage had a significant negative effect on the overall classification accuracy. Our results suggest that the utilization of the adaptive radius near-neighbor search method coupling both radiometric and geometric features has the potential to accurately discriminate foliar and woody materials from terrestrial LiDAR data in a mixed natural forest.
Advanced controls for light sources
NASA Astrophysics Data System (ADS)
Biedron, S. G.; Edelen, A. L.; Milton, S. V.
2016-09-01
We present a summary of our team's recent efforts in developing adaptive, artificial intelligence-inspired techniques specifically to address several control challenges that arise in machines/systems including those in particle accelerator systems. These techniques can readily be adapted to other systems such as lasers, beamline optics, etc… We are not at all suggesting that we create an autonomous system, but create a system with an intelligent control system, that can continually use operational data to improve itself and combines both traditional and advanced techniques. We believe that the system performance and reliability can be increased based on our findings. Another related point is that the controls sub-system of an overall system is usually not the heart of the system architecture or design process. More bluntly, often times all of the peripheral systems are considered as secondary to the main system components in the architecture design process because it is assumed that the controls system will be able to "fix" challenges found later with the sub-systems for overall system operation. We will show that this is not always the case and that it took an intelligent control application to overcome a sub-system's challenges. We will provide a recent example of such a "fix" with a standard controller and with an artificial intelligence-inspired controller. A final related point to be covered is that of system adaptation for requirements not original to a system's original design.
Reliability of unstable periodic orbit based control strategies in biological systems
NASA Astrophysics Data System (ADS)
Mishra, Nagender; Hasse, Maria; Biswal, B.; Singh, Harinder P.
2015-04-01
Presence of recurrent and statistically significant unstable periodic orbits (UPOs) in time series obtained from biological systems is now routinely used as evidence for low dimensional chaos. Extracting accurate dynamical information from the detected UPO trajectories is vital for successful control strategies that either aim to stabilize the system near the fixed point or steer the system away from the periodic orbits. A hybrid UPO detection method from return maps that combines topological recurrence criterion, matrix fit algorithm, and stringent criterion for fixed point location gives accurate and statistically significant UPOs even in the presence of significant noise. Geometry of the return map, frequency of UPOs visiting the same trajectory, length of the data set, strength of the noise, and degree of nonstationarity affect the efficacy of the proposed method. Results suggest that establishing determinism from unambiguous UPO detection is often possible in short data sets with significant noise, but derived dynamical properties are rarely accurate and adequate for controlling the dynamics around these UPOs. A repeat chaos control experiment on epileptic hippocampal slices through more stringent control strategy and adaptive UPO tracking is reinterpreted in this context through simulation of similar control experiments on an analogous but stochastic computer model of epileptic brain slices. Reproduction of equivalent results suggests that far more stringent criteria are needed for linking apparent success of control in such experiments with possible determinism in the underlying dynamics.
Fixed-dose combination therapy for the prevention of cardiovascular disease
de Cates, Angharad N; Farr, Matthew RB; Wright, Nicola; Jarvis, Morag C; Rees, Karen; Ebrahim, Shah; Huffman, Mark D
2014-01-01
Background Cardiovascular disease (CVD) is the leading cause of death and disability worldwide, yet CVD risk factor control and secondary prevention rates remain low. A fixed-dose combination of blood pressure and cholesterol lowering and antiplatelet treatments into a single pill, or polypill, has been proposed as one strategy to reduce the global burden of CVD by up to 80% given its potential for better adherence and lower costs. Objectives To determine the effectiveness of fixed-dose combination therapy on reducing fatal and non-fatal CVD events and on improving blood pressure and lipid CVD risk factors for both primary and secondary prevention of CVD. We also aimed to determine discontinuation rates, adverse events, health-related quality of life, and costs of fixed-dose combination therapy. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) in The Cochrane Library(2013, Issue 6), MEDLINE Ovid (1946 to week 2 July 2013), EMBASE Ovid (1980 to Week 28 2013), ISI Web of Science (1970 to 19 July 2013), and the Database of Abstracts of Reviews of Effects (DARE), Health Technology Assessment Database (HTA), and Health Economics Evaluations Database (HEED) (2011, Issue 4) in The Cochrane Library. We used no language restrictions. Selection criteria We included randomised controlled trials of a fixed-dose combination therapy including at least one blood pressure lowering and one lipid lowering component versus usual care, placebo, or a single drug active component for any treatment duration in adults ≥ 18 years old with no restrictions on presence or absence of pre-existing cardiovascular disease. Data collection and analysis Three review authors independently selected studies for inclusion and extracted the data. We evaluated risk of bias using the Cochrane risk of bias assessment tool. We sought to include outcome data on all-cause mortality, fatal and non-fatal CVD events, adverse events, changes in systolic and diastolic blood pressure, total and low density lipoprotein (LDL) cholesterol concentrations, discontinuation rates, quality of life, and costs. We calculated risk ratios (RR) for dichotomous data and weighted mean differences (MD) for continuous data with 95% confidence intervals (CI) using fixed-effect models when heterogeneity was low (I2 < 50%) and random-effects models when heterogeneity was high (I2 > 50%). Main results We found nine randomised controlled trials with a total of 7047 participants. Seven of the nine trials evaluated the effects of fixed-dose combination therapy on primary CVD prevention, and the trial length ranged from six weeks to 15 months. We found a moderate to high risk of bias in the domains of selection, performance, detection, attrition, and other types of bias in five of the nine trials. Compared with the comparator groups, the effects of the fixed-dose combination treatment on mortality (1.2% versus 1.0%, RR 1.26, 95% CI 0.67 to 2.38, N = 3465) and cardiovascular events (4.0% versus 2.9%, RR 1.38, 95% CI 0.91 to 2.10, N = 2479) were uncertain (low quality evidence). The low event rates for these outcomes, limited availability of data as only two out of nine trials reported on these outcomes, and a high risk of bias in at least one domain suggest that these results should not be viewed with confidence. Adverse events were common in both the intervention (30%) and comparator (24%) groups, with participants randomised to fixed-dose combination therapy being 20% (95% CI 9% to 30%) more likely to report an adverse event. Notably, no serious adverse events were reported. Compared with placebo, the rate of discontinuation among participants randomised to fixed-dose combination was higher (14% versus 11%, RR 1.26 95% CI 1.02 to 1.55). The weighted mean differences in systolic and diastolic blood pressure between the intervention and control arms were -7.05 mmHg (95% CI -10.18 to -3.87) and -3.65 mmHg (95% CI -5.44 to -1.85), respectively. The weighted mean differences (95% CI) in total and LDL cholesterol between the intervention and control arms were -0.75 mmol/L (95% CI -1.05 to -0.46) and -0.81 mmol/L (95% CI -1.09 to -0.53), respectively. There was a high degree of statistical heterogeneity in comparisons of blood pressure and lipids (I2 ≥ 70% for all) that could not be explained, so these results should be viewed with caution. Fixed-dose combination therapy improved adherence to a multi-drug strategy by 33% (26% to 41%) compared with usual care, but this comparison was reported in only one study. The effects of fixed-dose combination therapy on quality of life are uncertain, though these results were reported in only one trial. No trials reported costs. Authors' conclusions Compared with placebo, single drug active component, or usual care, the effects of fixed-dose combination therapy on all-cause mortality or CVD events are uncertain; only few trials report these outcomes and the included trials were primarily designed to observe changes in CVD risk factor levels rather than clinical events. Reductions in blood pressure and lipid parameters are generally lower than those previously projected, though substantial heterogeneity of results exists. Fixed-dose combination therapy is associated with modest increases in adverse events compared with placebo, single drug active component, or usual care but may be associated with improved adherence to a multidrug regimen. Ongoing trials of fixed-dose combination therapy will likely inform key outcomes. PMID:24737108
Halpern, Bruno; Mancini, Marcio C
2017-01-01
Few studies on combination therapies for the treatment of obesity had been conducted until recently, when two fixed-dose combinations, bupropion-naltrexone ER fixed-dose combination and phentermine-topiramate ER titrated-dose combinations were evaluated in clinical studies that ultimately led to FDA approval. Areas covered: In this review, we discuss safety concerns about both combinations, the rationale and history of combination therapies for obesity (including phentermine plus fenfluramine), and possible future new combinations. Expert opinion: Combination therapies are a promising new area in obesity treatment, similar to what occurs with diabetes and hypertension. Safety assessment is highly important due to the high number of potential users on a chronic basis.
Transfers between libration-point orbits in the elliptic restricted problem
NASA Astrophysics Data System (ADS)
Hiday, L. A.; Howell, K. C.
The present time-fixed impulsive transfers between 3D libration point orbits in the vicinity of the interior L(1) libration point of the sun-earth-moon barycenter system are 'optimal' in that the total characteristic velocity required for implementation of the transfer exhibits a local minimum. The conditions necessary for a time-fixed, two-impulse transfer trajectory to be optimal are stated in terms of the primer vector, and the conditions necessary for satisfying the local optimality of a transfer trajectory containing additional impulses are addressed by requiring continuity of the Hamiltonian and the derivative of the primer vector at all interior impulses.
Gobbi, Riccardo Gomes; Pereira, César Augusto Martins; Sadigursky, David; Demange, Marco Kawamura; Tírico, Luis Eduardo Passarelli; Pécora, José Ricardo; Camanho, Gilberto Luis
2016-10-01
The location of patellar and femoral fixation of the graft in medial patellofemoral ligament reconstructions has been widely discussed. This study aimed to assess the distances between different patellar and femoral fixation points to identify the least anisometric pairs of points. Ten cadaver knees were attached to an apparatus that simulated an active range of motion of 120°, with three metallic markers fixed onto the medial side of the patella, and seven markings onto the medial epicondyle. The examined points included the proximal patella pole (1), the patellar center (3), the midpoint between points 1 and 3 (2), a point directly on the epicondyle (6), points 5mm anterior (5) and posterior (7) to the epicondyle, points 5mm anterior to point 5 (4) and 5mm posterior to point 7 (8), and points 5mm proximal (9) and distal (10) to the epicondyle. The distances between patella and femur points were measured by a photogrammetry system at 15° intervals. The pair of points that exhibited the lowest average variability in distance, and hence was the most isometric, was the patella center combined with the anterior to the medial femoral epicondyle. The pairs of points that exhibited the highest average variability in distance, and hence were the least isometric, were the ones located distal or posterior to the medial femoral epicondyle, with less influence by the patellar location. Surgeons should avoid positioning the graft distally or posterior to the epicondyle due to the increase in anisometry. Copyright © 2016 Elsevier Ltd. All rights reserved.
Point pattern analysis of FIA data
Chris Woodall
2002-01-01
Point pattern analysis is a branch of spatial statistics that quantifies the spatial distribution of points in two-dimensional space. Point pattern analysis was conducted on stand stem-maps from FIA fixed-radius plots to explore point pattern analysis techniques and to determine the ability of pattern descriptions to describe stand attributes. Results indicate that the...
Maxwell's conjecture on three point charges with equal magnitudes
NASA Astrophysics Data System (ADS)
Tsai, Ya-Lun
2015-08-01
Maxwell's conjecture on three point charges states that the number of non-degenerate equilibrium points of the electrostatic field generated by them in R3 is at most four. We prove the conjecture in the cases when three point charges have equal magnitudes and show the number of isolated equilibrium points can only be zero, two, three, or four. Specifically, fixing positions of two positive charges in R3, we know exactly where to place the third positive charge to have two, three, or four equilibrium points. All equilibrium points are isolated and there are no other possibilities for the number of isolated equilibrium points. On the other hand, if both two of the fixed charges have negative charge values, there are always two equilibrium points except when the third positive charge lies in the line segment connecting the two negative charges. The exception cases are when the field contains only a curve of equilibrium points. In this paper, computations assisted by computer involve symbolic and exact integer computations. Therefore, all the results are proved rigorously.
Code of Federal Regulations, 2014 CFR
2014-10-01
.... A regularly interacting group of base, mobile and associated control and fixed relay stations... qualify as unrestricted. Control point. Any place from which a transmitter's functions may be controlled. Control station. An Operational Fixed Station, the transmissions of which are used to control...
Code of Federal Regulations, 2013 CFR
2013-10-01
.... A regularly interacting group of base, mobile and associated control and fixed relay stations... qualify as unrestricted. Control point. Any place from which a transmitter's functions may be controlled. Control station. An Operational Fixed Station, the transmissions of which are used to control...
Luszczki, Jarogniew J; Ratnaraj, Neville; Patsalos, Philip N; Czuczwar, Stanislaw J
2006-11-01
Isobolographic analysis was used to characterize the interactions between stiripentol (STP) and clonazepam (CZP), ethosuximide (ETS), phenobarbital (PB), and valproate (VPA) in suppressing pentylenetetrazole (PTZ)-induced clonic seizures in mice. The anticonvulsant and acute adverse (neurotoxic) effects of STP in combination with the various conventional antiepileptic drugs (AEDs), at fixed ratios of 1:3, 1:1, and 3:1, were evaluated in the PTZ and chimney tests in mice using the isobolographic analysis. Additionally, protective indices (PI) and benefit indices (BI) were calculated to identify their pharmacological profiles so that a ranking in relation to advantageous combination could be established. Moreover, adverse-effect paradigms were determined by use of the step-through passive avoidance task (long-term memory), threshold for the first pain reaction, grip-strength test (neuromuscular tone), and the hot plate test (acute thermal pain). Brain AED concentrations were also measured so as to ascertain any pharmacokinetic contribution to the pharmacodynamic interactions. All AED combinations comprising of STP and CZP, ETS, PB, and VPA (at the fixed ratios of 1:3, 1:1 and 3:1) were additive in terms of clonic seizure suppression in the PTZ test. However, these interactions were complicated by changes in brain AED concentrations consequent to pharmacokinetic interactions. Thus STP significantly increased total brain ETS and PB concentrations, and decreased VPA concentrations, but was without effect on CZP concentrations. In contrast, PB significantly decreased and VPA increased total brain STP concentrations while CZP and ETS were without effect. Furthermore, while isobolographic analysis revealed that STP and CZP in combination, at the fixed ratios of 1:1 and 3:1, were supraadditive (synergistic; p < 0.05), the combinations of STP with CZP (1:3), ETS, PB, or VPA (at all fixed ratios of 1:3, 1:1, and 3:1) were barely additivity in terms of acute neurotoxic adverse effects in the chimney test. Additionally, none of the examined combinations of STP with conventional AEDs (CZP, ETS, PB, VPA--at their median effective doses from the PTZ-test) affected long-term memory, threshold for the first pain reaction, neuromuscular tone, and acute thermal pain. Based on BI values, the combination of STP with PB at the fixed ratio of 1:3 appears to be a particularly favourable combination. In contrast, STP and CZP or ETS (at the fixed ratios of 1:1 and 3:1) were unfavorable combinations. However, these conclusions are confounded by the fact that STP is associated with significant pharmacokinetic interactions. The remaining combinations of STP with PB (1:1 and 3:1), CZP (1:3), ETS (1:3), and VPA (at all fixed ratios of 1:3, 1:1, and 3:1) do not appear to be potential favorable AED combinations.
2011-01-01
reliability, e.g., Turbo Codes [2] and Low Density Parity Check ( LDPC ) codes [3]. The challenge to apply both MIMO and ECC into wireless systems is on...REPORT Fixed-point Design of theLattice-reduction-aided Iterative Detection andDecoding Receiver for Coded MIMO Systems 14. ABSTRACT 16. SECURITY...illustrates the performance of coded LR aided detectors. 1. REPORT DATE (DD-MM-YYYY) 4. TITLE AND SUBTITLE 13. SUPPLEMENTARY NOTES The views, opinions
Hypercuboidal renormalization in spin foam quantum gravity
NASA Astrophysics Data System (ADS)
Bahr, Benjamin; Steinhaus, Sebastian
2017-06-01
In this article, we apply background-independent renormalization group methods to spin foam quantum gravity. It is aimed at extending and elucidating the analysis of a companion paper, in which the existence of a fixed point in the truncated renormalization group flow for the model was reported. Here, we repeat the analysis with various modifications and find that both qualitative and quantitative features of the fixed point are robust in this setting. We also go into details about the various approximation schemes employed in the analysis.
Helicopter simulation: An aircrew training and qualification perspective
NASA Technical Reports Server (NTRS)
Birnbach, Richard A.; Longridge, Thomas M.
1992-01-01
This paper reviews some of the unique considerations that distinguish the commercial rotary wing domain from its fixed-wing counterpart. These considerations should give the FAA cause to proceed cautiously in drawing upon its fixed-wing experience. One major point to consider is the following: device qualification should be accomplished in a context of an overall training and qualification system. This approach would take as its starting point a detailed analysis of rotary-wing missions and tasks from which proficiency objectives can be systematically developed.
NASA Astrophysics Data System (ADS)
Katzav, Eytan
2013-04-01
In this paper, a mode of using the Dynamic Renormalization Group (DRG) method is suggested in order to cope with inconsistent results obtained when applying it to a continuous family of one-dimensional nonlocal models. The key observation is that the correct fixed-point dynamical system has to be identified during the analysis in order to account for all the relevant terms that are generated under renormalization. This is well established for static problems, however poorly implemented in dynamical ones. An application of this approach to a nonlocal extension of the Kardar-Parisi-Zhang equation resolves certain problems in one-dimension. Namely, obviously problematic predictions are eliminated and the existing exact analytic results are recovered.
