Sample records for flask air samples

  1. Sampling, storage, and analysis of C2-C7 non-methane hydrocarbons from the US National Oceanic and Atmospheric Administration Cooperative Air Sampling Network glass flasks.

    PubMed

    Pollmann, Jan; Helmig, Detlev; Hueber, Jacques; Plass-Dülmer, Christian; Tans, Pieter

    2008-04-25

    An analytical technique was developed to analyze light non-methane hydrocarbons (NMHC), including ethane, propane, iso-butane, n-butane, iso-pentane, n-pentane, n-hexane, isoprene, benzene and toluene from whole air samples collected in 2.5l-glass flasks used by the National Oceanic and Atmospheric Administration, Earth System Research Laboratory, Global Monitoring Division (NOAA ESRL GMD, Boulder, CO, USA) Cooperative Air Sampling Network. This method relies on utilizing the remaining air in these flasks (which is at below-ambient pressure at this stage) after the completion of all routine greenhouse gas measurements from these samples. NMHC in sample aliquots extracted from the flasks were preconcentrated with a custom-made, cryogen-free inlet system and analyzed by gas chromatography (GC) with flame ionization detection (FID). C2-C7 NMHC, depending on their ambient air mixing ratios, could be measured with accuracy and repeatability errors of generally < or =10-20%. Larger deviations were found for ethene and propene. Hexane was systematically overestimated due to a chromatographic co-elution problem. Saturated NMHC showed less than 5% changes in their mixing ratios in glass flask samples that were stored for up to 1 year. In the same experiment ethene and propene increased at approximately 30% yr(-1). A series of blank experiments showed negligible contamination from the sampling process and from storage (<10 pptv yr(-1)) of samples in these glass flasks. Results from flask NMHC analyses were compared to in-situ NMHC measurements at the Global Atmospheric Watch station in Hohenpeissenberg, Germany. This 9-months side-by-side comparison showed good agreement between both methods. More than 94% of all data comparisons for C2-C5 alkanes, isoprene, benzene and toluene fell within the combined accuracy and precision objectives of the World Meteorological Organization Global Atmosphere Watch (WMO-GAW) for NMHC measurements.

  2. Flask sample measurements for CO2, CH4 and CO using cavity ring-down spectrometry

    NASA Astrophysics Data System (ADS)

    Wang, J.-L.; Jacobson, G.; Rella, C. W.; Chang, C.-Y.; Liu, I.; Liu, W.-T.; Chew, C.; Ou-Yang, C.-F.; Liao, W.-C.; Chang, C.-C.

    2013-08-01

    In recent years, cavity ring-down spectrometry (CRDS) has been demonstrated to be a highly sensitive, stable and fast analytical technique for real-time in situ measurements of greenhouse gases. In this study, we propose the technique (which we call flask-CRDS) of analyzing whole air flask samples for CO2, CH4 and CO using a custom gas manifold designed to connect to a CRDS analyzer. Extremely stable measurements of these gases can be achieved over a large pressure range in the flask, from 175 to 760 Torr. The wide pressure range is conducive to flask sample measurement in three ways: (1) flask samples can be collected in low-pressure environments (e.g. high-altitude locations); (2) flask samples can be first analyzed for other trace gases with the remaining low-pressure sample for CRDS analysis of CO2, CH4 and CO; and (3) flask samples can be archived and re-analyzed for validation. The repeatability of this method (1σ of 0.07 ppm for CO2, 0.4 ppb for CH4, and 0.5 ppb for CO) was assessed by analyzing five canisters filled with the same air sample to a pressure of 200 Torr. An inter-comparison of the flask-CRDS data with in-situ CRDS measurements at a high-altitude mountain baseline station revealed excellent agreement, with differences of 0.10 ± 0.09 ppm (1σ) for CO2 and 0.9 ± 1.0 ppb for CH4. This study demonstrated that the flask-CRDS method was not only simple to build and operate but could also perform highly accurate and precise measurements of atmospheric CO2, CH4 and CO in flask samples.

  3. Atmospheric Hydrogen (H2) Concentrations from the CSIRO GASLAB Flask Sampling Network (1992 - 2001)

    DOE Data Explorer

    Steele, L. P. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Atmospheric Research, Aspendale, Victoria, Australia; Krummel, P. B. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Atmospheric Research, Aspendale, Victoria, Australia; Langenfelds, R. L. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Atmospheric Research, Aspendale, Victoria, Australia

    2003-01-01

    Air samples from nine sites were collected from the CSIRO GASLAB Flask Sampling Network for the purpose of monitoring the atmospheric hydrogen (H2) concentrations. The listed data were obtained from flask air samples returned to the CSIRO GASLAB for analysis. Typical sample storage times ranged from days to weeks for some sites (e.g., Cape Grim) to as much as one year for Macquarie Island and the Antarctic sites. Experiments carried out to test for any change in sample H22 mixing ratio during storage have shown no consistent and systematic drift in these flask types over test periods of several months to years (Cooper et al., 1999). An annual cycle of H2 is evident, reflecting the seasonal nature of some of the major sources and sinks (Novelli et al., 1999).

  4. Delta 13C in CO2 at Alert, NWT, Canada (June 1991 - December 2001)

    DOE Data Explorer

    Allison, C. E. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Aspendale, Victoria, Australia; Francey, R. J. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Aspendale, Victoria, Australia; Krummel, P. B. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Aspendale, Victoria, Australia

    2003-04-01

    Measurements have been made on air collected in flasks at Alert, Canada, through the CSIRO GASLAB worldwide network. Flasks are filled with air at Alert and returned to the CSIRO GASLAB for analysis; typical sample storage times for flasks collected at Alert range from a few weeks to a few months. No significant effect on the stable carbon isotopic composition, δ13C, has been detected as a consequence of the sample storage time.

  5. New Generation Flask Sampling Technology Final Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, James R.

    Scientists are turning their focus to the Arctic, site of one of the strongest climate change signals. A new generation of technologies is required to function within that harsh environment, chart evolution of its trace gases and provide new kinds of information for models of the atmosphere. Our response to the solicitation tracks how global atmospheric monitoring was launched more than a half century ago; namely, acquisition of discrete samples of air by flask and subsequent analysis in the laboratory. AOS is proposing to develop a new generation of flask sampling technology. It will enable the new Arctic programs tomore » begin with objective high density sampling of the atmosphere by UAS. The Phase I program will build the prototype flask technology and show that it can acquire and store mol fractions of CH4 and CO2 and value of δ13C with good fidelity. A CAD model will be produced for the entire platform including a package with 100 flasks and the airframe with auto-pilot, electronic propulsion and ground-to-air communications. A mobile flask analysis station will be prototyped in Phase I and designed to final form in Phase II. It expends very small sample per analysis and will interface directly to the flask package integrated permanently into the UAS fuselage. Commercial Applications and Other Benefits: • The New Generation Flask Sampling Technology able to provide a hundred or more samples of air per UAS mission. • A mobile analysis station expending far less sample than the existing ones and small enough to be stationed at the remote sites of Arctic operations. • A new form of validation for continuous trace gas observations from all platforms including the small UAS. • Further demonstration to potential customers of the AOS capabilities to invent, build, deploy and exploit entire platforms for observations of Earth’s atmosphere and ocean. Key Words: Flask Sampler, Mobile Analysis Station, Trace Gas, CO2, CH4, δC13, UAS, Baseline Airborne Observatory, Arctic, Climate Change. Summary for Members of Congress: The air, land and sea of the Arctic combine to produce a large climate change signal. AOS is proposing to develop unmanned airborne technologies able to begin prompt, objective observations of the signal’s atmospheric component.« less

  6. Atmospheric Carbon Dioxide Record from Flask Measurements at Lampedusa Island (May 1992- December 2000)

    DOE Data Explorer

    Chamard, Paolo [ENEA, GEM-CLIM, Rome, Italy; Ciattaglia, Luigi [ENEA, GEM-CLIM, Rome, Italy; di Sarra, Alcide [ENEA, GEM-CLIM, Rome, Italy; Monteleone, Francesco [ENEA, GEM-CLIM, Rome, Italy

    2001-01-01

    Lampedusa Station rests on a rocky seashore on the eastern tip of Lampedusa Island, located south of Sicily in the central Mediterranean Sea. Air samples at Lampedusa Station are collected each Friday in two pairs of 2-L glass flasks. Flasks are evacuated and then pressurized to 280-300 kPa with ambient air at the sampling site. Determinations of CO2 are made by using a Siemens Ultramat 5E nondispersive infrared gas analyzer. Water vapor is removed during the sampling process by means of a chemical trap (Magnesium Perchlorate). During the measurement, residual water vapor is removed by means of a cold trap at -70°C. From the inception of the monitoring program at Lampedusa Station, CO2-in-synthetic air calibration gases have been used. Values are relative to the dry air WMO mole fraction scale.

  7. ARM-LBNL-NOAA Flask Sampler for Carbon Cycle Gases

    DOE Data Explorer

    Torn, Margaret

    2008-01-15

    Data from ccg-flasks are sampled at the ARM SGP site and analyzed by the NOAA Earth System Research Laboratory (ESRL) as part of the NOAA Cooperative Global Air Sampling Network. Surface samples are collected from a 60m tower at the SGP Central Facility, usually once per week on one afternoon. The aircraft samples are collected approximately weekly from a chartered aircraft, and the collection flight path is centered over the tower where the surface samples are collected. Samples are collected by the ARM/LBNL Carbon Project. CO2 flask data contains measurements of CO2 concentration and CO2 stable isotope ratios (13CO2 and C18OO) from flasks collected at the SGP site. The flask samples are collected at 2m, 4m, 25m, and 60m along the 60m tower.

  8. Atmospheric CO2 Records from Sites in the Scripps Institution of Oceanography (SIO) Air Sampling Network (1985 - 2007)

    DOE Data Explorer

    Keeling, R. F. [Scripps Institution of Oceanography (SIO) University of California, La Jolla, California (USA); Piper, S. C. [Scripps Institution of Oceanography (SIO) University of California, La Jolla, California (USA); Bollenbacher, A. F. [Scripps Institution of Oceanography (SIO) University of California, La Jolla, California (USA); Walker , J. S. [Scripps Institution of Oceanography (SIO) University of California, La Jolla, California (USA)

    2008-05-01

    At Alert weekly air samples are collected in 5-L evacuated glass flasks exposed in triplicate. Flasks are returned to the SIO for CO2 determinations, which are made using an Applied Physics Corporation nondispersive infrared gas analyzer. In May 1983, the CO2-in-N2 calibration gases were replaced with CO2-in-air calibration gases, which are currently used (Keeling et al. 2002). Data are in terms of the Scripps "03A" calibration scale. On the basis of flask samples collected at Alert and analyzed by SIO, the annual average of the fitted monthly concentrations CO2 rose from 348.48 ppmv in 1986 to 384.84 ppmv in 2007. This represents an average annual growth rate of 1.73 ppmv per year at Alert.

  9. Atmospheric Carbon Dioxide Mixing Ratios from the NOAA CMDL Carbon Cycle Cooperative Global Air Sampling Network (2009)

    DOE Data Explorer

    Conway, Thomas [NOAA Climate Monitoring and Diagnostics Laboratory, Boulder, CO (USA); Tans, Pieter [NOAA Climate Monitoring and Diagnostics Laboratory, Boulder, CO (USA)

    2009-01-01

    The National Oceanic and Atmospheric Administration's Climate Monitoring and Diagnostics Laboratory (NOAA/CMDL) has measured CO2 in air samples collected weekly at a global network of sites since the late 1960s. Atmospheric CO2 mixing ratios reported in these files were measured by a nondispersive infrared absorption technique in air samples collected in glass flasks. All CMDL flask samples are measured relative to standards traceable to the World Meteorological Organization (WMO) CO2 mole fraction scale. These measurements constitute the most geographically extensive, carefully calibrated, internally consistent atmospheric CO2 data set available and are essential for studies aimed at better understanding the global carbon cycle budget.

  10. The Microbial Degradation of TCE (Trichloroethylene).

    DTIC Science & Technology

    1987-04-01

    enrichment studies . All the sample flasks , including the controls, contained 14C in the 14C02 trap. The 14C measured in the control flask 14C02...layer compared to the controls. These data again suggested that TCE was being biologically modified. Those flasks flushed with air gave the first hard...only slightly soluble in water. All culture flasks were incubated at 250C for a minimum of a week. Results in the carbon and nitrogen source studies are

  11. Atmospheric Methane Mixing Ratios--The NOAA/CMDL Global Cooperative Air Sampling Network\\, 1983-1993

    DOE Data Explorer

    Dlugokencky, E. J. [National Oceanic and Atmospheric Administration, Boulder, Colorado (USA); Lang, P. M. [National Oceanic and Atmospheric Administration, Boulder, Colorado (USA); Masarie, K. A. [National Oceanic and Atmospheric Administration, Boulder, Colorado (USA); Steele, L. P. [Commonwealth Scientific and Industrial Research Organisation, Aspendale, Victoria, Australia

    1994-01-01

    This data base presents atmospheric methane (CH4) mixing ratios from flask air samples collected over the period 1983-1993 by the National Oceanic and Atmospheric Administration, Climate Monitoring and Diagnostics Laboratory's (NOAA/CMDL's) global cooperative air sampling network. Air samples were collected approximately once per week at 44 fixed sites (37 of which were still active at the end of 1993). Samples were also collected at 5 degree latitude intervals along shipboard cruise tracks in the Pacific Ocean between North America and New Zealand (or Australia) and at 3 degree latitude intervals along cruise tracks in the South China Sea between Singapore and Hong Kong. The shipboard measurements were made approximately every 3 weeks per latitude zone by each of two ships in the Pacific Ocean and approximately once every week per latitude zone in the South China Sea. All samples were analyzed for CH4 at the NOAA/CMDL laboratory in Boulder, Colorado, by gas chromatography with flame ionization detection, and each aliquot was referenced to the NOAA/CMDL methane standard scale. In addition to providing the complete set of atmospheric CH4 measurements from flask air samples collected at the NOAA/CMDL network sites, this data base also includes files which list monthly mean mixing ratios derived from the individual flask air measurements. These monthly summary data are available for 35 of the fixed sites and 21 of the shipboard sampling sites.

  12. Atmospheric CO2 Concentrations from the Commonwealth Scientific and Industrial Research Organization (CSIRO) GASLAB Flask Sampling Network (March 1991 - December 2006)

    DOE Data Explorer

    Steele, L. P. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Aspendale, Victoria, Australia; Krummel, P. B. [Commonwealth Scientific and Industrial Research Organization (CSIRO),; Langenfelds, R. L. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Aspendale, Victoria, Australia

    2008-01-01

    Individual measurements have been obtained from flask air samples returned to the CSIRO GASLAB. Typical sample storage times range from days to weeks for some sites (e.g. Cape Grim, Aircraft over Tasmania and Bass Strait) to as much as one year for Macquarie Island and the Antarctic sites. Experiments carried out to test for changes in sample CO2 mixing ratio during storage have shown significant drifts in some flask types over test periods of several months to years (Cooper et al., 1999). Corrections derived from the test results are applied to network data according to flask type. These measurements indicate a rise in annual average atmospheric CO2 concentration from 357.72 parts per million by volume (ppmv) in 1992 to 383.05 ppmv in 2006, or an increase in annual average of about 1.81 ppmv/year. These flask data may be compared with other flask measurements from the Scripps Institution of Oceanography, available through 2004 in TRENDS; both indicate an annual average increase of 1.72 ppmv/year throuth 2004. Differences may be attributed to different sampling times or days, different numbers of samples, and different curve-fitting techniques used to obtain monthly and annual average numbers from flask data. Measurement error in flask data is believed to be small (Masarie et al., 2001).

  13. Atmospheric CO2 Records from Sites in the Atmospheric Environment Service Air Sampling Network (1975 and 1994)

    DOE Data Explorer

    Trivett, N. B.A. [Atmospheric Environment Service, Downsview, Ontario, Canada; Hudec, V. C. [Atmospheric Environment Service, Downsview, Ontario, Canada; Wong, C. S. [Marine Carbon Research Centre, Institute of Ocean Sciences, Sidney, British Columbia, Canada

    1997-01-01

    From the mid-1970s through the mid-1990s, air samples were collected for the purposes of monitoring atmospheric CO2 from four sites in the AES air sampling network. Air samples were collected approximately once per week, between 12:00 and 16:00 local time, in a pair of evacuated 2-L thick-wall borosilicate glass flasks. Samples were collected under preferred conditions of wind speed and direction (i.e., upwind of the main station and when winds are strong and steady). The flasks were evacuated to pressures of ~1 × 10-4 mbar or 0.01 Pa prior to being sent to the stations. The airwas not dried during sample collection. The flask data from Alert show an increase in the annual atmospheric CO2 concentration from 341.35 parts per million by volume (ppmv) in 1981 to 357.21 ppmv in 1991. For Cape St. James, Trivett and Higuchi (1989) reported that the mean annual rate of increase, obtained from the slope of a least-squares regression line through the annual averages, was 1.43 ppmv per year. In August 1992, the weather station at Cape St. James was automated; as a result, the flask sampling program was discontinued at this site. Estevan Point, on the West Coast of Vancouver Island, was chosen as a replacement station. Sampling at Estevan Point started in 1992; thus, the monthly and annual CO2record from Estevan Point is too short to show any long-term trends. The sampling site at Sable Island, off the coast of Nova Scotia, was established in 1975. The flask data from Sable Island show an increase in the annual atmospheric CO2 concentration from 334.49 parts per million by volume (ppmv) in 1977 (the first full year of data) to 356.02 ppmv in 1990. For Sable Island, Trivett and Higuchi (1989) reported that the mean annual rate of increase, obtained from the slope of a least-squares regression line through the annual averages, was 1.48 ppmv per year.

  14. Collection and Analysis of Firn Air from the South Pole, 2001

    NASA Astrophysics Data System (ADS)

    Butler, J. H.; Montzka, S. A.; Battle, M.; Clarke, A. D.; Mondeel, D. J.; Lind, J. A.; Hall, B. D.; Elkins, J. W.

    2001-12-01

    In January 2001, we collected an archive of 20th century air from the firn (snowpack) at the South Pole. Samples were collected into separate pairs of 3L glass flasks for measurements of O2/N2 (Bowdoin/Princeton) and carbon cycle gases (CMDL); individual 3L stainless steel and glass flasks for measurements of halocarbons, N2O, SF6, and COS; large (33L) stainless steel canisters for maintaining an archive of air for future analyses; and a few canisters each for measurement of 14CH4 (NIWA/CSIRO) and very low-level analyses of SF6 (SIO). Although it was hoped to obtain air dating back to the turn of the century, the analyses suggest that the earliest date was 1925 for CO2 and the mid- to late teens for heavier gases such as methyl bromide or methyl chloride. This talk will compare the analyses of halocarbons in these recently collected samples to those of air in flasks sampled at the South Pole in 1995. We also will present some results for compounds not measured in the 1995 South Pole samples owing to a paucity of air. Measurements made of the same gases in the firn air at both ends of this six-year interval, along with real-time atmospheric measurements of the same gases, are useful in evaluating assumptions about diffusion in the firn and may allow for the direct calculation of diffusion coefficients at low temperatures. This, in turn, would improve age estimates for firn air samples. New measurements will add to our existing histories established for the 20th century from analyses of firn air samples collected in both Greenland and Antarctica.

  15. Measurements of Atmospheric Methane and 13C/12C of Atmospheric Methane from Flask Air Samples (1999)

    DOE Data Explorer

    Quay, Paul [School of Oceanography, University of Washington; Stutsman, Johnny [School of Oceanography, University of Washington

    1999-01-01

    This database offers precise measurements of atmospheric methane and 13C/12C in atmospheric methane from flask air samples collected at eight sites worldwide and aboard NOAA cruises in the Pacific Ocean. The eight sites include Olympic Peninsula, Washington; Cape Grim, Tasmania; Fraserdale, Ontario; Marshall Islands; Baring Head, New Zealand; Mauna Loa, Hawaii; Point Barrow, Alaska; and American Samoa. The measurements span the period 1988 to mid-1996. These data are useful for global methane budget analyses and for determining the atmospheric isotopic composition of methane. All isotopic measurements have been corrected for standard drift.

  16. Atmospheric CH4 Concentrations from the Commonwealth Scientific and Industrial Research Organization (CSIRO) GASLAB Flask Sampling Network (1984 - 2001)

    DOE Data Explorer

    Steele, L. P. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Aspendale, Victoria, Australia; Krummel, P. B. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Aspendale, Victoria, Australia; Langenfelds, R. L. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Aspendale, Victoria, Australia

    2003-01-01

    The listed data were obtained from flask air samples returned to the CSIRO GASLAB for analysis. Typical sample storage times ranged from days to weeks for some sites (e.g., Cape Grim) to as much as one year for Macquarie Island and the Antarctic sites. Experiments carried out to test for any change in sample CH4 mixing ratio during storage have shown no drift to within detection limits over test periods of several months to years (Cooper et al., 1999).

  17. Long-term greenhouse gas measurements from aircraft

    NASA Astrophysics Data System (ADS)

    Karion, A.; Sweeney, C.; Wolter, S.; Newberger, T.; Chen, H.; Andrews, A.; Kofler, J.; Neff, D.; Tans, P.

    2012-10-01

    In March 2009 the NOAA/ESRL/GMD Carbon Cycle and Greenhouse Gases Group collaborated with the US Coast Guard (USCG) to establish the Alaska Coast Guard (ACG) sampling site, a unique addition to NOAA's atmospheric monitoring network. This collaboration takes advantage of USCG bi-weekly Arctic Domain Awareness (ADA) flights, conducted with Hercules C-130 aircraft from March to November each year. NOAA has installed window-replacement inlet plates on two USCG C-130 aircraft and deploys a pallet with NOAA instrumentation on each ADA flight. Flights typically last 8 h and cover a very large area, traveling from Kodiak, AK in the south up to Barrow, AK in the north, and making altitude profiles near the coast as well as in the interior. NOAA instrumentation on each flight includes: a flask sampling system, a continuous CO2/CH4/CO/H2O analyzer, a continuous ozone analyzer, and an ambient temperature and humidity sensor. GPS time and location from the aircraft's navigation system are also collected. Air samples collected in flight are analyzed at NOAA/ESRL for the major greenhouse gases and a variety of halocarbons and hydrocarbons that influence climate, stratospheric ozone, and air quality. Instruments on this aircraft are designed and deployed to be able to collect air samples and data autonomously, so that NOAA personnel visit the site only for installation at the beginning of each season. We present an assessment of the cavity ring-down spectroscopy (CRDS) CO2/CH4/CO/H2O analyzer performance operating on an aircraft over a three-year period. We describe the overall system for making accurate greenhouse gas measurements using a CRDS analyzer on an aircraft with minimal operator interaction. Short and long-term stability of the CRDS analyzer over a seven-month deployment period is better than 0.15 ppm, 2 ppb, and 5 ppb for CO2, CH4, CO respectively, considering differences of on-board reference tank measurements from a laboratory calibration performed prior to deployment. This stability is not affected by variation in pressure or temperature during flight. Biases and standard deviations of comparisons with flask samples suggest that atmospheric variability, flask-to-flask variability, and possible flask sampling biases may be driving biases in the comparison between flasks and in-situ CRDS measurements.

  18. First 2 years of Atmospheric CO2 measurements in the Estany Llong plain (2100 masl, Parc Nacional d'Aigüestortes i Estany de Sant Maurici, Pyrenees, Catalonia, Spain).

    NASA Astrophysics Data System (ADS)

    Curcoll, Roger; Recolons, Montserrat; Font, Anna; Agraz, Laura; Parga, Elena; Bacardit, Montse; Camarero, Lluís.; Pueyo, Salva; Rodó, Xavier; Morguí, Josep Anton

    2010-05-01

    Since April 2009, air samples are being taken bi-weekly at 10 GMT in the plain of the Estany Llong at 2100 masl. Estany Llong air sampling site (ELL, 42°34'29''N 0°57'17''E) is a remote site situated in the SW principal valley of the Parc Nacional d'Aigüestortes i Estany de Sant Maurici. New Flask-sampling equipment for Remote Mountain Sites was developed by the Institut Català de Ciències del Clima (IC3) to allow flask sampling in extreme weather conditions and carrying the sampling equipment for more than 10 km without damaging flasks. Dry Air analysis for CO2 are done at the Laboratory of IC3 using two coupled modified IRGA Licor-7000, where both pressure and flow are externally controlled. Far away from populated areas, ELL site acts as a remote site, but it is also responding to discrete events as snow melting, summer cattle breeding on pastures and trekking frequentation. Series of CO2 obtained are included as part of Long Term Ecological Research (LTER) at the Parc Nacional d'Aigüestortes i Estany de Sant Maurici. In the long term, these measurements show the mountain ecosystems contribution and geomorphologic influence on the CO2 budget of the air masses crossing a mountain range.

  19. Effects of Water Vapor on the Data Quality of the Stable Oxygen Isotopic Ratio of Atmospheric Carbon Dioxide

    NASA Astrophysics Data System (ADS)

    Evans, C. U.; White, J. W.; Vaughn, B.; Tans, P. P.; Pardo, L.

    2007-12-01

    The stable oxygen isotopic ratio of carbon dioxide can potentially track fundamental indicators of environmental change such as the balance between photosynthesis and respiration on regional to global scales. The Stable Isotope Laboratory (SIL) at the Institute of Arctic and Alpine Research (INSTAAR), University of Colorado at Boulder, has measured the stable isotopes of atmospheric carbon dioxide from more than 60 NOAA/Earth System Research Laboratory (ESRL) air flask-sampling sites since the early 1990s. If air is sampled without drying, oxygen can exchange between carbon dioxide and water in the flasks, entirely masking the desired signal. An attempt to investigate how water vapor is affecting the δ18O signal is accomplished by comparing the SIL measurements with specific humidity, calculated from the National Climatic Data Center (NCDC) global integrated surface hourly temperature and dew point database, at the time of sampling. Analysis of sites where samples have been collected initially without drying, and subsequently with a drying kit, in conjunction with the humidity data, has led to several conclusions. Samples that initially appear isotopically unaltered, in that their δ18O values are within the expected range, are being subtly influenced by the water vapor in the air. At Bermuda and other tropical to semi-tropical sites, the 'wet' sampling values have a seasonal cycle that is strongly anti-correlated to the specific humidity, while the 'dry' values have a seasonal cycle that is shifted earlier than the specific humidity cycle by 1-2 months. The latter phasing is expected given the seasonal phasing between climate over the ocean and land, while the former is consistent with a small, but measurable isotope exchange in the flasks. In addition, we note that there is a strong (r > 0.96) correlation between the average specific humidity and the percent of rejected samples for 'wet' sampling. This presents an opportunity for determining a threshold of specific humidity, below which air flask samples can be trusted. This approach may allow segregation of suspect and trusted data, and thus provide an improved record of oxygen isotopic ratios of carbon dioxide over the past two decades.

  20. Atmospheric CO2 Concentrations from Aircraft for 1972-1981, CSIRO Monitoring Program

    DOE Data Explorer

    Beardsmore, David J. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Victoria, Australia; Pearman, Graeme I. [Commonwealth Scientific and Industrial Research Organization (CSIRO), Victoria, Australia

    2012-01-01

    From 1972 through 1981, air samples were collected in glass flasks from aircraft at a variety of latitudes and altitudes over Australia, New Zealand, and Antarctica. The samples were analyzed for CO2 concentrations with nondispersive infrared gas analysis. The resulting data contain the sampling dates, type of aircraft, flight number, flask identification number, sampling time, geographic sector, distance in kilometers from the listed distance measuring equipment (DME) station, station number of the radio navigation distance measuring equipment, altitude of the aircraft above mean sea level, sample analysis date, flask pressure, tertiary standards used for the analysis, analyzer used, and CO2 concentration. These data represent the first published record of CO2 concentrations in the Southern Hemisphere expressed in the WMO 1981 CO2 Calibration Scale and provide a precise record of atmospheric CO2 concentrations in the troposphere and lower stratosphere over Australia and New Zealand.

  1. ARM Carbon Cycle Gases Flasks at SGP Site

    DOE Data Explorer

    Biraud, Sebastien

    2013-03-26

    Data from flasks are sampled at the Atmospheric Radiation Measurement Program ARM, Southern Great Plains Site and analyzed by the National Oceanic and Atmospheric Administration NOAA, Earth System Research Laboratory ESRL. The SGP site is included in the NOAA Cooperative Global Air Sampling Network. The surface samples are collected from a 60 m tower at the ARM SGP Central Facility, usually once per week in the afternoon. The aircraft samples are collected approximately weekly from a chartered aircraft, and the collection flight path is centered over the tower where the surface samples are collected. The samples are collected by the ARM and LBNL Carbon Project.

  2. Carbon and oxygen isotope ratios of ecosystem respiration along an Oregon conifer transect: preliminary observations based on small-flask sampling.

    PubMed

    Ehleringer, J. R.; Cook, C. S.

    1998-01-01

    Isotope ratio analyses of atmospheric CO(2) at natural abundance have significant potential for contributing to our understanding of photosynthetic and respiration processes in forest ecosystems. Recent advances in isotope ratio mass spectrometry allow for rapid, on-line analysis of small volumes of CO(2) in air, and open new research opportunities at the ecophysiological, whole-organism, and atmospheric levels. Among the immediate applications are the carbon and oxygen isotope ratio analyses of carbon dioxide in atmospheric air. Routine analysis of carbon dioxide in air volumes of approximately 50-300 &mgr;l is accomplished by linking a commercially available, trace gas condenser and gas chromatograph to an isotope ratio mass spectrometer operated in continuous-flow mode. Samples collected in the field are stored in either gas-tight syringes or 100-ml flasks. The small sample volume required makes it possible to subsample the air in flasks for CO(2) and then to sample the remaining air volume for the analysis of the isotopic composition of either methane or nitrous oxide. Reliable delta(13)C and delta(18)O values can be obtained from samples collected and stored for 1-3 days. Longer-term storage, on the order of weeks, is possible for delta(13)C measurements without drift in the isotope ratio signal, and should also be possible for delta(18)O measurements. When linked with an infrared gas analyzer, pump and flask sampling system, it is feasible to sample CO(2) extensively in remote forest locations. The air-sampling system was used to measure the isotope ratios of atmospheric CO(2) and to conduct a regression analysis of the relationship between these two parameters. From the regression, we calculated the delta(13)C of ecosystem respiration of four coniferous ecosystems along a precipitation gradient in central Oregon. The ecosystems along the coast-to-interior Oregon (OTTER) gradient are dominated by spruce-hemlock forests at the wet, coastal sites (> 200 cm precipitation annually) to juniper woodlands (20 cm precipitation) at the interior, dry end of the transect. The delta(13)C values of ecosystem respiration along this transect differed by only 1.3 per thousand (range of -25.2 to -23.9 per thousand ) during August at the peak of the summer drought. Following autumn rains in September, the delta(13)C of ecosystem respiration in the four stands decreased; overall the difference in the carbon isotope ratio of ecosystem respiration among sites increased to 3.9 per thousand (-26.8 to -22.9 per thousand ).

  3. Long-term greenhouse gas measurements from aircraft

    NASA Astrophysics Data System (ADS)

    Karion, A.; Sweeney, C.; Wolter, S.; Newberger, T.; Chen, H.; Andrews, A.; Kofler, J.; Neff, D.; Tans, P.

    2013-03-01

    In March 2009 the NOAA/ESRL/GMD Carbon Cycle and Greenhouse Gases Group collaborated with the US Coast Guard (USCG) to establish the Alaska Coast Guard (ACG) sampling site, a unique addition to NOAA's atmospheric monitoring network. This collaboration takes advantage of USCG bi-weekly Arctic Domain Awareness (ADA) flights, conducted with Hercules C-130 aircraft from March to November each year. Flights typically last 8 h and cover a large area, traveling from Kodiak up to Barrow, Alaska, with altitude profiles near the coast and in the interior. NOAA instrumentation on each flight includes a flask sampling system, a continuous cavity ring-down spectroscopy (CRDS) carbon dioxide (CO2)/methane (CH4)/carbon monoxide (CO)/water vapor (H2O) analyzer, a continuous ozone analyzer, and an ambient temperature and humidity sensor. Air samples collected in flight are analyzed at NOAA/ESRL for the major greenhouse gases and a variety of halocarbons and hydrocarbons that influence climate, stratospheric ozone, and air quality. We describe the overall system for making accurate greenhouse gas measurements using a CRDS analyzer on an aircraft with minimal operator interaction and present an assessment of analyzer performance over a three-year period. Overall analytical uncertainty of CRDS measurements in 2011 is estimated to be 0.15 ppm, 1.4 ppb, and 5 ppb for CO2, CH4, and CO, respectively, considering short-term precision, calibration uncertainties, and water vapor correction uncertainty. The stability of the CRDS analyzer over a seven-month deployment period is better than 0.15 ppm, 2 ppb, and 4 ppb for CO2, CH4, and CO, respectively, based on differences of on-board reference tank measurements from a laboratory calibration performed prior to deployment. This stability is not affected by variation in pressure or temperature during flight. We conclude that the uncertainty reported for our measurements would not be significantly affected if the measurements were made without in-flight calibrations, provided ground calibrations and testing were performed regularly. Comparisons between in situ CRDS measurements and flask measurements are consistent with expected measurement uncertainties for CH4 and CO, but differences are larger than expected for CO2. Biases and standard deviations of comparisons with flask samples suggest that atmospheric variability, flask-to-flask variability, and possible flask sampling biases may be driving the observed flask versus in situ CO2 differences rather than the CRDS measurements.

  4. Hydrogen isotope correction for laser instrument measurement bias at low water vapor concentration using conventional isotope analyses: application to measurements from Mauna Loa Observatory, Hawaii.

    PubMed

    Johnson, L R; Sharp, Z D; Galewsky, J; Strong, M; Van Pelt, A D; Dong, F; Noone, D

    2011-03-15

    The hydrogen and oxygen isotope ratios of water vapor can be measured with commercially available laser spectroscopy analyzers in real time. Operation of the laser systems in relatively dry air is difficult because measurements are non-linear as a function of humidity at low water concentrations. Here we use field-based sampling coupled with traditional mass spectrometry techniques for assessing linearity and calibrating laser spectroscopy systems at low water vapor concentrations. Air samples are collected in an evacuated 2 L glass flask and the water is separated from the non-condensable gases cryogenically. Approximately 2 µL of water are reduced to H(2) gas and measured on an isotope ratio mass spectrometer. In a field experiment at the Mauna Loa Observatory (MLO), we ran Picarro and Los Gatos Research (LGR) laser analyzers for a period of 25 days in addition to periodic sample collection in evacuated flasks. When the two laser systems are corrected to the flask data, they are strongly coincident over the entire 25 days. The δ(2)H values were found to change by over 200‰ over 2.5 min as the boundary layer elevation changed relative to MLO. The δ(2)H values ranged from -106 to -332‰, and the δ(18)O values (uncorrected) ranged from -12 to -50‰. Raw data from laser analyzers in environments with low water vapor concentrations can be normalized to the international V-SMOW scale by calibration to the flask data measured conventionally. Bias correction is especially critical for the accurate determination of deuterium excess in dry air. Copyright © 2011 John Wiley & Sons, Ltd.

  5. Automated simultaneous measurement of the δ(13) C and δ(2) H values of methane and the δ(13) C and δ(18) O values of carbon dioxide in flask air samples using a new multi cryo-trap/gas chromatography/isotope ratio mass spectrometry system.

    PubMed

    Brand, Willi A; Rothe, Michael; Sperlich, Peter; Strube, Martin; Wendeberg, Magnus

    2016-07-15

    The isotopic composition of greenhouse gases helps to constrain global budgets and to study sink and source processes. We present a new system for high-precision stable isotope measurements of carbon, hydrogen and oxygen in atmospheric methane and carbon dioxide. The design is intended for analyzing flask air samples from existing sampling programs without the need for extra sample air for methane analysis. CO2 and CH4 isotopes are measured simultaneously using two isotope ratio mass spectrometers, one for the analysis of δ(13) C and δ(18) O values and the second one for δ(2) H values. The inlet carousel delivers air from 16 sample positions (glass flasks 1-5 L and high-pressure cylinders). Three 10-port valves take aliquots from the sample stream. CH4 from 100-mL air aliquots is preconcentrated in 0.8-mL sample loops using a new cryo-trap system. A precisely calibrated working reference air is used in parallel with the sample according to the Principle of Identical Treatment. It takes about 36 hours for a fully calibrated analysis of a complete carousel including extractions of four working reference and one quality control reference air. Long-term precision values, as obtained from the quality control reference gas since 2012, account for 0.04 ‰ (δ(13) C values of CO2 ), 0.07 ‰ (δ(18) O values of CO2 ), 0.11 ‰ (δ(13) C values of CH4 ) and 1.0 ‰ (δ(2) H values of CH4 ). Within a single day, the system exhibits a typical methane δ(13) C standard deviation (1σ) of 0.06 ‰ for 10 repeated measurements. The system has been in routine operation at the MPI-BGC since 2012. Consistency of the data and compatibility with results from other laboratories at a high precision level are of utmost importance. A high sample throughput and reliability of operation are important achievements of the presented system to cope with the large number of air samples to be analyzed. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  6. Atmospheric CO2 From Flask Air Samples at 10 Sites in the Scripps Institution of Oceanography (SIO) Air Sampling Network (1957 - 2001) (issued 2004)

    DOE Data Explorer

    Keeling, Charles D. [Univ. of California, San Diego, CA (United States). Scripps Inst. of Oceanography; Whorf, Timothy P. [Univ. of California, San Diego, CA (United States). Scripps Inst. of Oceanography; Blasing, T. J. [Carbon Dioxide Information Analysis Center (CDIAC), Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (USA); Jones, Sonja [Carbon Dioxide Information Analysis Center (CDIAC), Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (USA)

    2004-09-01

    The Carbon Dioxide Research Group, Scripps Institution of Oceanography, University of California, San Diego, has provided this data set, which includes long-term measurements of near-surface atmospheric CO2 concentrations at 10 locations spanning latitudes 82°N to 90°S. Most of the data are based on replicated (collected at the same time and place) flask samples taken at intervals of approximately one week to one month and subsequently subjected to infrared analysis. Periods of record begin in various years, ranging from 1957 (for the South Pole station) to 1985 (for Alert, Canada), and all flask data records except for Christmas Island and Baring Head, New Zealand extend through year 2001. Christmas Island data end with August, 2001 and Baring Head data end with October 2001. Weekly averages of continuous data from Mauna Loa Observatory, Hawaii, are available back to March 1958. Similar weekly averages are also available for La Jolla, California, from November 1972 to October 1975, and for the South Pole from June 1960 to October 1963. These long-term records of atmospheric CO2 concentration complement the continuous records made by SIO, and also complement the long term flask records of the Climate Monitoring and Diagnostics Laboratory of the National Oceanic and Atmospheric Administration. All these data are useful for characterizing seasonal and geographical variations in atmospheric CO2 over several years, and for assessing results of global carbon models.

  7. Onboard measurement system of atmospheric carbon monoxide over the Pacific Ocean by voluntary observing ships

    NASA Astrophysics Data System (ADS)

    Nara, H.; Tanimoto, H.; Nojiri, Y.; Mukai, H.; Machida, T.; Tohjima, Y.

    2011-07-01

    Long-term monitoring of carbon monoxide (CO) mixing ratios in the atmosphere over the Pacific Ocean is being carried out on commercial cargo vessels participating in the National Institute for Environmental Studies Voluntary Observing Ships program. The program provides a regular platform for measurement of atmospheric CO along four cruising routes: from Japan to Oceania, from Japan to the United States, from Japan to Canada, and from Japan to Southeast Asia. Flask samples are collected during every cruise for subsequent analysis in the laboratory, and in 2005, continuous shipboard CO measurements were initiated on three of the routes. Here, we describe the system we developed for onboard measurement of CO mixing ratios with a commercially available gas filter correlation CO analyzer. The fully automated system measures CO in ambient air, and the detector sensitivity and background signals are calibrated by referencing the measurements to a CO-in-air standard gas (~1 ppmv) and to CO-free air scrubbed with a catalyst, respectively. We examined the artificial production of CO in the high-pressure working gas standards (CO balanced with purified air at ppmv levels) during storage by referencing the measurements to CO standard gases maintained as our primary scale before and after use on the ships. The onboard performance of the continuous CO measurement system was evaluated by comparing its data with data from laboratory analyses of flask samples using gas chromatography with a reduction gas detector. The reasonably good consistency between the two independent measurement methods demonstrated the good performance of both methods over the course of 3-5 yr. The continuous measurement system was more useful than the flask sampling method for regionally polluted air masses, which were often encountered on Southeast Asian cruises.

  8. Establishing Regular Measurements of Halocarbons at Taunus Observatory

    NASA Astrophysics Data System (ADS)

    Schuck, Tanja; Lefrancois, Fides; Gallmann, Franziska; Engel, Andreas

    2017-04-01

    In late 2013 an ongoing whole air flask collection program has been started at the Taunus Observatory (TO) in central Germany. Being a rural site in close vicinity to the densely populated Rhein-Main area with the city of Frankfurt, Taunus Observatory allows to assess local and regional emissions but owed to its altitude of 825m also regularly experiences background conditions. With its large caption area halocarbon measurements at the site have the potential to improve the data base for estimation of regional and total European halogenated greenhouse gas emissions. At current, flask samples are collected weekly for analysis using a GC-MS system at Frankfurt University employing a quadrupole as well as a time-of-flight (TOF) mass spectrometer. The TOF instrument yields full scan mass information and allows for retrospective analysis of so far undetected non-target species. For quality assurance additional samples are collected approximately bi-weekly at the Mace Head Atmospheric Research Station (MHD) analyzed in Frankfurt following the same measurement procedure. Thus the TO time series can be linked to both, the in-situ AGAGE measurements and the NOAA flask sampling program at MHD. In 2017 it is planned to supplement the current flask sampling by employing an in-situ GC-MS system at the site, thus increasing the measurement frequency. We will present the timeseries of selected halocarbons recorded at Taunus Observatory. While there is good agreement of baseline mixing ratios between TO and MHD, measurements at TO are regularly influenced by elevated halocarbon mixing ratios. An analysis of HYSPLIT trajectories for the existing time series revealed significant differences in halocarbon mixing ranges depending on air mass origin.

  9. Onboard measurement system of atmospheric carbon monoxide in the Pacific by voluntary observing ships

    NASA Astrophysics Data System (ADS)

    Nara, H.; Tanimoto, H.; Nojiri, Y.; Mukai, H.; Machida, T.; Tohjima, Y.

    2011-11-01

    Long-term monitoring of carbon monoxide (CO) mixing ratios in the atmosphere over the Pacific Ocean is being carried out on commercial cargo vessels participating in the National Institute for Environmental Studies Voluntary Observing Ships program. The program provides a regular platform for measurement of atmospheric CO along four cruise routes: from Japan to Oceania, the United States, Canada, and Southeast Asia. Flask samples are collected during every cruise for subsequent analysis in the laboratory, and in 2005, continuous shipboard CO measurements were initiated on three of the routes. Here, we describe the system we developed for onboard measurement of CO mixing ratios with a commercially available gas filter correlation CO analyzer. The fully automated system measures CO in ambient air, and the detector sensitivity and background signals are calibrated by referencing the measurements to a CO-in-air standard gas (~1 ppmv) and to CO-free air scrubbed with a catalyst, respectively. We examined the artificial production of CO in the high-pressure working gas standards during storage by referencing the measurements to CO standard gases maintained as our primary scale before and after use on the ships. The onboard performance of the continuous CO measurement system was evaluated by comparing its data with data from laboratory analyses of flask samples using gas chromatography with a reduction gas detector. The reasonably good consistency between the two independent measurement methods demonstrated the good performance of both methods over the course of 3-5 years. The continuous measurement system was more useful than the flask sampling method for regionally polluted air masses, which were often encountered on Southeast Asian cruises.

  10. Isotope and methane dynamics above and below the Trade Wind Inversion at Ascension Island using UAVs

    NASA Astrophysics Data System (ADS)

    Brownlow, R.; Lowry, D.; Nisbet, E. G.; Fisher, R. E.; France, J.; Lanoisellé, M.; Thomas, R.; Richardson, T.; Greatwood, C.; Freer, J. E.; MacKenzie, A. R.

    2015-12-01

    Ascension Island (8oS, 14 oW) is a South Atlantic background site for atmospheric measurement. Royal Holloway, in collaboration with the UK Met Office, installed a Picarro 1301 CRDS in 2010 for continuous methane monitoring. This has high precision and accuracy, with a 6-gas calibration and target suite, to measure long term methane mole fraction. Regular flask sampling is also carried out for NOAA and RHUL (co-located), to measure δ13CCH4 isotopic trends.Ascension Island experiences near-constant SE Trade winds below the Trade Wind Inversion (TWI), with air from the remote S. Atlantic. In flask samples and in continuous monitoring at the Airhead location, atmospheric methane mole fraction has been increasing since 2007 whilst the δ13CCH4 isotope record has shifted to more depleted values. Above the normally well-defined TWI (1200 - 1800m altitude), variable tropical air masses pass over Ascension. This air last mixed with the boundary layer over Africa or South America. Field work undertaken in September 2014 and July 2015, in collaboration with U. Bristol and U. Birmingham, using UAVs (octocopters) collected samples with Tedlar bags or aluminium flasks from different heights above and below the TWI. The maximum altitude reached was 2700masl. Sample bags were immediately analysed on Ascension for CH4 mole fraction using the Picarro CRDS and subsequently analysed at RHUL for δ13CCH4 using continuous-flow gas chromatography/isotope-ratio mass spectrometry (CF-GC/IRMS). The TWI was clearly identified by an increase in CH4 mole fraction above the TWI. Back trajectory analysis was used to distinguish the origins of the air masses, with air above showing inputs from the land surfaces of equatorial and southern Africa, and from southern S. America.The campaigns have extended the envelope of altitudes accessed by micro-UAVs for atmospheric science, demonstrating their utility for probing the remote free troposphere and for penetrating the TWI. Sampling at Ascension is able to measure both the deep S. Atlantic air and also the air that has been mixed by convective systems in the equatorial and southern savannah tropics. Biomass burning plumes in southern hemisphere winter may also be accessible. Ascension is thus potentially a measurement site of global significance.

  11. Atmospheric CO2 Concentrations--The Canadian Background Air Pollution Monitoring Network (1993) (NDP-034)

    DOE Data Explorer

    Trivett, N. B. A. [Environment Canada, Atmospheric Environment Service, Downsview, Ontario, Canada; Hudec, V. C. [Environment Canada, Atmospheric Environment Service, Downsview, Ontario, Canada; Wong, C. S. [Marine Carbon Research Centre, Institute of Ocean Sciences, Sidney, British Columbia, Canada

    1993-01-01

    Flask air samples collected at roughly weekly intervals at three Canadian sites [Alert, Northwest Territories (July 1975 through July 1992); Sable Island, Nova Scotia (March 1975 through July 1992); and Cape St. James, British Columbia (May 1979 through July 1992)] were analyzed for CO2 concentration with the measurements directly traceable to the WMO primary CO2 standards. Each record includes the date, atmospheric CO2 concentration, and flask classification code. They provide an accurate record of CO2 concentration levels in Canada during the past two decades. Because these data are directly traceable to WMO standards, this record may be compared with records from other Background Air Pollution Monitoring Network (BAPMoN) stations. The data are in three files (one for each of the monitoring stations) ranging in size from 9.4 to 20.1 kB.

  12. Optimizing laboratory-based radon flux measurements for sediments.

    PubMed

    Chanyotha, Supitcha; Kranrod, Chutima; Kritsananuwat, Rawiwan; Lane-Smith, Derek; Burnett, William C

    2016-07-01

    Radon flux via diffusion from sediments and other materials may be determined in the laboratory by circulating air through the sample and a radon detector in a closed loop. However, this approach is complicated by the necessity of having to determine the total air volume in the system and accounting for any small air leaks that can arise if using extended measurement periods. We designed a simple open-loop configuration that includes a measured mass of wet sediment and water inside a gas-tight reaction flask connected to a drying system and a radon-in-air analyzer. Ambient air flows through two charcoal columns before entering the reaction vessel to eliminate incoming radon. After traveling through the reaction flask, the air passes the drier and the radon analyzer and is then vented. After some time, the radon activity will reach a steady state depending upon the airflow rate. With this approach, the radon flux via diffusion is simply the product of the steady-state radon activity (Bq/m(3)) multiplied by the airflow rate (mL/min). We demonstrated that this setup could produce good results for materials that produce relatively high radon fluxes. We also show that a modified closed system approach, including radon removal of the incoming air by charcoal filtration in a bypass, can produce very good results including samples with very low emission rates. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Method for measuring changes in the atmospheric O2/N2 ratio by a gas chromatograph equipped with a thermal conductivity detector

    NASA Astrophysics Data System (ADS)

    Tohjima, Yasunori

    2000-06-01

    We present a method for measuring changes in the atmospheric O2/N2 ratio based on data from a gas chromatograph (GC) equipped with a thermal conductivity detector (TCD). In this method, O2 and N2 in an air sample are separated on a column filled with molecular sieve 5A with H2 carrier gas. Since the separated O2 includes Ar, which has a retention time similar to that of O2, the (O2+Ar)/N2 ratio is actually measured. The change in the measured (O2+Ar)/N2 ratio can be easily converted to that in the O2/N2 ratio with a very small error based on the fact that the atmospheric Ar/N2 ratio is almost constant. The improvements to achieve the high-precision measurement include stabilization of the pressure at the GC column head and at the outlets of the TCD and the sample loop. Additionally, the precision is improved statistically by repeating alternate analyses of sample and a reference gas. The standard deviation of the replicate cycles of reference and sample analyses is about 18 per meg (corresponding to 3.8 parts per million (ppm) O2 in air). This means that the standard error is about 7 per meg (1.5 ppm O2 in air) for seven cycles of alternate analyses, which takes about 70 min. The response of this method is likely to have a 2% nonlinearity. Ambient air samples are collected under pressure in glass flasks equipped with two stopcocks sealed by Viton O-rings at both ends. Pressure depletion in the flask during the O2/N2 measurement does not cause any detectable change in the O2/N2 ratio, but the O2/N2 ratio in the flask was found to gradually decrease during the storage period. We also present preliminary results from air samples collected at Hateruma Island (latitude 24°03'N, longitude 123°49') from July 1997 through March 1999. The observed O2/N2 ratios clearly show a seasonal variation, increasing in spring and summer and decreasing in autumn and winter.

  14. Atmospheric CO2 Records from Sites in the Main Geophysical Observatory Air Sampling Network (1983 - 1993)

    DOE Data Explorer

    Brounshtein, A. M. [Main Geophysical Observatory, St. Petersburg, Russia; Shaskov, A. A. [Main Geophysical Observatory, St. Petersburg, Russia; Paramonova, N. N. [Main Geophysical Observatory, St. Petersburg, Russia; Privalov, V. I. [Main Geophysical Observatory, St. Petersburg, Russia; Starodubtsev, Y. A. [Main Geophysical Observatory, St. Petersburg, Russia

    1997-01-01

    Air samples were collected from five sites in the Main Geophysical Observatory air sampling network to monitor the atmospheric CO2 from 1983 - 1993. Airwas collected generally four times per month in pairs of 1.5-L stainless steel electropolished flasks with one greaseless stainless steel stopcock. Sampling was performed by opening the stopcock of the flasks, which have been evacuated at the central laboratory at the Main Geophysical Observatory (MGO). The air was not dried during sample collection. Attempts were made to obtain samples when the wind speed was >5 m/s and the wind direction corresponded to the predetermined "clean air" sector. The period of record at Bering Island is too short to identify any long-term trends in atmospheric CO2 concentrations; however, the yearly mean atmospheric CO2 concentration at Bering Island rose from approximately 346 parts per million by volume (ppmv) in 1986 to 362.6 ppmv in 1993. Measurements from this station are considered indicative of maritime air masses. The period of record at Kotelny Island is too short to identify any long-term trends in atmospheric CO2 concentrations; however, the yearly mean atmospheric CO2 concentration at Kotelny Island rose from 356.08 parts per million by volume (ppmv) in 1988 to 358.8 ppmv in 1993. Because Kotelny Island is the northernmost Russian sampling site, measurements from this site serve as a useful comparison to other northern sites (e.g., Alert, Northwest Territories). In late 1989, air sampling began at the Russian site of Kyzylcha, located in the Republic of Uzbekistan. Unfortunately, the desert site at Kyzylcha has been out of operation since mid-1991 due to financial difficulties in Russia. The annual mean value of 359.02 parts per million by volume (ppmv) for 1990, the lone full year of operation, is higher than measurements from other monitoring programs at this latitude [e.g., Niwot Ridge (354.7 ppmv in 1990) and Tae-ahn Peninsula]. Station "C," an open ocean site, in the North Atlantic, east of Greenland, was established in 1968 and was operated in cooperation with NOAA's National Weather Service through 1973. The Main Geophysical Observatory collected flask samples at the site from January 1983 through October 1990. The yearly mean atmospheric CO concentration at Station "C" rose from 348.15 parts per million by volume (ppmv) in 1985 to 354.33 ppmv in 1989. The period of record at Teriberka Station is too short to identify any long-term trends in atmospheric CO2 concentrations; however, the yearly mean atmospheric CO2 concentration at Teriberka Station rose from 354.8 parts per million by volume (ppmv) in 1989 to 358.7 ppmv in 1993.

  15. AN EQUATORIAL PACIFIC RAIN EVENT: INFLUENCE ON THE DISTRIBUTION OF IRON AND HYDROGEN PEROXIDE IN SURFACE WATERS

    EPA Science Inventory

    Methods are described for measuring changes in atmospheric O2 concentration with emphasis on gas handling procedures. Cryogenically dried air samples are collected in 5 L glass flasks at ambient pressure and analyzed against reference gases derived from high-pressure aluminum tan...

  16. Some Interesting Thermodynamics of the Thermos Flask

    ERIC Educational Resources Information Center

    Berger, Roland

    2007-01-01

    When opening a thermos flask filled with coffee, one often "hears" the equalization of the pressure difference that appears to be present between the air cavity inside the flask and the surrounding room atmosphere. Recently we discussed this phenomenon while drinking coffee and guessed about the direction of the gas stream accompanying the…

  17. Globally Averaged Atmospheric CFC-11 Concentrations: Monthly and Annual Data for the Period 1975-1992 (DB1010)

    DOE Data Explorer

    Khalil, M. A.K. [Oregon Graduate Institute of Science and Technology Portland, Oregon (USA); Rasmussen, R. A. [Oregon Graduate Institute of Science and Technology Portland, Oregon

    1996-01-01

    This data set presents globally averaged atmospheric concentrations of chlorofluorocarbon 11, known also as CFC-11 or F-11 (chemical name: trichlorofluoromethane; formula: CCl3F). The monthly global average data are derived from flask air samples collected at eight sites in six locations over the period August 1980-July 1992. The sites are Barrow (Alaska), Cape Meares (Oregon), Cape Kumukahi and Mauna Loa (Hawaii), Cape Matatula (American Samoa), Cape Grim (Tasmania), Palmer Station, and the South Pole (Antarctica). At each collection site, monthly averages were obtained from three flask samples collected every week. In addition to the monthly global averages available for 1980-992, this data set also contains annual global average data for 1975-1985. These annual global averages were derived from January measurements at the South Pole and in the Pacific Northwest of the United States (specifically, Washington state and the Oregon coast).

  18. Observations of Gas Emissions from Cascade Range Volcanoes (USA) using a Portable Real-Time Sensor Package and Evacuated Flasks

    NASA Astrophysics Data System (ADS)

    Kelly, P. J.; Werner, C. A.; Evans, W.; Ingebritsen, S.; Tucker, D.

    2012-12-01

    Degassing from most Cascade Range Volcanoes, USA, is characterized by low-temperature hydrothermal emissions. It is important to monitor these emissions as part of a comprehensive monitoring strategy yet access is often difficult and most features are sampled by the USGS only once per year at best. In an effort to increase the sampling frequency of major gas species and in preparation for building permanent, autonomous units, we built a portable sensor package capable of measuring H2O, CO2, SO2, and H2S in volcanic gas plumes. Here we compare results from the portable sensor package with gas analyses from direct samples obtained using a titanium tube and evacuated glass flasks collected at the same time. The sensor package is housed in a small, rugged case, weighs 5 kg, and includes sensors for measuring H2O (0-16 parts per thousand), CO2 (0-5000 ppmv), SO2 (0-100 ppm), and H2S (0-20 ppm) gases. Additional temperature and pressure sensors, a micro air pump, datalogger, and an internal battery are also incorporated. H2O and CO2 are measured using an infrared spectrometer (Licor 840) and sulfur-containing gases are measured using electrochemical sensors equipped with filters to mitigate cross-sensitivities. Data are collected at a 1 Hz sampling rate and can be recorded and displayed in real-time using a netbook computer or can be saved to the onboard datalogger. The data display includes timeseries of H2O, CO2, SO2, and H2S mixing ratios, the four-component bulk composition of the plume, and automated calculation of gas ratios commonly used in volcanic gas monitoring, such as H2O/CO2, CO2/SO2, and CO2/H2S . In the Cascade Range, the sensor package has been tested at Mt. Baker, Mt. St. Helens, Mt. Hood, and in Lassen Volcanic National Park. In each case, the instrument was placed 5 to 30 meters from the fumarole or fumarole field and emissions were sampled for 5 to 30 minutes. No SO2 was detected at any location. At Mt. Hood the sensor package yielded average CO2/H2S ratios from 10 to 16 in fumarole plumes versus flask CO2/H2S ratios (n = 2) of 13 and 16 on 9 July 2011, and on 28 July 2012 the sensor package yielded an average CO2/H2S ratio of 12 versus flask ratios (n = 2) of 13 (both sets of flask samples obtained in the Crater Rock area). At Mt. Baker, the sensor package yielded average CO2/H2S ratios from 19 to 22 whereas flask ratios (n = 3) were higher, from 25 to 32 (both fumarole-plume and flask samples obtained in the Sherman Crater area) on 22 July 2011. The mismatch falls slightly outside expected analytical uncertainty for the sensor package (about 20% relative for CO2/H2S ratios). However, flask samples collected in Sherman Crater in 2006 and 2007 (n = 5) yielded CO2/H2S ratios from 18 to 29, which nearly spans the range of observations in 2011. Therefore, one explanation for the small mismatch between the results of the sensor package and direct samples is that the sensor package measures bulk plume compositions that may integrate emissions from several chemically distinct fumaroles and the direct samples better represent the composition of discrete vents. Overall, the sensor package and evacuated flask data show good agreement and demonstrate that the real-time technique is a viable means for monitoring major volcanic gas species.

  19. The Safe and Efficient Evaporation of a Solvent from Solution

    NASA Astrophysics Data System (ADS)

    Mahon, Andrew R.

    1997-02-01

    The process of evaporating a solvent from a solution can cause problems for many students. By using a water-vacuum aspirator, backflashes of water can flood the sample tube and be detrimental to the experiment. This type of apparatus can also cause problems by drawing the solution it is evaporating back into the vacuum hose, causing the student to lose part or all of the products of their experiment. Macroscale and Microscale Organic Experiments, 2nd edition (1), suggested two techniques to dissolve solvents from a mixture. It suggested blowing a stream of air over the solution from a Pasteur pipet, or attaching a Pasteur pipet to an aspirator and drawing air over the surface of the liquid. Again, the danger of blowing air over the solution leaves the risk of splattering the solution, and drawing air over the surface of the liquid as described further endangers the products of the experiment through the risk of sucking the products up into the pipet aspirator. In an effort to eliminate these problems, a new technique has been developed. By inverting an ordinary 200-mL vacuum flask and pulling a steady current of air from the vacuum apparatus through it, any type of small container can be placed under it, allowing the solvent to be evaporated in a steady, mistake-free manner . By evaporating the solvent from the container that the products will be submitted in, no sample is lost through the process of transferring it from a vacuum flask or beaker to the final container.

  20. High-precision quasi-continuous atmospheric greenhouse gas measurements at Trainou tower (Orléans forest, France)

    NASA Astrophysics Data System (ADS)

    Schmidt, M.; Lopez, M.; Yver Kwok, C.; Messager, C.; Ramonet, M.; Wastine, B.; Vuillemin, C.; Truong, F.; Gal, B.; Parmentier, E.; Cloué, O.; Ciais, P.

    2014-07-01

    Results from the Trainou tall tower measurement station installed in 2006 are presented for atmospheric measurements of CO2, CH4, N2O, SF6, CO, H2 mole fractions and radon-222 activity. Air is sampled from four sampling heights (180, 100, 50 and 5 m) of the Trainou 200 m television tower in the Orléans forest in France (47°57'53" N, 2°06'45" E, 131 m a.s.l.). The station is equipped with a custom-built CO2 analyser (CARIBOU), which is based on a commercial non-dispersive, infrared (NDIR) analyser (Licor 6252), and a coupled gas chromatography (GC) system equipped with an electron capture detector (ECD) and a flame ionization detector (FID) (HP6890N, Agilent) and a reduction gas detector (PP1, Peak Performer). Air intakes, pumping and air drying system are shared between the CARIBOU and the GC systems. The ultimately achieved short-term repeatability (1 sigma, over several days) for the GC system is 0.05 ppm for CO2, 1.4 ppb for CH4, 0.25 ppb for N2O, 0.08 ppb for SF6, 0.88 ppb for CO and 3.8 for H2. The repeatability of the CARIBOU CO2 analyser is 0.06 ppm. In addition to the in situ measurements, weekly flask sampling is performed, and flask air samples are analysed at the Laboratoire des Sciences du Climat et de l'Environnement (LSCE) central laboratory for the same species as well for stable isotopes of CO2. The comparison between in situ measurements and the flask sampling showed averaged differences of 0.08 ± 1.40 ppm for CO2, 0.7 ± 7.3 ppb for CH4, 0.6 ± 0.6 ppb for N2O, 0.01 ± 0.10 ppt for SF6, 1.5± 5.3 ppb for CO and 4.8± 6.9 ppb for H2 for the years 2008-2012. At Trainou station, the mean annual increase rates from 2007 to 2011 at the 180 m sampling height were 2.2 ppm yr-1 for CO2, 4 ppb yr-1 for CH4, 0.78 ppb yr-1 for N2O and 0.29 ppt yr-1 for SF6. For all species, the 180 m sampling level showed the smallest diurnal variation. Mean diurnal gradients between the 50 m and the 180 m sampling level reached up to 30 ppm CO2, 15 ppm CH4 or 0.5 ppb N2O during nighttime whereas the mean gradients are smaller than 0.5 ppm for CO2 and 1.5 ppb for CH4 during afternoon.

  1. Fabrication of prototype for measuring the exhaled breath temperature (EBT) to support detection of asthma

    NASA Astrophysics Data System (ADS)

    Harnawan, A. A.; Mariati; Fahrudin, A.; Assegaf, A.

    2017-05-01

    Recently, EBT has been proven as the marker of airways inflammation like asthma and proposed as the non-invasive tool. Although EBT device has already been made but this device is rarely used for patients in Indonesia. The aim of this study is to develop a prototype which accurately measures EBT and is comfortably used by patients including children. This prototype was made using SHT11 as a sensor of EBT which is integrated on a thermal flask 0.5L. This flask filled up patient breath and the temperature of air breath was measured. The EBT of twelve healthy samples and seven samples with asthma was examined using this prototype, the measurement was done within three minutes for all of them. The test results of EBT on healthy samples obtained the median is 33.9°C within of 33.0°C - 34.7°C and EBT on asthma samples obtained median is 35.0°C within the range 34.9°C - 36.0°C.

  2. Optimized measurement of radium-226 concentration in liquid samples with radon-222 emanation.

    PubMed

    Perrier, Frédéric; Aupiais, Jean; Girault, Frédéric; Przylibski, Tadeusz A; Bouquerel, Hélène

    2016-06-01

    Measuring radium-226 concentration in liquid samples using radon-222 emanation remains competitive with techniques such as liquid scintillation, alpha or mass spectrometry. Indeed, we show that high-precision can be obtained without air circulation, using an optimal air to liquid volume ratio and moderate heating. Cost-effective and efficient measurement of radon concentration is achieved by scintillation flasks and sufficiently long counting times for signal and background. More than 400 such measurements were performed, including 39 dilution experiments, a successful blind measurement of six reference test solutions, and more than 110 repeated measurements. Under optimal conditions, uncertainties reach 5% for an activity concentration of 100 mBq L(-1) and 10% for 10 mBq L(-1). While the theoretical detection limit predicted by Monte Carlo simulation is around 3 mBq L(-1), a conservative experimental estimate is rather 5 mBq L(-1), corresponding to 0.14 fg g(-1). The method was applied to 47 natural waters, 51 commercial waters, and 17 wine samples, illustrating that it could be an option for liquids that cannot be easily measured by other methods. Counting of scintillation flasks can be done in remote locations in absence of electricity supply, using a solar panel. Thus, this portable method, which has demonstrated sufficient accuracy for numerous natural liquids, could be useful in geological and environmental problems, with the additional benefit that it can be applied in isolated locations and in circumstances when samples cannot be transported. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. A simple bubbling system for measuring radon (222Rn) gas concentrations in water samples based on the high solubility of radon in olive oil.

    PubMed

    Al-Azmi, D; Snopek, B; Sayed, A M; Domanski, T

    2004-01-01

    Based on the different levels of solubility of radon gas in organic solvents and water, a bubbling system has been developed to transfer radon gas, dissolving naturally in water samples, to an organic solvent, i.e. olive oil, which is known to be a good solvent of radon gas. The system features the application of a fixed volume of bubbling air by introducing a fixed volume of water into a flask mounted above the system, to displace an identical volume of air from an air cylinder. Thus a gravitational flow of water is provided without the need for pumping. Then, the flushing air (radon-enriched air) is directed through a vial containing olive oil, to achieve deposition of the radon gas by another bubbling process. Following this, the vial (containing olive oil) is measured by direct use of gamma ray spectrometry, without the need of any chemical or physical processing of the samples. Using a standard solution of 226Ra/222Rn, a lowest measurable concentration (LMC) of radon in water samples of 9.4 Bq L(-1) has been achieved (below the maximum contaminant level of 11 Bq L(-1)).

  4. Modeling of growth and laccase production by Pycnoporus sanguineus.

    PubMed

    Saat, Muhammad Naziz; Annuar, Mohamad Suffian Mohamad; Alias, Zazali; Chuan, Ling Tau; Chisti, Yusuf

    2014-05-01

    Production of extracellular laccase by the white-rot fungus Pycnoporus sanguineus was examined in batch submerged cultures in shake flasks, baffled shake flasks and a stirred tank bioreactor. The biomass growth in the various culture systems closely followed a logistic growth model. The production of laccase followed a Luedeking-Piret model. A modified Luedeking-Piret model incorporating logistic growth effectively described the consumption of glucose. Biomass productivity, enzyme productivity and substrate consumption were enhanced in baffled shake flasks relative to the cases for the conventional shake flasks. This was associated with improved oxygen transfer in the presence of the baffles. The best results were obtained in the stirred tank bioreactor. At 28 °C, pH 4.5, an agitation speed of 600 rpm and a dissolved oxygen concentration of ~25 % of air saturation, the laccase productivity in the bioreactor exceeded 19 U L(-1 )days(-1), or 1.5-fold better than the best case for the baffled shake flask. The final concentration of the enzyme was about 325 U L(-1).

  5. Ambient air/near-field measurements of methane and Volatile Organic Compounds (VOCs) from a natural gas facility in Northern Europe

    NASA Astrophysics Data System (ADS)

    Baudic, Alexia; Gros, Valérie; Bonsang, Bernard; Baisnee, Dominique; Vogel, Félix; Yver Kwok, Camille; Ars, Sébastien; Finlayson, Andrew; Innocenti, Fabrizio; Robinson, Rod

    2015-04-01

    Since the 1970's, the natural gas consumption saw a rapid growth in large urban centers, thus becoming an important energy resource to meet continuous needs of factories and inhabitants. Nevertheless, it can be a substantial source of methane (CH4) and pollutants in urban areas. For instance, we have determined that about 20% of Volatile Organic Compounds (VOCs) in downtown Paris are originating from this emission source (Baudic, Gros et al., in preparation). Within the framework of the "Fugitive Methane Emissions" (FuME) project (Climate-KIC, EIT); 2-weeks gas measurements were conducted at a gas compressor station in Northern Europe. Continuous ambient air measurements of methane and VOCs concentrations were performed using a cavity ring-down spectrometer (model G2201, Picarro Inc., Santa Clara, USA) and two portable GC-FID (Chromatotec, Saint-Antoine, France), respectively. On-site near-field samplings were also carried out at the source of two pipelines using stainless steel flasks (later analyzed with a laboratory GC-FID). The objective of this study aims to use VOCs as additional tracers in order to better characterize the fugitive methane emissions in a complex environment, which can be affected by several urban sources (road-traffic, others industries, etc.). Moreover, these measurements have allowed determining the chemical composition of this specific source. Our results revealed that the variability of methane and some VOCs was (rather) well correlated, especially for alkanes (ethane, propane, etc.). An analysis of selected events with strong concentrations enhancement was performed using ambient air measurements; thus allowing the preliminary identification of different emission sources. In addition, some flasks were also sampled in Paris to determine the local natural gas composition. A comparison between both was then performed. Preliminary results from these experiments will be presented here.

  6. Methods of Sensing Land Pollution from Sanitary Landfills

    NASA Technical Reports Server (NTRS)

    Nosanov, Myron Ellis; Bowerman, Frank R.

    1971-01-01

    Major cities are congested and large sites suitable for landfill development are limited. Methane and other gases are produced at most sanitary landfills and dumps. These gases may migrate horizontally and vertically and have caused fatalities. Monitoring these gases provides data bases for design and construction of safe buildings on and adjacent to landfills. Methods of monitoring include: (1) a portable combustible gas indicator; and (2) glass flasks valved to allow simultaneous exhaust of the flask and aspiration of the sample into the flask. Samples are drawn through tubing from probes as deep as twenty-five feet below the surface.

  7. Simplified Method of the Growth of Human Tumor Infiltrating Lymphocytes (TIL) in Gas-Permeable Flasks to Numbers Needed for Patient Treatment

    PubMed Central

    Jin, Jianjian; Sabatino, Marianna; Somerville, Robert; Wilson, John R.; Dudley, Mark E.; Stroncek, David F.; Rosenberg, Steven A.

    2012-01-01

    Adoptive cell therapy (ACT) of metastatic melanoma with autologous tumor infiltrating lymphocytes (TIL) is clinically effective, but TIL production can be challenging. Here we describe a simplified method for initial TIL culture and rapid expansion in gas-permeable flasks. TIL were initially cultured from tumor digests and fragments in 40 mL capacity flasks with a 10 cm2 gas-permeable silicone bottom, G-Rex10. A TIL rapid expansion protocol (REP) was developed using 500 mL capacity flasks with a 100 cm2 gas-permeable silicone bottom, G-Rex100. TIL growth was successfully initiated in G-Rex10 flasks from tumor digests from 13 of 14 patients and from tumor fragments in all 11 tumor samples tested. TIL could then be expanded to 8–10×109 cells in a two-step REP which began by seeding 5 × 106 TIL into a G-Rex100 flask, followed by expansion at day 7 into 3 G-Rex100 flasks. To obtain the 30 to 60 × 109 cells used for patient treatment we seeded 6 G-Rex100 flasks with 5×106 cells and expanded into 18 G-Rex100 flasks. Large scale TIL REP in gas-permeable flasks requires approximately 9 to 10 liters of media, about 3 to 4 times less than other methods. In conclusion, TIL initiation and REP in gas-permeable G-Rex flasks require fewer total vessels, less media, less incubator space and less labor than initiation and REP in 24-well plates, tissue culture flasks and bags. TIL culture in G-Rex flasks will facilitate the production of TIL at the numbers required for patient treatment at most cell processing laboratories. PMID:22421946

  8. A versatile, refrigerant- and cryogen-free cryofocusing-thermodesorption unit for preconcentration of traces gases in air

    NASA Astrophysics Data System (ADS)

    Obersteiner, Florian; Bönisch, Harald; Keber, Timo; O'Doherty, Simon; Engel, Andreas

    2016-10-01

    We present a compact and versatile cryofocusing-thermodesorption unit, which we developed for quantitative analysis of halogenated trace gases in ambient air. Possible applications include aircraft-based in situ measurements, in situ monitoring and laboratory operation for the analysis of flask samples. Analytes are trapped on adsorptive material cooled by a Stirling cooler to low temperatures (e.g. -80 °C) and subsequently desorbed by rapid heating of the adsorptive material (e.g. +200 °C). The set-up involves neither the exchange of adsorption tubes nor any further condensation or refocusing steps. No moving parts are used that would require vacuum insulation. This allows for a simple and robust design. Reliable operation is ensured by the Stirling cooler, which neither contains a liquid refrigerant nor requires refilling a cryogen. At the same time, it allows for significantly lower adsorption temperatures compared to commonly used Peltier elements. We use gas chromatography - mass spectrometry (GC-MS) for separation and detection of the preconcentrated analytes after splitless injection. A substance boiling point range of approximately -80 to +150 °C and a substance mixing ratio range of less than 1 ppt (pmol mol-1) to more than 500 ppt in preconcentrated sample volumes of 0.1 to 10 L of ambient air is covered, depending on the application and its analytical demands. We present the instrumental design of the preconcentration unit and demonstrate capabilities and performance through the examination of analyte breakthrough during adsorption, repeatability of desorption and analyte residues in blank tests. Examples of application are taken from the analysis of flask samples collected at Mace Head Atmospheric Research Station in Ireland using our laboratory GC-MS instruments and by data obtained during a research flight with our in situ aircraft instrument GhOST-MS (Gas chromatograph for the Observation of Tracers - coupled with a Mass Spectrometer).

  9. Real-time analysis of δ13C- and δD-CH4 in ambient air with laser spectroscopy: method development and first intercomparison results

    NASA Astrophysics Data System (ADS)

    Eyer, S.; Tuzson, B.; Popa, M. E.; van der Veen, C.; Röckmann, T.; Rothe, M.; Brand, W. A.; Fisher, R.; Lowry, D.; Nisbet, E. G.; Brennwald, M. S.; Harris, E.; Zellweger, C.; Emmenegger, L.; Fischer, H.; Mohn, J.

    2015-08-01

    In situ and simultaneous measurement of the three most abundant isotopologues of methane using mid-infrared laser absorption spectroscopy is demonstrated. A field-deployable, autonomous platform is realized by coupling a compact quantum cascade laser absorption spectrometer (QCLAS) to a preconcentration unit, called TRace gas EXtractor (TREX). This unit enhances CH4 mole fractions by a factor of up to 500 above ambient levels and quantitatively separates interfering trace gases such as N2O and CO2. The analytical precision of the QCLAS isotope measurement on the preconcentrated (750 ppm, parts-per-million, μmole/mole) methane is 0.1 and 0.5 ‰ for δ13C- and δD-CH4 at 10 min averaging time. Based on replicate measurements of compressed air during a two-week intercomparison campaign, the repeatability of the TREX-QCLAS was determined to be 0.19 and 1.9 ‰ for δ13C and δD-CH4, respectively. In this intercomparison campaign the new in situ technique is compared to isotope-ratio mass-spectrometry (IRMS) based on glass flask and bag sampling and real time CH4 isotope analysis by two commercially available laser spectrometers. Both laser-based analyzers were limited to methane mole fraction and δ13C-CH4 analysis, and only one of them, a cavity ring down spectrometer, was capable to deliver meaningful data for the isotopic composition. After correcting for scale offsets, the average difference between TREX-QCLAS data and bag/flask sampling-IRMS values are within the extended WMO compatibility goals of 0.2 and 5 ‰ for δ13C- and δD-CH4, respectively. Thus, the intercomparison also reveals the need for reference air samples with accurately determined isotopic composition of CH4 to further improve the interlaboratory compatibility.

  10. Recent Results From the NOAA/ESRL GMD Tall Tower Network

    NASA Astrophysics Data System (ADS)

    Andrews, A. E.; Tans, P. P.; Peters, W.; Hirsch, A.; Sweeney, C.; Petron, G.; Kofler, J.; Zhao, C.; Masarie, K.; Wofsy, S. C.; Matross, D. M.; Mahadevan, P.; Longo, M.; Gerbig, C.; Lin, J. C.

    2006-12-01

    We will present a summary of new results from NOAA Earth System Research Laboratory`s Tall Tower greenhouse gas monitoring network. The tower network is operated by the Global Monitoring Division, which also maintains the global Cooperative Air Sampling network and a network of aircraft profiling sites over North America. Tall tower CO2 mixing ratio measurements are sensitive to upwind fluxes over scales of hundreds of kilometers, and the primary objective of the tower network is to obtain regionally representative carbon flux estimates for the North American continent. Mixing ratios of CO2 and CO are measured semi-continuously at the towers, and the KWKT-TV tower site near Moody, TX has recently also been equipped with sensors to measure radon and O3. Daily flask samples are collected at the KWKT tower and analyzed for CO2, CO, CH4, SF6, N2O, H2, stable isotopes of CO2 and CH4, COS, and a variety of halocarbon and hydrocarbon species. Daily flask sampling will be implemented at all tower sites within the next few years. We have used the Stochastic Time Inverted Lagrangian Transport (STILT) model to investigate upwind influences on the tower observations. CO measurements provide an indicator of polluted air masses, and we will present a summary of the frequency and origin of pollution events observed at the towers. We will present an analysis of the primary factors contributing to observed CO2 variability along with average seasonal and diurnal cycles of CO2 at the tower sites. Tower measurements are being used to evaluate atmospheric transport models in the context of the Transcom Continuous experiment and are an important constraint for CO2 data assimilation systems that produce regional to global carbon flux estimates with up to weekly resolution.

  11. Wider-Opening Dewar Flasks for Cryogenic Storage

    NASA Technical Reports Server (NTRS)

    Ruemmele, Warren P.; Manry, John; Stafford, Kristin; Bue, Grant; Krejci, John; Evernden, Bent

    2010-01-01

    Dewar flasks have been proposed as containers for relatively long-term (25 days) storage of perishable scientific samples or other perishable objects at a temperature of 175 C. The refrigeration would be maintained through slow boiling of liquid nitrogen (LN2). For the purposes of the application for which these containers were proposed, (1) the neck openings of commercial off-the-shelf (COTS) Dewar flasks are too small for most NASA samples; (2) the round shapes of the COTS containers give rise to unacceptably low efficiency of packing in rectangular cargo compartments; and (3) the COTS containers include metal structures that are too thermally conductive, such that they cannot, without exceeding size and weight limits, hold enough LN2 for the required long-term-storage. In comparison with COTS Dewar flasks, the proposed containers would be rectangular, yet would satisfy the long-term storage requirement without exceeding size and weight limits; would have larger neck openings; and would have greater sample volumes, leading to a packing efficiency of about double the sample volume as a fraction of total volume. The proposed containers would be made partly of aerospace- type composite materials and would include vacuum walls, multilayer insulation, and aerogel insulation.

