Sample records for floating gate roms

  1. Memory operations in Au nanoparticle single-electron transistors with floating gate electrodes

    NASA Astrophysics Data System (ADS)

    Azuma, Yasuo; Sakamoto, Masanori; Teranishi, Toshiharu; Majima, Yutaka

    2016-11-01

    Floating gate memory operations are demonstrated in a single-electron transistor (SET) fabricated by a chemical assembly using the Au nanogap electrodes and the chemisorbed Au nanoparticles. By applying pulse voltages to the control gate, phase shifts were clearly and stably observed both in the Coulomb oscillations and in the Coulomb diamonds. Writing and erasing operations on the floating gate memory were reproducibly observed, and the charges on the floating gate electrodes were maintained for at least 12 h. By considering the capacitance of the floating gate electrode, the number of electrons in the floating gate electrode was estimated as 260. Owing to the stability of the fabricated SET, these writing and erasing operations on the floating gate memory can be applied to reconfigurable SET circuits fabricated by a chemically assembled technique.

  2. Extraction of the gate capacitance coupling coefficient in floating gate non-volatile memories: Statistical study of the effect of mismatching between floating gate memory and reference transistor in dummy cell extraction methods

    NASA Astrophysics Data System (ADS)

    Rafhay, Quentin; Beug, M. Florian; Duane, Russell

    2007-04-01

    This paper presents an experimental comparison of dummy cell extraction methods of the gate capacitance coupling coefficient for floating gate non-volatile memory structures from different geometries and technologies. These results show the significant influence of mismatching floating gate devices and reference transistors on the extraction of the gate capacitance coupling coefficient. In addition, it demonstrates the accuracy of the new bulk bias dummy cell extraction method and the importance of the β function, introduced recently in [Duane R, Beug F, Mathewson A. Novel capacitance coupling coefficient measurement methodology for floating gate non-volatile memory devices. IEEE Electr Dev Lett 2005;26(7):507-9], to determine matching pairs of floating gate memory and reference transistor.

  3. DIFMOS - A floating-gate electrically erasable nonvolatile semiconductor memory technology. [Dual Injector Floating-gate MOS

    NASA Technical Reports Server (NTRS)

    Gosney, W. M.

    1977-01-01

    Electrically alterable read-only memories (EAROM's) or reprogrammable read-only memories (RPROM's) can be fabricated using a single-level metal-gate p-channel MOS technology with all conventional processing steps. Given the acronym DIFMOS for dual-injector floating-gate MOS, this technology utilizes the floating-gate technique for nonvolatile storage of data. Avalanche injection of hot electrons through gate oxide from a special injector diode in each bit is used to charge the floating gates. A second injector structure included in each bit permits discharge of the floating gate by avalanche injection of holes through gate oxide. The overall design of the DIFMOS bit is dictated by the physical considerations required for each of the avalanche injector types. The end result is a circuit technology which can provide fully decoded bit-erasable EAROM-type circuits using conventional manufacturing techniques.

  4. Effects of floating gate structures on the two-dimensional electron gas density and electron mobility in AlGaN/AlN/GaN heterostructure field-effect transistors

    NASA Astrophysics Data System (ADS)

    Zhao, Jingtao; Zhao, Zhenguo; Chen, Zidong; Lin, Zhaojun; Xu, Fukai

    2017-12-01

    In this study, we have investigated the electrical properties of the AlGaN/AlN/GaN heterostructure field-effect transistors (HFETs) with floating gate structures using the measured capacitancevoltage (C-V) and current-voltage (I-V) characteristics. It is found that the two-dimensional electron gas (2DEG) density under the central gate cannot be changed by the floating gate structures. However, the floating gate structures can cause the strain variation in the barrier layer, which lead to the non-uniform distribution of the polarization charges, then induce a polarization Coulomb field and scatter the 2DEG. More floating gate structures and closer distance between the floating gates and the central gate will result in stronger scattering effect of the 2DEG.

  5. Investigation of field induced trapping on floating gates

    NASA Technical Reports Server (NTRS)

    Gosney, W. M.

    1975-01-01

    The development of a technology for building electrically alterable read only memories (EAROMs) or reprogrammable read only memories (RPROMs) using a single level metal gate p channel MOS process with all conventional processing steps is outlined. Nonvolatile storage of data is achieved by the use of charged floating gate electrodes. The floating gates are charged by avalanche injection of hot electrodes through gate oxide, and discharged by avalanche injection of hot holes through gate oxide. Three extra diffusion and patterning steps are all that is required to convert a standard p channel MOS process into a nonvolatile memory process. For identification, this nonvolatile memory technology was given the descriptive acronym DIFMOS which stands for Dual Injector, Floating gate MOS.

  6. Hardware Implementation of 32-Bit High-Speed Direct Digital Frequency Synthesizer

    PubMed Central

    Ibrahim, Salah Hasan; Ali, Sawal Hamid Md.; Islam, Md. Shabiul

    2014-01-01

    The design and implementation of a high-speed direct digital frequency synthesizer are presented. A modified Brent-Kung parallel adder is combined with pipelining technique to improve the speed of the system. A gated clock technique is proposed to reduce the number of registers in the phase accumulator design. The quarter wave symmetry technique is used to store only one quarter of the sine wave. The ROM lookup table (LUT) is partitioned into three 4-bit sub-ROMs based on angular decomposition technique and trigonometric identity. Exploiting the advantages of sine-cosine symmetrical attributes together with XOR logic gates, one sub-ROM block can be removed from the design. These techniques, compressed the ROM into 368 bits. The ROM compressed ratio is 534.2 : 1, with only two adders, two multipliers, and XOR-gates with high frequency resolution of 0.029 Hz. These techniques make the direct digital frequency synthesizer an attractive candidate for wireless communication applications. PMID:24991635

  7. Radiation Issues and Applications of Floating Gate Memories

    NASA Technical Reports Server (NTRS)

    Scheick, L. Z.; Nguyen, D. N.

    2000-01-01

    The radiation effects that affect various systems that comprise floating gate memories are presented. The wear-out degradation results of unirradiated flash memories are compared to irradiated flash memories. The procedure analyzes the failure to write and erase caused by wear-out and degradation of internal charge pump circuits. A method is described for characterizing the radiation effects of the floating gate itself. The rate dependence, stopping power dependence, SEU susceptibility and applications of floating gate in radiation environment are presented. The ramifications for dosimetry and cell failure are discussed as well as for the long term use aspects of non-volatile memories.

  8. A semi-floating gate memory based on van der Waals heterostructures for quasi-non-volatile applications

    NASA Astrophysics Data System (ADS)

    Liu, Chunsen; Yan, Xiao; Song, Xiongfei; Ding, Shijin; Zhang, David Wei; Zhou, Peng

    2018-05-01

    As conventional circuits based on field-effect transistors are approaching their physical limits due to quantum phenomena, semi-floating gate transistors have emerged as an alternative ultrafast and silicon-compatible technology. Here, we show a quasi-non-volatile memory featuring a semi-floating gate architecture with band-engineered van der Waals heterostructures. This two-dimensional semi-floating gate memory demonstrates 156 times longer refresh time with respect to that of dynamic random access memory and ultrahigh-speed writing operations on nanosecond timescales. The semi-floating gate architecture greatly enhances the writing operation performance and is approximately 106 times faster than other memories based on two-dimensional materials. The demonstrated characteristics suggest that the quasi-non-volatile memory has the potential to bridge the gap between volatile and non-volatile memory technologies and decrease the power consumption required for frequent refresh operations, enabling a high-speed and low-power random access memory.

  9. Ambipolar organic thin-film transistor-based nano-floating-gate nonvolatile memory

    NASA Astrophysics Data System (ADS)

    Han, Jinhua; Wang, Wei; Ying, Jun; Xie, Wenfa

    2014-01-01

    An ambipolar organic thin-film transistor-based nano-floating-gate nonvolatile memory was demonstrated, with discrete distributed gold nanoparticles, tetratetracontane (TTC), pentacene as the floating-gate layer, tunneling layer, and active layer, respectively. The electron traps at the TTC/pentacene interface were significantly suppressed, which resulted in an ambipolar operation in present memory. As both electrons and holes were supplied in the channel and trapped in the floating-gate by programming/erasing operations, respectively, i.e., one type of charge carriers was used to overwrite the other, trapped, one, a large memory window, extending on both sides of the initial threshold voltage, was realized.

  10. A Programmable and Configurable Mixed-Mode FPAA SoC

    DTIC Science & Technology

    2016-03-17

    A Programmable and Configurable Mixed-Mode FPAA SoC Sahil Shah, Sihwan Kim, Farhan Adil, Jennifer Hasler, Suma George, Michelle Collins, Richard...Abstract: The authors present a Floating-Gate based, System-On-Chip large-scale Field- Programmable Analog Array IC that integrates divergent concepts...Floating-Gate, SoC, Command Word Classification This paper presents a Floating-Gate (FG) based, System- On-Chip (SoC) large-scale Field- Programmable

  11. Solution-processed nanoparticle super-float-gated organic field-effect transistor as un-cooled ultraviolet and infrared photon counter.

    PubMed

    Yuan, Yongbo; Dong, Qingfeng; Yang, Bin; Guo, Fawen; Zhang, Qi; Han, Ming; Huang, Jinsong

    2013-01-01

    High sensitivity photodetectors in ultraviolet (UV) and infrared (IR) range have broad civilian and military applications. Here we report on an un-cooled solution-processed UV-IR photon counter based on modified organic field-effect transistors. This type of UV detectors have light absorbing zinc oxide nanoparticles (NPs) sandwiched between two gate dielectric layers as a floating gate. The photon-generated charges on the floating gate cause high resistance regions in the transistor channel and tune the source-drain output current. This "super-float-gating" mechanism enables very high sensitivity photodetectors with a minimum detectable ultraviolet light intensity of 2.6 photons/μm(2)s at room temperature as well as photon counting capability. Based on same mechansim, infrared photodetectors with lead sulfide NPs as light absorbing materials have also been demonstrated.

  12. P-channel differential multiple-time programmable memory cells by laterally coupled floating metal gate fin field-effect transistors

    NASA Astrophysics Data System (ADS)

    Wang, Tai-Min; Chien, Wei-Yu; Hsu, Chia-Ling; Lin, Chrong Jung; King, Ya-Chin

    2018-04-01

    In this paper, we present a new differential p-channel multiple-time programmable (MTP) memory cell that is fully compatible with advanced 16 nm CMOS fin field-effect transistors (FinFET) logic processes. This differential MTP cell stores complementary data in floating gates coupled by a slot contact structure, which make different read currents possible on a single cell. In nanoscale CMOS FinFET logic processes, the gate dielectric layer becomes too thin to retain charges inside floating gates for nonvolatile data storage. By using a differential architecture, the sensing window of the cell can be extended and maintained by an advanced blanket boost scheme. The charge retention problem in floating gate cells can be improved by periodic restoring lost charges when significant read window narrowing occurs. In addition to high programming efficiency, this p-channel MTP cells also exhibit good cycling endurance as well as disturbance immunity. The blanket boost scheme can remedy the charge loss problem under thin gate dielectrics.

  13. Nonvolatile memory with Co-SiO2 core-shell nanocrystals as charge storage nodes in floating gate

    NASA Astrophysics Data System (ADS)

    Liu, Hai; Ferrer, Domingo A.; Ferdousi, Fahmida; Banerjee, Sanjay K.

    2009-11-01

    In this letter, we reported nanocrystal floating gate memory with Co-SiO2 core-shell nanocrystal charge storage nodes. By using a water-in-oil microemulsion scheme, Co-SiO2 core-shell nanocrystals were synthesized and closely packed to achieve high density matrix in the floating gate without aggregation. The insulator shell also can help to increase the thermal stability of the nanocrystal metal core during the fabrication process to improve memory performance.

  14. Observation of ambipolar switching in a silver nanoparticle single-electron transistor with multiple molecular floating gates

    NASA Astrophysics Data System (ADS)

    Yamamoto, Makoto; Shinohara, Shuhei; Tamada, Kaoru; Ishii, Hisao; Noguchi, Yutaka

    2016-03-01

    Ambipolar switching behavior was observed in a silver nanoparticle (AgNP)-based single-electron transistor (SET) with tetra-tert-butyl copper phthalocyanine (ttbCuPc) as a molecular floating gate. Depending on the wavelength of the incident light, the stability diagram shifted to the negative and positive directions along the gate voltage axis. These results were explained by the photoinduced charging of ttbCuPc molecules in the vicinity of AgNPs. Moreover, multiple device states were induced by the light irradiation at a wavelength of 600 nm, suggesting that multiple ttbCuPc molecules individually worked as a floating gate.

  15. Floating Gate sensor for in-vivo dosimetry in radiation therapies. Design and first characterization.

    NASA Astrophysics Data System (ADS)

    Faigon, A.; Martinez Vazquez, I.; Carbonetto, S.; García Inza, M.; G

    2017-01-01

    A floating gate dosimeter was designed and fabricated in a standard CMOS technology. The design guides and characterization are presented. The characterization included the controlled charging by tunneling of the floating gate, and its discharging under irradiation while measuring the transistor drain current whose change is the measure of the absorbed dose. The resolution of the obtained device is close to 1 cGy satisfying the requirements for most radiation therapies dosimetry. Pending statistical proofs, the dosimeter is a potential candidate for wide in-vivo control of radiotherapy treatments.

  16. Cycle of charge carrier states with formation and extinction of a floating gate in an ambipolar tetracyanoquaterthienoquinoid-based field-effect transistor

    NASA Astrophysics Data System (ADS)

    Itoh, Takuro; Toyota, Taro; Higuchi, Hiroyuki; Matsushita, Michio M.; Suzuki, Kentaro; Sugawara, Tadashi

    2017-03-01

    A tetracyanoquaterthienoquinoid (TCT4Q)-based field effect transistor is characterized by the ambipolar transfer characteristics and the facile shift of the threshold voltage induced by the bias stress. The trapping and detrapping kinetics of charge carriers was investigated in detail by the temperature dependence of the decay of source-drain current (ISD). We found a repeatable formation of a molecular floating gate is derived from a 'charge carrier-and-gate' cycle comprising four stages, trapping of mobile carriers, formation of a floating gate, induction of oppositely charged mobile carriers, and recombination between mobile and trapped carriers to restore the initial state.

  17. Direct probing of electron and hole trapping into nano-floating-gate in organic field-effect transistor nonvolatile memories

    NASA Astrophysics Data System (ADS)

    Cui, Ze-Qun; Wang, Shun; Chen, Jian-Mei; Gao, Xu; Dong, Bin; Chi, Li-Feng; Wang, Sui-Dong

    2015-03-01

    Electron and hole trapping into the nano-floating-gate of a pentacene-based organic field-effect transistor nonvolatile memory is directly probed by Kelvin probe force microscopy. The probing is straightforward and non-destructive. The measured surface potential change can quantitatively profile the charge trapping, and the surface characterization results are in good accord with the corresponding device behavior. Both electrons and holes can be trapped into the nano-floating-gate, with a preference of electron trapping than hole trapping. The trapped charge quantity has an approximately linear relation with the programming/erasing gate bias, indicating that the charge trapping in the device is a field-controlled process.

  18. Floating gate transistors as biosensors (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Frisbie, C. Daniel

    2016-11-01

    Electrolyte gated transistors (EGTs) are a sub-class of thin film transistors that are extremely promising for biological sensing applications. These devices employ a solid electrolyte as the gate insulator; the very large capacitance of the electrolyte results in low voltage operation and high transconductance or gain. This talk will describe the fabrication of floating gate EGTs and their use as ricin sensors. The critical performance metrics for EGTs compared with other types of TFTs will also be reviewed.

  19. Electrically Erasable Programmable Integrated Circuits for Replacement of Obsolete TTL Logic

    DTIC Science & Technology

    1991-12-01

    different discrete devices" [7]. Fowler-Nordheim Tunneling Simplified Theory. Electrons in polysilicon are usually prevented from entering SiO 2 by an...overcomes the energy barrier, the tunneling electrons will not return to the polysilicon but will be carried by the electric field, causing a current to flow...Floating Gate Transistors A floating gate transistor is an insulated-gate field effect transistor (FET) that has a gate, usually made of polysilicon , which

  20. Dual-Gate p-GaN Gate High Electron Mobility Transistors for Steep Subthreshold Slope.

    PubMed

    Bae, Jong-Ho; Lee, Jong-Ho

    2016-05-01

    A steep subthreshold slope characteristic is achieved through p-GaN gate HEMT with dual-gate structure. Obtained subthreshold slope is less than 120 μV/dec. Based on the measured and simulated data obtained from single-gate device, breakdown of parasitic floating-base bipolar transistor and floating gate charged with holes are responsible to increase abruptly in drain current. In the dual-gate device, on-current degrades with high temperature but subthreshold slope is not changed. To observe the switching speed of dual-gate device and transient response of drain current are measured. According to the transient responses of drain current, switching speed of the dual-gate device is about 10(-5) sec.

  1. MOSFET Electric-Charge Sensor

    NASA Technical Reports Server (NTRS)

    Robinson, Paul A., Jr.

    1988-01-01

    Charged-particle probe compact and consumes little power. Proposed modification enables metal oxide/semiconductor field-effect transistor (MOSFET) to act as detector of static electric charges or energetic charged particles. Thickened gate insulation acts as control structure. During measurements metal gate allowed to "float" to potential of charge accumulated in insulation. Stack of modified MOSFET'S constitutes detector of energetic charged particles. Each gate "floats" to potential induced by charged-particle beam penetrating its layer.

  2. Material parameters from frequency dispersion simulation of floating gate memory with Ge nanocrystals in HfO2

    NASA Astrophysics Data System (ADS)

    Palade, C.; Lepadatu, A. M.; Slav, A.; Lazanu, S.; Teodorescu, V. S.; Stoica, T.; Ciurea, M. L.

    2018-01-01

    Trilayer memory capacitors with Ge nanocrystals (NCs) floating gate in HfO2 were obtained by magnetron sputtering deposition on p-type Si substrate followed by rapid thermal annealing at relatively low temperature of 600 °C. The frequency dispersion of capacitance and resistance was measured in accumulation regime of Al/HfO2 gate oxide/Ge NCs in HfO2 floating gate/HfO2 tunnel oxide/SiOx/p-Si/Al memory capacitors. For simulation of the frequency dispersion a complex circuit model was used considering an equivalent parallel RC circuit for each layer of the trilayer structure. A series resistance due to metallic contacts and Si substrate was necessary to be included in the model. A very good fit to the experimental data was obtained and the parameters of each layer in the memory capacitor, i.e. capacitances and resistances were determined and in turn the intrinsic material parameters, i.e. dielectric constants and resistivities of layers were evaluated. The results are very important for the study and optimization of the hysteresis behaviour of floating gate memories based on NCs embedded in oxide.

  3. 95. Photocopied August 1978. CRIBS BEING FLOATED INTO PLACE FOR ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    95. Photocopied August 1978. CRIBS BEING FLOATED INTO PLACE FOR THE CONSTRUCTION OF THE SECOND SET (NOS. 13-16) OF COMPENSATING GATES. NOTE THE ORIGINAL FOUR GATES IN THE BACKGROUND, MAY 14, 1915. (587) - Michigan Lake Superior Power Company, Portage Street, Sault Ste. Marie, Chippewa County, MI

  4. Solution processed molecular floating gate for flexible flash memories

    NASA Astrophysics Data System (ADS)

    Zhou, Ye; Han, Su-Ting; Yan, Yan; Huang, Long-Biao; Zhou, Li; Huang, Jing; Roy, V. A. L.

    2013-10-01

    Solution processed fullerene (C60) molecular floating gate layer has been employed in low voltage nonvolatile memory device on flexible substrates. We systematically studied the charge trapping mechanism of the fullerene floating gate for both p-type pentacene and n-type copper hexadecafluorophthalocyanine (F16CuPc) semiconductor in a transistor based flash memory architecture. The devices based on pentacene as semiconductor exhibited both hole and electron trapping ability, whereas devices with F16CuPc trapped electrons alone due to abundant electron density. All the devices exhibited large memory window, long charge retention time, good endurance property and excellent flexibility. The obtained results have great potential for application in large area flexible electronic devices.

  5. Floating Gate CMOS Dosimeter With Frequency Output

    NASA Astrophysics Data System (ADS)

    Garcia-Moreno, E.; Isern, E.; Roca, M.; Picos, R.; Font, J.; Cesari, J.; Pineda, A.

    2012-04-01

    This paper presents a gamma radiation dosimeter based on a floating gate sensor. The sensor is coupled with a signal processing circuitry, which furnishes a square wave output signal, the frequency of which depends on the total dose. Like any other floating gate dosimeter, it exhibits zero bias operation and reprogramming capabilities. The dosimeter has been designed in a standard 0.6 m CMOS technology. The whole dosimeter occupies a silicon area of 450 m250 m. The initial sensitivity to a radiation dose is Hz/rad, and to temperature and supply voltage is kHz/°C and 0.067 kHz/mV, respectively. The lowest detectable dose is less than 1 rad.

  6. Solution processed molecular floating gate for flexible flash memories

    PubMed Central

    Zhou, Ye; Han, Su-Ting; Yan, Yan; Huang, Long-Biao; Zhou, Li; Huang, Jing; Roy, V. A. L.

    2013-01-01

    Solution processed fullerene (C60) molecular floating gate layer has been employed in low voltage nonvolatile memory device on flexible substrates. We systematically studied the charge trapping mechanism of the fullerene floating gate for both p-type pentacene and n-type copper hexadecafluorophthalocyanine (F16CuPc) semiconductor in a transistor based flash memory architecture. The devices based on pentacene as semiconductor exhibited both hole and electron trapping ability, whereas devices with F16CuPc trapped electrons alone due to abundant electron density. All the devices exhibited large memory window, long charge retention time, good endurance property and excellent flexibility. The obtained results have great potential for application in large area flexible electronic devices. PMID:24172758

  7. A Method for Estimating the Probability of Floating Gate Prompt Charge Loss in a Radiation Environment

    NASA Technical Reports Server (NTRS)

    Edmonds, L. D.

    2016-01-01

    Since advancing technology has been producing smaller structures in electronic circuits, the floating gates in modern flash memories are becoming susceptible to prompt charge loss from ionizing radiation environments found in space. A method for estimating the risk of a charge-loss event is given.

  8. A Method for Estimating the Probability of Floating Gate Prompt Charge Loss in a Radiation Environment

    NASA Technical Reports Server (NTRS)

    Edmonds, L. D.

    2016-01-01

    Because advancing technology has been producing smaller structures in electronic circuits, the floating gates in modern flash memories are becoming susceptible to prompt charge loss from ionizing radiation environments found in space. A method for estimating the risk of a charge-loss event is given.

  9. Ambipolar nonvolatile memory based on a quantum-dot transistor with a nanoscale floating gate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Che, Yongli; Zhang, Yating, E-mail: yating@tju.edu.cn; Song, Xiaoxian

    2016-07-04

    Using only solution processing methods, we developed ambipolar quantum-dot (QD) transistor floating-gate memory (FGM) that uses Au nanoparticles as a floating gate. Because of the bipolarity of the active channel of PbSe QDs, the memory could easily trap holes or electrons in the floating gate by programming/erasing (P/E) operations, which could shift the threshold voltage both up and down. As a result, the memory exhibited good programmable memory characteristics: a large memory window (ΔV{sub th} ∼ 15 V) and a long retention time (>10{sup 5 }s). The magnitude of ΔV{sub th} depended on both P/E voltages and the bias voltage (V{sub DS}): ΔV{sub th}more » was a cubic function to V{sub P/E} and linearly depended on V{sub DS}. Therefore, this FGM based on a QD transistor is a promising alternative to its inorganic counterparts owing to its advantages of bipolarity, high mobility, low cost, and large-area production.« less

  10. Effect of tunneling layers on the performances of floating-gate based organic thin-film transistor nonvolatile memories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Wei, E-mail: wwei99@jlu.edu.cn; Han, Jinhua; Ying, Jun

    2014-09-22

    Two types of floating-gate based organic thin-film transistor nonvolatile memories (FG-OTFT-NVMs) were demonstrated, with poly(methyl methacrylate co glycidyl methacrylate) (P(MMA-GMA)) and tetratetracontane (TTC) as the tunneling layer, respectively. Their device performances were measured and compared. In the memory with a P(MMA-GMA) tunneling layer, typical unipolar hole transport was obtained with a relatively small mobility of 0.16 cm{sup 2}/V s. The unidirectional shift of turn-on voltage (V{sub on}) due to only holes trapped/detrapped in/from the floating gate resulted in a small memory window of 12.5 V at programming/erasing voltages (V{sub P}/V{sub E}) of ±100 V and a nonzero reading voltage. Benefited from the well-ordered moleculemore » orientation and the trap-free surface of TTC layer, a considerably high hole mobility of 1.7 cm{sup 2}/V s and a visible feature of electrons accumulated in channel and trapped in floating-gate were achieved in the memory with a TTC tunneling layer. High hole mobility resulted in a high on current and a large memory on/off ratio of 600 at the V{sub P}/V{sub E} of ±100 V. Both holes and electrons were injected into floating-gate and overwritten each other, which resulted in a bidirectional V{sub on} shift. As a result, an enlarged memory window of 28.6 V at the V{sub P}/V{sub E} of ±100 V and a zero reading voltage were achieved. Based on our results, a strategy is proposed to optimize FG-OTFT-NVMs by choosing a right tunneling layer to improve the majority carrier mobility and realize ambipolar carriers injecting and trapping in the floating-gate.« less

  11. A fully on-chip fast-transient NMOS low dropout voltage regulator with quasi floating gate pass element

    NASA Astrophysics Data System (ADS)

    Wang, Han; Gou, Chao; Luo, Kai

    2017-04-01

    This paper presents a fully on-chip NMOS low-dropout regulator (LDO) for portable applications with quasi floating gate pass element and fast transient response. The quasi floating gate structure makes the gate of the NMOS transistor only periodically charged or refreshed by the charge pump, which allows the charge pump to be a small economical circuit with small silicon area. In addition, a variable reference circuit is introduced enlarging the dynamic range of error amplifier during load transient. The proposed LDO has been implemented in a 0.35 μm BCD process. From experimental results, the regulator can operate with a minimum dropout voltage of 250 mV at a maximum 1 A load and {I}{{Q}} of 395 μA. Under full-range load current step, the voltage undershoot and overshoot of the proposed LDO are reduced to 50 and 26 mV, respectively.

  12. CMOS Active-Pixel Image Sensor With Simple Floating Gates

    NASA Technical Reports Server (NTRS)

    Fossum, Eric R.; Nakamura, Junichi; Kemeny, Sabrina E.

    1996-01-01

    Experimental complementary metal-oxide/semiconductor (CMOS) active-pixel image sensor integrated circuit features simple floating-gate structure, with metal-oxide/semiconductor field-effect transistor (MOSFET) as active circuit element in each pixel. Provides flexibility of readout modes, no kTC noise, and relatively simple structure suitable for high-density arrays. Features desirable for "smart sensor" applications.

  13. Physical implication of transition voltage in organic nano-floating-gate nonvolatile memories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Shun; Gao, Xu, E-mail: wangsd@suda.edu.cn, E-mail: gaoxu@suda.edu.cn; Zhong, Ya-Nan

    High-performance pentacene-based organic field-effect transistor nonvolatile memories, using polystyrene as a tunneling dielectric and Au nanoparticles as a nano-floating-gate, show parallelogram-like transfer characteristics with a featured transition point. The transition voltage at the transition point corresponds to a threshold electric field in the tunneling dielectric, over which stored electrons in the nano-floating-gate will start to leak out. The transition voltage can be modulated depending on the bias configuration and device structure. For p-type active layers, optimized transition voltage should be on the negative side of but close to the reading voltage, which can simultaneously achieve a high ON/OFF ratio andmore » good memory retention.« less

  14. Unified random access memory (URAM) by integration of a nanocrystal floating gate for nonvolatile memory and a partially depleted floating body for capacitorless 1T-DRAM

    NASA Astrophysics Data System (ADS)

    Ryu, Seong-Wan; Han, Jin-Woo; Kim, Chung-Jin; Kim, Sungho; Choi, Yang-Kyu

    2009-03-01

    This paper describes a unified memory (URAM) that utilizes a nanocrystal SOI MOSFET for multi-functional applications of both nonvolatile memory (NVM) and capacitorless 1T-DRAM. By using a discrete storage node (Ag nanocrystal) as the floating gate of the NVM, high defect immunity and 2-bit/cell operation were achieved. The embedded nanocrystal NVM also showed 1T-DRAM operation (program/erase time = 100 ns) characteristics, which were realized by storing holes in the floating body of the SOI MOSFET, without requiring an external capacitor. Three-bit/cell operation was accomplished for different applications - 2-bits for nonvolatility and 1-bit for fast operation.

  15. Floating-gate memory based on an organic metal-insulator-semiconductor capacitor

    NASA Astrophysics Data System (ADS)

    William, S.; Mabrook, M. F.; Taylor, D. M.

    2009-08-01

    A floating gate memory element is described which incorporates an evaporated gold film embedded in the gate dielectric of a metal-insulator-semiconductor capacitor based on poly(3-hexylthiophene). On exceeding a critical amplitude in the voltage sweep, hysteresis is observed in the capacitance-voltage (C-V) and current-voltage (I-V) characteristics of the device. The anticlockwise hysteresis in C-V is consistent with strong electron trapping during the positive cycle but little hole trapping during the negative cycle. We argue that the clockwise hysteresis observed in the negative cycle of the I-V plot, arises from leakage of trapped holes through the underlying insulator to the control gate.

  16. Single layer of Ge quantum dots in HfO2 for floating gate memory capacitors.

    PubMed

    Lepadatu, A M; Palade, C; Slav, A; Maraloiu, A V; Lazanu, S; Stoica, T; Logofatu, C; Teodorescu, V S; Ciurea, M L

    2017-04-28

    High performance trilayer memory capacitors with a floating gate of a single layer of Ge quantum dots (QDs) in HfO 2 were fabricated using magnetron sputtering followed by rapid thermal annealing (RTA). The layer sequence of the capacitors is gate HfO 2 /floating gate of single layer of Ge QDs in HfO 2 /tunnel HfO 2 /p-Si wafers. Both Ge and HfO 2 are nanostructured by RTA at moderate temperatures of 600-700 °C. By nanostructuring at 600 °C, the formation of a single layer of well separated Ge QDs with diameters of 2-3 nm at a density of 4-5 × 10 15 m -2 is achieved in the floating gate (intermediate layer). The Ge QDs inside the intermediate layer are arranged in a single layer and are separated from each other by HfO 2 nanocrystals (NCs) about 8 nm in diameter with a tetragonal/orthorhombic structure. The Ge QDs in the single layer are located at the crossing of the HfO 2 NCs boundaries. In the intermediate layer, besides Ge QDs, a part of the Ge atoms is segregated by RTA at the HfO 2 NCs boundaries, while another part of the Ge atoms is present inside the HfO 2 lattice stabilizing the tetragonal/orthorhombic structure. The fabricated capacitors show a memory window of 3.8 ± 0.5 V and a capacitance-time characteristic with 14% capacitance decay in the first 3000-4000 s followed by a very slow capacitance decrease extrapolated to 50% after 10 years. This high performance is mainly due to the floating gate of a single layer of well separated Ge QDs in HfO 2 , distanced from the Si substrate by the tunnel oxide layer with a precise thickness.

  17. Multiplexed charge-locking device for large arrays of quantum devices

    NASA Astrophysics Data System (ADS)

    Puddy, R. K.; Smith, L. W.; Al-Taie, H.; Chong, C. H.; Farrer, I.; Griffiths, J. P.; Ritchie, D. A.; Kelly, M. J.; Pepper, M.; Smith, C. G.

    2015-10-01

    We present a method of forming and controlling large arrays of gate-defined quantum devices. The method uses an on-chip, multiplexed charge-locking system and helps to overcome the restraints imposed by the number of wires available in cryostat measurement systems. The device architecture that we describe here utilises a multiplexer-type scheme to lock charge onto gate electrodes. The design allows access to and control of gates whose total number exceeds that of the available electrical contacts and enables the formation, modulation and measurement of large arrays of quantum devices. We fabricate such devices on n-type GaAs/AlGaAs substrates and investigate the stability of the charge locked on to the gates. Proof-of-concept is shown by measurement of the Coulomb blockade peaks of a single quantum dot formed by a floating gate in the device. The floating gate is seen to drift by approximately one Coulomb oscillation per hour.

  18. MemFlash device: floating gate transistors as memristive devices for neuromorphic computing

    NASA Astrophysics Data System (ADS)

    Riggert, C.; Ziegler, M.; Schroeder, D.; Krautschneider, W. H.; Kohlstedt, H.

    2014-10-01

    Memristive devices are promising candidates for future non-volatile memory applications and mixed-signal circuits. In the field of neuromorphic engineering these devices are especially interesting to emulate neuronal functionality. Therefore, new materials and material combinations are currently investigated, which are often not compatible with Si-technology processes. The underlying mechanisms of the device often remain unclear and are paired with low device endurance and yield. These facts define the current most challenging development tasks towards a reliable memristive device technology. In this respect, the MemFlash concept is of particular interest. A MemFlash device results from a diode configuration wiring scheme of a floating gate transistor, which enables the persistent device resistance to be varied according to the history of the charge flow through the device. In this study, we investigate the scaling conditions of the floating gate oxide thickness with respect to possible applications in the field of neuromorphic engineering. We show that MemFlash cells exhibit essential features with respect to neuromorphic applications. In particular, cells with thin floating gate oxides show a limited synaptic weight growth together with low energy dissipation. MemFlash cells present an attractive alternative for state-of-art memresitive devices. The emulation of associative learning is discussed by implementing a single MemFlash cell in an analogue circuit.

  19. Using a Floating-Gate MOS Transistor as a Transducer in a MEMS Gas Sensing System

    PubMed Central

    Barranca, Mario Alfredo Reyes; Mendoza-Acevedo, Salvador; Flores-Nava, Luis M.; Avila-García, Alejandro; Vazquez-Acosta, E. N.; Moreno-Cadenas, José Antonio; Casados-Cruz, Gaspar

    2010-01-01

    Floating-gate MOS transistors have been widely used in diverse analog and digital applications. One of these is as a charge sensitive device in sensors for pH measurement in solutions or using gates with metals like Pd or Pt for hydrogen sensing. Efforts are being made to monolithically integrate sensors together with controlling and signal processing electronics using standard technologies. This can be achieved with the demonstrated compatibility between available CMOS technology and MEMS technology. In this paper an in-depth analysis is done regarding the reliability of floating-gate MOS transistors when charge produced by a chemical reaction between metallic oxide thin films with either reducing or oxidizing gases is present. These chemical reactions need temperatures around 200 °C or higher to take place, so thermal insulation of the sensing area must be assured for appropriate operation of the electronics at room temperature. The operation principle of the proposal here presented is confirmed by connecting the gate of a conventional MOS transistor in series with a Fe2O3 layer. It is shown that an electrochemical potential is present on the ferrite layer when reacting with propane. PMID:22163478

  20. Nanocrystal floating gate memory with solution-processed indium-zinc-tin-oxide channel and colloidal silver nanocrystals

    NASA Astrophysics Data System (ADS)

    Hu, Quanli; Ha, Sang-Hyub; Lee, Hyun Ho; Yoon, Tae-Sik

    2011-12-01

    A nanocrystal (NC) floating gate memory with solution-processed indium-zinc-tin-oxide (IZTO) channel and silver (Ag) NCs embedded in thin gate dielectric layer (SiO2(30 nm)/Al2O3(3 nm)) was fabricated. Both the IZTO channel and colloidal Ag NC layers were prepared by spin-coating and subsequent annealing, and dip-coating process, respectively. A threshold voltage shift up to ~0.9 V, corresponding to the electron density of 6.5 × 1011 cm-2, at gate pulsing <=10 V was achieved by the charging of high density NCs. These results present the successful non-volatile memory characteristics of an oxide-semiconductor transistor fabricated through solution processes.

  1. Design of a reversible single precision floating point subtractor.

    PubMed

    Anantha Lakshmi, Av; Sudha, Gf

    2014-01-04

    In recent years, Reversible logic has emerged as a major area of research due to its ability to reduce the power dissipation which is the main requirement in the low power digital circuit design. It has wide applications like low power CMOS design, Nano-technology, Digital signal processing, Communication, DNA computing and Optical computing. Floating-point operations are needed very frequently in nearly all computing disciplines, and studies have shown floating-point addition/subtraction to be the most used floating-point operation. However, few designs exist on efficient reversible BCD subtractors but no work on reversible floating point subtractor. In this paper, it is proposed to present an efficient reversible single precision floating-point subtractor. The proposed design requires reversible designs of an 8-bit and a 24-bit comparator unit, an 8-bit and a 24-bit subtractor, and a normalization unit. For normalization, a 24-bit Reversible Leading Zero Detector and a 24-bit reversible shift register is implemented to shift the mantissas. To realize a reversible 1-bit comparator, in this paper, two new 3x3 reversible gates are proposed The proposed reversible 1-bit comparator is better and optimized in terms of the number of reversible gates used, the number of transistor count and the number of garbage outputs. The proposed work is analysed in terms of number of reversible gates, garbage outputs, constant inputs and quantum costs. Using these modules, an efficient design of a reversible single precision floating point subtractor is proposed. Proposed circuits have been simulated using Modelsim and synthesized using Xilinx Virtex5vlx30tff665-3. The total on-chip power consumed by the proposed 32-bit reversible floating point subtractor is 0.410 W.

  2. Energy-band engineering for tunable memory characteristics through controlled doping of reduced graphene oxide.

    PubMed

    Han, Su-Ting; Zhou, Ye; Yang, Qing Dan; Zhou, Li; Huang, Long-Biao; Yan, Yan; Lee, Chun-Sing; Roy, Vellaisamy A L

    2014-02-25

    Tunable memory characteristics are used in multioperational mode circuits where memory cells with various functionalities are needed in one combined device. It is always a challenge to obtain control over threshold voltage for multimode operation. On this regard, we use a strategy of shifting the work function of reduced graphene oxide (rGO) in a controlled manner through doping gold chloride (AuCl3) and obtained a gradient increase of rGO work function. By inserting doped rGO as floating gate, a controlled threshold voltage (Vth) shift has been achieved in both p- and n-type low voltage flexible memory devices with large memory window (up to 4 times for p-type and 8 times for n-type memory devices) in comparison with pristine rGO floating gate memory devices. By proper energy band engineering, we demonstrated a flexible floating gate memory device with larger memory window and controlled threshold voltage shifts.

  3. Floating-Gate Manipulated Graphene-Black Phosphorus Heterojunction for Nonvolatile Ambipolar Schottky Junction Memories, Memory Inverter Circuits, and Logic Rectifiers.

    PubMed

    Li, Dong; Chen, Mingyuan; Zong, Qijun; Zhang, Zengxing

    2017-10-11

    The Schottky junction is an important unit in electronics and optoelectronics. However, its properties greatly degrade with device miniaturization. The fast development of circuits has fueled a rapid growth in the study of two-dimensional (2D) crystals, which may lead to breakthroughs in the semiconductor industry. Here we report a floating-gate manipulated nonvolatile ambipolar Schottky junction memory from stacked all-2D layers of graphene-BP/h-BN/graphene (BP, black phosphorus; h-BN, hexagonal boron nitride) in a designed floating-gate field-effect Schottky barrier transistor configuration. By manipulating the voltage pulse applied to the control gate, the device exhibits ambipolar characteristics and can be tuned to act as graphene-p-BP or graphene-n-BP junctions with reverse rectification behavior. Moreover, the junction exhibits good storability properties of more than 10 years and is also programmable. On the basis of these characteristics, we further demonstrate the application of the device to dual-mode nonvolatile Schottky junction memories, memory inverter circuits, and logic rectifiers.

  4. Disturb-Free Three-Dimensional Vertical Floating Gate NAND with Separated-Sidewall Control Gate

    NASA Astrophysics Data System (ADS)

    Seo, Moon-Sik; Endoh, Tetsuo

    2012-02-01

    Recently, the three-dimensional (3D) vertical floating gate (FG) type NAND cell arrays with the sidewall control gate (SCG) structure are receiving attention to overcome the reliability issues of charge trap (CT) type 3D NAND. In order to achieve the multilevel cell (MLC) operation for lower bit cost in 3D NAND, it is important to eliminate reliability issues, such as the Vth distribution with interference and disturbance problems and Vth shift with retention issues. In this paper, we intensively investigated the disturbance problems of the 3D vertical FG type NAND cell with separated-sidewall control gate (S-SCG) structure for the reliable MLC operation. Above all, we successfully demonstrate the fully suppressed disturbance problems, such as indirect programming of the unselected cells, hot electron injection of the edge cells and direct influence to the neighboring passing cells, by using the S-SCG with 30 nm pillar size.

  5. FLOAT OPERATED RADIAL GATE INSTALLATION. WASTEWAY NO. 1. WELLTONMOHAWK CANAL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FLOAT OPERATED RADIAL GATE INSTALLATION. WASTEWAY NO. 1. WELLTON-MOHAWK CANAL - STA. 99+23.50. United States Department of the Interior, Bureau of Reclamation; Gila Project, Arizona, Wellton-Mohawk Division. Drawing No. 50-D-2497, dated March 8, 1949, Denver Colorado. Sheet 1 of 7 - Wellton-Mohawk Irrigation System, Wasteway No. 1, Wellton-Mohawk Canal, North side of Wellton-Mohawk Canal, bounded by Gila River to North & the Union Pacific Railroad & Gila Mountains to south, Wellton, Yuma County, AZ

  6. FLOAT OPERATED RADIAL GATE HOIST ASSEMBLY LIST OF PARTS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    FLOAT OPERATED RADIAL GATE HOIST ASSEMBLY - LIST OF PARTS - BASE-CRANK. WASTEWAY NO. 1. WELLTON-MOHAWK CANAL - STA. 99+23.50. United States Department of the Interior, Bureau of Reclamation; Gila Project, Arizona, Wellton-Mohawk Division. Drawing No. 50-D-2511, dated May 3, 1949, Denver Colorado. Sheet 1 of 2 - Wellton-Mohawk Irrigation System, Wasteway No. 1, Wellton-Mohawk Canal, North side of Wellton-Mohawk Canal, bounded by Gila River to North & the Union Pacific Railroad & Gila Mountains to south, Wellton, Yuma County, AZ

  7. Two-dimensional molybdenum disulphide nanosheet-covered metal nanoparticle array as a floating gate in multi-functional flash memories

    NASA Astrophysics Data System (ADS)

    Han, Su-Ting; Zhou, Ye; Chen, Bo; Zhou, Li; Yan, Yan; Zhang, Hua; Roy, V. A. L.

    2015-10-01

    Semiconducting two-dimensional materials appear to be excellent candidates for non-volatile memory applications. However, the limited controllability of charge trapping behaviors and the lack of multi-bit storage studies in two-dimensional based memory devices require further improvement for realistic applications. Here, we report a flash memory consisting of metal NPs-molybdenum disulphide (MoS2) as a floating gate by introducing a metal nanoparticle (NP) (Ag, Au, Pt) monolayer underneath the MoS2 nanosheets. Controlled charge trapping and long data retention have been achieved in a metal (Ag, Au, Pt) NPs-MoS2 floating gate flash memory. This controlled charge trapping is hypothesized to be attributed to band bending and a built-in electric field ξbi between the interface of the metal NPs and MoS2. The metal NPs-MoS2 floating gate flash memories were further proven to be multi-bit memory storage devices possessing a 3-bit storage capability and a good retention capability up to 104 s. We anticipate that these findings would provide scientific insight for the development of novel memory devices utilizing an atomically thin two-dimensional lattice structure.Semiconducting two-dimensional materials appear to be excellent candidates for non-volatile memory applications. However, the limited controllability of charge trapping behaviors and the lack of multi-bit storage studies in two-dimensional based memory devices require further improvement for realistic applications. Here, we report a flash memory consisting of metal NPs-molybdenum disulphide (MoS2) as a floating gate by introducing a metal nanoparticle (NP) (Ag, Au, Pt) monolayer underneath the MoS2 nanosheets. Controlled charge trapping and long data retention have been achieved in a metal (Ag, Au, Pt) NPs-MoS2 floating gate flash memory. This controlled charge trapping is hypothesized to be attributed to band bending and a built-in electric field ξbi between the interface of the metal NPs and MoS2. The metal NPs-MoS2 floating gate flash memories were further proven to be multi-bit memory storage devices possessing a 3-bit storage capability and a good retention capability up to 104 s. We anticipate that these findings would provide scientific insight for the development of novel memory devices utilizing an atomically thin two-dimensional lattice structure. Electronic supplementary information (ESI) available: Energy-dispersive X-ray spectroscopy (EDS) spectra of the metal NPs, SEM image of MoS2 on Au NPs, erasing operations of the metal NPs-MoS2 memory device, transfer characteristics of the standard FET devices and Ag NP devices under programming operation, tapping-mode AFM height image of the fabricated MoS2 film for pristine MoS2 flash memory, gate signals used for programming the Au NPs-MoS2 and Pt NPs-MoS2 flash memories, and data levels recorded for 100 sequential cycles. See DOI: 10.1039/c5nr05054e

  8. Highly reliable top-gated thin-film transistor memory with semiconducting, tunneling, charge-trapping, and blocking layers all of flexible polymers.

    PubMed

    Wang, Wei; Hwang, Sun Kak; Kim, Kang Lib; Lee, Ju Han; Cho, Suk Man; Park, Cheolmin

    2015-05-27

    The core components of a floating-gate organic thin-film transistor nonvolatile memory (OTFT-NVM) include the semiconducting channel layer, tunneling layer, floating-gate layer, and blocking layer, besides three terminal electrodes. In this study, we demonstrated OTFT-NVMs with all four constituent layers made of polymers based on consecutive spin-coating. Ambipolar charges injected and trapped in a polymer electret charge-controlling layer upon gate program and erase field successfully allowed for reliable bistable channel current levels at zero gate voltage. We have observed that the memory performance, in particular the reliability of a device, significantly depends upon the thickness of both blocking and tunneling layers, and with an optimized layer thickness and materials selection, our device exhibits a memory window of 15.4 V, on/off current ratio of 2 × 10(4), read and write endurance cycles over 100, and time-dependent data retention of 10(8) s, even when fabricated on a mechanically flexible plastic substrate.

  9. Rewritable ghost floating gates by tunnelling triboelectrification for two-dimensional electronics

    PubMed Central

    Kim, Seongsu; Kim, Tae Yun; Lee, Kang Hyuck; Kim, Tae-Ho; Cimini, Francesco Arturo; Kim, Sung Kyun; Hinchet, Ronan; Kim, Sang-Woo; Falconi, Christian

    2017-01-01

    Gates can electrostatically control charges inside two-dimensional materials. However, integrating independent gates typically requires depositing and patterning suitable insulators and conductors. Moreover, after manufacturing, gates are unchangeable. Here we introduce tunnelling triboelectrification for localizing electric charges in very close proximity of two-dimensional materials. As representative materials, we use chemical vapour deposition graphene deposited on a SiO2/Si substrate. The triboelectric charges, generated by friction with a Pt-coated atomic force microscope tip and injected through defects, are trapped at the air–SiO2 interface underneath graphene and act as ghost floating gates. Tunnelling triboelectrification uniquely permits to create, modify and destroy p and n regions at will with the spatial resolution of atomic force microscopes. As a proof of concept, we draw rewritable p/n+ and p/p+ junctions with resolutions as small as 200 nm. Our results open the way to time-variant two-dimensional electronics where conductors, p and n regions can be defined on demand. PMID:28649986

  10. Rewritable ghost floating gates by tunnelling triboelectrification for two-dimensional electronics

    NASA Astrophysics Data System (ADS)

    Kim, Seongsu; Kim, Tae Yun; Lee, Kang Hyuck; Kim, Tae-Ho; Cimini, Francesco Arturo; Kim, Sung Kyun; Hinchet, Ronan; Kim, Sang-Woo; Falconi, Christian

    2017-06-01

    Gates can electrostatically control charges inside two-dimensional materials. However, integrating independent gates typically requires depositing and patterning suitable insulators and conductors. Moreover, after manufacturing, gates are unchangeable. Here we introduce tunnelling triboelectrification for localizing electric charges in very close proximity of two-dimensional materials. As representative materials, we use chemical vapour deposition graphene deposited on a SiO2/Si substrate. The triboelectric charges, generated by friction with a Pt-coated atomic force microscope tip and injected through defects, are trapped at the air-SiO2 interface underneath graphene and act as ghost floating gates. Tunnelling triboelectrification uniquely permits to create, modify and destroy p and n regions at will with the spatial resolution of atomic force microscopes. As a proof of concept, we draw rewritable p/n+ and p/p+ junctions with resolutions as small as 200 nm. Our results open the way to time-variant two-dimensional electronics where conductors, p and n regions can be defined on demand.

  11. X-band T/R switch with body-floating multi-gate PDSOI NMOS transistors

    NASA Astrophysics Data System (ADS)

    Park, Mingyo; Min, Byung-Wook

    2018-03-01

    This paper presents an X-band transmit/receive switch using multi-gate NMOS transistors in a silicon-on-insulator CMOS process. For low loss and high power handling capability, floating body multi-gate NMOS transistors are adopted instead of conventional stacked NMOS transistors, resulting in 53% reduction of transistor area. Comparing to the stacked NMOS transistors, the multi gate transistor shares the source and drain region between stacked transistors, resulting in reduced chip area and parasitics. The impedance between bodies of gates in multi-gate NMOS transistors is assumed to be very large during design and confirmed after measurement. The measured input 1 dB compression point is 34 dBm. The measured insertion losses of TX and RX modes are respectively 1.7 dB and 2.0 dB at 11 GHz, and the measured isolations of TX and RX modes are >27 dB and >20 dB in X-band, respectively. The chip size is 0.086 mm2 without pads, which is 25% smaller than the T/R switch with stacked transistors.

  12. Photoresponses in Gold Nanoparticle Single-Electron Transistors with Molecular Floating Gates

    NASA Astrophysics Data System (ADS)

    Noguchi, Yutaka; Yamamoto, Makoto; Ishii, Hisao; Ueda, Rieko; Terui, Toshifumi; Imazu, Keisuke; Tamada, Kaoru; Sakano, Takeshi; Matsuda, Kenji

    2013-11-01

    We have proposed a simple method of activating advanced functions in single-electron transistors (SETs) based on the specific properties of individual molecules. As a prototype, we fabricated a copper phthalocyanine (CuPc)-doped SET. The device consists of a gold-nanoparticle (GNP)-based SET doped with CuPc as a photoresponsive floating gate. In this paper, we report the details of the photoresponses of the CuPc-doped SET, such as conductance switching, sensitivity to the wavelength of the incident light, and multiple induced states.

  13. Upsets in Erased Floating Gate Cells With High-Energy Protons

    DOE PAGES

    Gerardin, S.; Bagatin, M.; Paccagnella, A.; ...

    2017-01-01

    We discuss upsets in erased floating gate cells, due to large threshold voltage shifts, using statistical distributions collected on a large number of memory cells. The spread in the neutral threshold voltage appears to be too low to quantitatively explain the experimental observations in terms of simple charge loss, at least in SLC devices. The possibility that memories exposed to high energy protons and heavy ions exhibit negative charge transfer between programmed and erased cells is investigated, although the analysis does not provide conclusive support to this hypothesis.

  14. The GaN trench gate MOSFET with floating islands: High breakdown voltage and improved BFOM

    NASA Astrophysics Data System (ADS)

    Shen, Lingyan; Müller, Stephan; Cheng, Xinhong; Zhang, Dongliang; Zheng, Li; Xu, Dawei; Yu, Yuehui; Meissner, Elke; Erlbacher, Tobias

    2018-02-01

    A novel GaN trench gate (TG) MOSFET with P-type floating islands (FLI) in drift region, which can suppress the electric field peak at bottom of gate trench during the blocking state and prevent premature breakdown in gate oxide, is proposed and investigated by TCAD simulations. The influence of thickness, position, doping concentration and length of the FLI on breakdown voltage (BV) and specific on-resistance (Ron_sp) is studied, providing useful guidelines for design of this new type of device. Using optimized parameters for the FLI, GaN FLI TG-MOSFET obtains a BV as high as 2464 V with a Ron_sp of 3.0 mΩ cm2. Compared to the conventional GaN TG-MOSFET with the same structure parameters, the Baliga figure of merit (BFOM) is enhanced by 150%, getting closer to theoretical limit for GaN devices.

  15. Floating-Point Units and Algorithms for field-programmable gate arrays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Underwood, Keith D.; Hemmert, K. Scott

    2005-11-01

    The software that we are attempting to copyright is a package of floating-point unit descriptions and example algorithm implementations using those units for use in FPGAs. The floating point units are best-in-class implementations of add, multiply, divide, and square root floating-point operations. The algorithm implementations are sample (not highly flexible) implementations of FFT, matrix multiply, matrix vector multiply, and dot product. Together, one could think of the collection as an implementation of parts of the BLAS library or something similar to the FFTW packages (without the flexibility) for FPGAs. Results from this work has been published multiple times and wemore » are working on a publication to discuss the techniques we use to implement the floating-point units, For some more background, FPGAS are programmable hardware. "Programs" for this hardware are typically created using a hardware description language (examples include Verilog, VHDL, and JHDL). Our floating-point unit descriptions are written in JHDL, which allows them to include placement constraints that make them highly optimized relative to some other implementations of floating-point units. Many vendors (Nallatech from the UK, SRC Computers in the US) have similar implementations, but our implementations seem to be somewhat higher performance. Our algorithm implementations are written in VHDL and models of the floating-point units are provided in VHDL as well. FPGA "programs" make multiple "calls" (hardware instantiations) to libraries of intellectual property (IP), such as the floating-point unit library described here. These programs are then compiled using a tool called a synthesizer (such as a tool from Synplicity, Inc.). The compiled file is a netlist of gates and flip-flops. This netlist is then mapped to a particular type of FPGA by a mapper and then a place- and-route tool. These tools assign the gates in the netlist to specific locations on the specific type of FPGA chip used and constructs the required routes between them. The result is a "bitstream" that is analogous to a compiled binary. The bitstream is loaded into the FPGA to create a specific hardware configuration.« less

  16. Modeling and simulation of floating gate nanocrystal FET devices and circuits

    NASA Astrophysics Data System (ADS)

    Hasaneen, El-Sayed A. M.

    The nonvolatile memory market has been growing very fast during the last decade, especially for mobile communication systems. The Semiconductor Industry Association International Technology Roadmap for Semiconductors states that the difficult challenge for nonvolatile semiconductor memories is to achieve reliable, low power, low voltage performance and high-speed write/erase. This can be achieved by aggressive scaling of the nonvolatile memory cells. Unfortunately, scaling down of conventional nonvolatile memory will further degrade the retention time due to the charge loss between the floating gate and drain/source contacts and substrate which makes conventional nonvolatile memory unattractive. Using nanocrystals as charge storage sites reduces dramatically the charge leakage through oxide defects and drain/source contacts. Floating gate nanocrystal nonvolatile memory, FG-NCNVM, is a candidate for future memory because it is advantageous in terms of high-speed write/erase, small size, good scalability, low-voltage, low-power applications, and the capability to store multiple bits per cell. Many studies regarding FG-NCNVMs have been published. Most of them have dealt with fabrication improvements of the devices and device characterizations. Due to the promising FG-NCNVM applications in integrated circuits, there is a need for circuit a simulation model to simulate the electrical characteristics of the floating gate devices. In this thesis, a FG-NCNVM circuit simulation model has been proposed. It is based on the SPICE BSIM simulation model. This model simulates the cell behavior during normal operation. Model validation results have been presented. The SPICE model shows good agreement with experimental results. Current-voltage characteristics, transconductance and unity gain frequency (fT) have been studied showing the effect of the threshold voltage shift (DeltaVth) due to nanocrystal charge on the device characteristics. The threshold voltage shift due to nanocrystal charge has a strong effect on the memory characteristics. Also, the programming operation of the memory cell has been investigated. The tunneling rate from quantum well channel to quantum dot (nanocrystal) gate is calculated. The calculations include various memory parameters, wavefunctions, and energies of quantum well channel and quantum dot gate. The use of floating gate nanocrystal memory as a transistor with a programmable threshold voltage has been demonstrated. The incorporation of FG-NCFETs to design programmable integrated circuit building blocks has been discussed. This includes the design of programmable current and voltage reference circuits. Finally, we demonstrated the design of tunable gain op-amp incorporating FG-NCFETs. Programmable integrated circuit building blocks can be used in intelligent analog and digital systems.

  17. Numerical model of a single nanocrystal devoted to the study of disordered nanocrystal floating gates of new flash memories

    NASA Astrophysics Data System (ADS)

    Leroy, Yann; Armeanu, Dumitru; Cordan, Anne-Sophie

    2011-05-01

    The improvement of our model concerning a single nanocrystal that belongs to a nanocrystal floating gate of a flash memory is presented. In order to extend the gate voltage range applicability of the model, the 3D continuum of states of either metallic or semiconducting electrodes is discretized into 2D subbands. Such an approach gives precise information about the mechanisms behind the charging or release processes of the nanocrystal. Then, the self-energy and screening effects of an electron within the nanocrystal are evaluated and introduced in the model. This enables a better determination of the operating point of the nanocrystal memory. The impact of those improvements on the charging or release time of the nanocrystal is discussed.

  18. Theory of the synchronous motion of an array of floating flap gates oscillating wave surge converter

    NASA Astrophysics Data System (ADS)

    Michele, Simone; Sammarco, Paolo; d'Errico, Michele

    2016-08-01

    We consider a finite array of floating flap gates oscillating wave surge converter (OWSC) in water of constant depth. The diffraction and radiation potentials are solved in terms of elliptical coordinates and Mathieu functions. Generated power and capture width ratio of a single gate excited by incoming waves are given in terms of the radiated wave amplitude in the far field. Similar to the case of axially symmetric absorbers, the maximum power extracted is shown to be directly proportional to the incident wave characteristics: energy flux, angle of incidence and wavelength. Accordingly, the capture width ratio is directly proportional to the wavelength, thus giving a design estimate of the maximum efficiency of the system. We then compare the array and the single gate in terms of energy production. For regular waves, we show that excitation of the out-of-phase natural modes of the array increases the power output, while in the case of random seas we show that the array and the single gate achieve the same efficiency.

  19. Oleyl group-functionalized insulating gate transistors for measuring extracellular pH of floating cells

    NASA Astrophysics Data System (ADS)

    Imaizumi, Yuki; Goda, Tatsuro; Toya, Yutaro; Matsumoto, Akira; Miyahara, Yuji

    2016-01-01

    The extracellular ionic microenvironment has a close relationship to biological activities such as by cellular respiration, cancer development, and immune response. A system composed of ion-sensitive field-effect transistors (ISFET), cells, and program-controlled fluidics has enabled the acquisition of real-time information about the integrity of the cell membrane via pH measurement. Here we aimed to extend this system toward floating cells such as T lymphocytes for investigating complement activation and pharmacokinetics through alternations in the plasma membrane integrity. We functionalized the surface of tantalum oxide gate insulator of ISFET with oleyl-tethered phosphonic acid for interacting with the plasma membranes of floating cells without affecting the cell signaling. The surface modification was characterized by X-ray photoelectron spectroscopy and water contact angle measurements. The Nernst response of -37.8 mV/pH was obtained for the surface-modified ISFET at 37 °C. The oleyl group-functionalized gate insulator successfully captured Jurkat T cells in a fluidic condition without acute cytotoxicity. The system was able to record the time course of pH changes at the cells/ISFET interface during the process of instant addition and withdrawal of ammonium chloride. Further, the plasma membrane injury of floating cells after exposure by detergent Triton™ X-100 was successfully determined using the modified ISFET with enhanced sensitivity as compared with conventional hemolysis assays.

  20. Oleyl group-functionalized insulating gate transistors for measuring extracellular pH of floating cells

    PubMed Central

    Imaizumi, Yuki; Goda, Tatsuro; Toya, Yutaro; Matsumoto, Akira; Miyahara, Yuji

    2016-01-01

    Abstract The extracellular ionic microenvironment has a close relationship to biological activities such as by cellular respiration, cancer development, and immune response. A system composed of ion-sensitive field-effect transistors (ISFET), cells, and program-controlled fluidics has enabled the acquisition of real-time information about the integrity of the cell membrane via pH measurement. Here we aimed to extend this system toward floating cells such as T lymphocytes for investigating complement activation and pharmacokinetics through alternations in the plasma membrane integrity. We functionalized the surface of tantalum oxide gate insulator of ISFET with oleyl-tethered phosphonic acid for interacting with the plasma membranes of floating cells without affecting the cell signaling. The surface modification was characterized by X-ray photoelectron spectroscopy and water contact angle measurements. The Nernst response of −37.8 mV/pH was obtained for the surface-modified ISFET at 37 °C. The oleyl group-functionalized gate insulator successfully captured Jurkat T cells in a fluidic condition without acute cytotoxicity. The system was able to record the time course of pH changes at the cells/ISFET interface during the process of instant addition and withdrawal of ammonium chloride. Further, the plasma membrane injury of floating cells after exposure by detergent Triton™ X-100 was successfully determined using the modified ISFET with enhanced sensitivity as compared with conventional hemolysis assays. PMID:27877886

  1. Electrical overstress in AlGaN/GaN HEMTs: study of degradation processes

    NASA Astrophysics Data System (ADS)

    Kuzmík, J.; Pogany, D.; Gornik, E.; Javorka, P.; Kordoš, P.

    2004-02-01

    We study degradation mechanisms in 50 μm gate width/0.45 μm length AlGaN/GaN HEMTs after electrical overstresses. One hundred nanosecond long rectangular current pulses are applied on the drain contact keeping either both of the source and gate grounded or the source grounded and gate floating. Source-drain pulsed I- V characteristics show similar shape for both connections. After the HEMT undergoes the source-drain breakdown, a negative differential resistance region transits into a low voltage/high current region. Changes in the Schottky contact dc I- V characteristics and in the source and drain ohmic contacts are investigated as a function of the current stress level and are related to the HEMT dc performance. Catastrophic HEMT degradation was observed after Istress=1.65 A in case of the 'gate floating' connection due to ohmic contacts burnout. In case of the 'gate grounded' connection, Istress=0.45 A was sufficient for the gate failure showing a high gate susceptibility to overstress. Backside transient interferometric mapping technique experiment reveals a current filament formation under both HEMT stress connections. Infrared camera observations lead to conclusion that the filament formation together with a consequent high-density electron flow is responsible for a dark spot formation and gradual ohmic contact degradation.

  2. Leaky Integrate and Fire Neuron by Charge-Discharge Dynamics in Floating-Body MOSFET.

    PubMed

    Dutta, Sangya; Kumar, Vinay; Shukla, Aditya; Mohapatra, Nihar R; Ganguly, Udayan

    2017-08-15

    Neuro-biology inspired Spiking Neural Network (SNN) enables efficient learning and recognition tasks. To achieve a large scale network akin to biology, a power and area efficient electronic neuron is essential. Earlier, we had demonstrated an LIF neuron by a novel 4-terminal impact ionization based n+/p/n+ with an extended gate (gated-INPN) device by physics simulation. Excellent improvement in area and power compared to conventional analog circuit implementations was observed. In this paper, we propose and experimentally demonstrate a compact conventional 3-terminal partially depleted (PD) SOI- MOSFET (100 nm gate length) to replace the 4-terminal gated-INPN device. Impact ionization (II) induced floating body effect in SOI-MOSFET is used to capture LIF neuron behavior to demonstrate spiking frequency dependence on input. MHz operation enables attractive hardware acceleration compared to biology. Overall, conventional PD-SOI-CMOS technology enables very-large-scale-integration (VLSI) which is essential for biology scale (~10 11 neuron based) large neural networks.

  3. 1T Pixel Using Floating-Body MOSFET for CMOS Image Sensors.

    PubMed

    Lu, Guo-Neng; Tournier, Arnaud; Roy, François; Deschamps, Benoît

    2009-01-01

    We present a single-transistor pixel for CMOS image sensors (CIS). It is a floating-body MOSFET structure, which is used as photo-sensing device and source-follower transistor, and can be controlled to store and evacuate charges. Our investigation into this 1T pixel structure includes modeling to obtain analytical description of conversion gain. Model validation has been done by comparing theoretical predictions and experimental results. On the other hand, the 1T pixel structure has been implemented in different configurations, including rectangular-gate and ring-gate designs, and variations of oxidation parameters for the fabrication process. The pixel characteristics are presented and discussed.

  4. A sub-microwatt piezo-floating-gate sensor for long-term fatigue monitoring in biomechanical implants.

    PubMed

    Lajnef, Nizar; Chakrabartty, Shantanu; Elvin, Niell; Elvin, Alex

    2006-01-01

    In this paper we describe an implementation of a novel fatigue monitoring sensor based on integration of piezoelectric transduction with floating gate avalanche injection. The miniaturized sensor enables continuous battery-less monitoring and time-to-failure predictions of biomechanical implants. Measured results from a fabricated prototype in a 0.5 microm CMOS process indicate that the device can compute cumulative statistics of electrical signals generated by piezoelectric transducer, while consuming less that 1 microW of power. The ultra-low power operation makes the sensor attractive for integration with poly-vinylidene difluoride (PVDF) based transducers that have already proven to be biocompatible.

  5. Thermal Stress Analysis of Floating-Gate Tunneling Oxide Electrically Erasable Programmable Read Only Memory During Manufacturing Process

    NASA Astrophysics Data System (ADS)

    Zong, Xiang-fu; Wang, Xu; Weng, Yu-min; Yan, Ren-jin; Tang, Guo-an; Zhang, Zhao-qiang

    1998-10-01

    In this study, finite element modeling was used to evaluate the residual thermal stress in floating-gate tunneling oxide electrically erasable programmable read only memory (FLOTOX E2 PROMs) manufacturing process. Special attention is paid to the tunnel oxide region, in which high field electron injection is the basis to E2 PROMs operation. Calculated results show the presence of large stresses and stress gradients at the fringe. This may contribute to the invalidation of E2 PROMs. A possible failure mechanism of E2 PROM related to residual thermal stress-induced leakage is proposed.

  6. Endurance degradation and lifetime model of p-channel floating gate flash memory device with 2T structure

    NASA Astrophysics Data System (ADS)

    Wei, Jiaxing; Liu, Siyang; Liu, Xiaoqiang; Sun, Weifeng; Liu, Yuwei; Liu, Xiaohong; Hou, Bo

    2017-08-01

    The endurance degradation mechanisms of p-channel floating gate flash memory device with two-transistor (2T) structure are investigated in detail in this work. With the help of charge pumping (CP) measurements and Sentaurus TCAD simulations, the damages in the drain overlap region along the tunnel oxide interface caused by band-to-band (BTB) tunneling programming and the damages in the channel region resulted from Fowler-Nordheim (FN) tunneling erasure are verified respectively. Furthermore, the lifetime model of endurance characteristic is extracted, which can extrapolate the endurance degradation tendency and predict the lifetime of the device.

  7. A Radiation-Tolerant, Low-Power Non-Volatile Memory Based on Silicon Nanocrystal Quantum Dots

    NASA Technical Reports Server (NTRS)

    Bell, L. D.; Boer, E. A.; Ostraat, M. L.; Brongersma, M. L.; Flagan, R. C.; Atwater, H. A.; deBlauwe, J.; Green, M. L.

    2001-01-01

    Nanocrystal nonvolatile floating-gate memories are a good candidate for space applications - initial results suggest they are fast, more reliable and consume less power than conventional floating gate memories. In the nanocrystal based NVM device, charge is not stored on a continuous polysilicon layer (so-called floating gate), but instead on a layer of discrete nanocrystals. Charge injection and storage in dense arrays of silicon nanocrystals in SiO2 is a critical aspect of the performance of potential nanocrystal flash memory structures. The ultimate goal for this class of devices is few- or single-electron storage in a small number of nanocrystal elements. In addition, the nanocrystal layer fabrication technique should be simple, 8-inch wafer compatible and well controlled in program/erase threshold voltage swing was seen during 100,000 program and erase cycles. Additional near-term goals for this project include extensive testing for radiation hardness and the development of artificial layered tunnel barrier heterostructures which have the potential for large speed enhancements for read/write of nanocrystal memory elements, compared with conventional flash devices. Additional information is contained in the original extended abstract.

  8. 76 FR 22882 - Draft National Pollutant Discharge Elimination System (NPDES) General Permit for Stormwater...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-25

    ... know your identity or contact information unless you provide it in the body of your comment. If you... include your name and other contact information in the body of your comment and with any disk or CD-ROM... visually assess the quality of the discharge (e.g., color, odor, floating, settled, or suspended solids) if...

  9. Low-voltage high-speed programming gate-all-around floating gate memory cell with tunnel barrier engineering

    NASA Astrophysics Data System (ADS)

    Hamzah, Afiq; Ezaila Alias, N.; Ismail, Razali

    2018-06-01

    The aim of this study is to investigate the memory performances of gate-all-around floating gate (GAA-FG) memory cell implementing engineered tunnel barrier concept of variable oxide thickness (VARIOT) of low-k/high-k for several high-k (i.e., Si3N4, Al2O3, HfO2, and ZrO2) with low-k SiO2 using three-dimensional (3D) simulator Silvaco ATLAS. The simulation work is conducted by initially determining the optimized thickness of low-k/high-k barrier-stacked and extracting their Fowler–Nordheim (FN) coefficients. Based on the optimized parameters the device performances of GAA-FG for fast program operation and data retention are assessed using benchmark set by 6 and 8 nm SiO2 tunnel layer respectively. The programming speed has been improved and wide memory window with 30% increment from conventional SiO2 has been obtained using SiO2/Al2O3 tunnel layer due to its thin low-k dielectric thickness. Furthermore, given its high band edges only 1% of charge-loss is expected after 10 years of ‑3.6/3.6 V gate stress.

  10. Stretchable carbon nanotube charge-trap floating-gate memory and logic devices for wearable electronics.

    PubMed

    Son, Donghee; Koo, Ja Hoon; Song, Jun-Kyul; Kim, Jaemin; Lee, Mincheol; Shim, Hyung Joon; Park, Minjoon; Lee, Minbaek; Kim, Ji Hoon; Kim, Dae-Hyeong

    2015-05-26

    Electronics for wearable applications require soft, flexible, and stretchable materials and designs to overcome the mechanical mismatch between the human body and devices. A key requirement for such wearable electronics is reliable operation with high performance and robustness during various deformations induced by motions. Here, we present materials and device design strategies for the core elements of wearable electronics, such as transistors, charge-trap floating-gate memory units, and various logic gates, with stretchable form factors. The use of semiconducting carbon nanotube networks designed for integration with charge traps and ultrathin dielectric layers meets the performance requirements as well as reliability, proven by detailed material and electrical characterizations using statistics. Serpentine interconnections and neutral mechanical plane layouts further enhance the deformability required for skin-based systems. Repetitive stretching tests and studies in mechanics corroborate the validity of the current approaches.

