NASA Astrophysics Data System (ADS)
Ma, Lin
2017-11-01
This paper develops a method for precisely determining the tension of an inclined cable with unknown boundary conditions. First, the nonlinear motion equation of an inclined cable is derived, and a numerical model of the motion of the cable is proposed using the finite difference method. The proposed numerical model includes the sag-extensibility, flexural stiffness, inclination angle and rotational stiffness at two ends of the cable. Second, the influence of the dynamic parameters of the cable on its frequencies is discussed in detail, and a method for precisely determining the tension of an inclined cable is proposed based on the derivatives of the eigenvalues of the matrices. Finally, a multiparameter identification method is developed that can simultaneously identify multiple parameters, including the rotational stiffness at two ends. This scheme is applicable to inclined cables with varying sag, varying flexural stiffness and unknown boundary conditions. Numerical examples indicate that the method provides good precision. Because the parameters of cables other than tension (e.g., the flexural stiffness and rotational stiffness at the ends) are not accurately known in practical engineering, the multiparameter identification method could further improve the accuracy of cable tension measurements.
Chang, Win-Jin; Fang, Te-Hua; Lee, Haw-Long; Yang, Yu-Ching
2005-01-01
In this paper the Rayleigh-Ritz method was used to study the scanning near-field optical microscope (SNOM) with a tapered optical fiber probe's flexural and axial sensitivity to vibration. Not only the contact stiffness but also the geometric parameters of the probe can influence the flexural and axial sensitivity to vibration. According to the analysis, the lateral and axial contact stiffness had a significant effect on the sensitivity of vibration of the SNOM's probe, each mode had a different level of sensitivity and in the first mode the tapered optical fiber probe was the most acceptive to higher levels of flexural and axial vibration. Generally, when the contact stiffness was lower, the tapered probe was more sensitive to higher levels of both axial and flexural vibration than the uniform probe. However, the situation was reversed when the contact stiffness was larger. Furthermore, the effect that the probe's length and its tapered angle had on the SNOM's probe axial and flexural vibration were significant and these two conditions should be incorporated into the design of new SNOM probes.
Aiello, Brett R; Hardy, Adam R; Cherian, Chery; Olsen, Aaron M; Orsbon, Courtney P; Hale, Melina E; Westneat, Mark W
2018-04-25
The organization of tissues in appendages often affects their mechanical properties and function. In the fish family Labridae, swimming behavior is associated with pectoral fin flexural stiffness and morphology, where fins range on a continuum from stiff to relatively flexible fins. Across this diversity, pectoral fin flexural stiffness decreases exponentially along the length of any given fin ray, and ray stiffness decreases along the chord of the fin from the leading to trailing edge. In this study, we examine the morphological properties of fin rays, including the effective modulus in bending (E), second moment of area (I), segmentation, and branching patterns, and their impact on fin ray stiffness. We quantify intrinsic pectoral fin ray stiffness in similarly sized fins of two closely related species that employ fins of divergent mechanics, the flapping Gomphosus varius and the rowing Halichoeres bivittatus. While segmentation patterns and E were similar between species, measurements of I and the number of fin ray branch nodes were greater in G. varius than in H. bivittatus. A multiple regression model found that of these variables, I was always significantly correlated with fin ray flexural stiffness and that variation in I always explained the majority of the variation in flexural stiffness. Thus, while most of the morphological variables quantified in this study correlate with fin ray flexural stiffness, second moment of area is the greatest factor contributing to variation in flexural stiffness. Further, interspecific variation in fin ray branching pattern could be used as a means of tuning the effective stiffness of the fin webbing to differences in swimming behavior and hydrodynamics. The comparison of these results to other systems begins to unveil fundamental morphological features of biological beams and yields insight into the role of mechanical properties in fin deformation for aquatic locomotion. © 2018 Wiley Periodicals, Inc.
Role of flexural stiffness of leukocyte microvilli in adhesion dynamics
NASA Astrophysics Data System (ADS)
Wu, Tai-Hsien; Qi, Dewei
2018-03-01
Previous work reported that microvillus deformation has an important influence on dynamics of cell adhesion. However, the existing studies were limited to the extensional deformation of microvilli and did not consider the effects of their bending deformation on cell adhesion. This Rapid Communication investigates the effects of flexural stiffness of microvilli on the rolling process related to adhesion of leukocytes by using a lattice-Boltzmann lattice-spring method (LLM) combined with adhesive dynamics (AD) simulations. The simulation results reveal that the flexural stiffness of microvilli and their bending deformation have a profound effect on rolling velocity and adhesive forces. As the flexural stiffness of the microvilli decreases, their bending angles increase, resulting in an increase in the number of receptor-ligand bonds and adhesive bonding force and a decrease in the rolling velocity of leukocytes. The effects of flexural stiffness on deformation and adhesion represent crucial factors involved in cell adhesion.
Flexural Stiffness of Myosin Va Subdomains as Measured from Tethered Particle Motion
Michalek, Arthur J.; Kennedy, Guy G.; Warshaw, David M.; Ali, M. Yusuf
2015-01-01
Myosin Va (MyoVa) is a processive molecular motor involved in intracellular cargo transport on the actin cytoskeleton. The motor's processivity and ability to navigate actin intersections are believed to be governed by the stiffness of various parts of the motor's structure. Specifically, changes in calcium may regulate motor processivity by altering the motor's lever arm stiffness and thus its interhead communication. In order to measure the flexural stiffness of MyoVa subdomains, we use tethered particle microscopy, which relates the Brownian motion of fluorescent quantum dots, which are attached to various single- and double-headed MyoVa constructs bound to actin in rigor, to the motor's flexural stiffness. Based on these measurements, the MyoVa lever arm and coiled-coil rod domain have comparable flexural stiffness (0.034 pN/nm). Upon addition of calcium, the lever arm stiffness is reduced 40% as a result of calmodulins potentially dissociating from the lever arm. In addition, the flexural stiffness of the full-length MyoVa construct is an order of magnitude less stiff than both a single lever arm and the coiled-coil rod. This suggests that the MyoVa lever arm-rod junction provides a flexible hinge that would allow the motor to maneuver cargo through the complex intracellular actin network. PMID:26770194
Novel parameter-based flexure bearing design method
NASA Astrophysics Data System (ADS)
Amoedo, Simon; Thebaud, Edouard; Gschwendtner, Michael; White, David
2016-06-01
A parameter study was carried out on the design variables of a flexure bearing to be used in a Stirling engine with a fixed axial displacement and a fixed outer diameter. A design method was developed in order to assist identification of the optimum bearing configuration. This was achieved through a parameter study of the bearing carried out with ANSYS®. The parameters varied were the number and the width of the arms, the thickness of the bearing, the eccentricity, the size of the starting and ending holes, and the turn angle of the spiral. Comparison was made between the different designs in terms of axial and radial stiffness, the natural frequency, and the maximum induced stresses. Moreover, the Finite Element Analysis (FEA) was compared to theoretical results for a given design. The results led to a graphical design method which assists the selection of flexure bearing geometrical parameters based on pre-determined geometric and material constraints.
Facchinello, Yann; Brailovski, Vladimir; Petit, Yvan; Mac-Thiong, Jean-Marc
2014-11-01
The concept of a monolithic Ti-Ni spinal rod with variable flexural stiffness is proposed to reduce the risks associated with spinal fusion. The variable stiffness is conferred to the rod using the Joule-heating local annealing technique. The annealing temperature and the mechanical properties' distributions resulted from this thermal treatment are numerically modeled and experimentally measured. To illustrate the possible applications of such a modeling approach, two case studies are presented: (a) optimization of the Joule-heating strategy to reduce annealing time, and (b) modulation of the rod's overall flexural stiffness using partial annealing. A numerical model of a human spine coupled with the model of the variable flexural stiffness spinal rod developed in this work can ultimately be used to maximize the stabilization capability of spinal instrumentation, while simultaneously decreasing the risks associated with spinal fusion. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.
The nonlinear flexural response of a whole teleost fish: Contribution of scales and skin.
Szewciw, Lawrence; Zhu, Deju; Barthelat, Francois
2017-12-01
The scaled skin of fish is an intricate system that provides mechanical protection against hard and sharp puncture, while maintaining the high flexural compliance required for unhindered locomotion. This unusual combination of local hardness and global compliance makes fish skin an interesting model for bioinspired protective systems. In this work we investigate the flexural response of whole teleost fish, and how scales may affect global flexural stiffness. A bending moment is imposed on the entire body of a striped bass (Morone saxatilis). Imaging is used to measure local curvature, to generate moment-curvature curves as function of position along the entire axis of the fish. We find that the flexural stiffness is the highest in the thick middle portion of the fish, and lowest in the caudal and rostral ends. The flexural response is nonlinear, with an initial soft response followed by significant stiffening at larger flexural deformations. Low flexural stiffness at low curvatures promotes efficient swimming, while higher stiffness at high curvatures enables a possible tendon effect, where the mechanical energy at the end of a stroke is stored in the form of strain energy in the fish skin. To assess the contribution of the scales to stiffening we performed flexural tests with and without scales, following a careful protocol to take in account tissue degradation and the effects of temperature. Our findings suggest that scales do not substantially increase the whole body flexural stiffness of teleost fish over ranges of deformations which are typical of swimming and maneuvering. Teleost scales are thin and relatively flexible, so they can accommodate large flexural deformations. This finding is in contrast to the bulkier ganoid scales which were shown in previous reports to have a profound impact of global flexural deformations and swimming in fish like gar or Polypterus. Copyright © 2017 Elsevier Ltd. All rights reserved.
Functions of fish skin: flexural stiffness and steady swimming of longnose gar, Lepisosteus osseus
Long; Hale; Mchenry; Westneat
1996-01-01
The functions of fish skin during swimming remain enigmatic. Does skin stiffen the body and alter the propagation of the axial undulatory wave? To address this question, we measured the skin's in situ flexural stiffness and in vivo mechanical role in the longnose gar Lepisosteus osseus. To measure flexural stiffness, dead gar were gripped and bent in a device that measured applied bending moment (N m) and the resulting midline curvature (m-1). From these values, the flexural stiffness of the body (EI in N m2) was calculated before and after sequential alterations of skin structure. Cutting of the dermis between two caudal scale rows significantly reduced the flexural stiffness of the body and increased the neutral zone of curvature, a region of bending without detectable stiffness. Neither bending property was significantly altered by the removal of a caudal scale row. These alterations in skin structure were also made in live gar and the kinematics of steady swimming was measured before and after each treatment. Cutting of the dermis between two caudal scale rows, performed under anesthesia, changed the swimming kinematics of the fish: tailbeat frequency (Hz) and propulsive wave speed (body lengths per second, L s-1) decreased, while the depth (in L) of the trailing edge of the tail increased. The decreases in tailbeat frequency and wave speed are consistent with predictions of the theory of forced, harmonic vibrations; wave speed, if equated with resonance frequency, is proportional to the square root of a structure's stiffness. While it did not significantly reduce the body's flexural stiffness, surgical removal of a caudal scale row resulted in increased tailbeat amplitude and the relative total hydrodynamic power. In an attempt to understand the specific function of the scale row, we propose a model in which a scale row resists medio-lateral force applied by a single myomere, thus functioning to enhance mechanical advantage for bending. Finally, surgical removal of a precaudal scale row did not significantly alter any of the kinematic variables. This lack of effect is associated with a lower midline curvature of the precaudal region during swimming compared with that of the caudal region. Overall, these results demonstrate a causal relationship between skin, the passive flexural stiffness it imparts to the body and the influence of body stiffness on the undulatory wave speed and cycle frequency at which gar choose to swim.
NASA Astrophysics Data System (ADS)
Tretyakov, A.; Tkalenko, I.; Wald, F.; Novak, J.; Stefan, R.; Kohoutková, A.
2017-09-01
The recent development in technology of production and transportation of steel fibre-reinforced concrete enables its utilization in composite steel-concrete structures. This work is a part of a project which focuses on development of mechanical behaviour of circular hollow section (CHS) composite steel and fibre-concrete (SFRC) columns at elevate temperature. Research includes two levels of accuracy/complexity, allowing simplified or advanced approach for design that follows upcoming changes in European standard for composite member design in fire EN1994-1-2 [1]. One part is dedicated to determination and description of flexural stiffness of the SFRC CHS columns. To determinate flexural stiffness were prepared series of pure bending tests at elevated and ambient temperature. Presented paper focuses on the results of the tests and determination of flexural stiffness at ambient temperature. Obtained outputs were compared to data of existing studies about concrete-filled tube members with plain concrete and values analytically calculated according to the existing European standard EN1994-1-1 [2].
Flexural Behavior of Aluminum Honeycomb Core Sandwich Structure
NASA Astrophysics Data System (ADS)
Matta, Vidyasagar; Kumar, J. Suresh; Venkataraviteja, Duddu; Reddy, Guggulla Bharath Kumar
2017-05-01
This project is concerned with the fabrication and flexural testing of aluminium honey comb sandwich structure which is a special case of composite materials that is fabricated by attaching two thin but stiff skins to a light weight but thick core. The core material is normally low density material but its high thickness provide the sandwich composite with high bonding stiffness. Honeycomb core are classified into two types based on the materials and structures. Hexagonal shape has a unique properties i.e has more bonding strength and less formation time based on the cell size and sheet thickness. Sandwich structure exhibit different properties such as high load bearing capacity at low weight and has excellent thermal insulation. By considering the above properties it has tendency to minimize the structural problem. So honey comb sandwich structure is choosed. The core structure has a different applications such as aircraft, ship interiors, construction industries. As there is no proper research on strength characteristics of sandwich structure. So, we use light weight material to desire the strength. There are different parameters involved in this structure i.e cell size, sheet thickness and core height. In this project we considered 3 level of comparison among the 3 different parameters cell size of 4, 6 and 8 mm, sheet thickness of 0.3, 0.5 and 0.7 mm, and core height of 20,25 and 30 mm. In order to reduce the number of experiment we use taguchi design of experiment, and we select the L8 orthogonal array is the best array for this type of situation, which clearly identifies the parameters by independent of material weight to support this we add the minitab software, to identify the main effective plots and regression equation which involves the individual response and corresponding parameters. Aluminium material is used for the fabrication of Honeycomb sandwich structure among the various grades of aluminium we consider the AL6061 which is light weight material and has more strength. By the power press used as forming method we fabricate the honey comb core and stacking the sheets with adhesive as epoxy resin or laser beam welding and sandwich structure will form with two face sheets. Then the specimen is taken to be tested to know the flexural behaviour by the flexural test as 3 point and 4 pont bend test. After testing of two different tests then we get the force vs displacement curve by this we can know the maximum force and by loading configurations and its displacement or deflection then we can calculate flexural stiffness and core shear modulus by the variation of three parameters. Our ultimate aim is to achieve maximum strength by minimum weight.
Flexural wave suppression by an elastic metamaterial beam with zero bending stiffness
NASA Astrophysics Data System (ADS)
Zhang, Yong Yan; Wu, Jiu Hui; Hu, Guang Zhong; Wang, Yu Chun
2017-04-01
In this paper, different from Bragg scattering or local resonance mechanisms, a novel mechanism of an ultra-low-frequency broadband for flexural waves propagating in a one-dimensional elastic metamaterial beam with zero bending stiffness is proposed, which consists of periodic hinge-linked blocks. The dispersion relationship of this kind of metamaterial beam is derived and analyzed, from which we find that these hinge-linked blocks can produce the zero bending stiffness. Thus, the flexural waves within the metamaterial beam can be suppressed, and an ultra-low-frequency wide band-gap is formed in which the first branch is generated by the zero bending spring and the second branch by the negative velocity of the metamaterial beam. Numerical results show that the elastic metamaterial beams with zero bending stiffness can indeed generate an ultra-low-frequency wide band gap even starting from almost zero frequency, such as from 0 Hz to 525 Hz in our structure. Therefore, the puzzle of realizing an ultra-low-frequency broadband of flexural waves may have been better solved, which could be applied in controlling ultra-low-frequency elastic waves in engineering.
Lithospheric bending at subduction zones based on depth soundings and satellite gravity
NASA Technical Reports Server (NTRS)
Levitt, Daniel A.; Sandwell, David T.
1995-01-01
A global study of trench flexure was performed by simultaneously modeling 117 bathymetric profiles (original depth soundings) and satellite-derived gravity profiles. A thin, elastic plate flexure model was fit to each bathymetry/gravity profile by minimization of the L(sub 1) norm. The six model parameters were regional depth, regional gravity, trench axis location, flexural wavelength, flexural amplitude, and lithospheric density. A regional tilt parameter was not required after correcting for age-related trend using a new high-resolution age map. Estimates of the density parameter confirm that most outer rises are uncompensated. We find that flexural wavelength is not an accurate estimate of plate thickness because of the high curvatures observed at a majority of trenches. As in previous studies, we find that the gravity data favor a longer-wavelength flexure than the bathymetry data. A joint topography-gravity modeling scheme and fit criteria are used to limit acceptable parameter values to models for which topography and gravity yield consistent results. Even after the elastic thicknesses are converted to mechanical thicknesses using the yield strength envelope model, residual scatter obscures the systematic increase of mechanical thickness with age; perhaps this reflects the combination of uncertainties inherent in estimating flexural wavelength, such as extreme inelastic bending and accumulated thermoelastic stress. The bending moment needed to support the trench and outer rise topography increases by a factor of 10 as lithospheric age increases from 20 to 150 Ma; this reflects the increase in saturation bending moment that the lithosphere can maintain. Using a stiff, dry-olivine rheology, we find that the lithosphere of the GDH1 thermal model (Stein and Stein, 1992) is too hot and thin to maintain the observed bending moments. Moreover, the regional depth seaward of the oldest trenches (approximately 150 Ma) exceeds the GDH1 model depths by about 400 m.
NASA Astrophysics Data System (ADS)
Singh, Ranjan Kumar; Rinawa, Moti Lal
2018-04-01
The residual stresses arising in fiber-reinforced laminates during their curing in closed molds lead to changes in the composites after their removal from the molds and cooling. One of these dimensional changes of angle sections is called springback. The parameters such as lay-up, stacking sequence, material system, cure temperature, thickness etc play important role in it. In present work, it is attempted to optimize lay-up and stacking sequence for maximization of flexural stiffness and minimization of springback angle. The search algorithms are employed to obtain best sequence through repair strategy such as swap. A new search algorithm, termed as lay-up search algorithm (LSA) is also proposed, which is an extension of permutation search algorithm (PSA). The efficacy of PSA and LSA is tested on the laminates with a range of lay-ups. A computer code is developed on MATLAB implementing the above schemes. Also, the strategies for multi objective optimization using search algorithms are suggested and tested.
On the identification of cohesive parameters for printed metal-polymer interfaces
NASA Astrophysics Data System (ADS)
Heinrich, Felix; Langner, Hauke H.; Lammering, Rolf
2017-05-01
The mechanical behavior of printed electronics on fiber reinforced composites is investigated. A methodology based on cohesive zone models is employed, considering interfacial strengths, stiffnesses and critical strain energy release rates. A double cantilever beam test and an end notched flexure test are carried out to experimentally determine critical strain energy release rates under fracture modes I and II. Numerical simulations are performed in Abaqus 6.13 to model both tests. Applying the simulations, an inverse parameter identification is run to determine the full set of cohesive parameters.
Kennedy, Emily B; Hsiung, Bor-Kai; Swift, Nathan B; Tan, Kwek-Tze
2017-11-01
Hedgehogs are agile climbers, scaling trees and plants to heights exceeding 10m while foraging insects. Hedgehog spines (a.k.a. quills) provide fall protection by absorbing shock and could offer insights for the design of lightweight, material-efficient, impact-resistant structures. There has been some study of flexural properties of hedgehog spines, but an understanding of how this keratinous biological material is affected by various temperature and relative humidity treatments, or how spine color (multicolored vs. white) affects mechanics, is lacking. To bridge this gap in the literature, we use three-point bending to analyze the effect of temperature, humidity, spine color, and their interactions on flexural strength and modulus of hedgehog spines. We also compare specific strength and stiffness of hedgehog spines to conventional engineered materials. We find hedgehog spine flexural properties can be finely tuned by modifying environmental conditioning parameters. White spines tend to be stronger and stiffer than multicolored spines. Finally, for most temperature and humidity conditioning parameters, hedgehog spines are ounce for ounce stronger than 201 stainless steel rods of the same diameter but as pliable as styrene rods with a slightly larger diameter. This unique combination of strength and elasticity makes hedgehog spines exemplary shock absorbers, and a suitable reference model for biomimicry. Copyright © 2017 Elsevier Ltd. All rights reserved.
Influence of Tension Stiffening on the Flexural Stiffness of Reinforced Concrete Circular Sections
Morelli, Francesco; Amico, Cosimo; Salvatore, Walter; Squeglia, Nunziante; Stacul, Stefano
2017-01-01
Within this paper, the assessment of tension stiffening effects on a reinforced concrete element with circular section subjected to axial and bending loads is presented. To this purpose, an enhancement of an analytical model already present within the actual technical literature is proposed. The accuracy of the enhanced method is assessed by comparing the experimental results carried out in past research and the numerical ones obtained by the model. Finally, a parametric study is executed in order to study the influence of axial compressive force on the flexural stiffness of reinforced concrete elements that are characterized by a circular section, comparing the secant stiffness evaluated at yielding and at maximum resistance, considering and not considering the effects of tension stiffness. PMID:28773028
Influence of Tension Stiffening on the Flexural Stiffness of Reinforced Concrete Circular Sections.
Morelli, Francesco; Amico, Cosimo; Salvatore, Walter; Squeglia, Nunziante; Stacul, Stefano
2017-06-18
Within this paper, the assessment of tension stiffening effects on a reinforced concrete element with the circular sections subjected to axial and bending loads is presented. To this purpose, an enhancement of an analytical model already present within the actual technical literature is proposed. The accuracy of the enhanced method is assessed by comparing the experimental results carried out in past research and the numerical ones obtained by the model. Finally, a parametric study is executed in order to study the influence of axial compressive force on the flexural stiffness of reinforced concrete elements that are characterized by a circular section, comparing the secant stiffness evaluated at yielding and at maximum resistance, considering and not considering the effects of tension stiffness.
Simulating flight boundary conditions for orbiter payload modal survey
NASA Technical Reports Server (NTRS)
Chung, Y. T.; Sernaker, M. L.; Peebles, J. H.
1993-01-01
An approach to simulate the characteristics of the payload/orbiter interfaces for the payload modal survey was developed. The flexure designed for this approach is required to provide adequate stiffness separation in the free and constrained interface degrees of freedom to closely resemble the flight boundary condition. Payloads will behave linearly and demonstrate similar modal effective mass distribution and load path as the flight if the flexure fixture is used for the payload modal survey. The potential non-linearities caused by the trunnion slippage during the conventional fixed base modal survey may be eliminated. Consequently, the effort to correlate the test and analysis models can be significantly reduced. An example is given to illustrate the selection and the sensitivity of the flexure stiffness. The advantages of using flexure fixtures for the modal survey and for the analytical model verification are also demonstrated.
NASA Astrophysics Data System (ADS)
Attar, M.; Karrech, A.; Regenauer-Lieb, K.
2014-05-01
The free vibration of a shear deformable beam with multiple open edge cracks is studied using a lattice spring model (LSM). The beam is supported by a so-called two-parameter elastic foundation, where normal and shear foundation stiffnesses are considered. Through application of Timoshenko beam theory, the effects of transverse shear deformation and rotary inertia are taken into account. In the LSM, the beam is discretised into a one-dimensional assembly of segments interacting via rotational and shear springs. These springs represent the flexural and shear stiffnesses of the beam. The supporting action of the elastic foundation is described also by means of normal and shear springs acting on the centres of the segments. The relationship between stiffnesses of the springs and the elastic properties of the one-dimensional structure are identified by comparing the homogenised equations of motion of the discrete system and Timoshenko beam theory.
NASA Astrophysics Data System (ADS)
Jiang, Yao; Li, Tie-Min; Wang, Li-Ping
2015-09-01
This paper investigates the stiffness modeling of compliant parallel mechanism (CPM) based on the matrix method. First, the general compliance matrix of a serial flexure chain is derived. The stiffness modeling of CPMs is next discussed in detail, considering the relative positions of the applied load and the selected displacement output point. The derived stiffness models have simple and explicit forms, and the input, output, and coupling stiffness matrices of the CPM can easily be obtained. The proposed analytical model is applied to the stiffness modeling and performance analysis of an XY parallel compliant stage with input and output decoupling characteristics. Then, the key geometrical parameters of the stage are optimized to obtain the minimum input decoupling degree. Finally, a prototype of the compliant stage is developed and its input axial stiffness, coupling characteristics, positioning resolution, and circular contouring performance are tested. The results demonstrate the excellent performance of the compliant stage and verify the effectiveness of the proposed theoretical model. The general stiffness models provided in this paper will be helpful for performance analysis, especially in determining coupling characteristics, and the structure optimization of the CPM.
Highly damped kinematic coupling for precision instruments
Hale, Layton C.; Jensen, Steven A.
2001-01-01
A highly damped kinematic coupling for precision instruments. The kinematic coupling provides support while causing essentially no influence to its nature shape, with such influences coming, for example, from manufacturing tolerances, temperature changes, or ground motion. The coupling uses three ball-cone constraints, each combined with a released flexural degree of freedom. This arrangement enables a gain of higher load capacity and stiffness, but can also significantly reduce the friction level in proportion to the ball radius divided by the distance between the ball and the hinge axis. The blade flexures reduces somewhat the stiffness of the coupling and provides an ideal location to apply constrained-layer damping which is accomplished by attaching a viscoelastic layer and a constraining layer on opposite sides of each of the blade flexures. The three identical ball-cone flexures provide a damped coupling mechanism to kinematically support the projection optics system of the extreme ultraviolet lithography (EUVL) system, or other load-sensitive apparatus.
Free in-plane vibration of circular arches.
NASA Technical Reports Server (NTRS)
Veletsos, A. S.; Austin, W. J.; Lopes Pereira, C. A.; Wung, S.-J.
1972-01-01
Numerical data are presented for the natural frequencies and modes of vibration of hinged and fixed, uniform, circular arches vibrating in their own plane, and the effects of the various parameters affecting the response are analyzed. It is shown that the vibrational modes may be almost purely flexural, or almost purely extensional, or the extensional and flexural actions may be strongly coupled. The conditions of occurrence of each type of behavior are defined, and simple approximate formulas are derived; using these formulas, the free vibrational characteristics of arches may be estimated to a satisfactory degree of accuracy for most practical applications. The approach used to derive the approximate formulas may also be applied to arches having other boundary conditions, shapes, or distributions of stiffness and mass.
Intrinsic low pass filtering improves signal-to-noise ratio in critical-point flexure biosensors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jain, Ankit; Alam, Muhammad Ashraful, E-mail: alam@purdue.edu
2014-08-25
A flexure biosensor consists of a suspended beam and a fixed bottom electrode. The adsorption of the target biomolecules on the beam changes its stiffness and results in change of beam's deflection. It is now well established that the sensitivity of sensor is maximized close to the pull-in instability point, where effective stiffness of the beam vanishes. The question: “Do the signal-to-noise ratio (SNR) and the limit-of-detection (LOD) also improve close to the instability point?”, however remains unanswered. In this article, we systematically analyze the noise response to evaluate SNR and establish LOD of critical-point flexure sensors. We find thatmore » a flexure sensor acts like an effective low pass filter close to the instability point due to its relatively small resonance frequency, and rejects high frequency noise, leading to improved SNR and LOD. We believe that our conclusions should establish the uniqueness and the technological relevance of critical-point biosensors.« less
Design of responsive materials using topologically interlocked elements
NASA Astrophysics Data System (ADS)
Molotnikov, A.; Gerbrand, R.; Qi, Y.; Simon, G. P.; Estrin, Y.
2015-02-01
In this work we present a novel approach to designing responsive structures by segmentation of monolithic plates into an assembly of topologically interlocked building blocks. The particular example considered is an assembly of interlocking osteomorphic blocks. The results of this study demonstrate that the constraining force, which is required to hold the blocks together, can be viewed as a design parameter that governs the bending stiffness and the load bearing capacity of the segmented structure. In the case where the constraining forces are provided laterally using an external frame, the maximum load the assembly can sustain and its stiffness increase linearly with the magnitude of the lateral load applied. Furthermore, we show that the segmented plate with integrated shape memory wires employed as tensioning cables can act as a smart structure that changes its flexural stiffness and load bearing capacity in response to external stimuli, such as heat generated by the switching on and off an electric current.
Ma, Jun; Chen, Si-Lu; Kamaldin, Nazir; Teo, Chek Sing; Tay, Arthur; Mamun, Abdullah Al; Tan, Kok Kiong
2017-11-01
The biaxial gantry is widely used in many industrial processes that require high precision Cartesian motion. The conventional rigid-link version suffers from breaking down of joints if any de-synchronization between the two carriages occurs. To prevent above potential risk, a flexure-linked biaxial gantry is designed to allow a small rotation angle of the cross-arm. Nevertheless, the chattering of control signals and inappropriate design of the flexure joint will possibly induce resonant modes of the end-effector. Thus, in this work, the design requirements in terms of tracking accuracy, biaxial synchronization, and resonant mode suppression are achieved by integrated optimization of the stiffness of flexures and PID controller parameters for a class of point-to-point reference trajectories with same dynamics but different steps. From here, an H 2 optimization problem with defined constraints is formulated, and an efficient iterative solver is proposed by hybridizing direct computation of constrained projection gradient and line search of optimal step. Comparative experimental results obtained on the testbed are presented to verify the effectiveness of the proposed method. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.
Goodrich, Katherine R; Ortiz, Luis A; Coughlin, David J
2016-11-01
Deciduous woody species invest considerable resources in the growth of new foliage and distal stems. This new growth is at risk for mechanical damage from high winds and storms. Pawpaw has large leaves borne distally on thin twigs. Following a storm, pawpaw branches sometimes exhibit a persistent "flipped" orientation, slowly returning upright over 24 h. We investigated biomechanical properties of pawpaw twigs, comparing them to co-occurring species with similarly high leaf areas and loads, which do not exhibit this "flipping". Our goal was to determine biomechanical and structural properties in these species and how variation in form might relate to functional differences. We measured flexural stiffness, torsional stiffness, and viscoelastic creep in pawpaw and co-occurring trees Liriodendron tulipifera and Carya cordiformis. We also recorded twig/foliage reconfiguration in high winds. We stained thin cross sections of distal twigs and recorded images using fluorescent light microscopy. Flexural and torsional stiffness increased with twig radius in pawpaw and tulip tree, although torsional stiffness increased more slowly in pawpaw. Pawpaw had a high ratio of flexural to torsional stiffness (EI/GJ) across a range of twig radii and significant viscoelastic creep compared with the other species. Biomechanical data showed that pawpaw twigs were "twistier" than the comparison species, which were shown previously to alleviate drag-induced damage by reorienting petioles and leaves. Pawpaw has an unusual strategy of low torsional stiffness in twigs, allowing for reorientation of the entire distal appendage, likely minimizing drag-induced damage in storms. © 2016 Botanical Society of America.
NASA Astrophysics Data System (ADS)
Mohamed, Omar Ahmed; Masood, Syed Hasan; Bhowmik, Jahar Lal
2017-03-01
The resistance of polymeric materials to time-dependent plastic deformation is an important requirement of the fused deposition modeling (FDM) design process, its processed products, and their application for long-term loading, durability, and reliability. The creep performance of the material and part processed by FDM is the fundamental criterion for many applications with strict dimensional stability requirements, including medical implants, electrical and electronic products, and various automotive applications. Herein, the effect of FDM fabrication conditions on the flexural creep stiffness behavior of polycarbonate-acrylonitrile-butadiene-styrene processed parts was investigated. A relatively new class of experimental design called "definitive screening design" was adopted for this investigation. The effects of process variables on flexural creep stiffness behavior were monitored, and the best suited quadratic polynomial model with high coefficient of determination ( R 2) value was developed. This study highlights the value of response surface definitive screening design in optimizing properties for the products and materials, and it demonstrates its role and potential application in material processing and additive manufacturing.
Computational methods for the identification of spatially varying stiffness and damping in beams
NASA Technical Reports Server (NTRS)
Banks, H. T.; Rosen, I. G.
1986-01-01
A numerical approximation scheme for the estimation of functional parameters in Euler-Bernoulli models for the transverse vibration of flexible beams with tip bodies is developed. The method permits the identification of spatially varying flexural stiffness and Voigt-Kelvin viscoelastic damping coefficients which appear in the hybrid system of ordinary and partial differential equations and boundary conditions describing the dynamics of such structures. An inverse problem is formulated as a least squares fit to data subject to constraints in the form of a vector system of abstract first order evolution equations. Spline-based finite element approximations are used to finite dimensionalize the problem. Theoretical convergence results are given and numerical studies carried out on both conventional (serial) and vector computers are discussed.
Simon, David D; Andrews, Sharon M; Robinson-Zeigler, Rebecca; Valdes, Thelma; Woods, Terry O
2018-02-01
Current mechanical testing of surgical mesh focuses primarily on tensile properties even though implanted devices are not subjected to pure tensile loads. Our objective was to determine the flexural (bending) properties of surgical mesh and determine if they correlate with mesh tensile properties. The flexural rigidity values of 11 different surgical mesh designs were determined along three textile directions (machine, cross-machine, and 45° to machine; n = 5 for each) using ASTM D1388-14 while tracking surface orientation. Tensile testing was also performed on the same specimens using ASTM D882-12. Linear regressions were performed to compare mesh flexural rigidity to mesh thickness, areal mass density, filament diameter, ultimate tensile strength, and maximum extension. Of 33 mesh specimen groups, 30 had significant differences in flexural rigidity values when comparing surface orientations (top and bottom). Flexural rigidity and mesh tensile properties also varied with textile direction (machine and cross-machine). There was no strong correlation between the flexural and tensile properties, with mesh thickness having the best overall correlation with flexural rigidity. Currently, surface orientation is not indicated on marketed surgical mesh, and a single mesh may behave differently depending on the direction of loading. The lack of correlation between flexural stiffness and tensile properties indicates the need to examine mesh bending stiffness to provide a more comprehensive understanding of surgical mesh mechanical behaviors. Further investigation is needed to determine if these flexural properties result in the surgical mesh behaving mechanically different depending on implantation direction. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 854-862, 2018. © 2017 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Fredette, Luke; Singh, Rajendra
2017-02-01
A spectral element approach is proposed to determine the multi-axis dynamic stiffness terms of elastomeric isolators with fractional damping over a broad range of frequencies. The dynamic properties of a class of cylindrical isolators are modeled by using the continuous system theory in terms of homogeneous rods or Timoshenko beams. The transfer matrix type dynamic stiffness expressions are developed from exact harmonic solutions given translational or rotational displacement excitations. Broadband dynamic stiffness magnitudes (say up to 5 kHz) are computationally verified for axial, torsional, shear, flexural, and coupled stiffness terms using a finite element model. Some discrepancies are found between finite element and spectral element models for the axial and flexural motions, illustrating certain limitations of each method. Experimental validation is provided for an isolator with two cylindrical elements (that work primarily in the shear mode) using dynamic measurements, as reported in the prior literature, up to 600 Hz. Superiority of the fractional damping formulation over structural or viscous damping models is illustrated via experimental validation. Finally, the strengths and limitations of the spectral element approach are briefly discussed.
Evaluation of mechanical and thermal properties of commonly used denture base resins.
Phoenix, Rodney D; Mansueto, Michael A; Ackerman, Neal A; Jones, Robert E
2004-03-01
The purpose of this investigation was to evaluate and compare the mechanical and thermal properties of 6 commonly used polymethyl methacrylate denture base resins. Sorption, solubility, color stability, adaptation, flexural stiffness, and hardness were assessed to determine compliance with ADA Specification No. 12. Thermal assessments were performed using differential scanning calorimetry and dynamic mechanical analysis. Results were assessed using statistical and observational analyses. All materials satisfied ADA requirements for sorption, solubility, and color stability. Adaptation testing indicated that microwave-activated systems provided better adaptation to associated casts than conventional heat-activated resins. According to flexural testing results, microwaveable resins were relatively stiff, while rubber-modified resins were more flexible. Differential scanning calorimetry indicated that microwave-activated systems were more completely polymerized than conventional heat-activated materials. The microwaveable resins displayed better adaptation, greater stiffness, and greater surface hardness than other denture base resins included in this investigation. Elastomeric toughening agents yielded decreased stiffness, decreased surface hardness, and decreased glass transition temperatures.
Gramazio, Federico; Lorenzoni, Matteo; Pérez-Murano, Francesc; Rull Trinidad, Enrique; Staufer, Urs; Fraxedas, Jordi
2017-01-01
We present a combined theoretical and experimental study of the dependence of resonant higher harmonics of rectangular cantilevers of an atomic force microscope (AFM) as a function of relevant parameters such as the cantilever force constant, tip radius and free oscillation amplitude as well as the stiffness of the sample's surface. The simulations reveal a universal functional dependence of the amplitude of the 6th harmonic (in resonance with the 2nd flexural mode) on these parameters, which can be expressed in terms of a gun-shaped function. This analytical expression can be regarded as a practical tool for extracting qualitative information from AFM measurements and it can be extended to any resonant harmonics. The experiments confirm the predicted dependence in the explored 3-45 N/m force constant range and 2-345 GPa sample's stiffness range. For force constants around 25 N/m, the amplitude of the 6th harmonic exhibits the largest sensitivity for ultrasharp tips (tip radius below 10 nm) and polymers (Young's modulus below 20 GPa).
Use of asymptotic methods in vibration analysis
NASA Technical Reports Server (NTRS)
Ashley, H.
1978-01-01
The derivation of dynamic differential equations, suitable for studying the vibrations of rotating, curved, slender structures was examined, and the Hamiltonian procedure was advocated for this purpose. Various reductions of the full system are displayed, which govern the vibrating troposkien when various order of magnitude restrictions are placed on important parameters. Possible advantages of the WKB asymptotic method for solving these classes of problems are discussed. A special case of this method is used illustratively to calculate eigenvalues and eigenfunctions for a flat turbine blade with small flexural stiffness.
Buckling Behavior of Long Anisotropic Plates Subjected to Fully Restrained Thermal Expansion
NASA Technical Reports Server (NTRS)
Nemeth, Michael P.
2003-01-01
An approach for synthesizing buckling results and behavior for thin, balanced and unbalanced symmetric laminates that are subjected to uniform heating or cooling and which are fully-restrained against thermal expansion or contraction is presented. This approach uses a nondimensional analysis for infinitely long, flexurally anisotropic plates that are subjected to combined mechanical loads and is based on useful nondimensional parameters. In addition, stiffness-weighted laminate thermal-expansion parameters are derived and used to determine critical temperature changes in terms of physically intuitive mechanical buckling coefficients. The effects of membrane orthotropy and anisotropy are included. Many results are presented for some common laminates that are intended to facilitate a structural designer's transition to the use of the generic buckling design curves that are presented in the paper. Several generic buckling design curves are presented that provide physical insight into buckling response and provide useful design data. Examples are presented that demonstrate the use of generic design curves. The analysis approach and generic results indicate the effects and characteristics of laminate thermal expansion, membrane orthotropy and anisotropy, and flexural orthotropy and anisotropy in a very general, unifying manner.
Effect of electrospun nanofibers on flexural properties of fiberglass composites
NASA Astrophysics Data System (ADS)
White, Fatima T.
In the present study, sintered electrospun TEOS nanofibers were interleaved in S2 fiberglass woven fabric layers, and composite panels were fabricated using the heated vacuum assisted resin transfer molding (H-VARTM) process. Cured panels were water jet cut to obtain the flexural test coupons. Flexural coupons were then tested using ASTM D7264 standard. The mechanical properties such as flexural strength, ultimate flexural failure strains, flexural modulus, and fiber volume fraction were measured. The S-2 fiberglass composite with the sintered TEOS electrospun nanofibers displayed lower flexural stiffness and strength as compared to the composites that were fabricated using S-2 fiberglass composite without the TEOS electrospun nanofibers. The present study also indicated that the composites fabricated with sintered TEOS electrospun nanofibers have larger failure strains as compared to the ones that were fabricated without the presence of electrospun nanofibers. The study indicates that the nanoengineered composites have better energy absorbing mechanism under flexural loading as compared to conventional fiberglass composites without presence of nanofibers.
On a high-potential variable flexural stiffness device
NASA Astrophysics Data System (ADS)
Henke, Markus; Gerlach, Gerald
2013-05-01
There are great efforts in developing effective composite structures for lightweight constructions for nearly every field of engineering. This concerns for example aeronautics and spacecrafts, but also automotive industry and energy harvesting applications. Modern concepts of lightweight components try to make use of structures with properties which can be adjusted in a controllable was. However, classic composite materials can only slightly adapt to varying environmental conditions because most materials, like carbon or glass-fiber composites show properties which are time-constant and not changeable. This contribution describes the development, the potential and the limitations of novel smart, self-controlling structures which can change their mechanical properties - e.g. their flexural stiffness - by more then one order of magnitude. These structures use a multi-layer approach with a 10-layer stack of 0.75 mm thick polycarbonate. The set-up is analytically described and its mechanical behavior is predicted by finite element analysis done with ABAQUS. The layers are braided together by an array of shape memory alloy (SMA) wires, which can be activated independently. Depending on the temperature applied by the electrical current flowing through the wires and the corresponding contraction the wires can tightly clamp the layers so that they cannot slide against each other due to friction forces. In this case the multilayer acts as rigid beam with high stiffness. If the friction-induced shear stress is smaller than a certain threshold, then the layers can slide over each other and the multilayer becomes compliant under bending load. The friction forces between the layers and, hence, the stiffness of the beam is controlled by the electrical current through the wires. The more separate parts of SMA wires the structure has the larger is the number of steps of stiffness changes of the flexural beam.
High-temperature mechanical properties of a solid oxide fuel cell glass sealant in sintered forms
NASA Astrophysics Data System (ADS)
Chang, Hsiu-Tao; Lin, Chih-Kuang; Liu, Chien-Kuo; Wu, Szu-Han
High-temperature mechanical properties of a silicate-based glass sealant (GC-9) for planar solid oxide fuel cell have been studied in sintered forms. Ring-on-ring biaxial flexural tests are carried out at room temperature to 800 °C for the sintered GC-9 glass. The results are also compared with those in cast bulk forms. From the force-displacement curves, the glass transition temperature (T g) of the non-aged, sintered GC-9 glass is estimated to be between 700 °C and 750 °C, while that of the aged one is between 750 °C and 800 °C. Due to a crack healing effect of the residual glass at high temperature, the flexural strength of the sintered GC-9 glass at temperature of 650 °C to T g point is greater than that at room temperature. At temperature above T g, the flexural strength and stiffness are considerably reduced to a level lower than the room-temperature one. The sintered GC-9 glass with pores and crystalline phases has a flexural strength lower than the cast bulk one at temperature of 650 °C and below. Due to a greater extent of crystallization, the flexural strength and stiffness of the sintered GC-9 glass are greater than those of the cast bulk one at 700-800 °C.
Identification of the structure parameters using short-time non-stationary stochastic excitation
NASA Astrophysics Data System (ADS)
Jarczewska, Kamila; Koszela, Piotr; Śniady, PaweŁ; Korzec, Aleksandra
2011-07-01
In this paper, we propose an approach to the flexural stiffness or eigenvalue frequency identification of a linear structure using a non-stationary stochastic excitation process. The idea of the proposed approach lies within time domain input-output methods. The proposed method is based on transforming the dynamical problem into a static one by integrating the input and the output signals. The output signal is the structure reaction, i.e. structure displacements due to the short-time, irregular load of random type. The systems with single and multiple degrees of freedom, as well as continuous systems are considered.
Buckling Behavior of Long Anisotropic Plates Subjected to Elastically Restrained Thermal Expansion
NASA Technical Reports Server (NTRS)
Nemeth, Michael P.
2002-01-01
An approach for synthesizing buckling results for, and behavior of, thin balanced and unbalanced symmetric laminates that are subjected to uniform heating or cooling and elastically restrained against thermal expansion or contraction is presented. This approach uses a nondimensional analysis for infinitely long, flexurally anisotropic plates that are subjected to combined mechanical loads and is based on useful nondimensional parameters. In addition, stiffness-weighted laminate thermal-expansion parameters and compliance coefficients are derived that are used to determine critical temperatures in terms of physically intuitive mechanical-buckling coefficients. The effects of membrane orthotropy and membrane anisotropy are included in the general formulation. Many results are presented for some common laminates that are intended to facilitate a structural designer's transition to the use of generic buckling design curves. Several curves that illustrate the fundamental parameters used in the analysis are presented, for nine contemporary material systems, that provide physical insight into the buckling response in addition to providing useful design data. Examples are presented that demonstrate the use of generic design curves. The analysis approach and generic results indicate the effects and characteristics of elastically restrained laminate thermal expansion or contraction, membrane orthotropy and anisotropy, and flexural orthotropy and anisotropy in a very general and unifying manner.
A multiple functional connector for high-resolution optical satellites
NASA Astrophysics Data System (ADS)
She, Fengke; Zheng, Gangtie
2017-11-01
For earth observation satellites, perturbations from actuators, such as CMGs and momentum wheels, and thermal loadings from support structures often have significant impact on the image quality of an optical. Therefore, vibration isolators and thermal deformation releasing devices nowadays often become important parts of an image satellite. However, all these devices will weak the connection stiffness between the optical instrument and the satellite bus structure. This will cause concern of the attitude control system design for worrying about possible negative effect on the attitude control. Therefore, a connection design satisfying all three requirements is a challenge of advanced image satellites. Chinese scientists have proposed a large aperture high-resolution satellite for earth observation. To meet all these requirements and ensure image quality, specified multiple function connectors are designed to meet these challenging requirements, which are: isolating vibration, releasing thermal deformation and ensuring whole satellite dynamic properties [1]. In this paper, a parallel spring guide flexure is developed for both vibration isolation and thermal deformation releasing. The stiffness of the flexure is designed to meet the vibration isolation requirement. To attenuate vibration, and more importantly to satisfy the stability requirement of the attitude control system, metal damping, which has many merits for space applications, are applied in this connecter to provide a high damping ratio and nonlinear stiffness. The capability of the connecter for vibration isolation and attenuation is validated through numerical simulation and experiments. Connecter parameter optimization is also conducted to meet both requirements of thermal deformation releasing and attitude control. Analysis results show that the in-orbit attitude control requirement is satisfied while the thermal releasing performance is optimized. The design methods and analysis results are also provided in the present paper.
Buckling Behavior of Long Anisotropic Plates Subjected to Fully Restrained Thermal Expansion
NASA Technical Reports Server (NTRS)
Nemeth, Michael P.
2001-01-01
An approach for synthesizing buckling results and behavior for thin balanced and unbalanced symmetric laminates that are subjected to uniform heating or cooling and fully restrained against thermal expansion or contraction is presented. This approach uses a nondimensional analysis for infinitely long, flexurally anisotropic plates that are subjected to combined mechanical loads and is based on useful nondimensional parameters. In addition, stiffness-weighted laminate thermal-expansion parameters are derived that are used to determine critical temperatures in terms of physically intuitive mechanical buckling coefficients, and the effects of membrane orthotropy and membrane anisotropy are included. Many results are presented for some common laminates that are intended to facilitate a structural designer's transition to the use of the generic buckling design curves that are presented in the paper. Several generic buckling design curves are presented that provide physical insight into the buckling response in addition to providing useful design data. Examples are presented that demonstrate the use of the generic design curves. The analysis approach and generic results indicate the effects and characteristics of laminate thermal expansion, membrane orthotropy and anisotropy, and flexural orthotropy and anisotropy in a very general and unifying manner.
Flexural properties of three kinds of experimental fiber-reinforced composite posts.
Kim, Mi-Joo; Jung, Won-Chang; Oh, Seunghan; Hattori, Masayuki; Yoshinari, Masao; Kawada, Eiji; Oda, Yutaka; Bae, Ji-Myung
2011-01-01
The aim of this study was to estimate the flexural properties of three kinds of experimental fiber-reinforced composite (FRC) posts and to evaluate their potential use as posts. Experimental FRC posts were fabricated with glass, aramid, and UHMWP fibers. Commercial FRC posts were used for comparison. A three-point bending test was performed at a crosshead speed of 1 mm/min. Experimental glass fiber posts showed significantly higher flexural strengths and moduli than aramid and UHMWP posts. Experimental UHMWP posts demonstrated superior toughness to the commercial posts. The glass fiber posts displayed stiff, strong and brittle features, while the UHMWP posts were flexible, weak and ductile. The flexural properties of the aramid posts fell between those of the glass and UHMWP posts. In conclusion, the glass fiber posts proved excellent in flexural strengths and moduli. However, the superior toughness of UHMWP fibers suggests the possibility of their use as posts in combination with glass fibers.
Yong, Y K; Moheimani, S O R; Kenton, B J; Leang, K K
2012-12-01
Recent interest in high-speed scanning probe microscopy for high-throughput applications including video-rate atomic force microscopy and probe-based nanofabrication has sparked attention on the development of high-bandwidth flexure-guided nanopositioning systems (nanopositioners). Such nanopositioners are designed to move samples with sub-nanometer resolution with positioning bandwidth in the kilohertz range. State-of-the-art designs incorporate uniquely designed flexure mechanisms driven by compact and stiff piezoelectric actuators. This paper surveys key advances in mechanical design and control of dynamic effects and nonlinearities, in the context of high-speed nanopositioning. Future challenges and research topics are also discussed.
Characterization of flexure hinges for the French watt balance experiment
NASA Astrophysics Data System (ADS)
Pinot, Patrick; Genevès, Gérard
2014-08-01
In the French watt balance experiment, the translation and rotation functions must have no backlash, no friction, nor the need for lubricants. In addition errors in position and movement must be below 100 nm. Flexure hinges can meet all of these criteria. Different materials, profile shapes and machining techniques have been studied. The flexure pivots have been characterized using three techniques: 1) an optical microscope and, if necessary, a SEM to observe the surface inhomogeneities; 2) a mass comparator to determine the bending stiffness of unloaded pivots; 3) a loaded beam oscillating freely under vacuum to study the dynamic behavior of loaded pivots.
Effect of skull flexural properties on brain response during dynamic head loading - biomed 2013.
Harrigan, T P; Roberts, J C; Ward, E E; Carneal, C M; Merkle, A C
2013-01-01
The skull-brain complex is typically modeled as an integrated structure, similar to a fluid-filled shell. Under dynamic loads, the interaction of the skull and the underlying brain, cerebrospinal fluid, and other tissue produces the pressure and strain histories that are the basis for many theories meant to describe the genesis of traumatic brain injury. In addition, local bone strains are of interest for predicting skull fracture in blunt trauma. However, the role of skull flexure in the intracranial pressure response to blunt trauma is complex. Since the relative time scales for pressure and flexural wave transmission across the skull are not easily separated, it is difficult to separate out the relative roles of the mechanical components in this system. This study uses a finite element model of the head, which is validated for pressure transmission to the brain, to assess the influence of skull table flexural stiffness on pressure in the brain and on strain within the skull. In a Human Head Finite Element Model, the skull component was modified by attaching shell elements to the inner and outer surfaces of the existing solid elements that modeled the skull. The shell elements were given the properties of bone, and the existing solid elements were decreased so that the overall stiffness along the surface of the skull was unchanged, but the skull table bending stiffness increased by a factor of 2.4. Blunt impact loads were applied to the frontal bone centrally, using LS-Dyna. The intracranial pressure predictions and the strain predictions in the skull were compared for models with and without surface shell elements, showing that the pressures in the mid-anterior and mid-posterior of the brain were very similar, but the strains in the skull under the loads and adjacent to the loads were decreased 15% with stiffer flexural properties. Pressure equilibration to nearly hydrostatic distributions occurred, indicating that the important frequency components for typical impact loading are lower than frequencies based on pressure wave propagation across the skull. This indicates that skull flexure has a local effect on intracranial pressures but that the integrated effect of a dome-like structure under load is a significant part of load transfer in the skull in blunt trauma.
Roy, Sandipan; Panda, Debojyoti; Khutia, Niloy; Chowdhury, Amit Roy
2014-01-01
The present study investigates the mechanical response of representative volume elements of porous Ti-6Al-4V alloy, to arrive at a desired range of pore geometries that would optimize the reduction in stiffness necessary for biocompatibility with the stress concentration arising around the pore periphery, under physiological loading conditions with respect to orthopedic hip implants. A comparative study of the two is performed with the aid of a newly defined optimizing parameter called pore efficiency that takes into consideration both the stiffness quantity and the stress localization around pores. To perform a detailed analysis of the response of the porous structure over the entire spectrum of loading conditions that a hip implant is subjected to in vivo, the mechanical responses of 3D finite element models of cubic and rectangular parallelepiped geometries, with porosities varying over a range of 10% to 60%, are simulated under representative compressive, flexural as well as combined loading conditions. The results that are obtained are used to suggest a range of pore diameters that lower the effective stiffness and modulus of the implant to around 60% of the stiffness and modulus of dense solid implants while keeping the stress levels within permissible limits. PMID:25400663
Precision tip-tilt-piston actuator that provides exact constraint
Hale, Layton C.
1999-01-01
A precision device which can precisely actuate three degrees of freedom of an optic mount, commonly referred to as tip, tilt, and piston. The device consists of three identical flexure mechanisms, an optic mount to be supported and positioned, a structure that supports the flexure mechanisms, and three commercially available linear actuators. The advantages of the precision device is in the arrangement of the constraints offered by the flexure mechanism and not in the particular design of the flexure mechanisms, as other types of mechanisms could be substituted. Each flexure mechanism constrains two degrees of freedom in the plane of the mechanisms and one direction is actuated. All other degrees of freedom are free to move within the range of flexure mechanisms. Typically, three flexure mechanisms are equally spaced in angle about to optic mount and arranged so that each actuated degree of freedom is perpendicular to the plane formed by the optic mount. This arrangement exactly constrains the optic mount and allows arbitrary actuated movement of the plane within the range of the flexure mechanisms. Each flexure mechanism provides a mechanical advantage, typically on the order of 5:1, between the commercially available actuator and the functional point on the optic mount. This improves resolution by the same ratio and stiffness by the square of the ratio.
Quasi-static analysis of foil journal bearings for a Brayton cycle turboalternator
NASA Technical Reports Server (NTRS)
Eshel, A.
1974-01-01
A quasi-static analysis is presented for foil journal bearings designed for a NASA Brayton Cycle Turboalternator. Included in the analysis are effects of 'slack' (due to flexural rigidity of the foil), of frictionally restrained extension of the foil-length in contact with cylindrical guides, of fluid inertia and compressibility, and of thermal expansion of rotor, foil and supporting structure. Comparisons are made with results of early experiments performed by Licht (1968, 1969) and recent data of Licht and Branger (1973). Variatons of film thickness, foil tension and bearing stiffness are presented graphically as functions of pertinent parameters for the case of operation in zero-gravity environment.
Welke, Bastian; Hurschler, Christof; Föller, Marie; Schwarze, Michael; Calliess, Tilman
2013-07-11
Techniques for the skeletal attachment of amputation-prostheses have been developed over recent decades. This type of attachment has only been performed on a small number of patients. It poses various potential advantages compared to conventional treatment with a socket, but is also associated with an increased risk of bone or implant-bone interface fracture in the case of a fall. We therefore investigated the bending stiffness and ultimate bending moment of such devices implanted in human and synthetic bones. Eight human specimens and 16 synthetic models of the proximal femora were implanted with lower extremity prostheses and eight human specimens and six synthetic humeri were implanted with upper extremity prostheses. They were dissected according to typical amputation levels and underwent loading in a material testing machine in a four-point bending setup. Bending stiffness, ultimate bending moment and fracture modes were determined in a load to failure experiment. Additionally, axial pull-out was performed on eight synthetic specimens of the lower extremity. Maximum bending moment of the synthetic femora was 160.6±27.5 Nm, the flexural rigidity of the synthetic femora was 189.0±22.6 Nm2. Maximum bending moment of the human femora was 100.4±38.5 Nm, and the flexural rigidity was 137.8±29.4 Nm2. The maximum bending moment of the six synthetic humeri was 104.9±19.0 Nm, and the flexural rigidity was 63.7±3.6 Nm2. For the human humeri the maximum bending moment was 36.7±11.0 Nm, and the flexural rigidity at was 43.7±10.5 Nm2. The maximum pull-out force for the eight synthetic femora was 3571±919 N. Significant differences were found between human and synthetic specimens of the lower and upper extremity regarding maximum bending moment, bending displacement and flexural rigidity. The results of this study are relevant with respect to previous finding regarding the load at the interfaces of osseointegrated prosthesis fixation devices and are crucial for the development of safety devices intended to protect the bone-implant interface from damaging loadings.
Stiffness and ultimate load of osseointegrated prosthesis fixations in the upper and lower extremity
2013-01-01
Background Techniques for the skeletal attachment of amputation-prostheses have been developed over recent decades. This type of attachment has only been performed on a small number of patients. It poses various potential advantages compared to conventional treatment with a socket, but is also associated with an increased risk of bone or implant-bone interface fracture in the case of a fall. We therefore investigated the bending stiffness and ultimate bending moment of such devices implanted in human and synthetic bones. Methods Eight human specimens and 16 synthetic models of the proximal femora were implanted with lower extremity prostheses and eight human specimens and six synthetic humeri were implanted with upper extremity prostheses. They were dissected according to typical amputation levels and underwent loading in a material testing machine in a four-point bending setup. Bending stiffness, ultimate bending moment and fracture modes were determined in a load to failure experiment. Additionally, axial pull-out was performed on eight synthetic specimens of the lower extremity. Results Maximum bending moment of the synthetic femora was 160.6±27.5 Nm, the flexural rigidity of the synthetic femora was 189.0±22.6 Nm2. Maximum bending moment of the human femora was 100.4±38.5 Nm, and the flexural rigidity was 137.8±29.4 Nm2. The maximum bending moment of the six synthetic humeri was 104.9±19.0 Nm, and the flexural rigidity was 63.7±3.6 Nm2. For the human humeri the maximum bending moment was 36.7±11.0 Nm, and the flexural rigidity at was 43.7±10.5 Nm2. The maximum pull-out force for the eight synthetic femora was 3571±919 N. Conclusion Significant differences were found between human and synthetic specimens of the lower and upper extremity regarding maximum bending moment, bending displacement and flexural rigidity. The results of this study are relevant with respect to previous finding regarding the load at the interfaces of osseointegrated prosthesis fixation devices and are crucial for the development of safety devices intended to protect the bone-implant interface from damaging loadings. PMID:23844992
NASA Astrophysics Data System (ADS)
Santoni, Andrea; Schoenwald, Stefan; Van Damme, Bart; Fausti, Patrizio
2017-07-01
Cross-laminated timber (CLT) is an engineered wood with good structural properties and it is also economically competitive with the traditional building construction materials. However, due to its low volume density combined with its high stiffness, it does not provide sufficient sound insulation, thus it is necessary to develop specific acoustic treatments in order to increase the noise reduction performance. The material's mechanical properties are required as input data to perform the vibro-acoustic analyses necessary during the design process. In this paper the elastic constants of a CLT plate are derived by fitting the real component of the experimental flexural wave velocity with Mindlin's dispersion relation for thick plates, neglecting the influence of the plate's size and boundary conditions. Furthermore, its apparent elastic and stiffness properties are derived from the same set of experimental data, for the plate considered to be thin. Under this latter assumption the orthotropic behaviour of an equivalent thin CLT plate is described by using an elliptic model and verified with experimental results.
NASA Astrophysics Data System (ADS)
Li, Zhen; Zhu, Yun; Li, Yueming
2018-05-01
The elastic wave bandgap is obviously affected by heat while considering thermal stress. Nevertheless, the flat band, occurring in the lowest flexural branch, has not yet been explained clearly. This study investigates the influence of thermal stress on a flexural wave bandgap in a two-dimensional three-component acoustic metamaterial. Simulation results demonstrate that the band structure shifts to a lower frequency range, and the vibration response appears at a larger amplitude due to the bending stiffness being softened by the compressive membrane force. In addition, the first flexural band reduces to zero frequency in the central Brillouin zone. By viewing the vibration modes of the proposed unit cell, it is found that the out-of-plane mode shape attenuates with increasing temperature, while the in-plane vibration modes are unaffected by thermal stress.
Barkley, Sarice S; Deng, Zhao; Gates, Richard S; Reitsma, Mark G; Cannara, Rachel J
2012-02-01
Two independent lateral-force calibration methods for the atomic force microscope (AFM)--the hammerhead (HH) technique and the diamagnetic lateral force calibrator (D-LFC)--are systematically compared and found to agree to within 5 % or less, but with precision limited to about 15 %, using four different tee-shaped HH reference probes. The limitations of each method, both of which offer independent yet feasible paths toward traceable accuracy, are discussed and investigated. We find that stiff cantilevers may produce inconsistent D-LFC values through the application of excessively high normal loads. In addition, D-LFC results vary when the method is implemented using different modes of AFM feedback control, constant height and constant force modes, where the latter is more consistent with the HH method and closer to typical experimental conditions. Specifically, for the D-LFC apparatus used here, calibration in constant height mode introduced errors up to 14 %. In constant force mode using a relatively stiff cantilever, we observed an ≈ 4 % systematic error per μN of applied load for loads ≤ 1 μN. The issue of excessive load typically emerges for cantilevers whose flexural spring constant is large compared with the normal spring constant of the D-LFC setup (such that relatively small cantilever flexural displacements produce relatively large loads). Overall, the HH method carries a larger uncertainty, which is dominated by uncertainty in measurement of the flexural spring constant of the HH cantilever as well as in the effective length dimension of the cantilever probe. The D-LFC method relies on fewer parameters and thus has fewer uncertainties associated with it. We thus show that it is the preferred method of the two, as long as care is taken to perform the calibration in constant force mode with low applied loads.
Graphite-reinforced bone cement
NASA Technical Reports Server (NTRS)
Knoell, A. C.
1976-01-01
Chopped graphite fibers added to surgical bone cement form bonding agent with mechanical properties closely matched to those of bone. Curing reaction produces less heat, resulting in reduced traumatization of body tissues. Stiffness is increased without affecting flexural strength.
Environmental Effects on Graphite-Epoxy Fatigue Properties
NASA Technical Reports Server (NTRS)
Sumsion, H. T.
1976-01-01
Effects of torsional and flexural fatigue on the long-time Integrity of advanced graphite-epoxy structural composites have been investigated. Torsional fatigue tests were run at stress ratios of R = 0 (zero to maximum, repeated) and R = -1 (zero mean stress) on unidirectional, angleply, and woven graphite fiber materials in air and water at room temperature and at 74 C. Flexural fatigue tests (four-point bending) with R = -1 were run in air and water at room temperature, and with R = 0 in air. Results show that, in torsional cycling, both water environment and higher test temperature contribute to significant degradation of torsional stiffness. The degradation of stiffness from torsional stress cycling was observed to be much greater with R = -1 than with simple R = 0 cycling. The effect of environment also is greater in the fully reversed cycling. Flexural fatigue results on +/- 30 deg material show a large fatigue effect, with fatigue limits of less than 50% and 30% of the static failure strength for specimens tested under stress ratios of R = 0 and R = -1, respectively. Compliance measurements indicate that the final failures are preceded by damage initiation and accumulation, which begins at about 1% of the specimen life.
On singular cases in the design derivative of Green's functional
NASA Technical Reports Server (NTRS)
Reiss, Robert
1987-01-01
The author's prior development of a general abstract representation for the design sensitivities of Green's functional for linear structural systems is extended to the case where the structural stiffness vanishes at an internal location. This situation often occurs in the optimal design of structures. Most optimality criteria require that optimally designed beams be statically determinate. For clamped-pinned beams, for example, this is possible only if the flexural stiffness vanishes at some intermediate location. The Green's function for such structures depends upon the stiffness and the location where it vanishes. A precise representation for Green's function's sensitivity to the location of vanishing stiffness is presented for beams and axisymmetric plates.
Influence of ethanol on stiffness, toughness, and ductility of femurs of rats.
Kusy, R P; Hirsch, P F; Peng, T C
1989-04-01
Recently, we reported that the ingestion of alcohol in rats reduced the mechanical strength of femurs. Our results showed that, as the dose exceeded 0.012 g of ethanol per gram of body weight, a significant (p less than 0.001) loss of "strength" occurred that was independent of sex according to the relationship, Strength (N) = 140.4 - 6003 dose (g/g). In the present effort, the same flexure tests were reevaluated to include the parameters of stiffness, toughness, and ductility. These latest results confirm that the femurs of rats fed an ethanol liquid diet for 4 weeks are not only weaker but also more compliant and less energy absorbing. Although the femurs of rats fed ethanol are more ductile, the bones are more prone to fracture in fatigue and impact circumstances as well as under simple loading situations. The rat may be an appropriate model to study the mechanisms that lead to the higher incidence of fractures in the alcoholic human.
Fin Ray Stiffness and Fin Morphology Control Ribbon-Fin-Based Propulsion.
Liu, Hanlin; Taylor, Bevan; Curet, Oscar M
2017-06-01
Ribbon-fin-based propulsion has rich locomotor capabilities that can enhance the mobility and performance of underwater vehicles navigating in complex environments. Bony fishes using this type of propulsion send one or multiple traveling waves along an elongated fin with the actuation of highly flexible rays that are interconnected by an elastic membrane. In this work, we study how the use of flexible rays and different morphology can affect the performance of ribbon-fin propulsion. We developed a physical model composed of 15 rays that are interconnected with an elastic membrane. We tested four different ray flexural stiffness and four aspect ratios. The robotic model was tested in a low-turbulence flume under two flow conditions ([Formula: see text] wavelength/s). In two experimental sets, we measured fin kinematics, net surge forces, and power consumption. Using these data, we perform a thrust and power analysis of the undulating fin. We present the thrust coefficient, power coefficient, and propulsive efficiency. We find that the thrust generation was linear with the enclosed area swept by the fin, and square of the relative velocity between the incoming flow and traveling wave. The thrust coefficient levels off around 0.5. In addition, for our parameter range, we find that the power consumption scales by the cube of the effective tangential velocity of the rays [Formula: see text] (A is the amplitude of the ray oscillating motion, and [Formula: see text] is the angular velocity). We show that a decay in stiffness decreases both thrust production and power consumption. However, for rays with high flexural stiffness, the difference in thrust compared with rigid rays is minimal. Moreover, our results show that flexible rays can improve the propulsive efficiency compared with a rigid counterpart. Finally, we find that the morphology of ribbon fin affects its propulsive efficiency. For the aspect ratio considered in our experiments, [Formula: see text] was the most efficient compared with [Formula: see text]. Our results suggest that there could be an optimal morphology for a given ribbon fin kinematics. Therefore, both natural swimmers and underwater vehicles using ribbon-fin-based propulsion can take advantage of flexible rays and optimal aspect ratio to improve propulsive performance.
Soft hub for bearingless rotors
NASA Technical Reports Server (NTRS)
Dixon, Peter G. C.
1991-01-01
Soft hub concepts which allow the direct replacement of articulated rotor systems by bearingless types without any change in controllability or need for reinforcement to the drive shaft and/or transmission/fuselage attachments of the helicopter were studied. Two concepts were analyzed and confirmed for functional and structural feasibility against a design criteria and specifications established for this effort. Both systems are gimballed about a thrust carrying universal elastomeric bearing. One concept includes a set of composite flexures for drive torque transmittal from the shaft to the rotor, and another set (which is changeable) to impart hub tilting stiffness to the rotor system as required to meet the helicopter application. The second concept uses a composite bellows flexure to drive the rotor and to augment the hub stiffness provided by the elastomeric bearing. Each concept was assessed for weight, drag, ROM cost, and number of parts and compared with the production BO-105 hub.
Mechanical properties of new dental pulp-capping materials.
Nielsen, Matthew J; Casey, Jeffery A; VanderWeele, Richard A; Vandewalle, Kraig S
2016-01-01
The mechanical properties of pulp-capping materials may affect their resistance to fracture during placement of a final restorative material or while supporting an overlying restoration over time. The purpose of this study was to compare the compressive strength, flexural strength, and flexural modulus of 2 new pulp-capping materials (TheraCal LC and Biodentine), mineral trioxide aggregate (MTA), and calcium hydroxide over time. Specimens were created in molds and tested to failure in a universal testing machine after 15 minutes, 3 hours, and 24 hours. The MTA specimens did not set at 15 minutes. At all time periods, TheraCal LC had the greatest compressive and flexural strengths. After 3 and 24 hours, Biodentine had the greatest flexural modulus. TheraCal LC had greater early strength to potentially resist fracture during immediate placement of a final restorative material. Biodentine had greater stiffness after 3 hours to potentially provide better support of an overlying restoration under function over time.
NASA Astrophysics Data System (ADS)
Kouroussis, G.; Verlinden, O.; Conti, C.
2012-04-01
A study is performed on the influence of some typical railway vehicle and track parameters on the level of ground vibrations induced in the neighbourhood. The results are obtained from a previously validated simulation framework considering in a first step the vehicle/track subsystem and, in a second step, the response of the soil to the forces resulting from the first analysis. The vehicle is reduced to a simple vertical 3-dof model, corresponding to the superposition of the wheelset, the bogie and the car body. The rail is modelled as a succession of beam elements elastically supported by the sleepers, lying themselves on a flexible foundation representing the ballast and the subgrade. The connection between the wheels and the rails is realised through a non-linear Hertzian contact. The soil motion is obtained from a finite/infinite element model. The investigated vehicle parameters are its type (urban, high speed, freight, etc.) and its speed. For the track, the rail flexural stiffness, the railpad stiffness, the spacing between sleepers and the rail and sleeper masses are considered. In all cases, the parameter value range is defined from a bibliographic browsing. At the end, the paper proposes a table summarising the influence of each studied parameter on three indicators: the vehicle acceleration, the rail velocity and the soil velocity. It namely turns out that the vehicle has a serious influence on the vibration level and should be considered in prediction models.
Improving the performance of auto-parametric pendulum absorbers by means of a flexural beam
NASA Astrophysics Data System (ADS)
Mahmoudkhani, S.
2018-07-01
Auto-parametric pendulum absorbers perform well only in a very limited range of excitation amplitudes, above which their efficiency would be substantially degraded as a consequence of spillover effects or appearance of quasi-periodic and chaotic responses. For improving the performance against this drawback, the rigid pendulum is replaced in the present study with a low-stiffness viscoelastic beam. An additional one-to-three internal resonance between the almost non-flexural rotational and the first flexural modes of the beam is also introduced. With the aid of this internal resonance, the energy that has been transferred to the absorber due to the one-to-two internal resonance would be avoided from being transferred back to the primary system by faster dissipation of vibrations at a higher-frequency mode thereby leading to lower spillover effects. For modeling purpose, the tracking frame with the rigid-body constraint and also the third-order nonlinear beam theory are employed to account for arbitrarily large rotation angles coupled to moderately large elastic deformations. The assumed-mode method is also used to obtain discretized equations of motion. The numerical continuation of periodic solution is performed and the bifurcations with detrimental effects on the performance are determined. Various parametric studies are also conducted which show that by proper setting of the system parameters, higher efficiencies at much wider range of excitation amplitudes could be achieved.
Development of 1-m primary mirror for a spaceborne camera
NASA Astrophysics Data System (ADS)
Kihm, Hagyong; Yang, Ho-Soon; Rhee, Hyug-Gyo; Lee, Yun-Woo
2015-09-01
We present the development of a 1-m lightweight mirror system for a spaceborne electro-optical camera. The mirror design was optimized to satisfy the performance requirements under launch loads and space environment. The mirror made of Zerodur® has pockets at the back surface and three square bosses at the rim. Metallic bipod flexures support the mirror at the bosses and adjust the mirror's surface distortion due to gravity. We also show an analytical formulation of the bipod flexure, where compliance and stiffness matrices of the bipod flexure are derived to estimate theoretical performance and to make initial design guidelines. Optomechanical performances such as surface distortions due to gravity is explained. Environmental verification of the mirror is achieved by vibration tests.
Atomic force microscopy capable of vibration isolation with low-stiffness Z-axis actuation.
Ito, Shingo; Schitter, Georg
2018-03-01
For high-resolution imaging without bulky external vibration isolation, this paper presents an atomic force microscope (AFM) capable of vibration isolation with its internal Z-axis (vertical) actuators moving the AFM probe. Lorentz actuators (voice coil actuators) are used for the Z-axis actuation, and flexures guiding the motion are designed to have a low stiffness between the mover and the base. The low stiffness enables a large Z-axis actuation of more than 700 µm and mechanically isolates the probe from floor vibrations at high frequencies. To reject the residual vibrations, the probe tracks the sample by using a displacement sensor for feedback control. Unlike conventional AFMs, the Z-axis actuation attains a closed-loop control bandwidth that is 35 times higher than the first mechanical resonant frequency. The closed-loop AFM system has robustness against the flexures' nonlinearity and uses the first resonance for better sample tracking. For further improvement, feedforward control with a vibration sensor is combined, and the resulting system rejects 98.4% of vibrations by turning on the controllers. The AFM system is demonstrated by successful AFM imaging in a vibrational environment. Copyright © 2017 Elsevier B.V. All rights reserved.
Jain, Ankit; Nair, Pradeep R.; Alam, Muhammad A.
2012-01-01
In this article, we propose a Flexure-FET (flexure sensitive field effect transistor) ultrasensitive biosensor that utilizes the nonlinear electromechanical coupling to overcome the fundamental sensitivity limits of classical electrical or mechanical nanoscale biosensors. The stiffness of the suspended gate of Flexure-FET changes with the capture of the target biomolecules, and the corresponding change in the gate shape or deflection is reflected in the drain current of FET. The Flexure-FET is configured to operate such that the gate is biased near pull-in instability, and the FET-channel is biased in the subthreshold regime. In this coupled nonlinear operating mode, the sensitivity (S) of Flexure-FET with respect to the captured molecule density (Ns) is shown to be exponentially higher than that of any other electrical or mechanical biosensor. In other words, while , classical electrical or mechanical biosensors are limited to Sclassical ∼ γ3NS or γ4 ln(NS), where γi are sensor-specific constants. In addition, the proposed sensor can detect both charged and charge-neutral biomolecules, without requiring a reference electrode or any sophisticated instrumentation, making it a potential candidate for various low-cost, point-of-care applications. PMID:22623527
NASA Technical Reports Server (NTRS)
Bert, C. W.; Chang, S.
1972-01-01
Elastic and damping analyses resulting in determinations of the various stiffnesses and associated loss tangents for the complete characterization of the elastic and damping behavior of a monofilament composite layer are presented. For the determination of the various stiffnesses, either an elementary mechanics-of-materials formulation or a more rigorous mixed-boundary-value elasticity formulation is used. The solution for the latter formulation is obtained by means of the boundary-point least-square error technique. Kimball-Lovell type damping is assumed for each of the constituent materials. For determining the loss tangents associated with the various stiffnesses, either the viscoelastic correspondence principle or an energy analysis based on the appropriate elastic stress distribution is used.
Flexible flapping wings with self-organized microwrinkles.
Tanaka, Hiroto; Okada, Hiroyuki; Shimasue, Yosuke; Liu, Hao
2015-06-29
Bio-inspired flapping wings with a wrinkled wing membrane were designed and fabricated. The wings consist of carbon fibre-reinforced plastic frames and a polymer film with microscale wrinkles inspired by bird feathers and the corrugations of insect wings. The flexural and tensile stiffness of the wrinkled film can be controlled by modifying the orientations and waveforms of the wrinkles, thereby expanding the design space of flexible wings for micro flapping-wing aerial robots. A self-organization phenomenon was exploited in the fabrication of the microwrinkles such that microscale wrinkles spanning a broad wing area were spontaneously created. The wavy shape of these self-organized wrinkles was used as a mould, and a Parylene film was deposited onto the mould to form a wrinkled wing film. The effect of the waveforms of the wrinkles on the film stiffness was investigated theoretically, computationally and experimentally. Compared with a flat film, the flexural stiffness was increased by two orders of magnitude, and the tensile stiffness was reduced by two orders of magnitude. To demonstrate the effect of the wrinkles on the actual deformation of the flapping wings and the resulting aerodynamic forces, the fabricated wrinkled wings were tested using a tethered electric flapping mechanism. Chordwise unidirectional wrinkles were found to prevent fluttering near the trailing edge and to produce a greater aerodynamic lift compared with a flat wing or a wing with spanwise wrinkles. Our results suggest that the fine stiffness control of the wing film that can be achieved by tuning the microwrinkles can improve the aerodynamic performance of future flapping-wing aerial robots.
Ontogeny of Feeding Mechanics in Smoothhound Sharks: Morphology and Cartilage Stiffness.
Wilga, Cheryl A D; Diniz, Stephanye E; Steele, Preston R; Sudario-Cook, Jordan; Dumont, Elizabeth R; Ferry, Lara A
2016-09-01
The diet of dusky smoothhound sharks, Mustelus canis, shifts over ontogeny from soft foods to a diet dominated by crabs. This may be accompanied by changes in the skeletal system that facilitates the capture and processing of large and bulky prey. The hyoid arch, for example, braces the jaws against the cranium, and generates suction for prey capture and intraoral transport. In this study, ontogenetic changes in the hyoid arch were investigated by quantifying size, mineralization, and stiffness to determine whether increasingly stiffer cartilages are associated with the dietary switch. Total length and length of the hyomandibula and ceratohyal cartilages over ontogeny were the proxy for body size. Cross-sectional area, percent mineralization, and second moment of area were quantified in 28 individuals spanning most of the natural size range. Mechanical compression tests were conducted to compare flexural stiffness to size. Our results show that the morphological characters tested for the hyomandibular and ceratohyal cartilages scales isometrically with length. While stiffness of the hyomandibular and ceratohyal cartilages scales isometrically with length when assessed on morphological characters alone (second moment of area), this relationship becomes allometric when mechanical properties are included (flexural stiffness). Thus, while the hyoid arch elements grow isometrically, the mechanical properties dictate a scaling relationship that dwarfs morphological characteristics. The various combinations of morphologies and ontogenetic trajectories of chondrichthyan species illustrate the tremendous flexibility that they possess in the functional organization of the feeding apparatus. © The Author 2016. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.
Boehm, K. -J.; Gibson, C. R.; Hollaway, J. R.; ...
