A Linearized Model for Flicker and Contrast Thresholds at Various Retinal Illuminances
NASA Technical Reports Server (NTRS)
Ahumada, Albert; Watson, Andrew
2015-01-01
We previously proposed a flicker visibility metric for bright displays, based on psychophysical data collected at a high mean luminance. Here we extend the metric to other mean luminances. This extension relies on a linear relation between log sensitivity and critical fusion frequency, and a linear relation between critical fusion frequency and log retina lilluminance. Consistent with our previous metric, the extended flicker visibility metric is measured in just-noticeable differences (JNDs).
Potential Biological and Ecological Effects of Flickering Artificial Light
Inger, Richard; Bennie, Jonathan; Davies, Thomas W.; Gaston, Kevin J.
2014-01-01
Organisms have evolved under stable natural lighting regimes, employing cues from these to govern key ecological processes. However, the extent and density of artificial lighting within the environment has increased recently, causing widespread alteration of these regimes. Indeed, night-time electric lighting is known significantly to disrupt phenology, behaviour, and reproductive success, and thence community composition and ecosystem functioning. Until now, most attention has focussed on effects of the occurrence, timing, and spectral composition of artificial lighting. Little considered is that many types of lamp do not produce a constant stream of light but a series of pulses. This flickering light has been shown to have detrimental effects in humans and other species. Whether a species is likely to be affected will largely be determined by its visual temporal resolution, measured as the critical fusion frequency. That is the frequency at which a series of light pulses are perceived as a constant stream. Here we use the largest collation to date of critical fusion frequencies, across a broad range of taxa, to demonstrate that a significant proportion of species can detect such flicker in widely used lamps. Flickering artificial light thus has marked potential to produce ecological effects that have not previously been considered. PMID:24874801
Transfer of stimulus control from a TFT to CRT screen.
Railton, Renee Caron Richards; Foster, T Mary; Temple, William
2010-10-01
The use of television and computer screens for presenting stimuli to animals is increasing as it is non-invasive and can provide precise control over stimuli. Past studies have used cathode ray tube (CRT) screens; however, there is some evidence that these give different results to non-flickering thin film transistor (TFT) screens. Hens' critical flicker fusion frequency ranges between 80 and 90 Hz--above standard CRT screens. Thus, stimuli presented on CRT screens may appear distorted to hens. This study aimed to investigate whether changing the flicker rate of CRT screens altered hens' discrimination. Hens were trained (in a conditional discrimination) to discriminate between two stimuli on a TFT (flickerless) screen, and tested with the stimuli on a CRT screen at four flicker rates (60, 75, 85, and 100 Hz). The hens' accuracy generally decreased as the refresh rate of the CRT screen decreased. These results imply that the change in flicker rate changed the appearance of the stimuli enough to affect the hens' discrimination and stimulus control is disrupted when the stimuli appear to flicker. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Pinilla, I; Lund, R D; Sauvé, Y
2005-01-01
The Royal College of Surgeons (RCS) rat has a primary defect in retinal pigment epithelial cells that leads to the progressive loss of photoreceptors and central visual responsiveness. While most rods are lost by 90 days of age (P90), cones degenerate more slowly, and can be detected anatomically up to 2 years of age, despite massive neuronal death and retinal remodelling. To examine how this progressive degenerative process impacts on cone function, we recorded the electroretingram to white light flashes (1.37 log cd s m(-2)) presented at frequencies ranging from 3 to 50 Hz, under light adapted conditions (29.8 cd m(-2)). Pigmented dystrophic and congenic non-dystrophic RCS rats aged from 18 to 300 days were studied. In all responsive animals at all ages, maximal amplitudes were obtained at 3 Hz. In both non-dystrophic and dystrophic rats, there was an increase from P18 to P21 in response amplitude and critical fusion frequency. After P21, these two parameters declined progressively with age in dystrophic rats. Other changes included prolongation in latency, which was first detected prior to the initiation of amplitude reduction. While phase shifts were also detected in dystrophic RCS rats, they appeared at later degenerative stages. The latest age at which responses could be elicited in dystrophic rats was at P200, with positive waves being replaced by negative deflections. The effect of increments in the intensity of background illumination was tested at P50 in both groups. This caused a diminution in flicker response amplitude and critical fusion frequencies in non-dystrophics, while in dystrophic animals, response amplitudes were reduced only at low frequencies and critical fusion frequencies were unaltered. In conclusion, although dystrophic RCS rats undergo a progressive decline in cone function with age, the flicker responsiveness at P21 is comparable to that of non-dystrophic congenic rats, suggesting normal developmental maturation of the cone system in this animal model of retinal degeneration. Flicker responses can be recorded up to P200, at which point the retina has undergone severe regressive and reactive changes in its connectivity patterns. The fact that responses at this age consist of solely negative deflections might be a reflection of the highly pathological state of the retina.
2017-04-01
complementary fusion: Fourth-order Butterworth filter was used to high -pass ocelli and low-pass optic flow. The normalized cutoff frequency had to be kept...information introduced by luminance change. The high - frequency cutoff was added to reject the flickering noise for indoor usage. The filtered signals from the...function of the low- pass filter is to attenuate high - frequency noise. The final band-pass filter transfer function is in Eq. 2. (()
Toward a hybrid brain-computer interface based on repetitive visual stimuli with missing events.
Wu, Yingying; Li, Man; Wang, Jing
2016-07-26
Steady-state visually evoked potentials (SSVEPs) can be elicited by repetitive stimuli and extracted in the frequency domain with satisfied performance. However, the temporal information of such stimulus is often ignored. In this study, we utilized repetitive visual stimuli with missing events to present a novel hybrid BCI paradigm based on SSVEP and omitted stimulus potential (OSP). Four discs flickering from black to white with missing flickers served as visual stimulators to simultaneously elicit subject's SSVEPs and OSPs. Key parameters in the new paradigm, including flicker frequency, optimal electrodes, missing flicker duration and intervals of missing events were qualitatively discussed with offline data. Two omitted flicker patterns including missing black/white disc were proposed and compared. Averaging times were optimized with Information Transfer Rate (ITR) in online experiments, where SSVEPs and OSPs were identified using Canonical Correlation Analysis in the frequency domain and Support Vector Machine (SVM)-Bayes fusion in the time domain, respectively. The online accuracy and ITR (mean ± standard deviation) over nine healthy subjects were 79.29 ± 18.14 % and 19.45 ± 11.99 bits/min with missing black disc pattern, and 86.82 ± 12.91 % and 24.06 ± 10.95 bits/min with missing white disc pattern, respectively. The proposed BCI paradigm, for the first time, demonstrated that SSVEPs and OSPs can be simultaneously elicited in single visual stimulus pattern and recognized in real-time with satisfied performance. Besides the frequency features such as SSVEP elicited by repetitive stimuli, we found a new feature (OSP) in the time domain to design a novel hybrid BCI paradigm by adding missing events in repetitive stimuli.
An SSVEP-actuated brain computer interface using phase-tagged flickering sequences: a cursor system.
Lee, Po-Lei; Sie, Jyun-Jie; Liu, Yu-Ju; Wu, Chi-Hsun; Lee, Ming-Huan; Shu, Chih-Hung; Li, Po-Hung; Sun, Chia-Wei; Shyu, Kuo-Kai
2010-07-01
This study presents a new steady-state visual evoked potential (SSVEP)-based brain computer interface (BCI). SSVEPs, induced by phase-tagged flashes in eight light emitting diodes (LEDs), were used to control four cursor movements (up, right, down, and left) and four button functions (on, off, right-, and left-clicks) on a screen menu. EEG signals were measured by one EEG electrode placed at Oz position, referring to the international EEG 10-20 system. Since SSVEPs are time-locked and phase-locked to the onsets of SSVEP flashes, EEG signals were bandpass-filtered and segmented into epochs, and then averaged across a number of epochs to sharpen the recorded SSVEPs. Phase lags between the measured SSVEPs and a reference SSVEP were measured, and targets were recognized based on these phase lags. The current design used eight LEDs to flicker at 31.25 Hz with 45 degrees phase margin between any two adjacent SSVEP flickers. The SSVEP responses were filtered within 29.25-33.25 Hz and then averaged over 60 epochs. Owing to the utilization of high-frequency flickers, the induced SSVEPs were away from low-frequency noises, 60 Hz electricity noise, and eye movement artifacts. As a consequence, we achieved a simple architecture that did not require eye movement monitoring or other artifact detection and removal. The high-frequency design also achieved a flicker fusion effect for better visualization. Seven subjects were recruited in this study to sequentially input a command sequence, consisting of a sequence of eight cursor functions, repeated three times. The accuracy and information transfer rate (mean +/- SD) over the seven subjects were 93.14 +/- 5.73% and 28.29 +/- 12.19 bits/min, respectively. The proposed system can provide a reliable channel for severely disabled patients to communicate with external environments.
Individual Alpha Peak Frequency Predicts 10 Hz Flicker Effects on Selective Attention.
Gulbinaite, Rasa; van Viegen, Tara; Wieling, Martijn; Cohen, Michael X; VanRullen, Rufin
2017-10-18
Rhythmic visual stimulation ("flicker") is primarily used to "tag" processing of low-level visual and high-level cognitive phenomena. However, preliminary evidence suggests that flicker may also entrain endogenous brain oscillations, thereby modulating cognitive processes supported by those brain rhythms. Here we tested the interaction between 10 Hz flicker and endogenous alpha-band (∼10 Hz) oscillations during a selective visuospatial attention task. We recorded EEG from human participants (both genders) while they performed a modified Eriksen flanker task in which distractors and targets flickered within (10 Hz) or outside (7.5 or 15 Hz) the alpha band. By using a combination of EEG source separation, time-frequency, and single-trial linear mixed-effects modeling, we demonstrate that 10 Hz flicker interfered with stimulus processing more on incongruent than congruent trials (high vs low selective attention demands). Crucially, the effect of 10 Hz flicker on task performance was predicted by the distance between 10 Hz and individual alpha peak frequency (estimated during the task). Finally, the flicker effect on task performance was more strongly predicted by EEG flicker responses during stimulus processing than during preparation for the upcoming stimulus, suggesting that 10 Hz flicker interfered more with reactive than proactive selective attention. These findings are consistent with our hypothesis that visual flicker entrained endogenous alpha-band networks, which in turn impaired task performance. Our findings also provide novel evidence for frequency-dependent exogenous modulation of cognition that is determined by the correspondence between the exogenous flicker frequency and the endogenous brain rhythms. SIGNIFICANCE STATEMENT Here we provide novel evidence that the interaction between exogenous rhythmic visual stimulation and endogenous brain rhythms can have frequency-specific behavioral effects. We show that alpha-band (10 Hz) flicker impairs stimulus processing in a selective attention task when the stimulus flicker rate matches individual alpha peak frequency. The effect of sensory flicker on task performance was stronger when selective attention demands were high, and was stronger during stimulus processing and response selection compared with the prestimulus anticipatory period. These findings provide novel evidence that frequency-specific sensory flicker affects online attentional processing, and also demonstrate that the correspondence between exogenous and endogenous rhythms is an overlooked prerequisite when testing for frequency-specific cognitive effects of flicker. Copyright © 2017 the authors 0270-6474/17/3710173-12$15.00/0.
Effects Of Local Oscillator Errors On Digital Beamforming
2016-03-01
processor EF element factor EW electronic warfare FFM flicker frequency modulation FOV field-of-view FPGA field-programmable gate array FPM flicker...frequencies and also more difficult to measure [15]. 2. Flicker frequency modulation The source for flicker frequency modulation ( FFM ) is attributed to...a physical resonance mechanism of an oscillator or issues controlling electronic components. Some oscillators might not show FFM noise, which might
No attentional capture from invisible flicker
Alais, David; Locke, Shannon M.; Leung, Johahn; Van der Burg, Erik
2016-01-01
We tested whether fast flicker can capture attention using eight flicker frequencies from 20–96 Hz, including several too high to be perceived (>50 Hz). Using a 480 Hz visual display rate, we presented smoothly sampled sinusoidal temporal modulations at: 20, 30, 40, 48, 60, 69, 80, and 96 Hz. We first established flicker detection rates for each frequency. Performance was at or near ceiling until 48 Hz and dropped sharply to chance level at 60 Hz and above. We then presented the same flickering stimuli as pre-cues in a visual search task containing five elements. Flicker location varied randomly and was therefore congruent with target location on 20% of trials. Comparing congruent and incongruent trials revealed a very strong congruency effect (faster search for cued targets) for all detectable frequencies (20–48 Hz) but no effect for faster flicker rates that were detected at chance. This pattern of results (obtained with brief flicker cues: 58 ms) was replicated for long flicker cues (1000 ms) intended to allow for entrainment to the flicker frequency. These results indicate that only visible flicker serves as an exogenous attentional cue and that flicker rates too high to be perceived are completely ineffective. PMID:27377759
Al-Kuraishy, Hayder M
2016-01-01
The present study investigates the effect of combined treatment with Ginkgo biloba and/or Rhodiola rosea on psychomotor vigilance task (PVT) and short-term working memory accuracy. A total number of 112 volunteers were enrolled to study the effect of G. biloba and R. rosea on PVT and short-term working memory accuracy as compared to placebo effects, the central cognitive effect was assessed by critical flicker-fusion frequency, PVT, and computerized N-back test. Placebo produced no significant effects on all neurocognitive tests measure P > 0.05 in normal healthy volunteers, G. biloba or R. rosea improve PVT and low to moderate working memory accuracy, The combined effect of R. rosea and G. biloba leading to more significant effect on PVT, all levels of short-term working memory accuracy and critical fusion versus flicker P < 0.01, more than of G. biloba or R. rosea when they used alone. The combined effect of R. rosea and G. biloba leading to a more significant effect on cognitive function than either G. biloba or R. rosea when they used alone.
Which lamp will be optimum to eye? Incandescent, fluorescent or LED etc
Chen, Liang; Zhang, Xiao-Wei
2014-01-01
Low frequency flicker, high frequency flicker, strong light, strong blue light, infrared, ultraviolet, electromagnetic radiation, ripple flicker and dimming flicker produced by different lamps have negative impact on vision, eyes and health. Negative impact on eyes resulting in myopia or cataract etc: the solution is to remove all the negative factors by applying upright lighting technology and that is optimum to vision, eyes and health. PMID:24634884
Which lamp will be optimum to eye? Incandescent, fluorescent or LED etc.
Chen, Liang; Zhang, Xiao-Wei
2014-01-01
Low frequency flicker, high frequency flicker, strong light, strong blue light, infrared, ultraviolet, electromagnetic radiation, ripple flicker and dimming flicker produced by different lamps have negative impact on vision, eyes and health. Negative impact on eyes resulting in myopia or cataract etc: the solution is to remove all the negative factors by applying upright lighting technology and that is optimum to vision, eyes and health.
Fuentes, Juan P; Villafaina, Santos; Collado-Mateo, Daniel; de la Vega, Ricardo; Gusi, Narcis; Clemente-Suárez, Vicente Javier
2018-01-19
Psychophysiological requirements of chess players are poorly understood, and periodization of training is often made without any empirical basis. For this reason, the aim of the present study was to investigate the psychophysiological response and quantify the player internal load during, and after playing a chess game. The participant was an elite 33 year-old male chess player ranked among the 300 best chess players in the world. Thus, cortical arousal by critical flicker fusion threshold, electroencephalogram by the theta Fz/alpha Pz ratio and autonomic modulation by heart rate variability were analyzed. Data revealed that cortical arousal by critical flicker fusion threshold and theta Fz/alpha Pz ratio increased and heart rate variability decreased during chess game. All these changes indicated that internal load increased during the chess game. In addition, pre-activation was detected in pre-game measure, suggesting that the prefrontal cortex might be preparatory activated. For these reasons, electroencephalogram, critical flicker fusion threshold and heart rate variability analysis may be highly applicable tools to control and monitor workload in chess player.
Time sequence analysis of flickering auroras. I - Application of Fourier analysis. [in atmosphere
NASA Technical Reports Server (NTRS)
Berkey, F. T.; Silevitch, M. B.; Parsons, N. R.
1980-01-01
Using a technique that enables one to digitize the brightness of auroral displays from individual fields of a video signal, we have analyzed the frequency content of flickering aurora. Through the application of Fourier analysis to our data, we have found that flickering aurora contains a wide range of enhanced frequencies, although the dominant frequency enhancement generally occurs in the range 6-12 Hz. Each incidence of flickering that we observed was associated with increased radio wave absorption. Furthermore, we have found that flickering occurs in bright auroral surges, the occurrence of which is not limited to the 'breakup' phase of auroral substorms. Our results are interpreted in terms of a recently proposed theory of fluctuating double layers that accounts for a number of the observational features.
Fireball flickering: the case for indirect measurement of meteoroid rotation rates
NASA Astrophysics Data System (ADS)
Beech, Martin; Brown, Peter
2000-08-01
Data collected during the Meteorite Observation and Recovery Program (MORP) indicate that 4% of bright fireballs show a periodic variation or flickering in brightness. The observed flickering frequencies vary from a few Hz to as high as 500 Hz. We interpret the flickering phenomenon in terms of meteoroid rotation. The MORP data does not reveal any apparent correlation between the flickering frequency and the properties of the meteoroid or the atmospheric flow conditions under which ablation is taking place. It is argued that the most likely cause of the flickering phenomenon is the rotational modulation of the cross-section area presented by the meteoroid to the on-coming airflow. A study is made of the Peekskill fireball and it is concluded that the meteoroid was spun-up during its long flight through the Earth's atmosphere, and that its initial brake up was due to rotational bursting. We also argue that the Peekskill event provides the best observational evidence that the flickering phenomenon is truly related to the rotation rate of the impinging meteoroid. We find that the observed rotation rates of the MORP fireballs are clustered just below the allowed limit set by rotational bursting, but argue that this is due to an observational selection effect that mitigates against the detection of low-frequency flickering.
Sabbah, Shai; Hawryshyn, Craig W
2013-07-04
Two competing theories have been advanced to explain the evolution of multiple cone classes in vertebrate eyes. These two theories have important, but different, implications for our understanding of the design and tuning of vertebrate visual systems. The 'contrast theory' proposes that multiple cone classes evolved in shallow-water fish to maximize the visual contrast of objects against diverse backgrounds. The competing 'flicker theory' states that multiple cone classes evolved to eliminate the light flicker inherent in shallow-water environments through antagonistic neural interactions, thereby enhancing object detection. However, the selective pressures that have driven the evolution of multiple cone classes remain largely obscure. We show that two critical assumptions of the flicker theory are violated. We found that the amplitude and temporal frequency of flicker vary over the visible spectrum, precluding its cancellation by simple antagonistic interactions between the output signals of cones. Moreover, we found that the temporal frequency of flicker matches the frequency where sensitivity is maximal in a wide range of fish taxa, suggesting that the flicker may actually enhance the detection of objects. Finally, using modeling of the chromatic contrast between fish pattern and background under flickering illumination, we found that the spectral sensitivity of cones in a cichlid focal species is optimally tuned to maximize the visual contrast between fish pattern and background, instead of to produce a flicker-free visual signal. The violation of its two critical assumptions substantially undermines support for the flicker theory as originally formulated. While this alone does not support the contrast theory, comparison of the contrast and flicker theories revealed that the visual system of our focal species was tuned as predicted by the contrast theory rather than by the flicker theory (or by some combination of the two). Thus, these findings challenge key assumptions of the flicker theory, leaving the contrast theory as the most parsimonious and tenable account of the evolution of multiple cone classes.
Effect of a single dose of dextromethorphan on psychomotor performance and working memory capacity.
Al-Kuraishy, Hayder M; Al-Gareeb, Ali I; Ashor, Ammar Waham
2012-04-01
Previous studies show that the prolonged use of dextromethorphan produces cognitive deterioration in humans. The aim of this study was to investigate the effect of a single dose of dextroemthrophan on psychomotor performance and working memory capacity. This is a randomized, double-blind, controlled, and prospective study. Thirty-six (17 women, 19 men) medical students enrolled in the study; half of them (7 women, 11 men) were given placebo, while the other half (10 women, 8 men) received dextromethorphan. The choice reaction time, critical flicker fusion threshold, and N-back working memory task were measured before and after 2 h of taking the drugs. Dextromethorphan showed a significant deterioration in the 3-back working memory task (P<0.05). No significant changes were seen as regards the choice reaction time components (total, recognition, motor) and critical flicker fusion threshold (P>0.05). On the other hand, placebo showed no significant changes as regards the choice reaction time, critical flicker fusion threshold, and N-back working memory task (P>0.05). A single dose of dextromethorphan has no effect on attention and arousal but may significantly impair the working memory capacity.
Gregori, Bruno; Papazachariadis, Odysseas; Farruggia, Alfonsa; Accornero, Neri
2011-01-15
Optic neuritis related to multiple sclerosis and diabetic retinopathy are relatively selective post-retinal and retinal vision disorders. Vision impairment in both conditions is reliably measured by testing critical fusion frequency (CFF). To examine color vision, we measured the CFF in response to red and blue stimuli, and tested CFF values in patients without evident vision impairment. To ensure that differences in CFF values in a given subject depended only on color perception we displayed red and blue flickering stimuli at equal luminance. CFF to red or blue stimuli were compared in patients with medical history of optic neuritis related to multiple sclerosis (post-retinal vision impairment), patients with diabetic retinopathy (retinal vision impairment) and healthy subjects. The test procedure disclosed altered CFF values for red and blue stimuli in both groups of patients studied. The comparison between the two groups disclosed a prevalent CFF impairment for red stimuli in patients with optic neuritis related to multiple sclerosis and for blue stimuli in patients with diabetic retinopathy. The differential color flicker test appears highly accurate in detecting color vision impairment. Comparison of the two color CFFs differentiates retinal from post-retinal visual disorders. Copyright © 2010 Elsevier B.V. All rights reserved.
Fiesta, Matthew P; Eagleman, David M
2008-09-15
As the frequency of a flickering light is increased, the perception of flicker is replaced by the perception of steady light at what is known as the critical flicker fusion threshold (CFFT). This threshold provides a useful measure of the brain's information processing speed, and has been used in medicine for over a century both for diagnostic and drug efficacy studies. However, the hardware for presenting the stimulus has not advanced to take advantage of computers, largely because the refresh rates of typical monitors are too slow to provide fine-grained changes in the alternation rate of a visual stimulus. For example, a cathode ray tube (CRT) computer monitor running at 100Hz will render a new frame every 10 ms, thus restricting the period of a flickering stimulus to multiples of 20 ms. These multiples provide a temporal resolution far too low to make precise threshold measurements, since typical CFFT values are in the neighborhood of 35 ms. We describe here a simple and novel technique to enable alternating images at several closely-spaced periods on a standard monitor. The key to our technique is to programmatically control the video card to dynamically reset the refresh rate of the monitor. Different refresh rates allow slightly different frame durations; this can be leveraged to vastly increase the resolution of stimulus presentation times. This simple technique opens new inroads for experiments on computers that require more finely-spaced temporal resolution than a monitor at a single, fixed refresh rate can allow.
EEG-based usability assessment of 3D shutter glasses.
Wenzel, Markus A; Schultze-Kraft, Rafael; Meinecke, Frank C; Fabien Cardinaux; Kemp, Thomas; Klaus-Robert Müller; Gabriel Curio; Benjamin Blankertz
2016-02-01
Neurotechnology can contribute to the usability assessment of products by providing objective measures of neural workload and can uncover usability impediments that are not consciously perceived by test persons. In this study, the neural processing effort imposed on the viewer of 3D television by shutter glasses was quantified as a function of shutter frequency. In particular, we sought to determine the critical shutter frequency at which the 'neural flicker' vanishes, such that visual fatigue due to this additional neural effort can be prevented by increasing the frequency of the system. Twenty-three participants viewed an image through 3D shutter glasses, while multichannel electroencephalogram (EEG) was recorded. In total ten shutter frequencies were employed, selected individually for each participant to cover the range below, at and above the threshold of flicker perception. The source of the neural flicker correlate was extracted using independent component analysis and the flicker impact on the visual cortex was quantified by decoding the state of the shutter from the EEG. Effects of the shutter glasses were traced in the EEG up to around 67 Hz-about 20 Hz over the flicker perception threshold-and vanished at the subsequent frequency level of 77 Hz. The impact of the shutter glasses on the visual cortex can be detected by neurotechnology even when a flicker is not reported by the participants. Potential impact. Increasing the shutter frequency from the usual 50 Hz or 60 Hz to 77 Hz reduces the risk of visual fatigue and thus improves shutter-glass-based 3D usability.
Contrast affects flicker and speed perception differently
NASA Technical Reports Server (NTRS)
Thompson, P.; Stone, L. S.
1997-01-01
We have previously shown that contrast affects speed perception, with lower-contrast, drifting gratings perceived as moving slower. In a recent study, we examined the implications of this result on models of speed perception that use the amplitude of the response of linear spatio-temporal filters to determine speed. In this study, we investigate whether the contrast dependence of speed can be understood within the context of models in which speed estimation is made using the temporal frequency of the response of linear spatio-temporal filters. We measured the effect of contrast on flicker perception and found that contrast manipulations produce opposite effects on perceived drift rate and perceived flicker rate, i.e., reducing contrast increases the apparent temporal frequency of counterphase modulated gratings. This finding argues that, if a temporal frequency-based algorithm underlies speed perception, either flicker and speed perception must not be based on the output of the same mechanism or contrast effects on perceived spatial frequency reconcile the disparate effects observed for perceived temporal frequency and speed.
Grandjean, E
1979-01-01
Physical fatigue is a painful phenomenon which is localised in overstressed muscles. Mental fatigue is a diffuse sensation of weariness; it is a functional state, one of several intermediate conditions between the two extremes of alarm and sleep. A neurophysiological model of fatigue, involving an activating and inhibitory system has been developed. Fatigue in industrial practice has clinical symptoms: psychic instability, fits of depression and increased liability to illness. Indicators of fatigue are work of performance, subjective feelings of fatigue, electroencephalography, flicker-fusion frequency and various psychomotor and mental tests. Several field studies do, to some extent, confirm the above-mentioned concept of fatigue. PMID:40999
Hashimoto, Yuki; Yotsumoto, Yuko
2018-01-01
The neural basis of time perception has long attracted the interests of researchers. Recently, a conceptual model consisting of neural oscillators was proposed and validated by behavioral experiments that measured the dilated duration in perception of a flickering stimulus (Hashimoto and Yotsumoto, 2015). The model proposed that flickering stimuli cause neural entrainment of oscillators, resulting in dilated time perception. In this study, we examined the oscillator-based model of time perception, by collecting electroencephalography (EEG) data during an interval-timing task. Initially, subjects observed a stimulus, either flickering at 10-Hz or constantly illuminated. The subjects then reproduced the duration of the stimulus by pressing a button. As reported in previous studies, the subjects reproduced 1.22 times longer durations for flickering stimuli than for continuously illuminated stimuli. The event-related potential (ERP) during the observation of a flicker oscillated at 10 Hz, reflecting the 10-Hz neural activity phase-locked to the flicker. Importantly, the longer reproduced duration was associated with a larger amplitude of the 10-Hz ERP component during the inter-stimulus interval, as well as during the presentation of the flicker. The correlation between the reproduced duration and the 10-Hz oscillation during the inter-stimulus interval suggested that the flicker-induced neural entrainment affected time dilation. While the 10-Hz flickering stimuli induced phase-locked entrainments at 10 Hz, we also observed event-related desynchronizations of spontaneous neural oscillations in the alpha-frequency range. These could be attributed to the activation of excitatory neurons while observing the flicker stimuli. In addition, neural activity at approximately the alpha frequency increased during the reproduction phase, indicating that flicker-induced neural entrainment persisted even after the offset of the flicker. In summary, our results suggest that the duration perception is mediated by neural oscillations, and that time dilation induced by flickering visual stimuli can be attributed to neural entrainment.
Vision-related quality of life after transsphenoidal surgery for pituitary adenoma.
Okamoto, Yoshifumi; Okamoto, Fumiki; Yamada, Shozo; Honda, Maiko; Hiraoka, Takahiro; Oshika, Tetsuro
2010-07-01
PURPOSE. To use the 25-item National Eye Institute Visual Function Questionnaire (VFQ-25) to evaluate vision-related quality of life (VR-QOL) in patients with pituitary adenoma who undergo transsphenoidal surgery. METHODS. The VFQ-25 was self-administered by 74 patients with pituitary adenoma before and 3 months after surgery. Pre- and postoperative clinical data were collected, including age, sex, tumor type and size, logarithm of minimum angle of resolution best corrected visual acuity (logMAR BCVA), critical flicker fusion frequency, static perimetry scores (mean deviation [MD] and corrected pattern SD [CPSD]), duration of ocular symptoms, and number of systemic comorbidities. RESULTS. Seventy-four patients with a mean age of 48.2 years were studied. Transsphenoidal surgery for pituitary adenoma significantly improved logMAR BCVA and critical fusion flicker frequency in the worse-seeing eye and MD and CPSD scores in both the better- and worse-seeing eyes (P < 0.001). The VFQ-25 composite score and all subscale scores, except those for the general health and color vision subscales, improved significantly (P < 0.05). A multivariate regression analysis revealed that the preoperative VFQ-25 composite score and the preoperative MD and CPSD scores in the better-seeing eye were related to the postoperative VFQ-25 composite score (P < 0.05). CONCLUSIONS. This study quantitatively demonstrated that transsphenoidal surgery can dramatically improve VR-QOL in pituitary adenoma and that the preoperative VFQ-25 composite score and visual field disturbance in the better-seeing eye are particularly important predictors associated with the postoperative VR-QOL. The use of VFQ-25 provides a more comprehensive overview of the effectiveness of transsphenoidal surgery.
Metabolic rate and body size are linked with perception of temporal information☆
Healy, Kevin; McNally, Luke; Ruxton, Graeme D.; Cooper, Natalie; Jackson, Andrew L.
2013-01-01
Body size and metabolic rate both fundamentally constrain how species interact with their environment, and hence ultimately affect their niche. While many mechanisms leading to these constraints have been explored, their effects on the resolution at which temporal information is perceived have been largely overlooked. The visual system acts as a gateway to the dynamic environment and the relative resolution at which organisms are able to acquire and process visual information is likely to restrict their ability to interact with events around them. As both smaller size and higher metabolic rates should facilitate rapid behavioural responses, we hypothesized that these traits would favour perception of temporal change over finer timescales. Using critical flicker fusion frequency, the lowest frequency of flashing at which a flickering light source is perceived as constant, as a measure of the maximum rate of temporal information processing in the visual system, we carried out a phylogenetic comparative analysis of a wide range of vertebrates that supported this hypothesis. Our results have implications for the evolution of signalling systems and predator–prey interactions, and, combined with the strong influence that both body mass and metabolism have on a species' ecological niche, suggest that time perception may constitute an important and overlooked dimension of niche differentiation. PMID:24109147
DOT National Transportation Integrated Search
1985-10-01
The present study examined the effect of differing levels of visual taskload on critical flicker frequency (CFF) change during performance of a complex monitoring task. The task employed was designed to functionally simulate the general task characte...
Oh, Seung-Won; Park, Jun-Hee; Lee, Ji-Hoon; Yoon, Tae-Hoon
2015-09-07
Recently, low-frequency driving of liquid crystal display (LCD) panels to minimize power consumption has drawn much attention. In the case in which an LCD panel is driven by a fringe-field at a low frequency, the image flickering phenomenon occurs when the sign of the applied electric field is reversed. We investigated image flickering induced by the flexoelectric effect in a fringe-field switching (FFS) liquid crystal cell in terms of the transmittance difference between frames and the ripple phenomenon. Experimental results show that image flicker due to transmittance difference can be eliminated completely and that the ripple phenomena can be reduced significantly by applying a bipolar voltage wave to the FFS cell.
NASA Astrophysics Data System (ADS)
Oh, Seung-Won; Baek, Jong-Min; Kim, Jung-Wook; Yoon, Tae-Hoon
2016-09-01
Two types of image flicker, which are caused by the flexoelectric effect of liquid crystals (LCs), are observed when a fringe-field switching (FFS) LC cell is driven by a low frequency electric field. Static image flicker, observed because of the transmittance difference between neighboring frames, has been reported previously. On the other hand, research on dynamic image flicker has been minimal until now. Dynamic image flicker is noticeable because of the brief transmittance drop when the sign of the applied voltage is reversed. We investigated the dependence of the image flicker in an FFS LC cell on dielectric anisotropy of the LCs in terms of both the static and dynamic flicker. Experimental results show that small dielectric anisotropy of the LC can help suppress not only the static but also dynamic flicker for positive LCs. We found that both the static and dynamic flicker in negative LCs is less evident than in positive LCs.
CRITICAL ILLUMINATION AND FLICKER FREQUENCY IN RELATED FISHES
Crozier, W. J.; Wolf, E.; Zerrahn-Wolf, Gertrud
1937-01-01
Flicker response curves have been obtained at 21.5°C. for three genera of fresh water teleosts: Enneacanthus (sunfish), Xiphophorus (swordtail), Platypoecilius (Platy), by the determination of mean critical intensities for response at fixed flicker frequencies, and for a certain homogeneous group of backcross hybrids of swordtail x Platy (Black Helleri). The curves exhibit marked differences in form and proportions. The same type of analysis is applicable to each, however. A low intensity rod-governed section has added to it a more extensive cone portion. Each part is accurately described by the equation F = Fmax./(1 + e -p log-p logI/Ii), where F = flicker frequency, I = associated mean critical intensity, and Ii is the intensity at the inflection point of the sigmoid curve relating F to log I. There is no correlation between quantitative features of the rod and cone portions. Threshold intensities, p, Ii, and Fmax. are separately and independently determined. The hybrid Black Helleri show quantitative agreement with the Xiphophorus parental stock in the values of p for rods and cones, and in the cone Fmax.; the rod Fmax. is very similar to that for the Platy stock; the general level of effective intensities is rather like that of the Platy form. This provides, among other things, a new kind of support for the duplicity doctrine. Various races of Platypoecilius maculatus, and P. variatus, give closely agreeing values of Im at different flicker frequencies; and two species of sunfish also agree. The effect of cross-breeding is thus not a superficial thing. It indicates the possibility of further genetic investigation. The variability of the critical intensity for response to flicker follows the rules previously found to hold for other forms. The variation is the expression of a property of the tested organism. It is shown that, on the assumption of a frequency distribution of receptor element thresholds as a function of log I, with fluctuation in the excitabilities of the marginally excited elements, it is to be expected that the dispersion of critical flicker frequencies in repeated measurements will pass through a maximum as log I is increased, whereas the dispersion of critical intensities will be proportional to Im; and that the proportionality factor in the case of different organisms bears no relation to the form or position of the respective curves relating mean critical intensity to flicker frequency. These deductions agree with the experimental findings. PMID:19873037
Flicker parameters are different for suppression of myopia and hyperopia.
Schwahn, H N; Schaeffel, F
1997-10-01
Axial eye growth rates in the chicken are controlled by local retinal image-processing circuits. These circuits quantify the loss of contrast for different spatial frequencies and promote axial eye growth rates in correlation with the amount of retinal image degradation ("deprivation myopia"). They also distinguish whether the plane of focus lies in front of or behind the retina. How the sign of defocus is detected still remains unclear. Cues from chromatic aberration are not important. In an attempt to isolate retinal circuits controlling the development of myopia or hyperopia, young chickens were raised in flickering light of different frequencies (12 and 6 Hz) and duty cycles (4-75%) produced by rotating chopper disks. The effects of flickering light on refractive errors and change in axial growth rates induced by translucent occluders or defocusing lenses were measured by infrared retinoscopy and A-scan ultrasound, respectively. Retinal electrical activity was evaluated by flicker ERG after matching flicker parameters and stimulation brightness at retinal surface. Changes in retinal and vitreal dopamine content caused by flicker in occluded and normal eyes were determined by HPLC-ECD. Strikingly, suppression of myopia occurred for similar flicker parameters, whether induced by translucent occluders ("deprivation") or negative lenses ("defocus"). The degree to which myopia was suppressed was correlated with the duration of flicker dark phase and with the ERG amplitude. In contrast, suppression of hyperopia did not correlate with these parameters. We conclude that two different retinal circuits with different temporal characteristics are involved in the processing of hyperopic defocus/deprivation and of myopic defocus, the first one dependent on flicker ERG amplitude. However, we did not find any correlation between the rate of dopamine release and the degree of inhibition of deprivation myopia in flickering light.
EEG-based usability assessment of 3D shutter glasses
NASA Astrophysics Data System (ADS)
Wenzel, Markus A.; Schultze-Kraft, Rafael; Meinecke, Frank C.; Cardinaux, Fabien; Kemp, Thomas; Müller, Klaus-Robert; Curio, Gabriel; Blankertz, Benjamin
2016-02-01
Objective. Neurotechnology can contribute to the usability assessment of products by providing objective measures of neural workload and can uncover usability impediments that are not consciously perceived by test persons. In this study, the neural processing effort imposed on the viewer of 3D television by shutter glasses was quantified as a function of shutter frequency. In particular, we sought to determine the critical shutter frequency at which the ‘neural flicker’ vanishes, such that visual fatigue due to this additional neural effort can be prevented by increasing the frequency of the system. Approach. Twenty-three participants viewed an image through 3D shutter glasses, while multichannel electroencephalogram (EEG) was recorded. In total ten shutter frequencies were employed, selected individually for each participant to cover the range below, at and above the threshold of flicker perception. The source of the neural flicker correlate was extracted using independent component analysis and the flicker impact on the visual cortex was quantified by decoding the state of the shutter from the EEG. Main Result. Effects of the shutter glasses were traced in the EEG up to around 67 Hz—about 20 Hz over the flicker perception threshold—and vanished at the subsequent frequency level of 77 Hz. Significance. The impact of the shutter glasses on the visual cortex can be detected by neurotechnology even when a flicker is not reported by the participants. Potential impact. Increasing the shutter frequency from the usual 50 Hz or 60 Hz to 77 Hz reduces the risk of visual fatigue and thus improves shutter-glass-based 3D usability.
Mechanisms of Photophobia in Mild Traumatic Brain Injury in Human Subjects: Therapeutic Implications
2015-10-01
R, G, B and W). FMRI Stimuli The four fMRI runs consisted of 6 cycles of: 1. 20 s of 2.5 Hz Blue/Black Flicker alternating with 20 s Steady Black...7 2. 20 s of 2.5 Hz Red/Black Flicker , alternating with 20 s Steady Black 3. 20 s of Steady Blue alternating with 20 s Steady Red 4. 20 s of Steady...Blue alternating with 20 s Steady Green The preliminary studies confirmed that we can set all flicker frequencies at 2.5Hz to match the frequency used
The role of amplitude-to-phase conversion in the generation of oscillator flicker phase noise
NASA Technical Reports Server (NTRS)
Hearn, C. P.
1985-01-01
The role of amplitude-to-phase conversion as a factor in feedback oscillator flicker phase noise is examined. A limiting stage consisting of parallel-connected opposite polarity diodes operating in a circuit environment contining reactance is shown to exhibit amplitude-to-phase conversion. This mechanism coupled with resistive upconversion provides an indirect route for very low frequency flicker noise to be transferred into the phase of an oscillator signal. It is concluded that this effect is more significant in the lower frequency regimes where the onlinear reactances associated with active devices are overwhelmed by linear reactive elements.
Hindmarch, I.; Parrott, A. C.
1977-01-01
1 Nine normal subjects volunteered to participate in a randomized single-blind crossover study of nomifensine 75 mg and two comparators, imipramine 75 mg and placebo. 2 Each volunteer received placebo for 3 d, then the first test drug for 4 days. This sequence was repeated twice more, so that each subject received each comparator. All medication was taken three times daily. 3 Assessments were made on days 3, 5 and 7 of each sequence, and consisted of a Sleep Evaluation Questionnaire, a test of Critical Flicker Fusion and a measurement of Complex Reaction Time (CRT). 4 There were no significant differences in the CRT. There was a significant increase in critical flicker fusion with nomifensine. 5 Although both nomifensine and imipramine disturbed the quality of sleep, only imipramine produced a hangover. PMID:334219
Flicker in a twisted nematic spatial light modulator
NASA Astrophysics Data System (ADS)
Calderón-Hermosillo, Yuliana; García-Márquez, Jorge; Espinosa-Luna, Rafael; Ochoa, Noé Alcalá; López, Víctor; Aguilar, Alberto; Noé-Arias, Enrique; Alayli, Yasser
2013-06-01
Liquid Crystal on Silicon (LCoS) Spatial Light Modulators (SLM) are widely used for their capability to control beams howbeit fluctuations in phase and amplitude. It is then necessary to understand the negative effects of these fluctuations, also known as flicker, and the means to mitigate them. The flicker is observed either as high frequency variations of polarization, attenuation or high phase fluctuations on the wave front modulated by the LCoS device. Here, we compare the flicker behavior in a twisted nematic (TN) LCoS-SLM for different polarization schemes and temperatures. The quantitative evaluation shows that flicker is effectively reduced only by chilling the LCoS panel to temperatures just below 0 °C but, the LCoS modulation capability is also affected.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamanishi, Masamichi, E-mail: masamiya@crl.hpk.co.jp; Hirohata, Tooru; Hayashi, Syohei
2014-11-14
Free running line-widths (>100 kHz), much broader than intrinsic line-widths ∼100 Hz, of existing quantum-cascade lasers are governed by strong flicker frequency-noise originating from electrical flicker noise. Understanding of microscopic origins of the electrical flicker noises in quantum-cascade lasers is crucially important for the reduction of strength of flicker frequency-noise without assistances of any type of feedback schemes. In this article, an ad hoc model that is based on fluctuating charge-dipoles induced by electron trappings and de-trappings at indispensable impurity states in injector super-lattices of a quantum-cascade laser is proposed, developing theoretical framework based on the model. The validity of the presentmore » model is evaluated by comparing theoretical voltage-noise power spectral densities based on the model with experimental ones obtained by using mid-infrared quantum-cascade lasers with designed impurity-positioning. The obtained experimental results on flicker noises, in comparison with the theoretical ones, shed light on physical mechanisms, such as the inherent one due to impurity states in their injectors and extrinsic ones due to surface states on the ridge-walls and due to residual deep traps, for electrical flicker-noise generation in existing mid-infrared quantum-cascade lasers. It is shown theoretically that quasi-delta doping of impurities in their injectors leads to strong suppression of electrical flicker noise by minimization of the dipole length at a certain temperature, for instance ∼300 K and, in turn, is expected to result in substantial narrowing of the free running line-width down below 10 kHz.« less
A new frequency approach for light flicker evaluation in electric power systems
NASA Astrophysics Data System (ADS)
Feola, Luigi; Langella, Roberto; Testa, Alfredo
2015-12-01
In this paper, a new analytical estimator for light flicker in frequency domain, which is able to take into account also the frequency components neglected by the classical methods proposed in literature, is proposed. The analytical solutions proposed apply for any generic stationary signal affected by interharmonic distortion. The light flicker analytical estimator proposed is applied to numerous numerical case studies with the goal of showing i) the correctness and the improvements of the analytical approach proposed with respect to the other methods proposed in literature and ii) the accuracy of the results compared to those obtained by means of the classical International Electrotechnical Commission (IEC) flickermeter. The usefulness of the proposed analytical approach is that it can be included in signal processing tools for interharmonic penetration studies for the integration of renewable energy sources in future smart grids.
Frequency-dependent tACS modulation of BOLD signal during rhythmic visual stimulation.
Chai, Yuhui; Sheng, Jingwei; Bandettini, Peter A; Gao, Jia-Hong
2018-05-01
Transcranial alternating current stimulation (tACS) has emerged as a promising tool for modulating cortical oscillations. In previous electroencephalogram (EEG) studies, tACS has been found to modulate brain oscillatory activity in a frequency-specific manner. However, the spatial distribution and hemodynamic response for this modulation remains poorly understood. Functional magnetic resonance imaging (fMRI) has the advantage of measuring neuronal activity in regions not only below the tACS electrodes but also across the whole brain with high spatial resolution. Here, we measured fMRI signal while applying tACS to modulate rhythmic visual activity. During fMRI acquisition, tACS at different frequencies (4, 8, 16, and 32 Hz) was applied along with visual flicker stimulation at 8 and 16 Hz. We analyzed the blood-oxygen-level-dependent (BOLD) signal difference between tACS-ON vs tACS-OFF, and different frequency combinations (e.g., 4 Hz tACS, 8 Hz flicker vs 8 Hz tACS, 8 Hz flicker). We observed significant tACS modulation effects on BOLD responses when the tACS frequency matched the visual flicker frequency or the second harmonic frequency. The main effects were predominantly seen in regions that were activated by the visual task and targeted by the tACS current distribution. These findings bridge different scientific domains of tACS research and demonstrate that fMRI could localize the tACS effect on stimulus-induced brain rhythms, which could lead to a new approach for understanding the high-level cognitive process shaped by the ongoing oscillatory signal. © 2018 Wiley Periodicals, Inc.
Affective and cognitive reactions to subliminal flicker from fluorescent lighting.
Knez, Igor
2014-05-01
This study renews the classical concept of subliminal perception (Peirce & Jastrow, 1884) by investigating the impact of subliminal flicker from fluorescent lighting on affect and cognitive performance. It was predicted that low compared to high frequency lighting (latter compared to former emits non-flickering light) would evoke larger changes in affective states and also impair cognitive performance. Subjects reported high rather than low frequency lighting to be more pleasant, which, in turn, enhanced their problem solving performance. This suggests that sensory processing can take place outside of conscious awareness resulting in conscious emotional consequences; indicating a role of affect in subliminal/implicit perception, and that positive affect may facilitate cognitive task performance. Copyright © 2014 Elsevier Inc. All rights reserved.
Ruhnau, Philipp; Keitel, Christian; Lithari, Chrysa; Weisz, Nathan; Neuling, Toralf
2016-01-01
We tested a novel combination of two neuro-stimulation techniques, transcranial alternating current stimulation (tACS) and frequency tagging, that promises powerful paradigms to study the causal role of rhythmic brain activity in perception and cognition. Participants viewed a stimulus flickering at 7 or 11 Hz that elicited periodic brain activity, termed steady-state responses (SSRs), at the same temporal frequency and its higher order harmonics. Further, they received simultaneous tACS at 7 or 11 Hz that either matched or differed from the flicker frequency. Sham tACS served as a control condition. Recent advances in reconstructing cortical sources of oscillatory activity allowed us to measure SSRs during concurrent tACS, which is known to impose strong artifacts in magnetoencephalographic (MEG) recordings. For the first time, we were thus able to demonstrate immediate effects of tACS on SSR-indexed early visual processing. Our data suggest that tACS effects are largely frequency-specific and reveal a characteristic pattern of differential influences on the harmonic constituents of SSRs. PMID:27199707
Carvalho, Paulo S. M.; Noltie, Douglas B.; Tillitt, D.E.
2002-01-01
We developed a system for evaluation of visual function in larval and adult fish. Both optomotor (swimming) and optokinetic (eye movement) responses were monitored and recorded using a system of rotating stripes. The system allowed manipulation of factors such as width of the stripes used, rotation speed of the striped drum, and light illuminance levels within both the scotopic and photopic ranges. Precise control of these factors allowed quantitative measurements of visual acuity and motion detection. Using this apparatus, we tested the hypothesis that significant posthatch ontogenetic improvements in visual function occur in the medaka Oryzias latipes, and also that this species shows significant in ovo neuronal development. Significant improvements in the acuity angle alpha (ability to discriminate detail) were observed from approximately 5 degrees at hatch to 1 degree in the oldest adult stages. In addition, we measured a significant improvement in flicker fusion thresholds (motion detection skills) between larval and adult life stages within both the scotopic and photopic ranges of light illuminance. Ranges of flicker fusion thresholds (X±SD) at log I=1.96 (photopic) varied from 37.2±1.6 cycles/s in young adults to 18.6±1.6 cycles/s in young larvae 10 days posthatch. At log I=−2.54 (scotopic), flicker fusion thresholds varied from 5.8±0.7 cycles/s in young adults to 1.7±0.4 cycles/s in young larvae 10 days posthatch. Light sensitivity increased approximately 2.9 log units from early hatched larval stages to adults. The demonstrated ontogenetic improvements in visual function probably enable the fish to explore new resources, thereby enlarging their fundamental niche.
NASA Astrophysics Data System (ADS)
Arie, Takayuki; Jin, Albert; Dvorak, James
2002-03-01
Infectious processes often modulate the intrinsic properties of vertebrate cells. We studied the modulation of human erythrocyte flicker during the intra-erythrocytic cycle of Plasmodium falciparum malaria using video microscopy imaging and a data analysis system of our design to extract flicker spectra and lateral cell edge undulations of individual erythrocytes at various stages of infection. The total flicker power, the power weighted mean flicker frequency, the mode amplitudes of lateral undulations, and the time correlation of translation mode was quantified by infectious stage and modeled theoretically. Our results suggest that malaria-infected erythrocytes become increasingly more rigid following infection and provide an insight into the modulation of erythrocyte cytoplasmic viscosity by the parasites. These studies of malaria-infected erythrocytes elucidate the kinetics of both membrane and cellular changes that are relevant to blood microcirculation and improve our understanding of the malaria disease process.
A simple handheld pupillometer for chromatic Flicker studies
NASA Astrophysics Data System (ADS)
Bernabei, M.; Tinarelli, R.; Peretto, L.; Rovati, L.
2014-02-01
A portable pupillometer has been developed which is capable of performing accurate measurements of the pupil diameter during chromatic flicker stimulations. The handheld measuring system records the near-infrared image of the pupil at the rate of 25 fps and simultaneously stimulates the eye using a diffused flicker light generated by light emitting diodes (LEDs). Intensity, frequency and chromatic coordinates of the stimulus can be easily adjusted using a user-friendly graphical interface. Thanks to a chromatic monitoring of the stimulus close to the plane of the eye, photopically matched conditions can be easily achieved. The pupil diameter/area can be measured during flickering stimuli that are generated with frequency in a range of 0.1-20 Hz. The electronic unit, properly connected to the personal computer through a USB port, drives the optical unit, which can be easily held in a hand. The software interface controlling the system was developed in LabVIEW. This paper describes the instrument optical setup, front-end electronics and data processing. Moreover preliminary results obtained on a voluntary are reported.
Photovoltaic restoration of sight with high visual acuity
Lorach, Henri; Goetz, Georges; Smith, Richard; Lei, Xin; Mandel, Yossi; Kamins, Theodore; Mathieson, Keith; Huie, Philip; Harris, James; Sher, Alexander; Palanker, Daniel
2015-01-01
Patients with retinal degeneration lose sight due to gradual demise of photoreceptors. Electrical stimulation of the surviving retinal neurons provides an alternative route for delivery of visual information. We demonstrate that subretinal arrays with 70 μm photovoltaic pixels provide highly localized stimulation, with electrical and visual receptive fields of comparable sizes in rat retinal ganglion cells. Similarly to normal vision, retinal response to prosthetic stimulation exhibits flicker fusion at high frequencies, adaptation to static images and non-linear spatial summation. In rats with retinal degeneration, these photovoltaic arrays provide spatial resolution of 64 ± 11 μm, corresponding to half of the normal visual acuity in pigmented rats. Ease of implantation of these wireless and modular arrays, combined with their high resolution opens the door to functional restoration of sight. PMID:25915832
Scherbaum, Stefan; Frisch, Simon; Dshemuchadse, Maja
2016-01-01
Selective attention and its adaptation by cognitive control processes are considered a core aspect of goal-directed action. Often, selective attention is studied behaviorally with conflict tasks, but an emerging neuroscientific method for the study of selective attention is EEG frequency tagging. It applies different flicker frequencies to the stimuli of interest eliciting steady state visual evoked potentials (SSVEPs) in the EEG. These oscillating SSVEPs in the EEG allow tracing the allocation of selective attention to each tagged stimulus continuously over time. The present behavioral investigation points to an important caveat of using tagging frequencies: The flicker of stimuli not only produces a useful neuroscientific marker of selective attention, but interacts with the adaptation of selective attention itself. Our results indicate that RT patterns of adaptation after response conflict (so-called conflict adaptation) are reversed when flicker frequencies switch at once. However, this effect of frequency switches is specific to the adaptation by conflict-driven control processes, since we find no effects of frequency switches on inhibitory control processes after no-go trials. We discuss the theoretical implications of this finding and propose precautions that should be taken into account when studying conflict adaptation using frequency tagging in order to control for the described confounds. Copyright © 2015 Elsevier B.V. All rights reserved.
Noise frame duration, masking potency and whiteness of temporal noise.
Kukkonen, Heljä; Rovamo, Jyrki; Donner, Kristian; Tammikallio, Marja; Raninen, Antti
2002-09-01
Because of the limited contrast range, increasing the duration of the noise frame is often the only option for increasing the masking potency of external, white temporal noise. This, however, reduces the high-frequency cutoff beyond which noise is no longer white. This study was conducted to determine the longest noise frame duration that produces the strongest masking effect and still mimics white noise on the detection of sinusoidal flicker. Contrast energy thresholds (E(th)) were measured for flicker at 1.25 to 20 Hz in strong, purely temporal (spatially uniform), additive, external noise. The masking power of white external noise, characterized by its spectral density at zero frequency N0, increases with the duration of the noise frame. For short noise frame durations, E(th) increased in direct proportion to N0, keeping the nominal signal-to-noise ratio [SNR = (E(th)/N0)(0.5)] constant at threshold. The masking effect thus increased with the duration of the noise frame and the noise mimicked white noise. When noise frame duration and N0 increased further, the nominal SNR at threshold started to decrease, indicating that noise no longer mimicked white noise. The minimum number of noise frames per flicker cycle needed to mimic white noise decreased with increasing flicker frequency from 8.3 at 1.25 Hz to 1.6 at 20 Hz. The critical high-frequency cutoff of detection-limiting temporal noise in terms of noise frames per signal cycle depends on the temporal frequency of the signal. This is opposite to the situation in the spatial domain and must be taken into consideration when temporal signals are masked with temporal noise.
Hoffman, David M.; Karasev, Vasiliy I.; Banks, Martin S.
2011-01-01
Most stereoscopic displays rely on field-sequential presentation to present different images to the left and right eyes. With sequential presentation, images are delivered to each eye in alternation with dark intervals, and each eye receives its images in counter phase with the other eye. This type of presentation can exacerbate image artifacts including flicker, and the appearance of unsmooth motion. To address the flicker problem, some methods repeat images multiple times before updating to new ones. This greatly reduces flicker visibility, but makes motion appear less smooth. This paper describes an investigation of how different presentation methods affect the visibility of flicker, motion artifacts, and distortions in perceived depth. It begins with an examination of these methods in the spatio-temporal frequency domain. From this examination, it describes a series of predictions for how presentation rate, object speed, simultaneity of image delivery to the two eyes, and other properties ought to affect flicker, motion artifacts, and depth distortions, and reports a series of experiments that tested these predictions. The results confirmed essentially all of the predictions. The paper concludes with a summary and series of recommendations for the best approach to minimize these undesirable effects. PMID:21572544
A novel stimulation method for multi-class SSVEP-BCI using intermodulation frequencies
NASA Astrophysics Data System (ADS)
Chen, Xiaogang; Wang, Yijun; Zhang, Shangen; Gao, Shangkai; Hu, Yong; Gao, Xiaorong
2017-04-01
Objective. Steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) has been widely investigated because of its easy system configuration, high information transfer rate (ITR) and little user training. However, due to the limitations of brain responses and the refresh rate of a monitor, the available stimulation frequencies for practical BCI application are generally restricted. Approach. This study introduced a novel stimulation method using intermodulation frequencies for SSVEP-BCIs that had targets flickering at the same frequency but with different additional modulation frequencies. The additional modulation frequencies were generated on the basis of choosing desired flickering frequencies. The conventional frame-based ‘on/off’ stimulation method was used to realize the desired flickering frequencies. All visual stimulation was present on a conventional LCD screen. A 9-target SSVEP-BCI based on intermodulation frequencies was implemented for performance evaluation. To optimize the stimulation design, three approaches (C: chromatic; L: luminance; CL: chromatic and luminance) were evaluated by online testing and offline analysis. Main results. SSVEP-BCIs with different paradigms (C, L, and CL) enabled us not only to encode more targets, but also to reliably evoke intermodulation frequencies. The online accuracies for the three paradigms were 91.67% (C), 93.98% (L), and 96.41% (CL). The CL condition achieved the highest classification performance. Significance. These results demonstrated the efficacy of three approaches (C, L, and CL) for eliciting intermodulation frequencies for multi-class SSVEP-BCIs. The combination of chromatic and luminance characteristics of the visual stimuli is the most efficient way for the intermodulation frequency coding method.
Covic, Amra; Keitel, Christian; Porcu, Emanuele; Schröger, Erich; Müller, Matthias M
2017-11-01
The neural processing of a visual stimulus can be facilitated by attending to its position or by a co-occurring auditory tone. Using frequency-tagging, we investigated whether facilitation by spatial attention and audio-visual synchrony rely on similar neural processes. Participants attended to one of two flickering Gabor patches (14.17 and 17 Hz) located in opposite lower visual fields. Gabor patches further "pulsed" (i.e. showed smooth spatial frequency variations) at distinct rates (3.14 and 3.63 Hz). Frequency-modulating an auditory stimulus at the pulse-rate of one of the visual stimuli established audio-visual synchrony. Flicker and pulsed stimulation elicited stimulus-locked rhythmic electrophysiological brain responses that allowed tracking the neural processing of simultaneously presented Gabor patches. These steady-state responses (SSRs) were quantified in the spectral domain to examine visual stimulus processing under conditions of synchronous vs. asynchronous tone presentation and when respective stimulus positions were attended vs. unattended. Strikingly, unique patterns of effects on pulse- and flicker driven SSRs indicated that spatial attention and audiovisual synchrony facilitated early visual processing in parallel and via different cortical processes. We found attention effects to resemble the classical top-down gain effect facilitating both, flicker and pulse-driven SSRs. Audio-visual synchrony, in turn, only amplified synchrony-producing stimulus aspects (i.e. pulse-driven SSRs) possibly highlighting the role of temporally co-occurring sights and sounds in bottom-up multisensory integration. Copyright © 2017 Elsevier Inc. All rights reserved.
Brain-computer interface based on intermodulation frequency
NASA Astrophysics Data System (ADS)
Chen, Xiaogang; Chen, Zhikai; Gao, Shangkai; Gao, Xiaorong
2013-12-01
Objective. Most recent steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) systems have used a single frequency for each target, so that a large number of targets require a large number of stimulus frequencies and therefore a wider frequency band. However, human beings show good SSVEP responses only in a limited range of frequencies. Furthermore, this issue is especially problematic if the SSVEP-based BCI takes a PC monitor as a stimulator, which is only capable of generating a limited range of frequencies. To mitigate this issue, this study presents an innovative coding method for SSVEP-based BCI by means of intermodulation frequencies. Approach. Simultaneous modulations of stimulus luminance and color at different frequencies were utilized to induce intermodulation frequencies. Luminance flickered at relatively large frequency (10, 12, 15 Hz), while color alternated at low frequency (0.5, 1 Hz). An attractive feature of the proposed method was that it would substantially increase the number of targets at a single flickering frequency by altering color modulated frequencies. Based on this method, the BCI system presented in this study realized eight targets merely using three flickering frequencies. Main results. The online results obtained from 15 subjects (14 healthy and 1 with stroke) revealed that an average classification accuracy of 93.83% and information transfer rate (ITR) of 33.80 bit min-1 were achieved using our proposed SSVEP-based BCI system. Specifically, 5 out of the 15 subjects exhibited an ITR of 40.00 bit min-1 with a classification accuracy of 100%. Significance. These results suggested that intermodulation frequencies could be adopted as steady responses in BCI, for which our system could be used as a practical BCI system.
Polychromatic SSVEP stimuli with subtle flickering adapted to brain-display interactions
NASA Astrophysics Data System (ADS)
Chien, Yu-Yi; Lin, Fang-Cheng; Zao, John K.; Chou, Ching-Chi; Huang, Yi-Pai; Kuo, Heng-Yuan; Wang, Yijun; Jung, Tzyy-Ping; Shieh, Han-Ping D.
2017-02-01
Objective. Interactive displays armed with natural user interfaces (NUIs) will likely lead the next breakthrough in consumer electronics, and brain-computer interfaces (BCIs) are often regarded as the ultimate NUI-enabling machines to respond to human emotions and mental states. Steady-state visual evoked potentials (SSVEPs) are a commonly used BCI modality due to the ease of detection and high information transfer rates. However, the presence of flickering stimuli may cause user discomfort and can even induce migraines and seizures. With the aim of designing visual stimuli that can be embedded into video images, this study developed a novel approach to induce detectable SSVEPs using a composition of red/green/blue flickering lights. Approach. Based on the opponent theory of colour vision, this study used 32 Hz/40 Hz rectangular red-green or red-blue LED light pulses with a 50% duty cycle, balanced/equal luminance and 0°/180° phase shifts as the stimulating light sources and tested their efficacy in producing SSVEP responses with high signal-to-noise ratios (SNRs) while reducing the perceived flickering sensation. Main results. The empirical results from ten healthy subjects showed that dual-colour lights flickering at 32 Hz/40 Hz with a 50% duty cycle and 180° phase shift achieved a greater than 90% detection accuracy with little or no flickering sensation. Significance. As a first step in developing an embedded SSVEP stimulus in commercial displays, this study provides a foundation for developing a combination of three primary colour flickering backlights with adjustable luminance proportions to create a subtle flickering polychromatic light that can elicit SSVEPs at the basic flickering frequency.
Flicker Noise in GNSS Station Position Time Series: How much is due to Crustal Loading Deformations?
NASA Astrophysics Data System (ADS)
Rebischung, P.; Chanard, K.; Metivier, L.; Altamimi, Z.
2017-12-01
The presence of colored noise in GNSS station position time series was detected 20 years ago. It has been shown since then that the background spectrum of non-linear GNSS station position residuals closely follows a power-law process (known as flicker noise, 1/f noise or pink noise), with some white noise taking over at the highest frequencies. However, the origin of the flicker noise present in GNSS station position time series is still unclear. Flicker noise is often described as intrinsic to the GNSS system, i.e. due to errors in the GNSS observations or in their modeling, but no such error source has been identified so far that could explain the level of observed flicker noise, nor its spatial correlation.We investigate another possible contributor to the observed flicker noise, namely real crustal displacements driven by surface mass transports, i.e. non-tidal loading deformations. This study is motivated by the presence of power-law noise in the time series of low-degree (≤ 40) and low-order (≤ 12) Stokes coefficients observed by GRACE - power-law noise might also exist at higher degrees and orders, but obscured by GRACE observational noise. By comparing GNSS station position time series with loading deformation time series derived from GRACE gravity fields, both with their periodic components removed, we therefore assess whether GNSS and GRACE both plausibly observe the same flicker behavior of surface mass transports / loading deformations. Taking into account GRACE observability limitations, we also quantify the amount of flicker noise in GNSS station position time series that could be explained by such flicker loading deformations.
Stringham, James M.; Stringham, Nicole T.; O’Brien, Kevin J.
2017-01-01
The dramatic rise in the use of smartphones, tablets, and laptop computers over the past decade has raised concerns about potentially deleterious health effects of increased “screen time” (ST) and associated short-wavelength (blue) light exposure. We determined baseline associations and effects of 6 months’ supplementation with the macular carotenoids (MC) lutein, zeaxanthin, and mesozeaxanthin on the blue-absorbing macular pigment (MP) and measures of sleep quality, visual performance, and physical indicators of excessive ST. Forty-eight healthy young adults with at least 6 h of daily near-field ST exposure participated in this placebo-controlled trial. Visual performance measures included contrast sensitivity, critical flicker fusion, disability glare, and photostress recovery. Physical indicators of excessive screen time and sleep quality were assessed via questionnaire. MP optical density (MPOD) was assessed via heterochromatic flicker photometry. At baseline, MPOD was correlated significantly with all visual performance measures (p < 0.05 for all). MC supplementation (24 mg daily) yielded significant improvement in MPOD, overall sleep quality, headache frequency, eye strain, eye fatigue, and all visual performance measures, versus placebo (p < 0.05 for all). Increased MPOD significantly improves visual performance and, in turn, improves several undesirable physical outcomes associated with excessive ST. The improvement in sleep quality was not directly related to increases in MPOD, and may be due to systemic reduction in oxidative stress and inflammation. PMID:28661438
Stringham, James M; Stringham, Nicole T; O'Brien, Kevin J
2017-06-29
The dramatic rise in the use of smartphones, tablets, and laptop computers over the past decade has raised concerns about potentially deleterious health effects of increased "screen time" (ST) and associated short-wavelength (blue) light exposure. We determined baseline associations and effects of 6 months' supplementation with the macular carotenoids (MC) lutein, zeaxanthin, and mesozeaxanthin on the blue-absorbing macular pigment (MP) and measures of sleep quality, visual performance, and physical indicators of excessive ST. Forty-eight healthy young adults with at least 6 h of daily near-field ST exposure participated in this placebo-controlled trial. Visual performance measures included contrast sensitivity, critical flicker fusion, disability glare, and photostress recovery. Physical indicators of excessive screen time and sleep quality were assessed via questionnaire. MP optical density (MPOD) was assessed via heterochromatic flicker photometry. At baseline, MPOD was correlated significantly with all visual performance measures ( p < 0.05 for all). MC supplementation (24 mg daily) yielded significant improvement in MPOD, overall sleep quality, headache frequency, eye strain, eye fatigue, and all visual performance measures, versus placebo ( p < 0.05 for all). Increased MPOD significantly improves visual performance and, in turn, improves several undesirable physical outcomes associated with excessive ST. The improvement in sleep quality was not directly related to increases in MPOD, and may be due to systemic reduction in oxidative stress and inflammation.
The relation between the macular carotenoids, lutein and zeaxanthin, and temporal vision.
Renzi, Lisa M; Hammond, Billy R
2010-07-01
Lutein (L) and zeaxanthin (Z) are the dominant carotenoids within the central retina (there, termed macular pigment, MP) and brain (approximately 70% of total carotenoid concentration). Past studies have shown that MP is related to many static indicators of visual performance, such as visibility and disability glare. It has also been shown that MP is related to a dynamic measure of visual performance, the critical flicker fusion threshold (CFF). In this study, we examine whether MP is related to CFF in a larger sample. We also test the relation between MP and the more complete temporal contrast sensitivity function (TCSF). A total of 70 participants were assessed for a comparison of MP and the full temporal function. A separate pool of 354 participants was assessed for a MP and CFF comparison. Peak MP density was measured psychophysically (via heterochromatic flicker photometry) using a 1-degree diameter test. CFF was measured using a 1-degree 570 nm test varied at 100% modulation. The full TCSF was measured centrally using a 1-degree, 660 nm test (the modulation depth of which could be adjusted directly by the subject) centered within a 5.5-degree, 660 nm surround. A small fixation point was used to test a 7-degree parafoveal site. MP density was positively related to temporal function as assessed by the full TCSF in the center (n = 70, r = -0.29, p < 0.01) but not at the parafoveal location (p < 0.07). MP was also positively related to critical flicker fusion thresholds (n = 354, r = 0.21, p < 0.0001).
Nakanishi, Masaki; Wang, Yijun; Wang, Yu-Te; Mitsukura, Yasue; Jung, Tzyy-Ping
2014-01-01
In the study of steady-state visual evoked potentials (SSVEPs), it remains a challenge to present visual flickers at flexible frequencies using monitor refresh rate. For example, in an SSVEP-based brain-computer interface (BCI), it is difficult to present a large number of visual flickers simultaneously on a monitor. This study aims to explore whether or how a newly proposed frequency approximation approach changes signal characteristics of SSVEPs. At 10 Hz and 12 Hz, the SSVEPs elicited using two refresh rates (75 Hz and 120 Hz) were measured separately to represent the approximation and constant-period approaches. This study compared amplitude, signal-to-noise ratio (SNR), phase, latency, scalp distribution, and frequency detection accuracy of SSVEPs elicited using the two approaches. To further prove the efficacy of the approximation approach, this study implemented an eight-target BCI using frequencies from 8-15 Hz. The SSVEPs elicited by the two approaches were found comparable with regard to all parameters except amplitude and SNR of SSVEPs at 12 Hz. The BCI obtained an averaged information transfer rate (ITR) of 95.0 bits/min across 10 subjects with a maximum ITR of 120 bits/min on two subjects, the highest ITR reported in the SSVEP-based BCIs. This study clearly showed that the frequency approximation approach can elicit robust SSVEPs at flexible frequencies using monitor refresh rate and thereby can largely facilitate various SSVEP-related studies in neural engineering and visual neuroscience.
Chang, Hsiang-Chih; Lee, Po-Lei; Lo, Men-Tzung; Lee, I-Hui; Yeh, Ting-Kuang; Chang, Chun-Yen
2012-05-01
This study proposes a steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) independent of amplitude-frequency and phase calibrations. Six stepping delay flickering sequences (SDFSs) at 32-Hz flickering frequency were used to implement a six-command BCI system. EEG signals recorded from Oz position were first filtered within 29-35 Hz, segmented based on trigger events of SDFSs to obtain SDFS epochs, and then stored separately in epoch registers. An epoch-average process suppressed the inter-SDFS interference. For each detection point, the latest six SDFS epochs in each epoch register were averaged and the normalized power of averaged responses was calculated. The visual target that induced the maximum normalized power was identified as the visual target. Eight subjects were recruited in this study. All subjects were requested to produce the "563241" command sequence four times. The averaged accuracy, command transfer interval, and information transfer rate (mean ± std.) values for all eight subjects were 97.38 ± 5.97%, 3.56 ± 0.68 s, and 42.46 ± 11.17 bits/min, respectively. The proposed system requires no calibration in either the amplitude-frequency characteristic or the reference phase of SSVEP which may provide an efficient and reliable channel for the neuromuscular disabled to communicate with external environments.
Nitric oxide regulates retinal vascular tone in humans.
Dorner, Guido T; Garhofer, Gerhard; Kiss, Barbara; Polska, Elzbieta; Polak, Kaija; Riva, Charles E; Schmetterer, Leopold
2003-08-01
The purpose of the present study was to investigate the contribution of basal nitric oxide (NO) on retinal vascular tone in humans. In addition, we set out to elucidate the role of NO in flicker-induced retinal vasodilation in humans. Twelve healthy young subjects were studied in a three-way crossover design. Subjects received an intravenous infusion of either placebo or NG-monomethyl-L-arginine (L-NMMA; 3 or 6 mg/kg over 5 min), an inhibitor of NO synthase. Thereafter, diffuse luminance flicker was consecutively performed for 16, 32, and 64 s at a frequency of 8 Hz. The effect of L-NMMA on retinal arterial and venous diameter was assessed under resting conditions and during the hyperemic flicker response. Retinal vessel diameter was measured with a Zeiss retinal vessel analyzer. L-NMMA significantly reduced arterial diameter (3 mg/kg: -2%; 6 mg/kg: -4%, P < 0.001) and venous diameter (3 mg/kg: -5%; 6 mg/kg: -8%, P < 0.001). After placebo infusion, flicker induced a significant increase in retinal vessel diameter (P < 0.001). At a flicker duration of 64 s, arterial diameter increased by 4% and venous diameter increased by 3%. L-NMMA did not abolish these hyperemic responses but blunted venous vasodilation (P = 0.017) and arterial vasodilation (P = 0.02) in response to flicker stimulation. Our data indicate that NO contributes to basal retinal vascular tone in humans. In addition, NO appears to play a role in flicker-induced vasodilation of the human retinal vasculature.
Temporally flickering nanoparticles for compound cellular imaging and super resolution
NASA Astrophysics Data System (ADS)
Ilovitsh, Tali; Danan, Yossef; Meir, Rinat; Meiri, Amihai; Zalevsky, Zeev
2016-03-01
This work presents the use of flickering nanoparticles for imaging biological samples. The method has high noise immunity, and it enables the detection of overlapping types of GNPs, at significantly sub-diffraction distances, making it attractive for super resolving localization microscopy techniques. The method utilizes a lock-in technique at which the imaging of the sample is done using a time-modulated laser beam that match the number of the types of gold nanoparticles (GNPs) that label a given sample, and resulting in the excitation of the temporal flickering of the scattered light at known temporal frequencies. The final image where the GNPs are spatially separated is obtained using post processing where the proper spectral components corresponding to the different modulation frequencies are extracted. This allows the simultaneous super resolved imaging of multiple types of GNPs that label targets of interest within biological samples. Additionally applying the post-processing algorithm of the K-factor image decomposition algorithm can further improve the performance of the proposed approach.
Low-frequency flicker noise in a MSM device made with single Si nanowire (diameter ≈ 50 nm).
Samanta, Sudeshna; Das, Kaustuv; Raychaudhuri, Arup Kumar
2013-04-10
: Low-frequency flicker noise has been measured in a metal-semiconductor-metal (MSM) device made from a single strand of a single crystalline Si nanowire (diameter approximately 50 nm). Measurement was done with an alternating current (ac) excitation for the noise measurement superimposed with direct current (dc) bias that can be controlled independently. The observed noise has a spectral power density ∝1/fα. Application of the superimposed dc bias (retaining the ac bias unchanged) with a value more than the Schottky barrier height at the junction leads to a large suppression of the noise amplitude along with a change of α from 2 to ≈ 1. The dc bias-dependent part of the noise has been interpreted as arising from the interface region. The residual dc bias-independent flicker noise is suggested to arise from the single strand of Si nanowire, which has the conventional 1/f spectral power density.
Low-frequency flicker noise in a MSM device made with single Si nanowire (diameter ≈ 50 nm)
2013-01-01
Low-frequency flicker noise has been measured in a metal-semiconductor-metal (MSM) device made from a single strand of a single crystalline Si nanowire (diameter approximately 50 nm). Measurement was done with an alternating current (ac) excitation for the noise measurement superimposed with direct current (dc) bias that can be controlled independently. The observed noise has a spectral power density ∝1/fα. Application of the superimposed dc bias (retaining the ac bias unchanged) with a value more than the Schottky barrier height at the junction leads to a large suppression of the noise amplitude along with a change of α from 2 to ≈ 1. The dc bias-dependent part of the noise has been interpreted as arising from the interface region. The residual dc bias-independent flicker noise is suggested to arise from the single strand of Si nanowire, which has the conventional 1/f spectral power density. PMID:23574820
Harding, Graham; Harding, Pamela; Wilkins, Arnold
2008-06-01
Wind turbines are known to produce shadow flicker by interruption of sunlight by the turbine blades. Known parameters of the seizure provoking effect of flicker, i.e., contrast, frequency, mark-space ratio, retinal area stimulated and percentage of visual cortex involved were applied to wind turbine features. The proportion of patients affected by viewing wind turbines expressed as distance in multiples of the hub height of the turbine showed that seizure risk does not decrease significantly until the distance exceeds 100 times the hub height. Since risk does not diminish with viewing distance, flash frequency is therefore the critical factor and should be kept to a maximum of three per second, i.e., sixty revolutions per minute for a three-bladed turbine. On wind farms the shadows cast by one turbine on another should not be viewable by the public if the cumulative flash rate exceeds three per second. Turbine blades should not be reflective.