  11. Nonvolatile floating gate organic memory device based on pentacene/CdSe quantum dot heterojuction

    NASA Astrophysics Data System (ADS)

    Shin, Ik-Soo; Kim, Jung-Min; Jeun, Jun-Ho; Yoo, Seok-Hyun; Ge, Ziyi; Hong, Jong-In; Ho Bang, Jin; Kim, Yong-Sang

    2012-04-01

    An organic floating-gate memory device using CdSe quantum dots (QDs) as a charge-trapping element was fabricated. CdSe QDs were localized beneath a pentacene without any tunneling insulator, and the QD layer played a role as hole-trapping sites. The band bending formed at the junction between pentacene and QD layers inhibited back-injection of holes trapped in CdSe into pentacene, which appeared as a hysteretic capacitance-voltage response during the operation of the device. Nearly, 60% of trapped charge was sustained even after 104 s in programmed state, and this long retention time can be potentially useful in practical applications of non-volatile memory.

  12. Synergistic High Charge-Storage Capacity for Multi-level Flexible Organic Flash Memory

    NASA Astrophysics Data System (ADS)

    Kang, Minji; Khim, Dongyoon; Park, Won-Tae; Kim, Jihong; Kim, Juhwan; Noh, Yong-Young; Baeg, Kang-Jun; Kim, Dong-Yu

    2015-07-01

    Electret and organic floating-gate memories are next-generation flash storage mediums for printed organic complementary circuits. While each flash memory can be easily fabricated using solution processes on flexible plastic substrates, promising their potential for on-chip memory organization is limited by unreliable bit operation and high write loads. We here report that new architecture could improve the overall performance of organic memory, and especially meet high storage for multi-level operation. Our concept depends on synergistic effect of electrical characterization in combination with a polymer electret (poly(2-vinyl naphthalene) (PVN)) and metal nanoparticles (Copper). It is distinguished from mostly organic nano-floating-gate memories by using the electret dielectric instead of general tunneling dielectric for additional charge storage. The uniform stacking of organic layers including various dielectrics and poly(3-hexylthiophene) (P3HT) as an organic semiconductor, followed by thin-film coating using orthogonal solvents, greatly improve device precision despite easy and fast manufacture. Poly(vinylidene fluoride-trifluoroethylene) [P(VDF-TrFE)] as high-k blocking dielectric also allows reduction of programming voltage. The reported synergistic organic memory devices represent low power consumption, high cycle endurance, high thermal stability and suitable retention time, compared to electret and organic nano-floating-gate memory devices.

  13. Synergistic High Charge-Storage Capacity for Multi-level Flexible Organic Flash Memory.

    PubMed

    Kang, Minji; Khim, Dongyoon; Park, Won-Tae; Kim, Jihong; Kim, Juhwan; Noh, Yong-Young; Baeg, Kang-Jun; Kim, Dong-Yu

    2015-07-23

    Electret and organic floating-gate memories are next-generation flash storage mediums for printed organic complementary circuits. While each flash memory can be easily fabricated using solution processes on flexible plastic substrates, promising their potential for on-chip memory organization is limited by unreliable bit operation and high write loads. We here report that new architecture could improve the overall performance of organic memory, and especially meet high storage for multi-level operation. Our concept depends on synergistic effect of electrical characterization in combination with a polymer electret (poly(2-vinyl naphthalene) (PVN)) and metal nanoparticles (Copper). It is distinguished from mostly organic nano-floating-gate memories by using the electret dielectric instead of general tunneling dielectric for additional charge storage. The uniform stacking of organic layers including various dielectrics and poly(3-hexylthiophene) (P3HT) as an organic semiconductor, followed by thin-film coating using orthogonal solvents, greatly improve device precision despite easy and fast manufacture. Poly(vinylidene fluoride-trifluoroethylene) [P(VDF-TrFE)] as high-k blocking dielectric also allows reduction of programming voltage. The reported synergistic organic memory devices represent low power consumption, high cycle endurance, high thermal stability and suitable retention time, compared to electret and organic nano-floating-gate memory devices.

  14. Wasteway, intake side. The floatoperated radial gates are housed behind ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Wasteway, intake side. The float-operated radial gates are housed behind the concrete (below water level), view to the northwest - Wellton-Mohawk Irrigation System, Wasteway No. 1, Wellton-Mohawk Canal, North side of Wellton-Mohawk Canal, bounded by Gila River to North & the Union Pacific Railroad & Gila Mountains to south, Wellton, Yuma County, AZ

  15. Refrigerant directly cooled capacitors

    DOEpatents

    Hsu, John S [Oak Ridge, TN; Seiber, Larry E [Oak Ridge, TN; Marlino, Laura D [Oak Ridge, TN; Ayers, Curtis W [Kingston, TN

    2007-09-11

    The invention is a direct contact refrigerant cooling system using a refrigerant floating loop having a refrigerant and refrigeration devices. The cooling system has at least one hermetic container disposed in the refrigerant floating loop. The hermetic container has at least one electronic component selected from the group consisting of capacitors, power electronic switches and gating signal module. The refrigerant is in direct contact with the electronic component.

  16. The floating-gate non-volatile semiconductor memory--from invention to the digital age.

    PubMed

    Sze, S M

    2012-10-01

    In the past 45 years (from 1967 to 2012), the non-volatile semiconductor memory (NVSM) has emerged from a floating-gate concept to the prime technology driver of the largest industry in the world-the electronics industry. In this paper, we briefly review the historical development of NVSM and project its future trends to the year 2020. In addition, we consider NVSM's wide-range of applications from the digital cellular phone to tablet computer to digital television. As the device dimension is scaled down to the deca-nanometer regime, we expect that many innovations will be made to meet the scaling challenges, and NVSM-inspired technology will continue to enrich and improve our lives for decades to come.

  17. Fabrication of a Silicon Nanowire on a Bulk Substrate by Use of a Plasma Etching and Total Ionizing Dose Effects on a Gate-All-Around Field-Effect Transistor

    NASA Technical Reports Server (NTRS)

    Moon, Dong-Il; Han, Jin-Woo; Meyyappan, Meyya

    2016-01-01

    The gate all around transistor is investigated through experiment. The suspended silicon nanowire for the next generation is fabricated on bulk substrate by plasma etching method. The scallop pattern generated by Bosch process is utilized to form a floating silicon nanowire. By combining anisotropic and istropic silicon etch process, the shape of nanowire is accurately controlled. From the suspended nanowire, the gate all around transistor is demonstrated. As the silicon nanowire is fully surrounded by the gate, the device shows excellent electrostatic characteristics.

  18. Investigation of impact of post-metallization annealing on reliability of 65 nm NOR floating-gate flash memories

    NASA Astrophysics Data System (ADS)

    Chiu, Shengfen; Xu, Yue; Ji, Xiaoli; Yan, Feng

    2016-12-01

    This paper investigates the impact of post-metallization annealing (PMA) in pure nitrogen ambient on the reliability of 65 nm NOR-type floating-gate flash memory devices. The experimental results show that, with PMA process, the cycling performance of flash cells, especially for the erasing speed is obviously degraded compared to that without PMA. It is found that the bulk oxide traps and tunnel oxide/Si interface traps are significantly increased with PMA treatment. The water/moisture residues left in the interlayer dielectric layers diffuse to tunnel oxide during PMA process is considered to be responsible for these traps generation, which further enhances the degradation of erase performance. Skipping PMA treatment is proposed to suppress the water diffusion effect on erase performance degradation of flash cells.

  19. Fabrication of arrayed Si nanowire-based nano-floating gate memory devices on flexible plastics.

    PubMed

    Yoon, Changjoon; Jeon, Youngin; Yun, Junggwon; Kim, Sangsig

    2012-01-01

    Arrayed Si nanowire (NW)-based nano-floating gate memory (NFGM) devices with Pt nanoparticles (NPs) embedded in Al2O3 gate layers are successfully constructed on flexible plastics by top-down approaches. Ten arrayed Si NW-based NFGM devices are positioned on the first level. Cross-linked poly-4-vinylphenol (PVP) layers are spin-coated on them as isolation layers between the first and second level, and another ten devices are stacked on the cross-linked PVP isolation layers. The electrical characteristics of the representative Si NW-based NFGM devices on the first and second levels exhibit threshold voltage shifts, indicating the trapping and detrapping of electrons in their NPs nodes. They have an average threshold voltage shift of 2.5 V with good retention times of more than 5 x 10(4) s. Moreover, most of the devices successfully retain their electrical characteristics after about one thousand bending cycles. These well-arrayed and stacked Si NW-based NFGM devices demonstrate the potential of nanowire-based devices for large-scale integration.

  20. N-Channel field-effect transistors with floating gates for extracellular recordings.

    PubMed

    Meyburg, Sven; Goryll, Michael; Moers, Jürgen; Ingebrandt, Sven; Böcker-Meffert, Simone; Lüth, Hans; Offenhäusser, Andreas

    2006-01-15

    A field-effect transistor (FET) for recording extracellular signals from electrogenic cells is presented. The so-called floating gate architecture combines a complementary metal oxide semiconductor (CMOS)-type n-channel transistor with an independent sensing area. This concept allows the transistor and sensing area to be optimised separately. The devices are robust and can be reused several times. The noise level of the devices was smaller than of comparable non-metallised gate FETs. In addition to the usual drift of FET devices, we observed a long-term drift that has to be controlled for future long-term measurements. The device performance for extracellular signal recording was tested using embryonic rat cardiac myocytes cultured on fibronectin-coated chips. The extracellular cell signals were recorded before and after the addition of the cardioactive isoproterenol. The signal shapes of the measured action potentials were comparable to the non-metallised gate FETs previously used in similar experiments. The fabrication of the devices involved the process steps of standard CMOS that were necessary to create n-channel transistors. The implementation of a complete CMOS process would facilitate the integration of the logical circuits necessary for signal pre-processing on a chip, which is a prerequisite for a greater number of sensor spots in future layouts.

  1. Push the flash floating gate memories toward the future low energy application

    NASA Astrophysics Data System (ADS)

    Della Marca, V.; Just, G.; Regnier, A.; Ogier, J.-L.; Simola, R.; Niel, S.; Postel-Pellerin, J.; Lalande, F.; Masoero, L.; Molas, G.

    2013-01-01

    In this paper the energy consumption of flash floating gate cell, during a channel hot electron operation, is investigated. We characterize the device using different ramp and box pulses on control gate, to find the best solution to have low energy consumption and good cell performances. We use a new dynamic method to measure the drain current absorption in order to evaluate the impact of different bias conditions, and to study the cell behavior. The programming window and the energy consumption are considered as fundamental parameters. Using this dynamic technique, three zones of work are found; it is possible to optimize the drain voltage during the programming operation to minimize the energy consumption. Moreover, the cell's performances are improved using the CHISEL effect, with a reverse body bias. After the study concerning the programming pulses adjusting, we show the results obtained by increasing the channel doping dose parameter. Considering a channel hot electron programming operation, it is important to focus our attention on the bitline leakage consumption contribution. We measured it for the unselected bitline cells, and we show the effects of the lightly doped drain implantation energy on the leakage current. In this way the impact of gate induced drain leakage in band-to-band tunneling regime decreases, improving the cell's performances in a memory array.

  2. Low-voltage all-inorganic perovskite quantum dot transistor memory

    NASA Astrophysics Data System (ADS)

    Chen, Zhiliang; Zhang, Yating; Zhang, Heng; Yu, Yu; Song, Xiaoxian; Zhang, Haiting; Cao, Mingxuan; Che, Yongli; Jin, Lufan; Li, Yifan; Li, Qingyan; Dai, Haitao; Yang, Junbo; Yao, Jianquan

    2018-05-01

    An all-inorganic cesium lead halide quantum dot (QD) based Au nanoparticle (NP) floating-gate memory with a solution processed layer-by-layer method is demonstrated. Easy synthesis at room temperature and excellent stability make all-inorganic CsPbBr3 perovskite QDs suitable as a semiconductor layer in low voltage nonvolatile transistor memory. The bipolarity of QDs has both electrons and holes stored in the Au NP floating gate, resulting in bidirectional shifts of initial threshold voltage according to the applied programing and erasing pulses. Under low operation voltage (±5 V), the memory achieved a great memory window (˜2.4 V), long retention time (>105 s), and stable endurance properties after 200 cycles. So the proposed memory device based on CsPbBr3 perovskite QDs has a great potential in the flash memory market.

  3. 3-D Observation of dopant distribution at NAND flash memory floating gate using Atom probe tomography

    NASA Astrophysics Data System (ADS)

    Lee, Ji-hyun; Chae, Byeong-Kyu; Kim, Joong-Jeong; Lee, Sun Young; Park, Chan Gyung

    2015-01-01

    Dopant control becomes more difficult and critical as silicon devices become smaller. We observed the dopant distribution in a thermally annealed polysilicon gate using Transmission Electron Microscopy (TEM) and Atom probe tomography (APT). Phosphorus was doped at the silicon-nitride-diffusion-barrier-layer-covered polycrystalline silicon gate. Carbon also incorporated at the gate for the enhancement of operation uniformity. The impurity distribution was observed using atom probe tomography. The carbon atoms had segregated at grain boundaries and suppressed silicon grain growth. Phosphorus atoms, on the other hand, tended to pile-up at the interface. A 1-nm-thick diffusion barrier effectively blocked P atom out-diffusion. [Figure not available: see fulltext.

  4. MOSFET Power Controller

    NASA Technical Reports Server (NTRS)

    Mitchell, J.; Jones, K.

    1986-01-01

    High current and voltage controlled remotely. Remote Power Conroller includes two series-connected banks of parallel-connected MOSFET's to withstand high current and voltage. Voltage sharing between switch banks, low-impedance, gate-drive circuits used. Provided controlled range for turn on. Individually trimmable to insure simultaneous switching within few nanoseconds during both turn on and turn off. Control circuit for each switch bank and over-current trip circuit float independently and supplied power via transformer T1 from inverter. Control of floating stages by optocouplers.

  5. Event-driven charge-coupled device design and applications therefor

    NASA Technical Reports Server (NTRS)

    Doty, John P. (Inventor); Ricker, Jr., George R. (Inventor); Burke, Barry E. (Inventor); Prigozhin, Gregory Y. (Inventor)

    2005-01-01

    An event-driven X-ray CCD imager device uses a floating-gate amplifier or other non-destructive readout device to non-destructively sense a charge level in a charge packet associated with a pixel. The output of the floating-gate amplifier is used to identify each pixel that has a charge level above a predetermined threshold. If the charge level is above a predetermined threshold the charge in the triggering charge packet and in the charge packets from neighboring pixels need to be measured accurately. A charge delay register is included in the event-driven X-ray CCD imager device to enable recovery of the charge packets from neighboring pixels for accurate measurement. When a charge packet reaches the end of the charge delay register, control logic either dumps the charge packet, or steers the charge packet to a charge FIFO to preserve it if the charge packet is determined to be a packet that needs accurate measurement. A floating-diffusion amplifier or other low-noise output stage device, which converts charge level to a voltage level with high precision, provides final measurement of the charge packets. The voltage level is eventually digitized by a high linearity ADC.

  6. Wavelength dependence and multiple-induced states in photoresponses of copper phthalocyanine-doped gold nanoparticle single-electron device

    NASA Astrophysics Data System (ADS)

    Yamamoto, Makoto; Ueda, Rieko; Terui, Toshifumi; Imazu, Keisuke; Tamada, Kaoru; Sakano, Takeshi; Matsuda, Kenji; Ishii, Hisao; Noguchi, Yutaka

    2014-01-01

    We have proposed a gold nanoparticle (GNP)-based single-electron transistor (SET) doped with a dye molecule, where the molecule works as a photoresponsive floating gate. Here, we examined the source-drain current (I_{\\text{SD}}) at a constant drain voltage under light irradiation with various wavelengths ranging from 400 to 700 nm. Current change was enhanced at the wavelengths of 600 and 700 nm, corresponding to the optical absorption band of the doped molecule (copper phthalocyanine: CuPc). Moreover, several peaks appear in the histograms of I_{\\text{SD}} during light irradiation, indicating that multiple discrete states were induced in the device. The results suggest that the current change was initiated by the light absorption of CuPc and multiple CuPc molecules near the GNP working as a floating gate. Molecular doping can activate advanced device functions in GNP-based SETs.

  7. Suppressing the memory state of floating gate transistors with repeated femtosecond laser backside irradiations

    NASA Astrophysics Data System (ADS)

    Chambonneau, Maxime; Souiki-Figuigui, Sarra; Chiquet, Philippe; Della Marca, Vincenzo; Postel-Pellerin, Jérémy; Canet, Pierre; Portal, Jean-Michel; Grojo, David

    2017-04-01

    We demonstrate that infrared femtosecond laser pulses with intensity above the two-photon ionization threshold of crystalline silicon induce charge transport through the tunnel oxide in floating gate Metal-Oxide-Semiconductor transistor devices. With repeated irradiations of Flash memory cells, we show how the laser-produced free-electrons naturally redistribute on both sides of the tunnel oxide until the electric field of the transistor is suppressed. This ability enables us to determine in a nondestructive, rapid and contactless way the flat band and the neutral threshold voltages of the tested device. The physical mechanisms including nonlinear ionization, quantum tunneling of free-carriers, and flattening of the band diagram are discussed for interpreting the experiments. The possibility to control the carriers in memory transistors with ultrashort pulses holds promises for fast and remote device analyses (reliability, security, and defectivity) and for considerable developments in the growing field of ultrafast microelectronics.

  8. A fast and low-power microelectromechanical system-based non-volatile memory device

    PubMed Central

    Lee, Sang Wook; Park, Seung Joo; Campbell, Eleanor E. B.; Park, Yung Woo

    2011-01-01

    Several new generation memory devices have been developed to overcome the low performance of conventional silicon-based flash memory. In this study, we demonstrate a novel non-volatile memory design based on the electromechanical motion of a cantilever to provide fast charging and discharging of a floating-gate electrode. The operation is demonstrated by using an electromechanical metal cantilever to charge a floating gate that controls the charge transport through a carbon nanotube field-effect transistor. The set and reset currents are unchanged after more than 11 h constant operation. Over 500 repeated programming and erasing cycles were demonstrated under atmospheric conditions at room temperature without degradation. Multinary bit programming can be achieved by varying the voltage on the cantilever. The operation speed of the device is faster than a conventional flash memory and the power consumption is lower than other memory devices. PMID:21364559

  9. Models for Total-Dose Radiation Effects in Non-Volatile Memory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, Philip Montgomery; Wix, Steven D.

    The objective of this work is to develop models to predict radiation effects in non- volatile memory: flash memory and ferroelectric RAM. In flash memory experiments have found that the internal high-voltage generators (charge pumps) are the most sensitive to radiation damage. Models are presented for radiation effects in charge pumps that demonstrate the experimental results. Floating gate models are developed for the memory cell in two types of flash memory devices by Intel and Samsung. These models utilize Fowler-Nordheim tunneling and hot electron injection to charge and erase the floating gate. Erase times are calculated from the models andmore » compared with experimental results for different radiation doses. FRAM is less sensitive to radiation than flash memory, but measurements show that above 100 Krad FRAM suffers from a large increase in leakage current. A model for this effect is developed which compares closely with the measurements.« less

  10. A wearable multiplexed silicon nonvolatile memory array using nanocrystal charge confinement

    PubMed Central

    Kim, Jaemin; Son, Donghee; Lee, Mincheol; Song, Changyeong; Song, Jun-Kyul; Koo, Ja Hoon; Lee, Dong Jun; Shim, Hyung Joon; Kim, Ji Hoon; Lee, Minbaek; Hyeon, Taeghwan; Kim, Dae-Hyeong

    2016-01-01

    Strategies for efficient charge confinement in nanocrystal floating gates to realize high-performance memory devices have been investigated intensively. However, few studies have reported nanoscale experimental validations of charge confinement in closely packed uniform nanocrystals and related device performance characterization. Furthermore, the system-level integration of the resulting devices with wearable silicon electronics has not yet been realized. We introduce a wearable, fully multiplexed silicon nonvolatile memory array with nanocrystal floating gates. The nanocrystal monolayer is assembled over a large area using the Langmuir-Blodgett method. Efficient particle-level charge confinement is verified with the modified atomic force microscopy technique. Uniform nanocrystal charge traps evidently improve the memory window margin and retention performance. Furthermore, the multiplexing of memory devices in conjunction with the amplification of sensor signals based on ultrathin silicon nanomembrane circuits in stretchable layouts enables wearable healthcare applications such as long-term data storage of monitored heart rates. PMID:26763827

  11. Study of the enhancement-mode AlGaN/GaN high electron mobility transistor with split floating gates

    NASA Astrophysics Data System (ADS)

    Wang, Hui; Wang, Ning; Jiang, Ling-Li; Zhao, Hai-Yue; Lin, Xin-Peng; Yu, Hong-Yu

    2017-11-01

    In this work, the charge storage based split floating gates (FGs) enhancement mode (E-mode) AlGaN/GaN high electron mobility transistors (HEMTs) are studied. The simulation results reveal that under certain density of two dimensional electron gas, the variation tendency of the threshold voltage (Vth) with the variation of the blocking dielectric thickness depends on the FG charge density. It is found that when the length sum and isolating spacing sum of the FGs both remain unchanged, the Vth shall decrease with the increasing FGs number but maintaining the device as E-mode. It is also reported that for the FGs HEMT, the failure of a FG will lead to the decrease of Vth as well as the increase of drain current, and the failure probability can be improved significantly with the increase of FGs number.

  12. A wearable multiplexed silicon nonvolatile memory array using nanocrystal charge confinement.

    PubMed

    Kim, Jaemin; Son, Donghee; Lee, Mincheol; Song, Changyeong; Song, Jun-Kyul; Koo, Ja Hoon; Lee, Dong Jun; Shim, Hyung Joon; Kim, Ji Hoon; Lee, Minbaek; Hyeon, Taeghwan; Kim, Dae-Hyeong

    2016-01-01

    Strategies for efficient charge confinement in nanocrystal floating gates to realize high-performance memory devices have been investigated intensively. However, few studies have reported nanoscale experimental validations of charge confinement in closely packed uniform nanocrystals and related device performance characterization. Furthermore, the system-level integration of the resulting devices with wearable silicon electronics has not yet been realized. We introduce a wearable, fully multiplexed silicon nonvolatile memory array with nanocrystal floating gates. The nanocrystal monolayer is assembled over a large area using the Langmuir-Blodgett method. Efficient particle-level charge confinement is verified with the modified atomic force microscopy technique. Uniform nanocrystal charge traps evidently improve the memory window margin and retention performance. Furthermore, the multiplexing of memory devices in conjunction with the amplification of sensor signals based on ultrathin silicon nanomembrane circuits in stretchable layouts enables wearable healthcare applications such as long-term data storage of monitored heart rates.

  13. Reduced distribution of threshold voltage shift in double layer NiSi2 nanocrystals for nano-floating gate memory applications.

    PubMed

    Choi, Sungjin; Lee, Junhyuk; Kim, Donghyoun; Oh, Seulki; Song, Wangyu; Choi, Seonjun; Choi, Eunsuk; Lee, Seung-Beck

    2011-12-01

    We report on the fabrication and capacitance-voltage characteristics of double layer nickel-silicide nanocrystals with Si3N4 interlayer tunnel barrier for nano-floating gate memory applications. Compared with devices using SiO2 interlayer, the use of Si3N4 interlayer separation reduced the average size (4 nm) and distribution (+/- 2.5 nm) of NiSi2 nanocrystal (NC) charge traps by more than 50% and giving a two fold increase in NC density to 2.3 x 10(12) cm(-2). The increased density and reduced NC size distribution resulted in a significantly decrease in the distribution of the device C-V characteristics. For each program voltage, the distribution of the shift in the threshold voltage was reduced by more than 50% on average to less than 0.7 V demonstrating possible multi-level-cell operation.

  14. Optimization of pentacene double floating gate memories based on charge injection regulated by SAM functionalization

    NASA Astrophysics Data System (ADS)

    Li, S.; Guérin, D.; Lenfant, S.; Lmimouni, K.

    2018-02-01

    Pentacene based double nano-floating gate memories (NFGM) by using gold nanoparticles (Au NPs) and reduced graphene oxide (rGO) sheets as charge trapping layers are prepared and demonstrated. Particularly, the NFGM chemically treated by 2,3,4,5,6-pentafluorobenzenethiol (PFBT) self-assembled monolayers (SAM) exhibits excellent memory performances, including high mobility of 0.23 cm2V-1s-1, the large memory window of 51 V, and the stable retention property more than 108 s. Comparing the performances of NFGM without treating with PFBT SAM, the improving performances of the memory devices by SAM modification are explained by the increase of charge injection, which could be further investigated by XPS and UPS. In particular, the results highlight the utility of SAM modulations and controlling of charge transport in the development of organic transistor memories.

  15. Quantitative Analysis of Charge Injection and Discharging of Si Nanocrystals and Arrays by Electrostatic Force Microscopy

    NASA Technical Reports Server (NTRS)

    Bell, L. D.; Boer, E.; Ostraat, M.; Brongersma, M. L.; Flagan, R. C.; Atwater, H. A.

    2000-01-01

    NASA requirements for computing and memory for microspacecraft emphasize high density, low power, small size, and radiation hardness. The distributed nature of storage elements in nanocrystal floating-gate memories leads to intrinsic fault tolerance and radiation hardness. Conventional floating-gate non-volatile memories are more susceptible to radiation damage. Nanocrystal-based memories also offer the possibility of faster, lower power operation. In the pursuit of filling these requirements, the following tasks have been accomplished: (1) Si nanocrystal charging has been accomplished with conducting-tip AFM; (2) Both individual nanocrystals on an oxide surface and nanocrystals formed by implantation have been charged; (3) Discharging is consistent with tunneling through a field-lowered oxide barrier; (4) Modeling of the response of the AFM to trapped charge has allowed estimation of the quantity of trapped charge; and (5) Initial attempts to fabricate competitive nanocrystal non-volatile memories have been extremely successful.

  16. Nanowire FET Based Neural Element for Robotic Tactile Sensing Skin

    PubMed Central

    Taube Navaraj, William; García Núñez, Carlos; Shakthivel, Dhayalan; Vinciguerra, Vincenzo; Labeau, Fabrice; Gregory, Duncan H.; Dahiya, Ravinder

    2017-01-01

    This paper presents novel Neural Nanowire Field Effect Transistors (υ-NWFETs) based hardware-implementable neural network (HNN) approach for tactile data processing in electronic skin (e-skin). The viability of Si nanowires (NWs) as the active material for υ-NWFETs in HNN is explored through modeling and demonstrated by fabricating the first device. Using υ-NWFETs to realize HNNs is an interesting approach as by printing NWs on large area flexible substrates it will be possible to develop a bendable tactile skin with distributed neural elements (for local data processing, as in biological skin) in the backplane. The modeling and simulation of υ-NWFET based devices show that the overlapping areas between individual gates and the floating gate determines the initial synaptic weights of the neural network - thus validating the working of υ-NWFETs as the building block for HNN. The simulation has been further extended to υ-NWFET based circuits and neuronal computation system and this has been validated by interfacing it with a transparent tactile skin prototype (comprising of 6 × 6 ITO based capacitive tactile sensors array) integrated on the palm of a 3D printed robotic hand. In this regard, a tactile data coding system is presented to detect touch gesture and the direction of touch. Following these simulation studies, a four-gated υ-NWFET is fabricated with Pt/Ti metal stack for gates, source and drain, Ni floating gate, and Al2O3 high-k dielectric layer. The current-voltage characteristics of fabricated υ-NWFET devices confirm the dependence of turn-off voltages on the (synaptic) weight of each gate. The presented υ-NWFET approach is promising for a neuro-robotic tactile sensory system with distributed computing as well as numerous futuristic applications such as prosthetics, and electroceuticals. PMID:28979183

  17. Experimental Study of Floating-Gate-Type Metal-Oxide-Semiconductor Capacitors with Nanosize Triangular Cross-Sectional Tunnel Areas for Low Operating Voltage Flash Memory Application

    NASA Astrophysics Data System (ADS)

    Liu, Yongxun; Guo, Ruofeng; Kamei, Takahiro; Matsukawa, Takashi; Endo, Kazuhiko; O'uchi, Shinichi; Tsukada, Junichi; Yamauchi, Hiromi; Ishikawa, Yuki; Hayashida, Tetsuro; Sakamoto, Kunihiro; Ogura, Atsushi; Masahara, Meishoku

    2012-06-01

    The floating-gate (FG)-type metal-oxide-semiconductor (MOS) capacitors with planar (planar-MOS) and three-dimensional (3D) nanosize triangular cross-sectional tunnel areas (3D-MOS) have successfully been fabricated by introducing rapid thermal oxidation (RTO) and postdeposition annealing (PDA), and their electrical characteristics between the control gate (CG) and FG have been systematically compared. It was experimentally found in both planar- and 3D-MOS capacitors that the uniform and higher breakdown voltages are obtained by introducing RTO owing to the high-quality thermal oxide formation on the surface and etched edge regions of the n+ polycrystalline silicon (poly-Si) FG, and the leakage current is highly suppressed after PDA owing to the improved quality of the tetraethylorthosilicate (TEOS) silicon dioxide (SiO2) between CG and FG. Moreover, a lower breakdown voltage between CG and FG was obtained in the fabricated 3D-MOS capacitors as compared with that of planar-MOS capacitors thanks to the enhanced local electric field at the tips of triangular tunnel areas. The developed nanosize triangular cross-sectional tunnel area is useful for the fabrication of low operating voltage flash memories.

  18. Synthesis and electron storage characteristics of isolated silver nanodots on/embedded in Al 2O 3 gate dielectric

    NASA Astrophysics Data System (ADS)

    Wang, Q.; Song, Z. T.; Liu, W. L.; Lin, C. L.; Wang, T. H.

    2004-05-01

    Monolayer-isolated silver (Ag) nanodots with the average diameter down to 7 nm are synthesized on Al 2O 3/Si substrate by vacuum electron-beam evaporation followed by annealing at 400 °C in N 2 ambient. Metal-insulator-silicon (MIS) structures with Ag nanodots embedded in Al 2O 3 gate dielectric are fabricated. Clear electron storage effect with the flatband voltage shift of 1.3 eV is observed through capacitance-conductance and conductance-voltage measurements. Our results demonstrate the feasibility of applying Ag nanodots for nanocrystal floating-gate memory devices.

  19. Microdose Induced Data Loss on Floating Gate Memories

    NASA Technical Reports Server (NTRS)

    Guertin, Steven M.; Nguyen, Duc M.; Patterson, Jeffrey D.

    2006-01-01

    Heavy ion irradiation of flash memories shows loss of stored data. The fluence dependence is indicative of microdose effects. Other qualitative factors identifying the effect as microdose are discussed. The data is presented, and compared to statistical results of a microdose target-based model.

  20. Investing the effectiveness of retention performance in a non-volatile floating gate memory device with a core-shell structure of CdSe nanoparticles

    NASA Astrophysics Data System (ADS)

    Lee, Dong-Hoon; Kim, Jung-Min; Lim, Ki-Tae; Cho, Hyeong Jun; Bang, Jin Ho; Kim, Yong-Sang

    2016-03-01

    In this paper, we empirically investigate the retention performance of organic non-volatile floating gate memory devices with CdSe nanoparticles (NPs) as charge trapping elements. Core-structured CdSe NPs or core-shell-structured ZnS/CdSe NPs were mixed in PMMA and their performance in pentacene based device was compared. The NPs and self-organized thin tunneling PMMA inside the devices exhibited hysteresis by trapping hole during capacitance-voltage characterization. Despite of core-structured NPs showing a larger memory window, the retention time was too short to be adopted by an industry. By contrast core-shell structured NPs showed an improved retention time of >10000 seconds than core-structure NCs. Based on these results and the energy band structure, we propose the retention mechanism of each NPs. This investigation of retention performance provides a comparative and systematic study of the charging/discharging behaviors of NPs based memory devices. [Figure not available: see fulltext.

  1. Effects of Heavy Ion Exposure on Nanocrystal Nonvolatile Memory

    NASA Technical Reports Server (NTRS)

    Oldham, Timothy R.; Suhail, Mohammed; Kuhn, Peter; Prinz, Erwin; Kim, Hak; LaBel, Kenneth A.

    2004-01-01

    We have irradiated engineering samples of Freescale 4M nonvolatile memories with heavy ions. They use Silicon nanocrystals as the storage element, rather than the more common floating gate. The irradiations were performed using the Texas A&M University cyclotron Single Event Effects Test Facility. The chips were tested in the static mode, and in the dynamic read mode, dynamic write (program) mode, and dynamic erase mode. All the errors observed appeared to be due to single, isolated bits, even in the program and erase modes. These errors appeared to be related to the micro-dose mechanism. All the errors corresponded to the loss of electrons from a programmed cell. The underlying physical mechanisms will be discussed in more detail later. There were no errors, which could be attributed to malfunctions of the control circuits. At the highest LET used in the test (85 MeV/mg/sq cm), however, there appeared to be a failure due to gate rupture. Failure analysis is being conducted to confirm this conclusion. There was no unambiguous evidence of latchup under any test conditions. Generally, the results on the nanocrystal technology compare favorably with results on currently available commercial floating gate technology, indicating that the technology is promising for future space applications, both civilian and military.

  2. 152. Photographic copy of original construction drawing dated October 24, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    152. Photographic copy of original construction drawing dated October 24, 1930 (from Record Group 115, Denver Branch of the National Archives, Denver). 60 x 12 RING GATE CONTROL; FLOAT WELL ASSEMBLY AND COVER HOIST STEM-CONNECTION ROD-SLEEVE. - Owyhee Dam, Across Owyhee River, Nyssa, Malheur County, OR

  3. Nonvolatile Memories Using Quantum Dot (QD) Floating Gates Assembled on II-VI Tunnel Insulators

    NASA Astrophysics Data System (ADS)

    Suarez, E.; Gogna, M.; Al-Amoody, F.; Karmakar, S.; Ayers, J.; Heller, E.; Jain, F.

    2010-07-01

    This paper presents preliminary data on quantum dot gate nonvolatile memories using nearly lattice-matched ZnS/Zn0.95Mg0.05S/ZnS tunnel insulators. The GeO x -cladded Ge and SiO x -cladded Si quantum dots (QDs) are self-assembled site-specifically on the II-VI insulator grown epitaxially over the Si channel (formed between the source and drain region). The pseudomorphic II-VI stack serves both as a tunnel insulator and a high- κ dielectric. The effect of Mg incorporation in ZnMgS is also investigated. For the control gate insulator, we have used Si3N4 and SiO2 layers grown by plasma- enhanced chemical vapor deposition.

  4. A MODFET dc model with improved pinchoff and saturation characteristics

    NASA Astrophysics Data System (ADS)

    Rohdin, Hans; Roblin, Patrick

    1986-05-01

    An improved analytical dc model for the MODFET is proposed which uses a new approximation of the two-dimensional electron gas concentration versus gate-to-channel voltage, a ratio which models both the subthreshold region and the gradual saturation of carriers due to the onset of AlGaAs charge modulation. A two-region Grebene-Ghandi model with a floating boundary is used for the channel. A maximum transconductance and a finite intrinsic output conductance in the saturated region are predicted, in agreement with experimental observations. The model is shown to approach the saturated velocity model in the limit of very short gate lengths, and to approach the classical gradual channel model in the limit of very long gate lengths.

  5. Modelling the upwelling offthe east Hainan Island coast in summer 2010

    NASA Astrophysics Data System (ADS)

    Bai, Peng; Gu, Yanzhen; Li, Peiliang; Wu, Kejian

    2016-11-01

    A synoptic-scale upwelling event that developed offthe east coast of the Hainan Island (EHIU) in the summer of 2010 is defined well via processing the Moderate Resolution Imaging Spectroradiometer (MODIS) sea surface temperature (SST) data. The Regional Ocean Modeling System (ROMS) with high spatial resolution has been used to investigate this upwelling event. By comparing the ROMS results against tide station data, Argo float profiles and MODIS SST, it is confirmed that the ROMS reproduces the EHIU well. The cooler-water core (CWC) distinguished by waters < 27.5°C in the EHIU, which occurred in the east Qiongzhou Strait mouth area and was bounded by a high temperature gradient, was the focus of this paper. Vertical structure of the CWC suggests that interaction between the westward flow and the bathymetry slope played a significant role in the formation of CWC. Numerical experiments indicated that the westward flow in the Qiongzhou Strait was the result of tidal rectification over variable topography (Shi et al., 2002), thus tides played a critical role on the development of the CWC. The negative wind stress curl that dominated the east Qiongzhou Strait mouth area suppressed the intensity of the CWC by 0.2-0.4°C. Further, nonlinear interaction between tidal currents and wind stress enhanced vertical mixing greatly, which would benefit the development of the CWC.

  6. Quantum Dot Gate Three-State and Nonvolatile Memory Field-Effect Transistors Using a ZnS/ZnMgS/ZnS Heteroepitaxial Stack as a Tunnel Insulator on Silicon-on-Insulator Substrates

    NASA Astrophysics Data System (ADS)

    Suarez, Ernesto; Chan, Pik-Yiu; Lingalugari, Murali; Ayers, John E.; Heller, Evan; Jain, Faquir

    2013-11-01

    This paper describes the use of II-VI lattice-matched gate insulators in quantum dot gate three-state and flash nonvolatile memory structures. Using silicon-on-insulator wafers we have fabricated GeO x -cladded Ge quantum dot (QD) floating gate nonvolatile memory field-effect transistor devices using ZnS-Zn0.95Mg0.05S-ZnS tunneling layers. The II-VI heteroepitaxial stack is nearly lattice-matched and is grown using metalorganic chemical vapor deposition on a silicon channel. This stack reduces the interface state density, improving threshold voltage variation, particularly in sub-22-nm devices. Simulations using self-consistent solutions of the Poisson and Schrödinger equations show the transfer of charge to the QD layers in three-state as well as nonvolatile memory cells.

  7. Advanced, High Power, Next Scale, Wave Energy Conversion Device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mekhiche, Mike; Dufera, Hiz; Montagna, Deb

    2012-10-29

    The project conducted under DOE contract DE‐EE0002649 is defined as the Advanced, High Power, Next Scale, Wave Energy Converter. The overall project is split into a seven‐stage, gated development program. The work conducted under the DOE contract is OPT Stage Gate III work and a portion of Stage Gate IV work of the seven stage product development process. The project effort includes Full Concept Design & Prototype Assembly Testing building on our existing PowerBuoy technology to deliver a device with much increased power delivery. Scaling‐up from 150kW to 500kW power generating capacity required changes in the PowerBuoy design that addressedmore » cost reduction and mass manufacturing by implementing a Design for Manufacturing (DFM) approach. The design changes also focused on reducing PowerBuoy Installation, Operation and Maintenance (IO&M) costs which are essential to reducing the overall cost of energy. In this design, changes to the core PowerBuoy technology were implemented to increase capability and reduce both CAPEX and OPEX costs. OPT conceptually envisaged moving from a floating structure to a seabed structure. The design change from a floating structure to seabed structure would provide the implementation of stroke‐ unlimited Power Take‐Off (PTO) which has a potential to provide significant power delivery improvement and transform the wave energy industry if proven feasible.« less

  8. Improvements of low-detection-limit filter-free fluorescence sensor developed by charge accumulation operation

    NASA Astrophysics Data System (ADS)

    Tanaka, Kiyotsugu; Choi, Yong Joon; Moriwaki, Yu; Hizawa, Takeshi; Iwata, Tatsuya; Dasai, Fumihiro; Kimura, Yasuyuki; Takahashi, Kazuhiro; Sawada, Kazuaki

    2017-04-01

    We developed a low-detection-limit filter-free fluorescence sensor by a charge accumulation technique. For charge accumulation, a floating diffusion amplifier (FDA), which included a floating diffusion capacitor, a transfer gate, and a source follower circuit, was used. To integrate CMOS circuits with the filter-free fluorescence sensor, we adopted a triple-well process to isolate transistors from the sensor on a single chip. We detected 0.1 nW fluorescence under the illumination of excitation light by 1.5 ms accumulation, which was one order of magnitude greater than that of a previous current detection sensor.

  9. Field programmable gate array-assigned complex-valued computation and its limits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernard-Schwarz, Maria, E-mail: maria.bernardschwarz@ni.com; Institute of Applied Physics, TU Wien, Wiedner Hauptstrasse 8, 1040 Wien; Zwick, Wolfgang

    We discuss how leveraging Field Programmable Gate Array (FPGA) technology as part of a high performance computing platform reduces latency to meet the demanding real time constraints of a quantum optics simulation. Implementations of complex-valued operations using fixed point numeric on a Virtex-5 FPGA compare favorably to more conventional solutions on a central processing unit. Our investigation explores the performance of multiple fixed point options along with a traditional 64 bits floating point version. With this information, the lowest execution times can be estimated. Relative error is examined to ensure simulation accuracy is maintained.

  10. Neural dynamics in reconfigurable silicon.

    PubMed

    Basu, A; Ramakrishnan, S; Petre, C; Koziol, S; Brink, S; Hasler, P E

    2010-10-01

    A neuromorphic analog chip is presented that is capable of implementing massively parallel neural computations while retaining the programmability of digital systems. We show measurements from neurons with Hopf bifurcations and integrate and fire neurons, excitatory and inhibitory synapses, passive dendrite cables, coupled spiking neurons, and central pattern generators implemented on the chip. This chip provides a platform for not only simulating detailed neuron dynamics but also uses the same to interface with actual cells in applications such as a dynamic clamp. There are 28 computational analog blocks (CAB), each consisting of ion channels with tunable parameters, synapses, winner-take-all elements, current sources, transconductance amplifiers, and capacitors. There are four other CABs which have programmable bias generators. The programmability is achieved using floating gate transistors with on-chip programming control. The switch matrix for interconnecting the components in CABs also consists of floating-gate transistors. Emphasis is placed on replicating the detailed dynamics of computational neural models. Massive computational area efficiency is obtained by using the reconfigurable interconnect as synaptic weights, resulting in more than 50 000 possible 9-b accurate synapses in 9 mm(2).

  11. Anomalous annealing of floating gate errors due to heavy ion irradiation

    NASA Astrophysics Data System (ADS)

    Yin, Yanan; Liu, Jie; Sun, Youmei; Hou, Mingdong; Liu, Tianqi; Ye, Bing; Ji, Qinggang; Luo, Jie; Zhao, Peixiong

    2018-03-01

    Using the heavy ions provided by the Heavy Ion Research Facility in Lanzhou (HIRFL), the annealing of heavy-ion induced floating gate (FG) errors in 34 nm and 25 nm NAND Flash memories has been studied. The single event upset (SEU) cross section of FG and the evolution of the errors after irradiation depending on the ion linear energy transfer (LET) values, data pattern and feature size of the device are presented. Different rates of annealing for different ion LET and different pattern are observed in 34 nm and 25 nm memories. The variation of the percentage of different error patterns in 34 nm and 25 nm memories with annealing time shows that the annealing of FG errors induced by heavy-ion in memories will mainly take place in the cells directly hit under low LET ion exposure and other cells affected by heavy ions when the ion LET is higher. The influence of Multiple Cell Upsets (MCUs) on the annealing of FG errors is analyzed. MCUs with high error multiplicity which account for the majority of the errors can induce a large percentage of annealed errors.

  12. Design of a radiation tolerant system for total ionizing dose monitoring using floating gate and RadFET dosimeters

    NASA Astrophysics Data System (ADS)

    Ferraro, R.; Danzeca, S.; Brucoli, M.; Masi, A.; Brugger, M.; Dilillo, L.

    2017-04-01

    The need for upgrading the Total Ionizing Dose (TID) measurement resolution of the current version of the Radiation Monitoring system for the LHC complex has driven the research of new TID sensors. The sensors being developed nowadays can be defined as Systems On Chip (SOC) with both analog and digital circuitries embedded in the same silicon. A radiation tolerant TID Monitoring System (TIDMon) has been designed to allow the placement of the entire dosimeter readout electronics in very harsh environments such as calibration rooms and even in the mixed radiation field such as the one of the LHC complex. The objective of the TIDMon is to measure the effect of the TID on the new prototype of Floating Gate Dosimeter (FGDOS) without using long cables and with a reliable measurement system. This work introduces the architecture of the TIDMon, the radiation tolerance techniques applied on the controlling electronics as well as the design choices adopted for the system. Finally, results of several tests of TIDMon under different radiation environments such as gamma rays or mixed radiation field at CHARM are presented.

  13. Predicting drifter trajectories and particle dispersion in the Caribbean using a high resolution coastal ocean forecasting system

    NASA Astrophysics Data System (ADS)

    Solano, M.

    2016-02-01

    The present study discusses the accuracy of a high-resolution ocean forecasting system in predicting floating drifter trajectories and the uncertainty of modeled particle dispersion in coastal areas. Trajectories were calculated using an offline particle-tracking algorithm coupled to the operational model developed for the region of Puerto Rico by CariCOOS. Both, a simple advection algorithm as well as the Larval TRANSport (LTRANS) model, a more sophisticated offline particle-tracking application, were coupled to the ocean model. Numerical results are compared with 12 floating drifters deployed in the near-shore of Puerto Rico during February and March 2015, and tracked for several days using Global Positioning Systems mounted on the drifters. In addition the trajectories have also been calculated with the AmSeas Navy Coastal Ocean Model (NCOM). The operational model is based on the Regional Ocean Modeling System (ROMS) with a uniform horizontal resolution of 1/100 degrees (1.1km). Initial, surface and open boundary conditions are taken from NCOM, except for wind stress, which is computed using winds from the National Digital Forecasting Database. Probabilistic maps were created to quantify the uncertainty of particle trajectories at different locations. Results show that the forecasted trajectories are location dependent, with tidally active regions having the largest error. The predicted trajectories by both the ROMS and NCOM models show good agreement on average, however both perform differently at particular locations. The effect of wind stress on the drifter trajectories is investigated to account for wind slippage. Furthermore, a real case scenario is presented where simulated trajectories show good agreement when compared to the actual drifter trajectories.

  14. Digital intermediate frequency QAM modulator using parallel processing

    DOEpatents

    Pao, Hsueh-Yuan [Livermore, CA; Tran, Binh-Nien [San Ramon, CA

    2008-05-27

    The digital Intermediate Frequency (IF) modulator applies to various modulation types and offers a simple and low cost method to implement a high-speed digital IF modulator using field programmable gate arrays (FPGAs). The architecture eliminates multipliers and sequential processing by storing the pre-computed modulated cosine and sine carriers in ROM look-up-tables (LUTs). The high-speed input data stream is parallel processed using the corresponding LUTs, which reduces the main processing speed, allowing the use of low cost FPGAs.

  15. High Performance Transparent Transistor Memory Devices Using Nano-Floating Gate of Polymer/ZnO Nanocomposites

    NASA Astrophysics Data System (ADS)

    Shih, Chien-Chung; Lee, Wen-Ya; Chiu, Yu-Cheng; Hsu, Han-Wen; Chang, Hsuan-Chun; Liu, Cheng-Liang; Chen, Wen-Chang

    2016-02-01

    Nano-floating gate memory devices (NFGM) using metal nanoparticles (NPs) covered with an insulating polymer have been considered as a promising electronic device for the next-generation nonvolatile organic memory applications NPs. However, the transparency of the device with metal NPs is restricted to 60~70% due to the light absorption in the visible region caused by the surface plasmon resonance effects of metal NPs. To address this issue, we demonstrate a novel NFGM using the blends of hole-trapping poly (9-(4-vinylphenyl) carbazole) (PVPK) and electron-trapping ZnO NPs as the charge storage element. The memory devices exhibited a remarkably programmable memory window up to 60 V during the program/erase operations, which was attributed to the trapping/detrapping of charge carriers in ZnO NPs/PVPK composite. Furthermore, the devices showed the long-term retention time (>105 s) and WRER test (>200 cycles), indicating excellent electrical reliability and stability. Additionally, the fabricated transistor memory devices exhibited a relatively high transparency of 90% at the wavelength of 500 nm based on the spray-coated PEDOT:PSS as electrode, suggesting high potential for transparent organic electronic memory devices.

  16. An LMS Programming Scheme and Floating-Gate Technology Enabled Trimmer-Less and Low Voltage Flame Detection Sensor.

    PubMed

    Iglesias-Rojas, Juan Carlos; Gomez-Castañeda, Felipe; Moreno-Cadenas, Jose Antonio

    2017-06-14

    In this paper, a Least Mean Square (LMS) programming scheme is used to set the offset voltage of two operational amplifiers that were built using floating-gate transistors, enabling a 0.95 V RMS trimmer-less flame detection sensor. The programming scheme is capable of setting the offset voltage over a wide range of values by means of electron injection. The flame detection sensor consists of two programmable offset operational amplifiers; the first amplifier serves as a 26 μV offset voltage follower, whereas the second amplifier acts as a programmable trimmer-less voltage comparator. Both amplifiers form the proposed sensor, whose principle of functionality is based on the detection of the electrical changes produced by the flame ionization. The experimental results show that it is possible to measure the presence of a flame accurately after programming the amplifiers with a maximum of 35 LMS-algorithm iterations. Current commercial flame detectors are mainly used in absorption refrigerators and large industrial gas heaters, where a high voltage AC source and several mechanical trimmings are used in order to accurately measure the presence of the flame.

  17. Leaky Integrate-and-Fire Neuron Circuit Based on Floating-Gate Integrator

    PubMed Central

    Kornijcuk, Vladimir; Lim, Hyungkwang; Seok, Jun Yeong; Kim, Guhyun; Kim, Seong Keun; Kim, Inho; Choi, Byung Joon; Jeong, Doo Seok

    2016-01-01

    The artificial spiking neural network (SNN) is promising and has been brought to the notice of the theoretical neuroscience and neuromorphic engineering research communities. In this light, we propose a new type of artificial spiking neuron based on leaky integrate-and-fire (LIF) behavior. A distinctive feature of the proposed FG-LIF neuron is the use of a floating-gate (FG) integrator rather than a capacitor-based one. The relaxation time of the charge on the FG relies mainly on the tunnel barrier profile, e.g., barrier height and thickness (rather than the area). This opens up the possibility of large-scale integration of neurons. The circuit simulation results offered biologically plausible spiking activity (<100 Hz) with a capacitor of merely 6 fF, which is hosted in an FG metal-oxide-semiconductor field-effect transistor. The FG-LIF neuron also has the advantage of low operation power (<30 pW/spike). Finally, the proposed circuit was subject to possible types of noise, e.g., thermal noise and burst noise. The simulation results indicated remarkable distributional features of interspike intervals that are fitted to Gamma distribution functions, similar to biological neurons in the neocortex. PMID:27242416

  18. An LMS Programming Scheme and Floating-Gate Technology Enabled Trimmer-Less and Low Voltage Flame Detection Sensor

    PubMed Central

    Iglesias-Rojas, Juan Carlos; Gomez-Castañeda, Felipe; Moreno-Cadenas, Jose Antonio

    2017-01-01

    In this paper, a Least Mean Square (LMS) programming scheme is used to set the offset voltage of two operational amplifiers that were built using floating-gate transistors, enabling a 0.95 VRMS trimmer-less flame detection sensor. The programming scheme is capable of setting the offset voltage over a wide range of values by means of electron injection. The flame detection sensor consists of two programmable offset operational amplifiers; the first amplifier serves as a 26 μV offset voltage follower, whereas the second amplifier acts as a programmable trimmer-less voltage comparator. Both amplifiers form the proposed sensor, whose principle of functionality is based on the detection of the electrical changes produced by the flame ionization. The experimental results show that it is possible to measure the presence of a flame accurately after programming the amplifiers with a maximum of 35 LMS-algorithm iterations. Current commercial flame detectors are mainly used in absorption refrigerators and large industrial gas heaters, where a high voltage AC source and several mechanical trimmings are used in order to accurately measure the presence of the flame. PMID:28613250

  19. Molecular sensing using monolayer floating gate, fully depleted SOI MOSFET acting as an exponential transducer.

    PubMed

    Takulapalli, Bharath R

    2010-02-23

    Field-effect transistor-based chemical sensors fall into two broad categories based on the principle of signal transduction-chemiresistor or Schottky-type devices and MOSFET or inversion-type devices. In this paper, we report a new inversion-type device concept-fully depleted exponentially coupled (FDEC) sensor, using molecular monolayer floating gate fully depleted silicon on insulator (SOI) MOSFET. Molecular binding at the chemical-sensitive surface lowers the threshold voltage of the device inversion channel due to a unique capacitive charge-coupling mechanism involving interface defect states, causing an exponential increase in the inversion channel current. This response of the device is in opposite direction when compared to typical MOSFET-type sensors, wherein inversion current decreases in a conventional n-channel sensor device upon addition of negative charge to the chemical-sensitive device surface. The new sensor architecture enables ultrahigh sensitivity along with extraordinary selectivity. We propose the new sensor concept with the aid of analytical equations and present results from our experiments in liquid phase and gas phase to demonstrate the new principle of signal transduction. We present data from numerical simulations to further support our theory.

  20. Slowing DNA Translocation in a Nanofluidic Field-Effect Transistor.

    PubMed

    Liu, Yifan; Yobas, Levent

    2016-04-26

    Here, we present an experimental demonstration of slowing DNA translocation across a nanochannel by modulating the channel surface charge through an externally applied gate bias. The experiments were performed on a nanofluidic field-effect transistor, which is a monolithic integrated platform featuring a 50 nm-diameter in-plane alumina nanocapillary whose entire length is surrounded by a gate electrode. The field-effect transistor behavior was validated on the gating of ionic conductance and protein transport. The gating of DNA translocation was subsequently studied by measuring discrete current dips associated with single λ-DNA translocation events under a source-to-drain bias of 1 V. The translocation speeds under various gate bias conditions were extracted by fitting event histograms of the measured translocation time to the first passage time distributions obtained from a simple 1D biased diffusion model. A positive gate bias was observed to slow the translocation of single λ-DNA chains markedly; the translocation speed was reduced by an order of magnitude from 18.4 mm/s obtained under a floating gate down to 1.33 mm/s under a positive gate bias of 9 V. Therefore, a dynamic and flexible regulation of the DNA translocation speed, which is vital for single-molecule sequencing, can be achieved on this device by simply tuning the gate bias. The device is realized in a conventional semiconductor microfabrication process without the requirement of advanced lithography, and can be potentially further developed into a compact electronic single-molecule sequencer.

  1. Two-color detection with charge sensitive infrared phototransistors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Sunmi, E-mail: kimsunmi@iis.u-tokyo.ac.jp; Kajihara, Yusuke; Komiyama, Susumu

    2015-11-02

    Highly sensitive two-color detection is demonstrated at wavelengths of 9 μm and 14.5 μm by using a charge sensitive infrared phototransistor fabricated in a triple GaAs/AlGaAs quantum well (QW) crystal. Two differently thick QWs (7 nm- and 9 nm-thicknesses) serve as photosensitive floating gates for the respective wavelengths via intersubband excitation: The excitation in the QWs is sensed by a third QW, which works as a conducting source-drain channel in the photosensitive transistor. The two spectral bands of detection are shown to be controlled by front-gate biasing, providing a hint for implementing voltage tunable ultra-highly sensitive detectors.

  2. EMG activity of hip and trunk muscles during deep-water running.

    PubMed

    Kaneda, Koichi; Sato, Daisuke; Wakabayashi, Hitoshi; Nomura, Takeo

    2009-12-01

    The present study used synchronized motion analysis to investigate the activity of hip and trunk muscles during deep-water running (DWR) relative to land walking (LW) and water walking (WW). Nine healthy men performed each exercise at self-determined slow, moderate, and fast paces, and surface electromyography was used to investigate activity of the adductor longus, gluteus maxima, gluteus medius, rectus abdominis, oblique externus abdominis, and erector spinae. The following kinematic parameters were calculated: the duration of one cycle, range of motion (ROM) of the hip joint, and absolute angles of the pelvis and trunk with respect to the vertical axis in the sagittal plane. The percentages of maximal voluntary contraction (%MVC) of each muscle were higher during DWR than during LW and WW. The %MVC of the erector spinae during WW increased concomitant with the pace increment. The hip joint ROMs were larger in DWR than in LW and WW. Forward inclinations of the trunk were apparent for DWR and fast-paced WW. The pelvis was inclined forward in DWR and WW. In conclusion, the higher-level activities during DWR are affected by greater hip joint motion and body inclinations with an unstable floating situation.

  3. Development of the Field-Induced Electron Injection and Impact Ionization (F4I) Technique for Radiation Hardness Testing of MOS (Metal-Oxide-Semiconductor) Gate Insulators.

    DTIC Science & Technology

    1988-03-01

    Applesoft language, a variant of floating-point BASIC that is supplied with the computer. As an intepreted language, Apple- soft BASIC executes fairly...fit with (VI , II ) array. I 8400 Sound bell and display warning when current limit exceeded. 8500-8510 Output HV pulse, read and display amplitude

  4. Bringing the medical library to the office desktop.

    PubMed

    Brown, S R; Decker, G; Pletzke, C J

    1991-01-01

    This demonstration illustrates LRC Remote Computer Services- a dual operating system, multi-protocol system for delivering medical library services to the medical professional's desktop. A working model draws resources from CD-ROM and magnetic media file services, Novell and AppleTalk network protocol suites and gating, LAN and asynchronous (dial-in) access strategies, commercial applications for MS-DOS and Macintosh workstations and custom user interfaces. The demonstration includes a discussion of issues relevant to the delivery of said services, particularly with respect to maintenance, security, training/support, staffing, software licensing and costs.

  5. Multi-terminal memtransistors from polycrystalline monolayer molybdenum disulfide

    NASA Astrophysics Data System (ADS)

    Sangwan, Vinod K.; Lee, Hong-Sub; Bergeron, Hadallia; Balla, Itamar; Beck, Megan E.; Chen, Kan-Sheng; Hersam, Mark C.

    2018-02-01

    Memristors are two-terminal passive circuit elements that have been developed for use in non-volatile resistive random-access memory and may also be useful in neuromorphic computing. Memristors have higher endurance and faster read/write times than flash memory and can provide multi-bit data storage. However, although two-terminal memristors have demonstrated capacity for basic neural functions, synapses in the human brain outnumber neurons by more than a thousandfold, which implies that multi-terminal memristors are needed to perform complex functions such as heterosynaptic plasticity. Previous attempts to move beyond two-terminal memristors, such as the three-terminal Widrow-Hoff memristor and field-effect transistors with nanoionic gates or floating gates, did not achieve memristive switching in the transistor. Here we report the experimental realization of a multi-terminal hybrid memristor and transistor (that is, a memtransistor) using polycrystalline monolayer molybdenum disulfide (MoS2) in a scalable fabrication process. The two-dimensional MoS2 memtransistors show gate tunability in individual resistance states by four orders of magnitude, as well as large switching ratios, high cycling endurance and long-term retention of states. In addition to conventional neural learning behaviour of long-term potentiation/depression, six-terminal MoS2 memtransistors have gate-tunable heterosynaptic functionality, which is not achievable using two-terminal memristors. For example, the conductance between a pair of floating electrodes (pre- and post-synaptic neurons) is varied by a factor of about ten by applying voltage pulses to modulatory terminals. In situ scanning probe microscopy, cryogenic charge transport measurements and device modelling reveal that the bias-induced motion of MoS2 defects drives resistive switching by dynamically varying Schottky barrier heights. Overall, the seamless integration of a memristor and transistor into one multi-terminal device could enable complex neuromorphic learning and the study of the physics of defect kinetics in two-dimensional materials.

  6. Configurable hardware integrate and fire neurons for sparse approximation.

    PubMed

    Shapero, Samuel; Rozell, Christopher; Hasler, Paul

    2013-09-01

    Sparse approximation is an important optimization problem in signal and image processing applications. A Hopfield-Network-like system of integrate and fire (IF) neurons is proposed as a solution, using the Locally Competitive Algorithm (LCA) to solve an overcomplete L1 sparse approximation problem. A scalable system architecture is described, including IF neurons with a nonlinear firing function, and current-based synapses to provide linear computation. A network of 18 neurons with 12 inputs is implemented on the RASP 2.9v chip, a Field Programmable Analog Array (FPAA) with directly programmable floating gate elements. Said system uses over 1400 floating gates, the largest system programmed on a FPAA to date. The circuit successfully reproduced the outputs of a digital optimization program, converging to within 4.8% RMS, and an objective cost only 1.7% higher on average. The active circuit consumed 559 μA of current at 2.4 V and converges on solutions in 25 μs, with measurement of the converged spike rate taking an additional 1 ms. Extrapolating the scaling trends to a N=1000 node system, the spiking LCA compares favorably with state-of-the-art digital solutions, and analog solutions using a non-spiking approach. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Floating gate memory with charge storage dots array formed by Dps protein modified with site-specific binding peptides

    NASA Astrophysics Data System (ADS)

    Kamitake, Hiroki; Uenuma, Mutsunori; Okamoto, Naofumi; Horita, Masahiro; Ishikawa, Yasuaki; Yamashita, Ichro; Uraoka, Yukiharu

    2015-05-01

    We report a nanodot (ND) floating gate memory (NFGM) with a high-density ND array formed by a biological nano process. We utilized two kinds of cage-shaped proteins displaying SiO2 binding peptide (minTBP-1) on their outer surfaces: ferritin and Dps, which accommodate cobalt oxide NDs in their cavities. The diameters of the cobalt NDs were regulated by the cavity sizes of the proteins. Because minTBP-1 is strongly adsorbed on the SiO2 surface, high-density cobalt oxide ND arrays were obtained by a simple spin coating process. The densities of cobalt oxide ND arrays based on ferritin and Dps were 6.8 × 1011 dots cm-2 and 1.2 × 1012 dots cm-2, respectively. After selective protein elimination and embedding in a metal-oxide-semiconductor (MOS) capacitor, the charge capacities of both ND arrays were evaluated by measuring their C-V characteristics. The MOS capacitor embedded with the Dps ND array showed a wider memory window than the device embedded with the ferritin ND array. Finally, we fabricated an NFGM with a high-density ND array based on Dps, and confirmed its competent writing/erasing characteristics and long retention time.

  8. Detection of charge storage on molecular thin films of tris(8-hydroxyquinoline) aluminum (Alq3) by Kelvin force microscopy: a candidate system for high storage capacity memory cells.

    PubMed

    Paydavosi, Sarah; Aidala, Katherine E; Brown, Patrick R; Hashemi, Pouya; Supran, Geoffrey J; Osedach, Timothy P; Hoyt, Judy L; Bulović, Vladimir

    2012-03-14

    Retention and diffusion of charge in tris(8-hydroxyquinoline) aluminum (Alq(3)) molecular thin films are investigated by injecting electrons and holes via a biased conductive atomic force microscopy tip into the Alq(3) films. After the charge injection, Kelvin force microscopy measurements reveal minimal changes with time in the spatial extent of the trapped charge domains within Alq(3) films, even for high hole and electron densities of >10(12) cm(-2). We show that this finding is consistent with the very low mobility of charge carriers in Alq(3) thin films (<10(-7) cm(2)/(Vs)) and that it can benefit from the use of Alq(3) films as nanosegmented floating gates in flash memory cells. Memory capacitors using Alq(3) molecules as the floating gate are fabricated and measured, showing durability over more than 10(4) program/erase cycles and the hysteresis window of up to 7.8 V, corresponding to stored charge densities as high as 5.4 × 10(13) cm(-2). These results demonstrate the potential for use of molecular films in high storage capacity nonvolatile memory cells. © 2012 American Chemical Society

  9. Charge retention characteristics of silicide-induced crystallized polycrystalline silicon floating gate thin-film transistors for active matrix organic light-emitting diode.

    PubMed

    Park, Jae Hyo; Son, Se Wan; Byun, Chang Woo; Kim, Hyung Yoon; Joo, So Na; Lee, Yong Woo; Yun, Seung Jae; Joo, Seung Ki

    2013-10-01

    In this work, non-volatile memory thin-film transistor (NVM-TFT) was fabricated by nickel silicide-induced laterally crystallized (SILC) polycrystalline silicon (poly-Si) as the active layer. The nickel seed silicide-induced crystallized (SIC) poly-Si was used as storage layer which is embedded in the gate insulator. The novel unit pixel of active matrix organic light-emitting diode (AMOLED) using NVM-TFT is proposed and investigated the electrical and optical performance. The threshold voltage shift showed 17.2 V and the high reliability of retention characteristic was demonstrated until 10 years. The retention time can modulate the recharge refresh time of the unit pixel of AMOLED up to 5000 sec.

  10. Research in the design of high-performance reconfigurable systems

    NASA Technical Reports Server (NTRS)

    Slotnick, D. L.; Mcewan, S. D.; Spry, A. J.

    1984-01-01

    An initial design for the Bit Processor (BP) referred to in prior reports as the Processing Element or PE has been completed. Eight BP's, together with their supporting random-access memory, a 64 k x 9 ROM to perform addition, routing logic, and some additional logic, constitute the components of a single stage. An initial stage design is given. Stages may be combined to perform high-speed fixed or floating point arithmetic. Stages can be configured into a range of arithmetic modules that includes bit-serial one or two-dimensional arrays; one or two dimensional arrays fixed or floating point processors; and specialized uniprocessors, such as long-word arithmetic units. One to eight BP's represent a likely initial chip level. The Stage would then correspond to a first-level pluggable module. As both this project and VLSI CAD/CAM progress, however, it is expected that the chip level would migrate upward to the stage and, perhaps, ultimately the box level. The BP RAM, consisting of two banks, holds only operands and indices. Programs are at the box (high-level function) and system level. At the system level initial effort has been concentrated on specifying the tools needed to evaluate design alternatives.

  11. Gating based on internal/external signals with dynamic correlation updates.

    PubMed

    Wu, Huanmei; Zhao, Qingya; Berbeco, Ross I; Nishioka, Seiko; Shirato, Hiroki; Jiang, Steve B

    2008-12-21

    Precise localization of mobile tumor positions in real time is critical to the success of gated radiotherapy. Tumor positions are usually derived from either internal or external surrogates. Fluoroscopic gating based on internal surrogates, such as implanted fiducial markers, is accurate however requiring a large amount of imaging dose. Gating based on external surrogates, such as patient abdominal surface motion, is non-invasive however less accurate due to the uncertainty in the correlation between tumor location and external surrogates. To address these complications, we propose to investigate an approach based on hybrid gating with dynamic internal/external correlation updates. In this approach, the external signal is acquired at high frequency (such as 30 Hz) while the internal signal is sparsely acquired (such as 0.5 Hz or less). The internal signal is used to validate and update the internal/external correlation during treatment. Tumor positions are derived from the external signal based on the newly updated correlation. Two dynamic correlation updating algorithms are introduced. One is based on the motion amplitude and the other is based on the motion phase. Nine patients with synchronized internal/external motion signals are simulated retrospectively to evaluate the effectiveness of hybrid gating. The influences of different clinical conditions on hybrid gating, such as the size of gating windows, the optimal timing for internal signal acquisition and the acquisition frequency are investigated. The results demonstrate that dynamically updating the internal/external correlation in or around the gating window will reduce false positive with relatively diminished treatment efficiency. This improvement will benefit patients with mobile tumors, especially greater for early stage lung cancers, for which the tumors are less attached or freely floating in the lung.

  12. Materials and methods for the preparation of nanocomposites

    DOEpatents

    Nag, Angshuman; Talapin, Dmitri V.

    2018-01-30

    Disclosed herein is an isolable colloidal particle comprising a nanoparticle and an inorganic capping agent bound to the surface of the nanoparticle, a method for making the same in a biphasic solvent mixture, and the formation of structures and solids from the isolable colloidal particle. The process can yield photovoltaic cells, piezoelectric crystals, thermoelectric layers, optoelectronic layers, light emitting diodes, ferroelectric layers, thin film transistors, floating gate memory devices, phase change layers, and sensor devices.

  13. Low-altitude photographic transects of the Arctic network of national park units and Selawik National Wildlife Refuge, Alaska, July 2013

    Treesearch

    Bruce G. Marcot; M. Torre Jorgenson; Anthony R. DeGange

    2014-01-01

    During July 16–18, 2013, low-level photography flights were conducted (with a Cessna 185 with floats and a Cessna 206 with tundra tires) over the five administrative units of the National Park Service Arctic Network (Bering Land Bridge National Preserve, Cape Krusenstern National Monument, Gates of the Arctic National Park and Preserve, Kobuk Valley National Park, and...

  14. A randomization approach to handling data scaling in nuclear medicine.

    PubMed

    Bai, Chuanyong; Conwell, Richard; Kindem, Joel

    2010-06-01

    In medical imaging, data scaling is sometimes desired to handle the system complexity, such as uniformity calibration. Since the data are usually saved in short integer, conventional data scaling will first scale the data in floating point format and then truncate or round the floating point data to short integer data. For example, when using truncation, scaling of 9 by 1.1 results in 9 and scaling of 10 by 1.1 results in 11. When the count level is low, such scaling may change the local data distribution and affect the intended application of the data. In this work, the authors use an example gated cardiac SPECT study to illustrate the effect of conventional scaling by factors of 1.1 and 1.2. The authors then scaled the data with the same scaling factors using a randomization approach, in which a random number evenly distributed between 0 and 1 is generated to determine how the floating point data will be saved as short integer data. If the random number is between 0 and 0.9, then 9.9 will be saved as 10, otherwise 9. In other words, the floating point value 9.9 will be saved in short integer value as 10 with 90% probability or 9 with 10% probability. For statistical analysis of the performance, the authors applied the conventional approach with rounding and the randomization approach to 50 consecutive gated studies from a clinical site. For the example study, the image reconstructed from the original data showed an apparent perfusion defect at the apex of the myocardium. The defect size was noticeably changed by scaling with 1.1 and 1.2 using the conventional approaches with truncation and rounding. Using the randomization approach, in contrast, the images from the scaled data appeared identical to the original image. Line profile analysis of the scaled data showed that the randomization approach introduced the least change to the data as compared to the conventional approaches. For the 50 gated data sets, significantly more studies showed quantitative differences between the original images and the images from the data scaled by 1.2 using the rounding approach than the randomization approach [46/50 (92%) versus 3/50 (6%), p < 0.05]. Likewise, significantly more studies showed visually noticeable differences between the original images and the images from the data scaled by 1.2 using the rounding approach than randomization [29/50 (58%) versus 1/50 (2%), p < 0.05]. In conclusion, the proposed randomization approach minimizes the scaling-introduced local data change as compared to the conventional approaches. It is preferred for nuclear medicine data scaling.

  15. Modifications of traps to reduce bycatch of freshwater turtles

    USGS Publications Warehouse

    Bury, R. Bruce

    2011-01-01

    Mortality of freshwater turtles varies among types and deployments of traps. There are few or no losses in hoop or fyke traps set where turtles may reach air, including placement in shallows, addition of floats on traps, and tying traps securely to a stake or to shore. Turtle mortality occurs when traps are set deep, traps are checked at intervals >1 day, and when turtles are captured as bycatch. Devices are available that exclude turtles from traps set for crab or game fish harvest. Slotted gates in front of the trap mouth reduce turtle entry, but small individuals still may be trapped. Incidental take of turtles is preventable by integrating several designs into aquatic traps, such as adding floats to the top of traps so turtles may reach air or an extension tube (chimney, ramp) that creates an escape route.