2016-09-01
This study presents the design of a flexure-based mount allowing adjustment in three rotational degrees of freedom (DOFs) through high-precision set-screw actuators. The requirements of the application called for small but controlled angular adjustments for mounting a cantilevered beam. The proposed design is based on an array of parallel beams to provide sufficiently high stiffness in the translational directions while allowing angular adjustment through the actuators. A simplified physical model in combination with standard beam theory was applied to estimate the deflection profile and maximum stresses in the beams. A finite element model was built to calculate the stresses andmore » beam profiles for scenarios in which the flexure is simultaneously actuated in more than one DOF.« less
Flexural Behavior of GFRP Tubes Filled with Magnetically Driven Concrete
Xie, Fang; Chen, Ju; Dong, Xinlong; Feng, Bing
2018-01-01
Experimental investigation of GFRP (glass fiber reinforced polymer) tubes that were filled with magnetically driven concrete was carried out to study the flexural behavior of specimens under bending. Specimens having different cross section and lengths were tested. The test specimens were fabricated by filling magnetically driven concrete into the GFRP tubes and the concrete was vibrated using magnetic force. Specimens vibrated using vibrating tube were also tested for comparison. In addition, specimens having steel reinforcing bars and GFRP bars were both tested to study the effect of reinforcing bars on the magnetically driven concrete. The load-displacement curves, load-strain curves, failure mode, and ultimate strengths of test specimens were obtained. Design methods for the flexural stiffness of test specimens were also discussed in this study. PMID:29316732
Flexural Behavior of GFRP Tubes Filled with Magnetically Driven Concrete.
Xie, Fang; Chen, Ju; Dong, Xinlong; Feng, Bing
2018-01-08
Experimental investigation of GFRP (glass fiber reinforced polymer) tubes that were filled with magnetically driven concrete was carried out to study the flexural behavior of specimens under bending. Specimens having different cross section and lengths were tested. The test specimens were fabricated by filling magnetically driven concrete into the GFRP tubes and the concrete was vibrated using magnetic force. Specimens vibrated using vibrating tube were also tested for comparison. In addition, specimens having steel reinforcing bars and GFRP bars were both tested to study the effect of reinforcing bars on the magnetically driven concrete. The load-displacement curves, load-strain curves, failure mode, and ultimate strengths of test specimens were obtained. Design methods for the flexural stiffness of test specimens were also discussed in this study.
NASA Technical Reports Server (NTRS)
Nemeth, Michael P.
2004-01-01
An approach for synthesizing buckling results for thin balanced and unbalanced symmetric laminates that are subjected to uniform heating or cooling and elastically restrained against thermal expansion or contraction is presented. This approach uses a nondimensional analysis for infinitely long, flexural anisotropic plates that are subjected to combined mechanical loads. In addition, stiffness-weighted laminate thermal-expansion parameters and compliance coefficients are derived that are used to determine critical temperatures in terms of physically intuitive mechanical-buckling coefficients. Many results are presented for some common laminates that are intended to facilitate a structural designer s transition to the use of the generic buckling design curves. Several curves that illustrate the fundamental parameters used in the analysis are presented, for nine contemporary material systems, that provide physical insight into the buckling response in addition to providing useful design data. Examples are presented that demonstrate the use of the generic design curves.
Optimal design of high-rise buildings with respect to fundamental eigenfrequency
NASA Astrophysics Data System (ADS)
Alavi, Arsalan; Rahgozar, Reza; Torkzadeh, Peyman; Hajabasi, Mohamad Ali
2017-12-01
In modern tall and slender structures, dynamic responses are usually the dominant design requirements, instead of strength criteria. Resonance is often a threatening phenomenon for such structures. To avoid this problem, the fundamental eigenfrequency, an eigenfrequency of higher order, should be maximized. An optimization problem with this objective is constructed in this paper and is applied to a high-rise building. Using variational method, the objective function is maximized, contributing to a particular profile for the first mode shape. Based on this preselected profile, a parametric formulation for flexural stiffness is calculated. Due to some near-zero values for stiffness, the obtained formulation will be modified by adding a lower bound constraint. To handle this constraint some new parameters are introduced; thereby allowing for construction of a model relating the unknown parameters. Based on this mathematical model, a design algorithmic procedure is presented. For the sake of convenience, a single-input design graph is presented as well. The main merit of the proposed method, compared to previous researches, is its hand calculation aspect, suitable for parametric studies and sensitivity analysis. As the presented formulations are dimensionless, they are applicable in any dimensional system. Accuracy and practicality of the proposed method is illustrated at the end by applying it to a real-life structure.
The effect of intrinsic crumpling on the mechanics of free-standing graphene
NASA Astrophysics Data System (ADS)
Nicholl, Ryan J. T.; Conley, Hiram J.; Lavrik, Nickolay V.; Vlassiouk, Ivan; Puzyrev, Yevgeniy S.; Sreenivas, Vijayashree Parsi; Pantelides, Sokrates T.; Bolotin, Kirill I.
2015-11-01
Free-standing graphene is inherently crumpled in the out-of-plane direction due to dynamic flexural phonons and static wrinkling. We explore the consequences of this crumpling on the effective mechanical constants of graphene. We develop a sensitive experimental approach to probe stretching of graphene membranes under low applied stress at cryogenic to room temperatures. We find that the in-plane stiffness of graphene is 20-100 N m-1 at room temperature, much smaller than 340 N m-1 (the value expected for flat graphene). Moreover, while the in-plane stiffness only increases moderately when the devices are cooled down to 10 K, it approaches 300 N m-1 when the aspect ratio of graphene membranes is increased. These results indicate that softening of graphene at temperatures <400 K is caused by static wrinkling, with only a small contribution due to flexural phonons. Together, these results explain the large variation in reported mechanical constants of graphene devices and pave the way towards controlling their mechanical properties.
NASA Astrophysics Data System (ADS)
Roopa, R.; Navin Karanth, P.; Kulkarni, S. M.
2018-02-01
In this paper, we present a COMSOL analysis of flexure diaphragm for piezo actuated valveless micropump. Diaphragms play an important role in micropumps, till now plane diaphragms are commonly used in micropumps. Use of compliant flexure hinges in diaphragm and other MEMS application is one of the new approach to achieving high deflection in diaphragm at low operating voltage. Flexures hinges in diaphragm acts as simply supported beam. Out-off plane compliance value and stiffness is considered for the selection of proper flexure for diaphragm. Diaphragm material also plays an important role in the diaphragm central deflection. Factor considered for diaphragm material selection is resilience; it is the ratio of yield stress to static modulus. Higher is the resilience will leads to higher deflection generated, it also imparts good compliance. Based on the resilience beryllium copper, stainless steel and brass materials are selected for diaphragm analysis. Simulations have been performed using COMSOL multiphysics. This study reports the effect of flexure hinge geometry and diaphragm material on the central deflection of diaphragms and compared with existing plane diaphragm. Simulation results illustrates that the deflection of three flexure diaphragm with 2mm width and 2mm length flexure is 6.75µm for stainless steel, 10.89 for beryllium copper and 12.10µm for brass, at 140V which is approximately twice that of plane diaphragm deflection. The maximum in both plane and three flexure diaphragm deflection is obtained for brass diaphragm compared to stainless steel and beryllium copper.
NASA Astrophysics Data System (ADS)
Jaya Christiyan, K. G.; Chandrasekhar, U.; Mathivanan, N. Rajesh; Venkateswarlu, K.
2018-02-01
A 3D printing was successfully used to fabricate samples of Polylactic Acid (PLA). Processing parameters such as Lay-up speed, Lay-up thickness, and printing nozzle were varied. All samples were tested for flexural strength using three point load test. A statistical mathematical model was developed to correlate the processing parameters with flexural strength. The result clearly demonstrated that the lay-up thickness and nozzle diameter influenced flexural strength significantly, whereas lay-up speed hardly influenced the flexural strength.
Soares, Carlos Jose; Santana, Fernanda Ribeiro; Pereira, Janaina Carla; Araujo, Tatiana Santos; Menezes, Murilo Souza
2008-06-01
Controversy exists concerning the use of fiber-reinforced posts to improve bond strength to resin cement because some precementation treatments can compromise the mechanical properties of the posts. The purpose of this study was to analyze the influence of airborne-particle abrasion on the mechanical properties and microtensile bond strength (MTBS) of carbon/epoxy and glass/bis-GMA fiber-reinforced resin posts. Flexural strength (delta(f)), flexural modulus (E(f)), and stiffness (S) were assessed using a 3-point bending test for glass fiber-reinforced and carbon fiber-reinforced resin posts submitted to airborne-particle abrasion (AB) with 50-microm Al(2)O(3), and for posts without any surface treatment (controls) (n=10). Forty glass fiber (GF) and 40 carbon fiber (CF) posts were submitted to 1 of 4 surface treatments (n=10) prior to MTBS testing: silane (S); silane and adhesive (SA); airborne-particle abrasion with 50-microm Al(2)O(3) and silane (ABS); airborne-particle abrasion, silane, and adhesive (ABSA). Two composite resin restorations (Filtek Z250) with rounded depressions in the lateral face were bilaterally fixed to the post with resin cement (RelyX ARC). Next, the specimen was sectioned with a precision saw running perpendicular to the bonded surface to obtain 10 bonded beam specimens with a cross-sectional area of 1 mm(2). Each beam specimen was tested in a mechanical testing machine (EMIC 2,000 DL), under stress, at a crosshead speed of 0.5 mm/min until failure. Data were analyzed by 2-way ANOVA followed by Tukey HSD test (alpha=.05). Failure patterns of tested specimens were analyzed using scanning electron microscopy (SEM). The 3-point bending test demonstrated significant differences among groups only for the post type factor for flexural strength, flexural modulus, and stiffness. The carbon fiber posts exhibited significantly higher mean flexural strength (P=.001), flexural modulus (P=.003), and stiffness (P=.001) values when compared with glass fiber posts, irrespective of surface treatment. An alteration in the superficial structure of the posts could be observed by SEM after airborne-particle abrasion. MTBS testing showed no significant effect for the surface treatment type; however, significant effects for post system factor and for interaction between the 2 factors were observed. For the carbon fiber post, the ABSA surface treatment resulted in values significantly lower than the S surface treatment. SEM analysis of MTBS-tested specimens demonstrated adhesive and cohesive failures. Airborne-particle abrasion did not influence the mechanical properties of the post; however, it produced undesirable surface changes, which could reduce the bond strength to resin cement. For the surface treatments studied, if silane is applied, the adhesive system and airborne-particle abrasion are not necessary.
Flexural support member having a high ratio of lateral-to-axial stiffness
Haas, W.M.B.
1983-06-23
A convoluted flexible support structure is provided which is capable of supplying a lateral to axial spring rate in excess of 1000 to 1. A support member in the form of a steel disc having a specified number of rather large radius, concentric convolutions and a thickness in the range of from about 0.01 to 0.02 inch has an axial stiffness of about 50 pounds/inch while the lateral stiffness is about 100,000 pounds/inch. The support member may be used to support a vibration device where the lateral motion of the vibrator must be highly restricted while providing relatively free axial displacement of about +-0.25 inch.
Flexural support member having a high ratio of lateral-to-axial stiffness
Haas, Wendall M. B.
1985-01-01
A convoluted flexible support structure is provided which is capable of supplying a lateral to axial spring rate in excess of 1,000 to 1. A support member in the form of a steel disc having a specified number of rather large radius, concentric convolutions and a thickness in the range of from about 0.01 to 0.02 inch has an axial stiffness of about 50 pounds/inch while the lateral stiffness is about 100,000 pounds/inch. The support member may be used to support a vibration device where the lateral motion of the vibrator must be highly restricted while providing relatively free axial displacement of about .+-.0.25 inch.
Prediction of Mean and Design Fatigue Lives of Self Compacting Concrete Beams in Flexure
NASA Astrophysics Data System (ADS)
Goel, S.; Singh, S. P.; Singh, P.; Kaushik, S. K.
2012-02-01
In this paper, result of an investigation conducted to study the flexural fatigue characteristics of self compacting concrete (SCC) beams in flexure are presented. An experimental programme was planned in which approximately 60 SCC beam specimens of size 100 × 100 × 500 mm were tested under flexural fatigue loading. Approximately 45 static flexural tests were also conducted to facilitate fatigue testing. The flexural fatigue and static flexural strength tests were conducted on a 100 kN servo-controlled actuator. The fatigue life data thus obtained have been used to establish the probability distributions of fatigue life of SCC using two-parameter Weibull distribution. The parameters of the Weibull distribution have been obtained by different methods of analysis. Using the distribution parameters, the mean and design fatigue lives of SCC have been estimated and compared with Normally vibrated concrete (NVC), the data for which have been taken from literature. It has been observed that SCC exhibits higher mean and design fatigue lives compared to NVC.
Propulsive performance of pitching foils with variable chordwise flexibility
NASA Astrophysics Data System (ADS)
Zeyghami, Samane; Moored, Keith; Lehigh University Team
2017-11-01
Many swimming and flying animals propel themselves efficiently through water by oscillating flexible fins. These fins are not homogeneously flexible, but instead their flexural stiffness varies along their chord and span. Here we seek to evaluate the effect stiffness profile on the propulsive performance of pitching foils. Stiffness profile characterizes the variation in the local fin stiffness along the chord. To this aim, we developed a low order model of a functionally-graded material where the chordwise flexibility is modeled by two torsional springs along the chordline and the stiffness and location of the springs can be varied arbitrarily. The torsional spring structural model is then strongly coupled to a boundary element fluid model to simulate the fluid-structure interactions. Keeping the leading edge kinematics unchanged, we alter the stiffness profile of the foil and allow it to swim freely in response to the resulting hydrodynamic forces. We then detail the dependency of the hydrodynamic performance and the wake structure to the variations in the local structural properties of the foil.
Variable stiffness sandwich panels using electrostatic interlocking core
NASA Astrophysics Data System (ADS)
Heath, Callum J. C.; Bond, Ian P.; Potter, Kevin D.
2016-04-01
Structural topology has a large impact on the flexural stiffness of a beam structure. Reversible attachment between discrete substructures allows for control of shear stress transfer between structural elements, thus stiffness modulation. Electrostatic adhesion has shown promise for providing a reversible latching mechanism for controllable internal connectivity. Building on previous research, a thin film copper polyimide laminate has been used to incorporate high voltage electrodes to Fibre Reinforced Polymer (FRP) sandwich structures. The level of electrostatic holding force across the electrode interface is key to the achievable level of stiffness modulation. The use of non-flat interlocking core structures can allow for a significant increase in electrode contact area for a given core geometry, thus a greater electrostatic holding force. Interlocking core geometries based on cosine waves can be Computer Numerical Control (CNC) machined from Rohacell IGF 110 Foam core. These Interlocking Core structures could allow for enhanced variable stiffness functionality compared to basic planar electrodes. This novel concept could open up potential new applications for electrostatically induced variable stiffness structures.
A lightweight, biological structure with tailored stiffness: The feather vane.
Sullivan, Tarah N; Pissarenko, Andreï; Herrera, Steven A; Kisailus, David; Lubarda, Vlado A; Meyers, Marc A
2016-09-01
The flying feathers of birds are keratinous appendages designed for maximum performance with a minimum weight penalty. Thus, their design contains ingenious combinations of components that optimize lift, stiffness, aerodynamics, and damage resistance. This design involves two main parts: a central shaft that prescribes stiffness and lateral vanes which allows for the capture of air. Within the feather vane, barbs branch from the shaft and barbules branch from barbs, forming a flat surface which ensures lift. Microhooks at the end of barbules hold barbs tightly together, providing the close-knit, unified structure of the feather vane and enabling a repair of the structure through the reattachment of un-hooked junctions. Both the shaft and barbs are lightweight biological structures constructed of keratin using the common motif of a solid shell and cellular interior. The cellular core increases the resistance to buckling with little added weight. Here we analyze the detailed structure of the feather barb and, for the first time, explain its flexural stiffness in terms of the mechanics of asymmetric foam-filled beams subjected to bending. The results are correlated and validated with finite element modeling. We compare the flexure of single barbs as well as arrays of barbs and find that the interlocking adherence of barbs to one another enables a more robust structure due to minimized barb rotation during deflection. Thus, the flexure behavior of the feather vane can be tailored by the adhesive hooking between barbs, creating a system that mitigates damage. A simplified three-dimensional physical model for this interlocking mechanism is constructed by additive manufacturing. The exceptional architecture of the feather vane will motivate the design of bioinspired structures with tailored and unique properties ranging from adhesives to aerospace materials. Despite its importance to bird flight, literature characterizing the feather vane is extremely limited. The feather vane is composed of barbs that branch from the main shaft (rachis) and barbules that branch from barbs. In this study, the flexural behavior of the feather barb and the role of barbule connections in reinforcing the feather vane are quantitatively investigated for the first time, both experimentally and theoretically. Through the performed experiments, structure-function relationships within the feather vane are uncovered. Additionally, in the proposed model the sophisticated structure of the barbs and the interlocking mechanism of the feather vane are simplified to understand these processes in order to engineer new lightweight structures and adhesives. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Tian, W; Wu, S C; Zhou, Z B; Qu, S B; Bai, Y Z; Luo, J
2012-09-01
High precision accelerometer plays an important role in space scientific and technical applications. A quartz-flexure accelerometer operating in low frequency range, having a resolution of better than 1 ng/Hz(1/2), has been designed based on advanced capacitive sensing and electrostatic control technologies. A high precision capacitance displacement transducer with a resolution of better than 2 × 10(-6) pF/Hz(1/2) above 0.1 Hz, is used to measure the motion of the proof mass, and the mechanical stiffness of the spring oscillator is compensated by adjusting the voltage between the proof mass and the electrodes to induce a proper negative electrostatic stiffness, which increases the mechanical sensitivity and also suppresses the position measurement noise down to 3 × 10(-10) g/Hz(1/2) at 0.1 Hz. A high resolution analog-to-digital converter is used to directly readout the feedback voltage applied on the electrodes in order to suppress the action noise to 4 × 10(-10) g/Hz(1/2) at 0.1 Hz. A prototype of the quartz-flexure accelerometer has been developed and tested, and the preliminary experimental result shows that its resolution comes to about 8 ng/Hz(1/2) at 0.1 Hz, which is mainly limited by its mechanical thermal noise due to low quality factor.
Zhang, Peng; Zhao, Ya-Nan; Li, Qing-Fu; Wang, Peng; Zhang, Tian-Hang
2014-01-01
This paper aims to clarify the effect of steel fiber on the flexural toughness of the high performance concrete containing fly ash and nano-SiO2. The flexural toughness was evaluated by two methods, which are based on ASTM C1018 and DBV-1998, respectively. By means of three-point bending method, the flexural toughness indices, variation coefficients of bearing capacity, deformation energy, and equivalent flexural strength of the specimen were measured, respectively, and the relational curves between the vertical load and the midspan deflection (P(V)-δ) were obtained. The results indicate that steel fiber has great effect on the flexural toughness parameters and relational curves (P(V)-δ) of the three-point bending beam specimen. When the content of steel fiber increases from 0.5% to 2%, the flexural toughness parameters increase gradually and the curves are becoming plumper and plumper with the increase of steel fiber content, respectively. However these flexural toughness parameters begin to decrease and the curves become thinner and thinner after the steel fiber content exceeds 2%. It seems that the contribution of steel fiber to the improvement of flexural toughness of the high performance concrete containing fly ash and nano-SiO2 is well performed only when the steel fiber content is less than 2%.
Gebisa, Aboma Wagari; Lemu, Hirpa G
2018-03-27
Fused-deposition modeling (FDM), one of the additive manufacturing (AM) technologies, is an advanced digital manufacturing technique that produces parts by heating, extruding and depositing filaments of thermoplastic polymers. The properties of FDM-produced parts apparently depend on the processing parameters. These processing parameters have conflicting advantages that need to be investigated. This article focuses on an investigation into the effect of these parameters on the flexural properties of FDM-produced parts. The investigation is carried out on high-performance ULTEM 9085 material, as this material is relatively new and has potential application in the aerospace, military and automotive industries. Five parameters: air gap, raster width, raster angle, contour number, and contour width, with a full factorial design of the experiment, are considered for the investigation. From the investigation, it is revealed that raster angle and raster width have the greatest effect on the flexural properties of the material. The optimal levels of the process parameters achieved are: air gap of 0.000 mm, raster width of 0.7814 mm, raster angle of 0°, contour number of 5, and contour width of 0.7814 mm, leading to a flexural strength of 127 MPa, a flexural modulus of 2400 MPa, and 0.081 flexural strain.
Gebisa, Aboma Wagari
2018-01-01
Fused-deposition modeling (FDM), one of the additive manufacturing (AM) technologies, is an advanced digital manufacturing technique that produces parts by heating, extruding and depositing filaments of thermoplastic polymers. The properties of FDM-produced parts apparently depend on the processing parameters. These processing parameters have conflicting advantages that need to be investigated. This article focuses on an investigation into the effect of these parameters on the flexural properties of FDM-produced parts. The investigation is carried out on high-performance ULTEM 9085 material, as this material is relatively new and has potential application in the aerospace, military and automotive industries. Five parameters: air gap, raster width, raster angle, contour number, and contour width, with a full factorial design of the experiment, are considered for the investigation. From the investigation, it is revealed that raster angle and raster width have the greatest effect on the flexural properties of the material. The optimal levels of the process parameters achieved are: air gap of 0.000 mm, raster width of 0.7814 mm, raster angle of 0°, contour number of 5, and contour width of 0.7814 mm, leading to a flexural strength of 127 MPa, a flexural modulus of 2400 MPa, and 0.081 flexural strain. PMID:29584674
Natural Kenaf Fiber Reinforced Composites as Engineered Structural Materials
NASA Astrophysics Data System (ADS)
Dittenber, David B.
The objective of this work was to provide a comprehensive evaluation of natural fiber reinforced polymer (NFRP)'s ability to act as a structural material. As a chemical treatment, aligned kenaf fibers were treated with sodium hydroxide (alkalization) in different concentrations and durations and then manufactured into kenaf fiber / vinyl ester composite plates. Single fiber tensile properties and composite flexural properties, both in dry and saturated environments, were assessed. Based on ASTM standard testing, a comparison of flexural, tensile, compressive, and shear mechanical properties was also made between an untreated kenaf fiber reinforced composite, a chemically treated kenaf fiber reinforced composite, a glass fiber reinforced composite, and oriented strand board (OSB). The mechanical properties were evaluated for dry samples, samples immersed in water for 50 hours, and samples immersed in water until saturation (~2700 hours). Since NFRPs are more vulnerable to environmental effects than synthetic fiber composites, a series of weathering and environmental tests were conducted on the kenaf fiber composites. The environmental conditions studied include real-time outdoor weathering, elevated temperatures, immersion in different pH solutions, and UV exposure. In all of these tests, degradation was found to be more pronounced in the NFRPs than in the glass FRPs; however, in nearly every case the degradation was less than 50% of the flexural strength or stiffness. Using a method of overlapping and meshing discontinuous fiber ends, large mats of fiber bundles were manufactured into composite facesheets for structural insulated panels (SIPs). The polyisocyanurate foam cores proved to be poorly matched to the strength and stiffness of the NFRP facesheets, leading to premature core shear or delamination failures in both flexure and compressive testing. The NFRPs were found to match well with the theoretical stiffness prediction methods of classical lamination theory, finite element method, and Castigliano's method in unidirectional tension and compression, but are less accurate for the more bond-dependent flexural and shear properties. With the acknowledged NFRP matrix bonding issues, the over-prediction of these theoretical models indicates that the flexural stiffness of the kenaf composite may be increased by up to 40% if a better bond between the fiber and matrix can be obtained. The sustainability of NFRPs was examined from two perspectives: environmental and socioeconomic. While the kenaf fibers themselves possess excellent sustainability characteristics, costing less while possessing a lesser environmental impact than the glass fibers, the vinyl ester resin used in the composites is environmentally hazardous and inflated the cost and embodied energy of the composite SIPs. Consistent throughout all the designs was a correlation between the respective costs of the raw materials and the respective environmental impacts. The socioeconomic study looked at the sustainability of natural fiber reinforced composite materials as housing materials in developing countries. A literature study on the country of Bangladesh, where the fibers in this study were grown, showed that the jute and kenaf market would benefit from the introduction of a value-added product like natural fiber composites. The high rate of homeless and inadequately housed in Bangladesh, as well as in the US and throughout the rest of the world, could be somewhat alleviated if a new, affordable, and durable material were introduced. While this study found that natural fiber composites possess sufficient mechanical properties to be adopted as primary structural members, the two major remaining hurdles needing to be overcome before natural fiber composites can be adopted as housing materials are the cost and sustainability of the resin system and the moisture resistance/durability of the fibers. (Abstract shortened by UMI.)
EFFECTS OF CYCLIC FLEXURAL FATIGUE ON PORCINE BIOPROSTHETIC HEART VALVE HETEROGRAFT BIOMATERIALS
Mirnajafi, Ali; Zubiate, Brett; Sacks, Michael S.
2009-01-01
While bioprosthetic heart valves (BHV) remain the primary treatment modality for adult heart valve replacement, continued problems with durability remain. Several studies have implicated flexure as a major damage mode in porcine-derived heterograft biomaterials used in BHV fabrication. While conventional accelerated wear testing can provide valuable insights into BHV damage phenomena, the constituent tissues are subjected to complex, time-varying deformation modes (i.e. tension and flexure), that do not allow for the control of the amount, direction, and location of flexure. Thus, in the present study customized fatigue testing devices were developed to subject circumferentially oriented porcine BHV tissue strips to controlled cyclic flexural loading. By using this approach, we were able to study layer-specific structural damage induced by cyclic flexural tensile and compressive stresses alone. 10×106, 25×106 and 50×106 cycle levels were used, with resulting changes in flexural stiffness and collagen structure assessed. Results indicated that flexural rigidity was markedly reduced after only 10×106 cycles, and progressively decayed at a lower rate with cycle number thereafter. Moreover, the against-curvature fatigue direction induced the most damage, suggesting that the ventricularis and fibrosa layers have low resistance to cyclic flexural compressive and tensile loads, respectively. The histological analyses indicated progressive collagen fiber delamination as early as 10×106 cycles, but otherwise no change in gross collagen orientation. Our results underscore that porcine-derived heterograft biomaterials are very sensitive to flexural fatigue, with delamination of the tissue layers the primary underlying mechanism. This appears to be in contrast to pericardial BHV, wherein high tensile stresses are considered to be the major cause of structural failure. These findings point towards the need for the development of chemical fixation technologies that minimize flexure induced damage to extend porcine heterograft biomaterial durability. PMID:20166221
A novel variable stiffness mechanism for dielectric elastomer actuators
NASA Astrophysics Data System (ADS)
Li, Wen-Bo; Zhang, Wen-Ming; Zou, Hong-Xiang; Peng, Zhi-Ke; Meng, Guang
2017-08-01
In this paper, a novel variable stiffness mechanism is proposed for the design of a variable stiffness dielectric elastomer actuator (VSDEA) which combines a flexible strip with a DEA in a dielectric elastomer minimum energy structure. The DEA induces an analog tuning of the transverse curvature of the strip, thus conveniently providing a voltage-controllable flexural rigidity. The VSDEA tends to be a fully flexible and compact structure with the advantages of simplicity and fast response. Both experimental and theoretical investigations are carried out to reveal the variable stiffness performances of the VSDEA. The effect of the clamped location on the bending stiffness of the VSDEA is analyzed, and then effects of the lengths, the loading points and the applied voltages on the bending stiffness are experimentally investigated. An analytical model is developed to verify the availability of this variable stiffness mechanism, and the theoretical results demonstrate that the bending stiffness of the VSDEA decreases as the applied voltage increases, which agree well with the experimental data. Moreover, the experimental results show that the maximum change of the relative stiffness can reach about 88.80%. It can be useful for the design and optimization of active variable stiffness structures and DEAs for soft robots, vibration control, and morphing applications.
Strain-energy release rate analysis of a laminate with a postbuckled delamination
NASA Technical Reports Server (NTRS)
Whitcomb, John D.; Shivakumar, K. N.
1987-01-01
The objectives are to present the derivation of the new virtual crack closure technique, evaluate the accuracy of the technique, and finally to present the results of a limited parametric study of laminates with a postbuckled delamination. Although the new virtual crack closure technique is general, only homogeneous, isotropic laminates were analyzed. This was to eliminate the variation of flexural stiffness with orientation, which occurs even for quasi-isotropic laminates. This made it easier to identify the effect of geometrical parameters on G. The new virtual crack closure technique is derived. Then the specimen configurations are described. Next, the stress analyses is discussed. Finally, the virtual crack closure technique is evaluated and then used to calculate the distribution of G along the delamination front of several laminates with a postbuckled delamination.
Zhao, Ya-Nan; Li, Qing-Fu; Wang, Peng; Zhang, Tian-Hang
2014-01-01
This paper aims to clarify the effect of steel fiber on the flexural toughness of the high performance concrete containing fly ash and nano-SiO2. The flexural toughness was evaluated by two methods, which are based on ASTM C1018 and DBV-1998, respectively. By means of three-point bending method, the flexural toughness indices, variation coefficients of bearing capacity, deformation energy, and equivalent flexural strength of the specimen were measured, respectively, and the relational curves between the vertical load and the midspan deflection (P V-δ) were obtained. The results indicate that steel fiber has great effect on the flexural toughness parameters and relational curves (P V-δ) of the three-point bending beam specimen. When the content of steel fiber increases from 0.5% to 2%, the flexural toughness parameters increase gradually and the curves are becoming plumper and plumper with the increase of steel fiber content, respectively. However these flexural toughness parameters begin to decrease and the curves become thinner and thinner after the steel fiber content exceeds 2%. It seems that the contribution of steel fiber to the improvement of flexural toughness of the high performance concrete containing fly ash and nano-SiO2 is well performed only when the steel fiber content is less than 2%. PMID:24883395
The effect of intrinsic crumpling on the mechanics of free-standing graphene
Nicholl, Ryan J. T.; Conley, Hiram J.; Lavrik, Nickolay V.; ...
2015-11-06
Free-standing graphene is inherently crumpled in the out-of-plane direction due to dynamic flexural phonons and static wrinkling. We explore the consequences of this crumpling on the effective mechanical constants of graphene. We develop a sensitive experimental approach to probe stretching of graphene membranes under low applied stress at cryogenic to room temperatures. We find that the in-plane stiffness of graphene is 20–100 N m –1 at room temperature, much smaller than 340 N m –1 (the value expected for flat graphene). Moreover, while the in-plane stiffness only increases moderately when the devices are cooled down to 10 K, it approachesmore » 300 N m –1 when the aspect ratio of graphene membranes is increased. Finally, these results indicate that softening of graphene at temperatures <400 K is caused by static wrinkling, with only a small contribution due to flexural phonons. Altogether, these results explain the large variation in reported mechanical constants of graphene devices and pave the way towards controlling their mechanical properties.« less
NASA Astrophysics Data System (ADS)
Nozawa, T.; Hinoki, T.; Katoh, Y.; Kohyama, A.
2002-12-01
Radiation effects on flexural properties of SiC/SiC composites fabricated by forced thermal gradient chemical vapor infiltration (F-CVI) process, reaction sintered (RS) process and polymer impregnation and pyrolysis (PIP) process were investigated. In this study, neutron irradiation at 1073 K up to 0.4×10 25 n/m 2 ( E>0.1 MeV) was performed. For F-CVI and RS SiC/SiC, due to the irradiation damage of interphase like pyrolytic carbon and boron nitride, which were sensitive to neutron irradiation, composite stiffness was slightly decreased. On the contrary, for PIP SiC/SiC, there was no significant change in stiffness before and after irradiation. Composite strength, however, was nearly stable against high-temperature irradiation with such a low fluence, except for RS SiC/SiC, since mechanical characteristics of fiber and matrix themselves were still stable to neutron irradiation. However RS SiC/SiC had a slight reduction of flexural strength due to the severe degradation of the interface by neutron irradiation.
The effect of intrinsic crumpling on the mechanics of free-standing graphene
Nicholl, Ryan J.T.; Conley, Hiram J.; Lavrik, Nickolay V.; Vlassiouk, Ivan; Puzyrev, Yevgeniy S.; Sreenivas, Vijayashree Parsi; Pantelides, Sokrates T.; Bolotin, Kirill I.
2015-01-01
Free-standing graphene is inherently crumpled in the out-of-plane direction due to dynamic flexural phonons and static wrinkling. We explore the consequences of this crumpling on the effective mechanical constants of graphene. We develop a sensitive experimental approach to probe stretching of graphene membranes under low applied stress at cryogenic to room temperatures. We find that the in-plane stiffness of graphene is 20–100 N m−1 at room temperature, much smaller than 340 N m−1 (the value expected for flat graphene). Moreover, while the in-plane stiffness only increases moderately when the devices are cooled down to 10 K, it approaches 300 N m−1 when the aspect ratio of graphene membranes is increased. These results indicate that softening of graphene at temperatures <400 K is caused by static wrinkling, with only a small contribution due to flexural phonons. Together, these results explain the large variation in reported mechanical constants of graphene devices and pave the way towards controlling their mechanical properties. PMID:26541811
Parametric Study on Responses of a Self-Anchored Suspension Bridge to Sudden Breakage of a Hanger
Jiang, Meng; Huang, Cailiang
2014-01-01
The girder of self-anchored suspension bridge is subjected to large compression force applied by main cables. So, serious damage of the girder due to breakage of hangers may cause the collapse of the whole bridge. With the time increasing, the hangers may break suddenly for their resistance capacities decrease due to corrosion. Using nonlinear static and dynamic analysis methods and adopting 3D finite element model, the responses of an actual self-anchored suspension bridge to sudden breakage of hangers are studied in this paper. The results show that the sudden breakage of a hanger causes violent vibration and large changes in internal forces of the bridge. In the process of the vibration, the maximum tension of hanger produced by breakage of a hanger exceeds 2.22 times its initial value, and the reaction forces of the bearings increase by more than 1.86 times the tension of the broken hanger. Based on the actual bridge, the influences of some factors including flexural stiffness of girder, torsion stiffness of girder, flexural stiffness of main cable, weight of girder, weight of main cable, span to sag ratio of main cable, distance of hangers, span length, and breakage time of hanger on the dynamic responses are studied in detail, and the influencing extent of the factors is presented. PMID:25045734
Parametric study on responses of a self-anchored suspension bridge to sudden breakage of a hanger.
Qiu, Wenliang; Jiang, Meng; Huang, Cailiang
2014-01-01
The girder of self-anchored suspension bridge is subjected to large compression force applied by main cables. So, serious damage of the girder due to breakage of hangers may cause the collapse of the whole bridge. With the time increasing, the hangers may break suddenly for their resistance capacities decrease due to corrosion. Using nonlinear static and dynamic analysis methods and adopting 3D finite element model, the responses of an actual self-anchored suspension bridge to sudden breakage of hangers are studied in this paper. The results show that the sudden breakage of a hanger causes violent vibration and large changes in internal forces of the bridge. In the process of the vibration, the maximum tension of hanger produced by breakage of a hanger exceeds 2.22 times its initial value, and the reaction forces of the bearings increase by more than 1.86 times the tension of the broken hanger. Based on the actual bridge, the influences of some factors including flexural stiffness of girder, torsion stiffness of girder, flexural stiffness of main cable, weight of girder, weight of main cable, span to sag ratio of main cable, distance of hangers, span length, and breakage time of hanger on the dynamic responses are studied in detail, and the influencing extent of the factors is presented.
Effects of phyllotaxy on biomechanical properties of stems of Cercis occidentalis (Fabaceae).
Caringella, Marissa A; Bergman, Brett A; Stanfield, Ryan C; Ewers, Madeleine M; Bobich, Edward G; Ewers, Frank W
2014-01-01
Phyllotaxy, the arrangement of leaves on a stem, may impact the mechanical properties of woody stems several years after the leaves have been shed. We explored mechanical properties of a plant with alternate distichous phyllotaxy, with a row of leaves produced on each side of the stem, to determine whether the nodes behave as spring-like joints. Flexural stiffness of 1 cm diameter woody stems was measured in four directions with an Instron mechanical testing system; the xylem of the stems was then cut into node (former leaf junction) and nonnode segments for measurement of xylem density. Stems had 20% greater flexural stiffness in the plane perpendicular to the original leaf placement than in the parallel plane. The xylem in the node region was more flexible, but it had significantly greater tissue density than adjacent regions, contradicting the usual correlation between wood density and stiffness. Nodes can behave as spring-like joints in woody plants. For plagiotropic shoots, distichous phyllotaxy results in stems that resist up-and-down bending more than lateral back-and-forth movement. Thus, they may more effectively absorb applied loads from fruits, animals, wind, rain, and snow and resist stresses due to gravity without cracking and breaking. Under windy conditions, nodes may improve damping by absorbing vibrational energy and thus reducing oscillation damage. The effect of plant nodes also has biomimetic design implications for architects and material engineers.
Sweeping shunted electro-magnetic tuneable vibration absorber: Design and implementation
NASA Astrophysics Data System (ADS)
Turco, E.; Gardonio, P.
2017-10-01
This paper presents a study on the design and implementation of a time-varying shunted electro-magnetic Tuneable Vibration Absorber for broad-band vibration control of thin structures. A time-varying RL-shunt is used to harmonically vary the stiffness and damping properties of the Tuneable Vibration Absorber so that its mechanical fundamental natural frequency is continuously swept in a given broad frequency band whereas its mechanical damping is continuously adapted to maximize the vibration absorption from the hosting structure where it is mounted. The paper first recalls the tuning and positioning criteria for the case where a classical Tuneable Vibration Absorber is installed on a thin walled cylindrical structure to reduce the response of a resonating flexural mode. It then discusses the design of the time-varying shunt circuit to produce the desired stiffness and damping variations in the electro-magnetic Tuneable Vibration Absorber. Finally, it presents a numerical study on the flexural vibration and interior sound control effects produced when an array of these shunted electro-magnetic Tuneable Vibration Absorbers are mounted on a thin walled cylinder subject to a rain-on-the-roof stochastic excitation. The study shows that the array of proposed systems effectively controls the cylinder flexural response and interior noise over a broad frequency band without need of tuning and thus system identification of the structure. Therefore, the systems can be successfully used also on structures whose physical properties vary in time because of temperature changes or tensioning effects for example.
Elastic deformation and energy loss of flapping fly wings.
Lehmann, Fritz-Olaf; Gorb, Stanislav; Nasir, Nazri; Schützner, Peter
2011-09-01
During flight, the wings of many insects undergo considerable shape changes in spanwise and chordwise directions. We determined the origin of spanwise wing deformation by combining measurements on segmental wing stiffness of the blowfly Calliphora vicina in the ventral and dorsal directions with numerical modelling of instantaneous aerodynamic and inertial forces within the stroke cycle using a two-dimensional unsteady blade elementary approach. We completed this approach by an experimental study on the wing's rotational axis during stroke reversal. The wing's local flexural stiffness ranges from 30 to 40 nN m(2) near the root, whereas the distal wing parts are highly compliant (0.6 to 2.2 nN m(2)). Local bending moments during wing flapping peak near the wing root at the beginning of each half stroke due to both aerodynamic and inertial forces, producing a maximum wing tip deflection of up to 46 deg. Blowfly wings store up to 2.30 μJ elastic potential energy that converts into a mean wing deformation power of 27.3 μW. This value equates to approximately 5.9 and 2.3% of the inertial and aerodynamic power requirements for flight in this animal, respectively. Wing elasticity measurements suggest that approximately 20% or 0.46 μJ of elastic potential energy cannot be recovered within each half stroke. Local strain energy increases from tip to root, matching the distribution of the wing's elastic protein resilin, whereas local strain energy density varies little in the spanwise direction. This study demonstrates a source of mechanical energy loss in fly flight owing to spanwise wing bending at the stroke reversals, even in cases in which aerodynamic power exceeds inertial power. Despite lower stiffness estimates, our findings are widely consistent with previous stiffness measurements on insect wings but highlight the relationship between local flexural stiffness, wing deformation power and energy expenditure in flapping insect wings.
Effect of CNT addition on cure kinetics of glass fiber/epoxy composite
NASA Astrophysics Data System (ADS)
Fulmali, A. O.; Kattaguri, R.; Mahato, K. K.; Prusty, R. K.; Ray, B. C.
2018-03-01
In present time, developments in reinforced polymer composites have acquired preferential attention for high performance and high precision applications like aerospace, marine and transportation. Fibre reinforced polymer (FRP) composites are being substituted because of their low density, higher strength, stiffness, impact resistance, and improved corrosion resistance. Further laminated composites exhibit superior in-plane mechanical properties that are mostly governed by the fibers. However, laminated FRP composites suffer from poor out of plane properties in some applications. These properties can further be improved by the addition of Nano fillers like carbon nanotube (CNT), graphene and so on. Curing cycle plays a very important role in drawing out the optimum property of glass fiber/epoxy (GE) composite. It is expected that the cure kinetics can further be altered by addition of CNT due to its higher aspect ratio. The main objective of this work is to study the effect of CNT addition on cure kinetics of GE composite as multi-segment adsorption of polymer takes place on the CNT surface. In this study effects of curing parameters on mechanical properties and glass transition temperature of CNT embedded glass fiber/epoxy composite (CNT-GE) has been evaluated. For this study control GE and CNT-GE (with 0.1 wt. %) laminates were fabricated using hand lay-up technique followed by hot compression. The curing parameters that were considered in the present investigation were temperature (80°C, 110°C, and 140°C) and time (0.5 hr, 3 hr and 6 hr). For different combination of above mentioned temperature and time, samples of GE and CNT-GE composites were post cured. Mechanical properties were determined by flexural testing using 3 point bending fixture on INSTRON-5967 and thermal properties i.e. glass transition temperature (Tg) determined by Differential Scanning Calorimeter (DSC) to evaluate the effects of curing parameters. For CNT-GE samples, No much variation observed in flexural modulus with increase in post curing temperature and time, but swift increment was observed in flexural strength at 140°C with increase in post cure time. Elevation in Tg observed with increase in temperature and time duration of post curing; highest Tg noted at 140°C-6hr. Optimum post curing parameters for CNT-GE composite observed to be 140°C-6hr.
NASA Technical Reports Server (NTRS)
Mahfuz, Hassan; Das, Partha S.; Xue, Dongwei; Krishnagopalan, Jaya; Jeelani, Shaik
1993-01-01
Response of quasi-isotropic laminates of SiC coated Carbon/Carbon (C/C) composites have been investigated under flexural loading at various temperatures. Variation of load-deflection behavior with temperatures are studied. Increase in flexural strength and stiffness are observed with the rise in temperature. Extensive analyses through Optical Microscope (OM) and Non-Destructive Evaluation (NDE) have been performed to understand the failure mechanisms. Damage zone is found only within the neighborhood of the loading plane. Isoparametric layered shell elements developed on the basis of the first order shear deformation theory have been used to model the thin laminates of C/C under flexural loading. Large deformation behavior has been considered in the finite element analysis to account for the non-linearities encountered during the actual test. Data generated using finite element analysis are presented to corroborate the experimental findings, and a comparison in respect of displacement and stress-strain behavior are given to check the accuracy of the finite element analysis. Reasonable correlation between the experimental and finite element results have been established.
Design of a flexure mount for optics in dynamic and cryogenic environments
NASA Technical Reports Server (NTRS)
Pollard, Lloyd Wayne
1989-01-01
The design of a flexure mount for a mirror operating in a cryogenic environment is presented. This structure represents a design effort recently submitted to NASA Ames for the support of the primary mirror of the Space Infrared Telescope Facility (SIRTF). The support structure must passively accommodate the differential thermal contraction between the glass mirror and the aluminium structure of the telescope during cryogenic cooldown. Further, it must support the one meter diameter, 116 kilogram (258 pound) primary mirror during a severe launch to orbit without exceeding the micro-yield of the material anywhere in the flexure mount. Procedures used to establish the maximum allowable radial stiffness of the flexural mount, based on the finite element program NASTRAN and the optical program FRINGE, are discussed. Early design concepts were evaluated using a parametric design program, and the development of that program is presented. Dynamic loading analyses performed with NASTRAN are discussed. Methods of combining modal responses resulting from a displacement response spectrum analysis are discussed, and a combination scheme called MRSS, modified root of sum of squares, is presented. Model combination schemes using MRSS, SRSS, and ABS are compared to the results of the modal frequency response analysis performed with NASTRAN.
Plate equations for piezoelectrically actuated flexural mode ultrasound transducers.
Perçin, Gökhan
2003-01-01
This paper considers variational methods to derive two-dimensional plate equations for piezoelectrically actuated flexural mode ultrasound transducers. In the absence of analytical expressions for the equivalent circuit parameters of a flexural mode transducer, it is difficult to calculate its optimal parameters and dimensions, and to choose suitable materials. The influence of coupling between flexural and extensional deformation, and coupling between the structure and the acoustic volume on the dynamic response of piezoelectrically actuated flexural mode transducer is analyzed using variational methods. Variational methods are applied to derive two-dimensional plate equations for the transducer, and to calculate the coupled electromechanical field variables. In these methods, the variations across the thickness direction vanish by using the stress resultants. Thus, two-dimensional plate equations for a stepwise laminated circular plate are obtained.
Spoon, Corrie; Grant, Wally
2011-01-01
Vestibular hair cell bundles in the inner ear contain a single kinocilium composed of a 9+2 microtubule structure. Kinocilia play a crucial role in transmitting movement of the overlying mass, otoconial membrane or cupula to the mechanotransducing portion of the hair cell bundle. Little is known regarding the mechanical deformation properties of the kinocilium. Using a force-deflection technique, we measured two important mechanical properties of kinocilia in the utricle of a turtle, Trachemys (Pseudemys) scripta elegans. First, we measured the stiffness of kinocilia with different heights. These kinocilia were assumed to be homogenous cylindrical rods and were modeled as both isotropic Euler–Bernoulli beams and transversely isotropic Timoshenko beams. Two mechanical properties of the kinocilia were derived from the beam analysis: flexural rigidity (EI) and shear rigidity (kGA). The Timoshenko model produced a better fit to the experimental data, predicting EI=10,400 pN μm2 and kGA=247 pN. Assuming a homogenous rod, the shear modulus (G=1.9 kPa) was four orders of magnitude less than Young's modulus (E=14.1 MPa), indicating that significant shear deformation occurs within deflected kinocilia. When analyzed as an Euler–Bernoulli beam, which neglects translational shear, EI increased linearly with kinocilium height, giving underestimates of EI for shorter kinocilia. Second, we measured the rotational stiffness of the kinocilium insertion (κ) into the hair cell's apical surface. Following BAPTA treatment to break the kinocilial links, the kinocilia remained upright, and κ was measured as 177±47 pN μm rad–1. The mechanical parameters we quantified are important for understanding how forces arising from head movement are transduced and encoded by hair cells. PMID:21307074
Hysteretic Models Considering Axial-Shear-Flexure Interaction
NASA Astrophysics Data System (ADS)
Ceresa, Paola; Negrisoli, Giorgio
2017-10-01
Most of the existing numerical models implemented in finite element (FE) software, at the current state of the art, are not capable to describe, with enough reliability, the interaction between axial, shear and flexural actions under cyclic loading (e.g. seismic actions), neglecting crucial effects for predicting the nature of the collapse of reinforced concrete (RC) structural elements. Just a few existing 3D volume models or fibre beam models can lead to a quite accurate response, but they are still computationally inefficient for typical applications in earthquake engineering and also characterized by very complex formulation. Thus, discrete models with lumped plasticity hinges may be the preferred choice for modelling the hysteretic behaviour due to cyclic loading conditions, in particular with reference to its implementation in a commercial software package. These considerations lead to this research work focused on the development of a model for RC beam-column elements able to consider degradation effects and interaction between the actions under cyclic loading conditions. In order to develop a model for a general 3D discrete hinge element able to take into account the axial-shear-flexural interaction, it is necessary to provide an implementation which involves a corrector-predictor iterative scheme. Furthermore, a reliable constitutive model based on damage plasticity theory is formulated and implemented for its numerical validation. Aim of this research work is to provide the formulation of a numerical model, which will allow implementation within a FE software package for nonlinear cyclic analysis of RC structural members. The developed model accounts for stiffness degradation effect and stiffness recovery for loading reversal.
R. C. Moody; Billy Bohannan
1970-01-01
To establish the effect of using modulus elasticity in addition to visual grade as criteria for the positioning of laminations in laminated beams, an experimental study on southern pine members was conducted. The beams were manufactured in accordance with current specifications for glued-laminated southern pine timber, except that (a) minimum-quality tension...
Commentary on factors affecting transverse vibration using an idealized theoretical equation
Joseph F. Murphy
2000-01-01
An idealized theoretical equation to calculate flexural stiffness using transverse vibration of a simply end-supported beam is being considered by the American Society of Testing and Materials (ASTM) Wood Committee D07 to determine lumber modulus of elasticity. This commentary provides the user a quantitative view of six factors that affect the accuracy of using the...
NASA Astrophysics Data System (ADS)
Li, Xiaopeng; Chen, Yangyang; Hu, Gengkai; Huang, Guoliang
2018-04-01
Designing lightweight materials and/or structures for broadband low-frequency noise/vibration mitigation is an issue of fundamental importance both practically and theoretically. In this paper, by leveraging the concept of frequency-dependent effective stiffness control, we numerically and experimentally demonstrate, for the first time, a self-adaptive metamaterial beam with digital circuit controlled mechanical resonators for strong and broadband flexural wave attenuation at subwavelength scales. The digital controllers that are capable of feedback control of piezoelectric shunts are integrated into mechanical resonators in the metamaterial, and the transfer function is semi-analytically determined to realize an effective bending stiffness in a quadratic function of the wave frequency for adaptive band gaps. The digital as well as analog control circuits as the backbone of the system are experimentally realized with the guarantee stability of the whole electromechanical system in whole frequency regions, which is the most challenging problem so far. Our experimental results are in good agreement with numerical predictions and demonstrate the strong wave attenuation in almost a three times larger frequency region over the bandwidth of a passive metamaterial. The proposed metamaterial could be applied in a range of applications in the design of elastic wave control devices.
Probabilistic Flexural Fatigue in Plain and Fiber-Reinforced Concrete
Ríos, José D.
2017-01-01
The objective of this work is two-fold. First, we attempt to fit the experimental data on the flexural fatigue of plain and fiber-reinforced concrete with a probabilistic model (Saucedo, Yu, Medeiros, Zhang and Ruiz, Int. J. Fatigue, 2013, 48, 308–318). This model was validated for compressive fatigue at various loading frequencies, but not for flexural fatigue. Since the model is probabilistic, it is not necessarily related to the specific mechanism of fatigue damage, but rather generically explains the fatigue distribution in concrete (plain or reinforced with fibers) for damage under compression, tension or flexion. In this work, more than 100 series of flexural fatigue tests in the literature are fit with excellent results. Since the distribution of monotonic tests was not available in the majority of cases, a two-step procedure is established to estimate the model parameters based solely on fatigue tests. The coefficient of regression was more than 0.90 except for particular cases where not all tests were strictly performed under the same loading conditions, which confirms the applicability of the model to flexural fatigue data analysis. Moreover, the model parameters are closely related to fatigue performance, which demonstrates the predictive capacity of the model. For instance, the scale parameter is related to flexural strength, which improves with the addition of fibers. Similarly, fiber increases the scattering of fatigue life, which is reflected by the decreasing shape parameter. PMID:28773123
Probabilistic Flexural Fatigue in Plain and Fiber-Reinforced Concrete.
Ríos, José D; Cifuentes, Héctor; Yu, Rena C; Ruiz, Gonzalo
2017-07-07
The objective of this work is two-fold. First, we attempt to fit the experimental data on the flexural fatigue of plain and fiber-reinforced concrete with a probabilistic model (Saucedo, Yu, Medeiros, Zhang and Ruiz, Int. J. Fatigue, 2013, 48, 308-318). This model was validated for compressive fatigue at various loading frequencies, but not for flexural fatigue. Since the model is probabilistic, it is not necessarily related to the specific mechanism of fatigue damage, but rather generically explains the fatigue distribution in concrete (plain or reinforced with fibers) for damage under compression, tension or flexion. In this work, more than 100 series of flexural fatigue tests in the literature are fit with excellent results. Since the distribution of monotonic tests was not available in the majority of cases, a two-step procedure is established to estimate the model parameters based solely on fatigue tests. The coefficient of regression was more than 0.90 except for particular cases where not all tests were strictly performed under the same loading conditions, which confirms the applicability of the model to flexural fatigue data analysis. Moreover, the model parameters are closely related to fatigue performance, which demonstrates the predictive capacity of the model. For instance, the scale parameter is related to flexural strength, which improves with the addition of fibers. Similarly, fiber increases the scattering of fatigue life, which is reflected by the decreasing shape parameter.
NASA Astrophysics Data System (ADS)
Martini, R.; Barthelat, F.
2016-07-01
Flexible natural armors from fish, alligators or armadillo are attracting an increasing amount of attention from their unique and attractive combinations of hardness, flexibility and light weight. In particular, the extreme contrast of stiffness between hard plates and surrounding soft tissues give rise to unusual and attractive mechanisms, which now serve as model for the design of bio-inspired armors. Despite a growing interest in bio-inspired flexible protection, there is little guidelines as to the choice of materials, optimum thickness, size, shape and arrangement for the protective plates. In this work, we focus on a failure mode we recently observed on natural and bio-inspired scaled armors: the unstable tilting of individual scales subjected to off-centered point forces. We first present a series of experiments on this system, followed by a model based on contact mechanics and friction. We condense the result into a single stability diagram which capture the key parameters that govern the onset of plate tilting from a localized force. We found that the stability of individual plates is governed by the location of the point force on the plate, by the friction at the surface of the plate, by the size of the plate and by the stiffness of the substrate. We finally discuss how some of these parameters can be optimized at the design stage to produce bio-inspired protective systems with desired combination of surface hardness, stability and flexural compliance.
Ahmad, Rohana; Morgano, Steven M; Wu, Benjamin M; Giordano, Russell A
2005-11-01
Many studies on the strengthening effects of grinding and polishing, as well as heat treatment on ceramics, are not well standardized or use commercially available industrial polishing systems. The reported effectiveness of these strengthening mechanisms on ceramics may not be applicable to clinical dentistry. The purpose of this study was to evaluate the effects of controlled polishing on the flexural strength of dental ceramics by using a custom-made machine that applied standardized loads and speeds that coincided with the mean loads and speeds used by experienced prosthodontists. A total of 140 aluminous dental ceramic bar-shaped specimens (Vitadur Alpha Enamel) measuring 1.5 x 2.0 x 25 mm were fabricated and divided into 12 groups (for most groups, n=10). Specimens were untreated, polished with different polishing systems, polished at different speeds, ground and autoglazed, polished and autoglazed, autoglazed and polished, polished with loose (paste) and bonded abrasives, or overglazed. Simulated clinical polishing was performed on the ceramic specimens by using a customized polishing apparatus that allowed independent control over the relevant polishing parameters (abrasive hardness, applied load, linear speed, rotational velocity, and wheel stiffness). Flexural strength (MPa) was measured with a 4-point bending test, and subjective surface roughness was assessed with scanning electron microscopy. Autoglazing was performed at various stages of the polishing sequence to determine the effects of polishing on surface stresses. Mean values, standard deviations, independent-sample t tests, 1-way and 2-way analyses of variance, Dunnett t tests and Kruskal-Wallis tests were applied to the data (alpha=.05). Under a clinical load of 0.6 N for a coarse polishing wheel, 1.0 N for a medium polishing wheel, and 1.3 N for a fine polishing wheel, a linear speed of 499 mm/min, and a rotational velocity of 10,000 rpm, the use of clinical polishing instruments did not affect the flexural strength of the aluminous ceramics studied (P=.274). At higher rotational velocity (20,000 rpm), specimens polished with the diamond polishing system produced statistically weaker specimens compared with those that had been polished at 10,000 rpm (P=.019). Autoglazing treatment of the diamond-polished specimens did not reverse the strength degradation (P=.125). Conversely, diamond polishing of the autoglazed specimens resulted in significant flexural strength reduction (P=.029). Fine-diamond-bonded abrasive significantly reduced flexural strength (P=.025). Simulated clinical polishing at 10,000 rpm did not appear to substantially strengthen or weaken the ceramic specimens. Polishing at 20,000 rpm reduced flexural strength of the ceramic bars.
Xiping Wang; James P. Wacker; Robert J. Ross; Brian K. Brashaw; Robert Vatalaro
2005-01-01
This paper describes an effort to develop a global dynamic testing technique for evaluating the overall stiffness of timber bridge superstructures. A forced vibration method was used to measure the natural frequency of single-span timber bridges in the laboratory and field. An analytical model based on simple beam theory was proposed to represent the relationship...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vaughn, Mark R.; Montague, Stephen
A push plate that includes springs in the form of cantilever flexures and an inspection window is disclosed. The push plate provides a known, uniform, down force and minimal torque to a package to be tested. The cantilevers have a known, calculable down force producing stiffness. The window provides for viewing of the package during testing.
Determination of Elastic Moduli of Fiber-Resin Composites Using an Impulse Excitation Technique
NASA Technical Reports Server (NTRS)
Viens, Michael J.; Johnson, Jeffrey J.
1996-01-01
The elastic moduli of graphite/epoxy and graphite/cyanate ester composite specimens with various laminate lay-ups was determined using an impulse excitation/acoustic resonance technique and compared to those determined using traditional strain gauge and extensometer techniques. The stiffness results were also compared to those predicted from laminate theory using uniaxial properties. The specimen stiffnesses interrogated ranged from 12 to 30 Msi. The impulse excitation technique was found to be a relatively quick and accurate method for determining elastic moduli with minimal specimen preparation and no requirement for mechanical loading frames. The results of this investigation showed good correlation between the elastic modulus determined using the impulse excitation technique, strain gauge and extensometer techniques, and modulus predicted from laminate theory. The flexural stiffness determined using the impulse excitation was in good agreement with that predicted from laminate theory. The impulse excitation/acoustic resonance interrogation technique has potential as a quality control test.
Modelling the behaviour of steel fibre reinforced precast beam-to-column connection
NASA Astrophysics Data System (ADS)
Chai, C. E.; Sarbini, NN; Ibrahim, I. S.; Ma, C. K.; Tajol Anuar, M. Z.
2017-11-01
The numerical behaviour of steel fibre reinforced concrete (SFRC) corbels reinforced with different fibre volume ratio subjected to vertical incremental load is presented in this paper. Precast concrete structures had become popular in the construction field, which offer a faster, neater, safer, easier and cheaper construction work. The construction components are prefabricated in controlled environment under strict supervision before being erected on site. However, precast beam-column connections are prone to failure due to the brittle properties of concrete. Finite element analysis (FEA) is adopted due to the nonlinear behaviour of concrete and SFRC. The key objective of this research is to develop a reliable nonlinear FEA model to represent the behaviour of reinforced concrete corbel. The developed model is validated with experimental data from previous researches. Then, the validated FEA model is used to predict the behaviour of SFRC corbel reinforced with different fibre volume ratio by changing the material parameters. The results show that the addition of steel fibre (SF) increases the load carrying capacity, ductility, stiffness, and changed the failure mode of corbel from brittle bending-shear to flexural ductile. On the other hand, the increasing of SF volume ratio also leads to increased load carrying capacity, ductility, and stiffness of corbel.
Dynamics of a flexible splitter plate in the wake of a circular cylinder
NASA Astrophysics Data System (ADS)
Shukla, S.; Govardhan, R. N.; Arakeri, J. H.
2013-08-01
Rigid splitter plates in the wake of bluff bodies are known to suppress the primary vortex shedding. In the present work, we experimentally study the problem of a flexible splitter plate in the wake of a circular cylinder. In this case, the splitter plate is free to continuously deform along its length due to the fluid forces acting on it; the flexural rigidity (EI) of the plate being an important parameter. Direct visualizations of the splitter plate motions, for very low values of flexural rigidity (EI), indicate periodic traveling wave type deformations of the splitter plate with maximum tip amplitudes of the order of 1 cylinder diameter. As the Reynolds number based on cylinder diameter is varied, two regimes of periodic splitter plate motions are found that are referred to as mode I and mode II, with a regime of aperiodic motions between them. The frequency of plate motions in both periodic modes is found to be close to the plane cylinder Strouhal number of about 0.2, while the average frequencies in the non-periodic regime are substantially lower. The measured normalized phase speed of the traveling wave for both periodic modes is also close to the convection speed of vortices in the plane cylinder wake. As the flexural rigidity of the plate (EI) is increased, the response of the plate was found to shift to the right when plotted with flow speed or Re. To better capture the effect of varying EI, we define and use a non-dimensional bending stiffness, K*, similar to the ones used in the flag flutter problem, K=EI/(0.5ρUL), where U is the free-stream velocity and L is the splitter plate length. Amplitude data for different EI cases when plotted against this parameter appear to collapse on to a single curve for a given splitter plate length. Measurements of the splitter plate motions for varying splitter plate lengths indicate that plates that are substantially larger than the formation length of the plane cylinder wake have similar responses, while shorter plates show significant differences.
Effects of slag on flexural strength of slurry infiltrated fibrous concrete
NASA Astrophysics Data System (ADS)
Elavarasi, D.; Saravana Raja Mohan, K.; Parthasarathy, P.; Dinesh, T.
2017-07-01
Slurry infiltrated fibrous concrete is one of the new advanced concrete composite which differs from method of fabrication and composition of the matrix. Extensive research is being carried out on alternative binders or supplements to cement aiming to reduce environmental impact. However, little has been published to investigate the structural behaviour of SIFCON incorporating with mineral admixtures, particularly as regards its ultrahigh ductility, which may alter the mode of failure from brittle to the more desirable ductile. An experimental study was carried out to investigate the flexural behavior of SIFCON containing three different percentage of fibre content 6%,8% &10% with incorporation of optimum dosage of blast furnace slag replaced by cement. Strength characteristics such as Compressive strength and splitting tensile strength test were carry out for SIFCON incorporating 10% of fibre content and different percentage of slag (0, 15, 30, 45, 60%&75%) to optimize the replacement level. The test results found that the maximum strengths were attained at 30% of blast furnace slag replaced by cement. To study the flexural behavior of SIFCON beam of size 1.2x0.1x0.2m containing different percentages (6%, 8% & 10%) fibre content incorporating with and without the optimum percentage of slag were cast and tested. Both flexural strength and Load displacement characteristics of the specimens were studied under flexure. The outcomespresentedfromtest resultshave been compared. The test results reveals that the flexural strength, toughness, ductility and stiffness characteristics were significantly improved due to incorporation of optimum dosage of slag enhancing when compared to without mineral admixtures also compared to conventional concrete(RCC). Major conclusions were drawn from the investigations which are presented.
NASA Astrophysics Data System (ADS)
Mao, Chenxi; Dong, Jinzhi; Li, Hui; Ou, Jinping
2012-04-01
Shear wall system is widely adopted in high rise buildings because of its high lateral stiffness in resisting earthquakes. According to the concept of ductility seismic design, coupling beams in shear wall structure are required to yield prior to the damage of wall limb. However, damage in coupling beams results in repair cost post earthquake and even in some cases it is difficult to repair the coupling beams if the damage is severe. In order to solve this problem, a novel passive SMA damper was proposed in this study. The coupling beams connecting wall limbs are split in the middle, and the dampers are installed between the ends of the two cantilevers. Then the relative flexural deformation of the wall limbs is transferred to the ends of coupling beams and then to the SMA dampers. After earthquakes the deformation of the dampers can recover automatically because of the pseudoelasticity of austenite SMA material. In order to verify the validity of the proposed dampers, seismic responses of a 12-story coupled shear wall with such passive SMA dampers in coupling beams was investigated. The additional stiffness and yielding deformation of the dampers and their ratios to the lateral stiffness and yielding displacements of the wall limbs are key design parameters and were addressed. Analytical results indicate that the displacement responses of the shear wall structure with such dampers are reduced remarkably. The deformation of the structure is concentrated in the dampers and the damage of coupling beams is reduced.
The flexural stiffness and tension state of basalt filter
NASA Astrophysics Data System (ADS)
Khalmuradovich, Sattarov Laziz; Ahmedovich, Kurbanov Abdirahim
2017-03-01
In recent years, there is a growing demand in Uzbekistan for new, cheap and competitive products from local raw materials, the demand being directly connected with the expansion and development opportunities of the mining, metallurgical and processing industries. In such conditions, the need for providing a solution of the problems faced by these industries is a very urgent one and requires further comprehensive studies. One of these tasks includes assessment of the force parameters and bending stiffness of basalt fibre filters, aimed at further improving the efficiency of local basalt raw materials and aiding in the manufacture of new, long-lasting, reliable and high-quality products. In this case, we studied the interaction of basalt fibre filter with a gas or liquid medium, the deformed state of the fibres under the action force of the gas or liquid, and the filter recovery process after removal of the load, all of which occur during mechanical filtration. These tasks are of interest because during the mechanical filtration of a gas or liquid (hereinafter, mechanical filtration) from solids, all attention is paid to the quality of the filtering process. The filtering quality, as known, is determined by the degree of contamination in the liquid undergoing treatment, duration of separation of the pulp into solid and liquid phases during the decantation process of the mixture and the amount of gas/ liquid released into the atmosphere along with carbon monoxide and toxic impurities. At the same time, the state and behaviour of the filtering material remain as minor factors, the consideration of which can play a decisive role in the establishment of filter life and work capacity. Solutions to these problems are very urgent and allow one to create new technologies for the production of basalt filters based on force parameters and bending stiffness, wherein the purification occurs without the intervention of chemicals.
Using Composites in Seismic Retrofit Applications
2005-04-20
precast concrete segments, or other rigid filler material, with changing radii of curvature in the different loading directions. An...0.17% Ratio Axial Load Ratio P/(f’cAg) 5 to 30% 17.68% Table 6.5: Test Parameters for Rectangular Flexure (Continuous) Columns Parameter Range Fyfe...Ratio Axial Load Ratio P / (fc’Ag) 5 to 30% 14.46% 14.46% 14.46% 16 Table 6. 6. Test Parameters for Circular Flexure (Lap Splice) Columns Parameter
A novel voice coil motor-driven compliant micropositioning stage based on flexure mechanism
NASA Astrophysics Data System (ADS)
Shang, Jiangkun; Tian, Yanling; Li, Zheng; Wang, Fujun; Cai, Kunhai
2015-09-01
This paper presents a 2-degrees of freedom flexure-based micropositioning stage with a flexible decoupling mechanism. The stage is composed of an upper planar stage and four vertical support links to improve the out-of-plane stiffness. The moving platform is driven by two voice coil motors, and thus it has the capability of large working stroke. The upper stage is connected with the base through six double parallel four-bar linkages mechanisms, which are orthogonally arranged to implement the motion decoupling in the x and y directions. The vertical support links with serially connected hook joints are utilized to guarantee good planar motion with heavy-loads. The static stiffness and the dynamic resonant frequencies are obtained based on the theoretical analyses. Finite element analysis is used to investigate the characteristics of the developed stage. Experiments are carried out to validate the established models and the performance of the developed stage. It is noted that the developed stage has the capability of translational motion stroke of 1.8 mm and 1.78 mm in working axes. The maximum coupling errors in the x and y directions are 0.65% and 0.82%, respectively, and the motion resolution is less than 200 nm. The experimental results show that the developed stage has good capability for trajectory tracking.
NASA Astrophysics Data System (ADS)
Ain Hamiruddin, Nur; Razak, Rafiza Abd; Muhammad, Khairunnisa; Zahid, Muhd Zulham Affendi Mohd
2018-04-01
The purpose of this study is to investigate the flexural behaviour of heat damaged reinforced concrete (RC) slab by using High Strength Fibre Reinforced Concrete (HSFRC) as repair materials. The slab samples consist of twelve one-way columns heated at 200 ° C, 400 ° C and 600 ° C for 120 minutes. The thickness of the HSFRC layer used to heat damaged slab samples is 40 mm thick. Two distinct curing methods were implement during this study: i.e. normal curing (standard room temperature 26°C) and heat curing (temperature of 90°C for 48 hours). The center-point loading flexural strength test based on ASTM C 293 were referred to examine the flexural strength of the slab samples other than evaluated the mechanical properties of repaired samples (i.e. flexural strength, secant stiffness, toughness and ductility). The HSFRC's results showed that compressive strength at 28 days was 88.66 MPa. Whereas the flexural strength of heat damage repaired samples that exposed to 200°C (R200), 400°C (RNC400) and 400°C (RHC400) were gained by about 3.06% (34.93 MPa), 14.47% (38.79 MPa) and 30.95% (44.38 MPa) respectively, contrasted to the control sample (CS) which is 33.89 MPa. However, heat damage for non-repaired samples that exposed to 200 ° C (NR200) and 400°C (NR400) decline by about 0.77% (33.63 MPa) and 8.13% (31.14 MPa) respectively. Therefore, the utilized of HSFRC as repair materials can improve the flexural strength than control sample (CS). This is clearly indicate that HSFRC can enhance the mechanical properties of heat damaged reinforced concrete (RC) slab which can illustrate that the results of flexural behaviour reflected the superiority by using HSFRC as repair materials.
Weibull models of fracture strengths and fatigue behavior of dental resins in flexure and shear.
Baran, G R; McCool, J I; Paul, D; Boberick, K; Wunder, S
1998-01-01
In estimating lifetimes of dental restorative materials, it is useful to have available data on the fatigue behavior of these materials. Current efforts at estimation include several untested assumptions related to the equivalence of flaw distributions sampled by shear, tensile, and compressive stresses. Environmental influences on material properties are not accounted for, and it is unclear if fatigue limits exist. In this study, the shear and flexural strengths of three resins used as matrices in dental restorative composite materials were characterized by Weibull parameters. It was found that shear strengths were lower than flexural strengths, liquid sorption had a profound effect on characteristic strengths, and the Weibull shape parameter obtained from shear data differed for some materials from that obtained in flexure. In shear and flexural fatigue, a power law relationship applied for up to 250,000 cycles; no fatigue limits were found, and the data thus imply only one flaw population is responsible for failure. Again, liquid sorption adversely affected strength levels in most materials (decreasing shear strengths and flexural strengths by factors of 2-3) and to a greater extent than did the degree of cure or material chemistry.
Analysis and Load Rating of Pre-flex Composite Beams
2011-09-01
limit is temporary and applies only at the moment the load is removed during the fabrication. Once in service, the allowable compressive stress is...the analysis procedures, the load rating methodology applied in this report is based on the general Equation 19. 1 2 C - (A )(D) RF= (A )L(1+I...construction in order to generate composite beam action and, in turn, increase their flexural capacity and stiffness. With regard to live loads ,
Flexural behaviour of RCC beams with externally bonded FRP
NASA Astrophysics Data System (ADS)
Vignesh, S. Arun; Sumathi, A.; Saravana Raja Mohan, K.
2017-07-01
The increasing use of carbon and glass fibre reinforced polymer (FRP) sheets for strengthening existing reinforced concrete beams has generated considerable interest in understanding the behavior of the FRP sheets when subjected to bending. The study on flexure includes various parameters like percentage of increase in strength of the member due to the externally bonded Fiber reinforced polymer, examining the crack patterns, reasons of debonding of the fibre from the structure, scaling, convenience of using the fibres, cost effectiveness etc. The present work aims to study experimentally about the reasons behind the failure due to flexure of an EB-FRP concrete beam by studying the various parameters. Deflection control may become as important as flexural strength for the design of FRPreinforced concrete structures. A numerical model is created using FEM software and the results are compared with that of the experiment.
Nanographene reinforced carbon/carbon composites
NASA Astrophysics Data System (ADS)
Bansal, Dhruv
Carbon/Carbon Composites (CCC) are made of carbon reinforcement in carbon matrix and have high thermal stability and fatigue resistance. CCC are used in nose cones, heat shields and disc brakes of aircrafts due to their exceptional mechanical properties at high temperature. The manufacturing process of CCC involves a carbonization stage in which unwanted elements, except carbon, are eliminated from the polymer precursor. Carbonization results in the formation of voids and cracks due to the thermal mismatch between the reinforcement and the matrix and expulsion of volatiles from the polymer matrix. Thermal cracks and voids decrease the density and mechanical properties of the manufactured CCC. In this work, Nanographene Platelets (NGP) were explored as nanofillers to fill the voids/cracks and reduce thermal shrinkage in CCC. They were first compared with Vapor Grown Carbon Nanofibers (VGCNF) by dispersion of different concentrations (0.5wt%, 1.5wt%, 3wt%) in resole-type phenolic resin and were characterized to explore their effect on rheology, heat of reaction and wetting behavior. The dispersions were then cured to form nanocomposites and were characterized for morphology, flexure and thermal properties. Finally, NGP were introduced into the carbon/carboncomposites in two stages, first by spraying in different concentrations (0.5wt%, 1.5wt%, 3wt%, 5wt %) during the prepreg formation and later during densification by directly mixing in the corresponding densification mix. The manufactured NGP reinforced CCC were characterized for microstructure, porosity, bulk density and mechanical properties (Flexure and ILSS) which were further cross-checked by non-destructive techniques (vibration and ultrasonic). In this study, it was further found that at low concentration (≤ 1.5 wt%) NGP were more effective in increasing the heat of reaction and in decreasing the viscosity of the phenolic resin. The decrease in viscosity led to better wetting properties of NGP / phenolic dispersions compared to VGCNF/phenolic dispersions. In nanocomposites, at low concentration (≤ 1.5 wt%), NGP were effective in increasing the flexure strength, char content and lowering the porosity and coefficient of thermal expansion of neat phenolic resin. At higher concentration (>1.5wt%), NGP had a tendency to agglomerate and lost their effectiveness. The behavior observed in nanocomposites continued in manufactured CCC. The highest Inter Laminar Shear Strength (ILSS), flexure strength/modulus, stiffness and density was observed at 1.5 wt% NGP. In CCC at concentrations > 1.5 wt%, the properties (ILSS, flexure, stiffness, density) decreased due to agglomeration but they were still higher compared to that of neat CCC (without NGP).
McCullough, Brannon R.; Blanchoin, Laurent; Martiel, Jean-Louis; De La Cruz, Enrique M.
2009-01-01
We determined the flexural (bending) rigidities of actin and cofilactin filaments from a cosine correlation function analysis of their thermally driven, two-dimensional fluctuations in shape. The persistence length of actin filaments is 9.8 µm, corresponding to a flexural rigidity of 0.040 pN µm2. Cofilin binding lowers the persistence length ∼5-fold to a value of 2.2 µm and the filament flexural rigidity to 0.0091 pN µm2. That cofilin-decorated filaments are more flexible than native filaments despite an increased mass indicates that cofilin binding weakens and redistributes stabilizing subunit interactions of filaments. We favor a mechanism in which the increased flexibility of cofilin-decorated filaments results from the linked dissociation of filament-stabilizing ions and reorganization of actin subdomain 2 and as a consequence promotes severing due to a mechanical asymmetry. Knowledge of the effects of cofilin on actin filament bending mechanics, together with our previous analysis of torsional stiffness, provide a quantitative measure of the mechanical changes in actin filaments associated with cofilin binding, and suggest that the overall mechanical and force-producing properties of cells can be modulated by cofilin activity. PMID:18617188
Modeling the growth and branching of plants: A simple rod-based model
NASA Astrophysics Data System (ADS)
Faruk Senan, Nur Adila; O'Reilly, Oliver M.; Tresierras, Timothy N.
A rod-based model for plant growth and branching is developed in this paper. Specifically, Euler's theory of the elastica is modified to accommodate growth and remodeling. In addition, branching is characterized using a configuration force and evolution equations are postulated for the flexural stiffness and intrinsic curvature. The theory is illustrated with examples of multiple static equilibria of a branched plant and the remodeling and tip growth of a plant stem under gravitational loading.
Probing Mechanics of Crumpled Two-Dimensional Membranes and Cantilevers
NASA Astrophysics Data System (ADS)
Nicholl, Ryan; Conley, Hiram; Lavrik, Nickolay; Vlassiouk, Ivan; Puzyrev, Yevgeniy; Sreenivas, Vijayashree Parsi; Pantelides, Sokrates; Bolotin, Kirill
Two-dimensional materials (2DMs) are inevitably crumpled in the out-of-plane direction due to both static wrinkling associated with uneven stresses and dynamic wrinkling resulting from flexural phonons. Here, we investigate the effect of this crumpling on mechanical properties of 2DMs - in-plane stiffness and bending rigidity. To carry out these measurements, we developed techniques to fabricate graphene membranes and singly clamped graphene cantilevers that are stable in vacuum and air. The measurements are performed by actuating these devices electrostatically and monitoring their displacement via sensitive interferometric profilometry both at room and low temperatures. We find that crumpling lowers the in-plane stiffness and strongly increases the bending rigidity of 2DMs. Furthermore, we unravel the relative contribution of static and dynamic wrinkling to observed renormalization of the effective mechanical constants.
Atomic force microscope based on vertical silicon probes
NASA Astrophysics Data System (ADS)
Walter, Benjamin; Mairiaux, Estelle; Faucher, Marc
2017-06-01
A family of silicon micro-sensors for Atomic Force Microscope (AFM) is presented that allows to operate with integrated transducers from medium to high frequencies together with moderate stiffness constants. The sensors are based on Micro-Electro-Mechanical-Systems technology. The vertical design specifically enables a long tip to oscillate perpendicularly to the surface to be imaged. The tip is part of a resonator including quasi-flexural composite beams, and symmetrical transducers that can be used as piezoresistive detector and/or electro-thermal actuator. Two vertical probes (Vprobes) were operated up to 4.3 MHz with stiffness constants 150 N/m to 500 N/m and the capability to oscillate from 10 pm to 90 nm. AFM images of several samples both in amplitude modulation (tapping-mode) and in frequency modulation were obtained.
Comparison of the flexural strength of six reinforced restorative materials.
Cohen, B I; Volovich, Y; Musikant, B L; Deutsch, A S
2001-01-01
This study calculated the flexural strength for six reinforced restorative materials and demonstrated that flexural strength values can be determined simply by using physical parameters (diametral tensile strength and Young's modulus values) that are easily determined experimentally. A one-way ANOVA analysis demonstrated a statistically significant difference between the two reinforced glass ionomers and the four composite resin materials, with the composite resin being stronger than the glass ionomers.