Subjective study of preferred listening conditions in Italian Catholic churches
NASA Astrophysics Data System (ADS)
Martellotta, Francesco
2008-10-01
The paper describes the results of research aimed at investigating the preferred subjective listening conditions inside churches. The effect of different musical motifs (spanning Gregorian chants to symphonic music) was investigated and regression analysis was performed in order to point out the relationship between subjective ratings and acoustical parameters. In order to present realistic listening conditions to the subjects a small subset of nine churches was selected among a larger set of acoustic data collected in several Italian churches during a widespread on-site survey. The subset represented different architectural styles and shapes, and was characterized by average listening conditions. For each church a single source-receiver combination with fixed relative positions was chosen. Measured binaural impulse responses were cross-talk cancelled and then convolved with five anechoic motifs. Paired comparisons were finally performed, asking a trained panel of subjects their preference. Factor analysis pointed out a substantially common underlying pattern characterizing subjective responses. The results show that preferred listening conditions vary as a function of the musical motif, depending on early decay time for choral music and on a combination of initial time delay and lateral energy for instrumental music.
Combination probes for stagnation pressure and temperature measurements in gas turbine engines
NASA Astrophysics Data System (ADS)
Bonham, C.; Thorpe, S. J.; Erlund, M. N.; Stevenson, R. J.
2018-01-01
During gas turbine engine testing, steady-state gas-path stagnation pressures and temperatures are measured in order to calculate the efficiencies of the main components of turbomachinery. These measurements are acquired using fixed intrusive probes, which are installed at the inlet and outlet of each component at discrete point locations across the gas-path. The overall uncertainty in calculated component efficiency is sensitive to the accuracy of discrete point pressures and temperatures, as well as the spatial sampling across the gas-path. Both of these aspects of the measurement system must be considered if more accurate component efficiencies are to be determined. High accuracy has become increasingly important as engine manufacturers have begun to pursue small gains in component performance, which require efficiencies to be resolved to within less than ± 1% . This article reports on three new probe designs that have been developed in a response to this demand. The probes adopt a compact combination arrangement that facilitates up to twice the spatial coverage compared to individual stagnation pressure and temperature probes. The probes also utilise novel temperature sensors and high recovery factor shield designs that facilitate improvements in point measurement accuracy compared to standard Kiel probes used in engine testing. These changes allow efficiencies to be resolved within ± 1% over a wider range of conditions than is currently achievable with Kiel probes.
Hu, Dayi; Sun, Yihong; Liao, Yuhua; Huang, Jing; Zhao, Ruiping; Yang, Kan
2016-01-01
To assess the blood pressure-lowering efficacy and tolerability of perindopril/amlodipine fixed-dose combinations in Chinese patients with mild-to-moderate essential hypertension not adequately controlled with monotherapy alone. In 2 separate double-blind studies, patients received a 4-week run-in monotherapy of amlodipine 5 mg or perindopril 4 mg, respectively. Those whose blood pressure was uncontrolled were then randomized to receive the fixed-dose combination of perindopril 5 mg/amlodipine 5 mg (Per/Amlo group) or remain on the monotherapy for 8 weeks. Patients who were uncontrolled at the week 8 (W8) visit were up-titrated for the Per/Amlo combination, or received additional treatment if on monotherapy, for a further 4 weeks. The main efficacy assessment was at 8 weeks. After 8 weeks, systolic blood pressure (SBP; primary criterion) was statistically significantly lower in the Per/Amlo group (vs. Amlo 5 mg, p = 0.0095; vs. Per 4 mg, p < 0.0001). Uncontrolled patients at W8 who received an up-titration of the Per/Amlo combination showed a further SBP reduction. These changes were mirrored by reassuring reductions in diastolic blood pressure. The fixed-dose combinations were well tolerated. Single-pill combinations of perindopril and amlodipine provide hypertensive patients with a convenient and effective method of reducing blood pressure. © 2016 S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Pakpahan, Eka K. A.; Iskandar, Bermawi P.
2015-12-01
Mining industry is characterized by a high operational revenue, and hence high availability of heavy equipment used in mining industry is a critical factor to ensure the revenue target. To maintain high avaliability of the heavy equipment, the equipment's owner hires an agent to perform maintenance action. Contract is then used to control the relationship between the two parties involved. The traditional contracts such as fixed price, cost plus or penalty based contract studied is unable to push agent's performance to exceed target, and this in turn would lead to a sub-optimal result (revenue). This research deals with designing maintenance contract compensation schemes. The scheme should induce agent to select the highest possible maintenance effort level, thereby pushing agent's performance and achieve maximum utility for both parties involved. Principal agent theory is used as a modeling approach due to its ability to simultaneously modeled owner and agent decision making process. Compensation schemes considered in this research includes fixed price, cost sharing and revenue sharing. The optimal decision is obtained using a numerical method. The results show that if both parties are risk neutral, then there are infinite combination of fixed price, cost sharing and revenue sharing produced the same optimal solution. The combination of fixed price and cost sharing contract results in the optimal solution when the agent is risk averse, while the optimal combination of fixed price and revenue sharing contract is obtained when agent is risk averse. When both parties are risk averse, the optimal compensation scheme is a combination of fixed price, cost sharing and revenue sharing.
APMP.T-K3.4: key comparison of realizations of the ITS-90 over the range -38.8344 °C to 419.527 °C
NASA Astrophysics Data System (ADS)
Joung, W.; Gam, K. S.; Achmadi, A.; Trisna, B. A.
2016-01-01
The APMP bilateral key comparison APMP.T-K3.4 was initiated on the request from RCM-LIPI (Indonesia) to link their national standards to the average reference values (ARVs) of the CCT-K3. Korea Research Institute of Standards and Science (KRISS, Republic of Korea) provided the linkage to the CCT-K3 for temperatures ranging from -38.8344 °C to 419.527 °C. In the APMP.T-K3.4, two standard platinum resistance thermometers (SPRTs) were chosen as the transfer instruments and were calibrated at the ITS-90 fixed-points in the comparison range. The fixed-points in this comparison included Zn freezing point (419.527 °C), Sn freezing point (231.928 °C), In freezing point (156.5985 °C), Ga melting point (29.7646 °C), and Hg triple point (-38.8344 °C). The comparison was carried out in a participant-pilot-participant sequence where KRISS served as the pilot. The linkage was based on the fixed-point resistance ratios of RCM-LIPI relative to the ARVs of the CCT-K3 via the difference between the fixed-point resistance ratios of KRISS and the ARVs of the CCT-K3. The temperature differences between the national standards of RCM-LIPI and the ARVs of the CCT-K3 were within the evaluated comparison uncertainties of the ATPM.T-K3.4. This report provides detailed information on the comparison results, linkage mechanism, and the Degree of Equivalence of the RCM-LIPI relative to the institutes having participated in the CCT-K3. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Bouloc, A; Roo, E; Imko-Walczuk, B; Moga, A; Chadoutaud, B; Dréno, B
2017-10-01
Acne in adult women is an increasing reason for dermatological consultations. The aim of this study was to assess in adult women with mild acne the efficacy and tolerance of a daily adjunctive application of a skincare (Normaderm ® , Laboratoires Vichy, France) to a fixed combination of adapalene/benzoyl peroxide daily or every other evening and a standard emollient. Subjects were randomized to receive the fixed combination applied either every evening or every other evening and a daily application of the standard emollient and the test care or a once daily application of the fixed combination and the standard emollient alone. Clinical evaluations at Day 0, Day 45 and Day 90 included the count of acne lesions, assessment of clinical improvement and local tolerance. The quantitative lipid profile of the stratum corneum of the forehead was also determined. After 90 days of application, acne had improved in all 299 subjects with a statistically significant difference in favour of the test care regimens (P < 0.05). Moreover, skin quality, subject satisfaction, skin discomfort and sebum composition were in favour of these regimens. In conclusion, the tested skincare combined with a fixed adapalene and benzoyl peroxide combination provides a significant adjunctive efficacy and local tolerance benefit in adult women with mild acne. © 2017 The Authors. Journal of the European Academy of Dermatology and Venereology published by John Wiley & Sons Ltd on behalf of European Academy of Dermatology and Venereology.
Lima, Karina Jerônimo Rodrigues Santiago de; Henriques, José Fernando Castanha; Janson, Guilherme; Pereira, Suelen Cristina da Costa; Neves, Leniana Santos; Cançado, Rodrigo Hermont
2013-05-01
The aim of this study was to compare the dentoskeletal changes of patients with Class II Division 1 malocclusion treated with either the Jasper jumper appliance or the activator-headgear combination, both associated with fixed appliances. The sample comprised 72 subjects with Class II Division 1 malocclusion divided into 3 groups: group 1 included 25 subjects treated with fixed appliances and the force modules of the Jasper jumper at an initial mean age of 12.72 years, group 2 included 25 subjects treated with the activator-headgear combination followed by fixed appliances at an initial mean age of 11.07 years, and group 3 included 22 untreated subjects at an initial mean age of 12.67 years. Initial cephalometric characteristics and dentoskeletal changes were compared with analysis of variance. Both experimental groups had similar dentoskeletal changes: restrictive effect on the maxilla, clockwise mandibular rotation and a slight increase in anterior face height, retrusion of the maxillary incisors, distalization of the maxillary molars, protrusion of the mandibular incisors, extrusion of the mandibular molars, and significant improvements of the maxillomandibular relationship, overjet, overbite, and the molar relationship. The effects of the Jasper jumper and the activator-headgear combination followed by fixed orthodontic appliances were similar in Class II malocclusion treatment. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
FixO3 : Early progress towards Open Ocean observatory Data Management Harmonisation
NASA Astrophysics Data System (ADS)
Pagnani, Maureen; Huber, Robert; Lampitt, Richard
2014-05-01
Since 2002 there has been a sustained effort, supported as European framework projects, to harmonise both the technology and the data management of Open Ocean fixed observatories run by European nations. FixO3 started in September 2013, and for 4 years will coordinate the convergence of data management best practice across a constellation of moorings in the Atlantic, in both hemispheres, and in the Mediterranean. To ensure the continued existence of these unique sources of oceanographic data as sustained observatories it is vital to improve access to the data collected, both in terms of methods of presentation, real-time availability, long-term archiving and quality assurance. The data management component of FixO3 will improve access to marine observatory data by harmonizing data management standards and workflows covering the complete life cycle of data from real time data acquisition to long-term archiving. Legal and data policy aspects will be examined to identify transnational barriers to open-access to marine observatory data. A harmonised FixO3 data policy is being synthesised from the partner's existing policies, which will overcome the identified barriers, and provide a formal basis for data exchange between FixO3 infrastructures. Presently, the interpretation and implementation of accepted standards has considerable incompatibilities within the observatory community, and these different approaches will be unified into the FixO3 approach. Further, FixO3 aims to harmonise data management and standardisation efforts with other European and international marine data and observatory infrastructures. The FixO3 synthesis will build on the standards established in other European infrastructures such as EDMONET, SEADATANET, PANGAEA, EuroSITES (European contribution to JCOMMP OceanSITES programme), and MyOcean (the Marine Core Service for GMES) infrastructures as well as relevant international infrastructures and data centres such as the ICOS Ocean Thematic Centre. The data management efforts are central to FixO3. Combined with the procedural and technological harmonisation, tackled in separate work packages, the FixO3 network of observatories will efficiently and cost effectively provide a consistent resource of quality controlled accessible oceanographic data The project website www.fixo3.eu is being developed as both a data showcase and single distribution point, and with database driven tools will enable the sharing of information between the observatories in the most smart and cost effective way. The network of knowledge built throughout the project will become a legacy resource that will ensure access to the unique ensemble data sets only achievable at these key observatories.
Dynamics of Two Point Vortices in an External Compressible Shear Flow
NASA Astrophysics Data System (ADS)
Vetchanin, Evgeny V.; Mamaev, Ivan S.
2017-12-01
This paper is concerned with a system of equations that describes the motion of two point vortices in a flow possessing constant uniform vorticity and perturbed by an acoustic wave. The system is shown to have both regular and chaotic regimes of motion. In addition, simple and chaotic attractors are found in the system. Attention is given to bifurcations of fixed points of a Poincaré map which lead to the appearance of these regimes. It is shown that, in the case where the total vortex strength changes, the "reversible pitch-fork" bifurcation is a typical scenario of emergence of asymptotically stable fixed and periodic points. As a result of this bifurcation, a saddle point, a stable and an unstable point of the same period emerge from an elliptic point of some period. By constructing and analyzing charts of dynamical regimes and bifurcation diagrams we show that a cascade of period-doubling bifurcations is a typical scenario of transition to chaos in the system under consideration.
Bernstein, Andrey; Wang, Cong; Dall'Anese, Emiliano; ...
2018-01-01
This paper considers unbalanced multiphase distribution systems with generic topology and different load models, and extends the Z-bus iterative load-flow algorithm based on a fixed-point interpretation of the AC load-flow equations. Explicit conditions for existence and uniqueness of load-flow solutions are presented. These conditions also guarantee convergence of the load-flow algorithm to the unique solution. The proposed methodology is applicable to generic systems featuring (i) wye connections; (ii) ungrounded delta connections; (iii) a combination of wye-connected and delta-connected sources/loads; and, (iv) a combination of line-to-line and line-to-grounded-neutral devices at the secondary of distribution transformers. Further, a sufficient condition for themore » non-singularity of the load-flow Jacobian is proposed. Finally, linear load-flow models are derived, and their approximation accuracy is analyzed. Theoretical results are corroborated through experiments on IEEE test feeders.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bernstein, Andrey; Wang, Cong; Dall'Anese, Emiliano
This paper considers unbalanced multiphase distribution systems with generic topology and different load models, and extends the Z-bus iterative load-flow algorithm based on a fixed-point interpretation of the AC load-flow equations. Explicit conditions for existence and uniqueness of load-flow solutions are presented. These conditions also guarantee convergence of the load-flow algorithm to the unique solution. The proposed methodology is applicable to generic systems featuring (i) wye connections; (ii) ungrounded delta connections; (iii) a combination of wye-connected and delta-connected sources/loads; and, (iv) a combination of line-to-line and line-to-grounded-neutral devices at the secondary of distribution transformers. Further, a sufficient condition for themore » non-singularity of the load-flow Jacobian is proposed. Finally, linear load-flow models are derived, and their approximation accuracy is analyzed. Theoretical results are corroborated through experiments on IEEE test feeders.« less
Dynamics and Physiological Roles of Stochastic Firing Patterns Near Bifurcation Points
NASA Astrophysics Data System (ADS)
Jia, Bing; Gu, Huaguang
2017-06-01
Different stochastic neural firing patterns or rhythms that appeared near polarization or depolarization resting states were observed in biological experiments on three nervous systems, and closely matched those simulated near bifurcation points between stable equilibrium point and limit cycle in a theoretical model with noise. The distinct dynamics of spike trains and interspike interval histogram (ISIH) of these stochastic rhythms were identified and found to build a relationship to the coexisting behaviors or fixed firing frequency of four different types of bifurcations. Furthermore, noise evokes coherence resonances near bifurcation points and plays important roles in enhancing information. The stochastic rhythms corresponding to Hopf bifurcation points with fixed firing frequency exhibited stronger coherence degree and a sharper peak in the power spectrum of the spike trains than those corresponding to saddle-node bifurcation points without fixed firing frequency. Moreover, the stochastic firing patterns changed to a depolarization resting state as the extracellular potassium concentration increased for the injured nerve fiber related to pathological pain or static blood pressure level increased for aortic depressor nerve fiber, and firing frequency decreased, which were different from the physiological viewpoint that firing frequency increased with increasing pressure level or potassium concentration. This shows that rhythms or firing patterns can reflect pressure or ion concentration information related to pathological pain information. Our results present the dynamics of stochastic firing patterns near bifurcation points, which are helpful for the identification of both dynamics and physiological roles of complex neural firing patterns or rhythms, and the roles of noise.
The colorimetric analysis of anti-tuberculosis fixed-dose combination tablets and capsules.
Ellard, G A
1999-11-01
The perceived need to demonstrate whether or not the actual amounts of rifampicin, isoniazid and pyrazinamide in fixed-dose combination tablets or capsules correspond to their stated drug contents. To adapt specific, robust and simple colorimetric methods that have been previously applied to measuring plasma and urinary rifampicin, isoniazid, pyrazinamide and ethambutol concentrations to estimate tablet and capsule drug contents. The methods were applied to the analysis of 14 commercially manufactured fixed-dose combinations: two capsule and three tablet formulations containing rifampicin and isoniazid; seven tablet formulations containing rifampicin, isoniazid and pyrazinamide; and two tablet formulations containing rifampicin, isoniazid, pyrazinamide and ethambutol. All the combined formulations contained near to their stated drug contents. Replicate analyses confirmed the excellent precision of the drug analyses. Such methods are not only rapid to perform but should be practical in many Third World situations with relatively modest laboratory facilities.
Code of Federal Regulations, 2011 CFR
2011-10-01
... interacting group of base, mobile and associated control and fixed relay stations intended to provide land... one that does not qualify as unrestricted. Control point. Any place from which a transmitter's functions may be controlled. Control station. An Operational Fixed Station, the transmissions of which are...
Code of Federal Regulations, 2010 CFR
2010-10-01
... interacting group of base, mobile and associated control and fixed relay stations intended to provide land... one that does not qualify as unrestricted. Control point. Any place from which a transmitter's functions may be controlled. Control station. An Operational Fixed Station, the transmissions of which are...
Code of Federal Regulations, 2012 CFR
2012-10-01
... interacting group of base, mobile and associated control and fixed relay stations intended to provide land... one that does not qualify as unrestricted. Control point. Any place from which a transmitter's functions may be controlled. Control station. An Operational Fixed Station, the transmissions of which are...
Limited sampling strategies to predict the area under the concentration-time curve for rifampicin.