Van De Poll, Matthew N; Zajaczkowski, Esmi L; Taylor, Gavin J; Srinivasan, Mandyam V; van Swinderen, Bruno
2015-11-01
Closed-loop paradigms provide an effective approach for studying visual choice behaviour and attention in small animals. Different flying and walking paradigms have been developed to investigate behavioural and neuronal responses to competing stimuli in insects such as bees and flies. However, the variety of stimulus choices that can be presented over one experiment is often limited. Current choice paradigms are mostly constrained as single binary choice scenarios that are influenced by the linear structure of classical conditioning paradigms. Here, we present a novel behavioural choice paradigm that allows animals to explore a closed geometry of interconnected binary choices by repeatedly selecting among competing objects, thereby revealing stimulus preferences in an historical context. We used our novel paradigm to investigate visual flicker preferences in honeybees (Apis mellifera) and found significant preferences for 20-25 Hz flicker and avoidance of higher (50-100 Hz) and lower (2-4 Hz) flicker frequencies. Similar results were found when bees were presented with three simultaneous choices instead of two, and when they were given the chance to select previously rejected choices. Our results show that honeybees can discriminate among different flicker frequencies and that their visual preferences are persistent even under different experimental conditions. Interestingly, avoided stimuli were more attractive if they were novel, suggesting that novelty salience can override innate preferences. Our recursive virtual reality environment provides a new approach to studying visual discrimination and choice behaviour in animals. © 2015. Published by The Company of Biologists Ltd.
Assessment of the Absolute Excitatory Level of the Retina by Flicker ERG.
Tanimoto, Naoyuki; Seeliger, Mathias W
2018-01-01
Electroretinography (ERG) is important for functional diagnostics of the retina. Types of information about retinal function obtainable by ERG differ depending on recording conditions, e.g., a combination of light stimulus and adaptation. In terms of stimulation, single-flash and flicker stimuli are frequently used because response properties have been well investigated, allowing an assessment of fundamental retinal functionality; for example, how photoreceptors and bipolar cells, including signal transmission between them, are affected under pathological conditions. Usually, ERGs are recorded with a nonzero lower cutoff frequency of amplifiers to avoid certain artifacts, and additionally, responses are averaged over time so that non-event-related signals are cancelled out. However, the improved signal quality is associated with a loss of information. Especially in steady-state flicker ERG, information about the absolute baseline of recordings is missing because the prestimulus baseline is not included on the recording trace as well as because a zero response is obtained in all cases in which the signal baseline stays constant for a sufficient amount of time. In other words, it is impossible to tell from the conventional flicker ERG whether a zero signal is obtained under conditions of maximal or no excitation of the visual system. In this chapter, we describe a direct current ERG protocol (featuring a lower cutoff frequency of zero) with repetitive single flashes mimicking conventional flicker that contains a defined onset. Using this recording protocol, it is possible to assess not only the absolute excitatory level of the retina but also the development of steady-state responses from the single flash response.
Effect of Cellular Mobile Phone Use and Cetrizine on Hand-Eye Coordination and Visual Acuity.
Gawit, Kalpita Ganpat; Tiwari, Smita Anand; Kasabe, Gauri Hari; Deshpande, Pradeep Kisanrao; Ghongane, Balasaheb Baburao
2017-09-01
Cellular mobile phones are a major cause of distraction especially while driving. The aggressive and inappropriate use of cellular mobile phones has increased the risk of accidents. Similar alerts are available in literature for certain substances and drugs (e.g. second generation anti H1 drug -Cetirizine) which also derange psychomotor performance and parameters of alertness. This study measured variations in hand-eye coordination and visual acuity due to use of cellular mobile phone in comparison to that of commonly used antihistaminic drug viz., single dose Cetirizine 10 mg. It was a single blind, single dose, interventional study, 100 healthy human volunteers divided into two groups. Baseline readings of all volunteers were noted. Group-I (n=50) was Cetirizine group (10mg orally stat), Group -II (n=50) Cellular mobile phone user group. Alertness was tested on hand- steadiness tester (Reaction Time Index = RTI) and on Flicker-fusion apparatus (visual acuity - Critical Flicker Fusion Frequency per second= CFFF/sec). Baseline readings of all volunteers were noted before intervention. Baseline was compared with readings at three hour post-intervention and was analysed by paired t-test. Inter-group comparison of parameters was also done and was analysed by unpaired t-test. The baseline RTI (95.46±41.74, 85.11±39.05) and CFF low and high (40.07±9.970, 40.76±9.309 and 40.42±9.035, 40.48±9.863) respectively, in Cetirizine group and Mobile user group were comparable. The RTI increased significantly (116.4±51.46, 102.8±49.26) in both the groups after intervention. However, there is no significant change in CFF intensity from baseline in either group post-intervention. Concurrent use of mobile phone while performing tasks, showed significant impairment of hand-steadiness which was comparable to that produced by single dose Cetirizine 10 mg and this may be one of the factors contributing to their close association with road traffic accidents.
Power system frequency estimation based on an orthogonal decomposition method
NASA Astrophysics Data System (ADS)
Lee, Chih-Hung; Tsai, Men-Shen
2018-06-01
In recent years, several frequency estimation techniques have been proposed by which to estimate the frequency variations in power systems. In order to properly identify power quality issues under asynchronously-sampled signals that are contaminated with noise, flicker, and harmonic and inter-harmonic components, a good frequency estimator that is able to estimate the frequency as well as the rate of frequency changes precisely is needed. However, accurately estimating the fundamental frequency becomes a very difficult task without a priori information about the sampling frequency. In this paper, a better frequency evaluation scheme for power systems is proposed. This method employs a reconstruction technique in combination with orthogonal filters, which may maintain the required frequency characteristics of the orthogonal filters and improve the overall efficiency of power system monitoring through two-stage sliding discrete Fourier transforms. The results showed that this method can accurately estimate the power system frequency under different conditions, including asynchronously sampled signals contaminated by noise, flicker, and harmonic and inter-harmonic components. The proposed approach also provides high computational efficiency.
Sauvé, Y; Pinilla, I; Lund, R D
2006-04-01
We quantified rod- and cone-related electroretinogram (ERG) responses following subretinal injections of the human-derived retinal pigment epithelial (hRPE) cell line ARPE-19 at age P23 to prevent progressive photoreceptor loss in the Royal College of Surgeons (RCS) rat. Culture medium-injected eyes served as sham controls. At P60, in comparison with sham-injected eyes, all recordings from hRPE-injected eyes showed preserved scotopic a- and b-waves, oscillatory potentials, double-flash-derived rod b-waves and photopic cone b-waves, and flicker critical fusion frequencies and amplitudes. Although the actual preservation did not exceed 10% of a-wave and 20% of b-wave amplitude values in non-dystrophic RCS and deteriorated rapidly by P90, rod- and cone-related ERG parameters were still recordable up to P120 unlike the virtually unresponsive sham-injected eyes.
78 FR 58487 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-24
... display units (DUs). These DUs exhibited susceptibility to radio frequency emissions in WiFi frequency... certification of WiFi system installations. The phase 3 DUs provide primary flight information including... flickering and blanking when subjected to radio frequency emissions in WiFi frequency bands at radiated power...
NASA Technical Reports Server (NTRS)
Wu, Andy
1995-01-01
Allan Deviation computations of linear frequency synthesizer systems have been reported previously using real-time simulations. Even though it takes less time compared with the actual measurement, it is still very time consuming to compute the Allan Deviation for long sample times with the desired confidence level. Also noises, such as flicker phase noise and flicker frequency noise, can not be simulated precisely. The use of frequency domain techniques can overcome these drawbacks. In this paper the system error model of a fictitious linear frequency synthesizer is developed and its performance using a Cesium (Cs) atomic frequency standard (AFS) as a reference is evaluated using frequency domain techniques. For a linear timing system, the power spectral density at the system output can be computed with known system transfer functions and known power spectral densities from the input noise sources. The resulting power spectral density can then be used to compute the Allan Variance at the system output. Sensitivities of the Allan Variance at the system output to each of its independent input noises are obtained, and they are valuable for design trade-off and trouble-shooting.
Magnetometry with Ensembles of Nitrogen Vacancy Centers in Bulk Diamond
2015-10-23
the ESR curve. Any frequency components of the photodetector signal which are not close to the reference frequency, are filtered out. This mitigates ...indicating that we have not yet run up against thermal or flicker noise for these time scales. 5.3 Details of frequency modulation circuit In order
2015-10-14
especially because cuttlefish are colorblind. Another possible concern is the flicker frequency of the plasma screens. The plasma screens used in... flicker . Given these reasons, we believe that the most reliable behavior with the least amount of human disturbance resulted from our use of the...0138690 October 14, 2015 15 / 18 Image analysis To mitigate the likelihood of autocorrelation, we used the two usable (i.e., non-blurry) images that were
Fan, C C; Chiu, Y C; Liu, C; Lai, W W; Cheng, C H; Lin, D L; Li, G R; Lo, Y H; Chang, C W; Tsai, C C; Chang, C Y
2018-06-01
The flicker noise of source follower transistors is the dominant noise source in image sensors. This paper reports a systematic study of the shallow trench isolation effect in transistors with different sizes under high temperature conditions that correspond to the quantity of empty defect sites. The effects of shallow trench isolation sidewall defects on flicker noise characteristics are investigated. In addition, the low-frequency noise and subthreshold swing degrade simultaneously in accordance to the device gate width scaling. Both serious subthreshold leakage and considerable noise can be attributed to the high trap density near the STI edge. Consequently, we propose a coincidental relationship between the noise level and the subthreshold characteristic; its trend is identical to the experiments and simulation results.
1994-07-01
psychological refractory period 15. Two-flash threshold 16. Critical flicker fusion (CFF) 17. Steady state visually evoked response 18. Auditory brain stem...States of awareness I: Subliminal erceoption relationships to situational awareness (AL-TR-1992-0085). Brooks Air Force BaSe, TX: Armstrong...the signals required different inputs (e.g., visual versus auditory ) (Colley & Beech, 1989). Despite support of this theory from such experiments
Utilizing Retinotopic Mapping for a Multi-Target SSVEP BCI With a Single Flicker Frequency.
Maye, Alexander; Zhang, Dan; Engel, Andreas K
2017-07-01
In brain-computer interfaces (BCIs) that use the steady-state visual evoked response (SSVEP), the user selects a control command by directing attention overtly or covertly to one out of several flicker stimuli. The different control channels are encoded in the frequency, phase, or time domain of the flicker signals. Here, we present a new type of SSVEP BCI, which uses only a single flicker stimulus and yet affords controlling multiple channels. The approach rests on the observation that the relative position between the stimulus and the foci of overt attention result in distinct topographies of the SSVEP response on the scalp. By classifying these topographies, the computer can determine at which position the user is gazing. Offline data analysis in a study on 12 healthy volunteers revealed that 9 targets can be recognized with about 95±3% accuracy, corresponding to an information transfer rate (ITR) of 40.8 ± 3.3 b/min on average. We explored how the classification accuracy is affected by the number of control channels, the trial length, and the number of EEG channels. Our findings suggest that the EEG data from five channels over parieto-occipital brain areas are sufficient for reliably classifying the topographies and that there is a large potential to improve the ITR by optimizing the trial length. The robust performance and the simple stimulation setup suggest that this approach is a prime candidate for applications on desktop and tablet computers.
Feature-selective attention enhances color signals in early visual areas of the human brain.
Müller, M M; Andersen, S; Trujillo, N J; Valdés-Sosa, P; Malinowski, P; Hillyard, S A
2006-09-19
We used an electrophysiological measure of selective stimulus processing (the steady-state visual evoked potential, SSVEP) to investigate feature-specific attention to color cues. Subjects viewed a display consisting of spatially intermingled red and blue dots that continually shifted their positions at random. The red and blue dots flickered at different frequencies and thereby elicited distinguishable SSVEP signals in the visual cortex. Paying attention selectively to either the red or blue dot population produced an enhanced amplitude of its frequency-tagged SSVEP, which was localized by source modeling to early levels of the visual cortex. A control experiment showed that this selection was based on color rather than flicker frequency cues. This signal amplification of attended color items provides an empirical basis for the rapid identification of feature conjunctions during visual search, as proposed by "guided search" models.
Reducing flicker noise in chemical vapor deposition graphene field-effect transistors
NASA Astrophysics Data System (ADS)
Arnold, Heather N.; Sangwan, Vinod K.; Schmucker, Scott W.; Cress, Cory D.; Luck, Kyle A.; Friedman, Adam L.; Robinson, Jeremy T.; Marks, Tobin J.; Hersam, Mark C.
2016-02-01
Single-layer graphene derived from chemical vapor deposition (CVD) holds promise for scalable radio frequency (RF) electronic applications. However, prevalent low-frequency flicker noise (1/f noise) in CVD graphene field-effect transistors is often up-converted to higher frequencies, thus limiting RF device performance. Here, we achieve an order of magnitude reduction in 1/f noise in field-effect transistors based on CVD graphene transferred onto silicon oxide substrates by utilizing a processing protocol that avoids aqueous chemistry after graphene transfer. Correspondingly, the normalized noise spectral density (10-7-10-8 μm2 Hz-1) and noise amplitude (4 × 10-8-10-7) in these devices are comparable to those of exfoliated and suspended graphene. We attribute the reduction in 1/f noise to a decrease in the contribution of fluctuations in the scattering cross-sections of carriers arising from dynamic redistribution of interfacial disorder.
Hu, Wei-Chieh; Sari, Shanti Kartika; Hou, Shuhn-Shyurng; Lin, Ta-Hui
2016-01-01
In this study, methane–ethylene jet diffusion flames modulated by acoustic excitation in an atmospheric environment were used to investigate the effects of acoustic excitation frequency and mixed fuel on nanomaterial formation. Acoustic output power was maintained at a constant value of 10 W, while the acoustic excitation frequency was varied (f = 0–90 Hz). The results show that the flame could not be stabilized on the port when the ethylene volume concentration (ΩE) was less than 40% at f = 10 Hz, or when ΩE = 0% (i.e., pure methane) at f = 90 Hz. The reason for this is that the flame had a low intensity and was extinguished by the entrained air due to acoustic modulation. Without acoustic excitation (f = 0 Hz), the flame was comprised of a single-layer structure for all values of ΩE, and almost no carbon nanomaterials were synthesized. However, with acoustic excitation, a double-layer flame structure was generated for frequencies close to both the natural flickering frequency and the acoustically resonant frequency. This double-layer flame structure provided a favorable flame environment for the fabrication of carbon nanomaterials. Consequently, the synthesis of carbon nano-onions was significantly enhanced by acoustic excitation near both the natural flickering frequency and the acoustically resonant frequency. At f = 20 Hz (near the natural flickering frequency) for 0% ≤ ΩE ≤ 100%, a quantity of carbon nano-onions (CNOs) piled like bunches of grapes was obtained as a result of improved mixing of the fuel with ambient air. High-density CNOs were also produced at f = 70 Hz (close to the acoustically resonant frequency) for 40% ≤ ΩE ≤ 100%. Furthermore, carbon nanotubes (CNTs) were synthesized only at 80 Hz for ΩE = 0%. The suitable temperature range for the synthesis of CNTs was slightly higher than that for the formation of CNOs (about 600 °C for CNTs; 510–600 °C for CNOs). PMID:28774059
Enhanced Synthesis of Carbon Nanomaterials Using Acoustically Excited Methane Diffusion Flames
Hou, Shuhn-Shyurng; Chen, Kuan-Ming; Yang, Zong-Yun; Lin, Ta-Hui
2015-01-01
Acoustically modulated methane jet diffusion flames were used to enhance carbon nanostructure synthesis. A catalytic nickel substrate was employed to collect the deposit materials at sampling position z = 10 mm above the burner exit. The fabrication of carbon nano-onions (CNOs) and carbon nanotubes (CNTs) was significantly enhanced by acoustic excitation at frequencies near the natural flickering frequency (ƒ = 20 Hz) and near the acoustically resonant frequency (ƒ = 90 Hz), respectively. At these characteristic frequencies, flow mixing was markedly enhanced by acoustic excitation, and a flame structure with a bright slender core flame was generated, which provided a favorable flame environment for the growth of carbon nanomaterials. The production rate of CNOs was high at 20 Hz (near the natural flickering frequency), at which the gas temperature was about 680 °C. Additionally, a quantity of CNTs was obtained at 70–95 Hz, near the acoustically resonant frequency, at which the gas temperature was between 665 and 830 °C. However, no carbon nanomaterials were synthesized at other frequencies. The enhanced synthesis of CNOs and CNTs is attributed to the strong mixing of the fuel and oxidizer due to the acoustic excitation at resonant frequencies. PMID:28793473
Meyer-Rochow, V B
2001-12-01
Compound eyes, nauplius eyes, frontal organs, intracerebral ocelli, and caudal photoreceptors are the main light and darkness detectors in crustaceans, but they need not be present all at once in an individual and in some crustaceans no photoreceptors whatsoever are known. Compound eye designs reflect on their functions and have evolved to allow the eye to operate optimally under a variety of environmental conditions. Dark-light-adaptational changes manifest themselves in pigment granule translocations, cell movements, and optical adjustments which fine-tune an eye's performance to rapid and unpredictable fluctuations in ambient light intensities as well as to the slower and predictable light level changes associated with day and night oscillations. Recycling of photoreceptive membrane and light-induced membrane collapse are superficially similar events that involve the transduction cascade, intracellular calcium, and membrane fatty acid composition, but which differ in aetiology and longterm consequence. Responses to intermittant illumination and linearly polarized light evoke in the eye of many crustaceans characteristic responses that appear to be attuned to each species' special needs. How the visual responses are processed more centrally and to what extent a crustacean makes behavioural use of e-vector discrimination and flickering lights are questions, however, that still have not been satisfactorily answered for the vast majority of all crustacean species. The degree of light-induced photoreceptor damage depends on a large number of variables, but once manifest, it tends to be progressive and irreversible. Concomittant temperature stress aggravates the situation and there is evidence that free radicals and lipid hydroperoxides are involved.
Yung, Marcus; Wells, Richard P
2017-07-01
Many contemporary occupations are characterised by long periods of low loads. These lower force levels, which are relevant to the development of work-related musculoskeletal disorders, are usually not the focus of fatigue studies. In studies that did measure fatigue in light manual or precision work, within and between measurement responses were inconsistent. The aim of this study was to identify fatigue measures that were responsive at lower force levels (<10% MVC) over the course of an 8-h period. A complementary set of fatigue measures, reflecting both neuromuscular and cognitive mechanisms, was measured during a light precision micro-pipetting task performed by 11 participants. Nine measures were found to be significantly responsive over the 8-h period, including: ratings of perceived fatigue, postural tremor, blink frequency and critical flicker fusion frequency threshold. Common field measures, specifically electromyography RMS amplitude and maximum voluntary contractions, did not lead to extraordinary time effects. Practitioner summary: The findings provide insight towards the responsiveness of a complementary set of field usable fatigue measures at low work intensities Although commonly used measures did not reveal significant increases in fatigue, nine alternative measures were significantly responsive over the 8-h period.
Shioiri, Satoshi; Matsumiya, Kazumichi
2009-05-29
We investigated spatiotemporal characteristics of motion mechanisms using a new type of motion aftereffect (MAE) we found. Our stimulus comprised two superimposed sinusoidal gratings with different spatial frequencies. After exposure to the moving stimulus, observers perceived the MAE in the static test in the direction opposite to that of the high spatial frequency grating even when low spatial frequency motion was perceived during adaptation. In contrast, in the flicker test, the MAE was perceived in the direction opposite to that of the low spatial frequency grating. These MAEs indicate that two different motion systems contribute to motion perception and can be isolated by using different test stimuli. Using a psychophysical technique based on the MAE, we investigated the differences between the two motion mechanisms. The results showed that the static MAE is the aftereffect of the motion system with a high spatial and low temporal frequency tuning (slow motion detector) and the flicker MAE is the aftereffect of the motion system with a low spatial and high temporal frequency tuning (fast motion detector). We also revealed that the two motion detectors differ in orientation tuning, temporal frequency tuning, and sensitivity to relative motion.
[Comparative analysis of light sensitivity, depth and motion perception in animals and humans].
Schaeffel, F
2017-11-01
This study examined how humans perform regarding light sensitivity, depth perception and motion vision in comparison to various animals. The parameters that limit the performance of the visual system for these different functions were examined. This study was based on literature studies (search in PubMed) and own results. Light sensitivity is limited by the brightness of the retinal image, which in turn is determined by the f‑number of the eye. Furthermore, it is limited by photon noise, thermal decay of rhodopsin, noise in the phototransduction cascade and neuronal processing. In invertebrates, impressive optical tricks have been developed to increase the number of photons reaching the photoreceptors. Furthermore, the spontaneous decay of the photopigment is lower in invertebrates at the cost of higher energy consumption. For depth perception at close range, stereopsis is the most precise but is available only to a few vertebrates. In contrast, motion parallax is used by many species including vertebrates as well as invertebrates. In a few cases accommodation is used for depth measurements or chromatic aberration. In motion vision the temporal resolution of the eye is most important. The ficker fusion frequency correlates in vertebrates with metabolic turnover and body temperature but also has very high values in insects. Apart from that the flicker fusion frequency generally declines with increasing body weight. Compared to animals the performance of the visual system in humans is among the best regarding light sensitivity, is the best regarding depth resolution and in the middle range regarding motion resolution.
A Kalman Filter Clock Algorithm for Use in the Presence of Flicker Frequency Modulation Noise
2004-09-01
40, S335-S341. [5] P. M. Harris, J. A. Davis, M. G. Cox, and S. L. Shemar, 2003, “ Least - squares analysis of time series data and its application to two - way satellite time and frequency transfer measurements ,” Metrologia
NASA Technical Reports Server (NTRS)
Hellwig, H.; Stein, S. R.; Walls, F. L.; Kahan, A.
1978-01-01
The relationship between system performance and clock or oscillator performance is discussed. Tradeoffs discussed include: short term stability versus bandwidth requirements; frequency accuracy versus signal acquisition time; flicker of frequency and drift versus resynchronization time; frequency precision versus communications traffic volume; spectral purity versus bit error rate, and frequency standard stability versus frequency selection and adjustability. The benefits and tradeoffs of using precise frequency and time signals are various levels of precision and accuracy are emphasized.
Global Enhancement but Local Suppression in Feature-based Attention.
Forschack, Norman; Andersen, Søren K; Müller, Matthias M
2017-04-01
A key property of feature-based attention is global facilitation of the attended feature throughout the visual field. Previously, we presented superimposed red and blue randomly moving dot kinematograms (RDKs) flickering at a different frequency each to elicit frequency-specific steady-state visual evoked potentials (SSVEPs) that allowed us to analyze neural dynamics in early visual cortex when participants shifted attention to one of the two colors. Results showed amplification of the attended and suppression of the unattended color as measured by SSVEP amplitudes. Here, we tested whether the suppression of the unattended color also operates globally. To this end, we presented superimposed flickering red and blue RDKs in the center of a screen and a red and blue RDK in the left and right periphery, respectively, also flickering at different frequencies. Participants shifted attention to one color of the superimposed RDKs in the center to discriminate coherent motion events in the attended from the unattended color RDK, whereas the peripheral RDKs were task irrelevant. SSVEP amplitudes elicited by the centrally presented RDKs confirmed the previous findings of amplification and suppression. For peripherally located RDKs, we found the expected SSVEP amplitude increase, relative to precue baseline when color matched the one of the centrally attended RDK. We found no reduction in SSVEP amplitude relative to precue baseline, when the peripheral color matched the unattended one of the central RDK, indicating that, while facilitation in feature-based attention operates globally, suppression seems to be linked to the location of focused attention.
Face-Evoked Steady-State Visual Potentials: Effects of Presentation Rate and Face Inversion
Gruss, L. Forest; Wieser, Matthias J.; Schweinberger, Stefan R.; Keil, Andreas
2012-01-01
Face processing can be explored using electrophysiological methods. Research with event-related potentials has demonstrated the so-called face inversion effect, in which the N170 component is enhanced in amplitude and latency to inverted, compared to upright, faces. The present study explored the extent to which repetitive lower-level visual cortical engagement, reflected in flicker steady-state visual evoked potentials (ssVEPs), shows similar amplitude enhancement to face inversion. We also asked if inversion-related ssVEP modulation would be dependent on the stimulation rate at which upright and inverted faces were flickered. To this end, multiple tagging frequencies were used (5, 10, 15, and 20 Hz) across two studies (n = 21, n = 18). Results showed that amplitude enhancement of the ssVEP for inverted faces was found solely at higher stimulation frequencies (15 and 20 Hz). By contrast, lower frequency ssVEPs did not show this inversion effect. These findings suggest that stimulation frequency affects the sensitivity of ssVEPs to face inversion. PMID:23205009
Hindi Attar, Catherine; Müller, Matthias M
2012-01-01
A number of studies have shown that emotionally arousing stimuli are preferentially processed in the human brain. Whether or not this preference persists under increased perceptual load associated with a task at hand remains an open question. Here we manipulated two possible determinants of the attentional selection process, perceptual load associated with a foreground task and the emotional valence of concurrently presented task-irrelevant distractors. As a direct measure of sustained attentional resource allocation in early visual cortex we used steady-state visual evoked potentials (SSVEPs) elicited by distinct flicker frequencies of task and distractor stimuli. Subjects either performed a detection (low load) or discrimination (high load) task at a centrally presented symbol stream that flickered at 8.6 Hz while task-irrelevant neutral or unpleasant pictures from the International Affective Picture System (IAPS) flickered at a frequency of 12 Hz in the background of the stream. As reflected in target detection rates and SSVEP amplitudes to both task and distractor stimuli, unpleasant relative to neutral background pictures more strongly withdrew processing resources from the foreground task. Importantly, this finding was unaffected by the factor 'load' which turned out to be a weak modulator of attentional processing in human visual cortex.
Flicker sensitivity as a function of target area with and without temporal noise.
Rovamo, J; Donner, K; Näsänen, R; Raninen, A
2000-01-01
Flicker sensitivities (1-30 Hz) in foveal, photopic vision were measured as functions of stimulus area with and without strong external white temporal noise. Stimuli were circular, sinusoidally flickering sharp-edged spots of variable diameters (0.25-4 degrees ) but constant duration (2 s), surrounded by a uniform equiluminant field. The data was described with a model comprising (i) low-pass filtering in the retina (R), with a modulation transfer function (MTF) of a form derived from responses of cones; (ii) normalisation of the temporal luminance distribution by the average luminance; (iii) high-pass filtering by postreceptoral neural pathways (P), with an MTF proportional to temporal frequency; (iv) addition of internal white neural noise (N(i)); (v) integration over a spatial window; and (vi) detection by a suboptimal temporal matched filter of efficiency eta. In strong external noise, flicker sensitivity was independent of spot area. Without external noise, sensitivity increased with the square root of stimulus area (Piper's law) up to a critical area (A(c)), where it reaches a maximum level (S(max)). Both A(c) and eta were monotonic functions of temporal frequency (f), such that log A(c) increased and log eta decreased linearly with log f. Remarkably, the increase in spatial integration area and the decrease in efficiency were just balanced, so A(c)(f)eta(f) was invariant against f. Thus the bandpass characteristics of S(max)(f) directly reflected the composite effect of the distal filters R(f) and P(f). The temporal equivalent (N(it)) of internal neural noise (N(i)) decreased in inverse proportion to spot area up to A(c) and then stayed constant indicating that spatially homogeneous signals and noise are integrated over the same area.
NASA Astrophysics Data System (ADS)
Kim, Ji-Hoon; Jeon, Su-Jin; Ji, Myung-Gi; Park, Jun-Hee; Choi, Young-Wan
2017-02-01
Lock-in amplifier (LIA) has been widely used in optical signal detection systems because it can measure small signal under high noise level. Generally, The LIA used in optical signal detection system is composed of transimpedance amplifier (TIA), phase sensitive detector (PSD) and low pass filter (LPF). But commercial LIA using LPF is affected by flicker noise. To avoid flicker noise, there is 2ω detection LIA using BPF. To improve the dynamic reserve (DR) of the 2ω LIA, the signal to noise ratio (SNR) of the TIA should be improved. According to the analysis of frequency response of the TIA, the noise gain can be minimized by proper choices of input capacitor (Ci) and feed-back network in the TIA in a specific frequency range. In this work, we have studied how the SNR of the TIA can be improved by a proper choice of frequency range. We have analyzed the way to control this frequency range through the change of passive component in the TIA. The result shows that the variance of the passive component in the TIA can change the specific frequency range where the noise gain is minimized in the uniform gain region of the TIA.
Dilation of fusion pores by crowding of SNARE proteins
Wu, Zhenyong; Bello, Oscar D; Thiyagarajan, Sathish; Auclair, Sarah Marie; Vennekate, Wensi; Krishnakumar, Shyam S; O'Shaughnessy, Ben; Karatekin, Erdem
2017-01-01
Hormones and neurotransmitters are released through fluctuating exocytotic fusion pores that can flicker open and shut multiple times. Cargo release and vesicle recycling depend on the fate of the pore, which may reseal or dilate irreversibly. Pore nucleation requires zippering between vesicle-associated v-SNAREs and target membrane t-SNAREs, but the mechanisms governing the subsequent pore dilation are not understood. Here, we probed the dilation of single fusion pores using v-SNARE-reconstituted ~23-nm-diameter discoidal nanolipoprotein particles (vNLPs) as fusion partners with cells ectopically expressing cognate, 'flipped' t-SNAREs. Pore nucleation required a minimum of two v-SNAREs per NLP face, and further increases in v-SNARE copy numbers did not affect nucleation rate. By contrast, the probability of pore dilation increased with increasing v-SNARE copies and was far from saturating at 15 v-SNARE copies per face, the NLP capacity. Our experimental and computational results suggest that SNARE availability may be pivotal in determining whether neurotransmitters or hormones are released through a transient ('kiss and run') or an irreversibly dilating pore (full fusion). DOI: http://dx.doi.org/10.7554/eLife.22964.001 PMID:28346138
Accuracy metrics for judging time scale algorithms
NASA Technical Reports Server (NTRS)
Douglas, R. J.; Boulanger, J.-S.; Jacques, C.
1994-01-01
Time scales have been constructed in different ways to meet the many demands placed upon them for time accuracy, frequency accuracy, long-term stability, and robustness. Usually, no single time scale is optimum for all purposes. In the context of the impending availability of high-accuracy intermittently-operated cesium fountains, we reconsider the question of evaluating the accuracy of time scales which use an algorithm to span interruptions of the primary standard. We consider a broad class of calibration algorithms that can be evaluated and compared quantitatively for their accuracy in the presence of frequency drift and a full noise model (a mixture of white PM, flicker PM, white FM, flicker FM, and random walk FM noise). We present the analytic techniques for computing the standard uncertainty for the full noise model and this class of calibration algorithms. The simplest algorithm is evaluated to find the average-frequency uncertainty arising from the noise of the cesium fountain's local oscillator and from the noise of a hydrogen maser transfer-standard. This algorithm and known noise sources are shown to permit interlaboratory frequency transfer with a standard uncertainty of less than 10(exp -15) for periods of 30-100 days.
The effect of eccentricity and spatiotemporal energy on motion silencing.
Choi, Lark Kwon; Bovik, Alan C; Cormack, Lawrence K
2016-01-01
The now well-known motion-silencing illusion has shown that salient changes among a group of objects' luminances, colors, shapes, or sizes may appear to cease when objects move rapidly (Suchow & Alvarez, 2011). It has been proposed that silencing derives from dot spacing that causes crowding, coherent changes in object color or size, and flicker frequencies combined with dot spacing (Choi, Bovik, & Cormack, 2014; Peirce, 2013; Turi & Burr, 2013). Motion silencing is a peripheral effect that does not occur near the point of fixation. To better understand the effect of eccentricity on motion silencing, we measured the amount of motion silencing as a function of eccentricity in human observers using traditional psychophysics. Fifteen observers reported whether dots in any of four concentric rings changed in luminance over a series of rotational velocities. The results in the human experiments showed that the threshold velocity for motion silencing almost linearly decreases as a function of log eccentricity. Further, we modeled the response of a population of simulated V1 neurons to our stimuli. We found strong matches between the threshold velocities on motion silencing observed in the human experiment and those seen in the energy model of Adelson and Bergen (1985). We suggest the plausible explanation that as eccentricity increases, the combined motion-flicker signal falls outside the narrow spatiotemporal frequency response regions of the modeled receptive fields, thereby reducing flicker visibility.
NASA Astrophysics Data System (ADS)
Mootha, A.; Takanezawa, Y.; Iwasaka, M.
2018-05-01
The present study focused on the vibration of micro crystal particles of guanine due to Brownian motion. The organic particle has a refractive index of 1.83 and caused a flickering of light. To test the possibility of using magnetic properties under wet conditions, changes in the frequency of particle vibration by applying magnetic fields were investigated. At first, we found that the exposure at 5 T inhibited the flickering light intensities and the particle vibration slightly decreased. Next, we carried out a high speed camera measurement of the Brownian motion of the particle with a time resolution of 100 flame per second (fps) with and without magnetic field exposures. It was revealed that the vibrational speed of synthetic particles was enhanced at 500 mT. Detailed analyses of the particle vibration by changing the direction of magnetic fields versus the light source revealed that the Brownian motion's vibrational frequency was entrained under magnetic fields at 500 mT, and an increase in vibration speed to 20Hz was observed. Additional measurements of light scattering fluctuation using photo-detector and analyses on auto-correlation also confirmed this speculation. The studied Brownian vibration may be influenced by the change in mechanical interactions between the vibration particles and surrounding medium. The discovered phenomena can be applied for molecular and biological interactions in future studies.
NASA Astrophysics Data System (ADS)
Kleeberg, Florian P.; Gutzmann, Holger L.; Weyer, Cornelia; Weiß, Jürgen; Dörfler, Joachim; Hahlweg, Cornelius F.
2014-09-01
The present paper is a follow up of a paper presented in 2013 at the Novel Optical Systems conference in the session on Optics and Music. It is derived from an ongoing study on the human perception of combined optical and acoustical periodical stimuli. Originating from problems concerning artificial illumination and certain machinery with coherent optical and acoustical emissions there are effects to be observed which are interesting in the context of occupational medicine. It seems, that acoustic stimuli in the frequency range of the flicker fusion and below might lead to unexpected perceptible effects beyond those of the single stimuli. The effect of infrasound stimuli as a whole body perception seems to be boosted. Because of the difficulties in evaluation of physical and psychological effects of such coherent stimuli in a first step we question if such coherence is perceivable at all. Further, the problem of modulation of optical signals by acoustical signal is concerned. A catalogue of scenarios and 'effects to look for' including measurement concepts is presented and discussed.
Langbein, John O.
2012-01-01
Recent studies have documented that global positioning system (GPS) time series of position estimates have temporal correlations which have been modeled as a combination of power-law and white noise processes. When estimating quantities such as a constant rate from GPS time series data, the estimated uncertainties on these quantities are more realistic when using a noise model that includes temporal correlations than simply assuming temporally uncorrelated noise. However, the choice of the specific representation of correlated noise can affect the estimate of uncertainty. For many GPS time series, the background noise can be represented by either: (1) a sum of flicker and random-walk noise or, (2) as a power-law noise model that represents an average of the flicker and random-walk noise. For instance, if the underlying noise model is a combination of flicker and random-walk noise, then incorrectly choosing the power-law model could underestimate the rate uncertainty by a factor of two. Distinguishing between the two alternate noise models is difficult since the flicker component can dominate the assessment of the noise properties because it is spread over a significant portion of the measurable frequency band. But, although not necessarily detectable, the random-walk component can be a major constituent of the estimated rate uncertainty. None the less, it is possible to determine the upper bound on the random-walk noise.
Wind turbines and human health.
Knopper, Loren D; Ollson, Christopher A; McCallum, Lindsay C; Whitfield Aslund, Melissa L; Berger, Robert G; Souweine, Kathleen; McDaniel, Mary
2014-01-01
The association between wind turbines and health effects is highly debated. Some argue that reported health effects are related to wind turbine operation [electromagnetic fields (EMF), shadow flicker, audible noise, low-frequency noise, infrasound]. Others suggest that when turbines are sited correctly, effects are more likely attributable to a number of subjective variables that result in an annoyed/stressed state. In this review, we provide a bibliographic-like summary and analysis of the science around this issue specifically in terms of noise (including audible, low-frequency noise, and infrasound), EMF, and shadow flicker. Now there are roughly 60 scientific peer-reviewed articles on this issue. The available scientific evidence suggests that EMF, shadow flicker, low-frequency noise, and infrasound from wind turbines are not likely to affect human health; some studies have found that audible noise from wind turbines can be annoying to some. Annoyance may be associated with some self-reported health effects (e.g., sleep disturbance) especially at sound pressure levels >40 dB(A). Because environmental noise above certain levels is a recognized factor in a number of health issues, siting restrictions have been implemented in many jurisdictions to limit noise exposure. These setbacks should help alleviate annoyance from noise. Subjective variables (attitudes and expectations) are also linked to annoyance and have the potential to facilitate other health complaints via the nocebo effect. Therefore, it is possible that a segment of the population may remain annoyed (or report other health impacts) even when noise limits are enforced. Based on the findings and scientific merit of the available studies, the weight of evidence suggests that when sited properly, wind turbines are not related to adverse health. Stemming from this review, we provide a number of recommended best practices for wind turbine development in the context of human health.
Wind Turbines and Human Health
Knopper, Loren D.; Ollson, Christopher A.; McCallum, Lindsay C.; Whitfield Aslund, Melissa L.; Berger, Robert G.; Souweine, Kathleen; McDaniel, Mary
2014-01-01
The association between wind turbines and health effects is highly debated. Some argue that reported health effects are related to wind turbine operation [electromagnetic fields (EMF), shadow flicker, audible noise, low-frequency noise, infrasound]. Others suggest that when turbines are sited correctly, effects are more likely attributable to a number of subjective variables that result in an annoyed/stressed state. In this review, we provide a bibliographic-like summary and analysis of the science around this issue specifically in terms of noise (including audible, low-frequency noise, and infrasound), EMF, and shadow flicker. Now there are roughly 60 scientific peer-reviewed articles on this issue. The available scientific evidence suggests that EMF, shadow flicker, low-frequency noise, and infrasound from wind turbines are not likely to affect human health; some studies have found that audible noise from wind turbines can be annoying to some. Annoyance may be associated with some self-reported health effects (e.g., sleep disturbance) especially at sound pressure levels >40 dB(A). Because environmental noise above certain levels is a recognized factor in a number of health issues, siting restrictions have been implemented in many jurisdictions to limit noise exposure. These setbacks should help alleviate annoyance from noise. Subjective variables (attitudes and expectations) are also linked to annoyance and have the potential to facilitate other health complaints via the nocebo effect. Therefore, it is possible that a segment of the population may remain annoyed (or report other health impacts) even when noise limits are enforced. Based on the findings and scientific merit of the available studies, the weight of evidence suggests that when sited properly, wind turbines are not related to adverse health. Stemming from this review, we provide a number of recommended best practices for wind turbine development in the context of human health. PMID:24995266
Retinal Vascular and Oxygen Temporal Dynamic Responses to Light Flicker in Humans
Felder, Anthony E.; Wanek, Justin; Blair, Norman P.
2017-01-01
Purpose To mathematically model the temporal dynamic responses of retinal vessel diameter (D), oxygen saturation (SO2), and inner retinal oxygen extraction fraction (OEF) to light flicker and to describe their responses to its cessation in humans. Methods In 16 healthy subjects (age: 60 ± 12 years), retinal oximetry was performed before, during, and after light flicker stimulation. At each time point, five metrics were measured: retinal arterial and venous D (DA, DV) and SO2 (SO2A, SO2V), and OEF. Intra- and intersubject variability of metrics was assessed by coefficient of variation of measurements before flicker within and among subjects, respectively. Metrics during flicker were modeled by exponential functions to determine the flicker-induced steady state metric values and the time constants of changes. Metrics after the cessation of flicker were compared to those before flicker. Results Intra- and intersubject variability for all metrics were less than 6% and 16%, respectively. At the flicker-induced steady state, DA and DV increased by 5%, SO2V increased by 7%, and OEF decreased by 13%. The time constants of DA and DV (14, 15 seconds) were twofold smaller than those of SO2V and OEF (39, 34 seconds). Within 26 seconds after the cessation of flicker, all metrics were not significantly different from before flicker values (P ≥ 0.07). Conclusions Mathematical modeling revealed considerable differences in the time courses of changes among metrics during flicker, indicating flicker duration should be considered separately for each metric. Future application of this method may be useful to elucidate alterations in temporal dynamic responses to light flicker due to retinal diseases. PMID:29098297
The effect of hypoxia on the critical flicker fusion threshold in pilots.
Truszczyński, Olaf; Wojtkowiak, Mieczysław; Biernacki, Marcin; Kowalczuk, Krzysztof
2009-01-01
Human reactions to environmental changes have been the subject of numerous investigations related to pathophysiology, aviation psychology, aviation, and sports. The present study aimed at evaluating the perception of light stimulus via the Critical Flicker Fusion threshold (CFF) measurements among aviation pilots. The study was carried out under hypoxic conditions corresponding to 5000 m altitude, for a period of 30 min, without the use of supplemental oxygen. Fourteen volunteer pilots, 23-30 years of age, were examined in the hypobaric chamber (HC). The measurements were performed at normobaria and at the initial and final phase of hypoxia. Heart rate (HR) and blood oxygen saturation (SaO2) were monitored. The high altitude hypoxia was found to produce a decrease in the CFF threshold F(3.39) = 3.207, p < 0.05, and SaO2 F(3.39) = 52.651, p < 0.001, as well as HR increase F(3.39) = 7.356, p < 0.001. The results indicate that the higher the decrease in SaO2 under hypoxic conditions, the higher the decrease in CFF r = .567 p < 0.05. Likewise, the higher the increase in HR, the higher the decrease in CFF r = -0.491 p < 0.05. Under hypoxic conditions, the perceptual ability of the pilots is gradually decreasing. This has been confirmed by the findings of the physiological examinations. The authors express an opinion that it would be advisable to introduce CFF measurement into the hypobaric chamber tests as it allows individual assessment of the pilot's perceptual ability under conditions of incomplete physiological compensation of the high altitude hypoxia.
NASA Astrophysics Data System (ADS)
Maekawa, Keiichi; Makiyama, Hideki; Yamamoto, Yoshiki; Hasegawa, Takumi; Okanishi, Shinobu; Sonoda, Kenichiro; Shinkawata, Hiroki; Yamashita, Tomohiro; Kamohara, Shiro; Yamaguchi, Yasuo
2018-04-01
The low-frequency noise (LFN) variability in bulk and fully depleted silicon-on-insulator (FDSOI) metal–oxide–semiconductor field-effect transistor (MOSFET) with silicon on thin box (SOTB) technology was investigated. LFN typically shows a flicker noise component and a signal Lorentzian component by random telegraph noise (RTN). At a weak inversion state, the random dopant fluctuation (RDF) in a channel is strongly affected to not only RTN variability but also flicker noise variability in the bulk MOSFET compared with SOTB MOSFET because of local carrier number fluctuation in the channel. On the other hand, the typical level of LFN in SOTB MOSFET is slightly larger than that in the bulk MOSFET because of an additional interface on the buried oxide layer. However, considering the tailing characteristics of LFN variability, LFN in SOTB MOSFET can be assumed to be smaller than that in the bulk MOSFET, which enables the low-voltage operation of analog circuits.
Reducing flicker due to ambient illumination in camera captured images
NASA Astrophysics Data System (ADS)
Kim, Minwoong; Bengtson, Kurt; Li, Lisa; Allebach, Jan P.
2013-02-01
The flicker artifact dealt with in this paper is the scanning distortion arising when an image is captured by a digital camera using a CMOS imaging sensor with an electronic rolling shutter under strong ambient light sources powered by AC. This type of camera scans a target line-by-line in a frame. Therefore, time differences exist between the lines. This mechanism causes a captured image to be corrupted by the change of illumination. This phenomenon is called the flicker artifact. The non-content area of the captured image is used to estimate a flicker signal that is a key to being able to compensate the flicker artifact. The average signal of the non-content area taken along the scan direction has local extrema where the peaks of flicker exist. The locations of the extrema are very useful information to estimate the desired distribution of pixel intensities assuming that the flicker artifact does not exist. The flicker-reduced images compensated by our approach clearly demonstrate the reduced flicker artifact, based on visual observation.
Kim, MinSu; Ham, Hyeong Gyun; Choi, Han-Sol; Bos, Philip J; Yang, Deng-Ke; Lee, Joong Hee; Lee, Seung Hee
2017-03-20
The demands for a power-saving mode for displaying static images are ubiquitous not only in portable devices but also in price tags and advertising panels. At a low-frequency driving in liquid crystal displays (LCDs) for low-power consumption, the flexoelectric effect arises even in calamitic liquid crystals and the optical appearance of this physical phenomenon is found to be unusually large, being noticed as an image-flickering. Although the inherent integrated optical transmittance of in-plane switching (IPS) mode is relatively lower than that of fringe-field switching (FFS) mode, the IPS mode shows no static image-flickering but an optical spike (the so-called optical bounce), at the transient moment between signal positive and negative frames. Here, we demonstrate an IPS mode using negative dielectric anisotropy of liquid crystals (Δε < 0) and fine-patterned electrodes (the width w of and the space l between electrodes ≤ 3 μm) with reduced operation voltage (up to 40.7% to a conventional FFS mode with Δε < 0), reduced optical bounce (up to 4.4%. to a conventional FFS mode with Δε < 0) and enhanced transmittance (up to 32.1% to a conventional IPS mode with Δε > 0). We believe the result will contribute not only to the scientific understanding of the optical appearance of flexoelectric effect but also pave the way for engineering of a superior low-power consumption LCD.
Nikolaus, Joerg; Karatekin, Erdem
2016-01-01
In the ubiquitous process of membrane fusion the opening of a fusion pore establishes the first connection between two formerly separate compartments. During neurotransmitter or hormone release via exocytosis, the fusion pore can transiently open and close repeatedly, regulating cargo release kinetics. Pore dynamics also determine the mode of vesicle recycling; irreversible resealing results in transient, "kiss-and-run" fusion, whereas dilation leads to full fusion. To better understand what factors govern pore dynamics, we developed an assay to monitor membrane fusion using polarized total internal reflection fluorescence (TIRF) microscopy with single molecule sensitivity and ~15 msec time resolution in a biochemically well-defined in vitro system. Fusion of fluorescently labeled small unilamellar vesicles containing v-SNARE proteins (v-SUVs) with a planar bilayer bearing t-SNAREs, supported on a soft polymer cushion (t-SBL, t-supported bilayer), is monitored. The assay uses microfluidic flow channels that ensure minimal sample consumption while supplying a constant density of SUVs. Exploiting the rapid signal enhancement upon transfer of lipid labels from the SUV to the SBL during fusion, kinetics of lipid dye transfer is monitored. The sensitivity of TIRF microscopy allows tracking single fluorescent lipid labels, from which lipid diffusivity and SUV size can be deduced for every fusion event. Lipid dye release times can be much longer than expected for unimpeded passage through permanently open pores. Using a model that assumes retardation of lipid release is due to pore flickering, a pore "openness", the fraction of time the pore remains open during fusion, can be estimated. A soluble marker can be encapsulated in the SUVs for simultaneous monitoring of lipid and soluble cargo release. Such measurements indicate some pores may reseal after losing a fraction of the soluble cargo. PMID:27585113
Cellular imaging using temporally flickering nanoparticles.
Ilovitsh, Tali; Danan, Yossef; Meir, Rinat; Meiri, Amihai; Zalevsky, Zeev
2015-02-04
Utilizing the surface plasmon resonance effect in gold nanoparticles enables their use as contrast agents in a variety of applications for compound cellular imaging. However, most techniques suffer from poor signal to noise ratio (SNR) statistics due to high shot noise that is associated with low photon count in addition to high background noise. We demonstrate an effective way to improve the SNR, in particular when the inspected signal is indistinguishable in the given noisy environment. We excite the temporal flickering of the scattered light from gold nanoparticle that labels a biological sample. By preforming temporal spectral analysis of the received spatial image and by inspecting the proper spectral component corresponding to the modulation frequency, we separate the signal from the wide spread spectral noise (lock-in amplification).
Huang, Kuo-Chen; Chiang, Shu-Ying; Chen, Chen-Fu
2008-02-01
The effects of color combinations of an icon's symbol/background and components of flicker and flicker rate on visual search performance on a liquid crystal display screen were investigated with 39 subjects who searched for a target icon in a circular stimulus array (diameter = 20 cm) including one target and 19 distractors. Analysis showed that the icon's symbol/background color significantly affected search time. The search times for icons with black/red and white/blue were significantly shorter than for white/yellow, black/yellow, and black/blue. Flickering of different components of the icon significantly affected the search time. Search time for an icon's border flickering was shorter than for an icon symbol flickering; search for flicker rates of 3 and 5 Hz was shorter than that for 1 Hz. For icon's symbol/background color combinations, search error rate for black/blue was greater than for black/red and white/blue combinations, and the error rate for an icon's border flickering was lower than for an icon's symbol flickering. Interactions affected search time and error rate. Results are applicable to design of graphic user interfaces.
A Benchmark Dataset for SSVEP-Based Brain-Computer Interfaces.
Wang, Yijun; Chen, Xiaogang; Gao, Xiaorong; Gao, Shangkai
2017-10-01
This paper presents a benchmark steady-state visual evoked potential (SSVEP) dataset acquired with a 40-target brain- computer interface (BCI) speller. The dataset consists of 64-channel Electroencephalogram (EEG) data from 35 healthy subjects (8 experienced and 27 naïve) while they performed a cue-guided target selecting task. The virtual keyboard of the speller was composed of 40 visual flickers, which were coded using a joint frequency and phase modulation (JFPM) approach. The stimulation frequencies ranged from 8 Hz to 15.8 Hz with an interval of 0.2 Hz. The phase difference between two adjacent frequencies was . For each subject, the data included six blocks of 40 trials corresponding to all 40 flickers indicated by a visual cue in a random order. The stimulation duration in each trial was five seconds. The dataset can be used as a benchmark dataset to compare the methods for stimulus coding and target identification in SSVEP-based BCIs. Through offline simulation, the dataset can be used to design new system diagrams and evaluate their BCI performance without collecting any new data. The dataset also provides high-quality data for computational modeling of SSVEPs. The dataset is freely available fromhttp://bci.med.tsinghua.edu.cn/download.html.
Rosen, Hannah; Gilly, William; Bell, Lauren; Abernathy, Kyler; Marshall, Greg
2015-01-15
Dosidicus gigas (Humboldt or jumbo flying squid) is an economically and ecologically influential species, yet little is known about its natural behaviors because of difficulties in studying this active predator in its oceanic environment. By using an animal-borne video package, National Geographic's Crittercam, we were able to observe natural behaviors in free-swimming D. gigas in the Gulf of California with a focus on color-generating (chromogenic) behaviors. We documented two dynamic displays without artificial lighting at depths of up to 70 m. One dynamic pattern, termed 'flashing' is characterized by a global oscillation (2-4 Hz) of body color between white and red. Flashing was almost always observed when other squid were visible in the video frame, and this behavior presumably represents intraspecific signaling. Amplitude and frequency of flashing can be modulated, and the phase relationship with another squid can also be rapidly altered. Another dynamic display termed 'flickering' was observed whenever flashing was not occurring. This behavior is characterized by irregular wave-like activity in neighboring patches of chromatophores, and the resulting patterns mimic reflections of down-welled light in the water column, suggesting that this behavior may provide a dynamic type of camouflage. Rapid and global pauses in flickering, often before a flashing episode, indicate that flickering is under inhibitory neural control. Although flashing and flickering have not been described in other squid, functional similarities are evident with other species. © 2015. Published by The Company of Biologists Ltd.
Zopiclone as a preoperative night hypnotic: a double-blind comparison with temazepam and placebo.
Whitehead, C; Sanders, L; Appadurai, I; Power, I; Rosen, M; Robinson, J
1994-04-01
We have examined the hypnotic effects of zopiclone 7.5 mg and temazepam 20 mg compared with placebo in a double-blind, randomized, clinical study of 60 patients on the night before operation. Evaluation was both subjective (visual analogue scales and a sleep questionnaire), to measure the quality of sleep, and objective (critical flicker fusion, object recall and paired associates tasks), to measure residual impairment. We found that zopiclone was an effective single-dose hypnotic with similar residual effects to the benzodiazepine and it may therefore provide a suitable alternative to benzodiazepines.
Field Theoretic Study of Bilayer Membrane Fusion. I. Hemifusion Mechanism
Katsov, K.; Müller, M.; Schick, M.
2004-01-01
Self-consistent field theory is used to determine structural and energetic properties of metastable intermediates and unstable transition states involved in the standard stalk mechanism of bilayer membrane fusion. A microscopic model of flexible amphiphilic chains dissolved in hydrophilic solvent is employed to describe these self-assembled structures. We find that the barrier to formation of the initial stalk is much smaller than previously estimated by phenomenological theories. Therefore its creation it is not the rate-limiting process. The relevant barrier is associated with the rather limited radial expansion of the stalk into a hemifusion diaphragm. It is strongly affected by the architecture of the amphiphile, decreasing as the effective spontaneous curvature of the amphiphile is made more negative. It is also reduced when the tension is increased. At high tension the fusion pore, created when a hole forms in the hemifusion diaphragm, expands without bound. At very low membrane tension, small fusion pores can be trapped in a flickering metastable state. Successful fusion is severely limited by the architecture of the lipids. If the effective spontaneous curvature is not sufficiently negative, fusion does not occur because metastable stalks, whose existence is a seemingly necessary prerequisite, do not form at all. However if the spontaneous curvature is too negative, stalks are so stable that fusion does not occur because the system is unstable either to a phase of stable radial stalks, or to an inverted-hexagonal phase induced by stable linear stalks. Our results on the architecture and tension needed for successful fusion are summarized in a phase diagram. PMID:15326031
Optical flickering of the symbiotic star CH Cyg
NASA Astrophysics Data System (ADS)
Stoyanov, K. A.; Martí, J.; Zamanov, R.; Dimitrov, V. V.; Kurtenkov, A.; Sánchez-Ayaso, E.; Bujalance-Fernández, I.; Latev, G. Y.; Nikolov, G.
2018-02-01
Here we present quasi-simultaneous observations of the flickering of the symbiotic binary star CH Cyg in U, B and V bands. We calculate the flickering source parameters and discuss the possible reason for the flickering cessation in the period 2010-2013.
Improvement of Frequency Locking Algorithm for Atomic Frequency Standards
NASA Astrophysics Data System (ADS)
Park, Young-Ho; Kang, Hoonsoo; Heyong Lee, Soo; Eon Park, Sang; Lee, Jong Koo; Lee, Ho Seong; Kwon, Taeg Yong
2010-09-01
The authors describe a novel method of frequency locking algorithm for atomic frequency standards. The new algorithm for locking the microwave frequency to the Ramsey resonance is compared with the old one that had been employed in the cesium atomic beam frequency standards such as NIST-7 and KRISS-1. Numerical simulations for testing the performance of the algorithm show that the new method has a noise filtering performance superior to the old one by a factor of 1.2 for the flicker signal noise and 1.4 for random-walk signal noise. The new algorithm can readily be used to enhance the frequency stability for a digital servo employing the slow square wave frequency modulation.
Attractive Flicker--Guiding Attention in Dynamic Narrative Visualizations.
Waldner, Manuela; Le Muzic, Mathieu; Bernhard, Matthias; Purgathofer, Werner; Viola, Ivan
2014-12-01
Focus+context techniques provide visual guidance in visualizations by giving strong visual prominence to elements of interest while the context is suppressed. However, finding a visual feature to enhance for the focus to pop out from its context in a large dynamic scene, while leading to minimal visual deformation and subjective disturbance, is challenging. This paper proposes Attractive Flicker, a novel technique for visual guidance in dynamic narrative visualizations. We first show that flicker is a strong visual attractor in the entire visual field, without distorting, suppressing, or adding any scene elements. The novel aspect of our Attractive Flicker technique is that it consists of two signal stages: The first "orientation stage" is a short but intensive flicker stimulus to attract the attention to elements of interest. Subsequently, the intensive flicker is reduced to a minimally disturbing luminance oscillation ("engagement stage") as visual support to keep track of the focus elements. To find a good trade-off between attraction effectiveness and subjective annoyance caused by flicker, we conducted two perceptual studies to find suitable signal parameters. We showcase Attractive Flicker with the parameters obtained from the perceptual statistics in a study of molecular interactions. With Attractive Flicker, users were able to easily follow the narrative of the visualization on a large display, while the flickering of focus elements was not disturbing when observing the context.
Influence of viewing distance and size of tv on visual fatigue and feeling of involvement.
Sakamoto, Kiyomi; Asahara, Shigeo; Yamashita, Kuniko; Okada, Akira
2012-12-01
Using physiological and psychological measurements, we carried out experiments to investigate the influence of viewing distance and TV screen size on visual fatigue and feeling of involvement using 17-inch, 42-inch and 65-inch displays. The experiment was an ordinary viewing test with the content similar to everyday TV programs for one hour including scenery, sport, drama, etc., with commercials sandwiched in between. The number of participants was 16 (8 persons aged 21-31, and 8 persons aged 50-70) for each display size. In all, 48 participants viewed 3 display sizes. In our physiological evaluation, CFF (critical flicker fusion frequency), blink rate and a sympathetic nerve activity index were used; and in the psychological evaluation, questionnaires and interviews were employed. Our results, based on physiological and psychological measurements, suggest the opti- mum viewing distance to be around 165-220 cm, irrespective of screen size. Our evaluations, which are based on optimum viewing distance for minimal visual fatigue and a closer feeling of involvement, might therefore not agree with the currently recommended viewing distance, which is defined as 2 or 3 times the display's height.
Patat, A; Perault, M C; Vandel, B; Ulliac, N; Zieleniuk, I; Rosenzweig, P
1995-01-01
1. The possible interaction between a new H1 antihistamine, mizolastine, and lorazepam was assessed in a randomised, double-blind, cross-over, placebo-controlled study involving 16 healthy young male volunteers who received mizolastine 10 mg or placebo once daily for 8 days with a 1 week wash-out interval. The interaction of mizolastine, at steady-state, with a single oral dose of lorazepam or placebo was assessed on days 6 or 8 of each treatment period. 2. Psychomotor performance and cognitive function were evaluated using objective tests (critical flicker fusion threshold, choice reaction time, tapping, arithmetic calculation, body sway) and self-ratings (visual analogue scale, ARCI) before and at 2, 4, 6 and 8 h after dosing. Short-term memory (Sternberg memory scanning immediate free recall of a word list) and long-term memory (delayed free recall and recognition of words and pictures) were assessed before and at 3 h after dosing. Pharmacodynamic interactions were evaluated by repeated measures ANOVA in a 2 x 2 factorial interaction model. 3. Mizolastine, 10 mg once daily, at steady-state, was devoid of sedation and detrimental effect on skilled performance and memory. 4. In contrast, a single 2 mg dose of lorazepam produced marked impairment of psychomotor performance, cognitive functions (significant reduction in flicker fusion threshold, tapping and arithmetic calculation and increase in reaction times and body sway) and subjective sedation from 2 to 8 h after dosing. In addition, lorazepam induced an anterograde amnesia, characterised by a decrease in delayed free recall and recognition, and a deficit in short term memory.(ABSTRACT TRUNCATED AT 250 WORDS)
Food habits of Northern Goshawks nesting in south central Wyoming
John R. Squires
2000-01-01
Northern Goshawks (Accipiter gentiles) nesting in south central Wyoming consumed at least 33 species of prey; 14 were mammals and 19 were birds. Based on percent occurrence in regurgitated pellets, dominant (>10% frequency) prey species included: red squirrel (Tamiasciurus hudsonicus; present in 50% of pellets), Northern Flicker (Colaptes auratus; 34...
Local Positioning System Using Flickering Infrared LEDs
Raharijaona, Thibaut; Mawonou, Rodolphe; Nguyen, Thanh Vu; Colonnier, Fabien; Boyron, Marc; Diperi, Julien; Viollet, Stéphane
2017-01-01
A minimalistic optical sensing device for the indoor localization is proposed to estimate the relative position between the sensor and active markers using amplitude modulated infrared light. The innovative insect-based sensor can measure azimuth and elevation angles with respect to two small and cheap active infrared light emitting diodes (LEDs) flickering at two different frequencies. In comparison to a previous lensless visual sensor that we proposed for proximal localization (less than 30 cm), we implemented: (i) a minimalistic sensor in terms of small size (10 cm3), light weight (6 g) and low power consumption (0.4 W); (ii) an Arduino-compatible demodulator for fast analog signal processing requiring low computational resources; and (iii) an indoor positioning system for a mobile robotic application. Our results confirmed that the proposed sensor was able to estimate the position at a distance of 2 m with an accuracy as small as 2-cm at a sampling frequency of 100 Hz. Our sensor can be also suitable to be implemented in a position feedback loop for indoor robotic applications in GPS-denied environment. PMID:29099743
Stellar granulation as the source of high-frequency flicker in Kepler light curves
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cranmer, Steven R.; Saar, Steven H.; Bastien, Fabienne A.
2014-02-01
A large fraction of cool, low-mass stars exhibit brightness fluctuations that arise from a combination of convective granulation, acoustic oscillations, magnetic activity, and stellar rotation. Much of the short-timescale variability takes the form of stochastic noise, whose presence may limit the progress of extrasolar planet detection and characterization. In order to lay the groundwork for extracting useful information from these quasi-random signals, we focus on the origin of the granulation-driven component of the variability. We apply existing theoretical scaling relations to predict the star-integrated variability amplitudes for 508 stars with photometric light curves measured by the Kepler mission. We alsomore » derive an empirical correction factor that aims to account for the suppression of convection in F-dwarf stars with magnetic activity and shallow convection zones. So that we can make predictions of specific observational quantities, we performed Monte Carlo simulations of granulation light curves using a Lorentzian power spectrum. These simulations allowed us to reproduce the so-called flicker floor (i.e., a lower bound in the relationship between the full light-curve range and power in short-timescale fluctuations) that was found in the Kepler data. The Monte Carlo model also enabled us to convert the modeled fluctuation variance into a flicker amplitude directly comparable with observations. When the magnetic suppression factor described above is applied, the model reproduces the observed correlation between stellar surface gravity and flicker amplitude. Observationally validated models like these provide new and complementary evidence for a possible impact of magnetic activity on the properties of near-surface convection.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2013-03-01
Solid-state lighting program technology fact sheet that discusses flicker metrics, contributing factors, and consequences in addition to comparing the flicker attributes of a sample of conventional and LED sources.
Judder-Induced Edge Flicker at Zero Spatial Contrast
NASA Technical Reports Server (NTRS)
Larimer, James; Feng, Christine; Gille, Jennifer; Cheung, Victor
2004-01-01
Judder is a motion artifact that degrades the quality of video imagery. Smooth motion appears jerky and can appear to flicker along the leading and trailing edge of the moving object. In a previous paper, we demonstrated that the strength of the edge flicker signal depended upon the brightness of the scene and the contrast of the moving object relative to the background. Reducing the contrast between foreground and background reduced the flicker signal. In this report, we show that the contrast signal required for judder-induced edge flicker is due to temporal contrast and not simply to spatial contrast. Bars made of random dots of the same dot density as the background exhibit edge flicker when moved at sufficient rate.
Lewis, Ashley Glen; Schriefers, Herbert; Bastiaansen, Marcel; Schoffelen, Jan-Mathijs
2018-05-21
Reinstatement of memory-related neural activity measured with high temporal precision potentially provides a useful index for real-time monitoring of the timing of activation of memory content during cognitive processing. The utility of such an index extends to any situation where one is interested in the (relative) timing of activation of different sources of information in memory, a paradigm case of which is tracking lexical activation during language processing. Essential for this approach is that memory reinstatement effects are robust, so that their absence (in the average) definitively indicates that no lexical activation is present. We used electroencephalography to test the robustness of a reported subsequent memory finding involving reinstatement of frequency-specific entrained oscillatory brain activity during subsequent recognition. Participants learned lists of words presented on a background flickering at either 6 or 15 Hz to entrain a steady-state brain response. Target words subsequently presented on a non-flickering background that were correctly identified as previously seen exhibited reinstatement effects at both entrainment frequencies. Reliability of these statistical inferences was however critically dependent on the approach used for multiple comparisons correction. We conclude that effects are not robust enough to be used as a reliable index of lexical activation during language processing.
Chen, Jing; Valsecchi, Matteo; Gegenfurtner, Karl R
2017-07-28
It is under debate whether attention during smooth pursuit is centered right on the pursuit target or allocated preferentially ahead of it. Attentional deployment was previously probed using a secondary task, which might have altered attention allocation and led to inconsistent findings. We measured frequency-tagged steady-state visual evoked potentials (SSVEP) to measure attention allocation in the absence of any secondary probing task. The observers pursued a moving dot while stimuli flickering at different frequencies were presented at various locations ahead or behind the pursuit target. We observed a significant increase in EEG power at the flicker frequency of the stimulus in front of the pursuit target, compared to the frequency of the stimulus behind. When testing many different locations, we found that the enhancement was detectable up to about 1.5° ahead during pursuit, but vanished by 3.5°. In a control condition using attentional cueing during fixation, we did observe an enhanced EEG response to stimuli at this eccentricity, indicating that the focus of attention during pursuit is narrower than allowed for by the resolution of the attentional system. In a third experiment, we ruled out the possibility that the SSVEP enhancement was a byproduct of the catch-up saccades occurring during pursuit. Overall, we showed that attention is on average allocated ahead of the pursuit target during smooth pursuit. EEG frequency tagging seems to be a powerful technique that allows for the investigation of attention/perception implicitly when an overt task would be confounding. Copyright © 2017 Elsevier Ltd. All rights reserved.
Effects of Constant Flickering Light on Refractive Status, 5-HT and 5-HT2A Receptor in Guinea Pigs.
Li, Bing; Luo, Xiumei; Li, Tao; Zheng, Changyue; Ji, Shunmei; Ma, Yuanyuan; Zhang, Shuangshuang; Zhou, Xiaodong
2016-01-01
To investigate the effects of constant flickering light on refractive development, the role of serotonin (i.e.5-hydroxytryptamine, 5-HT)and 5-HT2A receptor in myopia induced by flickering light in guinea pigs. Forty-five guinea pigs were randomly divided into three groups: control, form deprivation myopia (FDM) and flickering light induced myopia (FLM) groups(n = 15 for each group). The right eyes of the FDM group were covered with semitransparent hemispherical plastic shells serving as eye diffusers. Guinea pigs in FLM group were raised with illumination of a duty cycle of 50% at a flash frequency of 0.5Hz. The refractive status, axial length (AL), corneal radius of curvature(CRC) were measured by streak retinoscope, A-scan ultrasonography and keratometer, respectively. Ultramicroscopy images were taken by electron microscopy. The concentrations of 5-HTin the retina, vitreous body and retinal pigment epithelium (RPE) were assessed by high performance liquid chromatography, the retinal 5-HT2A receptor expression was evaluated by immunohistofluorescence and western blot. The refraction of FDM and FLM eyes became myopic from some time point (the 4th week and the 6th week, respectively) in the course of the experiment, which was indicated by significantly decreased refraction and longer AL when compared with the controls (p<0.05). The concentrations of 5-HT in the retina, vitreous body and RPE of FDM and FLM eyes were significantly increased in comparison with those of control eyes (both p<0.05). Similar to FDM eyes, the expression of retinal 5-HT2A receptor in FLM eyes was significantly up-regulated compared to that of control eyes (both p<0.05). Western blot analysis showed that retinal 5-HT2A receptor level elevated less in the FLM eyes than that in the FDM eyes. Moreover, the levels of norepinephrine and epinephrine in FDM and FLM groups generally decreased when compared with control groups (all p<0.05). Constant flickering light could cause progressive myopia in guinea pigs. 5-HT and 5-HT2A receptor increased both in form deprivation myopia and flickering light induced myopia, indicating that 5-HT possibly involved in myopic development via binding to5-HT2A receptor.
Effects of Constant Flickering Light on Refractive Status, 5-HT and 5-HT2A Receptor in Guinea Pigs
Li, Tao; Zheng, Changyue; Ji, Shunmei; Ma, Yuanyuan; Zhang, Shuangshuang; Zhou, Xiaodong
2016-01-01
Purpose To investigate the effects of constant flickering light on refractive development, the role of serotonin (i.e.5-hydroxytryptamine, 5-HT)and 5-HT2A receptor in myopia induced by flickering light in guinea pigs. Methods Forty-five guinea pigs were randomly divided into three groups: control, form deprivation myopia (FDM) and flickering light induced myopia (FLM) groups(n = 15 for each group). The right eyes of the FDM group were covered with semitransparent hemispherical plastic shells serving as eye diffusers. Guinea pigs in FLM group were raised with illumination of a duty cycle of 50% at a flash frequency of 0.5Hz. The refractive status, axial length (AL), corneal radius of curvature(CRC) were measured by streak retinoscope, A-scan ultrasonography and keratometer, respectively. Ultramicroscopy images were taken by electron microscopy. The concentrations of 5-HTin the retina, vitreous body and retinal pigment epithelium (RPE) were assessed by high performance liquid chromatography, the retinal 5-HT2A receptor expression was evaluated by immunohistofluorescence and western blot. Results The refraction of FDM and FLM eyes became myopic from some time point (the 4th week and the 6th week, respectively) in the course of the experiment, which was indicated by significantly decreased refraction and longer AL when compared with the controls (p<0.05). The concentrations of 5-HT in the retina, vitreous body and RPE of FDM and FLM eyes were significantly increased in comparison with those of control eyes (both p<0.05). Similar to FDM eyes, the expression of retinal 5-HT2A receptor in FLM eyes was significantly up-regulated compared to that of control eyes (both p<0.05). Western blot analysis showed that retinal 5-HT2A receptor level elevated less in the FLM eyes than that in the FDM eyes. Moreover, the levels of norepinephrine and epinephrine in FDM and FLM groups generally decreased when compared with control groups (all p<0.05). Conclusions Constant flickering light could cause progressive myopia in guinea pigs. 5-HT and 5-HT2A receptor increased both in form deprivation myopia and flickering light induced myopia, indicating that 5-HT possibly involved in myopic development via binding to5-HT2A receptor. PMID:27959948
Effect of carbon monoxide exposure on human sleep and psychomotor performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
O'Donnell, R.D.; Chikos, P.; Theodore, J.
1971-01-01
Four volunteers exposed for 9 hr (11 p.m. to 8 a.m.) to 75 or 150 ppM CO had COHb concentrations of 5.9 and 12.7%, respectively. Sleep habits and subsequent performance were measured. CO induced slight changes in sleeping habits including more deep sleep at expense of light sleep (especially at beginning of exposure) and a reduction in number of sleep stage changes. However, REM sleep was not affected. No effect of CO on complex cognitive or psychromotor activity measured by mental arithmetic, time estimation, tracking and monitoring under moderate or heavy stress, tone-time difference estimation, and critical flicker fusion tests.
Zero energy-storage ballast for compact fluorescent lamps
Schultz, W.N.; Thomas, R.J.
1999-08-31
A CFL ballast includes complementary-type switching devices connected in series with their gates connected together at a control node. The switching devices supply a resonant tank circuit which is tuned to a frequency near, but slightly lower than, the resonant frequency of a resonant control circuit. As a result, the tank circuit restarts oscillations immediately following each zero crossing of the bus voltage. Such rapid restarts avoid undesirable flickering while maintaining the operational advantages and high efficacy of the CFL ballast. 4 figs.
Zero energy-storage ballast for compact fluorescent lamps
Schultz, William Newell; Thomas, Robert James
1999-01-01
A CFL ballast includes complementary-type switching devices connected in series with their gates connected together at a control node. The switching devices supply a resonant tank circuit which is tuned to a frequency near, but slightly lower than, the resonant frequency of a resonant control circuit. As a result, the tank circuit restarts oscillations immediately following each zero crossing of the bus voltage. Such rapid restarts avoid undesirable flickering while maintaining the operational advantages and high efficacy of the CFL ballast.
NASA Technical Reports Server (NTRS)
Binkley, D. M.; Hopper, C. E.; Cressler, J. D.; Mojarradi, M. M.; Blalock, B. J.
2004-01-01
This paper presents measured noise for 0.35(mu)m, silicon-on-insulator devices and a micropower preamplifier following 63-MeV, 1-Mrad (Si) proton irradiation. Flicker noise voltage, important for gyros having low frequency output, increases less than 32% after irradiation.
Chicks use changes in luminance and chromatic contrast as indicators of the sign of defocus
Rucker, Frances J.; Wallman, Josh
2012-01-01
As the eye changes focus, the resulting changes in cone contrast are associated with changes in color and luminance. Color fluctuations should simulate the eye being hyperopic and make the eye grow in the myopic direction, while luminance fluctuations should simulate myopia and make the eye grow in the hyperopic direction. Chicks without lenses were exposed daily (9 a.m. to 5 p.m.) for three days on two consecutive weeks to 2 Hz sinusoidally modulated illumination (mean illuminance of 680 lux) to one of the following: in-phase modulated luminance flicker (LUM), counterphase-modulated red/green (R/G Color) or blue/yellow flicker (B/Y Color), combined color and luminance flicker (Color + LUM), reduced amplitude luminance flicker (Low LUM), or no flicker. After the three-day exposure to flicker, chicks were kept in a brooder under normal diurnal lighting for four days. Changes in the ocular components were measured with ultrasound and with a Hartinger Coincidence Refractometer (aus Jena, Jena, East Germany. After the first three-day exposure, luminance flicker produced more hyperopic refractions (LUM: 2.27 D) than did color flicker (R/G Color: 0.09 D; B/Y Color: −0.25 D). Changes in refraction were mainly due to changes in eye length, with color flicker producing much greater changes in eye length than luminance flicker (R/G Color: 102 μm; B/Y Color: 98 μm; LUM: 66 μm). Our results support the hypothesis that the eye can differentiate between hyperopic and myopic defocus on the basis of the effects of change in luminance or color contrast. PMID:22715194
Inner Retinal Oxygen Extraction Fraction in Response to Light Flicker Stimulation in Humans
Felder, Anthony E.; Wanek, Justin; Blair, Norman P.; Shahidi, Mahnaz
2015-01-01
Purpose Light flicker has been shown to stimulate retinal neural activity, increase blood flow, and alter inner retinal oxygen metabolism (MO2) and delivery (DO2). The purpose of the study was to determine the change in MO2 relative to DO2 due to light flicker stimulation in humans, as assessed by the inner retinal oxygen extraction fraction (OEF). Methods An optical imaging system, based on a modified slit lamp biomicroscope, was developed for simultaneous measurements of retinal vascular diameter (D) and oxygen saturation (SO2). Retinal images were acquired in 20 healthy subjects before and during light flicker stimulation. Arterial and venous D (DA and DV) and SO2 (SO2A and SO2V) were quantified within a circumpapillary region. Oxygen extraction fraction was defined as the ratio of MO2 to DO2 and was calculated as (SO2A − SO2V)/SO2A. Reproducibility of measurements was assessed. Results Coefficients of variation and intraclass correlation coefficients of repeated measurements were <5% and ≥0.83, respectively. During light flicker stimulation, DA, DV , and SO2V significantly increased (P ≤ 0.004). Oxygen extraction fraction was 0.37 ± 0.08 before light flicker and significantly decreased to 0.31 ± 0.07 during light flicker (P = 0.001). Conclusions Oxygen extraction fraction before and during light flicker stimulation is reported in human subjects for the first time. Oxygen extraction fraction decreased during light flicker stimulation, indicating the change in DO2 exceeded that of MO2. This technology is potentially useful for the detection of changes in OEF response to light flicker in physiological and pathological retinal conditions. PMID:26469748
Huang, Kuo-Chen; Lin, Rung-Tai; Wu, Chih-Fu
2011-08-01
This study investigated the effects of number of strokes in Chinese characters, flicker rate, flicker type, and character/background color combination on search performance. 37 participants ages 14 to 18 years were randomly assigned to each flicker-type condition. The search field contained 36 characters arranged in a 6 x 6 matrix. Participants were asked to search for the target characters among the surrounding distractors and count how many target characters were displayed in the search array. Analysis indicated that the character/background color combination significantly affected search times. The color combinations of white/purple and white/green yielded search times greater than those for black/white and black/yellow combinations. A significant effect for flicker type on search time was also identified. Rotating characters facilitated search time, compared with twinkling ones. The number of strokes and the flicker rates also had positive effects on search performances. For flicker rate, the search accuracy for 0.5 Hz was greater than that for 1.0 Hz, and the latter was also greater than that for 2.0 Hz. Results are applicable to web advertisement designs containing dynamic characters, in terms of how to best capture readers' attention by various means of dynamic character presentation.