  12. Preliminary report on part of the Oat Hill quicksilver mine, Mayacmas district, Napa County, California

    USGS Publications Warehouse

    Fix, Philip Forsyth

    1955-01-01

    Oat Hill quicksilver mine, located in the Mayacmas district of northern California, and credited with having produced more than 160,000 flasks of quicksilver, was sampled cooperatively by the Buray of Mines and Geological Survey during 1944. 28 diamond drill holes totaling 8,120 feet were drilled by the Bureau of Mines in four of the six principal veins to sample virgin low-grade reserves and stope fill, and reserves in the other two veins were estimated from existing underground workings and by inferences from drill holes in nearby veins. The writer estimates a total of 10,220 flasks of quicksilver in indicated and inferred reserves totaling 320,000 tons. Indicated reserves minable under 1943 conditions are estimated at 1,960 flasks of quicksilver in 75,000 tons averaging 3.0 lbs Hg per ton. Inferred reserves minable under 1943 conditions are estimated at 4,640 flasks of quicksilver in 109,920 tons averaging about 3.2 lbs Hg per ton. Inferred reserves believed minable only under economic conditions much more favorable than even those of 1943 are estimated at 2,620 flasks of quicksilver in 135,080 tons averaging a little less than 1.5 lbs Hg per ton. About two-thirds of the indicated reserves are accessible in underground workings. All other reserves are estimated approximately without access underground. Several areas not sampled may possibly contain reserves.

  13. Practices of shake-flask culture and advances in monitoring CO2 and O2.

    PubMed

    Takahashi, Masato; Aoyagi, Hideki

    2018-05-01

    About 85 years have passed since the shaking culture was devised. Since then, various monitoring devices have been developed to measure culture parameters. O 2 consumed and CO 2 produced by the respiration of cells in shaking cultures are of paramount importance due to their presence in both the culture broth and headspace of shake flask. Monitoring in situ conditions during shake-flask culture is useful for analysing the behaviour of O 2 and CO 2 , which interact according to Henry's law, and is more convenient than conventional sampling that requires interruption of shaking. In situ monitoring devices for shake-flask cultures are classified as direct or the recently developed bypass type. It is important to understand the characteristics of each type along with their unintended effect on shake-flask cultures, in order to improve the existing devices and culture conditions. Technical developments in the bypass monitoring devices are strongly desired in the future. It is also necessary to understand the mechanism underlying conventional shake-flask culture. The existing shaking culture methodology can be expanded into next-generation shake-flask cultures constituting a novel culture environment through a judicious selection of monitoring devices depending on the intended purpose of shake-flask culture. Construction and sharing the databases compatible with the various types of the monitoring devices and measurement instruments adapted for shaking culture can provide a valuable resource for broadening the application of cells with shake-flask culture.

  14. An Assessment of the Ability of Potential Spaceborne Instruments to Resolve Spatial and Temporal Variability of Atmospheric Carbon Dioxide

    NASA Technical Reports Server (NTRS)

    Andrews, Arlyn E.; Kawa, S. Randolph

    2001-01-01

    Mounting concern regarding the possibility that increasing carbon dioxide concentrations will initiate climate change has stimulated interest in the feasibility of measuring CO2 mixing ratios from satellites. Currently, the most comprehensive set of atmospheric CO2 data is from the NOAA CMDL cooperative air sampling network, consisting of more than 40 sites where flasks of air are collected approximately weekly. Sporadic observations in the troposphere and stratosphere from airborne in situ and flask samplers are also available. Although the surface network is extensive, there is a dearth of data in the Southern Hemisphere and most of the stations were intentionally placed in remote areas, far from major sources. Sufficiently precise satellite observations with adequate spatial and temporal resolution would substantially increase our knowledge of the atmospheric CO2 distribution and would undoubtedly lead to improved understanding of the global carbon budget. We use a 3-D chemical transport model to investigate the ability of potential satellite instruments with a variety of orbits, horizontal resolution and vertical weighting functions to capture the variation in the modeled CO2 fields. The model is driven by analyzed winds from the Goddard Data Assimilation Office. Simulated CO2 fields are compared with existing surface and aircraft data, and the effects of the model convection scheme and representation of the planetary boundary layer are considered.

  15. An Assessment of the Ability of Potential Space-Borne Instruments to Resolve Spatial and Temporal Variability of Atmospheric Carbon Dioxide

    NASA Technical Reports Server (NTRS)

    Andrews, Arlyn E.; Kawa, S. Randolph; Einaudi, Franco (Technical Monitor)

    2001-01-01

    Mounting concern regarding the possibility that increasing carbon dioxide concentrations will initiate climate change has stimulated interest in the feasibility of measuring CO2 mixing ratios from satellites. Currently, the most comprehensive set of atmospheric CO2 data is from the NOAA CMDL cooperative air sampling network, consisting of more than 40 sites where flasks of air are collected approximately weekly. Sporadic observations in the troposphere and stratosphere from airborne in situ and flask samplers are also available. Although the surface network is extensive, there is a dearth of data in the Southern Hemisphere and most of the stations were intentionally placed in remote areas, far from major sources. Sufficiently precise satellite observations with adequate spatial and temporal resolution would substantially increase our knowledge of the atmospheric CO2 distribution and would undoubtedly lead to improved understanding of the global carbon budget. We use a 3-D chemical transport model to investigate the ability of potential satellite instruments with a variety of orbits, horizontal resolution and vertical weighting functions to capture the variation in the modeled CO2 fields. The model is driven by analyzed winds from the Goddard Data Assimilation Office. Simulated CO2 fields are compared with existing surface and aircraft data, and the effects of the model convection scheme and representation of the planetary boundary layer are considered.

  16. Deactivation of Cellulase at the Air-Liquid Interface Is the Main Cause of Incomplete Cellulose Conversion at Low Enzyme Loadings.

    PubMed

    Bhagia, Samarthya; Dhir, Rachna; Kumar, Rajeev; Wyman, Charles E

    2018-01-22

    Amphiphilic additives such as bovine serum albumin (BSA) and Tween have been used to improve cellulose hydrolysis by cellulases. However, there has been a lack of clarity to explain their mechanism of action in enzymatic hydrolysis of pure or low-lignin cellulosic substrates. In this work, a commercial Trichoderma reesei enzyme preparation and the amphiphilic additives BSA and Tween 20 were applied for hydrolysis of pure Avicel cellulose. The results showed that these additives only had large effects on cellulose conversion at low enzyme to substrate ratios when the reaction flasks were shaken. Furthermore, changes in the air-liquid interfacial area profoundly affected cellulose conversion, but surfactants reduced or prevented cellulase deactivation at the air-liquid interface. Not shaking the flasks or adding low amounts of surfactant resulted in near theoretical cellulose conversion at low enzyme loadings given enough reaction time. At low enzyme loadings, hydrolysis of cellulose in lignocellulosic biomass with low lignin content suffered from enhanced enzyme deactivation at the air-liquid interface.

  17. Evaluation of BAUER High Pressure Breathing Air P-2 Purification System

    DTIC Science & Technology

    1991-08-01

    and is a coalescing type separator that removes oil and water vapors suspended in the compressed air . The molecular sieve is made to adsorb oil and...filtering, moisture separation, and prevents compressed air return from the charged air storage flasks to the compressor during unit shutdown. A manual...1111111111111 1111 IE IH fil91i C NAVY EXPERIMENTAL DIVING UNIT REPORT NO. 10-91 EVALUATION OF BAUER HIGH PRESSURE BREATHING AIR P-2 PURIFICATION SYSTEM GEORGE D

  18. Evaluation of Bauer K-20 Diesel Drive High Pressure Breathing Air Compressor

    DTIC Science & Technology

    1993-12-01

    was to: A. Determine if the compressor and Purification System provides compressed air at the required pressures, flow rates, quality and cleanliness... compressed air return from the air storage flasks to the compressor during unit shut down. All four stages of the compressor are protected by safety...1993. 6. Naval Ships Technical Manual, S9086-SY-STM-0O0, Chapeter 551 1st Rev. I November 1987. Compressed Air Plants and Systems, para 551-4.2.21. 7

  19. Atmospheric Carbon Dioxide Record from In Situ Measurements at Mt. Cimone (1979-1997)

    DOE Data Explorer

    Colombo, Tiziano [Italian Meteorological Service, Sestola (MO), Italy; Santaguida, Riccardo

    1998-01-01

    Continuous atmospheric CO2 measurements have been carried out at Mt. Cimone since 1979. Since December 1988, air samples have also been collected approximately once per week in a pair of 2-L, electropolished, stainless steel cylindrical flasks. From 1979 until December 1988, a Hartmann and Braun URAS-2T NDIR gas analyzer was used for CO2 determinations. Currently, CO2 determinations are made through the use of a Siemens Ultramat-5E NDIR gas analyzer. Water vapor is eliminated by passing the air through a U-tube placed in an alcohol bath at -600°C. Calibration of the Ultramat-5E is accomplished by using two CO2-in-air working standard gases. These working standard gas concentrations are checked 10 days apart against three CO2-in-air mixtures that serve as secondary standards. The secondary standards are checked every 6 months against five other CO2-in-air primary standards. Hourly CO2 values are routinely plotted together with wind data. Anomalous concentrations and those affected by instrument failures or local sources are rejected. Atmospheric CO2 concentrations from Mt. Cimone are reported in the 1993 WMO/Scripps mole fraction scale. For further details on the measurement apparatus and sampling techniques used at Mt. Cimone, see Cundari et al. (1990).

  20. PHYSICAL AND BIOLOGICAL PARAMETERS THAT DETERMINE THE FATE OF 'P'-CHLOROPHENOL IN LABORATORY TEST SYSTEMS

    EPA Science Inventory

    Shake flask and microcosm studies were conducted to determine the fate of parachlorophenol (p-CP) in water and sediment systems and the role of sediment and nonsediment surfaces in the biodegradation process. Biodegradation of p-CP in estuarine water samples in shake flasks was s...

  1. A Volumetric Flask as a Projector

    ERIC Educational Resources Information Center

    Limsuwan, P.; Asanithi, P.; Thongpool, V.; Piriyawong, V.; Limsuwan, S.

    2012-01-01

    A lens based on liquid in the confined volume of a volumetric flask was presented as a potential projector to observe microscopic floating organisms or materials. In this experiment, a mosquito larva from a natural pond was selected as a demonstration sample. By shining a light beam from a laser pointer of any visible wavelength through the…

  2. Transport of NMHCs and halocarbons observed by CARIBIC: A case study

    NASA Astrophysics Data System (ADS)

    Baker, A. K.; Brenninkmeijer, C. A. M.; Oram, D. E.; O'Sullivan, D. A.; Schuck, T. J.; Slemr, F.

    2009-04-01

    The CARIBIC project (Civil Aircraft for the Regular Investigation of the Atmosphere Based on an Instrument Container) involves the monthly deployment of an instrument container equipped to make atmospheric measurements from onboard a long-range commercial airliner. Since December 2004, flights for the second phase of CARIBIC have been aboard a Lufthansa Airbus A340-600 traveling between Frankfurt, Germany and destinations in Asia, North America and South America. The instrument package housed in the container is fully automated and during each flight carries out a variety of real-time trace gas and aerosol measurements, and also collects 28 air samples, which are analyzed upon return to the laboratory. Routine measurements made from the sampling flasks include greenhouse gases, nonmethane hydrocarbons (NMHCs), and halocarbons; results of air sample analysis form the basis for the data discussed here. While the majority of CARIBIC samples represent background free tropospheric air and air representative of the upper troposphere/lower stratosphere, the aircraft also, less frequently, encounters air parcels influenced by more recent emissions. Here we present a case study of a round-trip flight between Frankfurt and Toronto, Canada during September 2007. During this flight, different air masses of unique origin were encountered; a number of samples were influenced by transport from the Gulf of Mexico, while others had source regions in Central and Southeast Asia. Samples from the Gulf of Mexico exhibited enhancements in C3-C6 alkanes, as well as a number of halogenated compounds with oceanic sources, such as methyl iodide and bromoform, while Asian samples had enhanced levels of combustion products (CO, acetylene, benzene) and anthropogenic halocarbons (methlyene chloride, chloroform, perchloroethylene). Additionally, a number of samples also showed stratospheric influence, and these samples were characterized by relatively depleted levels of many of the compounds measured. Characterization of the different air masses will be discussed, and these results will be compared to samples collected during other CARIBIC flights, which are representative of both background air and air masses influenced by similar source regions.

  3. Development of a circulation direct sampling and monitoring system for O2 and CO2 concentrations in the gas-liquid phases of shake-flask systems during microbial cell culture.

    PubMed

    Takahashi, Masato; Sawada, Yoshisuke; Aoyagi, Hideki

    2017-08-23

    Monitoring the environmental factors during shake-flask culture of microorganisms can help to optimise the initial steps of bioprocess development. Herein, we developed a circulation direct monitoring and sampling system (CDMSS) that can monitor the behaviour of CO 2 and O 2 in the gas-liquid phases and obtain a sample without interrupting the shaking of the culture in Erlenmeyer flasks capped with breathable culture plugs. Shake-flask culturing of Escherichia coli using this set-up indicated that a high concentration of CO 2 accumulated not only in the headspace (maximum ~100 mg/L) but also in the culture broth (maximum ~85 mg/L) during the logarithmic phase (4.5-9.0 h). By packing a CO 2 absorbent in the gas circulation unit of CDMSS, a specialised shake-flask culture was developed to remove CO 2 from the headspace. It was posited that removing CO 2 from the headspace would suppress increases in the dissolved CO 2 concentration in the culture broth (maximum ~15 mg/L). Furthermore, the logarithmic growth phase (4.5-12.0 h) was extended, the U.O.D. 580 and pH value increased, and acetic acid concentration was reduced, compared with the control. To our knowledge, this is the first report of a method aimed at improving the growth of E. coli cells without changing the composition of the medium, temperature, and shaking conditions.

  4. Accurate measurements of carbon monoxide in humid air using the cavity ring-down spectroscopy (CRDS) technique

    NASA Astrophysics Data System (ADS)

    Chen, H.; Karion, A.; Rella, C. W.; Winderlich, J.; Gerbig, C.; Filges, A.; Newberger, T.; Sweeney, C.; Tans, P. P.

    2012-09-01

    Accurate measurements of carbon monoxide (CO) in humid air have been made using the cavity ring-down spectroscopy (CRDS) technique. The measurements of CO mole fractions are determined from the strength of its spectral absorption in the near infrared region (∼1.57 μm) after removing interferences from adjacent carbon dioxide (CO2) and water vapor (H2O) absorption lines. Water correction functions that account for the dilution and pressure-broadening effects as well as absorption line interferences from adjacent CO2 and H2O lines have been derived for CO2 mole fractions between 360-390 ppm. The line interference corrections are independent of CO mole fractions. The dependence of the line interference correction on CO2 abundance is estimated to be approximately -0.3 ppb/100 ppm CO2 for dry mole fractions of CO. Comparisons of water correction functions from different analyzers of the same type show significant differences, making it necessary to perform instrument-specific water tests for each individual analyzer. The CRDS analyzer was flown on an aircraft in Alaska from April to November in 2011, and the accuracy of the CO measurements by the CRDS analyzer has been validated against discrete NOAA/ESRL flask sample measurements made on board the same aircraft, with a mean difference between integrated in situ and flask measurements of -0.6 ppb and a standard deviation of 2.8 ppb. Preliminary testing of CRDS instrumentation that employs new spectroscopic analysis (available since the beginning of 2012) indicates a smaller water vapor dependence than the models discussed here, but more work is necessary to fully validate the performance. The CRDS technique provides an accurate and low-maintenance method of monitoring the atmospheric dry mole fractions of CO in humid air streams.

  5. [Studies for analyzing restricted ingredients such as phenylbenzoimidazole sulfonic acid].

    PubMed

    Tokunaga, Hiroshi; Mori, Kenichiro; Onuki, Nahomi; Nosaka, Tomio; Doi, Kayo; Sakaguchi, Hiroshi; Fujii, Makiko; Takano, Katuhiro; Hayashi, Masato; Yoshizawa, Kenichi; Shimamura, Kimio; Sato, Nobuo

    2006-01-01

    Phenylbenzoimidazol sulfonic acid (PBS) is a kind of sunscreens in cosmetics and is nominated as the restricted ingredients in cosmetics in Japanese Pharmaceutical Affairs Act. So the analytical method for PBS was investigated by HPLC. 1.0 g of the lotions with 1.0% PBS was exactly weighed, put into a 50-mL volumetric flask. Water was added to make exactly 50 mL and this mixture was used as the sample solution. On the other hand, 1.0 g of the creams with 1.0% PBS was exactly weighed, put into a beaker. After adding 1 mL of tetrahydrofuran and dissolving the cream, that mixture was transferred to a 50-mL volumetric flask. And then the beaker was rinsed with 1 mL of tetrahydrofuran and the rinsed solution was put together into the volumetric flask. After adding water to the volumetric flask to make exactly 50 mL, this mixture was used as the sample solution. If necessary, the mixture was filtrated with a membrane filter (0.45 microm). 5.0 mL of the sample solution was pipetted and put into a 200-mL volumetric flask. After adding water to make exactly 200 mL, 20 microL of this solution was analyzed by HPLC using the ODS column (CAPCELL PAK C18 column, 4.6 mm i.d. x 250 mm), the mixture of 40 mmol/L acetic buffer (pH 3.4) and acetonitrile (3:1) with 0.8 mmol/L dodecyltrimethyl ammonium bromide and the detection wavelength of 305 nm. The working curve from 0.5 to 20.0 microg/mL showed a linear line between the concentrations of PBS and the peak areas. There was no interference of peak of PBS from the lotion and cream.

  6. 40 CFR Appendix 2 to Subpart A of... - Drilling Fluids Toxicity Test (EPA Method 1619)

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... any excess air removed by flushing the storage containers with nitrogen under pressure anytime the... on an analytical balance, adding the chemical to a 100-milliliter volumetric flask, and bringing the...

  7. 40 CFR Appendix 2 to Subpart A of... - Drilling Fluids Toxicity Test (EPA Method 1619)

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... any excess air removed by flushing the storage containers with nitrogen under pressure anytime the... on an analytical balance, adding the chemical to a 100-milliliter volumetric flask, and bringing the...

  8. 40 CFR Appendix 2 to Subpart A of... - Drilling Fluids Toxicity Test (EPA Method 1619)

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... any excess air removed by flushing the storage containers with nitrogen under pressure anytime the... on an analytical balance, adding the chemical to a 100-milliliter volumetric flask, and bringing the...

  9. 13. VIEW, LOOKING WEST FROM LEFT TO RIGHT, SHOWING HIGH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. VIEW, LOOKING WEST FROM LEFT TO RIGHT, SHOWING HIGH PRESSURE AIR FLASK ROOM AND PUMP ROOM - U.S. Naval Submarine Base, New London Submarine Escape Training Tank, Albacore & Darter Roads, Groton, New London County, CT

  10. Effect of various gases (methane, CO/sub 2/) on root development and/or mycorrhizae production on Virginia pine. [Pinus virginiana; Amanita rubescens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Russo, V.M.; Klarman, W.L.

    1975-01-01

    Various flow rates of air, air containing methane, and air containing carbon dioxide were passed through sterile, nutrient-saturated sand in one-liter flasks. Sixteen-day-old axenic seedlings of Pinus virginiana were planted either prior to or immediately following treatment of medium. Some flasks were also inoculated with Amanita rubescens, a fungus commonly mycorrhizal with P. virginiana. Seedlings were maintained under continuous illumination for 30 days at 24 C and roots were then examined to determine development and/or mycorrhizal association. Dry weights of roots and whole seedlings were measured. Root development of seedlings planted in medium prior to treatment with air increased withmore » increase of flow-rate to 1.25 liters per hour. When treated with methane or carbon-dioxide fewer seedlings with developed root systems were produced. Seedlings planted in medium colonized by A. rubescens and treated with air or air containing carbon-dioxide produced increasing numbers of developed roots as flow rate increased, but other seedlings treated with methane produced fewer developed roots with increase in flow-rate. Mycorrhizal production was maximum at flow-rates between 0.25 and 0.6 liters. Generally fewer developed roots and/or mycorrhizae were produced by seedlings planted in treated medium than on similar seedlings planted before gas treatment. Dry weights generally paralleled root development.« less

  11. Dynamic collection and analysis of volatile organic compounds from the headspace of cell cultures.

    PubMed

    Baranska, A; Smolinska, A; Boots, A W; Dallinga, J W; van Schooten, F J

    2015-10-15

    Exhaled breath has proven to be a valuable source of information about human bodies. Subtle differences between volatile organic compounds (VOCs) formed endogenously can be detected and become a base for a potential monitoring tool for health and disease. Until now, there has been a lack of biological and mechanistic knowledge of the processes involved in the production of relevant VOCs. Among the possible sources of health-related and disease-related VOCs are microorganisms found in the respiratory tract and in the gut. Other VOCs in the body are produced by cells that are influenced by the disease, for instance, due to metabolic disorders and/or inflammation. To gain insight into the in vivo production of VOCs by human cells and thus the exhaled breath composition, in vitro experiments involving relevant cells should be studied because they may provide valuable information on the production of VOCs by the affected cells. To this aim we developed and validated a system for dynamically (continuously) collecting headspace air in vitro using a Caco-2 cell line. The system allows the application of different cell lines as well as different experimental setups, including varying exposure times and treatment options while preserving cell viability. Significant correlation (p  ⩽  0.0001) between collection outputs within each studied group confirmed high reproducibility of the collection system. An example of such an application is presented here. We studied the influence of oxidative stress on the VOC composition of the headspace air of Caco-2 cells. By comparing the VOC composition of air flushed through empty culture flasks (n  =  35), flasks with culture medium (n  =  35), flasks with medium and cells (n  =  20), flasks with medium and an oxidative stressor (H2O2) (n  =  20), and flasks with medium, stressor, and cells (n  =  20), we were able to separate the effects from the stressor on the cells from all other interactions. Measurements were performed with gas chromatography time-of-flight mass spectrometry. Multivariate data analysis allowed detection of significant altered compounds in the compared groups. We found a significant change (p  ⩽  0.001) of the composition of VOCs due to the stressing of the Caco-2 cells by H2O2. A total of ten VOCs showed either increased or decreased abundance in the headspace of the cell cultures due to the presence of the H2O2 stressor.

  12. Laser-based measurements of δ13 C and δ2 H methane isotope signatures: precisions competitive with mass spectrometry methods

    NASA Astrophysics Data System (ADS)

    Yacovitch, Tara; Shorter, Joanne; Nelson, David; Herndon, Scott; Agnese, Mike; McManus, Barry; Zahniser, Mark

    2017-04-01

    In order to understand how and why methane (CH4 ) concentrations change over time, it is necessary to understand their sources and sinks. Stable isotope measurements of 13 CH4 :12 CH4 and CH3 D:12 CH4 ratios constrain the inventory of these sinks and sources. Current measurements often depend on Isotope Ratio Mass Spectrometry (IRMS), which requires extensive sample preparation including cryogenic separation of methane from air and subsequent conversion to either CO2 or H2 . Here, we detail improvements to a direct-absorption laser spectrometer that enable fast and precise measurements of methane isotope ratios (δ13 C and δ2 H ) of ambient air samples, without such sample preparation. The measurement system consists of a laser-based direct absorption spectrometer configured with a sample manifold for measurement of discrete samples (as opposed to flow-through measurements). Samples are trapped in the instrument using a rapid sample switching technique that compares each flask sample against a monitor tank sample. This approach reduces instrument drift and results in excellent precision. Precisions of 0.054 o/oo for δ13 C and 1.4 o/oo for δ2 H have been achieved (Allan-Werle deviations). These results are obtained in 20 minutes using 4 replicate comparisons to a monitor tank.

  13. Evaluation of BAUER UTILUS 10 and TRIPLEX Purification Systems

    DTIC Science & Technology

    1993-08-01

    of the test was to: A. Determine if the compressor and Purification System provides compressed air at the required pressures, flow rates, quality and...optimum filtering, moisture separation, third stage piston ring expansion/cylinder sealing and prevents compressed air return from the storage flasks to the...551 COMPRESSED AIR PLANTS AND SYSTEMS S9086-SY-STM-O0O PARA 551-4.2.2.1. 6. Navy Experimental Diving Unit Test Plan Number 93-01, Jan 93. 7. NAVSEAINST

  14. Measurement of evaporative water loss in small animals by dew-point hygrometry.

    PubMed

    Bernstein, M H; Hudson, D M; Stearns, J M; Hoyt, R W

    1977-08-01

    This paper presents the procedures and equations to be utilized for measurement of evaporative water loss (mw), by use of the dew-point hygrometer, in small animals exposed to air containing water vapor in an open-flow system. The system accounted accurately for the water evaporated from a bubble flask. In addition, hygrometric measurements of pulmocutaneous mw in pigeons (Columba livia, mean mass 0.31 kg) agreed closely with simultaneous gravimetric measurements, utilizing a desiccant in the sample stream, in a manner independently of air temperature (Ta, 20 or 40 degrees C), ambient water vapor pressure (PW, 4-16 10(2) Pa), or mw (5-66 mg-min-1). Evaporation in pigeons was independent of PW at 20 degrees C, but increased with decreasing PW at 40 degrees C, suggesting differences in ventilatory adjustments to changes in PW at the two temperatures.

  15. Background Mole Fractions of Hydrocarbons in North America Determined from NOAA Global Reference Network Data

    NASA Astrophysics Data System (ADS)

    Mielke-Maday, I.

    2015-12-01

    The National Oceanic and Atmospheric Administration (NOAA) Global Monitoring Division (GMD) maintains a global reference network for over 50 trace gas species and analyzes discrete air samples collected by this network throughout the world at the Earth System Research Laboratory in Boulder, Colorado. In particular, flask samples are analyzed for a number of hydrocarbons with policy and health relevance such as ozone precursors, greenhouse gases, and hazardous air pollutants. Because this global network's sites are remote and therefore minimally influenced by local anthropogenic emissions, these data yield information about background ambient mole fractions and can provide a context for observations collected in intensive field campaigns, such as the Front Range Air Pollution and Photochemistry Experiment (FRAPPE), the Southeast Nexus (SENEX) study, and the DISCOVER-AQ deployments. Information about background mole fractions during field campaigns is critical for calculating hydrocarbon enhancements in the region of study and for assessing the extent to which a particular region's local emissions sources contribute to these enhancements. Understanding the geographic variability of the background and its contribution to regional ambient mole fractions is also crucial for the development of realistic regulations. We present background hydrocarbon mole fractions and their ratios in North America using data from air samples collected in the planetary boundary layer at tall towers and aboard aircraft from 2008 to 2014. We discuss the spatial and seasonal variability in these data. We present trends over the time period of measurements and propose possible explanations for these trends.

  16. 41. #1 ARRESTING GEAR ENGINE AFT LOOKING FORWARD PORT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    41. #1 ARRESTING GEAR ENGINE - AFT LOOKING FORWARD PORT TO STARBOARD SHOWING ARRESTING GEAR ENGINE ACCUMULATOR, AIR FLASK, CONTROL VALVE, WITH CONTROL RAM, SHEAVES AND WIRES UNDERNEATH ENGINE STAND. - U.S.S. HORNET, Puget Sound Naval Shipyard, Sinclair Inlet, Bremerton, Kitsap County, WA

  17. Real-time analysis of δ13C- and δD-CH4 in ambient air with laser spectroscopy: Method development and intercomparison

    NASA Astrophysics Data System (ADS)

    Harris, E. J.; Eyer, S.; Mohn, J.; Röckmann, T.; Popa, E.; Lowry, D.; Nisbet, E. G.; Fisher, R. E.; Brennwald, M. S.; Fischer, H.; Emmenegger, L.; Tuzson, B.; Zellweger, C.

    2015-12-01

    Methane (CH4) is the second most important anthropogenically emitted greenhouse gas after carbon dioxide (CO2). Its mole fraction has increased from around 722 ppb in pre-industrial times to 1824 ppb in 2013 and the anthropogenic fraction is estimated to be 60 % of the total emissions. A promising approach to improve the understanding of the CH4 budget is the use of isotopologues to distinguish between various CH4 source processes. In the presented study in situ and simultaneous measurement of the three most abundant isotopologues of methane using mid-infrared laser absorption spectroscopy is demonstrated. A field-deployable, autonomous platform is realized by coupling a compact quantum cascade laser absorption spectrometer (QCLAS) to a preconcentration unit, called TRace gas EXtractor (TREX). This unit enhances CH4 mole fractions by a factor of up to 500 above ambient levels and quantitatively separates interfering trace gases such as N2O and CO2. The analytical precision of the QCLAS isotope measurement on the preconcentrated (750 ppm, parts-per-million, mmole/mole) methane is 0.1‰ and 0.5 ‰ for δ13C- and δD-CH4 at 10 min averaging time. [1] Based on replicate measurements of compressed air during a two-week intercomparison campaign, the repeatability of the TREX-QCLAS was determined to be 0.19 ‰ and 1.9 ‰ for δ13C and δD-CH4, respectively. In this intercomparison campaign the new in situ technique is compared to IRMS based on glass flask and bag sampling and real time CH4 isotope analysis by two commercially available laser spectrometers (Figure). Both laser-based analyzers were limited to methane mole fraction and δ13C-CH4 analysis, and only one of them, a cavity ring down spectrometer, was capable to deliver meaningful data for the isotopic composition. After correcting for scale offsets, the average difference between TREX-QCLAS data and bag/flask sampling-IRMS values are within the extended WMO compatibility goals of 0.2 and 5 ‰ for δ13C- and δD-CH4, respectively. Thus, the intercomparison also reveals the need for reference air samples with accurately determined isotopic composition of CH4 to further improve the interlaboratory compatibility. [1] References: [1] S. Eyer et al. (2015) submitted to AMTD

  18. [Analysis of false-positive reaction for bacterial detection of blood samples with the automated microbial detection system BacT/ALERT 3D].

    PubMed

    Zhu, Li-Wei; Yang, Xue-Mei; Xu, Xiao-Qin; Xu, Jian; Lu, Huang-Jun; Yan, Li-Xing

    2008-10-01

    This study was aimed to analyze the results of false positive reaction in bacterial detection of blood samples with BacT/ALERT 3D system, to evaluate the specificity of this system, and to decrease the false positive reaction. Each reaction flasks in past five years were processed for bacteria isolation and identification. When the initial cultures were positive, the remaining samples and the corresponding units were recultured if still available. 11395 blood samples were detected. It is worthy of note that the incubator temperature should be stabilized, avoiding fluctuation; when the cultures were alarmed, the reaction flasks showed be kept some hours for further incubation so as to trace a sharply increasing signal to support the judgement of true bacterial growth. The results indicated that 122 samples (1.07%) wee positive at initial culture, out of them 107 samples (88.7%) were found bacterial, and 15 samples (12.3%) were found nothing. The detection curves of positive samples resulted from bacterial growth showed ascent. In conclusion, maintenance of temperature stability and avoidance of temperature fluctuation in incubator could decrease the occurrence of false-positive reaction in detection process. The reaction flasks with positive results at initial culture should be recultured, and whether existence of a sharply ascending logarilhimic growth phase in bacterial growth curve should be further detected, which are helpful to distinguish false-positive reactions from true positive, and thus increase the specificity of the BacT/ALERT system.

  19. Composition and Trends of Short-Lived Trace Gases in the UT/LS over Europe Observed by the CARIBIC Aircraft

    NASA Astrophysics Data System (ADS)

    Baker, A. K.; Brenninkmeijer, C. A.; Oram, D. E.; O'Sullivan, D. A.; Slemr, F.; Schuck, T. J.

    2009-12-01

    The CARIBIC project (Civil Aircraft for the Regular Investigation of the atmosphere Based on an Instrument Container) involves the monthly deployment of an instrument container equipped to make atmospheric measurements from aboard a commercial airliner, and has operated since 2005 from aboard a Lufthansa Airbus 340-600 . Measurements from the container include in-situ trace gas and aerosol analyses and the collection of aerosol and whole air samples for post-flight laboratory analysis. Measurements made from the sampling flasks include greenhouse gas (GHG), halocarbon and nonmethane hydrocarbon (NMHC) analysis. CARIBIC flights originate in Frankfurt, Germany with routes to India, East Asia, South America, North America and Africa, and typical aircraft cruising altitudes of 10-12km allow for the monitoring of the upper troposphere/lower stratosphere (UT/LS) along these routes. Data collected during the aircraft’s departure from and return to Frankfurt provide a 4 year time series of near-monthly measurements of the composition of the UT/LS above Europe. Here we present a discussion of the composition of short-lived trace gases in the whole air samples collected above Europe during CARIBIC flights. Over 150 air samples were collected between May 2005 and July 2009, or about 4 samples per month. Of the whole air samples collected, about 45% showed influence by stratospheric air (i.e. very low values of GHG, NMHC and halocarbons, elevated O3, high potential vorticity). The remaining samples were representative of the upper troposphere; back trajectories for these samples indicate that a little over half were collected in air masses that had been in the boundary layer within the previous 8 days. The predominant source regions for these samples were the Gulf of Mexico and continental North America. Owing to their wide range of chemical lifetimes and the varying composition of emissions, short-lived trace gases transported to the UT/LS can be useful indicators of source region, photochemical processing and transport timescales of an air mass. Seasonal and longer-term trends in trace gases and trace gas composition are discussed, as well as composition of air masses having different origins. Additionally, we apply relationships between the different species, particularly the NMHC, to gain a qualitative understanding of photochemical processes occurring during transport from the boundary layer to the upper troposphere over Europe.

  20. Radiochemical Separation and Quantification of Tritium in Metallic Radwastes Generated from CANDU Type NPP - 13279

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahn, H.J.; Choi, K.C.; Choi, K.S.

    2013-07-01

    As a destructive quantification method of {sup 3}H in low and intermediate level radwastes, bomb oxidation, sample oxidation, and wet oxidation methods have been introduced. These methods have some merits and demerits in the radiochemical separation of {sup 3}H radionuclides. That is, since the bomb oxidation and sample oxidation methods are techniques using heating at high temperature, the separation methods of the radionuclides are relatively simple. However, since {sup 3}H radionuclide has a property of being diffused deeply into the inside of metals, {sup 3}H which is distributed on the surface of the metals can only be extracted if themore » methods are applied. As an another separation method, the wet oxidation method makes {sup 3}H oxidized with an acidic solution, and extracted completely to an oxidized HTO compound. However, incomplete oxidized {sup 3}H compounds, which are produced by reactions of acidic solutions and metallic radwastes, can be released into the air. Thus, in this study, a wet oxidation method to extract and quantify the {sup 3}H radionuclide from metallic radwastes was established. In particular, a complete extraction method and complete oxidation method of incomplete chemical compounds of {sup 3}H using a Pt catalyst were studied. The radioactivity of {sup 3}H in metallic radwastes is extracted and measured using a wet oxidation method and liquid scintillation counter. Considering the surface dose rate of the sample, the appropriate size of the sample was determined and weighed, and a mixture of oxidants was added to a 200 ml round flask with 3 tubes. The flask was quickly connected to the distilling apparatus. 20 mL of 16 wt% H{sub 2}SO{sub 4} was given into the 200-ml round flask through a dropping funnel while under stirring and refluxing. After dropping, the temperature of the mixture was raised to 96 deg. C and the sample was leached and oxidized by refluxing for 3 hours. At that time, the incomplete oxidized {sup 3}H compounds were completely oxidized using the Pt catalysts and produced a stable HTO compound. After that, about a 20 ml solution was distilled in the separation apparatus, and the distillate was mixed with an ultimagold LLT as a cocktail solution. The solution in the vial was left standing for at least 24 hours. The radioactivity of {sup 3}H was counted directly using a liquid scintillation analyzer (Packard, 2500 TR/AB, Alpha and Beta Liquid Scintillation Analyzer). (authors)« less

  1. Accurate measurements of carbon monoxide in humid air using the cavity ring-down spectroscopy (CRDS) technique

    NASA Astrophysics Data System (ADS)

    Chen, H.; Karion, A.; Rella, C. W.; Winderlich, J.; Gerbig, C.; Filges, A.; Newberger, T.; Sweeney, C.; Tans, P. P.

    2013-04-01

    Accurate measurements of carbon monoxide (CO) in humid air have been made using the cavity ring-down spectroscopy (CRDS) technique. The measurements of CO mole fractions are determined from the strength of its spectral absorption in the near-infrared region (~1.57 μm) after removing interferences from adjacent carbon dioxide (CO2) and water vapor (H2O) absorption lines. Water correction functions that account for the dilution and pressure-broadening effects as well as absorption line interferences from adjacent CO2 and H2O lines have been derived for CO2 mole fractions between 360-390 ppm and for reported H2O mole fractions between 0-4%. The line interference corrections are independent of CO mole fractions. The dependence of the line interference correction on CO2 abundance is estimated to be approximately -0.3 ppb/100 ppm CO2 for dry mole fractions of CO. Comparisons of water correction functions from different analyzers of the same type show significant differences, making it necessary to perform instrument-specific water tests for each individual analyzer. The CRDS analyzer was flown on an aircraft in Alaska from April to November in 2011, and the accuracy of the CO measurements by the CRDS analyzer has been validated against discrete NOAA/ESRL flask sample measurements made on board the same aircraft, with a mean difference between integrated in situ and flask measurements of -0.6 ppb and a standard deviation of 2.8 ppb. Preliminary testing of CRDS instrumentation that employs improved spectroscopic model functions for CO2, H2O, and CO to fit the raw spectral data (available since the beginning of 2012) indicates a smaller water vapor dependence than the models discussed here, but more work is necessary to fully validate the performance. The CRDS technique provides an accurate and low-maintenance method of monitoring the atmospheric dry mole fractions of CO in humid air streams.

  2. Tracking Oxidation During Transport of Trace Gases in Air from the Northern to Southern Hemisphere

    NASA Astrophysics Data System (ADS)

    Montzka, S. A.; Moore, F. L.; Atlas, E. L.; Parrish, D. D.; Miller, B. R.; Sweeney, C.; McKain, K.; Hall, B. D.; Siso, C.; Crotwell, M.; Hintsa, E. J.; Elkins, J. W.; Blake, D. R.; Barletta, B.; Meinardi, S.; Claxton, T.; Hossaini, R.

    2017-12-01

    Trace gas mole fractions contain the imprint of recent influences on an air mass such as sources, transport, and oxidation. Covariations among the many gases measured from flasks during ATom and HIPPO, and from the ongoing NOAA cooperative air sampling program enable recent influences to be identified from a wide range of sources including industrial activity, biomass burning, emissions from wetlands, and uptake by terrestrial ecosystems. In this work we explore the evolution of trace gas concentrations owing to atmospheric oxidation as air masses pass through the tropics, the atmospheric region with the highest concentrations of the hydroxyl radical. Variations in C2-C5 hydrocarbon concentrations downwind of source regions provide a measure of photochemical ageing in an air mass since emission, but they become less useful when tracking photochemical ageing as air is transported from the NH into the SH owing to their low mixing ratios, lifetimes that are very short relative to transport times, non-industrial sources in the tropics (e.g., biomass burning), and southern hemispheric sources. Instead, we consider a range of trace gases and trace gas pairs that provide a measure of photochemical processing as air transits the tropics. To be useful in this analysis, these trace gases would have lifetimes comparable to interhemispheric transport times, emissions arising from only the NH at constant relative magnitudes, and concentrations sufficient to allow precise and accurate measurements in both hemispheres. Some anthropogenically-emitted chlorinated hydrocarbons meet these requirements and have been measured during ATom, HIPPO, and from NOAA's ongoing surface sampling efforts. Consideration of these results and their implications for tracking photochemical processing in air as it is transported across the tropics will be presented.

  3. Partitioning net ecosystem carbon exchange into net assimilation and respiration using 13CO2 measurements: A cost-effective sampling strategy

    NASA Astrophysics Data System (ADS)

    OgéE, J.; Peylin, P.; Ciais, P.; Bariac, T.; Brunet, Y.; Berbigier, P.; Roche, C.; Richard, P.; Bardoux, G.; Bonnefond, J.-M.

    2003-06-01

    The current emphasis on global climate studies has led the scientific community to set up a number of sites for measuring the long-term biosphere-atmosphere net CO2 exchange (net ecosystem exchange, NEE). Partitioning this flux into its elementary components, net assimilation (FA), and respiration (FR), remains necessary in order to get a better understanding of biosphere functioning and design better surface exchange models. Noting that FR and FA have different isotopic signatures, we evaluate the potential of isotopic 13CO2 measurements in the air (combined with CO2 flux and concentration measurements) to partition NEE into FR and FA on a routine basis. The study is conducted at a temperate coniferous forest where intensive isotopic measurements in air, soil, and biomass were performed in summer 1997. The multilayer soil-vegetation-atmosphere transfer model MuSICA is adapted to compute 13CO2 flux and concentration profiles. Using MuSICA as a "perfect" simulator and taking advantage of the very dense spatiotemporal resolution of the isotopic data set (341 flasks over a 24-hour period) enable us to test each hypothesis and estimate the performance of the method. The partitioning works better in midafternoon when isotopic disequilibrium is strong. With only 15 flasks, i.e., two 13CO2 nighttime profiles (to estimate the isotopic signature of FR) and five daytime measurements (to perform the partitioning) we get mean daily estimates of FR and FA that agree with the model within 15-20%. However, knowledge of the mesophyll conductance seems crucial and may be a limitation to the method.

  4. 30 CFR 35.20 - Autogenous-ignition temperature test.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... timer shall be stopped. The test flask shall then be flushed well with clean dry air and, after a lapse... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Autogenous-ignition temperature test. 35.20..., EVALUATION, AND APPROVAL OF MINING PRODUCTS FIRE-RESISTANT HYDRAULIC FLUIDS Test Requirements § 35.20...

  5. Quantification and source identification of the Total Elgin gas leak, UK - North Sea, by aircraft sampling

    NASA Astrophysics Data System (ADS)

    Lee, J. D.; Bauguitte, S.; Wellpott, A.; Lowry, D.; Fisher, R. E.; Lewis, A. C.; Hopkins, J.; Allen, G.; O'Shea, S.; Lanoiselle, M.; France, J.; Lidster, R.; Punjabi, S.; Manning, A. J.; Ryerson, T. B.; Mobbs, S.; Gallagher, M. W.; Coe, H.; Pyle, J. A.; Nisbet, E. G.

    2012-12-01

    Aircraft measurement and air sampling have been used to quantify the source and magnitude of the North Sea Total Elgin wellhead platform gas leak in March/April 2012. Isotopic techniques were used to characterise the geological source formation from which the gas came. Initially on 30 March 2012 the leak was in the range 1.6 - 0.7 kg s-1, reducing to less than half that rate by 3 April 2012. Keeling plot analysis of methane in air samples showed that the gas had δ13CCH4 -43‰, implying that the gas source was not the main high-pressure high-temperature Elgin gas field (5.5 km deep, at 190oC) but more probably the overlying Hod Formation. The evidence in the air plume for release of very volatile NMHCs confirmed media reports that the gas leak was on the production platform, above the sea level. This contrasts with the early situation in the BP Deepwater Horizon event, where release was underwater and volatile NMHC species were taken up in the water column. Non-methane hydrocarbons (NMHC) and other volatile organic compounds in the plumes were determined from flask samples by offline analysis. NMHC content was dominated by light alkanes ranging from >20 ppb ethane to <1 ppb benzene and <0.1 ppb higher monoaromatics. The methodology developed in this work is widely applicable to future emissions of environmental concern in circumstances where direct access is difficult or dangerous, and permits unbiased regulatory assessment of potential impact, independent of the emitting party.

  6. Can We Monitor Ecosystem Function Using Keeling Plot Analyses of Nocturnal Cold-Air Drainage?

    NASA Astrophysics Data System (ADS)

    Bond, B. J.; Ocheltree, T.; Pypker, T.; Unsworth, M. H.; Mix, A. C.; William, R.

    2003-12-01

    The carbon isotope signature of ecosystem respiration, δ 13CR, as measured by the Keeling Plot approach, has been related to short-term variations in weather and ecosystem function in several recent studies. In order to obtain an adequate range of [CO2] and to sample a consistent vegetation type, investigators typically select sampling locations in relatively flat terrain and uniform canopy cover, but these are unusual conditions for many forested ecosystems. In a pilot study, we are collecting samples for Keeling Plot analyses in cold-air drainage systems in small (60-100 ha), deeply-incised watersheds, one covered with old-growth (ca 450-years-old) Douglas-fir/hemlock forest and one covered with young (ca 45-years-old) Douglas-fir forest. We found that the nightly range of [CO2] was typically 380-460 ppm, sufficient to develop good estimates of δ 13CR. At any point in time there was little variation in [CO2] with height through the canopy (0.5-30m), so the required range was obtained by sampling over several hours. There was no indication that samples taken from different heights or at different times of night represented sources with different isotopic signatures. The isotopic signature of respired CO2 in the older watershed averaged about 1 per mil greater than that of the young watershed, and δ 13CR of both locations correlated with modeled stomatal conductance 6 days prior to flask sampling.

  7. Simple Laboratory Experiment for Illustrating Soil Respiration.

    ERIC Educational Resources Information Center

    Hattey, J. A.; Johnson, G. V.

    1997-01-01

    Describes an experiment to illustrate the effect of food source and added nutrients (N) on microbial activity in the soil. Supplies include air-dried soil, dried plant material, sources of carbon and nitrogen, a trap such as KOH, colored water, and a 500-mL Erlenmeyer flask. Includes a diagram of an incubation chamber to demonstrate microbial…

  8. The Egg in the Bottle Revisited: Air Pressure and Amontons' Law (Charles' Law).

    ERIC Educational Resources Information Center

    Adcock, Louis H.

    1998-01-01

    Presents instructions for putting a hard-boiled egg inside a bottle whose opening is slightly smaller than the egg's circumference, and for getting the egg out of the bottle. Also describes variations of the demonstration such as cooling the flask or using a banana. Cites incorrect and correct explanations of the demonstrated phenomenon. Contains…

  9. Validation of AIRS Retrievals of CO2 via Comparison to In Situ Measurements

    NASA Technical Reports Server (NTRS)

    Olsen, Edward T.; Chahine, Moustafa T.; Chen, Luke L.; Jiang, Xun; Pagano, Thomas S.; Yung, Yuk L.

    2008-01-01

    Topics include AIRS on Aqua, 2002-present with discussion about continued operation to 2011 and beyond and background, including spectrum, weighting functions, and initialization; comparison with aircraft and FTIR measurements in Masueda (CONTRAIL) JAL flask measurements, Park Falls, WI FTIR, Bremen, GDF, and Spitsbergen, Norway; AIRS retrievals over addition FTIR sites in Darwin, AU and Lauder, NZ; and mid-tropospheric carbon dioxide weather and contribution from major surface sources. Slide titles include typical AIRS infrared spectrum, AIRS sensitivity for retrieving CO2 profiles, independence of CO2 solution with respect to the initial guess, available in situ measurements for validation and comparison, comparison of collocated V1.5x AIRS CO2 (N_coll greater than or equal to 9) with INTEX-NA and SPURT;

  10. Does the Exposure of Urine Samples to Air Affect Diagnostic Tests for Urine Acidification?

    PubMed Central

    Yi, Joo-Hark; Shin, Hyun-Jong; Kim, Sun-Moon; Han, Sang-Woong; Oh, Man-Seok

    2012-01-01

    Summary Background and objectives For accurate measurement of pH, urine collection under oil to limit the escape of CO2 on air exposure is recommended. This study aims to test the hypothesis that urine collection under oil is not necessary in acidic urine in which bicarbonate and CO2 are minor buffers, because loss of CO2 would have little effect on its pH. Design, setting, participants, & measurements One hundred consecutive random urine samples were collected under oil and analyzed for pH, pCO2, and HCO3− immediately and after 5 minutes of vigorous shaking in uncovered flasks to allow CO2 escape. Results The pH values in 97 unshaken samples ranged from 5.03 to 6.83. With shaking, urine pCO2 decreased by 76%, whereas urine HCO3− decreased by 60%. Meanwhile, urine baseline median pH (interquartile range) of 5.84 (5.44–6.25) increased to 5.93 (5.50–6.54) after shaking (ΔpH=0.12 [0.07–0.29], P<0.001). ΔpH with pH≤6.0 was significantly lower than the ΔpH with pH>6.0 (0.08 [0.05–0.12] versus 0.36 [0.23–0.51], P<0.001). Overall, the lower the baseline pH, the smaller the ΔpH. Conclusions The calculation of buffer reactions in a hypothetical acidic urine predicted a negligible effect on urine pH on loss of CO2 by air exposure, which was empirically proven by the experimental study. Therefore, exposure of urine to air does not substantially alter the results of diagnostic tests for urine acidification, and urine collection under oil is not necessary. PMID:22700881

  11. Pericellular oxygen monitoring with integrated sensor chips for reproducible cell culture experiments.

    PubMed

    Kieninger, J; Aravindalochanan, K; Sandvik, J A; Pettersen, E O; Urban, G A

    2014-04-01

    Here we present an application, in two tumour cell lines, based on the Sensing Cell Culture Flask system as a cell culture monitoring tool for pericellular oxygen sensing. T-47D (human breast cancer) and T98G (human brain cancer) cells were cultured either in atmospheric air or in a glove-box set at 4% oxygen, in both cases with 5% CO2 in the gas phase. Pericellular oxygen tension was measured with the help of an integrated sensor chip comprising oxygen sensor arrays. Obtained results illustrate variation of pericellular oxygen tension in attached cells covered by stagnant medium. Independent of incubation conditions, low pericellular oxygen concentration levels, usually associated with hypoxia, were found in dense cell cultures. Respiration alone brought pericellular oxygen concentration down to levels which could activate hypoxia-sensing regulatory processes in cultures believed to be aerobic. Cells in culture believed to experience conditions of mild hypoxia may, in reality, experience severe hypoxia. This would lead to incorrect assumptions and suggests that pericellular oxygen concentration readings are of great importance to obtain reproducible results when dealing with hypoxic and normoxic (aerobic) incubation conditions. The Sensing Cell Culture Flask system allows continuous monitoring of pericellular oxygen concentration with outstanding long-term stability and no need for recalibration during cell culture experiments. The sensor is integrated into the flask bottom, thus in direct contact with attached cells. No additional equipment needs to be inserted into the flask during culturing. Transparency of the electrochemical sensor chip allows optical inspection of cells attached on top of the sensor. © 2014 John Wiley & Sons Ltd.

  12. An economical 20 litre bench-top fermenter.

    PubMed

    Thiel, Michael A; Coster, Douglas J; Mavrangelos, Christos; Zola, Heddy; Williams, Keryn A

    2002-10-01

    We describe an economical 20 litre bench-top fermenter suitable for production of recombinant antibody fragments in bacterial expression systems. The bacterial culture contained within a polycarbonate carboy is mixed (400-600 rpm) and aerated (1 vessel vol./min) by a high-shear radial flow impeller mounted on a hollow stainless steel shaft, through which pressurised air is pumped. Air is dispersed as fine bubbles into the culture medium by the turbine impeller, without the need for a porous sparger. A stainless steel baffle stabilised by a gliding counterweight increases mixing. The components can easily be disassembled for cleaning and sterilisation. Temperature (range 20-37 degrees C) and pH (range 7.0-7.5) are controlled manually. Using the apparatus, it proved possible to achieve Escherichia coli cell culture densities equivalent to an optical density at 600 nm (OD(600)) of 30-32, compared with OD(600) 4-6 in shake flasks. A yield of 40 mg/litre/day of a recombinant antibody fragment was obtained with the fermenter, which was 15-fold more than the yield of 2.5mg/litre/day achieved in shake flasks. The fermenter may be particularly suited for research purposes.

  13. Ozone reactivity of biogenic volatile organic compound (BVOC) emissions during the Southeast Oxidant and Aerosol Study (SOAS)

    NASA Astrophysics Data System (ADS)

    Park, J.; Guenther, A. B.; Helmig, D.

    2013-12-01

    Recent studies on atmospheric chemistry in the forest environment showed that the total reactivity by biogenic volatile organic compound (BVOC) emission is still not well understood. During summer 2013, an intensive field campaign (Southeast Oxidant and Aerosol Study - SOAS) took place in Alabama, U.S.A. In this study, an ozone reactivity measurement system (ORMS) was deployed for the direct determination of the reactivity of foliage emissions. The ORMS is a newly developed measurement approach, in which a known amount of ozone is added to the ozone-free air sample stream, with the ORMS measuring ozone concentration difference between before and after a glass flask flow tube reaction vessel (2-3 minutes of residence time). Emissions were also collected onto adsorbent cartridges to investigate the discrepancy between total ozone reactivity observation and reactivity calculated from identified BVOC. Leaf and canopy level experiments were conducted by deploying branch enclosures on the three dominant tree species at the site (i.e. liquidambar, white oak, loblolly pine) and by sampling ambient air above the forest canopy. For the branch enclosure experiments, BVOC emissions were sampled from a 70 L Teflon bag enclosure, purged with air scrubbed for ozone, nitrogen oxides. Each branch experiment was performed for 3-5 days to collect at least two full diurnal cycle data. In addition, BVOCs were sampled using glass tube cartridges for 2 hours during daytime and 3 - 4 hours at night. During the last week of campaign, the inlet for the ORMS was installed on the top of scaffolding tower (~30m height). The ozone loss in the reactor showed distinct diurnal cycle for all three tree species investigated, and ozone reactivity followed patterns of temperature and light intensity.

  14. Laboratory and Field Evaluation of a Waterless Food Service Sanitation System Used by Military Mobile Kitchen Trailer Crews

    DTIC Science & Technology

    1993-12-01

    Stopper the flask and shake vigorously. The mixture was titrated with 0.003 N sodium lauryl sulfate drcpwise. The endpoint was the first definite...100 g sodium sulfate and 1000 mL distilled water, pill0) and three drops of 0.1% bracu 1henol blue indicator to 50 ML of sample in a 250 mL flask...Product QDS (Syncide Plus) (1) was determined by a bromcphenol blue nethod (7). Add 25 mL of chloroform, 25 mL salt buffer solution (7 g sodium carbonate

  15. Saline-filled cuffs help prevent laser-induced polyvinylchloride endotracheal tube fires.

    PubMed

    Sosis, M B; Dillon, F X

    1991-02-01

    To determine whether the filling of tracheal tube cuffs with saline would decrease their combustibility during laser surgery, 20 polyvinylchloride tracheal tubes were studied. The cuffed end of each tracheal tube was inserted into the neck of an empty flask, and the tube and flask were flushed with oxygen for 5 min before cuff inflation. Ten tracheal tubes had their cuffs inflated with air, and 10 were inflated with saline. A Lasersonics LS880 CO2 laser, set to 5 W for five of each of the two types of filled cuffs and to 40 W for the other pair of five tubes, was fired continuously at the cuffs for up to 1 min. No combustion occurred at the 5-W setting. The times to cuff perforation when the laser was set at 5 W were (mean +/- SD) 1.00 +/- 0.83 and 4.21 +/- 3.91 s for the air- and saline-filled cuffs, respectively, a difference that was not statistically significant. The time to deflation of the saline-filled cuff (104.6 +/- 67.5 s) was, however, significantly longer than that of the air-filled cuff (2.59 +/- 1.97 s). When the tracheal tube cuffs were exposed to 40-W laser radiation, the cuff and adjacent tube shaft ignited in all cases when the cuffs were inflated with air, but only in one of five cases when the cuffs were filled with saline (P less than 0.05). The filling of tracheal tube cuffs with saline provides simple, moderately effective partial protection of the cuff of endotracheal tubes during CO2 laser airway surgery.

  16. Optimization of growth for the hyperthermophilic archaeon Aeropyrum pernix on a small-batch scale.

    PubMed

    Milek, Igor; Cigic, Blaz; Skrt, Mihaela; Kaletunç, Gönül; Ulrih, Natasa Poklar

    2005-09-01

    Growth of Aeropyrum pernix, the first reported aerobic neutrophilic hyperthermophilic archaeon, was investigated under different cultivation parameters. Different sources of seawater, pH, and the cultivation methods were tested with the aim to improve the biomass production. A 1-L glass flask fitted with a condenser and air diffuser was used as a bioreactor. The optimum conditions for maximizing A. pernix biomass were obtained when Na2S2O3.5H2O (1 g/L) with added marine broth 2216 at pH 7.0 (20 mmol HEPES buffer/L) was used as a growing medium in a 1-L flask. The biomass production was 0.45 g dry cell mass/L in 40 h under the optimum conditions, which is more than the 0.42 g dry cell mass/L in 60 h previously obtained.

  17. [CO2 Budget and Atmospheric Rectification (COBRA) Over North America

    NASA Technical Reports Server (NTRS)

    2004-01-01

    The purpose of the CO2 Budget and Rectification Airborne (COBRA) study was to assess terrestrial sources and sinks of carbon dioxide using an air-borne study. The study was designed to address the measurement gap between plot-scale direct flux measurements and background hemispheric-scale constraints and to refine techniques for measuring terrestrial fluxes at regional to continental scales. The initial funded effort (reported on here) was to involve two air-borne campaigns over North America, one in summer and one in winter. Measurements for COBRA (given the acronym C02BAR in the initial proposal) were conducted from the University of North Dakota Citation 11, a twin-engine jet aircraft capable of profiling from the surface to 12 km and cruising for up to 4 hours and 175m/s. Onboard instrumentation measured concentrations of CO2, CO, and H2O, and meteorological parameters at high rates. In addition, two separate flask sampling systems collected discrete samples for laboratory analysis of CO2,CO, CH4, N2O, SF6, H2, 13CO2, C18O16O,O2/N2, and Ar/N2. The project involved a collaboration between a number of institutions, including (but not limited to) Harvard, NOAA-CMDL, the University of North Dakota, and Scripps.

  18. Transport of Gas-Phase Anthropogenic VOCs to the Remote Troposphere During the NASA ATom Mission

    NASA Astrophysics Data System (ADS)

    Hornbrook, R. S.; Apel, E. C.; Hills, A. J.; Asher, E. C. C.; Emmons, L. K.; Blake, D. R.; Blake, N. J.; Simpson, I. J.; Barletta, B.; Meinardi, S.; Montzka, S. A.; Moore, F. L.; Miller, B. R.; Sweeney, C.; McKain, K.; Wofsy, S. C.; Daube, B. C.; Commane, R.; Bui, T. V.; Hanisco, T. F.; Wolfe, G. M.; St Clair, J. M.; Ryerson, T. B.; Thompson, C. R.; Peischl, J.; Ray, E. A.

    2017-12-01

    The NASA Atmospheric Tomography (ATom) project aims to study the impact of human-produced air pollution on greenhouse gases and on chemically reactive gases in the atmosphere. During the first two deployments, ATom-1 and ATom-2, which took place August 2016 and February 2017, respectively, a suite of trace gas measurement instruments were deployed on the NASA DC-8 which profiled the atmosphere between 0.2 and 13 km from near-pole to near-pole around the globe, sampling in the most remote regions of the atmosphere over the Arctic, Pacific, Southern, and Atlantic Oceans. Volatile organic compounds (VOCs) with a range of lifetimes from days to decades quantified using the Trace Organic Gas Analyzer (TOGA), Whole Air Sampler (WAS) and Programmable Flask Packages (PFPs) demonstrate a significant impact on the remote atmosphere from urban and industrial sources. Comparisons between the transport and fate of pollutants during Northern Hemisphere summer and winter will be presented. Observations of the distributions of anthropogenic VOCs will be compared with simulations using the Community Atmosphere Model with chemistry (CAM-chem).

  19. Effect of flask vibration time on casting integrity, Surface Penetration and Coating Inclusion in lost foam casting of Al-Si Alloy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karimian, Majid; Idris, M. H.; Ourdjini, A.

    2011-01-17

    The paper presents the result of an experimental investigation conducted on medium aluminum silicon alloy casting- LM6, using no-vacuum assisted lost foam casting process. The study is directed for establishing the relationship between the flask vibrations times developed for molded sample on the casting integrity, surface penetration and coating inclusion defects of the casting. Four different flask vibration times namely 180, 120, 90 and 60 sec. were investigated. The casting integrity was investigated in terms of fulfilling in all portions and edges. The surface penetration was measured using optical microscope whilst image analyzer was used to quantify the percentage ofmore » coating inclusion in the casting. The results show that vibration time has significant influence on the fulfilling as well as the internal integrity of the lost foam casting. It was found that the lower vibration time produced comparatively sound casing.« less

  20. Flow Dynamics In Eccentrically Rotating Flasks Used For Dispersant Effectiveness Testing

    EPA Science Inventory

    The evaluation of dispersant effectiveness used for oil spills is commonly done using tests conducted in laboratory flasks. We used a Hot Wire Anemometer (HWA) to characterize mixing dynamics in the Swirling Flask (SF) and the Baffled Flask (BF), the latter is being considered b...

  1. HIPPO Experiment Data Access and Subseting System

    NASA Astrophysics Data System (ADS)

    Krassovski, Misha; Hook, Les; Christensen, Sigurd; Boden, Tom

    2014-05-01

    HIAPER Pole-to-Pole Observations (HIPPO) was an NSF- and NOAA-funded, multi-year global airborne research project to survey the latitudinal and vertical distribution of greenhouse and related gases, and aerosols. Project scientists and support staff flew five month-long missions over the Pacific Basin on the NSF/NCAR Gulfstream V, High-performance Instrumented Airborne Platform for Environmental Research (HIAPER) aircraft between January 2009 and September 2011, spread throughout the annual cycle, from the surface to 14 km in altitude, and from 87N to 67S. The landmark study resulted in an extensive, highly detailed dataset of over 90 atmospheric species, from six categories, all with navigation and atmospheric structure data, including greenhouse gases and carbon cycle gases; ozone and water vapor; black carbon and aerosols; ozone-depleting substances and their replacements; light hydrocarbons and PAN; and sulfur gases/ocean-derived gases. A suite of specialized instruments on the aircraft made high-rate measurements as the plane flew, while several whole air samplers collected flasks of air for later analysis in laboratories around the U.S. Flights were conducted in a continuously profiling mode, with the aircraft alternately climbing or descending as it flew from its home base in Broomfield, Colorado north to Alaska and the Arctic, south down the middle of the Pacific Ocean to New Zealand and the Southern Ocean near Antarctica, and then back to the Arctic a second time before returning home. In all, the aircraft made 64 flights and flew 787 vertical profiles while covering 285,000 km. Instruments collected 434 hours of high-rate continuous measurements and 4,235 flask samples were collected during the five HIPPO missions. Data from the HIPPO study of greenhouse gases and aerosols are now available to the atmospheric research community and the public. This comprehensive dataset provides the first high-resolution vertically resolved measurements of over 90 unique atmospheric species from nearly pole-to-pole over the Pacific Ocean across all seasons. The suite of atmospheric trace gases and aerosols is pertinent to understanding the carbon cycle and challenging global climate models. This dataset will provide opportunities for research across a broad spectrum of Earth sciences, including those analyzing the evolution in time and space of the greenhouse gases that affect global climate. The Carbon Dioxide Information Analysis Center (CDIAC) at Oak Ridge National Laboratory (ORNL) provides data management support for the HIPPO experiment including long-term data storage and dissemination. CDIAC has developed a relational database to house HIPPO merged 10-second meteorology, atmospheric chemistry, and aerosol data. This data set provides measurements from all Missions, 1 through 5, that took place from January of 2009 to September 2011. This presentation introduces newly build database and web interface, reflects the present state and functionality of the HIPPO Database and Exploration System as well as future plans for expansion and inclusion of combined discrete flask and GC sample GHG, Halocarbon, and hydrocarbon data.

  2. Survival of Microbial Pathogens in the Marine Environment.

    DTIC Science & Technology

    1978-05-01

    serial 10-fold dilutions were made in ocean water sterilized by filtration (0.22 iiM Millipore membrane). The I... water (salinity 28 parts per thousand, pH 7.6) was seeded with H-i virus to contain approximately 1O4 TCID~0 1 s per ml. Four’ replicate flasks were...100 ml of untreated ocean water (test flask) and to a flask of 100 ml of filtered (0.22 pM ?4illipore membrane) ocean water (control flask). The flasks

  3. Electrically conductive connection for an electrode

    DOEpatents

    Hornack, Thomas R.; Chilko, Robert J.

    1986-01-01

    An electrically conductive connection for an electrode assembly of an electrolyte cell in which aluminum is produced by electrolysis in a molten salt is described. The electrode assembly comprises an electrode flask and a conductor rod. The flask has a collar above an area of minimum flask diameter. The electrically conductive connection comprises the electrode flask, the conductor rod and a structure bearing against the collar and the conductor rod for pulling the conductor rod into compressive and electrical contact with the flask.

  4. Electrically conductive connection for an electrode

    DOEpatents

    Hornack, T.R.; Chilko, R.J.

    1986-09-02

    An electrically conductive connection for an electrode assembly of an electrolyte cell in which aluminum is produced by electrolysis in a molten salt is described. The electrode assembly comprises an electrode flask and a conductor rod. The flask has a collar above an area of minimum flask diameter. The electrically conductive connection comprises the electrode flask, the conductor rod and a structure bearing against the collar and the conductor rod for pulling the conductor rod into compressive and electrical contact with the flask. 2 figs.

  5. Methods for Aircraft State and Parameter Identification

    DTIC Science & Technology

    1975-05-01

    fast heat exchange with the air. The isolation of the flask was improved by plastic foam. See Fig. 5. A small electric heater mounted inside the...flight tests is necessary to have a check on possible changes in the caracteristics of the transducers. If Kalman filtering or corresponding techniques...negates the need for transparent plastic overlays of the flight data. thereby eliminating the coneiderable amount of parallax and distortion which is

  6. Demonstration of a Fast, Precise Propane Measurement Using Infrared Spectroscopy

    NASA Astrophysics Data System (ADS)

    Zahniser, M. S.; Roscioli, J. R.; Nelson, D. D.; Herndon, S. C.

    2016-12-01

    Propane is one of the primary components of emissions from natural gas extraction and processing activities. In addition to being an air pollutant, its ratio to other hydrocarbons such as methane and ethane can serve as a "fingerprint" of a particular facility or process, aiding in identifying emission sources. Quantifying propane has typically required laboratory analysis of flask samples, resulting in low temporal resolution and making plume-based measurements infeasible. Here we demonstrate fast (1-second), high precision (<300 ppt) measurements of propane using high resolution mid-infrared spectroscopy at 2967 wavenumbers. In addition, we explore the impact of nearby water and ethane absorption lines on the accuracy and precision of the propane measurement. Finally, we discuss development of a dual-laser instrument capable of simultaneous measurements of methane, ethane, and propane (the C1-C3 compounds), all within a small spatial package that can be easily deployed aboard a mobile platform.

  7. Cooling of Water in a Flask: Convection Currents in a Fluid with a Density Maximum

    ERIC Educational Resources Information Center

    Velasco, S.; White, J. A.; Roman, F. L.

    2010-01-01

    The effect of density inversion on the convective flow of water in a spherical glass flask cooled with the help of an ice-water bath is shown. The experiment was carried out by temperature measurements (cooling curves) taken at three different heights along the vertical diameter of the flask. Flows inside the flask are visualized by seeding the…

  8. A new wireless system for decentralised measurement of physiological parameters from shake flasks

    PubMed Central

    Vasala, Antti; Panula, Johanna; Bollók, Monika; Illmann, Lutz; Hälsig, Christian; Neubauer, Peter

    2006-01-01

    Background Shake flasks are widely used because of their low price and simple handling. Many researcher are, however, not aware of the physiological consequences of oxygen limitation and substrate overflow metabolism that occur in shake flasks. Availability of a wireless measuring system brings the possibilities for quality control and design of cultivation conditions. Results Here we present a new wireless solution for the measurement of pH and oxygen from shake flasks with standard sensors, which allows data transmission over a distance of more than 100 metres in laboratory environments. This new system was applied to monitoring of cultivation conditions in shake flasks. The at-time monitoring of the growth conditions became possible by simple means. Here we demonstrate that with typical protocols E. coli shake flask cultures run into severe oxygen limitation and the medium is strongly acidified. Additionally the strength of the new system is demonstrated by continuous monitoring of the oxygen level in methanol-fed Pichia pastoris shake flask cultures, which allows the optimisation of substrate feeding for preventing starvation or methanol overfeed. 40 % higher cell density was obtained by preventing starvation phases which occur in standard shake flask protocols by adding methanol when the respiration activity decreased in the cultures. Conclusion The here introduced wireless system can read parallel sensor data over long distances from shake flasks that are under vigorous shaking in cultivation rooms or closed incubators. The presented technology allows centralised monitoring of decentralised targets. It is useful for the monitoring of pH and dissolved oxygen in shake flask cultures. It is not limited to standard sensors, but can be easily adopted to new types of sensors and measurement places (e.g., new sensor points in large-scale bioreactors). PMID:16504107

  9. Adsorptive loss of secreted recombinant proteins in transgenic rice cell suspension cultures.

    PubMed

    Kwon, Jun-Young; Lee, Kyoung-Hoon; Cheon, Su-Hwan; Ryu, Hyun-Nam; Kim, Sun Jin; Kim, Dong-Il

    2012-03-01

    Adsorptive loss of human cytotoxic T-lymphocyte antigen 4-immunoglobulin (hCTLA4Ig) in transgenic rice cell suspension cultures was investigated using glass flasks, plastic flasks, disposable vessels, and stainless steel vessels. When hCTLA4Ig was added to the glass flasks containing sterile AA medium, a rapid decrease in the concentration of hCTLA4Ig, independent on pH, was observed resulting in more than 90% of the protein loss within 1 h due to the surface adsorption. When the same experiments were performed on four different types of culture equipments mentioned above, the lowest adsorption level was observed in the plastic flasks and the highest level was observed in the glass flasks. The use of the plastic flasks retarded the adsorptive loss of hCTLA4Ig at the early stage of the protein production. There was a significant increase in the production of hCTLA4Ig when the flasks were coated with bovine serum albumin. However, the spike test of purified hCTLA4Ig at two different concentrations of 15 and 100 mg L(-1) in 500-mL spinner flasks confirmed that the amount of hCTLA4Ig adsorbed was dependent on the surface area of the flasks but not on the concentrations. In conclusion, although the protein adsorption affected the total amount of the protein yielded to some extent, it could be regarded as a minor factor in transgenic plant cell cultures with higher titer.

  10. Atmospheric Methyl Chloride

    DOE Data Explorer

    Khalil, M. A. K. [Portland State Univ., Portland, OR (United States); Rasmussen, R. A. [Oregon Graduate Institute, Portland, OR (USA)

    1999-01-01

    This data set provides monthly average concentrations of atmospheric methyl chloride taken from seven locations distributed among the polar, middle, and tropical latitudes of both hemispheres. The seven primary sites include Pt. Barrow, Alaska; Cape Kumukahi and Mauna Loa, Hawaii; Cape Matatula, Samoa; Cape Grim, Tasmania; and the South Pole and Palmer Station, Antarctica. Concentration measurements from these seven sites cover a period of 16 years, extending from 1981-1997. Monthly data taken between 1987-1989 from 20 short-term sites and vertical distribution measured at various latitudes are also provided. Air samples were collected from various sites in stainless steel flasks and methyl chloride concentrations were measured using an Electron Capture Gas Chromatograph. Concentrations are reported as mixing ratios in dry air. The concentrations are determined by using a set of calibration standards that are referenced against a primary standard which is also used to establish the absolute concentration. The primary standards were prepared by the investigators in the absence of an available standard from a centralized location. The data are useful in global methyl chloride budget analyses and for determining the atmospheric distribution and trends of methyl chloride and estimating the total emissions at various latitudes.

  11. Growth of cultured corneal endothelial cells onto a vitreous carbon matrix.

    PubMed

    Wickham, M G; Cleveland, P H; Binder, P S; Akers, P H

    1983-01-01

    Fourth passage cells of a rabbit corneal endothelial line were grown for 1 week in flasks containing pieces of a reticulated vitreous carbon matrix. The rate of cell growth in flasks containing the matrix was consistent with that in control flasks. Small fragments of the vitreous carbon material lying on the flask floor were covered by the monolayers as the cells grew to confluency. Vertical growth of cells onto larger pieces of the matrix proceeded in a staged fashion with maximum cell density on pieces of the matrix closest to the floor of the flask. As defined by scanning electron microscopy, cell growth occurred to a level at least 600 microns above the floor of the flask and the confluent monolayer. This novel culture procedure should be a model situation for study of many different aspects of the in vitro capabilities of corneal endothelial cells.

  12. Variations of GHGs from the lower-troposphere to the UT/LS revealed by two Japanese regular aircraft observation programs

    NASA Astrophysics Data System (ADS)

    Niwa, Yosuke; Machida, Toshinobu; Sawa, Yousuke; Tsuboi, Kazuhiro; Matsueda, Hidekazu; Imasu, Ryoichi

    2014-05-01

    A Japan-centered observation network consisting of two regular aircraft programs have revealed the greenhouse gases variations from the lower-troposphere to the upper-troposphere/lower-stratosphere (UT/LS) regions. In the Comprehensive Observation Network for Trace gases by Airliner (CONTRAIL) project, in-situ continuous measurement equipment (CME) onboard commercial passenger aircraft world-widely observes CO2 profiles in vertical over tens of airports and in horizontal in the UT/LS regions. The CONTRAIL-CME has revealed three-dimensional structure of the global CO2 distribution and has exposed significant inter-hemispheric transport of CO2 through the upper-troposphere. In inverse modeling, the CME data have provided strong constraints on CO2 flux estimation especially for the Asian tropics. Automatic flask air sampling equipment (ASE) is also onboard the CONTRAIL aircraft and has been observing CO2 mixing ratios as well as those of methane, carbon monoxide, nitrous oxide and other trace species in the upper-troposphere between Japan and Australia. The observation period of the ASE has reached 20 years. In recent years, the ASE program has extended to the northern subarctic UT/LS region and has given an insight of transport mechanisms in the UT/LS by observing seasonal GHGs variations. In the other aircraft observation program by Japan Meteorological Agency, variations of GHGs have been observed by flask-sampling onboard a C-130H aircraft horizontally in the mid-troposphere over the western North Pacific as well as vertically over Minamitorishima-Island. The C-130H aircraft has persistently observed high mixing ratios of CH4 in the mid-troposphere, which seems to be originated from fossil fuel combustion throughout the year as well as from biogenic sources during summer in the Asian regions. Those above aircraft observation programs have a significant role for constraining GHGs flux estimates by filling the data gap of the existing surface measurement network specifically in the regions of Asia and the western North Pacific.

  13. On Road Study of Colorado Front Range Greenhouse Gases Distribution and Sources

    NASA Astrophysics Data System (ADS)

    Petron, G.; Hirsch, A.; Trainer, M. K.; Karion, A.; Kofler, J.; Sweeney, C.; Andrews, A.; Kolodzey, W.; Miller, B. R.; Miller, L.; Montzka, S. A.; Kitzis, D. R.; Patrick, L.; Frost, G. J.; Ryerson, T. B.; Robers, J. M.; Tans, P.

    2008-12-01

    The Global Monitoring Division and Chemical Sciences Division of the NOAA Earth System Research Laboratory have teamed up over the summer 2008 to experiment with a new measurement strategy to characterize greenhouse gases distribution and sources in the Colorado Front Range. Combining expertise in greenhouse gases measurements and in local to regional scales air quality study intensive campaigns, we have built the 'Hybrid Lab'. A continuous CO2 and CH4 cavity ring down spectroscopic analyzer (Picarro, Inc.), a CO gas-filter correlation instrument (Thermo Environmental, Inc.) and a continuous UV absorption ozone monitor (2B Technologies, Inc., model 202SC) have been installed securely onboard a 2006 Toyota Prius Hybrid vehicle with an inlet bringing in outside air from a few meters above the ground. To better characterize point and distributed sources, air samples were taken with a Portable Flask Package (PFP) for later multiple species analysis in the lab. A GPS unit hooked up to the ozone analyzer and another one installed on the PFP kept track of our location allowing us to map measured concentrations on the driving route using Google Earth. The Hybrid Lab went out for several drives in the vicinity of the NOAA Boulder Atmospheric Observatory (BAO) tall tower located in Erie, CO and covering areas from Boulder, Denver, Longmont, Fort Collins and Greeley. Enhancements in CO2, CO and destruction of ozone mainly reflect emissions from traffic. Methane enhancements however are clearly correlated with nearby point sources (landfill, feedlot, natural gas compressor ...) or with larger scale air masses advected from the NE Colorado, where oil and gas drilling operations are widespread. The multiple species analysis (hydrocarbons, CFCs, HFCs) of the air samples collected along the way bring insightful information about the methane sources at play. We will present results of the analysis and interpretation of the Hybrid Lab Front Range Study and conclude with perspectives on how we will adapt the measurement strategy to study CO2 anthropogenic emissions in Denver Basin.

  14. EVALUATION OF MIXING ENERGY IN FLASKS USED FOR DISPERSANT EFFECTIVENESS TESTING

    EPA Science Inventory

    A U.S. Environmental Protection Agency (EPA) laboratory screening protocol for dispersant effectiveness consists of placing water, oil, and a dispersant in a flask and mixing the contents on an orbital shaker. Two flasks are being investigated, a simple Erlenmeyer (used in EPA's...

  15. Temperature-Jump Relaxation Kinetics at Liquid/Solid Interfaces: Fluorescence Thermometry of Porous Silica Heated by a Joule Discharge

    DTIC Science & Technology

    1991-05-22

    for understanding reaction mechanisms responsible for the steady-state behavior and determining the dispersion of rates in cases where inhomogeneities...derivatized by the following procedure. Three grams of the silica was placed in a dry reaction vessel consisting of a three neck flask, addition funnel...to the reaction vessel , taking care to avoid contact with the air. A five-fold molar equivalent excess of ODS (based on the silanol 8 density of the

  16. Phytase production by Sporotrichum thermophile in a cost-effective cane molasses medium in submerged fermentation and its application in bread.