Medellín-Garibay, Susanna E; Correa-López, Tania; Romero-Méndez, Carmen; Milán-Segovia, Rosa C; Romano-Moreno, Silvia
2014-12-01
Rifampicin (RMP) is the most effective first-line antituberculosis drug. One of the most critical aspects of using it in fixed-drug combination formulations is to ensure it reaches therapeutic levels in blood. The determination of the area under the concentration-time curve (AUC) and appropriate dose adjustment of this drug may contribute to optimization of therapy. Even when the maximal concentration (Cmax) of RMP also predicts its sterilizing effect, the time to reach it (Tmax) takes 40 minutes to 6 hours. The aim of this study was to develop a limited sampling strategy (LSS) for therapeutic drug monitoring assistance for RMP. Full concentration-time curves were obtained from 58 patients with tuberculosis (TB) after the oral administration of RMP in fixed-drug combination formulation. A validated high-performance liquid chromatographic method was used. Pharmacokinetic parameters were estimated with a noncompartmental model. Generalized linear models were obtained by forward steps, and bootstrapping was performed to develop LSS to predict AUC curve from time 0 to the last measured at 24 hours postdose (AUC0-24). The predictive performance of the proposed models was assessed using RMP profiles from 25 other TB patients by comparing predicted and observed AUC0-24. The mean AUC0-24 in the current study was 91.46 ± 36.7 mg·h·L, and the most convenient sampling time points to predict it were 2, 4 and 12 hours postdose (slope [m] = 0.955 ± 0.06; r = 0.92). The mean prediction error was -0.355%, and the root mean square error was 5.6% in the validation group. Alternate LSSs are proposed with 2 of these sampling time points, which also provide good predictions when the 3 most convenient are not feasible. The AUC0-24 for RMP in TB patients can be predicted with acceptable precision through a 2- or 3-point sampling strategy, despite wide interindividual variability. These LSSs could be applied in clinical practice to optimize anti-TB therapy based on therapeutic drug monitoring.
Ultra-high temperature isothermal furnace liners (IFLS) for copper freeze point cells
NASA Astrophysics Data System (ADS)
Dussinger, P. M.; Tavener, J. P.
2013-09-01
Primary Laboratories use large fixed-point cells in deep calibration furnaces utilizing heat pipes to achieve temperature uniformity. This combination of furnace, heat pipe, and cell gives the smallest of uncertainties. The heat pipe, also known as an isothermal furnace liner (IFL), has typically been manufactured with Alloy 600/601 as the envelope material since the introduction of high temperature IFLs over 40 years ago. Alloy 600/601 is a widely available high temperature material, which is compatible with Cesium, Potassium, and Sodium and has adequate oxidation resistance and reasonable high temperature strength. Advanced Cooling Technologies, Inc. (ACT) Alloy 600/Sodium IFLs are rated to 1100°C for approximately 1000 hours of operation (based on creep strength). Laboratories interested in performing calibrations and studies around the copper freezing point (1084.62°C) were frustrated by the 1000 hours at 1100°C limitation and the fact that expensive freeze-point cells were getting stuck and/or crushed inside the IFL. Because of this growing frustration/need, ACT developed an Ultra High Temperature IFL to take advantage of the exceptional high temperature strength properties of Haynes 230.
Quantum gravity fluctuations flatten the Planck-scale Higgs potential
NASA Astrophysics Data System (ADS)
Eichhorn, Astrid; Hamada, Yuta; Lumma, Johannes; Yamada, Masatoshi
2018-04-01
We investigate asymptotic safety of a toy model of a singlet-scalar extension of the Higgs sector including two real scalar fields under the impact of quantum-gravity fluctuations. Employing functional renormalization group techniques, we search for fixed points of the system which provide a tentative ultraviolet completion of the system. We find that in a particular regime of the gravitational parameter space the canonically marginal and relevant couplings in the scalar sector—including the mass parameters—become irrelevant at the ultraviolet fixed point. The infrared potential for the two scalars that can be reached from that fixed point is fully predicted and features no free parameters. In the remainder of the gravitational parameter space, the values of the quartic couplings in our model are predicted. In light of these results, we discuss whether the singlet-scalar could be a dark-matter candidate. Furthermore, we highlight how "classical scale invariance" in the sense of a flat potential of the scalar sector at the Planck scale could arise as a consequence of asymptotic safety.
Impact of topology in foliated quantum Einstein gravity.
Houthoff, W B; Kurov, A; Saueressig, F
2017-01-01
We use a functional renormalization group equation tailored to the Arnowitt-Deser-Misner formulation of gravity to study the scale dependence of Newton's coupling and the cosmological constant on a background spacetime with topology [Formula: see text]. The resulting beta functions possess a non-trivial renormalization group fixed point, which may provide the high-energy completion of the theory through the asymptotic safety mechanism. The fixed point is robust with respect to changing the parametrization of the metric fluctuations and regulator scheme. The phase diagrams show that this fixed point is connected to a classical regime through a crossover. In addition the flow may exhibit a regime of "gravitational instability", modifying the theory in the deep infrared. Our work complements earlier studies of the gravitational renormalization group flow on a background topology [Formula: see text] (Biemans et al. Phys Rev D 95:086013, 2017, Biemans et al. arXiv:1702.06539, 2017) and establishes that the flow is essentially independent of the background topology.
Renormalization-group theory for finite-size scaling in extreme statistics
NASA Astrophysics Data System (ADS)
Györgyi, G.; Moloney, N. R.; Ozogány, K.; Rácz, Z.; Droz, M.
2010-04-01
We present a renormalization-group (RG) approach to explain universal features of extreme statistics applied here to independent identically distributed variables. The outlines of the theory have been described in a previous paper, the main result being that finite-size shape corrections to the limit distribution can be obtained from a linearization of the RG transformation near a fixed point, leading to the computation of stable perturbations as eigenfunctions. Here we show details of the RG theory which exhibit remarkable similarities to the RG known in statistical physics. Besides the fixed points explaining universality, and the least stable eigendirections accounting for convergence rates and shape corrections, the similarities include marginally stable perturbations which turn out to be generic for the Fisher-Tippett-Gumbel class. Distribution functions containing unstable perturbations are also considered. We find that, after a transitory divergence, they return to the universal fixed line at the same or at a different point depending on the type of perturbation.
NASA Astrophysics Data System (ADS)
Bhattacharya, Somnath; Mukherjee, Pradip; Roy, Amit Singha; Saha, Anirban
2018-03-01
We consider a scalar field which is generally non-minimally coupled to gravity and has a characteristic cubic Galilean-like term and a generic self-interaction, as a candidate of a Dark Energy model. The system is dynamically analyzed and novel fixed points with perturbative stability are demonstrated. Evolution of the system is numerically studied near a novel fixed point which owes its existence to the Galileon character of the model. It turns out that demanding the stability of this novel fixed point puts a strong restriction on the allowed non-minimal coupling and the choice of the self-interaction. The evolution of the equation of state parameter is studied, which shows that our model predicts an accelerated universe throughout and the phantom limit is only approached closely but never crossed. Our result thus extends the findings of Coley, Dynamical systems and cosmology. Kluwer Academic Publishers, Boston (2013) for more general NMC than linear and quadratic couplings.
A Model of Continental Growth and Mantle Degassing Comparing Biotic and Abiotic Worlds
NASA Astrophysics Data System (ADS)
Höning, D.; Hansen-Goos, H.; Spohn, T.
2012-12-01
While examples for interaction of the biosphere with the atmosphere can be easily cited (e.g., production and consumption of O2), interaction between the biosphere and the solid planet and its interior is much less established. It has been argued (e.g., Rosing et al. 2006; Sleep et al, 2012) that the formation of continents could be a consequence of bioactivity harvesting solar energy through photosynthesis to help build the continents and that the mantle should carry a chemical biosignature. We present an interaction model that includes mantle convection, mantle water vapor degassing at mid-oceanic ridges and regassing through subduction zones, continental crust formation and erosion and water storage and transport in a porous oceanic crust that includes hydrous mineral phases. The mantle viscosity in this model depends on the water concentration in the mantle. We use boundary layer theory of mantle convection to parameterize the mantle convection flow rate and assume that the plate speed equals the mantle flow rate. The biosphere enters the calculation through the assumption that the continental erosion rate is enhanced by a factor of several through bioactivity and through an assumed reduction of the kinetic barrier to diagenetic and metamorphic reactions (e.g., Kim et al. 2004) in the sedimentary basins in subduction zones that would lead to increased water storage capacities. We further include a stochastic model of continent-to-continent interactions that limits the effective total length of subduction zones. We use present day parameters of the Earth and explore a phase plane spanned by the percentage of surface coverage of the Earth by continents and the total water content of the mantle. We vary the ratio of the erosion rate in a postulated abiotic Earth to the present Earth, as well as the activation barrier to diagenetic and metamorphic reactions that affect the water storage capacity of the subducting crust. We find stable and unstable fixed points in the phase area where the net degassing and continental growth rates are zero. Many of the parameter combinations result in one stable fixed point with a completely dry mantle that lacks continents altogether and a second stable fixed point with a continent coverage and mantle water concentration close to that of the present Earth. In addition, there is an unstable fixed point situated between the two. In general, the abiotic world has a larger zone of attraction for the fixed point with a dry mantle and no continents than the biotic world. Thus a biotic world is found to be more likely to develop continents and a have wet mantle. Furthermore, the biotic model is generally found to have a wetter mantle than an abiotic model with the same continent coverage. Through the effect of water on the mantle rheology, the biotic world would thus tend to be tectonically more active and have a more rapid long-term carbon silicate cycle. References: J. Kim, H. Dong, J. Seabaugh, S. W. Newell, D. D. Eberl, Science 303, 830-832, 2004 N. H. Sleep, D. K. Bird, E. Pope, Annu. Rev. Earth Planet. Sci. 40, 277-300, 2012 M. T. Rosing, D. K. Bird, N. H. Sleep, W. Glassley, F. Albarede, Paleo3 232, 90-113, 2006
Patient Adherence to Olmesartan/Amlodipine Combinations: Fixed Versus Extemporaneous Combinations.
Levi, Miriam; Pasqua, Alessandro; Cricelli, Iacopo; Cricelli, Claudio; Piccinni, Carlo; Parretti, Damiano; Lapi, Francesco
2016-03-01
Lack of adherence to prescribed therapies is often a cause of suboptimal blood pressure control in patients with hypertension. To enhance patients' adherence to treatment, fixed-dose combinations of active substances with complementary mechanisms of action have been developed. An angiotensin-converting enzyme inhibitor or an angiotensin receptor blocker (ARB) is often combined with a calcium channel blocker. Olmesartan is the most used ARB in combination therapy. In Italy, in September 2011, a fixed-dose combination of olmesartan/amlodipine (olmesartan/amlodipine 20/5 mg, 40/5 mg, or 40/10 mg) was introduced to treat patients with hypertension for whom control of blood pressure is not reached with either olmesartan or amlodipine alone. Prior research on adherence to olmesartan/amlodipine combinations was carried out in local contexts (e.g., claims databases of Italian regions or local health authorities), and/or it was limited by the fact that adherence was assessed against monotherapies already known for their low compliance profile, such as diuretics. To compare adherence with olmesartan/amlodipine fixed-dose combination (FDC) and extemporaneous combination in primary care in Italy. A nationwide, population-based study was conducted by using the Health Search IMS Health Longitudinal Patient Database. Patients aged > 17 years, affected by hypertension and treated with the FDC or extemporaneous combination of olmesartan/amlodipine, were identified. Adherence to these 2 therapeutic regimens was estimated by calculating the proportion of days covered (PDC). Patients were classified into 3 levels of adherence: high (PDC ≥ 80%), intermediate (PDC = 40%-79%), or low (PDC < 40%). In the 6-month follow-up, FDC showed higher adherence compared with an extemporaneous combination (55.1% vs. 15.9%, P < 0.001). This difference was confirmed in a multivariable logistic regression model clustered on patient identifier (odds ratio = 6.65; 95% CI = 3.10-14.26; P < 0.001). The proportion of patients adherent to FDC varied from 60.4% for the 40/5 mg formulation to 47.5% for the 40/10 mg formulation. These findings suggest that higher adherence may be achieved with FDCs than with extemporaneous combinations. To improve the degree of adherence, general practitioners may consider prescribing fixed combinations of antihypertensive agents as soon as monotherapies fail to achieve the expected therapeutic objective.
Varrassi, Giustino; Hanna, Magdi; Macheras, Giorgos; Montero, Antonio; Montes Perez, Antonio; Meissner, Winfried; Perrot, Serge; Scarpignato, Carmelo
2017-06-01
Untreated and under-treated pain represent one of the most pervasive health problems, which is worsening as the population ages and accrues risk for pain. Multiple treatment options are available, most of which have one mechanism of action, and cannot be prescribed at unlimited doses due to the ceiling of efficacy and/or safety concerns. Another limitation of single-agent analgesia is that, in general, pain is due to multiple causes. Combining drugs from different classes, with different and complementary mechanism(s) of action, provides a better opportunity for effective analgesia at reduced doses of individual agents. Therefore, there is a potential reduction of adverse events, often dose-related. Analgesic combinations are recommended by several organizations and are used in clinical practice. Provided the two agents are combined in a fixed-dose ratio, the resulting medication may offer advantages over extemporaneous combinations. Dexketoprofen/tramadol (25 mg/75 mg) is a new oral fixed-dose combination offering a comprehensive multimodal approach to moderate-to-severe acute pain that encompasses central analgesic action, peripheral analgesic effect and anti-inflammatory activity, together with a good tolerability profile. The analgesic efficacy of dexketoprofen/tramadol combination is complemented by a favorable pharmacokinetic and pharmacodynamic profile, characterized by rapid onset and long duration of action. This has been well documented in both somatic- and visceral-pain human models. This review discusses the available clinical evidence and the future possible applications of dexketoprofen/tramadol fixed-dose combination that may play an important role in the management of moderate-to-severe acute pain.
Spahn, Christoph; Glaesmann, Mathilda; Gao, Yunfeng; Foo, Yong Hwee; Lampe, Marko; Kenney, Linda J; Heilemann, Mike
2017-01-01
Despite their small size and the lack of compartmentalization, bacteria exhibit a striking degree of cellular organization, both in time and space. During the last decade, a group of new microscopy techniques emerged, termed super-resolution microscopy or nanoscopy, which facilitate visualizing the organization of proteins in bacteria at the nanoscale. Single-molecule localization microscopy (SMLM) is especially well suited to reveal a wide range of new information regarding protein organization, interaction, and dynamics in single bacterial cells. Recent developments in click chemistry facilitate the visualization of bacterial chromatin with a resolution of ~20 nm, providing valuable information about the ultrastructure of bacterial nucleoids, especially at short generation times. In this chapter, we describe a simple-to-realize protocol that allows determining precise structural information of bacterial nucleoids in fixed cells, using direct stochastic optical reconstruction microscopy (dSTORM). In combination with quantitative photoactivated localization microscopy (PALM), the spatial relationship of proteins with the bacterial chromosome can be studied. The position of a protein of interest with respect to the nucleoids and the cell cylinder can be visualized by super-resolving the membrane using point accumulation for imaging in nanoscale topography (PAINT). The combination of the different SMLM techniques in a sequential workflow maximizes the information that can be extracted from single cells, while maintaining optimal imaging conditions for each technique.
NASA Astrophysics Data System (ADS)
Reckziegel, S.; Kreye, D.; Puegner, T.; Vogel, U.; Scholles, M.; Grillberger, C.; Fehse, K.
2009-02-01
In this paper we present an optoelectronic integrated circuit (OEIC) based on monolithic integration of organic lightemitting diodes (OLEDs) and CMOS technology. By the use of integrated circuits, photodetectors and highly efficient OLEDs on the same silicon chip, novel OEICs with combined sensors and actuating elements can be realized. The OLEDs are directly deposited on the CMOS top metal. The metal layer serves as OLED bottom electrode and determines the bright area. Furthermore, the area below the OLED electrodes can be used for integrated circuits. The monolithic integration of actuators, sensors and electronics on a common silicon substrate brings significant advantages in most sensory applications. The developed OEIC combines three different types of sensors: a reflective sensor, a color sensor and a particle flow sensor and is configured with an orange (597nm) emitting p-i-n OLED. We describe the architecture of such a monolithic OEIC and demonstrate a method to determine the velocity of a fluid being conveyed pneumatically in a transparent capillary. The integrated OLEDs illuminate the capillary with the flowing fluid. The fluid has a random reflection profile. Depending on the velocity and a random contrast difference, more or less light is reflected back to the substrate. The integrated photodiodes located at different fixed points detect the reflected light and using crosscorrelation, the velocity is calculated from the time in which contrast differences move over a fixed distance.
Experimental determination of material damping using vibration analyzer
NASA Technical Reports Server (NTRS)
Chowdhury, Mostafiz R.; Chowdhury, Farida
1990-01-01
Structural damping is an important dynamic characteristic of engineering materials that helps to damp vibrations by reducing their amplitudes. In this investigation, an experimental method is illustrated to determine the damping characteristics of engineering materials using a dual channel Fast Fourier Transform (FFT) analyzer. A portable Compaq III computer which houses the analyzer, is used to collect the dynamic responses of three metal rods. Time-domain information is analyzed to obtain the logarithmic decrement of their damping. The damping coefficients are then compared to determine the variation of damping from material to material. The variations of damping from one point to another of the same material, due to a fixed point excitation, and the variable damping at a fixed point due to excitation at different points, are also demonstrated.