Behavior of composite sandwich panels with several core designs at different impact velocities
NASA Astrophysics Data System (ADS)
Jiga, Gabriel; Stamin, Ştefan; Dinu, Gabriela
2018-02-01
A sandwich composite represents a special class of composite materials that is manufactured by bonding two thin but stiff faces to a low density and low strength but thick core. The distance between the skins given by the core increases the flexural modulus of the panel with a low mass increase, producing an efficient structure able to resist at flexural and buckling loads. The strength of sandwich panels depends on the size of the panel, skins material and number or density of the cells within it. Sandwich composites are used widely in several industries, such as aerospace, automotive, medical and leisure industries. The behavior of composite sandwich panels with different core designs under different impact velocities are analyzed in this paper by numerical simulations performed on sandwich panels. The modeling was done in ANSYS and the analysis was performed through LS-DYNA.
Design and verification of a novel hollow vibrating module for laser machining.
Wang, Zhaozhao; Jang, Seungbong; Kim, EunHee; Jeon, Yongho; Lee, Soo-Hun; Lee, Moon G
2015-04-01
If a vibration module is added on laser machining system, the quality of surface finish and aspect ratio on metals can be significantly enhanced. In this study, a single mobility model of vibrating laser along the path of laser beam was put forward. In order to realize the desired unidirectional motion, a resonance type vibration module with optical lens was designed and manufactured. This cylindrical module was composed of curved-beam flexure elements. The cylindrical coordinate system was established to describe the relationship of a curved-beam flexure element's motion and deformation. In addition, the stiffness matrix of the curved-beam element was obtained. Finite element method and dynamical modeling were provided to analyze the resonance frequency and the displacement of the motion. The feasibility of the design was demonstrated with the help of experiments on frequency response. Experimental results show good agreement with theoretical analysis and simulation predictions.
Monolithic Flexure Pre-Stressed Ultrasonic Horns
NASA Technical Reports Server (NTRS)
Sherrit, Stewart; Bao, Xiaoqi; Badescu, Mircea; Bar-Cohen, Yoseph; Allen, Phillip Grant
2011-01-01
High-power ultrasonic actuators are generally assembled with a horn, backing, stress bolt, piezoelectric rings, and electrodes. The manufacturing process is complex, expensive, difficult, and time-consuming. The internal stress bolt needs to be insulated and presents a potential internal discharge point, which can decrease actuator life. Also, the introduction of a center hole for the bolt causes many failures, reducing the throughput of the manufactured actuators. A new design has been developed for producing ultrasonic horn actuators. This design consists of using flexures rather than stress bolts, allowing one to apply pre-load to the piezoelectric material. It also allows one to manufacture them from a single material/plate, rapid prototype them, or make an array in a plate or 3D structure. The actuator is easily assembled, and application of pre-stress greater than 25 MPa was demonstrated. The horn consists of external flexures that eliminate the need for the conventional stress bolt internal to the piezoelectric, and reduces the related complexity. The stress bolts are required in existing horns to provide prestress on piezoelectric stacks when driven at high power levels. In addition, the manufacturing process benefits from the amenability to produce horn structures with internal cavities. The removal of the pre-stress bolt removes a potential internal electric discharge point in the actuator. In addition, it significantly reduces the chances of mechanical failure in the piezoelectric stacks that result from the hole surface in conventional piezoelectric actuators. The novel features of this disclosure are: 1. A design that can be manufactured from a single piece of metal using EDM, precision machining, or rapid prototyping. 2. Increased electromechanical coupling of the horn actuator. 3. Higher energy density. 4. A monolithic structure of a horn that consists of an external flexure or flexures that can be used to pre-stress a solid piezoelectric structure rather than a bolt, which requires a through hole in the piezoelectric material. 5. A flexure system with low stiffness that accommodates mechanical creep with minor reduction in pre-stress.
The Use of Doublers in Delamination Toughness Testing
NASA Technical Reports Server (NTRS)
Reeder, James R.; Demarco, Kevin; Whitley, Karen S.
2002-01-01
In this paper, the data reduction equations for common delamination toughness tests are rederived for use with specimens which have bonded doublers. The common toughness tests considered here are the double cantilever beam (DCB) for mode I toughness; the end notch flexure (3ENF) and 4 point ENF (4ENF) for mode II toughness; and the mixed mode bending (MMB) test for testing under combined mode I and mode II loading. Because the addition of the doublers changes the bending stiffness of the specimens, these data reduction equations may need to be corrected. Doublers were added to the delamination test specimens to solve a premature failure problem. Delamination toughness is normally tested using a beam with an imbedded insert so that one end of the specimen is split into two arms. If the specimen is too thin, or if the toughness of the material is too high, an arm of the specimen may fail in bending before the delamination grows. When this occurs, the toughness of the material cannot be determined. To delay the bending failure so that delamination growth occurs, doubler plates were bonded to both top and bottom surfaces of the specimen. A doubler parameter, beta, which describes how much the use of doubler plates changed the ratio of full thickness to delaminated bending stiffnesses, was defined. When changes to the data reduction equations were required, the changes were minor when written in terms of the beta parameter. The doubler plate technique was demonstrated by measuring the mixed-mode fracture toughness of a carbon-carbon composite using test specimens which would otherwise have failed before delamination growth occurred. The doubler plate technique may solve several problems that can be encountered when testing delamination fracture toughness.
NASA Technical Reports Server (NTRS)
Chio, S. R.; Gyekenyesi, J. P.
1999-01-01
A two-dimensional, numerical analysis of slow crack growth (SCG) was performed for brittle materials with finite thickness subjected to constant stress-rate ("dynamic fatigue") loading in flexure. The numerical solution showed that the conventional, simple, one-dimensional analytical solution can be used with a maximum error of about 5% in determining the SCG parameters of a brittle material with the conditions of a normalized thickness (a ratio of specimen thickness to initial crack size) T > 3.3 and of a SCG parameter n > 10. The change in crack shape from semicircular to elliptical configurations was significant particularly at both low stress rate and low T, attributed to predominant difference in stress intensity factor along the crack front. The numerical solution of SCG parameters was supported within the experimental range by the data obtained from constant stress-rate flexural testing for soda-lime glass microslides at ambient temperature.
NASA Astrophysics Data System (ADS)
Contreras-Reyes, Eduardo; Garay, Jeremías
2018-01-01
The outer rise is a topographic bulge seaward of the trench at a subduction zone that is caused by bending and flexure of the oceanic lithosphere as subduction commences. The classic model of the flexure of oceanic lithosphere w (x) is a hydrostatic restoring force acting upon an elastic plate at the trench axis. The governing parameters are elastic thickness Te, shear force V0, and bending moment M0. V0 and M0 are unknown variables that are typically replaced by other quantities such as the height of the fore-bulge, wb, and the half-width of the fore-bulge, (xb - xo). However, this method is difficult to implement with the presence of excessive topographic noise around the bulge of the outer rise. Here, we present an alternative method to the classic model, in which lithospheric flexure w (x) is a function of the flexure at the trench axis w0, the initial dip angle of subduction β0, and the elastic thickness Te. In this investigation, we apply a sensitivity analysis to both methods in order to determine the impact of the differing parameters on the solution, w (x). The parametric sensitivity analysis suggests that stable solutions for the alternative approach requires relatively low β0 values (<15°), which are consistent with the initial dip angles observed in seismic velocity-depth models across convergent margins worldwide. The predicted flexure for both methods are compared with observed bathymetric profiles across the Izu-Mariana trench, where the old and cold Pacific plate is characterized by a pronounced outer rise bulge. The alternative method is a more suitable approach, assuming that accurate geometric information at the trench axis (i.e., w0 and β0) is available.
Roberts, Cynthia J; Mahmoud, Ashraf M; Bons, Jeffrey P; Hossain, Arif; Elsheikh, Ahmed; Vinciguerra, Riccardo; Vinciguerra, Paolo; Ambrósio, Renato
2017-04-01
To investigate two new stiffness parameters and their relationships with the dynamic corneal response (DCR) parameters and compare normal and keratoconic eyes. Stiffness parameters are defined as Resultant Pressure at inward applanation (A1) divided by corneal displacement. Stiffness parameter A1 uses displacement between the undeformed cornea and A1 and stiffness parameter highest concavity (HC) uses displacement from A1 to maximum deflection during HC. The spatial and temporal profiles of the Corvis ST (Oculus Optikgeräte, Wetzlar, Germany) air puff were characterized using hot wire anemometry. An adjusted air pressure impinging on the cornea at A1 (adjAP1) and an algorithm to biomechanically correct intraocular pressure based on finite element modelling (bIOP) were used for Resultant Pressure calculation (adjAP1 - bIOP). Linear regression analyses between DCR parameters and stiffness parameters were performed on a retrospective dataset of 180 keratoconic eyes and 482 normal eyes. DCR parameters from a subset of 158 eyes of 158 patients in each group were matched for bIOP and compared using t tests. A P value of less than .05 was considered statistically significant. All DCR parameters evaluated showed significant differences between normal and keratoconic eyes, except peak distance. Keratoconic eyes had lower stiffness parameter values, thinner pachymetry, shorter applanation lengths, greater absolute values of applanation velocities, earlier A1 times and later second applanation times, greater HC deformation amplitudes and HC deflection amplitudes, and lower HC radius of concave curvature (greater concave curvature). Most DCR parameters showed a significant relationship with both stiffness parameters in both groups. Keratoconic eyes demonstrated less resistance to deformation than normal eyes with similar IOP. The stiffness parameters may be useful in future biomechanical studies as potential biomarkers. [J Refract Surg. 2017;33(4):266-273.]. Copyright 2017, SLACK Incorporated.
NASA Astrophysics Data System (ADS)
Tomo, H. S. S.; Ujianto, O.; Rizal, R.; Pratama, Y.
2017-07-01
Composite material thermoplastic was prepared from polypropilen granule as matrix, kenaf fiber as reinforcement and grafted polypropylene copolymer maleic anhydride as coupling agent. Composite products were produced as sandwich structures using compression molding. This research aimed to observe the influence of number of ply, temperature, pressure, and compression time using factorial design. Effects of variables on tensile and flexural strength were analyzed. Experimental results showed that tensile and flexural strength were influenced by degradation, fiber compaction, and matrix - fiber interaction mechanisms. Flexural strength was significantly affected by number of ply and its interaction to another process parameters (temperature, pressure, and compression time), but no significant effect of process parameters on tensile strength. The highest tensile strength (62.0 MPa) was produced at 3 ply, 210 °C, 50 Bar, and 3 min compression time (low, high, high, low), while the highest flexural strength (80.3 MPa) was produced at 3 ply, 190 °C, 50 Bar, and 3 min compression time (low, low, high, low).
NASA Technical Reports Server (NTRS)
Choi, Sung R.; Powers, Lynn M.; Nemeth, Noel N.
2000-01-01
Extensive constant stress-rate testing for 96 wt % alumina was conducted in room-temperature distilled water using four different specimen/loading configurations: rectangular beam test specimens under four-point uniaxial flexure, square plate test specimens in ring-on-ring biaxial flexure, square plate test specimens in ball-on-ring biaxial flexure, and dog-boned tensile test specimens in pure tension. The slow crack growth (SCG) parameter n was almost independent of specimen/loading configurations, in either four-point uniaxial flexure, ring-on-ring biaxial flexure, ball-on-ring biaxial flexure, or pure tension, ranging from n = 35 to 47 with an average value of n = 41.1 +/- 4.5. The prediction of fatigue strength/reliability based on the four-point uniaxial flexure data by using the CARES/Life design code as well as a simple PIA model was in good agreement with both the ring-on-ring biaxial and the ball-on-ring biaxial flexure data. A poor prediction using the PIA model was observed for the dog-boned tensile test specimens, presumably due to different flaw population involved in the tensile test specimens.
NASA Astrophysics Data System (ADS)
Patel, Namu; Patankar, Neelesh A.
2017-11-01
Aquatic locomotion relies on feedback loops to generate the flexural muscle moment needed to attain the reference shape. Experimentalists have consistently reported a difference between the electromyogram (EMG) and curvature wave speeds. The EMG wave speed has been found to correlate with the cross-sectional moment wave. The correlation, however, remains unexplained. Using feedback dependent controller models, we demonstrate two scenarios - one at higher passive elastic stiffness and another at lower passive elastic stiffness of the body. The former case becomes equivalent to the penalty type mathematical model for swimming used in prior literature and it does not reproduce neuromechanical wave speed discrepancy. The latter case at lower elastic stiffness does reproduce the wave speed discrepancy and appears to be biologically most relevant. These findings are applied to develop testable hypotheses about control mechanisms that animals might be using at during low and high Reynolds number swimming. This work is supported by NSF Grants DMS-1547394, CBET-1066575, ACI-1460334, and IOS-1456830. Travel for NP is supported by Institute for Defense Analyses.
A one-piece 3D printed flexure translation stage for open-source microscopy
NASA Astrophysics Data System (ADS)
Sharkey, James P.; Foo, Darryl C. W.; Kabla, Alexandre; Baumberg, Jeremy J.; Bowman, Richard W.
2016-02-01
Open source hardware has the potential to revolutionise the way we build scientific instruments; with the advent of readily available 3D printers, mechanical designs can now be shared, improved, and replicated faster and more easily than ever before. However, printed parts are typically plastic and often perform poorly compared to traditionally machined mechanisms. We have overcome many of the limitations of 3D printed mechanisms by exploiting the compliance of the plastic to produce a monolithic 3D printed flexure translation stage, capable of sub-micron-scale motion over a range of 8 × 8 × 4 mm. This requires minimal post-print clean-up and can be automated with readily available stepper motors. The resulting plastic composite structure is very stiff and exhibits remarkably low drift, moving less than 20 μm over the course of a week, without temperature stabilisation. This enables us to construct a miniature microscope with excellent mechanical stability, perfect for time-lapse measurements in situ in an incubator or fume hood. The ease of manufacture lends itself to use in containment facilities where disposability is advantageous and to experiments requiring many microscopes in parallel. High performance mechanisms based on printed flexures need not be limited to microscopy, and we anticipate their use in other devices both within the laboratory and beyond.
NASA Astrophysics Data System (ADS)
Chen, Lin; Sun, Limin; Nagarajaiah, Satish
2016-09-01
Lateral dampers have been extensively studied and implemented for supplementing modal damping in cable vibration mitigation. When considering the cable flexural stiffness that is actually present, albeit small, there is another degree of freedom of the cable at the lateral damper, namely the rotation, that can be constrained by a rotational damper to achieve larger additional damping. This is of particular significance for long cables where the near-anchorage lateral damper alone is usually insufficient. The problem of a cable with bending stiffness, attached with both lateral and rotational dampers at an intermediate point, is therefore considered in this study. The characteristic equation of the resulting system is formulated by assembling the dynamic stiffness from the two segments divided by the damper, which is subsequently solved using argument principle method. Dynamics of the controlled system is thus discussed in general through parametric analysis. For the case where the damper location is close to the anchorage, asymptotic solutions for complex frequency and damping ratio are provided; explicit formulas for determining the optimal damper coefficients are also derived. It is found that when the lateral and rotational damper coefficients are properly balanced, the proposed strategy can achieve up to 30 percent damping enhancement compared to the case with only the lateral damper, in practical cable bending stiffness range.
NASA Astrophysics Data System (ADS)
Sahoo, Sushree S.; Singh, Vijay K.; Panda, Subrata K.
2015-02-01
Flexural behaviour of cross ply laminated woven Glass/Epoxy composite plate has been investigated in this article. Flexural responses are examined by a three point bend test and tensile test carried out on INSTRON 5967 and Universal Testing Machine INSTRON 1195 respectively. The finite element model is developed in ANSYS parametric design language code and discretised using an eight nodded structural shell element. Convergence behaviour of the simulation result has been performed and validated by comparing the results with experimental values. The effects of various parameters such as side-to-thickness ratio, modular ratio on flexural behaviour of woven Glass/Epoxy laminated composite plate are discussed in details.
Ashley-Ross, Miriam A; Perlman, Benjamin M; Gibb, Alice C; Long, John H
2014-02-01
Despite having no obvious anatomical modifications to facilitate movement over land, numerous small fishes from divergent teleost lineages make brief, voluntary terrestrial forays to escape poor aquatic conditions or to pursue terrestrial prey. Once stranded, these fishes produce a coordinated and effective "tail-flip" jumping behavior, wherein lateral flexion of the axial body into a C-shape, followed by contralateral flexion of the body axis, propels the fish into a ballistic flight-path that covers a distance of multiple body lengths. We ask: how do anatomical structures that evolved in one habitat generate effective movement in a novel habitat? Within this context, we hypothesized that the mechanical properties of the axial skeleton play a critical role in producing effective overland movement, and that tail-flip jumping species demonstrate enhanced elastic energy storage through increased body flexural stiffness or increased body curvature, relative to non-jumping species. To test this hypothesis, we derived a model to predict elastic recoil work from the morphology of the vertebral (neural and hemal) spines. From ground reaction force (GRF) measurements and high-speed video, we calculated elastic recoil work, flexural stiffness, and apparent material stiffness of the body for Micropterus salmoides (a non-jumper) and Kryptolebias marmoratus (adept tail-flip jumper). The model predicted no difference between the two species in work stored by the vertebral spines, and GRF data showed that they produce the same magnitude of mass-specific elastic recoil work. Surprisingly, non-jumper M. salmoides has a stiffer body than tail-flip jumper K. marmoratus. Many tail-flip jumping species possess enlarged, fused hypural bones that support the caudal peduncle, which suggests that the localized structures, rather than the entire axial skeleton, may explain differences in terrestrial performance. Copyright © 2013 Elsevier GmbH. All rights reserved.
A structural model for the flexural mechanics of nonwoven tissue engineering scaffolds.
Engelmayr, George C; Sacks, Michael S
2006-08-01
The development of methods to predict the strength and stiffness of biomaterials used in tissue engineering is critical for load-bearing applications in which the essential functional requirements are primarily mechanical. We previously quantified changes in the effective stiffness (E) of needled nonwoven polyglycolic acid (PGA) and poly-L-lactic acid (PLLA) scaffolds due to tissue formation and scaffold degradation under three-point bending. Toward predicting these changes, we present a structural model for E of a needled nonwoven scaffold in flexure. The model accounted for the number and orientation of fibers within a representative volume element of the scaffold demarcated by the needling process. The spring-like effective stiffness of the curved fibers was calculated using the sinusoidal fiber shapes. Structural and mechanical properties of PGA and PLLA fibers and PGA, PLLA, and 50:50 PGA/PLLA scaffolds were measured and compared with model predictions. To verify the general predictive capability, the predicted dependence of E on fiber diameter was compared with experimental measurements. Needled nonwoven scaffolds were found to exhibit distinct preferred (PD) and cross-preferred (XD) fiber directions, with an E ratio (PD/XD) of approximately 3:1. The good agreement between the predicted and experimental dependence of E on fiber diameter (R2 = 0.987) suggests that the structural model can be used to design scaffolds with E values more similar to native soft tissues. A comparison with previous results for cell-seeded scaffolds (Engelmayr, G. C., Jr., et al., 2005, Biomaterials, 26(2), pp. 175-187) suggests, for the first time, that the primary mechanical effect of collagen deposition is an increase in the number of fiber-fiber bond points yielding effectively stiffer scaffold fibers. This finding indicated that the effects of tissue deposition on needled nonwoven scaffold mechanics do not follow a rule-of-mixtures behavior. These important results underscore the need for structural approaches in modeling the effects of engineered tissue formation on nonwoven scaffolds, and their potential utility in scaffold design.
Effects of metal- and fiber-reinforced composite root canal posts on flexural properties.
Kim, Su-Hyeon; Oh, Tack-Oon; Kim, Ju-Young; Park, Chun-Woong; Baek, Seung-Ho; Park, Eun-Seok
2016-01-01
The aim of this study was to observe the effects of different test conditions on the flexural properties of root canal post. Metal- and fiber-reinforced composite root canal posts of various diameters were measured to determine flexural properties using a threepoint bending test at different conditions. In this study, the span length/post diameter ratio of root canal posts varied from 3.0 to 10.0. Multiple regression models for maximum load as a dependent variable were statistically significant. The models for flexural properties as dependent variables were statistically significant, but linear regression models could not be fitted to data sets. At a low span length/post diameter ratio, the flexural properties were distorted by occurrence of shear stress in short samples. It was impossible to obtain high span length/post diameter ratio with root canal posts. The addition of parameters or coefficients is necessary to appropriately represent the flexural properties of root canal posts.
Hu, Rui; Liu, Shutian; Li, Quhao
2017-05-20
For the development of a large-aperture space telescope, one of the key techniques is the method for designing the flexures for mounting the primary mirror, as the flexures are the key components. In this paper, a topology-optimization-based method for designing flexures is presented. The structural performances of the mirror system under multiple load conditions, including static gravity and thermal loads, as well as the dynamic vibration, are considered. The mirror surface shape error caused by gravity and the thermal effect is treated as the objective function, and the first-order natural frequency of the mirror structural system is taken as the constraint. The pattern repetition constraint is added, which can ensure symmetrical material distribution. The topology optimization model for flexure design is established. The substructuring method is also used to condense the degrees of freedom (DOF) of all the nodes of the mirror system, except for the nodes that are linked to the mounting flexures, to reduce the computation effort during the optimization iteration process. A potential optimized configuration is achieved by solving the optimization model and post-processing. A detailed shape optimization is subsequently conducted to optimize its dimension parameters. Our optimization method deduces new mounting structures that significantly enhance the optical performance of the mirror system compared to the traditional methods, which only focus on the parameters of existing structures. Design results demonstrate the effectiveness of the proposed optimization method.
Tensile and Flexural Test on Kenaf Hybrid Composites
NASA Astrophysics Data System (ADS)
Salleh, Z.; Yunus, S.; Masdek, N. R. N. M.; Taib, Y. M.; Azhar, I. I. S.; Hyie, K. M.
2018-03-01
The widely use of synthetic materials like carbon and fiberglass in various industries such as automotive and aircraft has lead to human health and environment problems. Therefore, the use of natural fibres such as kenaf has received higher attention as reinforcement. Kenaf or the scientific name is Hibiscus Cannabinus. L is one of the group of Malvecea plant which in the early days, the application of kenaf served only rope and canvas. However, it has more advantages than synthetic materials such as; widely availaible, renewable, lightweight, non-abbrasiveness during processing, high specific strength, free from health hazard and biodegradeable. This study was carried out to investigate the effects of different arrangement of kenaf and fiberglass composites on Young’s Modulus. The material composite was hardened with polyester resin and their properties was characterized. The tensile and the flexural properties is determined using an Instron universal tensile testing machine and carried out by following ASTM D3039 for tensile and ASTM D790 for a flexural test. The experimental program was designed to correlate the flexural and tensile Young’s Modulus of kenaf and fiberglass composite under the same load condition but different arrangement of kenaf and fiberglass on the mold . The resistance to change in shape was described by the behavior and characteristic of the composite materials. The stiffness or the elastic modulus of the composite material was determined at the end of the experiment. The results obtained show that the [±90FG/0/90/90/0/±90FG] kenaf/fiberglass composite arrangement has the highest elastic value.
NASA Astrophysics Data System (ADS)
Nuruzzaman, D. M.; Kusaseh, N. M.; Chowdhury, M. A.; Rahman, N. A. N. A.; Oumer, A. N.; Fatchurrohman, N.; Iqbal, A. K. M. A.; Ismail, N. M.
2018-04-01
In this research study, glass fiber (GF) reinforced polypropylene (PP)-nylon 6 (PA6) polymer blend composites were prepared using injection molding process. Specimens of four different compositions such as 80%PP+20%PA6, 80%PP+18%PA6+2%GF, 80%PP+16%PA6+4%GF and 80%PP+14%PA6+6%GF were prepared. In the injection molding process, suitable process parameters were selected depending on the type of composite specimen in producing defects free dog bone shaped specimens. Flexure and impact tests were carried out according to ASTM standard. The important flexure properties such as flexural modulus, flexural yield strength, flexural strength and flexural strain were investigated. The obtained results revealed that flexural modulus of 80%PP+20%PA6 polymer blend is the lowest and the polymer blend composite shows steadily improved modulus as the glass fiber content is increased. Results also showed that flexural strength of pure polymer blend is the lowest but it improves gradually when the glass fiber content is increased. Impact test results revealed that impact strength of 80%PP+20%PA6 polymer blend is the highest whereas all the composites show reduced impact strength or toughness. It is noticed that 80%PP+14%PA6+6%GF composite exhibits the lowest impact strength.
Arı, Hatem; Kahraman, Fatih; Türker, Yasin; Güler, Serdar; Baş, Hasan Aydın; Erdoğan, Doğan
2017-10-30
Aortic stiffness is an important cardiovascular risk marker, which can be determined using different noninvasive techniques. Aortic propagation velocity (APV) has recently been established as a novel echocardiographic parameter of aortic stiffness. This study aimed to investigate the association between APV and the classical echocardiography-derived aortic stiffness parameters, aortic distensibility (AD) and aortic strain (AS), in a group of otherwise healthy individuals. In total, 97 consecutive healthy subjects were recruited in this observational study. APV was measured using color M-mode echocardiography from the suprasternal window in the descending aorta. AS and AD were calculated using clinical blood pressure and the M-mode echocardiography-derived aortic diameters. Correlation analyses were performed between cardiovascular risk factors related to increased aortic stiffness (age, obesity, and blood pressure) and measured stiffness parameters (APV, AS, and AD). Correlation analyses were also performed among the measured stiffness parameters. Good correlation of age, blood pressure, and BMI with AS and AD was observed. One-on-one correlation of age, blood pressure, and BMI with APV was not observed. No correlation was observed between APV and AS (r=-0.05, p=0.6) or between APV and AD (r=-0.17, p=0.8). Although APV has been proposed as a novel and practical echocardiographic parameter of aortic stiffness, especially in patients with coronary artery disease, correlations between classical stiffness parameters (AS and AD) and APV were absent in healthy individuals at low-intermediate risk. The clinical and research applicability of APV should be further evaluated.
Optimal Shakedown of the Thin-Wall Metal Structures Under Strength and Stiffness Constraints
NASA Astrophysics Data System (ADS)
Alawdin, Piotr; Liepa, Liudas
2017-06-01
Classical optimization problems of metal structures confined mainly with 1st class cross-sections. But in practice it is common to use the cross-sections of higher classes. In this paper, a new mathematical model for described shakedown optimization problem for metal structures, which elements are designed from 1st to 4th class cross-sections, under variable quasi-static loads is presented. The features of limited plastic redistribution of forces in the structure with thin-walled elements there are taken into account. Authors assume the elastic-plastic flexural buckling in one plane without lateral torsional buckling behavior of members. Design formulae for Methods 1 and 2 for members are analyzed. Structures stiffness constrains are also incorporated in order to satisfy the limit serviceability state requirements. With the help of mathematical programming theory and extreme principles the structure optimization algorithm is developed and justified with the numerical experiment for the metal plane frames.
Design, analysis and testing of a new piezoelectric tool actuator for elliptical vibration turning
NASA Astrophysics Data System (ADS)
Lin, Jieqiong; Han, Jinguo; Lu, Mingming; Yu, Baojun; Gu, Yan
2017-08-01
A new piezoelectric tool actuator (PETA) for elliptical vibration turning has been developed based on a hybrid flexure hinge connection. Two double parallel four-bar linkage mechanisms and two right circular flexure hinges were chosen to guide the motion. The two input displacement directional stiffness were modeled according to the principle of virtual work modeling method and the kinematic analysis was conducted theoretically. Finite element analysis was used to carry out static and dynamic analyses. To evaluate the performance of the developed PETA, off-line experimental tests were carried out to investigate the step responses, motion strokes, resolutions, parasitic motions, and natural frequencies of the PETA along the two input directions. The relationship between input displacement and output displacement, as well as the tool tip’s elliptical trajectory in different phase shifts was analyzed. By using the developed PETA mechanism, micro-dimple patterns were generated as the preliminary application to demonstrate the feasibility and efficiency of PETA for elliptical vibration turning.
Hierarchical flexural strength of enamel: transition from brittle to damage-tolerant behaviour
Bechtle, Sabine; Özcoban, Hüseyin; Lilleodden, Erica T.; Huber, Norbert; Schreyer, Andreas; Swain, Michael V.; Schneider, Gerold A.
2012-01-01
Hard, biological materials are generally hierarchically structured from the nano- to the macro-scale in a somewhat self-similar manner consisting of mineral units surrounded by a soft protein shell. Considerable efforts are underway to mimic such materials because of their structurally optimized mechanical functionality of being hard and stiff as well as damage-tolerant. However, it is unclear how different hierarchical levels interact to achieve this performance. In this study, we consider dental enamel as a representative, biological hierarchical structure and determine its flexural strength and elastic modulus at three levels of hierarchy using focused ion beam (FIB) prepared cantilevers of micrometre size. The results are compared and analysed using a theoretical model proposed by Jäger and Fratzl and developed by Gao and co-workers. Both properties decrease with increasing hierarchical dimension along with a switch in mechanical behaviour from linear-elastic to elastic-inelastic. We found Gao's model matched the results very well. PMID:22031729
Development of flax/carbon fibre hybrid composites for enhanced properties.
Dhakal, H N; Zhang, Z Y; Guthrie, R; Macmullen, J; Bennett, N
2013-07-01
Uni-directional (UD) and cross-ply (CP) cellulosic flax fibre epoxy composites were produced by hybridising UD carbon fibre prepreg onto flax system. A compression moulding technique was used to produce both flax and carbon/flax hybridised laminates. The effect of carbon fibre hybridisation on the water absorption behaviour, thermal and mechanical properties of both UD and CP flax specimens were investigated by means of water absorption, tensile, thermogravemetric analysis and flexural testing. The results showed that water absorption behaviour of hybrid samples are markedly improved compared to those without hybridisation. Similarly, the thermal stability, tensile and flexural properties of the hybrid composites are significantly improved in comparison with UD and CP flax composites without hybridisation. The experimental results suggest that cellulosic flax fibre reinforcement contributed to improve the toughness properties by promoting crack propagation whereas the carbon fibre contributed in improving thermal stability, water absorption behaviour and the overall strength and the stiffness of the hybrid composites. Copyright © 2013 Elsevier Ltd. All rights reserved.
Creep of a Silicon Nitride Under Various Specimen/Loading Configurations
NASA Technical Reports Server (NTRS)
Choi, Sung R.; Powers, Lynn M.; Holland, Frederic A.; Gyekenyesi, John P.; Holland, F. A. (Technical Monitor)
2000-01-01
Extensive creep testing of a hot-pressed silicon nitride (NC132) was performed at 1300 C in air using five different specimen/loading configurations, including pure tension, pure compression, four-point uniaxial flexure, ball-on-ring biaxial flexure, and ring-on-ring biaxial flexure. Nominal creep strain and its rate for a given nominal applied stress were greatest in tension, least in compression, and intermediate in uniaxial and biaxial flexure. Except for the case of compressive loading, nominal creep strain generally decreased with time, resulting in less-defined steady-state condition. Of the four different creep formulations - power-law, hyperbolic sine, step, redistribution models - the conventional power-law model still provides the most convenient and reasonable means to estimate simple, quantitative creep parameters of the material. Predictions of creep deformation for the case of multiaxial stress state (biaxial flexure) were made based on pure tension and compression creep data by using the design code CARES/Creep.
NASA Astrophysics Data System (ADS)
Lovely, Peter; Chauvin, Benjamin; Brennan, Patrick; Laroche, Matt
2015-04-01
Understanding paleobathymetry is important to hydrocarbon explorationists, as it impacts depositional environments, reservoir quality, source rock preservation, hydrocarbon migration pathways, and paleo-stress. At long wavelengths (basin scale), bathymetry is controlled predominantly by isostatic compensation of vertical loads, which include sediment, water and spatial and temporal variations in the thickness and temperature of the crust and lithospheric mantle. Roberts, et al. (2003) present a workflow to account for these loads and derive paleobathymetry by 3-D flexural backstripping. However, to our knowledge, commercially packaged software for flexural backstripping is limited to two dimensions, and 3-D software is limited to Airy isostasy, which does not account for the elastic stiffness of the earth's crust and may, as a result, produce local error of 1km or more. We have developed a 3-D backstripping application that incorporates flexural isostasy, and is implemented in a workflow modeled after Roberts, et al. (2003). The application restores the isostatic components of basin geometry and bathymetry, and may account for the effects of sediment loading (isostasy & compaction), and rift-related subsidence (post- and syn-rift effects of homogeneous or depth-dependent pure-shear stretching models. Effects of dynamic topography, if quantifiable, may be prescribed as a bulk shift after backstripping. Implemented as a plug-in to Gocad, the application is accessible to a broad audience of geoscientists. The flexural isostasy implementation accounts for basin geometry and spatially heterogeneous layer thickness by discretizing each layer as a series of cylindrical loads of varying density and thickness at the nodes of a square grid. The isostatic effect of a single cylindrical load is provided by Brotchie & Silvester (1969) and the effect of multiple loads may be summed linearly. An iterative approach for calculating local water depth accounts for variations in eustatic sea level, allows for emergent topography, and overcomes potential pitfalls associated with the analytical solution for a "filled" basin. We review the numerical implementation of flexural backstripping, and discuss implications, as well as limitations, of paleobathymetric maps for source rock preservation and reservoir presence in two diverse passive margin settings: offshore Liberia and the Northwest Shelf of Australia.
NASA Astrophysics Data System (ADS)
Kis, A.; Kasas, S.; Babić, B.; Kulik, A. J.; Benoît, W.; Briggs, G. A.; Schönenberger, C.; Catsicas, S.; Forró, L.
2002-11-01
We have determined the mechanical anisotropy of a single microtubule by simultaneously measuring the Young's and the shear moduli in vitro. This was achieved by elastically deforming the microtubule deposited on a substrate tailored by electron-beam lithography with a tip of an atomic force microscope. The shear modulus is 2orders of magnitude lower than the Young's, giving rise to a length-dependent flexural rigidity of microtubules. The temperature dependence of the microtubule's bending stiffness in the (5-40) °C range shows a strong variation upon cooling coming from the increasing interaction between the protofilaments.
Analysis and Testing of a Tapered End Connection for Laser Welded Steel Sandwich Panels
2009-08-15
bending moments, Mx, My and Mxy, and applied load, q, as follows: dx dy *x dM „, dM , ex • + • dy -e,-o dQ, , dQ + ^ + q = 0 dx...Q,’D{ Qy dy The governing equations are then solved with respect to the orthotropic flexural and shear stiffness’, DM , Dm Dxy, and DQX, DQy. The...the lens. Each 55 lens has its own advantages such as delivering sharp and crisp results with almost no linear or barrel distortion, which renders
The Effect of Stiffness Parameter on Mass Distribution in Heavy-Ion Induced Fission
NASA Astrophysics Data System (ADS)
Soheyli, Saeed; Khalil Khalili, Morteza; Ashrafi, Ghazaaleh
2018-06-01
The stiffness parameter of the composite system has been studied for several heavy-ion induced fission reactions without the contribution of non-compound nucleus fission events. In this research, determination of the stiffness parameter is based on the comparison between the experimental data on the mass widths of fission fragments and those predicted by the statistical model treatments at the saddle and scission points. Analysis of the results shows that for the induced fission reactions of different targets by the same projectile, the stiffness parameter of the composite system decreases with increasing the fissility parameter, as well as with increasing the mass number of the compound nucleus. This parameter also exhibits a similar behavior for the reactions of a given target induced by different projectiles. As expected, nearly same stiffness values are obtained for different reactions leading to the same compound nucleus.
Analysis of Flexural Fatigue Strength of Self Compacting Fibre Reinforced Concrete Beams
NASA Astrophysics Data System (ADS)
Murali, G.; Sudar Celestina, J. P. Arul; Subhashini, N.; Vigneshwari, M.
2017-07-01
This study presents the extensive statistical investigation ofvariations in flexural fatigue life of self-compacting Fibrous Concrete (FC) beams. For this purpose, the experimental data of earlier researchers were examined by two parameter Weibull distribution.Two methods namely Graphical and moment wereused to analyse the variations in experimental data and the results have been presented in the form of probability of survival. The Weibull parameters values obtained from graphical and method of moments are precise. At 0.7 stress level, the fatigue life shows 59861 cyclesfor areliability of 90%.
Nelson, Stacy; English, Shawn; Briggs, Timothy
2016-05-06
Fiber-reinforced composite materials offer light-weight solutions to many structural challenges. In the development of high-performance composite structures, a thorough understanding is required of the composite materials themselves as well as methods for the analysis and failure prediction of the relevant composite structures. However, the mechanical properties required for the complete constitutive definition of a composite material can be difficult to determine through experimentation. Therefore, efficient methods are necessary that can be used to determine which properties are relevant to the analysis of a specific structure and to establish a structure's response to a material parameter that can only be definedmore » through estimation. The objectives of this paper deal with demonstrating the potential value of sensitivity and uncertainty quantification techniques during the failure analysis of loaded composite structures; and the proposed methods are applied to the simulation of the four-point flexural characterization of a carbon fiber composite material. Utilizing a recently implemented, phenomenological orthotropic material model that is capable of predicting progressive composite damage and failure, a sensitivity analysis is completed to establish which material parameters are truly relevant to a simulation's outcome. Then, a parameter study is completed to determine the effect of the relevant material properties' expected variations on the simulated four-point flexural behavior as well as to determine the value of an unknown material property. This process demonstrates the ability to formulate accurate predictions in the absence of a rigorous material characterization effort. Finally, the presented results indicate that a sensitivity analysis and parameter study can be used to streamline the material definition process as the described flexural characterization was used for model validation.« less
Liang, Lihua; Sun, Mingxiao; Shi, Hongyu; Luan, Tiantian
2017-01-01
Fin-angle feedback control is usually used in conventional fin stabilizers, and its actual anti-rolling effect is difficult to reach theoretical design requirements. Primarily, lift of control torque is a theoretical value calculated by static hydrodynamic characteristics of fin. However, hydrodynamic characteristics of fin are dynamic while fin is moving in waves. As a result, there is a large deviation between actual value and theoretical value of lift. Firstly, the reasons of deviation are analyzed theoretically, which could avoid a variety of interference factors and complex theoretical derivations. Secondly, a new device is designed for direct measurement of actual lift, which is composed of fin-shaft combined mechanism and sensors. This new device can make fin-shaft not only be the basic function of rotating fin, but also detect actual lift. Through analysis using stiffness matrix of Euler-Bernoulli beam, displacement of shaft-core end is measured instead of lift which is difficult to measure. Then quantitative relationship between lift and displacement is defined. Three main factors are analyzed with quantitative relationship. What is more, two installation modes of sensors and a removable shaft-end cover are proposed according to hydrodynamic characteristics of fin. Thus the new device contributes to maintenance and measurement. Lastly, the effectiveness and accuracy of device are verified by contrasting calculation and simulation on the basis of actual design parameters. And the new measuring lift method can be proved to be effective through experiments. The new device is achieved from conventional fin stabilizers. Accordingly, the reliability of original equipment is inherited. The alteration of fin stabilizers is minor, which is suitable for engineering application. In addition, the flexural properties of fin-shaft are digitized with analysis of stiffness matrix. This method provides theoretical support for engineering application by carrying out finite element analysis with computers. PMID:28046122
Comparative Analysis of the Flexural Stiffness of Pinniped Vibrissae
Ginter Summarell, Carly C.; Ingole, Sudeep; Fish, Frank E.; Marshall, Christopher D.
2015-01-01
Vibrissae are important components of the mammalian tactile sensory system and are used to detect vibrotactile stimuli in the environment. Pinnipeds have the largest and most highly innervated vibrissae among mammals, and the hair shafts function as a biomechanical filter spanning the environmental stimuli and the neural mechanoreceptors deep in the follicle-sinus complex. Therefore, the material properties of these structures are critical in transferring vibrotactile information to the peripheral nervous system. Vibrissae were tested as cantilever beams and their flexural stiffness (EI) was measured to test the hypotheses that the shape of beaded vibrissae reduces EI and that vibrissae are anisotropic. EI was measured at two locations on each vibrissa, 25% and 50% of the overall length, and at two orientations to the point force. EI differed in orientations that were normal to each other, indicating a functional anisotropy. Since vibrissae taper from base to tip, the second moment of area (I) was lower at 50% than 25% of total length. The anterior orientation exhibited greater EI values at both locations compared to the dorsal orientation for all species. Smooth vibrissae were generally stiffer than beaded vibrissae. The profiles of beaded vibrissae are known to decrease the amplitude of vibrations when protruded into a flow field. The lower EI values of beaded vibrissae, along with the reduced vibrations, may function to enhance the sensitivity of mechanoreceptors to detection of small changes in flow from swimming prey by increasing the signal to noise ratio. This study builds upon previous morphological and hydrodynamic analyses of vibrissae and is the first comparative study of the mechanical properties of pinniped vibrissae. PMID:26132102
Tangorra, James L; Lauder, George V; Hunter, Ian W; Mittal, Rajat; Madden, Peter G A; Bozkurttas, Meliha
2010-12-01
A biorobotic pectoral fin was developed and used to study how the flexural rigidities of fin rays within a highly deformable fish fin affect the fin's propulsive forces. The design of the biorobotic fin was based on a detailed analysis of the pectoral fin of the bluegill sunfish (Lepomis macrochirus). The biorobotic fin was made to execute the kinematics used by the biological fin during steady swimming, and to have structural properties that modeled those of the biological fin. This resulted in an engineered fin that had a similar interaction with the water as the biological fin and that created close approximations of the three-dimensional motions, flows, and forces produced by the sunfish during low speed, steady swimming. Experimental trials were conducted during which biorobotic fins of seven different stiffness configurations were flapped at frequencies from 0.5 to 2.0 Hz in flows with velocities that ranged from 0 to 270 mm s(-1). During these trials, thrust and lift forces were measured, kinematics were recorded in three dimensions, and digital particle image velocimetry was used to evaluate flow hydrodynamics. The results of the trials revealed that slight changes to the fin's mechanical properties or to the operating conditions can have significant impact on the direction, magnitude and time course of the propulsive forces. In general, the magnitude of the 2-D (thrust and lift) propulsive force scaled with fin ray stiffness, and increased as the fin's flapping speed increased or as the velocity of the flow decreased.
Szewciw, Lawrence; Barthelat, Francois
2017-09-01
Teleost fish skin is a multifunctional natural material with high penetration resistance owing to specialized puncture mechanisms of both the individual scale and the intact scaled integument. In this paper, we explore the possible additional role of the skin in fish undulatory locomotion by examining the structural and mechanical properties of the dermal stratum (s.) compactum layer of striped bass (Morone saxatilis) skin. The structure, mechanical response and function of s. compactum was investigated by combining several methods: optical microscopy and histology, tensile tests on descaled skin specimens in different anatomical locations and orientations, puncture tests, and flexural tests on whole fish with disruption of the s. compactum. Local histological features of the s. compactum, such as collagen fiber angle and degree of crimping, were shown to explain corresponding patterns determined for the tensile properties of the skin along the long axis of the fish, including changes in stiffness, strength and locking strain at stiffening. The fish bending tests demonstrated a tendon-like response of the whole fish and a significant contribution of the s. compactum to the flexural stiffness of the fish. Collectively, the findings show that the s. compactum is a strong tissue with a tendon-like nonlinear response, and which provides an appreciable mechanical protection against sharp puncture and lacerations. Our results also support the theory of an exotendon function of the s. compactum in teleost fish skin. These findings may inspire the design of new multifunctional protective and locomotory systems for a variety of engineering applications. Copyright © 2016 Elsevier Ltd. All rights reserved.
Analysis on Flexural Strength of A36 Mild Steel by Design of Experiment (DOE)
NASA Astrophysics Data System (ADS)
Nurulhuda, A.; Hafizzal, Y.; Izzuddin, MZM; Sulawati, MRN; Rafidah, A.; Suhaila, Y.; Fauziah, AR
2017-08-01
Nowadays demand for high quality and reliable components and materials are increasing so flexural tests have become vital test method in both the research and manufacturing process and development to explain in details about the material’s ability to withstand deformation under load. Recently, there are lack research studies on the effect of thickness, welding type and joint design on the flexural condition by DOE approach method. Therefore, this research will come out with the flexural strength of mild steel since it is not well documented. By using Design of Experiment (DOE), a full factorial design with two replications has been used to study the effects of important parameters which are welding type, thickness and joint design. The measurement of output response is identified as flexural strength value. Randomize experiments was conducted based on table generated via Minitab software. A normal probability test was carried out using Anderson Darling Test and show that the P-value is <0.005. Thus, the data is not normal since there is significance different between the actual data with the ideal data. Referring to the ANOVA, only factor joint design is significant since the P-value is less than 0.05. From the main plot and interaction plot, the recommended setting for each of parameters were suggested as high level for welding type, high level for thickness and low level for joint design. The prediction model was developed thru regression in order to measure effect of output response for any changes on parameters setting. In the future, the experiments can be enhanced using Taguchi methods in order to do verification of result.
Effect of plasma welding parameters on the flexural strength of Ti-6Al-4V alloy.
Lyra e Silva, João Paulo; Fernandes Neto, Alfredo Júlio; Raposo, Luís Henrique Araújo; Novais, Veridiana Resende; de Araujo, Cleudmar Amaral; Cavalcante, Luisa de Andrade Lima; Simamoto Júnior, Paulo Cezar
2012-01-01
The aim of this study was to assess the effect of different plasma arc welding parameters on the flexural strength of titanium alloy beams (Ti-6Al-4V). Forty Ti-6Al-4V and 10 NiCr alloy beam specimens (40 mm long and 3.18 mm diameter) were prepared and divided into 5 groups (n=10). The titanium alloy beams for the control group were not sectioned or subjected to welding. Groups PL10, PL12, and PL14 contained titanium beams sectioned and welded at current 3 A for 10, 12 or 14 ms, respectively. Group NCB consisted of NiCr alloy beams welded using conventional torch brazing. After, the beams were subjected to a three-point bending test and the values obtained were analyzed to assess the flexural strength (MPa). Statistical analysis was carried out by one-way ANOVA and Tukey's HSD test at 0.05 confidence level. Significant difference was verified among the evaluated groups (p<0.001), with higher flexural strength for the control group (p<0.05). No significant differences was observed among the plasma welded groups (p>0.05). The NCB group showed the lowest flexural strength, although it was statistically similar to the PL 14 group (p>0.05). The weld depth penetration was not significantly different among the plasma welded groups (p=0.05). Three representative specimens were randomly selected to be evaluated under scanning electron microcopy. The composition of the welded regions was analyzed by energy dispersive X-ray spectroscopy. This study provides an initial set of parameters supporting the use of plasma welding during fabrication of titanium alloy dental frameworks.
NASA Astrophysics Data System (ADS)
Zhang, Jianbin; Sun, Xiantao; Chen, Weihai; Chen, Wenjie; Jiang, Lusha
2014-12-01
In microelectromechanical system (MEMS) optical switch assembly, the collision always exists between the optical fiber and the edges of the U-groove due to the positioning errors between them. It will cause the irreparable damage since the optical fiber and the silicon-made U-groove are usually very fragile. Typical solution is first to detect the positioning errors by the machine vision or high-resolution sensors and then to actively eliminate them with the aid of the motion of precision mechanisms. However, this method will increase the cost and complexity of the system. In this paper, we present a passive compensation method to accommodate the positioning errors. First, we study the insertion process of the optical fiber into the U-groove to analyze all possible positioning errors as well as the conditions of successful insertion. Then, a novel passive flexure-based mechanism based on the remote center of compliance concept is designed to satisfy the required insertion condition. The pseudo-rigid-body-model method is utilized to calculate the stiffness of the mechanism along the different directions, which is verified by finite element analysis (FEA). Finally, a prototype of the passive flexure-based mechanism is fabricated for performance tests. Both FEA and experimental results indicate that the designed mechanism can be used to the MEMS optical switch assembly.
Confinement Effect on Material Properties of RC Beams Under Flexure
NASA Astrophysics Data System (ADS)
Kulkarni, Sumant; Shiyekar, Mukund Ramchandra; Shiyekar, Sandip Mukund
2017-12-01
In structural analysis, especially in indeterminate structures, it becomes essential to know the material and geometrical properties of members. The codal provisions recommend elastic properties of concrete and steel and these are fairly accurate enough. The stress-strain curve for concrete cylinder or a cube specimen is plotted. The slope of this curve is modulus of elasticity of plain concrete. Another method of determining modulus of elasticity of concrete is by flexural test of a beam specimen. The modulus of elasticity most commonly used for concrete is secant modulus. The modulus of elasticity of steel is obtained by performing a tension test of steel bar. While performing analysis by any software for high rise building, cross area of plain concrete is taken into consideration whereas effects of reinforcement bars and concrete confined by stirrups are neglected. Present aim of study is to determine elastic properties of reinforced cement concrete beam. Two important stiffness properties such as AE and EI play important role in analysis of high rise RCC building idealized as plane frame. The experimental program consists of testing of beams (model size 150 × 150 × 700 mm) with percentage of reinforcement varying from 0.54 to 1.63% which commensurate with existing Codal provisions of IS:456-2000 for flexural member. The effect of confinement is considered in this study. The experimental results are verified by using 3D finite element techniques.
Force monitoring transducers with more than 100,000 scale intervals
NASA Astrophysics Data System (ADS)
Stavrov, Vladimir; Shulev, Assen; Chakarov, Dimiter; Stavreva, Galina
2015-05-01
This paper presents the results obtained at characterization of novel, high performing force transducers to be employed into monitoring systems with very high accuracy. Each force transducer comprises of a coherently designed mechanical transducer and a position microsensor with very high accuracy. The range of operation for the mechanical transducer has been optimized to fit the 500μm travel range of the position microsensor. Respectively, the flexures' stiffness corresponds to achieve the maximum displacement at 70N load force. The position microsensor is a MEMS device, comprising of two rigid elements: an anchored and an actuated ones connected via one monolithic micro-flexure. Additionally, the micro-flexure comprises of two strain detecting cantilevers having four sidewall embedded piezoresistors connected in a Wheatstone bridge. The particular sensor provides a voltage signal having sensitivity in the range of 240μV/μm at 1V DC voltage supply. The experimental set-up for measurement of the load curve of the force transducer has demonstrated an overall force resolution of about 0.6mN. As a result, more than 100,000 scale intervals have been experimentally assessed. The present work forms development of a common approach for accurate measurement of various physical values, when they are transduced in a multi-D displacement. Due to the demonstrated high accuracy, the force transducers with piezoresistive MEMS sensors remove most of the constraints in force monitoring with ppm-accuracy.
Zhang, Jianbin; Sun, Xiantao; Chen, Weihai; Chen, Wenjie; Jiang, Lusha
2014-12-01
In microelectromechanical system (MEMS) optical switch assembly, the collision always exists between the optical fiber and the edges of the U-groove due to the positioning errors between them. It will cause the irreparable damage since the optical fiber and the silicon-made U-groove are usually very fragile. Typical solution is first to detect the positioning errors by the machine vision or high-resolution sensors and then to actively eliminate them with the aid of the motion of precision mechanisms. However, this method will increase the cost and complexity of the system. In this paper, we present a passive compensation method to accommodate the positioning errors. First, we study the insertion process of the optical fiber into the U-groove to analyze all possible positioning errors as well as the conditions of successful insertion. Then, a novel passive flexure-based mechanism based on the remote center of compliance concept is designed to satisfy the required insertion condition. The pseudo-rigid-body-model method is utilized to calculate the stiffness of the mechanism along the different directions, which is verified by finite element analysis (FEA). Finally, a prototype of the passive flexure-based mechanism is fabricated for performance tests. Both FEA and experimental results indicate that the designed mechanism can be used to the MEMS optical switch assembly.
Biomechanics and functional morphology of a climbing monocot
Hesse, Linnea; Wagner, Sarah T.; Neinhuis, Christoph
2016-01-01
Plants with a climbing growth habit possess unique biomechanical properties arising from adaptations to changing loading conditions connected with close attachment to mechanical supports. In monocot climbers, mechanical adaptation is restricted by the absence of a bifacial vascular cambium. Flagellaria indica was used to investigate the mechanical properties and adaptations of a monocot climber that, uniquely, attaches to the surrounding vegetation via leaf tendrils. Biomechanical methods such as three-point bending and torsion tests were used together with anatomical studies on tissue development, modification and distribution. In general, the torsional modulus was lower than the bending modulus; hence, torsional stiffness was less than flexural stiffness. Basal parts of mature stems showed the greatest stiffness while that of more apical stem segments levelled off. Mechanical properties were modulated via tissue maturation processes mainly affecting the peripheral region of the stem. Peripheral vascular bundles showed a reduction in the amount of conducting tissue while the proportion and density of the bundle sheath increased. Furthermore, adjacent bundle sheaths merged resulting in a dense ring of fibrous tissue. Although F. indica lacks secondary cambial growth, the climbing habit is facilitated by a complex interaction of tissue maturation and attachment. PMID:26819259
Electrostatic adhesion for added functionality of composite structures
NASA Astrophysics Data System (ADS)
Heath, Callum J. C.; Bond, Ian P.; Potter, Kevin D.
2016-02-01
Electrostatic adhesion can be used as a means of reversible attachment. The incorporation of electrostatic adhesion into fibre reinforced polymer (FRP) composite structures could provide significant value added functionality. Imparting large potential differences (˜2 kV) across electrodes generates an attractive force, thus providing a means of attachment. This could be used as a reversible latching mechanism or as a means of controllable internal connectivity. Varying the connectivity for discrete elements of a substructure of a given design allows for control of internal load paths and moment of area of the cross section. This could facilitate variable stiffness (both in bending and torsion). Using a combination of existing fabrication techniques, functional electrodes have been integrated within a FRP. Copper polyimide thin film laminate material has been both co-cured with carbon fibre reinforced epoxy and bonded to PVC closed cell foam core material to provide a range of structural configurations with integrated electrodes. The ability of such integrated devices to confer variations in global bending stiffness of basic beam structures is investigated. Through the application of 4 kV across integrated electrostatic adhesive devices, a 112% increase in flexural stiffness has been demonstrated for a composite sandwich structure.
Mechanical properties and material characterization of polysialate structural composites
NASA Astrophysics Data System (ADS)
Foden, Andrew James
One of the major concerns in using Fiber Reinforced Composites in applications that are subjected to fire is their resistance to high temperature. Some of the fabrics used in FRC, such as carbon, are fire resistant. However, almost all the resins used cannot withstand temperatures higher than 200°C. This dissertation deals with the development and use of a potassium aluminosilicate (GEOPOLYMER) resin that is inorganic and can sustain more than 1000°C. The results presented include the mechanical properties of the unreinforced polysialate matrix in tension, flexure, and compression as well as the strain capacities and surface energy. The mechanical properties of the matrix reinforced with several different fabrics were obtained in flexure, tension, compression and shear. The strength and stiffness of the composite was evaluated for each loading condition. Tests were conducted on unexposed samples as well as samples exposed to temperatures from 200 to 1000°C. Fatigue properties were determined using flexural loading. A study of the effect of several processing variables on the properties of the composite was undertaken to determine the optimum procedure for manufacturing composite plates. The processing variables studied were the curing temperature and pressure, and the post cure drying time required to remove any residual water. The optimum manufacturing conditions were determined using the void content, density, fiber volume fraction, and flexural strength. Analytical models are presented based on both micro and macro mechanical analysis of the composite. Classic laminate theory is used to evaluate the state of the composite as it is being loaded to determine the failure mechanisms. Several failure criteria theories are considered. The analysis is then used to explain the mechanical behavior of the composite that was observed during the experimental study.
Reliability Analysis of Uniaxially Ground Brittle Materials
NASA Technical Reports Server (NTRS)
Salem, Jonathan A.; Nemeth, Noel N.; Powers, Lynn M.; Choi, Sung R.
1995-01-01
The fast fracture strength distribution of uniaxially ground, alpha silicon carbide was investigated as a function of grinding angle relative to the principal stress direction in flexure. Both as-ground and ground/annealed surfaces were investigated. The resulting flexural strength distributions were used to verify reliability models and predict the strength distribution of larger plate specimens tested in biaxial flexure. Complete fractography was done on the specimens. Failures occurred from agglomerates, machining cracks, or hybrid flaws that consisted of a machining crack located at a processing agglomerate. Annealing eliminated failures due to machining damage. Reliability analyses were performed using two and three parameter Weibull and Batdorf methodologies. The Weibull size effect was demonstrated for machining flaws. Mixed mode reliability models reasonably predicted the strength distributions of uniaxial flexure and biaxial plate specimens.
A Novel Model to Simulate Flexural Complements in Compliant Sensor Systems
Tang, Hongyan; Zhang, Dan; Guo, Sheng; Qu, Haibo
2018-01-01
The main challenge in analyzing compliant sensor systems is how to calculate the large deformation of flexural complements. Our study proposes a new model that is called the spline pseudo-rigid-body model (spline PRBM). It combines dynamic spline and the pseudo-rigid-body model (PRBM) to simulate the flexural complements. The axial deformations of flexural complements are modeled by using dynamic spline. This makes it possible to consider the nonlinear compliance of the system using four control points. Three rigid rods connected by two revolute (R) pins with two torsion springs replace the three lines connecting the four control points. The kinematic behavior of the system is described using Lagrange equations. Both the optimization and the numerical fitting methods are used for resolving the characteristic parameters of the new model. An example is given of a compliant mechanism to modify the accuracy of the model. The spline PRBM is important in expanding the applications of the PRBM to the design and simulation of flexural force sensors. PMID:29596377
Murdock, Kyle; Martin, Caitlin; Sun, Wei
2018-01-01
Flexure is an important mode of deformation for native and bioprosthetic heart valves. However, mechanical characterization of bioprosthetic leaflet materials has been done primarily through planar tensile testing. In this study, an integrated experimental and computational cantilever beam bending test was performed to characterize the flexural properties of glutaraldehyde-treated bovine and porcine pericardium of different thicknesses. A strain-invariant based structural constitutive model was used to model the pericardial mechanical behavior quantified through the bending tests of this study and the planar biaxial tests previously performed. The model parameters were optimized through an inverse finite element (FE) procedure in order to describe both sets of experimental data. The optimized material properties were implemented in FE simulations of transcatheter aortic valve (TAV) deformation. It was observed that porcine pericardium TAV leaflets experienced significantly more flexure than bovine when subjected to opening pressurization, and that the flexure may be overestimated using a constitutive model derived from purely planar tensile experimental data. Thus, modeling of a combination of flexural and biaxial tensile testing data may be necessary to more accurately describe the mechanical properties of pericardium, and to computationally investigate bioprosthetic leaflet function and design. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Ergin, Mehmet; Aktar, Mustafa
2018-04-01
High quality broadband data, together with the application of the double difference relocation technique, has been used to study the characteristics of the lower crustal seismicity in the Adana Basin, in southwestern Turkey. Deep events are clearly seen to be restricted only to the Adana Basin and never extend outside its boundaries. Furthermore, the seismogenic zone is observed to align roughly with the main axis of the basin and plunges steadily in the SSW-direction, following the basement trend of the Adana Basin. Similarities between geometries of the basin evolution and the deep seismic production suggest that both processes are closely related. A flexure process is proposed related to the subsidence of the Adana Basin. The seismogenic zone, originally at a shallow depth, is assumed to have been displaced vertically into the lower crust, by flexure. The temperature evolution of the crust during the flexure has been studied in detail using finite difference modeling, with amplitude and duration parameters taken from earlier studies. It has been concluded that the physical conditions for brittle fracturing remained unchanged for an extended period of time after the flexure. The brittle layers originally at shallow depths, preserved their original thermal properties after the subsidence and will continue to produce earthquakes at considerable depths. Numerical tests using inferred parameters imply a total vertical shift of 7-8 km for the seismogenic zone. Discussions for additional processes, which may further contribute to the cooling of the crust, are also included.
Human arm stiffness and equilibrium-point trajectory during multi-joint movement.
Gomi, H; Kawato, M
1997-03-01
By using a newly designed high-performance manipulandum and a new estimation algorithm, we measured human multi-joint arm stiffness parameters during multi-joint point-to-point movements on a horizontal plane. This manipulandum allows us to apply a sufficient perturbation to subject's arm within a brief period during movement. Arm stiffness parameters were reliably estimated using a new algorithm, in which all unknown structural parameters could be estimated independent of arm posture (i.e., constant values under any arm posture). Arm stiffness during transverse movement was considerably greater than that during corresponding posture, but not during a longitudinal movement. Although the ratios of elbow, shoulder, and double-joint stiffness were varied in time, the orientation of stiffness ellipses during the movement did not change much. Equilibrium-point trajectories that were predicted from measured stiffness parameters and actual trajectories were slightly sinusoidally curved in Cartesian space and their velocity profiles were quite different from the velocity profiles of actual hand trajectories. This result contradicts the hypothesis that the brain does not take the dynamics into account in movement control depending on the neuromuscular servo mechanism; rather, it implies that the brain needs to acquire some internal models of controlled objects.
Flexural creep behaviour of jute polypropylene composites
NASA Astrophysics Data System (ADS)
Chandekar, Harichandra; Chaudhari, Vikas
2016-09-01
Present study is about the flexural creep behaviour of jute fabric reinforced polypropylene (Jute-PP) composites. The PP sheet and alkali treated jute fabric is stacked alternately and hot pressed in compression molding machine to get Jute-PP composite laminate. The flexural creep study is carried out on dynamic mechanical analyzer. The creep behaviour of the composite is modeled using four-parameter Burgers model. Short-term accelerated creep testing is conducted which is later used to predict long term creep behaviour. The feasibility of the construction of a master curve using the time-temperature superposition (TTS) principle to predict long term creep behavior of unreinforced PP and Jute-PP composite is investigated.
Vriz, Olga; Aboyans, Victor; Minisini, Rosalba; Magne, Julien; Bertin, Nicole; Pirisi, Mario; Bossone, Eduardo
2017-07-01
Arterial stiffness can predict cardiovascular events, and the aim of this study was to produce age- and sex-specific reference values for echo-tracking carotid stiffness in healthy subjects. A total of 900 subjects (500 males, mean age 45.8±19 years) were enrolled. Common carotid artery stiffness and compliance, using a high-definition echo-tracking ultrasound system, were evaluated. To compare stiffness parameters across the different age groups, individual scores were transformed into T-scores, indicating how many standard deviation (s.d.) units an individual's score was above or below the mean that was observed in the group including same-sex individuals aged 36 to 44 years. Carotid stiffness was similar among genders, except compliance, which was lower in women (P<0.0001). These characteristics were also maintained when the studied population was divided into seven age groups. Stiffness parameters increased significantly with age, but the opposite occurred for compliance. The T-score was found to increase significantly across all age groups, with a steeper increase in stiffness around the age of 60 years in women. For each T-score s.d., the corresponding carotid absolute values for arterial stiffness and compliance were obtained. In a multivariate model, carotid stiffness parameters were constantly and independently associated with age, mean arterial pressure, pulse pressure, heart rate and body mass index. Our study provides a normogram of carotid arterial stiffness and compliance indices obtained with the echo-tracking method in a large population of healthy subjects stratified by gender and age that can be used in clinical practice.
MECHANICAL PROPERTIES OF TOTALLY PERMEABLE TITANIUM COMPOSITE PYLON FOR DIRECT SKELETAL ATTACHMENT
Pitkin, M.; Pilling, J.; Raykhtsaum, G.
2012-01-01
Composite pylons containing a solid titanium core with drilled holes surrounded by a porous sintered titanium shell have been fabricated and tested in bending along with the raw cores and pylons composed of the porous titanium alone. The new pylons were designed with the concept of enhanced ingrowth of bone and skin cells and are intended for direct skeletal attachment of limb prostheses considering requirements for long-lasting anchorage to the residuum bone and a need for a safe skin-implant seal. Load-displacement thresholds were determined after which the integrity of the porous component may be compromised. The composite pylons have a flexural strength and stiffness substantially greater than that of pylons composed of the porous titanium alone. The drilled holes in the solid insert have been shown to have virtually no effect on the flexural strength of the pylon, while meeting a requirement for total permeability of the device for unrestricted cell ingrowth. The predicted strength of the pylons and associated failure modes are in close agreement with those measured. PMID:22287509
The structure and mechanics of Moso bamboo material
Dixon, P. G.; Gibson, L. J.
2014-01-01
Although bamboo has been used structurally for millennia, there is currently increasing interest in the development of renewable and sustainable structural bamboo products (SBPs). These SBPs are analogous to wood products such as plywood, oriented strand board and glue-laminated wood. In this study, the properties of natural Moso bamboo (Phyllostachys pubescens) are investigated to further enable the processing and design of SBPs. The radial and longitudinal density gradients in bamboo give rise to variations in the mechanical properties. Here, we measure the flexural properties of Moso bamboo in the axial direction, along with the compressive strengths in the axial and transverse directions. Based on the microstructural variations (observed with scanning electron microscopy) and extrapolated solid cell wall properties of bamboo, we develop models, which describe the experimental results well. Compared to common North American construction woods loaded along the axial direction, Moso bamboo is approximately as stiff and substantially stronger, in both flexure and compression but denser. This work contributes to critical knowledge surrounding the microstructure and mechanical properties of bamboo, which are vital to the engineering and design of sustainable SBPs. PMID:25056211
NASA Astrophysics Data System (ADS)
Herrmann, Kelsey M.
Research to date indicates that traditional composite material failure analysis methods are not appropriate for thin laminates in flexure. Thin composite structures subjected to large bending deformations often attain significantly higher strain-to-failure than previously anticipated tensile and compression coupon test data and linear material model assumption predict. At NASA Langley Research Center, a new bend test method is being developed for High Strain Composite (HSC) structures. This method provides an adequate approximation of a pure moment, large deformation bend test for thin-ply, high strain composites to analyze the large strain flexure response of the laminates. The objective of this research was to further develop this new test method to measure the true bending stiffness and strain-to-failure of high strain composite materials. Of primary importance is the ability to characterize composite laminates that are of interest for current NASA deployable structures in both materials and layups. Two separate testing campaigns were performed for the development of the testing procedure. Initially six laminates were bend tested in three different fiber orientations. These laminates were some combination of unidirectional intermediate modulus (IM) carbon, high tenacity (HT) carbon plain weave, and astroquartz plain weave composite materials. The second test campaign was performed as a more detailed look into the simplest composite laminates at thicknesses that better represented deployable boom structures. The second campaign tested three basic, thinner laminates, again in three different fiber orientations. All testing was monotonic loading to failure. The thickness of the laminates tested ranged from 0.166mm (campaign 2) to 0.45mm (campaign 1). The measured strains at failure for the unidirectional material were approximately 2.1% and 1.4% at the compression and tension sides, respectively, failing as fiber tensile fracture. Both of these values differ from what would be expected from considering much thicker coupons tested under pure compression and tension, that show a strain-to-failure of 1.0-1.1% and 1.6-1.7%, respectively. The significant differences in strain values obtained at the outer surfaces of the coupon is thought to be related to the shift in neutral axis that the specimen experiences during the large deformation bending test as a result of fiber material nonlinearities at higher strains. The vertical test nature of the CBT when compared to other test methods proves to be helpful for visually capturing with Digital Image Correlation the distinct behavior of the flexure on both the compressive and tensile sides. It was found that the thinner the laminate tested, the more confirmation of a nonlinear response of this classification of composites. The moment versus curvature curves were predominantly nonlinear resulting in a near linear bending stiffness versus curvature response. At these large strains, carbon fibers are highly nonlinear resulting in the laminate flexure modulus increasing by up to 5x. The theoretical bending stiffness values calculated using Classical Lamination Theory analysis are within small differences with respect to the experimentally measured values: errors of approximately 5-10% for both D11 and D22. The error between the finite element model computed strain response and the experimental values was on average around 22%, with 35% of the laminates and orientation having errors less than 7%. Comparison between CLT, FEA, and experimentation show that the Column Bend Test appears to be a promising candidate for characterization of large deformation bending behavior of thin-ply high strain composite laminates.
NASA Astrophysics Data System (ADS)
Ene, Alexandru
The objective of this dissertation is to assess whether or not two particular biocomposite materials, made from hemp fabric and cellulose acetate or polyhydroxybutyrate matrices, are capable of being used for structural and/or construction purposes within in the construction and building industry. The objective of this dissertation was addressed by conducting research to meet the following three goals: (1) to measure the basic mechanical properties of hemp/cellulose acetate and hemp/PHB biocomposites and evaluate if they suitable for use in construction applications, (2) to determine how quickly moisture diffuses into the biocomposite materials and how the moisture affects the mechanical behavior, and (3) to determine how well simple models can predict behavior of structural scale laminates in tension and flexure using biocomposite ply behavior. Compression molding was used to manufacturing the biocomposites from hemp fabric and the themoplastic matrices: cellulose acetate and polyhydroxybutyrate. Four methods for determining the fiber volume fraction were evaluated, and the dissolution method, using different solvents for each matrix type, was used to determine the fiber volume fraction for each composite plate manufactured. Both types of biocomposite were tested in tension, compression, shear, and flexure and the measured properties were compared to wood and engineered wood products to assess whether the biocomposite properties are suitable for use in the construction industry. The biocomposites were conditioned in a humid environment to determine the rate of moisture diffusion into the materials. Then saturated specimens and specimens that were saturated and then dried were tested in tension to evaluate how moisture absorption affects the mechanical behavior of the biocomposites. Finally, simple models of laminate behavior based on laminate plate theory were evaluated to determine if ply level behavior could be used to predict structural scale laminate behavior. While the biocomposite strengths in flexure, compression, and shear were comparable to the strengths of wood and wood-based products parallel to grain, the biocomposite strengths exceeded the strengths perpendicular to the wood grain, as would be expected with fabric reinforcement. The biocomposite moduli of elasticity were between 35% and 75% of the wood moduli parallel to grain. While structural shape of the biocomposites could be manipulated to achieve a comparable structural stiffness to replace wood and short fiber FRPs, the biocomposites have comparable stiffness to the engineered wood-products. Thus, in terms of mechanical properties, the biocomposites can be used in place of engineered-wood products. Yet, the higher densities of the biocomposites as compared to wood and engineered-wood products may limit their implementation in construction. The diffusion coefficients for both biocomposites were comparable to wood and higher than the coefficients for synthetic composites as expected due to the hydrophilicity of the natural fibers. Significantly greater moisture absorption of the hemp/cellulose acetate composite as compared to the hemp/PHB composite was attributed to the cellulose acetate itself being hydrophilic whereas PHB is hydrophobic. The rate of diffusion for both materials was found to increase with increasing temperature. Moisture absorption negatively affected the biocomposites as shown through lower initial stiffnesses and higher strains at failure of saturated specimens. The hemp/cellulose acetate composites were much more affected by moisture absorption than the hemp/PHB composites likely because the moisture plasticized the cellulose acetate and also weakened the interfacial fiber-matrix bond. Moisture was assumed to cause permanent damage because the stress-strain behavior did not return to the unconditioned behavior upon drying of the saturated specimens. The degradation of mechanical properties upon introduction to humid environments limits the potential applications of these biocomposites. For these biocomposites to be used widely within the construction industry, they must therefore be protected from moisture for example through sealants and/or fiber treatments. Classical laminate plate theory was shown to be effective in predicting the initial linear behavior of all of the laminates in tension and flexure, but did not capture stiffness degradation or the full nonlinear stress-strain response of the biocomposites because the model was for linear elastic materials. Use of this model would be appropriate for design of deflection-limited applications within certain stress ranges. The modified nonlinear laminate plate theory predicted the initial stress-strain response well, but at higher strains overestimated the strength and stiffness. The overestimation was attributed to the constitutive model assuming uncoupled stress-strain behavior for each strain component and, additionally in flexure, to the use of tensile behavior as the constitutive behavior in compression. While the simple models provided an adequate prediction of laminate behavior at low strains, to predict behavior at higher strains, it is recommended instead to evaluate the use of finite element analysis to predict response using experimental stress-strain as models for orthotropic materials and non-linear behavior are well-established. (Abstract shortened by UMI.)
Mechanical characterization and structural assessment of biocomposites for construction
NASA Astrophysics Data System (ADS)
Christian, Sarah Jane
The objective of this dissertation is to assess whether or not two particular biocomposite materials, made from hemp fabric and cellulose acetate or polyhydroxybutyrate matrices, are capable of being used for structural and/or construction purposes within in the construction and building industry. The objective of this dissertation was addressed by conducting research to meet the following three goals: (1) to measure the basic mechanical properties of hemp/cellulose acetate and hemp/PHB biocomposites and evaluate if they suitable for use in construction applications, (2) to determine how quickly moisture diffuses into the biocomposite materials and how the moisture affects the mechanical behavior, and (3) to determine how well simple models can predict behavior of structural scale laminates in tension and flexure using biocomposite ply behavior. Compression molding was used to manufacturing the biocomposites from hemp fabric and the themoplastic matrices: cellulose acetate and polyhydroxybutyrate. Four methods for determining the fiber volume fraction were evaluated, and the dissolution method, using different solvents for each matrix type, was used to determine the fiber volume fraction for each composite plate manufactured. Both types of biocomposite were tested in tension, compression, shear, and flexure and the measured properties were compared to wood and engineered wood products to assess whether the biocomposite properties are suitable for use in the construction industry. The biocomposites were conditioned in a humid environment to determine the rate of moisture diffusion into the materials. Then saturated specimens and specimens that were saturated and then dried were tested in tension to evaluate how moisture absorption affects the mechanical behavior of the biocomposites. Finally, simple models of laminate behavior based on laminate plate theory were evaluated to determine if ply level behavior could be used to predict structural scale laminate behavior. While the biocomposite strengths in flexure, compression, and shear were comparable to the strengths of wood and wood-based products parallel to grain, the biocomposite strengths exceeded the strengths perpendicular to the wood grain, as would be expected with fabric reinforcement. The biocomposite moduli of elasticity were between 35% and 75% of the wood moduli parallel to grain. While structural shape of the biocomposites could be manipulated to achieve a comparable structural stiffness to replace wood and short fiber FRPs, the biocomposites have comparable stiffness to the engineered wood-products. Thus, in terms of mechanical properties, the biocomposites can be used in place of engineered-wood products. Yet, the higher densities of the biocomposites as compared to wood and engineered-wood products may limit their implementation in construction. The diffusion coefficients for both biocomposites were comparable to wood and higher than the coefficients for synthetic composites as expected due to the hydrophilicity of the natural fibers. Significantly greater moisture absorption of the hemp/cellulose acetate composite as compared to the hemp/PHB composite was attributed to the cellulose acetate itself being hydrophilic whereas PHB is hydrophobic. The rate of diffusion for both materials was found to increase with increasing temperature. Moisture absorption negatively affected the biocomposites as shown through lower initial stiffnesses and higher strains at failure of saturated specimens. The hemp/cellulose acetate composites were much more affected by moisture absorption than the hemp/PHB composites likely because the moisture plasticized the cellulose acetate and also weakened the interfacial fiber-matrix bond. Moisture was assumed to cause permanent damage because the stress-strain behavior did not return to the unconditioned behavior upon drying of the saturated specimens. The degradation of mechanical properties upon introduction to humid environments limits the potential applications of these biocomposites. For these biocomposites to be used widely within the construction industry, they must therefore be protected from moisture for example through sealants and/or fiber treatments. Classical laminate plate theory was shown to be effective in predicting the initial linear behavior of all of the laminates in tension and flexure, but did not capture stiffness degradation or the full nonlinear stress-strain response of the biocomposites because the model was for linear elastic materials. Use of this model would be appropriate for design of deflection-limited applications within certain stress ranges. The modified nonlinear laminate plate theory predicted the initial stress-strain response well, but at higher strains overestimated the strength and stiffness. The overestimation was attributed to the constitutive model assuming uncoupled stress-strain behavior for each strain component and, additionally in flexure, to the use of tensile behavior as the constitutive behavior in compression. While the simple models provided an adequate prediction of laminate behavior at low strains, to predict behavior at higher strains, it is recommended instead to evaluate the use of finite element analysis to predict response using experimental stress-strain as models for orthotropic materials and non-linear behavior are well-established. (Abstract shortened by UMI.)
Endpoint Accuracy in Manual Control of a Steerable Needle.
van de Berg, Nick J; Dankelman, Jenny; van den Dobbelsteen, John J
2017-02-01
To study the ability of a human operator to manually correct for errors in the needle insertion path without partial withdrawal of the needle by means of an active, tip-articulated steerable needle. The needle is composed of a 1.32-mm outer-diameter cannula, with a flexure joint near the tip, and a retractable stylet. The bending stiffness of the needle resembles that of a 20-gauge hypodermic needle. The needle functionality was evaluated in manual insertions by steering to predefined targets and a lateral displacement of 20 mm from the straight insertion line. Steering tasks were conducted in 5 directions and 2 tissue simulants under image guidance from a camera. The repeatability in instrument actuations was assessed during 100 mm deep automated insertions with a linear motor. In addition to tip position, tip angles were tracked during the insertions. The targeting error (mean absolute error ± standard deviation) during manual steering to 5 different targets in stiff tissue was 0.5 mm ± 1.1. This variability in manual tip placement (1.1 mm) was less than the variability among automated insertions (1.4 mm) in the same tissue type. An increased tissue stiffness resulted in an increased lateral tip displacement. The tip angle was directly controlled by the user interface, and remained unaffected by the tissue stiffness. This study demonstrates the ability to manually steer needles to predefined target locations under image guidance. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Hedayatrasa, Saeid; Kersemans, Mathias; Abhary, Kazem; Uddin, Mohammad; Van Paepegem, Wim
2018-01-01
Phononic crystal plates (PhPs) have promising application in manipulation of guided waves for design of low-loss acoustic devices and built-in acoustic metamaterial lenses in plate structures. The prominent feature of phononic crystals is the existence of frequency bandgaps over which the waves are stopped, or are resonated and guided within appropriate defects. Therefore, maximized bandgaps of PhPs are desirable to enhance their phononic controllability. Porous PhPs produced through perforation of a uniform background plate, in which the porous interfaces act as strong reflectors of wave energy, are relatively easy to produce. However, the research in optimization of porous PhPs and experimental validation of achieved topologies has been very limited and particularly focused on bandgaps of flexural (asymmetric) wave modes. In this paper, porous PhPs are optimized through an efficient multiobjective genetic algorithm for widest complete bandgap of mixed fundamental guided wave modes (symmetric and asymmetric) and maximized stiffness. The Pareto front of optimization is analyzed and variation of bandgap efficiency with respect to stiffness is presented for various optimized topologies. Selected optimized topologies from the stiff and compliant regimes of Pareto front are manufactured by water-jetting an aluminum plate and their promising bandgap efficiency is experimentally observed. An optimized Pareto topology is also chosen and manufactured by laser cutting a Plexiglas (PMMA) plate, and its performance in self-collimation and focusing of guided waves is verified as compared to calculated dispersion properties.