  16. Review of mixer design for low voltage - low power applications

    NASA Astrophysics Data System (ADS)

    Nurulain, D.; Musa, F. A. S.; Isa, M. Mohamad; Ahmad, N.; Kasjoo, S. R.

    2017-09-01

    A mixer is used in almost all radio frequency (RF) or microwave systems for frequency translation. Nowadays, the increase market demand encouraged the industry to deliver circuit designs to create proficient and convenient equipment with very low power (LP) consumption and low voltage (LV) supply in both digital and analogue circuits. This paper focused on different Complementary Metal Oxide Semiconductor (CMOS) design topologies for LV and LP mixer design. Floating Gate Metal Oxide Semiconductor (FGMOS) is an alternative technology to replace CMOS due to their high ability for LV and LP applications. FGMOS only required a few transistors per gate and can have a shift in threshold voltage (VTH) to increase the LP and LV performances as compared to CMOS, which makes an attractive option to replace CMOS.

  17. Investigation of High-k Dielectrics and Metal Gate Electrodes for Non-volatile Memory Applications

    NASA Astrophysics Data System (ADS)

    Jayanti, Srikant

    Due to the increasing demand of non-volatile flash memories in the portable electronics, the device structures need to be scaled down drastically. However, the scalability of traditional floating gate structures beyond 20 nm NAND flash technology node is uncertain. In this regard, the use of metal gates and high-k dielectrics as the gate and interpoly dielectrics respectively, seem to be promising substitutes in order to continue the flash scaling beyond 20nm. Furthermore, research of novel memory structures to overcome the scaling challenges need to be explored. Through this work, the use of high-k dielectrics as IPDs in a memory structure has been studied. For this purpose, IPD process optimization and barrier engineering were explored to determine and improve the memory performance. Specifically, the concept of high-k / low-k barrier engineering was studied in corroboration with simulations. In addition, a novel memory structure comprising a continuous metal floating gate was investigated in combination with high-k blocking oxides. Integration of thin metal FGs and high-k dielectrics into a dual floating gate memory structure to result in both volatile and non-volatile modes of operation has been demonstrated, for plausible application in future unified memory architectures. The electrical characterization was performed on simple MIS/MIM and memory capacitors, fabricated through CMOS compatible processes. Various analytical characterization techniques were done to gain more insight into the material behavior of the layers in the device structure. In the first part of this study, interfacial engineering was investigated by exploring La2O3 as SiO2 scavenging layer. Through the silicate formation, the consumption of low-k SiO2 was controlled and resulted in a significant improvement in dielectric leakage. The performance improvement was also gauged through memory capacitors. In the second part of the study, a novel memory structure consisting of continuous metal FG in the form of PVD TaN was investigated along with high-k blocking dielectric. The material properties of TaN metal and high-k / low-k dielectric engineering were systematically studied. And the resulting memory structures exhibit excellent memory characteristics and scalability of the metal FG down to ˜1nm, which is promising in order to reduce the unwanted FG-FG interferences. In the later part of the study, the thermal stability of the combined stack was examined and various approaches to improve the stability and understand the cause of instability were explored. The performance of the high-k IPD metal FG memory structure was observed to degrade with higher annealing conditions and the deteriorated behavior was attributed to the leakage instability of the high-k /TaN capacitor. While the degradation is pronounced in both MIM and MIS capacitors, a higher leakage increment was seen in MIM, which was attributed to the higher degree of dielectric crystallization. In an attempt to improve the thermal stability, the trade-off in using amorphous interlayers to reduce the enhanced dielectric crystallization on metal was highlighted. Also, the effect of oxygen vacancies and grain growth on the dielectric leakage was studied through a multi-deposition-multi-anneal technique. Multi step deposition and annealing in a more electronegative ambient was observed to have a positive impact on the dielectric performance.

  18. Nanocrystals embedded in hafnium dioxide-based dielectrics as charge storage nodes of nano-floating gate memory

    NASA Astrophysics Data System (ADS)

    Lee, Pui Fai

    2007-12-01

    Nanocrystals (NC) embedded in dielectrics have attracted a great deal of attention recently because they can potentially be applied in nonvolatile, high-speed, high-density and low-power memory devices. This device benefits from a relatively low operating voltage, high endurance, fast write-erase speeds and better immunity to soft errors. The nanocrystal materials suitable for such an application can be either metals or semiconductors. Recent studies have shown that high-k dielectrics, instead of SiO2 , for the tunneling layer in nanocrystal floating gate memory can improve the trade-off between data retention and program efficiency due to the unique band alignment of high-k dielectrics in the programming and retention modes. In this project, HfAlO has been selected as the high- k dielectric for the nanocrystal floating gate memory structure. The trilayer structure (HfAlO/Ge-NC/HfAlO) on Si was fabricated by PLD. Results revealed that relatively low substrate temperature and growth rate are favourable for the formation of smaller-size Ge nanocrystals. Effects of size/density of the Ge nanocrystal, the tunneling and control oxide layer thicknesses and the oxygen partial pressure during their growth on the charge storage and charge retention characteristics have also been studied. The island structure of the Ge nanocrystal suggests that the growth is based on the Volmer-Webber mode. The self-organized Ge nanocrystals so formed were uniform in size (5--20 nm diameter) and distribution with a density approaching 1012--1013cm-2. Flat-band voltage shift (DeltaVFB) of about 3.6 V and good retention property have been achieved. By varying aggregation distance, sputtering gas pressure and ionization power of the nanocluster source, nanoclusters of Ge with different sizes can be formed. The memory effect of the trilayer structure so formed with 10 nm Ge nanoclusters are manifested by the counter-clockwise hysteresis loop in the C-V curves and a maximum flat-band voltage shift of 5.0 V has been achieved. For comparison purposes, metal nanocrystals have also been investigated by utilizing both of the physical deposition methods as mentioned above. Silver (Ag) nanocrystals with size of 10--40 nm have been embedded in HfAlO matrix in the trilayer capacitor structure and a flat-band voltage shift of 2.0 V has been achieved.

  19. Fabrication and characteristics of MOSFET protein chip for detection of ribosomal protein.

    PubMed

    Park, Keun-Yong; Kim, Min-Suk; Choi, Sie-Young

    2005-04-15

    A metal oxide silicon field effect transistor (MOSFET) protein chip for the easy detection of protein was fabricated and its characteristics were investigated. Generally, the drain current of the MOSFET is varied by the gate potential. It is expected that the formation of an antibody-antigen complex on the gate of MOSFET would lead to a detectable change in the charge distribution and thus, directly modulate the drain current of MOSFET. As such, the drain current of the MOSFET protein chip can be varied by ribosomal proteins absorbed by the self-assembled monolayer (SAM) immobilized on the gate (Au) surface, as ribosomal protein has positive charge, and these current variations then used as the response of the protein chip. The gate of MOSFET protein chip is not directly biased by an external voltage source, so called open gate or floating gate MOSFET, but rather chemically modified by immobilized molecular receptors called self-assembled monolayer (SAM). In our experiments, the current variation in the proposed protein chip was about 8% with a protein concentration of 0.7 mM. As the protein concentration increased, the drain current also gradually increased. In addition, there were some drift of the drain current in the device. It is considered that these drift might be caused by the drift from the MOSFET itself or protein absorption procedures that are relied on the facile attachment of thiol (-S) ligands to the gate (Au) surface. We verified the formation of SAM on the gold surface and the absorption of protein through the surface plasmon resonance (SPR) measurement.

  20. Enhanced biosensing resolution with foundry fabricated individually addressable dual-gated ISFETs.

    PubMed

    Duarte-Guevara, Carlos; Lai, Fei-Lung; Cheng, Chun-Wen; Reddy, Bobby; Salm, Eric; Swaminathan, Vikhram; Tsui, Ying-Kit; Tuan, Hsiao Chin; Kalnitsky, Alex; Liu, Yi-Shao; Bashir, Rashid

    2014-08-19

    The adaptation of semiconductor technologies for biological applications may lead to a new era of inexpensive, sensitive, and portable diagnostics. At the core of these developing technologies is the ion-sensitive field-effect transistor (ISFET), a biochemical to electrical transducer with seamless integration to electronic systems. We present a novel structure for a true dual-gated ISFET that is fabricated with a silicon-on-insulator (SOI) complementary metal-oxide-semiconductor process by Taiwan Semiconductor Manufacturing Company (TSMC). In contrast to conventional SOI ISFETs, each transistor has an individually addressable back-gate and a gate oxide that is directly exposed to the solution. The elimination of the commonly used floating gate architecture reduces the chance of electrostatic discharge and increases the potential achievable transistor density. We show that when operated in a "dual-gate" mode, the transistor response can exhibit sensitivities to pH changes beyond the Nernst limit. This enhancement in sensitivity was shown to increase the sensor's signal-to-noise ratio, allowing the device to resolve smaller pH changes. An improved resolution can be used to enhance small signals and increase the sensor accuracy when monitoring small pH dynamics in biological reactions. As a proof of concept, we demonstrate that the amplified sensitivity and improved resolution result in a shorter detection time and a larger output signal of a loop-mediated isothermal DNA amplification reaction (LAMP) targeting a pathogenic bacteria gene, showing benefits of the new structure for biosensing applications.

  1. Repair, Evaluation, Maintenance, and Rehabilitation Research Program. Floating Debris Control; A Literature Review.

    DTIC Science & Technology

    1987-06-01

    Debris diversion boom and debris, Appalachian Power Company Station at Winfield Lock and Dam, Kanavha River, West Virginia. Than, T 9 (sin a) - 1.94...control dam. Central gate Is blocked partly open causing .ime downstream scour. Water flows right to left. BOTTOM-Debris diversion boom and debris... Appalachian Power Company Station at Winfield Lock and Dam, Kanawha River, West Virginia. - 0 .’ Unclass ified SECURITY CLASSIFICATION OF THIS PAGE for- 40

  2. Radiation Effects on Advanced Flash Memories

    NASA Technical Reports Server (NTRS)

    Nguyen, D. N.; Guertin, S.; Swift, G. M.; Johnston, A. H.

    1998-01-01

    Flash memories have evolved very rapidly in recent ears. New design techniques such as multilevel storage have been proposed to increase storage density, and are now available commercially. Threshold voltage distributions for single- and three-level technologies are compared. In order to implement this technology special circuitry must be added to allow the amount of charge stored in the floating gate to be controlled within narrow limits during the writing and also to detect the different amounts of charge during reading.

  3. A novel micromixer based on the alternating current-flow field effect transistor.

    PubMed

    Wu, Yupan; Ren, Yukun; Tao, Ye; Hou, Likai; Hu, Qingming; Jiang, Hongyuan

    2016-12-20

    Induced-charge electroosmosis (ICEO) phenomena have been attracting considerable attention as a means for pumping and mixing in microfluidic systems with the advantage of simple structures and low-energy consumption. We propose the first effort to exploit a fixed-potential ICEO flow around a floating electrode for microfluidic mixing. In analogy with the field effect transistor (FET) in microelectronics, the floating electrode act as a "gate" electrode for generating asymmetric ICEO flow and thus the device is called an AC-flow FET (AC-FFET). We take advantage of a tandem electrode configuration containing two biased center metal strips arranged in sequence at the bottom of the channel to generate asymmetric vortexes. The current device is manufactured on low-cost glass substrates via an easy and reliable process. Mixing experiments were conducted in the proposed device and the comparison between simulation and experimental results was also carried out, which indicates that the micromixer permits an efficient mixing effect. The mixing performance can be further enhanced by the application of a suitable phase difference between the driving electrode and the gate electrode or a square wave signal. Finally, we performed a critical analysis of the proposed micromixer in comparison with different mixer designs using a comparative mixing index (CMI). The novel methods put forward here offer a simple solution to mixing issues in microfluidic systems.

  4. Dielectrophoresis-Assisted Integration of 1024 Carbon Nanotube Sensors into a CMOS Microsystem.

    PubMed

    Seichepine, Florent; Rothe, Jörg; Dudina, Alexandra; Hierlemann, Andreas; Frey, Urs

    2017-05-01

    Carbon-nanotube (CNT)-based sensors offer the potential to detect single-molecule events and picomolar analyte concentrations. An important step toward applications of such nanosensors is their integration in large arrays. The availability of large arrays would enable multiplexed and parallel sensing, and the simultaneously obtained sensor signals would facilitate statistical analysis. A reliable method to fabricate an array of 1024 CNT-based sensors on a fully processed complementary-metal-oxide-semiconductor microsystem is presented. A high-yield process for the deposition of CNTs from a suspension by means of liquid-coupled floating-electrode dielectrophoresis (DEP), which yielded 80% of the sensor devices featuring between one and five CNTs, is developed. The mechanism of floating-electrode DEP on full arrays and individual devices to understand its self-limiting behavior is studied. The resistance distributions across the array of CNT devices with respect to different DEP parameters are characterized. The CNT devices are then operated as liquid-gated CNT field-effect-transistors (LG-CNTFET) in liquid environment. Current dependency to the gate voltage of up to two orders of magnitude is recorded. Finally, the sensors are validated by studying the pH dependency of the LG-CNTFET conductance and it is demonstrated that 73% of the CNT sensors of a given microsystem show a resistance decrease upon increasing the pH value. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Non-Faradaic Electrochemical Detection of Exocytosis from Mast and Chromaffin Cells Using Floating-Gate MOS Transistors.

    PubMed

    Jayant, Krishna; Singhai, Amit; Cao, Yingqiu; Phelps, Joshua B; Lindau, Manfred; Holowka, David A; Baird, Barbara A; Kan, Edwin C

    2015-12-21

    We present non-faradaic electrochemical recordings of exocytosis from populations of mast and chromaffin cells using chemoreceptive neuron MOS (CνMOS) transistors. In comparison to previous cell-FET-biosensors, the CνMOS features control (CG), sensing (SG) and floating gates (FG), allows the quiescent point to be independently controlled, is CMOS compatible and physically isolates the transistor channel from the electrolyte for stable long-term recordings. We measured exocytosis from RBL-2H3 mast cells sensitized by IgE (bound to high-affinity surface receptors FcεRI) and stimulated using the antigen DNP-BSA. Quasi-static I-V measurements reflected a slow shift in surface potential () which was dependent on extracellular calcium ([Ca]o) and buffer strength, which suggests sensitivity to protons released during exocytosis. Fluorescent imaging of dextran-labeled vesicle release showed evidence of a similar time course, while un-sensitized cells showed no response to stimulation. Transient recordings revealed fluctuations with a rapid rise and slow decay. Chromaffin cells stimulated with high KCl showed both slow shifts and extracellular action potentials exhibiting biphasic and inverted capacitive waveforms, indicative of varying ion-channel distributions across the cell-transistor junction. Our approach presents a facile method to simultaneously monitor exocytosis and ion channel activity with high temporal sensitivity without the need for redox chemistry.

  6. Technology breakthroughs in high performance metal-oxide-semiconductor devices for ultra-high density, low power non-volatile memory applications

    NASA Astrophysics Data System (ADS)

    Hong, Augustin Jinwoo

    Non-volatile memory devices have attracted much attention because data can be retained without power consumption more than a decade. Therefore, non-volatile memory devices are essential to mobile electronic applications. Among state of the art non-volatile memory devices, NAND flash memory has earned the highest attention because of its ultra-high scalability and therefore its ultra-high storage capacity. However, human desire as well as market competition requires not only larger storage capacity but also lower power consumption for longer battery life time. One way to meet this human desire and extend the benefits of NAND flash memory is finding out new materials for storage layer inside the flash memory, which is called floating gate in the state of the art flash memory device. In this dissertation, we study new materials for the floating gate that can lower down the power consumption and increase the storage capacity at the same time. To this end, we employ various materials such as metal nanodot, metal thin film and graphene incorporating complementary-metal-oxide-semiconductor (CMOS) compatible processes. Experimental results show excellent memory effects at relatively low operating voltages. Detailed physics and analysis on experimental results are discussed. These new materials for data storage can be promising candidates for future non-volatile memory application beyond the state of the art flash technologies.

  7. Non-Faradaic Electrochemical Detection of Exocytosis from Mast and Chromaffin Cells Using Floating-Gate MOS Transistors

    PubMed Central

    Jayant, Krishna; Singhai, Amit; Cao, Yingqiu; Phelps, Joshua B.; Lindau, Manfred; Holowka, David A.; Baird, Barbara A.; Kan, Edwin C.

    2015-01-01

    We present non-faradaic electrochemical recordings of exocytosis from populations of mast and chromaffin cells using chemoreceptive neuron MOS (CνMOS) transistors. In comparison to previous cell-FET-biosensors, the CνMOS features control (CG), sensing (SG) and floating gates (FG), allows the quiescent point to be independently controlled, is CMOS compatible and physically isolates the transistor channel from the electrolyte for stable long-term recordings. We measured exocytosis from RBL-2H3 mast cells sensitized by IgE (bound to high-affinity surface receptors FcεRI) and stimulated using the antigen DNP-BSA. Quasi-static I-V measurements reflected a slow shift in surface potential () which was dependent on extracellular calcium ([Ca]o) and buffer strength, which suggests sensitivity to protons released during exocytosis. Fluorescent imaging of dextran-labeled vesicle release showed evidence of a similar time course, while un-sensitized cells showed no response to stimulation. Transient recordings revealed fluctuations with a rapid rise and slow decay. Chromaffin cells stimulated with high KCl showed both slow shifts and extracellular action potentials exhibiting biphasic and inverted capacitive waveforms, indicative of varying ion-channel distributions across the cell-transistor junction. Our approach presents a facile method to simultaneously monitor exocytosis and ion channel activity with high temporal sensitivity without the need for redox chemistry. PMID:26686301

  8. System and method for floating-substrate passive voltage contrast

    DOEpatents

    Jenkins, Mark W [Albuquerque, NM; Cole, Jr., Edward I.; Tangyunyong, Paiboon [Albuquerque, NM; Soden, Jerry M [Placitas, NM; Walraven, Jeremy A [Albuquerque, NM; Pimentel, Alejandro A [Albuquerque, NM

    2009-04-28

    A passive voltage contrast (PVC) system and method are disclosed for analyzing ICs to locate defects and failure mechanisms. During analysis a device side of a semiconductor die containing the IC is maintained in an electrically-floating condition without any ground electrical connection while a charged particle beam is scanned over the device side. Secondary particle emission from the device side of the IC is detected to form an image of device features, including electrical vias connected to transistor gates or to other structures in the IC. A difference in image contrast allows the defects or failure mechanisms be pinpointed. Varying the scan rate can, in some instances, produce an image reversal to facilitate precisely locating the defects or failure mechanisms in the IC. The system and method are useful for failure analysis of ICs formed on substrates (e.g. bulk semiconductor substrates and SOI substrates) and other types of structures.

  9. Patterns in connectivity and retention of simulated Tanner crab (Chionoecetes bairdi) larvae in the eastern Bering Sea

    NASA Astrophysics Data System (ADS)

    Richar, Jonathan I.; Kruse, Gordon H.; Curchitser, Enrique; Hermann, Albert J.

    2015-11-01

    The eastern Bering Sea (EBS) population of Tanner crab (Chionoecetes bairdi) has exhibited high variability in recruitment to the commercially exploited stock since the late 1970s. Concurrently, apparent shifts in crab distribution have also been observed. Larval advection patterns and associated local retention offer a potential mechanism for these observations. The Regional Ocean Modeling System (ROMS) was used to simulate larval Tanner crab advection patterns over 1978-2004 based on larval hatching sites inferred from the distributions of reproductive females sampled during annual National Marine Fisheries Service trawl surveys. Connectivity among EBS subregions was examined by comparing start and end float locations after 60 days of simulated drift. High levels of retention (>50% of floats) were observed in the majority of source subregions, and contributed significantly to the total number of endpoints in each region. Patterns in advection and resultant interregional connectivity were variable, with strongest sustained connectivity occurring along shelf, within individual domains. Increased settlement potential in the outer domain and southern middle domain after 1990 is consistent with an observed geographic shift in fishery productivity. Apparent reliance of Bristol Bay on local larval retention validates recent spatial fishery management to conserve this area as a subpopulation.

  10. Materials and methods for the preparation of nanocomposites

    DOEpatents

    Talapin, Dmitri V.; Kovalenko, Maksym V.; Lee, Jong-Soo; Jiang, Chengyang

    2016-05-24

    Disclosed herein is an isolable colloidal particle comprising a nanoparticle and an inorganic capping agent bound to the surface of the nanoparticle, a solution of the same, a method for making the same from a biphasic solvent mixture, and the formation of structures and solids from the isolable colloidal particle. The process can yield photovoltaic cells, piezoelectric crystals, thermoelectric layers, optoelectronic layers, light emitting diodes, ferroelectric layers, thin film transistors, floating gate memory devices, imaging devices, phase change layers, and sensor devices.

  11. Nonvolatile programmable neural network synaptic array

    NASA Technical Reports Server (NTRS)

    Tawel, Raoul (Inventor)

    1994-01-01

    A floating-gate metal oxide semiconductor (MOS) transistor is implemented for use as a nonvolatile analog storage element of a synaptic cell used to implement an array of processing synaptic cells. These cells are based on a four-quadrant analog multiplier requiring both X and Y differential inputs, where one Y input is UV programmable. These nonvolatile synaptic cells are disclosed fully connected in a 32 x 32 synaptic cell array using standard very large scale integration (VLSI) complementary MOS (CMOS) technology.

  12. SONOS Nonvolatile Memory Cell Programming Characteristics

    NASA Technical Reports Server (NTRS)

    MacLeod, Todd C.; Phillips, Thomas A.; Ho, Fat D.

    2010-01-01

    Silicon-oxide-nitride-oxide-silicon (SONOS) nonvolatile memory is gaining favor over conventional EEPROM FLASH memory technology. This paper characterizes the SONOS write operation using a nonquasi-static MOSFET model. This includes floating gate charge and voltage characteristics as well as tunneling current, voltage threshold and drain current characterization. The characterization of the SONOS memory cell predicted by the model closely agrees with experimental data obtained from actual SONOS memory cells. The tunnel current, drain current, threshold voltage and read drain current all closely agreed with empirical data.

  13. A Substrate Bias Effect on Recovery of the Threshold Voltage Shift of Amorphous Silicon Thin-Film Transistors

    NASA Astrophysics Data System (ADS)

    Han, Chang-Wook; Han, Min-Koo; Choi, Nack-Bong; Kim, Chang-Dong; Kim, Ki-Yong; Chung, In-Jae

    2007-07-01

    Hydrogenated amorphous silicon (a-Si:H) thin-film transistors (TFTs) were fabricated on a flexible stainless-steel (SS) substrate. The stability of the a-Si:H TFT is a key issue for active matrix organic light-emitting diodes (AMOLEDs). The drain current decreases because of the threshold voltage shift (Δ VTH) during OLED driving. A negative voltage at a floated gate can be induced by a negative substrate bias through a capacitor between the substrate and the gate electrode without additional circuits. The negative voltage biased at the SS substrate can recover Δ VTH and reduced drain current of the driving TFT. The VTH of the TFT increased by 2.3 V under a gate bias of +15 V and a drain bias of +15 V at 65 °C applied for 3,500 s. The VTH decreased by -2.3 V and the drain current recovered 97% of its initial value under a substrate bias of -23 V at 65 °C applied for 3,500 s.

  14. Do submesoscale frontal processes ventilate the oxygen minimum zone off Peru?

    NASA Astrophysics Data System (ADS)

    Thomsen, S.; Kanzow, T.; Colas, F.; Echevin, V.; Krahmann, G.; Engel, A.

    2016-02-01

    The Peruvian upwelling region shows pronounced near-surface submesoscale variability including filaments and sharp density fronts. Submesoscale frontal processes can drive large vertical velocities and enhance vertical tracer fluxes in the upper ocean. The associated high temporal and spatial variability poses a large challenge to observational approaches targeting these processes. In this study the role of submesoscale processes for the ventilation of the near-coastal oxygen minimum zone off Peru is investigated. We use satellite based sea surface temperature measurements and multiple high-resolution glider observations of temperature, salinity, oxygen and chlorophyll fluorescence carried out in January and February 2013 off Peru near 14°S during active upwelling. Additionally, high-resolution regional ocean circulation model outputs (ROMS) outputs are analysed. At the beginning of our observational survey a previously upwelled, productive and highly oxygenated water body is found in the mixed layer. Subsequently, a cold filament forms and the waters are moved offshore. After the decay of the filament and the relaxation of the upwelling front, the oxygen enriched surface water is found in the previously less oxygenated thermocline suggesting the occurrence of frontal subduction. A numerical model simulation is used to analyse the evolution of Lagrangian numerical floats in several upwelling filaments, whose vertical structure and hydrographic properties agree well with the observations. The floats trajectories support our interpretation that the subduction of previously upwelled water occurs in filaments off Peru. We find that 40 - 60 % of the floats seeded in the newly upwelled water is subducted within a time period of 5 days. This hightlights the importance of this process in ventilating the oxycline off Peru.

  15. A Fully Reconfigurable Low-Noise Biopotential Sensing Amplifier With 1.96 Noise Efficiency Factor.

    PubMed

    Tzu-Yun Wang; Min-Rui Lai; Twigg, Christopher M; Sheng-Yu Peng

    2014-06-01

    A fully reconfigurable biopotential sensing amplifier utilizing floating-gate transistors is presented in this paper. By using the complementary differential pairs along with the current reuse technique, the theoretical limit for the noise efficiency factor of the proposed amplifier is below 1.5. Without consuming any extra power, floating-gate transistors are employed to program the low-frequency cutoff corner of the amplifier and to implement the common-mode feedback. A concept proving prototype chip was designed and fabricated in a 0.35 μm CMOS process occupying 0.17 mm (2) silicon area. With a supply voltage of 2.5 V, the measured midband gain is 40.7 dB and the measured input-referred noise is 2.8 μVrms. The chip was tested under several configurations with the amplifier bandwidth being programmed to 100 Hz, 1 kHz , and 10 kHz. The measured noise efficiency factors in these bandwidth settings are 1.96, 2.01, and 2.25, respectively, which are among the best numbers reported to date. The measured common-mode rejection and the supply rejection are above 70 dB . When the bandwidth is configured to be 10 kHz, the dynamic range measured at 1 kHz is 60 dB with total harmonic distortion less than 0.1%. The proposed amplifier is also demonstrated by recording electromyography (EMG), electrocardiography (ECG), electrooculography (EOG), and electroencephalography (EEG) signals from human bodies.

  16. High-Performance Flexible Organic Nano-Floating Gate Memory Devices Functionalized with Cobalt Ferrite Nanoparticles.

    PubMed

    Jung, Ji Hyung; Kim, Sunghwan; Kim, Hyeonjung; Park, Jongnam; Oh, Joon Hak

    2015-10-07

    Nano-floating gate memory (NFGM) devices are transistor-type memory devices that use nanostructured materials as charge trap sites. They have recently attracted a great deal of attention due to their excellent performance, capability for multilevel programming, and suitability as platforms for integrated circuits. Herein, novel NFGM devices have been fabricated using semiconducting cobalt ferrite (CoFe2O4) nanoparticles (NPs) as charge trap sites and pentacene as a p-type semiconductor. Monodisperse CoFe2O4 NPs with different diameters have been synthesized by thermal decomposition and embedded in NFGM devices. The particle size effects on the memory performance have been investigated in terms of energy levels and particle-particle interactions. CoFe2O4 NP-based memory devices exhibit a large memory window (≈73.84 V), a high read current on/off ratio (read I(on)/I(off)) of ≈2.98 × 10(3), and excellent data retention. Fast switching behaviors are observed due to the exceptional charge trapping/release capability of CoFe2O4 NPs surrounded by the oleate layer, which acts as an alternative tunneling dielectric layer and simplifies the device fabrication process. Furthermore, the NFGM devices show excellent thermal stability, and flexible memory devices fabricated on plastic substrates exhibit remarkable mechanical and electrical stability. This study demonstrates a viable means of fabricating highly flexible, high-performance organic memory devices. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Mechanistic analysis of temperature-dependent current conduction through thin tunnel oxide in n+-polySi/SiO2/n+-Si structures

    NASA Astrophysics Data System (ADS)

    Samanta, Piyas

    2017-09-01

    We present a detailed investigation on temperature-dependent current conduction through thin tunnel oxides grown on degenerately doped n-type silicon (n+-Si) under positive bias ( VG ) on heavily doped n-type polycrystalline silicon (n+-polySi) gate in metal-oxide-semiconductor devices. The leakage current measured between 298 and 573 K and at oxide fields ranging from 6 to 10 MV/cm is primarily attributed to Poole-Frenkel (PF) emission of trapped electrons from the neutral electron traps located in the silicon dioxide (SiO2) band gap in addition to Fowler-Nordheim (FN) tunneling of electrons from n+-Si acting as the drain node in FLOating gate Tunnel OXide Electrically Erasable Programmable Read-Only Memory devices. Process-induced neutral electron traps are located at 0.18 eV and 0.9 eV below the SiO2 conduction band. Throughout the temperature range studied here, PF emission current IPF dominates FN electron tunneling current IFN at oxide electric fields Eox between 6 and 10 MV/cm. A physics based new analytical formula has been developed for FN tunneling of electrons from the accumulation layer of degenerate semiconductors at a wide range of temperatures incorporating the image force barrier rounding effect. FN tunneling has been formulated in the framework of Wentzel-Kramers-Brilloiun taking into account the correction factor due to abrupt variation of the energy barrier at the cathode/oxide interface. The effect of interfacial and near-interfacial trapped-oxide charges on FN tunneling has also been investigated in detail at positive VG . The mechanism of leakage current conduction through SiO2 films plays a crucial role in simulation of time-dependent dielectric breakdown of the memory devices and to precisely predict the normal operating field or applied floating gate (FG) voltage for lifetime projection of the devices. In addition, we present theoretical results showing the effect of drain doping concentration on the FG leakage current.

  18. The fault-tree compiler

    NASA Technical Reports Server (NTRS)

    Martensen, Anna L.; Butler, Ricky W.

    1987-01-01

    The Fault Tree Compiler Program is a new reliability tool used to predict the top event probability for a fault tree. Five different gate types are allowed in the fault tree: AND, OR, EXCLUSIVE OR, INVERT, and M OF N gates. The high level input language is easy to understand and use when describing the system tree. In addition, the use of the hierarchical fault tree capability can simplify the tree description and decrease program execution time. The current solution technique provides an answer precise (within the limits of double precision floating point arithmetic) to the five digits in the answer. The user may vary one failure rate or failure probability over a range of values and plot the results for sensitivity analyses. The solution technique is implemented in FORTRAN; the remaining program code is implemented in Pascal. The program is written to run on a Digital Corporation VAX with the VMS operation system.

  19. Cryogenic measurements of aerojet GaAs n-JFETs

    NASA Technical Reports Server (NTRS)

    Goebel, John H.; Weber, Theodore T.

    1993-01-01

    The spectral noise characteristics of Aerojet gallium arsenide (GaAs) junction field effect transistors (JFET's) have been investigated down to liquid-helium temperatures. Noise characterization was performed with the field effect transistor (FET) in the floating-gate mode, in the grounded-gate mode to determine the lowest noise readings possible, and with an extrinsic silicon photodetector at various detector bias voltages to determine optimum operating conditions. The measurements indicate that the Aerojet GaAs JFET is a quiet and stable device at liquid helium temperatures. Hence, it can be considered a readout line driver or infrared detector preamplifier as well as a host of other cryogenic applications. Its noise performance is superior to silicon (Si) metal oxide semiconductor field effect transistor (MOSFET's) operating at liquid helium temperatures, and is equal to the best Si n channel junction field effect transistor (n-JFET's) operating at 300 K.

  20. Performance of a multistep fluorescence-gated proportional counter for hard X-ray astronomy

    NASA Technical Reports Server (NTRS)

    Dietz, K. L.; Ramsey, B. D.; Weisskopf, M. C.

    1992-01-01

    Results from the first flight of our proportional counter in an imaging telescope led us to rebuild the detector. We have used a Penning gas mixture (xenon + 1 percent isobutylene) and introduced a preamplification region to improve the energy resolution. We have rebuilt the pressure vessel making novel use of molybdenum as the housing material in order to reduce the residual instrument background, particularly in the fluorescence-gated mode for which the detector design has been optimized. We have also increased the sensitive gas depth from 9 to 14 cm to further increase the sensitivity to both fluorescent pairs and conventional singles. Our calibrations have shown that the overall energy resolution of the detector has been enhanced by a factor of 2, and we predict that the sensitivity at float will increase by a factor of 3 in the 50-70 keV energy band.

  1. Active pixel sensor pixel having a photodetector whose output is coupled to an output transistor gate

    NASA Technical Reports Server (NTRS)

    Fossum, Eric R. (Inventor); Nakamura, Junichi (Inventor); Kemeny, Sabrina E. (Inventor)

    2005-01-01

    An imaging device formed as a monolithic complementary metal oxide semiconductor integrated circuit in an industry standard complementary metal oxide semiconductor process, the integrated circuit including a focal plane array of pixel cells, each one of the cells including a photogate overlying the substrate for accumulating photo-generated charge in an underlying portion of the substrate and a charge coupled device section formed on the substrate adjacent the photogate having a sensing node and at least one charge coupled device stage for transferring charge from the underlying portion of the substrate to the sensing node. There is also a readout circuit, part of which can be disposed at the bottom of each column of cells and be common to all the cells in the column. A Simple Floating Gate (SFG) pixel structure could also be employed in the imager to provide a non-destructive readout and smaller pixel sizes.

  2. The Fault Tree Compiler (FTC): Program and mathematics

    NASA Technical Reports Server (NTRS)

    Butler, Ricky W.; Martensen, Anna L.

    1989-01-01

    The Fault Tree Compiler Program is a new reliability tool used to predict the top-event probability for a fault tree. Five different gate types are allowed in the fault tree: AND, OR, EXCLUSIVE OR, INVERT, AND m OF n gates. The high-level input language is easy to understand and use when describing the system tree. In addition, the use of the hierarchical fault tree capability can simplify the tree description and decrease program execution time. The current solution technique provides an answer precisely (within the limits of double precision floating point arithmetic) within a user specified number of digits accuracy. The user may vary one failure rate or failure probability over a range of values and plot the results for sensitivity analyses. The solution technique is implemented in FORTRAN; the remaining program code is implemented in Pascal. The program is written to run on a Digital Equipment Corporation (DEC) VAX computer with the VMS operation system.

  3. Potential utility of three-dimensional temperature and salinity fields estimated from satellite altimetry and Argo data for improving mesoscale reproducibility in regional ocean modeling

    NASA Astrophysics Data System (ADS)

    Kanki, R.; Uchiyama, Y.; Miyazaki, D.; Takano, A.; Miyazawa, Y.; Yamazaki, H.

    2014-12-01

    Mesoscale oceanic structure and variability are required to be reproduced as accurately as possible in realistic regional ocean modeling. Uchiyama et al. (2012) demonstrated with a submesoscale eddy-resolving JCOPE2-ROMS downscaling oceanic modeling system that the mesoscale reproducibility of the Kuroshio meandering along Japan is significantly improved by introducing a simple restoration to data which we call "TS nudging" (a.k.a. robust diagnosis) where the prognostic temperature and salinity fields are weakly nudged four-dimensionally towards the assimilative JCOPE2 reanalysis (Miyazawa et al., 2009). However, there is not always a reliable reanalysis for oceanic downscaling in an arbitrary region and at an arbitrary time, and therefore alternative dataset should be prepared. Takano et al. (2009) proposed an empirical method to estimate mesoscale 3-D thermal structure from the near real-time AVISO altimetry data along with the ARGO float data based on the two-layer model of Goni et al. (1996). In the present study, we consider the TS data derived from this method as a candidate. We thus conduct a synoptic forward modeling of the Kuroshio using the JCOPE2-ROMS downscaling system to explore potential utility of this empirical TS dataset (hereinafter TUM-TS) by carrying out two runs with the T-S nudging towards 1) the JCOPE2-TS and 2) TUM-TS fields. An example of the comparison between the two ROMS test runs is shown in the attached figure showing the annually averaged surface EKE. Both of TUM-TS and JCOPE2-TS are found to help reproducing the mesoscale variance of the Koroshio and its extension as well as its mean paths, surface KE and EKE reasonably well. Therefore, the AVISO-ARGO derived empirical 3-D TS estimation is potentially exploitable for the dataset to conduct the T-S nudging to reproduce mesoscale oceanic structure.

  4. Total Ionizing Dose Influence on the Single Event Effect Sensitivity in Samsung 8Gb NAND Flash Memories

    NASA Astrophysics Data System (ADS)

    Edmonds, Larry D.; Irom, Farokh; Allen, Gregory R.

    2017-08-01

    A recent model provides risk estimates for the deprogramming of initially programmed floating gates via prompt charge loss produced by an ionizing radiation environment. The environment can be a mixture of electrons, protons, and heavy ions. The model requires several input parameters. This paper extends the model to include TID effects in the control circuitry by including one additional parameter. Parameters intended to produce conservative risk estimates for the Samsung 8 Gb SLC NAND flash memory are given, subject to some qualifications.

  5. Effects of dc bias on the kinetics and electrical properties of silicon dioxide grown in an electron cyclotron resonance plasma

    NASA Astrophysics Data System (ADS)

    Carl, D. A.; Hess, D. W.; Lieberman, M. A.; Nguyen, T. D.; Gronsky, R.

    1991-09-01

    Thin (3-300-nm) oxides were grown on single-crystal silicon substrates at temperatures from 523 to 673 K in a low-pressure electron cyclotron resonance (ECR) oxygen plasma. Oxides were grown under floating, anodic or cathodic bias conditions, although only the oxides grown under floating or anodic bias conditions are acceptable for use as gate dielectrics in metal-oxide-semiconductor technology. Oxide thickness uniformity as measured by ellipsometry decreased with increasing oxidation time for all bias conditions. Oxidation kinetics under anodic conditions can be explained by negatively charged atomic oxygen, O-, transport limited growth. Constant current anodizations yielded three regions of growth: (1) a concentration gradient dominated regime for oxides thinner than 10 nm, (2) a field dominated regime with ohmic charged oxidant transport for oxide thickness in the range of 10 nm to approximately 100 nm, and (3) a space-charge limited regime for films thicker than approximately 100 nm. The relationship between oxide thickness (xox), overall potential drop (Vox) and ion current (ji) in the space-charge limited transport region was of the form: ji ∝ V2ox/x3ox. Transmission electron microscopy analysis of 5-60-nm-thick anodized films indicated that the silicon-silicon dioxide interface was indistinguishable from that of thermal oxides grown at 1123 K. High-frequency capacitance-voltage (C-V) and ramped bias current-voltage (I-V) studies performed on 5.4-30-nm gate thickness capacitors indicated that the as-grown ECR films had high levels of fixed oxide charge (≳1011 cm-2) and interface traps (≳1012 cm-2 eV-1). The fixed charge level could be reduced to ≊4×1010 cm-2 by a 20 min polysilicon gate activation anneal at 1123 K in nitrogen; the interface trap density at mid-band gap decreased to ≊(1-2)×1011 cm-2 eV-1 after this process. The mean breakdown strength for anodic oxides grown under optimum conditions was 10.87±0.83 MV cm-1. Electrical properties of the 5.4-8-nm gates compared well with thicker films and control dry thermal oxides of similar thicknesses.

  6. A Real-Time Marker-Based Visual Sensor Based on a FPGA and a Soft Core Processor

    PubMed Central

    Tayara, Hilal; Ham, Woonchul; Chong, Kil To

    2016-01-01

    This paper introduces a real-time marker-based visual sensor architecture for mobile robot localization and navigation. A hardware acceleration architecture for post video processing system was implemented on a field-programmable gate array (FPGA). The pose calculation algorithm was implemented in a System on Chip (SoC) with an Altera Nios II soft-core processor. For every frame, single pass image segmentation and Feature Accelerated Segment Test (FAST) corner detection were used for extracting the predefined markers with known geometries in FPGA. Coplanar PosIT algorithm was implemented on the Nios II soft-core processor supplied with floating point hardware for accelerating floating point operations. Trigonometric functions have been approximated using Taylor series and cubic approximation using Lagrange polynomials. Inverse square root method has been implemented for approximating square root computations. Real time results have been achieved and pixel streams have been processed on the fly without any need to buffer the input frame for further implementation. PMID:27983714

  7. Evaluation of a “Field Cage” for Electric Field Control in GaN-Based HEMTs That Extends the Scalability of Breakdown Into the kV Regime

    DOE PAGES

    Tierney, Brian D.; Choi, Sukwon; DasGupta, Sandeepan; ...

    2017-08-16

    A distributed impedance “field cage” structure is proposed and evaluated for electric field control in GaN-based, lateral high electron mobility transistors (HEMTs) operating as kilovolt-range power devices. In this structure, a resistive voltage divider is used to control the electric field throughout the active region. The structure complements earlier proposals utilizing floating field plates that did not employ resistively connected elements. Transient results, not previously reported for field plate schemes using either floating or resistively connected field plates, are presented for ramps of dV ds /dt = 100 V/ns. For both DC and transient results, the voltage between the gatemore » and drain is laterally distributed, ensuring the electric field profile between the gate and drain remains below the critical breakdown field as the source-to-drain voltage is increased. Our scheme indicates promise for achieving breakdown voltage scalability to a few kV.« less

  8. A Real-Time Marker-Based Visual Sensor Based on a FPGA and a Soft Core Processor.

    PubMed

    Tayara, Hilal; Ham, Woonchul; Chong, Kil To

    2016-12-15

    This paper introduces a real-time marker-based visual sensor architecture for mobile robot localization and navigation. A hardware acceleration architecture for post video processing system was implemented on a field-programmable gate array (FPGA). The pose calculation algorithm was implemented in a System on Chip (SoC) with an Altera Nios II soft-core processor. For every frame, single pass image segmentation and Feature Accelerated Segment Test (FAST) corner detection were used for extracting the predefined markers with known geometries in FPGA. Coplanar PosIT algorithm was implemented on the Nios II soft-core processor supplied with floating point hardware for accelerating floating point operations. Trigonometric functions have been approximated using Taylor series and cubic approximation using Lagrange polynomials. Inverse square root method has been implemented for approximating square root computations. Real time results have been achieved and pixel streams have been processed on the fly without any need to buffer the input frame for further implementation.

  9. Evaluation of a “Field Cage” for Electric Field Control in GaN-Based HEMTs That Extends the Scalability of Breakdown Into the kV Regime

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tierney, Brian D.; Choi, Sukwon; DasGupta, Sandeepan

    A distributed impedance “field cage” structure is proposed and evaluated for electric field control in GaN-based, lateral high electron mobility transistors (HEMTs) operating as kilovolt-range power devices. In this structure, a resistive voltage divider is used to control the electric field throughout the active region. The structure complements earlier proposals utilizing floating field plates that did not employ resistively connected elements. Transient results, not previously reported for field plate schemes using either floating or resistively connected field plates, are presented for ramps of dV ds /dt = 100 V/ns. For both DC and transient results, the voltage between the gatemore » and drain is laterally distributed, ensuring the electric field profile between the gate and drain remains below the critical breakdown field as the source-to-drain voltage is increased. Our scheme indicates promise for achieving breakdown voltage scalability to a few kV.« less

  10. Depletion type floating gate p-channel MOS transistor for recording action potentials generated by cultured neurons.

    PubMed

    Cohen, Ariel; Spira, Micha E; Yitshaik, Shlomo; Borghs, Gustaaf; Shwartzglass, Ofer; Shappir, Joseph

    2004-07-15

    We report the realization of electrical coupling between neurons and depletion type floating gate (FG) p-channel MOS transistors. The devices were realized in a shortened 0.5 microm CMOS technology. Increased boron implant dose was used to form the depletion type devices. Post-CMOS processing steps were added to expose the devices sensing area. The neurons are coupled to the polycrystalline silicon (PS) FG through 420A thermal oxide in an area which is located over the thick field oxide away from the transistor. The combination of coupling area pad having a diameter of 10 or 15 microm and sensing transistor with W/L of 50/0.5 microm results in capacitive coupling ratio of the neuron signal of about 0.5 together with relatively large transistor transconductance. The combination of the FG structure with a depletion type device, leads to the following advantages. (a) No need for dc bias between the solution in which the neurons are cultured and the transistor with expected consequences to the neuron as well as the silicon die durability. (b) The sensing area of the neuron activity is separated from the active area of the transistor. Thus, it is possible to design the sensing area and the channel area separately. (c) The channel area, which is the most sensitive part of the transistor, can be insulated and shielded from the ionic solution in which the neurons are cultured. (d) There is an option to add a switching transistor to the FG and use the FG also for the neuron stimulation.

  11. CD-ROM-aided Databases

    NASA Astrophysics Data System (ADS)

    Shimbori, Susumu

    CD-ROM has recently attracted remarkable attentions as a new information media. In this feature the following points concerning CD-ROM are described: (1) Development of CD-ROM from audio CD, (2)advantages and character of CD-ROM compared with printed or online media, (3)CD-ROM specification by Philips-Sony, (4)hardware and system construction with CD-ROM, and (5)production processes of CD-ROM.

  12. Modeling of Sonos Memory Cell Erase Cycle

    NASA Technical Reports Server (NTRS)

    Phillips, Thomas A.; MacLeond, Todd C.; Ho, Fat D.

    2010-01-01

    Silicon-oxide-nitride-oxide-silicon (SONOS) nonvolatile semiconductor memories (NVSMS) have many advantages. These memories are electrically erasable programmable read-only memories (EEPROMs). They utilize low programming voltages, endure extended erase/write cycles, are inherently resistant to radiation, and are compatible with high-density scaled CMOS for low power, portable electronics. The SONOS memory cell erase cycle was investigated using a nonquasi-static (NQS) MOSFET model. The SONOS floating gate charge and voltage, tunneling current, threshold voltage, and drain current were characterized during an erase cycle. Comparisons were made between the model predictions and experimental device data.

  13. High mobility AlGaN/GaN devices for β--dosimetry

    NASA Astrophysics Data System (ADS)

    Schmid, Martin; Howgate, John; Ruehm, Werner; Thalhammer, Stefan

    2016-05-01

    There is a high demand in modern medical applications for dosimetry sensors with a small footprint allowing for unobtrusive or high spatial resolution detectors. To this end we characterize the sensoric response of radiation resistant high mobility AlGaN/GaN semiconductor devices when exposed to β--emitters. The samples were operated as a floating gate transistor, without a field effect gate electrode, thus excluding any spurious effects from β--particle interactions with a metallic surface covering. We demonstrate that the source-drain current is modulated in dependence on the kinetic energy of the incident β--particles. Here, the signal is shown to have a linear dependence on the absorbed energy calculated from Monte Carlo simulations. Additionally, a stable and reproducible sensor performance as a β--dose monitor is shown for individual radioisotopes. Our experimental findings and the characteristics of the AlGaN/GaN high mobility layered devices indicate their potential for future applications where small sensor size is necessary, like for instance brachytherapy.

  14. Nanocrystal-mediated charge screening effects in nanowire field-effect transistors

    NASA Astrophysics Data System (ADS)

    Yoon, C. J.; Yeom, D. H.; Jeong, D. Y.; Lee, M. G.; Moon, B. M.; Kim, S. S.; Choi, C. Y.; Koo, S. M.

    2009-03-01

    ZnO nanowire field-effect transistors having an omega-shaped floating gate (OSFG) have been successfully fabricated by directly coating CdTe nanocrystals (˜6±2.5 nm) at room temperature, and compared to simultaneously prepared control devices without nanocrystals. Herein, we demonstrate that channel punchthrough may occur when the depletion from the OSFG takes place due to the trapped charges in the nanocrystals. Electrical measurements on the OSFG nanowire devices showed static-induction transistorlike behavior in the drain output IDS-VDS characteristics and a hysteresis window as large as ˜3.1 V in the gate transfer IDS-VGS characteristics. This behavior is ascribed to the presence of the CdTe nanocrystals, and is indicative of the trapping and emission of electrons in the nanocrystals. The numerical simulations clearly show qualitatively the same characteristics as the experimental data and confirm the effect, showing that the change in the potential distribution across the channel, induced by both the wrapping-around gate and the drain, affects the transport characteristics of the device. The cross-sectional energy band and potential profile of the OSFG channel corresponding to the "programed (noncharged)" and "erased (charged)" operations for the device are also discussed on the basis of the numerical capacitance-voltage simulations.

  15. FG Width Scalability of the 3-D Vertical FG NAND Using the Sidewall Control Gate (SCG)

    NASA Astrophysics Data System (ADS)

    Seo, Moon-Sik; Endoh, Tetsuo

    Recently, the 3-D vertical Floating Gate (FG) type NAND cell arrays with the Sidewall Control Gate (SCG), such as ESCG, DC-SF and S-SCG, are receiving attention to overcome the reliability issues of Charge Trap (CT) type device. Using this novel cell structure, highly reliable flash cell operations were successfully implemented without interference effect on the FG type cell. However, the 3-D vertical FG type cell has large cell size by about 60% for the cylindrical FG structure. In this point of view, we intensively investigate the scalability of the FG width of the 3-D vertical FG NAND cells. In case of the planar FG type NAND cell, the FG height cannot be scaled down due to the necessity of obtaining sufficient coupling ratio and high program speed. In contrast, for the 3-D vertical FG NAND with SCG, the FG is formed cylindrically, which is fully covered with surrounded CG, and very high CG coupling ratio can be achieved. As results, the scaling of FG width of the 3-D vertical FG NAND cell with S-SCG can be successfully demonstrated at 10nm regime, which is almost the same as the CT layer of recent BE-SONOS NAND.

  16. An adaptable neuromorphic model of orientation selectivity based on floating gate dynamics

    PubMed Central

    Gupta, Priti; Markan, C. M.

    2014-01-01

    The biggest challenge that the neuromorphic community faces today is to build systems that can be considered truly cognitive. Adaptation and self-organization are the two basic principles that underlie any cognitive function that the brain performs. If we can replicate this behavior in hardware, we move a step closer to our goal of having cognitive neuromorphic systems. Adaptive feature selectivity is a mechanism by which nature optimizes resources so as to have greater acuity for more abundant features. Developing neuromorphic feature maps can help design generic machines that can emulate this adaptive behavior. Most neuromorphic models that have attempted to build self-organizing systems, follow the approach of modeling abstract theoretical frameworks in hardware. While this is good from a modeling and analysis perspective, it may not lead to the most efficient hardware. On the other hand, exploiting hardware dynamics to build adaptive systems rather than forcing the hardware to behave like mathematical equations, seems to be a more robust methodology when it comes to developing actual hardware for real world applications. In this paper we use a novel time-staggered Winner Take All circuit, that exploits the adaptation dynamics of floating gate transistors, to model an adaptive cortical cell that demonstrates Orientation Selectivity, a well-known biological phenomenon observed in the visual cortex. The cell performs competitive learning, refining its weights in response to input patterns resembling different oriented bars, becoming selective to a particular oriented pattern. Different analysis performed on the cell such as orientation tuning, application of abnormal inputs, response to spatial frequency and periodic patterns reveal close similarity between our cell and its biological counterpart. Embedded in a RC grid, these cells interact diffusively exhibiting cluster formation, making way for adaptively building orientation selective maps in silicon. PMID:24765062

  17. Design of a Programmable Gain, Temperature Compensated Current-Input Current-Output CMOS Logarithmic Amplifier.

    PubMed

    Ming Gu; Chakrabartty, Shantanu

    2014-06-01

    This paper presents the design of a programmable gain, temperature compensated, current-mode CMOS logarithmic amplifier that can be used for biomedical signal processing. Unlike conventional logarithmic amplifiers that use a transimpedance technique to generate a voltage signal as a logarithmic function of the input current, the proposed approach directly produces a current output as a logarithmic function of the input current. Also, unlike a conventional transimpedance amplifier the gain of the proposed logarithmic amplifier can be programmed using floating-gate trimming circuits. The synthesis of the proposed circuit is based on the Hart's extended translinear principle which involves embedding a floating-voltage source and a linear resistive element within a translinear loop. Temperature compensation is then achieved using a translinear-based resistive cancelation technique. Measured results from prototypes fabricated in a 0.5 μm CMOS process show that the amplifier has an input dynamic range of 120 dB and a temperature sensitivity of 230 ppm/°C (27 °C- 57°C), while consuming less than 100 nW of power.

  18. Development of a three-dimensional variational data assimilation system for the Seto Island Sea, Japan

    NASA Astrophysics Data System (ADS)

    Kurosawa, K.; Uchiyama, Y.

    2016-12-01

    By optimally combined ocean models with observation data, numerical oceanic reanalysis and forecast systems allow us to predict the ocean more precisely. In general, data assimilation is exploited to prepare the initial condition for the forecast. This technique has widely been employed in atmospheric prediction, whereas oceanic prediction lags behind weather forecast. Accurate oceanic prediction systems have been demanded for operational purposes such as for fisheries, vessel navigation, marine construction, offshore platform management, marine monitoring, etc. In particular, in crowded harbors and estuaries including the Seto Inland Sea (SIS), Japan, data assimilation has seldom been adapted because data from satellites and Argo floats essential to successful oceanic predictions is desperately limited. In addition, although static data assimilation, typically three-dimensional variational data assimilation (3DVAR), is computationally cheap and statistically optimal, but is not physically balanced. For instance, 3DVAR is known to modify velocity and density fields merely mathematically, yet it does not adequately consider quasi-geostrophic balance, which is generally true in most cases. In the present study, we develop a 3DVAR system for Regional Oceanic Modeling Systems (ROMS) and apply to the high-resolution SIS model in a double nested configuration (Kosako et al., 2015). The SIS is the largest estuary in Japan with a number of autonomous in-situ monitoring of vertical profiles of temperature and salinity, tens of tidal gages, along with continuous surface current measurement using HF radars. We first present a theoretical framework of the 3DVAR algorithm by considering geostrophic and thermal-wind balance to find plausible relationships among physical variables to avoid undesirable modifications. Subsequently, the developed 3DVAR is coupled with the SIS ROMS model to compare the model outcomes against some observation data. The 3DVAR ROMS model for the SIS performs much better than the SIS model without assimilation and demonstrates good model skills with reproducing quite complex flows in the SIS because of its complicated topography with more than 3,000 islands in there. Furthermore we will share technical difficulties encountered during the experiment.

  19. Differentiation of Swine iPSC into Rod Photoreceptors and Their Integration into the Retina

    PubMed Central

    Zhou, Liang; Wang, Wei; Liu, Yongqing; de Castro, Juan Fernandez; Ezashi, Toshihiko; Telugu, Bhanu Prakash V.L.; Roberts, R. Michael; Kaplan, Henry J.; Dean, Douglas C.

    2014-01-01

    Absence of a regenerative pathway for damaged retina following injury or disease has led to experiments utilizing stem cell transplantation for retinal repair, and encouraging results have been obtained in rodents. The swine eye is a closer anatomical and physiological match to the human eye, but embryonic stem cells have not been isolated from pig, and photoreceptor differentiation has not been demonstrated with swine induced pluripotent stem cells (iPSC). Here, we subjected swine iPSC to a rod photoreceptor differentiation protocol consisting of floating culture as embryoid bodies followed by differentiation in adherent culture. Real time PCR and immunostaining of differentiated cells demonstrated loss of expression of the pluripotent genes POU5F1, NANOG and SOX2 and induction of rod photoreceptor genes RCVRN, NRL, RHO and ROM1. While these differentiated cells displayed neuronal morphology, culturing on a Matrigel substratum triggered a further morphological change resulting in concentration of RHO and ROM1 in outer segment-like projections resembling those on primary cultures of rod photoreceptors. The differentiated cells were transplanted into the subretinal space of pigs treated with iodoacetic acid to eliminate rod photoreceptors. Three weeks after transplantation, engrafted RHO+ cells were evident in the outer nuclear layer where photoreceptors normally reside. A portion of these transplanted cells had generated projections resembling outer segments. These results demonstrate that swine iPSC can differentiate into photoreceptors in culture and these cells can integrate into the damaged swine neural retina thus laying a foundation for future studies using the pig as a model for retinal stem cell transplantation. PMID:21491544

  20. Special Considerations for Networking Multimedia CD-ROM Titles.

    ERIC Educational Resources Information Center

    Wolfe, Janet L.

    1994-01-01

    Discusses issues to be considered when networking multimedia CD-ROMs. Topics addressed include CD-ROM networking software; license concerns; configurations for CD-ROM servers; data caching; SCSI devices; CD-ROM drives; workstation configurations, including minimum requirements for five popular CD-ROM titles; and system setup troubleshooting tips.…

  1. CD-ROM-aided Databases

    NASA Astrophysics Data System (ADS)

    Nagatsuka, Takashi

    This paper introduces the CD-ROM-aided products and their utilization in foreign countries, mainly in U.S.A. CD-ROM is being used in various fields recently. Author classified its products into four groups:1. CD-ROM that substitutes for printed matters such as encyclopedias and dictionaries (ex. Grolier's Electronic Encyclopedia), 2. CD-ROM that substitutes for online databases (ex. Disclosure, Medline), 3. CD-ROM that has some functions such as giving orders for books besides information retrieval (ex. Books in Print Plus), 4. CD-ROM that contains literatures including pictures and figures (ex. ADONIS). The future trends of CD-ROM utilization are also suggested.

  2. Exploring the use of Routine Outcome Monitoring in the treatment of patients with a psychotic disorder.

    PubMed

    Tasma, M; Liemburg, E J; Knegtering, H; Delespaul, P A E G; Boonstra, A; Castelein, S

    2017-05-01

    Routine Outcome Monitoring (ROM) has become part of the treatment process in mental health care. However, studies have indicated that few clinicians in psychiatry use the outcome of ROM in their daily work. The aim of this study was to explore the degree of ROM use in clinical practice as well as the explanatory factors of this use. In the Northern Netherlands, a ROM-protocol (ROM-Phamous) for patients with a psychotic disorder has been implemented. To establish the degree of ROM-Phamous use in clinical practice, the ROM results of patients (n=204) were compared to the treatment goals formulated in their treatment plans. To investigate factors that might influence ROM use, clinicians (n=32) were asked to fill out a questionnaire about ROM-Phamous. Care domains that were problematic according to the ROM-Phamous results were mentioned in the treatment plan in 28% of cases on average (range 5-45%). The use of ROM-Phamous in the treatment process varies considerably among clinicians. Most of the clinicians find ROM-Phamous both useful and important for good clinical practice. In contrast, the perceived ease-of-use is low and most clinicians report insufficient time to use ROM-Phamous. More frequent ROM use should be facilitated in clinicians. This could be achieved by improving the fit with clinical routines and the ease-of-use of ROM systems. It is important for all stakeholders to invest in integrating ROM in clinical practice. Eventually, this might improve the diagnostics and treatment of patients in mental health care. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  3. Injection by hydrostatic pressure in conjunction with electrokinetic force on a microfluidic chip.

    PubMed

    Gai, Hongwei; Yu, Linfen; Dai, Zhongpeng; Ma, Yinfa; Lin, Bingcheng

    2004-06-01

    A simple method was developed for injecting a sample on a cross-form microfluidic chip by means of hydrostatic pressure combined with electrokinetic forces. The hydrostatic pressure was generated simply by adjusting the liquid level in different reservoirs without any additional driven equipment such as a pump. Two dispensing strategies using a floating injection and a gated injection, coupled with hydrostatic pressure loading, were tested. The fluorescence observation verified the feasibility of hydrostatic pressure loading in the separation of a mixture of fluorescein sodium salt and fluorescein isothiocyanate. This method was proved to be effective in leading cells to a separation channel for single cell analysis.

  4. Evaluation of Magnetoresistive RAM for Space Applications

    NASA Technical Reports Server (NTRS)

    Heidecker, Jason

    2014-01-01

    Magnetoresistive random-access memory (MRAM) is a non-volatile memory that exploits electronic spin, rather than charge, to store data. Instead of moving charge on and off a floating gate to alter the threshold voltage of a CMOS transistor (creating different bit states), MRAM uses magnetic fields to flip the polarization of a ferromagnetic material thus switching its resistance and bit state. These polarized states are immune to radiation-induced upset, thus making MRAM very attractive for space application. These magnetic memory elements also have infinite data retention and erase/program endurance. Presented here are results of reliability testing of two space-qualified MRAM products from Aeroflex and Honeywell.

  5. The Novice User and CD-ROM Database Services. ERIC Digest.

    ERIC Educational Resources Information Center

    Schamber, Linda

    This digest answers the following questions that beginning or novice users may have about CD-ROM (a compact disk with read-only memory) database services: (1) What is CD-ROM? (2) What databases are available? (3) Is CD-ROM difficult to use? (4) How much does CD-ROM cost? and (5) What is the future of CD-ROM? (15 references) (MES)

  6. CD-ROM in the age of internet

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conrad, B.; Depp, D.

    1994-12-31

    Networks are hot and CD-ROM is also hot, but how do they mix? CD-ROM is a relatively inexpensive medium for storing and delivering information, and increasingly, users are connected to networks. But the technologies have developed separately, and there are obstacles to their integration. Drawing on their experience networking CD-ROMs at Oak Ridge National Laboratory, the authors discuss CD-ROM`s strengths and weaknesses as a technology for delivering information to the desktop. CD-ROM networking solutions are LAN-based, not ``open systems.`` Despite this limitation, due to the large number of information resources available on CD-ROM and the relative ease of installing andmore » maintaining databases on CD-ROM, CD-ROMs remain an essential piece of the electronic information puzzle.« less

  7. Regression-based reduced-order models to predict transient thermal output for enhanced geothermal systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mudunuru, Maruti Kumar; Karra, Satish; Harp, Dylan Robert

    Reduced-order modeling is a promising approach, as many phenomena can be described by a few parameters/mechanisms. An advantage and attractive aspect of a reduced-order model is that it is computational inexpensive to evaluate when compared to running a high-fidelity numerical simulation. A reduced-order model takes couple of seconds to run on a laptop while a high-fidelity simulation may take couple of hours to run on a high-performance computing cluster. The goal of this paper is to assess the utility of regression-based reduced-order models (ROMs) developed from high-fidelity numerical simulations for predicting transient thermal power output for an enhanced geothermal reservoirmore » while explicitly accounting for uncertainties in the subsurface system and site-specific details. Numerical simulations are performed based on equally spaced values in the specified range of model parameters. Key sensitive parameters are then identified from these simulations, which are fracture zone permeability, well/skin factor, bottom hole pressure, and injection flow rate. We found the fracture zone permeability to be the most sensitive parameter. The fracture zone permeability along with time, are used to build regression-based ROMs for the thermal power output. The ROMs are trained and validated using detailed physics-based numerical simulations. Finally, predictions from the ROMs are then compared with field data. We propose three different ROMs with different levels of model parsimony, each describing key and essential features of the power production curves. The coefficients in the proposed regression-based ROMs are developed by minimizing a non-linear least-squares misfit function using the Levenberg–Marquardt algorithm. The misfit function is based on the difference between numerical simulation data and reduced-order model. ROM-1 is constructed based on polynomials up to fourth order. ROM-1 is able to accurately reproduce the power output of numerical simulations for low values of permeabilities and certain features of the field-scale data. ROM-2 is a model with more analytical functions consisting of polynomials up to order eight, exponential functions and smooth approximations of Heaviside functions, and accurately describes the field-data. At higher permeabilities, ROM-2 reproduces numerical results better than ROM-1, however, there is a considerable deviation from numerical results at low fracture zone permeabilities. ROM-3 consists of polynomials up to order ten, and is developed by taking the best aspects of ROM-1 and ROM-2. ROM-1 is relatively parsimonious than ROM-2 and ROM-3, while ROM-2 overfits the data. ROM-3 on the other hand, provides a middle ground for model parsimony. Based on R 2-values for training, validation, and prediction data sets we found that ROM-3 is better model than ROM-2 and ROM-1. For predicting thermal drawdown in EGS applications, where high fracture zone permeabilities (typically greater than 10 –15 m 2) are desired, ROM-2 and ROM-3 outperform ROM-1. As per computational time, all the ROMs are 10 4 times faster when compared to running a high-fidelity numerical simulation. In conclusion, this makes the proposed regression-based ROMs attractive for real-time EGS applications because they are fast and provide reasonably good predictions for thermal power output.« less

  8. Regression-based reduced-order models to predict transient thermal output for enhanced geothermal systems

    DOE PAGES

    Mudunuru, Maruti Kumar; Karra, Satish; Harp, Dylan Robert; ...

    2017-07-10

    Reduced-order modeling is a promising approach, as many phenomena can be described by a few parameters/mechanisms. An advantage and attractive aspect of a reduced-order model is that it is computational inexpensive to evaluate when compared to running a high-fidelity numerical simulation. A reduced-order model takes couple of seconds to run on a laptop while a high-fidelity simulation may take couple of hours to run on a high-performance computing cluster. The goal of this paper is to assess the utility of regression-based reduced-order models (ROMs) developed from high-fidelity numerical simulations for predicting transient thermal power output for an enhanced geothermal reservoirmore » while explicitly accounting for uncertainties in the subsurface system and site-specific details. Numerical simulations are performed based on equally spaced values in the specified range of model parameters. Key sensitive parameters are then identified from these simulations, which are fracture zone permeability, well/skin factor, bottom hole pressure, and injection flow rate. We found the fracture zone permeability to be the most sensitive parameter. The fracture zone permeability along with time, are used to build regression-based ROMs for the thermal power output. The ROMs are trained and validated using detailed physics-based numerical simulations. Finally, predictions from the ROMs are then compared with field data. We propose three different ROMs with different levels of model parsimony, each describing key and essential features of the power production curves. The coefficients in the proposed regression-based ROMs are developed by minimizing a non-linear least-squares misfit function using the Levenberg–Marquardt algorithm. The misfit function is based on the difference between numerical simulation data and reduced-order model. ROM-1 is constructed based on polynomials up to fourth order. ROM-1 is able to accurately reproduce the power output of numerical simulations for low values of permeabilities and certain features of the field-scale data. ROM-2 is a model with more analytical functions consisting of polynomials up to order eight, exponential functions and smooth approximations of Heaviside functions, and accurately describes the field-data. At higher permeabilities, ROM-2 reproduces numerical results better than ROM-1, however, there is a considerable deviation from numerical results at low fracture zone permeabilities. ROM-3 consists of polynomials up to order ten, and is developed by taking the best aspects of ROM-1 and ROM-2. ROM-1 is relatively parsimonious than ROM-2 and ROM-3, while ROM-2 overfits the data. ROM-3 on the other hand, provides a middle ground for model parsimony. Based on R 2-values for training, validation, and prediction data sets we found that ROM-3 is better model than ROM-2 and ROM-1. For predicting thermal drawdown in EGS applications, where high fracture zone permeabilities (typically greater than 10 –15 m 2) are desired, ROM-2 and ROM-3 outperform ROM-1. As per computational time, all the ROMs are 10 4 times faster when compared to running a high-fidelity numerical simulation. In conclusion, this makes the proposed regression-based ROMs attractive for real-time EGS applications because they are fast and provide reasonably good predictions for thermal power output.« less

  9. Functional analysis of rhomboid proteases during Toxoplasma invasion.

    PubMed

    Shen, Bang; Buguliskis, Jeffrey S; Lee, Tobie D; Sibley, L David

    2014-10-21

    Host cell invasion by Toxoplasma gondii and other apicomplexan parasites requires transmembrane adhesins that mediate binding to receptors on the substrate and host cell to facilitate motility and invasion. Rhomboid proteases (ROMs) are thought to cleave adhesins within their transmembrane segments, thus allowing the parasite to disengage from receptors and completely enter the host cell. To examine the specific roles of individual ROMs during invasion, we generated single, double, and triple knockouts for the three ROMs expressed in T. gondii tachyzoites. Analysis of these mutants demonstrated that ROM4 is the primary protease involved in adhesin processing and host cell invasion, whereas ROM1 or ROM5 plays negligible roles in these processes. Deletion of ROM4 blocked the shedding of adhesins such as MIC2 (microneme protein 2), causing them to accumulate on the surface of extracellular parasites. Increased surface adhesins led to nonproductive attachment, altered gliding motility, impaired moving junction formation, and reduced invasion efficiency. Despite the importance of ROM4 for efficient invasion, mutants lacking all three ROMs were viable and MIC2 was still efficiently removed from the surface of invaded mutant parasites, implying the existence of ROM-independent mechanisms for adhesin removal during invasion. Collectively, these results suggest that although ROM processing of adhesins is not absolutely essential, it is important for efficient host cell invasion by T. gondii. Importance: Apicomplexan parasites such as Toxoplasma gondii express surface proteins that bind host cell receptors to aid invasion. Many of these adhesins are subject to cleavage by rhomboid proteases (ROMs) within their transmembrane segments during invasion. Previous studies have demonstrated the importance of adhesin cleavage for parasite invasion and proposed that the ROMs responsible for processing would be essential for parasite survival. In T. gondii, ROM5 was thought to be the critical ROM for adhesin shedding due to its robust protease activity in vitro and posterior localization on the parasite surface. Here, we knocked out all three ROMs in T. gondii tachyzoites and found that ROM4, but not ROM5, was key for adhesin cleavage. However, none of the ROMs individually or in combination was essential for cell entry, further emphasizing that essential pathways such as invasion typically rely on redundant pathways to ensure survival. Copyright © 2014 Shen et al.

  10. Hip rotation range of motion in sitting and prone positions in healthy Japanese adults

    PubMed Central

    Han, Heonsoo; Kubo, Akira; Kurosawa, Kazuo; Maruichi, Shizuka; Maruyama, Hitoshi

    2015-01-01

    [Purpose] The aim of this study was to elucidate the difference in hip external and internal rotation ranges of motion (ROM) between the prone and sitting positions. [Subjects] The subjects included 151 students. [Methods] Hip rotational ROM was measured with the subjects in the prone and sitting positions. Two-way repeated measures analysis of variance (ANOVA) was used to analyze ipsilateral hip rotation ROM in the prone and sitting positions in males and females. The total ipsilateral hip rotation ROM was calculated by adding the measured values for external and internal rotations. [Results] Ipsilateral hip rotation ROM revealed significant differences between two positions for both left and right internal and external rotations. Hip rotation ROM was significantly higher in the prone position than in the sitting position. Hip rotation ROM significantly differed between the men and women. Hip external rotation ROM was significantly higher in both positions in men; conversely, hip internal rotation ROM was significantly higher in both positions in women. [Conclusion] Hip rotation ROM significantly differed between the sexes and between the sitting and prone positions. Total ipsilateral hip rotation ROM, total angle of external rotation, and total angle of internal rotation of the left and right hips greatly varied, suggesting that hip joint rotational ROM is widely distributed. PMID:25729186

  11. Increased Range of Motion Is Important for Functional Outcome and Satisfaction After Total Knee Arthroplasty in Asian Patients.