The impact of electrode materials on 1/f noise in piezoelectric AlN contour mode resonators
NASA Astrophysics Data System (ADS)
Kim, Hoe Joon; Jung, Soon In; Segovia-Fernandez, Jeronimo; Piazza, Gianluca
2018-05-01
This paper presents a detailed analysis on the impact of electrode materials and dimensions on flicker frequency (1/f) noise in piezoelectric aluminum nitride (AlN) contour mode resonators (CMRs). Flicker frequency noise is a fundamental noise mechanism present in any vibrating mechanical structure, whose sources are not generally well understood. 1 GHz AlN CMRs with three different top electrode materials (Al, Au, and Pt) along with various electrode lengths and widths are fabricated to control the overall damping acting on the device. Specifically, the use of different electrode materials allows control of thermoelastic damping (TED), which is the dominant damping mechanism for high frequency AlN CMRs and largely depends on the thermal properties (i.e. thermal diffusivities and expansion coefficients) of the metal electrode rather than the piezoelectric film. We have measured Q and 1/f noise of 68 resonators and the results show that 1/f noise decreases with increasing Q, with a power law dependence that is about 1/Q4. Interestingly, the noise level also depends on the type of electrode materials. Devices with Pt top electrode demonstrate the best noise performance. Our results help unveiling some of the sources of 1/f noise in these resonators, and indicate that a careful selection of the electrode material and dimensions could reduce 1/f noise not only in AlN-CMRs, but also in various classes of resonators, and thus enable ultra-low noise mechanical resonators for sensing and radio frequency applications.
NASA Astrophysics Data System (ADS)
Masi, Maria Gabriella; Peretto, Lorenzo; Rovati, Luigi; Ansari, Rafat R.
2010-02-01
Light flickering at a rate of 4- 20 cycles per second can produce unpleasant reactions such as nausea and vertigo. In this paper, the possibility of achieving an objective evaluation/prediction of the physiological effects induced by flicker is investigated using a new imaging method based on the pupil size determination. This method is also compared with the blood flow analysis in the choroid.
Kashif, Muhammad; Bonnety, Jérôme; Guibert, Philippe; Morin, Céline; Legros, Guillaume
2012-12-17
A Laser Extinction Method has been set up to provide two-dimensional soot volume fraction field time history at a tunable frequency up to 70 Hz inside an axis-symmetric diffusion flame experiencing slow unsteady phenomena preserving the symmetry. The use of a continuous wave laser as the light source enables this repetition rate, which is an incremental advance in the laser extinction technique. The technique is shown to allow a fine description of the soot volume fraction field in a flickering flame exhibiting a 12.6 Hz flickering phenomenon. Within this range of repetition rate, the technique and its subsequent post-processing require neither any method for time-domain reconstruction nor any correction for energy intrusion. Possibly complemented by such a reconstruction method, the technique should support further soot volume fraction database in oscillating flames that exhibit characteristic times relevant to the current efforts in the validation of soot processes modeling.
2014-09-01
rod moves about the illumination scene, the pixels in the detector start to flicker . The ‘ flickering ’ effect is due to the metal rod blocking THz...still possible to mitigate convective heat exchange between the sensor and the ambient surroundings. To mitigate the effects of convective heat...detector start to flicker . The ‘ flickering ’ effect is due to the metal rod blocking THz radiation. This effect is more apparent in the video
Training for Defense? From Stochastic Traits to Synchrony in Giant Honey Bees (Apis dorsata).
Weihmann, Frank; Hoetzl, Thomas; Kastberger, Gerald
2012-08-30
In Giant Honey Bees, abdomen flipping happens in a variety of contexts. It can be either synchronous or cascaded, such as in the collective defense traits of shimmering and rearing-up, or it can happen as single-agent behavior. Abdomen flipping is also involved in flickering behavior, which occurs regularly under quiescent colony state displaying singular or collective traits, with stochastic, and (semi-) synchronized properties. It presumably acts via visual, mechanoceptive, and pheromonal pathways and its goals are still unknown. This study questions whether flickering is preliminary to shimmering which is subject of the fs (flickering-shimmering)-transition hypothesis? We tested the respective prediction that trigger sites (ts) at the nest surface (where shimmering waves had been generated) show higher flickering activity than the alternative non-trigger sites (nts). We measured the flickering activity of ts- and nts-surface bees from two experimental nests, before and after the colony had been aroused by a dummy wasp. Arousal increased rate and intensity of the flickering activity of both ts- and nts cohorts (P < 0.05), whereby the flickering intensity of ts-bees were higher than that of nts-bees (P < 0.05). Under arousal, the colonies also increased the number of flickering-active ts- and nts-cohorts (P < 0.05). This provides evidence that cohorts which are specialist at launching shimmering waves are found across the quiescent nest zone. It also proves that arousal may reinforce the responsiveness of quiescent curtain bees for participating in shimmering, practically by recruiting additional trigger site bees for expanding repetition of rate and intensity of shimmering waves. This finding confirms the fs-transition hypothesis and constitutes evidence that flickering is part of a basal colony-intrinsic information system. Furthermore, the findings disprove that the muscle activity associated with flickering would heat up the surface bees. Hence, surface bees are not actively contributing to thermoregulation.
Training for Defense? From Stochastic Traits to Synchrony in Giant Honey Bees (Apis dorsata)
Weihmann, Frank; Hoetzl, Thomas; Kastberger, Gerald
2012-01-01
In Giant Honey Bees, abdomen flipping happens in a variety of contexts. It can be either synchronous or cascaded, such as in the collective defense traits of shimmering and rearing-up, or it can happen as single-agent behavior. Abdomen flipping is also involved in flickering behavior, which occurs regularly under quiescent colony state displaying singular or collective traits, with stochastic, and (semi-) synchronized properties. It presumably acts via visual, mechanoceptive, and pheromonal pathways and its goals are still unknown. This study questions whether flickering is preliminary to shimmering which is subject of the fs (flickering-shimmering)-transition hypothesis? We tested the respective prediction that trigger sites (ts) at the nest surface (where shimmering waves had been generated) show higher flickering activity than the alternative non-trigger sites (nts). We measured the flickering activity of ts- and nts-surface bees from two experimental nests, before and after the colony had been aroused by a dummy wasp. Arousal increased rate and intensity of the flickering activity of both ts- and nts cohorts (P < 0.05), whereby the flickering intensity of ts-bees were higher than that of nts-bees (P < 0.05). Under arousal, the colonies also increased the number of flickering-active ts- and nts-cohorts (P < 0.05). This provides evidence that cohorts which are specialist at launching shimmering waves are found across the quiescent nest zone. It also proves that arousal may reinforce the responsiveness of quiescent curtain bees for participating in shimmering, practically by recruiting additional trigger site bees for expanding repetition of rate and intensity of shimmering waves. This finding confirms the fs-transition hypothesis and constitutes evidence that flickering is part of a basal colony-intrinsic information system. Furthermore, the findings disprove that the muscle activity associated with flickering would heat up the surface bees. Hence, surface bees are not actively contributing to thermoregulation. PMID:26466631
[Flicker comparison of optic disc photographs: sensitivity and specificity].
Funk, Jens; Lagrèze, Wolf; Zeyen, Thierry
2002-12-01
Examination and documentation of the optic nerve head are essential in monitoring glaucoma patients. Even minor changes in optic nerve head morphology can be visualised using the so-called flicker test: Two optic nerve head photographs, taken at consecutive examinations, are superimposed by projection. When occluding the pictures in a rapid alternating fashion, changes in optic nerve head morphology appear as motion. In this study, we evaluated sensitivity and specificity of the flicker test. A set of 33 pairs of serial optic disc slides was used as gold standard. These 33 pairs had been classified earlier by 3 independent groups of experts. 23 had been classified as "no change over time", 10 had been classified as "change". All 33 pairs were now evaluated by flicker comparison in a masked fashion. Flicker comparison usually took 1 minute per pair of slides. Sensitivity was 90 %, specificity was 65 %. The sensitivity was reasonably high. The moderate specificity was due to some cases showing "change" with the flicker comparison which might have been overlooked by the expert groups. Flicker comparison is an easy, fast and reliable technique to evaluate pairs of consecutive optic disc photographs.
H1 antihistamines and driving.
Popescu, Florin Dan
2008-01-01
Driving performances depend on cognitive, psychomotor and perception functions. The CNS adverse effects of some H1 antihistamines can alter the patient ability to drive. Data from studies using standardized objective cognitive and psychomotor tests (Choice Reaction Time, Critical Flicker Fusion. Digital Symbol Substitution Test), functional brain imaging (Positron Emission Tomography, functional Magnetic Resonance Imaging), neurophysiological studies (Multiple Sleep Latency Test, auditory and visual evoked potentials), experimental simulated driving (driving simulators) and real driving studies (the Highway Driving Test, with the evaluation of the Standard Deviation Lateral Position, and the Car Following Test, with the measurement of the Brake Reaction Time) must be discussed in order to classify a H1 antihistamine as a true non-sedating one.
Florin-Dan, Popescu
2008-01-01
Driving performances depend on cognitive, psychomotor and perception functions. The CNS adverse effects of some H1 antihistamines can alter the patient ability to drive. Data from studies using standardized objective cognitive and psychomotor tests (Choice Reaction Time, Critical Flicker Fusion, Digital Symbol Substitution Test), functional brain imaging (Positron Emission Tomography, functional Magnetic Resonance Imaging), neurophysiological studies (Multiple Sleep Latency Test, auditory and visual evoked potentials), experimental simulated driving (driving simulators) and real driving studies (the Highway Driving Test, with the evaluation of the Standard Deviation Lateral Position, and the Car Following Test, with the measurement of the Brake Reaction Time) must be discussed in order to classify a H1 antihistamine as a true non-sedating one. PMID:20108503
Yamada, Shimpei; Miyake, Shinji
2007-03-01
This study examined the effects of long term mental arithmetic on physiological parameters, subjective indices and task performances to investigate the psychophysiological changes induced by mental tasks. Fifteen male university students performed six successive trials of a ten-minute mental arithmetic task. They took a five-minute resting period before and after the tasks. CFF (Critical Flicker Fusion frequency) and subjective fatigue scores using a visual analog scale, POMS (Profiles of Mood States) and SFF (Subjective Feelings of Fatigue) were obtained after each task and resting period. The voices of participants who were instructed to speak five Japanese vowels ('a', 'i', 'u', 'e', 'o') were recorded after each block to investigate a chaotic property of vocal signals that is reported to be changed by fatigue. Subjective workload ratings were also obtained by the NASA-TLX (National Aeronautics and Space Administration-Task Load Index) after the task. Physiological signals of ECG (Electrocardiogram), PTG (Photoelectric Plethysmogram), SCL (Skin Conductance Level), TBV (Tissue Blood Volume) and Respiration were recorded for all experimental blocks. The number of answers, correct rates and average levels of task difficulty for each ten-minute task were used as task performance indices. In this experiment, the task performance did not decrease, whereas subjective fatigue increased. Activation of the sympathetic nervous system was suggested by physiological parameters.
The visual ecology of a deep-sea fish, the escolar Lepidocybium flavobrunneum (Smith, 1843)†
Landgren, Eva; Fritsches, Kerstin; Brill, Richard; Warrant, Eric
2014-01-01
Escolar (Lepidocybium flavobrunneum, family Gempylidae) are large and darkly coloured deep-sea predatory fish found in the cold depths (more than 200 m) during the day and in warm surface waters at night. They have large eyes and an overall low density of retinal ganglion cells that endow them with a very high optical sensitivity. Escolar have banked retinae comprising six to eight layers of rods to increase the optical path length for maximal absorption of the incoming light. Their retinae possess two main areae of higher ganglion cell density, one in the ventral retina viewing the dorsal world above (with a moderate acuity of 4.6 cycles deg−1), and the second in the temporal retina viewing the frontal world ahead. Electrophysiological recordings of the flicker fusion frequency (FFF) in isolated retinas indicate that escolar have slow vision, with maximal FFF at the highest light levels and temperatures (around 9 Hz at 23°C) which fall to 1–2 Hz in dim light or cooler temperatures. Our results suggest that escolar are slowly moving sit-and-wait predators. In dim, warm surface waters at night, their slow vision, moderate dorsal resolution and highly sensitive eyes may allow them to surprise prey from below that are silhouetted in the downwelling light. PMID:24395966
The effects of moclobemide on autonomic and cognitive functions in healthy volunteers.
Siepmann, M; Handel, J; Mueck-Weymann, M; Kirch, W
2004-03-01
Moclobemide, a reversible and selective inhibitor of the MAO-A isoenzyme, is marketed as an antidepressant that lacks autonomic and cognitive side effects. However, only few and inconclusive quantitative data on the effects of moclobemide on autonomic and cognitive functions have been reported in the literature. Therefore, a double-blind, randomized, placebo-controlled crossover trial was performed. Twelve healthy male volunteers (age 22-29 years) received orally 150 mg moclobemide b.i.d. and placebo for 14 days each. Heart rate variability (HRV) and skin conductance response (SCR) following sudden deep breath were employed as parameters for autonomic function. Quantitative EEG (qEEG) and psychometric tests served as parameters for cognitive function. Measurements were performed before the start of drug administration and repeatedly on the last treatment day. Parameters of HRV and SCR were not changed by multiple dosing with moclobemide (P > 0.05). Neither cognitive functions such as flicker fusion frequency, memory, choice reaction time, and psychomotor performance nor qEEG was significantly influenced, but subjective tiredness was decreased at all time points of measurement after multiple dosing with moclobemide (P < 0.05). In conclusion, moclobemide does not appear to influence autonomic functions or cognitive functions when given subchronically to healthy humans. In contrast, changes in subjective mood hint at a subtle activating effect.
J8 | Force Structure, Resources & Assessment Contact Home : Contact Chairman's Social Media Chairman's Flicker Chairman's Blog SEAC's Social Media SEAC's Facebook SEAC's Flicker SEAC's Twitter Joint Staff's Social Media Joint Staff's Facebook Joint Staff's Flicker Joint Staff 's Twitter Social Media
Ritt, Martin; Harazny, Joanna M; Ott, Christian; Raff, Ulrike; Bauernschubert, Philipp; Lehmann, Marina; Michelson, Georg; Schmieder, Roland E
2012-09-01
We hypothesized that the increase of retinal capillary blood flow (RCF) to flicker light exposure is impaired in subjects with arterial hypertension. In 146 nondiabetic untreated male subjects with (n=50) or without (n=96) arterial hypertension, RCF was measured before and after flicker light exposure noninvasively and in vivo using scanning laser Doppler flowmetry. In addition, in a subgroup of 28 subjects, the change of RCF to flicker light exposure was again assessed during parallel infusion of nitric oxide synthase inhibitor N-monomethyl-L-arginine (L-NMMA). The increase of RCF to flicker light exposure was lower in patients with untreated hypertension compared with normotensive subjects when expressed in absolute terms (7.69±54 versus 27.2±44 AU; P adjusted=0.013) or percent changes (2.95±14 versus 8.33±12%; P adjusted=0.023). Systolic (β=-0.216; P=0.023) but not diastolic blood pressure (β=-0.117; P=0.243) or mean arterial pressure (β=-0.178; P=0.073) was negatively related to the percent change of RCF to flicker light exposure, independently of other cardiovascular risk factors. In the subgroup of 28 subjects, the increase of RCF to flicker light exposure was similar at baseline and during parallel infusion of L-NMMA when expressed in absolute terms (20.0±51 versus 22.6±56 AU; P=0.731) or percent changes (7.12±16 versus 8.29±18%; P=0.607). The increase of RCF to flicker light exposure is impaired in arterial hypertension. In the subgroup of the total study cohort, nitric oxide was not a major determinant of the increase of RCF to flicker light exposure.
Temporal flicker reduction and denoising in video using sparse directional transforms
NASA Astrophysics Data System (ADS)
Kanumuri, Sandeep; Guleryuz, Onur G.; Civanlar, M. Reha; Fujibayashi, Akira; Boon, Choong S.
2008-08-01
The bulk of the video content available today over the Internet and over mobile networks suffers from many imperfections caused during acquisition and transmission. In the case of user-generated content, which is typically produced with inexpensive equipment, these imperfections manifest in various ways through noise, temporal flicker and blurring, just to name a few. Imperfections caused by compression noise and temporal flicker are present in both studio-produced and user-generated video content transmitted at low bit-rates. In this paper, we introduce an algorithm designed to reduce temporal flicker and noise in video sequences. The algorithm takes advantage of the sparse nature of video signals in an appropriate transform domain that is chosen adaptively based on local signal statistics. When the signal corresponds to a sparse representation in this transform domain, flicker and noise, which are spread over the entire domain, can be reduced easily by enforcing sparsity. Our results show that the proposed algorithm reduces flicker and noise significantly and enables better presentation of compressed videos.
The stochastic nature of action potential backpropagation in apical tuft dendrites.
Short, Shaina M; Oikonomou, Katerina D; Zhou, Wen-Liang; Acker, Corey D; Popovic, Marko A; Zecevic, Dejan; Antic, Srdjan D
2017-08-01
In cortical pyramidal neurons, backpropagating action potentials (bAPs) supply Ca 2+ to synaptic contacts on dendrites. To determine whether the efficacy of AP backpropagation into apical tuft dendrites is stable over time, we performed dendritic Ca 2+ and voltage imaging in rat brain slices. We found that the amplitude of bAP-Ca 2+ in apical tuft branches was unstable, given that it varied from trial to trial (termed "bAP-Ca 2+ flickering"). Small perturbations in dendritic physiology, such as spontaneous synaptic inputs, channel inactivation, or temperature-induced changes in channel kinetics, can cause bAP flickering. In the tuft branches, the density of Na + and K + channels was sufficient to support local initiation of fast spikelets by glutamate iontophoresis. We quantified the time delay between the somatic AP burst and the peak of dendritic Ca 2+ transient in the apical tuft, because this delay is important for induction of spike-timing dependent plasticity. Depending on the frequency of the somatic AP triplets, Ca 2+ signals peaked in the apical tuft 20-50 ms after the 1st AP in the soma. Interestingly, at low frequency (<20 Hz), the Ca 2+ peaked sooner than at high frequency, because only the 1st AP invaded tuft. Activation of dendritic voltage-gated Ca 2+ channels is sensitive to the duration of the dendritic voltage transient. In apical tuft branches, small changes in the duration of bAP voltage waveforms cause disproportionately large increases in dendritic Ca 2+ influx (bAP-Ca 2+ flickering). The stochastic nature of bAP-Ca 2+ adds a new perspective on the mechanisms by which pyramidal neurons combine inputs arriving at different cortical layers. NEW & NOTEWORTHY The bAP-Ca 2+ signal amplitudes in some apical tuft branches randomly vary from moment to moment. In repetitive measurements, successful AP invasions are followed by complete failures. Passive spread of voltage from the apical trunk into the tuft occasionally reaches the threshold for local Na + spike, resulting in stronger Ca 2+ influx. During a burst of three somatic APs, the peak of dendritic Ca 2+ in the apical tuft occurs with a delay of 20-50 ms depending on AP frequency. Copyright © 2017 the American Physiological Society.
Zolpidem 10 mg given at daytime is not antagonized by 300 mg caffeine in man.
Mattila, M J; Nurminen, M L; Vainio, P; Vanakoski, J
1998-07-01
Caffeine counteracts various effects of traditional benzodiazepines (BZDs). As zolpidem, a short-acting hypnotic, is an atypical GABAA-BZD agonist, we investigated when caffeine would counteract the effects of zolpidem as well. In daytime study I, zolpidem 10 mg (capsule) and caffeine 150 or 300 mg (in decaffeinated coffee) were given, alone and in combinations, to parallel groups (n = 15-17) of healthy students in double-blind and placebo-controlled manner. Objective and subjective tests were done before and 45 min and 90 min after intake. Ranked delta values (changes from baseline) were analysed by one-way contrast ANOVA and Scheffe's tests. In daytime study II, four healthy subjects took zolpidem 10 mg alone, and together with blinded caffeine 250 mg or (at -45 min) erythromycin 750 mg. Objective and subjective effects were measured and plasma zolpidem concentrations assayed at baseline and 45 min and 90 min after zolpidem intake. In study I, practice effects after placebo (ad + 30%) were seen for letter cancellation and digit symbol substitution but not for flicker fusion tests. Zolpidem alone significantly impaired (P < 0.05 vs delta placebo) letter cancellation and digit symbol substitution at 45 min and 90 min, lowered the flicker fusion threshold at 45 min, and caused subjective drowsiness, mental slowness, clumsiness and feeling of poor performance. Caffeine alone showed a non-significant trend to improve objective performance. The combined effects of zolpidem and either dose of caffeine matched those measured after zolpidem alone. Zolpidem + caffeine 300 mg was not stronger than zolpidem + caffeine 150 mg in impairing immediate memory and causing subjective sedation. In study II, zolpidem caused objective and subjective sedation; neither caffeine nor erythromycin modulated the effects of zolpidem or plasma zolpidem concentrations. The sedative effects of 10 mg of zolpidem are not antagonized by 150-300 mg of caffeine in pharmacodynamic or pharmacokinetic terms.
Swanson, William H; Dul, Mitchell W; Horner, Douglas G; Liu, Tiffany; Tran, Irene
2014-01-20
To develop perimetric stimuli for which sensitivities are more resistant to reduced retinal illumination than current clinical perimeters. Fifty-four people free of eye disease were dilated and tested monocularly. For each test, retinal illumination was attenuated with neutral density (ND) filters, and a standard adaptation model was fit to derive mean and SEM for the adaptation parameter (NDhalf). For different stimuli, t-tests on NDhalf were used to assess significance of differences in consistency with Weber's law. Three experiments used custom Gaussian-windowed contrast sensitivity perimetry (CSP). Experiment 1 used CSP-1, with a Gaussian temporal pulse, a spatial frequency of 0.375 cyc/deg (cpd), and SD of 1.5°. Experiment 1 also used the Humphrey Matrix perimeter, with the N-30 test using 0.25 cpd and 25 Hz flicker. Experiment 2 used a rectangular temporal pulse, SDs of 0.25° and 0.5°, and spatial frequencies of 0.0 and 1.0 cpd. Experiment 3 used CSP-2, with 5-Hz flicker, SDs from 0.5° to 1.8°, and spatial frequencies from 0.14 to 0.50 cpd. In Experiment 1, CSP-1 was more consistent with Weber's law (NDhalf ± SEM = 1.86 ± 0.08 log unit) than N-30 (NDhalf = 1.03 ± 0.03 log unit; t > 9, P < 0.0001). All stimuli used in Experiments 2 and 3 had comparable consistency with Weber's law (NDhalf = 1.49-1.69 log unit; t < 2). Perimetric sensitivities were consistent with Weber's law when higher temporal frequencies were avoided.
Goetz, Georges; Smith, Richard; Lei, Xin; Galambos, Ludwig; Kamins, Theodore; Mathieson, Keith; Sher, Alexander; Palanker, Daniel
2015-01-01
Purpose To evaluate the contrast sensitivity of a degenerate retina stimulated by a photovoltaic subretinal prosthesis, and assess the impact of low contrast sensitivity on transmission of visual information. Methods We measure ex vivo the full-field contrast sensitivity of healthy rat retina stimulated with white light, and the contrast sensitivity of degenerate rat retina stimulated with a subretinal prosthesis at frequencies exceeding flicker fusion (>20 Hz). Effects of eye movements on retinal ganglion cell (RGC) activity are simulated using a linear–nonlinear model of the retina. Results Retinal ganglion cells adapt to high frequency stimulation of constant intensity, and respond transiently to changes in illumination of the implant, exhibiting responses to ON-sets, OFF-sets, and both ON- and OFF-sets of light. The percentage of cells with an OFF response decreases with progression of the degeneration, indicating that OFF responses are likely mediated by photoreceptors. Prosthetic vision exhibits reduced contrast sensitivity and dynamic range, with 65% contrast changes required to elicit responses, as compared to the 3% (OFF) to 7% (ON) changes with visible light. The maximum number of action potentials elicited with prosthetic stimulation is at most half of its natural counterpart for the ON pathway. Our model predicts that for most visual scenes, contrast sensitivity of prosthetic vision is insufficient for triggering RGC activity by fixational eye movements. Conclusions Contrast sensitivity of prosthetic vision is 10 times lower than normal, and dynamic range is two times below natural. Low contrast sensitivity and lack of OFF responses hamper delivery of visual information via a subretinal prosthesis. PMID:26540657
Flicker Adaptation of Low-Level Cortical Visual Neurons Contributes to Temporal Dilation
ERIC Educational Resources Information Center
Ortega, Laura; Guzman-Martinez, Emmanuel; Grabowecky, Marcia; Suzuki, Satoru
2012-01-01
Several seconds of adaptation to a flickered stimulus causes a subsequent brief static stimulus to appear longer in duration. Nonsensory factors, such as increased arousal and attention, have been thought to mediate this flicker-based temporal-dilation aftereffect. In this study, we provide evidence that adaptation of low-level cortical visual…
A noninvasive brain computer interface using visually-induced near-infrared spectroscopy responses.
Chen, Cheng-Hsuan; Ho, Ming-Shan; Shyu, Kuo-Kai; Hsu, Kou-Cheng; Wang, Kuo-Wei; Lee, Po-Lei
2014-09-19
Visually-induced near-infrared spectroscopy (NIRS) response was utilized to design a brain computer interface (BCI) system. Four circular checkerboards driven by distinct flickering sequences were displayed on a LCD screen as visual stimuli to induce subjects' NIRS responses. Each flickering sequence was a concatenated sequence of alternative flickering segments and resting segments. The flickering segment was designed with fixed duration of 3s whereas the resting segment was chosen randomly within 15-20s to create the mutual independencies among different flickering sequences. Six subjects were recruited in this study and subjects were requested to gaze at the four visual stimuli one-after-one in a random order. Since visual responses in human brain are time-locked to the onsets of visual stimuli and the flicker sequences of distinct visual stimuli were designed mutually independent, the NIRS responses induced by user's gazed targets can be discerned from non-gazed targets by applying a simple averaging process. The accuracies for the six subjects were higher than 90% after 10 or more epochs being averaged. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Takano, Kouji; Komatsu, Tomoaki; Hata, Naoki; Nakajima, Yasoichi; Kansaku, Kenji
2009-08-01
The white/gray flicker matrix has been used as a visual stimulus for the so-called P300 brain-computer interface (BCI), but the white/gray flash stimuli might induce discomfort. In this study, we investigated the effectiveness of green/blue flicker matrices as visual stimuli. Ten able-bodied, non-trained subjects performed Alphabet Spelling (Japanese Alphabet: Hiragana) using an 8 x 10 matrix with three types of intensification/rest flicker combinations (L, luminance; C, chromatic; LC, luminance and chromatic); both online and offline performances were evaluated. The accuracy rate under the online LC condition was 80.6%. Offline analysis showed that the LC condition was associated with significantly higher accuracy than was the L or C condition (Tukey-Kramer, p < 0.05). No significant difference was observed between L and C conditions. The LC condition, which used the green/blue flicker matrix was associated with better performances in the P300 BCI. The green/blue chromatic flicker matrix can be an efficient tool for practical BCI application.
Wearden, J H; Williams, Emily A; Jones, Luke A
2017-03-01
Four experiments investigated the effect of pre-stimulus events on judgements of the subjective duration of tones that they preceded. Experiments 1 to 4 used click trains, flickering squares, expanding circles, and white noise as pre-stimulus events and showed that (a) periodic clicks appeared to "speed up" the pacemaker of an internal clock but that the effect wore off over a click-free delay, (b) aperiodic click trains, and visual stimuli in the form of flickering squares and expanding circles, also produced similar increases in estimated tone duration, as did white noise, although its effect was weaker. A fifth experiment examined the effects of periodic flicker on reaction time and showed that, as with periodic clicks in a previous experiment, reaction times were shorter when preceded by flicker than without.
Nanoscale MOS devices: device parameter fluctuations and low-frequency noise (Invited Paper)
NASA Astrophysics Data System (ADS)
Wong, Hei; Iwai, Hiroshi; Liou, J. J.
2005-05-01
It is well-known in conventional MOS transistors that the low-frequency noise or flicker noise is mainly contributed by the trapping-detrapping events in the gate oxide and the mobility fluctuation in the surface channel. In nanoscale MOS transistors, the number of trapping-detrapping events becomes less important because of the large direct tunneling current through the ultrathin gate dielectric which reduces the probability of trapping-detrapping and the level of leakage current fluctuation. Other noise sources become more significant in nanoscale devices. The source and drain resistance noises have greater impact on the drain current noise. Significant contribution of the parasitic bipolar transistor noise in ultra-short channel and channel mobility fluctuation to the channel noise are observed. The channel mobility fluctuation in nanoscale devices could be due to the local composition fluctuation of the gate dielectric material which gives rise to the permittivity fluctuation along the channel and results in gigantic channel potential fluctuation. On the other hand, the statistical variations of the device parameters across the wafer would cause the noise measurements less accurate which will be a challenge for the applicability of analytical flicker noise model as a process or device evaluation tool for nanoscale devices. Some measures for circumventing these difficulties are proposed.
Stiles—Crawford effect and the bleaching of cone pigments
Coble, J. R.; Rushton, W. A. H.
1971-01-01
1. The efficiency of light entering the eye through various points in the pupil (Stiles—Crawford effect) was studied using two criteria: (a) visual brightness judged by flicker fusion and (b) the rate of cone pigment bleaching measured by reflexion densitometry. 2. Both measurements were made in the same apparatus with the same geometry of presentation and both gave the same Stiles—Crawford effect. 3. This suggests that the densitometer measures pigment deep in the outer segments of the cones where light is absorbed for vision. 4. Foveal cones seem all to point in the same direction, since the fraction of pigment bleached by light entering the pupil at any one point is the same when measured by light entering anywhere. PMID:5571926
Analysis of the Flicker Level Produced by a Fixed-Speed Wind Turbine
NASA Astrophysics Data System (ADS)
Suppioni, Vinicius; P. Grilo, Ahda
2013-10-01
In this article, the analysis of the flicker emission during continuous operation of a mid-scale fixed-speed wind turbine connected to a distribution system is presented. Flicker emission is investigated based on simulation results, and the dependence of flicker emission on short-circuit capacity, grid impedance angle, mean wind speed, and wind turbulence is analyzed. The simulations were conducted in different programs in order to provide a more realistic wind emulation and detailed model of mechanical and electrical components of the wind turbine. Such aim is accomplished by using FAST (Fatigue, Aerodynamics, Structures, and Turbulence) to simulate the mechanical parts of the wind turbine, Simulink/MatLab to simulate the electrical system, and TurbSim to obtain the wind model. The results show that, even for a small wind generator, the flicker level can limit the wind power capacity installed in a distribution system.
Meteoroid rotation and fireball flickering: a case study of the Innisfree fireball
NASA Astrophysics Data System (ADS)
Beech, Martin
2001-09-01
Some 5 per cent of bright meteors show rapid, quasi-periodic brightness variations. It is argued that this effect, observationally known as flickering, is a manifestation of the rotational modulation of surface mass loss through ablation of a non-spherical meteoroid. We develop a set of time-dependent, single-body ablation equations that include the effect of cross-section area modulation. We present a discussion of the effects that the rotation of a non-spherical meteoroid has on the resultant meteor light curve, and we look in depth at the data related to the fireball associated with the fall of the Innisfree meteorite. We find that the parent object to the Innisfree meteorite was spinning at a rotation frequency of 2.5Hz when it encountered the Earth's upper atmosphere. We also find that the Innisfree parent body had an initial mass of about 20kg and that the ratio of its semiminor and semimajor axes was about 0.5.
Application of a single-flicker online SSVEP BCI for spatial navigation.
Chen, Jingjing; Zhang, Dan; Engel, Andreas K; Gong, Qin; Maye, Alexander
2017-01-01
A promising approach for brain-computer interfaces (BCIs) employs the steady-state visual evoked potential (SSVEP) for extracting control information. Main advantages of these SSVEP BCIs are a simple and low-cost setup, little effort to adjust the system parameters to the user and comparatively high information transfer rates (ITR). However, traditional frequency-coded SSVEP BCIs require the user to gaze directly at the selected flicker stimulus, which is liable to cause fatigue or even photic epileptic seizures. The spatially coded SSVEP BCI we present in this article addresses this issue. It uses a single flicker stimulus that appears always in the extrafoveal field of view, yet it allows the user to control four control channels. We demonstrate the embedding of this novel SSVEP stimulation paradigm in the user interface of an online BCI for navigating a 2-dimensional computer game. Offline analysis of the training data reveals an average classification accuracy of 96.9±1.64%, corresponding to an information transfer rate of 30.1±1.8 bits/min. In online mode, the average classification accuracy reached 87.9±11.4%, which resulted in an ITR of 23.8±6.75 bits/min. We did not observe a strong relation between a subject's offline and online performance. Analysis of the online performance over time shows that users can reliably control the new BCI paradigm with stable performance over at least 30 minutes of continuous operation.
Abell, Robin G; Hewitt, Alex W; Andric, Marko; Allen, Penelope L; Verma, Nitin
2014-03-01
To establish the normal macular pigment density (MPOD) in a healthy adult Australian sample using heterochromatic flicker photometry (HFP). Macular pigment density was measured using heterochromatic flicker photometry in a total of 201 subjects ranging in age from 21 to 84 years with healthy macula. Fifty-seven of the healthy subjects also completed a food-frequency dietary questionnaire. Best-corrected visual acuity (BCVA) was measured using logMAR, chart and macular morphological profiles were assessed using high-resolution integrated Fourier-domain optical coherence tomography (OCT). The average MPOD value was 0.41 ± 0.20 (range 0.07-0.79). There was no statistically significant difference between values in the left and right eye, with good interocular agreement (0.41 vs 0.40, r = 0.893, p < 0.01). Age significantly predicted MPOD score (R (2) = 0.07, p < 0.05). A subgroup analysis of patients who completed the dietary questionnaire revealed a close correlation between higher diet scores and higher MPOD (r = 0.720 p = 0.031). There was no effect of smoking, gender, or iris colour on MPOD values. There was no significant correlation between BCVA, macular OCT profiles, and MPOD. Given that MPOD values are potentially affected by geographical variation, we have determined a mean MPOD value for healthy subjects in a population south of the equator, providing a reference point for future studies on Caucasian samples.
Macular pigment optical density measured by heterochromatic modulation photometry.
Huchzermeyer, Cord; Schlomberg, Juliane; Welge-Lüssen, Ulrich; Berendschot, Tos T J M; Pokorny, Joel; Kremers, Jan
2014-01-01
To psychophysically determine macular pigment optical density (MPOD) employing the heterochromatic modulation photometry (HMP) paradigm by estimating 460 nm absorption at central and peripheral retinal locations. For the HMP measurements, two lights (B: 460 nm and R: 660 nm) were presented in a test field and were modulated in counterphase at medium or high frequencies. The contrasts of the two lights were varied in tandem to determine flicker detection thresholds. Detection thresholds were measured for different R:B modulation ratios. The modulation ratio with minimal sensitivity (maximal threshold) is the point of equiluminance. Measurements were performed in 25 normal subjects (11 male, 14 female; age: 30 ± 11 years, mean ± sd) using an eight channel LED stimulator with Maxwellian view optics. The results were compared with those from two published techniques - one based on heterochromatic flicker photometry (Macular Densitometer) and the other on fundus reflectometry (MPR). We were able to estimate MPOD with HMP using a modified theoretical model that was fitted to the HMP data. The resultant MPODHMP values correlated significantly with the MPODMPR values and with the MPODHFP values obtained at 0.25° and 0.5° retinal eccentricity. HMP is a flicker-based method with measurements taken at a constant mean chromaticity and luminance. The data can be well fit by a model that allows all data points to contribute to the photometric equality estimate. Therefore, we think that HMP may be a useful method for MPOD measurements, in basic and clinical vision experiments.
Swanson, William H.; Dul, Mitchell W.; Horner, Douglas G.; Liu, Tiffany; Tran, Irene
2014-01-01
Purpose. To develop perimetric stimuli for which sensitivities are more resistant to reduced retinal illumination than current clinical perimeters. Methods. Fifty-four people free of eye disease were dilated and tested monocularly. For each test, retinal illumination was attenuated with neutral density (ND) filters, and a standard adaptation model was fit to derive mean and SEM for the adaptation parameter (NDhalf). For different stimuli, t-tests on NDhalf were used to assess significance of differences in consistency with Weber's law. Three experiments used custom Gaussian-windowed contrast sensitivity perimetry (CSP). Experiment 1 used CSP-1, with a Gaussian temporal pulse, a spatial frequency of 0.375 cyc/deg (cpd), and SD of 1.5°. Experiment 1 also used the Humphrey Matrix perimeter, with the N-30 test using 0.25 cpd and 25 Hz flicker. Experiment 2 used a rectangular temporal pulse, SDs of 0.25° and 0.5°, and spatial frequencies of 0.0 and 1.0 cpd. Experiment 3 used CSP-2, with 5-Hz flicker, SDs from 0.5° to 1.8°, and spatial frequencies from 0.14 to 0.50 cpd. Results. In Experiment 1, CSP-1 was more consistent with Weber's law (NDhalf ± SEM = 1.86 ± 0.08 log unit) than N-30 (NDhalf = 1.03 ± 0.03 log unit; t > 9, P < 0.0001). All stimuli used in Experiments 2 and 3 had comparable consistency with Weber's law (NDhalf = 1.49–1.69 log unit; t < 2). Conclusions. Perimetric sensitivities were consistent with Weber's law when higher temporal frequencies were avoided. PMID:24370832
High-order synchronization of hair cell bundles
NASA Astrophysics Data System (ADS)
Levy, Michael; Molzon, Adrian; Lee, Jae-Hyun; Kim, Ji-Wook; Cheon, Jinwoo; Bozovic, Dolores
2016-12-01
Auditory and vestibular hair cell bundles exhibit active mechanical oscillations at natural frequencies that are typically lower than the detection range of the corresponding end organs. We explore how these noisy nonlinear oscillators mode-lock to frequencies higher than their internal clocks. A nanomagnetic technique is used to stimulate the bundles without an imposed mechanical load. The evoked response shows regimes of high-order mode-locking. Exploring a broad range of stimulus frequencies and intensities, we observe regions of high-order synchronization, analogous to Arnold Tongues in dynamical systems literature. Significant areas of overlap occur between synchronization regimes, with the bundle intermittently flickering between different winding numbers. We demonstrate how an ensemble of these noisy spontaneous oscillators could be entrained to efficiently detect signals significantly above the characteristic frequencies of the individual cells.
High-order synchronization of hair cell bundles
Levy, Michael; Molzon, Adrian; Lee, Jae-Hyun; Kim, Ji-wook; Cheon, Jinwoo; Bozovic, Dolores
2016-01-01
Auditory and vestibular hair cell bundles exhibit active mechanical oscillations at natural frequencies that are typically lower than the detection range of the corresponding end organs. We explore how these noisy nonlinear oscillators mode-lock to frequencies higher than their internal clocks. A nanomagnetic technique is used to stimulate the bundles without an imposed mechanical load. The evoked response shows regimes of high-order mode-locking. Exploring a broad range of stimulus frequencies and intensities, we observe regions of high-order synchronization, analogous to Arnold Tongues in dynamical systems literature. Significant areas of overlap occur between synchronization regimes, with the bundle intermittently flickering between different winding numbers. We demonstrate how an ensemble of these noisy spontaneous oscillators could be entrained to efficiently detect signals significantly above the characteristic frequencies of the individual cells. PMID:27974743
Why do aged fluorescent tubes flicker?
NASA Astrophysics Data System (ADS)
Plihon, Nicolas; Ferrand, Jérémy; Guyomar, Tristan; Museur, Flavien; Taberlet, Nicolas
2017-11-01
Our everyday experience of aged and defective fluorescent tubes or bulbs informs us that they may flicker and emit a clicking sound while struggling to light up. In this article, the physical mechanisms controlling the initial illumination of a functioning fluorescent tube are investigated using a simple and affordable experimental setup. Thermionic emission from the electrodes of the tube controls the startup of fluorescent tubes. The origin of the faulty startup of aged fluorescent tubes is discussed and flickering regimes using functional tubes are artificially produced using a dedicated setup that decreases electron emission by the thermionic effect in a controlled manner. The physical parameters controlling the occurrence of flickering light are discussed, and their temporal statistics are reported.
Analysis and modeling of flicker noise in lateral asymmetric channel MOSFETs
NASA Astrophysics Data System (ADS)
Agarwal, Harshit; Kushwaha, Pragya; Gupta, Chetan; Khandelwal, Sourabh; Hu, Chenming; Chauhan, Yogesh Singh
2016-01-01
In this paper, flicker noise behavior of lateral non-uniformly doped MOSFET is studied using impedance field method. Our study shows that Klaassen Prins (KP) method, which forms the basis of noise model in MOSFETs, underestimates flicker noise in such devices. The same KP method overestimates thermal noise by 2-3 orders of magnitude in similar devices as demonstrated in Roy et al. (2007). This apparent discrepancy between thermal and flicker noise behavior lies in origin of these noises, which leads to opposite trend of local noise power spectral density vs doping. We have modeled the physics behind such behavior, which also explain the trends observed in the measurements (Agarwal et al., 2015).
Saletu, Michael; Anderer, Peter; Saletu-Zyhlarz, Gerda Maria; Mandl, Magdalena; Zeitlhofer, Josef; Saletu, Bernd
2008-08-01
Event-related potentials (ERPs) are sensitive measures of both perceptual and cognitive processes. The aim of the present study was to identify brain regions involved in the processes of cognitive dysfunction in narcolepsy by means of ERP tomography. In 17 drug-free patients with narcolepsy and 17 controls, ERPs were recorded (auditory odd-ball paradigm). Latencies, amplitudes and LORETA sources were determined for standard (N1 and P2) and target (N2 and P300) ERP components. Psychometry included measures of mental performance, affect and critical flicker fusion frequency (CFF). In the ERPs patients demonstrated delayed cognitive N2 and P300 components and reduced amplitudes in midline regions, while N1 and P2 components did not differ from controls. LORETA suggested reduced P300 sources bilaterally in the precuneus, the anterior and posterior cingulate gyri, the ventrolateral prefrontal cortex and the parahippocampal gyrus. In psychometry, patients demonstrated deteriorated mood, increased trait anxiety, decreased CFF and a trend toward reduced general verbal memory and psychomotor activity. Narcoleptic patients showed prolonged information processing, as indexed by N2 and P300 latencies and decreased energetic resources for cognitive processing. Electrophysiological aberrations in brain areas related to the 'executive attention network' and the 'limbic system' may contribute to a deterioration in mental performance and mood at the behavioral level.
Comparative visual ecophysiology of mid-Atlantic temperate reef fishes
Horodysky, Andrij Z.; Brill, Richard W.; Crawford, Kendyl C.; Seagroves, Elizabeth S.; Johnson, Andrea K.
2013-01-01
Summary The absolute light sensitivities, temporal properties, and spectral sensitivities of the visual systems of three mid-Atlantic temperate reef fishes (Atlantic spadefish [Ephippidae: Chaetodipterus faber], tautog [Labridae: Tautoga onitis], and black sea bass [Serranidae: Centropristis striata]) were studied via electroretinography (ERG). Pelagic Atlantic spadefish exhibited higher temporal resolution but a narrower dynamic range than the two more demersal foragers. The higher luminous sensitivities of tautog and black sea bass were similar to other benthic and demersal coastal mid-Atlantic fishes. Flicker fusion frequency experiments revealed significant interspecific differences at maximum intensities that correlated with lifestyle and habitat. Spectral responses of the three species spanned 400–610 nm, with high likelihood of cone dichromacy providing the basis for color and contrast discrimination. Significant day-night differences in spectral responses were evident in spadefish and black sea bass but not tautog, a labrid with characteristic structure-associated nocturnal torpor. Atlantic spadefish responded to a wider range of wavelengths than did deeper-dwelling tautog or black sea bass. Collectively, these results suggest that temperate reef-associated fishes are well-adapted to their gradient of brighter to dimmer photoclimates, representative of their unique ecologies and life histories. Continuing anthropogenic degradation of water quality in coastal environments, at a pace faster than the evolution of visual systems, may however impede visual foraging and reproductive signaling in temperate reef fishes. PMID:24285711
Lorach, Henri; Goetz, Georges; Mandel, Yossi; Lei, Xin; Kamins, Theodore I.; Mathieson, Keith; Huie, Philip; Dalal, Roopa; Harris, James S.; Palanker, Daniel
2014-01-01
Summary Loss of photoreceptors during retinal degeneration leads to blindness, but information can be reintroduced into the visual system using electrical stimulation of the remaining retinal neurons. Subretinal photovoltaic arrays convert pulsed illumination into pulsed electric current to stimulate the inner retinal neurons. Since required irradiance exceeds the natural luminance levels, an invisible near-infrared (915nm) light is used to avoid photophobic effects. We characterized the thresholds and dynamic range of cortical responses to prosthetic stimulation with arrays of various pixel sizes and with different number of photodiodes. Stimulation thresholds for devices with 140µm pixels were approximately half those of 70µm pixels, and with both pixel sizes, thresholds were lower with 2 diodes than with 3 diodes per pixel. In all cases these thresholds were more than two orders of magnitude below the ocular safety limit. At high stimulation frequencies (>20Hz), the cortical response exhibited flicker fusion. Over one order of magnitude of dynamic range could be achieved by varying either pulse duration or irradiance. However, contrast sensitivity was very limited. Cortical responses could be detected even with only a few illuminated pixels. Finally, we demonstrate that recording of the corneal electric potential in response to patterned illumination of the subretinal arrays allows monitoring the current produced by each pixel, and thereby assessing the changes in the implant performance over time. PMID:25255990
Saccadic eye movements as a measure of residual effects: temazepam compared with other hypnotics.
Hofferberth, B; Hirschberg; Grotemeyer
1986-01-01
Eye movements are classified into two categories: quickly running saccades and smooth pursuit movements. Saccades are fast conjugate eye movements with a preprogrammed direction, amplitude, and speed course; their purpose is to register new objects in the visual field. The duration and velocity of saccadic eye movements are very much dependent on vigilance. Comparisons were made with a number of psychometric tests [d 2 Durchstreichtest (cross out test), Viennese determination apparatus, and flicker fusion frequency] and the velocity of fast eye movements. The results of three separate investigations are presented. Standardization was undertaken in 100 healthy volunteers, 50 male and 50 female subjects aged between 20 and more than 50 years were included. In an open parallel group study, comparisons were made between various hypnotics with different half-lives (temazepam, flunitrazepam, flurazepam, and phenobarbital). There were 10 healthy volunteers in each group, and medication was taken as a single night-time dose for 7 nights. In a double-blind study, temazepam (20 mg/day) was tested against flunitrazepam (2 mg/day). Dosing lasted 7 days. A marked impairment of the saccadic eye movements was observed with flunitrazepam but not with temazepam. Of all the benzodiazepines tested, only temazepam had no influence on the parameters of the saccade test. These results can be explained by temazepam's short half-life and also by the fact that no active metabolites are formed.
Flicker-induced retinal arteriole dilation is reduced by ambient lighting.
Noonan, Jonathan E; Dusting, Gregory J; Nguyen, Thanh T; Man, Ryan E K; Best, William J; Lamoureux, Ecosse L
2014-08-07
To investigate the impact of ambient room lighting on the magnitude of flicker light-induced retinal vasodilations in healthy individuals. Twenty healthy nonsmokers participated in a balanced 2 × 2 crossover study. Retinal vascular imaging was performed with the dynamic vessel analyzer under reduced or normal ambient lighting, then again after 20 minutes under the alternate condition. Baseline calibers of selected arteriole and venule segments were recorded in measurement units. Maximum percentage dilations from baseline during 20 seconds of luminance flicker were calculated from the mean of three measurement cycles. Within-subject differences were assessed by repeated measures analysis of variance with the assumption of no carryover effects and pairwise comparisons from the fitted model. Mean (SD) maximum arteriole dilations during flicker stimulation under reduced and normal ambient lighting were 4.8% (2.3%) and 4.1% (1.9%), respectively (P = 0.019). Maximum arteriole dilations were (mean ± 95% confidence interval) 0.7% ± 0.6% lower under normal ambient lighting compared with reduced lighting. Ambient lighting had no significant effect on maximum venular dilations during flicker stimulation or on the baseline calibers of arterioles or venules. Retinal arteriole dilation in response to luminance flicker stimulation is reduced under higher ambient lighting conditions. Reduced responses with higher ambient lighting may reflect reduced contrast between the ON and OFF flicker phases. Although it may not always be feasible to conduct studies under reduced lighting conditions, ambient lighting levels should be consistent to ensure that comparisons are valid. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Tan, Bingyao; Mason, Erik; MacLellan, Benjamin; Bizheva, Kostadinka K
2017-03-01
To correlate visually evoked functional and blood flow changes in the rat retina measured simultaneously with a combined optical coherence tomography and electroretinography system (OCT+ERG). Male Brown Norway (n = 6) rats were dark adapted and anesthetized with ketamine/xylazine. Visually evoked changes in the retinal blood flow (RBF) and functional response were measured simultaneously with an OCT+ERG system with 3-μm axial resolution in retinal tissue and 47-kHz image acquisition rate. Both single flash (10 and 200 ms) and flicker (10 Hz, 20% duty cycle, 1- and 2-second duration) stimuli were projected onto the retina with a custom visual stimulator, integrated into the OCT imaging probe. Total axial RBF was calculated from circular Doppler OCT scans by integrating over the arterial and venal flow. Temporary increase in the RBF was observed with the 10- and 200-ms continuous stimuli (∼1% and ∼4% maximum RBF change, respectively) and the 10-Hz flicker stimuli (∼8% for 1-second duration and ∼10% for 2-second duration). Doubling the flicker stimulus duration resulted in ∼25% increase in the RBF peak magnitude with no significant change in the peak latency. Single flash (200 ms) and flicker (10 Hz, 1 second) stimuli of the same illumination intensity and photon flux resulted in ∼2× larger peak RBF magnitude and ∼25% larger RBF peak latency for the flicker stimulus. Short, single flash and flicker stimuli evoked measureable RBF changes with larger RBF magnitude and peak latency observed for the flicker stimuli.
Lei, Bo
2012-01-01
The rodent retina does not exhibit a positive OFF-response in the electroretinogram (ERG), which makes it difficult to evaluate its OFF-pathway functions in vivo. We studied the rod-driven OFF pathway responses by using a dark-adapted 10-Hz flicker ERG procedure in mouse. Conventional ERGs and 10-Hz dark-adapted flicker ERGs were obtained in wild-type mice (C57BL/6), in mice with pure rod (cpfl1) or pure cone (rho(-/-)) function, and in nob1 mice which have a selective ON-pathway defect. To isolate the response from ON or OFF pathway, glutamate analogs 2-amino-4-phosphobutyric acid (APB, an ON pathway blocker) and cis-2, 3-piperidine-dicarboxylic acid (PDA, an OFF pathway blocker), were injected intravitreally. The amplitude-intensity profile of the dark-adapted 10-Hz flicker ERG in the wild-type mice exhibits two peaks at middle and high light intensities. The two peaks represent rod- and cone-driven responses respectively. In APB-treated C57BL/6 mice and in nob1 mice, the dark-adapted ERG b-waves were absent. However, both rod- and cone-driven OFF pathway responses were evident with flicker ERG recording. At middle light intensities that activate only rod system, the flicker ERG responses in saline-injected nob1 mice were similar to those in APB-injected cpfl1 mice and wild-type mice. These responses are sensitive to PDA. The amplitudes of these rod-driven OFF pathway responses were approximately 20% of the total rod-driven flicker ERG responses. We demonstrate that the rod-OFF bipolar cell pathway is functional in the outer retina. The dark-adapted flicker ERG is practical for the evaluation of rod- and cone-driven responses, and the residual OFF pathway signals in subjects with ON pathway defects.
Synchronization of EEG activity in patients with bipolar disorder
NASA Astrophysics Data System (ADS)
Panischev, O. Yu; Demin, S. A.; Muhametshin, I. G.; Demina, N. Yu
2015-12-01
In paper we apply the method based on the Flicker-Noise Spectroscopy (FNS) to determine the differences in frequency-phase synchronization of the cortical electroencephalographic (EEG) activities in patients with bipolar disorder (BD). We found that for healthy subjects the frequency-phase synchronization of EEGs from long-range electrodes was significantly better for BD patients. In BD patients a high synchronization of EEGs was observed only for short-range electrodes. Thus, the FNS is a simple graphical method for qualitative analysis can be applied to identify the synchronization effects in EEG activity and, probably, may be used for the diagnosis of this syndrome.
Psychophysiological tests and provocation of subjects with mobile phone related symptoms.
Wilén, Jonna; Johansson, Amanda; Kalezic, Nebojsa; Lyskov, Eugene; Sandström, Monica
2006-04-01
The aim of the present study was to investigate the effect of exposure to a mobile phone-like radiofrequency (RF) electromagnetic field on persons experiencing subjective symptoms when using mobile phones (MP). Twenty subjects with MP-related symptoms were recruited and matched with 20 controls without MP-related symptoms. Each subject participated in two experimental sessions, one with true exposure and one with sham exposure, in random order. In the true exposure condition, the test subjects were exposed for 30 min to an RF field generating a maximum SAR(1g) in the head of 1 W/kg through an indoor base station antenna attached to a 900 MHz GSM MP. The following physiological and cognitive parameters were measured during the experiment: heart rate and heart rate variability (HRV), respiration, local blood flow, electrodermal activity, critical flicker fusion threshold (CFFT), short-term memory, and reaction time. No significant differences related to RF exposure conditions were detected. Also no differences in baseline data were found between subject groups, except for the reaction time, which was significantly longer among the cases than among the controls the first time the test was performed. This difference disappeared when the test was repeated. However, the cases differed significantly from the controls with respect to HRV as measured in the frequency domain. The cases displayed a shift in low/high frequency ratio towards a sympathetic dominance in the autonomous nervous system during the CFFT and memory tests, regardless of exposure condition. This might be interpreted as a sign of differences in the autonomous nervous system regulation between persons with MP related subjective symptoms and persons with no such symptoms. (c) 2005 Wiley-Liss, Inc.
Flicker Vision of Selected Light Sources
NASA Astrophysics Data System (ADS)
Otomański, Przemysław; Wiczyński, Grzegorz; Zając, Bartosz
2017-10-01
The results of the laboratory research concerning a dependence of flicker vision on voltage fluctuations are presented in the paper. The research was realized on a designed measuring stand, which included an examined light source, a voltage generator with amplitude modulation supplying the light source and a positioning system of the observer with respect to the observed surface. In this research, the following light sources were used: one incandescent lamp and four LED luminaires by different producers. The research results formulate a conclusion concerning the description of the influence of voltage fluctuations on flicker viewing for selected light sources. The research results indicate that LED luminaires are less susceptible to voltage fluctuations than incandescent bulbs and that flicker vision strongly depends on the type of LED source.
Multi-sensor image fusion algorithm based on multi-objective particle swarm optimization algorithm
NASA Astrophysics Data System (ADS)
Xie, Xia-zhu; Xu, Ya-wei
2017-11-01
On the basis of DT-CWT (Dual-Tree Complex Wavelet Transform - DT-CWT) theory, an approach based on MOPSO (Multi-objective Particle Swarm Optimization Algorithm) was proposed to objectively choose the fused weights of low frequency sub-bands. High and low frequency sub-bands were produced by DT-CWT. Absolute value of coefficients was adopted as fusion rule to fuse high frequency sub-bands. Fusion weights in low frequency sub-bands were used as particles in MOPSO. Spatial Frequency and Average Gradient were adopted as two kinds of fitness functions in MOPSO. The experimental result shows that the proposed approach performances better than Average Fusion and fusion methods based on local variance and local energy respectively in brightness, clarity and quantitative evaluation which includes Entropy, Spatial Frequency, Average Gradient and QAB/F.
Temporal dynamics of divided spatial attention
Garcia, Javier O.; Serences, John T.
2013-01-01
In naturalistic settings, observers often have to monitor multiple objects dispersed throughout the visual scene. However, the degree to which spatial attention can be divided across spatially noncontiguous objects has long been debated, particularly when those objects are in close proximity. Moreover, the temporal dynamics of divided attention are unclear: is the process of dividing spatial attention gradual and continuous, or does it onset in a discrete manner? To address these issues, we recorded steady-state visual evoked potentials (SSVEPs) as subjects covertly monitored two flickering targets while ignoring an intervening distractor that flickered at a different frequency. All three stimuli were clustered within either the lower left or the lower right quadrant, and our dependent measure was SSVEP power at the target and distractor frequencies measured over time. In two experiments, we observed a temporally discrete increase in power for target- vs. distractor-evoked SSVEPs extending from ∼350 to 150 ms prior to correct (but not incorrect) responses. The divergence in SSVEP power immediately prior to a correct response suggests that spatial attention can be divided across noncontiguous locations, even when the targets are closely spaced within a single quadrant. In addition, the division of spatial attention appears to be relatively discrete, as opposed to slow and continuous. Finally, the predictive relationship between SSVEP power and behavior demonstrates that these neurophysiological measures of divided attention are meaningfully related to cognitive function. PMID:23390315
Wunsch, Ewa; Koziarska, Dorota; Milkiewicz, Małgorzata; Naprawa, Grzegorz; Nowacki, Przemysław; Hartleb, Marek; Milkiewicz, Piotr
2013-12-01
Liver cirrhosis is associated with latent systemic inflammatory response syndrome as evidenced by elevated levels of proinflammatory cytokines. It has been proposed that inflammatory mediators play a role in the pathogenesis of minimal and overt hepatic encephalopathy (HE); hence, they may also have an effect on health-related quality of life (HRQL). The aim of this study was to investigate the relationship between serum levels of interleukin-1β (IL-1β), IL-6, and IL-18 and the occurrence of minimal HE and HRQL. Forty-two consecutive patients with liver cirrhosis were prospectively enrolled to the study. Minimal HE was detected by the Psychometric Hepatic Encephalopathy Score (PHES) and critical flicker frequency. HRQL was assessed with Chronic Liver Disease Questionnaire and 36-Item Short Form Health Survey (SF-36) questionnaires. The interleukins studied were determined using colorimetric sandwich enzyme-linked immunosorbent assay. Serum levels of interleukins correlated with liver dysfunction, but did not discriminate patients with minimal HE from those with overt or absent HE. IL-1β and IL-6 showed significant correlations with PHES, but showed no relationship with critical flicker frequency. Serum IL-6 and IL-18 correlated with both physical-related general health and mental component summary evaluated by the SF-36 questionnaire. This study shows that chronic inflammation plays a role in impaired HRQL in patients with cirrhosis irrespective of minimal HE.
Temporal dynamics of divided spatial attention.
Itthipuripat, Sirawaj; Garcia, Javier O; Serences, John T
2013-05-01
In naturalistic settings, observers often have to monitor multiple objects dispersed throughout the visual scene. However, the degree to which spatial attention can be divided across spatially noncontiguous objects has long been debated, particularly when those objects are in close proximity. Moreover, the temporal dynamics of divided attention are unclear: is the process of dividing spatial attention gradual and continuous, or does it onset in a discrete manner? To address these issues, we recorded steady-state visual evoked potentials (SSVEPs) as subjects covertly monitored two flickering targets while ignoring an intervening distractor that flickered at a different frequency. All three stimuli were clustered within either the lower left or the lower right quadrant, and our dependent measure was SSVEP power at the target and distractor frequencies measured over time. In two experiments, we observed a temporally discrete increase in power for target- vs. distractor-evoked SSVEPs extending from ∼350 to 150 ms prior to correct (but not incorrect) responses. The divergence in SSVEP power immediately prior to a correct response suggests that spatial attention can be divided across noncontiguous locations, even when the targets are closely spaced within a single quadrant. In addition, the division of spatial attention appears to be relatively discrete, as opposed to slow and continuous. Finally, the predictive relationship between SSVEP power and behavior demonstrates that these neurophysiological measures of divided attention are meaningfully related to cognitive function.
Low-frequency 1/f noise in graphene devices
NASA Astrophysics Data System (ADS)
Balandin, Alexander A.
2013-08-01
Low-frequency noise with a spectral density that depends inversely on frequency has been observed in a wide variety of systems including current fluctuations in resistors, intensity fluctuations in music and signals in human cognition. In electronics, the phenomenon, which is known as 1/f noise, flicker noise or excess noise, hampers the operation of numerous devices and circuits, and can be a significant impediment to the development of practical applications from new materials. Graphene offers unique opportunities for studying 1/f noise because of its two-dimensional structure and widely tunable two-dimensional carrier concentration. The creation of practical graphene-based devices will also depend on our ability to understand and control the low-frequency noise in this material system. Here, the characteristic features of 1/f noise in graphene and few-layer graphene are reviewed, and the implications of such noise for the development of graphene-based electronics including high-frequency devices and sensors are examined.
Low-frequency 1/f noise in graphene devices.
Balandin, Alexander A
2013-08-01
Low-frequency noise with a spectral density that depends inversely on frequency has been observed in a wide variety of systems including current fluctuations in resistors, intensity fluctuations in music and signals in human cognition. In electronics, the phenomenon, which is known as 1/f noise, flicker noise or excess noise, hampers the operation of numerous devices and circuits, and can be a significant impediment to the development of practical applications from new materials. Graphene offers unique opportunities for studying 1/f noise because of its two-dimensional structure and widely tunable two-dimensional carrier concentration. The creation of practical graphene-based devices will also depend on our ability to understand and control the low-frequency noise in this material system. Here, the characteristic features of 1/f noise in graphene and few-layer graphene are reviewed, and the implications of such noise for the development of graphene-based electronics including high-frequency devices and sensors are examined.
Impact of monaural frequency compression on binaural fusion at the brainstem level.
Klauke, Isabelle; Kohl, Manuel C; Hannemann, Ronny; Kornagel, Ulrich; Strauss, Daniel J; Corona-Strauss, Farah I
2015-08-01
A classical objective measure for binaural fusion at the brainstem level is the so-called β-wave of the binaural interaction component (BIC) in the auditory brainstem response (ABR). However, in some cases it appeared that a reliable detection of this component still remains a challenge. In this study, we investigate the wavelet phase synchronization stability (WPSS) of ABR data for the analysis of binaural fusion and compare it to the BIC. In particular, we examine the impact of monaural nonlinear frequency compression on binaural fusion. As the auditory system is tonotopically organized, an interaural frequency mismatch caused by monaural frequency compression could negatively effect binaural fusion. In this study, only few subjects showed a detectable β-wave and in most cases only for low ITDs. However, we present a novel objective measure for binaural fusion that outperforms the current state-of-the-art technique (BIC): the WPSS analysis showed a significant difference between the phase stability of the sum of the monaurally evoked responses and the phase stability of the binaurally evoked ABR. This difference could be an indicator for binaural fusion in the brainstem. Furthermore, we observed that monaural frequency compression could indeed effect binaural fusion, as the WPSS results for this condition vary strongly from the results obtained without frequency compression.
[An improved medical image fusion algorithm and quality evaluation].
Chen, Meiling; Tao, Ling; Qian, Zhiyu
2009-08-01
Medical image fusion is of very important value for application in medical image analysis and diagnosis. In this paper, the conventional method of wavelet fusion is improved,so a new algorithm of medical image fusion is presented and the high frequency and low frequency coefficients are studied respectively. When high frequency coefficients are chosen, the regional edge intensities of each sub-image are calculated to realize adaptive fusion. The choice of low frequency coefficient is based on the edges of images, so that the fused image preserves all useful information and appears more distinctly. We apply the conventional and the improved fusion algorithms based on wavelet transform to fuse two images of human body and also evaluate the fusion results through a quality evaluation method. Experimental results show that this algorithm can effectively retain the details of information on original images and enhance their edge and texture features. This new algorithm is better than the conventional fusion algorithm based on wavelet transform.
Airborne Infrared and Visible Image Fusion Combined with Region Segmentation
Zuo, Yujia; Liu, Jinghong; Bai, Guanbing; Wang, Xuan; Sun, Mingchao
2017-01-01
This paper proposes an infrared (IR) and visible image fusion method introducing region segmentation into the dual-tree complex wavelet transform (DTCWT) region. This method should effectively improve both the target indication and scene spectrum features of fusion images, and the target identification and tracking reliability of fusion system, on an airborne photoelectric platform. The method involves segmenting the region in an IR image by significance, and identifying the target region and the background region; then, fusing the low-frequency components in the DTCWT region according to the region segmentation result. For high-frequency components, the region weights need to be assigned by the information richness of region details to conduct fusion based on both weights and adaptive phases, and then introducing a shrinkage function to suppress noise; Finally, the fused low-frequency and high-frequency components are reconstructed to obtain the fusion image. The experimental results show that the proposed method can fully extract complementary information from the source images to obtain a fusion image with good target indication and rich information on scene details. They also give a fusion result superior to existing popular fusion methods, based on eithers subjective or objective evaluation. With good stability and high fusion accuracy, this method can meet the fusion requirements of IR-visible image fusion systems. PMID:28505137
Airborne Infrared and Visible Image Fusion Combined with Region Segmentation.
Zuo, Yujia; Liu, Jinghong; Bai, Guanbing; Wang, Xuan; Sun, Mingchao
2017-05-15
This paper proposes an infrared (IR) and visible image fusion method introducing region segmentation into the dual-tree complex wavelet transform (DTCWT) region. This method should effectively improve both the target indication and scene spectrum features of fusion images, and the target identification and tracking reliability of fusion system, on an airborne photoelectric platform. The method involves segmenting the region in an IR image by significance, and identifying the target region and the background region; then, fusing the low-frequency components in the DTCWT region according to the region segmentation result. For high-frequency components, the region weights need to be assigned by the information richness of region details to conduct fusion based on both weights and adaptive phases, and then introducing a shrinkage function to suppress noise; Finally, the fused low-frequency and high-frequency components are reconstructed to obtain the fusion image. The experimental results show that the proposed method can fully extract complementary information from the source images to obtain a fusion image with good target indication and rich information on scene details. They also give a fusion result superior to existing popular fusion methods, based on eithers subjective or objective evaluation. With good stability and high fusion accuracy, this method can meet the fusion requirements of IR-visible image fusion systems.
NASA Astrophysics Data System (ADS)
Tan, Bingyao; Mason, Erik; MacLellan, Ben; Bizheva, Kostadinka
2017-02-01
Visually evoked changes of retinal blood flow can serve as an important research tool to investigate eye disease such as glaucoma and diabetic retinopathy. In this study we used a combined, research-grade, high-resolution Doppler OCT+ERG system to study changes in the retinal blood flow (RBF) and retinal neuronal activity in response to visual stimuli of different intensities, durations and type (flicker vs single flash). Specifically, we used white light stimuli of 10 ms and 200 ms single flash, 1s and 2s for flickers stimuli of 20% duty cycle. The study was conducted in-vivo in pigmented rats. Both single flash (SF) and flicker stimuli caused increase in the RBF. The 10 ms SF stimulus did not generate any consistent measurable response, while the 200 ms SF of the same intensity generated 4% change in the RBF peaking at 1.5 s after the stimulus onset. Single flash stimuli introduced 2x smaller change in RBF and 30% earlier RBF peak response compared to flicker stimuli of the same intensity and duration. Doubling the intensity of SF or flicker stimuli increased the RBF peak magnitude by 1.5x. Shortening the flicker stimulus duration by 2x increased the RBF recovery rate by 2x, however, had no effect on the rate of RBF change from baseline to peak.
Diagnostic capability of Pulsar perimetry in pre-perimetric and early glaucoma.
Hirasawa, Kazunori; Takahashi, Natsumi; Matsumura, Kazuhiro; Kasahara, Masayuki; Shoji, Nobuyuki
2017-06-12
This study aimed to compare the diagnostic capability of Pulsar perimetry (Pulsar) in pre-perimetric glaucoma (PPG) and early glaucoma (EG) with that of Flicker perimetry (Flicker) and spectral-domain optical conference tomography (SD-OCT). This prospective cross-sectional study included 25 eyes of 25 PPG patients, 35 eyes of 35 EG patients, and 42 eyes of 42 healthy participants. The diagnostic capability using the area under the curve (AUC) of the best parameter and agreement of detectability between structural and functional measurements were compared. For PPG patients, the AUC of Pulsar, Flicker, OCT-disc, and OCT-macular was 0.733, 0.663, 0.842, and 0.780, respectively. The AUC of Flicker was significantly lower than that of OCT-disc (p = 0.016). For EG patients, the AUC of Pulsar, Flicker, OCT-disc, and OCT-macular were 0.851, 0.869, 0.907, and 0.861, respectively. There was no significant difference in AUC among these methods. The agreement between structural and functional measurements expressed by kappa value ranged from -0.16 to 0.07 for PPG and from 0.01 to 0.25 for EG. Although the diagnostic capability of Pulsar in the PPG and EG groups was equal to that of Flicker and SD-OCT, the agreements between structural and functional measurements for both PPG and EG were poor.
Macular Pigment Optical Density Measured by Heterochromatic Modulation Photometry
Huchzermeyer, Cord; Schlomberg, Juliane; Welge-Lüssen, Ulrich; Berendschot, Tos T. J. M.; Pokorny, Joel; Kremers, Jan
2014-01-01
Purpose To psychophysically determine macular pigment optical density (MPOD) employing the heterochromatic modulation photometry (HMP) paradigm by estimating 460 nm absorption at central and peripheral retinal locations. Methods For the HMP measurements, two lights (B: 460 nm and R: 660 nm) were presented in a test field and were modulated in counterphase at medium or high frequencies. The contrasts of the two lights were varied in tandem to determine flicker detection thresholds. Detection thresholds were measured for different R:B modulation ratios. The modulation ratio with minimal sensitivity (maximal threshold) is the point of equiluminance. Measurements were performed in 25 normal subjects (11 male, 14 female; age: 30±11 years, mean ± sd) using an eight channel LED stimulator with Maxwellian view optics. The results were compared with those from two published techniques – one based on heterochromatic flicker photometry (Macular Densitometer) and the other on fundus reflectometry (MPR). Results We were able to estimate MPOD with HMP using a modified theoretical model that was fitted to the HMP data. The resultant MPODHMP values correlated significantly with the MPODMPR values and with the MPODHFP values obtained at 0.25° and 0.5° retinal eccentricity. Conclusions HMP is a flicker-based method with measurements taken at a constant mean chromaticity and luminance. The data can be well fit by a model that allows all data points to contribute to the photometric equality estimate. Therefore, we think that HMP may be a useful method for MPOD measurements, in basic and clinical vision experiments. PMID:25354049
Flicker Detection, Measurement and Means of Mitigation: A Review
NASA Astrophysics Data System (ADS)
Virulkar, V. B.; Aware, M. V.
2014-04-01
The voltage fluctuations caused by rapid industrial load change have been a major concern for supply utilities, regulatory agencies and customers. This paper gives a general review about how to examine/assess voltage flicker and methods followed in measuring the flickers due to rapid changing loads and means for its mitigation. It discusses the effects on utilities conditions, compensators response time and compensator capacity of flicker mitigation. A comparison between conventional mitigation techniques and the state-of-art mitigation techniques are carried out. It is shown in many cases that the state-of-art solution provides higher performance compared with conventional mitigation techniques. However, the choice of most suitable solution depends on characteristics of the supply at the point of connection, the requirement of the load and economics.
Sharpening vision by adapting to flicker.
Arnold, Derek H; Williams, Jeremy D; Phipps, Natasha E; Goodale, Melvyn A
2016-11-01
Human vision is surprisingly malleable. A static stimulus can seem to move after prolonged exposure to movement (the motion aftereffect), and exposure to tilted lines can make vertical lines seem oppositely tilted (the tilt aftereffect). The paradigm used to induce such distortions (adaptation) can provide powerful insights into the computations underlying human visual experience. Previously spatial form and stimulus dynamics were thought to be encoded independently, but here we show that adaptation to stimulus dynamics can sharpen form perception. We find that fast flicker adaptation (FFAd) shifts the tuning of face perception to higher spatial frequencies, enhances the acuity of spatial vision-allowing people to localize inputs with greater precision and to read finer scaled text, and it selectively reduces sensitivity to coarse-scale form signals. These findings are consistent with two interrelated influences: FFAd reduces the responsiveness of magnocellular neurons (which are important for encoding dynamics, but can have poor spatial resolution), and magnocellular responses contribute coarse spatial scale information when the visual system synthesizes form signals. Consequently, when magnocellular responses are mitigated via FFAd, human form perception is transiently sharpened because "blur" signals are mitigated.
Sharpening vision by adapting to flicker
Arnold, Derek H.; Williams, Jeremy D.; Phipps, Natasha E.; Goodale, Melvyn A.