He, Guo; Liu, Ping; Tan, Qingbiao; Jiang, Guofeng
2013-12-01
The entangled titanium materials with various porosities have been investigated in terms of the flexural and compressive mechanical properties and the deformation and failure modes. The effect of the sintering parameters on the mechanical properties and the porosity reduction has been comprehensively studied. The results indicate that both the flexural and compressive mechanical properties increase significantly as the porosity decreases. In the porosity range investigated the flexural elastic modulus is in the range of 0.05-6.33GPa, the flexural strength is in the range of 9.8-324.9MPa, the compressive elastic modulus is in the range of 0.03-2.25GPa, and the compressive plateau stress is in the range of 2.3-147.8MPa. The mechanical properties of the entangled titanium materials can be significantly improved by sintering, which increase remarkably as the sintering temperature and/or the sintering time increases. But on other hand, the sintering process can induce the porosity reduction due to the oxidation on the titanium wire surface. © 2013 Elsevier Ltd. All rights reserved.
Effect of drought stress on bending stiffness in petioles of Caladium bicolor (Araceae).
Caliaro, Marco; Schmich, Florian; Speck, Thomas; Speck, Olga
2013-11-01
Cell turgor plays an important role in the mechanical stability of herbaceous plants. This study on petioles of Caladium bicolor 'Candyland' analyzes the correlation between flexural rigidity and cell turgor. The results offer new insights into the underlying form-structure-function relationship and the dependency of mechanical properties from water availability. Bending modulus E of petioles is calculated from two-point bending tests, taking into account the tapering mode. The corresponding turgor of parenchyma cells during wilting is investigated by pressure probe tests. Wilting petioles show highly significant lower values of E than petioles with sufficient water supply. These differences are also found when comparing well-watered petioles to drought-stressed petioles having parenchyma turgor values in the same range. These results indicate an additional mechanical system sensitive to drought stress. On the basis of analyses of the contribution of different petiolar tissues toward the axial second moment of area and by using experimentally determined and literature values of E for the different tissues, we were able to (1) recalculate E of the intact petiole and to compare it with experimental data and (2) quantitatively estimate the importance of the different tissues for flexural rigidity and E of the petiole. Our results show that the decrease in flexural rigidity of petioles of Caladium bicolor 'Candyland' during wilting results from (1) a water-loss-induced decrease in mechanical efficiency of collenchyma fibers and (2) turgor loss of parenchyma cells.
Vibration isolation by exploring bio-inspired structural nonlinearity.
Wu, Zhijing; Jing, Xingjian; Bian, Jing; Li, Fengming; Allen, Robert
2015-10-08
Inspired by the limb structures of animals/insects in motion vibration control, a bio-inspired limb-like structure (LLS) is systematically studied for understanding and exploring its advantageous nonlinear function in passive vibration isolation. The bio-inspired system consists of asymmetric articulations (of different rod lengths) with inside vertical and horizontal springs (as animal muscle) of different linear stiffness. Mathematical modeling and analysis of the proposed LLS reveal that, (a) the system has very beneficial nonlinear stiffness which can provide flexible quasi-zero, zero and/or negative stiffness, and these nonlinear stiffness properties are adjustable or designable with structure parameters; (b) the asymmetric rod-length ratio and spring-stiffness ratio present very beneficial factors for tuning system equivalent stiffness; (c) the system loading capacity is also adjustable with the structure parameters which presents another flexible benefit in application. Experiments and comparisons with existing quasi-zero-stiffness isolators validate the advantageous features above, and some discussions are also given about how to select structural parameters for practical applications. The results would provide an innovative bio-inspired solution to passive vibration control in various engineering practice.
In situ rheology of the oceanic lithosphere along the Hawaiian ridge
NASA Astrophysics Data System (ADS)
Pleus, A.; Ito, G.; Wessel, P.; Frazer, L. N.
2017-12-01
Much of our quantitative understanding of lithospheric rheology is based on rock deformation experiments carried out in the laboratory. The accuracy of the relationships between stress and lithosphere deformation, however, are subject to large extrapolations, given that laboratory strain rates (10-7 s-1) are much greater than geologic rates (10-15 to 10-12 s-1). In situ deformation experiments provide independent constraints and are therefore needed to improve our understanding of natural rheology. Zhong and Watts [2013] presented such a study around the main Hawaiian Islands and concluded that the lithosphere flexure requires a much weaker rheology than predicted by laboratory experiments. We build upon this study by investigating flexure around the older volcanoes of the Hawaiian ridge. The ridge is composed of a diversity of volcano sizes that loaded seafloor of nearly constant age (85+/-8 Ma); this fortunate situation allows for an analysis of flexural responses to large variations in applied loads at nearly constant age-dependent lithosphere thermal structure. Our dataset includes new marine gravity and multi-beam bathymetry data collected onboard the Schmidt Ocean Institute's R/V Falkor. These data, along with forward models of lithospheric flexure, are used to obtain a joint posterior probability density function for model parameters that control the lithosphere's flexural response to a given load. These parameters include the frictional coefficient constraining brittle failure in the shallow lithosphere, the activation energy for the low-temperature plasticity regime, and the geothermal gradient of the Hawaiian lithosphere. The resulting in situ rheological parameters may be used to verify or update those derived in the lab. Attaining accurate lithospheric rheological properties is important to our knowledge, not only of the evolution of the Hawaiian lithosphere, but also of other solid-earth geophysical problems, such as oceanic earthquakes, subduction dynamics, and coastal topographic response to sea level rise.
The relationship between arterial wall stiffness and left ventricular dysfunction.
Hu, Y; Li, L; Shen, L; Gao, H
2013-05-01
The purpose of this study was to explore the relationship between left ventricular (LV) dysfunction and arterial wall stiffening. A total of 218 patients over the age of 45 diagnosed with hypertension in Jinan City and hospitalised between 2010 and 2011 were included in this study. LV function was evaluated using echocardiography (ECHO). Blood pressure was monitored with an automated tonometric device, and the parameters of arterial wall stiffness were measured. In addition, the metabolic parameters of blood samples, such as glucose and lipids, were also determined using the Cobas E601 analyser. Stiffness parameter beta positively correlated with LV diastolic function (E/Em ratio) (r = 0.255, p < 0.001). LV end-diastolic diameter not only related to the E/Em ratio (r = 0.196, p = 0.009) but also with beta (r = 0.220, p = 0.002). The stiffness parameter beta was an early indicator of E/Em ratio as determined by multiple regression analysis (R (2) = 0.381, p < 0.01). Age, blood pressure and fasting blood glucose contributed to stiffness parameter beta (p < 0.05), as well as the E/Em ratio (p < 0.01). Our findings suggested that LV dysfunction may have a direct relationship to arterial stiffening, independently of having similar risk factors. In addition, arterial stiffness can be an independent predictor of LV diastolic function, suggesting that the severity of arterial stiffness directly correlates with the severity of LV dysfunction.
McGarvey, K A; Lee, J M; Boughner, D R
1984-03-01
We have examined the tensile viscoelastic properties of fresh and glycerol-preserved human dura mater, and correlated the results with structural information from the scanning electron microscope. The interwoven laminar structure of dura produces rather high flexural stiffness, while the crossed-fibrillar laminae produce planar mechanical isotropy. Glycerol storage shifts the stress-strain curve to lower strain, reduces stress relaxation and creep, and lowers the ultimate tensile strength and strain at fracture. These changes may be due to glyceraldehyde crosslinking, or to increased interfibrillar friction. The latter hypothesis suggests that glycerol storage may reduce the fatigue lifetime of the tissue.
Grande, Nicola M; Plotino, Gianluca; Ioppolo, Pietro; Bedini, Rossella; Pameijer, Cornelis H; Somma, Francesco
2009-05-01
To evaluate whether custom modification resulting in an anatomically shaped post and whether the span/diameter ratio (L/D) would affect the mechanical properties of fiber-reinforced composite posts. Preformed glass-fiber posts (Group 1) and modified glass-fiber posts (Group 2) and glass-fiber rods (Groups 3 and 4) (n=20) were loaded to failure in a three-point bending test to determine the maximum load (N), flexural strength (MPa) and flexural modulus (GPa). The span distance tested for Group 3 was 10.0mm, while for Group 4 was 22.0mm. Data were subjected to different statistical analysis with significance levels of P<0.05. The maximum load recorded for Groups 1 and 2 was 72.5+/-5.9N and 73.4+/-6.4N respectively, while for Groups 3 and 4 was 215.3+/-7N and 156.6+/-3.6N respectively. The flexural strength for Groups 1 and 2 was 914.6+/-53.1MPa and 1069.2+/-115.6MPa, while for Groups 3 and 4 was 685.4+/-22.2MPa and 899.6+/-46.1MPa. The flexural modulus recorded for Groups 1 and 2 was 32.6+/-3.2GPa and 33.4+/-2.2GPa respectively, while for Groups 3 and 4 was 13.7+/-0.3GPa and 34.4+/-0.3GPa respectively. The flexural properties of an anatomically custom modified fiber post were not affected by the modification procedure and the span-diameter ratio is an important parameter for the interpretation of flexural strength and flexural modulus values.
Lin, Chenghe; Jiao, Benzheng; Liu, Shanshan; Guan, Feng; Chung, Nak-Eun; Han, Seung-Ho; Lee, U-Young
2014-03-01
It has been known that mandible ramus flexure is an important morphologic trait for sex determination. However, it will be unavailable when mandible is incomplete or fragmented. Therefore, the anthropometric analysis on incomplete or fragmented mandible becomes more important. The aim of this study is to investigate the sex-discriminant potential of mandible ramus flexure on the Korean three-dimensional (3D) mandible models with anthropometric analysis. The sample consists of 240 three dimensional mandibular models obtained from Korean population (M:F; 120:120, mean age 46.2 y), collected by The Catholic Institute for Applied Anatomy, The Catholic University of Korea. Anthropometric information about 11 metric was taken with Mimics, anthropometry libraries toolkit. These parameters were subjected to different discriminant function analyses using SPSS 17.0. Univariate analyses showed that the resubstitution accuracies for sex determination range from 50.4 to 77.1%. Mandibular flexure upper border (MFUB), maximum ramus vertical height (MRVH), and upper ramus vertical height (URVH) expressed the greatest dimorphism, 72.1 to 77.1%. Bivariate analyses indicated that the combination of MFUB and MRVH hold even higher resubstitution accuracy of 81.7%. Furthermore, the direct and stepwise discriminant analyses with the variables on the upper ramus above flexure could predict sex in 83.3 and 85.0%, respectively. When all variables of mandibular ramus flexure were input in stepwise discriminant analysis, the resubstitution accuracy arrived as high as 88.8%. Therefore, we concluded that the upper ramus above flexure hold the larger potentials than the mandibular ramus flexure itself to predict sexes, and that the equations in bivariate and multivariate analysis from our study will be helpful for sex determination on Korean population in forensic science and law. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Barbieri, C.; Mancin, N.
2003-04-01
The Tertiary evolution of the Venetian area (NE Italy) led to the superposition of three overlapping foreland systems, different in both age and polarity, as a consequence of the main orogenic phases of the Dinarides, to the North-East, the Southern Alps, to the North, and the Apennines, to the South-West, respectively. Aim of this work is to quantify the flexural effect produced by the Southalpine main orogenic phases (Serravallian-Early Pliocene) in the Venetian foredeep, and particularly to evaluate the importance of constrained initial water depth for evaluating correctly the contribution to flexure of the surface loads. To this end, a 2-D flexural modelling has been applied along a N-S trending industrial seismic line (courtesy of ENI-AGIP) extended from the Northern Alps to the Adriatic sea. Once interpreted and depth migrated, the geometries of the sedimentary bodies have been studied and the base of the foredeep wedge, Serravallian-Tortonian in age, related to the Southern Alps load, has been recognized. Water depth variations during Miocene time have been constrained on three wells located along this section. According to bathymetric reconstructions, based on the quantitative study of foraminiferal assemblages, an overall neritic environment (0--200m), developed during Langhian time, was followed by a fast deepening to bathyal conditions (200--600m) to the North, toward the Southern Alps, during Serravallian-Tortonian time, whereas neritic conditions still persisted to the South. According to these constraints, a best fit model was obtained for an Effective Elastic Thickness value of about 20 Km and a belt topography equal to the present day one. The extremely good fit of the model to realty highlights that, in the studied region, flexure related to the Southern Alps is fully due to surface loads (topographic load and initial water depth), and no subloads are requested to improve the fit, unlike a previous proposed model. Such a difference can be due to both the better constraining of the bathymetric parameter and the improvement of geophysical and geological data. A test was also performed to evaluate the actual influence of the bathymetric parameter on flexural response of the crust by modelling a condition with maximum, minimum and zero initial water depth respectively. Results show that this parameter can contribute up to 50% to the total flexure in the studied region.
Stiffness and Damping in Postural Control Increase with Age
Cenciarini, Massimo; Loughlin, Patrick J.; Sparto, Patrick J.; Redfern, Mark S.
2011-01-01
Upright balance is believed to be maintained through active and passive mechanisms, both of which have been shown to be impacted by aging. A compensatory balance response often observed in older adults is increased co-contraction, which is generally assumed to enhance stability by increasing joint stiffness. We investigated the effect of aging on standing balance by fitting body sway data to a previously-developed postural control model that includes active and passive stiffness and damping parameters. Ten young (24 ± 3 y) and seven older (75 ± 5 y) adults were exposed during eyes-closed stance to perturbations consisting of lateral pseudorandom floor tilts. A least-squares fit of the measured body sway data to the postural control model found significantly larger active stiffness and damping model parameters in the older adults. These differences remained significant even after normalizing to account for different body sizes between the young and older adult groups. An age effect was also found for the normalized passive stiffness, but not for the normalized passive damping parameter. This concurrent increase in active stiffness and damping was shown to be more stabilizing than an increase in stiffness alone, as assessed by oscillations in the postural control model impulse response. PMID:19770083
Reproducibility of structural strength and stiffness for graphite-epoxy aircraft spoilers
NASA Technical Reports Server (NTRS)
Howell, W. E.; Reese, C. D.
1978-01-01
Structural strength reproducibility of graphite epoxy composite spoilers for the Boeing 737 aircraft was evaluated by statically loading fifteen spoilers to failure at conditions simulating aerodynamic loads. Spoiler strength and stiffness data were statistically modeled using a two parameter Weibull distribution function. Shape parameter values calculated for the composite spoiler strength and stiffness were within the range of corresponding shape parameter values calculated for material property data of composite laminates. This agreement showed that reproducibility of full scale component structural properties was within the reproducibility range of data from material property tests.
Signatures of Lithospheric Flexure and Elevated Heat Flow in Stereo Topography at Coronae on Venus
NASA Astrophysics Data System (ADS)
O'Rourke, Joseph G.; Smrekar, Suzanne E.
2018-02-01
Signatures of lithospheric flexure were previously identified at a dozen or more large coronae on Venus. Thin plate models fit to topographic profiles return elastic parameters, allowing derivation of mechanical thickness and surface heat flows given an assumed yield strength envelope. However, the low resolution of altimetry data from the NASA Magellan mission has hindered studying the vast majority of coronae, particularly those less than a few hundred kilometers in diameter. Here we search for flexural signatures around 99 coronae over ˜20% of the surface in Magellan altimetry data and stereo-derived topography that was recently assembled from synthetic aperture radar images. We derive elastic thicknesses of ˜2 to 30 km (mostly ˜5 to 15 km) with Cartesian and axisymmetric models at 19 coronae. We discuss the implications of low values that were also noted in earlier gravity studies. Most mechanical thicknesses are estimated as <19 km, corresponding to thermal gradients >24 K km-1. Implied surface heat flows >95 mW m-2—twice the global average in many thermal evolution models—imply that coronae are major contributors to the total heat budget or Venus is cooling faster than expected. Binomial statistics show that "Type 2" coronae with incomplete fracture annuli are significantly less likely to host flexural signatures than "Type 1" coronae with largely complete annuli. Stress calculations predict extensional faulting where nearly all profiles intersect concentric fractures. We failed to identify systematic variations in flexural parameters based on type, geologic setting, or morphologic class. Obtaining quality, high-resolution topography from a planetwide survey is vital to verifying our conclusions.
Silicon Nitride Creep Under Various Specimen-Loading Configurations
NASA Technical Reports Server (NTRS)
Choi, Sung R.; Holland, Frederic A.
2000-01-01
Extensive creep testing of a hot-pressed silicon nitride (NC 132) was performed at 1300 C in air using five different specimen-loading configurations: (1) pure tension, (2) pure compression, (3) four-point uniaxial flexure, (4) ball-on-ring biaxial flexure, and (5) ring-on-ring biaxial flexure. This paper reports experimental results as well as test techniques developed in this work. Nominal creep strain and its rate for a given nominal applied stress were greatest in tension, least in compression, and intermediate in uniaxial and biaxial flexure. Except for the case of compression loading, nominal creep strain generally decreased with time, resulting in a less-defined steady-state condition. Of the four creep formulations-power-law, hyperbolic sine, step, and redistribution--the conventional power-law formulation still provides the most convenient and reasonable estimation of the creep parameters of the NC 132 material. The data base to be obtained will be used to validate the NASA Glenn-developed design code CARES/Creep (ceramics analysis and reliability evaluation of structures and creep).
Xu, Mengchen; Lerner, Amy L; Funkenbusch, Paul D; Richhariya, Ashutosh; Yoon, Geunyoung
2018-02-01
The optical performance of the human cornea under intraocular pressure (IOP) is the result of complex material properties and their interactions. The measurement of the numerous material parameters that define this material behavior may be key in the refinement of patient-specific models. The goal of this study was to investigate the relative contribution of these parameters to the biomechanical and optical responses of human cornea predicted by a widely accepted anisotropic hyperelastic finite element model, with regional variations in the alignment of fibers. Design of experiments methods were used to quantify the relative importance of material properties including matrix stiffness, fiber stiffness, fiber nonlinearity and fiber dispersion under physiological IOP. Our sensitivity results showed that corneal apical displacement was influenced nearly evenly by matrix stiffness, fiber stiffness and nonlinearity. However, the variations in corneal optical aberrations (refractive power and spherical aberration) were primarily dependent on the value of the matrix stiffness. The optical aberrations predicted by variations in this material parameter were sufficiently large to predict clinically important changes in retinal image quality. Therefore, well-characterized individual variations in matrix stiffness could be critical in cornea modeling in order to reliably predict optical behavior under different IOPs or after corneal surgery.
Oatis, Carol A; Wolff, Edward F; Lockard, Margery A; Michener, Lori A; Robbins, Steven J
2013-03-01
Stiffness is a common complaint in individuals with knee osteoarthritis and is a component of the osteoarthritis diagnosis. Yet the relationship between stiffness and function is poorly understood and methods to quantify stiffness are limited. Using a cross-sectional observational design with 66 subjects with knee osteoarthritis, stiffness and damping coefficients were calculated from a relaxed knee oscillation procedure. Gait parameters were measured using an electronic walkway. Self-reported pain, stiffness, and function were measured with the Western Ontario and McMaster Osteoarthritis Index. Correlation and Alexander's normalized-t approximation analyses were used to assess associations among the variables. Subset analysis was performed on subjects with and without tibiofemoral joint crepitus. Slight to moderate correlations existed between stiffness and damping coefficients and most gait parameters ((| r |=0.30-0.56; P<.05) and between Western Ontario and McMaster Osteoarthritis Index scores and all gait parameters (| r |=0.35-0.62; P<.05). The damping coefficient was only slightly associated with patient-rated Western Ontario and McMaster Osteoarthritis Index stiffness subscale scores. Subset analysis revealed significant correlations that differed between those with and without crepitus. These findings suggest that laboratory measured stiffness and damping coefficients, Western Ontario and McMaster Osteoarthritis Index scores and gait-related measurements assess different aspects related to movement in individuals with knee osteoarthritis. Stiffness and damping coefficients may offer the ability to explain gait changes in the knee that are independent of a person's perceptions particularly in the early stages of the disease. Copyright © 2013 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fifield, Leonard S.; Simmons, Kevin L.; Laddha, Sachin
2010-05-17
Plant-based bio-fiber has the potential to achieve weight and cost savings over glass fiber in automotive polymer composites if moisture stability and fiber-resin compatibility issues can be solved. This paper describes the compression molding of 50vol% 2 inch random nonwoven mat kenaf fiber vinyl ester composites with and without chemical resin additives intended to improve moisture stability and resin compatibility. The 2wt% addition of n-undecanoyl chloride or 10-undecenoyl chloride to the styrene-based resin prior to molding of the kenaf composites was observed to decrease the 24hr, 25oC moisture uptake of the molded panels by more than 50%. The tensile stiffnessmore » and flexural stiffness of the soaked panels containing these additives were seen to increase by more than 30% and 70%, respectively, relative to panels made with no additives. While ‘dry’ panel (50% relative humidity at 25oC) strengths did not significantly change in the presence of the additives, tensile strength was observed to increase by more than 40% and flexural strength more than doubled for the soaked panels.« less
Development and Evaluation of Stitched Sandwich Panels
NASA Technical Reports Server (NTRS)
Stanley, Larry E.; Adams, Daniel O.; Reeder, James R. (Technical Monitor)
2001-01-01
This study explored the feasibility and potential benefits provided by the addition of through-the-thickness reinforcement to sandwich structures. Through-the-thickness stitching is proposed to increase the interlaminar strength and damage tolerance of composite sandwich structures. A low-cost, out-of-autoclave processing method was developed to produce composite sandwich panels with carbon fiber face sheets, a closed-cell foam core, and through-the-thickness Kevlar stitching. The sandwich panels were stitched in a dry preform state, vacuum bagged, and infiltrated using Vacuum Assisted Resin Transfer Molding (VARTM) processing. For comparison purposes, unstitched sandwich panels were produced using the same materials and manufacturing methodology. Test panels were produced initially at the University of Utah and later at NASA Langley Research Center. Four types of mechanical tests were performed: flexural testing, flatwise tensile testing, core shear testing, and edgewise compression testing. Drop-weight impact testing followed by specimen sectioning was performed to characterize the damage resistance of stitched sandwich panels. Compression after impact (CAI) testing was performed to evaluate the damage tolerance of the sandwich panels. Results show significant increases in the flexural stiffness and strength, out-of-plane tensile strength, core shear strength, edgewise compression strength, and compression-after-impact strength of stitched sandwich structures.
Converting non-metallic printed circuit boards waste into a value added product.
Muniyandi, Shantha Kumari; Sohaili, Johan; Hassan, Azman; Mohamad, Siti Suhaila
2013-01-01
The aim of this study was to investigate the feasibility of using nonmetallic printed circuit board (PCB) waste as filler in recycled HDPE (rHDPE) in production of rHDPE/PCB composites. Maleic anhydride modified linear low-density polyethylene (MAPE) was used as compatibilizer. In particular, the effects of nonmetallic PCB and MAPE on mechanical properties of the composites were assessed through tensile, flexural and impact testing. Scanning electron microscope (SEM) was used to study the dispersion of nonmetallic PCB and MAPE in the matrix. Nonmetallic PCB was blended with rHDPE from 0-30 wt% and prepared by counter-rotating twin screw extruder followed by molding into test samples via hot press for analysis. A good balance between stiffness, strength and toughness was achieved for the system containing 30 wt% PCB. Thus, this system was chosen in order to investigate the effect of the compatibilizer on the mechanical properties of the composites. The results indicate that MAPE as a compatiblizer can effectively promote the interfacial adhesion between nonmetallic PCB and rHDPE. The addition of 6 phr MAPE increased the flexural strength, tensile strength and impact strength by 71%, 98% and 44% respectively compared to the uncompatibilized composites.
Iwamoto, Shinichiro; Yamamoto, Shigehiro; Lee, Seung-Hwan; Ito, Hirokazu; Endo, Takashi
2014-01-01
Lignocellulose nanofibers were prepared by the wet disk milling of wood flour. First, an ethylene-butene copolymer was pre-compounded with wood flour or lignocellulose nanofibers to prepare master batches. This process involved evaporating the water of the lignocellulose nanofiber suspension during compounding with ethylene-butene copolymer by heating at 105 °C. These master batches were compounded again with polypropylene to obtain the final composites. Since ethylene-butene copolymer is an elastomer, its addition increased the impact strength of polypropylene but decreased the stiffness. In contrast, the wood flour- and lignocellulose nanofiber-reinforced composites showed significantly higher flexural moduli and slightly higher flexural yield stresses than did the ethylene-butene/polypropylene blends. Further, the wood flour composites exhibited brittle fractures during tensile tests and had lower impact strengths than those of the ethylene-butene/polypropylene blends. On the other hand, the addition of the lignocellulose nanofibers did not decrease the impact strength of the ethylene-butene/polypropylene blends. Finally, the addition of wood flour and the lignocellulose nanofibers increased the crystallization temperature and crystallization rate of polypropylene. The increases were more remarkable in the case of the lignocellulose nanofibers than for wood flour. PMID:28788222
Converting non-metallic printed circuit boards waste into a value added product
2013-01-01
The aim of this study was to investigate the feasibility of using nonmetallic printed circuit board (PCB) waste as filler in recycled HDPE (rHDPE) in production of rHDPE/PCB composites. Maleic anhydride modified linear low-density polyethylene (MAPE) was used as compatibilizer. In particular, the effects of nonmetallic PCB and MAPE on mechanical properties of the composites were assessed through tensile, flexural and impact testing. Scanning electron microscope (SEM) was used to study the dispersion of nonmetallic PCB and MAPE in the matrix. Nonmetallic PCB was blended with rHDPE from 0–30 wt% and prepared by counter-rotating twin screw extruder followed by molding into test samples via hot press for analysis. A good balance between stiffness, strength and toughness was achieved for the system containing 30 wt% PCB. Thus, this system was chosen in order to investigate the effect of the compatibilizer on the mechanical properties of the composites. The results indicate that MAPE as a compatiblizer can effectively promote the interfacial adhesion between nonmetallic PCB and rHDPE. The addition of 6 phr MAPE increased the flexural strength, tensile strength and impact strength by 71%, 98% and 44% respectively compared to the uncompatibilized composites. PMID:24764542
Finite Element Development of Honeycomb Panel Configurations with Improved Transmission Loss
NASA Technical Reports Server (NTRS)
Grosveld, Ferdinand W.; Palumbo, Daniel L.; Klos, Jacob; Castle, William D.
2006-01-01
The higher stiffness-to-mass ratio of a honeycomb panel compared to a homogeneous panel results in a lower acoustic critical frequency. Above the critical frequency the panel flexural wave speed is acoustically fast and the structure becomes a more efficient radiator with associated lower sound transmission loss. Finite element models of honeycomb sandwich structures are presented featuring areas where the core is removed from the radiating face sheet disrupting the supersonic flexural and shear wave speeds that exist in the baseline honeycomb panel. These modified honeycomb panel structures exhibit improved transmission loss for a pre-defined diffuse field sound excitation. The models were validated by the sound transmission loss of honeycomb panels measured in the Structural Acoustic Loads and Transmission (SALT) facility at the NASA Langley Research Center. A honeycomb core panel configuration is presented exhibiting a transmission loss improvement of 3-11 dB compared to a honeycomb baseline panel over a frequency range from 170 Hz to 1000 Hz. The improved transmission loss panel configuration had a 5.1% increase in mass over the baseline honeycomb panel, and approximately twice the deflection when excited by a static force.
NASA Astrophysics Data System (ADS)
Yan, Peng; Zhang, Yangming
2018-06-01
High performance scanning of nano-manipulators is widely deployed in various precision engineering applications such as SPM (scanning probe microscope), where trajectory tracking of sophisticated reference signals is an challenging control problem. The situation is further complicated when rate dependent hysteresis of the piezoelectric actuators and the stress-stiffening induced nonlinear stiffness of the flexure mechanism are considered. In this paper, a novel control framework is proposed to achieve high precision tracking of a piezoelectric nano-manipulator subjected to hysteresis and stiffness nonlinearities. An adaptive parameterized rate-dependent Prandtl-Ishlinskii model is constructed and the corresponding adaptive inverse model based online compensation is derived. Meanwhile a robust adaptive control architecture is further introduced to improve the tracking accuracy and robustness of the compensated system, where the parametric uncertainties of the nonlinear dynamics can be well eliminated by on-line estimations. Comparative experimental studies of the proposed control algorithm are conducted on a PZT actuated nano-manipulating stage, where hysteresis modeling accuracy and excellent tracking performance are demonstrated in real-time implementations, with significant improvement over existing results.
Defining the Role of Solid Stress and Matrix Stiffness in Cancer Cell Proliferation and Metastasis
Kalli, Maria; Stylianopoulos, Triantafyllos
2018-01-01
Solid tumors are characterized by an abnormal stroma that contributes to the development of biomechanical abnormalities in the tumor microenvironment. In particular, these abnormalities include an increase in matrix stiffness and an accumulation of solid stress in the tumor interior. So far, it is not clearly defined whether matrix stiffness and solid stress are strongly related to each other or they have distinct roles in tumor progression. Moreover, while the effects of stiffness on tumor progression are extensively studied compared to the contribution of solid stress, it is important to ascertain the biological outcomes of both abnormalities in tumorigenesis and metastasis. In this review, we discuss how each of these parameters is evolved during tumor growth and how these parameters are influenced by each other. We further review the effects of matrix stiffness and solid stress on the proliferative and metastatic potential of cancer and stromal cells and summarize the in vitro experimental setups that have been designed to study the individual contribution of these parameters. PMID:29594037
Ultima Replicated Optics Research
NASA Technical Reports Server (NTRS)
Hadaway, James; Engelhaupt, Darell
1997-01-01
Designs are reviewed incorporating processes suitable for replication of precision spherical segments of very large (greater than 20 meter diameter) telescopes combining ultra-lightweight and high precision. These designs must be amenable to assembly and alignment after deployment . The methods considered lie outside the present scope of fabrication, deployment and alignment considered to date. Design guidelines for reducing the weight and low frequency resonance in low G environment were given by The Serius Group, Dr. Glenn Zeiders, and are considered baseline for this activity. The goal of a rigid design of 10 Kg/sq M is being persued for the Next Generation Space Telescope (NGST) and is not likely adequate for advanced efforts. Flexures have been considered for maintaining the figure of many lightweight structures by control loop processes. This adds to the complexity and weight to the extent that it becomes difficult to recover the benefits. Two fabrication guidelines lead to a stiffer and concurrently lighter structure. First the use of thin vertical wall triangular structural reinforcements to increase the resistance to bending is preferred over hexagonal or square similar sections. Secondly, the incorporation of a similar back sheet on a cellular structure markedly improves the geometric stiffness. Neither improves the short range stiffness. Also often overlooked is that selected material properties must include high microyield and low hysteresis in addition to high elastic modulus to weight (stiffness). The fabrication steps can easily exceed the strain requirement.
Mechanical properties of glass fiber-reinforced endodontic posts.
Cheleux, Nicolas; Sharrock, Patrick J
2009-10-01
Five types of posts from three different manufacturers (RTD, France, Carbotech, France and Ivoclar-Vivadent, Liechenstein) were subjected to three-point bending tests in order to obtain fatigue results, flexural strength and modulus. Transverse and longitudinal polished sections were examined by scanning electron microscopy and evaluated by computer-assisted image analysis. Physical parameters, including volume % of fibers, their dispersion index and coordination number, were calculated and correlated with mechanical properties. The weaker posts showed more fiber dispersion, higher resin contents, larger numbers of visible defects and reduced fatigue resistance. The flexural strength was inversely correlated with fiber diameter and the flexural modulus was weakly related to coordination number, volume % of fibers and dispersion index. The interfacial adhesion between the silica fibers and the resin matrix was observed to be of paramount importance.
Analysis of dynamic properties for a composite robotic arm at intermediate strain rate
NASA Astrophysics Data System (ADS)
Lin, Jin-Chein
The dynamic mechanical properties of any structure are governed by the storage moduli representing the stiffness and loss moduli representing the internal damping capacity. The dynamic mechanical behavior of a graphite epoxy composite laminate in flexural vibration has been investigated. This study presents the results of a theoretical and experimental effort to determine the dynamic properties of multilaminate composites. The effects of fiber orientation and vibration frequency for both unidirectional tape and Kevlar fabric were studied both analytically and experimentally. Measurement of storage and loss moduli were presented for laminated double cantilever beams of fiber reinforced composite with frequency range from 8 to 1230 Hz (up to 5th mode).
Study on the causes and methods of influencing concrete deflection
NASA Astrophysics Data System (ADS)
Zhou, Ying; Zhou, Xiang; Tang, Jinyu
2017-09-01
Under the long-term effect of static load on reinforced concrete beam, the stiffness decreases and the deformation increases with time. Therefore, the calculation of deflection is more complicated. According to the domestic and foreign research results by experiment the flexural deflection of reinforced concrete, creep, age, the thickness of the protective layer, the relative slip, the combination of steel yielding factors of reinforced concrete deflection are summarized, analyzed the advantages and disadvantages of the traditional direct measurement of deflection, that by increasing the beam height, increasing the moment of inertia, ncrease prestressed reinforcement ratio, arching, reduce the load, and other measures to reduce the deflection of prestressed construction, improve the reliability of structure.
Analysis of a piezoelectric bimorph plate with a central-attached mass as an energy harvester.
Jiang, Shunong; Hu, Yuantai
2007-07-01
This article analyzes the performance of a piezoelectric energy harvester in the flexural mode for scavenging ambient vibration energy. The energy harvester consists of a piezoelectric bimorph plate with a central-attached mass. The linear piezoelectricity theory is applied to evaluate the performance dependence upon the physical and geometrical parameters of the model bimorph plate. The analytical solution for the flexural motion of the piezoelectric bimorph plate energy harvester shows that the output power density increases initially, reaches a maximum, then decreases monotonically with the increasing load impedance, which is normalized by a parameter that is a simple combination of the physical and geometrical parameters of the scavenging structure, the bimorph plate, and the frequency of the ambient vibration, underscoring the importance for the load circuit to have the impedance desirable by the scavenging structure. The numerical results illustrate the considerably enhanced performances by adjusting the physical and geometrical parameters of the scavenging structure.
Fellinger, Michael R.; Hector, Louis G.; Trinkle, Dallas R.
2016-10-28
Here, we present an efficient methodology for computing solute-induced changes in lattice parameters and elastic stiffness coefficients Cij of single crystals using density functional theory. We also introduce a solute strain misfit tensor that quantifies how solutes change lattice parameters due to the stress they induce in the host crystal. Solutes modify the elastic stiffness coefficients through volumetric changes and by altering chemical bonds. We compute each of these contributions to the elastic stiffness coefficients separately, and verify that their sum agrees with changes in the elastic stiffness coefficients computed directly using fully optimized supercells containing solutes. Computing the twomore » elastic stiffness contributions separately is more computationally efficient and provides more information on solute effects than the direct calculations. We compute the solute dependence of polycrystalline averaged shear and Young's moduli from the solute dependence of the single-crystal Cij. We then apply this methodology to substitutional Al, B, Cu, Mn, Si solutes and octahedral interstitial C and N solutes in bcc Fe. Comparison with experimental data indicates that our approach accurately predicts solute-induced changes in the lattice parameter and elastic coefficients. The computed data can be used to quantify solute-induced changes in mechanical properties such as strength and ductility, and can be incorporated into mesoscale models to improve their predictive capabilities.« less
Sünbül, Murat; Çinçin, Altuğ; Bozbay, Mehmet; Mammadov, Ceyhun; Ataş, Halil; Özşenel, Ekmel Burak; Sarı, İbrahim; Başaran, Yelda
2016-06-01
Arterial stiffness parameters including pulse wave velocity (PWV) and augmentation index (AIx) are associated with increased risk of cardiovascular disease. A close relationship has been demonstrated between vitamin D deficiency and cardiovascular disease. The aim of the present study was to investigate effects of vitamin D deficiency and supplementation on arterial stiffness parameters in patients with normal cardiac functions. Study population consisted of 45 patients with vitamin D deficiency and normal cardiac functions. Median age (interquartile range) was 45.0 (12.00) years, and 33 patients were female. Patients were treated with oral administration of vitamin D3. Arterial stiffness parameters were evaluated using Mobil-O-Graph arteriograph system, which detected signals from the brachial artery before and after treatment. Vitamin D levels significantly increased after treatment (9.0 [6.00] nmol/L vs 29.0 [11.50] nmol/L, p<0.001). No significant difference was observed among conventional echocardiographic parameters before or after treatment. Post-treatment PVW and AIx were significantly lower than baseline measurements (6.8 [1.55] m/s vs 6.4 [1.30] m/s, p<0.001 and 23.0 [22.00]% vs 31.0 [14.50]%, p<0.001, respectively). Baseline vitamin D levels significantly correlated with PWV (r=-0.352, p=0.018). Post-treatment vitamin D levels also significantly correlated with post-treatment PWV (r=-0.442, p=0.002) and AIx (r=-0.419, p=0.004). Multivariate linear regression analysis revealed no independent predictor of baseline log-transformed PWV. Vitamin D supplementation has beneficial effects on arterial stiffness. Arterial stiffness parameters may aid in the assessment of cardiovascular risk in patients with vitamin D deficiency.
Optimization of self-acting step thrust bearings for load capacity and stiffness.
NASA Technical Reports Server (NTRS)
Hamrock, B. J.
1972-01-01
Linearized analysis of a finite-width rectangular step thrust bearing. Dimensionless load capacity and stiffness are expressed in terms of a Fourier cosine series. The dimensionless load capacity and stiffness were found to be a function of the dimensionless bearing number, the pad length-to-width ratio, the film thickness ratio, the step location parameter, and the feed groove parameter. The equations obtained in the analysis were verified. The assumptions imposed were substantiated by comparing the results with an existing exact solution for the infinite width bearing. A digital computer program was developed which determines optimal bearing configuration for maximum load capacity or stiffness. Simple design curves are presented. Results are shown for both compressible and incompressible lubrication. Through a parameter transformation the results are directly usable in designing optimal step sector thrust bearings.
Effect of gas release in hot molding on flexural strength of composite friction brake
NASA Astrophysics Data System (ADS)
Rusdja, Andy Permana; Surojo, Eko; Muhayat, Nurul; Raharjo, Wijang Wisnu
2018-02-01
Composite friction brake is a vital part of braking system which serves to reduce the speed of vehicle. To fulfill the requirement of brake performance, composite friction brake must have friction and mechanical characteristic as required. The characteristics of composite friction brake are affected by brake material formulation and manufacturing parameter. In the beginning of hot molding, intermittent hot pressing was carried out to release the gases that consist of ammonia gas and water vapor. In composite friction brake, phenolic resin containing hexamethylenetetramine (HMTA) is often used as a binder. During hot molding, the reaction of phenolic resin and HMTA forms ammonia gas. Hot molding also generates water vapor because raw materials absorb moisture from environment when they are placed in storage. The gas release in hot molding is supposed affecting mechanical properties because it avoid entrapped gas in composite, so that this research investigated effect of gas release on flexural strength. Manufacturing of composite specimen was carried out as follow: mixing of raw materials, cold molding, and hot molding. In this research, duration of intermittent hot pressing and number of gas release were varied. The flexural strength of specimen was measured using three point bending test. The results showed that flexural strength specimens that were manufactured without gas release, using 4 times gas release with intermittent hot pressing for 5 and 10 seconds were not remarkably different. Conversely, hot molding using 4 times gas release with intermittent hot pressing for 15 seconds decreased flexural strength of composite. Hot molding using 2, 4, and 8 times gas release with intermittent hot pressing for 10 seconds also had no effect on increasing flexural strength. Increasing of flexural strength of composite was obtained only by using 6 times gas release with intermittent hot pressing for 10 seconds.
Heintze, Siegward D; Ilie, Nicoleta; Hickel, Reinhard; Reis, Alessandra; Loguercio, Alessandro; Rousson, Valentin
2017-03-01
To evaluate a range of mechanical parameters of composite resins and compare the data to the frequency of fractures and wear in clinical studies. Based on a search of PubMed and SCOPUS, clinical studies on posterior composite restorations were investigated with regard to bias by two independent reviewers using Cochrane Collaboration's tool for assessing risk of bias in randomized trials. The target variables were chipping and/or fracture, loss of anatomical form (wear) and a combination of both (summary clinical index). These outcomes were modelled by time and material in a linear mixed effect model including random study and experiment effects. The laboratory data from one test institute were used: flexural strength, flexural modulus, compressive strength, and fracture toughness (all after 24-h storage in distilled water). For some materials flexural strength data after aging in water/saliva/ethanol were available. Besides calculating correlations between clinical and laboratory outcomes, we explored whether a model including a laboratory predictor dichotomized at a cut-off value better predicted a clinical outcome than a linear model. A total of 74 clinical experiments from 45 studies were included involving 31 materials for which laboratory data were also available. A weak positive correlation between fracture toughness and clinical fractures was found (Spearman rho=0.34, p=0.11) in addition to a moderate and statistically significant correlation between flexural strength and clinical wear (Spearman rho=0.46, p=0.01). When excluding those studies with "high" risk of bias (n=18), the correlations were generally weaker with no statistically significant correlation. For aging in ethanol, a very strong correlation was found between flexural strength decrease and clinical index, but this finding was based on only 7 materials (Spearman rho=0.96, p=0.0001). Prediction was not consistently improved with cutoff values. Correlations between clinical and laboratory outcomes were moderately positive with few significant results, fracture toughness being correlated with clinical fractures and flexural strength with clinical wear. Whether artificial aging enhances the prognostic value needs further investigations. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
García-Espinosa, Victoria; Curcio, Santiago; Castro, Juan Manuel; Arana, Maite; Giachetto, Gustavo; Chiesa, Pedro; Zócalo, Yanina
2016-01-01
Aim. To analyze if childhood obesity associates with changes in elastic, transitional, and/or muscular arteries' stiffness. Methods. 221 subjects (4–15 years, 92 females) were assigned to normal weight (NW, n = 137) or obesity (OB, n = 84) groups, considering their body mass index z-score. Age groups were defined: 4–8; 8–12; 12–15 years old. Carotid, femoral, and brachial artery local stiffness was determined through systodiastolic pressure-diameter and stress-strain relationships. To this end, arterial diameter and peripheral and aortic blood pressure (BP) levels and waveforms were recorded. Carotid-femoral, femoropedal, and carotid-radial pulse wave velocities were determined to evaluate aortic, lower-limb, and upper-limb regional arterial stiffness, respectively. Correlation analysis between stiffness parameters and BP was done. Results. Compared to NW, OB subjects showed higher peripheral and central BP and carotid and femoral stiffness, reaching statistical significance in subjects aged 12 and older. Arterial stiffness differences disappeared when levels were normalized for BP. There were no differences in intrinsic arterial wall stiffness (elastic modulus), BP stiffness relationships, and regional stiffness parameters. Conclusion. OB associates with BP-dependent and age-related increase in carotid and femoral (but not brachial) stiffness. Stiffness changes would not be explained by intrinsic arterial wall alterations but could be associated with the higher BP levels observed in obese children. PMID:27066273
Analysis of Flexible Car Body of Straddle Monorail Vehicle
NASA Astrophysics Data System (ADS)
Zhong, Yuanmu
2018-03-01
Based on the finite element model of straddle monorail vehicle, a rigid-flexible coupling dynamic model considering vehicle body’s flexibility is established. The influence of vertical stiffness and vertical damping of the running wheel on the modal parameters of the car body is analyzed. The effect of flexible car body on modal parameters and vehicle ride quality is also studied. The results show that when the vertical stiffness of running wheel is less than 1 MN / m, the car body bounce and pitch frequency increase with the increasing of the vertical stiffness of the running wheel, when the running wheel vertical stiffness is 1MN / m or more, car body bounce and pitch frequency remained unchanged; When the vertical stiffness of the running wheel is below 1.8 MN / m, the vehicle body bounce and pitch damping ratio increase with the increasing of the vertical stiffness of the running wheel; When the running wheel vertical stiffness is 1.8MN / m or more, the car body bounce and pitch damping ratio remained unchanged; The running wheel vertical damping on the car body bounce and pitch frequency has no effect; Car body bounce and pitch damping ratio increase with the increasing of the vertical damping of the running wheel. The flexibility of the car body has no effect on the modal parameters of the car, which will improve the vehicle ride quality index.
Experimental Challenges to Stiffness as a Transport Paradigm
NASA Astrophysics Data System (ADS)
Luce, T. C.
2017-10-01
Transport in plasmas is treated experimentally as a relationship between gradients and fluxes in analogy to the random-walk problem. Gyrokinetic models often predict strong increases in local flux for small increases in local gradient when above a threshold, holding all other parameters fixed. This has been named `stiffness'. The radial scalelength is then expected to vary little with source strength as a result of high stiffness. To probe the role of ExB shearing on stiffness in the DIII-D tokamak, two neutral beam injection power scans in H-mode plasmas were specially crafted-one with constant, low torque and one with increasing torque. The ion heat, electron heat, and ion toroidal momentum transport do not show expected signatures of stiffness, while the ion particle transport does. The ion heat transport shows the clearest discrepancy; the normalized heat flux drops with increasing inverse ion temperature scalelength. ExB shearing affects the transport magnitude, but not the scalelength dependence. Linear gyrofluid (TGLF) and nonlinear gyrokinetic (GYRO) predictions show stiff ion heat transport around the experimental profiles. The ion temperature gradient required to match the ion heat flux with increasing auxiliary power is not correctly described by TGLF, even when parameters are varied within the experimental uncertainties. TGLF also underpredicts transport at smaller radii, but overpredicts transport at larger radii. Independent of the theory/experiment comparison, it is not clear that the theoretical definition of stiffness yields any prediction about parameter scans such as the power scans here, because the quantities that must be held fixed to quantify stiffness are varied. A survey of recent literature indicated that profile resilience is routinely attributed to stiffness, but simple model calculations show profile resilience does not imply stiffness. Taken together, these observations challenge the use of local stiffness as a paradigm for explaining global transport behavior. Work supported by US DOE under DE-FC02-04ER54698.
Mossahebi, Sina; Kovács, Sándor J
2014-01-01
Although the electrophysiologic derangement responsible for atrial fibrillation (AF) has been elucidated, how AF remodels the ventricular chamber and affects diastolic function (DF) has not been fully characterized. The previously validated Parametrized Diastolic Filling (PDF) formalism models suction-initiated filling kinematically and generates error-minimized fits to E-wave contours using unique load (x o ), relaxation (c), and stiffness (k) parameters. It predicts that E-wave deceleration time (DT) is a function of both stiffness and relaxation. Ascribing DT s to stiffness and DTr to relaxation such that DT=DT s +DT r is legitimate because of causality and their predicted and observed high correlation (r=0.82 and r=0.94) with simultaneous (diastatic) chamber stiffness (dP/dV) and isovolumic relaxation (tau), respectively. We analyzed simultaneous echocardiography-cardiac catheterization data and compared 16 age matched, chronic AF subjects to 16, normal sinus rhythm (NSR) subjects (650 beats). All subjects had diastatic intervals. Conventional DF parameters (DT, AT, E peak , E dur , E-VTI, E/E') and E-wave derived PDF parameters (c, k, DT s , DT r ) were compared. Total DT and DT s , DT r in AF were shorter than in NSR (p<0.005), chamber stiffness, (k) in AF was higher than in NSR (p<0.001). For NSR, 75% of DT was due to stiffness and 25% was due to relaxation whereas for AF 81% of DT was due to stiffness and 19% was due to relaxation (p<0.005). We conclude that compared to NSR, increased chamber stiffness is one measurable consequence of chamber remodeling in chronic, rate controlled AF. A larger fraction of E-wave DT in AF is due to stiffness compared to NSR. By trending individual subjects, this method can elucidate and characterize the beneficial or adverse long-term effects on chamber remodeling due to alternative therapies in terms of chamber stiffness and relaxation.
Wu, Hsien-Tsai; Liu, Cyuan-Cin; Lin, Po-Hsun; Chung, Hui-Ming; Liu, Ming-Chien; Yip, Hon-Kan; Liu, An-Bang; Sun, Cheuk-Kwan
2010-11-01
Although contour analysis of pulse waves has been proposed as a non-invasive means in assessing arterial stiffness in atherosclerosis, accurate determination of the conventional parameters is usually precluded by distorted waveforms in the aged and atherosclerotic objects. We aimed at testing reliable indices in these patient populations. Digital volume pulse (DVP) curve was obtained from 428 subjects recruited from a health screening program at a single medical center from January 2007 to July 2008. Demographic data, blood pressure, and conventional parameters for contour analysis including pulse wave velocity (PWV), crest time (CT), stiffness index (SI), and reflection index (RI) were recorded. Two indices including normalized crest time (NCT) and crest time ratio (CTR) were also analysed and compared with the known parameters. Though ambiguity of dicrotic notch precluded an accurate determination of the two key conventional parameters for assessing arterial stiffness (i.e. SI and RI), NCT and CTR were unaffected because the sum of CT and T(DVP) (i.e. the duration between the systolic and diastolic peak) tended to remain constant. NCT and CTR also correlated significantly with age, systolic and diastolic blood pressure, PWV, SI and RI (all P<0.01). NCT and CTR not only showed significant positive correlations with the conventional parameters for assessment of atherosclerosis (i.e. SI, RI, and PWV), but they also are of particular value in assessing degree of arterial stiffness in subjects with indiscernible peak of diastolic wave that precludes the use of conventional parameters in waveform contour analysis. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Integrated tuned vibration absorbers: a theoretical study.
Gardonio, Paolo; Zilletti, Michele
2013-11-01
This article presents a simulation study on two integrated tuned vibration absorbers (TVAs) designed to control the global flexural vibration of lightly damped thin structures subject to broad frequency band disturbances. The first one consists of a single axial switching TVA composed by a seismic mass mounted on variable axial spring and damper elements so that the characteristic damping and natural frequency of the absorber can be switched iteratively to control the resonant response of three flexural modes of the hosting structure. The second one consists of a single three-axes TVA composed by a seismic mass mounted on axial and rotational springs and dampers, which are arranged in such a way that the suspended mass is characterized by uncoupled heave and pitch-rolling vibrations. In this case the three damping and natural frequency parameters of the absorber are tuned separately to control three flexural modes of the hosting structure. The simulation study shows that the proposed single-unit absorbers produce, respectively, 5.3 and 8.7 dB reductions of the global flexural vibration of a rectangular plate between 20 and 120 Hz.
Danquechin Dorval, Antoine; Meredieu, Céline; Danjon, Frédéric
2016-01-01
Background and Aims Storms can cause huge damage to European forests. Even pole-stage trees with 80-cm rooting depth can topple. Therefore, good anchorage is needed for trees to survive and grow up from an early age. We hypothesized that root architecture is a predominant factor determining anchorage failure caused by strong winds. Methods We sampled 48 seeded or planted Pinus pinaster trees of similar aerial size from four stands damaged by a major storm 3 years before. The trees were gathered into three classes: undamaged, leaning and heavily toppled. After uprooting and 3D digitizing of their full root architectures, we computed the mechanical characteristics of the main components of the root system from our morphological measurements. Key Results Variability in root architecture was quite large. A large main taproot, either short and thick or long and thin, and guyed by a large volume of deep roots, was the major component that prevented stem leaning. Greater shallow root flexural stiffness mainly at the end of the zone of rapid taper on the windward side also prevented leaning. Toppling in less than 90-cm-deep soil was avoided in trees with a stocky taproots or with a very big leeward shallow root. Toppled trees also had a lower relative root biomass – stump excluded – than straight trees. Conclusions It was mainly the flexural stiffness of the central part of the root system that secured anchorage, preventing a weak displacement of the stump. The distal part of the longest taproot and attached deep roots may be the only parts of the root system contributing to anchorage through their maximum tensile load. Several designs provided good anchorage, depending partly on available soil depth. Pole-stage trees are in-between the juvenile phase when they fail by toppling and the mature phase when they fail by uprooting. PMID:27456136
Flexural analysis of palm fiber reinforced hybrid polymer matrix composite
NASA Astrophysics Data System (ADS)
Venkatachalam, G.; Gautham Shankar, A.; Raghav, Dasarath; Santhosh Kiran, R.; Mahesh, Bhargav; Kumar, Krishna
2015-07-01
Uncertainty in availability of fossil fuels in the future and global warming increased the need for more environment friendly materials. In this work, an attempt is made to fabricate a hybrid polymer matrix composite. The blend is a mixture of General Purpose Resin and Cashew Nut Shell Liquid, a natural resin extracted from cashew plant. Palm fiber, which has high strength, is used as reinforcement material. The fiber is treated with alkali (NaOH) solution to increase its strength and adhesiveness. Parametric study of flexure strength is carried out by varying alkali concentration, duration of alkali treatment and fiber volume. Taguchi L9 Orthogonal array is followed in the design of experiments procedure for simplification. With the help of ANOVA technique, regression equations are obtained which gives the level of influence of each parameter on the flexure strength of the composite.
Relationship between increased carotid artery stiffness and idiopathic subjective tinnitus.
Bayraktar, C; Taşolar, S
2017-05-01
Tinnitus is defined as perception of sound with no external stimulus, and can separate into pulsatile and non-pulsatile types. Arterial stiffness is a parameter that can predict the cardiovascular event and associated with incidence of stroke. It has been shown that increased arterial stiffness may lead to microvascular damage in brain. Our aim was to assess the arterial stiffness of the carotid system in the development and severity of idiopathic subjective tinnitus. Forty subjective tinnitus patients and 40 age- and sex-matched controls were enrolled in the study. The parameters obtained from the participants included pure tone hearing (dB), serum lipid profile (mg/dl), fasting glucose (mg/dl), blood pressure (mmHg), and body mass index (BMI, kg/m 2 ). The common carotid artery (CCA) stiffness index, Young's elastic modulus (YEM), common carotid intima-media thickness (CIMT), peak systolic velocity (PSV), end-diastolic velocity (EDV), resistive index (RI), pulsatility index (PI), vessel diameter, mean velocity (MV), and volume flow (VF) were measured in both the right and left common carotid arteries in both groups. The CCA stiffness index, YEM measurements, right CIMT, and left PI were found to be significantly higher in the patients than those in the control group (p < 0.05). With regard to the severity of the tinnitus and the patient characteristics, there was a significant positive correlation with the CCA stiffness index, YEM measurements, left CIMT, and neutrophil-to-lymphocyte ratio (NLR). However, only the right and left CCA stiffness parameters were found to be statistically significant in the multivariate analysis as independent predictors of a moderate to high degree of tinnitus. The increased stiffness index of the common carotid arteries was significantly associated with the formation and severity of tinnitus. Therefore, an assessment of the carotideal system may be helpful in these patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelson, Stacy; English, Shawn; Briggs, Timothy
Fiber-reinforced composite materials offer light-weight solutions to many structural challenges. In the development of high-performance composite structures, a thorough understanding is required of the composite materials themselves as well as methods for the analysis and failure prediction of the relevant composite structures. However, the mechanical properties required for the complete constitutive definition of a composite material can be difficult to determine through experimentation. Therefore, efficient methods are necessary that can be used to determine which properties are relevant to the analysis of a specific structure and to establish a structure's response to a material parameter that can only be definedmore » through estimation. The objectives of this paper deal with demonstrating the potential value of sensitivity and uncertainty quantification techniques during the failure analysis of loaded composite structures; and the proposed methods are applied to the simulation of the four-point flexural characterization of a carbon fiber composite material. Utilizing a recently implemented, phenomenological orthotropic material model that is capable of predicting progressive composite damage and failure, a sensitivity analysis is completed to establish which material parameters are truly relevant to a simulation's outcome. Then, a parameter study is completed to determine the effect of the relevant material properties' expected variations on the simulated four-point flexural behavior as well as to determine the value of an unknown material property. This process demonstrates the ability to formulate accurate predictions in the absence of a rigorous material characterization effort. Finally, the presented results indicate that a sensitivity analysis and parameter study can be used to streamline the material definition process as the described flexural characterization was used for model validation.« less
Effects of railway track design on the expected degradation: Parametric study on energy dissipation
NASA Astrophysics Data System (ADS)
Sadri, Mehran; Steenbergen, Michaël
2018-04-01
This paper studies the effect of railway track design parameters on the expected long-term degradation of track geometry. The study assumes a geometrically perfect and straight track along with spatial invariability, except for the presence of discrete sleepers. A frequency-domain two-layer model is used of a discretely supported rail coupled with a moving unsprung mass. The susceptibility of the track to degradation is objectively quantified by calculating the mechanical energy dissipated in the substructure under a moving train axle for variations of different track parameters. Results show that, apart from the operational train speed, the ballast/substructure stiffness is the most significant parameter influencing energy dissipation. Generally, the degradation increases with the train speed and with softer substructures. However, stiff subgrades appear more sensitive to particular train velocities, in a regime which is mostly relevant for conventional trains (100-200 km/h) and less for high-speed operation, where a stiff subgrade is always favorable and can reduce the sensitivity to degradation substantially, with roughly a factor up to 7. Also railpad stiffness, sleeper distance and rail cross-sectional properties are found to have considerable effect, with higher expected degradation rates for increasing railpad stiffness, increasing sleeper distance and decreasing rail profile bending stiffness. Unsprung vehicle mass and sleeper mass have no significant influence, however, only against the background of the assumption of an idealized (invariant and straight) track. Apart from dissipated mechanical energy, the suitability of the dynamic track stiffness is explored as an engineering parameter to assess the sensitivity to degradation. It is found that this quantity is inappropriate to assess the design of an idealized track.
Liu, Juan; Ando, Hiroshi
2016-01-01
Most real-world events stimulate multiple sensory modalities simultaneously. Usually, the stiffness of an object is perceived haptically. However, auditory signals also contain stiffness-related information, and people can form impressions of stiffness from the different impact sounds of metal, wood, or glass. To understand whether there is any interaction between auditory and haptic stiffness perception, and if so, whether the inferred material category is the most relevant auditory information, we conducted experiments using a force-feedback device and the modal synthesis method to present haptic stimuli and impact sound in accordance with participants’ actions, and to modulate low-level acoustic parameters, i.e., frequency and damping, without changing the inferred material categories of sound sources. We found that metal sounds consistently induced an impression of stiffer surfaces than did drum sounds in the audio-only condition, but participants haptically perceived surfaces with modulated metal sounds as significantly softer than the same surfaces with modulated drum sounds, which directly opposes the impression induced by these sounds alone. This result indicates that, although the inferred material category is strongly associated with audio-only stiffness perception, low-level acoustic parameters, especially damping, are more tightly integrated with haptic signals than the material category is. Frequency played an important role in both audio-only and audio-haptic conditions. Our study provides evidence that auditory information influences stiffness perception differently in unisensory and multisensory tasks. Furthermore, the data demonstrated that sounds with higher frequency and/or shorter decay time tended to be judged as stiffer, and contact sounds of stiff objects had no effect on the haptic perception of soft surfaces. We argue that the intrinsic physical relationship between object stiffness and acoustic parameters may be applied as prior knowledge to achieve robust estimation of stiffness in multisensory perception. PMID:27902718
Gurram, Ravi; Krishna, C H Vamsi; Reddy, K Mahendranadh; Reddy, G V K Mohan; Shastry, Y Mahadev
2014-12-01
The study was undertaken to evaluate the biaxial flexural strength, biaxial flexural strength after etching with 9 % HF acid and fracture toughness of three commonly used pressable all ceramic core materials. Ninety glass ceramic specimens were fabricated from three commercially available leucite based core ceramic material (1) Esthetic Empress, (2) Cergo, and (3) Performance Plus. Thirty discs of each material were divided into three groups of 10 discs each. Biaxial flexural strength (30 discs,) Biaxial flexural strength for samples treated with 9 % HF acid (30 discs) and fracture toughness (30 discs) were evaluated. Core material Performance Plus had the lowest biaxial strength of 124.89 MPa, Cergo had strength of 152.22 MPa and the highest value of 163.95 was reported for Esthetic Empress. For samples treated 9 % HF, Performance Plus had the lowest biaxial strength of 98.37 MPa, Cergo had strength of 117.42 MPa and the highest value of 143.74 was reported for Esthetic Empress. Core material Performance Plus had the lowest fracture toughness of 1.063 MPa, Cergo had strength of 1.112 MPa and the highest value of 1.225 was reported for Esthetic Empress. The results shows that Esthetic Empress had better mechanical properties compared to Cergo had Performance Plus in relation to the parameters tested.
NASA Technical Reports Server (NTRS)
Miller, D. W.
1981-01-01
A prototype of a linear inertial reaction actuation (damper) device employing a flexure-pivoted reaction (proof) mass is discussed. The mass is driven by an electromechanic motor using a dc electromagnetic field and an ac electromagnetic drive. During the damping process, the actuator dissipates structural kinetic energy as heat through electromagnetic damping. A model of the inertial, stiffness and damping properties is presented along with the characteristic differential equations describing the coupled response of the actuator and structure. The equations, employing the dynamic coefficients, are oriented in the form of a feedback control network in which distributed sensors are used to dictate actuator response leading to a specified amount of structural excitation or damping.
Development of a precision, six-axis laboratory dynamometer
NASA Technical Reports Server (NTRS)
Champagne, P. J.; Cordova, S. A.; Jacoby, M. S.; Lorell, K. R.
1992-01-01
This paper describes the design, fabrication, test, and operation of a unique six axis force/torque dynamometer The specimen table used to hold components under test is supported in a full six axis kinematic mount. Support struts fabricated from high strength steel with special integral two axis flexures link the specimen table to the load cell transducers. Realtime force/torque coordinate transform, root mean squared calculation, and data averaging, and color six axis display with controllable scaling are provided by a specially programmed desktop computer. The extensive structural analysis and design optimization required to obtain a stiff, well damped, lightweight structure is described in detail. Geometric optimization of the kinematic mount and fabrication details of the struts are also described.
NASA Technical Reports Server (NTRS)
Waas, A. M.; Knauss, W. G.; Babcock, C. D., Jr.
1990-01-01
Mechanisms of failure in laminates in the presence of a stress raiser were experimentally studied. The damage initiation and propagation throughout the entire load history were examined via real-time holographic interferometry and photomicrography of the hole surface. Multilayered composite flat plates made of T300/BP907 and IM7/8551-7 were tested. It is shown that the failure is initiated as a localized instability in the 0-deg plies at the hole surface approximately at right angles to the loading direction. A series of events is described which culminates in the complete loss of flexural stiffness of each of the delaminated portions, leading to catastrophic failure of the plate.
Shu, Deming; Shvydko, Yuri; Stoupin, Stanislav A.; Khachatryan, Ruben; Goetze, Kurt A.; Roberts, Timothy
2015-04-14
A method and an ultrahigh-resolution spectrometer including a precision mechanical structure for positioning inelastic X-ray scattering optics are provided. The spectrometer includes an X-ray monochromator and an X-ray analyzer, each including X-ray optics of a collimating (C) crystal, a pair of dispersing (D) element crystals, anomalous transmission filter (F) and a wavelength (W) selector crystal. A respective precision mechanical structure is provided with the X-ray monochromator and the X-ray analyzer. The precision mechanical structure includes a base plate, such as an aluminum base plate; positioning stages for D-crystal alignment; positioning stages with an incline sensor for C/F/W-crystal alignment, and the positioning stages including flexure-based high-stiffness structure.
Universal deformation pathways and flexural hardening of nanoscale 2D-material standing folds
NASA Astrophysics Data System (ADS)
Chacham, Helio; Barboza, Ana Paula M.; de Oliveira, Alan B.; de Oliveira, Camilla K.; Batista, Ronaldo J. C.; Neves, Bernardo R. A.
2018-03-01
In the present work, we use atomic force microscopy nanomanipulation of 2D-material standing folds to investigate their mechanical deformation. Using graphene, h-BN and talc nanoscale wrinkles as testbeds, universal force-strain pathways are clearly uncovered and well-accounted for by an analytical model. Such universality further enables the investigation of each fold bending stiffness κ as a function of its characteristic height h 0. We observe a more than tenfold increase of κ as h 0 increases in the 10-100 nm range, with power-law behaviors of κ versus h 0 with exponents larger than unity for the three materials. This implies anomalous scaling of the mechanical responses of nano-objects made from these materials.
Felfel, R M; Ahmed, I; Parsons, A J; Rudd, C D
2013-01-01
Use of bioresorbable screws could eliminate disadvantages associated with metals such as removal operations, corrosion, MRI interference and stress shielding. Mechanical properties of bioresorbable polymers alone are insufficient for load bearing applications application as screws. Thus, reinforcement is necessary to try and match or surpass the mechanical properties of cortical bone. Phosphate based glass fibres were used to reinforce polylactic acid (PLA) in order to produce unidirectionally aligned (UD) and unidirectionally plus randomly distributed (UD/RM) composite screws (P40 UD and P40 UD/RM). The maximum flexural and push-out properties for the composite screws (P40 UD and P40 UD/RM) increased by almost 100% in comparison with the PLA screws. While the pull-out strength and stiffness of the headless composite screws were ∼80% (strength) and ∼130% (stiffness) higher than for PLA, those with heads exhibited properties lower than those for PLA alone as a result of failure at the heads. An increase in the maximum shear load and stiffness for the composite screws (∼30% and ∼40%) in comparison to the PLA screws was also seen. Maximum torque for the PLA screws was ∼1000 mN m, while that for the composite screws were slightly lower. The SEM micrographs for P40 UD and P40 UD/RM screws revealed small gaps around the fibres, which were suggested to be due to buckling of the UD fibres during the manufacturing process. Copyright © 2012 Elsevier Ltd. All rights reserved.
A new method for measuring the rotational accuracy of rolling element bearings
NASA Astrophysics Data System (ADS)
Chen, Ye; Zhao, Xiangsong; Gao, Weiguo; Hu, Gaofeng; Zhang, Shizhen; Zhang, Dawei
2016-12-01
The rotational accuracy of a machine tool spindle has critical influence upon the geometric shape and surface roughness of finished workpiece. The rotational performance of the rolling element bearings is a main factor which affects the spindle accuracy, especially in the ultra-precision machining. In this paper, a new method is developed to measure the rotational accuracy of rolling element bearings of machine tool spindles. Variable and measurable axial preload is applied to seat the rolling elements in the bearing races, which is used to simulate the operating conditions. A high-precision (radial error is less than 300 nm) and high-stiffness (radial stiffness is 600 N/μm) hydrostatic reference spindle is adopted to rotate the inner race of the test bearing. To prevent the outer race from rotating, a 2-degrees of freedom flexure hinge mechanism (2-DOF FHM) is designed. Correction factors by using stiffness analysis are adopted to eliminate the influences of 2-DOF FHM in the radial direction. Two capacitive displacement sensors with nano-resolution (the highest resolution is 9 nm) are used to measure the radial error motion of the rolling element bearing, without separating the profile error as the traditional rotational accuracy metrology of the spindle. Finally, experimental measurements are performed at different spindle speeds (100-4000 rpm) and axial preloads (75-780 N). Synchronous and asynchronous error motion values are evaluated to demonstrate the feasibility and repeatability of the developed method and instrument.
Multiple nodes transfer alignment for airborne missiles based on inertial sensor network
NASA Astrophysics Data System (ADS)
Si, Fan; Zhao, Yan
2017-09-01
Transfer alignment is an important initialization method for airborne missiles because the alignment accuracy largely determines the performance of the missile. However, traditional alignment methods are limited by complicated and unknown flexure angle, and cannot meet the actual requirement when wing flexure deformation occurs. To address this problem, we propose a new method that uses the relative navigation parameters between the weapons and fighter to achieve transfer alignment. First, in the relative inertial navigation algorithm, the relative attitudes and positions are constantly computed in wing flexure deformation situations. Secondly, the alignment results of each weapon are processed using a data fusion algorithm to improve the overall performance. Finally, the feasibility and performance of the proposed method were evaluated under two typical types of deformation, and the simulation results demonstrated that the new transfer alignment method is practical and has high-precision.
NASA Astrophysics Data System (ADS)
Xu, Donghong; Xue, Fei
2017-12-01
We theoretically study cooling of flexural modes of a mechanical oscillator by Bose-Einstein-condensate (BEC) atoms (Rb87) trapped in a magnetic trap. The mechanical oscillator with a tiny magnet attached on one of its free ends produces an oscillating magnetic field. When its oscillating frequency matches certain hyperfine Zeeman energy of Rb87 atoms, the trapped BEC atoms are coupled out of the magnetic trap by the mechanical oscillator, flying away from the trap with stolen energy from the mechanical oscillator. Thus the mode temperature of the mechanical oscillator is reduced. The mode temperature of the steady state of mechanical oscillator, measured by the mean steady-state phonon number in the flexural mode of the mechanical oscillator, is analyzed. It is found that ground state (phonon number less than 1) may be accessible with optimal parameters of the hybrid system of mechanical oscillator and trapped BEC atoms.
Tanaka, Midori; Sugawara, Motoaki; Ogasawara, Yasuo; Izumi, Tadafumi; Niki, Kiyomi; Kajiya, Fumihiko
2013-04-01
Aerobic exercise has been reported to be associated with reduced arterial stiffness. However, the intensity, duration, and frequency of aerobic exercise required to improve arterial stiffness have not been established. In addition, most reports base their conclusions on changes in pulse wave velocity, which is an indirect index of arterial stiffness. We studied the effects of short-term, intermittent, moderate-intensity exercise training on arterial stiffness based on measurements of the stiffness parameter (β) and pressure-strain elastic modulus (E p), which are direct indices of regional arterial stiffness. A total of 25 young healthy volunteers (18 men) were recruited. By use of ultrasonic diagnostic equipment we measured β and E p of the carotid artery before and after 8 weeks of exercise training. After exercise training, systolic pressure (P s), diastolic pressure (P d), pulse pressure, systolic arterial diameter (D s), and diastolic arterial diameter (D d) did not change significantly. However, the pulsatile change in diameter ((D s - D d)/D d) increased significantly, and β and E p decreased significantly. For healthy young subjects, β and E p were reduced by intermittent, moderate-intensity exercise training for only 8 weeks.
Guarín, Diego L.; Kearney, Robert E.
2017-01-01
Dynamic joint stiffness determines the relation between joint position and torque, and plays a vital role in the control of posture and movement. Dynamic joint stiffness can be quantified during quasi-stationary conditions using disturbance experiments, where small position perturbations are applied to the joint and the torque response is recorded. Dynamic joint stiffness is composed of intrinsic and reflex mechanisms that act and change together, so that nonlinear, mathematical models and specialized system identification techniques are necessary to estimate their relative contributions to overall joint stiffness. Quasi-stationary experiments have demonstrated that dynamic joint stiffness is heavily modulated by joint position and voluntary torque. Consequently, during movement, when joint position and torque change rapidly, dynamic joint stiffness will be Time-Varying (TV). This paper introduces a new method to quantify the TV intrinsic and reflex components of dynamic joint stiffness during movement. The algorithm combines ensemble and deterministic approaches for estimation of TV systems; and uses a TV, parallel-cascade, nonlinear system identification technique to separate overall dynamic joint stiffness into intrinsic and reflex components from position and torque records. Simulation studies of a stiffness model, whose parameters varied with time as is expected during walking, demonstrated that the new algorithm accurately tracked the changes in dynamic joint stiffness using as little as 40 gait cycles. The method was also used to estimate the intrinsic and reflex dynamic ankle stiffness from an experiment with a healthy subject during which ankle movements were imposed while the subject maintained a constant muscle contraction. The method identified TV stiffness model parameters that predicted the measured torque very well, accounting for more than 95% of its variance. Moreover, both intrinsic and reflex dynamic stiffness were heavily modulated through the movement in a manner that could not be predicted from quasi-stationary experiments. The new method provides the tool needed to explore the role of dynamic stiffness in the control of movement. PMID:28649196
NASA Astrophysics Data System (ADS)
Wang, Jing; Shen, Huoming; Zhang, Bo; Liu, Juan; Zhang, Yingrong
2018-07-01
We investigate the transverse free vibration behaviour of axially moving nanobeams based on the nonlocal strain gradient theory. Considering the geometrical nonlinearity, which takes the form of von Kármán strains, the coupled plane motion equations and related boundary conditions of a new size-dependent beam model of Euler-Bernoulli type are developed using the generalized Hamilton principle. Using the simply supported axially moving nanobeams as an example, the complex modal analysis method is adopted to solve the governing equation; then, the effect of the order of modal truncation on the natural frequencies is discussed. Subsequently, the roles of the nonlocal parameter, material characteristic parameter, axial speed, stiffness and axial support rigidity parameter on the free vibration are comprehensively addressed. The material characteristic parameter induces the stiffness hardening of nanobeams, while the nonlocal parameter induces stiffness softening. In addition, the roles of small-scale parameters on the flutter critical velocity and stability are explained.
NASA Astrophysics Data System (ADS)
Zheng, Yisheng; Zhang, Xinong; Luo, Yajun; Zhang, Yahong; Xie, Shilin
2018-02-01
By now, many translation quasi-zero stiffness (QZS) mechanisms have been proposed to overcome the restriction between the isolation frequency range and the load bearing capacity of linear isolators. The couplings of rotor systems undertake the functions of transmitting static driving torque and isolating disturbing torque simultaneously, which creates the demand of torsion QZS mechanisms. Hence a QZS coupling is presented in this paper, where a torsion magnetic spring (TMS) composed of two coaxial ring magnet arrangements in repulsive configuration is employed to produce negative torsion stiffness to counteract the positive stiffness of a rubber spring. In this paper, the expressions of magnetic torque and stiffness are given firstly and verified by finite element simulations; and the effect of geometric parameters of the TMS on its stiffness characteristic is analyzed in detail, which contributes to the optimal design of the TMS. Then dynamic analysis of the QZS coupling is performed and the analytical expression of the torque transmissibility is achieved based on the Harmonic Balance Method. Finally, simulation of the torque transmissibility is carried out to reveal how geometric parameters of the TMS affect the isolation performance.
Nam, Kanghyun
2015-11-11
This article presents methods for estimating lateral vehicle velocity and tire cornering stiffness, which are key parameters in vehicle dynamics control, using lateral tire force measurements. Lateral tire forces acting on each tire are directly measured by load-sensing hub bearings that were invented and further developed by NSK Ltd. For estimating the lateral vehicle velocity, tire force models considering lateral load transfer effects are used, and a recursive least square algorithm is adapted to identify the lateral vehicle velocity as an unknown parameter. Using the estimated lateral vehicle velocity, tire cornering stiffness, which is an important tire parameter dominating the vehicle's cornering responses, is estimated. For the practical implementation, the cornering stiffness estimation algorithm based on a simple bicycle model is developed and discussed. Finally, proposed estimation algorithms were evaluated using experimental test data.
Gross, R; Robertson, J; Leboeuf, F; Hamel, O; Brochard, S; Perrouin-Verbe, B
2017-02-01
Stiff knee gait is a troublesome gait disturbance related to spastic paresis, frequently associated with overactivity of the rectus femoris muscle in the swing phase of gait. The aim of this study was to assess the short-term effects of rectus femoris neurotomy for the treatment of spastic stiff-knee gait in patients with hemiparesis. An Intervention study (before-after trial) with an observational design was carried out in a university hospital. Seven ambulatory patients with hemiparesis of spinal or cerebral origin and spastic stiff-knee gait, which had previously been improved by botulinum toxin injections, were proposed a selective neurotomy of the rectus femoris muscle. A functional evaluation (Functional Ambulation Classification and maximal walking distance), clinical evaluation (spasticity - Ashworth scale and Duncan-Ely test, muscle strength - Medical Research Council scale), and quantitative gait analysis (spatiotemporal parameters, stiff knee gait-related kinematic and kinetic parameters, and dynamic electromyography of rectus femoris) were performed as outcome measures, before and 3 months after rectus femoris neurotomy. Compared with preoperative values, there was a significant increase in maximal walking distance, gait speed, and stride length at 3 months. All kinematic parameters improved, and the average early swing phase knee extension moment decreased. The duration of the rectus femoris burst decreased post-op. This study is the first to show that rectus femoris neurotomy helps to normalise muscle activity during gait, and results in improvements in kinetic, kinematic, and functional parameters in patients with spastic stiff knee gait. Copyright © 2016 Elsevier B.V. All rights reserved.
Estimation of Quasi-Stiffness and Propulsive Work of the Human Ankle in the Stance Phase of Walking
Shamaei, Kamran; Sawicki, Gregory S.; Dollar, Aaron M.
2013-01-01
Characterizing the quasi-stiffness and work of lower extremity joints is critical for evaluating human locomotion and designing assistive devices such as prostheses and orthoses intended to emulate the biological behavior of human legs. This work aims to establish statistical models that allow us to predict the ankle quasi-stiffness and net mechanical work for adults walking on level ground. During the stance phase of walking, the ankle joint propels the body through three distinctive phases of nearly constant stiffness known as the quasi-stiffness of each phase. Using a generic equation for the ankle moment obtained through an inverse dynamics analysis, we identify key independent parameters needed to predict ankle quasi-stiffness and propulsive work and also the functional form of each correlation. These parameters include gait speed, ankle excursion, and subject height and weight. Based on the identified form of the correlation and key variables, we applied linear regression on experimental walking data for 216 gait trials across 26 subjects (speeds from 0.75–2.63 m/s) to obtain statistical models of varying complexity. The most general forms of the statistical models include all the key parameters and have an R2 of 75% to 81% in the prediction of the ankle quasi-stiffnesses and propulsive work. The most specific models include only subject height and weight and could predict the ankle quasi-stiffnesses and work for optimal walking speed with average error of 13% to 30%. We discuss how these models provide a useful framework and foundation for designing subject- and gait-specific prosthetic and exoskeletal devices designed to emulate biological ankle function during level ground walking. PMID:23555839
Design of Tailored Non-Crimp Fabrics Based on Stitching Geometry
NASA Astrophysics Data System (ADS)
Krieger, Helga; Gries, Thomas; Stapleton, Scott E.