Wu, Tao; Ren, Xuejiao; Cui, Yunwei; Cheng, Xiaodong; Peng, Shuo; Hou, Zhiyong; Han, Yongtai
2018-06-19
To compare the stability of sacroiliac joint disruption fixed with three kinds of internal fixation using both biomechanical test and finite element analysis. Five embalmed specimens of an adult were used. The symphysis pubis rupture and left sacroiliac joint disruption were created. The symphysis pubis was stabilized with a five-hole plate. The sacroiliac joint disruption was fixed with three kinds of internal fixation in a randomized design. Displacements of the whole specimen and shifts in the gap were recorded. Three-dimensional finite element models of the pelvis, the pelvis with symphysis pubis rupture and left sacroiliac joint disruption, and three kinds of internal fixation techniques were created and analyzed. Under the vertical load, the displacements and shifts in the gap of the pelvis fixed with minimally invasive adjustable plate (MIAP) combined with one iliosacral (IS) screw were the smallest, and the average displacements of the pelvis fixed with an anterior plate were the largest one. The differences among them were significant. In finite element analysis and MIAP combined with one IS screw fixation showed relatively best fixation stability and lowest risks of implant failure than two IS screws fixation and anterior plate fixation. The stability of sacroiliac joint disruption fixed with MIAP combined with one IS screw is better than that fixed with two IS screws and anterior plate under vertical load.
NASA Technical Reports Server (NTRS)
Hashmall, J.; Garrick, J.
1993-01-01
Flight Dynamics Facility (FDF) responsibilities for calibration of Upper Atmosphere Research Satellite (UARS) sensors included alignment calibration of the fixed-head star trackers (FHST's) and the fine Sun sensor (FSS), determination of misalignments and scale factors for the inertial reference units (IRU's), determination of biases for the three-axis magnetometers (TAM's) and Earth sensor assemblies (ESA's), determination of gimbal misalignments of the Solar/Stellar Pointing Platform (SSPP), and field-of-view calibration for the FSS's mounted both on the Modular Attitude Control System (MACS) and on the SSPP. The calibrations, which used a combination of new and established algorithms, gave excellent results. Alignment calibration results markedly improved the accuracy of both ground and onboard Computer (OBC) attitude determination. SSPP calibration results allowed UARS to identify stars in the period immediately after yaw maneuvers, removing the delay required for the OBC to reacquire its fine pointing attitude mode. SSPP calibration considerably improved the pointing accuracy of the attached science instrument package. This paper presents a summary of the methods used and the results of all FDF UARS sensor calibration.
Chiral Modes at Exceptional Points in Exciton-Polariton Quantum Fluids
NASA Astrophysics Data System (ADS)
Gao, T.; Li, G.; Estrecho, E.; Liew, T. C. H.; Comber-Todd, D.; Nalitov, A.; Steger, M.; West, K.; Pfeiffer, L.; Snoke, D. W.; Kavokin, A. V.; Truscott, A. G.; Ostrovskaya, E. A.
2018-02-01
We demonstrate the generation of chiral modes-vortex flows with fixed handedness in exciton-polariton quantum fluids. The chiral modes arise in the vicinity of exceptional points (non-Hermitian spectral degeneracies) in an optically induced resonator for exciton polaritons. In particular, a vortex is generated by driving two dipole modes of the non-Hermitian ring resonator into degeneracy. Transition through the exceptional point in the space of the system's parameters is enabled by precise manipulation of real and imaginary parts of the closed-wall potential forming the resonator. As the system is driven to the vicinity of the exceptional point, we observe the formation of a vortex state with a fixed orbital angular momentum (topological charge). This method can be extended to generate higher-order orbital angular momentum states through coalescence of multiple non-Hermitian spectral degeneracies. Our Letter demonstrates the possibility of exploiting nontrivial and counterintuitive properties of waves near exceptional points in macroscopic quantum systems.
47 CFR 101.1005 - Frequencies available.
Code of Federal Regulations, 2011 CFR
2011-10-01
... FIXED MICROWAVE SERVICES Local Multipoint Distribution Service § 101.1005 Frequencies available. (a) The... is shared with private microwave point-to-point systems licensed prior to March 11, 1997, as provided...
47 CFR 101.1005 - Frequencies available.
Code of Federal Regulations, 2014 CFR
2014-10-01
... FIXED MICROWAVE SERVICES Local Multipoint Distribution Service § 101.1005 Frequencies available. (a) The... is shared with private microwave point-to-point systems licensed prior to March 11, 1997, as provided...
47 CFR 101.1005 - Frequencies available.
Code of Federal Regulations, 2010 CFR
2010-10-01
... FIXED MICROWAVE SERVICES Local Multipoint Distribution Service § 101.1005 Frequencies available. (a) The... is shared with private microwave point-to-point systems licensed prior to March 11, 1997, as provided...
47 CFR 101.1005 - Frequencies available.
Code of Federal Regulations, 2013 CFR
2013-10-01
... FIXED MICROWAVE SERVICES Local Multipoint Distribution Service § 101.1005 Frequencies available. (a) The... is shared with private microwave point-to-point systems licensed prior to March 11, 1997, as provided...
47 CFR 101.1005 - Frequencies available.
Code of Federal Regulations, 2012 CFR
2012-10-01
... FIXED MICROWAVE SERVICES Local Multipoint Distribution Service § 101.1005 Frequencies available. (a) The... is shared with private microwave point-to-point systems licensed prior to March 11, 1997, as provided...
47 CFR 90.419 - Points of communication.
Code of Federal Regulations, 2010 CFR
2010-10-01
... communicate between associated mobile stations and associated base stations of the licensee. Accordingly, operations between base stations at fixed locations are permitted only in the following situations: (a) Base... frequencies below 450 MHz, may communicate on a secondary basis with other base stations, operational fixed...
A Vision-Based Self-Calibration Method for Robotic Visual Inspection Systems
Yin, Shibin; Ren, Yongjie; Zhu, Jigui; Yang, Shourui; Ye, Shenghua
2013-01-01
A vision-based robot self-calibration method is proposed in this paper to evaluate the kinematic parameter errors of a robot using a visual sensor mounted on its end-effector. This approach could be performed in the industrial field without external, expensive apparatus or an elaborate setup. A robot Tool Center Point (TCP) is defined in the structural model of a line-structured laser sensor, and aligned to a reference point fixed in the robot workspace. A mathematical model is established to formulate the misalignment errors with kinematic parameter errors and TCP position errors. Based on the fixed point constraints, the kinematic parameter errors and TCP position errors are identified with an iterative algorithm. Compared to the conventional methods, this proposed method eliminates the need for a robot-based-frame and hand-to-eye calibrations, shortens the error propagation chain, and makes the calibration process more accurate and convenient. A validation experiment is performed on an ABB IRB2400 robot. An optimal configuration on the number and distribution of fixed points in the robot workspace is obtained based on the experimental results. Comparative experiments reveal that there is a significant improvement of the measuring accuracy of the robotic visual inspection system. PMID:24300597
An exploratory drilling exhaustion sequence plot program
Schuenemeyer, J.H.; Drew, L.J.
1977-01-01
The exhaustion sequence plot program computes the conditional area of influence for wells in a specified rectangular region with respect to a fixed-size deposit. The deposit is represented by an ellipse whose size is chosen by the user. The area of influence may be displayed on computer printer plots consisting of a maximum of 10,000 grid points. At each point, a symbol is presented that indicates the probability of that point being exhausted by nearby wells with respect to a fixed-size ellipse. This output gives a pictorial view of the manner in which oil fields are exhausted. In addition, the exhaustion data may be used to estimate the number of deposits remaining in a basin. ?? 1977.
Sagittal focusing Laue monochromator
Zhong,; Zhong, Hanson [Stony Brook, NY; Jonathan, Hastings [Wading River, NY; Jerome, Kao [Stanford, CA; Chi-Chang, Lenhard [Setauket, NY; Anthony, Siddons [Medford, NY; David Peter, Zhong [Cutchogue, NY; Hui, [Coram, NY
2009-03-24
An x-ray focusing device generally includes a slide pivotable about a pivot point defined at a forward end thereof, a rail unit fixed with respect to the pivotable slide, a forward crystal for focusing x-rays disposed at the forward end of the pivotable slide and a rearward crystal for focusing x-rays movably coupled to the pivotable slide and the fixed rail unit at a distance rearward from the forward crystal. The forward and rearward crystals define reciprocal angles of incidence with respect to the pivot point, wherein pivoting of the slide about the pivot point changes the incidence angles of the forward and rearward crystals while simultaneously changing the distance between the forward and rearward crystals.
NASA Astrophysics Data System (ADS)
Leonard, A. W.; McLean, A. G.; Makowski, M. A.; Stangeby, P. C.
2017-08-01
The midplane separatrix density is characterized in response to variations in upstream parallel heat flux density and central density through deuterium gas injection. The midplane density is determined from a high spatial resolution Thomson scattering diagnostic at the midplane with power balance analysis to determine the separatrix location. The heat flux density is varied by scans of three parameters, auxiliary heating, toroidal field with fixed plasma current, and plasma current with fixed safety factor, q 95. The separatrix density just before divertor detachment onset is found to scale consistent with the two-point model when radiative dissipation is taken into account. The ratio of separatrix to pedestal density, n e,sep/n e,ped varies from ⩽30% to ⩾60% over the dataset, helping to resolve the conflicting scaling of core plasma density limit and divertor detachment onset. The scaling of the separatrix density at detachment onset is combined with H-mode power threshold scaling to obtain a scaling ratio of minimum n e,sep/n e,ped expected in future devices.
The trigger mechanism of low-frequency earthquakes on Montserrat
NASA Astrophysics Data System (ADS)
Neuberg, J. W.; Tuffen, H.; Collier, L.; Green, D.; Powell, T.; Dingwell, D.
2006-05-01
A careful analysis of low-frequency seismic events on Soufrièere Hills volcano, Montserrat, points to a source mechanism that is non-destructive, repetitive, and has a stationary source location. By combining these seismological clues with new field evidence and numerical magma flow modelling, we propose a seismic trigger model which is based on brittle failure of magma in the glass transition. Loss of heat and gas from the magma results in a strong viscosity gradient across a dyke or conduit. This leads to a build-up of shear stress near the conduit wall where magma can rupture in a brittle manner, as field evidence from a rhyolitic dyke demonstrates. This brittle failure provides seismic energy, the majority of which is trapped in the conduit or dyke forming the low-frequency coda of the observed seismic signal. The trigger source location marks the transition from ductile conduit flow to friction-controlled magma ascent. As the trigger mechanism is governed by the depth-dependent magma parameters, the source location remains fixed at a depth where the conditions allow brittle failure. This is reflected in the fixed seismic source locations.
Giles, Thomas D; Weber, Michael A; Basile, Jan; Gradman, Alan H; Bharucha, David B; Chen, Wei; Pattathil, Manoj
2014-05-31
The fixed-dose combination of any two antihypertensive drugs from different drug classes is typically more effective in reducing blood pressure than a dose increase of component monotherapy. We assessed the efficacy and safety of a fixed-dose combination of a vasodilating β blocker (nebivolol) and an angiotensin II receptor blocker (valsartan) in adults with hypertension. We did an 8-week, phase 3, multicentre, randomised, double-blind, placebo-controlled, parallel-group trial at 401 US sites. Participants (age ≥18 years) with hypertension but with blood pressure less than 180/110 mm Hg were randomly assigned (2:2:2:2:2:2:2:1) by a 24-h interactive web response system in blocks of 15 to 4 weeks of double-blind treatment with nebivolol and valsartan fixed-dose combination (5 and 80 mg/day, 5 and 160 mg/day, or 10 and 160 mg/day), nebivolol (5 mg/day or 20 mg/day), valsartan (80 mg/day or 160 mg/day), or placebo. Doses were doubled in weeks 5-8; results are reported according to the final dose. Participants and research staff were masked to treatment allocation. The primary and key secondary endpoints were changes from baseline to week 8 in diastolic and systolic blood pressure, respectively. The primary statistical comparison was between the highest fixed-dose combination dose and the highest monotherapy doses; lower doses were then compared if this comparison was positive (Hochberg method for multiple testing). Efficacy analyses were by intention to treat. Safety assessments included monitoring of adverse events. Continuous efficacy parameters were analysed using an ANCOVA model; binary outcomes were analysed using a logistic regression model. This study is registered with ClinicalTrials.gov, NCT01508026. Between Jan 6, 2012, and March 15, 2013, 4161 patients were randomly assigned (277 to placebo and 554-555 to each active comparator group), 4118 of whom were included in the primary analysis. At week 8, the fixed-dose combination 20 and 320 mg/day group had significantly greater reductions in diastolic blood pressure from baseline than both nebivolol 40 mg/day (least-squares mean difference -1·2 mm Hg, 95% CI -2·3 to -0·1; p=0·030) and valsartan 320 mg/day (-4·4 mm Hg, -5·4 to -3·3; p<0·0001); all other comparisons were also significant, favouring the fixed-dose combinations (all p<0·0001). All systolic blood pressure comparisons were also significant (all p<0·01). At least one treatment-emergent adverse event was experienced by 30-36% of participants in each group. Nebivolol and valsartan fixed-dose combination is an effective and well-tolerated treatment option for patients with hypertension. Forest Research Institute. Copyright © 2014 Elsevier Ltd. All rights reserved.
van Rooij, Kim; de Leede, Leo; Frijlink, Henderik W.; Koppeschaar, Hans P. F.; Olivier, Berend; Tuiten, Adriaan
2016-01-01
Aim The aim was to compare the pharmacokinetic profiles of two formulations of a combination drug product containing 0.5 mg testosterone and 50 mg sildenafil for female sexual interest/arousal disorder. The prototype (formulation 1) consists of a testosterone solution for sublingual administration and a sildenafil tablet that is administered 2.5 h later. The dual route/dual release fixed dose combination tablet (formulation 2) employs a sublingual and an oral route for systemic uptake. This tablet has an inner core of sildenafil with a polymeric time delay coating and an outer polymeric coating containing testosterone. It was designed to increase dosing practicality and decrease potential temporal non‐adherence through circumventing the relatively complex temporal dosing scheme. Methods Twelve healthy premenopausal subjects received both formulations randomly on separate days. Blood was sampled frequently to determine the pharmacokinetics of free testosterone, total testosterone, dihydrotestosterone, sildenafil and N‐desmethyl‐sildenafil. Results Formulation 2 had a higher maximum concentration (C max) for testosterone, 8.06 ng ml–1 (95% confidence interval [CI] 6.84, 9.28) and higher area under the plasma concentration–time curve (AUC), 7.69 ng ml–1 h (95% CI 6.22, 9.16) than formulation 1, 5.66 ng ml–1 (95% CI 4.63, 6.69) and 5.12 ng ml–1 h (95% CI 4.51, 5.73), respectively. Formulation 2 had a lower C max for sildenafil, 173 ng ml–1 (95% CI 126, 220) and a lower AUC, 476 ng ml–1 h (95% CI 401, 551) than formulation 1, 268 ng ml–1 (95% CI 188, 348) and 577 ng ml–1 h (95% CI 462, 692), respectively. Formulation 2 released sildenafil after 2.75 h (95% CI 2.40, 3.10). Conclusions The dual route/dual release fixed dose combination tablet fulfilled its design criteria and is considered suitable for further clinical testing. What is Already Known about this Subject Female sexual interest/arousal disorder (FSIAD) is a significant problem impacting psychological well‐being, but the pharmacotherapeutic options for this problem are lacking.The combined, on‐demand, sublingual administration of low dose sublingual testosterone and oral administration of sildenafil is a novel pharmacotherapeutic option under development for FSIAD.In proof‐of‐concept trials, these compounds were successfully administered via different dosage forms (sublingual and oral) at different time points (separated by 2.5 h) because of their markedly different pharmacokinetic–pharmacodynamic profiles. For future larger scale studies and the clinical practice, this raises obvious adherence issues. What this Study Adds A newly developed dual route/dual release fixed dose combination tablet containing testosterone and sildenafil mimics the pharmacokinetic profile of these components when they are administered as different dosage forms, 2.5 h apart.This combination tablet is a suitable final pharmaceutical drug product that will be used in future studies. PMID:26804967
Kim, Young-Hoo; Park, Jang-Won; Kim, Jun-Shik; Kulkarni, Sourabh S; Kim, Yoon-Hong
2014-10-01
We are aware of no study that has compared press-fit condylar Sigma fixed-bearing and mobile-bearing total knee prostheses in the same patients after more than ten years of follow-up. The purpose of the current study was to compare these two implants with respect to the functional and radiographic results, prevalence of osteolysis, and overall revision rates at a mean of 12.1 years of follow-up. The study consisted of a consecutive series of 444 patients (mean age [and standard deviation], 66.5 ± 7.4 years) who underwent simultaneous bilateral total knee arthroplasty, with one side treated immediately after the other. All of the patients received a press-fit condylar Sigma mobile-bearing prosthesis on one side and a press-fit condylar Sigma fixed-bearing prosthesis on the contralateral side. The minimum duration of follow-up was ten years (mean, 12.1 years; range, ten to thirteen years). At the time of each follow-up visit, the patients were assessed clinically and radiographically. Postoperative total knee scores (95 and 94 points), Western Ontario and McMaster Universities Osteoarthritis Index (19 and 18 points), University of California, Los Angeles activity score (both prostheses, 5 points), range of motion (129° ± 6.3° and 127° ± 6.8°), and radiographic findings did not differ significantly between the press-fit condylar Sigma mobile and fixed-bearing designs at the final follow-up. The prevalence of aseptic loosening (1.4% and 1.8%) did not differ significantly between the mobile and fixed-bearing implant designs. No knee in either group had osteolysis. The estimated survival rate with revision as the end point was 98.2% (95% confidence interval, 91% to 99%) and 97.5% (95% confidence interval, 91% to 99%) at 12.1 years for the mobile and fixed-bearing implant groups, respectively. The results of the present long-term clinical study suggest that excellent clinical and radiographic results were achieved with both the press-fit condylar Sigma mobile and fixed-bearing cruciate-retaining total knee designs. We found no significant clinical advantage for a mobile-bearing over a fixed-bearing total knee prosthesis. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.