2016-01-01
Human vision is surprisingly malleable. A static stimulus can seem to move after prolonged exposure to movement (the motion aftereffect), and exposure to tilted lines can make vertical lines seem oppositely tilted (the tilt aftereffect). The paradigm used to induce such distortions (adaptation) can provide powerful insights into the computations underlying human visual experience. Previously spatial form and stimulus dynamics were thought to be encoded independently, but here we show that adaptation to stimulus dynamics can sharpen form perception. We find that fast flicker adaptation (FFAd) shifts the tuning of face perception to higher spatial frequencies, enhances the acuity of spatial vision—allowing people to localize inputs with greater precision and to read finer scaled text, and it selectively reduces sensitivity to coarse-scale form signals. These findings are consistent with two interrelated influences: FFAd reduces the responsiveness of magnocellular neurons (which are important for encoding dynamics, but can have poor spatial resolution), and magnocellular responses contribute coarse spatial scale information when the visual system synthesizes form signals. Consequently, when magnocellular responses are mitigated via FFAd, human form perception is transiently sharpened because “blur” signals are mitigated. PMID:27791115
Kelly, Simon P; Lalor, Edmund C; Reilly, Richard B; Foxe, John J
2005-06-01
The steady-state visual evoked potential (SSVEP) has been employed successfully in brain-computer interface (BCI) research, but its use in a design entirely independent of eye movement has until recently not been reported. This paper presents strong evidence suggesting that the SSVEP can be used as an electrophysiological correlate of visual spatial attention that may be harnessed on its own or in conjunction with other correlates to achieve control in an independent BCI. In this study, 64-channel electroencephalography data were recorded from subjects who covertly attended to one of two bilateral flicker stimuli with superimposed letter sequences. Offline classification of left/right spatial attention was attempted by extracting SSVEPs at optimal channels selected for each subject on the basis of the scalp distribution of SSVEP magnitudes. This yielded an average accuracy of approximately 71% across ten subjects (highest 86%) comparable across two separate cases in which flicker frequencies were set within and outside the alpha range respectively. Further, combining SSVEP features with attention-dependent parieto-occipital alpha band modulations resulted in an average accuracy of 79% (highest 87%).
Flicker illness: an underrecognized but preventable complication of helicopter transport.
Cushman, Jeremy T; Floccare, Douglas J
2007-01-01
A case report of seizure due to photic stimulation from sunlight shining through spinning helicopter rotor blades is discussed. A review of photosensitive epilepsy is provided with particular emphasis on the effects and frequencies of photic stimulation required to induce symptoms. The frequencies of flashing light produced by spinning helicopter rotor blades commonly used in air medical transport range from 24 to 27 flashes per second. These frequencies are well within the range reported in the literature to produce symptoms in the laboratory setting. The literature provides only a few case reports of individuals sustaining a seizure after photic stimulation from spinning turboprop or helicopter blades. Symptoms range from mild discomfort and headache to profound spatial disorientation and seizures and may be an underrecognized but preventable complication of air medical transport.
CMOS micromachined capacitive cantilevers for mass sensing
NASA Astrophysics Data System (ADS)
Li, Ying-Chung; Ho, Meng-Han; Hung, Shi-Jie; Chen, Meng-Huei; S-C Lu, Michael
2006-12-01
In this paper, we present the design, fabrication and characterization of the CMOS micromachined cantilevers for mass sensing in the femtogram range. The cantilevers consisting of multiple metal and dielectric layers are fabricated after completion of a conventional CMOS process by dry etching steps. The cantilevers are electrostatically actuated to resonance by in-plane electrodes. The mechanical resonant frequency is detected capacitively with on-chip circuitry, where the modulation technique is applied to eliminate capacitive feedthrough from the driving port and to lessen the effect of flicker noise. The highest resonant frequency of the cantilevers is measured at 396.46 kHz with a quality factor of 2600 at 10 mTorr. The resonant frequency shift after deposition of a 0.1 µm SiO2 layer is 140 Hz, averaging 353 fg Hz-1.
Phase noise in RF and microwave amplifiers.
Boudot, Rodolphe; Rubiola, Enrico
2012-12-01
Understanding amplifier phase noise is a critical issue in many fields of engineering and physics, such as oscillators, frequency synthesis, telecommunication, radar, and spectroscopy; in the emerging domain of microwave photonics; and in exotic fields, such as radio astronomy, particle accelerators, etc. Focusing on the two main types of base noise in amplifiers, white and flicker, the power spectral density of the random phase φ(t) is Sφ(f) = b(0) + b(-1)/f. White phase noise results from adding white noise to the RF spectrum in the carrier region. For a given RF noise level, b(0) is proportional to the reciprocal of the carrier power P(0). By contrast, flicker results from a near-dc 1/f noise-present in all electronic devices-which modulates the carrier through some parametric effect in the semiconductor. Thus, b(-1) is a parameter of the amplifier, constant in a wide range of P(0). The consequences are the following: Connecting m equal amplifiers in parallel, b(-1) is 1/m times that of one device. Cascading m equal amplifiers, b(-1) is m times that of one amplifier. Recirculating the signal in an amplifier so that the gain increases by a power of m (a factor of m in decibels) as a result of positive feedback (regeneration), we find that b(-1) is m(2) times that of the amplifier alone. The feedforward amplifier exhibits extremely low b(-1) because the carrier is ideally nulled at the input of its internal error amplifier. Starting with an extensive review of the literature, this article introduces a system-oriented model which describes the phase flickering. Several amplifier architectures (cascaded, parallel, etc.) are analyzed systematically, deriving the phase noise from the general model. There follow numerous measurements of amplifiers using different technologies, including some old samples, and in a wide frequency range (HF to microwaves), which validate the theory. In turn, theory and results provide design guidelines and give suggestions for CAD and simulation. To conclude, this article is intended as a tutorial, a review, and a systematic treatise on the subject, supported by extensive experiments.
78 FR 38953 - Procurement List Additions
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-28
... NSN: 6230-00-NIB-0033--Kit, Safety Flare, Programmable Flicker Pattern, Red LED, 8 in Diameter, AA Battery Operated. NSN: 6230-00-NIB-0034--Kit, Safety Flare, Programmable Flicker Pattern, Red LED, 8 in...
78 FR 23542 - Procurement List; Proposed Additions
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-19
..., Programmable Flicker Pattern, Red LED, 8in Diameter, AA Battery Operated. NSN: 6230-00-NIB-0034--Kit, Safety Flare, Programmable Flicker Pattern, Red LED, 8in Diameter, Rechargeable Power Unit. Coverage: B-List...
Operation of a P300-based brain-computer interface by individuals with cervical spinal cord injury.
Ikegami, Shiro; Takano, Kouji; Saeki, Naokatsu; Kansaku, Kenji
2011-05-01
This study evaluates the efficacy of a P300-based brain-computer interface (BCI) with green/blue flicker matrices for individuals with cervical spinal cord injury (SCI). Ten individuals with cervical SCI (age 26-53, all male) and 10 age- and sex-matched able-bodied controls (age 27-52, all male) with no prior BCI experience were asked to input hiragana (Japanese alphabet) characters using the P300 BCI with two distinct types of visual stimuli, white/gray and green/blue, in an 8×10 flicker matrix. Both online and offline performance were evaluated. The mean online accuracy of the SCI subjects was 88.0% for the white/gray and 90.7% for the green/blue flicker matrices. The accuracy of the control subjects was 77.3% and 86.0% for the white/gray and green/blue, respectively. There was a significant difference in online accuracy between the two types of flicker matrix. SCI subjects performed with greater accuracy than controls, but the main effect was not significant. Individuals with cervical SCI successfully controlled the P300 BCI, and the green/blue flicker matrices were associated with significantly higher accuracy than the white/gray matrices. The P300 BCI with the green/blue flicker matrices is effective for use not only in able-bodied subjects, but also in individuals with cervical SCI. Copyright © 2010 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Bhateja, Vikrant; Moin, Aisha; Srivastava, Anuja; Bao, Le Nguyen; Lay-Ekuakille, Aimé; Le, Dac-Nhuong
2016-07-01
Computer based diagnosis of Alzheimer's disease can be performed by dint of the analysis of the functional and structural changes in the brain. Multispectral image fusion deliberates upon fusion of the complementary information while discarding the surplus information to achieve a solitary image which encloses both spatial and spectral details. This paper presents a Non-Sub-sampled Contourlet Transform (NSCT) based multispectral image fusion model for computer-aided diagnosis of Alzheimer's disease. The proposed fusion methodology involves color transformation of the input multispectral image. The multispectral image in YIQ color space is decomposed using NSCT followed by dimensionality reduction using modified Principal Component Analysis algorithm on the low frequency coefficients. Further, the high frequency coefficients are enhanced using non-linear enhancement function. Two different fusion rules are then applied to the low-pass and high-pass sub-bands: Phase congruency is applied to low frequency coefficients and a combination of directive contrast and normalized Shannon entropy is applied to high frequency coefficients. The superiority of the fusion response is depicted by the comparisons made with the other state-of-the-art fusion approaches (in terms of various fusion metrics).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhateja, Vikrant, E-mail: bhateja.vikrant@gmail.com, E-mail: nhuongld@hus.edu.vn; Moin, Aisha; Srivastava, Anuja
Computer based diagnosis of Alzheimer’s disease can be performed by dint of the analysis of the functional and structural changes in the brain. Multispectral image fusion deliberates upon fusion of the complementary information while discarding the surplus information to achieve a solitary image which encloses both spatial and spectral details. This paper presents a Non-Sub-sampled Contourlet Transform (NSCT) based multispectral image fusion model for computer-aided diagnosis of Alzheimer’s disease. The proposed fusion methodology involves color transformation of the input multispectral image. The multispectral image in YIQ color space is decomposed using NSCT followed by dimensionality reduction using modified Principal Componentmore » Analysis algorithm on the low frequency coefficients. Further, the high frequency coefficients are enhanced using non-linear enhancement function. Two different fusion rules are then applied to the low-pass and high-pass sub-bands: Phase congruency is applied to low frequency coefficients and a combination of directive contrast and normalized Shannon entropy is applied to high frequency coefficients. The superiority of the fusion response is depicted by the comparisons made with the other state-of-the-art fusion approaches (in terms of various fusion metrics).« less
NASA Astrophysics Data System (ADS)
Goad, Pamela Joy
The fusion of musical voices is an important aspect of musical blend, or the mixing of individual sounds. Yet, little research has been done to explicitly determine the factors involved in fusion. In this study, the similarity of timbre and modulation were examined for their contribution to the fusion of sounds. It is hypothesized that similar timbres will fuse better than dissimilar timbres, and, voices with the same kind of modulation will fuse better than voices of different modulations. A perceptually-based measure, known as sharpness was investigated as a measure of timbre. The advantages of using sharpness are that it is based on hearing sensitivities and masking phenomena of inner ear processing. Five musical instrument families were digitally recorded in performances across a typical playing range at two extreme dynamic levels. Analyses reveal that sharpness is capable of uncovering subtle changes in timbre including those found in musical dynamics, instrument design, and performer-specific variations. While these analyses alone are insufficient to address fusion, preliminary calculations of timbral combinations indicate that sharpness has the potential to predict the fusion of sounds used in musical composition. Three experiments investigated the effects of modulation on the fusion of a harmonic major sixth interval. In the first experiment using frequency modulation, stimuli varied in deviation about a mean fundamental frequency and relative modulation phase between the two tones. Results showed smaller frequency deviations promoted fusion and relative phase differences had a minimal effect. In a second experiment using amplitude modulation, stimuli varied in deviation about a mean amplitude level and relative phase of modulation. Results showed smaller amplitude deviations promoted better fusion, but unlike frequency modulation, relative phase differences were also important. In a third experiment, frequency modulation, amplitude modulation and mixed modulation were arranged in all possible voicings. Results showed frequency modulation in the lower voice and less variance in amplitude envelopes contributed to an increase in fusion. The theory that similar modulations would promote better fusion was only marginally supported. For these experiments, results revealed differences depending on modulation type and that a lesser amount of modulation fosters greater fusion.
Stockman, Andrew; Henning, G Bruce; West, Peter; Rider, Andrew T; Ripamonti, Caterina
2017-08-01
When M- or L-cone-isolating sawtooth waveforms flicker at frequencies between 4 and 13.3 Hz, there is a mean hue shift in the direction of the shallower sawtooth slope. Here, we investigate how this shift depends on the alignment of the first and second harmonics of sawtooth-like waveforms. Below 4 Hz, observers can follow hue variations caused by both harmonics, and reliably match reddish and greenish excursions. At higher frequencies, however, the hue variations appear as chromatic flicker superimposed on a steady light, the mean hue of which varies with second-harmonic alignment. Observers can match this mean hue against a variable-duty-cycle rectangular waveform and, separately, set the alignment at which the mean hue flips between reddish and greenish. The maximum hue shifts were approximately frequency independent and occurred when the peaks or troughs of the first and second harmonics roughly aligned at the visual input-consistent with the hue shift's being caused by an early instantaneous nonlinearity that saturates larger hue excursions. These predictions, however, ignore phase delays introduced within the chromatic pathway between its input and the nonlinearity that produces the hue shifts. If the nonlinearity follows the substantial filtering implied by the chromatic temporal contrast-sensitivity function, phase delays will alter the alignment of the first and second harmonics such that at the nonlinearity, the waveforms that produce the maximum hue shifts might well be those with the largest differences in rising and falling slopes-consistent with the hue shift's being caused by a central nonlinearity that limits the rate of hue change.
Evaluating the effectiveness of using electroencephalogram power indices to measure visual fatigue.
Hsu, Bin-Wei; Wang, Mao-Jiun J
2013-02-01
Electroencephalography (EEG) is widely used in cognitive and behavioral research. This study evaluates the effectiveness of using the EEG power index to measure visual fatigue. Three common visual fatigue measures, critical-flicker fusion (CFF), near-point accommodation (NPA), and subjective eye-fatigue rating, were used for comparison. The study participants were 20 men with a mean age of 20.4 yr. (SD = 1.5). The experimental task was a car-racing video game. Results indicated that the EEG power indices were valid as a visual fatigue measure and the sensitivity of the objective measures (CFF and EEG power index) was higher than the subjective measure. The EEG beta and EEG alpha were effective for measuring visual fatigue in short- and long-duration tasks, respectively. EEG beta/alpha were the most effective power indexes for the visual fatigue measure.
Langbein, J.; Bock, Y.
2004-01-01
A network of 13 continuous GPS stations near Parkfield, California has been converted from 30 second to 1 second sampling with positions of the stations estimated in real-time relative to a master station. Most stations are near the trace of the San Andreas fault, which exhibits creep. The noise spectra of the instantaneous 1 Hz positions show flicker noise at high frequencies and change to frequency independence at low frequencies; the change in character occurs between 6 to 8 hours. Our analysis indicates that 1-second sampled GPS can estimate horizontal displacements of order 6 mm at the 99% confidence level from a few seconds to a few hours. High frequency GPS can augment existing measurements in capturing large creep events and postseismic slip that would exceed the range of existing creepmeters, and can detect large seismic displacements. Copyright 2004 by the American Geophysical Union.
Shih, Yen-Yu I.; Wang, Lin; De La Garza, Bryan H.; Li, Guang; Cull, Grant; Kiel, Jeffery W.; Duong, Timothy Q.
2013-01-01
Purpose The present study aimed to quantify retinal and choroidal blood flow (BF) during light, dark adaptation and flicker light stimulation using the microsphere technique. Materials and Methods Adult male Sprague–Dawley rats were anesthetized with isoflurane. Eyes were dark (Group I, n = 8), light (Group II, n = 8) adapted or stimulated with 10Hz flicker light (Group III, n = 10). Retinal and choroidal BF were measured by a previously established method, using a mixture of 8 μm yellow-green and 10 μm red fluorescent microspheres. The microspheres were counted ex vivo in the dissected retina and choroid and in the reference arterial blood under a fluorescent microscope. Results The choroidal BF was 64.8 ± 29 μl/min (mean ± SD) during dark adaptation, not significantly different from that during light adaptation (66.0 ± 17.8 μl/min). The retinal BF was 13.5 ± 3.2 μl/min during 10 Hz flickering light stimulation, significantly higher than that during dark adaptation in the control fellow eyes (9.9 ± 2.9 μl/min). The choroidal BF values were not statistically different between flicker stimulation and dark adaptation. Retinal BF was 11.6 ± 2.9 μl/min during light adaptation. Dark adaptation did not increase retinal BF (Group I, 8.2 ± 2.4 μl/min; Group II, 9.9 ± 2.9 μl/min). Conclusions These findings argue against a dark-induced or flicker-induced functional hyperemia in the choroid as a result of the demands of the outer retina. Retinal BF was not higher during dark adaptation. Our data support the conclusion that the inner retina has a higher energy demand in flicker conditions relative to dark. PMID:23317112
Shih, Yen-Yu I; Wang, Lin; De La Garza, Bryan H; Li, Guang; Cull, Grant; Kiel, Jeffery W; Duong, Timothy Q
2013-02-01
The present study aimed to quantify retinal and choroidal blood flow (BF) during light, dark adaptation and flicker light stimulation using the microsphere technique. Adult male Sprague-Dawley rats were anesthetized with isoflurane. Eyes were dark (Group I, n = 8), light (Group II, n = 8) adapted or stimulated with 10 Hz flicker light (Group III, n = 10). Retinal and choroidal BF were measured by a previously established method, using a mixture of 8 µm yellow-green and 10 µm red fluorescent microspheres. The microspheres were counted ex vivo in the dissected retina and choroid and in the reference arterial blood under a fluorescent microscope. The choroidal BF was 64.8 ± 29 µl/min (mean ± SD) during dark adaptation, not significantly different from that during light adaptation (66.0 ± 17.8 µl/min). The retinal BF was 13.5 ± 3.2 µl/min during 10 Hz flickering light stimulation, significantly higher than that during dark adaptation in the control fellow eyes (9.9 ± 2.9 µl/min). The choroidal BF values were not statistically different between flicker stimulation and dark adaptation. Retinal BF was 11.6 ± 2.9 µl/min during light adaptation. Dark adaptation did not increase retinal BF (Group I, 8.2 ± 2.4 µl/min; Group II, 9.9 ± 2.9 µl/min). These findings argue against a dark-induced or flicker-induced functional hyperemia in the choroid as a result of the demands of the outer retina. Retinal BF was not higher during dark adaptation. Our data support the conclusion that the inner retina has a higher energy demand in flicker conditions relative to dark.
Removing flicker based on sparse color correspondences in old film restoration
NASA Astrophysics Data System (ADS)
Huang, Xi; Ding, Youdong; Yu, Bing; Xia, Tianran
2018-04-01
In the long history of human civilization, archived film is an indispensable part of it, and using digital method to repair damaged film is also a mainstream trend nowadays. In this paper, we propose a sparse color correspondences based technique to remove fading flicker for old films. Our model, combined with multi frame images to establish a simple correction model, includes three key steps. Firstly, we recover sparse color correspondences in the input frames to build a matrix with many missing entries. Secondly, we present a low-rank matrix factorization approach to estimate the unknown parameters of this model. Finally, we adopt a two-step strategy that divide the estimated parameters into reference frame parameters for color recovery correction and other frame parameters for color consistency correction to remove flicker. Our method combined multi-frames takes continuity of the input sequence into account, and the experimental results show the method can remove fading flicker efficiently.
A novel hybrid BCI speller based on the incorporation of SSVEP into the P300 paradigm
NASA Astrophysics Data System (ADS)
Yin, Erwei; Zhou, Zongtan; Jiang, Jun; Chen, Fanglin; Liu, Yadong; Hu, Dewen
2013-04-01
Objective. Although extensive studies have shown improvement in spelling accuracy, the conventional P300 speller often exhibits errors, which occur in almost the same row or column relative to the target. To address this issue, we propose a novel hybrid brain-computer interface (BCI) approach by incorporating the steady-state visual evoked potential (SSVEP) into the conventional P300 paradigm. Approach. We designed a periodic stimuli mechanism and superimposed it onto the P300 stimuli to increase the difference between the symbols in the same row or column. Furthermore, we integrated the random flashings and periodic flickers to simultaneously evoke the P300 and SSVEP, respectively. Finally, we developed a hybrid detection mechanism based on the P300 and SSVEP in which the target symbols are detected by the fusion of three-dimensional, time-frequency features. Main results. The results obtained from 12 healthy subjects show that an online classification accuracy of 93.85% and information transfer rate of 56.44 bit/min were achieved using the proposed BCI speller in only a single trial. Specifically, 5 of the 12 subjects exhibited an information transfer rate of 63.56 bit/min with an accuracy of 100%. Significance. The pilot studies suggested that the proposed BCI speller could achieve a better and more stable system performance compared with the conventional P300 speller, and it is promising for achieving quick spelling in stimulus-driven BCI applications.
Pailian, Hrag; Halberda, Justin
2015-04-01
We investigated the psychometric properties of the one-shot change detection task for estimating visual working memory (VWM) storage capacity-and also introduced and tested an alternative flicker change detection task for estimating these limits. In three experiments, we found that the one-shot whole-display task returns estimates of VWM storage capacity (K) that are unreliable across set sizes-suggesting that the whole-display task is measuring different things at different set sizes. In two additional experiments, we found that the one-shot single-probe variant shows improvements in the reliability and consistency of K estimates. In another additional experiment, we found that a one-shot whole-display-with-click task (requiring target localization) also showed improvements in reliability and consistency. The latter results suggest that the one-shot task can return reliable and consistent estimates of VWM storage capacity (K), and they highlight the possibility that the requirement to localize the changed target is what engenders this enhancement. Through a final series of four experiments, we introduced and tested an alternative flicker change detection method that also requires the observer to localize the changing target and that generates, from response times, an estimate of VWM storage capacity (K). We found that estimates of K from the flicker task correlated with estimates from the traditional one-shot task and also had high reliability and consistency. We highlight the flicker method's ability to estimate executive functions as well as VWM storage capacity, and discuss the potential for measuring multiple abilities with the one-shot and flicker tasks.
Development of a compact optical absolute frequency reference for space with 10-15 instability.
Schuldt, Thilo; Döringshoff, Klaus; Kovalchuk, Evgeny V; Keetman, Anja; Pahl, Julia; Peters, Achim; Braxmaier, Claus
2017-02-01
We report on a compact and ruggedized setup for laser frequency stabilization employing Doppler-free spectroscopy of molecular iodine near 532 nm. Using a 30 cm long iodine cell in a triple-pass configuration in combination with noise-canceling detection and residual amplitude modulation control, a frequency instability of 6×10-15 at 1 s integration time and a Flicker noise floor below 3×10-15 for integration times between 100 and 1000 s was found. A specific assembly-integration technology was applied for the realization of the spectroscopy setup, ensuring high beam pointing stability and high thermal and mechanical rigidity. The setup was developed with respect to future applications in space, including high-sensitivity interspacecraft interferometry, tests of fundamental physics, and navigation and ranging.
Told, Reinhard; Palkovits, Stefan; Boltz, Agnes; Schmidl, Doreen; Napora, Katarzyna J; Werkmeister, René M; Haslacher, Helmuth; Frantal, Sophie; Popa-Cherecheanu, Alina; Schmetterer, Leopold; Garhöfer, Gerhard
2014-11-01
The complement factor H (CFH) tyrosine 402 histidine (Y402H, rs1061170) variant is known to be significantly associated with age-related macular degeneration (AMD). Whether this genetic variant may impact retinal blood flow regulation is largely unknown. This study investigated whether flicker-induced vasodilation, an indicator for the coupling between neural activity and blood flow, is altered in subjects carrying the rs1061170 risk allele. One hundred healthy subjects (aged between 18 and 45 years) were included in this study. Retinal blood flow regulation was tested by assessing retinal vessel calibres in response to stimulation with diffuse flicker light. Retinal vascular flicker responses were determined with a Dynamic Vessel Analyzer (DVA). In addition, genotyping for rs1061170 was performed. Eighteen subjects were homozygous for the risk allele C, 50 were homozygous for the ancestral allele T, and 31 subjects were heterozygous (CT). One subject had to be excluded from data evaluation, as no genetic analysis could be performed due to technical difficulties. Baseline diameters of retinal arteries (p = 0.39) and veins (p = 0.64) were comparable between the three groups. Flicker-induced vasodilation in both retinal arteries (p = 0.38) and retinal veins (p = 0.62) was also comparable between the three studied groups. Our data indicate that homozygous healthy young carriers of the C risk allele at rs1061170 do not show abnormal flicker-induced vasodilation in the retina. This suggests that the high-risk genetic variant of CFH polymorphism does not impact neuro-vascular coupling in healthy subjects. © 2014 The Authors. Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation.
Fisher, Ryan J; Wiebe, Karen L
2006-04-01
To date, most studies of nest site selection have failed to take into account more than one source of nest loss (or have combined all sources in one analysis) when examining nest site characteristics, leaving us with an incomplete understanding of the potential trade-offs that individuals may face when selecting a nest site. Our objectives were to determine whether northern flickers (Colaptes auratus) may experience a trade-off in nest site selection in response to mammalian nest predation and nest loss to a cavity nest competitor (European starling, Sturnus vulgaris). We also document within-season temporal patterns of these two sources of nest loss with the hypothesis that flickers may also be constrained in the timing of reproduction under both predatory and competitive influence. Mammalian predators frequently depredated flicker nests that were: lower to the ground, less concealed by vegetation around the cavity entrance and at the base of the nest tree, closer to coniferous forest edges and in forest clumps with a high percentage of conifer content. Proximity to coniferous edges or coniferous trees increased the probability of nest predation, but nests near conifers were less likely to be lost to starlings. Flickers may thus face a trade-off in nest site selection with respect to safety from predators or competitors. Models suggested that peaks of nest predation and nest loss to eviction occurred at the same time, although a competing model suggested that the peak of nest loss to starlings occurred 5 days earlier than the peak of mammalian predation. Differences in peaks of mammalian predation and loss to starlings may constrain any adjustment in clutch initiation date by flickers to avoid one source of nest loss.
Log-Gabor Energy Based Multimodal Medical Image Fusion in NSCT Domain
Yang, Yong; Tong, Song; Huang, Shuying; Lin, Pan
2014-01-01
Multimodal medical image fusion is a powerful tool in clinical applications such as noninvasive diagnosis, image-guided radiotherapy, and treatment planning. In this paper, a novel nonsubsampled Contourlet transform (NSCT) based method for multimodal medical image fusion is presented, which is approximately shift invariant and can effectively suppress the pseudo-Gibbs phenomena. The source medical images are initially transformed by NSCT followed by fusing low- and high-frequency components. The phase congruency that can provide a contrast and brightness-invariant representation is applied to fuse low-frequency coefficients, whereas the Log-Gabor energy that can efficiently determine the frequency coefficients from the clear and detail parts is employed to fuse the high-frequency coefficients. The proposed fusion method has been compared with the discrete wavelet transform (DWT), the fast discrete curvelet transform (FDCT), and the dual tree complex wavelet transform (DTCWT) based image fusion methods and other NSCT-based methods. Visually and quantitatively experimental results indicate that the proposed fusion method can obtain more effective and accurate fusion results of multimodal medical images than other algorithms. Further, the applicability of the proposed method has been testified by carrying out a clinical example on a woman affected with recurrent tumor images. PMID:25214889
The combined effects of L-theanine and caffeine on cognitive performance and mood.
Owen, Gail N; Parnell, Holly; De Bruin, Eveline A; Rycroft, Jane A
2008-08-01
The aim of this study was to compare 50 mg caffeine, with and without 100 mg L-theanine, on cognition and mood in healthy volunteers. The effects of these treatments on word recognition, rapid visual information processing, critical flicker fusion threshold, attention switching and mood were compared to placebo in 27 participants. Performance was measured at baseline and again 60 min and 90 min after each treatment (separated by a 7-day washout). Caffeine improved subjective alertness at 60 min and accuracy on the attention-switching task at 90 min. The L-theanine and caffeine combination improved both speed and accuracy of performance of the attention-switching task at 60 min, and reduced susceptibility to distracting information in the memory task at both 60 min and 90 min. These results replicate previous evidence which suggests that L-theanine and caffeine in combination are beneficial for improving performance on cognitively demanding tasks.
Saccadic eye movements analysis as a measure of drug effect on central nervous system function.
Tedeschi, G; Quattrone, A; Bonavita, V
1986-04-01
Peak velocity (PSV) and duration (SD) of horizontal saccadic eye movements are demonstrably under the control of specific brain stem structures. Experimental and clinical evidence suggest the existence of an immediate premotor system for saccade generation located in the paramedian pontine reticular formation (PPRF). Effects on saccadic eye movements have been studied in normal volunteers with barbiturates, benzodiazepines, amphetamine and ethanol. On two occasions computer analysis of PSV, SD, saccade reaction time (SRT) and saccade accuracy (SA) was carried out in comparison with more traditional methods of assessment of human psychomotor performance like choice reaction time (CRT) and critical flicker fusion threshold (CFFT). The computer system proved to be a highly sensitive and objective method for measuring drug effect on central nervous system (CNS) function. It allows almost continuous sampling of data and appears to be particularly suitable for studying rapidly changing drug effects on the CNS.
Göbel, K; Erb, C
2013-02-01
The early detection of functional glaucoma damage plays an increasingly more central role in the diagnosis and treatment of glaucoma disease. Using selective perimetry detection of early glaucomatous defects is more likely and one of these methods is flicker perimetry with Pulsar. Flicker perimetry is used to analyze the temporal visual function in combination with spatial resolution and contrast sensitivity as opposed to standard automated perimetry which measures the differential light sensitivity with a non-specific stimulus. This study showed a higher sensitivity and specificity of Pulsar perimetry in comparison to achromatic perimetry in glaucoma patients.
Noise considerations for remote detection of life signs with microwave Doppler radar.
Nguyen, Dung; Yamada, Shuhei; Park, Byung-Kwon; Lubecke, Victor; Boric-Lubecke, Olga; Host-Madsen, Anders
2007-01-01
This paper describes and quantifies three main sources of baseband noise affecting physiological signals in a direct conversion microwave Doppler radar for life signs detection. They are thermal noise, residual phase noise, and Flicker noise. In order to increase the SNR of physiological signals at baseband, the noise floor, in which the Flicker noise is the most dominant factor, needs to be minimized. This paper shows that with the consideration of the noise factor in our Doppler radar, Flicker noise canceling techniques may drastically reduce the power requirement for heart rate signal detection by as much as a factor of 100.
NASA Astrophysics Data System (ADS)
Jin, Xin; Jiang, Qian; Yao, Shaowen; Zhou, Dongming; Nie, Rencan; Lee, Shin-Jye; He, Kangjian
2018-01-01
In order to promote the performance of infrared and visual image fusion and provide better visual effects, this paper proposes a hybrid fusion method for infrared and visual image by the combination of discrete stationary wavelet transform (DSWT), discrete cosine transform (DCT) and local spatial frequency (LSF). The proposed method has three key processing steps. Firstly, DSWT is employed to decompose the important features of the source image into a series of sub-images with different levels and spatial frequencies. Secondly, DCT is used to separate the significant details of the sub-images according to the energy of different frequencies. Thirdly, LSF is applied to enhance the regional features of DCT coefficients, and it can be helpful and useful for image feature extraction. Some frequently-used image fusion methods and evaluation metrics are employed to evaluate the validity of the proposed method. The experiments indicate that the proposed method can achieve good fusion effect, and it is more efficient than other conventional image fusion methods.
Image Fusion of CT and MR with Sparse Representation in NSST Domain
Qiu, Chenhui; Wang, Yuanyuan; Zhang, Huan
2017-01-01
Multimodal image fusion techniques can integrate the information from different medical images to get an informative image that is more suitable for joint diagnosis, preoperative planning, intraoperative guidance, and interventional treatment. Fusing images of CT and different MR modalities are studied in this paper. Firstly, the CT and MR images are both transformed to nonsubsampled shearlet transform (NSST) domain. So the low-frequency components and high-frequency components are obtained. Then the high-frequency components are merged using the absolute-maximum rule, while the low-frequency components are merged by a sparse representation- (SR-) based approach. And the dynamic group sparsity recovery (DGSR) algorithm is proposed to improve the performance of the SR-based approach. Finally, the fused image is obtained by performing the inverse NSST on the merged components. The proposed fusion method is tested on a number of clinical CT and MR images and compared with several popular image fusion methods. The experimental results demonstrate that the proposed fusion method can provide better fusion results in terms of subjective quality and objective evaluation. PMID:29250134
Image Fusion of CT and MR with Sparse Representation in NSST Domain.
Qiu, Chenhui; Wang, Yuanyuan; Zhang, Huan; Xia, Shunren
2017-01-01
Multimodal image fusion techniques can integrate the information from different medical images to get an informative image that is more suitable for joint diagnosis, preoperative planning, intraoperative guidance, and interventional treatment. Fusing images of CT and different MR modalities are studied in this paper. Firstly, the CT and MR images are both transformed to nonsubsampled shearlet transform (NSST) domain. So the low-frequency components and high-frequency components are obtained. Then the high-frequency components are merged using the absolute-maximum rule, while the low-frequency components are merged by a sparse representation- (SR-) based approach. And the dynamic group sparsity recovery (DGSR) algorithm is proposed to improve the performance of the SR-based approach. Finally, the fused image is obtained by performing the inverse NSST on the merged components. The proposed fusion method is tested on a number of clinical CT and MR images and compared with several popular image fusion methods. The experimental results demonstrate that the proposed fusion method can provide better fusion results in terms of subjective quality and objective evaluation.
Piezoelectric Non-linear Nanomechanical Temperature and Acceleration Intensive Clocks (PENNTAC)
2014-05-01
ways to mitigate the resonator flicker noise will be identified. 8 Approved for public release; distribution unlimited. Figure 8: (Top...2 3.0 Mitigation of Anchor Losses and Interfacial Dissipation in AlN Contour-Mode Resonators...6 3.2 1/f Resonator Flicker Noise
Martínez, Francisco J; Márquez, Andrés; Gallego, Sergi; Ortuño, Manuel; Francés, Jorge; Pascual, Inmaculada; Beléndez, Augusto
2015-02-20
Parallel-aligned (PA) liquid-crystal on silicon (LCoS) microdisplays are especially appealing in a wide range of spatial light modulation applications since they enable phase-only operation. Recently we proposed a novel polarimetric method, based on Stokes polarimetry, enabling the characterization of their linear retardance and the magnitude of their associated phase fluctuations or flicker, exhibited by many LCoS devices. In this work we apply the calibrated values obtained with this technique to show their capability to predict the performance of spatially varying phase multilevel elements displayed onto the PA-LCoS device. Specifically we address a series of multilevel phase blazed gratings. We analyze both their average diffraction efficiency ("static" analysis) and its associated time fluctuation ("dynamic" analysis). Two different electrical configuration files with different degrees of flicker are applied in order to evaluate the actual influence of flicker on the expected performance of the diffractive optical elements addressed. We obtain a good agreement between simulation and experiment, thus demonstrating the predictive capability of the calibration provided by the average Stokes polarimetric technique. Additionally, it is obtained that for electrical configurations with less than 30° amplitude for the flicker retardance, they may not influence the performance of the blazed gratings. In general, we demonstrate that the influence of flicker greatly diminishes when the number of quantization levels in the optical element increases.
Research on fusion algorithm of polarization image in tetrolet domain
NASA Astrophysics Data System (ADS)
Zhang, Dexiang; Yuan, BaoHong; Zhang, Jingjing
2015-12-01
Tetrolets are Haar-type wavelets whose supports are tetrominoes which are shapes made by connecting four equal-sized squares. A fusion method for polarization images based on tetrolet transform is proposed. Firstly, the magnitude of polarization image and angle of polarization image can be decomposed into low-frequency coefficients and high-frequency coefficients with multi-scales and multi-directions using tetrolet transform. For the low-frequency coefficients, the average fusion method is used. According to edge distribution differences in high frequency sub-band images, for the directional high-frequency coefficients are used to select the better coefficients by region spectrum entropy algorithm for fusion. At last the fused image can be obtained by utilizing inverse transform for fused tetrolet coefficients. Experimental results show that the proposed method can detect image features more effectively and the fused image has better subjective visual effect
Fusion of infrared and visible images based on BEMD and NSDFB
NASA Astrophysics Data System (ADS)
Zhu, Pan; Huang, Zhanhua; Lei, Hai
2016-07-01
This paper presents a new fusion method based on the adaptive multi-scale decomposition of bidimensional empirical mode decomposition (BEMD) and the flexible directional expansion of nonsubsampled directional filter banks (NSDFB) for visible-infrared images. Compared with conventional multi-scale fusion methods, BEMD is non-parametric and completely data-driven, which is relatively more suitable for non-linear signals decomposition and fusion. NSDFB can provide direction filtering on the decomposition levels to capture more geometrical structure of the source images effectively. In our fusion framework, the entropies of the two patterns of source images are firstly calculated and the residue of the image whose entropy is larger is extracted to make it highly relevant with the other source image. Then, the residue and the other source image are decomposed into low-frequency sub-bands and a sequence of high-frequency directional sub-bands in different scales by using BEMD and NSDFB. In this fusion scheme, two relevant fusion rules are used in low-frequency sub-bands and high-frequency directional sub-bands, respectively. Finally, the fused image is obtained by applying corresponding inverse transform. Experimental results indicate that the proposed fusion algorithm can obtain state-of-the-art performance for visible-infrared images fusion in both aspects of objective assessment and subjective visual quality even for the source images obtained in different conditions. Furthermore, the fused results have high contrast, remarkable target information and rich details information that are more suitable for human visual characteristics or machine perception.
Characteristics of dynamic processing in the visual field of patients with age-related maculopathy
Eisenbarth, Werner; MacKeben, Manfred; Poggel, Dorothe A.
2007-01-01
Purpose To investigate the characteristics of dynamic processing in the visual field of patients with age-related maculopathy (ARM) by measuring motion sensitivity, double-pulse resolution (DPR), and critical flicker fusion. Methods Fourteen subjects with ARM (18 eyes), 14 age-matched controls (19 eyes), and 7 young controls (8 eyes) served as subjects. Motion contrast thresholds were determined by a four-alternative forced-choice (4 afc) staircase procedure with a modification by Kernbach for presenting a plaid (size = 3.8°) moving within a stationary spatial and temporal Gaussian envelope in one of four directions. Measurements were performed on the horizontal meridian at 10°, 20°, 30°, 40°, and 60° eccentricity. DPR was defined as the minimal temporal gap detectable by the subject using a 9-fold interleaved adaptive procedure, with stimuli positioned on concentric rings at 5°, 10°, and 20° eccentricity on the principal and oblique meridians. Critical flicker fusion thresholds (CFF) and the Lanthony D-15 color vision test were applied foveally, and the subjects were free to use their fovea or whatever retinal area they needed to use instead, due to their retinal lesions caused by ARM. All measurements were performed under photopic conditions. Results Motion contrast sensitivity in subjects with ARM was pronouncedly reduced (0.23–0.66 log units, p < 0.01), not only in the macula but in a region up to 20° eccentricity. In the two control groups, motion contrast sensitivity systematically declined with retinal eccentricity (0.009–0.032 log units/degree) and with age (0.01 log units/year). Double-pulse thresholds in healthy subjects were approximately constant in the central visual field and increased outside a radius of 10° (1.73 ms/degree). DPR thresholds were elevated in subjects with ARM (by 23–32 ms, p < 0.01) up to 20° eccentricity, and their foveal CFFs were increased by 5.5 Hz or 14% (p < 0.01) as compared with age-matched controls. Conclusions Dynamic processing properties in subjects with ARM are severely impaired in the central visual field up to 20° eccentricity, which is clearly beyond the borders of the macula. PMID:17882447
Presence of strong harmonics during visual entrainment: a magnetoencephalography study.
Heinrichs-Graham, Elizabeth; Wilson, Tony W
2012-09-01
Visual neurons are known to synchronize their firing with stimuli that flicker at a constant rate (e.g. 12Hz). These so-called visual steady-state responses (VSSR) are a well-studied phenomenon, yet the underlying mechanisms are widely disagreed upon. Furthermore, there is limited evidence that visual neurons may simultaneously synchronize at harmonics of the stimulation frequency. We utilized magnetoencephalography (MEG) to examine synchronization at harmonics of the visual stimulation frequency (18Hz). MEG data were analyzed for event-related-synchronization (ERS) at the fundamental frequency, 36, 54, and 72Hz. We found strong ERS in all bands. Only 31% of participants showed maximum entrainment at the fundamental; others showed stronger entrainment at either 36 or 54Hz. The cortical foci of these responses indicated that the harmonics involved cortices that were partially distinct from the fundamental. These findings suggest that spatially-overlapping subpopulations of neurons are simultaneously entrained at different harmonics of the stimulus frequency. Copyright © 2012 Elsevier B.V. All rights reserved.
Qiu, Chenhui; Wang, Yuanyuan; Guo, Yanen; Xia, Shunren
2018-03-14
Image fusion techniques can integrate the information from different imaging modalities to get a composite image which is more suitable for human visual perception and further image processing tasks. Fusing green fluorescent protein (GFP) and phase contrast images is very important for subcellular localization, functional analysis of protein and genome expression. The fusion method of GFP and phase contrast images based on complex shearlet transform (CST) is proposed in this paper. Firstly the GFP image is converted to IHS model and its intensity component is obtained. Secondly the CST is performed on the intensity component and the phase contrast image to acquire the low-frequency subbands and the high-frequency subbands. Then the high-frequency subbands are merged by the absolute-maximum rule while the low-frequency subbands are merged by the proposed Haar wavelet-based energy (HWE) rule. Finally the fused image is obtained by performing the inverse CST on the merged subbands and conducting IHS-to-RGB conversion. The proposed fusion method is tested on a number of GFP and phase contrast images and compared with several popular image fusion methods. The experimental results demonstrate that the proposed fusion method can provide better fusion results in terms of subjective quality and objective evaluation. © 2018 Wiley Periodicals, Inc.
CALiPER Retail Lamps Study 3.1: Dimming, Flicker, and Power Quality Characteristics of LED A Lamps
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
2014-12-31
This CALiPER report examines the characteristics of a subset of lamps from CALiPER Retail Lamps Study 3 in more detail. Specifically, it focuses on the dimming, power quality, and flicker characteristics of 14 LED A lamps, as controlled by four different retail-available dimmers.
Xie, Jun; Xu, Guanghua; Wang, Jing; Li, Min; Han, Chengcheng; Jia, Yaguang
Steady-state visual evoked potentials (SSVEP) based paradigm is a conventional BCI method with the advantages of high information transfer rate, high tolerance to artifacts and the robust performance across users. But the occurrence of mental load and fatigue when users stare at flickering stimuli is a critical problem in implementation of SSVEP-based BCIs. Based on electroencephalography (EEG) power indices α, θ, θ + α, ratio index θ/α and response properties of amplitude and SNR, this study quantitatively evaluated the mental load and fatigue in both of conventional flickering and the novel motion-reversal visual attention tasks. Results over nine subjects revealed significant mental load alleviation in motion-reversal task rather than flickering task. The interaction between factors of "stimulation type" and "fatigue level" also illustrated the motion-reversal stimulation as a superior anti-fatigue solution for long-term BCI operation. Taken together, our work provided an objective method favorable for the design of more practically applicable steady-state evoked potential based BCIs.
Helping enhances productivity in campo flicker ( Colaptes campestris) cooperative groups
NASA Astrophysics Data System (ADS)
Dias, Raphael Igor; Webster, Michael S.; Macedo, Regina H.
2015-06-01
Reproductive adults in many bird species are assisted by non-breeding auxiliary helpers at the nest, yet the impact of auxiliaries on reproduction is variable and not always obvious. In this study, we tested Hamilton's rule and evaluated the effect of auxiliaries on productivity in the facultative cooperative breeder campo flicker ( Colaptes campestris campestris). Campo flickers have a variable mating system, with some groups having auxiliaries and others lacking them (i.e., unassisted pairs). Most auxiliaries are closely related to the breeding pair (primary auxiliaries), but some auxiliaries (secondary auxiliaries) are unrelated females that joined established groups. We found no effect of breeder quality (body condition) or territory quality (food availability) on group productivity, but the presence of auxiliaries increased the number of fledglings produced relative to unassisted pairs. Nonetheless, the indirect benefit of helping was small and did not outweigh the costs of delayed breeding and so seemed insufficient to explain the evolution of cooperative breeding in campo flickers. We concluded that some ecological constraints must limit dispersal or independent breeding, making staying in the group a "best-of-a-bad-job" situation for auxiliaries.
Helping enhances productivity in campo flicker (Colaptes campestris) cooperative groups.
Dias, Raphael Igor; Webster, Michael S; Macedo, Regina H
2015-06-01
Reproductive adults in many bird species are assisted by non-breeding auxiliary helpers at the nest, yet the impact of auxiliaries on reproduction is variable and not always obvious. In this study, we tested Hamilton's rule and evaluated the effect of auxiliaries on productivity in the facultative cooperative breeder campo flicker (Colaptes campestris campestris). Campo flickers have a variable mating system, with some groups having auxiliaries and others lacking them (i.e., unassisted pairs). Most auxiliaries are closely related to the breeding pair (primary auxiliaries), but some auxiliaries (secondary auxiliaries) are unrelated females that joined established groups. We found no effect of breeder quality (body condition) or territory quality (food availability) on group productivity, but the presence of auxiliaries increased the number of fledglings produced relative to unassisted pairs. Nonetheless, the indirect benefit of helping was small and did not outweigh the costs of delayed breeding and so seemed insufficient to explain the evolution of cooperative breeding in campo flickers. We concluded that some ecological constraints must limit dispersal or independent breeding, making staying in the group a "best-of-a-bad-job" situation for auxiliaries.
Multi-focus image fusion algorithm using NSCT and MPCNN
NASA Astrophysics Data System (ADS)
Liu, Kang; Wang, Lianli
2018-04-01
Based on nonsubsampled contourlet transform (NSCT) and modified pulse coupled neural network (MPCNN), the paper proposes an effective method of image fusion. Firstly, the paper decomposes the source image into the low-frequency components and high-frequency components using NSCT, and then processes the low-frequency components by regional statistical fusion rules. For high-frequency components, the paper calculates the spatial frequency (SF), which is input into MPCNN model to get relevant coefficients according to the fire-mapping image of MPCNN. At last, the paper restructures the final image by inverse transformation of low-frequency and high-frequency components. Compared with the wavelet transformation (WT) and the traditional NSCT algorithm, experimental results indicate that the method proposed in this paper achieves an improvement both in human visual perception and objective evaluation. It indicates that the method is effective, practical and good performance.
Comparative visual function in four piscivorous fishes inhabiting Chesapeake Bay.
Horodysky, Andrij Z; Brill, Richard W; Warrant, Eric J; Musick, John A; Latour, Robert J
2010-05-01
Maintaining optimal visual performance is a difficult task in photodynamic coastal and estuarine waters because of the unavoidable tradeoffs between luminous sensitivity and spatial and temporal resolution, yet the visual systems of coastal piscivores remain understudied despite differences in their ecomorphology and microhabitat use. We therefore used electroretinographic techniques to describe the light sensitivities, temporal properties and spectral sensitivities of the visual systems of four piscivorous fishes common to coastal and estuarine waters of the western North Atlantic: striped bass (Morone saxatilis), bluefish (Pomatomus saltatrix), summer flounder (Paralichthys dentatus) and cobia (Rachycentron canadum). Benthic summer flounder exhibited higher luminous sensitivity and broader dynamic range than the three pelagic foragers. The former were at the more sensitive end of an emerging continuum for coastal fishes. By contrast, pelagic species were comparatively less sensitive, but showed larger day-night differences, consistent with their use of diel light-variant photic habitats. Flicker fusion frequency experiments revealed significant interspecific differences at maximum intensities that correlated with lifestyle and habitat. Spectral responses of most species spanned 400-610 nm, with significant day-night differences in striped bass and bluefish. Anadromous striped bass additionally responded to longer wavelengths, similar to many freshwater fishes. Collectively, these results suggest that pelagic piscivores are well adapted to bright photoclimates, which may be at odds with the modern state of eutrified coastal and estuarine waters that they utilize. Recent anthropogenic degradation of water quality in coastal environments, at a pace faster than the evolution of visual systems, may impede visually foraging piscivores, change selected prey, and eventually restructure ecosystems.
García-Gea, Consuelo; Martínez, Joan; Ballester, Maria Rosa; Gich, Ignasi; Valiente, Román; Antonijoan, Rosa Maria
2014-03-01
The aim of this study was to compare the effects of concomitant administration of alcohol and bilastine versus alcohol alone on the central nervous system. Twenty-four healthy young volunteers of both sexes participated in a randomized, double-blind, double-dummy, crossover, and positive-controlled and placebo-controlled clinical trials. At 1-week intervals, subjects received six different treatments: (i) placebo; (ii) alcohol 0.8 g/kg alone (ALC); (iii) ALC in combination with: bilastine 20 mg (B20 + A); (iv) bilastine 80 mg (B80 + A); (v) cetirizine 10 mg (CET + A); and (vi) hydroxyzine 25 mg (HYD + A). Psychomotor performance tests (fine motor, finger tapping, nystagmus, critical flicker-fusion frequency, temporal estimation, 'd2' cancellation, and simple reaction time) and subjective self-reports (drunkenness, drowsiness, mental slowness, clumsiness, anger, attentiveness, competence, happiness, hostility, interest, and extroversion) were carried out at baseline and multiple points thereafter. All active treatments induced a significant psychomotor impairment. The greatest and most lasting impairment was observed with HYD + A followed by B80 + A and CET + A. In contrast, objective measures showed less impairment with B20 + A and ALC, both with a similar magnitude. Self-reports showed a subjective perception of performance impairment in all active treatments. Concomitant administration of bilastine (at therapeutic dose) and alcohol does not produce greater central nervous system depressant effects than ACL alone. Copyright © 2014 John Wiley & Sons, Ltd.
Photovoltaic restoration of sight in rodents with retinal degeneration (Conference Presentation)
NASA Astrophysics Data System (ADS)
Palanker, Daniel V.
2017-02-01
To restore vision in patients who lost their photoreceptors due to retinal degeneration, we developed a photovoltaic subretinal prosthesis which converts light into pulsed electric current, stimulating the nearby inner retinal neurons. Visual information is projected onto the retina by video goggles using pulsed near-infrared ( 900nm) light. This design avoids the use of bulky electronics and wiring, thereby greatly reducing the surgical complexity. Optical activation of the photovoltaic pixels allows scaling the implants to thousands of electrodes, and multiple modules can be tiled under the retina to expand the visual field. We found that similarly to normal vision, retinal response to prosthetic stimulation exhibits flicker fusion at high frequencies (>20Hz), adaptation to static images, and non-linear summation of subunits in the receptive fields. Photovoltaic arrays with 70um pixels restored visual acuity up to a single pixel pitch, which is only two times lower than natural acuity in rats. If these results translate to human retina, such implants could restore visual acuity up to 20/250. With eye scanning and perceptual learning, human patients might even cross the 20/200 threshold of legal blindness. In collaboration with Pixium Vision, we are preparing this system (PRIMA) for a clinical trial. To further improve visual acuity, we are developing smaller pixels - down to 40um, and on 3-D interface to improve proximity to the target neurons. Scalability, ease of implantation and tiling of these wireless modules to cover a large visual field, combined with high resolution opens the door to highly functional restoration of sight.
Liu, Xi-Wen; Bian, Ka; Wen, Zhi-Hong; Li, Xiao-Jing; Zhang, Zuo-Ming; Hu, Wen-Dong
2014-01-01
Objective We evaluated a variety of non-invasive physiological technologies and a series of test approaches for examination of aviator performances under conditions of mental workload in order to provide a standard real-time test for physiological and psychological pilot fatigue assessments. Methods Twenty-one male aviators were selected for a simulated flight in a hypobaric cabin with artificial altitude conditions of 2400 meter above sea level. The simulated flight lasted for 1.5 h, and was repeated for two times with an intervening 0.5 h rest period outside the hypobaric cabin. Subjective criteria (a fatigue assessment instrument [FAI]) and objective criteria (a standing-position balance test as well as a critical flicker fusion frequency (CFF) test) were used for fatigue evaluations. Results No significant change was observed in the FAI scores before and after the simulated flight, indicating that there was no subjective fatigue feeling among the participants. However, significant differences were observed in the standing-position balance and CFF tests among the subjects, suggesting that psychophysiological indexes can reflect mental changes caused by workload to a certain extent. The CFF test was the simplest and clearly indicated the occurrence of workload influences on pilot performances after a simulated flight. Conclusions Results showed that the CFF test was the easiest way to detect workload caused mental changes after a simulated flight in a hypobaric cabin and reflected the psychophysiological state of aviators. We suggest that this test might be used as an effective routine method for evaluating the workload influences on mental conditions of aviators. PMID:24505277
ELECTRICAL STUDIES ON THE COMPOUND EYE OF LIGIA OCCIDENTALIS DANA (CRUSTACEA: ISOPODA)
Ruck, Philip; Jahn, Theodore L.
1954-01-01
The ERG of the compound eye in freshly collected Ligia occidentalis, in response to high intensity light flashes of ⅛ second or longer duration, begins with a negative on-effect quickly followed by an early positive deflection, rapidly returns to the baseline during illumination, and ends with a positive off-effect. As the stimulus intensity is decreased the early positivity progressively decreases and the rapid return to the baseline is replaced by a slowing decline of the negative on-effect. Responses were recorded with one active electrode subcorneally situated in the illuminated eye, the reference electrode in the dark eye. The dark-adapted eye shows a facilitation of the amplitude and rates of rise and fall of the on-effect to a brief, high intensity light stimulus. This facilitation may persist for more than 2 minutes. Following light adaptation under conditions in which the human eye loses sensitivity by a factor of almost 40,000 the Ligia eye loses sensitivity by a factor of only 3. The flicker fusion frequency of the ERG may be as high as 120/second with a corneal illumination of 15,000 foot-candles. Bleeding an otherwise intact animal very rapidly results in a decline of amplitude, change of wave form, and loss of facilitation in the ERG. When the eye is deganglionated without bleeding the animal the isolated retina responds in the same manner as the intact eye. Histological examination of the Ligia receptor layer showed that each ommatidium contains three different retinula cell types, each of which may be responsible for a different aspect of the ERG. PMID:13174786
Heitmar, R; Varma, C; De, P; Lau, Y C; Blann, A D
2016-11-01
To test the hypothesis of a significant relationship between systemic markers of renal and vascular function (processes linked to cardiovascular disease and its development) and retinal microvascular function in diabetes and/or cardiovascular disease. Ocular microcirculatory function was measured in 116 patients with diabetes and/or cardiovascular disease using static and continuous retinal vessel responses to three cycles of flickering light. Endothelial function was evaluated by von Willebrand factor (vWf), endothelial microparticles and soluble E selectin, renal function by serum creatinine, creatinine clearance and estimated glomerular filtration rate (eGFR). HbA1c was used as a control index. Central retinal vein equivalence and venous maximum dilation to flicker were linked to HbA1c (both p < 0.05). Arterial reaction time was linked to serum creatinine (p = 0.036) and eGFR (p = 0.039); venous reaction time was linked to creatinine clearance (p = 0.018). Creatinine clearance and eGFR were linked to arterial maximum dilatation (p < 0.001 and p = 0.003, respectively) and the dilatation amplitude (p = 0.038 and p = 0.048, respectively) responses in the third flicker cycle. Of venous responses to the first flicker cycle, HbA1c was linked to the maximum dilation response (p = 0.004) and dilatation amplitude (p = 0.017), vWf was linked to the maximum constriction response (p = 0.016), and creatinine clearance to the baseline diameter fluctuation (p = 0.029). In the second flicker cycle, dilatation amplitude was linked to serum creatinine (p = 0.022). Several retinal blood vessel responses to flickering light are linked to glycaemia and renal function, but only one index is linked to endothelial function. Renal function must be considered when interpreting retinal vessel responses.
Adaptation mechanisms, eccentricity profiles, and clinical implementation of red-on-white perimetry.
Zele, Andrew J; Dang, Trung M; O'Loughlin, Rebecca K; Guymer, Robyn H; Harper, Alex; Vingrys, Algis J
2008-05-01
To determine the visual adaptation and retinal eccentricity profiles for red flickering and static test stimuli and report a clinical implementation of these stimuli in visual perimetry. The adaptation profile for red-on-white perimetry stimuli was measured using a threshold vs. intensity (TvI) paradigm at 0 degree and 12 degrees eccentricity and by comparing the eccentricity-related sensitivity change for red and white, static, and flickering targets in young normal trichromats (n = 5) and a group of dichromats (n = 5). A group of older normal control observers (n = 30) were tested and retinal disease was evaluated in persons having age-related maculopathy (n = 35) and diabetes (n = 12). Adaptation and eccentricity profiles indicate red static and flickering targets are detected by two mechanisms in the paramacular region, and a single mechanism for >5 degrees eccentricity. The group data for the older normal observers has a high level of inter-observer variability with a generalized reduction in sensitivity across the entire visual field. Group data for the participants with age-related maculopathy show reduced sensitivities that were pronounced in the central retina. The group data for the diabetic observers showed sensitivities that were reduced at all eccentricities. The disease-related sensitivity decline was more apparent with red than white stimuli. The adaptation profile and change in sensitivity with retinal eccentricity for the red-on-white perimetric stimuli are consistent with two detection processes. In the macula, the putative detection mechanism is color-opponent with static targets and non-opponent with flickering targets. At peripheral field locations, the putative detection mechanism is non-opponent for both static and flicker targets. The long-wavelength stimuli are less affected by the preretinal absorption common to aging. Red-on-white static and flicker perimetry may be useful for monitoring retinal disease, revealing greater abnormalities compared with conventional white-on-white perimetry, especially in the macula where two detection mechanisms are found.
Retinal vessel diameters and reactivity in diabetes mellitus and/or cardiovascular disease.
Heitmar, R; Lip, G Y H; Ryder, R E; Blann, A D
2017-04-26
Retinal vessel calibre and vascular dilation/constriction in response to flicker light provocation may provide a measure distinguishing patients suffering from diabetes mellitus and/or cardiovascular disease. One hundred and sixteen age and sex matched patients with diabetes mellitus (DM), cardiovascular disease (CVD) and both DM and CVD (DM + CVD) underwent systemic and intraocular pressure measurements. Retinal vessel calibres were assessed using a validated computer-based program to compute central retinal artery and vein equivalents (CRVE) from monochromatic retinal images. Vessel dilation and constriction responses to flicker light provocation were assessed by continuous retinal vessel diameter recordings. Plasma endothelial markers von Willebrand factor (vWf) and soluble E selectin (sEsel) were measured by ELISA. Retinal vessel calibres were comparable across groups but CRVE correlated significantly with disease duration in DM patients (r = 0.57, p < 0.001). Patients suffering DM only exhibited reduced arterial vasomotion at rest and reduced arterial constriction following flicker light induced vessel dilation compared to patients with CVD and those suffering both CVD + DM (p = 0.030). Patients suffering from CVD + DM exhibited significant differences between each flicker cycle in regards to arterial maximum constriction (p = 0.006) and time needed to reach arterial maximum dilation (p = 0.004), whereas the other two groups did not show such inconsistencies between individual flicker cycles. vWf was raised in CVD + DM compared to the other two groups (p ≤ 0.02), whilst sEsel was raised in CVD + DM compared to DM alone (p = 0.044). Dynamic retinal vascular calibres as obtained by continuous diameter measurements using flicker light provocation can reveal subtle differences between groups suffering from CVD with and without DM. This difference in reaction pattern and lack of arterial constriction in DM may provide a suitable marker to monitor progression.
NASA Technical Reports Server (NTRS)
Stanley, William D.
1994-01-01
An investigation of the Allan variance method as a possible means for characterizing fluctuations in radiometric noise diodes has been performed. The goal is to separate fluctuation components into white noise, flicker noise, and random-walk noise. The primary means is by discrete-time processing, and the study focused primarily on the digital processes involved. Noise satisfying the requirements was generated by direct convolution, fast Fourier transformation (FFT) processing in the time domain, and FFT processing in the frequency domain. Some of the numerous results obtained are presented along with the programs used in the study.
NASA Astrophysics Data System (ADS)
Ebrahimi Orimi, H.; Esmaeili, M.; Refahi Oskouei, A.; Mirhadizadehd, S. A.; Tse, P. W.
2017-10-01
Condition monitoring of rotary devices such as helical gears is an issue of great significance in industrial projects. This paper introduces a feature extraction method for gear fault diagnosis using wavelet packet due to its higher frequency resolution. During this investigation, the mother wavelet Daubechies 10 (Db-10) was applied to calculate the coefficient entropy of each frequency band of 5th level (32 frequency bands) as features. In this study, the peak value of the signal entropies was selected as applicable features in order to improve frequency band differentiation and reduce feature vectors' dimension. Feature extraction is followed by the fusion network where four different structured multi-layer perceptron networks are trained to classify the recorded signals (healthy/faulty). The robustness of fusion network outputs is greater compared to perceptron networks. The results provided by the fusion network indicate a classification of 98.88 and 97.95% for healthy and faulty classes, respectively.
Real-time film recording from stroke-written CRT's
NASA Technical Reports Server (NTRS)
Hunt, R.; Grunwald, A. J.
1980-01-01
Real-time simulation studies often require motion-picture recording of events directly from stroke written cathode-ray tubes (CRT's). Difficulty presented is prevention of "flicker," which results from lack of synchronization between display sequence on CRT and shutter motion of camera. Programmable method has been devised for phasing display sequence to shutter motion, ensuring flicker-free recordings.
Human lateral geniculate nucleus and visual cortex respond to screen flicker.
Krolak-Salmon, Pierre; Hénaff, Marie-Anne; Tallon-Baudry, Catherine; Yvert, Blaise; Guénot, Marc; Vighetto, Alain; Mauguière, François; Bertrand, Olivier
2003-01-01
The first electrophysiological study of the human lateral geniculate nucleus (LGN), optic radiation, striate, and extrastriate visual areas is presented in the context of presurgical evaluation of three epileptic patients (Patients 1, 2, and 3). Visual-evoked potentials to pattern reversal and face presentation were recorded with depth intracranial electrodes implanted stereotactically. For Patient 1, electrode anatomical registration, structural magnetic resonance imaging, and electrophysiological responses confirmed the location of two contacts in the geniculate body and one in the optic radiation. The first responses peaked approximately 40 milliseconds in the LGN in Patient 1 and 60 milliseconds in the V1/V2 complex in Patients 2 and 3. Moreover, steady state visual-evoked potentials evoked by the unperceived but commonly experienced video-screen flicker were recorded in the LGN, optic radiation, and V1/V2 visual areas. This study provides topographic and temporal propagation characteristics of steady state visual-evoked potentials along human visual pathways. We discuss the possible relationship between the oscillating signal recorded in subcortical and cortical areas and the electroencephalogram abnormalities observed in patients suffering from photosensitive epilepsy, particularly video-game epilepsy. The consequences of high temporal frequency visual stimuli delivered by ubiquitous video screens on epilepsy, headaches, and eyestrain must be considered.
NASA Astrophysics Data System (ADS)
Kim, Min Su; Bos, Philip J.; Kim, Dong-Woo; Yang, Deng-Ke; Lee, Joong Hee; Lee, Seung Hee
2016-10-01
Technology of displaying static images in portable displays, advertising panels and price tags pursues significant reduction in power consumption and in product cost. Driving at a low-frequency electric field in fringe-field switching (FFS) mode can be one of the efficient ways to save powers of the recent portable devices, but a serious drop of image-quality, so-called image-flickering, has been found in terms of the coupling of elastic deformation to not only quadratic dielectric effect but linear flexoelectric effect. Despite of the urgent requirement of solving the issue, understanding of such a phenomenon is yet vague. Here, we thoroughly analyze and firstly report the flexoelectric effect in in-plane switching (IPS) liquid crystal cell. The effect takes place on the area above electrodes due to splay and bend deformations of nematic liquid crystal along oblique electric fields, so that the obvious spatial shift of the optical transmittance is experimentally observed and is clearly demonstrated based on the relation between direction of flexoelectric polarization and electric field polarity. In addition, we report that the IPS mode has inherent characteristics to solve the image-flickering issue in the low-power consumption display in terms of the physical property of liquid crystal material and the electrode structure.
Zubov, A V; Zubov, K V; Zubov, V A
2007-01-01
The distribution of water clusters in fresh rain water and in rain water that was aged for 30 days (North Germany, 53 degrees 33' N, 12 degrees 47' E, 293 K, rain on 25.06.06) as well as in fresh vegetables and fruits was studied by flicker noise spectroscopy. In addition, the development of water clusters in apples and potatoes during ripening in 2006 was investigated. A different distribution of water clusters in irrigation water (river and rain) and in the biomatrix of vegetables (potatoes, onions, tomatoes, red beets) and fruits (apples, bananas) was observed. It was concluded that the cluster structure of irrigation water differs from that of water of the biomatrix of vegetables and fruits and depends on drought and the biomatrix nature. Water clusters in plants are more stable and reproducible than water clusters in natural water. The main characteristics of cluster formation in materials studied were given. The oscillation frequencies of water clusters in plants (biofield) are given at which they interact with water clusters of the Earth hydrosphere. A model of series of clusters 16(H2O)100 <--> 4(H2O)402 <--> 2(H2O)903 <--> (H2O)1889 in the biomatrix of vegetables and fruits was discussed.
Kim, Min Su; Bos, Philip J; Kim, Dong-Woo; Yang, Deng-Ke; Lee, Joong Hee; Lee, Seung Hee
2016-10-12
Technology of displaying static images in portable displays, advertising panels and price tags pursues significant reduction in power consumption and in product cost. Driving at a low-frequency electric field in fringe-field switching (FFS) mode can be one of the efficient ways to save powers of the recent portable devices, but a serious drop of image-quality, so-called image-flickering, has been found in terms of the coupling of elastic deformation to not only quadratic dielectric effect but linear flexoelectric effect. Despite of the urgent requirement of solving the issue, understanding of such a phenomenon is yet vague. Here, we thoroughly analyze and firstly report the flexoelectric effect in in-plane switching (IPS) liquid crystal cell. The effect takes place on the area above electrodes due to splay and bend deformations of nematic liquid crystal along oblique electric fields, so that the obvious spatial shift of the optical transmittance is experimentally observed and is clearly demonstrated based on the relation between direction of flexoelectric polarization and electric field polarity. In addition, we report that the IPS mode has inherent characteristics to solve the image-flickering issue in the low-power consumption display in terms of the physical property of liquid crystal material and the electrode structure.
An infrared-visible image fusion scheme based on NSCT and compressed sensing
NASA Astrophysics Data System (ADS)
Zhang, Qiong; Maldague, Xavier
2015-05-01
Image fusion, as a research hot point nowadays in the field of infrared computer vision, has been developed utilizing different varieties of methods. Traditional image fusion algorithms are inclined to bring problems, such as data storage shortage and computational complexity increase, etc. Compressed sensing (CS) uses sparse sampling without knowing the priori knowledge and greatly reconstructs the image, which reduces the cost and complexity of image processing. In this paper, an advanced compressed sensing image fusion algorithm based on non-subsampled contourlet transform (NSCT) is proposed. NSCT provides better sparsity than the wavelet transform in image representation. Throughout the NSCT decomposition, the low-frequency and high-frequency coefficients can be obtained respectively. For the fusion processing of low-frequency coefficients of infrared and visible images , the adaptive regional energy weighting rule is utilized. Thus only the high-frequency coefficients are specially measured. Here we use sparse representation and random projection to obtain the required values of high-frequency coefficients, afterwards, the coefficients of each image block can be fused via the absolute maximum selection rule and/or the regional standard deviation rule. In the reconstruction of the compressive sampling results, a gradient-based iterative algorithm and the total variation (TV) method are employed to recover the high-frequency coefficients. Eventually, the fused image is recovered by inverse NSCT. Both the visual effects and the numerical computation results after experiments indicate that the presented approach achieves much higher quality of image fusion, accelerates the calculations, enhances various targets and extracts more useful information.
Coherent Activity in Bilateral Parieto-Occipital Cortices during P300-BCI Operation.
Takano, Kouji; Ora, Hiroki; Sekihara, Kensuke; Iwaki, Sunao; Kansaku, Kenji
2014-01-01
The visual P300 brain-computer interface (BCI), a popular system for electroencephalography (EEG)-based BCI, uses the P300 event-related potential to select an icon arranged in a flicker matrix. In earlier studies, we used green/blue (GB) luminance and chromatic changes in the P300-BCI system and reported that this luminance and chromatic flicker matrix was associated with better performance and greater subject comfort compared with the conventional white/gray (WG) luminance flicker matrix. To highlight areas involved in improved P300-BCI performance, we used simultaneous EEG-fMRI recordings and showed enhanced activities in bilateral and right lateralized parieto-occipital areas. Here, to capture coherent activities of the areas during P300-BCI, we collected whole-head 306-channel magnetoencephalography data. When comparing functional connectivity between the right and left parieto-occipital channels, significantly greater functional connectivity in the alpha band was observed under the GB flicker matrix condition than under the WG flicker matrix condition. Current sources were estimated with a narrow-band adaptive spatial filter, and mean imaginary coherence was computed in the alpha band. Significantly greater coherence was observed in the right posterior parietal cortex under the GB than under the WG condition. Re-analysis of previous EEG-based P300-BCI data showed significant correlations between the power of the coherence of the bilateral parieto-occipital cortices and their performance accuracy. These results suggest that coherent activity in the bilateral parieto-occipital cortices plays a significant role in effectively driving the P300-BCI.
Heinrichs-Graham, Elizabeth; McDermott, Timothy J.; Mills, Mackenzie S.; Coolidge, Nathan M.; Wilson, Tony W.
2017-01-01
Transcranial direct-current stimulation (tDCS) is a noninvasive neuromodulatory method that involves delivering low amplitude, direct current to specific regions of the brain. While a wealth of literature shows changes in behavior and cognition following tDCS administration, the underlying neuronal mechanisms remain largely unknown. Neuroimaging studies have generally used fMRI and shown only limited consensus to date, while the few electrophysiological studies have reported mostly null or counterintuitive findings. The goal of the current investigation was to quantify tDCS-induced alterations in the oscillatory dynamics of visual processing. To this end, we performed either active or sham tDCS using an occipital-frontal electrode configuration, and then recorded magnetoencephalography (MEG) offline during a visual entrainment task. Significant oscillatory responses were imaged in the time-frequency domain using beamforming, and the effects of tDCS on absolute and relative power were assessed. The results indicated significantly increased basal alpha levels in the occipital cortex following anodal tDCS, as well as reduced occipital synchronization at the second harmonic of the stimulus-flicker frequency relative to sham stimulation. In addition, we found reduced power in brain regions near the cathode (e.g., right inferior frontal gyrus) following active tDCS, which was absent in the sham group. Taken together, these results suggest that anodal tDCS of the occipital cortices differentially modulates spontaneous and induced activity, and may interfere with the entrainment of neuronal populations by a visual-flicker stimulus. These findings also demonstrate the importance of electrode configuration on whole-brain dynamics, and highlight the deceptively complicated nature of tDCS in the context of neurophysiology. PMID:28042984
NASA Astrophysics Data System (ADS)
Fu, Guangwei; Li, Kuixing; Fu, Xinghu; Bi, Weihong
2013-07-01
During the fusion splicing Hollow Core Photonic Crystal Fiber (HC-PCF), the air-holes collapse easily due to the improper fusion duration time and optical power. To analyze the temperature characteristics of fusion splicing HC-PCF, a heating method by sinusoidal modulation CO2 laser has been proposed. In the sinusoidal modulation, the variation relationships among laser power, temperature difference and angular frequency are analyzed. The results show that the theoretical simulation is basically in accordance with the experimental data. Therefore, a low-loss fusion splicing can be achieved by modulating the CO2 laser frequency to avoid the air-holes collapse of HC-PCF. Further, the errors are also given.
Asynchronous BCI control using high-frequency SSVEP.
Diez, Pablo F; Mut, Vicente A; Avila Perona, Enrique M; Laciar Leber, Eric
2011-07-14
Steady-State Visual Evoked Potential (SSVEP) is a visual cortical response evoked by repetitive stimuli with a light source flickering at frequencies above 4 Hz and could be classified into three ranges: low (up to 12 Hz), medium (12-30) and high frequency (> 30 Hz). SSVEP-based Brain-Computer Interfaces (BCI) are principally focused on the low and medium range of frequencies whereas there are only a few projects in the high-frequency range. However, they only evaluate the performance of different methods to extract SSVEP. This research proposed a high-frequency SSVEP-based asynchronous BCI in order to control the navigation of a mobile object on the screen through a scenario and to reach its final destination. This could help impaired people to navigate a robotic wheelchair. There were three different scenarios with different difficulty levels (easy, medium and difficult). The signal processing method is based on Fourier transform and three EEG measurement channels. The research obtained accuracies ranging in classification from 65% to 100% with Information Transfer Rate varying from 9.4 to 45 bits/min. Our proposed method allows all subjects participating in the study to control the mobile object and to reach a final target without prior training.
Zhong, Zhao-Ming; Zhu, Shi-Yuan; Zhuang, Jing-Shen; Wu, Qian; Chen, Jian-Ting
2016-05-01
Anterior cervical discectomy and fusion is a standard surgical treatment for cervical radiculopathy and myelopathy, but reoperations sometimes are performed to treat complications of fusion such as pseudarthrosis and adjacent-segment degeneration. A cervical disc arthroplasty is designed to preserve motion and avoid the shortcomings of fusion. Available evidence suggests that a cervical disc arthroplasty can provide pain relief and functional improvements similar or superior to an anterior cervical discectomy and fusion. However, there is controversy regarding whether a cervical disc arthroplasty can reduce the frequency of reoperations. We performed a meta-analysis of randomized controlled trials (RCTs) to compare cervical disc arthroplasty with anterior cervical discectomy and fusion regarding (1) the overall frequency of reoperation at the index and adjacent levels; (2) the frequency of reoperation at the index level; and (3) the frequency of reoperation at the adjacent levels. PubMed, EMBASE, and the Cochrane Register of Controlled Trials databases were searched to identify RCTs comparing cervical disc arthroplasty with anterior cervical discectomy and fusion and reporting the frequency of reoperation. We also manually searched the reference lists of articles and reviews for possible relevant studies. Twelve RCTs with a total of 3234 randomized patients were included. Eight types of disc prostheses were used in the included studies. In the anterior cervical discectomy and fusion group, autograft was used in one study and allograft in 11 studies. Nine of 12 studies were industry sponsored. Pooled risk ratio (RR) and associated 95% CI were calculated for the frequency of reoperation using random-effects or fixed-effects models depending on the heterogeneity of the included studies. A funnel plot suggested the possible presence of publication bias in the available pool of studies; that is, the shape of the plot suggests that smaller negative or no-difference studies may have been performed but have not been published, and so were not identified and included in this meta-analysis. The overall frequency of reoperation at the index and adjacent levels was lower in the cervical disc arthroplasty group (6%; 108/1762) than in the anterior cervical discectomy and fusion group (12%; 171/1472) (RR, 0.54; 95% CI, 0.36-0.80; p = 0.002). Subgroup analyses were performed according to secondary surgical level. Compared with anterior cervical discectomy and fusion, cervical disc arthroplasty was associated with fewer reoperations at the index level (RR, 0.50; 95% CI, 0.37-0.68; p < 0.001) and adjacent levels (RR, 0.52; 95% CI, 0.37-0.74; p < 0.001). Cervical disc arthroplasty is associated with fewer reoperations than anterior cervical discectomy and fusion, indicating that it is a safe and effective alternative to fusion for cervical radiculopathy and myelopathy. However, because of some limitations, these findings should be interpreted with caution. Additional studies are needed. Level I, therapeutic study.