2018-02-01
Automation of the preforming process brings up two opposing requirements for the used engineering fabric. On the one hand, the fabric requires a sufficient drapeability, or low shear stiffness, for forming into double-curved geometries; but on the other hand, the fabric requires a high form stability, or high shear stiffness, for automated handling. To meet both requirements tailored non-crimp fabrics (TNCFs) are proposed. While the stitching has little structural influence on the final part, it virtually dictates the TNCFs local capability to shear and drape over a mold during preforming. The shear stiffness of TNCFs is designed by defining the local stitching geometry. NCFs with chain stitch have a comparatively high shear stiffness and NCFs with a stitch angle close to the symmetry stitch angle have a very low shear stiffness. A method to design the component specific local stitching parameters of TNCFs is discussed. For validation of the method, NCFs with designed tailored stitching parameters were manufactured and compared to benchmark NCFs with uniform stitching parameters. The designed TNCFs showed both, generally a high form stability and in locally required zones a good drapeability, in drape experiments over an elongated hemisphere.
Flexural plate wave devices fabricated from silicon carbide membrane
NASA Astrophysics Data System (ADS)
Diagne, Ndeye Fama
Flexural Plate Wave (FPW) devices fabricated from Silicon Carbide (SiC) membranes are presented here which exhibit electrical and mechanical characteristics in its transfer functions that makes it very useful as a low voltage probe device capable of functioning in small areas that are commonly inaccessible to ordinary devices. The low input impedance characteristic of this current driven device makes it possible for it to operate at very low voltages, thereby reducing the hazards for flammable or explosive areas to be probed. The Flexural Plate Wave (FPW) devices are of a family of gravimetric type sensors that permit direct measurements of the mass of the vibrating element. The primary objective was to study the suitability of Silicon Carbide (SiC) membranes as a replacement of Silicon Nitride (SiN) membrane in flexural plate wave devices developed by Sandia National Laboratories. Fabrication of the Flexural Plate Wave devices involves the overlaying a silicon wafer with membranes of 3C-SiC thin film upon which conducting meander lines are placed. The input excitation energy is in the form of an input current. The lines of current along the direction of the conducting Meander Lines Transducer (MLTs) and the applied perpendicular external magnetic field set up a mechanical wave perpendicular to both, exciting the membrane by means of a Lorentz force, which in turn sets up flexural waves that propagate along the thin membrane. The physical dimensions, the mass density, the tension in the membrane and the meander spacing are physical characteristics that determine resonance frequency of the Flexural Plate Wave (FPW) device. Of primary interest is the determination of the resonant frequency of the silicon carbide membrane as functions of the device physical characteristic parameters. The appropriate transduction scheme with Meander Line Transducers (IDTs) are used to excite the membrane. Equivalent circuit models characterizing the reflection response S11 (amplitude and phase) for a one-port Flexural PlateWave device and the transmission response S21 of a two-port device are used for the development of the equivalent mechanical characteristics.
Joghtaei, Mahmoud; Arab, Amir Massoud; Hashemi-Nasl, Hamed; Joghataei, Mohammad Taghi; Tokhi, Mohammad Osman
2015-03-01
Stiffness and viscosity represent passive resistances to joint motion related with the structural properties of the joint tissue and of the musculotendinous complex. Both parameters can be affected in patients with spinal cord injury (SCI). The purpose of this study was to measure passive knee stiffness and viscosity in patients with SCI with paraplegia and healthy subjects using Wartenberg pendulum test. Non-experimental, cross-sectional, case-control design. An outpatient physical therapy clinic, University of social welfare and Rehabilitation Science, Iran. A sample of convenience sample of 30 subjects participated in the study. Subjects were categorized into two groups: individuals with paraplegic SCI (n = 15, age: 34.60 ± 9.18 years) and 15 able-bodied individuals as control group (n = 15, age: 30.66 ± 11.13 years). Not applicable. Passive pendulum test of Wartenberg was used to measure passive viscous-elastic parameters of the knee (stiffness, viscosity) in all subjects. Statistical analysis (independent t-test) revealed significant difference in the joint stiffness between healthy subjects and those with paraplegic SCI (P = 0.01). However, no significant difference was found in the viscosity between two groups (P = 0.17). Except for first peak flexion angle, all other displacement kinematic parameters exhibited no statistically significant difference between normal subjects and subjects with SCI. Patients with SCI have significantly greater joint stiffness compared to able-bodied subjects.
Podgórski, Michał; Grzelak, Piotr; Kaczmarska, Magdalena; Polguj, Michał; Łukaszewski, Maciej; Stefańczyk, Ludomir
2018-02-01
Objective Arterial stiffening is an early marker of atherosclerosis that has a prognostic value for cardiovascular morbidity and mortality. Although many markers of arterial hardening have been proposed, the search is on for newer, more user-friendly and reliable surrogates. One such potential candidate has emerged from cardiology, the speckle-tracking technique. The aim of this study was to evaluate the feasibility of the two-dimensional speckle tracking for the evaluation of arterial wall stiffness in comparison with standard stiffness parameters. Methods Carotid ultrasound and applanation tonometry were performed in 188 patients with no cardiovascular risk factors. The following parameters were then evaluated: the intima-media complex thickness, distensibility coefficient, β-stiffness index, circumferential strain/strain rate, and pulse wave velocity and augmentation index. These variables were compared with each other and with patient age, and their reliability was assessed with Bland-Altman plots. Results Strain parameters derived from two-dimensional speckle tracking and intima-media complex thickness correlated better with age and pulse wave velocity than standard makers of arterial stiffness. Moreover, the reliability of these measurements was significantly higher than conventional surrogates. Conclusions Two-dimensional speckle tracing is a reliable method for the evaluation of arterial stiffness. Therefore, together with intima-media complex thickness measurement, it offers great potential in clinical practice as an early marker of atherosclerosis.
Siarampi, Eleni; Kontonasaki, Eleana; Andrikopoulos, Konstantinos S; Kantiranis, Nikolaos; Voyiatzis, George A; Zorba, Triantafillia; Paraskevopoulos, Konstantinos M; Koidis, Petros
2014-12-01
Dental zirconia restorations should present long-term clinical survival and be in service within the oral environment for many years. However, low temperature degradation could affect their mechanical properties and survival. The aim of this study was to investigate the effect of in vitro aging on the flexural strength of yttrium-stabilized (Y-TZP) zirconia ceramics for ceramic restorations. One hundred twenty bar-shaped specimens were prepared from two ceramics (ZENO Zr (WI) and IPS e.max(®) ZirCAD (IV)), and loaded until fracture according to ISO 6872. The specimens from each ceramic (nx=60) were divided in three groups (control, aged for 5h, aged for 10h). One-way ANOVA was used to assess statistically significant differences among flexural strength values (P<0.05). The variability of the flexural strength values was analyzed using the two-parameter Weibull distribution function, which was applied for the estimation of Weibull modulus (m) and characteristic strength (σ0). The crystalline phase polymorphs of the materials (tetragonal, t, and monoclinic, m, zirconia) were investigated by X-ray diffraction (XRD) analysis, Raman spectroscopy and Fourier transform infrared (FTIR) spectroscopy. A slight increase of the flexural strength after 5h, and a decrease after 10h of aging, was recorded for both ceramics, however statistically significant was for the WI group (P<0.05). Both ceramics presented a t→m phase transformation, with the m-phase increasing from 4 to 5% at 5h to around 15% after 10h. The significant reduction of the flexural strength after 10h of in vitro aging, suggests high fracture probability for one of the zirconia ceramics tested. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Ellis, Devon S.
Owing to their corrosion resistance and superior strength to weight ratio, there has been, over the past two decades, increased interest in the use of fiber-reinforced polymer (FRP) reinforcing bars in reinforced concrete structural members. The mechanical behavior of FRP reinforcement differs from that of steel reinforcement. For example, FRP reinforcement exhibit a linear stress-strain behavior until the bar ruptures and the strength, stiffness and bond properties of FRP reinforcement are affected more adversely by elevated temperatures. All structures are subject to the risk of damage by fire and fires continue to be a significant cause of damage to structures. Many structures do not collapse after being exposed to fire. The safety of the structure for any future use is dependent on the ability to accurately estimate the post-fire load capacity of the structure. Assuming that the changes, due to fire exposure, in the mechanical behavior of the GFRP reinforcing bar and concrete, and the bond between the reinforcing bar and the concrete are understood, an analytical procedure for estimating the post-fire strength of GFRP reinforced concrete flexural elements can be developed. This thesis investigates the changes in: a) tensile properties and bond of GFRP bars; and b) the flexural behavior of GFRP reinforced concrete beams flexural after being exposed to elevated temperatures up to 400°C and cooled to ambient temperature. To this end, twelve tensile tests, twelve pullout bond tests and ten four-point beam tests were performed. The data from the tests were used to formulate analytical procedures for evaluating the post-fire strength of GFRP reinforced concrete beams. The procedure produced conservative results when compared with the experimental data. In general, the residual tensile strength and modulus of elasticity of GFRP bars decrease as the exposure temperature increases. The loss in properties is however, smaller than that observed by other researchers when similar bars were tested while hot. The residual bond strength was also found to decrease with increase in exposure temperature. Residual bond mechanism and flexural behavior were found to be influenced, in complex ways, by the exposure to elevated temperatures. Additionally, an apparent "yielding plateau" and an apparent increase in bar ductility was observed in the post-heat behavior of some of the tensile specimens. This points to a potential for heat treatment of FRP bars to achieve higher ductility.
Flexural wave attenuation in a sandwich beam with viscoelastic periodic cores
NASA Astrophysics Data System (ADS)
Guo, Zhiwei; Sheng, Meiping; Pan, Jie
2017-07-01
The flexural-wave attenuation performance of traditional constraint-layer damping in a sandwich beam is improved by using periodic constrained-layer damping (PCLD), where the monolithic viscoelastic core is replaced with two periodically alternating viscoelastic cores. Closed-form solutions of the wave propagation constants of the infinite periodic sandwich beam and the forced response of the corresponding finite sandwich structure are theoretically derived, providing computational support on the analysis of attenuation characteristics. In a sandwich beam with PCLD, the flexural waves can be attenuated by both Bragg scattering effect and damping effect, where the attenuation level is mainly dominated by Bragg scattering in the band-gaps and by damping in the pass-bands. Affected by these two effects, when the parameters of periodic cores are properly selected, a sandwich beam with PCLD can effectively reduce vibrations of much lower frequencies than that with traditional constrained-layer damping. The effects of the parameters of viscoelastic periodic cores on band-gap properties are also discussed, showing that the average attenuation in the desired frequency band can be maximized by tuning the length ratio and core thickness to proper values. The research in this paper could possibly provide useful information for the researches and engineers to design damping structures.
Leg stiffness and expertise in men jumping.
Laffaye, Guillaume; Bardy, Benoît G; Durey, Alain
2005-04-01
The aim of the present study is to investigate: a) the leg spring behavior in the one-leg vertical jump, b) the contribution of impulse parameters to this behavior, and c) the effect of jumping expertise on leg stiffness. Four categories of experts (handball, basketball, volleyball players, and Fosbury athletes), as well as novice subjects performed a run-and-jump test to touch a ball with the head. Five experimental conditions were tested from 55 to 95% of the maximum jump height. Kinematic and kinetic data were collected using six cameras and a force plate. The mechanical behavior of the musculoskeleton component of the human body can be modeled as a simple mass-spring system, from which leg stiffness values can be extracted to better understand energy transfer during running or jumping. The results indicate that leg stiffness (mean value of 11.5 kN.m) decreased with jumping height. Leg shortening at takeoff also increased with jumping height, whereas contact time decreased (-18%). No difference was found between experts and novices for leg stiffness. However, a principal components analysis (PCA) indicated the contribution of two main factors to the performance. The first factor emerged out of vertical force, stiffness, and duration of impulse. The second factor included leg shortening and jumping height. Differences between experts and novices were observed in terms of the contribution of leg stiffness to jump height, and more importantly, clear differences existed between experts in jumping parameters. The analysis performed on the sport categories indeed revealed different jumping profiles, characterized by specific, sport-related impulse parameters.
The contribution of quasi-joint stiffness of the ankle joint to gait in patients with hemiparesis.
Sekiguchi, Yusuke; Muraki, Takayuki; Kuramatsu, Yuko; Furusawa, Yoshihito; Izumi, Shin-Ichi
2012-06-01
The role of ankle joint stiffness during gait in patients with hemiparesis has not been clarified. The purpose of this study was to determine the contribution of quasi-joint stiffness of the ankle joint to spatiotemporal and kinetic parameters regarding gait in patients with hemiparesis due to brain tumor or stroke and healthy individuals. Spatiotemporal and kinetic parameters regarding gait in twelve patients with hemiparesis due to brain tumor or stroke and nine healthy individuals were measured with a 3-dimensional motion analysis system. Quasi-joint stiffness was calculated from the slope of the linear regression of the moment-angle curve of the ankle joint during the second rocker. There was no significant difference in quasi-joint stiffness among both sides of patients and the right side of controls. Quasi-joint stiffness on the paretic side of patients with hemiparesis positively correlated with maximal ankle power (r=0.73, P<0.01) and gait speed (r=0.66, P<0.05). In contrast, quasi-joint stiffness in controls negatively correlated with maximal ankle power (r=-0.73, P<0.05) and gait speed (r=-0.76, P<0.05). Our findings suggested that ankle power during gait might be generated by increasing quasi-joint stiffness in patients with hemiparesis. In contrast, healthy individuals might decrease quasi-joint stiffness to avoid deceleration of forward tilt of the tibia. Our findings might be useful for selecting treatment for increased ankle stiffness due to contracture and spasticity in patients with hemiparesis. Copyright © 2011 Elsevier Ltd. All rights reserved.
Parametric excitation of tire-wheel assemblies by a stiffness non-uniformity
NASA Astrophysics Data System (ADS)
Stutts, D. S.; Krousgrill, C. M.; Soedel, W.
1995-01-01
A simple model of the effect of a concentrated radial stiffness non-uniformity in a passenger car tire is presented. The model treats the tread band of the tire as a rigid ring supported on a viscoelastic foundation. The distributed radial stiffness is lumped into equivalent horizontal (fore-and-aft) and vertical stiffnesses. The concentrated radial stiffness non-uniformity is modeled by treating the tread band as fixed, and the stiffness non-uniformity as rotating around it at the nominal angular velocity of the wheel. Due to loading, the center of mass of the tread band ring model is displaced upward with respect to the wheel spindle and, therefore, the rotating stiffness non-uniformity is alternately compressed and stretched through one complete rotation. This stretching and compressing of the stiffness non-uniformity results in force transmission to the wheel spindle at twice the nominal angular velocity in frequency, and therefore, would excite a given resonance at one-half the nominal angular wheel velocity that a mass unbalance would. The forcing produced by the stiffness non-uniformity is parametric in nature, thus creating the possibility of parametric resonance. The basic theory of the parametric resonance is explained, and a parameter study using derived lumped parameters based on a typical passenger car tire is performed. This study revealed that parametric resonance in passenger car tires, although possible, is unlikely at normal highway speeds as predicted by this model unless the tire is partially deflated.
FSW of Aluminum Tailor Welded Blanks across Machine Platforms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hovanski, Yuri; Upadhyay, Piyush; Carlson, Blair
2015-02-16
Development and characterization of friction stir welded aluminum tailor welded blanks was successfully carried out on three separate machine platforms. Each was a commercially available, gantry style, multi-axis machine designed specifically for friction stir welding. Weld parameters were developed to support high volume production of dissimilar thickness aluminum tailor welded blanks at speeds of 3 m/min and greater. Parameters originally developed on an ultra-high stiffness servo driven machine where first transferred to a high stiffness servo-hydraulic friction stir welding machine, and subsequently transferred to a purpose built machine designed to accommodate thin sheet aluminum welding. The inherent beam stiffness, bearingmore » compliance, and control system for each machine were distinctly unique, which posed specific challenges in transferring welding parameters across machine platforms. This work documents the challenges imposed by successfully transferring weld parameters from machine to machine, produced from different manufacturers and with unique control systems and interfaces.« less
Application of Novel Lateral Tire Force Sensors to Vehicle Parameter Estimation of Electric Vehicles
Nam, Kanghyun
2015-01-01
This article presents methods for estimating lateral vehicle velocity and tire cornering stiffness, which are key parameters in vehicle dynamics control, using lateral tire force measurements. Lateral tire forces acting on each tire are directly measured by load-sensing hub bearings that were invented and further developed by NSK Ltd. For estimating the lateral vehicle velocity, tire force models considering lateral load transfer effects are used, and a recursive least square algorithm is adapted to identify the lateral vehicle velocity as an unknown parameter. Using the estimated lateral vehicle velocity, tire cornering stiffness, which is an important tire parameter dominating the vehicle’s cornering responses, is estimated. For the practical implementation, the cornering stiffness estimation algorithm based on a simple bicycle model is developed and discussed. Finally, proposed estimation algorithms were evaluated using experimental test data. PMID:26569246
NASA Astrophysics Data System (ADS)
Sun, Xiuting; Jing, Xingjian
2016-12-01
This study investigates theoretically and experimentally a vibration isolator constructed by an n-layer Scissor-Like Structure (SLS), focusing on the analysis and design of nonlinear stiffness and damping characteristics for advantageous isolation performance in both orthogonal directions. With the mathematical modeling, the influence incurred by different structural parameters on system isolation performance is studied. It is shown that, (a) nonlinear high-static-low-dynamic stiffness and damping characteristics can be seen such that the system can achieve good isolation performance in both directions, (b) an anti-resonance frequency band exists due to the coupling effect between the linear and nonlinear stiffness in the two orthogonal directions within the structure, and (c) all these performances are designable with several structural parameters. The advantages of the proposed system are shown through comparisons with an existing quasi-zero-stiffness vibration isolator (QZS-VI) and a traditional mass-spring-damper vibration isolator (MSD-VI), and further validated by experimental results.
Quantifying Effects of Voids in Woven Ceramic Matrix Composites
NASA Technical Reports Server (NTRS)
Goldsmith, Marlana B.; Sankar, Bhavani V.; Haftka, Raphael T.; Goldberg, Robert K.
2013-01-01
Randomness in woven ceramic matrix composite architecture has been found to cause large variability in stiffness and strength. The inherent voids are an aspect of the architecture that may cause a significant portion of the variability. A study is undertaken to investigate the effects of many voids of random sizes and distributions. Response surface approximations were formulated based on void parameters such as area and length fractions to provide an estimate of the effective stiffness. Obtaining quantitative relationships between the properties of the voids and their effects on stiffness of ceramic matrix composites are of ultimate interest, but the exploratory study presented here starts by first modeling the effects of voids on an isotropic material. Several cases with varying void parameters were modeled which resulted in a large amount of variability of the transverse stiffness and out-of-plane shear stiffness. An investigation into a physical explanation for the stiffness degradation led to the observation that the voids need to be treated as an entity that reduces load bearing capabilities in a space larger than what the void directly occupies through a corrected length fraction or area fraction. This provides explanation as to why void volume fraction is not the only important factor to consider when computing loss of stiffness.
Joghtaei, Mahmoud; Arab, Amir Massoud; Hashemi-Nasl, Hamed; Joghataei, Mohammad Taghi; Tokhi, Mohammad Osman
2015-01-01
Objective Stiffness and viscosity represent passive resistances to joint motion related with the structural properties of the joint tissue and of the musculotendinous complex. Both parameters can be affected in patients with spinal cord injury (SCI). The purpose of this study was to measure passive knee stiffness and viscosity in patients with SCI with paraplegia and healthy subjects using Wartenberg pendulum test. Design Non-experimental, cross-sectional, case–control design. Setting An outpatient physical therapy clinic, University of social welfare and Rehabilitation Science, Iran. Patients A sample of convenience sample of 30 subjects participated in the study. Subjects were categorized into two groups: individuals with paraplegic SCI (n = 15, age: 34.60 ± 9.18 years) and 15 able-bodied individuals as control group (n = 15, age: 30.66 ± 11.13 years). Interventions Not applicable. Main measures Passive pendulum test of Wartenberg was used to measure passive viscous-elastic parameters of the knee (stiffness, viscosity) in all subjects. Results Statistical analysis (independent t-test) revealed significant difference in the joint stiffness between healthy subjects and those with paraplegic SCI (P = 0.01). However, no significant difference was found in the viscosity between two groups (P = 0.17). Except for first peak flexion angle, all other displacement kinematic parameters exhibited no statistically significant difference between normal subjects and subjects with SCI. Conclusions Patients with SCI have significantly greater joint stiffness compared to able-bodied subjects. PMID:25437824
NASA Astrophysics Data System (ADS)
Lu, Ch. Zh.; Li, Jingyuan; Zhou, Bangyang; Li, Shuang
2017-09-01
The static stiffness and dynamic damping properties of a metallic rubber material (MR) were investigated, which exhibited a nonlinear deformation behavior. Its static stiffness is analyzed and discussed. The effects of structural parameters of MR and experimental conditions on its shock absorption capacity were examined by dynamic tests. Results revealed excellent elastic and damping properties of the material. Its stiffness increased with density, but decreased with thickness. The damping property of MR varied with its density, thickness, loading frequency, and amplitude.
Electrical and Mechanical Properties of 3D-Printed Graphene-Reinforced Epoxy
NASA Astrophysics Data System (ADS)
Compton, Brett G.; Hmeidat, Nadim S.; Pack, Robert C.; Heres, Maximilian F.; Sangoro, Joshua R.
2018-03-01
Recent developments in additive manufacturing have demonstrated the potential for thermoset polymer feedstock materials to achieve high strength, stiffness, and functionality through incorporation of structural and functional filler materials. In this work, graphene was investigated as a potential filler material to provide rheological properties necessary for direct-write three-dimensional (3D) printing and electrostatic discharge properties to the printed component. The rheological properties of epoxy/graphene mixtures were characterized, and printable epoxy/graphene inks formulated. Sheet resistance values for printed epoxy/graphene composites ranged from 0.67 × 102 Ω/sq to 8.2 × 103 Ω/sq. The flexural strength of printed epoxy/graphene composites was comparable to that of cast neat epoxy ( 80 MPa), suggesting great potential for these new materials in multifunctional 3D-printed devices.
Fabrication and testing of non-graphitic superhybrid composites
NASA Technical Reports Server (NTRS)
Lark, R. F.; Sinclair, J. H.; Chamis, C. C.
1979-01-01
A study was conducted to determine the fabrication feasibility and the mechanical properties of adhesively-bonded boron aluminum/titanium and non-graphitic fiber/epoxy resin superhybrid (NGSH) composite laminates for potential aerospace applications. The major driver for this study was the elimination of a potential graphite fiber release problem in the event of a fire. The results of the study show that non-graphitic fibers, such as S-glass and Kevlar 49, may be substituted for the graphite fibers used in superhybrid (SH) composites for some applications. As is to be expected, however, the non-graphitic superhybrids have lower stiffness properties than the graphitic superhybrids. In-plane and flexural moduli of the laminates studied in this program can be predicted reasonably well using linear laminate theory while nonlinear laminate theory is required for strength predictions.
Influence of Torsion Effect on the Mechanical Characteristics of Reinforced Concrete Column
NASA Astrophysics Data System (ADS)
Wang, Debin; Fan, Guoxi
2017-11-01
The purpose of this paper is to study the effect of torsional effect and loading rate on the flexural capacity of RC members. Based on the fiber model of finite element software ABAQUS, a model has been established with the consideration of the strain rate sensitivity of steel and concrete. The model is used to reflect the influence of the rotational component of ground motion by applying the initial angular displacement. The mechanical properties of RC columns under monotonic loads are simulated. The simulation results show that there has been a decrease in the carrying capacity and initial stiffness of RC columns for high initial torsion angle. With the increase of initial torsion angle, the influence of loading rate on RC columns gradually increases.
Distribution of flexural deflection in the worldwide outer rise area
NASA Astrophysics Data System (ADS)
Lin, Zi-Jun; Lin, Jing-Yi; Lin, Yi-Chin; Chin, Shao-Jinn; Chen, Yen-Fu
2015-04-01
The outer rise on the fringe of a subduction system is caused by an accreted load on the flexed oceanic lithosphere. The magnitude of the deflection is usually linked to the stress state beard by the oceanic plate. In a coupled subduction zone, the stress is abundantly accumulated across the plate boundary which should affect the flexural properties of the subducted plate. Thus, the variation of the outer rise in shape may reflect the seismogenic characteristics of the subduction system. In this study, we intent to find the correlation between the flexure deflection (Wb) of the outer rise and the subduction zone properties by comparing several slab parameters and the Wb distribution. The estimation of Wb is performed based on the available bathymetry data and the statistic analysis of earthquakes is from the global ISC earthquake catalog for the period of 1900-2015. Our result shows a progressive change of Wb in space, suggesting a robust calculation. The average Wb of worldwise subduction system spreads from 348 to 682 m. No visible distinction in the ranging of Wb was observed for different subduction zones. However, in a weak coupling subduction system, the standard variation of Wb has generally larger value. Relatively large Wb generally occurs in the center of the trench system, whereas small Wb for the two ends of trench. The comparison of Wb and several slab parameters shows that the Wb may be correlated with the maximal magnitude and the number of earthquakes. Otherwise, no clear relationship with other parameters can be obtained.
Parylene-coated ionic liquid-carbon nanotube actuators for user-safe haptic devices.
Bubak, Grzegorz; Gendron, David; Ceseracciu, Luca; Ansaldo, Alberto; Ricci, Davide
2015-07-22
Simple fabrication, high power-to-weight and power-to-volume ratios, and the ability to operate in open air at low voltage make the ionic electroactive polymer actuators highly attractive for haptic applications. Whenever a direct tactile stimulation of the skin is involved, electrical and chemical insulation as well as a long-term stability of the actuator are required. Because of its inherent physicochemical properties such as high dielectric strength, resistance to solvents, and biological inactivity, Parylene C meets the requirements for making biocompatible actuators. We have studied the displacement and the generated force of Parylene-coated carbon nanotube actuators as well as the encapsulation quality. A 2 μm coating creates an effective electrical insulation of the actuators without altering the blocking force at frequencies from 50 mHz to 1 Hz. Moreover, the generated strain is preserved at higher frequencies (from 0.5 to 5 Hz). We employed a simple mechanical model to explain the relation between the key parameters-flexural stiffness, displacement, and force-for uncoated and coated actuators. In addition, we demonstrated that our Parylene-coated actuators are not damaged by rinsing in liquid media such as 2-propanol or water. In conclusion, our results indicate that Parylene C encapsulated actuators are safe to touch and can be used in contact with human skin and in biomedical applications in direct contact with tissues and physiological fluids.
Effect of stacking sequence on the coefficients of mutual influence of composite laminates
NASA Astrophysics Data System (ADS)
Dupir (Hudișteanu, I.; Țăranu, N.; Axinte, A.
2016-11-01
Fiber reinforced polymeric (FRP) composites are nowadays widely used in engineering applications due to their outstanding features, such as high specific strength and specific stiffness as well as good corrosion resistance. A major advantage of fibrous polymeric composites is that their anisotropy can be controlled through suitable choice of the influencing parameters. The unidirectional fiber reinforced composites provide much higher longitudinal mechanical properties compared to the transverse ones. Therefore, composite laminates are formed by stacking two or more laminas, with different fiber orientations, as to respond to complex states of stresses. These laminates experience the effect of axial-shear coupling, which is caused by applying normal or shear stresses, implying shear or normal strains, respectively. The normal-shear coupling is expressed by the coefficients of mutual influence. They are engineering constants of primary interest for composite laminates, since the mismatch of the material properties between adjacent layers can produce interlaminar stresses and/or plies delamination. The paper presents the variation of the in-plane and flexural coefficients of mutual influence for three types of multi-layered composites, with different stacking sequences. The results are obtained using the Classical Lamination Theory (CLT) and are illustrated graphically in terms of fiber orientations, for asymmetric, antisymmetric and symmetric laminates. Conclusions are formulated on the variation of these coefficients, caused by the stacking sequence.
Casado Cerrada, Jesús; Parra Caballero, Pedro; Vega Piris, Lorena; Suárez Fernández, Carmen
2013-10-05
Vitamin D deficiency and parathyroid hormone (PTH) are associated with an increased cardiovascular risk and arterial stiffness. The aim of our study is to compare the cardiovascular risk in subjects with low vitamin D, attending to the PTH concentration, as well as evaluating the response after administration of vitamin D. Prospective study of patients with a concentration of 25(OH)-vitamin D below 30nmol/l. We evaluated vascular risk parameters as blood pressure, arterial stiffness, lipid profile and glucose metabolism. Patients received vitamin D supplements for 3 months, after which the previous parameters were reassessed. A total of 32 patients were included. Those with PTH over 65pg/ml were older, had worse renal function, higher systolic blood pressure, pulse pressure and arterial stiffness. Treatment with vitamin D showed a statistically significant trend to lower blood pressure and pulse wave velocity. The increase in PTH in patients with low vitamin D involves poor control of blood pressure and increased vascular stiffness. Vitamin D replacement shows a tendency to reduce these parameters. Copyright © 2012 Elsevier España, S.L. All rights reserved.
Hasegawa, Kazuhiro; Kitahara, Ko; Hara, Toshiaki; Takano, Ko; Shimoda, Haruka; Homma, Takao
2008-03-01
In vivo quantitative measurement of lumbar segmental stability has not been established. The authors developed a new measurement system to determine intraoperative lumbar stability. The objective of this study was to clarify the biomechanical properties of degenerative lumbar segments by using the new method. Twenty-two patients with a degenerative symptomatic segment were studied and their measurements compared with those obtained in normal or asymptomatic degenerative segments (Normal group). The measurement system produces cyclic flexion-extension through spinous process holders by using a computer-controlled motion generator with all ligamentous structures intact. The following biomechanical parameters were determined: stiffness, absorption energy (AE), and neutral zone (NZ). Discs with degeneration were divided into 2 groups based on magnetic resonance imaging grading: degeneration without collapse (Collapse[-]) and degeneration with collapse (Collapse[+]). Biomechanical parameters were compared among the groups. Relationships among the biomechanical parameters and age, diagnosis, or radiographic parameters were analyzed. The mean stiffness value in the Normal group was significantly greater than that in Collapse(-) or Collapse(+) group. There was no significant difference in the average AE value among the Normal, Collapse(-), and Collapse(+) groups. The NZ in the Collapse(-) was significantly higher than in the Normal or Collapse(+) groups. Stiffness was negatively and NZ was positively correlated with age. Stiffness demonstrated a significant negative and NZ a significant positive relationship with disc height, however. There were no significant differences in stiffness between spines in the Collapse(-) and Collapse(+) groups. The values of a more sensitive parameter, NZ, were higher in Collapse(-) than in Collapse(+) groups, demonstrating that degenerative segments with preserved disc height have a latent instability compared to segments with collapsed discs.
Nondimensional parameter for conformal grinding: combining machine and process parameters
NASA Astrophysics Data System (ADS)
Funkenbusch, Paul D.; Takahashi, Toshio; Gracewski, Sheryl M.; Ruckman, Jeffrey L.
1999-11-01
Conformal grinding of optical materials with CNC (Computer Numerical Control) machining equipment can be used to achieve precise control over complex part configurations. However complications can arise due to the need to fabricate complex geometrical shapes at reasonable production rates. For example high machine stiffness is essential, but the need to grind 'inside' small or highly concave surfaces may require use of tooling with less than ideal stiffness characteristics. If grinding generates loads sufficient for significant tool deflection, the programmed removal depth will not be achieved. Moreover since grinding load is a function of the volumetric removal rate the amount of load deflection can vary with location on the part, potentially producing complex figure errors. In addition to machine/tool stiffness and removal rate, load generation is a function of the process parameters. For example by reducing the feed rate of the tool into the part, both the load and resultant deflection/removal error can be decreased. However this must be balanced against the need for part through put. In this paper a simple model which permits combination of machine stiffness and process parameters into a single non-dimensional parameter is adapted for a conformal grinding geometry. Errors in removal can be minimized by maintaining this parameter above a critical value. Moreover, since the value of this parameter depends on the local part geometry, it can be used to optimize process settings during grinding. For example it may be used to guide adjustment of the feed rate as a function of location on the part to eliminate figure errors while minimizing the total grinding time required.
Energy storage in structural composites by introducing CNT fiber/polymer electrolyte interleaves.
Senokos, Evgeny; Ou, Yunfu; Torres, Juan Jose; Sket, Federico; González, Carlos; Marcilla, Rebeca; Vilatela, Juan J
2018-02-21
This work presents a method to produce structural composites capable of energy storage. They are produced by integrating thin sandwich structures of CNT fiber veils and an ionic liquid-based polymer electrolyte between carbon fiber plies, followed by infusion and curing of an epoxy resin. The resulting structure behaves simultaneously as an electric double-layer capacitor and a structural composite, with flexural modulus of 60 GPa and flexural strength of 153 MPa, combined with 88 mF/g of specific capacitance and the highest power (30 W/kg) and energy (37.5 mWh/kg) densities reported so far for structural supercapacitors. In-situ electrochemical measurements during 4-point bending show that electrochemical performance is retained up to fracture, with minor changes in equivalent series resistance for interleaves under compressive stress. En route to improving interlaminar properties we produce grid-shaped interleaves that enable mechanical interconnection of plies by the stiff epoxy. Synchrotron 3D X-ray tomography analysis of the resulting hierarchical structure confirms the formation of interlaminar epoxy joints. The manuscript discusses encapsulation role of epoxy, demonstrated by charge-discharge measurements of composites immersed in water, a deleterious agent for ionic liquids. Finally, we show different architectures free of current collector and electrical insulators, in which both CNT fiber and CF act as active electrodes.
Mancia, Claire; Loustaud-Ratti, Véronique; Carrier, Paul; Naudet, Florian; Bellissant, Eric; Labrousse, François; Pichon, Nicolas
2015-08-01
One of the main selection criteria of the quality of a liver graft is the degree of steatosis, which will determine the success of the transplantation. The aim of this study was to evaluate the ability of FibroScan and its related methods Controlled Attenuation Parameter and Liver Stiffness to assess objectively steatosis and fibrosis in livers from brain-dead donors to be potentially used for transplantation. Over a period of 10 months, 23 consecutive brain dead donors screened for liver procurement underwent a FibroScan and a liver biopsy. The different predictive models of liver retrievability using liver biopsy as the gold standard have led to the following area under receiver operating characteristic curve: 76.6% (95% confidence intervals [95% CIs], 48.2%-100%) when based solely on controlled attenuation parameter, 75.0% (95% CIs, 34.3%-100%) when based solely on liver stiffness, and 96.7% (95% CIs, 88.7%-100%) when based on combined indices. Our study suggests that a preoperative selection of brain-dead donors based on a combination of both Controlled Attenuation Parameter and Liver Stiffness obtained with FibroScan could result in a good preoperative prediction of the histological status and degree of steatosis of a potential liver graft.
Sobhani Tehrani, Ehsan; Jalaleddini, Kian; Kearney, Robert E
2013-01-01
This paper describes a novel model structure and identification method for the time-varying, intrinsic stiffness of human ankle joint during imposed walking (IW) movements. The model structure is based on the superposition of a large signal, linear, time-invariant (LTI) model and a small signal linear-parameter varying (LPV) model. The methodology is based on a two-step algorithm; the LTI model is first estimated using data from an unperturbed IW trial. Then, the LPV model is identified using data from a perturbed IW trial with the output predictions of the LTI model removed from the measured torque. Experimental results demonstrate that the method accurately tracks the continuous-time variation of normal ankle intrinsic stiffness when the joint position changes during the IW movement. Intrinsic stiffness gain decreases from full plantarflexion to near the mid-point of plantarflexion and then increases substantially as the ankle is dosriflexed.
Near-Field Acoustical Imaging using Lateral Bending Mode of Atomic Force Microscope Cantilevers
NASA Astrophysics Data System (ADS)
Caron, A.; Rabe, U.; Rödel, J.; Arnold, W.
Scanning probe microscopy techniques enable one to investigate surface properties such as contact stiffness and friction between the probe tip and a sample with nm resolution. So far the bending and the torsional eigenmodes of an atomic force microscope cantilever have been used to image variations of elasticity and shear elasticity, respectively. Such images are near-field images with the resolution given by the contact radius typically between 10 nm and 50 nm. We show that the flexural modes of a cantilever oscillating in the width direction and parallel to the sample surface can also be used for imaging. Additional to the dominant in-plane component of the oscillation, the lateral modes exhibit a vertical component as well, provided there is an asymmetry in the cross-section of the cantilever or in its suspension. The out-of-plane deflection renders the lateral modes detectable by the optical position sensors used in atomic force microscopes. We studied cracks which were generated by Vickers indents, in submicro- and nanocrystalline ZrO2. Images of the lateral contact stiffness were obtained by vibrating the cantilever close to a contact-resonance frequency. A change in contact stiffness causes a shift of the resonant frequency and hence a change of the cantilever vibration amplitude. The lateral contact-stiffness images close to the crack faces display a contrast that we attribute to altered elastic properties indicating a process zone. This could be caused by a stress-induced phase transformation during crack propagation. Using the contact mode of an atomic force microscope, we measured the crack-opening displacement as a function of distance from the crack tip, and we determined the crack-tip toughness Ktip. Furthermore, K1c was inferred from the length of radial cracks of Vickers indents that were measured using classical scanning acoustic microscopy
Danquechin Dorval, Antoine; Meredieu, Céline; Danjon, Frédéric
2016-07-25
Storms can cause huge damage to European forests. Even pole-stage trees with 80-cm rooting depth can topple. Therefore, good anchorage is needed for trees to survive and grow up from an early age. We hypothesized that root architecture is a predominant factor determining anchorage failure caused by strong winds. We sampled 48 seeded or planted Pinus pinaster trees of similar aerial size from four stands damaged by a major storm 3 years before. The trees were gathered into three classes: undamaged, leaning and heavily toppled. After uprooting and 3D digitizing of their full root architectures, we computed the mechanical characteristics of the main components of the root system from our morphological measurements. Variability in root architecture was quite large. A large main taproot, either short and thick or long and thin, and guyed by a large volume of deep roots, was the major component that prevented stem leaning. Greater shallow root flexural stiffness mainly at the end of the zone of rapid taper on the windward side also prevented leaning. Toppling in less than 90-cm-deep soil was avoided in trees with a stocky taproots or with a very big leeward shallow root. Toppled trees also had a lower relative root biomass - stump excluded - than straight trees. It was mainly the flexural stiffness of the central part of the root system that secured anchorage, preventing a weak displacement of the stump. The distal part of the longest taproot and attached deep roots may be the only parts of the root system contributing to anchorage through their maximum tensile load. Several designs provided good anchorage, depending partly on available soil depth. Pole-stage trees are in-between the juvenile phase when they fail by toppling and the mature phase when they fail by uprooting. © The Author 2016. Published by Oxford University Press on behalf of the Annals of Botany Company. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Parameter identification and optimization of slide guide joint of CNC machine tools
NASA Astrophysics Data System (ADS)
Zhou, S.; Sun, B. B.
2017-11-01
The joint surface has an important influence on the performance of CNC machine tools. In order to identify the dynamic parameters of slide guide joint, the parametric finite element model of the joint is established and optimum design method is used based on the finite element simulation and modal test. Then the mode that has the most influence on the dynamics of slip joint is found through harmonic response analysis. Take the frequency of this mode as objective, the sensitivity analysis of the stiffness of each joint surface is carried out using Latin Hypercube Sampling and Monte Carlo Simulation. The result shows that the vertical stiffness of slip joint surface constituted by the bed and the slide plate has the most obvious influence on the structure. Therefore, this stiffness is taken as the optimization variable and the optimal value is obtained through studying the relationship between structural dynamic performance and stiffness. Take the stiffness values before and after optimization into the FEM of machine tool, and it is found that the dynamic performance of the machine tool is improved.
Endes, Simon; Caviezel, Seraina; Schaffner, Emmanuel; Dratva, Julia; Schindler, Christian; Künzli, Nino; Bachler, Martin; Wassertheurer, Siegfried; Probst-Hensch, Nicole; Schmidt-Trucksäss, Arno
There is a lack of evidence concerning associations between novel parameters of arterial stiffness as cardiovascular risk markers and traditional structural and functional vascular biomarkers in a population-based Caucasian cohort. We examined these associations in the second follow-up of the Swiss Cohort Study on Air Pollution and Lung and Heart Diseases in Adults (SAPALDIA 3). Arterial stiffness was measured oscillometrically by pulse wave analysis to derive the cardio-ankle vascular index (CAVI), brachial-ankle (baPWV) and aortic pulse wave velocity (aPWV), and amplitude of the forward and backward wave. Carotid ultrasonography was used to measure carotid intima-media thickness (cIMT) and carotid lumen diameter (LD), and to derive a distensibility coefficient (DC). We used multivariable linear regression models adjusted for several potential confounders for 2,733 people aged 50-81 years. CAVI, aPWV and the amplitude of the forward and backward wave were significant predictors of cIMT (p < 0.001). All parameters were significantly associated with LD (p < 0.001), with aPWV and the amplitude of the forward wave explaining the highest proportion of variance (2%). Only CAVI and baPWV were significant predictors of DC (p < 0.001), explaining more than 0.3% of the DC variance. We demonstrated that novel non-invasive oscillometric arterial stiffness parameters are differentially associated with specific established structural and functional local stiffness parameters. Longitudinal studies are needed to follow-up on these cross-sectional findings and to evaluate their relevance for clinical phenotypes.
Afsar, Baris; Elsurer, Rengin; Soypacaci, Zeki; Kanbay, Mehmet
2016-02-01
Although anthropometric measurements are related with clinical outcomes; these relationships are not universal and differ in some disease states such as in chronic kidney disease (CKD). The current study was aimed to analyze the relationship between height, weight and BMI with hemodynamic and arterial stiffness parameters both in normal and CKD patients separately. This cross-sectional study included 381 patients with (N 226) and without CKD (N 155) with hypertension. Routine laboratory and 24-h urine collection were performed. Augmentation index (Aix) which is the ratio of augmentation pressure to pulse pressure was calculated from the blood pressure waveform after adjusted heart rate at 75 [Aix@75 (%)]. Pulse wave velocity (PWV) is a simple measure of the time taken by the pressure wave to travel over a specific distance. Both [Aix@75 (%)] and PWV which are measures of arterial stiffness were measured by validated oscillometric methods using mobil-O-Graph device. In patients without CKD, height is inversely correlated with [Aix@75 (%)]. Additionally, weight and BMI were positively associated with PWV in multivariate analysis. However, in patients with CKD, weight and BMI were inversely and independently related with PWV. In CKD patients, as weight and BMI increased stiffness parameters such as Aix@75 (%) and PWV decreased. While BMI and weight are positively associated with arterial stiffness in normal patients, this association is negative in patients with CKD. In conclusion, height, weight and BMI relationship with hemodynamic and arterial stiffness parameters differs in patients with and without CKD.
Relationship between glycaemic levels and arterial stiffness in non-diabetic adults.
Cavero-Redondo, Iván; Martínez-Vizcaíno, Vicente; Álvarez-Bueno, Celia; Recio-Rodríguez, José Ignacio; Gómez-Marcos, Manuel Ángel; García-Ortiz, Luis
2018-01-23
To examine, in a non-diabetic population, whether the association between arterial stiffness and glycaemic levels depends on the test used as a glycaemic indicator, fasting plasma glucose (FPG) or glycated haemoglobin A1c (HbA1c). A cross-sectional analysis of a 220 non-diabetic subsample from the EVIDENT II study in which FPG, HbA1c and arterial stiffness-related parameters (pulse wave velocity, radial and central augmentation index, and central pulse pressure) were determined. Mean differences in arterial stiffness-related parameters by HbA1c and FPG tertiles were tested using analysis of covariance. All means of arterial stiffness-related parameters increased by HbA1c tertiles, although mean differences were only statistically significant in pulse wave velocity (p ≤.001), even after controlling for potential confounders (HbA1c <5.30% = 6.88 m/s; HbA1c 5.30%-5.59% = 7.06 m/s; and HbA1c ≥5.60% = 8.16 m/s, p =.004). Conversely, mean differences in pulse wave velocity by FPG tertiles did not reach statistically significant differences after controlling for potential confounders (FPG 4.44 mmol/l = 7.18 m/s; FPG 4.44 mmol/l-4.87 mmol/l = 7.26 m/s; and FPG ≥4.88 mmol/l = 7.93 m/s, p =.066). Glucose levels in a non-diabetic population were associated with arterial stiffness but better when levels were determined using HbA1c. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.
AXAF SIM focus mechanism study
NASA Technical Reports Server (NTRS)
Tananbaum, H. D.; Whitbeck, E.
1994-01-01
The design requirements and initial design concept for the AXAF-I Science Instrument Module (SIM) were reviewed at Ball on September 29, 1993. The concept design SIM focus mechanism utilizes a planetary gearset, with redundant motors, to drive a large ring (called 'main housing bearing') via a spur gearset. This large drive ring actuates three tangent bar links (called 'push rods'), which in turn actuate three levers (called 'pin levers'). Each of the three pin levers rotates an 'eccentric pin,' which in turn moves the base of a bipod flexure in both the radial (normal to optical axis) and axial (focus along optical axis) directions. Three bipod flexures are employed, equally spaced at 120 degrees apart, the base of each being translated in the two directions as described above. A focus adjustment is made by rotating the drive ring, which drives the push rods and therefore the pin levers, which in turn rotate the eccentric pins, finally imparting the two motions to the base of each of the bipod flexures. The axial translation (focus adjustment) of the focused structure is the sum of the direct axial motion plus axial motion which comes from uniformly squeezing the three bipod bases radially inward. SAO documented the following concerns regarding the focus mechanism in memo WAP-FY94-001, dated October 7, 1993: (1) The focus adjustment depends, in large part, on the structural properties (stiffnesses and end fixities) of the bipod flexures, push rods, pin levers and eccentric pins. If these properties are not matched very well, then lateral translations as well as unwanted rotations of the focussed structure will accompany focus motion. In addition, the stackup of linkage tolerances and any nonuniform wear in the linkages will result in the same unwanted motions. Thermal gradients will also affect these motions. At the review Ball did not present supporting analyses to support their choice of this design concept. (2) The proposed 'primary' method of measuring focus is by counting motor steps. The 'backup' method is by a pot mounted on the drive ring. Neither method provides for a direct measurement of the quantity desired (focus position). This is of concern because of the long and indirect relationship between focus and the sensed quantity (drive ring rotation). There are three sinusoidal relationships and structural stiffness in the path, and the resulting calibration is likely to be highly nonlinear. These methods would require an accurate ground calibration. (3) Ground calibration (and verification) of focus vs. drive position must be done in 1-g on the ground. This calibration will be complicated by both the structural characteristics of the bipods and the fact that the CG of the translating portion of the SIM is not on the optical axis (thereby causing unwated rotations and changing the focus position vs. motor step and pot readout relationships). The SIM translating weight could be offloaded, but the calibration then becomes sensitive to any errors in offloading (both magnitude and direction). There are concerns as to whether a calibration to the required accuracy can be accomplished on the ground. (4) The choice of a potentiometer as the focus position sensor is questionable in terms of reliability for a five year mission. The results of SAO's study of items 1, 2 and 3 described above are presented in this report.
Spikes and matter inhomogeneities in massless scalar field models
NASA Astrophysics Data System (ADS)
Coley, A. A.; Lim, W. C.
2016-01-01
We shall discuss the general relativistic generation of spikes in a massless scalar field or stiff perfect fluid model. We first investigate orthogonally transitive (OT) G 2 stiff fluid spike models both heuristically and numerically, and give a new exact OT G 2 stiff fluid spike solution. We then present a new two-parameter family of non-OT G 2 stiff fluid spike solutions, obtained by the generalization of non-OT G 2 vacuum spike solutions to the stiff fluid case by applying Geroch's transformation on a Jacobs seed. The dynamics of these new stiff fluid spike solutions is qualitatively different from that of the vacuum spike solutions in that the matter (stiff fluid) feels the spike directly and the stiff fluid spike solution can end up with a permanent spike. We then derive the evolution equations of non-OT G 2 stiff fluid models, including a second perfect fluid, in full generality, and briefly discuss some of their qualitative properties and their potential numerical analysis. Finally, we discuss how a fluid, and especially a stiff fluid or massless scalar field, affects the physics of the generation of spikes.
He, Xiao-Tao; Wu, Rui-Xin; Xu, Xin-Yue; Wang, Jia; Yin, Yuan; Chen, Fa-Ming
2018-04-15
Accumulating evidence indicates that the physicochemical properties of biomaterials exert profound influences on stem cell fate decisions. However, matrix-based regulation selected through in vitro analyses based on a given cell population do not genuinely reflect the in vivo conditions, in which multiple cell types are involved and interact dynamically. This study constitutes the first investigation of how macrophages (Mφs) in stiffness-tunable transglutaminase cross-linked gelatin (TG-gel) affect the osteogenesis of bone marrow-derived mesenchymal stem cells (BMMSCs). When a single cell type was cultured, low-stiffness TG-gels promoted BMMSC proliferation, whereas high-stiffness TG-gels supported cell osteogenic differentiation. However, Mφs in high-stiffness TG-gels were more likely to polarize toward the pro-inflammatory M1 phenotype. Using either conditioned medium (CM)-based incubation or Transwell-based co-culture, we found that Mφs encapsulated in the low-stiffness matrix exerted a positive effect on the osteogenesis of co-cultured BMMSCs. Conversely, Mφs in high-stiffness TG-gels negatively affected cell osteogenic differentiation. When both cell types were cultured in the same TG-gel type and placed into the Transwell system, the stiffness-related influences of Mφs on BMMSCs were significantly altered; both the low- and high-stiffness matrix induced similar levels of BMMSC osteogenesis. Although the best material parameter for synergistically affecting Mφs and BMMSCs remains unknown, our data suggest that Mφ involvement in the co-culture system alters previously identified material-related influences on BMMSCs, such as matrix stiffness-related effects, which were identified based on a culture system involving a single cell type. Such Mφ-stem cell interactions should be considered when establishing proper matrix parameter-associated cell regulation in the development of biomimetic biomaterials for regenerative applications. The substrate stiffness of a scaffold plays critical roles in modulating both reparative cells, such as mesenchymal stem cells (MSCs), and immune cells, such as macrophages (Mφs). Although the influences of material stiffness on either Mφs or MSCs, have been extensively described, how the two cell types respond to matrix cues to dynamically affect each other in a three-dimensional (3D) biosystem remains largely unknown. Here, we report our findings that, in a platform wherein Mφs and bone marrow-derived MSCs coexist, matrix stiffness can influence stem cell fate through both direct matrix-associated regulation and indirect Mφ-based modulation. Our data support future studies of the MSC-Mφ-matrix interplay in the 3D context to optimize matrix parameters for the development of the next biomaterial. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Gómez, Fátima Somovilla; Lorza, Rubén Lostado; Bobadilla, Marina Corral; García, Rubén Escribano
2017-09-21
The kinematic behavior of models that are based on the finite element method (FEM) for modeling the human body depends greatly on an accurate estimate of the parameters that define such models. This task is complex, and any small difference between the actual biomaterial model and the simulation model based on FEM can be amplified enormously in the presence of nonlinearities. The current paper attempts to demonstrate how a combination of the FEM and the MRS methods with desirability functions can be used to obtain the material parameters that are most appropriate for use in defining the behavior of Finite Element (FE) models of the healthy human lumbar intervertebral disc (IVD). The FE model parameters were adjusted on the basis of experimental data from selected standard tests (compression, flexion, extension, shear, lateral bending, and torsion) and were developed as follows: First, three-dimensional parameterized FE models were generated on the basis of the mentioned standard tests. Then, 11 parameters were selected to define the proposed parameterized FE models. For each of the standard tests, regression models were generated using MRS to model the six stiffness and nine bulges of the healthy IVD models that were created by changing the parameters of the FE models. The optimal combination of the 11 parameters was based on three different adjustment criteria. The latter, in turn, were based on the combination of stiffness and bulges that were obtained from the standard test FE simulations. The first adjustment criteria considered stiffness and bulges to be equally important in the adjustment of FE model parameters. The second adjustment criteria considered stiffness as most important, whereas the third considered the bulges to be most important. The proposed adjustment methods were applied to a medium-sized human IVD that corresponded to the L3-L4 lumbar level with standard dimensions of width = 50 mm, depth = 35 mm, and height = 10 mm. Agreement between the kinematic behavior that was obtained with the optimized parameters and that obtained from the literature demonstrated that the proposed method is a powerful tool with which to adjust healthy IVD FE models when there are many parameters, stiffnesses, and bulges to which the models must adjust.
Somovilla Gómez, Fátima
2017-01-01
The kinematic behavior of models that are based on the finite element method (FEM) for modeling the human body depends greatly on an accurate estimate of the parameters that define such models. This task is complex, and any small difference between the actual biomaterial model and the simulation model based on FEM can be amplified enormously in the presence of nonlinearities. The current paper attempts to demonstrate how a combination of the FEM and the MRS methods with desirability functions can be used to obtain the material parameters that are most appropriate for use in defining the behavior of Finite Element (FE) models of the healthy human lumbar intervertebral disc (IVD). The FE model parameters were adjusted on the basis of experimental data from selected standard tests (compression, flexion, extension, shear, lateral bending, and torsion) and were developed as follows: First, three-dimensional parameterized FE models were generated on the basis of the mentioned standard tests. Then, 11 parameters were selected to define the proposed parameterized FE models. For each of the standard tests, regression models were generated using MRS to model the six stiffness and nine bulges of the healthy IVD models that were created by changing the parameters of the FE models. The optimal combination of the 11 parameters was based on three different adjustment criteria. The latter, in turn, were based on the combination of stiffness and bulges that were obtained from the standard test FE simulations. The first adjustment criteria considered stiffness and bulges to be equally important in the adjustment of FE model parameters. The second adjustment criteria considered stiffness as most important, whereas the third considered the bulges to be most important. The proposed adjustment methods were applied to a medium-sized human IVD that corresponded to the L3–L4 lumbar level with standard dimensions of width = 50 mm, depth = 35 mm, and height = 10 mm. Agreement between the kinematic behavior that was obtained with the optimized parameters and that obtained from the literature demonstrated that the proposed method is a powerful tool with which to adjust healthy IVD FE models when there are many parameters, stiffnesses, and bulges to which the models must adjust. PMID:28934161
Golkar, Mahsa A.; Sobhani Tehrani, Ehsan; Kearney, Robert E.
2017-01-01
Dynamic joint stiffness is a dynamic, nonlinear relationship between the position of a joint and the torque acting about it, which can be used to describe the biomechanics of the joint and associated limb(s). This paper models and quantifies changes in ankle dynamic stiffness and its individual elements, intrinsic and reflex stiffness, in healthy human subjects during isometric, time-varying (TV) contractions of the ankle plantarflexor muscles. A subspace, linear parameter varying, parallel-cascade (LPV-PC) algorithm was used to identify the model from measured input position perturbations and output torque data using voluntary torque as the LPV scheduling variable (SV). Monte-Carlo simulations demonstrated that the algorithm is accurate, precise, and robust to colored measurement noise. The algorithm was then used to examine stiffness changes associated with TV isometric contractions. The SV was estimated from the Soleus EMG using a Hammerstein model of EMG-torque dynamics identified from unperturbed trials. The LPV-PC algorithm identified (i) a non-parametric LPV impulse response function (LPV IRF) for intrinsic stiffness and (ii) a LPV-Hammerstein model for reflex stiffness consisting of a LPV static nonlinearity followed by a time-invariant state-space model of reflex dynamics. The results demonstrated that: (a) intrinsic stiffness, in particular ankle elasticity, increased significantly and monotonically with activation level; (b) the gain of the reflex pathway increased from rest to around 10–20% of subject's MVC and then declined; and (c) the reflex dynamics were second order. These findings suggest that in healthy human ankle, reflex stiffness contributes most at low muscle contraction levels, whereas, intrinsic contributions monotonically increase with activation level. PMID:28579954
Russo, Cesare; Jin, Zhezhen; Palmieri, Vittorio; Homma, Shunichi; Rundek, Tatjana; Elkind, Mitchell S V; Sacco, Ralph L; Di Tullio, Marco R
2012-08-01
Increased arterial stiffness and wave reflection have been reported in heart failure with normal ejection fraction (HFNEF) and in asymptomatic left ventricular (LV) diastolic dysfunction, a precursor of HFNEF. It is unclear whether women, who have higher frequency of HFNEF, are more vulnerable than men to the deleterious effects of arterial stiffness on LV diastolic function. We investigated, in a large community-based cohort, whether sex differences exist in the relationship among arterial stiffness, wave reflection, and LV diastolic function. Arterial stiffness and wave reflection were assessed in 983 participants from the Cardiovascular Abnormalities and Brain Lesions study using applanation tonometry. The central pulse pressure/stroke volume index, total arterial compliance, pulse pressure amplification, and augmentation index were used as parameters of arterial stiffness and wave reflection. LV diastolic function was evaluated by 2-dimensional echocardiography and tissue-Doppler imaging. Arterial stiffness and wave reflection were greater in women compared with men, independent of body size and heart rate (all P<0.01), and showed inverse relationships with parameters of diastolic function in both sexes. Further adjustment for cardiovascular risk factors attenuated these relationships; however, a higher central pulse pressure/stroke volume index predicted LV diastolic dysfunction in women (odds ratio, 1.54; 95% confidence intervals, 1.03 to 2.30) and men (odds ratio, 2.09; 95% confidence interval, 1.30 to 3.39), independent of other risk factors. In conclusion, in our community-based cohort study, higher arterial stiffness was associated with worse LV diastolic function in men and women. Women's higher arterial stiffness, independent of body size, may contribute to their greater susceptibility to develop HFNEF.
Alomari, Ali Hamed; Wille, Marie-Luise; Langton, Christian M
2018-02-01
Conventional mechanical testing is the 'gold standard' for assessing the stiffness (N mm -1 ) and strength (MPa) of bone, although it is not applicable in-vivo since it is inherently invasive and destructive. The mechanical integrity of a bone is determined by its quantity and quality; being related primarily to bone density and structure respectively. Several non-destructive, non-invasive, in-vivo techniques have been developed and clinically implemented to estimate bone density, both areal (dual-energy X-ray absorptiometry (DXA)) and volumetric (quantitative computed tomography (QCT)). Quantitative ultrasound (QUS) parameters of velocity and attenuation are dependent upon both bone quantity and bone quality, although it has not been possible to date to transpose one particular QUS parameter into separate estimates of quantity and quality. It has recently been shown that ultrasound transit time spectroscopy (UTTS) may provide an accurate estimate of bone density and hence quantity. We hypothesised that UTTS also has the potential to provide an estimate of bone structure and hence quality. In this in-vitro study, 16 human femoral bone samples were tested utilising three techniques; UTTS, micro computed tomography (μCT), and mechanical testing. UTTS was utilised to estimate bone volume fraction (BV/TV) and two novel structural parameters, inter-quartile range of the derived transit time (UTTS-IQR) and the transit time of maximum proportion of sonic-rays (TTMP). μCT was utilised to derive BV/TV along with several bone structure parameters. A destructive mechanical test was utilised to measure the stiffness and strength (failure load) of the bone samples. BV/TV was calculated from the derived transit time spectrum (TTS); the correlation coefficient (R 2 ) with μCT-BV/TV was 0.885. For predicting mechanical stiffness and strength, BV/TV derived by both μCT and UTTS provided the strongest correlation with mechanical stiffness (R 2 =0.567 and 0.618 respectively) and mechanical strength (R 2 =0.747 and 0.736 respectively). When respective structural parameters were incorporated to BV/TV, multiple regression analysis indicated that none of the μCT histomorphometric parameters could improve the prediction of mechanical stiffness and strength, while for UTTS, adding TTMP to BV/TV increased the prediction of mechanical stiffness to R 2 =0.711 and strength to R 2 =0.827. It is therefore envisaged that UTTS may have the ability to estimate BV/TV along with providing an improved prediction of osteoporotic fracture risk, within routine clinical practice in the future. Copyright © 2017 Elsevier Inc. All rights reserved.
Dynamic characteristics of a vibrating beam with periodic variation in bending stiffness
NASA Technical Reports Server (NTRS)
Townsend, John S.
1987-01-01
A detailed dynamic analysis is performed of a vibrating beam with bending stiffness periodic in the spatial coordinate. The effects of system parameters on beam response are explored with a perturbation expansion technique. It is found that periodic stiffness acts to modulate the modal displacements from the characteristic shape of a simple sine wave. The results are verified by a finite element solution and through experimental testing.
Biomechanical study of anterior spinal instrumentation configurations
Cloutier, Luc P.; Grimard, Guy
2007-01-01
The biomechanical impact of the surgical instrumentation configuration for spine surgery is hard to evaluate by the surgeons in pre-operative situation. This study was performed to evaluate different configurations of the anterior instrumentation of the spine, with simulated post-operative conditions, to recommend configurations to the surgeons. Four biomechanical parameters of the anterior instrumentation with simulated post-operative conditions have been studied. They were the screw diameter (5.5–7.5 mm) and its angle (0°–22.5°), the bone grip of the screw (mono–bi cortical) and the amount of instrumented levels (5–8). Eight configurations were tested using an experimental plan with instrumented synthetic spinal models. A follower load was applied and the models were loaded in flexion, torsion and lateral bending. At 5 Nm, average final stiffness was greater in flexion (0.92 Nm/°) than in lateral bending (0.56 Nm/°) and than in torsion (0.26 Nm/°). The screw angle was the parameter influencing the most the final stiffness and the coupling behaviors. It has a significant effect (p ≤ 0.05) on increasing the final stiffness for a 22.5° screw angle in flexion and for a coronal screw angle (0°) in lateral bending. The bi-cortical bone grip of the screw significantly increased the initial stiffness in flexion and lateral bending. Mathematical models representing the behavior of an instrumented spinal model have been used to identify optimal instrumentation configurations. A variation of the angle of the screw from 22.5° to 0° gave a global final stiffness diminution of 13% and a global coupling diminution of 40%. The screw angle was the most important parameter affecting the stiffness and the coupling of the instrumented spine with simulated post-operative conditions. Information about the effect of four different biomechanical parameters will be helpful in preoperative situations to guide surgeons in their clinical choices. PMID:17205240
Nekkanty, Srikant; Yerramshetty, Janardhan; Kim, Do-Gyoon; Zauel, Roger; Johnson, Evan; Cody, Dianna D.; Yeni, Yener N.
2013-01-01
Stress magnitude and variability as estimated from large scale finite element (FE) analyses have been associated with compressive strength of human vertebral cancellous cores but these relationships have not been explored for whole vertebral bodies. In this study, the objectives were to investigate the relationship of FE-calculated stress distribution parameters with experimentally determined strength, stiffness, and displacement based ductility measures in human whole vertebral bodies, investigate the effect of endplate loading conditions on vertebral stiffness, strength, and ductility and test the hypothesis that endplate topography affects vertebral ductility and stress distributions. Eighteen vertebral bodies (T6-L3 levels; 4 female and 5 male cadavers, aged 40-98 years) were scanned using a flat panel CT system and followed with axial compression testing with Wood’s metal as filler material to maintain flat boundaries between load plates and specimens. FE models were constructed using reconstructed CT images and filler material was added digitally. Two different FE models with different filler material modulus simulating Wood’s metal and intervertebral disc (W-layer and D-layer models) were used. Element material modulus to cancellous bone was based on image gray value. Average, standard deviation, and coefficient of variation of von Mises stress in vertebral bone for W-layer and D-layer models and also the ratios of FE parameters from the two models (W/D) were calculated. Inferior and superior endplate surface topographical distribution parameters were calculated. Experimental stiffness, maximum load and work to fracture had the highest correlation with FE-calculated stiffness while experimental ductility measures had highest correlations with FE-calculated average von Mises stress and W-layer to D-layer stiffness ratio. Endplate topography of the vertebra was also associated with its structural ductility and the distribution parameter that best explained this association was kurtosis of inferior endplate topography. Our results indicate that endplate topography variations may provide insight into the mechanisms responsible for vertebral fractures. PMID:20633709
Impact of gradation and moisture content on stiffness parameters of base materials : final report.
DOT National Transportation Integrated Search
2016-01-01
The performance of flexible pavement depends on the mechanical characteristics of its base layer. The mechanical : characteristics such as stiffness and deformation resistance depend on many factors such as the material gradation : fines content, moi...
Lower Body Stiffness Modulation Strategies in Well Trained Female Athletes.
Millett, Emma L; Moresi, Mark P; Watsford, Mark L; Taylor, Paul G; Greene, David A
2016-10-01
Millett, EL, Moresi, MP, Watsford, ML, Taylor, PG, and Greene, DA. Lower body stiffness modulation strategies in well trained female athletes. J Strength Cond Res 30(10): 2845-2856, 2016-Lower extremity stiffness quantifies the relationship between the amount of leg compression and the external load to which the limb are subjected. This study aimed to assess differences in leg and joint stiffness and the subsequent kinematic and kinetic control mechanisms between athletes from various training backgrounds. Forty-seven female participants (20 nationally identified netballers, 13 high level endurance athletes and 14 age and gender matched controls) completed a maximal unilateral countermovement jump, drop jump and horizontal jump to assess stiffness. Leg stiffness, joint stiffness and associated mechanical parameters were assessed with a 10 camera motion analysis system and force plate. No significant differences were evident for leg stiffness measures between athletic groups for any of the tasks (p = 0.321-0.849). However, differences in joint stiffness and its contribution to leg stiffness, jump performance outcome measures and stiffness control mechanisms were evident between all groups. Practitioners should consider the appropriateness of the task utilised in leg stiffness screening. Inclusion of mechanistic and/or more sports specific tasks may be more appropriate for athletic groups.
Parameter Optimization and Electrode Improvement of Rotary Stepper Micromotor
NASA Astrophysics Data System (ADS)
Sone, Junji; Mizuma, Toshinari; Mochizuki, Shunsuke; Sarajlic, Edin; Yamahata, Christophe; Fujita, Hiroyuki
We developed a three-phase electrostatic stepper micromotor and performed a numerical simulation to improve its performance for practical use and to optimize its design. We conducted its circuit simulation by simplifying its structure, and the effect of springback force generated by supported mechanism using flexures was considered. And we considered new improvement method for electrodes. This improvement and other parameter optimizations achieved the low voltage drive of micromotor.
Numerical and experimental study on multi-pass laser bending of AH36 steel strips
NASA Astrophysics Data System (ADS)
Fetene, Besufekad N.; Kumar, Vikash; Dixit, Uday S.; Echempati, Raghu
2018-02-01
Laser bending is a process of bending of plates, small sized sheets, strips and tubes, in which a moving or stationary laser beam heats the workpiece to achieve the desired curvature due to thermal stresses. Researchers studied the effects of different process parameters related to the laser source, material and workpiece geometry on laser bending of metal sheets. The studies are focused on large sized sheets. The workpiece geometry parameters like sheet thickness, length and width also affect the bend angle considerably. In this work, the effects of width and thickness on multi-pass laser bending of AH36 steel strips were studied experimentally and numerically. Finite element model using ABAQUS® was developed to investigate the size effect on the prediction of the bend angle. Microhardness and flexure tests showed an increase in the flexural strength as well as microhardness in the scanned zone. The microstructures of the bent strips also supported the physical observations.
DOT National Transportation Integrated Search
2005-11-01
The stiffness (elastic modulus and shear modulus) and Poisson's ratio of the base and sublayers are important parameters in the design and quality assurance during construction of highway pavements. The new highway construction guide proposed by AASH...
Omer, Gedikli; Gokhan, Aksan; Adem, Uzun; Sabri, Demircan; Korhan, Soylu
2014-01-01
Background: Current guidelines recommend clinical risk scoring systems for the patients diagnosed and determinated treatment strategy with in Non-ST-elevation elevation myocardial infarction (NSTEMI). Previous studies demonstrated association between aortic elasticity properties, stiffness and severity CAD. However, the associations between Aortic stiffness, elasticity properties and clinical risk scores have not been investigated. In the present study we have evaluated the relation between the Global Registry of Acute Coronary Events (GRACE) risk score and aortic stiffness in patients with NSTEMI. Method: We prospectively analyzed 87 consecutive patients with NSTEMI. Aortic elastic parameter and stiffness parameter were calculated from the echocardiographically derived thoracic aortic diameters (mm/m2), and the measurement of pulse pressure obtained by cuff sphygmomanometry. We have categorized the patients in to two groups as low ((n = 45) (GRACE risk score ≤ 140)) and high ((n = 42) (GRACE risk score > 140)) risk group according to GRACE risk score and compare the both groups. Results: Table 1 shows baseline characteristics of patients. Our study showed that Aortic strain was significantly low (3.5 ± 1.4, 7.9 ± 2.3 respectively, p < 0.001) and aortic stiffness index was significantly high (3.9 ± 0.38; 3 ± 0.35, respectively, p < 0.001) in the high risk group values compared to those with low risk group. The aortic stiffness index was the only independent predictor of GRACE risk score (OR: 119.390; 95% CI: 2.925-4872.8; p = 0.011) in multivariate analysis. Conclusion: We found a significant correlation between aortic stiffness, impaired elasticity and GRACE risk score. Aortic stiffness index was the only independent variable of the high GRACE risk score. The inclusion of aortic stiffness into the GRACE risk score could allow improved risk classification of patients with ACS at admission and this may be important in the diagnosis, follow up and treatment of the patients. PMID:25356178
Omer, Gedikli; Gokhan, Aksan; Adem, Uzun; Sabri, Demircan; Korhan, Soylu
2014-01-01
Current guidelines recommend clinical risk scoring systems for the patients diagnosed and determinated treatment strategy with in Non-ST-elevation elevation myocardial infarction (NSTEMI). Previous studies demonstrated association between aortic elasticity properties, stiffness and severity CAD. However, the associations between Aortic stiffness, elasticity properties and clinical risk scores have not been investigated. In the present study we have evaluated the relation between the Global Registry of Acute Coronary Events (GRACE) risk score and aortic stiffness in patients with NSTEMI. We prospectively analyzed 87 consecutive patients with NSTEMI. Aortic elastic parameter and stiffness parameter were calculated from the echocardiographically derived thoracic aortic diameters (mm/m(2)), and the measurement of pulse pressure obtained by cuff sphygmomanometry. We have categorized the patients in to two groups as low ((n = 45) (GRACE risk score ≤ 140)) and high ((n = 42) (GRACE risk score > 140)) risk group according to GRACE risk score and compare the both groups. Table 1 shows baseline characteristics of patients. Our study showed that Aortic strain was significantly low (3.5 ± 1.4, 7.9 ± 2.3 respectively, p < 0.001) and aortic stiffness index was significantly high (3.9 ± 0.38; 3 ± 0.35, respectively, p < 0.001) in the high risk group values compared to those with low risk group. The aortic stiffness index was the only independent predictor of GRACE risk score (OR: 119.390; 95% CI: 2.925-4872.8; p = 0.011) in multivariate analysis. We found a significant correlation between aortic stiffness, impaired elasticity and GRACE risk score. Aortic stiffness index was the only independent variable of the high GRACE risk score. The inclusion of aortic stiffness into the GRACE risk score could allow improved risk classification of patients with ACS at admission and this may be important in the diagnosis, follow up and treatment of the patients.
Increased arterial stiffness parameters in panic disorder patients in long term treatment period.
Yanartas, Omer; Sunbul, Murat; Senkal, Zeynep; Durmus, Erdal; Kivrak, Tarik; Subasi, Nilufer; Karaer, Gulhan; Ergun, Serhat; Sari, Ibrahim; Sayar, Kemal
2016-01-01
The relationship between mental stress and cardiovascular disease has been shown in several studies. Panic disorder (PD) is also associated with cardiovascular disease due to increased risk of myocardial infarction. The aim of this study is to evaluate the association between arterial stiffness parameters and depression/anxiety scores in patients with PD. The study population consisted of 25 patients with PD and 25 age-sex-matched healthy controls. Depression and anxiety levels were evaluated by Beck Depression Inventory (BDI) and Beck Anxiety Inventory (BAI), respectively. Determination of arterial stiffness parameters was conducted using a Mobil-O-Graph arteriograph system that detected signals from the brachial artery. While baseline characteristics were similar between two groups, BDI and BAI scores were significantly higher in patients with PD (p < 0.005). The pulse wave velocity (PWV) and Augmentation Index (AIx) were also significantly higher in patients with PD (p = 0.001, p = 0.006). There was a moderate correlation between PWV and AIx with BAI scores (r = 0.442, p = 0.001, r = 0.441, p = 0.001). AIx was also positively correlated with BDI scores (r = 0.415, p = 0.03). We demonstrated a significant relationship between arterial stiffness parameters and anxiety/depression scores in patients with PD who receive antidepressant treatment.
Arterial stiffness and cardiac functions in patients with chronic venous disease.
Ozpelit, E; Ozpelit, M E; Albayrak, G; Karabay, O; Nesli Sahin, B; Gonencer, J Z; Badak, O
2015-12-01
Although the venous system is in direct continuity with the heart and the arterial system, it is not known whether chronic venous disease (CVD) has any impact on either of these. The aims of this study were to investigate the global functions of the left and right heart, and also arterial stiffness parameters in patients with CVD. Forty-eight patients with primary stage C4-C6 CVD were enrolled into the study. The control group consisted of 39 age/sex and Body Mass Index matched healthy volunteers. All of the patients underwent detailed echocardiographic examination with further focus on Doppler and tissue Doppler (TD) parameters of the left and right ventricle. Arterial stiffness was evaluated via applanation tonometry in each patient. The left atrial area (LAA) and interventricular septum thickness were slightly increased in patients with CVD. Regarding Doppler and tissue Doppler measurements of the LV, all of the parameters were similar among the groups, while RV tissue Doppler systolic velocity and TAPSE were higher in patients with CVD. Among the arterial stiffness parameters, central aortic pressure, augmentation index, and pulse wave velocity were slightly higher in patients with CVD. The results of this study indicated that CVD may be associated with a subclinical disease state in the arterial system and also in the heart. Further studies are needed to confirm this association and to describe the possible mechanisms.
Effects of Simulated Functional Loading Conditions on Dentin, Composite, and Laminate Structures
Walker, Mary P.; Teitelbaum, Heather K.; Eick, J. David; Williams, Karen B.
2008-01-01
Use of composite restorations continues to increase, tempered by more potential problems when placed in posterior dentition. Thus, it is essential to understand how these materials function under stress-bearing clinical conditions. Since mastication is difficult to replicate in the laboratory, cyclic loading is frequently used within in vitro evaluations but often employs traditional fatigue testing, which typically does not simulate occlusal loading because higher stresses and loading frequencies are used, so failure mechanisms may be different. The present investigation utilized relevant parameters (specimen size; loading frequency) to assess the effects of cyclic loading on flexural mechanical properties and fracture morphology of (coronal) dentin, composite, and dentin-adhesive-composite “laminate” structures. Incremental monitoring of flexural modulus on individual beams over 60,000 loading cycles revealed a gradual increase across materials; post-hoc comparisons indicated statistical significance only for 1 versus 60k cycles. Paired specimens were tested (one exposed to 60k loading cycles, one to static loading only), and comparisons of flexural modulus and strength showed statistically significantly higher values for cyclically-loaded specimens across materials, with no observable differences in fracture morphology. Localized reorganization of dentin collagen and polymer chains could have increased flexural modulus and strength during cyclic loading, which may have implications toward the life and failure mechanisms of clinical restorations and underlying tooth structure. PMID:18823019
Flexural-response of the McMurdo Ice Shelf to surface lake filling and drainage
NASA Astrophysics Data System (ADS)
Banwell, A. F.; MacAyeal, D. R.; Willis, I.; Macdonald, G. J.; Goodsell, B.
2017-12-01
Antarctic ice-shelf instability and break-up, as exhibited by the Larsen B ice shelf in 2002, remains one of the most difficult glaciological processes to observe directly. It is, however, vital to do so because ice-shelf breakup has the potential to influence the buttressing controls on inland ice discharge, and thus to affect sea level. Several mechanisms enabling Larsen B style breakup have previously been proposed, including the ability of surface lakes to introduce ice-shelf fractures when they fill and drain. During the austral summer of 2016/2017, we monitored the filling and draining of four surface lakes on the McMurdo Ice Shelf, Antarctica, and the effect of these processes on ice-shelf flexure. Water-depth data from pressure sensors reveal that two lakes filled to >2 m in depth and subsequently drained over multiple week timescales, which had a simultaneous effect on vertical ice deflection in the area. Differential GPS data from 12 receivers over three months show that vertical deflection varies as a function of distance from the maximum load change (i.e. at the lake centre). Using remote sensing techniques applied to both Landsat 8 and Worldview imagery, we also quantify the meltwater volume in these two lakes through the melt season, which, together with the vertical deflection data, are used to constrain key flexural parameter values in numerical models of ice-shelf flexure.
Does artificial aging affect mechanical properties of CAD/CAM composite materials.
Egilmez, Ferhan; Ergun, Gulfem; Cekic-Nagas, Isil; Vallittu, Pekka K; Lassila, Lippo V J
2018-01-01
The purpose of this study was to determine the flexural strength and Weibull characteristics of different CAD/CAM materials after different in vitro aging conditions. The specimens were randomly assigned to one of the six in vitro aging conditions: (1) water storage (37°C, 3 weeks), (2) boiling water (24h), (3) hydrochloric acid exposure (pH: 1.2, 24h), (4) autoclave treatment (134°C, 200kPa, 12h), (5) thermal cycling (5000 times, 5-55°C), (6) cyclic loading (100N, 50,000 cycles). No treatment was applied to the specimens in control group. Three-point bending test was used for the calculation of flexural strength. The reliability of the strength was assessed by Weibull distribution. Surface roughness and topography was examined by coherence scanning interferometry. Evaluated parameters were compared using the Kruskall-Wallis or Mann-Whitney U test. Water storage, autoclave treatment and thermal cycling significantly decreased the flexural strength of all materials (p<0.05), whereas HCl exposure or cyclic loading did not affect the properties (p>0.05). Weibull moduli of Cerasmart™ and Lava™ Ultimate were similar with control. Vita Enamic ® exhibited similar Weibull moduli in all aging groups except the HCl treated group (p>0.05). R a values of Cerasmart™ and Lava™ Ultimate were in the range of 0.053-0.088μm in the aged groups. However R a results of Vita Enamic ® were larger than 0.2μm. Flexural strength of newly developed restorative CAD/CAM materials was significantly decreased by artificial aging. Cyclic loading or HCl exposure does not affect to the flexural strength and structural reliability of Cerasmart™ and Lava™ Ultimate. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
Phani, M Kalyan; Kumar, Anish; Jayakumar, T; Samwer, Konrad
2015-01-01
Summary The distribution of elastic stiffness and damping of individual phases in an α + β titanium alloy (Ti-6Al-4V) measured by using atomic force acoustic microscopy (AFAM) is reported in the present study. The real and imaginary parts of the contact stiffness k * are obtained from the contact-resonance spectra and by using these two quantities, the maps of local elastic stiffness and the damping factor are derived. The evaluation of the data is based on the mass distribution of the cantilever with damped flexural modes. The cantilever dynamics model considering damping, which was proposed recently, has been used for mapping of indentation modulus and damping of different phases in a metallic structural material. The study indicated that in a Ti-6Al-4V alloy the metastable β phase has the minimum modulus and the maximum damping followed by α′- and α-phases. Volume fractions of the individual phases were determined by using a commercial material property evaluation software and were validated by using X-ray diffraction (XRD) and electron back-scatter diffraction (EBSD) studies on one of the heat-treated samples. The volume fractions of the phases and the modulus measured through AFAM are used to derive average modulus of the bulk sample which is correlated with the bulk elastic properties obtained by ultrasonic velocity measurements. The average modulus of the specimens estimated by AFAM technique is found to be within 5% of that obtained by ultrasonic velocity measurements. The effect of heat treatments on the ultrasonic attenuation in the bulk sample could also be understood based on the damping measurements on individual phases using AFAM. PMID:25977847
Low-Velocity Impact Response of Sandwich Beams with Functionally Graded Core
NASA Technical Reports Server (NTRS)
Apetre, N. A.; Sankar, B. V.; Ambur, D. R.