Standard map in magnetized relativistic systems: fixed points and regular acceleration.
de Sousa, M C; Steffens, F M; Pakter, R; Rizzato, F B
2010-08-01
We investigate the concept of a standard map for the interaction of relativistic particles and electrostatic waves of arbitrary amplitudes, under the action of external magnetic fields. The map is adequate for physical settings where waves and particles interact impulsively, and allows for a series of analytical result to be exactly obtained. Unlike the traditional form of the standard map, the present map is nonlinear in the wave amplitude and displays a series of peculiar properties. Among these properties we discuss the relation involving fixed points of the maps and accelerator regimes.
Fedosov differentials and Catalan numbers
NASA Astrophysics Data System (ADS)
Löffler, Johannes
2010-06-01
The aim of the paper is to establish a non-recursive formula for the general solution of Fedosov's 'quadratic' fixed-point equation (Fedosov 1994 J. Diff. Geom. 40 213-38). Fedosov's geometrical fixed-point equation for a differential is rewritten in a form similar to the functional equation for the generating function of Catalan numbers. This allows us to guess the solution. An adapted example for Kaehler manifolds of constant sectional curvature is considered in detail. Also for every connection on a manifold a familiar classical differential will be introduced. Dedicated to the memory of Nikolai Neumaier.
47 CFR 101.139 - Authorization of transmitters.
Code of Federal Regulations, 2013 CFR
2013-10-01
... SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.139 Authorization of transmitters. (a) Unless...-point microwave and point-to-multipoint services under this part must be a type that has been verified...
47 CFR 101.139 - Authorization of transmitters.
Code of Federal Regulations, 2014 CFR
2014-10-01
... SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.139 Authorization of transmitters. (a) Unless...-point microwave and point-to-multipoint services under this part must be a type that has been verified...
47 CFR 101.139 - Authorization of transmitters.
Code of Federal Regulations, 2012 CFR
2012-10-01
... SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.139 Authorization of transmitters. (a) Unless...-point microwave and point-to-multipoint services under this part must be a type that has been verified...
47 CFR 101.139 - Authorization of transmitters.
Code of Federal Regulations, 2011 CFR
2011-10-01
... SERVICES FIXED MICROWAVE SERVICES Technical Standards § 101.139 Authorization of transmitters. (a) Unless...-point microwave and point-to-multipoint services under this part must be a type that has been verified...
NASA Technical Reports Server (NTRS)
Holms, A. G.
1980-01-01
Population model coefficients were chosen to simulate a saturated 2 to the 4th fixed-effects experiment having an unfavorable distribution of relative values. Using random number studies, deletion strategies were compared that were based on the F-distribution, on an order statistics distribution of Cochran's, and on a combination of the two. The strategies were compared under the criterion of minimizing the maximum prediction error, wherever it occurred, among the two-level factorial points. The strategies were evaluated for each of the conditions of 0, 1, 2, 3, 4, 5, or 6 center points. Three classes of strategies were identified as being appropriate, depending on the extent of the experimenter's prior knowledge. In almost every case the best strategy was found to be unique according to the number of center points. Among the three classes of strategies, a security regret class of strategy was demonstrated as being widely useful in that over a range of coefficients of variation from 4 to 65%, the maximum predictive error was never increased by more than 12% over what it would have been if the best strategy had been used for the particular coefficient of variation. The relative efficiency of the experiment, when using the security regret strategy, was examined as a function of the number of center points, and was found to be best when the design used one center point.
Guven Yilmaz, Suzan; Degirmenci, Cumali; Karakoyun, Yunus Emre; Yusifov, Emil; Ates, Halil
2017-06-14
To evaluate the effect of bimatoprost/timolol maleate fixed combination (BTFC), latanoprost/timolol maleate fixed combination (LTFC), and travoprost/timolol maleate fixed combination (TTFC) on 24-h intraocular pressure (IOP) in patients with open-angle glaucoma. This prospective, observer-masked, randomized study included 50 patients with primary open-angle glaucoma. All patients were using hypotensive lipids and timolol maleate fixed combination treatment for ≥4 weeks and had an IOP ≤ 21 mmHg. Group 1 (n = 18) received BTFC, group 2 (n = 14) received LTFC, and group 3 (n = 18) received TTFC. All patients were hospitalized, and IOP was monitored for 24-h (10:00, 14:00, 18:00, 22:00, 02:00, and 06:00). Mean diurnal IOP variation measurements were taken between 06:00 and 18:00, and mean nocturnal IOP variation measurements were taken between 22:00 and 02:00. Mean IOP and IOP variation in the three groups were compared. Mean 24-h IOP did not differ significantly between the three groups (group 1: 14.6 ± 2.9 mmHg; group 2: 14.1 ± 3.7 mmHg and group 3: 15.8 ± 2.0 mmHg; P > 0.05). Mean diurnal IOP variation was 4.6 ± 2.3 mmHg in group 1, 5.8 ± 2.4 mmHg in group 2, and 4.3 ± 1.7 mmHg in group 3, and mean nocturnal IOP variation was 3.2 ± 2.8 mmHg in group 1, 2.9 ± 1.9 mmHg in group 2, and 3.0 ± 1.6 mmHg group 3. There were not any significant differences in diurnal or nocturnal IOP variation between the three groups (P < 0.05). All three fixed combinations effectively controlled IOP for 24-h and had a similar effect on diurnal and nocturnal IOP variations.
Polarizable six-point water models from computational and empirical optimization.
Tröster, Philipp; Lorenzen, Konstantin; Tavan, Paul
2014-02-13
Tröster et al. (J. Phys. Chem B 2013, 117, 9486-9500) recently suggested a mixed computational and empirical approach to the optimization of polarizable molecular mechanics (PMM) water models. In the empirical part the parameters of Buckingham potentials are optimized by PMM molecular dynamics (MD) simulations. The computational part applies hybrid calculations, which combine the quantum mechanical description of a H2O molecule by density functional theory (DFT) with a PMM model of its liquid phase environment generated by MD. While the static dipole moments and polarizabilities of the PMM water models are fixed at the experimental gas phase values, the DFT/PMM calculations are employed to optimize the remaining electrostatic properties. These properties cover the width of a Gaussian inducible dipole positioned at the oxygen and the locations of massless negative charge points within the molecule (the positive charges are attached to the hydrogens). The authors considered the cases of one and two negative charges rendering the PMM four- and five-point models TL4P and TL5P. Here we extend their approach to three negative charges, thus suggesting the PMM six-point model TL6P. As compared to the predecessors and to other PMM models, which also exhibit partial charges at fixed positions, TL6P turned out to predict all studied properties of liquid water at p0 = 1 bar and T0 = 300 K with a remarkable accuracy. These properties cover, for instance, the diffusion constant, viscosity, isobaric heat capacity, isothermal compressibility, dielectric constant, density, and the isobaric thermal expansion coefficient. This success concurrently provides a microscopic physical explanation of corresponding shortcomings of previous models. It uniquely assigns the failures of previous models to substantial inaccuracies in the description of the higher electrostatic multipole moments of liquid phase water molecules. Resulting favorable properties concerning the transferability to other temperatures and conditions like the melting of ice are also discussed.
Budesonide + formoterol fumarate dihydrate for the treatment of asthma.
Wolthers, Ole D
2016-01-01
One of the most widely used fixed combinations in asthma management is dry powder budesonide+formoterol fumarate dihydrate which is commercially available as Symbicort Turbuhaler(®) (and generic products), Easyhaler Bufomix(®) and DuoRespSpiromax(®) inhaler. The aim of this paper was to review the fixed dry powder combination of inhaled budesonide+formoterol fumarate dihydrate for asthma treatment in adolescents and adults. A literature search using relevant search terms, reference lists for reviews and meta-analyses was performed. In symptomatic adolescent and adult patients with asthma maintenance and reliever therapy with a single-inhaler fixed combination of dry powder budesonide+formoterol fumarate dihydrate is an evidenced option. The combination treatment is convenient to patients. It reduces the number of exacerbations requiring treatment with oral corticosteroids. In some patients the strategy may also reduce the total intake of inhaled corticosteroids over time. Whether important outcome measures of asthma treatment, such as hospital admission and emergency room visit rates, may be reduced is less well documented since the published studies may have been influenced by publication bias. Non-pharmaceutical company-sponsored research evaluating such measures is needed. There is no evidence for the use of single inhaler fixed combinations of inhaled corticosteroids+long-acting β(2)-agonists in children (<12 years of age), and budesonide+formoterol fumarate dihydrate should not be prescribed to the age group.
Connect-disconnect coupling for preadjusted rigid shafts
NASA Technical Reports Server (NTRS)
Bajkowski, F. W.; Holmberg, A.
1969-01-01
Coupling device enables a rigid shaft to be connected to or disconnected from a fixed base without disturbing the point of adjustment of the shaft in a socket or causing the shaft to rotate. The coupling consists of an externally threaded, internally slotted boss extending from the fixed base.
A complex fermionic tensor model in d dimensions
NASA Astrophysics Data System (ADS)
Prakash, Shiroman; Sinha, Ritam
2018-02-01
In this note, we study a melonic tensor model in d dimensions based on three-index Dirac fermions with a four-fermion interaction. Summing the melonic diagrams at strong coupling allows one to define a formal large- N saddle point in arbitrary d and calculate the spectrum of scalar bilinear singlet operators. For d = 2 - ɛ the theory is an infrared fixed point, which we find has a purely real spectrum that we determine numerically for arbitrary d < 2, and analytically as a power series in ɛ. The theory appears to be weakly interacting when ɛ is small, suggesting that fermionic tensor models in 1-dimension can be studied in an ɛ expansion. For d > 2, the spectrum can still be calculated using the saddle point equations, which may define a formal large- N ultraviolet fixed point analogous to the Gross-Neveu model in d > 2. For 2 < d < 6, we find that the spectrum contains at least one complex scalar eigenvalue (similar to the complex eigenvalue present in the bosonic tensor model recently studied by Giombi, Klebanov and Tarnopolsky) which indicates that the theory is unstable. We also find that the fixed point is weakly-interacting when d = 6 (or more generally d = 4 n + 2) and has a real spectrum for 6 < d < 6 .14 which we present as a power series in ɛ in 6 + ɛ dimensions.
Power Laws, Scale Invariance and the Generalized Frobenius Series:
NASA Astrophysics Data System (ADS)
Visser, Matt; Yunes, Nicolas
We present a self-contained formalism for calculating the background solution, the linearized solutions and a class of generalized Frobenius-like solutions to a system of scale-invariant differential equations. We first cast the scale-invariant model into its equidimensional and autonomous forms, find its fixed points, and then obtain power-law background solutions. After linearizing about these fixed points, we find a second linearized solution, which provides a distinct collection of power laws characterizing the deviations from the fixed point. We prove that generically there will be a region surrounding the fixed point in which the complete general solution can be represented as a generalized Frobenius-like power series with exponents that are integer multiples of the exponents arising in the linearized problem. While discussions of the linearized system are common, and one can often find a discussion of power-series with integer exponents, power series with irrational (indeed complex) exponents are much rarer in the extant literature. The Frobenius-like series we encounter can be viewed as a variant of the rarely-discussed Liapunov expansion theorem (not to be confused with the more commonly encountered Liapunov functions and Liapunov exponents). As specific examples we apply these ideas to Newtonian and relativistic isothermal stars and construct two separate power series with the overlapping radius of convergence. The second of these power series solutions represents an expansion around "spatial infinity," and in realistic models it is this second power series that gives information about the stellar core, and the damped oscillations in core mass and core radius as the central pressure goes to infinity. The power-series solutions we obtain extend classical results; as exemplified for instance by the work of Lane, Emden, and Chandrasekhar in the Newtonian case, and that of Harrison, Thorne, Wakano, and Wheeler in the relativistic case. We also indicate how to extend these ideas to situations where fixed points may not exist — either due to "monotone" flow or due to the presence of limit cycles. Monotone flow generically leads to logarithmic deviations from scaling, while limit cycles generally lead to discrete self-similar solutions.
Co-C and Pd-C Eutectic Fixed Points for Radiation Thermometry and Thermocouple Thermometry
NASA Astrophysics Data System (ADS)
Wang, L.
2017-12-01
Two Co-C and Pd-C eutectic fixed point cells for both radiation thermometry and thermocouple thermometry were constructed at NMC. This paper describes details of the cell design, materials used, and fabrication of the cells. The melting curves of the Co-C and Pd-C cells were measured with a reference radiation thermometer realized in both a single-zone furnace and a three-zone furnace in order to investigate furnace effect. The transition temperatures in terms of ITS-90 were determined to be 1324.18 {°}C and 1491.61 {°}C with the corresponding combined standard uncertainty of 0.44 {°}C and 0.31 {°}C for Co-C and Pd-C, respectively, taking into account of the differences of two different types of furnaces used. The determined ITS-90 temperatures are also compared with that of INRIM cells obtained using the same reference radiation thermometer and the same furnaces with the same settings during a previous bilateral comparison exercise (Battuello et al. in Int J Thermophys 35:535-546, 2014). The agreements are within k=1 uncertainty for Co-C cell and k = 2 uncertainty for Pd-C cell. Shapes of the plateaus of NMC cells and INRIM cells are compared too and furnace effects are analyzed as well. The melting curves of the Co-C and Pd-C cells realized in the single-zone furnace are also measured by a Pt/Pd thermocouple, and the preliminary results are presented as well.
Random phase detection in multidimensional NMR.
Maciejewski, Mark W; Fenwick, Matthew; Schuyler, Adam D; Stern, Alan S; Gorbatyuk, Vitaliy; Hoch, Jeffrey C
2011-10-04
Despite advances in resolution accompanying the development of high-field superconducting magnets, biomolecular applications of NMR require multiple dimensions in order to resolve individual resonances, and the achievable resolution is typically limited by practical constraints on measuring time. In addition to the need for measuring long evolution times to obtain high resolution, the need to distinguish the sign of the frequency constrains the ability to shorten measuring times. Sign discrimination is typically accomplished by sampling the signal with two different receiver phases or by selecting a reference frequency outside the range of frequencies spanned by the signal and then sampling at a higher rate. In the parametrically sampled (indirect) time dimensions of multidimensional NMR experiments, either method imposes an additional factor of 2 sampling burden for each dimension. We demonstrate that by using a single detector phase at each time sample point, but randomly altering the phase for different points, the sign ambiguity that attends fixed single-phase detection is resolved. Random phase detection enables a reduction in experiment time by a factor of 2 for each indirect dimension, amounting to a factor of 8 for a four-dimensional experiment, albeit at the cost of introducing sampling artifacts. Alternatively, for fixed measuring time, random phase detection can be used to double resolution in each indirect dimension. Random phase detection is complementary to nonuniform sampling methods, and their combination offers the potential for additional benefits. In addition to applications in biomolecular NMR, random phase detection could be useful in magnetic resonance imaging and other signal processing contexts.
NASA Astrophysics Data System (ADS)
Zhan, Yuanzeng; Mao, Tianming; Gong, Fang; Wang, Difeng; Chen, Jianyu
2010-10-01
As an effective survey tool for oil spill detection, the airborne hyper-spectral sensor affords the potentiality for retrieving the quantitative information of oil slick which is useful for the cleanup of spilled oil. But many airborne hyper-spectral images are affected by sun glitter which distorts radiance values and spectral ratios used for oil slick detection. In 2005, there's an oil spill event leaking at oil drilling platform in The South China Sea, and an AISA+ airborne hyper-spectral image recorded this event will be selected for studying in this paper, which is affected by sun glitter terribly. Through a spectrum analysis of the oil and water samples, two features -- "spectral rotation" and "a pair of fixed points" can be found in spectral curves between crude oil film and water. Base on these features, an oil film information retrieval method which can overcome the influence of sun glitter is presented. Firstly, the radiance of the image is converted to normal apparent reflectance (NormAR). Then, based on the features of "spectral rotation" (used for distinguishing oil film and water) and "a pair of fixed points" (used for overcoming the effect of sun glitter), NormAR894/NormAR516 is selected as an indicator of oil film. Finally, by using a threshold combined with the technologies of image filter and mathematic morphology, the distribution and relative thickness of oil film are retrieved.
Reliability of unstable periodic orbit based control strategies in biological systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mishra, Nagender; Singh, Harinder P.; Hasse, Maria
2015-04-15
Presence of recurrent and statistically significant unstable periodic orbits (UPOs) in time series obtained from biological systems is now routinely used as evidence for low dimensional chaos. Extracting accurate dynamical information from the detected UPO trajectories is vital for successful control strategies that either aim to stabilize the system near the fixed point or steer the system away from the periodic orbits. A hybrid UPO detection method from return maps that combines topological recurrence criterion, matrix fit algorithm, and stringent criterion for fixed point location gives accurate and statistically significant UPOs even in the presence of significant noise. Geometry ofmore » the return map, frequency of UPOs visiting the same trajectory, length of the data set, strength of the noise, and degree of nonstationarity affect the efficacy of the proposed method. Results suggest that establishing determinism from unambiguous UPO detection is often possible in short data sets with significant noise, but derived dynamical properties are rarely accurate and adequate for controlling the dynamics around these UPOs. A repeat chaos control experiment on epileptic hippocampal slices through more stringent control strategy and adaptive UPO tracking is reinterpreted in this context through simulation of similar control experiments on an analogous but stochastic computer model of epileptic brain slices. Reproduction of equivalent results suggests that far more stringent criteria are needed for linking apparent success of control in such experiments with possible determinism in the underlying dynamics.« less
NASA Technical Reports Server (NTRS)
Dejarnette, F. R.