Fusion of multi-spectral and panchromatic images based on 2D-PWVD and SSIM
NASA Astrophysics Data System (ADS)
Tan, Dongjie; Liu, Yi; Hou, Ruonan; Xue, Bindang
2016-03-01
A combined method using 2D pseudo Wigner-Ville distribution (2D-PWVD) and structural similarity(SSIM) index is proposed for fusion of low resolution multi-spectral (MS) image and high resolution panchromatic (PAN) image. First, the intensity component of multi-spectral image is extracted with generalized IHS transform. Then, the spectrum diagrams of the intensity components of multi-spectral image and panchromatic image are obtained with 2D-PWVD. Different fusion rules are designed for different frequency information of the spectrum diagrams. SSIM index is used to evaluate the high frequency information of the spectrum diagrams for assigning the weights in the fusion processing adaptively. After the new spectrum diagram is achieved according to the fusion rule, the final fusion image can be obtained by inverse 2D-PWVD and inverse GIHS transform. Experimental results show that, the proposed method can obtain high quality fusion images.
Correlated photometric and polarimetric phenomena in AM Herculis
NASA Technical Reports Server (NTRS)
Priedhorsky, W. C.; Krzeminski, W.; Tapia, S.
1978-01-01
Via simultaneous multicolor photometry and polarimetry of AM Herculis, we find correlations among polarization, flux, and color in the V and I bands in periodic and nonperiodic (i.e., flickering) activity. The primary minimum observed in both bands is accompanied by a blueward shift of the (B - R) color and a decrease in the absolute value of the percent circular polarization in the V band. Outside primary minimum, peaks of flickering activity tend to be associated with an increase in the absolute value of the circular polarization and the concurrent reddening of the (B - R) and (R - I) colors. The visual light curve of AM Her can be explained by a flickering, circularly polarized light source which is obscured at primary minimum, and is redder than the total system color in the URVRI bands.
Discovery of optical flickering from the symbiotic star EF Aquilae
NASA Astrophysics Data System (ADS)
Zamanov, R. K.; Boeva, S.; Nikolov, Y. M.; Petrov, B.; Bachev, R.; Latev, G. Y.; Popov, V. A.; Stoyanov, K. A.; Bode, M. F.; Martí, J.; Tomov, T.; Antonova, A.
2017-07-01
We report optical CCD photometry of the recently identified symbiotic star EF Aql. Our observations in Johnson V and B bands clearly show the presence of stochastic light variations with an amplitude of about 0.2 mag on a time scale of minutes. The observations point toward a white dwarf (WD) as the hot component in the system. It is the 11-th object among more than 200 symbiotic stars known with detected optical flickering. Estimates of the mass accretion rate onto the WD and the mass loss rate in the wind of the Mira secondary star lead to the conclusion that less than 1 per cent of the wind is captured by the WD. Eight further candidates for the detection of flickering in similar systems are suggested.
The inverse problem of estimating the gravitational time dilation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gusev, A. V., E-mail: avg@sai.msu.ru; Litvinov, D. A.; Rudenko, V. N.
2016-11-15
Precise testing of the gravitational time dilation effect suggests comparing the clocks at points with different gravitational potentials. Such a configuration arises when radio frequency standards are installed at orbital and ground stations. The ground-based standard is accessible directly, while the spaceborne one is accessible only via the electromagnetic signal exchange. Reconstructing the current frequency of the spaceborne standard is an ill-posed inverse problem whose solution depends significantly on the characteristics of the stochastic electromagnetic background. The solution for Gaussian noise is known, but the nature of the standards themselves is associated with nonstationary fluctuations of a wide class ofmore » distributions. A solution is proposed for a background of flicker fluctuations with a spectrum (1/f){sup γ}, where 1 < γ < 3, and stationary increments. The results include formulas for the error in reconstructing the frequency of the spaceborne standard and numerical estimates for the accuracy of measuring the relativistic redshift effect.« less
Lighting Quality Affects Eyestrain of Operators at Sorting Station in Beverage Industry
NASA Astrophysics Data System (ADS)
Anizar; Erwin
2017-03-01
This study observes sorters’ performance in two beverage industries whose job is to separate defect products found. Sorters observe bottles quality and beverage quality continuously, therefore requiring more focused eyes which makes eyes’ load heavier. Sorters’ eyestrain causes more defect products pass the selection. In this study, measurement is conducted toward ilumintation, operators’ time response, and defect products that pass the selection. Measurement is hold in 2 beverage industries for four days with four measurements per day, twice in the morning and twice in the afternoon. Ilumination is measured with 4 in 1 environmental meter in grid 1m x 1m, while operators’ time response is measured with Flicker Fusion. Illuminance is generally higher in the morning than in the evening, but still under the standard of Indonesia. Overall, sorters’ time response is higher in the morning than in the afternoon. Higher time response shows that operators experiencing lower fatigue than lower time response. The sorting duration also affects operators’ time response and defect products which pass the selection.
Strömberg, C; Mattila, M J
1987-05-01
Objective and subjective effects on human performance of clovoxamine and mianserin were measured in 12 student volunteers who participated in 12 test sessions and received single doses of clovoxamine 50 mg, 100 mg and 150 mg, mianserin 20 mg, and placebo in a double-blind and cross-over manner. Each test drug was given twice, both in combination with alcohol 0.8 g/kg and with a non-alcoholic drink. The tests included tracking, body balance, flicker fusion, horizontal nystagmus, digit symbol substitution, recall memory, and subjective assessments on visual analogue scales. Mianserin and alcohol impaired objective performance in most tests, and their combination showed at least an additive effect. Alcohol counteracted rather than increased mianserin-induced subjective sedation. Clovoxamine neither differed significantly from placebo nor increased alcohol effects. On the contrary, clovoxamine 150 mg reduced significantly alcohol-induced body sway. No evidence of pharmacokinetic interactions were found between the study drugs and alcohol.
Momeni, Saba; Pourghassem, Hossein
2014-08-01
Recently image fusion has prominent role in medical image processing and is useful to diagnose and treat many diseases. Digital subtraction angiography is one of the most applicable imaging to diagnose brain vascular diseases and radiosurgery of brain. This paper proposes an automatic fuzzy-based multi-temporal fusion algorithm for 2-D digital subtraction angiography images. In this algorithm, for blood vessel map extraction, the valuable frames of brain angiography video are automatically determined to form the digital subtraction angiography images based on a novel definition of vessel dispersion generated by injected contrast material. Our proposed fusion scheme contains different fusion methods for high and low frequency contents based on the coefficient characteristic of wrapping second generation of curvelet transform and a novel content selection strategy. Our proposed content selection strategy is defined based on sample correlation of the curvelet transform coefficients. In our proposed fuzzy-based fusion scheme, the selection of curvelet coefficients are optimized by applying weighted averaging and maximum selection rules for the high frequency coefficients. For low frequency coefficients, the maximum selection rule based on local energy criterion is applied to better visual perception. Our proposed fusion algorithm is evaluated on a perfect brain angiography image dataset consisting of one hundred 2-D internal carotid rotational angiography videos. The obtained results demonstrate the effectiveness and efficiency of our proposed fusion algorithm in comparison with common and basic fusion algorithms.
VCO PLL Frequency Synthesizers for Spacecraft Transponders
NASA Technical Reports Server (NTRS)
Smith, Scott; Mysoor, Narayan; Lux, James; Cook, Brian
2007-01-01
Two documents discuss a breadboard version of advanced transponders that, when fully developed, would be installed on future spacecraft to fly in deep space. These transponders will be required to be capable of operation on any deepspace- communications uplink frequency channel between 7,145 and 7,235 MHz, and any downlink frequency channel between 8,400 and 8,500 MHz. The document focuses on the design and operation of frequency synthesizers for the receiver and transmitter. Heretofore, frequency synthesizers in deep-space transponders have been based on dielectric resonator oscillators (DROs), which do not have the wide tuning bandwidth necessary to tune over all channels in the uplink or downlink frequency bands. To satisfy the requirement for tuning bandwidth, the present frequency synthesizers are based on voltage-controlled-oscillator (VCO) phase-locked loops (PLLs) implemented by use of monolithic microwave integrated circuits (MMICs) implemented using inGaP heterojunction bipolar transistor (HBT) technology. MMIC VCO PLL frequency synthesizers similar to the present ones have been used in commercial and military applications but, until now, have exhibited too much phase noise for use in deep-space transponders. The present frequency synthesizers contain advanced MMIC VCOs, which use HBT technology and have lower levels of flicker (1/f) phase noise. When these MMIC VCOs are used with high-speed MMIC frequency dividers, it becomes possible to obtain the required combination of frequency agility and low phase noise.
NASA Astrophysics Data System (ADS)
Wang, Zhuozheng; Deller, J. R.; Fleet, Blair D.
2016-01-01
Acquired digital images are often corrupted by a lack of camera focus, faulty illumination, or missing data. An algorithm is presented for fusion of multiple corrupted images of a scene using the lifting wavelet transform. The method employs adaptive fusion arithmetic based on matrix completion and self-adaptive regional variance estimation. Characteristics of the wavelet coefficients are used to adaptively select fusion rules. Robust principal component analysis is applied to low-frequency image components, and regional variance estimation is applied to high-frequency components. Experiments reveal that the method is effective for multifocus, visible-light, and infrared image fusion. Compared with traditional algorithms, the new algorithm not only increases the amount of preserved information and clarity but also improves robustness.
Epstein, Nancy E.
2016-01-01
Background: In the lumbar spine, do more nerve root injuries occur utilizing minimally invasive surgery (MIS) techniques versus open lumbar procedures? To answer this question, we compared the frequency of nerve root injuries for multiple open versus MIS operations including diskectomy, laminectomy with/without fusion addressing degenerative disc disease, stenosis, and/or degenerative spondylolisthesis. Methods: Several of Desai et al. large Spine Patient Outcomes Research Trial studies showed the frequency for nerve root injury following an open diskectomy ranged from 0.13% to 0.25%, for open laminectomy/stenosis with/without fusion it was 0%, and for open laminectomy/stenosis/degenerative spondylolisthesis with/without fusion it was 2%. Results: Alternatively, one study compared the incidence of root injuries utilizing MIS transforaminal lumbar interbody fusion (TLIF) versus posterior lumbar interbody fusion (PLIF) techniques; 7.8% of PLIF versus 2% of TLIF patients sustained root injuries. Furthermore, even higher frequencies of radiculitis and nerve root injuries occurred during anterior lumbar interbody fusions (ALIFs) versus extreme lateral interbody fusions (XLIFs). These high frequencies were far from acceptable; 15.8% following ALIF experienced postoperative radiculitis, while 23.8% undergoing XLIF sustained root/plexus deficits. Conclusions: This review indicates that MIS (TLIF/PLIF/ALIF/XLIF) lumbar surgery resulted in a higher incidence of root injuries, radiculitis, or plexopathy versus open lumbar surgical techniques. Furthermore, even a cursory look at the XLIF data demonstrated the greater danger posed to neural tissue by this newest addition to the MIS lumbar surgical armamentariu. The latter should prompt us as spine surgeons to question why the XLIF procedure is still being offered to our patients? PMID:26904372
NASA Technical Reports Server (NTRS)
Chase, W. D.
1975-01-01
The calligraphic chromatic projector described was developed to improve the perceived realism of visual scene simulation ('out-the-window visuals'). The optical arrangement of the projector is illustrated and discussed. The device permits drawing 2000 vectors in as many as 500 colors, all above critical flicker frequencies, and use of high scene resolution and brightness at an acceptable level to the pilot, with the maximum system capabilities of 1000 lines and 1000 fL. The device for generating the colors is discussed, along with an experiment conducted to demonstrate potential improvements in performance and pilot opinion. Current research work and future research plans are noted.
Smollon, William E; Wooten, Billy R; Hammond, Billy R
2015-11-01
Heterochromatic flicker photometry (HFP) is the most common technique of measuring macular pigment optical density (MPOD). Some data strongly suggest that HFP samples MPOD specifically at the edge of center-fixated circular stimuli. Other data have led to the conclusion that HFP samples over the entire area of the stimulus. To resolve this disparity, MPOD was measured using HFP and a series of solid discs of varying radii (0.25 to 2.0 deg) and with thin annuli corresponding to the edge of those discs. MPOD assessed with the two methods yielded excellent correspondence and linearity: Y=0.01+0.98X , r=0.96. A second set of experiments showed that if a disc stimulus is adjusted for no-flicker (the standard procedure) and simply reduced in size, no flicker is observed despite the higher level of MPOD in the smaller area. Taken together, these results confirm that MPOD is determined at the edge of the measuring stimulus when using stimulus sizes in the range that is in dispute (up to a radius of 0.75 deg). The basis for this edge effect can be explained by quantitative differences in the spatial-temporal properties of the visual field as a function of angular distance from the fixation point.
Wang, Shau-Chun; Chen, Hsiao-Ping; Lee, Chia-Yu; Yeo, Leslie Y
2005-04-15
In capillary electrophoresis, effective optical signal quality improvement is obtained when high frequency (>100 Hz) external pulse fields modulate analyte velocities with synchronous lock-in detection. However, the pulse frequency is constrained under a critical value corresponding to the time required for the bulk viscous flow, which arises due to viscous momentum diffusion from the electro-osmotic slip in the Debye layer, to reach steady-state. By solving the momentum diffusion equation for transient bulk flow in the micro-channel, we show that this set-in time to steady-state and hence, the upper limit for the pulse frequency is dependent on the characteristic diffusion length scale and therefore the channel geometry; for cylindrical capillaries, the set-in time is approximately one half of that for rectangular slot channels. From our estimation of the set-in time and hence the upper frequency modulation limit, we propose that the half width of planar channels does not exceed 100 microm and that the radii of cylindrical channels be limited to 140 microm such that there is a finite working bandwidth range above 100 Hz and below the upper limit in order for flicker noise to be effectively suppressed.
Visual orientation by the crown-of-thorns starfish ( Acanthaster planci)
NASA Astrophysics Data System (ADS)
Petie, Ronald; Hall, Michael R.; Hyldahl, Mia; Garm, Anders
2016-12-01
Photoreception in echinoderms has been known for over 200 years, but their visual capabilities remain poorly understood. As has been reported for some asteroids, the crown-of-thorns starfish ( Acanthaster planci) possess a seemingly advanced eye at the tip of each of its 7-23 arms. With such an array of eyes, the starfish can integrate a wide field of view of its surroundings. We hypothesise that, at close range, orientation and directional movements of the crown-of-thorns starfish are visually guided. In this study, the eyes and vision of A. planci were examined by means of light microscopy, electron microscopy, underwater goniometry, electroretinograms and behavioural experiments in the animals' natural habitat. We found that only animals with intact vision could orient to a nearby coral reef, whereas blinded animals, with olfaction intact, walked in random directions. The eye had peak sensitivity in the blue part (470 nm) of the visual spectrum and a narrow, horizontal visual field of approximately 100° wide and 30° high. With approximately 250 ommatidia in each adult compound eye and average interommatidial angles of 8°, crown-of-thorns starfish have the highest spatial resolution of any starfish studied to date. In addition, they have the slowest vision of all animals examined thus far, with a flicker fusion frequency of only 0.6-0.7 Hz. This may be adaptive as fast vision is not required for the detection of stationary objects such as reefs. In short, the eyes seem optimised for detecting large, dark, stationary objects contrasted against an ocean blue background. Our results show that the visual sense of the crown-of-thorns starfish is much more elaborate than has been thus far appreciated and is essential for orientation and localisation of suitable habitats.
Yang, Guocheng; Li, Meiling; Chen, Leiting; Yu, Jie
2015-01-01
We propose a novel medical image fusion scheme based on the statistical dependencies between coefficients in the nonsubsampled contourlet transform (NSCT) domain, in which the probability density function of the NSCT coefficients is concisely fitted using generalized Gaussian density (GGD), as well as the similarity measurement of two subbands is accurately computed by Jensen-Shannon divergence of two GGDs. To preserve more useful information from source images, the new fusion rules are developed to combine the subbands with the varied frequencies. That is, the low frequency subbands are fused by utilizing two activity measures based on the regional standard deviation and Shannon entropy and the high frequency subbands are merged together via weight maps which are determined by the saliency values of pixels. The experimental results demonstrate that the proposed method significantly outperforms the conventional NSCT based medical image fusion approaches in both visual perception and evaluation indices. PMID:26557871
Bhagat, Mayank; Bhushan, Chitresh; Saha, Goutam; Shimjo, Shinsuke; Watanabe, Katsumi; Bhattacharya, Joydeep
2009-01-01
Background Photosensitive epilepsy is a type of reflexive epilepsy triggered by various visual stimuli including colourful ones. Despite the ubiquitous presence of colorful displays, brain responses against different colour combinations are not properly studied. Methodology/Principal Findings Here, we studied the photosensitivity of the human brain against three types of chromatic flickering stimuli by recording neuromagnetic brain responses (magnetoencephalogram, MEG) from nine adult controls, an unmedicated patient, a medicated patient, and two controls age-matched with patients. Dynamical complexities of MEG signals were investigated by a family of wavelet entropies. Wavelet entropy is a newly proposed measure to characterize large scale brain responses, which quantifies the degree of order/disorder associated with a multi-frequency signal response. In particular, we found that as compared to the unmedicated patient, controls showed significantly larger wavelet entropy values. We also found that Renyi entropy is the most powerful feature for the participant classification. Finally, we also demonstrated the effect of combinational chromatic sensitivity on the underlying order/disorder in MEG signals. Conclusions/Significance Our results suggest that when perturbed by potentially epileptic-triggering stimulus, healthy human brain manages to maintain a non-deterministic, possibly nonlinear state, with high degree of disorder, but an epileptic brain represents a highly ordered state which making it prone to hyper-excitation. Further, certain colour combination was found to be more threatening than other combinations. PMID:19779630
Bhagat, Mayank; Bhushan, Chitresh; Saha, Goutam; Shimjo, Shinsuke; Watanabe, Katsumi; Bhattacharya, Joydeep
2009-09-25
Photosensitive epilepsy is a type of reflexive epilepsy triggered by various visual stimuli including colourful ones. Despite the ubiquitous presence of colorful displays, brain responses against different colour combinations are not properly studied. Here, we studied the photosensitivity of the human brain against three types of chromatic flickering stimuli by recording neuromagnetic brain responses (magnetoencephalogram, MEG) from nine adult controls, an unmedicated patient, a medicated patient, and two controls age-matched with patients. Dynamical complexities of MEG signals were investigated by a family of wavelet entropies. Wavelet entropy is a newly proposed measure to characterize large scale brain responses, which quantifies the degree of order/disorder associated with a multi-frequency signal response. In particular, we found that as compared to the unmedicated patient, controls showed significantly larger wavelet entropy values. We also found that Renyi entropy is the most powerful feature for the participant classification. Finally, we also demonstrated the effect of combinational chromatic sensitivity on the underlying order/disorder in MEG signals. Our results suggest that when perturbed by potentially epileptic-triggering stimulus, healthy human brain manages to maintain a non-deterministic, possibly nonlinear state, with high degree of disorder, but an epileptic brain represents a highly ordered state which making it prone to hyper-excitation. Further, certain colour combination was found to be more threatening than other combinations.
Reduction of display artifacts by random sampling
NASA Technical Reports Server (NTRS)
Ahumada, A. J., Jr.; Nagel, D. C.; Watson, A. B.; Yellott, J. I., Jr.
1983-01-01
The application of random-sampling techniques to remove visible artifacts (such as flicker, moire patterns, and paradoxical motion) introduced in TV-type displays by discrete sequential scanning is discussed and demonstrated. Sequential-scanning artifacts are described; the window of visibility defined in spatiotemporal frequency space by Watson and Ahumada (1982 and 1983) and Watson et al. (1983) is explained; the basic principles of random sampling are reviewed and illustrated by the case of the human retina; and it is proposed that the sampling artifacts can be replaced by random noise, which can then be shifted to frequency-space regions outside the window of visibility. Vertical sequential, single-random-sequence, and continuously renewed random-sequence plotting displays generating 128 points at update rates up to 130 Hz are applied to images of stationary and moving lines, and best results are obtained with the single random sequence for the stationary lines and with the renewed random sequence for the moving lines.
NASA Astrophysics Data System (ADS)
Moonon, Altan-Ulzii; Hu, Jianwen; Li, Shutao
2015-12-01
The remote sensing image fusion is an important preprocessing technique in remote sensing image processing. In this paper, a remote sensing image fusion method based on the nonsubsampled shearlet transform (NSST) with sparse representation (SR) is proposed. Firstly, the low resolution multispectral (MS) image is upsampled and color space is transformed from Red-Green-Blue (RGB) to Intensity-Hue-Saturation (IHS). Then, the high resolution panchromatic (PAN) image and intensity component of MS image are decomposed by NSST to high and low frequency coefficients. The low frequency coefficients of PAN and the intensity component are fused by the SR with the learned dictionary. The high frequency coefficients of intensity component and PAN image are fused by local energy based fusion rule. Finally, the fused result is obtained by performing inverse NSST and inverse IHS transform. The experimental results on IKONOS and QuickBird satellites demonstrate that the proposed method provides better spectral quality and superior spatial information in the fused image than other remote sensing image fusion methods both in visual effect and object evaluation.
Green frequency-doubled laser-beam propagation in high-temperature hohlraum plasmas.
Niemann, C; Berger, R L; Divol, L; Froula, D H; Jones, O; Kirkwood, R K; Meezan, N; Moody, J D; Ross, J; Sorce, C; Suter, L J; Glenzer, S H
2008-02-01
We demonstrate propagation and small backscatter losses of a frequency-doubled (2omega) laser beam interacting with inertial confinement fusion hohlraum plasmas. The electron temperature of 3.3 keV, approximately a factor of 2 higher than achieved in previous experiments with open geometry targets, approaches plasma conditions of high-fusion yield hohlraums. In this new temperature regime, we measure 2omega laser-beam transmission approaching 80% with simultaneous backscattering losses of less than 10%. These findings suggest that good laser coupling into fusion hohlraums using 2omega light is possible.
Cryogenic Pound Circuits for Cryogenic Sapphire Oscillators
NASA Technical Reports Server (NTRS)
Dick, G. John; Wang, Rabi
2006-01-01
Two modern cryogenic variants of the Pound circuit have been devised to increase the frequency stability of microwave oscillators that include cryogenic sapphire-filled cavity resonators. The original Pound circuit is a microwave frequency discriminator that provides feedback to stabilize a voltage-controlled microwave oscillator with respect to an associated cavity resonator. In the present cryogenic Pound circuits, the active microwave devices are implemented by use of state-of-the-art commercially available tunnel diodes that exhibit low flicker noise (required for high frequency stability) and function well at low temperatures and at frequencies up to several tens of gigahertz. While tunnel diodes are inherently operable as amplitude detectors and amplitude modulators, they cannot, by themselves, induce significant phase modulation. Therefore, each of the present cryogenic Pound circuits includes passive circuitry that transforms the AM into the required PM. Each circuit also contains an AM detector that is used to sample the microwave signal at the input terminal of the high-Q resonator for the purpose of verifying the desired AM null at this point. Finally, each circuit contains a Pound signal detector that puts out a signal, at the modulation frequency, having an amplitude proportional to the frequency error in the input signal. High frequency stability is obtained by processing this output signal into feedback to a voltage-controlled oscillator to continuously correct the frequency error in the input signal.
Measuring nonlinear signal combination using EEG.
Cunningham, Darren G M; Baker, Daniel H; Peirce, Jonathan W
2017-05-01
Relatively little is known about the processes, both linear and nonlinear, by which signals are combined beyond V1. By presenting two stimulus components simultaneously, flickering at different temporal frequencies (frequency tagging) while measuring steady-state visual evoked potentials, we can assess responses to the individual components, including direct measurements of suppression on each other, and various nonlinear responses to their combination found at intermodulation frequencies. The result is a rather rich dataset of frequencies at which responses can be found. We presented pairs of sinusoidal gratings at different temporal frequencies, forming plaid patterns that were "coherent" (looking like a checkerboard) and "noncoherent" (looking like a pair of transparently overlaid gratings), and found clear intermodulation responses to compound stimuli, indicating nonlinear summation. This might have been attributed to cross-orientation suppression except that the pattern of intermodulation responses differed for coherent and noncoherent patterns, whereas the effects of suppression (measured at the component frequencies) did not. A two-stage model of nonlinear summation involving conjunction detection with a logical AND gate described the data well, capturing the difference between coherent and noncoherent plaids over a wide array of possible response frequencies. Multistimulus frequency-tagged EEG in combination with computational modeling may be a very valuable tool in studying the conjunction of these signals. In the current study the results suggest a second-order mechanism responding selectively to coherent plaid patterns.
A flickering study of nova-like systems KR Aur and UU Aqr
NASA Astrophysics Data System (ADS)
Dobrotka, A.; Mineshige, S.; Casares, J.
2012-03-01
We present a study of the flickering activity in two nova-like systems, KR Aur and UU Aqr. We applied a statistical model of flickering simulations in accretion discs based on turbulent angular momentum transport between two adjacent rings with an exponential distribution of the turbulence dimension scale. The model is based on a steady-state disc model, which is satisfied in the case of hot ionized discs of nova-like cataclysmic variables. Our model successfully fits the observed power-density spectrum of KR Aur with the disc parameter α= 0.10-0.40 and an inner-disc truncation radius in the range Rin= 0.88-1.67 × 109 cm. The exact values depend on the mass-transfer rate in the sense that α decreases and Rin increases with mass-transfer rate. In any case, the inner-disc radius found for KR Aur is considerably smaller than those for quiescent dwarf novae, as predicted by the disc instability model. On the other hand, our simulations fail to reproduce the power-density spectrum of UU Aqr. A tantalizing explanation involves the possible presence of spiral waves, which are expected in UU Aqr because of its low mass ratio but not in KR Aur. In general our model predicts the observed concentration of flickering in the central disc. We explain this by the radial dependence of the angular-momentum gradient.
[Rumination and cognitive fusion in dementia family caregivers].
Romero-Moreno, Rosa; Márquez-González, María; Losada, Andrés; Fernández-Fernández, Virginia; Nogales-González, Celia
2015-01-01
Rumination has been described as a dysfunctional coping strategy related to emotional distress. Recently, it has been highlighted from the Acceptance and Commitment Therapy therapeutic approach, the negative role that cognitive fusion (the extent to which we are psychologically tangled with and dominated by the form or content of our thoughts) has on the explanation of distress. The aim of this study is to simultaneously analyze the role of rumination and cognitive fusion in the caregiving stress process. The sample of 176 dementia caregivers was divided in four groups, taking into account their levels of rumination and cognitive fusion: HRHF=high rumination+high cognitive fusion; HRLF=high rumination+low cognitive fusion; LRHF= low rumination+high cognitive fusion; and LRLC=low rumination and low cognitive fusion. Caregiver stress factors, frequency of pleasant events, experiential avoidance, coherence and satisfaction with personal values, depression, anxiety and satisfaction with life, were measured. The HRHF group showed higher levels of depression, anxiety, experiential avoidance and lower levels of satisfaction with life, frequency of pleasant events, coherence and satisfaction with personal values, than the other three groups. Considering simultaneously rumination and cognitive fusion may contribute to a better understanding of caregiver coping and distress. Copyright © 2014 SEGG. Published by Elsevier Espana. All rights reserved.
Shah, Nameeta; Lankerovich, Michael; Lee, Hwahyung; Yoon, Jae-Geun; Schroeder, Brett; Foltz, Greg
2013-11-22
RNA-seq has spurred important gene fusion discoveries in a number of different cancers, including lung, prostate, breast, brain, thyroid and bladder carcinomas. Gene fusion discovery can potentially lead to the development of novel treatments that target the underlying genetic abnormalities. In this study, we provide comprehensive view of gene fusion landscape in 185 glioblastoma multiforme patients from two independent cohorts. Fusions occur in approximately 30-50% of GBM patient samples. In the Ivy Center cohort of 24 patients, 33% of samples harbored fusions that were validated by qPCR and Sanger sequencing. We were able to identify high-confidence gene fusions from RNA-seq data in 53% of the samples in a TCGA cohort of 161 patients. We identified 13 cases (8%) with fusions retaining a tyrosine kinase domain in the TCGA cohort and one case in the Ivy Center cohort. Ours is the first study to describe recurrent fusions involving non-coding genes. Genomic locations 7p11 and 12q14-15 harbor majority of the fusions. Fusions on 7p11 are formed in focally amplified EGFR locus whereas 12q14-15 fusions are formed by complex genomic rearrangements. All the fusions detected in this study can be further visualized and analyzed using our website: http://ivygap.swedish.org/fusions. Our study highlights the prevalence of gene fusions as one of the major genomic abnormalities in GBM. The majority of the fusions are private fusions, and a minority of these recur with low frequency. A small subset of patients with fusions of receptor tyrosine kinases can benefit from existing FDA approved drugs and drugs available in various clinical trials. Due to the low frequency and rarity of clinically relevant fusions, RNA-seq of GBM patient samples will be a vital tool for the identification of patient-specific fusions that can drive personalized therapy.
A visual parallel-BCI speller based on the time-frequency coding strategy.
Xu, Minpeng; Chen, Long; Zhang, Lixin; Qi, Hongzhi; Ma, Lan; Tang, Jiabei; Wan, Baikun; Ming, Dong
2014-04-01
Spelling is one of the most important issues in brain-computer interface (BCI) research. This paper is to develop a visual parallel-BCI speller system based on the time-frequency coding strategy in which the sub-speller switching among four simultaneously presented sub-spellers and the character selection are identified in a parallel mode. The parallel-BCI speller was constituted by four independent P300+SSVEP-B (P300 plus SSVEP blocking) spellers with different flicker frequencies, thereby all characters had a specific time-frequency code. To verify its effectiveness, 11 subjects were involved in the offline and online spellings. A classification strategy was designed to recognize the target character through jointly using the canonical correlation analysis and stepwise linear discriminant analysis. Online spellings showed that the proposed parallel-BCI speller had a high performance, reaching the highest information transfer rate of 67.4 bit min(-1), with an average of 54.0 bit min(-1) and 43.0 bit min(-1) in the three rounds and five rounds, respectively. The results indicated that the proposed parallel-BCI could be effectively controlled by users with attention shifting fluently among the sub-spellers, and highly improved the BCI spelling performance.
Non-flickering 100 m RGB visible light communication transmission based on a CMOS image sensor.
Chow, Chi-Wai; Shiu, Ruei-Jie; Liu, Yen-Chun; Liu, Yang; Yeh, Chien-Hung
2018-03-19
We demonstrate a non-flickering 100 m long-distance RGB visible light communication (VLC) transmission based on a complementary-metal-oxide-semiconductor (CMOS) camera. Experimental bit-error rate (BER) measurements under different camera ISO values and different transmission distances are evaluated. Here, we also experimentally reveal that the rolling shutter effect- (RSE) based VLC system cannot work at long distance transmission, and the under-sampled modulation- (USM) based VLC system is a good choice.
NASA Astrophysics Data System (ADS)
Qin, Xinqiang; Hu, Gang; Hu, Kai
2018-01-01
The decomposition of multiple source images using bidimensional empirical mode decomposition (BEMD) often produces mismatched bidimensional intrinsic mode functions, either by their number or their frequency, making image fusion difficult. A solution to this problem is proposed using a fixed number of iterations and a union operation in the sifting process. By combining the local regional features of the images, an image fusion method has been developed. First, the source images are decomposed using the proposed BEMD to produce the first intrinsic mode function (IMF) and residue component. Second, for the IMF component, a selection and weighted average strategy based on local area energy is used to obtain a high-frequency fusion component. Third, for the residue component, a selection and weighted average strategy based on local average gray difference is used to obtain a low-frequency fusion component. Finally, the fused image is obtained by applying the inverse BEMD transform. Experimental results show that the proposed algorithm provides superior performance over methods based on wavelet transform, line and column-based EMD, and complex empirical mode decomposition, both in terms of visual quality and objective evaluation criteria.
Feature-Motivated Simplified Adaptive PCNN-Based Medical Image Fusion Algorithm in NSST Domain.
Ganasala, Padma; Kumar, Vinod
2016-02-01
Multimodality medical image fusion plays a vital role in diagnosis, treatment planning, and follow-up studies of various diseases. It provides a composite image containing critical information of source images required for better localization and definition of different organs and lesions. In the state-of-the-art image fusion methods based on nonsubsampled shearlet transform (NSST) and pulse-coupled neural network (PCNN), authors have used normalized coefficient value to motivate the PCNN-processing both low-frequency (LF) and high-frequency (HF) sub-bands. This makes the fused image blurred and decreases its contrast. The main objective of this work is to design an image fusion method that gives the fused image with better contrast, more detail information, and suitable for clinical use. We propose a novel image fusion method utilizing feature-motivated adaptive PCNN in NSST domain for fusion of anatomical images. The basic PCNN model is simplified, and adaptive-linking strength is used. Different features are used to motivate the PCNN-processing LF and HF sub-bands. The proposed method is extended for fusion of functional image with an anatomical image in improved nonlinear intensity hue and saturation (INIHS) color model. Extensive fusion experiments have been performed on CT-MRI and SPECT-MRI datasets. Visual and quantitative analysis of experimental results proved that the proposed method provides satisfactory fusion outcome compared to other image fusion methods.
Generation of fusion protein EGFRvIII-HBcAg and its anti-tumor effect in vivo
Duan, Xiao-yi; Han, Dong-gang; Zhang, Ming-xin; Wang, Jian-sheng
2009-01-01
The epidermal growth factor receptor variant III (EGFRvIII) is the most common variation of EGFR. Because it shows a high frequency in several different types of tumor and has not been detected in normal tissues, it is an ideal target for tumor specific therapy. In this study, we prepared EGFRvIII-HBcAg fusion protein. After immunization with fusion protein, HBcAg or PBS, the titers of antibody in BALB/c mice immunized with fusion protein reached 2.75 × 105. Western blot analysis demonstrated that the fusion protein had specific antigenicity against anti-EGFRvIII antibody. Further observation showed fusion protein induced a high frequency of IFN-γ-secreting lymphocytes. CD4+T cells rather than CD8+T cells were associated with the production of IFN-γ. Using Renca-vIII(+) cell as specific stimulator, we observed remarkable cytotoxic activity in splenocytes from mice immunized with fusion protein. Mice were challenged with Renca-vIII(+) cells after five times immunization. In fusion protein group, three of ten mice failed to develop tumor and all survived at the end of the research. The weight of tumors in fusion protein were obviously lighter than that in other two groups (t = 4.73, P = 0.044;t = 6.89, P = 0.040). These findings demonstrated that EGFRvIII-HBcAg fusion protein triggered protective responses against tumor expressing EGFRvIII. PMID:19788747
Auditory stream segregation with multi-tonal complexes in hearing-impaired listeners
NASA Astrophysics Data System (ADS)
Rogers, Deanna S.; Lentz, Jennifer J.
2004-05-01
The ability to segregate sounds into different streams was investigated in normally hearing and hearing-impaired listeners. Fusion and fission boundaries were measured using 6-tone complexes with tones equally spaced in log frequency. An ABA-ABA- sequence was used in which A represents a multitone complex ranging from either 250-1000 Hz (low-frequency region) or 1000-4000 Hz (high-frequency region). B also represents a multitone complex with same log spacing as A. Multitonal complexes were 100 ms in duration with 20-ms ramps, and- represents a silent interval of 100 ms. To measure the fusion boundary, the first tone of the B stimulus was either 375 Hz (low) or 1500 Hz (high) and shifted downward in frequency with each progressive ABA triplet until the listener pressed a button indicating that a ``galloping'' rhythm was heard. When measuring the fusion boundary, the first tone of the B stimulus was 252 or 1030 Hz and shifted upward with each triplet. Listeners then pressed a button when the ``galloping rhythm ended.'' Data suggest that hearing-impaired subjects have different fission and fusion boundaries than normal-hearing listeners. These data will be discussed in terms of both peripheral and central factors.
The Pivotal Role of the Right Parietal Lobe in Temporal Attention.
Agosta, Sara; Magnago, Denise; Tyler, Sarah; Grossman, Emily; Galante, Emanuela; Ferraro, Francesco; Mazzini, Nunzia; Miceli, Gabriele; Battelli, Lorella
2017-05-01
The visual system is extremely efficient at detecting events across time even at very fast presentation rates; however, discriminating the identity of those events is much slower and requires attention over time, a mechanism with a much coarser resolution [Cavanagh, P., Battelli, L., & Holcombe, A. O. Dynamic attention. In A. C. Nobre & S. Kastner (Eds.), The Oxford handbook of attention (pp. 652-675). Oxford: Oxford University Press, 2013]. Patients affected by right parietal lesion, including the TPJ, are severely impaired in discriminating events across time in both visual fields [Battelli, L., Cavanagh, P., & Thornton, I. M. Perception of biological motion in parietal patients. Neuropsychologia, 41, 1808-1816, 2003]. One way to test this ability is to use a simultaneity judgment task, whereby participants are asked to indicate whether two events occurred simultaneously or not. We psychophysically varied the frequency rate of four flickering disks, and on most of the trials, one disk (either in the left or right visual field) was flickering out-of-phase relative to the others. We asked participants to report whether two left-or-right-presented disks were simultaneous or not. We tested a total of 23 right and left parietal lesion patients in Experiment 1, and only right parietal patients showed impairment in both visual fields while their low-level visual functions were normal. Importantly, to causally link the right TPJ to the relative timing processing, we ran a TMS experiment on healthy participants. Participants underwent three stimulation sessions and performed the same simultaneity judgment task before and after 20 min of low-frequency inhibitory TMS over right TPJ, left TPJ, or early visual area as a control. rTMS over the right TPJ caused a bilateral impairment in the simultaneity judgment task, whereas rTMS over left TPJ or over early visual area did not affect performance. Altogether, our results directly link the right TPJ to the processing of relative time.
Gregori Grgič, Regina; Calore, Enrico; de'Sperati, Claudio
2016-01-01
Whereas overt visuospatial attention is customarily measured with eye tracking, covert attention is assessed by various methods. Here we exploited Steady-State Visual Evoked Potentials (SSVEPs) - the oscillatory responses of the visual cortex to incoming flickering stimuli - to record the movements of covert visuospatial attention in a way operatively similar to eye tracking (attention tracking), which allowed us to compare motion observation and motion extrapolation with and without eye movements. Observers fixated a central dot and covertly tracked a target oscillating horizontally and sinusoidally. In the background, the left and the right halves of the screen flickered at two different frequencies, generating two SSVEPs in occipital regions whose size varied reciprocally as observers attended to the moving target. The two signals were combined into a single quantity that was modulated at the target frequency in a quasi-sinusoidal way, often clearly visible in single trials. The modulation continued almost unchanged when the target was switched off and observers mentally extrapolated its motion in imagery, and also when observers pointed their finger at the moving target during covert tracking, or imagined doing so. The amplitude of modulation during covert tracking was ∼25-30% of that measured when observers followed the target with their eyes. We used 4 electrodes in parieto-occipital areas, but similar results were achieved with a single electrode in Oz. In a second experiment we tested ramp and step motion. During overt tracking, SSVEPs were remarkably accurate, showing both saccadic-like and smooth pursuit-like modulations of cortical responsiveness, although during covert tracking the modulation deteriorated. Covert tracking was better with sinusoidal motion than ramp motion, and better with moving targets than stationary ones. The clear modulation of cortical responsiveness recorded during both overt and covert tracking, identical for motion observation and motion extrapolation, suggests to include covert attention movements in enactive theories of mental imagery. Copyright © 2015 Elsevier Ltd. All rights reserved.
Greinert, Robin; Ripoll, Cristina; Zipprich, Alexander
2018-05-01
Covert hepatic encephalopathy impairs many aspects of quality of life, although its impact on the emotional state has not been evaluated. This study aims to evaluate the impact of covert hepatic encephalopathy on the emotional state and which factors are associated with changes in the emotional state in patients with cirrhosis. This single-center study included all patients with cirrhosis who underwent the portosystemic encephalopathy syndrome (PSE) test, critical flicker frequency, and emotional state assessment with the Eigenschaftswörterliste 60-S in 2011. Covert hepatic encephalopathy was defined by abnormal PSE. Parametric and non-parametric tests were used according to variable distribution. One hundred seventeen patients with cirrhosis were included (median age: 59 [interquartile range: 48 - 67], 32 % female, 74 % alcohol-associated). Seventy patients had covert hepatic encephalopathy (60 %) with a higher MELD (16 [interquartile range: 13 - 21], p = 0.001) and a higher Child-Pugh score (p = 0.003) compared to patients without encephalopathy. Patients with covert encephalopathy felt reduced mental activity (p = 0.004), lower general well-being (p = 0.001), and reduced extraversion (p = 0.021). The scores in the negative domains such as general lethargy (p = 0.031) and anxiousness/depressiveness (p = 0.033) were higher in patients with covert hepatic encephalopathy. There was no correlation between MELD and the emotional state. Patients with 2 pathological tests (critical flicker frequency and PSE) showed the most distinct alterations in the emotional state in the group of patients with covert hepatic encephalopathy. Patients with covert hepatic encephalopathy have an alteration of the emotional state, which is more marked in patients with 2 pathological tests. Interestingly, MELD had no impact on the emotional state. © Georg Thieme Verlag KG Stuttgart · New York.
[Visual representation of natural scenes in flicker changes].
Nakashima, Ryoichi; Yokosawa, Kazuhiko
2010-08-01
Coherence theory in scene perception (Rensink, 2002) assumes the retention of volatile object representations on which attention is not focused. On the other hand, visual memory theory in scene perception (Hollingworth & Henderson, 2002) assumes that robust object representations are retained. In this study, we hypothesized that the difference between these two theories is derived from the difference of the experimental tasks that they are based on. In order to verify this hypothesis, we examined the properties of visual representation by using a change detection and memory task in a flicker paradigm. We measured the representations when participants were instructed to search for a change in a scene, and compared them with the intentional memory representations. The visual representations were retained in visual long-term memory even in the flicker paradigm, and were as robust as the intentional memory representations. However, the results indicate that the representations are unavailable for explicitly localizing a scene change, but are available for answering the recognition test. This suggests that coherence theory and visual memory theory are compatible.
Optical countermeasures against CLOS weapon systems
NASA Astrophysics Data System (ADS)
Toet, Alexander; Benoist, Koen W.; van Lingen, Joost N. J.; Schleijpen, H. Ric M. A.
2013-10-01
There are many weapon systems in which a human operator acquires a target, tracks it and designates it. Optical countermeasures against this type of systems deny the operator the possibility to fulfill this visual task. We describe the different effects that result from stimulation of the human visual system with high intensity (visible) light, and the associated potential operational impact. Of practical use are flash blindness, where an intense flash of light produces a temporary "blind-spot" in (part of) the visual field, flicker distraction, where strong intensity and/or color changes at a discomfortable frequency are produced, and disability glare where a source of light leads to contrast reduction. Hence there are three possibilities to disrupt the visual task of an operator with optical countermeasures such as flares or lasers or a combination of these; namely, by an intense flash of light, by an annoying light flicker or by a glare source. A variety of flares for this purpose is now available or under development: high intensity flash flares, continuous burning flares or strobe flares which have an oscillating intensity. The use of flare arrays seems particularly promising as an optical countermeasure. Lasers are particularly suited to interfere with human vision, because they can easily be varied in intensity, color and size, but they have to be directed at the (human) target, and issues like pointing and eye-safety have to be taken into account. Here we discuss the design issues and the operational impact of optical countermeasures against human operators.
Video stereo-laparoscopy system
NASA Astrophysics Data System (ADS)
Xiang, Yang; Hu, Jiasheng; Jiang, Huilin
2006-01-01
Minimally invasive surgery (MIS) has contributed significantly to patient care by reducing the morbidity associated with more invasive procedures. MIS procedures have become standard treatment for gallbladder disease and some abdominal malignancies. The imaging system has played a major role in the evolving field of minimally invasive surgery (MIS). The image need to have good resolution, large magnification, especially, the image need to have depth cue at the same time the image have no flicker and suit brightness. The video stereo-laparoscopy system can meet the demand of the doctors. This paper introduces the 3d video laparoscopy has those characteristic, field frequency: 100Hz, the depth space: 150mm, resolution: 10pl/mm. The work principle of the system is introduced in detail, and the optical system and time-division stereo-display system are described briefly in this paper. The system has focusing image lens, it can image on the CCD chip, the optical signal can change the video signal, and through A/D switch of the image processing system become the digital signal, then display the polarized image on the screen of the monitor through the liquid crystal shutters. The doctors with the polarized glasses can watch the 3D image without flicker of the tissue or organ. The 3D video laparoscope system has apply in the MIS field and praised by doctors. Contrast to the traditional 2D video laparoscopy system, it has some merit such as reducing the time of surgery, reducing the problem of surgery and the trained time.
Automated target classification in high resolution dual frequency sonar imagery
NASA Astrophysics Data System (ADS)
Aridgides, Tom; Fernández, Manuel
2007-04-01
An improved computer-aided-detection / computer-aided-classification (CAD/CAC) processing string has been developed. The classified objects of 2 distinct strings are fused using the classification confidence values and their expansions as features, and using "summing" or log-likelihood-ratio-test (LLRT) based fusion rules. The utility of the overall processing strings and their fusion was demonstrated with new high-resolution dual frequency sonar imagery. Three significant fusion algorithm improvements were made. First, a nonlinear 2nd order (Volterra) feature LLRT fusion algorithm was developed. Second, a Box-Cox nonlinear feature LLRT fusion algorithm was developed. The Box-Cox transformation consists of raising the features to a to-be-determined power. Third, a repeated application of a subset feature selection / feature orthogonalization / Volterra feature LLRT fusion block was utilized. It was shown that cascaded Volterra feature LLRT fusion of the CAD/CAC processing strings outperforms summing, baseline single-stage Volterra and Box-Cox feature LLRT algorithms, yielding significant improvements over the best single CAD/CAC processing string results, and providing the capability to correctly call the majority of targets while maintaining a very low false alarm rate. Additionally, the robustness of cascaded Volterra feature fusion was demonstrated, by showing that the algorithm yields similar performance with the training and test sets.
Multi-scale pixel-based image fusion using multivariate empirical mode decomposition.
Rehman, Naveed ur; Ehsan, Shoaib; Abdullah, Syed Muhammad Umer; Akhtar, Muhammad Jehanzaib; Mandic, Danilo P; McDonald-Maier, Klaus D
2015-05-08
A novel scheme to perform the fusion of multiple images using the multivariate empirical mode decomposition (MEMD) algorithm is proposed. Standard multi-scale fusion techniques make a priori assumptions regarding input data, whereas standard univariate empirical mode decomposition (EMD)-based fusion techniques suffer from inherent mode mixing and mode misalignment issues, characterized respectively by either a single intrinsic mode function (IMF) containing multiple scales or the same indexed IMFs corresponding to multiple input images carrying different frequency information. We show that MEMD overcomes these problems by being fully data adaptive and by aligning common frequency scales from multiple channels, thus enabling their comparison at a pixel level and subsequent fusion at multiple data scales. We then demonstrate the potential of the proposed scheme on a large dataset of real-world multi-exposure and multi-focus images and compare the results against those obtained from standard fusion algorithms, including the principal component analysis (PCA), discrete wavelet transform (DWT) and non-subsampled contourlet transform (NCT). A variety of image fusion quality measures are employed for the objective evaluation of the proposed method. We also report the results of a hypothesis testing approach on our large image dataset to identify statistically-significant performance differences.
Multi-Scale Pixel-Based Image Fusion Using Multivariate Empirical Mode Decomposition
Rehman, Naveed ur; Ehsan, Shoaib; Abdullah, Syed Muhammad Umer; Akhtar, Muhammad Jehanzaib; Mandic, Danilo P.; McDonald-Maier, Klaus D.
2015-01-01
A novel scheme to perform the fusion of multiple images using the multivariate empirical mode decomposition (MEMD) algorithm is proposed. Standard multi-scale fusion techniques make a priori assumptions regarding input data, whereas standard univariate empirical mode decomposition (EMD)-based fusion techniques suffer from inherent mode mixing and mode misalignment issues, characterized respectively by either a single intrinsic mode function (IMF) containing multiple scales or the same indexed IMFs corresponding to multiple input images carrying different frequency information. We show that MEMD overcomes these problems by being fully data adaptive and by aligning common frequency scales from multiple channels, thus enabling their comparison at a pixel level and subsequent fusion at multiple data scales. We then demonstrate the potential of the proposed scheme on a large dataset of real-world multi-exposure and multi-focus images and compare the results against those obtained from standard fusion algorithms, including the principal component analysis (PCA), discrete wavelet transform (DWT) and non-subsampled contourlet transform (NCT). A variety of image fusion quality measures are employed for the objective evaluation of the proposed method. We also report the results of a hypothesis testing approach on our large image dataset to identify statistically-significant performance differences. PMID:26007714
Infrared and visible image fusion scheme based on NSCT and low-level visual features
NASA Astrophysics Data System (ADS)
Li, Huafeng; Qiu, Hongmei; Yu, Zhengtao; Zhang, Yafei
2016-05-01
Multi-scale transform (MST) is an efficient tool for image fusion. Recently, many fusion methods have been developed based on different MSTs, and they have shown potential application in many fields. In this paper, we propose an effective infrared and visible image fusion scheme in nonsubsampled contourlet transform (NSCT) domain, in which the NSCT is firstly employed to decompose each of the source images into a series of high frequency subbands and one low frequency subband. To improve the fusion performance we designed two new activity measures for fusion of the lowpass subbands and the highpass subbands. These measures are developed based on the fact that the human visual system (HVS) percept the image quality mainly according to its some low-level features. Then, the selection principles of different subbands are presented based on the corresponding activity measures. Finally, the merged subbands are constructed according to the selection principles, and the final fused image is produced by applying the inverse NSCT on these merged subbands. Experimental results demonstrate the effectiveness and superiority of the proposed method over the state-of-the-art fusion methods in terms of both visual effect and objective evaluation results.
Wang, Ying; Wang, Shumin; Xu, Shiguang; Qu, Jiaqi; Liu, Bo
2014-01-01
The frequencies of EML4-ALK fusion gene in non-small cell lung cancer (NSCLC) with different clinicopathologic features described by previous studies are inconsistent. The key demographic and pathologic features associated with EML4-ALK fusion gene have not been definitively established. This meta-analysis was conducted to compare the frequency of the EML4-ALK fusion gene in patients with different clinicopathologic features and to identify an enriched population of patients with NSCLC harboring EML4-ALK fusion gene. The Pubmed and Embase databases for all studies on EML4-ALK fusion gene in NSCLC patients were searched up to July 2014. A criteria list and exclusion criteria were established to screen the studies. The frequency of the EML4-ALK fusion gene and the clinicopathologic features, including smoking status, pathologic type, gender, and EGFR status were abstracted. Seventeen articles consisting of 4511 NSCLC cases were included in this meta-analysis. A significant lower EML4-ALK fusion gene positive rate was associated with smokers (pooled OR = 0.40, 95% CI = 0.30-0.54, P<0.00001). A significantly higher EML4-ALK fusion gene positivity rate was associated with adenocarcinomas (pooled OR = 2.53, 95% CI = 1.66-3.86, P<0.0001) and female (pooled OR = 0.61, 95% CI = 0.41-0.90, P = 0.01). We found that a significantly lower EML4-ALK fusion gene positivity rate was associated with EGFR mutation (pooled OR = 0.07, 95% CI = 0.03-0.19, P<0.00001). No publication bias was observed in any meta-analysis (all P value of Egger's test >0.05); however, because of the small sample size, no results were in the meta-analysis regarding EGFR gene status. This meta-analysis revealed that the EML4-ALK fusion gene is highly correlated with a never/light smoking history, female and the pathologic type of adenocarcinoma, and is largely mutually exclusive of EGFR.
Wang, Shumin; Xu, Shiguang; Qu, Jiaqi
2014-01-01
Background The frequencies of EML4-ALK fusion gene in non-small cell lung cancer (NSCLC) with different clinicopathologic features described by previous studies are inconsistent. The key demographic and pathologic features associated with EML4-ALK fusion gene have not been definitively established. This meta-analysis was conducted to compare the frequency of the EML4-ALK fusion gene in patients with different clinicopathologic features and to identify an enriched population of patients with NSCLC harboring EML4-ALK fusion gene. Methods The Pubmed and Embase databases for all studies on EML4-ALK fusion gene in NSCLC patients were searched up to July 2014. A criteria list and exclusion criteria were established to screen the studies. The frequency of the EML4-ALK fusion gene and the clinicopathologic features, including smoking status, pathologic type, gender, and EGFR status were abstracted. Results Seventeen articles consisting of 4511 NSCLC cases were included in this meta-analysis. A significant lower EML4-ALK fusion gene positive rate was associated with smokers (pooled OR = 0.40, 95% CI = 0.30–0.54, P<0.00001). A significantly higher EML4-ALK fusion gene positivity rate was associated with adenocarcinomas (pooled OR = 2.53, 95% CI = 1.66–3.86, P<0.0001) and female (pooled OR = 0.61, 95% CI = 0.41–0.90, P = 0.01). We found that a significantly lower EML4-ALK fusion gene positivity rate was associated with EGFR mutation (pooled OR = 0.07, 95% CI = 0.03–0.19, P<0.00001). No publication bias was observed in any meta-analysis (all P value of Egger's test >0.05); however, because of the small sample size, no results were in the meta-analysis regarding EGFR gene status. Conclusion This meta-analysis revealed that the EML4-ALK fusion gene is highly correlated with a never/light smoking history, female and the pathologic type of adenocarcinoma, and is largely mutually exclusive of EGFR. PMID:25360721
Bidau, C J; Giménez, M D; Palmer, C L; Searle, J B
2001-09-01
Chiasma frequency and distribution were studied in male Mus musculus domesticus from the John O'Groats-standard chromosomal hybrid zone in northern Scotland. Individuals of the John O'Groats race (2n=32; homozygous for the Robertsonian fusions 4.10, 6.13, 9.12 and 11.14) and the standard race (2n=40, all telocentric), and hybrids with various karyotypes, were examined. Chiasma frequency was significantly negatively correlated with the number of Robertsonian configurations in the meiotic cell. The decrease of chiasma frequency can be attributed to intrachromosomal effects that reduce the number of chiasmata in Robertsonian bivalents (formed in homozygotes for Robertsonian fusions) and trivalents (formed in heterozygotes). However, the reduction is more pronounced in Robertsonian bivalents and is related to a shift of chiasmata to the distal ends of the chromosome arms. A different type of repatterning occurs in trivalents where there is a significant increase in proximal and interstitial chiasmata.
[A new hypothesis for the treatment of amblyopia: the flicker stimulator].
Parrozzani, A; Fedriga, P; Ferrari, E; De Vincentiis, L
1984-01-01
A variety of cells are involved in the pathogenesis of amblyopia : ON, OFF, ON-OFF cells, postsynaptic cells, neurons of striate cortex and the select interest of the macula. The need for stimulation of these cells in treating amblyopia forms the theoretical basis of the Flicker stimulator with red monochromatic light (LED, 655 nm). The authors present a clinical investigation on 35 subjects with anisometropic or strabismic amblyopia, before extensive treatment with classic anti-amblyopic techniques without satisfactory improvement obtaining significant statistical results (p less than 0,001).
High speed line-scan confocal imaging of stimulus-evoked intrinsic optical signals in the retina
Li, Yang-Guo; Liu, Lei; Amthor, Franklin; Yao, Xin-Cheng
2010-01-01
A rapid line-scan confocal imager was developed for functional imaging of the retina. In this imager, an acousto-optic deflector (AOD) was employed to produce mechanical vibration- and inertia-free light scanning, and a high-speed (68,000 Hz) linear CCD camera was used to achieve sub-cellular and sub-millisecond spatiotemporal resolution imaging. Two imaging modalities, i.e., frame-by-frame and line-by-line recording, were validated for reflected light detection of intrinsic optical signals (IOSs) in visible light stimulus activated frog retinas. Experimental results indicated that fast IOSs were tightly correlated with retinal stimuli, and could track visible light flicker stimulus frequency up to at least 2 Hz. PMID:20125743
New structures of power density spectra for four Kepler active galactic nuclei
NASA Astrophysics Data System (ADS)
Dobrotka, A.; Antonuccio-Delogu, V.; Bajčičáková, I.
2017-09-01
Many nearby active galactic nuclei display a significant short-term variability. In this work, we reanalyse photometric data of four active galactic nuclei observed by Kepler in order to study the flickering activity, with our main goal to search for multiple components in the power density spectra. We find that all four objects have similar characteristics, with two break frequencies at approximately log( f /Hz) = -5.2 and -4.7. We consider some physical phenomena whose characteristic time-scales are consistent with those observed, in particular mass accretion fluctuations in the inner geometrically thick disc (hot X-ray corona) and unstable relativistic Rayleigh-Taylor modes. The former is supported by detection of the same break frequencies in the Swift X-ray data of ZW229-15. We also discuss rms-flux relations, and we detect a possible typical linear trend at lower flux levels. Our findings support the hypothesis of a multiplicative character of variability, in agreement with the propagating accretion fluctuation model.
Gamma frequency entrainment attenuates amyloid load and modifies microglia
Iaccarino, Hannah F.; Singer, Annabelle C.; Martorell, Anthony J.; Rudenko, Andrii; Gao, Fan; Gillingham, Tyler Z.; Mathys, Hansruedi; Seo, Jinsoo; Kritskiy, Oleg; Abdurrob, Fatema; Adaikkan, Chinnakkaruppan; Canter, Rebecca G.; Rueda, Richard; Brown, Emery N.; Boyden, Edward S.; Tsai, Li-Huei
2017-01-01
Changes in gamma oscillations (20-50 Hz) have been observed in several neurological disorders. However, the relationship between gamma and cellular pathologies is unclear. Here, we show reduced behaviorally-driven gamma before the onset of plaque formation or cognitive decline in a mouse model of Alzheimer's disease (AD). Optogenetically driving FS-PV-interneurons at gamma (40 Hz), but not other frequencies, reduced levels of amyloid-β (A β)1-40 and A β1-42 isoforms. Gene expression profiling revealed induction of genes associated with morphological transformation of microglia and histological analysis confirmed increased microglia co-localization with A β. Subsequently, we designed a non-invasive 40 Hz light-flickering paradigm that reduced A β1-40 and A β1-42 levels in visual cortex of pre-depositing mice and mitigated plaque load in aged, depositing mice. Our findings uncover a previously unappreciated function of gamma rhythms in recruiting both neuronal and glial responses to attenuate AD-associated pathology. PMID:27929004
Impaired temporal contrast sensitivity in dyslexics is specific to retain-and-compare paradigms.
Ben-Yehudah, G; Sackett, E; Malchi-Ginzberg, L; Ahissar, M
2001-07-01
Developmental dyslexia is a specific reading disability that affects 5-10% of the population. Recent studies have suggested that dyslexics may experience a deficit in the visual magnocellular pathway. The most extensively studied prediction deriving from this hypothesis is impaired contrast sensitivity to transient, low-luminance stimuli at low spatial frequencies. However, the findings are inconsistent across studies and even seemingly contradictory. In the present study, we administered several different paradigms for assessing temporal contrast sensitivity, and found both impaired and normal contrast sensitivity within the same group of dyslexic participants. Under sequential presentation, in a temporal forced choice paradigm, dyslexics showed impaired sensitivity to both drifting and flickering gratings. However, under simultaneous presentation, with a spatial forced choice paradigm, dyslexics' sensitivity did not differ from that of the controls. Within each paradigm, dyslexics' sensitivity was poorer at higher temporal frequencies, consistent with the magnocellular hypothesis. These results suggest that a basic perceptual impairment in dyslexics may be their limited ability to retain-and-compare perceptual traces across brief intervals.
Chords and harmonies in mixed optical and acoustical stimuli
NASA Astrophysics Data System (ADS)
Hahlweg, Cornelius; Dannenberg, Florian; Dörfler, Joachim; Weber, Bernhard; Weyer, Cornelia; Gercke-Hahn, Harald; Freimuth, Steffen; Heucke, Sören; Gutzmann, Holger Ludwig
2014-09-01
The paper is a follow up of the work presented in last year's Optics and Music session on the perception of coherence between low frequency power modulated light and periodical acoustic stimuli. The composition of chords and harmonies from power modulated light sources and their effect as stand-alone stimulus and in conjunction with the equivalent acoustic signal is discussed. Of special interest here is the modulation near perceptible flicker frequency. The substitution of acoustical chord components by their optical counterpart and vice versa is investigated. Further, concepts of a training application for trombone players and other instrumentalists are presented: since the mean slide of the trombone does not have fixed positions, the note must be found and two players might influence each other. The possibility of helping them to synchronize by optical stimuli derived from their playing is investigated. Beside possible applications in emotional reinforcing multimedia oriented entertainment and training support for musicians, again implications for occupational medicine are discussed.
Thought-action fusion as a causal factor in the development of intrusions.
Rassin, E; Merckelbach, H; Muris, P; Spaan, V
1999-03-01
Thought-action fusion refers to the tendency to treat thoughts and actions as equivalents. Some authors (e.g., Rachman, 1997; Behaviour Research and Therapy, 35, 793-802) have suggested that thought-action fusion plays a role in the etiology of obsessive intrusions. The present study sought to test this idea. Subjects (n = 19) in the experimental condition underwent a bogus EEG recording session. They were informed that the apparatus was able to pick up the word 'apple' and that thoughts of that word could result in the administration of electrical shocks to another person. After having spent 15 minutes in the EEG laboratory, experimental subjects and controls (n = 26) completed a short questionnaire containing items about characteristics of the target thought (e.g., frequency, aversiveness). Results indicate that thought-action fusion, indeed, promotes intrusive thinking in that it results in a higher frequency of target thoughts, more discomfort, and more resistance. Thus, the current findings support the idea that thought-action fusion may contribute to the development of obsessive intrusions.
Tyrosine kinase fusion genes in pediatric BCR-ABL1-like acute lymphoblastic leukemia
Boer, Judith M.; Steeghs, Elisabeth M.P.; Marchante, João R.M.; Boeree, Aurélie; Beaudoin, James J.; Berna Beverloo, H.; Kuiper, Roland P.; Escherich, Gabriele; van der Velden, Vincent H.J.; van der Schoot, C. Ellen; de Groot-Kruseman, Hester A.; Pieters, Rob; den Boer, Monique L.
2017-01-01
Approximately 15% of pediatric B cell precursor acute lymphoblastic leukemia (BCP-ALL) is characterized by gene expression similar to that of BCR-ABL1-positive disease and unfavorable prognosis. This BCR-ABL1-like subtype shows a high frequency of B-cell development gene aberrations and tyrosine kinase-activating lesions. To evaluate the clinical significance of tyrosine kinase gene fusions in children with BCP-ALL, we studied the frequency of recently identified tyrosine kinase fusions, associated genetic features, and prognosis in a representative Dutch/German cohort. We identified 14 tyrosine kinase fusions among 77 BCR-ABL1-like cases (18%) and none among 76 non-BCR-ABL1-like B-other cases. Novel exon fusions were identified for RCSD1-ABL2 and TERF2-JAK2. JAK2 mutation was mutually exclusive with tyrosine kinase fusions and only occurred in cases with high CRLF2 expression. The non/late response rate and levels of minimal residual disease in the fusion-positive BCR-ABL1-like group were higher than in the non-BCR-ABL1-like B-others (p<0.01), and also higher, albeit not statistically significant, compared with the fusion-negative BCR-ABL1-like group. The 8-year cumulative incidence of relapse in the fusion-positive BCR-ABL1-like group (35%) was comparable with that in the fusion-negative BCR-ABL1-like group (35%), and worse than in the non-BCR-ABL1-like B-other group (17%, p=0.07). IKZF1 deletions, predominantly other than the dominant-negative isoform and full deletion, co-occurred with tyrosine kinase fusions. This study shows that tyrosine kinase fusion-positive cases are a high-risk subtype of BCP-ALL, which warrants further studies with specific kinase inhibitors to improve outcome. PMID:27894077
Effect of higher frequency on the classification of steady-state visual evoked potentials
NASA Astrophysics Data System (ADS)
Won, Dong-Ok; Hwang, Han-Jeong; Dähne, Sven; Müller, Klaus-Robert; Lee, Seong-Whan
2016-02-01
Objective. Most existing brain-computer interface (BCI) designs based on steady-state visual evoked potentials (SSVEPs) primarily use low frequency visual stimuli (e.g., <20 Hz) to elicit relatively high SSVEP amplitudes. While low frequency stimuli could evoke photosensitivity-based epileptic seizures, high frequency stimuli generally show less visual fatigue and no stimulus-related seizures. The fundamental objective of this study was to investigate the effect of stimulation frequency and duty-cycle on the usability of an SSVEP-based BCI system. Approach. We developed an SSVEP-based BCI speller using multiple LEDs flickering with low frequencies (6-14.9 Hz) with a duty-cycle of 50%, or higher frequencies (26-34.7 Hz) with duty-cycles of 50%, 60%, and 70%. The four different experimental conditions were tested with 26 subjects in order to investigate the impact of stimulation frequency and duty-cycle on performance and visual fatigue, and evaluated with a questionnaire survey. Resting state alpha powers were utilized to interpret our results from the neurophysiological point of view. Main results. The stimulation method employing higher frequencies not only showed less visual fatigue, but it also showed higher and more stable classification performance compared to that employing relatively lower frequencies. Different duty-cycles in the higher frequency stimulation conditions did not significantly affect visual fatigue, but a duty-cycle of 50% was a better choice with respect to performance. The performance of the higher frequency stimulation method was also less susceptible to resting state alpha powers, while that of the lower frequency stimulation method was negatively correlated with alpha powers. Significance. These results suggest that the use of higher frequency visual stimuli is more beneficial for performance improvement and stability as time passes when developing practical SSVEP-based BCI applications.
Effect of higher frequency on the classification of steady-state visual evoked potentials.
Won, Dong-Ok; Hwang, Han-Jeong; Dähne, Sven; Müller, Klaus-Robert; Lee, Seong-Whan
2016-02-01
Most existing brain-computer interface (BCI) designs based on steady-state visual evoked potentials (SSVEPs) primarily use low frequency visual stimuli (e.g., <20 Hz) to elicit relatively high SSVEP amplitudes. While low frequency stimuli could evoke photosensitivity-based epileptic seizures, high frequency stimuli generally show less visual fatigue and no stimulus-related seizures. The fundamental objective of this study was to investigate the effect of stimulation frequency and duty-cycle on the usability of an SSVEP-based BCI system. We developed an SSVEP-based BCI speller using multiple LEDs flickering with low frequencies (6-14.9 Hz) with a duty-cycle of 50%, or higher frequencies (26-34.7 Hz) with duty-cycles of 50%, 60%, and 70%. The four different experimental conditions were tested with 26 subjects in order to investigate the impact of stimulation frequency and duty-cycle on performance and visual fatigue, and evaluated with a questionnaire survey. Resting state alpha powers were utilized to interpret our results from the neurophysiological point of view. The stimulation method employing higher frequencies not only showed less visual fatigue, but it also showed higher and more stable classification performance compared to that employing relatively lower frequencies. Different duty-cycles in the higher frequency stimulation conditions did not significantly affect visual fatigue, but a duty-cycle of 50% was a better choice with respect to performance. The performance of the higher frequency stimulation method was also less susceptible to resting state alpha powers, while that of the lower frequency stimulation method was negatively correlated with alpha powers. These results suggest that the use of higher frequency visual stimuli is more beneficial for performance improvement and stability as time passes when developing practical SSVEP-based BCI applications.
Sato, Naoyuki
2013-01-01
Theta band power (4-8 Hz) in the scalp electroencephalogram (EEG) is thought to be stronger during memory encoding for subsequently remembered items than for forgotten items. According to simultaneous EEG-functional magnetic resonance imaging (fMRI) measurements, the memory-dependent EEG theta is associated with multiple regions of the brain. This suggests that the multiple regions cooperate with EEG theta synchronization during successful memory encoding. However, a question still remains: What kind of neural dynamic organizes such a memory-dependent global network? In this study, the modulation of the EEG theta entrainment property during successful encoding was hypothesized to lead to EEG theta synchronization among a distributed network. Then, a transient response of EEG theta to a theta-band photic flicker with a short duration was evaluated during memory encoding. In the results, flicker-induced EEG power increased and decreased with a time constant of several hundred milliseconds following the onset and the offset of the flicker, respectively. Importantly, the offset response of EEG power was found to be significantly decreased during successful encoding. Moreover, the offset response of the phase locking index was also found to associate with memory performance. According to computational simulations, the results are interpreted as a smaller time constant (i.e., faster response) of a driven harmonic oscillator rather than a change in the spontaneous oscillatory input. This suggests that the fast response of EEG theta forms a global EEG theta network among memory-related regions during successful encoding, and it contributes to a flexible formation of the network along the time course.
Ca2+ block and flickering both contribute to the negative slope of the IV curve in BK channels.
Schroeder, Indra; Thiel, Gerhard; Hansen, Ulf-Peter
2013-04-01
Single-channel current-voltage (IV) curves of human large-conductance, voltage- and Ca(2+)-activated K(+) (BK) channels are quite linear in 150 mM KCl. In the presence of Ca(2+) and/or Mg(2+), they show a negative slope conductance at high positive potentials. This is generally explained by a Ca(2+)/Mg(2+) block as by Geng et al. (2013. J. Gen. Physiol. http://dx.doi.org/10.1085/jgp.201210955) in this issue. Here, we basically support this finding but add a refinement: the analysis of the open-channel noise by means of β distributions reveals what would be found if measurements were done with an amplifier of sufficient temporal resolution (10 MHz), namely that the block by 2.5 mM Ca(2+) and 2.5 mM Mg(2+) per se would only cause a saturating curve up to +160 mV. Further bending down requires the involvement of a second process related to flickering in the microsecond range. This flickering is hardly affected by the presence or absence of Ca(2+)/Mg(2+). In contrast to the experiments reported here, previous experiments in BK channels (Schroeder and Hansen. 2007. J. Gen. Physiol. http://dx.doi.org/10.1085/jgp.200709802) showed saturating IV curves already in the absence of Ca(2+)/Mg(2+). The reason for this discrepancy could not be identified so far. However, the flickering component was very similar in the old and new experiments, regardless of the occurrence of noncanonical IV curves.
Current drive at plasma densities required for thermonuclear reactors.
Cesario, R; Amicucci, L; Cardinali, A; Castaldo, C; Marinucci, M; Panaccione, L; Santini, F; Tudisco, O; Apicella, M L; Calabrò, G; Cianfarani, C; Frigione, D; Galli, A; Mazzitelli, G; Mazzotta, C; Pericoli, V; Schettini, G; Tuccillo, A A
2010-08-10
Progress in thermonuclear fusion energy research based on deuterium plasmas magnetically confined in toroidal tokamak devices requires the development of efficient current drive methods. Previous experiments have shown that plasma current can be driven effectively by externally launched radio frequency power coupled to lower hybrid plasma waves. However, at the high plasma densities required for fusion power plants, the coupled radio frequency power does not penetrate into the plasma core, possibly because of strong wave interactions with the plasma edge. Here we show experiments performed on FTU (Frascati Tokamak Upgrade) based on theoretical predictions that nonlinear interactions diminish when the peripheral plasma electron temperature is high, allowing significant wave penetration at high density. The results show that the coupled radio frequency power can penetrate into high-density plasmas due to weaker plasma edge effects, thus extending the effective range of lower hybrid current drive towards the domain relevant for fusion reactors.
Dynamical predictors of an imminent phenotypic switch in bacteria
NASA Astrophysics Data System (ADS)
Wang, Huijing; Ray, J. Christian J.
2017-08-01
Single cells can stochastically switch across thresholds imposed by regulatory networks. Such thresholds can act as a tipping point, drastically changing global phenotypic states. In ecology and economics, imminent transitions across such tipping points can be predicted using dynamical early warning indicators. A typical example is ‘flickering’ of a fast variable, predicting a longer-lasting switch from a low to a high state or vice versa. Considering the different timescales between metabolite and protein fluctuations in bacteria, we hypothesized that metabolic early warning indicators predict imminent transitions across a network threshold caused by enzyme saturation. We used stochastic simulations to determine if flickering predicts phenotypic transitions, accounting for a variety of molecular physiological parameters, including enzyme affinity, burstiness of enzyme gene expression, homeostatic feedback, and rates of metabolic precursor influx. In most cases, we found that metabolic flickering rates are robustly peaked near the enzyme saturation threshold. The degree of fluctuation was amplified by product inhibition of the enzyme. We conclude that sensitivity to flickering in fast variables may be a possible natural or synthetic strategy to prepare physiological states for an imminent transition.
a Theoretical and Experimental Investigation of 1/F Noise in the Alpha Decay Rates of AMERICIUM-241.
NASA Astrophysics Data System (ADS)
Pepper, Gary T.
New experimental methods and data analysis techniques were used to investigate the hypothesis of the existence of 1/f noise in a alpha particle emission rates for ^{241}Am. Experimental estimates of the flicker floor were found to be almost two orders of magnitude less than Handel's theoretical prediction and previous measurements. The existence of a flicker floor for ^{57}Co decay, a process for which no charged particles are emitted, indicate that instrumental instability is likely responsible for the values of the flicker floor obtained. The experimental results and the theoretical arguments presented indicate that a re-examination of Handel's theory of 1/f noise is appropriate. Methods of numerical simulation of noise processes with a 1/f^{rm n} power spectral density were developed. These were used to investigate various statistical aspects of 1/f ^{rm n} noise. The probability density function for the Allan variance was investigated in order to establish confidence limits for the observations made. The effect of using grouped (correlated) data, for evaluating the Allan variance, was also investigated.
Multi-Focus Image Fusion Based on NSCT and NSST
NASA Astrophysics Data System (ADS)
Moonon, Altan-Ulzii; Hu, Jianwen
2015-12-01
In this paper, a multi-focus image fusion algorithm based on the nonsubsampled contourlet transform (NSCT) and the nonsubsampled shearlet transform (NSST) is proposed. The source images are first decomposed by the NSCT and NSST into low frequency coefficients and high frequency coefficients. Then, the average method is used to fuse low frequency coefficient of the NSCT. To obtain more accurate salience measurement, the high frequency coefficients of the NSST and NSCT are combined to measure salience. The high frequency coefficients of the NSCT with larger salience are selected as fused high frequency coefficients. Finally, the fused image is reconstructed by the inverse NSCT. We adopt three metrics (Q AB/F , Q e and Q w ) to evaluate the quality of fused images. The experimental results demonstrate that the proposed method outperforms other methods. It retains highly detailed edges and contours.