    PubMed

    Singh, B; Satyanarayana, T

    2008-12-01

    Phytase production by Sporotrichum thermophile in a cost-effective cane molasses medium in submerged fermentation and its application in bread. The production of phytase by a thermophilic mould S. thermophile was investigated using free and immobilized conidiospores in cane molasses medium in shake flasks, and stirred tank and air-lift fermenters. Among surfactants tested, Tweens (Tween-20, 40 and 80) and sodium oleate increased phytase accumulation, whereas SDS and Triton X-100 inhibited the enzyme production. The mould produced phytase optimally at a(w) 0.95, and it declined sharply below this a(w) value. The enzyme production was comparable in air-lift and stirred tank reactors with a marked reduction in fermentation time. Among the matrices tried, Ca-alginate was the best for conidiospore immobilization, and fungus secreted sustained levels of enzyme titres over five cycles. The phytic acid in the dough was efficiently hydrolysed by the enzyme accompanied by the liberation of soluble phosphate in the bread. The phytase production by S. thermophile was enhanced in the presence of Tween-80 in cane molasses medium. A peak in enzyme production was attained in 48 h in the fermenter when compared with that of 96 h in shake flasks. Ca-alginate immobilized conidiospores germinated to produce fungal growth that secreted sustained levels of phytase over five cycles. The bread made with phytase contained reduced level of phytic acid and a high-soluble phosphate. The phytase accumulation by S. thermophile was increased by the surfactants. The sustainability of enzyme production in stirred tank and air-lift fermenters suggested the possibility for scaling up of phytase. The bread made with phytase contained low level of antinutrient, i.e. phytic acid.

  17. Revisiting the round bottom flask rainbow experiment

    NASA Astrophysics Data System (ADS)

    Selmke, Markus; Selmke, Sarah

    2018-01-01

    A popular demonstration experiment in optics uses a round-bottom flask filled with water to project a circular rainbow on a screen with a hole through which the flask is illuminated. We show how the vessel's wall shifts the first- and second-order bows towards each other and consequently reduces the width of Alexander's dark band. We address the challenge this introduces in observing Alexander's dark band, and explain the importance of a sufficient distance between the flask and the screen. The wall-effect also introduces a splitting of the bows that can easily be misinterpreted.

  18. Culture expansion of adipose derived stromal cells. A closed automated Quantum Cell Expansion System compared with manual flask-based culture.

    PubMed

    Haack-Sørensen, Mandana; Follin, Bjarke; Juhl, Morten; Brorsen, Sonja K; Søndergaard, Rebekka H; Kastrup, Jens; Ekblond, Annette

    2016-11-16

    Adipose derived stromal cells (ASCs) are a rich and convenient source of cells for clinical regenerative therapeutic approaches. However, applications of ASCs often require cell expansion to reach the needed dose. In this study, cultivation of ASCs from stromal vascular fraction (SVF) over two passages in the automated and functionally closed Quantum Cell Expansion System (Quantum system) is compared with traditional manual cultivation. Stromal vascular fraction was isolated from abdominal fat, suspended in α-MEM supplemented with 10% Fetal Bovine Serum and seeded into either T75 flasks or a Quantum system that had been coated with cryoprecipitate. The cultivation of ASCs from SVF was performed in 3 ways: flask to flask; flask to Quantum system; and Quantum system to Quantum system. In all cases, quality controls were conducted for sterility, mycoplasmas, and endotoxins, in addition to the assessment of cell counts, viability, immunophenotype, and differentiation potential. The viability of ASCs passage 0 (P0) and P1 was above 96%, regardless of cultivation in flasks or Quantum system. Expression of surface markers and differentiation potential was consistent with ISCT/IFATS standards for the ASC phenotype. Sterility, mycoplasma, and endotoxin tests were consistently negative. An average of 8.0 × 10 7 SVF cells loaded into a Quantum system yielded 8.96 × 10 7 ASCs P0, while 4.5 × 10 6 SVF cells seeded per T75 flask yielded an average of 2.37 × 10 6 ASCs-less than the number of SVF cells seeded. ASCs P1 expanded in the Quantum system demonstrated a population doubling (PD) around 2.2 regardless of whether P0 was previously cultured in flasks or Quantum, while ASCs P1 in flasks only reached a PD of 1.0. Manufacturing of ASCs in a Quantum system enhances ASC expansion rate and yield significantly relative to manual processing in T-flasks, while maintaining the purity and quality essential to safe and robust cell production. Notably, the use of the Quantum system entails significantly reduced working hours and thereby costs.

  19. A comparison of impact force reduction by polymer materials used for mouthguard fabrication.

    PubMed

    Gawlak, Dominika; Mańka-Malara, Katarzyna; Mierzwińska-Nastalska, Elżbieta; Gieleta, Roman; Kamiński, Tomasz; Łuniewska, Magdalena

    2017-01-01

    The essential function of mouthguards is protection against the effects of injuries sustained during sports activities. This purpose will be successfully achieved if appropriate materials ensuring sufficient reduction of the injury force are used for mouthguard fabrication. The objective of the study was to investigate the force reduction capability of selected materials as well as to identify which material reduces the impact force to the highest degree. The material for the study were samples of polymers (6 samples in total), obtained during the process of deep pressing (2 samples), flasking (3 samples) and thermal injection (1 sample), which were tested for impact force damping using an impact device - Charpy impact hammer. The control group comprised of the ceramic material samples subjected to the hammer impact. The statistical analysis applied in this study were one-way Welch ANOVA with post-hoc Games-Howell pairwise comparisons. The test materials reduced the impact force of the impact hammer to varying degrees. The greatest damping capability was demonstrated for the following materials: Impak with 1:1 powder-to-liquid weight ratio polymerized with the conventional flasking technique, and Corflex Orthodontic used in the thermal injection technique of mouthguard fabrication. Impak with 1:1 weight ratio and Corflex Orthodontic should be recommended for the fabrication of mouthguards since they demonstrated the most advantageous damping properties.

  20. Shipboard monitoring of non-CO2 greenhouse gases in Asia and Oceania using commercially cargo vessels

    NASA Astrophysics Data System (ADS)

    Nara, H.; Tanimoto, H.; Mukai, H.; Nojiri, Y.; Tohjima, Y.; Machida, T.; Hashimoto, S.

    2011-12-01

    The National Institute for Environmental Studies (NIES) has been performing a long-term program for monitoring trace gases of atmospheric importance over the Pacific Ocean since 1995. The NIES Voluntary Observing Ships (NIES-VOS) program currently makes use of commercial cargo vessels because they operate regularly over fixed routes for long periods and sail over a wide area between various ports (e.g., between Japan and the United States, between Japan and Australia/New Zealand, and between Japan and southeast Asia). This program allows systematic and continuous measurements of non-CO2 greenhouse gases, providing long-term datasets for background air over the Pacific Ocean and regionally polluted air around east Asia. We observe both long-lived greenhouse gases (e.g., carbon dioxide) and short-lived air pollutants (e.g., tropospheric ozone, carbon monoxide) on a continuous basis. Flask samples are collected for later laboratory analysis of carbon dioxide, methane, nitrous oxide, and carbon monoxide by using gas chromatographic techniques. In addition, we recently installed cavity ringdown spectrometers for high-resolution measurement of methane and carbon dioxide to capture their highly variable features in regionally polluted air around southeast Asia (e.g., Hong Kong, Thailand, Singapore, Malaysia, Indonesia and Philippine), which is now thought to be a large source due to expanding socioeconomic activities as well as biomass burnings. Contrasting the Japan-Australia/New Zealand and Japan-southeast Asia cruises revealed regional characteristics of sources and sinks of these atmospherically important species, suggesting the existence of additional sources for methane, nitrous oxides, and carbon monoxide in this tropical Asian region.

  1. Engineering Considerations for Hydroxide Treatment of Training Ranges

    DTIC Science & Technology

    2007-06-01

    solutions were compared to the untreated controls. [14C] labeled samples were counted on a Packard Instruments liquid scin - tillation counter (Model...and the soil was removed to a scin - tillation vial. Unlabeled flasks had the soil and liquid analyzed for TOC and the liquid analyzed for anion content

  2. CARVE Measurements of Atmospheric Methane Concentrations and Emissions in Arctic and Boreal Alaska

    NASA Astrophysics Data System (ADS)

    Miller, C. E.; Miller, J. B.; Chang, R. Y.; Sweeney, C.; Karion, A.; Wofsy, S. C.; Henderson, J.; Eluszkiewicz, J.; Mountain, M.; Oechel, W. C.

    2013-12-01

    The Carbon in Arctic Reservoirs Vulnerability Experiment (CARVE) is a NASA Earth Ventures (EV-1) investigation designed to quantify correlations between atmospheric and surface state variables for the Alaskan terrestrial ecosystems through intensive seasonal aircraft campaigns, ground-based observations, and analysis sustained over a 5-year mission. CARVE bridges critical gaps in our knowledge and understanding of Arctic ecosystems, linkages between the Arctic hydrologic and terrestrial carbon cycles, and the feedbacks from fires and thawing permafrost. We present CARVE airborne measurements of spatial and temporal patterns in atmospheric CH4 concentrations and estimated surface-atmosphere emissions for Arctic and Boreal Alaska. Continuous in situ CH4, CO2 and CO data are supplemented by periodic whole air flask samples from which 13CH4 and non-methane hydrocarbons are used to assess the relative contributions of wetlands, fossil fuel combustion, and oil and gas production to the observed CH4 signals. The CARVE project has also initiated monthly 14CH4 sampling at Barrow, AK (BRW) and the CARVE Tower in Fox, AK (CRV) to evaluate seasonal changes in the fraction of old carbon being mobilized via methanogenesis.

  3. Three-dimensional (3D) evaluation of liquid distribution in shake flask using an optical fluorescence technique.

    PubMed

    Azizan, Amizon; Büchs, Jochen

    2017-01-01

    Biotechnological development in shake flask necessitates vital engineering parameters e.g. volumetric power input, mixing time, gas liquid mass transfer coefficient, hydromechanical stress and effective shear rate. Determination and optimization of these parameters through experiments are labor-intensive and time-consuming. Computational Fluid Dynamics (CFD) provides the ability to predict and validate these parameters in bioprocess engineering. This work provides ample experimental data which are easily accessible for future validations to represent the hydrodynamics of the fluid flow in the shake flask. A non-invasive measuring technique using an optical fluorescence method was developed for shake flasks containing a fluorescent solution with a waterlike viscosity at varying filling volume (V L  = 15 to 40 mL) and shaking frequency ( n  = 150 to 450 rpm) at a constant shaking diameter (d o  = 25 mm). The method detected the leading edge (LB) and tail of the rotating bulk liquid (TB) relative to the direction of the centrifugal acceleration at varying circumferential heights from the base of the shake flask. The determined LB and TB points were translated into three-dimensional (3D) circumferential liquid distribution plots. The maximum liquid height (H max ) of the bulk liquid increased with increasing filling volume and shaking frequency of the shaking flask, as expected. The toroidal shapes of LB and TB are clearly asymmetrical and the measured TB differed by the elongation of the liquid particularly towards the torus part of the shake flask. The 3D liquid distribution data collected at varying filling volume and shaking frequency, comprising of LB and TB values relative to the direction of the centrifugal acceleration are essential for validating future numerical solutions using CFD to predict vital engineering parameters in shake flask.

  4. CRYOGENIC DEWAR

    DOEpatents

    Chamberlain, W.H.; Maseck, H.E.

    1964-01-28

    This patent relates to a dewar for storing cryogenic gase and is of the type having aii inner flask surrounded by a vacuum jacket and having a vent spout through which evaporating gas escapes. Heretofore substantial gas loss has resulted from the radiation of heat towards the flask from the warmer outer elements of the dewar. In this invention, the mask is surrounded by a thermally conducting shield which is disposed in the vacuum space between the flask and the outer elements of the dewar. The shield contacts only the vent spout, which is cooled by the evaporating gas, and thus is maintained at a temperature very close to that of the flask itself. Accordingly, heat radiated toward the flask is intercepted and conducted to the evaporating gas rather than being re-radiated towards the hask. In a liquid helium dewar of typical configniration the mention reduces the boil-off rate by approximately one-half.(AEC)

  5. Double-pulse 2-μm integrated path differential absorption lidar airborne validation for atmospheric carbon dioxide measurement.

    PubMed

    Refaat, Tamer F; Singh, Upendra N; Yu, Jirong; Petros, Mulugeta; Remus, Ruben; Ismail, Syed

    2016-05-20

    Field experiments were conducted to test and evaluate the initial atmospheric carbon dioxide (CO2) measurement capability of airborne, high-energy, double-pulsed, 2-μm integrated path differential absorption (IPDA) lidar. This IPDA was designed, integrated, and operated at the NASA Langley Research Center on-board the NASA B-200 aircraft. The IPDA was tuned to the CO2 strong absorption line at 2050.9670 nm, which is the optimum for lower tropospheric weighted column measurements. Flights were conducted over land and ocean under different conditions. The first validation experiments of the IPDA for atmospheric CO2 remote sensing, focusing on low surface reflectivity oceanic surface returns during full day background conditions, are presented. In these experiments, the IPDA measurements were validated by comparison to airborne flask air-sampling measurements conducted by the NOAA Earth System Research Laboratory. IPDA performance modeling was conducted to evaluate measurement sensitivity and bias errors. The IPDA signals and their variation with altitude compare well with predicted model results. In addition, off-off-line testing was conducted, with fixed instrument settings, to evaluate the IPDA systematic and random errors. Analysis shows an altitude-independent differential optical depth offset of 0.0769. Optical depth measurement uncertainty of 0.0918 compares well with the predicted value of 0.0761. IPDA CO2 column measurement compares well with model-driven, near-simultaneous air-sampling measurements from the NOAA aircraft at different altitudes. With a 10-s shot average, CO2 differential optical depth measurement of 1.0054±0.0103 was retrieved from a 6-km altitude and a 4-GHz on-line operation. As compared to CO2 weighted-average column dry-air volume mixing ratio of 404.08 ppm, derived from air sampling, IPDA measurement resulted in a value of 405.22±4.15  ppm with 1.02% uncertainty and 0.28% additional bias. Sensitivity analysis of environmental systematic errors correlates the additional bias to water vapor. IPDA ranging resulted in a measurement uncertainty of <3  m.

  6. Effects of different fermentation methods on bacterial cellulose and acid production by Gluconacetobacter xylinus in Cantonese-style rice vinegar.

    PubMed

    Fu, Liang; Chen, Siqian; Yi, Jiulong; Hou, Zongxia

    2014-07-01

    A strain of acidogenic bacterium was isolated from the fermentation liquid of Cantonese-style rice vinegar produced by traditional surface fermentation. 16S rDNA identification confirmed the bacterium as Gluconacetobacter xylinus, which synthesizes bacterial cellulose, and the acid productivity of the strain was investigated. In the study, the effects of the membrane integrity and the comparison of the air-liquid interface membrane with immerged membrane on total acidity, cellulose production, alcohol dehydrogenase (ADH) activity and number of bacteria were investigated. The cellulose membrane and the bacteria were observed under SEM for discussing their relationship. The correlations between oxygen consumption and total acid production rate were compared in surface and shake flask fermentation. The results showed the average acid productivity of the strain was 0.02g/(100mL/h), and the integrity of cellulose membrane in surface fermentation had an important effect on total acidity and cellulose production. With a higher membrane integrity, the total acidity after 144 h of fermentation was 3.75 g/100 mL, and the cellulose production was 1.71 g/100 mL after 360 h of fermentation. However, when the membrane was crushed by mechanical force, the total acidity and the cellulose production were as low as 0.36 g/100 mL and 0.14 g/100 mL, respectively. When the cellulose membrane was forced under the surface of fermentation liquid, the total acid production rate was extremely low, but the activity of ADH in the cellulose membrane was basically the same with the one above the liquid surface. The bacteria were mainly distributed in the cellulose membrane during the fermentation. The bacterial counts in surface fermentation were more than in the shake flask fermentation and G. xylinus consumed the substrate faster, in surface fermentation than in shake flask fermentation. The oxygen consumption rate and total acid production rate of surface fermentation were respectively 26.13 times and 2.92 times that of shake flask fermentation.

  7. A vacuum-operated pore-water extractor for estuarine and freshwater sediments

    USGS Publications Warehouse

    Winger, Parley V.; Lasier, Peter J.

    1991-01-01

    A vacuum-operated pore-water extractor for estuarine and freshwater sediments was developed and constructed from a fused-glass air stone attached with aquarium airline tubing to a 30 or 60 cc polypropylene syringe. Pore water is extracted by inserting the air stone into the sediment and creating a vacuum by retracting and bracing the syringe plunger. A hand-operated vacuum pump attached to a filtration flask was also evaluated as an alternative vacuum source. The volume and time to extract pore water varies with the number of devices and the sediment particle size. Extraction time is longer for fine sediments than for sandy sediments. Four liters of sediment generally yield between 500 and 1,500 mL of pore water. The sediment that surrounds and accumulates on the air stone acts as a filter, and, except for the first few milliliters, the collected pore water is clear. Because there is no exposure to air or avenue for escape, volatile compounds andin situ characteristics are retained in the extracted pore water.

  8. Characteristics of atmospheric carbon monoxide at a high-mountain background station in East Asia

    NASA Astrophysics Data System (ADS)

    Ou-Yang, Chang-Feng; Lin, Neng-Huei; Lin, Chia-Ching; Wang, Sheng-Hsiang; Sheu, Guey-Rong; Lee, Chung-Te; Schnell, Russell C.; Lang, Patricia M.; Kawasato, Taro; Wang, Jia-Lin

    2014-06-01

    Atmospheric CO were monitored at the Lulin Atmospheric Background Station (LABS) with an elevation of 2862 m AMSL from April 2006 to April 2011 by the in-situ non-dispersive infrared (NDIR) spectrometer and weekly flask sample collections via collaboration with NOAA/ESRL/GMD. In general very coherent results were observed between the two datasets, despite a slight difference between the two. A distinct seasonal pattern of CO was noticed at the LABS with a springtime maximum and a summertime minimum, which was predominately shaped by the long-range transport of biomass burning air masses from Southeast Asia and oceanic influences from the Pacific, respectively. Diurnal cycles were also observed at the LABS, with a maximum in late afternoon and a minimum in early morning. The daytime CO maximum was most likely caused by the up-slope transport of lower elevation air. After filtering out the possibly polluted data points from the entire dataset with a mathematic procedure, the mean background CO level at the LABS was assessed as 129.3 ± 46.6 ppb, compared to 149.0 ± 72.2 ppb prior to the filtering. The cluster analysis of the backward trajectories revealed six possible source regions, which shows that air masses originating from the Westerly Wind Zone were dominated in spring and winter resulting in higher CO concentrations. As a contrast, the oceanic influences from the Pacific were found mostly in summer, contributing a lower seasonal CO concentration throughout a year.

  9. Fluid Dynamics Appearing during Simulated Microgravity Using Random Positioning Machines

    PubMed Central

    Stern, Philip; Casartelli, Ernesto; Egli, Marcel

    2017-01-01

    Random Positioning Machines (RPMs) are widely used as tools to simulate microgravity on ground. They consist of two gimbal mounted frames, which constantly rotate biological samples around two perpendicular axes and thus distribute the Earth’s gravity vector in all directions over time. In recent years, the RPM is increasingly becoming appreciated as a laboratory instrument also in non-space-related research. For instance, it can be applied for the formation of scaffold-free spheroid cell clusters. The kinematic rotation of the RPM, however, does not only distribute the gravity vector in such a way that it averages to zero, but it also introduces local forces to the cell culture. These forces can be described by rigid body analysis. Although RPMs are commonly used in laboratories, the fluid motion in the cell culture flasks on the RPM and the possible effects of such on cells have not been examined until today; thus, such aspects have been widely neglected. In this study, we used a numerical approach to describe the fluid dynamic characteristic occurring inside a cell culture flask turning on an operating RPM. The simulations showed that the fluid motion within the cell culture flask never reached a steady state or neared a steady state condition. The fluid velocity depends on the rotational velocity of the RPM and is in the order of a few centimeters per second. The highest shear stresses are found along the flask walls; depending of the rotational velocity, they can reach up to a few 100 mPa. The shear stresses in the “bulk volume,” however, are always smaller, and their magnitude is in the order of 10 mPa. In conclusion, RPMs are highly appreciated as reliable tools in microgravity research. They have even started to become useful instruments in new research fields of mechanobiology. Depending on the experiment, the fluid dynamic on the RPM cannot be neglected and needs to be taken into consideration. The results presented in this study elucidate the fluid motion and provide insight into the convection and shear stresses that occur inside a cell culture flask during RPM experiments. PMID:28135286

  10. Emissions from oil and natural gas operations in northeastern Utah

    NASA Astrophysics Data System (ADS)

    Petron, G.; Kofler, J. D.; Frost, G. J.; Miller, B. R.; Edwards, P. M.; Dube, W. P.; Montzka, S. A.; Helmig, D.; Hueber, J.; Karion, A.; Sweeney, C.; Conley, S. A.; Brown, S. S.; Geiger, F.; Warneke, C.; Martin, R. S.; Andrews, A. E.; Dlugokencky, E. J.; Lang, P. M.; Trainer, M.; Hardesty, R.; Schnell, R. C.; Tans, P. P.

    2012-12-01

    The Uintah oil and natural gas Basin in Northeastern Utah experienced several days of high ozone levels in early 2011 during cold temperature inversions. To study the chemical and meteorological processes leading to these wintertime ozone pollution events, the State of Utah, EPA region 8 and oil and gas operators pulled together a multi-agency research team, including NOAA ESRL/CIRES scientists. The data gathering took place between January 15 and February 29, 2012.To document the chemical signature of various sources in the Basin, we outfitted a passenger van with in-situ analyzers (Picarro: CH4, CO2, CO, H2O, 13CH4; NOxCaRD: NO, NOx, 2B & NOxCaRD: O3) meteorological sensors, GPS units, discrete flask sampling apparatus, as well as a data logging and "real-time" in-situ data visualization system. The instrumented van, called Mobile Lab, also hosted a KIT Proton Transfer Reaction Mass Spectrometer (suite of VOCs in situ measurements) for part of the campaign. For close to a month, the Mobile Lab traveled the roads of the oil and gas field, documenting ambient levels of several tracers. Close to 180 valid air samples were collected in February by the Mobile Lab for future analysis in the NOAA and CU/INSTAAR labs in Boulder. At the same time as the surface effort was going on, an instrumented light aircraft conducted transects over the Basin collecting air samples mostly in the boundary layer and measuring in situ the following species CH4, CO2, NO2, O3. We will present some of the data collected by the Mobile Lab and the aircraft and discuss analysis results.

  11. Evaluation and Prediction of Henry’s Law Constants and Aqueous Solubilities for Solvents and Hydrocarbon Fuel Components. Volume 1. Technical Discussion

    DTIC Science & Technology

    1987-09-01

    spectrum cap with a Teflonýliner facing toward the bottle headspace. These liners are used only once to prevent adsorption of test compound into the...used to predict carbon adsorption of contaminants, and the air or steam stripping behavior for a given organic. For highly soluble materials these data...first of these stems from the organic-solute losses due to adsorption of the solute on the flask walls or to evaporation. This quantity is somewhat

  12. A case of death of the driver due to environmental asphyxia by liquid nitrogen leakage in the cabin of the car during a road accident

    PubMed

    Raczkowska, Zuzanna; Samojłowicz, Dorota

    2013-01-01

    Nitrogen causes environmental asphyxia by displacing oxygen in the air leading to death. The study presents a case of a death of a driver death who was transporting flasks with liquid nitrogen that depressurized during an accident. The mechanism and cause of death were determined based on the result of the autopsy and histopathologic examination. The authors emphasize the relevance of accident scene inspection during establishing the cause of death in similar cases.

  13. A powerless on-the-spot detection protocol for transgenic crops within 30 min, from leaf sampling up to results.

    PubMed

    Wang, Liu; Wang, Rui; Yu, Yonghua; Zhang, Fang; Wang, Xiaofu; Ying, Yibin; Wu, Jian; Xu, Junfeng

    2016-01-01

    The requirement of power-dependent instruments or excessive operation time usually restricts current nucleic acid amplification methods from being used for detection of transgenic crops in the field. In this paper, an easy and rapid detection method which requires no electricity supply has been developed. The time-consuming process of nucleic acid purification is omitted in this method. DNA solution obtained from leaves with 0.5 M sodium hydroxide (NaOH) can be used for loop-mediated isothermal amplification (LAMP) only after simple dilution. Traditional instruments like a polymerase chain reaction (PCR) amplifier and water bath used for DNA amplification are abandoned. Three kinds of dewar flasks were tested and it turned out that the common dewar flask was the best. Combined with visual detection of LAMP amplicons by phosphate (Pi)-induced coloration reaction, the whole process of detection of transgenic crops via genetically pure material (leaf material of one plant) could be accomplished within 30 min. The feasibility of this method was also verified by analysis of practical samples.

  14. Effect of Oxygen-Supply Rates on Growth of Escherichia coli

    PubMed Central

    McDaniel, L. E.; Bailey, E. G.; Zimmerli, A.

    1965-01-01

    The effect of oxygen-supply rates on bacterial growth was studied in commercially available unbaffled and baffled flasks with the use of Escherichia coli in a synthetic medium as a test system. The amount of growth obtained depended on the oxygen-supply rate. Based on oxygen-absorption rates (OAR) measured by the rate of sulfite oxidation, equal OAR values in different types of flasks did not give equal amounts of growth. However, growth was essentially equal at the equal sulfite-oxidation rates when these were determined in the presence of killed whole cultures. Specific growth rates were reduced only at oxygen-supply rates much lower than those at which the total amount of growth was reduced. For the physical set-up used in this work and with the biological system employed, Bellco 598 flasks and flasks fitted with Biotech stainless-steel baffles gave satisfactory results at workable broth volumes; unbaffled and Bellco 600 flasks did not. PMID:14264837

  15. Mercury - Its occurrence and economic trends

    USGS Publications Warehouse

    Bailey, Edgar H.; Smith, Roscoe M.

    1964-01-01

    price will be a predictable increase in production. If the price averages $300 a flask for 1 year or more, annual production may increase to a rate of 30,000-35,000 flasks in 1966 or 1967. If the price averages $400 a flask, production may increase to 45,000-50,000 flasks a year after a timelag of two or three years. New ore bodies would have to be found however, to attain these rates of production, and the mining of lower grade ores would be needed to sustain them for more than a few years. By 1966 the U.S. economy will require at least 67 000 flasks, and the domestic demand for mercury thereafter will continue to increase. The probability that domestic mines will continue to supply a fourth or more of the domestic consumption is dependent upon the price of mercury for the next few years. The outlook for the long-term supply is reassuring, but it is dependent, not only upon price, but upon continued progress in new techniques of discovery.

  16. Sensor Access to the Cellular Microenvironment Using the Sensing Cell Culture Flask.

    PubMed

    Kieninger, Jochen; Tamari, Yaara; Enderle, Barbara; Jobst, Gerhard; Sandvik, Joe A; Pettersen, Erik O; Urban, Gerald A

    2018-04-26

    The Sensing Cell Culture Flask (SCCF) is a cell culture monitoring system accessing the cellular microenvironment in 2D cell culture using electrochemical microsensors. The system is based on microfabricated sensor chips embedded in standard cell culture flasks. Ideally, the sensor chips could be equipped with any electrochemical sensor. Its transparency allows optical inspection of the cells during measurement. The surface of the sensor chip is in-plane with the flask surface allowing undisturbed cell growth on the sensor chip. A custom developed rack system allows easy usage of multiple flasks in parallel within an incubator. The presented data demonstrates the application of the SCCF with brain tumor (T98G) and breast cancer (T-47D) cells. Amperometric oxygen sensors were used to monitor cellular respiration with different incubation conditions. Cellular acidification was accessed with potentiometric pH sensors using electrodeposited iridium oxide films. The system itself provides the foundation for electrochemical monitoring systems in 3D cell culture.

  17. A Pilot Study to Evaluate California's Fossil Fuel CO2 Emissions Using Atmospheric Observations

    NASA Astrophysics Data System (ADS)

    Graven, H. D.; Fischer, M. L.; Lueker, T.; Guilderson, T.; Brophy, K. J.; Keeling, R. F.; Arnold, T.; Bambha, R.; Callahan, W.; Campbell, J. E.; Cui, X.; Frankenberg, C.; Hsu, Y.; Iraci, L. T.; Jeong, S.; Kim, J.; LaFranchi, B. W.; Lehman, S.; Manning, A.; Michelsen, H. A.; Miller, J. B.; Newman, S.; Paplawsky, B.; Parazoo, N.; Sloop, C.; Walker, S.; Whelan, M.; Wunch, D.

    2016-12-01

    Atmospheric CO2 concentration is influenced by human activities and by natural exchanges. Studies of CO2 fluxes using atmospheric CO2 measurements typically focus on natural exchanges and assume that CO2 emissions by fossil fuel combustion and cement production are well-known from inventory estimates. However, atmospheric observation-based or "top-down" studies could potentially provide independent methods for evaluating fossil fuel CO2 emissions, in support of policies to reduce greenhouse gas emissions and mitigate climate change. Observation-based estimates of fossil fuel-derived CO2 may also improve estimates of biospheric CO2 exchange, which could help to characterize carbon storage and climate change mitigation by terrestrial ecosystems. We have been developing a top-down framework for estimating fossil fuel CO2 emissions in California that uses atmospheric observations and modeling. California is implementing the "Global Warming Solutions Act of 2006" to reduce total greenhouse gas emissions to 1990 levels by 2020, and it has a diverse array of ecosystems that may serve as CO2 sources or sinks. We performed three month-long field campaigns in different seasons in 2014-15 to collect flask samples from a state-wide network of 10 towers. Using measurements of radiocarbon in CO2, we estimate the fossil fuel-derived CO2 present in the flask samples, relative to marine background air observed at coastal sites. Radiocarbon (14C) is not present in fossil fuel-derived CO2 because of radioactive decay over millions of years, so fossil fuel emissions cause a measurable decrease in the 14C/C ratio in atmospheric CO2. We compare the observations of fossil fuel-derived CO2 to simulations based on atmospheric modeling and published fossil fuel flux estimates, and adjust the fossil fuel flux estimates in a statistical inversion that takes account of several uncertainties. We will present the results of the top-down technique to estimate fossil fuel emissions for our field campaigns in California, and we will give an outlook for future development of the technique in California.

  18. Observation of development of breast cancer cell lines in real time by fluorescence microscopy under simulated microgravity

    NASA Astrophysics Data System (ADS)

    Lavan, David; Valdivia-Silva, Julio E.; Sanabria, Gabriela; Orihuela, Diego; Suarez, Juan; Quispe, Marco; Chuchon, Mariano; Martin, David; Maroto, Marcos; Egea, Javier

    2016-07-01

    This project consist in the implementation of a fluorescence microscope for the in real time monitoring of biological labeled samples by several fluorophores in microgravity conditions keeping the temperature, humidity, and (CO)2 controlled by an electronic platform. The system (fluorescence microscope and incubator) is integrated to a microgravity simulator machine which was presented on the "30th Annual American Society for Gravitation and Space Research Meeting" October 2014 in Pasadena, CA, USA. Currently, we have the microgravity machine biologically validated by genetic expression studies in pupal stage of Drosophila melanogaster. The fluorescence microscope has a platform designed to hold a culture flask, and a fluorescence camera (Leica DFC3000 G) connected to an optical system (Fluorescence Light source Leica EL6000, optic fiber, fiber adapter, and fluorescence filter) in order to take images in real time. The mechanical system of the fluorescence microsc ope is designed to allow the displacement of the fluorescence camera through a parallel plane to the culture flask's plane and also the movement of the platform through a perpendicular axis to the culture flask in order to focus the samples to the optical system. The mechanical system is propelled by four DC moto-reductors with encoder (A-max 26 Maxon motor, GP 32S screw and MR encoder) that generate displacements in the order of micrometers. The angular position control of the DC motoreductor's shaft of all the DC moto-reductors is done by PWM signals based on the interpretation of the signals provided by the encoders during the movement. The system is remotely operated by a graphic interface installed on a personal computer or any mobile device (smartphone, laptop or tablet) by using the internet. Acknowledgments: Grant of INNOVATE PERU (Formerly FINCYT)

  19. Beta-glucan production by Botryosphaeria rhodina in different bench-top bioreactors.

    PubMed

    Selbmann, L; Crognale, S; Petruccioli, M

    2004-01-01

    Evaluation of the technical feasibility of transferring beta-glucan production by Botryosphaeria rhodina DABAC-P82 from shaken flasks to bench-top bioreactors. Three different bioreactors were used: 3 l stirred tank reactor (STR-1) equipped with two different six-blade turbines; STR as above but equipped with a three-blade marine propeller plus draft-tube (STR-2); 2 l air-lift column reactor (ALR) equipped with an external loop. STR-1, tested at three different stirrer speeds (300, 500 and 700 rev min(-1)) appeared to be less suitable for beta-glucan production by the fungus, being maximum production (19.4 g l(-1)), productivity (0.42 g l(-1) h(-1)) and yield (0.48 g g(-1) of glucose consumed) markedly lower than those obtained in shaken culture (29.7 g l(-1), 1.23 g l(-1) h(-1) and 0.61 g g(-1), respectively). Better performances were obtained with both STR-2 and ALR. With the latter, in particular, the increase of production was accompanied by reduced fermentation time (25.7 g l(-1) after only 22 h); productivity and yield were highest (1.17 g l(-1) h(-1) and 0.62 g g(-1) of glucose consumed, respectively). Using an air-lift reactor with external loop, the scaling up from shaken flasks to bench-top bioreactor of the beta-glucan production by B. rhodina DABAC-P82 is technically feasible. Although culture conditions are still to be optimized, the results obtained using the ARL are highly promising.

  20. The Drivers of the CH4 Seasonal Cycle in the Arctic and What Long-Term Observations of CH4 Imply About Trends in Arctic CH4 Fluxes

    NASA Astrophysics Data System (ADS)

    Sweeney, C.; Karion, A.; Bruhwiler, L.; Miller, J. B.; Wofsy, S. C.; Miller, C. E.; Chang, R. Y.; Dlugokencky, E. J.; Daube, B.; Pittman, J. V.; Dinardo, S. J.

    2012-12-01

    The large seasonal change in the atmospheric column for CH4 in the Arctic is driven by two dominant processes: transport of CH4 from low latitudes and surface emissions throughout the Arctic region. The NOAA ESRL Carbon Cycle Group Aircraft Program along with the NASA funded Carbon in Arctic Reservoirs Vulnerability Experiment (CARVE) have initiated an effort to better understand the factors controlling the seasonal changes in the mole fraction of CH4 in the Arctic with a multi-scale aircraft observing network in Alaska. The backbone of this network is multi-species flask sampling from 500 to 8000 masl that has been conducted every two weeks for the last 10 years over Poker Flat, AK. In addition regular profiles at the interior Alaska site at Poker Flat, NOAA has teamed up with the United States Coast Guard to make profiling flights with continuous observations of CO2, CO, CH4 and Ozone between Kodiak and Barrow every 2 weeks. More recently, CARVE has significantly added to this observational network with targeted flights focused on exploring the variability of CO2, CH4 and CO in the boundary layer both in the interior and the North Slope regions of Alaska. Taken together with the profiling of HIAPER Pole-to-Pole Observations (HIPPO), ground sites at Barrow and a new CARVE interior Alaska surface site just north of Fairbanks, AK, we now have the ability to investigate the full evolution of the seasonal cycle in the Arctic using both the multi-scale sampling offered by the different aircraft platforms as well as the multi-species sampling offered by in-situ and flask sampling. The flasks also provide a valuable tie-point between different platforms so that spatial and temporal gradients can be properly interpreted. In the context of the seasonal cycle observed by the aircraft platforms we will look at long term ground observations over the last 20 years to assess changes in Arctic CH4 emissions which have occurred as a result of 0.6C/decade changes in mean surface temperatures.

  1. Simultaneous assimilation of AIRS and GOSAT CO2 observations with Ensemble Kalman filter

    NASA Astrophysics Data System (ADS)

    Liu, J.; Kalnay, E.; Fung, I.; Kang, J.

    2012-12-01

    Lack of CO2 vertical information could lead to bias in the surface CO2 flux estimation (Stephens et al., 2007). Liu et al. (2012) showed that assimilating AIRS CO2 observations, which are sensitive to middle to upper troposphere CO2, improves CO2 concentration, especially in the middle to upper troposphere. GOSAT is sensitive to CO2 over the whole column, but the spatial coverage is sparser than AIRS. In this study, we assimilate AIRS and GOSAT CO2 observations simultaneously along with surface flask CO2 observations and meteorology observations with Ensemble Kalman filter (EnKF) to constrain CO2 vertical profiles simulated by NCAR carbon-climate model. We will show the impact of assimilating AIRS and GOSAT CO2 on the CO2 vertical gradient, seasonal cycle and spatial gradient by assimilating only GOSAT or AIRS and comparing to the control experiment. The quality of CO2 analysis will be examined by validating against independent CO2 aircraft observations, and analyzing the relationship between CO2 analysis fields and major circulation, such as Madden Julian Oscillation. We will also discuss the deficiencies of the observation network in understanding the carbon cycle.

  2. Synthesis of Microporous Materials and Their VSC Adsorption Properties

    NASA Astrophysics Data System (ADS)

    Yokogawa, Y.; Morikawa, H.; Sakanishi, M.; Utaka, H.; Nakamura, A.; Kishida, I.

    2011-10-01

    Oral malodor is caused by volatile sulfur compounds (VSC) such as hydrogen sulfide (H2S), methyl mercaptan and dimethyl sulfide produced in mouth. VSC induces permeability of mucous membrane and oral malodor formation. Thus, the adsorbent which highly adsorbs VSC should be useful for health in mouth and may prevent teeth from decaying. The microporous material, hydrotalcite, was synthesized by a wet method, and the H2S adsorption was studied. The samples, identified by powder X-ray diffraction method, were put into glass flask filled with H2S gas. The initial concentration of H2S was 30 ppm. The change in concentrations of H2S was measured at rt, and the amount of H2S absorbed on the hydrotalcite for 24 h was 300 micro L/g. The samples were taken out from the above glass flask and put into a pyrolysis plant attached to gas chromatography-mass spectrometry to determine the amount of H2S desorbed from samples. Only 3 % of H2S was desorbed when heated at 500 °C. H2S in water was also found to adsorb into hydrotalcite, which was confirmed by the headspace gas chromatography with flame photometric detector. The hydrotalcite material should be expected to be an adsorbent material, useful for health in mouth.

  3. Using box models to quantify zonal distributions and emissions of halocarbons in the background atmosphere.

    NASA Astrophysics Data System (ADS)

    Elkins, J. W.; Nance, J. D.; Dutton, G. S.; Montzka, S. A.; Hall, B. D.; Miller, B.; Butler, J. H.; Mondeel, D. J.; Siso, C.; Moore, F. L.; Hintsa, E. J.; Wofsy, S. C.; Rigby, M. L.

    2015-12-01

    The Halocarbons and other Atmospheric Trace Species (HATS) of NOAA's Global Monitoring Division started measurements of the major chlorofluorocarbons and nitrous oxide in 1977 from flask samples collected at five remote sites around the world. Our program has expanded to over 40 compounds at twelve sites, which includes six in situ instruments and twelve flask sites. The Montreal Protocol for Substances that Deplete the Ozone Layer and its subsequent amendments has helped to decrease the concentrations of many of the ozone depleting compounds in the atmosphere. Our goal is to provide zonal emission estimates for these trace gases from multi-box models and their estimated atmospheric lifetimes in this presentation and make the emission values available on our web site. We plan to use our airborne measurements to calibrate the exchange times between the boxes for 5-box and 12-box models using sulfur hexafluoride where emissions are better understood.

  4. Degradation and depolymerization of plastic waste by local bacterial isolates and bubble column reactor

    NASA Astrophysics Data System (ADS)

    Hussein, Amal A.; Alzuhairi, Mohammed; Aljanabi, Noor H.

    2018-05-01

    Accumulation of plastics, especially Polyethylene terephthalate (PET), is an ever increasing ecological threat due to its excessive usage in everyday human life. Nowadays, there are many methods to get rid of plastic wastes including burning, recycling and burying. However, these methods are not very active since their long period, anaerobic conditions that increase the rate of toxic materials released into the environment. This work aims to study the biological degradation of PET microorganism isolated from soil sample. Thirty eight (38) bacterial isolates were isolated from ten soil and plastic waste sample collected from four different waste disposal sites in Baghdad city during different periods between December 2016 and March 2017. Isolation was performed using enrichment culture method (flasks method) by culturing the soil samples in flasks with MSM medium where there is no carbon source only PET. Results showed that Al-Za'farania sample gave a higher number of isolates (13 isolates), while other samples gave less number of isolates. Screening was performed depending on their ability to grow in liquid MSM which contains PET powder and pieces and change the color of the PET-emulsified liquid medium as well as their ability to form the clear zone on PET-MSM agar. The results showed that NH-D-1 isolate has the higher ability to degrade DPET and PET pieces. According to morphological, biochemical characterization and Vitek-2 technique, the most active isolate was identified as Acinetobacter baumannii.

  5. Scale-up from shake flasks to bioreactor, based on power input and Streptomyces lividans morphology, for the production of recombinant APA (45/47 kDa protein) from Mycobacterium tuberculosis.

    PubMed

    Gamboa-Suasnavart, Ramsés A; Marín-Palacio, Luz D; Martínez-Sotelo, José A; Espitia, Clara; Servín-González, Luis; Valdez-Cruz, Norma A; Trujillo-Roldán, Mauricio A

    2013-08-01

    Culture conditions in shake flasks affect filamentous Streptomyces lividans morphology, as well the productivity and O-mannosylation of recombinant Ala-Pro-rich O-glycoprotein (known as the 45/47 kDa or APA antigen) from Mycobacterium tuberculosis. In order to scale up from previous reported shake flasks to bioreactor, data from the literature on the effect of agitation on morphology of Streptomyces strains were used to obtain gassed volumetric power input values that can be used to obtain a morphology of S. lividans in bioreactor similar to the morphology previously reported in coiled/baffled shake flasks by our group. Morphology of S. lividans was successfully scaled-up, obtaining similar mycelial sizes in both scales with diameters of 0.21 ± 0.09 mm in baffled and coiled shake flasks, and 0.15 ± 0.01 mm in the bioreactor. Moreover, the specific growth rate was successfully scaled up (0.09 ± 0.02 and 0.12 ± 0.01 h(-1), for bioreactors and flasks, respectively), and the recombinant protein productivity measured by densitometry, as well. More interestingly, the quality of the recombinant glycoprotein measured as the amount of mannoses attached to the C-terminal of APA was also scaled- up; with up to five mannose residues in cultures carried out in shake flasks; and six in the bioreactor. However, final biomass concentration was not similar, indicating that although the process can be scaled-up using the power input, others factors like oxygen transfer rate, tip speed or energy dissipation/circulation function can be an influence on bacterial metabolism.

  6. Quantifying the Erlenmeyer flask deformity

    PubMed Central

    Carter, A; Rajan, P S; Deegan, P; Cox, T M; Bearcroft, P

    2012-01-01

    Objective Erlenmeyer flask deformity is a common radiological finding in patients with Gaucher′s disease; however, no definition of this deformity exists and the reported prevalence of the deformity varies widely. To devise an easily applied definition of this deformity, we investigated a cohort of knee radiographs in which there was consensus between three experienced radiologists as to the presence or absence of Erlenmeyer flask morphology. Methods Using the presence or absence of Erlenmeyer flask morphology as a benchmark, we measured the diameter of the femur at the level of the physeal scar and serially at defined intervals along the metadiaphysis. Results A measured ratio in excess of 0.57 between the diameter of the femoral shaft 4 cm from the physis to the diameter of the physeal baseline itself on a frontal radiograph of the knee predicted the Erlenmeyer flask deformity with 95.6% sensitivity and 100% specificity in our series of 43 independently diagnosed adults with Gaucher′s disease. Application of this method to the distal femur detected the Erlenmeyer flask deformity reproducibly and was simple to carry out. Conclusion Unlike diagnostic assignments based on subjective review, our simple procedure for identifying the modelling deformity is based on robust quantitative measurement: it should facilitate comparative studies between different groups of patients, and may allow more rigorous exploration of the pathogenesis of the complex osseous manifestations of Gaucher′s disease to be undertaken. PMID:22010032

  7. Delivery of Epinephrine in the Vapor Phase for the Treatment of Croup.

    PubMed

    Leung, Kitty; Newth, Christopher J L; Hotz, Justin C; O'Brien, Kevin C; Fink, James B; Coates, Allan L

    2016-04-01

    The Vapotherm system delivers high humidity to the airway of patients by using semipermeable tubules where heated liquid water is in contact with air. The humidified air is conducted to the patient via a heated tube. Preliminary clinical observations in infants with croup suggested that epinephrine added to the water supplying the humidity was delivered successfully in the vapor phase. The purpose of this study was to evaluate the efficiency of the delivery of epinephrine in the vapor phase and to develop the feasibility criteria for a clinical pilot study. Thirty milligrams of epinephrine in a 1-L bag of sterile water was used as the humidification source for a Vapotherm 2000i. The output of the heated circuit was condensed and collected into a small Erlenmeyer flask via a metal coil while the whole collection system was submerged in an ice slurry to maintain the outflow temperature from the flask between 0°C and 2°C. The in vitro system was tested at 40°C with flows of 5, 10, and 15 L/min and L-epinephrine concentrations of 15, 30, and 60 mg/L. Each test was duplicated at each of the six conditions. Academic children's hospital research laboratory. None. None. The system recovered more than 90% of the water vapor from the fully saturated air at 40°C. The epinephrine concentration recovery quantified by ultraviolet-visible spectrophotometry was 23.9% (27.5-20.4%) (mean and range) of the initial concentration. At flows of 5, 10, and 15 L/min, the delivery of epinephrine would be 1.8, 3.6, and 4.2 μg/min, respectively, which is in the therapeutic range used for parenteral infusion in young children. The Vapotherm system can be used to deliver epinephrine in pharmacological doses to the respiratory system as a vapor and thus as an alternative to droplets by conventional nebulization.

  8. Non-invasive and non-destructive measurements of confluence in cultured adherent cell lines.

    PubMed

    Busschots, Steven; O'Toole, Sharon; O'Leary, John J; Stordal, Britta

    2015-01-01

    Many protocols used for measuring the growth of adherent monolayer cells in vitro are invasive, destructive and do not allow for the continued, undisturbed growth of cells within flasks. Protocols often use indirect methods for measuring proliferation. Microscopy techniques can analyse cell proliferation in a non-invasive or non-destructive manner but often use expensive equipment and software algorithms. In this method images of cells within flasks are captured by photographing under a standard inverted phase contract light microscope using a digital camera with a camera lens adaptor. Images are analysed for confluence using ImageJ freeware resulting in a measure of confluence known as an Area Fraction (AF) output. An example of the AF method in use on OVCAR8 and UPN251 cell lines is included. •Measurements of confluence from growing adherent cell lines in cell culture flasks is obtained in a non-invasive, non-destructive, label-free manner.•The technique is quick, affordable and eliminates sample manipulation.•The technique provides an objective, consistent measure of when cells reach confluence and is highly correlated to manual counting with a haemocytometer. The average correlation co-efficient from a Spearman correlation (n = 3) was 0.99 ± 0.008 for OVCAR8 (p = 0.01) and 0.99 ± 0.01 for UPN251 (p = 0.01) cell lines.

  9. Evaluation of an Immobilized Cell Bioreactor for Degradation of Meta- and Para-Nitrobenzoate

    DTIC Science & Technology

    1994-01-18

    AFB IWTP. 4 Shake flask tests and continuous flow, bench-scale bioreactor tests were conducted using EDA or spent CLEPO 204 as the substrate. It was...found that the shake flask cultures completely degraded EDA when it was the sole substrate. However, using spent CLEPO 204 as the substrate caused a...microorganisms isolated, Kelly 4. Erlenmeyer flasks (250 mL) were used in studies to determine the maximal growth rate of Kelly 4 at 30" C in SMSB

  10. Blood transport method for chromosome analysis of residents living near Semipalatinsk nuclear test site.

    PubMed

    Rodzi, Mohd; Ihda, Shozo; Yokozeki, Masako; Takeichi, Nobuo; Tanaka, Kimio; Hoshi, Masaharu

    2009-12-01

    A study was conducted to compare the storage conditions and transportation period for blood samples collected from residents living in areas near the Semipalatinsk nuclear test site (SNTS). Experiments were performed to simulate storage and shipping environments. Phytohaemagglutinin (PHA)-stimulated blood was stored in 15-ml tubes (condition A: current transport method) in the absence or in 50-ml flasks (condition B: previous transport method) in the presence of RPMI-1640 and 20% fetal bovine serum (FBS). Samples were kept refrigerated at 4 degrees C and cell viability was assessed after 3, 8, 12 and 14 days of storage. RPMI-1640, 20% FBS and further PHA were added to blood samples under condition A in 50-ml flasks for culture. Whole-blood samples under condition B were directly incubated without further sub-culturing process, neither media nor PHA were added, to adopt a similar protocol to that employed in the previous transport method. Samples in condition A and condition B were incubated for 48 hr at 37 degrees C and their mitotic index was determined. The results showed that viable lymphocytes were consistent in both storage conditions but the mitotic index was higher in condition A than in condition B. Although further confirmation studies have to be carried out, previous chromosomal studies and the present experiment have shown that PHA-stimulated blood could be stored without culture medium for up to 8 days under condition A. The present results will be useful for cytogenetic analysis of blood samples that have been transported long distances wherever a radiation accident has occurred.

  11. Formation of three-dimensional cell/polymer constructs for bone tissue engineering in a spinner flask and a rotating wall vessel bioreactor

    NASA Technical Reports Server (NTRS)

    Sikavitsas, Vassilios I.; Bancroft, Gregory N.; Mikos, Antonios G.; McIntire, L. V. (Principal Investigator)

    2002-01-01

    The aim of this study is to investigate the effect of the cell culture conditions of three-dimensional polymer scaffolds seeded with rat marrow stromal cells (MSCs) cultured in different bioreactors concerning the ability of these cells to proliferate, differentiate towards the osteoblastic lineage, and generate mineralized extracellular matrix. MSCs harvested from male Sprague-Dawley rats were culture expanded, seeded on three-dimensional porous 75:25 poly(D,L-lactic-co-glycolic acid) biodegradable scaffolds, and cultured for 21 days under static conditions or in two model bioreactors (a spinner flask and a rotating wall vessel) that enhance mixing of the media and provide better nutrient transport to the seeded cells. The spinner flask culture demonstrated a 60% enhanced proliferation at the end of the first week when compared to static culture. On day 14, all cell/polymer constructs exhibited their maximum alkaline phosphatase activity (AP). Cell/polymer constructs cultured in the spinner flask had 2.4 times higher AP activity than constructs cultured under static conditions on day 14. The total osteocalcin (OC) secretion in the spinner flask culture was 3.5 times higher than the static culture, with a peak OC secretion occurring on day 18. No considerable AP activity and OC secretion were detected in the rotating wall vessel culture throughout the 21-day culture period. The spinner flask culture had the highest calcium content at day 14. On day 21, the calcium deposition in the spinner flask culture was 6.6 times higher than the static cultured constructs and over 30 times higher than the rotating wall vessel culture. Histological sections showed concentration of cells and mineralization at the exterior of the foams at day 21. This phenomenon may arise from the potential existence of nutrient concentration gradients at the interior of the scaffolds. The better mixing provided in the spinner flask, external to the outer surface of the scaffolds, may explain the accelerated proliferation and differentiation of marrow stromal osteoblasts, and the localization of the enhanced mineralization on the external surface of the scaffolds. Copyright 2002 Wiley Periodicals, Inc.

  12. Micro system comprising 96 micro valves on a titer plate

    NASA Astrophysics Data System (ADS)

    Krabbe, S.; Flitsch, D.; Büchs, J.; Schomburg, W. K.

    2016-10-01

    A system of 96 micro valves has been developed and mounted on top of a 48-well micro titer plate providing two valves for each well controlling its air inlet and outlet. Testing of the valve system showed that all valves are working and are opened and closed reliably. A pneumatic system is switching inlet and outlet valves independently of each other. The geometry of the feed channels ensures an equal air flow through all wells, when the valves are open. Between the micro valves, one optical fibre was inserted through the lid of each well allowing measuring the oxygen partial pressure in the enclosed air volume by fluorescence sensor spots. Escherichia coli bacteria were grown inside the wells and their metabolism was observed by the oxygen partial pressure change due to respiration. In all 48 wells, the same oxygen transfer rate was observed within an averaged standard deviation of 1 mmol/L/h. The oxygen transfer rate differences compared to a macroscopic standard shake flask system were overall compatible within their uncertainties.

  13. 40 CFR Appendix A to Part 80 - Test for the Determination of Phosphorus in Gasoline

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Specification for Filter Paper for Use in Chemical Analysis. 3. Summary of method. 3.1 Organic matter in the...) during the entire period of sample heating. Note 1: If the temperature of the hot water bath drops below... 100-ml volumetric flasks submerged to the mark in ice water. 4.4 Filter Paper, for quantitative...

  14. 40 CFR Appendix A to Part 80 - Test for the Determination of Phosphorus in Gasoline

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Specification for Filter Paper for Use in Chemical Analysis. 3. Summary of method. 3.1 Organic matter in the...) during the entire period of sample heating. Note 1: If the temperature of the hot water bath drops below... 100-ml volumetric flasks submerged to the mark in ice water. 4.4 Filter Paper, for quantitative...

  15. 40 CFR Appendix A to Part 80 - Test for the Determination of Phosphorus in Gasoline

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Specification for Filter Paper for Use in Chemical Analysis. 3. Summary of method. 3.1 Organic matter in the...) during the entire period of sample heating. Note 1: If the temperature of the hot water bath drops below... 100-ml volumetric flasks submerged to the mark in ice water. 4.4 Filter Paper, for quantitative...

  16. 21 CFR 172.250 - Petroleum naphtha.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... at room temperature, with intermittent swirling. At the end of this time, disconnect the flask and.... Dissolve the crystals in the flask with about 25 milliliters of distilled water and pour this also into the...

  17. 21 CFR 172.250 - Petroleum naphtha.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... at room temperature, with intermittent swirling. At the end of this time, disconnect the flask and.... Dissolve the crystals in the flask with about 25 milliliters of distilled water and pour this also into the...

  18. 21 CFR 172.250 - Petroleum naphtha.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    .... At the end of this time, disconnect the flask and evaporate the methyl alcohol on the steam bath... transfer the isooctane extract to a 250-milliliter separatory funnel. Dissolve the crystals in the flask...

  19. 21 CFR 172.250 - Petroleum naphtha.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... at room temperature, with intermittent swirling. At the end of this time, disconnect the flask and.... Dissolve the crystals in the flask with about 25 milliliters of distilled water and pour this also into the...

  20. 21 CFR 172.250 - Petroleum naphtha.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... at room temperature, with intermittent swirling. At the end of this time, disconnect the flask and.... Dissolve the crystals in the flask with about 25 milliliters of distilled water and pour this also into the...

  1. A comparison of the effects of two methods of acclimation of aerobic biodegradability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Watson, H.M.

    1993-11-01

    The acclimation or adaptation of microorganisms to organic chemicals is an important factor influencing both the rate and the extent of biodegradation. In this study two acclimation procedures were evaluated in terms of their effectiveness in enhancing biodegradation, their relative ease of use in the laboratory, and the implications for biodegradability testing. In the single-flask procedure, microorganisms were acclimated for 2 to 7 d in a single acclimation flask at constant or increasing concentrations of the test chemical without transfer of microorganisms. In the second procedure, the enrichment procedure, microorganisms were acclimated in a series of flasks over a 21-dmore » period by making adaptive transfers to increasing concentrations of the test chemical. Acclimated microorganisms from each procedure were used as the source of inoculum for subsequent biodegradation tests in which carbon dioxide evolution was measured. Six chemicals were tested: quinoline, p-nitrophenol, N-methylaniline, N,N-dimethylaniline, acrylonitrile, and 2,2,4-trimethyl-1,3-pentanediol monoisobutyrate. Microorganisms acclimated in the single-flask procedure were much more effective than those acclimated in the enrichment procedure in degrading the test chemicals. The single-flask procedure is more convenient to use, and it permits monitoring of the time needed for acclimation. The results from these studies have implications for the methodology used in biodegradation test systems and suggest caution before adopting a multiple-flask, enrichment acclimation procedure before the performance of standardized tests for aerobic biodegradability.« less

  2. Global and regional emissions estimates for N2O

    NASA Astrophysics Data System (ADS)

    Saikawa, E.; Prinn, R. G.; Dlugokencky, E.; Ishijima, K.; Dutton, G. S.; Hall, B. D.; Langenfelds, R.; Tohjima, Y.; Machida, T.; Manizza, M.; Rigby, M.; O'Doherty, S.; Patra, P. K.; Harth, C. M.; Weiss, R. F.; Krummel, P. B.; van der Schoot, M.; Fraser, P. J.; Steele, L. P.; Aoki, S.; Nakazawa, T.; Elkins, J. W.

    2014-05-01

    We present a comprehensive estimate of nitrous oxide (N2O) emissions using observations and models from 1995 to 2008. High-frequency records of tropospheric N2O are available from measurements at Cape Grim, Tasmania; Cape Matatula, American Samoa; Ragged Point, Barbados; Mace Head, Ireland; and at Trinidad Head, California using the Advanced Global Atmospheric Gases Experiment (AGAGE) instrumentation and calibrations. The Global Monitoring Division of the National Oceanic and Atmospheric Administration/Earth System Research Laboratory (NOAA/ESRL) has also collected discrete air samples in flasks and in situ measurements from remote sites across the globe and analyzed them for a suite of species including N2O. In addition to these major networks, we include in situ and aircraft measurements from the National Institute of Environmental Studies (NIES) and flask measurements from the Tohoku University and Commonwealth Scientific and Industrial Research Organization (CSIRO) networks. All measurements show increasing atmospheric mole fractions of N2O, with a varying growth rate of 0.1-0.7% per year, resulting in a 7.4% increase in the background atmospheric mole fraction between 1979 and 2011. Using existing emission inventories as well as bottom-up process modeling results, we first create globally gridded a priori N2O emissions over the 37 years since 1975. We then use the three-dimensional chemical transport model, Model for Ozone and Related Chemical Tracers version 4 (MOZART v4), and a Bayesian inverse method to estimate global as well as regional annual emissions for five source sectors from 13 regions in the world. This is the first time that all of these measurements from multiple networks have been combined to determine emissions. Our inversion indicates that global and regional N2O emissions have an increasing trend between 1995 and 2008. Despite large uncertainties, a significant increase is seen from the Asian agricultural sector in recent years, most likely due to an increase in the use of nitrogenous fertilizers, as has been suggested by previous studies.

  3. Atmospheric measurement of point source fossil fuel CO2 emissions

    NASA Astrophysics Data System (ADS)

    Turnbull, J. C.; Keller, E. D.; Baisden, W. T.; Brailsford, G.; Bromley, T.; Norris, M.; Zondervan, A.

    2013-11-01

    We use the Kapuni Gas Treatment Plant to examine methodologies for atmospheric monitoring of point source fossil fuel CO2 (CO2ff) emissions. The Kapuni plant, located in rural New Zealand, removes CO2 from locally extracted natural gas and vents that CO2 to the atmosphere, at a rate of ~0.1 Tg carbon per year. The plant is located in a rural dairy farming area, with no other significant CO2ff sources nearby, but large, diurnally varying, biospheric CO2 fluxes from the surrounding highly productive agricultural grassland. We made flask measurements of CO2 and 14CO2 (from which we derive the CO2ff component) and in situ measurements of CO2 downwind of the Kapuni plant, using a Helikite to sample transects across the emission plume from the surface up to 100 m a.g.l. We also determined the surface CO2ff content averaged over several weeks from the 14CO2 content of grass samples collected from the surrounding area. We use the WindTrax plume dispersion model to compare the atmospheric observations with the emissions reported by the Kapuni plant, and to determine how well atmospheric measurements can constrain the emissions. The model has difficulty accurately capturing the fluctuations and short-term variability in the Helikite samples, but does quite well in representing the observed CO2ff in 15 min averaged surface flask samples and in ~1 week integrated CO2ff averages from grass samples. In this pilot study, we found that using grass samples, the modeled and observed CO2ff emissions averaged over one week agreed to within 30%. The results imply that greater verification accuracy may be achieved by including more detailed meteorological observations and refining 14CO2 sampling strategies.

  4. Atmospheric measurement of point source fossil CO2 emissions

    NASA Astrophysics Data System (ADS)

    Turnbull, J. C.; Keller, E. D.; Baisden, T.; Brailsford, G.; Bromley, T.; Norris, M.; Zondervan, A.

    2014-05-01

    We use the Kapuni Gas Treatment Plant to examine methodologies for atmospheric monitoring of point source fossil fuel CO2 (CO2ff) emissions. The Kapuni plant, located in rural New Zealand, removes CO2 from locally extracted natural gas and vents that CO2 to the atmosphere, at a rate of ~0.1 Tg carbon per year. The plant is located in a rural dairy farming area, with no other significant CO2ff sources nearby, but large, diurnally varying, biospheric CO2 fluxes from the surrounding highly productive agricultural grassland. We made flask measurements of CO2 and 14CO2 (from which we derive the CO2ff component) and in situ measurements of CO2 downwind of the Kapuni plant, using a Helikite to sample transects across the emission plume from the surface up to 100 m above ground level. We also determined the surface CO2ff content averaged over several weeks from the 14C content of grass samples collected from the surrounding area. We use the WindTrax plume dispersion model to compare the atmospheric observations with the emissions reported by the Kapuni plant, and to determine how well atmospheric measurements can constrain the emissions. The model has difficulty accurately capturing the fluctuations and short-term variability in the Helikite samples, but does quite well in representing the observed CO2ff in 15 min averaged surface flask samples and in ~ one week integrated CO2ff averages from grass samples. In this pilot study, we found that using grass samples, the modeled and observed CO2ff emissions averaged over one week agreed to within 30%. The results imply that greater verification accuracy may be achieved by including more detailed meteorological observations and refining 14C sampling strategies.

  5. The effect of packaging materials on the stability of sunscreen emulsions.

    PubMed

    Santoro, Maria Inês R M; Da Costa E Oliveira, Daniella Almança Gonçalves; Kedor-Hackmann, Erika R M; Singh, Anil K

    2005-06-13

    The purpose of this research was to study the stability of a emulsion containing UVA, UVB and infrared sunscreens after storage in different types of packaging materials (glass and plastic flasks; plastic and metallic tubes). The samples, emulsions containing benzophenone-3 (B-3), octyl methoxycinnamate (OM) and Phycocorail, were stored at 10, 25, 35 and 45 degrees C and representative samples were analyzed after 2, 7, 30, 60 and 90 days period. The stability studies were conducted by analyzing samples at pre-determined intervals by high performance liquid chromatography (HPLC) along with periodic rheological measurements.

  6. Long-term measurements of tropospheric carbon dioxide and its isotopes in coastal East Asia

    NASA Astrophysics Data System (ADS)

    Ou-Yang, C. F.; Lin, N. H.; Wang, J. L.; Schnell, R. C.

    2016-12-01

    Many studies have reported that Asian continental outflow has significantly impacted on global atmospheric chemistry, affecting air quality over the western Pacific, even as far as North America. Taiwan is situated at an ideal location in the western North Pacific for monitoring biomass burning and Asian dust coincided with polluted air masses originating from Southeast Asia and Asian continent. A high-elevation baseline station, Lulin Atmospheric Background Station (LABS; 23.47°N, 120.87°E; 2,862 m a.s.l.), was thus established in April 2006 to investigate the characteristics of trace gases and atmospheric transport patterns in the lower free troposphere. In March 2010, as part of GMD's Cooperative Air Sampling Network, flask air sampling at Dongsha Island (DSI; 20.70°N, 116.73°E; 3 m a.s.l.) was launched to measure surface greenhouse gases (GHGs) in the South China Sea. As reported by IPCC in 2013, CO2 is the largest contributor of the atmospheric well-mixed GHGs, accounting for 64.3% of the total global radiative forcing from 1750 to 2011. The annual mean CO2 mixing ratio reached the milestone of 400 ppm at LABS (402.6±3.1 ppm) in 2015 and at DSI (401.7±4.7 ppm) in 2014. Vegetation growth in spring drew down CO2 mixing ratios and elevated its stable isotope ratio (δ13C of CO2) at LABS and DSI in summer. By the continuous measurement of CO2 using a cavity ring-down spectroscopy, a daily minimum with a lager standard deviation was observed at LABS during daytime when photosynthesis was active. The CO2 increased at an average rate of +2.69±2.30 ppm at LABS and +2.10±1.32 ppm at DSI during the measurement period, whereas the δ13C isotope ratio of CO2 decreased at an average rate of -0.060±0.099 ‰ at LABS and -0.021±0.053 ‰ at DSI. Increasing trends for the δ18O isotope ratio of CO2 were found at both LABS and DSI in recent years.

  7. A mini-scale mass production and separation system for secretory heterologous proteins by perfusion culture of recombinant Pichia pastoris using a shaken ceramic membrane flask.

    PubMed

    Ohashi, R; Mochizuki, E; Suzuki, T

    1999-01-01

    The perfusion culture technique using a shaken ceramic membrane flask (SCM flask) was applied to the production of a secretory heterologous protein. A recombinant methylotrophic yeast strain, Pichia pastoris, was cultured aerobically on a reciprocal shaker using an SCM flask. High-level production of human serum albumin (HSA) was attempted by increasing both the cell concentration and the expression level of the recombinant gene. In the two-stage culture method, the cell concentration was first raised to 17 g/l by feeding glycerol, after which the expression of HSA was induced by feeding methanol. However, the concentration of HSA in the effluent filtrate was as low as 0.15 g/l, while the cell concentration continued to increase. In contrast, HSA was effectively produced by feeding methanol from an early stage of the culture. In this case, the HSA concentration reached 0.24 and 0.46 g/l, respectively, using the growth-associated production method without and with aeration into the head space of the SCM flask. The results showed that supplying sufficient oxygen together with the growth-associated induction method are effective for obtaining high-level expression of the methanol-inducible recombinant gene of P. pastoris. An HSA concentration in the filtrate of 1.5 g/l was finally achieved when the cell concentration was increased to 53 g/l by supplying oxygen-enriched gas to the SCM flask. The yield and productivity of HSA reached 2.6-fold and 10-fold those obtained in an ordinary fed-batch culture using a shake flask, and these levels were readily achieved by continuous replenishment of the culture supernatant. The achievements made in this study should contribute to the development of a handy bioreactor system for mini-scale mass production of target proteins with separation at high purity.

  8. Development of a novel method for amniotic fluid stem cell storage.

    PubMed

    Zavatti, Manuela; Beretti, Francesca; Casciaro, Francesca; Comitini, Giuseppina; Franchi, Fabrizia; Barbieri, Veronica; Bertoni, Laura; De Pol, Anto; La Sala, Giovanni B; Maraldi, Tullia

    2017-08-01

    Current procedures for collection of human amniotic fluid stem cells (hAFSCs) indicate that cells cultured in a flask for 2 weeks can then be used for research. However, hAFSCs can be retrieved directly from a small amount of amniotic fluid that can be obtained at the time of diagnostic amniocentesis. The aim of this study was to determine whether direct freezing of amniotic fluid cells is able to maintain or improve the potential of a sub-population of stem cells. We compared the potential of the hAFSCs regarding timing of freezing, cells obtained directly from amniotic fluid aspiration (D samples) and cells cultured in a flask before freezing (C samples). Colony-forming-unit ability, proliferation, morphology, stemness-related marker expression, senescence, apoptosis and differentiation potential of C and D samples were compared. hAFSCs isolated from D samples expressed mesenchymal stem cells markers until later passages, had a good proliferation rate and exhibited differentiation capacity similar to hAFSCs of C samples. Interestingly, direct freezing induced a higher concentration of cells positive for pluripotency stem cell markers, without teratoma formation in vivo. This study suggests that minimal processing may be adequate for the banking of amniotic fluid cells, avoiding in vitro passages before the storage and exposure to high oxygen concentration, which affect stem cell properties. This technique might be a cost-effective and reasonable approach to the process of Good Manufacturing Process accreditation for stem-cell banks. Copyright © 2017 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  9. Evaluation of steam penetration and sterilization of natural latex wraps.

    PubMed

    Rossanese, Matteo; Gasson, James; Barker, Colin; Bowlt, Kelly

    2014-11-01

    To evaluate the efficacy of steam and ethylene oxide (EtO) sterilization of Vetrap™ bandages. Prospective experimental study. Vetrap™ bandages (n = 70; 35 as supplied by the manufacturer, 35 unwound and tightly rewound). Vetrap™ bandage rolls (n = 60) marked with a 1 cm square were inoculated with 0.1 mL Geobacillus stearothermophilus spores, packaged in a pouch together with independent sterilization indicators and assigned into 3 sub-groups for sterilizer type: dynamic air removal, gravity displacement, and bench-top pre-vacuum and further sub-divided into 2 sterilization temperatures. Vetrap™ bandages rolls (n = 10) were inoculated with 0.1 mL Bacillus atrophaeus spores in the same manner and underwent EtO sterilization. After sterilization, the 1 cm marked square was aseptically resected to the level of the cardboard tube and enriched in a flask containing 10 mL tryptic soy broth for 24 hours at 60°C for G. stearothermophilus and 37°C for B. atrophaeus. Aliquots were subsequently plated on a Petri dish of tryptic soy agar and incubated at 60°C for G. stearothermophilus and 37°C for B. atrophaeus for 24 hours. Samples were scored positive if colonies of indicator organism were present on the nutrient agar after 24 hours. Three Vetrap™ bandages yielded post-sterilization growth of G. stearothermophilus: 2 from the dynamic air removal sterilizer at 134°C for 3.5 minutes, and 1 from the bench-top pre-vacuum sterilizer at 121°C for 15 minutes. After EtO sterilization, no positive samples were detected. Steam sterilization may be incomplete for Vetrap™ bandages whereas EtO showed complete destruction of resistant bacterial spores. © Copyright 2014 by The American College of Veterinary Surgeons.

  10. 9 CFR 147.15 - Laboratory procedure recommended for the bacteriological examination of mycoplasma reactors. 12

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10523. (5) Use sterile deionized distilled water to reconstitute penicillin. (6) Sterile serum should be... samples (ml)—5.0 (1:2000) Mycoplasma Broth Base (g)—22.5 Aqueous penicillin (units)—500,000 Sterile serum... Aqueous penicillin (units)—400,000 NAD (ml)—12.5 Cysteine hydrochloride (ml)—12.5 (1) Rotate flask gently...

  11. 9 CFR 147.15 - Laboratory procedure recommended for the bacteriological examination of mycoplasma reactors. 12

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10523. (5) Use sterile deionized distilled water to reconstitute penicillin. (6) Sterile serum should be... samples (ml)—5.0 (1:2000) Mycoplasma Broth Base (g)—22.5 Aqueous penicillin (units)—500,000 Sterile serum... Aqueous penicillin (units)—400,000 NAD (ml)—12.5 Cysteine hydrochloride (ml)—12.5 (1) Rotate flask gently...

  12. 9 CFR 147.15 - Laboratory procedure recommended for the bacteriological examination of mycoplasma reactors. 12

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10523. (5) Use sterile deionized distilled water to reconstitute penicillin. (6) Sterile serum should be... samples (ml)—5.0 (1:2000) Mycoplasma Broth Base (g)—22.5 Aqueous penicillin (units)—500,000 Sterile serum... Aqueous penicillin (units)—400,000 NAD (ml)—12.5 Cysteine hydrochloride (ml)—12.5 (1) Rotate flask gently...

  13. Growth of plant root cultures in liquid- and gas-dispersed reactor environments.

    PubMed

    McKelvey, S A; Gehrig, J A; Hollar, K A; Curtis, W R

    1993-01-01

    The growth of Agrobacterium transformed "hairy root" cultures of Hyoscyamus muticus was examined in various liquid- and gas-dispersed bioreactor configurations. Reactor runs were replicated to provide statistical comparisons of nutrient availability on culture performance. Accumulated tissue mass in submerged air-sparged reactors was 31% of gyratory shake-flask controls. Experiments demonstrate that poor performance of sparged reactors is not due to bubble shear damage, carbon dioxide stripping, settling, or flotation of roots. Impaired oxygen transfer due to channeling and stagnation of the liquid phase are the apparent causes of poor growth. Roots grown on a medium-perfused inclined plane grew at 48% of gyratory controls. This demonstrates the ability of cultures to partially compensate for poor liquid distribution through vascular transport of nutrients. A reactor configuration in which the medium is sprayed over the roots and permitted to drain down through the root tissue was able to provide growth rates which are statistically indistinguishable (95% T-test) from gyratory shake-flask controls. In this type of spray/trickle-bed configuration, it is shown that distribution of the roots becomes a key factor in controlling the rate of growth. Implications of these results regarding design and scale-up of bioreactors to produce fine chemicals from root cultures are discussed.

  14. Liquid films on shake flask walls explain increasing maximum oxygen transfer capacities with elevating viscosity.

    PubMed

    Giese, Heiner; Azizan, Amizon; Kümmel, Anne; Liao, Anping; Peter, Cyril P; Fonseca, João A; Hermann, Robert; Duarte, Tiago M; Büchs, Jochen

    2014-02-01

    In biotechnological screening and production, oxygen supply is a crucial parameter. Even though oxygen transfer is well documented for viscous cultivations in stirred tanks, little is known about the gas/liquid oxygen transfer in shake flask cultures that become increasingly viscous during cultivation. Especially the oxygen transfer into the liquid film, adhering on the shake flask wall, has not yet been described for such cultivations. In this study, the oxygen transfer of chemical and microbial model experiments was measured and the suitability of the widely applied film theory of Higbie was studied. With numerical simulations of Fick's law of diffusion, it was demonstrated that Higbie's film theory does not apply for cultivations which occur at viscosities up to 10 mPa s. For the first time, it was experimentally shown that the maximum oxygen transfer capacity OTRmax increases in shake flasks when viscosity is increased from 1 to 10 mPa s, leading to an improved oxygen supply for microorganisms. Additionally, the OTRmax does not significantly undermatch the OTRmax at waterlike viscosities, even at elevated viscosities of up to 80 mPa s. In this range, a shake flask is a somehow self-regulating system with respect to oxygen supply. This is in contrary to stirred tanks, where the oxygen supply is steadily reduced to only 5% at 80 mPa s. Since, the liquid film formation at shake flask walls inherently promotes the oxygen supply at moderate and at elevated viscosities, these results have significant implications for scale-up. © 2013 Wiley Periodicals, Inc.

  15. Summer 2015 Internship Abstract

    NASA Technical Reports Server (NTRS)

    Smith, Courtney

    2015-01-01

    Green fluorescent protein (GFP) visually shows the expression of proteins by fluorescing when exposed to certain wavelengths of light. The GFP in this experiment was used to identify cells actively releasing viruses. The experiment focused on the effect of microgravity on the GFP expression of Akata B-cells infected with Epstein Barr Virus (EBV). Two flasks were prepared with 30 million cells each and two bioreactors were prepared with 50 million cells each. All four cultures were incubated for 16 days and fed every four days. Cellometer readings were taken on the feeding days to find cell size, viability, and GFP expression. In addition, the cells were treated with Propodium monoazide (PMA) and run through real time PCR to determine viral load on the feeding days. On the International Space Station air samples are taken to analyze the bacterial and fungal organisms in the air. The Sartorius Portable Airport is being investigated for potential use on the ISS to analyze for viral content in the air. Multiple samples were taken around Johnson Space Center building 37 and in Clear Lake Pediatric Clinic. The filter used was the gelatin membrane filter and the DNA was extracted directly from the filter. The DNA was then run through real time PCR for Varicella Zoster Virus (VZV) and EBV as well as GAPDH to test for the presence of DNA. The results so far have shown low DNA yield and no positive results for VZV or EBV. Further inquiry involves accurately replicating an atmosphere with high viral load from saliva as would be found on the ISS to run the air sampler in. Another line of research is stress hormones that may be correlated to the reactivation of latent viruses. The stress hormones from saliva samples are analyzed rather than blood samples. The quantity found in saliva shows the quantity of the hormones actually attached to cells and causing a reaction, whereas in the blood the quantity of hormones is the total amount released to cause a reaction. The particular hormones tested for were cortisol, alpha-amylase, and DHEA. The DHEA was very high in the two control samples tested. Regularly, samples came into the lab from local clinics to be tested for various viruses. Saliva, blood, body scrapes, and tears were received from the clinics and then run for VZV, EBV, and Human Simplex Virus 1 (HSV-1) with the results then reported back to the clinician. Blood, saliva, and urine from astronauts were also tested for viruses and logged. In addition, several cell cultures were brought up and grown, including adherent Human Lung Fibroblast (HFL) cells infected with VZV, and Akata B-cells infected with EBV.

  16. Expansion of Human Mesenchymal Stem Cells in a Microcarrier Bioreactor.

    PubMed

    Tsai, Ang-Chen; Ma, Teng

    2016-01-01

    Human mesenchymal stem cells (hMSCs) are considered as a primary candidate in cell therapy owing to their self-renewability, high differentiation capabilities, and secretions of trophic factors. In clinical application, a large quantity of therapeutically competent hMSCs is required that cannot be produced in conventional petri dish culture. Bioreactors are scalable and have the capacity to meet the production demand. Microcarrier suspension culture in stirred-tank bioreactors is the most widely used method to expand anchorage dependent cells in a large scale. Stirred-tank bioreactors have the potential to scale up and microcarriers provide the high surface-volume ratio. As a result, a spinner flask bioreactor with microcarriers has been commonly used in large scale expansion of adherent cells. This chapter describes a detailed culture protocol for hMSC expansion in a 125 mL spinner flask using microcarriers, Cytodex I, and a procedure for cell seeding, expansion, metabolic sampling, and quantification and visualization using microculture tetrazolium (MTT) reagent.

  17. Does bottle type and acid-washing influence trace element analyses by ICP-MS on water samples? A test covering 62 elements and four bottle types: high density polyethene (HDPE), polypropene (PP), fluorinated ethene propene copolymer (FEP) and perfluoroalkoxy polymer (PFA).

    PubMed

    Reimann, C; Siewers, U; Skarphagen, H; Banks, D

    1999-10-01

    Groundwater samples from 15 boreholes in crystalline bedrock aquifers in South Norway (Oslo area) have been collected in parallel in five different clear plastic bottle types (high density polyethene [HDPE], polypropene [PP, two manufacturers], fluorinated ethene propene copolymer [FEP] and perfluoroalkoxy polymer [PFA]. In the cases of polyethene and polypropene, parallel samples have been collected in factory-new (unwashed) bottles and acid-washed factory-new bottles. Samples have been analysed by ICP-MS techniques for a wide range of inorganic elements down to the ppt (ng/l) range. It was found that acid-washing of factory-new flasks had no clear systematic beneficial effect on analytical result. On the contrary, for the PP-bottles concentrations of Pb and Sn were clearly elevated in the acid-washed bottles. Likewise, for the vast majority of elements, bottle type was of no importance for analytical result. For six elements (Al, Cr, Hf, Hg, Pb and Sn) some systematic differences for one or more bottle types could be tentatively discerned, but in no case was the discrepancy of major cause for concern. The most pronounced effect was for Cr, with clearly elevated concentrations returned from the samples collected in HDPE bottles, regardless of acid-washing or not. For the above six elements, FEP or PFA bottles seemed to be marginally preferable to PP and HDPE. In general, cheap HDPE, factory new, unwashed flasks are suitable for sampling waters for ICP-MS ultra-trace analysis of the elements tested.