    PubMed

    Ha, Chul-Won; Park, Yong-Beom; Song, Young-Suk; Kim, Jun-Ho; Park, Yong-Geun

    2016-06-01

    Although range of motion (ROM) is considered as an important factor for good outcome after total knee arthroplasty (TKA), the association of the degree of ROM with functional outcome and patient satisfaction is debated. We, therefore, investigated whether increased ROM would affect functional outcome and patient satisfaction after TKA in Asian patients. We reviewed 630 patients who underwent primary TKA with minimum 2-year follow-up. Clinical outcomes were evaluated by Knee Society (KS) score, Western Ontario and McMaster Universities osteoarthritis index, and high-flexion knee score. Patient satisfaction was evaluated using a validated questionnaire. The association of ROM and change in ROM (cROM) with clinical outcomes and satisfaction were analyzed using partial correlation analysis and multiple median regression analysis. All functional scores showed significant correlation with postoperative ROM (r = 0.129, P = .001 in Knee Society score; r = -0.101, P = .012 in Western Ontario and McMaster Universities osteoarthritis index; r = 0.183, P < .001 in high-flexion knee score). cROM correlated with satisfaction (r = 0.192, P = .005). Postoperative ROM and cROM were revealed as predisposing factors affecting function outcome using multivariable regression analysis. cROM was found as a predisposing factor affecting satisfaction. Based on the results of this study, ROM positively associated with functional outcome and cROM positively associated with patient satisfaction after TKA. These findings suggest that increased ROM after TKA is an important factor for functional outcome and satisfaction in Asian patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Distributing the Wealth: Sliding CD-ROM into the Consumer Channel.

    ERIC Educational Resources Information Center

    Bowers, Richard A.

    1994-01-01

    Examines retail sales of CD-ROMs. Topics addressed include the current situation in CD-ROM retailing; channel distribution options; myths and realities of CD-ROM distribution; the distributor; affiliate labels; sales representatives; copublishers; distribution options; distributing resources; and recommendations for new CD-ROM publishers. (LRW)

  13. Constrained reduced-order models based on proper orthogonal decomposition

    DOE PAGES

    Reddy, Sohail R.; Freno, Brian Andrew; Cizmas, Paul G. A.; ...

    2017-04-09

    A novel approach is presented to constrain reduced-order models (ROM) based on proper orthogonal decomposition (POD). The Karush–Kuhn–Tucker (KKT) conditions were applied to the traditional reduced-order model to constrain the solution to user-defined bounds. The constrained reduced-order model (C-ROM) was applied and validated against the analytical solution to the first-order wave equation. C-ROM was also applied to the analysis of fluidized beds. Lastly, it was shown that the ROM and C-ROM produced accurate results and that C-ROM was less sensitive to error propagation through time than the ROM.

  14. Using the American alligator and a repeated-measures design to place constraints on in vivo shoulder joint range of motion in dinosaurs and other fossil archosaurs.

    PubMed

    Hutson, Joel D; Hutson, Kelda N

    2013-01-15

    Using the extant phylogenetic bracket of dinosaurs (crocodylians and birds), recent work has reported that elbow joint range of motion (ROM) studies of fossil dinosaur forearms may be providing conservative underestimates of fully fleshed in vivo ROM. As humeral ROM occupies a more central role in forelimb movements, the placement of quantitative constraints on shoulder joint ROM could improve fossil reconstructions. Here, we investigated whether soft tissues affect the more mobile shoulder joint in the same manner in which they affect elbow joint ROM in an extant archosaur. This test involved separately and repeatedly measuring humeral ROM in Alligator mississippiensis as soft tissues were dissected away in stages to bare bone. Our data show that the ROMs of humeral flexion and extension, as well as abduction and adduction, both show a statistically significant increase as flesh is removed, but then decrease when the bones must be physically articulated and moved until they separate from one another and/or visible joint surfaces. A similar ROM pattern is inferred for humeral pronation and supination. All final skeletonized ROMs were less than initial fully fleshed ROMs. These results are consistent with previously reported elbow joint ROM patterns from the extant phylogenetic bracket of dinosaurs. Thus, studies that avoid separation of complementary articular surfaces may be providing fossil shoulder joint ROMs that underestimate in vivo ROM in dinosaurs, as well as other fossil archosaurs.

  15. Full Range of Motion Induces Greater Muscle Damage Than Partial Range of Motion in Elbow Flexion Exercise With Free Weights.

    PubMed

    Baroni, Bruno M; Pompermayer, Marcelo G; Cini, Anelize; Peruzzolo, Amanda S; Radaelli, Régis; Brusco, Clarissa M; Pinto, Ronei S

    2017-08-01

    Baroni, BM, Pompermayer, MG, Cini, A, Peruzzolo, AS, Radaelli, R, Brusco, CM, and Pinto, RS. Full range of motion induces greater muscle damage than partial range of motion in elbow flexion exercise with free weights. J Strength Cond Res 31(8): 2223-2230, 2017-Load and range of motion (ROM) applied in resistance training (RT) affect the muscle damage magnitude and the recovery time-course. Because exercises performed with partial ROM allow a higher load compared with those with full ROM, this study investigated the acute effect of a traditional RT exercise using full ROM or partial ROM on muscle damage markers. Fourteen healthy men performed 4 sets of 10 concentric-eccentric repetitions of unilateral elbow flexion on the Scott bench. Arms were randomly assigned to partial-ROM (50-100°) and full-ROM (0-130°) conditions, and load was determined as 80% of 1 repetition maximum (1RM) in the full- and partial-ROM tests. Muscle damage markers were assessed preexercise, immediately, and 24, 48, and 72 hours after exercise. Primary outcomes were peak torque, muscle soreness during palpation and elbow extension, arm circumference, and joint ROM. The load lifted in the partial-ROM condition (1RM = 19.1 ± 3.0 kg) was 40 ± 18% higher compared with the full-ROM condition (1RM = 13.7 ± 2.2 kg). Seventy-two hours after exercise, the full-ROM condition led to significant higher soreness sensation during elbow extension (1.3-4.1 cm vs. 1.0-1.9 cm) and smaller ROM values (97.5-106.1° vs. 103.6-115.7°). Peak torque, soreness from palpation, and arm circumference were statistically similar between conditions, although mean values in all time points of these outcomes have suggested more expressive muscle damage for the full-ROM condition. In conclusion, elbow flexion exercise with full ROM seems to induce greater muscle damage than partial-ROM exercises, even though higher absolute load was achieved with partial ROM.

  16. Electrical Characteristics of WSi2 Nanocrystal Capacitors with Barrier-Engineered High-k Tunnel Layers

    NASA Astrophysics Data System (ADS)

    Lee, Hyo Jun; Lee, Dong Uk; Kim, Eun Kyu; You, Hee-Wook; Cho, Won-Ju

    2011-06-01

    Nanocrystal-floating gate capacitors with WSi2 nanocrystals and high-k tunnel layers were fabricated to improve the electrical properties such as retention, programming/erasing speed, and endurance. The WSi2 nanocrystals were distributed uniformly between the tunnel and control gate oxide layers. The electrical performance of the tunnel barrier with the SiO2/HfO2/Al2O3 (2/1/3 nm) (OHA) tunnel layer appeared to be better than that with the Al2O3/HfO2/Al2O3 (2/1/3 nm) (AHA) tunnel layer. When ΔVFB is about 1 V after applying voltage at ±8 V, the programming/erasing speeds of AHA and OHA tunnel layers are 300 ms and 500 µs, respectively. In particular, the device with WSi2 nanocrystals and the OHA tunnel barrier showed a large memory window of about 7.76 V when the voltage swept from 10 to -10 V, and it was maintained at about 2.77 V after 104 cycles.

  17. Experimental and theoretical studies of Sub-THz detection using strained-Si FETs

    NASA Astrophysics Data System (ADS)

    Delgado Notario, J. A.; Javadi, E.; Clericò, V.; Fobelets, K.; Otsuji, T.; Diez, E.; Velázquez-Pérez, J. E.; Meziani, Y. M.

    2017-10-01

    We report on experimental and theoretical studies of nanoscale gate-lengths strained Silicon MODFETs as room temperature non resonant detectors. Devices were excited at room temperature by an electronic source at 150 and 300 GHz to characterize their sub-THz response. The maximum of the photovoltaic response was obtained when the FET gate was biased at a value close to the threshold voltage. Simulations based on a bi-dimensional hydrodynamic model for the charge transport coupled to a Poisson equation solver were performed by using Synopsys TCAD. A charge boundary condition for the floating drain contact was implemented to obtain the photovoltaic response. Results from numerical simulations are in agreement with experimental ones. To understand the coupling between terahertz radiation and devices, the devices were rotated at different angles under excitation at both sub-terahertz frequencies and their response measured. Both NEP (Noise Equivalent Power) and Responsivity were calculated from measurements. To demonstrate their utility, devices were used as sensors in a terahertz imaging system for inspection of hidden objects at both frequencies.

  18. Environmental Effects on Data Retention in Flash Cells

    NASA Technical Reports Server (NTRS)

    Katz, Rich; Flowers, David; Bergevin, Keith

    2017-01-01

    Flash technology is being utilized in fuzed munition applications and, based on the development of digital logic devices in the commercial world, usage of flash technology will increase. Antifuse technology, prevalent in non-volatile field programmable gate arrays (FPGAs), will eventually be phased out as new devices have not been developed for approximately a decade. The reliance on flash technology presents a long-term reliability issue for both DoD and NASA safety- and mission-critical applications. A thorough understanding of the data retention failure modes and statistics associated with Flash data retention is of vital concern to the fuze safety community. A key retention parameter for a flash cell is the threshold voltage (VTH), which is an indirect indicator of the amount of charge stored on the cells floating gate. This paper will present the results of our on-going tests: long-term storage at 150 C for a small population of devices, neutron radiation exposure, electrostatic discharge (ESD) testing, and the trends of large populations (over 300 devices for each condition) exposed to three difference temperatures: 25 C, 125 C, and 150 C.

  19. CD-ROM in the High School Library [and] Some Guidelines for Purchasing a CD-ROM Workstation [and] ERIC for Librarians and Students Too [and] Online Serendipity.

    ERIC Educational Resources Information Center

    Kirsch, Robert A.; And Others

    1989-01-01

    The first article discusses CD-ROM pricing and provides a list of databases and magazines available on CD-ROM. The second provides guidelines for purchasing a CD-ROM workstation. The third describes the use of ERIC on CD-ROM as a research tool for high school students. The fourth describes the benefits of using online searching to teach research…

  20. CD-ROM Network Configurations: Good, Better, Best!

    ERIC Educational Resources Information Center

    McClanahan, Gloria

    1996-01-01

    Rates three methods of arranging CD-ROM school networks: (1) peer-to-peer; (2) daisy chain configurations; and (3) dedicated CD-ROM file server. Describes the following network components: the file server, network adapters and wiring, the CD-ROM file server, and CD-ROM drives. Discusses issues involved in assembling these components into a working…

  1. Reactive oxygen metabolites (ROMs) are associated with cardiovascular disease in chronic hemodialysis patients.

    PubMed

    Bossola, Maurizio; Vulpio, Carlo; Colacicco, Luigi; Scribano, Donata; Zuppi, Cecilia; Tazza, Luigi

    2012-02-11

    The aim of our study was to measure reactive oxygen metabolites (ROMs) in chronic hemodialysis (HD) patients and evaluate the possible association with cardiovascular disease (CVD) and mortality. We measured ROMs in 76 HD patients and correlated with CVD, cardiovascular (CV) events in the follow-up and all-cause and CVD-related mortality. The levels of ROMs presented a median value of 270 (238.2-303.2) CARR U (interquartile range). We created a ROC curve (ROMs levels vs. CVD) and we identified a cut-off point of 273 CARR U. Patients with ROMs levels ≥273 CARR U were significantly older, had higher C-reactive protein levels and lower creatinine concentrations. The prevalence of CVD was higher in patients with ROMs levels ≥273 (87.1%) than in those with ROMs levels <273 CARR U (17.7%; p<0.0001). ROMs levels were significantly higher in patients with CVD (317±63.8) than in those without (242.7±49.1; p<0.0001). At multiple regression analysis, age, creatinine and C-reactive protein were independent factors associated with ROMs. At multiple logistic regression analysis the association between ROMs and CVD was independent (OR: 1.02, 95% CI: 1.00-1.05; p=0.03). Twenty six patients developed cardiovascular (CV) events during the follow-up. Of these, seven were in the group with ROMs levels <273 CARR U and 19 in the group with ROMs levels ≥273 CARR U. The logistic regression analysis showed that both age (OR: 1.06, 95% CI: 1.01-1.12; p=0.013) and ROMs levels (OR: 1.10, 95% CI: 1.00-1.02; p=0.045) were independently associated with CV events in the follow-up. ROMs are independently associated with CVD and predict CV events in chronic HD patients.

  2. Novel organic semiconductors and a high capacitance gate dielectric for organic thin film transistors

    NASA Astrophysics Data System (ADS)

    Cai, Xiuyu

    2007-12-01

    Organic semiconductors are attracting more and more interest as a promising set of materials in the field of electronics research. This thesis focused on several new organic semiconductors and a novel high-kappa dielectric thin film (SrTiO3), which are two essential parts in Organic Thin Film Transistors (OTFTs). Structure and morphology of thin films of tricyanovinyl capped oligothiophenes were studied using atomic force microscopy and x-ray diffraction. Thin film transistors of one compound exhibited a reasonable electron mobility of 0.02 cm2/Vs. Temperature dependent measurements on the thin film transistor based on this compound revealed shallow trap states that were interpreted in terms of a multiple trap and release model. Moreover, inversion of the majority charge carrier type from electrons to holes was observed when the number of oligothiophene rings increased to six and ambipolar transport behavior was observed for tricyanovinyl sexithiophene. Another interesting organic semiconductor compound is the fluoalkylquarterthiophene, which showed ambipolar transport and large hysteresis in the transfer curve. Due to the bistable state at floating gate, the thin film transistor was exploited to study non-volatile floating gate memory effects. The temperature dependence of the retention time for this memory device revealed that the electron trapping was an activated process. Following the earlier work on hybrid acene-thiophene organic semiconductors, new compounds with similar structure were studied to reveal the mechanism of the air-stability exhibited by some compounds. They all formed highly crystalline thin films and showed reasonable device performances which are well correlated with the molecular structures, thin film microstructures, and solid state packing. The most air-stable compound had no observable degradation with exposure to air for 15 months. SrTiO3 was developed to be employed in OTFTs. Optimization of thin film growth was performed using reactive sputtering growth. Excellent SrTiO3 epitaixal thin film growth was revealed on conductive SrTiO 3:Nb substrates. A maximum charge carrier density of 1014 cm-2 was obtained based on pentacene and perylene diimide thin film transistors. Some new physical phenomena, such as step-like transfer characteristic curve and negative transconductance, were observed at such high field effect induced charge carrier density.

  3. 20-GFLOPS QR processor on a Xilinx Virtex-E FPGA

    NASA Astrophysics Data System (ADS)

    Walke, Richard L.; Smith, Robert W. M.; Lightbody, Gaye

    2000-11-01

    Adaptive beamforming can play an important role in sensor array systems in countering directional interference. In high-sample rate systems, such as radar and comms, the calculation of adaptive weights is a very computational task that requires highly parallel solutions. For systems where low power consumption and volume are important the only viable implementation is as an Application Specific Integrated Circuit (ASIC). However, the rapid advancement of Field Programmable Gate Array (FPGA) technology is enabling highly credible re-programmable solutions. In this paper we present the implementation of a scalable linear array processor for weight calculation using QR decomposition. We employ floating-point arithmetic with mantissa size optimized to the target application to minimize component size, and implement them as relationally placed macros (RPMs) on Xilinx Virtex FPGAs to achieve predictable dense layout and high-speed operation. We present results that show that 20GFLOPS of sustained computation on a single XCV3200E-8 Virtex-E FPGA is possible. We also describe the parameterized implementation of the floating-point operators and QR-processor, and the design methodology that enables us to rapidly generate complex FPGA implementations using the industry standard hardware description language VHDL.

  4. Coupling of protein localization and cell movements by a dynamically localized response regulator in Myxococcus xanthus

    PubMed Central

    Leonardy, Simone; Freymark, Gerald; Hebener, Sabrina; Ellehauge, Eva; Søgaard-Andersen, Lotte

    2007-01-01

    Myxococcus xanthus cells harbor two motility machineries, type IV pili (Tfp) and the A-engine. During reversals, the two machineries switch polarity synchronously. We present a mechanism that synchronizes this polarity switching. We identify the required for motility response regulator (RomR) as essential for A-motility. RomR localizes in a bipolar, asymmetric pattern with a large cluster at the lagging cell pole. The large RomR cluster relocates to the new lagging pole in parallel with cell reversals. Dynamic RomR localization is essential for cell reversals, suggesting that RomR relocalization induces the polarity switching of the A-engine. The analysis of RomR mutants shows that the output domain targets RomR to the poles and the receiver domain is essential for dynamic localization. The small GTPase MglA establishes correct RomR polarity, and the Frz two-component system regulates dynamic RomR localization. FrzS localizes with Tfp at the leading pole and relocates in an Frz-dependent manner to the opposite pole during reversals; FrzS and RomR localize and oscillate independently. The Frz system synchronizes these oscillations and thus the synchronous polarity switching of the motility machineries. PMID:17932488

  5. The clinical utility of cervical range of motion in diagnosis, prognosis, and evaluating the effects of manipulation: a systematic review.

    PubMed

    Snodgrass, Suzanne J; Cleland, Joshua A; Haskins, Robin; Rivett, Darren A

    2014-12-01

    Clinicians commonly assess cervical range of motion (ROM), but it has rarely been critically evaluated for its ability to contribute to patient diagnosis or prognosis, or whether it is affected by mobilisation/manipulation. This review summarises the methods used to measure cervical ROM in research involving patients with cervical spine disorders, reviews the evidence for using cervical ROM in patient diagnosis, prognosis, and evaluation of the effects of mobilisation/manipulation on cervical ROM. A systematic search of MEDLINE, EMBASE, CINAHL, AMED and ICL databases was conducted, addressing one of four constructs related to cervical ROM: measurement, diagnosis, prognosis, and the effects of mobilisation/manipulation on cervical ROM. Two independent raters appraised methodological quality using the QUADAS-2 tool for diagnostic studies, the QUIPS tool for prognostic studies and the PEDro scale for interventional studies. Heterogeneity of studies prevented meta-analysis. Thirty-six studies met the criteria and findings showed there is limited evidence for the diagnostic value of cervical ROM in cervicogenic headache, cervical radiculopathy and cervical spine injury. There is conflicting evidence for the prognostic value of cervical ROM, though restricted ROM appears associated with negative outcomes while greater ROM is associated with positive outcomes. There is conflicting evidence as to whether cervical ROM increases or decreases following mobilisation/manipulation. Cervical ROM has value as one component of assessment, but clinicians should be cautious about making clinical judgments primarily on the basis of cervical ROM. This collaboration was supported by an internal grant from the Faculty of Health, The University of Newcastle. Copyright © 2014 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  6. Comparison of shoulder internal rotation passive range of motion in various positions in nonathletic persons and the establishment of normative values for the sidelying position.

    PubMed

    Cieminski, Cort J; Kelly, Shannon M; Nawrocki, Tatia J; Indrelie, Alisse J; Klaers, Hugo; Stelzmiller, Michael R

    2016-09-01

    Loss of shoulder internal rotation (IR) range of motion (ROM) is prevalent in overhead athletes, but it can also be seen in nonathletic persons. A paucity of normative data exists, however, for shoulder IR ROM in positions other than supine, especially in nonathletic persons. The aim of this study was to determine shoulder IR ROM differences between the sidelying, semi-sidelying, and supine positions as well as to establish initial normative values for IR ROM for the sidelying and semi-sidelying positions in nonathletic persons. IR ROM was measured on 204 nonathletic persons using the sidelying, semi-sidelying, and supine positions. Mean values of IR ROM for each position were calculated. Differences in IR ROM across the 3 positions and side-to-side differences were examined, including the influence of sex and age on IR ROM. Intra-rater and inter-rater reliability for the sidelying position was excellent. The sidelying position had significantly less IR ROM compared with the other positions, and there was a significant side-to-side IR ROM difference, greatest for the sidelying position (6.8°). Women had significantly more IR ROM than men did, with sidelying normative values of 49° and 55° for female dominant and nondominant shoulders, respectively, and 42° and 51° for male dominant and nondominant shoulders, respectively. This investigation establishes initial normative IR ROM values for the sidelying position for both shoulders and sexes. Health care providers can begin to examine IR ROM deficits using these normative values for the sidelying position. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  7. Retention of data in heat-damaged SIM cards and potential recovery methods.

    PubMed

    Jones, B J; Kenyon, A J

    2008-05-02

    Examination of various SIM cards and smart card devices indicates that data may be retained in SIM card memory structures even after heating to temperatures up to 450 degrees C, which the National Institute of Standards and Technology (NIST) has determined to be approximately the maximum average sustained temperature at desk height in a house fire. However, in many cases, and certainly for temperatures greater than 450 degrees C, the SIM card chip has suffered structural or mechanical damage that renders simple probing or rewiring ineffective. Nevertheless, this has not necessarily affected the data, which is stored as charge in floating gates, and alternative methods for directly accessing the stored charge may be applicable.

  8. Distribution of Databases on CD-Rom

    DTIC Science & Technology

    1990-09-01

    capabilities, advantages and disadvantages of CD-ROM technology lo determine whelher its use would be a preferred strategy for fulfilling information...capabilities, advantages and disadvantages of CD-ROM technology to determine whether its use would be a preferred strategy for fulfilling information...A. GENERAL 1 B. OBJECTIVE 1 C. RESEARCH METHODOLOGY 2 II. WHAT IS CD-ROM? 3 A. BACKGROUND 3 III. ADVANTAGES AND DISADVANTAGES OF CD-ROM

  9. Knee arthritis pain is reduced and range of motion is increased following moderate pressure massage therapy.

    PubMed

    Field, Tiffany; Diego, Miguel; Gonzalez, Gladys; Funk, C G

    2015-11-01

    The literature on massage therapy effects on knee pain suggests that pain was reduced based on self-report, but little is known about range of motion (ROM) effects. Medical School staff and faculty who had knee arthritis pain were randomly assigned to a moderate pressure massage therapy or a waitlist control group (24 per group). Self-reports included the WOMAC (pain, stiffness and function) and the Pittsburgh Sleep Quality Index. ROM and ROM-related pain were assessed before and after the last sessions. The massage group showed an immediate post-massage increase in ROM and a decrease in ROM-associated pain. On the last versus the first day of the study, the massage group showed greater increases in ROM and decreases in ROM-related pain as well as less self-reported pain and sleep disturbances than the waitlist control group. These data highlight the effectiveness of moderate pressure massage therapy for increasing ROM and lessening ROM-related pain and long-term pain and sleep disturbances. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Impact of Preferred Eddy Tracks on Transport and Mixing in the Eastern South Pacific

    NASA Astrophysics Data System (ADS)

    Belmadani, A.; Donoso, D.; Auger, P. A.; Chaigneau, A.

    2017-12-01

    Mesoscale eddies, which play a fundamental role in the transport of mass, heat, nutrients, and biota across the oceans, have been suggested to propagate preferently along specific tracks. These preferred pathways, also called eddy trains, are near-zonal due to westward drift of individual vortices, and tend to be polarized (ie alternatively dominated by anticyclonic/cyclonic eddies), coinciding with the recently discovered latent striations (quasi-zonal mesoscale jet-like features). While significant effort has been made to understand the dynamics of striations and their interplay with mesoscale eddies, the impact of repeated eddy tracks on physical (temperature, salinity), biogeochemical (oxygen, carbon, nutrients) and other tracers (e.g. chlorophyll, marine debris) has received little attention. Here we report on the results of numerical modeling experiments that simulate the impact of preferred eddy tracks on the transport and mixing of water particles in the Eastern South Pacific off Chile. A 30-year interannual simulation of the oceanic circulation in this region has been performed over 1984-2013 with the ROMS (Regional Oceanic Modeling System) at an eddy-resolving resolution (10 km). Objective tracking of mesoscale coherent vortices is obtained using automated methods, allowing to compute the contribution of eddies to the ocean circulation. Preferred eddy tracks are further isolated from the more random eddies, by comparing the distances between individual tracks and the striated pattern in long-term mean eddy polarity with a least-squares approach. The remaining non-eddying flow may also be decomposed into time-mean and anomalous circulation, and/or small- and large-scale circulation. Neutrally-buoyant Lagrangian floats are then released uniformly into the various flow components as well as the total flow, and tracked forward in time with the ARIANE software. The dispersion patterns of water particles are used to estimate the respective contributions of organized and random eddies, mean flow, large-scale perturbations etc. to mixing properties and transport pathways. Float release into the full flow inside selected vortices is also used to document the impact of eddy trains on the transformation of water masses inferred from changes in temperature/salinity along float trajectories.

  11. Effect of partitioning the nonfiber carbohydrate fraction and neutral detergent fiber method on digestibility of carbohydrates by dairy cows.

    PubMed

    Tebbe, A W; Faulkner, M J; Weiss, W P

    2017-08-01

    Many nutrition models rely on summative equations to estimate feed and diet energy concentrations. These models partition feed into nutrient fractions and multiply the fractions by their estimated true digestibility, and the digestible mass provided by each fraction is then summed and converted to an energy value. Nonfiber carbohydrate (NFC) is used in many models. Although it behaves as a nutritionally uniform fraction, it is a heterogeneous mixture of components. To reduce the heterogeneity, we partitioned NFC into starch and residual organic matter (ROM), which is calculated as 100 - CP - LCFA - ash - starch - NDF, where crude protein (CP), long-chain fatty acids (LCFA), ash, starch, and neutral detergent fiber (NDF) are a percentage of DM. However, the true digestibility of ROM is unknown, and because NDF is contaminated with both ash and CP, those components are subtracted twice. The effect of ash and CP contamination of NDF on in vivo digestibility of NDF and ROM was evaluated using data from 2 total-collection digestibility experiments using lactating dairy cows. Digestibility of NDF was greater when it was corrected for ash and CP than without correction. Conversely, ROM apparent digestibility decreased when NDF was corrected for contamination. Although correcting for contamination statistically increased NDF digestibility, the effect was small; the average increase was 3.4%. The decrease in ROM digestibility was 7.4%. True digestibility of ROM is needed to incorporate ROM into summative equations. Data from multiple digestibility experiments (38 diets) using dairy cows were collated, and ROM concentrations were regressed on concentration of digestible ROM (ROM was calculated without adjusting for ash and CP contamination). The estimated true digestibility coefficient of ROM was 0.96 (SE = 0.021), and metabolic fecal ROM was 3.43 g/100 g of dry matter intake (SE = 0.30). Using a smaller data set (7 diets), estimated true digestibility of ROM when calculated using NDF corrected for ash and CP contamination was 0.87 (SE = 0.025), and metabolic fecal ROM was 3.76 g/100 g (SE = 0.60). Regardless of NDF method, ROM exhibited nutritional uniformity. The ROM fraction also had lower errors associated with the estimated true digestibility and its metabolic fecal fraction than did NFC. Therefore, ROM may result in more accurate estimates of available energy if integrated into models. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  12. CD-ROM Hardware Configurations: Selection and Design.

    ERIC Educational Resources Information Center

    Jaffe, Lee David; Watkins, Steven G.

    1992-01-01

    Presents selection and design considerations to help libraries make informed decisions about hardware configurations of CD-ROM systems. Highlights include CD-ROM configurations, including single drive workstations, daisychains, and jukeboxes; network configurations, including remote access; microcomputer features; CD-ROM drive selection; and…

  13. Associations of passive muscle stiffness, muscle stretch tolerance, and muscle slack angle with range of motion: individual and sex differences.

    PubMed

    Miyamoto, Naokazu; Hirata, Kosuke; Miyamoto-Mikami, Eri; Yasuda, Osamu; Kanehisa, Hiroaki

    2018-05-29

    Joint range of motion (ROM) is an important parameter for athletic performance and muscular injury risk. Nonetheless, a complete description of muscular factors influencing ROM among individuals and between men and women is lacking. We examined whether passive muscle stiffness (evaluated by angle-specific muscle shear modulus), tolerance to muscle stretch (evaluated by muscle shear modulus at end-ROM), and muscle slack angle of the triceps surae are associated with the individual variability and sex difference in dorsiflexion ROM, using ultrasound shear wave elastography. For men, ROM was negatively correlated to passive muscle stiffness of the medial and lateral gastrocnemius in a tensioned state and positively to tolerance to muscle stretch in the medial gastrocnemius. For women, ROM was only positively correlated to tolerance to muscle stretch in all muscles but not correlated to passive muscle stiffness. Muscle slack angle was not correlated to ROM in men and women. Significant sex differences were observed only for dorsiflexion ROM and passive muscle stiffness in a tensioned state. These findings suggest that muscular factors associated with ROM are different between men and women. Furthermore, the sex difference in dorsiflexion ROM might be attributed partly to that in passive muscle stiffness of plantar flexors.

  14. Range of Motion of the Ankle According to Pushing Force, Gender and Knee Position.

    PubMed

    Cho, Kang Hee; Jeon, Yumi; Lee, Hyunkeun

    2016-04-01

    To investigate the difference of range of motion (ROM) of ankle according to pushing force, gender and knee position. One hundred and twenty-eight healthy adults (55 men, 73 women) between the ages of 20 and 51, were included in the study. One examiner measured the passive range of motion (PROM) of ankle by Dualer IQ Inclinometers and Commander Muscle Testing. ROM of ankle dorsiflexion (DF) and plantarflexion (PF) according to change of pushing force and knee position were measured at prone position. There was significant correlation between ROM and pushing force, the more pushing force leads the more ROM at ankle DF and ankle PF. Knee flexion of 90° position showed low PF angle and high ankle DF angle, as compared to the at neutral position of knee joint. ROM of ankle DF for female was greater than for male, with no significant difference. ROM of ankle PF for female was greater than male regardless of the pushing force. To our knowledge, this is the first study to assess the relationship between pushing force and ROM of ankle joint. There was significant correlation between ROM of ankle and pushing force. ROM of ankle PF for female estimated greater than male regardless of the pushing force and the number of measurement. The ROM of the ankle is measured differently according to the knee joint position. Pushing force, gender and knee joint position are required to be considered when measuring the ROM of ankle joint.

  15. Determination of vertebral range of motion using inertial measurement units in 27 Franches-Montagnes stallions and comparison between conditions and with a mixed population.

    PubMed

    Heim, C; Pfau, T; Gerber, V; Schweizer, C; Doherr, M; Schüpbach-Regula, G; Witte, S

    2016-07-01

    The diagnosis of equine back disorders is challenging. Objectively determining movement of the vertebral column may therefore be of value in a clinical setting. To establish whether surface-mounted inertial measurement units (IMUs) can be used to establish normal values for range of motion (ROM) of the vertebral column in a uniform population of horses trotting under different conditions. Vertebral ROM was established in Franches-Montagnes stallions and a general population of horses and the variability in measurements compared between the two groups. Repeatability and the influence of specific exercise condition (on ROM) were assessed. Finally, attempts were made to explain the findings of the study through the evaluation of factors that might influence ROM. Dorsoventral (DV) and mediolateral (ML) vertebral ROM was measured at a trot under different exercise conditions in 27 Franches-Montagnes stallions and six general population horses using IMUs distributed over the vertebral column. Variability in the ROM measurements was significantly higher for general population horses than for Franches-Montagnes stallions (both DV and ML ROM). Repeatability was strong to very strong for DV measurements and moderate for ML measurements. Trotting under saddle significantly reduced the ROM, with sitting trot resulting in a significantly lower ROM than rising trot. Age is unlikely to explain the low variability in vertebral ROM recorded in the Franches-Montagnes horses, while this may be associated with conformational factors. It was possible to establish a normal vertebral ROM for a group of Franches-Montagnes stallions. While within-breed variation was low in this population, further studies are necessary to determine variation in vertebral ROM for other breeds and to assess their utility for diagnosis of equine back disorders. © 2015 EVJ Ltd.

  16. Is there a role for rifampicin, ofloxacin and minocycline (ROM) therapy in the treatment of leprosy? Systematic review and meta-analysis.

    PubMed

    Setia, Maninder S; Shinde, Santosh S; Jerajani, Hemangi R; Boivin, Jean-François

    2011-12-01

    A combination of rifampicin, ofloxacin and minocycline (ROM) is one of the newer recommendations for treatment of leprosy. We performed a systematic review and a meta-analysis of studies that had evaluated the efficacy of ROM therapy in treatment of paucibacillary and multibacillary leprosy patients. Studies were identified by searching the PubMed, Embase, LILACS and Cochrane databases. Data were abstracted from all relevant studies, and fixed effects models were used to calculate the summary estimate of effect in paucibacillary and multibacillary leprosy patients. Six studies comparing ROM therapy to multidrug therapy and eight studies that evaluated the effect of ROM therapy alone (no comparison group) were included in the review and meta-analysis. The combined estimate for single dose ROM vs. multidrug therapy in paucibacillary leprosy patients suggested that ROM was less effective than multidrug therapy in these patients [relative risk: 0.91, 95% confidence intervals (CI): 0.86-0.97]. However, the combined estimate for multiple doses of ROM vs. multidrug therapy in multibacillary leprosy patients suggested that ROM was as effective as multidrug therapy in reducing bacillary indices in these patients (proportion change: -4%, 95% CI -31% to 23%). No major side effects were reported in either the ROM or the multidrug treatment groups. Single-dose ROM therapy was less effective than multidrug therapy in paucibacillary patients. However, there are insufficient data to come to a valid conclusion on the efficacy of multidose ROM therapy in multibacillary leprosy, and additional studies with ROM therapy in multibacillary leprosy are needed. Furthermore, multiple doses may be considered as another alternative even for paucibacillary patients, and randomised controlled trials of this therapy may be useful to understand its contribution in the treatment and control of leprosy. © 2011 Blackwell Publishing Ltd.

  17. Measurement of Shoulder Range of Motion in Patients with Adhesive Capsulitis Using a Kinect

    PubMed Central

    Chung, Sun Gun; Kim, Hee Chan; Kwak, Youngbin; Park, Hee-won; Kim, Keewon

    2015-01-01

    Range of motion (ROM) measurements are essential for the evaluation for and diagnosis of adhesive capsulitis of the shoulder (AC). However, taking these measurements using a goniometer is inconvenient and sometimes unreliable. The Kinect (Microsoft, Seattle, WA, USA) is gaining attention as a new motion detecting device that is nonintrusive and easy to implement. This study aimed to apply Kinect to measure shoulder ROM in AC; we evaluated its validity by calculating the agreement of the measurements obtained using Kinect with those obtained using goniometer and assessed its utility for the diagnosis of AC. Both shoulders of 15 healthy volunteers and affected shoulders of 12 patients with AC were included in the study. The passive and active ROM of each were measured with a goniometer for flexion, abduction, and external rotation. Their active shoulder motions for each direction were again captured using Kinect and the ROM values were calculated. The agreement between the two measurements was tested with the intraclass correlation coefficient (ICC). Diagnostic performance using the Kinect ROM was evaluated with Cohen’s kappa value. The cutoff values of the limited ROM were determined in the following ways: the same as passive ROM values, reflecting the mean difference, and based on receiver operating characteristic curves. The ICC for flexion/abduction/external rotation between goniometric passive ROM and the Kinect ROM were 0.906/0.942/0.911, while those between active ROMs and the Kinect ROMs were 0.864/0.932/0.925. Cohen’s kappa values were 0.88, 0.88, and 1.0 with the cutoff values in the order above. Measurements of the shoulder ROM using Kinect show excellent agreement with those taken using a goniometer. These results indicate that the Kinect can be used to measure shoulder ROM and to diagnose AC as an alternative to goniometer. PMID:26107943

  18. Radio-controlled boat for measuring water velocities and bathymetry

    NASA Astrophysics Data System (ADS)

    Vidmar, Andrej; Bezak, Nejc; Sečnik, Matej

    2016-04-01

    Radio-controlled boat named "Hi3" was designed and developed in order to facilitate water velocity and bathymetry measurements. The boat is equipped with the SonTek RiverSurveyor M9 instrument that is designed for measuring open channel hydraulics (discharge and bathymetry). Usually channel cross sections measurements are performed either from a bridge or from a vessel. However, these approaches have some limitations such as performing bathymetry measurements close to the hydropower plant turbine or downstream from a hydropower plant gate where bathymetry changes are often the most extreme. Therefore, the radio-controlled boat was designed, built and tested in order overcome these limitations. The boat is made from a surf board and two additional small balance support floats. Additional floats are used to improve stability in fast flowing and turbulent parts of rivers. The boat is powered by two electric motors, steering is achieved with changing the power applied to left and right motor. Furthermore, remotely controlled boat "Hi3" can be powered in two ways, either by a gasoline electric generator or by lithium batteries. Lithium batteries are lighter, quieter, but they operation time is shorter compared to an electrical generator. With the radio-controlled boat "Hi3" we can perform measurements in potentially dangerous areas such as under the lock gates at hydroelectric power plant or near the turbine outflow. Until today, the boat "Hi3" has driven more than 200 km in lakes and rivers, performing various water speed and bathymetry measurements. Moreover, in future development the boat "Hi3" will be upgraded in order to be able to perform measurements automatically. The future plans are to develop and implement the autopilot. With this approach the user will define the route that has to be driven by the boat and the boat will drive the pre-defined route automatically. This will be possible because of the very accurate differential GPS from the Sontek RiverSurveyor M9 instrument.

  19. Stabilization Approaches for Linear and Nonlinear Reduced Order Models

    NASA Astrophysics Data System (ADS)

    Rezaian, Elnaz; Wei, Mingjun

    2017-11-01

    It has been a major concern to establish reduced order models (ROMs) as reliable representatives of the dynamics inherent in high fidelity simulations, while fast computation is achieved. In practice it comes to stability and accuracy of ROMs. Given the inviscid nature of Euler equations it becomes more challenging to achieve stability, especially where moving discontinuities exist. Originally unstable linear and nonlinear ROMs are stabilized here by two approaches. First, a hybrid method is developed by integrating two different stabilization algorithms. At the same time, symmetry inner product is introduced in the generation of ROMs for its known robust behavior for compressible flows. Results have shown a notable improvement in computational efficiency and robustness compared to similar approaches. Second, a new stabilization algorithm is developed specifically for nonlinear ROMs. This method adopts Particle Swarm Optimization to enforce a bounded ROM response for minimum discrepancy between the high fidelity simulation and the ROM outputs. Promising results are obtained in its application on the nonlinear ROM of an inviscid fluid flow with discontinuities. Supported by ARL.

  20. Evaluation of reactive oxygen metabolites in patients with non-small cell lung cancer after chemotherapy.

    PubMed

    Wakabayashi, Toru; Kawashima, Tatsuo; Matsuzawa, Yasuo

    2014-01-01

    The aim of this study was to evaluate the level of reactive oxygen metabolites (ROMs) after chemotherapy in patients with non-small cell lung cancer (NSCLC) and its association with response to treatment. Fifty-eight untreated NSCLC patients and twenty-three healthy subjects were selected for the study. Patients received two courses of platinum-based chemotherapy and were evaluated for oxidative stress and treatment response. As a marker of reactive oxygen species, ROMs levels were measured using the d-ROMs test. ROMs level (mean ± standard deviation) before chemotherapy in NSCLC patients (416 ± 135 U.CARR) was significantly elevated (p = 0.016) compared to normal healthy subjects (320 ± 59 U.CARR). Patients who responded to chemotherapy showed significantly decreased (p = 0.014) ROMs levels after chemotherapy, whereas patients who had stable disease or progressive disease showed no change in ROMs level (p = 0.387). NSCLC patients had significantly elevated ROMs levels before chemotherapy compared with normal healthy subjects. Chemotherapy may suppress ROMs production in responders but not in non-responders. ROMs level may be a predictor of clinical outcome in patients receiving chemotherapy for NSCLC.

  1. CD-ROM Growth: Unleashing the Potential.

    ERIC Educational Resources Information Center

    Nelson, Nancy Melin

    1991-01-01

    Discusses the use of CD-ROMs in library processing and public services units. Topics discussed include local area networks, workstations, network security, search software, disk operating systems (DOS), computer viruses, CD-ROM selection and acquisition, licensing, and standards. A sidebar lists current CD-ROM products appropriate for reference…

  2. CD-ROM preparation: An overview and guide

    NASA Technical Reports Server (NTRS)

    Daniel, Ralph E.; Jeschke, Mark W.; Schroer, James A.

    1995-01-01

    A primer on the options and procedures involved in producing CD-ROM products in a small to medium sized business operation is presented in language that persons with a minimal technical background can easily understand. The capabilities, limitations, and standards of CD-ROM technology are surveyed. Emphasis is placed on CD-ROM production, especially upon design, data conversion to an electronic medium, data file preparation, the use of vendors, and the steps for in-house production of CD-ROM products.

  3. Preparation of rotigotine-loaded microspheres and their combination use with L-DOPA to modify dyskinesias in 6-OHDA-lesioned rats.

    PubMed

    Wang, Aiping; Wang, Lexi; Sun, Kaoxiang; Liu, Wanhui; Sha, Chunjie; Li, Youxin

    2012-09-01

    To prepare rotigotine loaded microspheres (RoMS) to achieve continuous dopaminergic stimulation (CDS) for the treatment of Parkinson's disease (PD) and investigate both the therapeutic benefit and inducibility of AIMs of administration of RoMS combination with L-DOPA in 6-OHDA-leisioned rats. Rotigotine was encapsulated into poly(lactic-co-glycolic acid) (PLGA) microspheres by an oil-in-water emulsion solvent evaporation technique. In vitro characteristics and in vivo pharmacokinetics of RoMS either in rat blood or brain (by microdialysis) were investigated. Contraversive rotations and AIMs were observed to investigate the therapeutic benefit and the propensity to induce dyskinesia of RoMS or RoMS combination with L-DOPA in 6-OHDA-lesioned rats. RoMS displayed continuous-release characteristics of rotigotine in animals and exhibited a steady efficacy lasted for 2 weeks in 6-OHDA-lesioned rats. No significant difference of the therapeutic benefit between the treatment of RoMS and pulsatile L-DOPA combination and mono L-DOPA was found. While the dyskinesia was significantly decreased with the treatment of RoMS and pulsatile L-DOPA combination compared to mono L-DOPA. RoMS could supply an alternative of CDS for the treatment of PD and the study indicates a potential advantage of RoMS for the treatment of mild and advanced PD patient in combination with L-DOPA.

  4. Programmable ion-sensitive transistor interfaces. II. Biomolecular sensing and manipulation.

    PubMed

    Jayant, Krishna; Auluck, Kshitij; Funke, Mary; Anwar, Sharlin; Phelps, Joshua B; Gordon, Philip H; Rajwade, Shantanu R; Kan, Edwin C

    2013-07-01

    The chemoreceptive neuron metal-oxide-semiconductor transistor described in the preceding paper is further used to monitor the adsorption and interaction of DNA molecules and subsequently manipulate the adsorbed biomolecules with injected static charge. Adsorption of DNA molecules onto poly-L-lysine-coated sensing gates (SGs) modulates the floating gate (FG) potential ψ(O), which is reflected as a threshold voltage shift measured from the control gate (CG) V(th_CG). The asymmetric capacitive coupling between the CG and SG to the FG results in V(th_CG) amplification. The electric field in the SG oxide E(SG_ox) is fundamentally different when we drive the current readout with V(CG) and V(ref) (i.e., the potential applied to the CG and reference electrode, respectively). The V(CG)-driven readout induces a larger E(SG_ox), leading to a larger V(th_CG) shift when DNA is present. Simulation studies indicate that the counterion screening within the DNA membrane is responsible for this effect. The DNA manipulation mechanism is enabled by tunneling electrons (program) or holes (erase) onto FGs to produce repulsive or attractive forces. Programming leads to repulsion and eventual desorption of DNA, while erasing reestablishes adsorption. We further show that injected holes or electrons prior to DNA addition either aids or disrupts the immobilization process, which can be used for addressable sensor interfaces. To further substantiate DNA manipulation, we used impedance spectroscopy with a split ac-dc technique to reveal the net interface impedance before and after charge injection.

  5. Range of Motion of the Ankle According to Pushing Force, Gender and Knee Position

    PubMed Central

    Cho, Kang Hee; Lee, Hyunkeun

    2016-01-01

    Objective To investigate the difference of range of motion (ROM) of ankle according to pushing force, gender and knee position. Methods One hundred and twenty-eight healthy adults (55 men, 73 women) between the ages of 20 and 51, were included in the study. One examiner measured the passive range of motion (PROM) of ankle by Dualer IQ Inclinometers and Commander Muscle Testing. ROM of ankle dorsiflexion (DF) and plantarflexion (PF) according to change of pushing force and knee position were measured at prone position. Results There was significant correlation between ROM and pushing force, the more pushing force leads the more ROM at ankle DF and ankle PF. Knee flexion of 90° position showed low PF angle and high ankle DF angle, as compared to the at neutral position of knee joint. ROM of ankle DF for female was greater than for male, with no significant difference. ROM of ankle PF for female was greater than male regardless of the pushing force. Conclusion To our knowledge, this is the first study to assess the relationship between pushing force and ROM of ankle joint. There was significant correlation between ROM of ankle and pushing force. ROM of ankle PF for female estimated greater than male regardless of the pushing force and the number of measurement. The ROM of the ankle is measured differently according to the knee joint position. Pushing force, gender and knee joint position are required to be considered when measuring the ROM of ankle joint. PMID:27152277

  6. When the Chips Are Down.

    ERIC Educational Resources Information Center

    Ashton, Ray

    1995-01-01

    Strips away advertising hyperbole to explain multimedia CD-ROM technology and its place in today's classrooms. Only the newest computers are adequate for multimedia CD-ROM; only 10% of all computers in schools have CD-ROM drives attached. CD-ROM drives' performance varies, installation hassles abound, and the "edutainment" market directs…

  7. Questions to Answer before You Branch out on a CD-ROM Network.

    ERIC Educational Resources Information Center

    Simpson, Carol Mann

    1992-01-01

    Examines issues that librarians must address when purchasing databases on CD-ROM for networking. Highlights include network licenses; costs; restrictions on network rights; ownership of CD-ROMs; hardware requirements; fees for upgrading software; CD-ROM servers; pricing options; training materials; and disk drives. (LRW)

  8. Networking the Light Fantastic--CD-ROMs on LANs.

    ERIC Educational Resources Information Center

    Kittle, Paul W.

    1992-01-01

    Describes the development of a local area network (LAN) at Loma Linda University that allows remote access for both IBM and Macintosh microcomputers to CD-ROMs. Topics discussed include types of networks; fiber optic technology; networking CD-ROM drives; remote access; modems; CD-ROM databases; memory management; interface software; and future…

  9. A heterozygous putative null mutation in ROM1 without a mutation in peripherin/RDS in a family with retinitis pigmentosa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sakuma, Hitoshi; Inana, G.; Murakami, Akira

    1995-05-20

    ROM1 is a 351-amino-acid, 37-kDa outer segment membrane protein of rod photoreceptors. ROM1 is related to peripherin/RDS, another outer segment membrane protein found in both rods and cones. The precise function of ROM1 or peripherin/RDS is not known, but they have been suggested to play important roles in the function and/or structure of the rod photoreceptor outer segment disks. A recent report implicated ROM1 in disease by suggesting that RP can be caused by a heterozygous null mutation in ROM1 but only in combination with another heterozygous mutation in peripherin/RDS. Screening of the ROM1 gene using polymerase chain reaction amplification,more » denaturing gradient gel electrophoresis, and direct DNA sequencing identified the same heterozygous putative null mutation in a family with RP.« less

  10. Publication of science data on CD-ROM: A guide and example

    NASA Technical Reports Server (NTRS)

    Angelici, Gary; Skiles, J. W.

    1993-01-01

    CD-ROM (Compact Disk-Read Only Memory) is becoming the standard media not only in audio recording, but also in the publication of data and information accessible on many computer platforms. Little has been written about the complicated process involved in creating easy-to-use, high quality, and useful CD-ROM's containing scientific data. This document is a manual designed to aid those who are responsible for the publication of scientific data on CD-ROM. All aspects and steps of the procedure are covered, from feasibility assessment through disk design, data preparation, disc mastering, and CD-ROM distribution. General advice and actual examples are based on lessons learned from the publication of scientific data for an interdisciplinary field experiment. Appendices include actual files from a CD-ROM, a purchase request for CD-ROM mastering services, and the disk art for the first disk published for the project.

  11. Recent Enhancements to the Development of CFD-Based Aeroelastic Reduced-Order Models

    NASA Technical Reports Server (NTRS)

    Silva, Walter A.

    2007-01-01

    Recent enhancements to the development of CFD-based unsteady aerodynamic and aeroelastic reduced-order models (ROMs) are presented. These enhancements include the simultaneous application of structural modes as CFD input, static aeroelastic analysis using a ROM, and matched-point solutions using a ROM. The simultaneous application of structural modes as CFD input enables the computation of the unsteady aerodynamic state-space matrices with a single CFD execution, independent of the number of structural modes. The responses obtained from a simultaneous excitation of the CFD-based unsteady aerodynamic system are processed using system identification techniques in order to generate an unsteady aerodynamic state-space ROM. Once the unsteady aerodynamic state-space ROM is generated, a method for computing the static aeroelastic response using this unsteady aerodynamic ROM and a state-space model of the structure, is presented. Finally, a method is presented that enables the computation of matchedpoint solutions using a single ROM that is applicable over a range of dynamic pressures and velocities for a given Mach number. These enhancements represent a significant advancement of unsteady aerodynamic and aeroelastic ROM technology.

  12. Maternal and neonatal evaluation of derivated reactive oxygen metabolites (d-ROMs) and biological antioxidant potential in the horse.

    PubMed

    Sgorbini, M; Bonelli, F; Marmorini, P; Biagi, G; Corazza, M; Pasquini, A

    2015-01-01

    The aim of the present work was to evaluate derivated reactive oxygen metabolites (d-ROMs) and biological antioxidant potential (BAP) in mares and foals to study perinatal oxidative status. A total of 60 animals were included in the present study. Maternal and foal venous blood samples were collected immediately after delivery along with a sample drawn from one of the umbilical arteries, and plasma samples were evaluated for lactatemia, d-ROMs, and BAP. The t test for unpaired data was applied between mares versus umbilical artery blood versus foals, both for d-ROMs and BAP. The Pearson test with two-tailed P value and a confidence interval of 95% was performed between d-ROMs and BAP and between d-ROMs and lactatemia, both for mares and foals. Finally, the t test for unpaired data was performed between fillies and colts. The t test showed differences between mares versus their own foals versus umbilical artery blood but not foals versus. umbilical artery blood, both for d-ROMs and BAP. A positive correlation was found both in mares and foals between BAP and d-ROMs and in mares between lactatemia and d-ROM. No differences in gender were found in BAP concentration. Our data are in line to previous studies performed in women and cattle.

  13. Evaluation of reactive oxygen metabolites in patients with non-small cell lung cancer after chemotherapy

    PubMed Central

    2014-01-01

    Background The aim of this study was to evaluate the level of reactive oxygen metabolites (ROMs) after chemotherapy in patients with non-small cell lung cancer (NSCLC) and its association with response to treatment. Methods Fifty-eight untreated NSCLC patients and twenty-three healthy subjects were selected for the study. Patients received two courses of platinum-based chemotherapy and were evaluated for oxidative stress and treatment response. As a marker of reactive oxygen species, ROMs levels were measured using the d-ROMs test. Results ROMs level (mean ± standard deviation) before chemotherapy in NSCLC patients (416 ± 135 U.CARR) was significantly elevated (p = 0.016) compared to normal healthy subjects (320 ± 59 U.CARR). Patients who responded to chemotherapy showed significantly decreased (p = 0.014) ROMs levels after chemotherapy, whereas patients who had stable disease or progressive disease showed no change in ROMs level (p = 0.387). Conclusions NSCLC patients had significantly elevated ROMs levels before chemotherapy compared with normal healthy subjects. Chemotherapy may suppress ROMs production in responders but not in non-responders. ROMs level may be a predictor of clinical outcome in patients receiving chemotherapy for NSCLC. PMID:25180083

  14. Variability of Tropical Cyclone Heat Potential and Barrier layers in the South Indian Ocean

    NASA Astrophysics Data System (ADS)

    Mawren, D.; Reason, C. J. C.

    2016-02-01

    This study investigates the influence of Tropical Cyclone Heat Potential (TCHP) as well as salinity stratification during the passage of intense tropical cyclones. Using in-situ observations, reanalysis data and ocean model simulations, this study indicates that TC intensification is affected by high TCHP values and deep barrier layers. TCHP computed from 1/5° resolution regional ocean model (ROMS) agrees well with that derived from Argo float data and SODA which extends over a longer period (1950-2010). Time series of TCHP in the South Indian Ocean shows strongest interannual variability during 1997-1998, 2003, 2007 and is relatively highly correlated at 1 month lag with ENSO (r = 0.67, significant at 95 %). The interannual variability of barrier layer thickness (BLT) was analyzed over the Seychelles-Chagos thermocline ridge (SCTR) and high-amplitude fluctuations in BLT appear to overlay with large positive TCHP values. Analysis also shows that both BLT and TCHP are modulated by the westward propagating Rossby waves. A case study of Category 5 Tropical cyclone BANSI that developed over and east of Madagascar during 11-18 Jan 2015 is presented.

  15. Significance of measuring oxidative stress in lifestyle-related diseases from the viewpoint of correlation between d-ROMs and BAP in Japanese subjects.

    PubMed

    Fukui, Toshiki; Yamauchi, Kazuhiro; Maruyama, Mie; Yasuda, Tadashi; Kohno, Masakazu; Abe, Youichi

    2011-09-01

    In recent years, oxidative stress has been postulated to be an important factor in the pathogenesis and development of lifestyle-related diseases. In this study, we investigated the association between the derivatives of reactive oxygen metabolites (d-ROMs), as an index of products of reactive oxygen species (ROS), and biological antioxidant potential (BAP), as an index of antioxidant potential. We also investigated the associations between d-ROMs or BAP and the risk factors for lifestyle-related diseases or metabolic syndrome-associated factors to evaluate their usefulness in preventive medicine. There were 442 subjects who underwent health checkup examination in our facilities. In addition to standard medical checkup items, we analyzed d-ROMs, BAP, brachial-ankle pulse wave velocity, high-sensitivity C-reactive protein level and visceral fat area (VFA) visualized on a computed tomography scan. The mean d-ROM value in females was significantly higher than that in males. There was a positive correlation between the d-ROM and VFA levels. On correlation analysis, there was a negative correlation between the d-ROM and creatinine levels. As factors that influence d-ROMs, the level of VFA was selected, suggesting the significance of oxidative stress measurement with d-ROMs. In addition, there was a positive correlation between d-ROMs and BAP values. Further research is required to resolve whether increased production of ROS or the antioxidant potential that can compensate for such an increase of ROS is more important in vivo.

  16. Impact of scaling voltage and size on the performance of Side-contacted Field Effect Diode

    NASA Astrophysics Data System (ADS)

    Touchaei, Behnam Jafari; Manavizadeh, Negin

    2018-05-01

    Side-contacted Fild Effect Diode (S-FED), with low leakage current and high Ion/Ioff ratio, has been recently introduced to suppress short channel effects in nanoscale regime. The voltage and size scalability of S-FEDs and effects on the power consumption, propagation delay time, and power delay product have been studied in this article. The most attractive properties are related to channel length to channel thickness ratio in the S-FED which reduces in comparison with MOSFET significantly, while gates control over the channel improve and the off-state current reduces dramatically. This promising advantage is not only capable to improve important S-FED's characteristics such as subthreshold slope but also eliminate Latch-up and floating body effect.

  17. Scalable fabrication of nanostructured devices on flexible substrates using additive driven self-assembly and nanoimprint lithography

    NASA Astrophysics Data System (ADS)

    Watkins, James

    2013-03-01

    Roll-to-roll (R2R) technologies provide routes for continuous production of flexible, nanostructured materials and devices with high throughput and low cost. We employ additive-driven self-assembly to produce well-ordered polymer/nanoparticle hybrid materials that can serve as active device layers, we use highly filled nanoparticle/polymer hybrids for applications that require tailored dielectric constant or refractive index, and we employ R2R nanoimprint lithography for device scale patterning. Specific examples include the fabrication of flexible floating gate memory and large area films for optical/EM management. Our newly constructed R2R processing facility includes a custom designed, precision R2R UV-assisted nanoimprint lithography (NIL) system and hybrid nanostructured materials coaters.

  18. Increased treatment durations lead to greater improvements in non-weight bearing dorsiflexion range of motion for asymptomatic individuals immediately following an anteroposterior grade IV mobilisation of the talus.

    PubMed

    Holland, Christopher James; Campbell, Kevin; Hutt, Kim

    2015-08-01

    Manual therapy aims to minimise pain and restore joint mobility and function. Joint mobilisations are integral to these techniques, with anteroposterior (AP) talocrural joint mobilisations purported to increase dorsiflexion range of motion (DF-ROM). This study aimed to determine whether different treatment durations of single grade IV anteroposterior talocrural joint mobilisations elicit statistically significant differences in DF-ROM. Sixteen asymptomatic male football players (age = 27.1 ± 5.3 years) participated in the study. Non-weight bearing (NWB) and weight bearing (WB) DF-ROM was measured before and after 4 randomised treatment conditions: control treatment, 30 s, 1 min, 2 min. NWB DF-ROM was measured using a universal goniometer, and WB DF-ROM using the weight-bearing lunge test. A within-subjects design was employed so that all participants received each of the treatment conditions. A 4 × 4 balanced Latin square design and 1 week interval between sessions reduced any residual effects. Two-way repeated measures ANOVA revealed a significant improvement in DF-ROM following all AP mobilisation treatments (p < 0.001). The within subjects contrasts showed that increases in treatment duration was associated with statistically significant improvements in DF-ROM (NWB DF-ROM control = 0.01%, 30 s = 14.2%, 1 min = 21.6%, 2 min = 32.8%; WB DF-ROM control = 0.01%, 30 s = 5.0%, 1 min = 7.6%, 2 min = 10.9%; p < 0.05). However, WB DF-ROM improvements were below the minimal detectable change scores needed to conclude that improvements were not a consequence of measurement error. This research shows that single session mobilisations can elicit NWB DF-ROM improvements in asymptomatic individuals in the absence of pain, whilst increases in treatment duration confer greater improvements in NWB DF-ROM within this population. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Risk factors for chronic and recurrent otitis media-a meta-analysis.

    PubMed

    Zhang, Yan; Xu, Min; Zhang, Jin; Zeng, Lingxia; Wang, Yanfei; Zheng, Qing Yin

    2014-01-01

    Risk factors associated with chronic otitis media (COM) and recurrent otitis media (ROM) have been investigated in previous studies. The objective of this study was to integrate the findings and determine the possible risk factors for COM/ROM based on our meta-analysis. A comprehensive search of electronic bibliographic databases (PubMed, Embase, CNKI and Wanfang database) from 1964 to Dec 2012, as well as a manual search of references of articles, was performed. A total of 2971 articles were searched, and 198 full-text articles were assessed for eligibility; 24 studies were eligible for this meta-analysis. Regarding risk factors for COM/ROM, there were two to nine different studies from which the odds ratios (ORs) could be pooled. The presence of allergy or atopy increased the risk of COM/ROM (OR, 1.36; 95% CI, 1.13-1.64; P = 0.001). An upper respiratory tract infection (URTI) significantly increased the risk of COM/ROM (OR, 6.59; 95% CI, 3.13-13.89; P<0.00001). Snoring appeared to be a significant risk factor for COM/ROM (OR, 1.96; 95% CI, 1.78-2.16; P<0.00001). A patient history of acute otitis media (AOM)/ROM increased the risk of COM/ROM (OR, 11.13; 95% CI, 1.06-116.44; P = 0.04). Passive smoke significantly increased the risk of COM/ROM (OR, 1.39; 95% CI, 1.02-1.89 P = 0.04). Low social status appeared to be a risk factor for COM/ROM (OR, 3.82; 95% CI, 1.11-13.15; P = 0.03). Our meta-analysis identified reliable conclusions that allergy/atopy, URTI, snoring, previous history of AOM/ROM, Second-hand smoke and low social status are important risk factors for COM/ROM. Other unidentified risk factors need to be identified in further studies with critical criteria.

  20. Risk Factors for Chronic and Recurrent Otitis Media–A Meta-Analysis

    PubMed Central

    Zhang, Yan; Xu, Min; Zhang, Jin; Zeng, Lingxia; Wang, Yanfei; Zheng, Qing Yin

    2014-01-01

    Risk factors associated with chronic otitis media (COM) and recurrent otitis media (ROM) have been investigated in previous studies. The objective of this study was to integrate the findings and determine the possible risk factors for COM/ROM based on our meta-analysis. A comprehensive search of electronic bibliographic databases (PubMed, Embase, CNKI and Wanfang database) from 1964 to Dec 2012, as well as a manual search of references of articles, was performed. A total of 2971 articles were searched, and 198 full-text articles were assessed for eligibility; 24 studies were eligible for this meta-analysis. Regarding risk factors for COM/ROM, there were two to nine different studies from which the odds ratios (ORs) could be pooled. The presence of allergy or atopy increased the risk of COM/ROM (OR, 1.36; 95% CI, 1.13–1.64; P = 0.001). An upper respiratory tract infection (URTI) significantly increased the risk of COM/ROM (OR, 6.59; 95% CI, 3.13–13.89; P<0.00001). Snoring appeared to be a significant risk factor for COM/ROM (OR, 1.96; 95% CI, 1.78–2.16; P<0.00001). A patient history of acute otitis media (AOM)/ROM increased the risk of COM/ROM (OR, 11.13; 95% CI, 1.06–116.44; P = 0.04). Passive smoke significantly increased the risk of COM/ROM (OR, 1.39; 95% CI, 1.02–1.89 P = 0.04). Low social status appeared to be a risk factor for COM/ROM (OR, 3.82; 95% CI, 1.11–13.15; P = 0.03). Our meta-analysis identified reliable conclusions that allergy/atopy, URTI, snoring, previous history of AOM/ROM, Second-hand smoke and low social status are important risk factors for COM/ROM. Other unidentified risk factors need to be identified in further studies with critical criteria. PMID:24466073

  1. A clocked high-pass-filter-based offset cancellation technique for high-gain biomedical amplifiers

    NASA Astrophysics Data System (ADS)

    Pal, Dipankar; Goswami, Manish

    2010-05-01

    In this article, a simple offset cancellation technique based on a clocked high-pass filter with extremely low output offset is presented. The configuration uses the on-resistance of a complementary metal oxide semiconductor (CMOS) transmission gate (X-gate) and tunes the lower 3-dB cut-off frequency with a matched pair of floating capacitors. The results compare favourably with the more complex auto-zeroing and chopper stabilisation techniques of offset cancellation in terms of power dissipation, component count and bandwidth, while reporting inferior output noise performance. The design is suitable for use in biomedical amplifier systems for applications such as ENG-recording. The system is simulated in Spectre Cadence 5.1.41 using 0.6 μm CMOS technology and the total block gain is ∼83.0 dB while the phase error is <5°. The power consumption is 10.2 mW and the output offset obtained for an input monotone signal of 5 μVpp is 1.28 μV. The input-referred root mean square noise voltage between 1 and 5 kHz is 26.32 nV/√Hz.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vanheusden, K.; Warren, W.L.; Devine, R.A.B.

    It is shown how mobile H{sup +} ions can be generated thermally inside the oxide layer of Si/SiO{sub 2}/Si structures. The technique involves only standard silicon processing steps: the nonvolatile field effect transistor (NVFET) is based on a standard MOSFET with thermally grown SiO{sub 2} capped with a poly-silicon layer. The capped thermal oxide receives an anneal at {approximately}1100 C that enables the incorporation of the mobile protons into the gate oxide. The introduction of the protons is achieved by a subsequent 500-800 C anneal in a hydrogen-containing ambient, such as forming gas (N{sub 2}:H{sub 2} 95:5). The mobile protonsmore » are stable and entrapped inside the oxide layer, and unlike alkali ions, their space-charge distribution can be controlled and rapidly rearranged at room temperature by an applied electric field. Using this principle, a standard MOS transistor can be converted into a nonvolatile memory transistor that can be switched between normally on and normally off. Switching speed, retention, endurance, and radiation tolerance data are presented showing that this non-volatile memory technology can be competitive with existing Si-based non-volatile memory technologies such as the floating gate technologies (e.g. Flash memory).« less

  3. Design Methodology of an Equalizer for Unipolar Non Return to Zero Binary Signals in the Presence of Additive White Gaussian Noise Using a Time Delay Neural Network on a Field Programmable Gate Array

    PubMed Central

    Pérez Suárez, Santiago T.; Travieso González, Carlos M.; Alonso Hernández, Jesús B.

    2013-01-01

    This article presents a design methodology for designing an artificial neural network as an equalizer for a binary signal. Firstly, the system is modelled in floating point format using Matlab. Afterward, the design is described for a Field Programmable Gate Array (FPGA) using fixed point format. The FPGA design is based on the System Generator from Xilinx, which is a design tool over Simulink of Matlab. System Generator allows one to design in a fast and flexible way. It uses low level details of the circuits and the functionality of the system can be fully tested. System Generator can be used to check the architecture and to analyse the effect of the number of bits on the system performance. Finally the System Generator design is compiled for the Xilinx Integrated System Environment (ISE) and the system is described using a hardware description language. In ISE the circuits are managed with high level details and physical performances are obtained. In the Conclusions section, some modifications are proposed to improve the methodology and to ensure portability across FPGA manufacturers.

  4. Altered Knee and Ankle Kinematics During Squatting in Those With Limited Weight-Bearing–Lunge Ankle-Dorsiflexion Range of Motion

    PubMed Central

    Dill, Karli E.; Begalle, Rebecca L.; Frank, Barnett S.; Zinder, Steven M.; Padua, Darin A.

    2014-01-01

    Context: Ankle-dorsiflexion (DF) range of motion (ROM) may influence movement variables that are known to affect anterior cruciate ligament loading, such as knee valgus and knee flexion. To our knowledge, researchers have not studied individuals with limited or normal ankle DF-ROM to investigate the relationship between those factors and the lower extremity movement patterns associated with anterior cruciate ligament injury. Objective: To determine, using 2 different measurement techniques, whether knee- and ankle-joint kinematics differ between participants with limited and normal ankle DF-ROM. Design: Cross-sectional study. Setting: Sports medicine research laboratory. Patients or Other Participants: Forty physically active adults (20 with limited ankle DF-ROM, 20 with normal ankle DF-ROM). Main Outcome Measure(s): Ankle DF-ROM was assessed using 2 techniques: (1) nonweight-bearing ankle DF-ROM with the knee straight, and (2) weight-bearing lunge (WBL). Knee flexion, knee valgus-varus, knee internal-external rotation, and ankle DF displacements were assessed during the overhead-squat, single-legged squat, and jump-landing tasks. Separate 1-way analyses of variance were performed to determine whether differences in knee- and ankle-joint kinematics existed between the normal and limited groups for each assessment. Results: We observed no differences between the normal and limited groups when classifying groups based on nonweight-bearing passive-ankle DF-ROM. However, individuals with greater ankle DF-ROM during the WBL displayed greater knee-flexion and ankle-DF displacement and peak knee flexion during the overhead-squat and single-legged squat tasks. In addition, those individuals also demonstrated greater knee-varus displacement during the single-legged squat. Conclusions: Greater ankle DF-ROM assessed during the WBL was associated with greater knee-flexion and ankle-DF displacement during both squatting tasks as well as greater knee-varus displacement during the single-legged squat. Assessment of ankle DF-ROM using the WBL provided important insight into compensatory movement patterns during squatting, whereas nonweight-bearing passive ankle DF-ROM did not. Improving ankle DF-ROM during the WBL may be an important intervention for altering high-risk movement patterns commonly associated with noncontact anterior cruciate ligament injury. PMID:25144599

  5. Altered knee and ankle kinematics during squatting in those with limited weight-bearing-lunge ankle-dorsiflexion range of motion.

    PubMed

    Dill, Karli E; Begalle, Rebecca L; Frank, Barnett S; Zinder, Steven M; Padua, Darin A

    2014-01-01

    Ankle-dorsiflexion (DF) range of motion (ROM) may influence movement variables that are known to affect anterior cruciate ligament loading, such as knee valgus and knee flexion. To our knowledge, researchers have not studied individuals with limited or normal ankle DF-ROM to investigate the relationship between those factors and the lower extremity movement patterns associated with anterior cruciate ligament injury. To determine, using 2 different measurement techniques, whether knee- and ankle-joint kinematics differ between participants with limited and normal ankle DF-ROM. Cross-sectional study. Sports medicine research laboratory. Forty physically active adults (20 with limited ankle DF-ROM, 20 with normal ankle DF-ROM). Ankle DF-ROM was assessed using 2 techniques: (1) nonweight-bearing ankle DF-ROM with the knee straight, and (2) weight-bearing lunge (WBL). Knee flexion, knee valgus-varus, knee internal-external rotation, and ankle DF displacements were assessed during the overhead-squat, single-legged squat, and jump-landing tasks. Separate 1-way analyses of variance were performed to determine whether differences in knee- and ankle-joint kinematics existed between the normal and limited groups for each assessment. We observed no differences between the normal and limited groups when classifying groups based on nonweight-bearing passive-ankle DF-ROM. However, individuals with greater ankle DF-ROM during the WBL displayed greater knee-flexion and ankle-DF displacement and peak knee flexion during the overhead-squat and single-legged squat tasks. In addition, those individuals also demonstrated greater knee-varus displacement during the single-legged squat. Greater ankle DF-ROM assessed during the WBL was associated with greater knee-flexion and ankle-DF displacement during both squatting tasks as well as greater knee-varus displacement during the single-legged squat. Assessment of ankle DF-ROM using the WBL provided important insight into compensatory movement patterns during squatting, whereas nonweight-bearing passive ankle DF-ROM did not. Improving ankle DF-ROM during the WBL may be an important intervention for altering high-risk movement patterns commonly associated with noncontact anterior cruciate ligament injury.

  6. The effect of the remplissage procedure on shoulder range of motion: a cadaveric study.

    PubMed

    Omi, Rei; Hooke, Alexander W; Zhao, Kristin D; Matsuhashi, Tomoya; Goto, Akira; Yamamoto, Nobuyuki; Sperling, John W; Steinmann, Scott P; Itoi, Eiji; An, Kai-Nan

    2014-02-01

    The purpose of this in vitro biomechanical study was to assess the effects of the remplissage procedure for small- and large-sized Hill-Sachs lesions (HSLs) on shoulder range of motion (ROM) with a special interest in the apprehension position. HSLs of 50% and 100% of the glenoid width were simulated in 7 cadaveric shoulders as small and large lesions, respectively, and the postoperative condition was reproduced by placing suture anchors on the articular surface and tying down the infraspinatus at the medial edge of the would-be lesion site. ROMs were measured in abduction, internal rotation, and external rotation with the humerus in the adducted and abducted position. In addition, the ROM was measured in the anterior apprehension position, in which 2 torques of external rotation and extension were applied simultaneously, and external rotation and horizontal extension ROMs were measured with the humerus in different abduction angles (20°, 40°, and 60°). For standard ROMs, the procedure for the 50% HSL maintained complete ROMs, whereas the procedure for the 100% HSL significantly decreased external rotation ROM with the humerus in both the adducted and abducted positions, as well as abduction ROM. In the apprehension position, remplissage for the 50% HSL decreased extension ROM with the humerus abducted to 40° and 60°. Remplissage for the 100% HSL significantly decreased both external and extension ROMs regardless of the humeral abduction angle. In the cadaveric model with an intact humeral head and the simulated postoperative condition, the remplissage procedure for a large HSL caused significant restrictions in ROM of abduction in the scapular plane and external rotation with the humerus in both adduction and abduction. It also caused significant restrictions in both external rotation and extension ROMs in the apprehension position. The indication for the remplissage procedure for the larger HSL should be considered carefully, especially for the competitive throwing athlete who needs exceptional external rotation ROM for optimal overhead throwing performance. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  7. Integrating CD-ROM with Printed and Online Services: A Silver Platter End-User Perspective.