1984-01-01
Attention is given to a computer algorithm yielding the data required for a flight crew to navigate from an entry fix, about 100 nm from an airport, to a metering fix, and arrive there at a predetermined time, altitude, and airspeed. The flight path is divided into several descent and deceleration segments. Results for the case of a B-737 airliner indicate that wind and nonstandard atmospheric properties have a significant effect on the flight path and must be taken into account. While a range of combinations of Mach number and calibrated airspeed is possible for the descent segments leading to the metering fix, only small changes in the fuel consumed were observed for this range of combinations. A combination that is based on scheduling flexibility therefore seems preferable.
Investigations on Two Co-C Fixed-Point Cells Prepared at INRIM and LNE-Cnam
NASA Astrophysics Data System (ADS)
Battuello, M.; Florio, M.; Sadli, M.; Bourson, F.
2011-08-01
INRIM and LNE-Cnam agreed to undertake a collaboration aimed to verify, through the use of metal-carbon eutectic fixed-point cells, methods and facilities used for defining the transition temperature of eutectic fixed points and manufacturing procedures of cells. To this purpose and as a first step of the cooperation, a Co-C cell manufactured at LNE-Cnam was measured at INRIM and compared with a local cell. The two cells were of different designs: the INRIM cell of 10 cm3 inner volume and the LNE-Cnam one of 3.9 cm3. The external dimensions of the two cells were noticeably different, namely, 40 mm in length and 24 mm in diameter for the LNE-Cnam cell 3Co4 and 110 mm in length and 42 mm in diameter for the INRIM cell. Consequently, the investigation of the effect of temperature distributions in the heating furnace was undertaken by implementing the cells inside single-zone and three-zone furnaces. The transition temperature of the cell was determined at the two institutes making use of different techniques: at INRIM radiation scales at 900 nm, 950 nm, and 1.6 μm were realized from In to Cu and then used to define T 90(Co-C) by extrapolation. At LNE-Cnam, a radiance comparator based on a grating monochromator was used for the extrapolation from the Cu fixed point. This paper presents a comparative description of the cells and the manufacturing methods and the results in terms of equivalence between the two cells and melting temperatures determined at INRIM and LNE-Cnam.
Jiang, Jifa; Niu, Lei
2017-04-01
We study the asymptotic behavior of the competitive Leslie/Gower model (map) [Formula: see text]It is shown that T unconditionally admits a globally attracting 1-codimensional invariant hypersurface [Formula: see text], called carrying simplex, such that every nontrivial orbit is asymptotic to one in [Formula: see text]. More general and easily checked conditions to guarantee the existence of carrying simplex for competitive maps are provided. An equivalence relation is defined relative to local stability of fixed points on [Formula: see text] (the boundary of [Formula: see text]) on the space of all three-dimensional Leslie/Gower models. Using a formula on the sum of the indices of all fixed points on the carrying simplex for three-dimensional maps, we list the 33 stable equivalence classes in terms of simple inequalities on the parameters [Formula: see text] and [Formula: see text] and draw their orbits on [Formula: see text]. In classes 1-18, every nontrivial orbit tends to a fixed point on [Formula: see text]. In classes 19-25, each map possesses a unique positive fixed point which is a saddle on [Formula: see text], and hence Neimark-Sacker bifurcations do not occur. Neimark-Sacker bifurcation does occur within each of classes 26-31, while it does not occur in class 32. Each map from class 27 admits a heteroclinic cycle, which forms the boundary of [Formula: see text]. The criteria on the stability of heteroclinic cycles are also given. This classification makes it possible to further investigate various dynamical properties in respective class.
Dorsal bridge plating or transarticular screws for Lisfranc fracture dislocations.
Kirzner, N; Zotov, P; Goldbloom, D; Curry, H; Bedi, H
2018-04-01
Aims The aim of this retrospective study was to compare the functional and radiological outcomes of bridge plating, screw fixation, and a combination of both methods for the treatment of Lisfranc fracture dislocations. Patients and Methods A total of 108 patients were treated for a Lisfranc fracture dislocation over a period of nine years. Of these, 38 underwent transarticular screw fixation, 45 dorsal bridge plating, and 25 a combination technique. Injuries were assessed preoperatively according to the Myerson classification system. The outcome measures included the American Orthopaedic Foot and Ankle Society (AOFAS) score, the validated Manchester Oxford Foot Questionnaire (MOXFQ) functional tool, and the radiological Wilppula classification of anatomical reduction. Results Significantly better functional outcomes were seen in the bridge plate group. These patients had a mean AOFAS score of 82.5 points, compared with 71.0 for the screw group and 63.3 for the combination group (p < 0.001). Similarly, the mean Manchester Oxford Foot Questionnaire score was 25.6 points in the bridge plate group, 38.1 in the screw group, and 45.5 in the combination group (p < 0.001). Functional outcome was dependent on the quality of reduction (p < 0.001). A trend was noted which indicated that plate fixation is associated with a better anatomical reduction (p = 0.06). Myerson types A and C2 significantly predicted a poorer functional outcome, suggesting that total incongruity in either a homolateral or divergent pattern leads to worse outcomes. The greater the number of columns fixed the worse the outcome (p < 0.001). Conclusion Patients treated with dorsal bridge plating have better functional and radiological outcomes than those treated with transarticular screws or a combination technique. Cite this article: Bone Joint J 2018;100-B:468-74.
Drake, Marcus J; Chapple, Christopher; Sokol, Roman; Oelke, Matthias; Traudtner, Klaudia; Klaver, Monique; Drogendijk, Ted; Van Kerrebroeck, Philip
2015-02-01
Short-term trials have demonstrated the efficacy and safety of combination therapy using antimuscarinics and α-blockers in men with lower urinary tract symptoms (LUTS). The Study of Solifenacin Succinate and Tamsulosin Hydrochloride OCAS (oral controlled absorption system) in Males with Lower Urinary Tract Symptoms (NEPTUNE) II is the first long-term study using solifenacin (Soli) and the oral controlled absorption system formulation of tamsulosin (TOCAS). To evaluate long-term (up to 52 wk) safety and efficacy of flexible dosing of two fixed-dose combinations (FDC) of Soli plus TOCAS in men with moderate to severe storage symptoms and voiding symptoms. Patients with both storage and voiding LUTS, maximum urinary flow rate of 4.0-12.0 ml/s, prostate size <75 ml, and postvoid residuals ≤ 150 ml, who completed the 12-wk, double-blind NEPTUNE study could continue in the 40-wk, open-label NEPTUNE II study. FDC of Soli 6 mg plus TOCAS 0.4 mg, or Soli 9 mg plus TOCAS 0.4mg; patients could switch between doses in NEPTUNE II. Safety and efficacy data from NEPTUNE and NEPTUNE II were combined to cover a 52-wk period. Primary efficacy end points were total International Prostate Symptom Score (IPSS) and total urgency and frequency score (TUFS); secondary end points included IPSS storage and voiding subscores, micturition diary variables, and quality of life parameters. In all, 1066 men completed NEPTUNE and received one dose or more of study medication in NEPTUNE II. Treatment-emergent adverse events were reported in 499 (46.8%) patients who participated in NEPTUNE II; most were mild or moderate. Urinary retention occurred in 13 of 1208 (1.1%) patients receiving one or more FDCs in NEPTUNE and/or NEPTUNE II; 8 (0.7%) required catheterisation (acute urinary retention [AUR]). Reductions in total IPSS and TUFS during NEPTUNE were maintained for up to 52 wk of FDC treatment, with mean reductions of 9.0 (standard deviation [SD]: 5.7) and 10.1 (SD: 9.2), respectively, from baseline to end of treatment. Clinically relevant improvements were also observed for secondary efficacy end points. Long-term treatment with FDC Soli plus TOCAS was well tolerated and efficacious in men with storage and voiding LUTS, with a low incidence of AUR. Treatment with solifenacin plus tamsulosin in a fixed-dose combination tablet was well tolerated by men with lower urinary tract symptoms. Improvements in symptoms were achieved after 4 wk of treatment, with further improvements at week 16 maintained for up to 52 wk throughout the study. Copyright © 2014 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Luszczki, Jarogniew J; Zagaja, Mirosław; Miziak, Barbara; Florek-Luszczki, Magdalena; Czuczwar, Stanislaw J
2015-01-01
To assess interactions between retigabine and levetiracetam in suppressing maximal electroshock-induced tonic seizures in Albino Swiss mice, type II isobolographic analysis was used. Total brain antiepileptic drug concentrations were measured with high pressure liquid chromatography. The combinations of retigabine with levetiracetam at the fixed-ratios of 1:5 and 1:10 were supra-additive (synergistic; p < 0.05) in terms of seizure suppression, while the combinations at the fixed-ratios of 1:1 and 1:2 were additive. No pharmacokinetic changes in total brain concentrations of levetiracetam and retigabine were documented, indicating the pharmacodynamic nature of interaction between these antiepileptic drugs in the mouse maximal electroshock-induced tonic seizure model. The combination of retigabine with levetiracetam at the fixed-ratios of 1:5 and 1:10 appears to be particularly beneficial combination exerting supra-additive interaction in suppressing maximal electroshock-induced tonic seizures. © 2015 S. Karger AG, Basel.
Nguyen, Tuyet A; Eichenfield, Lawrence F
2015-01-01
Acne vulgaris is a common and chronic skin disease, and is a frequent source of morbidity for affected patients. Treatment of acne vulgaris is often difficult due to the multifactorial nature of this disease. Combination therapy, such as that containing clindamycin and benzoyl peroxide, has become the standard of care. Several fixed formulations of clindamycin 1% and benzoyl peroxide of varying concentrations are available and have been used with considerable success. The major limitation is irritation and dryness from higher concentrations of benzoyl peroxide, and a combination providing optimal efficacy and tolerability has yet to be determined. Recently, a clindamycin and benzoyl peroxide 3.75% fixed combination formulation was developed. Studies have suggested that this formulation may be a safe and effective treatment regimen for patients with acne vulgaris. Here, we provide a brief review of acne pathogenesis, benzoyl peroxide and clindamycin, and profile a new Clindamycin-BP 3.75% fixed combination gel for the treatment of moderate-to-severe acne vulgaris. PMID:26604811
Prescription of fixed dose combination drugs for diarrhoea.
Chakrabarti, Amit
2007-01-01
Fixed-dose combinations (FDCs) of an antiprotozoal and an antibacterial, for treatment of diarrhoea, have been available in the Indian pharmaceutical market for about a decade. There is little evidence to substantiate this combination therapy. We evaluated 2,163 physician prescriptions for diarrhoea and found that 59 per cent of prescriptions were for FDCs. This is unethical because prescribing such combinations exposes a patient to higher risks of adverse drug reactions and also increases the chances of drug resistance. Physicians' prescribing practices in India are influenced by socioeconomic factors and the pharmaceutical industry's marketing techniques that include giving incentives to physicians to prescribe certain drugs.
Fixed-dose combination of sitagliptin and metformin for the treatment of type 2 diabetes
Reynolds, Jonathan K
2009-01-01
JanumetTM, a fixed dose combination of sitagliptin/metformin HCL manufactured by Merck Pharmaceuticals, has received US Food and Drug Administration approval for treatment of patients with type 2 diabetes, that are inadequately controlled, either by sitagliptin or metformin alone or together in free-dose combination form. Sitagliptin, an inhibitor of the enzyme DDP-4, assists patients with type 2 diabetes mellitus to achieve glycemic control. It has been shown to be safe and effective at 100 mg daily doses. The effect of giving sitagliptin in combination with metformin is thought to have a complimentary and possibly additive effect on glycemic control. PMID:21437126
Counting relative equilibrium configurations of the full two-body problem
NASA Astrophysics Data System (ADS)
Moeckel, Richard
2018-02-01
Consider a system of two rigid, massive bodies interacting according to their mutual gravitational attraction. In a relative equilibrium motion, the bodies rotate rigidly and uniformly about a fixed axis in R^3. This is possible only for special positions and orientations of the bodies. After fixing the angular momentum, these relative equilibrium configurations can be characterized as critical points of a smooth function on configuration space. The goal of this paper is to use Morse theory and Lusternik-Schnirelmann category theory to give lower bounds for the number of critical points when the angular momentum is sufficiently large. In addition, the exact number of critical points and their Morse indices are found in the limit as the angular momentum tends to infinity.
NASA Astrophysics Data System (ADS)
Lahoche, Vincent; Ousmane Samary, Dine
2017-02-01
This paper is focused on the functional renormalization group applied to the T56 tensor model on the Abelian group U (1 ) with closure constraint. For the first time, we derive the flow equations for the couplings and mass parameters in a suitable truncation around the marginal interactions with respect to the perturbative power counting. For the second time, we study the behavior around the Gaussian fixed point, and show that the theory is nonasymptotically free. Finally, we discuss the UV completion of the theory. We show the existence of several nontrivial fixed points, study the behavior of the renormalization group flow around them, and point out evidence in favor of an asymptotically safe theory.
Dynamics of a durable commodity market involving trade at disequilibrium
NASA Astrophysics Data System (ADS)
Panchuk, A.; Puu, T.
2018-05-01
The present work considers a simple model of a durable commodity market involving two agents who trade stocks of two different types. Stock commodities, in contrast to flow commodities, remain on the market from period to period and, consequently, there is neither unique demand function nor unique supply function exists. We also set up exact conditions for trade at disequilibrium, the issue being usually neglected, though a fact of reality. The induced iterative system has infinite number of fixed points and path dependent dynamics. We show that a typical orbit is either attracted to one of the fixed points or eventually sticks at a no-trade point. For the latter the stock distribution always remains the same while the price displays periodic or chaotic oscillations.
Ali Khawaja, Ranish Deedar; Singh, Sarabjeet; Padole, Atul; Otrakji, Alexi; Lira, Diego; Zhang, Da; Liu, Bob; Primak, Andrew; Xu, George; Kalra, Mannudeep K
2017-08-01
To determine the effect of patient off-centering on point organ radiation dose measurements in a human cadaver scanned with routine abdominal CT protocol. A human cadaver (88 years, body-mass-index 20 kg/m2) was scanned with routine abdominal CT protocol on 128-slice dual source MDCT (Definition Flash, Siemens). A total of 18 scans were performed using two scan protocols (a) 120 kV-200 mAs fixed-mA (CTDIvol 14 mGy) (b) 120 kV-125 ref mAs (7 mGy) with automatic exposure control (AEC, CareDose 4D) at three different positions (a) gantry isocenter, (b) upward off-centering and (c) downward off-centering. Scanning was repeated three times at each position. Six thimble (in liver, stomach, kidney, pancreas, colon and urinary bladder) and four MOSFET dosimeters (on cornea, thyroid, testicle and breast) were placed for calculation of measured point organ doses. Organ dose estimations were retrieved from dose-tracking software (eXposure, Radimetrics). Statistical analysis was performed using analysis of variance. There was a significant difference between the trends of point organ doses with AEC and fixed-mA at all three positions (p < 0.01). Variation in point doses between fixed-mA and AEC protocols were statistically significant across all organs at all Table positions (p < 0.001). There was up to 5-6% decrease in point doses with upward off-centering and in downward off-centering. There were statistical significant differences in point doses from dosimeters and dose-tracking software (mean difference for internal organs, 5-36% for fixed-mA & 7-48% for AEC protocols; p < 0.001; mean difference for surface organs, >92% for both protocols; p < 0.0001). For both protocols, the highest mean difference in point doses was found for stomach and lowest for colon. Measured absorbed point doses in abdominal CT vary with patient-centering in the gantry isocenter. Due to lack of consideration of patient positioning in the dose estimation on automatic software-over estimation of the doses up to 92% was reported. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Upadhyaya, Cheerag D; Wu, Jau-Ching; Trost, Gregory; Haid, Regis W; Traynelis, Vincent C; Tay, Bobby; Coric, Domagoj; Mummaneni, Praveen V
2012-03-01
There are now 3 randomized, multicenter, US FDA investigational device exemption, industry-sponsored studies comparing arthroplasty with anterior cervical discectomy and fusion (ACDF) for single-level cervical disease with 2 years of follow-up. These 3 studies evaluated the Prestige ST, Bryan, and ProDisc-C artificial discs. The authors analyzed the combined results of these trials. A total of 1213 patients with symptomatic, single-level cervical disc disease were randomized into 2 treatment arms in the 3 randomized trials. Six hundred twenty-one patients received an artificial cervical disc, and 592 patients were treated with ACDF. In the three trials, 94% of the arthroplasty group and 87% of the ACDF group have completed 2 years of follow-up. The authors analyzed the 2-year data from these 3 trials including previously unpublished source data. Statistical analysis was performed with fixed and random effects models. The authors' analysis revealed that segmental sagittal motion was preserved with arthroplasty (preoperatively 7.26° and postoperatively 8.14°) at the 2-year time point. The fusion rate for ACDF at 2 years was 95%. The Neck Disability Index, 36-Item Short Form Health Survey Mental, and Physical Component Summaries, neck pain, and arm pain scores were not statistically different between the groups at the 24-month follow-up. The arthroplasty group demonstrated superior results at 24 months in neurological success (RR 0.595, I(2) = 0%, p = 0.006). The arthroplasty group had a lower rate of secondary surgeries at the 2-year time point (RR 0.44, I(2) = 0%, p = 0.004). At the 2-year time point, the reoperation rate for adjacent-level disease was lower for the arthroplasty group when the authors analyzed the combined data set using a fixed effects model (RR 0.460, I(2) = 2.9%, p = 0.030), but this finding was not significant using a random effects model. Adverse event reporting was too heterogeneous between the 3 trials to combine for analysis. Both anterior cervical discectomy and fusion as well as arthroplasty demonstrate excellent 2-year surgical results for the treatment of 1-level cervical disc disease with radiculopathy. Arthroplasty is associated with a lower rate of secondary surgery and a higher rate of neurological success at 2 years. Arthroplasty may be associated with a lower rate of adjacent-level disease at 2 years, but further follow-up and analysis are needed to confirm this finding.