  18. Enhancement in lipid content of Chlorella sp. MJ 11/11 from the spent medium of thermophilic biohydrogen production process.

    PubMed

    Ghosh, Supratim; Roy, Shantonu; Das, Debabrata

    2017-01-01

    The present study investigates the effect of spent media of acetogenic dark fermentation for mixotrophic algal cultivation for biodiesel production. Mixotrophic growth conditions were optimized in culture flask (250mL) using Chlorella sp. MJ 11/11. Maximum lipid accumulation (58% w/w) was observed under light intensity, pH, nitrate and phosphate concentration of 100μmolm -2 s -1 , 7, 2.7mM and 1.8mM, respectively. Air lift (1.4L) and flat panel (1.4L) reactors were considered for algal cultivation. Air lift showed significant improvement in biomass and lipid production as compared to flat panel reactor. The results could help in development of sustainable technology involving acetogenic hydrogen production integrated with sequential mitigation of spent media by algal cultivation for improved energy recovery. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. THE FEDERAL INTEGRATED BIOTREATMENT RESEARCH CONSORTIUM (FLASK TO FIELD)

    EPA Science Inventory

    The Federal Integrated Biotreatment Research Consortium (Flask to Field) represented a 7-year concerted effort by several research laboratories to develop bioremediation technologies for contaminated DoD sites. The consortium structure consisted of a director and four thrust are...

  20. The Oxygen Flask Method

    ERIC Educational Resources Information Center

    Boulton, L. H.

    1973-01-01

    Discusses application of Schoniger's method of quantitative organic elemental analysis in teaching of qualitative analysis of the halogens, nitrogen, sulphur, and phosphorus. Indicates that the oxygen flask method is safe and suitable for both high school and college courses because of simple apparatus requirements. (CC)

  1. Historical overview of the Biosphere 2 project

    NASA Technical Reports Server (NTRS)

    Allen, John P.

    1990-01-01

    An extensive historical overview is given of the Biosphere 2 project. The overview begins in late 1969, as the moon landings commenced, when work began on ecological projects which laid the conceptual foundation for the current Biosphere 2 project. Continuing through to taking a complete functional suite of microbes together with their associated aquatic elements and an air volume and putting them inside a closed lab flask in which to measure the oxygen and CO2 levels, study energy flows and visually observe the changes therein. The laws of biospherics formulated by the author which can be tested in the Biosphere 2 project are listed.

  2. Extraction of CO2 from air samples for isotopic analysis and limits to ultra high precision delta18O determination in CO2 gas.

    PubMed

    Werner, R A; Rothe, M; Brand, W A

    2001-01-01

    The determination of delta18O values in CO2 at a precision level of +/-0.02 per thousand (delta-notation) has always been a challenging, if not impossible, analytical task. Here, we demonstrate that beyond the usually assumed major cause of uncertainty - water contamination - there are other, hitherto underestimated sources of contamination and processes which can alter the oxygen isotope composition of CO2. Active surfaces in the preparation line with which CO2 comes into contact, as well as traces of air in the sample, can alter the apparent delta18O value both temporarily and permanently. We investigated the effects of different surface materials including electropolished stainless steel, Duran glass, gold and quartz, the latter both untreated and silanized. CO2 frozen with liquid nitrogen showed a transient alteration of the 18O/16O ratio on all surfaces tested. The time to recover from the alteration as well as the size of the alteration varied with surface type. Quartz that had been ultrasonically cleaned for several hours with high purity water (0.05 microS) exhibited the smallest effect on the measured oxygen isotopic composition of CO2 before and after freezing. However, quartz proved to be mechanically unstable with time when subjected to repeated large temperature changes during operation. After several days of operation the gas released from the freezing step contained progressively increasing trace amounts of O2 probably originating from inclusions within the quartz, which precludes the use of quartz for cryogenically trapping CO2. Stainless steel or gold proved to be suitable materials after proper pre-treatment. To ensure a high trapping efficiency of CO2 from a flow of gas, a cold trap design was chosen comprising a thin wall 1/4" outer tube and a 1/8" inner tube, made respectively from electropolished stainless steel and gold. Due to a considerable 18O specific isotope effect during the release of CO2 from the cold surface, the thawing time had to be as long as 20 min for high precision delta18O measurements. The presence of traces of air in almost all CO2 gases that we analyzed was another major source of error. Nitrogen and oxygen in the ion source of our mass spectrometer (MAT 252, Finnigan MAT, Bremen, Germany) give rise to the production of NO2 at the hot tungsten filament. NO2+ is isobaric with C16O18O+ (m/z 46) and interferes with the delta18O measurement. Trace amounts of air are present in CO2 extracted cryogenically from air at -196 degrees C. This air, trapped at the cold surface, cannot be pumped away quantitatively. The amount of air present depends on the surface structure and, hence, the alteration of the measured delta18O value varies with the surface conditions. For automated high precision measurement of the isotopic composition of CO2 of air samples stored in glass flasks an extraction interface ('BGC-AirTrap') was developed which allows 18 analyses (including standards) per day to be made. For our reference CO2-in-air, stored in high pressure cylinders, the long term (>9 months) single sample precision was 0.012 per thousand for delta13C and 0.019 per thousand for delta18O. Copyright 2001 John Wiley & Sons, Ltd.

  3. In vitro penetration of swine oocytes by homologous spermatozoa: Distinct systems for gamete's co-incubation and oocyte's cryopreservation.

    PubMed

    Macedo, M C; Lucia, T; Rambo, G; Ferreira Filho, E B; Rosa, A P; Fabiane, C; Cabral, M; Deschamps, J C

    2010-02-01

    In vitro penetration (IVP) of swine oocytes by homologous spermatozoa was evaluated in two experiments using four boars as semen donors. In experiment 1, the IVP rate and the number of penetrating spermatozoa (PSP) were compared using three co-incubation systems for vitrified oocytes and fresh sperm: (1) 35mL petri dishes in a CO(2) incubator, (2) 35mL petri dishes in bags (submarine system) and (3) glass flasks partially submerged in water bath with the same gas mixture used for the bag system. Mean PSP was 8.2+/-10.1 and the IVP rate was 90.5%. The PSP differed across all systems (P=0.0006): 15.5+/-0.5 for flasks, 6.3+/-0.4 for CO(2), and 3.9+/-0.4 for bags. The IVP rate for flasks (95.0%) was greater (P=0.01) than for CO(2) and bags (90.8% and 85.0%, respectively), but it did not differ between flasks and CO(2) for three boars (P>0.05). In experiment 2, co-incubation was done as described for glass flasks in experiment 1. The IVP rate and PSP were compared for cryopreserved oocytes: either vitrified in open pulled straws (OPS), or frozen in cryotubes. Mean PSP was 5.4+/-6.5 and IVP rate was 89.6%. Both PSP and IVP rate were greater (P<0.0001) for oocytes frozen in cryotubes (7.0+/-0.3% and 95.8%, respectively) than those frozen in OPS (3.7+/-0.3% and 83.4%, respectively), with no differences found for three boars (P>0.05). In summary, successful IVP of swine oocytes by homologous spermatozoa can be achieved using gametes incubated in glass flasks and oocytes frozen in cryotubes.

  4. Atmospheric H2O2 measurement: comparison of cold trap method with impinger bubbling method

    NASA Technical Reports Server (NTRS)

    Sakugawa, H.; Kaplan, I. R.

    1987-01-01

    Collection of atmospheric H2O2 was performed by a cold trap method using dry ice-acetone as the refrigerant. The air was drawn by a pump into a glass gas trap immersed in the dry ice-acetone slush in a dewar flask at a flow rate of 2.5 l min-1 for approximately 2 h. Collection efficiency was > 99% and negligible interferences by O3, SO2 or organic matter with the collected H2O2 in the trap were observed. This method was compared with the air impinger bubbling method which has been previously described (Kok et al., 1978a, b, Envir. Sci. Technol. 12, 1072-1080). The measured total peroxide (H2O2 + organic peroxide) values in a series of aim samples collected by the impinger bubbling method (0.06-3.7 ppb) were always higher than those obtained by the cold trap method (0.02-1.2 ppb). Laboratory experiments suggest that the difference in values between the two methods probably results from the aqueous phase generation of H2O2 and organic peroxide in the impinger solution by a reaction of atmospheric O3 with olefinic and aromatic compounds. If these O3-organic compound reactions which occur in the impinger also occur in aqueous droplets in the atmosphere, the process could be very important for aqueous phase generation of H2O2 in clouds and rainwater.

  5. Dispersant Effectiveness Of Heavy Fuel Oils Using The Baffled Flask Test

    EPA Science Inventory

    Dispersants have been widely used as a primary response measure for marine oil spills around the world. Recently, the U.S. Environmental Protection Agency (EPA) developed an improved laboratory dispersant testing protocol, called the Baffled Flask Test (BFT). The BFT protocol w...

  6. Renewable Molecular Flasks with NADH Models: Combination of Light-Driven Proton Reduction and Biomimetic Hydrogenation of Benzoxazinones.

    PubMed

    Zhao, Liang; Wei, Jianwei; Lu, Junhua; He, Cheng; Duan, Chunying

    2017-07-17

    Using small molecules with defined pockets to catalyze chemical transformations resulted in attractive catalytic syntheses that echo the remarkable properties of enzymes. By modulating the active site of a nicotinamide adenine dinucleotide (NADH) model in a redox-active molecular flask, we combined biomimetic hydrogenation with in situ regeneration of the active site in a one-pot transformation using light as a clean energy source. This molecular flask facilitates the encapsulation of benzoxazinones for biomimetic hydrogenation of the substrates within the inner space of the flask using the active sites of the NADH models. The redox-active metal centers provide an active hydrogen source by light-driven proton reduction outside the pocket, allowing the in situ regeneration of the NADH models under irradiation. This new synthetic platform, which offers control over the location of the redox events, provides a regenerating system that exhibits high selectivity and efficiency and is extendable to benzoxazinone and quinoxalinone systems. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Corning HYPERFlask® for viral amplification and production of diagnostic reagents.

    PubMed

    Kearney, Brian J; Voorhees, Matthew A; Williams, Priscilla L; Olschner, Scott P; Rossi, Cynthia A; Schoepp, Randal J

    2017-04-01

    Viral preparations are essential components in diagnostic research and development. The production of large quantities of virus traditionally is done by infecting numerous tissue culture flasks or roller bottles, which require large incubators and/or roller bottle racks. The Corning HYPERFlask ® is a multilayer flask that uses a gas permeable film to provide gas exchange between the cells and culture medium and the atmospheric environment. This study evaluated the suitability of the HYPERFlask for production of Lassa, Ebola, Bundibugyo, Reston, and Marburg viruses and compared it to more traditional methods using tissue culture flasks and roller bottles. The HYPERFlask produced cultures were equivalent in virus titer and indistinguishable in immunodiagnostic assays. The use of the Corning HYPERFlask for viral production is a viable alternative to traditional tissue culture flasks and roller bottles. HYPERFlasks allow for large volumes of virus to be produced in a small space without specialized equipment. Copyright © 2016. Published by Elsevier B.V.

  8. Seasonal climatology of CO2 across North America from aircraft measurements in the NOAA/ESRL Global Greenhouse Gas Reference Network

    NASA Astrophysics Data System (ADS)

    Sweeney, Colm; Karion, Anna; Wolter, Sonja; Newberger, Timothy; Guenther, Doug; Higgs, Jack A.; Andrews, Arlyn Elyzabeth; Lang, Patricia M.; Neff, Don; Dlugokencky, Edward; Miller, John B.; Montzka, Stephen A.; Miller, Ben R.; Masarie, Ken Alan; Biraud, Sebastien Christophe; Novelli, Paul C.; Crotwell, Molly; Crotwell, Andrew M.; Thoning, Kirk; Tans, Pieter P.

    2015-05-01

    Seasonal spatial and temporal gradients for the CO2 mole fraction over North America are examined by creating a climatology from data collected 2004-2013 by the NOAA/ESRL Global Greenhouse Gas Reference Network Aircraft Program relative to trends observed for CO2 at the Mauna Loa Observatory. The data analyzed are from measurements of air samples collected in specially fabricated flask packages at frequencies of days to months at 22 sites over continental North America and shipped back to Boulder, Colorado, for analysis. These measurements are calibrated relative to the CO2 World Meteorological Organization mole fraction scale. The climatologies of CO2 are compared to climatologies of CO, CH4, SF6, N2O (which are also measured from this sampling program), and winds to understand the dominant transport and chemical and biological processes driving changes in the spatial and temporal mole fractions of CO2 as air passes over continental North America. The measurements show that air masses coming off the Pacific on the west coast of North America are relatively homogeneous with altitude. As air masses flow eastward, the lower section from the surface to 4000 m above sea level (masl) becomes distinctly different from the 4000-8000 masl section of the column. This is due in part to the extent of the planetary boundary layer, which is directly impacted by continental sources and sinks, and to the vertical gradient in west-to-east wind speeds. The slowdown and southerly shift in winds at most sites during summer months amplify the summertime drawdown relative to what might be expected from local fluxes. This influence counteracts the dilution of summer time CO2 drawdown (known as the "rectifier effect") as well as changes the surface influence "footprint" for each site. An early start to the summertime drawdown, a pronounced seasonal cycle in the column mean (500 to 8000 masl), and small vertical gradients in CO2, CO, CH4, SF6, and N2O at high-latitude western sites such as Poker Flat, Alaska, suggest recent influence of transport from southern latitudes and not local processes. This transport pathway provides a significant contribution to the large seasonal cycle observed in the high latitudes at all altitudes sampled. A sampling analysis of the NOAA/ESRL CarbonTracker model suggests that the average sampling resolution of 22 days is sufficient to get a robust estimate of mean seasonal cycle of CO2 during this 10 year period but insufficient to detect interannual variability in emissions over North America.

  9. Geochemistry of selected mercury mine-tailings in the Parkfield Mercury District, California

    USGS Publications Warehouse

    Rytuba, James J.; Kotlyar, Boris B.; Wilkerson, Gregg; Olson, Jerry

    2001-01-01

    The Parkfield mercury district is located in the southern part of the California Coast Range mercury mineral belt and contains three silica-carbonate-type mercury deposits that have had significant mercury production. Mercury was first produced in the district in 1873, but the main period of production occurred from 1915-1922. Total production from the district is about 5,000 flasks of mercury (a flask equals 76 pounds of mercury) with most production coming from the Patriquin mine (1,875 flasks), and somewhat less from the King (1,600 flasks) and Dawson (1,470 flasks) mines. Several other small prospects and mines occur in the district but only minor production has come from them. In 1969, Phelan Sulphur Company carried out mineral exploration at the King mine and announced the discovery of 55,000 tons of mercury ore with an average grade of 5.2 pounds per ton. The King mine is located on federal land administered by the U.S. Bureau of Land Management. Several other parcels of federal land are present adjacent to other mines and prospects in the Parkfield district. An environmental assessment of mine sites on and adjacent to federal land was carried out to determine the amount of mercury and other trace metals present in mine wastes and in sediments from streams impacted by past mining.

  10. On-line prediction of the glucose concentration of CHO cell cultivations by NIR and Raman spectroscopy: Comparative scalability test with a shake flask model system.

    PubMed

    Kozma, Bence; Hirsch, Edit; Gergely, Szilveszter; Párta, László; Pataki, Hajnalka; Salgó, András

    2017-10-25

    In this study, near-infrared (NIR) and Raman spectroscopy were compared in parallel to predict the glucose concentration of Chinese hamster ovary cell cultivations. A shake flask model system was used to quickly generate spectra similar to bioreactor cultivations therefore accelerating the development of a working model prior to actual cultivations. Automated variable selection and several pre-processing methods were tested iteratively during model development using spectra from six shake flask cultivations. The target was to achieve the lowest error of prediction for the glucose concentration in two independent shake flasks. The best model was then used to test the scalability of the two techniques by predicting spectra of a 10l and a 100l scale bioreactor cultivation. The NIR spectroscopy based model could follow the trend of the glucose concentration but it was not sufficiently accurate for bioreactor monitoring. On the other hand, the Raman spectroscopy based model predicted the concentration of glucose in both cultivation scales sufficiently accurately with an error around 4mM (0.72g/l), that is satisfactory for the on-line bioreactor monitoring purposes of the biopharma industry. Therefore, the shake flask model system was proven to be suitable for scalable spectroscopic model development. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Resource estimation from historical data: Mercury, a test case

    USGS Publications Warehouse

    Cargill, S.M.; Root, D.H.; Bailey, E.H.

    1980-01-01

    A simple technique based on historical records of tonnage and grade of ore produced provides a means for calculating how much of a mineral product will be available in the future at various average grades. Estimates made on this basis are independent of geologic considerations or changing economic and political factors, although they are based on mining history, which was largely determined by these factors. The relatively minor element, mercury, was used for the test case reported here, but the method has been found applicable to forecasts of resources for other mineral products. Mercury resources available in ore in which the average grade is as low as 0.1% are estimated to be 53 ??106kg (1.5 ??106flasks) for the United States and 1551 ??106kg (45 ??106flasks) for the world; this amount is more than adequate to meet predicted demand to the year 2000. The expectable price of mercury in 1978 dollars at this 0.1% grade is projected to be $58.75 per kg ($2,025 per flask), but at a 10% annual inflation rate, it would be more than $12,000 per flask. To satisfy just the projected U.S. demand for mercury by 2000, the price is calculated to be $48.96 per kg ($1,688 per flask) in 1978 dollars at an average annual grade of 0.12%. ?? 1980 Plenum Publishing Corporation.

  12. THE BAFFLED FLASK TEST FOR DISPERSANT EFFECTIVENESS: A ROUND ROBIN EVALUATION OF REPRODUCIBILITY AND REPEATABILITY

    EPA Science Inventory

    After two previous investigations demonstrated that the Baffled Flask Test (BFT) was an effective and reproducible method for screening the effectiveness of dispersant products in the laboratory, the USEPA decided that before the new protocol cold be considered for replacement of...

  13. EVALUATION OF MIXING ENERGY IN LABORATORY FLASKS USED FOR DISPERSANT EFFECTIVENESS TESTING

    EPA Science Inventory

    The evaluation of dispersant effectiveness used for oil spills is commonly done using tests conducted in laboratory flasks. The success of a test relies on replication of the conditions at sea. We used a hot wire anemometer to characterize the turbulence characteristics in the s...

  14. Fluid Thinking.

    ERIC Educational Resources Information Center

    Clift, Philip A.

    1992-01-01

    Provides a student worksheet and set-up instructions for a science experiment to demonstrate the concept of density. Students are asked to explain the phenomenon in which a liquid of lower density placed in the bottom of two vertical flasks flows up to replace the liquid of higher density in the upper flask. (MDH)

  15. Combustion Product Evaluation of Various Charge Sizes and Propellant Formulations. Task 1 Report: Sampling and Analytical Procedures Proposed for Use in Gun Propellant Combustion Product Characterization

    DTIC Science & Technology

    1988-01-01

    ml, 0.01N, NaOH + 1 ml 30% H202 H2S 10 ml. 0.01M CdSO4 + STRactan 10 in H2 Aldehydes 10 ml of 3.1 WM/ml 2.4- dinitrophenylhydrazine (DNPH) soln. in...3 15 IITRI C06673-TR1 I,ý 3. 3.1.2.6 Aldehydes I After sampling, the 11 flasks will be injected with 10 mi of a 3.1 14/mX -2,4- dinitrophenylhydrazine

  16. Condensation of acetol and acetic acid vapor with sprayed liquid

    USDA-ARS?s Scientific Manuscript database

    A cellulose-derived fraction of biomass pyrolysis vapor was simulated by evaporating acetol and acetic acid (AA) from flasks on a hot plate. The liquid in the flasks was infused with heated nitrogen. The vapor/nitrogen stream was superheated in a tube oven and condensed by contact with a cloud of ...

  17. Dissolved oxygen levels affect dimorphic growth by the entomopathogenic fungus Isaria fumosorosea

    USDA-ARS?s Scientific Manuscript database

    The entomopathogenic fungus Isaria fumosorosea is capable of dimorphic growth (hyphal or yeast-like) in submerged culture. In shake flask studies, we evaluated the impact of aeration on the mode of growth of I. fumosorosea. Using 250 mL baffled Erlenmeyer flasks, culture volumes of 50, 100, 150, a...

  18. 27 CFR 21.94 - Acetaldol.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 5 ml of this solution to a 250 ml glass-stoppered flask containing 25 ml distilled water. Add 25 ml of a freshly prepared 1 percent sodium bisulfite solution. Prepare a blank omitting the acetaldol solution. Place the flasks in a dark place away from excessive heat or cold and allow to stand six hours...

  19. 27 CFR 21.94 - Acetaldol.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 5 ml of this solution to a 250 ml glass-stoppered flask containing 25 ml distilled water. Add 25 ml of a freshly prepared 1 percent sodium bisulfite solution. Prepare a blank omitting the acetaldol solution. Place the flasks in a dark place away from excessive heat or cold and allow to stand six hours...

  20. 27 CFR 21.94 - Acetaldol.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 5 ml of this solution to a 250 ml glass-stoppered flask containing 25 ml distilled water. Add 25 ml of a freshly prepared 1 percent sodium bisulfite solution. Prepare a blank omitting the acetaldol solution. Place the flasks in a dark place away from excessive heat or cold and allow to stand six hours...

  1. 27 CFR 21.94 - Acetaldol.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 5 ml of this solution to a 250 ml glass-stoppered flask containing 25 ml distilled water. Add 25 ml of a freshly prepared 1 percent sodium bisulfite solution. Prepare a blank omitting the acetaldol solution. Place the flasks in a dark place away from excessive heat or cold and allow to stand six hours...

  2. 27 CFR 21.94 - Acetaldol.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 5 ml of this solution to a 250 ml glass-stoppered flask containing 25 ml distilled water. Add 25 ml of a freshly prepared 1 percent sodium bisulfite solution. Prepare a blank omitting the acetaldol solution. Place the flasks in a dark place away from excessive heat or cold and allow to stand six hours...

  3. Process for casting hard-faced, lightweight camshafts and other cylindrical products

    DOEpatents

    Hansen, Jeffrey S.; Turner, Paul C.; Argetsinger, Edward R.; Wilson, Rick D.

    1996-01-01

    A process for casting a hard-faced cylindrical product such as an automobile camshaft includes the steps of: (a) preparing a composition formed from a molten base metal and an additive in particle form and having a hardness value greater than the hardness value of the base metal; (b) introducing the composition into a flask containing a meltable pattern of a cylindrical product such as an automobile camshaft to be manufactured and encased in sand to allow the composition to melt the pattern and assume the shape of the pattern within the sand; and (c) rotating the flask containing the pattern about the longitudinal axes of both the flask and the pattern as the molten base metal containing the additive in particle form is introduced into the flask to cause particles of the additive entrained in the molten base metal to migrate by centrifugal action to the radial extremities of the pattern and thereby provide a cylindrical product having a hardness value greater at it's radial extremities than at its center when the molten base metal solidifies.

  4. Gas chromatographic quantitation of underivatized amines in the determination of their octanol-0.1 M sodium hydroxide partition coefficients by the shake-flask method.

    PubMed

    Grunewald, G L; Pleiss, M A; Gatchell, C L; Pazhenchevsky, R; Rafferty, M F

    1984-06-01

    The use of gas chromatography (GC) for the determination of 0.1 M sodium hydroxide-octanol partition coefficients (log P) for a wide variety of ethylamines is demonstrated. The conventional shake-flask procedure (SFP) is utilized, with the addition of an internal reference, which is cleanly separated from the desired solute and solvents on a 10% Apiezon L, 2% potassium hydroxide on 80-100 mesh Chromosorb W AW column. The partitioned solute is extracted from the aqueous phase with chloroform and analyzed by GC. The method provides an accurate and highly reproducible means of determining log P values, as demonstrated by the low relative standard errors. The technique is both rapid and extremely versatile. The use of the internal standard method of analysis introduces consistency, since variables like the exact weight of solute are not necessary (unlike the traditional SFP) and the volume of sample injected is not critical. The technique is readily accessible to microgram quantities of solutes, making it ideal for a wide range of volatile, amine-bearing compounds.

  5. Sensory Flask Cells in Sponge Larvae Regulate Metamorphosis via Calcium Signaling.

    PubMed

    Nakanishi, Nagayasu; Stoupin, Daniel; Degnan, Sandie M; Degnan, Bernard M

    2015-12-01

    The Porifera (sponges) is one of the earliest phyletic lineages to branch off the metazoan tree. Although the body-plan of sponges is among the simplest in the animal kingdom and sponges lack nervous systems that communicate environmental signals to other cells, their larvae have sensory systems that generate coordinated responses to environmental cues. In eumetazoans (Cnidaria and Bilateria), the nervous systems of larvae often regulate metamorphosis through Ca(2+)-dependent signal transduction. In sponges, neither the identity of the receptor system that detects an inductive environmental cue (hereafter "metamorphic cues") nor the signaling system that mediates settlement and metamorphosis are known. Using a combination of behavioral assays and surgical manipulations, we show here that specialized epithelial cells-referred to as flask cells-enriched in the anterior third of the Amphimedon queenslandica larva are most likely to be the sensory cells that detect the metamorphic cues. Surgical removal of the region enriched in flask cells in a larva inhibits the initiation of metamorphosis. The flask cell has an apical sensory apparatus with a cilium surrounded by an apical F-actin-rich protrusion, and numerous vesicles, hallmarks of eumetazoan sensory-neurosecretory cells. We demonstrate that these flask cells respond to metamorphic cues by elevating intracellular Ca(2+) levels, and that this elevation is necessary for the initiation of metamorphosis. Taken together, these analyses suggest that sponge larvae have sensory-secretory epithelial cells capable of converting exogenous cues into internal signals via Ca(2+)-mediated signaling, which is necessary for the initiation of metamorphosis. Similarities in the morphology, physiology, and function of the sensory flask cells in sponge larvae with the sensory/neurosecretory cells in eumetazoan larvae suggest this sensory system predates the divergence of Porifera and Eumetazoa. © The Author 2015. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.

  6. The O-mannosylation and production of recombinant APA (45/47 KDa) protein from Mycobacterium tuberculosis in Streptomyces lividans is affected by culture conditions in shake flasks.

    PubMed

    Gamboa-Suasnavart, Ramsés A; Valdez-Cruz, Norma A; Cordova-Dávalos, Laura E; Martínez-Sotelo, José A; Servín-González, Luis; Espitia, Clara; Trujillo-Roldán, Mauricio A

    2011-12-20

    The Ala-Pro-rich O-glycoprotein known as the 45/47 kDa or APA antigen from Mycobacterium tuberculosis is an immunodominant adhesin restricted to mycobacterium genus and has been proposed as an alternative candidate to generate a new vaccine against tuberculosis or for diagnosis kits. In this work, the recombinant O-glycoprotein APA was produced by the non-pathogenic filamentous bacteria Streptomyces lividans, evaluating three different culture conditions. This strain is known for its ability to produce heterologous proteins in a shorter time compared to M. tuberculosis. Three different shake flask geometries were used to provide different shear and oxygenation conditions; and the impact of those conditions on the morphology of S. lividans and the production of rAPA was characterized and evaluated. Small unbranched free filaments and mycelial clumps were found in baffled and coiled shake flasks, but one order of magnitude larger pellets were found in conventional shake flasks. The production of rAPA is around 3 times higher in small mycelia than in larger pellets, most probably due to difficulties in mass transfer inside pellets. Moreover, there are four putative sites of O-mannosylation in native APA, one of which is located at the carboxy-terminal region. The carbohydrate composition of this site was determined for rAPA by mass spectrometry analysis, and was found to contain different glycoforms depending on culture conditions. Up to two mannoses residues were found in cultures carried out in conventional shake flasks, and up to five mannoses residues were determined in coiled and baffled shake flasks. The shear and/or oxygenation parameters determine the bacterial morphology, the productivity, and the O-mannosylation of rAPA in S. lividans. As demonstrated here, culture conditions have to be carefully controlled in order to obtain recombinant O-glycosylated proteins with similar "quality" in bacteria, particularly, if the protein activity depends on the glycosylation pattern. Furthermore, it will be an interesting exercise to determine the effect of shear and oxygen in shake flasks, to obtain evidences that may be useful in scaling-up these processes to bioreactors. Another approach will be using lab-scale bioreactors under well-controlled conditions, and study the impact of those on rAPA productivity and quality.

  7. Variations of atmospheric CH4, N2O and SF6 over Japan and the East China Sea

    NASA Astrophysics Data System (ADS)

    Ishijima, K.; Goto, D.; Ishidoya, S.; Yashiro, H.; Umezawa, T.; Sugawara, S.; Patra, P. K.; Muromachi, A.; Elkins, J. W.; Dutton, G. S.; Dlugokencky, E. J.; Morimoto, S.; Aoki, S.; Nakazawa, T.

    2013-12-01

    East Asia is one of the most important regions for anthropogenic sources of both short-lived air pollutants and long-lived greenhouse gases (GHGs). According to recent estimates from an emission database, China has become the largest emitter of long-lived GHGs. Since Japan and the East China Sea are located at the east end of Eurasia, atmospheric species emitted from the continent are transported over them throughout the year. Particularly in winter to spring, outflow of the emitted species is enhanced over the East China Sea due to the East Asian Monsoon. To monitor temporal and spatial variability of atmospheric GHGs in the East Asian region, we conducted systematic GHG observations during 2003-2012 from flask samples collected onboard four different commercial ferry boats, which connected between Wakkanai and Rishiri islands (WAK ; 45.4°N, 141.5°E), between Sakaiminato and Oki islands (OKI ; 35.8°N, 133.2°E), between Kagoshima and Okinawa islands (RYU ; 30.0°N, 130.0°E), and between Ishigaki and Hateruma islands (HTR ; 24.0°N, 124.0°E). Air samples were collected almost weekly, and they were sent to Tohoku University and analyzed for GHGs and related gases. In this study, we present analyses of observed CH4, N2O and SF6 concentrations in comparison with simulations by the Atmospheric general circulation model-based Chemistry Transport model (ACTM). The observed three species predictably show higher concentrations than those observed at Cape Kumukahi (KUM), which is a NOAA air sampling site located in the Central Pacific, reflecting strong outflow of the species from East Asia. Annual mean latitudinal gradients found from the four locations as well as decrease toward KUM are generally reproduced by the ACTM. This is mostly because of reasonable spatial distributions in GHG emissions given in the ACTM. The three species also show discernible seasonal cycles. ACTM simulates seasonal cycles of CH4 and SF6 relatively well, but not for N2O, suggesting deficiency of our present understanding of N2O sources in East Asia. Further details including tagged simulations for CH4 regional emission will be shown in our presentation.

  8. Real time, ambient air laser monitor for rare CO2 isotopic tracers: Δ13 C18 O16 O and Δ17 O

    NASA Astrophysics Data System (ADS)

    Nelson, David; Shorter, Joanne; McManus, Barry; Jervis, Dylan; Zahniser, Mark; Ono, Shuhei

    2017-04-01

    Greenhouse gas (GHG) emissions are the primary drivers of global climate change and hence there is a crucial need to quantify their sources and sinks. A powerful technique to help constrain source and sink strengths in GHG exchange processes is the analysis of the relative proportions of isotopic variants of GHGs. We present a new laser isotope monitor based on Tunable Infrared Laser Direct Absorption Spectroscopy (TILDAS) to measure the primary clumped isotopologue of CO2 (Δ13 C18 O16 O) and to simultaneously measure the mass independent 17 O-CO2 content (Δ17 O). The instrument directly measures dried atmospheric samples without cryogenic preconcentration of CO2 . The instrument has several novel features. The instrument's sensitivity is enhanced by employing a 400 meter optical absorption cell. Measurement drift is suppressed by using a rapid sample switching method with frequent comparison to a working reference. A new dual-pressure measurement scheme is demonstrated. This scheme solves the dynamic range challenge that arises in simultaneously measuring the main isotopologues of CO2 together with much less abundant clumped isotopologue species. Our initial results address measurement precision, measurement drift and calibration. We show the potential to reach 0.03 per mil repeatability with time resolution of 3 minutes and with minimal drift over an 18 hour measurement period. The instrument is sufficiently compact to be field deployed thus providing the possibility of continuous measurements of Δ13 C18 O16 O and Δ17 O rather than occasional flask samples.

  9. 21 CFR 177.1970 - Vinyl chloride-lauryl vinyl ether copolymers.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... of the flask at 150 °F for 2 hours using a hot plate while also maintaining gentle mechanical agitation. Filter the contents of the flask rapidly through No. 42 Whatman filter paper with the aid of suction. Transfer the filtrate to flat glass dishes that are warmed on a hot plate and evaporate the...

  10. Misconceptions in the Exploding Flask Demonstration Resolved through Students' Critical Thinking

    ERIC Educational Resources Information Center

    Spierenburg, Rick; Jacobse, Leon; de Bruin, Iris; van den Bos, Daan J.; Vis, Dominique M.; Juurlink, Ludo B. F.

    2017-01-01

    As it connects to a large set of important fundamental ideas in chemistry and analytical techniques discussed in high school chemistry curricula, we review the exploding flask demonstration. In this demonstration, methanol vapor is catalytically oxidized by a Pt wire catalyst in an open container. The exothermicity of reactions occurring at the…

  11. Using PETRIMES to estimate mercury deposits in California

    USGS Publications Warehouse

    Lee, P.J.; Singer, D.A.

    1994-01-01

    In this article, we examine the use of an unconventional procedure, PETRIMES, to estimate mineral resources of mercury deposits in California. The study, which is based on the nonparametric discovery process model and Q-Q plots, suggests that a lognormal distribution is appropriate for the mercury deposits in California. The results of the assessment are summarized as follows: (1) the total number of mercury deposits in the population is approximately 165; (2) the median value of the largest undiscovered deposit size is 487 flasks; (3) the mean of the remaining mercury potential is 2,500 flasks; and (4) the population resource ranges from 1,040,000 to 4,300,000 flasks (at a 0.9 probability level). ?? 1994 Oxford University Press.

  12. Improved Segmented-Flow Tracer-Monitored Titration for Automated Measurement of Total Alkalinity in Seawater

    NASA Astrophysics Data System (ADS)

    Spaulding, R. S.; Hales, B.; Beck, J. C.; Degrandpre, M. D.

    2008-12-01

    The four measurable inorganic carbon parameters commonly measured as part of oceanic carbon cycle studies are total dissolved inorganic carbon (DIC), total alkalinity (AT), hydrogen ion concentration (pH) and partial pressure of CO2 (pCO2). AT determination is critical for anthropogenic CO2 inventory calculations and for quantifying CaCO3 saturation. Additionally, measurement of AT in combination with one other carbonate parameter can be used to describe the inorganic carbon equilibria. Current methods for measuring AT require calibrated volumetric flasks and burettes, gravimetry, or precise flow measurements. These methods also require analysis times of ˜15 min and sample volumes of ˜200 mL, and sample introduction is not automated, resulting in labor-intensive measurements and low temporal resolution. The Tracer Monitored Titration (TMT) system was previously developed at the University of Montana for AT measurements. The TMT is not dependent on accurate gravimetric, volumetric or flow rate measurements because it relies on a pH-sensitive indicator (tracer) to track the amount of titrant added to the sample. Sample and a titrant-indicator mixture are mechanically stirred in an optical flow cell and pH is calculated using the indicator equilibrium constant and the spectrophotometrically determined concentrations of the acid and base forms of the indicator. AT is then determined using these data in a non-linear least squares regression of the AT mass and proton balances. The precision and accuracy of the TMT are 2 and 4 micromol per kg in 16 min using 110-mL of sample. The TMT is dependent on complete mixing of titrant with the sample and accurate absorbance measurements. We have developed the segmented-flow TMT (SF- TMT) to improve on these aspects and decrease sample analysis time. The TMT uses segmented flow instead of active mixing and a white LED instead of a tungsten-halogen light source. Air is added to the liquid flow stream, producing segments of liquid separated by air bubbles. Because liquid is not transferred between flow segments, there is rapid flushing which reduces sample volume to <10 mL. Additionally, the slower movement of liquid at the tube walls compared to that at the tube center creates circulation within each liquid segment, mixing the sample and eliminating the need for mechanical stirring. The white LED has higher output at the wavelengths of interest, thus improving the precision of absorbance measurements. These improvements result in a faster, simpler method for measuring AT.

  13. Cultivation characteristics and gene expression profiles of Aspergillus oryzae by membrane-surface liquid culture, shaking-flask culture, and agar-plate culture.

    PubMed

    Imanaka, Hiroyuki; Tanaka, Soukichi; Feng, Bin; Imamura, Koreyoshi; Nakanishi, Kazuhiro

    2010-03-01

    We cultivated a filamentous fungus, Aspergillus oryzae IAM 2706 by three different cultivation methods, i.e., shaking-flask culture (SFC), agar-plate culture (APC), and membrane-surface liquid culture (MSLC), to elucidate the differences of its behaviors by different cultivation methods under the same media, by measuring the growth, secretion of proteases and alpha-amylase, secreted protein level, and gene transcriptional profile by the DNA microarray analysis. The protease activities detected by MSLC and APC were much higher than that by SFC, using both modified Czapek-Dox (mCD) and dextrin-peptone-yeast extract (DPY) media. The alpha-amylase activity was detected in MSLC and APC in a much larger extent than that in SFC when DPY medium was used. On the basis of SDS-PAGE analyses and N-terminal amino acid sequences, 6 proteins were identified in the supernatants of the culture broths using DPY medium, among which oryzin (alkaline protease) and alpha-amylase were detected at a much higher extent for APC and MSLC than those for SFC while only oryzin was detected in mCD medium, in accordance with the activity measurements. A microarray analysis for the fungi cultivated by SFC, APC, and MSLC using mCD medium was carried out to elucidate the differences in the gene transcriptional profile by the cultivation methods. The gene transcriptional profile obtained for the MSLC sample showed a similar tendency to the APC sample while it was quite different from that for the SFC sample. Most of the genes specifically transcribed in the MSLC sample versus those in the SFC sample with a 10-fold up-regulation or higher were unknown or predicted proteins. However, transcription of oryzin gene was only slightly up-regulated in the MSLC sample and that of alpha-amylase gene, slightly down-regulated. Copyright 2009 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  14. [Studies for analyzing the prohibited ingredients such as cyproheptadine hydrochloride in cosmetics].

    PubMed

    Tokunaga, Hiroshi; Uchino, Tadashi

    2005-01-01

    Cyproheptadine hydrochloride (CH) is nominated as the prohibited ingredients in cosmetics in Japanese Pharmaceutical Affairs Act. So the analytical method for CH was investigated by HPLC. The lotion or milky lotion of 0.5 g was put into a 10-ml volumetric flask. After adding 1.0ml of CH solution at 50 microg/ml into the volumetric flask, the mixture was made up to 10ml with methanol as the test solution. Creams were procedured as follows; 0.5 g of cream was put into a 10-ml volumetric flask. After adding 1.0 ml of tetrahydrofuran into the volumetric flask, the mixture was stirred for several minutes and the ingredients of the creams were dissolved. After adding 1.0 ml of CH solution at 50 microg/ml into the volumetric flask, the mixture was made up to 10ml with methanol. This mixture was transferred to a centrifuging tube with a cap and then the tube was centrifuged for 5 minutes at 3000 rpm. The supernatant was used as the test solution. The test solution of 20 microl was analyzed by HPLC using the ODS column (CAPCELL PAK C18 column, 4.6 x 250 mm), the mixture of 1% acetic acid with 10 mmol/l sodium octanesulfonate and acetonitrile (11:9) and the detection wavelength of 286 nm. The working curve from 0.5 to 6.0 microg/ml showed a linear line between the concentrations of CH and the peak areas. There was no interference of peak of CH with the ingredients such as methylparaben, ethylparaben in the lotions, milky lotion and creams.

  15. Revisit: A Surprising Demonstration of Total Internal Reflection

    ERIC Educational Resources Information Center

    Lee, Jiwon; Cha, Yu Wha; Jung, Yeon Su; Oh, Eun Ju; Moon, Ye Lin; Kim, Jung Bog

    2016-01-01

    Melton demonstrated a surprising disappearance using total internal reflection. When he put a Florence flask filled with marbles into a water tank and looked straight down from directly above the flask, he was only able to see marbles above a certain water level. When he added more water into the tank above the top line of the marbles, all of the…

  16. The radial transmission line as a broad-band shielded exposure system for microwave irradiation of large numbers of culture flasks.

    PubMed

    Moros, E G; Straube, W L; Pickard, W F

    1999-01-01

    The problem of simultaneously exposing large numbers of culture flasks at nominally equivalent incident power densities and with good thermal control is considered, and the radial transmission line (RTL) is proposed as a solution. The electromagnetic design of this structure is discussed, and an extensively bench-tested realization is described. Referred to 1 W of net forward power, the following specific absorption rate (SAR) data were obtained: at 835.62 MHz, 16.0+/-2.5 mW/kg (mean+/-SD) with range (11-22); at 2450 MHz, 245+/-50 mW/kg with range (130-323). Radio-frequency interference from an RTL driven at roughly 100 W is so low as to be compatible with a cellular base station only 500 m distant. To avoid potential confounding by temperature differences among as many as 144 T-75 flasks distributed over 9 RTLs (six irradiates and three shams), temperature within all flasks was controlled to 37.0+/-0.3 degrees C. Experience with over two years of trouble-free operation suggests that the RTL offers a robust, logistically friendly, and environmentally satisfactory solution to the problem of large-scale in vitro experiments in bioelectromagnetics.

  17. A high efficiency stirrer for suspension cell culture with or without microcarriers.

    PubMed

    de Bruyne, N A

    1984-01-01

    The stirrer described in this paper employs "Teaspoon stirring" in which a secondary motion is superimposed on the rotation of the liquid. This secondary motion arises from the viscous drag from the wall and bottom of the flask. The culture medium is rotated by a bulb-ended rod suspended from inside the flask cap: the bulb orbits around in a circular trough formed between a central indent in the base and the rounded periphery of the base. There are no bearings and no stagnant areas. The power used to stir 4 flasks each holding 500 ml of medium is less than 2 watts. The speed is electronically controlled by a tachometer and automatically gives a smooth start and stop as well as "Interval stirring" to assist initial attachment of cells.

  18. An Innovative Very Low Thermal Power Waste Heat Recovery System for Thermal Control of Deep Space Missions: A Thermal Flask in Space

    NASA Technical Reports Server (NTRS)

    Bhandari, Pradeep

    2015-01-01

    Future missions to deep space, such as those to the outer planets (Jupiter, Saturn, etc.), which would rely on solar photovoltaic power, would need extremely large solar arrays to produce sufficient power for their operations because solar intensity is so low at those locations. Hence any additional power that would be needed for thermal control is extremely limited. Previous deep space missions like Juno (to Jupiter) required almost 200 W of electrical power for thermal control. This is prohibitively large for many future mission concepts, and leads to them needing very large solar arrays. For Saturn, where the solar flux is 1/4th the flux at Jupiter, this would entail an extremely large increase in the solar array size to accommodate the need for thermal survival power, which would be prohibitively large in size and mass, and very expensive. Hence there is a need to come up with a thermal architecture and design options that would not need such prohibitively large thermal power levels. One solution relies on harvesting the pre-existing waste heat from all the heat dissipation that would be present from operation of electronics, instruments, etc. for their own functionality. For example, for a generic Saturn mission, the various electronics would already dissipate about 200 Watts of heat that is simply "thrown away" to space from the spacecraft surfaces. The amount of thermal power that would be required for the safe thermal control of components within the spacecraft in deep space would be roughly of this magnitude for this class of spacecraft. So it makes good sense to try to harvest the waste heat and employ it to maintain the temperatures of all the components within their allowable limits. In particular, propulsion systems typically need to be kept above their freezing limits, around room temperature (15 C). Electronics needs to be kept typically above -40 C and batteries above -20 C. The next question becomes how to harvest this waste heat and direct it to the components that would need it for their survival. The proposed system utilizes a mechanically pumped, single phase fluid loop to pick up the waste heat from components attached to this loop's tubing and then directed to a thermal flask that has tubing attached to it. The thermal flask is cylindrically shaped and contains essentially all systems and components in the spacecraft within it, with the exception of the solar array, antennae, thrusters and various apertures of instruments, etc. to allow them an unobstructed view of space. Waste heat from the heat-dissipating components warms up the fluid and is carried to the flask surface and deposited on it via the fluid loop's flow. The entire flask is covered with Multi-Layered Insulation (MLI) to minimize the heat loss from the flask and allow it to remain warm. Hence the flask essentially creates a thermal environment within which the spacecraft components reside. The temperature of the components within the flask is then essentially the same as the temperature of the flask. This approach could be a very enabling feature for deep space missions. This paper describes the approach utilized for this thermal architecture, along with its mechanical and implementation aspects. Additionally it will compare and contrast this approach with the more conventional solutions utilized earlier.

  19. Cryogenic method for measuring nuclides and fission gases

    DOEpatents

    Perdue, P.T.; Haywood, F.F.

    1980-05-02

    A cryogenic method is provided for determining airborne gases and particulates from which gamma rays are emitted. A special dewar counting vessel is filled with the contents of the sampling flask which is immersed in liquid nitrogen. A vertically placed sodium-iodide or germanium-lithium gamma-ray detector is used. The device and method are of particular use in measuring and identifying the radioactive noble gases including emissions from coal-fired power plants, as well as fission gases released or escaping from nuclear power plants.

  20. Sample Collection, Analysis, and Respirator Use With Isocyanate Paints

    DTIC Science & Technology

    1990-02-01

    waterbath. 4. Acetonitrile. 6. Vials, 20-m. glass, with polypropylene-lined screw 5. Deionized water . caps. 6. Pentane. 7. Vials, 4-mK glass, with screw...Evaporator, Mini-Vap. 6 port, n, eqjivalent. sodium acetate in 1 L deionized 15. Flask, filtration, 500-mt. water . Add 1 L acetonitrile. Add 16. Funnel...methanol toie 5 mi way be stored at -21 uin the dark for at least solution. four weeks. Limit peibd of storage of samler at 6. Water , distilled. 25 *C

  1. Global emissions of the hydrofluorocarbons (HFCs) HFC-365mfc, HFC-245fa, HFC-227ea, and HFC-236fa based on atmospheric observations

    NASA Astrophysics Data System (ADS)

    Vollmer, M. K.; Miller, B. R.; Rigby, M. L.; Reimann, S.; Muhle, J.; Agage, Soge, Snu Members, Kopri Members

    2010-12-01

    We report on the atmospheric measurements and global emissions of the hydrofluorocarbons (HFCs) HFC-365mfc (CH3CH2CF2CF3, 1,1,1,3,3-pentafluorobutane), HFC-245fa (CHF2CH2CF3, 1,1,1,3,3-pentafluoropropane), HFC-227ea (CF3CHFCF3, 1,1,1,2,3,3,3-heptafluoropropane), and HFC-236fa (CF3CH2CF3, 1,1,1,3,3,3-hexafluoropropane). These measurements are from in-situ observations at stations of AGAGE (Advanced Global Atmospheric Gases Experiment) and SOGE (System for Observations of Halogenated Greenhouse Gases in Europe), and from the Korean station Gosan. We also report on flask sample measurements from the Antarctic stations King Sejong and Troll, and extend our records back to the 1970s using archived air samples of both hemispheres. All data are used in a global 12-box 2-dimensional atmospheric transport model to derive global abundances and emission estimates. All four HFCs have strongly increased in the atmosphere in recent years with growth rates at nearly 10 %, resulting in dry air mole fractions at the end of 2009 of 0.49 ppt for HFC-365mfc, 1.00 ppt for HFC-245fa, and 0.51 ppt for HFC-227ea. HFC-236fa, for which we report the first atmospheric measurements, is less abundant and has grown to 0.069 ppt at the end of 2009. Our model results show rapidly growing emissions of HFC-365mfc and HFC-245fa after 2002 but surprisingly these have now started to decline to globally 2.7 kt/yr (HFC-365mfc) and 6.1 kt/yr (HFC-245fa). On the other hand HFC-227ea and HFC-236fa show uninterrupted growth in their emissions of 2.5 kt/yr and 0.2 kt/yr at the end of 2009.

  2. Grasland Stable Isotope Flux Measurements: Three Isotopomers of Carbon Dioxide Measured by QCL Spectroscopy

    NASA Astrophysics Data System (ADS)

    Zeeman, M. J.; Tuzson, B.; Eugster, W.; Werner, R. A.; Buchmann, N.; Emmenegger, L.

    2007-12-01

    To improve our understanding of greenhouse gas dynamics of managed ecosystems such as grasslands, we not only need to investigate the effects of management (e.g., grass cuts) and weather events (e.g., rainy days) on carbon dioxide fluxes, but also need to increase the time resolution of our measurements. Thus, for the first time, we assessed respiration and assimilation fluxes with high time resolution (5Hz) stable isotope measurements at an intensively managed farmland in Switzerland (Chamau, 400m ASL). Two different methods were used to quantify fluxes of carbon dioxide and associated fluxes of stable carbon isotopes: (1) the flux gradient method, and (2) the eddy covariance method. During a week long intensive measurement campaign, we (1) measured mixing ratios of carbon dioxide isotopomers (12C16O2, 12C16O18O, 13C16O2) with a Quantum Cascade Laser (QCL, Aerodyne Inc.) spectroscope and (2) collected air samples for isotope analyses (13C/12C) and (18O/16O) of carbon dioxide by Isotope Ratio Mass Spectrometry (IRMS, Finnigan) every two hours, concurrently along a height profile (z = 0.05; 0.10; 0.31; 2.15m). In the following week, the QCL setup was used for closed-path eddy covariance flux measurement of the carbon dioxide isotopomers, with the air inlet located next to an open-path Infra Red Gas Analyzers (IRGA, LiCor 7500) used simultaneously for carbon dioxide measurements. During this second week, an area of grass inside the footprint was cut and harvested after several days. The first results of in-field continuous QCL measurements of carbon dioxide mixing ratios and their stable isotopic ratios show good agreement with IRGA measurements and isotope analysis of flask samples by IRMS. Thus, QCL spectroscopy is a very promising tool for stable isotope flux investigations.

  3. Water vapor isotopes measurements at Mauna Loa, Hawaii: Comparison of laser spectroscopy and remote sensing with traditional methods, and the need for ongoing monitoring

    NASA Astrophysics Data System (ADS)

    Noone, D.; Galewsky, J.; Sharp, Z.; Worden, J.

    2008-12-01

    The isotopic composition of water vapor (2H/1H and 18O/16 ratios) provides unique information on the transport pathways that link the water sources to regional sinks, and thus proves useful in understanding the large scale humidity budgets. Recent advances in measurement technology allow the monitoring of water vapor isotope composition in ways which has can revolutionize investigations of atmospheric hydrology. Traditional measurement of isotopic composition requires trapping of samples with either large volume vacuum flasks or by trapping liquid samples with cryogens for later analyses using mass spectrometry, and are laborious and seldom span more than just short dedicated observational periods. On the other hand, laser absorption spectroscopy can provide almost continuous and autonomous in situ measurements of isotope abundances with precision almost that of traditional mass spectrometry, and observations from spacecraft can make almost daily maps of the global isotope distributions. In October of 2008 three laser based spectrometers were deployed at the Mauna Loa Laboratory in Hawaii to make continuous measurement of the 2H and 18O abundance of free tropospheric water vapor. These results are compared with traditional measurements and with measurements from two satellite platforms. While providing field validation of the new methodologies, the data show variability which captures the transport processes in the region. The data are used to characterize the role of large scale mixing of dry air, the influence of the boundary layer and the importance of moist convection in controlling the low humidity of subtropical air near Hawaii. Although the record is short, it demonstrates the usefulness of using robust isotope measurements to understand the budgets of the most important greenhouse gas. This work motivates establishing a continuous record of isotopes measurement at baseline sites, like Mauna Loa, such that the changes in water cycle can be understood and monitored as climate changes.

  4. Water vapor isotopes measurements at Mauna Loa, Hawaii: Comparison of laser spectroscopy and remote sensing with traditional methods, and the need for ongoing monitoring

    NASA Astrophysics Data System (ADS)

    Galewsky, J.; Noone, D.; Sharp, Z.; Worden, J.

    2009-04-01

    The isotopic composition of water vapor (2H/1H and 18O/16 ratios) provides unique information on the transport pathways that link water sources to regional sinks, and thus proves useful in understanding large scale atmospheric humidity budgets. Recent advances in measurement technology allow the monitoring of water vapor isotope composition in ways which has can revolutionize investigations of atmospheric hydrology. Traditional measurement of isotopic composition requires trapping of samples with either large volume vacuum flasks or by trapping liquid samples with cryogens for later analyses using mass spectrometry, and are laborious and seldom span more than just short dedicated observational periods. On the other hand, laser absorption spectroscopy can provide almost continuous and autonomous in situ measurements of isotope abundances with precision almost that of traditional mass spectrometry, and observations from spacecraft can make almost daily maps of the global isotope distributions. In October of 2008 three laser based spectrometers were deployed at the Mauna Loa Laboratory in Hawaii to make continuous measurement of the 2H and 18O abundance of free tropospheric water vapor. These results are compared with traditional measurements and with measurements from two satellite platforms. While providing field validation of the new methodologies, the data show variability which captures the transport processes in the region. The data are used to characterize the role of large scale mixing of dry air, the influence of the boundary layer and the importance of moist convection in controlling the low humidity of subtropical air near Hawaii. Although the record is short, it demonstrates the usefulness of using robust isotope measurements to understand the budgets of the most important greenhouse gas. This work motivates establishing a continuous record of isotopes measurement at baseline sites, like Mauna Loa, such that the changes in water cycle can be understood and monitored as climate changes.

  5. Global Air Quality and Climate Impacts of Mitigating Short-lived Climate Pollution in China

    NASA Astrophysics Data System (ADS)

    Harper, K.; Unger, N.; Heyes, C.; Kiesewetter, G.; Klimont, Z.; Schoepp, W.; Wagner, F.

    2014-12-01

    China is a major emitter of harmful air pollutants, including the short-lived climate pollutants (SLCPs) and their precursors. Implementation of pollution control technologies provides a mechanism for simultaneously protecting human and ecosystem health and achieving near-term climate co-benefits; however, predicting the outcomes of technical and policy interventions is challenging because the SLCPs participate in both climate warming and cooling and share many common emission sources. Here, we present the results of a combined regional integrated assessment and global climate modeling study aimed at quantifying the near-term climate and air quality co-benefits of selective control of Chinese air pollution emissions. Results from IIASA's Greenhouse Gas - Air Pollution Interactions and Synergies (GAINS) integrated assessment model indicate that methane emission reductions make up > 75% of possible CO2-equivalent emission reductions of the SLCPs and their precursors in China in 2030. A multi-pollutant emission reduction scenario incorporating the 2030 Chinese pollution control measures with the highest potential for future climate impact is applied to the NASA ModelE2 - Yale Interactive Terrestrial Biosphere (NASA ModelE2-YIBs) global carbon - chemistry - climate model to assess the regional and long-range impacts of Chinese SLCP mitigation measures. Using model simulations that incorporate dynamic methane emissions and photosynthesis-dependent isoprene emissions, we quantify the impacts of Chinese reductions of the short-lived air pollutants on radiative forcing and on surface ozone and particulate air pollution. Present-day modeled methane mole fractions are evaluated against SCIAMACHY methane columns and NOAA ESRL/GMD surface flask measurements.

  6. 40 CFR 63.2164 - If I monitor brew ethanol, what are my monitoring installation, operation, and maintenance...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... batch averages computed from two or more data points over each 1-hour period, except during periods when... performed. During these periods, a valid hour of data shall consist of at least one data point representing... volumetric flask and place the flask on a balance. Tare the balance. Weigh 2.3670 grams of the dry (anhydrous...

  7. Development of Pattern Recognition Techniques for the Evaluation of Toxicant Impacts to Multispecies Systems

    DTIC Science & Technology

    1993-06-18

    the exception. In the Standardized Aquatic Microcosm and the Mixed Flask Culture (MFC) microcosms, multivariate analysis and clustering methods...rule rather than the exception. In the Standardized Aquatic Microcosm and the Mixed Flask Culture (MFC) microcosms, multivariate analysis and...experiments using two microcosm protocols. We use nonmetric clustering, a multivariate pattern recognition technique developed by Matthews and Heame (1991

  8. [Studies for analyzing the prohibited ingredients such as acetohexamide in cosmetics].

    PubMed

    Tokunaga, Hiroshi; Uchino, Tadashi

    2005-01-01

    Acetohexamide (AH) is nominated as the prohibited ingredients in cosmetics in Japanese Pharmaceutical Affairs Act. So the analytical method for AH was investigated by HPLC. The lotion or milky lotion of 0.5g was put into a 10-ml volumetric flask. After adding 1.0ml of AH solution at 50 microg/ml into the volumetric flask, the mixture was made up to 10ml with methanol as the testing solution. Creams were procedured as follows; 0.5 g of cream was put into a 10-ml volumetric flask. After adding 1.0ml of tetrahydrofuran into the volumetric flask, the mixture was stirred for several minutes and the ingredients of the creams were dissolved. After adding 1.0ml of AH solution at 50 microg/ml into the volumetric flask, the mixture was made up to 10ml with methanol. One milliliter of the mixture including AH at 5 microg/ml was exactly put into a test tube with a cap and then 1 ml of water and 1 ml of hexane were added. After shaking vigorously, stand for several minutes. After centrifuging, the hexane layer was eliminated and the residual mixture was used as the test solution. The testing solution of 20 microl was analyzed by HPLC using the ODS column (CAPCELL PAK C18 column, 4.6 x 250mm), the mixture of acetonitrile and 50 mmol/l phosphate buffer(pH 5.3)(3:1) and the detection wavelength of 247 nm. The working curve from 0.5 to 6.0 microg/ml showed a linear line between the concentrations of AH and the peak areas. There was no interference of peak of AH with the ingredients such as methylparaben, ethylparaben in the lotions, milky lotion and creams.

  9. Optimization of CO2 Surface Flux using GOSAT Total Column CO2: First Results for 2009-2010

    NASA Astrophysics Data System (ADS)

    Basu, S.; Houweling, S.

    2011-12-01

    Constraining surface flux estimates of CO2 using satellite measurements has been one of the long-standing goals of the atmospheric inverse modeling community. We present the first results of inverting GOSAT total column CO2 measurements for obtaining global monthly CO2 flux maps over one year (June 2009 to May 2010). We use the SRON RemoTeC retrieval of CO2 for our inversions. The SRON retrieval has been shown to have no bias when compared to TCCON total column measurements, and latitudinal gradients of the retrieved CO2 are consistent with gradients deduced from the surface flask network [Butz et al, 2011]. This makes this retrieval an ideal candidate for atmospheric inversions, which are highly sensitive to spurious gradients. Our inversion system is analogous to the CarbonTracker (CT) data assimilation system; it is initialized with the prior CO2 fluxes of CT, and uses the same atmospheric transport model, i.e., TM5. The two major differences are (a) we add GOSAT CO2 data to the inversion in addition to flask data, and (b) we use a 4DVAR optimization system instead of a Kalman filter. We compare inversions using (a) only GOSAT total column CO2 measurements, (b) only surface flask CO2 measurements, and (c) the joint data set of GOSAT and surface flask measurements. We validate GOSAT-only inversions against the NOAA surface flask network and joint inversions against CONTRAIL and other aircraft campaigns. We see that inverted fluxes from a GOSAT-only inversion are consistent with fluxes from a stations-only inversion, reaffirming the low biases in SRON retrievals. From the joint inversion, we estimate the amount of added constraints upon adding GOSAT total column measurements to existing surface layer measurements.

  10. Effects of Cultivating Conditions on the Water Soluble Polysaccharides Content of Ganoderma lucidum Mycelium in Submerged Flask Culture

    NASA Astrophysics Data System (ADS)

    Rosyida, V. T.; Hayati, S. N.; Apriyana, W.; Darsih, C.; Hernawan; Poeloengasih, C. D.

    2017-12-01

    The carcinostatic substance in Ganoderma lucidum (Fr.) Karst (Polyporaceae) is a water soluble polysaccharides (WSP) which might be useful in immunotherapy. Attempt to produce effective substances from cultured mycelia is important to carry out since solid cultivation is a time consuming and quality fluctuating. The effects of cultivating conditions on the water soluble polysaccharides content of G. Lucidum mycelium were investigated in submerged flask cultures. Culture from fruiting bodies was maintained on potato dextrose-agar slope. Slopes were inoculated and incubated at 30°C for 7 days, and stored at 4°C. The flask experiments were performed in 100 ml erlenmeyer flasks containing 20 ml of the sterilized media. Actively growing mycelia (1 piece, 5 mm X 5 mm) from a newly prepared slant culture (about 7 days incubation at 30°C) were inoculated into the flask. The pH was measured and adjusted to the desired value by addition of either 4 M HCl or 2.5 M NaOH. Incubation temperature were 20, 25, and 30°C. At the end of inoculation period (14 days) mycelium consisting of individual pellets was harvested and wash for the analysis. WSP content was analysed using phenol-sulfuric acid method. The optimal initial pH for metabolite production would depend on the culture medium. Generally, high values of pH, such as 9, negatively affect both cell growth and WSP production. The optimum temperature range for the high G. lucidum mycelium and WSP production were found to be 25 - 30 °C at pH values 5 - 7 in both of media.

  11. Efficient Manufacturing of Therapeutic Mesenchymal Stromal Cells Using the Quantum Cell Expansion System

    PubMed Central

    Hanley, Patrick J.; Mei, Zhuyong; Durett, April G.; Cabreira-Harrison, Marie da Graca; Klis, Mariola; Li, Wei; Zhao, Yali; Yang, Bing; Parsha, Kaushik; Mir, Osman; Vahidy, Farhaan; Bloom, Debra; Rice, R. Brent; Hematti, Peiman; Savitz, Sean I; Gee, Adrian P.

    2014-01-01

    Background The use of bone marrow-derived mesenchymal stromal cells (MSCs) as a cellular therapy for various diseases, such as graft-versus-host-disease, diabetes, ischemic cardiomyopathy, and Crohn's disease has produced promising results in early-phase clinical trials. However, for widespread application and use in later phase studies, manufacture of these cells needs to be cost effective, safe, and reproducible. Current methods of manufacturing in flasks or cell factories are labor-intensive, involve a large number of open procedures, and require prolonged culture times. Methods We evaluated the Quantum Cell Expansion system for the expansion of large numbers of MSCs from unprocessed bone marrow in a functionally closed system and compared the results to a flask-based method currently in clinical trials. Results After only two passages, we were able to expand a mean of 6.6×108 MSCs from 25 mL of bone marrow reproducibly. The mean expansion time was 21 days, and cells obtained were able to differentiate into all three lineages: chondrocytes, osteoblasts, and adipocytes. The Quantum was able to generate the target cell number of 2.0×108 cells in an average of 9-fewer days and in half the number of passages required during flask-based expansion. We estimated the Quantum would involve 133 open procedures versus 54,400 in flasks when manufacturing for a clinical trial. Quantum-expanded MSCs infused into an ischemic stroke rat model were therapeutically active. Discussion The Quantum is a novel method of generating high numbers of MSCs in less time and at lower passages when compared to flasks. In the Quantum, the risk of contamination is substantially reduced due to the substantial decrease in open procedures. PMID:24726657

  12. Trophic interactions in the plankton of Malyi Sevan in July, 1984

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gulelmacher, B.L.; Simonyan, A.A.

    1986-09-01

    This paper describes some studies of the trophic interactions in the plankton in Lchashenskaya Bay in Malyi Sevan in July, 1984. The goal was to study the feeding characteristics of the major crustacean species and their influence on the phytoplankton. To study the effect of the planktonic crustaceans on the phytoplankton, a flask with an added 50 Acanthodiaptomus and a flask without crustaceans were exposed for 24 h after which a radioactive carbon isotope was added to them in the form of sodium carbonate. The radioactivity of the filters and working solutions was measured and autoradiographic preparations were made. Itmore » is shown that the more than threefold drop in the quantity of algae in a flask resulting from crustacean feeding did not lead to a significant decrease in primary production.« less

  13. Bioleaching of electronic scrap by mixed culture of moderately thermophilic microorganisms

    NASA Astrophysics Data System (ADS)

    Ivǎnuş, D.; ǎnuş, R. C., IV; Cǎlmuc, F.

    2010-06-01

    A process for the metal recovery from electronic scrap using bacterial leaching was investigated. A mixed culture of moderately thermophilic microorganisms was enriched from acid mine drainages (AMDs) samples collected from several sulphide mines in Romania, and the bioleaching of electronic scrap was conducted both in shake flask and bioreactor. The results show that in the shake flask, the mixture can tolerate 50 g/L scrap after being acclimated to gradually increased concentrations of scrap. The copper extraction increases obviously in bioleaching of scrap with moderately thermophilic microorganisms supplemented with 0.4 g/L yeast extract at 180 r/min, 74% copper can be extracted in the pulp of 50 g/L scrap after 20 d. Compared with copper extractions of mesophilic culture, unacclimated culture and acclimated culture without addition of yeast extract, that of accliniated culture with addition of yeast extract is increased by 53%, 44% and 16%, respectively. In a completely stirred tank reactor, the mass fraction of copper and total iron extraction reach up to 81% and 56%, respectively. The results also indicate that it is necessary to add a large amount of acid to the pulp to extract copper from electronic scrap effectively.

  14. Biodegradation of low-density polyethylene (LDPE) by isolated fungi in solid waste medium.

    PubMed

    Zahra, Sahebnazar; Abbas, Shojaosadati Seyed; Mahsa, Mohammad-Taheri; Mohsen, Nosrati

    2010-03-01

    In this study, biodegradation of low-density polyethylene (LDPE) by isolated landfill-source fungi was evaluated in a controlled solid waste medium. The fungi, including Aspergillus fumigatus, Aspergillus terreus and Fusarium solani, were isolated from samples taken from an aerobic aged municipal landfill in Tehran. These fungi could degrade LDPE via the formation of a biofilm in a submerged medium. In the sterilized solid waste medium, LPDE films were buried for 100 days in a 1-L flask containing 400 g sterile solid waste raw materials at 28 degrees C. Each fungus was added to a separate flask. The moisture content and pH of the media were maintained at the optimal levels for each fungus. Photo-oxidation (25 days under UV-irradiation) was used as a pretreatment of the LDPE samples. The progress of the process was monitored by measurement of total organic carbon (TOC), pH, temperature and moisture. The results obtained from monitoring the process using isolated fungi under sterile conditions indicate that these fungi are able to grow in solid waste medium. The results of FT-IR and SEM analyses show that A. terreus and A. fumigatus, despite the availability of other organic carbon of materials, could utilize LDPE as carbon source. While there has been much research in the field of LDPE biodegradation under solid conditions, this is the first report of degradation of LDPE by A. fumigatus. Copyright 2009 Elsevier Ltd. All rights reserved.

  15. Biodegradation of low-density polyethylene (LDPE) by isolated fungi in solid waste medium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zahra, Sahebnazar; Abbas, Shojaosadati Seyed, E-mail: sa_shoja@modares.ac.i; Mahsa, Mohammad-Taheri

    In this study, biodegradation of low-density polyethylene (LDPE) by isolated landfill-source fungi was evaluated in a controlled solid waste medium. The fungi, including Aspergillus fumigatus, Aspergillus terreus and Fusarium solani, were isolated from samples taken from an aerobic aged municipal landfill in Tehran. These fungi could degrade LDPE via the formation of a biofilm in a submerged medium. In the sterilized solid waste medium, LPDE films were buried for 100 days in a 1-L flask containing 400 g sterile solid waste raw materials at 28 deg. C. Each fungus was added to a separate flask. The moisture content and pHmore » of the media were maintained at the optimal levels for each fungus. Photo-oxidation (25 days under UV-irradiation) was used as a pretreatment of the LDPE samples. The progress of the process was monitored by measurement of total organic carbon (TOC), pH, temperature and moisture. The results obtained from monitoring the process using isolated fungi under sterile conditions indicate that these fungi are able to grow in solid waste medium. The results of FT-IR and SEM analyses show that A. terreus and A. fumigatus, despite the availability of other organic carbon of materials, could utilize LDPE as carbon source. While there has been much research in the field of LDPE biodegradation under solid conditions, this is the first report of degradation of LDPE by A. fumigatus.« less

  16. Determination of the δ2H and δ18O of soil water and water in plant matter; RSIL lab code 1700

    USGS Publications Warehouse

    Revesz, Kinga M.; Buck, Bryan; Coplen, Tyler B.

    2012-01-01

    The purpose of the Reston Stable Isotope Laboratory lab code 1700 is to determine the δ2H/1H), abbreviated as δ2H, and the δ18O/16O), abbreviated as δ18O, of soil water and water in plant matter. This method is based on the observation that water and toluene form an azeotropic mixture at 84.1 °C. This temperature is substantially lower than the boiling points of water (100 °C) and toluene (110 °C), but water and toluene are immiscible at ambient temperature. The water content of a soil or plant is determined by weighing, drying, and reweighing a small amount of sample. Sufficient sample to collect 3 to 5 milliliters of water after distillation is loaded into a distillation flask. Sufficient toluene is added so that the sample is immersed throughout the entire distillation to minimize evaporation of water, which would affect the δ2H and δ18O values. The mixture of sample and toluene is heated in a flask to its boiling point (84.1 °C) so that water from the sample and toluene can distill together into a specially designed collection funnel. The temperature of 84.1 °C is maintained until the water has been quantitatively transferred to the collection funnel, at which time the temperature is raised to the boiling point of the remaining component (toluene, 110 °C). The collection funnel is maintained at ambient temperature so that the sample water and toluene can be separated physically. After separation, the sample water is purified by addition of paraffin wax to the container with the sample water, capping the container, and heating to approximately 60 °C to melt the wax. Trace amounts of toluene will dissolve in the wax, purifying the sample water for isotopic analysis. The isotopic composition of the purified water is then determined by equilibration with gaseous hydrogen or carbon dioxide, followed by dual-inlet isotope-ratio mass spectrometry. Because laser-absorption spectrometry is sensitive to organic compounds, such as trace toluene remaining in water samples, water samples should be analyzed for isotopic composition only by mass spectrometry and not by laser-absorption spectrometry.

  17. The Flask Security Architecture: System Support for Diverse Security Policies

    DTIC Science & Technology

    2006-01-01

    Flask microkernel -based operating sys­ tem, that successfully overcomes these obstacles to pol- icy flexibility. The cleaner separation of mechanism and...other object managers in the system to en- force those access control decisions. Although the pro­ totype system is microkernel -based, the security...mecha­ nisms do not depend on a microkernel architecture and will easily generalize beyond it. The resulting system provides policy flexibility. It sup

  18. Comparison of a 50 mL pycnometer and a 500 mL flask, EURAMET.M.FF.S8 (EURAMET 1297)

    NASA Astrophysics Data System (ADS)

    Mićić, Ljiljana; Batista, Elsa

    2018-01-01

    The purpose of this comparison was to compare the results of the participating laboratories in the calibration of 50 mL pycnometer and 500 mL volumetric flask using the gravimetric method. Laboratories were asked to determined the 'contained' volume of the 50 mL pycnometer and of the 500 mL flask at a reference temperature of 20 °C. The gravimetric method was used for both instruments by all laboratories. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Biofilm lifestyle enhances diesel bioremediation and biosurfactant production in the Antarctic polyhydroxyalkanoate producer Pseudomonas extremaustralis.

    PubMed

    Tribelli, Paula M; Di Martino, Carla; López, Nancy I; Raiger Iustman, Laura J

    2012-09-01

    Diesel is a widely distributed pollutant. Bioremediation of this kind of compounds requires the use of microorganisms able to survive and adapt to contaminated environments. Pseudomonas extremaustralis is an Antarctic bacterium with a remarkable survival capability associated to polyhydroxyalkanoates (PHAs) production. This strain was used to investigate the effect of cell growth conditions--in biofilm versus shaken flask cultures--as well as the inocula characteristics associated with PHAs accumulation, on diesel degradation. Biofilms showed increased cell growth, biosurfactant production and diesel degradation compared with that obtained in shaken flask cultures. PHA accumulation decreased biofilm cell attachment and enhanced biosurfactant production. Degradation of long-chain and branched alkanes was observed in biofilms, while in shaken flasks only medium-chain length alkanes were degraded. This work shows that the PHA accumulating bacterium P. extremaustralis can be a good candidate to be used as hydrocarbon bioremediation agent, especially in extreme environments.

  20. Use of saline waste water from demineralization of cheese whey for cultivation of Schizochytrium limacinum PA-968 and Japonochytrium marinum AN-4.

    PubMed

    Humhal, Tomas; Kastanek, Petr; Jezkova, Zuzana; Cadkova, Anna; Kohoutkova, Jana; Branyik, Tomas

    2017-03-01

    Saline waste water from demineralization of cheese whey was used as the main component of waste saline medium (WSM) for cultivation of thraustochytrids. The suitability of WSM for cultivation of Schizochytrium limacinum PA-968 and Japonochytrium marinum AN-4 was evaluated by comparison with cultivation on nutrient medium (NM) in shake flask and fermenter cultures. Biomass productivities achieved in WSM for the thraustochytrids were comparable with those in NM for both shake flask and fermenter cultures. The maximum total lipid content (56.71% dry cell weight) and docosahexaenoic acid productivity (0.86 g/L/day) were achieved by J. marinum AN-4 grown on WSM in shake flask and fermenter cultures, respectively. A cost estimate of WSM suggests that this medium could result in lower production costs for thraustochytrid biomass and lipids and contribute to the effective reduction in saline diary process waste water.

  1. A portable molecular-sieve-based CO2 sampling system for radiocarbon measurements

    NASA Astrophysics Data System (ADS)

    Palonen, V.

    2015-12-01

    We have developed a field-capable sampling system for the collection of CO2 samples for radiocarbon-concentration measurements. Most target systems in environmental research are limited in volume and CO2 concentration, making conventional flask sampling hard or impossible for radiocarbon studies. The present system captures the CO2 selectively to cartridges containing 13X molecular sieve material. The sampling does not introduce significant under-pressures or significant losses of moisture to the target system, making it suitable for most environmental targets. The system also incorporates a significantly larger sieve container for the removal of CO2 from chambers prior to the CO2 build-up phase and sampling. In addition, both the CO2 and H2O content of the sample gas are measured continuously. This enables in situ estimation of the amount of collected CO2 and the determination of CO2 flux to a chamber. The portable sampling system is described in detail and tests for the reliability of the method are presented.

  2. A portable molecular-sieve-based CO2 sampling system for radiocarbon measurements.

    PubMed

    Palonen, V

    2015-12-01

    We have developed a field-capable sampling system for the collection of CO2 samples for radiocarbon-concentration measurements. Most target systems in environmental research are limited in volume and CO2 concentration, making conventional flask sampling hard or impossible for radiocarbon studies. The present system captures the CO2 selectively to cartridges containing 13X molecular sieve material. The sampling does not introduce significant under-pressures or significant losses of moisture to the target system, making it suitable for most environmental targets. The system also incorporates a significantly larger sieve container for the removal of CO2 from chambers prior to the CO2 build-up phase and sampling. In addition, both the CO2 and H2O content of the sample gas are measured continuously. This enables in situ estimation of the amount of collected CO2 and the determination of CO2 flux to a chamber. The portable sampling system is described in detail and tests for the reliability of the method are presented.

  3. Environmental Consequences of Nanotechnologies: Nanoparticle Dispersion in Aqueous Media: SOP-T-1

    DTIC Science & Technology

    2015-02-01

    containing ice • Bath sonicator • Weighing dish (aluminum) • Stainless steel spatula • Analytical balance • Lab jack for lifting sample • Volumetric...balance and an aluminum dish, weigh an adequate mass of dry powder under a fume hood to achieve the desired concentration into ultrapure water (<T>, <R...0.025 0.5 0.05 1 0.5 10 1 20 2. Add ultra-pure water in a glass beaker with NP powder to /flask under fume hood (<T>, <R>). 3. Degas the bath

  4. Decomposition of aquatic plants in lakes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Godshalk, G.L.

    1977-01-01

    This study was carried out to systematically determine the effects of temperature and oxygen concentration, two environmental parameters crucial to lake metabolism in general, on decomposition of five species of aquatic vascular plants of three growth forms in a Michigan lake. Samples of dried plant material were decomposed in flasks in the laboratory under three different oxygen regimes, aerobic-to-anaerobic, strict anaerobic, and aerated, each at 10/sup 0/C and 25/sup 0/C. In addition, in situ decomposition of the same species was monitored using the litter bag technique under four conditions.

  5. Navigation and vessel inspection circular No. 3-94. International maritime organization code for the safe carriage of irradiated nuclear fuel, plutonium and high-level radioactive wastes in flasks on board ships (IMO resolution a.748(18)). Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1994-05-26

    The Circular calls the attention of Coast Guard field units, marine surveyors, shippers and carriers of nuclear materials to the International Maritime Organization (IMO) Code for the Safe Carriage of Irradiated Nuclear Fuel, Plutonium and High-Level Radioactive Wastes in Flasks on Board Ships (IMO Resolution A.748(18)).

  6. Application of an Online-Biomass Sensor in an Optical Multisensory Platform Prototype for Growth Monitoring of Biotechnical Relevant Microorganism and Cell Lines in Single-Use Shake Flasks

    PubMed Central

    Ude, Christian; Schmidt-Hager, Jörg; Findeis, Michael; John, Gernot Thomas; Scheper, Thomas; Beutel, Sascha

    2014-01-01

    In the context of this work we evaluated a multisensory, noninvasive prototype platform for shake flask cultivations by monitoring three basic parameters (pH, pO2 and biomass). The focus lies on the evaluation of the biomass sensor based on backward light scattering. The application spectrum was expanded to four new organisms in addition to E. coli K12 and S. cerevisiae [1]. It could be shown that the sensor is appropriate for a wide range of standard microorganisms, e.g., L. zeae, K. pastoris, A. niger and CHO-K1. The biomass sensor signal could successfully be correlated and calibrated with well-known measurement methods like OD600, cell dry weight (CDW) and cell concentration. Logarithmic and Bleasdale-Nelder derived functions were adequate for data fitting. Measurements at low cell concentrations proved to be critical in terms of a high signal to noise ratio, but the integration of a custom made light shade in the shake flask improved these measurements significantly. This sensor based measurement method has a high potential to initiate a new generation of online bioprocess monitoring. Metabolic studies will particularly benefit from the multisensory data acquisition. The sensor is already used in labscale experiments for shake flask cultivations. PMID:25232914

  7. pH measurement and a rational and practical pH control strategy for high throughput cell culture system.