Separate channels for the analysis of the shape and the movement of moving visual stimulus.
Tolhurst, D J
1973-06-01
1. The effects of temporal modulation on the properties of spatial frequency channels have been investigated using adaptation.2. Adapting to drifting sinusoidal gratings caused threshold elevation that was both spatial frequency and direction specific. Little systematic difference was found between the band widths of the elevation curves for drifting and stationary gratings.3. It was confirmed that adaptation fails to reveal channels at low spatial frequencies when stationary gratings are used. However, channels were revealed at frequencies at least as low as 0.66 c/deg when the test gratings were made to move. These channels are adapted only a little by stationary gratings, confirming their dependence on movement.4. The existence of movement-sensitive channels at low spatial frequencies explains the well known observation that temporal modulation greatly increases the sensitivity of the visual system to low spatial frequencies.5. Temporal modulation was effective at revealing these channels only when the flicker or movement of the test patterns was apparent to the observer; only at low spatial frequencies did patterns, modulated at low rates, actually appear to be temporarily modulated at threshold. At higher spatial frequencies, they were indistinguishable from stationary patterns until the contrast was some way above the detection threshold.6. It is suggested, therefore, that the movement-sensitive channels are responsible for signalling the occurrence of movement; the channels at higher spatial frequencies give no information about temporal changes. These two systems of channels are compared to the Y- and X-cells respectively of the cat.
A visual parallel-BCI speller based on the time-frequency coding strategy
NASA Astrophysics Data System (ADS)
Xu, Minpeng; Chen, Long; Zhang, Lixin; Qi, Hongzhi; Ma, Lan; Tang, Jiabei; Wan, Baikun; Ming, Dong
2014-04-01
Objective. Spelling is one of the most important issues in brain-computer interface (BCI) research. This paper is to develop a visual parallel-BCI speller system based on the time-frequency coding strategy in which the sub-speller switching among four simultaneously presented sub-spellers and the character selection are identified in a parallel mode. Approach. The parallel-BCI speller was constituted by four independent P300+SSVEP-B (P300 plus SSVEP blocking) spellers with different flicker frequencies, thereby all characters had a specific time-frequency code. To verify its effectiveness, 11 subjects were involved in the offline and online spellings. A classification strategy was designed to recognize the target character through jointly using the canonical correlation analysis and stepwise linear discriminant analysis. Main results. Online spellings showed that the proposed parallel-BCI speller had a high performance, reaching the highest information transfer rate of 67.4 bit min-1, with an average of 54.0 bit min-1 and 43.0 bit min-1 in the three rounds and five rounds, respectively. Significance. The results indicated that the proposed parallel-BCI could be effectively controlled by users with attention shifting fluently among the sub-spellers, and highly improved the BCI spelling performance.
Takagi, Atsuko; Harashima, Satoshi; Oshima, Yasuji
1985-01-01
Hybrid or polyploid clones of Saccharomyces cerevisiae produced by protoplast fusion were easily isolated by selecting transformants with the plasmid phenotype because the transformation was directly associated with cell fusion. When haploid cells were used as the original strain, the transformants were mostly diploids with a significant fraction of polyploids (triploids or tetraploids). Repeated transformation after curing the plasmid gave rise to clones with higher ploidy, but the frequency of cell fusion was severely reduced as ploidy increased. Images PMID:16346702
On estimating the effects of clock instability with flicker noise characteristics
NASA Technical Reports Server (NTRS)
Wu, S. C.
1981-01-01
A scheme for flicker noise generation is given. The second approach is that of successive segmentation: A clock fluctuation is represented by 2N piecewise linear segments and then converted into a summation of N+1 triangular pulse train functions. The statistics of the clock instability are then formulated in terms of two sample variances at N+1 specified averaging times. The summation converges very rapidly that a value of N 6 is seldom necessary. An application to radio interferometric geodesy shows excellent agreement between the two approaches. Limitations to and the relative merits of the two approaches are discussed.
Infrared and visible fusion face recognition based on NSCT domain
NASA Astrophysics Data System (ADS)
Xie, Zhihua; Zhang, Shuai; Liu, Guodong; Xiong, Jinquan
2018-01-01
Visible face recognition systems, being vulnerable to illumination, expression, and pose, can not achieve robust performance in unconstrained situations. Meanwhile, near infrared face images, being light- independent, can avoid or limit the drawbacks of face recognition in visible light, but its main challenges are low resolution and signal noise ratio (SNR). Therefore, near infrared and visible fusion face recognition has become an important direction in the field of unconstrained face recognition research. In this paper, a novel fusion algorithm in non-subsampled contourlet transform (NSCT) domain is proposed for Infrared and visible face fusion recognition. Firstly, NSCT is used respectively to process the infrared and visible face images, which exploits the image information at multiple scales, orientations, and frequency bands. Then, to exploit the effective discriminant feature and balance the power of high-low frequency band of NSCT coefficients, the local Gabor binary pattern (LGBP) and Local Binary Pattern (LBP) are applied respectively in different frequency parts to obtain the robust representation of infrared and visible face images. Finally, the score-level fusion is used to fuse the all the features for final classification. The visible and near infrared face recognition is tested on HITSZ Lab2 visible and near infrared face database. Experiments results show that the proposed method extracts the complementary features of near-infrared and visible-light images and improves the robustness of unconstrained face recognition.
A high-speed brain speller using steady-state visual evoked potentials.
Nakanishi, Masaki; Wang, Yijun; Wang, Yu-Te; Mitsukura, Yasue; Jung, Tzyy-Ping
2014-09-01
Implementing a complex spelling program using a steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) remains a challenge due to difficulties in stimulus presentation and target identification. This study aims to explore the feasibility of mixed frequency and phase coding in building a high-speed SSVEP speller with a computer monitor. A frequency and phase approximation approach was developed to eliminate the limitation of the number of targets caused by the monitor refresh rate, resulting in a speller comprising 32 flickers specified by eight frequencies (8-15 Hz with a 1 Hz interval) and four phases (0°, 90°, 180°, and 270°). A multi-channel approach incorporating Canonical Correlation Analysis (CCA) and SSVEP training data was proposed for target identification. In a simulated online experiment, at a spelling rate of 40 characters per minute, the system obtained an averaged information transfer rate (ITR) of 166.91 bits/min across 13 subjects with a maximum individual ITR of 192.26 bits/min, the highest ITR ever reported in electroencephalogram (EEG)-based BCIs. The results of this study demonstrate great potential of a high-speed SSVEP-based BCI in real-life applications.
A wavelet-based adaptive fusion algorithm of infrared polarization imaging
NASA Astrophysics Data System (ADS)
Yang, Wei; Gu, Guohua; Chen, Qian; Zeng, Haifang
2011-08-01
The purpose of infrared polarization image is to highlight man-made target from a complex natural background. For the infrared polarization images can significantly distinguish target from background with different features, this paper presents a wavelet-based infrared polarization image fusion algorithm. The method is mainly for image processing of high-frequency signal portion, as for the low frequency signal, the original weighted average method has been applied. High-frequency part is processed as follows: first, the source image of the high frequency information has been extracted by way of wavelet transform, then signal strength of 3*3 window area has been calculated, making the regional signal intensity ration of source image as a matching measurement. Extraction method and decision mode of the details are determined by the decision making module. Image fusion effect is closely related to the setting threshold of decision making module. Compared to the commonly used experiment way, quadratic interpolation optimization algorithm is proposed in this paper to obtain threshold. Set the endpoints and midpoint of the threshold searching interval as initial interpolation nodes, and compute the minimum quadratic interpolation function. The best threshold can be obtained by comparing the minimum quadratic interpolation function. A series of image quality evaluation results show this method has got improvement in fusion effect; moreover, it is not only effective for some individual image, but also for a large number of images.
Low Frequency of the ERG Oncogene Alterations in Prostate Cancer Patients from India.
Rawal, Sudhir; Young, Denise; Williams, Molly; Colombo, Monica; Krishnappa, Raghunath; Petrovics, Gyorgy; McLeod, David G; Srivastava, Shiv; Sesterhenn, Isabell A
2013-01-01
ERG oncogene fusions (predominantly TMPRSS2-ERG) represent the most common (50-70% frequency) and validated prostate cancer (CaP) genome alteration in the Western countries. A common TMPRSS2-ERG fusion type leads to the androgen dependent tumor cell specific expression of the TMPRSS2-ERG fusion transcript and amino terminally truncated ERG oncoprotein. CaP prevalence and aggressiveness, as well as genomic alterations vary in different geographic locations in the world. Recent studies from our group highlighted significantly lower frequency of ERG alterations in prostate index tumors of African American men (~30%) in comparison to Caucasian Americans (~60%). Further, much lower frequencies (10 -25%) of ERG alterations have been reported in studies from China and Japan. There is no study on ERG alterations in CaP patients from India, representing a significant portion of the world male population. This study focuses on the frequency of ERG oncoprotein expression in CaP patients from India. De-identified formalin-fixed paraffin-embedded (FFPE) specimens from radical prostatectomy (RP) specimens of 51 patients from the Rajiv Gandhi Cancer Institute and Research Centre (RGCI), New Delhi, India, were analyzed for ERG alterations. The ERG oncoprotein expression as a surrogate of ERG gene fusions was analyzed by using a highly specific ERG monoclonal antibody (9FY). TMPRSS2-ERG fusion was assessed by fluorescent in situ hybridization (FISH) assays using the break-apart ERG probes. Specimens reflecting prior hormonal treatment, or lacking any tumor content, were excluded from the analyses. Of the thirty evaluable specimens, ERG positive tumors were present in 8 cases (27%) and one tumor specimen exhibited rare ERG positive cells. None of the benign glands were positive for ERG supporting previous studies showing complete specificity of the ERG oncoprotein for detection of tumors cells in prostate. Frequency of ERG oncoprotein expression is much lower in CaP patients from India in comparison to higher frequency of ERG alterations noted in Western countries. ERG frequency in Indian CaP is similar to observations from Japan and China. Since ERG oncogenic activation is a promising biomarker and therapeutic target for CaP, careful evaluation of ERG is needed in CaP patients from different parts of the world.
NASA Astrophysics Data System (ADS)
Samnakay, Rameez; Balandin, Alexander A.; Srinivasan, Purushothaman
2017-09-01
Bias temperature instability (BTI) is one of the critical device degradation mechanisms in poly-Si/SiON and metal gate/high-k complementary metal-oxide-semiconductor (CMOS) technologies. Using the pre- and post-BTI flicker noise measurements, we investigated the bulk trap density, Nt, in both of these technologies. The low-frequency noise spectra were predominantly of 1/fγ type with γ < 1 for NMOS and ∼1 for PMOS. For SiON based technologies, the lower VTH degradation due to PBTI was noticed while considerable VTH degradation was observed for NBTI in both SiON and MGHK technologies. Both MGHK and SiON pFETs show a clear increase in the effective volume trap density, Nt, after NBTI. The increase in Nt in MGHK n-MOSFETs during PBTI is markedly higher than that in MGHK p-MOSFETs during NBTI. From 2012-2016 he was a Research Assistant with the Nano-Device Laboratory at the University of California - Riverside, as well as a member of the Quality and Reliability engineering team at Globalfoundries, Inc. during the summer of 2014. He has currently authored or co-authored 10 journal publications and numerous conference presentations. His current research interests include 1/f noise in high-k dielectrics and fabricated 2D van der Waal thin-film devices Mr. Samnakay's awards and honors include the Dean's Distinguished Fellowship Award (University of California-Riverside) and induction into the IEEE-HKN honors society. He also serves as a reviewer for 6 journals including Applied Physics Letters, Journal of Physics: Condensed Matter and Nanotechnology journals.
Feature-selective attention in healthy old age: a selective decline in selective attention?
Quigley, Cliodhna; Müller, Matthias M
2014-02-12
Deficient selection against irrelevant information has been proposed to underlie age-related cognitive decline. We recently reported evidence for maintained early sensory selection when older and younger adults used spatial selective attention to perform a challenging task. Here we explored age-related differences when spatial selection is not possible and feature-selective attention must be deployed. We additionally compared the integrity of feedforward processing by exploiting the well established phenomenon of suppression of visual cortical responses attributable to interstimulus competition. Electroencephalogram was measured while older and younger human adults responded to brief occurrences of coherent motion in an attended stimulus composed of randomly moving, orientation-defined, flickering bars. Attention was directed to horizontal or vertical bars by a pretrial cue, after which two orthogonally oriented, overlapping stimuli or a single stimulus were presented. Horizontal and vertical bars flickered at different frequencies and thereby elicited separable steady-state visual-evoked potentials, which were used to examine the effect of feature-based selection and the competitive influence of a second stimulus on ongoing visual processing. Age differences were found in feature-selective attentional modulation of visual responses: older adults did not show consistent modulation of magnitude or phase. In contrast, the suppressive effect of a second stimulus was robust and comparable in magnitude across age groups, suggesting that bottom-up processing of the current stimuli is essentially unchanged in healthy old age. Thus, it seems that visual processing per se is unchanged, but top-down attentional control is compromised in older adults when space cannot be used to guide selection.
Walter, Sabrina; Keitel, Christian; Müller, Matthias M
2016-01-01
Visual attention can be focused concurrently on two stimuli at noncontiguous locations while intermediate stimuli remain ignored. Nevertheless, behavioral performance in multifocal attention tasks falters when attended stimuli fall within one visual hemifield as opposed to when they are distributed across left and right hemifields. This "different-hemifield advantage" has been ascribed to largely independent processing capacities of each cerebral hemisphere in early visual cortices. Here, we investigated how this advantage influences the sustained division of spatial attention. We presented six isoeccentric light-emitting diodes (LEDs) in the lower visual field, each flickering at a different frequency. Participants attended to two LEDs that were spatially separated by an intermediate LED and responded to synchronous events at to-be-attended LEDs. Task-relevant pairs of LEDs were either located in the same hemifield ("within-hemifield" conditions) or separated by the vertical meridian ("across-hemifield" conditions). Flicker-driven brain oscillations, steady-state visual evoked potentials (SSVEPs), indexed the allocation of attention to individual LEDs. Both behavioral performance and SSVEPs indicated enhanced processing of attended LED pairs during "across-hemifield" relative to "within-hemifield" conditions. Moreover, SSVEPs demonstrated effective filtering of intermediate stimuli in "across-hemifield" condition only. Thus, despite identical physical distances between LEDs of attended pairs, the spatial profiles of gain effects differed profoundly between "across-hemifield" and "within-hemifield" conditions. These findings corroborate that early cortical visual processing stages rely on hemisphere-specific processing capacities and highlight their limiting role in the concurrent allocation of visual attention to multiple locations.
Using frequency tagging to quantify attentional deployment in a visual divided attention task.
Toffanin, Paolo; de Jong, Ritske; Johnson, Addie; Martens, Sander
2009-06-01
Frequency tagging is an EEG method based on the quantification of the steady state visual evoked potential (SSVEP) elicited from stimuli which flicker with a distinctive frequency. Because the amplitude of the SSVEP is modulated by attention such that attended stimuli elicit higher SSVEP amplitudes than do ignored stimuli, the method has been used to investigate the neural mechanisms of spatial attention. However, up to now it has not been shown whether the amplitude of the SSVEP is sensitive to gradations of attention and there has been debate about whether attention effects on the SSVEP are dependent on the tagging frequency used. We thus compared attention effects on SSVEP across three attention conditions-focused, divided, and ignored-with six different tagging frequencies. Participants performed a visual detection task (respond to the digit 5 embedded in a stream of characters). Two stimulus streams, one to the left and one to the right of fixation, were displayed simultaneously, each with a background grey square whose hue was sine-modulated with one of the six tagging frequencies. At the beginning of each trial a cue indicated whether targets on the left, right, or both sides should be responded to. Accuracy was higher in the focused- than in the divided-attention condition. SSVEP amplitudes were greatest in the focused-attention condition, intermediate in the divided-attention condition, and smallest in the ignored-attention condition. The effect of attention on SSVEP amplitude did not depend on the tagging frequency used. Frequency tagging appears to be a flexible technique for studying attention.
Investigation of Noises in GPS Time Series: Case Study on Epn Weekly Solutions
NASA Astrophysics Data System (ADS)
Klos, Anna; Bogusz, Janusz; Figurski, Mariusz; Kosek, Wieslaw; Gruszczynski, Maciej
2014-05-01
The noises in GPS time series are stated to be described the best by the combination of white (Gaussian) and power-law processes. They are mainly the effect of mismodelled satellite orbits, Earth orientation parameters, atmospheric effects, antennae phase centre effects, or of monument instability. Due to the fact, that velocities of permanent stations define the kinematic reference frame, they have to fulfil the requirement of being stable at 0.1 mm/yr. The previously performed researches showed, that the wrong assumption of noise model leads to the underestimation of velocities and their uncertainties from 2 up to even 11, especially in the Up direction. This presentation focuses on more than 200 EPN (EUREF Permanent Network) stations from the area of Europe with various monument types (concrete pillars, buildings, metal masts, with or without domes, placed on the ground or on the rock) and coordinates of weekly changes (GPS weeks 0834-1459). The topocentric components (North, East, Up) in ITRF2005 which come from the EPN Re-Processing made by the Military University of Technology Local Analysis Centre (MUT LAC) were processed with Maximum Likelihood Estimation (MLE) using CATS software. We have assumed the existence of few combinations of noise models (these are: white, flicker and random walk noise with integer spectral indices and power-law noise models with fractional spectral indices) and investigated which of them EPN weekly time series are likely to follow. The results show, that noises in GPS time series are described the best by the combination of white and flicker noise model. It is strictly related to the so-called common mode error (CME) that is spatially correlated error being one of the dominant error source in GPS solutions. We have assumed CME as spatially uniform, what was a good approximation for stations located hundreds of kilometres one to another. Its removal with spatial filtering reduces the amplitudes of white and flicker noise by a factor of 2 or 3. The assumption of white plus flicker plus random-walk noise (which is considered to be the effect of badly monumented stations) resulted in the random-walk amplitudes at the level of single millimetres for some of the stations, while for the majority of them no random-walk was detected, due to the fact that flicker noise prevails in GPS time series. The removal of CME caused the decrease in flicker noise amplitudes leading at the same time to greater random-walk amplitudes. The assumed combination of white plus power-law noise showed that the spectral indices for the best fitted noise model are unevenly distributed around -1 what also indicates the flicker noise existence in EPN weekly time series. The poster will present all of the assumed noise model combinations with the comparison of noise amplitudes before and after spatial filtering. Additionally, we will discuss over the latitude and longitude noise dependencies for the area of Europe to indicate any similarities between noise amplitudes and the location of stations. Finally, we will focus on the velocities with their uncertainties that were determined from EPN weekly solutions and show how the wrong assumption of noise model changes both of them.
Welcome Back: Responses of Female Bonobos (Pan paniscus) to Fusions.
Moscovice, Liza R; Deschner, Tobias; Hohmann, Gottfried
2015-01-01
In species with a high degree of fission-fusion social dynamics, fusions may trigger social conflict and thus provide an opportunity to identify sources of social tension and mechanisms related to its alleviation. We characterized behavioral and endocrine responses of captive female bonobos (Pan paniscus) to fusions within a zoo facility designed to simulate naturalistic fission-fusion social dynamics. We compared urinary cortisol levels and frequencies of aggression, grooming and socio-sexual interactions between female bonobos while in stable sub-groups and when one "joiner" was reunited with the "residents" of another sub-group. We hypothesized that fusions would trigger increases in aggression and cortisol levels among reunited joiners and resident females. We further predicted that females who face more uncertainty in their social interactions following fusions may use grooming and/or socio-sexual behavior to reduce social tension and aggression. The only aggression on reunion days occurred between reunited females, but frequencies of aggression remained low across non-reunion and reunion days, and there was no effect of fusions on cortisol levels. Fusions did not influence patterns of grooming, but there were increases in socio-sexual solicitations and socio-sexual interactions between joiners and resident females. Joiners who had been separated from residents for longer received the most solicitations, but were also more selective in their acceptance of solicitations and preferred to have socio-sexual interactions with higher-ranking residents. Our results suggest that socio-sexual interactions play a role in reintegrating female bonobos into social groups following fusions. In addition, females who receive a high number of solicitations are able to gain more control over their socio-sexual interactions and may use socio-sexual interactions for other purposes, such as to enhance their social standing.
Welcome Back: Responses of Female Bonobos (Pan paniscus) to Fusions
Moscovice, Liza R.; Deschner, Tobias; Hohmann, Gottfried
2015-01-01
In species with a high degree of fission-fusion social dynamics, fusions may trigger social conflict and thus provide an opportunity to identify sources of social tension and mechanisms related to its alleviation. We characterized behavioral and endocrine responses of captive female bonobos (Pan paniscus) to fusions within a zoo facility designed to simulate naturalistic fission-fusion social dynamics. We compared urinary cortisol levels and frequencies of aggression, grooming and socio-sexual interactions between female bonobos while in stable sub-groups and when one “joiner” was reunited with the “residents” of another sub-group. We hypothesized that fusions would trigger increases in aggression and cortisol levels among reunited joiners and resident females. We further predicted that females who face more uncertainty in their social interactions following fusions may use grooming and/or socio-sexual behavior to reduce social tension and aggression. The only aggression on reunion days occurred between reunited females, but frequencies of aggression remained low across non-reunion and reunion days, and there was no effect of fusions on cortisol levels. Fusions did not influence patterns of grooming, but there were increases in socio-sexual solicitations and socio-sexual interactions between joiners and resident females. Joiners who had been separated from residents for longer received the most solicitations, but were also more selective in their acceptance of solicitations and preferred to have socio-sexual interactions with higher-ranking residents. Our results suggest that socio-sexual interactions play a role in reintegrating female bonobos into social groups following fusions. In addition, females who receive a high number of solicitations are able to gain more control over their socio-sexual interactions and may use socio-sexual interactions for other purposes, such as to enhance their social standing. PMID:25996476
Simulation and analysis of atmospheric transmission performance in airborne Terahertz communication
NASA Astrophysics Data System (ADS)
Pan, Chengsheng; Shi, Xin; Liu, Chengyang; Wang, Xue; Ding, Yuanming
2018-02-01
For the special meteorological condition of high altitude transmission; first the influence of atmospheric turbulence on the Terahertz wireless communication is analyzed, and the atmospheric constants model with increase in height is given. On this basis, the relationship between the flicker index and the high altitude horizon transmission distance of the Terahertz wave is analyzed by simulation. Then, through the analysis of high altitude path loss and noise, the high altitude wireless link model is built. Finally, the link loss budget is given according to the current Terahertz device parameters, and bit error rate (BER) performance of on-off keyed modulation (OOK) and pulse position modulation (PPM) in four Terahertz frequency bands is compared and analyzed. All these above provided theoretical reference for high-altitude Terahertz wireless communication transmission.
Debelić, Vladimir; Drnovšek Olup, Brigita; Žižek, Bogomir; Skitek, Milan; Jerin, Aleš
2016-10-31
To determine whether higher glucose level and systemic oxidative stress decrease mean velocity (MV) index of the central retinal artery (CRA) during flickering light stimulation in type 1 diabetes (T1D). The study was performed in the period from 2008 to 2015 at the University Eye Clinic in Ljubljana. 41 patients with T1D and 37 participants without diabetes were included. MV in the CRA was measured using Doppler ultrasound diagnostics in basal conditions and during 8 Hz flickering light irritation. The plasma levels of glucose, fructosamine, 8-hydroxy-2'-deoxyguanosine (8-OHdG), triglycerides, cholesterol, and low-density lipoprotein (LDL) were measured. Patients with T1D had significantly higher levels of blood glucose (P<0.001), fructosamine (P<0.001), and 8-OHdG (P<0.001), but there were no significant differences in triglycerides (P=0.108), cholesterol (P=0.531), and LDL (P=0.645) between the groups. Patients with T1D also had a significantly lower MV index in the CRA (1.11±0.15 vs 1.24±0.23; P=0.010). In the T1D group, a significant negative correlation was found between the level of glucose (r=0.58; P<0.001), fructosamine (r=0.46; P=0.003), 8-OHdG (r=0.48; P=0.002) and the MV index in the CRA. At the same time, in this group fructosamine and 8-OHdG levels had a separate effect on the MV index (adjusted R2=0.38, P<0.001). Higher glucose levels, the medium-term glucose level, and systemic oxidative stress could importantly reduce retinal vasodilatation during flickering light irritation in patients with T1D.
Preface to Special Topic: Advances in Radio Frequency Physics in Fusion Plasmas
NASA Astrophysics Data System (ADS)
Tuccillo, Angelo A.; Phillips, Cynthia K.; Ceccuzzi, Silvio
2014-06-01
It has long been recognized that auxiliary plasma heating will be required to achieve the high temperature, high density conditions within a magnetically confined plasma in which a fusion "burn" may be sustained by copious fusion reactions. Consequently, the application of radio and microwave frequency electromagnetic waves to magnetically confined plasma, commonly referred to as RF, has been a major part of the program almost since its inception in the 1950s. These RF waves provide heating, current drive, plasma profile control, and Magnetohydrodynamics (MHD) stabilization. Fusion experiments employ electromagnetic radiation in a wide range of frequencies, from tens of MHz to hundreds of GHz. The fusion devices containing the plasma are typically tori, axisymmetric or non, in which the equilibrium magnetic fields are composed of a strong toroidal magnetic field generated by external coils, and a poloidal field created, at least in the symmetric configurations, by currents flowing in the plasma. The waves are excited in the peripheral regions of the plasma, by specially designed launching structures, and subsequently propagate into the core regions, where resonant wave-plasma interactions produce localized heating or other modification of the local equilibrium profiles. Experimental studies coupled with the development of theoretical models and advanced simulation codes over the past 40+ years have led to an unprecedented understanding of the physics of RF heating and current drive in the core of magnetic fusion devices. Nevertheless, there are serious gaps in our knowledge base that continue to have a negative impact on the success of ongoing experiments and that must be resolved as the program progresses to the next generation devices and ultimately to "demo" and "fusion power plant." A serious gap, at least in the ion cyclotron (IC) range of frequencies and partially in the lower hybrid frequency ranges, is the difficulty in coupling large amount of power to the plasma while minimizing the interaction between the plasma and launching structures. These potentially harmful interactions between the plasma and the vessel and launching structures are challenging: (i) significant and variable loss of power in the edge regions of confined plasmas and surrounding vessel structures adversely affect the core plasma performance and lifetime of a device; (ii) the launcher design is partly "trial and error," with the consequence that launchers may have to be reconfigured after initial tests in a given device, at an additional cost. Over the broader frequency range, another serious gap is a quantitative lack of understanding of the combined effects of nonlinear wave-plasma processes, energetic particle interactions and non-axisymmetric equilibrium effects on determining the overall efficiency of plasma equilibrium and stability profile control techniques using RF waves. This is complicated by a corresponding lack of predictive understanding of the time evolution of transport and stability processes in fusion plasmas.
Alternative Line Coding Scheme with Fixed Dimming for Visible Light Communication
NASA Astrophysics Data System (ADS)
Niaz, M. T.; Imdad, F.; Kim, H. S.
2017-01-01
An alternative line coding scheme called fixed-dimming on/off keying (FD-OOK) is proposed for visible-light communication (VLC). FD-OOK reduces the flickering caused by a VLC transmitter and can maintain a 50% dimming level. Simple encoder and decoder are proposed which generates codes where the number of bits representing one is same as the number of bits representing zero. By keeping the number of ones and zeros equal the change in the brightness of lighting may be minimized and kept constant at 50%, thereby reducing the flickering in VLC. The performance of FD-OOK is analysed with two parameters: the spectral efficiency and power requirement.
NASA Astrophysics Data System (ADS)
Lee, Minsuk; Won, Youngjae; Park, Byungjun; Lee, Seungrag
2017-02-01
Not only static characteristics but also dynamic characteristics of the red blood cell (RBC) contains useful information for the blood diagnosis. Quantitative phase imaging (QPI) can capture sample images with subnanometer scale depth resolution and millisecond scale temporal resolution. Various researches have been used QPI for the RBC diagnosis, and recently many researches has been developed to decrease the process time of RBC information extraction using QPI by the parallel computing algorithm, however previous studies are interested in the static parameters such as morphology of the cells or simple dynamic parameters such as root mean square (RMS) of the membrane fluctuations. Previously, we presented a practical blood test method using the time series correlation analysis of RBC membrane flickering with QPI. However, this method has shown that there is a limit to the clinical application because of the long computation time. In this study, we present an accelerated time series correlation analysis of RBC membrane flickering using the parallel computing algorithm. This method showed consistent fractal scaling exponent results of the surrounding medium and the normal RBC with our previous research.
NASA Astrophysics Data System (ADS)
van der Veen, Rob L. P.; Berendschot, Tos T. J. M.; Makridaki, Maria; Hendrikse, Fred; Carden, David; Murray, Ian J.
2009-11-01
A comparison of macular pigment optical density (MPOD) spatial profiles determined by an optical and a psychophysical technique is presented. We measured the right eyes of 19 healthy individuals, using fundus reflectometry at 0, 1, 2, 4, 6, and 8 deg eccentricity; and heterochromatic flicker photometry (HFP) at 0, 0.5, 1, 2, 3, 4, 5, 6, and 7 deg, and a reference point at 8 deg eccentricity. We found a strong correlation between the two techniques. However, the absolute estimates obtained by fundus reflectometry data were higher than by HFP. These differences could partly be explained by the fact that at 8 deg eccentricity the MPOD is not zero, as assumed in HFP. Furthermore, when performing HFP for eccentricities of <1 deg, we had to assume that subjects set flicker thresholds at 0.4 deg horizontal translation when using a 1-deg stimulus. MPOD profiles are very similar for both techniques if, on average, 0.05 DU is added to the HFP data at all eccentricities. An additional correction factor, dependent on the steepness of the MPOD spatial distribution, is required for 0 deg.
CALiPER Report 20.2: Dimming, Flicker, and Power Quality Characteristics of LED PAR38 Lamps
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
2014-03-31
This report focuses on the flicker and power quality performance of the Series 20 lamps at full output and various dimmed levels. All of the Series 20 PAR38 lamps that manufacturers claimed to be dimmable (including all halogen lamps) were evaluated individually (one lamp at a time) both on a switch and under the control of a phase-cut dimmer designed for use with "all classes of bulbs." Measurements of luminous flux, flicker, and power quality were taken at 10 target dimmed settings and compared with operation on a switch. Because only a single unit of each product was evaluated onmore » a single dimmer that may or may not have been recommended by its manufacturer, this report focuses on the performance of the products relative to each other, rather than the best-case performance of each lamp or variation in performance delivered from each lamp. Despite these limitations, the results suggest that LED performance is improving, and performance trends are beginning to emerge, perhaps due in part to the identification of preferred LED driver strategies for lamp products.« less
Application of tooth brushing behavior to active rest.
Sadachi, Hidetoshi; Murakami, Yoshinori; Tonomura, Manabu; Yada, Yukihiro; Simoyama, Ichiro
2010-01-01
We evaluated the usefulness of tooth brushing with toothpaste as active rest using the flicker value as a physiological parameter and a subjective questionnaire as a psychological parameter. Seventeen healthy, right-handed subjects (12 males and 5 females) aged 22.5 +/- 1.5 yr (mean +/- standard deviation) were randomly divided into tooth brushing with toothpaste (N=9) and non-tooth brushing groups (N=8). The subjects performed a serial calculation task for 20 min using personal computers. Subsequently, the tooth brushing group brushed their teeth, and the flicker value and mood were compared before and after the tooth brushing. The flicker value significantly increased in the tooth brushing group compared with the non-tooth brushing group (p<0.05). Concerning the mood, in the tooth brushing group, the incidence of a "feeling of being refreshed" significantly increased (p<0.05), that of "concentration power" or a "feeling of clear-headedness" tended to increase (p<0.1), and that of "lassitude" or "sleepiness" significantly decreased (p<0.01). Somatosensory stimulation and intraoral tactile stimulation during tooth brushing activated cerebral activity, producing refreshing effects. These results suggest the applicability of tooth brushing to active rest.
Multimodal Medical Image Fusion by Adaptive Manifold Filter.
Geng, Peng; Liu, Shuaiqi; Zhuang, Shanna
2015-01-01
Medical image fusion plays an important role in diagnosis and treatment of diseases such as image-guided radiotherapy and surgery. The modified local contrast information is proposed to fuse multimodal medical images. Firstly, the adaptive manifold filter is introduced into filtering source images as the low-frequency part in the modified local contrast. Secondly, the modified spatial frequency of the source images is adopted as the high-frequency part in the modified local contrast. Finally, the pixel with larger modified local contrast is selected into the fused image. The presented scheme outperforms the guided filter method in spatial domain, the dual-tree complex wavelet transform-based method, nonsubsampled contourlet transform-based method, and four classic fusion methods in terms of visual quality. Furthermore, the mutual information values by the presented method are averagely 55%, 41%, and 62% higher than the three methods and those values of edge based similarity measure by the presented method are averagely 13%, 33%, and 14% higher than the three methods for the six pairs of source images.
Caffeine antagonism of alcohol-induced driving impairment.
Liguori, A; Robinson, J H
2001-07-01
The extent to which caffeine antagonizes alcohol-induced impairment of simulated automobile driving at the current lowest legal American limit (0.08% BrAC) was the focus of this study. Fifteen adults swallowed a capsule (0, 200, or 400 mg caffeine) then drank a beverage (0.0 or 0.6 g/kg ethanol) in a within-subject, double-blind, randomized procedure. Forty-five minutes later, participants completed a test battery of subjective effects scales, dynamic posturography, critical flicker fusion (CFF), choice reaction time (CRT), divided attention (Stroop test), and simulated driving. Alcohol alone increased ratings of 'dizzy', 'drug effect', and 'high', slowed CRT and brake latency, and increased body sway. Caffeine alone increased ratings of 'alert' and 'jittery', but did not significantly affect body sway or psychomotor performance. Both caffeine doses comparably counteracted alcohol impairment of brake latency but not CRT or body sway. Brake latency with either alcohol-caffeine combination remained significantly longer than that with placebo. Stroop and CFF performance were unaffected by any drug condition. The results suggest that caffeine may increase alertness and improve reaction time after alcohol use but will not completely counteract alcohol impairment in a driver.
[Randomized double-blind comparative study of minaprine (200mg/j) and of placebo on memory loss].
Allain, H; Belliard, S; Lieury, A; Menard, G; Patat, A; Le Coz, F; Gandon, J M
1996-01-01
Thirty five subjects (age: 45-69 years) with subjective memory loss, without any other neuropsychiatric or somatic disease, were recruited in a phase II study. This double blind randomized versus placebo controlled study compared the effects of minaprine (200 mg/d) with placebo, in two parallel groups, during 2 months, on memory, attention and vigilance. Three psychometric tests were the main criteria of assessment: a standardized battery of memory tests (SM 5), the dual-coding test, the analysis of choice reaction times (CRT) and the critical flicker fusion point (CFF). A positive effect of minaprine was detected on words delayed recall (p = 0.028) and immediate recognition of words (p = 0.049). The global clinical tests (CGI, MacNair scale) were not statistically modified. Tolerability of minaprine and placebo were comparable. A positive pharmacodynamic activity on mnemonic performance is thus demonstrated in favour of minaprine (200 mg/d) in this specific population characterized by a memory complaint. These results would lead to a phase III study in which the main criteria would be global scales in order to confirm the clinical reliability of the present results.
Wang, Shau-Chun; Huang, Chih-Min; Chiang, Shu-Min
2007-08-17
This paper reports a simple chemometric technique to alter the noise spectrum of liquid chromatography-tandem mass spectrometry (LC-MS-MS) chromatogram between two consecutive matched filter procedures to improve the peak signal-to-noise (S/N) ratio enhancement. This technique is to multiply one match-filtered LC-MS-MS chromatogram with another artificial chromatogram added with thermal noises prior to the second matched filter. Because matched filter cannot eliminate low-frequency components inherent in the flicker noises of spike-like sharp peaks randomly riding on LC-MS-MS chromatograms, efficient peak S/N ratio improvement cannot be accomplished using one-step or consecutive matched filter procedures to process LC-MS-MS chromatograms. In contrast, when the match-filtered LC-MS-MS chromatogram is conditioned with the multiplication alteration prior to the second matched filter, much better efficient ratio improvement is achieved. The noise frequency spectrum of match-filtered chromatogram, which originally contains only low-frequency components, is altered to span a boarder range with multiplication operation. When the frequency range of this modified noise spectrum shifts toward higher frequency regime, the second matched filter, working as a low-pass filter, is able to provide better filtering efficiency to obtain higher peak S/N ratios. Real LC-MS-MS chromatograms containing random spike-like peaks, of which peak S/N ratio improvement is less than four times with two consecutive matched filters typically, are remedied to accomplish much better ratio enhancement approximately 16-folds when the noise frequency spectrum is modified between two matched filters.
NASA Astrophysics Data System (ADS)
Tang, Jian; Qiao, Junfei; Wu, ZhiWei; Chai, Tianyou; Zhang, Jian; Yu, Wen
2018-01-01
Frequency spectral data of mechanical vibration and acoustic signals relate to difficult-to-measure production quality and quantity parameters of complex industrial processes. A selective ensemble (SEN) algorithm can be used to build a soft sensor model of these process parameters by fusing valued information selectively from different perspectives. However, a combination of several optimized ensemble sub-models with SEN cannot guarantee the best prediction model. In this study, we use several techniques to construct mechanical vibration and acoustic frequency spectra of a data-driven industrial process parameter model based on selective fusion multi-condition samples and multi-source features. Multi-layer SEN (MLSEN) strategy is used to simulate the domain expert cognitive process. Genetic algorithm and kernel partial least squares are used to construct the inside-layer SEN sub-model based on each mechanical vibration and acoustic frequency spectral feature subset. Branch-and-bound and adaptive weighted fusion algorithms are integrated to select and combine outputs of the inside-layer SEN sub-models. Then, the outside-layer SEN is constructed. Thus, "sub-sampling training examples"-based and "manipulating input features"-based ensemble construction methods are integrated, thereby realizing the selective information fusion process based on multi-condition history samples and multi-source input features. This novel approach is applied to a laboratory-scale ball mill grinding process. A comparison with other methods indicates that the proposed MLSEN approach effectively models mechanical vibration and acoustic signals.
NASA Astrophysics Data System (ADS)
Li, Xiaosong; Li, Huafeng; Yu, Zhengtao; Kong, Yingchun
2015-07-01
An efficient multifocus image fusion scheme in nonsubsampled contourlet transform (NSCT) domain is proposed. Based on the property of optical imaging and the theory of defocused image, we present a selection principle for lowpass frequency coefficients and also investigate the connection between a low-frequency image and the defocused image. Generally, the NSCT algorithm decomposes detail image information indwells in different scales and different directions in the bandpass subband coefficient. In order to correctly pick out the prefused bandpass directional coefficients, we introduce multiscale curvature, which not only inherits the advantages of windows with different sizes, but also correctly recognizes the focused pixels from source images, and then develop a new fusion scheme of the bandpass subband coefficients. The fused image can be obtained by inverse NSCT with the different fused coefficients. Several multifocus image fusion methods are compared with the proposed scheme. The experimental results clearly indicate the validity and superiority of the proposed scheme in terms of both the visual qualities and the quantitative evaluation.
Tsukasaki, Wakako; Maruyama, Jun-Ichi; Kitamoto, Katsuhiko
2014-01-01
Hyphal fusion is involved in the formation of an interconnected colony in filamentous fungi, and it is the first process in sexual/parasexual reproduction. However, it was difficult to evaluate hyphal fusion efficiency due to the low frequency in Aspergillus oryzae in spite of its industrial significance. Here, we established a method to quantitatively evaluate the hyphal fusion ability of A. oryzae with mixed culture of two different auxotrophic strains, where the ratio of heterokaryotic conidia growing without the auxotrophic requirements reflects the hyphal fusion efficiency. By employing this method, it was demonstrated that AoSO and AoFus3 are required for hyphal fusion, and that hyphal fusion efficiency of A. oryzae was increased by depleting nitrogen source, including large amounts of carbon source, and adjusting pH to 7.0.
Multiscale Medical Image Fusion in Wavelet Domain
Khare, Ashish
2013-01-01
Wavelet transforms have emerged as a powerful tool in image fusion. However, the study and analysis of medical image fusion is still a challenging area of research. Therefore, in this paper, we propose a multiscale fusion of multimodal medical images in wavelet domain. Fusion of medical images has been performed at multiple scales varying from minimum to maximum level using maximum selection rule which provides more flexibility and choice to select the relevant fused images. The experimental analysis of the proposed method has been performed with several sets of medical images. Fusion results have been evaluated subjectively and objectively with existing state-of-the-art fusion methods which include several pyramid- and wavelet-transform-based fusion methods and principal component analysis (PCA) fusion method. The comparative analysis of the fusion results has been performed with edge strength (Q), mutual information (MI), entropy (E), standard deviation (SD), blind structural similarity index metric (BSSIM), spatial frequency (SF), and average gradient (AG) metrics. The combined subjective and objective evaluations of the proposed fusion method at multiple scales showed the effectiveness and goodness of the proposed approach. PMID:24453868
Improved Frequency Fluctuation Model for Spectral Line Shape Calculations in Fusion Plasmas
NASA Astrophysics Data System (ADS)
Ferri, S.; Calisti, A.; Mossé, C.; Talin, B.; Lisitsa, V.
2010-10-01
A very fast method to calculate spectral line shapes emitted by plasmas accounting for charge particle dynamics and effects of an external magnetic field is proposed. This method relies on a new formulation of the Frequency Fluctuation Model (FFM), which yields to an expression of the dynamic line profile as a functional of the static distribution function of frequencies. This highly efficient formalism, not limited to hydrogen-like systems, allows to calculate pure Stark and Stark-Zeeman line shapes for a wide range of density, temperature and magnetic field values, which is of importance in plasma physics and astrophysics. Various applications of this method are presented for conditions related to fusion plasmas.
Russian national time scale long-term stability
NASA Astrophysics Data System (ADS)
Alshina, A. P.; Gaigerov, B. A.; Koshelyaevsky, N. B.; Pushkin, S. B.
1994-05-01
The Institute of Metrology for Time and Space NPO 'VNIIFTRI' generates the National Time Scale (NTS) of Russia -- one of the most stable time scales in the world. Its striking feature is that it is based on a free ensemble of H-masers only. During last two years the estimations of NTS longterm stability based only on H-maser intercomparison data gives a flicker floor of about (2 to 3) x 10(exp -15) for averaging times from 1 day to 1 month. Perhaps the most significant feature for a time laboratory is an extremely low possible frequency drift -- it is too difficult to estimate it reliably. The other estimations, free from possible inside the ensemble correlation phenomena, are available based on the time comparison of NTS relative to the stable enough time scale of outer laboratories. The data on NTS comparison relative to the time scale of secondary time and frequency standards at Golitzino and Irkutsk in Russia and relative to NIST, PTB and USNO using GLONASS and GPS time transfer links gives stability estimations which are close to that based on H-maser intercomparisons.
Subtle flickering in Cepheids: Kepler and MOST
NASA Astrophysics Data System (ADS)
Evans, Nancy Remage; Szabó, Robert; Szabados, Laszlo; Derekas, Aliz; Matthews, Jaymie M.; Cameron, Chris; the MOST Team
2014-02-01
Fundamental mode classical Cepheids have light curves which repeat accurately enough that we can watch them evolve (change period). The new level of accuracy and quantity of data with the Kepler and MOST satellites probes this further. An intriguing result was found in the long time-series of Kepler data for V1154 Cyg the one classical Cepheid (fundamental mode, P = 4.9 d) in the field, which has short term changes in period (~=20 minutes), correlated for ~=10 cycles (period jitter). To follow this up, we obtained a month long series of observations of the fundamental mode Cepheid RT Aur and the first overtone pulsator SZ Tau. RT Aur shows the traditional strict repetition of the light curve, with the Fourier amplitude ratio R 1/R 2 remaining nearly constant. The light curve of SZ Tau, on the other hand, fluctuates in amplitude ratio at the level of approximately 50%. Furthermore prewhitening the RT Aur data with 10 frequencies reduces the Fourier spectrum to noise. For SZ Tau, considerable power is left after this prewhitening in a complicated variety of frequencies.
Russian national time scale long-term stability
NASA Technical Reports Server (NTRS)
Alshina, A. P.; Gaigerov, B. A.; Koshelyaevsky, N. B.; Pushkin, S. B.
1994-01-01
The Institute of Metrology for Time and Space NPO 'VNIIFTRI' generates the National Time Scale (NTS) of Russia -- one of the most stable time scales in the world. Its striking feature is that it is based on a free ensemble of H-masers only. During last two years the estimations of NTS longterm stability based only on H-maser intercomparison data gives a flicker floor of about (2 to 3) x 10(exp -15) for averaging times from 1 day to 1 month. Perhaps the most significant feature for a time laboratory is an extremely low possible frequency drift -- it is too difficult to estimate it reliably. The other estimations, free from possible inside the ensemble correlation phenomena, are available based on the time comparison of NTS relative to the stable enough time scale of outer laboratories. The data on NTS comparison relative to the time scale of secondary time and frequency standards at Golitzino and Irkutsk in Russia and relative to NIST, PTB and USNO using GLONASS and GPS time transfer links gives stability estimations which are close to that based on H-maser intercomparisons.
Change detection in synthetic aperture radar images based on image fusion and fuzzy clustering.
Gong, Maoguo; Zhou, Zhiqiang; Ma, Jingjing
2012-04-01
This paper presents an unsupervised distribution-free change detection approach for synthetic aperture radar (SAR) images based on an image fusion strategy and a novel fuzzy clustering algorithm. The image fusion technique is introduced to generate a difference image by using complementary information from a mean-ratio image and a log-ratio image. In order to restrain the background information and enhance the information of changed regions in the fused difference image, wavelet fusion rules based on an average operator and minimum local area energy are chosen to fuse the wavelet coefficients for a low-frequency band and a high-frequency band, respectively. A reformulated fuzzy local-information C-means clustering algorithm is proposed for classifying changed and unchanged regions in the fused difference image. It incorporates the information about spatial context in a novel fuzzy way for the purpose of enhancing the changed information and of reducing the effect of speckle noise. Experiments on real SAR images show that the image fusion strategy integrates the advantages of the log-ratio operator and the mean-ratio operator and gains a better performance. The change detection results obtained by the improved fuzzy clustering algorithm exhibited lower error than its preexistences.
Spine surgery in geriatric patients: Sometimes unnecessary, too much, or too little
Epstein, Nancy E.
2011-01-01
Background: Although the frequency of spinal surgical procedures has been increasing, particularly in patients of age 65 and over (geriatric), multiple overlapping comorbidities increase their risk/complication rates. Nevertheless, sometimes these high-risk geriatric patients are considered for “unnecessary”, too much (instrumented fusions), or too little [minimally invasive surgery (MIS)] spine surgery. Methods: In a review of the literature and reanalysis of data from prior studies, attention was focused on the increasing number of operations offered to geriatric patients, their increased comorbidities, and the offers for “unnecessary” spine fusions, including both major open and MIS procedures. Results: In the literature, the frequency of spine operations, particularly instrumented fusions, has markedly increased in patients of age 65 and older. Specifically, in a 2010 report, a 28-fold increase in anterior discectomy and fusion was observed for geriatric patients. Geriatric patients with more comorbid factors, including diabetes, hypertension, coronary artery disease (prior procedures), depression, and obesity, experience higher postoperative complication rates and costs. Sometimes “unnecessary”, too much (instrumented fusions), and too little (MIS spine) surgeries were offered to geriatric patients, which increased the morbidity. One study observed a 10% complication rate for decompression alone (average age 76.4), a 40% complication rate for decompression/limited fusion (average age 70.4), and a 56% complication rate for full curve fusions (average age 62.5). Conclusions: Increasingly, spine operations in geriatric patients with multiple comorbidities are sometimes “unnecessary”, offer too much surgery (instrumentation), or too little surgery (MIS). PMID:22276241
Raman spectroscopic evidence of tissue restructuring in heat-induced tissue fusion.
Su, Lei; Cloyd, Kristy L; Arya, Shobhit; Hedegaard, Martin A B; Steele, Joseph A M; Elson, Daniel S; Stevens, Molly M; Hanna, George B
2014-09-01
Heat-induced tissue fusion via radio-frequency (RF) energy has gained wide acceptance clinically and here we present the first optical-Raman-spectroscopy study on tissue fusion samples in vitro. This study provides direct insights into tissue constituent and structural changes on the molecular level, exposing spectroscopic evidence for the loss of distinct collagen fibre rich tissue layers as well as the denaturing and restructuring of collagen crosslinks post RF fusion. These findings open the door for more advanced optical feedback-control methods and characterization during heat-induced tissue fusion, which will lead to new clinical applications of this promising technology. Copyright © 2014 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim.
Signal and Noise in FET-Nanopore Devices.
Parkin, William M; Drndić, Marija
2018-02-23
The combination of a nanopore with a local field-effect transistor (FET-nanopore), like a nanoribbon, nanotube, or nanowire, in order to sense single molecules translocating through the pore is promising for DNA sequencing at megahertz bandwidths. Previously, it was experimentally determined that the detection mechanism was due to local potential fluctuations that arise when an analyte enters a nanopore and constricts ion flow through it, rather than the theoretically proposed mechanism of direct charge coupling between the DNA and nanowire. However, there has been little discussion on the experimentally observed detection mechanism and its relation to the operation of real devices. We model the intrinsic signal and noise in such an FET-nanopore device and compare the results to the ionic current signal. The physical dimensions of DNA molecules limit the change in gate voltage on the FET to below 40 mV. We discuss the low-frequency flicker noise (<10 kHz), medium-frequency thermal noise (<100 kHz), and high-frequency capacitive noise (>100 kHz) in FET-nanopore devices. At bandwidths dominated by thermal noise, the signal-to-noise ratio in FET-nanopore devices is lower than in the ionic current signal. At high frequencies, where noise due to parasitic capacitances in the amplifier and chip is the dominant source of noise in ionic current measurements, high-transconductance FET-nanopore devices can outperform ionic current measurements.
Koban, Leonie; Ninck, Markus; Li, Jun; Gisler, Thomas; Kissler, Johanna
2010-07-27
Emotional stimuli are preferentially processed compared to neutral ones. Measuring the magnetic resonance blood-oxygen level dependent (BOLD) response or EEG event-related potentials, this has also been demonstrated for emotional versus neutral words. However, it is currently unclear whether emotion effects in word processing can also be detected with other measures such as EEG steady-state visual evoked potentials (SSVEPs) or optical brain imaging techniques. In the present study, we simultaneously performed SSVEP measurements and near-infrared diffusing-wave spectroscopy (DWS), a new optical technique for the non-invasive measurement of brain function, to measure brain responses to neutral, pleasant, and unpleasant nouns flickering at a frequency of 7.5 Hz. The power of the SSVEP signal was significantly modulated by the words' emotional content at occipital electrodes, showing reduced SSVEP power during stimulation with pleasant compared to neutral nouns. By contrast, the DWS signal measured over the visual cortex showed significant differences between stimulation with flickering words and baseline periods, but no modulation in response to the words' emotional significance. This study is the first investigation of brain responses to emotional words using simultaneous measurements of SSVEPs and DWS. Emotional modulation of word processing was detected with EEG SSVEPs, but not by DWS. SSVEP power for emotional, specifically pleasant, compared to neutral words was reduced, which contrasts with previous results obtained when presenting emotional pictures. This appears to reflect processing differences between symbolic and pictorial emotional stimuli. While pictures prompt sustained perceptual processing, decoding the significance of emotional words requires more internal associative processing. Reasons for an absence of emotion effects in the DWS signal are discussed.
Lateralized electrical brain activity reveals covert attention allocation during speaking.
Rommers, Joost; Meyer, Antje S; Praamstra, Peter
2017-01-27
Speakers usually begin to speak while only part of the utterance has been planned. Earlier work has shown that speech planning processes are reflected in speakers' eye movements as they describe visually presented objects. However, to-be-named objects can be processed to some extent before they have been fixated upon, presumably because attention can be allocated to objects covertly, without moving the eyes. The present study investigated whether EEG could track speakers' covert attention allocation as they produced short utterances to describe pairs of objects (e.g., "dog and chair"). The processing difficulty of each object was varied by presenting it in upright orientation (easy) or in upside down orientation (difficult). Background squares flickered at different frequencies in order to elicit steady-state visual evoked potentials (SSVEPs). The N2pc component, associated with the focusing of attention on an item, was detectable not only prior to speech onset, but also during speaking. The time course of the N2pc showed that attention shifted to each object in the order of mention prior to speech onset. Furthermore, greater processing difficulty increased the time speakers spent attending to each object. This demonstrates that the N2pc can track covert attention allocation in a naming task. In addition, an effect of processing difficulty at around 200-350ms after stimulus onset revealed early attention allocation to the second to-be-named object. The flickering backgrounds elicited SSVEPs, but SSVEP amplitude was not influenced by processing difficulty. These results help complete the picture of the coordination of visual information uptake and motor output during speaking. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Koniczek, Martin; El-Mohri, Youcef; Antonuk, Larry E.; Liang, Albert; Zhao, Qihua; Jiang, Hao
2011-03-01
A decade after the clinical introduction of active matrix, flat-panel imagers (AMFPIs), the performance of this technology continues to be limited by the relatively large additive electronic noise of these systems - resulting in significant loss of detective quantum efficiency (DQE) under conditions of low exposure or high spatial frequencies. An increasingly promising approach for overcoming such limitations involves the incorporation of in-pixel amplification circuits, referred to as active pixel architectures (AP) - based on low-temperature polycrystalline silicon (poly-Si) thin-film transistors (TFTs). In this study, a methodology for theoretically examining the limiting noise and DQE performance of circuits employing 1-stage in-pixel amplification is presented. This methodology involves sophisticated SPICE circuit simulations along with cascaded systems modeling. In these simulations, a device model based on the RPI poly-Si TFT model is used with additional controlled current sources corresponding to thermal and flicker (1/f) noise. From measurements of transfer and output characteristics (as well as current noise densities) performed upon individual, representative, poly-Si TFTs test devices, model parameters suitable for these simulations are extracted. The input stimuli and operating-point-dependent scaling of the current sources are derived from the measured current noise densities (for flicker noise), or from fundamental equations (for thermal noise). Noise parameters obtained from the simulations, along with other parametric information, is input to a cascaded systems model of an AP imager design to provide estimates of DQE performance. In this paper, this method of combining circuit simulations and cascaded systems analysis to predict the lower limits on additive noise (and upper limits on DQE) for large area AP imagers with signal levels representative of those generated at fluoroscopic exposures is described, and initial results are reported.
Particle and Photon Detection: Counting and Energy Measurement
Janesick, James; Tower, John
2016-01-01
Fundamental limits for photon counting and photon energy measurement are reviewed for CCD and CMOS imagers. The challenges to extend photon counting into the visible/nIR wavelengths and achieve energy measurement in the UV with specific read noise requirements are discussed. Pixel flicker and random telegraph noise sources are highlighted along with various methods used in reducing their contribution on the sensor’s read noise floor. Practical requirements for quantum efficiency, charge collection efficiency, and charge transfer efficiency that interfere with photon counting performance are discussed. Lastly we will review current efforts in reducing flicker noise head-on, in hopes to drive read noise substantially below 1 carrier rms. PMID:27187398
Li, Cuiling; Xia, Guangmin; Xiang, Fengning; Zhou, Chuanen; Cheng, Aixia
2004-12-01
Two types of protoplasts of wheat (Triticum aestivum L. cv. Jinan 177) were used in fusion experiments--cha9, with a high division frequency, and 176, with a high regeneration frequency. The fusion combination of either cha9 or 176 protoplasts with Russian wildrye protoplasts failed to produce regenerated calli. When a mixture of cha9 and 176 protoplasts were fused with those of Russian wildrye, 14 fusion-derived calli were produced, of which seven differentiated into green plants and two differentiated into albinos. The morphology of all hybrid plants strongly resembled that of the parental wheat type. The hybrid nature of the cell lines was confirmed by cytological, isozyme, random amplified polymorphic DNA (RAPD) and genomic in situ hybridization (GISH) analyses. GISH analysis revealed that only chromosome fragments of Russian wildrye were transferred to the wheat chromosomes of hybrid calli and plants. Simple sequence repeat (SSR) analysis of the chloroplast genome of the hybrids with seven pairs of wheat-specific chloroplast microsatellite primers indicated that all of the cell lines had band patterns identical to wheat. Our results show that highly asymmetric somatic hybrid calli and plants can be produced via symmetric fusion in a triparental fusion system. The dominant effect of two wheat cell lines on the exclusion of Russian wildrye chromosomes is discussed.
BCI demographics II: how many (and what kinds of) people can use a high-frequency SSVEP BCI?
Volosyak, Ivan; Valbuena, Diana; Lüth, Thorsten; Malechka, Tatsiana; Gräser, Axel
2011-06-01
Brain-computer interface (BCI) systems use brain activity as an input signal and enable communication without movement. This study is a successor of our previous study (BCI demographics I) and examines correlations among BCI performance, personal preferences, and different subject factors such as age or gender for two sets of steady-state visual evoked potential (SSVEP) stimuli: one in the medium frequency range (13, 14, 15 and 16 Hz) and another in the high-frequency range (34, 36, 38, 40 Hz). High-frequency SSVEPs (above 30 Hz) diminish user fatigue and risk of photosensitive epileptic seizures. Results showed that most people, despite having no prior BCI experience, could use the SSVEP-based Bremen-BCI system in a very noisy field setting at a fair. Results showed that demographic parameters as well as handedness, tiredness, alcohol and caffeine consumption, etc., have no significant effect on the performance of SSVEP-based BCI. Most subjects did not consider the flickering stimuli annoying, only five out of total 86 participants indicated change in fatigue during the experiment. 84 subjects performed with a mean information transfer rate of 17.24 ±6.99 bit/min and an accuracy of 92.26 ±7.82% with the medium frequency set, whereas only 56 subjects performed with a mean information transfer rate of 12.10 ±7.31 bit/min and accuracy of 89.16 ±9.29% with the high-frequency set. These and other demographic analyses may help identify the best BCI for each user.
DISCOVERY OF FAST, LARGE-AMPLITUDE OPTICAL VARIABILITY OF V648 Car (=SS73-17)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Angeloni, R.; Di Mille, F.; Ferreira Lopes, C. E.
We report on the discovery of large-amplitude flickering from V648 Car (= SS73-17), a poorly studied object listed among the very few hard X-ray-emitting symbiotic stars. We performed millimagnitude precision optical photometry with the Swope Telescope at the Las Campanas Observatory, Chile, and found that V648 Car shows large U-band variability over timescales of minutes. To our knowledge, it exhibits some of the largest flickering of a symbiotic star ever reported. Our finding supports the hypothesis that symbiotic white dwarfs producing hard X-rays are predominantly powered by accretion, rather than quasi-steady nuclear burning, and have masses close to the Chandrasekharmore » limit. No significant periodicity is evident from the flickering light curve. The All Sky Automated Survey long-term V light curve suggests the presence of a tidally distorted giant accreting via Roche lobe overflow, and a binary period of {approx}520 days. On the basis of the outstanding physical properties of V648 Car as hinted at by its fast and long-term optical variability, as well as by its nature as a hard X-ray emitter, we therefore call for simultaneous follow-up observations in different bands, ideally combined with time-resolved optical spectroscopy.« less
Decoding of top-down cognitive processing for SSVEP-controlled BMI
Min, Byoung-Kyong; Dähne, Sven; Ahn, Min-Hee; Noh, Yung-Kyun; Müller, Klaus-Robert
2016-01-01
We present a fast and accurate non-invasive brain-machine interface (BMI) based on demodulating steady-state visual evoked potentials (SSVEPs) in electroencephalography (EEG). Our study reports an SSVEP-BMI that, for the first time, decodes primarily based on top-down and not bottom-up visual information processing. The experimental setup presents a grid-shaped flickering line array that the participants observe while intentionally attending to a subset of flickering lines representing the shape of a letter. While the flickering pixels stimulate the participant’s visual cortex uniformly with equal probability, the participant’s intention groups the strokes and thus perceives a ‘letter Gestalt’. We observed decoding accuracy of 35.81% (up to 65.83%) with a regularized linear discriminant analysis; on average 2.05-fold, and up to 3.77-fold greater than chance levels in multi-class classification. Compared to the EEG signals, an electrooculogram (EOG) did not significantly contribute to decoding accuracies. Further analysis reveals that the top-down SSVEP paradigm shows the most focalised activation pattern around occipital visual areas; Granger causality analysis consistently revealed prefrontal top-down control over early visual processing. Taken together, the present paradigm provides the first neurophysiological evidence for the top-down SSVEP BMI paradigm, which potentially enables multi-class intentional control of EEG-BMIs without using gaze-shifting. PMID:27808125
Ng, Leo; Rosalie, Simon M; Sherry, Dorianne; Loh, Wei Bing; Sjurseth, Andreas M; Iyengar, Shrikant; Wild, Catherine Y
2018-03-01
Research has revealed that field hockey drag flickers have greater odds of hip and lumbar injuries compared to non-drag flickers (DF). This study aimed to compare the biomechanics of a field hockey hit and a specialised field hockey drag flick. Eighteen male and seven female specialised hockey DF performed a hit and a drag flick in a motion analysis laboratory with an 18-camera three-dimensional motion analysis system and a calibrated multichannel force platform to examine differences in lower limb and lumbar kinematics and kinetics. Results revealed that drag flicks were performed with more of a forward lunge on the left lower limb resulting in significantly greater left ankle dorsiflexion, knee, hip and lumbar flexion (Ps<0.001) compared to a hit. Drag flicks were also performed with significantly greater lateral flexion (P < 0.002) and rotation of the lumbar spine (P < 0.006) compared to a hit. Differences in kinematics lead to greater shear, compression and tensile forces in multiple left lower limb and lumbar joints in the drag flick compared to the hit (P < 0.05). The biomechanical differences in drag flicks compared to a hit may have ramifications with respect to injury in field hockey drag flickers.
Decoding of top-down cognitive processing for SSVEP-controlled BMI
NASA Astrophysics Data System (ADS)
Min, Byoung-Kyong; Dähne, Sven; Ahn, Min-Hee; Noh, Yung-Kyun; Müller, Klaus-Robert
2016-11-01
We present a fast and accurate non-invasive brain-machine interface (BMI) based on demodulating steady-state visual evoked potentials (SSVEPs) in electroencephalography (EEG). Our study reports an SSVEP-BMI that, for the first time, decodes primarily based on top-down and not bottom-up visual information processing. The experimental setup presents a grid-shaped flickering line array that the participants observe while intentionally attending to a subset of flickering lines representing the shape of a letter. While the flickering pixels stimulate the participant’s visual cortex uniformly with equal probability, the participant’s intention groups the strokes and thus perceives a ‘letter Gestalt’. We observed decoding accuracy of 35.81% (up to 65.83%) with a regularized linear discriminant analysis; on average 2.05-fold, and up to 3.77-fold greater than chance levels in multi-class classification. Compared to the EEG signals, an electrooculogram (EOG) did not significantly contribute to decoding accuracies. Further analysis reveals that the top-down SSVEP paradigm shows the most focalised activation pattern around occipital visual areas; Granger causality analysis consistently revealed prefrontal top-down control over early visual processing. Taken together, the present paradigm provides the first neurophysiological evidence for the top-down SSVEP BMI paradigm, which potentially enables multi-class intentional control of EEG-BMIs without using gaze-shifting.
Fujisawa, Junya; Touyama, Hideaki; Hirose, Michitaka
2008-01-01
In this paper, alpha band modulation during visual spatial attention without visual stimuli was focused. Visual spatial attention has been expected to provide a new channel of non-invasive independent brain computer interface (BCI), but little work has been done on the new interfacing method. The flickering stimuli used in previous work cause a decline of independency and have difficulties in a practical use. Therefore we investigated whether visual spatial attention could be detected without such stimuli. Further, the common spatial patterns (CSP) were for the first time applied to the brain states during visual spatial attention. The performance evaluation was based on three brain states of left, right and center direction attention. The 30-channel scalp electroencephalographic (EEG) signals over occipital cortex were recorded for five subjects. Without CSP, the analyses made 66.44 (range 55.42 to 72.27) % of average classification performance in discriminating left and right attention classes. With CSP, the averaged classification accuracy was 75.39 (range 63.75 to 86.13) %. It is suggested that CSP is useful in the context of visual spatial attention, and the alpha band modulation during visual spatial attention without flickering stimuli has the possibility of a new channel for independent BCI as well as motor imagery.
Sensor Research Targets Smart Building Technology Using Radio-Frequency
a battery-free radio-frequency identification (RFID) sensor network with spatiotemporal pattern network based data fusion system for human presence sensing, with ARPA-E awarding the team $2 million over
Neural strategies for selective attention distinguish fast-action video game players.
Krishnan, Lavanya; Kang, Albert; Sperling, George; Srinivasan, Ramesh
2013-01-01
We investigated the psychophysical and neurophysiological differences between fast-action video game players (specifically first person shooter players, FPS) and non-action players (role-playing game players, RPG) in a visual search task. We measured both successful detections (hit rates) and steady-state visually evoked EEG potentials (SSVEPs). Search difficulty was varied along two dimensions: number of adjacent attended and ignored regions (1, 2 and 4), and presentation rate of novel search arrays (3, 8.6 and 20 Hz). Hit rates decreased with increasing presentation rates and number of regions, with the FPS players performing on average better than the RPG players. The largest differences in hit rate, between groups, occurred when four regions were simultaneously attended. We computed signal-to-noise ratio (SNR) of SSVEPs and used partial least squares regression to model hit rates, SNRs and their relationship at 3 Hz and 8.6 Hz. The following are the most significant results: RPG players' parietal responses to the attended 8.6 Hz flicker were predictive of hit rate and were positively correlated with it, indicating attentional signal enhancement. FPS players' parietal responses to the ignored 3 Hz flicker were predictive of hit rate and were positively correlated with it, indicating distractor suppression. Consistent with these parietal responses, RPG players' frontal responses to the attended 8.6 Hz flicker, increased as task difficulty increased with number of regions; FPS players' frontal responses to the ignored 3 Hz flicker increased with number of regions. Thus the FPS players appear to employ an active suppression mechanism to deploy selective attention simultaneously to multiple interleaved regions, while RPG primarily use signal enhancement. These results suggest that fast-action gaming can affect neural strategies and the corresponding networks underlying attention, presumably by training mechanisms of distractor suppression.
Debelić, Vladimir; Drnovšek Olup, Brigita; Žižek, Bogomir; Skitek, Milan; Jerin, Aleš
2016-01-01
Aim To determine whether higher glucose level and systemic oxidative stress decrease mean velocity (MV) index of the central retinal artery (CRA) during flickering light stimulation in type 1 diabetes (T1D). Methods The study was performed in the period from 2008 to 2015 at the University Eye Clinic in Ljubljana. 41 patients with T1D and 37 participants without diabetes were included. MV in the CRA was measured using Doppler ultrasound diagnostics in basal conditions and during 8 Hz flickering light irritation. The plasma levels of glucose, fructosamine, 8-hydroxy-2'-deoxyguanosine (8-OHdG), triglycerides, cholesterol, and low-density lipoprotein (LDL) were measured. Results Patients with T1D had significantly higher levels of blood glucose (P < 0.001), fructosamine (P < 0.001), and 8-OHdG (P < 0.001), but there were no significant differences in triglycerides (P = 0.108), cholesterol (P = 0.531), and LDL (P = 0.645) between the groups. Patients with T1D also had a significantly lower MV index in the CRA (1.11 ± 0.15 vs 1.24 ± 0.23; P = 0.010). In the T1D group, a significant negative correlation was found between the level of glucose (r = −0.58; P < 0.001), fructosamine (r = −0.46; P = 0.003), 8-OHdG (r = −0.48; P = 0.002) and the MV index in the CRA. At the same time, in this group fructosamine and 8-OHdG levels had a separate effect on the MV index (adjusted R2 = 0.38, P < 0.001). Conclusion Higher glucose levels, the medium-term glucose level, and systemic oxidative stress could importantly reduce retinal vasodilatation during flickering light irritation in patients with T1D. PMID:27815934
A flexible spatiotemporal method for fusing satellite images with different resolutions
Xiaolin Zhu; Eileen H. Helmer; Feng Gao; Desheng Liu; Jin Chen; Michael A. Lefsky
2016-01-01
Studies of land surface dynamics in heterogeneous landscapes often require remote sensing datawith high acquisition frequency and high spatial resolution. However, no single sensor meets this requirement. This study presents a new spatiotemporal data fusion method, the Flexible Spatiotemporal DAta Fusion (FSDAF) method, to generate synthesized frequent high spatial...
Development progresses of radio frequency ion source for neutral beam injector in fusion devices.
Chang, D H; Jeong, S H; Kim, T S; Park, M; Lee, K W; In, S R
2014-02-01
A large-area RF (radio frequency)-driven ion source is being developed in Germany for the heating and current drive of an ITER device. Negative hydrogen ion sources are the major components of neutral beam injection systems in future large-scale fusion experiments such as ITER and DEMO. RF ion sources for the production of positive hydrogen (deuterium) ions have been successfully developed for the neutral beam heating systems at IPP (Max-Planck-Institute for Plasma Physics) in Germany. The first long-pulse ion source has been developed successfully with a magnetic bucket plasma generator including a filament heating structure for the first NBI system of the KSTAR tokamak. There is a development plan for an RF ion source at KAERI to extract the positive ions, which can be applied for the KSTAR NBI system and to extract the negative ions for future fusion devices such as the Fusion Neutron Source and Korea-DEMO. The characteristics of RF-driven plasmas and the uniformity of the plasma parameters in the test-RF ion source were investigated initially using an electrostatic probe.
Telomeres and mechanisms of Robertsonian fusion.
Slijepcevic, P
1998-05-01
The Robertsonian (Rb) fusion, a chromosome rearrangement involving centric fusion of two acro-(telo)centric chromosomes to form a single metacentric, is one of the most frequent events in mammalian karyotype evolution. Since one of the functions of telomeres is to preserve chromosome integrity, a prerequisite for the formation of Rb fusions should be either telomere loss or telomere inactivation. Possible mechanisms underlying the formation of various types of Rb fusion are discussed here. For example, Rb fusion in wild mice involves complete loss of p-arm telomeres by chromosome breakage within minor satellite sequences. By contrast, interstitial telomeric sites are found in the pericentromeric regions of chromosomes originating from a number of vertebrate species, suggesting the occurrence of Rb-like fusion without loss of telomeres, a possibility consistent with some form of telomere inactivation. Finally, a recent study suggests that telomere shortening induced by the deletion of the telomerase RNA gene in the mouse germ-line leads to telomere loss and high frequencies of Rb fusion in mouse somatic cells. Thus, at least three mechanisms in mammalian cells lead to the formation of Rb fusions.
Non-linearity of visual evoked potentials in cerveau isolé and midpontine pretrigeminal cats.
Shibagaki, M; Kiyono, S; Kawashima, T; Watanabe, S
1985-01-01
Characteristics of the visual evoked responses to the flickering flash stimulation were studied in the cerveau isolé and midpontine pretrigeminal cats. The flash stimulation frequency was changed stepwise between 1 and 30 Hz in increasing and decreasing order. In all cases of both preparations, with drawing of fixed sweep speed of 200 msec in whole length, P1 and N1 latencies in the successive response slightly prolonged progressively 1 to about 20 Hz and thereafter shortened about 20-30 Hz stimulus frequencies in the course of the increasing phase, and vice versa in the course of the decreasing phase. Moreover, no difference in each latency (P1, N1, P2, N2) was found at the same stimulus frequency during increasing and decreasing phases. In the amplitude taken from the P1-N1 component, the peak was found in 5-9 Hz frequency bands. This peak was higher during the decreasing phase than during the increasing phase, which indicated a hysteresis phenomenon. A peak of power for the 1st harmonics was found at 3-6 Hz driving frequency bands, and that of the 2nd harmonics at 6-10 Hz. In the state without flash stimulus, no peaks or valleys in the power spectrum were found in specific frequencies, for example 3-10 Hz. The peak in the amplitude and that in the power spectrum at 3-10 Hz stimulus frequency bands suggested an entrainment phenomenon induced by forced oscillation. The phenomena of entrainment and hysteresis suggest the existence of a non-linear structure in the oscillation generating systems of visual evoked response.
Muscatello, Christopher M.; Domier, Calvin W.; Hu, Xing; ...
2014-08-13
Here, quasi-optical imaging at sub-THz frequencies has had a major impact on fusion plasma diagnostics. Mm-wave imaging reflectometry utilizes microwaves to actively probe fusion plasmas, inferring the local properties of electron density fluctuations. Electron cyclotron emission imaging is a multichannel radiometer that passively measures the spontaneous emission of microwaves from the plasma to infer local properties of electron temperature fluctuations. These imaging diagnostics work together to diagnose the characteristics of turbulence. Important quantities such as amplitude and wavenumber of coherent fluctuations, correlation lengths and decor relation times of turbulence, and poloidal flow velocity of the plasma are readily inferred.