2006-01-01
The problem of low-speed impact of a one-dimensional sandwich panel by a rigid cylindrical projectile is considered. The core of the sandwich panel is functionally graded such that the density, and hence its stiffness, vary through the thickness. The problem is a combination of static contact problem and dynamic response of the sandwich panel obtained via a simple nonlinear spring-mass model (quasi-static approximation). The variation of core Young's modulus is represented by a polynomial in the thickness coordinate, but the Poisson's ratio is kept constant. The two-dimensional elasticity equations for the plane sandwich structure are solved using a combination of Fourier series and Galerkin method. The contact problem is solved using the assumed contact stress distribution method. For the impact problem we used a simple dynamic model based on quasi-static behavior of the panel - the sandwich beam was modeled as a combination of two springs, a linear spring to account for the global deflection and a nonlinear spring to represent the local indentation effects. Results indicate that the contact stiffness of thc beam with graded core Increases causing the contact stresses and other stress components in the vicinity of contact to increase. However, the values of maximum strains corresponding to the maximum impact load arc reduced considerably due to grading of thc core properties. For a better comparison, the thickness of the functionally graded cores was chosen such that the flexural stiffness was equal to that of a beam with homogeneous core. The results indicate that functionally graded cores can be used effectively to mitigate or completely prevent impact damage in sandwich composites.
Phani, M Kalyan; Kumar, Anish; Jayakumar, T; Arnold, Walter; Samwer, Konrad
2015-01-01
The distribution of elastic stiffness and damping of individual phases in an α + β titanium alloy (Ti-6Al-4V) measured by using atomic force acoustic microscopy (AFAM) is reported in the present study. The real and imaginary parts of the contact stiffness k (*) are obtained from the contact-resonance spectra and by using these two quantities, the maps of local elastic stiffness and the damping factor are derived. The evaluation of the data is based on the mass distribution of the cantilever with damped flexural modes. The cantilever dynamics model considering damping, which was proposed recently, has been used for mapping of indentation modulus and damping of different phases in a metallic structural material. The study indicated that in a Ti-6Al-4V alloy the metastable β phase has the minimum modulus and the maximum damping followed by α'- and α-phases. Volume fractions of the individual phases were determined by using a commercial material property evaluation software and were validated by using X-ray diffraction (XRD) and electron back-scatter diffraction (EBSD) studies on one of the heat-treated samples. The volume fractions of the phases and the modulus measured through AFAM are used to derive average modulus of the bulk sample which is correlated with the bulk elastic properties obtained by ultrasonic velocity measurements. The average modulus of the specimens estimated by AFAM technique is found to be within 5% of that obtained by ultrasonic velocity measurements. The effect of heat treatments on the ultrasonic attenuation in the bulk sample could also be understood based on the damping measurements on individual phases using AFAM.
Optical Phase Measurements of Disorder Strength Link Microstructure to Cell Stiffness.
Eldridge, Will J; Steelman, Zachary A; Loomis, Brianna; Wax, Adam
2017-02-28
There have been sustained efforts on the part of cell biologists to understand the mechanisms by which cells respond to mechanical stimuli. To this end, many rheological tools have been developed to characterize cellular stiffness. However, measurement of cellular viscoelastic properties has been limited in scope by the nature of most microrheological methods, which require direct mechanical contact, applied at the single-cell level. In this article, we describe, to our knowledge, a new analysis approach for quantitative phase imaging that relates refractive index variance to disorder strength, a parameter that is linked to cell stiffness. Significantly, both disorder strength and cell stiffness are measured with the same phase imaging system, presenting a unique alternative for label-free, noncontact, single-shot imaging of cellular rheologic properties. To demonstrate the potential applicability of the technique, we measure phase disorder strength and shear stiffness across five cellular populations with varying mechanical properties and demonstrate an inverse relationship between these two parameters. The existence of this relationship suggests that predictions of cell mechanical properties can be obtained from examining the disorder strength of cell structure using this, to our knowledge, novel, noncontact technique. Copyright © 2017 Biophysical Society. Published by Elsevier Inc. All rights reserved.
Wu, Bitao; Lu, Huaxi; Chen, Bo; Gao, Zhicheng
2017-01-01
A finite model updating method that combines dynamic-static long-gauge strain responses is proposed for highway bridge static loading tests. For this method, the objective function consisting of static long-gauge stains and the first order modal macro-strain parameter (frequency) is established, wherein the local bending stiffness, density and boundary conditions of the structures are selected as the design variables. The relationship between the macro-strain and local element stiffness was studied first. It is revealed that the macro-strain is inversely proportional to the local stiffness covered by the long-gauge strain sensor. This corresponding relation is important for the modification of the local stiffness based on the macro-strain. The local and global parameters can be simultaneously updated. Then, a series of numerical simulation and experiments were conducted to verify the effectiveness of the proposed method. The results show that the static deformation, macro-strain and macro-strain modal can be predicted well by using the proposed updating model. PMID:28753912
Wu, Bitao; Lu, Huaxi; Chen, Bo; Gao, Zhicheng
2017-07-19
A finite model updating method that combines dynamic-static long-gauge strain responses is proposed for highway bridge static loading tests. For this method, the objective function consisting of static long-gauge stains and the first order modal macro-strain parameter (frequency) is established, wherein the local bending stiffness, density and boundary conditions of the structures are selected as the design variables. The relationship between the macro-strain and local element stiffness was studied first. It is revealed that the macro-strain is inversely proportional to the local stiffness covered by the long-gauge strain sensor. This corresponding relation is important for the modification of the local stiffness based on the macro-strain. The local and global parameters can be simultaneously updated. Then, a series of numerical simulation and experiments were conducted to verify the effectiveness of the proposed method. The results show that the static deformation, macro-strain and macro-strain modal can be predicted well by using the proposed updating model.
NASA Astrophysics Data System (ADS)
Koltsov, A. G.; Shamutdinov, A. H.; Blokhin, D. A.; Krivonos, E. V.
2018-01-01
A new classification of parallel kinematics mechanisms on symmetry coefficient, being proportional to mechanism stiffness and accuracy of the processing product using the technological equipment under study, is proposed. A new version of the Stewart platform with a high symmetry coefficient is presented for analysis. The workspace of the mechanism under study is described, this space being a complex solid figure. The workspace end points are reached by the center of the mobile platform which moves in parallel related to the base plate. Parameters affecting the processing accuracy, namely the static and dynamic stiffness, natural vibration frequencies are determined. The capability assessment of the mechanism operation under various loads, taking into account resonance phenomena at different points of the workspace, was conducted. The study proved that stiffness and therefore, processing accuracy with the use of the above mentioned mechanisms are comparable with the stiffness and accuracy of medium-sized series-produced machines.
Stiffness measurement of a biomaterial by optical manipulation of microparticle
NASA Astrophysics Data System (ADS)
Kim, Jung-Dae; Waleed, Muhammad; Lee, Yong-Gu
2013-02-01
Since the discovery of the trapping nature of laser beam, optical tweezers have been extensively employed to measure various parameters at micro/nano level. Optical tweezers show exceptional sensitivity to weak forces making it one of the most sensitive force measurement devices. In this work, we present a technique to measure the stiffness of a biomaterial at different points. For this purpose, a microparticle stuck at the bottom of the dish is illuminated by the trapping laser and respective QPD signal as a function of the distance between the focus of the laser and the center of the microparticle is monitored. After this, microparticle is trapped and manipulated towards the target biomaterial and when it touches the cell membrane, QPD signal shows variation. By comparing two different QPD signals and measuring the trap stiffness, a technique is described to measure the stiffness of the biomaterial at a particular point. We believe that this parameter can be used as a tool to identify and classify different biomaterials.
Jalaleddini, Kian; Tehrani, Ehsan Sobhani; Kearney, Robert E
2017-06-01
The purpose of this paper is to present a structural decomposition subspace (SDSS) method for decomposition of the joint torque to intrinsic, reflexive, and voluntary torques and identification of joint dynamic stiffness. First, it formulates a novel state-space representation for the joint dynamic stiffness modeled by a parallel-cascade structure with a concise parameter set that provides a direct link between the state-space representation matrices and the parallel-cascade parameters. Second, it presents a subspace method for the identification of the new state-space model that involves two steps: 1) the decomposition of the intrinsic and reflex pathways and 2) the identification of an impulse response model of the intrinsic pathway and a Hammerstein model of the reflex pathway. Extensive simulation studies demonstrate that SDSS has significant performance advantages over some other methods. Thus, SDSS was more robust under high noise conditions, converging where others failed; it was more accurate, giving estimates with lower bias and random errors. The method also worked well in practice and yielded high-quality estimates of intrinsic and reflex stiffnesses when applied to experimental data at three muscle activation levels. The simulation and experimental results demonstrate that SDSS accurately decomposes the intrinsic and reflex torques and provides accurate estimates of physiologically meaningful parameters. SDSS will be a valuable tool for studying joint stiffness under functionally important conditions. It has important clinical implications for the diagnosis, assessment, objective quantification, and monitoring of neuromuscular diseases that change the muscle tone.
Modeling, Modal Properties, and Mesh Stiffness Variation Instabilities of Planetary Gears
NASA Technical Reports Server (NTRS)
Parker, Robert G.; Lin, Jian; Krantz, Timothy L. (Technical Monitor)
2001-01-01
Planetary gear noise and vibration are primary concerns in their applications in helicopters, automobiles, aircraft engines, heavy machinery and marine vehicles. Dynamic analysis is essential to the noise and vibration reduction. This work analytically investigates some critical issues and advances the understanding of planetary gear dynamics. A lumped-parameter model is built for the dynamic analysis of general planetary gears. The unique properties of the natural frequency spectra and vibration modes are rigorously characterized. These special structures apply for general planetary gears with cyclic symmetry and, in practically important case, systems with diametrically opposed planets. The special vibration properties are useful for subsequent research. Taking advantage of the derived modal properties, the natural frequency and vibration mode sensitivities to design parameters are investigated. The key parameters include mesh stiffnesses, support/bearing stiffnesses, component masses, moments of inertia, and operating speed. The eigen-sensitivities are expressed in simple, closed-form formulae associated with modal strain and kinetic energies. As disorders (e.g., mesh stiffness variation. manufacturing and assembling errors) disturb the cyclic symmetry of planetary gears, their effects on the free vibration properties are quantitatively examined. Well-defined veering rules are derived to identify dramatic changes of natural frequencies and vibration modes under parameter variations. The knowledge of free vibration properties, eigen-sensitivities, and veering rules provide important information to effectively tune the natural frequencies and optimize structural design to minimize noise and vibration. Parametric instabilities excited by mesh stiffness variations are analytically studied for multi-mesh gear systems. The discrepancies of previous studies on parametric instability of two-stage gear chains are clarified using perturbation and numerical methods. The operating conditions causing parametric instabilities are expressed in closed-form suitable for design guidance. Using the well-defined modal properties of planetary gears, the effects of mesh parameters on parametric instability are analytically identified. Simple formulae are obtained to suppress particular instabilities by adjusting contact ratios and mesh phasing.
Code of Federal Regulations, 2012 CFR
2012-10-01
... with no openings. (r) Steel means steel and materials with which structures can be made equivalent to steel with respect to such parameters as yield strength, total deflection, flexural life, or resistance.... (i) Superstructure means a deck structure on the freeboard deck, extending from side to side of the...
Fellinger, Michael R.; Hector, Jr., Louis G.; Trinkle, Dallas R.
2016-11-29
Here, we present computed datasets on changes in the lattice parameter and elastic stiffness coefficients of BCC Fe due to substitutional Al, B, Cu, Mn, and Si solutes, and octahedral interstitial C and N solutes. The data is calculated using the methodology based on density functional theory (DFT). All the DFT calculations were performed using the Vienna Ab initio Simulations Package (VASP). The data is stored in the NIST dSpace repository.
NASA Astrophysics Data System (ADS)
Wang, Guang-yuan; Guan, Xin; Cao, Dong-jing; Tang, Shao-fan; Chen, Xiang; Liang, Lu; Zheng, Gang-tie
2017-11-01
With the raise of resolution, optical payloads are becoming increasingly sensitive to satellite jitter. An approach where the entire spacecraft is pointed with great accuracy requires sophisticated and expensive bus design. In an effort to lower the overall cost of space missions that require highly stable line-of-sight pointing, a method of separating the bus and the payload with low frequency isolators is proposed. This isolation system can block the transmission of disturbance and allow relatively large bus motion. However, if the isolator is linear then there is a trade-off between isolation and static deflection as the launch and the on-orbit stage have difference requirements on the isolation frequency. Otherwise, an extra locking system should be appended to protect the payload before getting into orbit, as the STABLE isolation system[1] and the MIM isolation system[2] did. To overcome this limitation, an alternative approach is to design a nonlinear isolator with high-static stiffness during launch and low dynamic stiffness on orbit. Several specially designed nonlinear isolators have achieved low dynamic stiffness with large static load capacity. Virgin[3] considered a structure made from a highly deformed elastic element to achieve a softening spring. Platus[4] exploited the buckling of beams under axial load in a specific configuration to achieve a negative stiffness in combination with a positive stiffness, and hence low-dynamic stiffness. Others have achieved the same by connecting linear springs with positive stiffness in parallel with elements of negative stiffness[5] [7]. In the present study, a bifunctional isolator has been developed for optical payloads. The isolator have good performance both during launch and on orbit because of its specially designed nonlinear stiffness and damping. The isolator works in a linear part with low stiffness and small damping ratio under the micro-vibration and microgravity on orbit. The transmissibility requirement and the displacement restriction during launch are satisfied by tuning the nonlinear stiffness and damping parameters. A group of sample isolators are designed tested both statically and dynamically.
Zócalo, Yanina; Curcio, Santiago; García-Espinosa, Victoria; Chiesa, Pedro; Giachetto, Gustavo; Bia, Daniel
2017-12-01
The association between arterial parameters and blood pressure (BP) interindividual variations could depend on the arterial segment, BP component (systolic, SBP; diastolic, DBP; pulse pressure, PP) and/or on whether central (cBP) or peripheral (pBP) BP variations are considered. To assess and compare arterial parameters variations associated with interindividual variations in cBP and pBP. Healthy subjects (n = 923; 488 males, 2-84 years) were included. pBP and cBP waves were obtained (Mobil-O-Graph; SphygmoCor). Arterial diameter, intima-media thickness, local elastic modulus (carotid, CEM; brachial, BEM; femoral, FEM) and regional (carotid-radial and carotid-femoral pulse wave velocity; crPWV and cfPWV) arterial stiffness were determined. Associations between BP and arterial parameters interindividual variations were analyzed and compared (correlations; linear regressions; slopes comparisons) considering data transformed into z-scores. Given a variation in z-cSBP or z-pSBP, z-CEM, z-FEM and z-cfPWV (stiffness indexes), were among the parameters with major BP-associated variations. z-crPWV and z-cfPWV, rather than local stiffness indexes were the parameters with major variations associated with z-DBP variations. z-cPP or z-pPP were associated with z-CEM and z-FEM variations, but not with brachial or regional stiffness variations. Most of the arterial parameters-BP slopes did not show significant differences when considering a variation in z-cSBP and z-pSBP. z-CEM and z-FEM were mainly associated with z-cPP and z-pPP variations, respectively. Disregard of age and sex, the variations in arterial parameters associated with BP interindividual variations showed differences depending on whether variations were central or peripheral; in SBP, DBP or PP and depending on the arterial segment considered.
DOT National Transportation Integrated Search
2005-11-01
The stiffness (elastic modulus and shear modulus) and Poissons ratio of the base and : sublayers are important parameters in the design and quality assurance during construction of : highway pavements. During and after the construction of a paveme...
Dynamic properties of unbonded, multi-strand beams subjected to flexural loading
NASA Astrophysics Data System (ADS)
Asker, Haval K.; Rongong, Jem A.; Lord, Charles E.
2018-02-01
Beam-like structures, constructed from many long strands that are constrained rather than bonded together, can provide appreciable levels of structural damping through friction between individual strands. This paper describes experimental and numerical studies, carried out on square-section metal beams, which are aimed at improving understanding of the relationship between construction and performance. A beam is formed from a pack of square-section strands that is held together at various compression loads with pre-calibrated clamps. Flexural deformation of the assembled beam is simulated using standard finite element analysis employing simple Coulomb friction at the interfaces. The validity of the assumptions used in the models is confirmed by comparison with three point bend tests on a regular nine strand construction at several different clamp loads. Dynamic loss factors for this beam are obtained by conducting forced vibration tests, which show that the damping is insensitive to frequency. Subsequent numerical studies are used to investigate the effects of increasing the number of strands whilst maintaining the overall cross-section geometry of the beam. It is found that the system stiffness drops and loss factor increases when more strands are used for a maintained beam cross-section. Interestingly, the energy dissipated by each beam construction is almost the same. These results provide a vital and necessary insight into the physics for stranded structures and materials that are largely prevalent in mechanical (e.g. cables) and electrical (e.g. wires) elements.
Graupner, Nina; Labonte, David; Humburg, Heide; Buzkan, Tayfun; Dörgens, Anna; Kelterer, Wiebke; Müssig, Jörg
2017-02-28
Here we investigate the mechanical properties and structural design of the pericarp of the green coconut (Cocos nucifera L.). The pericarp showed excellent impact characteristics, and mechanical tests of its individual components revealed gradients in stiffness, strength and elongation at break from the outer to the inner layer of the pericarp. In order to understand more about the potential effect of such gradients on 'bulk' material properties, we designed simple, graded, cellulose fibre-reinforced polylactide (PLA) composites by stacking layers reinforced with fibres of different mechanical properties. Tensile properties of the graded composites were largely determined by the 'weakest' fibre, irrespective of the fibre distribution. However, a graded design led to pronounced asymmetric bending and impact properties. Bio-inspired, asymmetrically graded composites showed a flexural strength and modulus comparable to that of the strongest reference samples, but the elongation at maximum load was dependent on the specimen orientation. The impact strength of the graded composites showed a similar orientation-dependence, and peak values exceeded the impact strength of a non-graded reference composite containing identical fibre fractions by up to a factor of three. In combination, our results show that an asymmetric, systematic variation of fibre properties can successfully combine desirable properties of different fibre types, suggesting new routes for the development of high-performance composites, and improving our understanding of the structure-function relationship of the coconut pericarp.
NASA Technical Reports Server (NTRS)
Smith, R. C.; Bowers, K. L.
1991-01-01
A fully Sinc-Galerkin method for recovering the spatially varying stiffness and damping parameters in Euler-Bernoulli beam models is presented. The forward problems are discretized with a sinc basis in both the spatial and temporal domains thus yielding an approximate solution which converges exponentially and is valid on the infinite time interval. Hence the method avoids the time-stepping which is characteristic of many of the forward schemes which are used in parameter recovery algorithms. Tikhonov regularization is used to stabilize the resulting inverse problem, and the L-curve method for determining an appropriate value of the regularization parameter is briefly discussed. Numerical examples are given which demonstrate the applicability of the method for both individual and simultaneous recovery of the material parameters.
Grosset, Jean-François; Lapole, Thomas; Mora, Isabelle; Verhaeghe, Martine; Doutrellot, Pierre-Louis; Pérot, Chantal
2010-08-01
Clinical manual tests refer to increased ankle stiffness in children immobilized due to hip osteochondritis. The aim of the present study was to investigate musculo-articular stiffness via different techniques in immobilized children to confirm or not and quantify these observations. Ankle stiffness was quantified monthly during the long immobilization period in three diseased children and compared to healthy age-matched children. Sinusoidal perturbations were used to evaluate musculo-articular (MA) stiffness of the ankle plantar-flexors. The stiffness index (SI(MA-EMG)) was the slope of the linear relationship between angular stiffness and plantar-flexion torque normalized with electromyographic activity of the triceps surae (TS). The stiffness of the ankle plantar-flexors was also indirectly evaluated using the TS electromechanical delay (EMD). SI(MA-EMG) was greater for diseased children, and this higher stiffness was confirmed by the higher EMD values found in these immobilized children. Furthermore, both parameters indicated that ankle stiffness continues to increase through immobilization period. This study gives a quantitative evaluation of ankle stiffness changes through the immobilization period imposed to children treated for hip osteochondritis. The use of EMD measurement to indirectly evaluate these stiffness changes is also validated. This study shed for the first time some light into the patterns of muscle modifications following immobilization in children. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
Parametric instability of spinning elastic rings excited by fluctuating space-fixed stiffnesses
NASA Astrophysics Data System (ADS)
Liu, Chunguang; Cooley, Christopher G.; Parker, Robert G.
2017-07-01
This study investigates the vibration of rotating elastic rings that are dynamically excited by an arbitrary number of space-fixed discrete stiffnesses with periodically fluctuating stiffnesses. The rotating, elastic ring is modeled using thin-ring theory with radial and tangential deformations. Primary and combination instability regions are determined in closed-form using the method of multiple scales. The ratio of peak-to-peak fluctuation to average discrete stiffness is used as the perturbation parameter, so the resulting perturbation analysis is not limited to small mean values of discrete stiffnesses. The natural frequencies and vibration modes are determined by discretizing the governing equations using Galerkin's method. Results are demonstrated for compliant gear applications. The perturbation results are validated by direct numerical integration of the equations of motion and Floquet theory. The bandwidths of the instability regions correlate with the fractional strain energy stored in the discrete stiffnesses. For rings with multiple discrete stiffnesses, the phase differences between them can eliminate large amplitude response under certain conditions.
Identification of a parametric, discrete-time model of ankle stiffness.
Guarin, Diego L; Jalaleddini, Kian; Kearney, Robert E
2013-01-01
Dynamic ankle joint stiffness defines the relationship between the position of the ankle and the torque acting about it and can be separated into intrinsic and reflex components. Under stationary conditions, intrinsic stiffness can described by a linear second order system while reflex stiffness is described by Hammerstein system whose input is delayed velocity. Given that reflex and intrinsic torque cannot be measured separately, there has been much interest in the development of system identification techniques to separate them analytically. To date, most methods have been nonparametric and as a result there is no direct link between the estimated parameters and those of the stiffness model. This paper presents a novel algorithm for identification of a discrete-time model of ankle stiffness. Through simulations we show that the algorithm gives unbiased results even in the presence of large, non-white noise. Application of the method to experimental data demonstrates that it produces results consistent with previous findings.
Investigation of the torsional stiffness of flexible disc coupling
NASA Astrophysics Data System (ADS)
Buryy, A.; Simonovsky, V.; Obolonik, V.
2017-08-01
Calculation of flexible coupling torsional stiffness is required when analyzing the torsional vibrations of the reciprocating machinery train. While having the lowest torsional stiffness of all the elements of the train, flexible coupling has a significant influence on the natural frequencies of torsional vibration. However, considering structural complexity of coupling, precise definition of its torsional stiffness is quite a difficult task. The paper presents a method for calculating the torsional stiffness of flexible disc coupling based on the study of its finite element model response under the action of torque. The analysis of the basic parameters that quantitatively and qualitatively affect the coupling torsional stiffness has been also provided. The results of the calculation as well as model adequacy, sufficient for practical application, have been confirmed at the experimental measurement of flexible disc coupling torsional stiffness. The obtained elastic characteristics (dependences of applied torque and torsional stiffness versus twist angle) are nonlinear in the initial stage of loading. This feature should be taken into account when creating reliable mathematical models of torsional vibrations of reciprocating machinery trains containing flexible disc couplings.
van der Feen, Cathelijne; van der Doef, Hubert P J; van der Ent, Cornelis K; Houwen, Roderick H J
2016-11-01
Ursodeoxycholic acid (UDCA) might prevent progression of cystic fibrosis liver disease, but objective parameters for its effect are lacking. We used liver stiffness measurements to evaluate the effect of Ursodeoxycholic acid. Paired measurements of liver stiffness were done in 73 patients without UDCA and in 32 patients with UDCA. In the latter group, 6 patients had cirrhosis; in 15 patients, UDCA was started based on Colombo criteria, and in 11 patients for other reasons. In patients without UDCA, liver stiffness increased: 0.19 (-0.03 to 0.59)kPa/year. Liver stiffness also increased in patients with cirrhosis: 4.6 (0.67-12.4)kPa/year. In patients who had UDCA based on Colombo criteria, a decrease of liver stiffness was observed: 0.70 (-1.6 to 0.55)kPa/year (P=0.01). In patients on UDCA for other reasons, liver stiffness increased: 0.23 (-0.20 to 0.51)kPa/year. UDCA reduced liver stiffness in patients with well-defined, mild liver disease. Copyright © 2016 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Wang, G; Wu, K; Hu, H; Li, G; Wang, L J
2016-10-01
To reduce seismic and environmental vibration noise, ultra-low-frequency vertical vibration isolation systems play an important role in absolute gravimetry. For this purpose, an isolator based on a two-stage beam structure is proposed and demonstrated. The isolator has a simpler and more robust structure than the present ultra-low-frequency vertical active vibration isolators. In the system, two beams are connected to a frame using flexural pivots. The upper beam is suspended from the frame with a normal hex spring and the lower beam is suspended from the upper one using a zero-length spring. The pivot of the upper beam is not vertically above the pivot of the lower beam. With this special design, the attachment points of the zero-length spring to the beams can be moved to adjust the effective stiffness. A photoelectric detector is used to detect the angle between the two beams, and a voice coil actuator attached to the upper beam is controlled by a feedback circuit to keep the angle at a fixed value. The system can achieve a natural period of 100 s by carefully moving the attachment points of the zero-length spring to the beams and tuning the feedback parameters. The system has been used as an inertial reference in the T-1 absolute gravimeter. The experiment results demonstrate that the system has significant vibration isolation performance that holds promise in applications such as absolute gravimeters.
NASA Astrophysics Data System (ADS)
Wang, G.; Wu, K.; Hu, H.; Li, G.; Wang, L. J.
2016-10-01
To reduce seismic and environmental vibration noise, ultra-low-frequency vertical vibration isolation systems play an important role in absolute gravimetry. For this purpose, an isolator based on a two-stage beam structure is proposed and demonstrated. The isolator has a simpler and more robust structure than the present ultra-low-frequency vertical active vibration isolators. In the system, two beams are connected to a frame using flexural pivots. The upper beam is suspended from the frame with a normal hex spring and the lower beam is suspended from the upper one using a zero-length spring. The pivot of the upper beam is not vertically above the pivot of the lower beam. With this special design, the attachment points of the zero-length spring to the beams can be moved to adjust the effective stiffness. A photoelectric detector is used to detect the angle between the two beams, and a voice coil actuator attached to the upper beam is controlled by a feedback circuit to keep the angle at a fixed value. The system can achieve a natural period of 100 s by carefully moving the attachment points of the zero-length spring to the beams and tuning the feedback parameters. The system has been used as an inertial reference in the T-1 absolute gravimeter. The experiment results demonstrate that the system has significant vibration isolation performance that holds promise in applications such as absolute gravimeters.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., means the maximum breadth of the ship, measured amidships to the moulded line of the frame in a ship... with no openings. (r) Steel means steel and materials with which structures can be made equivalent to steel with respect to such parameters as yield strength, total deflection, flexural life, or resistance...
Code of Federal Regulations, 2011 CFR
2011-10-01
..., means the maximum breadth of the ship, measured amidships to the moulded line of the frame in a ship... with no openings. (r) Steel means steel and materials with which structures can be made equivalent to steel with respect to such parameters as yield strength, total deflection, flexural life, or resistance...
[Vascular aging, arterial hypertension and physical activity].
Schmidt-Trucksäss, A; Weisser, B
2011-11-01
The present review delineates the significance of intima-media-thickness, arterial stiffness and endothelial function for vascular aging. There is profound evidence for an increase in intima-media-thickness and vascular stiffness not only during healthy aging but induced also by cardiovascular risk factors. There is a central role of arterial hypertension for this progression in both structural factors. In addition, both parameters are strongly associated with cardiovascular risk. Endothelial function measured as postischemic flow-mediated vasodilatation is a functional parameter which is decreased both in healthy aging and by cardiovascular risk factors. Physical activity modifies the influence of aging and risk factors on endothelial function. A positive influence of endurance exercise on vascular stiffness and endothelial function has been demonstrated in numerous studies. In long-term studies, regular physical activity has been shown to reduce the progression of intima-media-thickness. Thus, arterial hypertension accelerates vascular aging, while physical activity has a positive influence on a variety of vascular parameters associated with vascular aging. © Georg Thieme Verlag KG Stuttgart · New York.
Simulation of car collision with an impact block
NASA Astrophysics Data System (ADS)
Kostek, R.; Aleksandrowicz, P.
2017-10-01
This article presents the experimental results of crash test of Fiat Cinquecento performed by Allgemeiner Deutscher Automobil-Club (ADAC) and the simulation results obtained with program called V-SIM for default settings. At the next stage a wheel was blocked and the parameters of contact between the vehicle and the barrier were changed for better results matching. The following contact parameters were identified: stiffness at compression phase, stiffness at restitution phase, the coefficients of restitution and friction. The changes lead to various post-impact positions, which shows sensitivity of the results to contact parameters. V-SIM is commonly used by expert witnesses who tend to use default settings, therefore the companies offering simulation programs should identify those parameters with due diligence.
Dynamic characteristics of a vibrating beam with periodic variation in bending stiffness
NASA Technical Reports Server (NTRS)
Townsend, John S.
1987-01-01
A detailed dynamic analysis is performed of a vibrating beam with bending stiffness periodic in the spatial coordinate. Using a perturbation expansion technique the free vibration solution is obtained in a closed-form, and the effects of system parameters on beam response are explored. It is found that periodic stiffness acts to modulate the modal displacements from the characteristic shape of a simple sine wave. The results are verified by a finite element solution and through experimental testing.
Fuzzy variable impedance control based on stiffness identification for human-robot cooperation
NASA Astrophysics Data System (ADS)
Mao, Dachao; Yang, Wenlong; Du, Zhijiang
2017-06-01
This paper presents a dynamic fuzzy variable impedance control algorithm for human-robot cooperation. In order to estimate the intention of human for co-manipulation, a fuzzy inference system is set up to adjust the impedance parameter. Aiming at regulating the output fuzzy universe based on the human arm’s stiffness, an online stiffness identification method is developed. A drag interaction task is conducted on a 5-DOF robot with variable impedance control. Experimental results demonstrate that the proposed algorithm is superior.
Evaluation of Eco-Efficiency and Performance of Retrofit Materials
NASA Astrophysics Data System (ADS)
Gopinath, Smitha; Rama Chandra Murthy, A.; Iyer, Nagesh R.; Kokila, S.
2015-12-01
In this work three materials namely Fiber Reinforced Polymer (FRP), ferrocement and Textile Reinforced Concrete (TRC) have been evaluated towards their performance efficiency and eco-effectiveness for sustainable retrofitting applications. Investigations have been carried out for flexural strengthening of RC beams with FRP, ferrocement and TRC. It is observed that in the case of FRP, it is not possible to tailor the material according to design requirements and most of the time strengthened structure becomes over stiff. Eco-effectiveness of these retrofitting materials has been evaluated by computing the embodied energy. It is observed that the amount of CO2 emitted by TRC is less compared to other retrofit materials. Further, the performance point of retrofitted RC frames has been evaluated and damage index has been calculated to find out the effective retrofit material. It is concluded that, if RC frame is retrofitted with FRP and TRC, it undergoes less damage compared to ferrocement.
High renewable content sandwich structures based on flax-basalt hybrids and biobased epoxy polymers
NASA Astrophysics Data System (ADS)
Colomina, S.; Boronat, T.; Fenollar, O.; Sánchez-Nacher, L.; Balart, R.
2014-05-01
In the last years, a growing interest in the development of high environmental efficiency materials has been detected and this situation is more accentuated in the field of polymers and polymer composites. In this work, green composite sandwich structures with high renewable content have been developed with core cork materials. The base resin for composites was a biobased epoxy resin derived from epoxidized vegetable oils. Hybrid basalt-flax fabrics have been used as reinforcements for composites and the influence of the stacking sequence has been evaluated in order to optimize the appropriate laminate structure for the sandwich bases. Core cork materials with different thickness have been used to evaluate performance of sandwich structures thus leading to high renewable content composite sandwich structures. Results show that position of basalt fabrics plays a key role in flexural fracture of sandwich structures due to differences in stiffness between flax and basalt fibers.
Leonard, Ryan J; McArthur, Clare; Hochuli, Dieter F
2016-08-01
Plants are routinely subjected to multiple environmental stressors, and the ability to respond to these stressors determines species survival and ecological breadth. Despite stressors such as wind and dust significantly influencing plant development, morphology, and chemistry, the combined influence of these factors is yet to be investigated. We used a manipulative glasshouse approach to compare the morphological, physiological, and biomechanical responses of Eucalyptus tereticornis to the independent and combined effects of wind and dust. Wind decreased both E. tereticornis height and stem flexural stiffness. Additionally, wind had no effect on leaf physiology, nor did dust have any significant effect on any of the traits measured. Our results suggest that wind and dust in combination may have an additive effect on several plant traits and provide new insight into the effects and importance of studying wind, dust, and different stress combinations. © 2016 Botanical Society of America.
Strength Development of High-Strength Ductile Concrete Incorporating Metakaolin and PVA Fibers
Nuruddin, Muhammad Fadhil; Shafiq, Nasir
2014-01-01
The mechanical properties of high-strength ductile concrete (HSDC) have been investigated using Metakaolin (MK) as the cement replacing material and PVA fibers. Total twenty-seven (27) mixes of concrete have been examined with varying content of MK and PVA fibers. It has been found that the coarser type PVA fibers provide strengths competitive to control or higher than control. Concrete with coarser type PVA fibers has also refined microstructure, but the microstructure has been undergone with the increase in aspect ratio of fibers. The microstructure of concrete with MK has also more refined and packing of material is much better with MK. PVA fibers not only give higher stiffness but also showed the deflection hardening response. Toughness Index of HSDC reflects the improvement in flexural toughness over the plain concrete and the maximum toughness indices have been observed with 10% MK and 2% volume fraction of PVA fibers. PMID:24707202
Strength development of high-strength ductile concrete incorporating Metakaolin and PVA fibers.
Nuruddin, Muhammad Fadhil; Khan, Sadaqat Ullah; Shafiq, Nasir; Ayub, Tehmina
2014-01-01
The mechanical properties of high-strength ductile concrete (HSDC) have been investigated using Metakaolin (MK) as the cement replacing material and PVA fibers. Total twenty-seven (27) mixes of concrete have been examined with varying content of MK and PVA fibers. It has been found that the coarser type PVA fibers provide strengths competitive to control or higher than control. Concrete with coarser type PVA fibers has also refined microstructure, but the microstructure has been undergone with the increase in aspect ratio of fibers. The microstructure of concrete with MK has also more refined and packing of material is much better with MK. PVA fibers not only give higher stiffness but also showed the deflection hardening response. Toughness Index of HSDC reflects the improvement in flexural toughness over the plain concrete and the maximum toughness indices have been observed with 10% MK and 2% volume fraction of PVA fibers.
Flow-structure Interaction Modeling of a Fish Caudal Fin during Steady Swimming
NASA Astrophysics Data System (ADS)
Liu, Geng; Geng, Biao; Zheng, Xudong; Xue, Qian; Dong, Haibo
2017-11-01
It's widely thought that the flexibilities of fish fins play critical roles in propulsive performance enhancement (such as thrust augment and efficiency improvement) in nature. In order to explore the formation mechanisms of the fish fin's flexible morphing and its hydrodynamic benefits as well, a high-fidelity flow-structure/membrane interaction modeling of the fish caudal fin is conducted in this work. Following the realistic configuration of the fish caudal fin, a thin membrane supported by a series of beams is constructed. The material properties of the membrane and the beams are reversely determined by the realistic fin morphing obtained from the high-speed videos and the high fidelity flow-structure interaction simulations. With the accurate material property, we investigate the interplay between structure, kinematics and fluid flow in caudal fin propulsion. Detailed analyses on the relationship between the flexural stiffness, fin morphing patterns, hydrodynamic forces and vortex dynamics are then conducted.
NASA Technical Reports Server (NTRS)
Bainum, P. M.; James, P. K.
1977-01-01
The dynamics of a spinning symmetrical spacecraft system during the deployment (or retraction) of flexible boom-type appendages were investigated. The effect of flexibility during boom deployment is treated by modelling the deployable members as compound spherical pendula of varying length (according to a control law). The orientation of the flexible booms with respect to the hub, is described by a sequence of two Euler angles. The boom members contain a flexural stiffness which can be related to an assumed effective restoring linear spring constant, and structural damping which effects the entire system. Linearized equations of motion for this system, when the boom length is constant, involve periodic coefficients with the frequency of the hub spin. A bounded transformation is found which converts this system into a kinematically equivalent one involving only constant coefficients.
Strengthing of Beams and Columns using GFRP Bars
NASA Astrophysics Data System (ADS)
Nayak, C. B.; Tade, M. K.; Thakare, S. B., Dr.
2017-08-01
Nowadays infrastructure development is raising its pace. Many reinforced high concrete and masonry buildings are constructed annually around the globe. There are large numbers of structures which deteriorate or become unsafe to use because of changes in use, changes in loading condition, change in the design configuration, inferior building material used or natural calamities. Thus repairing and retrofitting of these structures for safe usage of has a great market. There are several situations in which a civil structure would require strengthening due to lack of strength, stiffness, ductility and durability. Beams, columns may be strengthened in flexure by using GFRP in tension zone. In this present work comparative study will be made with and without GFRP circular bars in a beam and column. An experiment study will be carried out to study the change in the structural behavior of beams & columns with GFRP circular bars of different thickness, varying span to depth ratio.
Grau, L; Laulagnet, B
2015-05-01
An analytical approach is investigated to model ground-plate interaction based on modal decomposition and the two-dimensional Fourier transform. A finite rectangular plate subjected to flexural vibration is coupled with the ground and modeled with the Kirchhoff hypothesis. A Navier equation represents the stratified ground, assumed infinite in the x- and y-directions and free at the top surface. To obtain an analytical solution, modal decomposition is applied to the structure and a Fourier Transform is applied to the ground. The result is a new tool for analyzing ground-plate interaction to resolve this problem: ground cross-modal impedance. It allows quantifying the added-stiffness, added-mass, and added-damping from the ground to the structure. Similarity with the parallel acoustic problem is highlighted. A comparison between the theory and the experiment shows good matching. Finally, specific cases are investigated, notably the influence of layer depth on plate vibration.
Improved Subcell Model for the Prediction of Braided Composite Response
NASA Technical Reports Server (NTRS)
Cater, Christopher R.; Xinran, Xiao; Goldberg, Robert K.; Kohlman, Lee W.
2013-01-01
In this work, the modeling of triaxially braided composites was explored through a semi-analytical discretization. Four unique subcells, each approximated by a "mosaic" stacking of unidirectional composite plies, were modeled through the use of layered-shell elements within the explicit finite element code LS-DYNA. Two subcell discretizations were investigated: a model explicitly capturing pure matrix regions, and a novel model which absorbed pure matrix pockets into neighboring tow plies. The in-plane stiffness properties of both models, computed using bottom-up micromechanics, correlated well to experimental data. The absorbed matrix model, however, was found to best capture out-of- plane flexural properties by comparing numerical simulations of the out-of-plane displacements from single-ply tension tests to experimental full field data. This strong correlation of out-of-plane characteristics supports the current modeling approach as a viable candidate for future work involving impact simulations.
Höppner, Hannes; Große-Dunker, Maximilian; Stillfried, Georg; Bayer, Justin; van der Smagt, Patrick
2017-01-01
We investigate the relation between grip force and grip stiffness for the human hand with and without voluntary cocontraction. Apart from gaining biomechanical insight, this issue is particularly relevant for variable-stiffness robotic systems, which can independently control the two parameters, but for which no clear methods exist to design or efficiently exploit them. Subjects were asked in one task to produce different levels of force, and stiffness was measured. As expected, this task reveals a linear coupling between force and stiffness. In a second task, subjects were then asked to additionally decouple stiffness from force at these force levels by using cocontraction. We measured the electromyogram from relevant groups of muscles and analyzed the possibility to predict stiffness and force. Optical tracking was used for avoiding wrist movements. We found that subjects were able to decouple grip stiffness from force when using cocontraction on average by about 20% of the maximum measured stiffness over all force levels, while this ability increased with the applied force. This result contradicts the force–stiffness behavior of most variable-stiffness actuators. Moreover, we found the thumb to be on average twice as stiff as the index finger and discovered that intrinsic hand muscles predominate our prediction of stiffness, but not of force. EMG activity and grip force allowed to explain 72 ± 12% of the measured variance in stiffness by simple linear regression, while only 33 ± 18% variance in force. Conclusively the high signal-to-noise ratio and the high correlation to stiffness of these muscles allow for a robust and reliable regression of stiffness, which can be used to continuously teleoperate compliance of modern robotic hands. PMID:28588472
A Sensitivity Analysis of an Inverted Pendulum Balance Control Model.
Pasma, Jantsje H; Boonstra, Tjitske A; van Kordelaar, Joost; Spyropoulou, Vasiliki V; Schouten, Alfred C
2017-01-01
Balance control models are used to describe balance behavior in health and disease. We identified the unique contribution and relative importance of each parameter of a commonly used balance control model, the Independent Channel (IC) model, to identify which parameters are crucial to describe balance behavior. The balance behavior was expressed by transfer functions (TFs), representing the relationship between sensory perturbations and body sway as a function of frequency, in terms of amplitude (i.e., magnitude) and timing (i.e., phase). The model included an inverted pendulum controlled by a neuromuscular system, described by several parameters. Local sensitivity of each parameter was determined for both the magnitude and phase using partial derivatives. Both the intrinsic stiffness and proportional gain shape the magnitude at low frequencies (0.1-1 Hz). The derivative gain shapes the peak and slope of the magnitude between 0.5 and 0.9 Hz. The sensory weight influences the overall magnitude, and does not have any effect on the phase. The effect of the time delay becomes apparent in the phase above 0.6 Hz. The force feedback parameters and intrinsic stiffness have a small effect compared with the other parameters. All parameters shape the TF magnitude and phase and therefore play a role in the balance behavior. The sensory weight, time delay, derivative gain, and the proportional gain have a unique effect on the TFs, while the force feedback parameters and intrinsic stiffness contribute less. More insight in the unique contribution and relative importance of all parameters shows which parameters are crucial and critical to identify underlying differences in balance behavior between different patient groups.
Curved PVDF airborne transducer.
Wang, H; Toda, M
1999-01-01
In the application of airborne ultrasonic ranging measurement, a partially cylindrical (curved) PVDF transducer can effectively couple ultrasound into the air and generate strong sound pressure. Because of its geometrical features, the ultrasound beam angles of a curved PVDF transducer can be unsymmetrical (i.e., broad horizontally and narrow vertically). This feature is desired in some applications. In this work, a curved PVDF air transducer is investigated both theoretically and experimentally. Two resonances were observed in this transducer. They are length extensional mode and flexural bending mode. Surface vibration profiles of these two modes were measured by a laser vibrometer. It was found from the experiment that the surface vibration was not uniform along the curvature direction for both vibration modes. Theoretical calculations based on a model developed in this work confirmed the experimental results. Two displacement peaks were found in the piezoelectric active direction of PVDF film for the length extensional mode; three peaks were found for the flexural bending mode. The observed peak positions were in good agreement with the calculation results. Transient surface displacement measurements revealed that vibration peaks were in phase for the length extensional mode and out of phase for the flexural bending mode. Therefore, the length extensional mode can generate a stronger ultrasound wave than the flexural bending mode. The resonance frequencies and vibration amplitudes of the two modes strongly depend on the structure parameters as well as the material properties. For the transducer design, the theoretical model developed in this work can be used to optimize the ultrasound performance.
Helical wire stress analysis of unbonded flexible riser under irregular response
NASA Astrophysics Data System (ADS)
Wang, Kunpeng; Ji, Chunyan
2017-06-01
A helical wire is a critical component of an unbonded flexible riser prone to fatigue failure. The helical wire has been the focus of much research work in recent years because of the complex multilayer construction of the flexible riser. The present study establishes an analytical model for the axisymmetric and bending analyses of an unbonded flexible riser. The interlayer contact under axisymmetric loads in this model is modeled by setting radial dummy springs between adjacent layers. The contact pressure is constant during the bending response and applied to determine the slipping friction force per unit helical wire. The model tracks the axial stress around the angular position at each time step to calculate the axial force gradient, then compares the axial force gradient with the slipping friction force to judge the helical wire slipping region, which would be applied to determine the bending stiffness for the next time step. The proposed model is verified against the experimental data in the literature. The bending moment-curvature relationship under irregular response is also qualitatively discussed. The stress at the critical point of the helical wire is investigated based on the model by considering the local flexure. The results indicate that the present model can well simulate the bending stiffness variation during irregular response, which has significant effect on the stress of helical wire.
Vertical electrostatic actuator with extended digital range via tailored topology
NASA Astrophysics Data System (ADS)
Zhang, Yanhang; Dunn, Martin L.
2002-07-01
We describe the design, fabrication, and testing of an electrostatic vertical actuator that exhibits a range of motion that covers the entire initial gap between the actuator and substrate and provides controllable digital output motion. This is obtained by spatially tailoring the electrode arrangement and the stiffness characteristics of the microstructure to control the voltage-deflection characteristics. The concept is based on the electrostatic pull down of bimaterial beams, via a series of electrodes attached to the beams by flexures with tailored stiffness characteristics. The range of travel of the actuator is defined by the post-release deformed shape of the bilayer beams, and can be controlled by a post-release heat-treat process combined with a tailored actuator topology (material distribution and geometry, including spatial geometrical patterning of the individual layers of the bilayer beams). Not only does this allow an increase in the range of travel to cover the entire initial gap, but it also permits digital control of the tip of the actuator which can be designed to yield linear displacement - pull in step characteristics. We fabricated these actuators using the MUMPs surface micromachining process, and packaged them in-house. We measured, using an interferometric microscope, full field deformed shapes of the actuator at each pull in step. The measurements compare well with companion simulation results, both qualitatively and quantitatively.
Resonant Column Tests and Nonlinear Elasticity in Simulated Rocks
NASA Astrophysics Data System (ADS)
Sebastian, Resmi; Sitharam, T. G.
2018-01-01
Rocks are generally regarded as linearly elastic even though the manifestations of nonlinearity are prominent. The variations of elastic constants with varying strain levels and stress conditions, disagreement between static and dynamic moduli, etc., are some of the examples of nonlinear elasticity in rocks. The grain-to-grain contact, presence of pores and joints along with other compliant features induce the nonlinear behavior in rocks. The nonlinear elastic behavior of rocks is demonstrated through resonant column tests and numerical simulations in this paper. Resonant column tests on intact and jointed gypsum samples across varying strain levels have been performed in laboratory and using numerical simulations. The paper shows the application of resonant column apparatus to obtain the wave velocities of stiff samples at various strain levels under long wavelength condition, after performing checks and incorporating corrections to the obtained resonant frequencies. The numerical simulation and validation of the resonant column tests using distinct element method are presented. The stiffness reductions of testing samples under torsional and flexural vibrations with increasing strain levels have been analyzed. The nonlinear elastic behavior of rocks is reflected in the results, which is enhanced by the presence of joints. The significance of joint orientation and influence of joint spacing during wave propagation have also been assessed and presented using the numerical simulations. It has been found that rock joints also exhibit nonlinear behavior within the elastic limit.
NASA Astrophysics Data System (ADS)
Karyadi, Susanto, Prijono Bagus
2017-09-01
A box-section beam has a larger moment of inertia than solid beam for the same amount of materials, so, it is expected the box-section beams has larger strength and stiffness compared to the solid beam. In other hand, research about the box-section beams, especially from bamboo lamination material, is limited. For the reason the research was done. The research aimed at finding mechanical characteristic of box-section beams made of sliced-laminated Asian bamboo in bending failure mode under transversal load. The results showed that the strength and stiffness of the box-section beams increase according to the increasing moment of inertia. The strength of the box-section beam increase up to ratio between the section height (h) and section width (b) reach 1.50. Larger than the ratio the strength of the beam will decrease. The average of bending stress at the time of beam collapse reached 106.5MPa and the average of flexural of elastic modulus reached 14.504MPa. The serviceability load reached 8.64% of the maximum load. Based on the results it can be concluded that the box-section beams made of sliced-laminated Asian bamboo more efficient in receiving the transversal load compared to the solid beam for the same amount of materials.
Modeling the Flexural Rigidity of Rod Photoreceptors
Haeri, Mohammad; Knox, Barry E.; Ahmadi, Aphrodite
2013-01-01
In vertebrate eyes, the rod photoreceptor has a modified cilium with an extended cylindrical structure specialized for phototransduction called the outer segment (OS). The OS has numerous stacked membrane disks and can bend or break when subjected to mechanical forces. The OS exhibits axial structural variation, with extended bands composed of a few hundred membrane disks whose thickness is diurnally modulated. Using high-resolution confocal microscopy, we have observed OS flexing and disruption in live transgenic Xenopus rods. Based on the experimental observations, we introduce a coarse-grained model of OS mechanical rigidity using elasticity theory, representing the axial OS banding explicitly via a spring-bead model. We calculate a bending stiffness of ∼105 nN⋅μm2, which is seven orders-of-magnitude larger than that of typical cilia and flagella. This bending stiffness has a quadratic relation to OS radius, so that thinner OS have lower fragility. Furthermore, we find that increasing the spatial frequency of axial OS banding decreases OS rigidity, reducing its fragility. Moreover, the model predicts a tendency for OS to break in bands with higher spring number density, analogous to the experimental observation that transgenic rods tended to break preferentially in bands of high fluorescence. We discuss how pathological alterations of disk membrane properties by mutant proteins may lead to increased OS rigidity and thus increased breakage, ultimately contributing to retinal degeneration. PMID:23442852
Acoustic and elastic waves in metamaterials for underwater applications
NASA Astrophysics Data System (ADS)
Titovich, Alexey S.
Elastic effects in acoustic metamaterials are investigated. Water-based periodic arrays of elastic scatterers, sonic crystals, suffer from low transmission due to the impedance and index mismatch of typical engineering materials with water. A new type of acoustic metamaterial element is proposed that can be tuned to match the acoustic properties of water in the quasi-static regime. The element comprises a hollow elastic cylindrical shell fitted with an optimized internal substructure consisting of a central mass supported by an axisymmetric distribution of elastic stiffeners, which dictate the shell's effective bulk modulus and density. The derived closed form scattering solution for this system shows that the subsonic flexural waves excited in the shell by the attachment of stiffeners are suppressed by including a sufficiently large number of such stiffeners. As an example of refraction-based wave steering, a cylindrical-to-plane wave lens is designed by varying the bulk modulus in the array according to the conformal mapping of a unit circle to a square. Elastic shells provide rich scattering properties, mainly due to their ability to support highly dispersive flexural waves. Analysis of flexural-borne waves on a pair of shells yields an analytical expression for the width of a flexural resonance, which is then used with the theory of multiple scattering to accurately predict the splitting of the resonance frequency. This analysis leads to the discovery of the acoustic Poisson-like effect in a periodic wave medium. This effect redirects an incident acoustic wave by 90° in an otherwise acoustically transparent sonic crystal. An unresponsive "deaf" antisymmetric mode locked to band gap boundaries is unlocked by matching Bragg scattering with a quadrupole flexural resonance of the shell. The dynamic effect causes normal unidirectional wave motion to strongly couple to perpendicular motion, analogous to the quasi-static Poisson effect in solids. The Poisson-like effect is demonstrated using the first flexural resonance of an acrylic shell. This represent a new type of material which cannot be accurately described as an effective acoustic medium. The study concludes with an analysis of a non-zero shear modulus in a pentamode cloak via the two-scale method with the shear modulus as the perturbation parameter.
Biomechanical response to ankle-foot orthosis stiffness during running.
Russell Esposito, Elizabeth; Choi, Harmony S; Owens, Johnny G; Blanck, Ryan V; Wilken, Jason M
2015-12-01
The Intrepid Dynamic Exoskeletal Orthosis (IDEO) is an ankle-foot orthosis developed to address the high rates of delayed amputation in the military. Its use has enabled many wounded Service Members to run again. During running, stiffness is thought to influence an orthosis' energy storage and return mechanical properties. This study examined the effect of orthosis stiffness on running biomechanics in patients with lower limb impairments who had undergone unilateral limb salvage. Ten patients with lower limb impairments underwent gait analysis at a self-selected running velocity. 1. Nominal (clinically-prescribed), 2. Stiff (20% stiffer than nominal), and 3. Compliant (20% less stiff than nominal) ankle-foot orthosis stiffnesses were tested. Ankle joint stiffness was greatest in the stiffest strut and lowest in the compliant strut, however ankle mechanical work remained unchanged. Speed, stride length, cycle time, joint angles, moments, powers, and ground reaction forces were not significantly different among stiffness conditions. Ankle joint kinematics and ankle, knee and hip kinetics were different between limbs. Ankle power, in particular, was lower in the injured limb. Ankle-foot orthosis stiffness affected ankle joint stiffness but did not influence other biomechanical parameters of running in individuals with unilateral limb salvage. Foot strike asymmetries may have influenced the kinetics of running. Therefore, a range of stiffness may be clinically appropriate when prescribing ankle-foot orthoses for active individuals with limb salvage. Published by Elsevier Ltd.
Chan, Ka Man Carmen; Li, Randolph H.; Chapman, Joseph W.; Trac, Eric M.; Kobler, James B.; Zeitels, Steven M.; Langer, Robert; Karajanagi, Sandeep S.
2014-01-01
Particle size, stiffness and surface functionality are important in determining the injection site, safety and efficacy of injectable soft-tissue fillers. Methods to produce soft injectable biomaterials with controlled particle characteristics are therefore desirable. Here we report a method based on suspension photopolymerization and semi-interpenetrating network (semi-IPN) to synthesize soft, functionalizable, spherical hydrogel microparticles (MP) of independently tunable size and stiffness. MP were prepared using acrylated forms of polyethylene glycol (PEG), gelatin and hyaluronic acid. Semi-IPN MP of PEG-diacrylate and PEG were used to study the effect of process parameters on particle characteristics. The process parameters were systematically varied to produce MP with size ranging from 115 to 515 μm and stiffness ranging from 190 to 1600 Pa. In vitro studies showed that the MP thus prepared were cytocompatible. The ratio and identity of the polymers used to make the semi-IPN MP were varied to control their stiffness and to introduce amine groups for potential functionalization. Slow-release polymeric particles loaded with Rhodamine or dexamethasone were incorporated in the MP as a proof-of-principle of drug incorporation and release from the MP. This work has implications in preparing injectable biomaterials of natural or synthetic polymers for applications as soft-tissue fillers. PMID:24561708
Metabolic risk factors and arterial stiffness in Indian children of parents with metabolic syndrome.
Khadilkar, Anuradha V; Chiplonkar, Shashi A; Pandit, Deepa S; Kinare, Arun S; Khadilkar, Vaman V
2012-02-01
To investigate the possible association between metabolic syndrome (MS) and arterial stiffness in Indian children with parental MS status. A cross-sectional study was conducted in 140 overweight/obese and 60 normal-weight Indian children (mean age, 11.4 ± 2.8 years) along with one of their parents during 2008-2009. Data on weight, height, blood pressure, serum lipids, zinc, insulin, and glucose were collected. Intima media thickness (CIMT) and stiffness parameters were assessed in the right carotid artery. Physical activity and diet were assessed using structured questionnaires. Body composition was measured using dual-energy x-ray absorptiometry. A gradual increase in the percentage of MS children with an increasing number of MS components in parents was observed. Mean values for arterial stiffness, pulse wave velocity, and elastic modulus were significantly higher in MS children of MS parents than in MS children of normal parents (p < 0.05). A significant correlation was observed for lifestyle, metabolic, and arterial parameters among child-parent pairs (p < 0.05). Multiple logistic regression revealed that children's CIMT and arterial stiffness were significantly associated (p < 0.01) with their serum levels of triglycerides, high-density lipoprotein, and zinc, as well as with parental MS-CIMT. Parental MS status and lifestyle factors increase the risk of MS and arterial abnormalities in children.
Reliability of Leg and Vertical Stiffness During High Speed Treadmill Running.
Pappas, Panagiotis; Dallas, Giorgos; Paradisis, Giorgos
2017-04-01
In research, the accurate and reliable measurement of leg and vertical stiffness could contribute to valid interpretations. The current study aimed at determining the intraparticipant variability (ie, intraday and interday reliabilities) of leg and vertical stiffness, as well as related parameters, during high speed treadmill running, using the "sine-wave" method. Thirty-one males ran on a treadmill at 6.67 m∙s -1 , and the contact and flight times were measured. To determine the intraday reliability, three 10-s running bouts with 10-min recovery were performed. In addition, to examine the interday reliability, three 10-s running bouts on 3 separate days with 48-h interbout intervals were performed. The reliability statistics included repeated-measure analysis of variance, average intertrial correlations, intraclass correlation coefficients (ICCs), Cronbach's α reliability coefficient, and the coefficient of variation (CV%). Both intraday and interday reliabilities were high for leg and vertical stiffness (ICC > 0.939 and CV < 4.3%), as well as related variables (ICC > 0.934 and CV < 3.9%). It was thus inferred that the measurements of leg and vertical stiffness, as well as the related parameters obtained using the "sine-wave" method during treadmill running at 6.67 m∙s -1 , were highly reliable, both within and across days.
An MRF-based device for the torque stiffness control of all movable vertical tails
NASA Astrophysics Data System (ADS)
Ameduri, Salvatore; Concilio, Antonio; Gianvito, Antonio; Lemme, Manuel
2005-05-01
Aerodynamic control surfaces efficiency is among the major parameters defining the performance of generic aircraft and is strongly affected by geometric and stiffness characteristics. A target of the '3AS' European Project is to estimate the eventual benefits coming from the adaptive control of the torque rigidity of the vertical tail of the EuRAM wind tunnel model. The specific role of CIRA inside the Project is the design of a device based on the "Smart Structures and Materials" concept, able to produce required stiffness variations. Numerical and experimental investigations pointed out that wide excursions of the tail torque rigidity may assure higher efficiency, for several flight regimes. Stiffness variations may be obtained through both classical mechanic-hydraulic and smart systems. In this case, the attainable weight and reliability level may be the significant parameters to drive the choice. For this reason, CIRA focused its efforts also on the design of devices without heavy mechanical parts. The device described in this work is schematically constituted by linear springs linked in a suitably way to the tail shaft. Required stiffness variations are achieved by selectively locking one or more springs, through a hydraulic system, MRF-based. An optimisation process was performed to find the spring features maximising the achievable stiffness range. Then, the hydraulic MRF design was dealt with. Finally, basing on numerical predictions, a prototype was manufactured and an experimental campaign was performed to estimate the device static and dynamic behaviour.
Soman, Pranav; Kelber, Jonathan A; Lee, Jin Woo; Wright, Tracy N; Vecchio, Kenneth S; Klemke, Richard L; Chen, Shaochen
2012-10-01
Our current understanding of 3-dimensional (3D) cell migration is primarily based on results from fibrous scaffolds with randomly organized internal architecture. Manipulations that change the stiffness of these 3D scaffolds often alter other matrix parameters that can modulate cell motility independently or synergistically, making observations less predictive of how cells behave when migrating in 3D. In order to decouple microstructural influences and stiffness effects, we have designed and fabricated 3D polyethylene glycol (PEG) scaffolds that permit orthogonal tuning of both elastic moduli and microstructure. Scaffolds with log-pile architectures were used to compare the 3D migration properties of normal breast epithelial cells (HMLE) and Twist-transformed cells (HMLET). Our results indicate that the nature of cell migration is significantly impacted by the ability of cells to migrate in the third dimension. 2D ECM-coated PEG substrates revealed no statistically significant difference in cell migration between HMLE and HMLET cells among substrates of different stiffness. However, when cells were allowed to move along the third dimension, substantial differences were observed for cell displacement, velocity and path straightness parameters. Furthermore, these differences were sensitive to both substrate stiffness and the presence of the Twist oncogene. Importantly, these 3D modes of migration provide insight into the potential for oncogene-transformed cells to migrate within and colonize tissues of varying stiffness. Copyright © 2012 Elsevier Ltd. All rights reserved.
Subject-specific left ventricular dysfunction modeling using composite material mechanics approach
NASA Astrophysics Data System (ADS)
Haddad, Seyed Mohammad Hassan; Karami, Elham; Samani, Abbas
2017-03-01
Diverse cardiac conditions such as myocardial infarction and hypertension can lead to diastolic dysfunction as a prevalent cardiac condition. Diastolic dysfunctions can be diagnosed through different adverse mechanisms such as abnormal left ventricle (LV) relaxation, filling, and diastolic stiffness. This paper is geared towards evaluating diastolic stiffness and measuring the LV blood pressure non-invasively. Diastolic stiffness is an important parameter which can be exploited for more accurate diagnosis of diastolic dysfunction. For this purpose, a finite element (FE) LV mechanical model, which works based on a novel composite material model of the cardiac tissue, was utilized. Here, this model was tested for inversion-based applications where it was applied for estimating the cardiac tissue passive stiffness mechanical properties as well as diastolic LV blood pressure. To this end, the model was applied to simulate diastolic inflation of the human LV. The start-diastolic LV geometry was obtained from MR image data segmentation of a healthy human volunteer. The obtained LV geometry was discretized into a FE mesh before FE simulation was conducted. The LV tissue stiffness and diastolic LV blood pressure were adjusted through optimization to achieve the best match between the calculated LV geometry and the one obtained from imaging data. The performance of the LV mechanical simulations using the optimal values of tissue stiffness and blood pressure was validated by comparing the geometrical parameters of the dilated LV model as well as the stress and strain distributions through the LV model with available measurements reported on the LV dilation.
Gravitational particle creation in a stiff matter dominated universe
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lankinen, Juho; Vilja, Iiro, E-mail: jumila@utu.fi, E-mail: vilja@utu.fi
A scenario for gravitational particle creation in a stiff matter dominated flat Friedmann-Robertson-Walker universe is presented. The primary creation of scalar particles is calculated using quantum field theory in curved spacetime and it is found to be strongly dependent on the scalar mass and the expansion parameter of the universe. The particle creation is most effective for a very massive scalar field and large expansion parameter. We demonstrate the phenomenon by applying it to cosmological toy model scenario, where secondary particles are created by the scalar field decay.
Gravitational particle creation in a stiff matter dominated universe
NASA Astrophysics Data System (ADS)
Lankinen, Juho; Vilja, Iiro
2017-08-01
A scenario for gravitational particle creation in a stiff matter dominated flat Friedmann-Robertson-Walker universe is presented. The primary creation of scalar particles is calculated using quantum field theory in curved spacetime and it is found to be strongly dependent on the scalar mass and the expansion parameter of the universe. The particle creation is most effective for a very massive scalar field and large expansion parameter. We demonstrate the phenomenon by applying it to cosmological toy model scenario, where secondary particles are created by the scalar field decay.
NASA Astrophysics Data System (ADS)
Hanumagowda, B. N.; Gonchigara, Thippeswamy; Santhosh Kumar, J.; MShiva Kumar, H.
2018-04-01
Exponential slider bearings with porous facing is analysed in this article. The modified Reynolds equation is derived for the Exponential porous slider bearing with MHD and couple stress fluid. Computed values of Steady film pressure, Steady load capacity, Dynamic stiffness and Damping coefficient are presented in graphical form. The Steady film pressure, Steady load capacity, Dynamic stiffness and Damping coefficient decreases with increasing values of permeability parameter and increases with increasing values of couplestress parameter and Hartmann number.
NASA Astrophysics Data System (ADS)
Wang, Jing; Shen, Huoming; Zhang, Bo; Liu, Juan
2018-06-01
In this paper, we studied the parametric resonance issue of an axially moving viscoelastic nanobeam with varying velocity. Based on the nonlocal strain gradient theory, we established the transversal vibration equation of the axially moving nanobeam and the corresponding boundary condition. By applying the average method, we obtained a set of self-governing ordinary differential equations when the excitation frequency of the moving parameters is twice the intrinsic frequency or near the sum of certain second-order intrinsic frequencies. On the plane of parametric excitation frequency and excitation amplitude, we can obtain the instability region generated by the resonance, and through numerical simulation, we analyze the influence of the scale effect and system parameters on the instability region. The results indicate that the viscoelastic damping decreases the resonance instability region, and the average velocity and stiffness make the instability region move to the left- and right-hand sides. Meanwhile, the scale effect of the system is obvious. The nonlocal parameter exhibits not only the stiffness softening effect but also the damping weakening effect, while the material characteristic length parameter exhibits the stiffness hardening effect and damping reinforcement effect.
Analytically optimal parameters of dynamic vibration absorber with negative stiffness
NASA Astrophysics Data System (ADS)
Shen, Yongjun; Peng, Haibo; Li, Xianghong; Yang, Shaopu
2017-02-01
In this paper the optimal parameters of a dynamic vibration absorber (DVA) with negative stiffness is analytically studied. The analytical solution is obtained by Laplace transform method when the primary system is subjected to harmonic excitation. The research shows there are still two fixed points independent of the absorber damping in the amplitude-frequency curve of the primary system when the system contains negative stiffness. Then the optimum frequency ratio and optimum damping ratio are respectively obtained based on the fixed-point theory. A new strategy is proposed to obtain the optimum negative stiffness ratio and make the system remain stable at the same time. At last the control performance of the presented DVA is compared with those of three existing typical DVAs, which were presented by Den Hartog, Ren and Sims respectively. The comparison results in harmonic and random excitation show that the presented DVA in this paper could not only reduce the peak value of the amplitude-frequency curve of the primary system significantly, but also broaden the efficient frequency range of vibration mitigation.
Sensitivity analysis on the effective stiffness properties of 3-D orthotropic honeycomb cores
NASA Astrophysics Data System (ADS)
Karakoç, Alp
2018-01-01
The present study investigates the influences of representative volume element RVE mesh and material parameters, here cell wall elastic moduli, on the effective stiffness properties of three dimensional orthotropic honeycomb cores through strain driven computational homogenization in the finite element framework. For this purpose, case studies were carried out, for which hexagonal cellular RVEs were generated, meshed with eight node linear brick finite elements of varying numbers. Periodic boundary conditions were then implemented on the RVE boundaries by using one-to-one nodal match for the corresponding corners, edges and surfaces for the imposed macroscopic strains. As a novelty, orthotropic material properties were assigned for each cell wall by means of the transformation matrices following the cell wall orientations. Thereafter, simulations were conducted and volume averaged macroscopic stresses were obtained. Eventually, effective stiffness properties were obtained, through which RVE sensitivity analysis was carried out. The investigations indicate that there is a strong relation between number of finite elements and most of the effective stiffness parameters. In addition to this, cell wall elastic moduli also play critical role on the effective properties of the investigated materials.
Reliability optimization design of the gear modification coefficient based on the meshing stiffness
NASA Astrophysics Data System (ADS)
Wang, Qianqian; Wang, Hui
2018-04-01
Since the time varying meshing stiffness of gear system is the key factor affecting gear vibration, it is important to design the meshing stiffness to reduce vibration. Based on the effect of gear modification coefficient on the meshing stiffness, considering the random parameters, reliability optimization design of the gear modification is researched. The dimension reduction and point estimation method is used to estimate the moment of the limit state function, and the reliability is obtained by the forth moment method. The cooperation of the dynamic amplitude results before and after optimization indicates that the research is useful for the reduction of vibration and noise and the improvement of the reliability.
NASA Astrophysics Data System (ADS)
Egorov, A. G.; Kamalutdinov, A. M.; Nuriev, A. N.
2018-05-01
The paper is devoted to study of the aerodynamic forces acting on flat cantilever beams performing flexural vibrations in a viscous fluid. Original method for the force evaluation is presented based on analysis of experimental measurements of a logarithmic decrement of vibrations and relative variation in frequency of duralumin test specimens. The theoretical core of the method is based on the classical theory of bending beam oscillations and quasi-two dimensional model of interaction between a beam and a gas. Using the proposed method, extensive series of experiments for a wide range of oscillations parameters were carried out. The processing of the experimental data allowed to establish the global influence of the aerodynamic effects on beam oscillations and the local force characteristics of each cross-section of the beam in the form of universal functions of dimensionless amplitude and dimensionless frequency of oscillation. The obtained estimates of the drag and added mass forces showed a good correspondence with the available numerical and experimental data practically in the entire range of the investigated parameters.
NASA Technical Reports Server (NTRS)
Abbott, Frank T., Jr.; Kelley, H. Neale; Hampton, Kenneth D.
1963-01-01
A flexibly mounted aircraft engine may under certain conditions experience a self-excited whirling instability involving a coupling between the gyroscopic and aerodynamic forces acting on the propeller, and the inertial, elastic, and damping forces contributed by the power plant, nacelle, and wing. This phenomenon has been called autoprecession, or whirl instability. An experimental investigation was made in the Langley transonic dynamics tunnel at Mach numbers below 0.3 to study some of the pertinent parameters influencing the phenomenon. These parameters included propeller rotational speed, stiffness of the power-plant assembly in the pitch and yaw planes and the ratio of pitch stiffness to yaw stiffness, structural damping of the power-plant assembly in the pitch and yaw planes, simulated fuel load in the wings, and the location and number of autoprecessing powerplant assemblies. A large dynamic-aeroelastic model of a four-engine turboprop transport airplane mounted on a vertical rod in a manner which provided several limited body degrees of freedom was used in the investigation. It was found that the boundary for autoprecession decreased markedly with Increasing proreduction of power-plant stiffness and/or damping, and to a lesser degree decreased with reduction of simulated fuel load in the wings. peller rotational speed generally lowered the autoprecession boundary. This effect was more pronounced as the stiffness was increased. An inboard power plant was found to be more susceptible to autoprecession than an outboard one. Combinations in which two or more power plants had the same level of reduced stiffness resulted in autoprecession boundaries considerably lower than that of a single power plant with the same level of reduced stiffness.
Investigation into discretization methods of the six-parameter Iwan model
NASA Astrophysics Data System (ADS)
Li, Yikun; Hao, Zhiming; Feng, Jiaquan; Zhang, Dingguo
2017-02-01
Iwan model is widely applied for the purpose of describing nonlinear mechanisms of jointed structures. In this paper, parameter identification procedures of the six-parameter Iwan model based on joint experiments with different preload techniques are performed. Four kinds of discretization methods deduced from stiffness equation of the six-parameter Iwan model are provided, which can be used to discretize the integral-form Iwan model into a sum of finite Jenkins elements. In finite element simulation, the influences of discretization methods and numbers of Jenkins elements on computing accuracy are discussed. Simulation results indicate that a higher accuracy can be obtained with larger numbers of Jenkins elements. It is also shown that compared with other three kinds of discretization methods, the geometric series discretization based on stiffness provides the highest computing accuracy.
Li, Gang; Wu, Hui-Kun; Wu, Xiao-Wei; Cao, Zhe; Tu, Yuan-Chao; Ma, Yi; Wang, Wei-Qing; Cheng, Jian; Zhou, Zi-Hua
2018-02-12
Small dense low density lipoprotein-cholesterol (sdLDL-C), cholesterol ratios and carotid-femoral pulse wave velocity (cf-PWV) impart risk for all-cause morbidity and mortality independently of conventional cardiovascular disease (CVD) risk factors. This study was designed to identify feasible indicators for predicting arterial stiffness progression. We followed up 816 normotensive participants without diabetes or CVD for nearly 5.0 years. Cholesterol parameters, ratios and other clinical and laboratory data were collected at baseline. cf-PWV were measured at baseline and the end of follow-up. PWV progression subjects had higher levels of PWV parameters, sdLDL-C and TG/HDL-C ratio. sdLDL-C and TG/HDL-C were significantly correlated with all PWV parameters. Multiple regression models showed that sdLDL-C was closely associated with follow-up PWV (β = 0.222, p < 0.001) and △PWV (β = 0.275, p < 0.001). TG/HDL-C was only one cholesterol ratios that associated with all PWV parameters. sdLDL-C (OR = 2.070, 95%CI: 1.162 to 3.688, p = 0.014) and TG/HDL-C (OR = 1.355, 95%CI: 1.136 to 1.617, p = 0.001) could significantly determine the progression of PWV after correction for covariates. High sd-LDL-C quantiles subjects were more likely to develop arterial stiffness progression than low quantiles (Tertiles 3 vs Tertiles1, RR = 2.867, 95%CI: 1.106 to 7.434, p = 0.03). We founded that sdLDL-C and TG/HDL-C ratio can independently predict arterial stiffness progression in normotensive subjects, and high level sdLDL-C and TG/HDL-C ratio were associated with a higher risk of arterial stiffness.
Bending spring rate investigation of nanopipette for cell injection.
Shen, Yajing; Zhang, Zhenhai; Fukuda, Toshio
2015-04-17
Bending of nanopipette tips during cell penetration is a major cause of cell injection failure. However, the flexural rigidity of nanopipettes is little known due to their irregular structure. In this paper, we report a quantitative method to estimate the flexural rigidity of a nanopipette by investigating its bending spring rate. First nanopipettes with a tip size of 300 nm are fabricated from various glass tubes by laser pulling followed by focused ion beam (FIB) milling. Then the bending spring rate of the nanopipettes is investigated inside a scanning electron microscope (SEM). Finally, a yeast cell penetration test is performed on these nanopipettes, which have different bending spring rates. The results show that nanopipettes with a higher bending spring rate have better cell penetration capability, which confirms that the bending spring rate may well reflect the flexural rigidity of a nanopipette. This method provides a quantitative parameter for characterizing the mechanical property of a nanopipette that can be potentially taken as a standard specification in the future. This general method can also be used to estimate other one-dimensional structures for cell injection, which will greatly benefit basic cell biology research and clinical applications.
Bending spring rate investigation of nanopipette for cell injection
NASA Astrophysics Data System (ADS)
Shen, Yajing; Zhang, Zhenhai; Fukuda, Toshio
2015-04-01
Bending of nanopipette tips during cell penetration is a major cause of cell injection failure. However, the flexural rigidity of nanopipettes is little known due to their irregular structure. In this paper, we report a quantitative method to estimate the flexural rigidity of a nanopipette by investigating its bending spring rate. First nanopipettes with a tip size of 300 nm are fabricated from various glass tubes by laser pulling followed by focused ion beam (FIB) milling. Then the bending spring rate of the nanopipettes is investigated inside a scanning electron microscope (SEM). Finally, a yeast cell penetration test is performed on these nanopipettes, which have different bending spring rates. The results show that nanopipettes with a higher bending spring rate have better cell penetration capability, which confirms that the bending spring rate may well reflect the flexural rigidity of a nanopipette. This method provides a quantitative parameter for characterizing the mechanical property of a nanopipette that can be potentially taken as a standard specification in the future. This general method can also be used to estimate other one-dimensional structures for cell injection, which will greatly benefit basic cell biology research and clinical applications.
Design of an adjustable bipod flexure for a large-aperture mirror of a space camera.
Liu, Bei; Wang, Wei; Qu, Yan-Jun; Li, Xu-Peng; Wang, Xiao; Zhao, Hui
2018-05-20
An adjustable bipod flexure (ABF) technique for a large-aperture mirror of a space camera is presented. The proposed flexure mount can decrease the surface distortions caused by the machining error and the assembly error of the mirror assembly (MA) in a horizontal optical testing layout. Through the analysis of the compliance matrix of conventional bipod flexure, the positional relationship between the rotation center and the apex of the flexure is investigated. Then, the principle of the adjustable flexure, known as the trapezoidal switching principle, is proposed based on the analysis result. The structure and application of the flexure are also described. The optical performance of the mirror mounted by the adjustable flexures in different misalignments was performed using finite element methods. The result shows that the astigmatic aberration due to gravity is effectively reduced by adjusting the mount, and the root-mean-square value of the mirror can be minimized with the misalignment between the flexure pivot and the neutral plane minimized. New monolithic bipod flexures, based on the optimal regulating variable Δ u according to the measurement results, are manufactured to replace the ABFs to secure the mirror's safety against launch loads. Modal analysis verified the mechanical safety of the MA with respect to the new monolithic flexures.
Li, Zhi-Yong; Xu, Tian-Ying; Zhang, Sai-Long; Zhou, Xiao-Ming; Xu, Xue-Wen; Guan, Yun-Feng; Lo, Ming; Miao, Chao-Yu
2013-09-01
Ambulatory arterial stiffness index (AASI) has been proposed as a new measure of arterial stiffness for predicting cardio-cerebro-vascular morbidity and mortality. However, there has been no research on the direct relationships between AASI and arterial stiffness-determining factors. We utilized beat-to-beat intra-aortic blood pressure (BP) telemetry to characterize AASI in Wistar-Kyoto (WKY) and spontaneously hypertensive rats (SHR). By determination of aortic structural components and analysis of their correlations with AASI, we provided the first direct evidence for the associations between AASI and arterial stiffness-determining factors including the collagen content and collagen/elastin. Ambulatory arterial stiffness index was positively correlated with pulse pressure in both WKY and SHR, less dependent on BP and BP variability than pulse pressure, and relatively stable, especially the number of BP readings not less than ~36. The correlations between AASI and aortic components were comparable for various AASI values derived from BP readings not less than ~36. Not only AASI but also BP variability and pulse pressure demonstrated a direct relationship with arterial stiffness. These findings indicate AASI may become a routine measure in human arterial stiffness assessment. It is recommended to use a cluster of parameters such as AASI, BP variability, and pulse pressure for evaluating arterial stiffness. © 2013 John Wiley & Sons Ltd.