    PubMed

    Zhou, Haiying; Purdie, Jennifer; Wang, Tongtong; Ouyang, Anli

    2010-01-01

    The number of therapeutic proteins produced by cell culture in the pharmaceutical industry continues to increase. During the early stages of manufacturing process development, hundreds of clones and various cell culture conditions are evaluated to develop a robust process to identify and select cell lines with high productivity. It is highly desirable to establish a high throughput system to accelerate process development and reduce cost. Multiwell plates and shake flasks are widely used in the industry as the scale down model for large-scale bioreactors. However, one of the limitations of these two systems is the inability to measure and control pH in a high throughput manner. As pH is an important process parameter for cell culture, this could limit the applications of these scale down model vessels. An economical, rapid, and robust pH measurement method was developed at Eli Lilly and Company by employing SNARF-4F 5-(-and 6)-carboxylic acid. The method demonstrated the ability to measure the pH values of cell culture samples in a high throughput manner. Based upon the chemical equilibrium of CO(2), HCO(3)(-), and the buffer system, i.e., HEPES, we established a mathematical model to regulate pH in multiwell plates and shake flasks. The model calculates the required %CO(2) from the incubator and the amount of sodium bicarbonate to be added to adjust pH to a preset value. The model was validated by experimental data, and pH was accurately regulated by this method. The feasibility of studying the pH effect on cell culture in 96-well plates and shake flasks was also demonstrated in this study. This work shed light on mini-bioreactor scale down model construction and paved the way for cell culture process development to improve productivity or product quality using high throughput systems. Copyright 2009 American Institute of Chemical Engineers

  8. Cytogenetic studies in human blood lymphocytes exposed in vitro to radiofrequency radiation at a cellular telephone frequency (835.62 MHz, FDMA).

    PubMed

    Vijayalaxmi; Leal, B Z; Meltz, M L; Pickard, W F; Bisht, K S; Roti Roti JL; Straube, W L; Moros, E G

    2001-01-01

    Freshly collected peripheral blood samples from four healthy human volunteers were diluted with RPMI 1640 tissue culture medium and exposed in sterile T-75 tissue culture flasks in vitro for 24 h to 835.62 MHz radiofrequency (RF) radiation, a frequency employed for customer-to-base station transmission of cellular telephone communications. An analog signal was used, and the access technology was frequency division multiple access (FDMA, continuous wave). A nominal net forward power of 68 W was used, and the nominal power density at the center of the exposure flask was 860 W/m(2). The mean specific absorption rate in the exposure flask was 4.4 or 5.0 W/kg. Aliquots of diluted blood that were sham-exposed or exposed in vitro to an acute dose of 1.50 Gy of gamma radiation were used as negative or positive controls. Immediately after the exposures, the lymphocytes were stimulated with a mitogen, phytohemagglutinin, and cultured for 48 or 72 h to determine the extent of genetic damage, as assessed from the frequencies of chromosomal aberrations and micronuclei. The extent of alteration in the kinetics of cell proliferation was determined from the mitotic indices in 48-h cultures and from the incidence of binucleate cells in 72-h cultures. The data indicated no significant differences between RF-radiation- and sham-exposed lymphocytes with respect to mitotic indices, incidence of exchange aberrations, excess fragments, binucleate cells, and micronuclei. In contrast, the response of the lymphocytes exposed to gamma radiation was significantly different from both RF-radiation- and sham-exposed cells for all of these indices. Thus, under the experimental conditions tested, there is no evidence for the induction of chromosomal aberrations and micronuclei in human blood lymphocytes exposed in vitro for 24 h to 835.62 MHz RF radiation at SARs of 4.4 or 5.0 W/kg.

  9. Boiling point measurement of a small amount of brake fluid by thermocouple and its application.

    PubMed

    Mogami, Kazunari

    2002-09-01

    This study describes a new method for measuring the boiling point of a small amount of brake fluid using a thermocouple and a pear shaped flask. The boiling point of brake fluid was directly measured with an accuracy that was within approximately 3 C of that determined by the Japanese Industrial Standards method, even though the sample volume was only a few milliliters. The method was applied to measure the boiling points of brake fluid samples from automobiles. It was clear that the boiling points of brake fluid from some automobiles dropped to approximately 140 C from about 230 C, and that one of the samples from the wheel cylinder was approximately 45 C lower than brake fluid from the reserve tank. It is essential to take samples from the wheel cylinder, as this is most easily subjected to heating.

  10. Application of multivariate analysis and mass transfer principles for refinement of a 3-L bioreactor scale-down model--when shake flasks mimic 15,000-L bioreactors better.

    PubMed

    Ahuja, Sanjeev; Jain, Shilpa; Ram, Kripa

    2015-01-01

    Characterization of manufacturing processes is key to understanding the effects of process parameters on process performance and product quality. These studies are generally conducted using small-scale model systems. Because of the importance of the results derived from these studies, the small-scale model should be predictive of large scale. Typically, small-scale bioreactors, which are considered superior to shake flasks in simulating large-scale bioreactors, are used as the scale-down models for characterizing mammalian cell culture processes. In this article, we describe a case study where a cell culture unit operation in bioreactors using one-sided pH control and their satellites (small-scale runs conducted using the same post-inoculation cultures and nutrient feeds) in 3-L bioreactors and shake flasks indicated that shake flasks mimicked the large-scale performance better than 3-L bioreactors. We detail here how multivariate analysis was used to make the pertinent assessment and to generate the hypothesis for refining the existing 3-L scale-down model. Relevant statistical techniques such as principal component analysis, partial least square, orthogonal partial least square, and discriminant analysis were used to identify the outliers and to determine the discriminatory variables responsible for performance differences at different scales. The resulting analysis, in combination with mass transfer principles, led to the hypothesis that observed similarities between 15,000-L and shake flask runs, and differences between 15,000-L and 3-L runs, were due to pCO2 and pH values. This hypothesis was confirmed by changing the aeration strategy at 3-L scale. By reducing the initial sparge rate in 3-L bioreactor, process performance and product quality data moved closer to that of large scale. © 2015 American Institute of Chemical Engineers.

  11. The Influence of Ecological Isolation on the Structural and Functional Stability of Complex Microbial Communities

    NASA Technical Reports Server (NTRS)

    Franklin, R. B.; Garland, J. L.; Mills, A. L.

    2005-01-01

    To help understand how the behavior of microorganisms and microbial communities in insular space habitats may differ from the behavior of these groups on Earth, long-term incubations (100+ days) were conducting using wastewater bioreactors (batch fed) designed to mimic "closed" and "open" ecological systems. The issue of immigration was considered, and the goal of the research was to determine whether the stability of microbial communities in space is reduced due to their prolonged isolation. Bioreactors were established by inoculating flasks of sterile synthetic wastewater with the microbial community obtained from a local treatment facility; each day, one-third of the medium in the flask was replaced with an equal volume of sterile artificial wastewater. Flasks were divided into two treatments: "closed" and "open" to recruitment of additional microorganisms. "Closed" flasks were maintained as described above, while the medium used to feed the "open" flasks was supplemented daily with a small amount of raw sewage (which provided a continuous source of new potential community members). Significant differences in microbial community structure and function developed in the two sets of communities, and the results suggest that the open community was more stable and better able to adjust to changing environmental conditions. Each community's resistance to environmental (temperature fluctuations) and biological stresses (starvation and invasion by an opportunistic pathogen Pseudomonas aeruginosa) was monitored. Experiments were also conducted to determine whether the effect of isolation changes depending on the microbial communities' initial diversity or composition; communities with a low(er) initial diversity were less stable. Overall, the results indicate that isolation will be an important factor influencing the activity of microbial communities on board spacecraft. A possible way of mitigating these effects would be to include communities with high initial diversity or to periodically re-inoculate the systems using diverse inocula transported from Earth.

  12. Advances in High Energy Solid-State Pulsed 2-Micron Lidar Development for Ground and Airborne Wind, Water Vapor and CO2 Measurements

    NASA Technical Reports Server (NTRS)

    Singh, Upendra N.; Yu, Jirong; Petros, Mulugeta; Refaat, Tamer; Kavaya, Michael J.; Remus, Ruben

    2015-01-01

    NASA Langley Research Center has a long history of developing 2-micron lasers. From fundamental spectroscopy research, theoretical prediction of new materials, laser demonstration and engineering of lidar systems, it has been a very successful program spanning around two decades. Successful development of 2-micron lasers has led to development of a state-of-the-art compact lidar transceiver for a pulsed coherent Doppler lidar system for wind measurement with an unprecedented laser pulse energy of 250 millijoules in a rugged package. This high pulse energy is produced by a Ho:Tm:LuLiF laser with an optical amplifier. While the lidar is meant for use as an airborne instrument, ground-based tests were carried out to characterize performance of the lidar. Atmospheric measurements will be presented, showing the lidar's capability for wind measurement in the atmospheric boundary layer and free troposphere. Lidar wind measurements are compared to a balloon sonde, showing good agreement between the two sensors. Similar architecture has been used to develop a high energy, Ho:Tm:YLF double-pulsed 2-micron Integrated Differential Absorption Lidar (IPDA) instrument based on direct detection technique that provides atmospheric column CO2 measurements. This instrument has been successfully used to measure atmospheric CO2 column density initially from a ground mobile lidar trailer, and then it was integrated on B-200 plane and 20 hours of flight measurement were made from an altitude ranging 1500 meters to 8000 meters. These measurements were compared to in-situ measurements and National Oceanic and Atmospheric Administration (NOAA) airborne flask measurement to derive the dry mixing ratio of the column CO2 by reflecting the signal by various reflecting surfaces such as land, vegetation, ocean surface, snow and sand. The lidar measurements when compared showed a very agreement with in-situ and airborne flask measurement. NASA Langley Research Center is currently developing a triple-pulsed 2-micron Integrated Differential Absorption Lidar (IPDA) instrument for simultaneous measurement of water vapor and carbon-dioxide column density measurement from an air-borne platform. This presentation will give an overview of the 2 decades of 2-micron coherent and direction detection of laser/lidar development at NASA Langley Research Center and will present the ground and airborne wind and column CO2 measurement intercomparison with in-situ, balloon and flask measurements.

  13. Chemistries for Protection and Decontamination

    DTIC Science & Technology

    2008-03-01

    t i o n Measurement of Oxygen Uptake, Supported Catalyst and CEES in Solvent-Free System TDA R e s e a r c h Tests with HD • At CUBRC (Buffalo...dual gas burettes for HD tests at CUBRC . The dual burette on the left was connected to a flask with the catalyst and HD (and to an empty flask as a...Hill, Zhen Luo, Daniel Hillesheim • ECBC: Larry Procell • CUBRC : Meg Stapleton, Rich Fitzpatrick • Battelle: John Ontiveros, Walter Miller • ARO

  14. Can the Short-Term Toxicity of Water-Soluble Jet Fuel Hydrocarbons Produce Long-Lasting Effects in Lake Plankton Communities?

    DTIC Science & Technology

    1983-09-01

    Richard Starr Algal collection or Ankistrodesmus sp. or Chlorella sp. from the Carolina Biological collection. The cultures were unialgal but not... Chlorella were grown in BBM medium. After five days ot growth, half ot the flasks (3) for each species were spiked with 0.1 ml of toluene. The , .. flasks...quickly recovered and grew at rates equa’ the = toluene-free cells, finally reaching the same final biomass. Ankistrodesmus and Chlorella however

  15. Tunable diode laser in-situ CH4 measurements aboard the CARIBIC passenger aircraft: instrument performance assessment

    NASA Astrophysics Data System (ADS)

    Dyroff, C.; Zahn, A.; Sanati, S.; Christner, E.; Rauthe-Schöch, A.; Schuck, T. J.

    2013-10-01

    A laser spectrometer for automated monthly measurements of methane (CH4) mixing ratios aboard the CARIBIC passenger aircraft is presented. The instrument is based on a commercial Fast Greenhouse Gas Analyzer (FGGA, Los Gatos Res.), which was adapted to meet the requirements imposed by unattended airborne employment. The modified instrument is described. A laboratory characterization was performed to determine the instrument stability, precision, cross sensitivity to H2O, and accuracy. For airborne operation a calibration strategy is described, that utilizes CH4 measurements obtained from flask samples taken during the same flights. The precision of airborne measurements is 2 ppbv for 10 s averages. The accuracy at aircraft cruising altitude is 3.85 ppbv. During aircraft ascent and descent, where no flask samples were obtained, instrumental drifts can be less accurately considered and the uncertainty is estimated to be 12.4 ppbv. A linear humidity bias correction was applied to the CH4 measurements, which was most important in the lower troposphere. On average, the correction bias was around 6.5 ppbv at an altitude of 2 km, and negligible at cruising flight level. Observations from 103 long-distance flights are presented that span a large part of the northern hemispheric upper troposphere and lowermost stratosphere (UT/LMS), with occasional crossing of the tropics on flights to southern Africa. These accurate data mark the largest UT/LMS in-situ CH4 dataset worldwide. An example of a tracer-tracer correlation study with ozone is given, highlighting the possibility for accurate cross-tropopause transport analyses.

  16. Tunable diode laser in-situ CH4 measurements aboard the CARIBIC passenger aircraft: instrument performance assessment

    NASA Astrophysics Data System (ADS)

    Dyroff, C.; Zahn, A.; Sanati, S.; Christner, E.; Rauthe-Schöch, A.; Schuck, T. J.

    2014-03-01

    A laser spectrometer for automated monthly measurements of methane (CH4) mixing ratios aboard the CARIBIC passenger aircraft is presented. The instrument is based on a commercial Fast Greenhouse Gas Analyser (FGGA, Los Gatos Res.), which was adapted to meet the requirements imposed by unattended airborne operation. It was characterised in the laboratory with respect to instrument stability, precision, cross sensitivity to H2O, and accuracy. For airborne operation, a calibration strategy is described that utilises CH4 measurements obtained from flask samples taken during the same flights. The precision of airborne measurements is 2 ppb for 10 s averages. The accuracy at aircraft cruising altitude is 3.85 ppb. During aircraft ascent and descent, where no flask samples were obtained, instrumental drifts can be less accurately determined and the uncertainty is estimated to be 12.4 ppb. A linear humidity bias correction was applied to the CH4 measurements, which was most important in the lower troposphere. On average, the correction bias was around 6.5 ppb at an altitude of 2 km, and negligible at cruising flight level. Observations from 103 long-distance flights are presented that span a large part of the northern hemispheric upper troposphere and lowermost stratosphere (UT/LMS), with occasional crossing of the tropics on flights to southern Africa. These accurate data mark the largest UT/LMS in-situ CH4 dataset worldwide. An example of a tracer-tracer correlation study with ozone is given, highlighting the possibility for accurate cross-tropopause transport analyses.

  17. Quantitative analysis of the growth of Salmonella stanley during alfalfa sprouting and evaluation of Enterobacter aerogenes as its surrogate.

    PubMed

    Liu, Bin; Schaffner, Donald W

    2007-02-01

    Raw seed sprouts have been implicated in several food poisoning outbreaks in the last 10 years. Few studies have included investigations of factors influencing the effectiveness of testing spent irrigation water, and in no studies to date has a nonpathogenic surrogate been identified as suitable for large-scale irrigation water testing trials. Alfalfa seeds were inoculated with Salmonella Stanley or its presumptive surrogate (nalidixic acid-resistant Enterobacter aerogenes) at three concentrations (-3, -30, and -300 CFU/g) and were then transferred into either flasks or a bench top-scale sprouting chamber. Microbial concentrations were determined in seeds, sprouts, and irrigation water at various times during a 4-day sprouting process. Data were fit to logistic regression models, and growth rates and maximum concentrations were compared using the generalized linear model procedure of SAS. No significant differences in growth rates were observed among samples taken from flasks or the chamber. Microbial concentrations in irrigation water were not significantly different from concentrations in sprout samples obtaihed at the same time. E. aerogenes concentrations were similar to those of Salmonella Stanley at corresponding time points for all three inoculum concentrations. Growth rates were also constant regardless of inoculum concentration or strain, except that lower inoculum concentrations resulted in lower final concentrations proportional to their initial concentrations. This research demonstrated that a nonpathogenic easy-to-isolate surrogate (nalidixic acid-resistant E. aerogenes) provides results similar to those obtained with Salmonella Stanley, supporting the use of this surrogate in future large-scale experiments.

  18. EPA Method 1615. Measurement of Enterovirus and Norovirus ...

    EPA Pesticide Factsheets

    A standardized method is required when national studies on virus occurrence in environmental and drinking waters utilize multiple analytical laboratories. The U.S Environmental Protection Agency’s (USEPA) Method 1615 was developed with the goal of providing such a standard for measuring Enterovirus and Norovirus in these waters. Virus is concentrated from water using an electropositive filter, eluted from the filter surface with beef extract, and then concentrated further using organic flocculation. Herein we present the protocol from Method 1615 for filter elution, secondary concentration, and measurement of total culturable viruses. A portion of the concentrated eluate from each sample is inoculated onto ten replicate flasks of Buffalo Green Monkey kidney cells. The number of flasks demonstrating cytopathic effects is used to quantify the most probable number (MPN) of infectious units per liter. The method uses a number of quality controls to increase data quality and to reduce interlaboratory and intralaboratory variation. Laboratories must meet defined performance standards. Method 1615 was evaluated by examining virus recovery from reagent-grade and ground waters seeded with Sabin poliovirus type 3. Mean poliovirus recoveries with the total culturable assay were 111% in reagent grade water and 58% in groundwaters. EPA Method 1615 is being used by a number of national and international labs. This paper and the accompanying video will provide training oppo

  19. Emission of atmospheric pollutants out of Africa - Analysis of CARIBIC aircraft air samples

    NASA Astrophysics Data System (ADS)

    Thorenz, Ute R.; Baker, Angela K.; Schuck, Tanja; van Velthoven, Peter F. J.; Ziereis, Helmut; Brenninkmeijer, Carl A. M.

    2014-05-01

    Africa is the single largest continental source of biomass burning (BB) emissions. The burning African savannas and tropical forests are a source for a wide range of chemical species, which are important for global atmospheric chemistry, especially for the pristine Southern Hemisphere. Emitted compounds include carbon monoxide (CO), nitrogen oxides (NOx), hydrocarbons, oxygenated hydrocarbons and particles. Deep convection over Central Africa transports boundary layer emissions to the free troposphere making aircraft-based observations useful for investigation of surface emissions and examination of transport and chemistry processes over Africa The CARIBIC project (Civil Aircraft for the Regular Investigation of the Atmosphere Based on an Instrument Container, www.caribic-atmosphere.com part of IAGOS www.iagos.org) is a long term atmospheric measurement program using an instrument container deployed aboard a Lufthansa Airbus A340-600 for a monthly sequence of long-distance passenger flights. Besides the online measurements mixing ratios of greenhouse gases and a suite of C2-C8 non methane hydrocarbons (NMHCs) are measured from flask samples collected at cruise altitude. During northern hemispheric winter 2010/2011 CARIBIC flights took place from Frankfurt to Cape Town and Johannesburg in South Africa. Several BB tracers like methane, CO and various NMHCs were found to be elevated over tropical Africa. Using tracer-CO- and tracer-NOy-correlations emissions were characterized. The NMHC-CO correlations show monthly changing slopes, indicating a change in burned biomass, major fire stage, source region and/or other factors influencing NMHC emissions. To expand our analysis of emission sources a source region data filter was used, based on backward trajectories calculated along the flight tracks. Taking all CARIBIC samples into account having backward trajectories to the African boundary layer the dataset was enlarged from 77 to 168 samples. For both datasets tracer-tracer correlations are used to investigate sources and the correlations between NMHCs are used to analyze photochemical processing and transport.

  20. Shear stress enhances microcin B17 production in a rotating wall bioreactor, but ethanol stress does not

    NASA Technical Reports Server (NTRS)

    Gao, Q.; Fang, A.; Pierson, D. L.; Mishra, S. K.; Demain, A. L.

    2001-01-01

    Stress, including that caused by ethanol, has been shown to induce or promote secondary metabolism in a number of microbial systems. Rotating-wall bioreactors provide a low stress and simulated microgravity environment which, however, supports only poor production of microcin B17 by Escherichia coli ZK650, as compared to production in agitated flasks. We wondered whether the poor production is due to the low level of stress and whether increasing stress in the bioreactors would raise the amount of microcin B17 formed. We found that applying shear stress by addition of a single Teflon bead to a rotating wall bioreactor improved microcin B17 production. By contrast, addition of various concentrations of ethanol to such bioreactors (or to shaken flasks) failed to increase microcin B17 production. Ethanol stress merely decreased production and, at higher concentrations, inhibited growth. Interestingly, cells growing in the bioreactor were much more resistant to the growth-inhibitory and production-inhibitory effects of ethanol than cells growing in shaken flasks.

  1. Large-scale production of lentiviral vector in a closed system hollow fiber bioreactor

    PubMed Central

    Sheu, Jonathan; Beltzer, Jim; Fury, Brian; Wilczek, Katarzyna; Tobin, Steve; Falconer, Danny; Nolta, Jan; Bauer, Gerhard

    2015-01-01

    Lentiviral vectors are widely used in the field of gene therapy as an effective method for permanent gene delivery. While current methods of producing small scale vector batches for research purposes depend largely on culture flasks, the emergence and popularity of lentiviral vectors in translational, preclinical and clinical research has demanded their production on a much larger scale, a task that can be difficult to manage with the numbers of producer cell culture flasks required for large volumes of vector. To generate a large scale, partially closed system method for the manufacturing of clinical grade lentiviral vector suitable for the generation of induced pluripotent stem cells (iPSCs), we developed a method employing a hollow fiber bioreactor traditionally used for cell expansion. We have demonstrated the growth, transfection, and vector-producing capability of 293T producer cells in this system. Vector particle RNA titers after subsequent vector concentration yielded values comparable to lentiviral iPSC induction vector batches produced using traditional culture methods in 225 cm2 flasks (T225s) and in 10-layer cell factories (CF10s), while yielding a volume nearly 145 times larger than the yield from a T225 flask and nearly three times larger than the yield from a CF10. Employing a closed system hollow fiber bioreactor for vector production offers the possibility of manufacturing large quantities of gene therapy vector while minimizing reagent usage, equipment footprint, and open system manipulation. PMID:26151065

  2. Influence of intermittent pressure, fluid flow, and mixing on the regenerative properties of articular chondrocytes.

    PubMed

    Carver, S E; Heath, C A

    1999-11-05

    Equine articular chondrocytes, embedded within a polyglycolic acid nonwoven mesh, were cultured with various combinations of intermittent pressure, fluid flow, and mixing to examine the effects of different physical stimuli on neochondrogenesis from young cells. The cell/polymer constructs were cultured first in 125 ml spinner flasks for 1, 2, or 4 weeks and then in a perfusion system with intermittent pressure for a total of up to 6 weeks. Additional constructs were either cultured for all 6 weeks in the spinner flasks or for 1 week in spinners followed by 5 weeks in the perfusion system without intermittent pressure. Tissue constructs cultivated for 2 or 4 weeks in spinner flasks followed by perfusion with intermittent pressure had significantly higher concentrations of both sulfated glycosaminoglycan and collagen than constructs cultured entirely in spinners or almost entirely in the pressure/perfusion system. Initial cultivation in the spinner flasks, with turbulent mixing, enhanced both cell attachment and early development of the extracellular matrix. Subsequent culture with perfusion and intermittent pressure appeared to accelerate matrix formation. While the correlation was much stronger in the pressurized constructs, the compressive modulus was directly proportional to the concentration of sulfated glycosaminoglycan in all physically stressed constructs. Constructs that were not stressed beyond the 1-week seeding period lost mechanical integrity upon harvest, suggesting that physical stimulation, particularly with intermittent pressure, of immature tissue constructs during their development may contribute to their ultimate biomechanical functionality. Copyright 1999 John Wiley & Sons, Inc.

  3. Using Isotope Ratio Infrared Spectrometer to determine δ13C of CaCO3 carbonate and DIC samples and δ18O of water

    NASA Astrophysics Data System (ADS)

    Mandic, M.; Stöbener, N.; Mandic, L.; Smajgl, D.; Jost, H. J. H.

    2016-12-01

    Precise and accurate determination of isotopic composition of carbon (13C) and oxygen (18O) from carbonate or DIC sample with proper referencing and data evaluation algorithm presents a challenge for scientists. Mass spectrometry was the only widely used technique for this kind of analysis, but recent advances make laser based isotope ratio infrared spectroscopy (IRIS) a viable alternative. To analyze discrete samples, the Universal Reference Interface (URI) Connect was developed. CO2 free syntethic air is used to flush out the contents of a sample container into a variable volume. If necessary, the sample is further diluted before entering the analysis chamber. Reference gas measurements are automatically performed at the same concentration as sample measurements to compensate for instrument drifts and non linearity. The URI Connect can handle about 100 samples per day from an autosampler, or samples can be injected one at a time through a septum on the front of the instrument. Gas samples collected in flasks, bags, syringes, or vials can be analyzed. The system only needs the equivalent of about 80µg - or 40µL - of pure CO2 gas to complete an analysis. Due to it's small weight and robustness, sample analysis can be performed in the field, e.g. aboard a research vessel. To demonstrate the performance, a test experiment with 1% CO2 in 12 ml vials was performed. We achieved an internal precision of better than 0.07‰ and 0.1‰ for δ13C and δ18O, respectively. Analyses with sample amounts as low as 200 μg of carbonate can also be performed reliably with IRIS. We present measurements of three international reference materials, and one of them treated as an unknown. Five samples each of approximately 1mg each were acidified using a few droplets of 43% H3PO4 and left for equilibration overnight at 25°C. The standard deviation was less than 0.1‰ δ13C and the accuracy <0.01‰ As another example of head space analysis in 12 ml vials, we determined δ18O of aliquots of 500 µl of water using equilibration with 1% CO2 in the volume above the water. The agreement with traditional IRMS methods was <0.06‰ was found.

  4. PubMed Central

    Miezan, T.; Doua, F.; Cattand, P.; de Raadt, P.

    1991-01-01

    The Testryp CATT was performed on dried blood samples on filter-paper and on diluted blood using a microtechnique. This method was applied to both sample collection techniques and was evaluated in parallel with the classical Testryp CATT on whole blood, as described in the instructions provided with the reagents by the manufacturer. A total of 2087 people were tested; 453 samples were tested in the laboratory and 1634 during a field survey in 5 villages of a trypanosomiasis focus in Daloa, Côte d'Ivoire. This study has demonstrated that the Testryp CATT micromethod on either type of sample collection gives results comparable to the Testryp CATT on whole blood. The collection of dried blood samples on filter-paper can be performed by non-specialized staff in trypanosomiasis control programmes of the national health services. In addition, a flask of CATT reagent will allow testing of 6 times more people by the micromethod than by the classical whole-blood method. The micromethod is suitable in the implementation of programmes for the serological surveillance of populations at risk. PMID:1959162

  5. A portable molecular-sieve-based CO{sub 2} sampling system for radiocarbon measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Palonen, V., E-mail: vesa.palonen@helsinki.fi

    We have developed a field-capable sampling system for the collection of CO{sub 2} samples for radiocarbon-concentration measurements. Most target systems in environmental research are limited in volume and CO{sub 2} concentration, making conventional flask sampling hard or impossible for radiocarbon studies. The present system captures the CO{sub 2} selectively to cartridges containing 13X molecular sieve material. The sampling does not introduce significant under-pressures or significant losses of moisture to the target system, making it suitable for most environmental targets. The system also incorporates a significantly larger sieve container for the removal of CO{sub 2} from chambers prior to the CO{submore » 2} build-up phase and sampling. In addition, both the CO{sub 2} and H{sub 2}O content of the sample gas are measured continuously. This enables in situ estimation of the amount of collected CO{sub 2} and the determination of CO{sub 2} flux to a chamber. The portable sampling system is described in detail and tests for the reliability of the method are presented.« less

  6. English Translation of Seven Papers on Thermophysical Properties

    DTIC Science & Technology

    1980-09-01

    capillary constant (eq. 18) *- a = surface tension (eq. 18) g = acceleration of gravity (eq. 18) v = atomic volume at the melting point - . .. M-16...Accuracyoft/"m Ex*Ceperiment C 1941 r1143 oil 181-195 0.4610.01 Specific gravity flask 1946 [20 - t, Ar (up to 332-160 0.517 1.01 Specific gravity ...i 65 arm) flask, 0.52 1ś No1 P, 1 Kb 16 319T 400-1125 0.503 1.021 Specific gravity 1970 163) was - 242.-917 0.304 0.95 Hydrostatic sun-pension. -. 3

  7. Investigations on the Use of Multi-Species Flask Measurements for Sector-Specific Fossil Fuel CO2 Attribution to Aid Policymakers

    NASA Astrophysics Data System (ADS)

    Nathan, B.; Lauvaux, T.; Turnbull, J. C.; Sweeney, C.; Karion, A.; Richardson, S.; Miles, N.; Gurney, K. R.; Patarasuk, R.

    2016-12-01

    Part of the Indianapolis Flux (INFLUX) Experiment has, since 2010, involved recording atmospheric trace gas measurements using NOAA flask packages. The goal of these measurements is to better inform policymakers about the behaviors of greenhouse gas emissions in the Indianapolis urban environment. Radiocarbon dioxide (14CO2) measurements recorded from the flasks allow for delineation of the fossil-fuel carbon dioxide (CO2ff) signal from the total carbon dioxide (CO2) measurement. To give policymakers even more detailed information, we investigate whether the co-measured trace gases could be used as tracers for economic source sectors of CO2ff as predefined by the bottom-up data product Hestia. This is extensively tested using an Observation System Simulation Experiment (OSSE) combining both a top-down approach for all species—influence functions from the tower flask measurements—, and attempting to assign sources via spatial overlaps with the available bottom-up inventory CO2ff source sector definitions. A self-organizing map is implemented for the mathematical attribution of signals to sources, because it can compensate for nonlinear signals (i.e. tracer emissions that do not scale linearly with CO2ff emissions). It is determined that proper attribution is at least not feasible with such a complete lack of bottom-up spatial information about all non-CO2ff potential tracers. This unfeasibility is shown not to be resolved by a test of expanding the dataset with many more theoretical measurements than are realistically available. Here we alter the approach to include the missing prior information: bottom-up estimates of the emission fluxes for a suite of species. We develop these bottom-up emission fluxes from existing whole-city emission fluxes, species-specific source sector partitioning, and the spatial patterns from Hestia CO2ff source sectors. We validate the general approach using the whole-city species: CO2ff ratios derived from all tower flask measurements. Finally, using these tools, multi-species, sector-specific inversions are investigated in the Bayesian framework.

  8. Energy yields in the prebiotic synthesis of hydrogen cyanide and formaldehyde

    NASA Technical Reports Server (NTRS)

    Stribling, R.; Miller, S. L.

    1986-01-01

    Prebiotic experiments are usually reported in terms of carbon yields, i.e., the yield of product based on the total carbon in the system. These experiments usually involve a large input of energy and are designed to maximize the yields of product. However, large inputs of energy result in multiple activation of the reactants and products. A more realistic prebiotic experiment is to remove the products of the activation step so they are not exposed a second time to the energy source. This is equivalent to transporting the products synthesized in the primitive atmosphere to the ocean, and thereby protecting them from destruction by atmospheric energy sources. Experiments of this type, using lower inputs of energy, give energy yields (moles of products/joule) which can be used to estimate the relative importance of the different energy sources on the primitive earth. Simulated prebiotic atmospheres containing either CH4, CO or CO2 with N2, H2O and variable amounts of H2 were subjected to a high frequency Tesla coil. Samples of the aqueous phase were taken at various time intervals from 1 hr to 7 days, and the energy yields were obtained by extrapolation to zero time. The samples were analyzed for HCN with the cyanide electrode and for H2CO by chromotropic acid. The spark energy was estimated by calorimetry. The temperature rise in an insulated discharge flask was compared with the temperature rise from a resistance heater in the same flask. These results will be compared with calculated production rates of HCN and H2CO from lightning and a number of photochemical processes on the primitive Earth.

  9. Postural control under clinorotation in upside-down catfish, Synodontis nigriventris.

    PubMed

    Ohnishi, K; Takahashi, A; Koyama, M; Ohnishi, T

    1996-12-01

    The upside-down catfish Synodontis nigriventris has a unique habit of swimming and resting upside-down in free water. This behavior leads to the assumption that the catfish has a specific gravity information processing system. We examined the postural control behaviors in the catfish under clinorotation which is usually used for producing pseudo-microgravity. Synodontis nigriventris kept its body posture at a stable area of the rotated flask in which the catfish was kept, when it was clinorotated at the rate of 60 rpm. In contrast to Synodontis nigriventris, a related species, Corydoras paleatus, did not show such steady postural control. When the flask was rotated at a lower rate of 30 rpm or a higher rate of 100 rpm, Synodontis nigriventris as well as Corydoras paleatus showed a considerable disturbed control of body posture. In this condition, they were frequently rotated with the flask. These findings suggest that Synodontis nigriventris has a high ability to keep upside-down posture and the gravity sensation in this catfish is likely to contribute to its different postural control from that of many other fishes.

  10. Flow characterization of a spinner flask for induced pluripotent stem cell culture application.

    PubMed

    Ismadi, Mohd-Zulhilmi; Gupta, Priyanka; Fouras, Andreas; Verma, Paul; Jadhav, Sameer; Bellare, Jayesh; Hourigan, Kerry

    2014-01-01

    We present detailed quantitative measurement analyses for flow in a spinner flask with spinning rates between 20 to 45 RPM, utilizing the optical velocimetry measurement technique of Particle Image Velocimetry (PIV). A partial section of the impeller was immersed in the working fluid to reduce the shear forces induced on the cells cultured on microcarriers. Higher rotational speeds improved the mixing effect in the medium at the expense of a higher shear environment. It was found that the mouse induced pluripotent stem (iPS) cells achieved the optimum number of cells over 7 days in 25 RPM suspension culture. This condition translates to 0.0984 Pa of maximum shear stress caused by the interaction of the fluid flow with the bottom surface. However, inverse cell growth was obtained at 28 RPM culture condition. Such a narrow margin demonstrated that mouse iPS cells cultured on microcarriers are very sensitive to mechanical forces. This study provides insight to biomechanical parameters, specifically the shear stress distribution, for a commercially available spinner flask over a wide range of Reynolds number.

  11. Observed Temporal Evolution of Global Mean Age of Stratospheric Air for the 2002 to 2010 Period

    NASA Astrophysics Data System (ADS)

    Stiller, G. P.; von Clarmann, T.; Haenel, F.; Funke, B.; Glatthor, N.; Grabowski, U.; Kellmann, S.; Kiefer, M.; Linden, A.; Lossow, S.; Lopez-Puertas, M.

    2011-12-01

    According to model calculations, the meridional circulation is expected to intensify as a result of climate change, and mean age of stratospheric air is expected to decrease. However, an observational data set presented recently (Engel et al., 2009) and consisting of 27 balloon samples of the age of air tracers carbon dioxide and sulfur hexafluoride covering the years 1975 to 2005 did not confirm the model predictions. As a contribution to the ongoing discussion, an extensive observational data set, consisting of more than 1 Million SF6 vertical profiles distributed globally is presented here. It has been derived from the MIPAS instrument covering the period 2002 to 2010 and has been converted into mean age of stratospheric air by referring to a combined data set of in-situ and flask global mean tropospheric SF6 measurements provided by NOAA/ESRL. During conversion into age of air, the non-linearity of tropospheric SF6 increase has been corrected for by convolution with the age spectrum within an iterative approach. Monthly zonal means of mean age of air, binned at 10 deg latitude and 1-2 km altitude, were analyzed with respect to their temporal variation by fitting a regression model consisting of a constant and a linear increase term, 2 proxies for the QBO variation, sinusoidal terms for the seasonal and semi-annual variation and overtones for the correction of the shapes to the observed data set. The impact of subsidence of mesospheric SF6-depleted air and in-mixing into non-polar latitudes on mid-latitudinal absolute age of air and the age-of-air linear increase was assessed and found to be small. The linear increase of mean age of stratospheric air was found to be positive and partly larger than the trend derived by Engel et al. (2009) for most of the Northern mid-latitudes, the middle stratosphere in the tropics, and parts of the Southern mid-latitudes, as well as for the Southern polar upper stratosphere. Multi-year decrease of age of air was found for the lowermost and the upper stratospheric tropics, for parts of Southern mid-latitudes, and for the Northern polar regions. Analysis of the amplitudes and phases of the seasonal variation shed light on the coupling of stratospheric regions to each other. In particular, the Northern mid-latitude stratosphere is well coupled to the tropics, while the Northern lowermost mid-latitudinal stratosphere is decoupled, confirming the separation of the shallow branch of the Brewer-Dobson circulation from the deep branch. We suggest an overall increased tropical upwelling, together with weakening of mixing barriers, especially in the Northern hemisphere, as a hypothetical model to explain the observed pattern of linear multi-year increase/decrease, and amplitudes and phase shifts of the seasonal variation. Reference: Engel, A., Möbius, T., Bönisch, H., Schmidt, U., Heinz, R., Levin, I., Atlas, E., Aoki, S., Nakazawa, T., Sugawara, S., Moore, F., Hurst, D., Elkins, J., Schauffler, S., Andrews, A., and Boering, K.: Age of stratospheric air unchanged within uncertainties over the past 30 years, Nature Geosci., 2, 28--31, doi:10.1038/ngeo388, 2009.

  12. Carbon Isotopes of Methane in the Atlantic Realm: Links Between Background Station Data and Emission Source Regions

    NASA Astrophysics Data System (ADS)

    Lowry, D.; Fisher, R. E.; Lanoisellé, M.; Nisbet, E. G.

    2011-12-01

    Large networks of cavity ring-down spectroscopy (CRDS) instruments to measure mixing ratios of greenhouse gases are currently being developed in wealthier populated regions. However, many major natural source regions are remote from wealthy nations, and there are often great logistical obstacles to setting up and maintaining continuous monitoring of these sources. Thus flux assessments in many regions of the world rely on a few unequally spaced 'background' stations, plus satellite interpolation. This limited network can be supplemented to great effect by methane isotope data to identify emissions from different sources and their region of emission. Ideally both carbon and hydrogen isotope signatures are needed for maximum separation of source groups. However the more complex analytical procedure and larger sample requirements for D/H measurement mean that resources are currently better utilized for high-precision carbon isotope (δ13C) measurement of methane. In particular, NOAA maintains an invaluable isotopic measurement network. Since 2008 the greenhouse gas group at Royal Holloway and partners have been measuring methane in and around the Atlantic region, currently measuring mixing ratios by CRDS at Barra (Scotland), Ascension, and E. Falklands. In addition, regular flask sampling for δ13C of CH4 is underway at these sites, plus Cape Point, South Africa, and Ny-Alesund, Spitzbergen, supplemented by collection at Sable Island, Canada, and sampling campaigns on-board the British Antarctic Survey ship, RRS James Clark Ross, between 50°S and 80°N. Methane mixing ratio and δ13C, when combined with back trajectory analysis, help to identify sources over which the air masses have passed. While the South Atlantic shows little N-S variation in δ13C (predominantly -47.2 to -46.8%) it is punctuated by emission plumes from sources in South America and Africa, and although infrequently sampled, they can in some instances be compared with the isotopic characteristics from source studies and monthly emission maps from satellite products. North Atlantic sites have a seasonal cycle (up to 0.7 to 0.8%) that increases polewards, reaching -48% in Arctic summer. Emissions contributing to this seasonal cycle and inter-annual anomalies in the cycle are wetlands (-70 to -55%, but generally more 13C-depleted with increasing latitude) and biomass burning (-30 to -25%). Added to these, and mostly with isotopic signatures between those of the two main natural sources, are anthropogenic fossil fuel (gas, coal), landfill, ruminant and vehicle emissions. The δ13C of the source mix that dominated the North Atlantic from 8 to 53°N in late September 2010 was -56.5%. This is lower than expected if anthropogenic emissions were dominant (eg. London -52 to -49%), but corresponds to the period when maximum influence of high latitude wetland (around -68%) is expected. Methane in air leaving the Eastern seaboard of Canada (Sable Island) allows regional contributions to the Atlantic mix to be assessed. These samples indicate a δ13C source mix of -52 ±2% for air leaving the NE USA and -60 ±2% for air leaving Southern Canada during summer 2010. Further north a wetland emission signal (-70 to -66%) has predominated during recent summers.

  13. Surface Forcing from CH4 at the North Slope of Alaska and Southern Great Plains Sites

    NASA Astrophysics Data System (ADS)

    Collins, W.; Feldman, D.; Turner, D. D.

    2014-12-01

    Recent increases in atmospheric CH4 have been spatially heterogeneous as indicated by in situ flask measurements and space-borne remote-sensing retrievals from the AIRS instrument, potentially leading to increased radiative forcing. We present detailed, specialized measurements at the DOE ARM North Slope of Alaska (NSA) and Southern Great Plains (SGP) sites to derive the time-series of both CH4 atmospheric concentrations and associated radiative implications at highly-contrasting natural and anthropogenic sources. Using a combination of spectroscopic measurements, in situ observations, and ancillary data for the atmospheric thermodynamic state from radiosondes and cloud-clearing from active sounders, we can separate out the contribution of CH4 to clear-sky downwelling radiance spectra and its infrared surface forcing. The time-series indicates year-to-year variation in shoulder season increases of CH4 concentration and forcing at NSA and large signals from anthropogenic activity at SGP.

  14. A strategy for the highly efficient production of docosahexaenoic acid by Aurantiochytrium limacinum SR21 using glucose and glycerol as the mixed carbon sources.

    PubMed

    Li, Jing; Liu, Ruijie; Chang, Guifang; Li, Xiangyu; Chang, Ming; Liu, Yuanfa; Jin, Qingzhe; Wang, Xingguo

    2015-02-01

    Glucose and glycerol are useful carbon sources for the cultivation of Aurantiochytrium limacinum SR21. Glucose facilitates rapid growth and lipid synthesis, and glycerol promotes the accumulation of docosahexaenoic acid (DHA) in A. limacinum SR21. To improve the DHA productivity of A. limacinum SR21, shake flask and fed-batch cultures were performed using glucose and glycerol as mixed carbon sources (MCSs). Along with optimization of the MCSs, the best DHA yield and productivity (32.36 g/L and 337.1 mg/L/h) were obtained via fed-batch fermentation with maintenance of a constant air supply. The DHA productivity was 15.24% higher than that obtained using glucose as single carbon source (SCS). This study presents a highly efficient and economic strategy for the production of DHA by A. limacinum SR21. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Microbial Beneficiation of Salem Iron Ore Using Penicillium purpurogenum

    NASA Astrophysics Data System (ADS)

    Mishra, M.; Pradhan, M.; Sukla, L. B.; Mishra, B. K.

    2011-02-01

    High alumina and silica content in the iron ore affects coke rate, reducibility, and productivity in a blast furnace. Iron ore is being beneficiated all around the world to meet the quality requirement of iron and steel industries. Choosing a beneficiation treatment depends on the nature of the gangue present and its association with the ore structure. The advanced physicochemical methods used for the beneficiation of iron ore are generally unfriendly to the environment. Biobeneficiation is considered to be ecofriendly, promising, and revolutionary solutions to these problems. A characterization study of Salem iron ore indicates that the major iron-bearing minerals are hematite, magnetite, and goethite. Samples on average contains (pct) Fe2O3-84.40, Fe (total)-59.02, Al2O3-7.18, and SiO2-7.53. Penicillium purpurogenum (MTCC 7356) was used for the experiment . It removed 35.22 pct alumina and 39.41 pct silica in 30 days in a shake flask at 10 pct pulp density, 308 K (35 °C), and 150 rpm. In a bioreactor experiment at 2 kg scale using the same organism, it removed 23.33 pct alumina and 30.54 pct silica in 30 days at 300 rpm agitation and 2 to 3 l/min aeration. Alumina and silica dissolution follow the shrinking core model for both shake flask and bioreactor experiments.

  16. Formation of harmful compounds in biotransformation of lilial by microorganisms isolated from human skin.

    PubMed

    Esmaeili, Akbar; Afshari, Shima; Esmaeili, Davood

    2015-01-01

    The biotransformation of lilial results in an acid that is used in the dairy industry, in perfumery, as an intermediate in the manufacture of pharmaceuticals and cosmetics, and as a food additive for enhancing taste. This study investigates the biotransformation of lilial by Staphylococcus aureus and Staphylococcus epidermidis, two bacterial species isolated from human skin. Both species of Staphylococcus were isolated in samples taken from the skin of individuals living in a rural area of Iran. The pH of the culture medium was optimized, and after culturing the microorganisms, the bacteria were added to a flask containing a nutrient broth and incubated for several hours. The flasks of bacteria were combined with lilial, and various biochemical tests and diagnostics were performed, including Fourier transform infrared spectroscopy (FT-IR), ultraviolet-visible spectrophotometry (UV-Vis), and gas chromatography-mass spectroscopy (GC-MS). The S. aureus produced isobutyric acid (2-methylpropanoic acid) after 72 h (71% of the total products yielded during biotransformation), whereas the S. epidermidis produced terpenoid alcoholic media after 24 h (90% of total products obtained). The results obtained indicate that biotransformation of lilial by S. aureus is more desirable than by S. epidermidis due to the highly efficient production of a single product. Bourgeonal and liliol were two toxic compounds produced during biotransformation, which indicates that the use of lilial in cosmetics can be harmful to the skin.

  17. Plant Uptake of Atmospheric Carbonyl Sulfide in Coast Redwood Forests

    NASA Astrophysics Data System (ADS)

    Campbell, J. E.; Whelan, M. E.; Berry, J. A.; Hilton, T. W.; Zumkehr, A.; Stinecipher, J.; Lu, Y.; Kornfeld, A.; Seibt, U.; Dawson, T. E.; Montzka, S. A.; Baker, I. T.; Kulkarni, S.; Wang, Y.; Herndon, S. C.; Zahniser, M. S.; Commane, R.; Loik, M. E.

    2017-12-01

    The future resilience of coast redwoods (Sequoia sempervirens) is now of critical concern due to the detection of a 33% decline in California coastal fog over the 20th century. However, ecosystem-scale measurements of photosynthesis and stomatal conductance are challenging in coast redwood forests, making it difficult to anticipate the impacts of future changes in fog. To address this methodological problem, we explore coastal variations in atmospheric carbonyl sulfide (COS or OCS), which could potentially be used as a tracer of these ecosystem processes. We conducted atmospheric flask campaigns in coast redwood sites, sampling at surface heights and in the canopy ( 70 m), at the University of California Landels-Hill Big Creek Reserve and Big Basin State Park. We simulated COS atmosphere-biosphere exchange with a high-resolution 3-D model to interpret these data. Flask measurements indicated a persistent daytime drawdown between the coast and the downwind forest (45 ± 6 ppt COS) that is consistent with the expected relationship between COS plant uptake, stomatal conductance, and gross primary production. Other sources and sinks of COS that could introduce noise to the COS tracer technique (soils, anthropogenic activity, nocturnal plant uptake, and surface hydrolysis on leaves) are likely to be small relative to daytime COS plant uptake. These results suggest that COS measurements may be useful for making ecosystem-scale estimates of carbon, water, and energy exchange in coast redwood forests.

  18. Molecular Engineering of Liquid Crystalline Polymers by Living Polymerization. 10. Influence of Molecular Weight on the Phase Transitions of Poly(Omega-((4-Cyano-4’-Biphenyl)oxy)alkyl Vinyl Ethers)s with Nonyl and Decanyl Alkyl Groups

    DTIC Science & Technology

    1990-10-16

    washed with concentrated sulfuric acid , then with water, dried over anhydrous magnesium sulfate, refluxed over calcium hydride and freshly distilled...oxide, filtered, and fractionally distilled under reduced pressure. Trifluoromethane sulfonic acid (triflic acid , 98%, Aldrich) w s distilled under...flask. Then the flask was filled with argon, cooled to 0°C and the methylene chloride, dimethyl sulfide and triflic acid were added via a syringe. The

  19. Formation, Structure and Properties of Boron Nitride Fibers from Polymer Precursors

    DTIC Science & Technology

    1992-02-25

    conversion, have been demonstrated in this study. Poly(ethylene oxide) (PEO), poly(N-vinyl-2-pyrrolidinone) ( PVP ), and poly(methyl methacrylate) (PMMA) were...vinylpyrrolidinone ( PVP , Mw = 360,000). A 100 ml reaction flask with teflon boiling chips and a 100 ml receiving flask were used on a high boiling distilling...CH 3 OBO) 3 : B(OH)3 Predicted 2 Experiment Experiment, 1 wt% PVP 2:1 47.8 mole% CH 3 OH 39.6 mole% CH 3OH 35.2 mole% CH3 OH 3:1 47.8 - 35.5 4:1 47.8

  20. DESIGN OF A SIMPLE SLOW COOLING DEVICE FOR CRYOPRESERVATION OF SMALL BIOLOGICAL SAMPLES.

    PubMed

    de Paz, Leonardo Juan; Robert, Maria Celeste; Graf, Daniel Adolfo; Guibert, Edgardo Elvio; Rodriguez, Joaquin Valentin

    2015-01-01

    Slow cooling is a cryopreservation methodology where samples are cooled to its storage temperature at controlled cooling rates. Design, construction and evaluation of a simple and low cost device for slow cooling of small biological samples. The device was constructed based on Pye's freezer idea. A Dewar flask filled with liquid nitrogen was used as heat sink and a methanol bath containing the sample was cooled at constant rates using copper bars as heat conductor. Sample temperature may be lowered at controlled cooling rate (ranging from 0.4°C/min to 6.0°C/min) down to ~-60°C, where it could be conserved at lower temperatures. An example involving the cryopreservation of Neuro-2A cell line showed a marked influence of cooling rate over post preservation cell viability with optimal values between 2.6 and 4.6°C/min. The cooling device proved to be a valuable alternative to more expensive systems allowing the assessment of different cooling rates to evaluate the optimal condition for cryopreservation of such samples.

  1. Observations of living non-spinose planktic foraminifers Neogloboquadrina dutertrei and N. pachyderma from specimens grown in culture

    NASA Astrophysics Data System (ADS)

    Fehrenbacher, J. S.; Spero, H. J.; Russell, A. D.

    2011-12-01

    Electron microprobe image mapping of the Mg/Ca ratio of the non-spinose foraminifera Neogloboquadrina dutertrei (N. dutertrei) reveal high inter (between shell) and intra (within shell) variability in Holocene age samples obtained from the Ceara Rise. EMPA images reveal some tests have relatively homogeneously distributed Mg/Ca ratios while other tests have bands of thin (2-3 μm) high Mg/Ca calcite intercalated between generally thicker (>2 μm) Mg/Ca layers. To gain insight into test development and the biological controls on the Mg/Ca ratio of N. dutertrei and another non-spinose species, N. pachyderma, living specimens were obtained from plankton tow material (~60-150 m depth) from the San Pedro basin ~2km off the coast of Santa Catalina Island, CA during the summer of 2011 and maintained in controlled environmental conditions at the Wrigley Marine Science Center. Specimens were observed under an inverted microscope and moved directly into polystyrene Falcon tissue culture flasks containing filtered seawater containing elevated [Ba] (200nM Ba; ~5x ambient) to label new shell calcite. Specimens were fed thawed one-day old frozen Artemia sp. nauplii every other day when possible (feeding was dependent upon the presence of active rhizopodia). In N. dutertrei , we observed small coccoid symbiotic algae, gametes and/or symbionts released during gametogenesis, and new chamber growth while in culture. N. dutertrei adhered to the bottom of the falcon flasks with the pseudopodia. Pseudopodia were often 2x as long as the maximum width of the test and extended in all directions. N. pachyderma were observed, similar to N. dutertrei, with pseudopodia also extended in all directions and adhered to the bottom of the falcon flask. The cytoplasm of both species was bright orange to reddish, possibly reflecting their food source. We plan to present preliminary geochemical data from laser-ablation - ICPMS profiles to document calcite addition across the test and to determine the relationship of Mg/Ca variability to test ontogeny.

  2. Baseline Measurements of Trace Gases at High Mountain and Sea-level Stations in Taiwan

    NASA Astrophysics Data System (ADS)

    Ou-Yang, C.; Wang, J.; Lin, N.; Lee, C.; Sheu, G.; Hsieh, H.; Liu, W.

    2012-12-01

    High mountains in Taiwan may serve as ideal locations to monitor seasonal alternation of air masses from Asian continental outflow from mainland China, biomass burning from Southeast Asia, and oceanic influences from the Pacific. The operation of Lulin Atmospheric Background Station (LABS, 23.51°N, 120.92°E, 2862 m a.s.l.) started in April 2006, aiming at studying the regional baseline conditions and its coupling with local air quality. Based on six-year's measurements, the springtime maximum of CO and O3 is likely caused by the long-range transport of air masses from Southeast Asia with biomass burning signature. In contrast, the Pacific oceanic air masses cause the summertime minimum. Diurnal variations of CO and O3 at LABS were found to be different from those at the surface. CO show maximum levels in late afternoon, and minima at night. O3 however shows a nearly opposite cycle to CO with minima at noon. Intriguingly, this O3 diurnal pattern repeated for five years, but changed since May 2011 for reasons that remain to be unraveled. Ozone depleting substance such as CFCs and Halons, and GHGs such as CO2 and CH4 were observed continuously at LABS since December 2007 and March 2011, respectively. Years after the implementation of the Montreal Protocols for the A5 countries, the ODS are expected to decline over time. Based on the measurements of seven halocarbons at LABS, most of the species are found to be either leveling off or decreasing during this period. For CO2 and CH4 measurements, a cavity ring-down spectroscopy was used and their seasonal variations were found to be similar to those at other sites in the East Asia. The results of flask samples analyzed by NOAA/ESRL/GMD were also discussed in this study. In addition to LABS, baseline observation was also conducted on a small island - Dongsha (20.70°N, 116.73°E), which is situated between Taiwan and the Philippines, serving as an ideal representative of the northern South China Sea. Both GHGs and O3 were measured during the spring of 2010. Our measurements and simulations suggested that strong northeasterly winds arising from the spring Asian monsoon may have transported polluted air masses from the northern continent to locations as south as Dongsha. Asian continental outflow is likely to be the cause for the seasonality of GHGs measured at Dongsha Island.

  3. Simple method for determination of selenium in biological materials by flameless atomic-absorption spectrometry using a carbon-tube atomizer.

    PubMed

    Ishizaki, M

    1978-03-01

    A method for determination of selenium in biological materials by flameless atomic-absorption spectrometry using a carbon-tube atomizer is described. The sample is burned by an oxygen-flask combustion procedure, the resulting solution is treated with a cation-exchange resin to eliminate interfering cations, the selenium is extracted with dithizone in carbon tetrachloride and the resulting selenium dithizonate is combined with nickel nitrate in the carbon tube to enhance the sensitivity for selenium and avoid volatilization losses. The method measures selenium concentrations as low as 0.01 mug/g with a relative standard deviation of 8%.

  4. Effect of a new tension system, used in acrylic resin flasking, on the dimensional stability of denture bases.

    PubMed

    Consani, Rafael Leonardo Xediek; Domitti, Saide Sarckis; Consani, Simonides

    2002-09-01

    The pressure of final closure may be released when the flask is removed from the mechanical or pneumatic press and placed in the spring clamp. This release in pressure may result in dimensional changes that distort the denture base. The purpose of this study was to investigate differences between the dimensional stability of standardized simulated denture bases processed by traditional moist heat-polymerization and those processed by use of a new tension system. A metal master die was fabricated to simulate an edentulous maxillary arch without irregularities in the alveolar ridge walls. A silicone mold of this metallic die was prepared, and 40 stone casts were formed from the mold with type III dental stone. The casts were randomly assigned to 4 test groups (A-D) of 10 specimens each. A uniform denture base pattern was made on each stone cast with a 1.5-mm thickness of base-plate wax, measured with a caliper. The patterns were invested for traditional hot water processing. A polymethyl methacrylate dough was prepared and packed for processing. The flasks in groups A and B were closed with the traditional pressure technique and placed in spring clamps after final closure. The flasks in groups C and D were pressed between the metallic plates of the new tension system after the final closure. The group A and C flasks were immediately immersed in the water processing unit at room temperature (25 degrees +/- 2 degrees C). The unit was programmed to raise the temperature to 74 degrees C over 1 hour, and then maintained the temperature at 74 degrees C for 8 hours. The group B and D flasks were bench stored at room temperature (25 degrees +/- 2 degrees C) for 6 hours and were then subjected to the same moist heat polymerization conditions as groups A and C. All processed dentures were bench cooled for 3 hours. After recovery from the flasks, the base-cast sets were transversally sectioned into 3 parts (corresponding to 3 zones): (1) distal of the canines, (2) mesial of the first molars, and (3) mesial of the posterior palate). These areas had been previously established and standardized by use of a pattern denture in the sawing device to determine the sections in each base-cast set. Base-cast gaps were measured at 5 predetermined points on each section with an optical micrometer that had a tolerance of 0.001 mm. Collected data were analyzed with analysis of variance and Tukey's test. Denture bases processed with the new tension system exhibited significantly better base adaptation than those processed with traditional acrylic resin packing. Immediately after polymerization (Groups A and C), mean dimensional change values were 0.213 +/- 0.055 mm for the traditional packing technique and 0.173 +/- 0.050 mm for new tension system. After delayed polymerization (Groups B and D), the values were 0.216 +/- 0.074 mm for the traditional packing technique and 0.164 +/- 0.032 mm for new tension system. With both techniques, dimensional changes in the posterior palatal zone were greater (conventional = 0.286 +/- 0.038 mm; new system = 0.214 +/- 0.024 mm) than those elsewhere on the base-cast set. Within the limitations of this study, the new tension packing system was associated with decreased dimensional changes in the simulated maxillary denture bases processed with heat-polymerization.

  5. Simulated conditions of microgravity suppress progesterone production by luteal cells of the pregnant rat

    NASA Technical Reports Server (NTRS)

    Bhat, G. K.; Yang, H.; Sridaran, R.

    2001-01-01

    The purpose of this study was to assess whether simulated conditions of microgravity induce changes in the production of progesterone by luteal cells of the pregnant rat ovary using an in vitro model system. The microgravity environment was simulated using either a high aspect ratio vessel (HARV) bioreactor with free fall or a clinostat without free fall of cells. A mixed population of luteal cells isolated from the corpora lutea of day 8 pregnant rats was attached to cytodex microcarrier beads (cytodex 3). These anchorage dependent cells were placed in equal numbers in the HARV or a spinner flask control vessel in culture conditions. It was found that HARV significantly reduced the daily production of progesterone from day 1 through day 8 compared to controls. Scanning electron microscopy showed that cells attached to the microcarrier beads throughout the duration of the experiment in both types of culture vessels. Cells cultured in chamber slide flasks and placed in a clinostat yielded similar results when compared to those in the HARV. Also, when they were stained by Oil Red-O for lipid droplets, the clinostat flasks showed a larger number of stained cells compared to control flasks at 48 h. Further, the relative amount of Oil Red-O staining per milligram of protein was found to be higher in the clinostat than in the control cells at 48 h. It is speculated that the increase in the level of lipid content in cells subjected to simulated conditions of microgravity may be due to a disruption in cholesterol transport and/or lesions in the steroidogenic pathway leading to a fall in the synthesis of progesterone. Additionally, the fall in progesterone in simulated conditions of microgravity could be due to apoptosis of luteal cells.

  6. Influence of Light Intensity on Growth and Pigment Production by Monascus ruber in Submerged Fermentation.

    PubMed

    Bühler, Rose Marie Meinicke; Müller, Bruna Luíse; Moritz, Denise Esteves; Vendruscolo, Francielo; de Oliveira, Debora; Ninow, Jorge Luiz

    2015-07-01

    To reduce environmental problems caused by glycerine accumulation and to make the production of biodiesel more profitable, crude glycerin without treatment was used as substrate for obtaining higher value-added bioproducts. Monascus ruber is a filamentous fungus that produces pigments, particularly red ones, which are used for coloring foods (rice wine and meat products). The interest in developing pigments from natural sources is increasing due to the restriction of using synthetic dyes. The effects of temperature, pH, microorganism morphology, aeration, nitrogen source, and substrates have been studied in the cultivation of M. ruber. In this work, it was observed that light intensity is also an important factor that should be considered for understanding the metabolism of the fungus. In M. ruber cultivation, inhibition of growth and pigment production was observed in Petri dishes and blaffed flasks exposed to direct illumination. Growth and pigment production were higher in Petri dishes and flasks exposed to red light and in the absence of light. Radial growth rate of M. ruber in plates in darkness was 1.50 mm day(-1) and in plates exposed to direct illumination was 0.59 mm day(-1). Maximum production of red pigments (8.32 UA) and biomass (8.82 g L(-1)) were obtained in baffled flasks covered with red film and 7.17 UA of red pigments, and 7.40 g L(-1) of biomass was obtained in flasks incubated in darkness. Under conditions of 1248 lux of luminance, the maximum pigment production was 4.48 UA, with production of 6.94 g L(-1) of biomass, indicating that the fungus has photoreceptors which influence the physiological responses.

  7. Three-dimensional dynamic fabrication of engineered cartilage based on chitosan/gelatin hybrid hydrogel scaffold in a spinner flask with a special designed steel frame.

    PubMed

    Song, Kedong; Li, Liying; Li, Wenfang; Zhu, Yanxia; Jiao, Zeren; Lim, Mayasari; Fang, Meiyun; Shi, Fangxin; Wang, Ling; Liu, Tianqing

    2015-10-01

    Cartilage transplantation using in vitro tissue engineered cartilage is considered a promising treatment for articular cartilage defects. In this study, we assessed the advantages of adipose derived stem cells (ADSCs) combined with chitosan/gelatin hybrid hydrogel scaffolds, which acted as a cartilage biomimetic scaffold, to fabricate a tissue engineered cartilage dynamically in vitro and compared this with traditional static culture. Physical properties of the hydrogel scaffolds were evaluated and ADSCs were inoculated into the hydrogel at a density of 1×10(7) cells/mL and cultured in a spinner flask with a special designed steel framework and feed with chondrogenic inductive media for two weeks. The results showed that the average pore size, porosity, swelling rate and elasticity modulus of hybrid scaffolds with good biocompatibility were 118.25±19.51 μm, 82.60±2.34%, 361.28±0.47% and 61.2±0.16 kPa, respectively. ADSCs grew well in chitosan/gelatin hybrid scaffold and successfully differentiated into chondrocytes, showing that the scaffolds were suitable for tissue engineering applications in cartilage regeneration. Induced cells cultivated in a dynamic spinner flask with a special designed steel frame expressed more proteoglycans and the cell distribution was much more uniform with the scaffold being filled mostly with extracellular matrix produced by cells. A spinner flask with framework promoted proliferation and chondrogenic differentiation of ADSCs within chitosan/gelatin hybrid scaffolds and accelerated dynamic fabrication of cell-hydrogel constructs, which could be a selective and good method to construct tissue engineered cartilage in vitro. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Evaluating maturation and genetic modification of human dendritic cells in a new polyolefin cell culture bag system.

    PubMed

    Macke, Lars; Garritsen, Henk S P; Meyring, Wilhelm; Hannig, Horst; Pägelow, Ute; Wörmann, Bernhard; Piechaczek, Christoph; Geffers, Robert; Rohde, Manfred; Lindenmaier, Werner; Dittmar, Kurt E J

    2010-04-01

    Dendritic cells (DCs) are applied worldwide in several clinical studies of immune therapy of malignancies, autoimmune diseases, and transplantations. Most legislative bodies are demanding high standards for cultivation and transduction of cells. Closed-cell cultivating systems like cell culture bags would simplify and greatly improve the ability to reach these cultivation standards. We investigated if a new polyolefin cell culture bag enables maturation and adenoviral modification of human DCs in a closed system and compare the results with standard polystyrene flasks. Mononuclear cells were isolated from HLA-A*0201-positive blood donors by leukapheresis. A commercially available separation system (CliniMACS, Miltenyi Biotec) was used to isolate monocytes by positive selection using CD14-specific immunomagnetic beads. The essentially homogenous starting cell population was cultivated in the presence of granulocyte-macrophage-colony-stimulating factor and interleukin-4 in a closed-bag system in parallel to the standard flask cultivation system. Genetic modification was performed on Day 4. After induction of maturation on Day 5, mature DCs could be harvested and cryopreserved on Day 7. During the cultivation period comparative quality control was performed using flow cytometry, gene expression profiling, and functional assays. Both flasks and bags generated mature genetically modified DCs in similar yields. Surface membrane markers, expression profiles, and functional testing results were comparable. The use of a closed-bag system facilitated clinical applicability of genetically modified DCs. The polyolefin bag-based culture system yields DCs qualitatively and quantitatively comparable to the standard flask preparation. All steps including cryopreservation can be performed in a closed system facilitating standardized, safe, and reproducible preparation of therapeutic cells.

  9. Process optimization involving critical evaluation of oxygen transfer, oxygen uptake and nitrogen limitation for enhanced biomass and lipid production by oleaginous yeast for biofuel application.

    PubMed

    Chopra, Jayita; Sen, Ramkrishna

    2018-04-20

    Lipid accumulation in oleaginous yeast is generally induced by nitrogen starvation, while oxygen saturation can influence biomass growth. Systematic shake flask studies that help in identifying the right nitrogen source and relate its uptake kinetics to lipid biosynthesis under varying oxygen saturation conditions are very essential for addressing the bioprocessing-related issues, which are envisaged to occur in the fermenter scale production. In the present study, lipid bioaccumulation by P. guilliermondii at varying C:N ratios and oxygen transfer conditions (assessed in terms of k L a) was investigated in shake flasks using a pre-optimized N-source and a two-stage inoculum formulated in a hybrid medium. A maximum lipid concentration of 10.8 ± 0.5 g L -1 was obtained in shake flask study at the optimal condition with an initial C:N and k L a of 60:1 and 0.6 min -1 , respectively, at a biomass specific growth rate of 0.11 h -1 . Translating these optimal shake flask conditions to a 3.7 L stirred tank reactor resulted in biomass and lipid concentrations of 16.74 ± 0.8 and 8 ± 0.4 g L -1 . The fatty acid methyl ester (FAME) profile of lipids obtained by gas chromatography was found to be suitable for biodiesel application. We strongly believe that the rationalistic approach-based design of experiments adopted in the study would help in achieving high cell density with improved lipid accumulation and also minimize the efforts towards process optimization during bioreactor level operations, consequently reducing the research and development-associated costs.

  10. Continued emissions of carbon tetrachloride from the United States nearly two decades after its phaseout for dispersive uses

    NASA Astrophysics Data System (ADS)

    Hu, Lei; Montzka, Stephen A.; Miller, Ben R.; Andrews, Arlyn E.; Miller, John B.; Lehman, Scott J.; Sweeney, Colm; Miller, Scot M.; Thoning, Kirk; Siso, Carolina; Atlas, Elliot L.; Blake, Donald R.; de Gouw, Joost; Gilman, Jessica B.; Dutton, Geoff; Elkins, James W.; Hall, Bradley; Chen, Huilin; Fischer, Marc L.; Mountain, Marikate E.; Nehrkorn, Thomas; Biraud, Sebastien C.; Moore, Fred L.; Tans, Pieter

    2016-03-01

    National-scale emissions of carbon tetrachloride (CCl4) are derived based on inverse modeling of atmospheric observations at multiple sites across the United States from the National Oceanic and Atmospheric Administration's flask air sampling network. We estimate an annual average US emission of 4.0 (2.0-6.5) Gg CCl4 y-1 during 2008-2012, which is almost two orders of magnitude larger than reported to the US Environmental Protection Agency (EPA) Toxics Release Inventory (TRI) (mean of 0.06 Gg y-1) but only 8% (3-22%) of global CCl4 emissions during these years. Emissive regions identified by the observations and consistently shown in all inversion results include the Gulf Coast states, the San Francisco Bay Area in California, and the Denver area in Colorado. Both the observation-derived emissions and the US EPA TRI identified Texas and Louisiana as the largest contributors, accounting for one- to two-thirds of the US national total CCl4 emission during 2008-2012. These results are qualitatively consistent with multiple aircraft and ship surveys conducted in earlier years, which suggested significant enhancements in atmospheric mole fractions measured near Houston and surrounding areas. Furthermore, the emission distribution derived for CCl4 throughout the United States is more consistent with the distribution of industrial activities included in the TRI than with the distribution of other potential CCl4 sources such as uncapped landfills or activities related to population density (e.g., use of chlorine-containing bleach).

  11. Stable Isotope Measurements of Carbon Dioxide, Methane, and Hydrogen Sulfide Gas Using Frequency Modulation Spectroscopy

    NASA Astrophysics Data System (ADS)

    Nowak-Lovato, K.

    2014-12-01

    Seepage from enhanced oil recovery, carbon storage, and natural gas sites can emit trace gases such as carbon dioxide, methane, and hydrogen sulfide. Trace gas emission at these locations demonstrate unique light stable isotope signatures that provide information to enable source identification of the material. Light stable isotope detection through surface monitoring, offers the ability to distinguish between trace gases emitted from sources such as, biological (fertilizers and wastes), mineral (coal or seams), or liquid organic systems (oil and gas reservoirs). To make light stable isotope measurements, we employ the ultra-sensitive technique, frequency modulation spectroscopy (FMS). FMS is an absorption technique with sensitivity enhancements approximately 100-1000x more than standard absorption spectroscopy with the advantage of providing stable isotope signature information. We have developed an integrated in situ (point source) system that measures carbon dioxide, methane and hydrogen sulfide with isotopic resolution and enhanced sensitivity. The in situ instrument involves the continuous collection of air and records the stable isotope ratio for the gas being detected. We have included in-line flask collection points to obtain gas samples for validation of isotopic concentrations using our in-house isotope ratio mass spectroscopy (IRMS). We present calibration curves for each species addressed above to demonstrate the sensitivity and accuracy of the system. We also show field deployment data demonstrating the capabilities of the system in making live dynamic measurements from an active source.

  12. First measurements of continuous δ18O-CO2 with a Fourier Transform InfraRed spectrometer in Heidelberg, Germany

    NASA Astrophysics Data System (ADS)

    Vardag, S. N.; Hammer, S.; Sabasch, M.; Griffith, D. W. T.; Levin, I.

    2014-07-01

    The continuous in-situ measurement of δ18O in atmospheric CO2 opens a new door to differentiating between CO2 source and sink components with high temporal resolution. Continuous 13C-CO2 measurement systems have been commercially available already for some time, but until now, only few instruments have been able to provide a continuous measurement of the oxygen isotope ratio in CO2. Besides precise 13C/12C observations, the Fourier Transform InfraRed (FTIR) spectrometer also measures the 18O/16O ratio of CO2, but the precision and accuracy of the measurements has not been evaluated yet. Here we present a first analysis of δ18O-CO2 (and δ13C-CO2) measurements with the FTIR in Heidelberg. We find that our spectrometer measures 18O in CO2 with a reproducibility of better than 0.3‰ at a temporal resolution of less than 10 min, as determined from surveillance gas measurements over a period of ten months. An Allan deviation test shows that the δ18O repeatability reaches 0.15‰ for half-hourly means. The compatibility of our spectroscopic measurements was determined by comparing FTIR measurements of calibration gases and ambient air to mass-spectrometric measurements of flask samples, filled with the cylinder gases or episodically collected over a diurnal cycle (event). We found that direct cylinder gas measurements agree to 0.01 ± 0.04‰ (mean and standard deviation) for δ13C-CO2 and 0.01 ± 0.11‰ for δ18O. Two weekly episodes of recent ambient air measurements, one in winter and one in summer, are discussed in view of the question, which potential insights and new challenges combined highly resolved δ18O-CO2 and δ13C-CO2 records may provide in terms of better understanding regional scale continental carbon exchange processes.

  13. U.S. emissions of HFC-134a derived for 2008-2012 from an extensive flask-air sampling network

    NASA Astrophysics Data System (ADS)

    Hu, Lei; Montzka, Stephen A.; Miller, John B.; Andrews, Aryln E.; Lehman, Scott J.; Miller, Benjamin R.; Thoning, Kirk; Sweeney, Colm; Chen, Huilin; Godwin, David S.; Masarie, Kenneth; Bruhwiler, Lori; Fischer, Marc L.; Biraud, Sebastien C.; Torn, Margaret S.; Mountain, Marikate; Nehrkorn, Thomas; Eluszkiewicz, Janusz; Miller, Scot; Draxler, Roland R.; Stein, Ariel F.; Hall, Bradley D.; Elkins, James W.; Tans, Pieter P.

    2015-01-01

    national and regional emissions of HFC-134a are derived for 2008-2012 based on atmospheric observations from ground and aircraft sites across the U.S. and a newly developed regional inverse model. Synthetic data experiments were first conducted to optimize the model assimilation design and to assess model-data mismatch errors and prior flux error covariances computed using a maximum likelihood estimation technique. The synthetic data experiments also tested the sensitivity of derived national and regional emissions to a range of assumed prior emissions, with the goal of designing a system that was minimally reliant on the prior. We then explored the influence of additional sources of error in inversions with actual observations, such as those associated with background mole fractions and transport uncertainties. Estimated emissions of HFC-134a range from 52 to 61 Gg yr-1 for the contiguous U.S. during 2008-2012 for inversions using air transport from Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model driven by the 12 km resolution meteorogical data from North American Mesoscale Forecast System (NAM12) and all tested combinations of prior emissions and background mole fractions. Estimated emissions for 2008-2010 were 20% lower when specifying alternative transport from Stochastic Time-Inverted Lagrangian Transport (STILT) model driven by the Weather Research and Forecasting (WRF) meteorology. Our estimates (for HYSPLIT-NAM12) are consistent with annual emissions reported by U.S. Environmental Protection Agency for the full study interval. The results suggest a 10-20% drop in U.S. national HFC-134a emission in 2009 coincident with a reduction in transportation-related fossil fuel CO2 emissions, perhaps related to the economic recession. All inversions show seasonal variation in national HFC-134a emissions in all years, with summer emissions greater than winter emissions by 20-50%.

  14. Influence of simulated microgravity on the longevity of insect-cell culture

    NASA Technical Reports Server (NTRS)

    Cowger, N. L.; O'Connor, K. C.; Bivins, J. E.

    1997-01-01

    Simulated microgravity within the NASA High Aspect Rotating-Wall Vessel (HARV) provides a quiescent environment to culture fragile insect cells. In this vessel, the duration of stationary and death phase for cultures of Spodoptera frugiperda cells was greatly extended over that achieved in shaker-flask controls. For both HARV and control cultures, S. frugiperda cells grew to concentrations in excess of 1 x 10(7) viable cells ml-1 with viabilities greater than 90%. In the HARV, stationary phase was maintained 9-15 days in contrast to 4-5 days in the shaker flask. Furthermore, the rate of cell death was reduced in the HARV by a factor of 20-90 relative to the control culture and was characterized with a death rate constant of 0.01-0.02 day-1. Beginning in the stationary phase and continuing in the death phase, there was a significant decrease in population size in the HARV versus an increase in the shaker flask. This phenomenon could represent cell adaptation to simulated microgravity and/or a change in the ratio of apoptotic to necrotic cells. Differences observed in this research between the HARV and its control were attributed to a reduction in hydrodynamic forces in the microgravity vessel.

  15. Highly Efficient Large-Scale Lentiviral Vector Concentration by Tandem Tangential Flow Filtration

    PubMed Central

    Cooper, Aaron R.; Patel, Sanjeet; Senadheera, Shantha; Plath, Kathrin; Kohn, Donald B.; Hollis, Roger P.

    2014-01-01

    Large-scale lentiviral vector (LV) concentration can be inefficient and time consuming, often involving multiple rounds of filtration and centrifugation. This report describes a simpler method using two tangential flow filtration (TFF) steps to concentrate liter-scale volumes of LV supernatant, achieving in excess of 2000-fold concentration in less than 3 hours with very high recovery (>97%). Large volumes of LV supernatant can be produced easily through the use of multi-layer flasks, each having 1720 cm2 surface area and producing ~560 mL of supernatant per flask. Combining the use of such flasks and TFF greatly simplifies large-scale production of LV. As a demonstration, the method is used to produce a very high titer LV (>1010 TU/mL) and transduce primary human CD34+ hematopoietic stem/progenitor cells at high final vector concentrations with no overt toxicity. A complex LV (STEMCCA) for induced pluripotent stem cell generation is also concentrated from low initial titer and used to transduce and reprogram primary human fibroblasts with no overt toxicity. Additionally, a generalized and simple multiplexed real- time PCR assay is described for lentiviral vector titer and copy number determination. PMID:21784103

  16. Spectral lights trigger biomass accumulation and production of antioxidant secondary metabolites in adventitious root cultures of Stevia rebaudiana (Bert.).

    PubMed

    Idrees, Muhammad; Sania, Bibi; Hafsa, Bibi; Kumari, Sana; Khan, Haji; Fazal, Hina; Ahmad, Ishfaq; Akbar, Fazal; Ahmad, Naveed; Ali, Sadeeq; Ahmad, Nisar

    2018-05-30

    Stevia rebaudiana (S. rebaudiana) is the most important therapeutic plant species and has been accepted as such worldwide. It has a tendency to accumulate steviol glycosides, which are 300 times sweeter than marketable sugar. Recently, diabetic patients commonly use this plant as a sugar substitute for sweet taste. In the present study, the effects of different spectral lights were investigated on biomass accumulation and production of secondary metabolites in adventitious root cultures of S. rebaudiana. For callus development, leaf explants were excised from seed-derived plantlets and inoculated on a Murashige and Skoog (MS) medium containing the combination of 2,4-dichlorophenoxy acetic acid (2, 4-D, 2.0mg/l) and 6-benzyladenine (BA, 2.0mg/l), while 0.5mg/l naphthalene acetic acid (NAA) was used for adventitious root culture. Adventitious root cultures were exposed to different spectral lights (blue, green, violet, red and yellow) for a 30-day period. White light was used as control. The growth kinetics was studied for 30days with 3-day intervals. In this study, the violet light showed the maximum accumulation of fresh biomass (2.495g/flask) as compared to control (1.63g/flask), while red light showed growth inhibition (1.025g/flask) as compared to control. The blue light enhanced the highest accumulation of phenolic content (TPC; 6.56mg GAE/g DW), total phenolic production (TPP; 101mg/flask) as compared to control (5.44mg GAE/g DW; 82.2mg GAE/g DW), and exhibited a strong correlation with dry biomass. Blue light also improved the accumulation of total flavonoid content (TFC; 4.33mg RE/g DW) and total flavonoid production (TFP; 65mg/flask) as compared to control. The violet light showed the highest DPPH inhibition (79.72%), while the lowest antioxidant activity was observed for control roots (73.81%). Hence, we concluded that the application of spectral lights is an auspicious strategy for the enhancement of the required antioxidant secondary metabolites in adventitious root cultures of S. rebaudiana and of other medicinal plants. Copyright © 2018 Académie des sciences. Published by Elsevier Masson SAS. All rights reserved.