    ERIC Educational Resources Information Center

    Bezanson, Deborah

    1987-01-01

    Discusses the George Washington University Library's experiences as a test site for Silver Platter/Psychlit. Advantages of the CD-ROM concept, including visibility, accessibility, costs, and sophistication, are noted; crucial issues in deciding whether to acquire a CD-ROM product are considered; and CD-ROM is described as a means for integrating…

  8. Census, CD-ROM, and You! New Horizons for Microcomputer Users of Census Bureau Data.

    ERIC Educational Resources Information Center

    Bureau of the Census (DOC), Washington, DC. Data User Services Div.

    This introductory guide to Census Bureau data that is currently available to microcomputer users on compact disc (CD-ROM) begins by explaining the types of information available, how CD-ROM works, and the hardware and software required to access the databases using a microcomputer. Descriptions of data currently available on CD-ROM include…

  9. 47 CFR 61.22 - Composition of tariffs.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    .../2 inch (8.89 cm) diskette, or a 5 inch CD-ROM, formatted in an IBM-compatible form using either Word... tariff. The diskette or CD-ROM must be submitted in “read only” mode. The diskette or CD-ROM must be... multiple diskettes or CD-ROMs are submitted, the issuing carrier shall clearly label each diskette in the...

  10. CD-ROM Multimodal Affordances: Classroom Interaction Perspectives in the Malaysian English Literacy Hour

    ERIC Educational Resources Information Center

    Gardner, Sheena; Yaacob, Aizan

    2009-01-01

    CD-ROM affordances are explored in this article through participation in classroom interaction. CD-ROMs for shared reading of animated stories and language work were introduced to all Malaysian primary schools in 2003 for the Year 1 English Literacy Hour. We present classroom interaction extracts that show how the same CD-ROMs offer different…

  11. Oxidative stress, d-ROMs test, and ceruloplasmin.

    PubMed

    Colombini, Francesco; Carratelli, Mauro; Alberti, Angelo

    2016-01-01

    Human serum samples were evaluated for oxidative stress with the d-ROMs test. The ceruloplasmin (CP) and copper contents of the samples was independently measured and compared to those calculated on the basis of the d-ROMs test results for pure CP solutions. The d-ROMs readings did not show any significant correlation with either the CP or copper contents of the samples. Critical interference of CP on the d-ROMs test was therefore excluded and the usefulness of the test in the evaluation of global oxidative status of a biological sample could be reassessed.

  12. CAI System of Obunsha Co., Ltd. Using CD-ROM

    NASA Astrophysics Data System (ADS)

    Todokoro, Shigeru; Mukai, Yoshihiro

    This paper introduces the present status of R & D on CAI teaching materials in Obunsha Co., Ltd. Characteristics of CAI using CD-ROM as well as Culture-in CAI Teaching Materials System for junior high school English are described. The system consists of CD-ROM driver XM-2000 and Pasopia 700 of Toshiba Corporation having both features of CD-ROM and FD. CD-ROM stores vast amount of voice data while FD does text and graphics data. It is a frame-oriented mode system enabling to raise learning effect.

  13. Fish elevator and method of elevating fish

    DOEpatents

    Truebe, Jonathan; Drooker, Michael S.

    1984-01-01

    A means and method for transporting fish from a lower body of water to a higher body of water. The means comprises a tubular lock with a gated entrance below the level of the lower body of water through which fish may enter the lock and a discharge passage above the level of the upper body of water. The fish raising means in the lock is a crowder pulled upward by a surface float as water from the upper body of water gravitationally flows into the closed lock filling it to the level of the upper body. Water is then pumped into the lock to raise the level to the discharge passage. The crowder is then caused to float upward the remaining distance through the water to the level of the discharge passage by the introduction of air into a pocket on the underside of the crowder. The fish are then automatically discharged from the lock into the discharge passage by the out of water position of the crowder. The movement of the fish into the discharge passage is aided by the continuous overflow of water still being pumped into the lock. A pipe may be connected to the discharge passage to deliver the fish to a selected location in the upper body of water.

  14. A Trichomonas vaginalis Rhomboid Protease and Its Substrate Modulate Parasite Attachment and Cytolysis of Host Cells

    PubMed Central

    Riestra, Angelica M.; Gandhi, Shiv; Sweredoski, Michael J.; Moradian, Annie; Hess, Sonja; Urban, Sinisa; Johnson, Patricia J.

    2015-01-01

    Trichomonas vaginalis is an extracellular eukaryotic parasite that causes the most common, non-viral sexually transmitted infection worldwide. Although disease burden is high, molecular mechanisms underlying T. vaginalis pathogenesis are poorly understood. Here, we identify a family of putative T. vaginalis rhomboid proteases and demonstrate catalytic activity for two, TvROM1 and TvROM3, using a heterologous cell cleavage assay. The two T. vaginalis intramembrane serine proteases display different subcellular localization and substrate specificities. TvROM1 is a cell surface membrane protein and cleaves atypical model rhomboid protease substrates, whereas TvROM3 appears to localize to the Golgi apparatus and recognizes a typical model substrate. To identify TvROM substrates, we interrogated the T. vaginalis surface proteome using both quantitative proteomic and bioinformatic approaches. Of the nine candidates identified, TVAG_166850 and TVAG_280090 were shown to be cleaved by TvROM1. Comparison of amino acid residues surrounding the predicted cleavage sites of TvROM1 substrates revealed a preference for small amino acids in the predicted transmembrane domain. Over-expression of TvROM1 increased attachment to and cytolysis of host ectocervical cells. Similarly, mutations that block the cleavage of a TvROM1 substrate lead to its accumulation on the cell surface and increased parasite adherence to host cells. Together, these data indicate a role for TvROM1 and its substrate(s) in modulating attachment to and lysis of host cells, which are key processes in T. vaginalis pathogenesis. PMID:26684303

  15. The influence of variable range of motion training on neuromuscular performance and control of external loads.

    PubMed

    Clark, Ross A; Humphries, Brendan; Hohmann, Erik; Bryant, Adam L

    2011-03-01

    Resistance training programs that emphasize high force production in different regions of the range of motion (ROM) may provide performance benefits. This study examined whether variable ROM (VROM) training, which consists of partial ROM training with countermovements performed in a different phase of the ROM for each set, results in improved functional performance. Twenty-two athletes (age 22.7 ± 2.4 years, height 1.81 ± 0.07 m, and body mass 94.6 ± 14.5 kg) with extensive resistance training backgrounds performed either a VROM or full ROM control (CON) 5-week, concentric work-matched training program. The participants were assigned to a group based on stratified randomization incorporating their strength levels and performance gains in preceding training microcycles. Testing consisted of assessing the force-ROM relationship during isokinetic and isometric bench press and ballistic bench throws, with normalized electromyography amplitude assessed during the isometric tests. Repeated-measure analyses of variance revealed that the VROM intervention significantly (p < 0.05) increased both full ROM bench throw displacement (+15.5%) and half ROM bench throw peak force (+15.7%), in addition to isokinetic peak force in the terminal ROM (13.5% increase). No significant differences were observed in the CON group or between groups for any other outcome measures. Analysis of the force-ROM relationship revealed that that the VROM intervention enhanced performance at shorter muscle lengths. These findings suggest that VROM training improves terminal and midrange performance gains, resulting in the athlete possessing an improved ability to control external loading and produce dynamic force.

  16. Energy balance and mass conservation in reduced order models of fluid flows

    NASA Astrophysics Data System (ADS)

    Mohebujjaman, Muhammad; Rebholz, Leo G.; Xie, Xuping; Iliescu, Traian

    2017-10-01

    In this paper, we investigate theoretically and computationally the conservation properties of reduced order models (ROMs) for fluid flows. Specifically, we investigate whether the ROMs satisfy the same (or similar) energy balance and mass conservation as those satisfied by the Navier-Stokes equations. All of our theoretical findings are illustrated and tested in numerical simulations of a 2D flow past a circular cylinder at a Reynolds number Re = 100. First, we investigate the ROM energy balance. We show that using the snapshot average for the centering trajectory (which is a popular treatment of nonhomogeneous boundary conditions in ROMs) yields an incorrect energy balance. Then, we propose a new approach, in which we replace the snapshot average with the Stokes extension. Theoretically, the Stokes extension produces an accurate energy balance. Numerically, the Stokes extension yields more accurate results than the standard snapshot average, especially for longer time intervals. Our second contribution centers around ROM mass conservation. We consider ROMs created using two types of finite elements: the standard Taylor-Hood (TH) element, which satisfies the mass conservation weakly, and the Scott-Vogelius (SV) element, which satisfies the mass conservation pointwise. Theoretically, the error estimates for the SV-ROM are sharper than those for the TH-ROM. Numerically, the SV-ROM yields significantly more accurate results, especially for coarser meshes and longer time intervals.

  17. The Market Place: An Internal View of the Future of CD-ROM--The Perspective of the H. W. Wilson Company.

    ERIC Educational Resources Information Center

    Miller, Frank W.; Loeding, Deborah Voigt

    1989-01-01

    Discussion of technological developments in library reference services focuses on contributions of the H. W. Wilson Company and highlights CD-ROM technology. Topics discussed include online access; menu-driven systems; CD-ROM hardware and software concerns; user response to CD-ROM; quality control of databases; pricing considerations; and future…

  18. Educational use of World Wide Web pages on CD-ROM.

    PubMed

    Engel, Thomas P; Smith, Michael

    2002-01-01

    The World Wide Web is increasingly important for medical education. Internet served pages may also be used on a local hard disk or CD-ROM without a network or server. This allows authors to reuse existing content and provide access to users without a network connection. CD-ROM offers several advantages over network delivery of Web pages for several applications. However, creating Web pages for CD-ROM requires careful planning. Issues include file names, relative links, directory names, default pages, server created content, image maps, other file types and embedded programming. With care, it is possible to create server based pages that can be copied directly to CD-ROM. In addition, Web pages on CD-ROM may reference Internet served pages to provide the best features of both methods.

  19. Technology Applications Group Multimedia CD-ROM Project

    NASA Technical Reports Server (NTRS)

    McRacken, Kristi D.

    1995-01-01

    To produce a multimedia CD-ROM for the Technology Applications Group which would present the Technology Opportunity Showcase (TOPS) exhibits and Small Business Innovative Research (SBIR) projects to interested companies. The CD-ROM format is being used and developed especially for those companies who do not have Internet access, and cannot directly visit Langley through the World Wide Web. The CD-ROM will include text, pictures, sound, and movies. The information for the CD-ROM will be stored in a database from which the users can query and browse the information, and future CD's can be maintained and updated.

  20. Use of CD-ROM MEDLINE by medical students of the College of Medicine, University of Lagos, Nigeria.

    PubMed

    Ogunyade, Taiwo O; Oyibo, Wellington A

    2003-01-01

    Use of information technology in information acquisition, especially MEDLINE on CD-ROM and online, has been evaluated in several localities and regions, especially in the advanced countries. Use of MEDLINE on CD-ROM is still very poor among the medical students of the University of Lagos, Lagos, Nigeria, due to lack of awareness, insufficient personal computers, nonperiodic training, and the high cost of using the facility. Due to financial constraints, MEDLINE online and sufficiently-networked computer systems are not available. To report on the situation in Nigeria, a developing country, so as to compare the current awareness of searching MEDLINE on CD-ROM among the medical students at the University of Lagos with the awareness of their overseas' counterparts. This is the first step toward setting up an online PubMed search as well as expanding the computer systems and network. Essentially based on cross-sectional proportional sampling using structured questionnaires, in-depth interviews, and focus-group discussions among the medical students and library staff. The study involved the medical students in their second year to sixth (final) year of study. Of the 250 students interviewed, 130 (52%) were aware of MEDLINE on CD-ROM searches as a means of information retrieval. Only 60 (24%) had used MEDLINE on CD-ROM-2% had used MEDLINE on CD-ROM more than 9 times; 4%, 7 to 9 times; 8%, 4 to 6 times; and 10%, 1 to 3 times. Of the students who used MEDLINE on CD-ROM search, 22% used it in preparing for examinations, 24% in research, 6% in patient care, and 26% in preparation of assignments and clinical cases. Lack of awareness (52%) and cost of undertaking MEDLINE on CD-ROM search (46%) were identified as important factors that discouraged the use of MEDLINE on CD-ROM. Though the above factors were recognized as important, it was concluded that the reasons for the poor use of MEDLINE on CD-ROM are multifactorial. Poor use of MEDLINE on CD-ROM could be attributed to these critical underlying factors: nonavailability of networked personal computers, which should be connected to a central server; lack of mandatory assignments to the medical students that would specifically require use of MEDLINE on CD-ROM; financial constraints on the university management; and infrequent periodic orientation on use of MEDLINE on CD-ROM. It was therefore suggested that the number of personal computers should be increased and that the library staff should periodically train the preclinical and clinical medical students in searching MEDLINE on CD-ROM. These steps would enable the medical students to benefit from online PubMed searching when it becomes fully operational in the future.

  1. Position of the prosthesis and the incidence of dislocation following total hip replacement.

    PubMed

    He, Rong-xin; Yan, Shi-gui; Wu, Li-dong; Wang, Xiang-hua; Dai, Xue-song

    2007-07-05

    Dislocation is the second most common complication of hip replacement surgery, and impact of the prosthesis is believed to be the fundamental reason. The present study employed Solidworks 2003 and MSC-Nastran software to analyze the three dimensional variables in order to investigate how to prevent dislocation following hip replacement surgery. Computed tomography (CT) imaging was used to collect femoral outline data and Solidworks 2003 software was used to construct the cup model with variabilities. Nastran software was used to evaluate dislocation at different prosthesis positions and different geometrical shapes. Three dimensional movement and results from finite element method were analyzed and the values of dislocation resistance index (DRI), range of motion to impingement (ROM-I), range of motion to dislocation (ROM-D) and peak resisting moment (PRM) were determined. Computer simulation was used to evaluate the range of motion of the hip joint at different prosthesis positions. Finite element analysis showed: (1) Increasing the ratio of head/neck increased the ROM-I values and moderately increased ROM-D and PRM values. Increasing the head size significantly increased PRM and to some extent ROM-I and ROM-D values, which suggested that there would be a greater likelihood of dislocation. (2) Increasing the anteversion angle increased the ROM-I, ROM-D, PRM, energy required for dislocation (ENERGY-D) and DRI values, which would increase the stability of the joint. (3) As the chamber angle was increased, ROM-I, ROM-D, PRM, Energy-D and DRI values were increased, resulting in improved joint stability. Chamber angles exceeding 55 degrees resulted in increases in ROM-I and ROM-D values, but decreases in PRM, Energy-D, and DRI values, which, in turn, increased the likelihood of dislocation. (4) The cup, which was reduced posteriorly, reduced ROM-I values (2.1 -- 5.3 degrees ) and increased the DRI value (0.073). This suggested that the posterior high side had the effect of 10 degrees anteversion angle. Increasing the head/neck ratio increases joint stability. Posterior high side reduced the range of motion of the joint but increased joint stability; Increasing the anteversion angle increases DRI values and thus improve joint stability; Increasing the chamber angle increases DRI values and improves joint stability. However, at angles exceeding 55 degrees , further increases in the chamber angle result in decreased DRI values and reduce the stability of the joint.

  2. Kino'jib'alil ri Qati't Qamam--El Pensamiento de Nuestros Abuelos (Our Grandparents' Thinking). [CD-ROM].

    ERIC Educational Resources Information Center

    Academy for Educational Development, Washington, DC.

    This CD-ROM is part of an interactive and dynamic multimedia package of information and games for learning K'iche' and Ixil. Groups of students from each of the four teacher training schools re-enacted various Mayan traditions and documented them in this multimedia CD-ROM. The following presentations are included on the CD-ROM: Uxe'al nutinamit…

  3. Biomechanics of unilateral and bilateral sacroiliac joint stabilization: laboratory investigation.

    PubMed

    Lindsey, Derek P; Parrish, Robin; Gundanna, Mukund; Leasure, Jeremi; Yerby, Scott A; Kondrashov, Dimitriy

    2018-03-01

    OBJECTIVE Bilateral symptoms have been reported in 8%-35% of patients with sacroiliac (SI) joint dysfunction. Stabilization of a single SI joint may significantly alter the stresses on the contralateral SI joint. If the contralateral SI joint stresses are significantly increased, degeneration may occur; alternatively, if the stresses are significantly reduced, bilateral stabilization may be unnecessary for patients with bilateral symptoms. The biomechanical effects of 1) unilateral stabilization on the contralateral SI joint and 2) bilateral stabilization on both SI joints are currently unknown. The objectives of this study were to characterize bilateral SI joint range of motion (ROM) and evaluate and compare the biomechanical effects of unilateral and bilateral implant placement for SI joint fusion. METHODS A lumbopelvic model (L5-pelvis) was used to test the ROM of both SI joints in 8 cadavers. A single-leg stance setup was used to load the lumbar spine and measure the ROM of each SI joint in flexion-extension, lateral bending, and axial rotation. Both joints were tested 1) while intact, 2) after unilateral stabilization, and 3) after bilateral stabilization. Stabilization consisted of lateral transiliac placement of 3 triangular titanium plasma-sprayed (TPS) implants. RESULTS Intact testing showed that during single-leg stance the contralateral SI joint had less ROM in flexion-extension (27%), lateral bending (32%), and axial rotation (69%) than the loaded joint. Unilateral stabilization resulted in significant reduction of flexion-extension ROM (46%) on the treated side; no significant ROM changes were observed for the nontreated side. Bilateral stabilization resulted in significant reduction of flexion-extension ROM of the primary (45%) and secondary (75%) SI joints. CONCLUSIONS This study demonstrated that during single-leg loading the ROMs for the stance (loaded) and swing (unloaded) SI joints are significantly different. Unilateral stabilization for SI joint dysfunction significantly reduces the ROM of the treated side, but does not significantly reduce the ROM of the nontreated contralateral SI joint. Bilateral stabilization is necessary to significantly reduce the ROM for both SI joints.

  4. Ankle-Dorsiflexion Range of Motion and Landing Biomechanics

    PubMed Central

    Fong, Chun-Man; Blackburn, J. Troy; Norcross, Marc F.; McGrath, Melanie; Padua, Darin A.

    2011-01-01

    Abstract Context: A smaller amount of ankle-dorsiflexion displacement during landing is associated with less knee-flexion displacement and greater ground reaction forces, and greater ground reaction forces are associated with greater knee-valgus displacement. Additionally, restricted dorsiflexion range of motion (ROM) is associated with greater knee-valgus displacement during landing and squatting tasks. Because large ground reaction forces and valgus displacement and limited knee-flexion displacement during landing are anterior cruciate ligament (ACL) injury risk factors, dorsiflexion ROM restrictions may be associated with a greater risk of ACL injury. However, it is unclear whether clinical measures of dorsiflexion ROM are associated with landing biomechanics. Objective: To evaluate relationships between dorsiflexion ROM and landing biomechanics. Design: Descriptive laboratory study. Setting: Research laboratory. Patients or Other Participants: Thirty-five healthy, physically active volunteers. Intervention(s): Passive dorsiflexion ROM was assessed under extended-knee and flexed-knee conditions. Landing biomechanics were assessed via an optical motion-capture system interfaced with a force plate. Main Outcome Measure(s): Dorsiflexion ROM was measured in degrees using goniometry. Knee-flexion and knee-valgus displacements and vertical and posterior ground reaction forces were calculated during the landing task. Simple correlations were used to evaluate relationships between dorsiflexion ROM and each biomechanical variable. Results: Significant correlations were noted between extended-knee dorsiflexion ROM and knee-flexion displacement (r  =  0.464, P  =  .029) and vertical (r  =  −0.411, P  =  .014) and posterior (r  =  −0.412, P  =  .014) ground reaction forces. All correlations for flexed-knee dorsiflexion ROM and knee-valgus displacement were nonsignificant. Conclusions: Greater dorsiflexion ROM was associated with greater knee-flexion displacement and smaller ground reaction forces during landing, thus inducing a landing posture consistent with reduced ACL injury risk and limiting the forces the lower extremity must absorb. These findings suggest that clinical techniques to increase plantar-flexor extensibility and dorsiflexion ROM may be important additions to ACL injury-prevention programs. PMID:21214345

  5. Shoulder-Rotator Strength, Range of Motion, and Acromiohumeral Distance in Asymptomatic Adolescent Volleyball Attackers

    PubMed Central

    Harput, Gulcan; Guney, Hande; Toprak, Ugur; Kaya, Tunca; Colakoglu, Fatma Filiz; Baltaci, Gul

    2016-01-01

    Context: Sport-specific adaptations at the glenohumeral joint could occur in adolescent athletes because they start participating in high-performance sports in early childhood. Objective: To investigate shoulder-rotator strength, internal-rotation (IR) and external-rotation (ER) range of motion (ROM), and acromiohumeral distance (AHD) in asymptomatic adolescent volleyball attackers to determine if they have risk factors for injury. Design: Cross-sectional study. Setting: University laboratory. Participants: Thirty-nine adolescent high school-aged volleyball attackers (22 boys, 17 girls; age = 16.0 ± 1.4 years, height = 179.2 ± 9.0 cm, mass = 67.1 ± 10.9 kg, body mass index = 20.7 ± 2.6 kg/m2). Main Outcome Measure(s): Shoulder IR and ER ROM, total-rotation ROM, glenohumeral IR deficit, AHD, and concentric and eccentric strength of the shoulder internal and external rotators were tested bilaterally. Results: External-rotation ROM was greater (t38 = 4.92, P < .001), but IR ROM (t38 = −8.61, P < .001) and total ROM (t38 = −3.55, P = .01) were less in the dominant shoulder, and 15 athletes had a glenohumeral IR deficit (IR ROM loss > 18°). We observed greater concentric internal-rotator (t38 = 2.89, P = .006) and eccentric external-rotator (t38 = 2.65, P = .01) strength in the dominant than in the nondominant shoulder. The AHD was less in the dominant shoulder (t38 = −3.60, P < .001). Conclusions: Adolescent volleyball attackers demonstrated decreased IR ROM, total ROM, and AHD and increased ER ROM in their dominant shoulder. Therefore, routine screening of adolescent athletes and designing training programs for hazardous adaptive changes could be important in preventing shoulder injuries. PMID:27813683

  6. Shoulder-Rotator Strength, Range of Motion, and Acromiohumeral Distance in Asymptomatic Adolescent Volleyball Attackers.

    PubMed

    Harput, Gulcan; Guney, Hande; Toprak, Ugur; Kaya, Tunca; Colakoglu, Fatma Filiz; Baltaci, Gul

    2016-09-01

    Sport-specific adaptations at the glenohumeral joint could occur in adolescent athletes because they start participating in high-performance sports in early childhood. To investigate shoulder-rotator strength, internal-rotation (IR) and external-rotation (ER) range of motion (ROM), and acromiohumeral distance (AHD) in asymptomatic adolescent volleyball attackers to determine if they have risk factors for injury. Cross-sectional study. University laboratory. Thirty-nine adolescent high school-aged volleyball attackers (22 boys, 17 girls; age = 16.0 ± 1.4 years, height = 179.2 ± 9.0 cm, mass = 67.1 ± 10.9 kg, body mass index = 20.7 ± 2.6 kg/m 2 ). Shoulder IR and ER ROM, total-rotation ROM, glenohumeral IR deficit, AHD, and concentric and eccentric strength of the shoulder internal and external rotators were tested bilaterally. External-rotation ROM was greater (t 38 = 4.92, P < .001), but IR ROM (t 38 = -8.61, P < .001) and total ROM (t 38 = -3.55, P = .01) were less in the dominant shoulder, and 15 athletes had a glenohumeral IR deficit (IR ROM loss > 18°). We observed greater concentric internal-rotator (t 38 = 2.89, P = .006) and eccentric external-rotator (t 38 = 2.65, P = .01) strength in the dominant than in the nondominant shoulder. The AHD was less in the dominant shoulder (t 38 = -3.60, P < .001). Adolescent volleyball attackers demonstrated decreased IR ROM, total ROM, and AHD and increased ER ROM in their dominant shoulder. Therefore, routine screening of adolescent athletes and designing training programs for hazardous adaptive changes could be important in preventing shoulder injuries.

  7. Impact of straight, unconnected, radially-oriented, and tapered mesopores on column efficiency: A theoretical investigation.

    PubMed

    Gritti, Fabrice

    2017-02-17

    Superficially porous particles (SPPs) can be prepared from a pseudomorphic transformation (PMT) which produces straight, unconnected, and radially-oriented mesopores (ROMs). ROMs can be either both ends open in fully porous particles (FPPs) or one-end-closed in SPPs. The impact of ROMs on the longitudinal diffusion (B/u), solid-liquid mass transfer resistance (C s u), and on the eddy dispersion (A(u)) height equivalent to a theoretical plate (HETP) of 3D randomly packed columns was investigated based on theoretical viewpoints. Torquato's theory of effective diffusion in packed beds (B term), Giddings' coupling theory of eddy dispersion (A term), and Giddings' generalized nonequilibrium theory (C s term) are applied to make predictions. First, it is found that the A term is nearly independent on the internal structure of the particle. Secondly, in the absence of flow, infinitely narrow and both ends open (no constriction effect) ROMs induce an internal hindrance factor of 23 regarding diffusion along the axial direction. Experimental data reveal that one-end-closed and 80Å wide ROMs in SPPs lead to a measurable internal hindrance factor of 27 regarding diffusion in the porous shell. Thirdly, above the optimum speed, the C s coefficient is dependent on the geometry (cylinders, cones, etc.) of the ROMs: when ROMs are conical in SPPs, C s is expected to decrease by 80% with respect to cylindrical ROMs. From an application perspective, PMT-SPPs prepared with narrow ROMs are well suited for the analysis of small molecules at or below optimum speed (lowest B term) while PMT-SPPs made of wide and conical ROMs are ideal for the analysis of large molecules above optimum speed (smallest C s term). Copyright © 2017. Published by Elsevier B.V.

  8. Relations between serum reactive oxygen metabolites (ROMs) and various inflammatory and metabolic parameters in a Japanese population.

    PubMed

    Hirose, Hiroshi; Kawabe, Hiroshi; Komiya, Naoko; Saito, Ikuo

    2009-04-01

    Both oxidative stress and inflammation are known to play roles in the pathogenesis of cardiovascular disease. We investigated the relations between reactive oxygen metabolites (ROMs) and various inflammatory and metabolic parameters in a Japanese population. We analyzed 48 male and 69 female subjects, aged 25 to 65 years, who underwent an annual health checkup in our university. Serum ROM level was assayed using a free radical elective evaluator. We also measured serum concentrations of high-sensitivity C-reactive protein (hsCRP), insulin, and high molecular weight (HMW) adiponectin. Although the serum ROM level in females (347+/-83 Carr U) was slightly higher than in males (333+/-53 Carr U), this was not statistically significant. In the 48 male subjects, the ROM level negatively correlated with age (r=-0.344, p=0.0161), and positively correlated with the hsCRP level (r=0.306, p=0.0338). In the 69 female subjects, the ROM level negatively correlated with serum creatinine (r=-0.293, p=0.0141), and positively correlated with insulin (r=0.278, p=0.0202), the insulin resistance index (r=0.286, p=0.0170) and hsCRP levels (r=0.487, p<0.0001). Stepwise multiple regression analysis revealed that serum hsCRP, creatinine, and age were independently correlated with the serum ROMs level (R2=0.365; F value highest for hsCRP). When the study subjects were divided into tertiles according to the ROM level, serum hsCRP was significantly different among the three groups: its level was highest in the highest tertile of ROMs (p<0.001). These results suggest that the serum ROM level is closely associated with serum hsCRP in Japanese adult subjects.

  9. Evaluation of constipation in older adults: radioopaque markers (ROMs) versus wireless motility capsule (WMC).

    PubMed

    Rao, S S C; Coss-Adame, E; Valestin, J; Mysore, K

    2012-01-01

    There is scarce information regarding assessment of constipation in older subjects. We examined regional and whole-gut transit time (WGTT) with wireless motility capsule (WMC) and compared this with radioopaque markers (ROM) transit. 39 constipated and 11 healthy older subjects (≥ 65 years) ingested a ROM capsule and WMC, wore a data receiver and kept stool diaries for 5 days. WMC recordings were analyzed for colonic transit time (CTT), WGTT and gastric emptying time (GET). Radiographs obtained on day 5 assessed ROM transit. Results for each device were compared. The CTT (p = <0.0001), WGTT (p = <0.001) and GET (p = <0.04) as measured by WMC were all slower in constipated subjects compared to healthy subjects. ROM colonic transit was also slower (p = <0.007) in constipated compared to healthy subjects. The diagnostic utility for identifying subjects with constipation as assessed by receiver operating characteristics were similar; 0.85 (WMC) versus 0.73 (ROM). Device agreement for slow colonic transit was 88% with good correlation between WMC and ROM (CTT r=0.718, p=0.0001, WGTT r=0.693, p=0.0001). Slow transit constipation was identified in 28% with ROM and 32% with WMC. No adverse events were recorded. WMC is a safe and useful device that provides objective diagnosis of delayed colonic and whole gut transit in older constipated adults. It is a radiation-free, physiologic and ambulatory technique that provides additional diagnostic information than ROM. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  10. Long saphenous vein stripping reduces local level of reactive oxygen metabolites in patients with varicose disease of the lower limbs.

    PubMed

    Flore, Roberto; Santoliquido, Angelo; Antonio, Dal Lago; Pola, Enrico; Flex, Andrea; Pola, Roberto; Muzi, Marco Gallinella; Farinon, Attilio; Rulli, Francesco; Gaetani, Eleonora; Tondi, Paolo; Gerardino, Laura; Gasbarrini, Antonio

    2003-04-01

    Long saphenous vein (LSV) stripping is the most common surgical procedure in patients affected by varicose disease of the lower limbs. Reactive oxygen metabolites (ROM) generation plays a crucial role in chronic venous insufficiency (CVI). The aim of this study was to investigate whether ROM generation is increased in patients affected by varicose disease versus healthy controls and whether LSV stripping has a positive effect on the local production of ROM. The local production of ROM was assessed measuring hydroperoxides in the blood collected from the leg of 30 patients consecutively undergoing LSV stripping and 30 controls. In both the patient group and the control group, the test was repeated 30 days later. We found that ROM levels before surgery are higher in varicose vein patients than in controls ( p <.0001) and that ROM are significantly reduced 30 days after LSV stripping ( p <.0001). At that time point, no significant differences between patients and controls was found. We also found that sex and age do not affect ROM concentration in patients and controls, either before or after surgery. In conclusion, our data indicate that CVI is characterized by significant oxidative stress and that LSV stripping is able to normalize local production of ROM in patients with varicose disease of the lower limbs. We suggest that measurement of ROM might be useful to test the positive effects of LSV stripping in these patients.

  11. A Correlative Study of CD-ROM Picture Books in Classrooms and School Children's Formation of Descriptive Concepts

    ERIC Educational Resources Information Center

    Lu, Chow-Chin; Chen, Yueh-Yun; Chen, Chen-Wei

    2011-01-01

    The central focus of this study was the development, use and evaluation of CD-ROM picture books in elementary school science teaching. Three CD-ROM picture books based on the Campus Insects unit from the new elementary school science curriculum in Taiwan were developed. A quasi-experimental method was used to compare the use of the CD-ROMs and…

  12. CD-ROM-aided Databases

    NASA Astrophysics Data System (ADS)

    Sano, Tomoyuki; Suzuki, Masataka; Nishida, Hideo

    The Development of CAI system using CD-ROM and NAPLPS (North American Presentation Level Protocol Syntax) was taken place by Himeji Dokkyo University. The characteristics of CAI using CD-ROM as information processing series for the department of liberal arts student are described. The system is that the computer program, vast amount of voice data and graphics data are stored in a CD-ROM. It is very effective to improve learning ability of student.

  13. The effects of a human patient simulator vs. a CD-ROM on performance.

    PubMed

    Johnson, Don; Corrigan, Theresa; Gulickson, Gary; Holshouser, Elizabeth; Johnson, Sabine

    2012-10-01

    Military health care personnel need to have skills relative to caring for patients on the battlefield. No studies have compared the two teaching strategies of using the human patient simulator (HPS) and a CD-ROM in caring for combat injuries. The objective of this study was to determine if there were statistically significant differences in HPS and CD-ROM educational strategies relative to caring for patients who have trauma. A pretest/post-test prospective experimental design was used. Anesthesia students were randomly assigned to one of three groups: HPS, CD-ROM, or a control group. A valid and reliable instrument, Combat Performance, was used to evaluate the participant's ability to give care to trauma patients. A repeated analysis of variance and a least significant difference post hoc test were used to analyze the data. The HPS group performed better than the CD-ROM and control groups relative to performance (p = 0.001). There was no difference between the CD-ROM and control group (p = 0.171). We speculate that the HPS group performed better than the CD-ROM group because of the realism. In this study, the HPS method of instruction was a more effective method of teaching than the CD-ROM approach.

  14. Influence of Playing a Prolonged Tennis Match on Shoulder Internal Range of Motion.

    PubMed

    Martin, Caroline; Kulpa, Richard; Ezanno, Felix; Delamarche, Paul; Bideau, Benoit

    2016-08-01

    Shoulder range of motion (ROM) deficits have been identified as an injury risk factor among tennis players. It is well known that shoulder internal rotation deficit increases with age and years of play, but there is a lack of knowledge regarding the influence of a prolonged tennis match on shoulder ROM. To examine changes in shoulder ROM during a prolonged tennis match. Descriptive laboratory study. Shoulder passive internal and external rotation ROM were measured on 8 male tennis players before, every 30 minutes during, and just after a 3-hour tennis match. Total ROM was calculated as the combination of shoulder internal and external rotations. Ball velocity on the serve was measured with a radar gun before, at midmatch, and just after the match. Decreases in shoulder internal rotation (-20.8°; P = .005), total ROM (-24.6°; P = .001), and serve velocity (-1.8 m/s; P = .002) were observed at the end of the match. No statistically significant difference was observed for shoulder external rotation after the match (P = .460). Passive shoulder internal rotation and total ROM are significantly decreased during a 3-hour tennis match. The results show that a prolonged tennis match play can modify values of shoulder ROM. © 2016 The Author(s).

  15. IDC Reengineering Phase 2 & 3 Rough Order of Magnitude (ROM) Cost Estimate Summary (Leveraged NDC Case).

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harris, James M.; Prescott, Ryan; Dawson, Jericah M.

    2014-11-01

    Sandia National Laboratories has prepared a ROM cost estimate for budgetary planning for the IDC Reengineering Phase 2 & 3 effort, based on leveraging a fully funded, Sandia executed NDC Modernization project. This report provides the ROM cost estimate and describes the methodology, assumptions, and cost model details used to create the ROM cost estimate. ROM Cost Estimate Disclaimer Contained herein is a Rough Order of Magnitude (ROM) cost estimate that has been provided to enable initial planning for this proposed project. This ROM cost estimate is submitted to facilitate informal discussions in relation to this project and is NOTmore » intended to commit Sandia National Laboratories (Sandia) or its resources. Furthermore, as a Federally Funded Research and Development Center (FFRDC), Sandia must be compliant with the Anti-Deficiency Act and operate on a full-cost recovery basis. Therefore, while Sandia, in conjunction with the Sponsor, will use best judgment to execute work and to address the highest risks and most important issues in order to effectively manage within cost constraints, this ROM estimate and any subsequent approved cost estimates are on a 'full-cost recovery' basis. Thus, work can neither commence nor continue unless adequate funding has been accepted and certified by DOE.« less

  16. CD-ROM And Knowledge Integration

    NASA Astrophysics Data System (ADS)

    Rann, Leonard S.

    1988-06-01

    As the title of this paper suggests, it is about CD-ROM technology and the structuring of massive databases. Even more, it is about the impact CD-ROM has had on the publication of massive amounts of information, and the unique qualities of the medium that allows for the most sophisticated computer retrieval techniques that have ever been used. I am not drawing on experience as a pedant in the educational field, but rather as a software and database designer who has worked with CD-ROM since its inception. I will be giving examples from my company's current applications, as well as discussing some of the challenges that face information publishers in the future. In particular I have a belief about what the most valuable outlet can be created using CD-ROM will be: The CD-ROM is particularly suited for the mass delivery of information systems and databases that either require or utilize a large amount of computational preprocessing to allow a real-time or interactive response to be achieved. Until the advent of CD-ROM technology this level of sophistication in publication was virtually impossible. I will further explain this later in this paper. First, I will discuss the salient features of CD-ROM that make it unique in the world of data storage for electronic publishing.

  17. Power flow prediction in vibrating systems via model reduction

    NASA Astrophysics Data System (ADS)

    Li, Xianhui

    This dissertation focuses on power flow prediction in vibrating systems. Reduced order models (ROMs) are built based on rational Krylov model reduction which preserve power flow information in the original systems over a specified frequency band. Stiffness and mass matrices of the ROMs are obtained by projecting the original system matrices onto the subspaces spanned by forced responses. A matrix-free algorithm is designed to construct ROMs directly from the power quantities at selected interpolation frequencies. Strategies for parallel implementation of the algorithm via message passing interface are proposed. The quality of ROMs is iteratively refined according to the error estimate based on residual norms. Band capacity is proposed to provide a priori estimate of the sizes of good quality ROMs. Frequency averaging is recast as ensemble averaging and Cauchy distribution is used to simplify the computation. Besides model reduction for deterministic systems, details of constructing ROMs for parametric and nonparametric random systems are also presented. Case studies have been conducted on testbeds from Harwell-Boeing collections. Input and coupling power flow are computed for the original systems and the ROMs. Good agreement is observed in all cases.

  18. CD-ROM and Metering--An Overview.

    ERIC Educational Resources Information Center

    Shear, Victor

    1992-01-01

    Discusses the need for security and metering features for CD-ROM products. Topics covered include user productivity issues, pricing problems, integrated information resources, advantages of CD-ROM distribution systems, unauthorized use, content encryption, and multiple simultaneous meters. (MES)

  19. Submesoscale Flows and Mixing in the Oceanic Surface Layer Using the Regional Oceanic Modeling System (ROMS)

    DTIC Science & Technology

    2014-09-30

    continuation of the evolution of the Regional Oceanic Modeling System (ROMS) as a multi-scale, multi-process model and its utilization for...hydrostatic component of ROMS (Kanarska et al., 2007) is required to increase its efficiency and generality. The non-hydrostatic ROMS involves the solution...instability and wind-driven mixing. For the computational regime where those processes can be partially, but not yet fully resolved, it will

  20. Age and sex differences in ranges of motion and motion patterns.

    PubMed

    Hwang, Jaejin; Jung, Myung-Chul

    2015-01-01

    This study investigated the effects of age and sex on joint ranges of motion (ROMs) and motion patterns. Forty participants performed 18 motions using eight body segments at self-selected speeds. Older subjects showed smaller ROMs than younger subjects for 11 motions; the greatest difference in ROM was 44.9% for eversion/inversion of the foot. Older subjects also required more time than younger subjects to approach the peak angular velocity for six motions. In contrast, sex significantly affected ROMs but not motion patterns. Male subjects exhibited smaller ROMs than female subjects for four motions; the greatest sex-dependent difference in ROM was 29.7% for ulnar/radial deviation of the hand. The age and sex effects depended on the specific segments used and motions performed, possibly because of differences in anatomical structures and frequencies of use of the joints in habitual physical activities between the groups.

  1. Development and Evaluation of a Multimedia CD-ROM for Exercise During Pregnancy and Postpartum

    PubMed Central

    Hausenblas, Heather A.; Brewer, Britton W.; Van Raalte, Judy L.; Cook, Brian; Downs, Danielle Symons; Weis, Carol Ann; Nigg, Claudio; Cruz, Amelia

    2008-01-01

    Objective To meet the need for an interactive product on exercise during pregnancy and postpartum, we developed and evaluated a personally-tailored multimedia CD-ROM. Methods Pregnant and postpartum women, who were randomly assigned to either the experimental group (PregXercise™ CD-ROM) or the control group (CD-ROM with neutral content), navigated through the CD-ROM for 1 hour. Main outcomes were exercise self-efficacy and knowledge. Results In analyses of covariance, compared with the control group, the experimental group had significant increases in self-efficacy and knowledge. Conclusion The multimedia CD-ROM delivering information about exercise motivation, guidelines, and prescription was effective in improving exercise self-efficacy and knowledge. Practice Implications Our preliminary results illustrate that healthcare professionals and researchers may use interactive multimedia for improving exercise behavior and related outcomes with pregnant and postpartum women. PMID:18068940

  2. Minutes of the CD-ROM Workshop

    NASA Technical Reports Server (NTRS)

    King, Joseph H.; Grayzeck, Edwin J.

    1989-01-01

    The workshop described in this document had two goals: (1) to establish guidelines for the CD-ROM as a tool to distribute datasets; and (2) to evaluate current scientific CD-ROM projects as an archive. Workshop attendees were urged to coordinate with European groups to develop CD-ROM, which is already available at low cost in the U.S., as a distribution medium for astronomical datasets. It was noted that NASA has made the CD Publisher at the National Space Science Data Center (NSSDC) available to the scientific community when the Publisher is not needed for NASA work. NSSDC's goal is to provide the Publisher's user with the hardware and software tools needed to design a user's dataset for distribution. This includes producing a master CD and copies. The prerequisite premastering process is described, as well as guidelines for CD-ROM construction. The production of discs was evaluated. CD-ROM projects, guidelines, and problems of the technology were discussed.

  3. Graphene-based nonvolatile terahertz switch with asymmetric electrodes.

    PubMed

    Li, Yan; Yu, Hui; Qiu, Xinyu; Dai, Tingge; Jiang, Jianfei; Wang, Gencheng; Zhang, Qiang; Qin, Yali; Yang, Jianyi; Jiang, Xiaoqing

    2018-01-24

    We propose a nonvolatile terahertz (THz) switch which is able to perform the switching with transient stimulus. The device utilizes graphene as its floating-gate layer, which changes the transmissivity of THz signal by trapping the tunneling charges. The conventional top-down electrode configuration is replaced by a left-right electrode configuration, so THz signals could transmit through this device with the transmissivity being controlled by voltage pulses. The two electrodes are made of metals with different work functions. The resultant asymmetrical energy band structure ensures that both electrical programming and erasing are viable. With the aid of localized surface plasmon resonances in graphene ribbon arrays, the modulation depth is 89% provided that the Femi level of graphene is tuned between 0 and 0.2 eV by proper voltage pulses.

  4. Analog integrated circuits design for processing physiological signals.

    PubMed

    Li, Yan; Poon, Carmen C Y; Zhang, Yuan-Ting

    2010-01-01

    Analog integrated circuits (ICs) designed for processing physiological signals are important building blocks of wearable and implantable medical devices used for health monitoring or restoring lost body functions. Due to the nature of physiological signals and the corresponding application scenarios, the ICs designed for these applications should have low power consumption, low cutoff frequency, and low input-referred noise. In this paper, techniques for designing the analog front-end circuits with these three characteristics will be reviewed, including subthreshold circuits, bulk-driven MOSFETs, floating gate MOSFETs, and log-domain circuits to reduce power consumption; methods for designing fully integrated low cutoff frequency circuits; as well as chopper stabilization (CHS) and other techniques that can be used to achieve a high signal-to-noise performance. Novel applications using these techniques will also be discussed.

  5. Evaluation of COTS SiGe, SOI, and Mixed Signal Electronic Parts for Extreme Temperature Use in NASA Missions

    NASA Technical Reports Server (NTRS)

    Patterson, Richard L.; Hammoud, Ahmad

    2010-01-01

    The NASA Electronic Parts and Packaging (NEPP) Program sponsors a task at the NASA Glenn Research Center titled "Reliability of SiGe, SOI, and Advanced Mixed Signal Devices for Cryogenic Space Missions." In this task COTS parts and flight-like are evaluated by determining their performance under extreme temperatures and thermal cycling. The results from the evaluations are published on the NEPP website and at professional conferences in order to disseminate information to mission planners and system designers. This presentation discusses the task and the 2010 highlights and technical results. Topics include extreme temperature operation of SiGe and SOI devices, all-silicon oscillators, a floating gate voltage reference, a MEMS oscillator, extreme temperature resistors and capacitors, and a high temperature silicon operational amplifier.

  6. Motion deficit in nodal interphalangeal joint osteoarthritis by digital goniometer in housewives.

    PubMed

    Ventura-Ríos, L; Hayes-Salinas, M; Ferrusquia-Toriz, D; Cariño-Escobar, R I; Cruz-Arenas, E; Gutiérrez-Martínez, J; González-Ramírez, L; Hernández-Díaz, C

    2018-06-01

    Range of motion (ROM) measured objectively in nodal hand osteoarthritis (NHOA) is missing. Evaluation of collateral ligaments by ultrasound (US) is unknown in NHOA also. To compare ROM in interphalangeal joints in housewives with nodal OA, with a control group by a digital system using angle to voltage (Multielgon). The second objective was to assess correlation between collateral radial and ulnar ligaments thickness and ROM. For this cross-sectional observational study, we assessed 60 hands with symptomatic NHOA and 30 hands of healthy housewives matched for age. We obtained clinical and demographic characteristics (a complete standardized physical examination of hand joints, DASH questionnaire, pain surveys, gross grasp hand goniometer, and ROM measurements by Multielgon. Presence of synovitis, power Doppler signal, osteophytes, and collateral ligaments thickness was evaluated by US. We used descriptive statistics, Spearman correlation, X 2 test, t test and odds ratio. Significant less gross grasp and ROM in the right hand were observed in NHOA (p = 0.01 for both). Presence of OA, painful joints, disease duration, and score DASH were significant correlated with reduced ROM (OR 4.12, 4.12, 1.04 and 1.09, respectively). Reduced ROM was statistical significant in thumb MCP and IP joints, second and third DIP in dominant hand. There was no association between collateral radial and ulnar ligaments and reduced ROM. Synovitis and osteophytes were more prevalent in OA group. Multielgon demonstrated the pattern of reduced ROM in nodal OA of housewives particularly in MCP and IP thumb joints, second and third distal interphalangeal joints.

  7. Improving in the fasting, but not the postprandial, glucose level is associated with reduction of plasma d-ROMs level in patients with type 2 diabetes.

    PubMed

    Ohara, Makoto; Watanabe, Kentaro; Suzuki, Tatsuya; Sekimizu, Ken-ichi; Motoyama, Masayuki; Ishii, Kazuhito; Sawai, Keisuke; Nakano, Hiroshi; Oba, Kenzo; Mizuno, Kyoichi

    2013-01-01

    This study aimed to evaluate the relationship between improvement of glucose metabolism and plasma levels of diacron-reactive oxygen metabolites (d-ROMs) in patients with type 2 diabetes. As the first daily profile, the plasma levels of glucose and d-ROMs were determined on admission. Then, after treatment to lower plasma glucose levels, the second daily profile of these levels was evaluated. Fasting plasma glucose (FPG), the total area under the curve (AUC) of the daily plasma glucose profile (AUCDP), the AUC of the postprandial plasma glucose levels (AUCPP), the AUC of the daily plasma d-ROMs profile (AUCd-ROMs), the coefficient of variation (CV) of plasma glucose (CVPG), and the mean amplitude of glycemic excursions (MAGE) were calculated. The relationship between the improvement of glucose metabolism and that of oxidative stress in patients with type 2 diabetes was evaluated. The second determinations of FPG, AUCDP, AUCPP, MAGE, and AUCd-ROMs were significantly lower than those of the first determinations, but no significant difference was observed in CVPG. Linear regression analysis demonstrated significant associations between the changes in AUCd-ROMs and the changes in both FPG and AUCDP, whereas no significant association was observed between the change in AUCd-ROMs and the change in AUCPP, CVPG, or MAGE. This study has demonstrated that improvement of the FPG level, but not of the postprandial glucose level, is associated with a reduction of the plasma level of d-ROMs in patients with type 2 diabetes.

  8. CD-ROMs review 1995-1997: a multicentre pilot trial.

    PubMed

    Grey-Lloyd, J

    1998-03-01

    This article describes an evaluation of CD-ROMs carried out at four NHS Trust Libraries in Wales. It covers interactive CD-ROMs which take the form of either computer assisted learning programs, encyclopaedia or well-known text books.

  9. Mechanisms of Shoulder Range of Motion Deficits in Asymptomatic Baseball Players.

    PubMed

    Bailey, Lane B; Shanley, Ellen; Hawkins, Richard; Beattie, Paul F; Fritz, Stacy; Kwartowitz, David; Thigpen, Charles A

    2015-11-01

    Shoulder range of motion (ROM) deficits have been identified as injury risk factors among baseball athletes. Despite the knowledge surrounding these risk factors, there is a lack of consensus regarding the specific tissues responsible for these deficits in ROM. The purpose of this study was to elucidate the primary mechanisms of posterior shoulder tightness (capsular, musculotendinous, bony) by examining the tissue responses that occur with the application of an acute intervention in baseball players with ROM deficits. The hypothesis was that posterior rotator cuff stiffness, not glenohumeral joint mobility, would be primarily responsible for ROM gains observed within an acute treatment setting. Controlled laboratory study. Through use of ultrasound elastography, electromagnetic motion analysis, and ultrasound imaging, posterior rotator cuff stiffness, glenohumeral joint translation, and humeral torsion were examined in 60 asymptomatic baseball players (age, mean ± SD, 19 ± 2 years) with shoulder ROM deficits. Tissue mechanisms were examined concurrently, with the ROM gains elicited by an acute application of instrument-assisted soft tissue mobilization plus self-stretching (n = 30) versus self-stretching only (n = 30). Separate 3-way analyses of variance (group × arm × time) and linear regression analyses were used to determine the treatment effects and relationships between tissue mechanisms and ROM gains. ROM gains were associated with decreases in rotator cuff stiffness (internal rotation: r = 0.35, P = .034; horizontal adduction: r = 0.44, P = .008) and increased humeral retrotorsion (internal rotation: r = -0.35, P = .034), not joint translation (P > .05). Players receiving instrument-assisted soft tissue mobilization plus stretching displayed greater shoulder ROM gains (internal rotation, +5° ± 2° [P = .010]; total arc of motion, +8° ± 6° [P = .010]; horizontal adduction, +7° ± 2° [P = .004]; and decreased posterior rotator cuff stiffness, -0.2 ± 0.3 kPa [P = .050]) compared with players receiving self-stretching alone. Decreases in rotator cuff stiffness were associated with acute ROM gains in baseball players. The study results show that changes in rotator cuff stiffness, not glenohumeral joint mobility or humeral torsion, are most likely associated with the ROM deficits observed in adolescent baseball players. Reducing rotator cuff stiffness may be beneficial in improving the ROM deficits associated with injury risk in overhead athletes. © 2015 The Author(s).

  10. Development and Utilization of Regional Oceanic Modeling System (ROMS). Delicacy, Imprecision, and Uncertainty of Oceanic Simulations: An Investigation with the Regional Oceanic Modeling System (ROMS). Mixing in the Ocean Surface Layer Using the Regional Oceanic Modeling System (ROMS).

    DTIC Science & Technology

    2011-09-30

    community use for ROMS is biogeochemisty: chemical cycles, water quality, blooms , micro-nutrients, larval dispersal, biome transitions, and coupling to...J.C. McWilliams, X. Capet, and J. Kurian, 2010: Heat balance and eddies in the Peru- Chile Current System. Climate Dynamics, 37, in press. doi10.1007

  11. Centralization of symptoms and lumbar range of motion in patients with low back pain.

    PubMed

    Bybee, Ronald F; Olsen, Denise L; Cantu-Boncser, Gloria; Allen, Heather Condie; Byars, Allyn

    2009-05-01

    This quasi-experimental repeated measures study examined the relationship between centralization of symptoms and lumbar flexion and extension range of motion (ROM) in patients with low back pain. Rapid and lasting changes in lumbar ROM have been noted with centralization of symptoms. However, no study has objectively measured the changes in lumbar ROM occurring with centralization. Forty-two adult subjects (mean age, 45.68 years; SD=15.76 years) with low back pain and associated lower extremity symptoms were followed by McKenzie trained physical therapists. Subjects' lumbar ROM was measured at the beginning and end of each patient visit by using double inclinometers, and pain location was documented. Subjects were grouped as 1) centralized, 2) centralizing, or 3) noncentralized for comparisons of symptom and ROM changes. Data were analyzed by using multivariate analysis of variance and one-way analysis of variance. Significance was set at 0.05. A significant difference was found between initial and final mean extension ROM in the centralized and centralizing groups (p=0.003). No significant difference was found in the noncentralized group (p<0.05). Subjects (n=23) who demonstrated a change in pain location during the initial visit also showed a significant (p<0.001) change in extension ROM, whereas patients with no change in pain location (n=19) did not (p=0.848). Lumbar extension ROM increased as centralization occurred.

  12. Self-Myofascial Release: No Improvement of Functional Outcomes in 'Tight' Hamstrings.

    PubMed

    Morton, Robert W; Oikawa, Sara Y; Phillips, Stuart M; Devries, Michaela C; Mitchell, Cameron J

    2016-07-01

    Self-myofascial release (SMR) is a common exercise and therapeutic modality shown to induce acute improvements in joint range of motion (ROM) and recovery; however, no long-term studies have been conducted. Static stretching (SS) is the most common method used to increase joint ROM and decrease muscle stiffness. It was hypothesized that SMR paired with SS (SMR+SS) compared with SS alone over a 4-wk intervention would yield greater improvement in knee-extension ROM and hamstring stiffness. 19 men (22 ± 3 y) with bilateral reduced hamstring ROM had each of their legs randomly assigned to either an SMR+SS or an SS-only group. The intervention consisted of 4 repetitions of SS each for 45 s or the identical amount of SS preceded by 4 repetitions of SMR each for 60 s and was performed on the respective leg twice daily for 4 wk. Passive ROM, hamstring stiffness, rate of torque development (RTD), and maximum voluntary contraction (MVC) were assessed pre- and postintervention. Passive ROM (P < .001), RTD, and MVC (P < .05) all increased after the intervention. Hamstring stiffness toward end-ROM was reduced postintervention (P = .02). There were no differences between the intervention groups for any variable. The addition of SMR to SS did not enhance the efficacy of SS alone. SS increases joint ROM through a combination of decreased muscle stiffness and increased stretch tolerance.

  13. Tomorrow's Online in Today's CD-ROM: Interfaces and Images.

    ERIC Educational Resources Information Center

    Jacso, Peter

    1994-01-01

    Considers the appropriateness of using CD-ROM versus online systems. Topics discussed include cost effectiveness; how current the information is; full-text capabilities; a variety of interfaces; graphical user interfaces on CD-ROM; and possibilities for image representations. (LRW)

  14. A Comparative Survey of Multimedia CD-ROM Encyclopedias.

    ERIC Educational Resources Information Center

    Clements, Jim; Nicholls, Paul

    1995-01-01

    Provides historical background information about multimedia CD-ROM encyclopedias and evaluates 11 recent releases. Discusses access to information, costs, content, technological developments. Rates the text, multimedia, and user interface. A sidebar provides a 10-year chronology of CD-ROM encyclopedias. (AEF)

  15. How to Purchase, Set Up, & Safeguard a CD-ROM Network.

    ERIC Educational Resources Information Center

    Almquist, Arne J.

    1996-01-01

    Presents an overview of the hardware and software required to network CD-ROMs in schools. Topics include network infrastructures, networking software, file server-based systems, CD-ROM servers, vendors of network components, workstations, network utilities, and network management. (LRW)

  16. Longitudinal Changes in Hip Strength and Range of Motion in Female Youth Soccer Players: Implications for ACL Injury, A Pilot Study.

    PubMed

    Nguyen, Anh-Dung; Zuk, Emma F; Baellow, Andrea L; Pfile, Kate R; DiStefano, Lindsay J; Boling, Michelle C

    2017-09-01

    Risk of anterior cruciate ligament (ACL) injuries in young female athletes increases with age, appearing to peak during maturation. Changes in hip muscle strength and range of motion (ROM) during this time may contribute to altered dynamic movement patterns that are known to increase risk of ACL injuries. Understanding the longitudinal changes in hip strength and ROM is needed to develop appropriate interventions to reduce the risk of ACL injuries. To examine the longitudinal changes in hip strength and ROM in female youth soccer players. Longitudinal descriptive study. Field setting. 14 female youth soccer athletes (14.1 ± 1.1 y, 165.8 ± 5.3 cm, 57.5 ± 9.9 kg) volunteered as part of a multiyear risk factor screening project. Clinical measures of hip strength and ROM were collected annually over 3 consecutive years. Passive hip internal rotation (IR), external rotation (ER), abduction (ABD), and adduction (ADD) ROM were measured with a digital inclinometer. Isometric hip ABD and extension (EXT) strength were evaluated using a hand-held dynamometer. Separate repeated-measures ANOVAs compared hip strength and ROM values across 3 consecutive years (P < .05). As youth female soccer players increased in age, there were no changes in normalized hip ABD (P = .830) or EXT strength (P = .062) across 3 consecutive years. Longitudinal changes in hip ROM were observed with increases in hip IR (P = .001) and ABD (P < .001), while hip ADD (P = .009) and ER (P < .001) decreased. Anatomical changes at the hip occur as youth female soccer players increase in age. While there are no changes in hip strength, there is an increase in hip IR and ABD ROM with a concomitant decrease in hip ER and ADD ROM. The resulting asymmetries in hip ROM may decrease the activation and force producing capabilities of the hip muscles during dynamic activities, contributing to altered lower extremity mechanics known to increase the risk of ACL injuries.

  17. Development and evaluation of an interactive CD-ROM for children with leukemia and their families.

    PubMed

    Dragone, Mary Alice; Bush, Patricia J; Jones, Judith K; Bearison, David J; Kamani, Sharmila

    2002-04-01

    To meet the need for an interactive software product to educate children with leukemia, ages 4-11 years, and their families about the disease and its treatment, we developed and evaluated an interactive, comprehensive, multimedia CD-ROM product, Kidz with Leukemia: A Space Adventure. The prototype was tested using a randomized controlled experimental design. Children with leukemia and their parents were randomized to receive either the newly developed CD-ROM or the book You and Leukemia by Lynn Baker. Health care providers (HCPs) and other content/technical experts evaluated only the CD-ROM. Data were collected on children's health locus of control, their understanding of leukemia, and the satisfaction of participants with their assigned intervention. Children in the CD-ROM group, compared with those in the book group, showed increased feelings of control over their health. Although there was a high level of satisfaction with the CD-ROM among all users, younger children and their parents were most satisfied. In conclusion, the CD-ROM, Kidz with Leukemia: A Space Adventure, was found to be a useful, engaging, and empowering tool for children with leukemia and can serve as a model for developing future health-related educational materials.

  18. Criterion validity study of the cervical range of motion (CROM) device for rotational range of motion on healthy adults.

    PubMed

    Tousignant, Michel; Smeesters, Cécil; Breton, Anne-Marie; Breton, Emilie; Corriveau, Hélène

    2006-04-01

    This study compared range of motion (ROM) measurements using a cervical range of motion device (CROM) and an optoelectronic system (OPTOTRAK). To examine the criterion validity of the CROM for the measurement of cervical ROM on healthy adults. Whereas measurements of cervical ROM are recognized as part of the assessment of patients with neck pain, few devices are available in clinical settings. Two papers published previously showed excellent criterion validity for measurements of cervical flexion/extension and lateral flexion using the CROM. Subjects performed neck rotation, flexion/extension, and lateral flexion while sitting on a wooden chair. The ROM values were measured by the CROM as well as the OPTOTRAK. The cervical rotational ROM values using the CROM demonstrated a good to excellent linear relationship with those using the OPTOTRAK: right rotation, r = 0.89 (95% confidence interval, 0.81-0.94), and left rotation, r = 0.94 (95% confidence interval, 0.90-0.97). Similar results were also obtained for flexion/extension and lateral flexion ROM values. The CROM showed excellent criterion validity for measurements of cervical rotation. We propose using ROM values measured by the CROM as outcome measures for patients with neck pain.

  19. Model Order Reduction of Aeroservoelastic Model of Flexible Aircraft

    NASA Technical Reports Server (NTRS)

    Wang, Yi; Song, Hongjun; Pant, Kapil; Brenner, Martin J.; Suh, Peter

    2016-01-01

    This paper presents a holistic model order reduction (MOR) methodology and framework that integrates key technological elements of sequential model reduction, consistent model representation, and model interpolation for constructing high-quality linear parameter-varying (LPV) aeroservoelastic (ASE) reduced order models (ROMs) of flexible aircraft. The sequential MOR encapsulates a suite of reduction techniques, such as truncation and residualization, modal reduction, and balanced realization and truncation to achieve optimal ROMs at grid points across the flight envelope. The consistence in state representation among local ROMs is obtained by the novel method of common subspace reprojection. Model interpolation is then exploited to stitch ROMs at grid points to build a global LPV ASE ROM feasible to arbitrary flight condition. The MOR method is applied to the X-56A MUTT vehicle with flexible wing being tested at NASA/AFRC for flutter suppression and gust load alleviation. Our studies demonstrated that relative to the fullorder model, our X-56A ROM can accurately and reliably capture vehicles dynamics at various flight conditions in the target frequency regime while the number of states in ROM can be reduced by 10X (from 180 to 19), and hence, holds great promise for robust ASE controller synthesis and novel vehicle design.

  20. CMOS array design automation techniques

    NASA Technical Reports Server (NTRS)

    Lombardi, T.; Feller, A.

    1976-01-01

    The design considerations and the circuit development for a 4096-bit CMOS SOS ROM chip, the ATL078 are described. Organization of the ATL078 is 512 words by 8 bits. The ROM was designed to be programmable either at the metal mask level or by a directed laser beam after processing. The development of a 4K CMOS SOS ROM fills a void left by available ROM chip types, and makes the design of a totally major high speed system more realizable.

  1. CD-ROM-aided Databases

    NASA Astrophysics Data System (ADS)

    Miyazaki, Kazuhide; Nishimura, Masayoshi

    Nippon Telegraph & Telephone Corporation (NTT) was the first company in the world to record the entire business classified Tokyo telephone directory containing more than 1,100,000 entries on CD-ROM. NTT's telephone directory on CD-ROM contains the business classification, the names, addresses and telephon numbers of more than 1,100,000 companies located in Tokyo’s 23 wards and surrounding towns. This report about NTT’s telephone directory on CD-ROM was written about the reason of development, outline, and the point at issue.

  2. Design, fabrication, and evaluation of charge-coupled devices with aluminum-anodized-aluminum gates

    NASA Technical Reports Server (NTRS)

    Gassaway, J. D.; Causey, W. H., Jr.

    1977-01-01

    A 4-phase, 49 1/2 bit CCD shift register was designed and fabricated using two levels of aluminum metallization with anodic Al2O3 insulation separating the layers. Test circuitry was also designed and constructed. A numerical analysis of an MOS-RC transmission line was made and results are given to characterize performance for various conductivities. The electrical design of the CCD included a low-noise dual-gate input and a balanced floating diffusion output circuit. Metallization was accomplished both by low voltage DC sputtering and thermal evaporation. The audization was according to published procedures using a buffered tartaric acid bath. Approximately 20 wafers were processed with 50 complete chips per wafer. All devices failed by shorting between the metal levels at some point. Experimental procedures eliminated temperature effects from sintering and drying, anodic oxide thickness, edge effects, photoresist stripping procedures, and metallization techniques as the primary causes of failure. It was believed from a study of SEM images that protuberances (hillocks) grow up from the first level metal through the oxide either causing a direct short or producing a weak, highly stressed insulation point which fails at low voltage. The cause of these hillocks is unknown; however, they have been observed to grow during temperature excursions to 470 C.

  3. Nonvolatile memory thin film transistors using CdSe/ZnS quantum dot-poly(methyl methacrylate) composite layer formed by a two-step spin coating technique

    NASA Astrophysics Data System (ADS)

    Chen, Ying-Chih; Huang, Chun-Yuan; Yu, Hsin-Chieh; Su, Yan-Kuin

    2012-08-01

    The nonvolatile memory thin film transistors (TFTs) using a core/shell CdSe/ZnS quantum dot (QD)-poly(methyl methacrylate) (PMMA) composite layer as the floating gate have been demonstrated, with the device configuration of n+-Si gate/SiO2 insulator/QD-PMMA composite layer/pentacene channel/Au source-drain being proposed. To achieve the QD-PMMA composite layer, a two-step spin coating technique was used to successively deposit QD-PMMA composite and PMMA on the insulator. After the processes, the variation of crystal quality and surface morphology of the subsequent pentacene films characterized by x-ray diffraction spectra and atomic force microscopy was correlated to the two-step spin coating. The crystalline size of pentacene was improved from 147.9 to 165.2 Å, while the degree of structural disorder was decreased from 4.5% to 3.1% after the adoption of this technique. In pentacene-based TFTs, the improvement of the performance was also significant, besides the appearances of strong memory characteristics. The memory behaviors were attributed to the charge storage/discharge effect in QD-PMMA composite layer. Under the programming and erasing operations, programmable memory devices with the memory window (Δ Vth) = 23 V and long retention time were obtained.

  4. The Application of a Modified d-ROMs Test for Measurement of Oxidative Stress and Oxidized High-Density Lipoprotein

    PubMed Central

    Ito, Fumiaki; Ito, Tomoyuki; Suzuki, Chinatsu; Yahata, Tomoyo; Ikeda, Kazuyuki; Hamaoka, Kenji

    2017-01-01

    Reactive oxygen species (ROS) are involved in the initiation and progression of atherosclerosis. ROS-derived hydroperoxides, as an indicator of ROS production, have been measured by using the diacron reactive oxygen metabolites (d-ROMs) test, which requires iron-containing transferrin in the reaction mixture. In this study we developed a modified d-ROMs test, termed the Fe-ROMs test, where iron ions were exogenously added to the reaction mixture. This modification is expected to exclude the assay variation that comes from different blood iron levels in individuals. In addition, this Fe-ROMs test was helpful for determining the class of plasma lipoproteins that are hydroperoxidized. Low-density lipoprotein/very low-density lipoprotein (LDL/VLDL) and high-density lipoprotein (HDL) were purified by use of an LDL/VLDL purification kit and the dextran sulfate-Mg2+ precipitation method, respectively; their hydroperoxide contents were assessed by performing the Fe-ROMs test. The majority of the hydroperoxides were detected only in the HDL fraction, not in the LDL/VLDL. Further detailed analysis of HDLs by size-exclusion high-performance liquid chromatography revealed that the hydroperoxide-containing molecules were small-sized HDLs. Because HDL was shown to be the principal vehicle for the plasma hydroperoxides, this Fe-ROMs test is a beneficial method for the assessment of oxidized-HDL levels. Indeed, Fe-ROMs levels were strongly associated with the levels of oxidized HDL, which were determined by performing the malondialdehyde-modified HDL enzyme immunoassay. In conclusion, the Fe-ROMs test using plasma itself or the HDL fraction after dextran sulfate-Mg2+ precipitation is useful to assess the functionality of HDL, because the oxidation of HDL impairs its antiatherogenic capacity. PMID:28230785

  5. Analysis of reactive oxygen metabolites (ROMs) after cardiovascular surgery as a marker of oxidative stress.

    PubMed

    Kanaoka, Yuji; Inagaki, Ei-ichirou; Hamanaka, Souhei; Masaki, Hisao; Tanemoto, Kazuo

    2010-10-01

    The transient systemic low perfusion that occurs during cardiovascular surgery leads to oxidative stress and the production of free radicals. A systemic increase of various markers of oxidative stress has been shown to occur during cardiopulmonary bypass (CPB). However, these markers have not been adequately evaluated because they seem to be reactive and short-lived. Here, oxidative stress was measured using the free radical analytical system (FRAS 4) assessing the derivatives of reactive oxygen metabolites (d-ROMs) and biological antioxidant potential (BAP). Blood samples were taken from 21 patients undergoing elective cardiovascular surgery. CPB was used in 15 patients, and abdominal aortic aneurysm (AAA) surgery without CPB was performed in 6. Measurements of d-ROMs and BAP were taken before surgery, 1 day, 1 week, and 2 weeks after surgery, and oxidative stress was evaluated. The d-ROM level increased gradually after cardiovascular surgery up to 2 weeks. Over time, the d-ROM level after surgery involving CPB became higher than that after AAA surgery. This difference reached statistical significance at 1 week and lasted to 2 weeks. The prolongation of CPB was prone to elevate the d-ROM level whereas the duration of the aortic clamp in AAA surgery had no relation to the d-ROM level. The BAP was also elevated after surgery, and was positively correlated with the level of d-ROMs. In this study, patients who underwent cardiovascular surgery involving CPB had significant oxidative damage. The production of ROMs was shown to depend on the duration of CPB. Damage can be reduced if CPB is avoided. When CPB must be used, shortening the CPB time may be effective in reducing oxidative stress.

  6. The Application of a Modified d-ROMs Test for Measurement of Oxidative Stress and Oxidized High-Density Lipoprotein.

    PubMed

    Ito, Fumiaki; Ito, Tomoyuki; Suzuki, Chinatsu; Yahata, Tomoyo; Ikeda, Kazuyuki; Hamaoka, Kenji

    2017-02-21

    Reactive oxygen species (ROS) are involved in the initiation and progression of atherosclerosis. ROS-derived hydroperoxides, as an indicator of ROS production, have been measured by using the diacron reactive oxygen metabolites (d-ROMs) test, which requires iron-containing transferrin in the reaction mixture. In this study we developed a modified d-ROMs test, termed the Fe-ROMs test, where iron ions were exogenously added to the reaction mixture. This modification is expected to exclude the assay variation that comes from different blood iron levels in individuals. In addition, this Fe-ROMs test was helpful for determining the class of plasma lipoproteins that are hydroperoxidized. Low-density lipoprotein/very low-density lipoprotein (LDL/VLDL) and high-density lipoprotein (HDL) were purified by use of an LDL/VLDL purification kit and the dextran sulfate-Mg 2+ precipitation method, respectively; their hydroperoxide contents were assessed by performing the Fe-ROMs test. The majority of the hydroperoxides were detected only in the HDL fraction, not in the LDL/VLDL. Further detailed analysis of HDLs by size-exclusion high-performance liquid chromatography revealed that the hydroperoxide-containing molecules were small-sized HDLs. Because HDL was shown to be the principal vehicle for the plasma hydroperoxides, this Fe-ROMs test is a beneficial method for the assessment of oxidized-HDL levels. Indeed, Fe-ROMs levels were strongly associated with the levels of oxidized HDL, which were determined by performing the malondialdehyde-modified HDL enzyme immunoassay. In conclusion, the Fe-ROMs test using plasma itself or the HDL fraction after dextran sulfate-Mg 2+ precipitation is useful to assess the functionality of HDL, because the oxidation of HDL impairs its antiatherogenic capacity.