THEORY AND MEASUREMENT OF VISUAL MECHANISMS
Crozier, W. J.; Wolf, Ernst
1944-01-01
Flicker contours for a square image of 3° visual angle, centered 6° on the temporal side of the fovea, the light sectored at a focus, are strikingly modified if the same illuminated area is arranged in four squares separated by a narrow opaque cross. The "cone" curves are made much steeper, and their abscissae of inflection (τ' are at higher intensities; Fmax. is not greatly changed, but alters less with change of light-time fraction in the flash cycle (tL). This modification is accompanied by a great enlargement of the scotopic segment of the duplex curves, consistent with the theory of the integrative relations of neural effects in the two groups of units involved. The changes are not consistent with the view that flicker end-points are determined by the activation of retinal cells with a fixed spatial distribution of invariable thresholds. At tL = 0.50 the 3° subdivided area gives very nearly the same contour as does a square 6° x 6°, with the same total perimeter of light-dark separation; the "edge effect" thus suggested is complicated by differences in the dependence of Fmax. and τ' upon tL. When an image pattern is produced by a grid of light bars separated by equally broad opaque spaces (10° x 10° over-all, centered at the fovea), the photopic flicker contours are made very steep and their midpoints are situated at quite low intensities, while the "rod" contribution tends to be more completely fused with the "cone" than is found for fields not subdivided. However, instead of a progressive increase of τ' with tL the curves for tL = 0.75 and 0.90 lie respectively below that for tL = 0.25 and 0.50 for a field of four broader stripes (1.43°) and both are below tL = 0.25 for a field of seven narrower stripes (0.77°). These latter changes are discussed in terms of the participation of subsidiary phenomena involving so called "γ movement." It is pointed out that since in these data σ1/Im is for each set of conditions a statistically constant quantity with a characteristic breadth of scatter σσ, it is possible to calculate a "coefficient of internal correlation" r which is a function of the conditions (as: image area, location, wave length of light, structure of image, light-time fraction) and which describes a property of any entire contour. The changes in r, as a function of the conditions of flicker excitation, reflect changes in the neural organization responsible for the liminal discrimination of flicker. It is shown that as consequence of simple changes in the image field, three parameters, as of the probability summation, are required for the description of a simplex flicker contour—since each of these is independently modifiable as to its magnitude and in its dependence on the light-time fraction. Subdivision of the image, with light sectored at a focus, produces in part only the changes in the flicker contour which we have earlier labelled the "pecten effect." In the latter, with light not sectored at a focus but with bar images moving across a field with inclined fixed opaque bars, the "cone" slope (dF/d log I) is sharply increased for tL > 0.50, but not below tL = 0.50, and the value of τ' is much less than it "should be." Consequently, the change in contrast brought about by the moving contact of light/dark borders is the significant factor in the "pecten effect," not simply pulsatile interruption of the light. PMID:19873392
NASA Astrophysics Data System (ADS)
Ai, Yan-Ting; Guan, Jiao-Yue; Fei, Cheng-Wei; Tian, Jing; Zhang, Feng-Ling
2017-05-01
To monitor rolling bearing operating status with casings in real time efficiently and accurately, a fusion method based on n-dimensional characteristic parameters distance (n-DCPD) was proposed for rolling bearing fault diagnosis with two types of signals including vibration signal and acoustic emission signals. The n-DCPD was investigated based on four information entropies (singular spectrum entropy in time domain, power spectrum entropy in frequency domain, wavelet space characteristic spectrum entropy and wavelet energy spectrum entropy in time-frequency domain) and the basic thought of fusion information entropy fault diagnosis method with n-DCPD was given. Through rotor simulation test rig, the vibration and acoustic emission signals of six rolling bearing faults (ball fault, inner race fault, outer race fault, inner-ball faults, inner-outer faults and normal) are collected under different operation conditions with the emphasis on the rotation speed from 800 rpm to 2000 rpm. In the light of the proposed fusion information entropy method with n-DCPD, the diagnosis of rolling bearing faults was completed. The fault diagnosis results show that the fusion entropy method holds high precision in the recognition of rolling bearing faults. The efforts of this study provide a novel and useful methodology for the fault diagnosis of an aeroengine rolling bearing.
Staisloff, Hannah E; Lee, Daniel H; Aronoff, Justin M
2016-07-01
For bilateral cochlear implant users, the left and right arrays are typically not physically aligned, resulting in a degradation of binaural fusion, which can be detrimental to binaural abilities. Perceptually aligning the two arrays can be accomplished by disabling electrodes in one ear that do not have a perceptually corresponding electrode in the other side. However, disabling electrodes at the edges of the array will cause compression of the input frequency range into a smaller cochlear extent, which may result in reduced spectral resolution. An alternative approach to overcome this mismatch would be to only align one edge of the array. By aligning either only the apical or basal end of the arrays, fewer electrodes would be disabled, potentially causing less reduction in spectral resolution. The goal of this study was to determine the relative effect of aligning either the basal or apical end of the electrode with regards to binaural fusion. A vocoder was used to simulate cochlear implant listening conditions in normal hearing listeners. Speech signals were vocoded such that the two ears were either predominantly aligned at only the basal or apical end of the simulated arrays. The experiment was then repeated with a spectrally inverted vocoder to determine whether the detrimental effects on fusion were related to the spectral-temporal characteristics of the stimuli or the location in the cochlea where the misalignment occurred. In Experiment 1, aligning the basal portion of the simulated arrays led to significantly less binaural fusion than aligning the apical portions of the simulated array. However, when the input was spectrally inverted, aligning the apical portion of the simulated array led to significantly less binaural fusion than aligning the basal portions of the simulated arrays. These results suggest that, for speech, with its predominantly low frequency spectral-temporal modulations, it is more important to perceptually align the apical portion of the array to better preserve binaural fusion. By partially aligning these arrays, cochlear implant users could potentially increase their ability to fuse speech sounds presented to the two ears while maximizing spectral resolution. Copyright © 2016 Elsevier B.V. All rights reserved.
Evaluation of taste solutions by sensor fusion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kojima, Yohichiro; Sato, Eriko; Atobe, Masahiko
In our previous studies, properties of taste solutions were discriminated based on sound velocity and amplitude of ultrasonic waves propagating through the solutions. However, to make this method applicable to beverages which contain many taste substances, further studies are required. In this study, the waveform of an ultrasonic wave with frequency of approximately 5 MHz propagating through a solution was measured and subjected to frequency analysis. Further, taste sensors require various techniques of sensor fusion to effectively obtain chemical and physical parameter of taste solutions. A sensor fusion method of ultrasonic wave sensor and various sensors, such as the surfacemore » plasmon resonance (SPR) sensor, to estimate tastes were proposed and examined in this report. As a result, differences among pure water and two basic taste solutions were clearly observed as differences in their properties. Furthermore, a self-organizing neural network was applied to obtained data which were used to clarify the differences among solutions.« less
Fusion of spectral models for dynamic modeling of sEMG and skeletal muscle force.
Potluri, Chandrasekhar; Anugolu, Madhavi; Chiu, Steve; Urfer, Alex; Schoen, Marco P; Naidu, D Subbaram
2012-01-01
In this paper, we present a method of combining spectral models using a Kullback Information Criterion (KIC) data fusion algorithm. Surface Electromyographic (sEMG) signals and their corresponding skeletal muscle force signals are acquired from three sensors and pre-processed using a Half-Gaussian filter and a Chebyshev Type- II filter, respectively. Spectral models - Spectral Analysis (SPA), Empirical Transfer Function Estimate (ETFE), Spectral Analysis with Frequency Dependent Resolution (SPFRD) - are extracted from sEMG signals as input and skeletal muscle force as output signal. These signals are then employed in a System Identification (SI) routine to establish the dynamic models relating the input and output. After the individual models are extracted, the models are fused by a probability based KIC fusion algorithm. The results show that the SPFRD spectral models perform better than SPA and ETFE models in modeling the frequency content of the sEMG/skeletal muscle force data.
A quantitative assay for mitochondrial fusion using Renilla luciferase complementation
Huang, Huiyan; Choi, Seok-Yong; Frohman, Michael A.
2010-01-01
Mitochondria continuously undergo fusion and fission, the relative rates of which define their morphology. Large mitochondria produce energy more efficiently, whereas small mitochondria translocate better to subcellular sites where local production of ATP is acutely required. Mitochondrial fusion is currently assayed by fusing together cells expressing GFP or RFP in their mitochondria and then scoring the frequency of cells with yellow mitochondria (representing fused green and red mitochondria). However, this assay is labor-intensive and only semi-quantitative. We describe here a reporter system consisting of split fragments of Renilla luciferase and YFP fused to mitochondrial matrix-targeting sequences and to leucine zippers to trigger dimerization. The assay enables fusion to be quantitated both visually for individual cells and on a population level using chemiluminescence, laying the foundation for high throughput small molecule and RNAi screens for modulators of mitochondrial fusion. We use the assay to examine cytoskeletal roles in fusion progression. PMID:20488258
Control of mechanically activated polymersome fusion: Factors affecting fusion
Henderson, Ian M.; Paxton, Walter F.
2014-12-15
Previously we have studied the mechanically-activated fusion of extruded (200 nm) polymer vesicles into giant polymersomes using agitation in the presence of salt. In this study we have investigated several factors contributing to this phenomenon, including the effects of (i) polymer vesicle concentration, (ii) agitation speed and duration, and iii) variation of the salt and its concentration. It was found that increasing the concentration of the polymer dramatically increases the production of giant vesicles through the increased collisions of polymersomes. Our investigations also found that increasing the frequency of agitation increased the efficiency of fusion, though ultimately limited the sizemore » of vesicle which could be produced due to the high shear involved. Finally it was determined that salt-mediation of the fusion process was not limited to NaCl, but is instead a general effect facilitated by the presence of solvated ionic compounds, albeit with different salts initiating fusion at different concentration.« less
Interpretation of frequency sweeping of n=0 mode in JET
NASA Astrophysics Data System (ADS)
Berk, H. L.
2006-04-01
Persistent rapid up and down frequency chirping modes with a toroidal mode number of zero (n=0) are observed in the JET tokamak when energetic ions, in the range of several hundred keV, are created by high field side ion cyclotron resonance frequency heating. Fokker-Planck calculations demonstrate that the heating method enables the formation of an energetically inverted ion distribution which supplies the free energy for the ions to excite a global geodesic acoustic mode (GGAM). The large frequency shifts of this mode are attributed to the formation of phase space structures whose frequencies, which are locked to an ion orbit resonance frequency, are forced to continually shift so that energetic particle energy can be released to counterbalance the energy dissipation present in the background plasma. In collaboration with C.J. Boswell, MIT; D. Borba, A.C.A. Figueiredo, Center for Nuclear Fusion Association; T. Johnson, Alfven Laboratory, KTH; M.F.F. Nave, Center for Nuclear Fusion Association; S.D. Pinches, Max Planck Institute for Plasma Physics; S.E. Sharapov, UKEA Culham Science Centre; and T. Zhou, University of Texas at Austin.
Dynamic Stabilization of the Ablative Rayleigh-Taylor Instability for Heavy Ion Fusion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qin, Hong; Davidson, Ronald C.; Logan, B. Grant
2012-10-04
Dynamic stabilization of the ablative Rayleigh-Taylor instability of a heavy ion fusion target induced by a beam wobbling system is studied. Using a sharp-boundary model and Courant-Synder theory, it is shown, with an appropriately chosen modulation waveform, that the instability can be sta- bilized in certain parameter regimes. It is found that the stabilization e ect has a strong dependence on the modulation frequency and the waveform. Modulation with frequency comparable to the instability growth rate is the most e ective in terms of stabilizing the instability. A modulation with two frequency components can result in a reduction of themore » growth rate larger than the sum of that due to the two components when applied separately.« less
Tracking the allocation of attention using human pupillary oscillations
Naber, Marnix; Alvarez, George A.; Nakayama, Ken
2013-01-01
The muscles that control the pupil are richly innervated by the autonomic nervous system. While there are central pathways that drive pupil dilations in relation to arousal, there is no anatomical evidence that cortical centers involved with visual selective attention innervate the pupil. In this study, we show that such connections must exist. Specifically, we demonstrate a novel Pupil Frequency Tagging (PFT) method, where oscillatory changes in stimulus brightness over time are mirrored by pupil constrictions and dilations. We find that the luminance–induced pupil oscillations are enhanced when covert attention is directed to the flicker stimulus and when targets are correctly detected in an attentional tracking task. These results suggest that the amplitudes of pupil responses closely follow the allocation of focal visual attention and the encoding of stimuli. PFT provides a new opportunity to study top–down visual attention itself as well as identifying the pathways and mechanisms that support this unexpected phenomenon. PMID:24368904
A new approach for SSVEP detection using PARAFAC and canonical correlation analysis.
Tello, Richard; Pouryazdian, Saeed; Ferreira, Andre; Beheshti, Soosan; Krishnan, Sridhar; Bastos, Teodiano
2015-01-01
This paper presents a new way for automatic detection of SSVEPs through correlation analysis between tensor models. 3-way EEG tensor of channel × frequency × time is decomposed into constituting factor matrices using PARAFAC model. PARAFAC analysis of EEG tensor enables us to decompose multichannel EEG into constituting temporal, spectral and spatial signatures. SSVEPs characterized with localized spectral and spatial signatures are then detected exploiting a correlation analysis between extracted signatures of the EEG tensor and the corresponding simulated signatures of all target SSVEP signals. The SSVEP that has the highest correlation is selected as the intended target. Two flickers blinking at 8 and 13 Hz were used as visual stimuli and the detection was performed based on data packets of 1 second without overlapping. Five subjects participated in the experiments and the highest classification rate of 83.34% was achieved, leading to the Information Transfer Rate (ITR) of 21.01 bits/min.
Binaural fusion and the representation of virtual pitch in the human auditory cortex.
Pantev, C; Elbert, T; Ross, B; Eulitz, C; Terhardt, E
1996-10-01
The auditory system derives the pitch of complex tones from the tone's harmonics. Research in psychoacoustics predicted that binaural fusion was an important feature of pitch processing. Based on neuromagnetic human data, the first neurophysiological confirmation of binaural fusion in hearing is presented. The centre of activation within the cortical tonotopic map corresponds to the location of the perceived pitch and not to the locations that are activated when the single frequency constituents are presented. This is also true when the different harmonics of a complex tone are presented dichotically. We conclude that the pitch processor includes binaural fusion to determine the particular pitch location which is activated in the auditory cortex.
Photometric Evidence for a Disc-Jet Connection in CH Cygni
NASA Astrophysics Data System (ADS)
Sokoloski, J. L.; Kenyon, S. J.
2001-12-01
We describe observations of the rapid optical variations of the symbiotic star CH Cygni on 12 nights between 1997 and 1999. The B-band differential light curves reveal an incredible diversity of flickering behavior, from large-amplitude (up to 0.5 mag) variations with a power-law power spectrum, to lower amplitude (0.1 mag) variations with both power-law and non-power-law power spectra, to the complete absence of rapid variations down to a level of mmag. The series of light curves from observations in 1997/1998 exhibit an evolution from smooth, low-amplitude variations, to high-amplitude flickering with power at all measurable time scales. This evolution may be showing us the re-creation of the inner accretion disc after its disruption in association with the jet that was produced in early 1997 (Karovska et al. 1998). We do not find any evidence for quasi-periodic oscillations in the power spectra of individual light curves, and we believe the instances in which flickering completely disappeared coincide with eclipse of the white dwarf and accretion disc. We discuss the implications of our results for magnetic propeller models of this system, as well as compare CH Cygni to other systems where disc-jet connections have been proposed, such as the Galactic microquasar GRS 1915+105. This work was funded in part by NSF grant INT-9902665 to J.L.S.
Voicescu, Sonia A; Michaud, David S; Feder, Katya; Marro, Leonora; Than, John; Guay, Mireille; Denning, Allison; Bower, Tara; van den Berg, Frits; Broner, Norm; Lavigne, Eric
2016-03-01
The Community Noise and Health Study conducted by Health Canada included randomly selected participants aged 18-79 yrs (606 males, 632 females, response rate 78.9%), living between 0.25 and 11.22 km from operational wind turbines. Annoyance to wind turbine noise (WTN) and other features, including shadow flicker (SF) was assessed. The current analysis reports on the degree to which estimating high annoyance to wind turbine shadow flicker (HAWTSF) was improved when variables known to be related to WTN exposure were also considered. As SF exposure increased [calculated as maximum minutes per day (SFm)], HAWTSF increased from 3.8% at 0 ≤ SFm < 10 to 21.1% at SFm ≥ 30, p < 0.0001. For each unit increase in SFm the odds ratio was 2.02 [95% confidence interval: (1.68,2.43)]. Stepwise regression models for HAWTSF had a predictive strength of up to 53% with 10% attributed to SFm. Variables associated with HAWTSF included, but were not limited to, annoyance to other wind turbine-related features, concern for physical safety, and noise sensitivity. Reported dizziness was also retained in the final model at p = 0.0581. Study findings add to the growing science base in this area and may be helpful in identifying factors associated with community reactions to SF exposure from wind turbines.
Palkovits, Stefan; Lasta, Michael; Told, Reinhard; Schmidl, Doreen; Werkmeister, René; Cherecheanu, Alina Popa; Garhöfer, Gerhard; Schmetterer, Leopold
2015-01-01
Cerebral and retinal blood flow are dependent on local neuronal activity. Several studies quantified the increase in cerebral blood flow and oxygen consumption during activity. In the present study we investigated the relation between changes in retinal blood flow and oxygen extraction during stimulation with diffuse luminance flicker and the influence of breathing gas mixtures with different fractions of O2 (FiO2; 100% 15% and 12%). Twenty-four healthy subjects were included. Retinal blood flow was studied by combining measurement of vessel diameters using the Dynamic Vessel Analyser with measurements of blood velocity using laser Doppler velocimetry. Oxygen saturation was measured using spectroscopic reflectometry and oxygen extraction was calculated. Flicker stimulation increased retinal blood flow (57.7 ± 17.8%) and oxygen extraction (34.6 ± 24.1%; p < 0.001 each). During 100% oxygen breathing the response of retinal blood flow and oxygen extraction was increased (p < 0.01 each). By contrast, breathing gas mixtures with 12% and 15% FiO2 did not alter flicker–induced retinal haemodynamic changes. The present study indicates that at a comparable increase in blood flow the increase in oxygen extraction in the retina is larger than in the brain. During systemic hyperoxia the blood flow and oxygen extraction responses to neural stimulation are augmented. The underlying mechanism is unknown. PMID:26672758
Savitha, S; Sadhasivam, S; Swaminathan, K
2010-01-01
The fungal strains Graphium putredinis and Trichoderma harzianum were selected as parents for fusant development. Protoplasts were isolated using the combination of lysing enzymes Novozym 234 and cellulase with 0.6M KCl as osmotic stabilizer. The optimum conditions for release of viable protoplasts from the fungal mycelium viz. age of the mycelium, lytic enzymes, osmotic stabilizers, pH, incubation period and regeneration medium were determined. Intergeneric protoplast fusion was carried out using 50% polyethylene glycol with calcium chloride (CaCl(2)) and glycine buffer and the conditions for effective protoplast fusion, viz. fusogen, osmotic stabilizer, pH, incubation period and regeneration medium were optimized. At optimum conditions, the regeneration frequency of the fused protoplasts on potato dextrose agar (PDA) medium and fusion frequency were calculated. The regeneration frequency on non-selective (PDA) and selective media (PDA amended with starch) was determined for the parental and fusant strains in which, fusant showed a higher rate of regeneration. Fusant formation was confirmed by morphological markers (colony morphology and spore size and shape) and genetical markers like, mycelial protein pattern, restriction digestion pattern and random amplified polymorphic DNA (RAPD) analysis. The efficiency of these parental strains and their intergeneric fusant in the production of hydrolytic enzymes - amylases (treatment plant for sago factory effluent), cellulases (bioethanol), xylanases (bleaching agents for waste paper pulp) and proteases (additives in commercial detergents) - have probable applications in various industrial processes. (c) 2010 Elsevier Inc. All rights reserved.
Distinct roles for key karyogamy proteins during yeast nuclear fusion.
Melloy, Patricia; Shen, Shu; White, Erin; Rose, Mark D
2009-09-01
During yeast mating, cell fusion is followed by the congression and fusion of the two nuclei. Proteins required for nuclear fusion are found at the surface (Prm3p) and within the lumen (Kar2p, Kar5p, and Kar8p) of the nuclear envelope (NE). Electron tomography (ET) of zygotes revealed that mutations in these proteins block nuclear fusion with different morphologies, suggesting that they act in different steps of fusion. Specifically, prm3 zygotes were blocked before formation of membrane bridges, whereas kar2, kar5, and kar8 zygotes frequently contained them. Membrane bridges were significantly larger and occurred more frequently in kar2 and kar8, than in kar5 mutant zygotes. The kinetics of NE fusion in prm3, kar5, and kar8 mutants, measured by live-cell fluorescence microscopy, were well correlated with the size and frequency of bridges observed by ET. However the kar2 mutant was defective for transfer of NE lumenal GFP, but not diffusion within the lumen, suggesting that transfer was blocked at the NE fusion junction. These observations suggest that Prm3p acts before initiation of outer NE fusion, Kar5p may help dilation of the initial fusion pore, and Kar2p and Kar8p act after outer NE fusion, during inner NE fusion.
Binaural pitch fusion: Comparison of normal-hearing and hearing-impaired listenersa)
Reiss, Lina A. J.; Shayman, Corey S.; Walker, Emily P.; Bennett, Keri O.; Fowler, Jennifer R.; Hartling, Curtis L.; Glickman, Bess; Lasarev, Michael R.; Oh, Yonghee
2017-01-01
Binaural pitch fusion is the fusion of dichotically presented tones that evoke different pitches between the ears. In normal-hearing (NH) listeners, the frequency range over which binaural pitch fusion occurs is usually <0.2 octaves. Recently, broad fusion ranges of 1–4 octaves were demonstrated in bimodal cochlear implant users. In the current study, it was hypothesized that hearing aid (HA) users would also exhibit broad fusion. Fusion ranges were measured in both NH and hearing-impaired (HI) listeners with hearing losses ranging from mild-moderate to severe-profound, and relationships of fusion range with demographic factors and with diplacusis were examined. Fusion ranges of NH and HI listeners averaged 0.17 ± 0.13 octaves and 1.7 ± 1.5 octaves, respectively. In HI listeners, fusion ranges were positively correlated with a principal component measure of the covarying factors of young age, early age of hearing loss onset, and long durations of hearing loss and HA use, but not with hearing threshold, amplification level, or diplacusis. In NH listeners, no correlations were observed with age, hearing threshold, or diplacusis. The association of broad fusion with early onset, long duration of hearing loss suggests a possible role of long-term experience with hearing loss and amplification in the development of broad fusion. PMID:28372056
An independent brain-computer interface using covert non-spatial visual selective attention
NASA Astrophysics Data System (ADS)
Zhang, Dan; Maye, Alexander; Gao, Xiaorong; Hong, Bo; Engel, Andreas K.; Gao, Shangkai
2010-02-01
In this paper, a novel independent brain-computer interface (BCI) system based on covert non-spatial visual selective attention of two superimposed illusory surfaces is described. Perception of two superimposed surfaces was induced by two sets of dots with different colors rotating in opposite directions. The surfaces flickered at different frequencies and elicited distinguishable steady-state visual evoked potentials (SSVEPs) over parietal and occipital areas of the brain. By selectively attending to one of the two surfaces, the SSVEP amplitude at the corresponding frequency was enhanced. An online BCI system utilizing the attentional modulation of SSVEP was implemented and a 3-day online training program with healthy subjects was carried out. The study was conducted with Chinese subjects at Tsinghua University, and German subjects at University Medical Center Hamburg-Eppendorf (UKE) using identical stimulation software and equivalent technical setup. A general improvement of control accuracy with training was observed in 8 out of 18 subjects. An averaged online classification accuracy of 72.6 ± 16.1% was achieved on the last training day. The system renders SSVEP-based BCI paradigms possible for paralyzed patients with substantial head or ocular motor impairments by employing covert attention shifts instead of changing gaze direction.
Accounting for phase drifts in SSVEP-based BCIs by means of biphasic stimulation.
Wu, Hung-Yi; Lee, Po-Lei; Chang, Hsiang-Chih; Hsieh, Jen-Chuen
2011-05-01
This study proposes a novel biphasic stimulation technique to solve the issue of phase drifts in steady-state visual evoked potential (SSVEPs) in phase-tagged systems. Phase calibration was embedded in stimulus sequences using a biphasic flicker, which is driven by a sequence with alternating reference and phase-shift states. Nine subjects were recruited to participate in off-line and online tests. Signals were bandpass filtered and segmented by trigger signals into reference and phase-shift epochs. Frequency components of SSVEP in the reference and phase-shift epochs were extracted using the Fourier method with a 50% overlapped sliding window. The real and imaginary parts of the SSVEP frequency components were organized into complex vectors in each epoch. Hotelling's t-square test was used to determine the significances of nonzero mean vectors. The rejection of noisy data segments and the validation of gaze detections were made based on p values. The phase difference between the valid mean vectors of reference and phase-shift epochs was used to identify user's gazed targets in this system. Data showed an average information transfer rate of 44.55 and 38.21 bits/min in off-line and online tests, respectively. © 2011 IEEE
Detection of briefly flashed sine-gratings in dark-adapted vision.
Hofmann, M I; Barnes, C S; Hallett, P E
1990-01-01
Scotopic contrast sensitivity was measured near 20 deg retinal eccentricity for briefly flashed (10 or 20 msec) sine-wave gratings presented in darkness to dark-adapted subjects. For very low spatial frequencies (0.2-0.5 c/deg), curves of contrast sensitivity vs luminous energy show evidence of a low rod plateau and a high scotopic region, with an intervening transition at around -2 to -2.5 log scot td sec. Similar measurements made using long flashed or flickering gratings do not show a plateau. The results suggest that vision in the low rod region is impaired for brief flashes. For the briefly flashed stimuli, curves of contrast sensitivity versus spatial frequency in the low region were best fit by simple Gaussian functions with a variable centre size (sigma c = 0.5----0.25 deg), size decreasing with increasing flash energy. Difference-of-Gaussian functions with constant centre size (sigma c = 0.25 deg) provided the best fit in the high region. Overt input from the cones and grating area artefacts are excluded by appropriate tests. Calculation of photon flux into the receptive field centres suggests that signal compression in P alpha ganglion cells contributes to the low rod plateau.
An independent brain-computer interface using covert non-spatial visual selective attention.
Zhang, Dan; Maye, Alexander; Gao, Xiaorong; Hong, Bo; Engel, Andreas K; Gao, Shangkai
2010-02-01
In this paper, a novel independent brain-computer interface (BCI) system based on covert non-spatial visual selective attention of two superimposed illusory surfaces is described. Perception of two superimposed surfaces was induced by two sets of dots with different colors rotating in opposite directions. The surfaces flickered at different frequencies and elicited distinguishable steady-state visual evoked potentials (SSVEPs) over parietal and occipital areas of the brain. By selectively attending to one of the two surfaces, the SSVEP amplitude at the corresponding frequency was enhanced. An online BCI system utilizing the attentional modulation of SSVEP was implemented and a 3-day online training program with healthy subjects was carried out. The study was conducted with Chinese subjects at Tsinghua University, and German subjects at University Medical Center Hamburg-Eppendorf (UKE) using identical stimulation software and equivalent technical setup. A general improvement of control accuracy with training was observed in 8 out of 18 subjects. An averaged online classification accuracy of 72.6 +/- 16.1% was achieved on the last training day. The system renders SSVEP-based BCI paradigms possible for paralyzed patients with substantial head or ocular motor impairments by employing covert attention shifts instead of changing gaze direction.
... to the touch and lights that flicker. Portable Space Heaters Keep combustible objects at least three feet ... Radiological Dispersion Device Severe Weather Snowstorms & Extreme Cold Space Weather Thunderstorms & Lightning Tornadoes Tsunamis Volcanoes Wildfires Ready. ...
[Perceptual sharpness metric for visible and infrared color fusion images].
Gao, Shao-Shu; Jin, Wei-Qi; Wang, Xia; Wang, Ling-Xue; Luo, Yuan
2012-12-01
For visible and infrared color fusion images, objective sharpness assessment model is proposed to measure the clarity of detail and edge definition of the fusion image. Firstly, the contrast sensitivity functions (CSF) of the human visual system is used to reduce insensitive frequency components under certain viewing conditions. Secondly, perceptual contrast model, which takes human luminance masking effect into account, is proposed based on local band-limited contrast model. Finally, the perceptual contrast is calculated in the region of interest (contains image details and edges) in the fusion image to evaluate image perceptual sharpness. Experimental results show that the proposed perceptual sharpness metrics provides better predictions, which are more closely matched to human perceptual evaluations, than five existing sharpness (blur) metrics for color images. The proposed perceptual sharpness metrics can evaluate the perceptual sharpness for color fusion images effectively.
Patil, N S; Patil, S M; Govindwar, S P; Jadhav, J P
2015-02-01
Protoplast fusion between Aspergillus oryzae and Trichoderma harzianum and application of fusant in degradation of shellfish waste. The filamentous chitinolytic fungal strains A. oryzae NCIM 1272 and T. harzianum NCIM 1185 were selected as parents for protoplast fusion. Viable protoplasts were released from fungal mycelium using enzyme cocktail containing 5 mg ml(-1) lysing enzymes from T. harzianum, 0.06 mg ml(-1) β-glucuronidase from Helix pomatia and 1 mg ml(-1) purified Penicillium ochrochloron chitinase in 0.8 mol l(-1) sorbitol as an osmotic stabilizer. Intergeneric protoplast fusion was carried out using 60% polyethylene glycol as a fusogen. At optimum conditions, the regeneration frequency of the fused protoplasts on colloidal chitin medium and fusion frequency were calculated. Fusant showed higher rate of growth pattern, chitinase activity and protein content than parents. Fusant formation was confirmed by morphological markers, viz. colony morphology and spore size and denaturation gradient gel electrophoresis (DGGE). This study revealed protoplast fusion between A. oryzae and T. harzianum significantly enhanced chitinase activity which ultimately provides potential strain for degradation of shellfish waste. Consistency in the molecular characterization results using DGGE is the major outcome of this study which can be emerged as a fundamental step in fusant identification. Now it is need to provide attention over effective chitin degradation to manage shrimp processing issues. In this aspect, ability of fusant to degrade shellfish waste efficiently in short incubation time revealed discovery of potential strain in the reclamation of seafood processing crustacean bio-waste. © 2014 The Society for Applied Microbiology.
NASA Astrophysics Data System (ADS)
Wang, Mi; Fang, Chengcheng; Yang, Bo; Cheng, Yufeng
2016-06-01
The low frequency error is a key factor which has affected uncontrolled geometry processing accuracy of the high-resolution optical image. To guarantee the geometric quality of imagery, this paper presents an on-orbit calibration method for the low frequency error based on geometric calibration field. Firstly, we introduce the overall flow of low frequency error on-orbit analysis and calibration, which includes optical axis angle variation detection of star sensor, relative calibration among star sensors, multi-star sensor information fusion, low frequency error model construction and verification. Secondly, we use optical axis angle change detection method to analyze the law of low frequency error variation. Thirdly, we respectively use the method of relative calibration and information fusion among star sensors to realize the datum unity and high precision attitude output. Finally, we realize the low frequency error model construction and optimal estimation of model parameters based on DEM/DOM of geometric calibration field. To evaluate the performance of the proposed calibration method, a certain type satellite's real data is used. Test results demonstrate that the calibration model in this paper can well describe the law of the low frequency error variation. The uncontrolled geometric positioning accuracy of the high-resolution optical image in the WGS-84 Coordinate Systems is obviously improved after the step-wise calibration.
2006-10-13
As Cassini watches the rings pass in front of bright red giant star Aldebaran, the star light fluctuates, providing information about the concentrations of ring particles within the various radial features in the rings
2006-10-11
As Cassini watches the rings pass in front of bright red giant star Aldebaran, the star light fluctuates, providing information about the concentrations of ring particles within the various radial features in the rings
... can be exacerbated by light sources such as computer screens or fluorescent lights. Use a flicker-free ... cubicle shield Allow frequent breaks from tasks involving computer Provide alternative light sources: Replace fluorescent lights with ...
Church, Alanna J; Calicchio, Monica L; Nardi, Valentina; Skalova, Alena; Pinto, Andre; Dillon, Deborah A; Gomez-Fernandez, Carmen R; Manoj, Namitha; Haimes, Josh D; Stahl, Joshua A; Dela Cruz, Filemon S; Tannenbaum-Dvir, Sarah; Glade-Bender, Julia L; Kung, Andrew L; DuBois, Steven G; Kozakewich, Harry P; Janeway, Katherine A; Perez-Atayde, Antonio R; Harris, Marian H
2018-03-01
Infantile fibrosarcoma and congenital mesoblastic nephroma are tumors of infancy traditionally associated with the ETV6-NTRK3 gene fusion. However, a number of case reports have identified variant fusions in these tumors. In order to assess the frequency of variant NTRK3 fusions, and in particular whether the recently identified EML4-NTRK3 fusion is recurrent, 63 archival cases of infantile fibrosarcoma, congenital mesoblastic nephroma, mammary analog secretory carcinoma and secretory breast carcinoma (tumor types that are known to carry recurrent ETV6-NTRK3 fusions) were tested with NTRK3 break-apart FISH, EML4-NTRK3 dual fusion FISH, and targeted RNA sequencing. The EML4-NTRK3 fusion was identified in two cases of infantile fibrosarcoma (one of which was previously described), and in one case of congenital mesoblastic nephroma, demonstrating that the EML4-NTRK3 fusion is a recurrent genetic event in these related tumors. The growing spectrum of gene fusions associated with infantile fibrosarcoma and congenital mesoblastic nephroma along with the recent availability of targeted therapies directed toward inhibition of NTRK signaling argue for alternate testing strategies beyond ETV6 break-apart FISH. The use of either NTRK3 FISH or next-generation sequencing will expand the number of cases in which an oncogenic fusion is identified and facilitate optimal diagnosis and treatment for patients.
Effects of ROCK inhibitor Y-27632 on cell fusion through a microslit.
Wada, Ken-Ichi; Hosokawa, Kazuo; Ito, Yoshihiro; Maeda, Mizuo
2015-11-01
We previously reported a direct cytoplasmic transfer method using a microfluidic device, in which cell fusion was induced through a microslit (slit-through-fusion) by the Sendai virus envelope (HVJ-E) to prevent nuclear mixing. However, the method was impractical due to low efficiency of slit-through-fusion formation and insufficient prevention of nuclear mixing. The purpose of this study was to establish an efficient method for inducing slit-through-fusion without nuclear mixing. We hypothesized that modulation of cytoskeletal component can decrease nuclear migration through the microslit considering its functions. Here we report that supplementation with Y-27632, a specific ROCK inhibitor, significantly enhances cell fusion induction and prevention of nuclear mixing. Supplementation with Y-27632 increased the formation of slit-through-fusion efficiency by more than twofold. Disruption of F-actin by Y-27632 prevented nuclear migration between fused cells through the microslit. These two effects of Y-27632 led to promotion of the slit-through-fusion without nuclear mixing with a 16.5-fold higher frequency compared to our previous method (i.e., cell fusion induction by HVJ-E without supplementation with Y-27632). We also confirmed that mitochondria were successfully transferred to the fusion partner under conditions of Y-27632 supplementation. These findings demonstrate the practicality of our cell fusion system in producing direct cytoplasmic transfer between live cells. © 2015 Wiley Periodicals, Inc.
2006-10-09
As Cassini watches the rings pass in front of the bright red giant star Aldebaran, the star light fluctuates, providing information about the concentrations of ring particles within the various radial features in the rings
Resource partitioning among woodpeckers in northeastern Oregon.
Bull Evelyn L.; Steven R. Peterson; Jack Ward. Thomas
1986-01-01
Eight species of woodpeckers coexist in conifer forests in northeastern Oregon: northern flicker (Colaptes auratus); yellow-bellied (Sphyrapicus varius) and Williamson's (S. thyroideus) sapsuckers; and pileated (Dryocopus pileatus), hairy (Picoides villosus),...
Retail Lamps Study 3.1: Dimming, Flicker, and Power Quality Characteristics of LED A Lamps
DOE Office of Scientific and Technical Information (OSTI.GOV)
Royer, Michael P.; Poplawski, Michael E.; Brown, Charles C.
2014-12-01
To date, all three reports in the retail lamps series have focused on basic performance parameters, such as lumen output, efficacy, and color quality. This report goes a step further, examining the photoelectric characteristics (i.e., dimming and flicker) of a subset of lamps from CALiPER Retails Lamps Study 3. Specifically, this report focuses on the dimming, power quality, and flicker characteristics of 14 LED A lamps, as controlled by four different retail-available dimmers. The results demonstrate notable variation across the various lamps, but little variation between the four dimmers. Overall, the LED lamps: ~tended to have higher relative light outputmore » compared to the incandescent and halogen benchmark at the same dimmer output signal (RMS voltage). The lamps’ dimming curves (i.e., the relationship between control signal and relative light output) ranged from linear to very similar to the square-law curve typical of an incandescent lamp. ~generally exhibited symmetrical behavior—the same dimming curve—when measured proceeding from maximum to minimum or minimum to maximum control signal. ~mostly dimmed below 10% of full light output, with some exceptions for specific lamp and dimmer combinations ~exhibited a range of flicker characteristics, with many comparing favorably to the level typical of a magnetically-ballasted fluorescent lamp through at least a majority of the dimming range. ~ always exceeded the relative (normalized) efficacy over the dimming range of the benchmark lamps, which rapidly decline in efficacy when they are dimmed. This report generally does not attempt to rank the performance of one product compared to another, but instead focuses on the collective performance of the group versus conventional incandescent or halogen lamps, the performance of which is likely to be the baseline for a majority of consumers. Undoubtedly, some LED lamps perform better—or more similar to conventional lamps—than others. Some perform desirably for one characteristic, but not others. Consumers (and specifiers) may have a hard time distinguishing better-performing lamps from one another; at this time, physical experimentation is likely the best evaluation tool.« less
A quantitative assay for mitochondrial fusion using Renilla luciferase complementation.
Huang, Huiyan; Choi, Seok-Yong; Frohman, Michael A
2010-08-01
Mitochondria continuously undergo fusion and fission, the relative rates of which define their morphology. Large mitochondria produce energy more efficiently, whereas small mitochondria translocate better to subcellular sites where local production of ATP is acutely required. Mitochondrial fusion is currently assayed by fusing together cells expressing GFP or RFP in their mitochondria and then scoring the frequency of cells with yellow mitochondria (representing fused green and red mitochondria). However, this assay is labor-intensive and only semi-quantitative. We describe here a reporter system consisting of split fragments of Renilla luciferase and YFP fused to mitochondrial matrix-targeting sequences and to leucine zippers to trigger dimerization. The assay enables fusion to be quantitated both visually for individual cells and on a population level using chemiluminescence, laying the foundation for high throughput small molecule and RNAi screens for modulators of mitochondrial fusion. We use the assay to examine cytoskeletal roles in fusion progression. (c) 2010 Mitochondria Research Society. Published by Elsevier B.V. All rights reserved.
Infrared and visible image fusion with spectral graph wavelet transform.
Yan, Xiang; Qin, Hanlin; Li, Jia; Zhou, Huixin; Zong, Jing-guo
2015-09-01
Infrared and visible image fusion technique is a popular topic in image analysis because it can integrate complementary information and obtain reliable and accurate description of scenes. Multiscale transform theory as a signal representation method is widely used in image fusion. In this paper, a novel infrared and visible image fusion method is proposed based on spectral graph wavelet transform (SGWT) and bilateral filter. The main novelty of this study is that SGWT is used for image fusion. On the one hand, source images are decomposed by SGWT in its transform domain. The proposed approach not only effectively preserves the details of different source images, but also excellently represents the irregular areas of the source images. On the other hand, a novel weighted average method based on bilateral filter is proposed to fuse low- and high-frequency subbands by taking advantage of spatial consistency of natural images. Experimental results demonstrate that the proposed method outperforms seven recently proposed image fusion methods in terms of both visual effect and objective evaluation metrics.
Hause, Anne M.; Henke, David M.; Avadhanula, Vasanthi; Shaw, Chad A.; Tapia, Lorena I.
2017-01-01
Background The fusion (F) protein of RSV is the major vaccine target. This protein undergoes a conformational change from pre-fusion to post-fusion. Both conformations share antigenic sites II and IV. Pre-fusion F has unique antigenic sites p27, ø, α2α3β3β4, and MPE8; whereas, post-fusion F has unique antigenic site I. Our objective was to determine the antigenic variability for RSV/A and RSV/B isolates from contemporary and historical genotypes compared to a historical RSV/A strain. Methods The F sequences of isolates from GenBank, Houston, and Chile (N = 1,090) were used for this analysis. Sequences were compared pair-wise to a reference sequence, a historical RSV/A Long strain. Variability (calculated as %) was defined as changes at each amino acid (aa) position when compared to the reference sequence. Only aa at antigenic sites with variability ≥5% were reported. Results A total of 1,090 sequences (822 RSV/A and 268 RSV/B) were analyzed. When compared to the reference F, those domains with the greatest number of non-synonymous changes included the signal peptide, p27, heptad repeat domain 2, antigenic site ø, and the transmembrane domain. RSV/A subgroup had 7 aa changes in the antigenic sites: site I (N = 1), II (N = 1), p27 (N = 4), α2α3β3β4(AM14) (N = 1), ranging in frequency from 7–91%. In comparison, RSV/B had 19 aa changes in antigenic sites: I (N = 3), II (N = 1), p27 (N = 9), ø (N = 4), α2α3β3β4(AM14) (N = 1), and MPE8 (N = 1), ranging in frequency from 79–100%. Discussion Although antigenic sites of RSV F are generally well conserved, differences are observed when comparing the two subgroups to the reference RSV/A Long strain. Further, these discrepancies are accented in the antigenic sites in pre-fusion F of RSV/B isolates, often occurring with a frequency of 100%. This could be of importance if a monovalent F protein from the historical GA1 genotype of RSV/A is used for vaccine development. PMID:28414749
Hause, Anne M; Henke, David M; Avadhanula, Vasanthi; Shaw, Chad A; Tapia, Lorena I; Piedra, Pedro A
2017-01-01
The fusion (F) protein of RSV is the major vaccine target. This protein undergoes a conformational change from pre-fusion to post-fusion. Both conformations share antigenic sites II and IV. Pre-fusion F has unique antigenic sites p27, ø, α2α3β3β4, and MPE8; whereas, post-fusion F has unique antigenic site I. Our objective was to determine the antigenic variability for RSV/A and RSV/B isolates from contemporary and historical genotypes compared to a historical RSV/A strain. The F sequences of isolates from GenBank, Houston, and Chile (N = 1,090) were used for this analysis. Sequences were compared pair-wise to a reference sequence, a historical RSV/A Long strain. Variability (calculated as %) was defined as changes at each amino acid (aa) position when compared to the reference sequence. Only aa at antigenic sites with variability ≥5% were reported. A total of 1,090 sequences (822 RSV/A and 268 RSV/B) were analyzed. When compared to the reference F, those domains with the greatest number of non-synonymous changes included the signal peptide, p27, heptad repeat domain 2, antigenic site ø, and the transmembrane domain. RSV/A subgroup had 7 aa changes in the antigenic sites: site I (N = 1), II (N = 1), p27 (N = 4), α2α3β3β4(AM14) (N = 1), ranging in frequency from 7-91%. In comparison, RSV/B had 19 aa changes in antigenic sites: I (N = 3), II (N = 1), p27 (N = 9), ø (N = 4), α2α3β3β4(AM14) (N = 1), and MPE8 (N = 1), ranging in frequency from 79-100%. Although antigenic sites of RSV F are generally well conserved, differences are observed when comparing the two subgroups to the reference RSV/A Long strain. Further, these discrepancies are accented in the antigenic sites in pre-fusion F of RSV/B isolates, often occurring with a frequency of 100%. This could be of importance if a monovalent F protein from the historical GA1 genotype of RSV/A is used for vaccine development.
Ryan, Bríd M; Wang, Yi; Jen, Jin; Yi, Eunhee S; Olivo-Marston, Susan; Yang, Ping; Harris, Curtis C
2014-07-01
The EML4-ALK fusion gene is more frequently found in younger, never smoking patients with lung cancer. Meanwhile, never smokers exposed to secondhand tobacco smoke (SHS) during childhood are diagnosed at a younger age compared with never smoking patients with lung cancer who are not exposed. We, therefore, hypothesized that SHS, which can induce DNA damage, is associated with the EML4-ALK fusion gene. We compared the frequency of the EML4-ALK fusion gene among 197 never smoker patients with lung cancer with and without a history of exposure to SHS during childhood at Mayo Clinic. The EML4-ALK fusion gene was detected in 33% of cases from never smokers with a history of SHS exposure during childhood, whereas 47% of never smoking lung cancer cases without a history of childhood SHS exposure tested positive for the fusion gene. The EML4-ALK fusion gene is not enriched in tumors from individuals exposed to SHS during childhood. These data suggest that childhood exposure to SHS is not a significant etiologic cause of the EML4-ALK fusion gene in lung cancer. ©2014 American Association for Cancer Research.
Kinase gene fusions in defined subsets of melanoma.
Turner, Jacqueline; Couts, Kasey; Sheren, Jamie; Saichaemchan, Siriwimon; Ariyawutyakorn, Witthawat; Avolio, Izabela; Cabral, Ethan; Glogowska, Magdelena; Amato, Carol; Robinson, Steven; Hintzsche, Jennifer; Applegate, Allison; Seelenfreund, Eric; Gonzalez, Rita; Wells, Keith; Bagby, Stacey; Tentler, John; Tan, Aik-Choon; Wisell, Joshua; Varella-Garcia, Marileila; Robinson, William
2017-01-01
Genomic rearrangements resulting in activating kinase fusions have been increasingly described in a number of cancers including malignant melanoma, but their frequency in specific melanoma subtypes has not been reported. We used break-apart fluorescence in situ hybridization (FISH) to identify genomic rearrangements in tissues from 59 patients with various types of malignant melanoma including acral lentiginous, mucosal, superficial spreading, and nodular. We identified four genomic rearrangements involving the genes BRAF, RET, and ROS1. Of these, three were confirmed by Immunohistochemistry (IHC) or sequencing and one was found to be an ARMC10-BRAF fusion that has not been previously reported in melanoma. These fusions occurred in different subtypes of melanoma but all in tumors lacking known driver mutations. Our data suggest gene fusions are more common than previously thought and should be further explored particularly in melanomas lacking known driver mutations. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Feng, Peng; Wang, Jing; Wei, Biao; Mi, Deling
2013-01-01
A hybrid multiscale and multilevel image fusion algorithm for green fluorescent protein (GFP) image and phase contrast image of Arabidopsis cell is proposed in this paper. Combining intensity-hue-saturation (IHS) transform and sharp frequency localization Contourlet transform (SFL-CT), this algorithm uses different fusion strategies for different detailed subbands, which include neighborhood consistency measurement (NCM) that can adaptively find balance between color background and gray structure. Also two kinds of neighborhood classes based on empirical model are taken into consideration. Visual information fidelity (VIF) as an objective criterion is introduced to evaluate the fusion image. The experimental results of 117 groups of Arabidopsis cell image from John Innes Center show that the new algorithm cannot only make the details of original images well preserved but also improve the visibility of the fusion image, which shows the superiority of the novel method to traditional ones. PMID:23476716
Kinase Gene Fusions in Defined Subsets of Melanoma
Turner, Jacqueline; Couts, Kasey; Sheren, Jamie; Saichaemchan, Siriwimon; Ariyawutyakorn, Witthawat; Avolio, Izabela; Cabral, Ethan; Glogowska, Magdelena; Amato, Carol; Robinson, Steven; Hintzsche, Jennifer; Applegate, Allison; Seelenfreund, Eric; Gonzalez, Rita; Wells, Keith; Bagby, Stacey; Tentler, John; Tan, Aik-Choon; Wisell, Joshua; Varella-Garcia, Marileila; Robinson, William
2017-01-01
Summary Genomic rearrangements resulting in activating kinase fusions have been increasingly described in a number of cancers including malignant melanoma, but their frequency in specific melanoma subtypes has not been reported. We used break-apart fluorescence in-situ hybridization (FISH) to identify genomic rearrangements in tissues from 59 patients with various types of malignant melanoma including acral lentiginous, mucosal, superficial spreading, and nodular. We identified four genomic rearrangements involving the genes BRAF, RET, and ROS1. Of these, three were confirmed by IHC or sequencing and one was found to be an ARMC10-BRAF fusion that has not been previously reported in melanoma. These fusions occurred in different subtypes of melanoma but all in tumors lacking known driver mutations. Our data suggest gene fusions are more common than previously thought-and should be further explored particularly in melanomas lacking known driver mutations. PMID:27864876
Overview of the present progress and activities on the CFETR
NASA Astrophysics Data System (ADS)
Wan, Yuanxi; Li, Jiangang; Liu, Yong; Wang, Xiaolin; Chan, Vincent; Chen, Changan; Duan, Xuru; Fu, Peng; Gao, Xiang; Feng, Kaiming; Liu, Songlin; Song, Yuntao; Weng, Peide; Wan, Baonian; Wan, Farong; Wang, Heyi; Wu, Songtao; Ye, Minyou; Yang, Qingwei; Zheng, Guoyao; Zhuang, Ge; Li, Qiang; CFETR Team
2017-10-01
The China Fusion Engineering Test Reactor (CFETR) is the next device in the roadmap for the realization of fusion energy in China, which aims to bridge the gaps between the fusion experimental reactor ITER and the demonstration reactor (DEMO). CFETR will be operated in two phases. Steady-state operation and self-sufficiency will be the two key issues for Phase I with a modest fusion power of up to 200 MW. Phase II aims for DEMO validation with a fusion power over 1 GW. Advanced H-mode physics, high magnetic fields up to 7 T, high frequency electron cyclotron resonance heating and lower hybrid current drive together with off-axis negative-ion neutral beam injection will be developed for achieving steady-state advanced operation. The recent detailed design, research and development (R&D) activities including integrated modeling of operation scenarios, high field magnet, material, tritium plant, remote handling and future plans are introduced in this paper.
The national ignition facility and atomic data
NASA Astrophysics Data System (ADS)
Crandall, David H.
1998-07-01
The National Ignition Facility (NIF) is under construction, capping over 25 years of development of the inertial confinement fusion concept by providing the facility to obtain fusion ignition in the laboratory for the first time. The NIF is a 192 beam glass laser to provide energy controlled in space and time so that a millimeter-scale capsule containing deuterium and tritium can be compressed to fusion conditions. Light transport, conversion of light in frequency, interaction of light with matter in solid and plasma forms, and diagnostics of extreme material conditions on small scale all use atomic data in preparing for use of the NIF. The NIF will provide opportunity to make measurements of atomic data in extreme physical environments related to fusion energy, nuclear weapon detonation, and astrophysics. The first laser beams of NIF should be operational in 2001 and the full facility completed at the end of 2003. NIF is to provide 1.8 megajoule of blue light on fusion targets and is intended to achieve fusion ignition by about the end of 2007. Today's inertial fusion development activities use atomic data to design and predict fusion capsule performance and in non-fusion applications to analyze radiation transport and radiation effects on matter. Conditions investigated involve radiation temperature of hundreds of eV, pressures up to gigabars and time scales of femptoseconds.
Richard, Christian M; Wright, Richard D; Ee, Cheryl; Prime, Steven L; Shimizu, Yujiro; Vavrik, John
2002-01-01
The effect of a concurrent auditory task on visual search was investigated using an image-flicker technique. Participants were undergraduate university students with normal or corrected-to-normal vision who searched for changes in images of driving scenes that involved either driving-related (e.g., traffic light) or driving-unrelated (e.g., mailbox) scene elements. The results indicated that response times were significantly slower if the search was accompanied by a concurrent auditory task. In addition, slower overall responses to scenes involving driving-unrelated changes suggest that the underlying process affected by the concurrent auditory task is strategic in nature. These results were interpreted in terms of their implications for using a cellular telephone while driving. Actual or potential applications of this research include the development of safer in-vehicle communication devices.
Convection in Cool Stars, as Seen Through Kepler's Eyes
NASA Astrophysics Data System (ADS)
Bastien, Fabienne A.
2015-01-01
Stellar surface processes represent a fundamental limit to the detection of extrasolar planets with the currently most heavily-used techniques. As such, considerable effort has gone into trying to mitigate the impact of these processes on planet detection, with most studies focusing on magnetic spots. Meanwhile, high-precision photometric planet surveys like CoRoT and Kepler have unveiled a wide variety of stellar variability at previously inaccessible levels. We demonstrate that these newly revealed variations are not solely magnetically driven but also trace surface convection through light curve ``flicker.'' We show that ``flicker'' not only yields a simple measurement of surface gravity with a precision of ˜0.1 dex, but it may also improve our knowledge of planet properties, enhance radial velocity planet detection and discovery, and provide new insights into stellar evolution.
Reproducibility of the retinal vascular response to flicker light in Asians.
Nguyen, Thanh T; Kreis, Andreas J; Kawasaki, Ryo; Wang, Jie Jin; Seifert, Bernd-U; Vilser, Walthard; Nagel, Edgar; Wong, Tien Y
2009-12-01
Dilation of retinal vessels in response to diffuse luminance flicker may reflect endothelial function. Although this has previously been shown to be reproducible in whites, there have been no similar data in Asians. We assess the reproducibility of repeated measurements of this response in Asians. Healthy Asians (n = 33) with normal vision and no history of glaucoma, age-related macular degeneration, cataract, or retinal arterial/venous occlusion participated in this study. Repeated measures from the same subjects were taken 30-60 min apart using the Dynamic Vessel Analyser (DVA, IMEDOS, Jena, Germany). Modification was made to the shape of the light source for Asian participants. Correlations of the first and second measures were assessed using Pearson correlation (R(2)), and agreement between the two measures was shown using Bland-Altman plots. After modification to the shape of the light source, almost perfect correlation was found between the 1st and 2nd measurements of baseline arteriolar (R(2) = 0.95) and venular diameters (R(2) = 0.98) of arteriolar maximum dilation (R(2) = 0.85). Substantially high correlation between the 1st and 2nd measurements of venular maximum dilation was found (R(2) = 0.80). Measurements of the dilation response of retinal vessels to diffuse luminance flicker an Asian sample using the DVA show high reproducibility for repeated measures over a short period of time. Such measurements may allow non-invasive quantification of endothelial function to study its association with systemic and ocular diseases.
Modulating the Neutron Flux from a Mirror Neutron Source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ryutov, D D
2011-09-01
A 14-MeV neutron source based on a Gas-Dynamic Trap will provide a high flux of 14 MeV neutrons for fusion materials and sub-component testing. In addition to its main goal, the source has potential applications in condensed matter physics and biophysics. In this report, the author considers adding one more capability to the GDT-based neutron source, the modulation of the neutron flux with a desired frequency. The modulation may be an enabling tool for the assessment of the role of non-steady-state effects in fusion devices as well as for high-precision, low-signal basic science experiments favoring the use of the synchronousmore » detection technique. A conclusion is drawn that modulation frequency of up to 1 kHz and modulation amplitude of a few percent is achievable. Limitations on the amplitude of modulations at higher frequencies are discussed.« less
Yang, Yong; Tong, Song; Huang, Shuying; Lin, Pan
2014-01-01
This paper presents a novel framework for the fusion of multi-focus images explicitly designed for visual sensor network (VSN) environments. Multi-scale based fusion methods can often obtain fused images with good visual effect. However, because of the defects of the fusion rules, it is almost impossible to completely avoid the loss of useful information in the thus obtained fused images. The proposed fusion scheme can be divided into two processes: initial fusion and final fusion. The initial fusion is based on a dual-tree complex wavelet transform (DTCWT). The Sum-Modified-Laplacian (SML)-based visual contrast and SML are employed to fuse the low- and high-frequency coefficients, respectively, and an initial composited image is obtained. In the final fusion process, the image block residuals technique and consistency verification are used to detect the focusing areas and then a decision map is obtained. The map is used to guide how to achieve the final fused image. The performance of the proposed method was extensively tested on a number of multi-focus images, including no-referenced images, referenced images, and images with different noise levels. The experimental results clearly indicate that the proposed method outperformed various state-of-the-art fusion methods, in terms of both subjective and objective evaluations, and is more suitable for VSNs. PMID:25587878
Yang, Yong; Tong, Song; Huang, Shuying; Lin, Pan
2014-11-26
This paper presents a novel framework for the fusion of multi-focus images explicitly designed for visual sensor network (VSN) environments. Multi-scale based fusion methods can often obtain fused images with good visual effect. However, because of the defects of the fusion rules, it is almost impossible to completely avoid the loss of useful information in the thus obtained fused images. The proposed fusion scheme can be divided into two processes: initial fusion and final fusion. The initial fusion is based on a dual-tree complex wavelet transform (DTCWT). The Sum-Modified-Laplacian (SML)-based visual contrast and SML are employed to fuse the low- and high-frequency coefficients, respectively, and an initial composited image is obtained. In the final fusion process, the image block residuals technique and consistency verification are used to detect the focusing areas and then a decision map is obtained. The map is used to guide how to achieve the final fused image. The performance of the proposed method was extensively tested on a number of multi-focus images, including no-referenced images, referenced images, and images with different noise levels. The experimental results clearly indicate that the proposed method outperformed various state-of-the-art fusion methods, in terms of both subjective and objective evaluations, and is more suitable for VSNs.
CNVs leading to fusion transcripts in individuals with autism spectrum disorder
Holt, Richard; Sykes, Nuala H; Conceição, Inês C; Cazier, Jean-Baptiste; Anney, Richard JL; Oliveira, Guiomar; Gallagher, Louise; Vicente, Astrid; Monaco, Anthony P; Pagnamenta, Alistair T
2012-01-01
There is strong evidence that rare copy number variants (CNVs) have a role in susceptibility to autism spectrum disorders (ASDs). Much research has focused on how CNVs mediate a phenotypic effect by altering gene expression levels. We investigated an alternative mechanism whereby CNVs combine the 5′ and 3′ ends of two genes, creating a ‘fusion gene'. Any resulting mRNA with an open reading frame could potentially alter the phenotype via a gain-of-function mechanism. We examined 2382 and 3096 rare CNVs from 996 individuals with ASD and 1287 controls, respectively, for potential to generate fusion transcripts. There was no increased burden in individuals with ASD; 122/996 cases harbored at least one rare CNV of this type, compared with 179/1287 controls (P=0.89). There was also no difference in the overall frequency distribution between cases and controls. We examined specific examples of such CNVs nominated by case–control analysis and a candidate approach. Accordingly, a duplication involving REEP1-POLR1A (found in 3/996 cases and 0/1287 controls) and a single occurrence CNV involving KIAA0319-TDP2 were tested. However, no fusion transcripts were detected by RT-PCR. Analysis of additional samples based on cell line availability resulted in validation of a MAPKAPK5-ACAD10 fusion transcript in two probands. However, this variant was present in controls at a similar rate and is unlikely to influence ASD susceptibility. In summary, although we find no evidence that fusion-gene generating CNVs lead to ASD susceptibility, discovery of a MAPKAPK5-ACAD10 transcript with an estimated frequency of ∼1/200 suggests that gain-of-function mechanisms should be considered in future CNVs studies. PMID:22549408
The transition zone above a lumbosacral fusion.
Hambly, M F; Wiltse, L L; Raghavan, N; Schneiderman, G; Koenig, C
1998-08-15
The clinical and radiographic effect of a lumbar or lumbosacral fusion was studied in 42 patients who had undergone a posterolateral fusion with an average follow-up of 22.6 years. To examine the long-term effects of posterolateral lumbar or lumbosacral fusion on the cephalad two motion segments (transition zone). It is commonly held that accelerated degeneration occurs in the motion segments adjacent to a fusion. Most studies are of short-term, anecdotal, uncontrolled reports that pay particular attention only to the first motion segment immediately cephalad to the fusion. Forty-two patients who had previously undergone a posterolateral lumbar or lumbosacral fusion underwent radiographic and clinical evaluation. Rate of fusion, range of motion, osteophytes, degenerative spondylolisthesis, retrolisthesis, facet arthrosis, disc ossification, dynamic instability, and disc space height were all studied and statistically compared with an age- and gender-matched control group. The patient's self-reported clinical outcome was also recorded. Degenerative changes occurred at the second level above the fused levels with a frequency equal to those occurring in the first level. There was no statistical difference between the study group and the cohort group in the presence of radiographic changes within the transition zone. In those patients undergoing fusion for degenerative processes, 75% reported a good to excellent outcome, whereas 84% of those undergoing fusion for spondylolysis or spondylolisthesis reported a good to excellent outcome. Radiographic changes occur within the transition zone cephalad to a lumbar or lumbosacral fusion. However, these changes are also seen in control subjects who have had no surgery.
Coupled gating of skeletal muscle ryanodine receptors is modulated by Ca2+, Mg2+, and ATP
Porta, Maura; Diaz-Sylvester, Paula L.; Neumann, Jake T.; Escobar, Ariel L.; Fleischer, Sidney
2012-01-01
Coupled gating (synchronous openings and closures) of groups of skeletal muscle ryanodine receptors (RyR1), which mimics RyR1-mediated Ca2+ release underlying Ca2+ sparks, was first described by Marx et al. (Marx SO, Ondrias K, Marks AR. Science 281: 818–821, 1998). The nature of the RyR1-RyR1 interactions for coupled gating still needs to be characterized. Consequently, we defined planar lipid bilayer conditions where ∼25% of multichannel reconstitutions contain mixtures of coupled and independently gating RyR1. In ∼10% of the cases, all RyRs (2–10 channels; most frequently 3–4) gated in coupled fashion, allowing for quantification. Our results indicated that coupling required cytosolic solutions containing ATP/Mg2+ and high (50 mM) luminal Ca2+ (Calum) or Sr2+ solutions. Bursts of coupled activity (events) started and ended abruptly, with all channels activating/deactivating within ∼300 μs. Coupled RyR1 were heterogeneous, where highly active RyR1 (“drivers”) seemed open during the entire coupled event (Po = 1), while other RyR1s (“followers”) displayed abundant flickering and smaller amplitude. Drivers mean open time increased with cytosolic Ca2+ (Cacyt) or caffeine, whereas followers flicker frequency was Cacyt independent and more sensitive to inhibition by cytosolic Mg2+. Coupled events were insensitive to varying lumen-to-cytosol Ca2+ fluxes from ∼1 to 8 pA, which does not corroborate coupling of neighboring RyR1 by local Ca2+-induced Ca2+ release. However, coupling requires specific Calum sites, as it was lost when Calum was replaced by luminal Ba2+ or Mg2+. In summary, coupled events reveal complex interactions among heterogeneous RyR1, differentially modulated by cytosolic ATP/Mg2+, Cacyt, and Calum, which under cell-like ionic conditions may parallel synchronous RyR1 gating during Ca2+ sparks. PMID:22785120
Local Versus Global Effects of Isoflurane Anesthesia on Visual Processing in the Fly Brain
2016-01-01
Abstract What characteristics of neural activity distinguish the awake and anesthetized brain? Drugs such as isoflurane abolish behavioral responsiveness in all animals, implying evolutionarily conserved mechanisms. However, it is unclear whether this conservation is reflected at the level of neural activity. Studies in humans have shown that anesthesia is characterized by spatially distinct spectral and coherence signatures that have also been implicated in the global impairment of cortical communication. We questioned whether anesthesia has similar effects on global and local neural processing in one of the smallest brains, that of the fruit fly (Drosophila melanogaster). Using a recently developed multielectrode technique, we recorded local field potentials from different areas of the fly brain simultaneously, while manipulating the concentration of isoflurane. Flickering visual stimuli (‘frequency tags’) allowed us to track evoked responses in the frequency domain and measure the effects of isoflurane throughout the brain. We found that isoflurane reduced power and coherence at the tagging frequency (13 or 17 Hz) in central brain regions. Unexpectedly, isoflurane increased power and coherence at twice the tag frequency (26 or 34 Hz) in the optic lobes of the fly, but only for specific stimulus configurations. By modeling the periodic responses, we show that the increase in power in peripheral areas can be attributed to local neuroanatomy. We further show that the effects on coherence can be explained by impacted signal-to-noise ratios. Together, our results show that general anesthesia has distinct local and global effects on neuronal processing in the fruit fly brain. PMID:27517084
Local Versus Global Effects of Isoflurane Anesthesia on Visual Processing in the Fly Brain.
Cohen, Dror; Zalucki, Oressia H; van Swinderen, Bruno; Tsuchiya, Naotsugu
2016-01-01
What characteristics of neural activity distinguish the awake and anesthetized brain? Drugs such as isoflurane abolish behavioral responsiveness in all animals, implying evolutionarily conserved mechanisms. However, it is unclear whether this conservation is reflected at the level of neural activity. Studies in humans have shown that anesthesia is characterized by spatially distinct spectral and coherence signatures that have also been implicated in the global impairment of cortical communication. We questioned whether anesthesia has similar effects on global and local neural processing in one of the smallest brains, that of the fruit fly (Drosophila melanogaster). Using a recently developed multielectrode technique, we recorded local field potentials from different areas of the fly brain simultaneously, while manipulating the concentration of isoflurane. Flickering visual stimuli ('frequency tags') allowed us to track evoked responses in the frequency domain and measure the effects of isoflurane throughout the brain. We found that isoflurane reduced power and coherence at the tagging frequency (13 or 17 Hz) in central brain regions. Unexpectedly, isoflurane increased power and coherence at twice the tag frequency (26 or 34 Hz) in the optic lobes of the fly, but only for specific stimulus configurations. By modeling the periodic responses, we show that the increase in power in peripheral areas can be attributed to local neuroanatomy. We further show that the effects on coherence can be explained by impacted signal-to-noise ratios. Together, our results show that general anesthesia has distinct local and global effects on neuronal processing in the fruit fly brain.
Low-frequency noise measurements: applications, methodologies and instrumentation
NASA Astrophysics Data System (ADS)
Ciofi, Carmine; Neri, Bruno
2003-05-01
Low frequency noise measurements (f<10Hz) are a powerful tool for the investigation of the quality and reliability of electron devices and material. In most cases, however, the application of this technique is made quite difficult both because of the effect of external interferences (temperature fluctuations, EMI, mechanical vibrations, etc.) and because of the high level of flicker noise of the commercial instrumentation. In this paper the most remarkable results we obtained by using low frequency noise measurements for the characterization of the reliability of VLSI metallic interconnections and thin oxides are resumed. Moreover, we discuss the effects of the several sources of noise and interferences which contribute to reduce the sensitivity of the measurement chain. In particular, we demonstrate that by means of a proper design, dedicated instrumentation can be built which allows for a considerable reduction of the overall background noise. Examples will be given with reference to voltage and transresistance amplifiers (both AC and DC coupled), to programmable biasing systems (both current and voltage sources), to thermal stabilization systems and to data acquisition systems. Finally, we will discuss methods which may allow, in proper conditions, to accurately measure noise levels well below the background noise of the input preamplifiers coupled to the device under test. As the systems we discuss are characterized by moderate complexity and employ components readily available on the market, we trust that this paper may also serve as a simple guideline to anyone interested in exploiting the possibility of using very low frequency noise measurements by building his own instrumentation.
Perception and Neural Coding of Harmonic Fusion in Ferrets
2004-01-01
distinct percepts that come under the rubric of pitch, be- cause periodicity pitch underlies speakers’ voices and speech prosody, as well as musical ...spectral fusion is unclear for sounds having predominantly low-frequency spectra such as speech, music , and many animal vocalizations. In summary...84, 560–565. von Helmholtz, H. (1863). Die Lehre von den Tonempfindungen als physiologische Grundlage fr die Theorie der Musik . (Vieweg und Sohn
Wang, Pengfei; Lu, Min; Gao, Fei; Guo, Haitao; Xu, Yantao; Hou, Chaoqi; Zhou, Zhiwei; Peng, Bo
2015-01-01
Fusion power offers the prospect of an almost inexhaustible source of energy for future generations. It was reported that fusion fuel gains exceeding unity on the National Ignition Facility (NIF) were achieved, but so far great deal of scientific and engineering challenges have to be overcome for realizing fusion power generation. There is a bottleneck for color-separation gratings in NIF and other similar inertial confinement fusion (ICF) lasers. Here we show a series of high performance phosphate-based glasses that can transmit the third harmonic frequency (3ω) laser light with high efficiency meanwhile filter the fundamental (1ω) and the second harmonic frequency (2ω) laser lights through direct absorption, and especially they exhibit excellent damage threshold induced by nanosecond pulse laser compared with that of the fused silica used in NIF. Yellowish-orange fluorescence emits during the laser-material interaction process, and it can be tailored through regulating the glass structure. Study on its structural origin suggests that the fluorescence emission is a key factor that conduces to the high laser-induced damage resistance of these glasses. The results also indicated the feasibility of utilizing these high performance glasses in novel color separation optics, allowing novel design for the final optics assembly in ICF lasers. PMID:25716328
Wang, Pengfei; Lu, Min; Gao, Fei; Guo, Haitao; Xu, Yantao; Hou, Chaoqi; Zhou, Zhiwei; Peng, Bo
2015-02-26
Fusion power offers the prospect of an almost inexhaustible source of energy for future generations. It was reported that fusion fuel gains exceeding unity on the National Ignition Facility (NIF) were achieved, but so far great deal of scientific and engineering challenges have to be overcome for realizing fusion power generation. There is a bottleneck for color-separation gratings in NIF and other similar inertial confinement fusion (ICF) lasers. Here we show a series of high performance phosphate-based glasses that can transmit the third harmonic frequency (3ω) laser light with high efficiency meanwhile filter the fundamental (1ω) and the second harmonic frequency (2ω) laser lights through direct absorption, and especially they exhibit excellent damage threshold induced by nanosecond pulse laser compared with that of the fused silica used in NIF. Yellowish-orange fluorescence emits during the laser-material interaction process, and it can be tailored through regulating the glass structure. Study on its structural origin suggests that the fluorescence emission is a key factor that conduces to the high laser-induced damage resistance of these glasses. The results also indicated the feasibility of utilizing these high performance glasses in novel color separation optics, allowing novel design for the final optics assembly in ICF lasers.
Simultaneous EEG/fMRI analysis of the resonance phenomena in steady-state visual evoked responses.
Bayram, Ali; Bayraktaroglu, Zubeyir; Karahan, Esin; Erdogan, Basri; Bilgic, Basar; Ozker, Muge; Kasikci, Itir; Duru, Adil D; Ademoglu, Ahmet; Oztürk, Cengizhan; Arikan, Kemal; Tarhan, Nevzat; Demiralp, Tamer
2011-04-01
The stability of the steady-state visual evoked potentials (SSVEPs) across trials and subjects makes them a suitable tool for the investigation of the visual system. The reproducible pattern of the frequency characteristics of SSVEPs shows a global amplitude maximum around 10 Hz and additional local maxima around 20 and 40 Hz, which have been argued to represent resonant behavior of damped neuronal oscillators. Simultaneous electroencephalogram/functional magnetic resonance imaging (EEG/fMRI) measurement allows testing of the resonance hypothesis about the frequency-selective increases in SSVEP amplitudes in human subjects, because the total synaptic activity that is represented in the fMRI-Blood Oxygen Level Dependent (fMRI-BOLD) response would not increase but get synchronized at the resonance frequency. For this purpose, 40 healthy volunteers were visually stimulated with flickering light at systematically varying frequencies between 6 and 46 Hz, and the correlations between SSVEP amplitudes and the BOLD responses were computed. The SSVEP frequency characteristics of all subjects showed 3 frequency ranges with an amplitude maximum in each of them, which roughly correspond to alpha, beta and gamma bands of the EEG. The correlation maps between BOLD responses and SSVEP amplitude changes across the different stimulation frequencies within each frequency band showed no significant correlation in the alpha range, while significant correlations were obtained in the primary visual area for the beta and gamma bands. This non-linear relationship between the surface recorded SSVEP amplitudes and the BOLD responses of the visual cortex at stimulation frequencies around the alpha band supports the view that a resonance at the tuning frequency of the thalamo-cortical alpha oscillator in the visual system is responsible for the global amplitude maximum of the SSVEP around 10 Hz. Information gained from the SSVEP/fMRI analyses in the present study might be extrapolated to the EEG/fMRI analysis of the transient event-related potentials (ERPs) in terms of expecting more reliable and consistent correlations between EEG and fMRI responses, when the analyses are carried out on evoked or induced oscillations (spectral perturbations) in separate frequency bands instead of the time-domain ERP peaks.
Recent Trends in Fusion Gyrotron Development at KIT
NASA Astrophysics Data System (ADS)
Gantenbein, G.; Avramidis, K.; Franck, J.; Illy, S.; Ioannidis, Z. C.; Jin, J.; Jelonnek, J.; Kalaria, P.; Pagonakis, I. Gr.; Ruess, S.; Rzesnicki, T.; Thumm, M.; Wu, C.
2017-10-01
ECRH&CD is one of the favorite heating system for magnetically confined nuclear fusion plasmas. KIT is strongly involved in the development of high power gyrotrons for use in ECRH systems for nuclear fusion. KIT is upgrading the sub-components of the existing 2 MW, 170 GHz coaxial-cavity short-pulse gyrotron to support long-pulse operation up to 1 s, all components will be equipped with a specific active cooling system. Two important developments for future high power, highly efficient gyrotrons will be discussed: design of gyrotrons with high operating frequency (˜ 240 GHz) and efficiency enhancement by using advanced collector designs with multi-staged voltage depression.
Compressed Gas Safety for Experimental Fusion Facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee C. Cadwallader
2004-09-01
Experimental fusion facilities present a variety of hazards to the operators and staff. There are unique or specialized hazards, including magnetic fields, cryogens, radio frequency emissions, and vacuum reservoirs. There are also more general industrial hazards, such as a wide variety of electrical power, pressurized air, and cooling water systems in use, there are crane and hoist loads, working at height, and handling compressed gas cylinders. This paper outlines the projectile hazard assoicated with compressed gas cylinders and mthods of treatment to provide for compressed gas safety. This information should be of interest to personnel at both magnetic and inertialmore » fusion experiments.« less
Optical images of visible and invisible percepts in the primary visual cortex of primates
Macknik, Stephen L.; Haglund, Michael M.
1999-01-01
We optically imaged a visual masking illusion in primary visual cortex (area V-1) of rhesus monkeys to ask whether activity in the early visual system more closely reflects the physical stimulus or the generated percept. Visual illusions can be a powerful way to address this question because they have the benefit of dissociating the stimulus from perception. We used an illusion in which a flickering target (a bar oriented in visual space) is rendered invisible by two counter-phase flickering bars, called masks, which flank and abut the target. The target and masks, when shown separately, each generated correlated activity on the surface of the cortex. During the illusory condition, however, optical signals generated in the cortex by the target disappeared although the image of the masks persisted. The optical image thus was correlated with perception but not with the physical stimulus. PMID:10611363
Caird, Jeff K; Edwards, Christopher J; Creaser, Janet I; Horrey, William J
2005-01-01
A modified version of the flicker technique to induce change blindness was used to examine the effects of time constraints on decision-making accuracy at intersections on a total of 62 young (18-25 years), middle-aged (26-64 years), young-old (65-73 years), and old-old (74+ years) drivers. Thirty-six intersection photographs were manipulated so that one object (i.e., pedestrian, vehicle, sign, or traffic control device) in the scene would change when the images were alternated for either 5 or 8 s using the modified flicker method. Young and middle-aged drivers made significantly more correct decisions than did young-old and old-old drivers. Logistic regression analysis of the data indicated that age and/or time were significant predictors of decision performance in 14 of the 36 intersections. Actual or potential applications of this research include driving assessment and crash investigation.
Characterization of zero-bias microwave diode power detectors at cryogenic temperature.
Giordano, Vincent; Fluhr, Christophe; Dubois, Benoît; Rubiola, Enrico
2016-08-01
We present the characterization of commercial tunnel diode low-level microwave power detectors at room and cryogenic temperatures. The sensitivity as well as the output voltage noise of the tunnel diodes is measured as functions of the applied microwave power. We highlight strong variations of the diode characteristics when the applied microwave power is higher than a few microwatts. For a diode operating at 4 K, the differential gain increases from 1000 V/W to about 4500 V/W when the power passes from -30 dBm to -20 dBm. The diode white noise floor is equivalent to a Noise Equivalent Power of 0.8 pW/Hz and 8 pW/Hz at 4 K and 300 K, respectively. Its flicker noise is equivalent to a relative amplitude noise power spectral density Sα(1 Hz) = - 120 dB/Hz at 4 K. Flicker noise is 10 dB higher at room temperature.