  17. Orbital experiment ``Gravisensor'': phototropic reactions of the moss Physcomitrella patens to different types of LED lighting.

    NASA Astrophysics Data System (ADS)

    Nikitin, Vladimir; Berkovich, Yuliy A.; Skripnikov, Alexander; Zyablova, Natalya; Mukhoyan, Makar; Emelianov, Grigory

    The experiment was conducted on Russian Biological Satelite Bion-M #1 19.04-19.05 2013. Five transparent plastic cultural flasks were placed in five light isolated sections of Biocont-B2 cylindrical container with inner diameter of 120 mm and height of 230 mm. In four sections the flasks could be illuminated by top or side LED with wavelength of 458 nm, 630 nm, 730 nm, and white (color temperature 5000° K, peaks 453, 559 nm). Photon flux in each variant was 15 umol/(m2c). In the fifth section the flask with the shoots was in conditions of constant dark. Each section was equipped with its own video camera module. Cameras, video recorder and lighting were managed by micro controller. 12 days before launch, 5 tips of the moss shoots were explanted at each of the five flasks on the agar medium with nutrient components and were cultivated under white fluorescent lamps at 12 hour photo period till the launch. After entering the orbit and during next 14 days of flight top LEDs were turned on above the flasks. Then for the following 14 days of flight the side LEDs of similar wavelength were turned on. The moss gametophores were cultivated at 12-h photoperiod. During the experiment on an hourly basis a video recording of the moss was performed. Similar equipment was used for ground control. After the experiment video files were used to produce separate time-lapse films for each flask using AviSynth program. In flight the shoots demonstrated the maximum growth speed with far red lighting and slower speed with white lighting. With blue and red lighting after switching to side light stimuli the growth of shoots almost stopped. In the dark the shoots continued to grow until the 13 day after launch of the satellite, then their growth stopped. In ground control the relation of growth rate with various LEDs remained basically the same, with the exception of side blue lighting, where the shoots demonstrated considerable vertical growth. In flight the angle of inclination towards the light source was maximal (about 90º) with white lighting, and somewhat smaller with 730 nm. Under red and blue light the angle of phototropic inclination was difficult to measure due to poor growth of the shoots.In ground control the growth rate under blue light was several times higher, than in flight and final degree of inclination of the shoot tip came to about 10º. In ground control under side red lighting the growth was weak, while demonstrating a pronounced phototropic bend of 90º. In ground control in the dark a vertical growth of one shoot was observed with the rate somewhat larger, than in flight variant. Data on the dynamics of inclination of experimental and control plants are presented. The acquired data will be used to analyse the mechanisms of phototropic growth changes of moss shoots.

  18. In-house PCR with DNA extracted directly from positive slides to confirm or exclude the diagnosis of tuberculosis: focus on biosafety.

    PubMed

    de Almeida, Isabela Neves; Aleixo, Agdemir Valéria; Carvalho, Wânia da Silva; de Miranda, Silvana Spindola

    2015-01-01

    The possibility to obtain DNA from smears is a valuable alternative to remedy the lack of samples when they are totally used for bacilloscopy; this technique solves the biosafety problem related to a possible accident with the transportation of flasks containing potentially transmissible clinical samples. Hence, the purpose of this study was to utilize the insertion sequence IS6110 for amplification of DNA from a smear-positive sample for tuberculosis (TB) diagnosis. Among the 52 positive bacilloscopies, sensitivity, specificity, positive predictive value and negative predictive value were 52.3%, 100%, 100% and 89.7%, respectively whereas accuracy was 90.7%. The IS6110-based PCR for TB diagnosis developed in DNA extracted from a positive smear is a fast, simple, specific, and safe method. Copyright © 2014 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Screening soy hydrolysates for the production of a recombinant therapeutic protein in commercial cell line by combined approach of near-infrared spectroscopy and chemometrics.

    PubMed

    Li, Guiyang; Wen, Zai-Qing

    2013-03-01

    Soy hydrolysates are widely used as the major nutrient sources for cell culture processes for industrial manufacturing of therapeutic recombinant proteins. The primary goal of this study was to develop a spectroscopy based chemometric method, a partial least squares (PLS), to screen soy hydrolysates for better yield of protein production (titers) in cell culture medium. Harvest titer values of 29 soy hydrolysate lots with production yield between 490 and 1,350 mg/L were obtained from shake flask models or from manufacture engineering runs. The soy hydrolysate samples were measured by near-infrared (NIR) in reflectance mode using an infrared fiber optic probe. The fiber optic probe could easily enable in situ measurement of the soy hydrolysates for convenient raw material screening. The best PLS calibration has a determination coefficient of R (2) = 0.887 utilizing no spectral preprocessing, the two spectral ranges of 10,000-5,376 cm(-1) and 4,980-4,484 cm(-1), and a rank of 6 factors. The cross-validation of the model resulted in a determination coefficient of R (2) = 0.741 between the predicted and actual titer values with an average standard deviation of 72 mg/L. Compared with the resource demanding shake flask model, the combination of NIR and chemometric modeling provides a convenient method for soy hydrolysate screening with the advantage of fast speed, low cost and non-destructive.

  20. Definition of culture conditions for Arxula adeninivorans, a rational basis for studying heterologous gene expression in this dimorphic yeast.

    PubMed

    Stöckmann, Christoph; Palmen, Thomas G; Schroer, Kirsten; Kunze, Gotthard; Gellissen, Gerd; Büchs, Jochen

    2014-06-01

    The yeast Arxula adeninivorans is considered to be a promising producer of recombinant proteins. However, growth characteristics are poorly investigated and no industrial process has been established yet. Though of vital interest for strain screening and production processes, rationally defined culture conditions remain to be developed. A cultivation system was evolved based on targeted sampling and mathematical analysis of rationally designed small-scale cultivations in shake flasks. The oxygen and carbon dioxide transfer rates were analyzed as conclusive online parameters. Oxygen limitation extended cultivation and led to ethanol formation in cultures supplied with glucose. Cultures were inhibited at pH-values below 2.8. The phosphorus demand was determined as 1.55 g phosphorus per 100 g cell dry weight. Synthetic SYN6 medium with 20 g glucose l(-1) was optimized for cultivation in shake flasks by buffering at pH 6.4 with 140 mmol MES l(-1). Optimized SYN6 medium and operating conditions provided non-limited cultivations without by-product formation. A maximal specific growth rate of 0.32 h(-1) and short fermentations of 15 h were achieved. A pH optimum curve was derived from the oxygen transfer rates of differently buffered cultures, showing maximal growth between pH 2.8 and 6.5. Furthermore, it was shown that the applied medium and cultivation conditions were also suitable for non-limiting growth and product formation of a genetically modified A. adeninivorans strain expressing a heterologous phytase.

  1. Engineering of a Stable Whole-Cell Biocatalyst Capable of (S)-Styrene Oxide Formation for Continuous Two-Liquid-Phase Applications

    PubMed Central

    Panke, Sven; de Lorenzo, Víctor; Kaiser, Arnë; Witholt, Bernard; Wubbolts, Marcel G.

    1999-01-01

    Recombinant strains of Pseudomonas putida KT2440 carrying genetic expression cassettes with xylene oxygenase- and styrene monooxygenase-encoding genes on their chromosomes could be induced in shaking-flask experiments to specific activities that rivaled those of multicopy-plasmid-based Escherichia coli recombinants. Such strains maintained the introduced styrene oxidation activity in continuous two-liquid-phase cultures for at least 100 generations, although at a lower level than in the shaking-flask experiments. The data suggest that placement of target genes on the chromosome might be a suitable route for the construction of segregationally stable and highly active whole-cell biocatalysts. PMID:10584030

  2. Influence of the mechanical environment on the engineering of mineralised tissues using human dental pulp stem cells and silk fibroin scaffolds.

    PubMed

    Woloszyk, Anna; Holsten Dircksen, Sabrina; Bostanci, Nagihan; Müller, Ralph; Hofmann, Sandra; Mitsiadis, Thimios A

    2014-01-01

    Teeth constitute a promising source of stem cells that can be used for tissue engineering and regenerative medicine purposes. Bone loss in the craniofacial complex due to pathological conditions and severe injuries could be treated with new materials combined with human dental pulp stem cells (hDPSCs) that have the same embryonic origin as craniofacial bones. Optimising combinations of scaffolds, cells, growth factors and culture conditions still remains a great challenge. In the present study, we evaluate the mineralisation potential of hDPSCs seeded on porous silk fibroin scaffolds in a mechanically dynamic environment provided by spinner flask bioreactors. Cell-seeded scaffolds were cultured in either standard or osteogenic media in both static and dynamic conditions for 47 days. Histological analysis and micro-computed tomography of the samples showed low levels of mineralisation when samples were cultured in static conditions (0.16±0.1 BV/TV%), while their culture in a dynamic environment with osteogenic medium and weekly µCT scans (4.9±1.6 BV/TV%) significantly increased the formation of homogeneously mineralised structures, which was also confirmed by the elevated calcium levels (4.5±1.0 vs. 8.8±1.7 mg/mL). Molecular analysis of the samples showed that the expression of tooth correlated genes such as Dentin Sialophosphoprotein and Nestin were downregulated by a factor of 6.7 and 7.4, respectively, in hDPSCs when cultured in presence of osteogenic medium. This finding indicates that hDPSCs are able to adopt a non-dental identity by changing the culture conditions only. Also an increased expression of Osteocalcin (1.4x) and Collagen type I (1.7x) was found after culture under mechanically dynamic conditions in control medium. In conclusion, the combination of hDPSCs and silk scaffolds cultured under mechanical loading in spinner flask bioreactors could offer a novel and promising approach for bone tissue engineering where appropriate and rapid bone regeneration in mechanically loaded tissues is required.

  3. Enhanced Biosynthesis of Withanolides by Elicitation and Precursor Feeding in Cell Suspension Culture of Withania somnifera (L.) Dunal in Shake-Flask Culture and Bioreactor

    PubMed Central

    Sivanandhan, Ganeshan; Selvaraj, Natesan; Ganapathi, Andy; Manickavasagam, Markandan

    2014-01-01

    The present study investigated the biosynthesis of major and minor withanolides of Withania somnifera in cell suspension culture using shake-flask culture and bioreactor by exploiting elicitation and precursor feeding strategies. Elicitors like cadmium chloride, aluminium chloride and chitosan, precursors such as cholesterol, mevalonic acid and squalene were examined. Maximum total withanolides detected [withanolide A (7606.75 mg), withanolide B (4826.05 mg), withaferin A (3732.81 mg), withanone (6538.65 mg), 12 deoxy withanstramonolide (3176.63 mg), withanoside IV (2623.21 mg) and withanoside V (2861.18 mg)] were achieved in the combined treatment of chitosan (100 mg/l) and squalene (6 mM) along with 1 mg/l picloram, 0.5 mg/l KN, 200 mg/l L-glutamine and 5% sucrose in culture at 4 h and 48 h exposure times respectively on 28th day of culture in bioreactor. We obtained higher concentrations of total withanolides in shake-flask culture (2.13-fold) as well as bioreactor (1.66-fold) when compared to control treatments. This optimized protocol can be utilized for commercial level production of withanolides from suspension culture using industrial bioreactors in a short culture period. PMID:25089711

  4. Culture of prostate epithelial cells of the rhesus monkey on extracellular matrix substrate: influence of steroids and insulin-like growth factors.

    PubMed

    Udayakumar, T S; Jeyaraj, D A; Rajalakshmi, M; Sharma, R S

    1999-09-01

    Rhesus monkey prostate epithelial cells from the cranial lobe were isolated and cultured in flasks coated either with collagen IV or laminin. The effects of stromal cell medium, androgens and growth factors on cell number, thymidine incorporation and secretory activity were assessed. The results indicate that dihydrotestosterone (DHT) and androstenedione have stimulatory influences on cell proliferation and secretion in coated flasks. DHT was more effective in increasing cell number but the induction of secretory activity was similar with both steroids. The combination of IGF-I and -II resulted in inducing better cell proliferation and secretory activity than the individual IGFs but, of the two IGFs, IGF-I was more effective than IGF-II. DHT with IGFs was more potent in inducing proliferation, differentiation and secretion than androstenedione. Even in the absence of steroids or growth factors, colony formation and confluence occurred in coated flasks but cell differentiation and secretion only to a limited extent. In conclusion, we were able to establish an in vitro primary culture of prostate epithelial cells from rhesus monkey using extracellular matrix proteins, steroids and growth factors as additional supplements. This culture system may be useful to study prostate cell physiology and to identify drugs that can inhibit cell proliferation.

  5. Production of Laccase by Recombinant Yarrowia lipolytica from Molasses: Bioprocess Development Using Statistical Modeling and Increase Productivity in Shake-Flask and Bioreactor Cultures.

    PubMed

    Darvishi, Farshad; Moradi, Marzieh; Madzak, Catherine; Jolivalt, Claude

    2017-03-01

    Laccases are used in numerous applications, from green degradation of various xenobiotic compounds, waste detoxification, textile dye bleaching, and delignification of lignocellulose materials to biofuel production. In this study, the recombinant Yarrowia lipolytica YL4 strain carrying the white-rot fungus Trametes versicolor laccase IIIb gene was used for laccase production from beet molasses as an agro-industrial residue. Response surface methodology was used to statistical optimization of the production of laccase by Y. lipolytica using an industrial medium containing molasses which allows a six times increase in laccase activity compared to primary medium contains glucose after 144 h. In bioreactor cultivation after 48 h, laccase production reached to 3.7- and 22.5-fold more than optimized and primary media in shake-flask cultures, respectively. Laccase productivity in bioreactor (0.0937 U/h) was higher than shake-flask culture (0.0084 U/h). The present study provides valuable information about statistical optimization of bioprocess development for cost-effective production of laccase and other heterologous proteins in Y. lipolytica from beet molasses as sole carbon source, thus allowing the valorization and decreasing environmental pollution of this agro-industrial waste.

  6. Microarray platform affords improved product analysis in mammalian cell growth studies

    PubMed Central

    Li, Lingyun; Migliore, Nicole; Schaefer, Eugene; Sharfstein, Susan T.; Dordick, Jonathan S.; Linhardt, Robert J.

    2014-01-01

    High throughput (HT) platforms serve as cost-efficient and rapid screening method for evaluating the effect of cell culture conditions and screening of chemicals. The aim of the current study was to develop a high-throughput cell-based microarray platform to assess the effect of culture conditions on Chinese hamster ovary (CHO) cells. Specifically, growth, transgene expression and metabolism of a GS/MSX CHO cell line, which produces a therapeutic monoclonal antibody, was examined using microarray system in conjunction with conventional shake flask platform in a non-proprietary medium. The microarray system consists of 60 nl spots of cells encapsulated in alginate and separated in groups via an 8-well chamber system attached to the chip. Results show the non-proprietary medium developed allows cell growth, production and normal glycosylation of recombinant antibody and metabolism of the recombinant CHO cells in both the microarray and shake flask platforms. In addition, 10.3 mM glutamate addition to the defined base media results in lactate metabolism shift in the recombinant GS/MSX CHO cells in the shake flask platform. Ultimately, the results demonstrate that the high-throughput microarray platform has the potential to be utilized for evaluating the impact of media additives on cellular processes, such as, cell growth, metabolism and productivity. PMID:24227746

  7. The conversion of BTEX compounds by single and defined mixed cultures to medium-chain-length polyhydroxyalkanoate.

    PubMed

    Nikodinovic, Jasmina; Kenny, Shane T; Babu, Ramesh P; Woods, Trevor; Blau, Werner J; O'Connor, Kevin E

    2008-09-01

    Here, we report the use of petrochemical aromatic hydrocarbons as a feedstock for the biotechnological conversion into valuable biodegradable plastic polymers--polyhydroxyalkanoates (PHAs). We assessed the ability of the known Pseudomonas putida species that are able to utilize benzene, toluene, ethylbenzene, p-xylene (BTEX) compounds as a sole carbon and energy source for their ability to produce PHA from the single substrates. P. putida F1 is able to accumulate medium-chain-length (mcl) PHA when supplied with toluene, benzene, or ethylbenzene. P. putida mt-2 accumulates mcl-PHA when supplied with toluene or p-xylene. The highest level of PHA accumulated by cultures in shake flask was 26% cell dry weight for P. putida mt-2 supplied with p-xylene. A synthetic mixture of benzene, toluene, ethylbenzene, p-xylene, and styrene (BTEXS) which mimics the aromatic fraction of mixed plastic pyrolysis oil was supplied to a defined mixed culture of P. putida F1, mt-2, and CA-3 in the shake flasks and fermentation experiments. PHA was accumulated to 24% and to 36% of the cell dry weight of the shake flask and fermentation grown cultures respectively. In addition a three-fold higher cell density was achieved with the mixed culture grown in the bioreactor compared to shake flask experiments. A run in the 5-l fermentor resulted in the utilization of 59.6 g (67.5 ml) of the BTEXS mixture and the production of 6 g of mcl-PHA. The monomer composition of PHA accumulated by the mixed culture was the same as that accumulated by single strains supplied with single substrates with 3-hydroxydecanoic acid occurring as the predominant monomer. The purified polymer was partially crystalline with an average molecular weight of 86.9 kDa. It has a thermal degradation temperature of 350 degrees C and a glass transition temperature of -48.5 degrees C.

  8. Potential bioremediation of mercury-contaminated substrate using filamentous fungi isolated from forest soil.

    PubMed

    Kurniati, Evi; Arfarita, Novi; Imai, Tsuyoshi; Higuchi, Takaya; Kanno, Ariyo; Yamamoto, Koichi; Sekine, Masahiko

    2014-06-01

    The use of filamentous fungi in bioremediation of heavy metal contamination has been developed recently. This research aims to observe the capability of filamentous fungi isolated from forest soil for bioremediation of mercury contamination in a substrate. Six fungal strains were selected based on their capability to grow in 25 mg/L Hg(2+)-contaminated potato dextrose agar plates. Fungal strain KRP1 showed the highest ratio of growth diameter, 0.831, thus was chosen for further observation. Identification based on colony and cell morphology carried out by 18S rRNA analysis gave a 98% match to Aspergillus flavus strain KRP1. The fungal characteristics in mercury(II) contamination such as range of optimum pH, optimum temperature and tolerance level were 5.5-7 and 25-35°C and 100 mg/L respectively. The concentration of mercury in the media affected fungal growth during lag phases. The capability of the fungal strain to remove the mercury(II) contaminant was evaluated in 100 mL sterile 10 mg/L Hg(2+)-contaminated potato dextrose broth media in 250 mL Erlenmeyer flasks inoculated with 10(8) spore/mL fungal spore suspension and incubation at 30°C for 7 days. The mercury(II) utilization was observed for flasks shaken in a 130 r/min orbital shaker (shaken) and non-shaken flasks (static) treatments. Flasks containing contaminated media with no fungal spores were also provided as control. All treatments were done in triplicate. The strain was able to remove 97.50% and 98.73% mercury from shaken and static systems respectively. A. flavus strain KRP1 seems to have potential use in bioremediation of aqueous substrates containing mercury(II) through a biosorption mechanism. Copyright © 2014 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. All rights reserved.

  9. Inverse modeling of CO2 sources and sinks using satellite observations of CO2 from TES and surface flask measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nassar, Ray; Jones, DBA; Kulawik, SS

    2011-01-01

    We infer CO2 surface fluxes using satellite observations of mid-tropospheric CO2 from the Tropospheric Emission Spectrometer (TES) and measurements of CO2 from surface flasks in a time-independent inversion analysis based on the GEOS-Chem model. Using TES CO2 observations over oceans, spanning 40 S 40 N, we find that the horizontal and vertical coverage of the TES and flask data are complementary. This complementarity is demonstrated by combining the datasets in a joint inversion, which provides better constraints than from either dataset alone, when a posteriori CO2 distributions are evaluated against independent ship and aircraft CO2 data. In particular, the jointmore » inversion offers improved constraints in the tropics where surface measurements are sparse, such as the tropical forests of South America. Aggregating the annual surface-to-atmosphere fluxes from the joint inversion for the year 2006 yields 1.13 0.21 PgC for the global ocean, 2.77 0.20 PgC for the global land biosphere and 3.90 0.29 PgC for the total global natural flux (defined as the sum of all biospheric, oceanic, and biomass burning contributions but excluding CO2 emissions from fossil fuel combustion). These global ocean and global land fluxes are shown to be near the median of the broad range of values from other inversion results for 2006. To achieve these results, a bias in TES CO2 in the Southern Hemisphere was assessed and corrected using aircraft flask data, and we demonstrate that our results have low sensitivity to variations in the bias correction approach. Overall, this analysis suggests that future carbon data assimilation systems can benefit by integrating in situ and satellite observations of CO2 and that the vertical information provided by satellite observations of mid-tropospheric CO2 combined with measurements of surface CO2, provides an important additional constraint for flux inversions.« less

  10. Methodology for enabling high-throughput simultaneous saccharification and fermentation screening of yeast using solid biomass as a substrate.

    PubMed

    Elliston, Adam; Wood, Ian P; Soucouri, Marie J; Tantale, Rachelle J; Dicks, Jo; Roberts, Ian N; Waldron, Keith W

    2015-01-01

    High-throughput (HTP) screening is becoming an increasingly useful tool for collating biological data which would otherwise require the employment of excessive resources. Second generation biofuel production is one such process. HTP screening allows the investigation of large sample sets to be undertaken with increased speed and cost effectiveness. This paper outlines a methodology that will enable solid lignocellulosic substrates to be hydrolyzed and fermented at a 96-well plate scale, facilitating HTP screening of ethanol production, whilst maintaining repeatability similar to that achieved at a larger scale. The results showed that utilizing sheets of biomass of consistent density (handbills), for paper, and slurries of pretreated biomass that could be pipetted allowed standardized and accurate transfers to 96-well plates to be achieved (±3.1 and 1.7%, respectively). Processing these substrates by simultaneous saccharification and fermentation (SSF) at various volumes showed no significant difference on final ethanol yields, either at standard shake flask (200 mL), universal bottle (10 mL) or 96-well plate (1 mL) scales. Substrate concentrations of up to 10% (w/v) were trialed successfully for SSFs at 1 mL volume. The methodology was successfully tested by showing the effects of steam explosion pretreatment on both oilseed rape and wheat straws. This methodology could be used to replace large shake flask reactions with comparatively fast 96-well plate SSF assays allowing for HTP experimentation. Additionally this method is compatible with a number of standardized assay techniques such as simple colorimetric, High-performance liquid chromatography (HPLC) and Nuclear magnetic resonance (NMR) spectroscopy. Furthermore this research has practical uses in the biorefining of biomass substrates for second generation biofuels and novel biobased chemicals by allowing HTP SSF screening, which should allow selected samples to be scaled up or studied in more detail.

  11. Blackbody Cavity for Calibrations at 200 to 273 K

    NASA Technical Reports Server (NTRS)

    Howell, Dane; Ryan, Robert; Ryan, Jim; Henderson, Doug; Clayton, Larry

    2004-01-01

    A laboratory blackbody cavity has been designed and built for calibrating infrared radiometers used to measure radiant temperatures in the range from about 200 to about 273 K. In this below-room-temperature range, scattering of background infrared radiation from room-temperature surfaces could, potentially, contribute significantly to the spectral radiance of the blackbody cavity, thereby contributing a significant error to the radiant temperature used as the calibration value. The present blackbody cavity is of an established type in which multiple reflections from a combination of conical and cylindrical black-coated walls are exploited to obtain an effective emissivity greater than the emissivity value of the coating material on a flat exposed surface. The coating material in this case is a flat black paint that has an emissivity of approximately of 0.91 in the thermal spectral range and was selected over other, higher-emissivity materials because of its ability to withstand thermal cycling. We found many black coatings cracked and flaked after thermal cycling due to differences in the coefficient of expansion differences. On the basis of theoretical calculations, the effective emissivity is expected to approach 0.999. The cylindrical/conical shell enclosing the cavity is machined from copper, which is chosen for its high thermal conductivity. In use, the shell is oriented vertically, open end facing up, and inserted in a Dewar flask filled with isopropyl alcohol/dry-ice slush. A flange at the open end of the shell is supported by a thermally insulating ring on the lip of the Dewar flask. The slush cools the shell (and thus the black-body cavity) to the desired temperature. Typically, the slush starts at a temperature of about 194 K. The slush is stirred and warmed by bubbling dry air or nitrogen through it, thereby gradually increasing the temperature through the aforementioned calibration range during an interval of several hours. The temperature of the slush is monitored by use of a precise thermocouple probe.

  12. Tailoring nutritional and process variables for hyperproduction of catalase from a novel isolated bacterium Geobacillus sp. BSS-7.

    PubMed

    Kauldhar, Baljinder Singh; Sooch, Balwinder Singh

    2016-01-14

    Catalase (EC 1.11.1.6) is one of the important industrial enzyme employed in diagnostic and analytical methods in the form of biomarkers and biosensors in addition to their enormous applications in textile, paper, food and pharmaceutical sectors. The present study demonstrates the utility of a newly isolated and adapted strain of genus Geobacillus possessing unique combination of several industrially important extremophilic properties for the hyper production of catalase. The bacterium can grow over a wide range of pH (3-12) and temperature (10-90 °C) with extraordinary capability to produce catalase. A novel extremophilic strain belonging to genus Geobacillus was exploited for the production of catalase by tailoring its nutritional requirements and process variables. One variable at a time traditional approach followed by computational designing was applied to customize the fermentation process. A simple fermentation media containing only three components namely sucrose (0.55 %, w/v), yeast extract (1.0 %, w/v) and BaCl2 (0.08 %, w/v) was designed for the hyperproduction of catalase. A controlled and optimum air supply caused a tremendous increase in the enzyme production on moving the bioprocess from the flask to bioreactor level. The present paper reports high quantum of catalase production (105,000 IU/mg of cells) in a short fermentation time of 12 h. To the best of our knowledge, there is no report in the literature that matches the performance of the developed protocol for the catalase production. This is the first serious study covering intracellular catalase production from thermophilic genus Geobacillus. An increase in intracellular catalase production by 214.72 % was achieved in the optimized medium when transferred from the shake flask to the fermenter level. The extraordinary high production of catalase from Geobacillus sp. BSS-7 makes the isolated strain a prospective candidate for bulk catalase production on an industrial scale.

  13. Biodegradation of Degradable Plastic Polyethylene by Phanerochaete and Streptomyces Species †

    PubMed Central

    Lee, Byungtae; Pometto, Anthony L.; Fratzke, Alfred; Bailey, Theodore B.

    1991-01-01

    The ability of lignin-degrading microorganisms to attack degradable plastics was investigated in pure shake flask culture studies. The degradable plastic used in this study was produced commercially by using the Archer-Daniels-Midland POLYCLEAN masterbatch and contained pro-oxidant and 6% starch. The known lignin-degrading bacteria Streptomyces viridosporus T7A, S. badius 252, and S. setonii 75Vi2 and fungus Phanerochaete chrysosporium were used. Pro-oxidant activity was accelerated by placing a sheet of plastic into a drying oven at 70°C under atmospheric pressure and air for 0, 4, 8, 12, 16, or 20 days. The effect of 2-, 4-, and 8-week longwave UV irradiation at 365 nm on plastic biodegradability was also investigated. For shake flask cultures, plastics were chemically disinfected and incubated-shaken at 125 rpm at 37°C in 0.6% yeast extract medium (pH 7.1) for Streptomyces spp. and at 30°C for the fungus in 3% malt extract medium (pH 4.5) for 4 weeks along with an uninoculated control for each treatment. Weight loss data were inconclusive because of cell mass accumulation. For almost every 70°C heat-treated film, the Streptomyces spp. demonstrated a further reduction in percent elongation and polyethylene molecular weight average when compared with the corresponding uninoculated control. Significant (P < 0.05) reductions were demonstrated for the 4- and 8-day heat-treated films by all three bacteria. Heat-treated films incubated with P. chrysosporium consistently demonstrated higher percent elongation and molecular weight average than the corresponding uninoculated controls, but were lower than the corresponding zero controls (heat-treated films without 4-week incubation). The 2- and 4-week UV-treated films showed the greatest biodegradation by all three bacteria. Virtually no degradation by the fungus was observed. To our knowledge, this is the first report demonstrating bacterial degradation of these oxidized polyethylenes in pure culture. PMID:16348434

  14. Measurements of evaporated perfluorocarbon during partial liquid ventilation by a zeolite absorber.

    PubMed

    Proquitté, Hans; Rüdiger, Mario; Wauer, Roland R; Schmalisch, Gerd

    2004-01-01

    During partial liquid ventilation (PLV) the knowledge of the quantity of exhaled perfluorocarbon (PFC) allows a continuous substitution of the PFC loss to achieve a constant PFC level in the lungs. The aim of our in vitro study was to determine the PFC loss in the mixed expired gas by an absorber and to investigate the effect of the evaporated PFC on ventilatory measurements. To simulate the PFC loss during PLV, a heated flask was rinsed with a constant airflow of 4 L min(-1) and PFC was infused by different speeds (5, 10, 20 mL h(-1)). An absorber filled with PFC selective zeolites was connected with the flask to measure the PFC in the gas. The evaporated PFC volume and the PFC concentration were determined from the weight gain of the absorber measured by an electronic scale. The PFC-dependent volume error of the CO2SMO plus neonatal pneumotachograph was measured by manual movements of a syringe with volumes of 10 and 28 mL with a rate of 30 min(-1). Under steady state conditions there was a strong correlation (r2 = 0.999) between the infusion speed of PFC and the calculated PFC flow rate. The PFC flow rate was slightly underestimated by 4.3% (p < 0.01). However, this bias was independent from PFC infusion rate. The evaporated PFC volume was precisely measured with errors < 1%. The volume error of the CO2SMO-Plus pneumotachograph increased with increasing PFC content for both tidal volumes (p < 0.01). However for PFC flow rates up to 20 mL/h the error of the measured tidal volumes was < 5%. PFC selective zeolites can be used to quantify accurately the evaporated PFC volume during PLV. With increasing PFC concentrations in the exhaled air the measurement errors of ventilatory parameters have to be taken into account.

  15. Biodegradation of degradable plastic polyethylene by phanerochaete and streptomyces species.

    PubMed

    Lee, B; Pometto, A L; Fratzke, A; Bailey, T B

    1991-03-01

    The ability of lignin-degrading microorganisms to attack degradable plastics was investigated in pure shake flask culture studies. The degradable plastic used in this study was produced commercially by using the Archer-Daniels-Midland POLYCLEAN masterbatch and contained pro-oxidant and 6% starch. The known lignin-degrading bacteria Streptomyces viridosporus T7A, S. badius 252, and S. setonii 75Vi2 and fungus Phanerochaete chrysosporium were used. Pro-oxidant activity was accelerated by placing a sheet of plastic into a drying oven at 70 degrees C under atmospheric pressure and air for 0, 4, 8, 12, 16, or 20 days. The effect of 2-, 4-, and 8-week longwave UV irradiation at 365 nm on plastic biodegradability was also investigated. For shake flask cultures, plastics were chemically disinfected and incubated-shaken at 125 rpm at 37 degrees C in 0.6% yeast extract medium (pH 7.1) for Streptomyces spp. and at 30 degrees C for the fungus in 3% malt extract medium (pH 4.5) for 4 weeks along with an uninoculated control for each treatment. Weight loss data were inconclusive because of cell mass accumulation. For almost every 70 degrees C heat-treated film, the Streptomyces spp. demonstrated a further reduction in percent elongation and polyethylene molecular weight average when compared with the corresponding uninoculated control. Significant (P < 0.05) reductions were demonstrated for the 4- and 8-day heat-treated films by all three bacteria. Heat-treated films incubated with P. chrysosporium consistently demonstrated higher percent elongation and molecular weight average than the corresponding uninoculated controls, but were lower than the corresponding zero controls (heat-treated films without 4-week incubation). The 2- and 4-week UV-treated films showed the greatest biodegradation by all three bacteria. Virtually no degradation by the fungus was observed. To our knowledge, this is the first report demonstrating bacterial degradation of these oxidized polyethylenes in pure culture.

  16. Secondary metabolism in simulated microgravity

    NASA Technical Reports Server (NTRS)

    Demain, A. L.; Fang, A.

    2001-01-01

    We have studied microbial secondary metabolism in a simulated microgravity (SMG) environment provided by NASA rotating-wall bioreactors (RWBs). These reactors were designed to simulate some aspects of actual microgravity that occur in space. Growth and product formation were observed in SMG in all cases studied, i.e., Bacillus brevis produced gramicidin S (GS), Streptomyces clavuligerus made beta-lactam antibiotics, Streptomyces hygroscopicus produced rapamycin, and Escherichia coli produced microcin B17 (MccB17). Of these processes, only GS production was unaffected by SMG; production of the other three products was inhibited. This was determined by comparison with performance in an RWB positioned in a different mode to provide a normal gravity (NG) environment. Carbon source repression by glycerol of the GS process, as observed in shaken flasks, was not observed in the RWBs, whether operated in the SMG or NG mode. The same phenomenon occurred in the case of MccB17 production, with respect to glucose repression. Thus, the negative effects of carbon source on GS and beta-lactam formation are presumably dependent on shear, turbulence, and/or vessel geometry, but not on gravity. Stimulatory effects of phosphate and the precursor L-lysine on beta-lactam antibiotic production, as observed in flasks, also occurred in SMG. An almost complete shift in the localization of produced MccB17 from cells to extracellular medium was observed when E. coli was grown in the RWB under SMG or NG. If a plastic bead was placed in the RWB, accumulation became cellular, as it is in shaken flasks, indicating that sheer stress favors a cellular location. In the case of rapamycin, the same type of shift was observed, but it was less dramatic, i.e., growth in the RWB under SMG shifted the distribution of produced rapamycin from 2/3 cellular:1/3 extracellular to 1/3 cellular:2/3 extracellular. Stress has been shown to induce or promote secondary metabolism in a number of other microbial systems. RWBs provide a low stress SMG environment, which, however, supports only poor production of MccB17, as compared to production in shaken flasks. We wondered whether the poor production in RWBs under SMG is due to the low level of stress, and whether increasing stress in the RWBs would raise the amount of MccB17 formed. We found that increasing shear stress by adding a single Teflon bead to the RWB improved MccB17 production. Although shear stress seems to have a marked positive effect on MccB17 production in SMG, addition of various concentrations of ethanol to RWBs (or to shaken flasks) failed to increase MccB17 production. Ethanol stress merely decreased production and, at higher concentrations, inhibited growth. Interestingly, cells growing in the RWB were much more resistant to the growth- and production-inhibitory effects of ethanol than cells growing in shaken flasks. With respect to S. hygroscopicus, addition of Teflon beads to the RWB reversed the inhibition of growth, but rapamycin production was still markedly inhibited, and the distribution did not revert back to a preferential cellular site.

  17. Expression of cholera toxin under non-AKI conditions in Vibrio cholerae El Tor induced by increasing the exposed surface of cultures.

    PubMed

    Sánchez, Joaquín; Medina, Gerardo; Buhse, Thomas; Holmgren, Jan; Soberón-Chavez, Gloria

    2004-03-01

    The regulatory systems controlling expression of the ctxAB genes encoding cholera toxin (CT) in the classical and El Tor biotypes of pathogenic Vibrio cholerae have been characterized and found to be almost identical. Notwithstanding this, special in vitro conditions, called AKI conditions, are required for El Tor bacteria to produce CT. The AKI conditions involve biphasic cultures. In phase 1 the organism is grown in a still tube for 4 h. In phase 2 the medium is poured into a flask to continue growth with shaking. Virtually no expression of CT occurs if this protocol is not followed. Here we demonstrated that CT expression takes place in single-phase still cultures if the volume-to-surface-area ratio is decreased, both under air and under an inert atmosphere. The expression of key genes involved in the regulation of CT production was analyzed, and we found that the expression pattern closely resembles the in vivo expression pattern.

  18. Breathing gas perfluorocarbon measurements using an absorber filled with zeolites.

    PubMed

    Proquitté, H; Rüdiger, M; Wauer, R R; Schmalisch, G

    2003-11-01

    Perfluorocarbon (PFC) has been widely used in the treatment of respiratory diseases; however, PFC content of the breathing gases remains unknown. Therefore, we developed an absorber using PFC selective zeolites for PFC measurement in gases and investigated its accuracy. To generate a breathing gas with different PFC contents a heated flask was rinsed with a constant air flow of 4 litre x min(-1) and 1, 5, 10, and 20 ml of PFC were infused over 20 min using an infusor. The absorber was placed on an electronic scale and the total PFC volume was calculated from the weight gain. Steady-state increase in weight was achieved 3.5 min after stopping the infusion. The calculated PFC volume was slightly underestimated but the measuring error did not exceed -1% for PFC less than 1 ml. The measurement error decreased with increasing PFC volume. This zeolite absorber is an accurate method to quantitatively determine PFC in breathing gases and can be used as a reference method to validate other PFC sensors.

  19. Effects of iodinated contrast agent, xylocaine and gadolinium concentration on the signal emitted in magnetic resonance arthrography: a samples study*

    PubMed Central

    da Silva, Yvana Lopes Pinheiro; Costa, Rita Zanlorensi Visneck; Pinho, Kátia Elisa Prus; Ferreira, Ricardo Rabello; Schuindt, Sueliton Miyamoto

    2015-01-01

    Objective To investigate the effects of dilution of paramagnetic contrast agent with iodinated contrast and xylocaine on the signal intensity during magnetic resonance arthrography, and to improve the paramagnetic contrast agent concentration utilized in this imaging modality. Materials and Methods Samples specially prepared for the study with three different concentrations of paramagnetic contrast agent diluted in saline, iodinated contrast agent and xylocaine were imaged with fast spin echo T1-weighted sequences with fat saturation. The samples were placed into flasks and graphical analysis of the signal intensity was performed as a function of the paramagnetic contrast concentration. Results As compared with samples of equal concentrations diluted only with saline, the authors have observed an average signal intensity decrease of 20.67% for iodinated contrast agent, and of 28.34% for xylocaine. However, the increased gadolinium concentration in the samples caused decrease in signal intensity with all the dilutions. Conclusion Minimizing the use of iodinated contrast media and xylocaine and/or the use of a gadolinium concentration of 2.5 mmol/L diluted in saline will improve the sensitivity of magnetic resonance arthrography. PMID:25987746

  20. Continued emissions of carbon tetrachloride from the United States nearly two decades after its phaseout for dispersive uses

    PubMed Central

    Hu, Lei; Montzka, Stephen A.; Miller, Ben R.; Andrews, Arlyn E.; Miller, John B.; Lehman, Scott J.; Sweeney, Colm; Miller, Scot M.; Thoning, Kirk; Siso, Carolina; Atlas, Elliot L.; Blake, Donald R.; de Gouw, Joost; Gilman, Jessica B.; Dutton, Geoff; Elkins, James W.; Hall, Bradley; Chen, Huilin; Fischer, Marc L.; Mountain, Marikate E.; Nehrkorn, Thomas; Biraud, Sebastien C.; Moore, Fred L.; Tans, Pieter

    2016-01-01

    National-scale emissions of carbon tetrachloride (CCl4) are derived based on inverse modeling of atmospheric observations at multiple sites across the United States from the National Oceanic and Atmospheric Administration’s flask air sampling network. We estimate an annual average US emission of 4.0 (2.0–6.5) Gg CCl4 y−1 during 2008–2012, which is almost two orders of magnitude larger than reported to the US Environmental Protection Agency (EPA) Toxics Release Inventory (TRI) (mean of 0.06 Gg y−1) but only 8% (3–22%) of global CCl4 emissions during these years. Emissive regions identified by the observations and consistently shown in all inversion results include the Gulf Coast states, the San Francisco Bay Area in California, and the Denver area in Colorado. Both the observation-derived emissions and the US EPA TRI identified Texas and Louisiana as the largest contributors, accounting for one- to two-thirds of the US national total CCl4 emission during 2008–2012. These results are qualitatively consistent with multiple aircraft and ship surveys conducted in earlier years, which suggested significant enhancements in atmospheric mole fractions measured near Houston and surrounding areas. Furthermore, the emission distribution derived for CCl4 throughout the United States is more consistent with the distribution of industrial activities included in the TRI than with the distribution of other potential CCl4 sources such as uncapped landfills or activities related to population density (e.g., use of chlorine-containing bleach). PMID:26929368

  1. Use of 222Rn as natural tracer for LNAPL quantification and recovery efficiency in a crude-oil contaminated aquifer

    NASA Astrophysics Data System (ADS)

    Ponsin, Violaine; Chablais, Amélie; Dumont, Julien; Cardetti, Marc; Radakovitch, Olivier; Höhener, Patrick

    2014-05-01

    In august 2009, five hectares of the pristine gravel aquifer of Crau in southern France were contaminated by 5,100 m3 of crude oil due to the sudden break of a pipeline. The remediation of this site is still ongoing and consists in replacement and off-site disposal of contaminated topsoils, plume management by hydraulic groundwater barriers with re-injection of activated charcoal-treated waters, and dual-phase LNAPL extraction in the source zone. It is anticipated to stop these remediation actions when the rate of hydrocarbon extraction becomes inefficient. The volume of LNAPL is estimated between 100 and 1000 m3. A more accurate estimation is needed for the implementation of natural attenuation once physical treatment is discontinued. 222Rn has been introduced as a natural tracer for the quantification of LNAPL saturation in porous media under natural gradient conditions (Hunkeler et al., 1997; Semprini et al., 2000; Schubert et al., 2007). The objective of this study was to investigate whether 222Rn in groundwater can be used as a tracer for LNAPL quantification at a field site treated by LNAPL removal. To this end, groundwater samples were obtained in pristine monitoring wells from upgradient the contamination using submersible electric pumps, and in LNAPL recovery wells. There, samples were obtained from the tap on the hard PVC tubing used for pumping groundwater to the treatment facility. For 222Rn analysis, flasks of 250 mL were gently filled and were capped thereafter without permitting air bubbles. The flasks were analysed within 6 to 24 hours. The 222Rn activity of groundwater was measured by a Rn detector (RAD7-Durridge, Co. Inc.). The measurements were spaced over more than 15 months in order to account for seasonal changes. Each well was sampled at least 3 times. In pristine groundwater, the radon activity was relatively constant and remained always > 14 Bq/L. The radon activities in the groundwater of source zone wells were also relatively constant and the mean activities were generally significantly lower than upgradient. This is due to partitioning into the oil phase. Decreases were correlated with NAPL recovery efficiency. The laboratory-determined crude oil-water partitioning coefficient of 38,5 ± 2,9 was used for estimating LNAPL saturation in each recovery well. However, extrapolations of LNAPL saturations to whole-site oil volume estimations are difficult since at low water tables, the volume in the capillary fringe is not assessed. Nevertheless, we find that 222Rn is a useful and cheap groundwater tracer for finding zones of good LNAPL recovery in a heavily pumped aquifer. Hunkeler, D., E. Hoehn, P. Höhener and J. Zeyer, 1997. 222Rn as a partitioning tracer to detect mineral oil contaminations: laboratory experiments and field study. Environmental Science and Technology 31, 3180-3187. Semprini, L., O.S. Hopkins and B.R. Tasker, 2000. Laboratory, field and modeling studies of radon-222 as a natural tracer for monitoring NAPL contamination. Transport in Porous Media 38, 223-240. Schubert, M., A. Paschke, S. Lau, W. Geyer and K. Knöller, 2007. Radon as a naturally occurring tracer for the assessment of residual NAPL contamination of aquifers. Environmental Pollution 145, 920-927.

  2. Inventory Control.

    ERIC Educational Resources Information Center

    Byrum, David L., Ed.

    1984-01-01

    Describes an electronic thermometer using a precision temperature sensor (includes detailed schematic of circuits) and inexpensive ring holders for round-bottomed flasks. Also describes a method for reducing funnel breakage. (JN)

  3. A unique noninvasive approach to monitoring dissolved O2 and CO2 in cell culture.

    PubMed

    Chatterjee, Madhubanti; Ge, Xudong; Uplekar, Shaunak; Kostov, Yordan; Croucher, Leah; Pilli, Manohar; Rao, Govind

    2015-01-01

    Although online monitoring of dissolved oxygen (DO) and carbon dioxide (DCO2 ) is highly desirable in bioprocesses, small-scale bioreactors are usually not monitored due to the lack of suitable sensors. Traditional electrochemical sensors are usually not used because they are bulky and invasive. Disposable optical sensors are small and only partially invasive, but there are concerns regarding the toxicity of the patch and the phototoxicity of the illuminating light. Here we present a novel, noninvasive, rate-based technique for monitoring DO and DCO2 in cell cultures. A silicone sampling loop which allowed the diffusion of O2 and CO2 through its wall was inserted inside a bioreactor, and then flushed with N2 until the CO2 and O2 inside the loop were completely removed. The gas inside the loop was then allowed to recirculate through gas impermeable tubing to the O2 and CO2 sensors. We have shown that by measuring the initial diffusion rate we were able to determine the partial pressures of the two gases in the culture. The technique could be readily automated and measurements could be made in minutes. It was tested in demonstration experiments by growing murine hybridoma cells in a T-flask and a spinner-flask at 37°C. The results were comparable to those measured with commercially available fluorescence-based patch sensors. These results show that the rate-based method is an effective way to monitor small-scale cell cultures. This measurement mechanism can be easily built into disposable cell culture vessels for facile use. © 2014 Wiley Periodicals, Inc.

  4. Scale-up laccase production from Trametes versicolor stimulated by vanillic acid.

    PubMed

    Wang, Ke-Feng; Hu, Jian-Hua; Guo, Chen; Liu, Chun-Zhao

    2016-07-01

    An efficient strategy for laccase production in Trametes versicolor cultures was developed using vanillic acid as the inducer. The optimized vanillic acid treatment strategy consisted of exposing 2-day-old mycelia cultures to 80 mg/L vanillic acid. After 4 days, laccase activity of 588.84 U/L was achieved in flasks which represented a 1.79-fold increase compared to the control. In 200-L airlift bioreactor, the maximal laccase activity reached up to 785.12 U/L using the optimized vanillic acid treatment strategy. The zymograms of culture supernatants revealed three bands with laccase activity, among which Lac1 and Lac2 were abundant laccase isoforms constitutively expressed, and Lac3 was an inducible isozyme by vanillic acid. The results of real-time quantitative PCR showed that the transcription level of lcc in T. versicolor cultures grown with vanillic acid for 7 days was about 5.64-fold greater than that without vanillic acid in flasks. In 200-L airlift bioreactor cultures of T. versicolor with addition of vanillic acid, the transcript level of lcc at day 7 was 2.62-fold higher than that in flasks with vanillic acid due to the good mass transfer and oxygen supply in the bioreactor system. This study provides a basis for understanding the induction mechanism of vanillic acid for laccase production and has good potential for industrial applications.

  5. Study of plant phototropic responses to different LEDs illumination in microgravity

    NASA Astrophysics Data System (ADS)

    Zyablova, Natalya; Berkovich, Yuliy A.; Skripnikov, Alexander; Nikitin, Vladimir

    2012-07-01

    The purpose of the experiment planned for Russian BION-M #1, 2012, biosatellite is research of Physcomitrella patens (Hedw.) B.S.G. phototropic responses to different light stimuli in microgravity. The moss was chosen as small-size higher plant. The experimental design involves five lightproof culture flasks with moss gametophores fixed inside the cylindrical container (diameter 120 mm; height 240 mm). The plants in each flask are illuminated laterally by one of the following LEDs: white, blue (475 nm), red (625 nm), far red (730 nm), infrared (950 nm). The gametophores growth and bending are captured periodically by means of five analogue video cameras and recorder. The programmable command module controls power supply of each camera and each light source, commutation of the cameras and functioning of video recorder. Every 20 minutes the recorder is sequentially connecting to one of the cameras. This results in a clip, containing 5 sets of frames in a row. After landing time-lapse films are automatically created. As a result we will have five time-lapse films covering transformations in each of the five culture flasks. Onground experiments demonstrated that white light induced stronger gametophores phototropic bending as compared to red and blue stimuli. The comparison of time-lapse recordings in the experiments will provide useful information to optimize lighting assemblies for space plant growth facilities.

  6. Portable x-ray fluorescence spectrometer for environmental monitoring of inorganic pollutants

    NASA Technical Reports Server (NTRS)

    Clark, III, Benton C. (Inventor); Thornton, Michael G. (Inventor)

    1991-01-01

    A portable x-ray fluorescence spectrometer has a portable sensor unit containing a battery, a high voltage power supply, an x-ray tube which produces a beam x-ray radiation directed toward a target sample, and a detector for fluorescent x-rays produced by the sample. If a silicon-lithium detector is used, the sensor unit also contains either a thermoelectric or thermochemical cooler, or a small dewar flask containing liquid nitrogen to cool the detector. A pulse height analyzer (PHA) generates a spectrum of data for each sample consisting of the number of fluorescent x-rays detected as a function of their energy level. The PHA can also store spectrum data for a number of samples in the field. A processing unit can be attached to the pulse height analyzer to upload and analyze the stored spectrum data for each sample. The processing unit provides a graphic display of the spectrum data for each sample, and provides qualitative and/or quantitative analysis of the elemental composition of the sample by comparing the peaks in the sample spectrum against known x-ray energies for various chemical elements. An optional filtration enclosure can be used to filter particles from a sample suspension, either in the form of a natural suspension or a chemically created precipitate. The sensor unit is then temporarily attached to the filtration unit to analyze the particles collected by the filter medium.

  7. Monitoring lipase/esterase activity by stopped flow in a sequential injection analysis system using p-nitrophenyl butyrate.

    PubMed

    Pliego, Jorge; Mateos, Juan Carlos; Rodriguez, Jorge; Valero, Francisco; Baeza, Mireia; Femat, Ricardo; Camacho, Rosa; Sandoval, Georgina; Herrera-López, Enrique J

    2015-01-27

    Lipases and esterases are biocatalysts used at the laboratory and industrial level. To obtain the maximum yield in a bioprocess, it is important to measure key variables, such as enzymatic activity. The conventional method for monitoring hydrolytic activity is to take out a sample from the bioreactor to be analyzed off-line at the laboratory. The disadvantage of this approach is the long time required to recover the information from the process, hindering the possibility to develop control systems. New strategies to monitor lipase/esterase activity are necessary. In this context and in the first approach, we proposed a lab-made sequential injection analysis system to analyze off-line samples from shake flasks. Lipase/esterase activity was determined using p-nitrophenyl butyrate as the substrate. The sequential injection analysis allowed us to measure the hydrolytic activity from a sample without dilution in a linear range from 0.05-1.60 U/mL, with the capability to reach sample dilutions up to 1000 times, a sampling frequency of five samples/h, with a kinetic reaction of 5 min and a relative standard deviation of 8.75%. The results are promising to monitor lipase/esterase activity in real time, in which optimization and control strategies can be designed.

  8. Monitoring Lipase/Esterase Activity by Stopped Flow in a Sequential Injection Analysis System Using p-Nitrophenyl Butyrate

    PubMed Central

    Pliego, Jorge; Mateos, Juan Carlos; Rodriguez, Jorge; Valero, Francisco; Baeza, Mireia; Femat, Ricardo; Camacho, Rosa; Sandoval, Georgina; Herrera-López, Enrique J.

    2015-01-01

    Lipases and esterases are biocatalysts used at the laboratory and industrial level. To obtain the maximum yield in a bioprocess, it is important to measure key variables, such as enzymatic activity. The conventional method for monitoring hydrolytic activity is to take out a sample from the bioreactor to be analyzed off-line at the laboratory. The disadvantage of this approach is the long time required to recover the information from the process, hindering the possibility to develop control systems. New strategies to monitor lipase/esterase activity are necessary. In this context and in the first approach, we proposed a lab-made sequential injection analysis system to analyze off-line samples from shake flasks. Lipase/esterase activity was determined using p-nitrophenyl butyrate as the substrate. The sequential injection analysis allowed us to measure the hydrolytic activity from a sample without dilution in a linear range from 0.05–1.60 U/mL, with the capability to reach sample dilutions up to 1000 times, a sampling frequency of five samples/h, with a kinetic reaction of 5 min and a relative standard deviation of 8.75%. The results are promising to monitor lipase/esterase activity in real time, in which optimization and control strategies can be designed. PMID:25633600

  9. Determination of mercury in agroindustrial samples by flow-injection cold vapor atomic absorption spectrometry using ion exchange and reductive elution.

    PubMed

    Gomes Neto, J A; Zara, L F; Rocha, J C; Santos, A; Dakuzaku, C S; Nóbrega, J A

    2000-03-06

    A flow-injection system with a Chelite-S(R) cationic resin packed minicolumn is proposed for the determination of trace levels of mercury in agroindustrial samples by cold vapor atomic absorption spectrometry. Improved sensitivity and selectivity are attained since mercuric ions are on-line concentrated whereas other potential interferents are discarded. With on-line reductive elution procedure, concentrated hydrochloric acid could be replaced by 10% w/v SnCl(2), in 6 M HCl as eluent. The reversed-intermittent stream either carries the atomic mercury to the flow cell in the forward direction or removes the residue from reactor/gas-liquid separator to a discarding flask in the opposite direction. Concentration and volume of reagent, acidity, flow rates, commutation times and potential interfering species were investigated. For 120 s preconcentration time, the proposed system handles about 25 samples h(-1) (50.0-500 ng l(-1)), consuming about 10 ml sample and 5 mg SnCl(2) per determination. The detection limit is 0.8 ng l(-1) and the relative standard deviation (RSD) (n=12) of a 76.7 ng l(-1) sample is about 5%. Results are in agreement with certified value of standard materials at 95% confidence level and good recoveries (97-128%) of spiked samples were found.

  10. Solid-substrate fermentation of alfalfa for enhanced protein recovery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bajracharya, R.; Madgett, R.E.

    1979-04-01

    Solid-substrate fermentations for extraction of protein from pressed alfalfa residues with Aspergillus Sp. QM 9994, Aspergillus niger QM 877, and Rhizopus nigricans QM 387 were conducted in shake flasks. Upon reimbibing and second pressing, total protein recovery from alfalfa was increased from 47.2% for control samples and up to 64.5% for fermented samples. Analysis of juice from fermented samples indicated the presence of cellulase as well as pectinase activities. Dialysis cultures of cellulase-producing fungi showed that total biomass production and solids consumption were much higher than those of a mutant strain lacking the ability to produce cellulase, indicating significant utilizationmore » of cellulosic materials in alfalfa. The biomass yields in the former case ranged from 39-47% based on total solids consumption. Since some of the cellulosic and other carbohydrate constituents in alfalfa may be converted into fungal protein, final alfalfa residues following protein extraction in a commercial process would be less bulky for storage and handling and would be more digestible as a nonruminant animal feed.« less

  11. Comparison of extraction techniques of robenidine from poultry feed samples.

    PubMed

    Wilga, Joanna; Wasik, Agata Kot-; Namieśnik, Jacek

    2007-10-31

    In this paper, effectiveness of six different commonly applied extraction techniques for the determination of robenidine in poultry feed has been compared. The sample preparation techniques included shaking, Soxhlet, Soxtec, ultrasonically assisted extraction, microwave - assisted extraction and accelerated solvent extraction. Comparison of these techniques was done with respect to the recovery extraction, temperature and time, reproducibility and solvent consumption. Every single extract was subjected to clean - up using aluminium oxide column (Pasteur pipette filled with 1g of aluminium oxide), from which robenidine was eluted with 10ml of methanol. The eluate from the clean-up column was collected in a volumetric flask, and finally it was analysed by HPLC-DAD-MS. In general, all extraction techniques were capable of isolating of robenidine from poultry feed, but the recovery obtained using modern extraction techniques was higher than that obtained using conventional techniques. In particular, accelerated solvent extraction was more superior to other techniques, which highlights the advantages of this sample preparation technique. However, in routine analysis, shaking and ultrasonically assisted extraction is still the preferred method for the solution of robenidine and other coccidiostatics.

  12. Integrated Field Analyses of Thermal Springs

    NASA Astrophysics Data System (ADS)

    Shervais, K.; Young, B.; Ponce-Zepeda, M. M.; Rosove, S.

    2011-12-01

    A group of undergraduate researchers through the SURE internship offered by the Southern California Earthquake Center (SCEC) have examined thermal springs in southern Idaho, northern Utah as well as mud volcanoes in the Salton Sea, California. We used an integrated approach to estimate the setting and maximum temperature, including water chemistry, Ipad-based image and data-base management, microbiology, and gas analyses with a modified Giggenbach sampler.All springs were characterized using GISRoam (tmCogent3D). We are performing geothermometry calculations as well as comparisons with temperature gradient data on the results while also analyzing biological samples. Analyses include water temperature, pH, electrical conductivity, and TDS measured in the field. Each sample is sealed and chilled and delivered to a water lab within 12 hours.Temperatures are continuously monitored with the use of Solinst Levelogger Juniors. Through partnership with a local community college geology club, we receive results on a monthly basis and are able to process initial data earlier in order to evaluate data over a longer time span. The springs and mudpots contained microbial organisms which were analyzed using methods of single colony isolation, polymerase chain reaction, and DNA sequencing showing the impact of the organisms on the springs or vice versa. Soon we we will collect gas samples at sites that show signs of gas. This will be taken using a hybrid of the Giggenbach method and our own methods. Drawing gas samples has proven a challenge, however we devised a method to draw out gas samples utilizing the Giggenbach flask, transferring samples to glass blood sample tubes, replacing NaOH in the Giggenbach flask, and evacuating it in the field for multiple samples using a vacuum pump. We also use a floating platform devised to carry and lower a levelogger, to using an in-line fuel filter from a tractor in order to keep mud from contaminating the equipment.The use of raster imagery on the iPad2 has drastically changed how we plan and conduct our sampling trips. Orthoimagery onto the iPad2 is viewed with GISRoam and we use that imagery to help guide us toward points that we wish to visit. GISRoam was used to plot spatially correlated data points while in the field, estimate latitude and longitude, and record aforementioned data. A key factor to our success is up to the minute collaboration between all participants. Google's suite of services provides phone number for landowners, web site hosting, and the most crucial implementation for sharing data in real time has been the beta google Fusion Table. This spreadsheet allows for the incorporation of images, sample data and GPS location to be displayed as a kml file to be viewed in Google maps. This ability to modify and recognize data points in real time has made us more effective in the field, and in documenting progress in the lab. This workflow has enabled us to sample over 30 springs in 2 months, find 10 new springs, and estimate Tmax for 14 sites.By the end of 3 months we anticipate having water chemistry, isotope samples, gas samples, and Tmax determinations for 30 springs in the two study areas.

  13. Development and evaluation of a suite of isotope reference gases for methane in air

    NASA Astrophysics Data System (ADS)

    Sperlich, Peter; Uitslag, Nelly A. M.; Richter, Jürgen M.; Rothe, Michael; Geilmann, Heike; van der Veen, Carina; Röckmann, Thomas; Blunier, Thomas; Brand, Willi A.

    2016-08-01

    Measurements from multiple laboratories have to be related to unifying and traceable reference material in order to be comparable. However, such fundamental reference materials are not available for isotope ratios in atmospheric methane, which led to misinterpretations of combined data sets in the past. We developed a method to produce a suite of synthetic CH4-in-air standard gases that can be used to unify methane isotope ratio measurements of laboratories in the atmospheric monitoring community. Therefore, we calibrated a suite of pure methane gases of different methanogenic origin against international referencing materials that define the VSMOW (Vienna Standard Mean Ocean Water) and VPDB (Vienna Pee Dee Belemnite) isotope scales. The isotope ratios of our pure methane gases range between -320 and +40 ‰ for δ2H-CH4 and between -70 and -40 ‰ for δ13C-CH4, enveloping the isotope ratios of tropospheric methane (about -85 and -47 ‰ for δ2H-CH4 and δ13C-CH4 respectively). Estimated uncertainties, including the full traceability chain, are < 1.5 ‰ and < 0.2 ‰ for δ2H and δ13C calibrations respectively. Aliquots of the calibrated pure methane gases have been diluted with methane-free air to atmospheric methane levels and filled into 5 L glass flasks. The synthetic CH4-in-air standards comprise atmospheric oxygen/nitrogen ratios as well as argon, krypton and nitrous oxide mole fractions to prevent gas-specific measurement artefacts. The resulting synthetic CH4-in-air standards are referred to as JRAS-M16 (Jena Reference Air Set - Methane 2016) and will be available to the atmospheric monitoring community. JRAS-M16 may be used as unifying isotope scale anchor for isotope ratio measurements in atmospheric methane, so that data sets can be merged into a consistent global data frame.

  14. Fluid mechanics of spinner-flask bioreactors

    NASA Astrophysics Data System (ADS)

    Sucosky, Philippe; Neitzel, G. Paul

    2000-11-01

    The dynamic environment within bioreactors used for in vitro tissue growth has been observed to affect the development of mammalian cells. Many studies have shown that moderate mechanical stress enhances growth of some tissues whereas high shear levels and turbulence seem to damage cells. In order to optimize the design and the operating conditions of bioreactors, it is important to understand the fluid-dynamic characteristics and to control the stress levels within these devices. The present research focuses on the characterization of the flow field within a spinner-flask bioreactor. The dynamic properties of the flow are investigated experimentally using particle-image velocimetry with a refractive-index-matched model. Phase-locked ensemble-averaging is employed to provide some information on the turbulence characteristics of the model culture medium in the vicinity of a model tissue construct.

  15. Mercury recycling in the United States in 2000

    USGS Publications Warehouse

    Brooks, William E.; Matos, Grecia R.

    2005-01-01

    Reclamation and recycling of mercury from used mercury- containing products and treatment of byproduct mercury from gold mining is vital to the continued, though declining, use of this metal. Mercury is reclaimed from mercury-containing waste by treatment in multistep high-temperature retorts-the mercury is volatized and then condensed for purification and sale. Some mercury-containing waste, however, may be landfilled, and landfilled material represents loss of a recyclable resource and a threat to the environment. Related issues include mercury disposal and waste management, toxicity and human health, and regulation of mercury releases in the environment. End-users of mercury-containing products may face fines and prosecution if these products are improperly recycled or not recycled. Local and State environmental regulations require adherence to the Resource Conservation and Recovery Act and the Comprehensive Environmental Response, Compensation, and Liability Act to regulate generation, treatment, and disposal of mercury-containing products. In the United States, several large companies and a number of smaller companies collect these products from a variety of sources and then reclaim and recycle the mercury. Because mercury has not been mined as a principal product in the United States since 1992, mercury reclamation from fabricated products has become the main source of mercury. Principal product mercury and byproduct mercury from mining operations are considered to be primary materials. Mercury may also be obtained as a byproduct from domestic or foreign gold-processing operations. In the early 1990s, U.S. manufacturers used an annual average that ranged from 500 to 600 metric tons of recycled and imported mercury for fabrication of automobile convenience switches, dental amalgam, fluorescent lamps, medical uses and thermometers, and thermostats. The amount now used for fabrication is estimated to be 200 metric tons per year or less. Much of the data on mercury is estimated because it is a low-volume commodity and its production, use, and disposal is difficult to track. The prices and volumes of each category of mercury-containing material may change dramatically from year to year. For example, the average price of mercury was approximately $150 per flask from 2000 until 2003 and then rose sharply to $650 per flask in fall 2004 and approximately $850 per flask in spring 2005. Since 1927, the common unit for measuring and pricing mercury has been the flask in order to conform to the system used at Almaden, Spain (Meyers, 1951). One flask weighs 34.5 kilograms, and 29 flasks of mercury are contained in a metric ton. In the United States, the chlorine-caustic soda industry, which is the leading end-user of elemental mercury, recycles most of its mercury in-plant as home scrap. Annual purchases of replacement mercury by the chlorine-caustic soda industry indicate that some mercury may be lost through evaporation to the environment, put into a landfill as industrial waste, or trapped within pipes in the plant. Impending closure of domestic and foreign mercury-cell chlorine-caustic soda plants and the shift to nonmercury technology for chlorine-caustic soda production could ultimately result in a significant volume of elemental mercury for recycling, sale, or storage. Globally, mercury is widely used in artisanal, or small-scale, gold mining. Most of that mercury is lost to the environment and is not recycled. The recycling rate for mercury was not available owing to insufficient data in 2000, and the efficiency of mercury recycling was estimated to be 62 percent.

  16. Observations of molecular hydrogen (H2) mixing ratio and stable isotopic composition at the Cabauw tall tower; very depleted source signature suggests microbial H2 production in Dutch pasture soil.

    NASA Astrophysics Data System (ADS)

    Batenburg, Anneke; Popa, Elena; Vermeulen, Alex; van den Bulk, Pim; Jongejan, Piet; Fisher, Rebecca; Lowry, Dave; Nisbet, Euan; Röckmann, Thomas

    2017-04-01

    Molecular hydrogen (H2), though not toxic or a greenhouse gas itself, may influence air quality and climate indirectly by affecting the atmosphere's oxidative capacity. So as increased use of hydrogen fuel is expected, a better understanding of the global, regional and local atmospheric H2 cycles is needed. Studying the stable isotopic composition of H2 (δD(H2)) is a promising way to achieve this. Since the start of this century, the isotope effects in H2 source and sink processes have been estimated, δD(H2) has been incorporated into chemical transport models, and larger sets of environmental observations of δD(H2) have appeared. The latter, however, were mostly obtained from samples collected in remote regions of the atmosphere, which is not sufficient to fully characterize the H2 cycle or to assess the possible environmental effects of H2 leakage in urbanized regions. To address this gap, flask samples were collected at the Cabauw tall tower at the CESAR site in the Netherlands. The air was sampled from inlets at 20, 60, 120, and 200 meter altitude for the analysis of H2 mixing ratio (χ(H2)) and δD(H2). More than 250 samples were collected and analysed over a period of four years. The H2 mixing ratios in the samples show frequent excursions to high values above the background. Previously published continuous χ(H2) observations at Cabauw and other (sub)urban sites showed a similar pattern. With the isotope observations, we can now see that these high χ(H2) excursions are accompanied by very low δD(H2) values; probably at least partly a result of anthropogenic emissions of deuterium(D)-depleted H2. However, with a simple "Keeling plot" analysis, we obtained an apparent source signature (-515 ± 26 ‰) that was much below the range of published values for H2 emissions from the combustion of fossil fuels. Since the result of the fit depended markedly on the quality selection of the samples that were included, we applied a bootstrap method to this fit to obtain a realistic picture of the uncertainty of the result. This showed a wide distribution with more than 99 % of the values below -400 ‰, suggesting that the H2 cycle at Cabauw is under the influence of a source mix that is much more D-depleted than currently accepted values for fossil fuel combustion. Since microbial production of very D-depleted H2 has been observed previously at Cabauw, we consider it likely that this contributes to the low apparent source signature. A comparison of the samples from different sampling heights shows that there is a significant shift to lower δD(H2) values at the lower sampling levels. This shows that the uptake of H2 by the soil, which preferentially removes "light" H2, is relatively weak at the site. It also points again to local to regional microbial production of H2, and possibly to differences between national vehicle fleets.

  17. Antifoam addition to shake flask cultures of recombinant Pichia pastoris increases yield

    PubMed Central

    2011-01-01

    Background Pichia pastoris is a widely-used host for recombinant protein production. Initial screening for both suitable clones and optimum culture conditions is typically carried out in multi-well plates. This is followed by up-scaling either to shake-flasks or continuously stirred tank bioreactors. A particular problem in these formats is foaming, which is commonly prevented by the addition of chemical antifoaming agents. Intriguingly, antifoams are often added without prior consideration of their effect on the yeast cells, the protein product or the influence on downstream processes such as protein purification. In this study we characterised, for the first time, the effects of five commonly-used antifoaming agents on the total amount of recombinant green fluorescent protein (GFP) secreted from shake-flask cultures of this industrially-relevant yeast. Results Addition of defined concentrations of Antifoam A (Sigma), Antifoam C (Sigma), J673A (Struktol), P2000 (Fluka) or SB2121 (Struktol) to shake-flask cultures of P. pastoris increased the total amount of recombinant GFP in the culture medium (the total yield) and in the case of P2000, SB2121 and J673A almost doubled it. When normalized to the culture density, the GFP specific yield (μg OD595-1) was only increased for Antifoam A, Antifoam C and J673A. Whilst none of the antifoams affected the growth rate of the cells, addition of P2000 or SB2121 was found to increase culture density. There was no correlation between total yield, specific yield or specific growth rate and the volumetric oxygen mass transfer coefficient (kLa) in the presence of antifoam. Moreover, the antifoams did not affect the dissolved oxygen concentration of the cultures. A comparison of the amount of GFP retained in the cell by flow cytometry with that in the culture medium by fluorimetry suggested that addition of Antifoam A, Antifoam C or J673A increased the specific yield of GFP by increasing the proportion secreted into the medium. Conclusions We show that addition of a range of antifoaming agents to shake flask cultures of P. pastoris increases the total yield of the recombinant protein being produced. This is not only a simple method to increase the amount of protein in the culture, but our study also provides insight into how antifoams interact with microbial cell factories. Two mechanisms are apparent: one group of antifoams (Antifoam A, Antifoam C and J673A) increases the specific yield of GFP by increasing the total amount of protein produced and secreted per cell, whilst the second (P2000 or SB2121) increases the total yield by increasing the density of the culture. PMID:21426555

  18. How-To-Do-It: Plant Regeneration.

    ERIC Educational Resources Information Center

    Pietraface, William J.

    1988-01-01

    Describes a procedure for the growth of tobacco plants in flasks. Demonstrates plant tissue culture manipulation, totipotency, and plant regeneration in approximately 12 weeks. Discusses methods, materials, and expected results. (CW)

  19. Spontaneously Generating Life in Your Classroom? Pasteur, Spallanzani and Science Process.

    ERIC Educational Resources Information Center

    Byington, Scott

    2001-01-01

    Presents an experiment that tests for spontaneous generation, or abiogenesis. Observes microbial growth in nutrient broth under seven different flask environments. Includes instructions for the methods. (YDS)

  20. Cross-section perimeter is a suitable parameter to describe the effects of different baffle geometries in shaken microtiter plates

    PubMed Central

    2014-01-01

    Background Biotechnological screening processes are performed since more than 8 decades in small scale shaken bioreactors like shake flasks or microtiter plates. One of the major issues of such reactors is the sufficient oxygen supply of suspended microorganisms. Oxygen transfer into the bulk liquid can in general be increased by introducing suitable baffles at the reactor wall. However, a comprehensive and systematic characterization of baffled shaken bioreactors has never been carried out so far. Baffles often differ in number, size and shape. The exact geometry of baffles in glass lab ware like shake flasks is very difficult to reproduce from piece to piece due to the hard to control flow behavior of molten glass during manufacturing. Thus, reproducibility of the maximum oxygen transfer capacity in such baffled shake flasks is hardly given. Results As a first step to systematically elucidate the general effect of different baffle geometries on shaken bioreactor performance, the maximum oxygen transfer capacity (OTRmax) in baffled 48-well microtiter plates as shaken model reactor was characterized. This type of bioreactor made of plastic material was chosen, as the exact geometry of the baffles can be fabricated by highly reproducible laser cutting. As a result, thirty different geometries were investigated regarding their maximum oxygen transfer capacity (OTRmax) and liquid distribution during shaking. The relative perimeter of the cross-section area as new fundamental geometric key parameter is introduced. An empirical correlation for the OTRmax as function of the relative perimeter, shaking frequency and filling volume is derived. For the first time, this correlation allows a systematic description of the maximum oxygen transfer capacity in baffled microtiter plates. Conclusions Calculated and experimentally determined OTRmax values agree within ± 30% accuracy. Furthermore, undesired out-of-phase operating conditions can be identified by using the relative perimeter as key parameter. Finally, an optimum well geometry characterized by an increased perimeter of 10% compared to the unbaffled round geometry is identified. This study may also assist to comprehensively describe and optimize the baffles of shake flasks in future. PMID:25093039

  1. pH-metric solubility. 2: correlation between the acid-base titration and the saturation shake-flask solubility-pH methods.

    PubMed

    Avdeef, A; Berger, C M; Brownell, C

    2000-01-01

    The objective of this study was to compare the results of a normal saturation shake-flask method to a new potentiometric acid-base titration method for determining the intrinsic solubility and the solubility-pH profiles of ionizable molecules, and to report the solubility constants determined by the latter technique. The solubility-pH profiles of twelve generic drugs (atenolol, diclofenac.Na, famotidine, flurbiprofen, furosemide, hydrochlorothiazide, ibuprofen, ketoprofen, labetolol.HCl, naproxen, phenytoin, and propranolol.HCl), with solubilities spanning over six orders of magnitude, were determined both by the new pH-metric method and by a traditional approach (24 hr shaking of saturated solutions, followed by filtration, then HPLC assaying with UV detection). The 212 separate saturation shake-flask solubility measurements and those derived from 65 potentiometric titrations agreed well. The analysis produced the correlation equation: log(1/S)titration = -0.063(+/- 0.032) + 1.025(+/- 0.011) log(1/S)shake-flask, s = 0.20, r2 = 0.978. The potentiometrically-derived intrinsic solubilities of the drugs were: atenolol 13.5 mg/mL, diclofenac.Na 0.82 microg/mL, famotidine 1.1 mg/ mL, flurbiprofen 10.6 microg/mL, furosemide 5.9 microg/mL, hydrochlorothiazide 0.70 mg/mL, ibuprofen 49 microg/mL, ketoprofen 118 microg/mL, labetolol.HCl 128 microg/mL, naproxen 14 microg/mL, phenytoin 19 microg/mL, and propranolol.HCl 70 microg/mL. The new potentiometric method was shown to be reliable for determining the solubility-pH profiles of uncharged ionizable drug substances. Its speed compared to conventional equilibrium measurements, its sound theoretical basis, its ability to generate the full solubility-pH profile from a single titration, and its dynamic range (currently estimated to be seven orders of magnitude) make the new pH-metric method an attractive addition to traditional approaches used by preformulation and development scientists. It may be useful even to discovery scientists in critical decision situations (such as calibrating computational prediction methods).

  2. NOAA Mobile Laboratory Measures Oil and Gas Emissions

    NASA Astrophysics Data System (ADS)

    Kofler, J. D.; Petron, G.; Dube, W. P.; Edwards, P. M.; Brown, S. S.; Geiger, F.; Patrick, L.; Crepinsek, S.; Chen, H.; Miller, B. R.; Montzka, S. A.; Lang, P. M.; Newberger, T.; Higgs, J. A.; Sweeney, C.; Guenther, D.; Karion, A.; Wolter, S.; Williams, J.; Jordan, A.; Tans, P. P.; Schnell, R. C.

    2012-12-01

    A van capable of continuous real time measurements of CH4 , CO2, CO, Water Vapor, Ozone, NO, NO2, Volatile Organic Compounds VOCs including aromatics and other traces gases was driven in the oil and gas fields of the Uintah Basin in northeastern Utah. Compressor Stations, processing plants, oil and gas well heads. Separators, condensate tanks, evaporation pond disposal facilities, holding tanks, hydraulic fracturing sites, gas pipelines and more were studied using the van. The mobile measurements provide a powerful tool to get to the source of the emissions and reveal the unique chemical signature of each of the stages and components of oil and gas production as well as the overall basin and background gas concentrations. In addition to a suite of gas analyzers, the van includes a meteorological system (temperature, humidity, and wind speed and direction), GPS tracking, flask sampling system and a batter power system. Aspects of the vans hardware, sampling methods and operations are discussed along with a few highlights of the measurements.

  3. A comparative study of pure and copper (Cu)-doped ZnO nanorods for antibacterial and photocatalytic applications with their mechanism of action

    NASA Astrophysics Data System (ADS)

    Bhuyan, Tamanna; Khanuja, Manika; Sharma, R.; Patel, S.; Reddy, M. R.; Anand, S.; Varma, A.

    2015-07-01

    The present study reports the synthesis of pure and Cu-doped ZnO nanorods for antibacterial and photocatalytic applications. The samples were synthesized by simple, low cost mechanical-assisted thermal decomposition process. The synthesized materials were characterized by scanning electron microscopy, UV-Visible spectroscopy, and photoluminescence studies. The antibacterial activity of characterized samples was determined against Gram-positive bacteria such as Staphylococcus aureus and Streptococcus pyogenes and Gram-negative bacteria such as Escherichia coli using shake flask method with respect to time. The significant antibacterial activity was perceived from scanning electron micrographs that clearly revealed bacterial cell lysis resulting in the release of cytoplasmic content followed by cell death. The degradation of methylene blue was used as a model organic dye for photocatalytic activity. The present study demonstrates the superior photocatalytic and antibacterial activity of Cu-doped ZnO nanorods with respect to pure ZnO nanorods.

  4. Application of statistical experimental methodology to optimize bioremediation of n-alkanes in aquatic environment.

    PubMed

    Zahed, Mohammad Ali; Aziz, Hamidi Abdul; Mohajeri, Leila; Mohajeri, Soraya; Kutty, Shamsul Rahman Mohamed; Isa, Mohamed Hasnain

    2010-12-15

    Response surface methodology (RSM) was employed to optimize nitrogen and phosphorus concentrations for removal of n-alkanes from crude oil contaminated seawater samples in batch reactors. Erlenmeyer flasks were used as bioreactors; each containing 250 mL dispersed crude oil contaminated seawater, indigenous acclimatized microorganism and different amounts of nitrogen and phosphorus based on central composite design (CCD). Samples were extracted and analyzed according to US-EPA protocols using a gas chromatograph. During 28 days of bioremediation, a maximum of 95% total aliphatic hydrocarbons removal was observed. The obtained Model F-value of 267.73 and probability F<0.0001 implied the model was significant. Numerical condition optimization via a quadratic model, predicted 98% n-alkanes removal for a 20-day laboratory bioremediation trial using nitrogen and phosphorus concentrations of 13.62 and 1.39 mg/L, respectively. In actual experiments, 95% removal was observed under these conditions. Copyright © 2010 Elsevier B.V. All rights reserved.