Zócalo, Yanina; Farro, Ignacio; Farro, Federico; Scasso, Santiago; Bia, Daniel
2015-01-01
Introduction. Flow-mediated dilation (FMD), low flow-mediated constriction (L-FMC), and reactive hyperemia-related changes in carotid-to-radial pulse wave velocity (ΔPWVcr%) could offer complementary information about both “recruitability” and “resting” endothelial function (EF). Carotid-to-femoral pulse wave velocity (PWVcf) and pulse wave analysis-derived parameters (i.e., AIx@75) are the gold standard methods for noninvasive evaluation of aortic stiffness and central hemodynamics. If healthy pregnancy is associated with both changes in resting and recruitable EF, as well as in several arterial parameters, it remains unknown and/or controversial. Objectives. To simultaneously and noninvasively assess in healthy pregnant (HP) and nonpregnant (NP) women central parameters in conjunction with “basal and recruitable” EF, employing new complementary approaches. Methods. HP (n = 11, 34.2 ± 3.3 weeks of gestation) and age- and cardiovascular risk factors-matched NP (n = 22) were included. Aortic blood pressure (BP), AIx@75, PWVcf, common carotid stiffness, and intima-media thickness, as well as FMD, L-FMC, and ΔPWVcr %, were measured. Results. Aortic BP, stiffness, and AIx@75 were reduced in HP. ΔPWVcr% and FMD were enhanced in HP in comparison to NP. No differences were found in L-FMC between groups. Conclusion. HP is associated with reduced aortic stiffness, central BP, wave reflections, and enhanced recruitable, but not resting, EF. PMID:26421317
Rolling Element Bearing Stiffness Matrix Determination (Presentation)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guo, Y.; Parker, R.
2014-01-01
Current theoretical bearing models differ in their stiffness estimates because of different model assumptions. In this study, a finite element/contact mechanics model is developed for rolling element bearings with the focus of obtaining accurate bearing stiffness for a wide range of bearing types and parameters. A combined surface integral and finite element method is used to solve for the contact mechanics between the rolling elements and races. This model captures the time-dependent characteristics of the bearing contact due to the orbital motion of the rolling elements. A numerical method is developed to determine the full bearing stiffness matrix corresponding tomore » two radial, one axial, and two angular coordinates; the rotation about the shaft axis is free by design. This proposed stiffness determination method is validated against experiments in the literature and compared to existing analytical models and widely used advanced computational methods. The fully-populated stiffness matrix demonstrates the coupling between bearing radial, axial, and tilting bearing deflections.« less
NASA Astrophysics Data System (ADS)
Qi, Chenkun; Zhao, Xianchao; Gao, Feng; Ren, Anye; Sun, Qiao
2016-06-01
The hardware-in-the-loop (HIL) contact simulator is to simulate the contact process of two flying objects in space. The contact stiffness and damping are important parameters used for the process monitoring, compliant contact control and force compensation control. In this study, a contact stiffness and damping identification approach is proposed for the HIL contact simulation with the force measurement delay. The actual relative position of two flying objects can be accurately measured. However, the force measurement delay needs to be compensated because it will lead to incorrect stiffness and damping identification. Here, the phase lead compensation is used to reconstruct the actual contact force from the delayed force measurement. From the force and position data, the contact stiffness and damping are identified in real time using the recursive least squares (RLS) method. The simulations and experiments are used to verify that the proposed stiffness and damping identification approach is effective.
Central arterial characteristics of gout patients with chronic kidney diseases.
Celik, Gulperi; Yilmaz, Sema; Kebapcilar, Levent; Gundogdu, Ali
2017-05-01
The aim of this study was to investigate the relationship between central blood pressure, arterial stiffness parameters and renal function parameters in gout patients with chronic kidney disease (CKD) and without CKD. The study enrolled 48 gout patients and 32 control subjects. Central blood pressure, arterial stiffness parameters and renal function parameters in gout patients were investigated. The vascular measurements were performed with an arteriograph. Of the gout patients, 40.1% had CKD. The 24-h pulse pressure (PP) (P < 0.001), central systolic blood pressure (SBP) (P < 0.001), central diastolic blood pressure (DBP) (P < 0.001), cardiac output (CO) (P < 0.001) and peripheral resistance (P = 0.004) were significantly higher in the all patients with gout compared to healthy control subjects. Moreover, when the gout patients with and without CKD were compared, the gout patients with CKD had higher 24-h PP (P = 0.009), 24-h augmentation index standardized to a heart rate of 75 beats per min (AIx@75) (P < 0.023), daytime PP (P = 0.001), daytime AIx@75 (P = 0.027), and nighttime PP (P = 0.035) than the gout patients without CKD. In our study, gout patients with CKD had worse and more emphasized evidence of arterial stiffness than gout patients without CKD. Further investigations with large sample sizes are needed to evaluate the effect of CKD on the arterial stiffness of gout patients. © 2015 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.
Reduced arterial stiffness in very fit boys and girls.
Weberruß, Heidi; Pirzer, Raphael; Schulz, Thorsten; Böhm, Birgit; Dalla Pozza, Robert; Netz, Heinrich; Oberhoffer, Renate
2017-01-01
Low cardiorespiratory fitness is associated with higher cardiovascular risk, whereas high levels of cardiorespiratory fitness protect the cardiovascular system. Carotid intima-media thickness and arterial distensibility are well-established parameters to identify subclinical cardiovascular disease. Therefore, this study investigated the influence of cardiorespiratory fitness and muscular strength on carotid intima-media thickness and arterial distensibility in 697 children and adolescents (376 girls), aged 7-17 years. Cardiorespiratory fitness and strength were measured with the test battery FITNESSGRAM; carotid intima-media thickness, arterial compliance, elastic modulus, stiffness index β, and pulse wave velocity β were assessed by B- and M-mode ultrasound at the common carotid artery. In bivariate correlation, cardiorespiratory fitness was significantly associated with all cardiovascular parameters and was an independent predictor in multivariate regression analysis. No significant associations were obtained for muscular strength. In a one-way variance analysis, very fit boys and girls (58 boys and 74 girls>80th percentile for cardiorespiratory fitness) had significantly decreased stiffness parameters (expressed in standard deviation scores) compared with low fit subjects (71 boys and 77 girls<20th percentile for cardiorespiratory fitness): elastic modulus -0.16±1.02 versus 0.19±1.17, p=0.009; stiffness index β -0.15±1.08 versus 0.16±1.1, p=0.03; and pulse wave velocity β -0.19±1.02 versus 0.19±1.14, p=0.005. Cardiorespiratory fitness was associated with healthier arteries in children and adolescents. Comparison of very fit with unfit subjects revealed better distensibility parameters in very fit boys and girls.
Felfel, R M; Ahmed, I; Parsons, A J; Walker, G S; Rudd, C D
2011-10-01
Several studies have investigated self-reinforced polylactic acid (SR-PLA) and polyglycolic acid (SR-PGA) rods which could be used as intramedullary (IM) fixation devices to align and stabilise bone fractures. This study investigated totally bioresorbable composite rods manufactured via compression moulding at ~100 °C using phosphate glass fibres (of composition 50P(2)O(5)-40CaO-5Na(2)O-5Fe(2)O(3) in mol%) to reinforce PLA with an approximate fibre volume fraction (v(f)) of 30%. Different fibre architectures (random and unidirectional) were investigated and pure PLA rods were used as control samples. The degradation profiles and retention of mechanical properties were investigated and PBS was selected as the degradation medium. Unidirectional (P50 UD) composite rods had 50% higher initial flexural strength as compared to PLA and 60% higher in comparison to the random mat (P50 RM) composite rods. Similar initial profiles for flexural modulus were also seen comparing the P50 UD and P50 RM rods. Higher shear strength properties were seen for P50 UD in comparison to P50 RM and PLA rods. However, shear stiffness values decreased rapidly (after a week) whereas the PLA remained approximately constant. For the compressive strength studies, P50 RM and PLA rods remained approximately constant, whilst for the P50 UD rods a significantly higher initial value was obtained, which decreased rapidly after 3 days immersion in PBS. However, the mechanical properties decreased after immersion in PBS as a result of the plasticisation effect of water within the composite and degradation of the fibres. The fibres within the random and unidirectional composite rods (P50 RM and P50 UD) degraded leaving behind microtubes as seen from the SEM micrographs (after 28 days degradation) which in turn created a porous structure within the rods. This was the main reason attributed for the increase seen in mass loss and water uptake for the composite rods (~17% and ~16%, respectively). Copyright © 2011 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Velazquez, Antonio; Swartz, R. Andrew
2013-04-01
Renewable energy sources like wind are important technologies, useful to alleviate for the current fossil-fuel crisis. Capturing wind energy in a more efficient way has resulted in the emergence of more sophisticated designs of wind turbines, particularly Horizontal-Axis Wind Turbines (HAWTs). To promote efficiency, traditional finite element methods have been widely used to characterize the aerodynamics of these types of multi-body systems and improve their design. Given their aeroelastic behavior, tapered-swept blades offer the potential to optimize energy capture and decrease fatigue loads. Nevertheless, modeling special complex geometries requires huge computational efforts necessitating tradeoffs between faster computation times at lower cost, and reliability and numerical accuracy. Indeed, the computational cost and the numerical effort invested, using traditional FE methods, to reproduce dependable aerodynamics of these complex-shape beams are sometimes prohibitive. A condensed Spinning Finite Element (SFE) method scheme is presented in this study aimed to alleviate this issue by means of modeling wind-turbine rotor blades properly with tapered-swept cross-section variations of arbitrary order via Lagrangian equations. Axial-flexural-torsional coupling is carried out on axial deformation, torsion, in-plane bending and out-of-plane bending using super-convergent elements. In this study, special attention is paid for the case of damped yaw effects, expressed within the described skew-symmetric damped gyroscopic matrix. Dynamics of the model are analyzed by achieving modal analysis with complex-number eigen-frequencies. By means of mass, damped gyroscopic, and stiffness (axial-flexural-torsional coupling) matrix condensation (order reduction), numerical analysis is carried out for several prototypes with different tapered, swept, and curved variation intensities, and for a practical range of spinning velocities at different rotation angles. A convergence study for the resulting natural frequencies is performed to evaluate the dynamic collateral effects of tapered-swept blade profiles in spinning motion using this new model. Stability analysis in boundary conditions of the postulated model is achieved to test the convergence and integrity of the mathematical model. The proposed framework presumes to be particularly suitable to characterize models with complex-shape cross-sections at low computation cost.
High temperature structural sandwich panels
NASA Astrophysics Data System (ADS)
Papakonstantinou, Christos G.
High strength composites are being used for making lightweight structural panels that are being employed in aerospace, naval and automotive structures. Recently, there is renewed interest in use of these panels. The major problem of most commercial available sandwich panels is the fire resistance. A recently developed inorganic matrix is investigated for use in cases where fire and high temperature resistance are necessary. The focus of this dissertation is the development of a fireproof composite structural system. Sandwich panels made with polysialate matrices have an excellent potential for use in applications where exposure to high temperatures or fire is a concern. Commercial available sandwich panels will soften and lose nearly all of their compressive strength temperatures lower than 400°C. This dissertation consists of the state of the art, the experimental investigation and the analytical modeling. The state of the art covers the performance of existing high temperature composites, sandwich panels and reinforced concrete beams strengthened with Fiber Reinforced Polymers (FRP). The experimental part consists of four major components: (i) Development of a fireproof syntactic foam with maximum specific strength, (ii) Development of a lightweight syntactic foam based on polystyrene spheres, (iii) Development of the composite system for the skins. The variables are the skin thickness, modulus of elasticity of skin and high temperature resistance, and (iv) Experimental evaluation of the flexural behavior of sandwich panels. Analytical modeling consists of a model for the flexural behavior of lightweight sandwich panels, and a model for deflection calculations of reinforced concrete beams strengthened with FRP subjected to fatigue loading. The experimental and analytical results show that sandwich panels made with polysialate matrices and ceramic spheres do not lose their load bearing capability during severe fire exposure, where temperatures reach several hundred degrees Centigrade. Hence the material has excellent potential for various types of applications. The analytical predictions from both models provide reasonably accurate results. Glass, AR-glass, carbon and Nicalon tows and carbon fabrics could be successfully used as skin reinforcements increasing the flexural stiffness and strength of the core. No occurrence of fiber delamination was observed.
NASA Astrophysics Data System (ADS)
Masoumi, Nafiseh
There are several disadvantages correlated with current heart valve replacement, including anticoagulation therapy for patients with mechanical valves and the low durability of bioprosthetic valves. The non-viable nature of such devices is a critical drawback especially for pediatric cases due to the inability of the graft to grow in vivo with the patients. A tissue engineered heart valve (TEHV) with remodeling and growth ability, is conceptually appealing to use in the surgical repair and could serve as a permanent replacements when operating for pediatric valvular lesions. It is critical that scaffolds for functional heart valve tissue engineering, be capable of mimicking the native leaflet's structure and mechanical properties at the time of implantation. Meanwhile, the scaffolds should be able to support cellular proliferation and native-like tissue formation as the TEHV remodels toward a scaffold-free state. Our overall hypothesis is that an "ideal" engineered construct, designed based on native leaflet's structure and mechanics, will complement a native heart valve leaflet in providing benchmarks for use in the design of clinically-applicable TEHV. This hypothesis was addressed through several experiments conducted in the present study. To establish a functional biomimetic TEHV, we developed scaffolds capable of matching the anisotropic stiffness of native leaflet while promoting native-like cell and collagen content and supporting the ECM generation. Scaffolds with various polymer contents (e.g., poly (glycerol sebacate) (PGS) and poly (epsilon-caprolactone) (PCL)) and structural designs (e.g., microfabricated and microfibrous scaffolds), were fabricated based on native leaflet's structure and mechanics. It was found that the tri-layered scaffold, designed with assembly of microfabricated PGS and microfibrous PGS/PCL was a functional leaflet capable of promoting tissue formation. Furthermore, to investigate the effect of cyclic stress and flexure individually on the TEHV development, we designed a simple and novel stretch-flexure bioreactor in which samples were subjected to well-defined stimulations with a controlled strain-rate. The stretch and flexure was found to accelerate and increase tissue formation on the microfabricated PGS scaffolds cultivated in the bioreactors.
Ferrari, Gianfranco; Khir, Ashraf W; Fresiello, Libera; Di Molfetta, Arianna; Kozarski, Maciej
2011-09-01
We investigated the effects of the intra-aortic balloon pump (IABP) on endocardial viability ratio (EVR), cardiac output (CO), end-systolic (V(es)) and end-diastolic (V(ed)) ventricular volumes, total coronary blood flow (TCBF), and ventricular energetics (external work [EW], pressure-volume area [PVA]) under different ventricular (E(max) and diastolic stiffness) and circulatory (arterial compliance) parameters. We derived a hybrid model from a computational model, which is based on merging computational and hydraulic submodels. The lumped parameter computational submodel consists of left and right hearts and systemic, pulmonary, and coronary circulations. The hydraulic submodel includes part of the systemic arterial circulation, essentially a silicone rubber tube representing the aorta, which contains a 40-mL IAB. EVR, CO, V(es), and V(ed), TCBF and ventricular energetics (EW, PVA) were analyzed against the ranges of left ventricular E(max) (0.3-0.5-1 mm Hg/cm(3)) and diastolic stiffness V(stiffness) (≈0.08 and ≈0.3 mm Hg/cm(3), obtained by changing diastolic stiffness constant) and systemic arterial compliance (1.8-2.5 cm(3)/mm Hg). All experiments were performed comparing the selected variables before and during IABP assistance. Increasing E(maxl) from 0.5 to 2 mm Hg/cm(3) resulted in IABP assistance producing lower percentage changes in the selected variables. The changes in ventricular diastolic stiffness strongly influence both absolute value of EVR and its variations during IABP (71 and 65% for lower and higher arterial compliance, respectively). V(ed) and V(es) changes are rather small but higher for lower E(max) and higher V(stiffness). Lower E(max) and higher V(stiffness) resulted in higher TCBF and CO during IABP assistance (∼35 and 10%, respectively). The use of this hybrid model allows for testing real devices in realistic, stable, and repeatable circulatory conditions. Specifically, the presented results show that IABP performance is dependent, at least in part, on left ventricular filling, ejection characteristics, and arterial compliance. It is possible in this way to simulate patient-specific conditions and predict the IABP performance at different values of the circulatory or ventricular parameters. Further work is required to study the conditions for heart recovery modeling, baroreceptor controls, and physiological feedbacks. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Arterial stiffness, central hemodynamics, and cardiovascular risk in hypertension
Palatini, Paolo; Casiglia, Edoardo; Gąsowski, Jerzy; Głuszek, Jerzy; Jankowski, Piotr; Narkiewicz, Krzysztof; Saladini, Francesca; Stolarz-Skrzypek, Katarzyna; Tikhonoff, Valérie; Van Bortel, Luc; Wojciechowska, Wiktoria; Kawecka-Jaszcz, Kalina
2011-01-01
This review summarizes several scientific contributions at the recent Satellite Symposium of the European Society of Hypertension, held in Milan, Italy. Arterial stiffening and its hemodynamic consequences can be easily and reliably measured using a range of noninvasive techniques. However, like blood pressure (BP) measurements, arterial stiffness should be measured carefully under standardized patient conditions. Carotid-femoral pulse wave velocity has been proposed as the gold standard for arterial stiffness measurement and is a well recognized predictor of adverse cardiovascular outcome. Systolic BP and pulse pressure in the ascending aorta may be lower than pressures measured in the upper limb, especially in young individuals. A number of studies suggest closer correlation of end-organ damage with central BP than with peripheral BP, and central BP may provide additional prognostic information regarding cardiovascular risk. Moreover, BP-lowering drugs can have differential effects on central aortic pressures and hemodynamics compared with brachial BP. This may explain the greater beneficial effect provided by newer antihypertensive drugs beyond peripheral BP reduction. Although many methodological problems still hinder the wide clinical application of parameters of arterial stiffness, these will likely contribute to cardiovascular assessment and management in future clinical practice. Each of the abovementioned parameters reflects a different characteristic of the atherosclerotic process, involving functional and/or morphological changes in the vessel wall. Therefore, acquiring simultaneous measurements of different parameters of vascular function and structure could theoretically enhance the power to improve risk stratification. Continuous technological effort is necessary to refine our methods of investigation in order to detect early arterial abnormalities. Arterial stiffness and its consequences represent the great challenge of the twenty-first century for affluent countries, and “de-stiffening” will be the goal of the next decades. PMID:22174583
Uncertainty Modeling for Structural Control Analysis and Synthesis
NASA Technical Reports Server (NTRS)
Campbell, Mark E.; Crawley, Edward F.
1996-01-01
The development of an accurate model of uncertainties for the control of structures that undergo a change in operational environment, based solely on modeling and experimentation in the original environment is studied. The application used throughout this work is the development of an on-orbit uncertainty model based on ground modeling and experimentation. A ground based uncertainty model consisting of mean errors and bounds on critical structural parameters is developed. The uncertainty model is created using multiple data sets to observe all relevant uncertainties in the system. The Discrete Extended Kalman Filter is used as an identification/parameter estimation method for each data set, in addition to providing a covariance matrix which aids in the development of the uncertainty model. Once ground based modal uncertainties have been developed, they are localized to specific degrees of freedom in the form of mass and stiffness uncertainties. Two techniques are presented: a matrix method which develops the mass and stiffness uncertainties in a mathematical manner; and a sensitivity method which assumes a form for the mass and stiffness uncertainties in macroelements and scaling factors. This form allows the derivation of mass and stiffness uncertainties in a more physical manner. The mass and stiffness uncertainties of the ground based system are then mapped onto the on-orbit system, and projected to create an analogous on-orbit uncertainty model in the form of mean errors and bounds on critical parameters. The Middeck Active Control Experiment is introduced as experimental verification for the localization and projection methods developed. In addition, closed loop results from on-orbit operations of the experiment verify the use of the uncertainty model for control analysis and synthesis in space.
Fibromyalgia and its clinical relevance in renal transplant recipients.
Erkmen Uyar, M; Sezer, S; Bal, Z; Guliyev, O; Tutal, E; Genctoy, G; Kulah, E; Ozdemir Acar, N; Haberal, M
2015-05-01
Recent evidence suggests that fibromyalgia syndrome (FS) is associated with inflammation and endothelial dysfunction. Our aim was to determine the prevalence of FS in renal transplant recipients and to identify possible links between FS and clinical and laboratory parameters. Ninety-nine kidney transplant recipients with normal graft functions (37.15 ± 10.83 years old, 67 male) were enrolled in the study. All subjects completed the Fibromyalgia Impact Questionnaire (FIQ). The biochemical and clinical parameters in the 1st post-transplantation year were retrospectively recorded. Cardiovascular parameters, including body composition analyses (Tanita), ambulatory blood pressure monitoring data, and pulse-wave velocity, were cross-sectionally analyzed. Mean FIQ score for the whole group was 21.4 ± 14.7. Eight patients had FIQ score >50, and these patients had significantly higher left ventricular mass index than patients with lower FIQ score (P = .048). Patients were divided according to their physical impairment score (PIS): PIS ≥5 (n = 50) and PIS <5 (n = 49). Patients with higher PIS had significantly higher serum creatinine (P = .047) and lower eGFR values (P = .008) than patients with lower PIS. Patients were also evaluated with the use of the stiffness score (SS): patients with (n = 41) and without (n = 58) stiffness. Patients with stiffness had significantly higher office systolic (P = .027) and diastolic (P = .044) blood pressure, body mass index (P = .033), and sagittal abdominal diameter (P = .05) than patients without stiffness. Decline in estimated glomerular filtration rate levels were significantly higher in patients with higher FIQ (7.6% vs 9.4%; P = .0001) than in other patients. FS in renal transplant recipients was strongly associated with hypertension, arterial stiffness, obesity, and renal allograft dysfunction. Copyright © 2015 Elsevier Inc. All rights reserved.
Hogrebe, Nathaniel J; Reinhardt, James W; Tram, Nguyen K; Debski, Anna C; Agarwal, Gunjan; Reilly, Matthew A; Gooch, Keith J
2018-04-01
A cell's insoluble microenvironment has increasingly been shown to exert influence on its function. In particular, matrix stiffness and adhesiveness strongly impact behaviors such as cell spreading and differentiation, but materials that allow for independent control of these parameters within a fibrous, stromal-like microenvironment are very limited. In the current work, we devise a self-assembling peptide (SAP) system that facilitates user-friendly control of matrix stiffness and RGD (Arg-Gly-Asp) concentration within a hydrogel possessing a microarchitecture similar to stromal extracellular matrix. In this system, the RGD-modified SAP sequence KFE-RGD and the scrambled sequence KFE-RDG can be directly swapped for one another to change RGD concentration at a given matrix stiffness and total peptide concentration. Stiffness is controlled by altering total peptide concentration, and the unmodified base peptide KFE-8 can be included to further increase this stiffness range due to its higher modulus. With this tunable system, we demonstrate that human mesenchymal stem cell morphology and differentiation are influenced by both gel stiffness and the presence of functional cell binding sites in 3D culture. Specifically, cells 24 hours after encapsulation were only able to spread out in stiffer matrices containing KFE-RGD. Upon addition of soluble adipogenic factors, soft gels facilitated the greatest adipogenesis as determined by the presence of lipid vacuoles and PPARγ-2 expression, while increasing KFE-RGD concentration at a given stiffness had a negative effect on adipogenesis. This three-component hydrogel system thus allows for systematic investigation of matrix stiffness and RGD concentration on cell behavior within a fibrous, three-dimensional matrix. Physical cues from a cell's surrounding environment-such as the density of cell binding sites and the stiffness of the surrounding material-are increasingly being recognized as key regulators of cell function. Currently, most synthetic biomaterials used to independently tune these parameters lack the fibrous structure characteristic of stromal extracellular matrix, which can be important to cells naturally residing within stromal tissues. In this manuscript, we describe a 3D hydrogel encapsulation system that provides user-friendly control over matrix stiffness and binding site concentration within the context of a stromal-like microarchitecture. Binding site concentration and gel stiffness both influenced cell spreading and differentiation, highlighting the utility of this system to study the independent effects of these material properties on cell function. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Nonlinear vibration analysis of an eccentric rotor with unbalance magnetic pull
NASA Astrophysics Data System (ADS)
Song, Z.; Ma, Z.
2010-08-01
The unbalance magnetic pull of an eccentric water turbine generator set rotor has important influence on its vibration. The magnetic stiffness matrix is introduced to express the energy of the air gap magnetic field. Two vibration models are constructed through the Lagrange Equation. The difference of the two models is the boundary supporting conditions: one is rigid support and the other is elastic support through bearing. The influence of the magnetic stiffness and the elastic support on the critical speed of the rotor is studied using the Liapunov nonlinear vibration theory. The vibration amplitude of the rotor is calculated taking the magnetic stiffness and level eccentricity force into account. The sensitivity of the magnetic, mechanical and bearing parameters to the critical speed is analyzed. Some conclusions may be benefit to the study the dynamic characters of the generator set shaft system which concludes all the magnetic, mechanical and hydraulic parameters.
Arterial Stiffness and Renal Replacement Therapy: A Controversial Topic
Fischer, Edmundo Cabrera; Zócalo, Yanina; Galli, Cintia; Bia, Daniel
2015-01-01
The increase of arterial stiffness has been to have a significant impact on predicting mortality in end-stage renal disease patients. Pulse wave velocity (PWV) is a noninvasive, reliable parameter of regional arterial stiffness that integrates the vascular geometry and arterial wall intrinsic elasticity and is capable of predicting cardiovascular mortality in this patient population. Nevertheless, reports on PWV in dialyzed patients are contradictory and sometimes inconsistent: some reports claim the arterial wall stiffness increases (i.e., PWV increase), others claim that it is reduced, and some even state that it augments in the aorta while it simultaneously decreases in the brachial artery pathway. The purpose of this study was to analyze the literature in which longitudinal or transversal studies were performed in hemodialysis and/or peritoneal dialysis patients, in order to characterize arterial stiffness and the responsiveness to renal replacement therapy. PMID:26064684
Ambient Vibration Testing for Story Stiffness Estimation of a Heritage Timber Building
Min, Kyung-Won; Kim, Junhee; Park, Sung-Ah; Park, Chan-Soo
2013-01-01
This paper investigates dynamic characteristics of a historic wooden structure by ambient vibration testing, presenting a novel estimation methodology of story stiffness for the purpose of vibration-based structural health monitoring. As for the ambient vibration testing, measured structural responses are analyzed by two output-only system identification methods (i.e., frequency domain decomposition and stochastic subspace identification) to estimate modal parameters. The proposed methodology of story stiffness is estimation based on an eigenvalue problem derived from a vibratory rigid body model. Using the identified natural frequencies, the eigenvalue problem is efficiently solved and uniquely yields story stiffness. It is noteworthy that application of the proposed methodology is not necessarily confined to the wooden structure exampled in the paper. PMID:24227999
Hu, Yuantai; Xue, Huan; Hu, Ting; Hu, Hongping
2008-01-01
This paper studies the performance of an energy harvester with a piezoelectric bimorph (PB) and a real electrochemical battery (ECB), both are connected as an integrated system through a rectified dc-dc converter (DDC). A vibrating PB can scavenge energy from the operating environment by the electromechanical coupling. A DDC can effectively match the optimal output voltage of the harvesting structure to the battery voltage. To raise the output power density of PB, a synchronized switch harvesting inductor (SSHI) is used in parallel with the harvesting structure to reverse the voltage through charge transfer between the output electrodes at the transition moments from closed-to open-circuit. Voltage reversal results in earlier arrival of rectifier conduction because the output voltage phases of any two adjacent closed-circuit states are just opposite each other. In principle, a PB is with a smaller, flexural stiffness under closed-circuit condition than under open-circuit condition. Thus, the PB subjected to longer closed-circuit condition will be easier to be accelerated. A larger flexural velocity makes the PB to deflect with larger amplitude, which implies that more mechanical energy will be converted into an electric one. Nonlinear interface between the vibrating PB and the modulating circuit is analyzed in detail, and the effects of SSHI and DDC on the charging efficiency of the storage battery are researched numerically. It was found that the introduction of a DDC in the modulating circuit and an SSHI in the harvesting structure can raise the charging efficiency by several times.
Lai, Lei-Jie; Gu, Guo-Ying; Zhu, Li-Min
2012-04-01
This paper presents a novel decoupled two degrees of freedom (2-DOF) translational parallel micro-positioning stage. The stage consists of a monolithic compliant mechanism driven by two piezoelectric actuators. The end-effector of the stage is connected to the base by four independent kinematic limbs. Two types of compound flexure module are serially connected to provide 2-DOF for each limb. The compound flexure modules and mirror symmetric distribution of the four limbs significantly reduce the input and output cross couplings and the parasitic motions. Based on the stiffness matrix method, static and dynamic models are constructed and optimal design is performed under certain constraints. The finite element analysis results are then given to validate the design model and a prototype of the XY stage is fabricated for performance tests. Open-loop tests show that maximum static and dynamic cross couplings between the two linear motions are below 0.5% and -45 dB, which are low enough to utilize the single-input-single-out control strategies. Finally, according to the identified dynamic model, an inversion-based feedforward controller in conjunction with a proportional-integral-derivative controller is applied to compensate for the nonlinearities and uncertainties. The experimental results show that good positioning and tracking performances are achieved, which verifies the effectiveness of the proposed mechanism and controller design. The resonant frequencies of the loaded stage at 2 kg and 5 kg are 105 Hz and 68 Hz, respectively. Therefore, the performance of the stage is reasonably good in term of a 200 N load capacity. © 2012 American Institute of Physics
Xue, Li; Xu, Wan-Hai; Xu, Jin-Zhi; Zhang, Tong; Bi, Hong-Yuan; Shen, Bao-Zhong
2009-06-20
Researches in arterial elasticity have increased over the past few years. We investigated the effects of simvastatin on vascular stiffness in fat fed rabbits by ultrasonography. Thirty rabbits were assigned randomly to 3 groups: normal control group (A), the cholesterol group (B), simvastatin group (C: high fat diet for 4 weeks and high fat diet + simvastatin for further 4 weeks). Stiffness coefficient, pressure strain elastic modulus and velocity of pulse waves in abdominal aorta and femoral artery were measured by ultrasonographic echo tracking at the end of the 4th and the 8th weeks. At the end of the 4th week, stiffness coefficient, pressure strain elastic modulus and pulse wave velocity of femoral artery were significantly increased in group B compared with those in group A. Similarly, at the end of the 8th week, the same parameters of abdominal aorta were significantly increased in group B compared with those in group A. In contrast, stiffness coefficient, pressure strain elastic modulus and pulse wave velocity of femoral artery were significantly decreased in group C compared with those in group B, however, there was no significant difference in parameters of abdominal aorta between groups B and C. Short term administration of simvastatin can improve the elasticity of femoral artery but not abdominal aorta.
Effect of gloss and heat on the mechanical behaviour of a glass carbomer cement.
Menne-Happ, Ulrike; Ilie, Nicoleta
2013-03-01
The effect of gloss and heat on the mechanical behaviour of a recently launched glass carbomer cement (GCP, GCP dental) was evaluated and compared with resin-modified glass ionomer cements (Fuji II LC, GC and Photac Fil Quick Aplicap, 3M ESPE). 120bar-shaped specimens (n=20) were produced, maintained in distilled water at 37°C and tested after one week. The GCP specimens were cured with and without heat application and with and without gloss. The flexural strength and modulus of elasticity in flexural test as well as the micro-mechanical properties (Vickers Hardness, indentation modulus, creep) of the top and bottom surface were evaluated. The amount and size of the fillers, voids and cracks were compared using a light and a scanning electron microscope. In the flexural test, the resin-modified glass ionomer cements performed significantly better than GCP. Fuji II LC and Photac Fil (Weibull parameter: 17.7 and 14.3) proved superior reliability in the flexural test compared to GCP (1.4-2.6). The highest Vickers Hardness and lowest creep were achieved by GCP, whereas Fuji II LC reached the highest indentation modulus. The results of this study proved that relationships exist between the compositions, microstructures and mechanical properties of the cements. Heat treatment and gloss application did not influence the mechanical properties of GCP. The mechanical properties were basically influenced by the type of cement and its microstructure. Considering the measured mechanical properties, there is no need of using gloss or heat when restoring teeth with GCP. Copyright © 2012 Elsevier Ltd. All rights reserved.
Ice sheet load cycling and fluid underpressures in the Eastern Michigan Basin, Ontario, Canada
Neuzil, Christopher E.; Provost, Alden M.
2014-01-01
Strong fluid underpressures have been detected in Paleozoic strata in the eastern Michigan Basin, with hydraulic heads reaching ~400 m below land surface (~4 MPa underpressure) and ~200 m below sea level in strata where unusually low permeabilities (~10−20–10−23 m2) were measured in situ. Multiple glaciations, including three with as much as 3 km of ice cover at the site in the last 120 ka, suggest a causal link with the underpressures. We examined this possibility using a one-dimensional groundwater flow model incorporating mechanical loading from both ice weight and lithospheric flexure. Because hydrologic and mechanical changes during glaciation are not well characterized and subsurface properties are imperfectly known, the model was used inversely to estimate flexural loads and loosely constrained permeabilities by matching observed pressures. Acceptable matches were obtained for a surprisingly wide range of scenarios with permeabilities close to measured values and plausible flexural loads. Matches were not obtained when too many parameters were preselected, or when permeabilities were constrained to be significantly larger than measured values. In successful model runs groundwater expulsion under glacial-mechanical loads caused the underpressuring, and flexural loads were important if aquifer and sub-glacial pressures were significantly elevated during glaciation. Simulated fluid pressures in the low-permeability strata fluctuated by 30–40 MPa during glacial cycles but resulted in advective transport of only tens of meters or less. Although other mechanisms cannot be ruled out, we conclude that glacial-mechanical forcing of a water-saturated system can explain the observed underpressures.
NASA Astrophysics Data System (ADS)
Zhang, L.; Han, X. X.; Ge, J.; Wang, C. H.
2018-01-01
To determine the relationship between compressive strength and flexural strength of pavement geopolymer grouting material, 20 groups of geopolymer grouting materials were prepared, the compressive strength and flexural strength were determined by mechanical properties test. On the basis of excluding the abnormal values through boxplot, the results show that, the compressive strength test results were normal, but there were two mild outliers in 7days flexural strength test. The compressive strength and flexural strength were linearly fitted by SPSS, six regression models were obtained by linear fitting of compressive strength and flexural strength. The linear relationship between compressive strength and flexural strength can be better expressed by the cubic curve model, and the correlation coefficient was 0.842.
NASA Technical Reports Server (NTRS)
Nemeth, Michael P.
2013-01-01
Nondimensional linear-bifurcation buckling equations for balanced, symmetrically laminated cylinders with negligible shell-wall anisotropies and subjected to uniform axial compression loads are presented. These equations are solved exactly for the practical case of simply supported ends. Nondimensional quantities are used to characterize the buckling behavior that consist of a stiffness-weighted length-to-radius parameter, a stiffness-weighted shell-thinness parameter, a shell-wall nonhomogeneity parameter, two orthotropy parameters, and a nondimensional buckling load. Ranges for the nondimensional parameters are established that encompass a wide range of laminated-wall constructions and numerous generic plots of nondimensional buckling load versus a stiffness-weighted length-to-radius ratio are presented for various combinations of the other parameters. These plots are expected to include many practical cases of interest to designers. Additionally, these plots show how the parameter values affect the distribution and size of the festoons forming each response curve and how they affect the attenuation of each response curve to the corresponding solution for an infinitely long cylinder. To aid in preliminary design studies, approximate formulas for the nondimensional buckling load are derived, and validated against the corresponding exact solution, that give the attenuated buckling response of an infinitely long cylinder in terms of the nondimensional parameters presented herein. A relatively small number of "master curves" are identified that give a nondimensional measure of the buckling load of an infinitely long cylinder as a function of the orthotropy and wall inhomogeneity parameters. These curves reduce greatly the complexity of the design-variable space as compared to representations that use dimensional quantities as design variables. As a result of their inherent simplicity, these master curves are anticipated to be useful in the ongoing development of buckling-design technology.
NASA Astrophysics Data System (ADS)
McQuarrie, Nadine; Rodgers, David W.
1998-04-01
The Eastern Snake River Plain (ESRP) is a linear volcanic basin interpreted by many workers to reflect late Cenozoic migration of North America over the Yellowstone hotspot. Thermal subsidence of this volcanic province with respect to Yellowstone has been documented by several workers, but no one has characterized subsidence with respect to the adjacent Basin and Range Province. This paper documents crustal flexure along the northwest edge of the ESRP, uses flexure to model the dimensions of a dense load beneath the basin, and presents evidence in support of density-driven subsidence and lower crustal flow away from the basin. Crustal flexure adjacent to the ESRP is reflected by the attitudes of Mesozoic fold hinges and Neogene volcanic rocks. Fold hinges formed with a subhorizontal plunge and a trend perpendicular to the ESRP but now show a southward plunge near the ESRP of as much as 20°-25°. We present a contour map of equal fold plunges proximal to the ESRP that shows flexure is roughly parallel to and extends 10-20 km north of the average edge of the ESRP. Flexural profiles indicate the minimum amount of ESRP subsidence, with respect to the Basin and Range; subsidence ranges from 4.5 to 8.5 km. The structural contour map and published seismic and gravity data were used to develop and constrain flexural subsidence models. These models indicate the flexed crust is very weak (flexural parameter of 4-10 km), interpreted to be a result of the high heat flow of the ESRP. Assuming subsidence was induced by emplacement of a dense crustal layer beneath the ESRP, a midcrustal "sill" identified in previous seismic surveys is too wide and probably too thin to produce the measured flexure. New dimensions include a thickness of 17-25 km and a half width of 40-50 km, which place the edge of the sill beneath the edge of the ESRP. The dimensions of the ESRP sill are based on isostatic compensation in the lower crust because compensation in the asthenosphere requires an unreasonable sill thickness of 30+ km and because ESRP seismic, gravity, and heat flow data support lower crustal compensation. Density-driven lower crustal flow away from the ESRP is proposed to accommodate subsidence and maintain isostatic equilibrium. Timing of subsidence is constrained by ESRP exploratory wells, where 6.6 Ma rhyolites at a depth of 1.5 km indicate most subsidence occurred prior to their emplacement, and by strong spatial correlations between plunge contours and Quaternary volcanic rift zones. Two processes interpreted to contribute to the load include an extensive midcrustal mafic load emplaced at ˜10 Ma, which provided the heat source for the initial rhyolitic volcanism on the ESRP, and continuing, localized loads from dikes and sills associated with Quaternary basalts. Widespread ˜10 Ma magmatism and subsidence conflicts with simple time-transgressive migration of the Yellowstone hotspot, indicating a need for revision of the hotspot paradigm.
NASA Astrophysics Data System (ADS)
Yang, Tao; Cao, Qingjie
2018-03-01
This work presents analytical studies of the stiffness nonlinearities SD (smooth and discontinuous) oscillator under displacement and velocity feedback control with a time delay. The SD oscillator can capture the qualitative characteristics of quasi-zero-stiffness and negative-stiffness. We focus mainly on the primary resonance of the quasi-zero-stiffness SD oscillator and the stochastic resonance (SR) of the negative-stiffness SD oscillator. Using the averaging method, we have been analyzed the amplitude response of the quasi-zero-stiffness SD oscillator. In this regard, the optimum time delay for changing the control intensity according to the optimization standard proposed can be obtained. For the optimum time delay, increasing the displacement feedback intensity is advantageous to suppress the vibrations in resonant regime where vibration isolation is needed, however, increasing the velocity feedback intensity is advantageous to strengthen the vibrations. Moreover, the effects of time-delayed feedback on the SR of the negative-stiffness SD oscillator are investigated under harmonic forcing and Gaussian white noise, based on the Langevin and Fokker-Planck approaches. The time-delayed feedback can enhance the SR phenomenon where vibrational energy harvesting is needed. This paper established the relationship between the parameters and vibration properties of a stiffness nonlinearities SD which provides the guidance for optimizing time-delayed control for vibration isolation and vibrational energy harvesting of the nonlinear systems.
Design, analysis, and testing of a flexure-based vibration-assisted polishing device
NASA Astrophysics Data System (ADS)
Gu, Yan; Zhou, Yan; Lin, Jieqiong; Lu, Mingming; Zhang, Chenglong; Chen, Xiuyuan
2018-05-01
A vibration-assisted polishing device (VAPD) composed of leaf-spring and right-circular flexure hinges is proposed with the aim of realizing vibration-assisted machining along elliptical trajectories. To design the structure, energy methods and the finite-element method are used to calculate the performance of the proposed VAPD. An improved bacterial foraging optimization algorithm is used to optimize the structural parameters. In addition, the performance of the VAPD is tested experimentally. The experimental results indicate that the maximum strokes of the two directional mechanisms operating along the Z1 and Z2 directions are 29.5 μm and 29.3 μm, respectively, and the maximum motion resolutions are 10.05 nm and 10.01 nm, respectively. The maximum working bandwidth is 1,879 Hz, and the device has a good step response.
Mok, Chi Chiu; Cha, Hoon Suk; Hidayat, Rudy; Nguyen, Lan Thi Ngoc; Perez, Emmanuel C; Ramachandran, Raveendran; Tsay, Gregory J; Yoo, Dae Hyun
2016-01-01
In patients with rheumatoid arthritis (RA), morning stiffness is linked more to functional disability and pain than disease activity, as assessed by joint counts and markers of inflammation. As part of the Asia Pacific Morning Stiffness in Rheumatoid Arthritis Expert Panel, a group of eight rheumatologists met to formulate consensus points and develop recommendations for the assessment and management of morning stiffness in RA. On the basis of a systematic literature review and expert opinion, a panel of Asian rheumatologists formulated recommendations for the assessment and medical treatment of RA. The panel agreed upon 10 consensus statements on morning stiffness, its assessment and treatment. Specifically, the panel recommended that morning stiffness, pain and impaired morning function should be routinely assessed in clinical practice. Although there are currently no validated tools for these parameters, they should be assessed as part of the patients' reported outcomes in RA. The panel also agreed on the benefits of low-dose glucocorticoids in RA, particularly for the improvement of morning stiffness. These recommendations serve to guide rheumatologists and other stakeholders on the assessment and management of morning stiffness, and help implement the treat-to-target principle in the management of RA. © 2015 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.
Design and parameter estimation of hybrid magnetic bearings for blood pump applications
NASA Astrophysics Data System (ADS)
Lim, Tau Meng; Zhang, Dongsheng; Yang, Juanjuan; Cheng, Shanbao; Low, Sze Hsien; Chua, Leok Poh; Wu, Xiaowei
2009-10-01
This paper discusses the design and parameter estimation of the dynamics characteristics of a high-speed hybrid magnetic bearings (HMBs) system for axial flow blood pump applications. The rotor/impeller of the pump is driven by a three-phase permanent magnet (PM) brushless and sensorless DC motor. It is levitated by two HMBs at both ends in five-degree-of-freedom with proportional-integral-derivative (PID) controllers; among which four radial directions are actively controlled and one axial direction is passively controlled. Test results show that the rotor can be stably supported to speeds of 14,000 rpm. The frequency domain parameter estimation technique with statistical analysis is adopted to validate the stiffness and damping coefficients of the HMBs system. A specially designed test rig facilitated the estimation of the bearing's coefficients in air—in both the radial and axial directions. The radial stiffness of the HMBs is compared to the Ansoft's Maxwell 2D/3D finite element magnetostatic results. Experimental estimation showed that the dynamics characteristics of the HMBs system are dominated by the frequency-dependent stiffness coefficients. The actuator gain was also successfully calibrated and may potentially extend the parameter estimation technique developed in the study of identification and monitoring of the pump's dynamics properties under normal operating conditions with fluid.
Miller, Renee; Kolipaka, Arunark; Nash, Martyn P; Young, Alistair A
2018-03-12
Magnetic resonance elastography (MRE) has been used to estimate isotropic myocardial stiffness. However, anisotropic stiffness estimates may give insight into structural changes that occur in the myocardium as a result of pathologies such as diastolic heart failure. The virtual fields method (VFM) has been proposed for estimating material stiffness from image data. This study applied the optimised VFM to identify transversely isotropic material properties from both simulated harmonic displacements in a left ventricular (LV) model with a fibre field measured from histology as well as isotropic phantom MRE data. Two material model formulations were implemented, estimating either 3 or 5 material properties. The 3-parameter formulation writes the transversely isotropic constitutive relation in a way that dissociates the bulk modulus from other parameters. Accurate identification of transversely isotropic material properties in the LV model was shown to be dependent on the loading condition applied, amount of Gaussian noise in the signal, and frequency of excitation. Parameter sensitivity values showed that shear moduli are less sensitive to noise than the other parameters. This preliminary investigation showed the feasibility and limitations of using the VFM to identify transversely isotropic material properties from MRE images of a phantom as well as simulated harmonic displacements in an LV geometry. Copyright © 2018 John Wiley & Sons, Ltd.
Adenwalla, Sherna F; Graham-Brown, Matthew P M; Leone, Francesca M T; Burton, James O; McCann, Gerry P
2017-08-01
Cardiovascular (CV) disease is the leading cause of death in chronic kidney disease (CKD) and end-stage renal disease (ESRD). A key driver in this pathology is increased aortic stiffness, which is a strong, independent predictor of CV mortality in this population. Aortic stiffening is a potentially modifiable biomarker of CV dysfunction and in risk stratification for patients with CKD and ESRD. Previous work has suggested that therapeutic modification of aortic stiffness may ameliorate CV mortality. Nevertheless, future clinical implementation relies on the ability to accurately and reliably quantify stiffness in renal disease. Pulse wave velocity (PWV) is an indirect measure of stiffness and is the accepted standard for non-invasive assessment of aortic stiffness. It has typically been measured using techniques such as applanation tonometry, which is easy to use but hindered by issues such as the inability to visualize the aorta. Advances in cardiac magnetic resonance imaging now allow direct measurement of stiffness, using aortic distensibility, in addition to PWV. These techniques allow measurement of aortic stiffness locally and are obtainable as part of a comprehensive, multiparametric CV assessment. The evidence cannot yet provide a definitive answer regarding which technique or parameter can be considered superior. This review discusses the advantages and limitations of non-invasive methods that have been used to assess aortic stiffness, the key studies that have assessed aortic stiffness in patients with renal disease and why these tools should be standardized for use in clinical trial work.
Direct structural parameter identification by modal test results
NASA Technical Reports Server (NTRS)
Chen, J.-C.; Kuo, C.-P.; Garba, J. A.
1983-01-01
A direct identification procedure is proposed to obtain the mass and stiffness matrices based on the test measured eigenvalues and eigenvectors. The method is based on the theory of matrix perturbation in which the correct mass and stiffness matrices are expanded in terms of analytical values plus a modification matrix. The simplicity of the procedure enables real time operation during the structural testing.
Muela, Henrique Cotchi Simbo; Costa-Hong, Valeria A; Yassuda, Monica Sanches; Machado, Michel Ferreira; Nogueira, Ricardo de Carvalho; Moraes, Natalia C; Memória, Claudia Maia; Macedo, Thiago A; Bor-Seng-Shu, Edson; Massaro, Ayrton Roberto; Nitrini, Ricardo; Bortolotto, Luiz A
2017-01-01
Aging, hypertension (HTN), and other cardiovascular risk factors contribute to structural and functional changes of the arterial wall. To evaluate whether arterial stiffness (AS) is related to cerebral blood flow changes and its association with cognitive function in patients with hypertension. 211 patients (69 normotensive and 142 hypertensive) were included. Patients with hypertension were divided into 2 stages: HTN stage-1 and HTN stage-2. The mini-mental state examination (MMSE), Montreal Cognitive Assessment (MoCA) and a battery of neuropsychological (NPE) tests were used to determine cognitive function. Pulse wave velocity was measured using the Complior ® . Carotid properties were assessed by radiofrequency ultrasound. Central arterial pressure and augmentation index were obtained using applanation tonometry. Middle cerebral artery flow velocity was measured by transcranial Doppler ultrasonography. Both arterial stiffness parameters and cerebral vasoreactivity worsened in line with HTN severity. There was a negative correlation between breath holding index (BHI) and arterial stiffness parameters. Cognitive performance worsened in line with HTN severity, with statistical difference occurring mainly between the HTN-2 and normotension groups on both the MMSE and MoCA. The same tendency was observed on the NPE tests. Hypertension severity was associated with higher AS, worse BHI, and lower cognitive performance.
Spatial and temporal modulation of joint stiffness during multijoint movement.
Mah, C D
2001-02-01
Joint stiffness measurements during small transient perturbations have suggested that stiffness during movement is different from that observed during posture. These observations are problematic for theories like the classical equilibrium point hypothesis, which suggest that desired trajectories during movement are enforced by joint stiffness. We measured arm impedances during large, slow perturbations to obtain detailed information about the spatial and temporal modulation of stiffness and viscosity during movement. While our measurements of stiffness magnitudes during movement generally agreed with the results of measurements using fast perturbations, they revealed that joint stiffness undergoes stereotyped changes in magnitude and aspect ratio which depend on the direction of movement and show a strong dependence on joint angles. Movement simulations using measured parameters show that the measured modulation of impedance acts as an energy conserving force field to constrain movement. This mechanism allows for a computationally simplified account of the execution of multijoint movement. While our measurements do not rule out a role for afferent feedback in force generation, the observed stereotyped restoring forces can allow a dramatic relaxation of the accuracy requirements for forces generated by other control mechanisms, such as inverse dynamical models.
Nomura, Kenta; Yonezawa, Teru; Mizoguchi, Hiroshi; Takemura, Hiroshi
2016-08-01
This paper presents a method to measure the passive stiffness of an ankle joint in three degrees of freedom (DOF) under two motion speeds (1 Hz and 5 degree/s) using a developed Stewart platform-type device. The developed device can reproduce input motions of the foot in 6 DOF by controlling six pneumatic linear motion actuators. We used the device to measure the passive stiffness of an ankle joint undergoing three kinds of motion, namely dorsi-plantar flexion, inversion-eversion, and adduction-abduction. The measured values of the passive stiffness of the ankle joint in dorsiflexion that we obtained agreed well with that obtained in a previous study, indicating that the developed device is useful for measuring the passive stiffness of ankle joint. In addition, the developed device can be used to measure the stiffness in inversion-eversion and adduction-abduction motions as well, parameters that have never been measured. The results we obtained demonstrated certain interesting features as we varied both the direction and pace of motion (e.g., there were significant differences in the stiffness not only between adduction and abduction during the faster pace, but also between these and the other motions).
Hon, Kam-lun Ellis; Wong, Kin Yee; Leung, Ting-Fan; Chow, Chung-Mo; Ng, Pak-Cheung
2008-01-01
Atopic dermatitis (AD) is characterized by dryness of the skin, pruritus and involvement of the skin flexures. Skin hydration (SH) and integrity, as measured by transepidermal water loss (TEWL), are important parameters for objectively quantifying AD research. To evaluate if sites in the forearm are equivalent to the antecubital fossa for standard SH and TEWL measurements; and to determine the correlations among these measurements and scores of disease severity and quality of life. We evaluated SH and TEWL under standardized conditions at three common measurement sites in the forearm (antecubital flexure, 2 cm below the antecubital flexure, mid-forearm), and determined the SCORing Atopic Dermatitis (SCORAD) score, Nottingham Eczema Severity Score (NESS), and Children's Dermatology Life Quality Index (CDLQI). Significant correlations between clinical scores, SH, and TEWL were obtained at a site 2 cm below the antecubital fossa (r = -0.553, p < 0.001 for SH and SCORAD; r = 0.596, p < 0.001 for TEWL and SCORAD). SH and TEWL were also correlated with long-term severity of AD as measured by NESS (r = -0.494, p = 0.001 for SH; r = 0.430, p = 0.004 for TEWL), while TEWL was significantly correlated with CDLQI (r = 0.323, p = 0.035). Overall, similar significant correlations were obtained at the mid-forearm, but less so at the antecubital fossa. In AD research, three sites on the forearm appear to be convenient for determination of SH and TEWL. This is the first report to demonstrate that significant correlations are obtained among acute and chronic scores of AD disease severity, quality of life, and the bioengineering parameters.
Comparison of Flexural Strength of Different CAD/CAM PMMA-Based Polymers.
Alp, Gülce; Murat, Sema; Yilmaz, Burak
2018-01-28
To compare the flexural strength of different computer-aided design/computer-aided manufacturing (CAD/CAM) poly(methyl methacrylate)-based (PMMA) polymers and conventional interim resin materials after thermocycling. Rectangular-shaped specimens (n = 15, for each material) (25 × 2 × 2 mm 3 ) were fabricated from 3 CAD/CAM PMMA-based polymers (Telio CAD [T]; M-PM-Disc [M]; Polident-PMMA [P]), 1 bis-acrylate composite resin (Protemp 4 [PT]), and 1 conventional PMMA (ArtConcept Artegral Dentine [C]) according to ISO 10477:2004 Standards (Dentistry-Polymer-Based Crown and Bridge Materials). The specimens were subjected to 10,000 thermocycles (5 to 55°C). Three-point flexural strength of the specimens was tested in a universal testing machine at a 1.0 mm/min crosshead speed, and the flexural strength data (σ) were calculated (MPa). The flexural strength values were statistically analyzed using 1-way ANOVA, and Tukey HSD post-hoc test for multiple comparisons (α = 0.05). Flexural strength values ranged between 66.1 ± 13.1 and 131.9 ± 19.8 MPa. There were significant differences among the flexural strengths of tested materials, except for between T and P CAD/CAM PMMA-based polymers (p > 0.05). CAD/CAM PMMA-based polymer M had the highest flexural strength and conventional PMMA had the lowest (p < 0.05). CAD/CAM PMMA-based T and P polymers had significantly higher flexural strength than the bis-acrylate composite resin (p < 0.05), and conventional PMMA (p < 0.0001), and significantly lower flexural strength compared to CAD/CAM PMMA-based M (p < 0.05). The flexural strength of CAD/CAM PMMA-based polymers was greater than the flexural strength of bis-acrylate composite resin, which had a greater flexural strength compared to conventional PMMA resin. © 2018 by the American College of Prosthodontists.
Stress analysis of the space telescope focal plane structure joint
NASA Technical Reports Server (NTRS)
Foster, W. A., Jr.; Shoemaker, W. L.
1985-01-01
Two major efforts were begun concerning the Space Telescope focal plane structure joint. The 3-D solid finite element modeling of the bipod flexure plate was carried out. Conceptual models were developed for the load transfer through the three major bolts to the flexure plate. The flexure plate drawings were reconstructed using DADAM for the purpose of developing a file from which the coordinates of any point on the flexure plate could be determined and also to locate the attachment points of the various components which connect with the flexure plate. For modeling convenience the CADAM drawing of the flexure plate has been divided into several regions which will be subdivided into finite elements using MSGMESH, which is a finite element mesh generator available with MSC/NASTRAN. In addition to the CADAM work on the flexure plate, an effort was also begun to develop computer aided drawings of the peripheral beam which will be used to assist in modeling the connection between it and the flexure plate.
NASA Astrophysics Data System (ADS)
Kontaxis, L. C.; Georgali, A.; Portan, D. V.; Papanicolaou, G. C.
2018-02-01
In the present study, epoxy resin-non-woven cotton fibers fabric composite plates were manufactured by using the vacuum infusion technique. Next, flexural creep-recovery experiments were performed in order to study the viscoelastic behavior of both the neat resin and the composite material manufactured under both dry and wet conditions. A low cost, mechanically operated flexural creep testing machine was designed and manufactured according to ASTM standards, for providing an economical means of performing flexural creep experiments. Initially, specimens were immersed in physiological saline for different periods of time at constant temperature of 37°C and subsequently tested under flexural creep conditions in order to study the effect of saline absorption on the creep-recovery behavior of the composites. The specific environmental conditions were chosen such as to simulate the real conditions existed into the human body. The combined effect of applied stress, time of immersion, creep time and amount of saline absorbed on the overall flexural viscoelastic behavior of composites was studied. The maximum amount of saline absorbed by the composites was 3.2%, which is double the saline intake of pure resin. It is believed that the 1.5% extra saline was absorbed into the now formed interphase between the matrix and the hydrophobic cotton fibers. It was observed that the creep strain increases as the immersion time increases. This is believed to occur because of the cumulative effect of absorbed saline from the fibers, the matrix, as well as from the fiber-matrix interphase resulting in the fiber matrix debonding and easier relaxation of the macromolecules at higher moisture contents leading to larger deformations at longer times. However, it should be noted that the strain levels of the epoxy resin/cotton fibers fabric composites, never surpassed those of the pure resin, indicating that the fabric successfully reinforces the composite even under the immersion of the latter in saline. Finally, experimental results were fitted using Burger's model and a detailed analysis of the model and the variation of the four characteristic parameters describing the model with time of immersion is given. Several interesting results were derived which are useful for the future application of the cotton - epoxy composites in medical applications such as in orthopedics.
Recent Intermediate Depth Earthquakes in El Salvador, Central Mexico, Cascadia and South-West Japan
NASA Astrophysics Data System (ADS)
Lemoine, A.; Gardi, A.; Gutscher, M.; Madariaga, R.
2001-12-01
We studied occurence and source parameters of several recent intermediate depth earthquakes. We concentrated on the Mw=7.7 salvadorian earthquake which took place on January 13, 2001. It was a good example of the high seismic risk associated to such kind of events which occur closer to the coast than the interplate thrust events. The Salvadorian earthquake was an intermediate depth downdip extensional event which occured inside the downgoing Cocos plate, next to the downdip flexure where the dip increases sharply before the slab sinks more steeply. This location corresponds closely to the position of the Mw=5.7 1996 and Mw=7.3 1982 downdip extensional events. Several recent intermediate depth earthquakes occured in subduction zones exhibiting a ``flat slab'' geometry with three distinct flexural bends where flexural stress may be enhanced. The Mw=6.7 Geiyo event showed a downdip extensional mechanism with N-S striking nodal planes. This trend was highly oblique to the trench (Nankai Trough), yet consistent with westward steepening at the SW lateral termination of the SW Japan flat slab. The Mw=6.8 Olympia earthquake in the Cascadia subduction zone occured at the downdip termination of the Juan de Fuca slab, where plate dip increases from about 5o to over 30o. The N-S orientation of the focal planes, parallel to the trench indicated downdip extension. The location at the downdip flexure corresponds closely to the estimated positions of the 1949 M7.1 Olympia and 1965 M6.5 Seattle-Tacoma events. Between 1994 and 1999, in Central Mexico, an unusually high intermediate depth seismicity occured where several authors proposed a flat geometry for the Cocos plate. Seven events of magnitude between Mw=5.9 and Mw=7.1 occured. Three of them were downdip compressional and four where down-dip extensional. We can explain these earthquakes by flexural stresses at down-dip and lateral terminations of the supposed flat segment. Even if intermediate depth earthquakes occurence could be favored by stress transfer between intermediate depth and interplate zone during the earthquake cycle, flexural stresses associated with bendings which are not only present at ``flat slab'' geometry but also at ``normal'' dipping subduction zone, seem to govern the location of intermediate depth seismicity and to explain their focal mechanisms in El Salvador, SW Japon, Cascadia and Central Mexico.
NASA Technical Reports Server (NTRS)
Wilson, Maywood L.; Johnson, Gary S.; Macconochie, Ian O.
1987-01-01
Aramid-reinforced composite materials of equal fiber volume and varied polymer thermoset matrices were pultruded and flexurally tested to failure. The objective was to improve the flexural properties of aramid-reinforced pultrusions. Pultrusions of both sized and unsized aramid fiber with four different resin systems were compared to determine the effects of sizing compounds and postcuring on flexural strength, fiber wettability, and fiber-to-resin interface bonding. Improvements in flexural strength resulting from pretreatments with the sizing solutions used were marginal. The most significant improvements in flexural properties resulted from postcuring. Flexural strengths ranged from a low of 39,647 psi (273MPa) to a high of 80,390 psi (554 MPa), an overall increase of 103 percent. The fact that postcuring improved the flexural properties of the pultrusions of the four resin systems indicates that a full cure did not occur in any of the resin systems during the pultrusion process. The increased flexural strengths of the polyester and vinyl ester pultrusions were the most surprising. The four resin systems examined were Interplastic Corporation VE 8300 vinyl ester, Ashland Chemical Company Aropol 7430 Polyester, and Shell Chemical Company Epon 9302 and Epon 9310 epoxides.
Contact stiffness of regularly patterned multi-asperity interfaces
NASA Astrophysics Data System (ADS)
Li, Shen; Yao, Quanzhou; Li, Qunyang; Feng, Xi-Qiao; Gao, Huajian
2018-02-01
Contact stiffness is a fundamental mechanical index of solid surfaces and relevant to a wide range of applications. Although the correlation between contact stiffness, contact size and load has long been explored for single-asperity contacts, our understanding of the contact stiffness of rough interfaces is less clear. In this work, the contact stiffness of hexagonally patterned multi-asperity interfaces is studied using a discrete asperity model. We confirm that the elastic interaction among asperities is critical in determining the mechanical behavior of rough contact interfaces. More importantly, in contrast to the common wisdom that the interplay of asperities is solely dictated by the inter-asperity spacing, we show that the number of asperities in contact (or equivalently, the apparent size of contact) also plays an indispensable role. Based on the theoretical analysis, we propose a new parameter for gauging the closeness of asperities. Our theoretical model is validated by a set of experiments. To facilitate the application of the discrete asperity model, we present a general equation for contact stiffness estimation of regularly rough interfaces, which is further proved to be applicable for interfaces with single-scale random roughness.
Stem cell migration and mechanotransduction on linear stiffness gradient hydrogels
Hadden, William J.; Young, Jennifer L.; Holle, Andrew W.; McFetridge, Meg L.; Kim, Du Yong; Wijesinghe, Philip; Taylor-Weiner, Hermes; Wen, Jessica H.; Lee, Andrew R.; Bieback, Karen; Vo, Ba-Ngu; Sampson, David D.; Kennedy, Brendan F.; Spatz, Joachim P.; Choi, Yu Suk
2017-01-01
The spatial presentation of mechanical information is a key parameter for cell behavior. We have developed a method of polymerization control in which the differential diffusion distance of unreacted cross-linker and monomer into a prepolymerized hydrogel sink results in a tunable stiffness gradient at the cell–matrix interface. This simple, low-cost, robust method was used to produce polyacrylamide hydrogels with stiffness gradients of 0.5, 1.7, 2.9, 4.5, 6.8, and 8.2 kPa/mm, spanning the in vivo physiological and pathological mechanical landscape. Importantly, three of these gradients were found to be nondurotactic for human adipose-derived stem cells (hASCs), allowing the presentation of a continuous range of stiffnesses in a single well without the confounding effect of differential cell migration. Using these nondurotactic gradient gels, stiffness-dependent hASC morphology, migration, and differentiation were studied. Finally, the mechanosensitive proteins YAP, Lamin A/C, Lamin B, MRTF-A, and MRTF-B were analyzed on these gradients, providing higher-resolution data on stiffness-dependent expression and localization. PMID:28507138
Exchange Stiffness in Thin-Film Cobalt Alloys
NASA Astrophysics Data System (ADS)
Eyrich, Charles
The exchange stiffness, Aex, is one of the key parameters controlling magnetization reversal in magnetic materials but is very difficult to measure, especially in thin films. We developed a new technique for measuring the exchange stiffness of a magnetic material based on the formation of a spin spiral within two antiferromagnetically coupled ferromagnetic films [1]. Using this method, I was able to measure the exchange stiffness of thin film Co alloyed with Cr, Fe, Ni, Pd, Pt and Ru. The results of this work showed that the rate at which a substituent element reduces the exchange stiffness is not directly related to its effect on the magnetization of the alloy. These measured trends have been understood by combining measurements of element specific magnetic moments obtained using X-ray magnetic circular dichroism (XMCD) and material specific modeling based on density functional theory (DFT) within the local density approximation (LDA). The experimental results also hint at significant reduction of the exchange stiffness at the interface that can account for the difference between our results and those obtained on bulk materials.
Aging Wire Insulation Assessment by Phase Spectrum Examination of Ultrasonic Guided Waves
NASA Technical Reports Server (NTRS)
Anastasi, Robert F.; Madaras, Eric I.
2003-01-01
Wire integrity has become an area of concern to the aerospace community including DoD, NASA, FAA, and Industry. Over time and changing environmental conditions, wire insulation can become brittle and crack. The cracks expose the wire conductor and can be a source of equipment failure, short circuits, smoke, and fire. The technique of using the ultrasonic phase spectrum to extract material properties of the insulation is being examined. Ultrasonic guided waves will propagate in both the wire conductor and insulation. Assuming the condition of the conductor remains constant then the stiffness of the insulator can be determined by measuring the ultrasonic guided wave velocity. In the phase spectrum method the guided wave velocity is obtained by transforming the time base waveform to the frequency domain and taking the phase difference between two waveforms. The result can then be correlated with a database, derived by numerical model calculations, to extract material properties of the wire insulator. Initial laboratory tests were performed on a simple model consisting of a solid cylinder and then a solid cylinder with a polymer coating. For each sample the flexural mode waveform was identified. That waveform was then transformed to the frequency domain and a phase spectrum was calculated from a pair of waveforms. Experimental results on the simple model compared well to numerical calculations. Further tests were conducted on aircraft or mil-spec wire samples, to see if changes in wire insulation stiffness can be extracted using the phase spectrum technique.
Shu, Deming; Kearney, Steven P.; Preissner, Curt A.
2015-02-17
A method and deformation compensated flexural pivots structured for precision linear nanopositioning stages are provided. A deformation-compensated flexural linear guiding mechanism includes a basic parallel mechanism including a U-shaped member and a pair of parallel bars linked to respective pairs of I-link bars and each of the I-bars coupled by a respective pair of flexural pivots. The basic parallel mechanism includes substantially evenly distributed flexural pivots minimizing center shift dynamic errors.
Zhang, Xiaowei; Tang, Zhifeng; Lv, Fuzai; Pan, Xiaohong
2017-02-01
A wavefront analysis indicates that a flexural wave propagates at a helix angle with respect to the pipe axis. The expression for calculation of the helix angle for each flexural mode is given, and the helix angle dispersion curves for flexural modes are calculated. According to the new understanding of flexural guided waves, a helical comb magnetostrictive patch transducer (HCMPT) is proposed for selectively exciting a single predominant flexural torsional guided wave in a pipe and inspecting spiral welded pipes using flexural waves. A HCMPT contains a pre-magnetized magnetostrictive patch that is helically coupled with the outer surface of a pipe, and a novel compound comb coil that is wrapped around the helical magnetostrictive patch. The proposed wideband HCMPT possesses the direction control ability. A verification experiment indicates that flexural torsional mode T(3,1) at center frequency f=64kHz is effectively actuated by a HCMPT with 13-degree helix angle. Flexural torsional modes T(N,1) with circumferential order N equals 1-5 are selected to inspect a seamless steel pipe, artificial defects are effectively detected by the proposed HCMPT. A 20-degree HCMPT is adopted to inspect a spiral welded pipe, an artificial notch with cross section loss CSL=2.7% is effectively detected by using flexural waves. Copyright © 2016 Elsevier B.V. All rights reserved.
Estimating flexural rigidity and load magnitude required for formation of Ross Island flexure moat
NASA Astrophysics Data System (ADS)
Jha, S.; Harry, D. L.; Wenman, C. P.
2017-12-01
Lithospheric flexural subsidence around Ross Island in West Antarctica led to formation of the Ross Island flexure moat. This subsidence was caused by two major volcanic phases on Ross Island. The first phase saw the first surficial expression of Ross Island and volcanism at Mt. Bird to the north of Ross Island, which lasted from 5.2 - 2.9 Ma. The second phase lasted from 1.78 Ma to present and is comprised of eruptions from Mt. Terror to the east, Mt. Erebus to the west and Hut Point Peninsula (HPP) to the south of Ross Island. Flexural subsidence of the lithosphere due to volcanism on Ross Island led to formation of a sedimentary moat around the island, which is preserved in stratigraphy imaged on seismic reflection profiles. We identified 5 unconformities (from deepest upward Ri, RMU1, RMU2, RMU3, RMU4) in the seismic surveys which correspond to flexural subsidence episodes around Ross Island since early Pliocene. Ri (4.4 Ma) lies near the bottom of the flexural moat and RMU4 near the seafloor and top of the moat fill. These unconformities were used to make isopach maps to constrain flexure modeling of the area. Isopach maps show circular or semi-circular flexure basins around Ross Island which is approximated using a continuous plate, point load flexure model. We used Ri - sea floor isopach to constrain flexure models for 5 profiles centered on 4 volcanic centers and trending radially out of Ross Island. Flexure models along two profiles beginning on Mt. Bird and one profile off HPP show a flexural rigidity range of 1.47 - 6.44 x 1018 Nm with load center of mass on Mt. Bird and on HPP, respectively. A similar model along a profile initiating on Mt. Terror, passing through Mt Erebus and extending west of Ross Island across the moat, yielded a higher flexural rigidity estimate of 2.03 x 1019 Nm with load centered at Mt. Erebus. A flexure model to the north east of Ross Island along a profile beginning at Mt Terror and trending north, provide the highest flexural rigidity estimate of 6.9 x 1019 Nm. The load magnitudes determined from these flexure models lie in the range of 4.6 x 1015 N - 4.3 x 1016 N. This is less than the topographic load (6.9 x 1017 N estimated from BEDMAP2) produced by the island by one to two orders of magnitude. The difference in load magnitudes suggest anomalously low densities caused by high lower crust and mantle temperatures in the region.
Avian Feathers: An Examination of Lightweight Resilience and Bioinspired Designs
NASA Astrophysics Data System (ADS)
Sullivan, Tarah Naoe
In bird flight, the majority of the wing surface consists of highly refined and hierarchically organized beta-keratinous feathers. Thus, flight feathers contain ingenious combinations of components that optimize lift, stiffness, aerodynamics, and damage resistance. Their design involves two main parts: a central shaft which prescribes stiffness and lateral vanes that allow for the capture of air. Within the feather vane, barbs branch from the shaft and barbules branch from barbs, forming a flat surface and ensuring lift. Microhooks at the end of barbules hold barbs tightly together, providing a close-knit, unified structure and enabling repair of the vane through the reattachment of un-hooked junctions. In this dissertation, unique aspects of feather architecture are explored to uncover principles translatable to the design of modern aerospace materials and structures. Specifically, understudied aspects of the feather's lightweight yet resilient properties are investigated. This research has revealed several novel characteristics of the feather. Allometric scaling relationships are developed linking the geometry of a bird's wing components to its flight characteristics and total mass. Barbule spacing within the feather vane is found to be 8-16 microm for birds ranging from 0.02-11 kg. Additionally, it is discovered that strength is recovered with the shape recovery property of feathers, and a mechanism for this phenomenon is proposed. Barbule adhesion within the vane is found to prevent barbs from twisting in flexure, maintaining the vane's stiffness, and the extent to which unzipping these connections affects the feather's ability to capture air is related to barb shape. Directional permeability of the feather vane is experimentally confirmed and related to the intricate microstructure of barbules. Lastly, the exceptional architecture of the feather motivated the design of novel bioinspired structures with tailored and unique properties. The avian feather serves as an excellent springboard for designs that can be adapted to enhance synthetic materials and structures.
Östling, Gerd; Nilsson, Peter M.
2015-01-01
Introduction Arterial stiffness is an independent risk factor for cardiovascular morbidity and can be assessed by applanation tonometry by measuring pulse wave velocity (PWV) and augmentation index (AIX) by pressure pulse wave analysis (PWA). As an inexpensive and operator independent alternative, photoelectric plethysmography (PPG) has been introduced with analysis of the digital volume pulse wave (DPA) and its second derivatives of wave reflections. Objective The objective was to investigate the repeatability of arterial stiffness parameters measured by digital pulse wave analysis (DPA) and the associations to applanation tonometry parameters. Methods and Results 112 pregnant and non-pregnant individuals of different ages and genders were examined with SphygmoCor arterial wall tonometry and Meridian DPA finger photoplethysmography. Coefficients of repeatability, Bland-Altman plots, intraclass correlation coefficients and correlations to heart rate (HR) and body height were calculated for DPA variables, and the DPA variables were compared to tonometry variables left ventricular ejection time (LVET), PWV and AIX. No DPA variable showed any systematic measurement error or excellent repeatability, but dicrotic index (DI), dicrotic dilatation index (DDI), cardiac ejection elasticity index (EEI), aging index (AI) and second derivatives of the crude pulse wave curve, b/a and e/a, showed good repeatability. Overall, the correlations to AIX were better than to PWV, with correlations coefficients >0.70 for EEI, AI and b/a. Considering the level of repeatability and the correlations to tonometry, the overall best DPA parameters were EEI, AI and b/a. The two pansystolic time parameters, ejection time compensated (ETc) by DPA and LVET by tonometry, showed a significant but weak correlation. Conclusion For estimation of the LV function, ETc, EEI and b/a are suitable, for large artery stiffness EEI, and for small arteries DI and DDI. The only global parameter, AI, showed a high repeatability and the overall best correlations with AIX and PWV. PMID:26291079
Performance of buried pipe installation : technical summary.
DOT National Transportation Integrated Search
2010-05-01
The goal of this research project was to determine the effects of geometric and mechanical parameters characterizing the soil-structure interaction developed in a buried pipe installation. Parameters such as pipe ring stiff ness, bedding thickness, t...
NASA Astrophysics Data System (ADS)
Shinno, Yuko; Ishimoto, Takuya; Saito, Mitsuru; Uemura, Reo; Arino, Masumi; Marumo, Keishi; Nakano, Takayoshi; Hayashi, Mikako
2016-01-01
In clinical dentistry, since fracture is a major cause of tooth loss, better understanding of mechanical properties of teeth structures is important. Dentin, the major hard tissue of teeth, has similar composition to bone. In this study, we investigated the mechanical properties of human dentin not only in terms of mineral density but also using structural and quality parameters as recently accepted in evaluating bone strength. Aged crown and root dentin (age ≥ 40) exhibited significantly lower flexural strength and toughness than young dentin (age < 40). Aged dentin, in which the dentinal tubules were occluded with calcified material, recorded the highest mineral density; but showed significantly lower flexural strength than young dentin. Dentin with strong alignment of the c-axis in hydroxyapatite exhibited high fracture strength, possibly because the aligned apatite along the collagen fibrils may reinforce the intertubular dentin. Aged dentin, showing a high advanced glycation end-products (AGEs) level in its collagen, recorded low flexural strength. We first comprehensively identified significant factors, which affected the inferior mechanical properties of aged dentin. The low mechanical strength of aged dentin is caused by the high mineral density resulting from occlusion of dentinal tubules and accumulation of AGEs in dentin collagen.
Chapter 8:Properties of red maple laminated veneer lumber
Robert J. Ross; Xiping Wang; Brian K. Brashaw; John W. Forsman; John R. Erickson
2005-01-01
The purpose of the work reported in this chapter was to examine the flexural properties of LVL manufactured from ultrasonically rated red maple veneer sheets. The specific objectives were: 1. to determine the flatwise and edgewise bending properties of ½ inch-(1.3-cm-) thick red maple LVL billets, and 2. to examine the relationship between nondestructive parameters of...
NASA Astrophysics Data System (ADS)
Ma, Yanhui; He, Minghua; Shen, Wenhou; Ren, Gexue
2015-12-01
In this paper, a simple and designable shock isolation system with ideal high-static-low-dynamic-stiffness (HSLDS) is proposed, which is intended for the horizontal plane shock isolation application. In this system, the isolated object is suspended by several bearing cables and constrained by a number of uniformly distributed pretensioned cables in the horizontal plane, where the low dynamic stiffness of the system is main controlled by the pretension of the planar cables, whilst the high static stiffness is determined by the axial stiffness of the planar cables and their geometric settings. To obtain the HSLDS characteristic of the system, a brief theoretical description of the relationship between the restoring force and displacement is derived. By obtaining the three-order Taylor expansion with sufficient accuracy of the restoring force, influence of planar cable parameters on the low dynamic and high static stiffness is thus given, therefore, the required HSLDS isolator can be easily designed by adjusting the planar cable length, pretension and tensile stiffness. Finally, the isotropy characteristic of the restoring force of the system with different numbers of planar cables is investigated. To evaluate the performance of the system, a rigid isolated object and flexible cables coupling simulation model considering the contacts of the system is established by using multibody dynamics approach. In this model, flexible cables are simulated by 3-node cable element based on the absolute nodal coordinate formulation; the contact between cable and isolated object is simulated based on Hertz contact theory. Finally, the time-domain shock excitation is converted from the design shock spectrum on the basis of BV043/85 criterion. The design procedure of this isolator and some useful guidelines for choosing cable parameters are presented. In addition, a summary about the performance of the isolators with different numbers of cables shocking in an arbitrary direction is given in the conclusion.
Influence of inhaled nicotine source on arterial stiffness.
Szołtysek-Bołdys, Izabela; Sobczak, Andrzej; Zielińska-Danch, Wioleta; Bartoń, Aleksandra; Koszowski, Bartosz; Kośmider, Leon
2014-01-01
Tobacco smoking leads to changes in hemodynamic parameters such as heart rate and systolic or diastolic blood pressure. It has a direct influence on the elasticity of blood vessels and increases arterial stiffness, which can result in development of atherosclerosis. Data show that the nicotine in tobacco smoke probably is responsible for these changes. Electronic cigarettes (e-cigarettes) were supposedly a healthier alternative to combustible cigarettes because they imitate a process of cigarettes smoking but generate nicotine aerosol without the toxic substances from tobacco combustion. However, the use of e-cigarettes is still controversial because their toxicity, safety and long term use health impact have not been sufficiently studied. The aim of this study was to evaluate changes in arterial stiffness parameters after smoking a cigarette or e-cigarette use. Fifteen healthy women, aged 19-25 years old, smoking ≥5 cigarettes per day for at least two years participated in the study. A non-invasive measurement of arterial stiffness parameters - Stiffness Index (SI) and Reflection Index (RI) - was conducted and systolic and diastolic blood pressure and heart rate were measured before and after smoking a conventional cigarette as well as use of an e-cigarette. Statistically significant changes in the SI and RI were observed before and after smoking of a conventional cigarette [SI: 6.75m/s (6.66 - 6.85, 95% CI) vs 6.56m/s (6.46 - 6.65. 95% CI), p=0.0056; RI: 54.0% (51.5 - 56.7, 95% CI) vs 49.6% (47.5 - 51.8, 95% CI), p=0.010]. The use of e-cigarettes resulted in no statistically significant changes in the SI and RI. After both product use systolic and diastolic blood pressure and heart rate increased but the changes were not statistically significant. In contrast to conventional cigarette use, the use of electronic cigarettes causes no changes in arterial stiffness. This may indicate lower bioavailability of nicotine from the e-cigarette or an additional effect of other substances present in cigarette smoke but absent in an e-cigarette aerosol.