  7. CD-ROM: towards a strategy for teaching and learning.

    PubMed

    Aarvold, J; Walton, G

    1992-12-01

    Compact Disc Read Only Memory (CD-ROM) represents an exciting innovation in nurse education yet paradoxically has a potential to induce disillusionment and frustration. Purchasers of systems may well find that their investment does not bring the benefits they had been lead to expect. CD-ROM systems have the capacity to generate huge quantities of data on an equally large number of nursing topics. Arguably this very capability ensures certain 'built-in' problems. The purpose of this articles is to provide nurse teachers with information about CD-ROM, to highlight the resource implications of CD-ROM use and to consider the relative merits of various teaching and learning methods. To be worthwhile, strategies developed must be part of an information retrieval skills programme.

  8. Relationship between ankle range of motion and Biodex Balance System in females and males.

    PubMed

    Sung, Eun-Sook; Kim, Jung-Hyun

    2018-02-01

    This study examined whether there are differences between range of motion (ROM) and balance in lower extremities according to gender. A total of 31 male and 28 female students measured plantar flexion (PF), dorsiflexion, inversion (IV), eversion (EV), hip flexion (HF), hip internal rotation (HIR), and hip external rotation (HER) and tested on the Biodex Balance System. ROM of PF and HF were significantly high the female group and ROMs of IV, EV, HIR, and HER were significantly higher the male group than in the female group. Low ROM of PF may be more negative related to overall balance, especially, back balance in males; therefore, it is necessary to assess and plan the training program for PF ROM in male students.

  9. Design and implementation of an optical Gaussian noise generator

    NASA Astrophysics Data System (ADS)

    Za~O, Leonardo; Loss, Gustavo; Coelho, Rosângela

    2009-08-01

    A design of a fast and accurate optical Gaussian noise generator is proposed and demonstrated. The noise sample generation is based on the Box-Muller algorithm. The functions implementation was performed on a high-speed Altera Stratix EP1S25 field-programmable gate array (FPGA) development kit. It enabled the generation of 150 million 16-bit noise samples per second. The Gaussian noise generator required only 7.4% of the FPGA logic elements, 1.2% of the RAM memory, 0.04% of the ROM memory, and a laser source. The optical pulses were generated by a laser source externally modulated by the data bit samples using the frequency-shift keying technique. The accuracy of the noise samples was evaluated for different sequences size and confidence intervals. The noise sample pattern was validated by the Bhattacharyya distance (Bd) and the autocorrelation function. The results showed that the proposed design of the optical Gaussian noise generator is very promising to evaluate the performance of optical communications channels with very low bit-error-rate values.

  10. Networking CD-ROMs: A Tutorial Introduction.

    ERIC Educational Resources Information Center

    Perone, Karen

    1996-01-01

    Provides an introduction to CD-ROM networking. Highlights include LAN (local area network) architectures for CD-ROM networks, peer-to-peer networks, shared file and dedicated file servers, commercial software/vendor solutions, problems, multiple hardware platforms, and multimedia. Six figures illustrate network architectures and a sidebar contains…

  11. CD-ROM: Potential and Pitfalls.

    ERIC Educational Resources Information Center

    Dreiss, L. Jack; Bashir, Shahzad

    1990-01-01

    Examines issues surrounding CD-ROM as an organizational information management tool: (1) the CD-ROM market; (2) pitfalls, including compatibility, effect on existing information systems, fear of obsolescence, protection of sensitive information, and lack of successful role models; and (3) factors that will fuel growth, including greater…

  12. Adding-point strategy for reduced-order hypersonic aerothermodynamics modeling based on fuzzy clustering

    NASA Astrophysics Data System (ADS)

    Chen, Xin; Liu, Li; Zhou, Sida; Yue, Zhenjiang

    2016-09-01

    Reduced order models(ROMs) based on the snapshots on the CFD high-fidelity simulations have been paid great attention recently due to their capability of capturing the features of the complex geometries and flow configurations. To improve the efficiency and precision of the ROMs, it is indispensable to add extra sampling points to the initial snapshots, since the number of sampling points to achieve an adequately accurate ROM is generally unknown in prior, but a large number of initial sampling points reduces the parsimony of the ROMs. A fuzzy-clustering-based adding-point strategy is proposed and the fuzzy clustering acts an indicator of the region in which the precision of ROMs is relatively low. The proposed method is applied to construct the ROMs for the benchmark mathematical examples and a numerical example of hypersonic aerothermodynamics prediction for a typical control surface. The proposed method can achieve a 34.5% improvement on the efficiency than the estimated mean squared error prediction algorithm and shows same-level prediction accuracy.

  13. NASA space and Earth science data on CD-ROM

    NASA Technical Reports Server (NTRS)

    Towheed, Syed S.

    1993-01-01

    The National Space Science Data Center (NSSDC) is very interested in facilitating the widest possible use of the scientific data acquired through NASA spaceflight missions. Therefore, NSSDC has participated with projects and data management elements throughout the NASA science environment in the creation, archiving, and dissemination of data using Compact Disk-Read Only Memory (CD-ROM). This CD-ROM technology has the potential to enable the dissemination of very large data volumes at very low prices to a great many researchers, students and their teachers, and others. This catalog identifies and describes the scientific CD-ROM's now available from NSSDC including the following data sets: Einstein Observatory CD-ROM, Galileo Cruise Imaging on CD-ROM, International Halley Watch, IRAS Sky Survey Atlas, Infrared Thermal Mapper (IRTM), Magellan (MIDR), Magellan (ARCDR's), Magellan (GxDR's), Mars Digital Image Map (MDIM), Outer Planets Fields & Particles Data, Pre-Magellan, Selected Astronomical Catalogs, TOMS Gridded Ozone Data, TOMS Ozone Image Data, TOMS Update, Viking Orbiter Images of Mars, and Voyager Image.

  14. Evaluation of two CD-ROMs from a series on cell biology.

    PubMed

    Sander, Uwe; Kerlen, Gertraude; Steinke, Mattias; Huk, Thomas; Floto, Christian

    2003-01-01

    Two CD-ROMs from a series dealing with various major aspects of cell biology are evaluated in this paper using quantitative and qualitative approaches. The findings delimit similarities and differences of the two CD-ROMs and shed light on how the programs could be used in the learning process and how they should not be. The overall impression, as well as the graphical and technical features, received a predominantly good rating. The defined target groups were reached (e.g., students in secondary schools), different learning approaches were supported (e.g., discovery and autonomous learning), the CD-ROMs' usability was assessed as being easy and intuitive, and the majority of the evaluators were satisfied with the level of interactivity. Navigational problems encountered in CD-ROM 1 were overcome by a successful implementation of new navigational functions in CD-ROM 2. Most students found the CD-ROM to be a suitable complement to, or an extension of, their lessons. We conclude that many, but not all of the requirements for the various stages of the learning process could be satisfied with the existing CD-ROMs. The requirements not met are discussed to obtain insights that could help to improve the production of multimedia learning material. The use of quantitative and qualitative approaches in the evaluation of learning modules is discussed, as the study began by collecting and analyzing anecdotal reviews and was then extended to include a qualitative evaluation.

  15. White Blood Cells, Neutrophils, and Reactive Oxygen Metabolites among Asymptomatic Subjects.

    PubMed

    Kotani, Kazuhiko; Sakane, Naoki

    2012-06-01

    Chronic inflammation and oxidative stress are associated with health and the disease status. The objective of the present study was to investigate the association among white blood cell (WBC) counts, neutrophil counts as a WBC subpopulation, and diacron reactive oxygen metabolites (d-ROMs) levels in an asymptomatic population. The clinical data, including general cardiovascular risk variables and high-sensitivity C-reactive protein (hs-CRP), were collected from 100 female subjects (mean age, 62 years) in outpatient clinics. The correlation of the d-ROMs with hs-CRP, WBC, and neutrophil counts was examined. The mean/median levels were WBC counts 5.9 × 10(9)/L, neutrophil counts 3.6 × 10(9)/L, hs-CRP 0.06 mg/dL, and d-ROMs 359 CURR U. A simple correlation analysis showed a significant positive correlation of the d-ROMs with the WBC counts, neutrophil counts, or hs-CRP levels. The correlation between d-ROMs and neutrophil counts (β = 0.22, P < 0.05), as well as that between d-ROMs and hs-CRP (β = 0.28, P < 0.01), remained significant and independent in a multiple linear regression analysis adjusted for other variables. A multiple linear regression analysis showed that WBC counts had only a positive correlation tendency to the d-ROMs. Neutrophils may be slightly but more involved in the oxidative stress status, as assessed by d-ROMs, in comparison to the overall WBC. Further studies are needed to clarify the biologic mechanism(s) of the observed relationship.

  16. Oxidative stress in obesity and metabolic syndrome in children and adolescents.

    PubMed

    Faienza, Maria Felicia; Francavilla, Ruggiero; Goffredo, Rocco; Ventura, Annamaria; Marzano, Flaviana; Panzarino, Gianvito; Marinelli, Grazia; Cavallo, Luciano; Di Bitonto, Giovanna

    2012-01-01

    The aim of this study was to investigate the alterations in the oxidant/antioxidant status in obese children with and without metabolic syndrome (MetS). We recruited 25 Caucasian obese children with MetS, 30 Caucasian children with simple obesity and a control group of 30 Caucasian children. We performed diacron-reactive oxygen metabolites (d-ROMs) test and biological antioxidant potential (BAP) test in order to evaluate the oxidant-antioxidant status in recruited patients. d-ROM level was significantly higher in obese children with and without MetS (p = 0.005). The total antioxidant capacity (BAP level) was reduced in MetS and noMetS children compared to controls (p = 0.009). The subjects without MetS had higher d-ROMs test and lower BAP/d-ROMs ratio than subjects with MetS (although not significant). The ratio BAP/d-ROMs was higher in controls than noMetS and MetS children (p < 0.0001). d-ROM level was higher in prepubertal subjects with MetS than pubertal ones (p = 0.03). A direct correlation was found between d-ROM levels and BMI SDS (p = 0.0005), while an inverse correlation was found between BAP and BMI SDS (p = 0.004) and BAP/d-ROMs and BMI SDS (p = 0.0001). This result confirms that fat accumulation plays a key role in the pathogenesis of systemic oxidative stress already during pediatric age. Copyright © 2012 S. Karger AG, Basel.

  17. Evaluation of Two CD-ROMs from a Series on Cell Biology

    PubMed Central

    Sander, Uwe; Kerlen, Gertraude; Steinke, Mattias; Huk, Thomas; Floto, Christian

    2003-01-01

    Two CD-ROMs from a series dealing with various major aspects of cell biology are evaluated in this paper using quantitative and qualitative approaches. The findings delimit similarities and differences of the two CD-ROMs and shed light on how the programs could be used in the learning process and how they should not be. The overall impression, as well as the graphical and technical features, received a predominantly good rating. The defined target groups were reached (e.g., students in secondary schools), different learning approaches were supported (e.g., discovery and autonomous learning), the CD-ROMs' usability was assessed as being easy and intuitive, and the majority of the evaluators were satisfied with the level of interactivity. Navigational problems encountered in CD-ROM 1 were overcome by a successful implementation of new navigational functions in CD-ROM 2. Most students found the CD-ROM to be a suitable complement to, or an extension of, their lessons. We conclude that many, but not all of the requirements for the various stages of the learning process could be satisfied with the existing CD-ROMs. The requirements not met are discussed to obtain insights that could help to improve the production of multimedia learning material. The use of quantitative and qualitative approaches in the evaluation of learning modules is discussed, as the study began by collecting and analyzing anecdotal reviews and was then extended to include a qualitative evaluation. PMID:14673491

  18. Pain sensitivity and torque used during measurement predicts change in range of motion at the knee.

    PubMed

    Bishop, Mark D; George, Steven Z

    2017-01-01

    To determine the extent to which changes in knee range of motion (ROM) after a stretching program are related to sensory factors at the time of testing and the amount of force used during the measurement of ROM, rather than changes in soft-tissue properties. Randomized, single-blind design. Participants were randomly assigned to a control or stretching group. Research laboratory. Forty-four healthy volunteers (22.8±2.8 years of age; 23 men). The stretching group undertook static stretching twice a day for 8 weeks. The control group continued with routine activity, but was discouraged from starting a flexibility program. ROM and tissue extensibility was assessed using a Biodex3 dynamometer, and ratings of thermal pain were collected at baseline and at 4 and 8 weeks by an examiner blinded to group assignment. Multilevel modeling was used to examine predictors of ROM across time. The stretching group showed a 6% increase, and the control group had a 2% increase, in ROM over the 8-week program. However, when fixed and random effects were tested in a complete model, the group assignment was not significant. End-point torque during ROM testing ( p =0.021) and the ratings in response to thermal testing ( p <0.001) were significant, however. ROM measured in a testing session was not predicted by assignment to a stretching program. Rather, ROM was predicted by the ratings of thermal stimuli and the peak torque used to apply the stretch.

  19. Exploring CD-ROM Encyclopedias.

    ERIC Educational Resources Information Center

    Urrows, Henry; Urrows, Elizabeth

    1989-01-01

    Review of encyclopedias and other databases available on CD-ROM focuses on the International Encyclopedia of Education (IEE). Problems with software and hardware are described, perspectives from the computer industry are presented, the commercial potential of CD-ROMs is discussed, and a list of sources is provided. (six references) (LRW)

  20. Choosing a CD-ROM Encyclopedia: How to Critically Evaluate the Product.

    ERIC Educational Resources Information Center

    Dickinson, Gail

    1990-01-01

    Offers criteria for the critical evaluation of CD-ROM encyclopedias. Differences between CD-ROM and print encyclopedias are discussed; search strategies are explained; evaluation criteria are suggested, including help messages, screen format, indexing method, and graphics and print options; future considerations are suggested, including…

  1. CD-ROMs Proliferate--Part 2: Business/Science/Government CD-ROM Disks.

    ERIC Educational Resources Information Center

    Desmarais, Norman

    1989-01-01

    This second of a two-part article on CD-ROM products highlights applications relating to business, medicine, law, government, education, science, geography, linguistics, aviation, florists, and newsreel summaries. The names and addresses of 45 vendors connected with the optical publishing industry are listed. (LRW)

  2. Feasibility study, software design, layout and simulation of a two-dimensional fast Fourier transform machine for use in optical array interferometry

    NASA Technical Reports Server (NTRS)

    Boriakoff, Valentin; Chen, Wei

    1990-01-01

    The NASA-Cornell Univ.-Worcester Polytechnic Institute Fast Fourier Transform (FFT) chip based on the architecture of the systolic FFT computation as presented by Boriakoff is implemented into an operating device design. The kernel of the system, a systolic inner product floating point processor, was designed to be assembled into a systolic network that would take incoming data streams in pipeline fashion and provide an FFT output at the same rate, word by word. It was thoroughly simulated for proper operation, and it has passed a comprehensive set of tests showing no operational errors. The black box specifications of the chip, which conform to the initial requirements of the design as specified by NASA, are given. The five subcells are described and their high level function description, logic diagrams, and simulation results are presented. Some modification of the Read Only Memory (ROM) design were made, since some errors were found in it. Because a four stage pipeline structure was used, simulating such a structure is more difficult than an ordinary structure. Simulation methods are discussed. Chip signal protocols and chip pinout are explained.

  3. Story Games: Marrying Silicon, Celluloid, and CD-ROM.

    ERIC Educational Resources Information Center

    Gussin, Lawrence

    1994-01-01

    Reports on themes emphasized at the April 1994 Computer Game Developers Conference held in Santa Clara (California), including the exploding CD-ROM marketplace and the potential and challenge of using CD-ROM's multimedia capacity to build cinema-quality stories and characters into computer games. Strategies for introducing more complex plots are…

  4. NASA educational CD-ROMs: research and evaluation

    NASA Technical Reports Server (NTRS)

    Knudsen, R.

    2002-01-01

    Since the introduction of educational technology in the K-12 classroom, educators have been flooded with a seemingly endless flow of educational CD-ROMs. NASA has contributed to this new trend in educational technology by developing a wide range of some of the lastest, most high-tech CD-ROMs in the industry.

  5. CD-ROM: A New Light for the Blind and Visually Impaired.

    ERIC Educational Resources Information Center

    Mates, Barbara T.

    1990-01-01

    Describes ways of using CD-ROM technology for the benefit of blind and visually impaired library patrons. Science, reference, and American historical documents that can be converted to braille, large print, or voice output from CD-ROMs are described, and hardware, software, and staff considerations are discussed. (LRW)

  6. Are CD-ROM LANs a Thing of the Past?

    ERIC Educational Resources Information Center

    Mehta, Apurva

    1996-01-01

    Remote access to full-text and CD-ROM databases using the Internet has advantages over a CD-ROM local area network. Topics include speed, document delivery, multiple platforms, technical support, licensing, copyright, and access to graphics. Considerations of duplication of information, platform compatibility, print versus digital media, back…

  7. CD-ROM Integration Peaks Student Interest in Inquiry.

    ERIC Educational Resources Information Center

    O'Bannon, Blanche

    1997-01-01

    Discussion of learning processes examines past educational practices and considers how CD-ROM technology can impact teaching and learning. A lesson plan for elementary school science that uses a CD-ROM encyclopedia is presented that includes instructional goals, performance objectives, teaching and learning activities, and assessment methods.…

  8. Scaffolding or Distracting: CD-ROM Storybooks and Young Readers

    ERIC Educational Resources Information Center

    Pearman, Cathy J.; Chang, Ching-Wen

    2010-01-01

    CD-ROM storybooks, often referred to as electronic texts, e-books, and interactive stories, are learning tools with supplemental features such as automatic reading of text, sound effects, word pronunciations, and graphic animations which support the development of reading skills and comprehension in beginning readers. Some CD-ROM storybooks also…

  9. Annelids. A Multimedia CD-ROM. [CD-ROM].

    ERIC Educational Resources Information Center

    2001

    This CD-ROM is designed for classroom and individual use to teach and learn about annelids. Integrated animations, custom graphics, three-dimensional representations, photographs, and sound are featured for use in user-controlled activities. Interactive lessons are available to reinforce the subject material. Pre- and post-testing sections are…

  10. My Favorite Things Electronically Speaking, 1997 Edition.

    ERIC Educational Resources Information Center

    Glantz, Shelley

    1997-01-01

    Responding to an informal survey, 96 media specialists named favorite software, CD-ROMs, and online sites. This article lists automation packages, electronic encyclopedias, CD-ROMs, electronic magazine indexes, CD-ROM and online database services, electronic sources of current events, laser disks for grades 6-12, word processing programs for…

  11. REGIONAL OXIDANT MODEL (ROM) USER'S GUIDE, PART 1: THE ROM PREPROCESSORS

    EPA Science Inventory

    The Regional Oxidant Model (ROM) determines hourly concentrations and fates of zone and 34 other chemical species over a scale of 1000 km x 1000 km for ozone "episodes" of up to one month's duration. he model structure, based on phenomenological concepts, consists of 3 1/2 layers...

  12. 21 CFR 1.235 - How and when do you cancel your facility's registration information?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... and faxed cancellations into its registration system, along with CD-ROM cancellations, as soon as... a confirmation. (e) Cancellation by CD-ROM for multiple submissions. If, for example, you do not... cancel your facilities' registrations using a CD-ROM. (1) Registrants submitting their cancellations in...

  13. 21 CFR 1.235 - How and when do you cancel your facility's registration information?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... and faxed cancellations into its registration system, along with CD-ROM cancellations, as soon as... a confirmation. (e) Cancellation by CD-ROM for multiple submissions. If, for example, you do not... cancel your facilities' registrations using a CD-ROM. (1) Registrants submitting their cancellations in...

  14. 21 CFR 1.235 - How and when do you cancel your facility's registration information?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... and faxed cancellations into its registration system, along with CD-ROM cancellations, as soon as... a confirmation. (e) Cancellation by CD-ROM for multiple submissions. If, for example, you do not... cancel your facilities' registrations using a CD-ROM. (1) Registrants submitting their cancellations in...

  15. 21 CFR 1.235 - How and when do you cancel your facility's registration information?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... and faxed cancellations into its registration system, along with CD-ROM cancellations, as soon as... a confirmation. (e) Cancellation by CD-ROM for multiple submissions. If, for example, you do not... cancel your facilities' registrations using a CD-ROM. (1) Registrants submitting their cancellations in...

  16. Effectiveness of a Lab Manual Delivered on CD-ROM

    ERIC Educational Resources Information Center

    Brickman, Peggy; Ketter, Catherine A. Teare; Pereira, Monica

    2005-01-01

    Although electronic instructional media are becoming increasingly prevalent in science classrooms, their worth remains unproven. Here, student perceptions and performance using CD-ROM delivery of lab materials are assessed. Numerous learning barriers that produced lower lab grades for students using a CD-ROM lab manual in comparison to a print…

  17. Publication Of Oceanographic Data on CD-ROM

    NASA Technical Reports Server (NTRS)

    Hilland, Jeffrey E.; Smith, Elizabeth A.; Martin, Michael D.

    1992-01-01

    Large collections of oceanographic data and other large collections of data published on CD-ROM's in formats facilitating access and analysis. Involves four major steps: preprocessing, premastering, mastering, and verification. Large capacity, small size, commercial availability, long-life, and standard format of CD-ROM's offer advantages over computer-compatible magnetic tape.

  18. Multisensory Public Access Catalogs on CD-ROM.

    ERIC Educational Resources Information Center

    Harrison, Nancy; Murphy, Brower

    1987-01-01

    BiblioFile Intelligent Catalog is a CD-ROM-based public access catalog system which incorporates graphics and sound to provide a multisensory interface and artificial intelligence techniques to increase search precision. The system can be updated frequently and inexpensively by linking hard disk drives to CD-ROM optical drives. (MES)

  19. CD-ROM and Libraries.

    ERIC Educational Resources Information Center

    Murphy, Brower

    1985-01-01

    The Compact Disc-Read Only Memory (CD-ROM) data format is explained and illustrated, noting current and potential applications. The "5-inch" compact laserdisc is described and photographs of an IBM PC/Hitachi CD-ROM system adopted by Library Corporation to support its MARC database--BiblioFile--are presented. Screen displays for…

  20. CD-ROM versus Online.

    ERIC Educational Resources Information Center

    Wiedemer, John David; Boelio, David B.

    1995-01-01

    Compares compact discs (CD-ROMs) and online services in terms of cost of information delivery; system advantages and disadvantages; future possibilities; and role in the National Information Infrastructure. Analysis reveals that CD-ROMs have the lowest information delivery cost and are endorsed by the marketplace as a cost-effective way to deliver…

  1. An Experimental Test of CD-ROM Aided Instruction in Transnational Management.

    ERIC Educational Resources Information Center

    Oviatt, Benjamin M.; Bansal, Ptraima; Houghton, Susan

    2000-01-01

    Twenty-seven graduate students used a CD-ROM program to study transnational management, while a control group (n=26) used traditional study methods. Use of the CD-ROM was not associated with better examination performance. Implications for increased investment in new classroom technology are drawn. (Author/DB)

  2. Serials Information on CD-ROM: A Reference Perspective.

    ERIC Educational Resources Information Center

    Karch, Linda S.

    1990-01-01

    Describes Ulrich's PLUS (a CD-ROM version of Ulrich's serials directories) and EBSCO's CD-ROM version of "The Serials Directory," and compares the two in terms of their use as reference tools. Areas discussed include database content, user aids, system features, search features, and a comparison of search results. Equipment requirements…

  3. Enhancing Your CD-ROM Services with Signage Systems.

    ERIC Educational Resources Information Center

    Ekhaml, Leticia

    1994-01-01

    Describes how to use effective signage, or visual guidance, for more efficient use of CD-ROM technology in elementary and secondary school library media centers. Setting CD-ROM policies and procedures is considered; the use of posters, brochures, flowcharts, and other formats is discussed; and examples are included. (LRW)

  4. Galerkin Method for Nonlinear Dynamics

    NASA Astrophysics Data System (ADS)

    Noack, Bernd R.; Schlegel, Michael; Morzynski, Marek; Tadmor, Gilead

    A Galerkin method is presented for control-oriented reduced-order models (ROM). This method generalizes linear approaches elaborated by M. Morzyński et al. for the nonlinear Navier-Stokes equation. These ROM are used as plants for control design in the chapters by G. Tadmor et al., S. Siegel, and R. King in this volume. Focus is placed on empirical ROM which compress flow data in the proper orthogonal decomposition (POD). The chapter shall provide a complete description for construction of straight-forward ROM as well as the physical understanding and teste

  5. CD-ROM-aided Databases

    NASA Astrophysics Data System (ADS)

    Masuyama, Keiichi

    CD-ROM has rapidly evolved as a new information medium with large capacity, In the U.S. it is predicted that it will become two hundred billion yen market in three years, and thus CD-ROM is strategic target of database industry. Here in Japan the movement toward its commercialization has been active since this year. Shall CD-ROM bussiness ever conquer information market as an on-disk database or electronic publication? Referring to some cases of the applications in the U.S. the author views marketability and the future trend of this new optical disk medium.

  6. The Relation Between Stretching Typology and Stretching Duration: The Effects on Range of Motion.

    PubMed

    Thomas, Ewan; Bianco, Antonino; Paoli, Antonio; Palma, Antonio

    2018-04-01

    Different stretching strategies and protocols are widely used to improve flexibility or maintain health, acting on the muscle tendon-unit, in order to improve the range of motion (ROM) of the joints. This review aims to evaluate the current body of literature in order to understand the relation between stretching typology and ROM, and secondly to evaluate if a relation exists between stretching volume (either as a single training session, weekly training and weekly frequency) and ROM, after long-term stretching. Twenty-three articles were considered eligible and included in the quantitative synthesis. All stretching typologies showed ROM improvements over a long-term period, however the static protocols showed significant gains (p<0.05) when compared to the ballistic or PNF protocols. Time spent stretching per week seems fundamental to elicit range of movement improvements when stretches are applied for at least or more than 5 min, whereas the time spent stretching within a single session does not seem to have significant effects for ROM gains. Weekly frequency is positively associated to ROM. Evaluated data indicates that performing stretching at least 5 days a week for at least 5 min per week using static stretching may be beneficial to promote ROM improvements. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Reactive oxygen metabolites (ROMs) as an index of oxidative stress in obstructive sleep apnea patients.

    PubMed

    Christou, Kostas; Markoulis, Nikolaos; Moulas, Anargyros N; Pastaka, Chaido; Gourgoulianis, Kostantinos I

    2003-09-01

    Obstructive sleep apnea syndrome (OSA) is accompanied by oxygen desaturation and arousal from sleep. Free oxygen radicals are highly reactive molecules which could be produced by the OSA phenomenon of hypoxia/reoxygenation: cyclical alterations of arterial oxygen saturation with oxygen desaturation developing in response to apneas followed by resumption of oxygen saturation during hyperventilation. On the basis of these considerations, it was hypothesized that OSA may be linked to increased oxidative stress. Twenty-six participants gave an interview during which a physician asked them about their age, smoking habits, and symptoms such as excessive daytime sleepiness and snoring. Physical examination and polysomnography were performed during their hospitalization. Reactive oxygen metabolites (ROMs) were measured in blood samples by the diacron reactive oxygen metabolites (D-ROM) test. Twenty-one out of 26 subjects had an apnea/hypopnea index greater than 5 (OSA group). The measurement of free radicals was high in OSA patients. Furthermore, ROMs values in OSA patients were linearly correlated with the apnea/hypopnea index (R = 0.426; p = 0.042). The predictive value of a positive D-ROM test is 81%. ROMs were elevated in patients with OSA. When OSA was severe, similarly the value of ROMs in blood samples was enhanced, and the probable underlying mechanism for these events is the hypoxia/reoxygenation phenomenon.

  8. Influence of restricted vision and knee joint range of motion on gait properties during level walking and stair ascent and descent.

    PubMed

    Demura, Tomohiro; Demura, Shin-ich

    2011-01-01

    Because elderly individuals experience marked declines in various physical functions (e.g., vision, joint function) simultaneously, it is difficult to clarify the individual effects of these functional declines on walking. However, by imposing vision and joint function restrictions on young men, the effects of these functional declines on walking can be clarified. The authors aimed to determine the effect of restricted vision and range of motion (ROM) of the knee joint on gait properties while walking and ascending or descending stairs. Fifteen healthy young adults performed level walking and stair ascent and descent during control, vision restriction, and knee joint ROM restriction conditions. During level walking, walking speed and step width decreased, and double support time increased significantly with vision and knee joint ROM restrictions. Stance time, step width, and walking angle increased only with knee joint ROM restriction. Stance time, swing time, and double support time were significantly longer in level walking, stair descent, and stair ascent, in that order. The effects of vision and knee joint ROM restrictions were significantly larger than the control conditions. In conclusion, vision and knee joint ROM restrictions affect gait during level walking and stair ascent and descent. This effect is marked in stair ascent with knee joint ROM restriction.

  9. Normal functional range of motion of the cervical spine during 15 activities of daily living.

    PubMed

    Bible, Jesse E; Biswas, Debdut; Miller, Christopher P; Whang, Peter G; Grauer, Jonathan N

    2010-02-01

    Prospective clinical study. The purpose of this investigation was to quantify normal cervical range of motion (ROM) and compare these results to those used to perform 15 simulated activities of daily living (ADLs) in asymptomatic subjects. Previous studies looking at cervical ROM during ADLs have been limited and used measuring devices that do not record continuous motion. The purpose of this investigation was to quantify normal cervical ROM and compare these results with those used to perform 15 simulated ADLs in asymptomatic subjects. A noninvasive electrogoniometer and torsiometer were used to measure the ROM of the cervical spine. The accuracy and reliability of the devices were confirmed by comparing the ROM values acquired from dynamic flexion/extension and lateral bending radiographs to those provided by the device, which was activated while the radiographs were obtained. Intraobserver reliability was established by calculating the intraclass correlation coefficient for repeated measurements on the same subjects by 1 investigator on consecutive days. These tools were employed in a clinical laboratory setting to evaluate the full active ROM of the cervical spines (ie, flexion/extension, lateral bending, and axial rotation) of 60 asymptomatic subjects (30 females and 30 males; age, 20 to 75 y) as well as to assess the functional ROM required to complete 15 simulated ADLs. When compared with radiographic measurements, the electrogoniometer was found to be accurate within 2.3+/-2.2 degrees (mean+/-SD) and the intraobserver reliabilities for measuring the full active and functional ROM were both excellent (intraclass correlation coefficient of 0.96 and 0.92, respectively). The absolute ROM and percentage of full active cervical spinal ROM used during the 15 ADLs was 13 to 32 degrees and 15% to 32% (median, 20 degrees/19%) for flexion/extension, 9 to 21 degrees and 11% to 27% (14 degrees/18%) for lateral bending, and 13 to 57 degrees and 12% to 92% (18 degrees/19%) for rotation. Backing up a car required the most ROM of all the ADLs, involving 32% of sagittal, 26% of lateral, and 92% of rotational motion. In general, personal hygiene ADLs such as washing hands and hair, shaving, and applying make-up entailed a significantly greater ROM relative to locomotive ADLs including walking and traveling up and down a set of stairs (P<0.0001); in addition, compared with climbing up these steps, significantly more sagittal and rotational motion was used when descending stairs (P=0.003 and P=0.016, respectively). When picking up an object from the ground, a squatting technique required a lower percentage of lateral and rotational ROM than bending at the waist (P=0.002 and P<0.0001). By quantifying the amounts of cervical motion required to execute a series of simulated ADLs, this study indicates that most individuals use a relatively small percentage of their full active ROM when performing such activities. These findings provide baseline data which may allow clinicians to accurately assess preoperative impairment and postsurgical outcomes.

  10. [LOCATION CHANGE OF ROTATION CENTER AFTER SINGLE SEGMENTAL CERVICAL DISC REPLACEMENT WITH ProDisc-C].

    PubMed

    Lou, Jigang; Liu, Hao; Rong, Xin; Gong, Quan; Song, Yueming; Li, Tao

    2015-01-01

    To evaluate the effectiveness of the single segmental cervical disc replacement with ProDisc-C, and to explore the location change of the flexion/extension center of rotation (COR) of the target level as well as its clinical significance. Between June 2010 and February 2012, 23 patients underwent single segmental cervical disc replacement with ProDisc-C, and the clinical data were retrospectively analyzed. Of 23 patients, 9 were male, and 14 were female with the age range from 27 to 65 years (mean, 45 years), and the disease duration ranged from 10 to 84 months (mean, 25 months). There were 15 patients with radiculopathy, 5 patients with myelopathy, and 3 patients with mixed cervical spondylosis. The involved segments were C4,5 in 5 cases, C5,6 in 14 cases, and C6,7 in 4 cases. Japanese Orthopaedic Association (JOA) score and neck disability index (NDI) were adopted to evaluate the effectiveness. Preoperative and Postoperative radiographic parameters, such as cervical overall range of motion (ROM), target segmental ROM, the adjacent segmental ROM, and intervertebral height were compared. Besides, the location changes of the COR of the target level were further analyzed by the alteration of its coordinates (COR-X, COR-Y), and the relationships between the location changes of the COR and the effectiveness or the radiographic results were analyzed. All the operations were completed successfully; 1 case had hoarseness after operation, which disappeared at 3 months after operation. All cases were followed up 18.3 months on average (range, 6-36 months). There was no device migration, loosening, subsidence, or fracture at last follow-up. The JOA score increased significantly and the NDI score decreased significantly at last follow-up when compared with preoperative scores (P < 0.05). No difference was found in the cervical overall ROM, target segmental ROM, the adjacent segmental ROM, and the COR-Y of the target level between pre-operation and last follow-up (P > 0.05); while the intervertebral height and the COR-X increased significantly (P < 0.05). The change of the COR-X had no obvious correlation with the postoperative JOA, NDI, and target segmental ROM (P > 0.05). According to whether the difference of the COR-X between pre- and post-operation was less than the average value 1.86 mm or not, the patients were divided into 2 groups; significant difference was shown in the postoperative target segmental ROM between 2 groups (P < 0.05), but no significant difference was found in the postoperative JOA, NDI, cervical overall ROM, adjacent segmental ROM, and the intervertebral height between 2 groups (P > 0.05). Single segmental cervical disc replacement with ProDisc-C can obtain satisfactory outcomes. The cervical overall ROM, target segmental ROM, and adjacent segmental ROM can be effectively maintained, and the intervertebral height is increased. The location of the flexion/extension COR of the target segment shifts forward after insertion of the ProDisc-C prosthesis, and the postoperative target segmental ROM becomes smaller as the distance of the displacement of the COR becomes greater.

  11. Shared Decision Making in mental health care using Routine Outcome Monitoring as a source of information: a cluster randomised controlled trial.

    PubMed

    Metz, Margot J; Franx, Gerdien C; Veerbeek, Marjolein A; de Beurs, Edwin; van der Feltz-Cornelis, Christina M; Beekman, Aartjan T F

    2015-12-15

    Shared Decision Making (SDM) is a way to empower patients when decisions are made about treatment. In order to be effective agents in this process, patients need access to information of good quality. Routine Outcome Monitoring (ROM) may provide such information and therefore may be a key element in SDM. This trial tests the effectiveness of SDM using ROM, primarily aiming to diminish decisional conflict of the patient while making decisions about treatment. The degree of decisional conflict, the primary outcome of this study, encompasses personal certainty about choosing an appropriate treatment, information about options, clarification of patient values, support from others and patients experience of an effective decision making process. Secondary outcomes of the study focus on the working alliance between patient and clinician, adherence to treatment, and clinical outcome and quality of life. This article presents the study protocol of a multi-centre two-arm cluster randomised controlled trial (RCT). The research is conducted in Dutch specialised mental health care teams participating in the ROM Quality Improvement Collaborative (QIC), which aims to implement ROM in daily clinical practice. In the intervention teams, ROM is used as a source of information during the SDM process between the patient and clinician. Control teams receive no specific SDM or ROM instructions and apply decision making as usual. Randomisation is conducted at the level of the participating teams within the mental health organisations. A total of 12 teams from 4 organisations and 364 patients participate in the study. Prior to data collection, the intervention teams are trained to use ROM during the SDM process. Data collection will be at baseline, and at 3 and 6 months after inclusion of the patient. Control teams will implement the SDM and ROM model after completion of the study. This study will provide useful information about the effectiveness of ROM within a SDM framework. Furthermore, with practical guidelines this study may contribute to the implementation of SDM using ROM in mental health care. Reporting of the results is expected from December 2016 onwards. Dutch trial register: TC5262. Trial registration date: 24th of June 2015.

  12. Fabrication and electrical characterization of a MOS memory device containing self-assembled metallic nanoparticles

    NASA Astrophysics Data System (ADS)

    Sargentis, Ch.; Giannakopoulos, K.; Travlos, A.; Tsamakis, D.

    2007-04-01

    Floating gate devices with nanoparticles embedded in dielectrics have recently attracted much attention due to the fact that these devices operate as non-volatile memories with high speed, high density and low power consumption. In this paper, memory devices containing gold (Au) nanoparticles have been fabricated using e-gun evaporation. The Au nanoparticles are deposited on a very thin SiO 2 layer and are then fully covered by a HfO 2 layer. The HfO 2 is a high- k dielectric and gives good scalability to the fabricated devices. We studied the effect of the deposition parameters to the size and the shape of the Au nanoparticles using capacitance-voltage and conductance-voltage measurements, we demonstrated that the fabricated device can indeed operate as a low-voltage memory device.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, H. X.; Zhang, T.; Wang, R. X.

    A nano-floating gate memory structure based on Ni nanocrystals (NCs) embedded HfO{sub x} film is deposited by means of radio-frequency magnetron sputtering. Microstructure investigations reveal that self-organized Ni-NCs with diameters of 4-8 nm are well dispersed in amorphous HfO{sub x} matrix. Pt/Ni-NCs embedded HfO{sub x}/Si/Ag capacitor structures exhibit voltage-dependent capacitance-voltage hysteresis, and a maximum flat-band voltage shift of 1.5 V, corresponding to a charge storage density of 6.0 × 10{sup 12} electrons/cm{sup 2}, is achieved. These capacitor memory cells exhibit good endurance characteristic up to 4 × 10{sup 4} cycles and excellent retention performance of 10{sup 5} s, fulfilling themore » requirements of next generation non-volatile memory devices. Schottky tunneling is proven to be responsible for electrons tunneling in these capacitors.« less

  14. Optimization of a PCRAM Chip for high-speed read and highly reliable reset operations

    NASA Astrophysics Data System (ADS)

    Li, Xiaoyun; Chen, Houpeng; Li, Xi; Wang, Qian; Fan, Xi; Hu, Jiajun; Lei, Yu; Zhang, Qi; Tian, Zhen; Song, Zhitang

    2016-10-01

    The widely used traditional Flash memory suffers from its performance limits such as its serious crosstalk problems, and increasing complexity of floating gate scaling. Phase change random access memory (PCRAM) becomes one of the most potential nonvolatile memories among the new memory techniques. In this paper, a 1M-bit PCRAM chip is designed based on the SMIC 40nm CMOS technology. Focusing on the read and write performance, two new circuits with high-speed read operation and highly reliable reset operation are proposed. The high-speed read circuit effectively reduces the reading time from 74ns to 40ns. The double-mode reset circuit improves the chip yield. This 1M-bit PCRAM chip has been simulated on cadence. After layout design is completed, the chip will be taped out for post-test.

  15. Recent Advances of Flexible Data Storage Devices Based on Organic Nanoscaled Materials.

    PubMed

    Zhou, Li; Mao, Jingyu; Ren, Yi; Han, Su-Ting; Roy, Vellaisamy A L; Zhou, Ye

    2018-03-01

    Following the trend of miniaturization as per Moore's law, and facing the strong demand of next-generation electronic devices that should be highly portable, wearable, transplantable, and lightweight, growing endeavors have been made to develop novel flexible data storage devices possessing nonvolatile ability, high-density storage, high-switching speed, and reliable endurance properties. Nonvolatile organic data storage devices including memory devices on the basis of floating-gate, charge-trapping, and ferroelectric architectures, as well as organic resistive memory are believed to be favorable candidates for future data storage applications. In this Review, typical information on device structure, memory characteristics, device operation mechanisms, mechanical properties, challenges, and recent progress of the above categories of flexible data storage devices based on organic nanoscaled materials is summarized. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Charge storage and tunneling mechanism of Ni nanocrystals embedded HfOx film

    NASA Astrophysics Data System (ADS)

    Zhu, H. X.; Zhang, T.; Wang, R. X.; Zhang, Y. Y.; Li, L. T.; Qiu, X. Y.

    2016-05-01

    A nano-floating gate memory structure based on Ni nanocrystals (NCs) embedded HfOx film is deposited by means of radio-frequency magnetron sputtering. Microstructure investigations reveal that self-organized Ni-NCs with diameters of 4-8 nm are well dispersed in amorphous HfOx matrix. Pt/Ni-NCs embedded HfOx/Si/Ag capacitor structures exhibit voltage-dependent capacitance-voltage hysteresis, and a maximum flat-band voltage shift of 1.5 V, corresponding to a charge storage density of 6.0 × 1012 electrons/cm2, is achieved. These capacitor memory cells exhibit good endurance characteristic up to 4 × 104 cycles and excellent retention performance of 105 s, fulfilling the requirements of next generation non-volatile memory devices. Schottky tunneling is proven to be responsible for electrons tunneling in these capacitors.

  17. CMOS Image Sensor Using SOI-MOS/Photodiode Composite Photodetector Device

    NASA Astrophysics Data System (ADS)

    Uryu, Yuko; Asano, Tanemasa

    2002-04-01

    A new photodetector device composed of a lateral junction photodiode and a metal-oxide-semiconductor field-effect-transistor (MOSFET), in which the output of the diode is fed through the body of the MOSFET, has been investigated. It is shown that the silicon-on-insulator (SOI)-MOSFET amplifies the junction photodiode current due to the lateral bipolar action. It is also shown that the presence of the electrically floating gate enhances the current amplification factor of the SOI-MOSFET. The output current of this composite device linearly responds by four orders of illumination intensity. As an application of the composite device, a complementary-metal-oxide-semiconductor (CMOS) line sensor incorporating the composite device is fabricated and its operation is demonstrated. The output signal of the line sensor using the composite device was two times larger than that using the lateral photodiode.

  18. The Effectiveness of PNF Versus Static Stretching on Increasing Hip-Flexion Range of Motion.

    PubMed

    Lempke, Landon; Wilkinson, Rebecca; Murray, Caitlin; Stanek, Justin

    2018-05-22

    Clinical Scenario: Stretching is applied for the purposes of injury prevention, increasing joint range of motion (ROM), and increasing muscle extensibility. Many researchers have investigated various methods and techniques to determine the most effective way to increase joint ROM and muscle extensibility. Despite the numerous studies conducted, controversy still remains within clinical practice and the literature regarding the best methods and techniques for stretching. Focused Clinical Question: Is proprioceptive neuromuscular facilitation (PNF) stretching more effective than static stretching for increasing hamstring muscle extensibility through increased hip ROM or increased knee extension angle (KEA) in a physically active population? Summary of Key Findings: Five studies met the inclusion criteria and were included. All 5 studies were randomized control trials examining mobility of the hamstring group. The studies measured hamstring ROM in a variety of ways. Three studies measured active KEA, 1 study measured passive KEA, and 1 study measured hip ROM via the single-leg raise test. Of the 5 studies, 1 study found greater improvements using PNF over static stretching for increasing hip flexion, and the remaining 4 studies found no significant difference between PNF stretching and static stretching in increasing muscle extensibility, active KEA, or hip ROM. Clinical Bottom Line: PNF stretching was not demonstrated to be more effective at increasing hamstring extensibility compared to static stretching. The literature reviewed suggests both are effective methods for increasing hip-flexion ROM. Strength of Recommendation: Using level 2 evidence and higher, the results show both static and PNF stretching effectively increase ROM; however, one does not appear to be more effective than the other.

  19. [Changes of crop yield and soil fertility under long-term fertilization and nutrients-recycling and reutilization on a black soil: IV. Soil organic carbon and its fractions].

    PubMed

    Zhao, Lijuan; Whan, Xiaozeng; Wang, Shouyu; Liu, Hongxiang; Li, Haibo; Miao, Shujie; Ang, Feng

    2006-05-01

    A long-term experiment was conducted on a black soil of Northeast China to study the effects of applying chemical fertilizers and recycled organic manure (ROM) on the changes of soil organic carbon and its fractions. The results showed that from 1985 to 2004, soil total organic carbon (TOC) decreased by 7.83% in control,4.56% in N application, 1.61% in N + P application, and 5.56% in ROM application, but increased by 0.33% in N + P + K application. Comparing with single application of ROM, its application with chemical fertilizers, i. e., N + ROM, N + P + ROM, and N + P + K + ROM, increased the TOC concentration by 0.35%, 1.05% and 0.64%, respectively. The readily oxidized carbon (ROC) in fertilization treatments was increased by 8.64% to approximately 28.4%, and the increment was higher in treatments of chemical fertilizers plus ROM than in treatments of chemical fertilizers. The ROC was significantly correlated with soil TOC (Y = 14.192X + 23.9, R2 = 0.802) and stalk yields (Y = 19032X - 7950.6, R2 = 0.759). Light fraction organic carbon (LF-C) had the same trends with ROC. After 20 years fertilization, the organic carbon in soil humic acid and fulvic acid was decreased by 1.64% to approximately 26.23% and 2.33% to approximately 28.68%, respectively, but in treatments of chemical fertilizers plus ROM, the decreasing trend was slowed down.

  20. The Business and Technology of Electronic and Optical Publishing.

    ERIC Educational Resources Information Center

    Schwerin, Julie B.

    1988-01-01

    The first of a two-part series on the emergence of CD-ROM in the online publishing industry introduces the business and technology aspects of electronic and optical publishing. The development of CD-ROM products and differences between CD-ROM and online in the areas of technology, content, and marketing are discussed. (MES)

  1. Protecting Your Environment: An Interactive CD-ROM. [CD-ROM].

    ERIC Educational Resources Information Center

    Ohio Environmental Protection Agency, Columbus. Office of Environmental Education.

    This interactive CD-ROM provides an overview of the environmental risks in Ohio and makes recommendations on how to reduce these risks on individual and community bases. The main menu is divided into three sections that include sub categories. Section A, "Understanding Your Environment," includes: (1) "Air We Breathe"; (2)…

  2. Food Chains & Webs. A Multimedia CD-ROM. [CD-ROM].

    ERIC Educational Resources Information Center

    2001

    This CD-ROM is designed for classroom and individual use to teach and learn about food chains and food webs. Integrated animations, custom graphics, three-dimensional representations, photographs, and sound are featured for use in user-controlled activities. Interactive lessons are available to reinforce the subject material. Pre- and post-testing…

  3. Energy & Environmental Issues Interactive CD-ROM. Version 2.0. [CD-ROM].

    ERIC Educational Resources Information Center

    Florida State Univ., Tallahassee.

    This CD-ROM presents various energy and environmental topics. "Great Energy Debate" uses video clips to explore the pros and cons of solar, coal, nuclear, and oil energy sources. "Energy Plant Tour" presents a virtual tour through a plant that converts solid waste into energy. "How Stuff Works" explains energy…

  4. Publishing Your Database on CD-ROM for Profit: The FISHLIT and NISC Experience.

    ERIC Educational Resources Information Center

    Crampton, Margaret

    1995-01-01

    Details the development of the FISHLIT bibliographic database at the JLB Smith Institute of Ichthyology Library at Rhodes University (South Africa), and the subsequent CD-ROM publication of the database by NISC (National Information Services Corporation). Discusses the advantages of CD-ROM publication, costs and information service provision,…

  5. File Server-Based CD-ROM Networking: Using SCSI Express.

    ERIC Educational Resources Information Center

    McQueen, Howard

    1992-01-01

    Provides guidelines for evaluating SCSI Express Novell 386, a new product allowing CD-ROM drives to be attached to a Netware 3.11 file server, increasing CD-ROM networking capability. Specific limitations concerning software, hardware, and human resources are outlined, as well as its unique features and potential for future networking uses. (EA)

  6. A Mobile Online/CD-ROM Workstation for Demos and Instruction.

    ERIC Educational Resources Information Center

    Wright, Carol; Friend, Linda

    1991-01-01

    Describes a mobile workstation that was developed at Penn State University to provide library instruction and demonstrations of online and CD-ROM searching. Use of the workstation for classroom instruction and staff training is discussed; and designing the workstation to include a computer, overhead projector, modem, CD-ROM drive, and printer is…

  7. Independent Reading of CD-ROM Storybooks: Measuring Comprehension with Oral Retellings

    ERIC Educational Resources Information Center

    Pearman, Cathy J.

    2008-01-01

    CD-ROM storybooks may facilitate reading comprehension for students who are struggling with reading comprehension. Therefore, the use of CD-ROM storybooks in the classroom as part of a reading instruction program, literacy center, or for independent reading time could benefit young readers. (Contains 2 tables and 1 figure.)

  8. The Sun's Joules. [CD-ROM].

    ERIC Educational Resources Information Center

    Center for Renewable Energy and Sustainable Tech., Washington, DC.

    An educational tool concerning renewable energy and the environment, this CD-ROM provides nearly 1,000 screens of text, graphics, videos, and interactive exercises. It also provides a detailed index, charts of U.S. energy consumption by state, an energy glossary, and a list of related Web sites. This CD-ROM, additionally, offers "The School…

  9. CD-ROMS Step by Step.

    ERIC Educational Resources Information Center

    Nath, Herbert

    This manual consists of sets of guides for six CD-ROM databases: (1) ABI/INFORM, a business administration CD-ROM published by UMI; (2) Books in Print (an outstanding tool for compiling bibliographies on any subject); (3) ERIC (Educational Resources Information Center), an education database in the version published by SilverPlatter; (4) MLA, a…

  10. REGIONAL OXIDANT MODEL (ROM) USER'S GUIDE, PART 2: THE ROM PREPROCESSOR NETWORK

    EPA Science Inventory

    The Regional Oxidant Model (ROM) determines hourly concentrations and fates of zone and 34 other chemical species over a scale of 1000 km x 1000 km for ozone "episodes" of up to one month's duration. he model structure, based on phenomenological concepts, consists of 3 1/2 layers...

  11. Catmull-Rom Curve Fitting and Interpolation Equations

    ERIC Educational Resources Information Center

    Jerome, Lawrence

    2010-01-01

    Computer graphics and animation experts have been using the Catmull-Rom smooth curve interpolation equations since 1974, but the vector and matrix equations can be derived and simplified using basic algebra, resulting in a simple set of linear equations with constant coefficients. A variety of uses of Catmull-Rom interpolation are demonstrated,…

  12. Early Readers and Electronic Texts: CD-ROM Storybook Features That Influence Reading Behaviors

    ERIC Educational Resources Information Center

    Lefever-Davis, Shirley; Pearman, Cathy

    2005-01-01

    This research explores the impact of CD-ROM storybook features on the reading behaviors of 6- and 7-year-old students with limited exposure to CD-ROM storybooks. Six categories of behaviors were identified: tracking, electronic feature dependency, distractibility, spectator stance, electronic feature limitations, and electronic features as tools.…

  13. CD-ROM Technology for Education and Support of Site Supervisors

    ERIC Educational Resources Information Center

    Manzanares, Mark G.; O'Halloran, Theresa M.; McCartney, Teri J.; Filer, Rex D.; Varhely, Susan C.; Calhoun, Ken

    2004-01-01

    In this article, the authors discuss the creation and evaluation of a CD-ROM to train and support prepracticum, practicum, and internship site supervisors in a master's-level counselor education program. The authors, from a small, rural, southwestern college, created and distributed a CD-ROM containing video and document resources for this…

  14. Type 1 Diabetes in Children: A Passport to Knowledge. [CD-ROM].

    ERIC Educational Resources Information Center

    2001

    This educational CD-ROM is designed to provide a working knowledge of diabetes and its effect on children. It is intended for parents, health care professionals, pharmacists, teachers, coaches, and child care providers. The CD-ROM examines issues related to diabetes management (food, insulin, monitoring, hypoglycemia, and illness); lifestyle; and…

  15. Using Newspapers on CD-ROM as a Resource.

    ERIC Educational Resources Information Center

    Seedhouse, Paul

    1996-01-01

    Presents the advantages of using newspapers stored on CD-ROM as a resource for teaching current topics in civilization/culture and current affairs in the foreign- language class. Articles on CD-ROM can be used for vocabulary exercises and comprehension tests, and on-screen text can be altered as desired to create classroom activities. (four…

  16. Development and Utilization of Regional Oceanic Modeling System (ROMS) & Delicacy, Imprecision, and Uncertainty of Oceanic Simulations: An Investigation with ROMS

    DTIC Science & Technology

    2010-09-30

    and Ecosystems: An important community use for ROMS is biogeochemisty: chemical cycles, water quality, blooms , micro-nutrients, larval dispersal... Chile current system. J. Climate, submitted. Colas, F., X. Capet, and J. McWilliams, 2010b: Mesoscale eddy buoyancy flux and eddy-induced

  17. 19 CFR 210.8 - Commencement of preinstitution proceedings.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... electronic form on CD-ROM, DVD, or other portable electronic media approved by the Secretary. (ii) An... CD-ROM, DVD, or other portable electronic media approved by the Secretary. (iii) For each proposed... version of the motion shall be filed in electronic form on CD-ROM, DVD, or other portable electronic media...

  18. 19 CFR 210.8 - Commencement of preinstitution proceedings.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... electronic form on CD-ROM, DVD, or other portable electronic media approved by the Secretary. (ii) An... CD-ROM, DVD, or other portable electronic media approved by the Secretary. (iii) For each proposed... version of the motion shall be filed in electronic form on CD-ROM, DVD, or other portable electronic media...

  19. 19 CFR 210.8 - Commencement of preinstitution proceedings.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... electronic form on CD-ROM, DVD, or other portable electronic media approved by the Secretary. (ii) An... CD-ROM, DVD, or other portable electronic media approved by the Secretary. (iii) For each proposed... version of the motion shall be filed in electronic form on CD-ROM, DVD, or other portable electronic media...

  20. Reflections on CD-ROM: Bridging the Gap between Technology and Purpose.

    ERIC Educational Resources Information Center

    Saviers, Shannon Smith

    1987-01-01

    Provides a technological overview of CD-ROM (Compact Disc-Read Only Memory), an optically-based medium for data storage offering large storage capacity, computer-based delivery system, read-only medium, and economic mass production. CD-ROM database attributes appropriate for information delivery are also reviewed, including large database size,…

  1. Holographic Compact Disk Read-Only Memories

    NASA Technical Reports Server (NTRS)

    Liu, Tsuen-Hsi

    1996-01-01

    Compact disk read-only memories (CD-ROMs) of proposed type store digital data in volume holograms instead of in surface differentially reflective elements. Holographic CD-ROM consist largely of parts similar to those used in conventional CD-ROMs. However, achieves 10 or more times data-storage capacity and throughput by use of wavelength-multiplexing/volume-hologram scheme.

  2. MULTIMEDIA COLLECTION TO AN ORGANIZATIONAL GUIDE TO POLLUTION PREVENTION ( DVD-ROM ); WORKSHOP SERIES, MANUAL, SUPPLEMENTAL CD

    EPA Science Inventory

    This Multimedia Collection to An Organizational Guide to Pollution Prevention (DVD-ROM) provides videos and slides of a three-day workshop series conducted in each of the ten US EPA Regions, and is based on the publication An Organizational Guide to Pollution Prevention CD-ROM (E...

  3. DNA: The Molecule of Life. A Multimedia CD-ROM. [CD-ROM].

    ERIC Educational Resources Information Center

    2001

    This CD-ROM is designed for classroom and individual use to teach and learn about DNA. Integrated animations, custom graphics, three-dimensional representations, photographs, and sound are featured for use in user-controlled activities. Interactive lessons are available to reinforce the subject material. Pre- and post-testing sections are also…

  4. New Access Points to ERIC--CD-ROM Versions. ERIC Digest.

    ERIC Educational Resources Information Center

    McLaughlin, Pamela W.

    This digest reviews three CD-ROM (compact disc-read only memory) versions of the ERIC (Educational Resources Information Center) database currently being delivered or tested and provides information for comparison. However, no attempt is made to recommend any one product. The advantages and disadvantages of the acquisition of CD-ROM databases are…

  5. Learning about Palau. [CD-ROM].

    ERIC Educational Resources Information Center

    Pacific Resources for Education and Learning, Honolulu, HI.

    This CD-ROM contains information about the Republic of Palau, a sovereign state in the Pacific Ocean. The CD-ROM contains full-color photos and video clips of selected sites and events on Palau; interactive maps of Palau, including land forms, places of cultural significance, and public schools; and a glossary of geographic, geological, and…

  6. C-reactive protein and reactive oxygen metabolites in subjects with metabolic syndrome.

    PubMed

    Kotani, K; Sakane, N

    2012-01-01

    This cross-sectional study investigated the correlation between diacron reactive oxygen metabolites (d-ROMs) and high-sensitivity C-reactive protein (hs-CRP) in subjects with or without metabolic syndrome. Cardiometabolic risk factors, d-ROMs and hs-CRP were determined in 457 women: 123 with metabolic syndrome and 334 without metabolic syndrome. The correlation between d-ROMs and hs-CRP levels was compared between the two groups. The group with metabolic syndrome had significantly higher d-ROMs and hs-CRP levels than the group without metabolic syndrome. While the d-ROMs level was significantly and positively correlated with the hs-CRP level in both groups, the correlation level between the two groups was significantly different. Multiple linear regression analysis adjusted for other cardiometabolic risk factors also showed significant positive correlation between dROMs and hs-CRP levels in both groups. Subjects with metabolic syndrome may have a closer relationship between inflammation and oxidative stress than subjects without metabolic syndrome, possibly reflecting their increased predisposition to atherosclerosis. Further studies are necessary to confirm the observed relationship.

  7. Reduced Order Modeling for Prediction and Control of Large-Scale Systems.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalashnikova, Irina; Arunajatesan, Srinivasan; Barone, Matthew Franklin

    2014-05-01

    This report describes work performed from June 2012 through May 2014 as a part of a Sandia Early Career Laboratory Directed Research and Development (LDRD) project led by the first author. The objective of the project is to investigate methods for building stable and efficient proper orthogonal decomposition (POD)/Galerkin reduced order models (ROMs): models derived from a sequence of high-fidelity simulations but having a much lower computational cost. Since they are, by construction, small and fast, ROMs can enable real-time simulations of complex systems for onthe- spot analysis, control and decision-making in the presence of uncertainty. Of particular interest tomore » Sandia is the use of ROMs for the quantification of the compressible captive-carry environment, simulated for the design and qualification of nuclear weapons systems. It is an unfortunate reality that many ROM techniques are computationally intractable or lack an a priori stability guarantee for compressible flows. For this reason, this LDRD project focuses on the development of techniques for building provably stable projection-based ROMs. Model reduction approaches based on continuous as well as discrete projection are considered. In the first part of this report, an approach for building energy-stable Galerkin ROMs for linear hyperbolic or incompletely parabolic systems of partial differential equations (PDEs) using continuous projection is developed. The key idea is to apply a transformation induced by the Lyapunov function for the system, and to build the ROM in the transformed variables. It is shown that, for many PDE systems including the linearized compressible Euler and linearized compressible Navier-Stokes equations, the desired transformation is induced by a special inner product, termed the “symmetry inner product”. Attention is then turned to nonlinear conservation laws. A new transformation and corresponding energy-based inner product for the full nonlinear compressible Navier-Stokes equations is derived, and it is demonstrated that if a Galerkin ROM is constructed in this inner product, the ROM system energy will be bounded in a way that is consistent with the behavior of the exact solution to these PDEs, i.e., the ROM will be energy-stable. The viability of the linear as well as nonlinear continuous projection model reduction approaches developed as a part of this project is evaluated on several test cases, including the cavity configuration of interest in the targeted application area. In the second part of this report, some POD/Galerkin approaches for building stable ROMs using discrete projection are explored. It is shown that, for generic linear time-invariant (LTI) systems, a discrete counterpart of the continuous symmetry inner product is a weighted L2 inner product obtained by solving a Lyapunov equation. This inner product was first proposed by Rowley et al., and is termed herein the “Lyapunov inner product“. Comparisons between the symmetry inner product and the Lyapunov inner product are made, and the performance of ROMs constructed using these inner products is evaluated on several benchmark test cases. Also in the second part of this report, a new ROM stabilization approach, termed “ROM stabilization via optimization-based eigenvalue reassignment“, is developed for generic LTI systems. At the heart of this method is a constrained nonlinear least-squares optimization problem that is formulated and solved numerically to ensure accuracy of the stabilized ROM. Numerical studies reveal that the optimization problem is computationally inexpensive to solve, and that the new stabilization approach delivers ROMs that are stable as well as accurate. Summaries of “lessons learned“ and perspectives for future work motivated by this LDRD project are provided at the end of each of the two main chapters.« less

  8. Development and test of a model for designing interactive CD-ROMs for teaching nursing skills.

    PubMed

    Jeffries, P R

    2000-01-01

    The use of interactive multimedia is well documented in the education literature as a medium for learning. Many schools of nursing and healthcare agencies purchase commercially-made CD-ROM products, and, in other cases, educators develop their own. Since nurses are increasingly designing CD-ROMs, they must be aware of the instructional design needed to develop comprehensive and effective CD-ROMs that do not compromise the quality of education. This article describes a process for developing and testing an interactive, multimedia CD-ROM on oral medication administration, using an instructional design model based on Chickering and Gamson's Principles of Good Practices in Education. Results from testing the model are reported. The findings can be used to guide the work of nurse educators who are interested in developing educational software.

  9. Numerical Modeling of ROM Panel Closures at WIPP

    NASA Astrophysics Data System (ADS)

    Herrick, C. G.

    2016-12-01

    The Waste Isolation Pilot Plant (WIPP) in New Mexico is a U.S. DOE geologic repository for permanent disposal of defense-related transuranic (TRU) waste. Waste is emplaced in panels excavated in a bedded salt formation (Salado Fm.) at 655 m bgs. In 2014 the U.S. EPA approved the new Run-of-Mine Panel Closure System (ROMPCS) for WIPP. The closure system consists of 100 feet of run-of-mine (ROM) salt sandwiched between two barriers. Nuclear Waste Partnership LLC (the M&O contractor for WIPP) initiated construction of the ROMPCS. The design calls for three horizontal ROM salt layers at different compaction levels ranging from 70-85% intact salt density. Due to panel drift size constraints and equipment availability the design was modified. Three prototype panel closures were constructed: two having two layers of compacted ROM salt (one closure had 1% water added) and a third consisting of simply ROM salt with no layering or added water. Sampling of the prototype ROMPCS layers was conducted to determine the following ROM salt parameters: thickness, moisture content, emplaced density, and grain-size distribution. Previous modeling efforts were performed without knowledge of these ROM salt parameters. This modeling effort incorporates them. The program-accepted multimechanism deformation model is used to model intact salt room creep closure. An advanced crushed salt model is used to model the ROM salt. Comparison of the two models' results with the prototypes' behavior is given. Our goal is to develop a realistic, reliable model that can be used for ROM salt applications at WIPP. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U. S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000. This research is funded by WIPP programs administered by the Office of Environmental Management (EM) of the U.S Department of Energy SAND2016-7259A

  10. Sagittal range of motion of the thoracic spine using inertial tracking device and effect of measurement errors on model predictions.

    PubMed

    Hajibozorgi, M; Arjmand, N

    2016-04-11

    Range of motion (ROM) of the thoracic spine has implications in patient discrimination for diagnostic purposes and in biomechanical models for predictions of spinal loads. Few previous studies have reported quite different thoracic ROMs. Total (T1-T12), lower (T5-T12) and upper (T1-T5) thoracic, lumbar (T12-S1), pelvis, and entire trunk (T1) ROMs were measured using an inertial tracking device as asymptomatic subjects flexed forward from their neutral upright position to full forward flexion. Correlations between body height and the ROMs were conducted. An effect of measurement errors of the trunk flexion (T1) on the model-predicted spinal loads was investigated. Mean of peak voluntary total flexion of trunk (T1) was 118.4 ± 13.9°, of which 20.5 ± 6.5° was generated by flexion of the T1 to T12 (thoracic ROM), and the remaining by flexion of the T12 to S1 (lumbar ROM) (50.2 ± 7.0°) and pelvis (47.8 ± 6.9°). Lower thoracic ROM was significantly larger than upper thoracic ROM (14.8 ± 5.4° versus 5.8 ± 3.1°). There were non-significant weak correlations between body height and the ROMs. Contribution of the pelvis to generate the total trunk flexion increased from ~20% to 40% and that of the lumbar decreased from ~60% to 42% as subjects flexed forward from upright to maximal flexion while that of the thoracic spine remained almost constant (~16% to 20%) during the entire movement. Small uncertainties (±5°) in the measurement of trunk flexion angle resulted in considerable errors (~27%) in the model-predicted spinal loads only in activities involving small trunk flexion. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. The Effect of Supination and Pronation on Wrist Range of Motion

    PubMed Central

    Kane, Patrick M.; Vopat, Bryan G.; Got, Christopher; Mansuripur, Kaveh; Akelman, Edward

    2014-01-01

    Wrist range of motion (ROM) is a combination of complex osseous articulations and intricate soft tissue constraints. It has been proposed that forearm rotation contributes significantly to carpal kinematics. However, no studies have investigated whether supination or pronation influence this course of motion. The purpose of this study is to examine whether supination and pronation affect the mechanical axis of the wrist. After being screened for gross anatomic abnormalities, six upper extremity cadaver specimens (three matched pairs) were fixed to a custom-designed jig that allows 24 different directions of wrist motion. Each specimen was tested in three separate forearm positions: neutral, full supination, and full pronation. Moments of ± 2 Nm were applied, and the applied moment versus wrist rotation data were recorded. Forearm position did not significantly (p > 0.31) affect the ROM values of the wrist. In forearm neutral, supination, and pronation positions the envelope of wrist ROM values was ellipsoidal in shape, consistent with prior neutral forearm biomechanical testing. The major axis of the ellipse was oriented in a radial extension to ulnar flexion direction, with the largest ROM in ulnar flexion. We hypothesized that forearm position would influence wrist ROM. However, our biomechanical testing showed no statistically significant difference in the orientation of the mechanical axis nor the passive ROM of the wrist. The primary passive mechanical axis in all three forearm positions tested (neutral, supination, and pronation) was aligned with radial extension and ulnar flexion. Although it has been shown that forearm position affects various radioulnar, radiocarpal, and ulnocarpal ligamentous tensions and lengths, it appears that wrist ROM is independent of forearm position. Consequently we feel our biomechanical testing illustrates that wrist ROM is primarily dependent on the osseous articulations of the carpus. Additionally, given that no change is observed in wrist ROM relative to forearm position, the significance of the contribution of the distal radioulnar joint (DRUJ) to wrist kinematics is debatable. PMID:25097812

  12. Efficacy of the Reactive Oxygen Metabolite Test as a Predictor of Initial Heart Failure Hospitalization in Elderly Patients With Chronic Heart Failure.

    PubMed

    Hitsumoto, Takashi

    2018-06-01

    The reactive oxygen metabolites (d-ROMs) test has recently been explored as a novel marker of oxidative stress in vivo and used in clinical settings. Conversely, data regarding the utility of the d-ROMs test as a predictor of patients with chronic heart failure (CHF) are limited. This prospective study aims to elucidate the efficacy of the d-ROMs test as a predictor of initial heart failure (HF) hospitalization in elderly patients with CHF. A total of 428 elderly outpatients with CHF with no history of HF hospitalization (108 males, 320 females; mean age, 75 ± 7 years) were enrolled. Based on the median value of d-ROMs test levels (303 U.CARR), the patients were divided into the following two groups: group L (low d-ROMs test levels) and group H (high d-ROMs test levels). The utility of the d-ROMs test as a predictor of initial HF hospitalization was evaluated. During the 88.1-month follow-up period, 58 HF cases were hospitalized (group L, 17 cases; group H, 41 cases; P < 0.001, log-rank test). Multivariate Cox regression analyses revealed that group H exhibited a significantly higher risk for HF hospitalization than did group L (hazard ratio (HR), 2.35; 95% confidence interval (CI), 1.37 - 4.43; P < 0.01). Furthermore, the HR (vs. group L with low brain natriuretic peptide (BNP) levels (< 200 pg/mL), HR, 9.18; 95% CI, 4.78 - 22.94; P < 0.001) for the incidence of HF hospitalization increased in group H with high BNP levels (≥ 200 pg/mL). The present study demonstrates that high d-ROMs test levels predict initial HF hospitalization in elderly patients with CHF. In addition, the predictive value for the incidence of HF hospitalization increases by using a combination of two biomarkers as d-ROMs test and BNP levels.

  13. Spectral analysis of one-way and two-way downscaling applications for a tidally driven coastal ocean forecasting system

    NASA Astrophysics Data System (ADS)

    Solano, Miguel; Gonzalez, Juan; Canals, Miguel; Capella, Jorge; Morell, Julio; Leonardi, Stefano

    2017-04-01

    A prevailing problem for a tidally driven coastal ocean has been the adequate imposition of open boundary conditions. This study aims at assessing the role of open boundary conditions and tidal forcing for one and two way downscaling applications at high resolution. The operational system is based on the Caribbean Coastal Ocean Forecasting System (COFS) that uses the Regional Ocean Modeling System (ROMS), a split-explicit ocean model in which the barotropic (2D) and baroclinic (3D) modes advance separately. This COFS uses a uniform horizontal grid with 1km resolution, but a grid sensitivity analysis is performed for both one and two way downscaling methodologies with horizontal resolutions up to 700m. Initial and lateral boundary conditions are derived from the U.S Naval Oceanographic Office (NAVOCEANO) operational AmSeas model forecast, a 3-km resolution of the regional Navy Coastal Ocean Model (NCOM) that encompasses the Gulf of Mexico and Caribbean Sea. Meteorological conditions are interpolated from the Navy's COAMPS model with the exception of surface stresses, which are computed from a 2-km application of the WRF model used by NCEP's National Digital Forecast Database. Tidal forcing is performed in two different ways: 1) tidal and sub-tidal variability is imposed to the barotropic and baroclinic modes by downscaling from the AmSeas NCOM regional model and 2) tidal variability is imposed using ROMS harmonic tidal forcing from OTPS and sub-tidal conditions are imposed by filtering high frequencies out the NCOM regional solution. Special focus is given to the latter approach, where the nudging time scales and the boundary update frequency play an important role in the evolution of the ocean state for short 3-day forecasts. A spectral analysis of the sea surface height and barotropic velocity is performed via Fourier's transform, continuous 1-D wavelet transforms, and classic harmonic analysis. Tide signals are then reconstructed and removed from the OBC's in 3 ways: 1) using Rich Pawlowicz's t_tide package (classic harmonic analysis), 2) with traditional band-pass filters (e.g. Lanczos) and 3) using Proper Orthogonal Decomposition. The tide filtering approach shows great improvement in the high frequency response of tidal motions at the open boundaries. Results are validated with NOAA tide gauges, Acoustic Doppler Current Profilers, High Frequency Radars (6km and 2km resolution). A floating drifter experiment is performed in coastal zones, in which 12 drifters were deployed at different coastal zones and tracked for several days. The results show an improvement of the forecast skill with the proper implementation of the tide filtering approach by adjusting the nudging time scales and adequately removing the tidal signals. Significant improvement is found in the tracking skill of the floating drifters for the one-way grid and the two-way nested application also shows some improvement over the offline downscaling approach at higher resolutions.