  5. Six years of atmospheric CO2 observations at Mt. Fuji recorded with a battery-powered measurement system

    NASA Astrophysics Data System (ADS)

    Nomura, Shohei; Mukai, Hitoshi; Terao, Yukio; Machida, Toshinobu; Nojiri, Yukihiro

    2017-03-01

    We developed a battery-powered carbon dioxide (CO2) measurement system for monitoring at the summit of Mt. Fuji (3776 m a.s.l.), which experiences very low temperatures (below -20 °C) and severe environmental conditions without access to gridded electricity for 10 months (from September to June). Our measurement system used 100 batteries to run the measurement unit during these months. These batteries were charged during the 2-month summer season when gridded electricity was available, using a specially designed automatic battery-charging system. We installed this system in summer 2009 at the Mt. Fuji weather station; observations of atmospheric CO2 concentration were taken through December 2015. Measurements were never interrupted by a lack of battery power except for two cases in which lightning damaged a control board. Thus we obtained CO2 data during about 94 % of the 6-year period. Analytical performances (stability and accuracy) were better than 0.1 ppm, as tested by checking working standards and comparisons with flask sampling.Observational results showed that CO2 mole fractions at Mt. Fuji demonstrated clear seasonal variation. The trend and the variability of the CO2 growth rate observed at Mt. Fuji were very similar to those of the Mauna Loa Observatory (MLO). Seasonally, the concentration at Mt. Fuji was 2-10 ppm lower in summer and 2-12 ppm higher in winter than those at MLO. The lower concentrations at Mt. Fuji in summer are mainly attributed to episodes of air mass transport from Siberia or China, where CO2 is taken up by the terrestrial biosphere. On the other hand, the relatively higher concentrations in winter seem to reflect the high percentage of air masses originating from China or Southeast Asia during this period, which carry increased anthropogenic carbon dioxide. These results show that Mt. Fuji is not very influenced by local sources but rather by the sources and sinks over a very large region.Thus we conclude that, as this system could provide stable measurement data with relatively easy operation for 6 years at Mt. Fuji, it could be a useful monitoring technique for remote background sites elsewhere.

  6. Measurements of Greenhouse Gases around the Sacramento Area: The Airborne Greenhouse Emissions Survey (AGES) Campaign

    NASA Astrophysics Data System (ADS)

    Karion, A.; Fischer, M. L.; Turnbull, J. C.; Sweeney, C.; Faloona, I. C.; Zagorac, N.; Guilderson, T. P.; Saripalli, S.; Sherwood, T.

    2009-12-01

    The state of California is leading the United States by enacting legislation (AB-32) to reduce greenhouse gas emissions to 1990 levels by 2020. The success of reduction efforts can be gauged with accurate emissions inventories and potentially verified with atmospheric measurements of greenhouse gases (GHGs) over time. Measurements of multiple GHGs and associated trace gas species in a specific region also provide information on emissions ratios for source apportionment. We conducted the Airborne Greenhouse Emissions Survey (AGES) campaign to determine emissions signature ratios for the sources that exist in the San Francisco Bay and Sacramento Valley areas. Specifically, we attempt to determine the emissions signatures of sources that influence ongoing measurements made at a tall-tower measurement site near Walnut Grove, CA. For two weeks in February and March of 2009, a Cessna 210 was flown throughout the Sacramento region, making continuous measurements of CO2, CH4, and CO while also sampling discrete flasks for a variety of additional tracers, including SF6, N2O, and 14C in CO2 (Δ14CO2). Flight paths were planned using wind predictions for each day to maximize sampling of sources whose emissions would also be sampled contemporaneously by the instrumentation at the Walnut Grove tower (WGC), part of the ongoing California Greenhouse Gas Emissions Measurement (CALGEM) project between NOAA/ESRL’s Carbon Cycle group and Lawrence Berkeley National Laboratory (LBNL). Flights were performed in two distinct patterns: 1) flying across a plume upwind and downwind of the Sacramento urban area, and 2) flying across the Sacramento-San Joaquin Delta from Richmond to Walnut Grove, a region consisting of natural wetlands as well as several power plants and refineries. Results show a variety of well-correlated mixing ratio signals downwind of Sacramento, documenting the urban signature emission ratios, while emissions ratios in the Delta region were more variable, likely due to the both natural and anthropogenic sources in that region. Periodic flask measurements of Δ14CO2 provide additional insight regarding the partitioning of CO2 emissions due to fossil fuel (deficient in 14C) from those of biospheric sources. A strong correlation between fossil-fuel CO2 and CO was measured downwind of Sacramento, suggesting that the continuous measurements of CO can be used to estimate a continuous profile of fossil-fuel CO2 enhancement in this region.

  7. Performance of a water suction system using hydrophilic fibrous cloth under low gravity and microgravity in parabolic flight.

    PubMed

    Tani, A; Saito, T; Kitaya, Y; Takahashi, H; Goto, E

    2000-06-01

    For suction of water from a water supply vessel including both water and air under microgravity and g-jitter conditions, a water suction system using hydrophilic fibrous cloth was developed and its performance was evaluated at 0.01-0.02 g-realized for 20 s by parabolic flight in an aircraft. Vessels used for the experiment were glass flasks and had a suction port for suction filtration. A piece of hydrophilic fibrous cloth was arranged along the inner surface of the vessels and the end was fixed to the suction port of the vessels. In vessel without hydrophilic cloths and containing 220 mL of water, the water did not move more than 5 mm along the inner surface and did not reach the suction port under low gravity. When hydrophilic cloths were used, on the other hand, water gathered onto the cloth surface, moved up along the cloth and reached the suction port under low gravity. The amount of water sucked from vessels varied with the amount of water in the vessel and the sectional area of hydrophilic cloths. When the vessels including both water and air were flown during parabolic flight (10(-4) g), water in the vessel moved along the cloth and a water film was formed on the cloth. These results indicated that it is possible to suck water using the fibrous cloth suction system under low gravity and microgravity conditions. Under low gravity conditions, it was difficult to suck water only. However, it is not necessary to separate water from air when the system is used for supplying water to plant root medium consisting of both liquid and gas phases.

  8. A hollow definitive obturator fabrication technique for management of partial maxillectomy.

    PubMed

    Patil, Pravinkumar Gajanan; Patil, Smita Pravinkumar

    2012-11-01

    Maxillary obturator prosthesis is the most frequent treatment option for management of partial or total maxillectomy. Heavy weight of the obturators is often a dislocating factor. Hollowing the prosthesis to reduce its weight is the well established fact. The alternate technique to hollow-out the prosthesis has been described in this article which is a variation of previously described processing techniques. A pre-shaped wax-bolus was incorporated inside the flasks during packing of the heat-polymerized acrylic resin to automatically create the hollow space. The processing technique described is a single step flasking procedure to construct a closed-hollow-obturator prosthesis as a single unit. To best understand the technique, this article describes management of a patient who had undergone partial maxillectomy secondary to squamous cell carcinoma rehabilitated with a hollow-obturator prosthesis.

  9. A hollow definitive obturator fabrication technique for management of partial maxillectomy

    PubMed Central

    Patil, Smita Pravinkumar

    2012-01-01

    Maxillary obturator prosthesis is the most frequent treatment option for management of partial or total maxillectomy. Heavy weight of the obturators is often a dislocating factor. Hollowing the prosthesis to reduce its weight is the well established fact. The alternate technique to hollow-out the prosthesis has been described in this article which is a variation of previously described processing techniques. A pre-shaped wax-bolus was incorporated inside the flasks during packing of the heat-polymerized acrylic resin to automatically create the hollow space. The processing technique described is a single step flasking procedure to construct a closed-hollow-obturator prosthesis as a single unit. To best understand the technique, this article describes management of a patient who had undergone partial maxillectomy secondary to squamous cell carcinoma rehabilitated with a hollow-obturator prosthesis. PMID:23236579

  10. Morphological changes in human melanoma cells following irradiation with thermal neutrons.

    PubMed

    Barkla, D H; Allen, B J; Brown, J K; Mountford, M; Mishima, Y; Ichihashi, M

    1989-01-01

    Morphological changes in two human melanoma cell lines, MM96 and MM418, following irradiation with thermal neutrons, were studied using light and electron microscopy. The results show that the response of human malignant melanoma cells to neutron irradiation is both cell line dependent and dose dependent, and that in any given cell line, some cells are more resistant to irradiation than others, thus demonstrating heterogeneity in respect to radiosensitivity. Cells repopulating MM96 flasks after irradiation were morphologically similar to the cells of origin whereas in MM418 flasks cells differentiated into five morphologically distinct subgroups and showed increased melanization. The results also show that radiation causes distinctive morphological patterns of damage although ultrastructural changes unique to the high LET particles released from boron 10 neutron capture are yet to be identified.

  11. Bench-scale evaluation of in situ bioremediation strategies for soil at a former manufactured gas plant site.

    PubMed

    Li, Jun; Pignatello, Joseph J; Smets, Barth F; Grasso, Domenico; Monserrate, Esteban

    2005-03-01

    We examined the biodegradation and desorption of a set of 15 polycyclic aromatic hydrocarbon (PAH) compounds in coal tar-contaminated soil at a former manufactured gas plant site to evaluate the feasibility of in situ bioremediation. Experiments were conducted in well-mixed aerobic soil suspensions containing various additives over a 93- to 106-d period. In general, both biotransformation and desorption decreased with PAH ring size, becoming negligible for the six-ring PAH compounds. Biodegradation by indigenous microorganisms was strongly accelerated by addition of inorganic nutrients (N, P, K, and trace metals). The rates of biotransformation of PAH compounds by indigenous microorganisms in nutrient-amended flasks outpaced their maximum (i.e., chelate-enhanced) rates of desorption to an infinite sink (Tenax) in sterilized systems run in parallel, suggesting that indigenous organisms facilitated desorption. Biodegradation by indigenous organisms in nutrient-amended flasks appeared to be unaffected by the addition of a site-derived bacterial enrichment culture, resulting in approximately 100-fold higher aromatic dioxygenase levels, and by the addition of 0.01 M chelating agent (citrate or pyrophosphate), although such chelating agents greatly enhanced desorption in microbially inactivated flasks. The strong ability of nutrients to enhance degradation of the bioavailable PAHs indicates that their persistence for many decades at this site likely results from nutrient-limited natural biodegradation, and it also suggests that an effective strategy for their bioremediation could consist simply of adding inorganic nutrients.

  12. Optimization of Ex Vivo Murine Bone Marrow Derived Immature Dendritic Cells: A Comparative Analysis of Flask Culture Method and Mouse CD11c Positive Selection Kit Method

    PubMed Central

    Salwe, Sukeshani; Kothari, Sweta; Chowdhary, Abhay; Deshmukh, Ranjana A.

    2018-01-01

    12–14 days of culturing of bone marrow (BM) cells containing various growth factors is widely used method for generating dendritic cells (DCs) from suspended cell population. Here we compared flask culture method and commercially available CD11c Positive Selection kit method. Immature BMDCs' purity of adherent as well as suspended cell population was generated in the decreasing concentration of recombinant-murine granulocyte-macrophage colony-stimulating factor (rmGM-CSF) in nontreated tissue culture flasks. The expression of CD11c, MHCII, CD40, and CD86 was measured by flow cytometry. We found significant difference (P < 0.05) between the two methods in the adherent cells population but no significant difference was observed between the suspended cell populations with respect to CD11c+ count. However, CD11c+ was significantly higher in both adhered and suspended cell population by culture method but kit method gave more CD11c+ from suspended cells population only. On the other hand, using both methods, immature DC expressed moderate level of MHC class II molecules as well as low levels of CD40 and CD86. Our findings suggest that widely used culture method gives the best results in terms of yield, viability, and purity of BMDCs from both adherent and suspended cell population whereas kit method works well for suspended cell population. PMID:29682352

  13. Simultaneous Extraction Optimization and Analysis of Flavonoids from the Flowers of Tabernaemontana heyneana by High Performance Liquid Chromatography Coupled to Diode Array Detector and Electron Spray Ionization/Mass Spectrometry

    PubMed Central

    Sathishkumar, Thiyagarajan; Baskar, Ramakrishnan; Aravind, Mohan; Tilak, Suryanarayanan; Deepthi, Sri; Bharathikumar, Vellalore Maruthachalam

    2013-01-01

    Flavonoids are exploited as antioxidants, antimicrobial, antithrombogenic, antiviral, and antihypercholesterolemic agents. Normally, conventional extraction techniques like soxhlet or shake flask methods provide low yield of flavonoids with structural loss, and thereby, these techniques may be considered as inefficient. In this regard, an attempt was made to optimize the flavonoid extraction using orthogonal design of experiment and subsequent structural elucidation by high-performance liquid chromatography-diode array detector-electron spray ionization/mass spectrometry (HPLC-DAD-ESI/MS) techniques. The shake flask method of flavonoid extraction was observed to provide a yield of 1.2 ± 0.13 (mg/g tissue). With the two different solvents, namely, ethanol and ethyl acetate, tried for the extraction optimization of flavonoid, ethanol (80.1 mg/g tissue) has been proved better than ethyl acetate (20.5 mg/g tissue). The optimal conditions of the extraction of flavonoid were found to be 85°C, 3 hours with a material ratio of 1 : 20, 75% ethanol, and 1 cycle of extraction. About seven different phenolics like robinin, quercetin, rutin, sinapoyl-hexoside, dicaffeic acid, and two unknown compounds were identified for the first time in the flowers of T. heyneana. The study has also concluded that L16 orthogonal design of experiment is an effective method for the extraction of flavonoid than the shake flask method. PMID:25969771

  14. Optimization of Ex Vivo Murine Bone Marrow Derived Immature Dendritic Cells: A Comparative Analysis of Flask Culture Method and Mouse CD11c Positive Selection Kit Method.

    PubMed

    Gosavi, Rahul Ashok; Salwe, Sukeshani; Mukherjee, Sandeepan; Dahake, Ritwik; Kothari, Sweta; Patel, Vainav; Chowdhary, Abhay; Deshmukh, Ranjana A

    2018-01-01

    12-14 days of culturing of bone marrow (BM) cells containing various growth factors is widely used method for generating dendritic cells (DCs) from suspended cell population. Here we compared flask culture method and commercially available CD11c Positive Selection kit method. Immature BMDCs' purity of adherent as well as suspended cell population was generated in the decreasing concentration of recombinant-murine granulocyte-macrophage colony-stimulating factor (rmGM-CSF) in nontreated tissue culture flasks. The expression of CD11c, MHCII, CD40, and CD86 was measured by flow cytometry. We found significant difference ( P < 0.05) between the two methods in the adherent cells population but no significant difference was observed between the suspended cell populations with respect to CD11c+ count. However, CD11c+ was significantly higher in both adhered and suspended cell population by culture method but kit method gave more CD11c+ from suspended cells population only. On the other hand, using both methods, immature DC expressed moderate level of MHC class II molecules as well as low levels of CD40 and CD86. Our findings suggest that widely used culture method gives the best results in terms of yield, viability, and purity of BMDCs from both adherent and suspended cell population whereas kit method works well for suspended cell population.

  15. Fabrication of viable and functional pre-vascularized modular bone tissues by coculturing MSCs and HUVECs on microcarriers in spinner flasks.

    PubMed

    Zhang, Songjie; Zhou, Min; Ye, Zhaoyang; Zhou, Yan; Tan, Wen-Song

    2017-08-01

    Slow vascularization often impedes the viability and function of engineered bone replacements. Prevascularization is a promising way to solve this problem. In this study, a new process was developed by integrating microcarrier culture and coculture to fabricate pre-vascularized bone microtissues with mesenchymal stem cells (MSCs) and human umbilical vein endothelial cells (HUVECs). Initially, coculture medium and cell ratio between MSCs and HUVECs were optimized in tissue culture plates concerning cell proliferation, osteogenesis and angiogenesis. Subsequently, cells were seeded onto CultiSpher S microcarriers in spinner flasks and subjected to a two-stage (proliferative-osteogenic) culture process for four weeks. Both cells proliferated and functioned well in chosen medium and a 1 : 1 ratio between MSCs and HUVECs was chosen for better angiogenesis. After four weeks of culture in spinner flasks, the microtissues were formed with high cellularity, evenly distributed cells and tube formation ability. While coculture with HUVECs exerted an inhibitory effect on osteogenic differentiation of MSCs, with downregulated alkaline phosphatase activity, mineralization and gene expression of COLI, RUNX2 and OCN, this could be attenuated by employing a delayed seeding strategy of HUVECs against MSCs during the microtissue fabrication process. Collectively, this work established an effective method to fabricate pre-vascularized bone microtissues, which would lay a solid foundation for subsequent development of vascularized tissue grafts for bone regeneration. Copyright © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. A proposal for a test method for assessment of hazard property HP 12 ("Release of an acute toxic gas") in hazardous waste classification - Experience from 49 waste.

    PubMed

    Hennebert, Pierre; Samaali, Ismahen; Molina, Pauline

    2016-12-01

    A stepwise method for assessment of the HP 12 is proposed and tested with 49 waste samples. The hazard property HP 12 is defined as "Release of an acute toxic gas": waste which releases acute toxic gases (Acute Tox. 1, 2 or 3) in contact with water or an acid. When a waste contains a substance assigned to one of the following supplemental hazards EUH029, EUH031 and EUH032, it shall be classified as hazardous by HP 12 according to test methods or guidelines (EC, 2014a, 2014b). When the substances with the cited hazard statement codes react with water or an acid, they can release HCl, Cl 2 , HF, HCN, PH 3 , H 2 S, SO 2 (and two other gases very unlikely to be emitted, hydrazoic acid HN 3 and selenium oxide SeO 2 - a solid with low vapor pressure). Hence, a method is proposed:For a set of 49 waste, water addition did not produce gas. Nearly all the solid waste produced a gas in contact with hydrochloric acid in 5 min in an automated calcimeter with a volume >0.1L of gas per kg of waste. Since a plateau of pressure is reached only for half of the samples in 5 min, 6 h trial with calorimetric bombs or glass flasks were done and confirmed the results. Identification of the gases by portable probes showed that most of the tested samples emit mainly CO 2 . Toxic gases are emitted by four waste: metallic dust from the aluminum industry (CO), two air pollution control residue of industrial waste incinerator (H 2 S) and a halogenated solvent (organic volatile(s) compound(s)). HF has not been measured in these trials started before the present definition of HP 12. According to the definition of HP 12, only the H 2 S emission of substances with hazard statement EUH031 is accounted for. In view of the calcium content of the two air pollution control residue, the presence of calcium sulphide (EUH031) can be assumed. These two waste are therefore classified potentially hazardous for HP 12, from a total of 49 waste. They are also classified as hazardous for other properties (HP 7, 10and14 for one of them, and HP 10and14 for the other one respectively). Given these results, it can be assumed that few common household and industrial waste will be classified hazardous only by HP 12. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Trace Gas Trends in the Stratosphere: 1991-2005

    NASA Astrophysics Data System (ADS)

    Elkins, J. W.; Moore, F. L.; Dutton, G. S.; Hurst, D. F.; Ray, E. A.; Montzka, S. A.; Butler, J. H.; Fahey, D. W.; Hall, B. H.; Atlas, E.; Wofsy, S. C.; Romashkin, P. A.

    2005-05-01

    The first NOAA airborne gas chromatograph measured chlorofluorocarbon-11 (CFC-11) and CFC-113 during the Arctic Airborne Stratospheric Experiment in 1991-1992. In 1994, we added nitrous oxide (N2O), sulfur hexafluoride (SF6), CFC-12, halon-1211, methyl chloroform, carbon tetrachloride, methane, and hydrogen. NOAA scientists have since operated five airborne gas chromatographs on NASA airborne platforms, including the NASA Jet Propulsion Laboratory (JPL) balloon gondola and ER-2, WB-57F, DC-8, and NASA Altair Unmanned Air Vehicle (UAV) aircraft. Using these in situ measurements and tracer-tracer correlations from flask observations for the unmeasured halogen species (HCFCs and methyl halides including methyl chloride and bromide), we have estimated trends of total chlorine and bromine in the stratosphere. The determination of inorganic equivalent chlorine (Cl + 45*Br) requires the trend of tropospheric equivalent chlorine and the mean age of the parcel of stratospheric air. In general, there is good agreement between the mean age of the air mass calculations using carbon dioxide and SF6, except for regions of extreme down welling of mesospheric air where SF6 is consumed. Tropospheric trends of the methyl halides have been compiled against stable standards. We operated a airborne gas chromatograph on the Sage 3 Ozone Loss Validation Experiment (SOLVE-II) mission from Kiruna, Sweden during 2002. It measured the major HCFCs and methyl halides, so that these compounds do not have to be estimated from tracer-tracer correlations in the future. In 2005, we have added a new lightweight airborne instrument (<25 kg) that can measure CFC-11, CFC-12, halon-1211, SF6, N2O, and ozone. This instrument can operate on small or UAV aircraft and will be used for Aura satellite validation. This presentation will show trends for selected trace gases and our estimates of total equivalent chlorine stratospheric trends since 1991.

  18. Decolorization of textile dyes in an air-lift bioreactor inoculated with Bjerkandera adusta OBR105.

    PubMed

    Sodaneath, Hong; Lee, Jung-In; Yang, Seung-Ok; Jung, Hyekyeng; Ryu, Hee Wook; Cho, Kyung-Suk

    2017-09-19

    A new decolorizing white-rot fungus, OBR105, was isolated from Mount Odae in South Korea and identified by the morphological characterization of its fruit body and spores and partial 18s rDNA sequences. The ligninolytic enzyme activity of OBR105 was studied to characterize their decolorizing mechanism using a spectrophotometric enzyme assay. For the evaluation of the decolorization capacity of OBR105, the isolate was incubated in an erlenmeyer flask and in an airlifte bioreator with potato dextrose broth (PDB) medium supplemented with each dye. In addition, the decolorization efficiency of real textile wastewater was evaluated in an airlift bioreactor inoculated with the isolate. The isolate was identified as Bjerkandera adusta and had ligninolytic enzymes such as laccase, lignin peroxidase (LiP), and Mn-dependent peroxidase (MnP). Its LiP activity was higher than its MnP and laccase activities. B. adusta OBR105 successfully decolorized reactive dyes (red 120, blue 4, orange 16, and black 5) and acid dyes (red 114, blue 62, orange 7, and black 172). B. adusta OBR105 decolorized 91-99% of 200 mg L -1 of each dye (except acid orange 7) within 3 days in a PDB medium at 28°C, pH 5, and 150 rpm. This fungus decolorized only 45% of 200 mg L -1 acid orange 7 (single azo-type dye) within 3 days, and the decolorization efficiency did not increase by prolonging the cultivation time. In the air-lift bioreactor, B. adusta OBR105 displayed a high decolorization capacity, greater than 90%, for 3 acid dyes (red 114, blue 62, and black 172) and 1 reactive dye (blue 4) within 10-15 h of treatment. B. adusta OBR105 could decolorize real textile wastewater in the air-lift bioreactor. This result suggests that an air-lift reactor employing B. adusta OBR105 is a promising bioreactor for the treatment of dye wastewater.

  19. Effect of photosynthesis on the abundance of 18O13C16O in atmospheric CO2

    NASA Astrophysics Data System (ADS)

    Hofmann, Magdalena E. G.; Pons, Thijs L.; Ziegler, Martin; Lourens, Lucas J.; Röckmann, Thomas

    2016-04-01

    The abundance of the isotopologue 18O13C16O (Δ47) in atmospheric air is a promising new tracer for the atmospheric carbon cycle (Eiler and Schauble, 2004; Affek and Eiler, 2006; Affek et al., 2007). The large gross fluxes in CO2 between the atmosphere and biosphere are supposed to play a major role in controlling its abundance. Eiler and Schauble (2004) set up a box model describing the effect of air-leaf interaction on the abundance of 18O13C16O in atmospheric air. The main assumption is that the exchange between CO2 and water within the mesophyll cells will imprint a Δ47 value on the back-diffusing CO2 that reflects the leaf temperature. Additionally, kinetic effects due to CO2 diffusion into and out of the stomata are thought to play a role. We investigated the effect of photosynthesis on the residual CO2 under controlled conditions using a leaf chamber set-up to quantitatively test the model assumptions suggested by Eiler and Schauble (2004). We studied the effect of photosynthesis on the residual CO2 using two C3 and one C4 plant species: (i) sunflower (Helianthus annuus), a C3 species with a high leaf conductance for CO2 diffusion, (ii) ivy (Hedera hibernica), a C3 species with a low conductance, and (iii), maize (Zea mays), a species with the C4 photosynthetic pathway. We also investigated the effect of different light intensities (photosynthetic photon flux density of 200, 700 and 1800 μmol m2s-1), and thus, photosynthetic rate in sunflower and maize. A leaf was mounted in a cuvette with a transparent window and an adjustable light source. The air inside was thoroughly mixed, making the composition of the outgoing air equal to the air inside. A gas-mixing unit was attached at the entrance of the cuvette that mixed air with a high concentration of scrambled CO2 with a Δ47 value of 0 to 0.1‰ with CO2 free air to set the CO2 concentration of ingoing air at 500 ppm. The flow rate through the cuvette was adjusted to the photosynthetic activity of the leaf so that the CO2 concentration at the outlet was 400 ppm and varied between 0.6 and 1.5 L min-1. CO2 and H2O concentrations in air were monitored with an IRGA and air was sampled at the outlet with flasks. We found that the effect on Δ47 of the residual CO2 for the C3 species sunflower and ivy was proportional to the effect on δ18O of the residual CO2. The difference in Δ47 between the in- and outgoing CO2 was between -0.07 and 0.49‰ varying with the CO2 concentration in the chloroplasts relative to the bulk air (Cc/Ca). The Cc/Ca depends on conductance and photosynthetic activity, and was different for the two species and was manipulated with the light intensity. For the C4 species maize, a Δ47 value of -0.08±0.02‰ was observed. The slightly negative effect on Δ47may be related to its lower Cc/Ca ratio and possibly a lower carbonic anhydrase activity causing incomplete exchange with leaf water. We will discuss these results in light of the suggested fractionation processes and discuss the implication for the global Δ47 value of atmospheric CO2. References Affek H. P. and Eiler J. M., GCA 70, 1-12 (2006). Affek H. P., Xu X. and Eiler J. M., GCA 71, 5033-5043 (2007). Eiler J. M. and Schauble E., GCA 68, 4767-4777 (2004).

  20. Confocal Raman Microscopy for in Situ Measurement of Octanol-Water Partitioning within the Pores of Individual C18-Functionalized Chromatographic Particles.

    PubMed

    Kitt, Jay P; Harris, Joel M

    2015-05-19

    Octanol-water partitioning is one of the most widely used predictors of hydrophobicity and lipophilicity. Traditional methods for measuring octanol-water partition coefficients (K(ow)), including shake-flasks and generator columns, require hours for equilibration and milliliter quantities of sample solution. These challenges have led to development of smaller-scale methods for measuring K(ow). Recent advances in microfluidics have produced faster and smaller-volume approaches to measuring K(ow). As flowing volumes are reduced, however, separation of water and octanol prior to measurement and detection in small volumes of octanol phase are especially challenging. In this work, we reduce the receiver volume of octanol-water partitioning measurements from current practice by six-orders-of-magnitude, to the femtoliter scale, by using a single octanol-filled reversed-phase, octadecylsilane-modified (C18-silica) chromatographic particle as a collector. The fluid-handling challenges of working in such small volumes are circumvented by eliminating postequilibration phase separation. Partitioning is measured in situ within the pore-confined octanol phase using confocal Raman microscopy, which is capable of detecting and quantifying a wide variety of molecular structures. Equilibration times are fast (less than a minute) because molecular diffusion is efficient over distance scales of micrometers. The demonstrated amount of analyte needed to carry out a measurement is very small, less than 50 fmol, which would be a useful attribute for drug screening applications or testing of small quantities of environmentally sensitive compounds. The method is tested for measurements of pH-dependent octanol-water partitioning of naphthoic acid, and the results are compared to both traditional shake-flask measurements and sorption onto C18-modified silica without octanol present within the pores.

  1. Carbon Tetrachloride Emissions from the US during 2008 - 2012 Derived from Atmospheric Data Using Bayesian and Geostatistical Inversions

    NASA Astrophysics Data System (ADS)

    Hu, L.; Montzka, S. A.; Miller, B.; Andrews, A. E.; Miller, J. B.; Lehman, S.; Sweeney, C.; Miller, S. M.; Thoning, K. W.; Siso, C.; Atlas, E. L.; Blake, D. R.; De Gouw, J. A.; Gilman, J.; Dutton, G. S.; Elkins, J. W.; Hall, B. D.; Chen, H.; Fischer, M. L.; Mountain, M. E.; Nehrkorn, T.; Biraud, S.; Tans, P. P.

    2015-12-01

    Global atmospheric observations suggest substantial ongoing emissions of carbon tetrachloride (CCl4) despite a 100% phase-out of production for dispersive uses since 1996 in developed countries and 2010 in other countries. Little progress has been made in understanding the causes of these ongoing emissions or identifying their contributing sources. In this study, we employed multiple inverse modeling techniques (i.e. Bayesian and geostatistical inversions) to assimilate CCl4 mole fractions observed from the National Oceanic and Atmospheric Administration (NOAA) flask-air sampling network over the US, and quantify its national and regional emissions during 2008 - 2012. Average national total emissions of CCl4 between 2008 and 2012 determined from these observations and an ensemble of inversions range between 2.1 and 6.1 Gg yr-1. This emission is substantially larger than the mean of 0.06 Gg/yr reported to the US EPA Toxics Release Inventory over these years, suggesting that under-reported emissions or non-reporting sources make up the bulk of CCl4 emissions from the US. But while the inventory does not account for the magnitude of observationally-derived CCl4 emissions, the regional distribution of derived and inventory emissions is similar. Furthermore, when considered relative to the distribution of uncapped landfills or population, the variability in measured mole fractions was most consistent with the distribution of industrial sources (i.e., those from the Toxics Release Inventory). Our results suggest that emissions from the US only account for a small fraction of the global on-going emissions of CCl4 (30 - 80 Gg yr-1 over this period). Finally, to ascertain the importance of the US emissions relative to the unaccounted global emission rate we considered multiple approaches to extrapolate our results to other countries and the globe.

  2. Comparison of Biomass and Lipid Production under Ambient Carbon Dioxide Vigorous Aeration and 3% Carbon Dioxide Condition Among the Lead Candidate Chlorella Strains Screened by Various Photobioreactor Scales

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kobayashi, Naoko; Barnes, Austin; Jensen, Travis

    2015-09-01

    Chlorella species from the UTEX collection, classified by rDNA-based phylogenetic analysis, were screened based on biomass and lipid production in different scales and modes of culture. Lead candidate strains of C. sorokiniana UTEX 1230 and C. vulgaris UTEX 395 and 259 were compared between conditions of vigorous aeration with filtered atmospheric air and 3% CO 2 shake-flask cultivation. We found that the biomass of UTEX 1230 produced 2 times higher at 652 mg L -1 dry weight under both ambient CO 2 vigorous aeration and 3% CO 2 conditions, while UTEX 395 and 259 under 3% CO 2 increased tomore » 3 times higher at 863 mg L -1 dry weight than ambient CO 2 vigorous aeration. The triacylglycerol contents of UTEX 395 and 259 increased more than 30 times to 30% dry weight with 3% CO 2, indicating that additional CO 2 is essential for both biomass and lipid accumulation in UTEX 395 and 259.« less

  3. Inhibition of Frying Oil Oxidation by Carbon Dioxide Blanketing.

    PubMed

    Totani, Nagao; Inoue, Ryota; Yawata, Miho

    2016-06-01

    The oxidation of oil starts, in general, from the penetration of atmospheric oxygen into oil. Inhibition of the vigorous oxidation of oil at deep-frying temperature under carbon dioxide flow, by disrupting the contact between oil and air, was first demonstrated using oil in a round bottom flask. Next, the minimum carbon dioxide flow rate necessary to blanket 4 L of frying oil in an electric fryer (surface area 690 cm(2)) installed with nonwoven fabric cover, was found to be 40 L/h. Then deep-frying of potato was done accordingly; immediately after deep-frying, an aluminum cover was placed on top of the nonwoven fabric cover to prevent the loss of carbon dioxide and the carbon dioxide flow was shut off. In conclusion, the oxidation of oil both at deep-frying temperature and during standing was remarkably inhibited by carbon dioxide blanketing at a practical flow rate and volume. Under the deep-frying conditions employed in this study, the increase in polar compound content was reduced to half of that of the control.

  4. Turbulence increases the average settling velocity of phytoplankton cells

    PubMed Central

    Ruiz, Javier; Macías, Diego; Peters, Francesc

    2004-01-01

    It is a well known fact that stirring keeps particles suspended in fluids. This is apparent, for instance, when shaking medicine flasks, when agitating tea deposits in a mug, or when heavy winds fill the air with dust particles. The commonplace nature of such observations makes it easy to accept that this feature will apply to any natural phenomenon as long as the flow is turbulent enough. This has been the case for phytoplankton in the surface mixed layers of lakes and oceans. The traditional view assumes that an increase in turbulence bears ecological advantages for nonmotile groups like diatoms that, otherwise, would settle in deep and unlit waters. However, this assumption has no theoretical ground, and the experimental results we present here point in the opposite direction. Phytoplankton settling velocity increases when turbulence intensifies from the low to the higher values recorded in the upper mixed layers of lakes and oceans. Consequently, turbulence does not favor phytoplankton remaining in lit waters but is rather an environmental stress that can only be avoided through morphological and/or physiological adaptations. PMID:15601780

  5. Metals in Metal Salts: A Copper Mirror Demonstration

    ERIC Educational Resources Information Center

    Pike, Robert D.

    2010-01-01

    A simple lecture demonstration is described to show the latent presence of metal atoms in a metal salt. Copper(II) formate tetrahydrate is heated in a round-bottom flask forming a high-quality copper mirror.

  6. 75 FR 67714 - Notice of Intent To Suspend Certain Pesticide Registrations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-03

    .... August 30, 2008.. No data received. coefficient (n- octanol/water) shake flask method. 830.7570 Partition December 14, 2007. December 24, 2007. August 30, 2008.. No data received. coefficient (n- octanol/water...

  7. Atmospheric histories and global emissions of the anthropogenic hydrofluorocarbons HFC-365mfc, HFC-245fa, HFC-227ea, and HFC-236fa

    NASA Astrophysics Data System (ADS)

    Vollmer, Martin K.; Miller, Benjamin R.; Rigby, Matthew; Reimann, Stefan; Mühle, Jens; Krummel, Paul B.; O'Doherty, Simon; Kim, Jooil; Rhee, Tae Siek; Weiss, Ray F.; Fraser, Paul J.; Simmonds, Peter G.; Salameh, Peter K.; Harth, Christina M.; Wang, Ray H. J.; Steele, L. Paul; Young, Dickon; Lunder, Chris R.; Hermansen, Ove; Ivy, Diane; Arnold, Tim; Schmidbauer, Norbert; Kim, Kyung-Ryul; Greally, Brian R.; Hill, Matthias; Leist, Michael; Wenger, Angelina; Prinn, Ronald G.

    2011-04-01

    We report on ground-based atmospheric measurements and emission estimates of the four anthropogenic hydrofluorocarbons (HFCs) HFC-365mfc (CH3CF2CH2CF3, 1,1,1,3,3-pentafluorobutane), HFC-245fa (CHF2CH2CF3, 1,1,1,3,3-pentafluoropropane), HFC-227ea (CF3CHFCF3, 1,1,1,2,3,3,3-heptafluoropropane), and HFC-236fa (CF3CH2CF3, 1,1,1,3,3,3-hexafluoropropane). In situ measurements are from the global monitoring sites of the Advanced Global Atmospheric Gases Experiment (AGAGE), the System for Observations of Halogenated Greenhouse Gases in Europe (SOGE), and Gosan (South Korea). We include the first halocarbon flask sample measurements from the Antarctic research stations King Sejong and Troll. We also present measurements of archived air samples from both hemispheres back to the 1970s. We use a two-dimensional atmospheric transport model to simulate global atmospheric abundances and to estimate global emissions. HFC-365mfc and HFC-245fa first appeared in the atmosphere only ˜1 decade ago; they have grown rapidly to globally averaged dry air mole fractions of 0.53 ppt (in parts per trillion, 10-12) and 1.1 ppt, respectively, by the end of 2010. In contrast, HFC-227ea first appeared in the global atmosphere in the 1980s and has since grown to ˜0.58 ppt. We report the first measurements of HFC-236fa in the atmosphere. This long-lived compound was present in the atmosphere at only 0.074 ppt in 2010. All four substances exhibit yearly growth rates of >8% yr-1 at the end of 2010. We find rapidly increasing emissions for the foam-blowing compounds HFC-365mfc and HFC-245fa starting in ˜2002. After peaking in 2006 (HFC-365mfc: 3.2 kt yr-1, HFC-245fa: 6.5 kt yr-1), emissions began to decline. Our results for these two compounds suggest that recent estimates from long-term projections (to the late 21st century) have strongly overestimated emissions for the early years of the projections (˜2005-2010). Global HFC-227ea and HFC-236fa emissions have grown to average values of 2.4 kt yr-1 and 0.18 kt yr-1 over the 2008-2010 period, respectively.

  8. Microbiological contamination of compressed air used in dentistry: an investigation.

    PubMed

    Conte, M; Lynch, R M; Robson, M G

    2001-11-01

    The purpose of this preliminary investigation was twofold: 1) to examine the possibility of cross-contamination between a dental-evacuation system and the compressed air used in dental operatories and 2) to capture and identify the most common microflora in the compressed-air supply. The investigation used swab, water, and air sampling that was designed to track microorganisms from the evacuation system, through the air of the mechanical room, into the compressed-air system, and back to the patient. Samples taken in the vacuum system, the air space in the mechanical room, and the compressed-air storage tank had significantly higher total concentrations of bacteria than the outside air sampled. Samples of the compressed air returning to the operatory were found to match the outside air sample in total bacteria. It was concluded that the air dryer may have played a significant role in the elimination of microorganisms from the dental compressed-air supply.

  9. Environmental Impact of the Helen, Research, and Chicago Mercury Mines on Water, Sediment, and Biota in the Upper Dry Creek Watershed, Lake County, California

    USGS Publications Warehouse

    Rytuba, James J.; Hothem, Roger L.; May, Jason T.; Kim, Christopher S.; Lawler, David; Goldstein, Daniel; Brussee, Brianne E.

    2009-01-01

    The Helen, Research, and Chicago mercury (Hg) deposits are among the youngest Hg deposits in the Coast Range Hg mineral belt and are located in the southwestern part of the Clear Lake volcanic field in Lake County, California. The mine workings and tailings are located in the headwaters of Dry Creek. The Helen Hg mine is the largest mine in the watershed having produced about 7,600 flasks of Hg. The Chicago and Research Hg mines produced only a small amount of Hg, less than 30 flasks. Waste rock and tailings have eroded from the mines, and mine drainage from the Helen and Research mines contributes Hg-enriched mine wastes to the headwaters of Dry Creek and contaminate the creek further downstream. The mines are located on federal land managed by the U.S. Bureau of Land Management (USBLM). The USBLM requested that the U.S. Geological Survey (USGS) measure and characterize Hg and geochemical constituents in tailings, sediment, water, and biota at the Helen, Research, and Chicago mines and in Dry Creek. This report is made in response to the USBLM request to conduct a Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA - Removal Site Investigation (RSI). The RSI applies to removal of Hg-contaminated mine waste from the Helen, Research, and Chicago mines as a means of reducing Hg transport to Dry Creek. This report summarizes data obtained from field sampling of mine tailings, waste rock, sediment, and water at the Helen, Research, and Chicago mines on April 19, 2001, during a storm event. Further sampling of water, sediment, and biota at the Helen mine area and the upper part of Dry Creek was completed on July 15, 2003, during low-flow conditions. Our results permit a preliminary assessment of the mining sources of Hg and associated chemical constituents that could elevate levels of monomethyl Hg (MMeHg) in the water, sediment, and biota that are impacted by historic mining.

  10. M-FISH Analysis of Chromosome Aberrations in Human Fibroblast Cells After In Vitro Exposure to Low- and High-LET Radiation

    NASA Technical Reports Server (NTRS)

    Wu, Honglu; Furusawa, Yoshiya; George, Kerry; Kawata, Tetsuya; Cucinotta, Francis

    2002-01-01

    The recently commercialized multiplex fluorescence in situ hybridization (m-FISH) technique, which allows human chromosomes to be painted in 24 different colors, was used to analyze chromosome aberrations in diploid human fibroblast cells after in vitro radiation exposure. Confluent flasks of a normal primary fibroblast cell line (AG 1522) were irradiated at high dose rates with either gamma rays or 200 MeV/nucleon Fe ions (LET = 440 keV/micron), incubated at 37 C for 24 hours after exposure, and subsequently subcultured. A chemically induced premature chromosome condensation technique was used to collect chromosome samples 32 hours after subculture. Results showed that the fraction of exchanges which were identified as complex, i.e. involving misrejoining of three or more DSB, were higher in the Fe-irradiated samples compared with the gamma-irradiated samples, as has been shown previously using FISH with one or two painted chromosomes . The ratios of complex/simple type exchanges were similar for samples irradiated with 0.7 Gy and 3 Gy of Fe ions, although exchanges involving five or more breaks were found only in 3 Gy irradiated samples. The fraction of incomplete exchanges was also higher in Fe- than gamma-irradiated samples. Data on the distribution of individual chromosome involvement in interchromosomal exchanges will be presented.

  11. Diagnosing AIRS Sampling with CloudSat Cloud Classes

    NASA Technical Reports Server (NTRS)

    Fetzer, Eric; Yue, Qing; Guillaume, Alexandre; Kahn, Brian

    2011-01-01

    AIRS yield and sampling vary with cloud state. Careful utilization of collocated multiple satellite sensors is necessary. Profile differences between AIRS and ECMWF model analyses indicate that AIRS has high sampling and excellent accuracy for certain meteorological conditions. Cloud-dependent sampling biases may have large impact on AIRS L2 and L3 data in climate research. MBL clouds / lower tropospheric stability relationship is one example. AIRS and CloudSat reveal a reasonable climatology in the MBL cloud regime despite limited sampling in stratocumulus. Thermodynamic parameters such as EIS derived from AIRS data map these cloud conditions successfully. We are working on characterizing AIRS scenes with mixed cloud types.

  12. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study.

    PubMed

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D'Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-06-22

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis ® μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis ® μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis ® μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis ® μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations.

  13. Evaluation of Legionella Air Contamination in Healthcare Facilities by Different Sampling Methods: An Italian Multicenter Study

    PubMed Central

    Montagna, Maria Teresa; De Giglio, Osvalda; Cristina, Maria Luisa; Napoli, Christian; Pacifico, Claudia; Agodi, Antonella; Baldovin, Tatjana; Casini, Beatrice; Coniglio, Maria Anna; D’Errico, Marcello Mario; Delia, Santi Antonino; Deriu, Maria Grazia; Guida, Marco; Laganà, Pasqualina; Liguori, Giorgio; Moro, Matteo; Mura, Ida; Pennino, Francesca; Privitera, Gaetano; Romano Spica, Vincenzo; Sembeni, Silvia; Spagnolo, Anna Maria; Tardivo, Stefano; Torre, Ida; Valeriani, Federica; Albertini, Roberto; Pasquarella, Cesira

    2017-01-01

    Healthcare facilities (HF) represent an at-risk environment for legionellosis transmission occurring after inhalation of contaminated aerosols. In general, the control of water is preferred to that of air because, to date, there are no standardized sampling protocols. Legionella air contamination was investigated in the bathrooms of 11 HF by active sampling (Surface Air System and Coriolis®μ) and passive sampling using settling plates. During the 8-hour sampling, hot tap water was sampled three times. All air samples were evaluated using culture-based methods, whereas liquid samples collected using the Coriolis®μ were also analyzed by real-time PCR. Legionella presence in the air and water was then compared by sequence-based typing (SBT) methods. Air contamination was found in four HF (36.4%) by at least one of the culturable methods. The culturable investigation by Coriolis®μ did not yield Legionella in any enrolled HF. However, molecular investigation using Coriolis®μ resulted in eight HF testing positive for Legionella in the air. Comparison of Legionella air and water contamination indicated that Legionella water concentration could be predictive of its presence in the air. Furthermore, a molecular study of 12 L. pneumophila strains confirmed a match between the Legionella strains from air and water samples by SBT for three out of four HF that tested positive for Legionella by at least one of the culturable methods. Overall, our study shows that Legionella air detection cannot replace water sampling because the absence of microorganisms from the air does not necessarily represent their absence from water; nevertheless, air sampling may provide useful information for risk assessment. The liquid impingement technique appears to have the greatest capacity for collecting airborne Legionella if combined with molecular investigations. PMID:28640202

  14. Biobriefcase aerosol collector

    DOEpatents

    Bell, Perry M [Tracy, CA; Christian, Allen T [Madison, WI; Bailey, Christopher G [Pleasanton, CA; Willis, Ladona [Manteca, CA; Masquelier, Donald A [Tracy, CA; Nasarabadi, Shanavaz L [Livermore, CA

    2009-09-22

    A system for sampling air and collecting particles entrained in the air that potentially include bioagents. The system comprises providing a receiving surface, directing a liquid to the receiving surface and producing a liquid surface. Collecting samples of the air and directing the samples of air so that the samples of air with particles entrained in the air impact the liquid surface. The particles potentially including bioagents become captured in the liquid. The air with particles entrained in the air impacts the liquid surface with sufficient velocity to entrain the particles into the liquid but cause minor turbulence. The liquid surface has a surface tension and the collector samples the air and directs the air to the liquid surface so that the air with particles entrained in the air impacts the liquid surface with sufficient velocity to entrain the particles into the liquid, but cause minor turbulence on the surface resulting in insignificant evaporation of the liquid.

  15. Development and testing of a portable wind sensitive directional air sampler

    NASA Technical Reports Server (NTRS)

    Deyo, J.; Toma, J.; King, R. B.

    1975-01-01

    A portable wind sensitive directional air sampler was developed as part of an air pollution source identification system. The system is designed to identify sources of air pollution based on the directional collection of field air samples and their analysis for TSP and trace element characteristics. Sources can be identified by analyzing the data on the basis of pattern recognition concepts. The unit, designated Air Scout, receives wind direction signals from an associated wind vane. Air samples are collected on filter slides using a standard high volume air sampler drawing air through a porting arrangement which tracks the wind direction and permits collection of discrete samples. A preset timer controls the length of time each filter is in the sampling position. At the conclusion of the sampling period a new filter is automatically moved into sampling position displacing the previous filter to a storage compartment. Thus the Air Scout may be set up at a field location, loaded with up to 12 filter slides, and left to acquire air samples automatically, according to the wind, at any timer interval desired from 1 to 30 hours.

  16. A method for the solvent extraction of low-boiling-point plant volatiles.

    PubMed

    Xu, Ning; Gruber, Margaret; Westcott, Neil; Soroka, Julie; Parkin, Isobel; Hegedus, Dwayne

    2005-01-01

    A new method has been developed for the extraction of volatiles from plant materials and tested on seedling tissue and mature leaves of Arabidopsis thaliana, pine needles and commercial mixtures of plant volatiles. Volatiles were extracted with n-pentane and then subjected to quick distillation at a moderate temperature. Under these conditions, compounds such as pigments, waxes and non-volatile compounds remained undistilled, while short-chain volatile compounds were distilled into a receiving flask using a high-efficiency condenser. Removal of the n-pentane and concentration of the volatiles in the receiving flask was carried out using a Vigreux column condenser prior to GC-MS. The method is ideal for the rapid extraction of low-boiling-point volatiles from small amounts of plant material, such as is required when conducting metabolic profiling or defining biological properties of volatile components from large numbers of mutant lines.

  17. Dynamic cell culture on porous biopolymer microcarriers in a spinner flask for bone tissue engineering: a feasibility study.

    PubMed

    Jin, Guang-Zhen; Park, Jeong-Hui; Seo, Seog-Jin; Kim, Hae-Won

    2014-07-01

    Porous microspherical carriers have great promise for cell culture and tissue engineering. Dynamic cultures enable more uniform cell population and effective differentiation than static cultures. Here we applied dynamic spinner flask culture for the loading and multiplication of cells onto porous biopolymer microcarriers. The abilities of the microcarriers to populate cells and to induce osteogenic differentiation were examined and the feasibility of in vivo delivery of the constructs was addressed. Over time, the porous microcarriers enabled cell adhesion and expansion under proper dynamic culture conditions. Osteogenic markers were substantially expressed by the dynamic cell cultures. The cell-cultured microcarriers implanted in the mouse subcutaneous tissue for 4 weeks showed excellent tissue compatibility, with minimal inflammatory signs and significant induction of bone tissues. This first report on dynamic culture of porous biopolymer microcarriers providing an effective tool for bone tissue engineering.

  18. Effective ethanol production from whey powder through immobilized E. coli expressing Vitreoscilla hemoglobin.

    PubMed

    Sar, Taner; Stark, Benjamin C; Yesilcimen Akbas, Meltem

    2017-03-04

    Ethanol production from whey powder was investigated by using free as well as alginate immobilized E. coli and E. coli expressing Vitreoscilla hemoglobin (VHb) in both shake flask and fermenter cultures. Media with varying levels of whey (lactose contents of 3%, 5%, 8% or 15%) and yeast extract (0.3% or 0.5%) were evaluated with fermentation times of 48-96 h. Immobilization and VHb expression resulted in higher ethanol production with all media; the increases ranged from 2% to 89% for immobilization and from 2% to 182% for VHb expression. It was determined that growth medium containing 8% lactose with 0.5% yeast extract yielded the highest ethanol production for free or immobilized strains, with or without VHb expression, in both shake flask and fermenter cultures. Immobilization with alginate was found to be a promising process for ethanol production by VHb-expressing ethanologenic E. coli.

  19. Effective ethanol production from whey powder through immobilized E. coli expressing Vitreoscilla hemoglobin

    PubMed Central

    Sar, Taner; Stark, Benjamin C.; Yesilcimen Akbas, Meltem

    2017-01-01

    ABSTRACT Ethanol production from whey powder was investigated by using free as well as alginate immobilized E. coli and E. coli expressing Vitreoscilla hemoglobin (VHb) in both shake flask and fermenter cultures. Media with varying levels of whey (lactose contents of 3%, 5%, 8% or 15%) and yeast extract (0.3% or 0.5%) were evaluated with fermentation times of 48–96 h. Immobilization and VHb expression resulted in higher ethanol production with all media; the increases ranged from 2% to 89% for immobilization and from 2% to 182% for VHb expression. It was determined that growth medium containing 8% lactose with 0.5% yeast extract yielded the highest ethanol production for free or immobilized strains, with or without VHb expression, in both shake flask and fermenter cultures. Immobilization with alginate was found to be a promising process for ethanol production by VHb-expressing ethanologenic E. coli. PMID:27579556

  20. Automatic dispensing of liquid nitrogen in submilliliter doses

    NASA Astrophysics Data System (ADS)

    Milner, C. J.

    1984-10-01

    Well-controlled doses of 0.2 to 0.5 ml of liquid nitrogen are delivered, on electrical signal (not more than once per 5 s), as fills of a miniature bucket raised by an automatic hoist. The bucket is lifted, brimming, from the storage flask and then moved sideways until over the receiver. At this point, a steel ball, which has been resting in and sealing a drain hole in the bucket, is lifted from its seat by a magnet fixed alongside the (now descending) bucket. Design features are outlined: some alternative designs, valving liquid through a short drain tube fixed in the storage flask, are briefly reviewed. In tests the device delivered 74 g (approx. 260 doses) during 63 min, the loss by evaporation meanwhile being 11 g from the bucket, implying a transfer efficiency of 87%. An indirect measure indicated the dose sizes as 354±10 μl approximately.

  1. Comparative biodegradation of HDPE and LDPE using an indigenously developed microbial consortium.

    PubMed

    Satlewal, Alok; Soni, Ravindra; Zaidi, Mgh; Shouche, Yogesh; Goel, Reeta

    2008-03-01

    A variety of bacterial strains were isolated from waste disposal sites of Uttaranchal, India, and some from artificially developed soil beds containing maleic anhydride, glucose, and small pieces of polyethylene. Primary screening of isolates was done based on their ability to utilize high- and low-density polyethylenes (HDPE/LDPE) as a primary carbon source. Thereafter, a consortium was developed using potential strains. Furthermore, a biodegradation assay was carried out in 500-ml flasks containing minimal broth (250 ml) and HDPE/ LDPE at 5 mg/ml concentration. After incubation for two weeks, degraded samples were recovered through filtration and subsequent evaporation. Fourier transform infrared spectroscopy (FTIR) and simultaneous thermogravimetric-differential thermogravimetry-differential thermal analysis TG-DTG-DTA) were used to analyze these samples. Results showed that consortium-treated HDPE (considered to be more inert relative to LDPE) was degraded to a greater extent 22.41% weight loss) in comparison with LDPE (21.70% weight loss), whereas, in the case of untreated samples, weight loss was more for LDPE than HDPE (4.5% and 2.5%, respectively) at 400 degrees . Therefore, this study suggests that polyethylene could be degraded by utilizing microbial consortia in an eco-friendly manner.

  2. Atmospheric O2, CO2 and delta13C measurements from aircraft sampling over Griffin Forest, Perthshire, UK.

    PubMed

    Sturm, Patrick; Leuenberger, Markus; Moncrieff, John; Ramonet, Michel

    2005-01-01

    Regular vertical aircraft sampling has been performed in the lower troposphere above Griffin Forest, near Aberfeldy, Perthshire, UK (56 degrees 37'N, 3 degrees 47'W), between February 2003 and May 2004, for analysis of O2/N2, CO2 and delta13C of CO2. We sampled flasks between 800 and 3100 m above sea level. The peak-to-peak amplitude of the seasonal cycle of O2/N2 decreases from 171 per meg at 800 m to 113 per meg at 3100 m. Furthermore, the seasonal cycle is shifted from low to high altitudes with a lag of about 1 month. The same features are observed for CO2 with a decrease in the peak-to-peak amplitude of the seasonal cycle from 17.6 ppm at 800 m to 11.4 ppm at 3100 m. The vertical profiles show decreasing O2/N2 ratios in summer and increasing O2/N2 ratios in wintertime with increasing sampling height, due to surface exchange of oxygen with the land biosphere and the ocean. The O2:CO2 exchange ratios of the vertical profiles vary between -1.5 and -2.4 mol O2/mol CO2. Copyright (c) 2005 John Wiley & Sons, Ltd.

  3. Adaptive Sampling for Urban Air Quality through Participatory Sensing

    PubMed Central

    Zeng, Yuanyuan; Xiang, Kai

    2017-01-01

    Air pollution is one of the major problems of the modern world. The popularization and powerful functions of smartphone applications enable people to participate in urban sensing to better know about the air problems surrounding them. Data sampling is one of the most important problems that affect the sensing performance. In this paper, we propose an Adaptive Sampling Scheme for Urban Air Quality (AS-air) through participatory sensing. Firstly, we propose to find the pattern rules of air quality according to the historical data contributed by participants based on Apriori algorithm. Based on it, we predict the on-line air quality and use it to accelerate the learning process to choose and adapt the sampling parameter based on Q-learning. The evaluation results show that AS-air provides an energy-efficient sampling strategy, which is adaptive toward the varied outside air environment with good sampling efficiency. PMID:29099766

  4. Single-Pass, Closed-System Rapid Expansion of Lymphocyte Cultures for Adoptive Cell Therapy

    PubMed Central

    Klapper, Jacob A.; Thomasian, Armen A.; Smith, Douglas M.; Gorgas, Gayle C.; Wunderlich, John R.; Smith, Franz O.; Hampson, Brian S.; Rosenberg, Steven A.; Dudley, Mark E.

    2009-01-01

    Adoptive cell therapy (ACT) for metastatic melanoma involves the ex vivo expansion and re-infusion of tumor infiltrating lymphocytes (TIL) obtained from resected specimens. With an overall objective response rate of fifty-six percent, this T-cell immunotherapy provides an appealing alternative to other therapies, including conventional therapies with lower response rates. However, there are significant regulatory and logistical concerns associated with the ex vivo activation and large scale expansion of these cells. The best current practice uses a rapid expansion protocol (REP) consisting of an ex vivo process that occurs in tissue culture flasks (T-flasks) and gas-permeable bags, utilizes OKT3 (anti-CD3 monoclonal antibody), recombinant human interleukin-2, and irradiated peripheral blood mononuclear cells to initiate rapid lymphocyte growth. A major limitation to the widespread delivery of therapy to large numbers of melanoma patients is the open system in which a REP is initiated. To address this problem, we have investigated the initiation, expansion and harvest at clinical scale of TIL in a closed-system continuous perfusion bioreactor. Each cell product met all safety criteria for patient treatment and by head-to-head comparison had a similar potency and phenotype as cells grown in control T-flasks and gas-permeable bags. However, the currently available bioreactor cassettes were limited in the total cell numbers that could be generated. This bioreactor may simplify the process of the rapid expansion of TIL under stringent regulatory conditions thereby enabling other institutions to pursue this form of ACT. PMID:19389403

  5. In vitro cartilage construct generation from silk fibroin- chitosan porous scaffold and umbilical cord blood derived human mesenchymal stem cells in dynamic culture condition.

    PubMed

    Agrawal, Parinita; Pramanik, Krishna; Biswas, Amit; Ku Patra, Ranjan

    2018-02-01

    Cartilage construct generation includes a scaffold with appropriate composition to mimic matrix of the damaged tissue on which the stem cells grow and differentiate. In this study, umbilical cord blood (UCB) derived human mesenchymal stem cells (hMSCs) were seeded on freeze dried porous silk-fibroin (SF)/chitosan (CS) scaffolds. Influence of static and dynamic (spinner flask bioreactor) culture conditions on the developing cartilage construct were studied by in-vitro characterization for viability, proliferation, distribution, and chondrogenic differentiation of hMSCs over the scaffold. Constructs developed in spinner flask consisted of 62% live cells, and exhibited 543% more cell density at the core than constructs cultured in static system. Quantification of DNA and glycosaminoglycans accumulation after 21 days showed the progression of chondrogenic differentiation of hMSCs was higher in dynamic culture compared to static one. In constructs generated under dynamic condition, histology staining for proteoglycan matrix, and fluorescence staining for collagen-II and aggrecan showed positive correlation between early and late stage chondrogenic markers, which was further confirmed by quantitative PCR analysis, showing low collagen-I expression and highly expressed Sox9, collagen-II and aggrecan. The present study demonstrated that construct generated by combining 3D SF/CS scaffold with UCB-hMSCs under dynamic condition using spinner flask bioreactor can be used for cartilage tissue regeneration for future medical treatments. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 397-407, 2018. © 2017 Wiley Periodicals, Inc.

  6. Unique differentiation profile of mouse embryonic stem cells in rotary and stirred tank bioreactors.

    PubMed

    Fridley, Krista M; Fernandez, Irina; Li, Mon-Tzu Alice; Kettlewell, Robert B; Roy, Krishnendu

    2010-11-01

    Embryonic stem (ES)-cell-derived lineage-specific stem cells, for example, hematopoietic stem cells, could provide a potentially unlimited source for transplantable cells, especially for cell-based therapies. However, reproducible methods must be developed to maximize and scale-up ES cell differentiation to produce clinically relevant numbers of therapeutic cells. Bioreactor-based dynamic culture conditions are amenable to large-scale cell production, but few studies have evaluated how various bioreactor types and culture parameters influence ES cell differentiation, especially hematopoiesis. Our results indicate that cell seeding density and bioreactor speed significantly affect embryoid body formation and subsequent generation of hematopoietic stem and progenitor cells in both stirred tank (spinner flask) and rotary microgravity (Synthecon™) type bioreactors. In general, high percentages of hematopoietic stem and progenitor cells were generated in both bioreactors, especially at high cell densities. In addition, Synthecon bioreactors produced more sca-1(+) progenitors and spinner flasks generated more c-Kit(+) progenitors, demonstrating their unique differentiation profiles. cDNA microarray analysis of genes involved in pluripotency, germ layer formation, and hematopoietic differentiation showed that on day 7 of differentiation, embryoid bodies from both bioreactors consisted of all three germ layers of embryonic development. However, unique gene expression profiles were observed in the two bioreactors; for example, expression of specific hematopoietic genes were significantly more upregulated in the Synthecon cultures than in spinner flasks. We conclude that bioreactor type and culture parameters can be used to control ES cell differentiation, enhance unique progenitor cell populations, and provide means for large-scale production of transplantable therapeutic cells.

  7. Large-scale progenitor cell expansion for multiple donors in a monitored hollow fibre bioreactor.

    PubMed

    Lambrechts, Toon; Papantoniou, Ioannis; Rice, Brent; Schrooten, Jan; Luyten, Frank P; Aerts, Jean-Marie

    2016-09-01

    With the increasing scale in stem cell production, a robust and controlled cell expansion process becomes essential for the clinical application of cell-based therapies. The objective of this work was the assessment of a hollow fiber bioreactor (Quantum Cell Expansion System from Terumo BCT) as a cell production unit for the clinical-scale production of human periosteum derived stem cells (hPDCs). We aimed to demonstrate comparability of bioreactor production to standard culture flask production based on a product characterization in line with the International Society of Cell Therapy in vitro benchmarks and supplemented with a compelling quantitative in vivo bone-forming potency assay. Multiple process read-outs were implemented to track process performance and deal with donor-to-donor-related variation in nutrient needs and harvest timing. The data show that the hollow fiber bioreactor is capable of robustly expanding autologous hPDCs on a clinical scale (yield between 316 million and 444 million cells starting from 20 million after ± 8 days of culture) while maintaining their in vitro quality attributes compared with the standard flask-based culture. The in vivo bone-forming assay on average resulted in 10.3 ± 3.7% and 11.0 ± 3.8% newly formed bone for the bioreactor and standard culture flask respectively. The analysis showed that the Quantum system provides a reproducible cell expansion process in terms of yields and culture conditions for multiple donors. Copyright © 2016 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  8. Trichloroethylene biodegradation by mesophilic and psychrophilic ammonia oxidizers and methanotrophs in groundwater microcosms.

    PubMed Central

    Moran, B N; Hickey, W J

    1997-01-01

    This study investigated the efficiency of methane and ammonium for stimulating trichloroethylene (TCE) biodegradation in groundwater microcosms (flasks and batch exchange columns) at a psychrophilic temperature (12 degrees C) typical of shallow aquifers in the northern United States or a mesophilic temperature (24 degrees C) representative of most laboratory experiments. After 140 days, TCE biodegradation rates by ammonia oxidizers and methanotrophs in mesophilic flask microcosms were similar (8 to 10 nmol day-1), but [14C]TCE mineralization (biodegradation to 14CO2) by ammonia oxidizers was significantly greater than that by methanotrophs (63 versus 53%). Under psychrophilic conditions, [14C]TCE mineralization in flask systems by ammonia oxidizers and methanotrophs was reduced to 12 and 5%, respectively. In mesophilic batch exchange columns, average TCE biodegradation rates for methanotrophs (900 nmol liter-1 day-1) were not significantly different from those of ammonia oxidizers (775 nmol liter-1 day-1). Psychrophilic TCE biodegradation rates in the columns were similar with both biostimulants and averaged 145 nmol liter-1 day-1. Methanotroph biostimulation was most adversely affected by low temperatures. At 12 degrees C, the biodegradation efficiencies (TCE degradation normalized to microbial activity) of methanotrophs and ammonia oxidizers decreased by factors of 2.6 and 1.6, respectively, relative to their biodegradation efficiencies at 24 degrees C. Collectively, these experiments demonstrated that in situ bioremediation of TCE is feasible at the psychrophilic temperatures common in surficial aquifers in the northern United States and that for such applications biostimulation of ammonia oxidizers could be more effective than has been previously reported. PMID:9327550

  9. Development of a method for efficient cost-effective screening of Aspergillus niger mutants having increased production of glucoamylase.

    PubMed

    Zhu, Xudong; Arman, Bessembayev; Chu, Ju; Wang, Yonghong; Zhuang, Yingping

    2017-05-01

    To develop an efficient cost-effective screening process to improve production of glucoamylase in Aspergillus niger. The cultivation of A. niger was achieved with well-dispersed morphology in 48-deep-well microtiter plates, which increased the throughput of the samples compared to traditional flask cultivation. There was a close negative correlation between glucoamylase and its pH of the fermentation broth. A novel high-throughput analysis method using Methyl Orange was developed. When compared to the conventional analysis method using 4-nitrophenyl α-D-glucopyranoside as substrate, a correlation coefficient of 0.96 by statistical analysis was obtained. Using this novel screening method, we acquired a strain with an activity of 2.2 × 10 3  U ml -1 , a 70% higher yield of glucoamylase than its parent strain.

  10. Apparatus for Teaching Physics.

    ERIC Educational Resources Information Center

    Mamola, Karl C., Ed.

    1993-01-01

    Discusses how to build an inexpensive Young's modulus apparatus and also a lens with an adjustable focal length. Describes the demonstration of moving a peeled, hard-boiled egg in and out of a flask whose neck is slightly smaller than the egg. (MVL)

  11. 40 CFR 799.6755 - TSCA partition coefficient (n-octanol/water), shake flask method.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... fact that the P becomes dependent upon the concentration of the solution. Because of the multiple... Potential of Organic Chemicals in Fish. Environmental Science and Technology 8:1113 (1974). (2) Leo, A. et...

  12. 21 CFR 178.3910 - Surface lubricants used in the manufacture of metallic articles.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 10 minutes. (The reaction between the sulfoxide and the acid is exothermic. Release pressure after...,” above) until siphon action occurs and then refill the tube body. Supply heat to the boiling flask and...

  13. Increasing L-threonine production in Escherichia coli by engineering the glyoxylate shunt and the L-threonine biosynthesis pathway.

    PubMed

    Zhao, Hui; Fang, Yu; Wang, Xiaoyuan; Zhao, Lei; Wang, Jianli; Li, Ye

    2018-04-30

    L-threonine is an important amino acid that can be added in food, medicine, or feed. Here, the influence of glyoxylate shunt on an L-threonine producing strain Escherichia coli TWF001 has been studied. The gene iclR was deleted, and the native promoter of the aceBA operon was replaced by the trc promoter in the chromosome of TWF001, the resulting strainTWF004 could produce 0.39 g L-threonine from1 g glucose after 36-h flask cultivation. Further replacing the native promoter of aspC by the trc promoter in the chromosome of TWF004 resulted in the strain TWF006. TWF006 could produce 0.42 g L-threonine from 1 g glucose after 36-h flask cultivation. Three key genes in the biosynthetic pathway of L-threonine, thrA * (a mutated thrA), thrB, and thrC were overexpressed in TWF006, resulting the strain TWF006/pFW01-thrA * BC. TWF006/pFW01-thrA * BC could produce 0.49 g L-threonine from 1 g glucose after 36-h flask cultivation. Next, the genes asd, rhtA, rhtC, or thrE were inserted into the plasmid TWF006/pFW01-thrA * BC, and TWF006 was transformed with these plasmids, resulting the strains TWF006/pFW01-thrA * BC-asd, TWF006/pFW01-thrA * BC-rhtA, TWF006/pFW01-thrA * BC-rhtC, and TWF006/pFW01-thrA * BC-thrE, respectively. These four strains could produce more L-threonine than the control strain, and the highest yield was produced by TWF006/pFW01-thrA * BC-asd; after 36-h flask cultivation, TWF006/pFW01-thrA * BC-asd could produce 15.85 g/l L-threonine, i.e., 0.53 g L-threonine per 1 g glucose, which is a 70% increase relative to the control strain TWF001. The results suggested that the combined engineering of glyoxylate shunt and L-threonine biosynthesis pathway could significantly increase the L-threonine production in E. coli.

  14. Simulation of Local Seismic Ground Motions from the FLASK Underground Nuclear Explosion near the Source Physics Experiment Dry Alluvium Geology Site

    NASA Astrophysics Data System (ADS)

    Rodgers, A. J.; Pitarka, A.; Wagoner, J. L.; Helmberger, D. V.

    2017-12-01

    The FLASK underground nuclear explosion (UNE) was conducted in Area 2 of Yucca Flat at the Nevada Test Site on May 26, 1970. The yield was 105 kilotons (DOE/NV-209-Rev 16) and the working point was 529 m below the surface. This test was detonated in faulted Tertiary volcanic rocks of Yucca Flat. Coincidently, the FLASK UNE ground zero (GZ) is close (< 600 m) to the U2ez hole where the Source Physics Experiment will be conducting Phase II of its chemical high explosives test series in the so-called Dry Alluvium Geology (DAG) site. Ground motions from FLASK were recorded by twelve (12) three-component seismic stations in the near-field at ranges 3-4 km. We digitized the paper records and used available metadata on peak particle velocity measurements made at the time to adjust the amplitudes. These waveforms show great variability in amplitudes and waveform complexity with azimuth from the shot, likely due to along propagation path structure such as the geometry of the hard-rock/alluvium contact above the working point. Peak particle velocities at stations in the deeper alluvium to the north, east and south of GZ have larger amplitudes than those to the west where the basement rock is much shallower. Interestingly, the transverse components show a similar trend with azimuth. In fact, the transverse component amplitudes are similar to the other components for many stations overlying deeper basement. In this study, we simulated the seismic response at the available near-field stations using the SW4 three-dimensional (3D) finite difference code. SW4 can simulate seismic wave propagation in 3D inelastic earth structure, including surface topography. SW4 includes vertical mesh refinement which greatly reduces the computational resources needed to run a specific problem. Simulations are performed on high-performance computers with grid spacing as small as 10 meters and resolution to 6 Hz. We are testing various subsurface models to identify the role of 3D structure on path propagation effects from the source. We are also testing 3D models to constrain structure for the upcoming DAG experiments in 2018.

  15. Eight Year Climatologies from Observational (AIRS) and Model (MERRA) Data

    NASA Technical Reports Server (NTRS)

    Hearty, Thomas; Savtchenko, Andrey; Won, Young-In; Theobalk, Mike; Vollmer, Bruce; Manning, Evan; Smith, Peter; Ostrenga, Dana; Leptoukh, Greg

    2010-01-01

    We examine climatologies derived from eight years of temperature, water vapor, cloud, and trace gas observations made by the Atmospheric Infrared Sounder (AIRS) instrument flying on the Aqua satellite and compare them to similar climatologies constructed with data from a global assimilation model, the Modern Era Retrospective-Analysis for Research and Applications (MERRA). We use the AIRS climatologies to examine anomalies and trends in the AIRS data record. Since sampling can be an issue for infrared satellites in low earth orbit, we also use the MERRA data to examine the AIRS sampling biases. By sampling the MERRA data at the AIRS space-time locations both with and without the AIRS quality control we estimate the sampling bias of the AIRS climatology and the atmospheric conditions where AIRS has a lower sampling rate. While the AIRS temperature and water vapor sampling biases are small at low latitudes, they can be more than a few degrees in temperature or 10 percent in water vapor at higher latitudes. The largest sampling biases are over desert. The AIRS and MERRA data are available from the Goddard Earth Sciences Data and Information Services Center (GES DISC). The AIRS climatologies we used are available for analysis with the GIOVANNI data exploration tool. (see, http://disc.gsfc.nasa.gov).

  16. Glyphosate Dissipation in Different Soils Under No-Till and Conventional Till

    NASA Astrophysics Data System (ADS)

    Okada, Elena; Costa, Jose Luis; Francisco, Bedmar

    2017-04-01

    Glyphosate is the most used herbicide in Argentina, accounting for 62% of the commercialized pesticides in the market. It is used as a weed controller in chemical fallow under no-till systems, and it is also applied in various genetically modified crops (e.g. soybean, corn, cotton). Though it has a high solubility in water, it tends to adsorb and accumulate in agricultural soils. The description of glyphosate biodegradation in soils with a long term history under agricultural practices is of interest. The main objectives of this work were to compare the dissipation of glyphosate and the accumulation of its metabolite aminomethylphosphonic acid (AMPA) over time in three soils from Argentina. The studied soils belong to areas of high agronomic land use and different edaphoclimatic conditions, situated in Manfredi (MAN), Pergamino (PER) and Paraná (PAR). Soil samples were taken from long-term field trials with a history of more than 16 years under no-till and conventional tillage management. To study glyphosate dissipation in soil under controlled laboratory conditions, 400 g of dry soil sample were placed in 1.5 L flasks. A dose corresponding to 6 L ha-1 of commercial glyphosate ATANOR II® (35.6 % a.i.) was applied on day 0. The dose applied was equivalent to a final concentration in soil of 4000 μg Kg-1 of active ingredient. The moisture of the soil samples was kept at 60 % of the field capacity. Samples were incubated in the dark at a constant temperature of 22°C ± 1°C. A sub-sample of 5 g was taken from each flask at day 0 (after application), 1, 3, 7, 15, 20, 28, 44 and 62. Glyphosate and AMPA in soil samples was extracted with a strong basic solution (100 mM Na2B4O7•10H2O/ 100 mM K3PO4, pH=9) and then derivitazed with FMOC-Cl. Detection and quantification of the compounds was performed by ultra-performance liquid chromatography coupled with a mass spectrometer (UPLC MS/MS). The results showed that forty percent of the applied glyphosate was degraded within the first three days in all soils, indicating a fast initial dissipation rate. However, the dissipation rate considerably decreased over time and the degradation kinetics adjusted to a two-compartment kinetic model. No differences were found between tillage practices. Dissipation was not related to the microbial activity measured as soil respiration. The fast decrease in the concentration of glyphosate at the beginning of the dissipation study was not reflected in an increase on the concentration of AMPA. The estimated half-lives for glyphosate ranged between 9 and 38 days. However, glyphosate bioavailability decreases over time as it is strongly adsorbed to the soil matrix. This increases its residence time which may lead to its accumulation in agricultural soils.

  17. Production of cellulase from Pestalotiopsis versicolor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rao, M.N.A.; Mithal, B.M.; Thakur, R.N.

    1983-01-01

    Production of cellulase from Pestalotiopsis versicolor was studied in a shake flask culture. The cellulase system was found to be rich in beta-glucosidase. Kinetic parameters such as pH and temperature have been optimized for the various enzyme components. 9 references.

  18. 40 CFR Appendix A-5 to Part 60 - Test Methods 11 through 15A

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... are needed. For the first, third, and fourth impingers, use the Greenburg-Smith design, modified by... of the flask. For the second impinger, use the Greenburg-Smith design with the standard tip. 6.1.3...

  19. 40 CFR Appendix A-5 to Part 60 - Test Methods 11 through 15A

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... noncontaminating fittings are needed. For the first, third, and fourth impingers, use the Greenburg-Smith design....) from the bottom of the flask. For the second impinger, use the Greenburg-Smith design with the standard...

  20. 40 CFR Appendix A-5 to Part 60 - Test Methods 11 through 15A

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... noncontaminating fittings are needed. For the first, third, and fourth impingers, use the Greenburg-Smith design....) from the bottom of the flask. For the second impinger, use the Greenburg-Smith design with the standard...

  1. 40 CFR Appendix A-5 to Part 60 - Test Methods 11 through 15A

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... noncontaminating fittings are needed. For the first, third, and fourth impingers, use the Greenburg-Smith design....) from the bottom of the flask. For the second impinger, use the Greenburg-Smith design with the standard...

  2. 40 CFR Appendix A-5 to Part 60 - Test Methods 11 through 15A

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... noncontaminating fittings are needed. For the first, third, and fourth impingers, use the Greenburg-Smith design....) from the bottom of the flask. For the second impinger, use the Greenburg-Smith design with the standard...

  3. 76 FR 53678 - Notice of Intent To Suspend Certain Pesticide Registrations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-29

    ...- 12/14/2007 12/24/2007 8/20/2008 No data received. octanol/water) shake flask method. 19713-289 830.7570 Partition coefficient (n- 12/14/2007 12/24/2007 8/20/2008 No data received. octanol/water...

  4. 77 FR 10520 - Notice of Intent To Suspend Certain Pesticide Registrations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-22

    .../2007 12/24/2007 8/20/2008 No data coefficient (n- received. octanol/water) shake flask method. 19713-72......... 830.7570 Partition 12/14/2007 12/24/2007 8/20/2008 No data coefficient (n- received. octanol/water...

  5. BIODEGRADATION OF FLUORANTHENE AS MONITORED USING STABLE CARBON ISOTOPES

    EPA Science Inventory

    The measurement of stable isotope ratios of carbon (d13C values) was investigated as a viable technique to monitor the intrinsic bioremediation of polycyclic aromatic hydrocarbons (PAHs). Biometer-flask experiments were conducted in which the bacterium, Sphingomonas paucimobilis,...

  6. Atmospheric CO2 Concentrations Derived from Flask Samples Collected at U.S.S.R.-Operated Sampling Sites (1991) (NDP-033)

    DOE Data Explorer

    Brounshtein, A. M. [Main Geophysical Observatory, Hydrometeorological Service of the U.S.S.R., St. Petersburg, U.S.S.R.; Faber, E. V. [Main Geophysical Observatory, Hydrometeorological Service of the U.S.S.R., St. Petersburg, U.S.S.R.; Shashkov, A. A. [Main Geophysical Observatory, Hydrometeorological Service of the U.S.S.R., St. Petersburg, U.S.S.R.

    1991-01-01

    This NDP represents the first CDIAC data package to result from our involvement with Soviet scientists as part of Working Group (WG) VIII of the U.S.-U.S.S.R. Joint Committee on Cooperation in the Field of Environmental Protection. The U.S.-U.S.S.R. Agreement on Protection of the Environment, established in 1972, covers a wide variety of areas, including environmental pollution, the urban environment, nature preserves, arctic and subarctic ecological systems, earthquake prediction, and institutional measures for environmental protection. WG VIII is concerned with the influence of environmental changes on climate. CDIAC's activities have been conducted under the auspices of WG VIII's "Data Exchange Management" project. (The four other WG VIII projects deal with climate change, atmospheric composition, clouds and radiation fluxes, and stratospheric ozone.) In addition to the Main Geophysical Observatory, other Soviet institutions that have been cooperating with CDIAC in the exchange of CO2 and climate-related data include the All-Union Research Institute of Hydrometeorological Information (Obninsk) and the State Hydrological Institute (St. Petersburg).