NASA Technical Reports Server (NTRS)
Haftka, Raphael T.; Cohen, Gerald A.; Mroz, Zenon
1990-01-01
A uniform variational approach to sensitivity analysis of vibration frequencies and bifurcation loads of nonlinear structures is developed. Two methods of calculating the sensitivities of bifurcation buckling loads and vibration frequencies of nonlinear structures, with respect to stiffness and initial strain parameters, are presented. A direct method requires calculation of derivatives of the prebuckling state with respect to these parameters. An adjoint method bypasses the need for these derivatives by using instead the strain field associated with the second-order postbuckling state. An operator notation is used and the derivation is based on the principle of virtual work. The derivative computations are easily implemented in structural analysis programs. This is demonstrated by examples using a general purpose, finite element program and a shell-of-revolution program.
The behavior of bonded doubler splices for composite sandwich panels
NASA Technical Reports Server (NTRS)
Zeller, T. A.; Weisahaar, T. A.
1980-01-01
The results of an investigation into the behavior of adhesively bonded doubler splices of two composite material sandwich panels are presented. The splices are studied from three approaches: analytical; numerical (finite elements); and experimental. Several parameters that characterize the splice are developed to determine their influence upon joint strength. These parameters are: doubler overlap length; core stiffness; laminate bending stiffness; the size of the gap between the spliced sandwich panels; and room and elevated temperatures. Similarities and contrasts between these splices and the physically similar single and double lap joints are discussed. The results of this investigation suggest several possible approaches to improving the strength of the sandwich splices.
Design of algorithms for a dispersive hyperbolic problem
NASA Technical Reports Server (NTRS)
Roe, Philip L.; Arora, Mohit
1991-01-01
In order to develop numerical schemes for stiff problems, a model of relaxing heat flow is studied. To isolate those errors unavoidably associated with discretization, a method of characteristics is developed, containing three free parameters depending on the stiffness ratio. It is shown that such 'decoupled' schemes do not take into account the interaction between the wave families, and hence result in incorrect wavespeeds. Schemes can differ by up to two orders of magnitude in their rms errors, even while maintaining second-order accuracy. 'Coupled' schemes which account for the interactions are developed to obtain two additional free parameters. Numerical results are given for several decoupled and coupled schemes.
Effect of train carbody's parameters on vertical bending stiffness performance
NASA Astrophysics Data System (ADS)
Yang, Guangwu; Wang, Changke; Xiang, Futeng; Xiao, Shoune
2016-10-01
Finite element analysis(FEA) and modal test are main methods to give the first-order vertical bending vibration frequency of train carbody at present, but they are inefficiency and waste plenty of time. Based on Timoshenko beam theory, the bending deformation, moment of inertia and shear deformation are considered. Carbody is divided into some parts with the same length, and it's stiffness is calculated with series principle, it's cross section area, moment of inertia and shear shape coefficient is equivalent by segment length, and the fimal corrected first-order vertical bending vibration frequency analytical formula is deduced. There are 6 simple carbodies and 1 real carbody as examples to test the formula, all analysis frequencies are very close to their FEA frequencies, and especially for the real carbody, the error between analysis and experiment frequency is 0.75%. Based on the analytic formula, sensitivity analysis of the real carbody's design parameters is done, and some main parameters are found. The series principle of carbody stiffness is introduced into Timoshenko beam theory to deduce a formula, which can estimate the first-order vertical bending vibration frequency of carbody quickly without traditional FEA method and provide a reference to design engineers.
Kim, Bo-Hyun; Larson, Mark K.; Lawson, Heather E.
2018-01-01
Bumps and other types of dynamic failure have been a persistent, worldwide problem in the underground coal mining industry, spanning decades. For example, in just five states in the U.S. from 1983 to 2014, there were 388 reportable bumps. Despite significant advances in mine design tools and mining practices, these events continue to occur. Many conditions have been associated with bump potential, such as the presence of stiff units in the local geology. The effect of a stiff sandstone unit on the potential for coal bumps depends on the location of the stiff unit in the stratigraphic column, the relative stiffness and strength of other structural members, and stress concentrations caused by mining. This study describes the results of a robust design to consider the impact of different lithologic risk factors impacting dynamic failure risk. Because the inherent variability of stratigraphic characteristics in sedimentary formations, such as thickness, engineering material properties, and location, is significant and the number of influential parameters in determining a parametric study is large, it is impractical to consider every simulation case by varying each parameter individually. Therefore, to save time and honor the statistical distributions of the parameters, it is necessary to develop a robust design to collect sufficient sample data and develop a statistical analysis method to draw accurate conclusions from the collected data. In this study, orthogonal arrays, which were developed using the robust design, are used to define the combination of the (a) thickness of a stiff sandstone inserted on the top and bottom of a coal seam in a massive shale mine roof and floor, (b) location of the stiff sandstone inserted on the top and bottom of the coal seam, and (c) material properties of the stiff sandstone and contacts as interfaces using the 3-dimensional numerical model, FLAC3D. After completion of the numerical experiments, statistical and multivariate analysis are performed using the calculated results from the orthogonal arrays to analyze the effect of these variables. As a consequence, the impact of each of the parameters on the potential for bumps is quantitatively classified in terms of a normalized intensity of plastic dissipated energy. By multiple regression, the intensity of plastic dissipated energy and migration of the risk from the roof to the floor via the pillars is predicted based on the value of the variables. The results demonstrate and suggest a possible capability to predict the bump potential in a given rock mass adjacent to the underground excavations and pillars. Assessing the risk of bumps is important to preventing fatalities and injuries resulting from bumps. PMID:29416902
NASA Astrophysics Data System (ADS)
Kallolimath, Sharan Chandrashekar
For the past several years, many researchers are constantly developing and improving board level drop test procedures and specifications to quantify the solder joint reliability performance of consumer electronics products. Predictive finite element analysis (FEA) by utilizing simulation software has become widely acceptable verification method which can reduce time and cost of the real-time test process. However, due to testing and metrological limitations it is difficult not only to simulate exact drop condition and capture critical measurement data but also tedious to calibrate the system to improve test methods. Moreover, some of the important ever changing factors such as board flexural rigidity, damping, drop height, and drop orientation results in non-uniform stress/strain distribution throughout the test board. In addition, one of the most challenging tasks is to quantify uniform stress and strain distribution throughout the test board and identify critical failure factors. The major contributions of this work are in the four aspects of the drop test in electronics as following. First of all, an analytical FEA model was developed to study the board natural frequencies and responses of the system with the consideration of dynamic stiffness, damping behavior of the material and effect of impact loading condition. An approach to find the key parameters that affect stress and strain distributions under predominate mode responses was proposed and verified with theoretical solutions. Input-G method was adopted to study board response behavior and cut boundary interpolation methods was used to analyze local model solder joint stresses with the development of global/local FEA model in ANSYS software. Second, no ring phenomenon during the drop test was identified theoretically when the test board was modeled as both discrete system and continuous system. Numerical analysis was then conducted by FEA method for detailed geometry of attached chips with solder-joints. No ring test conditions was proposed and verified for the current widely used JEDEC standard. The significance of impact loading parameters such as pulse magnitude, pulse duration, pulse shapes and board dynamic parameter such as linear hysteretic damping and dynamic stiffness were discussed. Third, Kirchhoff's plate theory by principle of minimum potential energy was adopted to develop the FEA formulation to consider the effect of material hysteretic damping for the currently used JEDEC board test and proposed no-ring response test condition. Fourth, a hexagonal symmetrical board model was proposed to address the uniform stress and strain distribution throughout the test board and identify the critical failure factors. Dynamic stress and strain of the hexagonal board model were then compared with standard JEDEC board for both standard and proposed no-ring test conditions. In general, this line of research demonstrates that advanced techniques of FEA analysis can provide useful insights concerning the optimal design of drop test in microelectronics.
Mattila, Kalle; Buttgereit, Frank; Tuominen, Risto
2014-12-01
Work disability remains a considerable problem for many patients with rheumatoid arthritis (RA). Morning stiffness is a symptom of RA associated with early retirement from work and with impaired functional ability. We aimed to explore the patient's perception of the impact of morning stiffness on the working life of patients with RA. A survey was conducted in 11 European countries. Patients of working age, with RA for ≥6 months and morning stiffness ≥3 mornings a week, were interviewed by telephone using a structured questionnaire. Responses were assessed in the total sample and in subgroups defined by severity and duration of morning stiffness and by country. A total of 1,061 respondents completed the survey, 534 were working, 224 were retired and the rest were, i.e. homemakers and unemployed. Among the 534 working respondents, RA-related morning stiffness affected work performance (47 %), resulted in late arrival at work (33 %) and required sick leave in the past month (15 %). Of the 224 retired respondents, 159 (71 %) stopped working earlier than their expected retirement age, with 64 % giving RA-related morning stiffness as a reason. There was a differential impact of increasing severity and increasing duration of morning stiffness on the various parameters studied. There were notable inter-country differences in the impact of RA-related morning stiffness on ability to work and on retirement. This large survey showed that from the patient's perspective, morning stiffness reduces the ability to work in patients with RA and contributes to early retirement.
Adenwalla, Sherna F.; Leone, Francesca M.T.; Burton, James O.; McCann, Gerry P.
2017-01-01
Abstract Cardiovascular (CV) disease is the leading cause of death in chronic kidney disease (CKD) and end-stage renal disease (ESRD). A key driver in this pathology is increased aortic stiffness, which is a strong, independent predictor of CV mortality in this population. Aortic stiffening is a potentially modifiable biomarker of CV dysfunction and in risk stratification for patients with CKD and ESRD. Previous work has suggested that therapeutic modification of aortic stiffness may ameliorate CV mortality. Nevertheless, future clinical implementation relies on the ability to accurately and reliably quantify stiffness in renal disease. Pulse wave velocity (PWV) is an indirect measure of stiffness and is the accepted standard for non-invasive assessment of aortic stiffness. It has typically been measured using techniques such as applanation tonometry, which is easy to use but hindered by issues such as the inability to visualize the aorta. Advances in cardiac magnetic resonance imaging now allow direct measurement of stiffness, using aortic distensibility, in addition to PWV. These techniques allow measurement of aortic stiffness locally and are obtainable as part of a comprehensive, multiparametric CV assessment. The evidence cannot yet provide a definitive answer regarding which technique or parameter can be considered superior. This review discusses the advantages and limitations of non-invasive methods that have been used to assess aortic stiffness, the key studies that have assessed aortic stiffness in patients with renal disease and why these tools should be standardized for use in clinical trial work. PMID:28852490
NASA Astrophysics Data System (ADS)
Korayem, M. H.; Taheri, M.; Ghahnaviyeh, S. D.
2015-08-01
Due to the more delicate nature of biological micro/nanoparticles, it is necessary to compute the critical force of manipulation. The modeling and simulation of reactions and nanomanipulator dynamics in a precise manipulation process require an exact modeling of cantilevers stiffness, especially the stiffness of dagger cantilevers because the previous model is not useful for this investigation. The stiffness values for V-shaped cantilevers can be obtained through several methods. One of them is the PBA method. In another approach, the cantilever is divided into two sections: a triangular head section and two slanted rectangular beams. Then, deformations along different directions are computed and used to obtain the stiffness values in different directions. The stiffness formulations of dagger cantilever are needed for this sensitivity analyses so the formulations have been driven first and then sensitivity analyses has been started. In examining the stiffness of the dagger-shaped cantilever, the micro-beam has been divided into two triangular and rectangular sections and by computing the displacements along different directions and using the existing relations, the stiffness values for dagger cantilever have been obtained. In this paper, after investigating the stiffness of common types of cantilevers, Sobol sensitivity analyses of the effects of various geometric parameters on the stiffness of these types of cantilevers have been carried out. Also, the effects of different cantilevers on the dynamic behavior of nanoparticles have been studied and the dagger-shaped cantilever has been deemed more suitable for the manipulation of biological particles.
Flexural properties untreated and treated kenaf fiber reinforced polypropylene composites
NASA Astrophysics Data System (ADS)
Husin, Muhammad Muslimin; Mustapa, Mohammad Sukri; Wahab, Md Saidin; Arifin, Ahmad Mubarak Tajul; Masirin, Mohd Idrus Mohd; Jais, Farhana Hazwanee
2017-05-01
Today natural fiber polymer composites are being extensively used as alternatives in producing furniture to fulfill society demand instead of saving cost and environmentally friendly. The objective of this search is to investigate the untreated fine and rough kenaf fiber (KF) as well as treated KF reinforced with polypropylene (PP) on the flexural strength. Flexural strengths of pure PP, 10%, and 20% of untreated fine and rough KF by weight to PP have been recorded. In addition, flexural strengths of treated KF soaked with 5% and 10% of Sodium Hydroxide (NaOH) have also been recorded. KF reinforced PP (PP/KF) untreated and treated composites were melt blended and then injection molded to observe their flexural strengths by measuring their threshold. Three point bending test was apply to determine the flexural stress of the composites. The result show treated fine KF produce better flexural performance at 20% PP/KF. Scanning Electron Microscopy (SEM) is used to observe the morphological surface PP/KF. Overall 5% NaOH with 20% PP/KF (Fine KF) show good interfacial bonding PP/KF and best result with flexural stress value 30.25MPa.
Comparative study of flexural strength test methods on CAD/CAM Y-TZP dental ceramics
Xu, Yongxiang; Han, Jianmin; Lin, Hong; An, Linan
2015-01-01
Clinically, fractures are the main cause of computer-aided design and computer-aided manufacturing (CAD/CAM) 3 mol%-yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) all-ceramic dental restorations failure because of repetitive occlusal loading. The goal of this work is to study the effect of test methods and specimen’s size on the flexural strength of five ceramic products. Both bi-axial flexure test (BI) and uni-axial flexure tests (UNI), including three-point flexure test (3PF) and four-point flexure test (4PF), are used in this study. For all five products, the flexural strength is as follows: BI > 3PF > 4PF. Furthermore, specimens with smaller size (3PF-s) have higher values than the bigger ones (3PF). The difference between BI and UNI resulted from the edge flaws in ceramic specimens. The relationship between different UNI (including 3PF-s, 3PF and 4PF) can be explained according to Weibull statistical fracture theory. BI is recommended to evaluate the flexural strength of CAD/CAM Y-TZP dental ceramics. PMID:26816646
Maruo, Yukinori; Nishigawa, Goro; Irie, Masao; Yoshihara, Kumiko; Minagi, Shogo
2015-01-01
High flexural properties are needed for fixed partial denture or implant prosthesis to resist susceptibility to failures caused by occlusal overload. The aim of this investigation was to clarify the effects of four different kinds of fibers on the flexural properties of fiber-reinforced composites. Polyethylene fiber, glass fiber and two types of carbon fibers were used for reinforcement. Seven groups of specimens, 2 × 2 × 25 mm, were prepared (n = 10 per group). Four groups of resin composite specimens were reinforced with polyethylene, glass or one type of carbon fiber. The remaining three groups served as controls, with each group comprising one brand of resin composite without any fiber. After 24-h water storage in 37°C distilled water, the flexural properties of each specimen were examined with static three-point flexural test at a crosshead speed of 0.5 mm/min. Compared to the control without any fiber, glass and carbon fibers significantly increased the flexural strength (p < 0.05). On the contrary, the polyethylene fiber decreased the flexural strength (p < 0.05). Among the fibers, carbon fiber exhibited higher flexural strength than glass fiber (p < 0.05). Similar trends were observed for flexural modulus and fracture energy. However, there was no significant difference in fracture energy between carbon and glass fibers (p > 0.05). Fibers could, therefore, improve the flexural properties of resin composite and carbon fibers in longitudinal form yielded the better effects for reinforcement.
NASA Technical Reports Server (NTRS)
Lowery, Anthony R.; Smith, Robert B.
1994-01-01
Stochastic inversion for flexural loads and flexural rigidity of the continental elastic layer can be accomplished most effectively by using the coherence of gravity and topography. However, the spatial resolution of coherence analysis has been limited by use of two-dimensional periodogram spectra from very large (greater than 10(exp 5)sq km) windows that generally include multiple tectonic features. Using a two-dimensional spectral estimator based on the maximum entropy method, the spatial resolution of flexural proerties can be enhanced by a factor of 4 or more, enabling more detailed analysis at the scale of individual tectonic features. This new approach is used to map the spatial variation of flexural rigidity along the Basin and Range transition to the Colorado Plateau and Middle Rocky Mountains physiographic provinces. Large variations in flexural isostatic responses are found, with rigidities ranging from as low as 8.7 x 10(exp 20) N m (elastic thickness (T(sub e) = 4.6 km) in the Basin and Range to as high as 4.1 x 10(exp 24) N m T(sub e) = 77 km) in the Middle Rocky Mountains. These results compare favorably woith independent determinations of flexural rigidity in the region. Areas of low flexural rigidity correlate strongly with areas of high surface heat flow, as is expected from the contingence of flexural rigidity on a temperature-dependent flow law. Also, late Cenozoic normal faults with large displacements are found primarily in area of low flexural rigidity region. The highest flexural rigidity is found within the Archean Wyoming craton, where evidence suggests that deeply rooted cratonic lithosphere may play a role in determining the distribution of tectonism at the surface.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roberts, G.D.; Ho, B.Ping Hsiao; Wallace, J.F.
1993-02-01
The effects of thermal and mechanical fatigue on the flexural strength of G40-600/PMR-15 cross-ply laminates with ply orientation of (0(2),90(2))2S and (90(2),0(2))2S are examined. The relative importance of shear and tensile stresses is examined by varying the span-to-depth ratios of flexural test specimens from 8 to 45. Acoustic emission signals are measured during the flexural tests in order to monitor the initiation and growth of damage. Optical microscopy is used to examine specimens for resin cracking, delamination, and fiber breaks after testing. Transverse matrix cracks and delaminations occur in all specimens, regardless of ply orientation, span-to-depth ratio, or previous exposuremore » of specimens to thermal and mechanical fatigue. A small amount of fiber tensile fracture occurs in the outer 0 deg ply of specimens with high span-to-depth ratios. Because of the complex failure modes, the flexural test results represent the apparent strengths rather than the true flexural or shear strengths for these cross-ply laminates. Thermal cycling of specimens prior to flexural testing does not reduce the apparent flexural strength or change the mode of failure. However, fewer acoustic events are recorded at all strains during flexural testing of specimens exposed to prior thermal cycling. High temperature thermal cycling (32 to 260 C, 100 cycles) causes a greater reduction in acoustic events than low temperature thermal cycling (-85 to +85 C, 500 cycles). Mechanical cycling (0 to 50 percent of the flexural strength, 100 cycles) has a similar effect, except that acoustic events are reduced only at strains less than the maximum strain applied during flexural fatigue.« less
NASA Technical Reports Server (NTRS)
Roberts, Gary D.; Ho, Barry Ping Hsiao; Wallace, John F.
1993-01-01
The effects of thermal and mechanical fatigue on the flexural strength of G40-600/PMR-15 cross-ply laminates with ply orientation of (0(2),90(2))2S and (90(2),0(2))2S are examined. The relative importance of shear and tensile stresses is examined by varying the span-to-depth ratios of flexural test specimens from 8 to 45. Acoustic emission signals are measured during the flexural tests in order to monitor the initiation and growth of damage. Optical microscopy is used to examine specimens for resin cracking, delamination, and fiber breaks after testing. Transverse matrix cracks and delaminations occur in all specimens, regardless of ply orientation, span-to-depth ratio, or previous exposure of specimens to thermal and mechanical fatigue. A small amount of fiber tensile fracture occurs in the outer 0 deg ply of specimens with high span-to-depth ratios. Because of the complex failure modes, the flexural test results represent the 'apparent' strengths rather than the true flexural or shear strengths for these cross-ply laminates. Thermal cycling of specimens prior to flexural testing does not reduce the apparent flexural strength or change the mode of failure. However, fewer acoustic events are recorded at all strains during flexural testing of specimens exposed to prior thermal cycling. High temperature thermal cycling (32 to 260 C, 100 cycles) causes a greater reduction in acoustic events than low temperature thermal cycling (-85 to +85 C, 500 cycles). Mechanical cycling (0 to 50 percent of the flexural strength, 100 cycles) has a similar effect, except that acoustic events are reduced only at strains less than the maximum strain applied during flexural fatigue.
Shin, Jae-Won; Mooney, David J
2016-10-25
Extracellular matrix stiffness influences biological functions of some tumors. However, it remains unclear how cancer subtypes with different oncogenic mutations respond to matrix stiffness. In addition, the relevance of matrix stiffness to in vivo tumor growth kinetics and drug efficacy remains elusive. Here, we designed 3D hydrogels with physical parameters relevant to hematopoietic tissues and adapted them to a quantitative high-throughput screening format to facilitate mechanistic investigations into the role of matrix stiffness on myeloid leukemias. Matrix stiffness regulates proliferation of some acute myeloid leukemia types, including MLL-AF9 + MOLM-14 cells, in a biphasic manner by autocrine regulation, whereas it decreases that of chronic myeloid leukemia BCR-ABL + K-562 cells. Although Arg-Gly-Asp (RGD) integrin ligand and matrix softening confer resistance to a number of drugs, cells become sensitive to drugs against protein kinase B (PKB or AKT) and rapidly accelerated fibrosarcoma (RAF) proteins regardless of matrix stiffness when MLL-AF9 and BCR-ABL are overexpressed in K-562 and MOLM-14 cells, respectively. By adapting the same hydrogels to a xenograft model of extramedullary leukemias, we confirm the pathological relevance of matrix stiffness in growth kinetics and drug sensitivity against standard chemotherapy in vivo. The results thus demonstrate the importance of incorporating 3D mechanical cues into screening for anticancer drugs.
Ding, Xiaohan; Ye, Ping; Wang, Xiaona; Cao, Ruihua; Yang, Xu; Xiao, Wenkai; Zhang, Yun; Bai, Yongyi; Wu, Hongmei
2017-03-01
This prospective cohort study aimed at identifying association between uric acid (UA) and peripheral arterial stiffness. A prospective cohort longitudinal study was performed according to an average of 4.8 years' follow-up. The demographic data, anthropometric parameters, peripheral arterial stiffness (carotid-radial pulse-wave velocity, cr-PWV) and biomarker variables including UA were examined at both baseline and follow-up. Pearson's correlations were used to identify the associations between UA and peripheral arterial stiffness. Further logistic regressions were employed to determine the associations between UA and arterial stiffness. At the end of follow-up, 1447 subjects were included in the analyses. At baseline, cr-PWV ( r = 0.200, p < 0.001) was closely associated with UA. Furthermore, the follow-up cr-PWV ( r = 0.145, p < 0.001) was also strongly correlated to baseline UA in Pearson's correlation analysis. Multiple regressions also indicated the association between follow-up cr-PWV ( β = 0.493, p = 0.013) and baseline UA level. Logistic regressions revealed that higher baseline UA level was an independent predictor of arterial stiffness severity assessed by cr-PWV at follow-up cross-section. Peripheral arterial stiffness is closely associated with higher baseline UA level. Furthermore, a higher baseline UA level is an independent risk factor and predictor for peripheral arterial stiffness.
Extracting Cell Stiffness from Real-Time Deformability Cytometry: Theory and Experiment.
Mietke, Alexander; Otto, Oliver; Girardo, Salvatore; Rosendahl, Philipp; Taubenberger, Anna; Golfier, Stefan; Ulbricht, Elke; Aland, Sebastian; Guck, Jochen; Fischer-Friedrich, Elisabeth
2015-11-17
Cell stiffness is a sensitive indicator of physiological and pathological changes in cells, with many potential applications in biology and medicine. A new method, real-time deformability cytometry, probes cell stiffness at high throughput by exposing cells to a shear flow in a microfluidic channel, allowing for mechanical phenotyping based on single-cell deformability. However, observed deformations of cells in the channel not only are determined by cell stiffness, but also depend on cell size relative to channel size. Here, we disentangle mutual contributions of cell size and cell stiffness to cell deformation by a theoretical analysis in terms of hydrodynamics and linear elasticity theory. Performing real-time deformability cytometry experiments on both model spheres of known elasticity and biological cells, we demonstrate that our analytical model not only predicts deformed shapes inside the channel but also allows for quantification of cell mechanical parameters. Thereby, fast and quantitative mechanical sampling of large cell populations becomes feasible. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Extracting Cell Stiffness from Real-Time Deformability Cytometry: Theory and Experiment
Mietke, Alexander; Otto, Oliver; Girardo, Salvatore; Rosendahl, Philipp; Taubenberger, Anna; Golfier, Stefan; Ulbricht, Elke; Aland, Sebastian; Guck, Jochen; Fischer-Friedrich, Elisabeth
2015-01-01
Cell stiffness is a sensitive indicator of physiological and pathological changes in cells, with many potential applications in biology and medicine. A new method, real-time deformability cytometry, probes cell stiffness at high throughput by exposing cells to a shear flow in a microfluidic channel, allowing for mechanical phenotyping based on single-cell deformability. However, observed deformations of cells in the channel not only are determined by cell stiffness, but also depend on cell size relative to channel size. Here, we disentangle mutual contributions of cell size and cell stiffness to cell deformation by a theoretical analysis in terms of hydrodynamics and linear elasticity theory. Performing real-time deformability cytometry experiments on both model spheres of known elasticity and biological cells, we demonstrate that our analytical model not only predicts deformed shapes inside the channel but also allows for quantification of cell mechanical parameters. Thereby, fast and quantitative mechanical sampling of large cell populations becomes feasible. PMID:26588562
Stiff, light, strong and ductile: nano-structured High Modulus Steel.
Springer, H; Baron, C; Szczepaniak, A; Uhlenwinkel, V; Raabe, D
2017-06-05
Structural material development for lightweight applications aims at improving the key parameters strength, stiffness and ductility at low density, but these properties are typically mutually exclusive. Here we present how we overcome this trade-off with a new class of nano-structured steel - TiB 2 composites synthesised in-situ via bulk metallurgical spray-forming. Owing to the nano-sized dispersion of the TiB 2 particles of extreme stiffness and low density - obtained by the in-situ formation with rapid solidification kinetics - the new material has the mechanical performance of advanced high strength steels, and a 25% higher stiffness/density ratio than any of the currently used high strength steels, aluminium, magnesium and titanium alloys. This renders this High Modulus Steel the first density-reduced, high stiffness, high strength and yet ductile material which can be produced on an industrial scale. Also ideally suited for 3D printing technology, this material addresses all key requirements for high performance and cost effective lightweight design.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glagolev, Mikhail K.; Vasilevskaya, Valentina V., E-mail: vvvas@polly.phys.msu.ru; Khokhlov, Alexei R.
Impact of mixture composition on self-organization in concentrated solutions of stiff helical and flexible macromolecules was studied by means of molecular dynamics simulation. The macromolecules were composed of identical amphiphilic monomer units but a fraction f of macromolecules had stiff helical backbones and the remaining chains were flexible. In poor solvents the compacted flexible macromolecules coexist with bundles or filament clusters from few intertwined stiff helical macromolecules. The increase of relative content f of helical macromolecules leads to increase of the length of helical clusters, to alignment of clusters with each other, and then to liquid-crystalline-like ordering along a singlemore » direction. The formation of filament clusters causes segregation of helical and flexible macromolecules and the alignment of the filaments induces effective liquid-like ordering of flexible macromolecules. A visual analysis and calculation of order parameter relaying the anisotropy of diffraction allow concluding that transition from disordered to liquid-crystalline state proceeds sharply at relatively low content of stiff components.« less
Fortier, Catherine; Desjardins, Marie-Pier; Agharazii, Mohsen
2018-03-01
Aortic stiffness, measured by carotid-femoral pulse wave velocity (cf-PWV), is used for the prediction of cardiovascular risk. This mini-review describes the nonlinear relationship between cf-PWV and operational blood pressure, presents the proposed methods to adjust for this relationship, and discusses a potential place for aortic-brachial PWV ratio (a measure of arterial stiffness gradient) as a blood pressure-independent measure of vascular aging. PWV is inherently dependent on the operational blood pressure. In cross-sectional studies, PWV adjustment for mean arterial pressure (MAP) is preferred, but still remains a nonoptimal approach, as the relationship between PWV and blood pressure is nonlinear and varies considerably among individuals due to heterogeneity in genetic background, vascular tone, and vascular remodeling. Extrapolations from the blood pressure-independent stiffness parameter β (β 0 ) have led to the creation of stiffness index β, which can be used for local stiffness. A similar approach has been used for cardio-ankle PWV to generate a blood pressure-independent cardio-ankle vascular index (CAVI). It was recently demonstrated that stiffness index β and CAVI remain slightly blood pressure-dependent, and a more appropriate formula has been proposed to make the proper adjustments. On the other hand, the negative impact of aortic stiffness on clinical outcomes is thought to be mediated through attenuation or reversal of the arterial stiffness gradient, which can also be influenced by a reduction in peripheral medium-sized muscular arteries in conditions that predispose to accelerate vascular aging. Arterial stiffness gradient, assessed by aortic-brachial PWV ratio, is emerging to be at least as good as cf-PWV for risk prediction, but has the advantage of not being affected by operating MAP. The negative impacts of aortic stiffness on clinical outcomes are proposed to be mediated through attenuation or reversal of arterial stiffness gradient. Aortic-brachial PWV ratio, a measure of arterial stiffness gradient, is independent of MAP.
The study of stiffness modulus values for AC-WC pavement
NASA Astrophysics Data System (ADS)
Lubis, AS; Muis, Z. A.; Iskandar, T. D.
2018-02-01
One of the parameters of the asphalt mixture in order for the strength and durability to be achieved as required is the stress-and-strain showing the stiffness of a material. Stiffness modulus is a very necessary factor that will affect the performance of asphalt pavements. If the stiffness modulus value decreases there will be a cause of aging asphalt pavement crack easily when receiving a heavy load. The high stiffness modulus asphalt concrete causes more stiff and resistant to bending. The stiffness modulus value of an asphalt mixture material can be obtained from the theoretical (indirect methods) and laboratory test results (direct methods). For the indirect methods used Brown & Brunton method, and Shell Bitumen method; while for the direct methods used the UMATTA tool. This study aims to determine stiffness modulus values for AC-WC pavement. The tests were conducted in laboratory that used 3 methods, i.e. Brown & Brunton Method, Shell Bitumen Method and Marshall Test as a substitute tool for the UMATTA tool. Hotmix asphalt made from type AC-WC with pen 60/70 using a mixture of optimum bitumen content was 5.84% with a standard temperature variation was 60°C and several variations of temperature that were 30, 40, 50, 70 and 80°C. The stiffness modulus value results obtained from Brown & Brunton Method, Shell Bitumen Method and Marshall Test which were 1374,93 Mpa, 235,45 Mpa dan 254,96 Mpa. The stiffness modulus value decreases with increasing temperature of the concrete asphalt. The stiffness modulus value from the Bitumen Shell method and the Marshall Test has a relatively similar value.The stiffness modulus value from the Brown & Brunton method is greater than the Bitumen Shell method and the Marshall Test, but can not measure the stiffness modulus value at temperature above 80°C.
NASA Astrophysics Data System (ADS)
Shokrieh, M. M.; Mahmoudi, A.; Shadkam, H. R.
2015-05-01
The Taguchi method was used to determine the optimum content of a four-parameters cellulose fiber pulp, polyvinyl alcohol (PVA) fibers, a silica fume, and bentonite for cement-based composite sheets. Then cement composite sheets from the hybrid of PVA and the cellulose fiber pulp were manufactured, and their moduli of rapture were determined experimentally. The result obtained showed that cement composites with a hybrid of PVA and cellulose fiber pulp had a higher flexural strength than cellulose-fiber- reinforced cement ones, but this strength was rather similar to that of asbestos-fiber-reinforced cement composites. Also, using the results of flexural tests and an analytical method, the tensile and compressive moduli of the hybrid of PVA and cement sheet were calculated. The hybrid of PVA and cellulose fiber pulp is proposed as an appropriate alternative for substituting asbestos in the Hatschek process.
Chen, Yao; Stark, Nicole M.; Tshabalala, Mandla A.; Gao, Jianmin; Fan, Yongming
2016-01-01
This study investigated weathering performance of an HDPE wood plastic composite reinforced with extracted or delignified wood flour (WF). The wood flour was pre-extracted with three different solvents, toluene/ethanol (TE), acetone/water (AW), and hot water (HW), or sodium chlorite/acetic acid. The spectral properties of the composites before and after artificial weathering under accelerated conditions were characterized by Fourier transform infrared (FTIR) spectroscopy, the surface color parameters were analyzed using colorimetry, and the mechanical properties were determined by a flexural test. Weathering of WPC resulted in a surface lightening and a decrease in wood index (wood/HDPE) and flexural strength. WPCs that were reinforced with delignified wood flour showed higher ΔL* and ΔE* values, together with lower MOE and MOR retention ratios upon weathering when compared to those with non-extracted control and extracted WF. PMID:28773732
NASA Astrophysics Data System (ADS)
Barreto, Roberto; Florencia Carusela, M.; Monastra, Alejandro G.
2017-10-01
We investigate the role that nonlinearity in the interatomic potential has on the thermal conductance of a suspended nanoribbon when it is subjected to a longitudinal strain. To focus on the first cubic and quartic nonlinear terms of a general potential, we propose an atomic system based on an α-β Fermi-Pasta-Ulam nearest neighbor interaction. We perform classical molecular dynamics simulations to investigate the contribution of longitudinal, transversal and flexural modes to the thermal conductance as a function of the α-β parameters and the applied strain. We compare the cases where atoms are allowed to vibrate only in plane (2D) with the case of vibrations in and out of plane (3D). We find that the dependence of conductance on α and β relies on a crossover phenomenon between linear/nonlinear delocalized/localized flexural and transversal modes, driven by an on/off switch of the strain.
NASA Astrophysics Data System (ADS)
Molchanov, E. S.; Yudin, V. E.; Kydralieva, K. A.; Elokhovskii, V. Yu.
2012-07-01
Prepregs of fiber-reinforced plastics based on a PORCHER-43200 carbon twill-weave fabric and two types of binders — thermoreactive and thermoplastic — were fabricated using electrostatic spraying, followed by rolling the prepregs in temperature-controlled calenders. A solid epoxy olygomer with dicyandiamine as a hardener and Fortron® polyphenylene sulfide were used as the thermoreactive and thermoplastic binders. The thermomechanical properties of carbon-fiber-reinforced plastics processed from these prepregs, as well as commercial Sigranex® PREPREGCE8201-200-45 S prepregs as model ones, and composites manufactured from them were investigated for comparison. The latter ones are being used for the design of orthopaedic products. It is shown that the composites based on polyphenylene sulfide are characterized by higher values of flexural strength, flexural and shear moduli, and interlaminar fracture toughness ( G IC), the latter being the most important parameter.
Hillebrand, Matthias; Nouri, Ghazaleh; Hametner, Bernhard; Parragh, Stephanie; Köster, Jelena; Mortensen, Kai; Schwarz, Achim; von Kodolitsch, Yskert; Wassertheurer, Siegfried
2016-05-06
The aim of this work is the investigation of measures of ambulatory brachial and aortic blood pressure and indices of arterial stiffness and aortic wave reflection in Marfan patients. A case-control study was conducted including patients with diagnosed Marfan syndrome following Ghent2 nosology and healthy controls matched for sex, age and daytime brachial systolic blood pressure. For each subject a 24 h ambulatory blood pressure and 24 h pulse wave analysis measurement was performed. All parameters showed a circadian pattern whereby pressure dipping was more pronounced in Marfan patients. During daytime only Marfan patients with aortic root surgery showed increased pulse wave velocity. In contrast, various nighttime measurements, wave reflection determinants and circadian patterns showed a significant difference. The findings of our study provide evidence that ambulatory measurement of arterial stiffness parameters is feasible and that these determinants are significantly different in Marfan syndrome patients compared to controls in particular at nighttime. Further investigation is therefore indicated.
A study of numerical methods for hyperbolic conservation laws with stiff source terms
NASA Technical Reports Server (NTRS)
Leveque, R. J.; Yee, H. C.
1988-01-01
The proper modeling of nonequilibrium gas dynamics is required in certain regimes of hypersonic flow. For inviscid flow this gives a system of conservation laws coupled with source terms representing the chemistry. Often a wide range of time scales is present in the problem, leading to numerical difficulties as in stiff systems of ordinary differential equations. Stability can be achieved by using implicit methods, but other numerical difficulties are observed. The behavior of typical numerical methods on a simple advection equation with a parameter-dependent source term was studied. Two approaches to incorporate the source term were utilized: MacCormack type predictor-corrector methods with flux limiters, and splitting methods in which the fluid dynamics and chemistry are handled in separate steps. Various comparisons over a wide range of parameter values were made. In the stiff case where the solution contains discontinuities, incorrect numerical propagation speeds are observed with all of the methods considered. This phenomenon is studied and explained.
Emergent pattern formation in an interstitial biofilm
NASA Astrophysics Data System (ADS)
Zachreson, Cameron; Wolff, Christian; Whitchurch, Cynthia B.; Toth, Milos
2017-01-01
Collective behavior of bacterial colonies plays critical roles in adaptability, survivability, biofilm expansion and infection. We employ an individual-based model of an interstitial biofilm to study emergent pattern formation based on the assumptions that rod-shaped bacteria furrow through a viscous environment and excrete extracellular polymeric substances which bias their rate of motion. Because the bacteria furrow through their environment, the substratum stiffness is a key control parameter behind the formation of distinct morphological patterns. By systematically varying this property (which we quantify with a stiffness coefficient γ ), we show that subtle changes in the substratum stiffness can give rise to a stable state characterized by a high degree of local order and long-range pattern formation. The ordered state exhibits characteristics typically associated with bacterial fitness advantages, even though it is induced by changes in environmental conditions rather than changes in biological parameters. Our findings are applicable to a broad range of biofilms and provide insights into the relationship between bacterial movement and their environment, and basic mechanisms behind self-organization of biophysical systems.
Effect of γ irradiation on the properties of basalt fiber reinforced epoxy resin matrix composite
NASA Astrophysics Data System (ADS)
Li, Ran; Gu, Yizhuo; Yang, Zhongjia; Li, Min; Wang, Shaokai; Zhang, Zuoguang
2015-11-01
Gamma-ray (γ-ray) irradiation is a crucial reason for the aging in materials used for nuclear industry. Due to high specific strength and stiffness, light weight and good corrosion resistance, fiber reinforced composites are regarded as an alternative of traditional materials used on nuclear facilities. In this study, basalt fiber (BF)/AG80 epoxy composite laminates were fabricated by autoclave process and treated with 60Co gamma irradiation dose up to 2.0 MGy. Irradiation induced polymer chain scission and oxidation of AG80 resin were detected from physical and chemical analysis. The experimental results show that the tensile and flexural performances of irradiated BF/AG80 composite maintain stable and have a low amplitude attenuation respectively, and the interlaminar shear strength has increased from irradiation dose of 0-1.5 MGy. Furthermore, the comparison between the studied BF composite and reported polymer and composite materials was done for evaluating the γ resistance property of BF composite.
NASA Astrophysics Data System (ADS)
Turner, Andrew J.; Al Rifaie, Mohammed; Mian, Ahsan; Srinivasan, Raghavan
2018-05-01
Sandwich panel structures are widely used in aerospace, marine, and automotive applications because of their high flexural stiffness, strength-to-weight ratio, good vibration damping, and low through-thickness thermal conductivity. These structures consist of solid face sheets and low-density cellular core structures, which are traditionally based upon honeycomb folded-sheet topologies. The recent advances in additive manufacturing (AM) or 3D printing process allow lattice core configurations to be designed with improved mechanical properties. In this work, the sandwich core is comprised of lattice truss structures (LTS). Two different LTS designs are 3D-printed using acrylonitrile butadiene styrene (ABS) and are tested under low-velocity impact loads. The absorption energy and the failure mechanisms of lattice cells under such loads are investigated. The differences in energy-absorption capabilities are captured by integrating the load-displacement curve found from the impact response. It is observed that selective placement of vertical support struts in the unit-cell results in an increase in the absorption energy of the sandwich panels.
Compact ultra-fast vertical nanopositioner for improving scanning probe microscope scan speed
NASA Astrophysics Data System (ADS)
Kenton, Brian J.; Fleming, Andrew J.; Leang, Kam K.
2011-12-01
The mechanical design of a high-bandwidth, short-range vertical positioning stage is described for integration with a commercial scanning probe microscope (SPM) for dual-stage actuation to significantly improve scanning performance. The vertical motion of the sample platform is driven by a stiff and compact piezo-stack actuator and guided by a novel circular flexure to minimize undesirable mechanical resonances that can limit the performance of the vertical feedback control loop. Finite element analysis is performed to study the key issues that affect performance. To relax the need for properly securing the stage to a working surface, such as a laboratory workbench, an inertial cancellation scheme is utilized. The measured dominant unloaded mechanical resonance of a prototype stage is above 150 kHz and the travel range is approximately 1.56 μm. The high-bandwidth stage is experimentally evaluated with a basic commercial SPM, and results show over 25-times improvement in the scanning performance.
Push-out tests and evaluation of FRP perfobond rib shear connectors performance
NASA Astrophysics Data System (ADS)
Kolpasky, Ludvik; Ryjacek, Pavel
2017-09-01
The behavioural characteristics of FRP (fibre-reinforced polymer) perfobond rib shear connector was examined through push-out tests in order to verify the applicability for pedestrian bridge structure. The aim of this study is to determine interaction between high performance concrete slab and handmade FRP plate which represent web of the composite beam. Combination of these modern materials leads to structural system with both great load bearing capacity and also sufficient flexural stiffness of the composite element. Openings cut into the GFRP plate at a variable spacing allow GFRP reinforcement bars to be inserted to act as shear studs. Hand lay-up process can increase suitable properties of FRP for connection by perfobond rib shear connectors. In this study, three push-out tests on fiber-reinforced polymer were performed to investigate their shear behaviour. The results of the push-out tests on FRP perfobond rib shear connector indicates great promise for application in full scale structures.
NASA Astrophysics Data System (ADS)
Turner, Andrew J.; Al Rifaie, Mohammed; Mian, Ahsan; Srinivasan, Raghavan
2018-04-01
Sandwich panel structures are widely used in aerospace, marine, and automotive applications because of their high flexural stiffness, strength-to-weight ratio, good vibration damping, and low through-thickness thermal conductivity. These structures consist of solid face sheets and low-density cellular core structures, which are traditionally based upon honeycomb folded-sheet topologies. The recent advances in additive manufacturing (AM) or 3D printing process allow lattice core configurations to be designed with improved mechanical properties. In this work, the sandwich core is comprised of lattice truss structures (LTS). Two different LTS designs are 3D-printed using acrylonitrile butadiene styrene (ABS) and are tested under low-velocity impact loads. The absorption energy and the failure mechanisms of lattice cells under such loads are investigated. The differences in energy-absorption capabilities are captured by integrating the load-displacement curve found from the impact response. It is observed that selective placement of vertical support struts in the unit-cell results in an increase in the absorption energy of the sandwich panels.
NASA Astrophysics Data System (ADS)
Mokhatar, S. N.; Sonoda, Y.; Kamarudin, A. F.; Noh, M. S. Md; Tokumaru, S.
2018-04-01
The main objective of this paper is to explore the effect of confining pressure in the compression and tension zone by simulating the behaviour of reinforced concrete/mortar structures subjected to the impact load. The analysis comprises the numerical simulation of the influences of high mass low speed impact weight dropping on concrete structures, where the analyses are incorporated with meshless method namely as Smoothed Particle Hydrodynamics (SPH) method. The derivation of the plastic stiffness matrix of Drucker-Prager (DP) that extended from Von-Mises (VM) yield criteria to simulate the concrete behaviour were presented in this paper. In which, the displacements for concrete/mortar structures are assumed to be infinitesimal. Furthermore, the influence of the different material model of DP and VM that used numerically for concrete and mortar structures are also discussed. Validation upon existing experimental test results is carried out to investigate the effect of confining pressure, it is found that VM criterion causes unreal impact failure (flexural cracking) of concrete structures.
Estimation of arterial baroreflex sensitivity in relation to carotid artery stiffness.
Lipponen, Jukka A; Tarvainen, Mika P; Laitinen, Tomi; Karjalainen, Pasi A; Vanninen, Joonas; Koponen, Timo; Lyyra-Laitinen, Tiina
2012-01-01
Arterial baroreflex has a significant role in regulating blood pressure. It is known that increased stiffness of the carotid sinus affects mecanotransduction of baroreceptors and therefore limits baroreceptors capability to detect changes in blood pressure. By using high resolution ultrasound video signal and continuous measurement of electrocardiogram (ECG) and blood pressure, it is possible to define elastic properties of artery simultaneously with baroreflex sensitivity parameters. In this paper dataset which consist 38 subjects, 11 diabetics and 27 healthy controls was analyzed. Use of diabetic and healthy test subjects gives wide scale of arteries with different elasticity properties, which provide opportunity to validate baroreflex and artery stiffness estimation methods.
Flexural phonon limited phonon drag thermopower in bilayer graphene
NASA Astrophysics Data System (ADS)
Ansari, Mohd Meenhaz; Ashraf, SSZ
2018-05-01
We investigate the phonon drag thermopower from flexural phonons as a function of electron temperature and carrier concentration in the Bloch-Gruneisen regime in non-strained bilayer graphene using Boltzmann transport equation approach. The flexural phonons are expected to be the major source of intrinsic scattering mechanism in unstrained bilayer graphene due to their large density. The flexural phonon modes dispersion relation is quadratic so these low energy flexural phonons abound at room temperature and as a result deform the bilayer graphene sheet in the out of plane direction and affects the transport properties. We also produce analytical result for phonon-drag thermopower from flexural phonons and find that phonon-drag thermopower depicts T2 dependence on temperature and n-1 on carrier concentration.
Meyer, Timothy E; Karamanoglu, Mustafa; Ehsani, Ali A; Kovács, Sándor J
2004-11-01
Impaired exercise tolerance, determined by peak oxygen consumption (VO2 peak), is predictive of mortality and the necessity for cardiac transplantation in patients with chronic heart failure (HF). However, the role of left ventricular (LV) diastolic function at rest, reflected by chamber stiffness assessed echocardiographically, as a determinant of exercise tolerance is unknown. Increased LV chamber stiffness and limitation of VO2 peak are known correlates of HF. Yet, the relationship between chamber stiffness and VO2 peak in subjects with HF has not been fully determined. Forty-one patients with HF New York Heart Association [(NYHA) class 2.4 +/- 0.8, mean +/- SD] had echocardiographic studies and VO2 peak measurements. Transmitral Doppler E waves were analyzed using a previously validated method to determine k, the LV chamber stiffness parameter. Multiple linear regression analysis of VO(2 peak) variance indicated that LV chamber stiffness k (r2 = 0.55) and NYHA classification (r2 = 0.43) were its best independent predictors and when taken together account for 59% of the variability in VO2 peak. We conclude that diastolic function at rest, as manifested by chamber stiffness, is a major determinant of maximal exercise capacity in HF.
Potential Relationship between Passive Plantar Flexor Stiffness and Running Performance.
Ueno, Hiromasa; Suga, Tadashi; Takao, Kenji; Tanaka, Takahiro; Misaki, Jun; Miyake, Yuto; Nagano, Akinori; Isaka, Tadao
2018-02-01
The present study aimed to determine the relationship between passive stiffness of the plantar flexors and running performance in endurance runners. Forty-eight well-trained male endurance runners and 24 untrained male control subjects participated in this study. Plantar flexor stiffness during passive dorsiflexion was calculated from the slope of the linear portion of the torque-angle curve. Of the endurance runners included in the present study, running economy in 28 endurance runners was evaluated by measuring energy cost during three 4-min trials (14, 16, and 18 km/h) of submaximal treadmill running. Passive stiffness of the plantar flexors was significantly higher in endurance runners than in untrained subjects. Moreover, passive plantar flexor stiffness in endurance runners was significantly correlated with a personal best 5000-m race time. Furthermore, passive plantar flexor stiffness in endurance runners was significantly correlated with energy cost during submaximal running at 16 km/h and 18 km/h, and a trend towards such significance was observed at 14 km/h. The present findings suggest that stiffer plantar flexors may help achieve better running performance, with greater running economy, in endurance runners. Therefore, in the clinical setting, passive stiffness of the plantar flexors may be a potential parameter for assessing running performance. © Georg Thieme Verlag KG Stuttgart · New York.
Bia, Daniel; Zócalo, Yanina; Farro, Ignacio; Torrado, Juan; Farro, Federico; Florio, Lucía; Olascoaga, Alicia; Brum, Javier; Alallón, Walter; Negreira, Carlos; Lluberas, Ricardo; Armentano, Ricardo L.
2011-01-01
This work was carried out in a Uruguayan (South American) population to characterize aging-associated physiological arterial changes. Parameters markers of subclinical atherosclerosis and that associate age-related changes were evaluated in healthy people. A conservative approach was used and people with nonphysiological and pathological conditions were excluded. Then, we excluded subjects with (a) cardiovascular (CV) symptoms, (b) CV disease, (c) diabetes mellitus or renal failure, and (d) traditional CV risk factors (other than age and gender). Subjects (n = 388) were submitted to non-invasive vascular studies (gold-standard techniques), to evaluate (1) common (CCA), internal, and external carotid plaque prevalence, (2) CCA intima-media thickness and diameter, (3) CCA stiffness (percentual pulsatility, compliance, distensibility, and stiffness index), (4) aortic stiffness (carotid-femoral pulse wave velocity), and (5) peripheral and central pressure wave-derived parameters. Age groups: ≤20, 21–30, 31–40, 41–50, 51–60, 61–70, and 71–80 years old. Age-related structural and functional vascular parameters profiles were obtained and analyzed considering data from other populations. The work has the strength of being the first, in Latin America, that uses an integrative approach to characterize vascular aging-related changes. Data could be used to define vascular aging and abnormal or disease-related changes. PMID:22187622
Parameter estimation for stiff deterministic dynamical systems via ensemble Kalman filter
NASA Astrophysics Data System (ADS)
Arnold, Andrea; Calvetti, Daniela; Somersalo, Erkki
2014-10-01
A commonly encountered problem in numerous areas of applications is to estimate the unknown coefficients of a dynamical system from direct or indirect observations at discrete times of some of the components of the state vector. A related problem is to estimate unobserved components of the state. An egregious example of such a problem is provided by metabolic models, in which the numerous model parameters and the concentrations of the metabolites in tissue are to be estimated from concentration data in the blood. A popular method for addressing similar questions in stochastic and turbulent dynamics is the ensemble Kalman filter (EnKF), a particle-based filtering method that generalizes classical Kalman filtering. In this work, we adapt the EnKF algorithm for deterministic systems in which the numerical approximation error is interpreted as a stochastic drift with variance based on classical error estimates of numerical integrators. This approach, which is particularly suitable for stiff systems where the stiffness may depend on the parameters, allows us to effectively exploit the parallel nature of particle methods. Moreover, we demonstrate how spatial prior information about the state vector, which helps the stability of the computed solution, can be incorporated into the filter. The viability of the approach is shown by computed examples, including a metabolic system modeling an ischemic episode in skeletal muscle, with a high number of unknown parameters.
Bia, Daniel; Zócalo, Yanina; Farro, Ignacio; Torrado, Juan; Farro, Federico; Florio, Lucía; Olascoaga, Alicia; Brum, Javier; Alallón, Walter; Negreira, Carlos; Lluberas, Ricardo; Armentano, Ricardo L
2011-01-01
This work was carried out in a Uruguayan (South American) population to characterize aging-associated physiological arterial changes. Parameters markers of subclinical atherosclerosis and that associate age-related changes were evaluated in healthy people. A conservative approach was used and people with nonphysiological and pathological conditions were excluded. Then, we excluded subjects with (a) cardiovascular (CV) symptoms, (b) CV disease, (c) diabetes mellitus or renal failure, and (d) traditional CV risk factors (other than age and gender). Subjects (n = 388) were submitted to non-invasive vascular studies (gold-standard techniques), to evaluate (1) common (CCA), internal, and external carotid plaque prevalence, (2) CCA intima-media thickness and diameter, (3) CCA stiffness (percentual pulsatility, compliance, distensibility, and stiffness index), (4) aortic stiffness (carotid-femoral pulse wave velocity), and (5) peripheral and central pressure wave-derived parameters. Age groups: ≤20, 21-30, 31-40, 41-50, 51-60, 61-70, and 71-80 years old. Age-related structural and functional vascular parameters profiles were obtained and analyzed considering data from other populations. The work has the strength of being the first, in Latin America, that uses an integrative approach to characterize vascular aging-related changes. Data could be used to define vascular aging and abnormal or disease-related changes.
Zhou, Jianting; Yan, Lei
2018-01-01
For a reinforced concrete beam subjected to fatigue loads, the structural stiffness and bearing capacity will gradually undergo irreversible degeneration, leading to damage. Moreover, there is an inherent relationship between the stiffness and bearing capacity degradation and fatigue damage. In this study, a series of fatigue tests are performed to examine the degradation law of the stiffness and bearing capacity. The results pertaining to the stiffness show that the stiffness degradation of a reinforced concrete beam exhibits a very clear monotonic decreasing "S" curve, i.e., the stiffness of the beam decreases significantly at the start of the fatigue loading, it undergoes a linear decline phase in the middle for a long loading period, and before the failure, the bearing capacity decreases drastically again. The relationship between the residual stiffness and residual bearing capacity is determined based on the assumption that the residual stiffness and residual bearing capacity depend on the same damage state, and then, the bearing capacity degradation model of the reinforced concrete beam is established based on the fatigue stiffness. Through the established model and under the premise of the known residual stiffness degradation law, the degradation law of the bearing capacity is determined by using at least one residual bearing capacity test data, for which the parameters of the stiffness degradation function are considered as material constants. The results of the bearing capacity show that the bearing capacity degradation of the reinforced concrete beam also exhibits a very clear monotonic decreasing "S" curve, which is consistent with the stiffness degradation process and in good agreement with the experiment. In this study, the stiffness and bearing capacity degradation expressions are used to quantitatively describe their occurrence in reinforced concrete beams. In particular, the expression of the bearing capacity degradation can mitigate numerous destructive tests and save cost. The stiffness and bearing capacity degradation expressions for a reinforced concrete beam can be used to predict the deformation and bearing capacity of a structure during the service process and determine the structural fatigue damage and degree of degradation. PMID:29522572
Liu, Fangping; Zhou, Jianting; Yan, Lei
2018-01-01
For a reinforced concrete beam subjected to fatigue loads, the structural stiffness and bearing capacity will gradually undergo irreversible degeneration, leading to damage. Moreover, there is an inherent relationship between the stiffness and bearing capacity degradation and fatigue damage. In this study, a series of fatigue tests are performed to examine the degradation law of the stiffness and bearing capacity. The results pertaining to the stiffness show that the stiffness degradation of a reinforced concrete beam exhibits a very clear monotonic decreasing "S" curve, i.e., the stiffness of the beam decreases significantly at the start of the fatigue loading, it undergoes a linear decline phase in the middle for a long loading period, and before the failure, the bearing capacity decreases drastically again. The relationship between the residual stiffness and residual bearing capacity is determined based on the assumption that the residual stiffness and residual bearing capacity depend on the same damage state, and then, the bearing capacity degradation model of the reinforced concrete beam is established based on the fatigue stiffness. Through the established model and under the premise of the known residual stiffness degradation law, the degradation law of the bearing capacity is determined by using at least one residual bearing capacity test data, for which the parameters of the stiffness degradation function are considered as material constants. The results of the bearing capacity show that the bearing capacity degradation of the reinforced concrete beam also exhibits a very clear monotonic decreasing "S" curve, which is consistent with the stiffness degradation process and in good agreement with the experiment. In this study, the stiffness and bearing capacity degradation expressions are used to quantitatively describe their occurrence in reinforced concrete beams. In particular, the expression of the bearing capacity degradation can mitigate numerous destructive tests and save cost. The stiffness and bearing capacity degradation expressions for a reinforced concrete beam can be used to predict the deformation and bearing capacity of a structure during the service process and determine the structural fatigue damage and degree of degradation.
Muela, Henrique Cotchi Simbo; Costa-Hong, Valeria A.; Yassuda, Monica Sanches; Machado, Michel Ferreira; Nogueira, Ricardo de Carvalho; Moraes, Natalia C.; Memória, Claudia Maia; Macedo, Thiago A.; Bor-Seng-Shu, Edson; Massaro, Ayrton Roberto; Nitrini, Ricardo; Bortolotto, Luiz A.
2017-01-01
ABSTRACT. Aging, hypertension (HTN), and other cardiovascular risk factors contribute to structural and functional changes of the arterial wall. Objective: To evaluate whether arterial stiffness (AS) is related to cerebral blood flow changes and its association with cognitive function in patients with hypertension. Methods: 211 patients (69 normotensive and 142 hypertensive) were included. Patients with hypertension were divided into 2 stages: HTN stage-1 and HTN stage-2. The mini-mental state examination (MMSE), Montreal Cognitive Assessment (MoCA) and a battery of neuropsychological (NPE) tests were used to determine cognitive function. Pulse wave velocity was measured using the Complior®. Carotid properties were assessed by radiofrequency ultrasound. Central arterial pressure and augmentation index were obtained using applanation tonometry. Middle cerebral artery flow velocity was measured by transcranial Doppler ultrasonography. Results: Both arterial stiffness parameters and cerebral vasoreactivity worsened in line with HTN severity. There was a negative correlation between breath holding index (BHI) and arterial stiffness parameters. Cognitive performance worsened in line with HTN severity, with statistical difference occurring mainly between the HTN-2 and normotension groups on both the MMSE and MoCA. The same tendency was observed on the NPE tests. Conclusion: Hypertension severity was associated with higher AS, worse BHI, and lower cognitive performance. PMID:29354219
Mass and stiffness estimation using mobile devices for structural health monitoring
NASA Astrophysics Data System (ADS)
Le, Viet; Yu, Tzuyang
2015-04-01
In the structural health monitoring (SHM) of civil infrastructure, dynamic methods using mass, damping, and stiffness for characterizing structural health have been a traditional and widely used approach. Changes in these system parameters over time indicate the progress of structural degradation or deterioration. In these methods, capability of predicting system parameters is essential to their success. In this paper, research work on the development of a dynamic SHM method based on perturbation analysis is reported. The concept is to use externally applied mass to perturb an unknown system and measure the natural frequency of the system. Derived theoretical expressions for mass and stiffness prediction are experimentally verified by a building model. Dynamic responses of the building model perturbed by various masses in free vibration were experimentally measured by a mobile device (cell phone) to extract the natural frequency of the building model. Single-degreeof- freedom (SDOF) modeling approach was adopted for the sake of using a cell phone. From the experimental result, it is shown that the percentage error of predicted mass increases when the mass ratio increases, while the percentage error of predicted stiffness decreases when the mass ratio increases. This work also demonstrated the potential use of mobile devices in the health monitoring of civil infrastructure.
Novaković, Marko; Prokšelj, Katja; Starc, Vito; Jug, Borut
2017-06-01
Adults after surgical repair of tetralogy of Fallot (ToF) may have impaired vascular and cardiac autonomic function. Thus, we wanted to assess interrelations between heart rate variability (HRV) and heart rate recovery (HRR), as parameters of cardiac autonomic function, and arterial stiffness, as a parameter of vascular function, in adults with repaired ToF as compared to healthy controls. In a case-control study of adults with repaired ToF and healthy age-matched controls we measured: 5-min HRV variability (with time and frequency domain data collected), carotid artery stiffness (through pulse-wave analysis using echo-tracking ultrasound) and post-exercise HRR (cycle ergometer exercise testing). Twenty-five patients with repaired ToF (mean age 38 ± 10 years) and 10 healthy controls (mean age 39 ± 8 years) were included. Selected HRR and HRV (time-domain) parameters, but not arterial stiffness were significantly reduced in adults after ToF repair. Moreover, a strong association between late/slow HRR (after 2, 3 and 4 min) and carotid artery stiffness was detected in ToF patients (r = -0.404, p = 0.045; r = -0.545, p = 0.005 and r = -0.545, p = 0.005, respectively), with statistical significance retained even after adjusting for age, gender, resting heart rate and β-blockers use (r = -0.393, p = 0.024 for HRR after 3 min). Autonomic cardiac function is impaired in patients with repaired ToF, and independently associated with vascular function in adults after ToF repair, but not in age-matched healthy controls. These results might help in introducing new predictors of cardiovascular morbidity in a growing population of adults after surgical repair of ToF.
Jaroch, Joanna; Łoboz-Grudzień, Krystyna; Magda, Stefania; Florescu, Maria; Bociąga, Zbigniew; Ciobanu, Andrea O; Kruszyńska, Ewa; Dudek, Krzysztof; Vinereanu, Dragos
2016-01-01
Left ventricular hypertrophy (LVH) and geometry patterns vary in different hemodynamic profiles The concentric hypertrophy (CH) pattern has been proved to have the worst prognosis. The aim of the study was to test the hypothesis that carotid artery stiffness, as a marker of vascular damage, is associated with CH, independently of other potential determinants such as demographic factors (age, sex, BMI), clinical parameters (smoking, diabetes, creatinine level) and hemodynamic variables (blood pressure, pulse pressure [PP]). The study involved 262 subjects (89 men): 202 patients with hypertension (153 untreated, 49 on medication), aged 55.7 ± 10 years, and 60 age-matched normal controls. The subjects were examined by echocardiography and carotid ultrasound with a high-resolution echo-tracking system. Based on the left ventricular mass index (LVMI) and relative wall thickness (RWT), the patients with hypertension were divided into four patterns of LVH and geometry: normal geometry (N, n = 57), concentric remodeling (CR, n = 48), concentric hypertrophy CH (n = 62) and eccentric hypertrophy (EH, n = 35). Intima-media thickness (IMT) and the parameters of arterial stiffness were also assessed using the β stiffness index (β), Young elastic modulus (Ep), arterial compliance (AC), one-point pulse wave velocity (PWVβ) and the wave reflection augmentation index (AI). Univariate analysis showed that the following variables are significant in determining CH: β > 8.4, Ep > 136 kPa, PWVβ > 7.1 m/s, AI > 21.9%, systolic BP > 151 mm Hg, PP > 54, IMT > 0.56 and the presence of diabetes. However, by multivariate analysis only AI (OR 3.65, p = 0.003), PWVβ > 7.1 m/s (OR 2.86, p = 0.014), systolic BP (OR 3.12, p = 0037) and the presence of diabetes (OR 3.75, p = 0.007) were associated independently with the occurrence of CH. Concentric hypertrophy in hypertension is strongly associated with carotid arterial stiffness and wave reflection parameters, independently of the influence of systolic blood pressure and diabetes.
Laboratory R-value vs. in-situ NDT methods.
DOT National Transportation Integrated Search
2006-05-01
The New Mexico Department of Transportation (NMDOT) uses the Resistance R-Value as a quantifying parameter in subgrade and base course design. The parameter represents soil strength and stiffness and ranges from 1 to 80, 80 being typical of the highe...
Akkan, Tolga; Altay, Mustafa; Ünsal, Yasemin; Dağdeviren, Murat; Beyan, Esin
2017-12-01
Recently, cardiovascular risk is thought to be increased in patients with nonfunctioning adrenal incidentaloma (NFAI). There are no sufficient studies in the literature to evaluate this situation in NFAI patients without cardiovascular risk. The objective of this study is to compare peripheral and central blood pressure and arterial stiffness between patients with NFAI and healthy volunteers (of a similar age, gender and body mass index as the NFAI group) who have no traditional cardiovascular risk factors and autonomous cortisol secretion, with pulse wave analysis (PWA). In this cross-sectional study, we evaluated 35 NFAI patients who have no traditional cardiovascular risk factors and 35 healthy volunteers. PWA was performed in the participants of similar gender, age and body mass index, with a Mobil-O-Graph PWA/ABPM (I.E.M. GmBH, Stolberg, Germany) device. Radiological and biochemical data were obtained retrospectively in the NFAI group. In our study, systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), central SBP, central DBP, peripheral vascular resistance, augmentation pressure (AP), heart rate-corrected augmentation index (Aix@75) and pulse wave velocity (PWV) values were significantly higher in the NFAI group compared to the control group. In addition, peripheral and central blood pressure and arterial stiffness parameters were correlated with age and duration of NFAI diagnosis of more than 1 year. NFAIs are known as cardiometabolically innocent, but in our study, both peripheral and central blood pressure values and arterial stiffness parameters were negatively affected in patients diagnosed with NFAI who have no traditional cardiovascular risk factors. These patients are at risk of cardiovascular diseases.
The flexural properties of endodontic post materials.
Stewardson, Dominic A; Shortall, Adrian C; Marquis, Peter M; Lumley, Philip J
2010-08-01
To measure the flexural strengths and moduli of endodontic post materials and to assess the effect on the calculated flexural properties of varying the diameter/length (D/L) ratio of three-point bend test samples. Three-point bend testing of samples of 2mm diameter metal and fiber-reinforced composite (FRC) rods was carried out and the mechanical properties calculated at support widths of 16 mm, 32 mm and 64 mm. Weibull analysis was performed on the strength data. The flexural strengths of all the FRC post materials exceeded the yield strengths of the gold and stainless steel samples; the flexural strengths of two FRC materials were comparable with the yield strength of titanium. Stainless steel recorded the highest flexural modulus while the titanium and the two carbon fiber materials exhibited similar values just exceeding that of gold. The remaining glass fiber materials were of lower modulus within the range of 41-57 GPa. Weibull modulus values for the FRC materials ranged from 16.77 to 30.09. Decreasing the L/D ratio produced a marked decrease in flexural modulus for all materials. The flexural strengths of FRC endodontic post materials as new generally exceed the yield strengths of metals from which endodontic posts are made. The high Weibull modulus values suggest good clinical reliability of FRC posts. The flexural modulus values of the tested posts were from 2-6 times (FRC) to 4-10 times (metal) that of dentin. Valid measurement of flexural properties of endodontic post materials requires that test samples have appropriate L/D ratios. Copyright 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Aggarwal, Ankush
2017-08-01
Motivated by the well-known result that stiffness of soft tissue is proportional to the stress, many of the constitutive laws for soft tissues contain an exponential function. In this work, we analyze properties of the exponential function and how it affects the estimation and comparison of elastic parameters for soft tissues. In particular, we find that as a consequence of the exponential function there are lines of high covariance in the elastic parameter space. As a result, one can have widely varying mechanical parameters defining the tissue stiffness but similar effective stress-strain responses. Drawing from elementary algebra, we propose simple changes in the norm and the parameter space, which significantly improve the convergence of parameter estimation and robustness in the presence of noise. More importantly, we demonstrate that these changes improve the conditioning of the problem and provide a more robust solution in the case of heterogeneous material by reducing the chances of getting trapped in a local minima. Based upon the new insight, we also propose a transformed parameter space which will allow for rational parameter comparison and avoid misleading conclusions regarding soft tissue mechanics.
Evaluation of the thermal and structural performance of straw bale construction
NASA Astrophysics Data System (ADS)
Beaudry, Kyle R.
This thesis is primarily divided into two distinct experimental programs evaluating: 1) the thermal performance and, 2) the structural performance of straw bale construction. The thermal performance chapter describes hot-box testing (based on ASTM C1363-11) of seven straw bale wall panels to obtain their apparent thermal conductivity values. All panels were constructed with stacked bales and cement-lime plaster skins on each side of the bales. Four panels were made with traditional, 2-string field bales of densities ranging from 89.5 kg/m3 - 131 kg/m3 and with the bales on-edge (fibres perpendicular to the heat flow). Three panels were made with manufactured high-density bales (291 kg/m3 - 372 kg/m3). The fibres of the manufactured bales were randomly oriented. The key conclusion of this work is that within the experimental error, there is no difference in the apparent thermal conductivity value for panels using normal density bales and manufactured high-density bales up to a density of 333 kg/m3. The structural performance chapter describes gravity and transverse load testing (based on ASTM E72-15) of non-plastered modular straw bale wall (DBW) panels to evaluate their strength capacity and failure modes. The out-of-plane flexural (OPF) tests exhibited a mean ultimate bending moment of 49.7 kNm. The axial compression (AC) tests exhibited a mean ultimate line load of 161.0 kN/m. The local flexural header beam (HP) tests exhibited an ultimate line load of 31.6 kN/m. The OPF and AC capacities of the DBW exceeded the capacities exhibited by a conventional 38 mm x 140 mm stud wall. However, the DBW's header beam strength and stiffness was inferior to conventional stud wall.
Laboratory and environmental decay of wood–plastic composite boards: flexural properties
Rebecca Ibach; Marek Gnatowski; Grace Sun; Jessie Glaeser; Mathew Leung; John Haight
2017-01-01
The flexural properties of woodâplastic composite (WPC) deck boards exposed to 9.5 years of environmental decay in Hilo, Hawaii, were compared to samples exposed to moisture and decay fungi for 12 weeks in the laboratory, to establish a correlation between sample flexural properties and calculated void volume. Specimens were tested for flexural strength and modulus,...
Mechanical properties of resin cements with different activation modes.
Braga, R R; Cesar, P F; Gonzaga, C C
2002-03-01
Dual-cured cements have been studied in terms of the hardness or degree of conversion achieved with different curing modes. However, little emphasis is given to the influence of the curing method on other mechanical properties. This study investigated the flexural strength, flexural modulus and hardness of four proprietary resin cements. Materials tested were: Enforce and Variolink II (light-, self- and dual-cured), RelyX ARC (self- and dual-cured) and C & B (self-cured). Specimens were fractured using a three-point bending test. Pre-failure loads corresponding to specific displacements of the cross-head were used for flexural modulus calculation. Knoop hardness (KHN) was measured on fragments obtained after the flexural test. Tests were performed after 24 h storage at 37 degrees C. RelyX ARC dual-cured showed higher flexural strength than the other groups. RelyX ARC and Variolink II depended upon photo-activation to achieve higher hardness values. Enforce showed similar hardness for dual- and self-curing modes. No correlation was found between flexural strength and hardness, indicating that other factors besides the degree of cure (e.g. filler content and monomer type) affect the flexural strength of composites. No statistical difference was detected in the flexural modulus among the different groups.
Improved Strength and Toughness of Carbon Woven Fabric Composites with Functionalized MWCNTs
Soliman, Eslam; Kandil, Usama; Reda Taha, Mahmoud
2014-01-01
This investigation examines the role of carboxyl functionalized multi-walled carbon nanotubes (COOH-MWCNTs) in the on- and off-axis flexure and the shear responses of thin carbon woven fabric composite plates. The chemically functionalized COOH-MWCNTs were used to fabricate epoxy nanocomposites and, subsequently, carbon woven fabric plates to be tested on flexure and shear. In addition to the neat epoxy, three loadings of COOH-MWCNTs were examined: 0.5 wt%, 1.0 wt% and 1.5 wt% of epoxy. While no significant statistical difference in the flexure response of the on-axis specimens was observed, significant increases in the flexure strength, modulus and toughness of the off-axis specimens were observed. The average increase in flexure strength and flexure modulus with the addition of 1.5 wt% COOH-MWCNTs improved by 28% and 19%, respectively. Finite element modeling is used to demonstrate fiber domination in on-axis flexure behavior and matrix domination in off-axis flexure behavior. Furthermore, the 1.5 wt% COOH-MWCNTs increased the toughness of carbon woven composites tested on shear by 33%. Microstructural investigation using Fourier Transform Infrared Spectroscopy (FTIR) proves the existence of chemical bonds between the COOH-MWCNTs and the epoxy matrix. PMID:28788698
[Properties and infiltration arts of machinable infiltration ceramic(MIC)].
Yang, H; Xian, S; Liao, Y; Xue, Y; Chai, F
2000-06-01
The purpose of this study is to explore the infiltration arts of MIC and study the effects of different packing density of Al2O3 matrix on the properties of MIC. alpha-Al2O3 specimens were fabricated by pouring alpha-Al2O3 slip with different powder/liquid ratios(P/L = 3.5, 7.5, 10.5) into a mold, and subsequently pre-fired at 1160 degrees C for 6 hours to form Al2O3 matrix. The packing density of the matrices were measured. Infiltration concepts were introduced into this study by infiltrating molten mica micro-crystalline glass into the porous Al2O3 matrix at 1160 degrees C for 6 hours to form a continuous interpenetrating composite. The composite then underwent micro-crystallization by nucleating at 550 degrees C for 1 hour and crystallizing at 900 degrees C for 1 hour, which resulted in the MIC. Mechanical properties including three point flexural strength, elastic modulus, Vicker's hardness, indentation fracture toughness and Weibull's modulus of flexural strength were determined. Parameters of machinability(H/KIC)2 of MIC were calculated. XRD and SEM were employed to study its microstructure. The resulted matrices reached packing densities of 63%, 76%, 78% with P/L of 3.5, 7.5 and 10.5. The MIC attained high strength and good machinability after infiltration. Three-point flexural strength and indentation fracture toughness were 342, 431, 374 MPa and 4.05, 4.14, 5.02 MPa m1/2 for MIC with packing density of 63%, 76%, 78% separately. And parameters of machinability were 5.41, 6.84 and 7.39 respectively. Packing density of Al2O3 matrix significantly influenced the mechanical properties. Maximum properties were obtained with a matrix packing density of 75%(P/L = 7.5), with a Weibull's modulus of flexural strength of 6.8. Machinability decreased with the increase of P/L ratio. Micro-crystallizing treatment resulted in the formation of evenly distributed mica crystalline in the composite, which contributed to the high strength of this composite material. MIC is a new infiltrated ceramic with favorable strength and machinability which can satisfy the prosthodontic requirements as all ceramic crown and bridge materials, it also shows promising outlook for future developments and clinical usage.
NASA Technical Reports Server (NTRS)
Nemeth, Michael P.; Mikulas, Martin M., Jr.
2009-01-01
Simple formulas for the buckling stress of homogeneous, specially orthotropic, laminated-composite cylinders are presented. The formulas are obtained by using nondimensional parameters and equations that facilitate general validation, and are validated against the exact solution for a wide range of cylinder geometries and laminate constructions. Results are presented that establish the ranges of the nondimensional parameters and coefficients used. General results, given in terms of the nondimensional parameters, are presented that encompass a wide range of geometries and laminate constructions. These general results also illustrate a wide spectrum of behavioral trends. Design-oriented results are also presented that provide a simple, clear indication of laminate composition on critical stress, critical strain, and axial stiffness. An example is provided to demonstrate the application of these results to thin-walled column designs.
Sensitivity-based virtual fields for the non-linear virtual fields method
NASA Astrophysics Data System (ADS)
Marek, Aleksander; Davis, Frances M.; Pierron, Fabrice
2017-09-01
The virtual fields method is an approach to inversely identify material parameters using full-field deformation data. In this manuscript, a new set of automatically-defined virtual fields for non-linear constitutive models has been proposed. These new sensitivity-based virtual fields reduce the influence of noise on the parameter identification. The sensitivity-based virtual fields were applied to a numerical example involving small strain plasticity; however, the general formulation derived for these virtual fields is applicable to any non-linear constitutive model. To quantify the improvement offered by these new virtual fields, they were compared with stiffness-based and manually defined virtual fields. The proposed sensitivity-based virtual fields were consistently able to identify plastic model parameters and outperform the stiffness-based and manually defined virtual fields when the data was corrupted by noise.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Wen-Sheng, E-mail: wsxu@uchicago.edu; Freed, Karl F., E-mail: freed@uchicago.edu; Department of Chemistry, The University of Chicago, Chicago, Illinois 60637
2015-07-14
The lattice cluster theory (LCT) for semiflexible linear telechelic melts, developed in Paper I, is applied to examine the influence of chain stiffness on the average degree of self-assembly and the basic thermodynamic properties of linear telechelic polymer melts. Our calculations imply that chain stiffness promotes self-assembly of linear telechelic polymer melts that assemble on cooling when either polymer volume fraction ϕ or temperature T is high, but opposes self-assembly when both ϕ and T are sufficiently low. This allows us to identify a boundary line in the ϕ-T plane that separates two regions of qualitatively different influence of chainmore » stiffness on self-assembly. The enthalpy and entropy of self-assembly are usually treated as adjustable parameters in classical Flory-Huggins type theories for the equilibrium self-assembly of polymers, but they are demonstrated here to strongly depend on chain stiffness. Moreover, illustrative calculations for the dependence of the entropy density of linear telechelic polymer melts on chain stiffness demonstrate the importance of including semiflexibility within the LCT when exploring the nature of glass formation in models of linear telechelic polymer melts.« less
Stiffening Sheaths for Continuum Robots.
Langer, Marlene; Amanov, Ernar; Burgner-Kahrs, Jessica
2018-06-01
Added to their high dexterity and ability to conform to complex shapes, continuum robots can be further improved to provide safer interaction with their environment. Indeed, controlling their stiffness is one of the most challenging yet promising research topics. We propose a tubular stiffening sheath as a replaceable cover for small-diameter continuum robots to temporarily increase the stiffness in a certain configuration. In this article, we assess and compare performances of two different stiffening modalities: granular and layer jamming, provide arguments for material selection and experimental results for stiffness with respect to lateral and axial applied forces. Furthermore, we detected empirically additional effects relating sheath stiffness to material parameters and added to recent investigations in the state of the art, which are based exclusively on material roughness. Finally, we integrated the selected layer jamming material in a miniaturized sheath (13 mm outer diameter, 2.5 mm wall thickness) and covered a tendon-actuated continuum robot with it. Experimental characterization of the behavior with respect to applied external forces was performed via stiffness measurements and proved that the initial tendon-actuated continuum robot stiffness can be improved by a factor up to 24.