Vynckier, An-Katrien; Voorspoels, Jody; Remon, Jean Paul; Vervaet, Chris
2016-05-01
This study aimed to design a fixed-dose combination dosage form which provides a sustained release profile for both the freely water-soluble metformin HCl and the poorly soluble gliclazide, two antidiabetic compounds used to treat diabetes mellitus. Hot-melt co-extrusion was used as an innovative manufacturing technique for a pharmaceutical fixed-dose combination product. In this way, a matrix formulation that sustained metformin release could be developed, despite the high drug load in the formulation and the freely soluble nature of the drug. It was clear that co-extrusion was perfectly suited to produce a fixed-dose combination product with adequate properties for each of the incorporated APIs. A coat layer, containing at least 30% CAPA(®) 6506 as a hydrophobic polymer, was necessary to adequately sustain the release of the highly dosed freely soluble drug from the 70% metformin HCl-loaded CAPA(®) 6506 core of the co-extrudate. To obtain a complete gliclazide release over 24-h solubilization in Kollidon(®) VA, added as a second polymer to the CAPA(®) 6506 in the coat, was needed. Both active pharmaceutical ingredients (APIs), which have different physicochemical characteristics, were formulated in a single dosage form, using co-extrusion. © 2016 Royal Pharmaceutical Society, Journal of Pharmacy and Pharmacology.
Kozobolis, Vassileios; Panos, Georgios D; Konstantinidis, Aristeidis; Labiris, Georgios
2017-03-10
To compare the efficiency of brinzolamide/brimonidine fixed combination vs the dorzolamide/timolol fixed combination. Forty-four eyes of 44 patients were divided in 2 groups treated either with dorzolamide/timolol twice a day (group A) or with brinzolamide/brimonidine twice a day (group B). Complete ophthalmic examination including Goldmann applanation tonometry was performed before treatment administration and 1, 4, 8, and 12 weeks afterwards. The intraocular pressure (IOP) was measured twice a day (morning at 9 AM and afternoon at 4 PM). At the end of the follow-up period (12 weeks), mean morning IOP reduction was 7.0 ± 2.8 mm Hg in group A and 8.4 ± 1.9 mm Hg in group B. A significant difference was found (p = 0.0343). In contrast, mean afternoon IOP reduction was 8.6 ± 2.7 mm Hg in group A and 7.9 ± 1.6 mm Hg in group B and no significant difference was found (p = 0.3413). No significant adverse effects were observed in either group. Brinzolamide/brimonidine seems to be an effective and safe alternative β-blocker free fixed combination, especially for patients with comorbidities, having its own antihypertensive profile.
Kim, Young-Hoo; Park, Jang-Won; Kim, Jun-Shik
2018-01-01
There is none, to our knowledge, about comparison of high-flexion fixed-bearing and high-flexion mobile-bearing total knee arthroplasties (TKAs) in the same patients. The purpose of this study was to determine whether clinical results; radiographic and computed tomographic scan results; and the survival rate of a high-flexion mobile-bearing TKA is better than that of a high-flexion fixed-bearing TKA. The present study consisted of 92 patients (184 knees) who underwent same-day bilateral TKA. Of those, 17 were men and 75 were women. The mean age at the time of index arthroplasty was 61.5 ± 8.3 years (range 52-65 years). The mean body mass index was 26.2 ± 3.3 kg/m 2 (range 23-34 kg/m 2 ). The mean follow-up was 11.2 years (range 10-12 years). The Knee Society knee scores (93 vs 92 points; P = .531) and function scores (80 vs 80 points; P = 1.000), WOMAC scores (14 vs 15 points; P = .972), and UCLA activity scores (6 vs 6 points; P = 1.000) were not different between the 2 groups at 12 years follow-up. There were no differences in any radiographic and CT scan parameters between the 2 groups. Kaplan-Meier survivorship of the TKA component was 98% (95% confidence interval, 93-100) in the high-flexion fixed-bearing TKA group and 99% (95% confidence interval, 94-100) in the high-flexion mobile-bearing TKA group 12 years after the operation. We found no benefit to mobile-bearing TKA in terms of pain, function, radiographic and CT scan results, and survivorship. Longer-term follow-up is necessary to prove the benefit of the high-flexion mobile-bearing TKA over the high-flexion fixed-bearing TKA. Copyright © 2017 Elsevier Inc. All rights reserved.
Fuwa, Masahiro; Ueda, Kenji; Akaishi, Takahiro; Yamashita, Naoko; Kirihara, Tomoko; Shimazaki, Atsushi; Mano, Hidetoshi; Kawazu, Kouichi
2016-01-01
To compare the safety and efficacy of fixed-dose tafluprost/timolol combination (Taf/T-FDC) with those of fixed-dose latanoprost/timolol combination (Lat/T-FDC) by measuring the intraocular pressure (IOP)-lowering effect, ocular pharmacokinetics, and ocular surface toxicity. The IOP-lowering effect of Taf/T-FDC and Lat/T-FDC in ocular normotensive monkeys was evaluated at 4 and 8 h after instillation in study A, at 12, 14, 16, and 18 h after instillation in study B, and at 24, 26, 28, and 30 h after instillation in study C. Drug penetration into the eye was evaluated by measuring the concentrations of timolol, tafluprost acid (active metabolic form of tafluprost), and latanoprost acid (active metabolic form of latanoprost) using liquid chromatography coupled with tandem mass spectrometry after single instillation of Taf/T-FDC or Lat/T-FDC to Sprague Dawley rats. Cytotoxicity following 1-30 min exposure of SV40-transformed human corneal epithelial cells to Taf/T-FDC or Lat/T-FDC was analyzed using 3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium assays. Undiluted and 10-fold diluted solutions of each FDC were evaluated. The IOP-lowering effect of Taf/T-FDC was almost equivalent to that of Lat/T-FDC at 4-8 h after instillation. The peak IOP reduction of Taf/T-FDC and Lat/T-FDC was observed at 8 h after instillation, and there is no difference between the two. The difference between them was observed at 24-30 h after instillation, and Taf/T-FDC demonstrated a significantly greater IOP-lowering effect than Lat/T-FDC at 24-30 h after instillation. The IOP-lowering effect of Taf/T-FDC was sustained up to 30 h after instillation, while that of Lat/T-FDC had almost disappeared at 28 h after instillation. Timolol concentrations in aqueous humor after Taf/T-FDC instillation were higher than those after Lat/T-FDC instillation (Cmax, 3870 ng/mL vs 1330 ng/mL; AUCinf, 3970 ng·h/mL vs 1250 ng·h/mL). The concentrations of tafluprost acid and latanoprost acid in aqueous humor after instillation of Taf/T-FDC and Lat/T-FDC, respectively, were similar to those after instillation of mono-preparations of tafluprost and latanoprost, respectively. The cytotoxic effect of Taf/T-FDC to the human corneal epithelial cells was significantly lower than that of Lat/T-FDC at all evaluated time points in both undiluted and 10-fold diluted FDCs. Taf/T-FDC provides increased IOP-lowering effect duration and lower potential ocular surface toxicity than Lat/T-FDC.
Fuwa, Masahiro; Ueda, Kenji; Akaishi, Takahiro; Yamashita, Naoko; Kirihara, Tomoko; Shimazaki, Atsushi; Mano, Hidetoshi; Kawazu, Kouichi
2016-01-01
Purpose To compare the safety and efficacy of fixed-dose tafluprost/timolol combination (Taf/T-FDC) with those of fixed-dose latanoprost/timolol combination (Lat/T-FDC) by measuring the intraocular pressure (IOP)-lowering effect, ocular pharmacokinetics, and ocular surface toxicity. Methods The IOP-lowering effect of Taf/T-FDC and Lat/T-FDC in ocular normotensive monkeys was evaluated at 4 and 8 h after instillation in study A, at 12, 14, 16, and 18 h after instillation in study B, and at 24, 26, 28, and 30 h after instillation in study C. Drug penetration into the eye was evaluated by measuring the concentrations of timolol, tafluprost acid (active metabolic form of tafluprost), and latanoprost acid (active metabolic form of latanoprost) using liquid chromatography coupled with tandem mass spectrometry after single instillation of Taf/T-FDC or Lat/T-FDC to Sprague Dawley rats. Cytotoxicity following 1–30 min exposure of SV40-transformed human corneal epithelial cells to Taf/T-FDC or Lat/T-FDC was analyzed using 3-(4,5-dimethylthiazol-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium assays. Undiluted and 10-fold diluted solutions of each FDC were evaluated. Results The IOP-lowering effect of Taf/T-FDC was almost equivalent to that of Lat/T-FDC at 4–8 h after instillation. The peak IOP reduction of Taf/T-FDC and Lat/T-FDC was observed at 8 h after instillation, and there is no difference between the two. The difference between them was observed at 24–30 h after instillation, and Taf/T-FDC demonstrated a significantly greater IOP-lowering effect than Lat/T-FDC at 24–30 h after instillation. The IOP-lowering effect of Taf/T-FDC was sustained up to 30 h after instillation, while that of Lat/T-FDC had almost disappeared at 28 h after instillation. Timolol concentrations in aqueous humor after Taf/T-FDC instillation were higher than those after Lat/T-FDC instillation (Cmax, 3870 ng/mL vs 1330 ng/mL; AUCinf, 3970 ng·h/mL vs 1250 ng·h/mL). The concentrations of tafluprost acid and latanoprost acid in aqueous humor after instillation of Taf/T-FDC and Lat/T-FDC, respectively, were similar to those after instillation of mono-preparations of tafluprost and latanoprost, respectively. The cytotoxic effect of Taf/T-FDC to the human corneal epithelial cells was significantly lower than that of Lat/T-FDC at all evaluated time points in both undiluted and 10-fold diluted FDCs. Conclusion Taf/T-FDC provides increased IOP-lowering effect duration and lower potential ocular surface toxicity than Lat/T-FDC. PMID:27383260
77 FR 16434 - Revocation of Multiple Domestic, Alaskan, and Hawaiian Compulsory Reporting Points
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-21
... previously removed from service and taken out of the FAA aeronautical database. The FAA is removing these... FAA's aeronautical database. This will avoid confusion and eliminate safety issues with existing fixes... and not contained in the FAA's aeronautical database as reporting points. The reporting points...
Quantum Electrodynamics in d=3 from the ε Expansion.
Di Pietro, Lorenzo; Komargodski, Zohar; Shamir, Itamar; Stamou, Emmanuel
2016-04-01
We study quantum electrodynamics in d=3 coupled to N_{f} flavors of fermions. The theory flows to an IR fixed point for N_{f} larger than some critical number N_{f}^{c}. For N_{f}≤N_{f}^{c}, chiral-symmetry breaking is believed to take place. In analogy with the Wilson-Fisher description of the critical O(N) models in d=3, we make use of the existence of a fixed point in d=4-2ε to study the three-dimensional conformal theory. We compute, in perturbation theory, the IR dimensions of fermion bilinear and quadrilinear operators. For small N_{f}, a quadrilinear operator can become relevant in the IR and destabilize the fixed point. Therefore, the epsilon expansion can be used to estimate N_{f}^{c}. An interesting novelty compared to the O(N) models is that the theory in d=3 has an enhanced symmetry due to the structure of 3D spinors. We identify the operators in d=4-2ε that correspond to the additional conserved currents at d=3 and compute their infrared dimensions.
NASA Astrophysics Data System (ADS)
Bellver-Cebreros, Consuelo; Rodriguez-Danta, Marcelo
2009-03-01
An apparently unnoticed analogy between the torque-free motion of a rotating rigid body about a fixed point and the propagation of light in anisotropic media is stated. First, a new plane construction for visualizing this torque-free motion is proposed. This method uses an intrinsic representation alternative to angular momentum and independent of the modulus of angular velocity ω. The equivalence between this plane construction and the well-known Poinsot's three-dimensional graphical procedure is also shown. From this equivalence, analogies have been found between the general plane wave equation (relation of dispersion) in anisotropic media and basic equations of torque-free motion of a rigid body about a fixed point. These analogies allow reciprocal transfer of results between optics and mechanics and, as an example, reinterpretation of the internal conical refraction phenomenon in biaxial media is carried out. This paper is intended as an interdisciplinary application of analogies for students and teachers in the context of intermediate physics courses at university level.
Implicit integration methods for dislocation dynamics
Gardner, D. J.; Woodward, C. S.; Reynolds, D. R.; ...
2015-01-20
In dislocation dynamics simulations, strain hardening simulations require integrating stiff systems of ordinary differential equations in time with expensive force calculations, discontinuous topological events, and rapidly changing problem size. Current solvers in use often result in small time steps and long simulation times. Faster solvers may help dislocation dynamics simulations accumulate plastic strains at strain rates comparable to experimental observations. Here, this paper investigates the viability of high order implicit time integrators and robust nonlinear solvers to reduce simulation run times while maintaining the accuracy of the computed solution. In particular, implicit Runge-Kutta time integrators are explored as a waymore » of providing greater accuracy over a larger time step than is typically done with the standard second-order trapezoidal method. In addition, both accelerated fixed point and Newton's method are investigated to provide fast and effective solves for the nonlinear systems that must be resolved within each time step. Results show that integrators of third order are the most effective, while accelerated fixed point and Newton's method both improve solver performance over the standard fixed point method used for the solution of the nonlinear systems.« less
Constructing Hopf bifurcation lines for the stability of nonlinear systems with two time delays
NASA Astrophysics Data System (ADS)
Nguimdo, Romain Modeste
2018-03-01
Although the plethora real-life systems modeled by nonlinear systems with two independent time delays, the algebraic expressions for determining the stability of their fixed points remain the Achilles' heel. Typically, the approach for studying the stability of delay systems consists in finding the bifurcation lines separating the stable and unstable parameter regions. This work deals with the parametric construction of algebraic expressions and their use for the determination of the stability boundaries of fixed points in nonlinear systems with two independent time delays. In particular, we concentrate on the cases for which the stability of the fixed points can be ascertained from a characteristic equation corresponding to that of scalar two-delay differential equations, one-component dual-delay feedback, or nonscalar differential equations with two delays for which the characteristic equation for the stability analysis can be reduced to that of a scalar case. Then, we apply our obtained algebraic expressions to identify either the parameter regions of stable microwaves generated by dual-delay optoelectronic oscillators or the regions of amplitude death in identical coupled oscillators.
Goldberg, Daniel N.; Narayanan, Sri Hari Krishna; Hascoet, Laurent; ...
2016-05-20
We apply an optimized method to the adjoint generation of a time-evolving land ice model through algorithmic differentiation (AD). The optimization involves a special treatment of the fixed-point iteration required to solve the nonlinear stress balance, which differs from a straightforward application of AD software, and leads to smaller memory requirements and in some cases shorter computation times of the adjoint. The optimization is done via implementation of the algorithm of Christianson (1994) for reverse accumulation of fixed-point problems, with the AD tool OpenAD. For test problems, the optimized adjoint is shown to have far lower memory requirements, potentially enablingmore » larger problem sizes on memory-limited machines. In the case of the land ice model, implementation of the algorithm allows further optimization by having the adjoint model solve a sequence of linear systems with identical (as opposed to varying) matrices, greatly improving performance. Finally, the methods introduced here will be of value to other efforts applying AD tools to ice models, particularly ones which solve a hybrid shallow ice/shallow shelf approximation to the Stokes equations.« less
Optimization of the thermogauge furnace for realizing high temperature fixed points
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, T.; Dong, W.; Liu, F.
2013-09-11
The thermogauge furnace was commonly used in many NMIs as a blackbody source for calibration of the radiation thermometer. It can also be used for realizing the high temperature fixed point(HTFP). According to our experience, when realizing HTFP we need the furnace provide relative good temperature uniformity to avoid the possible damage to the HTFP. To improve temperature uniformity in the furnace, the furnace tube was machined near the tube ends with a help of a simulation analysis by 'ansys workbench'. Temperature distributions before and after optimization were measured and compared at 1300 °C, 1700°C, 2500 °C, which roughly correspondmore » to Co-C(1324 °C), Pt-C(1738 °C) and Re-C(2474 °C), respectively. The results clearly indicate that through machining the tube the temperature uniformity of the Thermogage furnace can be remarkably improved. A Pt-C high temperature fixed point was realized in the modified Thermogauge furnace subsequently, the plateaus were compared with what obtained using old heater, and the results were presented in this paper.« less
Instantons in Self-Organizing Logic Gates
NASA Astrophysics Data System (ADS)
Bearden, Sean R. B.; Manukian, Haik; Traversa, Fabio L.; Di Ventra, Massimiliano
2018-03-01
Self-organizing logic is a recently suggested framework that allows the solution of Boolean truth tables "in reverse"; i.e., it is able to satisfy the logical proposition of gates regardless to which terminal(s) the truth value is assigned ("terminal-agnostic logic"). It can be realized if time nonlocality (memory) is present. A practical realization of self-organizing logic gates (SOLGs) can be done by combining circuit elements with and without memory. By employing one such realization, we show, numerically, that SOLGs exploit elementary instantons to reach equilibrium points. Instantons are classical trajectories of the nonlinear equations of motion describing SOLGs and connect topologically distinct critical points in the phase space. By linear analysis at those points, we show that these instantons connect the initial critical point of the dynamics, with at least one unstable direction, directly to the final fixed point. We also show that the memory content of these gates affects only the relaxation time to reach the logically consistent solution. Finally, we demonstrate, by solving the corresponding stochastic differential equations, that, since instantons connect critical points, noise and perturbations may change the instanton trajectory in the phase space but not the initial and final critical points. Therefore, even for extremely large noise levels, the gates self-organize to the correct solution. Our work provides a physical understanding of, and can serve as an inspiration for, models of bidirectional logic gates that are emerging as important tools in physics-inspired, unconventional computing.