  14. Reference System of DNA and Protein Sequences on CD-ROM

    NASA Astrophysics Data System (ADS)

    Nasu, Hisanori; Ito, Toshiaki

    DNASIS-DBREF31 is a database for DNA and Protein sequences in the form of optical Compact Disk (CD) ROM, developed and commercialized by Hitachi Software Engineering Co., Ltd. Both nucleic acid base sequences and protein amino acid sequences can be retrieved from a single CD-ROM. Existing database is offered in the form of on-line service, floppy disks, or magnetic tape, all of which have some problems or other, such as usability or storage capacity. DNASIS-DBREF31 newly adopt a CD-ROM as a database device to realize a mass storage and personal use of the database.

  15. Effects of Baseline Levels of Flexibility and Vertical Jump Ability on Performance Following Different Volumes of Static Stretching and Potentiating Exercises in Elite Gymnasts

    PubMed Central

    Donti, Olyvia; Tsolakis, Charilaos; Bogdanis, Gregory C.

    2014-01-01

    This study examined the effects of baseline flexibility and vertical jump ability on straight leg raise range of motion (ROM) and counter-movement jump performance (CMJ) following different volumes of stretching and potentiating exercises. ROM and CMJ were measured after two different warm-up protocols involving static stretching and potentiating exercises. Three groups of elite athletes (10 male, 14 female artistic gymnasts and 10 female rhythmic gymnasts) varying greatly in ROM and CMJ, performed two warm-up routines. One warm-up included short (15 s) static stretching followed by 5 tuck jumps, while the other included long static stretching (30 s) followed by 3x5 tuck jumps. ROM and CMJ were measured before, during and for 12 min after the two warm-up routines. Three-way ANOVA showed large differences between the three groups in baseline ROM and CMJ performance. A type of warm-up x time interaction was found for both ROM (p = 0.031) and CMJ (p = 0.016). However, all athletes, irrespective of group, responded in a similar fashion to the different warm-up protocols for both ROM and CMJ, as indicated from the lack of significant interactions for group (condition x group, time x group or condition x time x group). In the short warm-up protocol, ROM was not affected by stretching, while in the long warm-up protocol ROM increased by 5.9% ± 0.7% (p = 0.001) after stretching. Similarly, CMJ remained unchanged after the short warm-up protocol, but increased by 4.6 ± 0.9% (p = 0.012) 4 min after the long warm- up protocol, despite the increased ROM. It is concluded that the initial levels of flexibility and CMJ performance do not alter the responses of elite gymnasts to warm-up protocols differing in stretching and potentiating exercise volumes. Furthermore, 3 sets of 5 tuck jumps result in a relatively large increase in CMJ performance despite an increase in flexibility in these highly-trained athletes. Key Points The initial levels of flexibility and vertical jump ability have no effect on straight leg raise range of motion (ROM) and counter-movement jump performance (CMJ) of elite gymnasts following warm-up protocols differing in stretching and potentiating exercise volumes Stretching of the main leg muscle groups for only 15 s has no effect on ROM of elite gymnasts In these highly-trained athletes, one set of 5 tuck jumps during warm-up is not adequate to increase CMJ performance, while 3 sets of 5 tuck jumps result in a relatively large increase in CMJ performance (by 4.6% above baseline), despite a 5.9% increase in flexibility due to the 30 s stretching exercises PMID:24570613

  16. [ROM and the position of the health insurance companies].

    PubMed

    Laane, R; Luijk, R

    2012-01-01

    Up till 2008 the Dutch mental health services came under the Dutch General Law on Special Medical Costs (AWBZ). Health insurers regarded the mental health services as 'black box'. In 2008 the mental health services were transferred to the basic health insurance system and the health insurers became responsible for the healthcare purchasing services. In the same year the mental health services began to use ROM to measure the effects of treatment and thereby improve the quality of treatment. To clarify the use that the insurers make of ROM. The developments in this field are described. The feedback supplied by ROM enables therapists to improve treatment. An additional benefit is that the mental health services are then in a position to improve quality at aggregate level and compare their own results with those of others. Nationally, ROM can provide health insurers with information about treatment quality in combination with the Consumer Quality Index (CQI), and national 'benchmarks' can be implemented. To facilitate the interpretation of these rom data the health insurers set up the independent foundation, Stichting Benchmark GGZ (mental health care), in which GGZ Nederland has participated since 2010. ROM provides therapists with a means for improving treatment and provides insurers with a means by which they can express their views about the quality of the mental health services at aggregate level.

  17. Balance and ankle range of motion in community-dwelling women aged 64 to 87 years: a correlational study.

    PubMed

    Mecagni, C; Smith, J P; Roberts, K E; O'Sullivan, S B

    2000-10-01

    This study investigated the relationship between balance measures and ankle range of motion (ROM) in community-dwelling elderly women with no health problems. Identification of modifiable factors associated with balance may enable clinicians to design treatments to help reduce the risk of falls in elderly people. The sample consisted of 34 women between the ages of 64 and 87 years (mean=74.7, SD=6.0). Goniometry was used to determine bilateral ankle active-assistive range of motion (AAROM) and passive range of motion. Balance capabilities were measured with the Functional Reach Test (FRT) and the Tinetti Performance-Oriented Mobility Assessment (POMA). Balance data for the FRT, POMA balance subtest, POMA gait subtest, and POMA total score were correlated with ankle ROM using the Pearson product moment correlation coefficient (PCC). Correlations between ROM and balance scores were found, ranging from.29 to.63. The POMA gait subtest and FRT resulted in higher correlations with ROM than did the POMA balance subtest (left total AAROM PCC=.63,.51, and.31). Correlations using composite ankle ROM scores were higher than individual motions. The strongest correlation existed between bilateral, total ankle AAROM and the POMA gait subtest scores (PCC=. 63) Correlations exist between ankle ROM and balance in community-dwelling elderly women. Additional research is needed to determine whether treatment directed at increasing ankle ROM can improve balance.

  18. Extension and flexion in the upper cervical spine in neck pain patients.

    PubMed

    Ernst, Markus J; Crawford, Rebecca J; Schelldorfer, Sarah; Rausch-Osthoff, Anne-Kathrin; Barbero, Marco; Kool, Jan; Bauer, Christoph M

    2015-08-01

    Neck pain is a common problem in the general population with high risk of ongoing complaints or relapses. Range of motion (ROM) assessment is scientifically established in the clinical process of diagnosis, prognosis and outcome evaluation in neck pain. Anatomically, the cervical spine (CS) has been considered in two regions, the upper and lower CS. Disorders like cervicogenic headache have been clinically associated with dysfunctions of the upper CS (UCS), yet ROM tests and measurements are typically conducted on the whole CS. A cross-sectional study assessing 19 subjects with non-specific neck pain was undertaken to examine UCS extension-flexion ROM in relation to self-reported disability and pain (via the Neck Disability Index (NDI)). Two measurement devices (goniometer and electromagnetic tracking) were employed and compared. Correlations between ROM and the NDI were stronger for the UCS compared to the CS, with the strongest correlation between UCS flexion and the NDI-headache (r = -0.62). Correlations between UCS and CS ROM were fair to moderate, with the strongest correlation between UCS flexion and CS extension ROM (r = -0.49). UCS flexion restriction is related to headache frequency and intensity. Consistency and agreement between both measurement systems and for all tests was high. The results demonstrate that separate UCS ROM assessments for extension and flexion are useful in patients with neck pain. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Evaluation of a minimally invasive procedure for sacroiliac joint fusion – an in vitro biomechanical analysis of initial and cycled properties

    PubMed Central

    Lindsey, Derek P; Perez-Orribo, Luis; Rodriguez-Martinez, Nestor; Reyes, Phillip M; Newcomb, Anna; Cable, Alexandria; Hickam, Grace; Yerby, Scott A; Crawford, Neil R

    2014-01-01

    Introduction Sacroiliac (SI) joint pain has become a recognized factor in low back pain. The purpose of this study was to investigate the effect of a minimally invasive surgical SI joint fusion procedure on the in vitro biomechanics of the SI joint before and after cyclic loading. Methods Seven cadaveric specimens were tested under the following conditions: intact, posterior ligaments (PL) and pubic symphysis (PS) cut, treated (three implants placed), and after 5,000 cycles of flexion–extension. The range of motion (ROM) in flexion–extension, lateral bending, and axial rotation was determined with an applied 7.5 N · m moment using an optoelectronic system. Results for each ROM were compared using a repeated measures analysis of variance (ANOVA) with a Holm–Šidák post-hoc test. Results Placement of three fusion devices decreased the flexion–extension ROM. Lateral bending and axial rotation were not significantly altered. All PL/PS cut and post-cyclic ROMs were larger than in the intact condition. The 5,000 cycles of flexion–extension did not lead to a significant increase in any ROMs. Discussion In the current model, placement of three 7.0 mm iFuse Implants significantly decreased the flexion–extension ROM. Joint ROM was not increased by 5,000 flexion–extension cycles. PMID:24868175

  20. A potential biomarker for fatigue: Oxidative stress and anti-oxidative activity.

    PubMed

    Fukuda, Sanae; Nojima, Junzo; Motoki, Yukari; Yamaguti, Kouzi; Nakatomi, Yasuhito; Okawa, Naoko; Fujiwara, Kazumi; Watanabe, Yasuyoshi; Kuratsune, Hirohiko

    2016-07-01

    We sought to determine whether oxidative stress and anti-oxidative activity could act as biomarkers that discriminate patients with chronic fatigue syndrome (CFS) from healthy volunteers at acute and sub-acute fatigue and resting conditions. We calculated the oxidative stress index (OSI) from reactive oxygen metabolites-derived compounds (d-ROMs) and the biological antioxidant potential (BAP). We determined changes in d-ROMs, BAP, and OSI in acute and sub-acute fatigue in two healthy groups, and compared their values at rest between patients with CFS (diagnosed by Fukuda 1994 criteria) and another group of healthy controls. Following acute fatigue in healthy controls, d-ROMs and OSI increased, and BAP decreased. Although d-ROMs and OSI were significantly higher after sub-acute fatigue, BAP did not decrease. Resting condition yielded higher d-ROMs, higher OSI, and lower BAP in patients with CFS than in healthy volunteers, but lower d-ROMs and OSI when compared with sub-acute controls. BAP values did not significantly differ between patients with CFS and controls in the sub-acute condition. However, values were significantly higher than in the resting condition for controls. Thus, measured of oxidative stress (d-ROMS) and anti-oxidative activity (BAP) might be useful for discriminating acute, sub-acute, and resting fatigue in healthy people from patients with CFS, or for evaluating fatigue levels in healthy people. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. PubMed Central

    Nozaki, S.; Kawai, M.; Shimoyama, R.; Futamura, N.; Matsumura, T.; Adachi, K.; Kikuchi, Y.

    2010-01-01

    The purpose of this study is to evaluate whether the range of motion exercise of the temporo-mandibular joint (jaw ROM exercise) with a hot pack and massage of the masseter muscle improve biting disorder in Duchenne muscular dystrophy (DMD). The subjects were 18 DMD patients (21.3 ± 4.1 years old). The jaw ROM exercise consisted of therapist-assisted training (2 times a week) and self-training (before each meal every day). The therapist-assisted training consisted of the application of a hot pack on the cheek of the masseter muscle region (15 minutes), the massage of the masseter (10 minutes), and jaw ROM exercise (5 minutes). The self-training involved jaw ROM exercise by opening the mouth to the maximum degree, ten times. These trainings continued for six months. Outcomes were evaluated by measuring the greatest occlusal force and the distance at the maximum degree of mouth opening between an incisor of the top and that of the bottom. Six months later, the greatest occlusal force had increased significantly compared with that at the start of jaw ROM exercise (intermediate values: from 73.8N to 97.3N) (p = 0.005) as determined by the Friedman test and Scheffé's nonparametric test. The patients' satisfaction with meals increased. However, the maximum degree of mouth opening did not change after six months of jaw ROM exercise. Jaw ROM exercise in DMD is effective for increasing the greatest occlusal force. PMID:21574523

  2. Qanimarisaj Qano'jib'alil--Engrandezcamos Nuestro Pensamiento (Let's Broaden Our Thinking). [CD-ROM].

    ERIC Educational Resources Information Center

    Academy for Educational Development, Washington, DC.

    This CD-ROM is part of an interactive and dynamic multimedia package of information and games for learning K'iche' and Ixil. The CD-ROMs help bilingual pre-service teachers improve their reading, writing, and listening comprehension skills in their own Mayan language. After a musical and colorful introduction, users may choose introductions to…

  3. How to Select CD-ROM Storybooks for Young Children: The Teacher's Role

    ERIC Educational Resources Information Center

    Shamir, Adina; Korat, Ofra

    2006-01-01

    This article addresses some key criteria for educators as they choose CD-ROM storybooks for young children's literacy development. The article includes: (1) A review of the pertinent literature on the quality and appropriateness of CD-ROM storybooks for literacy development; (2) An evaluation questionnaire to guide teachers in selecting CD-ROM…

  4. Correspondence between Video CD-ROM and Community-Based Job Preferences for Individuals with Developmental Disabilities

    ERIC Educational Resources Information Center

    Ellerd, David A.; Morgan, Robert L.; Salzberg, Charles L.

    2006-01-01

    This study examined correspondence in selections of job preference across a video CD-ROM assessment program, community jobs observed during employment site visits, and photographs of employment sites. For 20 participants ages 18 - 22 with developmental disabilities, the video CD-ROM program was initially administered to identify preferred jobs,…

  5. Putting a Medical Library Online: Phase III--Remote Access to CD-ROMs.

    ERIC Educational Resources Information Center

    Kittle, Paul

    1989-01-01

    Describes the implementation of a project that provides dial-up access to MEDLINE on remote optical data disk (CD-ROM) using software that enables callers to use programs like Wordstar, Lotus, and dBase. Highlights include networking CD-ROM databases, hardware considerations, advantages and disadvantages of remote access, and future plans. A…

  6. Reta'maxik Qatzij--Conociendo Nuestro Idioma (Knowing Our Language). [CD-ROM].

    ERIC Educational Resources Information Center

    Academy for Educational Development, Washington, DC.

    This CD-ROM is part of an interactive and dynamic multimedia package of information and games for learning K'iche' and Ixil. This CD-ROM includes six books in electronic format with interactive exercises that support improved bilingual and intercultural education and teacher training, specifically in the languages of K'iche' and Ixil. Books…

  7. Providing Access to CD-ROM Databases in a Campus Setting. Part II: Networking CD-ROMs via a LAN.

    ERIC Educational Resources Information Center

    Koren, Judy

    1992-01-01

    The second part of a report on CD-ROM networking in libraries describes LAN (local area network) technology; networking software and towers; gateway software for connecting to campuswide networks; Macintosh LANs; and network licenses. Several product and software reviews are included, and a sidebar lists vendor addresses. (NRP)

  8. Art of the Pacific Islands. [CD-ROM].

    ERIC Educational Resources Information Center

    Pacific Resources for Education and Learning, Honolulu, HI.

    Oceanic art has long been recognized for its quality and its influence on Western art. This CD-ROM presents over 100 of the finest examples of art from the Pacific region in the form of museum photos, contemporary video segments, and music. The CD-ROM includes such artifacts as masks and carvings from Melanesia, canoes and storyboards from…

  9. Captured Wisdom[TM]: Integrating Technology into Adult Literacy Instruction. [Booklet and CD-ROM Transcripts].

    ERIC Educational Resources Information Center

    North Central Regional Educational Lab., Oak Brook, IL. North Central Regional Tech. in Education Consortium.

    This document consists of a booklet describing the Captured Wisdom project and transcripts of videos from the two CD-ROM disks. The booklet details how to get the most from the CD-ROMs with suggestions directed toward teachers, professional development providers, and administrators. Six Captured Wisdom learning sites are listed. The Captured…

  10. CD-ROM Technology: A Manual for Librarians and Educators.

    ERIC Educational Resources Information Center

    Mambretti, Catherine

    The maturity of CD-ROM technology now shows a dramatic change in the way librarians and teachers do their jobs. Among their biggest challenges are deciding on equipment requirements and managing the disk collection. This manual is a step-by-step guide to making the most of CD-ROM technology in schools and libraries--from the acquisition of…

  11. Is there a difference in range of motion, neck pain, and outcomes in patients with ossification of posterior longitudinal ligament versus those with cervical spondylosis, treated with plated laminoplasty?

    PubMed

    Fujimori, Takahito; Le, Hai; Ziewacz, John E; Chou, Dean; Mummaneni, Praveen V

    2013-07-01

    There are little data on the effects of plated, or plate-only, open-door laminoplasty on cervical range of motion (ROM), neck pain, and clinical outcomes. The purpose of this study was to compare ROM after a plated laminoplasty in patients with ossification of posterior longitudinal ligament (OPLL) versus those with cervical spondylotic myelopathy (CSM) and to correlate ROM with postoperative neck pain and neurological outcomes. The authors retrospectively compared patients with a diagnosis of cervical stenosis due to either OPLL or CSM who had been treated with plated laminoplasty in the period from 2007 to 2012 at the University of California, San Francisco. Clinical outcomes were measured using the modified Japanese Orthopaedic Association (mJOA) scale and neck visual analog scale (VAS). Radiographic outcomes included assessment of changes in the C2-7 Cobb angle at flexion and extension, ROM at C2-7, and ROM of proximal and distal segments adjacent to the plated lamina. Sixty patients (40 men and 20 women) with an average age of 63.1 ± 10.9 years were included in the study. Forty-one patients had degenerative CSM and 19 patients had OPLL. The mean follow-up period was 20.9 ± 13.1 months. The mean mJOA score significantly improved in both the CSM and the OPLL groups (12.8 to 14.5, p < 0.01; and 13.2 to 14.2, respectively; p = 0.04). In the CSM group, the mean VAS neck score significantly improved from 4.2 to 2.6 after surgery (p = 0.01), but this improvement did not reach the minimum clinically important difference (MCID). Neither was there significant improvement in the VAS neck score in the OPLL group (3.6 to 3.1, p = 0.17). In the CSM group, ROM at C2-7 significantly decreased from 32.7° before surgery to 24.4° after surgery (p < 0.01). In the OPLL group, ROM at C2-7 significantly decreased from 34.4° to 20.8° (p < 0.01). In the CSM group, the change in the VAS neck score significantly correlated with the change in the flexion angle (r = - 0.31) and the extension angle (r = - 0.37); however, it did not correlate with the change in ROM at C2-7 (r = - 0.1). In the OPLL group, the change in the VAS neck score did not correlate with the change in the flexion angle (r = 0.03), the extension angle (r = - 0.17), or the ROM at C2-7 (r = - 0.28). The OPLL group had a significantly greater loss of ROM after surgery than did the CSM group (p = 0.04). There was no significant correlation between the change in ROM and the mJOA score in either group. Plated laminoplasty in patients with either OPLL or CSM decreases cervical ROM, especially in the extension angle. Among patients who have undergone laminoplasty, those with OPLL lose more ROM than do those with CSM. No correlation was observed between neck pain and ROM in either group. Neither group had a change in neck pain that reached the MCID following laminoplasty. Both groups improved in neurological function and outcomes.

  12. Reliability, Concurrent Validity, and Minimal Detectable Change for iPhone Goniometer App in Assessing Knee Range of Motion.

    PubMed

    Mehta, Saurabh P; Barker, Katherine; Bowman, Brett; Galloway, Heather; Oliashirazi, Nicole; Oliashirazi, Ali

    2017-07-01

    Much of the published works assessing the reliability of smartphone goniometer apps (SG) have poor generalizability since the reliability was assessed in healthy subjects. No research has established the values for standard error of measurement (SEM) or minimal detectable change (MDC) which have greater clinical utility to contextualize the range of motion (ROM) assessed using the SG. This research examined the test-retest reproducibility, concurrent validity, SEM, and MDC values for the iPhone goniometer app (i-Goni; June Software Inc., v.1.1, San Francisco, CA) in assessing knee ROM in patients with knee osteoarthritis or those after total knee replacement. A total of 60 participants underwent data collection which included the assessment of active knee ROM using the i-Goni and the universal goniometer (UG; EZ Read Jamar Goniometer, Patterson Medical, Warrenville, IL), knee muscle strength, and assessment of pain and lower extremity disability using quadruple numeric pain rating scale (Q-NPRS) and lower extremity functional scale (LEFS), respectively. Intraclass correlation coefficients (ICCs) were calculated to assess the reproducibility of the knee ROM assessed using the i-Goni and UG. Bland and Altman technique examined the agreement between these knee ROM. The SEM and MDC values were calculated for i-Goni assessed knee ROM to characterize the error in a single score and the index of true change, respectively. Pearson correlation coefficient examined concurrent relationships between the i-Goni and other measures. The ICC values for the knee flexion/extension ROM were superior for i-Goni (0.97/0.94) compared with the UG (0.95/0.87). The SEM values were smaller for i-Goni assessed knee flexion/extension (2.72/1.18 degrees) compared with UG assessed knee flexion/extension (3.41/1.62 degrees). Similarly, the MDC values were smaller for both these ROM for the i-Goni (6.3 and 2.72 degrees) suggesting smaller change required to infer true change in knee ROM. The i-Goni assessed knee ROM showed expected concurrent relationships with UG, knee muscle strength, Q-NPRS, and the LEFS. In conclusion, the i-Goni demonstrated superior reproducibility with smaller measurement error compared with UG in assessing knee ROM in the recruited cohort. Future research can expand the inquiry for assessing the reliability of the i-Goni to other joints. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  13. A repeated-measures analysis of the effects of soft tissues on wrist range of motion in the extant phylogenetic bracket of dinosaurs: Implications for the functional origins of an automatic wrist folding mechanism in Crocodilia.

    PubMed

    Hutson, Joel David; Hutson, Kelda Nadine

    2014-07-01

    A recent study hypothesized that avian-like wrist folding in quadrupedal dinosaurs could have aided their distinctive style of locomotion with semi-pronated and therefore medially facing palms. However, soft tissues that automatically guide avian wrist folding rarely fossilize, and automatic wrist folding of unknown function in extant crocodilians has not been used to test this hypothesis. Therefore, an investigation of the relative contributions of soft tissues to wrist range of motion (ROM) in the extant phylogenetic bracket of dinosaurs, and the quadrupedal function of crocodilian wrist folding, could inform these questions. Here, we repeatedly measured wrist ROM in degrees through fully fleshed, skinned, minus muscles/tendons, minus ligaments, and skeletonized stages in the American alligator Alligator mississippiensis and the ostrich Struthio camelus. The effects of dissection treatment and observer were statistically significant for alligator wrist folding and ostrich wrist flexion, but not ostrich wrist folding. Final skeletonized wrist folding ROM was higher than (ostrich) or equivalent to (alligator) initial fully fleshed ROM, while final ROM was lower than initial ROM for ostrich wrist flexion. These findings suggest that, unlike the hinge/ball and socket-type elbow and shoulder joints in these archosaurs, ROM within gliding/planar diarthrotic joints is more restricted to the extent of articular surfaces. The alligator data indicate that the crocodilian wrist mechanism functions to automatically lock their semi-pronated palms into a rigid column, which supports the hypothesis that this palmar orientation necessitated soft tissue stiffening mechanisms in certain dinosaurs, although ROM-restricted articulations argue against the presence of an extensive automatic mechanism. Anat Rec, 297:1228-1249, 2014. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

  14. Comparison of high, medium and low mobilization forces for increasing range of motion in patients with hip osteoarthritis: A randomized controlled trial.

    PubMed

    Estébanez-de-Miguel, Elena; Fortún-Agud, María; Jimenez-Del-Barrio, Sandra; Caudevilla-Polo, Santos; Bueno-Gracia, Elena; Tricás-Moreno, José Miguel

    2018-05-29

    Manual therapy has been shown to increase range of motion (ROM) in hip osteoarthritis (OA). However, the optimal intensity of force during joint mobilization is not known. To compare the effectiveness of high, medium and low mobilization forces for increasing range of motion (ROM) in patients with hip OA and to analyze the effect size of the mobilization. Randomized controlled trial. Sixty patients with unilateral hip OA were randomized to three groups: low, medium or high force mobilization group. Participants received three treatment sessions of long-axis distraction mobilization (LADM) in open packed position and distraction forces were measured at each treatment. Primary outcomes: passive hip ROM assessed before and after each session. pain recorded with Western Ontario and McMaster Universities (WOMAC) pain subscale before and after the three treatment sessions. Hip ROM increased significantly (p < 0.05) in the high-force mobilization group (flexion: 10.6°, extension: 8.0°, abduction:6.4°, adduction: 3.3°, external rotation: 5.6°, internal rotation: 7.6°). These improvements in hip ROM were statistically significant (p < 0.05) compared to the low-force group. There were no significant changes in the low-force and medium-force groups for hip ROM. No significant differences in hip pain were found between treatment groups. A high force LADM in open packed position significantly increased hip ROM in all planes of motion compared to a medium or low force mobilization in patients with hip OA. A specific intensity of force mobilization appears to be necessary for increasing ROM in hip OA. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Muscle strength and knee range of motion after femoral lengthening.

    PubMed

    Bhave, Anil; Shabtai, Lior; Woelber, Erik; Apelyan, Arman; Paley, Dror; Herzenberg, John E

    2017-04-01

    Background and purpose - Femoral lengthening may result in decrease in knee range of motion (ROM) and quadriceps and hamstring muscle weakness. We evaluated preoperative and postoperative knee ROM, hamstring muscle strength, and quadriceps muscle strength in a diverse group of patients undergoing femoral lengthening. We hypothesized that lengthening would not result in a significant change in knee ROM or muscle strength. Patients and methods - This prospective study of 48 patients (mean age 27 (9-60) years) compared ROM and muscle strength before and after femoral lengthening. Patient age, amount of lengthening, percent lengthening, level of osteotomy, fixation time, and method of lengthening were also evaluated regarding knee ROM and strength. The average length of follow-up was 2.9 (2.0-4.7) years. Results - Mean amount of lengthening was 5.2 (2.4-11.0) cm. The difference between preoperative and final knee flexion ROM was 2° for the overall group. Congenital shortening cases lost an average of 5% or 6° of terminal knee flexion, developmental cases lost an average of 3% or 4°, and posttraumatic cases regained all motion. The difference in quadriceps strength at 45° preoperatively and after lengthening was not statistically or clinically significant (2.7 Nm; p = 0.06). Age, amount of lengthening, percent lengthening, osteotomy level, fixation time, and lengthening method had no statistically significant influence on knee ROM or quadriceps strength at final follow-up. Interpretation - Most variables had no effect on ROM or strength, and higher age did not appear to be a limiting factor for femoral lengthening. Patients with congenital causes were most affected in terms of knee flexion.

  16. Resumption of menses in anorexia nervosa during a course of family-based treatment

    PubMed Central

    2013-01-01

    Background The resumption of menses (ROM) is considered an important clinical marker in weight restoration for patients with anorexia nervosa (AN). The purpose of this study was to examine ROM in relation to expected body weight (EBW) and psychosocial markers in adolescents with AN. Methods We conducted a retrospective chart review at The University of Chicago Eating Disorders Program from September 2001 to September 2011 (N = 225 females with AN). Eighty-four adolescents (Mean age = 15.1, SD = 2.2) with a DSM-IV diagnosis of AN, presenting with secondary amenorrhea were identified. All participants had received a course of outpatient family-based treatment (FBT), i.e., ~20 sessions over 12 months. Weight and menstrual status were tracked at each therapy session throughout treatment. The primary outcome measures were weight (percent of expected for sex, age and height), and ROM. Results Mean percent EBW at baseline was 82.0 (SD = 6.5). ROM was reported by 67.9% of participants (57/84), on average at 94.9 (SD = 9.3) percent EBW, and after having completed an average of 13.5 (SD = 10.7) FBT sessions (~70% of standard FBT). Compared to participants without ROM by treatment completion, those with ROM had significantly higher baseline Eating Disorder Examination Global scores (p = .004) as well as Shape Concern (p < .008) and Restraint (p < .002) subscale scores. No other differences were found. Conclusions Results suggest that ROM occur at weights close to the reference norms for percent EBW, and that high pre-treatment eating disorder psychopathology is associated with ROM. Future research will be important to better understand these differences and their implications for the treatment of adolescents with AN. PMID:24926411

  17. Responsiveness to Change of Functional Limitation Reporting: Cross-sectional Study Using the Intermountain ROMS Scale in Outpatient Rehabilitation.

    PubMed

    Brennan, Gerard P; Hunter, Stephen J; Snow, Greg; Minick, Kate I

    2017-12-01

    The Centers for Medicare and Medicaid Services (CMS) require physical therapists document patients' functional limitations. The process is not standardized. 
A systematic approach to determine a patient's functional limitations and responsiveness to change is needed. The purpose of this study is to compare patient-reported outcomes (PROs) responsiveness to change using 7-level severity/complexity modifier scale proposed by Medicare to a derived scale implemented by Intermountain Healthcare's Rehabilitation Outcomes Management System (ROMS). This was a retrospective, observational cohort design. 165,183 PROs prior to July 1, 2013, were compared to 46,334 records from July 1, 2013, to December 31, 2015. Histograms and ribbon plots illustrate distribution and change of patients' scores. ROMS raw score ranges were calculated and compared to CMS' severity/complexity levels based on score percentage. Distribution of the population was compared based on the 2 methods. Sensitivity and specificity were compared for responsiveness to change based on minimal clinically important difference (MCID). Histograms demonstrated few patient scores placed in CMS scale levels at the extremes, whereas the majority of scores placed in 2 middle levels (CJ, CK). ROMS distributed scores more evenly across levels. Ribbon plots illustrated advantage of ROMS' using narrower score ranges. Greater chance for patients to change levels was observed with ROMS when an MCID was achieved. ROMS narrower scale levels resulted in greater sensitivity and good specificity. Geographic representation for the United States was limited. Without patients' global rating of change, a reference standard to gauge validation of improvement could not be provided. ROMS provides a standard approach to identify accurately functional limitation modifier levels and to detect improvement more accurately than a straight across transposition using the CMS scale. © 2017 American Physical Therapy Association

  18. The correlation between serum amyloid A and reactive oxygen metabolites in a young Mongolian population.

    PubMed

    Kotani, Kazuhiko; Yamada, Toshiyuki; Uurtuya, Shuumarjav; Taniguchi, Nobuyuki

    2012-01-01

    Chronic inflammation and oxidative stress are associated with lifestyle-related diseases. Research into the pathophysiology of lifestyle-related diseases is important for Mongolian people. Our study investigated the correlation among the d-ROMs test (a measure of the total oxidant capacity of blood), serum amyloid A (SAA) and high-sensitivity C-reactive protein (hs-CRP) levels in a young Mongolian population. The data, including anthropometric and biochemical markers, were collected from 78 Mongolian volunteers (male/female = 27/ 51, mean age 21 years). The correlation between the SAA and d-ROMs levels was examined, as well as the correlation between the hs-CRP and d-ROMs levels. The SAA levels were 3.2 microg/mL (median), hs-CRP .04 mg/dL (median) and d-ROMs 309 CARR U, respectively. There was a significant and positive correlation between the SAA and d-ROMs levels (r=.40, P<.01), in addition to a significant and positive correlation between the hs-CRP and d-ROMs levels (r = .32, P < .01). These significant correlations remained independent in a multiple linear regression analysis. A subgroup analysis by sex revealed the positive correlation between the SAA and d-ROMs levels to be greater, relative to that between the hs-CRP and d-ROMs levels, particularly in the female group. The coexistence of chronic inflammation and oxidative stress can be present even in young Mongolian people, suggesting that their coexistence may be a target of early prevention of lifestyle-related diseases. In addition, not only hs-CRP, but also SAA can be used to evaluate the relationship of oxidative stress in this population. Further studies are necessary to confirm the observed relationship.

  19. [Analyses of segment motor function in patients with degenerative lumbar disease on the treatment of WavefleX dynamic stabilization system].

    PubMed

    Wu, Junsong; Du, Junhua; Jiang, Xiangyun; Wang, Quan; Li, Xigong; Du, Jingyu; Lin, Xiangjin

    2014-06-17

    To explore the changes of range-of-motion (ROM) in patients with degenerative lumbar disease on the treatment of WavefleX dynamic stabilization system and examine the postoperative lumbar regularity and tendency of ROM. Nine patients with degenerative lumbar disease on the treatment of WavefleX dynamic stabilization system were followed up with respect to ROMs at 5 timepoints within 12 months. Records of ROM were made for instrumented segments, adjacent segments and total lumbar. Compared with preoperation, ROMs in non-fusional segments with WavefleX dynamic stabilization system decreased statistical significantly (P < 0.05 or P < 0.01) at different timepoints; ROMs in adjacent segments increased at some levels without wide statistical significance. The exception was single L3/4 at Month 12 (P < 0.05) versus control group simultaneously at the levels of L3/4, L4/5 and L5/S1, ROMs decreased at Months 6 and 12 with wide statistical significance (P < 0.05 or P < 0.01). ROMs in total lumbar had statistical significant decrease (P < 0.01) in both group of non-fusional segments and hybrid group of non-fusion and fusion. The trends of continuous augments were observed during follow-ups. Statistically significant augments were also acquired at 4 timepoints as compared to control group (P < 0.01). The treatment of degenerative lumbar diseases with WavefleX dynamic stabilization system may limit excessive extension/inflexion and preserve some motor functions. Moreover, it can sustain physiological lordosis, decrease and transfer disc load in adjacent segments to prevent early degeneration of adjacent segment. Trends of motor function augment in total lumbar need to be confirmed during future long-term follow-ups.

  20. Creating a CD-ROM program for cancer-related patient education.

    PubMed

    Agre, Patricia; Dougherty, James; Pirone, Jane

    2002-04-01

    To describe the process of developing a cancer-related patient and family education CD-ROM program and initial evaluation results. Published research, theory, practice, and personal experience. CD-ROM programs can be far more comprehensive than the booklets and videotapes used more commonly in patient education. Developing CD-ROM programs requires funding, organizational skills, access to content experts, and a team composed of people who have the varied skills required for a finished multimedia product. The time frame for CD-ROM production is often longer than that of other patient-education formats. Published reports and this institution's experience confirm that patients accept this medium. Evaluation to date suggests that CD-ROMs may be more useful to patients and their families than any other single information source. CD-ROM technology is more expensive than videotapes and booklets, but it allows for greater depth of content and may satisfy a broader range of educational needs than other media. Funding often can be obtained through foundations and with unrestricted educational grants from pharmaceutical companies. Nurses can lead multidisciplinary teams to produce CD-ROMs for their patient populations. These programs can be used before a patient has a first consultation to introduce a cancer or treatment and anytime during cancer diagnosis and treatment. They can reinforce one-on-one teaching or provide greater depth of content than ever could be provided in individualized teaching sessions. They can facilitate patients' self-directed learning and may allow nurses and doctors to teach on a different level. These programs also can complement patients' Internet searches either by creating a solid foundation for further investigation or by confirming the reliability of information gained through a variety of Internet sources.

  1. Early return to baseline range of motion and strength after anterior shoulder instability surgery: a Multicenter Orthopaedic Outcomes Network (MOON) shoulder group cohort study.

    PubMed

    Buckwalter V, Joseph A; Wolf, Brian R; Glass, Natalie; Bollier, Matt; Kuhn, John E; Hettrich, Carolyn M

    2018-03-23

    Patients often return to higher-level activities and sports at 4 to 8 months after anterior shoulder stabilization procedures. It is unknown what percentage of patients have regained normal function at this time frame and what factors predict residual deficits, range of motion (ROM), and strength after anterior shoulder instability surgery. Ten participating sites throughout the United States enrolled patients in a prospective cohort study including primary, revision, arthroscopic, and open anterior stabilization procedures. Baseline demographic data and patient outcomes questionnaires were collected with initial physical examination, treatment, surgical findings, and surgical repair details. At the 6-month follow-up visit, ROM and strength measurements were collected and compared with preoperative measurements. There were 348 patients identified who underwent surgical treatment for anterior shoulder instability. Of these, 259 patients (74.0%) returned to baseline, and 89 (26.0%) did not return to baseline shoulder ROM (≥20° loss of ROM) or strength. A higher Beighton score (P = .01) and number of dislocations (P < .01) were associated with failure to regain baseline ROM and strength at early follow-up. No surgical variables were found to influence return to baseline function, including open vs. arthroscopic surgery, primary vs. revision surgery, and number of suture anchors. By 4 to 8 months postoperatively, 76% of patients return to baseline ROM, 98% return to baseline strength, and 74% return to both baseline ROM and strength. An increased number of dislocations and generalized joint laxity were associated with failure to return to baseline ROM and strength at early follow-up after anterior shoulder instability surgery. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  2. Student assessment of the educational benefits of using a CD-ROM for instruction of basic surgical skills.

    PubMed

    Howe, Lisa M; Boothe, Harry W; Hartsfield, Sandee M

    2005-01-01

    At Texas A&M University, introductory-level surgical lecture and laboratory notes were converted to a CD-ROM format that included illustrative photographs as well as instructional videos demonstrating the basic surgical skills that all students were required to master. The CD-ROM was distributed to all students in place of traditional paper notes in the second-year surgical class in the professional veterinary curriculum. The study reported here was designed to evaluate the educational benefits of the use of the CD-ROM in place of traditional paper notes by examining the attitudes and practices of students before and after exposure to the CD-ROM format. An anonymous survey was distributed to students in the second-year introductory surgery course on the first day of class and again on the last day of class. Responses to questions were tabulated, response frequencies determined, and Chi-square analysis performed to determine differences between initial and final responses. On the final survey, 89 per cent of students responded that the instructional videos definitely helped them prepare for the laboratory, and 77 per cent responded that they were more likely to practice techniques learned from the CD-ROM videos than those learned from traditional study materials. The majority of students believed that the CD-ROM improved both the course (60 per cent) and their learning experience (62 per cent) as compared to traditional paper notes. Including instructional videos on the CD-ROM enhanced the educational experience of the students by promoting preparedness for laboratories and promoting practice of techniques learned from the videos outside of the laboratory.

  3. Ankle Ranges of Motion During Extended Activity Periods While Taped and Braced

    PubMed Central

    Paris, David L.; Kokkaliaris, Jimmy; Vardaxis, Vassilios

    1995-01-01

    Tape has traditionally been used to support the ankle during activity. More recently, commercial ankle braces have been worn as an alternative. The cumulative information on the effects of taped versus braced ankle support or interbrace comparisons is inconclusive. With few exceptions, ankle brace studies have collected data soon after support conditions were administered. Plantar-dorsiflexion and inversion-eversion ranges of motion (ROM) of 30 subjects were compared under conditions of unsupported, nonelastic adhesivetaped, and Swede-O and Sub Talar Support-braced ankles. We recorded measurements before activity and after periods of 15, 30, 45, and 60 minutes of selected activity on a motorized treadmill. All support conditions significantly reduced preactivity ROM in all directions compared to unsupported ankles. Results showed that the ankle significantly increased in plantarflexion ROM 15 minutes after the initiation of activity with tape or the SubTalar Support-brace, and after 30 minutes with the Swede-O brace. Tape showed further significant increases in plantarflexion ROM after 15-minute intervals of 30, 45, and 60 minutes of activity. All three support conditions had increased significantly in inversion ROM by 15 minutes of activity. The SubTalar Support brace showed a further significant inversion ROM increase between 15 and 30 minutes postactivity. We conclude that the Swede-O and SubTalar Support braces and tape offer significant preactivity ankle support in all four directions of movement. We also conclude that both braces offer longer postactivity support than tape. In inversion ROM and plantarflexion ROM, actions prevalent in ankle sprains, the Swede-O brace retained support longer than the SubTalar Support brace. ImagesFig 1.Fig 2.Fig 3. PMID:16558340

  4. Monitoring patron use of CD-ROM databases using SignIn-Stat.

    PubMed Central

    Silver, H; Dennis, S

    1990-01-01

    SignIn-Stat, a PC-based, menu-driven program, collects information from users of the library's public access computer systems. It was used to collect patron use data for the library's four CD-ROM workstations for the period September 1987 to April 1988 and to survey users for the period December 1987 to March 1988. During the sample period, 5,909 CD-ROM uses were recorded. MEDLINE was the most heavily used database, followed by PsycLIT and Micromedex CCIS. Students accounted for 61% of the use, while faculty, residents, and staff were responsible for 31%. Graduate students had the highest rate of use per student. Nineteen percent of use was by patrons who had never used CD-ROMs before, while 37% was by patrons who had used CD-ROMs ten or more times. Residents were the least experienced user group, while graduate students and faculty were the most experienced. PMID:2203498

  5. Uwachib'alil Qach'ab'al--Asi se Ilustra mi Palabra (Illustrating My Words). [CD-ROM].

    ERIC Educational Resources Information Center

    Academy for Educational Development, Washington, DC.

    This CD-ROM is part of an interactive and dynamic multimedia package of information and games for learning K'iche' and Ixil. This CD-ROM contains a database of 3,000 culturally-relevant vocabulary words in K'iche', Ixil, and Spanish, with appropriate illustrations that describe traditional Mayan rituals, foods, beliefs, clothing, and other topics.…

  6. CD-ROM Troubleshooting Manual: Support for Reference Desk Librarians.

    ERIC Educational Resources Information Center

    Nipp, Deanna; Shamy, Salwa

    1992-01-01

    Discusses the impact of CD-ROM services on reference departments and describes the development of a troubleshooting manual for the Library of Science and Medicine at Rutgers University. The seven steps followed in writing the manual are presented, and it is noted that it has proved to be an effective support for reference and CD-ROM services. (21…

  7. The Boreal Virtual Forest. [CD-ROM].

    ERIC Educational Resources Information Center

    Indiana Univ.-Purdue Univ., Indianapolis.

    This CD-ROM is an educational CD-ROM aimed at classroom audiences in 5th grade and above. Using QuickTime Virtual Reality (QTVR), the Boreal Virtual Forest is designed so that students are able to see views from inside the central hardwood forest and look up or down or spin around 360 degrees. The program allows students to become familiar with…

  8. "Let's Talk about Sex": Pilot Study of an Interactive CD-ROM to Prevent HIV/STIS in Female Adolescents

    ERIC Educational Resources Information Center

    Ito, Kristin E.; Kalyanaraman, Sri; Ford, Carol A.; Brown, Jane D.; Miller, William C.

    2008-01-01

    The purpose of this study was to develop and pilot-test an interactive CD-ROM aimed at the prevention of sexually transmitted infections (STIs) in female adolescents. The CD-ROM includes prevention information, models skills for negotiating abstinence and consistent condom use, teaches media literacy, and allows the user to choose a culturally…

  9. Evaluation of Two CD-ROMs from a Series on Cell Biology

    ERIC Educational Resources Information Center

    Sander, Uwe; Kerlen, Gertraude; Steinke, Mattias; Huk, Thomas; Floto, Christian

    2003-01-01

    Two CD-ROMs from a series dealing with various major aspects of cell biology are evaluated in this paper using quantitative and qualitative approaches. The findings delimit similarities and differences of the two CD-ROMs and shed light on how the programs could be used in the learning process and how they should not be. The overall impression, as…

  10. Maintaining the Dialogue: Joint Involvement in a Stand-Alone CD-Rom Chinese Course.

    ERIC Educational Resources Information Center

    Orton, Jane

    2003-01-01

    Presents a stand-alone CD-Rom version of a Web-based course in Modern Standard Chinese and addresses the problem of losing opportunities for negotiation in joint involvement episodes with teachers and peers in the CD-ROM course. Demonstrates trials of a mode of self-assessment in tasks using annotated sample texts generated by other students. (VWL)

  11. 76 FR 60023 - Pesticide Products; Receipt of Applications To Register New Uses

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-28

    ... or CD-ROM you submit. If EPA cannot read your comment due to technical difficulties and cannot... part or all of the information that you claim to be CBI. For CBI information in a disk or CD-ROM that you mail to EPA, mark the outside of the disk or CD-ROM as CBI and then identify electronically within...

  12. Design and Implementation of a Multimedia CD-ROM-Based Directed Study Preservice Teacher Education Course.

    ERIC Educational Resources Information Center

    Morse, Timothy

    This paper discusses the development and implementation of a computer-based directed study preservice teacher education course. Specifically, it explains the procedures followed to create the ten multimedia CD-ROMs that comprise the course, and how preservice teachers use the CD-ROMs. Topics to be covered include (1) rationale for course creation;…

  13. Benefits and Pitfalls of Using HTML as a CD-ROM Development Tool.

    ERIC Educational Resources Information Center

    Misanchuk, Earl R.; Schwier, Richard A.

    The hypertext markup language (HTML) used to develop pages for the world wide web also has potential for use in creating some types of multimedia instruction destined for CD-ROMs. After providing a brief overview of HTML, this document presents pros and cons relevant to CD-ROM production. HTML can offer compatibility to both Windows and Macintosh…

  14. Networking CD-ROMs: The Decision Maker's Guide to Local Area Network Solutions.

    ERIC Educational Resources Information Center

    Elshami, Ahmed M.

    In an era when patrons want access to CD-ROM resources but few libraries can afford to buy multiple copies, CD-ROM local area networks (LANs) are emerging as a cost-effective way to provide shared access. To help librarians make informed decisions, this manual offers information on: (1) the basics of LANs, a "local area network primer";…

  15. Oyster Reef Communities in the Chesapeake Bay. Virginia Institute of Marine Science Educational Series. [CD-ROM].

    ERIC Educational Resources Information Center

    Harding, Juliana M.; Mann, Roger; Clark, Vicki P.

    This CD-ROM, Oyster Reef Communities in the Chesapeake Bay, describes oyster reefs, reef communities, and their roles in the Chesapeake Bay ecosystem. Detailed descriptions of scientific research methods and techniques used to monitor and describe oyster reef communities as well as applications of the resulting data are provided. The CD-ROM was…

  16. Assessment of Aerobic Endurance: A Comparison between CD-ROM and Laboratory-Based Instruction.

    ERIC Educational Resources Information Center

    Kirkwood, Margaret; Sharp, Bob; de Vito, Giuseppe; Nimmo, Myra A.

    2002-01-01

    Describes a CD-ROM version of a basic course in exercise physiology that was developed in the United Kingdom to overcome problems of staff time, expense, ethical considerations, and large student numbers. Compares it to a traditional course and concludes that adding more active learning approaches to the CD-ROM would enhance student learning. (LRW)

  17. SCUTREA Conference Proceedings, 1970-1997. 25th Anniversary CD-ROM.

    ERIC Educational Resources Information Center

    Standing Conference on Univ. Teaching and Research in the Education of Adults.

    This CD-ROM contains 693 papers on university teaching and research in the education of adults that were presented during the 27-year period from 1970 through 1997. The CD-ROM is designed to be used with the Macintosh, Windows 95, and Windows 3.1 operating systems and Adobe Acrobat Portable Document Format (version 3), which is included along with…

  18. A note on 'The main problem of satellite theory for small eccentricities, by A. Deprit and A. Rom, 1970.'

    NASA Technical Reports Server (NTRS)

    Aksnes, K.

    1971-01-01

    Criticism of Deprit and Rom's (1970) extension of Brouwer's (1959) first-order satellite theory to the third order in J sub 2. It is noted that Deprit and Rom's theory suffers from the drawback that the perturbations of all orders are expressed as infinite power series in the eccentricity e. It is demonstrated that Deprit and Rom's reported failure to extend Brouwer's theory to the second order in a closed form by means of Lie transforms is due to an oversight and is not caused by difficulties inherent in the problem or in the particular perturbation method used.

  19. Sex, shoulder pain, and range of motion in manual wheelchair users.

    PubMed

    Wessels, Karla K; Brown, Jennifer L; Ebersole, Kyle T; Sosnoff, Jacob J

    2013-01-01

    Upwards of 70% of manual wheelchair users (MWUs) experience shoulder pain. Pain is more prevalent among females than males. The causes of this sex discrepancy are not understood. Decreased range of motion (ROM) has been suggested as a major contributor, but the interaction of sex, ROM, and shoulder pain has not been investigated, thus the purpose of this investigation. We divided 30 MWUs (18 males, 12 females; 21.93 +/- 3.77 yr) into two groups based on self-reported shoulder pain: pain group (n = 14; 9 males, 5 females) and no pain group (n = 16; 9 males, 7 females). We used a digital goniometer to assess ROM. Participants' shoulder active and passive ROMs were tested bilaterally on the following joint motions: flexion, extension, abduction, adduction, internal rotation, and external rotation. We used a visual analog scale to assess shoulder pain. Of the participants, 47% reported shoulder pain. Overall, the no pain group had greater ROM than the pain group, with further analysis revealing this association was only significant in females during extension (p < 0.05). ROM impairments were only present in extension in females with shoulder pain. The mechanism underlying this sex difference is not clear.

  20. Wireless wearable range-of-motion sensor system for upper and lower extremity joints: a validation study.

    PubMed

    Kumar, Yogaprakash; Yen, Shih-Cheng; Tay, Arthur; Lee, Wangwei; Gao, Fan; Zhao, Ziyi; Li, Jingze; Hon, Benjamin; Tian-Ma Xu, Tim; Cheong, Angela; Koh, Karen; Ng, Yee-Sien; Chew, Effie; Koh, Gerald

    2015-02-01

    Range-of-motion (ROM) assessment is a critical assessment tool during the rehabilitation process. The conventional approach uses the goniometer which remains the most reliable instrument but it is usually time-consuming and subject to both intra- and inter-therapist measurement errors. An automated wireless wearable sensor system for the measurement of ROM has previously been developed by the current authors. Presented is the correlation and accuracy of the automated wireless wearable sensor system against a goniometer in measuring ROM in the major joints of upper (UEs) and lower extremities (LEs) in 19 healthy subjects and 20 newly disabled inpatients through intra (same) subject comparison of ROM assessments between the sensor system against goniometer measurements by physical therapists. In healthy subjects, ROM measurements using the new sensor system were highly correlated with goniometry, with 95% of differences < 20° and 10° for most movements in major joints of UE and LE, respectively. Among inpatients undergoing rehabilitation, ROM measurements using the new sensor system were also highly correlated with goniometry, with 95% of the differences being < 20° and 25° for most movements in the major joints of UE and LE, respectively.

  1. Vertical Mandibular Range of Motion in Anesthetized Dogs and Cats

    PubMed Central

    Gracis, Margherita; Zini, Eric

    2016-01-01

    The main movement of the temporomandibular joint of dogs and cats is in vertical dimensions (opening and closing the mouth). An objective evaluation of the vertical mandibular range of motion (vmROM) may favor early diagnosis of a number of conditions affecting the joint mobility. vmROM, corresponding to the maximum interincisal opening, was measured in 260 dogs and 127 cats anesthetized between June 2011 and April 2015 because of oral or maxillofacial problems and procedures. Animals with a known history of or having current diseases considered to hamper mandibular extension were excluded from the study. Dogs were divided into four subgroups, based on body weight: subgroup 1 (≤5.0 kg, 51 dogs), subgroup 2 (5.1–10.0 kg, 56 dogs), subgroup 3 (10.1–25 kg, 66 dogs), and subgroup 4 (>25.1 kg, 87 dogs). The mean vmROM of all dogs was 107 ± 30 mm (median 109, range 40–180); in subgroup 1 was 67 ± 15 mm (median 67, range 40–100), in subgroup 2 was 93 ± 15 mm (median 93, range 53–128), in subgroup 3 was 115 ± 19 mm (median 116, range 59–154), and in subgroup 4 was 134 ± 19 mm (median 135, range 93–180). The mean vmROM of the cats was 62 ± 8 mm (median 63, range 41–84). Correlations between vmROM, age, sex, and body weight were evaluated. In dogs, vmROM did not correlate with age, and in cats a weak positive correlation was found. vmROM and body weight were positively correlated in both populations, except dog subgroup 2. Overall, mean vmROM and body weight were significantly higher in male than in female, both in dogs and in cats. However, vmROM did not differ between sexes in any of the canine subgroups, and only in subgroup 4 male dogs were significantly heavier than females. Evaluation of vmROM should be incorporated into every diagnostic examination as it may be valuable in showing changes over time for every single patient. PMID:27446939

  2. Oswestry Disability Index is a better indicator of lumbar motion than the Visual Analogue Scale.

    PubMed

    Ruiz, Ferrin K; Bohl, Daniel D; Webb, Matthew L; Russo, Glenn S; Grauer, Jonathan N

    2014-09-01

    Lumbar pathology is often associated with axial pain or neurologic complaints. It is often presumed that such pain is associated with decreased lumbar motion; however, this correlation is not well established. The utility of various outcome measures that are used in both research and clinical practice have been studied, but the connection with range of motion (ROM) has not been well documented. The current study was performed to assess objectively the postulated correlation of lumbar complaints (based on standardized outcome measures) with extremes of lumbar ROM and functional ROM (fROM) with activities of daily living (ADLs) as assessed with an electrogoniometer. This study was a clinical cohort study. Subjects slated to undergo a lumbar intervention (injection, decompression, and/or fusion) were enrolled voluntarily in the study. The two outcome measures used in the study were the Visual Analogue Scale (VAS) for axial extremity, lower extremity, and combined axial and lower extremity, as well as the Oswestry Disability Index (ODI). Pain and disability scores were assessed with the VAS score and ODI. A previously validated electrogoniometer was used to measure ROM (extremes of motion in three planes) and fROM (functional motion during 15 simulated activities of daily living). Pain and disability scores were analyzed for statistically significant association with the motion assessments using linear regression analyses. Twenty-eight men and 39 women were enrolled, with an average age of 55.6 years (range, 18-79 years). The ODI and VAS were associated positively (p<.001). Combined axial and lower extremity VAS scores were associated with lateral and rotational ROM (p<.05), but not with flexion/extension or any fROM. Similar findings were noted for separately analyzed axial and lower extremity VAS scores. On the other hand, the ODI correlated inversely with ROM in all planes, and fROM in at least one plane for 10 of 15 ADLs (p<.05). Extremes of lumbar motion and motions associated with ADLs are of increasing clinical interest. Although the ODI and VAS are associated with each other, the ODI appears to be a better predictor of these motion parameters than the VAS (axial extremity, lower extremity, or combined) and may be more useful in the clinical setting when considering functional movement parameters. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Preliminary validation of the Review of Musculoskeletal System (ROMS) questionnaire.

    PubMed

    Bershadsky, Boris; Kane, Robert L; Wuerz, Thomas; Jones, Morgan; Brighton, Brian; Stitzlein, Russell; Parker, Richard; Iannotti, Joseph P

    2015-04-01

    Measurement of clinical outcomes is necessary to define best practice. It requires a validated tool that can be easily applied as part of clinical practice. We present the preliminary validation of a brief self-reported Review of Musculoskeletal System (ROMS) questionnaire that captures functional limitations due to musculoskeletal problems and other medical and emotional conditions. Data were derived from a clinical outcomes database (Orthopaedic Minimal Data Set [OrthoMiDaS]) that combines patient-reported data collected as part of routine care and secondary data extracted from electronic medical records. The study utilized 82,873 encounters collected from 24,116 consecutive patients with problems in the upper and lower extremities. In addition to the ROMS, the study used version 2 of the Short Form-12 (SF-12v2), the Penn Shoulder Score (PSS), the Hip disability and Osteoarthritis Outcome Score (HOOS), and the Knee injury and Osteoarthritis Outcome Score (KOOS) questionnaires. Fifteen cross-sectional samples were used to evaluate the floor and ceiling effects as well as the construct and content validity. Five longitudinal cohorts were used to measure test-retest reliability and responsiveness. Standard statistical tests were applied. The floor and ceiling effects of the ROMS questionnaire in patients with shoulder, hip, and knee problems ranged from 1.3% to 8.5%. Construct-validity tests confirmed convergent and divergent validity of the ROMS. The tests also justified its additional value when the ROMS was used with joint-specific tools. When measuring test-retest reliability of the ROMS scales, intraclass correlation ranged from 0.80 to 0.90 at approximately one week and from 0.71 to 0.87 at approximately four weeks. Responsiveness of the ROMS was greater than that of the SF-12 and less than that of the joint-specific questionnaires. The ROMS is compatible with routine clinical process and has good psychometric properties in patients with shoulder, hip, and knee disorders. It can be used as a primary outcome tool for large observational studies and can supplement more specific tools in controlled studies. The ROMS was developed as a tool to measure and monitor the clinical status of the musculoskeletal system in a population of patients during and after treatment as well as over time. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  4. Flexibility training in preadolescent female athletes: Acute and long-term effects of intermittent and continuous static stretching.

    PubMed

    Donti, Οlyvia; Papia, Konstantina; Toubekis, Argyris; Donti, Anastasia; Sands, William A; Bogdanis, Gregory C

    2018-07-01

    This study compared the acute and long-term effects of intermittent and continuous static stretching training on straight leg raise range of motion (ROM). Seventy-seven preadolescent female gymnasts were divided into a stretching (n = 57), and a control group (n = 20). The stretching group performed static stretching of the hip extensors of both legs, three times per week for 15 weeks. One leg performed intermittent (3 × 30 s with 30 s rest) while the other leg performed continuous stretching (90 s). ROM pre- and post-stretching was measured at baseline, on weeks 3, 6, 9, 12, 15 and after 2 weeks of detraining. ROM was increased during both intermittent and continuous stretching training, but remained unchanged in the control group. Intermittent stretching conferred a larger improvement in ROM compared to both continuous stretching and control from week 3, until the end of training, and following detraining (p = 0.045 to 0.001 and d = 0.80 to 1.41). During detraining, ROM after the intermittent protocol decreased (p = 0.001), while it was maintained after the continuous protocol (p = 0.36). Acute increases in ROM following the intermittent stretching were also larger than in the continuous (p = 0.038). Intermittent stretching was more effective than continuous, for both long-term and acute ROM enhancement in preadolescent female athletes.

  5. Reduced order modeling of fluid/structure interaction.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barone, Matthew Franklin; Kalashnikova, Irina; Segalman, Daniel Joseph

    2009-11-01

    This report describes work performed from October 2007 through September 2009 under the Sandia Laboratory Directed Research and Development project titled 'Reduced Order Modeling of Fluid/Structure Interaction.' This project addresses fundamental aspects of techniques for construction of predictive Reduced Order Models (ROMs). A ROM is defined as a model, derived from a sequence of high-fidelity simulations, that preserves the essential physics and predictive capability of the original simulations but at a much lower computational cost. Techniques are developed for construction of provably stable linear Galerkin projection ROMs for compressible fluid flow, including a method for enforcing boundary conditions that preservesmore » numerical stability. A convergence proof and error estimates are given for this class of ROM, and the method is demonstrated on a series of model problems. A reduced order method, based on the method of quadratic components, for solving the von Karman nonlinear plate equations is developed and tested. This method is applied to the problem of nonlinear limit cycle oscillations encountered when the plate interacts with an adjacent supersonic flow. A stability-preserving method for coupling the linear fluid ROM with the structural dynamics model for the elastic plate is constructed and tested. Methods for constructing efficient ROMs for nonlinear fluid equations are developed and tested on a one-dimensional convection-diffusion-reaction equation. These methods are combined with a symmetrization approach to construct a ROM technique for application to the compressible Navier-Stokes equations.« less

  6. Relaxed Open Mouth reciprocity favours playful contacts in South American sea lions (Otaria flavescens).

    PubMed

    Llamazares-Martín, Clara; Scopa, Chiara; Guillén-Salazar, Federico; Palagi, Elisabetta

    2017-07-01

    Fine-tuning communication is well documented in mammalian social play which relies on a large variety of specific and non-specific signals. Facial expressions are one of the most frequent patterns in play communication. The reciprocity of facial signals expressed by the players provides information on their reciprocal attentional state and on the correct perception/decoding of the signal itself. Here, for the first time, we explored the Relaxed Open Mouth (ROM), a widespread playful facial expression among mammals, in the South American sea lion (Otaria flavescens). In this species, like many others, ROM appears to be used as a playful signal as distinct from merely being a biting action. ROM was often reciprocated by players. Even though ROM did not vary in frequency of emission as a function of the number of players involved, it was reciprocated more often during dyadic encounters, in which the players had the highest probability to engage in a face-to-face interaction. Finally, we found that it was the reciprocation of ROMs, more than their frequency performance, that was effective in prolonging playful bouts. In conclusion, ROM is widespread in many social mammals and O. flavescens is not an exception. At least in those species for which quantitative data are available, ROM seems to be characterized by similar design features clearly indicating that the signal underwent to similar selective pressures. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Range of motion exercise of temporo-mandibular joint with hot pack increases occlusal force in patients with Duchenne muscular dystrophy.

    PubMed

    Nozaki, S; Kawai, M; Shimoyama, R; Futamura, N; Matsumura, T; Adachi, K; Kikuchi, Y

    2010-12-01

    The purpose of this study is to evaluate whether the range of motion exercise of the temporo-mandibular joint (jaw ROM exercise) with a hot pack and massage of the masseter muscle improve biting disorder in Duchenne muscular dystrophy (DMD). The subjects were 18 DMD patients (21.3+/- 4.1 years old). The jaw ROM exercise consisted of therapist-assisted training (2 times a week) and self-training (before each meal every day). The therapist-assisted training consisted of the application of a hot pack on the cheek of the masseter muscle region (15 minutes), the massage of the masseter (10 minutes), and jaw ROM exercise (5 minutes). The self-training involved jaw ROM exercise by opening the mouth to the maximum degree, ten times. These trainings continued for six months. Outcomes were evaluated by measuring the greatest occlusal force and the distance at the maximum degree of mouth opening between an incisor of the top and that of the bottom. Six months later, the greatest occlusal force had increased significantly compared with that at the start of jaw ROM exercise (intermediate values: from 73.8N to 97.3N) (p = 0.005) as determined by the Friedman test and Scheffi's nonparametric test. The patients' satisfaction with meals increased. However, the maximum degree of mouth opening did not change after six months of jaw ROM exercise. Jaw ROM exercise in DMD is effective for increasing the greatest occlusal force.

  8. Multi-Axis Prosthetic Knee Resembles Alpine Skiing Movements of an Intact Leg

    PubMed Central

    Demšar, Ivan; Duhovnik, Jože; Lešnik, Blaž; Supej, Matej

    2015-01-01

    The purpose of the study was to analyse the flexion angles of the ski boot, ankle and knee joints of an above-knee prosthesis and to compare them with an intact leg and a control group of skiers. One subject with an above-knee amputation of the right leg and eight healthy subjects simulated the movement of a skiing turn by performing two-leg squats in laboratory conditions. By adding additional loads in proportion to body weight (BW; +1/3 BW, +2/3 BW, +3/3 BW), various skiing regimes were simulated. Change of Flexion Angle (CoFA) and Range of Motion (RoM) in the ski boot, ankle and knee joints were calculated and compared. An average RoM in the skiing boot on the side of prosthesis (4.4 ± 1.1°) was significantly lower compared to an intact leg (5.9 ± 1.8°) and the control group (6.5 ± 2.3°). In the ankle joint, the average RoM was determined to be 13.2±2.9° in the prosthesis, 12.7 ± 2.8° in an intact leg and 14.8±3.6 in the control group. However, the RoM of the knee joint in the prosthesis (42.2 ± 4.2°) was significantly larger than that of the intact leg (34.7 ± 4.4°). The average RoM of the knee joint in the control group was 47.8 ± 5.4°. The influences of additional loads on the kinematics of the lower extremities were different on the side of the prosthesis and on the intact leg. In contrast, additional loads did not produce any significant differences in the control group. Although different CoFAs in the ski boot, ankle and knee joints were used, an above-knee prosthesis with a built-in multi-axis prosthetic knee enables comparable leg kinematics in simulated alpine skiing. Key points The RoM in the ski boot on the side of the prosthetic leg was smaller than the RoM of the intact leg and the control group of healthy subjects. The RoM in the ankle joint of prosthetic leg was comparable to that of the intact leg and the control group of healthy subjects. The RoM in the prosthetic knee joint was greater than the RoM in the knee joint of the intact leg and smaller than that of the control group. The total knee flexions in the laboratory measurements were comparable with field measurements. Additional load affects the RoM of the ski boot, ankle and knee joints for the amputated skier in both legs. No significant influence from the additional load was found on the RoM in the control group of healthy subjects. The above-knee prosthesis with a multiple-axis prosthetic knee reproduces the alpine skiing kinematics of an intact leg. PMID:26664282

  9. Non-Faradaic electrochemical detection of protein interactions by integrated neuromorphic CMOS sensors.

    PubMed

    Jacquot, Blake C; Muñoz, Nini; Branch, Darren W; Kan, Edwin C

    2008-05-15

    Electronic detection of the binding event between biotinylated bovine serum albumen (BSA) and streptavidin is demonstrated with the chemoreceptive neuron MOS (CnuMOS) device. Differing from the ion-sensitive field-effect transistors (ISFET), CnuMOS, with the potential of the extended floating gate determined by both the sensing and control gates in a neuromorphic style, can provide protein detection without requiring analyte reference electrodes. In comparison with the microelectrode arrays, measurements are gathered through purely capacitive, non-Faradaic interactions across insulating interfaces. By using a (3-glycidoxypropyl)trimethoxysilane (3-GPS) self-assembled monolayer (SAM) as a simple covalent link for attaching proteins to a silicon dioxide sensing surface, a fully integrated, electrochemical detection platform is realized for protein interactions through monotone large-signal measurements or small-signal impedance spectroscopy. Calibration curves were created to coordinate the sensor response with ellipsometric measurements taken on witness samples. By monitoring the film thickness of streptavidin capture, a sensitivity of 25ng/cm2 or 2A of film thickness was demonstrated. With an improved noise floor the sensor can detect down to 2ng/(cm2mV) based on the calibration curve. AC measurements are shown to significantly reduce long-term sensor drift. Finally, a noise analysis of electrochemical data indicates 1/f(alpha) behavior with a noise floor beginning at approximately 1Hz.

  10. Flexible integrated circuits and multifunctional electronics based on single atomic layers of MoS2 and graphene

    NASA Astrophysics Data System (ADS)

    Amani, Matin; Burke, Robert A.; Proie, Robert M.; Dubey, Madan

    2015-03-01

    Two-dimensional materials, such as graphene and its analogues, have been investigated by numerous researchers for high performance flexible and conformal electronic systems, because they offer the ultimate level of thickness scaling, atomically smooth surfaces and high crystalline quality. Here, we use layer-by-layer transfer of large area molybdenum disulphide (MoS2) and graphene grown by chemical vapor deposition (CVD) to demonstrate electronics on flexible polyimide (PI) substrates. On the same PI substrate, we are able to simultaneously fabricate MoS2 based logic, non-volatile memory cells with graphene floating gates, photo-detectors and MoS2 transistors with tunable source and drain contacts. We are also able to demonstrate that these flexible heterostructure devices have very high electronic performance, comparable to four point measurements taken on SiO2 substrates, with on/off ratios >107 and field effect mobilities as high as 16.4 cm2 V-1 s-1. Additionally, the heterojunctions show high optoelectronic sensitivity and were operated as photodetectors with responsivities over 30 A W-1. Through local gating of the individual graphene/MoS2 contacts, we are able to tune the contact resistance over the range of 322-1210 Ω mm for each contact, by modulating the graphene work function. This leads to devices with tunable and multifunctional performance that can be implemented in a conformable platform.

  11. Flexible integrated circuits and multifunctional electronics based on single atomic layers of MoS2 and graphene.

    PubMed

    Amani, Matin; Burke, Robert A; Proie, Robert M; Dubey, Madan

    2015-03-20

    Two-dimensional materials, such as graphene and its analogues, have been investigated by numerous researchers for high performance flexible and conformal electronic systems, because they offer the ultimate level of thickness scaling, atomically smooth surfaces and high crystalline quality. Here, we use layer-by-layer transfer of large area molybdenum disulphide (MoS2) and graphene grown by chemical vapor deposition (CVD) to demonstrate electronics on flexible polyimide (PI) substrates. On the same PI substrate, we are able to simultaneously fabricate MoS2 based logic, non-volatile memory cells with graphene floating gates, photo-detectors and MoS2 transistors with tunable source and drain contacts. We are also able to demonstrate that these flexible heterostructure devices have very high electronic performance, comparable to four point measurements taken on SiO2 substrates, with on/off ratios >10(7) and field effect mobilities as high as 16.4 cm(2) V(-1) s(-1). Additionally, the heterojunctions show high optoelectronic sensitivity and were operated as photodetectors with responsivities over 30 A W(-1). Through local gating of the individual graphene/MoS2 contacts, we are able to tune the contact resistance over the range of 322-1210 Ω mm for each contact, by modulating the graphene work function. This leads to devices with tunable and multifunctional performance that can be implemented in a conformable platform.

  12. Evaluation of the FIR Example using Xilinx Vivado High-Level Synthesis Compiler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jin, Zheming; Finkel, Hal; Yoshii, Kazutomo

    Compared to central processing units (CPUs) and graphics processing units (GPUs), field programmable gate arrays (FPGAs) have major advantages in reconfigurability and performance achieved per watt. This development flow has been augmented with high-level synthesis (HLS) flow that can convert programs written in a high-level programming language to Hardware Description Language (HDL). Using high-level programming languages such as C, C++, and OpenCL for FPGA-based development could allow software developers, who have little FPGA knowledge, to take advantage of the FPGA-based application acceleration. This improves developer productivity and makes the FPGA-based acceleration accessible to hardware and software developers. Xilinx Vivado HLSmore » compiler is a high-level synthesis tool that enables C, C++ and System C specification to be directly targeted into Xilinx FPGAs without the need to create RTL manually. The white paper [1] published recently by Xilinx uses a finite impulse response (FIR) example to demonstrate the variable-precision features in the Vivado HLS compiler and the resource and power benefits of converting floating point to fixed point for a design. To get a better understanding of variable-precision features in terms of resource usage and performance, this report presents the experimental results of evaluating the FIR example using Vivado HLS 2017.1 and a Kintex Ultrascale FPGA. In addition, we evaluated the half-precision floating-point data type against the double-precision and single-precision data type and present the detailed results.« less

  13. Kawachin na ri kitzij-kipixab' Qanan Qatat--Florezcan las palabras de los hombres de maiz (The Blossoming of Our Ancestors' Words). [CD-ROM].

    ERIC Educational Resources Information Center

    Academy for Educational Development, Washington, DC.