  7. Air bubbles and hemolysis of blood samples during transport by pneumatic tube systems.

    PubMed

    Mullins, Garrett R; Bruns, David E

    2017-10-01

    Transport of blood samples through pneumatic tube systems (PTSs) generates air bubbles in transported blood samples and, with increasing duration of transport, the appearance of hemolysis. We investigated the role of air-bubble formation in PTS-induced hemolysis. Air was introduced into blood samples for 0, 1, 3 or 5min to form air bubbles. Hemolysis in the blood was assessed by (H)-index, lactate dehydrogenase (LD) and potassium in plasma. In an effort to prevent PTS-induced hemolysis, blood sample tubes were completely filled, to prevent air bubble formation, and compared with partially filled samples after PTS transport. We also compared hemolysis in anticoagulated vs clotted blood subjected to PTS transport. As with transport through PTSs, the duration of air bubble formation in blood by a gentle stream of air predicted the extent of hemolysis as measured by H-index (p<0.01), LD (p<0.01), and potassium (p<0.02) in plasma. Removing air space in a blood sample prevented bubble formation and fully protected the blood from PTS-induced hemolysis (p<0.02 vs conventionally filled collection tube). Clotted blood developed less foaming during PTS transport and was partially protected from hemolysis vs anticoagulated blood as indicated by lower LD (p<0.03) in serum than in plasma after PTS sample transport. Prevention of air bubble formation in blood samples during PTS transport protects samples from hemolysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Uncertainties in monitoring of SVOCs in air caused by within-sampler degradation during active and passive air sampling

    NASA Astrophysics Data System (ADS)

    Melymuk, Lisa; Bohlin-Nizzetto, Pernilla; Prokeš, Roman; Kukučka, Petr; Přibylová, Petra; Vojta, Šimon; Kohoutek, Jiří; Lammel, Gerhard; Klánová, Jana

    2017-10-01

    Degradation of semivolatile organic compounds (SVOCs) occurs naturally in ambient air due to reactions with reactive trace gases (e.g., ozone, NOx). During air sampling there is also the possibility for degradation of SVOCs within the air sampler, leading to underestimates of ambient air concentrations. We investigated the possibility of this sampling artifact in commonly used active and passive air samplers for seven classes of SVOCs, including persistent organic pollutants (POPs) typically covered by air monitoring programs, as well as SVOCs of emerging concern. Two active air samplers were used, one equipped with an ozone denuder and one without, to compare relative differences in mass of collected compounds. Two sets of passive samplers were also deployed to determine the influence of degradation during longer deployment times in passive sampling. In active air samplers, comparison of the two sampling configurations suggested degradation of particle-bound polycyclic aromatic hydrocarbons (PAHs), with concentrations up to 2× higher in the denuder-equipped sampler, while halogenated POPs did not have clear evidence of degradation. In contrast, more polar, reactive compounds (e.g., organophosphate esters and current use pesticides) had evidence of losses in the sampler with denuder. This may be caused by the denuder itself, suggesting sampling bias for these compounds can be created when typical air sampling apparatuses are adapted to limit degradation. Passive air samplers recorded up to 4× higher concentrations when deployed for shorter consecutive sampling periods, suggesting that within-sampler degradation may also be relevant in passive air monitoring programs.

  9. Radon emanation of heterogeneous basin deposits in Kathmandu Valley, Nepal

    NASA Astrophysics Data System (ADS)

    Girault, Frédéric; Gajurel, Ananta Prasad; Perrier, Frédéric; Upreti, Bishal Nath; Richon, Patrick

    2011-01-01

    Effective radium-226 concentration ( EC Ra) has been measured in soil samples from seven horizontal and vertical profiles of terrace scarps in the northern part of Kathmandu Valley, Nepal. The samples belong to the Thimi, Gokarna, and Tokha Formations, dated from 50 to 14 ky BP, and represent a diverse fluvio-deltaic sedimentary facies mainly consisting of gravelly to coarse sands, black, orange and brown clays. EC Ra was measured in the laboratory by radon-222 emanation. The samples ( n = 177) are placed in air-tight glass containers, from which, after an accumulation time varying from 3 to 18 days, the concentration of radon-222, radioactive decay product of radium-226 and radioactive gas with a half-life of 3.8 days, is measured using scintillation flasks. The EC Ra values from the seven different profiles of the terrace deposits vary from 0.4 to 43 Bq kg -1, with profile averages ranging from 12 ± 1 to 27 ± 2 Bq kg -1. The values have a remarkable consistency along a particular horizon of sediment layers, clearly demonstrating that these values can be used for long distance correlations of the sediment horizons. Widely separated sediment profiles, representing similar stratigraphic positions, exhibit consistent EC Ra values in corresponding stratigraphic sediment layers. EC Ra measurements therefore appear particularly useful for lithologic and stratigraphic discriminations. For comparison, EC Ra values of soils from different localities having various sources of origin were also obtained: 9.2 ± 0.4 Bq kg -1 in soils of Syabru-Bensi (Central Nepal), 23 ± 1 Bq kg -1 in red residual soils of the Bhattar-Trisuli Bazar terrace (North of Kathmandu), 17.1 ± 0.3 Bq kg -1 in red residual soils of terrace of Kalikasthan (North of Trisuli Bazar) and 10 ± 1 Bq kg -1 in red residual soils of a site near Nagarkot (East of Kathmandu). The knowledge of EC Ra values for these various soils is important for modelling radon exhalation at the ground surface, in particular in the vicinity of active faults. Importantly, the study also reveals that, above numerous sediments of Kathmandu Valley, radon concentration in dwellings can potentially exceed the level of 300 Bq m -3 for residential areas; a fact that should be seriously taken into account by the governmental and non-governmental agencies as well as building authorities.

  10. 75 FR 29540 - Notice of Suspension of Certain Pesticide Registrations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-26

    ... (n- 59820-5 Octanol/H2O), Shake Flask Method 6297-6 830.7570 Partition August 15, 2008 August 21, 2008 April 30, 2009 No data received 59820-4 Coefficient (n- 59820-5 Octanol/H2O), Estimation by Liquid...

  11. What Drives Carbon Isotope Fractionation by the Terrestrial Biosphere?

    NASA Astrophysics Data System (ADS)

    Still, Christopher; Rastogi, Bharat

    2017-11-01

    During photosynthesis, terrestrial plants preferentially assimilate the lighter and much more abundant form of carbon, 12C, which accounts for roughly 99% of naturally occurring forms of this element. This photosynthetic preference for lighter carbon is driven principally by differences in molecular diffusion of carbon dioxide with differing 13C/12C across stomatal pores on leaves, followed by differences in carboxylation rates by the Rubisco enzyme that is central to the process of photosynthesis. As a result of these slight preferences, which work out to about a 2% difference in the fixation rates of 12CO2 versus 13CO2 by C3 vegetation, plant tissues are depleted in the heavier form of carbon (13C) relative to atmospheric CO2. This difference has been exploited in a wide range of scientific applications, as the photosynthetic isotope signature is passed to ecosystem carbon pools and through ecological food webs. What is less appreciated is the signature that terrestrial carbon exchanges leave on atmospheric CO2, as the net uptake of carbon by land plants during their growing season not only draws down the local CO2 concentration, it also leaves behind relatively more CO2 molecules containing 13C. The converse happens outside the growing season, when autotrophic and heterotrophic respiration predominate. During these periods, atmospheric CO2 concentration increases and its corresponding carbon isotope composition becomes relatively depleted in 13C as the products of photosynthesis are respired, along with some small isotope fractionation that happen downstream of the initial photosynthetic assimilation. Similar phenomena were first observed at shorter time scales by the eminent carbon cycle scientist, Charles (Dave) Keeling. Keeling collected samples of air in glass flasks from sites along the Big Sur coast that he later measured for CO2 concentration and carbon isotope composition (δ13C) in his lab (Keeling, 1998). From these samples, Keeling observed increasing CO2 concentrations at night compared to the day, along with corresponding depletions in their δ13C. These phenomena were understood at the time to be driven by interactions between ecosystem carbon exchanges and vertical movements of the atmospheric boundary layer (Keeling, 1958).

  12. Making Carbon Emissions Remotely Sensible: Flux Observations of Carbon from an Airborne Laboratory (FOCAL), its Near-Surface Survey of Carbon Gases and Isotopologues on Alaska's North Slope

    NASA Astrophysics Data System (ADS)

    Dobosy, R.; Dumas, E. J.; Sayres, D. S.; Healy, C. E.; Munster, J. B.; Baker, B.; Anderson, J. G.

    2014-12-01

    Detailed process-oriented study of the mechanisms of conversion in the Arctic of fossil carbon to atmospheric gas is progressing, but necessarily limited to a few point locations and requiring detailed subsurface measurements inaccessible to remote sensing. Airborne measurements of concentration, transport and flux of these carbon gases at sufficiently low altitude to reflect surface variations can tie such local measurements to remotely observable features of the landscape. Carbon dioxide and water vapor have been observable for over 20 years from low-altitude small aircraft in the Arctic and elsewhere. Methane has been more difficult, requiring large powerful aircraft or limited flask samples. Recent developments in spectroscopy, however, have reduced the power and weight required to measure methane at rates suitable for eddy-covariance flux estimates. The Flux Observations of Carbon from an Airborne Laboratory (FOCAL) takes advantage of Integrated Cavity-Output Spectroscopy (ICOS) to measure CH4, CO2, and water vapor in a new airborne system. The system, moreover, measures these gases' stable isotopologues every two seconds or faster helping to separate thermogenic from biogenic emissions. Paired with the Best Airborne Turbulence (BAT) probe developed for small aircraft by NOAA's Air Resources Laboratory and a light twin-engine aircraft adapted by Aurora Flight Sciences Inc., the FOCAL measures at 6 m spacing, covering 100 km in less than 30 minutes. It flies between 10 m and 50 m above ground interspersed with profiles to the top of the boundary layer and beyond. This presentation gives an overview of the magnitude and variation in fluxes and concentrations of CH4, CO2, and H2O with space, time, and time of day in a spatially extensive survey, more than 7500 km total in 15 flights over roughly a 100 km square during the month of August 2013. An extensive data set such as this at low altitude with high-rate sampling addresses features that repeat on 1 km scale or smaller such as thermokarst lakes as well as landscape changes on the 100 km scale.

  13. Streamlined bioreactor-based production of human cartilage tissues.

    PubMed

    Tonnarelli, B; Santoro, R; Adelaide Asnaghi, M; Wendt, D

    2016-05-27

    Engineered tissue grafts have been manufactured using methods based predominantly on traditional labour-intensive manual benchtop techniques. These methods impart significant regulatory and economic challenges, hindering the successful translation of engineered tissue products to the clinic. Alternatively, bioreactor-based production systems have the potential to overcome such limitations. In this work, we present an innovative manufacturing approach to engineer cartilage tissue within a single bioreactor system, starting from freshly isolated human primary chondrocytes, through the generation of cartilaginous tissue grafts. The limited number of primary chondrocytes that can be isolated from a small clinically-sized cartilage biopsy could be seeded and extensively expanded directly within a 3D scaffold in our perfusion bioreactor (5.4 ± 0.9 doublings in 2 weeks), bypassing conventional 2D expansion in flasks. Chondrocytes expanded in 3D scaffolds better maintained a chondrogenic phenotype than chondrocytes expanded on plastic flasks (collagen type II mRNA, 18-fold; Sox-9, 11-fold). After this "3D expansion" phase, bioreactor culture conditions were changed to subsequently support chondrogenic differentiation for two weeks. Engineered tissues based on 3D-expanded chondrocytes were more cartilaginous than tissues generated from chondrocytes previously expanded in flasks. We then demonstrated that this streamlined bioreactor-based process could be adapted to effectively generate up-scaled cartilage grafts in a size with clinical relevance (50 mm diameter). Streamlined and robust tissue engineering processes, as the one described here, may be key for the future manufacturing of grafts for clinical applications, as they facilitate the establishment of compact and closed bioreactor-based production systems, with minimal automation requirements, lower operating costs, and increased compliance to regulatory guidelines.

  14. Catalytic Palladium Film Deposited by Scalable Low-Temperature Aqueous Combustion.

    PubMed

    Voskanyan, Albert A; Li, Chi-Ying Vanessa; Chan, Kwong-Yu

    2017-09-27

    This article describes a novel method for depositing a dense, high quality palladium thin film via a one-step aqueous combustion process which can be easily scaled up. Film deposition of Pd from aqueous solutions by conventional chemical or electrochemical methods is inhibited by hydrogen embrittlement, thus resulting in a brittle palladium film. The method outlined in this work allows a direct aqueous solution deposition of a mirror-bright, durable Pd film on substrates including glass and glassy carbon. This simple procedure has many advantages including a very high deposition rate (>10 cm 2 min -1 ) and a relatively low deposition temperature (250 °C), which makes it suitable for large-scale industrial applications. Although preparation of various high-quality oxide films has been successfully accomplished via solution combustion synthesis (SCS) before, this article presents the first report on direct SCS production of a metallic film. The mechanism of Pd film formation is discussed with the identification of a complex formed between palladium nitrate and glycine at low temperature. The catalytic properties and stability of films are successfully tested in alcohol electrooxidation and electrochemical oxygen reduction reaction. It was observed that combustion deposited Pd film on a glassy carbon electrode showed excellent catalytic activity in ethanol oxidation without using any binder or additive. We also report for the first time the concept of a reusable "catalytic flask" as illustrated by the Suzuki-Miyaura cross-coupling reaction. The Pd film uniformly covers the inner walls of the flask and eliminates the catalyst separation step. We believe the innovative concept of a reusable catalytic flask is very promising and has the required features to become a commercial product in the future.

  15. Significance of oxygen supply in jarosite biosynthesis promoted by Acidithiobacillus ferrooxidans.

    PubMed

    Hou, Qingjie; Fang, Di; Liang, Jianru; Zhou, Lixiang

    2015-01-01

    Jarosite [(Na+, K+, NH4+, H3O+)Fe3(SO4)2(OH)6] is an efficient scavenger for trace metals in Fe- and SO42--rich acidic water. During the biosynthesis of jarosite promoted by Acidithiobacillus ferrooxidans, the continuous supply of high oxygen levels is a common practice that results in high costs. To evaluate the function of oxygen in jarosite production by A. ferrooxidans, three groups of batch experiments with different oxygen supply levels (i.e., loading volume percentages of FeSO4 solution of 20%, 40%, and 70% v/v in the flasks), as well as three groups of sealed flask experiments with different limiting oxygen supply conditions (i.e., the solutions were not sealed at the initial stage of the ferrous oxidation reaction by paraffin but were rather sealed at the end of the ferrous oxidation reaction at 48 h), were tested. The formed Fe-precipitates were characterized via X-ray powder diffraction and scanning electron microscope-energy dispersive spectral analysis. The results showed that the biosynthesis of jarosite by A. ferrooxidans LX5 could be achieved at a wide range of solution loading volume percentages. The rate and efficiency of the jarosite biosynthesis were poorly correlated with the concentration of dissolved oxygen in the reaction solution. Similar jarosite precipitates, expressed as KFe3 (SO4) 2(OH)6 with Fe/S molar ratios between 1.61 and 1.68, were uniformly formed in unsealed and 48 h sealed flasks. These experimental results suggested that the supply of O2 was only essential in the period of the oxidation of ferrous iron to ferric but was not required in the period of ferric precipitation.

  16. Significance of Oxygen Supply in Jarosite Biosynthesis Promoted by Acidithiobacillus ferrooxidans

    PubMed Central

    Liang, Jianru; Zhou, Lixiang

    2015-01-01

    Jarosite [(Na+, K+, NH4 +, H3O+)Fe3(SO4)2(OH)6] is an efficient scavenger for trace metals in Fe- and SO4 2--rich acidic water. During the biosynthesis of jarosite promoted by Acidithiobacillus ferrooxidans, the continuous supply of high oxygen levels is a common practice that results in high costs. To evaluate the function of oxygen in jarosite production by A. ferrooxidans, three groups of batch experiments with different oxygen supply levels (i.e., loading volume percentages of FeSO4 solution of 20%, 40%, and 70% v/v in the flasks), as well as three groups of sealed flask experiments with different limiting oxygen supply conditions (i.e., the solutions were not sealed at the initial stage of the ferrous oxidation reaction by paraffin but were rather sealed at the end of the ferrous oxidation reaction at 48 h), were tested. The formed Fe-precipitates were characterized via X-ray powder diffraction and scanning electron microscope-energy dispersive spectral analysis. The results showed that the biosynthesis of jarosite by A. ferrooxidans LX5 could be achieved at a wide range of solution loading volume percentages. The rate and efficiency of the jarosite biosynthesis were poorly correlated with the concentration of dissolved oxygen in the reaction solution. Similar jarosite precipitates, expressed as KFe3 (SO4) 2(OH)6 with Fe/S molar ratios between 1.61 and 1.68, were uniformly formed in unsealed and 48 h sealed flasks. These experimental results suggested that the supply of O2 was only essential in the period of the oxidation of ferrous iron to ferric but was not required in the period of ferric precipitation. PMID:25807372

  17. Erythropoietin production from CHO cells grown by continuous culture in a fluidized-bed bioreactor.

    PubMed

    Wang, M-D; Yang, M; Huzel, N; Butler, M

    2002-01-20

    A Chinese hamster ovary (CHO) cell line that expresses human erythropoietin (huEPO) was in a 2-L Cytopilot fluidized-bed bioreactor with 400 mL macroporous Cytoline-1 microcarriers and a variable perfusion rate of serum-free and protein-free medium for 48 days. The cell density increased to a maximum of 23 x 10(6) cells/mL, beads on day 27. The EPO concentration increased to 600 U/mL during the early part of the culture period (on day 24) and increased further to 980 U/mL following the addition of a higher concentration of glucose and the addition of sodium butyrate. The EPO concentration was significantly higher (at least 2x than that in a controlled stirred-tank bioreactor, in a spinner flask, or in a stationary T-flask culture. The EPO accumulated to a total production of 28,000 kUnits over the whole culture period. The molecular characteristics of EPO with respect to size and pattern of glycosylation did not change with scale up. The pattern of utilization and production of 18 amino acids was similar in the Cytopilot culture to that in a stationary batch culture in a T-flask. The concentration of ammonia was maintained at a low level (< 2 mM) over the entire culture period. The specific rate of consumption of glucose, as well as the specific rates of production of lactate and ammonia, were constant throughout the culture period indicating a consistent metabolic behavior of the cells in the bioreactor. These results indicate the potential of the Cytopilot bioreactor culture system for the continuous production of a recombinant protein over several weeks. Copyright 2002 John Wiley & Sons, Inc.

  18. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 8 2011-07-01 2011-07-01 false Air sampling. 61.34 Section 61.34... sampling. (a) Stationary sources subject to § 61.32(b) shall locate air sampling sites in accordance with a... concentrations calculated within 30 days after filters are collected. Records of concentrations at all sampling...

  19. A high ozone episode in winter 2013 in the Uinta Basin oil and gas region characterized by aircraft measurements

    NASA Astrophysics Data System (ADS)

    Oltmans, S. J.; Karion, A.; Schnell, R. C.; Pétron, G.; Sweeney, C.; Wolter, S.; Neff, D.; Montzka, S. A.; Miller, B. R.; Helmig, D.; Johnson, B. J.; Hueber, J.

    2014-08-01

    During the winter of 2012-2013 atmospheric surface ozone mole fractions exceeded the US 8 h standard of 75 ppb on 39 days in the Uinta Basin of Utah. As part of the Uinta Basin Winter Ozone Study (UBWOS) aircraft flights were conducted throughout the basin with continuous measurements of ozone (O3), methane (CH4), carbon dioxide (CO2), carbon monoxide (CO), nitrogen dioxide (NO2), and discrete whole air flask samples for determination of ∼50 trace gases including a number of non-methane hydrocarbons (NMHCs). During the course of seven flights conducted between 31 January and 7 February 2013, coinciding with strong, multi-day temperature inversions, O3 levels gradually built up in the shallow boundary layer from ∼45 ppb to ∼140 ppb. Near-surface CH4 mole fractions increased during the episode from near background levels of ∼2 ppm to over 10 ppm. Based on elevated levels of CH4 across the basin and high correlations of CH4 with NMHCs from the discrete air samples, O3 precursor NMHCs were also inferred to be elevated throughout the basin. Discrete plumes of high NO2 were observed in the gas production region of the basin suggesting that gas processing plants and compressor facilities were important point sources of reactive nitrogen oxides (NOx). Vertical profiles obtained during the flights showed that the high O3 mole fractions (as well as other elevated constituents) were confined to a shallow layer from near the ground to 300-400 m above ground level (m a.g.l.) capped by a strong temperature inversion. The highest mole fractions of the measured constituents during the study period were in an isothermal cold layer that varied from ∼300 m depth on 4 February to ∼150 m on 5 February. A gradient layer with declining mole fractions with altitude extended above the isothermal layer to ∼1900 m a.s.l. (300-400 m a.g.l.) indicative of some mixing of air out of the boundary layer. O3 mole fractions continued to increase within the basin as the high O3 episode developed over the course of a week. CH4 mole fractions, on the other hand, leveled off after several days. On several flights, the aircraft sampled the plume of a coal-fired power plant (located east of the main gas field) flowing above the inversion layer. These measurements ruled out the effluents of the power plant as a significant source of NOx for O3 production beneath the temperature inversion in the basin. The presence of elevated O3 precursors within the basin and the rapid daytime production of O3 in the atmosphere beneath the temperature inversion both indicated that O3 was being produced from precursors emitted within the basin beneath the temperature inversion. Although observations show that horizontal winds in the surface layer were relatively light during the high ozone event, they were sufficient to disperse precursors up to 80 km from primary sources in the main gas field in the southeast quadrant to the balance of the Uinta Basin.

  20. NHEXAS PHASE I ARIZONA STUDY--METALS IN AIR ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Air data set contains analytical results for measurements of up to 11 metals in 369 air samples over 175 households. Samples were taken by pumping standardized air volumes through filters at indoor and outdoor sites around each household being sampled. The primary...

  1. Use of dust fall filters as passive samplers for metal concentrations in air for communities near contaminated mine tailings

    PubMed Central

    Beamer, P.I.; Sugeng, A. J.; Kelly, M.D.; Lothrop, N.; Klimecki, W.; Wilkinson, S.T.; Loh, M.

    2014-01-01

    Mine tailings are a source of metal exposures in many rural communities. Multiple air samples are necessary to assess the extent of exposures and factors contributing to these exposures. However, air sampling equipment is costly and requires trained personnel to obtain measurements, limiting the number of samples that can be collected. Simple, low-cost methods are needed to allow for increased sample collection. The objective of our study was to assess if dust fall filters can serve as passive air samplers and be used to characterize potential exposures in a community near contaminated mine tailings. We placed filters in cylinders, concurrently with active indoor air samplers, in 10 occupied homes. We calculated an estimated flow rate by dividing the mass on each dust fall filter by the bulk air concentration and the sampling duration. The mean estimated flow rate for dust fall filters was significantly different during sampling periods with precipitation. The estimated flow rate was used to estimate metal concentration in the air of these homes, as well as in 31 additional homes in another rural community impacted by contaminated mine tailings. The estimated air concentrations had a significant linear association with the measured air concentrations for beryllium, manganese and arsenic (p<0.05), whose primary source in indoor air is resuspended soil from outdoors. In the second rural community, our estimated metal concentrations in air were comparable to active air sampling measurements taken previously. This passive air sampler is a simple low-cost method to assess potential exposures near contaminated mining sites. PMID:24469149

  2. Downscaling the in vitro test of fungal bioremediation of polycyclic aromatic hydrocarbons: methodological approach.

    PubMed

    Drevinskas, Tomas; Mickienė, Rūta; Maruška, Audrius; Stankevičius, Mantas; Tiso, Nicola; Mikašauskaitė, Jurgita; Ragažinskienė, Ona; Levišauskas, Donatas; Bartkuvienė, Violeta; Snieškienė, Vilija; Stankevičienė, Antanina; Polcaro, Chiara; Galli, Emanuela; Donati, Enrica; Tekorius, Tomas; Kornyšova, Olga; Kaškonienė, Vilma

    2016-02-01

    The miniaturization and optimization of a white rot fungal bioremediation experiment is described in this paper. The optimized procedure allows determination of the degradation kinetics of anthracene. The miniaturized procedure requires only 2.5 ml of culture medium. The experiment is more precise, robust, and better controlled comparing it to classical tests in flasks. Using this technique, different parts, i.e., the culture medium, the fungi, and the cotton seal, can be analyzed. A simple sample preparation speeds up the analytical process. Experiments performed show degradation of anthracene up to approximately 60% by Irpex lacteus and up to approximately 40% by Pleurotus ostreatus in 25 days. Bioremediation of anthracene by the consortium of I. lacteus and P. ostreatus shows the biodegradation of anthracene up to approximately 56% in 23 days. At the end of the experiment, the surface tension of culture medium decreased comparing it to the blank, indicating generation of surfactant compounds.

  3. Metabolism of Tryptophans by Pseudomonas aureofaciens

    PubMed Central

    Elander, Richard P.; Mabe, James A.; Hamill, Robert H.; Gorman, Marvin

    1968-01-01

    Twenty-nine strains of Pseudomonas, classified as P. fluorescens biotype D or E or as P. multivorans, were examined for the production of pyrrolnitrin, an antifungal agent synthesized in P. aureofaciens. Eight strains were shown to produce pyrrolnitrin in shake-flask fermentation. Four cultures were from the multivorans taxon, and the remaining four were members of the fluorescens group. The antifungal agent produced in these strains was isolated and shown to be pyrrolnitrin by comparison with an authentic sample. The strains differed markedly with respect to the amount of pyrrolnitrin produced and in their utilization of exogenous tryptophan. Secondary metabolites, not related to pyrrolnitrin, were also examined and compared with those synthesized in P. aureofaciens. Marked differences were noted in both phenazine pigments and phenolic metabolites. The results of the study suggest that the production of pyrrolnitrin may be widespread in selected taxonomic groups of Pseudomonas. Images Fig. 1 PMID:4968963

  4. Determination of Root Exudates in a Steril Continuous Flow Culture. I. The Culture Method

    PubMed Central

    Richter, Martin; Wilms, Werner; Scheffer, Fritz

    1968-01-01

    A sterile plant culture consisting of culture vessels, culture solution container, collecting flasks for percolating nutrient solution, illumination and aeration systems and a suitable pump is described. Its difference with other culture methods is a very slow, continuous percolation of the nutrient solution through the rooting medium. Well defined and controllable conditions can thus be established in the rhizosphere over long culture periods. Samples can be collected at short intervals without disturbing the rhizosphere in any way nor endangering the sterility of the culture. One of the fundamental factors determining the special ecological characteristics of the plant rhizosphere is the liberation of organic and inorganic substances by the plant root. During the study of this phenomenon it became evident that the amount of substances liberated varies within wide limits (factors 100 to 1000) according to the conditions in which the root is developing. PMID:16656966

  5. Filter for on-line air monitor unaffected by radon progeny and method of using same

    DOEpatents

    Phillips, Terrance D.; Edwards, Howard D.

    1999-01-01

    An apparatus for testing air having contaminants and radon progeny therein. The apparatus includes a sampling box having an inlet for receiving the air and an outlet for discharging the air. The sampling box includes a filter made of a plate of sintered stainless steel. The filter traps the contaminants, yet allows at least a portion of the radon progeny to pass therethrough. A method of testing air having contaminants and radon progeny therein. The method includes providing a testing apparatus that has a sampling box with an inlet for receiving the air and an outlet for discharging the air, and has a sintered stainless steel filter disposed within said sampling box; drawing air from a source into the sampling box using a vacuum pump; passing the air through the filter; monitoring the contaminants trapped by the filter; and providing an alarm when a selected level of contaminants is reached. The filter traps the contaminants, yet allows at least a portion of the radon progeny to pass therethrough.

  6. 21 CFR 177.1970 - Vinyl chloride-lauryl vinyl ether copolymers.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... filter paper with the aid of suction. Transfer the filtrate to flat glass dishes that are warmed on a hot.... Maintain the temperature of the contents of the flask at 150 °F for 2 hours using a hot plate while also...

  7. 21 CFR 177.1970 - Vinyl chloride-lauryl vinyl ether copolymers.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... filter paper with the aid of suction. Transfer the filtrate to flat glass dishes that are warmed on a hot.... Maintain the temperature of the contents of the flask at 150 °F for 2 hours using a hot plate while also...

  8. 21 CFR 177.1970 - Vinyl chloride-lauryl vinyl ether copolymers.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... filter paper with the aid of suction. Transfer the filtrate to flat glass dishes that are warmed on a hot.... Maintain the temperature of the contents of the flask at 150 °F for 2 hours using a hot plate while also...

  9. 21 CFR 177.1970 - Vinyl chloride-lauryl vinyl ether copolymers.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... filter paper with the aid of suction. Transfer the filtrate to flat glass dishes that are warmed on a hot.... Maintain the temperature of the contents of the flask at 150 °F for 2 hours using a hot plate while also...

  10. The Determination of the Concentrations of Sugar Solutions by Laser Refractometry.

    ERIC Educational Resources Information Center

    Hughes, Elvin, Jr.; And Others

    1988-01-01

    Presents an easily performed experiment to determine sucrose concentrations using a laser and a hollow glass prism. The experiment is suggested for high school, freshman college, and instrumental analysis classes. Notes an Erlenmeyer flask can be used instead of a prism. (MVL)

  11. 49 CFR 173.320 - Cryogenic liquids; exceptions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... atmospheric gases and helium: (1) During loading and unloading operations (pressure rises may exceed 25.3 psig...; exceptions. (a) Atmospheric gases and helium, cryogenic liquids, in Dewar flasks, insulated cylinders... the pressure in such packagings will not exceed 25.3 psig under ambient temperature conditions during...

  12. OIL SPILL DISPERSANT EFFECTIVENESS PROTOCOL. I: IMPACT OF OPERATIONAL VARIABLES

    EPA Science Inventory

    The current U.S. Environmental Protection Agency protocol for testing the effectiveness of dispersants, the swirling flask test, has been found to give widely varying results in the hands of different testing laboratories. The sources of the ambiguities in the test were determin...

  13. An effective system to produce smoke solutions from dried plant tissue for seed germination studies1

    PubMed Central

    Coons, Janice; Coutant, Nancy; Lawrence, Barbara; Finn, Daniel; Finn, Stephanie

    2014-01-01

    • Premise of the study: An efficient and inexpensive system was developed to produce smoke solutions from plant material to research the influence of water-soluble compounds from smoke on seed germination. • Methods and Results: Smoke solutions (300 mL per batch) were produced by burning small quantities (100–200 g) of dried plant material from a range of species in a bee smoker attached by a heater hose to a side-arm flask. The flask was attached to a vacuum water aspirator, to pull the smoke through the water. The entire apparatus was operated in a laboratory fume hood. • Conclusions: Compared with other smoke solution preparation systems, the system described is easy to assemble and operate, inexpensive to build, and effective at producing smoke solutions from desired species in a small indoor space. Quantitative measurements can be made when using this system, allowing for replication of the process. PMID:25202613

  14. Identifying and overcoming the effect of mass transfer limitation on decreased yield in enzymatic hydrolysis of lignocellulose at high solid concentrations.

    PubMed

    Du, Jian; Cao, Yuan; Liu, Guodong; Zhao, Jian; Li, Xuezhi; Qu, Yinbo

    2017-04-01

    Cellulose conversion decreases significantly with increasing solid concentrations during enzymatic hydrolysis of insoluble lignocellulosic materials. Here, mass transfer limitation was identified as a significant determining factor of this decrease by studying the hydrolysis of delignified corncob residue in shake flask, the most used reaction vessel in bench scale. Two mass transfer efficiency-related factors, mixing speed and flask filling, were shown to correlate closely with cellulose conversion at solid loadings higher than 15% DM. The role of substrate characteristics in mass transfer performance was also significant, which was revealed by the saccharification of two corn stover substrates with different pretreatment methods at the same solid loading. Several approaches including premix, fed-batch operation, and particularly the use of horizontal rotating reactor were shown to be valid in facilitating cellulose conversion via improving mass transfer efficiency at solid concentrations higher than 15% DM. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Production of poly-beta-hydroxybutyric acid by microorganisms accumulated from river water using a two-stage perfusion culture system.

    PubMed

    Morimoto, T; Tashiro, F; Nagashima, H; Nishizawa, K; Nagata, F; Yokogawa, Y; Suzuki, T

    2000-01-01

    The perfusion culture system using a shaken ceramic membrane flask (SCMF) was employed to accumulate microorganisms separated from river water and to produce poly-beta-hydroxybutyric acid (PHB). Using a two-step culture method with a single SCMF, river microorganisms were cultured by separately feeding four representative carbon sources, n-propanol, lactic acid, methanol, and formic acid. After 140 h culture, the cell concentration and PHB content respectively reached 43 g/l and 35% when a propanol medium was fed. Using a two-stage perfusion culture with twin SCMFs, the seed cell mass was increased in the first SCMF and then supplied to the second flask for PHB production. As a consequence, the cellular PHB content rose to 51% in the second SCMF, while the cell concentration gradually increased to 25 g/l after 175 h perfusion culture. These results demonstrated the utility of the two-stage perfusion culture system for developing a cheap means of producing PHB coincident with wastewater treatment.

  16. Development of Microtiter Plate Culture Method for Rapid Screening of ε-Poly-L-Lysine-Producing Strains.

    PubMed

    Liu, Yong-Juan; Chen, Xu-Sheng; Zhao, Jun-Jie; Pan, Long; Mao, Zhong-Gui

    2017-12-01

    ε-Poly-L-lysine (ε-PL) produced by Streptomyces albulus possesses a broad spectrum of antimicrobial activity and is widely used as a food preservative. To extensively screen ε-PL-overproducing strain, we developed an integrated high-throughput screening assay using ribosome engineering technology. The production protocol was scaled down to 24- and 48-deep-well microtiter plates (MTPs). The microplate reader assay was used to monitor ε-PL production. A good correlation was observed between the fermentation results obtained in both 24-(48)-deep-well MTPs and conventional Erlenmeyer flasks. Using this protocol, the production of ε-PL in an entire MTP was determined in <5 min without compromising on accuracy. The high-yielding strain selected through this protocol was also tested in Erlenmeyer flasks. The result showed that the ε-PL production of the high-yielding mutants was nearly 45% higher than that of the parent stain. Thus, development of this protocol is expected to accelerate the selection of ε-PL-overproducing strains.

  17. [Enhanced ε-poly-L-lysine production by improving cellular activity during fermentation].

    PubMed

    Liu, Shengrong; Wu, Qingping; Zhang, Jumei; Yang, Xiaojuan; Cai, Shuzhen

    2015-06-04

    To assess the effect of cellular activity on ε-poly-1-lysine (ε-PL) biosynthesis and thereby to rationally improve the production, we studied the cellular activity, ε-PL formation and other parameters cross flask fermentation by Streptomyces ahygroscopicus. Laser scanning confocal microscopy and a colorimetric method were used to determine cellular activity using BacLight Live/Dead and 5-cyano-2,3-ditolyl tetrazolium chloride (CTC) as viable stains. To enhance the activity of the cells in the ε-PL production period, yeast extract was added. During ε-PL submerged fermentation in flasks, most cells were active in the growth period (0 - 16 h); cells had metabolic activity in the growth and earlier ε-PL production periods between 0 and 30 h fermentation. Almost no activity was detected after 48 h fermentation when no ε-PL was produced. The improved fermentation achieved 2. 24 g/L ε-PL from 1.04 g/L. Biosynthesis of ε-PL can be boosted by up-regulating cell activity in its production phase.

  18. Cost analysis in laccase production.

    PubMed

    Osma, Johann F; Toca-Herrera, José L; Rodríguez-Couto, Susana

    2011-11-01

    In this paper the cost of producing the enzyme laccase by the white-rot fungus Trametes pubescens under both submerged (SmF) and solid-state fermentation (SSF) conditions was studied. The fungus was cultured using more than 45 culture medium compositions. The cost of production was estimated by analyzing the cost of the culture medium, the cost of equipment and the operating costs. The cost of the culture medium represented, in all cases, the highest contribution to the total cost, while, the cost of equipment was significantly low, representing less than 2% of the total costs. The cultivation under SSF conditions presented a final cost 50-fold lower than the one obtained when culturing under SmF conditions at flask scale. In addition, the laccase production under SSF conditions in tray bioreactors reduced the final cost 4-fold compared to the one obtained under SSF conditions at flask scale, obtaining a final price of 0.04 cent €/U. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. [Isolation, identification and characterization of a diethylstilbestrol-degrading bacterial strain Serratia sp].

    PubMed

    Xu, Ran-Fang; Sun, Min-Xia; Liu, Juan; Wang, Hong; Li, Xin; Zhu, Xue-Zhu; Ling, Wan-Ting

    2014-08-01

    Utilizing the diethylstilbestrol (DES)-degrading bacteria to biodegrade DES is a most reliable technique for cleanup of DES pollutants from the environment. However, little information is available heretofore on the isolation of DES-degrading bacteria and their DES removal performance in the environment. A novel bacterium capable of degrading DES was isolated from the activated sludge of a wastewater treatment plant. According to its morphology, physiochemical characteristics, and 16S rDNA sequence analysis, this strain was identified as Serratia sp.. The strain was an aerobic bacterium, and it could degrade 68.3% of DES (50 mg x L(-1)) after culturing for 7 days at 30 degrees C, 150 r x min(-1) in shaking flasks. The optimal conditions for DES biodegradation by the obtained strain were 30 degrees C, 40-60 mg x L(-1) DES, pH 7.0, 5% of inoculation volume, 0 g x L(-1) of added NaCl, and 10 mL of liquid medium volume in 100 mL flask.

  20. Aeolian comminution experiments revealing surprising sandball mineral aggregates

    NASA Astrophysics Data System (ADS)

    Nørnberg, P.; Bak, E.; Finster, K.; Gunnlaugsson, H. P.; Iversen, J. J.; Jensen, S. Knak; Merrison, J. P.

    2014-06-01

    We have undertaken a set of wind erosion experiments on a simple and well defined mineral, quartz. In these experiments wind action is simulated by end over end tumbling of quartz grains in a sealed quartz flask. The tumbling induces collisions among the quartz grains and the walls of the flask. This process simulates wind action impact speed of ∼1.2 m/s. After several months of tumbling we observed the formation of a large number of spherical sand aggregates, which resemble small snowballs under optical microscopy. Upon mechanical load the aggregates are seen to be more elastic than quartz and their mechanical strength is comparable, though slightly lower than that of sintered silica aerogels. Aggregates of this kind have not been reported from field sites or from closed circulation systems. However, sparse occurrence might explain this, or in nature the concentration of the aggregate building particles is so low that they never meet and just appear as the most fine grained tail of the sediment particle size distribution.

  1. Effect of simulated microgravity and shear stress on microcin B17 production by Escherichia coli and on its excretion into the medium

    NASA Technical Reports Server (NTRS)

    Fang, A.; Pierson, D. L.; Koenig, D. W.; Mishra, S. K.; Demain, A. L.

    1997-01-01

    Production of the antibacterial polypeptide microcin B17 (MccB17) by Escherichia coli ZK650 was inhibited by simulated microgravity. The site of MccB17 accumulation was found to be different, depending on whether the organism was grown in shaking flasks or in rotating bioreactors designed to establish a simulated microgravity environment. In flasks, the accumulation was cellular, but in the reactors, virtually all the microcin was found in the medium. The change from a cellular site to an extracellular one was apparently not a function of gravity, since extracellular production occurred in these bioreactors, irrespective of whether they were operated in the simulated microgravity or normal gravity mode. More probably, excretion is due to the much lower degree of shear stress in the bioreactors. Addition of even a single glass bead to the 50-ml medium volume in the bioreactor created enough shear to change the site of MccB17 accumulation from the medium to the cells.

  2. Impact of carbon and nitrogen feeding strategy on high production of biomass and docosahexaenoic acid (DHA) by Schizochytrium sp. LU310.

    PubMed

    Ling, Xueping; Guo, Jing; Liu, Xiaoting; Zhang, Xia; Wang, Nan; Lu, Yinghua; Ng, I-Son

    2015-05-01

    A new isolated Schizochytrium sp. LU310 from the mangrove forest of Wenzhou, China, was found as a high producing microalga of docosahexaenoic acid (DHA). In this study, the significant improvements for DHA fermentation by the batch mode in the baffled flasks (i.e. higher oxygen supply) were achieved. By applied the nitrogen-feeding strategy in 1000 mL baffled flasks, the biomass, DHA concentration and DHA productivity were increased by 110.4%, 117.9% and 110.4%, respectively. Moreover, DHA concentration of 21.06 g/L was obtained by feeding 15 g/L of glucose intermittently, which was an increase of 41.25% over that of the batch mode. Finally, an innovative strategy was carried out by intermittent feeding carbon and simultaneously feeding nitrogen. The maximum DHA concentration and DHA productivity in the fed-batch cultivation reached to 24.74 g/L and 241.5 mg/L/h, respectively. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Simultaneous treatment of food-waste recycling wastewater and cultivation of Tetraselmis suecica for biodiesel production.

    PubMed

    Heo, Sung-Woon; Ryu, Byung-Gon; Nam, Kibok; Kim, Woong; Yang, Ji-Won

    2015-07-01

    There is an increasing interest in the use of cultivated microalgae to simultaneously produce biodiesel and remove nutrients from various wastewaters. For this purpose, Tetraselmis suecica was cultivated in flasks and fermenters using diluted food-waste recycling wastewater (FRW). The effect of FRW dilution on T. suecica growth and nutrient removal was initially tested in flasks. The maximal microalgal concentration after 14 days was in medium with a twofold dilution (28.3 × 10(6) cells/mL) and a fivefold dilution (25.5 × 10(6) cells/mL). When fivefold diluted medium was used in fermenters, the final dry cell weight of T. suecica was 2.0 g/L. The removal efficiencies of ammonium and phosphate in the fermenters were 99.0 and 52.3%, respectively. In comparison with the results of previous studies, the growth data of T. suecica in the FRW medium indicate that microalgal cultivation system incorporating removal of nutrients in FRW is feasible at the field level.

  4. QSAR models for predicting octanol/water and organic carbon/water partition coefficients of polychlorinated biphenyls.

    PubMed

    Yu, S; Gao, S; Gan, Y; Zhang, Y; Ruan, X; Wang, Y; Yang, L; Shi, J

    2016-04-01

    Quantitative structure-property relationship modelling can be a valuable alternative method to replace or reduce experimental testing. In particular, some endpoints such as octanol-water (KOW) and organic carbon-water (KOC) partition coefficients of polychlorinated biphenyls (PCBs) are easier to predict and various models have been already developed. In this paper, two different methods, which are multiple linear regression based on the descriptors generated using Dragon software and hologram quantitative structure-activity relationships, were employed to predict suspended particulate matter (SPM) derived log KOC and generator column, shake flask and slow stirring method derived log KOW values of 209 PCBs. The predictive ability of the derived models was validated using a test set. The performances of all these models were compared with EPI Suite™ software. The results indicated that the proposed models were robust and satisfactory, and could provide feasible and promising tools for the rapid assessment of the SPM derived log KOC and generator column, shake flask and slow stirring method derived log KOW values of PCBs.

  5. Airborne detection and quantification of swine influenza a virus in air samples collected inside, outside and downwind from swine barns.

    PubMed

    Corzo, Cesar A; Culhane, Marie; Dee, Scott; Morrison, Robert B; Torremorell, Montserrat

    2013-01-01

    Airborne transmission of influenza A virus (IAV) in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m³ of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m³ of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m³. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions.

  6. Airborne Detection and Quantification of Swine Influenza A Virus in Air Samples Collected Inside, Outside and Downwind from Swine Barns

    PubMed Central

    Corzo, Cesar A.; Culhane, Marie; Dee, Scott; Morrison, Robert B.; Torremorell, Montserrat

    2013-01-01

    Airborne transmission of influenza A virus (IAV) in swine is speculated to be an important route of virus dissemination, but data are scarce. This study attempted to detect and quantify airborne IAV by virus isolation and RRT-PCR in air samples collected under field conditions. This was accomplished by collecting air samples from four acutely infected pig farms and locating air samplers inside the barns, at the external exhaust fans and downwind from the farms at distances up to 2.1 km. IAV was detected in air samples collected in 3 out of 4 farms included in the study. Isolation of IAV was possible from air samples collected inside the barn at two of the farms and in one farm from the exhausted air. Between 13% and 100% of samples collected inside the barns tested RRT-PCR positive with an average viral load of 3.20E+05 IAV RNA copies/m3 of air. Percentage of exhaust positive air samples also ranged between 13% and 100% with an average viral load of 1.79E+04 RNA copies/m3 of air. Influenza virus RNA was detected in air samples collected between 1.5 and 2.1 Km away from the farms with viral levels significantly lower at 4.65E+03 RNA copies/m3. H1N1, H1N2 and H3N2 subtypes were detected in the air samples and the hemagglutinin gene sequences identified in the swine samples matched those in aerosols providing evidence that the viruses detected in the aerosols originated from the pigs in the farms under study. Overall our results indicate that pigs can be a source of IAV infectious aerosols and that these aerosols can be exhausted from pig barns and be transported downwind. The results from this study provide evidence of the risk of aerosol transmission in pigs under field conditions. PMID:23951164

  7. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--METALS IN AIR ANALYTICAL RESULTS

    EPA Science Inventory

    The Metals in Air data set contains analytical results for measurements of up to 11 metals in 344 air samples over 86 households. Samples were taken by pumping standardized air volumes through filters at indoor and outdoor sites around each household being sampled. The primary ...

  8. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR PREPARATION OF FILTERS AND PUF FOR FIELD COLLECTION OF METALS AND PESTICIDES IN AIR (BCO-L-2.0)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for pre-cleaning filters and polyurethane foam (PUF) plug prior to air sampling with these media. The sampling media are used for sampling indoor air, outdoor air, and personal air. This procedure was followed to ensure consi...

  9. An automated atmospheric sampling system operating on 747 airliners

    NASA Technical Reports Server (NTRS)

    Perkins, P.; Gustafsson, U. R. C.

    1975-01-01

    An air sampling system that automatically measures the temporal and spatial distribution of selected particulate and gaseous constituents of the atmosphere has been installed on a number of commercial airliners and is collecting data on commercial air routes covering the world. Measurements of constituents related to aircraft engine emissions and other pollutants are made in the upper troposphere and lower stratosphere (6 to 12 km) in support of the Global Air Sampling Program (GASP). Aircraft operated by different airlines sample air at latitudes from the Arctic to Australia. This system includes specialized instrumentation for measuring carbon monoxide, ozone, water vapor, and particulates, a special air inlet probe for sampling outside air, a computerized automatic control, and a data acquisition system. Air constituents and related flight data are tape recorded in flight for later computer processing on the ground.

  10. Aqueous solubility, effects of salts on aqueous solubility, and partitioning behavior of hexafluorobenzene: experimental results and COSMO-RS predictions.

    PubMed

    Schröder, Bernd; Freire, Mara G; Varanda, Fatima R; Marrucho, Isabel M; Santos, Luís M N B F; Coutinho, João A P

    2011-07-01

    The aqueous solubility of hexafluorobenzene has been determined, at 298.15K, using a shake-flask method with a spectrophotometric quantification technique. Furthermore, the solubility of hexafluorobenzene in saline aqueous solutions, at distinct salt concentrations, has been measured. Both salting-in and salting-out effects were observed and found to be dependent on the nature of the cationic/anionic composition of the salt. COSMO-RS, the Conductor-like Screening Model for Real Solvents, has been used to predict the corresponding aqueous solubilities at conditions similar to those used experimentally. The prediction results showed that the COSMO-RS approach is suitable for the prediction of salting-in/-out effects. The salting-in/-out phenomena have been rationalized with the support of COSMO-RS σ-profiles. The prediction potential of COSMO-RS regarding aqueous solubilities and octanol-water partition coefficients has been compared with typically used QSPR-based methods. Up to now, the absence of accurate solubility data for hexafluorobenzene hampered the calculation of the respective partition coefficients. Combining available accurate vapor pressure data with the experimentally determined water solubility, a novel air-water partition coefficient has been derived. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Development of a Prototype Algal Reactor for Removing CO2 from Cabin Air

    NASA Technical Reports Server (NTRS)

    Patel, Vrajen; Monje, Oscar

    2013-01-01

    Controlling carbon dioxide in spacecraft cabin air may be accomplished using algal photobioreactors (PBRs). The purpose of this project was to evaluate the use of a commercial microcontroller, the Arduino Mega 2560, for measuring key photioreactor variables: dissolved oxygen, pH, temperature, light, and carbon dioxide. The Arduino platform is an opensource physical computing platform composed of a compact microcontroller board and a C++/C computer language (Arduino 1.0.5). The functionality of the Arduino platform can be expanded by the use of numerous add-ons or 'shields'. The Arduino Mega 2560 was equipped with the following shields: datalogger, BNC shield for reading pH sensor, a Mega Moto shield for controlling CO2 addition, as well as multiple sensors. The dissolved oxygen (DO) probe was calibrated using a nitrogen bubbling technique and the pH probe was calibrated via an Omega pH simulator. The PBR was constructed using a 2 L beaker, a 66 L box for addition of CO2, a micro porous membrane, a diaphragm pump, four 25 watt light bulbs, a MasterFiex speed controller, and a fan. The algae (wild type Synechocystis PCC6803) was grown in an aerated flask until the algae was dense enough to used in the main reactor. After the algae was grown, it was transferred to the 2 L beaker where CO2 consumption and O2 production was measured using the microcontroller sensor suite. The data was recorded via the datalogger and transferred to a computer for analysis.

  12. HIGH VOLUME INJECTION FOR GCMS ANALYSIS OF PARTICULATE ORGANIC SPECIES IN AMBIENT AIR

    EPA Science Inventory

    Detection of organic species in ambient particulate matter typically requires large air sample volumes, frequently achieved by grouping samples into monthly composites. Decreasing the volume of air sample required would allow shorter collection times and more convenient sample c...

  13. Monitoring airborne fungal spores in an experimental indoor environment to evaluate sampling methods and the effects of human activity on air sampling.

    PubMed Central

    Buttner, M P; Stetzenbach, L D

    1993-01-01

    Aerobiological monitoring was conducted in an experimental room to aid in the development of standardized sampling protocols for airborne microorganisms in the indoor environment. The objectives of this research were to evaluate the relative efficiencies of selected sampling methods for the retrieval of airborne fungal spores and to determine the effect of human activity on air sampling. Dry aerosols containing known concentrations of Penicillium chrysogenum spores were generated, and air samples were taken by using Andersen six-stage, Surface Air System, Burkard, and depositional samplers. The Andersen and Burkard samplers retrieved the highest numbers of spores compared with the measurement standard, an aerodynamic particle sizer located inside the room. Data from paired samplers demonstrated that the Andersen sampler had the highest levels of sensitivity and repeatability. With a carpet as the source of P. chrysogenum spores, the effects of human activity (walking or vacuuming near the sampling site) on air sampling were also examined. Air samples were taken under undisturbed conditions and after human activity in the room. Human activity resulted in retrieval of significantly higher concentrations of airborne spores. Surface sampling of the carpet revealed moderate to heavy contamination despite relatively low airborne counts. Therefore, in certain situations, air sampling without concomitant surface sampling may not adequately reflect the level of microbial contamination in indoor environments. PMID:8439150

  14. Carter Carburetor Weekly Air Monitoring & Sampling Report - March 7, 2013 - March 13, 2016

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  15. Concomitant production of xylanases and cellulases from Trichoderma longibrachiatum MDU-6 selected for the deinking of paper waste.

    PubMed

    Chutani, Preeti; Sharma, Krishna Kant

    2016-05-01

    Sixty fungal cultures were isolated from agricultural soil, industrial soil, forest canopy soil having decomposed leaf litter and compost samples collected from different regions of India. Fifteen fungal cultures were selected qualitatively for the production of xylanase and cellulases and were identified employing ITS, NS and MNS primers. The enzyme cocktail consisting of 3811 IU g(-1) of xylanase and 9.9 IU g(-1) of cellulase from Trichoderma longibrachiatum MDU-6 was selected quantitatively for the deinking of diverse paper wastes. The enzyme production increased two fold when produced at tray level in comparison with flasks. The enzyme cocktail was effective in the deinking of old newspaper samples with significant removal of chromophores, phenolics and hydrophobic compounds and less sugar loss. While in case of examination papers and laser printed papers, ink removal was not very significant. Moreover, the sugar loss was significantly high in case of examination papers. The deinking results were further confirmed with FTIR analysis. Deinked newspaper pulp sample shows brightness of 52%, which was 9.6% high than its control sample. The ERIC value for deinked newspaper pulp was found to be 655.9 ppm. Thereafter, the deinked newspaper pulp was examined under light microscope after differential staining with safranin and malachite green and also examined under scanning and transmission electron microscope, which revealed fibrillation and perforation.

  16. Air sampling workshop: October 24-25, 1978

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1979-06-01

    A two-day workshop was held in October 1978 on air sampling strategies for the occupational environment. Strategies comprise the elements of implementing an air sampling program including deciding on the extent of sampling, selecting appropriate types of measurement, placing sampling instruments properly, and interpreting sample results correctly. All of these elements are vital in the reliable assessment of occupational exposures yet their coverage in the industrial hygiene literature is meager. Although keyed to a few introductory topics, the agenda was sufficiently informal to accommodate extemporaneous discussion on any subject related to sampling strategies. Questions raised during the workshop mirror themore » status of air sampling strategy as much as the factual information that was presented. It may be concluded from the discussion and questions that air sampling strategy is an elementary state and urgently needs concerted attention from the industrial hygiene profession.« less

  17. An automated atmospheric sampling system operating on 747 airliners

    NASA Technical Reports Server (NTRS)

    Perkins, P. J.; Gustafsson, U. R. C.

    1976-01-01

    An air sampling system that automatically measures the temporal and spatial distribution of particulate and gaseous constituents of the atmosphere is collecting data on commercial air routes covering the world. Measurements are made in the upper troposphere and lower stratosphere (6 to 12 km) of constituents related to aircraft engine emissions and other pollutants. Aircraft operated by different airlines sample air at latitudes from the Arctic to Australia. This unique system includes specialized instrumentation, a special air inlet probe for sampling outside air, a computerized automatic control, and a data acquisition system. Air constituent and related flight data are tape recorded in flight for later computer processing on the ground.

  18. Biases in Total Precipitable Water Vapor Climatologies from Atmospheric Infrared Sounder and Advanced Microwave Scanning Radiometer

    NASA Technical Reports Server (NTRS)

    Fetzer, Eric J.; Lambrigtsen, Bjorn H.; Eldering, Annmarie; Aumann, Hartmut H.; Chahine, Moustafa T.

    2006-01-01

    We examine differences in total precipitable water vapor (PWV) from the Atmospheric Infrared Sounder (AIRS) and the Advanced Microwave Scanning Radiometer (AMSR-E) experiments sharing the Aqua spacecraft platform. Both systems provide estimates of PWV over water surfaces. We compare AIRS and AMSR-E PWV to constrain AIRS retrieval uncertainties as functions of AIRS retrieved infrared cloud fraction. PWV differences between the two instruments vary only weakly with infrared cloud fraction up to about 70%. Maps of AIRS-AMSR-E PWV differences vary with location and season. Observational biases, when both instruments observe identical scenes, are generally less than 5%. Exceptions are in cold air outbreaks where AIRS is biased moist by 10-20% or 10-60% (depending on retrieval processing) and at high latitudes in winter where AIRS is dry by 5-10%. Sampling biases, from different sampling characteristics of AIRS and AMSR-E, vary in sign and magnitude. AIRS sampling is dry by up to 30% in most high-latitude regions but moist by 5-15% in subtropical stratus cloud belts. Over the northwest Pacific, AIRS samples conditions more moist than AMSR-E by a much as 60%. We hypothesize that both wet and dry sampling biases are due to the effects of clouds on the AIRS retrieval methodology. The sign and magnitude of these biases depend upon the types of cloud present and on the relationship between clouds and PWV. These results for PWV imply that climatologies of height-resolved water vapor from AIRS must take into consideration local meteorological processes affecting AIRS sampling.

  19. 40 CFR 86.537-90 - Dynamometer test runs.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... “transient” formaldehyde exhaust sample, the “transient” dilution air sample bag, the “transient” methanol... start “transient” exhaust and dilution air bag samples to the analytical system and process the samples... Section 86.537-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...

  20. 40 CFR 86.537-90 - Dynamometer test runs.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... “transient” formaldehyde exhaust sample, the “transient” dilution air sample bag, the “transient” methanol... start “transient” exhaust and dilution air bag samples to the analytical system and process the samples... Section 86.537-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...

  1. 40 CFR 86.537-90 - Dynamometer test runs.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... “transient” formaldehyde exhaust sample, the “transient” dilution air sample bag, the “transient” methanol... start “transient” exhaust and dilution air bag samples to the analytical system and process the samples... Section 86.537-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...

  2. 21 CFR 177.2490 - Polyphenylene sulfide resins.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... titled “Oxygen Flask Combustion-Gravimetric Method for Determination of Sulfur in Organic Compounds... Park, MD 20740, or available for inspection at the National Archives and Records Administration (NARA....archives.gov/federal_register/code_of_federal_regulations/ibr_locations.html. (1) Sulfur content: 28.2-29.1...

  3. Temperature controller for crystal resonators

    NASA Technical Reports Server (NTRS)

    Turlington, T. R.

    1980-01-01

    Controller operates on less than 5W prime power and heats crystal from -10 C to 75 C in less than 45s. Unit is faster and more accurate (to within 0.7 C) than other inexpensive controllers and faster and less expensive than very precise controllers in vacuum flasks.

  4. EFFICACY OF COMMERCIAL INOCULA IN ENHANCING BIODEGRADATION OF WEATHERED CRUDE OIL CONTAMINATING A PRINCE WILLIAM SOUND BEACH

    EPA Science Inventory

    In a laboratory study evaluating the effectiveness of 10 commercial products in stimulating enhanced biodegradation of Alaska North Slope crude oil, two of the products provided significantly greater alkane degradation in closed flasks than indigenous Alaskan bacterial population...

  5. EFFICACY OF COMMERCIAL PRODUCTS IN ENHANCING OIL BIODEGRADATION IN CLOSED LABORATORY REACTORS

    EPA Science Inventory

    A laboratory screening protocol was designed and conducted to test the efficacy of eight commercial bacterial cultures and two non-bacterial products in enhancing the biodegradation of weathered Alaska North Slope crude oil in closed flasks. Three lines of evidence were used to ...

  6. 21 CFR 172.864 - Synthetic fatty alcohols.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... into a 1-liter glass-stoppered volumetric flask and adjust to volume with hexane, with mixing. n...) n-Octyl; manufactured by the hydrodimerization of 1,3-butadiene, followed by catalytic hydrogenation of the resulting dienol, and distillation to produce n-octyl alcohol with a minimum purity of 99...

  7. 21 CFR 177.2490 - Polyphenylene sulfide resins.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) FOOD FOR HUMAN CONSUMPTION (CONTINUED) INDIRECT FOOD ADDITIVES: POLYMERS Substances for Use Only as... specifications as determined by methods titled “Oxygen Flask Combustion-Gravimetric Method for Determination of... thermally cured at temperatures of 700 °F and above. (d) Polyphenylene sulfide resin coatings may be used in...

  8. 21 CFR 177.2490 - Polyphenylene sulfide resins.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) FOOD FOR HUMAN CONSUMPTION (CONTINUED) INDIRECT FOOD ADDITIVES: POLYMERS Substances for Use Only as... specifications as determined by methods titled “Oxygen Flask Combustion-Gravimetric Method for Determination of... thermally cured at temperatures of 700 °F and above. (d) Polyphenylene sulfide resin coatings may be used in...

  9. 21 CFR 177.2490 - Polyphenylene sulfide resins.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) FOOD FOR HUMAN CONSUMPTION (CONTINUED) INDIRECT FOOD ADDITIVES: POLYMERS Substances for Use Only as... specifications as determined by methods titled “Oxygen Flask Combustion-Gravimetric Method for Determination of... thermally cured at temperatures of 700 °F and above. (d) Polyphenylene sulfide resin coatings may be used in...

  10. 21 CFR 177.2490 - Polyphenylene sulfide resins.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) FOOD FOR HUMAN CONSUMPTION (CONTINUED) INDIRECT FOOD ADDITIVES: POLYMERS Substances for Use Only as... specifications as determined by methods titled “Oxygen Flask Combustion-Gravimetric Method for Determination of... thermally cured at temperatures of 700 °F and above. (d) Polyphenylene sulfide resin coatings may be used in...

  11. 78 FR 4844 - Notice of Intent To Suspend Certain Pesticide Registrations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-23

    ... water. 830.7550 Partition coefficient (n- 6/16/09 6/25/09 3/16/10 1,3 octanol/water) shake flask method. 830.7570 Partition coefficient (n- 6/16/09 6/25/09 3/16/10 1,3 octanol/water) estimation by liquid...

  12. A novel inhibitor of Lactobacillus biofilms prevents stuck fermentations in a shake flask model

    USDA-ARS?s Scientific Manuscript database

    Yeast ethanol fermentations contain contaminating bacteria and yeast, with Lactobacilli being a frequent contaminant. These bacteria tolerate the low pH and high ethanol concentrations present in the fermentation, and can decrease the ethanol yield. Fermentations are routinely treated with antibioti...

  13. Production of a recombinant phospholipase A2 in Escherichia coli using resonant acoustic mixing that improves oxygen transfer in shake flasks.

    PubMed

    Valdez-Cruz, Norma A; Reynoso-Cereceda, Greta I; Pérez-Rodriguez, Saumel; Restrepo-Pineda, Sara; González-Santana, Jesus; Olvera, Alejandro; Zavala, Guadalupe; Alagón, Alejandro; Trujillo-Roldán, Mauricio A

    2017-07-25

    Shake flasks are widely used during the development of bioprocesses for recombinant proteins. Cultures of recombinant Escherichia coli with orbital mixing (OM) have an oxygen limitation negatively affecting biomass growth and recombinant-protein production. With the aim to improve mixing and aeration in shake flask cultures, we analyzed cultures subjected to OM and the novel resonant acoustic mixing (RAM) by applying acoustic energy to E. coli BL21-Gold (DE3): a producer of recombinant phospholipase A2 (rPLA2) from Micrurus laticollaris snake venom. Comparing OM with RAM (200 rpm vs. 7.5g) at the same initial volumetric oxygen transfer coefficient (k L a ≈ 80 h -1 ) ~69% less biomass was obtained with OM compared with RAM. We analyzed two more conditions increasing agitation until maximal speed (12.5 and 20g), and ~1.6- and ~1.4-fold greater biomass was obtained as compared with cultures at 7.5g. Moreover, the specific growth rate was statistically similar in all cultures carried out in RAM, but ~1.5-fold higher than that in cultures carried out under OM. Almost half of the glucose was consumed in OM, whereas between 80 and 100% of the glucose was consumed in RAM cultures, doubling biomass per glucose yields. Differential organic acid production was observed, but acetate production was prevented at the maximal RAM (20g). The amount of rPLA2 in both, OM and RAM cultures, represented 38 ± 5% of the insoluble protein. A smaller proportion of α-helices and β-sheet of purified inclusion bodies (IBs) were appreciated by ATR-FTIR from cultures carried out under OM, than those from RAM. At maximal agitation by RAM, internal E. coli localization patterns of protein aggregation changed, as well as, IBs proteolytic degradation, in conjunction with the formation of small external vesicles, although these changes did not significantly affect the cell survival response. In moderate-cell-density recombinant E. coli BL21-Gold (DE3) cultures, the agitation increases in RAM (up to the maximum) was not enough to avoid the classical oxygen limitation that happens in OM shake flasks. However, RAM presents a decrease of oxygen limitation, resulting in a favorable effect on biomass growth and volumetric rPLA2 production. While under OM a higher recombinant protein yield was obtained.

  14. Improved ceramic slip casting technique. [application to aircraft model fabrication

    NASA Technical Reports Server (NTRS)

    Buck, Gregory M. (Inventor); Vasquez, Peter (Inventor)

    1993-01-01

    A primary concern in modern fluid dynamics research is the experimental verification of computational aerothermodynamic codes. This research requires high precision and detail in the test model employed. Ceramic materials are used for these models because of their low heat conductivity and their survivability at high temperatures. To fabricate such models, slip casting techniques were developed to provide net-form, precision casting capability for high-purity ceramic materials in aqueous solutions. In previous slip casting techniques, block, or flask molds made of plaster-of-paris were used to draw liquid from the slip material. Upon setting, parts were removed from the flask mold and cured in a kiln at high temperatures. Casting detail was usually limited with this technique -- detailed parts were frequently damaged upon separation from the flask mold, as the molded parts are extremely delicate in the uncured state, and the flask mold is inflexible. Ceramic surfaces were also marred by 'parting lines' caused by mold separation. This adversely affected the aerodynamic surface quality of the model as well. (Parting lines are invariably necessary on or near the leading edges of wings, nosetips, and fins for mold separation. These areas are also critical for flow boundary layer control.) Parting agents used in the casting process also affected surface quality. These agents eventually soaked into the mold, the model, or flaked off when releasing the case model. Different materials were tried, such as oils, paraffin, and even an algae. The algae released best, but some of it remained on the model and imparted an uneven texture and discoloration on the model surface when cured. According to the present invention, a wax pattern for a shell mold is provided, and an aqueous mixture of a calcium sulfate-bonded investment material is applied as a coating to the wax pattern. The coated wax pattern is then dried, followed by curing to vaporize the wax pattern and leave a shell mold of the calcium sulfate-bonded investment material. The shell mold is cooled to room temperature, and a ceramic slip is poured therein. After a ceramic shell of desired thickness has set up in the shell mold, excess ceramic slip is poured out. While still wet, the shell mold is peeled from the ceramic shell to expose any delicate or detailed parts, after which the ceramic shell is cured to provide a complete, detailed, precision ceramic article without parting lines.

  15. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 9 2012-07-01 2012-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34 Air...

  16. 40 CFR 61.34 - Air sampling.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 9 2013-07-01 2013-07-01 false Air sampling. 61.34 Section 61.34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Beryllium § 61.34 Air...

  17. Carter Carburetor Weekly Air Monitoring & Sampling Report - November 30, 2015 – December 6, 2015

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  18. Carter Carburetor Weekly Air Monitoring & Sampling Report - October 26, 2015 – November 1, 2015

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  19. Carter Carburetor Weekly Air Monitoring & Sampling Report - February 15, 2016 – February 21, 2016

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  20. Carter Carburetor Weekly Air Monitoring & Sampling Report - October 12, 2015 – October 18, 2015

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  1. Carter Carburetor Weekly Air Monitoring & Sampling Report - November 23, 2015 – November 29, 2015

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  2. Carter Carburetor Weekly Air Monitoring & Sampling Report - October 5, 2015 – October 11, 2015

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  3. Carter Carburetor Weekly Air Monitoring & Sampling Report - February 1, 2016 – February 7, 2016

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  4. Carter Carburetor Weekly Air Monitoring & Sampling Report - September 28, 2015 – October 4, 2015

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  5. Carter Carburetor Weekly Air Monitoring & Sampling Report - November 16, 2015 – November 22, 2015

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  6. Carter Carburetor Weekly Air Monitoring & Sampling Report - November 9, 2015 – November 15, 2015

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  7. Carter Carburetor Weekly Air Monitoring & Sampling Report - October 19, 2015 – October 25, 2015

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  8. Carter Carburetor Weekly Air Monitoring & Sampling Report - November 2, 2015 – November 8, 2015

    EPA Pesticide Factsheets

    Carter Carburetor Daily Weather Conditions, Dairly Work Activities, Daily Air Monitoring and Samplying Results, Air Monitoring/Samplying Results –Station 2 Linc 126, Air Monitoring/Sampling Results- Sation 3 Linc 123, Air Monitoring/Samplying Results-Stati

  9. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; operation; air... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.205 Approved sampling devices; operation; air flowrate...

  10. Analysis of EPA and DOE WIPP Air Sampling Data

    EPA Pesticide Factsheets

    During the April 2014 EPA visit to WIPP, EPA co-located four ambient air samplers with existing Department of Energy (DOE) ambient air samplers to independently corroborate DOE's reported air sampling results.

  11. Air and surface contamination patterns of meticillin-resistant Staphylococcus aureus on eight acute hospital wards.

    PubMed

    Creamer, E; Shore, A C; Deasy, E C; Galvin, S; Dolan, A; Walley, N; McHugh, S; Fitzgerald-Hughes, D; Sullivan, D J; Cunney, R; Coleman, D C; Humphreys, H

    2014-03-01

    Meticillin-resistant Staphylococcus aureus (MRSA) can be recovered from hospital air and from environmental surfaces. This poses a potential risk of transmission to patients. To investigate associations between MRSA isolates recovered from air and environmental surfaces with those from patients when undertaking extensive patient and environmental sampling. This was a prospective observational study of patients and their environment in eight wards of a 700-bed tertiary care hospital during 2010 and 2011. Sampling of patients, air and surfaces was carried out on all ward bays, with more extended environmental sampling in ward high-dependency bays and at particular times of the day. The genetic relatedness of isolates was determined by DNA microarray profiling and spa typing. MRSA was recovered from 30/706 (4.3%) patients and from 19/132 (14.4%) air samples. On 9/132 (6.8%) occasions both patient and air samples yielded MRSA. In 32 high-dependency bays, MRSA was recovered from 12/161 (7.4%) patients, 8/32 (25%) air samples, and 21/644 (3.3%) environmental surface samples. On 10/132 (7.6%) occasions, MRSA was isolated from air in the absence of MRSA-positive patients. Patient demographic data combined with spa typing and DNA microarray profiling revealed four likely transmission clusters, where patient and environmental isolates were deemed to be very closely related. Air sampling yielded MRSA on frequent occasions, especially in high-dependency bays. Environmental and air sampling combined with patient demographic data, spa typing and DNA microarray profiling indicated the presence of clusters that were not otherwise apparent. Copyright © 2014 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  12. Guided episodic sampling for capturing and characterizing industrial plumes

    NASA Astrophysics Data System (ADS)

    Ou-Yang, Chang-Feng; Liao, Wei-Cheng; Chang, Chih-Chung; Hsieh, Hsin-Cheng; Wang, Jia-Lin

    2018-02-01

    An integrated sampling technique, dubbed trigger sampling, was developed to capture characteristic industrial emissions or plumes. In the field experiment, a hydrogen sulfide (H2S) analyzer was used as the triggering instrument at the boundary of a refinery plant due to frequent complaints of foul smell from local residents. Ten episodic samples were captured when the H2S level surpassed the prescribed trigger level of 8.5 ppbv over a three-day period. Three non-episodic (blank) samples and 23 road-side samples were also collected for comparison. All the 36 flask samples were analyzed by gas chromatography-mass spectrometry/flame ionization detection (GC-MS/FID) for 108 volatile organic compounds (VOCs). The total VOC abundance of the event samples was exceedingly higher than the non-episodic samples by over 80 times in the extreme case. Alkanes were found to be the dominant constituents in the event samples, amounting to over 90% of the total VOC concentrations vs. only 30-40% for the blank and metropolitan samples. In addition, light alkanes in the event samples were highly correlated with the trigger species H2S (R2 = 0.82), implying their common origin. The matrix of chemical composition vs. sample types permitted easy visualization of the dominance of light alkanes for the event samples compared to other types of samples. Principle component analysis (PCA) identified two major contributors to cover 93% of the total variance arising from the 36 samples, further quantifying the distinction of the triggered episodic samples from the contrast samples. The proposed trigger sampling is a coupling of fast-and-slow measurement techniques. In this example, the fast-response H2S analyzer served to "guide" sampling to capture industrial plumes which were then characterized by a relatively slow method of GC-MS/FID for detailed chemical composition representative of the prominent sources.

  13. Fly pollination in Ceropegia (Apocynaceae: Asclepiadoideae): biogeographic and phylogenetic perspectives.

    PubMed

    Ollerton, Jeff; Masinde, Siro; Meve, Ulrich; Picker, Mike; Whittington, Andrew

    2009-06-01

    Ceropegia (Apocynaceae subfamily Asclepiadoideae) is a large, Old World genus of >180 species, all of which possess distinctive flask-shaped flowers that temporarily trap pollinators. The taxonomic diversity of pollinators, biogeographic and phylogenetic patterns of pollinator exploitation, and the level of specificity of interactions were assessed in order to begin to understand the role of pollinators in promoting diversification within the genus. Flower visitor and pollinator data for approx. 60 Ceropegia taxa were analysed with reference to the main centres of diversity of the genus and to a cpDNA-nrDNA molecular phylogeny of the genus. Ceropegia spp. interact with flower-visiting Diptera from at least 26 genera in 20 families, of which 11 genera and 11 families are pollinators. Size range of flies was 0.5-4.0 mm and approx. 94 % were females. Ceropegia from particular regions do not use specific fly genera or families, though Arabian Peninsula species are pollinated by a wider range of Diptera families than those in other regions. The basal-most clade interacts with the highest diversity of Diptera families and genera, largely due to one hyper-generalist taxon, C. aristolochioides subsp. deflersiana. Species in the more-derived clades interact with a smaller diversity of Diptera. Approximately 60 % of taxa are so far recorded as interacting with only a single genus of pollinators, the remaining 40 % being less conservative in their interactions. Ceropegia spp. can therefore be ecological specialists or generalists. The genus Ceropegia has largely radiated without evolutionary shifts in pollinator functional specialization, maintaining its interactions with small Diptera. Intriguing biogeographic and phylogenetic patterns may reflect processes of regional dispersal, diversification and subsequent specialization onto a narrower range of pollinators, though some of the findings may be caused by inconsistent sampling. Comparisons are made with other plant genera in the Aristolochiaceae and Araceae that have evolved flask-shaped flowers that trap female flies seeking oviposition sites.

  14. Heavy metals in atmospheric surrogate dry deposition

    PubMed

    Morselli; Cecchini; Grandi; Iannuccilli; Barilli; Olivieri

    1999-02-01

    This paper describes a methodological approach for the assessment of the amount of surrogate dry deposition of several toxic heavy metals (Cd, Cr, Cu, Ni, Pb, V, Zn) associated with atmospheric particulate matter at ground level. The objectives of the study were twofold: i) the evaluation of several techniques for the digestion of dry deposition samples for trace metal analysis; ii) the comparison of the results from two samplers with different collecting surfaces. A dry solid surface sampler (DRY sampler, Andersen--USA) and a water layer surface sampler (DAS sampler--MTX Italy) were employed. The samples were collected over a one-year period in an urban site of Bologna (northern Italy). A description is given of the complete procedure, from sampling to data elaboration, including sample storage, digestion and analytical methods. According to the results obtained with three different digestion techniques (Teflon bomb, microwave digester and Teflon flask with vapour cooling system), the highest recovery rate was achieved by the Teflon bomb procedure employing an NBS 1648 Standard Reference Material; 90-95% of the elements considered were recovered by dissolution in a pressurized Teflon bomb with an HNO3-HF mixture. Given these results, the technique was adopted for dry deposition sample digestion. On the basis of the amount of heavy metals measured as monthly deposition fluxes (microg/m2), the collecting efficiency of the DAS sampler for a number of elements was found to be as much as two to three times greater than that of the DRY sampler.

  15. Microbial air quality in mass transport buses and work-related illness among bus drivers of Bangkok Mass Transit Authority.

    PubMed

    Luksamijarulkul, Pipat; Sundhiyodhin, Viboonsri; Luksamijarulkul, Soavalug; Kaewboonchoo, Orawan

    2004-06-01

    The air quality in mass transport buses, especially air-conditioned buses may affect bus drivers who work full time. Bus numbers 16, 63, 67 and 166 of the Seventh Bus Zone of Bangkok Mass Transit Authority were randomly selected to investigate for microbial air quality. Nine air-conditioned buses and 2-4 open-air buses for each number of the bus (36 air-conditioned buses and 12 open-air buses) were included. Five points of in-bus air samples in each studied bus were collected by using the Millipore A ir Tester Totally, 180 and 60 air samples collected from air-conditioned buses and open-air buses were cultured for bacterial and fungal counts. The bus drivers who drove the studied buses were interviewed towards histories of work-related illness while working. The results revealed that the mean +/- SD of bacterial counts in the studied open-air buses ranged from 358.50 +/- 146.66 CFU/m3 to 506 +/- 137.62 CFU/m3; bus number 16 had the highest level. As well as the mean +/- SD of fungal counts which ranged from 93.33 +/- 44.83 CFU/m3 to 302 +/- 294.65 CFU/m3; bus number 166 had the highest level. Whereas, the mean +/- SD of bacterial counts in the studied air-conditioned buses ranged from 115.24 +/- 136.01 CFU/m3 to 244.69 +/- 234.85 CFU/m3; bus numbers 16 and 67 had the highest level. As well as the mean +/- SD of fungal counts which rangedfrom 18.84 +/- 39.42 CFU/m3 to 96.13 +/- 234.76 CFU/m3; bus number 166 had the highest level. When 180 and 60 studied air samples were analyzed in detail, it was found that 33.33% of the air samples from open-air buses and 6.11% of air samples from air-conditioned buses had a high level of bacterial counts (> 500 CFU/m3) while 6.67% of air samples from open-air buses and 2.78% of air samples from air-conditioned buses had a high level of fungal counts (> 500 CFU/m3). Data from the history of work-related illnesses among the studied bus drivers showed that 91.67% of open-air bus drivers and 57.28% of air-conditioned bus drivers had symptoms of work-related illnesses, p = 0.0185.

  16. Mount makes liquid nitrogen-cooled gamma ray detector portable

    NASA Technical Reports Server (NTRS)

    Fessler, T. E.

    1966-01-01

    Liquid nitrogen-cooled gamma ray detector system is made portable by attaching the detector to a fixture which provides a good thermal conductive path between the detector and the liquid nitrogen in a dewar flask and a low heat leak path between the detector and the external environment.

  17. 21 CFR 178.3620 - Mineral oil.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... extract in a 10-millimeter cell in the range from 260-350 mµ, inclusive, compared to the solvent control... hole bored in the center to closely fit the stem of the chromatographic tube. Suction flask. 250... surface of contained liquid to be evaporated. Spectrophotometric cells. Fused quartz cells, optical path...

  18. Modeling Impact of BRCA1 and BRCA2 Mutations in Mammary Epithelial Cells

    DTIC Science & Technology

    2012-09-01

    remaining tissue was lacerated and minced with opposing scalpels. Minced pieces were placed into a 50mL Erlenmeyer flask, containing 10mL digestion medium...Ham’s F- 12 containing insulin, penicillin, streptomycin, polymyxin B, Fungizone, 10% fetal bovine serum, collagenase, and hyaluronidase) for one

  19. Towards Improved Optical Limiters

    DTIC Science & Technology

    2002-05-03

    nitrophthalonitrile, 3.37 g of potassium carbonate, and 0.54 g of neopentyl glycol were added to 10 mL of dry DMSO in a round bottom flask. The... glycol oxygens which in turn replace the nitro groups of the phthalonitrile and form a bond. This substitution reaction produces the bridge unit as

  20. 49 CFR 173.162 - Gallium.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Gallium. 173.162 Section 173.162 Transportation... PACKAGINGS Non-bulk Packaging for Hazardous Materials Other Than Class 1 and Class 7 § 173.162 Gallium. (a) Except when packaged in cylinders or steel flasks, gallium must be packaged in packagings which meet the...

Top