Traditional use of the Andean flicker (Colaptes rupicola) as a galactagogue in the Peruvian Andes
Froemming, Steve
2006-01-01
This paper explores the use of the dried meat and feathers of the Andean Flicker (Colaptes rupicola) to increase the milk supply of nursing women and domestic animals in the Andes. The treatment is of preColumbian origin, but continues to be used in some areas, including the village in the southern Peruvian highlands where I do ethnographic research. I explore the factors giving rise to and sustaining the practice, relate it to other galactagogues used in the Andes and to the use of birds in ethnomedical and ethnoveterinary treatments in general, and situate it within the general tendency in the Andes and elsewhere to replicate human relations in the treatment of valuable livestock. The bird's use as a galactagogue appears to be motivated by both metaphorical associations and its perceived efficacy, and conceptually blends human and animal healthcare domains. PMID:16677398
Dumont, Sarah N; Lazar, Alexander J; Bridge, Julia A; Benjamin, Robert S; Trent, Jonathan C
2012-02-01
In pediatric alveolar rhabdomyosarcoma, the PAX3-FOXO1 and PAX7-FOXO1 gene fusions are prognostic indicators, while little is known concerning this disease in older patients. To determine whether PAX3/7-FOXO1 fusion gene status correlates with outcome in adolescent, young adult, and adult rhabdomyosarcoma patients, the histological, immunohistochemical, and clinical characteristics of 105 patients followed at The University of Texas MD Anderson Cancer Center from 1957 to 2001 were evaluated. The samples were assembled into a tissue microarray, and fusion gene status was determined by fluorescence in situ hybridization using PAX3, PAX7, and FOXO1 loci-specific probes. The disease characteristics and specific gene fusion were correlated with patient outcomes using the log-rank test. Fifty-two percent of the samples exhibited a PAX3-FOXO1 fusion, 15% the PAX7-FOXO1 fusion, and 33% were negative for a rearrangement of these loci. The presence of PAX3/7-FOXO1 translocation was significantly associated with a higher frequency of metastatic disease. Although a statistically significant correlation between the PAX3/7-FOXO1 fusion gene status and overall survival was not identified, there was a trend toward better outcomes for patients with fusion-negative RMS. Therefore, identification of a FOXO1 fusion appears to be an interesting tool for predicting outcomes in older rhabdomyosarcoma patients and is worth further investigations in this rare subgroup of RMS population.
Iudice, A; Bonanni, E; Gelli, A; Frittelli, C; Iudice, G; Cignoni, F; Ghicopulos, I; Murri, L
2005-03-01
Simulated driving ability was assessed following administration of alcohol, at an estimated blood level of 0.05%, and combined prolonged wakefulness, while participants were undertaking divided attention tasks over a hands-free mobile phone. Divided attention tasks were structured to provide a sustained cognitive workload to the subjects. Twenty three young healthy individuals drove 10 km simulated driving under four conditions in a counterbalanced, within-subject design: alcohol, alcohol and 19 h wakefulness, alcohol and 24 h wakefulness, and while sober. Study measures were: simulated driving, self-reported sleepiness, critical flicker fusion threshold (CFFT), Stroop word-colour interference test (Stroop) and simple visual reaction times (SVRT). As expected, subjective sleepiness was highly correlated with both sleep restriction and alcohol consumption. The combination of alcohol and 24 h sustained wakefulness produced the highest driving impairment, significantly beyond the alcohol effect itself. Concurrent alcohol and 19 h wakefulness significantly affected only driving time-to-collision. No significant changes of study measures occurred following alcohol intake in unrestricted sleep conditions. CFFT, SVRT and Stroop results showed a similar trend in the four study conditions. Thus apparently 'safe' blood alcohol levels in combination with prolonged wakefulness resulted in significant driving impairments. In normal sleep conditions alcohol effects on driving were partially counteracted by the concomitant hands-free phone based psychometric tasks. 2005 John Wiley & Sons, Ltd.
Alken, R G; Belz, G G
1984-01-01
We tested the hypothesis that differences exist in the pharmacodynamic pattern of different cardiac glycosides. We conducted a randomized, placebo-controlled study in normal volunteers and evaluated the effects of weekly increased oral dosing of digoxin (n = 10; from 0.25 to 1.0 mg/day), meproscillarin (n = 10; from 0.5 to 2.0 mg/day), and placebo (n = 5). To determine the glycoside effects, corrected electromechanical systole (QS2c) was used to measure inotropy and the PQ interval to test dromotropy. Red-green discrimination and critical flicker fusion (CFF) assessed visual functions. Subjective complaints were collected using rating lists. Both glycosides dose dependently shortened QS2c and prolonged PQ interval. PQ prolongations over +20 ms occurred in seven of 10 digoxin subjects, in two of 10 meproscillarin, and in one of five placebo. Equi-inotropic response, identified at 12 ms mean QS2c shortening, revealed the relative potency of digoxin to be 2.4 times higher than meproscillarin; this ratio increased to sevenfold for equi-effective negative dromotropic effects at 12 ms mean PQ prolongation. Each drug was associated with a dominant subjective complaint: digoxin with anergy and meproscillarin with diarrhea. Red-green discrimination was better under meproscillarin and CFF was depressed by digoxin. The results indicate that pharmacodynamic differences exist between cardiac glycosides. A differential use of various glycosides should be considered and tested clinically.
Acute and subchronic effects of Org 2305 and diazepam on psychomotor performance in man.
Mattila, M J; Koski, J; Strömberg, C
1987-02-01
Three doses (15, 30 and 60 mg) of Org 2305 (O 15, O 30 and O 60 respectively), a novel anxiolytic drug chemically related to mianserin, were compared with placebo and 15 mg diazepam (DZ) on human psychomotor performance in a double-blind, cross-over study with 15 healthy volunteers. Objective measurements (choice reaction, tracking, flicker fusion, Maddox wing, digit symbol substitution, memory recall) and subjective assessments (visual analogue scales) were done at baseline and 2 and 13 h after the first dose. This testing procedure was repeated on day 7 when administering the seventh consecutive daily night-time dose. After the first dose O 15 did not differ from placebo and O 30 rarely differed from placebo. O 60 impaired various objective functions similarly to, or less than DZ. Subjectively, DZ and O 60 were felt as sedative. During subchronic treatment, DZ caused some impairment of baseline due to accumulation of bioassayable benzodiazepines, but significant responses to the last DZ dose were less than those to the first dose. DZ but not O 60 was reported to have caused lethargy and clumsiness during subchronic treatment. In the doses used Org 2305 impaired psychomotor performance less than diazepam did. A dose of 60 mg Org 2305 may offer some advantage over 15 mg diazepam, provided that their anxiolytic effects are about similar.
Petrova, Daniela; Henning, G. Bruce; Stockman, Andrew
2013-01-01
Flickering long-wavelength light appears more yellow than steady light of the same average intensity. The hue change is consistent with distortion of the visual signal at some nonlinear site (or sites) that produces temporal components not present in the original stimulus (known as distortion products). We extracted the temporal attenuation characteristics of the early (prenonlinearity) and late (post-nonlinearity) filter stages in the L- and M-cone chromatic pathway by varying the input stimulus to manipulate the distortion products and the measuring of the observers' sensitivity to them. The early, linear, filter stage acts like a band-pass filter peaking at 10–15 Hz with substantial sensitivity losses at both lower and higher frequencies. Its characteristics are consistent with nonlinearity being early in the visual pathway but following surround inhibition. The late stage, in contrast, acts like a low-pass filter with a cutoff frequency around 3 Hz. The response of the early stage speeds up with radiance, but the late stage does not. A plausible site for the nonlinearity, which modelling suggests may be smoothly compressive but with a hard limit at high input levels, is after surround inhibition from the horizontal cells. PMID:23457358
Liao, Wugang; Wei, Wei; Tong, Yu; Chim, Wai Kin; Zhu, Chunxiang
2018-02-28
Layered rhenium disulfide (ReS 2 ) field effect transistors (FETs), with thickness ranging from few to dozens of layers, are demonstrated on 20 nm thick HfO 2 /Si substrates. A small threshold voltage of -0.25 V, high on/off current ratio of up to ∼10 7 , small subthreshold swing of 116 mV/dec, and electron carrier mobility of 6.02 cm 2 /V·s are obtained for the two-layer ReS 2 FETs. Low-frequency noise characteristics in ReS 2 FETs are analyzed for the first time, and it is found that the carrier number fluctuation mechanism well describes the flicker (1/f) noise of ReS 2 FETs with different thicknesses. pH sensing using a two-layer ReS 2 FET with HfO 2 as a sensing oxide is then demonstrated with a voltage sensitivity of 54.8 mV/pH and a current sensitivity of 126. The noise characteristics of the ReS 2 FET-based pH sensors are also examined, and a corresponding detection limit of 0.0132 pH is obtained. Our studies suggest the high potential of ReS 2 for future low-power nanoelectronics and biosensor applications.
Laser Frequency Noise in Coherent Optical Systems: Spectral Regimes and Impairments.
Kakkar, Aditya; Rodrigo Navarro, Jaime; Schatz, Richard; Pang, Xiaodan; Ozolins, Oskars; Udalcovs, Aleksejs; Louchet, Hadrien; Popov, Sergei; Jacobsen, Gunnar
2017-04-12
Coherent communication networks are based on the ability to use multiple dimensions of the lightwave together with electrical domain compensation of transmission impairments. Electrical-domain dispersion compensation (EDC) provides many advantages such as network flexibility and enhanced fiber nonlinearity tolerance, but makes the system more susceptible to laser frequency noise (FN), e.g. to the local oscillator FN in systems with post-reception EDC. Although this problem has been extensively studied, statistically, for links assuming lasers with white-FN, many questions remain unanswered. Particularly, the influence of a realistic non-white FN-spectrum due to e.g., the presence of 1/f-flicker and carrier induced noise remains elusive and a statistical analysis becomes insufficient. Here we provide an experimentally validated theory for coherent optical links with lasers having general non-white FN-spectrum and EDC. The fundamental reason of the increased susceptibility is shown to be FN-induced symbol displacement that causes timing jitter and/or inter/intra symbol interference. We establish that different regimes of the laser FN-spectrum cause a different set of impairments. The influence of the impairments due to some regimes can be reduced by optimizing the corresponding mitigation algorithms, while other regimes cause irretrievable impairments. Theoretical boundaries of these regimes and corresponding criteria applicable to system/laser design are provided.
Subjective and objective evaluation of visual fatigue on viewing 3D display continuously
NASA Astrophysics Data System (ADS)
Wang, Danli; Xie, Yaohua; Yang, Xinpan; Lu, Yang; Guo, Anxiang
2015-03-01
In recent years, three-dimensional (3D) displays become more and more popular in many fields. Although they can provide better viewing experience, they cause extra problems, e.g., visual fatigue. Subjective or objective methods are usually used in discrete viewing processes to evaluate visual fatigue. However, little research combines subjective indicators and objective ones in an entirely continuous viewing process. In this paper, we propose a method to evaluate real-time visual fatigue both subjectively and objectively. Subjects watch stereo contents on a polarized 3D display continuously. Visual Reaction Time (VRT), Critical Flicker Frequency (CFF), Punctum Maximum Accommodation (PMA) and subjective scores of visual fatigue are collected before and after viewing. During the viewing process, the subjects rate the visual fatigue whenever it changes, without breaking the viewing process. At the same time, the blink frequency (BF) and percentage of eye closure (PERCLOS) of each subject is recorded for comparison to a previous research. The results show that the subjective visual fatigue and PERCLOS increase with time and they are greater in a continuous process than a discrete one. The BF increased with time during the continuous viewing process. Besides, the visual fatigue also induced significant changes of VRT, CFF and PMA.
On current transients in MoS2 Field Effect Transistors.
Macucci, Massimo; Tambellini, Gerry; Ovchinnikov, Dmitry; Kis, Andras; Iannaccone, Giuseppe; Fiori, Gianluca
2017-09-14
We present an experimental investigation of slow transients in the gate and drain currents of MoS 2 -based transistors. We focus on the measurement of both the gate and drain currents and, from the comparative analysis of the current transients, we conclude that there are at least two independent trapping mechanisms: trapping of charges in the silicon oxide substrate, occurring with time constants of the order of tens of seconds and involving charge motion orthogonal to the MoS 2 sheet, and trapping at the channel surface, which occurs with much longer time constants, in particular when the device is in a vacuum. We observe that the presence of such slow phenomena makes it very difficult to perform reliable low-frequency noise measurements, requiring a stable and repeatable steady-state bias point condition, and may explain the sometimes contradictory results that can be found in the literature about the dependence of the flicker noise power spectral density on gate bias.
NASA Astrophysics Data System (ADS)
Wang, Mi; Martínez, Francisco J.; Márquez, Andrés.; Ye, Yabin; Zong, Liangjia; Pascual, Inmaculada; Beléndez, Augusto
2017-08-01
Liquid-crystal on Silicon (LCoS) microdisplays are one of the competing technologies to implement wavelength selective switches (WSS) for optical telecommunications. Last generation LCoS, with more than 4 megapixels, have decreased pixel size to values smaller than 4 microns, what increases interpixel cross-talk effects such as fringing-field. We proceed with an experimental evaluation of a 3.74 micron pixel size parallel-aligned LCoS (PA-LCoS) device. At 1550 nm, for the first time we use time-average Stokes polarimetry to measure the retardance and its flicker magnitude as a function of voltage. We also verify the effect of the antireflection coating when we try to characterize the PA-LCoS out of the designed interval for the AR coating. Some preliminary results for the performance for binary gratings are also given, where the decrease of modulation range with the increase in spatial frequency is shown, together with some residual polarization effects.
VLC-beacon detection with an under-sampled ambient light sensor
NASA Astrophysics Data System (ADS)
Green, Jacob; Pérez-Olivas, Huetzin; Martínez-Díaz, Saúl; García-Márquez, Jorge; Domínguez-González, Carlos; Santiago-Montero, Raúl; Guan, Hongyu; Rozenblat, Marc; Topsu, Suat
2017-08-01
LEDs will replace in a near future the current worldwide lighting mainly due to their low production-cost and energy-saving assets. Visible light communications (VLC) will turn gradually the existing lighting network into a communication network. Nowadays VLC transceivers can be found in some commercial centres in Europe; some of them broadcast continuously an identification tag that contains its coordinate position. In such a case, the transceiver acts as a geolocation beacon. Nevertheless, mobile transceivers represent a challenge in the VLC communication chain, as smartphones have not integrated yet a VLC customized detection stage. In order to make current smartphones capable to detect VLC broadcasted signals, their Ambient Light Sensor (ALS) is adapted as a VLC detector. For this to be achieved, lighting transceivers need to adapt their modulation scheme. For instance, frequencies representing start bit, 1, and 0 logic values can be set to avoid flicker from illumination and to permit detecting the under-sampled signal. Decoding the signal requires a multiple steps real-time signal processing as shown here.
Warot, D; Lacomblez, L; Danjou, P; Weiller, E; Payan, C; Puech, A J
1991-01-01
The effect on psychomotor and mnesic performances of acute oral dose (600 mg) of 2 Ginkgo biloba extracts were evaluated in twelve healthy female in a dummy placebo-controlled double blind study. Tests were performed comprising: objective measures of vigilance [critical flicker frequency (CFF), choice reaction time (CRT)], memory tasks (pictures and Sternberg scanning tests) and self-rating evaluation (visual analogue scales). Tests session took place before and 1 hour post-dosing. No statistically significant changes from placebo were observed on CFF, CRT or subjective rating of drug effects. No differences between treatment were evidenced on Sternberg scanning test and pictures recognition. Comparing to baseline, free recall score, while decreasing under placebo and Ginkgo, remained the same under Tanakan. As the differences between treatment are localized on one test, it appears important to examine the reproductility in healthy subjects. In order to verify the clinical relevance of these results, they need to be replicated in older healthy volunteers with age-associated memory impairment.
Apparatus and method for extracting power from energetic ions produced in nuclear fusion
Fisch, N.J.; Rax, J.M.
1994-12-20
An apparatus and method of extracting power from energetic ions produced by nuclear fusion in a toroidal plasma to enhance respectively the toroidal plasma current and fusion reactivity. By injecting waves of predetermined frequency and phase traveling substantially in a selected poloidal direction within the plasma, the energetic ions become diffused in energy and space such that the energetic ions lose energy and amplify the waves. The amplified waves are further adapted to travel substantially in a selected toroidal direction to increase preferentially the energy of electrons traveling in one toroidal direction which, in turn, enhances or generates a toroidal plasma current. In an further adaptation, the amplified waves can be made to preferentially increase the energy of fuel ions within the plasma to enhance the fusion reactivity of the fuel ions. The described direct, or in situ, conversion of the energetic ion energy provides an efficient and economical means of delivering power to a fusion reactor. 4 figures.
Apparatus and method for extracting power from energetic ions produced in nuclear fusion
Fisch, Nathaniel J.; Rax, Jean M.
1994-01-01
An apparatus and method of extracting power from energetic ions produced by nuclear fusion in a toroidal plasma to enhance respectively the toroidal plasma current and fusion reactivity. By injecting waves of predetermined frequency and phase traveling substantially in a selected poloidal direction within the plasma, the energetic ions become diffused in energy and space such that the energetic ions lose energy and amplify the waves. The amplified waves are further adapted to travel substantially in a selected toroidal direction to increase preferentially the energy of electrons traveling in one toroidal direction which, in turn, enhances or generates a toroidal plasma current. In an further adaptation, the amplified waves can be made to preferentially increase the energy of fuel ions within the plasma to enhance the fusion reactivity of the fuel ions. The described direct, or in situ, conversion of the energetic ion energy provides an efficient and economical means of delivering power to a fusion reactor.
Kim, Hyun-Tae; Sips, A. C. C.; Romanelli, M.; ...
2018-02-01
This article presents the transport analysis of high density baseline discharges in the 2016 experimental campaign of the Joint European Torus with the ITER-Like Wall (JET-ILW), where a significant increase in the deuterium–deuterium (D–D) fusion neutron rate (~2.8 × 10 16 s -1) was achieved with stable high neutral beam injection (NBI) powers of up to 28 MW and low gas puffing. Increase in T i exceeding T e were produced for the first time in baseline discharges despite the high electron density; this enabled a significant increase in the thermal fusion reaction rate. As a result, the new achievedmore » record in fusion performance was much higher than the previous record in the same heating power baseline discharges, where T i = T e. In addition to the decreases in collisionality and the increases in ion heating fraction in the discharges with high NBI power, T i > T e can also be attributed to positive feedback between the high T i/T e ratio and stabilisation of the turbulent heat flux resulting from the ion temperature gradient driven mode. The high T i/T e ratio was correlated with high rotation frequency. Among the discharges with identical beam heating power, higher rotation frequencies were observed when particle fuelling was provided by low gas puffing and pellet injection. Lastly, this reveals that particle fuelling played a key role for achieving high T i/T e, and the improved fusion performance.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Hyun-Tae; Sips, A. C. C.; Romanelli, M.
This article presents the transport analysis of high density baseline discharges in the 2016 experimental campaign of the Joint European Torus with the ITER-Like Wall (JET-ILW), where a significant increase in the deuterium–deuterium (D–D) fusion neutron rate (~2.8 × 10 16 s -1) was achieved with stable high neutral beam injection (NBI) powers of up to 28 MW and low gas puffing. Increase in T i exceeding T e were produced for the first time in baseline discharges despite the high electron density; this enabled a significant increase in the thermal fusion reaction rate. As a result, the new achievedmore » record in fusion performance was much higher than the previous record in the same heating power baseline discharges, where T i = T e. In addition to the decreases in collisionality and the increases in ion heating fraction in the discharges with high NBI power, T i > T e can also be attributed to positive feedback between the high T i/T e ratio and stabilisation of the turbulent heat flux resulting from the ion temperature gradient driven mode. The high T i/T e ratio was correlated with high rotation frequency. Among the discharges with identical beam heating power, higher rotation frequencies were observed when particle fuelling was provided by low gas puffing and pellet injection. Lastly, this reveals that particle fuelling played a key role for achieving high T i/T e, and the improved fusion performance.« less
NASA Astrophysics Data System (ADS)
Kim, Hyun-Tae; Sips, A. C. C.; Romanelli, M.; Challis, C. D.; Rimini, F.; Garzotti, L.; Lerche, E.; Buchanan, J.; Yuan, X.; Kaye, S.; contributors, JET
2018-03-01
This paper presents the transport analysis of high density baseline discharges in the 2016 experimental campaign of the Joint European Torus with the ITER-Like Wall (JET-ILW), where a significant increase in the deuterium-deuterium (D-D) fusion neutron rate (~2.8 × 1016 s-1) was achieved with stable high neutral beam injection (NBI) powers of up to 28 MW and low gas puffing. Increase in T i exceeding T e were produced for the first time in baseline discharges despite the high electron density; this enabled a significant increase in the thermal fusion reaction rate. As a result, the new achieved record in fusion performance was much higher than the previous record in the same heating power baseline discharges, where T i = T e. In addition to the decreases in collisionality and the increases in ion heating fraction in the discharges with high NBI power, T i > T e can also be attributed to positive feedback between the high T i/T e ratio and stabilisation of the turbulent heat flux resulting from the ion temperature gradient driven mode. The high T i/T e ratio was correlated with high rotation frequency. Among the discharges with identical beam heating power, higher rotation frequencies were observed when particle fuelling was provided by low gas puffing and pellet injection. This reveals that particle fuelling played a key role for achieving high T i/T e, and the improved fusion performance.
Sabatini, Angelo Maria; Genovese, Vincenzo
2014-07-24
A sensor fusion method was developed for vertical channel stabilization by fusing inertial measurements from an Inertial Measurement Unit (IMU) and pressure altitude measurements from a barometric altimeter integrated in the same device (baro-IMU). An Extended Kalman Filter (EKF) estimated the quaternion from the sensor frame to the navigation frame; the sensed specific force was rotated into the navigation frame and compensated for gravity, yielding the vertical linear acceleration; finally, a complementary filter driven by the vertical linear acceleration and the measured pressure altitude produced estimates of height and vertical velocity. A method was also developed to condition the measured pressure altitude using a whitening filter, which helped to remove the short-term correlation due to environment-dependent pressure changes from raw pressure altitude. The sensor fusion method was implemented to work on-line using data from a wireless baro-IMU and tested for the capability of tracking low-frequency small-amplitude vertical human-like motions that can be critical for stand-alone inertial sensor measurements. Validation tests were performed in different experimental conditions, namely no motion, free-fall motion, forced circular motion and squatting. Accurate on-line tracking of height and vertical velocity was achieved, giving confidence to the use of the sensor fusion method for tracking typical vertical human motions: velocity Root Mean Square Error (RMSE) was in the range 0.04-0.24 m/s; height RMSE was in the range 5-68 cm, with statistically significant performance gains when the whitening filter was used by the sensor fusion method to track relatively high-frequency vertical motions.
Silicon Carbide (SiC) MOSFET-based Full-Bridge for Fusion Science Applications
NASA Astrophysics Data System (ADS)
Ziemba, Timothy; Miller, Kenneth; Prager, James; Picard, Julian; Hashim, Akel
2014-10-01
Switching power amplifiers (SPAs) have a wide variety of applications within the fusion science community, including feedback and control systems for dynamic plasma stabilization in tokamaks, inductive and arc plasma sources, Radio Frequency (RF) helicity and flux injection, RF plasma heating and current drive schemes, ion beam generation, and RF pre-ionizer systems. SiC MOSFETs offer many advantages over IGBTs including lower drive energy requirements, lower conduction and switching losses, and higher switching frequency capabilities. When comparing SiC and traditional silicon-based MOSFETs, SiC MOSFETs provide higher current carrying capability allowing for smaller package weights and sizes and lower operating temperature. Eagle Harbor Technologies (EHT) is designing, constructing, and testing a SiC MOSFET-based full-bridge SPA. EHT will leverage the proprietary gate drive technology previously developed with the support of a DOE SBIR, which will enable fast, efficient switching in a small form factor. The primary goal is to develop a SiC MOSFET-based SPA for fusion science applications. Work supported in part by the DOE under Contract Number DE-SC0011907.
NASA Astrophysics Data System (ADS)
Choi, WooJhon; Baumann, Bernhard; Clermont, Allen C.; Feener, Edward P.; Boas, David A.; Fujimoto, James G.
2013-03-01
Measuring retinal hemodynamics in response to flicker stimulus is important for investigating pathophysiology in small animal models of diabetic retinopathy, because a reduction in the hyperemic response is thought to be one of the earliest changes in diabetic retinopathy. In this study, we investigated functional imaging of retinal hemodynamics in response to flicker stimulus in the rat retina using an ultrahigh speed spectral / Fourier domain OCT system at 840nm with an axial scan rate of 244kHz. At 244kHz the nominal axial velocity range that could be measured without phase wrapping was +/-37.7mm/s. Pulsatile total retinal arterial blood flow as a function of time was measured using an en face Doppler approach where a 200μm × 200μm area centered at the central retinal artery was repeatedly raster scanned at a volume acquisition rate of 55Hz. Three-dimensional capillary imaging was performed using speckle decorrelation which has minimal angle dependency compared to other angiography techniques based on OCT phase information. During OCT imaging, a flicker stimulus could be applied to the retina synchronously by inserting a dichroic mirror in the imaging interface. An acute transient increase in total retinal blood flow could be detected. At the capillary level, an increase in the degree of speckle decorrelation in capillary OCT angiography images could also be observed, which indicates an increase in the velocity of blood at the capillary level. This method promises to be useful for the investigation of small animal models of ocular diseases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaplan, C.R.; Shaddix, C.R.; Smyth, K.C.
This paper presents time-dependent numerical simulations of both steady and time-varying CH{sub 4}/air diffusion flames to examine the differences in combustion conditions which lead to the observed enhancement in soot production in the flickering flames. The numerical model solves the two-dimensional, time-dependent, reactive-flow Navier-Stokes equations coupled with submodels for soot formation and radiation transport. Qualitative comparisons between the experimental and computed steady flame show good agreement for the soot burnout height and overall flame shape except near the burner lip. Quantitative comparisons between experimental and computed radial profiles of temperature and soot volume fraction for the steady flame show goodmore » to excellent agreement at mid-flame heights, but some discrepancies near the burner lip and at high flame heights. For the time-varying CH{sub 4}/air flame, the simulations successfully predict that the maximum soot concentration increases by over four times compared to the steady flame with the same mean fuel and air velocities. By numerically tracking fluid parcels in the flowfield, the temperature and stoichiometry history were followed along their convective pathlines. Results for the pathline which passes through the maximum sooting region show that flickering flames exhibit much longer residence times during which the local temperatures and stoichiometries are favorable for soot production. The simulations also suggest that soot inception occurs later in flickering flames, and at slightly higher temperatures and under somewhat leaner conditions compared to the steady flame. The integrated soot model of Syed et al., which was developed from a steady CH{sub 4}/air flame, successfully predicts soot production in the time-varying CH{sub 4}/air flames.« less
Doskocz, Joanna; Drabik, Dominik; Chodaczek, Grzegorz; Przybyło, Magdalena; Langner, Marek
2018-06-01
Bending rigidity coefficient describes propensity of a lipid bilayer to deform. In order to measure the parameter experimentally using flickering noise spectroscopy, the microscopic imaging is required, which necessitates the application of giant unilamellar vesicles (GUV) lipid bilayer model. The major difficulty associated with the application of the model is the statistical character of GUV population with respect to their size and the homogeneity of lipid bilayer composition, if a mixture of lipids is used. In the paper, the bending rigidity coefficient was measured using the fluorescence-enhanced flicker-noise spectroscopy. In the paper, the bending rigidity coefficient was determined for large populations of 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine and 1,2-dioleoyl-sn-glycero-3-phosphocholine vesicles. The quantity of obtained experimental data allows to perform statistical analysis aiming at the identification of the distribution, which is the most appropriate for the calculation of the value of the membrane bending rigidity coefficient. It has been demonstrated that the bending rigidity coefficient is characterized by an asymmetrical distribution, which is well approximated with the gamma distribution. Since there are no biophysical reasons for that we propose to use the difference between normal and gamma fits as a measure of the homogeneity of vesicle population. In addition, the effect of a fluorescent label and types of instrumental setups on determined values has been tested. Obtained results show that the value of the bending rigidity coefficient does not depend on the type of a fluorescent label nor on the type of microscope used.
FGFR1/3 tyrosine kinase fusions define a unique molecular subtype of non-small cell lung cancer.
Wang, Rui; Wang, Lei; Li, Yuan; Hu, Haichuan; Shen, Lei; Shen, Xuxia; Pan, Yunjian; Ye, Ting; Zhang, Yang; Luo, Xiaoyang; Zhang, Yiliang; Pan, Bin; Li, Bin; Li, Hang; Zhang, Jie; Pao, William; Ji, Hongbin; Sun, Yihua; Chen, Haiquan
2014-08-01
The fibroblast growth factor receptor (FGFR)-3 fusion genes have been recently demonstrated in a subset of non-small cell lung cancer (NSCLC). To aid in identification and treatment of these patients, we examined the frequency, clinicopathologic characteristics, and treatment outcomes of patients who had NSCLC with or without FGFR fusions. Fourteen known FGFR fusion variants, including FGFR1, FGFR2, and FGFR3, were detected by RT-PCR and verified by direct sequencing in 1,328 patients with NSCLC. All patients were also analyzed for mutations in EGFR, KRAS, HER2, BRAF, ALK, RET, and ROS1. Clinical characteristics, including age, sex, smoking status, stage, subtypes of lung adenocarcinoma, relapse-free survival, and overall survival, were collected. Of 1,328 tumors screened, two (0.2%) were BAG4-FGFR1 fusion and 15 (1.1%) were FGFR3-TACC3 fusion. Six of 1,016 patients with lung adenocarcinoma were FGFR3-TACC3 fusions and 11 of 312 lung squamous cell carcinoma harbored BAG4-FGFR1 or FGFR3-TACC3 fusions. Compared with the FGFR fusion-negative group, patients with FGFR fusions were more likely to be smokers (94.1%, 16 of 17 patients, P < 0.001), significantly associated with larger tumor (>3 cm; 88.2%, 15 of 17 patients, P < 0.001) and with a tendency to be more poorly differentiated (53.9%, nine of 17 patients, P = 0.095). FGFR fusions define a molecular subset of NSCLC with distinct clinical characteristics. FGFR is a druggable target and patients with FGFR fusions may benefit from FGFR-targeted therapy, which needs further clinical investigation. ©2014 American Association for Cancer Research.
Serial-to-parallel color-TV converter
NASA Technical Reports Server (NTRS)
Doak, T. W.; Merwin, R. B.; Zuckswert, S. E.; Sepper, W.
1976-01-01
Solid analog-to-digital converter eliminates flicker and problems with time base stability and gain variation in sequential color TV cameras. Device includes 3-bit delta modulator; two-field memory; timing, switching, and sync network; and three 3-bit delta demodulators
ERIC Educational Resources Information Center
Schmalz, Georgann
1985-01-01
Building specifications for birdhouses (nesting boxes) are given for 11 species (chickadee, titmouse, nuthatch, Carolina wren, house wren, downy woodpecker, hairy woodpecker, flicker, bluebird, screech owl, and wood duck) including length, width, depth, entrance diameter, and height above the ground. Pointers for construction, materials, and…
NASA Astrophysics Data System (ADS)
Zhang, Xiaojie; Zeng, Qiming; Jiao, Jian; Zhang, Jingfa
2016-01-01
Repeat-pass Interferometric Synthetic Aperture Radar (InSAR) is a technique that can be used to generate DEMs. But the accuracy of InSAR is greatly limited by geometrical distortions, atmospheric effect, and decorrelations, particularly in mountainous areas, such as western China where no high quality DEM has so far been accomplished. Since each of InSAR DEMs generated using data of different frequencies and baselines has their own advantages and disadvantages, it is therefore very potential to overcome some of the limitations of InSAR by fusing Multi-baseline and Multi-frequency Interferometric Results (MMIRs). This paper proposed a fusion method based on Extended Kalman Filter (EKF), which takes the InSAR-derived DEMs as states in prediction step and the flattened interferograms as observations in control step to generate the final fused DEM. Before the fusion, detection of layover and shadow regions, low-coherence regions and regions with large height error is carried out because MMIRs in these regions are believed to be unreliable and thereafter are excluded. The whole processing flow is tested with TerraSAR-X and Envisat ASAR datasets. Finally, the fused DEM is validated with ASTER GDEM and national standard DEM of China. The results demonstrate that the proposed method is effective even in low coherence areas.
Violent flickering in Black Holes
NASA Astrophysics Data System (ADS)
2008-10-01
Unique observations of the flickering light from the surroundings of two black holes provide new insights into the colossal energy that flows at their hearts. By mapping out how well the variations in visible light match those in X-rays on very short timescales, astronomers have shown that magnetic fields must play a crucial role in the way black holes swallow matter. Flickering black hole ESO PR Photo 36/08 Flickering black hole Like the flame from a candle, light coming from the surroundings of a black hole is not constant -- it flares, sputters and sparkles. "The rapid flickering of light from a black hole is most commonly observed at X-ray wavelengths," says Poshak Gandhi, who led the international team that reports these results. "This new study is one of only a handful to date that also explore the fast variations in visible light, and, most importantly how these fluctuations relate to those in X-rays." The observations tracked the shimmering of the black holes simultaneously using two different instruments, one on the ground and one in space. The X-ray data were taken using NASA's Rossi X-ray Timing Explorer satellite. The visible light was collected with the high speed camera ULTRACAM, a visiting instrument at ESO's Very Large Telescope (VLT), recording up to 20 images a second. ULTRACAM was developed by team members Vik Dhillon and Tom Marsh. "These are among the fastest observations of a black hole ever obtained with a large optical telescope," says Dhillon. To their surprise, astronomers discovered that the brightness fluctuations in the visible light were even more rapid than those seen in X-rays. In addition, the visible-light and X-ray variations were found not to be simultaneous, but to follow a repeated and remarkable pattern: just before an X-ray flare the visible light dims, and then surges to a bright flash for a tiny fraction of a second before rapidly decreasing again. None of this radiation emerges directly from the black hole, but from the intense energy flows of electrically charged matter in its vicinity. The environment of a black hole is constantly being reshaped by a riotous mêlée of strong and competing forces such as gravity, magnetism and explosive pressure. As a result, light emitted by the hot flows of matter varies in brightness in a muddled and haphazard way. "But the pattern found in this new study possesses a stable structure that stands out amidst an otherwise chaotic variability, and so, it can yield vital clues about the dominant underlying physical processes in action," says team member Andy Fabian. The visible-light emission from the neighbourhoods of black holes was widely thought to be a secondary effect, with a primary X-ray outburst illuminating the surrounding gas that subsequently shone in the visible range. But if this were so, any visible-light variations would lag behind the X-ray variability, and would be much slower to peak and fade away. "The rapid visible-light flickering now discovered immediately rules out this scenario for both systems studied," asserts Gandhi. "Instead the variations in the X-ray and visible light output must have some common origin, and one very close to the black hole itself." Strong magnetic fields represent the best candidate for the dominant physical process. Acting as a reservoir, they can soak up the energy released close to the black hole, storing it until it can be discharged either as hot (multi-million degree) X-ray emitting plasma, or as streams of charged particles travelling at close to the speed of light. The division of energy into these two components can result in the characteristic pattern of X-ray and visible-light variability.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ryutov, D D; Thio, Y F
In a fusion reactor based on the Magnetized Target Fusion approach, the permanent power supply has to deliver currents up to a few mega-amperes to the target dropped into the reaction chamber. All the structures situated around the target will be destroyed after every pulse and have to be replaced at a frequency of 1 to 10 Hz. In this paper, an approach based on the use of spherical blanket surrounding the target, and pulsed plasma electrodes connecting the target to the power supply, is discussed. A brief physic analysis of the processes associated with creation of plasma electrodes ismore » discussed.« less
Next-generation laser for inertial confinement fusion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marshall, C; Bibeau, C; Bayramian, A
1998-03-13
We are developing and building the ''Mercury'' laser system as the first in a series of a new generation of diode-pumped solid-state lasers (DPSSL) for advanced high energy density (HED) physics experiments at LLNL. Mercury will be the first integrated demonstration of a scalable laser architecture compatible with advanced Inertial Confinement Fusion (ICF) goals. Primary performance goals include 10% efficiencies at 10 Hz and a <10 ns pulse with l {omega} energies of 100 J and with 2 {omega}/3 {omega} frequency conversion. Achieving this performance will provide a near term capability for HED experiments and prove the potential of DPSSLsmore » for inertial fusion energy (IFE).« less
Frequency domain surface EMG sensor fusion for estimating finger forces.
Potluri, Chandrasekhar; Kumar, Parmod; Anugolu, Madhavi; Urfer, Alex; Chiu, Steve; Naidu, D; Schoen, Marco P
2010-01-01
Extracting or estimating skeletal hand/finger forces using surface electro myographic (sEMG) signals poses many challenges due to cross-talk, noise, and a temporal and spatially modulated signal characteristics. Normal sEMG measurements are based on single sensor data. In this paper, array sensors are used along with a proposed sensor fusion scheme that result in a simple Multi-Input-Single-Output (MISO) transfer function. Experimental data is used along with system identification to find this MISO system. A Genetic Algorithm (GA) approach is employed to optimize the characteristics of the MISO system. The proposed fusion-based approach is tested experimentally and indicates improvement in finger/hand force estimation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kung, C. C.; Kramer, G. J.; Johnson, E.
Reflectometry, which uses the microwave radar technique to probe the magnetically confined fusion plasmas, is a very powerful tool to observe the density fluctuations in the fusion plasmas. Typically, two or more microwave beams of different frequencies are used to study the plasma density fluctuations. The frequency separation between these two beams of the PPPL designed reflectometer system upgrade on the DIII-D tokamak can be varied over 18 GHz. Due to the performance of the associated electronics, the local oscillator (LO) power level at the LO port of the I/Q demodulator suffers more than 12 dB of power fluctuations whenmore » the frequency separation is varied. Thus, the I/Q demodulator performance is impaired. In order to correct this problem, a power leveling circuit is introduced in the PPPL upgrade. According to the test results, the LO power fluctuation was regulated to be within 1 dB for greater than 16 dB of input power variation over the full dynamic bandwidth of the receiver.« less
Regulation of exocytotic fusion by cell inflation.
Solsona, C; Innocenti, B; Fernández, J M
1998-01-01
We have inflated patch-clamped mast cells by 3.8 +/- 1.6 times their volume by applying a hydrostatic pressure of 5-15 cm H2O to the interior of the patch pipette. Inflation did not cause changes in the cell membrane conductance and caused only a small reversible change in the cell membrane capacitance (36 +/- 5 fF/cm H2O). The specific cell membrane capacitance of inflated cells was found to be 0.5 microF/cm2. High-resolution capacitance recordings showed that inflation reduced the frequency of exocytotic fusion events by approximately 70-fold, with the remaining fusion events showing an unusual time course. Shortly after the pressure was returned to 0 cm H2O, mast cells regained their normal size and appearance and degranulated completely, even after remaining inflated for up to 60 min. We interpret these observations as an indication that inflated mast cells reversibly disassemble the structures that regulate exocytotic fusion. Upon returning to its normal size, the cell cytosol reassembles the fusion pore scaffolds and allows exocytosis to proceed, suggesting that exocytotic fusion does not require soluble proteins. Reassembly of the fusion pore can be prevented by inflating the cells with solutions containing the protease pronase, which completely blocked exocytosis. We also interpret these results as evidence that the activity of the fusion pore is sensitive to the tension of the plasma membrane. PMID:9533718
Impact of fluorescent protein fusions on the bacterial flagellar motor.
Heo, M; Nord, A L; Chamousset, D; van Rijn, E; Beaumont, H J E; Pedaci, F
2017-10-03
Fluorescent fusion proteins open a direct and unique window onto protein function. However, they also introduce the risk of perturbation of the function of the native protein. Successful applications of fluorescent fusions therefore rely on a careful assessment and minimization of the side effects, but such insight is still lacking for many applications. This is particularly relevant in the study of the internal dynamics of motor proteins, where both the chemical and mechanical reaction coordinates can be affected. Fluorescent proteins fused to the stator of the Bacterial Flagellar Motor (BFM) have previously been used to unveil the motor subunit dynamics. Here we report the effects on single motors of three fluorescent proteins fused to the stators, all of which altered BFM behavior. The torque generated by individual stators was reduced while their stoichiometry remained unaffected. MotB fusions decreased the switching frequency and induced a novel bias-dependent asymmetry in the speed in the two directions. These effects could be mitigated by inserting a linker at the fusion point. These findings provide a quantitative account of the effects of fluorescent fusions to the stator on BFM dynamics and their alleviation- new insights that advance the use of fluorescent fusions to probe the dynamics of protein complexes.
ERIC Educational Resources Information Center
Smith, Jack L.
1989-01-01
Discusses the advantages of opening class sessions with demonstrations. Describes 11 demonstrations, including cloud formation, lather expansion, singing glassware, a flickering filament, balancing a fork and spoon, spinning an egg, television distortion, a roll race, a vortex generator, a suspended egg, and flight magic. (YP)
Studies of FAUNA at Eglin Air Force Base
2006-07-01
occasionally resulted in fires that were hot enough to kill mature pines, including the old growth pines upon which RCWs depend for cavity excavation...cardinalis NOCA Northern flicker* Colaptes auratus NOFL Northern mockingbird Mimus polyglottos NOMO Northern rough-winged swallow Stelgidopteryx
Lazar, Alexander J.; Bridge, Julia A.; Benjamin, Robert S.; Trent, Jonathan C.
2014-01-01
Purpose In pediatric alveolar rhabdomyosarcoma, the PAX3–FOXO1 and PAX7–FOXO1 gene fusions are prognostic indicators, while little is known concerning this disease in older patients. To determine whether PAX3/7–FOXO1 fusion gene status correlates with outcome in adolescent, young adult, and adult rhabdomyosarcoma patients, the histological, immunohistochemical, and clinical characteristics of 105 patients followed at The University of Texas MD Anderson Cancer Center from 1957 to 2001 were evaluated. Methods The samples were assembled into a tissue microarray, and fusion gene status was determined by fluorescence in situ hybridization using PAX3, PAX7, and FOXO1 loci-specific probes. The disease characteristics and specific gene fusion were correlated with patient outcomes using the log-rank test. Results Fifty-two percent of the samples exhibited a PAX3–FOXO1 fusion, 15% the PAX7–FOXO1 fusion, and 33% were negative for a rearrangement of these loci. The presence of PAX3/7–FOXO1 translocation was significantly associated with a higher frequency of metastatic disease. Although a statistically significant correlation between the PAX3/7–FOXO1 fusion gene status and overall survival was not identified, there was a trend toward better outcomes for patients with fusion-negative RMS. Conclusions Therefore, identification of a FOXO1 fusion appears to be an interesting tool for predicting outcomes in older rhabdomyosarcoma patients and is worth further investigations in this rare subgroup of RMS population. PMID:22089931
NASA Astrophysics Data System (ADS)
Schneider, M.; Johnson, T.; Dumont, R.; Eriksson, J.; Eriksson, L.-G.; Giacomelli, L.; Girardo, J.-B.; Hellsten, T.; Khilkevitch, E.; Kiptily, V. G.; Koskela, T.; Mantsinen, M.; Nocente, M.; Salewski, M.; Sharapov, S. E.; Shevelev, A. E.; Contributors, JET
2016-11-01
Recent JET experiments have been dedicated to the studies of fusion reactions between deuterium (D) and Helium-3 (3He) ions using neutral beam injection (NBI) in synergy with third harmonic ion cyclotron radio-frequency heating (ICRH) of the beam. This scenario generates a fast ion deuterium tail enhancing DD and D3He fusion reactions. Modelling and measuring the fast deuterium tail accurately is essential for quantifying the fusion products. This paper presents the modelling of the D distribution function resulting from the NBI+ICRF heating scheme, reinforced by a comparison with dedicated JET fast ion diagnostics, showing an overall good agreement. Finally, a sawtooth activity for these experiments has been observed and interpreted using SPOT/RFOF simulations in the framework of Porcelli’s theoretical model, where NBI+ICRH accelerated ions are found to have a strong stabilizing effect, leading to monster sawteeth.
Improving the recognition of fingerprint biometric system using enhanced image fusion
NASA Astrophysics Data System (ADS)
Alsharif, Salim; El-Saba, Aed; Stripathi, Reshma
2010-04-01
Fingerprints recognition systems have been widely used by financial institutions, law enforcement, border control, visa issuing, just to mention few. Biometric identifiers can be counterfeited, but considered more reliable and secure compared to traditional ID cards or personal passwords methods. Fingerprint pattern fusion improves the performance of a fingerprint recognition system in terms of accuracy and security. This paper presents digital enhancement and fusion approaches that improve the biometric of the fingerprint recognition system. It is a two-step approach. In the first step raw fingerprint images are enhanced using high-frequency-emphasis filtering (HFEF). The second step is a simple linear fusion process between the raw images and the HFEF ones. It is shown that the proposed approach increases the verification and identification of the fingerprint biometric recognition system, where any improvement is justified using the correlation performance metrics of the matching algorithm.
Shen, Chong; Li, Jie; Zhang, Xiaoming; Shi, Yunbo; Tang, Jun; Cao, Huiliang; Liu, Jun
2016-01-01
The different noise components in a dual-mass micro-electromechanical system (MEMS) gyroscope structure is analyzed in this paper, including mechanical-thermal noise (MTN), electronic-thermal noise (ETN), flicker noise (FN) and Coriolis signal in-phase noise (IPN). The structure equivalent electronic model is established, and an improved white Gaussian noise reduction method for dual-mass MEMS gyroscopes is proposed which is based on sample entropy empirical mode decomposition (SEEMD) and time-frequency peak filtering (TFPF). There is a contradiction in TFPS, i.e., selecting a short window length may lead to good preservation of signal amplitude but bad random noise reduction, whereas selecting a long window length may lead to serious attenuation of the signal amplitude but effective random noise reduction. In order to achieve a good tradeoff between valid signal amplitude preservation and random noise reduction, SEEMD is adopted to improve TFPF. Firstly, the original signal is decomposed into intrinsic mode functions (IMFs) by EMD, and the SE of each IMF is calculated in order to classify the numerous IMFs into three different components; then short window TFPF is employed for low frequency component of IMFs, and long window TFPF is employed for high frequency component of IMFs, and the noise component of IMFs is wiped off directly; at last the final signal is obtained after reconstruction. Rotation experimental and temperature experimental are carried out to verify the proposed SEEMD-TFPF algorithm, the verification and comparison results show that the de-noising performance of SEEMD-TFPF is better than that achievable with the traditional wavelet, Kalman filter and fixed window length TFPF methods. PMID:27258276
Shen, Chong; Li, Jie; Zhang, Xiaoming; Shi, Yunbo; Tang, Jun; Cao, Huiliang; Liu, Jun
2016-05-31
The different noise components in a dual-mass micro-electromechanical system (MEMS) gyroscope structure is analyzed in this paper, including mechanical-thermal noise (MTN), electronic-thermal noise (ETN), flicker noise (FN) and Coriolis signal in-phase noise (IPN). The structure equivalent electronic model is established, and an improved white Gaussian noise reduction method for dual-mass MEMS gyroscopes is proposed which is based on sample entropy empirical mode decomposition (SEEMD) and time-frequency peak filtering (TFPF). There is a contradiction in TFPS, i.e., selecting a short window length may lead to good preservation of signal amplitude but bad random noise reduction, whereas selecting a long window length may lead to serious attenuation of the signal amplitude but effective random noise reduction. In order to achieve a good tradeoff between valid signal amplitude preservation and random noise reduction, SEEMD is adopted to improve TFPF. Firstly, the original signal is decomposed into intrinsic mode functions (IMFs) by EMD, and the SE of each IMF is calculated in order to classify the numerous IMFs into three different components; then short window TFPF is employed for low frequency component of IMFs, and long window TFPF is employed for high frequency component of IMFs, and the noise component of IMFs is wiped off directly; at last the final signal is obtained after reconstruction. Rotation experimental and temperature experimental are carried out to verify the proposed SEEMD-TFPF algorithm, the verification and comparison results show that the de-noising performance of SEEMD-TFPF is better than that achievable with the traditional wavelet, Kalman filter and fixed window length TFPF methods.
Rms-flux relation and fast optical variability simulations of the nova-like system MV Lyr
NASA Astrophysics Data System (ADS)
Dobrotka, A.; Mineshige, S.; Ness, J.-U.
2015-03-01
The stochastic variability (flickering) of the nova-like system (subclass of cataclysmic variable) MV Lyr yields a complicated power density spectrum with four break frequencies. Scaringi et al. analysed high-cadence Kepler data of MV Lyr, taken almost continuously over 600 d, giving the unique opportunity to study multicomponent Power Density Spectra (PDS) over a wide frequency range. We modelled this variability with our statistical model based on disc angular momentum transport via discrete turbulent bodies with an exponential distribution of the dimension scale. Two different models were used, a full disc (developed from the white dwarf to the outer radius of ˜1010 cm) and a radially thin disc (a ring at a distance of ˜1010 cm from the white dwarf) that imitates an outer disc rim. We succeed in explaining the two lowest observed break frequencies assuming typical values for a disc radius of 0.5 and 0.9 times the primary Roche lobe and an α parameter of 0.1-0.4. The highest observed break frequency was also modelled, but with a rather small accretion disc with a radius of 0.3 times the primary Roche lobe and a high α value of 0.9 consistent with previous findings by Scaringi. Furthermore, the simulated light curves exhibit the typical linear rms-flux proportionality linear relation and the typical log-normal flux distribution. As the turbulent process is generating fluctuations in mass accretion that propagate through the disc, this confirms the general knowledge that the typical rms-flux relation is mainly generated by these fluctuations. In general, a higher rms is generated by a larger amount of superposed flares which is compatible with a higher mass accretion rate expressed by a larger flux.
Wang, Wen-Tao; Li, Yin; Ma, Jie; Chen, Xiao-Bing; Qin, Jian-Jun
2014-01-01
Epidermal growth factor receptor (EGFR) mutations and echinoderm microtubule associated protein like 4-anaplastic lymphoma kinase (EML4-ALK) define specific molecular subsets of lung adenocarcinomas with distinct clinical features. Our purpose was to analyze clinical features and prognostic value of EGFR gene mutations and the EML4-ALK fusion gene in lung adenocarcinoma. EGFR gene mutations and the EML4-ALK fusion gene were detected in 92 lung adenocarcinoma patients in China. Tumor marker levels before first treatment were measured by electrochemiluminescence immunoassay. EGFR mutations were found in 40.2% (37/92) of lung adenocarcinoma patients, being identified at high frequencies in never-smokers (48.3% vs. 26.5% in smokers; P=0.040) and in patients with abnormal serum carcinoembryonic antigen (CEA) levels before the initial treatment (58.3% vs. 28.6%, P=0.004). Multivariate analysis revealed that a higher serum CEA level before the initial treatment was independently associated with EGFR gene mutations (95%CI: 1.476~11.343, P=0.007). We also identified 8 patients who harbored the EML4-ALK fusion gene (8.7%, 8/92). In concordance with previous reports, younger age was a clinical feature for these (P=0.008). Seven of the positive cases were never smokers, and no coexistence with EGFR mutation was discovered. In addition, the frequency of the EML4-ALK fusion gene among patients with a serum CEA concentration below 5 ng/ml seemed to be higher than patients with a concentration over 5 ng/ml (P=0.021). No significant difference was observed for time to progression and overall survival between EML4-ALK-positive group and EML4-ALK-negative group or between patients with and without an EGFR mutation. The serum CEA level before the initial treatment may be helpful in screening population for EGFR mutations or EML4-ALK fusion gene presence in lung adenocarcinoma patients.
Next generation laser for Inertial Confinement Fusion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marshall, C.D.; Beach, J.; Bibeau, C.
1997-07-18
We are in the process of developing and building the ``Mercury`` laser system as the first in a series of a new generation of diode-pumped solid-state Inertial Confinement Fusion (ICF) lasers at LLNL. Mercury will be the first integrated demonstration of a scalable laser architecture compatible with advanced high energy density (HED) physics applications. Primary performance goals include 10% efficiencies at 10 Hz and a 1-10 ns pulse with 1{omega} energies of 100 J and with 2{omega}/3{omega} frequency conversion.
Alpha channeling in a rotating plasma.
Fetterman, Abraham J; Fisch, Nathaniel J
2008-11-14
The wave-particle alpha-channeling effect is generalized to include rotating plasma. Specifically, radio frequency waves can resonate with alpha particles in a mirror machine with ExB rotation to diffuse the alpha particles along constrained paths in phase space. Of major interest is that the alpha-particle energy, in addition to amplifying the rf waves, can directly enhance the rotation energy which in turn provides additional plasma confinement in centrifugal fusion reactors. An ancillary benefit is the rapid removal of alpha particles, which increases the fusion reactivity.
Sabatini, Angelo Maria; Genovese, Vincenzo
2014-01-01
A sensor fusion method was developed for vertical channel stabilization by fusing inertial measurements from an Inertial Measurement Unit (IMU) and pressure altitude measurements from a barometric altimeter integrated in the same device (baro-IMU). An Extended Kalman Filter (EKF) estimated the quaternion from the sensor frame to the navigation frame; the sensed specific force was rotated into the navigation frame and compensated for gravity, yielding the vertical linear acceleration; finally, a complementary filter driven by the vertical linear acceleration and the measured pressure altitude produced estimates of height and vertical velocity. A method was also developed to condition the measured pressure altitude using a whitening filter, which helped to remove the short-term correlation due to environment-dependent pressure changes from raw pressure altitude. The sensor fusion method was implemented to work on-line using data from a wireless baro-IMU and tested for the capability of tracking low-frequency small-amplitude vertical human-like motions that can be critical for stand-alone inertial sensor measurements. Validation tests were performed in different experimental conditions, namely no motion, free-fall motion, forced circular motion and squatting. Accurate on-line tracking of height and vertical velocity was achieved, giving confidence to the use of the sensor fusion method for tracking typical vertical human motions: velocity Root Mean Square Error (RMSE) was in the range 0.04–0.24 m/s; height RMSE was in the range 5–68 cm, with statistically significant performance gains when the whitening filter was used by the sensor fusion method to track relatively high-frequency vertical motions. PMID:25061835
Falsini, Benedetto; Ziccardi, Lucia; Lazzareschi, Ilaria; Ruggiero, Antonio; Placentino, Luca; Dickmann, Anna; Liotti, Lucia; Piccardi, Marco; Balestrazzi, Emilio; Colosimo, Cesare; Di Rocco, Concezio; Riccardi, Riccardo
2008-05-01
The aim of this study was to evaluate longitudinally functional and neuro-radiologic findings in childhood optic gliomas (OG), by comparing flicker visual evoked potentials (F-VEPs) with brain magnetic resonance imaging (MRI) changes. Fourteen children (age range: 1-13 years) with OGs underwent serial F-VEP, MRI and neuro-ophthalmic examinations over a 38 month (median, range: 6-76) follow-up. F-VEPs were elicited by 8 Hz sine-wave flicker stimuli presented in a mini-Ganzfeld. Contrast-enhanced MRI examinations were performed. Results of both tests were blindly assessed by independent evaluators. F-VEPs were judged to be improved, stable or worsened if changes in the amplitude and/or phase angle of the response exceeded the limits of test-retest variability (+/-90th percentile) established for the same patients. MRI results were judged to show regression, stabilization or progression of OG based on its changes in size (+/-20%) or extension. Two to seven pairs of F-VEP/MRI examinations per patient (median: 4) were collected. Based on a total of 38 pairs of F-VEP/MRI examinations, both tests agreed in showing worsening (progression), stabilization and improvement (regression) in 5, 15 and 10 cases, respectively. In 3 cases, F-VEPs showed a worsening and MRI a stabilization, while in 5 cases F-VEPs showed an improvement and MRI a stabilization. Agreement between F-VEP and MRI changes was 78.9% (95% CI: +/- 37%, K statistics = 0.67, P < 0.001). The results indicate that longitudinal F-VEP changes can predict changes in MRI-assessed OG size and extension, providing a non-invasive functional assay, complementary to neuro-imaging, for OG follow-up.
Nair, Archana A; Marmor, Michael F
2017-06-01
To study whether the ERG and other clinical findings help to distinguish between advanced hydroxychloroquine (HCQ) retinopathy and pericentral or diffuse retinitis pigmentosa (RP) with similar fundus appearance. We conducted a retrospective analysis of patients with advanced HCQ retinopathy (n = 11), pericentral RP (n = 8) and diffuse RP (n = 8). Pericentral RP was defined as having limited fundus damage and relatively normal flicker ERG time-to-peak. Diffuse RP had typical loss of the rod ERG and flicker timing delay. All patients showed reduced amplitude of the ISCEV responses in the full-field electroretinogram (ERG). Aspects of history, visual field results, fundus appearance, fundus autofluorescence and ocular coherence tomography were also compared. Relative to pericentral RP, patients with HCQ toxicity showed delayed flicker ERG time-to-peak and lower ERG amplitudes, particularly combined rod-cone responses. Relative to diffuse RP, most HCQ toxicity patients had some preserved rod ERG response, and there was no obvious predilection for rod over cone damage. In addition, patients with HCQ toxicity usually lacked markers of long-standing degeneration such as bone spicule figures or severe loss of peripheral field. History of familial disease and long-standing night blindness were specific to RP. While the early signs of HCQ damage are typically regional in the posterior pole, advanced disease is characteristically diffuse (unlike pericentral RP). This is appropriate for a systemic toxin, as is the finding that rods and cones were both affected in the ERG to a similar degree (unlike genetic rod-cone dystrophies). For patients with severe HCQ exposure and some of our discriminatory findings, and no family history or prior night blindness, HCQ toxicity is a sufficient diagnosis without invoking a second rare disease (Occam's razor).
Brasil, Alódia; Rocha, Fernando Allan de Farias; Gomes, Bruno Duarte; Oliveira, Karen Renata M; de Carvalho, Tayana Silva; Batista, Evander de Jesus O; Borges, Rosivaldo Dos Santos; Kremers, Jan; Herculano, Anderson Manoel
2017-06-01
The protective effect of a diet supplemented by the Amazonian fruit Euterpe oleracea (EO) against methylmercury (MeHg) toxicity in rat retina was studied using electroretinography (ERG) and biochemical evaluation of oxidative stress. Wistar rats were submitted to conventional diet or EO-enriched diet for 28 days. After that, each group received saline solution or 5 mg/kg/day of MeHg for 7 days. Full-field single flash, flash and flicker ERGs were evaluated in the following groups: control, EO, MeHg, and EO+MeHg. The amplitudes of the a-wave, b-wave, photopic negative response from rod and/or cone were measured by ERGs as well as the amplitudes and phases of the fundamental component of the sine-wave flicker ERG. Lipid peroxidation was determined by thiobarbituric acid reactive species. All ERG components had decreased amplitudes in the MeHg group when compared with controls. EO-enriched food had no effect on the non-intoxicated animals. The intoxicated animals and those that received the supplemented diet presented significant amplitude reductions of the cone b-wave and of the fundamental flicker component when compared with non-intoxicated control. The protective effect of the diet on scotopic conditions was only observed for bright flashes eliciting a mixed rod and cone response. There was a significant increase of lipid peroxidation in the retina from animals exposed to MeHg and EO-supplemented diet was able to prevent MeHg-induced oxidative stress in retinal tissue. These findings open up perspectives for the use of diets supplemented with EO as a protective strategy against visual damage induced by MeHg.
Enhanced Thermionic Emission and Low 1/f Noise in Exfoliated Graphene/GaN Schottky Barrier Diode.
Kumar, Ashutosh; Kashid, Ranjit; Ghosh, Arindam; Kumar, Vikram; Singh, Rajendra
2016-03-01
Temperature-dependent electrical transport characteristics of exfoliated graphene/GaN Schottky diodes are investigated and compared with conventional Ni/GaN Schottky diodes. The ideality factor of graphene/GaN and Ni/GaN diodes are measured to be 1.33 and 1.51, respectively, which is suggestive of comparatively higher thermionic emission current in graphene/GaN diode. The barrier height values for graphene/GaN diode obtained using thermionic emission model and Richardson plots are found to be 0.60 and 0.72 eV, respectively, which are higher than predicted barrier height ∼0.40 eV as per the Schottky-Mott model. The higher barrier height is attributed to hole doping of graphene due to graphene-Au interaction which shifts the Fermi level in graphene by ∼0.3 eV. The magnitude of flicker noise of graphene/GaN Schottky diode increases up to 175 K followed by its decrease at higher temperatures. This indicates that diffusion currents and barrier inhomogeneities dominate the electronic transport at lower and higher temperatures, respectively. The exfoliated graphene/GaN diode is found to have lower level of barrier inhomogeneities than conventional Ni/GaN diode, as well as earlier reported graphene/GaN diode fabricated using chemical vapor deposited graphene. The lesser barrier inhomogeneities in graphene/GaN diode results in lower flicker noise by 2 orders of magnitude as compared to Ni/GaN diode. Enhanced thermionic emission current, lower level of inhomogeneities, and reduced flicker noise suggests that graphene-GaN Schottky diodes may have the underlying trend for replacing metal-GaN Schottky diodes.
Non-Canonical Thinking for Targeting ALK-Fusion Onco-Proteins in Lung Cancer
Wu, Wei; Haderk, Franziska; Bivona, Trever G.
2017-01-01
Anaplastic lymphoma kinase (ALK) gene rearrangements have been identified in lung cancer at 3–7% frequency, thus representing an important subset of genetic lesions that drive oncogenesis in this disease. Despite the availability of multiple FDA-approved small molecule inhibitors targeting ALK fusion proteins, drug resistance to ALK kinase inhibitors is a common problem in clinic. Thus, there is an unmet need to deepen the current understanding of genomic characteristics of ALK rearrangements and to develop novel therapeutic strategies that can overcome ALK inhibitor resistance. In this review, we present the genomic landscape of ALK fusions in the context of co-occurring mutations with other cancer-related genes, pointing to the central role of genetic epistasis (gene-gene interactions) in ALK-driven advanced-stage lung cancer. We discuss the possibility of targeting druggable domains within ALK fusion partners in addition to available strategies inhibiting the ALK kinase domain directly. Finally, we examine the potential of targeting ALK fusion-specific neoantigens in combination with other treatments, a strategy that could open a new avenue for the improved treatment of ALK positive lung cancer patients. PMID:29189709
A Support Vector Machine-Based Gender Identification Using Speech Signal
NASA Astrophysics Data System (ADS)
Lee, Kye-Hwan; Kang, Sang-Ick; Kim, Deok-Hwan; Chang, Joon-Hyuk
We propose an effective voice-based gender identification method using a support vector machine (SVM). The SVM is a binary classification algorithm that classifies two groups by finding the voluntary nonlinear boundary in a feature space and is known to yield high classification performance. In the present work, we compare the identification performance of the SVM with that of a Gaussian mixture model (GMM)-based method using the mel frequency cepstral coefficients (MFCC). A novel approach of incorporating a features fusion scheme based on a combination of the MFCC and the fundamental frequency is proposed with the aim of improving the performance of gender identification. Experimental results demonstrate that the gender identification performance using the SVM is significantly better than that of the GMM-based scheme. Moreover, the performance is substantially improved when the proposed features fusion technique is applied.
Fusion product losses due to fishbone instabilities in deuterium JET plasmas
NASA Astrophysics Data System (ADS)
Kiptily, V. G.; Fitzgerald, M.; Goloborodko, V.; Sharapov, S. E.; Challis, C. D.; Frigione, D.; Graves, J.; Mantsinen, M. J.; Beaumont, P.; Garcia-Munoz, M.; Perez von Thun, C.; Rodriguez, J. F. R.; Darrow, D.; Keeling, D.; King, D.; McClements, K. G.; Solano, E. R.; Schmuck, S.; Sips, G.; Szepesi, G.; Contributors, JET
2018-01-01
During development of a high-performance hybrid scenario for future deuterium-tritium experiments on the Joint European Torus, an increased level of fast ion losses in the MeV energy range was observed during the instability of high-frequency n = 1 fishbones. The fishbones are excited during deuterium neutral beam injection combined with ion cyclotron heating. The frequency range of the fishbones, 10-25 kHz, indicates that they are driven by a resonant interaction with the NBI-produced deuterium beam ions in the energy range ⩽120 keV. The fast particle losses in a much higher energy range are measured with a fast ion loss detector, and the data show an expulsion of deuterium plasma fusion products, 1 MeV tritons and 3 MeV protons, during the fishbone bursts. An MHD mode analysis with the MISHKA code combined with the nonlinear wave-particle interaction code HAGIS shows that the loss of toroidal symmetry caused by the n = 1 fishbones affects strongly the confinement of non-resonant high energy fusion-born tritons and protons by perturbing their orbits and expelling them. This modelling is in a good agreement with the experimental data.
Fusion of infrared and visible images based on saliency scale-space in frequency domain
NASA Astrophysics Data System (ADS)
Chen, Yanfei; Sang, Nong; Dan, Zhiping
2015-12-01
A fusion algorithm of infrared and visible images based on saliency scale-space in the frequency domain was proposed. Focus of human attention is directed towards the salient targets which interpret the most important information in the image. For the given registered infrared and visible images, firstly, visual features are extracted to obtain the input hypercomplex matrix. Secondly, the Hypercomplex Fourier Transform (HFT) is used to obtain the salient regions of the infrared and visible images respectively, the convolution of the input hypercomplex matrix amplitude spectrum with a low-pass Gaussian kernel of an appropriate scale which is equivalent to an image saliency detector are done. The saliency maps are obtained by reconstructing the 2D signal using the original phase and the amplitude spectrum, filtered at a scale selected by minimizing saliency map entropy. Thirdly, the salient regions are fused with the adoptive weighting fusion rules, and the nonsalient regions are fused with the rule based on region energy (RE) and region sharpness (RS), then the fused image is obtained. Experimental results show that the presented algorithm can hold high spectrum information of the visual image, and effectively get the thermal targets information at different scales of the infrared image.
Kinetic electromagnetic instabilities in an ITB plasma with weak magnetic shear
NASA Astrophysics Data System (ADS)
Chen, W.; Yu, D. L.; Ma, R. R.; Shi, P. W.; Li, Y. Y.; Shi, Z. B.; Du, H. R.; Ji, X. Q.; Jiang, M.; Yu, L. M.; Yuan, B. S.; Li, Y. G.; Yang, Z. C.; Zhong, W. L.; Qiu, Z. Y.; Ding, X. T.; Dong, J. Q.; Wang, Z. X.; Wei, H. L.; Cao, J. Y.; Song, S. D.; Song, X. M.; Liu, Yi.; Yang, Q. W.; Xu, M.; Duan, X. R.
2018-05-01
Kinetic Alfvén and pressure gradient driven instabilities are very common in magnetized plasmas, both in space and the laboratory. These instabilities will be easily excited by energetic particles (EPs) and/or pressure gradients in present-day fusion and future burning plasmas. This will not only cause the loss and redistribution of the EPs, but also affect plasma confinement and transport. Alfvénic ion temperature gradient (AITG) instabilities with the frequency ω_BAE<ω<ω_TAE and the toroidal mode numbers n=2{-}8 are found to be unstable in NBI internal transport barrier plasmas with weak shear and low pressure gradients, where ω_BAE and ω_TAE are the frequencies of the beta- and toroidicity-induced Alfvén eigenmodes, respectively. The measured results are consistent with the general fishbone-like dispersion relation and kinetic ballooning mode equation, and the modes become more unstable the smaller the magnetic shear is in low pressure gradient regions. The interaction between AITG activity and EPs also needs to be investigated with greater attention in fusion plasmas, such as ITER (Tomabechi and The ITER Team 1991 Nucl. Fusion 31 1135), since these fluctuations can be enhanced by weak magnetic shear and EPs.
Improved Anti-Treg Vaccination Targeting Foxp3 Efficiently Decreases Regulatory T Cells in Mice.
Mousavi Niri, Neda; Memarnejadian, Arash; Pilehvar-Soltanahmadi, Younes; Agha Sadeghi, Mohammadreza; Mahdavi, Mehdi; Kheshtchin, Nasim; Arab, Samaneh; Namdar, Afshin; Jadidi, Farhad; Zarghami, Nosratollah; Hajati, Jamshid
2016-09-01
The critical role of regulatory T (Treg) cells in dampening immune responses against tumor cells is apparent. Therefore, several methods have been introduced for eliminating Treg. Among them, inducing immune responses against Treg cells expressing Foxp3 transcription factor is a hopeful approach to decrease the frequency of Tregs. In current study, we used the chimeric FoxP3-Fc(IgG) fusion construct/protein to effectively stimulate the immune responses against Treg cells. Previously constructed FoxP3-Fc(IgG) DNA vaccine and its protein counterpart were injected into C57BL/6 mice in a prime/boost regimen. After 2 weeks, the mice were killed to measure the frequency of Tregs in their spleens, as well as analyze their specific cytokine production, T-cell proliferation, and CD8 T-cell cytotoxicity against FoxP3 protein. FACS analysis of FoxP3 CD4 cells in splenocytes revealed the efficiency of FoxP3 DNA-prime protein-boost strategy to decrease the Treg cells and further showed considerable superiority of Fc(IgG) fusion strategy. This significant reduction in Treg frequency was also concomitant with higher FoxP3-specific CTL and Th1 responses in FoxP3-Fc vaccinated animals. Prime/boost vaccination against FoxP3 in addition to enhanced antigen presentation by means of Fc fusion strategy could be successfully considered for Treg depletion studies. Validity of this approach should be experimentally tested in preclinical tumor models.
Kobayashi, Makoto; Sakakibara, Tomohiro; Inoue, Akira; Fukuhara, Tatsuro; Sasano, Hironobu; Ichinose, Masakazu; Nukiwa, Toshihiro
2014-01-01
A novel fusion gene that comprises the echinoderm microtubule-associated protein-like 4 (EML4) and anaplastic lymphoma kinase (ALK) genes was recently identified in non-small cell lung cancer (NSCLC), particularly in adenocarcinoma. A specific ALK inhibitor has been shown to exert anti-tumor effects in NSCLC with the EML4-ALK fusion gene. Previous reports suggested an EML4-ALK incidence of approximately 5% in a pan-NSCLC population, with an increased frequency in younger patients, but an appropriate strategy for further selecting patients with the EML4-ALK fusion gene remains unknown. Patients, 55 years of age or younger, who were diagnosed with NSCLC without typical squamous cell carcinoma features at our institute were retrospectively evaluated. The tumor specimens were examined by immunohistochemistry for the EML4-ALK fusion gene and by polymerase chain reaction for epidermal growth factor receptor (EGFR) mutations. Between January 2004 and September 2011, the EML4-ALK fusion gene was detected in 19.6% (9/46) of patients. The fusion gene incidence increased to 31% (9/29) when patients with EGFR mutations were excluded. The EML4-ALK fusion gene was further detected in 2 cases of undifferentiated cell carcinoma. EML4-ALK fusion gene examinations could be more effectively performed by selecting young NSCLC patients without EGFR mutations, whereas selection on the basis of a non-smoking or adenocarcinoma history, as reported in previous studies, may not correctly identify the patient groups with potential EML4-ALK fusion gene. Copyright © 2013 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.
2015 Inverter Workshop | Photovoltaic Research | NREL
Utility PV Inverters-Ron Vidano, Advanced Energy Module Level Power Electronics-Jack Flicker (Chair ), Sandia National Laboratories Standardization and Reliability Testing of Module-Level Power Electronics Failure Modes in Inverters-Diganta Das, CALCE Corrosion of Electronics-Rob Sorensen, Sandia National
Macular pigment optical density is related to serum lutein in retinitis pigmentosa
USDA-ARS?s Scientific Manuscript database
Purpose: To determine whether macular pigment optical density (MPOD) is related to the degree of cystoid macular edema (CME) in patients with retinitis pigmentosa. Methods: We measured MPOD with heterochromatic flicker photometry and central foveal retinal thickness with optical coherence tomography...
ERIC Educational Resources Information Center
Robertson, C. T.
1973-01-01
Discusses theories underlying the phenomena of solution viscosities, involving the Jones and Dole equation, B-coefficient determination, and flickering cluster model. Indicates that viscosity measurements provide a basis for the study of the structural effects of ions in aqueous solutions and are applicable in teaching high school chemistry. (CC)
Collins, Jennifer; Pecher, Diane; Zeelenberg, René; Coulson, Seana
2011-01-01
The perceptual modalities associated with property words, such as flicker or click, have previously been demonstrated to affect subsequent property verification judgments (Pecher et al., 2003). Known as the conceptual modality switch effect, this finding supports the claim that brain systems for perception and action help subserve the representation of concepts. The present study addressed the cognitive and neural substrate of this effect by recording event-related potentials (ERPs) as participants performed a property verification task with visual or auditory properties in key trials. We found that for visual property verifications, modality switching was associated with an increased amplitude N400. For auditory verifications, switching led to a larger late positive complex. Observed ERP effects of modality switching suggest property words access perceptual brain systems. Moreover, the timing and pattern of the effects suggest perceptual systems impact the decision-making stage in the verification of auditory properties, and the semantic stage in the verification of visual properties. PMID:21713128
Collins, Jennifer; Pecher, Diane; Zeelenberg, René; Coulson, Seana
2011-01-01
The perceptual modalities associated with property words, such as flicker or click, have previously been demonstrated to affect subsequent property verification judgments (Pecher et al., 2003). Known as the conceptual modality switch effect, this finding supports the claim that brain systems for perception and action help subserve the representation of concepts. The present study addressed the cognitive and neural substrate of this effect by recording event-related potentials (ERPs) as participants performed a property verification task with visual or auditory properties in key trials. We found that for visual property verifications, modality switching was associated with an increased amplitude N400. For auditory verifications, switching led to a larger late positive complex. Observed ERP effects of modality switching suggest property words access perceptual brain systems. Moreover, the timing and pattern of the effects suggest perceptual systems impact the decision-making stage in the verification of auditory properties, and the semantic stage in the verification of visual properties.
Advantages of statistical analysis of giant vesicle flickering for bending elasticity measurements.
Méléard, P; Pott, T; Bouvrais, H; Ipsen, J H
2011-10-01
We show how to greatly improve precision when determining bending elasticity of giant unilamellar vesicles. Taking advantage of the well-known quasi-spherical model of liposome flickering, we analyze the full probability distributions of the configurational fluctuations instead of limiting the analysis to the second moment measurements only as usually done in previously published works. This leads to objective criteria to reject vesicles that do not behave according to the model. As a result, the confidence in the bending elasticity determination of individual vesicles that fit the model is improved and, consequently, the reproducibility of this measurement for a given membrane system. This approach uncovers new possibilities for bending elasticity studies like detection of minute influences by solutes in the buffer or into the membrane. In the same way, we are now able to detect the inhomogeneous behavior of giant vesicle systems such as the hazardous production of peroxide in bilayers containing fluorescent dyes. © EDP Sciences / Società Italiana di Fisica / Springer-Verlag 2011