Cross-sectional transport imaging in a multijunction solar cell
Haegel, Nancy M.; Ke, Chi -Wen; Taha, Hesham; ...
2016-12-01
Here, we combine a highly localized electron-beam point source excitation to generate excess free carriers with the spatial resolution of optical near-field imaging to map recombination in a cross-sectioned multijunction (Ga 0.5In 0.5P/GaIn 0.01As/Ge) solar cell. By mapping the spatial variations in emission of light for fixed generation (as opposed to traditional cathodoluminescence (CL), which maps integrated emission as a function of position of generation), it is possible to directly monitor the motion of carriers and photons. We observe carrier diffusion throughout the full width of the middle (GaInAs) cell, as well as luminescent coupling from point source excitation inmore » the top cell GaInP to the middle cell. Supporting CL and near-field photoluminescence (PL) measurements demonstrate the excitation-dependent Fermi level splitting effects that influence cross-sectioned spectroscopy results, as well as transport limitations on the spatial resolution of conventional cross-sectional far-field measurements.« less
Investigations at INRIM on a Pd-C cell manufactured by NPL
NASA Astrophysics Data System (ADS)
Battuello, M.; Florio, M.; Machin, G.
2011-10-01
One of a set of metal-carbon eutectic cells (a Pd-C cell, 1765 K) manufactured by NPL and used for a previous comparison of temperature scales with NIST has been investigated at INRIM. There it was implemented in two different furnaces, namely a single- and a three-zone, and measured with a standard radiation thermometer operating at 900 nm and 950 nm. Both ITS-90 and thermodynamic melting temperatures of the cell were determined by means of an extrapolation approach. The thermodynamic temperature differs by only -0.31 K from the NIST value whereas the ITS-90 temperature differs by only -0.46 K from the NPL value. The agreements, within the combined expanded uncertainties, are particularly significant, because of the different approach followed at INRIM, namely the extrapolation of multi-fixed-point scales (n = 3 and n = 4), as compared with a direct radiometric method at NIST and an ITS-90 realization traceable to the gold point at NPL.
Calibration of stereo rigs based on the backward projection process
NASA Astrophysics Data System (ADS)
Gu, Feifei; Zhao, Hong; Ma, Yueyang; Bu, Penghui; Zhao, Zixin
2016-08-01
High-accuracy 3D measurement based on binocular vision system is heavily dependent on the accurate calibration of two rigidly-fixed cameras. In most traditional calibration methods, stereo parameters are iteratively optimized through the forward imaging process (FIP). However, the results can only guarantee the minimal 2D pixel errors, but not the minimal 3D reconstruction errors. To address this problem, a simple method to calibrate a stereo rig based on the backward projection process (BPP) is proposed. The position of a spatial point can be determined separately from each camera by planar constraints provided by the planar pattern target. Then combined with pre-defined spatial points, intrinsic and extrinsic parameters of the stereo-rig can be optimized by minimizing the total 3D errors of both left and right cameras. An extensive performance study for the method in the presence of image noise and lens distortions is implemented. Experiments conducted on synthetic and real data demonstrate the accuracy and robustness of the proposed method.
Children's weight and participation in organized sports.
Quinto Romani, Annette
2011-11-01
Literature dealing with the impact of organized sports on children's weight has been marked by a lack of consensus. A major weakness characterizing most of this research is a lack of proper measurement methods. This paper seeks to fill an important knowledge gap through careful application of econometric methods. Estimations are carried out using data on 1,400 children attending 6th grade in 2008 in the municipality of Aalborg, Denmark. We use standard ordinary least squares (OLS) and class fixed effects to explore the effect of sports participation on body mass index (BMI) as well as underweight, overweight and obesity. Results indicate that participation in organized sports reduced BMI by 2.1%. Likewise it reduced the likelihood of being overweight by 8.2 percentage points and obese by 3.1 percentage points. It is the unique dataset combined with econometric methods that distinguishes our contribution from that of others in the field, thereby offering new insight. Results using statistically sound methods suggest that participation in organized sports has a beneficial effect on children's weight.
Kading, Rebekah; Crabtree, Mary; Miller, Barry
2013-04-01
Formaldehyde is routinely used to fix tissues in preparation for pathology studies, however concerns remain that treatment of tissues with cellular fixatives may not entirely inactivate infectious virus particles. This concern is of particular regulatory importance for research involving viruses that are classified as select agents such as Rift Valley fever virus (RVFV). Therefore, the specific aims of this study were to (1) assay RVFV-exposed Aedes aegypti mosquitoes fixed in 4% paraformaldehyde for the presence of infectious RVFV particles at various time points following infection and (2) demonstrate the utility of immunofluorescence assay (IFA) for the detection of RVFV antigen in various tissues of paraformaldehyde-fixed mosquitoes. Mosquitoes were administered an infectious blood meal containing one of two strains of RVFV, harvested at various time points following infection, intrathoracically inoculated with 4% paraformaldehyde, and fixed overnight at 4°C. The infection status of a subset of mosquitoes was verified by IFA on leg tissues prior to fixation, and infectivity of RVFV in fixed mosquito carcasses was determined by Vero cell plaque assay. Paraformaldehyde-fixed mosquitoes harvested 14 days post infection were also paraffin-embedded and sectioned for detection of RVFV antigen to particular tissues by IFA. None of the RVFV-exposed mosquitoes tested by Vero cell plaque assay contained infectious RVFV after fixation. Furthermore, incubation of mosquito sections with trypsin prior to antibody staining is recommended for optimal visualization of RVFV antigen in infected mosquito tissues by IFA. Published by Elsevier B.V.
Fixed Schedules Can Support 21st-Century Skills
ERIC Educational Resources Information Center
Formanack, Gail; Pietsch, Laura
2011-01-01
The common belief among school librarians is that a flexibly scheduled school library program as opposed to a fixed schedule program is the best choice. After all, there are distinct advantages to the flexible program: students are served at the point of need, skills are not taught in isolation, and collaborative lessons are developed with…
NASA Technical Reports Server (NTRS)
Varaiya, P. P.
1972-01-01
General discussion of the theory of differential games with two players and zero sum. Games starting at a fixed initial state and ending at a fixed final time are analyzed. Strategies for the games are defined. The existence of saddle values and saddle points is considered. A stochastic version of a differential game is used to examine the synthesis problem.
Investigation of the Parameters of Sealed Triple-Point Cells for Cryogenic Gases
NASA Astrophysics Data System (ADS)
Fellmuth, B.; Wolber, L.
2011-01-01
An overview of the parameters of a large number of sealed triple-point cells for the cryogenic gases hydrogen, oxygen, neon, and argon is given that have been determined within the framework of an international star intercomparison to optimize the measurement of melting curves as well as to establish complete and reliable uncertainty budgets for the realization of temperature fixed points. Special emphasis is given to the question, whether the parameters are primarily influenced by the cell design or the properties of the fixed-point samples. For explaining surprisingly large periods of the thermal recovery after the heat pulses of the intermittent heating through the melting range, a simple model is developed based on a newly defined heat-capacity equivalent, which considers the heat of fusion and a melting-temperature inhomogeneity. The analysis of the recovery using a graded set of exponential functions containing different time constants is also explained in detail.
Electron teleportation and statistical transmutation in multiterminal Majorana islands
NASA Astrophysics Data System (ADS)
Michaeli, Karen; Landau, L. Aviad; Sela, Eran; Fu, Liang
2017-11-01
We study a topological superconductor island with spatially separated Majorana modes coupled to multiple normal-metal leads by single-electron tunneling in the Coulomb blockade regime. We show that low-temperature transport in such a Majorana island is carried by an emergent charge-e boson composed of a Majorana mode and an electronic excitation in leads. This transmutation from Fermi to Bose statistics has remarkable consequences. For noninteracting leads, the system flows to a non-Fermi-liquid fixed point, which is stable against tunnel couplings anisotropy or detuning away from the charge-degeneracy point. As a result, the system exhibits a universal conductance at zero temperature, which is a fraction of the conductance quantum, and low-temperature corrections with a universal power-law exponent. In addition, we consider Majorana islands connected to interacting one-dimensional leads, and find different stable fixed points near and far from the charge-degeneracy point.
Procedures for Behavioral Experiments in Head-Fixed Mice
Guo, Zengcai V.; Hires, S. Andrew; Li, Nuo; O'Connor, Daniel H.; Komiyama, Takaki; Ophir, Eran; Huber, Daniel; Bonardi, Claudia; Morandell, Karin; Gutnisky, Diego; Peron, Simon; Xu, Ning-long; Cox, James; Svoboda, Karel
2014-01-01
The mouse is an increasingly prominent model for the analysis of mammalian neuronal circuits. Neural circuits ultimately have to be probed during behaviors that engage the circuits. Linking circuit dynamics to behavior requires precise control of sensory stimuli and measurement of body movements. Head-fixation has been used for behavioral research, particularly in non-human primates, to facilitate precise stimulus control, behavioral monitoring and neural recording. However, choice-based, perceptual decision tasks by head-fixed mice have only recently been introduced. Training mice relies on motivating mice using water restriction. Here we describe procedures for head-fixation, water restriction and behavioral training for head-fixed mice, with a focus on active, whisker-based tactile behaviors. In these experiments mice had restricted access to water (typically 1 ml/day). After ten days of water restriction, body weight stabilized at approximately 80% of initial weight. At that point mice were trained to discriminate sensory stimuli using operant conditioning. Head-fixed mice reported stimuli by licking in go/no-go tasks and also using a forced choice paradigm using a dual lickport. In some cases mice learned to discriminate sensory stimuli in a few trials within the first behavioral session. Delay epochs lasting a second or more were used to separate sensation (e.g. tactile exploration) and action (i.e. licking). Mice performed a variety of perceptual decision tasks with high performance for hundreds of trials per behavioral session. Up to four months of continuous water restriction showed no adverse health effects. Behavioral performance correlated with the degree of water restriction, supporting the importance of controlling access to water. These behavioral paradigms can be combined with cellular resolution imaging, random access photostimulation, and whole cell recordings. PMID:24520413
Chaos in a restricted problem of rotation of a rigid body with a fixed point
NASA Astrophysics Data System (ADS)
Borisov, A. V.; Kilin, A. A.; Mamaev, I. S.
2008-06-01
In this paper, we consider the transition to chaos in the phase portrait of a restricted problem of rotation of a rigid body with a fixed point. Two interrelated mechanisms responsible for chaotization are indicated: (1) the growth of the homoclinic structure and (2) the development of cascades of period doubling bifurcations. On the zero level of the area integral, an adiabatic behavior of the system (as the energy tends to zero) is noted. Meander tori induced by the break of the torsion property of the mapping are found.
NASA Astrophysics Data System (ADS)
Péli, Zoltán; Nagy, Sándor; Sailer, Kornel
2018-02-01
The effect of the O(partial4) terms of the gradient expansion on the anomalous dimension η and the correlation length's critical exponent ν of the Wilson-Fisher fixed point has been determined for the Euclidean 3-dimensional O( N) models with N≥ 2 . Wetterich's effective average action renormalization group method is used with field-independent derivative couplings and Litim's optimized regulator. It is shown that the critical theory is well approximated by the effective average action preserving O( N) symmetry with an accuracy of O(η).
Anisotropic Bianchi type-III model in Palatini f (R) gravity
NASA Astrophysics Data System (ADS)
Banik, Debika Kangsha; Banik, Sebika Kangsha; Bhuyan, Kalyan
2017-03-01
We derive exact solutions for anisotropic Bianchi type-III cosmological model in the Palatini formalism of f (R) gravity using Dynamical System Approach. For the f (R) of the form f(R) =R-β /Rn and f(R) =R+α Rm , we have found the fixed points describing the radiation-dominated, matter dominated and de Sitter evolution periods. Fixed points have also been found which have non-vanishing shear playing a very significant role in describing the anisotropy present in the early universe. In addition, we have also found that the spatial curvature affect isotropisation of this cosmological model.
Motion transitions of falling plates via quasisteady aerodynamics.
Hu, Ruifeng; Wang, Lifeng
2014-07-01
In this paper, we study the dynamics of freely falling plates based on the Kirchhoff equation and the quasisteady aerodynamic model. Motion transitions among fluttering, tumbling along a cusp-like trajectory, irregular, and tumbling along a straight trajectory are obtained by solving the dynamical equations. Phase diagrams spanning between the nondimensional moment of inertia and aerodynamic coefficients or aspect ratio are built to identify regimes for these falling styles. We also investigate the stability of fixed points and bifurcation scenarios. It is found that the transitions are all heteroclinic bifurcations and the influence of the fixed-point stability is local.
Using Technology to Unify Geometric Theorems about the Power of a Point
ERIC Educational Resources Information Center
Contreras, Jose N.
2011-01-01
In this article, I describe a classroom investigation in which a group of prospective secondary mathematics teachers discovered theorems related to the power of a point using "The Geometer's Sketchpad" (GSP). The power of a point is defines as follows: Let "P" be a fixed point coplanar with a circle. If line "PA" is a secant line that intersects…
Evolution of branch points for a laser beam propagating through an uplink turbulent atmosphere.
Ge, Xiao-Lu; Liu, Xuan; Guo, Cheng-Shan
2014-03-24
Evolution of branch points in the distorted optical field is studied when a laser beam propagates through turbulent atmosphere along an uplink path. Two categories of propagation events are mainly explored for the same propagation height: fixed wavelength with change of the turbulence strength and fixed turbulence strength with change of the wavelength. It is shown that, when the beam propagates to a certain height, the density of the branch-points reaches its maximum and such a height changes with the turbulence strength but nearly remains constant with different wavelengths. The relationship between the density of branch-points and the Rytov number is also given. A fitted formula describing the relationship between the density of branch-points and propagation height with different turbulence strength and wavelength is found out. Interestingly, this formula is very similar to the formula used for describing the Blackbody radiation in physics. The results obtained may be helpful for atmospheric optics, astronomy and optical communication.
Two-point correlation functions in inhomogeneous and anisotropic cosmologies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marcori, Oton H.; Pereira, Thiago S., E-mail: otonhm@hotmail.com, E-mail: tspereira@uel.br
Two-point correlation functions are ubiquitous tools of modern cosmology, appearing in disparate topics ranging from cosmological inflation to late-time astrophysics. When the background spacetime is maximally symmetric, invariance arguments can be used to fix the functional dependence of this function as the invariant distance between any two points. In this paper we introduce a novel formalism which fixes this functional dependence directly from the isometries of the background metric, thus allowing one to quickly assess the overall features of Gaussian correlators without resorting to the full machinery of perturbation theory. As an application we construct the CMB temperature correlation functionmore » in one inhomogeneous (namely, an off-center LTB model) and two spatially flat and anisotropic (Bianchi) universes, and derive their covariance matrices in the limit of almost Friedmannian symmetry. We show how the method can be extended to arbitrary N -point correlation functions and illustrate its use by constructing three-point correlation functions in some simple geometries.« less
Global Positioning System Antenna Fixed Height Tripod Adapter
NASA Technical Reports Server (NTRS)
Dinardo, Steven J.; Smith, Mark A.
1997-01-01
An improved Global Positioning em antenna adaptor allows fixed antenna height measurements by removably attaching an adaptor plate to a conventional surveyor's tripod. Antenna height is controlled by an antenna boom which is a fixed length rod. The antenna is attached to one end of the boom. The opposite end of the boom tapers to a point sized to fit into a depression at the center of survey markers. The boom passes through the hollow center of a universal ball joint which is mounted at the center of the adaptor plate so that the point of the rod can be fixed in the marker's central depression. The mountains of the ball joint allow the joint to be moved horizontally in any direction relative to the tripod. When the ball joint is moved horizontally, the angle between the boom and the vertical changes because the boom's position is fixed at its lower end. A spirit level attached to the rod allows an operator to determine when the boom is plumb. The position of the ball joint is adjusted horizontally until the boom is plumb. At that time the antenna is positioned exactly over the center of the monument and the elevation of the antenna is precisely set by the length of the boom.
Boon, Mathilde E.
2013-01-01
The Cellient Automated Cell Block System (Hologic) can be used to process cervical scrapes to paraffin sections. For the first study on this subject, cervical scrapes were fixed in the formalin-free fixative BoonFix. This pilot study was limited to cases classified as atypical squamous lesion of unknown significance (ASCUS) and high-grade squamous lesion (HSIL) as diagnosed in the ThinPrep slide. The Cellient paraffin sections were classified into negative, atypical, CIN 1, CIN 2, and CIN 3. Multiple HPV genotypes were encountered in 79% of the scrapes. This study showed that the Cellient system for paraffin sections can be combined with HPV testing thanks to the formalin-free BoonFix. In two additional studies it was shown that such samples can also be used for morphotyping the vaginal microbiome and preparing cytologic ThinPrep slides. PMID:23577033
Boon, Mathilde E
2013-01-01
The Cellient Automated Cell Block System (Hologic) can be used to process cervical scrapes to paraffin sections. For the first study on this subject, cervical scrapes were fixed in the formalin-free fixative BoonFix. This pilot study was limited to cases classified as atypical squamous lesion of unknown significance (ASCUS) and high-grade squamous lesion (HSIL) as diagnosed in the ThinPrep slide. The Cellient paraffin sections were classified into negative, atypical, CIN 1, CIN 2, and CIN 3. Multiple HPV genotypes were encountered in 79% of the scrapes. This study showed that the Cellient system for paraffin sections can be combined with HPV testing thanks to the formalin-free BoonFix. In two additional studies it was shown that such samples can also be used for morphotyping the vaginal microbiome and preparing cytologic ThinPrep slides.