    This CD-ROM is part of an interactive and dynamic multimedia package of information and games for learning K'iche' and Ixil. This CD-ROM contains selected radio programs for preschool students, scripted from the four storybooks created by Project "Enlace Quiche." It includes stories in K'iche', Ixil, and Spanish. (VWL)

  14. Distributive Learning in Introductory Chemical Engineering: University Students' Learning, Motivation, and Attitudes Using a CD-ROM

    ERIC Educational Resources Information Center

    Greene, Barbara A.; Dillon, Connie; Crynes, Billy

    2003-01-01

    This article reports a study in which student performance and approaches to study in a CD-ROM version of a chemical engineering course were examined. The study consists of three phases. The purpose of phase 1 was to evaluate of the efficacy of CD-ROM for this content and student population. Therefore, we compared the performance of students who…

  15. In Praise of Mr. S. Platter and His Marvelous, Magnificent CD ROM Laser Disc Index for ERIC and PSYCHLIT.

    ERIC Educational Resources Information Center

    Huffman, Robert F.

    These instructions are designed to help patrons of the University of Missouri-Columbia library perform searches on PSYCHLIT, a CD-ROM (compact disc, read only memory) version of the Psych Abstracts database, and a CD-ROM version of the ERIC database, both produced by SilverPlatter Information Services. Basic information is provided about the disk…

  16. Core cerebrospinal fluid biomarker profile in cerebral amyloid angiopathy: A meta-analysis.

    PubMed

    Charidimou, Andreas; Friedrich, Jan O; Greenberg, Steven M; Viswanathan, Anand

    2018-02-27

    To perform a meta-analysis of 4 core CSF biomarkers (β-amyloid [Aβ]42, Aβ40, total tau [t-tau], and phosphorylated tau [p-tau]) to assess which of these are most altered in sporadic cerebral amyloid angiopathy (CAA). We systematically searched PubMed for eligible studies reporting data on CSF biomarkers reflecting amyloid precursor protein metabolism (Aβ42, Aβ40), neurodegeneration (t-tau), and tangle pathology (p-tau) in symptomatic sporadic CAA cohorts vs controls and patients with Alzheimer disease (AD). Biomarker performance was assessed in random-effects meta-analysis based on ratio of mean (RoM) biomarker concentrations: (1) in patients with CAA vs healthy controls and (2) in patients with CAA vs patients with AD. RoM >1 indicates higher biomarker concentration in patients with CAA vs comparison population and RoM <1 indicates higher concentration in comparison groups. Three studies met inclusion criteria. These comprised 5 CAA patient cohorts (n = 59 patients) vs healthy controls (n = 94 cases) and AD cohorts (n = 158). Three core biomarkers differentiated CAA from controls: CSF Aβ42 (RoM 0.49, 95% confidence interval [CI] 0.38-0.64, p < 0.003), Aβ40 (RoM 0.70, 95% CI 0.63-0.78, p < 0.0001), and t-tau (RoM 1.54, 95% CI 1.15-2.07, p = 0.004); p-tau was marginal (RoM 1.24, 95% CI 0.99-1.54, p = 0.062). Differentiation between CAA and AD was strong for CSF Aβ40 (RoM 0.76, 95% CI 0.69-0.83, p < 0.0001), but not Aβ42 (RoM 1.00; 95% CI 0.81-1.23, p = 0.970). For t-tau and p-tau, average CSF ratios in patients with CAA vs patients with AD were 0.63 (95% CI 0.54-0.74, p < 0.0001) and 0.60 (95% CI 0.50-0.71, p < 0.0001), respectively. Specific CSF patterns of Aβ42, Aβ40, t-tau, and p-tau might serve as molecular biomarkers of CAA, but analyses in larger CAA cohorts are needed. © 2018 American Academy of Neurology.

  17. THORACOLUMBAR RANGE OF MOTION IN BASEBALL PITCHERS AND POSITION PLAYERS

    PubMed Central

    Lynall, Robert; Williams, Jeffrey G.; Wong, Regan; Onuki, Takashi; Meister, Keith

    2013-01-01

    Introduction/Background: Optimal baseball throwing mechanics require a significant contribution of thoracolumbar motion, particularly in the sagittal and transverse planes. This motion is key for proper transmission of forces from the lower to upper extremity, thereby minimizing a throwing athlete's risk of injury and maximizing athletic performance. Purpose: To define the active‐assisted thoracolumbar ROM of both baseball pitchers and position players and to compare these motions both within and between groups. Methods: Fifty‐six asymptomatic, collegiate and minor league baseball pitchers and 42 position players volunteered to participate. Active‐assisted thoracolumbar flexion, extension, and bilateral rotation ROM, were measured in a standing position, using two bubble inclinometers. Two‐tailed t tests were used to determine differences in ROM between and within the pitchers and position players. Results: The pitchers had significantly more rotation to the non‐throwing arm side as compared to the position players (p = .007, effect size = .61). The pitchers also had more rotation to the non‐throwing arm side as compared to their throwing side (p = .006, effect size = .47). There were no other significant differences between the pitchers and the position players (p > .53). Furthermore, the position players did not have a side‐to‐side rotation difference (p = .99). Conclusions: Pitchers have a greater amount of rotation ROM towards the non‐throwing arm side as compared to position players. Pitchers also have a greater amount of rotation ROM to the non‐throwing arm side as compared to their throwing side rotation. Because pitchers often present with posterior shoulder tightness and subsequent altered shoulder horizontal adduction and internal rotation ROM, the increase in non‐throwing side rotation ROM may occur in response to these adaptations. More specifically, this increase in non‐throwing side trunk rotation ROM may allow such athletes to bring the arm across the body during the follow‐through phase of the throwing motion despite posterior shoulder tightness. However, future research is necessary to investigate this relationship. Based on these results, clinicians should consider these thoracolumbar ROM adaptations in the prevention, evaluation, and treatment of baseball players. Level of Evidence: 2b PMID:24377063

  18. Reference values for anxiety questionnaires: the Leiden Routine Outcome Monitoring Study.

    PubMed

    Schulte-van Maaren, Yvonne W M; Giltay, Erik J; van Hemert, Albert M; Zitman, Frans G; de Waal, Margot W M; Carlier, Ingrid V E

    2013-09-25

    The monitoring of patients with an anxiety disorder can benefit from Routine Outcome Monitoring (ROM). As anxiety disorders differ in phenomenology, several anxiety questionnaires are included in ROM: Brief Scale for Anxiety (BSA), PADUA Inventory Revised (PI-R), Panic Appraisal Inventory (PAI), Penn State Worry Questionnaire (PSWQ), Worry Domains Questionnaire (WDQ), Social Interaction, Anxiety Scale (SIAS), Social Phobia Scale (SPS), and the Impact of Event Scale-Revised (IES-R). We aimed to generate reference values for both 'healthy' and 'clinically anxious' populations for these anxiety questionnaires. We included 1295 subjects from the general population (ROM reference-group) and 5066 psychiatric outpatients diagnosed with a specific anxiety disorder (ROM patient-group). The MINI was used as diagnostic device in both the ROM reference group and the ROM patient group. To define limits for one-sided reference intervals (95th percentile; P95) the outermost 5% of observations were used. Receiver Operating Characteristics (ROC) analyses were used to yield alternative cut-off values for the anxiety questionnaires. For the ROM reference-group the mean age was 40.3 years (SD=12.6), and for the ROM patient-group it was 36.5 years (SD=11.9). Females constituted 62.8% of the reference-group and 64.4% of the patient-group. P95 ROM reference group cut-off values for reference versus clinically anxious populations were 11 for the BSA, 43 for the PI-R, 37 for the PAI Anticipated Panic, 47 for the PAI Perceived Consequences, 65 for the PAI Perceived Self-efficacy, 66 for the PSWQ, 74 for the WDQ, 32 for the SIAS, 19 for the SPS, and 36 for IES-R. ROC analyses yielded slightly lower reference values. The discriminative power of all eight anxiety questionnaires was very high. Substantial non-response and limited generalizability. For eight anxiety questionnaires a comprehensive set of reference values was provided. Reference values were generally higher in women than in men, implying the use of gender-specific cut-off values. Each instrument can be offered to every patient with MAS disorders to make responsible decisions about continuing, changing or terminating therapy. © 2013 Elsevier B.V. All rights reserved.

  19. Association of lower extremity range of motion and muscle strength with physical performance of community-dwelling older women.

    PubMed

    Jung, Hungu; Yamasaki, Masahiro

    2016-12-08

    Reduced lower extremity range of motion (ROM) and muscle strength are related to functional disability in older adults who cannot perform one or more activities of daily living (ADL) independently. The purpose of this study was to determine which factors of seven lower extremity ROMs and two muscle strengths play dominant roles in the physical performance of community-dwelling older women. Ninety-five community-dwelling older women (mean age ± SD, 70.7 ± 4.7 years; age range, 65-83 years) were enrolled in this study. Seven lower extremity ROMs (hip flexion, hip extension, knee flexion, internal and external hip rotation, ankle dorsiflexion, and ankle plantar flexion) and two muscle strengths (knee extension and flexion) were measured. Physical performance tests, including functional reach test (FRT), 5 m gait test, four square step test (FSST), timed up and go test (TUGT), and five times sit-to-stand test (FTSST) were performed. Stepwise regression models for each of the physical performance tests revealed that hip extension ROM and knee flexion strength were important explanatory variables for FRT, FSST, and FTSST. Furthermore, ankle plantar flexion ROM and knee extension strength were significant explanatory variables for the 5 m gait test and TUGT. However, ankle dorsiflexion ROM was a significant explanatory variable for FRT alone. The amount of variance on stepwise multiple regression for the five physical performance tests ranged from 25 (FSST) to 47% (TUGT). Hip extension, ankle dorsiflexion, and ankle plantar flexion ROMs, as well as knee extension and flexion strengths may play primary roles in the physical performance of community-dwelling older women. Further studies should assess whether specific intervention programs targeting older women may achieve improvements in lower extremity ROM and muscle strength, and thereby play an important role in the prevention of dependence on daily activities and loss of physical function, particularly focusing on hip extension, ankle dorsiflexion, and ankle plantar flexion ROMs as well as knee extension and flexion strength.

  20. Analyses of associations between reactive oxygen metabolites and antioxidant capacity and related factors among healthy adolescents.

    PubMed

    Tamae, Kazuyoshi; Eto, Toshiharu; Aoki, Kazuhiro; Nakamaru, Shingo; Koshikawa, Kazunori; Sakuma, Kazuhiko; Hirano, Takeshi

    2013-12-01

    Evidence based on epidemiologic investigations using biochemical parameter is meaningful for health promotion and administration among adolescents. We conducted Reactive Oxygen Metabolites (ROM) and Biological Antioxidant Potentials (BAP) tests, along with a questionnaire survey, for a sample of 74 high school students (16.51±0.11 years of aged mean±SE), to investigate the associations between ROM, BAP, and related factors, including BMI and blood biochemical data. Venous blood samples (approximately 7cc) were collected. At the same time, each individual's information was obtained from the questionnaire. The mental health status was investigated using the Center for Epidemiologic Study Depression scale (CES-D) included in the same questionnaire. The mean values and standard errors of all variables were calculated. In addition, the relationships between ROM and BAP with these factors were analyzed. The results revealed the preferred levels of ROM (261.95 ± 9.52 U.CARR) and, BAP (2429.89±53.39 µmol/L) and blood biochemical data. Few significant relationships between two markers and related factors were found. So, we detected a cluster with an imbalance between ROM and BAP, which means low antioxidant ability, whereas the other clusters had conditions with moderate balance or good balance between them. Moreover, we determined the Oxidative stress-Antioxidant capacity ratio (OAR), using the ROM and BAP values, in order to clarify the characteristic of the detected clusters.However, comparative analyses across the three clusters did not yield significant differences in all related factors. No correlations between ROM, BAP and related factors were indicated, although significant association between ROM and BAP was observed (R2=0.1156, R=0.340, P=0.013). The reason for these results can be explained by the influences of good health and young age. On the other hand, present study suggests that some latent problems among adolescents may be related to unhealthy conditions in the future. Also, this study indicated that ROM and BAP may be useful as markers of the oxidative stress status. After this, further investigations using biomarkers based on epidemiologic design should be conducted, to reveal the reliability of the present results.

  1. A Low-Cost CMOS Programmable Temperature Switch

    PubMed Central

    Li, Yunlong; Wu, Nanjian

    2008-01-01

    A novel uncalibrated CMOS programmable temperature switch with high temperature accuracy is presented. Its threshold temperature Tth can be programmed by adjusting the ratios of width and length of the transistors. The operating principles of the temperature switch circuit is theoretically explained. A floating gate neural MOS circuit is designed to compensate automatically the threshold temperature Tth variation that results form the process tolerance. The switch circuit is implemented in a standard 0.35 μm CMOS process. The temperature switch can be programmed to perform the switch operation at 16 different threshold temperature Tths from 45—120°C with a 5°C increment. The measurement shows a good consistency in the threshold temperatures. The chip core area is 0.04 mm2 and power consumption is 3.1 μA at 3.3V power supply. The advantages of the temperature switch are low power consumption, the programmable threshold temperature and the controllable hysteresis. PMID:27879871

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jin, Zheming; Yoshii, Kazutomo; Finkel, Hal

    Open Computing Language (OpenCL) is a high-level language that enables software programmers to explore Field Programmable Gate Arrays (FPGAs) for application acceleration. The Intel FPGA software development kit (SDK) for OpenCL allows a user to specify applications at a high level and explore the performance of low-level hardware acceleration. In this report, we present the FPGA performance and power consumption results of the single-precision floating-point vector add OpenCL kernel using the Intel FPGA SDK for OpenCL on the Nallatech 385A FPGA board. The board features an Arria 10 FPGA. We evaluate the FPGA implementations using the compute unit duplication andmore » kernel vectorization optimization techniques. On the Nallatech 385A FPGA board, the maximum compute kernel bandwidth we achieve is 25.8 GB/s, approximately 76% of the peak memory bandwidth. The power consumption of the FPGA device when running the kernels ranges from 29W to 42W.« less

  3. Spin switches for compact implementation of neuron and synapse

    NASA Astrophysics Data System (ADS)

    Quang Diep, Vinh; Sutton, Brian; Behin-Aein, Behtash; Datta, Supriyo

    2014-06-01

    Nanomagnets driven by spin currents provide a natural implementation for a neuron and a synapse: currents allow convenient summation of multiple inputs, while the magnet provides the threshold function. The objective of this paper is to explore the possibility of a hardware neural network implementation using a spin switch (SS) as its basic building block. SS is a recently proposed device based on established technology with a transistor-like gain and input-output isolation. This allows neural networks to be constructed with purely passive interconnections without intervening clocks or amplifiers. The weights for the neural network are conveniently adjusted through analog voltages that can be stored in a non-volatile manner in an underlying CMOS layer using a floating gate low dropout voltage regulator. The operation of a multi-layer SS neural network designed for character recognition is demonstrated using a standard simulation model based on coupled Landau-Lifshitz-Gilbert equations, one for each magnet in the network.

  4. Experimental demonstration of a real-time high-throughput digital DC blocker for compensating ADC imperfections in optical fast-OFDM receivers.

    PubMed

    Zhang, Lu; Ouyang, Xing; Shao, Xiaopeng; Zhao, Jian

    2016-06-27

    Performance degradation induced by the DC components at the output of real-time analogue-to-digital converter (ADC) is experimentally investigated for optical fast-OFDM receiver. To compensate this degradation, register transfer level (RTL) circuits for real-time digital DC blocker with 20GS/s throughput are proposed and implemented in field programmable gate array (FPGA). The performance of the proposed real-time digital DC blocker is experimentally investigated in a 15Gb/s optical fast-OFDM system with intensity modulation and direct detection over 40 km standard single-mode fibre. The results show that the fixed-point DC blocker has negligible performance penalty compared to the offline floating point one, and can overcome the error floor of the fast OFDM receiver caused by the DC components from the real-time ADC output.

  5. Kink effect in ultrathin FDSOI MOSFETs

    NASA Astrophysics Data System (ADS)

    Park, H. J.; Bawedin, M.; Choi, H. G.; Cristoloveanu, S.

    2018-05-01

    Systematic experiments demonstrate the presence of the kink effect even in FDSOI MOSFETs. The back-gate bias controls the kink effect via the formation of a back accumulation channel. The kink is more or less pronounced according to the film thickness and channel length. However, in ultrathin (<10 nm) and/or very short transistors (L < 50 nm), the kink is totally absent as a consequence of super-coupling effect. For the first time, thanks to the availability of body contacts, the body potential is probed to evidence the impact of majority carrier accumulation and drain pulse duration on the kink effect onset. He is currently working toward the Ph.D. degree in FDSOI device characterization and simulation at a laboratory of IMEP-lahc, Université Grenoble Alpes, Minatec, Grenoble, France. His research interests include residual floating body effects, electrical characterization, and device simulation for ultra FDSOI MOSFETs.

  6. Archive of mass spectral data files on recordable CD-ROMs and creation and maintenance of a searchable computerized database.

    PubMed

    Amick, G D

    1999-01-01

    A database containing names of mass spectral data files generated in a forensic toxicology laboratory and two Microsoft Visual Basic programs to maintain and search this database is described. The data files (approximately 0.5 KB/each) were collected from six mass spectrometers during routine casework. Data files were archived on 650 MB (74 min) recordable CD-ROMs. Each recordable CD-ROM was given a unique name, and its list of data file names was placed into the database. The present manuscript describes the use of search and maintenance programs for searching and routine upkeep of the database and creation of CD-ROMs for archiving of data files.

  7. TAG CD-ROM

    NASA Technical Reports Server (NTRS)

    Rivera, Myrna Syamara

    1995-01-01

    The purpose of this project was to produce a CD-ROM for the Technology Applications Group. The CD was being developed to allow interested people, organizations, or companies to view the technologies available to them that were developed by NASA research. The CD's main audience however, is any small business. The CD will give the small business an opportunity to see what technologies are available in an inexpensive manner. Most companies probably have a CD-ROM drive on their computers but may not have access to the internet. By using only the internet to inform on the technologies, NASA was not considering a large segment of the population. The CD-ROM can now cover that group of the population.

  8. The planetary data system educational CD-ROM

    NASA Technical Reports Server (NTRS)

    Guinness, E. A.; Arvidson, R. E.; Martin, M.; Dueck, S.

    1993-01-01

    The Planetary Data System (PDS) is producing a special educational CD-ROM that contains samples of PDS datasets and is expected to be released in 1993. The CD-ROM will provide university-level instructors with PDS-compatible materials and information that can be used to construct student problem sets using real datasets. The main purposes of the CD-ROM are to facilitate wide use of planetary data and to introduce a large community to the PDS. To meet these objectives the Educational CD-ROM will also contain software to manipulate the data, background discussions about scientific questions that can be addressed with the data, and a suite of exercises that illustrate analysis techniques. Students will also be introduced to the SPICE concept, which is a new way of maintaining geometry and instrument information. The exercises will be presented at the freshman through graduate student levels. With simplification, some of the material should also be of use at the high school level.

  9. Data Collection and Analysis Using Wearable Sensors for Monitoring Knee Range of Motion after Total Knee Arthroplasty

    PubMed Central

    Chiang, Chih-Yen; Chen, Kun-Hui; Liu, Kai-Chun; Hsu, Steen Jun-Ping; Chan, Chia-Tai

    2017-01-01

    Total knee arthroplasty (TKA) is the most common treatment for degenerative osteoarthritis of that articulation. However, either in rehabilitation clinics or in hospital wards, the knee range of motion (ROM) can currently only be assessed using a goniometer. In order to provide continuous and objective measurements of knee ROM, we propose the use of wearable inertial sensors to record the knee ROM during the recovery progress. Digitalized and objective data can assist the surgeons to control the recovery status and flexibly adjust rehabilitation programs during the early acute inpatient stage. The more knee flexion ROM regained during the early inpatient period, the better the long-term knee recovery will be and the sooner early discharge can be achieved. The results of this work show that the proposed wearable sensor approach can provide an alternative for continuous monitoring and objective assessment of knee ROM recovery progress for TKA patients compared to the traditional goniometer measurements. PMID:28241434

  10. International journal of computational fluid dynamics real-time prediction of unsteady flow based on POD reduced-order model and particle filter

    NASA Astrophysics Data System (ADS)

    Kikuchi, Ryota; Misaka, Takashi; Obayashi, Shigeru

    2016-04-01

    An integrated method consisting of a proper orthogonal decomposition (POD)-based reduced-order model (ROM) and a particle filter (PF) is proposed for real-time prediction of an unsteady flow field. The proposed method is validated using identical twin experiments of an unsteady flow field around a circular cylinder for Reynolds numbers of 100 and 1000. In this study, a PF is employed (ROM-PF) to modify the temporal coefficient of the ROM based on observation data because the prediction capability of the ROM alone is limited due to the stability issue. The proposed method reproduces the unsteady flow field several orders faster than a reference numerical simulation based on Navier-Stokes equations. Furthermore, the effects of parameters, related to observation and simulation, on the prediction accuracy are studied. Most of the energy modes of the unsteady flow field are captured, and it is possible to stably predict the long-term evolution with ROM-PF.

  11. Parallel Computation of the Regional Ocean Modeling System (ROMS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, P; Song, Y T; Chao, Y

    2005-04-05

    The Regional Ocean Modeling System (ROMS) is a regional ocean general circulation modeling system solving the free surface, hydrostatic, primitive equations over varying topography. It is free software distributed world-wide for studying both complex coastal ocean problems and the basin-to-global scale ocean circulation. The original ROMS code could only be run on shared-memory systems. With the increasing need to simulate larger model domains with finer resolutions and on a variety of computer platforms, there is a need in the ocean-modeling community to have a ROMS code that can be run on any parallel computer ranging from 10 to hundreds ofmore » processors. Recently, we have explored parallelization for ROMS using the MPI programming model. In this paper, an efficient parallelization strategy for such a large-scale scientific software package, based on an existing shared-memory computing model, is presented. In addition, scientific applications and data-performance issues on a couple of SGI systems, including Columbia, the world's third-fastest supercomputer, are discussed.« less

  12. Association between coffee consumption and an oxidative stress marker in women.

    PubMed

    Chen, Jui-Tung; Kotani, Kazuhiko

    2015-07-01

    Coffee is one of the major dietary modulators of oxidative stress conditions. Whether coffee consumption is associated with oxidative stress markers, such as derivatives of reactive oxygen metabolites (d-ROMs), remains to be investigated in women, despite one recent report describing their significant association in men. A total of 415 women (49 ± 9 years) attending a general clinic were evaluated regarding their self-reported coffee consumption habits and blood d-ROMs levels. Women who reported ≥ 3 cups/day of coffee consumption displayed a lower d-ROMs level than those who reported consuming 0-2 cups/day (336 ± 67 vs. 358 ± 80 Carr U; p < 0.05). In the multivariate-adjusted analysis, the association between coffee consumption and the d-ROMs level remained to be significant (p < 0.05). Daily coffee consumption (i.e., ≥ 3 cups) may be associated with a reduced oxidative stress status, as measured by the d-ROMs level, among women.

  13. EP and CD-ROM products - Current trends of production and market development -

    NASA Astrophysics Data System (ADS)

    Watanabe, Kazuhiko

    The printed books and magazines/journals have been, and still even now are, dominant materials for public reading and reference usage. Microform publications have been also adopted for library collection build-up, but it is still within a very limited scale and coverage. As the first "new media" product, we should approve the fact that "CD-ROM" keeps amazingly large information storage capacity and also quite flexible application utility. So far, among the firstly released CD-ROMS, bibliographic databases, both for Japanese and English publications, look already quite widely purchased and now installed in many workstations of libraries. The users should evaluate its cost-effectiveness not only by its great data storage capacity but also by its frequent usage merit for library work rationalization. Multiple applied usage of CD-ROM will surely serve to such library routine works as searching, cataloguing, reading list preparation, inventory checking and new order placing, etc. 'CD-ROM' is the first EP product for quite wide usage.

  14. 76 FR 59679 - Notice of Intent to Hold Public Meetings and Hear Public Comment on the Proposed New Jersey-New...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-27

    ... Street, NE, Room 2A, Washington, DC 20426, (202) 502-8371. CD-ROM copies of the draft EIS were mailed to.... A limited number of hard copies and CD-ROMs are available from the Public Reference Room identified above. Please note that copies of the CD-ROM were mailed with a postcard that included a docket number...

  15. Is lower hip range of motion a risk factor for groin pain in athletes? A systematic review with clinical applications

    PubMed Central

    Tak, Igor; Engelaar, Leonie; Gouttebarge, Vincent; Barendrecht, Maarten; Van den Heuvel, Sylvia; Kerkhoffs, Gino; Langhout, Rob; Stubbe, Janine; Weir, Adam

    2017-01-01

    Background Whether hip range of motion (ROM) is a risk factor for groin pain in athletes is not known. Objectives To systematically review the relationship between hip ROM and groin pain in athletes in cross-sectional/case–control and prospective studies. Study design Systematic review, prospectively registered (PROSPERO) according to PRISMA guidelines. Methods Pubmed, Embase, CINAHL and SPORTDiscus were systematically searched up to December 2015. Two authors performed study selection, data extraction/analysis, quality assessment (Critical Appraisal Skills Programme) and strength of evidence synthesis. Results We identified seven prospective and four case–control studies. The total quality score ranged from 29% to 92%. Heterogeneity in groin pain classification, injury definitions and physical assessment precluded data pooling. There was strong evidence that total rotation of both hips below 85° measured at the pre-season screening was a risk factor for groin pain development. Strong evidence suggested that internal rotation, abduction and extension were not associated with the risk or presence of groin pain. Conclusion Total hip ROM is the factor most consistently related to groin pain in athletes. Screening for hip ROM is unlikely to correctly identify an athlete at risk of developing groin pain because of the small ROM differences found and poor ROM measurement properties. PMID:28432076

  16. Efficacy of a drug prevention CD-ROM intervention for adolescents.

    PubMed

    Williams, Christopher; Griffin, Kenneth W; Macaulay, Araxi P; West, Tara L; Gronewold, Elizabeth

    2005-01-01

    The purpose of the present study was to examine the efficacy of a substance abuse-preventive intervention using CD-ROM technology among adolescents in the sixth and seventh grades (12- to 13-years-old). The CD-ROM program used interactive audio and video content to teach social resistance skills, general personal and social competence skills, and normative education. Rates of substance-use behavior attitudes, knowledge, normative expectations, and related variables were examined. From approximately 23 schools, students (n = 123) were randomly assigned to either receive the CD-ROM preventive intervention (n = 61) or to serve as a control group (n = 62). Study participants were 50% male, predominantly white (75%), and 94% came from two-parent families. Self-report data were collected using a self-administered web-based survey. Findings indicated that there were significant intervention effects on pro-drug attitudes, normative expectations for peer and adult substance use, anxiety reduction skills, and relaxation skills knowledge, with intervention students reporting improved scores on these outcomes at the posttest relative to control students. Findings indicate that a substance abuse-preventive intervention derived from an effective, school-based prevention approach is efficacious when delivered using CD-ROM technology. Research is needed to determine potential differences in the efficacy of CD-ROM prevention tools delivered in schools compared to home settings.

  17. The effects of using a human patient simulator compared to a CD-ROM in teaching critical thinking and performance.

    PubMed

    Johnson, Don; Johnson, Sabine

    2014-01-01

    Military healthcare personnel, including nurse anesthetists, must have the knowledge and skills to care for the extensive, severe injuries incurred on the battlefield. No studies have compared the 2 teaching strategies of using the human patient simulator (HPS) and a CD-ROM in caring for combat injuries relative to critical thinking and performance using nurse anesthesia participants. A prospective, pretest-posttest experimental, mixed design (within and between) was used to determine if there were statistically significant differences in HPS and CD-ROM educational strategies relative to caring for patients who have trauma. Two instruments were used: critical thinking, which consisted of multiple-choice questions; and a combat performance instrument that measured ability to care for patients. A repeated analysis of variance and a least significant difference post-hoc test were used to analyze the data. The HPS group performed better than the CD-ROM and control groups relative to performance (P=.000) but not on critical thinking (P=.239). There was no difference between the CD-ROM and control group (P=.171) on the combat performance instrument. In this study, the HPS method of instruction was a more effective method of teaching than the CD-ROM approach.

  18. Oxidative Stress Measurement and Prediction of Epileptic Seizure in Children and Adults With Severe Motor and Intellectual Disabilities

    PubMed Central

    Morimoto, Masahito; Satomura, Shigeko; Hashimoto, Toshiaki; Ito, Etsuro; Kyotani, Shojiro

    2016-01-01

    Background The medical care of severe motor and intellectual disabilities (SMID) depends on the empirical medical care. Epileptic seizure specific to SMID is difficult to suppress using anti-epileptic drugs, and its tendency to persist for long periods poses an issue. The present study was undertaken to evaluate the relationship between epileptic seizure in cases with SMID and oxidative stress in the living body by examining endogenous antioxidants, the degree of oxidation (reactive oxygen metabolites (d-ROMs)), and the biological antioxidant potential (BAP) as indicators. Methods Target patients were 43 SMID epilepsy patients. Blood was sampled before breakfast and medication. As for the specimen, d-ROMs and BAP were measured using the free radical analyzer. Results The present study did not reveal any correlation between endogenous antioxidants (albumin) and the frequency of epileptic seizures. On the other hand, d-ROMs were correlated with the frequency of epileptic seizure. In particular, strong correlations between the frequency of epileptic seizures and the d-ROMs/BAP ratio as well as the BAP/d-ROMs ratio were noted. Conclusions These results indicate that the use of d-ROMs and BAP as biomarkers can provide a tool for predicting the prognosis of epileptic seizures in patients with SMID. PMID:27222671

  19. Oxidative Stress Measurement and Prediction of Epileptic Seizure in Children and Adults With Severe Motor and Intellectual Disabilities.

    PubMed

    Morimoto, Masahito; Satomura, Shigeko; Hashimoto, Toshiaki; Ito, Etsuro; Kyotani, Shojiro

    2016-06-01

    The medical care of severe motor and intellectual disabilities (SMID) depends on the empirical medical care. Epileptic seizure specific to SMID is difficult to suppress using anti-epileptic drugs, and its tendency to persist for long periods poses an issue. The present study was undertaken to evaluate the relationship between epileptic seizure in cases with SMID and oxidative stress in the living body by examining endogenous antioxidants, the degree of oxidation (reactive oxygen metabolites (d-ROMs)), and the biological antioxidant potential (BAP) as indicators. Target patients were 43 SMID epilepsy patients. Blood was sampled before breakfast and medication. As for the specimen, d-ROMs and BAP were measured using the free radical analyzer. The present study did not reveal any correlation between endogenous antioxidants (albumin) and the frequency of epileptic seizures. On the other hand, d-ROMs were correlated with the frequency of epileptic seizure. In particular, strong correlations between the frequency of epileptic seizures and the d-ROMs/BAP ratio as well as the BAP/d-ROMs ratio were noted. These results indicate that the use of d-ROMs and BAP as biomarkers can provide a tool for predicting the prognosis of epileptic seizures in patients with SMID.

  20. Measuring the effects of structural turnout suits on firefighter range of motion and comfort.

    PubMed

    Ciesielska-Wróbel, Izabela; DenHartog, Emiel; Barker, Roger

    2017-07-01

    Range of motion (ROM) can be restricted by wearing stiff and bulky clothing. This is particularly true of firefighter suits that are constructed using fabric layers to provide thermal protection from fire. This study developed an evaluation technique to quantify the loss of mobility associated with wearing firefighters' protective suits that were deliberately selected to represent similar ergonomic design features. The ROM of 10 firefighters was measured using electro-goniometers attached to their bodies while they wore uniforms and a reference outfit, and performed specific movements. The most restrictive uniform is the Bulky suit that contained additional layers of materials in sleeves and on the knees. The Traditional Suit was more ROM restrictive than Ergonomic. The subjective evaluation of suits supported the objective assessments provided by the electro-goniometers. A 3-D body scanning technique was employed to establish a correlation between the bulkiness of firefighter outfits and subject ROM. Practitioner Summary: This study presents a methodology for measurements of range of motion (ROM) in firefighters wearing personal protective equipment (PPE). Even small differences in designs of PPE may impact firefighters' ROM, which can be detected by electro-goniometers providing measurements if they are attached along the joint to measure limb angular movement.

  1. An immediate effect of axial neck rotation training with real time visual feedback using a smartphone inclinometer on improvement in axial neck rotation function.

    PubMed

    Park, Kyue-Nam; Kwon, Oh-Yun; Kim, Si-Hyun; Jeon, In-Cheol

    2017-03-01

    The purpose of this study was to compare the immediate effects of axial neck rotation training (Axi-NRT) with and without real-time visual feedback (VF) using a smartphone inclinometer on the range of motion (ROM) for axial neck rotation and the onset of compensatory neck lateral bending and extension during active neck rotation. Twenty participants with restricted ROM for neck rotation but no neck pain (21.1 ± 1.6 years and 8 males, 12 females) were recruited for Axi-NRT with VF, and twenty age- and gender-matched participants with restricted ROM for neck rotation were recruited for Axi-NRT without VF. Changes in ROM for neck rotation and the onset time of compensatory neck movement during active neck rotation were measured using an electromagnetic tracking system. Axi-NRT with VF was more effective in increasing ROM for neck rotation and decreasing and delaying the onset of compensatory neck movements during active neck rotation compared with Axi-NRT without VF. Repeated Axi-NRT using VF is useful to educate participants in maintaining the axis of the cervical spine and to increase ROM for axial neck rotation with less compensatory neck motion in participants with a restricted range of neck rotations.

  2. Qualitative evaluation of a colorectal cancer education CD-ROM for Community Health Aides/practitioners in Alaska.

    PubMed

    Cueva, Melany; Dignan, Mark; Lanier, Anne; Kuhnley, Regina

    2014-12-01

    Colorectal cancer (CRC) is an important contributor to the cancer burden among Alaska Native people. CRC is the leading incident cancer and the second leading cause of cancer mortality among Alaska Native people. Completing recommended CRC screening procedures has the potential to reduce both CRC incidence and mortality. "Taking Action Colorectal Health," a multidimensional audiovisual, interactive CD-ROM, incorporates adult education learning principles to provide Alaska's Community Health Aides/Practitioners with timely, medically accurate, and culturally relevant CRC place-based education. Providing this resource on CD-ROM empowers learning within communities and places where people live or choose to learn. The dynamic process of developing, implementing, and evaluating this CRC CD-ROM was informed by a sociocultural approach to share health messages. Within this approach, cultural values, beliefs, and behaviors are affirmed as a place of wisdom and resilience and built upon to provide context and meaning for health messaging. Alaska Native values that honor family, relationships, the land, storytelling, and humor were included in CD-ROM content. Between January and May 2012, 20 interviews were conducted with individuals who had used the CD-ROM. Four categorical themes emerged from analysis of interview transcripts: likeability, utilization, helpfulness, and behavior change. As a result of self-paced learning through stories, movies, and interactive games, respondents reported healthy behavior changes they were making for themselves, with their families and in their patient care practices. This CD-ROM is a culturally based practical course that increased knowledge and activities around colorectal cancer screening by Community Health Aides/Practitioners in Alaska.

  3. Optimization of rotamers prior to template minimization improves stability predictions made by computational protein design.

    PubMed

    Davey, James A; Chica, Roberto A

    2015-04-01

    Computational protein design (CPD) predictions are highly dependent on the structure of the input template used. However, it is unclear how small differences in template geometry translate to large differences in stability prediction accuracy. Herein, we explored how structural changes to the input template affect the outcome of stability predictions by CPD. To do this, we prepared alternate templates by Rotamer Optimization followed by energy Minimization (ROM) and used them to recapitulate the stability of 84 protein G domain β1 mutant sequences. In the ROM process, side-chain rotamers for wild-type (WT) or mutant sequences are optimized on crystal or nuclear magnetic resonance (NMR) structures prior to template minimization, resulting in alternate structures termed ROM templates. We show that use of ROM templates prepared from sequences known to be stable results predominantly in improved prediction accuracy compared to using the minimized crystal or NMR structures. Conversely, ROM templates prepared from sequences that are less stable than the WT reduce prediction accuracy by increasing the number of false positives. These observed changes in prediction outcomes are attributed to differences in side-chain contacts made by rotamers in ROM templates. Finally, we show that ROM templates prepared from sequences that are unfolded or that adopt a nonnative fold result in the selective enrichment of sequences that are also unfolded or that adopt a nonnative fold, respectively. Our results demonstrate the existence of a rotamer bias caused by the input template that can be harnessed to skew predictions toward sequences displaying desired characteristics. © 2014 The Protein Society.

  4. Construction of energy-stable projection-based reduced order models

    DOE PAGES

    Kalashnikova, Irina; Barone, Matthew F.; Arunajatesan, Srinivasan; ...

    2014-12-15

    Our paper aims to unify and extend several approaches for building stable projection-based reduced order models (ROMs) using the energy method and the concept of “energy-stability”. Attention is focused on linear time-invariant (LTI) systems. First, an approach for building energy stable Galerkin ROMs for linear hyperbolic or incompletely parabolic systems of partial differential equations (PDEs) using continuous projection is proposed. The key idea is to apply to the system a transformation induced by the Lyapunov function for the system, and to build the ROM in the transformed variables. The result of this procedure will be a ROM that is energy-stablemore » for any choice of reduced basis. It is shown that, for many PDE systems, the desired transformation is induced by a special inner product, termed the “symmetry inner product”. Next, attention is turned to building energy-stable ROMs via discrete projection. A discrete counterpart of the continuous symmetry inner product, termed the “Lyapunov inner product”, is derived. Moreover, it is shown that the Lyapunov inner product can be computed in a black-box fashion for a stable LTI system ari sing from the discretization of a system of PDEs in space. Projection in this inner product guarantees a ROM that is energy-stable, again for any choice of reduced basis. Connections between the Lyapunov inner product and the inner product induced by the balanced truncation algorithm are made. We also made comparisons between the symmetry inner product and the Lyapunov inner product. Performance of ROMs constructed using these inner products is evaluated on several benchmark test cases.« less

  5. Characterizing the recovery trajectories of knee range of motion for one year after total knee replacement.

    PubMed

    Mehta, Saurabh; Rigney, Andrew; Webb, Kyle; Wesney, Jacob; Stratford, Paul W; Shuler, Franklin D; Oliashirazi, Ali

    2018-06-13

    Retrospective analysis of routinely collected clinical data. This study modeled the recovery in knee flexion and extension range of motion (ROM) over 1 year after total knee replacement (TKR). Recovery after TKR has been characterized for self-reported pain and functional status. Literature describing target knee ROM at different follow-up periods after TKR is scarce. Data were extracted for patients who had undergone TKR at a tertiary care hospital at 2, 8, 12, 26, and 52 weeks after TKR. A linear mixed-effects growth model was constructed that investigated the following covariates age, sex, pre-TKR range, body mass index, duration of symptoms, and their interaction with weeks post TKR. Of the 559 patients included (age 64.8 ± 8.5 years), 370 were women and 189 were men. Knee ROM showed the greatest change during the first 12 weeks after TKR, plateauing by 26 weeks. For an average patient, knee flexion increased from approximately 100º 2 weeks post TKR to 117º 52 weeks post TKR. Knee extension increased from approximately 3º knee flexion 2 weeks post TKR to 1º flexion 52 weeks post TKR. The results showed that the maximum gains in knee ROM should be expected within the first 12 weeks with small changes occurring up to 26 weeks after TKR. In addition, age and presurgery knee ROM are associated with the gains in knee ROM and should be factored into the estimation of expected knee ROM at a given follow-up interval after TKR.

  6. Clinical application of a gadolinium-based capsule as an MRI contrast agent in slow transit constipation diagnostics.

    PubMed

    Zhi, M; Zhou, Z; Chen, H; Xiong, F; Huang, J; He, H; Zhang, M; Su, M; Gao, X; Hu, P

    2017-06-01

    As a traditional method for the assessment of colon dynamics, radio-opaque markers (ROMs) are limited in clinical use because of their ionizing radiation. We compared the accuracy and applicability of gadolinium-based capsules with ROMs in the measurement of colon dynamics in healthy controls and slow transit constipation (STC) patients. Seven patients with STC and nine healthy controls under a normal diet orally consumed ROMs and gadolinium-based capsules simultaneously. All subjects underwent X-ray and magnetic resonance imaging (MRI). Healthy control images were acquired at 12, 24, and 48 h, and STC patient images were acquired at 24, 48, and 72 h. The scores based on the position of the labeling capsules and ROMs in the colon and the colon transit times (CTTs) in the two groups were compared. The CTTs obtained via the ROMs were 34.7±17.4 and 67.3±6.5 h in the healthy controls and STC patients, respectively (P<.05). The CTTs obtained via MRI were 30.9±15.9 and 74.1±7.2 h in the healthy controls and STC patients, respectively (P<.05). The CTTs of the STC patients were significantly longer than the healthy controls. The correlation (r s ) between the scores based on the position of the labeling capsule and ROMs in the healthy group and the STC patients was .880 (P<.05) and .889 (P<.05), respectively. As a MRI contrast label, gadolinium-based capsules exhibit results comparable to ROMs in colon motility measurements. © 2017 John Wiley & Sons Ltd.

  7. Evaluation of a Shoulder Injury Prevention Program in Wheelchair Basketball.

    PubMed

    Wilroy, Jereme; Hibberd, Elizabeth

    2017-11-15

    Previous literature has theorized that alterations in shoulder physical characteristics are present in wheelchair athletes and contribute to shoulder pain and injury. Limited empirical evidence is present that evaluates the effectiveness of a shoulder injury prevention program focusing on improving these altered characteristics. To evaluate the effectiveness of a 6-week intervention program at improving characteristics that increases the risk of developing pain or shoulder injury. Pre and post-test. Home-based and controlled laboratory. Seven collegiate wheelchair athletes. Shoulder range of motion (ROM) and scapular muscle strength were assessed, and a 5-minute injury prevention program was taught to participants. Participants completed the intervention 3 times per week for 6 weeks. Following completion of the program, a post-intervention screening was performed. Internal/external rotation ROM, retraction strength, and internal/external rotation strength. Participants experienced a significant improvement in dominant limb shoulder internal rotation ROM (t6=3.56,p=0.012) with an average increase of 11.4° of IR ROM, and a significant improvement in dominant limb shoulder external rotation (ER) ROM (t6=2.79,p=0.032) with an average increase of 8.0° of ER ROM. There were no significant increases in shoulder IR or ER strength and scapular retraction strength (p>0.05). Improvements in ROM have previously been linked to decreases in shoulder pain and injury in other upper-extremity dominant sports by improving scapular kinematics. These results provide evidence that a 6-week strengthening and stretching intervention program may decrease risk factors for shoulder injury in wheelchair athletics.

  8. Effects of using human patient simulator versus a CD-ROM on learning the management of patients exposed to chemical agents.

    PubMed

    Johnson, Don; Flagg, Amanda; Dremsa, Theresa L

    2010-01-01

    Very little prospective, randomized, experimental research exists on the use of simulation as a teaching method, and no studies have compared the effects of 2 strategies of using the Human Patient Simulator (HPS) and a CD-ROM on the management of patients exposed to chemical agents. A prospective, pretest-posttest experimental, mixed design (within and between) was used to determine if there were statistically significant differences between educational strategies using HPS, CD-ROM, and a control group in the care of patients exposed to chemical agents. Care was operationally defined as the score on the Management of Chemical Warfare Patients Performance (MCWPP) instrument. Participants included active duty and reserve military nurses (n=92). They were randomly assigned to one of 3 teaching groups: HPS (n=30), CD-ROM (n=31), or a control group (n=31). Analysis of variance and a Tukey post-hoc test were used to analyze the data. The means on MCWPP instrument were as follows: HPS (pretest: mean=65.13, SD ± 8.9; posttest mean=73.0, SD ± 8.6); CD-ROM (pretest: mean=67.74, SD ± 11.18, posttest mean=65.67, SD ± 10.82); control (pretest: mean=68.51 SD ± 8.5; posttest mean=62.6, SD ± 8.6). There were no significant differences between the groups on the pretest (P=.363), but there were significant differences on the posttest (P=.001). Post-hoc analyses indicated the HPS group performed better than the CD-ROM group (P=.017) and the control group (P=.000). There was no significant difference between the CD-ROM and control groups (P=.485). Based on the results of this study, the HPS is more effective than the CD-ROM in teaching nurses about the care of patients exposed to chemical agents.

  9. ACUTE EFFECTS OF DIFFERENT ANTERIOR THIGH SELF-MASSAGE ON HIP RANGE-OF-MOTION IN TRAINED MEN.

    PubMed

    Monteiro, Estêvão Rios; Vigotsky, Andrew D; Novaes, Jefferson da Silva; Škarabot, Jakob

    2018-02-01

    Self-massage is a ubiquitous intervention similar to massage, but performed by the recipient him- or herself rather than by a therapist, most often using a tool (e.g., foam roller, roller massager). Self-massage has been found to have a wide range of effects. It is particularly known for increasing flexibility acutely, although not always. The variability of the results in previous studies may potentially be a function of the tool used. Recent findings also suggest that self-massage exerts global effects. Therefore, increased flexibility should be expected in the areas adjacent to the ones treated. To investigate the acute effects of foam rolling and rolling massage of anterior thigh on hip range-of-motion (ROM) - i.e., hip extension and hip flexion - in trained men. Eighteen recreationally active, resistance trained males visited the lab on two occasions over a 4-day period separated by at least a day. Each session included two baseline ROM measures of passive hip flexion and extension taken in a randomized fashion. Recording of baseline measures was followed by the intervention of the day, which was either foam rolling or rolling massage of the anterior thigh as per randomization. Immediately post intervention, passive hip flexion and hip extension ROM were reassessed. In order to assess the time course of improvements in ROM, hip flexion and hip extension ROM were reevaluated at 10, 20, and 30 minutes post-intervention. Hip flexion and hip extension ROM increased immediately following both interventions (foam rolling or roller massager) and remained increased for 30 minutes post intervention. Foam rolling was statistically superior in improving hip flexion and hip extension ROM immediately post intervention. However, immediately post-intervention was the only time point that measurements exceeded the minimum detectable change for both interventions. Both foam rolling and rolling massage appear to be effective interventions for improving hip flexion and extension ROM when applied to the anterior thigh, but the observed effects are transient in nature. 2b.

  10. A normative study of cervical range of motion measures including the flexion-rotation test in asymptomatic children: side-to-side variability and pain provocation.

    PubMed

    Budelmann, Kim; von Piekartz, Harry; Hall, Toby

    2016-09-01

    Cervical movement impairment has been identified as a core component of cervicogenic headache evaluation. However, normal range of motion values in children has been investigated rarely and no study has reported such values for the flexion-rotation test (FRT). The purpose of this study was to identify normal values and side-to-side variation for cervical spine range of motion (ROM) and the FRT, in asymptomatic children aged 6-12 years. Another important purpose was to identify the presence of pain during the FRT. Thirty-four asymptomatic children without history of neck pain or headache (26 females and 8 males, mean age 125.38 months [SD 13.14]) were evaluated. Cervical spine cardinal plane ROM and the FRT were evaluated by a single examiner using a cervical ROM device. Values for cardinal plane ROM measures are presented. No significant gender difference was found for any ROM measure. Mean difference in ROM for rotation, side flexion, and the FRT were less than one degree. However, intra-individual variation was greater, with lower bound scores of 9.32° for rotation, 5.30° for side flexion, and 10.89° for the FRT. Multiple linear regression analysis indicates that movement in the cardinal planes only explains 19% of the variance in the FRT. Pain scores reported following the FRT were less than 2/10. Children have consistently greater cervical spine ROM than adults. In children, side-to-side variation in rotation and side flexion ROM and range recorded during the FRT indicates that the clinician should be cautious when using range in one direction to determine impairment in another. Range recorded during the FRT is independent of cardinal movement variables, which further adds to the importance of the FRT, as a test that mainly evaluates range of movement of the upper cervical spine.

  11. Effectiveness of Manual Therapy and Stretching for Baseball Players With Shoulder Range of Motion Deficits.

    PubMed

    Bailey, Lane B; Thigpen, Charles A; Hawkins, Richard J; Beattie, Paul F; Shanley, Ellen

    Baseball players displaying deficits in shoulder range of motion (ROM) are at increased risk of arm injury. Currently, there is a lack of consensus regarding the best available treatment options to restore shoulder ROM. Instrumented manual therapy with self-stretching will result in clinically significant deficit reductions when compared with self-stretching alone. Controlled laboratory study. Shoulder ROM and humeral torsion were assessed in 60 active baseball players (mean age, 19 ± 2 years) with ROM deficits (nondominant - dominant, ≥15°). Athletes were randomly assigned to receive a single treatment of instrumented manual therapy plus self-stretching (n = 30) or self-stretching only (n = 30). Deficits in internal rotation, horizontal adduction, and total arc of motion were compared between groups immediately before and after a single treatment session. Treatment effectiveness was determined by mean comparison data, and a number-needed-to-treat (NNT) analysis was used for assessing the presence of ROM risk factors. Prior to intervention, players displayed significant ( P < 0.001) dominant-sided deficits in internal rotation (-26°), total arc of motion (-18°), and horizontal adduction (-17°). After the intervention, both groups displayed significant improvements in ROM, with the instrumented manual therapy plus self-stretching group displaying greater increases in internal rotation (+5°, P = 0.010), total arc of motion (+6°, P = 0.010), and horizontal adduction (+7°, P = 0.004) compared with self-stretching alone. For horizontal adduction deficits, the added use of instrumented manual therapy with self-stretching decreased the NNT to 2.2 (95% CI, 2.1-2.4; P = 0.010). Instrumented manual therapy with self-stretching significantly reduces ROM risk factors in baseball players with motion deficits when compared with stretching alone. The added benefits of manual therapy may help to reduce ROM deficits in clinical scenarios where stretching alone is ineffective.

  12. Effects of Febuxostat on Oxidative Stress.

    PubMed

    Fukui, Toshiki; Maruyama, Mie; Yamauchi, Kazuhiro; Yoshitaka, Sumie; Yasuda, Tadashi; Abe, Youichi

    2015-07-01

    We previously examined factors that affect the measured derivatives of reactive oxygen metabolites (d-ROMs), an indicator of reactive oxygen species production, and biological antioxidant potential (BAP), an indicator of antioxidant capacity, in typical health checkup examinees and reported the usefulness of measuring both indicators simultaneously. In addition, a positive correlation reportedly exists between d-ROMs and the visceral fat area measured by using computed tomography. A recent study of the relationship between uric acid levels and various obesity-related factors found that visceral fat was the factor most strongly related to uric acid levels. Uric acid is itself a potent endogenous antioxidant, but because reactive oxygen species are produced during uric acid generation, it is suggested that uric acid may have opposing effects. The objective of this study was to analyze the effect of febuxostat, a novel xanthine oxidase inhibitor, on oxidative stress. Study subjects were 43 hyperuricemia outpatients receiving care in the internal medicine department of our institution. The subjects were divided into a new administration group (29 patients) and a switched administration group (14 patients); the latter were allopurinol-treated patients with hyperuricemia who were switched to febuxostat. In addition to measuring the patients' uric acid and creatinine levels and estimated glomerular filtration rate before and after treatment, their d-ROMs and BAP as well as the BAP/d-ROMs ratio were also measured. Both groups exhibited significant decreases in uric acid levels, as well as significant decreases in d-ROMs and BAP. No significant changes were observed in the BAP/dROMs ratio or renal function, including creatinine levels and estimated glomerular filtration rate. Febuxostat could significantly reduce d-ROMs. However, BAP levels were also significantly reduced concurrently. No changes were observed in the BAP/d-ROMs ratios. This regulatory mechanism is believed to have counteracted changes in the in vivo oxidative stress balance caused by febuxostat administration. Copyright © 2015 Elsevier HS Journals, Inc. All rights reserved.

  13. Neck arthritis pain is reduced and range of motion is increased by massage therapy.

    PubMed

    Field, Tiffany; Diego, Miguel; Gonzalez, Gladys; Funk, C G

    2014-11-01

    The literature on the effects of massage therapy on neck arthritis pain is mixed depending on the dose level, and it is also based on self-report. In the present study an attempt was made to enhance the effects of weekly massage therapy by having the participants massage themselves daily. And in addition to self-reports on pain, range of motion (ROM) and the associated ROM pain were assessed before and after the first massage session and pre-post the last session one month later. Staff and faculty members at a medical school who were eligible for the study if they had neck arthritis pain were randomly assigned to a massage or a waitlist control group (N = 24 per group). The massage group received moderate pressure massages weekly by a massage therapist plus daily self-massages. The waitlist control group received the same schedule massages one month after being control subjects. The massage group showed significant short-term reductions after the first and last day massages in self-reported pain and in ROM-associated pain as well as an increase in ROM. Comparisons between the massage group (N = 23) and the control group (N = 14) on the last versus the first day data suggested significantly different changes including increased ROM and reduced ROM-associated pain for the massage group and reduced ROM and increased ROM-associated pain for the control group. These changes occurred specifically for flexion and right and left lateral flexion motions. These data highlight the importance of designing massage therapy protocols that target the most affected neck muscle groups and then assessing range of motion and related pain before and after the massage therapy. Comparisons with other studies also suggest that moderate pressure may contribute to the massage effects, and the use of daily self-massages between sessions may sustain the effects and serve as a cost-effective therapy for individuals with neck arthritis pain. Copyright © 2014. Published by Elsevier Ltd.

  14. Artificial Disk Replacement Combined With Fusion Versus 2-Level Fusion in Cervical 2-Level Disk Disease With a 5-Year Follow-up.

    PubMed

    Ji, Gyu Yeul; Oh, Chang Hyun; Shin, Dong Ah; Ha, Yoon; Yi, Seong; Kim, Keung Nyun; Shin, Hyun Cheol; Yoon, Do Heum

    2017-06-01

    Prospective study. The purpose of this study was to compare the long-term clinical and radiologic outcomes of hybrid surgery (HS) and 2-level anterior cervical discectomy and fusion (2-ACDF) in patients with 2-level cervical disk disease. In a previous study with a 2-year follow-up, HS was shown to be superior to 2-ACDF, with a better Neck Disability Index (NDI) score, less postoperative neck pain, faster C2-C7 range of motion (ROM) recovery, and less adjacent ROM increase. Between 2004 and 2006, 40 patients undergoing 2-level cervical disk surgery at our hospital were identified as 2-level degenerative disk disease. Forty patients were included in the previous study; 35 patients were followed up for 5 years. Patients completed the NDI and graded their pain intensity before surgery and at routine postoperative until 5 years. Dynamic cervical radiographs were obtained before surgery and at routine postoperative intervals and the angular ROM for C2-C7 and adjacent segments was measured. The HS group had better NDI recovery until 3 years after surgery (P<0.05). Postoperative neck pain was lower in the HS group at 1 and 3 years after surgery (P<0.05), but arm pain relief was not differently relieved. The HS group showed more angular ROM for C2-C7 at 2 and 3 years after surgery. The superior adjacent segment ROM showed hypermobility in the 2-ACDF group and hypomobility in the HS group at all follow-up periods without statistically significance, but the inferior adjacent segment ROM differed significantly (P<0.05). HS is superior to 2-ACDF; it leads to better NDI recovery, less postoperative neck pain, faster C2-C7 ROM recovery, and less adjacent ROM increase over a 2-year follow-up, but these benefits of HS become similar to those of 2-ACDF with 5 years of follow-up.

  15. Validation of the All Patient Refined Diagnosis Related Group (APR-DRG) Risk of Mortality and Severity of Illness Modifiers as a Measure of Perioperative Risk.

    PubMed

    McCormick, Patrick J; Lin, Hung-Mo; Deiner, Stacie G; Levin, Matthew A

    2018-03-22

    The All Patient Refined Diagnosis Related Group (APR-DRG) is an inpatient visit classification system that assigns a diagnostic related group, a Risk of Mortality (ROM) subclass and a Severity of Illness (SOI) subclass. While extensively used for cost adjustment, no study has compared the APR-DRG subclass modifiers to the popular Charlson Comorbidity Index as a measure of comorbidity severity in models for perioperative in-hospital mortality. In this study we attempt to validate the use of these subclasses to predict mortality in a cohort of surgical patients. We analyzed all adult (age over 18 years) inpatient non-cardiac surgery at our institution between December 2005 and July 2013. After exclusions, we split the cohort into training and validation sets. We created prediction models of inpatient mortality using the Charlson Comorbidity Index, ROM only, SOI only, and ROM with SOI. Models were compared by receiver-operator characteristic (ROC) curve, area under the ROC curve (AUC), and Brier score. After exclusions, we analyzed 63,681 patient-visits. Overall in-hospital mortality was 1.3%. The median number of ICD-9-CM diagnosis codes was 6 (Q1-Q3 4-10). The median Charlson Comorbidity Index was 0 (Q1-Q3 0-2). When the model was applied to the validation set, the c-statistic for Charlson was 0.865, c-statistic for ROM was 0.975, and for ROM and SOI combined the c-statistic was 0.977. The scaled Brier score for Charlson was 0.044, Brier for ROM only was 0.230, and Brier for ROM and SOI was 0.257. The APR-DRG ROM or SOI subclasses are better predictors than the Charlson Comorbidity Index of in-hospital mortality among surgical patients.

  16. [Does routine outcome monitoring have a promising future? An investigation into the use of shared decision-making combined with ROM for patients with a combination of physical and psychiatric symptoms].

    PubMed

    van der Feltz-Cornelis, C M; Andrea, H; Kessels, E; Duivenvoorden, H J; Biemans, H; Metz, M

    2014-01-01

    Although routine outcome monitoring (ROM) has been developed and widely used in the course of patient centered outcome research in the Netherlands, so far the technique has hardly ever been used to improve the treatment of individual patients. To describe how a rom technique based on the principles of shared decision-making (SDM) was developed and evaluated at the Center for Body, Mind and Health at GGz Breburg, a specialised mental health institution in the Netherlands. We have developed a conceptual model for SDM that involves patient participation and the use of evidence-based decision-aids with cut-off scores. According to the conceptual model for SDM that we developed, the patient and the health professional involved took 'shared' decisions in three phases; the decisions related to triage, the drawing-up of a treatment plan and a follow-up treatment course. At the end of the 6 month intake-phase 7 of the 67 patients who were deemed eligible for ROM/SDM were dropped from the study because they were incapable of performing ROM assessments. Due to diagnostic advice and referral at the end of the intake-phase, 25 patients did not require further treatment. Of the remaining 35 patients, 33 delivered at least one follow-up ROM assessment during the subsequent treatment phases. In these patients somatic and psychiatric symptoms were found to be significantly reduced. ROM combined with sdm can be used successfully with patients who have a combination of physical and psychiatric symptoms and the technique can be applied by the professional in charge. Very few patients dropped out of the follow-up measurements and somatic as well as depressive or psychiatric symptoms diminished significantly. These findings indicate that a Randomised Clinical Trial is warranted in order to test the effectiveness of sdm combined with ROM as a decision-making instrument.

  17. Normal values of reactive oxygen metabolites on the cord-blood of full-term infants with a colorimetric method.

    PubMed

    Parmigiani, S; Payer, C; Massari, A; Bussolati, G; Bevilacqua, G

    2000-01-01

    The main end-point of the study was to evaluate the normal values of reactive oxygen metabolites (ROMs) in healthy full-term babies. Secondary end-points were differences between groups related to modality of delivery, Apgar score, birth weight, gestational age and sex. All apparently healthy babies born at our institution between 8 a.m. and 8 p.m. Monday to Friday with gestational age 37-42 weeks, delivered both vaginally or by caesarean section and without foetal distress and perinatal asphyxia. ROMs were evaluated by a colorimetric method (d-ROM test) on cord-blood immediately after birth. The values are reported as arbitrary unit U. Carr. Statistical analysis was performed by t-test and by multiple and stepwise regression analysis. We have analyzed 80 babies with mean birth weight 3301 +/- 446 g. and mean gestational age 39.5 +/- 1.0 weeks. The male:female ratio was 1.56 and the median (range) Apgar score was 9 (7-10) at 1' and 10 (9-10) at 5'. The babies born by vaginal delivery were 37 out of 80 while the remaining 43 were delivered by cesarean section. Because the two groups did not differ for the clinical characteristics they were considered together for the determination of the mean value of ROMs and indicated as "total". The mean value +/- SD of ROMs of the "total" was 115.5 +/- 32.6 U. Carr. Significant differences in the mean value of ROMs were not found related to type of delivery, birth weight, gestational age, and Apgar score at 1' and 5'. Instead the female infants had a significantly lower mean value of ROMs than the male babies (respectively 104.4 +/- 32.2 vs 120.2 +/- 30.6 U. Carr.; p = 0.031). Multiple and stepwise regression analyses both demonstrated that the sex of the neonate is able to independently influence the value of ROMs (respectively p = 0.025 and p = 0.035). The main end-point of the study was to determine the standard reference values for this method in the healthy full-term infant at birth: the values of ROMs we found in the "total" population are lower than those of healthy adults (between 250-300 U. Carr.) and similar to those of adults treated with steroids or antioxidant drugs. The finding that the female sex is able to independently determine lower values of ROMs at birth compared to the male sex, lets speculate that the female infants are less prone to oxidative stress in the first moments of life.

  18. Modeling impairment: using the disablement process as a framework to evaluate determinants of hip and knee flexion.

    PubMed

    Lichtenstein, M J; Dhanda, R; Cornell, J E; Escalante, A; Hazuda, H P

    2000-06-01

    Elders often present to health care providers with multiple inter-related conditions that determine an individual's ability to function. The disablement process provides a generalized sociomedical framework for investigating the complex pathways from chronic disease to disability. At each stage of the main pathway, associations may exist among primary physical factors and modifying variables that ultimately have downstream effects on the progression toward disability. The purpose of the present analysis is to examine the inter-relationships between a cohesive set of variables primarily at the level of impairment that may affect hip and knee flexion range of motion (ROM). The San Antonio Longitudinal Study of Aging enrolled 833 community dwelling Mexican (MA) and European American (EA) elders aged 64-78 years between 1992 and 1996. Of these, 647 had complete data from both a home-based and performance-based battery of assessments for these analyses. Concerning impairments, hip ROM was measured using an inclinometer, and knee ROM using a goniometer. Pain location and intensity were assessed using the McGill Pain Questionnaire. Peripheral vascular disease was assessed using doppler brachial and ankle systolic blood pressures. Ankle and knee reflexes, and vibratory sensation were assessed by a standardized neurological examination. As to diseases, diabetes was assessed using a combination of blood glucose levels and self-report, and arthritis by self-report. Concerning modifying variables, height and weight were directly measured and used to calculate BMI. Activity level was assessed with the Minnesota Leisure Time Questionnaire. Analgesic use was assessed by direct observation of medications taken within the past two weeks. We used structural equation modeling to test associations between the variables that were specified a priori. These analyses demonstrate the central role of BMI as a determinant of hip and knee flexion ROM. For an increase in level of BMI, the coefficients [SEM] for changes in levels of hip and knee ROM were -0.38 [0.05] and -0.26 [0.05], respectively. A higher BMI resulted in lower hip and knee ROM. BMI was also directly associated with prevalent diabetes (0.10 [0.05]) and arthritis (0.17 [0.05]). However, after adjustment for BMI, diabetes and arthritis did not have direct independent associations with either hip or knee ROM. BMI was also indirectly associated with knee, but not hip, ROM through paths including lower-leg pain, pain intensity, and neurosensory impairments. Diabetes had an indirect association with hip, but not knee ROM, through a path including peripheral vascular disease. In conclusion, BMI is a primary direct determinant of hip and knee ROM. The paths by which diabetes and arthritis lead to physical disability may be mediated, in part, at the level of impairment by BMI's association with joint range of motion. Interventions designed to decrease the impact of diabetes and arthritis on disability should track changes in BMI and joint ROM to measure the paths that account for the intervention's success. The observed associations suggest that interventions targeted to decrease BMI itself may lead to improved function in part through improved joint ROM.

  19. Risk Factors for Medial Tibial Stress Syndrome in Active Individuals: An Evidence-Based Review.

    PubMed

    Winkelmann, Zachary K; Anderson, Dustin; Games, Kenneth E; Eberman, Lindsey E

    2016-12-01

    Reference/Citation: Hamstra-Wright KL, Bliven KC, Bay C. Risk factors for medial tibial stress syndrome in physically active individuals such as runners and military personnel: a systematic review and meta-analysis. Br J Sports Med. 2015;49(6):362-369. What factors put physically active individuals at risk to develop medial tibial stress syndrome (MTSS)? The authors performed a literature search of CINAHL, the Cochrane Central Register of Controlled Trials, EMBASE, and MEDLINE from each database's inception to July 2013. The following key words were used together or in combination: armed forces, athlete, conditioning, disorder predictor, exercise, medial tibial stress syndrome, militaries, MTSS, military, military personnel, physically active, predictor, recruit, risk, risk characteristic, risk factor, run, shin pain, shin splints, and vulnerability factor. Studies were included in this systematic review based on the following criteria: original research that (1) investigated risk factors associated with MTSS, (2) compared physically active individuals with and without MTSS, (3) was printed in English, and (4) was accessible in full text in peer-reviewed journals. Two authors independently screened titles or abstracts (or both) of studies to identify inclusion criteria and quality. If the article met the inclusion criteria, the authors extracted demographic information, study design and duration, participant selection, MTSS diagnosis, investigated risk factors, mean difference, clinical importance, effect size, odds ratio, and any other data deemed relevant. After the data extraction was complete, the authors compared findings for accuracy and completeness. When the mean and standard deviation of a particular risk factor were reported 3 or more times, that risk factor was included in the meta-analysis. In addition, the methodologic quality was assessed with an adapted checklist developed by previous researchers. The checklist contained 5 categories: study objective, study population, outcome measurements, assessment of the outcome, and analysis and data presentation. Any disagreement between the authors was discussed and resolved by consensus. A total of 165 papers were initially identified, and 21 original research studies were included in this systematic review. More than 100 risk factors were identified in the 21 studies. Continuous data were reported 3 or more times for risk factors of body mass index (BMI), navicular drop, ankle plantar-flexion range of motion (ROM), ankle-dorsiflexion ROM, ankle-eversion ROM, ankle-inversion ROM, quadriceps angle, hip internal-rotation ROM, and hip external-rotation ROM. As compared with the control group, significant risk factors for developing MTSS identified in the literature were (1) greater BMI (mean difference [MD] = 0.79, 95% confidence interval [CI] = 0.38, 1.20; P < .001), (2) greater navicular drop (MD = 1.9 mm, 95% CI = 0.54, 1.84 mm; P < .001), (3) greater ankle plantar-flexion ROM (MD = 5.94°, 95% CI = 3.65°, 8.24°; P < .001), and (4) greater hip external-rotation ROM (MD = 3.95°, 95% CI = 1.78°, 6.13°; P < .001). Ankle-dorsiflexion ROM (MD = -0.01°, 95% CI = -0.96, 0.93; P = .98), ankle-eversion ROM (MD = 1.17°, 95% CI = -0.02, 2.36; P = .06), ankle-inversion ROM (MD = 0.98°, 95% CI = -3.11°, 5.07°; P = .64), quadriceps angle (MD = -0.22°, 95% CI = -0.95°, 0.50°; P = .54), and hip internal-rotation ROM (MD = 0.18°, 95% CI = -5.37°, 5.73°; P = .95), were not different between individuals with MTSS and controls. The primary factors that appeared to put a physically active individual at risk for MTSS were increased BMI, increased navicular drop, greater ankle plantar-flexion ROM, and greater hip external-rotation ROM. These primary risk factors can guide health care professionals in the prevention and treatment of MTSS.

  20. Risk Factors for Medial Tibial Stress Syndrome in Active Individuals: An Evidence-Based Review

    PubMed Central

    Winkelmann, Zachary K.; Anderson, Dustin; Games, Kenneth E.; Eberman, Lindsey E.

    2016-01-01

    Reference/Citation: Hamstra-Wright KL, Bliven KC, Bay C. Risk factors for medial tibial stress syndrome in physically active individuals such as runners and military personnel: a systematic review and meta-analysis. Br J Sports Med. 2015;49(6):362–369. Clinical Question: What factors put physically active individuals at risk to develop medial tibial stress syndrome (MTSS)? Data Sources: The authors performed a literature search of CINAHL, the Cochrane Central Register of Controlled Trials, EMBASE, and MEDLINE from each database's inception to July 2013. The following key words were used together or in combination: armed forces, athlete, conditioning, disorder predictor, exercise, medial tibial stress syndrome, militaries, MTSS, military, military personnel, physically active, predictor, recruit, risk, risk characteristic, risk factor, run, shin pain, shin splints, and vulnerability factor. Study Selection: Studies were included in this systematic review based on the following criteria: original research that (1) investigated risk factors associated with MTSS, (2) compared physically active individuals with and without MTSS, (3) was printed in English, and (4) was accessible in full text in peer-reviewed journals. Data Extraction: Two authors independently screened titles or abstracts (or both) of studies to identify inclusion criteria and quality. If the article met the inclusion criteria, the authors extracted demographic information, study design and duration, participant selection, MTSS diagnosis, investigated risk factors, mean difference, clinical importance, effect size, odds ratio, and any other data deemed relevant. After the data extraction was complete, the authors compared findings for accuracy and completeness. When the mean and standard deviation of a particular risk factor were reported 3 or more times, that risk factor was included in the meta-analysis. In addition, the methodologic quality was assessed with an adapted checklist developed by previous researchers. The checklist contained 5 categories: study objective, study population, outcome measurements, assessment of the outcome, and analysis and data presentation. Any disagreement between the authors was discussed and resolved by consensus. Main Results: A total of 165 papers were initially identified, and 21 original research studies were included in this systematic review. More than 100 risk factors were identified in the 21 studies. Continuous data were reported 3 or more times for risk factors of body mass index (BMI), navicular drop, ankle plantar-flexion range of motion (ROM), ankle-dorsiflexion ROM, ankle-eversion ROM, ankle-inversion ROM, quadriceps angle, hip internal-rotation ROM, and hip external-rotation ROM. As compared with the control group, significant risk factors for developing MTSS identified in the literature were (1) greater BMI (mean difference [MD] = 0.79, 95% confidence interval [CI] = 0.38, 1.20; P < .001), (2) greater navicular drop (MD = 1.9 mm, 95% CI = 0.54, 1.84 mm; P < .001), (3) greater ankle plantar-flexion ROM (MD = 5.94°, 95% CI = 3.65°, 8.24°; P < .001), and (4) greater hip external-rotation ROM (MD = 3.95°, 95% CI = 1.78°, 6.13°; P < .001). Ankle-dorsiflexion ROM (MD = −0.01°, 95% CI = −0.96, 0.93; P = .98), ankle-eversion ROM (MD = 1.17°, 95% CI = −0.02, 2.36; P = .06), ankle-inversion ROM (MD = 0.98°, 95% CI = −3.11°, 5.07°; P = .64), quadriceps angle (MD = −0.22°, 95% CI = −0.95°, 0.50°; P = .54), and hip internal-rotation ROM (MD = 0.18°, 95% CI = −5.37°, 5.73°; P = .95), were not different between individuals with MTSS and controls. Conclusions: The primary factors that appeared to put a physically active individual at risk for MTSS were increased BMI, increased navicular drop, greater ankle plantar-flexion ROM, and greater hip external-rotation ROM. These primary risk factors can guide health care professionals in the prevention and treatment of MTSS. PMID:27835043

Top